Sample records for tamper indicating devices

  1. Triboluminescent tamper-indicating device

    DOEpatents

    Johnston, Roger G.; Garcia, Anthony R. E.

    2002-01-01

    A tamper-indicating device is described. The device has a transparent or translucent cylindrical body that includes triboluminescent material, and an outer opaque layer that prevents ambient light from entering. A chamber in the body holds an undeveloped piece of photographic film bearing an image. The device is assembled from two body members. One of the body members includes a recess for storing film and an optical assembly that can be adjusted to prevent light from passing through the assembly and exposing the film. To use the device with a hasp, the body members are positioned on opposite sides of a hasp, inserted through the hasp, and attached. The optical assembly is then manipulated to allow any light generated from the triboluminescent materials during a tampering activity that damages the device to reach the film and destroy the image on the film.

  2. Tamper-indicating device having a glass body

    DOEpatents

    Johnston, Roger G.; Garcia, Anthony R. E.

    2003-04-29

    A tamper-indicating device is described. The device has a first glass body member and a second glass body member that are attached to each other through a hasp. The glass body members of the device can be tempered. The body members can be configured with hollow volumes into which powders, microparticles, liquids, gels, or combinations thereof are sealed. The choice, the amount, and the location of these materials can produce a visible, band pattern to provide each body member with a unique fingerprint identifier, which makes it extremely difficult to repair or replace once it is damaged in order to avoid tamper detection.

  3. Tamper Indicating Device: Initial Training, Course 50112

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bonner, Stephen Ray; Sandoval, Dana M.

    Tamper Indicating Device (TID): Initial Training, course #50112, covers Los Alamos National Laboratory (LANL) Material Control & Accountability (MC&A) TID Program procedures for the application and removal of TIDs. LANL’s policy is to comply with Department of Energy (DOE) requirements for the use of TIDs consistent with the graded safeguards described in DOE Manual DOE O 474.2, Nuclear Material Control and Accountability. When you have completed this course, you will: recognize standard practices and procedures of the LANL TID Program; have hands-on experience in the application and removal of LANL TIDs, and; verify the application and removal of LANL TIDs.

  4. Tamper-indicating barcode and method

    DOEpatents

    Cummings, Eric B.; Even, Jr., William R.; Simmons, Blake A.; Dentinger, Paul Michael

    2005-03-22

    A novel tamper-indicating barcode methodology is disclosed that allows for detection of alteration to the barcode. The tamper-indicating methodology makes use of a tamper-indicating means that may be comprised of a particulate indicator, an optical indicator, a deformable substrate, and/or may be an integrated aspect of the barcode itself. This tamper-indicating information provides greater security for the contents of containers sealed with the tamper-indicating barcodes.

  5. Tamper indicating bolt

    DOEpatents

    Blagin, Sergei V.; Barkanov, Boris P.

    2004-09-14

    A tamper-indicating fastener has a cylindrical body with threads extending from one end along a portion of the body, and a tamper indicating having a transducer for converting physical properties of the body into electronic data; electronics for recording the electronic data; and means for communicating the recorded information to a remote location from said fastener. The electronics includes a capacitor that varies as a function of force applied by the fastener, and non-volatile memory for recording instances when the capacitance varies, providing an indication of unauthorized access.

  6. Tamper-indicating seal

    DOEpatents

    Fiarman, S.; Degen, M.F.; Peters, H.F.

    1982-08-13

    There is disclosed a tamper-indicating seal that permits in the field inspection and detection of tampering. Said seal comprises a shrinkable tube having a visible pattern of markings which is shrunk over th item to be sealed, and a second transparent tube, having a second visible marking pattern, which is shrunk over the item and the first tube. The relationship between the first and second set of markings produces a pattern so that the seal may not be removed without detection. The seal is particularly applicable to UF/sub 6/ cylinder valves.

  7. Tamper indicating gold nanocup plasmonic films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeVetter, Brent M.; Bernacki, Bruce E.; Bennett, Wendy D.

    The spectral signature of nanoplasmonic films are both robust and tailorable with optical responses ranging from the visible to the near-infrared. We present the development of flexible, elastomeric nanoplasmonic films consisting of periodic arrays of gold nanocups as tamper indicating films. Gold nanocups have polarization-sensitive optical properties that may be manufactured into films that offer unique advantages for tamper indication. These flexible films can be made quickly and at low-cost using commercially available monodisperse polystyrene nanospheres through self-assembly followed by plasma etching, metal deposition, and lift-off from a sacrificial substrate. Polarization- and angle-dependent optical spectroscopic measurements were performed to characterizemore » the fabricated films. Furthermore, using polarization-sensitive hyperspectral imaging, we demonstrate how these films can be applied to tamper indication and counterfeit resistance applications.« less

  8. Tamper indicating gold nanocup plasmonic films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeVetter, Brent M.; Bernacki, Bruce E.; Bennett, Wendy D.

    2017-02-13

    The spectral signature of nanoplasmonic films are both robust and tailorable with optical responses ranging from the visible to the near-infrared. We present the development of flexible, elastomeric nanoplasmonic films consisting of periodic arrays of gold nanocups as tamper indicating films. Gold nanocups have polarization-sensitive optical properties that may be manufactured into films that offer unique advantages for tamper indication. These flexible films can be made quickly and at low-cost using commercially available monodisperse polystyrene nanospheres through self-assembly followed by plasma etching, metal deposition, and lift-off from a sacrificial substrate. Polarization- and angle-dependent optical spectroscopic measurements were performed to characterizemore » the fabricated films. Using polarization-sensitive hyperspectral imaging, we demonstrate how these films can be applied to tamper indication and counterfeit resistance applications.« less

  9. Enhanced tamper indicator

    DOEpatents

    Garcia, Anthony R.; Johnston, Roger G.

    2003-07-08

    The present invention provides an apparatus and method whereby the reliability and tamper-resistance of tamper indicators can be improved. A flexible connector may be routed through a latch for an enclosure such as a door or container, and the free ends of the flexible connector may be passed through a first locking member and firmly attached to an insert through the use of one or more attachment members such as set screws. A second locking member may then be assembled in interlocking relation with the first locking member to form an interlocked assembly around the insert. The insert may have one or more sharp projections extending toward the first or second locking member so that any compressive force applied in an attempt to disassemble the interlocked assembly results in permanent, visible damage to the first or second locking member.

  10. Tamper-indicating seals : practices, problems, and standards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnston, R. G.

    2003-01-01

    Tamper-indicating seals have been used by customs officials for over 7,000 years. Today, seals are widely used to help counter theft, smuggling, sabotage, vandalism, terrorism, and espionage. Despite their antiquity and modern widespread use, however, there remains considerable confusion about seals, as well as a lot of misconceptions, wishful thinking, sloppy terminology, and poor practice. The absence of meaningful norms and standards, together with the surprisingly limited amount of research and development (R&D) in the field of tamper detection, has also hindered the effective use of seals. The Vulnerability Assessment Team (VAT) at Los Alamos National Laboratory has intensively studiedmore » tamper-indicating seals for the last 12 years. We have engaged in vulnerability assessments, R&D, consulting, and training for over two dozen United States government agencies and private companies, as well as for the International Atomic Energy Agency (IAEA) and Euratom. The VAT has also analyzed over 200 different types of seals in detail. This paper summarizes some of our conclusions, recommendations, and warnings regarding seals and tamper detection.« less

  11. A tamper-indicating quantum seal

    DOE PAGES

    Williams, Brian P.; Britt, Keith A.; Humble, Travis S.

    2016-01-04

    Technical means for identifying when tampering occurs is a critical part of many containment and surveillance technologies. Conventional fiber optic seals provide methods for monitoring enclosed inventories, but they are vulnerable to spoofing attacks based on classical physics. We address these vulnerabilities with the development of a quantum seal that offers the ability to detect the intercept-resend attack using quantum integrity verification. Our approach represents an application of entanglement to provide guarantees in the authenticity of the seal state by verifying it was transmitted coherently. We implement these ideas using polarization-entangled photon pairs that are verified after passing through amore » fiber-optic channel testbed. Using binary detection theory, we find the probability of detecting inauthentic signals is greater than 0.9999 with a false alarm chance of 10 –9 for a 10 second sampling interval. In addition, we show how the Hong-Ou-Mandel effect concurrently provides a tight bound on redirection attack, in which tampering modifies the shape of the seal. Our measurements limit the tolerable path length change to sub-millimeter disturbances. As a result, these tamper-indicating features of the quantum seal offer unprecedented security for unattended monitoring systems.« less

  12. DEVELOPMENT OF A CERAMIC TAMPER INDICATING SEAL: SRNL CONTRIBUTIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krementz, D.; Brinkman, K.; Martinez-Rodriguez, M.

    2013-06-03

    Savannah River National Laboratory (SRNL) and Sandia National Laboratories (SNL) are collaborating on development of a Ceramic Seal, also sometimes designated the Intrinsically Tamper Indicating Ceramic Seal (ITICS), which is a tamper indicating seal for international safeguards applications. The Ceramic Seal is designed to be a replacement for metal loop seals that are currently used by the IAEA and other safeguards organizations. The Ceramic Seal has numerous features that enhance the security of the seal, including a frangible ceramic body, protective and tamper indicating coatings, an intrinsic unique identifier using Laser Surface Authentication, electronics incorporated into the seal that providemore » cryptographic seal authentication, and user-friendly seal wire capture. A second generation prototype of the seal is currently under development whose seal body is of Low Temperature Co-fired Ceramic (LTCC) construction. SRNL has developed the mechanical design of the seal in an iterative process incorporating comments from the SNL vulnerability review team. SRNL is developing fluorescent tamper indicating coatings, with recent development focusing on optimizing the durability of the coatings and working with a vendor to develop a method to apply coatings on a 3-D surface. SRNL performed a study on the effects of radiation on the electronics of the seal and possible radiation shielding techniques to minimize the effects. SRNL is also investigating implementation of Laser Surface Authentication (LSA) as a means of unique identification of each seal and the effects of the surface coatings on the LSA signature.« less

  13. Using Focus Groups to Study Consumer Understanding and Experiences with Tamper-Evident Packaging Devices

    ERIC Educational Resources Information Center

    Pascall, Melvin A.; Lee, Ken; Fraser, Angela; Halim, Linna

    2009-01-01

    A focus group with an educational component was used to help initiate a new research hypothesis. Early-stage development of a new tamper-evident invention was improved with input from a consumer focus group. The focus group comprised consumers who were shown several tamper-evident devices, including a new color-changing cap under active…

  14. Reusable tamper-indicating security seal

    DOEpatents

    Ryan, Michael J.

    1983-01-01

    The invention teaches means for detecting unauthorized tampering or substitutions of a device, and has particular utility when applied on a "seal" device used to secure a location or thing. The seal has a transparent body wall, and a first indicia, viz., a label identification is formed on the inside surface of this wall. Second and third indicia are formed on the outside surface of the transparent wall, and each of these indicia is transparent to allow the parallax angled viewing of the first indicia through these indicia. The second indicia is in the form of a broadly uniform pattern, viz, many small spaced dots; while the third indicia is in the form of easily memorized objects, such as human faces, made on a substrate by means of halftone printing. The substrate is lapped over the outside surface of the transparent wall. A thin cocoon of a transparent material, generally of the same material as the substrate such as plastic, is formed over the seal body and specifically over the transparent wall and the second and third indicia formed thereon. This cocoon is seamless and has walls of nonuniform thickness. Both the genuineness of the seal and whether anyone has attempted to compromise the seal can thus be visually determined upon inspection.

  15. Optically resonant subwavelength films for tamper-indicating tags and seals

    NASA Astrophysics Data System (ADS)

    Alvine, Kyle J.; Suter, Jonathan D.; Bernacki, Bruce E.; Bennett, Wendy D.

    2015-05-01

    We present the design, modeling and performance of a proof-of-concept tamper indicating approach that exploits newlydeveloped subwavelength-patterned films. These films have a nanostructure-dependent resonant optical reflection that is wavelength, angle, and polarization dependent. As such, they can be tailored to fabricate overlay transparent films for tamper indication and authentication of sensitive or controlled materials not possible with currently-known technologies. An additional advantage is that the unique optical signature is dictated by the geometry and fabrication process of the nanostructures in the film, rather than on the material used. The essential structure unit in the subwavelength resonant coating is a nanoscale Open-Ring Resonator (ORR). This building block is fabricated by coating a dielectric nanoscale template with metal to form a hemispherical shell-like structure. This curved metallic shell structure has a cross-section with an intrinsic capacitance and inductance and is thus the optical equivalent to the well-known "LC" circuit where the capacitance and inductance are determined by the nanoshell dimensions. For structures with sub 100 nm scale, this resonance occurs in the visible electromagnetic spectrum, and in the IR for larger shells. Tampering of the film would be visible though misalignment of the angle-sensitive features in the film. It is additionally possible to add in intrinsic oxidation and strain sensitive matrix materials to further complicate tamper repair and counterfeiting. Cursory standoff readout would be relatively simple using a combination of a near-infrared (or visible) LED flashlight and polarizer or passively using room lighting illumination and a dispersive detector.

  16. System for tamper identification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bobbitt, III, John Thomas; Weeks, George E.

    2017-09-05

    A system for tamper identification. A fastener has a tamper identification surface with a unique grain structure that is altered if the fastener is removed or otherwise exposed to sufficient torque. After a period of time such as e.g., shipment and/or storage of the sealed container, a determination of whether tampering has occurred can be undertaken by examining the grain structure to determine if it has changed since the fastener was used to seal the container or secure the device.

  17. Tamper-indicating quantum optical seals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Humble, Travis S; Williams, Brian P

    2015-01-01

    Confidence in the means for identifying when tampering occurs is critical for containment and surveillance technologies. Fiber-optic seals have proven especially useful for actively surveying large areas or inventories due to the extended transmission range and flexible layout of fiber. However, it is reasonable to suspect that an intruder could tamper with a fiber-optic sensor by accurately replicating the light transmitted through the fiber. In this contribution, we demonstrate a novel approach to using fiber-optic seals for safeguarding large-scale inventories with increased confidence in the state of the seal. Our approach is based on the use of quantum mechanical phenomenamore » to offer unprecedented surety in the authentication of the seal state. In particular, we show how quantum entangled photons can be used to monitor the integrity of a fiber-optic cable - the entangled photons serve as active sensing elements whose non-local correlations indicate normal seal operation. Moreover, we prove using the quantum no-cloning theorem that attacks against the quantum seal necessarily disturb its state and that these disturbances are immediately detected. Our quantum approach to seal authentication is based on physical principles alone and does not require the use of secret or proprietary information to ensure proper operation. We demonstrate an implementation of the quantum seal using a pair of entangled photons and we summarize our experimental results including the probability of detecting intrusions and the overall stability of the system design. We conclude by discussing the use of both free-space and fiber-based quantum seals for surveying large areas and inventories.« less

  18. Active Time Domain Reflectometry for Tamper Indication in Unattended Safeguards Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheen, David M.; Smith, Leon E.; Tedeschi, Jonathan R.

    2015-07-14

    The International Atomic Energy Agency (IAEA) continues to expand its use of unattended measurement systems. An increasing number of systems and an expanding family of instruments create challenges in terms of deployment efficiency and the implementation of data authentication measures. In collaboration with the IAEA, tamper-indicating measures to address data-transmission authentication challenges with unattended safeguards systems are under investigation. Pacific Northwest National Laboratory is studying the viability of active time-domain reflectometry (TDR) along two parallel but interconnected paths: (1) swept-frequency TDR as the highly flexible, laboratory gold standard to which field-deployable options can be compared, and (2) a low-cost commerciallymore » available spread-spectrum TDR technology as one option for field implementation. This paper describes the TDR methods under investigation and the associated benchtop test-bed, tampering scenarios of interest,, and viability measurement results to date (e.g., comparison of relative sensitivity to tamper scenarios).« less

  19. Reusable, tamper-indicating seal

    DOEpatents

    Ryan, Michael J.

    1978-01-01

    A reusable, tamper-indicating seal comprises a drum confined within a fixed body and rotatable in one direction therewithin, the top of the drum constituting a tray carrying a large number of small balls of several different colors. The fixed body contains parallel holes for looping a seal wire therethrough. The base of the drums carries cams adapted to coact with cam followers to lock the wire within the seal at one angular position of the drum. A channel in the fixed body -- visible from outside the seal -- adjacent the tray constitutes a segregated location for a small plurality of the colored balls. A spring in the tray forces colored balls into the segregated location at one angular position of the drum, further rotation securing the balls in position and the wires in the seal. A wedge-shaped plough removes the balls from the segregated location, at a different angular position of the drum, the wire being unlocked at the same position. A new pattern of colored balls will appear in the segregated location when the seal is relocked.

  20. Method and apparatus for active tamper indicating device using optical time-domain reflectometry

    DOEpatents

    Smith, D. Barton; Muhs, Jeffrey D.; Pickett, Chris A.; Earl, D. Duncan

    1999-01-01

    An optical time-domain reflectometer (OTDR) launches pulses of light into a link or a system of multiplexed links and records the waveform of pulses reflected by the seals in the link(s). If a seal is opened, the link of cables will become a discontinuous transmitter of the light pulses and the OTDR can immediately detect that a seal has been opened. By analyzing the waveform, the OTDR can also quickly determine which seal(s) were opened. In this way the invention functions as a system of active seals. The invention is intended for applications that require long-term surveillance of a large number of closures. It provides immediate tamper detection, allows for periodic access to secured closures, and can be configured for many different distributions of closures. It can monitor closures in indoor and outdoor locations and it can monitor containers or groups of containers located many kilometers apart.

  1. Methods and predictors of tampering with a tamper-resistant controlled-release oxycodone formulation.

    PubMed

    Peacock, Amy; Degenhardt, Louisa; Hordern, Antonia; Larance, Briony; Cama, Elena; White, Nancy; Kihas, Ivana; Bruno, Raimondo

    2015-12-01

    In April 2014, a tamper-resistant controlled-release oxycodone formulation was introduced into the Australian market. This study aimed to identify the level and methods of tampering with reformulated oxycodone, demographic and clinical characteristics of those who reported tampering with reformulated oxycodone, and perceived attractiveness of original and reformulated oxycodone for misuse (via tampering). A prospective cohort of 522 people who regularly tampered with pharmaceutical opioids and had tampered with the original oxycodone product in their lifetime completed two interviews before (January-March 2014: Wave 1) and after (May-August 2014: Wave 2) introduction of reformulated oxycodone. Four-fifths (81%) had tampered with the original oxycodone formulation in the month prior to Wave 1; use and attempted tampering with reformulated oxycodone amongst the sample was comparatively low at Wave 2 (29% and 19%, respectively). Reformulated oxycodone was primarily swallowed (15%), with low levels of recent successful injection (6%), chewing (2%), drinking/dissolving (1%), and smoking (<1%). Participants who tampered with original and reformulated oxycodone were socio-demographically and clinically similar to those who had only tampered with the original formulation, except the former were more likely to report prescribed oxycodone use and stealing pharmaceutical opioid, and less likely to report moderate/severe anxiety. There was significant diversity in the methods for tampering, with attempts predominantly prompted by self-experimentation (rather than informed by word-of-mouth or the internet). Participants rated reformulated oxycodone as more difficult to prepare and inject and less pleasant to use compared to the original formulation. Current findings suggest that the introduction of the tamper-resistant product has been successful at reducing, although not necessarily eliminating, tampering with the controlled-release oxycodone formulation, with lower

  2. Detection of Tampering Inconsistencies on Mobile Photos

    NASA Astrophysics Data System (ADS)

    Cao, Hong; Kot, Alex C.

    Fast proliferation of mobile cameras and the deteriorating trust on digital images have created needs in determining the integrity of photos captured by mobile devices. As tampering often creates some inconsistencies, we propose in this paper a novel framework to statistically detect the image tampering inconsistency using accurately detected demosaicing weights features. By first cropping four non-overlapping blocks, each from one of the four quadrants in the mobile photo, we extract a set of demosaicing weights features from each block based on a partial derivative correlation model. Through regularizing the eigenspectrum of the within-photo covariance matrix and performing eigenfeature transformation, we further derive a compact set of eigen demosaicing weights features, which are sensitive to image signal mixing from different photo sources. A metric is then proposed to quantify the inconsistency based on the eigen weights features among the blocks cropped from different regions of the mobile photo. Through comparison, we show our eigen weights features perform better than the eigen features extracted from several other conventional sets of statistical forensics features in detecting the presence of tampering. Experimentally, our method shows a good confidence in tampering detection especially when one of the four cropped blocks is from a different camera model or brand with different demosaicing process.

  3. A graphite oxide (GO)-based remote readable tamper evident seal

    DOE PAGES

    Cattaneo, Alessandro; Bossert, Jason Andrew; Guzman, Christian; ...

    2016-09-08

    Here, this paper presents a prototype of a remotely readable graphite oxide (GO) paper-based tamper evident seal. The proposed device combines the tunable electrical properties offered by reduced graphite oxide (RGO) with a compressive sampling scheme. The benefit of using RGO as a tamper evident seal material is the sensitivity of its electrical properties to the common mechanisms adopted to defeat tamper-evident seals. RGO’s electrical properties vary upon local stress or cracks induced by mechanical action (e.g., produced by shimming or lifting attacks). Further, modification of the seal’s electrical properties can result from the incidence of other defeat mechanisms, suchmore » as temperature changes, solvent treatment and steam application. The electrical tunability of RGO enables the engraving of a circuit on the area of the tamper evident seal intended to be exposed to malicious attacks. The operation of the tamper evident seal, as well as its remote communication functionality, is supervised by a microcontroller unit (MCU). The MCU uses the RGO-engraved circuitry to physically implement a compressive sampling acquisition procedure. The compressive sampling scheme provides the seal with self-authentication and self-state-of-health awareness capabilities. Finally, the prototype shows potential for use in low-power, embedded, remote-operation nonproliferation security related applications.« less

  4. DEVELOPMENT OF A TAMPER RESISTANT/INDICATING AEROSOL COLLECTION SYSTEM FOR ENVIRONMENTAL SAMPLING AT BULK HANDLING FACILITIES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sexton, L.

    2012-06-06

    Environmental sampling has become a key component of International Atomic Energy Agency (IAEA) safeguards approaches since its approval for use in 1996. Environmental sampling supports the IAEA's mission of drawing conclusions concerning the absence of undeclared nuclear material or nuclear activities in a Nation State. Swipe sampling is the most commonly used method for the collection of environmental samples from bulk handling facilities. However, augmenting swipe samples with an air monitoring system, which could continuously draw samples from the environment of bulk handling facilities, could improve the possibility of the detection of undeclared activities. Continuous sampling offers the opportunity tomore » collect airborne materials before they settle onto surfaces which can be decontaminated, taken into existing duct work, filtered by plant ventilation, or escape via alternate pathways (i.e. drains, doors). Researchers at the Savannah River National Laboratory and Oak Ridge National Laboratory have been working to further develop an aerosol collection technology that could be installed at IAEA safeguarded bulk handling facilities. The addition of this technology may reduce the number of IAEA inspector visits required to effectively collect samples. The principal sample collection device is a patented Aerosol Contaminant Extractor (ACE) which utilizes electrostatic precipitation principles to deposit particulates onto selected substrates. Recent work has focused on comparing traditional swipe sampling to samples collected via an ACE system, and incorporating tamper resistant and tamper indicating (TRI) technologies into the ACE system. Development of a TRI-ACE system would allow collection of samples at uranium/plutonium bulk handling facilities in a manner that ensures sample integrity and could be an important addition to the international nuclear safeguards inspector's toolkit. This work was supported by the Next Generation Safeguards Initiative (NGSI

  5. Reversible Data Hiding in FTIR Microspectroscopy Images with Tamper Indication and Payload Error Correction

    PubMed Central

    Seppänen, Tapio

    2017-01-01

    Fourier transform infrared (FTIR) microspectroscopy images contain information from the whole infrared spectrum used for microspectroscopic analyses. In combination with the FTIR image, visible light images are used to depict the area from which the FTIR spectral image was sampled. These two images are traditionally acquired as separate files. This paper proposes a histogram shifting-based data hiding technique to embed visible light images in FTIR spectral images producing single entities. The primary objective is to improve data management efficiency. Secondary objectives are confidentiality, availability, and reliability. Since the integrity of biomedical data is vital, the proposed method applies reversible data hiding. After extraction of the embedded data, the FTIR image is reversed to its original state. Furthermore, the proposed method applies authentication tags generated with keyed Hash-Based Message Authentication Codes (HMAC) to detect tampered or corrupted areas of FTIR images. The experimental results show that the FTIR spectral images carrying the payload maintain good perceptual fidelity and the payload can be reliably recovered even after bit flipping or cropping attacks. It has been also shown that extraction successfully removes all modifications caused by the payload. Finally, authentication tags successfully indicated tampered FTIR image areas. PMID:29259987

  6. Fiber Optic Tamper Indicating Enclosure (TIE); A Case Study in Authentication

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anheier, Norman C.; Benz, Jacob M.; Tanner, Jennifer E.

    2015-07-15

    A robust fiber optic-based tamper-indicating enclosure (TIE) has been developed by PNNL through funding by the National Nuclear Security Administration Office of Nuclear Verification over the past few years. The objective of this work is to allow monitors to have confidence in both the authenticity and integrity of the TIE and the monitoring equipment inside, throughout the time it may be located at a host facility. Incorporating authentication features into the design were the focus of fiscal year 2014 development efforts. Throughout the development process, modifications have been made to the physical TIE design based on lessons learned via exercisesmore » and expert elicitation. The end result is a robust and passive TIE which can be utilized to protect monitoring party equipment left in a host facility.« less

  7. 43 CFR 423.25 - Vandalism, tampering, and theft.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Vandalism, tampering, and theft. 423.25 Section 423.25 Public Lands: Interior Regulations Relating to Public Lands BUREAU OF RECLAMATION... of Conduct § 423.25 Vandalism, tampering, and theft. (a) You must not tamper or attempt to tamper...

  8. Uniquely identifiable tamper-evident device using coupling between subwavelength gratings

    NASA Astrophysics Data System (ADS)

    Fievre, Ange Marie Patricia

    Reliability and sensitive information protection are critical aspects of integrated circuits. A novel technique using near-field evanescent wave coupling from two subwavelength gratings (SWGs), with the input laser source delivered through an optical fiber is presented for tamper evidence of electronic components. The first grating of the pair of coupled subwavelength gratings (CSWGs) was milled directly on the output facet of the silica fiber using focused ion beam (FIB) etching. The second grating was patterned using e-beam lithography and etched into a glass substrate using reactive ion etching (RIE). The slightest intrusion attempt would separate the CSWGs and eliminate near-field coupling between the gratings. Tampering, therefore, would become evident. Computer simulations guided the design for optimal operation of the security solution. The physical dimensions of the SWGs, i.e. period and thickness, were optimized, for a 650 nm illuminating wavelength. The optimal dimensions resulted in a 560 nm grating period for the first grating etched in the silica optical fiber and 420 nm for the second grating etched in borosilicate glass. The incident light beam had a half-width at half-maximum (HWHM) of at least 7 microm to allow discernible higher transmission orders, and a HWHM of 28 microm for minimum noise. The minimum number of individual grating lines present on the optical fiber facet was identified as 15 lines. Grating rotation due to the cylindrical geometry of the fiber resulted in a rotation of the far-field pattern, corresponding to the rotation angle of moire fringes. With the goal of later adding authentication to tamper evidence, the concept of CSWGs signature was also modeled by introducing random and planned variations in the glass grating. The fiber was placed on a stage supported by a nanomanipulator, which permitted three-dimensional displacement while maintaining the fiber tip normal to the surface of the glass substrate. A 650 nm diode laser was

  9. Time-Domain Reflectometry for Tamper Indication in Unattended Monitoring Systems for Safeguards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tedeschi, Jonathan R.; Smith, Leon E.; Moore, David E.

    2014-12-01

    The International Atomic Energy Agency (IAEA) continues to expand its use of unattended, remotely monitored measurement systems. An increasing number of systems and an expanding family of instruments create challenges in terms of deployment efficiency and the implementation of data authentication measures. Pacific Northwest National Laboratory (PNNL) leads a collaboration that is exploring various tamper-indicating (TI) measures that could help to address some of the long-standing detector and data-transmission authentication challenges with IAEA’s unattended systems. PNNL is investigating the viability of active time-domain reflectometry (TDR) along two parallel but interconnected paths: (1) swept-frequency TDR as the highly flexible, laboratory goldmore » standard to which field-deployable options can be compared, and (2) a low-cost commercially available spread-spectrum TDR technology as one option for field implementation. This report describes PNNL’s progress and preliminary findings from the first year of the study, and describes the path forward.« less

  10. 40 CFR 205.58-2 - Tampering.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Tampering. 205.58-2 Section 205.58-2 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Medium and Heavy Trucks § 205.58-2 Tampering. (a) For each configuration...

  11. Integrated optical tamper sensor with planar waveguide

    DOEpatents

    Carson, Richard F.; Casalnuovo, Stephen A.

    1993-01-01

    A monolithic optical tamper sensor, comprising an optical emitter and detector, connected by an optical waveguide and placed into the critical entry plane of an enclosed sensitive region, the tamper sensor having a myriad of scraps of a material optically absorbent at the wavelength of interest, such that when the absorbent material is in place on the waveguide, an unique optical signature can be recorded, but when entry is attempted into the enclosed sensitive region, the scraps of absorbent material will be displaced and the optical/electrical signature of the tamper sensor will change and that change can be recorded.

  12. Integrated optical tamper sensor with planar waveguide

    DOEpatents

    Carson, R.F.; Casalnuovo, S.A.

    1993-01-05

    A monolithic optical tamper sensor, comprising an optical emitter and detector, connected by an optical waveguide and placed into the critical entry plane of an enclosed sensitive region, the tamper sensor having a myriad of scraps of a material optically absorbent at the wavelength of interest, such that when the absorbent material is in place on the waveguide, an unique optical signature can be recorded, but when entry is attempted into the enclosed sensitive region, the scraps of absorbent material will be displaced and the optical/electrical signature of the tamper sensor will change and that change can be recorded.

  13. Non-contact tamper sensing by electronic means

    DOEpatents

    Gritton, Dale G.

    1993-01-01

    A tamper-sensing system for an electronic tag 10 which is to be fixed to a surface 11 of an article 12, the tamper-sensing system comprising a capacitor having two non-contacting, capacitively-coupled elements 16, 19. Fixing of the body to the article will establish a precise location of the capacitor elements 16 and 19 relative to each other. When interrogated, the tag will generate a tamper-sensing signal having a value which is a function of the amount of capacity of the capacitor elements. The precise relative location of the capacitor elements cannot be duplicated if the tag is removed and affixed to a surrogate article having a fiducial capacitor element 19 fixed thereto. A very small displacement, in the order of 2-10 microns, of the capacitor elements relative to each other if the tag body is removed and fixed to a surrogate article will result in the tamper-sensing signal having a different, and detectable, value when the tag is interrogated.

  14. Ranking of sabotage/tampering avoidance technology alternatives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andrews, W.B.; Tabatabai, A.S.; Powers, T.B.

    1986-01-01

    Pacific Northwest Laboratory conducted a study to evaluate alternatives to the design and operation of nuclear power plants, emphasizing a reduction of their vulnerability to sabotage. Estimates of core melt accident frequency during normal operations and from sabotage/tampering events were used to rank the alternatives. Core melt frequency for normal operations was estimated using sensitivity analysis of results of probabilistic risk assessments. Core melt frequency for sabotage/tampering was estimated by developing a model based on probabilistic risk analyses, historic data, engineering judgment, and safeguards analyses of plant locations where core melt events could be initiated. Results indicate the most effectivemore » alternatives focus on large areas of the plant, increase safety system redundancy, and reduce reliance on single locations for mitigation of transients. Less effective options focus on specific areas of the plant, reduce reliance on some plant areas for safe shutdown, and focus on less vulnerable targets.« less

  15. Apparatus and method for detecting tampering in flexible structures

    DOEpatents

    Maxey, Lonnie C [Knoxville, TN; Haynes, Howard D [Knoxville, TN

    2011-02-01

    A system for monitoring or detecting tampering in a flexible structure includes taking electrical measurements on a sensing cable coupled to the structure, performing spectral analysis on the measured data, and comparing the spectral characteristics of the event to those of known benign and/or known suspicious events. A threshold or trigger value may used to identify an event of interest and initiate data collection. Alternatively, the system may be triggered at preset intervals, triggered manually, or triggered by a signal from another sensing device such as a motion detector. The system may be used to monitor electrical cables and conduits, hoses and flexible ducts, fences and other perimeter control devices, structural cables, flexible fabrics, and other flexible structures.

  16. 36 CFR 2.31 - Trespassing, tampering and vandalism.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 36 Parks, Forests, and Public Property 1 2014-07-01 2014-07-01 false Trespassing, tampering and... INTERIOR RESOURCE PROTECTION, PUBLIC USE AND RECREATION § 2.31 Trespassing, tampering and vandalism. (a) The following are prohibited: (1) Trespassing. Trespassing, entering or remaining in or upon property...

  17. 36 CFR 2.31 - Trespassing, tampering and vandalism.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 36 Parks, Forests, and Public Property 1 2013-07-01 2013-07-01 false Trespassing, tampering and... INTERIOR RESOURCE PROTECTION, PUBLIC USE AND RECREATION § 2.31 Trespassing, tampering and vandalism. (a) The following are prohibited: (1) Trespassing. Trespassing, entering or remaining in or upon property...

  18. 36 CFR 2.31 - Trespassing, tampering and vandalism.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 1 2011-07-01 2011-07-01 false Trespassing, tampering and... INTERIOR RESOURCE PROTECTION, PUBLIC USE AND RECREATION § 2.31 Trespassing, tampering and vandalism. (a) The following are prohibited: (1) Trespassing. Trespassing, entering or remaining in or upon property...

  19. 36 CFR 2.31 - Trespassing, tampering and vandalism.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 36 Parks, Forests, and Public Property 1 2012-07-01 2012-07-01 false Trespassing, tampering and... INTERIOR RESOURCE PROTECTION, PUBLIC USE AND RECREATION § 2.31 Trespassing, tampering and vandalism. (a) The following are prohibited: (1) Trespassing. Trespassing, entering or remaining in or upon property...

  20. 36 CFR 2.31 - Trespassing, tampering and vandalism.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Trespassing, tampering and... INTERIOR RESOURCE PROTECTION, PUBLIC USE AND RECREATION § 2.31 Trespassing, tampering and vandalism. (a) The following are prohibited: (1) Trespassing. Trespassing, entering or remaining in or upon property...

  1. Tampered Region Localization of Digital Color Images Based on JPEG Compression Noise

    NASA Astrophysics Data System (ADS)

    Wang, Wei; Dong, Jing; Tan, Tieniu

    With the availability of various digital image edit tools, seeing is no longer believing. In this paper, we focus on tampered region localization for image forensics. We propose an algorithm which can locate tampered region(s) in a lossless compressed tampered image when its unchanged region is output of JPEG decompressor. We find the tampered region and the unchanged region have different responses for JPEG compression. The tampered region has stronger high frequency quantization noise than the unchanged region. We employ PCA to separate different spatial frequencies quantization noises, i.e. low, medium and high frequency quantization noise, and extract high frequency quantization noise for tampered region localization. Post-processing is involved to get final localization result. The experimental results prove the effectiveness of our proposed method.

  2. 36 CFR 1002.31 - Trespassing, tampering and vandalism.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Trespassing, tampering and..., PUBLIC USE AND RECREATION § 1002.31 Trespassing, tampering and vandalism. (a) The following are prohibited: (1) Trespassing. Trespassing, entering or remaining in or upon property or real property not open...

  3. 36 CFR 1002.31 - Trespassing, tampering and vandalism.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 36 Parks, Forests, and Public Property 3 2012-07-01 2012-07-01 false Trespassing, tampering and..., PUBLIC USE AND RECREATION § 1002.31 Trespassing, tampering and vandalism. (a) The following are prohibited: (1) Trespassing. Trespassing, entering or remaining in or upon property or real property not open...

  4. 36 CFR 1002.31 - Trespassing, tampering and vandalism.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 36 Parks, Forests, and Public Property 3 2014-07-01 2014-07-01 false Trespassing, tampering and..., PUBLIC USE AND RECREATION § 1002.31 Trespassing, tampering and vandalism. (a) The following are prohibited: (1) Trespassing. Trespassing, entering or remaining in or upon property or real property not open...

  5. 36 CFR 1002.31 - Trespassing, tampering and vandalism.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Trespassing, tampering and..., PUBLIC USE AND RECREATION § 1002.31 Trespassing, tampering and vandalism. (a) The following are prohibited: (1) Trespassing. Trespassing, entering or remaining in or upon property or real property not open...

  6. Development of a video tampering dataset for forensic investigation.

    PubMed

    Ismael Al-Sanjary, Omar; Ahmed, Ahmed Abdullah; Sulong, Ghazali

    2016-09-01

    Forgery is an act of modifying a document, product, image or video, among other media. Video tampering detection research requires an inclusive database of video modification. This paper aims to discuss a comprehensive proposal to create a dataset composed of modified videos for forensic investigation, in order to standardize existing techniques for detecting video tampering. The primary purpose of developing and designing this new video library is for usage in video forensics, which can be consciously associated with reliable verification using dynamic and static camera recognition. To the best of the author's knowledge, there exists no similar library among the research community. Videos were sourced from YouTube and by exploring social networking sites extensively by observing posted videos and rating their feedback. The video tampering dataset (VTD) comprises a total of 33 videos, divided among three categories in video tampering: (1) copy-move, (2) splicing, and (3) swapping-frames. Compared to existing datasets, this is a higher number of tampered videos, and with longer durations. The duration of every video is 16s, with a 1280×720 resolution, and a frame rate of 30 frames per second. Moreover, all videos possess the same formatting quality (720p(HD).avi). Both temporal and spatial video features were considered carefully during selection of the videos, and there exists complete information related to the doctored regions in every modified video in the VTD dataset. This database has been made publically available for research on splicing, Swapping frames, and copy-move tampering, and, as such, various video tampering detection issues with ground truth. The database has been utilised by many international researchers and groups of researchers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. A Secure and Robust Approach to Software Tamper Resistance

    NASA Astrophysics Data System (ADS)

    Ghosh, Sudeep; Hiser, Jason D.; Davidson, Jack W.

    Software tamper-resistance mechanisms have increasingly assumed significance as a technique to prevent unintended uses of software. Closely related to anti-tampering techniques are obfuscation techniques, which make code difficult to understand or analyze and therefore, challenging to modify meaningfully. This paper describes a secure and robust approach to software tamper resistance and obfuscation using process-level virtualization. The proposed techniques involve novel uses of software check summing guards and encryption to protect an application. In particular, a virtual machine (VM) is assembled with the application at software build time such that the application cannot run without the VM. The VM provides just-in-time decryption of the program and dynamism for the application's code. The application's code is used to protect the VM to ensure a level of circular protection. Finally, to prevent the attacker from obtaining an analyzable snapshot of the code, the VM periodically discards all decrypted code. We describe a prototype implementation of these techniques and evaluate the run-time performance of applications using our system. We also discuss how our system provides stronger protection against tampering attacks than previously described tamper-resistance approaches.

  8. Tamper indicating seal

    DOEpatents

    Romero, Juan A [Albuquerque, NM; Walker, Charles A [Albuquerque, NM; Blair, Dianna S [Albuquerque, NM; Bodmer, Connie C [Albuquerque, NM

    2012-05-29

    Seals have a flexible wire that can be looped through a hasp-like device. The seals include a body having a recess, a plug insertable into the recess and a snap ring for fastening the plug to the body. The plug and/or body can have access holes for inserting the wire into the recess. "Teeth" on the outer diameter and through-holes through the thickness of the snap ring allow for passing the ends of the flexible wire from the recess through the snap ring. The ends of the wire can be folded back over the snap ring and into engagement with the teeth. Assembly of the seal causes the ends of the wire to be securely fastened between the teeth of the snap ring and the sidewall of the recess. Seals can include a plug and/or body made of a frangible material such as glass, ceramic, glass-ceramic or brittle polymer.

  9. Blind technique using blocking artifacts and entropy of histograms for image tampering detection

    NASA Astrophysics Data System (ADS)

    Manu, V. T.; Mehtre, B. M.

    2017-06-01

    The tremendous technological advancements in recent times has enabled people to create, edit and circulate images easily than ever before. As a result of this, ensuring the integrity and authenticity of the images has become challenging. Malicious editing of images to deceive the viewer is referred to as image tampering. A widely used image tampering technique is image splicing or compositing, in which regions from different images are copied and pasted. In this paper, we propose a tamper detection method utilizing the blocking and blur artifacts which are the footprints of splicing. The classification of images as tampered or not, is done based on the standard deviations of the entropy histograms and block discrete cosine transformations. We can detect the exact boundaries of the tampered area in the image, if the image is classified as tampered. Experimental results on publicly available image tampering datasets show that the proposed method outperforms the existing methods in terms of accuracy.

  10. Ephemeral profiles of prescription drug and formulation tampering: evolving pseudoscience on the Internet.

    PubMed

    Cone, Edward J

    2006-06-01

    The magnitude of non-therapeutic use, or misuse of prescription pharmaceuticals now rivals that of illicit drug abuse. Drug and formulation tampering enables misusers to administer higher doses by intended and non-intended routes. Perceived motives appear to be a combination of interests in achieving a faster onset and enhancing psychoactive effects. Narcotic analgesics, stimulants, and depressants are widely sought, examined, and tampered with for recreational use. This review examines tampering methods reported on the Internet for selected pharmaceutical products. The Internet provides broad and varied guidance on tampering methods that are specific to drug classes and unique formulations. Instructions are available on crushing, separating, purifying and chemically altering specific formulations to allow changes in dosage, route of administration, and time course of effects. Many pharmaceutical formulations contain features that serve as "barriers" to tampering. The nature and effectiveness of formulation barriers vary widely with many being overcome by adventurous misusers. Examples of successes and failures in tampering attempts are frequently described on Internet sites that support recreational drug use. Successful tampering methods that have widespread appeal evolve into recipes and become archived on multiple websites. Examples of tampering methods include: (1) how to separate narcotic drugs (codeine, hydrocodone, oxycodone) from excipients and non-desirable actives (aspirin, acetaminophen, ibuprofen); (2) overcoming time-release formulations (beads, layers, matrices); (3) removal of active drug from high-dose formulations (patches, pills); (4) alteration of dosage forms for alternate routes of administration. The development of successful formulations that inhibit or prevent drug/formulation tampering with drugs of abuse should take into consideration the scope and practice of tampering methods available to recreational drug users on the Internet.

  11. 36 CFR § 1002.31 - Trespassing, tampering and vandalism.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 36 Parks, Forests, and Public Property 3 2013-07-01 2012-07-01 true Trespassing, tampering and... PROTECTION, PUBLIC USE AND RECREATION § 1002.31 Trespassing, tampering and vandalism. (a) The following are prohibited: (1) Trespassing. Trespassing, entering or remaining in or upon property or real property not open...

  12. 50 CFR 27.65 - Tampering with vehicles and equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 8 2011-10-01 2011-10-01 false Tampering with vehicles and equipment. 27.65 Section 27.65 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM PROHIBITED ACTS Disturbing Violations: Against Nonwildlife Property § 27.65 Tampering with...

  13. 50 CFR 27.65 - Tampering with vehicles and equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 9 2012-10-01 2012-10-01 false Tampering with vehicles and equipment. 27.65 Section 27.65 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM PROHIBITED ACTS Disturbing Violations: Against Nonwildlife Property § 27.65 Tampering with...

  14. Evidence of tampering in watermark identification

    NASA Astrophysics Data System (ADS)

    McLauchlan, Lifford; Mehrübeoglu, Mehrübe

    2009-08-01

    In this work, watermarks are embedded in digital images in the discrete wavelet transform (DWT) domain. Principal component analysis (PCA) is performed on the DWT coefficients. Next higher order statistics based on the principal components and the eigenvalues are determined for different sets of images. Feature sets are analyzed for different types of attacks in m dimensional space. The results demonstrate the separability of the features for the tampered digital copies. Different feature sets are studied to determine more effective tamper evident feature sets. The digital forensics, the probable manipulation(s) or modification(s) performed on the digital information can be identified using the described technique.

  15. A comparison among tapentadol tamper-resistant formulations (TRF) and OxyContin® (non-TRF) in prescription opioid abusers

    PubMed Central

    Vosburg, Suzanne K.; Jones, Jermaine D.; Manubay, Jeanne M.; Ashworth, Judy B.; Shapiro, Douglas Y.; Comer, Sandra D.

    2013-01-01

    Aims To examine whether tamper-resistant formulations (TRFs) of tapentadol hydrochloride ER 50 mg (TAP50) and tapentadol hydrochloride 250 mg (TAP250) could be converted into forms amenable to intranasal (Study 1) or intravenous abuse (Study 2). Design Randomized, repeated-measures study designs were employed. A non-TRF of OxyContin® 40 mg (OXY40) served as a positive control. No drug was taken in either study. Setting The studies took place in an outpatient setting in New York, NY. Participants 25 experienced, healthy extended-release oxycodone abusers participated in each study. Measurements The primary outcome for Study 1 was percentage of participants who indicated they would snort the tampered tablets, while the primary outcome for Study 2 was percent yield of active drug in solution. Other descriptive variables such as time spent manipulating the tablets were also examined to better characterize tampering behaviors. Findings Tampered TRF tablets were less desirable than the tampered OXY40 tablets. Few individuals were willing to snort the TRF particles (TAP50: 24%, TAP250: 16%; OXY40: 100% p<.001). There was less drug extracted from the TAP50 tablet than from the OXY40 tablet (3.5% vs. 37.0%, p=.008), and no samples from the TAP250 tablets contained analyzable solutions of the drug. It took participants longer to tamper with the TAPs (Study 1: TAP50 vs. OXY40, p<.01; TAP250 vs. OXY40, p<.01; Study 2: TAP250 vs. OXY40, p<05). Conclusions Taptentadol TRF tablets were not well-liked by individuals who regularly tampered with extended-release oxycodone tablets. Employing tamper resistant technology may be a promising approach towards reducing the abuse potential of tapentadol ER. PMID:23316699

  16. 25 CFR 11.440 - Tampering with or fabricating physical evidence.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 1 2014-04-01 2014-04-01 false Tampering with or fabricating physical evidence. 11.440 Section 11.440 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAW AND ORDER COURTS OF INDIAN OFFENSES AND LAW AND ORDER CODE Criminal Offenses § 11.440 Tampering with or fabricating physical evidence...

  17. 25 CFR 11.440 - Tampering with or fabricating physical evidence.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 1 2011-04-01 2011-04-01 false Tampering with or fabricating physical evidence. 11.440 Section 11.440 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAW AND ORDER COURTS OF INDIAN OFFENSES AND LAW AND ORDER CODE Criminal Offenses § 11.440 Tampering with or fabricating physical evidence...

  18. Secure RFID tag or sensor with self-destruction mechanism upon tampering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nekoogar, Faranak; Dowla, Farid; Twogood, Richard

    A circuit board anti-tamper mechanism comprises a circuit board having a frangible portion, a trigger having a trigger spring, a trigger arming mechanism actuated by the trigger wherein the trigger arming mechanism is initially non-actuated, a force producing mechanism, a latch providing mechanical communication between the trigger arming mechanism and the force producing mechanism, wherein the latch initially retains the force producing mechanism in a refracted position. Arming pressure applied to the trigger sufficient to overcome the trigger spring force will actuate the trigger arming mechanism, causing the anti-tamper mechanism to be armed. Subsequent tampering with the anti-tamper mechanism resultsmore » in a decrease of pressure on the trigger below the trigger spring force, thereby causing the trigger arming mechanism to actuate the latch, thereby releasing the force producing mechanism to apply force to the frangible portion of the circuit board, thereby breaking the circuit board.« less

  19. Medical Image Tamper Detection Based on Passive Image Authentication.

    PubMed

    Ulutas, Guzin; Ustubioglu, Arda; Ustubioglu, Beste; V Nabiyev, Vasif; Ulutas, Mustafa

    2017-12-01

    Telemedicine has gained popularity in recent years. Medical images can be transferred over the Internet to enable the telediagnosis between medical staffs and to make the patient's history accessible to medical staff from anywhere. Therefore, integrity protection of the medical image is a serious concern due to the broadcast nature of the Internet. Some watermarking techniques are proposed to control the integrity of medical images. However, they require embedding of extra information (watermark) into image before transmission. It decreases visual quality of the medical image and can cause false diagnosis. The proposed method uses passive image authentication mechanism to detect the tampered regions on medical images. Structural texture information is obtained from the medical image by using local binary pattern rotation invariant (LBPROT) to make the keypoint extraction techniques more successful. Keypoints on the texture image are obtained with scale invariant feature transform (SIFT). Tampered regions are detected by the method by matching the keypoints. The method improves the keypoint-based passive image authentication mechanism (they do not detect tampering when the smooth region is used for covering an object) by using LBPROT before keypoint extraction because smooth regions also have texture information. Experimental results show that the method detects tampered regions on the medical images even if the forged image has undergone some attacks (Gaussian blurring/additive white Gaussian noise) or the forged regions are scaled/rotated before pasting.

  20. Tamper-Resistant Mobile Health Using Blockchain Technology

    PubMed Central

    2017-01-01

    Background Digital health technologies, including telemedicine, mobile health (mHealth), and remote monitoring, are playing a greater role in medical practice. Safe and accurate management of medical information leads to the advancement of digital health, which in turn results in a number of beneficial effects. Furthermore, mHealth can help lower costs by facilitating the delivery of care and connecting people to their health care providers. Mobile apps help empower patients and health care providers to proactively address medical conditions through near real-time monitoring and treatment, regardless of the location of the patient or the health care provider. Additionally, mHealth data are stored in servers, and consequently, data management that prevents all forms of manipulation is crucial for both medical practice and clinical trials. Objective The aim of this study was to develop and evaluate a tamper-resistant mHealth system using blockchain technology, which enables trusted and auditable computing using a decentralized network. Methods We developed an mHealth system for cognitive behavioral therapy for insomnia using a smartphone app. The volunteer data collected with the app were stored in JavaScript Object Notation format and sent to the blockchain network. Thereafter, we evaluated the tamper resistance of the data against the inconsistencies caused by artificial faults. Results Electronic medical records collected using smartphones were successfully sent to a private Hyperledger Fabric blockchain network. We verified the data update process under conditions where all the validating peers were running normally. The mHealth data were successfully updated under network faults. We further ensured that any electronic health record registered to the blockchain network was resistant to tampering and revision. The mHealth data update was compatible with tamper resistance in the blockchain network. Conclusions Blockchain serves as a tamperproof system for m

  1. Tamper-Resistant Mobile Health Using Blockchain Technology.

    PubMed

    Ichikawa, Daisuke; Kashiyama, Makiko; Ueno, Taro

    2017-07-26

    Digital health technologies, including telemedicine, mobile health (mHealth), and remote monitoring, are playing a greater role in medical practice. Safe and accurate management of medical information leads to the advancement of digital health, which in turn results in a number of beneficial effects. Furthermore, mHealth can help lower costs by facilitating the delivery of care and connecting people to their health care providers. Mobile apps help empower patients and health care providers to proactively address medical conditions through near real-time monitoring and treatment, regardless of the location of the patient or the health care provider. Additionally, mHealth data are stored in servers, and consequently, data management that prevents all forms of manipulation is crucial for both medical practice and clinical trials. The aim of this study was to develop and evaluate a tamper-resistant mHealth system using blockchain technology, which enables trusted and auditable computing using a decentralized network. We developed an mHealth system for cognitive behavioral therapy for insomnia using a smartphone app. The volunteer data collected with the app were stored in JavaScript Object Notation format and sent to the blockchain network. Thereafter, we evaluated the tamper resistance of the data against the inconsistencies caused by artificial faults. Electronic medical records collected using smartphones were successfully sent to a private Hyperledger Fabric blockchain network. We verified the data update process under conditions where all the validating peers were running normally. The mHealth data were successfully updated under network faults. We further ensured that any electronic health record registered to the blockchain network was resistant to tampering and revision. The mHealth data update was compatible with tamper resistance in the blockchain network. Blockchain serves as a tamperproof system for mHealth. Combining mHealth with blockchain technology may

  2. 40 CFR 205.173-2 - Tampering.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... removal or puncturing the muffler, baffles, header pipes, or any other component which conducts exhaust... EQUIPMENT NOISE EMISSION CONTROLS Motorcycle Exhaust Systems § 205.173-2 Tampering. The manufacturer must... exhaust system which causes the motorcycle to exceed the Federal noise standard. Use of the motorcycle...

  3. Evaluation of the resistance of a geopolymer-based drug delivery system to tampering.

    PubMed

    Cai, Bing; Engqvist, Håkan; Bredenberg, Susanne

    2014-04-25

    Tamper-resistance is an important property of controlled-release formulations of opioid drugs. Tamper-resistant formulations aim to increase the degree of effort required to override the controlled release of the drug molecules from extended-release formulations for the purpose of non-medical use. In this study, the resistance of a geopolymer-based formulation to tampering was evaluated by comparing it with a commercial controlled-release tablet using several methods commonly used by drug abusers. Because of its high compressive strength and resistance to heat, much more effort and time was required to extract the drug from the geopolymer-based formulation. Moreover, in the drug-release test, the geopolymer-based formulation maintained its controlled-release characteristics after milling, while the drug was released immediately from the milled commercial tablets, potentially resulting in dose dumping. Although the tampering methods used in this study does not cover all methods that abuser could access, the results obtained by the described methods showed that the geopolymer matrix increased the degree of effort required to override the controlled release of the drug, suggesting that the formulation has improved resistance to some common drug-abuse tampering methods. The geopolymer matrix has the potential to make the opioid product less accessible and attractive to non-medical users. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. 49 CFR Appendix C to Part 218 - Statement of Agency Enforcement Policy on Tampering

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Tampering C Appendix C to Part 218 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD OPERATING PRACTICES Pt. 218, App. C Appendix C to Part 218—Statement of Agency Enforcement Policy on Tampering The Rail Safety Improvement Act...

  5. 49 CFR Appendix C to Part 218 - Statement of Agency Enforcement Policy on Tampering

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Tampering C Appendix C to Part 218 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD OPERATING PRACTICES Pt. 218, App. C Appendix C to Part 218—Statement of Agency Enforcement Policy on Tampering The Rail Safety Improvement Act...

  6. 49 CFR Appendix C to Part 218 - Statement of Agency Enforcement Policy on Tampering

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Tampering C Appendix C to Part 218 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD OPERATING PRACTICES Pt. 218, App. C Appendix C to Part 218—Statement of Agency Enforcement Policy on Tampering The Rail Safety Improvement Act...

  7. Adolescent pedometer protocols: examining reactivity, tampering and participants' perceptions.

    PubMed

    Scott, Joseph John; Morgan, Philip James; Plotnikoff, Ronald Cyril; Trost, Stewart Graeme; Lubans, David Revalds

    2014-01-01

    The aim of this study was to investigate adolescents' potential reactivity and tampering while wearing pedometers by comparing different monitoring protocols to accelerometer output. The sample included adolescents (N = 123, age range = 14-15 years) from three secondary schools in New South Wales, Australia. Schools were randomised to one of the three pedometer monitoring protocols: (i) daily sealed (DS) pedometer group, (ii) unsealed (US) pedometer group or (iii) weekly sealed (WS) pedometer group. Participants wore pedometers (Yamax Digi-Walker CW700, Yamax Corporation, Kumamoto City, Japan) and accelerometers (Actigraph GT3X+, Pensacola, USA) simultaneously for seven days. Repeated measures analysis of variance was used to examine potential reactivity. Bivariate correlations between step counts and accelerometer output were calculated to explore potential tampering. The correlation between accelerometer output and pedometer steps/day was strongest among participants in the WS group (r = 0.82, P ≤ 0.001), compared to the US (r = 0.63, P ≤ 0.001) and DS (r = 0.16, P = 0.324) groups. The DS (P ≤ 0.001) and US (P = 0.003), but not the WS (P = 0.891), groups showed evidence of reactivity. The results suggest that reactivity and tampering does occur in adolescents and contrary to existing research, pedometer monitoring protocols may influence participant behaviour.

  8. Tamper to delay motion and decrease ionization of a sample during short pulse x-ray imaging

    DOEpatents

    London, Richard A [Orinda, CA; Szoke,; Abraham, Hau-Riege [Fremont, CA; Stefan P. , Chapman; Henry, N [Livermore, CA

    2007-06-26

    A system for x-ray imaging of a small sample comprising positioning a tamper so that it is operatively connected to the sample, directing short intense x-ray pulses onto the tamper and the sample, and detecting an image from the sample. The tamper delays the explosive motion of the sample during irradiation by the short intense x-ray pulses, thereby extending the time to obtain an x-ray image of the original structure of the sample.

  9. 21 CFR 211.132 - Tamper-evident packaging requirements for over-the-counter (OTC) human drug products.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... dermatological, dentifrice, insulin, or lozenge product) for retail sale that is not packaged in a tamper..., dentifrice, insulin, or lozenge product) for retail sale shall package the product in a tamper-evident...

  10. 21 CFR 211.132 - Tamper-evident packaging requirements for over-the-counter (OTC) human drug products.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... dermatological, dentifrice, insulin, or lozenge product) for retail sale that is not packaged in a tamper..., dentifrice, insulin, or lozenge product) for retail sale shall package the product in a tamper-evident...

  11. 21 CFR 211.132 - Tamper-evident packaging requirements for over-the-counter (OTC) human drug products.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... dermatological, dentifrice, insulin, or lozenge product) for retail sale that is not packaged in a tamper..., dentifrice, insulin, or lozenge product) for retail sale shall package the product in a tamper-evident...

  12. 21 CFR 211.132 - Tamper-evident packaging requirements for over-the-counter (OTC) human drug products.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... dermatological, dentifrice, insulin, or lozenge product) for retail sale that is not packaged in a tamper..., dentifrice, insulin, or lozenge product) for retail sale shall package the product in a tamper-evident...

  13. 21 CFR 211.132 - Tamper-evident packaging requirements for over-the-counter (OTC) human drug products.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... dermatological, dentifrice, insulin, or lozenge product) for retail sale that is not packaged in a tamper..., dentifrice, insulin, or lozenge product) for retail sale shall package the product in a tamper-evident...

  14. Detecting Test Tampering Using Item Response Theory

    ERIC Educational Resources Information Center

    Wollack, James A.; Cohen, Allan S.; Eckerly, Carol A.

    2015-01-01

    Test tampering, especially on tests for educational accountability, is an unfortunate reality, necessitating that the state (or its testing vendor) perform data forensic analyses, such as erasure analyses, to look for signs of possible malfeasance. Few statistical approaches exist for detecting fraudulent erasures, and those that do largely do not…

  15. Test-Tampering Found Rampant in Atlanta System

    ERIC Educational Resources Information Center

    Samuels, Christina A.

    2011-01-01

    The author reports on a state investigation into Atlanta's impressive gains on state tests which finds that test-tampering was rampant in the much-praised school system. The report unveiled by the Georgia governor's office states that Atlanta teachers and principals for years methodically altered answer sheets for students taking state tests,…

  16. 75 FR 79049 - Final Regulatory Guide: Issuance, Availability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-17

    ... (RG) 5.80, ``Pressure-Sensitive and Tamper-Indicating Device Seals for Material Control and Accounting... and licenses. Regulatory Guide 5.80, ``Pressure-Sensitive and Tamper-Indicating Device Seals for... and Use of Pressure-Sensitive Seals on Containers for Onsite Storage of Special Nuclear Material...

  17. 50 CFR 27.65 - Tampering with vehicles and equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... INTERIOR (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM PROHIBITED ACTS Disturbing Violations: Against... motor vehicle, boat, equipment or machinery or attempting to tamper with, enter, or start any motor vehicle, boat, equipment or machinery on any national wildlife refuge without proper authorization is...

  18. Effect of source tampering in the security of quantum cryptography

    NASA Astrophysics Data System (ADS)

    Sun, Shi-Hai; Xu, Feihu; Jiang, Mu-Sheng; Ma, Xiang-Chun; Lo, Hoi-Kwong; Liang, Lin-Mei

    2015-08-01

    The security of source has become an increasingly important issue in quantum cryptography. Based on the framework of measurement-device-independent quantum key distribution (MDI-QKD), the source becomes the only region exploitable by a potential eavesdropper (Eve). Phase randomization is a cornerstone assumption in most discrete-variable (DV) quantum communication protocols (e.g., QKD, quantum coin tossing, weak-coherent-state blind quantum computing, and so on), and the violation of such an assumption is thus fatal to the security of those protocols. In this paper, we show a simple quantum hacking strategy, with commercial and homemade pulsed lasers, by Eve that allows her to actively tamper with the source and violate such an assumption, without leaving a trace afterwards. Furthermore, our attack may also be valid for continuous-variable (CV) QKD, which is another main class of QKD protocol, since, excepting the phase random assumption, other parameters (e.g., intensity) could also be changed, which directly determine the security of CV-QKD.

  19. A Theorem and its Application to Finite Tampers

    DOE R&D Accomplishments Database

    Feynman, R. P.

    1946-08-15

    A theorem is derived which is useful in the analysis of neutron problems in which all neutrons have the same velocity. It is applied to determine extrapolated end-points, the asymptotic amplitude from a point source, and the neutron density at the surface of a medium. Formulas fro the effect of finite tampers are derived by its aid, and their accuracy discussed.

  20. An Efficient Semi-fragile Watermarking Scheme for Tamper Localization and Recovery

    NASA Astrophysics Data System (ADS)

    Hou, Xiang; Yang, Hui; Min, Lianquan

    2018-03-01

    To solve the problem that remote sensing images are vulnerable to be tampered, a semi-fragile watermarking scheme was proposed. Binary random matrix was used as the authentication watermark, which was embedded by quantizing the maximum absolute value of directional sub-bands coefficients. The average gray level of every non-overlapping 4×4 block was adopted as the recovery watermark, which was embedded in the least significant bit. Watermarking detection could be done directly without resorting to the original images. Experimental results showed our method was robust against rational distortions to a certain extent. At the same time, it was fragile to malicious manipulation, and realized accurate localization and approximate recovery of the tampered regions. Therefore, this scheme can protect the security of remote sensing image effectively.

  1. Hardware device binding and mutual authentication

    DOEpatents

    Hamlet, Jason R; Pierson, Lyndon G

    2014-03-04

    Detection and deterrence of device tampering and subversion by substitution may be achieved by including a cryptographic unit within a computing device for binding multiple hardware devices and mutually authenticating the devices. The cryptographic unit includes a physically unclonable function ("PUF") circuit disposed in or on the hardware device, which generates a binding PUF value. The cryptographic unit uses the binding PUF value during an enrollment phase and subsequent authentication phases. During a subsequent authentication phase, the cryptographic unit uses the binding PUF values of the multiple hardware devices to generate a challenge to send to the other device, and to verify a challenge received from the other device to mutually authenticate the hardware devices.

  2. Internet pseudoscience: Testing opioid containing formulations with tampering potential.

    PubMed

    Pascali, Jennifer P; Fais, Paolo; Vaiano, Fabio; Pigaiani, Nicola; D'Errico, Stefano; Furlanetto, Sandra; Palumbo, Diego; Bertol, Elisabetta

    2018-05-10

    Drug tampering practices, with the aim to increase availability of drug delivery and/or enhance drug effects, are accessible on Internet and are practiced by some portion of recreational drug users. Not rarely, recreational misuse may result in toxic and even fatal results. The aim of the present study was to assess the tampering risk of medicaments containing different formulations of an opioid in combination with paracetamol or dexketoprofen, following the procedures reported in dedicated forums on the web. Tablets and suppositories containing codeine, tramadol and oxycodone were extracted following the reported "Cold water extraction"; dextromethorphan was extracted from cough syrup following the procedure reported as "Acid/base extraction" and fentanyl was extracted from transdermal patches according the procedure reported in Internet. The tampered products and opportunely prepared calibrators in water were analysed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The separation of the analytes was carried on Agilent ZORBAX Eclipse Plus C18 (RRHT 2.1 mm × 50 mm, 1.8 μm) by the gradient elution of 0.01% formic acid in water and 0.01% formic acid in methanol. Acquisition was by MRM mode considering at least two transitions for compound. Declared recoveries for these home-made extractions claimed to exceed 99% for the opioid and to complete remove paracetamol, often associated to liver toxicity and thus to obtain a "safer" preparation. In this study, the authors demonstrated that rarely the recoveries for the opioid reached 90% and that up to 60% of the paracetamol amount remained in solution. Thus, high risks for health remained both for the potential lethality of the opioid content, but also for the sub-lethal chronic use of these mixtures, which contained still uncontrolled, ignored, but often important amounts of paracetamol. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. 21 CFR 864.5300 - Red cell indices device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Red cell indices device. 864.5300 Section 864.5300....5300 Red cell indices device. (a) Identification. A red cell indices device, usually part of a larger... corpuscular hemoglobin (MCH), and the mean corpuscular hemoglobin concentration (MCHC). The red cell indices...

  4. 21 CFR 864.5300 - Red cell indices device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Red cell indices device. 864.5300 Section 864.5300....5300 Red cell indices device. (a) Identification. A red cell indices device, usually part of a larger... corpuscular hemoglobin (MCH), and the mean corpuscular hemoglobin concentration (MCHC). The red cell indices...

  5. 21 CFR 864.5300 - Red cell indices device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Red cell indices device. 864.5300 Section 864.5300....5300 Red cell indices device. (a) Identification. A red cell indices device, usually part of a larger... corpuscular hemoglobin (MCH), and the mean corpuscular hemoglobin concentration (MCHC). The red cell indices...

  6. 21 CFR 864.5300 - Red cell indices device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Red cell indices device. 864.5300 Section 864.5300....5300 Red cell indices device. (a) Identification. A red cell indices device, usually part of a larger... corpuscular hemoglobin (MCH), and the mean corpuscular hemoglobin concentration (MCHC). The red cell indices...

  7. 21 CFR 864.5300 - Red cell indices device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Red cell indices device. 864.5300 Section 864.5300....5300 Red cell indices device. (a) Identification. A red cell indices device, usually part of a larger... corpuscular hemoglobin (MCH), and the mean corpuscular hemoglobin concentration (MCHC). The red cell indices...

  8. Efficiency of extraction and conversion of pseudoephedrine to methamphetamine from tamper-resistant and non-tamper-resistant formulations.

    PubMed

    Presley, Brandon; Bianchi, Bob; Coleman, John; Diamond, Fran; McNally, Gerry

    2018-07-15

    Clandestine chemists have demonstrated an ability to convert commercially available pseudoephedrine formulations to methamphetamine. Some of these formulations have properties that manufacturers claim limit or block the extraction of pseudoephedrine and its direct conversion to methamphetamine. In this study, 3 commercially available pseudoephedrine formulations were evaluated for ease of extraction and conversion to methamphetamine using a common chemistry technique called the one-pot method that is frequently employed by clandestine chemists. Two marketed pseudoephedrine formulations with claimed tamper-resistant properties - Zephrex-D ® and Nexafed ® - were compared to Sunmark ® , a comparator formulation of pseudoephedrine without tamper-resistant properties. Particle size reduction was conducted using 8 readily available tools; solubility was assessed using 2 common aqueous solutions and various reaction conditions (e.g., temperature, stirring); extractability was evaluated using 8 common organic solvents. The one-pot (single vessel) method commonly used in clandestine processes was employed; chemicals and equipment were purchased locally on the open market. Quantities and addition times of the chemicals used to carry out the procedure and the duration of the reaction were varied to determine the effect on methamphetamine yield. The procedure was appropriately scaled and conducted in a controlled environment to reduce risk and maximize yields. Pseudoephedrine and methamphetamine were quantified using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Standard quantitative procedures were used to determine the quantities of pseudoephedrine and methamphetamine recovered and produced, respectively. Particle size reduction resulted in some loss of material of each pseudoephedrine formulation; Zephrex-D tablets were broken down to a coarse material; Nexafed and Sunmark tablets were reduced to a fine powder. The solubility rates of intact and ground

  9. 21 CFR 700.25 - Tamper-resistant packaging requirements for cosmetic products.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... cosmetic products. 700.25 Section 700.25 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) COSMETICS GENERAL Requirements for Specific Cosmetic Products § 700.25 Tamper-resistant packaging requirements for cosmetic products. (a) General. Because most cosmetic liquid...

  10. 21 CFR 700.25 - Tamper-resistant packaging requirements for cosmetic products.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... cosmetic products. 700.25 Section 700.25 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) COSMETICS GENERAL Requirements for Specific Cosmetic Products § 700.25 Tamper-resistant packaging requirements for cosmetic products. (a) General. Because most cosmetic liquid...

  11. 21 CFR 700.25 - Tamper-resistant packaging requirements for cosmetic products.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... cosmetic products. 700.25 Section 700.25 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) COSMETICS GENERAL Requirements for Specific Cosmetic Products § 700.25 Tamper-resistant packaging requirements for cosmetic products. (a) General. Because most cosmetic liquid...

  12. 21 CFR 700.25 - Tamper-resistant packaging requirements for cosmetic products.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... cosmetic products. 700.25 Section 700.25 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) COSMETICS GENERAL Requirements for Specific Cosmetic Products § 700.25 Tamper-resistant packaging requirements for cosmetic products. (a) General. Because most cosmetic liquid...

  13. 21 CFR 872.1840 - Dental x-ray position indicating device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental x-ray position indicating device. 872.1840... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1840 Dental x-ray position indicating device. (a) Identification. A dental x-ray position indicating device is a device, such as a collimator...

  14. 21 CFR 872.1840 - Dental x-ray position indicating device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental x-ray position indicating device. 872.1840... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1840 Dental x-ray position indicating device. (a) Identification. A dental x-ray position indicating device is a device, such as a collimator...

  15. 21 CFR 872.1840 - Dental x-ray position indicating device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental x-ray position indicating device. 872.1840... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1840 Dental x-ray position indicating device. (a) Identification. A dental x-ray position indicating device is a device, such as a collimator...

  16. 21 CFR 872.1840 - Dental x-ray position indicating device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental x-ray position indicating device. 872.1840... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1840 Dental x-ray position indicating device. (a) Identification. A dental x-ray position indicating device is a device, such as a collimator...

  17. 21 CFR 872.1840 - Dental x-ray position indicating device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental x-ray position indicating device. 872.1840... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1840 Dental x-ray position indicating device. (a) Identification. A dental x-ray position indicating device is a device, such as a collimator...

  18. 21 CFR 700.25 - Tamper-resistant packaging requirements for cosmetic products.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Tamper-resistant packaging requirements for cosmetic products. 700.25 Section 700.25 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH... of cosmetic product packages. The Food and Drug Administration has the authority and responsibility...

  19. Wireless tamper detection sensor and sensing system

    NASA Technical Reports Server (NTRS)

    Woodard, Stanley E. (Inventor); Taylor, Bryant D. (Inventor)

    2011-01-01

    A wireless tamper detection sensor is defined by a perforated electrical conductor. The conductor is shaped to form a geometric pattern between first and second ends thereof such that the conductor defines an open-circuit that can store and transfer electrical and magnetic energy. The conductor resonates in the presence of a time-varying magnetic field to generate a harmonic response. The harmonic response changes when the conductor experiences a change in its geometric pattern due to severing of the conductor along at least a portion of the perforations. A magnetic field response recorder is used to wirelessly transmit the time-varying magnetic field and wirelessly detecting the conductor's harmonic response.

  20. Electronic security device

    DOEpatents

    Eschbach, E.A.; LeBlanc, E.J.; Griffin, J.W.

    1992-03-17

    The present invention relates to a security device having a control box containing an electronic system and a communications loop over which the system transmits a signal. The device is constructed so that the communications loop can extend from the control box across the boundary of a portal such as a door into a sealed enclosure into which access is restricted whereby the loop must be damaged or moved in order for an entry to be made into the enclosure. The device is adapted for detecting unauthorized entries into such enclosures such as rooms or containers and for recording the time at which such entries occur for later reference. Additionally, the device detects attempts to tamper or interfere with the operation of the device itself and records the time at which such events take place. In the preferred embodiment, the security device includes a microprocessor-based electronic system and a detection module capable of registering changes in the voltage and phase of the signal transmitted over the loop. 11 figs.

  1. Electronic security device

    DOEpatents

    Eschbach, Eugene A.; LeBlanc, Edward J.; Griffin, Jeffrey W.

    1992-01-01

    The present invention relates to a security device having a control box (12) containing an electronic system (50) and a communications loop (14) over which the system transmits a signal. The device is constructed so that the communications loop can extend from the control box across the boundary of a portal such as a door into a sealed enclosure into which access is restricted whereby the loop must be damaged or moved in order for an entry to be made into the enclosure. The device is adapted for detecting unauthorized entries into such enclosures such as rooms or containers and for recording the time at which such entries occur for later reference. Additionally, the device detects attempts to tamper or interfere with the operation of the device itself and records the time at which such events take place. In the preferred embodiment, the security device includes a microprocessor-based electronic system (50) and a detection module (72) capable of registering changes in the voltage and phase of the signal transmitted over the loop.

  2. 21 CFR 800.12 - Contact lens solutions and tablets; tamper-resistant packaging.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...-resistant retail packages, there is the opportunity for the malicious adulteration of these products with... confidence in the security of the packages of over-the-counter (OTC) health care products. The Food and Drug... used to make such a solution for retail sale that is not packaged in a tamper-resistant package and...

  3. 21 CFR 800.12 - Contact lens solutions and tablets; tamper-resistant packaging.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...-resistant retail packages, there is the opportunity for the malicious adulteration of these products with... confidence in the security of the packages of over-the-counter (OTC) health care products. The Food and Drug... used to make such a solution for retail sale that is not packaged in a tamper-resistant package and...

  4. 21 CFR 800.12 - Contact lens solutions and tablets; tamper-resistant packaging.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...-resistant retail packages, there is the opportunity for the malicious adulteration of these products with... confidence in the security of the packages of over-the-counter (OTC) health care products. The Food and Drug... used to make such a solution for retail sale that is not packaged in a tamper-resistant package and...

  5. 21 CFR 800.12 - Contact lens solutions and tablets; tamper-resistant packaging.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...-resistant retail packages, there is the opportunity for the malicious adulteration of these products with... confidence in the security of the packages of over-the-counter (OTC) health care products. The Food and Drug... used to make such a solution for retail sale that is not packaged in a tamper-resistant package and...

  6. 21 CFR 800.12 - Contact lens solutions and tablets; tamper-resistant packaging.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...-resistant retail packages, there is the opportunity for the malicious adulteration of these products with... confidence in the security of the packages of over-the-counter (OTC) health care products. The Food and Drug... used to make such a solution for retail sale that is not packaged in a tamper-resistant package and...

  7. Hardware device to physical structure binding and authentication

    DOEpatents

    Hamlet, Jason R.; Stein, David J.; Bauer, Todd M.

    2013-08-20

    Detection and deterrence of device tampering and subversion may be achieved by including a cryptographic fingerprint unit within a hardware device for authenticating a binding of the hardware device and a physical structure. The cryptographic fingerprint unit includes an internal physically unclonable function ("PUF") circuit disposed in or on the hardware device, which generate an internal PUF value. Binding logic is coupled to receive the internal PUF value, as well as an external PUF value associated with the physical structure, and generates a binding PUF value, which represents the binding of the hardware device and the physical structure. The cryptographic fingerprint unit also includes a cryptographic unit that uses the binding PUF value to allow a challenger to authenticate the binding.

  8. Security protection of DICOM medical images using dual-layer reversible watermarking with tamper detection capability.

    PubMed

    Tan, Chun Kiat; Ng, Jason Changwei; Xu, Xiaotian; Poh, Chueh Loo; Guan, Yong Liang; Sheah, Kenneth

    2011-06-01

    Teleradiology applications and universal availability of patient records using web-based technology are rapidly gaining importance. Consequently, digital medical image security has become an important issue when images and their pertinent patient information are transmitted across public networks, such as the Internet. Health mandates such as the Health Insurance Portability and Accountability Act require healthcare providers to adhere to security measures in order to protect sensitive patient information. This paper presents a fully reversible, dual-layer watermarking scheme with tamper detection capability for medical images. The scheme utilizes concepts of public-key cryptography and reversible data-hiding technique. The scheme was tested using medical images in DICOM format. The results show that the scheme is able to ensure image authenticity and integrity, and to locate tampered regions in the images.

  9. Conductive fabric seal

    DOEpatents

    Livesay, Ronald Jason; Mason, Brandon William; Kuhn, Michael Joseph; Rowe, Nathan Carl

    2017-04-04

    Disclosed are several examples of a system and method for detecting if an article is being tampered with. Included is a covering made of a substrate that is coated with a layer of an electrically conductive material that forms an electrically conductive surface having an electrical resistance. The covering is configured to at least partially encapsulate the article such that the article cannot be tampered with, without modifying the electrical resistance of the electrically conductive surface of the covering. A sensing device is affixed to the electrically conductive surface of the covering and the sensing device monitors the condition of the covering by producing a signal that is indicative of the electrical resistance of the electrically conductive surface of the covering. A measured electrical resistance that differs from a nominal electrical resistance is indicative of a covering that is being tampered with and an alert is communicated to an observer.

  10. Conductive fabric seal

    DOEpatents

    Livesay, Ronald Jason; Mason, Brandon William; Kuhn, Michael Joseph; Rowe, Nathan Carl

    2015-10-13

    Disclosed are several examples of a system and method for detecting if an article is being tampered with. Included is a covering made of a substrate that is coated with a layer of an electrically conductive material that forms an electrically conductive surface having an electrical resistance. The covering is configured to at least partially encapsulate the article such that the article cannot be tampered with, without modifying the electrical resistance of the electrically conductive surface of the covering. A sensing device is affixed to the electrically conductive surface of the covering and the sensing device monitors the condition of the covering by producing a signal that is indicative of the electrical resistance of the electrically conductive surface of the covering. A measured electrical resistance that differs from a nominal electrical resistance is indicative of a covering that is being tampered with and an alert is communicated to an observer.

  11. 33 CFR 164.40 - Devices to indicate speed and distance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Devices to indicate speed and... speed and distance. (a) Each vessel required to be fitted with an Automatic Radar Plotting Aid (ARPA) under § 164.38 of this part must be fitted with a device to indicate speed and distance of the vessel...

  12. 33 CFR 164.40 - Devices to indicate speed and distance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Devices to indicate speed and... speed and distance. (a) Each vessel required to be fitted with an Automatic Radar Plotting Aid (ARPA) under § 164.38 of this part must be fitted with a device to indicate speed and distance of the vessel...

  13. The Social Construction of the Urban Use of Information Technology: The Case of Tampere, Finland

    ERIC Educational Resources Information Center

    Inkinen, Tommi

    2006-01-01

    This paper explores the social use of information and communication technologies (ICTs) in the city of Tampere, Finland. It focuses on two essential elements: the city (as the location with national context) and citizens (as members of the "local" information society). The paper also examines the question of building social networks via…

  14. Simple Magnetic Device Indicates Thickness Of Alloy 903

    NASA Technical Reports Server (NTRS)

    Long, Pin Jeng; Rodriguez, Sergio; Bright, Mark L.

    1995-01-01

    Handheld device called "ferrite indicator" orginally designed for use in determining ferrite content of specimen of steel. Placed in contact with specimen and functions by indicating whether magnet attracted more strongly to specimen or to calibrated reference sample. Relative strength of attraction shows whether alloy overlay thinner than allowable.

  15. "Tampering to Death": A Fatal Codeine Intoxication Due to a Homemade Purification of a Medical Formulation.

    PubMed

    Fais, Paolo; Pigaiani, Nicola; Cecchetto, Giovanni; Montisci, Massimo; Gottardo, Rossella; Viel, Guido; Pascali, Jennifer Paola; Tagliaro, Franco

    2017-11-01

    Many homemade tamper processes of medical codeine formulations are available on selected "forums" on the Internet, where recreational codeine users claim to be able to purify codeine by removing additives, such as acetaminophen, to avoid or limit adverse effects. In this work, it is reported and discussed a fatal case of codeine intoxication. The findings of objects such as jars, filters, and tablets, and amounts of unknown liquid material at the death scene investigation suggested a fatal codeine intoxication after the tampering procedure called "cold water extraction." Toxicological results obtained from the analysis of both the nonbiological material and the body fluids of the decedent integrated with the information collected at the death scene investigation confirmed the above-mentioned hypothesis. This report underlines the importance of a tight interconnection between criminalistics and legal medicine to strengthen the identification of the cause of death and the reconstruction of the event. © 2017 American Academy of Forensic Sciences.

  16. 10 CFR 73.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... this part. Intrusion alarm means a tamper indicating electrical, electromechanical, electrooptical... manipulation resistant, electromechanical device which provides the same function as a built-in combination...

  17. 10 CFR 73.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... this part. Intrusion alarm means a tamper indicating electrical, electromechanical, electrooptical... manipulation resistant, electromechanical device which provides the same function as a built-in combination...

  18. Use of multiple colorimetric indicators for paper-based microfluidic devices.

    PubMed

    Dungchai, Wijitar; Chailapakul, Orawon; Henry, Charles S

    2010-08-03

    We report here the use of multiple indicators for a single analyte for paper-based microfluidic devices (microPAD) in an effort to improve the ability to visually discriminate between analyte concentrations. In existing microPADs, a single dye system is used for the measurement of a single analyte. In our approach, devices are designed to simultaneously quantify analytes using multiple indicators for each analyte improving the accuracy of the assay. The use of multiple indicators for a single analyte allows for different indicator colors to be generated at different analyte concentration ranges as well as increasing the ability to better visually discriminate colors. The principle of our devices is based on the oxidation of indicators by hydrogen peroxide produced by oxidase enzymes specific for each analyte. Each indicator reacts at different peroxide concentrations and therefore analyte concentrations, giving an extended range of operation. To demonstrate the utility of our approach, the mixture of 4-aminoantipyrine and 3,5-dichloro-2-hydroxy-benzenesulfonic acid, o-dianisidine dihydrochloride, potassium iodide, acid black, and acid yellow were chosen as the indicators for simultaneous semi-quantitative measurement of glucose, lactate, and uric acid on a microPAD. Our approach was successfully applied to quantify glucose (0.5-20 mM), lactate (1-25 mM), and uric acid (0.1-7 mM) in clinically relevant ranges. The determination of glucose, lactate, and uric acid in control serum and urine samples was also performed to demonstrate the applicability of this device for biological sample analysis. Finally results for the multi-indicator and single indicator system were compared using untrained readers to demonstrate the improvements in accuracy achieved with the new system. 2010 Elsevier B.V. All rights reserved.

  19. Extracting forensic evidence from biometric devices

    NASA Astrophysics Data System (ADS)

    Geradts, Zeno J.; Ruifrok, Arnout C.

    2003-08-01

    Over the past few years, both large multinationals and governments have begun to contribute to even larger projects on biometric devices. Terrorist attacks in America and in other countries have highlighted the need for better identification systems for people as well as improved systems for controlling access to buildings. Another reason for investment in Research and Development in Biometric Devices, is the massive growth in internet-based systems -- whether for e-commerce, e-government or internal processes within organizations. The interface between the system and the user is routinely abused, as people have to remember many complex passwords and handle tokens of various types. In this paper an overview is given of the information that is important to know before an examination of such is systems can be done in a forensic proper way. In forensic evidence with biometric devices the forensic examiner should consider the possibilities of tampering with the biometric systems or the possibilities of unauthorized access before drawing conclusions.

  20. "Old Age and Loneliness: Cross-Sectional and Longitudinal Analyses in the Tampere Longitudinal Study on Aging"

    ERIC Educational Resources Information Center

    Jylha, Marja

    2004-01-01

    The purpose of this study was to examine whether older age is associated with increasing loneliness in people aged 60 and over. Data came from TamELSA, a population-based prospective longitudinal study in Tampere, Finland. The followup time was 20 years. Loneliness was measured by a single question--"Do you feel lonely?"--with the…

  1. Tamper asymmetry and its effect on transmission for x-ray driven opacity simulations

    DOE PAGES

    Morris, H. E.; Tregillis, I. L.; Hoffman, N. M.; ...

    2017-08-01

    This paper reports on synthetic transmission results from Lasnex [1] radiation-hydrodynamics simulations of opacity experiments carried out at Sandia National Laboratories' recently upgraded ZR facility. The focus is on experiments utilizing disk targets composed of a half-moon Fe/Mg mixture tamped on either end with 10- m CH and an additional 35- m beryllium tamper accessory on the end facing the spectrometer. Five x-ray sources with peak power ranging from 10 to 24 TW were used in the simulations to heat and backlight the opacity target. The dominant effect is that the beryllium behind the Fe/Mg mixture is denser and moremore » opaque than the beryllium unshielded by metal during the times of greatest importance for the transmission measurement for all drives. This causes the simulated transmission to be lower than expected, and this is most pronounced for the case using the lowest drive power. While beryllium has a low opacity, its areal density is sufficiently high such that the expected reduction of the measured transmission is significant. This situation leads to an overestimate of iron opacity by 10-215% for a photon energy range of 975- 1775 eV for the 10-TW case. It is shown that if the tamper conditions are known, the transmission through each component of the target can be calculated and the resulting opacity can be corrected.« less

  2. Vehicle energy conservation indicating device and process for use

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crump, J.M.

    A vehicle energy conservation indicating device comprises an integrated instrument cluster functioning basically as a nomographic computing mechanism. The odometer distance traveled indicator computing mechanism is linked with the fuel indicating gauge mechanism such that a three variable equation computing mechanism is obtained. The three variables are distance traveled, quantity of fuel consumed and distance traveled per unit of fuel consumed. Energy conservation is achieved by operating the vehicle under such performance conditions as to produce the highest possible value for distance traveled per unit of fuel consumed. The instrument panel cluster brings the operator's attention to focus upon andmore » continuously stimulated to conserving energy. Furthermore, the vehicle energy conservation indicating device can be adapted for recording these performance variables on tape type print out. The speedometer advises the vehicle operator when he is obeying or breaking the speed laws which are enforced and monitored by the police with specific punishment prescribed for violations of the law. At this time there is no comparable procedure for enforcing vehicle energy conservation. Thus, this direct read out of distance traveled per unit of energy will moderate the operation in an analogous manner similar to subliminal advertising. This device becomes the focal point of the instrument panel along with the speedometer, thereby providing constant motivation to obey both the speed and energy conservation laws.« less

  3. Tamper asymmetry and its effect on transmission for x-ray driven opacity simulations

    NASA Astrophysics Data System (ADS)

    Morris, H. E.; Tregillis, I. L.; Hoffman, N. M.; Sherrill, M. E.; Fontes, C. J.; Marshall, A. J.; Urbatsch, T. J.; Bradley, P. A.

    2017-09-01

    This paper reports on synthetic transmission results from Lasnex [Zimmerman and Kruer, Comments Plasma Phys. 2, 51 (1975)] radiation-hydrodynamics simulations of opacity experiments carried out at Sandia National Laboratories' recently upgraded ZR facility. The focus is on experiments utilizing disk targets composed of a half-moon Fe/Mg mixture tamped on either end with 10-μm CH and an additional 35-μm beryllium tamper accessory on the end facing the spectrometer. Five x-ray sources with peak power ranging from 10 to 24 TW were used in the simulations to heat and backlight the opacity target. The dominant effect is that the beryllium behind the Fe/Mg mixture is denser and more opaque than the beryllium unshielded by metal during the times of greatest importance for the transmission measurement for all drives. This causes the simulated transmission to be lower than expected, and this is most pronounced for the case using the lowest drive power. While beryllium has a low opacity, its areal density is sufficiently high such that the expected reduction of the measured transmission is significant. This situation leads to an overestimate of iron opacity by 10%-215% for a photon energy range of 975-1775 eV for the 10-TW case. It is shown that if the tamper conditions are known, the transmission through each component of the target can be calculated and the resulting opacity can be corrected.

  4. Child-resistant and tamper-resistant packaging: A systematic review to inform tobacco packaging regulation.

    PubMed

    Jo, Catherine L; Ambs, Anita; Dresler, Carolyn M; Backinger, Cathy L

    2017-02-01

    We aimed to investigate the effects of special packaging (child-resistant, adult-friendly) and tamper-resistant packaging on health and behavioral outcomes in order to identify research gaps and implications for packaging standards for tobacco products. We searched seven databases for keywords related to special and tamper-resistant packaging, consulted experts, and reviewed citations of potentially relevant studies. 733 unique papers were identified. Two coders independently screened each title and abstract for eligibility. They then reviewed the full text of the remaining papers for a second round of eligibility screening. Included studies investigated a causal relationship between type of packaging or packaging regulation and behavioral or health outcomes and had a study population composed of consumers. Studies were excluded on the basis of publication type, if they were not peer-reviewed, and if they had low external validity. Two reviewers independently coded each paper for study and methodological characteristics and limitations. Discrepancies were discussed and resolved. The review included eight studies: four assessing people's ability to access the contents of different packaging types and four evaluating the impact of packaging requirements on health-related outcomes. Child-resistant packaging was generally more difficult to open than non-child-resistant packaging. Child-resistant packaging requirements have been associated with reductions in child mortality. Child-resistant packaging holds the expectation to reduce tobacco product poisonings among children under six. Published by Elsevier Inc.

  5. Child-resistant and tamper-resistant packaging: A systematic review to inform tobacco packaging regulation

    PubMed Central

    Jo, Catherine L.; Ambs, Anita; Dresler, Carolyn M.; Backinger, Cathy L.

    2017-01-01

    Objective We aimed to investigate the effects of special packaging (child-resistant, adult-friendly) and tamper-resistant packaging on health and behavioral outcomes in order to identify research gaps and implications for packaging standards for tobacco products. Methods We searched seven databases for keywords related to special and tamper-resistant packaging, consulted experts, and reviewed citations of potentially relevant studies. 733 unique papers were identified. Two coders independently screened each title and abstract for eligibility. They then reviewed the full text of the remaining papers for a second round of eligibility screening. Included studies investigated a causal relationship between type of packaging or packaging regulation and behavioral or health outcomes and had a study population composed of consumers. Studies were excluded on the basis of publication type, if they were not peer-reviewed, and if they had low external validity. Two reviewers independently coded each paper for study and methodological characteristics and limitations. Discrepancies were discussed and resolved. Results The review included eight studies: four assessing people’s ability to access the contents of different packaging types and four evaluating the impact of packaging requirements on health-related outcomes. Child-resistant packaging was generally more difficult to open than non-child-resistant packaging. Child-resistant packaging requirements have been associated with reductions in child mortality. Conclusions Child-resistant packaging holds the expectation to reduce tobacco product poisonings among children under six. PMID:27939602

  6. Changes in the dispensing of opioid medications in Canada following the introduction of a tamper-deterrent formulation of long-acting oxycodone: a time series analysis.

    PubMed

    Gomes, Tara; Mastorakos, Andrea; Paterson, J Michael; Sketris, Ingrid; Caetano, Patricia; Greaves, Simon; Henry, David

    2017-11-22

    In February 2012, a reformulated tamper-deterrent form of long-acting oxycodone, OxyNeo, was introduced in Canada. We investigated the impact of the introduction of OxyNeo on patterns of opioid prescribing. We conducted population-based, cross-sectional analyses of opioid dispensing in Canada between 2008 and 2016. We estimated monthly community pharmacy dispensing of oral formulations of codeine, morphine, hydromorphone and oxycodone, and a transdermal formulation of fentanyl, and converted quantities to milligrams of morphine equivalents (MMEs) per 1000 population. We used time series analysis to evaluate the effect of the introduction of OxyNeo on these trends. National dispensing of long-acting opioids fell by 14.9% between February 2012 and April 2016, from 36 098 MMEs to 30 716 MMEs per 1000 population ( p < 0.01). This effect varied across Canada and was largest in Ontario (reduction of 22.8%) ( p = 0.01) and British Columbia (reduction of 30.0%) ( p = 0.01). The national rate of oxycodone dispensing fell by 46.4% after the introduction of OxyNeo ( p < 0.001); this was partially offset by an increase of 47.8% in hydromorphone dispensing ( p < 0.001). Although dispensing of immediate-release opioids was a substantial contributor to overall population opioid exposure across Canada, it was unaffected by the introduction of OxyNeo ( p > 0.05 in all provinces). The findings suggest that the introduction of a tamper-deterrent formulation of long-acting oxycodone in Canada, against a background of changing public drug benefits, was associated with sustained changes in selection of long-acting opioids but only small changes in the quantity of long-acting opioids dispensed. This illustrates the limited effect a tamper-deterrent formulation and associated coverage policy can have when other, non-tamper-deterrent alternatives are readily available. Copyright 2017, Joule Inc. or its licensors.

  7. Occupational exposure to electric and magnetic fields during work tasks at 110 kV substations in the Tampere region.

    PubMed

    Korpinen, Leena H; Pääkkönen, Rauno J

    2010-04-01

    The occupational exposure to electric and magnetic fields during various work tasks at seven 110 kV substations in Finland's Tampere region was studied. The aim was to investigate if the action values (10 kV/m for the E-field and 500 microT for the B-field) of the EU Directive 2004/40/EC were exceeded. Electric and magnetic fields were measured during the following work tasks: (1) walking or operating devices on the ground; (2) working from a service platform; (3) working around the power transformer on the ground or using a ladder; and (4) changing a bulb from a man hoist. In work task 2 "working from a service platform" the measured electric field (maximum value 16.6 kV/m) exceeded 10 kV/m in three cases. In the future it is important to study if the limit value (10 mA/m(2)) of Directive 2004/40/EC is exceeded at 110 kV substations. The occupational 500 microT action value of the magnetic flux density field (B-field) was not exceeded in any working situation.

  8. 33 CFR 164.40 - Devices to indicate speed and distance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., when the vessel is operating free from shallow water effect, and from the effects of wind, current, and...) Errors in the indicated distance run, when the vessel is operating free from shallow water effect, and... either through the water or over the ground. (b) The device must meet the following specifications: (1...

  9. 33 CFR 164.40 - Devices to indicate speed and distance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., when the vessel is operating free from shallow water effect, and from the effects of wind, current, and...) Errors in the indicated distance run, when the vessel is operating free from shallow water effect, and... either through the water or over the ground. (b) The device must meet the following specifications: (1...

  10. 33 CFR 164.40 - Devices to indicate speed and distance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., when the vessel is operating free from shallow water effect, and from the effects of wind, current, and...) Errors in the indicated distance run, when the vessel is operating free from shallow water effect, and... either through the water or over the ground. (b) The device must meet the following specifications: (1...

  11. 47 CFR 78.51 - Remote control operation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... control system shall be installed and protected in a manner designed to prevent tampering or operation by... transmissions and a carrier operated device which will give a continuous visual indication whenever the... necessary to insure proper operation. (4) The control circuits shall be so designed and installed that short...

  12. 47 CFR 78.51 - Remote control operation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... control system shall be installed and protected in a manner designed to prevent tampering or operation by... transmissions and a carrier operated device which will give a continuous visual indication whenever the... necessary to insure proper operation. (4) The control circuits shall be so designed and installed that short...

  13. Operator agency in process intervention: tampering versus application of tacit knowledge

    NASA Astrophysics Data System (ADS)

    Van Gestel, P.; Pons, D. J.; Pulakanam, V.

    2015-09-01

    Statistical process control (SPC) theory takes a negative view of adjustment of process settings, which is termed tampering. In contrast, quality and lean programmes actively encourage operators to acts of intervention and personal agency in the improvement of production outcomes. This creates a conflict that requires operator judgement: How does one differentiate between unnecessary tampering and needful intervention? Also, difficult is that operators apply tacit knowledge to such judgements. There is a need to determine where in a given production process the operators are applying tacit knowledge, and whether this is hindering or aiding quality outcomes. The work involved the conjoint application of systems engineering, statistics, and knowledge management principles, in the context of a case study. Systems engineering was used to create a functional model of a real plant. Actual plant data were analysed with the statistical methods of ANOVA, feature selection, and link analysis. This identified the variables to which the output quality was most sensitive. These key variables were mapped back to the functional model. Fieldwork was then directed to those areas to prospect for operator judgement activities. A natural conversational approach was used to determine where and how operators were applying judgement. This contrasts to the interrogative approach of conventional knowledge management. Data are presented for a case study of a meat rendering plant. The results identify specific areas where operators' tacit knowledge and mental model contribute to quality outcomes and untangles the motivations behind their agency. Also evident is how novice and expert operators apply their knowledge differently. Novices were focussed on meeting throughput objectives, and their incomplete understanding of the plant characteristics led them to inadvertently sacrifice quality in the pursuit of productivity in certain situations. Operators' responses to the plant are affected by

  14. Characterizing and Implementing Efficient Primitives for Privacy-Preserving Computation

    DTIC Science & Technology

    2015-07-01

    the mobile device. From this, the mobile will detect any tampering from the malicious party by a discrepancy in these returned values, eliminating...the need for an output MAC. If no tampering is detected , the mobile device then decrypts the output of computation. APPROVED FOR PUBLIC RELEASE...useful error messages when the compiler detects a problem with an application, making debugging the application significantly easier than with other

  15. 75 FR 875 - Guidance for Industry on New Contrast Imaging Indication Considerations for Devices and Approved...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-06

    ... imaging devices for use with imaging contrast agents or radiopharmaceuticals. FDA intends this guidance to..., for medical imaging devices for use with imaging contrast agents or radiopharmaceuticals. Further, the...] Guidance for Industry on New Contrast Imaging Indication Considerations for Devices and Approved Drug and...

  16. Towards the development of tamper-resistant, ground-based mobile sensor nodes

    NASA Astrophysics Data System (ADS)

    Mascarenas, David; Stull, Christopher; Farrar, Charles

    2011-11-01

    Mobile sensor nodes hold great potential for collecting field data using fewer resources than human operators would require and potentially requiring fewer sensors than a fixed-position sensor array. It would be very beneficial to allow these mobile sensor nodes to operate unattended with a minimum of human intervention. In order to allow mobile sensor nodes to operate unattended in a field environment, it is imperative that they be capable of identifying and responding to external agents that may attempt to tamper with, damage or steal the mobile sensor nodes, while still performing their data collection mission. Potentially hostile external agents could include animals, other mobile sensor nodes, or humans. This work will focus on developing control policies to help enable a mobile sensor node to identify and avoid capture by a hostile un-mounted human. The work is developed in a simulation environment, and demonstrated using a non-holonomic, ground-based mobile sensor node. This work will be a preliminary step toward ensuring the cyber-physical security of ground-based mobile sensor nodes that operate unattended in potentially unfriendly environments.

  17. On the designing of a tamper resistant prescription RFID access control system.

    PubMed

    Safkhani, Masoumeh; Bagheri, Nasour; Naderi, Majid

    2012-12-01

    Recently, Chen et al. have proposed a novel tamper resistant prescription RFID access control system, published in the Journal of Medical Systems. In this paper we consider the security of the proposed protocol and identify some existing weaknesses. The main attack is a reader impersonation attack which allows an active adversary to impersonate a legitimate doctor, e.g. the patient's doctor, to access the patient's tag and change the patient prescription. The presented attack is quite efficient. To impersonate a doctor, the adversary should eavesdrop one session between the doctor and the patient's tag and then she can impersonate the doctor with the success probability of '1'. In addition, we present efficient reader-tag to back-end database impersonation, de-synchronization and traceability attacks against the protocol. Finally, we propose an improved version of protocol which is more efficient compared to the original protocol while provides the desired security against the presented attacks.

  18. Passive device based on plastic optical fibers to determine the indices of refraction of liquids.

    PubMed

    Zubia, J; Garitaonaindía, G; Arrúe, J

    2000-02-20

    We have designed and measured a passive device based on plastic optical fibers (POF's) that one can use to determine the indices of refraction of liquids. A complementary software has also been designed to simulate the behavior of the device. We report on the theoretical model developed for the device, its implementation in a simulation software program, and the results of the simulation. A comparison of the experimental and calculated results is also shown and discussed.

  19. Measurement-device-independent quantum digital signatures

    NASA Astrophysics Data System (ADS)

    Puthoor, Ittoop Vergheese; Amiri, Ryan; Wallden, Petros; Curty, Marcos; Andersson, Erika

    2016-08-01

    Digital signatures play an important role in software distribution, modern communication, and financial transactions, where it is important to detect forgery and tampering. Signatures are a cryptographic technique for validating the authenticity and integrity of messages, software, or digital documents. The security of currently used classical schemes relies on computational assumptions. Quantum digital signatures (QDS), on the other hand, provide information-theoretic security based on the laws of quantum physics. Recent work on QDS Amiri et al., Phys. Rev. A 93, 032325 (2016);, 10.1103/PhysRevA.93.032325 Yin, Fu, and Zeng-Bing, Phys. Rev. A 93, 032316 (2016), 10.1103/PhysRevA.93.032316 shows that such schemes do not require trusted quantum channels and are unconditionally secure against general coherent attacks. However, in practical QDS, just as in quantum key distribution (QKD), the detectors can be subjected to side-channel attacks, which can make the actual implementations insecure. Motivated by the idea of measurement-device-independent quantum key distribution (MDI-QKD), we present a measurement-device-independent QDS (MDI-QDS) scheme, which is secure against all detector side-channel attacks. Based on the rapid development of practical MDI-QKD, our MDI-QDS protocol could also be experimentally implemented, since it requires a similar experimental setup.

  20. Continuous-variable Measurement-device-independent Quantum Relay Network with Phase-sensitive Amplifiers

    NASA Astrophysics Data System (ADS)

    Li, Fei; Zhao, Wei; Guo, Ying

    2018-01-01

    Continuous-variable (CV) measurement-device-independent (MDI) quantum cryptography is now heading towards solving the practical problem of implementing scalable quantum networks. In this paper, we show that a solution can come from deploying an optical amplifier in the CV-MDI system, aiming to establish a high-rate quantum network. We suggest an improved CV-MDI protocol using the EPR states coupled with optical amplifiers. It can implement a practical quantum network scheme, where the legal participants create the secret correlations by using EPR states connecting to an untrusted relay via insecure links and applying the multi-entangled Greenberger-Horne-Zeilinger (GHZ) state analysis at relay station. Despite the possibility that the relay could be completely tampered with and imperfect links are subject to the powerful attacks, the legal participants are still able to extract a secret key from network communication. The numerical simulation indicates that the quantum network communication can be achieved in an asymmetric scenario, fulfilling the demands of a practical quantum network. Furthermore, we show that the use of optical amplifiers can compensate the inherent imperfections and improve the secret key rate of the CV-MDI system.

  1. 76 FR 81363 - Temperature-Indicating Devices; Thermally Processed Low-Acid Foods Packaged in Hermetically...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-28

    ... Foods Packaged in Hermetically Sealed Containers; Correction AGENCY: Food and Drug Administration, HHS... containers to allow for use of other temperature-indicating devices, in addition to mercury-in-glass...

  2. Performance-oriented mobility assessment (POMA) balance score indicates need for assistive device.

    PubMed

    Mitchell, Kathryn D; Newton, Roberta A

    2006-06-01

    To determine (1) if older adults using an assistive device (AD) score lower on the Performance-Oriented Mobility Assessment (POMA) balance subscale (B-subscale) than individuals not using an AD; and (2) if a cut-score of 12 would indicate the need to use an AD. Elderly persons (n = 82, mean age = 82.1 years) were surveyed about AD use, health status, activity level and fall history. A one-time assessment of balance was conducted using the B-subscale. The 'arising task' was repeated to evaluate performance on the sit-to-stand task without using hands. A significant difference in B-subscale scores was observed between the two groups (AD; no AD), (P < 0.001). AD use was associated with lower activity level and health status. A cut-score of 12 points indicated device use (P = 0.000). The repeated 'arising task' demonstrated that 76.8% performed the task without using hands for support. Older adults using an AD will score lower on the B-subscale and report lower activity level and health status. A score of less than 12 on the B-subscale is indicative of AD need. Older adults who use an AD and self-report a falls history will score lower on the B-subscale than individuals using an AD and no reported history of falls.

  3. Process design and control of a twin screw hot melt extrusion for continuous pharmaceutical tamper-resistant tablet production.

    PubMed

    Baronsky-Probst, J; Möltgen, C-V; Kessler, W; Kessler, R W

    2016-05-25

    Hot melt extrusion (HME) is a well-known process within the plastic and food industries that has been utilized for the past several decades and is increasingly accepted by the pharmaceutical industry for continuous manufacturing. For tamper-resistant formulations of e.g. opioids, HME is the most efficient production technique. The focus of this study is thus to evaluate the manufacturability of the HME process for tamper-resistant formulations. Parameters such as the specific mechanical energy (SME), as well as the melt pressure and its standard deviation, are important and will be discussed in this study. In the first step, the existing process data are analyzed by means of multivariate data analysis. Key critical process parameters such as feed rate, screw speed, and the concentration of the API in the polymers are identified, and critical quality parameters of the tablet are defined. In the second step, a relationship between the critical material, product and process quality attributes are established by means of Design of Experiments (DoEs). The resulting SME and the temperature at the die are essential data points needed to indirectly qualify the degradation of the API, which should be minimal. NIR-spectroscopy is used to monitor the material during the extrusion process. In contrast to most applications in which the probe is directly integrated into the die, the optical sensor is integrated into the cooling line of the strands. This saves costs in the probe design and maintenance and increases the robustness of the chemometric models. Finally, a process measurement system is installed to monitor and control all of the critical attributes in real-time by means of first principles, DoE models, soft sensor models, and spectroscopic information. Overall, the process is very robust as long as the screw speed is kept low. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Improving Continuous-Variable Measurement-Device-Independent Multipartite Quantum Communication with Optical Amplifiers*

    NASA Astrophysics Data System (ADS)

    Guo, Ying; Zhao, Wei; Li, Fei; Huang, Duan; Liao, Qin; Xie, Cai-Lang

    2017-08-01

    The developing tendency of continuous-variable (CV) measurement-device-independent (MDI) quantum cryptography is to cope with the practical issue of implementing scalable quantum networks. Up to now, most theoretical and experimental researches on CV-MDI QKD are focused on two-party protocols. However, we suggest a CV-MDI multipartite quantum secret sharing (QSS) protocol use the EPR states coupled with optical amplifiers. More remarkable, QSS is the real application in multipartite CV-MDI QKD, in other words, is the concrete implementation method of multipartite CV-MDI QKD. It can implement a practical quantum network scheme, under which the legal participants create the secret correlations by using EPR states connecting to an untrusted relay via insecure links and applying the multi-entangled Greenberger-Horne-Zeilinger (GHZ) state analysis at relay station. Even if there is a possibility that the relay may be completely tampered, the legal participants are still able to extract a secret key from network communication. The numerical simulation indicates that the quantum network communication can be achieved in an asymmetric scenario, fulfilling the demands of a practical quantum network. Additionally, we illustrate that the use of optical amplifiers can compensate the partial inherent imperfections of detectors and increase the transmission distance of the CV-MDI quantum system.

  5. 76 FR 11891 - Temperature-Indicating Devices; Thermally Processed Low-Acid Foods Packaged in Hermetically...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-03

    ... contain mercury will eliminate concerns about potential contamination of the food or the processing... Vol. 76 Thursday, No. 42 March 3, 2011 Part III Department of Health and Human Services Food and Drug Administration 21 CFR Part 113 Temperature-Indicating Devices; Thermally Processed Low-Acid Foods...

  6. A novel device for quantitative measurement of chloride concentration by fluorescence indicator

    NASA Astrophysics Data System (ADS)

    Wang, Junsheng; Wu, Xudong; Chon, Chanhee; Gonska, Tanja; Li, Dongqing

    2012-02-01

    Cystic fibrosis (CF) is a life-threatening genetic disease. At present, the common method for diagnosis of CF is to detect the chloride concentration in sweat using ion-selective electrodes. However, the current sweat testing methods require a relatively large quantity of sweat sample, at least 25 µL, which is very difficult to obtain, especially for newborns. This paper presents a new method and a new device for rapid detection of the chloride concentration from a small volume of solution. In this method, the chloride concentration is determined quantitatively by the fluorescence intensity of MQAE, a chloride ion fluorescent indicator. In this device, the sample is carried by a small piece of filter paper on a cover glass exposed to an UV LED light source. The resulting fluorescent signals are detected by a Si photodiode. Data acquisition and processing are accomplished by LabVIEW software in a PDA. Based on the Stern-Volmer relationship, the effects of different parameters on the fluorescence intensity were analyzed. The observed significant difference between 40 and 60 mM (the borderline of chloride concentration for CF) is discussed in this paper. The results show that detection can be completed within 10 s. The minimum detectable volume of the chloride solution is 1 μL. The novel method and the device are of great potential for CF diagnosis.

  7. Opioid use following the introduction of an extended-release oxycodone formulation with tamper-resistant properties: Prospective historical chart review in methadone-maintained patients.

    PubMed

    Sankey, Christopher; Setnik, Beatrice; Harsanyi, Zoltan; Michalko, Ken; Yang, Zejiang; Geoffroy, Pierre

    2016-01-01

    Emerging data are demonstrating that tamper-resistant opioids may play an important role in changing prescription opioid abuse behaviors. This study was a chart review to examine if the reformulation of OxyContin® into a version with tamper-resistant properties (OxyNEO®) had an impact on oxycodone-positive urine drug screens (UDSs) in opioid-dependent patients receiving methadone maintenance therapy (MMT). The historical element of this study examined 250 eligible charts from patients on MMT who had data during the time periods when only OxyContin was available (baseline period), during the transition to OxyNEO, and when only OxyNEO was available. The prospective element included an exploratory questionnaire regarding retrospective opioid use. The study was conducted at three methadone clinics, in Oshawa, Peterborough, and Scarborough in Ontario, Canada. Male and female patients were eligible if they had a diagnosis of opioid dependency, received MMT, and had at least one oxycodone-positive UDS during the baseline period. This was a noninterventional study. The main outcome was the number of oxycodonepositive UDSs. The results demonstrated a marked reduction in oxycodone-positive UDSs that showed stepwise, statistically significant decreases during the transition and post-OxyContin periods relative to baseline. While the oxycodone-positive UDS results were decreasing, morphine-related-positive UDSs remained relatively stable during the same periods. There were no significant gender differences noted. The introduction of OxyNEO was associated with a statistically significant reduction in oxycodone exposure in a population of methadone-maintained patients.

  8. Planar ultra thin glass seals with optical fiber interface for monitoring tamper attacks on security eminent components

    NASA Astrophysics Data System (ADS)

    Thiel, M.; Flachenecker, G.; Schade, W.; Gorecki, C.; Thoma, A.; Rathje, R.

    2017-11-01

    Optical seals consisting of waveguide Bragg grating sensor structures in ultra thin glass transparencies have been developed to cover security relevant objects for detection of unauthorized access. For generation of optical signature in the seals, femtosecond laser pulses were used. The optical seals were connected with an optical fiber to enable external read out of the seal. Different attack scenarios for getting undetected access to the object, covered by the seal, were proven and evaluated. The results presented here, verify a very high level of security. An unauthorized detaching and subsequent replacement by original or copy of the seals for tampering would be accompanied with a very high technological effort, posing a substantial barrier towards an attacker. Additionally, environmental influences like temperature effects have a strong but reproducible influence on signature, which in context of a temperature reference database increases the level of security significantly.

  9. An Outbreak of Norovirus Infections Among Lunch Customers at a Restaurant, Tampere, Finland, 2015.

    PubMed

    Vo, Thuan Huu; Okasha, Omar; Al-Hello, Haider; Polkowska, Aleksandra; Räsänen, Sirpa; Bojang, Merja; Nuorti, J Pekka; Jalava, Katri

    2016-09-01

    On January 29, 2015, the city of Tampere environmental health officers were informed of a possible foodborne outbreak among customers who had eaten lunch in restaurant X. Employees of electric companies A and B had a sudden onset of gastrointestinal symptoms. We conducted a retrospective cohort study to identify the vehicle, source, and causative agent of the outbreak. A case was defined as an employee of companies A or B with diarrhea and/or vomiting who ate lunch at Restaurant X on January 26, 2015. All employees of the companies attending the implicated lunch were invited to participate in the cohort study. Environmental investigation was conducted. Twenty-one responders were included in statistical analysis, of which 11 met with the case definition. Of the 15 food items consumed by participants, four food items were associated with gastroenteritis. Of four kitchen staff, three tested positive for norovirus GIP7, the strain was found earlier in the community. No patient samples were obtained. Level of hygiene in the kitchen was inadequate. Infected kitchen staff probably transmitted norovirus by inadequate hygiene practices. No new cases associated with Restaurant X were reported after the hygiene practices were improved.

  10. High-performance combination method of electric network frequency and phase for audio forgery detection in battery-powered devices.

    PubMed

    Savari, Maryam; Abdul Wahab, Ainuddin Wahid; Anuar, Nor Badrul

    2016-09-01

    Audio forgery is any act of tampering, illegal copy and fake quality in the audio in a criminal way. In the last decade, there has been increasing attention to the audio forgery detection due to a significant increase in the number of forge in different type of audio. There are a number of methods for forgery detection, which electric network frequency (ENF) is one of the powerful methods in this area for forgery detection in terms of accuracy. In spite of suitable accuracy of ENF in a majority of plug-in powered devices, the weak accuracy of ENF in audio forgery detection for battery-powered devices, especially in laptop and mobile phone, can be consider as one of the main obstacles of the ENF. To solve the ENF problem in terms of accuracy in battery-powered devices, a combination method of ENF and phase feature is proposed. From experiment conducted, ENF alone give 50% and 60% accuracy for forgery detection in mobile phone and laptop respectively, while the proposed method shows 88% and 92% accuracy respectively, for forgery detection in battery-powered devices. The results lead to higher accuracy for forgery detection with the combination of ENF and phase feature. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Current status of device-assisted enteroscopy: Technical matters, indication, limits and complications

    PubMed Central

    Riccioni, Maria Elena; Urgesi, Riccardo; Cianci, Rossella; Bizzotto, Alessandra; Galasso, Domenico; Costamagna, Guido

    2012-01-01

    Enteroscopy, defined as direct visualization of the small bowel with the use of a fiberoptic or capsule endoscopy, has progressed considerably over the past several years. The need for endoscopic access to improve diagnosis and treatment of small bowel disease has led to the development of novel technologies one of which is non-invasive, the video capsule, and a type of invasive technique, the device-assisted enteroscopy. In particular, the device-assisted enteroscopy consists then of three different types of instruments all able to allow, in skilled hands, to display partially or throughout its extension (if necessary) the small intestine. Newer devices, double balloon, single balloon and spiral endoscopy, are just entering clinical use. The aim of this article is to review recent advances in small bowel enteroscopy, focusing on indications, modifications to improve imaging and techniques, pitfalls, and clinical applications of the new instruments. With new technologies, the trials and tribulations of learning new endoscopic skills and determining their role in the diagnosis and treatment of small bowel disease come. Identification of small bowel lesions has dramatically improved. Studies are underway to determine the best strategy to apply new enteroscopy technologies for the diagnosis and management of small bowel disease, particularly obscure bleeding. Vascular malformations such as angiectasis and small bowel neoplasms as adenocarcinoma or gastrointestinal stromal tumors. Complete enteroscopy of the small bowel is now possible. However, because of the length of the small bowel, endoscopic examination and therapeutic maneuvers require significant skill, radiological assistance, the use of deep sedation with the assistance of the anesthetist. Prospective randomized studies are needed to guide diagnostic testing and therapy with these new endoscopic techniques. PMID:23189216

  12. Central venous access in children: indications, devices, and risks.

    PubMed

    Ares, Guillermo; Hunter, Catherine J

    2017-06-01

    Central venous catheters (CVCs) have a prominent role in the diagnostic and therapy of neonates and children. Herein, we describe the multiple indications for CVC use and the different devices available for central venous access. Given the prevalent use of CVCs, healthcare systems are focused on reducing complications from their use, particularly central line-associated bloodstream infections (CLABSIs). The most up-to-date information available sheds light on best practices and future areas of investigation. Large systematic reviews of randomized trials suggest that ultrasound guidance for placement of CVCs in children is safer than using blind technique, at least for internal jugular vein access. Appropriate catheter tip placement is associated with decreased complications. Furthermore, the prophylactic use of ethanol lock between cycles of parenteral nutrition administration has reduced the rates of CLABSI. A recent randomized trial in pediatric CVCs showed a benefit with antibiotic-coated CVCs. Based on the available evidence, multiple techniques for CVC placement are still valid, including the landmark technique based on practitioner experience, but ultrasound guidance has been shown to decrease complications from line placement. Adherence to CVC care protocols is essential in reducing infectious complications.

  13. Believing Your Eyes: Strengthening the Reliability of Tags and Seals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brim, Cornelia P.; Denlinger, Laura S.

    2013-07-01

    NNSA’s Office of Nonproliferation and International Security (NIS) is working together with scientific experts at the DOE national laboratories to develop the tools needed to safeguard and secure nuclear material from diversion, theft, and sabotage--tasks critical to support future arms control treaties that may involve the new challenge of monitoring nuclear weapons dismantlement. Use of optically stimulated luminescent material is one method to enhance the security and robustness of existing tamper indicating devices such as tags and seals.

  14. Tactile Speech Indicator: Adaptive Telephone Device for Deaf-Blind Clients.

    ERIC Educational Resources Information Center

    Lynch, M. R.

    1990-01-01

    This article describes basic applications of an adaptive telephone device for deaf-blind persons with speaking voices. The deaf-blind caller poses questions requiring one-word answers, and the device vibrates in response to touch-tone pulses from the other party. Specific suggestions for such uses as making appointments and emergency calls are…

  15. Transtech PQI 301 pavement quality indicator device evaluation.

    DOT National Transportation Integrated Search

    2010-10-01

    The PQI 301 Asphalt Density device, developed by Transtech Systems, Inc., was evaluated by MDOT to determine if it could be used in lieu of the currently required nuclear density gauge. Nuclear density gauges require MDOT personnel to have a license,...

  16. Connector device for building integrated photovoltaic device

    DOEpatents

    Keenihan, James R.; Langmaid, Joe A.; Eurich, Gerald K.; Lesniak, Michael J.; Mazor, Michael H.; Cleerman, Robert J.; Gaston, Ryan S.

    2015-11-10

    The present invention is premised upon a connector device and method that can more easily electrically connect a plurality of PV devices or photovoltaic system components and/or locate these devices/components upon a building structure. It also may optionally provide some additional sub-components (e.g. at least one bypass diode and/or an indicator means) and may enhance the serviceability of the device.

  17. Connector device for building integrated photovoltaic device

    DOEpatents

    Keenihan, James R.; Langmaid, Joseph A.; Eurich, Gerald K.; Lesniak, Michael J.; Mazor, Michael H.; Cleereman, Robert J.; Gaston, Ryan S.

    2014-06-03

    The present invention is premised upon a connector device and method that can more easily electrically connect a plurality of PV devices or photovoltaic system components and/or locate these devices/components upon a building structure. It also may optionally provide some additional sub-components (e.g. at least one bypass diode and/or an indicator means) and may enhance the serviceability of the device.

  18. [A study on the thermographic diagnosis of vibration disease of tie-tamper operators in the Japanese National Railways].

    PubMed

    Hirahata, H

    1984-01-01

    There have been many studies of thermographic diagnosis of vibration disease, but few of them seem to have discussed tie-tamping machines as a cause. This study focuses on thermographic diagnosis of vibration disease in tie-tamper operators of the Japanese National Railways. In the diagnosis the subject's both hands were immersed in water at 10 degrees C for 3 minutes before being examined. Variables such as season, age, type of vibration tool used and total operating time were considered. These were selected as outside variables and thermographic results as dependent variables, in Quantification Method II. Season and confirmation of vibration disease were found to have a relationship to thermographic scaling, but no such relationship was found for age, type of vibration tool used, or total operating time. A cross-analysis of variables confirmed the relationship with season, and revealed that there were fewer confirmed cases of vibration disease in spring and summer than in fall and winter. It was finally concluded that thermographic analysis is more reliable in colder weather.

  19. Uranium Enrichment Safeguards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demuth, Scott F.; Trahan, Alexis Chanel

    2017-06-26

    DIV of facility layout, material flows, and other information provided in the DIQ. Material accountancy through an annual PIV and a number of interim inventory verifications, including UF6 cylinder identification and counting, NDA of cylinders, and DA on a sample collection of UF6. Application of C/S technologies utilizing seals and tamper-indicating devices (TIDs) on cylinders, containers, storage rooms, and IAEA instrumentation to provide continuity of knowledge between inspection. Verification of the absence of undeclared material and operations, especially HEU production, through SNRIs, LFUA of cascade halls, and environmental swipe sampling

  20. Identification of Measures and Indicators for the IT Security of Networked Medical Devices: A Delphi Study.

    PubMed

    Leber, Stefan; Ammenwerth, Elske

    2017-01-01

    The networking of medical devices or systems in a hospital network is the foundation for modern medical diagnostics and therapy. This, however, makes possible numerous hazards that could lead to risks for patients, clinical processes or data and information. The aim of the work was to develop a catalogue of measures and indicators for the effective support of the IT risk management process in a health facility. Through a qualitative and quantitative Delphi study among 21 experts, it was possible to identify an initial 51 practice-relevant measures of IT risk management that a hospital should implement. Additionally, 27 indicators were defined which can be used to measure the impact of these measures. Of the 51 measures, 35 were seen as especially important, particularly organizational measures. Of the 27 indicators, six were seen as especially important, particularly indicators to measure networking effectiveness. The study also investigated the impact of the measures on the indicators. A case study is planned to investigate the practicability of the identified measures and indicators.

  1. eBiometrics: an enhanced multi-biometrics authentication technique for real-time remote applications on mobile devices

    NASA Astrophysics Data System (ADS)

    Kuseler, Torben; Lami, Ihsan; Jassim, Sabah; Sellahewa, Harin

    2010-04-01

    The use of mobile communication devices with advance sensors is growing rapidly. These sensors are enabling functions such as Image capture, Location applications, and Biometric authentication such as Fingerprint verification and Face & Handwritten signature recognition. Such ubiquitous devices are essential tools in today's global economic activities enabling anywhere-anytime financial and business transactions. Cryptographic functions and biometric-based authentication can enhance the security and confidentiality of mobile transactions. Using Biometric template security techniques in real-time biometric-based authentication are key factors for successful identity verification solutions, but are venerable to determined attacks by both fraudulent software and hardware. The EU-funded SecurePhone project has designed and implemented a multimodal biometric user authentication system on a prototype mobile communication device. However, various implementations of this project have resulted in long verification times or reduced accuracy and/or security. This paper proposes to use built-in-self-test techniques to ensure no tampering has taken place on the verification process prior to performing the actual biometric authentication. These techniques utilises the user personal identification number as a seed to generate a unique signature. This signature is then used to test the integrity of the verification process. Also, this study proposes the use of a combination of biometric modalities to provide application specific authentication in a secure environment, thus achieving optimum security level with effective processing time. I.e. to ensure that the necessary authentication steps and algorithms running on the mobile device application processor can not be undermined or modified by an imposter to get unauthorized access to the secure system.

  2. A Tamper-Resistant and Portable Healthcare Folder

    PubMed Central

    Anciaux, Nicolas; Berthelot, Morgane; Braconnier, Laurent; Bouganim, Luc; De la Blache, Martine; Gardarin, Georges; Kesmarszky, Philippe; Lartigue, Sophie; Navarre, Jean-François; Pucheral, Philippe; Vandewalle, Jean-Jacques; Zeitouni, Karine

    2008-01-01

    Electronic health record (EHR) projects have been launched in most developed countries to increase the quality of healthcare while decreasing its cost. The benefits provided by centralizing the healthcare information in database systems are unquestionable in terms of information quality, availability, and protection against failure. Yet, patients are reluctant to give to a distant server the control over highly sensitive data (e.g., data revealing a severe or shameful disease). This paper capitalizes on a new hardware portable device, associating the security of a smart card to the storage capacity of a USB key, to give back to the patient the control over his medical data. This paper shows how this device can complement a traditional EHR server to (1) protect and share highly sensitive data among trusted parties and (2) provide a seamless access to the data even in disconnected mode. The proposed architecture is experimented in the context of a medicosocial network providing medical care and social services at home for elderly people. PMID:18615200

  3. Noncontacting devices to indicate deflection and vibration of turbopump internal rotating parts

    NASA Technical Reports Server (NTRS)

    Hamilton, D. B.; Ensminger, D.; Grieser, D. R.; Plummer, A. M.; Saccocio, E. J.; Kissel, J. W.

    1973-01-01

    The research is reported which was conducted to develop devices for measuring vibrations and deflections of parts, such as impellers, shafts, turbine wheels, and inducers in operating turbopumps. Three devices were developed to the breadboard stage: ultrasonic Doppler transducer, flash X-rays, and light-pipe reflectance. It was found that the X-ray technique is applicable to the shaft assembly and the turbine seal of the J-2 pump, and the light-pipe-reflectance device appears to be ideal for cryogenic pump sections.

  4. Patient Preferences for Device-Aided Treatments Indicated for Advanced Parkinson Disease.

    PubMed

    Marshall, Thomas; Pugh, Amy; Fairchild, Angelyn; Hass, Steven

    2017-12-01

    Effective treatment for advanced Parkinson disease (PD) uncontrolled with oral medication includes device-aided therapies such as deep brain stimulation (DBS) and continuous levodopa-carbidopa infusion to the duodenum via a portable pump. Our objective was to quantify patient preferences for attributes of these device-aided treatments. We administered a Web-enabled survey to 401 patients in the United States. A discrete-choice experiment (DCE) was used to evaluate patients' willingness to accept tradeoffs among efficacy, tolerability, and convenience of alternative treatments. DCE data were analyzed using random-parameters logit. Best-worst scaling (BWS) was used to elicit the relative importance of device-specific attributes. Conditional logit was used to analyze the BWS data. We tested for differences in preferences among subgroups of patients. Improving ability to think clearly was twice as important as a 6-hour-per-day improvement in control of movement symptoms. After controlling for efficacy, treatment delivered via portable infusion pump was preferred over DBS, and both devices were preferred to oral therapy with poor symptom control. Patients were most concerned about device attributes relating to risk of stroke, difficulty thinking, and neurosurgery. Avoiding surgery to insert a wire in the brain was more important than avoiding surgery to insert a tube into the small intestine. Some differences in preferences among subgroups were statistically, but not qualitatively, significant. This study clarifies the patient perspective in therapeutic choices for advanced PD. These findings may help improve communication between patients and providers and also provide evidence on patient preferences to inform regulatory and access decisions. Copyright © 2017. Published by Elsevier Inc.

  5. 14 CFR 25.699 - Lift and drag device indicator.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25... each lift or drag device having a separate control in the cockpit to adjust its position. In addition... controls must be clearly marked to identify this range of extension. [Amdt. 25-23, 35 FR 5675, Apr. 8, 1970] ...

  6. 14 CFR 25.699 - Lift and drag device indicator.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25... each lift or drag device having a separate control in the cockpit to adjust its position. In addition... controls must be clearly marked to identify this range of extension. [Amdt. 25-23, 35 FR 5675, Apr. 8, 1970] ...

  7. 14 CFR 25.699 - Lift and drag device indicator.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25... each lift or drag device having a separate control in the cockpit to adjust its position. In addition... controls must be clearly marked to identify this range of extension. [Amdt. 25-23, 35 FR 5675, Apr. 8, 1970] ...

  8. 21 CFR 870.1660 - Indicator injector.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Indicator injector. 870.1660 Section 870.1660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1660 Indicator injector. (a...

  9. 21 CFR 870.1660 - Indicator injector.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Indicator injector. 870.1660 Section 870.1660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1660 Indicator injector. (a...

  10. The indirect detection of bleach (sodium hypochlorite) in beverages as evidence of product tampering.

    PubMed

    Jackson, David S; Crockett, David F; Wolnik, Karen A

    2006-07-01

    Bleach (sodium hypochlorite) has been identified as the adulterant in a relatively large number of product tamperings that have been investigated by the Forensic Chemistry Center (FCC) of the U.S. Food and Drug Administration. In this work, household bleach was added to 23 different beverages at each of three levels. The impact of sodium hypochlorite on these beverages over a 13-day study period was evaluated using the following techniques: diphenylamine spot test for oxidizing agents, potassium iodide-starch test paper for oxidizing agents, pH, iodometric titration for quantitating hypochlorite, ion chromatography for chloride and chlorate quantitation, automated headspace sampling with gas chromatography-flame ionization detection (GC-FID) for determination of chloroform, and visual and organoleptic observations. This study has shown that hypochlorite is fragile when added to most common beverages and typically breaks down either partially or completely over time. In cases where a beverage is suspected of being adulterated with bleach but tests for hypochlorite are negative, it is still possible to characterize the product to demonstrate that the results are consistent with the addition of bleach. An adulterated product will give a positive test for oxidizing agents using the diphenylamine spot test. It is likely that the pH of the adulterated product will be higher than a control of that product. Ion chromatographic analysis shows elevated chloride and chlorate as compared with a control. And, chloroform may also be detected by GC-FID especially if the beverage that was adulterated contains citric acid.

  11. Authentication via wavefront-shaped optical responses

    NASA Astrophysics Data System (ADS)

    Eilers, Hergen; Anderson, Benjamin R.; Gunawidjaja, Ray

    2018-02-01

    Authentication/tamper-indication is required in a wide range of applications, including nuclear materials management and product counterfeit detection. State-of-the-art techniques include reflective particle tags, laser speckle authentication, and birefringent seals. Each of these passive techniques has its own advantages and disadvantages, including the need for complex image comparisons, limited flexibility, sensitivity to environmental conditions, limited functionality, etc. We have developed a new active approach to address some of these short-comings. The use of an active characterization technique adds more flexibility and additional layers of security over current techniques. Our approach uses randomly-distributed nanoparticles embedded in a polymer matrix (tag/seal) which is attached to the item to be secured. A spatial light modulator is used to adjust the wavefront of a laser which interacts with the tag/seal, and a detector is used to monitor this interaction. The interaction can occur in various ways, including transmittance, reflectance, fluorescence, random lasing, etc. For example, at the time of origination, the wavefront-shaped reflectance from a tag/seal can be adjusted to result in a specific pattern (symbol, words, etc.) Any tampering with the tag/seal would results in a disturbance of the random orientation of the nanoparticles and thus distort the reflectance pattern. A holographic waveplate could be inserted into the laser beam for verification. The absence/distortion of the original pattern would then indicate that tampering has occurred. We have tested the tag/seal's and authentication method's tamper-indicating ability using various attack methods, including mechanical, thermal, and chemical attacks, and have verified our material/method's robust tamper-indicating ability.

  12. 21 CFR 872.1850 - Lead-lined position indicator.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Lead-lined position indicator. 872.1850 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1850 Lead-lined position indicator. (a) Identification. A lead-lined position indicator is a cone-shaped device lined with lead that is attached to a...

  13. 21 CFR 872.1850 - Lead-lined position indicator.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Lead-lined position indicator. 872.1850 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1850 Lead-lined position indicator. (a) Identification. A lead-lined position indicator is a cone-shaped device lined with lead that is attached to a...

  14. 21 CFR 872.1850 - Lead-lined position indicator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Lead-lined position indicator. 872.1850 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1850 Lead-lined position indicator. (a) Identification. A lead-lined position indicator is a cone-shaped device lined with lead that is attached to a...

  15. 21 CFR 872.1850 - Lead-lined position indicator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Lead-lined position indicator. 872.1850 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1850 Lead-lined position indicator. (a) Identification. A lead-lined position indicator is a cone-shaped device lined with lead that is attached to a...

  16. 29 CFR 1910.103 - Hydrogen.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... containers, pressure regulators, safety relief devices, manifolds, interconnecting piping and controls. The... against physical damage and against tampering. (d) Cabinets or housings containing hydrogen control or... valve shall be of the remote control type with no connections, flanges, or other appurtenances (other...

  17. 29 CFR 1910.103 - Hydrogen.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... containers, pressure regulators, safety relief devices, manifolds, interconnecting piping and controls. The... against physical damage and against tampering. (d) Cabinets or housings containing hydrogen control or... valve shall be of the remote control type with no connections, flanges, or other appurtenances (other...

  18. Wireless device monitoring methods, wireless device monitoring systems, and articles of manufacture

    DOEpatents

    McCown, Steven H [Rigby, ID; Derr, Kurt W [Idaho Falls, ID; Rohde, Kenneth W [Idaho Falls, ID

    2012-05-08

    Wireless device monitoring methods, wireless device monitoring systems, and articles of manufacture are described. According to one embodiment, a wireless device monitoring method includes accessing device configuration information of a wireless device present at a secure area, wherein the device configuration information comprises information regarding a configuration of the wireless device, accessing stored information corresponding to the wireless device, wherein the stored information comprises information regarding the configuration of the wireless device, comparing the device configuration information with the stored information, and indicating the wireless device as one of authorized and unauthorized for presence at the secure area using the comparing.

  19. 30 CFR 23.7 - Specific requirements for approval.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., and the terminals and the connections thereto shall be so arranged and protected as to preclude meddling, tampering, or making other electrical connections with them. (e) Manufacturers shall furnish adequate instructions for the installation and connection of telephones and signal devices in order that...

  20. 30 CFR 23.7 - Specific requirements for approval.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., and the terminals and the connections thereto shall be so arranged and protected as to preclude meddling, tampering, or making other electrical connections with them. (e) Manufacturers shall furnish adequate instructions for the installation and connection of telephones and signal devices in order that...

  1. 40 CFR 51.369 - Improving repair effectiveness.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... technical questions that arise in the repair process, and answer questions related to the legal requirements of State and Federal law with regard to emission control device tampering, engine switching, or... vehicles for retest. Performance monitoring shall include statistics on the number of vehicles submitted...

  2. 21 CFR 864.8150 - Calibrator for cell indices.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Calibrator for cell indices. 864.8150 Section 864...) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8150 Calibrator for cell indices. (a) Identification. A calibrator for cell indices is a device that approximates whole blood or...

  3. 21 CFR 864.8150 - Calibrator for cell indices.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Calibrator for cell indices. 864.8150 Section 864...) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8150 Calibrator for cell indices. (a) Identification. A calibrator for cell indices is a device that approximates whole blood or...

  4. 21 CFR 864.8150 - Calibrator for cell indices.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Calibrator for cell indices. 864.8150 Section 864...) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8150 Calibrator for cell indices. (a) Identification. A calibrator for cell indices is a device that approximates whole blood or...

  5. 21 CFR 864.8150 - Calibrator for cell indices.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Calibrator for cell indices. 864.8150 Section 864...) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8150 Calibrator for cell indices. (a) Identification. A calibrator for cell indices is a device that approximates whole blood or...

  6. 21 CFR 864.8150 - Calibrator for cell indices.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Calibrator for cell indices. 864.8150 Section 864...) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8150 Calibrator for cell indices. (a) Identification. A calibrator for cell indices is a device that approximates whole blood or...

  7. An indicator device for monitoring of room illuminance level in the radiological image viewing environment.

    PubMed

    Azlan, C A; Ng, K H; Anandan, S; Nizam, M S

    2006-09-01

    Illuminance level in the softcopy image viewing room is a very important factor to optimize productivity in radiological diagnosis. In today's radiological environment, the illuminance measurements are normally done during the quality control procedure and performed annually. Although the room is equipped with dimmer switches, radiologists are not able to decide the level of illuminance according to the standards. The aim of this study is to develop a simple real-time illuminance detector system to assist the radiologists in deciding an adequate illuminance level during radiological image viewing. The system indicates illuminance in a very simple visual form by using light emitting diodes. By employing the device in the viewing room, illuminance level can be monitored and adjusted effectively.

  8. 75 FR 27318 - Notice of Intent To Grant an Exclusive License; FIXMO U.S. INC.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-14

    ..., license to practice the following Government-Owned invention as described in U.S. Patent Application Serial No.11/999,050 entitled: ``Method of Tamper Detection for Digital Device,'' which was allowed by... above-mentioned invention is assigned to the United States Government as represented by the National...

  9. Low latency counter event indication

    DOEpatents

    Gara, Alan G [Mount Kisco, NY; Salapura, Valentina [Chappaqua, NY

    2008-09-16

    A hybrid counter array device for counting events with interrupt indication includes a first counter portion comprising N counter devices, each for counting signals representing event occurrences and providing a first count value representing lower order bits. An overflow bit device associated with each respective counter device is additionally set in response to an overflow condition. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits. An operatively coupled control device monitors each associated overflow bit device and initiates incrementing a second count value stored at a corresponding memory location in response to a respective overflow bit being set. The incremented second count value is compared to an interrupt threshold value stored in a threshold register, and, when the second counter value is equal to the interrupt threshold value, a corresponding "interrupt arm" bit is set to enable a fast interrupt indication. On a subsequent roll-over of the lower bits of that counter, the interrupt will be fired.

  10. Low latency counter event indication

    DOEpatents

    Gara, Alan G.; Salapura, Valentina

    2010-08-24

    A hybrid counter array device for counting events with interrupt indication includes a first counter portion comprising N counter devices, each for counting signals representing event occurrences and providing a first count value representing lower order bits. An overflow bit device associated with each respective counter device is additionally set in response to an overflow condition. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits. An operatively coupled control device monitors each associated overflow bit device and initiates incrementing a second count value stored at a corresponding memory location in response to a respective overflow bit being set. The incremented second count value is compared to an interrupt threshold value stored in a threshold register, and, when the second counter value is equal to the interrupt threshold value, a corresponding "interrupt arm" bit is set to enable a fast interrupt indication. On a subsequent roll-over of the lower bits of that counter, the interrupt will be fired.

  11. Tagging RDT&E. Volume 1. Technology Assessment and Development Reports

    DTIC Science & Technology

    1994-03-01

    weapon system component could have a unique, counterfeit and transfer resistant, and tamper indicating identifier (or tag), inspectors could...the random nature of the reflective surfaces on each particle, the tag is highly resistant to counterfeiting . Sym t, n- BDM Jnvolvement RPT Sandia...layers) that tampering has occurred. A reflective particle (RP) disk was added by PNL to increase the difficulty of counterfeiting the tag and to make

  12. Noncontacting device to indicate deflection of turbopump internal rotating parts

    NASA Technical Reports Server (NTRS)

    Hamilton, D. B.; Grieser, D. R.; Plummer, A. M.; Ensminger, D.; Saccacio, E. J.

    1972-01-01

    Phase 2 (development) which was concluded for the ultrasonic Doppler device and the light-pipe-reflectance device is reported. An ultrasonic Doppler breadboard system was assembled which accurately measured runout in the J-2 LOX pump impeller during operation. The transducer was mounted on the outside of the pump volute using a C-clamp. Vibration was measured by conducting the ultrasonic wave through the volute housing and through the fluid in the volute to the impeller surface. The impeller vibration was also measured accurately using the light-pipe probe mounted in an elastomeric-gland fitting in the pump case. A special epoxy resin developed for cryogenic applications was forced into the end of the fiber-optic probe to retain the fibers. Subsequently, the probe suffered no damage after simultaneous exposure to 2150 psi and 77 F. Preliminary flash X-radiographs were taken of the turbine wheel and the shaft-bearing-seal assembly, using a 2-megavolt X-ray unit. Reasonable resolution and contrast was obtained. A fast-neutron detector was fabricated and sensitivity was measured. The results demonstrated that the technique is feasible for integrated-time measurements requiring, perhaps, 240 revolutions to obtain sufficient exposure at 35,000 rpm. The experimental verification plans are included.

  13. A device for testing cables

    NASA Technical Reports Server (NTRS)

    Hayhurst, Arthur Ray (Inventor)

    1993-01-01

    A device for testing current paths is attachable to a conductor. The device automatically checks the current paths of the conductor for continuity of a center conductor, continuity of a shield, and a short circuit between the shield and the center conductor. The device includes a pair of connectors and a circuit to provide for testing of the conductive paths of a cable to be tested with the circuit paths of the circuit. The circuit paths in the circuit include indicators to simultaneously indicate the results of the testing.

  14. Privacy-Preserving Authentication Using a Double Pseudonym for Internet of Vehicles.

    PubMed

    Cui, Jie; Xu, Wenyu; Zhong, Hong; Zhang, Jing; Xu, Yan; Liu, Lu

    2018-05-07

    The Internet of Vehicles (IoV) plays an important role in smart transportation to reduce the drivers’s risk of having an accident and help them manage small emergencies. Therefore, security and privacy issues of the message in the tamper proof device (TPD) broadcasted to other vehicles and roadside units (RSUs) have become an important research subject in the field of smart transportation. Many authentication schemes are proposed to tackle the challenges above and most of them are heavy in computation and communication. In this paper, we propose a novel authentication scheme that utilizes the double pseudonym method to hide the real identity of vehicles and adopts the dynamic update technology to periodically update the information (such as member secret, authentication key, internal pseudo-identity) stored in the tamper-proof device to prevent the side-channel attack. Because of not using bilinear pairing, our scheme yields a better performance in terms of computation overhead and communication overhead, and is more suitable to be applied in the Internet of Vehicles.

  15. Privacy-Preserving Authentication Using a Double Pseudonym for Internet of Vehicles

    PubMed Central

    Xu, Wenyu; Zhang, Jing; Xu, Yan; Liu, Lu

    2018-01-01

    The Internet of Vehicles (IoV) plays an important role in smart transportation to reduce the drivers’s risk of having an accident and help them manage small emergencies. Therefore, security and privacy issues of the message in the tamper proof device (TPD) broadcasted to other vehicles and roadside units (RSUs) have become an important research subject in the field of smart transportation. Many authentication schemes are proposed to tackle the challenges above and most of them are heavy in computation and communication. In this paper, we propose a novel authentication scheme that utilizes the double pseudonym method to hide the real identity of vehicles and adopts the dynamic update technology to periodically update the information (such as member secret, authentication key, internal pseudo-identity) stored in the tamper-proof device to prevent the side-channel attack. Because of not using bilinear pairing, our scheme yields a better performance in terms of computation overhead and communication overhead, and is more suitable to be applied in the Internet of Vehicles. PMID:29735941

  16. 29 CFR 1917.46 - Load indicating devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Except as provided in paragraph (a)(1)(viii) of this section, every crane after October 3, 1984 shall be... this by referencing a weight indication to crane ratings posted and visible to the operator, except... the supporting system (crane structure) that its failure could cause the load to be dropped, its...

  17. 29 CFR 1917.46 - Load indicating devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Except as provided in paragraph (a)(1)(viii) of this section, every crane after October 3, 1984 shall be... this by referencing a weight indication to crane ratings posted and visible to the operator, except... the supporting system (crane structure) that its failure could cause the load to be dropped, its...

  18. Unattended wireless proximity sensor networks for counterterrorism, force protection, littoral environments, PHM, and tamper monitoring ground applications

    NASA Astrophysics Data System (ADS)

    Forcier, Bob

    2003-09-01

    This paper describes a digital-ultrasonic ground network, which forms an unique "unattended mote sensor system" for monitoring the environment, personnel, facilities, vehicles, power generation systems or aircraft in Counter-Terrorism, Force Protection, Prognostic Health Monitoring (PHM) and other ground applications. Unattended wireless smart sensor/tags continuously monitor the environment and provide alerts upon changes or disruptions to the environment. These wireless smart sensor/tags are networked utilizing ultrasonic wireless motes, hybrid RF/Ultrasonic Network Nodes and Base Stations. The network is monitored continuously with a 24/7 remote and secure monitoring system. This system utilizes physical objects such as a vehicle"s structure or a building to provide the media for two way secure communication of key metrics and sensor data and eliminates the "blind spots" that are common in RF solutions because of structural elements of buildings, etc. The digital-ultrasonic sensors have networking capability and a 32-bit identifier, which provide a platform for a robust data acquisition (DAQ) for a large amount of sensors. In addition, the network applies a unique "signature" of the environment by comparing sensor-to-sensor data to pick up on minute changes, which would signal an invasion of unknown elements or signal a potential tampering in equipment or facilities. The system accommodates satellite and other secure network uplinks in either RF or UWB protocols. The wireless sensors can be dispersed by ground or air maneuvers. In addition, the sensors can be incorporated into the structure or surfaces of vehicles, buildings, or clothing of field personnel.

  19. Radial Shock Wave Devices Generate Cavitation

    PubMed Central

    Császár, Nikolaus B. M.; Angstman, Nicholas B.; Milz, Stefan; Sprecher, Christoph M.; Kobel, Philippe; Farhat, Mohamed; Furia, John P.; Schmitz, Christoph

    2015-01-01

    Background Conflicting reports in the literature have raised the question whether radial extracorporeal shock wave therapy (rESWT) devices and vibrating massage devices have similar energy signatures and, hence, cause similar bioeffects in treated tissues. Methods and Findings We used laser fiber optic probe hydrophone (FOPH) measurements, high-speed imaging and x-ray film analysis to compare fundamental elements of the energy signatures of two rESWT devices (Swiss DolorClast; Electro Medical Systems, Nyon, Switzerland; D-Actor 200; Storz Medical, Tägerwillen, Switzerland) and a vibrating massage device (Vibracare; G5/General Physiotherapy, Inc., Earth City, MO, USA). To assert potential bioeffects of these treatment modalities we investigated the influence of rESWT and vibrating massage devices on locomotion ability of Caenorhabditis elegans (C. elegans) worms. Results FOPH measurements demonstrated that both rESWT devices generated acoustic waves with comparable pressure and energy flux density. Furthermore, both rESWT devices generated cavitation as evidenced by high-speed imaging and caused mechanical damage on the surface of x-ray film. The vibrating massage device did not show any of these characteristics. Moreover, locomotion ability of C. elegans was statistically significantly impaired after exposure to radial extracorporeal shock waves but was unaffected after exposure of worms to the vibrating massage device. Conclusions The results of the present study indicate that both energy signature and bioeffects of rESWT devices are fundamentally different from those of vibrating massage devices. Clinical Relevance Prior ESWT studies have shown that tissues treated with sufficient quantities of acoustic sound waves undergo cavitation build-up, mechanotransduction, and ultimately, a biological alteration that “kick-starts” the healing response. Due to their different treatment indications and contra-indications rESWT devices cannot be equated to vibrating

  20. Radial Shock Wave Devices Generate Cavitation.

    PubMed

    Császár, Nikolaus B M; Angstman, Nicholas B; Milz, Stefan; Sprecher, Christoph M; Kobel, Philippe; Farhat, Mohamed; Furia, John P; Schmitz, Christoph

    2015-01-01

    Conflicting reports in the literature have raised the question whether radial extracorporeal shock wave therapy (rESWT) devices and vibrating massage devices have similar energy signatures and, hence, cause similar bioeffects in treated tissues. We used laser fiber optic probe hydrophone (FOPH) measurements, high-speed imaging and x-ray film analysis to compare fundamental elements of the energy signatures of two rESWT devices (Swiss DolorClast; Electro Medical Systems, Nyon, Switzerland; D-Actor 200; Storz Medical, Tägerwillen, Switzerland) and a vibrating massage device (Vibracare; G5/General Physiotherapy, Inc., Earth City, MO, USA). To assert potential bioeffects of these treatment modalities we investigated the influence of rESWT and vibrating massage devices on locomotion ability of Caenorhabditis elegans (C. elegans) worms. FOPH measurements demonstrated that both rESWT devices generated acoustic waves with comparable pressure and energy flux density. Furthermore, both rESWT devices generated cavitation as evidenced by high-speed imaging and caused mechanical damage on the surface of x-ray film. The vibrating massage device did not show any of these characteristics. Moreover, locomotion ability of C. elegans was statistically significantly impaired after exposure to radial extracorporeal shock waves but was unaffected after exposure of worms to the vibrating massage device. The results of the present study indicate that both energy signature and bioeffects of rESWT devices are fundamentally different from those of vibrating massage devices. Prior ESWT studies have shown that tissues treated with sufficient quantities of acoustic sound waves undergo cavitation build-up, mechanotransduction, and ultimately, a biological alteration that "kick-starts" the healing response. Due to their different treatment indications and contra-indications rESWT devices cannot be equated to vibrating massage devices and should be used with due caution in clinical practice.

  1. 21 CFR 872.1850 - Lead-lined position indicator.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1850 Lead-lined position indicator. (a... dental x-ray tube and intended to aid in positioning the tube, to prevent the misfocusing of the x-rays...

  2. Imaging with organic indicators and high-speed charge-coupled device cameras in neurons: some applications where these classic techniques have advantages.

    PubMed

    Ross, William N; Miyazaki, Kenichi; Popovic, Marko A; Zecevic, Dejan

    2015-04-01

    Dynamic calcium and voltage imaging is a major tool in modern cellular neuroscience. Since the beginning of their use over 40 years ago, there have been major improvements in indicators, microscopes, imaging systems, and computers. While cutting edge research has trended toward the use of genetically encoded calcium or voltage indicators, two-photon microscopes, and in vivo preparations, it is worth noting that some questions still may be best approached using more classical methodologies and preparations. In this review, we highlight a few examples in neurons where the combination of charge-coupled device (CCD) imaging and classical organic indicators has revealed information that has so far been more informative than results using the more modern systems. These experiments take advantage of the high frame rates, sensitivity, and spatial integration of the best CCD cameras. These cameras can respond to the faster kinetics of organic voltage and calcium indicators, which closely reflect the fast dynamics of the underlying cellular events.

  3. Ventricular assist devices in pediatrics

    PubMed Central

    Fuchs, A; Netz, H

    2001-01-01

    The implantation of a mechanical circulatory device for end-stage ventricular failure is a possible therapeutic approach in adult and pediatric cardiac surgery and cardiology. The aim of this article is to present mechanical circulatory assist devices used in infants and children with special emphasis on extracorporeal membrane oxygenation, Berlin Heart assist device, centrifugal pump and Medos assist device. The success of long-term support with implantable ventricular assist devices in adults and children has led to their increasing use as a bridge to transplantation in patients with otherwise non-treatable left ventricular failure, by transforming a terminal phase heart condition into a treatable cardiopathy. Such therapy allows rehabilitation of patients before elective cardiac transplantation (by removing contraindications to transplantation mainly represented by organ impairment) or acting as a bridge to recovery of the native left ventricular function (depending on underlying cardiac disease). Treatment may also involve permanent device implantation when cardiac transplantation is contraindicated. Indications for the implantation of assisted circulation include all states of cardiac failure that are reversible within a variable period of time or that require heart transplantation. This article will address the current status of ventricular assist devices by examining historical aspects of its development, current technical issues and clinical features of pediatric ventricular assist devices, including indications and contraindications for support. PMID:22368605

  4. Telephone Communication for the Deaf: Speech Indicator Manual.

    ERIC Educational Resources Information Center

    Jones, Ray L.

    The instructional manual is designed to accompany the Speech Indicator, a small, portable, economical ($15) device for deaf persons for telephone communication (available from Leadership Training Program in the Area of the Deaf, San Fernando State College). The device indicates when the other party speaks, not what he says. A topic outline and…

  5. [Supplementary device for a dynamometer to evaluate and register muscular endurance indices].

    PubMed

    Timoshenko, D A; Bokser, O Ia

    1986-01-01

    In practice of psychophysiologic research muscular endurance index is used for estimation of CNS function. Muscular endurance index is defined as relative time needed for maintaining the preset muscular effort. The described device widens the possibilities of a digital dynamometer for automatic estimation and recording of muscular endurance index in real time.

  6. Digital image modification detection using color information and its histograms.

    PubMed

    Zhou, Haoyu; Shen, Yue; Zhu, Xinghui; Liu, Bo; Fu, Zigang; Fan, Na

    2016-09-01

    The rapid development of many open source and commercial image editing software makes the authenticity of the digital images questionable. Copy-move forgery is one of the most widely used tampering techniques to create desirable objects or conceal undesirable objects in a scene. Existing techniques reported in the literature to detect such tampering aim to improve the robustness of these methods against the use of JPEG compression, blurring, noise, or other types of post processing operations. These post processing operations are frequently used with the intention to conceal tampering and reduce tampering clues. A robust method based on the color moments and other five image descriptors is proposed in this paper. The method divides the image into fixed size overlapping blocks. Clustering operation divides entire search space into smaller pieces with similar color distribution. Blocks from the tampered regions will reside within the same cluster since both copied and moved regions have similar color distributions. Five image descriptors are used to extract block features, which makes the method more robust to post processing operations. An ensemble of deep compositional pattern-producing neural networks are trained with these extracted features. Similarity among feature vectors in clusters indicates possible forged regions. Experimental results show that the proposed method can detect copy-move forgery even if an image was distorted by gamma correction, addictive white Gaussian noise, JPEG compression, or blurring. Copyright © 2016. Published by Elsevier Ireland Ltd.

  7. 49 CFR Appendix C to Part 218 - Statement of Agency Enforcement Policy on Tampering

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Act, 49 App. U.S.C. 1801 et seq.) Under that statutory language, the responsible members of the crew... train with a disabled device be operated after having learned that the safety device is not functioning...

  8. Design and Test of an Event Detector for the ReflectoActive Seals System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stinson, Brad J

    2006-05-01

    The purpose of this thesis was to research, design, develop and test a novel instrument for detecting fiber optic loop continuity and spatially locating fiber optic breaches. The work is for an active seal system called ReflectoActive Seals whose purpose is to provide real time container tamper indication. A Field Programmable Gate Array was used to implement a loop continuity detector and a spatial breach locator based on a high acquisition speed single photon counting optical time domain reflectometer. Communication and other control features were added in order to create a usable instrument that met defined requirements. A host graphicalmore » user interface was developed to illustrate system use and performance. The resulting device meets performance specifications by exhibiting a dynamic range of 27dB and a spatial resolution of 1.5 ft. The communication scheme used expands installation options and allows the device to communicate to a central host via existing Local Area Networks and/or the Internet.« less

  9. Design and Test of an Event Detector and Locator for the ReflectoActive Seals System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stinson, Brad J

    2006-06-01

    The purpose of this work was to research, design, develop and test a novel instrument for detecting fiber optic loop continuity and spatially locating fiber optic breaches. The work is for an active seal system called ReflectoActive{trademark} Seals whose purpose is to provide real time container tamper indication. A Field Programmable Gate Array was used to implement a loop continuity detector and a spatial breach locator based on a high acquisition speed single photon counting optical time domain reflectometer. Communication and other control features were added in order to create a usable instrument that met defined requirements. A host graphicalmore » user interface was developed to illustrate system use and performance. The resulting device meets performance specifications by exhibiting a dynamic range of 27dB and a spatial resolution of 1.5 ft. The communication scheme used expands installation options and allows the device to communicate to a central host via existing Local Area Networks and/or the Internet.« less

  10. Wearable Devices in Medical Internet of Things: Scientific Research and Commercially Available Devices

    PubMed Central

    Thurow, Kerstin; Stoll, Regina

    2017-01-01

    Objectives Wearable devices are currently at the heart of just about every discussion related to the Internet of Things. The requirement for self-health monitoring and preventive medicine is increasing due to the projected dramatic increase in the number of elderly people until 2020. Developed technologies are truly able to reduce the overall costs for prevention and monitoring. This is possible by constantly monitoring health indicators in various areas, and in particular, wearable devices are considered to carry this task out. These wearable devices and mobile apps now have been integrated with telemedicine and telehealth efficiently, to structure the medical Internet of Things. This paper reviews wearable health care devices both in scientific papers and commercial efforts. Methods MIoT is demonstrated through a defined architecture design, including hardware and software dealing with wearable devices, sensors, smart phones, medical application, and medical station analyzers for further diagnosis and data storage. Results Wearables, with the help of improved technology have been developed greatly and are considered reliable tools for long-term health monitoring systems. These are applied in the observation of a large variety of health monitoring indicators in the environment, vital signs, and fitness. Conclusions Wearable devices are now used for a wide range of healthcare observation. One of the most important elements essential in data collection is the sensor. During recent years with improvement in semiconductor technology, sensors have made investigation of a full range of parameters closer to realization. PMID:28261526

  11. Wearable Devices in Medical Internet of Things: Scientific Research and Commercially Available Devices.

    PubMed

    Haghi, Mostafa; Thurow, Kerstin; Stoll, Regina

    2017-01-01

    Wearable devices are currently at the heart of just about every discussion related to the Internet of Things. The requirement for self-health monitoring and preventive medicine is increasing due to the projected dramatic increase in the number of elderly people until 2020. Developed technologies are truly able to reduce the overall costs for prevention and monitoring. This is possible by constantly monitoring health indicators in various areas, and in particular, wearable devices are considered to carry this task out. These wearable devices and mobile apps now have been integrated with telemedicine and telehealth efficiently, to structure the medical Internet of Things. This paper reviews wearable health care devices both in scientific papers and commercial efforts. MIoT is demonstrated through a defined architecture design, including hardware and software dealing with wearable devices, sensors, smart phones, medical application, and medical station analyzers for further diagnosis and data storage. Wearables, with the help of improved technology have been developed greatly and are considered reliable tools for long-term health monitoring systems. These are applied in the observation of a large variety of health monitoring indicators in the environment, vital signs, and fitness. Wearable devices are now used for a wide range of healthcare observation. One of the most important elements essential in data collection is the sensor. During recent years with improvement in semiconductor technology, sensors have made investigation of a full range of parameters closer to realization.

  12. Development of a wireless blood pressure measuring device with smart mobile device.

    PubMed

    İlhan, İlhan; Yıldız, İbrahim; Kayrak, Mehmet

    2016-03-01

    Today, smart mobile devices (telephones and tablets) are very commonly used due to their powerful hardware and useful features. According to an eMarketer report, in 2014 there were 1.76 billion smartphone users (excluding users of tablets) in the world; it is predicted that this number will rise by 15.9% to 2.04 billion in 2015. It is thought that these devices can be used successfully in biomedical applications. A wireless blood pressure measuring device used together with a smart mobile device was developed in this study. By means of an interface developed for smart mobile devices with Android and iOS operating systems, a smart mobile device was used both as an indicator and as a control device. The cuff communicating with this device through Bluetooth was designed to measure blood pressure via the arm. A digital filter was used on the cuff instead of the traditional analog signal processing and filtering circuit. The newly developed blood pressure measuring device was tested on 18 patients and 20 healthy individuals of different ages under a physician's supervision. When the test results were compared with the measurements made using a sphygmomanometer, it was shown that an average 93.52% accuracy in sick individuals and 94.53% accuracy in healthy individuals could be achieved with the new device. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. Event-recording devices with identification codes

    NASA Technical Reports Server (NTRS)

    Watters, David G. (Inventor); Huestis, David L. (Inventor); Bahr, Alfred J. (Inventor); Vidmar, Robert J. (Inventor)

    2003-01-01

    A recording device allows wireless interrogation to determine its identity and its state. The state indicates whether one or more physical or chemical events have taken place. In effect, the one or more physical or chemical events are recorded by the device. The identity of the device allows it to be distinguished from a number of similar devices. The recording device may be used in an array of devices that allows wireless probing by an interrogation unit. When probed, each device tells the interrogator who it is and what state it is in. The devices allow multiple use and the interrogator may use a logical reset to determine the state of each device. The interrogator can thus easily identify particular items in an array that have reached a particular condition. The device may record the status of each device in a database to maintain a history for each.

  14. [Development of Audio Indicator System for Respiratory Dynamic CT Imaging].

    PubMed

    Muramatsu, Shun; Moriya, Hiroshi; Tsukagoshi, Shinsuke; Yamada, Norikazu

    We created the device, which can conduct a radiological technologist's voice to a subject during CT scanning. For 149 lung cancer, dynamic respiratory CT were performed. 92 cases were performed using this device, the others were without this device. The respiratory cycle and respiratory amplitude were analyzed from the lung density. A stable respirating cycle was obtained by using the audio indicator system. The audio indicator system is useful for respiratory dynamic CT.

  15. Person-level changes in oxycodone use after the introduction of a tamper-resistant formulation in Australia.

    PubMed

    Schaffer, Andrea L; Buckley, Nicholas A; Degenhardt, Louisa; Larance, Briony; Cairns, Rose; Dobbins, Timothy A; Pearson, Sallie-Anne

    2018-03-26

    Australia introduced tamper-resistant controlled-release (CR) oxycodone in April 2014. We quantified the impact of the reformulation on dispensing, switching and poisonings. We performed interrupted time-series analyses using population-representative national dispensing data from 2012 to 2016. We measured dispensing of oxycodone CR (≥ 10 mg), discontinuation of use of strong opioids and switching to other strong opioids after the reformulation compared with a historical control period. Similarly, we compared calls about intentional opioid poisoning using data from a regional poisons information centre. After the reformulation, dispensing decreased for 10-30 mg (total level shift -11.1%, 95% confidence interval [CI], -17.2% to -4.6%) and 40-80 mg oxycodone CR (total level shift -31.5%, 95% CI -37.5% to -24.9%) in participants less than 65 years of age but was unchanged in people 65 years of age or older. Compared with the previous year, discontinuation of use of strong opioids did not increase (adjusted hazard ratio [HR] 0.95, 95% CI 0.91 to 1.00), but switching to oxycodone/naloxone did increase (adjusted HR 1.54, 95% CI 1.32 to 1.79). Switching to morphine varied by age ( p < 0.001), and the greatest increase was in participants less than 45 years of age (adjusted HR 4.33, 95% CI 2.13 to 8.80). Participants switching after the reformulation were more likely to be dispensed a tablet strength of 40 mg or more (adjusted odds ratio [OR] 1.40, 95% CI 1.09 to 1.79). Calls for intentional poisoning that involved oxycodone taken orally increased immediately after the reformulation (incidence rate ratio (IRR) 1.31, 95% CI 1.05-1.64), but there was no change for injected oxycodone. The reformulation had a greater impact on opioid access patterns of people less than 65 years of age who were using higher strengths of oxycodone CR. This group has been identified as having an increased risk of problematic opioid use and warrants closer monitoring in clinical practice.

  16. Scientific charge-coupled devices

    NASA Technical Reports Server (NTRS)

    Janesick, James R.; Elliott, Tom; Collins, Stewart; Blouke, Morley M.; Freeman, Jack

    1987-01-01

    The charge-coupled device dominates an ever-increasing variety of scientific imaging and spectroscopy applications. Recent experience indicates, however, that the full potential of CCD performance lies well beyond that realized in devices currently available.Test data suggest that major improvements are feasible in spectral response, charge collection, charge transfer, and readout noise. These properties, their measurement in existing CCDs, and their potential for future improvement are discussed in this paper.

  17. 21 CFR 892.5780 - Light beam patient position indicator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Light beam patient position indicator. 892.5780 Section 892.5780 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Therapeutic Devices § 892.5780 Light beam patient position...

  18. 10 CFR 73.70 - Records.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... copy throughout the required retention period. The record may also be stored in electronic media with..., alarm check, and tamper indication that identifies the type of alarm, location, alarm circuit, date, and...

  19. Wireless event-recording device with identification codes

    NASA Technical Reports Server (NTRS)

    Watters, David G. (Inventor); Huestis, David L. (Inventor); Bahr, Alfred J. (Inventor)

    2004-01-01

    A wireless recording device can be interrogated to determine its identity and its state. The state indicates whether a particular physical or chemical event has taken place. In effect, the physical or chemical event is recorded by the device. The identity of the device allows it to be distinguished from a number of similar devices. Thus the sensor device may be used in an array of devices that can be probed by a wireless interrogation unit. The device tells the interrogator who it is and what state it is in. The interrogator can thus easily identify particular items in an array that have reached a particular condition.

  20. A Calibration Method for Nanowire Biosensors to Suppress Device-to-device Variation

    PubMed Central

    Ishikawa, Fumiaki N.; Curreli, Marco; Chang, Hsiao-Kang; Chen, Po-Chiang; Zhang, Rui; Cote, Richard J.; Thompson, Mark E.; Zhou, Chongwu

    2009-01-01

    Nanowire/nanotube biosensors have stimulated significant interest; however the inevitable device-to-device variation in the biosensor performance remains a great challenge. We have developed an analytical method to calibrate nanowire biosensor responses that can suppress the device-to-device variation in sensing response significantly. The method is based on our discovery of a strong correlation between the biosensor gate dependence (dIds/dVg) and the absolute response (absolute change in current, ΔI). In2O3 nanowire based biosensors for streptavidin detection were used as the model system. Studying the liquid gate effect and ionic concentration dependence of strepavidin sensing indicates that electrostatic interaction is the dominant mechanism for sensing response. Based on this sensing mechanism and transistor physics, a linear correlation between the absolute sensor response (ΔI) and the gate dependence (dIds/dVg) is predicted and confirmed experimentally. Using this correlation, a calibration method was developed where the absolute response is divided by dIds/dVg for each device, and the calibrated responses from different devices behaved almost identically. Compared to the common normalization method (normalization of the conductance/resistance/current by the initial value), this calibration method was proved advantageous using a conventional transistor model. The method presented here substantially suppresses device-to-device variation, allowing the use of nanosensors in large arrays. PMID:19921812

  1. 33 CFR 159.83 - Level indicator.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Level indicator. 159.83 Section 159.83 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.83 Level indicator. Each sewage...

  2. 33 CFR 159.83 - Level indicator.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Level indicator. 159.83 Section 159.83 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.83 Level indicator. Each sewage...

  3. 33 CFR 159.65 - Chemical level indicator.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Chemical level indicator. 159.65...) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.65 Chemical level indicator. The... any chemical that is necessary for its effective operation. (b) A means of indicating when chemicals...

  4. 33 CFR 159.65 - Chemical level indicator.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Chemical level indicator. 159.65...) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.65 Chemical level indicator. The... any chemical that is necessary for its effective operation. (b) A means of indicating when chemicals...

  5. 33 CFR 159.65 - Chemical level indicator.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Chemical level indicator. 159.65...) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.65 Chemical level indicator. The... any chemical that is necessary for its effective operation. (b) A means of indicating when chemicals...

  6. 33 CFR 159.65 - Chemical level indicator.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Chemical level indicator. 159.65...) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.65 Chemical level indicator. The... any chemical that is necessary for its effective operation. (b) A means of indicating when chemicals...

  7. 33 CFR 159.65 - Chemical level indicator.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Chemical level indicator. 159.65...) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.65 Chemical level indicator. The... any chemical that is necessary for its effective operation. (b) A means of indicating when chemicals...

  8. 49 CFR 236.23 - Aspects and indications.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.23 Aspects and indications. (a) Aspects shall be... with any other name and indication. (d) The fundamental indications of signal aspects shall conform to...

  9. Design, fabrication, and delivery of a charge injection device as a stellar tracking device

    NASA Technical Reports Server (NTRS)

    Burke, H. K.; Michon, G. J.; Tomlinson, H. W.; Vogelsong, T. L.; Grafinger, A.; Wilson, R.

    1979-01-01

    Six 128 x 128 CID imagers fabricated on bulk silicon and with thin polysilicon upper-level electrodes were tested in a star tracking mode. Noise and spectral response were measured as a function of temperature over the range of +25 C to -40 C. Noise at 0 C and below was less than 40 rms carriers/pixel for all devices at an effective noise bandwidth of 150 Hz. Quantum yield for all devices averaged 40% from 0.4 to 1.0 microns with no measurable temperature dependence. Extrapolating from these performance parameters to those of a large (400 x 400) array and accounting for design and processing improvements, indicates that the larger array would show a further improvement in noise performance -- on the order of 25 carriers. A preliminary evaluation of the projected performance of the 400 x 400 array and a representative set of star sensor requirements indicates that the CID has excellent potential as a stellar tracking device.

  10. Security inspection in ports by anomaly detection using hyperspectral imaging technology

    NASA Astrophysics Data System (ADS)

    Rivera, Javier; Valverde, Fernando; Saldaña, Manuel; Manian, Vidya

    2013-05-01

    Applying hyperspectral imaging technology in port security is crucial for the detection of possible threats or illegal activities. One of the most common problems that cargo suffers is tampering. This represents a danger to society because it creates a channel to smuggle illegal and hazardous products. If a cargo is altered, security inspections on that cargo should contain anomalies that reveal the nature of the tampering. Hyperspectral images can detect anomalies by gathering information through multiple electromagnetic bands. The spectrums extracted from these bands can be used to detect surface anomalies from different materials. Based on this technology, a scenario was built in which a hyperspectral camera was used to inspect the cargo for any surface anomalies and a user interface shows the results. The spectrum of items, altered by different materials that can be used to conceal illegal products, is analyzed and classified in order to provide information about the tampered cargo. The image is analyzed with a variety of techniques such as multiple features extracting algorithms, autonomous anomaly detection, and target spectrum detection. The results will be exported to a workstation or mobile device in order to show them in an easy -to-use interface. This process could enhance the current capabilities of security systems that are already implemented, providing a more complete approach to detect threats and illegal cargo.

  11. 49 CFR 174.9 - Safety and security inspection and acceptance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... of this subchapter, rail carload quantities of ammonium nitrate or ammonium nitrate mixtures in solid... accordance with § 174.50. (d) Where an indication of tampering or suspicious item is found, a carrier must...

  12. Material selection indices for design of surgical instruments with long tubular shafts.

    PubMed

    Nelson, Carl A

    2013-02-01

    In any medical device design process, material selection plays an important role. For devices which sustain mechanical loading, strength and stiffness requirements can be significant drivers of the design. This paper examines the specific case of minimally invasive surgical instruments, including robotic instruments, having long, tubular shafts. Material properties-based selection indices are derived for achieving high performance of these devices in terms of strength and stiffness, and the use of these indices for informing the medical device design problem is illustrated.

  13. Atherectomy devices: technology update

    PubMed Central

    Akkus, Nuri I; Abdulbaki, Abdulrahman; Jimenez, Enrique; Tandon, Neeraj

    2015-01-01

    Atherectomy is a procedure which is performed to remove atherosclerotic plaque from diseased arteries. Atherosclerotic plaques are localized in either coronary or peripheral arterial vasculature and may have different characteristics depending on the texture of the plaque. Atherectomy has been used effectively in treatment of both coronary and peripheral arterial disease. Atherectomy devices are designed differently to either cut, shave, sand, or vaporize these plaques and have different indications. In this article, current atherectomy devices are reviewed. PMID:25565904

  14. Triboluminescent indicator system

    DOEpatents

    Goods, Steven H.; Dentinger, Paul M.; Whinnery, Jr., Leroy L.

    2003-06-24

    There is provided a light emitting device comprising a plurality of triboluminescent particles dispersed throughout a low density, frangible body and activated by rapidly crushing the body in order to transfer mechanical energy to some portion of the particles. The light emitted by these mechanically excited particles is collected and directed into a light conduit and transmitted to a detector/indicator means.

  15. Automatic Mechetronic Wheel Light Device

    DOEpatents

    Khan, Mohammed John Fitzgerald

    2004-09-14

    A wheel lighting device for illuminating a wheel of a vehicle to increase safety and enhance aesthetics. The device produces the appearance of a "ring of light" on a vehicle's wheels as the vehicle moves. The "ring of light" can automatically change in color and/or brightness according to a vehicle's speed, acceleration, jerk, selection of transmission gears, and/or engine speed. The device provides auxiliary indicator lights by producing light in conjunction with a vehicle's turn signals, hazard lights, alarm systems, and etc. The device comprises a combination of mechanical and electronic components and can be placed on the outer or inner surface of a wheel or made integral to a wheel or wheel cover. The device can be configured for all vehicle types, and is electrically powered by a vehicle's electrical system and/or battery.

  16. 47 CFR 80.927 - Antenna radio frequency indicator.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Antenna radio frequency indicator. 80.927... Boats § 80.927 Antenna radio frequency indicator. The transmitter must be equipped with a device which provides visual indication whenever the transmitter is supplying power to the antenna. ...

  17. 47 CFR 80.927 - Antenna radio frequency indicator.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Antenna radio frequency indicator. 80.927... Boats § 80.927 Antenna radio frequency indicator. The transmitter must be equipped with a device which provides visual indication whenever the transmitter is supplying power to the antenna. ...

  18. 47 CFR 80.927 - Antenna radio frequency indicator.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Antenna radio frequency indicator. 80.927... Boats § 80.927 Antenna radio frequency indicator. The transmitter must be equipped with a device which provides visual indication whenever the transmitter is supplying power to the antenna. ...

  19. 47 CFR 80.927 - Antenna radio frequency indicator.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Antenna radio frequency indicator. 80.927... Boats § 80.927 Antenna radio frequency indicator. The transmitter must be equipped with a device which provides visual indication whenever the transmitter is supplying power to the antenna. ...

  20. 47 CFR 80.927 - Antenna radio frequency indicator.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Antenna radio frequency indicator. 80.927... Boats § 80.927 Antenna radio frequency indicator. The transmitter must be equipped with a device which provides visual indication whenever the transmitter is supplying power to the antenna. ...

  1. Mobile Device Security: Perspectives of Future Healthcare Workers

    PubMed Central

    Hewitt, Barbara; Dolezel, Diane; McLeod, Alexander

    2017-01-01

    Healthcare data breaches on mobile devices continue to increase, yet the healthcare industry has not adopted mobile device security standards. This increase is disturbing because individuals are often accessing patients’ protected health information on personal mobile devices, which could lead to a data breach. This deficiency led the researchers to explore the perceptions of future healthcare workers regarding mobile device security. To determine healthcare students’ perspectives on mobile device security, the investigators designed and distributed a survey based on the Technology Threat Avoidance Theory. Three hundred thirty-five students participated in the survey. The data were analyzed to determine participants’ perceptions about security threats, effectiveness and costs of safeguards, self-efficacy, susceptibility, severity, and their motivation and actions to secure their mobile devices. Awareness of interventions to protect mobile devices was also examined. Results indicate that while future healthcare professionals perceive the severity of threats to their mobile data, they do not feel personally susceptible. Additionally, participants were knowledgeable about security safeguards, but their knowledge of costs and problems related to the adoption of these measures was mixed. These findings indicate that increasing security awareness of healthcare professionals should be a priority. PMID:28566992

  2. Mobile Device Security: Perspectives of Future Healthcare Workers.

    PubMed

    Hewitt, Barbara; Dolezel, Diane; McLeod, Alexander

    2017-01-01

    Healthcare data breaches on mobile devices continue to increase, yet the healthcare industry has not adopted mobile device security standards. This increase is disturbing because individuals are often accessing patients' protected health information on personal mobile devices, which could lead to a data breach. This deficiency led the researchers to explore the perceptions of future healthcare workers regarding mobile device security. To determine healthcare students' perspectives on mobile device security, the investigators designed and distributed a survey based on the Technology Threat Avoidance Theory. Three hundred thirty-five students participated in the survey. The data were analyzed to determine participants' perceptions about security threats, effectiveness and costs of safeguards, self-efficacy, susceptibility, severity, and their motivation and actions to secure their mobile devices. Awareness of interventions to protect mobile devices was also examined. Results indicate that while future healthcare professionals perceive the severity of threats to their mobile data, they do not feel personally susceptible. Additionally, participants were knowledgeable about security safeguards, but their knowledge of costs and problems related to the adoption of these measures was mixed. These findings indicate that increasing security awareness of healthcare professionals should be a priority.

  3. Electrical and electronic devices and components: A compilation

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Components and techniques which may be useful in the electronics industry are described. Topics discussed include transducer technology, printed-circuit technology, solid state devices, MOS transistors, Gunn device, microwave antennas, and position indicators.

  4. Studies and research concerning BNFP: process monitoring and process surveillance demonstration program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kight, H R

    1979-11-01

    Computerized methods of monitoring process functions and alarming off-standard conditions were implemented and demonstrated during the FY 1979 Uranium Run. In addition, prototype applications of instruments for the purpose of tamper indication and surveillance were tested.

  5. Person-level changes in oxycodone use after the introduction of a tamper-resistant formulation in Australia

    PubMed Central

    Buckley, Nicholas A.; Degenhardt, Louisa; Larance, Briony; Cairns, Rose; Dobbins, Timothy A.; Pearson, Sallie-Anne

    2018-01-01

    BACKGROUND: Australia introduced tamper-resistant controlled-release (CR) oxycodone in April 2014. We quantified the impact of the reformulation on dispensing, switching and poisonings. METHODS: We performed interrupted time-series analyses using population-representative national dispensing data from 2012 to 2016. We measured dispensing of oxycodone CR (≥ 10 mg), discontinuation of use of strong opioids and switching to other strong opioids after the reformulation compared with a historical control period. Similarly, we compared calls about intentional opioid poisoning using data from a regional poisons information centre. RESULTS: After the reformulation, dispensing decreased for 10–30 mg (total level shift −11.1%, 95% confidence interval [CI], −17.2% to −4.6%) and 40–80 mg oxycodone CR (total level shift −31.5%, 95% CI −37.5% to −24.9%) in participants less than 65 years of age but was unchanged in people 65 years of age or older. Compared with the previous year, discontinuation of use of strong opioids did not increase (adjusted hazard ratio [HR] 0.95, 95% CI 0.91 to 1.00), but switching to oxycodone/naloxone did increase (adjusted HR 1.54, 95% CI 1.32 to 1.79). Switching to morphine varied by age (p < 0.001), and the greatest increase was in participants less than 45 years of age (adjusted HR 4.33, 95% CI 2.13 to 8.80). Participants switching after the reformulation were more likely to be dispensed a tablet strength of 40 mg or more (adjusted odds ratio [OR] 1.40, 95% CI 1.09 to 1.79). Calls for intentional poisoning that involved oxycodone taken orally increased immediately after the reformulation (incidence rate ratio (IRR) 1.31, 95% CI 1.05–1.64), but there was no change for injected oxycodone. INTERPRETATION: The reformulation had a greater impact on opioid access patterns of people less than 65 years of age who were using higher strengths of oxycodone CR. This group has been identified as having an increased risk of problematic opioid

  6. Basic Research of Intrinsic Tamper Indication Markings Defined by Pulsed Laser Irradiation (Quad Chart).

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moody, Neville R.

    Objective: We will research how short (ns) and ultrashort (fs) laser pulses interact with the surfaces of various materials to create complex color layers and morphological patterns. Method: We are investigating the site-specific, formation of microcolor features. Also, research includes a fundamental study of the physics underlying periodic ripple formation during femtosecond laser irradiation. Status of effort: Laser induced color markings were demonstrated on an increased number of materials (including metal thin films) and investigated for optical properties and microstructure. Technology that allows for marking curved surfaces (and large areas) has been implemented. We have used electro-magnetic solvers to modelmore » light-solid interactions leading to periodic surface ripple patterns. This includes identifying the roles of surface plasmon polaritons. Goals/Milestones: Research corrosion resistance of oxide color markings (salt spray, fog, polarization tests); Through modeling, investigate effects of multi-source scattering and interference on ripple patterns; Investigate microspectrophotometry for mapping color; and Investigate new methods for laser color marking curved surfaces and large areas.« less

  7. Position indicator

    DOEpatents

    Tanner, David E.

    1981-01-01

    A nuclear reactor system is described in which a position indicator is provided for detecting and indicating the position of a movable element inside a pressure vessel. The movable element may be a valve element or similar device which moves about an axis. Light from a light source is transmitted from a source outside the pressure vessel to a first region inside the pressure vessel in alignment with the axis of the movable element. The light is redirected by a reflector prism to a second region displaced radially from the first region. The reflector prism moves in response to movement of the movable element about its axis such that the second region moves arcuately with respect to the first region. Sensors are arrayed in an arc corresponding to the arc of movement of the second region and signals are transmitted from the sensors to the exterior of the reactor vessel to provide indication of the position of the movable element.

  8. Precision alignment device

    DOEpatents

    Jones, Nelson E.

    1990-01-01

    Apparatus for providing automatic alignment of beam devices having an associated structure for directing, collimating, focusing, reflecting, or otherwise modifying the main beam. A reference laser is attached to the structure enclosing the main beam producing apparatus and produces a reference beam substantially parallel to the main beam. Detector modules containing optical switching devices and optical detectors are positioned in the path of the reference beam and are effective to produce an electrical output indicative of the alignment of the main beam. This electrical output drives servomotor operated adjustment screws to adjust the position of elements of the structure associated with the main beam to maintain alignment of the main beam.

  9. Accessing global data from accelerator devices

    DOEpatents

    Bertolli, Carlo; O'Brien, John K.; Sallenave, Olivier H.; Sura, Zehra N.

    2016-12-06

    An aspect includes a table of contents (TOC) that was generated by a compiler being received at an accelerator device. The TOC includes an address of global data in a host memory space. The global data is copied from the address in the host memory space to an address in the device memory space. The address in the host memory space is obtained from the received TOC. The received TOC is updated to indicate that global data is stored at the address in the device memory space. A kernel that accesses the global data from the address in the device memory space is executed. The address in the device memory space is obtained based on contents of the updated TOC. When the executing is completed, the global data from the address in the device memory space is copied to the address in the host memory space.

  10. Evaluating Device Design and Cleanability of Orthopedic Device Models Contaminated with a Clinically Relevant Bone Test Soil.

    PubMed

    Lucas, Anne D; Nagaraja, Srinidhi; Gordon, Edward A; Hitchins, Victoria M

    2015-01-01

    Reusable medical devices need to be cleaned prior to disinfection or sterilization and subsequent use to prevent infections. The cleanability of medical devices depends in part on the design of the device. This study examined how models of orthopedic medical devices of increasing complexity retain calcium phosphate bone cement, a relevant test soil for these devices. The dye Alizarin Red S and micro-computed tomography (μCT) were used to assess the amount and location of bone cement debris in a series of model orthopedic devices. Testing was performed after soiling and cleaning once, and soiling and cleaning 10 times. The color change of the dye after reacting with the bone cement was useful for indicating the presence of bone cement in these models. High-resolution μCT analysis provided the volume and location of the bone cement. Models that were more complex retained significantly more bone debris than simpler designs. Model devices repeatedly soiled and cleaned 10 times retained significantly more bone debris than those soiled and cleaned once. Significantly more bone cement was retained in the more complex lumen structures. This information may be useful in designing reusable orthopedic devices, and other complex medical devices with lumens.

  11. System and Method for Detecting Unauthorized Device Access by Comparing Multiple Independent Spatial-Time Data Sets from Other Devices

    NASA Technical Reports Server (NTRS)

    Westmeyer, Paul A. (Inventor); Wertenberg, Russell F. (Inventor); Krage, Frederick J. (Inventor); Riegel, Jack F. (Inventor)

    2017-01-01

    An authentication procedure utilizes multiple independent sources of data to determine whether usage of a device, such as a desktop computer, is authorized. When a comparison indicates an anomaly from the base-line usage data, the system, provides a notice that access of the first device is not authorized.

  12. RADIO RANGING DEVICE

    DOEpatents

    Bogle, R.W.

    1960-11-22

    A description is given of a super-regenerative oscillator ranging device provided with radiating and receiving means and being capable of indicating the occurrence of that distance between itself and a reflecting object which so phases the received echo of energy of a preceding emitted oscillation that the intervals between oscillations become uniform.

  13. [Importance of mechanical assist devices in acute circulatory arrest].

    PubMed

    Ferrari, Markus Wolfgang

    2016-03-01

    Mechanical assist devices are indicated for hemodynamic stabilization in acute circulatory arrest if conventional means of cardiopulmonary resuscitation are unable to re-establish adequate organ perfusion. Their temporary use facilitates further diagnostic and therapeutic options in selected patients, e.g. coronary angiography followed by revascularization.External thorax compression devices allow sufficient cardiac massage in case of preclinical or in-hospital circulatory arrest, especially under complex transfer conditions. These devices perform standardized thorax compressions at a rate of 80-100 per minute. Invasive mechanical support devices are used in the catheter laboratory or in the intensive care unit. Axial turbine pumps, e.g. the Impella, continuously pump blood from the left ventricle into the aortic root. The Impella can also provide right ventricle support by pumping blood from the vena cava into the pulmonary artery. So-called emergency systems or ECMO devices consist of a centrifugal pump and a membrane oxygenator allowing complete takeover of cardiac and pulmonary functions. Withdrawing blood from the right atrium and vena cava, oxygenated blood is returned to the abdominal aorta. Isolated centrifugal pumps provide left heart support without an oxygenator after transseptal insertion of a venous cannula into the left atrium.Mechanical assist devices are indicated for acute organ protection and hemodynamic stabilization for diagnostic and therapeutic measures as well as bridge to myocardial recovery. Future technical developments and better insights into the pathophysiology of mechanical circulatory support will broaden the spectrum of indications of such devices in acute circulatory arrest.

  14. Single-Event Effects in Silicon Carbide Power Devices

    NASA Technical Reports Server (NTRS)

    Lauenstein, Jean-Marie; Casey, Megan C.; LaBel, Kenneth A.; Ikpe, Stanley; Topper, Alyson D.; Wilcox, Edward P.; Kim, Hak; Phan, Anthony M.

    2015-01-01

    This report summarizes the NASA Electronic Parts and Packaging Program Silicon Carbide Power Device Subtask efforts in FY15. Benefits of SiC are described and example NASA Programs and Projects desiring this technology are given. The current status of the radiation tolerance of silicon carbide power devices is given and paths forward in the effort to develop heavy-ion single-event effect hardened devices indicated.

  15. 49 CFR 178.338-14 - Gauging devices.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... gauging devices, which accurately indicate the maximum permitted liquid level at the loading pressure, in... trycock line, or a differential pressure liquid level gauge must be used as the primary control for... filling. (2) The design pressure of each liquid level gauging device must be at least that of the tank. (3...

  16. 49 CFR 178.338-14 - Gauging devices.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... gauging devices, which accurately indicate the maximum permitted liquid level at the loading pressure, in... trycock line, or a differential pressure liquid level gauge must be used as the primary control for... filling. (2) The design pressure of each liquid level gauging device must be at least that of the tank. (3...

  17. 49 CFR 178.338-14 - Gauging devices.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... gauging devices, which accurately indicate the maximum permitted liquid level at the loading pressure, in... trycock line, or a differential pressure liquid level gauge must be used as the primary control for... filling. (2) The design pressure of each liquid level gauging device must be at least that of the tank. (3...

  18. 49 CFR 178.338-14 - Gauging devices.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... gauging devices, which accurately indicate the maximum permitted liquid level at the loading pressure, in... trycock line, or a differential pressure liquid level gauge must be used as the primary control for... filling. (2) The design pressure of each liquid level gauging device must be at least that of the tank. (3...

  19. Precision alignment device

    DOEpatents

    Jones, N.E.

    1988-03-10

    Apparatus for providing automatic alignment of beam devices having an associated structure for directing, collimating, focusing, reflecting, or otherwise modifying the main beam. A reference laser is attached to the structure enclosing the main beam producing apparatus and produces a reference beam substantially parallel to the main beam. Detector modules containing optical switching devices and optical detectors are positioned in the path of the reference beam and are effective to produce an electrical output indicative of the alignment of the main beam. This electrical output drives servomotor operated adjustment screws to adjust the position of elements of the structure associated with the main beam to maintain alignment of the main beam. 5 figs.

  20. System Control Applications of Low-Power Radio Frequency Devices

    NASA Astrophysics Data System (ADS)

    van Rensburg, Roger

    2017-09-01

    This paper conceptualizes a low-power wireless sensor network design for application employment to reduce theft of portable computer devices used in educational institutions today. The aim of this study is to design and develop a reliable and robust wireless network that can eradicate accessibility of a device’s human interface. An embedded system supplied by an energy harvesting source, installed on the portable computer device, may represent one of multiple slave nodes which request regular updates from a standalone master station. A portable computer device which is operated in an undesignated area or in a field perimeter where master to slave communication is restricted, indicating a possible theft scenario, will initiate a shutdown of its operating system and render the device unusable. Consequently, an algorithm in the device firmware may ensure the necessary steps are executed to track the device, irrespective whether the device is enabled. Design outcomes thus far indicate that a wireless network using low-power embedded hardware, is feasible for anti-theft applications. By incorporating one of the latest Bluetooth low-energy, ANT+, ZigBee or Thread wireless technologies, an anti-theft system may be implemented that has the potential to reduce major portable computer device theft in institutions of digitized learning.

  1. Inferior Vena Cava Filters: Guidelines, Best Practice, and Expanding Indications

    PubMed Central

    DeYoung, Elliot; Minocha, Jeet

    2016-01-01

    Vena caval interruption, currently accomplished by percutaneous image-guided insertion of an inferior vena cava (IVC) filter, is an important therapeutic option in the management of selected patients with venous thromboembolism. The availability of optional (or retrievable) filters, in particular, has altered the practice patterns for IVC filters, with a shift to these devices and expansion of indications for filter placement. As new devices have become available and clinicians have become more familiar and comfortable with IVC filters, the indications for filter placement have continued to evolve and expand. This article reviews current guidelines and expanding indications for IVC filter placement. PMID:27247472

  2. Accessing global data from accelerator devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bertolli, Carlo; O'Brien, John K.; Sallenave, Olivier H.

    2016-12-06

    An aspect includes a table of contents (TOC) that was generated by a compiler being received at an accelerator device. The TOC includes an address of global data in a host memory space. The global data is copied from the address in the host memory space to an address in the device memory space. The address in the host memory space is obtained from the received TOC. The received TOC is updated to indicate that global data is stored at the address in the device memory space. A kernel that accesses the global data from the address in the devicemore » memory space is executed. The address in the device memory space is obtained based on contents of the updated TOC. When the executing is completed, the global data from the address in the device memory space is copied to the address in the host memory space.« less

  3. Percutaneous Ventricular Assist Devices: New Deus Ex Machina?

    PubMed Central

    Arroyo, Diego; Cook, Stéphane

    2011-01-01

    The development of ventricular assist devices has broadened the means with which one can treat acute heart failure. Percutaneous ventricular assist devices (pVAD) have risen from recent technological advances. They are smaller, easier, and faster to implant, all important qualities in the setting of acute heart failure. The present paper briefly describes the functioning and assets of the most common devices used today. It gives an overview of the current evidence and indications for left ventricular assist device use in cardiogenic shock and high-risk percutaneous coronary intervention. Finally, extracorporeal life support devices are dealt with in the setting of hemodynamic support. PMID:22091361

  4. A source-channel coding approach to digital image protection and self-recovery.

    PubMed

    Sarreshtedari, Saeed; Akhaee, Mohammad Ali

    2015-07-01

    Watermarking algorithms have been widely applied to the field of image forensics recently. One of these very forensic applications is the protection of images against tampering. For this purpose, we need to design a watermarking algorithm fulfilling two purposes in case of image tampering: 1) detecting the tampered area of the received image and 2) recovering the lost information in the tampered zones. State-of-the-art techniques accomplish these tasks using watermarks consisting of check bits and reference bits. Check bits are used for tampering detection, whereas reference bits carry information about the whole image. The problem of recovering the lost reference bits still stands. This paper is aimed at showing that having the tampering location known, image tampering can be modeled and dealt with as an erasure error. Therefore, an appropriate design of channel code can protect the reference bits against tampering. In the present proposed method, the total watermark bit-budget is dedicated to three groups: 1) source encoder output bits; 2) channel code parity bits; and 3) check bits. In watermark embedding phase, the original image is source coded and the output bit stream is protected using appropriate channel encoder. For image recovery, erasure locations detected by check bits help channel erasure decoder to retrieve the original source encoded image. Experimental results show that our proposed scheme significantly outperforms recent techniques in terms of image quality for both watermarked and recovered image. The watermarked image quality gain is achieved through spending less bit-budget on watermark, while image recovery quality is considerably improved as a consequence of consistent performance of designed source and channel codes.

  5. 10 CFR 73.51 - Requirements for the physical protection of stored spent nuclear fuel and high-level radioactive...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... security organization must include sufficient personnel per shift to provide for monitoring of detection... authorization and visually searched for explosives before entry. (10) Written response procedures must be... termination of the license. (11) All detection systems and supporting subsystems must be tamper indicating...

  6. 10 CFR 73.51 - Requirements for the physical protection of stored spent nuclear fuel and high-level radioactive...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... security organization must include sufficient personnel per shift to provide for monitoring of detection... authorization and visually searched for explosives before entry. (10) Written response procedures must be... termination of the license. (11) All detection systems and supporting subsystems must be tamper indicating...

  7. 10 CFR 73.51 - Requirements for the physical protection of stored spent nuclear fuel and high-level radioactive...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... security organization must include sufficient personnel per shift to provide for monitoring of detection... authorization and visually searched for explosives before entry. (10) Written response procedures must be... termination of the license. (11) All detection systems and supporting subsystems must be tamper indicating...

  8. 10 CFR 73.51 - Requirements for the physical protection of stored spent nuclear fuel and high-level radioactive...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... security organization must include sufficient personnel per shift to provide for monitoring of detection... authorization and visually searched for explosives before entry. (10) Written response procedures must be... termination of the license. (11) All detection systems and supporting subsystems must be tamper indicating...

  9. Description of Ophthalmic Pharmaceutical and Device Start-Up Companies.

    PubMed

    Sharpe, R Allan; Austin, Jennifer P; Kruft, Bonnie; Nelson, Lindsay A; Stewart, Jeanette A; Stewart, William C

    2015-01-01

    To describe the number, type and location of ophthalmic companies and their associated product areas and indications. A retrospective, non-patient-based, observational review of ophthalmic pharmaceutical and device companies with a new product in development. Data was compiled by Internet searches. We identified 190 companies currently developing ophthalmic products: 134 (71%) were privately held and 56 (29%) publicly held, while 136 (72%) were in the United States and 53 (28%) were outside the United States. There were 436 total products of which 338 (78%) were pharmaceuticals and 98 (22%) devices. With pharmaceuticals we identified 46 separate indications with age-related macular degeneration (n = 75), glaucoma (n = 52) and dry eye (n = 46) as most common; anti-vascular endothelial growth factor, hormone therapy and anti-inflammatory products were also common classes. With devices there were 30 indications with glaucoma (n = 26), age-related macular degeneration (n = 19) and dry eye (n = 6) as most common; drug delivery, ocular implants and prostheses were less common classes. Ophthalmology as a specialty is benefited by a wide effort in new medicine and device development. However, a concentration of effort into relatively few indications suggests a potential lack of market analysis and possible difficulty for many companies in commercializing their product. © 2015 S. Karger AG, Basel.

  10. Swell Sleeves for Testing Explosive Devices

    NASA Technical Reports Server (NTRS)

    Hinkel, Todd J.; Dean, Richard J.; Hohmann, Carl W.; Hacker, Scott C.; Harrington, Douglas W.; Bacak, James W.

    2003-01-01

    A method of testing explosive and pyrotechnic devices involves exploding the devices inside swell sleeves. Swell sleeves have been used previously for measuring forces. In the present method, they are used to obtain quantitative indications of the energy released in explosions of the devices under test. A swell sleeve is basically a thick-walled, hollow metal cylinder threaded at one end to accept a threaded surface on a device to be tested (see Figure 1). Once the device has been tightly threaded in place in the swell sleeve, the device-and-swell-sleeve assembly is placed in a test fixture, then the device is detonated. After the explosion, the assembly is removed from the test fixture and placed in a coordinate-measuring machine for measurement of the diameter of the swell sleeve as a function of axial position. For each axial position, the original diameter of the sleeve is subtracted from the diameter of the sleeve as swollen by the explosion to obtain the diametral swelling as a function of axial position (see Figure 2). The amount of swelling is taken as a measure of the energy released in the explosion. The amount of swelling can be compared to a standard amount of swelling to determine whether the pyrotechnic device functioned as specified.

  11. Aircraft control position indicator

    NASA Technical Reports Server (NTRS)

    Dennis, Dale V. (Inventor)

    1987-01-01

    An aircraft control position indicator was provided that displayed the degree of deflection of the primary flight control surfaces and the manner in which the aircraft responded. The display included a vertical elevator dot/bar graph meter display for indication whether the aircraft will pitch up or down, a horizontal aileron dot/bar graph meter display for indicating whether the aircraft will roll to the left or to the right, and a horizontal dot/bar graph meter display for indicating whether the aircraft will turn left or right. The vertical and horizontal display or displays intersect to form an up/down, left/right type display. Internal electronic display driver means received signals from transducers measuring the control surface deflections and determined the position of the meter indicators on each dot/bar graph meter display. The device allows readability at a glance, easy visual perception in sunlight or shade, near-zero lag in displaying flight control position, and is not affected by gravitational or centrifugal forces.

  12. 21 CFR 807.65 - Exemptions for device establishments.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., who manufacture or otherwise alter devices solely for use in their practice. (e) Pharmacies, surgical.... This exemption also applies to a pharmacy or other similar retail establishment that purchases a device... bandage or crutch, indicating “distributed by” or “manufactured for” followed by the name of the pharmacy...

  13. 21 CFR 807.65 - Exemptions for device establishments.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., who manufacture or otherwise alter devices solely for use in their practice. (e) Pharmacies, surgical.... This exemption also applies to a pharmacy or other similar retail establishment that purchases a device... bandage or crutch, indicating “distributed by” or “manufactured for” followed by the name of the pharmacy...

  14. 21 CFR 807.65 - Exemptions for device establishments.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., who manufacture or otherwise alter devices solely for use in their practice. (e) Pharmacies, surgical.... This exemption also applies to a pharmacy or other similar retail establishment that purchases a device... bandage or crutch, indicating “distributed by” or “manufactured for” followed by the name of the pharmacy...

  15. 21 CFR 807.65 - Exemptions for device establishments.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., who manufacture or otherwise alter devices solely for use in their practice. (e) Pharmacies, surgical.... This exemption also applies to a pharmacy or other similar retail establishment that purchases a device... bandage or crutch, indicating “distributed by” or “manufactured for” followed by the name of the pharmacy...

  16. 21 CFR 807.65 - Exemptions for device establishments.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., who manufacture or otherwise alter devices solely for use in their practice. (e) Pharmacies, surgical.... This exemption also applies to a pharmacy or other similar retail establishment that purchases a device... bandage or crutch, indicating “distributed by” or “manufactured for” followed by the name of the pharmacy...

  17. Miniature ingestible telemeter devices to measure deep-body temperature

    NASA Technical Reports Server (NTRS)

    Pope, J. M.; Fryer, T. B. (Inventor)

    1976-01-01

    A telemetry device comprised of a pill-size ingestible transmitter developed to obtain deep body temperature measurements of a human is described. The device has particular utility in the medical field where deep body temperatures provide an indication of general health.

  18. Physician-industry cooperation in the medical device industry.

    PubMed

    Chatterji, Aaron K; Fabrizio, Kira R; Mitchell, Will; Schulman, Kevin A

    2008-01-01

    Anecdotal evidence suggests that innovative medical devices often arise from physicians' inventive activity, but no studies have documented the extent of such physician-engaged innovation. This paper uses patent data and the American Medical Association Physician Masterfile to provide evidence that physicians contribute to medical device innovation, accounting for almost 20 percent of approximately 26,000 medical device patents filed in the United States during 1990-1996. Moreover, two measures indicate that physician patents had more influence on subsequent inventive activity than nonphysician patents. This finding supports the maintenance of an open environment for physician-industry collaboration in the medical device discovery process.

  19. An Enhanced Secure Identity-Based Certificateless Public Key Authentication Scheme for Vehicular Sensor Networks

    PubMed Central

    Li, Congcong; Zhang, Xi; Wang, Haiping; Li, Dongfeng

    2018-01-01

    Vehicular sensor networks have been widely applied in intelligent traffic systems in recent years. Because of the specificity of vehicular sensor networks, they require an enhanced, secure and efficient authentication scheme. Existing authentication protocols are vulnerable to some problems, such as a high computational overhead with certificate distribution and revocation, strong reliance on tamper-proof devices, limited scalability when building many secure channels, and an inability to detect hardware tampering attacks. In this paper, an improved authentication scheme using certificateless public key cryptography is proposed to address these problems. A security analysis of our scheme shows that our protocol provides an enhanced secure anonymous authentication, which is resilient against major security threats. Furthermore, the proposed scheme reduces the incidence of node compromise and replication attacks. The scheme also provides a malicious-node detection and warning mechanism, which can quickly identify compromised static nodes and immediately alert the administrative department. With performance evaluations, the scheme can obtain better trade-offs between security and efficiency than the well-known available schemes. PMID:29324719

  20. An Enhanced Secure Identity-Based Certificateless Public Key Authentication Scheme for Vehicular Sensor Networks.

    PubMed

    Li, Congcong; Zhang, Xi; Wang, Haiping; Li, Dongfeng

    2018-01-11

    Vehicular sensor networks have been widely applied in intelligent traffic systems in recent years. Because of the specificity of vehicular sensor networks, they require an enhanced, secure and efficient authentication scheme. Existing authentication protocols are vulnerable to some problems, such as a high computational overhead with certificate distribution and revocation, strong reliance on tamper-proof devices, limited scalability when building many secure channels, and an inability to detect hardware tampering attacks. In this paper, an improved authentication scheme using certificateless public key cryptography is proposed to address these problems. A security analysis of our scheme shows that our protocol provides an enhanced secure anonymous authentication, which is resilient against major security threats. Furthermore, the proposed scheme reduces the incidence of node compromise and replication attacks. The scheme also provides a malicious-node detection and warning mechanism, which can quickly identify compromised static nodes and immediately alert the administrative department. With performance evaluations, the scheme can obtain better trade-offs between security and efficiency than the well-known available schemes.

  1. 30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Fire suppression devices; extinguishant supply systems. (a) Fire suppression systems using water or... equivalent protective devices and a rising stem or other visual indicator-type shutoff valve. (b) Water supplies for fire suppression devices installed on underground equipment may be maintained in mounted water...

  2. 30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Fire suppression devices; extinguishant supply systems. (a) Fire suppression systems using water or... equivalent protective devices and a rising stem or other visual indicator-type shutoff valve. (b) Water supplies for fire suppression devices installed on underground equipment may be maintained in mounted water...

  3. 30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Fire suppression devices; extinguishant supply systems. (a) Fire suppression systems using water or... equivalent protective devices and a rising stem or other visual indicator-type shutoff valve. (b) Water supplies for fire suppression devices installed on underground equipment may be maintained in mounted water...

  4. [Functional recordings of human nasal inferior turbinates -- the device design].

    PubMed

    Mikulewicz, W; Galasiński, J

    1993-01-01

    There is prototype of device presented. It is used in order to record a simultaneous capacitance and resistance vessels functions, of human inferior turbinate. Present results indicate usefulness of device in clinical trials.

  5. Passive Microfluidic device for Sub Millisecond Mixing

    PubMed Central

    McMahon, Jay; Mohamed, Hisham; Barnard, David; Shaikh, Tanvir R.; Mannella, Carmen A.; Wagenknecht, Terence; Lu, Toh-Ming

    2009-01-01

    We report the investigation of a novel microfluidic mixing device to achieve submillisecond mixing. The micromixer combines two fluid streams of several microliters per second into a mixing compartment integrated with two T- type premixers and 4 butterfly-shaped in-channel mixing elements. We have employed three dimensional fluidic simulations to evaluate the mixing efficiency, and have constructed physical devices utilizing conventional microfabrication techniques. The simulation indicated thorough mixing at flow rate as low as 6 µL/s. The corresponding mean residence time is 0.44 ms for 90% of the particles simulated, or 0.49 ms for 95% of the particles simulated, respectively. The mixing efficiency of the physical device was also evaluated using fluorescein dye solutions and FluoSphere-red nanoparticles suspensions. The constructed micromixers achieved thorough mixing at the same flow rate of 6 µL/s, with the mixing indices of 96% ± 1%, and 98% ± 1% for the dye and the nanoparticle, respectively. The experimental results are consistent with the simulation data. The device demonstrated promising capabilities for time resolved studies for macromolecular dynamics of biological macromolecules. PMID:20161619

  6. Colonoscopic full-thickness resection using an over-the-scope device: a prospective multicentre study in various indications.

    PubMed

    Schmidt, Arthur; Beyna, Torsten; Schumacher, Brigitte; Meining, Alexander; Richter-Schrag, Hans-Juergen; Messmann, Helmut; Neuhaus, Horst; Albers, David; Birk, Michael; Thimme, Robert; Probst, Andreas; Faehndrich, Martin; Frieling, Thomas; Goetz, Martin; Riecken, Bettina; Caca, Karel

    2017-08-10

    Endoscopic full-thickness resection (EFTR) is a novel treatment of colorectal lesions not amenable to conventional endoscopic resection. The aim of this prospective multicentre study was to assess the efficacy and safety of the full-thickness resection device. 181 patients were recruited in 9 centres with the indication of difficult adenomas (non-lifting and/or at difficult locations), early cancers and subepithelial tumours (SET). Primary endpoint was complete en bloc and R0 resection. EFTR was technically successful in 89.5%, R0 resection rate was 76.9%. In 127 patients with difficult adenomas and benign histology, R0 resection rate was 77.7%. In 14 cases, lesions harboured unsuspected cancer, another 15 lesions were primarily known as cancers. Of these 29 cases, R0 resection was achieved in 72.4%; 8 further cases had deep submucosal infiltration >1000 µm. Therefore, curative resection could only be achieved in 13/29 (44.8%). In the subgroup with SET (n=23), R0 resection rate was 87.0%. In general, R0 resection rate was higher with lesions ≤2 cm vs >2 cm (81.2% vs 58.1%, p=0.0038). Adverse event rate was 9.9% with a 2.2% rate of emergency surgery. Three-month follow-up was available from 154 cases and recurrent/residual tumour was evident in 15.3%. EFTR has a reasonable technical efficacy especially in lesions ≤2 cm with acceptable complication rates. Curative resection rate for early cancers was too low to recommend its primary use in this indication. Further comparative studies have to show the clinical value and long-term outcome of EFTR in benign colorectal lesions. NCT02362126; Results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. The radon indicator

    NASA Astrophysics Data System (ADS)

    Samuelsson, L.

    2005-11-01

    The radon indicator is an efficient instrument for measuring the radon daughter concentrations in a house or dwelling. Physics or environmental science students could build a radon indicator as a student project. Another possibility would be to use a radon indicator in a student investigation of radon levels in different houses. Finally the radon indicator is an excellent device for producing a radioactive source, free of charge, for the study of α-, β- and γ-radiation. The half-life of the activity collected is approximately 40 min. The radon indicator makes use of an electrostatic method by which charged particles are drawn to a small aluminium plate with a high negative voltage (-5 kV), thus creating a strong electric field between the plate and a surrounding copper wire. The radioactivity on the plate is subsequently measured by a GM-counter and the result calculated in Bq m-3. The collecting time is just 5.5 min and therefore the instrument is only suitable for use in a short-time method for indicating the radon concentration. An improved diagram, ground-radon and/or wall-radon in houses, is presented on the basis of the author's measurements recorded with the radon indicator over many years. This diagram is very useful when discussing how to reduce radiation levels in homes.

  8. Value-based procurement of medical devices: Application to devices for mechanical thrombectomy in ischemic stroke.

    PubMed

    Trippoli, Sabrina; Caccese, Erminia; Marinai, Claudio; Messori, Andrea

    2018-03-01

    In the acute ischemic stroke, endovascular devices have shown promising clinical results and are also likely to represent value for money, as several modeling studies have shown. Pharmacoeconomic evaluations in this field, however, have little impact on the procurement of these devices. The present study explored how complex pharmacoeconomic models that evaluate effectiveness and cost can be incorporated into the in-hospital procurement of thrombectomy devices. As regards clinical modeling, we extracted outcomes at three months from randomized trials conducted for four thrombectomy devices, and we projected long-term results using standard Markov modeling. In estimating QALYs, the same model was run for the four devices. As regards economic modeling, we firstly estimated for each device the net monetary benefit (NMB) per patient (threshold = $60,000 per QALY); then, we simulated a competitive tender across the four products by determining the tender-based score (on a 0-to-100 scale). Prices of individual devices were obtained from manufacturers. Extensive sensitivity testing was applied to our analyses. For the four devices (Solitaire, Trevo, Penumbra, Solumbra), QALYs were 1.86, 1.52, 1,79, 1.35, NMB was $101,824, $83,546, $101,923, $69,440, and tender-based scores were 99.70, 43.43, 100, 0, respectively. Sensitivity analysis confirmed findings from base-case. Our results indicate that, in the field of thrombectomy devices, incorporating the typical tools of cost-effectiveness into the processes of tenders and procurement is feasible. Bridging the methodology of cost-effectiveness with the every-day practice of in-hospital procurement can contribute to maximizing the health returns that are generated by in-hospital expenditures for medical devices. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. The Role of a Mental Model in Learning to Operate a Device.

    ERIC Educational Resources Information Center

    Kieras, David E.; Bovair, Susan

    1984-01-01

    Describes three studies concerned with learning to operate a control panel device and how this learning is affected by understanding a device model that describes its internal mechanism. Results indicate benefits of a device model depend on whether it supports direct inference of exact steps required to operate the device. (Author/MBR)

  10. Development of a reversible vas deferens occlusive device. VI. Long-term evaluation of flexible prosthetic devices.

    PubMed

    Brueschke, E E; Zaneveld, L J; Kaleckas, R A; Wingfield, J R

    1979-05-01

    Fifty-three dogs received implants of several types of flexible devices containing valving mechanisms. These devices were constructed entirely of silicone rubber with the exception of the valve stem, which was made of stainless steel. Generally, the devices were (1) implanted in the open mode and left this way for 27 to 44 months, (2) implanted in the closed mode and kept this way for 11 to 12 months before the valves were reopened, (3) implanted in either the closed or open mode and cycled to the opposite mode every 3 months (four or five cycles), or (4) implanted in either the closed or open mode and cycled to the opposite mode every 6 months (two or three cycles). Different implant methods were also evaluated. Semen analyses were regularly performed on all of the dogs, and a number of the animals were bred during the experiments. It can be concluded that (1) the devices can be opened and closed successfully over long periods, respectively allowing and preventing sperm transport; (2) the breeding ability of the animals is not impaired while the devices are in the open mode, independent of the type of device; (3) the devices do not result in an enhanced incidence of congenital abnormalities in the offspring; and (4) the success rate of device performance does not depend on the method of implanatation used. Thus, the results clearly indicate that the basic mechanism of a soft, reversible valve is a feasible approach to conception control.

  11. Practice of Regulatory Science (Development of Medical Devices).

    PubMed

    Niimi, Shingo

    2017-01-01

    Prototypes of medical devices are made in accordance with the needs of clinical practice, and for systems required during the initial process of medical device development for new surgical practices. Verification of whether these prototypes produce the intended performance specifications is conducted using basic tests such as mechanical and animal tests. The prototypes are then improved and modified until satisfactory results are obtained. After a prototype passes through a clinical trial process similar to that for new drugs, application for approval is made. In the approval application process, medical devices are divided into new, improved, and generic types. Reviewers judge the validity of intended use, indications, operation procedures, and precautions, and in addition evaluate the balance between risk and benefit in terms of efficacy and safety. Other characteristics of medical devices are the need for the user to attain proficiency in usage techniques to ensure efficacy and safety, and the existence of a variety of medical devices for which assessment strategies differ, including differences in impact on the body in cases in which a physical burden to the body or failure of a medical device develops. Regulatory science of medical devices involves prediction, judgment, and evaluation of efficacy, safety, and quality, from which data result which can become indices in the development stages from design to application for approval. A reduction in the number of animals used for testing, improvement in efficiency, reduction of the necessity for clinical trials, etc. are expected through rational setting of evaluation items.

  12. Integrated device architectures for electrochromic devices

    DOEpatents

    Frey, Jonathan Mack; Berland, Brian Spencer

    2015-04-21

    This disclosure describes systems and methods for creating monolithically integrated electrochromic devices which may be a flexible electrochromic device. Monolithic integration of thin film electrochromic devices may involve the electrical interconnection of multiple individual electrochromic devices through the creation of specific structures such as conductive pathway or insulating isolation trenches.

  13. 49 CFR 236.513 - Audible indicator.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.513 Audible indicator. (a) The automatic cab signal... control system shall have a distinctive sound and be clearly audible throughout the cab under all...

  14. 49 CFR 236.513 - Audible indicator.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.513 Audible indicator. (a) The automatic cab signal... control system shall have a distinctive sound and be clearly audible throughout the cab under all...

  15. 14 CFR 29.1413 - Safety belts: passenger warning device.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Safety belts: passenger warning device. 29.1413 Section 29.1413 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF....1413 Safety belts: passenger warning device. (a) If there are means to indicate to the passengers when...

  16. 14 CFR 29.1413 - Safety belts: passenger warning device.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Safety belts: passenger warning device. 29.1413 Section 29.1413 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF....1413 Safety belts: passenger warning device. (a) If there are means to indicate to the passengers when...

  17. 14 CFR 29.1413 - Safety belts: passenger warning device.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Safety belts: passenger warning device. 29.1413 Section 29.1413 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF....1413 Safety belts: passenger warning device. (a) If there are means to indicate to the passengers when...

  18. 14 CFR 29.1413 - Safety belts: passenger warning device.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Safety belts: passenger warning device. 29.1413 Section 29.1413 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF....1413 Safety belts: passenger warning device. (a) If there are means to indicate to the passengers when...

  19. 14 CFR 29.1413 - Safety belts: passenger warning device.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Safety belts: passenger warning device. 29.1413 Section 29.1413 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF....1413 Safety belts: passenger warning device. (a) If there are means to indicate to the passengers when...

  20. Method and device for identifying different species of honeybees

    DOEpatents

    Kerr, Howard T.; Buchanan, Michael E.; Valentine, Kenneth H.

    1989-01-01

    A method and device have been provided for distinguishing Africanized honeybees from European honeybees. The method is based on the discovery of a distinct difference in the acoustical signatures of these two species of honeybees in flight. The European honeybee signature has a fundamental power peak in the 210 to 240 Hz range while the Africanized honeybee signature has a fundamental power peak in the 260 to 290 Hz range. The acoustic signal produced by honeybees is analyzed by means of a detecting device to quickly determine the honeybee species through the detection of the presence of frequencies in one of these distinct ranges. The device includes a microphone for acoustical signal detection which feeds the detected signal into a frequency analyzer which is designed to detect the presence of either of the known fundamental wingbeat frequencies unique to the acoustical signatures of these species as an indication of the identity of the species and indicate the species identity on a readout device.

  1. Beta ray flux measuring device

    DOEpatents

    Impink, Jr., Albert J.; Goldstein, Norman P.

    1990-01-01

    A beta ray flux measuring device in an activated member in-core instrumentation system for pressurized water reactors. The device includes collector rings positioned about an axis in the reactor's pressure boundary. Activated members such as hydroballs are positioned within respective ones of the collector rings. A response characteristic such as the current from or charge on a collector ring indicates the beta ray flux from the corresponding hydroball and is therefore a measure of the relative nuclear power level in the region of the reactor core corresponding to the specific exposed hydroball within the collector ring.

  2. Evaluation of Abuse-Deterrent or Tamper-Resistant Opioid Formulations on Overall Health Care Expenditures in a State Medicaid Program.

    PubMed

    Keast, Shellie L; Owora, Arthur; Nesser, Nancy; Farmer, Kevin

    2016-04-01

    The development of abuse-deterrent opioid prescription medications is a priority at the national level. Pharmaceutical manufacturers have begun marketing new formulations of currently available opioids that meet higher abuse resistance standards. Little information is available regarding the impact of these formulations on overall health care expenditures. To (a) examine the relationship between health care expenditures and use of brand abuse-deterrent or tamper-resistant (ADTR) extended-release opioids versus standard dosage form (SDF) extended-release opioids in a state Medicaid population, and (b) determine whether this relationship was influenced by member-specific characteristics. The study is a cross-sectional review of Oklahoma Medicaid members (aged ≥ 21 years) with at least 1 paid pharmacy claim for long-acting opioids between September 2013 and August 2014. Members who were adherent to extended-release opioid products were classified into ADTR and SDF opioid groups. The relationship between health care expenditures (prescription, medical, and overall) and opioid groups was examined using multiple linear regression models. The impact of member-specific characteristics (age, sex, race, urban classifications, and various comorbidities) on this relationship was examined. Prescription spending ($9,265,554) accounted for 35% of overall health care expenditures ($26,304,693) among 938 members during the 12-month reference period. Total prescription expenditures were higher among ADTR than SDF user groups, and the difference in median expenditures between these 2 groups was larger among members with more comorbidities, as measured by the Charlson Comorbidity Index score. Overall, ADTR users had higher median total health care and medical expenditures, and the difference in median expenditures was dependent on whether a member had comorbidities of addiction or not (higher expenditures were observed among members with comorbidities of addiction). The abuse and

  3. Device for testing continuity and/or short circuits in a cable

    NASA Technical Reports Server (NTRS)

    Hayhurst, Arthur R. (Inventor)

    1995-01-01

    A device for testing current paths is attachable to a conductor. The device automatically checks the current paths of the conductor for continuity of a center conductor, continuity of a shield and a short circuit between the shield and the center conductor. The device includes a pair of connectors and a circuit to provide for testing of the conductive paths of the cable. The pair of connectors electrically connects the conductive paths of a cable to be tested with the circuit paths of the circuit. The circuit paths in the circuit include indicators to simultaneously indicate the results of the testing.

  4. 21 CFR 1309.71 - General security requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... guard against theft and diversion of List I chemicals. Chemicals must be stored in containers sealed in such a manner as to indicate any attempts at tampering with the container. Where chemicals cannot be stored in sealed containers, access to the chemicals should be controlled through physical means or...

  5. 21 CFR 1309.71 - General security requirements.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... guard against theft and diversion of List I chemicals. Chemicals must be stored in containers sealed in such a manner as to indicate any attempts at tampering with the container. Where chemicals cannot be stored in sealed containers, access to the chemicals should be controlled through physical means or...

  6. 21 CFR 1309.71 - General security requirements.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... guard against theft and diversion of List I chemicals. Chemicals must be stored in containers sealed in such a manner as to indicate any attempts at tampering with the container. Where chemicals cannot be stored in sealed containers, access to the chemicals should be controlled through physical means or...

  7. 21 CFR 1309.71 - General security requirements.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... guard against theft and diversion of List I chemicals. Chemicals must be stored in containers sealed in such a manner as to indicate any attempts at tampering with the container. Where chemicals cannot be stored in sealed containers, access to the chemicals should be controlled through physical means or...

  8. 21 CFR 1309.71 - General security requirements.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... guard against theft and diversion of List I chemicals. Chemicals must be stored in containers sealed in such a manner as to indicate any attempts at tampering with the container. Where chemicals cannot be stored in sealed containers, access to the chemicals should be controlled through physical means or...

  9. Compact programmable photonic variable delay devices

    NASA Technical Reports Server (NTRS)

    Yao, X. Steve (Inventor)

    1999-01-01

    Optical variable delay devices for providing variable true time delay to multiple optical beams simultaneously. A ladder-structured variable delay device comprises multiple basic building blocks stacked on top of each other resembling a ladder. Each basic building block has two polarization beamsplitters and a polarization rotator array arranged to form a trihedron; Controlling an array element of the polarization rotator array causes a beam passing through the array element either going up to a basic building block above it or reflect back towards a block below it. The beams going higher on the ladder experience longer optical path delay. An index-switched optical variable delay device comprises of many birefringent crystal segments connected with one another, with a polarization rotator array sandwiched between any two adjacent crystal segments. An array element in the polarization rotator array controls the polarization state of a beam passing through the element, causing the beam experience different refractive indices or path delays in the following crystal segment. By independently control each element in each polarization rotator array, variable optical path delays of each beam can be achieved. Finally, an index-switched variable delay device and a ladder-structured variable device are cascaded to form a new device which combines the advantages of the two individual devices. This programmable optic device has the properties of high packing density, low loss, easy fabrication, and virtually infinite bandwidth. The device is inherently two dimensional and has a packing density exceeding 25 lines/cm.sup.2. The delay resolution of the device is on the order of a femtosecond (one micron in space) and the total delay exceeds 10 nanosecond. In addition, the delay is reversible so that the same delay device can be used for both antenna transmitting and receiving.

  10. Failure Mechanisms for III-Nitride HEMT Devices

    DTIC Science & Technology

    2013-11-19

    rf plasma-assisted molecular beam epitaxy on freestanding GaN substrates, J. Cryst. Growth 380, 14-17 (2013). ii) Conference presentations (Invited...1 eFinal Report – AOARD Grant FA-2386-11-1-4107 Failure Mechanisms for III-nitride HEMT devices 19 November 2013 Principal Investigators: Martha...aspects of III-nitride HEMT materials and devices. Energy-filtered imaging of unstressed and stressed Ni/Au-gated AlGaN/GaN HEMTs indicated that

  11. Batteries used to Power Implantable Biomedical Devices

    PubMed Central

    Bock, David C.; Marschilok, Amy C.; Takeuchi, Kenneth J.; Takeuchi, Esther S.

    2012-01-01

    Battery systems have been developed that provide years of service for implantable medical devices. The primary systems utilize lithium metal anodes with cathode systems including iodine, manganese oxide, carbon monofluoride, silver vanadium oxide and hybrid cathodes. Secondary lithium ion batteries have also been developed for medical applications where the batteries are charged while remaining implanted. While the specific performance requirements of the devices vary, some general requirements are common. These include high safety, reliability and volumetric energy density, long service life, and state of discharge indication. Successful development and implementation of these battery types has helped enable implanted biomedical devices and their treatment of human disease. PMID:24179249

  12. Batteries used to Power Implantable Biomedical Devices.

    PubMed

    Bock, David C; Marschilok, Amy C; Takeuchi, Kenneth J; Takeuchi, Esther S

    2012-12-01

    Battery systems have been developed that provide years of service for implantable medical devices. The primary systems utilize lithium metal anodes with cathode systems including iodine, manganese oxide, carbon monofluoride, silver vanadium oxide and hybrid cathodes. Secondary lithium ion batteries have also been developed for medical applications where the batteries are charged while remaining implanted. While the specific performance requirements of the devices vary, some general requirements are common. These include high safety, reliability and volumetric energy density, long service life, and state of discharge indication. Successful development and implementation of these battery types has helped enable implanted biomedical devices and their treatment of human disease.

  13. A digital indicator for maximum windspeeds.

    Treesearch

    William B. Fowler

    1969-01-01

    A simple device for indicating maximum windspeed during a time interval is described. Use of a unijunction transistor, for voltage sensing, results in a stable comparison circuit and also reduces overall component requirements. Measurement is presented digitally in 1-mile-per-hour increments over the range of 0-51 m.p.h.

  14. Facial expressions and speech acts: experimental evidences on the role of the upper face as an illocutionary force indicating device in language comprehension.

    PubMed

    Domaneschi, Filippo; Passarelli, Marcello; Chiorri, Carlo

    2017-08-01

    Language scientists have broadly addressed the problem of explaining how language users recognize the kind of speech act performed by a speaker uttering a sentence in a particular context. They have done so by investigating the role played by the illocutionary force indicating devices (IFIDs), i.e., all linguistic elements that indicate the illocutionary force of an utterance. The present work takes a first step in the direction of an experimental investigation of non-verbal IFIDs because it investigates the role played by facial expressions and, in particular, of upper-face action units (AUs) in the comprehension of three basic types of illocutionary force: assertions, questions, and orders. The results from a pilot experiment on production and two comprehension experiments showed that (1) certain upper-face AUs seem to constitute non-verbal signals that contribute to the understanding of the illocutionary force of questions and orders; (2) assertions are not expected to be marked by any upper-face AU; (3) some upper-face AUs can be associated, with different degrees of compatibility, with both questions and orders.

  15. Chronic, intermittent convection-enhanced delivery devices.

    PubMed

    Lewis, Owen; Woolley, Max; Johnson, David; Rosser, Anne; Barua, Neil U; Bienemann, Alison S; Gill, Steven S; Evans, Sam

    2016-02-01

    Intraparenchymal convection-enhanced delivery (CED) of therapeutics directly into the brain has long been endorsed as a medium through which meaningful concentrations of drug can be administered to patients, bypassing the blood brain barrier. The translation of the technology to clinic has been hindered by poor distribution not previously observed in smaller pre-clinical models. In part this was due to the larger volumes of target structures found in humans but principally the poor outcome was linked to reflux (backflow) of infusate proximally along the catheter track. Over the past 10 years, improvements have been made to the technology in the field which has led to a small number of commercially available devices containing reflux inhibiting features. While these devices are currently suitable for acute or short term use, several indications would benefit from longer term repeated, intermittent administration of therapeutics (Parkinson's, Alzheimer's, Amyotrophic lateral sclerosis, Brain tumours such as Glioblastoma Multiforme (GBM) and Diffuse intrinsic Pontine Glioma (DIPG), etc.). Despite the need for a chronically accessible platform for such indications, limited experience exists in this part of the field. At the time of writing no commercially available clinical platform, indicated for chronic, intermittent or continuous delivery to the brain exists. Here we review the improvements that have been made to CED devices over recent years and current state of the art for chronic infusion systems. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  16. A Case for Tamper-Resistant and Tamper-Evident Computer Systems

    DTIC Science & Technology

    2007-02-01

    such as Kerberos is hard to apply [2] B . Gassend, G. Sub, D. Clarke, M. Dijk, and S. Devadas . Caches and Hash Trees for Efficient Memory Integrity...the block’s data from DRAM. For authentication, Merkle [14] G. Suh, D. Clarke, B . Gassend, M. van Dijk, and S. Devadas . Efficient Memory Integrity...wwi4serverwatch.com/news/article.php/ tion where a data block is encrypted or decrypted through an XOR 1399451, 2000. [11] B . Rogers, Y. Solihin

  17. Mobile health devices: will patients actually use them?

    PubMed

    Shaw, Ryan J; Steinberg, Dori M; Bonnet, Jonathan; Modarai, Farhad; George, Aaron; Cunningham, Traven; Mason, Markedia; Shahsahebi, Mohammad; Grambow, Steven C; Bennett, Gary G; Bosworth, Hayden B

    2016-05-01

    Although mobile health (mHealth) devices offer a unique opportunity to capture patient health data remotely, it is unclear whether patients will consistently use multiple devices simultaneously and/or if chronic disease affects adherence. Three healthy and three chronically ill participants were recruited to provide data on 11 health indicators via four devices and a diet app. The healthy participants averaged overall weekly use of 76%, compared to 16% for those with chronic illnesses. Device adherence declined across all participants during the study. Patients with chronic illnesses, with arguably the most to benefit from advanced (or increased) monitoring, may be less likely to adopt and use these devices compared to healthy individuals. Results suggest device fatigue may be a significant problem. Use of mobile technologies may have the potential to transform care delivery across populations and within individuals over time. However, devices may need to be tailored to meet the specific patient needs. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Safety of a progesterone-releasing intravaginal device as assessed from vaginal mucosal integrity and indicators of systemic inflammation in postpartum dairy cows

    PubMed Central

    Walsh, Robert B.; LeBlanc, Stephen J.; Vernooy, Erin; Leslie, Kenneth E.

    2008-01-01

    A clinical trial was conducted to investigate the animal safety of a progesterone-releasing intravaginal device (PRID). Anestrus cows at a mean of 63 ± 3.5 d in milk were randomly assigned to an ovulation-synchronization protocol that included placement of either a PRID or a placebo intravaginal device (PID) or no such treatment. At enrolment and at device removal 7 d later, blood samples were collected. The outcomes of interest included the vaginal reaction to the device, the vaginal mucosal integrity, and the results of bacterial culture of swabs of the vaginal mucosa. In addition, the leukocyte and haptoglobin responses were measured. Although only 5% of the PRID-treated animals compared with 19% of the PID-treated animals had a copious purulent vaginal discharge at the time of device removal, there was no significant difference in the proportions; furthermore, there was no evidence of vaginal mucosal damage associated with either device. The total blood leukocyte count was significantly lower in both the PRID-treated cows and the PID-treated cows after device removal compared with the start of treatment (P < 0.05) and compared with no treatment (P < 0.001); there was no difference in leukocyte response between the 2 device-treated groups. The decrease in leukocyte count was attributed to a significant reduction in the numbers of circulating neutrophils and lymphocytes, a pattern consistent with the luteal phase of the bovine estrus cycle. There was no significant difference in the circulating haptoglobin concentration between the 3 groups of cows. Culture revealed commensal bacterial growth in the vagina of all the cows. PMID:18214161

  19. Exposed Subcutaneous Implantable Devices: An Operative Protocol for Management and Salvage

    PubMed Central

    D’Arpa, Salvatore; Cordova, Adriana; Moschella, Francesco

    2015-01-01

    Background: Implantable venous and electrical devices are prone to exposure and infection. Indications for management are controversial, but—especially if infected—exposed devices are often removed and an additional operation is needed to replace the device, causing a delay in chemotherapy and prolonging healing time. We present our protocol for device salvage, on which limited literature is available. Methods: Between 2007 and 2013, 17 patients were treated (12 venous access ports, 3 cardiac pacemakers, and 2 subcutaneous neural stimulators). Most patients were operated within 7 days from exposure. All patients received only a single perioperative dose of prophylactic antibiotic. In cases of gross infection (n = 1), the device was immediately replaced. In the absence of clinical signs of infection: Complete capsulectomy and aggressive cleaning with an n-acetylcysteine solution and saline solution. Primary exposure of venous ports with sufficient skin coverage (n = 10): the device was covered with local skin flaps. Recurrent cases, cases with insufficient skin coverage or big devices (n = 7): the device was moved to a subpectoral pocket. Mean follow-up was 19 months. Results: Sixteen devices were saved. Only one grossly infected pacemaker was removed and replaced immediately. Only in 1 case, exposure of a venous port recurred after 18 months and was successfully moved to a subpectoral pocket. Chemotherapy was always restarted as scheduled and electrical devices remained functional. Conclusions: This protocol allows—with a straightforward operation and simple measures—to save exposed devices even several days after exposure. Submuscular placement or immediate replacement is indicated only in selected cases. PMID:26034650

  20. User-Wearable Devices that Monitor Exposure to Blue Light and Recommend Adjustments Thereto

    NASA Technical Reports Server (NTRS)

    Lee, Yong Jin (Inventor)

    2017-01-01

    Described herein are user-wearable devices that include an optical sensor, and methods for use therewith. In certain embodiments, an optical sensor of a user-wearable device (e.g., a wrist-worn device) is used to detect blue light that is incident on the optical sensor and to produce a blue light detection signal indicative thereof, and thus, indicative of the response of the user's intrinsically photosensitive Retinal Ganglion Cells (ipRGCs). In dependence on the blue light detection signal, there is a determination of a metric indicative of an amount of blue light detected by the optical sensor. The metric is compared to a corresponding threshold, and a user notification is triggered in dependence on results of the comparing, wherein the user notification informs a person wearing the user-wearable device to adjust their exposure to light.

  1. Rapid Detection of Microbial Contamination Using a Microfluidic Device.

    PubMed

    Al-Adhami, Mustafa; Tilahun, Dagmawi; Rao, Govind; Gurramkonda, Chandrasekhar; Kostov, Yordan

    2017-01-01

    A portable kinetics fluorometer is developed to detect viable cells which may be contaminating various samples. The portable device acts as a single-excitation, single-emission photometer that continuously measures fluorescence intensity of an indicator dye and plots it. The slope of the plot depends on the number of colony forming units per milliliter. The device uses resazurin as the indicator dye. Viable cells reduce resazurin to resorufin, which is more fluorescent. Photodiode is used to detect fluorescence change. The photodiode generated current proportional to the intensity of the light that reached it, and an op-amp is used in a transimpedance differential configuration to ensure amplification of the photodiode's signal. A microfluidic chip is designed specifically for the device. It acts as a fully enclosed cuvette, which enhances the resazurin reduction rate. In tests, the E. coli-containing media are injected into the microfluidic chip and the device is able to detect the presence of E. coli in LB media based on the fluorescence change that occurred in the indicator dye. The device provides fast, accurate, and inexpensive means to optical detection of the presence of viable cells and could be used in the field in place of more complex methods, i.e., loop-meditated isothermal amplification of DNA (LAMP) to detect bacteria in pharmaceutical samples (Jimenez et al., J Microbiol Methods 41(3):259-265, 2000) or measuring the intrinsic fluorescence of the bacterial or yeast chromophores (Estes et al., Biosens Bioelectron 18(5):511-519, 2003).

  2. Device Longevity in a Contemporary Cohort of ICD/CRT-D Patients Undergoing Device Replacement.

    PubMed

    Zanon, Francesco; Martignani, Cristian; Ammendola, Ernesto; Menardi, Endrj; Narducci, Maria Lucia; DE Filippo, Paolo; Santamaria, Matteo; Campana, Andrea; Stabile, Giuseppe; Potenza, Domenico Rosario; Pastore, Gianni; Iori, Matteo; LA Rosa, Concetto; Biffi, Mauro

    2016-07-01

    The longevity of defibrillators (ICD) is extremely important from both a clinical and economic perspective. We studied the reasons for device replacement, the longevity of removed ICD, and the existence of possible factors associated with shorter service life. Consecutive patients who underwent ICD replacement from March 2013 to May 2015 in 36 Italian centers were included in this analysis. Data on replaced devices were collected. A total of 953 patients were included in this analysis. In 813 (85%) patients the reason for replacement was battery depletion, while 88 (9%) devices were removed for clinical reasons and the remaining 52 because of system failure (i.e., lead or ICD generator failure or a safety advisory indication). The median service life was 5.9 years (25th-75th percentile, 4.9-6.9) for single- and dual-chamber ICD and 4.9 years (25th-75th percentile, 4.0-5.7) for CRT-D. On multivariate analysis, the factors CRT-D device, SC/DC ICD generator from Biotronik, percentage of ventricular pacing, and the occurrence of a system failure were positively associated with a replacement procedure. By contrast, the device from Boston Scientific was an independent protective factor against replacement. Considerable differences were seen in battery duration in both ICD and CRT-D. Specifically, Biotronik devices showed the shortest longevity among ICD and Boston Scientific showed the longest longevity among CRT-D (log-rank test, P < 0.001 for pairwise comparisons). Several factors were associated with shorter service life of ICD devices: CRT-D, occurrence of system failure and percentage of ventricular pacing. Our results confirmed significant differences among manufacturers. © The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals, Inc.

  3. Multi-Center, Community-Based Cardiac Implantable Electronic Devices Registry: Population, Device Utilization, and Outcomes.

    PubMed

    Gupta, Nigel; Kiley, Mary Lou; Anthony, Faith; Young, Charlie; Brar, Somjot; Kwaku, Kevin

    2016-03-09

    The purpose of this study is to describe key elements, clinical outcomes, and potential uses of the Kaiser Permanente-Cardiac Device Registry. This is a cohort study of implantable cardioverter defibrillators (ICD), pacemakers (PM), and cardiac resynchronization therapy (CRT) devices implanted between January 1, 2007 and December 31, 2013 by ≈400 physicians in 6 US geographical regions. Registry data variables, including patient characteristics, comorbidities, indication for procedures, complications, and revisions, were captured using the healthcare system's electronic medical record. Outcomes were identified using electronic screening algorithms and adjudicated via chart review. There were 11 924 ICDs, 33 519 PMs, 4472 CRTs, and 66 067 leads registered. A higher proportion of devices were implanted in males: 75.1% (ICD), 55.0% (PM), and 66.7% (CRT), with mean patient age 63.2 years (ICD), 75.2 (PM), and 67.2 (CRT). The 30-day postoperative incidence of tamponade, hematoma, and pneumothorax were ≤0.3% (ICD), ≤0.6% (PM), and ≤0.4% (CRT). Device failures requiring revision occurred at a rate of 2.17% for ICDs, 0.85% for PMs, and 4.93% for CRTs, per 100 patient observation years. Superficial infection rates were <0.03% for all devices; deep infection rates were 0.6% (ICD), 0.5% (PM), and 1.0% (CRT). Results were used to monitor vendor-specific variations and were systematically shared with individual regions to address potential variations in outcomes, utilization, and to assist with the management of device recalls. The Kaiser Permanente-Cardiac Device Registry is a robust tool to monitor postprocedural patient outcomes and postmarket surveillance of implants and potentially change practice patterns. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  4. 47 CFR 1.549 - Requests for extension of authority to operate without required monitors, indicating instruments...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Requests for extension of authority to operate without required monitors, indicating instruments, and EBS Attention Signal devices. 1.549 Section 1.549... required monitors, indicating instruments, and EBS Attention Signal devices. See § 73.3549. ...

  5. External shading devices for energy efficient building

    NASA Astrophysics Data System (ADS)

    Shahdan, M. S.; Ahmad, S. S.; Hussin, M. A.

    2018-02-01

    External shading devices on a building façade is an important passive design strategy as they reduce solar radiation. Although studies have proven the benefits of external shading devices, many are designed solely for aesthetic purposes without fully considering its high potential to reduce solar radiation and glare. Furthermore, explorations into shading devices by the design team are mostly left too late in the design development phases. Hence, the paper looks into the effectiveness of external shading devices on a building towards more energy efficient building. The study aims to analyse the effects of various configurations of external shading devices towards the energy consumption of a case study building based on computer simulations. This study uses Building Information Modelling (BIM) through Autodesk Revit software as simulation tool. The constant variables for the simulation are the orientation of the building, types of glazing used by the building and the internal loads of the building. Whereas, the manipulated variable is the types of shading device used. The data were sorted according to the categories and translated into a chart. Analysis of the findings indicate that shading devices with different configurations show significant results in the energy consumption and the best configuration is the egg-crate shading devices. The study recommends that the consideration for shading device as a passive design strategy needs to be developed at the early stage of the building design.

  6. Rotary mechanical latch

    DOEpatents

    Spletzer, Barry L.; Martinez, Michael A.; Marron, Lisa C.

    2012-11-13

    A rotary mechanical latch for positive latching and unlatching of a rotary device with a latchable rotating assembly having a latching gear that can be driven to latched and unlatched states by a drive mechanism such as an electric motor. A cam arm affixed to the latching gear interfaces with leading and trailing latch cams affixed to a flange within the drive mechanism. The interaction of the cam arm with leading and trailing latch cams prevents rotation of the rotating assembly by external forces such as those due to vibration or tampering.

  7. Active Time-Domain Reflectometry for Unattended Safeguards Systems: FY16 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tedeschi, Jonathan R.; Smith, Leon E.; Conrad, Ryan C.

    2016-10-21

    The International Atomic Energy Agency (IAEA) continues to expand its use of unattended measurement systems. An increasing number of systems and an expanding family of instruments create challenges in terms of deployment efficiency and the implementation of data authentication measures. Traditional data security measures, for example tamper-indicating (TI) conduit, are impractical for the long separation distances (often 100 meters or more) between unattended monitoring system (UMS) components. Pacific Northwest National Laboratory (PNNL) is studying the viability of active time-domain reflectometry (TDR) for the detection of cable tampering in unattended radiation detection systems. The instrument concept under investigation would allow formore » unmanned cable integrity measurements, remote surveillance reporting and locating of cable faults and/or tampers. This report describes PNNL’s FY16 progress and includes: an overview of the TDR methods under investigation; description of the TDR evaluation testbed developed by PNNL; development and testing of advanced signal processing algorithms to extract weak signals from relatively high noise levels; and initial testing of a laboratory prototype intended for IAEA UMS applications and based on a commercially available TDR module. Preliminary viability findings and recommendations for the next stage of development and testing are provided.« less

  8. Mobility Device Quality Affects Participation Outcomes for People With Disabilities: A Structural Equation Modeling Analysis.

    PubMed

    Magasi, Susan; Wong, Alex; Miskovic, Ana; Tulsky, David; Heinemann, Allen W

    2018-01-01

    To test the effect that indicators of mobility device quality have on participation outcomes in community-dwelling adults with spinal cord injury, traumatic brain injury, and stroke by using structural equation modeling. Survey, cross-sectional study, and model testing. Clinical research space at 2 academic medical centers and 1 free-standing rehabilitation hospital. Community-dwelling adults (N=250; mean age, 48±14.3y) with spinal cord injury, traumatic brain injury, and stroke. Not applicable. The Mobility Device Impact Scale, Patient-Reported Outcomes Measurement Information System Social Function (version 2.0) scale, including Ability to Participate in Social Roles and Activities and Satisfaction with Social Roles and Activities, and the 2 Community Participation Indicators' enfranchisement scales. Details about device quality (reparability, reliability, ease of maintenance) and device type were also collected. Respondents used ambulation aids (30%), manual (34%), and power wheelchairs (30%). Indicators of device quality had a moderating effect on participation outcomes, with 3 device quality variables (repairability, ease of maintenance, device reliability) accounting for 20% of the variance in participation. Wheelchair users reported lower participation enfranchisement than did ambulation aid users. Mobility device quality plays an important role in participation outcomes. It is critical that people have access to mobility devices and that these devices be reliable. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  9. Temperature differential detection device

    DOEpatents

    Girling, P.M.

    1986-04-22

    A temperature differential detection device for detecting the temperature differential between predetermined portions of a container wall is disclosed as comprising a Wheatstone bridge circuit for detecting resistance imbalance with a first circuit branch having a first elongated wire element mounted in thermal contact with a predetermined portion of the container wall, a second circuit branch having a second elongated wire element mounted in thermal contact with a second predetermined portion of a container wall with the wire elements having a predetermined temperature-resistant coefficient, an indicator interconnected between the first and second branches remote from the container wall for detecting and indicating resistance imbalance between the first and second wire elements, and connector leads for electrically connecting the wire elements to the remote indicator in order to maintain the respective resistance value relationship between the first and second wire elements. The indicator is calibrated to indicate the detected resistance imbalance in terms of a temperature differential between the first and second wall portions. 2 figs.

  10. Temperature differential detection device

    DOEpatents

    Girling, Peter M.

    1986-01-01

    A temperature differential detection device for detecting the temperature differential between predetermined portions of a container wall is disclosed as comprising a Wheatstone bridge circuit for detecting resistance imbalance with a first circuit branch having a first elongated wire element mounted in thermal contact with a predetermined portion of the container wall, a second circuit branch having a second elongated wire element mounted in thermal contact with a second predetermined portion of a container wall with the wire elements having a predetermined temperature-resistant coefficient, an indicator interconnected between the first and second branches remote from the container wall for detecting and indicating resistance imbalance between the first and second wire elements, and connector leads for electrically connecting the wire elements to the remote indicator in order to maintain the respective resistance value relationship between the first and second wire elements. The indicator is calibrated to indicate the detected resistance imbalance in terms of a temperature differential between the first and second wall portions.

  11. Electronic health indicators in the selected countries: Are these indicators the best?

    PubMed

    Afshari, Somaye; Khorasani, Elahe; Yarmohammadian, Mohammad Hossein; Atighechian, Golrokh; Darab, Mohsen Ghaffari

    2013-01-01

    Many changes have been made in different sciences by developing and advancing information and communication technology in last two decades. E-health is a very broad term that includes many different activities related to the use of electronic devices, software as well as hardware in health organizations. The aim of this study is comparing electronic health indicators in the selected countries and discussion on the best indicators. This study has chosen 12 countries randomly based on the regional division of the WHO. The relevant numbers of health indicators and general indicators and information technology indicators are extracted of these countries. We use data from the Bitarf's comparative study, which is conducted by the Iranian Supreme Council of Information Technology in 2007. By using Pearson correlation test, the relations between health general indicators and IT indicators are studied. Data was analyzed based on the research objectives using SPSS software and in accordance with research questions Pearson correlation test were used. The findings show that there is a positive relation between indicators related to IT and "Total per capita health, healthy life expectancy, percent literacy". Furthermore, there is a mutual relation between IT indicators and "mortality indicator". This study showed differences between selective indicators among different countries. The modern world, with its technological advances, is not powerless in the face of these geographic and health disparity challenges. Researchers must not rely on the available indicators. They must consider indicators like e-business companies, electronic data internet, medical supplies, health electronic record, health information system, etc., In future, continuous studies in this field, to provide the exact and regular reports of amount of using of these indicators through different countries must be necessary.

  12. Low-field magnetotransport in graphene cavity devices.

    PubMed

    Zhang, G Q; Kang, N; Li, J Y; Lin, Li; Peng, Hailin; Liu, Zhongfan; Xu, H Q

    2018-05-18

    Confinement and edge structures are known to play significant roles in the electronic and transport properties of two-dimensional materials. Here, we report on low-temperature magnetotransport measurements of lithographically patterned graphene cavity nanodevices. It is found that the evolution of the low-field magnetoconductance characteristics with varying carrier density exhibits different behaviors in graphene cavity and bulk graphene devices. In the graphene cavity devices, we observed that intravalley scattering becomes dominant as the Fermi level gets close to the Dirac point. We associate this enhanced intravalley scattering to the effect of charge inhomogeneities and edge disorder in the confined graphene nanostructures. We also observed that the dephasing rate of carriers in the cavity devices follows a parabolic temperature dependence, indicating that the direct Coulomb interaction scattering mechanism governs the dephasing at low temperatures. Our results demonstrate the importance of confinement in carrier transport in graphene nanostructure devices.

  13. Low-field magnetotransport in graphene cavity devices

    NASA Astrophysics Data System (ADS)

    Zhang, G. Q.; Kang, N.; Li, J. Y.; Lin, Li; Peng, Hailin; Liu, Zhongfan; Xu, H. Q.

    2018-05-01

    Confinement and edge structures are known to play significant roles in the electronic and transport properties of two-dimensional materials. Here, we report on low-temperature magnetotransport measurements of lithographically patterned graphene cavity nanodevices. It is found that the evolution of the low-field magnetoconductance characteristics with varying carrier density exhibits different behaviors in graphene cavity and bulk graphene devices. In the graphene cavity devices, we observed that intravalley scattering becomes dominant as the Fermi level gets close to the Dirac point. We associate this enhanced intravalley scattering to the effect of charge inhomogeneities and edge disorder in the confined graphene nanostructures. We also observed that the dephasing rate of carriers in the cavity devices follows a parabolic temperature dependence, indicating that the direct Coulomb interaction scattering mechanism governs the dephasing at low temperatures. Our results demonstrate the importance of confinement in carrier transport in graphene nanostructure devices.

  14. Electronic adherence monitoring device performance and patient acceptability: a randomized control trial.

    PubMed

    Chan, Amy Hai Yan; Stewart, Alistair William; Harrison, Jeff; Black, Peter Nigel; Mitchell, Edwin Arthur; Foster, Juliet Michelle

    2017-05-01

    To investigate the performance and patient acceptability of an inhaler electronic monitoring device in a real-world childhood asthma population. Children 6 to 15 years presenting with asthma to the hospital emergency department and prescribed inhaled corticosteroids were included. Participants were randomized to receive a device with reminder features enabled or disabled for use with their preventer. Device quality control tests were conducted. Questionnaires on device acceptability, utility and ergonomics were completed at six months. A total of 1306 quality control tests were conducted; 84% passed pre-issue and 87% return testing. The most common failure reason was actuation under-recording. Acceptability scores were high, with higher scores in the reminder than non-reminder group (median, 5 th -95 th percentile: 4.1, 3.1-5.0 versus 3.7, 2.3-4.8; p < 0.001). Most (>90%) rated the device easy to use. Feedback was positive across five themes: device acceptability, ringtone acceptability, suggestions for improvement, effect on medication use, and effect on asthma control. This study investigates electronic monitoring device performance and acceptability in children using quantitative and qualitative measures. Results indicate satisfactory reliability, although failure rates of 13-16% indicate the importance of quality control. Favorable acceptability ratings support the use of these devices in children.

  15. The Infrastructure Necessary to Support a Sustainable Material Protection, Control and Accounting (MPC&A) Program in Russia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bachner, Katherine M.; Mladineo, Stephen V.

    The NNSA Material Protection, Control, and Accounting (MPC&A) program has been engaged for fifteen years in upgrading the security of nuclear materials in Russia. Part of the effort has been to establish the conditions necessary to ensure the long-term sustainability of nuclear security. A sustainable program of nuclear security requires the creation of an indigenous infrastructure, starting with sustained high level government commitment. This includes organizational development, training, maintenance, regulations, inspections, and a strong nuclear security culture. The provision of modern physical protection, control, and accounting equipment to the Russian Federation alone is not sufficient. Comprehensive infrastructure projects support themore » Russian Federation's ability to maintain the risk reduction achieved through upgrades to the equipment. To illustrate the contributions to security, and challenges of implementation, this paper discusses the history and next steps for an indigenous Tamper Indication Device (TID) program, and a Radiation Portal Monitoring (RPM) program.« less

  16. A Review of Patents for the Smart Packaging of Meat and Muscle-based Food Products.

    PubMed

    Holman, Benjamin; Kerry, Joseph P; Hopkins, David L

    2017-10-31

    Meat packaging once acted primarily as an inert barrier to protect its contents against contamination and this function has shifted. Packaging now includes complementary functions that improve product quality, longevity and customer/retail appeal. The devices and methods applied to achieve these functions may be categorised as smart packaging, which includes intelligent packaging, devised to monitor and communicate packaged content status, and active packaging, to provide passive adjustment of in-pack conditions from its interactions with the packaged meat. Smart packaging examples already available from recent patents include antimicrobial and antioxidant packaging coatings and inserts; sensors or indicators that identify spoilage and freshness; functional engineering customisations; improvements to packaging integrity; leak or tamper detectors; and, environmentally sustainable options. Together, these inventions respond to industry and customer demands for meat packaging and are therefore the focus of this review, in which we discuss their applications and limitations in meat packaging. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  17. Biomolecular detection device

    DOEpatents

    Huo, Qisheng [Albuquerque, NM; Liu, Jun [Albuquerque, NM

    2008-10-21

    A device for detecting and measuring the concentration of biomolecules in solution, utilizing a conducting electrode in contact with a solution containing target biomolecules, with a film with controllable pore size distribution characteristics applied to at least one surface of the conducting electrode. The film is functionalized with probe molecules that chemically interact with the target biomolecules at the film surface, blocking indicator molecules present in solution from diffusing from the solution to the electrode, thereby changing the electrochemical response of the electrode.

  18. Perceptions of transcatheter device closure of patent ductus arteriosus in veterinary cardiology and evaluation of a canine model to simulate device placement: a preliminary study.

    PubMed

    Saunders, A B; Keefe, L; Birch, S A; Wierzbicki, M A; Maitland, D J

    2017-06-01

    The purpose of this study was to evaluate a canine patent ductus arteriosus (PDA) model developed for practicing device placement and to determine practices and perceptions regarding transcatheter closure of PDA from the veterinary cardiology community. A silicone model was developed from images obtained from a dog with a PDA and device placement was performed with catheter equipment and a document camera to simulate fluoroscopy. A total of 36 individuals including 24 diplomates and 12 residents participated, and the feedback was obtained. The study included an initial questionnaire, practice with the model, observation of device placement using the model, and a follow-up questionnaire. A total of 92% of participants including 100% of residents indicated they did not have the opportunity to practice device placement before performing the procedure and obtained knowledge of the procedure from reading journal articles or observation. Participants indicated selecting the appropriate device size (30/36, 83%) and ensuring the device is appropriately positioned before release (18/36, 50%) as the most common areas of difficulty with device placement. Confidence level was higher after practicing with the model for residents when compared with diplomates and for participants that had performed 1-15 procedures when compared with those that had performed >15 procedures. These findings suggest those that have performed fewer procedures may benefit the most from practicing with a model. This preliminary study demonstrates the feasibility of a PDA model for practicing device placement and suggests that there is a potential benefit from providing additional training resources. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Electronic health indicators in the selected countries: Are these indicators the best?

    PubMed Central

    Afshari, Somaye; Khorasani, Elahe; Yarmohammadian, Mohammad Hossein; Atighechian, Golrokh; Darab, Mohsen Ghaffari

    2013-01-01

    Background: Many changes have been made in different sciences by developing and advancing information and communication technology in last two decades. E-health is a very broad term that includes many different activities related to the use of electronic devices, software as well as hardware in health organizations. Aims: The aim of this study is comparing electronic health indicators in the selected countries and discussion on the best indicators. Settings and Design: This study has chosen 12 countries randomly based on the regional division of the WHO. The relevant numbers of health indicators and general indicators and information technology indicators are extracted of these countries. We use data from the Bitarf's comparative study, which is conducted by the Iranian Supreme Council of Information Technology in 2007. Materials and Methods: By using Pearson correlation test, the relations between health general indicators and IT indicators are studied. Statistical Analysis Used: Data was analyzed based on the research objectives using SPSS software and in accordance with research questions Pearson correlation test were used. Results: The findings show that there is a positive relation between indicators related to IT and “Total per capita health, healthy life expectancy, percent literacy”. Furthermore, there is a mutual relation between IT indicators and “mortality indicator”. Conclusion: This study showed differences between selective indicators among different countries. The modern world, with its technological advances, is not powerless in the face of these geographic and health disparity challenges. Researchers must not rely on the available indicators. They must consider indicators like e-business companies, electronic data internet, medical supplies, health electronic record, health information system, etc., In future, continuous studies in this field, to provide the exact and regular reports of amount of using of these indicators through different

  20. Authenticity examination of compressed audio recordings using detection of multiple compression and encoders' identification.

    PubMed

    Korycki, Rafal

    2014-05-01

    Since the appearance of digital audio recordings, audio authentication has been becoming increasingly difficult. The currently available technologies and free editing software allow a forger to cut or paste any single word without audible artifacts. Nowadays, the only method referring to digital audio files commonly approved by forensic experts is the ENF criterion. It consists in fluctuation analysis of the mains frequency induced in electronic circuits of recording devices. Therefore, its effectiveness is strictly dependent on the presence of mains signal in the recording, which is a rare occurrence. Recently, much attention has been paid to authenticity analysis of compressed multimedia files and several solutions were proposed for detection of double compression in both digital video and digital audio. This paper addresses the problem of tampering detection in compressed audio files and discusses new methods that can be used for authenticity analysis of digital recordings. Presented approaches consist in evaluation of statistical features extracted from the MDCT coefficients as well as other parameters that may be obtained from compressed audio files. Calculated feature vectors are used for training selected machine learning algorithms. The detection of multiple compression covers up tampering activities as well as identification of traces of montage in digital audio recordings. To enhance the methods' robustness an encoder identification algorithm was developed and applied based on analysis of inherent parameters of compression. The effectiveness of tampering detection algorithms is tested on a predefined large music database consisting of nearly one million of compressed audio files. The influence of compression algorithms' parameters on the classification performance is discussed, based on the results of the current study. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  1. Portable device for detection of petit mal epilepsy

    NASA Technical Reports Server (NTRS)

    Smith, R. G.; Houge, J. C.; Webster, J. G.

    1979-01-01

    A portable device that analyzes the electroencephalogram to determine if petit mal epilepsy waveforms are present is developed and tested. Clinicians should find it useful in diagnosing seizure activity of their patients. The micropower, battery-operated, portable device indicates a seizure has occurred if three criteria are satisfied: (1) frequencies of 2.5-7 Hz, (2) large-amplitude waves, and (3) minimum number of waves per second. Levels and counts are adjustable, thus insuring high reliability against noise artifacts and permitting each subject to be individually fitted. The device has shown promise in giving the patient a possible mechanism of seizure control or suppression.

  2. Experimental research on a modular miniaturization nanoindentation device

    NASA Astrophysics Data System (ADS)

    Huang, Hu; Zhao, Hongwei; Mi, Jie; Yang, Jie; Wan, Shunguang; Yang, Zhaojun; Yan, Jiwang; Ma, Zhichao; Geng, Chunyang

    2011-09-01

    Nanoindentation technology is developing toward the in situ test which requires miniaturization of indentation instruments. This paper presents a miniaturization nanoindentation device based on the modular idea. It mainly consists of macro-adjusting mechanism, x-y precise positioning platform, z axis precise driving unit, and the load-depth measuring unit. The device can be assembled with different forms and has minimum dimensions of 200 mm × 135 mm × 200 mm. The load resolution is about 0.1 mN and the displacement resolution is about 10 nm. A new calibration method named the reference-mapping method is proposed to calibrate the developed device. Output performance tests and indentation experiments indicate the feasibility of the developed device and calibration method. This paper gives an example that combining piezoelectric actuators with flexure hinge to realize nanoindentation tests. Integrating a smaller displacement sensor, a more compact nanoindentation device can be designed in the future.

  3. Semiconductor diode laser device adjuvanting intradermal vaccine

    PubMed Central

    Kimizuka, Yoshifumi; Callahan, John J.; Huang, Zilong; Morse, Kaitlyn; Katagiri, Wataru; Shigeta, Ayako; Bronson, Roderick; Takeuchi, Shu; Shimaoka, Yusuke; Chan, Megan P. K.; Zeng, Yang; Li, Binghao; Chen, Huabiao; Tan, Rhea Y. Y.; Dwyer, Conor; Mulley, Tyler; Leblanc, Pierre; Goudie, Calum; Gelfand, Jeffrey; Tsukada, Kosuke; Brauns, Timothy; Poznansky, Mark C.; Bean, David; Kashiwagi, Satoshi

    2017-01-01

    A brief exposure of skin to a low-power, non-tissue damaging laser light has been demonstrated to augment immune responses to intradermal vaccination. Both preclinical and clinical studies show that this approach is simple, effective, safe and well tolerated compared to standard chemical or biological adjuvants. Until now, these laser exposures have been performed using a diode-pumped solid-state laser (DPSSL) devices, which are expensive and require labor-intensive maintenance and special training. Development of an inexpensive, easy-to-use and small device would form an important step in translating this technology toward clinical application Here we report that we have established a handheld, near-infrared (NIR) laser device using semiconductor diodes emitting either 1061, 1258, or 1301 nm light that costs less than $4,000, and that this device replicates the adjuvant effect of a DPSSL system in a mouse model of influenza vaccination. Our results also indicate that a broader range of NIR laser wavelengths possess the ability to enhance vaccine immune responses, allowing engineering options for the device design. This small, low-cost device establishes the feasibility of using a laser adjuvant approach for mass-vaccination programs in a clinical setting, opens the door for broader testing of this technology with a variety of vaccines and forms the foundation for development of devices ready for use in the clinic. PMID:28365253

  4. Semiconductor diode laser device adjuvanting intradermal vaccine.

    PubMed

    Kimizuka, Yoshifumi; Callahan, John J; Huang, Zilong; Morse, Kaitlyn; Katagiri, Wataru; Shigeta, Ayako; Bronson, Roderick; Takeuchi, Shu; Shimaoka, Yusuke; Chan, Megan P K; Zeng, Yang; Li, Binghao; Chen, Huabiao; Tan, Rhea Y Y; Dwyer, Conor; Mulley, Tyler; Leblanc, Pierre; Goudie, Calum; Gelfand, Jeffrey; Tsukada, Kosuke; Brauns, Timothy; Poznansky, Mark C; Bean, David; Kashiwagi, Satoshi

    2017-04-25

    A brief exposure of skin to a low-power, non-tissue damaging laser light has been demonstrated to augment immune responses to intradermal vaccination. Both preclinical and clinical studies show that this approach is simple, effective, safe and well tolerated compared to standard chemical or biological adjuvants. Until now, these laser exposures have been performed using a diode-pumped solid-state laser (DPSSL) devices, which are expensive and require labor-intensive maintenance and special training. Development of an inexpensive, easy-to-use and small device would form an important step in translating this technology toward clinical application. Here we report that we have established a handheld, near-infrared (NIR) laser device using semiconductor diodes emitting either 1061, 1258, or 1301nm light that costs less than $4000, and that this device replicates the adjuvant effect of a DPSSL system in a mouse model of influenza vaccination. Our results also indicate that a broader range of NIR laser wavelengths possess the ability to enhance vaccine immune responses, allowing engineering options for the device design. This small, low-cost device establishes the feasibility of using a laser adjuvant approach for mass-vaccination programs in a clinical setting, opens the door for broader testing of this technology with a variety of vaccines and forms the foundation for development of devices ready for use in the clinic. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Photovoltaic device assembly and method

    DOEpatents

    Keenihan, James R.; Langmaid, Joseph A.; Cleereman, Robert J.; Graham, Andrew T.

    2015-09-29

    The present invention is premised upon a connector device and method that can more easily electrically connect a plurality of PV arrays and/or locate these arrays upon a building or structure. It also can optionally provide some additional components (e.g. a bypass diode and/or an indicator means) and can enhance the serviceability of the array.

  6. Device-identified atrial fibrillation at pacing clinics. Should it guide anticoagulation?

    PubMed

    Merinopoulos, Ioannis; Raphael, Claire E; Yardley, Alaina; Goonewardene, Manoj; Vassiliou, Vassilios S

    2016-03-15

    In recent years, there has been a significant increase in the number of devices implanted following improvement in their safety profile, extension of indications and reduction in cost. Although the reason remains largely the beneficial effect on heart rhythm stabilisation, implanted devices might also have additional advantages, notably identification of silent arrhythmia. Should clinicians therefore act on device-identified atrial fibrillation (AF) and should such identification be used to guide anticoagulation management? This review evaluates the current evidence on the management of device-identified asymptomatic AF. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. USB Storage Device Forensics for Windows 10.

    PubMed

    Arshad, Ayesha; Iqbal, Waseem; Abbas, Haider

    2018-05-01

    Significantly increased use of USB devices due to their user-friendliness and large storage capacities poses various threats for many users/companies in terms of data theft that becomes easier due to their efficient mobility. Investigations for such data theft activities would require gathering critical digital information capable of recovering digital forensics artifacts like date, time, and device information. This research gathers three sets of registry and logs data: first, before insertion; second, during insertion; and the third, after removal of a USB device. These sets are analyzed to gather evidentiary information from Registry and Windows Event log that helps in tracking a USB device. This research furthers the prior research on earlier versions of Microsoft Windows and compares it with latest Windows 10 system. Comparison of Windows 8 and Windows 10 does not show much difference except for new subkey under USB Key in registry. However, comparison of Windows 7 with latest version indicates significant variances. © 2017 American Academy of Forensic Sciences.

  8. 16 CFR 1507.9 - Toy smoke devices and flitter devices.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Toy smoke devices and flitter devices. 1507... SUBSTANCES ACT REGULATIONS FIREWORKS DEVICES § 1507.9 Toy smoke devices and flitter devices. (a) Toy smoke... fuse and firstfire upon ignition) during normal operation. (b) Toy smoke devices and flitter devices...

  9. 16 CFR 1507.9 - Toy smoke devices and flitter devices.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Toy smoke devices and flitter devices. 1507... SUBSTANCES ACT REGULATIONS FIREWORKS DEVICES § 1507.9 Toy smoke devices and flitter devices. (a) Toy smoke... fuse and firstfire upon ignition) during normal operation. (b) Toy smoke devices and flitter devices...

  10. 16 CFR 1507.9 - Toy smoke devices and flitter devices.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Toy smoke devices and flitter devices. 1507... SUBSTANCES ACT REGULATIONS FIREWORKS DEVICES § 1507.9 Toy smoke devices and flitter devices. (a) Toy smoke... fuse and firstfire upon ignition) during normal operation. (b) Toy smoke devices and flitter devices...

  11. Implosion-driven technique to create fast shockwaves in high-density gas

    NASA Astrophysics Data System (ADS)

    Serge, Matthew; Loiseau, Jason; Huneault, Justin; Szirti, Daniel; Higgins, Andrew; Tanguay, Vincent

    2012-03-01

    Pressurized tubes surrounded by either one or two layers (separated by a secondary tube) of sensitized nitromethane and encased in a thick-walled tube (the tamper) were imploded. The distance between the detonation wave in the explosive and shock wave in the innermost tube were measured (the standoff). A simple model based on hoop stress and acoustic interactions between the tubing was developed and used to predict the standoff distance. At low initial pressures (on the order of 7MPa), results indicate that the secondary tube and two layers of explosive did not prove to significantly increase the standoff. However, at higher pressures (on the order of 10 MPa), standoff was noticeably greater when the secondary tube was inserted between the pressurized tube and the tamper. The measured values are in reasonable agreement with the predictions of the model.

  12. The lasting legacy of war: epidemiology of injuries from landmines and unexploded ordnance in Afghanistan, 2002-2006.

    PubMed

    Bilukha, Oleg O; Brennan, Muireann; Anderson, Mark

    2008-01-01

    Due to several decades of armed conflict and civil unrest, Afghanistan is one of the countries most affected by landmines and unexploded ordnance worldwide. The study was performed to assess the magnitude of injuries due to landmines and unexploded ordnance in Afghanistan during 2002-2006 and to describe epidemiological patterns and potential risk factors for these events. Surveillance data including 5,471 injuries caused by landmines and unexploded ordnance in Afghanistan during 2002-2006 were analyzed. The International Committee of the Red Cross collects data on such injuries from 490 reporting health facilities and volunteers throughout the country. These surveillance data were used to describe injury trends, victim demographics, injury types, risk behaviors, and explosive types related to landmine and unexploded ordnance accidents. The largest number of injuries (1,706) occurred in 2002. The number declined sharply to 1,049 injuries in 2003, and remained relatively stable with slight decline thereafter. Overall, 92% of victims were civilians, 91% were males, and 47% were children <18 years of age. The case-fatality ratio was 17%. Approximately 50% of all injuries were caused by unexploded ordnance and 42% by landmines. Among children, 65% of injuries were caused by unexploded ordnance and only 27% by landmines, whereas in adults, most injuries (56%) were caused by landmines. The most common risk behaviors among children were tending animals, playing, and tampering with explosive devices. In adults, most common risk behaviors were traveling, performing activities of economic necessity, and tampering with explosives. Twenty-eight percent of the surviving victims who received mine awareness training and 2% of those who did not receive such training reported that the area where event occurred was marked. The large number of injuries and high proportion of child victims suggest that clearance and risk education activities fall short of achieving their goals, and

  13. Radiation effects on MOS devices - dosimetry, annealing, irradiation sequence, and sources

    NASA Technical Reports Server (NTRS)

    Stassinopoulos, E. G.; Brucker, G. J.; Van Gunten, O.; Knudson, A. R.; Jordan, T. M.

    1983-01-01

    This paper reports on some investigations of dosimetry, annealing, irradiation sequences, and radioactive sources, involved in the determination of radiation effects on MOS devices. Results show that agreement in the experimental and theoretical surface to average doses support the use of thermo-luminescent dosimeters (manganese activated calcium fluoride) in specifying the surface dose delivered to thin gate insulators of MOS devices. Annealing measurements indicate the existence of at least two energy levels,,s or a activation energies, for recovery of soft oxide MOS devices after irradiation by electrons, protons, and gammas. Damage sensitivities of MOS devices were found to be independent of combinations and sequences of radiation type or energies. Comparison of various gamma sources indicated a small dependence of damage sensitivity on the Cobalt facility, but a more significant dependence in the case of the Cesium source. These results were attributed to differences in the spectral content of the several sources.

  14. Graphene device and method of using graphene device

    DOEpatents

    Bouchiat, Vincent; Girit, Caglar; Kessler, Brian; Zettl, Alexander K.

    2015-08-11

    An embodiment of a graphene device includes a layered structure, first and second electrodes, and a dopant island. The layered structure includes a conductive layer, an insulating layer, and a graphene layer. The electrodes are coupled to the graphene layer. The dopant island is coupled to an exposed surface of the graphene layer between the electrodes. An embodiment of a method of using a graphene device includes providing the graphene device. A voltage is applied to the conductive layer of the graphene device. Another embodiment of a method of using a graphene device includes providing the graphene device without the dopant island. A dopant island is placed on an exposed surface of the graphene layer between the electrodes. A voltage is applied to the conductive layer of the graphene device. A response of the dopant island to the voltage is observed.

  15. A portable device for calibration of autocollimators with nanoradian precision

    NASA Astrophysics Data System (ADS)

    Yandayan, Tanfer

    2017-09-01

    A portable device has been developed in TUBITAK UME to calibrate high precision autocollimators with nanoradian precision. The device can operate in the range of +/-4500" which is far enough for the calibration of the available autocollimators and can generate ultra-small angles in measurement steps of 0.0005" (2.5 nrad). Description of the device with the performance tests using the calibrated precise autocollimators and novel methods will be reported. The test results indicate that the device is a good candidate for application to on-site/in-situ calibration of autocollimators with expanded uncertainties of 0.01" (50 nrad) particularly those used in slope measuring profilers.

  16. Implantable cardioverter-defibrillator implantation for primary and secondary prevention: indications and outcomes.

    PubMed

    Pick, Justin M; Batra, Anjan S

    2017-01-01

    Implantable cardioverter-defibrillators effectively reduce the rate of sudden cardiac death in children. Significant efforts have been made to better characterise the indications for their placement, and over the past two decades there has been a shift in their use from secondary to primary prevention. Primary prevention includes placement in patients thought to be at high risk of sudden cardiac death before the patient experiences any event. Secondary prevention includes placement after a high-risk event including sustained ventricular tachycardia or resuscitated cardiac arrest. Although liberal device implantation may be appealing even in patients having marginal indications, studies have shown high rates of adverse effects including inappropriate device discharges and the need for re-intervention because of hardware malfunction. The indications for placement of an implantable cardioverter-defibrillator, whether for primary or secondary prevention of sudden cardiac death, vary based on cardiac pathology. This review will assist the provider in understanding the risks and benefits of device implantation in order to enhance the shared decision-making capacity of patients, families, and providers.

  17. Borehole sounding device with sealed depth and water level sensors

    DOEpatents

    Skalski, Joseph C.; Henke, Michael D.

    2005-08-02

    A borehole device having proximal and distal ends comprises an enclosure at the proximal end for accepting an aircraft cable containing a plurality of insulated conductors from a remote position. A water sensing enclosure is sealingly attached to the enclosure and contains means for detecting water, and sending a signal on the cable to the remote position indicating water has been detected. A bottom sensing enclosure is sealingly attached to the water sensing enclosure for determining when the borehole device encounters borehole bottom and sends a signal on the cable to the remote position indicating that borehole bottom has been encountered.

  18. Progesterone-releasing devices for cattle estrus induction and synchronization: Device optimization to anticipate shorter treatment durations and new device developments.

    PubMed

    de Graaff, W; Grimard, B

    2018-05-01

    Synchronization programs using progesterone-releasing intravaginal devices that allow for fixed time artificial insemination are still finding increasing application in bovine reproduction. This practice is useful for rationalizing livestock management because an increased number of cows can be inseminated in one session without the need for estrus detection. Although much of the innovation related to the design and development of intravaginal devices for use in cattle took place in the previous century, progress in understanding the physiology of the bovine estrous cycle resulted in shorter treatment durations, a trend which is still continuing. In this competitive market, with little functional differentiation between the existing devices, the shorter treatment duration prompted for optimization of the progesterone content in the device, as the cost of the drug significantly contributes to the price per unit. For CIDR ® a reduction of the progesterone content of about 30 per cent was realized. Price reduction remained an important target for further device development. Next to reduction of progesterone content, cheaper and easier to process materials like polyethylene vinyl acetate (EVA) copolymers have been explored to replace the commonly used silicone elastomers. The reengineering effort of CIDR ® demonstrated that knowledge of release kinetics and insight into gradual depletion patterns in the device is critical for optimization of drug content without compromising performance (blood levels). More recent publications related to the use of alternative polymers like EVA and polyisoprene (IP) indicated encouraging results regarding further reduction of progesterone content. The use of EVA seems most promising, because it is in principle a low-cost polymer available in many grades and this thermoplastic polymer can be processed easily by means of commonly used techniques like injection molding and extrusion. The use of thermoplastic polymers, however, requires

  19. Spent fuel container alignment device and method

    DOEpatents

    Jones, Stewart D.; Chapek, George V.

    1996-01-01

    An alignment device is used with a spent fuel shipping container including a plurality of fuel pockets for spent fuel arranged in an annular array and having a rotatable cover including an access opening therein. The alignment device includes a lightweight plate which is installed over the access opening of the cover. A laser device is mounted on the plate so as to emit a laser beam through a laser admittance window in the cover into the container in the direction of a pre-established target associated with a particular fuel pocket. An indexing arrangement on the container provides an indication of the angular position of the rotatable cover when the laser beam produced by the laser is brought into alignment with the target of the associated fuel pocket.

  20. Development of an Optical Device to Investigatechlorophyll Content of Tomato Leaves

    NASA Astrophysics Data System (ADS)

    Cui, Di; Li, Minzan; Li, Xiuhua

    Chlorophyll content is an important indication for evaluating crop growth status and predicting crop yield. The NDVI (Normalized Difference Vegetation Index) is commonly used as an indicator in practical crop healthy monitoring. Hence, a spectroscopy-based device for indirectly measuring crop growth conditions in terms of NDVI is developed. This device consists of four channels: two are designed to measure the intensity of the sunlight and the other two are used to measure the reflected light from the crop canopy at the same time. An electronic control unit was designed to control the sensing and data recording processes, as well as to calculate the NDVI based on the sensed data. The measurable two wavelengths are 610 nm and 1220 nm. A series validation tests, comparing the measurement result against spectroradiometer readings, are conducted to evaluate the performance of the device. Leaf samples are collected to measure chlorophyll contents in laboratory. The correlation coefficient between the NDVI readings from the developed device and the chlorophyll content data measured by the UV-VIS Spectrophotometer reaches 0.81, which shows that the device can be used in practical crop management.

  1. Crosstalk compensation in analysis of energy storage devices

    DOEpatents

    Christophersen, Jon P; Morrison, John L; Morrison, William H; Motloch, Chester G; Rose, David M

    2014-06-24

    Estimating impedance of energy storage devices includes generating input signals at various frequencies with a frequency step factor therebetween. An excitation time record (ETR) is generated to include a summation of the input signals and a deviation matrix of coefficients is generated relative to the excitation time record to determine crosstalk between the input signals. An energy storage device is stimulated with the ETR and simultaneously a response time record (RTR) is captured that is indicative of a response of the energy storage device to the ETR. The deviation matrix is applied to the RTR to determine an in-phase component and a quadrature component of an impedance of the energy storage device at each of the different frequencies with the crosstalk between the input signals substantially removed. This approach enables rapid impedance spectra measurements that can be completed within one period of the lowest frequency or less.

  2. Electronic medical devices: a primer for pathologists.

    PubMed

    Weitzman, James B

    2003-07-01

    Electronic medical devices (EMDs) with downloadable memories, such as implantable cardiac pacemakers, defibrillators, drug pumps, insulin pumps, and glucose monitors, are now an integral part of routine medical practice in the United States, and functional organ replacements, such as the artificial heart, pancreas, and retina, will most likely become commonplace in the near future. Often, EMDs end up in the hands of the pathologist as a surgical specimen or at autopsy. No established guidelines for systematic examination and reporting or comprehensive reviews of EMDs currently exist for the pathologist. To provide pathologists with a general overview of EMDs, including a brief history; epidemiology; essential technical aspects, indications, contraindications, and complications of selected devices; potential applications in pathology; relevant government regulations; and suggested examination and reporting guidelines. Articles indexed on PubMed of the National Library of Medicine, various medical and history of medicine textbooks, US Food and Drug Administration publications and product information, and specifications provided by device manufacturers. Studies were selected on the basis of relevance to the study objectives. Descriptive data were selected by the author. Suggested examination and reporting guidelines for EMDs received as surgical specimens and retrieved at autopsy. Electronic medical devices received as surgical specimens and retrieved at autopsy are increasing in number and level of sophistication. They should be systematically examined and reported, should have electronic memories downloaded when indicated, will help pathologists answer more questions with greater certainty, and should become an integral part of the formal knowledge base, research focus, training, and practice of pathology.

  3. 30 CFR 75.1001-1 - Devices for overcurrent protection; testing and calibration requirements; records.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Devices for overcurrent protection; testing and... Trolley Wires and Trolley Feeder Wires § 75.1001-1 Devices for overcurrent protection; testing and.... Calibration of such devices shall include adjustment of all associated relays to ±15 percent of the indicated...

  4. 30 CFR 75.1001-1 - Devices for overcurrent protection; testing and calibration requirements; records.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Devices for overcurrent protection; testing and... Trolley Wires and Trolley Feeder Wires § 75.1001-1 Devices for overcurrent protection; testing and.... Calibration of such devices shall include adjustment of all associated relays to ±15 percent of the indicated...

  5. 16 CFR § 1507.9 - Toy smoke devices and flitter devices.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Toy smoke devices and flitter devices. Â... SUBSTANCES ACT REGULATIONS FIREWORKS DEVICES § 1507.9 Toy smoke devices and flitter devices. (a) Toy smoke... fuse and firstfire upon ignition) during normal operation. (b) Toy smoke devices and flitter devices...

  6. 78 FR 79300 - Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems for Acute...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-30

    ... balloon and control system (IABP) devices when indicated for acute coronary syndrome, cardiac and non... and non-cardiac surgery, or complications of heart failure. The special controls for this device are.... FDA-2013-N-0581] Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems...

  7. Simple Check Valves for Microfluidic Devices

    NASA Technical Reports Server (NTRS)

    Willis, Peter A.; Greer, Harold F.; Smith, J. Anthony

    2010-01-01

    A simple design concept for check valves has been adopted for microfluidic devices that consist mostly of (1) deformable fluorocarbon polymer membranes sandwiched between (2) borosilicate float glass wafers into which channels, valve seats, and holes have been etched. The first microfluidic devices in which these check valves are intended to be used are micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. In this application, it will be necessary to store some liquid samples in reservoirs in the devices for subsequent laboratory analysis, and check valves are needed to prevent cross-contamination of the samples. The simple check-valve design concept is also applicable to other microfluidic devices and to fluidic devices in general. These check valves are simplified microscopic versions of conventional rubber- flap check valves that are parts of numerous industrial and consumer products. These check valves are fabricated, not as separate components, but as integral parts of microfluidic devices. A check valve according to this concept consists of suitably shaped portions of a deformable membrane and the two glass wafers between which the membrane is sandwiched (see figure). The valve flap is formed by making an approximately semicircular cut in the membrane. The flap is centered over a hole in the lower glass wafer, through which hole the liquid in question is intended to flow upward into a wider hole, channel, or reservoir in the upper glass wafer. The radius of the cut exceeds the radius of the hole by an amount large enough to prevent settling of the flap into the hole. As in a conventional rubber-flap check valve, back pressure in the liquid pushes the flap against the valve seat (in this case, the valve seat is the adjacent surface of the lower glass wafer), thereby forming a seal that prevents backflow.

  8. Photonic variable delay devices based on optical birefringence

    NASA Technical Reports Server (NTRS)

    Yao, X. Steve (Inventor)

    2005-01-01

    Optical variable delay devices for providing variable true time delay to multiple optical beams simultaneously. A ladder-structured variable delay device comprises multiple basic building blocks stacked on top of each other resembling a ladder. Each basic building block has two polarization beamsplitters and a polarization rotator array arranged to form a trihedron; Controlling an array element of the polarization rotator array causes a beam passing through the array element either going up to a basic building block above it or reflect back towards a block below it. The beams going higher on the ladder experience longer optical path delay. An index-switched optical variable delay device comprises of many birefringent crystal segments connected with one another, with a polarization rotator array sandwiched between any two adjacent crystal segments. An array element in the polarization rotator array controls the polarization state of a beam passing through the element, causing the beam experience different refractive indices or path delays in the following crystal segment. By independently control each element in each polarization rotator array, variable optical path delays of each beam can be achieved. Finally, an index-switched variable delay device and a ladder-structured variable device are cascaded to form a new device which combines the advantages of the two individual devices. This programmable optic device has the properties of high packing density, low loss, easy fabrication, and virtually infinite bandwidth. The device is inherently two dimensional and has a packing density exceeding 25 lines/cm2. The delay resolution of the device is on the order of a femtosecond (one micron in space) and the total delay exceeds 10 nanosecond. In addition, the delay is reversible so that the same delay device can be used for both antenna transmitting and receiving.

  9. CVD Polymers for Devices and Device Fabrication.

    PubMed

    Wang, Minghui; Wang, Xiaoxue; Moni, Priya; Liu, Andong; Kim, Do Han; Jo, Won Jun; Sojoudi, Hossein; Gleason, Karen K

    2017-03-01

    Chemical vapor deposition (CVD) polymerization directly synthesizes organic thin films on a substrate from vapor phase reactants. Dielectric, semiconducting, electrically conducting, and ionically conducting CVD polymers have all been readily integrated into devices. The absence of solvent in the CVD process enables the growth of high-purity layers and avoids the potential of dewetting phenomena, which lead to pinhole defects. By limiting contaminants and defects, ultrathin (<10 nm) CVD polymeric device layers have been fabricated in multiple laboratories. The CVD method is particularly suitable for synthesizing insoluble conductive polymers, layers with high densities of organic functional groups, and robust crosslinked networks. Additionally, CVD polymers are prized for the ability to conformally cover rough surfaces, like those of paper and textile substrates, as well as the complex geometries of micro- and nanostructured devices. By employing low processing temperatures, CVD polymerization avoids damaging substrates and underlying device layers. This report discusses the mechanisms of the major CVD polymerization techniques and the recent progress of their applications in devices and device fabrication, with emphasis on initiated CVD (iCVD) and oxidative CVD (oCVD) polymerization. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Wireless device monitoring systems and monitoring devices, and associated methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCown, Steven H; Derr, Kurt W; Rohde, Kenneth W

    Wireless device monitoring systems and monitoring devices include a communications module for receiving wireless communications of a wireless device. Processing circuitry is coupled with the communications module and configured to process the wireless communications to determine whether the wireless device is authorized or unauthorized to be present at the monitored area based on identification information of the wireless device. Methods of monitoring for the presence and identity of wireless devices are also provided.

  11. Molecular materials for high performance OPV devices (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Jones, David J.

    2016-09-01

    We recently reported the high performing molecular donor for OPV devices based on a benzodithiophene core, a terthiophene bridge and a rhodamine acceptor (BTR) [1]. In this work we optimized side-chain placement of a known chromophore by ensuring the thiophene hexyl side-chains are regioregular, which should allow the chromophore to lie flat. The unexpected outcome was a nematic liquid crystalline material with significantly improved performance (now 9.6% PCE), excellent charge transport properties, reduced geminate recombination rates and excellent performance with active layers up to 400nm. Three phase changes were indicated by DSC analysis with a melt to a crystalline domain at 175 oC, transition to a nematic liquid crystalline domain at 186 oC and an isotropic melt at 196 oC. In our desire to better understand the structure property relationships of this class of p-type organic semiconductor we have synthesized a series of analogues where the length of the chromophore has been altered through modification of the oligothiophene bridge to generate, the monothiophene (BMR), the bisthiophene (BBR), the known terthiophene (BTR), the quaterthiophene (BQR) and the pentathiophene (BPR). BMR, BBR and BPR have clean melting points while BQR, like BTR shows a complicated series of phase transitions. Device efficiencies after solvent vapour annealing are BMR (3.5%), BBR (6.0%), BTR (9.3%), BQR (9.4%), and BPR (8.7%) unoptimised. OPV devices with BTR in the active layer are not stable under thermal annealing, however the bridge extended BQR and BPR form thermally stable devices. We are currently optimising these devices, but initial results indicate PCEs >9% for thermally annealed devices containing BQR, while BPR devices have not yet been optimised and have PCEs > 8%. In order to develop the device performance we have included BQR in ternary devices with the commercially available PTB7-Th and we report device efficiencies of over 10.5%. We are currently optimising device

  12. Management of Patients With Cardiovascular Implantable Electronic Devices in Dental, Oral, and Maxillofacial Surgery.

    PubMed

    Tom, James

    2016-01-01

    The prevalence of cardiovascular implantable electronic devices as life-prolonging and life-saving devices has evolved from a treatment of last resort to a first-line therapy for an increasing number of patients. As these devices become more and more popular in the general population, dental providers utilizing instruments and medications should be aware of dental equipment and medications that may affect these devices and understand the management of patients with these devices. This review article will discuss the various types and indications for pacemakers and implantable cardioverter-defibrillators, common drugs and instruments affecting these devices, and management of patients with these devices implanted for cardiac dysrhythmias.

  13. Management of Patients With Cardiovascular Implantable Electronic Devices in Dental, Oral, and Maxillofacial Surgery

    PubMed Central

    Tom, James

    2016-01-01

    The prevalence of cardiovascular implantable electronic devices as life-prolonging and life-saving devices has evolved from a treatment of last resort to a first-line therapy for an increasing number of patients. As these devices become more and more popular in the general population, dental providers utilizing instruments and medications should be aware of dental equipment and medications that may affect these devices and understand the management of patients with these devices. This review article will discuss the various types and indications for pacemakers and implantable cardioverter-defibrillators, common drugs and instruments affecting these devices, and management of patients with these devices implanted for cardiac dysrhythmias. PMID:27269668

  14. Operating manual-based usability evaluation of medical devices: an effective patient safety screening method.

    PubMed

    Turley, James P; Johnson, Todd R; Smith, Danielle Paige; Zhang, Jaijie; Brixey, Juliana J

    2006-04-01

    Use of medical devices often directly contributes to medical errors. Because it is difficult or impossible to change the design of existing devices, the best opportunity for improving medical device safety is during the purchasing process. However, most hospital personnel are not familiar with the usability evaluation methods designed to identify aspects of a user interface that do not support intuitive and safe use. A review of medical device operating manuals is proposed as a more practical method of usability evaluation. Operating manuals for five volumetric infusion pumps from three manufacturers were selected for this study (January-April 2003). Each manual's safety message content was evaluated to determine whether the message indicated a device design characteristic that violated known usability principles (heuristics) or indicated a violation of an affordance of the device. "Minimize memory load," with 65 violations, was the heuristic violated most frequently across pumps. Variations between pumps, including the frequency and severity of violations for each, were noted. Results suggest that manual review can provide a proxy for heuristic evaluation of the actual medical device. This method, intended to be a component of prepurchasing evaluation, can complement more formal usability evaluation methods and be used to select a subset of devices for more extensive and formal testing.

  15. Fiber optic monitoring device

    DOEpatents

    Samborsky, James K.

    1993-01-01

    A device for the purpose of monitoring light transmissions in optical fibers comprises a fiber optic tap that optically diverts a fraction of a transmitted optical signal without disrupting the integrity of the signal. The diverted signal is carried, preferably by the fiber optic tap, to a lens or lens system that disperses the light over a solid angle that facilitates viewing. The dispersed light indicates whether or not the monitored optical fiber or system of optical fibers is currently transmitting optical information.

  16. Single-use device reuse risks.

    PubMed

    Lee, Robert C; Berzins, Sandy; Alfieri, Nancy

    2007-01-01

    Efforts to reduce both costs and medical waste have led many health systems to start reusing single-use medical devices (SUDs) after cleaning and sterilizing (i.e. reprocessing). There is a currently a wide range of SUD types being reused in many health systems. The objective of this paper is to provide a brief summary of risk issues associated with critical SUDs, based on a rapid review of the available literature. The specific focus is on risk issues, but includes discussion of economic and legal/ethical issues as well. The evidence in the literature regarding the safety of reuse of SUDs indicates that for certain devices (e.g. heart catheters) reuse can be safe (in terms of patient infection) and cost-effective as long as stringent reprocessing protocols are followed. However, potential risks associated with reusing SUDs are not just limited to infection of patients. There are staff and environmental risks, plus important legal, ethical, and financial issues to consider in a reuse policy. There are currently no Canadian guidelines on reuse or reprocessing SUDs, although a national Scientific Advisory Panel on Reprocessing of Medical Devices has made recommendations. Additionally, reuse of SUDs is interwoven with the issue of infection control and reprocessing procedures in general and as applied to multiple-use devices. With limited healthcare resources, there will always be a trade-off between the human resources and costs required to clean and sterilize reused devices with costs associated with purchasing and disposing of non-reused SUDs. Evaluation of complete operational pathways, especially for more expensive and commonly used SUDs, will be useful to properly determine the balance of benefits, risks, and costs under a reuse policy.

  17. Patient- and Technician-Oriented Attitudes Toward Transcranial Magnetic Stimulation Devices.

    PubMed

    Lonergan, Brady; Nguyen, Eliza; Lembo, Cara; Hinchman, Carrie; Morales, Oscar G; Press, Daniel Z; Pascual-Leone, Alvaro; Stern, Adam P

    2018-01-25

    Four transcranial magnetic stimulation (TMS) devices are currently approved for use in treatment-resistant depression. The authors present the first data-driven study examining the patient- and technician-experience using three of these distinct devices. A retrospective survey design with both patient and technician arms was utilized. The study population included patients who received TMS for treatment-resistant depression at the Berenson Allen Center for Noninvasive Brain Stimulation for the first time between 2013 and 2016 and technicians who worked in the program from 2009 to 2017. Statistical analysis included t tests and analyses of variance to assess differences between and across the multiple groups, respectively. Patients treated with the NeuroStar device reported greater confidence that the treatment was being performed correctly compared with those treated with the Magstim device. Conversely, with regard to tolerability, patients treated with the Magstim device reported less pain in the last week and less pain on average compared with those treated with the NeuroStar device. On average, technicians reported feeling that both the Magstim and NeuroStar devices were significantly easier to use than the Brainsway Deep TMS H-Coil device. Additionally, they found the former two devices to be more reliable and better tolerated. Furthermore, the technicians reported greater confidence in the Magstim and NeuroStar devices compared with the Brainsway Deep TMS H-Coil device and indicated that they would be more likely to recommend the two former devices to other treatment centers.

  18. CONTROL LIMITER DEVICE

    DOEpatents

    DeShong, J.A.

    1960-03-01

    A control-limiting device for monltoring a control system is described. The system comprises a conditionsensing device, a condition-varying device exerting a control over the condition, and a control means to actuate the condition-varying device. A control-limiting device integrates the total movement or other change of the condition-varying device over any interval of time during a continuum of overlapping periods of time, and if the tothl movement or change of the condition-varying device exceeds a preset value, the control- limiting device will switch the control of the operated apparatus from automatic to manual control.

  19. Challenges faced in long term ventricular assist device support.

    PubMed

    Ikegami, Hirohisa; Kurlansky, Paul; Takeda, Koji; Naka, Yoshifumi

    2016-08-01

    The development of ventricular assist device (VAD) has been one of the revolutionary advancements in end-stage heart failure management. Although the device has developed and improved significantly over the last few decades, we still face multiple challenges. This review will discuss quality of life, survival, and clinically encountered complications in patients with VAD support. The literature was extensively reviewed for studies describing the above topic area. We describe the impact of major challenges faced in VAD support and discuss their future and expectations. Expert commentary: The technological advancement of VADs has contributed to major improvement of overall survival, enhancement of quality of life and decrease of incidence of complications. It is expected that technologies will continue to evolve. At the same time, the indications for and timing of device implantation, and selection of device type are continuously important in clinical practice setting.

  20. Portable Wireless Device Threat Assessment for Aircraft Navigation Radios

    NASA Technical Reports Server (NTRS)

    Nguyen, Truong X.; Koppen, Sandra V.; Ely, Jay J.; Williams, Reuben A.; Smith, Laura J.; Salud, Maria Theresa P.

    2004-01-01

    This paper addresses the concern for Wireless Local Area Network devices and two-way radios to cause electromagnetic interference to aircraft navigation radio systems. Spurious radiated emissions from various IEEE 802.11a, 802.11b, and Bluetooth devices are characterized using reverberation chambers. The results are compared with baseline emissions from standard laptop computer and personal digital assistants (PDAs) that are currently allowed for use on aircraft. The results indicate that the WLAN devices tested are not more of a threat to aircraft navigation radios than standard laptop computers and PDAs in most aircraft bands. In addition, spurious radiated emission data from seven pairs of two-way radios are provided. These two-way radios emit at much higher levels in the bands considered. A description of the measurement process, device modes of operation and the measurement results are reported.

  1. Mobile Devices to Bridge the Gap in VET: Ease of Use and Usefulness as Indicators for Their Acceptance

    ERIC Educational Resources Information Center

    Motta, Elisa; Cattaneo, Alberto; Gurtner, Jean-Luc

    2014-01-01

    In the dual-track Vocational Education and Training (VET) system, apprentices gain experiences in different learning locations (i.e. workplace and school) but the bridges between these experiences are difficult to construct. Mobile devices could help to promote connectivity across learning contexts, provided they are accepted by the various…

  2. Release strategies for making transferable semiconductor structures, devices and device components

    DOEpatents

    Rogers, John A; Nuzzo, Ralph G; Meitl, Matthew; Ko, Heung Cho; Yoon, Jongseung; Menard, Etienne; Baca, Alfred J

    2014-11-25

    Provided are methods for making a device or device component by providing a multilayer structure having a plurality of functional layers and a plurality of release layers and releasing the functional layers from the multilayer structure by separating one or more of the release layers to generate a plurality of transferable structures. The transferable structures are printed onto a device substrate or device component supported by a device substrate. The methods and systems provide means for making high-quality and low-cost photovoltaic devices, transferable semiconductor structures, (opto-)electronic devices and device components.

  3. Release strategies for making transferable semiconductor structures, devices and device components

    DOEpatents

    Rogers, John A [Champaign, IL; Nuzzo, Ralph G [Champaign, IL; Meitl, Matthew [Raleigh, NC; Ko, Heung Cho [Urbana, IL; Yoon, Jongseung [Urbana, IL; Menard, Etienne [Durham, NC; Baca, Alfred J [Urbana, IL

    2011-04-26

    Provided are methods for making a device or device component by providing a multilayer structure having a plurality of functional layers and a plurality of release layers and releasing the functional layers from the multilayer structure by separating one or more of the release layers to generate a plurality of transferable structures. The transferable structures are printed onto a device substrate or device component supported by a device substrate. The methods and systems provide means for making high-quality and low-cost photovoltaic devices, transferable semiconductor structures, (opto-)electronic devices and device components.

  4. Release strategies for making transferable semiconductor structures, devices and device components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rogers, John A.; Nuzzo, Ralph G.; Meitl, Matthew

    2016-05-24

    Provided are methods for making a device or device component by providing a multi layer structure having a plurality of functional layers and a plurality of release layers and releasing the functional layers from the multilayer structure by separating one or more of the release layers to generate a plurality of transferable structures. The transferable structures are printed onto a device substrate or device component supported by a device substrate. The methods and systems provide means for making high-quality and low-cost photovoltaic devices, transferable semiconductor structures, (opto-)electronic devices and device components.

  5. Detection and response to unauthorized access to a communication device

    DOEpatents

    Smith, Rhett; Gordon, Colin

    2015-09-08

    A communication gateway consistent with the present disclosure may detect unauthorized physical or electronic access and implement security actions in response thereto. A communication gateway may provide a communication path to an intelligent electronic device (IED) using an IED communications port configured to communicate with the IED. The communication gateway may include a physical intrusion detection port and a network port. The communication gateway may further include control logic configured to evaluate physical intrusion detection signal. The control logic may be configured to determine that the physical intrusion detection signal is indicative of an attempt to obtain unauthorized access to one of the communication gateway, the IED, and a device in communication with the gateway; and take a security action based upon the determination that the indication is indicative of the attempt to gain unauthorized access.

  6. 21 CFR 864.9195 - Blood mixing devices and blood weighing devices.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood mixing devices and blood weighing devices... Manufacture Blood and Blood Products § 864.9195 Blood mixing devices and blood weighing devices. (a) Identification. A blood mixing device is a device intended for medical purposes that is used to mix blood or...

  7. 21 CFR 864.9195 - Blood mixing devices and blood weighing devices.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood mixing devices and blood weighing devices... Manufacture Blood and Blood Products § 864.9195 Blood mixing devices and blood weighing devices. (a) Identification. A blood mixing device is a device intended for medical purposes that is used to mix blood or...

  8. 21 CFR 864.9195 - Blood mixing devices and blood weighing devices.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood mixing devices and blood weighing devices... Manufacture Blood and Blood Products § 864.9195 Blood mixing devices and blood weighing devices. (a) Identification. A blood mixing device is a device intended for medical purposes that is used to mix blood or...

  9. 21 CFR 864.9195 - Blood mixing devices and blood weighing devices.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood mixing devices and blood weighing devices... Manufacture Blood and Blood Products § 864.9195 Blood mixing devices and blood weighing devices. (a) Identification. A blood mixing device is a device intended for medical purposes that is used to mix blood or...

  10. 21 CFR 864.9195 - Blood mixing devices and blood weighing devices.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood mixing devices and blood weighing devices... Manufacture Blood and Blood Products § 864.9195 Blood mixing devices and blood weighing devices. (a) Identification. A blood mixing device is a device intended for medical purposes that is used to mix blood or...

  11. Home oxygen therapy: re-thinking the role of devices.

    PubMed

    Melani, Andrea S; Sestini, Piersante; Rottoli, Paola

    2018-03-01

    A range of devices are available for delivering and monitoring home oxygen therapy (HOT). Guidelines do not give indications for the choice of the delivery device but recommend the use of an ambulatory system in subjects on HOT whilst walking. Areas covered: We provide a clinical overview of HOT and review traditional and newer delivery and monitoring devices for HOT. Despite relevant technology advancements, clinicians, faced with many challenges when they prescribe oxygen therapy, often remain familiar to traditional devices and continuous flow delivery of oxygen. Some self-filling delivery-less devices could increase the users' level of independence with ecological advantage and, perhaps, reduced cost. Some newer portable oxygen concentrators are being available, but more work is needed to understand their performances in different diseases and clinical settings. Pulse oximetry has gained large diffusion worldwide and some models permit long-term monitoring. Some closed-loop portable monitoring devices are also able to adjust oxygen flow automatically in accordance with the different needs of everyday life. This might help to improve adherence and the practice of proper oxygen titration that has often been omitted because difficult to perform and time-consuming. Expert commentary: The prescribing physicians should know the characteristics of newer devices and use technological advancements to improve the practice of HOT.

  12. A Novel Wireless Wearable Volatile Organic Compound (VOC) Monitoring Device with Disposable Sensors.

    PubMed

    Deng, Yue; Chen, Cheng; Xian, Xiaojun; Tsow, Francis; Verma, Gaurav; McConnell, Rob; Fruin, Scott; Tao, Nongjian; Forzani, Erica S

    2016-12-03

    A novel portable wireless volatile organic compound (VOC) monitoring device with disposable sensors is presented. The device is miniaturized, light, easy-to-use, and cost-effective. Different field tests have been carried out to identify the operational, analytical, and functional performance of the device and its sensors. The device was compared to a commercial photo-ionization detector, gas chromatography-mass spectrometry, and carbon monoxide detector. In addition, environmental operational conditions, such as barometric change, temperature change and wind conditions were also tested to evaluate the device performance. The multiple comparisons and tests indicate that the proposed VOC device is adequate to characterize personal exposure in many real-world scenarios and is applicable for personal daily use.

  13. A Novel Wireless Wearable Volatile Organic Compound (VOC) Monitoring Device with Disposable Sensors

    PubMed Central

    Deng, Yue; Chen, Cheng; Xian, Xiaojun; Tsow, Francis; Verma, Gaurav; McConnell, Rob; Fruin, Scott; Tao, Nongjian; Forzani, Erica S.

    2016-01-01

    A novel portable wireless volatile organic compound (VOC) monitoring device with disposable sensors is presented. The device is miniaturized, light, easy-to-use, and cost-effective. Different field tests have been carried out to identify the operational, analytical, and functional performance of the device and its sensors. The device was compared to a commercial photo-ionization detector, gas chromatography-mass spectrometry, and carbon monoxide detector. In addition, environmental operational conditions, such as barometric change, temperature change and wind conditions were also tested to evaluate the device performance. The multiple comparisons and tests indicate that the proposed VOC device is adequate to characterize personal exposure in many real-world scenarios and is applicable for personal daily use. PMID:27918484

  14. Evaluation of a new simple collection device for sampling of microparticles in exhaled breath.

    PubMed

    Seferaj, Sabina; Ullah, Shahid; Tinglev, Åsa; Carlsson, Sten; Winberg, Jesper; Stambeck, Peter; Beck, Olof

    2018-03-12

    The microparticle fraction of exhaled breath is of interest for developing clinical biomarkers. Exhaled particles may contain non-volatile components from all parts of the airway system, formed during normal breathing. This study aimed to evaluate a new, simple sampling device, based on impaction, for collecting microparticles from exhaled breath. Performance of the new device was compared with that of the existing SensAbues membrane filter device. The analytical work used liquid chromatography-tandem mass spectrometry methods. The new device collected three subsamples and these were separately analysed from eight individuals. No difference was observed between the centre position (0.91 ng/sample) and the side positions (1.01 ng/sample) using major phosphatidylcholine (PC) 16:0/16:0 as the analyte. Exhaled breath was collected from eight patients on methadone maintenance treatment. The intra-individual variability in measured methadone concentration between the three collectors was 8.7%. In another experiment using patients on methadone maintenance treatment, the sampling efficiency was compared with an established filter device. Compared to the existing device, the efficiency of the new device was 121% greater for methadone and 1450% greater for DPPC. The data from lipid analysis also indicated that a larger fraction of the collected material was from the distal parts. Finally, a study using an optical particle counter indicated that the device preferentially collects the larger particle fraction. In conclusion, this study demonstrates the usefulness of the new device for collecting non-volatile components from exhaled breath. The performance of the device was superior to the filter device in several aspects.

  15. Securing the communication of medical information using local biometric authentication and commercial wireless links.

    PubMed

    Ivanov, Vladimir I; Yu, Paul L; Baras, John S

    2010-09-01

    Medical information is extremely sensitive in nature - a compromise, such as eavesdropping or tampering by a malicious third party, may result in identity theft, incorrect diagnosis and treatment, and even death. Therefore, it is important to secure the transfer of medical information from the patient to the recording system. We consider a portable, wireless device transferring medical information to a remote server. We decompose this problem into two sub-problems and propose security solutions to each of them: (1) to secure the link between the patient and the portable device, and (2) to secure the link between the portable device and the network. Thus we push the limits of the network security to the edge by authenticating the user using their biometric information; authenticating the device to the network at the physical layer; and strengthening the security of the wireless link with a key exchange mechanism. The proposed authentication methods can be used for recording the readings of medical data in a central database and for accessing medical records in various settings.

  16. Comparative ex vivo evaluation of two electronic percussive testing devices measuring the stability of dental implants.

    PubMed

    Geckili, Onur; Bilhan, Hakan; Cilingir, Altug; Bilmenoglu, Caglar; Ates, Gokcen; Urgun, Aliye Ceren; Bural, Canan

    2014-12-01

    A comparative ex vivo study was performed to determine electronic percussive test values (PTVs) measured by cabled and wireless electronic percussive testing (EPT) devices and to evaluate the intra- and interobserver reliability of the wireless EPT device. Forty implants were inserted into the vertebrae and forty into the pelvis of a steer, a safe distance apart. The implants were all 4.3 mm wide and 13 mm long, from the same manufacturer. PTV of each implant was measured by four different examiners, using both EPT devices, and compared. Additionally, the intra- and interobserver reliability of the wireless EPT device was evaluated. Statistically significant differences (P <0.05) were observed between PTVs made by the two EPT devices. PTVs measured by the wireless EPT device were significantly higher than the cabled EPT device (P <0.05), indicating lower implant stability. The intraobserver reliability of the wireless EPT device was evaluated as excellent for the measurements in type II bone and good-to-excellent in type IV bone; interobserver reliability was evaluated as fair-to-good in both bone types. The wireless EPT device gives PTVs higher than the cabled EPT device, indicating lower implant stability, and its inter- and intraobserver reliability is good and acceptable.

  17. Three New Methods for Analysis of Answer Changes

    ERIC Educational Resources Information Center

    Sinharay, Sandip; Johnson, Matthew S.

    2017-01-01

    In a pioneering research article, Wollack and colleagues suggested the "erasure detection index" (EDI) to detect test tampering. The EDI can be used with or without a continuity correction and is assumed to follow the standard normal distribution under the null hypothesis of no test tampering. When used without a continuity correction,…

  18. Magnetic manipulation device for the optimization of cell processing conditions.

    PubMed

    Ito, Hiroshi; Kato, Ryuji; Ino, Kosuke; Honda, Hiroyuki

    2010-02-01

    Variability in human cell phenotypes make it's advancements in optimized cell processing necessary for personalized cell therapy. Here we propose a strategy of palm-top sized device to assist physically manipulating cells for optimizing cell preparations. For the design of such a device, we combined two conventional approaches: multi-well plate formatting and magnetic cell handling using magnetite cationic liposomes (MCLs). From our previous works, we showed the labeling applications of MCL on adhesive cells for various tissue engineering approaches. To feasibly transfer cells in multi-well plate, we here evaluated the magnetic response of MCL-labeled suspension type cells. The cell handling performance of Jurkat cells proved to be faster and more robust compared to MACS (Magnetic Cell Sorting) bead methods. To further confirm our strategy, prototype palm-top sized device "magnetic manipulation device (MMD)" was designed. In the device, the actual cell transportation efficacy of Jurkat cells was satisfying. Moreover, as a model of the most distributed clinical cell processing, primary peripheral blood mononuclear cells (PBMCs) from different volunteers were evaluated. By MMD, individual PBMCs indicated to have optimum Interleukin-2 (IL-2) concentrations for the expansion. Such huge differences of individual cells indicated that MMD, our proposing efficient and self-contained support tool, could assist the feasible and cost-effective optimization of cell processing in clinical facilities. Copyright (c) 2009 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  19. Phase velocity enhancement of linear explosive shock tubes

    NASA Astrophysics Data System (ADS)

    Loiseau, Jason; Serge, Matthew; Szirti, Daniel; Higgins, Andrew; Tanguay, Vincent

    2011-06-01

    Strong, high density shocks can be generated by sequentially detonating a hollow cylinder of explosives surrounding a thin-walled, pressurized tube. Implosion of the tube results in a pinch that travels at the detonation velocity of the explosive and acts like a piston to drive a shock into the gas ahead of it. In order to increase the maximum shock velocities that can be obtained, a phase velocity generator can be used to drag an oblique detonation wave along the gas tube at a velocity much higher than the base detonation velocity of the explosive. Since yielding and failure of the gas tube is the primary limitation of these devices, it is desirable to retain the dynamic confinement effects of a heavy-walled tamper without interfering with operation of the phase velocity generator. This was accomplished by cutting a slit into the tamper and introducing a phased detonation wave such that it asymmetrically wraps around the gas tube. This type of configuration has been previously experimentally verified to produce very strong shocks but the post-shock pressure and shock velocity limits have not been investigated. This study measured the shock trajectory for various fill pressures and phase velocities to ascertain the limiting effects of tube yield, detonation obliquity and pinch aspect ratio.

  20. 78 FR 2618 - Self-Contained Breathing Apparatus Remaining Service-Life Indicator Performance Requirements

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-14

    ... 0920-AA38 Self-Contained Breathing Apparatus Remaining Service-Life Indicator Performance Requirements... requirements for self-contained breathing apparatus (SCBA) remaining service-life indicators or warning devices... self-contained breathing apparatus (SCBA) used in the fire service, and a firefighters' union. A...

  1. EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability

    PubMed Central

    Chan, Jessica E; Netland, Peter A

    2015-01-01

    Trabeculectomy has been the traditional primary surgical therapy for open-angle glaucoma. While trabeculectomy is effective in lowering intraocular pressure, complications associated with the procedure have motivated the development of alternative techniques and devices, including the EX-PRESS Glaucoma Filtration Device. This review describes the efficacy, safety, complication rates, and potential advantages and disadvantages of the EX-PRESS Glaucoma Filtration Device. EX-PRESS implantation is technically simpler compared with that of trabeculectomy, with fewer surgical steps. Vision recovery has been more rapid after EX-PRESS implantation compared with trabeculectomy. Intraocular pressure variation is lower during the early postoperative period, indicating a more predictable procedure. While efficacy of the EX-PRESS implant has been comparable to trabeculectomy, postoperative complications appear less common after EX-PRESS implantation compared with trabeculectomy. The EX-PRESS Glaucoma Filtration Device appears to be safe and effective in the surgical management of open-angle glaucoma. PMID:26366105

  2. Artificial leaf device for solar fuel production.

    PubMed

    Amao, Yutaka; Shuto, Naho; Furuno, Kana; Obata, Asami; Fuchino, Yoshiko; Uemura, Keiko; Kajino, Tsutomu; Sekito, Takeshi; Iwai, Satoshi; Miyamoto, Yasushi; Matsuda, Masatoshi

    2012-01-01

    Solar fuels, such as hydrogen gas produced from water and methanol produced from carbon dioxide reduction by artificial photosynthesis, have received considerable attention. In natural leaves the photosynthetic proteins are well-organized in the thylakoid membrane. To develop an artificial leaf device for solar low-carbon fuel production from CO2, a chlorophyll derivative chlorin-e6 (Chl-e6; photosensitizer), 1-carboxylundecanoyl-1'-methyl-4,4'-bipyrizinium bromide, iodide (CH3V(CH2)9COOH; the electron carrier) and formate dehydrogenase (FDH) (the catalyst) immobilised onto a silica-gel-based thin layer chromatography plate (the Chl-V-FDH device) was investigated. From luminescence spectroscopy measurements, the photoexcited triplet state of Chl-e6 was quenched by the CH3V(CH2)9COOH moiety on the device, indicating the photoinduced electron transfer from the photoexcited triplet state of Chl-e6 to the CH3V(CH2)9COOH moiety. When the CO2-saturated sample solution containing NADPH (the electron donor) was flowed onto the Chl-V-FDH device under visible light irradiation, the formic acid concentration increased with increasing irradiation time.

  3. The cost of assistive devices for children with mobility limitation.

    PubMed

    Korpela, R A; Siirtola, T O; Koivikko, M J

    1992-10-01

    This study evaluated the costs of assistive devices for children with motor limitations at home, in day care, and in school, and the effect of diagnosis and severity of disabilities on costs. 201 children (mean age 7.4 years) who used 1274 various assistive devices (85.7% at home, 6.1% in day care, and 8.2% in school) were studied. The cost per device varied from $8.14 to $8138 with an average value of $539 per device. The distribution of costs per capita was unequal: 52.2% of children used 15.6% of total costs and 4.5% of children used 20.8% of total costs. The severity of motor impairment and the age of the child were the most important indicators associated with the need and cost of assistive devices. Assistive devices for basic needs, such as sitting, mobility, and personal hygiene, had a relatively low effect on costs in comparison with the high-technology devices, like powered wheelchairs and computers. Better cooperation with day care and school professionals, better assessment of needs, follow-up and recirculation of assistive devices are ways to promote rehabilitation services and partly solve the discrepancies between the costs of available technology and the resources to pay for it.

  4. Tactile drawings, ethics, and a sanctuary: metaphoric devices invented by a blind woman.

    PubMed

    Kennedy, John M

    2013-01-01

    Until the last two decades, indications that blind people would understand and create pictures were sparse. EW, a totally blind adult, who began making raised-line drawings in her thirties, created a portfolio of several hundred sketches in nine years. She selects her own topics and invents her treatments of the subjects. What is of special interest here is that two of her drawings, shown in the present paper, depict places but also use devices to indicate one is a sanctuary and the other concerns a tragic era, using metaphor. Lightness of line in a forest drawing indicates it is out of reality, enchanted, and a sanctuary. A tilted grid in a drawing of a Holocaust memorial shows the events at issue were twisted and crooked. The devices are metaphoric and novel. The drawings deal with an ontological category--values--for which metaphorical devices in raised-line depictions have not previously been considered.

  5. The TI-Nspire CAS: A Happy-Medium Mobile Device for Grades 8-16 Mathematics Classrooms

    ERIC Educational Resources Information Center

    Zelkowski, Jeremy

    2011-01-01

    This article justifies classifying the TI-Nspire CAS Touchpad as a mobile device for grades 8-16 mathematics classrooms equipped with a Navigator system. The 2010 Horizon Report: K-12 indicates virtually every secondary school aged child has some sort of mobile device. Yet, many school policies ban the use of mobile devices, preventing students…

  6. Barriers to investigator-initiated deep brain stimulation and device research

    PubMed Central

    Malone, Donald; Okun, Michael S.; Booth, Joan; Machado, Andre G.

    2014-01-01

    The success of device-based research in the clinical neurosciences has overshadowed a critical and emerging problem in the biomedical research environment in the United States. Neuroprosthetic devices, such as deep brain stimulation (DBS), have been shown in humans to be promising technologies for scientific exploration of neural pathways and as powerful treatments. Large device companies have, over the past several decades, funded and developed major research programs. However, both the structure of clinical trial funding and the current regulation of device research threaten investigator-initiated efforts in neurologic disorders. The current atmosphere dissuades clinical investigators from pursuing formal and prospective research with novel devices or novel indications. We review our experience in conducting a federally funded, investigator-initiated, device-based clinical trial that utilized DBS for thalamic pain syndrome. We also explore barriers that clinical investigators face in conducting device-based clinical trials, particularly in early-stage studies or small disease populations. We discuss 5 specific areas for potential reform and integration: (1) alternative pathways for device approval; (2) eliminating right of reference requirements; (3) combining federal grant awards with regulatory approval; (4) consolidation of oversight for human subjects research; and (5) private insurance coverage for clinical trials. Careful reformulation of regulatory policy and funding mechanisms is critical for expanding investigator-initiated device research, which has great potential to benefit science, industry, and, most importantly, patients. PMID:24670888

  7. Supportive techniques and devices for endoscopic submucosal dissection of gastric cancer.

    PubMed

    Sakurazawa, Nobuyuki; Kato, Shunji; Fujita, Itsuo; Kanazawa, Yoshikazu; Onodera, Hiroyuki; Uchida, Eiji

    2012-06-16

    The indications for endoscopic treatment have expanded in recent years, and relatively intestinal-type mucosal stomach carcinomas with a low potential for metastasis are now often resected en bloc by endoscopic submucosal dissection (ESD), even if they measure over 20 mm in size. However, ESD requires complex maneuvers, which entails a long operation time, and is often accompanied by complications such as bleeding and perforation. Many technical developments have been implemented to overcome these complications. The scope, cutting device, hemostasis device, and other supportive devices have been improved. However, even with these innovations, ESD remains a potentially complex procedure. One of the major difficulties is poor visualization of the submucosal layer resulting from the poor countertraction afforded during submucosal dissection. Recently, countertraction devices have been developed. In this paper, we introduce countertraction techniques and devices mainly for gastric cancer.

  8. The potential of medical device industry in technological and economical context

    PubMed Central

    Maresova, Petra; Penhaker, Marek; Selamat, Ali; Kuca, Kamil

    2015-01-01

    The high quality of public health improves not only healthy life expectancy, but also the productivity of labor. The most important part of the health care sector is the medical technology industry. The aim of this study is to analyze the current situation in the medical device industry in Europe, its potential strengths and weaknesses in the context of topical economic and demographic development. The contribution specifies an analysis of the economic state of the medical device industry in the context of demographic development of European Union’s macroeconomic indicators and views of experts in the field of medical device development, concerning the opportunities for entities involved in the medical device market. There is fierce competition on the European market. The innovative activity is stable and well regulated by responsible authorities. Worldwide, the medical device market is expected to grow. PMID:26491337

  9. The potential of medical device industry in technological and economical context.

    PubMed

    Maresova, Petra; Penhaker, Marek; Selamat, Ali; Kuca, Kamil

    2015-01-01

    The high quality of public health improves not only healthy life expectancy, but also the productivity of labor. The most important part of the health care sector is the medical technology industry. The aim of this study is to analyze the current situation in the medical device industry in Europe, its potential strengths and weaknesses in the context of topical economic and demographic development. The contribution specifies an analysis of the economic state of the medical device industry in the context of demographic development of European Union's macroeconomic indicators and views of experts in the field of medical device development, concerning the opportunities for entities involved in the medical device market. There is fierce competition on the European market. The innovative activity is stable and well regulated by responsible authorities. Worldwide, the medical device market is expected to grow.

  10. On-Demand Cell Internal Short Circuit Device

    NASA Technical Reports Server (NTRS)

    Darcy, Eric; Keyser, Matthew

    2014-01-01

    A device implantable in Li-ion cells that can generate a hard internal short circuit on-demand by exposing the cell to 60?C has been demonstrated to be valuable for expanding our understanding of cell responses. The device provides a negligible impact to cell performance and enables the instigation of the 4 general categories of cell internal shorts to determine relative severity and cell design susceptibility. Tests with a 18650 cell design indicates that the anode active material short to the aluminum cathode current collector tends to be more catastrophic than the 3 other types of internal shorts. Advanced safety features (such as shutdown separators) to prevent or mitigate the severity of cell internal shorts can be verified with this device. The hard short success rate achieved to date in 18650 cells is about 80%, which is sufficient for using these cells in battery assemblies for field-failure-relevant, cell-cell thermal runaway propagation verification tests

  11. Diffraction grating-based sensing optofluidic device for measuring the refractive index of liquids.

    PubMed

    Calixto, Sergio; Bruce, Neil C; Rosete-Aguilar, Martha

    2016-01-11

    We describe a simple and versatile optical sensing device for measuring refractive index of liquids. The sensor consists of a sinusoidal relief grating in a glass cell. Device calibration is done by pouring in the cell different liquids of known refractive indices. Each time a liquid is poured first order intensity is measured. The fabrication process and testing of the prototype device is described. An application in the measurement of temperature is also presented.

  12. PLASMA DEVICE

    DOEpatents

    Gow, J.D.; Wilcox, J.M.

    1961-12-26

    A device is designed for producing and confining highenergy plasma from which neutrons are generated in copious quantities. A rotating sheath of electrons is established in a radial electric field and axial magnetic field produced within the device. The electron sheath serves as a strong ionizing medium to gas introdueed thereto and also functions as an extremely effective heating mechanism to the resulting plasma. In addition, improved confinement of the plasma is obtained by ring magnetic mirror fields produced at the ends of the device. Such ring mirror fields are defined by the magnetic field lines at the ends of the device diverging radially outward from the axis of the device and thereafter converging at spatial annular surfaces disposed concentrically thereabout. (AFC)

  13. Critical Dimensions of Water-tamped Slabs and Spheres of Active Material

    DOE R&D Accomplishments Database

    Greuling, E.; Argo, H.: Chew, G.; Frankel, M. E.; Konopinski, E.J.; Marvin, C.; Teller, E.

    1946-08-06

    The magnitude and distribution of the fission rate per unit area produced by three energy groups of moderated neutrons reflected from a water tamper into one side of an infinite slab of active material is calculated approximately in section II. This rate is directly proportional to the current density of fast neutrons from the active material incident on the water tamper. The critical slab thickness is obtained in section III by solving an inhomogeneous transport integral equation for the fast-neutron current density into the tamper. Extensive use is made of the formulae derived in "The Mathematical Development of the End-Point Method" by Frankel and Goldberg. In section IV slight alterations in the theory outlined in sections II and III were made so that one could approximately compute the critical radius of a water-tamper sphere of active material. The derived formulae were applied to calculate the critical dimensions of water-tamped slabs and spheres of solid UF{sub 6} leaving various (25) isotope enrichment fractions. Decl. Dec. 16, 1955.

  14. Physicians interrupted by mobile devices in hospitals: understanding the interaction between devices, roles, and duties.

    PubMed

    Solvoll, Terje; Scholl, Jeremiah; Hartvigsen, Gunnar

    2013-03-07

    A common denominator of modern hospitals is a variety of communication problems. In particular, interruptions from mobile communication devices are a cause of great concern for many physicians. To characterize how interruptions from mobile devices disturb physicians in their daily work. The gathered knowledge will be subsequently used as input for the design and development of a context-sensitive communication system for mobile communications suitable for hospitals. This study adheres to an ethnographic and interpretive field research approach. The data gathering consisted of participant observations, non-structured and mostly ad hoc interviews, and open-ended discussions with a selected group of physicians. Eleven physicians were observed for a total of 135 hours during May and June 2009. The study demonstrates to what degree physicians are interrupted by mobile devices in their daily work and in which situations they are interrupted, such as surgery, examinations, and during patients/relatives high-importance level conversations. The participants in the study expected, and also indicated, that wireless phones probably led to more interruptions immediately after their introduction in a clinic, when compared to a pager, but this changed after a short while. The unpleasant feeling experienced by the caller when interrupting someone by calling them differs compared to sending a page message, which leaves it up to the receiver when to return the call. Mobile devices, which frequently interrupt physicians in hospitals, are a problem for both physicians and patients. The results from this study contribute to knowledge being used as input for designing and developing a prototype for a context-sensitive communication system for mobile communication suitable for hospitals. We combined these findings with results from earlier studies and also involved actual users to develop the prototype, CallMeSmart. This system intends to reduce such interruptions and at the same time

  15. Reduction in radiation exposure to nursing personnel with the use of remote afterloading brachytherapy devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grigsby, P.W.; Perez, C.A.; Eichling, J.

    The radiation exposure to nursing personnel from patients with brachytherapy implants on a large brachytherapy service were reviewed. Exposure to nurses, as determined by TLD monitors, indicates a 7-fold reduction in exposure after the implementation of the use of remote afterloading devices. Quarterly TLD monitor data for six quarters prior to the use of remote afterloading devices demonstrate an average projected annual dose equivalent to the nurses of 152 and 154 mrem (1.5 mSv). After the implementation of the remote afterloading devices, the quarterly TLD monitor data indicate an average dose equivalent per nurse of 23 and 19 mrem (0.2more » mSv). This is an 87% reduction in exposure to nurses with the use of these devices (p less than 0.01).« less

  16. Use of Mobile Devices to Access Resources Among Health Professions Students: A Systematic Review.

    PubMed

    Mi, Misa; Wu, Wendy; Qiu, Maylene; Zhang, Yingting; Wu, Lin; Li, Jie

    2016-01-01

    This systematic review examines types of mobile devices used by health professions students, kinds of resources and tools accessed via mobile devices, and reasons for using the devices to access the resources and tools. The review included 20 studies selected from articles published in English between January 2010 and April 2015, retrieved from PubMed and other sources. Data extracted included participants, study designs, mobile devices used, mobile resources/apps accessed, outcome measures, and advantages of and barriers to using mobile devices. The review indicates significant variability across the studies in terms of research methods, types of mobile programs implemented, resources accessed, and outcomes. There were beneficial effects of using mobile devices to access resources as well as conspicuous challenges or barriers in using mobile devices.

  17. Development of reversible vas deferens occlusive device: IV. Rigid prosthetic devices.

    PubMed

    Drueschke, E E; Zaneveld, L J; Burns, M; Rodzen, R; Wingfield, J R; Maness, J H

    1975-01-01

    Different types of rigid, reversible, vas deferens occlusive devices were developed and evaluated in 14 unilaterally vasectomized dogs. All prosthetic devices had molded silicone rubber bodies, and rigid inflow and outflow tubes. Various techniques for the removal of the vas luminal epithelium, and for the preparation of porous ceramic and etched stainless steel surfaces to encourage tissue ingrowth into the prosthetic device end tubues were attempted. The devices differed in their methods of achieving occlusion. One device used a "rotary stem valve" which had a C-section rotating mechanism; the others used the "shuttle stem valve" which possessed an occlusive element that moved transverse to the axis of flow in the device, thus occluding the device when the stem was depressed. The rotarystem valve was implanted by means of a longitudinal incision. The remaining 13 shuttle stem devices were placed in the vas using either a longitudinal or a transverse implantation. Inno case was sperm transport through the prosthetic devices obtained for more than a few ejaculations.

  18. Formal Analysis of Key Integrity in PKCS#11

    NASA Astrophysics Data System (ADS)

    Falcone, Andrea; Focardi, Riccardo

    PKCS#11 is a standard API to cryptographic devices such as smarcards, hardware security modules and usb crypto-tokens. Though widely adopted, this API has been shown to be prone to attacks in which a malicious user gains access to the sensitive keys stored in the devices. In 2008, Delaune, Kremer and Steel proposed a model to formally reason on this kind of attacks. We extend this model to also describe flaws that are based on integrity violations of the stored keys. In particular, we consider scenarios in which a malicious overwriting of keys might fool honest users into using attacker's own keys, while performing sensitive operations. We further enrich the model with a trusted key mechanism ensuring that only controlled, non-tampered keys are used in cryptographic operations, and we show how this modified API prevents the above mentioned key-replacement attacks.

  19. Measurements of Anisotropy in Non-LTE Low-Density, Iron-Vanadium Plasmas

    NASA Astrophysics Data System (ADS)

    Jarrott, L. C.; Foord, M. E.; Heeter, R. F.; Liedahl, D. A.; Barrios, M. A.; Brown, G. V.; Gray, W.; Marley, E. V.; Mauche, C. W.; Widmann, K.; Schneider, M. B.

    2016-10-01

    We report on Non-LTE anisotropy experiments carried out on the Omega Laser Facility at the Laboratory for Laser Energetics, Rochester NY. In these experiments, a 50/50 mixture of iron and vanadium, 2000A thick and 250um in diameter is contained within a beryllium tamper, 10um thick and 1000um in diameter. Each side of the beryllium tamper is then irradiated using 52 of the 60 Omega beams with an intensity of 3e14 W/cm2 over 3ns in duration. Iron-Vanadium line ratios indicate a plasma temperature of greater than 2 keV was produced. The geometrical aspect ratio ranged from 0.8 to 4.0; allowing for the characterization of optical-depth-dependent anisotropy in the iron-vanadium line emission. Results of this characterization and its comparison with modeling will be presented. This work performed under the auspices of U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  20. Medical Devices; General Hospital and Personal Use Devices; Classification of the Ultraviolet Radiation Chamber Disinfection Device. Final order.

    PubMed

    2015-11-20

    The Food and Drug Administration (FDA or the Agency) is classifying the ultraviolet (UV) radiation chamber disinfection device into class II (special controls). The special controls that will apply to the device are identified in this order and will be part of the codified language for the UV radiation chamber disinfection device classification. The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device.

  1. Decision Support for the Capacity Management of Bronchoscopy Devices: Optimizing the Cost-Efficient Mix of Reusable and Single-Use Devices Through Mathematical Modeling.

    PubMed

    Edenharter, Günther M; Gartner, Daniel; Pförringer, Dominik

    2017-06-01

    Increasing costs of material resources challenge hospitals to stay profitable. Particularly in anesthesia departments and intensive care units, bronchoscopes are used for various indications. Inefficient management of single- and multiple-use systems can influence the hospitals' material costs substantially. Using mathematical modeling, we developed a strategic decision support tool to determine the optimum mix of disposable and reusable bronchoscopy devices in the setting of an intensive care unit. A mathematical model with the objective to minimize costs in relation to demand constraints for bronchoscopy devices was formulated. The stochastic model decides whether single-use, multi-use, or a strategically chosen mix of both device types should be used. A decision support tool was developed in which parameters for uncertain demand such as mean, standard deviation, and a reliability parameter can be inserted. Furthermore, reprocessing costs per procedure, procurement, and maintenance costs for devices can be parameterized. Our experiments show for which demand pattern and reliability measure, it is efficient to only use reusable or disposable devices and under which circumstances the combination of both device types is beneficial. To determine the optimum mix of single-use and reusable bronchoscopy devices effectively and efficiently, managers can enter their hospital-specific parameters such as demand and prices into the decision support tool.The software can be downloaded at: https://github.com/drdanielgartner/bronchomix/.

  2. Computational Investigation of the NASA Cascade Cyclonic Separation Device

    NASA Technical Reports Server (NTRS)

    Hoyt, Nathaniel C.; Kamotani, Yasuhiro; Kadambi, Jaikrishnan; McQuillen, John B.; Sankovic, John M.

    2008-01-01

    Devices designed to replace the absent buoyancy separation mechanism within a microgravity environment are of considerable interest to NASA as the functionality of many spacecraft systems are dependent on the proper sequestration of interpenetrating gas and liquid phases. Inasmuch, a full multifluid Euler-Euler computational fluid dynamics investigation has been undertaken to evaluate the performance characteristics of one such device, the Cascade Cyclonic Separator, across a full range of inlet volumetric quality with combined volumetric injection rates varying from 1 L/min to 20 L/min. These simulations have delimited the general modes of operation of this class of devices and have proven able to describe the complicated vortex structure and induced pressure gradients that arise. The computational work has furthermore been utilized to analyze design modifications that enhance the overall performance of these devices. The promising results indicate that proper CFD modeling may be successfully used as a tool for microgravity separator design.

  3. Attracting Attention for the Cause. The Reporting of Three Indices in the UK National Press

    ERIC Educational Resources Information Center

    Morse, Stephen

    2011-01-01

    Indicators and indices (a collection of indicators into a single value) have been promoted for some time as convenient devices for the presentation of complex datasets to a more general audience. Examples of indices are the corruption perception index (CPI), human development index (HDI) and ecological footprint (EF). The research reported in this…

  4. Security Management of Electronic Data Interchange

    DTIC Science & Technology

    1993-06-01

    48 6. Signatures by Tamper-Resistent Electronic seal .................................. 49 7. Resolution of Disputes...Trademark by RSA). Secure communication is not possible without any pi eu uous relationship between parties. Electronic mail may be sealed in a...public key certification. [Ref. 321 6. Signatures by Tamper-Resistent Electronic seal There is a separation between encryption and decryption in a public

  5. Energy transport in cooling device by magnetic fluid

    NASA Astrophysics Data System (ADS)

    Yamaguchi, Hiroshi; Iwamoto, Yuhiro

    2017-06-01

    Temperature sensitive magnetic fluid has a great potential with high performance heat transport ability as well as long distance energy (heat) transporting. In the present study experimental set-up was newly designed and constructed in order to measure basic heat transport characteristics under various magnetic field conditions. Angular dependence for the device (heat transfer section) was also taken into consideration for a sake of practical applications. The energy transfer characteristic (heat transport capability) in the magnetically-driven heat transport (cooling) device using the binary TSMF was fully investigated with the set-up. The obtained results indicate that boiling of the organic mixture (before the magnetic fluid itself reaching boiling point) effectively enhances the heat transfer as well as boosting the flow to circulate in the closed loop by itself. A long-distance heat transport of 5 m is experimentally confirmed, transferring the thermal energy of 35.8 W, even when the device (circulation loop) is horizontally placed. The highlighted results reveal that the proposed cooling device is innovative in a sense of transporting substantial amount of thermal energy (heat) as well as a long distance heat transport. The development of the magnetically-driven heat transport device has a great potential to be replaced for the conventional heat pipe in application of thermal engineering.

  6. Photovoltaic device

    DOEpatents

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-06-02

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  7. Photovoltaic device

    DOEpatents

    Reese, Jason A; Keenihan, James R; Gaston, Ryan S; Kauffmann, Keith L; Langmaid, Joseph A; Lopez, Leonardo; Maak, Kevin D; Mills, Michael E; Ramesh, Narayan; Teli, Samar R

    2017-03-21

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  8. Antiprogestin-releasing intrauterine devices

    PubMed Central

    Nayak, NR; Slayden, OD; Mah, K; Chwalisz, K; Brenner, Robert M

    2007-01-01

    Intrauterine devices (IUDs) that release progestins are highly effective contraceptives, but they induce breakthrough bleeding that some women find unacceptable. Because progesterone (P) antagonists (AP) are known to suppress the endometrium, induce amenorrhea, and inhibit fertility, AP IUDs may provide an effective contraceptive that also controls endometrial bleeding. Here we assessed the effects of empty (blank) vs AP-releasing (ZK 230 211) IUDs on bleeding patterns and endometrial growth in ovariectomized, artificially cycled macaques. The AP IUDs (but not the blank controls) induced extended, frank menstruation when inserted during the late luteal phase, an indication of local AP action. Over time, endometrial glandular and arterial proliferation were inhibited, steroid receptors were elevated, spiral arteries showed degenerative changes, progesterone withdrawal bleeding was prevented and estradiol-dependent proliferation was suppressed by the AP IUDs. In sum, AP IUDs suppressed the effects of P on endometrial progestational development and blocked the effects of estradiol on endometrial proliferation as previously shown for systemic treatment with APs. Therefore, AP IUDs may provide novel contraceptive devices with minimal breakthrough bleeding. PMID:17531599

  9. Method and system for reducing device performance degradation of organic devices

    DOEpatents

    Teague, Lucile C.

    2014-09-02

    Methods and systems for reducing the deleterious effects of gate bias stress on the drain current of an organic device, such as an organic thin film transistor, are provided. In a particular aspect, the organic layer of an organic device is illuminated with light having characteristics selected to reduce the gate bias voltage effects on the drain current of the organic device. For instance, the wavelength and intensity of the light are selected to provide a desired recovery of drain current of the organic device. If the characteristics of the light are appropriately matched to the organic device, recovery of the deleterious effects caused by gate bias voltage stress effects on the drain current of the organic device can be achieved. In a particular aspect, the organic device is selectively illuminated with light to operate the organic device in multiple modes of operation.

  10. [Mandibular advancement devices in the treatment of obstructive sleep apnea].

    PubMed

    Korczyński, Piotr; Górska, Katarzyna; Wilk, Krzysztof; Bielicki, Piotr; Byśkiniewicz, Krzysztof; Baczkowski, Tadeusz

    2004-12-01

    Obstructive sleep apnea (OSA) affects approximately 450,000 people in Poland. Use of nasal continuous positive airway pressure (nCPAP) devices and laryngeal surgery are widely accepted OSA treatment methods. In 1995 ASDA approved oral devices for treatment of OSA patients. The aim of the study was to determine efficiency of mandibular advancement devices (MAD) in OSA therapy. The study group included 20 patients with OSA, all of whom did not tolerate nCPAP and did not have indications or did not agree for surgical treatment. Control polysomnography was carried out in 11 patients using MAD. In 64% of patients AHI was lower then 10. No correlation between MAD use and AHI values was found. 45% of patients declared improvement of sleep quality and life comfort. Use of mandibular advancement devices is an important alternative therapy of OSA.

  11. High voltage semiconductor devices and methods of making the devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matocha, Kevin; Chatty, Kiran; Banerjee, Sujit

    A multi-cell MOSFET device including a MOSFET cell with an integrated Schottky diode is provided. The MOSFET includes n-type source regions formed in p-type well regions which are formed in an n-type drift layer. A p-type body contact region is formed on the periphery of the MOSFET. The source metallization of the device forms a Schottky contact with an n-type semiconductor region adjacent the p-type body contact region of the device. Vias can be formed through a dielectric material covering the source ohmic contacts and/or Schottky region of the device and the source metallization can be formed in the vias.more » The n-type semiconductor region forming the Schottky contact and/or the n-type source regions can be a single continuous region or a plurality of discontinuous regions alternating with discontinuous p-type body contact regions. The device can be a SiC device. Methods of making the device are also provided.« less

  12. High voltage semiconductor devices and methods of making the devices

    DOEpatents

    Matocha, Kevin; Chatty, Kiran; Banerjee, Sujit

    2017-02-28

    A multi-cell MOSFET device including a MOSFET cell with an integrated Schottky diode is provided. The MOSFET includes n-type source regions formed in p-type well regions which are formed in an n-type drift layer. A p-type body contact region is formed on the periphery of the MOSFET. The source metallization of the device forms a Schottky contact with an n-type semiconductor region adjacent the p-type body contact region of the device. Vias can be formed through a dielectric material covering the source ohmic contacts and/or Schottky region of the device and the source metallization can be formed in the vias. The n-type semiconductor region forming the Schottky contact and/or the n-type source regions can be a single continuous region or a plurality of discontinuous regions alternating with discontinuous p-type body contact regions. The device can be a SiC device. Methods of making the device are also provided.

  13. Visualization of energy: light dose indicator based on electrochromic gyroid nano-materials

    NASA Astrophysics Data System (ADS)

    Wei, Di; Scherer, Maik R. J.; Astley, Michael; Steiner, Ullrich

    2015-06-01

    The typical applications of electrochromic devices do not make use of the charge-dependent, gradual optical response due to their slow voltage-sensitive coloration. However, in this paper we present a design for a reusable, self-powered light dose indicator consisting of a solar cell and a gyroid-structured nickel oxide (NiO) electrochromic display that measures the cumulative charge per se, making use of the efficient voltage-sensitive coloration of gyroid materials. To circumvent the stability issues associated with the standard aqueous electrolyte that is typically accompanied by water splitting and gas evolution, we investigate a novel nano-gyroid NiO electrochromic device based on organic solvents of 1,1,1,3,3,3-hexafluoropropan-2-ol, and room temperature ionic liquid (RTIL) triethylsulfonium bis(trifluoromethylsulfonyl) imide ([SET3][TFSI]) containing lithium bis(trifluoromethylsulfonyl) imide. We show that an effective light dose indicator can be enabled by nano-gyroid NiO with RTIL; this proves to be a reliable device since it does not involve solvent degradation or gas generation.

  14. Devices for home evaluation of women's health concerns.

    PubMed

    Scolaro, Kelly L; Lloyd, Kimberly Braxton; Helms, Kristen L

    2008-02-15

    Devices used for home evaluation of fertility, pregnancy, menopause, colon cancer, breast cancer, and urinary-tract and vaginal yeast infections are discussed. Ovulation-prediction devices monitor natural changes in a woman's body during the menstrual cycle, including changes in basal body temperature, urinary luteinizing hormone, and urinary estrone-3-glucuronide concentrations. Also available are devices that identify changes in the content of sodium chloride and other electrolytes in saliva and cervical-vaginal mucus. Home pregnancy tests are designed to detect human chorionic gonadotropin in the urine. Both urine and saliva tests are available for home evaluation of menopause; the most common devices use urine to measure follicle-stimulating hormone. The saliva tests measure estradiol, progesterone, and testosterone. Devices for home screening for colon cancer use either the guaiac test or the fecal immunochemical test. For aid in breast self-examination, patients may use a simulated-breast product designed to train them to detect lumps or a thin, silicone-containing pad intended to increase the sensitivity of the fingers to abnormalities. Urine-dipstick tests can be used to screen for urinary-tract infection, and a swab or panty liner can be used to detect vaginal pH changes indicative of vaginal yeast infection. Home-based tests may be convenient and economical but also have limitations; pharmacists can help educate patients and clinicians. Many devices are available to help evaluate women's health concerns at home.

  15. Potential of connected devices to optimize cattle reproduction.

    PubMed

    Saint-Dizier, Marie; Chastant-Maillard, Sylvie

    2018-05-01

    Estrus and calving are two major events of reproduction that benefit from connected devices because of their crucial importance in herd economics and the amount of time required for their detection. The objectives of this review are to: 1) provide an update on performances reached by sensor systems to detect estrus and calving time; 2) discuss current economic issues related to connected devices for the management of cattle reproduction; 3) propose perspectives for these devices. The main physiological parameters monitored separately or in combination by connected devices are the cow activity, body temperature and rumination or eating behavior. The combination of several indicators in one sensor may maximize the performances of estrus and calving detection. An effort remains to be made for the prediction of calvings that will require human assistance (dystocia). The main reasons to invest in connected devices are to optimize herd reproductive performances and reduce labor on farm. The economic benefit was evaluated for estrus detection and depends on the initial herd performances, herd size, labor cost and price of the equipment. Major issues associated with the use of automated sensor systems are the weight of financial investment, the lack of economic analysis and limited skills of the users to manage associated technologies. In the near future, connected devices may allow a precise phenotyping of reproductive and health traits on animals and could help to improve animal welfare and public perception of animal production. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Improvement of contact grating device for efficient terahertz wave generation using bi-angular filter

    NASA Astrophysics Data System (ADS)

    Nagashima, Keisuke; Tsubouchi, Masaaki; Ochi, Yoshihiro; Maruyama, Momoko

    2018-03-01

    We have proposed an improved contact grating device for generating terahertz waves efficiently and have succeeded in developing the device with a very high diffraction efficiency and a wide spectral width. This device has a bi-angular filter and a Fabry-Perot-type structure, which are composed of dielectric multilayers. The bi-angular filter is designed to reflect the 0th-order wave and transmit the-1st-order diffraction wave. Numerical calculations indicate that the new device has a maximum diffraction efficiency over 99% and a spectral width of approximately 20 nm. We measured a high efficiency of 90% over a broad spectral range using a fabricated device.

  17. Consumers' Use of Personal Electronic Devices in the Kitchen.

    PubMed

    Lando, Amy M; Bazaco, Michael C; Chen, Yi

    2018-02-23

    Smartphones, tablets, and other personal electronic devices have become ubiquitous in Americans' daily lives. These devices are used by people throughout the day, including while preparing food. For example, a device may be used to look at recipes and therefore be touched multiple times during food preparation. Previous research has indicated that cell phones can harbor bacteria, including opportunistic human pathogens such as Staphylococcus and Klebsiella spp. This investigation was conducted with data from the 2016 Food Safety Survey (FSS) and from subsequent focus groups to determine the frequency with which consumers use personal electronic devices in the kitchen while preparing food, the types of devices used, and hand washing behaviors after handling these devices. The 2016 FSS is the seventh wave of a repeated cross-sectional survey conducted by the U.S. Food and Drug Administration in collaboration with the U.S. Department of Agriculture. The goal of the FSS is to evaluate U.S. adult consumer attitudes, behaviors, and knowledge about food safety. The FSS included 4,169 adults that were contacted using a dual-frame (land line and cell phone interviews) random-digit-dial sampling process. The personal electronics module was the first of three food safety topics discussed by each of eight consumer focus groups, which were convened in four U.S. cities in fall 2016. Results from the 2016 FSS revealed that of those individuals who use personal electronic devices while cooking, only about one third reported washing hands after touching the device and before continuing cooking. This proportion is significantly lower than that for self-reported hand washing behaviors after touching risky food products such as raw eggs, meat, chicken, or fish. Results from the focus groups highlight the varied usage of these devices during food preparation and the related strategies consumers are using to incorporate personal electric devices into their cooking routines.

  18. Photovoltaic device

    DOEpatents

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-09-01

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device (10) with a multilayered photovoltaic cell assembly (100) and a body portion (200) joined at an interface region (410) and including an intermediate layer (500), at least one interconnecting structural member (1500), relieving feature (2500), unique component geometry, or any combination thereof.

  19. 16 CFR 1507.9 - Toy smoke devices and flitter devices.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... SUBSTANCES ACT REGULATIONS FIREWORKS DEVICES § 1507.9 Toy smoke devices and flitter devices. (a) Toy smoke... shall not be of such color and configuration so as to be confused with banned fireworks such as M-80...

  20. Fluid sampling device

    NASA Technical Reports Server (NTRS)

    Studenick, D. K. (Inventor)

    1977-01-01

    An inlet leak is described for sampling gases, more specifically, for selectively sampling multiple fluids. This fluid sampling device includes a support frame. A plurality of fluid inlet devices extend through the support frame and each of the fluid inlet devices include a longitudinal aperture. An opening device that is responsive to a control signal selectively opens the aperture to allow fluid passage. A closing device that is responsive to another control signal selectively closes the aperture for terminating further fluid flow.

  1. APPLICATION OF SEMIPERMEABLE MEMBRANE DEVICES TO INDOOR AIR SAMPLING

    EPA Science Inventory

    Semipermeable membrane devices (SPMDs) are a relatively new passive sampling technique for nonpolar organic compounds that have been extensively used for surface water sampling. A small body of literature indicates that SPMDs are also useful for air sampling. Because SPMDs ha...

  2. The 1995 Medical Device Technology raw materials survey.

    PubMed

    Pearson, L S

    1995-09-01

    Using information supplied by manufacturers, this article reports on the use of raw materials and compounding and conversion practices in the European medical device manufacturing industry. The findings of the survey provide an indication of which materials are being used and how frequently, and the process of selecting suppliers.

  3. Electrical transport and low-frequency noise in chemical vapor deposited single-layer MoS2 devices.

    PubMed

    Sharma, Deepak; Amani, Matin; Motayed, Abhishek; Shah, Pankaj B; Birdwell, A Glen; Najmaei, Sina; Ajayan, Pulickel M; Lou, Jun; Dubey, Madan; Li, Qiliang; Davydov, Albert V

    2014-04-18

    We have studied temperature-dependent (77-300 K) electrical characteristics and low-frequency noise (LFN) in chemical vapor deposited (CVD) single-layer molybdenum disulfide (MoS2) based back-gated field-effect transistors (FETs). Electrical characterization and LFN measurements were conducted on MoS2 FETs with Al2O3 top-surface passivation. We also studied the effect of top-surface passivation etching on the electrical characteristics of the device. Significant decrease in channel current and transconductance was observed in these devices after the Al2O3 passivation etching. For passivated devices, the two-terminal resistance variation with temperature showed a good fit to the activation energy model, whereas for the etched devices the trend indicated a hopping transport mechanism. A significant increase in the normalized drain current noise power spectral density (PSD) was observed after the etching of the top passivation layer. The observed channel current noise was explained using a standard unified model incorporating carrier number fluctuation and correlated surface mobility fluctuation mechanisms. Detailed analysis of the gate-referred noise voltage PSD indicated the presence of different trapping states in passivated devices when compared to the etched devices. Etched devices showed weak temperature dependence of the channel current noise, whereas passivated devices exhibited near-linear temperature dependence.

  4. A Mechanism for Anonymous Credit Card Systems

    NASA Astrophysics Data System (ADS)

    Tamura, Shinsuke; Yanase, Tatsuro

    This paper proposes a mechanism for anonymous credit card systems, in which each credit card holder can conceal individual transactions from the credit card company, while enabling the credit card company to calculate the total expenditures of transactions of individual card holders during specified periods, and to identify card holders who executed dishonest transactions. Based on three existing mechanisms, i.e. anonymous authentication, blind signature and secure statistical data gathering, together with implicit transaction links proposed here, the proposed mechanism enables development of anonymous credit card systems without assuming any absolutely trustworthy entity like tamper resistant devices or organizations faithful both to the credit card company and card holders.

  5. Medical devices; hematology and pathology devices; classification of the Factor V Leiden DNA mutation detection systems devices. Final rule.

    PubMed

    2004-03-16

    The Food and Drug Administration (FDA) is classifying the Factor V Leiden deoxyribonucleic acid (DNA) mutation detections systems device into class II (special controls). The special control that will apply to the device is the guidance document entitled "Class II Special Controls Guidance Document: Factor V Leiden DNA Mutation Detection Systems." The agency is taking this action in response to a petition submitted under the Federal Food, Drug, and Cosmetic Act (the act) as amended by the Medical Device Amendments of 1976 (the 1976 amendments), the Safe Medical Devices Act of 1990 (SMDA), the Food and Drug Administration Modernization Act of 1997 (FDAMA), and the Medical Device User Fee and Modernization Act of 2002. The agency is classifying this device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device. Elsewhere in this issue of the Federal Register, FDA is publishing a notice of availability of a guidance document that is the special control for this device.

  6. A practical guide for the fabrication of microfluidic devices using glass and silicon

    PubMed Central

    Iliescu, Ciprian; Taylor, Hayden; Avram, Marioara; Miao, Jianmin; Franssila, Sami

    2012-01-01

    This paper describes the main protocols that are used for fabricating microfluidic devices from glass and silicon. Methods for micropatterning glass and silicon are surveyed, and their limitations are discussed. Bonding methods that can be used for joining these materials are summarized and key process parameters are indicated. The paper also outlines techniques for forming electrical connections between microfluidic devices and external circuits. A framework is proposed for the synthesis of a complete glass/silicon device fabrication flow. PMID:22662101

  7. Beginning hip arthroscopy: indications, positioning, portals, basic techniques, and complications.

    PubMed

    Smart, L Ryan; Oetgen, Matthew; Noonan, Benjamin; Medvecky, Michael

    2007-12-01

    Hip arthroscopy is becoming increasingly popular for the diagnosis and treatment of hip pathology, and the indications continue to evolve. The two most common approaches are the supine and lateral decubitus position. Both approaches can be performed effectively; however, each approach has its own benefits and drawbacks. In this review we will describe the indications for hip arthroscopy, the pros and cons of each approach, and the necessary equipment, portals, portal placement, commercially available distraction devices, and complications.

  8. Microfluidic Device

    NASA Technical Reports Server (NTRS)

    Tai, Yu-Chong (Inventor); Kasdan, Harvey L. (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor)

    2016-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  9. Microfluidic Device

    NASA Technical Reports Server (NTRS)

    Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey (Inventor); Tai, Yu-Chong (Inventor)

    2015-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  10. Microfluidic Device

    NASA Technical Reports Server (NTRS)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2017-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  11. Sealing device

    DOEpatents

    Garcia-Crespo, Andres Jose

    2013-12-10

    A sealing device for sealing a gap between a dovetail of a bucket assembly and a rotor wheel is disclosed. The sealing device includes a cover plate configured to cover the gap and a retention member protruding from the cover plate and configured to engage the dovetail. The sealing device provides a seal against the gap when the bucket assemply is subjected to a centrifugal force.

  12. Rapid and Checkable Electrical Post-Treatment Method for Organic Photovoltaic Devices

    PubMed Central

    Park, Sangheon; Seo, Yu-Seong; Shin, Won Suk; Moon, Sang-Jin; Hwang, Jungseek

    2016-01-01

    Post-treatment processes improve the performance of organic photovoltaic devices by changing the microscopic morphology and configuration of the vertical phase separation in the active layer. Thermal annealing and solvent vapor (or chemical) treatment processes have been extensively used to improve the performance of bulk-heterojunction (BHJ) organic photovoltaic (OPV) devices. In this work we introduce a new post-treatment process which we apply only electrical voltage to the BHJ-OPV devices. We used the commercially available P3HT [Poly(3-hexylthiophene)] and PC61BM (Phenyl-C61-Butyric acid Methyl ester) photovoltaic materials as donor and acceptor, respectively. We monitored the voltage and current applied to the device to check for when the post-treatment process had been completed. This electrical treatment process is simpler and faster than other post-treatment methods, and the performance of the electrically treated solar cell is comparable to that of a reference (thermally annealed) device. Our results indicate that the proposed treatment process can be used efficiently to fabricate high-performance BHJ-OPV devices. PMID:26932767

  13. Control Board Digital Interface Input Devices – Touchscreen, Trackpad, or Mouse?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas A. Ulrich; Ronald L. Boring; Roger Lew

    The authors collaborated with a power utility to evaluate input devices for use in the human system interface (HSI) for a new digital Turbine Control System (TCS) at a nuclear power plant (NPP) undergoing a TCS upgrade. A standalone dynamic software simulation of the new digital TCS and a mobile kiosk were developed to conduct an input device study to evaluate operator preference and input device effectiveness. The TCS software presented the anticipated HSI for the TCS and mimicked (i.e., simulated) the turbine systems’ responses to operator commands. Twenty-four licensed operators from the two nuclear power units participated in themore » study. Three input devices were tested: a trackpad, mouse, and touchscreen. The subjective feedback from the survey indicates the operators preferred the touchscreen interface. The operators subjectively rated the touchscreen as the fastest and most comfortable input device given the range of tasks they performed during the study, but also noted a lack of accuracy for selecting small targets. The empirical data suggest the mouse input device provides the most consistent performance for screen navigation and manipulating on screen controls. The trackpad input device was both empirically and subjectively found to be the least effective and least desired input device.« less

  14. Device fabrication, characterization, and thermal neutron detection response of LiZnP and LiZnAs semiconductor devices

    NASA Astrophysics Data System (ADS)

    Montag, Benjamin W.; Ugorowski, Philip B.; Nelson, Kyle A.; Edwards, Nathaniel S.; McGregor, Douglas S.

    2016-11-01

    Nowotny-Juza compounds continue to be explored as candidates for solid-state neutron detectors. Such a device would have greater efficiency, in a compact form, than present day gas-filled 3He and 10BF3 detectors. The 6Li(n,t)4He reaction yields a total Q-value of 4.78 MeV, larger than 10B, an energy easily identified above background radiations. Hence, devices fabricated from semiconductor compounds having either natural Li (nominally 7.5% 6Li) or enriched 6Li (usually 95% 6Li) as constituent atoms may provide a material for compact high efficiency neutron detectors. Starting material was synthesized by preparing equimolar portions of Li, Zn, and As sealed under vacuum (10-6 Torr) in quartz ampoules lined with boron nitride and subsequently reacted in a compounding furnace [1]. The raw synthesized material indicated the presence high impurity levels (material and electrical property characterizations). A static vacuum sublimation in quartz was performed to help purify the synthesized material [2,3]. Bulk crystalline samples were grown from the purified material [4,5]. Samples were cut using a diamond wire saw, and processed into devices. Bulk resistivity was determined from I-V curve measurements, ranging from 106-1011 Ω cm. Devices were characterized for sensitivity to 5.48 MeV alpha particles, 337 nm laser light, and neutron sensitivity in a thermal neutron diffracted beam at the Kansas State University TRIGA Mark II nuclear reactor. Thermal neutron reaction product charge induction was measured with a LiZnP device, and the reaction product spectral response was observed.

  15. The Minimum Data Set Prevalence of Restraint Quality Indicator: Does It Reflect Differences in Care?

    ERIC Educational Resources Information Center

    Schnelle, John F.; Bates-Jensen, Barbara M.; Levy-Storms, Lene; Grbic, Valena; Yoshii, June; Cadogan, Mary; Simmons, Sandra F.

    2004-01-01

    Purpose: This study investigated whether the use of restraining devices and related measures of care quality are different in nursing homes that score in the upper and lower quartiles on the Minimum Data Set (MDS) "prevalence of restraint" quality indicator, which assesses daily use of restraining devices when residents are out of bed. Design and…

  16. Light-Stimulated Synaptic Devices Utilizing Interfacial Effect of Organic Field-Effect Transistors.

    PubMed

    Dai, Shilei; Wu, Xiaohan; Liu, Dapeng; Chu, Yingli; Wang, Kai; Yang, Ben; Huang, Jia

    2018-06-14

    Synaptic transistors stimulated by light waves or photons may offer advantages to the devices, such as wide bandwidth, ultrafast signal transmission, and robustness. However, previously reported light-stimulated synaptic devices generally require special photoelectric properties from the semiconductors and sophisticated device's architectures. In this work, a simple and effective strategy for fabricating light-stimulated synaptic transistors is provided by utilizing interface charge trapping effect of organic field-effect transistors (OFETs). Significantly, our devices exhibited highly synapselike behaviors, such as excitatory postsynaptic current (EPSC) and pair-pulse facilitation (PPF), and presented memory and learning ability. The EPSC decay, PPF curves, and forgetting behavior can be well expressed by mathematical equations for synaptic devices, indicating that interfacial charge trapping effect of OFETs can be utilized as a reliable strategy to realize organic light-stimulated synapses. Therefore, this work provides a simple and effective strategy for fabricating light-stimulated synaptic transistors with both memory and learning ability, which enlightens a new direction for developing neuromorphic devices.

  17. 2007 Beyond SBIR Phase II: Bringing Technology Edge to the Warfighter

    DTIC Science & Technology

    2007-08-23

    Systems Trade-Off Analysis and Optimization Verification and Validation On-Board Diagnostics and Self - healing Security and Anti-Tampering Rapid...verification; Safety and reliability analysis of flight and mission critical systems On-Board Diagnostics and Self - Healing Model-based monitoring and... self - healing On-board diagnostics and self - healing ; Autonomic computing; Network intrusion detection and prevention Anti-Tampering and Trust

  18. Naval Arms Control: A Post-Cold War Reappraisal

    DTIC Science & Technology

    1991-06-01

    94 A . BACKGRO UN D ......................................................................................... 94 B. WHY ...control, but that an appropriate time may come to exist in the future. For reasons why naval arms control may make more sense in the future, but not...34. Current Research on Peace And Violence. Tampere Peace Research Institute, Tampere Finland, Vol XIII, No. 2, 1990, pp. 65-86. For reasons why naval

  19. Teaching individuals with intellectual disability to email across multiple device platforms.

    PubMed

    Cihak, David F; McMahon, Donald; Smith, Cate C; Wright, Rachel; Gibbons, Melinda M

    2014-11-20

    The purpose of this study was to examine the use of email by people with intellectual disability across multiple technological devices or platforms. Four individuals with intellectual disability participated in this study. Participants were taught how to access and send an email on a Windows desktop computer, laptop, and an iPad tablet device. Results indicated a functional relation. All participants acquired and generalized sending and receiving an email from multiple platforms. Conclusions are discussed about the importance of empowering people with intellectual disability by providing multiple means of expression, including the ability to communicate effectively using a variety of devices. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Long-term central venous access device selection.

    PubMed

    Gabriel, Janice

    Infusion therapy is often viewed as a means to an end - a way to administer medications and fluids. It is one of the few specialties that affect almost all areas of healthcare. Safe, effective and reliable vascular access should be the goal of every health professional who is starting a patient on a prescribed course of intravenous therapy, especially if that patient is undergoing a prolonged course. This article aims to refresh and update nurses' clinical knowledge of the detailed patient assessment required before choosing a central venous access device, as well as supporting a reduction in complications and earlier recognition of potential problems. It discusses clinical indications for devices, the range of long-term intravenous therapies that can be used, and patient assessment.

  1. New-generation devices for transcatheter aortic valve implantation.

    PubMed

    Gatto, Laura; Biondi-Zoccai, Giuseppe; Romagnoli, Enrico; Frati, Giacomo; Prati, Francesco; Giordano, Arturo

    2018-04-20

    Transcatheter aortic valve implantation (TAVI) has overcome the pioneering phase and thanks to accrued clinical evidence has become a mainstay alternative to surgical aortic valve replacement (SAVR) in patients at high risk for post-operative complications. Despite these successes, TAVI remains a junior technology facing momentous developments in techniques and devices. Indeed, several new-generation devices for TAVI have become available in the last few years, including Acurate, Allegra, Evolut, Lotus, JenaValve, Portico, and SAPIEN3. Despite the inevitable setbacks, such as the one represented by DirectFlow, these new devices appear associated with comparative benefits, especially for minimal invasiveness, rates of permanent pacemaker implantation, and risk of residual aortic regurgitation. Indeed, no single device appears clearly better than the others, and a tailored and individualized approach should be sought in using these prostheses, taking into account operator and institutional expertise, on top of patient features. Few comparative effectiveness studies are available to date to guide decision making, and thus careful scrutiny is needed even in everyday clinical practice, especially if seeking to expand the current indications of TAVI. Further guidance will however come from long-term follow-up of completed studies and from results of ongoing trials.

  2. Enhancement of sun-tracking with optoelectronic devices

    NASA Astrophysics Data System (ADS)

    Wu, Jiunn-Chi

    2015-09-01

    Sun-tracking is one of the most challenging tasks in implementing CPV. In order to justify the additional complexity of sun-tracking, careful assessment of performance of CPV by monitoring the performance of sun-tracking is vital. Measurement of accuracy of sun-tracking is one of the important tasks in an outdoor test. This study examines techniques with three optoelectronic devices (i.e. position sensitive device (PSD), CCD and webcam). Outdoor measurements indicated that during sunny days (global horizontal insolation (GHI) > 700 W/m2), three devices recorded comparable tracking accuracy of 0.16˜0.3°. The method using a PSD has fastest sampling rate and is able to detect the sun's position without additional image processing. Yet, it cannot identify the sunlight effectively during low insolation. The techniques with a CCD and a webcam enhance the accuracy of centroid of sunlight via the optical lens and image processing. The image quality acquired using a webcam and a CCD is comparable but the webcam is more affordable than that of CCD because it can be assembled with consumer-graded products.

  3. Accelerated Aging System for Prognostics of Power Semiconductor Devices

    NASA Technical Reports Server (NTRS)

    Celaya, Jose R.; Vashchenko, Vladislav; Wysocki, Philip; Saha, Sankalita

    2010-01-01

    Prognostics is an engineering discipline that focuses on estimation of the health state of a component and the prediction of its remaining useful life (RUL) before failure. Health state estimation is based on actual conditions and it is fundamental for the prediction of RUL under anticipated future usage. Failure of electronic devices is of great concern as future aircraft will see an increase of electronics to drive and control safety-critical equipment throughout the aircraft. Therefore, development of prognostics solutions for electronics is of key importance. This paper presents an accelerated aging system for gate-controlled power transistors. This system allows for the understanding of the effects of failure mechanisms, and the identification of leading indicators of failure which are essential in the development of physics-based degradation models and RUL prediction. In particular, this system isolates electrical overstress from thermal overstress. Also, this system allows for a precise control of internal temperatures, enabling the exploration of intrinsic failure mechanisms not related to the device packaging. By controlling the temperature within safe operation levels of the device, accelerated aging is induced by electrical overstress only, avoiding the generation of thermal cycles. The temperature is controlled by active thermal-electric units. Several electrical and thermal signals are measured in-situ and recorded for further analysis in the identification of leading indicators of failures. This system, therefore, provides a unique capability in the exploration of different failure mechanisms and the identification of precursors of failure that can be used to provide a health management solution for electronic devices.

  4. Tamper resistant magnetic stripes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Naylor, R.B.; Sharp, D.J.

    1999-11-09

    This invention relates to a magnetic stripe comprising a medium in which magnetized particles are suspended and in which the encoded information is recorded by actual physical rotation or alignment of the previously magnetized particles within the flux reversals of the stripe which are 180{degree} opposed in their magnetic polarity. The magnetized particles are suspended in a medium which is solid, or physically rigid, at ambient temperatures but which at moderately elevated temperatures, such as 40 C, is thinable to a viscosity permissive of rotation of the particles therein under applications of moderate external magnetic field strengths within acceptable timemore » limits.« less

  5. Ceramic tamper-revealing seals

    DOEpatents

    Kupperman, David S.; Raptis, Apostolos C.; Sheen, Shuh-Haw

    1992-01-01

    A flexible metal or ceramic cable with composite ceramic ends, or a u-shaped ceramic connecting element attached to a binding element plate or block cast from alumina or zirconium, and connected to the connecting element by shrink fitting.

  6. Ceramic tamper-revealing seals

    DOEpatents

    Kupperman, D.S.; Raptis, A.C.; Sheen, S.H.

    1992-12-08

    A flexible metal or ceramic cable is described with composite ceramic ends, or a U-shaped ceramic connecting element attached to a binding element plate or block cast from alumina or zirconium, and connected to the connecting element by shrink fitting. 7 figs.

  7. Tamper resistant magnetic stripes

    DOEpatents

    Naylor, Richard Brian; Sharp, Donald J.

    1999-01-01

    This invention relates to a magnetic stripe comprising a medium in which magnetized particles are suspended and in which the encoded information is recorded by actual physical rotation or alignment of the previously magnetized particles within the flux reversals of the stripe which are 180.degree. opposed in their magnetic polarity. The magnetized particles are suspended in a medium which is solid, or physically rigid, at ambient temperatures but which at moderately elevated temperatures, such as 40.degree. C., is thinable to a viscosity permissive of rotation of the particles therein under applications of moderate external magnetic field strengths within acceptable time limits.

  8. Use of piezoelectric multicomponent force measuring devices in fluid mechanics

    NASA Technical Reports Server (NTRS)

    Richter, A.; Stefan, K.

    1979-01-01

    The characterisitics of piezoelectric multicomponent transducers are discussed, giving attention to the advantages of quartz over other materials. The main advantage of piezoelectric devices in aerodynamic studies is their ability to indicate rapid changes in the values of physical parameters. Problems in the accuracy of measurments by piezoelectric devices can be overcome by suitable design approaches. A practical example is given of how such can be utilized to measure rapid fluctuations of fluid forces exerted on a circular cylinder mounted in a water channel.

  9. Architectures for Improved Organic Semiconductor Devices

    NASA Astrophysics Data System (ADS)

    Beck, Jonathan H.

    , semiconductors and substrates compatible with low-temperature, flexible, and oxygenated and aromatic solvent-free fabrication. Materials and processes must be capable of future high volume production in order to enable low costs. In this thesis we explore several techniques to improve organic semiconductor device performance and enable new fabrication processes. In Chapter 2, I describe the integration of sub-optical-wavelength nanostructured electrodes that improve fill factor and power conversion efficiency in organic photovoltaic devices. Photovoltaic fill factor performance is one of the primary challenges facing organic photovoltaics because most organic semiconductors have poor charge mobility. Our electrical and optical measurements and simulations indicate that nanostructured electrodes improve charge extraction in organic photovoltaics. In Chapter 3, I describe a general method for maximizing the efficiency of organic photovoltaic devices by simultaneously optimizing light absorption and charge carrier collection. We analyze the potential benefits of light trapping strategies for maximizing the overall power conversion efficiency of organic photovoltaic devices. This technique may be used to improve organic photovoltaic materials with low absorption, or short exciton diffusion and carrier-recombination lengths, opening up the device design space. In Chapter 4, I describe a process for high-quality graphene transfer onto chemically sensitive, weakly interacting organic semiconductor thin-films. Graphene is a promising flexible and highly transparent electrode for organic electronics; however, transferring graphene films onto organic semiconductor devices was previously impossible. We demonstrate a new transfer technique based on an elastomeric stamp coated with an fluorinated polymer release layer. We fabricate three classes of organic semiconductor devices: field effect transistors without high temperature annealing, transparent organic light-emitting diodes, and

  10. Exponential increase in the on-off ratio of conductance in organic memory devices by controlling the surface morphology of the devices

    NASA Astrophysics Data System (ADS)

    Vyas, Giriraj; Dagar, Parveen; Sahu, Satyajit

    2018-05-01

    We have shown an exponential increase in the ratio of conductance in the on and off states of switching devices by controlling the surface morphology of the thin films for the device by depositing at different rotational speeds. The pinholes which are preferred topography on the surface at higher rotational speed give rise to higher on-off ratio of current from the devices fabricated at the speed. The lower rotational speed contributes to higher thickness of the film and hence no switching. For thicker films, the domain is formed due to phase segregation between the two components in the film, which also indicates that the film is far from thermal equilibrium. At higher speed, there is very little scope of segregation when the film is drying up. Hence, there are only few pinholes on the surface of the film which are shallow. So, the filamentary mechanism of switching in memory devices can be firmly established by varying the speed of thin film deposition which leads to phase segregation of the materials. Thus, the formation of filament can be regulated by controlling the thickness and the surface morphology.

  11. An automated tool-joint inspection device for the drillstring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moyer, M.C.; Dale, B.A.; Kusenberger, F.N.

    1984-06-01

    This paper discusses the development of an automated tool joint inspection device-i.e., the fatigue crack detector (FCD), which can detect defects in the threaded region of drillpipe and drill collars. Inspection tests conducted at a research test facility and at drilling rig sites indicate that this device can detect both simulated defects (saw slots and drilled holes) and service-induced defects, such as fatigue cracks, pin stretch (plastic deformation), mashed threads, and corrosion pitting. The system operates on an electromagnetic-flux leakage principle and has several advantages over the conventional method of magnetic particle inspection.

  12. Medical Device Safety

    MedlinePlus

    A medical device is any product used to diagnose, cure, or treat a condition, or to prevent disease. They ... may need one in a hospital. To use medical devices safely Know how your device works. Keep ...

  13. In situ calibration of a light source in a sensor device

    DOEpatents

    Okandan, Murat; Serkland, Darwin k.; Merchant, Bion J.

    2015-12-29

    A sensor device is described herein, wherein the sensor device includes an optical measurement system, such as an interferometer. The sensor device further includes a low-power light source that is configured to emit an optical signal having a constant wavelength, wherein accuracy of a measurement output by the sensor device is dependent upon the optical signal having the constant wavelength. At least a portion of the optical signal is directed to a vapor cell, the vapor cell including an atomic species that absorbs light having the constant wavelength. A photodetector captures light that exits the vapor cell, and generates an electrical signal that is indicative of intensity of the light that exits the vapor cell. A control circuit controls operation of the light source based upon the electrical signal, such that the light source emits the optical signal with the constant wavelength.

  14. The Evolution of Devices and Systems Supporting Rehabilitation of Lower Limbs

    NASA Astrophysics Data System (ADS)

    Olinski, M.; Lewandowski, B.; Gronowicz, A.

    2015-02-01

    This paper presents the process of development, as well as examples of devices and systems supporting rehabilitation of the human lower extremities, developed independently over the years in many parts of the world. Particular emphasis was placed on indicating, which major groups of devices supporting kinesitherapy of the lower limbs can be distinguished, what are the important advantages and disadvantages of particular types of solutions, as well as what directions currently dominating in development of rehabilitation systems may be specified. A deeper analysis and comparison of several selected systems was also conducted, resulting in gathering the outcomes in two tables. They focused on a few features of mechanical design, especially the devices' kinematic structures, and devices' additional functions associated with, among others, interaction, as well as diagnosis of the limb's state and the progress of rehabilitation.

  15. A chiral-based magnetic memory device without a permanent magnet

    PubMed Central

    Dor, Oren Ben; Yochelis, Shira; Mathew, Shinto P.; Naaman, Ron; Paltiel, Yossi

    2013-01-01

    Several technologies are currently in use for computer memory devices. However, there is a need for a universal memory device that has high density, high speed and low power requirements. To this end, various types of magnetic-based technologies with a permanent magnet have been proposed. Recent charge-transfer studies indicate that chiral molecules act as an efficient spin filter. Here we utilize this effect to achieve a proof of concept for a new type of chiral-based magnetic-based Si-compatible universal memory device without a permanent magnet. More specifically, we use spin-selective charge transfer through a self-assembled monolayer of polyalanine to magnetize a Ni layer. This magnitude of magnetization corresponds to applying an external magnetic field of 0.4 T to the Ni layer. The readout is achieved using low currents. The presented technology has the potential to overcome the limitations of other magnetic-based memory technologies to allow fabricating inexpensive, high-density universal memory-on-chip devices. PMID:23922081

  16. A chiral-based magnetic memory device without a permanent magnet.

    PubMed

    Ben Dor, Oren; Yochelis, Shira; Mathew, Shinto P; Naaman, Ron; Paltiel, Yossi

    2013-01-01

    Several technologies are currently in use for computer memory devices. However, there is a need for a universal memory device that has high density, high speed and low power requirements. To this end, various types of magnetic-based technologies with a permanent magnet have been proposed. Recent charge-transfer studies indicate that chiral molecules act as an efficient spin filter. Here we utilize this effect to achieve a proof of concept for a new type of chiral-based magnetic-based Si-compatible universal memory device without a permanent magnet. More specifically, we use spin-selective charge transfer through a self-assembled monolayer of polyalanine to magnetize a Ni layer. This magnitude of magnetization corresponds to applying an external magnetic field of 0.4 T to the Ni layer. The readout is achieved using low currents. The presented technology has the potential to overcome the limitations of other magnetic-based memory technologies to allow fabricating inexpensive, high-density universal memory-on-chip devices.

  17. Evolution and update on current devices for prosthetic breast reconstruction

    PubMed Central

    2015-01-01

    Over the past decade, the leading breast reconstruction modality has shifted from autologous tissue to implants. This trend reversal is multi-factorial but includes increasing bilateral mastectomies and the more widespread acceptance of implants due to stringent quality and safety regulatory surveillance by the US Food and Drug Administration (FDA). Since 2012, the US FDA has approved several new implant styles, shapes and textures, increasing the choices for patients and surgeons. Predictable, superior aesthetic results after prosthetic breast reconstruction are attainable, but require thoughtful planning, precise surgical technique and appropriate device selection based on several different patient and surgeon parameters, such as patient desires, body mass index, breast shape, mastectomy flap quality and tissue based bio-dimensional assessment. This article briefly reviews historic devices used in prosthetic breast reconstruction beginning in the 1960s through the modern generation devices used today. We reflect on the rigorous hurdles endured over the last several decades leading to the approval of silicone gel devices, along with their well-established safety and efficacy. The various implant characteristics can affect feel and performance of the device. The many different styles and features of implants and expanders are described emphasizing surgical indications, advantages and disadvantages of each device. PMID:26005642

  18. 78 FR 34669 - Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-10

    ..., Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... importing wireless communication devices, portable music and data processing devices, and tablet computers... certain electronic devices, including wireless communication devices, portable music and data processing...

  19. "Real life" longevity of implantable cardioverter-defibrillator devices.

    PubMed

    Manolis, Antonis S; Maounis, Themistoklis; Koulouris, Spyridon; Vassilikos, Vassilios

    2017-09-01

    Manufacturers of implantable cardioverter-defibrillators (ICDs) promise a 5- to 9-year projected longevity; however, real-life data indicate otherwise. The aim of the present study was to assess ICD longevity among 685 consecutive patients over the last 20 years. Real-life longevity of ICDs may differ from that stated by the manufacturers. The study included 601 men and 84 women (mean age, 63.1 ± 13.3 years). The underlying disease was coronary (n = 396) or valvular (n = 15) disease, cardiomyopathy (n = 220), or electrical disease (n = 54). The mean ejection fraction was 35%. Devices were implanted for secondary (n = 562) or primary (n = 123) prevention. Single- (n = 292) or dual-chamber (n = 269) or cardiac resynchronization therapy (CRT) devices (n = 124) were implanted in the abdomen (n = 17) or chest (n = 668). Over 20 years, ICD pulse generator replacements were performed in 238 patients (209 men; age 63.7 ± 13.9 years; ejection fraction, 37.7% ± 14.0%) who had an ICD for secondary (n = 210) or primary (n = 28) prevention. The mean ICD longevity was 58.3 ± 18.7 months. In 20 (8.4%) patients, devices exhibited premature battery depletion within 36 months. Most (94%) patients had none, minor, or modest use of ICD therapy. Longevity was longest for single-chamber devices and shortest for CRT devices. Latest-generation devices replaced over the second decade lasted longer compared with devices replaced during the first decade. When analyzed by manufacturer, Medtronic devices appeared to have longer longevity by 13 to 18 months. ICDs continue to have limited longevity of 4.9 ± 1.6 years, and 8% demonstrate premature battery depletion by 3 years. CRT devices have the shortest longevity (mean, 3.8 years) by 13 to 17 months, compared with other ICD devices. These findings have important implications, particularly in view of the high expense involved with this type of electrical

  20. An Investigation of the Performance of Various Reaction Control Devices

    NASA Technical Reports Server (NTRS)

    Hunter, Paul A.

    1959-01-01

    An investigation of a small-scale reaction control devices in still air with both subsonic and supersonic internal flows has shown that lateral forces approaching 70 percent of the resultant force of the undeflected jet can be obtained. These results were obtained with a tilted extension at a deflection of 40 deg. The tests of tilted extensions indicated an optimum length-to-diameter ratio of approximately 0.75 to 1.00, dependent upon the deflection angle. For the two geometric types of spoiler tabs tested, blockage-area ratio appears to be the only variable affecting the lateral force developed. Usable values of lateral force were developed by the full-eyelid type of device with reasonably small losses in the thrust and weight flow. Somewhat larger values of lateral force were developed by injecting a secondary flow normal to the primary jet, but for conditions of these tests the losses in thrust and weight flow were large. Relatively good agreement with other investigations was obtained for several of the devices. The agreement of the present results with those of an investigation made with larger-scale equipment indicates that Reynolds number may not be critical for these tests. In as much as the effects of external flow could influence the performance and other factors affecting the choice of a reaction control for a specific use, it would appear desirable to make further tests of the devices described in this report in the presence of external flow.

  1. 77 FR 58576 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-21

    ... Devices, Portable Music and Data Processing Devices, Computers, and Components Thereof; Institution of... communication devices, portable music and data processing devices, computers, and components thereof by reason... certain wireless communication devices, portable music and data processing devices, computers, and...

  2. 76 FR 45860 - In the Matter of Certain Electronic Devices, Including Wireless Communication Devices, Portable...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-01

    ..., Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... electronic devices, including wireless communication devices, portable music and data processing devices, and... electronic devices, including wireless communication devices, portable music and data processing devices, and...

  3. Automated touch screen device for recording complex rodent behaviors

    PubMed Central

    Mabrouk, O.S.; Dripps, I.J.; Ramani, S.; Chang, C.; Han, J.L.; Rice, KC; Jutkiewicz, E.M.

    2016-01-01

    Background Monitoring mouse behavior is a critical step in the development of modern pharmacotherapies. New Method Here we describe the application of a novel method that utilizes a touch display computer (tablet) and software to detect, record, and report fine motor behaviors. A consumer-grade tablet device is placed in the bottom of a specially made acrylic cage allowing the animal to walk on the device (MouseTrapp). We describe its application in open field (for general locomotor studies) which measures step lengths and velocity. The device can perform light-dark (anxiety) tests by illuminating half of the screen and keeping the other half darkened. A divider is built into the lid of the device allowing the animal free access to either side. Results Treating mice with amphetamine and the delta opioid peptide receptor agonist SNC80 stimulated locomotor activity on the device. Amphetamine increased step velocity but not step length during its peak effect (40–70 min after treatment), thus indicating detection of subtle amphetamine-induced effects. Animals showed a preference (74% of time spent) for the darkened half compared to the illuminated side. Comparison with Existing Method Animals were videotaped within the chamber to compare quadrant crosses to detected motion on the device. The slope, duration and magnitude of quadrant crosses tightly correlated with overall locomotor activity as detected by Mousetrapp. Conclusions We suggest that modern touch display devices such as MouseTrapp will be an important step toward automation of behavioral analyses for characterizing phenotypes and drug effects. PMID:24952323

  4. Ion beam inertial confinement target

    DOEpatents

    Bangerter, Roger O.; Meeker, Donald J.

    1985-01-01

    A target for implosion by ion beams composed of a spherical shell of frozen DT surrounded by a low-density, low-Z pusher shell seeded with high-Z material, and a high-density tamper shell. The target has various applications in the inertial confinement technology. For certain applications, if desired, a low-density absorber shell may be positioned intermediate the pusher and tamper shells.

  5. 21 CFR 830.300 - Devices subject to device identification data submission requirements.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Devices subject to device identification data submission requirements. 830.300 Section 830.300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Identification Database § 830.300 Devices subject to device identification data submission requirements. (a) In...

  6. A Conceptual Project of a Device for Human Wrist Functional Rehabilitation

    NASA Astrophysics Data System (ADS)

    Lewandowski, B.; Olinski, M.; Wudarczyk, S.; Gronowicz, A.

    2016-12-01

    In the paper, the problems of devices supporting functional rehabilitation of a human wrist were addressed. A literature review and a description of selected devices together with an indication of their advantages and disadvantages were conducted. The biomechanical structure of a human wrist was analyzed. On this basis and after taking into consideration ranges of motion of the selected joints the concept of a new mechanism was developed. A 3D model of the device was built in the Autodesk Inventor system. For the purpose of simulations another model was developed in the MSC Adams system. Issues of drives and sensors selection, as well as requirements for the control system, were examined.

  7. Acoustic and Cavitation Fields of Shock Wave Therapy Devices

    NASA Astrophysics Data System (ADS)

    Chitnis, Parag V.; Cleveland, Robin O.

    2006-05-01

    Extracorporeal shock wave therapy (ESWT) is considered a viable treatment modality for orthopedic ailments. Despite increasing clinical use, the mechanisms by which ESWT devices generate a therapeutic effect are not yet understood. The mechanistic differences in various devices and their efficacies might be dependent on their acoustic and cavitation outputs. We report acoustic and cavitation measurements of a number of different shock wave therapy devices. Two devices were electrohydraulic: one had a large reflector (HMT Ossatron) and the other was a hand-held source (HMT Evotron); the other device was a pneumatically driven device (EMS Swiss DolorClast Vet). Acoustic measurements were made using a fiber-optic probe hydrophone and a PVDF hydrophone. A dual passive cavitation detection system was used to monitor cavitation activity. Qualitative differences between these devices were also highlighted using a high-speed camera. We found that the Ossatron generated focused shock waves with a peak positive pressure around 40 MPa. The Evotron produced peak positive pressure around 20 MPa, however, its acoustic output appeared to be independent of the power setting of the device. The peak positive pressure from the DolorClast was about 5 MPa without a clear shock front. The DolorClast did not generate a focused acoustic field. Shadowgraph images show that the wave propagating from the DolorClast is planar and not focused in the vicinity of the hand-piece. All three devices produced measurable cavitation with a characteristic time (cavitation inception to bubble collapse) that varied between 95 and 209 μs for the Ossatron, between 59 and 283 μs for the Evotron, and between 195 and 431 μs for the DolorClast. The high-speed camera images show that the cavitation activity for the DolorClast is primarily restricted to the contact surface of the hand-piece. These data indicate that the devices studied here vary in acoustic and cavitation output, which may imply that the

  8. Preloaded latching device

    NASA Technical Reports Server (NTRS)

    Wesselski, Clarence J. (Inventor); Nagy, Kornel (Inventor)

    1992-01-01

    A latching device is disclosed which is lever operated sequentially to actuate a set of collet fingers to provide a radial expansion and to actuate a force mechanism to provide a compressive gripping force for attaching first and second devices to one another. The latching device includes a body member having elongated collet fingers which, in a deactuated condition, is insertable through bores on the first and second devices so that gripping terminal portions on the collet fingers are proximate to the end of the bore of the first device while a spring assembly on the body member is located proximate to the outer surface of a second device. A lever is rotatable through 90 deg to move a latching rod to sequentially actuate and expand collet fingers and to actuate the spring assembly by compressing it. During the first 30 deg of movement of the lever, the collet fingers are actuated by the latching rod to provide a radial expansion and during the last 60 deg of movement of the lever, the spring assembly acts as a force mechanism and is actuated to develop a compressive latching force on the devices. The latching rod and lever are connected by a camming mechanism. The amount of spring force in the spring assembly can be adjusted; the body member can be permanently attached by a telescoping assembly to one of the devices; and the structure can be used as a pulling device for removing annular bearings or the like from blind bores.

  9. Tool setting device

    DOEpatents

    Brown, Raymond J.

    1977-01-01

    The present invention relates to a tool setting device for use with numerically controlled machine tools, such as lathes and milling machines. A reference position of the machine tool relative to the workpiece along both the X and Y axes is utilized by the control circuit for driving the tool through its program. This reference position is determined for both axes by displacing a single linear variable displacement transducer (LVDT) with the machine tool through a T-shaped pivotal bar. The use of the T-shaped bar allows the cutting tool to be moved sequentially in the X or Y direction for indicating the actual position of the machine tool relative to the predetermined desired position in the numerical control circuit by using a single LVDT.

  10. Sterilization of medical devices by ethylene oxide, determination of the dissipation of residues, and use of Green Fluorescent Protein as an indicator of process control.

    PubMed

    Dias, Fábio N; Ishii, Marina; Nogaroto, Sergio L; Piccini, Bruno; Penna, Thereza C V

    2009-11-01

    Ethylene oxide (EO) is used to sterilize Oxygenator and Tubing applied to heart surgery. Residual levels of EO and its derivatives, ethylene chlorohydrin (ECH) and ethylene glycol (EG), may be hazardous to the patients. Therefore, it must be removed by the aeration process. This study aimed to estimate the minimum aeration time for these devices to attain safe limits for use (avoiding excessive aeration time) and to evaluate the Green Fluorescent Protein (GFP) as a biosensor capable of best indicating the distribution and penetration of EO gas throughout the sterilization chamber. Sterilization cycles of 2, 4, and 8 h were monitored by Bacillus atrophaeus ATCC 9372 as a biological indicator (BI) and by the GFP. Residual levels of EO, ECH, and EG were determined by gas chromatography (GC), and the residual dissipation was studied. Safe limits were reached right after the sterilization process for Oxygenator and after 204 h of aeration for Tubing. In the 2 h cycle, the GFP concentration decreased from 4.8 (+/-3.2)% to 7.5 (+/-2.5)%. For the 4 h cycle, the GFP concentration decreased from 17.4 (+/-3.0)% to 21.5 (+/-6.8)%, and in the 8 h cycle, it decreased from 22.5 (+/-3.2)% to 23.9 (+/-3.9)%. This finding showed the potentiality for GFP applications as an EO biosensor.

  11. Epitaxy of advanced nanowire quantum devices

    NASA Astrophysics Data System (ADS)

    Gazibegovic, Sasa; Car, Diana; Zhang, Hao; Balk, Stijn C.; Logan, John A.; de Moor, Michiel W. A.; Cassidy, Maja C.; Schmits, Rudi; Xu, Di; Wang, Guanzhong; Krogstrup, Peter; Op Het Veld, Roy L. M.; Zuo, Kun; Vos, Yoram; Shen, Jie; Bouman, Daniël; Shojaei, Borzoyeh; Pennachio, Daniel; Lee, Joon Sue; van Veldhoven, Petrus J.; Koelling, Sebastian; Verheijen, Marcel A.; Kouwenhoven, Leo P.; Palmstrøm, Chris J.; Bakkers, Erik P. A. M.

    2017-08-01

    Semiconductor nanowires are ideal for realizing various low-dimensional quantum devices. In particular, topological phases of matter hosting non-Abelian quasiparticles (such as anyons) can emerge when a semiconductor nanowire with strong spin-orbit coupling is brought into contact with a superconductor. To exploit the potential of non-Abelian anyons—which are key elements of topological quantum computing—fully, they need to be exchanged in a well-controlled braiding operation. Essential hardware for braiding is a network of crystalline nanowires coupled to superconducting islands. Here we demonstrate a technique for generic bottom-up synthesis of complex quantum devices with a special focus on nanowire networks with a predefined number of superconducting islands. Structural analysis confirms the high crystalline quality of the nanowire junctions, as well as an epitaxial superconductor-semiconductor interface. Quantum transport measurements of nanowire ‘hashtags’ reveal Aharonov-Bohm and weak-antilocalization effects, indicating a phase-coherent system with strong spin-orbit coupling. In addition, a proximity-induced hard superconducting gap (with vanishing sub-gap conductance) is demonstrated in these hybrid superconductor-semiconductor nanowires, highlighting the successful materials development necessary for a first braiding experiment. Our approach opens up new avenues for the realization of epitaxial three-dimensional quantum architectures which have the potential to become key components of various quantum devices.

  12. Smart portable rehabilitation devices.

    PubMed

    Mavroidis, Constantinos; Nikitczuk, Jason; Weinberg, Brian; Danaher, Gil; Jensen, Katherine; Pelletier, Philip; Prugnarola, Jennifer; Stuart, Ryan; Arango, Roberto; Leahey, Matt; Pavone, Robert; Provo, Andrew; Yasevac, Dan

    2005-07-12

    The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s). In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Laboratory tests of the devices demonstrated that they were able to meet their design

  13. Smart portable rehabilitation devices

    PubMed Central

    Mavroidis, Constantinos; Nikitczuk, Jason; Weinberg, Brian; Danaher, Gil; Jensen, Katherine; Pelletier, Philip; Prugnarola, Jennifer; Stuart, Ryan; Arango, Roberto; Leahey, Matt; Pavone, Robert; Provo, Andrew; Yasevac, Dan

    2005-01-01

    Background The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s). Methods In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Results Laboratory tests of the devices demonstrated that they were able to

  14. GAS DISCHARGE DEVICES

    DOEpatents

    Arrol, W.J.; Jefferson, S.

    1957-08-27

    The construction of gas discharge devices where the object is to provide a gas discharge device having a high dark current and stabilized striking voltage is described. The inventors have discovered that the introduction of tritium gas into a discharge device with a subsequent electrical discharge in the device will deposit tritium on the inside of the chamber. The tritium acts to emit beta rays amd is an effective and non-hazardous way of improving the abovementioned discharge tube characteristics

  15. Investigation of thioglycerol stabilized ZnS quantum dots in electroluminescent device performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ethiraj, Anita Sagadevan, E-mail: anita.ethiraj@vit.ac.in; Center for Nanotechnology Research, VIT University, Vellore, TamilNadu-632014; Rhen, Dani

    2016-05-06

    The present work is focused on the investigation of thioglycerol (TG) stabilized Zinc Sulfide Quantum dots (ZnS QDs) in the hybrid electroluminescence (EL) device. Optical absorption spectroscopy clearly indicates the formation of narrow size distributed ZnS in the quantum confinement regime. X-ray Diffraction (XRD), Photoluminescence (PL), Energy Dispersive X-ray Spectroscopy (EDS) data supports the same. The hybrid EL device with structure of ITO (indium tin oxide)//PEDOT:PSS ((poly(3,4-ethylenedioxythiophene)-poly(styrene sulfonate)//HTL (α NPD- N,N′-diphenyl-N,N′-bis(1-naphthyl)-(1,1′-phenyl)-4,4′-diamine// PVK:ZnS QDs//ETL(PBD- 2-tert-butylphenyl- 5-biphenyl-1,3,4-oxadiazole)//LiF:Al (Device 1) was fabricated. Reference device without the ZnS QDs were also prepared (Device 2). The results show that the ZnS QDs based device exhibitedmore » bright electroluminescence emission of 24 cd/m{sup 2} at a driving voltage of 16 Volts under the forward bias conditions as compared to the reference device without the ZnS QDs, which showed 6 cd/m{sup 2} at ∼22 Volts.« less

  16. Indicators as Judgment Devices: An Empirical Study of Citizen Bibliometrics in Research Evaluation

    ERIC Educational Resources Information Center

    Hammarfelt, Björn; Rushforth, Alexander D.

    2017-01-01

    A researcher's number of publications has been a fundamental merit in the competition for academic positions since the late 18th century. Today, the simple counting of publications has been supplemented with a whole range of bibliometric indicators, which supposedly not only measures the volume of research but also its impact. In this study, we…

  17. Operational stability of electrophosphorescent devices containing p and n doped transport layers

    NASA Astrophysics Data System (ADS)

    D'Andrade, Brian W.; Forrest, Stephen R.; Chwang, Anna B.

    2003-11-01

    The operational stability of low-operating voltage p-i-n electrophosphorescent devices containing fac-tris(2-phenylpyridine) iridium as the emissive dopant is investigated. In these devices, Li-doped 4,7-diphenyl-1,10-phenanthroline (BPhen) served as an n-type electron transport layer, or as an undoped hole blocking layer (HBL), and 2,3,5,6-tetrafluoro-7,7,8,8-tetracyanoquinodimethane doped 4,4',4″-tris(3-methylphenylphenylamino) triphenylamine served as a p-type hole transport layer. The glass transition temperature of BPhen can be increased by the addition of aluminum(III)bis(2-methyl-8-quinolinato)4-phenylphenolate (BAlq), resulting in improved morphological stability, thereby reducing device degradation. When thermally stable BAlq was used as a HBL in both p-i-n and undoped devices, the extrapolated operational lifetime (normalized to an initial luminance of 100 cd/m2) of the p-i-n and undoped devices are 18 000 and 60 000 h, respectively, indicating that the presence of p and n dopants can accelerate device degradation.

  18. In situ KPFM imaging of local photovoltaic characteristics of structured organic photovoltaic devices.

    PubMed

    Watanabe, Satoshi; Fukuchi, Yasumasa; Fukasawa, Masako; Sassa, Takafumi; Kimoto, Atsushi; Tajima, Yusuke; Uchiyama, Masanobu; Yamashita, Takashi; Matsumoto, Mutsuyoshi; Aoyama, Tetsuya

    2014-02-12

    Here, we discuss the local photovoltaic characteristics of a structured bulk heterojunction, organic photovoltaic devices fabricated with a liquid carbazole, and a fullerene derivative based on analysis by scanning kelvin probe force microscopy (KPFM). Periodic photopolymerization induced by an interference pattern from two laser beams formed surface relief gratings (SRG) in the structured films. The surface potential distribution in the SRGs indicates the formation of donor and acceptor spatial distribution. Under illumination, the surface potential reversibly changed because of the generation of fullerene anions and hole transport from the films to substrates, which indicates that we successfully imaged the local photovoltaic characteristics of the structured photovoltaic devices. Using atomic force microscopy, we confirmed the formation of the SRG because of the material migration to the photopolymerized region of the films, which was induced by light exposure through photomasks. The structuring technique allows for the direct fabrication and the control of donor and acceptor spatial distribution in organic photonic and electronic devices with minimized material consumption. This in situ KPFM technique is indispensable to the fabrication of nanoscale electron donor and electron acceptor spatial distribution in the devices.

  19. Endoscopic placement of the small-bowel video capsule by using a capsule endoscope delivery device.

    PubMed

    Holden, Jeremy P; Dureja, Parul; Pfau, Patrick R; Schwartz, Darren C; Reichelderfer, Mark; Judd, Robert H; Danko, Istvan; Iyer, Lalitha V; Gopal, Deepak V

    2007-05-01

    Capsule endoscopy performed via the traditional peroral route is technically challenging in patients with dysphagia, gastroparesis, and/or abnormal upper-GI (UGI) anatomy. To describe the indications and outcomes of cases in which the AdvanCE capsule endoscope delivery device, which has recently been cleared by the Food and Drug Administration, was used. Retrospective, descriptive, case series. Tertiary care, university hospital. We report a case series of 16 consecutive patients in whom the AdvanCE delivery device was used. The study period was May 2005 through July 2006. Endoscopic delivery of the video capsule to the proximal small bowel by using the AdvanCE delivery device. Indications, technique, and completeness of small bowel imaging in patients who underwent endoscopic video capsule delivery. The AdvanCE delivery device was used in 16 patients ranging in age from 3 to 74 years. The primary indications for endoscopic delivery included inability to swallow the capsule (10), altered UGI anatomy (4), and gastroparesis (2). Of the 4 patients with altered UGI anatomy, 3 had dual intestinal loop anatomy (ie, Bilroth-II procedure, Whipple surgery, Roux-en-Y gastric bypass) and 1 had a failed Nissen fundoplication. In all cases, the capsule was easily deployed without complication, and complete small intestinal imaging was achieved. Small patient size. Endoscopic placement of the Given PillCam by use of the AdvanCE delivery device was safe and easily performed in patients for whom capsule endoscopy would otherwise have been contraindicated or technically challenging.

  20. Hypothesis analysis methods, hypothesis analysis devices, and articles of manufacture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanfilippo, Antonio P; Cowell, Andrew J; Gregory, Michelle L

    Hypothesis analysis methods, hypothesis analysis devices, and articles of manufacture are described according to some aspects. In one aspect, a hypothesis analysis method includes providing a hypothesis, providing an indicator which at least one of supports and refutes the hypothesis, using the indicator, associating evidence with the hypothesis, weighting the association of the evidence with the hypothesis, and using the weighting, providing information regarding the accuracy of the hypothesis.