Sample records for tandem penning trap

  1. Space-charge effects in Penning ion traps

    NASA Astrophysics Data System (ADS)

    Porobić, T.; Beck, M.; Breitenfeldt, M.; Couratin, C.; Finlay, P.; Knecht, A.; Fabian, X.; Friedag, P.; Fléchard, X.; Liénard, E.; Ban, G.; Zákoucký, D.; Soti, G.; Van Gorp, S.; Weinheimer, Ch.; Wursten, E.; Severijns, N.

    2015-06-01

    The influence of space-charge on ion cyclotron resonances and magnetron eigenfrequency in a gas-filled Penning ion trap has been investigated. Off-line measurements with K39+ using the cooling trap of the WITCH retardation spectrometer-based setup at ISOLDE/CERN were performed. Experimental ion cyclotron resonances were compared with ab initio Coulomb simulations and found to be in agreement. As an important systematic effect of the WITCH experiment, the magnetron eigenfrequency of the ion cloud was studied under increasing space-charge conditions. Finally, the helium buffer gas pressure in the Penning trap was determined by comparing experimental cooling rates with simulations.

  2. Modified Penning-Malmberg Trap for Storing Antiprotons

    NASA Technical Reports Server (NTRS)

    Sims, William H.; Martin, James; Lewis, Raymond

    2005-01-01

    A modified Penning-Malmberg trap that could store a small cloud of antiprotons for a relatively long time (weeks) has been developed. This trap is intended for use in research on the feasibility of contemplated future matter/antimatter-annihilation systems as propulsion sources for spacecraft on long missions. This trap is also of interest in its own right as a means of storing and manipulating antiprotons for terrestrial scientific experimentation. The use of Penning-Malmberg traps to store antiprotons is not new. What is new here is the modified trap design, which utilizes state-of-the-art radiofrequency (RF) techniques, including ones that, heretofore, have been used in radio-communication applications but not in iontrap applications. A basic Penning-Malmberg trap includes an evacuated round tube that contains or is surrounded by three or more collinear tube electrodes. A steady axial magnetic field that reaches a maximum at the geometric center of the tube is applied by an external source, and DC bias voltages that give rise to an electrostatic potential that reaches a minimum at the center are applied to the electrodes. The combination of electric and magnetic fields confines the charged particles (ions or electrons) for which it was designed to a prolate spheroidal central region. However, geometric misalignments and the diffusive cooling process prevent the steady fields of a basic Penning- Malmberg trap from confining the particles indefinitely. In the modified Penning-Malmberg trap, the loss of antiprotons is reduced or eliminated by use of a "rotating-wall" RF stabilization scheme that also heats the antiproton cloud to minimize loss by matter/antimatter annihilation. The scheme involves the superposition of a quadrupole electric field that rotates about the cylindrical axis at a suitably chosen radio frequency. The modified Penning-Malmberg trap (see Figure 1) includes several collinear sets of electrodes inside a tubular vacuum chamber. Each set

  3. Status and outlook of CHIP-TRAP: The Central Michigan University high precision Penning trap

    NASA Astrophysics Data System (ADS)

    Redshaw, M.; Bryce, R. A.; Hawks, P.; Gamage, N. D.; Hunt, C.; Kandegedara, R. M. E. B.; Ratnayake, I. S.; Sharp, L.

    2016-06-01

    At Central Michigan University we are developing a high-precision Penning trap mass spectrometer (CHIP-TRAP) that will focus on measurements with long-lived radioactive isotopes. CHIP-TRAP will consist of a pair of hyperbolic precision-measurement Penning traps, and a cylindrical capture/filter trap in a 12 T magnetic field. Ions will be produced by external ion sources, including a laser ablation source, and transported to the capture trap at low energies enabling ions of a given m / q ratio to be selected via their time-of-flight. In the capture trap, contaminant ions will be removed with a mass-selective rf dipole excitation and the ion of interest will be transported to the measurement traps. A phase-sensitive image charge detection technique will be used for simultaneous cyclotron frequency measurements on single ions in the two precision traps, resulting in a reduction in statistical uncertainty due to magnetic field fluctuations.

  4. Quantum mechanics in rotating-radio-frequency traps and Penning traps with a quadrupole rotating field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abe, K.; Hasegawa, T.

    2010-03-15

    Quantum-mechanical analysis of ion motion in a rotating-radio-frequency (rrf) trap or in a Penning trap with a quadrupole rotating field is carried out. Rrf traps were introduced by Hasegawa and Bollinger [Phys. Rev. A 72, 043404 (2005)]. The classical motion of a single ion in this trap is described by only trigonometric functions, whereas in the conventional linear radio-frequency (rf) traps it is by the Mathieu functions. Because of the simple classical motion in the rrf trap, it is expected that the quantum-mechanical analysis of the rrf traps is also simple compared to that of the linear rf traps. Themore » analysis of Penning traps with a quadrupole rotating field is also possible in a way similar to the rrf traps. As a result, the Hamiltonian in these traps is the same as the two-dimensional harmonic oscillator, and energy levels and wave functions are derived as exact results. In these traps, it is found that one of the vibrational modes in the rotating frame can have negative energy levels, which means that the zero-quantum-number state (''ground'' state) is the highest energy state.« less

  5. Control of the conformations of ion Coulomb crystals in a Penning trap

    PubMed Central

    Mavadia, Sandeep; Goodwin, Joseph F.; Stutter, Graham; Bharadia, Shailen; Crick, Daniel R.; Segal, Daniel M.; Thompson, Richard C.

    2013-01-01

    Laser-cooled atomic ions form ordered structures in radiofrequency ion traps and in Penning traps. Here we demonstrate in a Penning trap the creation and manipulation of a wide variety of ion Coulomb crystals formed from small numbers of ions. The configuration can be changed from a linear string, through intermediate geometries, to a planar structure. The transition from a linear string to a zigzag geometry is observed for the first time in a Penning trap. The conformations of the crystals are set by the applied trap potential and the laser parameters, and agree with simulations. These simulations indicate that the rotation frequency of a small crystal is mainly determined by the laser parameters, independent of the number of ions and the axial confinement strength. This system has potential applications for quantum simulation, quantum information processing and tests of fundamental physics models from quantum field theory to cosmology. PMID:24096901

  6. Two-species mixing in a nested Penning trap for antihydrogen trapping

    NASA Astrophysics Data System (ADS)

    Ordonez, C. A.; Weathers, D. L.

    2008-08-01

    There exists an international quest to trap neutral antimatter in the form of antihydrogen for scientific study. One method that is being developed for trapping antihydrogen employs a nested Penning trap. Such a trap serves to mix positrons and antiprotons so as to produce low energy antihydrogen atoms. Mixing is achieved when the confinement volumes of the two species overlap one another. In the work presented here, a theoretical understanding of the mixing process is developed by analyzing a mixing scheme that was recently reported [G. Gabrielse et al., Phys. Rev. Lett. 100, 113001 (2008)]. The results indicate that positron space charge or collisions among antiprotons may substantially reduce the fraction of antiprotons that have an energy suitable for antihydrogen trapping.

  7. Assembling, cleaning, and testing a unique prototype open-ended cylindrical penning trap

    NASA Astrophysics Data System (ADS)

    Marble, Kassie; Shidling, Praveen; Melconian, Dan

    2016-09-01

    A new experimental beamline containing a prototype cylindrical penning trap has recently been constructed at the Cyclotron Laboratory at Texas A&M University. The new beamline will enable precision experiments that enhance our understanding of the limits on non-SM processes in the weak interaction through the measurement of the β- ν correlation parameter for T = 2 ,0+ ->0+ supper allowed β-delayed proton emitters. The prototype TAMU TRAP consists of an open-ended cylindrical penning trap of diameter of 90 mm with gold-plated electrodes of oxygen free high conductivity copper to prevent oxidation. The trap's electric quadrupole field is provided by a SHIP TRAPS RF electronic circuit to the four segmented electrodes at the center of the trap while the trap's 7 Tesla radial magnetic field is provided by an Agilent 210 ASR magnet. A discussion of the assembly of the prototype TAMU TRAP, construction of the RF electronic circuit, the experimental set up and alignment of the beamline will be presented. The method used to test the prototype penning trap using an ion source, Faraday cups, and Micro Chanel Plate (MCP) detectors will also be discussed. Work supported by the U.S. Department of Energy under Grant No. DE-FG02-11ER41747 and the National Science Foundation.

  8. Radio-Frequency Plasma Cleaning of a Penning Malmberg Trap

    NASA Technical Reports Server (NTRS)

    Sims, William Herbert, III; Martin, James; Pearson, J. Boise; Lewis, Raymond

    2005-01-01

    Radio-frequency-generated plasma has been demonstrated to be a promising means of cleaning the interior surfaces of a Penning-Malmberg trap that is used in experiments on the confinement of antimatter. {Such a trap was reported in Modified Penning-Malmberg Trap for Storing Antiprotons (MFS-31780), NASA Tech Briefs, Vol. 29, No. 3 (March 2005), page 66.} Cleaning of the interior surfaces is necessary to minimize numbers of contaminant atoms and molecules, which reduce confinement times by engaging in matter/antimatter-annihilation reactions with confined antimatter particles. A modified Penning-Malmberg trap like the one described in the cited prior article includes several collinear ring electrodes (some of which are segmented) inside a tubular vacuum chamber, as illustrated in Figure 1. During operation of the trap, a small cloud of charged antiparticles (e.g., antiprotons or positrons) is confined to a spheroidal central region by means of a magnetic field in combination with DC and radiofrequency (RF) electric fields applied via the electrodes. In the present developmental method of cleaning by use of RF-generated plasma, one evacuates the vacuum chamber, backfills the chamber with hydrogen at a suitable low pressure, and uses an RF-signal generator and baluns to apply RF voltages to the ring electrodes. Each ring is excited in the polarity opposite that of the adjacent ring. The electric field generated by the RF signal creates a discharge in the low-pressure gas. The RF power and gas pressure are adjusted so that the plasma generated in the discharge (see Figure 2) physically and chemically attacks any solid, liquid, and gaseous contaminant layers on the electrode surfaces. The products of the physical and chemical cleaning reactions are gaseous and are removed by the vacuum pumps.

  9. A cooler Penning trap for the TITAN mass measurement facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chowdhury, U.; Kootte, B.; Good, M.

    The TITAN facility at TRIUMF makes use of highly charged ions, charge-bred in an electron beam ion trap, to carry out accurate mass measurements on radioactive isotopes. We report on our progress to develop a cooler Penning trap, CPET, which aims at reducing the energy spread of the ions to ≈ 1 eV/charge prior to injection into the mass measurement trap. In off-line mode, we can now trap electron plasmas for minutes, and we observe the damping of the m = 1 diocotron plasma mode within ≈ 2 s.

  10. TRAP: automated classification, quantification and annotation of tandemly repeated sequences.

    PubMed

    Sobreira, Tiago José P; Durham, Alan M; Gruber, Arthur

    2006-02-01

    TRAP, the Tandem Repeats Analysis Program, is a Perl program that provides a unified set of analyses for the selection, classification, quantification and automated annotation of tandemly repeated sequences. TRAP uses the results of the Tandem Repeats Finder program to perform a global analysis of the satellite content of DNA sequences, permitting researchers to easily assess the tandem repeat content for both individual sequences and whole genomes. The results can be generated in convenient formats such as HTML and comma-separated values. TRAP can also be used to automatically generate annotation data in the format of feature table and GFF files.

  11. Penning trap mass measurement of 72Br

    NASA Astrophysics Data System (ADS)

    Valverde, A. A.; Bollen, G.; Cooper, K.; Eibach, M.; Gulyuz, K.; Izzo, C.; Morrissey, D. J.; Ringle, R.; Sandler, R.; Schwarz, S.; Sumithrarachchi, C. S.; Villari, A. C. C.

    2015-03-01

    The Low Energy Beam and Ion Trap (LEBIT) Penning trap mass spectrometer was used to perform an improved-precision mass measurement of 72Br and the low-lying isomeric state, Brm72, giving mass excesses of -59 062.2 (1.0 )keV and -58 960.9 (1.2 )keV , respectively. These values are consistent with the values from the 2012 atomic mass evaluation [Chin. Phys. C 36, 1603 (2012), 10.1088/1674-1137/36/12/003] and the Nubase2012 evaluation of nuclear properties [Chin. Phys. C 36, 1157 (2012), 10.1088/1674-1137/36/12/001]. The uncertainties on the mass of the ground state and isomeric state have been reduced by a factor of seven.

  12. Micro Penning Trap for Continuous Magnetic Field Monitoring in High Radiation Environments

    NASA Astrophysics Data System (ADS)

    Latorre, Javiera; Bollen, Georg; Gulyuz, Kerim; Ringle, Ryan; Bado, Philippe; Dugan, Mark; Lebit Team; Translume Collaboration

    2016-09-01

    As new facilities for rare isotope beams, like FRIB at MSU, are constructed, there is a need for new instrumentation to monitor magnetic fields in beam magnets that can withstand the higher radiation level. Currently NMR probes, the instruments used extensively to monitor magnetic fields, do not have a long lifespans in radiation-high environments. Therefore, a radiation-hard replacement is needed. We propose to use Penning trap mass spectrometry techniques to make high precision magnetic field measurements. Our Penning microtrap will be radiation resistant as all of the vital electronics will be at a safe distance from the radiation. The trap itself is made from materials not subject to radiation damage. Penning trap mass spectrometers can determine the magnetic field by measuring the cyclotron frequency of an ion with a known mass and charge. This principle is used on the Low Energy Beam Ion Trap (LEBIT) minitrap at NSCL which is the foundation for the microtrap. We have partnered with Translume, who specialize in glass micro-fabrication, to develop a microtrap in fused-silica glass. A microtrap is finished and ready for testing at NSCL with all of the electronic and hardware components setup. DOE Phase II SBIR Award No. DE-SC0011313, NSF Award Number 1062410 REU in Physics, NSF under Grant No. PHY-1102511.

  13. Zero-point angular momentum of supersymmetric Penning trap

    NASA Astrophysics Data System (ADS)

    Zhang, Jian-zu; Xu, Qiang

    2000-10-01

    The quantum behavior of supersymmetric Penning trap, specially the superpartner of its angular momentum, is investigated in the formulation of multi-dimensional semiunitary transformation of supersymmetric quantum mechanics. In the limit case of vanishing kinetic energy it is found that its lowest angular momentum is 3ℏ/2, which provides a possibility of directly checking the idea of supersymmetric quantum mechanics and thus suggests a possible experimental verification about this prediction.

  14. A Non-Neutral Plasma Device: Electron Beam Penning Trap

    NASA Astrophysics Data System (ADS)

    Zhuang, Ge; Liu, Wan-dong; Zheng, Jian; Fu, Cheng-jiang; Bai, Bo; Chi, Ji; Zhao, Kai; Xie, Jin-lin; Liang, Xiao-ping; Yu, Chang-xuan

    1999-12-01

    An electron beam Penning trap (EBPT) non- neutral plasma system, built to investigate the formation of a dense electron core with the density beyond Brillouin limit and possible application to fusion research, has been described. The density in the center of the EBPT has been verified to be up to 10 times of Brillouin density limit.

  15. An in situ trap capacitance measurement and ion-trapping detection scheme for a Penning ion trap facility.

    PubMed

    Reza, Ashif; Banerjee, Kumardeb; Das, Parnika; Ray, Kalyankumar; Bandyopadhyay, Subhankar; Dam, Bivas

    2017-03-01

    This paper presents the design and implementation of an in situ measurement setup for the capacitance of a five electrode Penning ion trap (PIT) facility at room temperature. For implementing a high Q resonant circuit for the detection of trapped electrons/ions in a PIT, the value of the capacitance of the trap assembly is of prime importance. A tunable Colpitts oscillator followed by a unity gain buffer and a low pass filter is designed and successfully implemented for a two-fold purpose: in situ measurement of the trap capacitance when the electric and magnetic fields are turned off and also providing RF power at the desired frequency to the PIT for exciting the trapped ions and subsequent detection. The setup is tested for the in situ measurement of trap capacitance at room temperature and the results are found to comply with those obtained from measurements using a high Q parallel resonant circuit setup driven by a standard RF signal generator. The Colpitts oscillator is also tested successfully for supplying RF power to the high Q resonant circuit, which is required for the detection of trapped electrons/ions.

  16. Quantum non demolition measurement of cyclotron excitations in a Penning trap

    NASA Technical Reports Server (NTRS)

    Marzoli, Irene; Tombesi, Paolo

    1993-01-01

    The quantum non-demolition measurement of the cyclotron excitations of an electron confined in a Penning trap could be obtained by measuring the resonance frequency of the axial motion, which is coupled to the cyclotron motion through the relativistic shift of the electron mass.

  17. Technical developments for an upgrade of the LEBIT Penning trap mass spectrometry facility for rare isotopes

    NASA Astrophysics Data System (ADS)

    Redshaw, M.; Barquest, B. R.; Bollen, G.; Bustabad, S. E.; Campbell, C. M.; Ferrer, R.; Gehring, A.; Kwiatkowski, A. A.; Lincoln, D. L.; Morrissey, D. J.; Pang, G. K.; Ringle, R.; Schwarz, S.

    2011-07-01

    The LEBIT (Low Energy Beam and Ion Trap) facility is the only Penning trap mass spectrometry (PTMS) facility to utilize rare isotopes produced via fast-beam fragmentation. This technique allows access to practically all elements lighter than uranium, and in particular enables the production of isotopes that are not available or that are difficult to obtain at isotope separation on-line facilities. The preparation of the high-energy rare-isotope beam produced by projectile fragmentation for low-energy PTMS experiments is achieved by gas stopping to slow down and thermalize the fast-beam ions, along with an rf quadrupole cooler and buncher and rf quadrupole ion guides to deliver the beam to the Penning trap. During its first phase of operation LEBIT has been very successful, and new developments are now underway to access rare isotopes even farther from stability, which requires dealing with extremely short lifetimes and low production rates. These developments aim at increasing delivery efficiency, minimizing delivery and measurement time, and maximizing use of available beam time. They include an upgrade to the gas-stopping station, active magnetic field monitoring and stabilization by employing a miniature Penning trap as a magnetometer, the use of stored waveform inverse Fourier transform (SWIFT) to most effectively remove unwanted ions, and charge breeding.

  18. Penning trap mass measurement of 56Cu

    NASA Astrophysics Data System (ADS)

    Valverde, A. A.; Brodeur, M.; Bollen, G.; Eibach, M.; Gulyuz, K.; Hamacker, A.; Izzo, C.; Ong, W.-J.; Puentes, D.; Redshaw, M.; Ringle, R.; Sandler, R.; Schwarz, S.; Sumithrarachchi, C. S.; Surbrook, J.; Villari, A. C. C.; Yandow, I. T.

    2017-09-01

    The doubly-magic nucleus 56Ni is one of the most important waiting point nuclei in the rp-process. While we now know that it is not the endpoint of the rp-process, which continues to the Sn-Sb-Te cycle, the flow around this nucleus is still not well understood. A pathway bypassing 56Ni through the 55Ni(p, γ)56Cu reaction exists, but the rate depends on the Q value of this reaction, which has not been experimentally determined. Mass measurements were undertaken using the LEBIT 9.4T Penning trap mass spectrometer at the National Superconducting Cyclotron Laboratory to rectify this situation. This work was supported in part by the National Science Foundation.

  19. Status of the NIST Penning-Trap Neutron Lifetime Measurement

    NASA Astrophysics Data System (ADS)

    Snow, W. M.; Fei, X.; Chowdhuri, Z.; Dewey, M. S.; Gilliam, D.; Nico, J. S.; Greene, G. L.

    1998-10-01

    The decay rate of the free neutron is important input for Big-Bang Nucleosynthesis calculations of the primordial ^4He abundance in the universe(T. P. Walker et al, Astrophys. J. 376, 51 (1991).) and for tests of the electroweak model in the charged-current sector(I. S. Towner, Nucl. Phys. A540, 478 (1992).). We will describe an experiment in progress at NIST to measure the neutron decay rate. The technique uses a Penning trap to trap and count protons from in-beam neutron decay(J. Byrne et al., Phys. Rev. Lett. 65, 289 (1990).) and an absolutely calibrated beam monitor to measure the neutron density in the beam(R. D. Scott et al., Nucl. Inst. Meth. A362, 151 (1995).). We will present data taken in the spring and summer of 1998.

  20. Precise Penning trap measurements of double β-decay Q-values

    NASA Astrophysics Data System (ADS)

    Redshaw, M.; Brodeur, M.; Bollen, G.; Bustabad, S.; Eibach, M.; Gulyuz, K.; Izzo, C.; Lincoln, D. L.; Novario, S. J.; Ringle, R.; Sandler, R.; Schwarz, S.; Valverde, A. A.

    2015-10-01

    The double β-decay (ββ -decay) Q-value, defined as the mass difference between parent and daughter atoms, is an important parameter for both two-neutrino ββ -decay (2 νββ) and neutrinoless ββ -decay (0 νββ) experiments. The Q-value enters into the calculation of the phase space factors, which relate the measured ββ -decay half-life to the nuclear matrix element and, in the case of 0 νββ , the effective Majorana mass of the neutrino. In addition, the Q-value defines the total kinetic energy of the two electrons emitted in 0 νββ , corresponding to the location of the single peak that is the sought after signature of 0 νββ . Hence, it is essential to have a precise and accurate Q-value determination. Over the last decade, the Penning trap mass spectrometry community has made a significant effort to provide precise ββ -decay Q-value determinations. Here we report on recent measurements with the Low Energy Beam and Ion Trap (LEBIT) facility at the National Superconducting Cyclotron Laboratory (NSCL) of the 48Ca, 82Se, and 96Zr Q-values. These measurements complete the determination of ββ -decay Q-values for the 11 ``best'' candidates (those with Q >2 MeV). We also report on a measurement of the 78Kr double electron capture (2EC) Q-value and discuss ongoing Penning trap measurements relating to ββ -decay and 2EC. Support from NSF Contract No. PHY-1102511, and DOE Grant No. 03ER-41268.

  1. Shaping of nested potentials for electron cooling of highly-charged ions in a cooler Penning trap

    NASA Astrophysics Data System (ADS)

    Paul, Stefan; Kootte, Brian; Lascar, Daniel; Gwinner, Gerald; Dilling, Jens; Titan Collaboration

    2016-09-01

    TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN) is dedicated to mass spectrometry and decay spectroscopy of short-lived radioactive nuclides in a series of ion traps including a precision Penning trap. In order to boost the achievable precision of mass measurements TITAN deploys an Electron Beam Ion Trap (EBIT) providing Highly-Charged Ions (HCI). However, the charge breeding process in the EBIT leads to an increase in the ion bunch's energy spread which is detrimental to the overall precision gain. To reduce this effect a new cylindrical Cooler PEnning Trap (CPET) is being commissioned to sympathetically cool the HCI via a simultaneously trapped electron plasma. Simultaneous trapping of ions and electrons requires a high level of control over the nested potential landscape and sophisticated switching schemes for the voltages on CPET's multiple ring electrodes. For this purpose, we are currently setting up a new experimental control system for multi-channel voltage switching. The control system employs a Raspberry Pi communicating with a digital-to-analog board via a serial peripheral interface. We report on the implementation of the voltage control system and its performance with respect to electron and ion manipulation in CPET. University of British Columbia, Vancouver, BC, Canada.

  2. Measurements of Masses with the Canadian Penning Trap

    NASA Astrophysics Data System (ADS)

    Kuta, Trenton; Nystrom, Andrew; Aprahamian, Ani; Brodeur, Maxime; Burdette, Daniel; Buchinger, Fritz; Orford, Rodney; Clark, Jason; Hirsh, Tsviki; Ling-Ying, Lin; Savard, Guy; Burkey, Mary; Klimes, Jeffery; Dwaipayan, Ray; Sharma, Kumar; Morgan, Graeme

    2016-09-01

    The primary focus of the Canadian Penning Trap (CPT) located at Argonne National Laboratory is to determine the masses of various isotopes relevant to the rprocess, an astrophysical process thought to be responsible for the creation of half the elements heavier than iron. Currently, the CPT is operating in conjunction with the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) at Argonne National Laboratory's ATLAS facility in an attempt to measure neutron-rich nuclei produced by a 1.0 Curie source of 252Cf. The mass measurements of these nuclei are accomplished by measuring the cyclotron frequency of the isotopes captured in the trap. This frequency is measured with a position-sensitive microchannel plate (MCP), which records the relative position of the isotope in the trap for different phase accumulation times. This summer, the CPT group was able to successfully measure to a precision of 10 keV/c2 the masses of 142I and 156 , 158 , 159Nd, which are key nuclei needed to more accurately model the rprocess. This also marks the first time that any of these nuclei had ever been measured. This work was supported by the National Science Foundation under Contract PHY-1205412, the University of Notre Dame, and the U.S. Department of Energy, Office of Nuclear Physics, under Contract No. DE-AC02-06CH11357.

  3. Precision Penning Trap Mass Spectrometry of S, Kr and Xe

    NASA Astrophysics Data System (ADS)

    Redshaw, Matthew

    2005-04-01

    Using a phase coherent technique to measure the cyclotron frequency of single ions in a Penning trap [1], we have performed mass measurements on ^32S and the two most abundant krypton and xenon isotopes ^84Kr, ^86Kr, ^ 129Xe and ^132Xe, to relative precisions of 0.1 ppb. This is a factor of ˜10-100 improvement in precision over current values [2]. [1] M.P. Bradley, J.V. Porto, S. Rainville, J.K. Thompson, and D.E. Pritchard, PRL 83, 4510 (1999). [2] G. Audi, A.H. Wapstra, and C. Thibault, Nucl Phys A729, 337 (2003).

  4. Quantum simulation of the integer factorization problem: Bell states in a Penning trap

    NASA Astrophysics Data System (ADS)

    Rosales, Jose Luis; Martin, Vicente

    2018-03-01

    The arithmetic problem of factoring an integer N can be translated into the physics of a quantum device, a result that supports Pólya's and Hilbert's conjecture to demonstrate Riemann's hypothesis. The energies of this system, being univocally related to the factors of N , are the eigenvalues of a bounded Hamiltonian. Here we solve the quantum conditions and show that the histogram of the discrete energies, provided by the spectrum of the system, should be interpreted in number theory as the relative probability for a prime to be a factor candidate of N . This is equivalent to a quantum sieve that is shown to require only o (ln√{N}) 3 energy measurements to solve the problem, recovering Shor's complexity result. Hence the outcome can be seen as a probability map that a pair of primes solve the given factorization problem. Furthermore, we show that a possible embodiment of this quantum simulator corresponds to two entangled particles in a Penning trap. The possibility to build the simulator experimentally is studied in detail. The results show that factoring numbers, many orders of magnitude larger than those computed with experimentally available quantum computers, is achievable using typical parameters in Penning traps.

  5. Canadian Penning Trap Mass Measurements using a Position Sensitive MCP

    NASA Astrophysics Data System (ADS)

    Kuta, Trenton; Aprahamian, Ani; Marley, Scott; Nystrom, Andrew; Clark, Jason; Perez Galvan, Adrian; Hirsh, Tsviki; Savard, Guy; Orford, Rodney; Morgan, Graeme

    2015-10-01

    The primary focus of the Canadian Penning Trap (CPT) located at Argonne National Lab is to determine the masses of various isotopes produced in the spontaneous fission of Californium. Currently, the CPT is operating in conjunction with CARIBU at the ATLAS facility in an attempt to measure neutron-rich nuclei produced by a 1.5 Curie source of Californium 252. The masses of nuclei produced in fission is accomplished by measuring the cyclotron frequency of the isotopes circling within the trap. This frequency is determined by a position sensitive MCP, which records the relative position of the isotope in the trap at different times. Using these position changes over time in connection with a center spot, angles between these positions are calculated and used to determine the frequency. Most of the work currently being conducted on the CPT is focused on the precision of these frequency measurements. The use of traps has revolutionized the measurements of nuclear masses to very high precision. The optimization methods employed here include focusing the beam in order to reduce the spread on the position of the isotope as well as the tuning of the MR-ToF, a mass separator that is intended on removing contaminants in the beam. This work was supported by the nuclear Grant PHY-1419765 for the University of Notre Dame.

  6. Sideband cooling of small ion Coulomb crystals in a Penning trap

    NASA Astrophysics Data System (ADS)

    Stutter, G.; Hrmo, P.; Jarlaud, V.; Joshi, M. K.; Goodwin, J. F.; Thompson, R. C.

    2018-03-01

    We have recently demonstrated the laser cooling of a single ? ion to the motional ground state in a Penning trap using the resolved-sideband cooling technique on the electric quadrupole transition S? D?. Here we report on the extension of this technique to small ion Coulomb crystals made of two or three ? ions. Efficient cooling of the axial motion is achieved outside the Lamb-Dicke regime on a two-ion string along the magnetic field axis as well as on two- and three-ion planar crystals. Complex sideband cooling sequences are required in order to cool both axial degrees of freedom simultaneously. We measure a mean excitation after cooling of ? for the centre of mass (COM) mode and ? for the breathing mode of the two-ion string with corresponding heating rates of 11(2) ? and ? at a trap frequency of 162 kHz. The occupation of the ground state of the axial modes (?) is above 75% for the two-ion planar crystal and the associated heating rates 0.8(5) ? at a trap frequency of 355 kHz.

  7. First β-ν correlation measurement from the recoil-energy spectrum of Penning trapped Ar35 ions

    NASA Astrophysics Data System (ADS)

    Van Gorp, S.; Breitenfeldt, M.; Tandecki, M.; Beck, M.; Finlay, P.; Friedag, P.; Glück, F.; Herlert, A.; Kozlov, V.; Porobic, T.; Soti, G.; Traykov, E.; Wauters, F.; Weinheimer, Ch.; Zákoucký, D.; Severijns, N.

    2014-08-01

    We demonstrate a novel method to search for physics beyond the standard model by determining the β-ν angular correlation from the recoil-ion energy distribution after β decay of ions stored in a Penning trap. This recoil-ion energy distribution is measured with a retardation spectrometer. The unique combination of the spectrometer with a Penning trap provides a number of advantages, e.g., a high recoil-ion count rate and low sensitivity to the initial position and velocity distribution of the ions and completely different sources of systematic errors compared to other state-of-the-art experiments. Results of a first measurement with the isotope Ar35 are presented. Although currently at limited precision, we show that a statistical precision of about 0.5% is achievable with this unique method, thereby opening up the possibility of contributing to state-of-the-art searches for exotic currents in weak interactions.

  8. Hybrid dielectric light trapping designs for thin-film CdZnTe/Si tandem cells

    DOE PAGES

    Chung, H.; Zhou, C.; Tee, X. T.; ...

    2016-05-20

    Tandem solar cells consisting of high bandgap cadmium telluride alloys atop crystalline silicon have potential for high efficiencies exceeding the Shockley-Queisser limit. However, experimental results have fallen well below this goal significantly because of non-ideal current matching and light trapping. In this work, we simulate cadmium zinc telluride (CZT) and crystalline silicon (c-Si) tandems as an exemplary system to show the role that a hybrid light trapping and bandgap engineering approach can play in improving performance and lowering materials costs for tandem solar cells incorporating crystalline silicon. This work consists of two steps. First, we optimize absorption in the crystallinemore » silicon layer with front pyramidal texturing and asymmetric dielectric back gratings, which results in 121% absorption enhancement from a planar structure. Then, using this pre-optimized light trapping scheme, we model the dispersion of the Cd xZn 1-xTe alloys, and then adjust the bandgap to realize the best current matching for a range of CZT thicknesses. Using experimental parameters, the corresponding maximum efficiency is predicted to be 16.08 % for a total tandem cell thickness of only 2.2 μm.« less

  9. An ultra-stable voltage source for precision Penning-trap experiments

    NASA Astrophysics Data System (ADS)

    Böhm, Ch.; Sturm, S.; Rischka, A.; Dörr, A.; Eliseev, S.; Goncharov, M.; Höcker, M.; Ketter, J.; Köhler, F.; Marschall, D.; Martin, J.; Obieglo, D.; Repp, J.; Roux, C.; Schüssler, R. X.; Steigleder, M.; Streubel, S.; Wagner, Th.; Westermann, J.; Wieder, V.; Zirpel, R.; Melcher, J.; Blaum, K.

    2016-08-01

    An ultra-stable and low-noise 25-channel voltage source providing 0 to -100 V has been developed. It will supply stable bias potentials for Penning-trap electrodes used in high-precision experiments. The voltage source generates all its supply voltages via a specially designed transformer. Each channel can be operated either in a precision mode or can be dynamically ramped. A reference module provides reference voltages for all the channels, each of which includes a low-noise amplifier to gain a factor of 10 in the output stage. A relative voltage stability of δV / V ≈ 2 ×10-8 has been demonstrated at -89 V within about 10 min.

  10. ANALYSIS OF POLYCYCLIC AROMATIC HYDROCARBONS BY ION TRAP TANDEM MASS SPECTROMETRY

    EPA Science Inventory

    An ion-trap mass spectrometer with a wave board and tandem mass spectrometry software was used to analyze gas chromatographically separated polycyclic aromatic hydrocarbons (PAHs) by using collision-induced dissociation (CID). The nonresonant (multiple collision) mode was used to...

  11. Optical sideband spectroscopy of a single ion in a Penning trap

    NASA Astrophysics Data System (ADS)

    Mavadia, S.; Stutter, G.; Goodwin, J. F.; Crick, D. R.; Thompson, R. C.; Segal, D. M.

    2014-03-01

    We perform resolved optical sideband spectroscopy on a single 40Ca+ ion in a Penning trap. We probe the electric quadrupole allowed S1/2↔D5/2 transition at 729 nm and observe equally spaced sidebands for the three motional modes. The axial mode, parallel to the trap axis, is a one-dimensional harmonic oscillator, whereas the radial cyclotron and magnetron modes are circular motions perpendicular to the magnetic field. The total energy associated with the magnetron motion is negative, but here we probe only the (positive) kinetic energy. From the equivalent Doppler widths of the sideband spectra corresponding to the three motions we find effective temperatures of 1.1±0.2 mK, 7±3 mK, and 42±8 μK for the axial, modified cyclotron, and magnetron modes, respectively. These should be compared to the cooling limits, estimated using optimal laser parameters, of 0.38 mK, 0.8 mK, and ˜10 μK. In future work we aim to perform resolved-sideband cooling of the ion on the 729-nm transition.

  12. Rapid crystallization of externally produced ions in a Penning trap

    NASA Astrophysics Data System (ADS)

    Murböck, T.; Schmidt, S.; Birkl, G.; Nörtershäuser, W.; Thompson, R. C.; Vogel, M.

    2016-10-01

    We have studied the cooling dynamics, formation process, and geometric structure of mesoscopic crystals of externally produced magnesium ions in a Penning trap. We present a cooling model and measurements for a combination of buffer gas cooling and laser cooling which has been found to reduce the ion kinetic energy by eight orders of magnitude from several hundreds of eV to μ eV and below within seconds. With ion numbers of the order of 1 ×103 to 1 ×105 , such cooling leads to the formation of ion Coulomb crystals which display a characteristic shell structure in agreement with the theory of non-neutral plasmas. We show the production and characterization of two-species ion crystals as a means of sympathetic cooling of ions lacking a suitable laser-cooling transition.

  13. Penning Trap Experiments with the Most Exotic Nuclei on Earth: Precision Mass Measurements of Halo Nuclei

    NASA Astrophysics Data System (ADS)

    Brodeur, M.; Brunner, T.; Ettenauer, S.; Lapierre, A.; Ringle, R.; Delheij, P.; Dilling, J.

    2009-05-01

    Exotic nuclei are characterized with an extremely unbalanced protons-neutrons ratio (p/n) where for instance, the halo isotopes of He and Li have up to 3X more n than p (compared to p/n = 1 in ^12C). The properties of these exotic halo nuclei have long been recognized as the most stringent tests of our understanding of the strong force. ^11Li belongs to a special category of halos called Borromean, bound as a three-body family, while the two-body siblings, ^10Li and 2 n, are unbound as separate entities. Last year, a first mass measurement of the radioisotope ^11Li using a Penning trap spectrometer was carried out at the TITAN (Triumf's Ion Trap for Atomic and Nuclear science) facility at TRIUMF-ISAC. Penning traps are proven to be the most precise device to make mass measurements, yet until now they were unable to reach these nuclei. At TRIUMF we managed to measure the mass of ^11Li to an unprecedented precision of dm/m = 60 ppb, which is remarkable since it has a half-life of only 8.8 ms which it the shortest-lived nuclide to be measured with this technique. Furthermore, new and improved masses for the 2 and 4 n halo ^6,8He, as well has the 1 n halo ^11Be have been performed. An overview of the TITAN mass measurement program and its impact in understanding the most exotic nuclei will be given.

  14. Production of Ar{sup q+} ions with a tandem linear Paul trap

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Higaki, H., E-mail: hhigaki@hiroshima-u.ac.jp; Nagayasu, K.; Iwai, T.

    A tandem linear Paul trap was used to create highly charged Argon ions by electron impact ionizations. By improving the operation scheme, the production of Ar{sup 4+} ions was confirmed. Possible improvements for the future experiments with laser cooled Ca{sup +} ions are suggested.

  15. A 2D Array of 100's of Ions for Quantum Simulation and Many-Body Physics in a Penning Trap

    NASA Astrophysics Data System (ADS)

    Bohnet, Justin; Sawyer, Brian; Britton, Joseph; Bollinger, John

    2015-05-01

    Quantum simulations promise to reveal new materials and phenomena for experimental study, but few systems have demonstrated the capability to control ensembles in which quantum effects cannot be directly computed. One possible platform for intractable quantum simulations may be a system of 100's of 9Be+ ions in a Penning trap, where the valence electron spins are coupled with an effective Ising interaction in a 2D geometry. Here we report on results from a new Penning trap designed for 2D quantum simulations. We characterize the ion crystal stability and describe progress towards bench-marking quantum effects of the spin-spin coupling using a spin-squeezing witness. We also report on the successful photodissociation of BeH+ contaminant molecular ions that impede the use of such crystals for quantum simulation. This work lays the foundation for future experiments such as the observation of spin dynamics under the quantum Ising Hamiltonian with a transverse field. Supported by a NIST-NRC Research Associateship.

  16. Precision Penning Trap Mass Spectrometry of ^32S, ^84,86Kr and ^129,132Xe

    NASA Astrophysics Data System (ADS)

    Redshaw, Matthew

    2005-05-01

    Using a phase coherent technique to measure the cyclotron frequency of single ions in a Penning trap [1], we have performed mass measurements on ^32S and the two most abundant krypton and xenon isotopes ^84Kr, ^86Kr, ^ 129Xe and ^132Xe, to relative precisions of 0.1 ppb. This is a factor of ˜10-100 improvement in precision over current values [2]. [1] M.P. Bradley, J.V. Porto, S. Rainville, J.K. Thompson, and D.E. Pritchard, PRL 83, 4510 (1999). [2] G. Audi, A.H. Wapstra, and C. Thibault, Nucl Phys A729, 337 (2003).

  17. The new ClusterTrap setup

    NASA Astrophysics Data System (ADS)

    Martinez, F.; Marx, G.; Schweikhard, L.; Vass, A.; Ziegler, F.

    2011-07-01

    ClusterTrap has been designed to investigate properties of atomic clusters in the gas phase with particular emphasis on the dependence on the cluster size and charge state. The combination of cluster source, Penning trap and time-of-flight mass spectrometry allows a variety of experimental schemes including collision-induced dissociation, photo-dissociation, further ionization by electron impact, and electron attachment. Due to the storage capability of the trap extended-delay reaction experiments can be performed. Several recent modifications have resulted in an improved setup. In particular, an electrostatic quadrupole deflector allows the coupling of several sources or detectors to the Penning trap. Furthermore, a linear radio-frequency quadrupole trap has been added for accumulation and ion bunching and by switching the potential of a drift tube the kinetic energy of the cluster ions can be adjusted on their way towards or from the Penning trap. Recently, experiments on multiply negatively charged clusters have been resumed.

  18. Penning trap mass spectrometry Q-value determinations for highly forbidden β-decays

    NASA Astrophysics Data System (ADS)

    Sandler, Rachel; Bollen, Georg; Eibach, Martin; Gamage, Nadeesha; Gulyuz, Kerim; Hamaker, Alec; Izzo, Chris; Kandegedara, Rathnayake; Redshaw, Matt; Ringle, Ryan; Valverde, Adrian; Yandow, Isaac; Low Energy Beam Ion Trap Team

    2017-09-01

    Over the last several decades, extremely sensitive, ultra-low background beta and gamma detection techniques have been developed. These techniques have enabled the observation of very rare processes, such as highly forbidden beta decays e.g. of 113Cd, 50V and 138La. Half-life measurements of highly forbidden beta decays provide a testing ground for theoretical nuclear models, and the comparison of calculated and measured energy spectra could enable a determination of the values of the weak coupling constants. Precision Q-value measurements also allow for systematic tests of the beta-particle detection techniques. We will present the results and current status of Q value determinations for highly forbidden beta decays. The Q values, the mass difference between parent and daughter nuclides, are measured using the high precision Penning trap mass spectrometer LEBIT at the National Superconducting Cyclotron Laboratory.

  19. Development of a Tandem Electrodynamic Trap Apparatus for Merging Charged Droplets and Spectroscopic Characterization of Resultant Dried Particles.

    PubMed

    Kohno, Jun-Ya; Higashiura, Tetsu; Eguchi, Takaaki; Miura, Shumpei; Ogawa, Masato

    2016-08-11

    Materials work in multicomponent forms. A wide range of compositions must be tested to obtain the optimum composition for a specific application. We propose optimization using a series of small levitated single particles. We describe a tandem-trap apparatus for merging liquid droplets and analyzing the merged droplets and/or dried particles that are produced from the merged droplets under levitation conditions. Droplet merging was confirmed by Raman spectroscopic studies of the levitated particles. The tandem-trap apparatus enables the synthesis of a particle and spectroscopic investigation of its properties. This provides a basis for future investigation of the properties of levitated single particles.

  20. Diffractive intermediate layer enables broadband light trapping for high efficiency ultrathin c-Si tandem cells

    NASA Astrophysics Data System (ADS)

    Li, Guijun; Ho, Jacob Y. L.; Li, He; Kwok, Hoi-Sing

    2014-06-01

    Light management through the intermediate reflector in the tandem cell configuration is of great practical importance for achieving high stable efficiency and also low cost production. So far, however, the intermediate reflectors employed currently are mainly focused on the light absorption enhancement of the top cell. Here, we present a diffractive intermediate layer that allows for light trapping over a broadband wavelength for the ultrathin c-Si tandem solar cell. Compared with the standard intermediate reflector, this nanoscale architectural intermediate layer results in a 35% and 21% remarkable enhancement of the light absorption in the top (400-800 nm) and bottom (800-1100 nm) cells simultaneously, and ultrathin c-Si tandem cells with impressive conversion efficiency of 13.3% are made on the glass substrate.

  1. Phonon mediated quantum spin simulator made from a two-dimensional Wigner crystal in Penning traps

    NASA Astrophysics Data System (ADS)

    Wang, Joseph; Keith, Adam; Freericks, J. K.

    2013-03-01

    Motivated by recent advances in quantum simulations in a Penning trap, we give a theoretical description for the use of two-dimensional cold ions in a rotating trap as a quantum emulator. The collective axial phonon modes and planar modes are studied in detail, including all effects of the rotating frame. We show the character of the phonon modes and spectrum, which is crucial for engineering exotic spin interactions. In the presence of laser-ion coupling with these coherent phonon excitations, we show theoretically how the spin-spin Hamiltonian can be generated. Specifically, we notice certain parameter regimes in which the level of frustration between spins can be engineered by the coupling to the planar modes. This may be relevant to the quantum simulation of spin-glass physics or other disordered problems. This work was supported under ARO grant number W911NF0710576 with funds from the DARPA OLE Program. J. K. F. also acknowledges the McDevitt bequest at Georgetown University. A. C. K. also acknowledges support of the National Science Foundation under grant

  2. Antimatter plasmas in a multipole trap for antihydrogen.

    PubMed

    Andresen, G; Bertsche, W; Boston, A; Bowe, P D; Cesar, C L; Chapman, S; Charlton, M; Chartier, M; Deutsch, A; Fajans, J; Fujiwara, M C; Funakoshi, R; Gill, D R; Gomberoff, K; Hangst, J S; Hayano, R S; Hydomako, R; Jenkins, M J; Jørgensen, L V; Kurchaninov, L; Madsen, N; Nolan, P; Olchanski, K; Olin, A; Povilus, A; Robicheaux, F; Sarid, E; Silveira, D M; Storey, J W; Telle, H H; Thompson, R I; van der Werf, D P; Wurtele, J S; Yamazaki, Y

    2007-01-12

    We have demonstrated storage of plasmas of the charged constituents of the antihydrogen atom, antiprotons and positrons, in a Penning trap surrounded by a minimum-B magnetic trap designed for holding neutral antiatoms. The neutral trap comprises a superconducting octupole and two superconducting, solenoidal mirror coils. We have measured the storage lifetimes of antiproton and positron plasmas in the combined Penning-neutral trap, and compared these to lifetimes without the neutral trap fields. The magnetic well depth was 0.6 T, deep enough to trap ground state antihydrogen atoms of up to about 0.4 K in temperature. We have demonstrated that both particle species can be stored for times long enough to permit antihydrogen production and trapping studies.

  3. Phase space holes and synchronized BGK modes in autoresonantly driven, Penning-trapped electron clouds

    NASA Astrophysics Data System (ADS)

    Friedland, Lazar; Fajans, Joel; Bertsche, Will; Wurtele, Jonathan

    2003-10-01

    We study excitation and control of BGK modes in pure electron plasmas in a Penning trap. We apply an oscillating external potential with a negatively chirped frequency. This drive resonates with, and phase-locks to, a group of axially bouncing electrons in the trap. All initially phase-locked electrons remain phase-locked during the chirp (the autoresonance phenomenon), while some new particles are added to the resonant group, as the bucket moves through the phase space. This creates an oscillating in space and slowly evolving in energy hole in the phase space distribution of the electrons. The electron density perturbation associated with this evolving hole yields a BGK mode synchronized with the drive. The local depth of the hole in phase space, and, thus, the amplitude of the mode are controlled by the external parameter (the driving frequency). The process is reversible, so that the BGK mode can be returned to its nearly initial state, by reversing the direction of variation of the driving frequency. A kinetic theory of this excitation process is developed. The theory uses results on passage through, and capture into, bounce resonance in the system from Monte Carlo simulations of resonant bucket dynamics. We discuss the dependence of the excited BGK mode on the drive frequency chirp rate and other plasma parameters and compare these predictions with experiments.

  4. Determination of volatile organic compounds in pen inks by a dynamic headspace needle trap device combined with gas chromatography-mass spectrometry.

    PubMed

    Zang, Xiaohuan; Liang, Weiqian; Chang, Qingyun; Wu, Tong; Wang, Chun; Wang, Zhi

    2017-09-01

    Some harmful volatile organic compounds (VOCs), such as methylbenzene, ethylbenzene, xylene, chlorobenzene and bromobenzene, are the commonly found chemicals in pen inks. In this work, a dynamic headspace needle-trap device (D-HS-NTD) with a ZIF-8-derived nanoporous carbon (ZIF-8-NPC) as the adsorbent was developed for the extraction of some VOCs in different pen inks prior to GC-MS detection. The main important influencing experimental parameters including the flow rate of the purge gas N 2 , extraction temperature, extraction time, desorption temperature and desorption time for the extraction were optimized to obtain a high extraction efficiency. Under the optimized conditions, a good linearity was obtained in the concentration range of 0.1-400μgkg -1 with the correlation coefficients (r) ranging from 0.9911 to 0.9990 for the eleven VOCs. The LODs at a signal-to-noise ratio of 3 (S/N=3) were measured to be 10-20ngkg -1 for the VOCs. The developed method was applied to determine the VOCs from 20 pen inks. The recoveries of the VOCs for the method at the spiking levels of 0.5 and 20.0μgkg -1 fell in the range from 80.0% to 108%. Copyright © 2017. Published by Elsevier B.V.

  5. Developing Antimatter Containment Technology: Modeling Charged Particle Oscillations in a Penning-Malmberg Trap

    NASA Technical Reports Server (NTRS)

    Chakrabarti, S.; Martin, J. J.; Pearson, J. B.; Lewis, R. A.

    2003-01-01

    The NASA MSFC Propulsion Research Center (PRC) is conducting a research activity examining the storage of low energy antiprotons. The High Performance Antiproton Trap (HiPAT) is an electromagnetic system (Penning-Malmberg design) consisting of a 4 Tesla superconductor, a high voltage confinement electrode system, and an ultra high vacuum test section; designed with an ultimate goal of maintaining charged particles with a half-life of 18 days. Currently, this system is being experimentally evaluated using normal matter ions which are cheap to produce and relatively easy to handle and provide a good indication of overall trap behavior, with the exception of assessing annihilation losses. Computational particle-in-cell plasma modeling using the XOOPIC code is supplementing the experiments. Differing electrode voltage configurations are employed to contain charged particles, typically using flat, modified flat and harmonic potential wells. Ion cloud oscillation frequencies are obtained experimentally by amplification of signals induced on the electrodes by the particle motions. XOOPIC simulations show that for given electrode voltage configurations, the calculated charged particle oscillation frequencies are close to experimental measurements. As a two-dimensional axisymmetric code, XOOPIC cannot model azimuthal plasma variations, such as those induced by radio-frequency (RF) modulation of the central quadrupole electrode in experiments designed to enhance ion cloud containment. However, XOOPIC can model analytically varying electric potential boundary conditions and particle velocity initial conditions. Application of these conditions produces ion cloud axial and radial oscillation frequency modes of interest in achieving the goal of optimizing HiPAT for reliable containment of antiprotons.

  6. Penning-trap mass measurements of the neutron-rich K and Ca isotopes: Resurgence of the N=28 shell strength

    NASA Astrophysics Data System (ADS)

    Lapierre, A.; Brodeur, M.; Brunner, T.; Ettenauer, S.; Finlay, P.; Gallant, A. T.; Simon, V. V.; Delheij, P.; Lunney, D.; Ringle, R.; Savajols, H.; Dilling, J.

    2012-02-01

    We present Penning-trap mass measurements of neutron-rich 44,47-50K and 49,50Ca isotopes carried out at the TITAN facility at TRIUMF-ISAC. The 44K mass measurement was performed with a charge-bred 4+ ion utilizing the TITAN electron beam ion trap and agrees with the literature. The mass excesses obtained for 47K and 49,50Ca are more precise and agree with the values published in the 2003 Atomic Mass Evaluation (AME’03). The 48,49,50K mass excesses are more precise than the AME’03 values by more than 1 order of magnitude. For 48,49K, we find deviations of 7σ and 10σ, respectively. The new 49K mass excess lowers significantly the two-neutron separation energy at the neutron number N=30 compared with the separation energy calculated from the AME’03 mass-excess values and thus increases the N=28 neutron-shell gap energy at Z=19 by approximately 1 MeV.

  7. Antiproton Studies in Penning Traps

    DTIC Science & Technology

    1988-12-31

    14. SUBjeCT TERMSOS NUMBER_,Of PAGES antimatter , antiproton, trapping IL________COCK_ I?.SE -’IY- CLASSiFCAM*O fl. SECURITY CLSSIFICATIO it. SECURIT...incernational Conference on Low Energy Antimatter , Karlsruhe, GOrmlay (invited lecture) R’ NOV e 󈨝 10:59 U OF W GCS JM-Z4 PAGE.094 .... --. 89 WED er7:56 I

  8. Design and performance of an instrument for electron impact tandem mass spectrometry and action spectroscopy of mass/charge selected macromolecular ions stored in RF ion trap*

    NASA Astrophysics Data System (ADS)

    Ranković, Milos Lj.; Giuliani, Alexandre; Milosavljević, Aleksandar R.

    2016-06-01

    A new apparatus was designed, coupling an electron gun with a linear quadrupole ion trap mass spectrometer, to perform m/ z (mass over charge) selected ion activation by electron impact for tandem mass spectrometry and action spectroscopy. We present in detail electron tracing simulations of a 300 eV electron beam inside the ion trap, design of the mechanical parts, electron optics and electronic circuits used in the experiment. We also report examples of electron impact activation tandem mass spectra for Ubiquitin protein, Substance P and Melittin peptides, at incident electron energies in the range from 280 eV to 300 eV.

  9. Antiproton Studies in Penning Traps

    DTIC Science & Technology

    1993-09-30

    applications to MRI imaging. This is by far the most sensitive test of CPT invariance with a baryon system and is one of the most accurate tests of CPT...system which has likely applications to MRI imaging. This is by far the most sensitive test of CPT invariance with a baryon system and is one of the...a thin window of matter . In a second 24 hour demonstration experiment, we managed to capture a few antiprotons in the small volume of an ion trap.1

  10. Perovskite/c-Si tandem solar cell with inverted nanopyramids: realizing high efficiency by controllable light trapping

    PubMed Central

    Shi, Dai; Zeng, Yang; Shen, Wenzhong

    2015-01-01

    Perovskite/c-Si tandem solar cells (TSCs) have become a promising candidate in recent years for achieving efficiency over 30%. Although general analysis has shown very high upper limits for such TSCs, it remains largely unclear what specific optical structures could best approach these limits. Here we propose the combination of perovskite/c-Si tandem structure with inverted nanopyramid morphology as a practical way of achieving efficiency above 31% based on realistic solar cell parameters. By full-field simulation, we have shown that an ultra-low surface reflectance can be achieved by tuning the pyramid geometry within the range of experimental feasibility. More importantly, we have demonstrated that the index-guided modes can be excited within the top cell layer by introducing a TCO interlayer that prevents coupling of guided light energy into the bottom cell. This light trapping scheme has shown superior performance over the Bragg stack intermediate reflector utilized in previous micropyramid-based TSCs. Finally, by controlling the coupling between the top and bottom cell through the thickness of the interlayer, current generation within the tandem can be optimized for both two- and four-terminal configurations, yielding efficiencies of 31.9% and 32.0%, respectively. These results have provided useful guidelines for the fabrication of perovskite/c-Si TSCs. PMID:26566176

  11. Perovskite/c-Si tandem solar cell with inverted nanopyramids: realizing high efficiency by controllable light trapping.

    PubMed

    Shi, Dai; Zeng, Yang; Shen, Wenzhong

    2015-11-13

    Perovskite/c-Si tandem solar cells (TSCs) have become a promising candidate in recent years for achieving efficiency over 30%. Although general analysis has shown very high upper limits for such TSCs, it remains largely unclear what specific optical structures could best approach these limits. Here we propose the combination of perovskite/c-Si tandem structure with inverted nanopyramid morphology as a practical way of achieving efficiency above 31% based on realistic solar cell parameters. By full-field simulation, we have shown that an ultra-low surface reflectance can be achieved by tuning the pyramid geometry within the range of experimental feasibility. More importantly, we have demonstrated that the index-guided modes can be excited within the top cell layer by introducing a TCO interlayer that prevents coupling of guided light energy into the bottom cell. This light trapping scheme has shown superior performance over the Bragg stack intermediate reflector utilized in previous micropyramid-based TSCs. Finally, by controlling the coupling between the top and bottom cell through the thickness of the interlayer, current generation within the tandem can be optimized for both two- and four-terminal configurations, yielding efficiencies of 31.9% and 32.0%, respectively. These results have provided useful guidelines for the fabrication of perovskite/c-Si TSCs.

  12. Ion traps for precision experiments at rare-isotope-beam facilities

    NASA Astrophysics Data System (ADS)

    Kwiatkowski, Anna

    2016-09-01

    Ion traps first entered experimental nuclear physics when the ISOLTRAP team demonstrated Penning trap mass spectrometry of radionuclides. From then on, the demand for ion traps has grown at radioactive-ion-beam (RIB) facilities since beams can be tailored for the desired experiment. Ion traps have been deployed for beam preparation, from bunching (thereby allowing time coincidences) to beam purification. Isomerically pure beams needed for nuclear-structure investigations can be prepared for trap-assisted or in-trap decay spectroscopy. The latter permits studies of highly charged ions for stellar evolution, which would be impossible with traditional experimental nuclear-physics methods. Moreover, the textbook-like conditions and advanced ion manipulation - even of a single ion - permit high-precision experiments. Consequently, the most accurate and precise mass measurements are now performed in Penning traps. After a brief introduction to ion trapping, I will focus on examples which showcase the versatility and utility of the technique at RIB facilities. I will demonstrate how this atomic-physics technique has been integrated into nuclear science, accelerator physics, and chemistry. DOE.

  13. Cyclotron Resonance of Electrons Trapped in a Microwave Cavity

    ERIC Educational Resources Information Center

    Elmore, W. C.

    1975-01-01

    Describes an experiment in which the free-electron cyclotron resonance of electrons trapped in a microwave cavity by a Penning trap is observed. The experiment constitutes an attractive alternative to one of the Gardner-Purcell variety. (Author/GS)

  14. Shedding light on the mercury mass discrepancy by weighing Hg 52+ ions in a Penning trap

    NASA Astrophysics Data System (ADS)

    Fritioff, T.; Bluhme, H.; Schuch, R.; Bergström, I.; Björkhage, M.

    2003-07-01

    In their nuclear tables Audi and Wapstra have pointed out a serious mass discrepancy between their extrapolated values for the mercury isotopes and those from a direct measurement by the Manitoba group. The values deviate by as much as 85 ppb from each other with claimed uncertainties of about 16 and 7 ppb, respectively. In order to decide which values are correct the masses of the 198Hg and 204Hg isotopes have been measured in the Stockholm Penning trap mass spectrometer SMILETRAP using 52+ ions. This charge state corresponds to a filled Ni electron configuration for which the electron binding energy can be accurately calculated. The mass values obtained are 197.966 768 44(43) u for 198Hg and 203.973 494 10(39) u for 204Hg. These values agree with those measured by the Manitoba group, with a 3 times lower uncertainty. This measurement was made possible through the implementation of a cooling technique of the highly charged mercury ions during charge breeding in the electron beam ion source used for producing the Hg 52+ ions.

  15. Demonstration of Thermodynamics and Kinetics Using FriXion Erasable Pens

    ERIC Educational Resources Information Center

    Campbell, Dean J.; Bosma, Wayne B.; Bannon, Stephen J.; Gunter, Molly M.; Hammar, Margaret K.

    2012-01-01

    FriXion erasable pens contain thermochromic inks that have colored low-temperature forms and colorless high-temperature forms. Liquid nitrogen can be used to kinetically trap the high-temperature forms of the ink at temperatures at which ordinarily the low-temperature forms are more thermodynamically stable. (Contains 2 figures.)

  16. Physics with Trapped Antihydrogen

    NASA Astrophysics Data System (ADS)

    Charlton, Michael

    2017-04-01

    For more than a decade antihydrogen atoms have been formed by mixing antiprotons and positrons held in arrangements of charged particle (Penning) traps. More recently, magnetic minimum neutral atom traps have been superimposed upon the anti-atom production region, promoting the trapping of a small quantity of the antihydrogen yield. We will review these advances, and describe some of the first physics experiments performed on anrtihydrogen including the observation of the two-photon 1S-2S transition, invesigation of the charge neutrailty of the anti-atom and studies of the ground state hyperfine splitting. We will discuss the physics motivations for undertaking these experiments and describe some near-future initiatives.

  17. Mass Measurements of Proton-Rich Isotopes between Mo and Pd using the Canadian Penning Trap Mass Spectrometer

    NASA Astrophysics Data System (ADS)

    Fallis, J.; Sharma, K. S.; Sharma, H.; Savard, G.; Levand, A. F.; Sun, T.; Clark, J. A.; Deibel, C.; Parikh, A.; Wrede, C.; Lascar, D.; Segel, R.; Caldwell, S.; Sternberg, M.; van Schelt, J.; Buchinger, F.; Crawford, J. E.; Gulick, S.; Lee, J. K. P.; Li, G.; Scielzo, N. D.; Hecht, A. A.

    2008-04-01

    In our understanding of the origin of elemental abundances the means of producing the observed abundances of ^92Mo and ^94Mo have long been unknown. These ``light p'' nuclei cannot be adequately produced by the classic p-process alone. The νp-process however, which occurs due to the neutrino wind in core collapse supernovae explosions, involves both proton-capture and neutron-capture reactions and can produce ^92Mo and ^94Mo. The final abundances of these isotopes depend directly on the values of the proton separation energies, Sp, along the reaction path of this process. Recent mass measurements performed with the Canadian Penning Trap Mass Spectrometer have dramatically reduced the uncertainties of Sp values of proton-rich nuclei between Mo and Pd. These measurements and the resulting implications for both the νp-process path and the ^92Mo/^94Mo abundance ratio will be discussed. This work was supported by grants from NSERC, Canada and the U.S. DOE, Nucl. Phys. Div.,under Contract W-31-109-ENG-38

  18. Noncollisional kinetic model for non-neutral plasmas in a Penning trap: General properties and stationary solutions

    NASA Astrophysics Data System (ADS)

    Coppa, G. G.; Ricci, Paolo

    2002-10-01

    This work deals with a noncollisional kinetic model for non-neutral plasmas in a Penning trap. Using the spatial coordinates r, θ, z and the axial velocity vz as phase-space variables, a kinetic model is developed starting from the kinetic equation for the distribution function f(r,θ,z,vz,t). In order to reduce the complexity of the model, the kinetic equations are integrated along the axial direction by assuming an ergodic distribution in the phase space (z,vz) for particles of the same axial energy ɛ and the same planar position. In this way, a kinetic equation for the z-integrated electron distribution F(r,θ,ɛ,t) is obtained taking into account implicitly the three-dimensionality of the problem. The general properties of the model are discussed, in particular the conservation laws. The model is also related to the fluid model that was introduced by Finn et al. [Phys. Plasmas 6, 3744 (1999); Phys. Rev. Lett. 84, 2401 (2000)] and developed by Coppa et al. [Phys. Plasmas 8, 1133 (2001)]. Finally, numerical investigations are presented regarding the stationary solutions of the model.

  19. Engineered long-range interactions on a 2D array of trapped ions

    NASA Astrophysics Data System (ADS)

    Britton, Joseph W.; Sawyer, Brian C.; Bollinger, John J.; Freericks, James K.

    2014-03-01

    Ising interactions are one paradigm used to model quantum magnetism in condensed matter systems. At NIST Boulder we confine and Doppler laser cool hundreds of 9Be+ ions in a Penning trap. The valence electron of each ion behaves as an ideal spin-1/2 particle and, in the limit of weak radial confinement relative to axial confinement, the ions naturally form a two-dimensional triangular lattice. A variable-range anti-ferromagnetic Ising interaction is engineered with a spin-dependent optical dipole force (ODF) through spin-dependent excitation of collective modes of ion motion. We have also exploited this spin-dependent force to perform spectroscopy and thermometry of the normal modes of the trapped ion crystal. The high spin-count and long-range spin-spin couplings achievable in the NIST Penning trap brings within reach simulation of computationally intractable problems in quantum magnetism. Examples include modeling quantum magnetic phase transitions and propagation of spin correlations resulting from a quantum quench. The Penning system may also be amenable to observation of spin-liquid behavior thought to arise in systems where the underlying lattice structure can frustrate long-range ordering. Supported by DARPA OLE and NIST.

  20. High-precision Penning trap mass measurements of 9,10Be and the one-neutron halo nuclide 11Be

    NASA Astrophysics Data System (ADS)

    Ringle, R.; Brodeur, M.; Brunner, T.; Ettenauer, S.; Smith, M.; Lapierre, A.; Ryjkov, V. L.; Delheij, P.; Drake, G. W. F.; Lassen, J.; Lunney, D.; Dilling, J.

    2009-05-01

    Penning trap mass measurements of 9Be, 10Be (t1 / 2 = 1.51 My), and the one-neutron halo nuclide 11Be (t1 / 2 = 13.8 s) have been performed using TITAN at TRIUMF. The resulting 11Be mass excess (ME = 20 177.60 (58) keV) is in agreement with the current Atomic Mass Evaluation (AME03) [G. Audi, et al., Nucl. Phys. A 729 (2003) 337] value, but is over an order of magnitude more precise. The precision of the mass values of 9,10Be have been improved by about a factor of four and reveal a ≈ 2 σ deviation from the AME mass values. Results of new atomic physics calculations are presented for the isotope shift of 11Be relative to 9Be, and it is shown that the new mass values essentially remove atomic mass uncertainties as a contributing factor in determining the relative nuclear charge radius from the isotope shift. The new mass values of 10,11Be also allow for a more precise determination of the single-neutron binding energy of the halo neutron in 11Be.

  1. Identifying the site of spin trapping in proteins by a combination of liquid chromatography, ELISA, and off-line tandem mass spectrometry.

    PubMed

    Lardinois, Olivier M; Detweiler, Charles D; Tomer, Kenneth B; Mason, Ronald P; Deterding, Leesa J

    2008-03-01

    An off-line mass spectrometry method that combines immuno-spin trapping and chromatographic procedures has been developed for selective detection of the nitrone spin trap 5,5-dimethyl-1-pyrroline-N-oxide (DMPO) covalently attached to proteins, an attachment which occurs only subsequent to DMPO trapping of free radicals. In this technique, the protein-DMPO nitrone adducts are digested to peptides with proteolytic agents, peptides from the enzymatic digest are separated by HPLC, and enzyme-linked immunosorbent assays (ELISA) using polyclonal anti-DMPO nitrone antiserum are used to detect the eluted HPLC fractions that contain DMPO nitrone adducts. The fractions showing positive ELISA signals are then concentrated and characterized by tandem mass spectrometry (MS/MS). This method, which constitutes the first liquid chromatography-ELISA-mass spectrometry (LC-ELISA-MS)-based strategy for selective identification of DMPO-trapped protein residues in complex peptide mixtures, facilitates location and preparative fractionation of DMPO nitrone adducts for further structural characterization. The strategy is demonstrated for human hemoglobin, horse heart myoglobin, and sperm whale myoglobin, three globin proteins known to form DMPO-trappable protein radicals on treatment with H(2)O(2). The results demonstrate the power of the new experimental strategy to select DMPO-labeled peptides and identify sites of DMPO covalent attachments.

  2. Mass Spectrometry Parameters Optimization for the 46 Multiclass Pesticides Determination in Strawberries with Gas Chromatography Ion-Trap Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Fernandes, Virgínia C.; Vera, Jose L.; Domingues, Valentina F.; Silva, Luís M. S.; Mateus, Nuno; Delerue-Matos, Cristina

    2012-12-01

    Multiclass analysis method was optimized in order to analyze pesticides traces by gas chromatography with ion-trap and tandem mass spectrometry (GC-MS/MS). The influence of some analytical parameters on pesticide signal response was explored. Five ion trap mass spectrometry (IT-MS) operating parameters, including isolation time (IT), excitation voltage (EV), excitation time (ET), maximum excitation energy or " q" value (q), and isolation mass window (IMW) were numerically tested in order to maximize the instrument analytical signal response. For this, multiple linear regression was used in data analysis to evaluate the influence of the five parameters on the analytical response in the ion trap mass spectrometer and to predict its response. The assessment of the five parameters based on the regression equations substantially increased the sensitivity of IT-MS/MS in the MS/MS mode. The results obtained show that for most of the pesticides, these parameters have a strong influence on both signal response and detection limit. Using the optimized method, a multiclass pesticide analysis was performed for 46 pesticides in a strawberry matrix. Levels higher than the limit established for strawberries by the European Union were found in some samples.

  3. RF-Trapped Chip Scale Helium Ion Pump (RFT-CHIP)

    DTIC Science & Technology

    2016-04-06

    14. ABSTRACT A miniaturized (~1 cc) magnet -less RF electron trap for a helium ion pump is studied, addressing challenges associated with active...pump, ion pump, electron trap, magnet -less, MEMS, radiofrequency 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a...scale ion pumps. The Penning cell structure consists of three electrodes (an anode and two cathodes) and a magnet . Planar titanium cathodes are

  4. Quadrupole ion traps and trap arrays: geometry, material, scale, performance.

    PubMed

    Ouyang, Z; Gao, L; Fico, M; Chappell, W J; Noll, R J; Cooks, R G

    2007-01-01

    Quadrupole ion traps are reviewed, emphasizing recent developments, especially the investigation of new geometries, guided by multiple particle simulations such as the ITSIM program. These geometries include linear ion traps (LITs) and the simplified rectilinear ion trap (RIT). Various methods of fabrication are described, including the use of rapid prototyping apparatus (RPA), in which 3D objects are generated through point-by-point laser polymerization. Fabrication in silicon using multilayer semi-conductor fabrication techniques has been used to construct arrays of micro-traps. The performance of instruments containing individual traps as well as arrays of traps of various sizes and geometries is reviewed. Two types of array are differentiated. In the first type, trap arrays constitute fully multiplexed mass spectrometers in which multiple samples are examined using multiple sources, analyzers and detectors, to achieve high throughput analysis. In the second, an array of individual traps acts collectively as a composite trap to increase trapping capacity and performance for a single sample. Much progress has been made in building miniaturized mass spectrometers; a specific example is a 10 kg hand-held tandem mass spectrometer based on the RIT mass analyzer. The performance of this instrument in air and water analysis, using membrane sampling, is described.

  5. Detection of lysergic acid diethylamide (LSD) in urine by gas chromatography-ion trap tandem mass spectrometry.

    PubMed

    Sklerov, J H; Kalasinsky, K S; Ehorn, C A

    1999-10-01

    A confirmatory method for the detection and quantitation of lysergic acid diethylamide (LSD) is presented. The method employs gas chromatography-tandem mass spectrometry (GC-MS-MS) using an internal ionization ion trap detector for sensitive MS-MS-in-time measurements of LSD extracted from urine. Following a single-step solid-phase extraction of 5 mL of urine, underivatized LSD can be measured with limits of quantitation and detection of 80 and 20 pg/mL, respectively. Temperature-programmed on-column injections of urine extracts were linear over the concentration range 20-2000 pg/mL (r2 = 0.999). Intraday and interday coefficients of variation were < 6% and < 13%, respectively. This procedure has been applied to quality-control specimens and LSD-positive samples in this laboratory. Comparisons with alternate GC-MS methods and extraction procedures are discussed.

  6. Infection and mortality in captive wild-trapped canvasback ducks

    USGS Publications Warehouse

    Kocan, R.M.; Perry, M.C.

    1976-01-01

    Fungal, bacterial and malarial infections, as well as malnutrition caused heavy mortality in a group of wild-trapped canvasbacks (Aythya valisineria) held in 10 x 3 x 2 m open-water pens. Deaths occurred between 21 and 158 days after confinement and were associated with infections of Aspergillus fumigatus, Escherichia coli, Staphylococcus sp., Streptococcus sp., KlebsielIa sp., Enterobacter sp., and Plasmodium sp. Infection and mortality was believed to result from reduced resistance associated with confinement. Fourteen canvasbacks released onto large ponds survived throughout the period during which the penned birds died.

  7. High-field penning-malmberg trap: confinement properties and use in positron accumulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hartley, J.H.

    1997-09-01

    This dissertation reports on the development of the 60 kG cryogenic positron trap at Lawrence Livermore National Laboratory, and compares the trap`s confinement properties with other nonneutral plasma devices. The device is designed for the accumulation of up to 2{times}10{sup 9} positrons from a linear-accelerator source. This positron plasma could then be used in Bhabha scattering experiments. Initial efforts at time-of-flight accumulation of positrons from the accelerator show rapid ({approximately}100 ms) deconfinement, inconsistent with the long electron lifetimes. Several possible deconfinement mechanisms have been explored, including annihilation on residual gas, injection heating, rf noise from the accelerator, magnet field curvature,more » and stray fields. Detailed studies of electron confinement demonstrate that the empirical scaling law used to design the trap cannot be extrapolated into the parameter regime of this device. Several possible methods for overcoming these limitations are presented.« less

  8. Experiments Towards Mitigation of Motional Heating in Trapped Ion Quantum Information Processing

    DTIC Science & Technology

    2016-02-27

    in our surface electrode trap chips. The distance-dependence measurement was taken by Deslauri- ers et al . using a 3D needle trap [9]. These results...heating rate fit for this data is shown in Figure 6-5. 68 Delay time (ms) A ve ra ge M o ti o n al O cc u p at io n al L ev el ( ) <n...Wineland. Cooling in traps. Physica Scripta, 22:216–223, 1988 . [18] W. Itano and D. Wineland. Laser cooling of ions stored in harmonic and penning traps

  9. A high fusion power gain tandem mirror

    NASA Astrophysics Data System (ADS)

    Fowler, T. K.; Moir, R. W.; Simonen, T. C.

    2017-10-01

    Utilizing advances in high field superconducting magnet technology and microwave gyrotrons we illustrate the possibility of a high power gain (Q = 10-20) tandem mirror fusion reactor. Inspired by recent Gas Dynamic Trap (GDT) achievements we employ a simple axisymmetric mirror magnet configuration. We consider both DT and cat. DD fuel options that utilize existing as well as future technology development. We identify subjects requiring further study such as hot electron physics, trapped particle modes and plasma startup.

  10. Monolithic Perovskite Silicon Tandem Solar Cells with Advanced Optics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldschmidt, Jan C.; Bett, Alexander J.; Bivour, Martin

    2016-11-14

    For high efficiency monolithic perovskite silicon tandem solar cells, we develop low-temperature processes for the perovskite top cell, rear-side light trapping, optimized perovskite growth, transparent contacts and adapted characterization methods.

  11. Space Pens

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Fisher's Space Pen was developed for use in gravity free environments. The cartridge, pressurized with nitrogen, seals out air preventing evaporation and oxidation of the ink. Internal pressures force ink outward toward the ball point. A thixotropic ink is used. The pen will operate from minus 50 to plus 45 degrees Fahrenheit, and will withstand atmospheric extremes. It was used both on the Apollo missions and by Soviet Cosmonauts.

  12. PEN as self-vetoing structural material

    NASA Astrophysics Data System (ADS)

    Majorovits, B.; Eck, S.; Fischer, F.; Gooch, C.; Hayward, C.; Kraetzschmar, T.; van der Kolk, N.; Muenstermann, D.; Schulz, O.; Simon, F.

    2018-01-01

    Polyethylene Naphtalate (PEN) is a mechanically very favorable polymer. Earlier it was found that thin foils made from PEN can have very high radio-purity compared to other commercially available foils. In fact, PEN is already in use for low background signal transmission applications (cables). Recently it has been realized that PEN also has favorable scintillating properties. In combination, this makes PEN a very promising candidate as a self-vetoing structural material in low background experiments. Components instrumented with light detectors could be built from PEN. This includes detector holders, detector containments, signal transmission links, etc. The current R&D towards qualification of PEN as a self-vetoing low background structural material is be presented.

  13. Trapping cold ground state argon atoms.

    PubMed

    Edmunds, P D; Barker, P F

    2014-10-31

    We trap cold, ground state argon atoms in a deep optical dipole trap produced by a buildup cavity. The atoms, which are a general source for the sympathetic cooling of molecules, are loaded in the trap by quenching them from a cloud of laser-cooled metastable argon atoms. Although the ground state atoms cannot be directly probed, we detect them by observing the collisional loss of cotrapped metastable argon atoms and determine an elastic cross section. Using a type of parametric loss spectroscopy we also determine the polarizability of the metastable 4s[3/2](2) state to be (7.3±1.1)×10(-39)  C m(2)/V. Finally, Penning and associative losses of metastable atoms in the absence of light assisted collisions, are determined to be (3.3±0.8)×10(-10)  cm(3) s(-1).

  14. Squeezed coherent states of motion for ions confined in quadrupole and octupole ion traps

    NASA Astrophysics Data System (ADS)

    Mihalcea, Bogdan M.

    2018-01-01

    Quasiclassical dynamics of trapped ions is characterized by applying the time dependent variational principle (TDVP) on coherent state orbits, in case of quadrupole and octupole combined (Paul and Penning) or radiofrequency (RF) traps. A dequantization algorithm is proposed, by which the classical Hamilton (energy) function associated to the system results as the expectation value of the quantum Hamiltonian on squeezed coherent states. We develop such method and particularize the quantum Hamiltonian for both combined and RF nonlinear traps, that exhibit axial symmetry. We also build the classical Hamiltonian functions for the particular traps we considered, and find the classical equations of motion.

  15. The potential of combining ion trap/MS/MS and TOF/MS for identification of emerging contaminants

    USGS Publications Warehouse

    Ferrer, I.; Furlong, E.T.; Heine, C.E.; Thurman, E.M.

    2002-01-01

    The use of a method combining ion trap tandem mass spectrometry (MS/MS) and time of flight mass spectrometry (TOF/MS) for identification of emerging contaminates was discussed. The two tools together complemented each other in sensitivity, fragmentation and accurate mass determination. Liquid chromatography/electrospray ionization/ion-trap tandem mass spectrometry (LC/ESI/MS/MS), in positive ion mode of operation, was used to separate and identify specific compounds. Diagnostic fragment ions were obtained for a polyethyleneglycol(PEG) homolog by ion trap MS/MS, and fragments were measured by TOF/MS. It was observed that the combined method gave an exact mass measurement that differed from the calculated mass.

  16. Use of electrospray ionization ion-trap tandem mass spectrometry and principal component analysis to directly distinguish monosaccharides.

    PubMed

    Xia, Bing; Zhou, Yan; Liu, Xin; Xiao, Juan; Liu, Qing; Gu, Yucheng; Ding, Lisheng

    2012-06-15

    Carbohydrates are good source of drugs and play important roles in metabolism processes and cellular interactions in organisms. Distinguishing monosaccharide isomers in saccharide derivates is an important and elementary work in investigating saccharides. It is important to develop a fast, simple and direct method for this purpose, which is described in this study. Stock solutions of monosaccharide with a concentration of 400 μM and sodium chloride at a concentration of 10 μM were made in water/methanol (50:50, v/v). The samples were subjected to electrospray ionization ion-trap tandem mass spectrometry (ESI-MS) and the detected [2M + Na - H(2)O](+) ions were further investigated by tandem mass spectrometry (MS/MS), followed by applying principal component analysis (PCA) on the obtained MS/MS data sets. The MS/MS spectra of the [2M + Na - H(2)O](+) ions at m/z 365 for hexoses and m/z 305 for pentoses yielded unambiguous fragment patterns, while rhamnose can be directly identified by its ESI-MS [M + Na](+) ion at m/z 187. PCA showed clustering of MS/MS data of identical monosaccharide samples obtained from different experiments. By using this method, the monosaccharide in daucosterol hydrolysate was successfully identified. A new strategy was developed for differentiation of the monosaccharides using ESI-MS/MS and PCA. In MS/MS spectra, the [2M + Na - H(2)O](+) ions yielded unambiguous distinction. PCA of the archived MS/MS data sets was applied to demonstrate the spatial resolution of the studied samples. This method presented a simple and reliable way for distinguishing monosaccharides by ESI-MS/MS. Copyright © 2012 John Wiley & Sons, Ltd.

  17. A selective and sensitive method for quantitation of lysergic acid diethylamide (LSD) in whole blood by gas chromatography-ion trap tandem mass spectrometry.

    PubMed

    Libong, Danielle; Bouchonnet, Stéphane; Ricordel, Ivan

    2003-01-01

    A gas chromatography-ion trap tandem mass spectrometry (GC-ion trap MS-MS) method for detection and quantitation of LSD in whole blood is presented. The sample preparation process, including a solid-phase extraction step with Bond Elut cartridges, was performed with 2 mL of whole blood. Eight microliters of the purified extract was injected with a cold on-column injection method. Positive chemical ionization was performed using acetonitrile as reagent gas; LSD was detected in the MS-MS mode. The chromatograms obtained from blood extracts showed the great selectivity of the method. GC-MS quantitation was performed using lysergic acid methylpropylamide as the internal standard. The response of the MS was linear for concentrations ranging from 0.02 ng/mL (detection threshold) to 10.0 ng/mL. Several parameters such as the choice of the capillary column, the choice of the internal standard and that of the ionization mode (positive CI vs. EI) were rationalized. Decomposition pathways under both ionization modes were studied. Within-day and between-day stability were evaluated.

  18. The PartoPen: Using Digital Pen Technology to Improve Maternal Labor Monitoring in the Developing World

    ERIC Educational Resources Information Center

    Underwood, Heather Marie

    2013-01-01

    This dissertation presents the PartoPen, a new approach to addressing maternal labor monitoring challenges in developing countries. The PartoPen is a hardware and software system that uses digital pen technology to enhance, rather than replace, the paper-based labor monitoring tool known as the partograph. In the developing world, correct use of…

  19. Effect of pond ash on pen surface properties

    USDA-ARS?s Scientific Manuscript database

    Maintaining adequate feedlot pen surfaces is expensive. Pond ash (PA), a coal-fired electrical generation by-product, has good support qualities. A study was conducted comparing the performance of pond ash (PA) surfaced pens with soil surface (SS) pens. Four pens of an eight pen series with dimensio...

  20. Nuclear data for r-process models from ion trap measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clark, Jason, E-mail: jclark@anl.gov

    2016-06-21

    To truly understand how elements are created in the universe via the astrophysical r process, accurate nuclear data are required. Historically, the isotopes involved in the r process have been difficult to access for study, but the development of new facilities and measurement techniques have put many of the r-process isotopes within reach. This paper will discuss the new CARIBU facility at Argonne National Laboratory and two pieces of experimental equipment, the Beta-decay Paul Trap and the Canadian Penning Trap, that will dramatically increase the nuclear data available for models of the astrophysical r process.

  1. A review of 25 years' experience with the NovoPen family of insulin pens in the management of diabetes mellitus.

    PubMed

    Hyllested-Winge, Jacob; Jensen, Klaus H; Rex, Jørn

    2010-01-01

    NovoPen, the first insulin pen, was introduced in 1985. This review article is an update of a review paper published in 2006 on 20 years' use of the NovoPen family of insulin pens in the management of diabetes mellitus. The literature searches conducted in the earlier review article were updated with search results for new articles published since April 2005. This was followed by an iterative search of references cited in identified publications and by searches of abstracts from proceedings of major international diabetes conferences since 2005. Most of the original studies identified in the 2006 review showed that insulin regimens using the NovoPen family of insulin pens were at least as effective (and in some cases superior) in maintaining glycaemic control and were as safe (in terms of hypoglycaemia) as conventional insulin regimens employing vials and syringes. Most patients preferred the various NovoPen insulin pens over vials and syringes, with some evidence suggesting that the use of discreet devices, such as those of the NovoPen family, facilitates intensive insulin therapy regimens, thereby helping to improve lifestyle flexibility. The new search results showed that the current generation of the device for the adult population, NovoPen 4, retains these benefits and further meets patients' needs by improving ease of use, convenience and discretion, which may be particularly important for those with manual dexterity, visual or auditory impairments. There was also evidence that healthcare professionals would be more likely to recommend NovoPen 4 to their patients than other devices. The recently introduced NovoPen Echo, designed specifically for the paediatric population, combines half-increment dosing with a memory function that can be used to retrieve information about the time and amount of the last dose, potentially reducing the fear of double dosing or missing a dose. Evidence obtained from the new searches suggested that paediatric patients, their

  2. Vegetation survey of PEN Branch wetlands

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    A survey was conducted of vegetation along Pen Branch Creek at Savannah River Site (SRS) in support of K-Reactor restart. Plants were identified to species by overstory, understory, shrub, and groundcover strata. Abundance was also characterized and richness and diversity calculated. Based on woody species basal area, the Pen Branch delta was the most impacted, followed by the sections between the reactor and the delta. Species richness for shrub and groundcover strata were also lowest in the delta. No endangered plant species were found. Three upland pine areas were also sampled. In support of K Reactor restart, this report summarizesmore » a study of the wetland vegetation along Pen Branch. Reactor effluent enters Indian Grove Branch and then flows into Pen Branch and the Pen Branch Delta.« less

  3. Vegetation survey of PEN Branch wetlands

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-01-01

    A survey was conducted of vegetation along Pen Branch Creek at Savannah River Site (SRS) in support of K-Reactor restart. Plants were identified to species by overstory, understory, shrub, and groundcover strata. Abundance was also characterized and richness and diversity calculated. Based on woody species basal area, the Pen Branch delta was the most impacted, followed by the sections between the reactor and the delta. Species richness for shrub and groundcover strata were also lowest in the delta. No endangered plant species were found. Three upland pine areas were also sampled. In support of K Reactor restart, this report summarizesmore » a study of the wetland vegetation along Pen Branch. Reactor effluent enters Indian Grove Branch and then flows into Pen Branch and the Pen Branch Delta.« less

  4. Pen-2 overexpression induces Aβ-42 production, memory defect, motor activity enhancement and feeding behavior dysfunction in NSE/Pen-2 transgenic mice.

    PubMed

    Nam, So Hee; Seo, Su Jin; Goo, Jun Seo; Kim, Jee Eun; Choi, Sun Il; Lee, Hae Ryun; Hwang, In Sik; Jee, Seung Wan; Lee, Su Hae; Bae, Chang Jun; Park, Jung Youn; Kim, Hye Sung; Shim, Sun Bo; Hwang, Dae Youn

    2011-12-01

    Pen-2 is a key regulator of the γ-secretase complex, which is involved in the production of the amyloid β (Aβ)-42 peptides, which ultimately lead to Alzheimer's disease (AD). While Pen-2 has been studied in vitro, Pen-2 function in vivo in the brains of transgenic (Tg) mice overexpressing human Pen-2 (hPen-2) protein has not been studied. This study aimed to determine whether Pen-2 overexpression could regulate the AD-like phenotypes in Tg mice. NSE/hPen-2 Tg mice were produced by the microinjection of the NSE/hPen-2 gene into the pronucleus of fertilized eggs. The expression of the hPen-2 gene under the control of the NSE promoter was successfully detected only in the brain and kidney tissue of NSE/hPen-2 Tg mice. Also, 12-month-old NSE/hPen-2 Tg mice displayed behavioral dysfunction in the water maze test, motor activity and feeding behavior dysfunction in food intake/water intake/motor activity monitoring system. In addition, tissue samples displayed dense staining with antibody to the Aβ-42 peptide. Furthermore, NSE/hPen-2 Tg mice exhibiting feeding behavior dysfunction were significantly more apt to display symptoms related to diabetes and obesity. These results suggest that Pen-2 overexpression in NSE/hPen-2 Tg mice may induce all the AD-like phenotypes, including behavioral deficits, motor activity and feeding behavior dysfunction, Aβ-42 peptide deposition and chronic disease induction.

  5. Energy gain calculations in Penning fusion systems using a bounce-averaged Fokker-Planck model

    NASA Astrophysics Data System (ADS)

    Chacón, L.; Miley, G. H.; Barnes, D. C.; Knoll, D. A.

    2000-11-01

    In spherical Penning fusion devices, a spherical cloud of electrons, confined in a Penning-like trap, creates the ion-confining electrostatic well. Fusion energy gains for these systems have been calculated in optimistic conditions (i.e., spherically uniform electrostatic well, no collisional ion-electron interactions, single ion species) using a bounce-averaged Fokker-Planck (BAFP) model. Results show that steady-state distributions in which the Maxwellian ion population is dominant correspond to lowest ion recirculation powers (and hence highest fusion energy gains). It is also shown that realistic parabolic-like wells result in better energy gains than square wells, particularly at large well depths (>100 kV). Operating regimes with fusion power to ion input power ratios (Q-value) >100 have been identified. The effect of electron losses on the Q-value has been addressed heuristically using a semianalytic model, indicating that large Q-values are still possible provided that electron particle losses are kept small and well depths are large.

  6. Magneto-optical trapping of potassium isotopes

    NASA Astrophysics Data System (ADS)

    Williamson, Robert Sylvester, III

    1997-12-01

    We have demonstrated a magneto-optical trap (scMOT) suitable for capturing radioactive potassium produced on- line with the UW-Madison 12MeV tandem electrostatic accelerator. To do this, we made and characterized the first scMOT for potassium, measured the potassium ultracold collision rate, and developed a numerical trap- loading rate model that makes useful quantitative predictions. We have created a cold beam of collimated potassium atoms using a pyramidal magneto-optical funnel and used it to load a long-lifetime scMOT operating at ultrahigh vacuum. We have also built a target that produces a beam of radioactive 37K and 38K and coupled it to the magneto-optical funnel and trap. Once a trap of radioactive 38K has been demonstrated, the primary goal of this project is to measure the beta-asymmetry parameter in the decay of 38K, performing a sensitive test of the Standard Model of weak interactions.

  7. Lake Roosevelt Volunteer Net Pens, Lake Roosevelt Rainbow Trout Net Pens, 2002-2003 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Gene

    2003-11-01

    The completion of Grand Coulee Dam for power production, flood control, and irrigation resulted in the creation of a blocked area above the dam and in the loss of anadromous fish. Because of lake level fluctuations required to meet the demands for water release or storage, native or indigenous fish were often threatened. For many years very little effort was given to stocking the waters above the dam. However, studies by fish biologists showed that there was a good food base capable of supporting rainbow and kokanee (Gangmark and Fulton 1949, Jagielo 1984, Scholz etal 1986, Peone etal 1990). Furthermore » studies indicated that artificial production might be a way of restoring or enhancing the fishery. In the 1980's volunteers experimented with net pens. The method involved putting fingerlings in net pens in the fall and rearing them into early summer before release. The result was an excellent harvest of healthy fish. The use of net pens to hold the fingerlings for approximately nine months appears to reduce predation and the possibility of entrainment during draw down and to relieve the hatcheries to open up available raceways for future production. The volunteer net pen program grew for a few years but raising funds to maintain the pens and purchase food became more and more difficult. In 1995 the volunteer net pen project (LRDA) was awarded a grant through the Northwest Power Planning Council's artificial production provisions.« less

  8. Comparative Assessment of Lixisenatide, Exenatide, and Liraglutide Pen Devices

    PubMed Central

    Enginee, Diplom; Elton, Hina; Penfornis, Alfred; Edelman, Steve

    2014-01-01

    Background: Glucagon-like peptide-1 (GLP-1) receptor agonists are a relatively recent addition to the treatment options for type 2 diabetes mellitus (T2DM) and are administered using prefilled pen devices. Method: In this open-label task and interview-based pilot study, 3 GLP-1 receptor agonist pen devices—exenatide (Byetta®, Bristol-Myers Squibb/AstraZeneca), liraglutide (Victoza®, Novo Nordisk), and lixisenatide (Lyxumia®, Sanofi-Aventis)—were comparatively assessed in a randomized order in 30 participants with T2DM for ease of use, using a series of key performance measures (time taken to complete a series of tasks, number of user errors [successful performance], and user satisfaction rating). Linear and logistic regression analysis was conducted for the lixisenatide and liraglutide pens versus the exenatide pen. Participants’ mean age was 60 years; 27% and 20% of the participants had visual impairments and reduced manual dexterity, respectively. Results: Tasks were completed faster (P < .001) and with higher successful performance (P = .001) with the lixisenatide pen than with the exenatide pen, whereas the liraglutide pen was not statistically significant versus the exenatide pen on these parameters. Overall, user satisfaction was statistically higher for the lixisenatide and liraglutide pens versus the exenatide pen (P < .001 for both). Conclusions: Lixisenatide and liraglutide pens are associated with higher user satisfaction compared with the exenatide pen. In addition, the lixisenatide pen is faster and results in fewer errors than its comparator (exenatide). The lixisenatide pen may therefore be a suitable choice for patients with T2DM, including older and pen device-naïve patients, and those with visual impairments and reduced manual dexterity. PMID:24876548

  9. Considerations for diabetes: treatment with insulin pen devices.

    PubMed

    Cuddihy, Robert M; Borgman, Sarah K

    2013-01-01

    Insulin is essential for the treatment of type 1 diabetes, and most patients with type 2 diabetes will eventually require insulin for glycemic control. Several barriers contribute to delays in initiating insulin therapy in type 2 diabetes. Furthermore, insulin-treated patients often miss doses or otherwise fail to self-administer their insulin as prescribed, placing themselves at the risk of developing complications. Insulin pens can help overcome barriers to initiating insulin therapy and can facilitate the self-management of diabetes. Compared with the vial and syringe, insulin pens are more accurate, associated with greater adherence, and preferred by patients because of their convenience and ease of use. Large database analyses suggest that insulin pens may reduce the rate of occurrence of hypoglycemic events in patients with type 2 diabetes. Despite higher costs of insulin pens vs vials and syringes, studies suggest little or no increase in total health care costs and decreases in diabetes-related costs associated with reduced health care utilization with pens. Interestingly, the use of insulin pens within the United States lags far behind the use of pens in Europe and Japan. Insulin pens may be disposable or refillable, and some pens have special features [eg, audible clicks, large-dose selector and dial, memory function, half-unit dosing, high dosing (ie, 80 U)] that offer the opportunity to individualize treatment by meeting patients' needs. This review compares available insulin pens, describes strategies to facilitate their usage, and discusses how insulin pens can improve self-management of diabetes while reducing cost.

  10. Catalytic stereoselective synthesis of highly substituted indanones via tandem Nazarov cyclization and electrophilic fluorination trapping.

    PubMed

    Nie, Jing; Zhu, Hong-Wei; Cui, Han-Feng; Hua, Ming-Qing; Ma, Jun-An

    2007-08-02

    A new catalytic stereoselective tandem transformation via Nazarov cyclization/electrophilic fluorination has been accomplished. This sequence is efficiently catalyzed by a Cu(II) complex to afford fluorine-containing 1-indanone derivatives with two new stereocenters with high diastereoselectivity (trans/cis up to 49/1). Three examples of catalytic enantioselective tandem transformation are presented.

  11. BX-U linear trap for one-way production and confinement of Li+ and e- plasmas

    NASA Astrophysics Data System (ADS)

    Himura, Haruhiko

    2016-03-01

    A modified version of the Penning-Malmberg trap was developed wherein both positive and negative harmonic potential wells were created by using multi-ring electrodes. The sequence of particle injection, particle trapping, and plasma extraction from the potential wells was controlled by a set of switching circuits. All the guns launching charged particles were collected together in one side of the linear trap. Nevertheless, pure electron (e-) and lithium-ion (Li+) plasmas were not only separately produced on the machine axis but also confined simultaneously. Preliminary data show that for B ≈ 0.13 T the e- plasma lasted for 15 s and the Li+ plasma lasted for ~ 4 s.

  12. Differentially pumped dual linear quadrupole ion trap mass spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owen, Benjamin C.; Kenttamaa, Hilkka I.

    The present disclosure provides a new tandem mass spectrometer and methods of using the same for analyzing charged particles. The differentially pumped dual linear quadrupole ion trap mass spectrometer of the present disclose includes a combination of two linear quadrupole (LQIT) mass spectrometers with differentially pumped vacuum chambers.

  13. Tandem Carbocupration/Oxygenation of Terminal Alkynes

    PubMed Central

    Zhang, Donghui; Ready, Joseph M.

    2008-01-01

    A direct and general synthesis of α-branched aldehydes and their enol derivatives is described. Carbocupration of terminal alkynes and subsequent oxygenation with lithium tert-butyl peroxide generates a metallo-enolate. Trapping with various electrophiles provides α-branched aldehydes or stereo-defined trisubstituted enol esters or silyl ethers. The tandem carbocupration/oxygenation tolerates alkyl and silyl ethers, esters and tertiary amines. The reaction is effective with organocopper complexes derived from primary, secondary and tertiary Grignard reagents and from n-butyllithium. PMID:16321021

  14. Differentiation of regioisomeric aromatic ketocarboxylic acids by atmospheric pressure chemical ionization CAD tandem mass spectrometry in a linear quadrupole ion trap mass spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amundson, Lucas M.; Owen, Ben C.; Gallardo, Vanessa A.

    2011-01-01

    Positive-mode atmospheric pressure chemical ionization tandem mass spectrometry (APCI-MS n ) was tested for the differentiation of regioisomeric aromatic ketocarboxylic acids. Each analyte forms exclusively an abundant protonated molecule upon ionization via positive-mode APCI in a commercial linear quadrupole ion trap (LQIT) mass spectrometer. Energy-resolved collision-activated dissociation (CAD) experiments carried out on the protonated analytes revealed fragmentation patterns that varied based on the location of the functional groups. Unambiguous differentiation between the regioisomers was achieved in each case by observing different fragmentation patterns, different relative abundances of ion-molecule reaction products, or different relative abundances of fragment ions formed at differentmore » collision energies. The mechanisms of some of the reactions were examined by H/D exchange reactions and molecular orbital calculations.« less

  15. Piezoelectric sensor pen for dynamic signature verification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    EerNisse, E.P.; Land, C.E.; Snelling, J.B.

    The concept of using handwriting dynamics for electronic identification is discussed. A piezoelectric sensor pen for obtaining the pen point dynamics during writing is described. Design equations are derived and details of an operating device are presented. Typical output waveforms are shown to demonstrate the operation of the pen and to show the dissimilarities between dynamics of a genuine signature and an attempted forgery.

  16. Ion Temperature Measurements in an electron beam ion trap (EBIT)

    NASA Astrophysics Data System (ADS)

    Beiersdorfer, P.; Decaux, V.; Widmann, K.

    1997-11-01

    An electron beam ion trap consists of a Penning-type cylindrical trap traversed by a high-energy (<= 200 keV), high-density (Ne <= 10^13 cm-3) electron beam. Ions are trapped by the space charge potential of the electron beam, a static potential on the end electrodes, and a 3-T axial magnetic field [1]. The ions are heated by the electron beam and leave the trap once their kinetic energy suffices to overcome the potential barriers. Using high-resolution x-ray spectroscopy, we have made systematic measurements of the temperature of Ti^20+ and Cs^45+ ions in the trap [2]. The dependence of the ion temperature on operating parameters, such as trapping potential, beam current, and neutral gas pressure, will be presented. Temperatures as low as 15.4 ± 4.4 eV and as high as 2 keV were observed. *Work performed under the auspices of the U.S.D.o.E. by Lawrence Livermore National Laboratory under contract No. W-7405-ENG-48. [1] M. Levine et al., Phys. Scripta T22, 157 (1989). [2]P. Beiersdorfer et al., PRL 77, 5356 (1996); P. Beiersdorfer, in AIP Conf. Proc. No. 389, p. 121 (1997).

  17. Low driving voltage simplified tandem organic light-emitting devices by using exciplex-forming hosts

    NASA Astrophysics Data System (ADS)

    Zhou, Dong-Ying; Cui, Lin-Song; Zhang, Ying-Jie; Liao, Liang-Sheng; Aziz, Hany

    2014-10-01

    Tandem organic light-emitting devices (OLEDs), i.e., OLEDs containing multiple electroluminescence (EL) units that are vertically stacked, are attracting significant interest because of their ability to realize high current efficiency and long operational lifetime. However, stacking multiple EL units in tandem OLEDs increases driving voltage and complicates fabrication process relative to their standard single unit counterparts. In this paper, we demonstrate low driving voltage tandem OLEDs via utilizing exciplex-forming hosts in the EL units instead of conventional host materials. The use of exciplex-forming hosts reduces the charge injection barriers and the trapping of charges on guest molecules, resulting in the lower driving voltage. The use of exciplex-forming hosts also allows using fewer layers, hence simpler EL configuration which is beneficial for reducing the fabrication complexity of tandem OLEDs.

  18. Precise measurements of the atomic masses of silicon-28, phosphorus-31, sulfur-32, krypton-84,86, xenon-129,132,136, and the dipole moment of PH+ using single-ion and two-ion Penning trap techniques

    NASA Astrophysics Data System (ADS)

    Redshaw, Matthew

    This dissertation describes high precision measurements of atomic masses by measuring the cyclotron frequency of ions trapped singly, or in pairs, in a precision, cryogenic Penning trap. By building on techniques developed at MIT for measuring the cyclotron frequency of single trapped ions, the atomic masses of 84,86Kr, and 129,132,136Xe have been measured to less than a part in 1010 fractional precision. By developing a new technique for measuring the cyclotron frequency ratio of a pair of simultaneously trapped ions, the atomic masses of 28Si, 31P and 32S have been measured to 2 or 3 parts in 10 11. This new technique has also been used to measure the dipole moment of PH+. During the course of these measurements, two significant, but previously unsuspected sources of systematic error were discovered, characterized and eliminated. Extensive tests for other sources of systematic error were performed and are described in detail. The mass measurements presented here provide a significant increase in precision over previous values for these masses, by factors of 3 to 700. The results have a broad range of physics applications: The mass of 136 Xe is important for searches for neutrinoless double-beta-decay; the mass of 28Si is relevant to the re-definition of the artifact kilogram in terms of an atomic mass standard; the masses of 84,86Kr, and 129,132,136Xe provide convenient reference masses for less precise mass spectrometers in diverse fields such as nuclear physics and chemistry; and the dipole moment of PH+ provides a test of molecular structure calculations.

  19. Probability of detecting Porcine reproductive and respiratory syndrome virus infection using pen-based swine oral fluid specimens as a function of within-pen prevalence.

    PubMed

    Olsen, Chris; Wang, Chong; Christopher-Hennings, Jane; Doolittle, Kent; Harmon, Karen M; Abate, Sarah; Kittawornrat, Apisit; Lizano, Sergio; Main, Rodger; Nelson, Eric A; Otterson, Tracy; Panyasing, Yaowalak; Rademacher, Chris; Rauh, Rolf; Shah, Rohan; Zimmerman, Jeffrey

    2013-05-01

    Pen-based oral fluid sampling has proven to be an efficient method for surveillance of infectious diseases in swine populations. To better interpret diagnostic results, the performance of oral fluid assays (antibody- and nucleic acid-based) must be established for pen-based oral fluid samples. Therefore, the objective of the current study was to determine the probability of detecting Porcine reproductive and respiratory syndrome virus (PRRSV) infection in pen-based oral fluid samples from pens of known PRRSV prevalence. In 1 commercial swine barn, 25 pens were assigned to 1 of 5 levels of PRRSV prevalence (0%, 4%, 12%, 20%, or 36%) by placing a fixed number (0, 1, 3, 5, or 9) of PRRSV-positive pigs (14 days post PRRSV modified live virus vaccination) in each pen. Prior to placement of the vaccinated pigs, 1 oral fluid sample was collected from each pen. Thereafter, 5 oral fluid samples were collected from each pen, for a total of 150 samples. To confirm individual pig PRRSV status, serum samples from the PRRSV-negative pigs (n = 535) and the PRRSV vaccinated pigs (n = 90) were tested for PRRSV antibodies and PRRSV RNA. The 150 pen-based oral fluid samples were assayed for PRRSV antibody and PRRSV RNA at 6 laboratories. Among the 100 samples from pens containing ≥1 positive pig (≥4% prevalence) and tested at the 6 laboratories, the mean positivity was 62% for PRRSV RNA and 61% for PRRSV antibody. These results support the use of pen-based oral fluid sampling for PRRSV surveillance in commercial pig populations.

  20. Lessons Learned during the Development of HumaPen® Memoir™, an Insulin Pen with a Memory Feature

    PubMed Central

    Breslin, Stuart D.; Ignaut, Debra A.; Boyd, Douglas E.

    2010-01-01

    Insulin pens are developed to address specific needs of diabetes patients for their pens, such as ease of use, portability, and discreetness. Like many consumer-based products, the development of insulin pens can pose significant challenges to the development team in that they must balance substantial accuracy requirements with aesthetic desires. The HumaPen® Memoir™ team learned valuable lessons throughout the development process that may be worth highlighting. A keen understanding of the unmet needs of the patient population and a skillfully planned product generation map are critical to successful device development. A development team must decide whether to use a Quality Functional Deployment or system engineering-based development plan and, additionally, recognize where proof of concept ends and product development begins to maintain a strict timeline for the project. A proficiency in understanding and managing technical risk is critical to ensure a timely and high-quality product launch to the marketplace. PMID:20513318

  1. Comparing soil and pond ash feedlot pen surfaces for environmental management

    USDA-ARS?s Scientific Manuscript database

    Removing manure and replacing soil to maintain pen surfaces is expensive. Pond ash (PA), a coal-fired electrical generation by-product, has good support qualities. A study was conducted comparing the performance of pond ash (PA) surfaced pens with soil surface (SS) pens. Four pens of an eight pen se...

  2. Apertureless cantilever-free pen arrays for scanning photochemical printing.

    PubMed

    Zhou, Yu; Xie, Zhuang; Brown, Keith A; Park, Daniel J; Zhou, Xiaozhu; Chen, Peng-Cheng; Hirtz, Michael; Lin, Qing-Yuan; Dravid, Vinayak P; Schatz, George C; Zheng, Zijian; Mirkin, Chad A

    2015-02-25

    A novel, apertureless, cantilever-free pen array can be used for dual scanning photochemical and molecular printing. Serial writing with light is enabled by combining self-focusing pyramidal pens with an opaque backing between pens. The elastomeric pens also afford force-tuned illumination and simultaneous delivery of materials and optical energy. These attributes make the technique a promising candidate for maskless high-resolution photopatterning and combinatorial chemistry. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Profiling N-glycans of the egg jelly coat of the sea urchin Paracentrotus lividus by MALDI-TOF mass spectrometry and capillary liquid chromatography electrospray ionization-ion trap tandem mass spectrometry systems.

    PubMed

    Şahar, Umut; Deveci, Remziye

    2017-05-01

    Sea urchin eggs are surrounded by a carbohydrate-rich layer, termed the jelly coat, that consists of polysaccharides and glycoproteins. In the present study, we describe two mass spectrometric strategies to characterize the N-glycosylation of the Paracentrotus lividus egg jelly coat, which has an alecithal-type extracellular matrix like mammalian eggs. Egg jelly was isolated, lyophilized, and dialyzed, followed by peptide N-glycosidase F (PNGase-F) treatment to release N-glycans from their protein chain. These N-glycans were then derivatized by permethylation reaction, and analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) and capillary liquid chromatography electrospray ionization-ion trap tandem mass spectroscopy (CapLC ESI-Ion trap-MS/MS). N-glycans in the egg jelly coat glycoproteins were indicated by sodiated molecules at m/z 1579.8, 1783.9, 1988.0, 2192.0, and 2397.1 for permethylated oligosaccharides on MALDI-TOF MS. Fragmentation and structural characterization of these oligosaccharides were performed by ESI-Ion trap MS/MS. Then, MALDI-TOF-MS and ESI-Ion trap-MS/MS spectra were interpreted using the GlycoWorkbench software suite, a tool for building, displaying, and profiling glycan masses, to identify the original oligosaccharide structures. The oligosaccharides of the isolated egg jelly coat were mainly of the high mannose type. © 2017 Wiley Periodicals, Inc.

  4. Microfabricated Fountain Pens for High-Density DNA Arrays

    PubMed Central

    Reese, Matthew O.; van Dam, R. Michae; Scherer, Axel; Quake, Stephen R.

    2003-01-01

    We used photolithographic microfabrication techniques to create very small stainless steel fountain pens that were installed in place of conventional pens on a microarray spotter. Because of the small feature size produced by the microfabricated pens, we were able to print arrays with up to 25,000 spots/cm2, significantly higher than can be achieved by other deposition methods. This feature density is sufficiently large that a standard microscope slide can contain multiple replicates of every gene in a complex organism such as a mouse or human. We tested carryover during array printing with dye solution, labeled DNA, and hybridized DNA, and we found it to be indistinguishable from background. Hybridization also showed good sequence specificity to printed oligonucleotides. In addition to improved slide capacity, the microfabrication process offers the possibility of low-cost mass-produced pens and the flexibility to include novel pen features that cannot be machined with conventional techniques. PMID:12975313

  5. Trapped particle stability for the kinetic stabilizer

    NASA Astrophysics Data System (ADS)

    Berk, H. L.; Pratt, J.

    2011-08-01

    A kinetically stabilized axially symmetric tandem mirror (KSTM) uses the momentum flux of low-energy, unconfined particles that sample only the outer end-regions of the mirror plugs, where large favourable field-line curvature exists. The window of operation is determined for achieving magnetohydrodynamic (MHD) stability with tolerable energy drain from the kinetic stabilizer. Then MHD stable systems are analysed for stability of the trapped particle mode. This mode is characterized by the detachment of the central-cell plasma from the kinetic-stabilizer region without inducing field-line bending. Stability of the trapped particle mode is sensitive to the electron connection between the stabilizer and the end plug. It is found that the stability condition for the trapped particle mode is more constraining than the stability condition for the MHD mode, and it is challenging to satisfy the required power constraint. Furthermore, a severe power drain may arise from the necessary connection of low-energy electrons in the kinetic stabilizer to the central region.

  6. Characteristics of a trapped-vortex (TV) combustor

    NASA Technical Reports Server (NTRS)

    Hsu, K.-Y.; Gross, L. P.; Trump, D. D.; Roquemore, W. M.

    1994-01-01

    The characteristics of a Trapped-Vortex (TV) combustor are presented. A vortex is trapped in the cavity established between two disks mounted in tandem. Fuel and air are injected directly into the cavity in such a way as to increase the vortex strength. Some air from the annular flow is also entrained into the recirculation zone of the vortex. Lean blow-out limits of the combustor are determined for a wide range of annular air flow rates. These data indicate that the lean blow-out limits are considerably lower for the TV combustor than for flames stabilized using swirl or bluff-bodies. The pressure loss through the annular duct is also low, being less than 2% for the flow conditions in this study. The instantaneous shape of the recirculation zone of the trapped vortex is measured using a two-color PIV technique. Temperature profiles obtained with CARS indicate a well mixed recirculation zone and demonstrate the impact of primary air injection on the local equivalence ratio.

  7. Insulin pen-the "iPod" for insulin delivery (why pen wins over syringe).

    PubMed

    Asamoah, Ernest

    2008-03-01

    Diabetes affects most aspects of everyday life and places considerable responsibility on the patient; therefore, without patient acceptance of what we offer, the therapy is unlikely to be adhered to especially when that therapy happens to be insulin injection. In 2008, almost every physician/health care provider carries new and sleek cell phones (because the newer ones are well designed and function better). Why these same providers continue to prescribe insulin via syringes in 2008 is something that I cannot fathom. Previously, some insurance companies only paid for vials and there was no other choice, but today almost all insurance pay for pens and so the "insurance reason" is no longer tenable. Since Banting and Best discovered insulin in 1921, scientists have continued to improve the types of insulin (making them mimic physiology more closely in order to minimize hypoglycemia and improve glycemic control as seen with the latest analog insulins). In the same manner, the delivery process of insulin has also continued to evolve to make it easier and more acceptable to patients. Studies have shown that patients prefer device use over traditional vials/syringes. Pen devices used to inject insulin lead to better compliance, are quicker to inject, dosing is much more accurate, and, surprisingly, are more cost effective. I challenge my colleagues to take full responsibility for what their patients use. If a provider believes in pen devices, most of his/her patients will use them. The products your patients use is a direct reflection of what you practice. Educating providers to change their beliefs and practices is key to moving American diabetic patients from syringes to pen devices.

  8. Volatile Organic Compound (VOC) emissions from feedlot pen surface materials as affected by within pen location, moisture, and temperature

    USDA-ARS?s Scientific Manuscript database

    A laboratory study was conducted to evaluate the effects of pen location, moisture, and temperature on emissions of volatile organic compounds (VOC) from surface materials obtained from feedlot pens where beef cattle were fed a diet containing 30% wet distillers grain plus solubles. Surface material...

  9. Rapid separation and characterization of diterpenoid alkaloids in processed roots of Aconitum carmichaeli using ultra high performance liquid chromatography coupled with hybrid linear ion trap-Orbitrap tandem mass spectrometry.

    PubMed

    Xu, Wen; Zhang, Jing; Zhu, Dayuan; Huang, Juan; Huang, Zhihai; Bai, Junqi; Qiu, Xiaohui

    2014-10-01

    The lateral root of Aconitum carmichaeli, a popular traditional Chinese medicine, has been widely used to treat rheumatic diseases. For decades, diterpenoid alkaloids have dominated the phytochemical and biomedical research on this plant. In this study, a rapid and sensitive method based on ultra high performance liquid chromatography coupled with linear ion trap-Orbitrap tandem mass spectrometry was developed to characterize the diterpenoid alkaloids in Aconitum carmichaeli. Based on an optimized chromatographic condition, more than 120 diterpenoid alkaloids were separated with good resolution. Using a systematic strategy that combines high resolution separation, highly accurate mass measurements and a good understanding of the diagnostic fragment-based fragmentation patterns, these diterpenoid alkaloids were identified or tentatively identified. The identification of these chemicals provided essential data for further phytochemical studies and toxicity research of Aconitum carmichaeli. Moreover, the ultra high performance liquid chromatography with linear ion trap-Orbitrap mass spectrometry platform was an effective and accurate tool for rapid qualitative analysis of secondary metabolite productions from natural resources. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Motional studies of one and two laser-cooled trapped ions for electric-field sensing applications

    NASA Astrophysics Data System (ADS)

    Domínguez, F.; Gutiérrez, M. J.; Arrazola, I.; Berrocal, J.; Cornejo, J. M.; Del Pozo, J. J.; Rica, R. A.; Schmidt, S.; Solano, E.; Rodríguez, D.

    2018-03-01

    We have studied the dynamics of one and two laser-cooled trapped ?Ca? ions by applying electric fields of different nature along the axial direction of the trap, namely, driving the motion with a harmonic dipolar field, or with white noise. These two types of driving induce distinct motional states of the axial modes: a coherent oscillation with the dipolar field, or an enhanced Brownian motion due to an additional contribution to the heating rate from the electric noise. In both scenarios, the sensitivity of an isolated ion and a laser-cooled two-ion crystal has been evaluated and compared. The analysis and understanding of this dynamics is important towards the implementation of a novel Penning trap mass-spectroscopy technique based on optical detection, aiming at improving precision and sensitivity.

  11. Outbreak of diffuse lamellar keratitis caused by marking-pen toxicity.

    PubMed

    Hadden, Osmond Bruce; McGhee, Charles N J; Morris, Antony Trevor; Gray, Trevor Buchanan; Ring, Charles Peter; Watson, Adam Stewart John

    2008-07-01

    To examine the evidence that a series of cases of diffuse lamellar keratitis (DLK) after laser in situ keratomileusis (LASIK) was caused by a type of marker pen. Eye Institute, Auckland, New Zealand. During a 10-week period, 522 consecutive LASIK procedures were performed using a 60 Hz IntraLase femtosecond laser (IntraLase Corp.) to create the LASIK flap and a 217Z 100 Hz excimer laser (Bausch & Lomb) to perform the refractive ablation. As standard practice, a marking pen was used to enable accurate flap realignment. Three weeks after a sudden increase in the incidence of DLK was identified, one of the 5 surgeons performed 5 consecutive bilateral cases using the marking pen in the right eyes but not in the left eyes. Of the 522 LASIK cases (119 without marking pen, 403 with marking pen), DLK developed in 49 (9.4%). No eye treated without the marking pen developed DLK; of those in which the marking pen was used, 49 (12.2%) developed DLK (P<0.0001, Fischer exact test; odds ratio, 27). In the 5 consecutive bilateral cases in which the marking pen was used in the right eye but not the left eye, 4 right eyes and no left eye developed DLK (P=0.03). Forty-five of the 49 eyes with DLK quickly recovered. The other 4 developed central toxic keratopathy. There is strong statistical evidence that the marking pen was a factor in the occurrence of DLK.

  12. Volatile organic compound (VOC) emissions from beef feedlot pen surface as affected by within pen location, moisture, and temperature

    USDA-ARS?s Scientific Manuscript database

    A laboratory study was conducted to determine effects of pen location, moisture, and temperature on emissions of volatile organic compounds (VOC). Feedlot surface material (FSM) was obtained from pens where cattle were fed a diet containing 30% wet distillers grain plus soluble (WDGS). The FSM were ...

  13. Review of Plasma Techniques Used to Trap Antihydrogen

    NASA Astrophysics Data System (ADS)

    Fajans, Joel

    2011-10-01

    Recently, the ALPHA collaboration at CERN trapped antihydrogen atoms. To date, over three hundred antiatoms have been confined, some for as long as 1000s. This was the first time that antiatoms had ever been trapped. The ultimate goal of the ALPHA collaboration is to test CPT invariance by comparing the spectra of hydrogen and antihydrogen, and to measure the gravitational attraction between matter and antimatter. Such studies might resolve the baryogenesis problem: why is there very little antimatter in the Universe? The ALPHA experiment brought together techniques from many different fields of physics, but the crucial breakthroughs were in plasma physics. The essential problem is this: How does one combine two Malmberg-Penning trapped plasmas, one made from antiprotons, and the other positrons, which have opposite electrostatic potentials of nearly one volt, in such a manner that the antiprotons traverse the positrons with kinetic energies of less than 40 μeV, this latter being the depth of the superimposed neutral antihydrogen trap? The plasma techniques ALPHA developed to accomplish this include: Minimizing the effects of the neutral trap multipole fields on the positron and antiproton plasma confinement. Compressing antiprotons down to less than 0.5mm. Using autoresonance to inject antiprotons into the positrons with very little excess energy. Evaporative cooling of the electrons and antiprotons to record low temperatures. Development of charge, radial profile, temperature, and antiproton loss location diagnostics. Careful and lengthy manipulations to finesse the plasmas into the best states for optimal antihydrogen production and trapping. The plasma techniques necessary to trap antihydrogen will be reviewed in this talk. This work was supported by DOE and NSF, and is reported on behalf of the ALPHA collaboration.

  14. The EChemPen: A Guiding Hand to Learn Electrochemical Surface Modifications

    ERIC Educational Resources Information Center

    Valetaud, Mathieu; Loget, Gabriel; Roche, Je´rome; Hu¨sken, Nina; Fattah, Zahra; Badets, Vasilica; Fontaine, Olivier; Zigah, Dodzi

    2015-01-01

    The Electrochemical Pen (EChemPen) was developed as an attractive tool for learning electrochemistry. The fabrication, principle, and operation of the EChemPen are simple and can be easily performed by students in practical classes. It is based on a regular fountain pen principle, where the electrolytic solution is dispensed at a tip to locally…

  15. A rare-earth-magnet ion trap for confining low-Z, bare nuclei

    NASA Astrophysics Data System (ADS)

    Brewer, Samuel M.; Tan, Joseph N.

    2009-05-01

    Simplifications in the theory for Rydberg states of hydrogenlike ions allow a substantial improvement in the accuracy of predicted levels, which can yield information on the values of fundamental constants and test theory if they can be compared with precision frequency measurements.[1] We consider the trapping of bare nuclei (fully-stripped) to be used in making Rydberg states of one-electron ions with atomic number 1< Z < 11. Numerical simulation is used here to study ion confinement in a compact, Penning-style ion trap consisting of electrodes integrated with rare-earth permanent magnets, and to model the capture of charge-state-selected ions extracted from an electron beam ion trap (EBIT). An experimental apparatus adapted to the NIST EBIT will also be discussed. Reference: [1] U.D. Jentschura, P.J. Mohr, J.N. Tan, and B.J. Wundt, ``Fundamental constants and tests of theory in Rydberg states of hydrogenlike ions,'' Phys. Rev. Lett. 100, 160404 (2008).

  16. Extending the applicability of an open-ring trap to perform experiments with a single laser-cooled ion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cornejo, J. M.; Colombano, M.; Doménech, J.

    A special ion trap was initially built up to perform β-ν correlation experiments with radioactive ions. The trap geometry is also well suited to perform experiments with laser-cooled ions, serving for the development of a new type of Penning trap, in the framework of the project TRAPSENSOR at the University of Granada. The goal of this project is to use a single {sup 40}Ca{sup +} ion as detector for single-ion mass spectrometry. Within this project and without any modification to the initial electrode configuration, it was possible to perform Doppler cooling on {sup 40}Ca{sup +} ions, starting from large cloudsmore » and reaching single ion sensitivity. This new feature of the trap might be important also for other experiments with ions produced at radioactive ion beam facilities. In this publication, the trap and the laser system will be described, together with their performance with respect to laser cooling applied to large ion clouds down to a single ion.« less

  17. A serially coupled stationary phase method for the determination of urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine by liquid chromatography ion trap tandem mass spectrometry☆

    PubMed Central

    Rota, Cristina; Cristoni, Simone; Trenti, Tommaso; Cariani, Elisabetta

    2013-01-01

    Oxidative attack to DNA is of particular interest since DNA modifications can lead to heritable mutations. The most studied product of DNA oxidation is 8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxodG). While 8-oxodG determination in blood and tissue cells is prone to artifacts, its measurement in urine employing liquid chromatography tandem mass spectrometry (LC-MS/MS) has gained more and more interest for increased reliability. LC-MS/MS can be affected by matrix effects and this is particularly true when ion trap is used as MS analyzer, due to ion accumulation in the trap and related space charge effect. In the present work, we have developed a LC-MS/MS method where the combination of cation exchange and reverse phase solid phases resulted in LC separation optimization. This together with the employment of an isotopically labeled internal standard, allowed the usage of ion trap LC-MS/MS, typically not employed for quantitative measurement in biological samples, for the measurement of 8-oxodG in urine samples from control populations. Four different urine matrices were employed for method validation. Limit of quantitation was set at least at 0.5 ng/ml. While analyzing urine samples from healthy volunteers, 8-oxodG levels reported as ng/ml were statistically different comparing males with females (p<0.05, Mann Whitney test); while comparing results normalized for creatinine no statistical significant difference was found. Mean urinary 8-oxodG level found in healthy volunteers was 1.16±0.46 nmol/mmol creatinine. The present method by enhancing at best the chromatographic performances allows the usage of ion trap LC-MS/MS for the measurement of 8-oxodG in urine samples from control populations. PMID:24251117

  18. Attitudes of Danish pig farmers towards requirements for hospital pens.

    PubMed

    Thomsen, Peter T; Klottrup, Anne; Steinmetz, Henriette; Herskin, Mette S

    2016-06-01

    According to Danish legislation, sick or injured pigs must be housed in hospital pens with specific requirements. During recent years the majority of cases of non-compliance with legislation have been related to management of these animals. Hence, we hypothesized that 1) pig farmers generally find a requirement for hospital pens reasonable, but do not know the specific requirements; 2) pig farmers do not find the specific requirements for hospital pens meaningful compared with their perception of what sick pigs need; and 3) pig farmers often omit to move sick pigs to hospital pens due to lack of time or labour. An on-line questionnaire regarding farmers' attitudes towards and knowledge about legal requirements for hospital pens was constructed and e-mailed to 2348 pig farmers. In total, 508 farmers answered the questionnaire. Overall, 66% of the respondents found that the requirements for hospital pens made good sense, and more than 90% found that it made at least partial sense. Even though almost all respondents thought they knew the legal requirements for specific facilities in hospital pens, in fact 20% of them did not. The majority of respondents found all specific requirements in accordance with the needs of sick pigs, with the exception of cooling (only 17% agreed that cooling was needed). Unexpectedly, lack of time or labour wasn't reported to be a major obstacle to the use of hospital pens. Possibly, different thresholds for defining a pig as 'sick enough' to need housing in a hospital pen may exist between farmers and authorities. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Axisymmetric Tandem Mirrors: Stabilization and Confinement Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Post, R.F.; Fowler, T.K.; Bulmer, R.

    2005-01-15

    The 'Kinetic Stabilizer' has been proposed as a means of MHD stabilizing an axisymmetric tandem mirror system. The K-S concept is based on theoretical studies by Ryutov, confirmed experimentally in the Gas Dynamic Trap experiment in Novosibirsk. In the K-S beams of ions are directed into the end of an 'expander' region outside the outer mirror of a tandem mirror. These ions, slowed, stagnated, and reflected as they move up the magnetic gradient, produce a low-density stabilizing plasma.At the Lawrence Livermore National Laboratory we have been conducting theoretical and computational studies of the K-S Tandem Mirror. These studies have employedmore » a low-beta code written especially to analyze the beam injection/stabilization process,and a new code SYMTRAN (by Hua and Fowler)that solves the coupled radial and axial particle and energy transport in a K-S T-M. Also, a 'legacy' MHD stability code, FLORA, has been upgraded and employed to benchmark the injection/stabilization code and to extend its results to high beta values.The FLORA code studies so far have confirmed the effectiveness of the K-S in stabilizing high-beta (40%) plasmas with stabilizer plasmas the peak pressures of which are several orders of magnitude smaller than those of the confined plasma.Also the SYMTRAN code has shown D-T plasma ignition from alpha particle energy deposition in T-M regimes with strong end plugging.Our studies have confirmed the viability of the K-S T-M concept with respect to MHD stability and radial and axial confinement. We are continuing these studies in order to optimize the parameters and to examine means for the stabilization of possible residual instability modes, such as drift modes and 'trapped-particle' modes. These modes may in principle be controlled by tailoring the stabilizer plasma distribution and/or the radial potential distribution.In the paper the results to date of our studies are summarized and projected to scope out possible fusion-power versions of the

  20. Axisymmetric Tandem Mirrors: Stabilization and Confinement Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Post, R F; Fowler, T K; Bulmer, R

    2004-07-15

    The 'Kinetic Stabilizer' has been proposed as a means of MHD stabilizing an axisymmetric tandem mirror system. The K-S concept is based on theoretical studies by Ryutov, confirmed experimentally in the Gas Dynamic Trap experiment in Novosibirsk. In the K-S beams of ions are directed into the end of an 'expander' region outside the outer mirror of a tandem mirror. These ions, slowed, stagnated, and reflected as they move up the magnetic gradient, produce a low-density stabilizing plasma. At the Lawrence Livermore National Laboratory we have been conducting theoretical and computational studies of the K-S Tandem Mirror. These studies havemore » employed a low-beta code written especially to analyze the beam injection/stabilization process, and a new code SYMTRAN (by Hua and Fowler) that solves the coupled radial and axial particle and energy transport in a K-S TM. Also, a 'legacy' MHD stability code, FLORA, has been upgraded and employed to benchmark the injection/stabilization code and to extend its results to high beta values. The FLORA code studies so far have confirmed the effectiveness of the K-S in stabilizing high-beta (40%) plasmas with stabilizer plasmas the peak pressures of which are several orders of magnitude smaller than those of the confined plasma. Also the SYMTRAN code has shown D-T plasma ignition from alpha particle energy deposition in T-M regimes with strong end plugging. Our studies have confirmed the viability of the K-S-T-M concept with respect to MHD stability and radial and axial confinement. We are continuing these studies in order to optimize the parameters and to examine means for the stabilization of possible residual instability modes, such as drift modes and 'trapped-particle' modes. These modes may in principle be controlled by tailoring the stabilizer plasma distribution and/or the radial potential distribution. In the paper the results to date of our studies are summarized and projected to scope out possible fusion-power versions

  1. Miniature penetrator (MinPen) acceleration recorder development test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Franco, R.J.; Platzbecker, M.R.

    1998-08-01

    The Telemetry Technology Development Department at Sandia National Laboratories actively develops and tests acceleration recorders for penetrating weapons. This new acceleration recorder (MinPen) utilizes a microprocessor-based architecture for operational flexibility while maintaining electronics and packaging techniques developed over years of penetrator testing. MinPen has been demonstrated to function in shock environments up to 20,000 Gs. The MinPen instrumentation development has resulted in a rugged, versatile, miniature acceleration recorder and is a valuable tool for penetrator testing in a wide range of applications.

  2. Administration technique and storage of disposable insulin pens reported by patients with diabetes.

    PubMed

    Mitchell, Virginia D; Porter, Kyle; Beatty, Stuart J

    2012-01-01

    The purpose of the study was to evaluate insulin injection technique and storage of insulin pens as reported by patients with diabetes and to compare correct pen use to initial education on injection technique, hemoglobin A1C, duration of insulin therapy, and duration of insulin pen. Cross-sectional questionnaire orally administered to patients at a university-affiliated primary care practice. Subjects were patients with diabetes who were 18 years or older and prescribed a disposable insulin pen for at least 4 weeks. A correct usage score was calculated for each patient based on manufacturer recommendations for disposable insulin pen use. Associations were made between the correct usage score and certainty in technique, initial education, years of insulin therapy, duration of pen use, and hemoglobin A1C. Sixty-seven patients completed the questionnaire, reporting total use of 94 insulin pens. The 3 components most often neglected by patients were priming pen needle, holding for specific count time before withdrawal of pen needle from skin, and storing an in-use pen. For three-fourths of the insulin pens being used, users did not follow the manufacturer's instructions for proper administration and storage of insulin pens. Correct usage scores were significantly higher if initial education on insulin pens was performed by a pharmacist or nurse. The majority of patients may be ignoring or unaware of key components for consistent insulin dosing using disposable insulin pens; therefore, initial education and reeducation on correct use of disposable insulin pens by health care professionals are needed.

  3. Penning ionization widths by Fano-algebraic diagrammatic construction method

    NASA Astrophysics Data System (ADS)

    Yun, Renjie; Narevicius, Edvardas; Averbukh, Vitali

    2018-03-01

    We present an ab initio theory and computational method for Penning ionization widths. Our method is based on the Fano theory of resonances, algebraic diagrammatic construction (ADC) scheme for many-electron systems, and Stieltjes imaging procedure. It includes an extension of the Fano-ADC scheme [V. Averbukh and L. S. Cederbaum, J. Chem. Phys. 123, 204107 (2005)] to triplet excited states. Penning ionization widths of various He*-H2 states are calculated as a function of the distance R between He* and H2. We analyze the asymptotic (large-R) dependences of the Penning widths in the region where the well-established electron transfer mechanism of the decay is suppressed by the multipole- and/or spin-forbidden energy transfer. The R-12 and R-8 power laws are derived for the asymptotes of the Penning widths of the singlet and triplet excited states of He*(1s2s1,3S), respectively. We show that the electron transfer mechanism dominates Penning ionization of He*(1s2s 3S)-H2 up until the He*-H2 separation is large enough for the radiative decay of He* to become the dominant channel. The same mechanism also dominates the ionization of He*(1s2s 1S)-H2 when R < 5 Å. We estimate that the regime of energy transfer in the He*-H2 Penning ionization cannot be reached by approaching zero collisional temperature. However, the multipole-forbidden energy transfer mechanism can become important for Penning ionization in doped helium droplets.

  4. Battery-powered, electrocuting trap for stable flies (Diptera: Muscidae).

    PubMed

    Pickens, L G

    1991-11-01

    A solar-charged, battery-powered, electrocuting grid was combined with a white plywood base to make a portable, pulsed-current, pest-electrocuting device that attracted and killed stable flies, Stomoxys calcitrans (L.), outdoors. The grid was powered once every 1-2 s by a 0.016-s pulse of 60-Hz alternating current of 4 mA and 9,500 V. Power was turned off at night by a photoresistor. The trap functioned continuously for 14 d with an unrecharged 12-V, 18A/h lawn-tractor battery and killed as many as 4,000 flies per day. Solar cells were used to charge a single 12-V battery continuously that operated 12 grids for a period of 90 d. The grid did not short circuit for any length of time even during heavy rainstorms or when large insects were killed. The incorporation of moiré patterns and the utilization of the correct size, orientation, and placement of wires made the electrocuting grid itself attractive to stable flies. The traps were spaced at distances of up to 120 m from the battery and pulse circuit. The electrocuting traps were more effective than sticky traps and avoided the problems associated with chemicals. They are well suited for use around calf pens, dog kennels, or large animal shelters.

  5. Humalog(®) KwikPen™: an insulin-injecting pen designed for ease of use.

    PubMed

    Schwartz, Sherwyn L; Ignaut, Debra A; Bodie, Jennifer N

    2010-11-01

    Insulin pens offer significant benefits over vial and syringe injections for patients with diabetes who require insulin therapy. Insulin pens are more discreet, easier for patients to hold and inject, and provide better dosing accuracy than vial and syringe injections. The Humalog(®) KwikPen™ (prefilled insulin lispro [Humalog] pen, Eli Lilly and Company, Indianapolis, IN, USA) is a prefilled insulin pen highly rated by patients for ease of use in injections, and has been preferred by patients to both a comparable insulin pen and to vial and syringe injections in comparator studies. Together with an engineering study demonstrating smoother injections and reduced dosing error versus a comparator pen, recent evidence demonstrates the Humalog KwikPen device is an accurate, easy-to-use, patient-preferred insulin pen.

  6. A Comparison of Glide Force Characteristics Between 2 Prefilled Insulin Lispro Pens

    PubMed Central

    Lennartz, Amanda H.; Ignaut, Debra A.

    2015-01-01

    Background: Glide force, average glide force, and glide force variability of the insulin lispro 200 units/mL pen (Eli Lilly and Company, Indianapolis, IN, USA) were compared to the Humalog® KwikPen® 100 units/mL pen (hereafter, KwikPen; Eli Lilly and Company, Indianapolis, IN, USA). Methods: Data were collected on 2 doses, 2 injection speeds, and 2 needle types. Results: Insulin lispro 200 units/mL pen showed significantly lower maximum glide force, average glide force, and glide force variability than the KwikPen across all combinations of dose size, dose speed, and needle type. Conclusions: The lower glide force observed with the insulin lispro 200 units/mL pen offers another treatment option for patients with type 1 or type 2 diabetes who require greater than 20 units of mealtime insulin daily. PMID:25591858

  7. An Optical Trap for Relativistic Plasma

    NASA Astrophysics Data System (ADS)

    Zhang, Ping

    2002-11-01

    Optical traps have achieved remarkable success recently in confining ultra-cold matter.Traps capable of confining ultra-hot matter, or plasma, have also been built for applications such as basic plasma research and thermonuclear fusion. For instance, low-density plasmas with temperature less than 1 keV have been confined with static magnetic fields in Malmberg-Penning traps. Low-density 10-50 keV plasmas are confined in magnetic mirrors and tokamaks. High density plasmas have been trapped in optical traps with kinetic energies up to 10 keV [J. L. Chaloupka and D. D. Meyerhofer, Phys. Rev. Lett. 83, 4538 (1999)]. We present the results of experiment, theory and numerical simulation on an optical trap capable of confining relativistic plasma. A stationary interference grating with submicron spacing is created when two high-power (terawatt) laser pulses of equal wavelength (1-micron) are focused from orthogonal directions to the same point in space and time in high density underdense plasma. Light pressure gradients bunch electrons into sheets located at the minima of the interference pattern. The density of the bunched electrons is found to be up to ten times the background density, which is orders-of-magnitude above that previously reported for other optical traps or plasma waves. The amplitudes and frequencies of multiple satellites in the scattered spectrum also indicate the presence of a highly nonlinear ion wave and an electron temperature about 100 keV. Energy transfer from the stronger beam to the weaker beam is also observed. Potential applications include a test-bed for detailed studies of relativistic nonlinear scattering, a positron source and an electrostatic wiggler. This research is also relevant to fast igniter fusion or ion acceleration experiments, in which laser pulses with intensities comparable to those used in the experiment may also potentially beat [Y. Sentoku, et al., Appl. Phys. B 74, 207215 (2002)]. The details of a specific application, the

  8. Of Papers and Pens: Polysemes and Homophones in Lexical (Mis)Selection

    ERIC Educational Resources Information Center

    Li, Leon; Slevc, L. Robert

    2017-01-01

    Every word signifies multiple senses. Many studies using comprehension-based measures suggest that polysemes' senses (e.g., "paper" as in "printer paper" or "term paper") share lexical representations, whereas homophones' meanings (e.g., "pen" as in "ballpoint pen" or "pig pen")…

  9. The PEN&PAD data entry system: from prototype to practical system.

    PubMed Central

    Kirby, J.; Rector, A. L.

    1996-01-01

    This paper describes some of the issues addressed in the transition of the PEN&PAD from prototype clinical workstation to practical data entry system for use by general practitioners in the UK. Background and motivation of the PEN&PAD and GALEN projects are presented before the operation of the PEN&PAD user interface is described. A number of issues which have arisen in the development of the PEN&PAD Data Entry System are discussed. PMID:8947757

  10. 40 CFR 721.1750 - 1H-Benzotriazole, 5-(pen-tyl-oxy)- and 1H-ben-zo-tri-a-zole, 5-(pen-tyl-oxy)-, sodium and...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 1H-ben-zo-tri-a-zole, 5-(pen-tyl-oxy)-, sodium and potassium salts. 721.1750 Section 721.1750... 1H-Benzotriazole, 5-(pen-tyl-oxy)- and 1H-ben-zo-tri-a-zole, 5-(pen-tyl-oxy)-, sodium and potassium...-tyl-oxy)-, sodium salt (PMN P-92-35), and 1H-benzotriazole, 5-(pentyloxy)- , potassium salt (PMN P-92...

  11. 40 CFR 721.1750 - 1H-Benzotriazole, 5-(pen-tyl-oxy)- and 1H-ben-zo-tri-a-zole, 5-(pen-tyl-oxy)-, sodium and...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 1H-ben-zo-tri-a-zole, 5-(pen-tyl-oxy)-, sodium and potassium salts. 721.1750 Section 721.1750... 1H-Benzotriazole, 5-(pen-tyl-oxy)- and 1H-ben-zo-tri-a-zole, 5-(pen-tyl-oxy)-, sodium and potassium...-tyl-oxy)-, sodium salt (PMN P-92-35), and 1H-benzotriazole, 5-(pentyloxy)- , potassium salt (PMN P-92...

  12. 40 CFR 721.1750 - 1H-Benzotriazole, 5-(pen-tyl-oxy)- and 1H-ben-zo-tri-a-zole, 5-(pen-tyl-oxy)-, sodium and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 1H-ben-zo-tri-a-zole, 5-(pen-tyl-oxy)-, sodium and potassium salts. 721.1750 Section 721.1750... 1H-Benzotriazole, 5-(pen-tyl-oxy)- and 1H-ben-zo-tri-a-zole, 5-(pen-tyl-oxy)-, sodium and potassium...-tyl-oxy)-, sodium salt (PMN P-92-35), and 1H-benzotriazole, 5-(pentyloxy)- , potassium salt (PMN P-92...

  13. 40 CFR 721.1750 - 1H-Benzotriazole, 5-(pen-tyl-oxy)- and 1H-ben-zo-tri-a-zole, 5-(pen-tyl-oxy)-, sodium and...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 1H-ben-zo-tri-a-zole, 5-(pen-tyl-oxy)-, sodium and potassium salts. 721.1750 Section 721.1750... 1H-Benzotriazole, 5-(pen-tyl-oxy)- and 1H-ben-zo-tri-a-zole, 5-(pen-tyl-oxy)-, sodium and potassium...-tyl-oxy)-, sodium salt (PMN P-92-35), and 1H-benzotriazole, 5-(pentyloxy)- , potassium salt (PMN P-92...

  14. Flexible and fragmentable tandem photosensitive nanocrystal skins

    NASA Astrophysics Data System (ADS)

    Akhavan, S.; Uran, C.; Bozok, B.; Gungor, K.; Kelestemur, Y.; Lesnyak, V.; Gaponik, N.; Eychmüller, A.; Demir, H. V.

    2016-02-01

    We proposed and demonstrated the first account of large-area, semi-transparent, tandem photosensitive nanocrystal skins (PNSs) constructed on flexible substrates operating on the principle of photogenerated potential buildup, which avoid the need for applying an external bias and circumvent the current-matching limitation between junctions. We successfully fabricated and operated the tandem PNSs composed of single monolayers of colloidal water-soluble CdTe and CdHgTe nanocrystals (NCs) in adjacent junctions on a Kapton polymer tape. Owing to the usage of a single NC layer in each junction, noise generation was significantly reduced while keeping the resulting PNS films considerably transparent. In each junction, photogenerated excitons are dissociated at the interface of the semi-transparent Al electrode and the NC layer, with holes migrating to the contact electrode and electrons trapped in the NCs. As a result, the tandem PNSs lead to an open-circuit photovoltage buildup equal to the sum of those of the two single junctions, exhibiting a total voltage buildup of 128.4 mV at an excitation intensity of 75.8 μW cm-2 at 350 nm. Furthermore, we showed that these flexible PNSs could be bent over 3.5 mm radius of curvature and cut out in arbitrary shapes without damaging the operation of individual parts and without introducing any significant loss in the total sensitivity. These findings indicate that the NC skins are promising as building blocks to make low-cost, flexible, large-area UV/visible sensing platforms with highly efficient full-spectrum conversion.We proposed and demonstrated the first account of large-area, semi-transparent, tandem photosensitive nanocrystal skins (PNSs) constructed on flexible substrates operating on the principle of photogenerated potential buildup, which avoid the need for applying an external bias and circumvent the current-matching limitation between junctions. We successfully fabricated and operated the tandem PNSs composed of

  15. 47 CFR 69.111 - Tandem-switched transport and tandem charge.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 3 2011-10-01 2011-10-01 false Tandem-switched transport and tandem charge. 69... SERVICES (CONTINUED) ACCESS CHARGES Computation of Charges § 69.111 Tandem-switched transport and tandem...-switched transport shall consist of two rate elements, a transmission charge and a tandem switching charge...

  16. Ease of use and patient preference injection simulation study comparing two prefilled insulin pens.

    PubMed

    Clark, Paula E; Valentine, Virginia; Bodie, Jennifer N; Sarwat, Samiha

    2010-07-01

    To determine patient ease of use and preference for the Humalog KwikPen* (prefilled insulin lispro [Humalog dagger] pen, Eli Lilly and Company, Indianapolis, IN, USA) (insulin lispro pen) versus the Next Generation FlexPen double dagger (prefilled insulin aspart [NovoRapid section sign ] pen, Novo Nordisk A/S, Bagsvaerd, Denmark) (insulin aspart pen). This was a randomized, open-label, 2-period, 8-sequence crossover study in insulin pen-naïve patients with diabetes. Randomized patients (N = 367) received device training, then simulated low- (15 U) and high- (60 U) dose insulin injections with an appliance. Patients rated pens using an ease of use questionnaire and were asked separately for final pen preferences. The Insulin Device 'Ease of Use' Battery is a 10-item questionnaire with a 7-point scale (higher scores reflect greater ease of use). The primary objective was to determine pen preference for 'easy to press to inject my dose' (by comparing composite scores [low- plus high-dose]). Secondary objectives were to determine pen preference on select questionnaire items (from composite scores), final pen preference, and summary responses for all questionnaire items. On the primary endpoint, 'easy to press to inject my dose,' a statistically significant majority of patients with a preference chose the insulin lispro pen over the insulin aspart pen (68.4%, 95% CI = 62.7-73.6%). Statistically significant majorities of patients with a preference also favored the insulin lispro pen on secondary items: 'easy to hold in my hand when I inject' (64.9%, 95% CI = 58.8-70.7%), 'easy to use when I am in a public place' (67.5%, 95% CI = 61.0-73.6%), and 'overall easy to use' (69.9%, 95% CI = 63.9-75.4%). A statistically significant majority of patients had a final preference for the insulin lispro pen (67.3%, 95% CI = 62.2-72.1%). Among pen-naïve patients with diabetes who had a preference, the majority preferred the insulin lispro pen over the insulin aspart pen with regard

  17. Trapped Ion Oscillation Frequencies as Sensors for Spectroscopy

    PubMed Central

    Vogel, Manuel; Quint, Wolfgang; Nörtershäuser, Wilfried

    2010-01-01

    The oscillation frequencies of charged particles in a Penning trap can serve as sensors for spectroscopy when additional field components are introduced to the magnetic and electric fields used for confinement. The presence of so-called “magnetic bottles” and specific electric anharmonicities creates calculable energy-dependences of the oscillation frequencies in the radiofrequency domain which may be used to detect the absorption or emission of photons both in the microwave and optical frequency domains. The precise electronic measurement of these oscillation frequencies therefore represents an optical sensor for spectroscopy. We discuss possible applications for precision laser and microwave spectroscopy and their role in the determination of magnetic moments and excited state life-times. Also, the trap-assisted measurement of radiative nuclear de-excitations in the X-ray domain is discussed. This way, the different applications range over more than 12 orders of magnitude in the detectable photon energies, from below μeV in the microwave domain to beyond MeV in the X-ray domain. PMID:22294921

  18. Review: Factors affecting fouling in conventional pens for slaughter pigs.

    PubMed

    Larsen, M L V; Bertelsen, M; Pedersen, L J

    2018-02-01

    This review assesses factors affecting fouling in conventional pens for slaughter pigs. Fouling of the pen happens when pigs change their excretory behaviour from occurring in the designated dunging area to the lying area. This can result in a lower hygiene, bad air quality, extra work for the farmer, disturbance of the pigs' resting behaviour and an increase in agonistic interactions. A systematic search was conducted and results narrowed down to 21 articles. Four factors were found to affect fouling directly: insufficient space allowance, the flooring design of the pen, the thermal climate and pigs' earlier experience. Further, these primary factors are affected by secondary factors such as the shape of the pen, the weight of the pigs and especially the heat balance of the pigs, which is affected by several tertiary factors including, for example, temperature, humidity and draught. Results indicate that the most important factor to control when trying to prevent fouling of a pen is the pen climate. An appropriate climate may be accomplished through floor cooling in the designated lying area, sprinklers above the designated dunging area and by ensuring a more optimal ambient temperature curve that also fits the weight of the pigs in different stages of the production. All in all, fouling of the pen in conventional slaughter pigs is a multifactorial problem, but it is important to focus on increasing the comfortability, and especially the climate, of the designated lying area.

  19. Comparative Assessment of Lixisenatide, Exenatide, and Liraglutide Pen Devices: A Pilot User-Based Study.

    PubMed

    Stauder, Udo; Enginee, Diplom; Elton, Hina; Penfornis, Alfred; Edelman, Steve

    2014-01-01

    Glucagon-like peptide-1 (GLP-1) receptor agonists are a relatively recent addition to the treatment options for type 2 diabetes mellitus (T2DM) and are administered using prefilled pen devices. In this open-label task and interview-based pilot study, 3 GLP-1 receptor agonist pen devices-exenatide (Byetta ® , Bristol-Myers Squibb/AstraZeneca), liraglutide (Victoza ® , Novo Nordisk), and lixisenatide (Lyxumia ® , Sanofi-Aventis)-were comparatively assessed in a randomized order in 30 participants with T2DM for ease of use, using a series of key performance measures (time taken to complete a series of tasks, number of user errors [successful performance], and user satisfaction rating). Linear and logistic regression analysis was conducted for the lixisenatide and liraglutide pens versus the exenatide pen. Participants' mean age was 60 years; 27% and 20% of the participants had visual impairments and reduced manual dexterity, respectively. Tasks were completed faster (P < .001) and with higher successful performance (P = .001) with the lixisenatide pen than with the exenatide pen, whereas the liraglutide pen was not statistically significant versus the exenatide pen on these parameters. Overall, user satisfaction was statistically higher for the lixisenatide and liraglutide pens versus the exenatide pen (P < .001 for both). Lixisenatide and liraglutide pens are associated with higher user satisfaction compared with the exenatide pen. In addition, the lixisenatide pen is faster and results in fewer errors than its comparator (exenatide). The lixisenatide pen may therefore be a suitable choice for patients with T2DM, including older and pen device-naïve patients, and those with visual impairments and reduced manual dexterity. © 2014 Diabetes Technology Society.

  20. Psychometric Assessment of the Injection Pen Assessment Questionnaire (IPAQ): measuring ease of use and preference with injection pens for human growth hormone

    PubMed Central

    2012-01-01

    Purpose To examine the psychometric properties of the Injection Pen Assessment Questionnaire (IPAQ) including the following: 1) item and scale characteristics (e.g., frequencies, item distributions, and factor structure), 2) reliability, and 3) validity. Methods Focus groups and one-on-one dyad interviews guided the development of the IPAQ. The IPAQ was subsequently tested in 136 parent–child dyads in a Phase 3, 2-month, open-label, multicenter trial for a new Genotropin® disposable pen. Factor analysis was performed to inform the development of a scoring algorithm, and reliability and validity of the IPAQ were evaluated using the data from this two months study. Psychometric analyses were conducted separately for each injection pen. Results Confirmatory factor analysis provides evidence supporting a second order factor solution for four subscales and a total IPAQ score. These factor analysis results support the conceptual framework developed from previous qualitative research in patient dyads using the reusable pen. However, the IPAQ subscales did not consistently meet acceptable internal consistency reliability for some group level comparisons. Cronbach’s alphas for the total IPAQ score for both pens were 0.85, exceeding acceptable levels of reliability for group comparisons. Conclusions The total IPAQ score is a useful measure for evaluating ease of use and preference for injection pens in clinical trials among patient dyads receiving hGH. The psychometric properties of the individual subscales, mainly the lower internal consistency reliability of some of the subscales and the predictive validity findings, do not support the use of subscale scores alone as a primary endpoint. PMID:23046797

  1. Ultrafast state detection and 2D ion crystals in a Paul trap

    NASA Astrophysics Data System (ADS)

    Ip, Michael; Ransford, Anthony; Campbell, Wesley

    2016-05-01

    Projective readout of quantum information stored in atomic qubits typically uses state-dependent CW laser-induced fluorescence. This method requires an often sophisticated imaging system to spatially filter out the background CW laser light. We present an alternative approach that instead uses simple pulse sequences from a mode-locked laser to affect the same state-dependent excitations in less than 1 ns. The resulting atomic fluorescence occurs in the dark, allowing the placement of non-imaging detectors right next to the atom to improve the qubit state detection efficiency and speed. We also study 2D Coulomb crystals of atomic ions in an oblate Paul trap. We find that crystals with hundreds of ions can be held in the trap, potentially offering an alternative to the use of Penning traps for the quantum simulation of 2D lattice spin models. We discuss the classical physics of these crystals and the metastable states that are supported in 2D. This work is supported by the US Army Research Office.

  2. Pen-based Interfaces for Engineering and Education

    NASA Astrophysics Data System (ADS)

    Stahovich, Thomas F.

    Sketches are an important problem-solving tool in many fields. This is particularly true of engineering design, where sketches facilitate creativity by providing an efficient medium for expressing ideas. However, despite the importance of sketches in engineering practice, current engineering software still relies on traditional mouse and keyboard interfaces, with little or no capabilities to handle free-form sketch input. With recent advances in machine-interpretation techniques, it is now becoming possible to create practical interpretation-based interfaces for such software. In this chapter, we report on our efforts to create interpretation techniques to enable pen-based engineering applications. We describe work on two fundamental sketch understanding problems. The first is sketch parsing, the task of clustering pen strokes or geometric primitives into individual symbols. The second is symbol recognition, the task of classifying symbols once they have been located by a parser. We have used the techniques that we have developed to construct several pen-based engineering analysis tools. These are used here as examples to illustrate our methods. We have also begun to use our techniques to create pen-based tutoring systems that scaffold students in solving problems in the same way they would ordinarily solve them with paper and pencil. The chapter concludes with a brief discussion of these systems.

  3. Dose Accuracy and Injection Force of Different Insulin Glargine Pens

    PubMed Central

    Friedrichs, Arnd; Bohnet, Janine; Korger, Volker; Adler, Steffen; Schubert-Zsilavecz, Manfred; Abdel-Tawab, Mona

    2013-01-01

    Background Dose accuracy and injection force, representing key parameters of insulin pens, were determined for three pens delivering insulin glargine-based copies, Pen Royale (WR) and DispoPen (WD) for Glaritus® (Wockhardt) and GanLee Pen (GL) for Basalin® (Gan & Lee), compared with pens of the originator, ClikSTAR® (CS) and S o l o S TA R® (SS) for Lantus® (Sanofi) . Methods Using the weighing procedure recommended by DIN EN ISO 11608–1:2000, dose accuracy was evaluated based on nonrandomized delivery of low (5 U), mid (30 U), and high (60 U) dosage levels. Injection force was measured by dispensing the maximum dose of insulin (60 U for the GL, WR, and WD; 80 U for the SS and CS) at dose speeds of 6 and 10 U/s. Results All tested pens delivered comparable average doses within the DIN EN ISO 11608–1:2000 limits at all dosage levels. The GL revealed a higher coefficient of variation (CV) at 5 U, and the WR and WD had higher CVs at all dosage levels compared with the CS and SS. Injection force was higher for the WR, WD, and GL compared with the CS and SS at both dose speeds. In contrast to the CS and SS with an end-of-content feature, doses exceeding the remaining insulin could be dialed with the WR, GL, and WD and, apparently, dispensed with the WD. Conclusions All pens fulfilled the dose accuracy requirements defined by DIN EN ISO 11608–1:2000 standards at all three dosage levels, with the WR, WD, and GL showing higher dosage variability and injection force compared with the SS and CS. Thus, the devices that deliver insulin glargine copies show different performance characteristics compared with the originator. J Diabetes Sci Technol 2013;7(5):1346–1353 PMID:24124963

  4. MATS and LaSpec: High-precision experiments using ion traps and lasers at FAIR

    NASA Astrophysics Data System (ADS)

    Rodríguez, D.; Blaum, K.; Nörtershäuser, W.; Ahammed, M.; Algora, A.; Audi, G.; Äystö, J.; Beck, D.; Bender, M.; Billowes, J.; Block, M.; Böhm, C.; Bollen, G.; Brodeur, M.; Brunner, T.; Bushaw, B. A.; Cakirli, R. B.; Campbell, P.; Cano-Ott, D.; Cortés, G.; Crespo López-Urrutia, J. R.; Das, P.; Dax, A.; de, A.; Delheij, P.; Dickel, T.; Dilling, J.; Eberhardt, K.; Eliseev, S.; Ettenauer, S.; Flanagan, K. T.; Ferrer, R.; García-Ramos, J.-E.; Gartzke, E.; Geissel, H.; George, S.; Geppert, C.; Gómez-Hornillos, M. B.; Gusev, Y.; Habs, D.; Heenen, P.-H.; Heinz, S.; Herfurth, F.; Herlert, A.; Hobein, M.; Huber, G.; Huyse, M.; Jesch, C.; Jokinen, A.; Kester, O.; Ketelaer, J.; Kolhinen, V.; Koudriavtsev, I.; Kowalska, M.; Krämer, J.; Kreim, S.; Krieger, A.; Kühl, T.; Lallena, A. M.; Lapierre, A.; Le Blanc, F.; Litvinov, Y. A.; Lunney, D.; Martínez, T.; Marx, G.; Matos, M.; Minaya-Ramirez, E.; Moore, I.; Nagy, S.; Naimi, S.; Neidherr, D.; Nesterenko, D.; Neyens, G.; Novikov, Y. N.; Petrick, M.; Plaß, W. R.; Popov, A.; Quint, W.; Ray, A.; Reinhard, P.-G.; Repp, J.; Roux, C.; Rubio, B.; Sánchez, R.; Schabinger, B.; Scheidenberger, C.; Schneider, D.; Schuch, R.; Schwarz, S.; Schweikhard, L.; Seliverstov, M.; Solders, A.; Suhonen, M.; Szerypo, J.; Taín, J. L.; Thirolf, P. G.; Ullrich, J.; van Duppen, P.; Vasiliev, A.; Vorobjev, G.; Weber, C.; Wendt, K.; Winkler, M.; Yordanov, D.; Ziegler, F.

    2010-05-01

    Nuclear ground state properties including mass, charge radii, spins and moments can be determined by applying atomic physics techniques such as Penning-trap based mass spectrometry and laser spectroscopy. The MATS and LaSpec setups at the low-energy beamline at FAIR will allow us to extend the knowledge of these properties further into the region far from stability. The mass and its inherent connection with the nuclear binding energy is a fundamental property of a nuclide, a unique “fingerprint”. Thus, precise mass values are important for a variety of applications, ranging from nuclear-structure studies like the investigation of shell closures and the onset of deformation, tests of nuclear mass models and mass formulas, to tests of the weak interaction and of the Standard Model. The required relative accuracy ranges from 10-5 to below 10-8 for radionuclides, which most often have half-lives well below 1 s. Substantial progress in Penning trap mass spectrometry has made this method a prime choice for precision measurements on rare isotopes. The technique has the potential to provide high accuracy and sensitivity even for very short-lived nuclides. Furthermore, ion traps can be used for precision decay studies and offer advantages over existing methods. With MATS (Precision Measurements of very short-lived nuclei using an A_dvanced Trapping System for highly-charged ions) at FAIR we aim to apply several techniques to very short-lived radionuclides: High-accuracy mass measurements, in-trap conversion electron and alpha spectroscopy, and trap-assisted spectroscopy. The experimental setup of MATS is a unique combination of an electron beam ion trap for charge breeding, ion traps for beam preparation, and a high-precision Penning trap system for mass measurements and decay studies. For the mass measurements, MATS offers both a high accuracy and a high sensitivity. A relative mass uncertainty of 10-9 can be reached by employing highly-charged ions and a non

  5. C70/C70:pentacene/pentacene organic heterojunction as the connecting layer for high performance tandem organic light-emitting diodes: Mechanism investigation of electron injection and transport

    NASA Astrophysics Data System (ADS)

    Guo, Qingxun; Yang, Dezhi; Chen, Jiangshan; Qiao, Xianfeng; Ahamad, Tansir; Alshehri, Saad M.; Ma, Dongge

    2017-03-01

    A high performance tandem organic light-emitting diode (OLED) is realized by employing a C70/C70:pentacene/pentacene organic heterojunction as the efficient charge generation layer (CGL). Not only more than two time enhancement of external quantum efficiency but also significant improvement in both power efficiency and lifetime are well achieved. The mechanism investigations find that the electron injection from the CGL to the adjacent electron transport layer (ETL) in tandem devices is injection rate-limited due to the high interface energy barrier between the CGL and the ETL. By the capacitance-frequency (C-F) and low temperature current density-voltage (J-V) characteristic analysis, we confirm that the electron transport is a space-charge-limited current process with exponential trap distribution. These traps are localized states below the lowest unoccupied molecular orbital edge inside the gap and would be filled with the upward shift of the Fermi level during the n-doping process. Furthermore, both the trap density (Ht) and the activation energy (Ea) could be carefully worked out through low temperature J-V measurements, which is very important for developing high performance tandem OLEDs.

  6. Stereodivergent Synthesis of N-Heterocycles by Catalyst-Controlled, Activity-Directed Tandem Annulation of Diazo Compounds with Amino Alkynes.

    PubMed

    Liu, Kai; Zhu, Chenghao; Min, Junxiang; Peng, Shiyong; Xu, Guangyang; Sun, Jiangtao

    2015-10-26

    A stereodivergent synthesis of five-membered N-heterocycles, such as 2,3-dihydropyrroles, and 2-methylene and 3-methylene pyrrolidines, has been developed through a tandem annulation of amino alkynes with diazo compounds and involves the trapping of in situ formed intermediates. Mechanistic investigations indicate that the copper-catalyzed tandem annulations proceed by allenoate formation and subsequent intramolecular hydroamination. In contrast, the rhodium-catalyzed protocol features a carbenoid insertion into the NH bond and subsequent Conia-ene cyclization. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Of Papers and Pens: Polysemes and Homophones in Lexical (mis)Selection.

    PubMed

    Li, Leon; Slevc, L Robert

    2017-05-01

    Every word signifies multiple senses. Many studies using comprehension-based measures suggest that polysemes' senses (e.g., paper as in printer paper or term paper) share lexical representations, whereas homophones' meanings (e.g., pen as in ballpoint pen or pig pen) correspond to distinct lexical representations. Less is known about the lexical representations of polysemes compared to homophones in language production. In this study, speakers named pictures after reading sentence fragments that primed polysemes and homophones either as direct competitors to pictures (i.e., semantic-competitors), or as indirect-competitors to pictures (e.g., polysemous senses of semantic competitors, or homophonous meanings of semantic competitors). Polysemes (e.g., paper) elicited equal numbers of intrusions to picture names (e.g., cardboard) compared to in control conditions whether primed as direct competitors (printer paper) or as indirect-competitors (term paper). This contrasted with the finding that homophones (e.g., pen) elicited more intrusions to picture names (e.g., crayon) compared to in control conditions when primed as direct competitors (ballpoint pen) than when primed as indirect-competitors (pig pen). These results suggest that polysemes, unlike homophones, are stored and retrieved as unified lexical representations. Copyright © 2016 Cognitive Science Society, Inc.

  8. Maximum Likelihood Analysis in the PEN Experiment

    NASA Astrophysics Data System (ADS)

    Lehman, Martin

    2013-10-01

    The experimental determination of the π+ -->e+ ν (γ) decay branching ratio currently provides the most accurate test of lepton universality. The PEN experiment at PSI, Switzerland, aims to improve the present world average experimental precision of 3 . 3 ×10-3 to 5 ×10-4 using a stopped beam approach. During runs in 2008-10, PEN has acquired over 2 ×107 πe 2 events. The experiment includes active beam detectors (degrader, mini TPC, target), central MWPC tracking with plastic scintillator hodoscopes, and a spherical pure CsI electromagnetic shower calorimeter. The final branching ratio will be calculated using a maximum likelihood analysis. This analysis assigns each event a probability for 5 processes (π+ -->e+ ν , π+ -->μ+ ν , decay-in-flight, pile-up, and hadronic events) using Monte Carlo verified probability distribution functions of our observables (energies, times, etc). A progress report on the PEN maximum likelihood analysis will be presented. Work supported by NSF grant PHY-0970013.

  9. Dose accuracy and injection force dynamics of a novel disposable insulin pen.

    PubMed

    Clarke, Alastair; Spollett, Geralyn

    2007-03-01

    SoloStar (sanofi-aventis) is a new, disposable insulin pen for the administration of insulin glargine (Lantus, sanofi-aventis) or insulin glulisine (Apidra, sanofi-aventis). SoloStar was developed to address a wide range of patient needs and demonstrates advancement over previous devices, owing to its appropriate combination of ergonomically-tested and mechanically improved features. The authors report the results of key investigations carried out by sanofi-aventis as part of the SoloStar development plan, including dose accuracy and injection force testing. Comparisons between SoloStar and two commonly used pens, FlexPen (Novo Nordisk) and the Humulin/Humalog pen (Eli Lilly) establish SoloStar as a state of the art pen that is suitable for most patients with diabetes.

  10. Engineered spin-spin interactions on a 2D array of trapped ions

    NASA Astrophysics Data System (ADS)

    Britton, Joe; Sawyer, Brian; Bollinger, John

    2013-05-01

    We work with laser cooled 9Be+ ions confined in a Penning trap to simulate quantum magnetic interactions. The valence electron of each ion behaves as an ideal spin- 1 / 2 particle. We recently demonstrated a uniform anti-ferromagnetic Ising interaction on a naturally occurring two-dimensional (2D) triangular crystal of 100 < N < 350 ions. The Ising interaction is generated by a spin-dependent optical dipole force (ODF). For spins separated by distance d, we show that the range can be tuned according to (d / d 0)-a, for 0 < a < 3 . For different operating parameters we can also generate an infinite range ferromagnetic Ising interaction. We also use the ODF for spectroscopy and thermometry of the normal modes of the trapped ion array. A detailed understanding of the modes is important because they mediate the spin-spin interactions. This work is supported by NIST and the DARPA OLE program.

  11. [Determination of 14 heterocyclic aromatic amines in wine by liquid chromatography-ion trap-time of flight tandem mass spectrometry].

    PubMed

    Wang, Min; Guo, Dehua; Ding, Zhuoping; Yao, Jinting; Li, Fengge; Su, Min

    2012-07-01

    A rapid qualitative and quantitative analytical method was developed for the simultaneous determination of 14 heterocyclic aromatic amines (HAAs) in wine by liquid chromatography-ion trap-time of flight tandem mass spectrometry (LC-IT-TOF MS). HAAs were extracted from the samples by ethyl acetate under alkaline condition. The quantitation was carried out using internal standard method. The separation of HAAs was carried out based on Phenomenex Kinetex C18 100A column (100 mm x 2.1 mm, 2.6 microm), with a gradient elution of acetonitrile and 30 mmol/L ammonium formate at a flow rate of 0.4 mL/min. The analytes were detected under positive-ion electrospray ionization mode. The results showed that the linear ranges of the 14 HAAs were 1-500 microg/L with limits of detection (signal/noise = 3) of 0.33-1.77 microg/L. The average recoveries of all the compounds spiked in wine samples at three levels of 10, 50, 100 microg/L were in the ranges of 71.6%-96.4%, 72.9%-101.9%, 74.5%-103.3%, with the corresponding relative standard deviations (RSDs, n = 6) of 2.9%-7.9%, 1.7%-5.3%, 1.8%-4.8%, respectively. The established method is simple, rapid, accurate, and has wide linear range and high sensitivity. It can be applied to the simultaneous analysis of the HAAs in wine.

  12. 9 CFR 313.1 - Livestock pens, driveways and ramps.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) Livestock pens, driveways and ramps shall be maintained in good repair. They shall be free from sharp or... acceptable construction and maintenance. (c) U.S. Suspects (as defined in § 301.2(xxx)) and dying, diseased... awaiting disposition by the inspector. (d) Livestock pens and driveways shall be so arranged that sharp...

  13. Towards Simulating the Transverse Ising Model in a 2D Array of Trapped Ions

    NASA Astrophysics Data System (ADS)

    Sawyer, Brian

    2013-05-01

    Two-dimensional Coulomb crystals provide a useful platform for large-scale quantum simulation. Penning traps enable confinement of large numbers of ions (>100) and allow for the tunable-range spin-spin interactions demonstrated in linear ion strings, facilitating simulation of quantum magnetism at a scale that is currently intractable on classical computers. We readily confine hundreds of Doppler laser-cooled 9Be+ within a Penning trap, producing a planar array of ions with self-assembled triangular order. The transverse ``drumhead'' modes of our 2D crystal along with the valence electron spin of Be+ serve as a resource for generating spin-motion and spin-spin entanglement. Applying a spin-dependent optical dipole force (ODF) to the ion array, we perform spectroscopy and thermometry of individual drumhead modes. This ODF also allows us to engineer long-range Ising spin couplings of either ferromagnetic or anti-ferromagnetic character whose approximate power-law scaling with inter-ion distance, d, may be varied continuously from 1 /d0 to 1 /d3. An effective transverse magnetic field is applied via microwave radiation at the ~124-GHz spin-flip frequency, and ground states of the effective Ising Hamiltonian may in principle be prepared adiabatically by slowly decreasing this transverse field in the presence of the induced Ising coupling. Long-range anti-ferromagnetic interactions are of particular interest due to their inherent spin frustration and resulting large, near-degenerate manifold of ground states. We acknowledge support from NIST and the DARPA-OLE program.

  14. Facilitating the safe use of insulin pens in hospitals through a mentored quality-improvement program.

    PubMed

    Lutz, Mark F; Haines, Stuart T; Lesch, Christine A; Szumita, Paul M

    2016-10-01

    Results of the MENTORED QUALITY IMPROVEMENT IMPACT PROGRAM℠ (MQIIP) on Ensuring Insulin Pen Safety in Hospitals, which was part of an ASHP educational initiative aimed at ensuring the safe use of insulin pens in hospitals, are described. During this ASHP initiative, which also included continuing-education activities and Web-based resources, distance mentoring by pharmacists with expertise in the safe use of insulin pens was provided to interprofessional teams at 14 hospitals between September 2014 and May 2015. The results of baseline assessments of nursing staff knowledge of insulin pen use, insulin pen storage and labeling audits, and insulin pen injection observations conducted in September and October 2014 were the basis for insulin pen quality-improvement plans. Postintervention data were collected in April and May 2015. Compared with the baseline period, significant improvements in nurses' knowledge of insulin pen use, insulin pen labeling and storage, and insulin pen administration were observed in the postintervention period despite the relatively short time frame for implementation of quality-improvement plans. Program participants are committed to sustaining and building on improvements achieved during the program. The outcome measures described in this report could be adapted by other health systems to identify opportunities to improve the safety of insulin pen use. Focused attention on insulin pen safety through an interprofessional team approach during the MQIIP enabled participating sites to detect potential safety issues based on collected data, develop targeted process changes, document improvements, and identify areas requiring further intervention. A sustained organizational commitment is required to ensure the safe use of insulin pen devices in hospitals. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  15. Engineering study comparing injection force and dose accuracy between two prefilled insulin injection pens.

    PubMed

    Ignaut, Debra A; Opincar, Michael R; Clark, Paula E; Palaisa, Melanie K; Lenox, Sheila M

    2009-12-01

    This study compared injection force (measured by glide force [GF] and glide force variability [GFV]) and dosing accuracy of the Humalog KwikPen * (prefilled insulin lispro [Humalog dagger] pen, Eli Lilly and Company, Indianapolis, IN) and the Next Generation FlexPen double dagger (prefilled insulin aspart [NovoRapid section sign] pen, Novo Nordisk A/S, Bagsvaerd, Denmark). * Humalog KwikPen is a registered trademark of Eli Lilly and Company, Indianapolis, IN, USA. dagger Humalog is a registered trademark of Eli Lilly and Company, Indianapolis, IN, USA. double dagger FlexPen is a registered trademark of Novo Nordisk A/S, Bagsvaerd, Denmark. section sign NovoRapid is a registered trademark of Novo Nordisk A/S, Bagsvaerd, Denmark. A total of 100 prefilled insulin pens (50 insulin lispro pens, 50 insulin aspart pens) were tested using two dose sizes (30 U and 60 U). In all, 50 devices (25 of each type) were tested at 10 U/s dosing speed and 50 were tested at 6.6 U/s. Devices were used per manufacturer instructions. Dose accuracy (represented as absolute dose error %), maximum and average GF, and GFV data were automatically collected by the test system for all datasets (dose size/dosing speed/device type). The test system controlled for potential dosing errors. The insulin lispro pen demonstrated a significantly lower median maximum GF at both dosing speeds: (2.83 vs. 3.92 lbs [30 U] and 3.00 vs. 4.14 lbs [60 U]) at 10 U/s; (1.85 vs. 2.93 lbs [30 U] and 2.14 vs. 3.02 lbs [60 U]) at 6.6 U/s, all p < 0.0001. For all datasets, the median GFV was significantly lower for the insulin lispro pen, p < 0.0001. Median dose error was comparable between device types when tested at 10 U/s dosing speed; however, at 6.6 U/s, the median dose error was significantly lower for insulin lispro pen compared to insulin aspart pen (0.47 vs. 0.67% [30 U] and 0.50 vs. 0.78% [60 U], both p < 0.05). The insulin lispro pen had significantly lower median GF and GFV compared with insulin aspart pen

  16. Clinical application of a light-pen computer system for quantitative angiography

    NASA Technical Reports Server (NTRS)

    Alderman, E. L.

    1975-01-01

    The important features in a clinical system for quantitative angiography were examined. The human interface for data input, whether an electrostatic pen, sonic pen, or light-pen must be engineered to optimize the quality of margin definition. The computer programs which the technician uses for data entry and computation of ventriculographic measurements must be convenient to use on a routine basis in a laboratory performing multiple studies per day. The method used for magnification correction must be continuously monitored.

  17. Phosphorylation is required for the pathogen defense function of the Arabidopsis PEN3 ABC transporter.

    PubMed

    Underwood, William; Somerville, Shauna C

    2017-10-03

    The Arabidopsis PEN3 ABC transporter accumulates at sites of pathogen detection, where it is involved in defense against a number of pathogens. Perception of PAMPs by pattern recognition receptors initiates recruitment of PEN3 and also leads to PEN3 phosphorylation at multiple amino acid residues. Whether PAMP-induced phosphorylation of PEN3 is important for its defense function or focal recruitment has not been addressed. In this study, we evaluated the role of PEN3 phosphorylation in modulating the localization and defense function of the transporter. We report that PEN3 phosphorylation is critical for its function in defense, but dispensable for recruitment to powdery mildew penetration sites. These results indicate that PAMP-induced phosphorylation is likely to regulate the transport activity of PEN3.

  18. MR-Tandem: parallel X!Tandem using Hadoop MapReduce on Amazon Web Services.

    PubMed

    Pratt, Brian; Howbert, J Jeffry; Tasman, Natalie I; Nilsson, Erik J

    2012-01-01

    MR-Tandem adapts the popular X!Tandem peptide search engine to work with Hadoop MapReduce for reliable parallel execution of large searches. MR-Tandem runs on any Hadoop cluster but offers special support for Amazon Web Services for creating inexpensive on-demand Hadoop clusters, enabling search volumes that might not otherwise be feasible with the compute resources a researcher has at hand. MR-Tandem is designed to drop in wherever X!Tandem is already in use and requires no modification to existing X!Tandem parameter files, and only minimal modification to X!Tandem-based workflows. MR-Tandem is implemented as a lightly modified X!Tandem C++ executable and a Python script that drives Hadoop clusters including Amazon Web Services (AWS) Elastic Map Reduce (EMR), using the modified X!Tandem program as a Hadoop Streaming mapper and reducer. The modified X!Tandem C++ source code is Artistic licensed, supports pluggable scoring, and is available as part of the Sashimi project at http://sashimi.svn.sourceforge.net/viewvc/sashimi/trunk/trans_proteomic_pipeline/extern/xtandem/. The MR-Tandem Python script is Apache licensed and available as part of the Insilicos Cloud Army project at http://ica.svn.sourceforge.net/viewvc/ica/trunk/mr-tandem/. Full documentation and a windows installer that configures MR-Tandem, Python and all necessary packages are available at this same URL. brian.pratt@insilicos.com

  19. Ion Dynamic Capture Experiments With The High Performance Antiproton Trap (HiPAT)

    NASA Technical Reports Server (NTRS)

    Martin, James; Lewis, Raymond; Chakrabarti, Suman; Sims, William H.; Pearson, J. Boise; Fant, Wallace E.

    2002-01-01

    To take the first step towards using the energy produced from the matter-antimatter annihilation for propulsion applications, the NASA Marshall Space Flight Center (MSFC) Propulsion Research Center (PRC) has initiated a research activity examining the storage of low energy antiprotons. The High Performance Antiproton Trap (HiPAT) is an electromagnetic system (Penning-Malmberg design) consisting of a 4 Tesla superconductor, a high voltage electrode confinement system, and an ultra high vacuum test section. It has been designed with an ultimate goal of maintaining 10(exp 12) charged particles with a half-life of 18 days. Currently, this system is being evaluated experimentally using normal matter ions that are cheap to produce, relatively easy to handle, and provide a good indication of overall trap behavior (with the exception of assessing annihilation losses). The ions are produced via a positive hydrogen ion source and transported to HiPAT in a beam line equipped with electrostatic optics. The optics serve to both focus and gate the incoming ions, providing microsecond-timed beam pulses that are dynamically captured by cycling the HiPAT forward containment field like a "trap door". Initial dynamic capture experiments have been successfully performed with beam energy and currents set to 1.9 kV and 23 micro-amps, respectively. At these settings up to 2x10(exp 9) ions have been trapped during a single dynamic cycle.

  20. Dynamic-compliance and viscosity of PET and PEN

    NASA Astrophysics Data System (ADS)

    Weick, Brian L.

    2016-05-01

    Complex dynamic-compliance and in-phase dynamic-viscosity data are presented and analyzed for PET and PEN advanced polyester substrates used for magnetic tapes. Frequency-temperature superposition is used to predict long-term behavior. Temperature and frequency ranges for the primary glass transition and secondary transitions are discussed and compared for PET and PEN. Shift factors from frequency-temperature superposition are used to determine activation energies for the transitions, and WLF parameters are determined for the polyester substrates.

  1. Dynamic-compliance and viscosity of PET and PEN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weick, Brian L.

    Complex dynamic-compliance and in-phase dynamic-viscosity data are presented and analyzed for PET and PEN advanced polyester substrates used for magnetic tapes. Frequency-temperature superposition is used to predict long-term behavior. Temperature and frequency ranges for the primary glass transition and secondary transitions are discussed and compared for PET and PEN. Shift factors from frequency-temperature superposition are used to determine activation energies for the transitions, and WLF parameters are determined for the polyester substrates.

  2. SCUT: clinical data organization for physicians using pen computers.

    PubMed Central

    Wormuth, D. W.

    1992-01-01

    The role of computers in assisting physicians with patient care is rapidly advancing. One of the significant obstacles to efficient use of computers in patient care has been the unavailability of reasonably configured portable computers. Lightweight portable computers are becoming more attractive as physician data-management devices, but still pose a significant problem with bedside use. The advent of computers designed to accept input from a pen and having no keyboard present a usable computer platform to enable physicians to perform clinical computing at the bedside. This paper describes a prototype system to maintain an electronic "scut" sheet. SCUT makes use of pen-input and background rule checking to enhance patient care. GO Corporation's PenPoint Operating System is used to implement the SCUT project. PMID:1483012

  3. Injection Force of SoloSTAR® Compared with Other Disposable Insulin Pen Devices at Constant Volume Flow Rates

    PubMed Central

    van der Burg, Thomas

    2011-01-01

    Background Injection force is a particularly important practical aspect of therapy for patients with diabetes, especially those who have dexterity problems. This laboratory-based study compared the injection force of the SoloSTAR® insulin pen (SoloSTAR; sanofi-aventis) versus other available disposable pens at injection speeds based on the delivered volume of insulin released at the needle. Method Four different prefilled disposable pens were tested: SoloSTAR containing insulin glargine; FlexPen® and the Next Generation FlexPen® (NGFP) (Novo Nordisk), both containing insulin detemir; and KwikPen® containing insulin lispro (Eli Lilly). All pens were investigated using the maximum dispense volume for each pen type [80 units (U) for SoloSTAR; 60 U for the other pens], from the free needle tip dispensing into a beaker. Twenty pens of each type were fitted with the recommended needles and tested at two dose speeds (6 and 10 U/s); each pen was tested twice. Results Mean plateau injection force and maximum injection force were consistently lower with SoloSTAR compared with FlexPen, NGFP, and KwikPen at both injection speeds tested. An injection speed of 10 U/s was associated with higher injection force compared with 6 U/s for all the pens tested (p < .001). Conclusions SoloSTAR stands out because of its low injection force, even when compared with newer insulin pen devices such as the KwikPen and NGFP. This may enable patients, especially those with dexterity problems, to administer insulin more easily and improve management of their diabetes. PMID:21303637

  4. Multiple-locus variable number of tandem repeat analysis (MLVA) of Irish verocytotoxigenic Escherichia coli O157 from feedlot cattle: uncovering strain dissemination routes.

    PubMed

    Murphy, Mary; Minihan, Donal; Buckley, James F; O'Mahony, Micheál; Whyte, Paul; Fanning, Séamus

    2008-01-24

    The identification of the routes of dissemination of Escherichia coli (E. coli) O157 through a cohort of cattle is a critical step to control this pathogen at farm level. The aim of this study was to identify potential routes of dissemination of E. coli O157 using Multiple-Locus Variable number of tandem repeat Analysis (MLVA). Thirty-eight environmental and sixteen cattle faecal isolates, which were detected in four adjacent pens over a four-month period were sub-typed. MLVA could separate these isolates into broadly defined clusters consisting of twelve MLVA types. Strain diversity was observed within pens, individual cattle and the environment. Application of MLVA is a broadly useful and convenient tool when applied to uncover the dissemination of E. coli O157 in the environment and in supporting improved on-farm management of this important pathogen. These data identified diverse strain types based on amplification of VNTR markers in each case.

  5. Effect of calcium hydroxide application to cattle feedlot pens on Escherichia coli O157:H7 and total E. coli in pen surface manure

    USDA-ARS?s Scientific Manuscript database

    Introduction: Cattle and beef products are sources of the pathogen Escherichia coli O157:H7. Lime products have a long history of use in cattle production as disinfectants for sick pens, calving pens, and muddy areas, to control the spread of diseases. Lime may also be useful as a preharvest trea...

  6. MR-Tandem: parallel X!Tandem using Hadoop MapReduce on Amazon Web Services

    PubMed Central

    Pratt, Brian; Howbert, J. Jeffry; Tasman, Natalie I.; Nilsson, Erik J.

    2012-01-01

    Summary: MR-Tandem adapts the popular X!Tandem peptide search engine to work with Hadoop MapReduce for reliable parallel execution of large searches. MR-Tandem runs on any Hadoop cluster but offers special support for Amazon Web Services for creating inexpensive on-demand Hadoop clusters, enabling search volumes that might not otherwise be feasible with the compute resources a researcher has at hand. MR-Tandem is designed to drop in wherever X!Tandem is already in use and requires no modification to existing X!Tandem parameter files, and only minimal modification to X!Tandem-based workflows. Availability and implementation: MR-Tandem is implemented as a lightly modified X!Tandem C++ executable and a Python script that drives Hadoop clusters including Amazon Web Services (AWS) Elastic Map Reduce (EMR), using the modified X!Tandem program as a Hadoop Streaming mapper and reducer. The modified X!Tandem C++ source code is Artistic licensed, supports pluggable scoring, and is available as part of the Sashimi project at http://sashimi.svn.sourceforge.net/viewvc/sashimi/trunk/trans_proteomic_pipeline/extern/xtandem/. The MR-Tandem Python script is Apache licensed and available as part of the Insilicos Cloud Army project at http://ica.svn.sourceforge.net/viewvc/ica/trunk/mr-tandem/. Full documentation and a windows installer that configures MR-Tandem, Python and all necessary packages are available at this same URL. Contact: brian.pratt@insilicos.com PMID:22072385

  7. Pen-based computers: Computers without keys

    NASA Technical Reports Server (NTRS)

    Conklin, Cheryl L.

    1994-01-01

    The National Space Transportation System (NSTS) is comprised of many diverse and highly complex systems incorporating the latest technologies. Data collection associated with ground processing of the various Space Shuttle system elements is extremely challenging due to the many separate processing locations where data is generated. This presents a significant problem when the timely collection, transfer, collation, and storage of data is required. This paper describes how new technology, referred to as Pen-Based computers, is being used to transform the data collection process at Kennedy Space Center (KSC). Pen-Based computers have streamlined procedures, increased data accuracy, and now provide more complete information than previous methods. The end results is the elimination of Shuttle processing delays associated with data deficiencies.

  8. Measurement of the Neutron Lifetime Using a Proton Trap

    NASA Astrophysics Data System (ADS)

    Dewey, M. S.; Gilliam, D. M.; Nico, J. S.; Wietfeldt, F. E.; Fei, X.; Snow, W. M.; Greene, G. L.; Pauwels, J.; Eykens, R.; Lamberty, A.; van Gestel, J.

    2003-10-01

    We report a new measurement of the neutron decay lifetime by the absolute counting of in-beam neutrons and their decay protons. Protons were confined in a quasi-Penning trap and counted with a silicon detector. The neutron beam fluence was measured by capture in a thin 6LiF foil detector with known absolute efficiency. The combination of these simultaneous measurements gives the neu­tron lifetime: τn=(886.8±1.2[stat]±3.2[syst]) s. The systematic uncertainty is dominated by uncertainties in the mass of the 6LiF deposit and the 6Li(n,t) cross section. This is the most precise measurement of the neutron lifetime to date using an in-beam method.

  9. Pen Pal Writing: A Holistic and Socio-Cultural Approach to Adult English Literacy

    ERIC Educational Resources Information Center

    Larrotta, Clarena; Serrano, Arlene F.

    2012-01-01

    This qualitative study reports the findings implementing a pen pal letter exchange project between adult English language learners and volunteer native English speakers. The pen pal project was implemented using a holistic and socio-cultural approach to English literacy development. This article presents pen pal writing as an authentic language…

  10. Chemical composition of felt-tip pen inks.

    PubMed

    Germinario, Giulia; Garrappa, Silvia; D'Ambrosio, Valeria; van der Werf, Inez Dorothé; Sabbatini, Luigia

    2018-01-01

    Felt-tip pens are frequently used for the realization of sketches, drawings, architectural projects, and other technical designs. The formulations of these inks are usually rather complex and may be associated to those of modern paint materials where, next to the binding medium and pigments/dyes, solvents, fillers, emulsifiers, antioxidants, plasticizers, light stabilizers, biocides, and so on are commonly added. Felt-tip pen inks are extremely sensitive to degradation and especially exposure to light may cause chromatic changes and fading. In this study, we report on the complete chemical characterization of modern felt-tip pen inks that are commercially available and commonly used for the realization of artworks. Three brands of felt-tip pens (Faber-Castell, Edding, and Stabilo) were investigated with complementary analytical techniques such as thin-layer chromatography (TLC), VIS-reflectance spectroscopy, μ-Raman spectroscopy, surface-enhanced Raman spectroscopy (SERS), pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS), GC-MS, and Fourier transform infrared (FTIR) spectroscopy. The use of TLC proved to be very powerful in the study of complex mixtures of synthetic dyes. First derivatives of the reflectance spectra acquired on the TLC spots were useful in the preliminary identification of the dye, followed by Raman spectroscopy and SERS, which allowed for the unambiguous determination of the chemical composition of the pigments (phthalocyanines, dioxazines, and azo pigments) and dyes (azo dyes, triarylmethanes, xanthenes). FTIR spectroscopy was used especially for the detection of additives, as well as for confirming the nature of solvents and dyes/pigments. Finally, (Py-)GC-MS data provided information on the binders (styrene-acrylic resins, plant gums), solvents, and additives, as well as on pigments and dyes.

  11. A novel pen-based Bluetooth-enabled insulin delivery system with insulin dose tracking and advice.

    PubMed

    Bailey, Timothy S; Stone, Jenine Y

    2017-05-01

    Diabetes is growing in prevalence internationally. As more individuals require insulin as part of their treatment, technology evolves to optimize delivery, improve adherence, and reduce dosing errors. Insulin pens outperform vial and syringe in simplicity, dosing accuracy, and user preference. Bolus advisors improve dosing confidence and treatment adherence. The InPen System offers a novel approach to treatment via a wireless pen that syncs to a mobile application featuring a bolus advisor, enabling convenient insulin dose tracking and more accurate bolus advice among other features. Areas covered: Existing technology for insulin delivery and bolus advice are reviewed. The mechanics and functionality of the InPen device are delineated. Findings from formative testing and usability studies of the InPen system are reported. Future directions for the InPen system in the treatment of diabetes are discussed. Expert opinion: Diabetes management is complex and largely data-driven. The InPen System offers a promising new opportunity to avail insulin pen-users of features known to improve treatment efficacy, which have otherwise primarily been available to those using pumps. Given that the majority of insulin users do not use insulin pumps, the InPen System is poised to improve glucose control in a significant portion of the diabetes population.

  12. A redesigned follitropin alfa pen injector for infertility: results of a market research study

    PubMed Central

    Abbotts, Carole; Salgado-Braga, Cristiana; Audibert-Gros, Céline

    2011-01-01

    Background: The purpose of this study was to evaluate patient-learning and nurse-teaching experiences when using a redesigned prefilled, ready-to-use follitropin alfa pen injector. Methods: Seventy-three UK women of reproductive age either administering daily treatment with self-injectable gonadotropins or about to start gonadotropin treatment for infertility (aged 24–47 years; 53 self-injection-experienced and 20 self-injection-naïve) and 28 nurses from UK infertility clinics were recruited for the study. Following instruction, patients and nurses used the redesigned follitropin alfa pen to inject water into an orange and completed questionnaires to evaluate their experiences with the pen immediately after the simulated injections. Results: Most (88%, n = 64) patients found it easy to learn how to use the pen. Among injection-experienced patients, 66% (n = 35) agreed that the redesigned pen was easier to learn to use compared with their current method and 70% (n = 37) also said they would prefer its use over current devices for all injectable fertility medications. All nurses considered the redesigned pen easy to learn and believed it would be easy to teach patients how to use. Eighty-six percent (n = 24) of the nurses thought it was easy to teach patients to determine the remaining dose to be dialed and injected in a second pen if the initial dose was incomplete. Compared with other injection devices, 96% (n = 27) thought it was “much easier” to “as easy” to teach patients to use the redesigned pen. Based on ease of teaching, 68% (n = 19) of nurses would choose to teach the pen in preference to any other injection method. Almost all (93%, n = 26) nurses considered that having the same pen format for a range of injectable gonadotropins would facilitate teaching and learning self-injection. Conclusion: In this market research study with infertile patients and infertility nurses, the redesigned follitropin alfa pen was perceived as easy to learn, easy to

  13. Microchemical Pen: An Open Microreactor for Region-Selective Surface Modification.

    PubMed

    Mao, Sifeng; Sato, Chiho; Suzuki, Yuma; Yang, Jianmin; Zeng, Hulie; Nakajima, Hizuru; Yang, Ming; Lin, Jin-Ming; Uchiyama, Katsumi

    2016-10-18

    Various micro surface-modification approaches including photolithography, dip-pen lithography and ink-jet systems have been developed and used to extend the functionalities of solid surfaces. While those approaches work in the "open space", push-pull systems which work in solutions have recently drawn considerable attention. However, the confining flows performed by push-pull systems have realized only the dispense process, while microscale, region-selective chemical reactions have remained unattainable. This study reports a microchemical pen that enables region-selective chemical reactions for the micro surface modification/patterning. The chemical pen is based on the principle of microfluidic laminar flows and the resulting mixing of reagents by the mutual diffusion. The tiny diffusion layer performs as the working region. This report represents the first demonstration of an open microreactor in which two different reagents react on a real solid sample. The multifunctional characteristics of the microchemical pen are confirmed by different types of reactions in many research areas, including inorganic chemistry, polymer science, electrochemistry and biological sample treatment. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. An Investigation of the Usability of the Stylus Pen for Various Age Groups on Personal Digital Assistants

    ERIC Educational Resources Information Center

    Ren, Xiangshi; Zhou, Xiaolei

    2011-01-01

    Many handheld devices with stylus pens are available in the market; however, there have been few studies which examine the effects of the size of the stylus pen on user performance and subjective preferences for handheld device interfaces for various age groups. Two experiments (pen-length experiment and pen-tip width/pen-width experiment) were…

  15. Analysis of the NovoTwist Pen Needle in Comparison with Conventional Screw-Thread Needles

    PubMed Central

    Aye, Tandy

    2011-01-01

    Administration of insulin via a pen device may be advantageous over a vial and syringe system. Hofman and colleagues introduce a new insulin pen needle, the NovoTwist, to simplify injections to a small group of children and adolescents. Their overall preferences and evaluation of the handling of the needle are reported in the study. This new needle has the potential to ease administration of insulin via a pen device that may increase both the use of a pen device and adherence to insulin therapy. PMID:22226270

  16. Experimental research on showing automatic disappearance pen handwriting based on spectral imaging technology

    NASA Astrophysics Data System (ADS)

    Su, Yi; Xu, Lei; Liu, Ningning; Huang, Wei; Xu, Xiaojing

    2016-10-01

    Purpose to find an efficient, non-destructive examining method for showing the disappearing words after writing with automatic disappearance pen. Method Using the imaging spectrometer to show the potential disappearance words on paper surface according to different properties of reflection absorbed by various substances in different bands. Results the disappeared words by using different disappearance pens to write on the same paper or the same disappearance pen to write on different papers, both can get good show results through the use of the spectral imaging examining methods. Conclusion Spectral imaging technology can show the disappearing words after writing by using the automatic disappearance pen.

  17. Using a Digital Pen to Support Secondary Students with Learning Disabilities

    ERIC Educational Resources Information Center

    Ok, Min Wook; Rao, Kavita

    2017-01-01

    Secondary students with learning disabilities (LD) can benefit from using assistive and instructional technologies to support content and skill acquisition. Digital pens have features that can be beneficial for students who struggle with comprehension, note taking, and organization. Livescribe pens, in particular, provide a variety features that…

  18. Pen rearing and imprinting of fall Chinook salmon

    USGS Publications Warehouse

    Beeman, J.W.; Novotny, J.F.

    1994-01-01

    Results of rearing upriver bright fall chinook salmon juveniles in net pens and a barrier net enclosure in two backwater areas and a pond along the Columbia River were compared with traditional hatchery methods. Growth, smoltification, and general condition of pen-reared fish receiving supplemental feeding were better than those of fish reared using traditional methods. Juvenile fish receiving no supplemental feeding were generally in poor condition resulting in a net loss of production. Rearing costs using pens were generally lower than in the hatchery. However, low adult returns resulted in greater cost per adult recovery than fish reared and released using traditional methods. Much of the differences in recovery rates may have been due to differences in rearing locations, as study sites were as much as 128 mi upstream from the hatcheries and study fish may have incurred higher mortality associated with downstream migration than control fish. Fish reared using these methods could be a cost-effective method of enhancing salmon production in the Columbia River Basin.

  19. Automation of nanoflow liquid chromatography-tandem mass spectrometry for proteome analysis by using a strong cation exchange trap column.

    PubMed

    Jiang, Xiaogang; Feng, Shun; Tian, Ruijun; Han, Guanghui; Jiang, Xinning; Ye, Mingliang; Zou, Hanfa

    2007-02-01

    An approach was developed to automate sample introduction for nanoflow LC-MS/MS (microLC-MS/MS) analysis using a strong cation exchange (SCX) trap column. The system consisted of a 100 microm id x 2 cm SCX trap column and a 75 microm id x 12 cm C18 RP analytical column. During the sample loading step, the flow passing through the SCX trap column was directed to waste for loading a large volume of sample at high flow rate. Then the peptides bound on the SCX trap column were eluted onto the RP analytical column by a high salt buffer followed by RP chromatographic separation of the peptides at nanoliter flow rate. It was observed that higher performance of separation could be achieved with the system using SCX trap column than with the system using C18 trap column. The high proteomic coverage using this approach was demonstrated in the analysis of tryptic digest of BSA and yeast cell lysate. In addition, this system was also applied to two-dimensional separation of tryptic digest of human hepatocellular carcinoma cell line SMMC-7721 for large scale proteome analysis. This system was fully automated and required minimum changes on current microLC-MS/MS system. This system represented a promising platform for routine proteome analysis.

  20. Innovation & evaluation of tangible direct manipulation digital drawing pens for children.

    PubMed

    Lee, Tai-Hua; Wu, Fong-Gong; Chen, Huei-Tsz

    2017-04-01

    Focusing on the theme of direct manipulation, in this study, we proposed a new and innovative tangible user interface (TUI) design concept for a manipulative digital drawing pen. Based on interviews with focus groups brainstorming and experts and the results of a field survey, we selected the most suitable tangible user interface for children between 4 and 7 years of age. Using the new tangible user interface, children could choose between the brush tools after touching and feeling the various patterns. The thickness of the brush could be adjusted by changing the tilt angle. In a subsequent experimental process we compared the differences in performance and subjective user satisfaction. A total of sixteen children, aged 4-7 years participated in the experiment. Two operating system experiments (the new designed tangible digital drawing pen and traditional visual interface-icon-clicking digital drawing pens) were performed at random and in turns. We assessed their manipulation performance, accuracy, brush stroke richness and subjective evaluations. During the experimental process we found that operating functions using the direct manipulation method, and adding shapes and semantic models to explain the purpose of each function, enabled the children to perform stroke switches relatively smoothly. By using direct manipulation digital pens, the children could improve their stroke-switching performance for digital drawing. Additionally, by using various patterns to represent different brushes or tools, the children were able to make selections using their sense of touch, thereby reducing the time required to move along the drawing pens and select icons (The significant differences (p = 0.000, p < 0.01) existed in the manipulation times for drawing thick lines using the crayon function of the two (new and old) drawing pens (new 5.8750 < old 10.7500)). The addition of direct manipulation movements to drawing operations enhanced the drawing results, thereby

  1. Analysis of the NovoTwist pen needle in comparison with conventional screw-thread needles.

    PubMed

    Aye, Tandy

    2011-11-01

    Administration of insulin via a pen device may be advantageous over a vial and syringe system. Hofman and colleagues introduce a new insulin pen needle, the NovoTwist, to simplify injections to a small group of children and adolescents. Their overall preferences and evaluation of the handling of the needle are reported in the study. This new needle has the potential to ease administration of insulin via a pen device that may increase both the use of a pen device and adherence to insulin therapy. © 2011 Diabetes Technology Society.

  2. Increasing viscosity and inertia using a robotically-controlled pen improves handwriting in children

    PubMed Central

    Ben-Pazi, Hilla; Ishihara, Abraham; Kukke, Sahana; Sanger, Terence D

    2010-01-01

    The aim of this study was to determine the effect of mechanical properties of the pen on the quality of handwriting in children. Twenty two school aged children, ages 8–14 years wrote in cursive using a pen attached to a robot. The robot was programmed to increase the effective weight (inertia) and stiffness (viscosity) of the pen. Speed, frequency, variability, and quality of the two handwriting samples were compared. Increased inertia and viscosity improved handwriting quality in 85% of children (p<0.05). Handwriting quality did not correlate with changes in speed, suggesting that improvement was not due to reduced speed. Measures of movement variability remained unchanged, suggesting that improvement was not due to mechanical smoothing of pen movement by the robot. Since improvement was not explained by reduced speed or mechanical smoothing, we conclude that children alter handwriting movements in response to pen mechanics. Altered movement could be caused by changes in proprioceptive sensory feedback. PMID:19794098

  3. Functional Evaluation of the Reusable JuniorSTAR® Half-Unit Insulin Pen.

    PubMed

    Klonoff, David; Nayberg, Irina; Rabbone, Ivana; Domenger, Catherine; Stauder, Udo; Oualali, Hamid; Danne, Thomas

    2015-05-01

    The functional performance of the JuniorSTAR(®) (Sanofi, Paris, France) half-unit insulin pen was evaluated through a series of specific objective tests to assess the dose accuracy, pen weight, injection force, and dialing torque. Pens (n = 60) were tested under standard atmospheric conditions with 3 different types of insulins manufactured by Sanofi (insulin glargine, insulin glulisine, and biphasic insulin isophane). The dose accuracy was tested according to the ISO 11608-1:2012 standards. Injection doses of 0.010, 0.155, and 0.300 ml were evaluated. For mean weight evaluation, the pens without the cartridge were weighed on precision balances. The injection force was measured using a texture analyzer and the dialing torque was measured using a torque meter. JuniorSTAR met the ISO 11608-1:2012 criteria for dose accuracy as all the delivered doses were within the predefined limits for all types of insulin tested. The mean weight of the JuniorSTAR pen was 33.4 g (SD = 0.075). The mean injection force was 6.0 N (SD = 0.8), 4.3 N (SD = 0.4), and 5.1 N (SD = 0.6) for insulin glargine, insulin glulisine, and biphasic insulin isophane, respectively. The mean dialing torque was 5.09 Ncm (SD = 0.29) and 5.88 Ncm (SD = 0.53) for setting and correcting a dose, respectively. Together with results from a previously reported usability survey, these results show that the JuniorSTAR reusable, half-unit pen is a lightweight and accurate device for insulin delivery with a dialing torque and injection force suitable for young people with type 1 diabetes. © 2015 Diabetes Technology Society.

  4. Functional Evaluation of the Reusable JuniorSTAR® Half-Unit Insulin Pen

    PubMed Central

    Klonoff, David; Nayberg, Irina; Rabbone, Ivana; Domenger, Catherine; Stauder, Udo; Oualali, Hamid; Danne, Thomas

    2015-01-01

    Background: The functional performance of the JuniorSTAR® (Sanofi, Paris, France) half-unit insulin pen was evaluated through a series of specific objective tests to assess the dose accuracy, pen weight, injection force, and dialing torque. Method: Pens (n = 60) were tested under standard atmospheric conditions with 3 different types of insulins manufactured by Sanofi (insulin glargine, insulin glulisine, and biphasic insulin isophane). The dose accuracy was tested according to the ISO 11608-1:2012 standards. Injection doses of 0.010, 0.155, and 0.300 ml were evaluated. For mean weight evaluation, the pens without the cartridge were weighed on precision balances. The injection force was measured using a texture analyzer and the dialing torque was measured using a torque meter. Results: JuniorSTAR met the ISO 11608-1:2012 criteria for dose accuracy as all the delivered doses were within the predefined limits for all types of insulin tested. The mean weight of the JuniorSTAR pen was 33.4 g (SD = 0.075). The mean injection force was 6.0 N (SD = 0.8), 4.3 N (SD = 0.4), and 5.1 N (SD = 0.6) for insulin glargine, insulin glulisine, and biphasic insulin isophane, respectively. The mean dialing torque was 5.09 Ncm (SD = 0.29) and 5.88 Ncm (SD = 0.53) for setting and correcting a dose, respectively. Conclusions: Together with results from a previously reported usability survey, these results show that the JuniorSTAR reusable, half-unit pen is a lightweight and accurate device for insulin delivery with a dialing torque and injection force suitable for young people with type 1 diabetes. PMID:25633967

  5. Pen size and parity effects on maternal behaviour of Small-Tail Han sheep.

    PubMed

    Lv, S-J; Yang, Y; Dwyer, C M; Li, F-K

    2015-07-01

    The aim of this experiment was to study the effects of pen size and parity on maternal behaviour of twin-bearing Small-Tail Han ewes. A total of 24 ewes were allocated to a 2×2 design (six per pen), with parity (primiparous or multiparous) and pen size (large: 6.0×3.0 m; small: 6.0×1.5 m) as main effects at Linyi University, Shandong Province, China. Behaviour was observed from after parturition until weaning. All ewes were observed for 6 h every 5 days from 0700 to1000 h and from 1400 to 1700 h. Continuous focal animal sampling was used to quantify the duration of maternal behaviours: sucking, grooming and following as well as the frequency of udder accepting, udder refusing and low-pitched bleating. Oestradiol and cortisol concentrations in the faeces (collected in the morning every 5 days) were detected using EIA kits. All lambs were weighed 24 h after parturition and again at weaning at 35 days of age. The small pen size significantly reduced following (P<0.005), grooming (P<0.001) and suckling durations (P<0.05), as well as the frequency of udder refusals (P<0.001). However, there was a significant interaction with ewe parity, with decreased grooming and suckling in the small pen largely seen in the multiparous ewes (P<0.001). Independent of pen size, multiparous ewes accepted more sucking attempts by their lambs (P<0.05) and made more low-pitched bleats than primiparous ewes (P<0.001). Multiparous ewes had higher faecal oestradiol concentrations than primiparous ewes (P<0.001), and ewes in small pens had higher faecal cortisol levels compared with ewes in larger pens (P<0.001). As lambs increased in age, the duration of maternal grooming, following and suckling as well as frequency of udder acceptance and low-pitched bleating all declined, and the frequency of udder refusing increased (P<0.001 for all). Ewe parity, but not pen size, affected lamb weight gain during the period of observation (P<0.001). This is the first study to show that pen size

  6. Pen Textures Can Get "Hairy"

    ERIC Educational Resources Information Center

    Laird, Shirley

    2010-01-01

    The author likes to have her middle school students work with pens, patterns and textures. Because she was tired of the usual texture project she had been using, Shirley Laird began looking for a new approach. While searching for an inspiration, she ran across some old calendars that had excellent photos of teddy bears dressed up in different…

  7. Pen-Enabled, Real-Time Student Engagement for Teaching in STEM Subjects

    ERIC Educational Resources Information Center

    Urban, Sylvia

    2017-01-01

    The introduction of pen-enabling devices has been demonstrated to increase a student's ability to solve problems, communicate, and learn during note taking. For the science, technology, engineering, and mathematics subjects that are considered to be symbolic in nature, pen interfaces are better suited for visual-spatial content and also provide a…

  8. A Generic Approach for Pen-Based User Interface Development

    NASA Astrophysics Data System (ADS)

    Macé, Sébastien; Anquetil, Éric

    Pen-based interaction is an intuitive way to realize hand drawn structured documents, but few applications take advantage of it. Indeed, the interpretation of the user hand drawn strokes in the context of document is a complex problem. In this paper, we propose a new generic approach to develop such systems based on three independent components. The first one is a set of graphical and editing functions adapted to pen interaction. The second one is a rule-based formalism that models structured document composition and the corresponding interpretation process. The last one is a hand drawn stroke analyzer that is able to interpret strokes progressively, directly while the user is drawing. We highlight in particular the human-computer interaction induced from this progressive interpretation process. Thanks to this generic approach, three pen-based system prototypes have already been developed, for musical score editing, for graph editing, and for UML class diagram editing

  9. BluePen Biomarkers LLC: integrated biomarker solutions

    PubMed Central

    Blair, Ian A; Mesaros, Clementina; Lilley, Patrick; Nunez, Matthew

    2016-01-01

    BluePen Biomarkers provides a unique comprehensive multi-omics biomarker discovery and validation platform. We can quantify, integrate and analyze genomics, proteomics, metabolomics and lipidomics biomarkers, alongside clinical data, demographics and other phenotypic data. A unique bio-inspired signal processing analytic approach is used that has the proven ability to identify biomarkers in a wide variety of diseases. The resulting biomarkers can be used for diagnosis, prognosis, mechanistic studies and predicting treatment response, in contexts from core research through clinical trials. BluePen Biomarkers provides an additional groundbreaking research goal: identifying surrogate biomarkers from different modalities. This not only provides new biological insights, but enables least invasive, least-cost tests that meet or exceed the predictive quality of current tests. PMID:28031971

  10. Phosphorylation is required for the pathogen defense function of the Arabidopsis PEN3 ABC transporter

    USDA-ARS?s Scientific Manuscript database

    The Arabidopsis PEN3 ABC transporter accumulates at sites of pathogen detection, where it is involved in defense against multiple pathogens. Perception of PAMPs by pattern recognition receptors initiates recruitment of PEN3 and also leads to PEN3 phosphorylation at multiple amino acid residues. Whet...

  11. Product Plan of New Generation System Camera "OLYMPUS PEN E-P1"

    NASA Astrophysics Data System (ADS)

    Ogawa, Haruo

    "OLYMPUS PEN E-P1", which is new generation system camera, is the first product of Olympus which is new standard "Micro Four-thirds System" for high-resolution mirror-less cameras. It continues good sales by the concept of "small and stylish design, easy operation and SLR image quality" since release on July 3, 2009. On the other hand, the half-size film camera "OLYMPUS PEN" was popular by the concept "small and stylish design and original mechanism" since the first product in 1959 and recorded sale number more than 17 million with 17 models. By the 50th anniversary topic and emotional value of the Olympus pen, Olympus pen E-P1 became big sales. I would like to explain the way of thinking of the product plan that included not only the simple functional value but also emotional value on planning the first product of "Micro Four-thirds System".

  12. Effects of lignite application on ammonia and nitrous oxide emissions from cattle pens.

    PubMed

    Sun, Jianlei; Bai, Mei; Shen, Jianlin; Griffith, David W T; Denmead, Owen T; Hill, Julian; Lam, Shu Kee; Mosier, Arvin R; Chen, Deli

    2016-09-15

    Beef cattle feedlots are a major source of ammonia (NH3) emissions from livestock industries. We investigated the effects of lignite surface applications on NH3 and nitrous oxide (N2O) emissions from beef cattle feedlot pens. Two rates of lignite, 3 and 6kgm(-2), were tested in the treatment pen. No lignite was applied in the control pen. Twenty-four Black Angus steers were fed identical commercial rations in each pen. We measured NH3 and N2O concentrations continuously from 4th Sep to 13th Nov 2014 using Quantum Cascade Laser (QCL) NH3 analysers and a closed-path Fourier Transform Infrared Spectroscopy analyser (CP-FTIR) in conjunction with the integrated horizontal flux method to calculate NH3 and N2O fluxes. During the feeding period, 16 and 26% of the excreted nitrogen (N) (240gNhead(-1)day(-1)) was lost via NH3 volatilization from the control pen, while lignite application decreased NH3 volatilization to 12 and 18% of the excreted N, for Phase 1 and Phase 2, respectively. Compared to the control pen, lignite application decreased NH3 emissions by approximately 30%. Nitrous oxide emissions from the cattle pens were small, 0.10 and 0.14gN2O-Nhead(-1)day(-1) (<0.1% of excreted N) for the control pen, for Phase 1 and Phase 2, respectively. Lignite application increased direct N2O emissions by 40 and 57%, to 0.14 and 0.22gN2O-Nhead(-1)day(-1), for Phase 1 and Phase 2, respectively. The increase in N2O emissions resulting from lignite application was counteracted by the lower indirect N2O emission due to decreased NH3 volatilization. Using 1% as a default emission factor of deposited NH3 for indirect N2O emissions, the application of lignite decreased total N2O emissions. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Ballpoint pen ingestion in a 2-year-old child.

    PubMed

    Rameau, Anaïs; Anand, Sumeet M; Nguyen, Lily H

    2011-07-01

    A 2-year-old girl ingested a ballpoint pen, which was found on chest x-ray to have lodged in the lower esophagus and stomach. The pen, which measured nearly 15 cm in length, was removed via rigid esophagoscopy without complication. To the best of our knowledge, this is the longest nonflexible foreign body ingested by a young child ever reported in the English-language literature. We describe the presentation of this case and the current guidelines for safety as enumerated in the Small Parts Regulations established by the U.S. Consumer Product Safety Commission.

  14. Bulk derivatization and direct injection of human cerebrospinal fluid for trace-level quantification of endogenous estrogens using trap-and-elute liquid chromatography with tandem mass spectrometry.

    PubMed

    Fan, Hui; Papouskova, Barbora; Lemr, Karel; Wigginton, Jane G; Schug, Kevin A

    2014-08-01

    Although there are existing methods for determining estrogen in human bodily fluids including blood plasma and serum, very little information is available regarding estrogen levels in human cerebrospinal fluid (CSF), which is critical to assess in studies of neuroprotective functions and diffusion of neuroprotective estrogens across the blood-brain barrier. To address this problem, a liquid chromatography with tandem mass spectrometry method for the simultaneous quantification of four endogenous estrogens (estrone, 17α-estradiol, 17β-estradiol, and estriol) in human CSF was developed. An aliquot (300 μL) of human CSF was bulk derivatized using dansyl chloride in the sample and 10 μL was directly injected onto a restricted-access media trap column for protein removal. No off-line sample extraction or cleanup was needed. The limits of detection of estrone, 17α-estradiol, 17β-estradiol, and estriol were 17, 28, 13, and 30 pg/mL, respectively, which is in the parts-per-trillion regime. The method was then applied to human CSF collected from ischemic trauma patients. Endogenous estrogens were detected and quantified, demonstrating the effectiveness of this method. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Examining Factors That Impact Inpatient Management of Diabetes and the Role of Insulin Pen Devices.

    PubMed

    Smallwood, Chelsea; Lamarche, Danièle; Chevrier, Annie

    2017-02-01

    Insulin administration in the acute care setting is an integral component of inpatient diabetes management. Although some institutions have moved to insulin pen devices, many acute care settings continue to employ the vial and syringe method of insulin administration. The aim of this study was to evaluate the impact of insulin pen implementation in the acute care setting on patients, healthcare workers and health resource utilization. A review of published literature, including guidelines, was conducted to identify how insulin pen devices in the acute care setting may impact inpatient diabetes management. Previously published studies have revealed that insulin pen devices have the potential to improve inpatient management through better glycemic control, increased adherence and improved self-management education. Furthermore, insulin pen devices may result in cost savings and improved safety for healthcare workers. There are benefits to the use of insulin pen devices in acute care and, as such, their implementation should be considered. Copyright © 2016 Becton Dickinson Canada Inc. Published by Elsevier Inc. All rights reserved.

  16. Electrospray ionization tandem mass spectrometry of ammonium cationized polyethers.

    PubMed

    Nasioudis, Andreas; Heeren, Ron M A; van Doormalen, Irene; de Wijs-Rot, Nicolette; van den Brink, Oscar F

    2011-05-01

    Quaternary ammonium salts (Quats) and amines are known to facilitate the MS analysis of high molar mass polyethers by forming low charge state adduct ions. The formation, stability, and behavior upon collision-induced dissociation (CID) of adduct ions of polyethers with a variety of Quats and amines were studied by electrospray ionization quadrupole time-of-flight, quadrupole ion trap, and linear ion trap tandem mass spectrometry (MS/MS). The linear ion trap instrument was part of an Orbitrap hybrid mass spectrometer that allowed accurate mass MS/MS measurements. The Quats and amines studied were of different degree of substitution, structure, and size. The stability of the adduct ions was related to the structure of the cation, especially the amine's degree of substitution. CID of singly/doubly charged primary and tertiary ammonium cationized polymers resulted in the neutral loss of the amine followed by fragmentation of the protonated product ions. The latter reveals information about the monomer unit, polymer sequence, and endgroup structure. In addition, the detection of product ions retaining the ammonium ion was observed. The predominant process in the CID of singly charged quaternary ammonium cationized polymers was cation detachment, whereas their doubly charged adduct ions provided the same information as the primary and tertiary ammonium cationized adduct ions. This study shows the potential of specific amines as tools for the structural elucidation of high molar mass polyethers. © American Society for Mass Spectrometry, 2011

  17. Isobar Separation in a Multiple-Reflection Time-of-Flight Mass Spectrometer by Mass-Selective Re-Trapping.

    PubMed

    Dickel, Timo; Plaß, Wolfgang R; Lippert, Wayne; Lang, Johannes; Yavor, Mikhail I; Geissel, Hans; Scheidenberger, Christoph

    2017-06-01

    A novel method for (ultra-)high-resolution spatial mass separation in time-of-flight mass spectrometers is presented. Ions are injected into a time-of-flight analyzer from a radio frequency (rf) trap, dispersed in time-of-flight according to their mass-to-charge ratios and then re-trapped dynamically in the same rf trap. This re-trapping technique is highly mass-selective and after sufficiently long flight times can provide even isobaric separation. A theoretical treatment of the method is presented and the conditions for optimum performance of the method are derived. The method has been implemented in a multiple-reflection time-of-flight mass spectrometer and mass separation powers (FWHM) in excess of 70,000, and re-trapping efficiencies of up to 35% have been obtained for the protonated molecular ion of caffeine. The isobars glutamine and lysine (relative mass difference of 1/4000) have been separated after a flight time of 0.2 ms only. Higher mass separation powers can be achieved using longer flight times. The method will have important applications, including isobar separation in nuclear physics and (ultra-)high-resolution precursor ion selection in multiple-stage tandem mass spectrometry. Graphical Abstract ᅟ.

  18. Isobar Separation in a Multiple-Reflection Time-of-Flight Mass Spectrometer by Mass-Selective Re-Trapping

    NASA Astrophysics Data System (ADS)

    Dickel, Timo; Plaß, Wolfgang R.; Lippert, Wayne; Lang, Johannes; Yavor, Mikhail I.; Geissel, Hans; Scheidenberger, Christoph

    2017-06-01

    A novel method for (ultra-)high-resolution spatial mass separation in time-of-flight mass spectrometers is presented. Ions are injected into a time-of-flight analyzer from a radio frequency (rf) trap, dispersed in time-of-flight according to their mass-to-charge ratios and then re-trapped dynamically in the same rf trap. This re-trapping technique is highly mass-selective and after sufficiently long flight times can provide even isobaric separation. A theoretical treatment of the method is presented and the conditions for optimum performance of the method are derived. The method has been implemented in a multiple-reflection time-of-flight mass spectrometer and mass separation powers (FWHM) in excess of 70,000, and re-trapping efficiencies of up to 35% have been obtained for the protonated molecular ion of caffeine. The isobars glutamine and lysine (relative mass difference of 1/4000) have been separated after a flight time of 0.2 ms only. Higher mass separation powers can be achieved using longer flight times. The method will have important applications, including isobar separation in nuclear physics and (ultra-)high-resolution precursor ion selection in multiple-stage tandem mass spectrometry. [Figure not available: see fulltext.

  19. The human tartrate-resistant acid phosphatase (TRAP): involvement of the hemin responsive elements (HRE) in transcriptional regulation.

    PubMed

    Fleckenstein, E C; Dirks, W G; Drexler, H G

    2000-02-01

    The biochemical properties and protein structure of the tartrate-resistant acid phosphatase (TRAP), an iron-containing lysosomal glycoprotein in cells of the mononuclear phagocyte system, are well known. In contrast, little is known about the physiology and genic structure of this unique enzyme. In some diseases, like hairy cell leukemia, Gaucher's disease and osteoclastoma, cytochemically detected TRAP expression is used as a disease-associated marker. In order to begin to elucidate the regulation of this gene we generated different deletion constructs of the TRAP 5'-flanking region, placed them upstream of the luciferase reporter gene and assayed them for their ability to direct luciferase expression in human 293 cells. Treatment of these cells with the iron-modulating reagents transferrin and hemin causes opposite effects on the TRAP promoter activity. Two regulatory GAGGC tandem repeat sequences (the hemin responsive elements, HRE) within the 5'-flanking region of the human TRAP gene were identified. Studies with specific HRE-deletion constructs of the human TRAP 5'-flanking region upstream of the luciferase reporter gene document the functionality of these HRE-sequences which are apparently responsible for mediating transcriptional inhibition upon exposure to hemin. In addition to the previously published functional characterization of the murine TRAP HRE motifs, these results provide the first description of a new iron/hemin-responsive transcriptional regulation in the human TRAP gene.

  20. 78 FR 34392 - Guidance for Industry and Food and Drug Administration Staff: Technical Considerations for Pen...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-07

    ...] Guidance for Industry and Food and Drug Administration Staff: Technical Considerations for Pen, Jet, and... availability of a final guidance document entitled ``Technical Considerations for Pen, Jet, and Related... developing information to support a marketing application for a pen, jet, or related injector device intended...

  1. Microstructural control over soluble pentacene deposited by capillary pen printing for organic electronics.

    PubMed

    Lee, Wi Hyoung; Min, Honggi; Park, Namwoo; Lee, Junghwi; Seo, Eunsuk; Kang, Boseok; Cho, Kilwon; Lee, Hwa Sung

    2013-08-28

    Research into printing techniques has received special attention for the commercialization of cost-efficient organic electronics. Here, we have developed a capillary pen printing technique to realize a large-area pattern array of organic transistors and systematically investigated self-organization behavior of printed soluble organic semiconductor ink. The capillary pen-printed deposits of organic semiconductor, 6,13-bis(triisopropylsilylethynyl) pentacene (TIPS_PEN), was well-optimized in terms of morphological and microstructural properties by using ink with mixed solvents of chlorobenzene (CB) and 1,2-dichlorobenzene (DCB). Especially, a 1:1 solvent ratio results in the best transistor performances. This result is attributed to the unique evaporation characteristics of the TIPS_PEN deposits where fast evaporation of CB induces a morphological evolution at the initial printed position, and the remaining DCB with slow evaporation rate offers a favorable crystal evolution at the pinned position. Finally, a large-area transistor array was facilely fabricated by drawing organic electrodes and active layers with a versatile capillary pen. Our approach provides an efficient printing technique for fabricating large-area arrays of organic electronics and further suggests a methodology to enhance their performances by microstructural control of the printed organic semiconducting deposits.

  2. Adaptation of a 3-D Quadrupole Ion Trap for Dipolar DC Collisional Activation

    PubMed Central

    Prentice, Boone M.; Santini, Robert E.; McLuckey, Scott A.

    2011-01-01

    Means to allow for the application of a dipolar DC pulse to the end-cap electrodes of a three-dimensional (3-D) quadrupole ion trap for as short as a millisecond to as long as hundreds of milliseconds are described. The implementation of dipolar DC does not compromise the ability to apply AC waveforms to the end-cap electrodes at other times in the experiment. Dipolar DC provides a nonresonant means for ion acceleration by displacing ions from the center of the ion trap where they experience stronger rf electric fields, which increases the extent of micro-motion. The evolution of the product ion spectrum to higher generation products with time, as shown using protonated leucine enkephalin as a model protonated peptide, illustrates the broad-band nature of the activation. Dipolar DC activation is also shown to be effective as an ion heating approach in mimicking high amplitude short time excitation (HASTE)/pulsed Q dissociation (PQD) resonance excitation experiments that are intended to enhance the likelihood for observing low m/z products in ion trap tandem mass spectrometry. PMID:21953251

  3. Covalently Linked Tandem Lesions in DNA

    PubMed Central

    Patrzyc, Helen B.; Dawidzik, Jean B.; Budzinski, Edwin E.; Freund, Harold G.; Wilton, John H.; Box, Harold C.

    2013-01-01

    Reactive oxygen species (ROS) generate a type of DNA damage called tandem lesions, two adjacent nucleotides both modified. A subcategory of tandem lesions consists of adjacent nucleotides linked by a covalent bond. Covalently linked tandem lesions generate highly characteristic liquid chromotography-tandem mass spectrometry (LC-MS/MS) elution profiles. We have used this property to comprehensively survey X-irradiated DNA for covalently linked tandem lesions. A total of 15 tandem lesions were detected in DNA irradiated in deoxygenated aqueous solution, five tandem lesions were detected in DNA that was irradiated in oxygenated solution. PMID:23106212

  4. Smartphone Versus Pen-and-Paper Data Collection of Infant Feeding Practices in Rural China

    PubMed Central

    Zhang, Shuyi; Wu, Qiong; van Velthoven, Michelle HMMT; Chen, Li; Car, Josip; Rudan, Igor; Li, Ye; Scherpbier, Robert W

    2012-01-01

    Background Maternal, Newborn, and Child Health (MNCH) household survey data are collected mainly with pen-and-paper. Smartphone data collection may have advantages over pen-and-paper, but little evidence exists on how they compare. Objective To compare smartphone data collection versus the use of pen-and-paper for infant feeding practices of the MNCH household survey. We compared the two data collection methods for differences in data quality (data recording, data entry, open-ended answers, and interrater reliability), time consumption, costs, interviewers’ perceptions, and problems encountered. Methods We recruited mothers of infants aged 0 to 23 months in four village clinics in Zhaozhou Township, Zhao County, Hebei Province, China. We randomly assigned mothers to a smartphone or a pen-and-paper questionnaire group. A pair of interviewers simultaneously questioned mothers on infant feeding practices, each using the same method (either smartphone or pen-and-paper). Results We enrolled 120 mothers, and all completed the study. Data recording errors were prevented in the smartphone questionnaire. In the 120 pen-and-paper questionnaires (60 mothers), we found 192 data recording errors in 55 questionnaires. There was no significant difference in recording variation between the groups for the questionnaire pairs (P = .32) or variables (P = .45). The smartphone questionnaires were automatically uploaded and no data entry errors occurred. We found that even after double data entry of the pen-and-paper questionnaires, 65.0% (78/120) of the questionnaires did not match and needed to be checked. The mean duration of an interview was 10.22 (SD 2.17) minutes for the smartphone method and 10.83 (SD 2.94) minutes for the pen-and-paper method, which was not significantly different between the methods (P = .19). The mean costs per questionnaire were higher for the smartphone questionnaire (¥143, equal to US $23 at the exchange rate on April 24, 2012) than for the pen

  5. "My Pen Pal Goes to College": A Functional Approach to Literacy Learning.

    ERIC Educational Resources Information Center

    Yellin, David

    A study examined the effects of a "pen pal" letter writing exchange on undergraduate college students and second grade children. Subjects, 23 second graders, completed a letter writing attitude survey, and then (after receiving an explanation of what a pen pal is) exchanged letters with the undergraduates over a l5-week period. Results…

  6. Fast quantitative detection of cocaine in beverages using nanoextractive electrospray ionization tandem mass spectrometry.

    PubMed

    Hu, Bin; Peng, Xuejiao; Yang, Shuiping; Gu, Haiwei; Chen, Huanwen; Huan, Yanfu; Zhang, Tingting; Qiao, Xiaolin

    2010-02-01

    Without any sample pretreatment, effervescent beverage fluids were manually sprayed into the primary ion plume created by using a nanoelectrospray ionization source for direct ionization, and the analyte ions of interest were guided into an ion trap mass spectrometer for tandem mass analysis. Functional ingredients (e.g., vitamins, taurine, and caffeine, etc.) and spiked impurity (e.g., cocaine) in various beverages, such as Red Bull energy drink, Coco-cola, and Pepsi samples were rapidly identified within 1.5 s. The limit of detection was found to be 7-15 fg (S/N = 3) for cocaine in different samples using the characteristic fragment (m/z 150) observed in the MS(3) experiments. Typical relative standard deviation and recovery of this method were 6.9%-8.6% and 104%-108% for direct analysis of three actual samples, showing that nanoextractive electrospray ionization tandem mass spectrometry is a useful technique for fast screening cocaine presence in beverages. 2010. Published by Elsevier Inc.

  7. [Preference for etanercept pen versus syringe in patients with chronic arthritis. Nurse education workshop].

    PubMed

    Garcia-Diaz, Silvia; Girabent-Farrés, Montserrat; Roig-Vilaseca, Daniel; Reina, Delia; Cerdà, Dacia; González, Marina; Torrente-Segarra, Vicenç; Fíguls, Ramon; Corominas, Hèctor

    2013-01-01

    The aims of this study are to evaluate the level of fear of post-injection pain prior to the administration, the difficulty in handling the device, and the level of satisfaction of patients using a pre-filled syringe versus an etanercept pen, as well as to evaluate the usefulness of the training given by nursing staff prior to starting with the pen, and the preferences of patients after using both devices. A prospective study was designed to follow-up a cohort of patients during a 6 months period. The data was collected using questionnaires and analyzed with SPSS 18.00. Rank and McNemar tests were performed. Statistical significance was pre-set at an α level of 0.05. A total of 29 patients were included, of whom 69% female, and with a mean age 52.5±10.9 years. Of these, 48% had rheumatoid arthritis, 28% psoriatic arthritis, 21% ankylosing spondylitis, and 3% undifferentiated spondyloarthropathy. There were no statistically significant differences either with the fear or pain or handling of the device between the syringe and the pen (P=.469; P=.812; P=.169 respectively). At 6 months, 59% of patients referred to being satisfied or very satisfied with the pen. Almost all (93%) found useful or very useful the training given by nursing staff prior to using the pen, and 55% preferred the pen over the pre-filled syringe. The etanercept pen is another subcutaneous device option for patients with chronic arthritis. According to the present study, nursing educational workshops before starting this therapy are recommended. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  8. Getting to Know You: Cross-Cultural Pen Pals Expand Children's World View

    ERIC Educational Resources Information Center

    Shandomo, Hibajene M.

    2009-01-01

    In this article, the author described the Poplar Street-Naledi pen pal project. The goals of this project were to provide elementary school students with a broader view of the world, to increase their social and cultural awareness, to develop content knowledge of where their pen pals live, and to determine the impact of this project on student…

  9. Trap style influences wild pig behavior and trapping success

    USGS Publications Warehouse

    Williams, B.L.; Holtfreter, R.W.; Ditchkoff, S.S.; Grand, J.B.

    2011-01-01

    Despite the efforts of many natural resource professionals, wild pig (Sus scrofa) populations are expanding in many areas of the world. Although many creative techniques for controlling pig populations are being explored, trapping has been and still is themost commonly usedmethod of population control formany public and private land managers. We conducted an observational study to examine the efficiency of 2 frequently used trap styles: a small, portable box-style trap and a larger, semi-permanent, corral-style trap.We used game cameras to examine patterns of trap entry by wild pigs around each style of trap, and we conducted a trapping session to compare trapping success between trap styles. Adult female and juvenile wild pigs entered both styles of trap more readily than did adult males, and adult males seemed particularly averse to entering box traps. Less than 10% of adult male visits to box traps resulted in entries, easily the least percentage of any class at any style of trap. Adult females entered corral traps approximately 2.2 times more often per visit than box traps and re-entered corral traps >2 times more frequently. Juveniles entered and reentered both box and corral traps at similar rates. Overall (all-class) entry-per-visit rates at corral traps (0.71) were nearly double that of box traps (0.37). Subsequent trapping data supported these preliminary entry data; the capture rate for corral traps was >4 times that of box traps. Our data suggest that corral traps are temporally and economically superior to box traps with respect to efficiency; that is, corral traps effectively trap more pigs per trap night at a lower cost per pig than do box traps. ?? 2011 The Wildlife Society.

  10. Review of the High Performance Antiproton Trap (HiPAT) Experiment

    NASA Technical Reports Server (NTRS)

    Martin, James J.; Lewis, Raymond A.; Pearson, J. Boise; Sims, W. Herb; Chakrabarti, Suman; Fant, Wallace E.; McDonald, Stan

    2003-01-01

    Many space propulsion concepts exist that use matter-antimatter reactions. Current antiproton production rates are enough to conduct proof-of-principle evaluation of these concepts. One enabling technology for such experiments is portable storage of low energy antiprotons, to transport antiprotons to experimental facilities. To address this need, HiPAT is being developed, with a design goal of containing 10(exp 12) particles for up to 18 days. HiPAT is a Penning-Malmberg trap with a 4 Tesla superconductor, 20kV electrodes, radio frequency (RF) network, and 10(exp -13) Torr vacuum. 'Normal' matter is being used to evaluate the system. An electron beam ionizes background gas in situ, and particle beams are captured dynamically. The experiment examines ion storage lifetimes, RF plasma diagnostics, charge exchange with background gases, and dynamic ion beam capture.

  11. Planning and Teaching Report-Writing. PEN.

    ERIC Educational Resources Information Center

    Hayes, Julie

    Although an Australian educator had taught isolated aspects of functional grammar for a number of years, she felt that she had not put enough energy into building field (topic) knowledge. With the unit featured in this PEN Digest she aims to focus on building a quite extensive knowledge of the topic--snakes. According to the Digest, the educator…

  12. Accuracy and Injection Force of the Gla-300 Injection Device Compared With Other Commercialized Disposable Insulin Pens.

    PubMed

    Klonoff, David; Nayberg, Irina; Thonius, Marissa; See, Florian; Abdel-Tawab, Mona; Erbstein, Frank; Haak, Thomas

    2015-08-26

    To deliver insulin glargine 300 U/mL (Gla-300), the widely used SoloSTAR(®) pen has been modified to allow for accurate and precise delivery of required insulin units in one-third of the volume compared with insulin glargine 100 U/mL, while improving usability. Here we compare the accuracy and injection force of 3 disposable insulin pens: Gla-300 SoloSTAR(®), FlexPen(®), and KwikPen™. For the accuracy assessment, 60 of each of the 3 tested devices were used for the delivery of 3 different doses (1 U, half-maximal dose, and maximal dose), which were measured gravimetrically. For the injection force assessment, 20 pens of each of the 3 types were tested twice at half-maximal and once at maximal dose, at an injection speed of 6 U/s. All tested pens met the International Organization for Standardization (ISO) requirements for dosing accuracy, with Gla-300 SoloSTAR showing the lowest between-dose variation (greatest reproducibility) at all dose levels. Mean injection force was significantly lower for Gla-300 SoloSTAR than for the other 2 pens at both half maximal and maximal doses (P < .0271). All tested pens were accurate according to ISO criteria, and the Gla-300 SoloSTAR pen displayed the greatest reproducibility and lowest injection force of any of the 3 tested devices. © 2015 Diabetes Technology Society.

  13. Functionality of a novel follitropin alfa pen injector: results from human factor interactions by patients and nurses.

    PubMed

    Saunders, Helen; de la Fuente Bitaine, Laura; Eftekhar, Chriss; Howles, Colin M; Glaser, Johanna; Hoja, Tina; Arriagada, Pablo

    2018-06-01

    The main objective of this user experience testing study was to evaluate the impact of human factors on the use of a disposable pen containing follitropin alfa by patients and nurses with special focus on the convenience, safety and ease of use, in different types of stimulation protocols. Infertile women trying to conceive, and specialist nurses were recruited across 6 European countries. In total 18 patients and 19 nurses took part in the testing, which included both nurse-patient pairings and in-depth interviews. A standardized list of expected and pre-defined critical steps according to the Instructions for Use (IFU), was used to assess the correct handling of the pen. During the user experience testing, no critical errors, related to the use of the pen, which could affect the success of the injection process were identified. In general, both nurses and patients found the pen very easy to learn, use and would be confident using the pen for self-injection. Nurses also found the pen very easy to train the patients. The study provides valuable information on the pen from both patient and nurse perspectives in different simulated scenarios reflecting standard practice.

  14. Comparison of Data Acquisition Strategies on Quadrupole Ion Trap Instrumentation for Shotgun Proteomics

    PubMed Central

    Canterbury, Jesse D.; Merrihew, Gennifer E.; Goodlett, David R.; MacCoss, Michael J.; Shaffer, Scott A.

    2015-01-01

    A common strategy in mass spectrometry analyses of complex protein mixtures is to digest the proteins to peptides, separate the peptides by microcapillary liquid chromatography and collect tandem mass spectra (MS/MS) on the eluting, complex peptide mixtures, a process commonly termed “shotgun proteomics”. For years, the most common way of data collection was via data-dependent acquisition (DDA), a process driven by an automated instrument control routine that directs MS/MS acquisition from the highest abundant signals to the lowest, a process often leaving lower abundant signals unanalyzed and therefore unidentified in the experiment. Advances in both instrumentation duty cycle and sensitivity allow DDA to probe to lower peptide abundance and therefore enable mapping proteomes to a more significant depth. An alternative to acquiring data by DDA is by data-independent acquisition (DIA), in which a specified range in m/z is fragmented without regard to prioritization of a precursor ion or its relative abundance in the mass spectrum. As a consequence, DIA acquisition potentially offers more comprehensive analysis of peptides than DDA and in principle can yield tandem mass spectra of all ionized molecules following their conversion to the gas-phase. In this work, we evaluate both DDA and DIA on three different linear ion trap instruments: an LTQ, an LTQ modified in-house with an electrodynamic ion funnel, and an LTQ-Velos. These instruments were chosen as they are representative of both older (LTQ) and newer (LTQ-Velos) ion trap designs i.e., linear ion trap and dual ion traps, respectively, and allow direct comparison of peptide identification using both DDA and DIA analysis. Further, as the LTQ-Velos has an improved “S-lens” ion guide in the high-pressure region to improve ion flux, we found it logical to determine if the former LTQ model could be leveraged by improving sensitivity by modifying with an electrodynamic ion guide of significantly different

  15. Detection and determinants of Escherichia coli O157:H7 in Alberta feedlot pens immediately prior to slaughter

    PubMed Central

    Renter, David G.; Smith, David R.; King, Robin; Stilborn, Robert; Berg, Janice; Berezowski, John; McFall, Margaret

    2008-01-01

    Food safety risks due to Escherichia coli O157:H7 may be affected by variability in prevalence in or on live cattle at slaughter. Our objectives were to assess the prevalence and risk factors associated with E. coli O157:H7 in feedlot pens immediately prior to slaughter, and assess relationships among methods of monitoring the E. coli O157:H7 status of pre-harvest pens. We studied 84 pens containing a total of nearly 27 000 head of cattle in commercial feedlots in Alberta during 2003 and 2004. Sampling devices (ROPES) prepared from manila ropes were used to detect high prevalence pens. Forty of 84 pens (48%) were classified ROPES-positive. Within pens, fecal prevalence ranged between 0% to 80% (median = 20%) and the hide prevalence ranged between 0% and 30% (median = 0%). Pens that were ROPES-positive had a higher median prevalence for feces (40%) and for hides (3.8%) than those that were ROPES-negative (13.3% and 0%, respectively). The prevalence of E. coli O157:H7 in pens immediately prior to slaughter was found to be quite high or very low even within feedlots and seasons. Factors such as sampling month, temperature, precipitation, pen floor conditions, and water tank cleanliness were associated with E. coli O157:H7 outcome measures, although associated factors were not completely consistent among years and outcome measures. Fecal and hide prevalence are considered primary pre-harvest indicators of potential carcass contamination, but other methods such as ROPES that are associated with these outcomes may provide logistic advantages to efficiently classify pens of cattle as high or low risk to food safety. PMID:18505184

  16. Incidence and transmission of Mycoplasma bovis mastitis in Holstein dairy cows in a hospital pen: A case study.

    PubMed

    Punyapornwithaya, V; Fox, L K; Hancock, D D; Gay, J M; Wenz, J R; Alldredge, J R

    2011-01-01

    The objective was to determine the incidence and transmission of mycoplasma mastitis in the hospital pen in a dairy herd of 650 lactating cows after a hospital pen was established following an outbreak of this disease. Mycoplasma mastitis status was monitored for 3 months through repeated collection of milk samples from cows with clinical mastitis (CM) and from bulk tank milk. During the outbreak 13 cows were diagnosed with Mycoplasma bovis CM, 1 cow with Mycoplasma sp. mastitis and 8 cows showed signs of arthritis, 3 of which were confirmed as having M. bovis arthritis. M. bovis isolates from cows with CM, arthritis and bulk tank milk had indistinguishable chromosomal digest pattern fingerprints. Incidence rates of M. bovis CM cases in the milking and hospital pens were 0.01 and 1.7 cases per 100 cow-days at risk. Approximately 70% of cows with M. bovis CM became infected within 12 days of entering the hospital pen. Transmission of M. bovis in the hospital pen occurred as 3 episodes. Each episode corresponded to the introduction of a cow with M. bovis CM from a milking pen. Evidence indicates that cows with M. bovis CM from milking pens were the source of transmission of the disease in the hospital pen and thus their presence in the hospital pen appeared to be a risk factor for transmission of M. bovis mastitis in this single case study herd. Copyright © 2010 Elsevier B.V. All rights reserved.

  17. Magnetic field extraction of trap-based electron beams using a high-permeability grid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hurst, N. C.; Danielson, J. R.; Surko, C. M., E-mail: csurko@physics.ucsd.edu

    2015-07-15

    A method to form high quality electrostatically guided lepton beams is explored. Test electron beams are extracted from tailored plasmas confined in a Penning-Malmberg trap. The particles are then extracted from the confining axial magnetic field by passing them through a high magnetic permeability grid with radial tines (a so-called “magnetic spider”). An Einzel lens is used to focus and analyze the beam properties. Numerical simulations are used to model non-adiabatic effects due to the spider, and the predictions are compared with the experimental results. Improvements in beam quality are discussed relative to the use of a hole in amore » high permeability shield (i.e., in lieu of the spider), and areas for further improvement are described.« less

  18. Ecosystem Pen Pals: Using Place-Based Marine Science and Culture to Connect Students

    ERIC Educational Resources Information Center

    Wiener, Carlie S.; Matsumoto, Karen

    2014-01-01

    The marine environment provides a unique context for students to explore both natural and cultural connections. This paper reports preliminary findings on Ecosystem Pen Pals, an ocean literacy program for 4th and 5th graders focused on using a pen pal model for integrating traditional ecological knowledge into marine science. Surveys with…

  19. Orthogonal tandem catalysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lohr, Tracy L.; Marks, Tobin J.

    2015-05-20

    Tandem catalysis is a growing field that is beginning to yield important scientific and technological advances toward new and more efficient catalytic processes. 'One-pot' tandem reactions, where multiple catalysts and reagents, combined in a single reaction vessel undergo a sequence of precisely staged catalytic steps, are highly attractive from the standpoint of reducing both waste and time. Orthogonal tandem catalysis is a subset of one-pot reactions in which more than one catalyst is used to promote two or more mechanistically distinct reaction steps. This Perspective summarizes and analyses some of the recent developments and successes in orthogonal tandem catalysis, withmore » particular focus on recent strategies to address catalyst incompatibility. We also highlight the concept of thermodynamic leveraging by coupling multiple catalyst cycles to effect challenging transformations not observed in single-step processes, and to encourage application of this technique to energetically unfavourable or demanding reactions.« less

  20. The Influence of Trapped Particles on the Parametric Decay Instability of Near-Acoustic Waves

    NASA Astrophysics Data System (ADS)

    Affolter, M.; Anderegg, F.; Dubin, D. H. E.; Driscoll, C. F.

    2017-10-01

    We present quantitative measurements of a decay instability to lower frequencies of near-acoustic waves. These experiments are conducted on pure ion plasmas confined in a cylindrical Penning-Malmberg trap. The axisymmetric, standing plasma waves have near-acoustic dispersion, discretized by the axial wave number kz =mz(π /Lp) . The nonlinear coupling rates are measured between large amplitude mz = 2 (pump) waves and small amplitude mz = 1 (daughter) waves, which have a small frequency detuning Δω = 2ω1 -ω2 . Classical 3-wave parametric coupling rates are proportional to pump wave amplitude as Γ (δn2 /n0) , with oscillatory energy exchange for Γ < Δω / 2 and decay instability for Γ > Δω / 2 . Experiments on cold plasmas agree quantitatively for oscillatory energy exchange, and agree within a factor-of-two for decay instability rates. However, nascent theory suggest that this latter agreement is merely fortuitous, and that the instability mechanism is trapped particles. Experiments at higher temperatures show that trapped particles reduce the instability threshold below classical 3-wave theory predictions. Supported by NSF Grant PHY-1414570, and DOE Grants DE-SC0002451 and DE-SC0008693. M. Affolter is supported by the DOE FES Postdoctoral Research Program administered by ORISE for the DOE. ORISE is managed by ORAU under DOE Contract Number DE-SC0014664.

  1. Ex vivo evaluation of Tono-Pen and pneumotonometry in cat eyes.

    PubMed

    Stoiber, Josef; Fernandez, Viviana; Lamar, Peggy D; Hitzl, Wolfgang; Fantes, Francisco; Parel, Jean-Marie

    2006-01-01

    To evaluate the validity and intraobserver reliability of intraocular pressure (IOP) measurements with both pneumotonometry and the Tono-Pen in a closed ex vivo system in cat eyes. IOP was increased step by step in 5 enucleated cat eyes, while taking IOP measurements with the Tono-Pen and pneumotonometry. The outcomes were compared to readings of a digital manometer simultaneously measuring the actual pressure in the anterior chamber. Pneumotonometry overestimated IOP below 15 mm Hg and underestimated pressures above 20 mm Hg. Tono-Pen tonometry considerably underestimated IOP over the whole spectrum in all of the eyes tested. The pneumotonometer was identified as the more valid and reliable instrument for cat eyes. Both tonometers are clinically useful tools to assess IOP for glaucoma studies using a cat animal model. However, one has to consider underestimation of IOP in the upper ranges. A correction formula can be used to calculate the actual IOP.

  2. Use of Digital Pens for Rapid Epidemiologic Data Collection During a Foodborne Outbreak Investigation.

    PubMed

    Mathewson, Abigail A; Daly, Elizabeth R; Cavallo, Steffany J; Alic, Adnela

    2015-08-01

    Public health investigations require rapid assessment, response, and initiation of control measures. In 2012, the New Hampshire Department of Health and Human Services used digital pens to rapidly acquire epidemiologic data during a gastrointestinal illness outbreak. Menus were obtained and a standard questionnaire was administered to exposed persons using digital pens. Questionnaire data were downloaded into an electronic file for analysis. Sixty-nine (74%) of 93 exposed persons completed a questionnaire. Of 6389 data entries made on digital paper, 218 (3%) required correction; of these, 201 (92%) involved a free-form variable and 17 (8%) involved a check-box variable. Digital pens saved an estimated 5 to 6 hours of data-entry time. This outbreak provided an opportunity to assess the value of digital pens for decreasing data-entry burden and allowing more timely data analysis in an emergent setting. Depending on the size of the outbreak and complexity of the survey, there is likely a threshold when use of digital pens would provide a clear benefit to outbreak response. As new technology becomes available for use in emergency preparedness settings, public health agencies must continuously review and update response plans and evaluate investigation tools to ensure timely disease control and response activities.

  3. Recent H- diagnostics, plasma simulations, and 2X scaled Penning ion source developments at the Rutherford Appleton Laboratory

    NASA Astrophysics Data System (ADS)

    Lawrie, S. R.; Faircloth, D. C.; Smith, J. D.; Sarmento, T. M.; Whitehead, M. O.; Wood, T.; Perkins, M.; Macgregor, J.; Abel, R.

    2018-05-01

    A vessel for extraction and source plasma analyses is being used for Penning H- ion source development at the Rutherford Appleton Laboratory. A new set of optical elements including an einzel lens has been installed, which transports over 80 mA of H- beam successfully. Simultaneously, a 2X scaled Penning source has been developed to reduce cathode power density. The 2X source is now delivering a 65 mA H- ion beam at 10% duty factor, meeting its design criteria. The long-term viability of the einzel lens and 2X source is now being evaluated, so new diagnostic devices have been installed. A pair of electrostatic deflector plates is used to correct beam misalignment and perform fast chopping, with a voltage rise time of 24 ns. A suite of four quartz crystal microbalances has shown that the cesium flux in the vacuum vessel is only increased by a factor of two, despite the absence of a dedicated cold trap. Finally, an infrared camera has demonstrated good agreement with thermal simulations but has indicated unexpected heating due to beam loss on the downstream electrode. These types of diagnostics are suitable for monitoring all operational ion sources. In addition to experimental campaigns and new diagnostic tools, the high-performance VSim and COMSOL software packages are being used for plasma simulations of two novel ion thrusters for space propulsion applications. In parallel, a VSim framework has been established to include arbitrary temperature and cesium fields to allow the modeling of surface physics in H- ion sources.

  4. Participation in a mentored quality-improvement program for insulin pen safety: Opportunity to augment internal evaluation and share with peers.

    PubMed

    Rosenberg, Amy F

    2016-10-01

    UF Health's participation in a mentored quality-improvement impact program for health professionals as part of an ASHP initiative-"Strategies for Ensuring the Safe Use of Insulin Pens in the Hospital"-is described. ASHP invited hospitals to participate in its initiative at a time when UF Health was evaluating the risks and benefits of insulin pen use due to external reports of safety concerns and making a commitment to continue insulin pen use and optimize safeguards. Improvement opportunities in insulin pen best practices and staff education on insulin pen preparation and injection technique were identified and implemented. The storage of insulin pens for patients with contact isolation precautions was identified as a problem in certain patient care areas, and a practical solution was devised. Other process improvements included implementation of barcode medication administration, with scanning of insulin pens designated for specific patients to avoid inadvertent and intentional sharing of pens among multiple patients. Mentored calls with teams at other hospitals conducted as part of the program provided the opportunity to share experiences and solutions to improve insulin pen use. Participating with a knowledgeable mentor and other hospital teams struggling with the same issues and concerns related to safe insulin pen use facilitated problem solving. Discussing challenges and sharing ideas for solutions to safety concerns with other hospitals identified new process enhancements, which have the potential to improve the safety of insulin pen use at UF Health. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  5. Chemically stable Au nanorods as probes for sensitive surface enhanced scattering (SERS) analysis of blue BIC ballpoint pens

    NASA Astrophysics Data System (ADS)

    Alyami, Abeer; Saviello, Daniela; McAuliffe, Micheal A. P.; Cucciniello, Raffaele; Mirabile, Antonio; Proto, Antonio; Lewis, Liam; Iacopino, Daniela

    2017-08-01

    Au nanorods were used as an alternative to commonly used Ag nanoparticles as Surface Enhanced Raman Scattering (SERS) probes for identification of dye composition of blue BIC ballpoint pens. When used in combination with Thin Layer Chromatography (TLC), Au nanorod colloids allowed identification of the major dye components of the BIC pen ink, otherwise not identifiable by normal Raman spectroscopy. Thanks to their enhanced chemical stability compared to Ag colloids, Au nanorods provided stable and reproducible SERS signals and allowed easy identification of phthalocyanine and triarylene dyes in the pen ink mixture. These findings were supported by FTIR and MALDI analyses, also performed on the pen ink. Furthermore, the self-assembly of Au nanorods into large area ordered superstructures allowed identification of BIC pen traces. SERS spectra of good intensity and high reproducibility were obtained using Au nanorod vertical arrays, due to the high density of hot spots and morphological reproducibility of these superstructures. These results open the way to the employment of SERS for fast screening analysis and for quantitative analysis of pens and faded pens which are relevant for the fields of forensic and art conservation sciences.

  6. Measurement of Trap Length for an Optical Trap

    NASA Technical Reports Server (NTRS)

    Wrbanek, Susan Y.

    2009-01-01

    The trap length along the beam axis for an optical trap formed with an upright, oil-immersion microscope was measured. The goals for this effort were twofold. It was deemed useful to understand the depth to which an optical trap can reach for purposes of developing a tool to assist in the fabrication of miniature devices. Additionally, it was desired to know whether the measured trap length favored one or the other of two competing theories to model an optical trap. The approach was to trap a microsphere of known size and mass and raise it from its initial trap position. The microsphere was then dropped by blocking the laser beam for a pre-determined amount of time. Dropping the microsphere in a free-fall mode from various heights relative to the coverslip provides an estimate of how the trapping length changes with depth in water in a sample chamber on a microscope slide. While it was not possible to measure the trap length with sufficient precision to support any particular theory of optical trap formation, it was possible to find regions where the presence of physical boundaries influenced optical traps, and determine that the trap length, for the apparatus studied, is between 6 and 7 m. These results allow more precise control using optical micromanipulation to assemble miniature devices by providing information about the distance over which an optical trap is effective.

  7. Design and validation of the ball-pen probe for measurements in a low-temperature magnetized plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bousselin, G.; Cavalier, J.; Pautex, J. F.

    Ball-pen probes have been used in fusion devices for direct measurements of the plasma potential. Their application in low-temperature magnetized plasma devices is still subject to studies. In this context, a ball-pen probe has been recently implemented on the linear plasma device Mirabelle. Produced by a thermionic discharge, the plasma is characterized by a low electron temperature and a low density. Plasma confinement is provided by an axial magnetic field that goes up to 100 mT. The principle of the ball-pen probe is to adjust the saturation current ratio to 1 by reducing the electron current contribution. In that case,more » the floating potential of the probe is close to the plasma potential. A thorough study of the ball-pen probe operation is performed for different designs of the probe over a large set of plasma conditions. Comparisons between ball-pen, Langmuir, and emissive probes are conducted in the same plasma conditions. The ball-pen probe is successfully measuring the plasma potential in these specific plasma conditions only if an adapted electronics and an adapted probe size to the plasma characteristic lengths ({lambda}{sub D}, {rho}{sub ce}) are used.« less

  8. Role of penA polymorphisms for penicillin susceptibility in Neisseria lactamica and Neisseria meningitidis.

    PubMed

    Karch, André; Vogel, Ulrich; Claus, Heike

    2015-10-01

    In meningococci, reduced penicillin susceptibility is associated with five specific mutations in the transpeptidase region of penicillin binding protein 2 (PBP2). We showed that the same set of mutations was present in 64 of 123 Neisseria lactamica strains obtained from a carriage study (MIC range: 0.125-2.0mg/L). The PBP2 encoding penA alleles in these strains were genetically similar to those found in intermediate resistant meningococci suggesting frequent interspecies genetic exchange. Fifty-six N. lactamica isolates with mostly lower penicillin MICs (range: 0.064-0.38mg/L) exhibited only three of the five mutations. The corresponding penA alleles were unique to N. lactamica and formed a distinct genetic clade. PenA alleles with no mutations on the other hand were unique to meningococci. Under penicillin selective pressure, genetic transformation of N. lactamica penA alleles in meningococci was only possible for alleles encoding five mutations, but not for those encoding three mutations; the transfer resulted in MICs comparable to those of meningococci harboring penA alleles that encoded PBP2 with five mutations, but considerably lower than those of the corresponding N. lactamica donor strains. Due to a transformation barrier the complete N. lactamica penA could not be transformed into N. meningitidis. In summary, penicillin MICs in N. lactamica were associated with the number of mutations in the transpeptidase region of PBP2. Evidence for interspecific genetic transfer was only observed for penA alleles associated with higher MICs, suggesting that alleles encoding only three mutations in the transpeptidase region are biologically not effective in N. meningitidis. Factors other than PBP2 seem to be responsible for the high levels of penicillin resistance in N. lactamica. A reduction of penicillin susceptibility in N. meningitidis by horizontal gene transfer from N. lactamica is unlikely to happen. Copyright © 2015 Elsevier GmbH. All rights reserved.

  9. Pen confinement of yearling ewes with cows or heifers for 14 days to produce bonded sheep.

    PubMed

    Fredrickson, E L.; Anderson, D M.; Estell, R E.; Havstad, K M.; Shupe, W L.; Remmenga, M D.

    2001-06-01

    Mixed species stocking is commonly a more ecologically sound and efficient use of forage resources than single species stocking, especially in pastures having complex assemblages of forage species. However, in many environments livestock predation on especially smaller ruminants adds an extra challenge to mixed species stocking. When mixed sheep and cattle remain consistently as a cohesive group (flerd), predation risks are lessened, while fencing and herding costs are reduced. To establish a cohesive group (bond), a 30-day bonding period in which young sheep and cattle pairs are penned together is currently recommended. The purpose of this research was to test if a bond could be produced in <30 days (14 days) using pen confinement; thus reducing feed, labor, and overhead costs. Additionally, we tested whether cow age affects cohesiveness of bonded pairs immediately following 14 days of pen confinement. Sixteen mature cows (7-8 years of age) and sixteen 9-month-old heifers were randomly paired with one of 32 yearling ewe lambs. Eight cow/ewe (PC) and eight heifer/ewe (PH) pairs were maintained individually in 2mx6m pens for 14 days. The other eight-cow/ewe (NC) and heifer/ewe (NH) pairs were separated by species with each species maintained on separate pastures for the 14-day period. After 14 days, pairs were released in observation paddocks and separation distance between treatment pairs was measured during a 30-min open field test. Other behaviors were also noted and recorded during the field test. Separation distance did not differ (P=0.973) between the PC and PH treatments; however, separation distance for NC versus NH (P<0.004), NC versus PC (P<0.001), and NH versus PH (P<0.002) all differed. Mean separation distance (meters) and standard errors were 40+/-3.9, 3+/-0.3, 76+/-5.3, and 4+/-1.4 for NH, PH, NC, and PC treatments, respectively. Overall, the animals that were penned spent more time grazing and less time walking than animals not previously penned for

  10. Neisseria gonorrhoeae and extended-spectrum cephalosporins in California: surveillance and molecular detection of mosaic penA.

    PubMed

    Gose, Severin; Nguyen, Duylinh; Lowenberg, Daniella; Samuel, Michael; Bauer, Heidi; Pandori, Mark

    2013-12-04

    The spread of Neisseria gonorrhoeae strains with mosaic penA alleles and reduced susceptibility to extended-spectrum cephalosporins is a major public health problem. While much work has been performed internationally, little is known about the genetics or molecular epidemiology of N. gonorrhoeae isolates with reduced susceptibility to extended-spectrum cephalosporins in the United States. The majority of N. gonorrhoeae infections are diagnosed without a live culture. Molecular tools capable of detecting markers of extended-spectrum cephalosporin resistance are needed. Urethral N. gonorrhoeae isolates were collected from 684 men at public health clinics in California in 2011. Minimum inhibitory concentrations (MICs) to ceftriaxone, cefixime, cefpodoxime and azithromycin were determined by Etest and categorized according to the U.S. Centers for Disease Control 2010 alert value breakpoints. 684 isolates were screened for mosaic penA alleles using real-time PCR (RTPCR) and 59 reactive isolates were subjected to DNA sequencing of their penA alleles and Neisseria gonorrhoeae multi-antigen sequence typing (NG-MAST). To increase the specificity of the screening RTPCR in detecting isolates with alert value extended-spectrum cephalosporin MICs, the primers were modified to selectively amplify the mosaic XXXIV penA allele. Three mosaic penA alleles were detected including two previously described alleles (XXXIV, XXXVIII) and one novel allele (LA-A). Of the 29 isolates with an alert value extended-spectrum cephalosporin MIC, all possessed the mosaic XXXIV penA allele and 18 were sequence type 1407, an internationally successful strain associated with multi-drug resistance. The modified RTPCR detected the mosaic XXXIV penA allele in urethral isolates and urine specimens and displayed no amplification of the other penA alleles detected in this study. N. gonorrhoeae isolates with mosaic penA alleles and reduced susceptibility to extended-spectrum cephalosporins are currently

  11. Neisseria gonorrhoeae and extended-spectrum cephalosporins in California: surveillance and molecular detection of mosaic penA

    PubMed Central

    2013-01-01

    Background The spread of Neisseria gonorrhoeae strains with mosaic penA alleles and reduced susceptibility to extended-spectrum cephalosporins is a major public health problem. While much work has been performed internationally, little is known about the genetics or molecular epidemiology of N. gonorrhoeae isolates with reduced susceptibility to extended-spectrum cephalosporins in the United States. The majority of N. gonorrhoeae infections are diagnosed without a live culture. Molecular tools capable of detecting markers of extended-spectrum cephalosporin resistance are needed. Methods Urethral N. gonorrhoeae isolates were collected from 684 men at public health clinics in California in 2011. Minimum inhibitory concentrations (MICs) to ceftriaxone, cefixime, cefpodoxime and azithromycin were determined by Etest and categorized according to the U.S. Centers for Disease Control 2010 alert value breakpoints. 684 isolates were screened for mosaic penA alleles using real-time PCR (RTPCR) and 59 reactive isolates were subjected to DNA sequencing of their penA alleles and Neisseria gonorrhoeae multi-antigen sequence typing (NG-MAST). To increase the specificity of the screening RTPCR in detecting isolates with alert value extended-spectrum cephalosporin MICs, the primers were modified to selectively amplify the mosaic XXXIV penA allele. Results Three mosaic penA alleles were detected including two previously described alleles (XXXIV, XXXVIII) and one novel allele (LA-A). Of the 29 isolates with an alert value extended-spectrum cephalosporin MIC, all possessed the mosaic XXXIV penA allele and 18 were sequence type 1407, an internationally successful strain associated with multi-drug resistance. The modified RTPCR detected the mosaic XXXIV penA allele in urethral isolates and urine specimens and displayed no amplification of the other penA alleles detected in this study. Conclusion N. gonorrhoeae isolates with mosaic penA alleles and reduced susceptibility to extended

  12. Potential Insulin Underdelivery from Prefilled and Reusable Insulin Pens in Cases of Premature Needle Withdrawal: A Laboratory Evaluation.

    PubMed

    Joubert, Michael; Haddouche, Aini; Morera, Julia; Rod, Anne; Reznik, Yves

    2015-10-01

    Devices for the treatment of diabetes are not always used as recommended in good practice. Our aim was to evaluate potential insulin underdelivery in cases of premature needle withdrawal after injection with insulin pens, which is a commonly observed misuse, especially in young type 1 diabetes patients. Potential insulin underdelivery was evaluated using five prefilled insulin pens (lispro Kwikpen(®) [Eli Lilly, Indianapolis, IN], aspart Flexpen(®) [Novo Nordisk, Bagsvaerd, Denmark], glulisine Solostar(®) [Sanofi, Paris, France], detemir Flexpen(®) [Novo Nordisk], and glargine Solostar(®) [Sanofi]) and three reusable insulin pens (Humapen(®) Luxura HD with lispro cartridge [Eli Lilly], Novopen(®) Echo with aspart and detemir cartridge [Novo Nordisk], and JuniorSTAR(®) with glulisine and glargine cartridge [Sanofi]) in a laboratory. For each pen and insulin, we simulated premature needle withdrawal 2 and 3 s after an insulin injection of 5 and 10 units, respectively. With prefilled pens, mean potential insulin underdelivery was 0.43±0.30 and 0.44±0.32 units after injection of 5 and 10 units, respectively. With reusable pens, mean potential insulin underdelivery was lower (0.29±0.13 and 0.29±0.12 units after injection of 5 and 10 units, respectively; P<0.001). The results were heterogeneous across pens, ranging from 2.6%/1.6% to 20.2%/8.6% of the selected insulin dose for prefilled/reusable pens, respectively (P<0.001). Potential insulin underdelivery varies across prefilled and reusable insulin pens but may represent up to one-fifth of the total injected dose. Clinicians should be aware of the potential consequences of premature needle withdrawal and should reinforce insulin injection education.

  13. Nanoink bridge-induced capillary pen printing for chemical sensors.

    PubMed

    Kahng, Seong-Joong; Cerwyn, Chiew; Dincau, Brian M; Kim, Jong-Hoon; Novosselov, Igor V; Anantram, M P; Chung, Jae-Hyun

    2018-08-17

    Single-walled carbon nanotubes (SWCNTs) are used as a key component for chemical sensors. For miniature scale design, a continuous printing method is preferred for electrical conductance without damaging the substrate. In this paper, a non-contact capillary pen printing method is presented by the formation of a nanoink bridge between the nib of a capillary pen and a polyethylene terephthalate film. A critical parameter for stable printing is the advancing contact angle at the bridge meniscus, which is a function of substrate temperature and printing speed. The printed pattern including dots, lines, and films of SWCNTs are characterized by morphology, optical transparency, and electrical properties. Gas and pH sensors fabricated using the non-contact printing method are demonstrated as applications.

  14. Usage and Perceptions of Pen Injectors for Diabetes Management: A Survey of Type 2 Diabetes Patients in the United States

    PubMed Central

    Toscano, Deborah; Brice, Jennifer; Alfaro, Christina

    2012-01-01

    Background This study was conducted to investigate type 2 diabetes mellitus (T2DM) patient perceptions of their pen injectors and determine which features were deemed most important to overall satisfaction. Methods Frost & Sullivan conducted a Web-based survey of T2DM patients in the United States in November 2010. Survey participants were initially screened prior to full participation. A total of 1002 adult T2DM patients who were using a pen injector on a regular basis to administer their diabetes medication(s) were surveyed. The survey consisted of 24 questions focused on awareness and current usage of pen injectors by type and brand, specific features of pen injectors, and patients' preferences for and satisfaction with pen injectors. Results The majority of surveyed patients were using prefilled pen injectors as compared with durable pens. The LANTUS SoloSTAR (sanofi-aventis) was reported to be the most commonly used pen. The LANTUS SoloSTAR was also ranked highly for overall satisfaction and likelihood of continued usage. Regardless of brand, most surveyed patients reported that they were likely to continue using their current pen. In general, the single most important feature for user satisfaction was an easy push-button injection. Conclusions Ease of self-administration is of highest priority to users of pen injectors. Important features facilitating ease of use, such as an easily depressed push-button injection, are likely to minimize the burden on T2DM patients, thereby improving compliance and clinical outcomes. PMID:22768901

  15. Dosing Accuracy of Insulin Aspart FlexPens After Transport Through the Pneumatic Tube System.

    PubMed

    Ward, Leah G; Heckman, Michael G; Warren, Amy I; Tran, Kimberly

    2013-01-01

    The purpose of this study was to evaluate whether transporting insulin aspart FlexPens via a pneumatic tube system affects the dosing accuracy of the pens. A total of 115 Novo Nordisk FlexPens containing insulin aspart were randomly assigned to be transported via a pneumatic tube system (n = 92) or to serve as the control (n = 23). Each pen was then randomized to 10 international unit (IU) doses (n = 25) or 30 IU doses (n = 67), providing 600 and 603 doses, respectively, for the pneumatic tube group. The control group also received random assignment to 10 IU doses (n = 6) or 30 IU doses (n = 17), providing 144 and 153 doses, respectively. Each dose was expelled using manufacturer instructions. Weights were recorded, corrected for specific gravity, and evaluated based on acceptable International Organization for Standardization (ISO) dosing limits. In the group of pens transported through the pneumatic tube system, none of the 600 doses of 10 IU (0.0%; 95% CI, 0.0 to 0.6) and none of the 603 doses of 30 IU (0.0%; 95% CI, 0.0 to 0.6) fell outside of the range of acceptable weights. Correspondingly, in the control group, none of the 144 doses at 10 IU (0.0%; 95% CI, 0.0 to 2.5) and none of the 153 doses at 30 IU (0.0%; 95% CI, 0.0 to 2.4) were outside of acceptable ISO limits. Transportation via pneumatic tube system does not appear to compromise dosing accuracy. Hospital pharmacies may rely on the pneumatic tube system for timely and accurate transport of insulin aspart FlexPens.

  16. Temporally, spatially, and spectrally resolved barrier discharge produced in trapped helium gas at atmospheric pressure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chiper, Alina Silvia; Popa, Gheorghe

    2013-06-07

    Experimental study was made on induced effects by trapped helium gas in the pulsed positive dielectric barrier discharge (DBD) operating in symmetrical electrode configuration at atmospheric pressure. Using fast photography technique and electrical measurements, the differences in the discharge regimes between the stationary and the flowing helium are investigated. It was shown experimentally that the trapped gas atmosphere (TGA) has notable impact on the barrier discharge regime compared with the influence of the flowing gas atmosphere. According to our experimental results, the DBD discharge produced in trapped helium gas can be categorized as a multi-glow (pseudo-glow) discharge, each discharge workingmore » in the sub-normal glow regime. This conclusion is made by considering the duration of current pulse (few {mu}s), their maximum values (tens of mA), the presence of negative slope on the voltage-current characteristic, and the spatio-temporal evolution of the most representative excited species in the discharge gap. The paper focuses on the space-time distribution of the active species with a view to better understand the pseudo-glow discharge mechanism. The physical basis for these effects was suggested. A transition to filamentary discharge is suppressed in TGA mode due to the formation of supplementary source of seed electrons by surface processes (by desorption of electrons due to vibrationally excited nitrogen molecules, originated from barriers surfaces) rather than volume processes (by enhanced Penning ionisation). Finally, we show that the pseudo-glow discharge can be generated by working gas trapping only; maintaining unchanged all the electrical and constructive parameters.« less

  17. High-performance liquid chromatography with diode array detection coupled to electrospray time-of-flight and ion-trap tandem mass spectrometry to identify phenolic compounds from a lemon verbena extract.

    PubMed

    Quirantes-Piné, R; Funes, L; Micol, V; Segura-Carretero, A; Fernández-Gutiérrez, A

    2009-07-10

    High-performance liquid chromatography with diode array and electrospray ionization mass spectrometric detection was used to carry out the comprehensive characterization of a lemon verbena extract with demonstrated antioxidant and antiinflammatory activity. Two different MS techniques have been coupled to HPLC: on one hand, time-of-flight mass spectrometry, and on the other hand, tandem mass spectrometry on an ion-trap. The use of a small particle size C18 column (1.8 microm) provided a great resolution and made possible the separation of several isomers. The UV-visible spectrophotometry was used to delimit the class of phenolic compound and the accurate mass measurements on time-of-flight spectrometer enabled to identify the compounds present in the extract. Finally, the fragmentation pattern obtained in MS-MS experiments confirmed the proposed structures. This procedure was able to determine many well-known phenolic compounds present in lemon verbena such as verbascoside and its derivatives, diglucuronide derivatives of apigenin and luteolin, and eukovoside. Also gardoside, verbasoside, cistanoside F, theveside, campneoside I, chrysoeriol-7-diglucuronide, forsythoside A and acacetin-7-diglucuronide were found for the first time in lemon verbena.

  18. Some concepts of the advanced mass spectrometry at the COMBAS magnetic separator of nuclear reaction products

    NASA Astrophysics Data System (ADS)

    Artukh, A. G.; Tarantin, N. I.

    Proposed is an in-flight measurement method of recoil nuclei masses with the help of a Penning trap located behind the COMBAS magnetic separator for nuclear reaction products. The method is based on the following operations: (i) Accepting the recoil nuclear reaction products by the magnetic separator and decreasing their kinetic energy by degraders. (ii) In-flight transportation of the retarded nuclei into the magnetic field of the Penning trap's solenoid and transforming their remaining longitudinal momentum into orbital rotation by the fringing magnetic field of the solenoid. (iii) Cooling the orbital rotation of the ions by the high-frequency azimuthal electric field of the Penning trap's electric hyperboloid.

  19. Gender Representation in an Electronic City Hall: Female Adoption of Santa Monica's PEN System.

    ERIC Educational Resources Information Center

    Collins-Jarvis, Lori A.

    1993-01-01

    Discussion of the use of electronic networking systems by women focuses on a study of their use of the Public Electronic Network (PEN) in Santa Monica (California). Characteristics of PEN that contributed to female adoption are described; gender, political participation, and motivation are examined; and future research is suggested. (46…

  20. Growth of long triisopropylsilylethynyl pentacene (TIPS-PEN) nanofibrils in a polymer thin film during spin-coating.

    PubMed

    Park, Minwoo; Min, Yuho; Lee, Yu-Jeong; Jeong, Unyong

    2014-03-01

    This study demonstrates the growth of long triisopropylsilyethynyl pentacene (TIPS-PEN) nanofibrils in a thin film of a crystalline polymer, poly(ε-caprolactone) (PCL). During spin-coating, TIPS-PEN molecules are locally extracted around the PCL grain boundaries and they crystallize into [010] direction forming long nanofibrils. Molecular weight of PCL and weight fraction (α) of TIPS-PEN in PCL matrix are key factors to the growth of nanofibrils. Long high-quality TIPS-PEN nanofibrils are obtained with high-molecular-weight PCL and at the α values in the range of 0.03-0.1. The long nanofibrils are used as an active layer in a field-effect organic transistor. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Achieving 15% Tandem Polymer Solar Cells

    DTIC Science & Technology

    2015-06-23

    solar cell structures – both polymer only and hybrid tandem cells to constantly pushing the envelope of solution processed solar cell ...performance – 11.6% polymer tandem cell , 7% transparent tandem polymer cell , and over 10% PCE hybrid tandem solar cells were achieved. In addition, AFOSR’s...final support also enabled us to explore novel hybrid perovskite solar cells in depth. For example, single junction cell efficiency

  2. Technical note: whole-pen assessments of nutrient excretion and digestibility from dairy replacement heifers housed in sand-bedded freestalls.

    PubMed

    Coblentz, W K; Hoffman, P C; Esser, N M; Bertram, M G

    2013-10-01

    Our objectives were to describe and test refined procedures for quantifying excreta produced from whole pens of dairy heifers. Previous research efforts attempting to make whole-pen measurements of excreta output have been complicated by the use of organic bedding, which requires cumbersome analytical techniques to quantify excreta apart from the bedding. Research pens equipped with sand-bedded freestalls offer a unique opportunity for refinement of whole-pen fecal collection methods, primarily because sand-bedded freestall systems contain no organic bedding; therefore, concentrations of ash within the manure, sand, and feces can be used to correct for contamination of manure by sand bedding. This study was conducted on a subset of heifers from a larger production-scale feeding trial evaluating ensiled eastern gamagrass [Tripsacum dactyloides (L.) L.] haylage (EGG) that was incorporated into a corn silage/alfalfa haylage-based blended diet at rates of 0, 9.1, 18.3, or 27.4% of total DM. The diet without EGG also was offered on a limit-fed basis. Eighty Holstein dairy heifers were blocked (heavy weight, 424 ± 15.9 kg; light weight, 324 ± 22.4 kg) and then assigned to 10 individual pens containing 8 heifers/pen. One pen per block was assigned to each of the 5 research diets, and whole-pen fecal collections were conducted twice for each pen. Grab fecal samples also were gathered from individual heifers within each pen, and subsequent analysis of these whole-pen composites allowed reasonable estimates of OM and NDF excreta output. Under the conditions of our experimental design, pooled SEM for the excreta DM, OM, NDF, and NDF (ash corrected) output were 0.113, 0.085, 0.093, and 0.075 kg·heifer(-1)·d(-1), respectively. For DM excretion, this represented about one-third of the SEM reported for previous whole-pen collections from bedded-pack housing systems. Subsequent calculations of apparent DM and OM digestibilities indicated that the technique was sensitive, and

  3. Digital assist: A comparison of two note-taking methods (traditional vs. digital pen) for students with emotional behavioral disorders

    NASA Astrophysics Data System (ADS)

    Rody, Carlotta A.

    High school biology classes traditionally follow a lecture format to disseminate content and new terminology. With the inclusive practices of No Child Left Behind, the Common Core State Standards, and end-of-course exam requirement for high school diplomas, classes include a large range of achievement levels and abilities. Teachers assume, often incorrectly, that students come to class prepared to listen and take notes. In a standard diploma, high school biology class in a separate school for students with emotional and behavioral disorders, five students participated in a single-subject, alternating treatment design study that compared the use of regular pens and digital pens to take notes during 21 lecture sessions. Behavior measures were threefold between the two interventions: (a) quantity of notes taken per minute during lectures, (b) quantity of notes or notations taken during review pauses, and (c) percent of correct responses on the daily comprehension quizzes. The study's data indicated that two students were inclined to take more lecture notes when using the digital pen. Two students took more notes with the regular pen. One student demonstrated no difference in her performance with either pen type. Both female students took more notes per minute, on average, than the three males regardless of pen type. During the review pause, three of the five students only added notes or notations to their notes when using the regular pen. The remaining two students did not add to their notes. Quiz scores differed in favor of the regular pen. All five participants earned higher scores on quizzes given during regular pen sessions. However, the differences were minor, and recommendations are made for specific training in note-taking, the pause strategy, and digital pen fluency which may produce different results for both note-taking and quiz scores.

  4. A comparison of dosing accuracy: visually impaired and sighted people using insulin pens.

    PubMed

    Williams, Ann S; Schnarrenberger, Patrick A

    2010-05-01

    In the United States, 18% of people with diagnosed diabetes have visual impairment. Insulin pens are widely used by both blind and sighted people. However, major manufacturers include a disclaimer in the instructions warning against use by visually impaired people, without giving a rationale. Published studies neither support nor refute the disclaimer. The purpose of this study was to compare accuracy of dosing with insulin pens between visually impaired and sighted people. Inclusion criteria were self-reported diabetes and inability (visually impaired group) or ability (sighted group) to read regular print. The sole exclusion criterion was inability to pass a brief test of decisional capacity. Each participant received standardized instructions for insulin pen use, either in recorded (visually impaired group) or in printed (sighted group) format, and delivered 10 systematically varied doses into an injection ball, which was weighed on a precision laboratory balance. No significant correlation with accuracy of insulin dosing was found for any of the analyzed variables: visual status, age, gender, years of having diabetes mellitus (DM), or treatment of DM with or without insulin. This study provided preliminary evidence of the safety of use of insulin pens by visually impaired people and raised questions about the validity of the disclaimer. Further study of the safety of use of insulin pens by blind people is needed. Inclusion of people with disabilities in research on technology intended for patient use would ensure that people with disabilities can benefit from new technology. (c) 2010 Diabetes Technology Society.

  5. Transport of three veterinary antimicrobials from feedlot pens via simulated rainfall runoff.

    PubMed

    Sura, Srinivas; Degenhardt, Dani; Cessna, Allan J; Larney, Francis J; Olson, Andrew F; McAllister, Tim A

    2015-07-15

    Veterinary antimicrobials are introduced to wider environments by manure application to agricultural fields or through leaching or runoff from manure storage areas (feedlots, stockpiles, windrows, lagoons). Detected in manure, manure-treated soils, and surface and ground water near intensive cattle feeding operations, there is a concern that environmental contamination by these chemicals may promote the development of antimicrobial resistance in bacteria. Surface runoff and leaching appear to be major transport pathways by which veterinary antimicrobials eventually contaminate surface and ground water, respectively. A study was conducted to investigate the transport of three veterinary antimicrobials (chlortetracycline, sulfamethazine, tylosin), commonly used in beef cattle production, in simulated rainfall runoff from feedlot pens. Mean concentrations of veterinary antimicrobials were 1.4 to 3.5 times higher in surface material from bedding vs. non-bedding pen areas. Runoff rates and volumetric runoff coefficients were similar across all treatments but both were significantly higher from non-bedding (0.53Lmin(-1); 0.27) than bedding areas (0.40Lmin(-1); 0.19). In keeping with concentrations in pen surface material, mean concentrations of veterinary antimicrobials were 1.4 to 2.5 times higher in runoff generated from bedding vs. non-bedding pen areas. Water solubility and sorption coefficient of antimicrobials played a role in their transport in runoff. Estimated amounts of chlortetracycline, sulfamethazine, and tylosin that could potentially be transported to the feedlot catch basin during a one in 100-year precipitation event were 1.3 to 3.6ghead(-1), 1.9ghead(-1), and 0.2ghead(-1), respectively. This study demonstrates the magnitude of veterinary antimicrobial transport in feedlot pen runoff and supports the necessity of catch basins for runoff containment within feedlots. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  6. Prevalence of digital dermatitis in young stock in Alberta, Canada, using pen walks.

    PubMed

    Jacobs, C; Orsel, K; Barkema, H W

    2017-11-01

    Digital dermatitis (DD), an infectious bacterial foot lesion prevalent in dairy cattle worldwide, reduces both animal welfare and production. This disease was recently identified in replacement dairy heifers, with implications including increased risk of DD and decreased milk production in first lactation, poor reproductive performance, and altered hoof conformation. Therefore, a simple and effective method is needed to identify DD in young stock and to determine risk factors for DD in this group so that effective control strategies can be implemented. The objectives of this study were to (1) determine prevalence of DD in young stock (based on pen walks); and (2) identify potential risk factors for DD in young stock. A cross-sectional study was conducted on 28 dairy farms in Alberta, Canada; pen walks were used to identify DD (present/absent) on the hind feet of group-housed, young dairy stock. A subset of 583 young stock on 5 farms were selected for chute inspection of feet to determine the accuracy of pen walks for DD detection. Pen walks as a means of identifying DD lesions on the hind feet in young stock had sensitivity and specificity at the animal level of 65 and 98%, with positive and negative predictive values of 94 and 83%, respectively, at a prevalence of 37%. At the foot level, pen walks had sensitivity and specificity of 62 and 98%, respectively, with positive and negative predictive values of 92 and 88%, respectively, at a prevalence of 26%. Pen walks identified DD in 79 [2.9%; 95% confidence interval (95% CI): 2.3-3.6%] of 2,815 young stock on 11 (39%; 95% CI: 22-59%) of 28 farms, with all 79 DD-positive young stock ≥309 d of age. Apparent within-herd prevalence estimates ranged from 0 to 9.3%, with a mean of 1.4%. True within-herd prevalence of DD in young stock, calculated using the sensitivity and specificity of the pen walks, ranged from 0 to 12.6%, with a mean of 1.4%. On the 11 DD-positive farms, the proportion of young stock >12 mo of age

  7. Dose accuracy of a reusable insulin pen using a cartridge system with an integrated plunger mechanism.

    PubMed

    Clarke, Alastair; Dain, Marie-Paule

    2006-09-01

    Pen injection devices are a common method of administering insulin for patients with diabetes. Pen devices must comply with guidelines prepared by the International Organization for Standardization, which include device dose accuracy and precision. OptiClik (sanofi-aventis) was developed to fulfil unmet needs of patients with diabetes, including: easier cartridge changing, clearer dose display and readability, and a larger dose of insulin to be delivered with a single injection. In this paper, the authors report on the dose accuracy of the OptiClik pen device, which uses a novel cartridge system with an integrated plunger for easier cartridge changing. The authors show that OptiClik accurately delivers a required dose of insulin, which is maintained over the lifetime of the pen. OptiClik offers a significant contribution to the treatment of diabetes.

  8. Search for tensor-like couplings in the β-decay of laser trapped 6He

    NASA Astrophysics Data System (ADS)

    Leredde, Arnaud; Bailey, Kevin; Mueller, Peter; O'Connor, Tom; Bagdasarova, Yelena; Garcia, Alejandro; Hong, Ran; Sternberg, Matthew; Storm, Derek; Swanson, Erik; Wauters, Frederik; Zumwalt, David; Flechard, Xavier; Naviliat-Cuncic, Oscar

    2015-10-01

    The beta-neutrino angular correlation in nuclear beta decay can reveal the nature of the weak interaction. The case of 6He is particularly sensitive to test for tensor contributions by measuring the corresponding angular correlation parameter aβν. Trapping techniques such as magneto-optical traps (MOT) combined with recoil ion momentum spectroscopy are powerful tools which allow to measure aβν with high precision. The experiment, located at the University of Washington, takes advantage of the tandem Van de Graaff accelerator to produce up to 2×1010 6He/s. A double-MOT setup has been optimized to trap and detect beta-recoil-ion coincidences at a rate of a few Hertz. Systematic effects have been investigated in details and major effort has been put to limit their contribution to less than 1% of aβν. The first goal of this experiment is to measure aβν with this 1% uncertainty and use this set of data to guide further improvements with the goal to bring the uncertainty to the 0.1% level. The performances of the trap setup, preliminary coincidence data, and studies of systematic uncertainties will be presented. This work is supported by DOE, Office of Nuclear Physics, under Contract Nos. DE-AC02-06CH11357 and DE-FG02-97ER41020.

  9. The digital pen and paper technology: implementation and use in an existing clinical information system.

    PubMed

    Despont-Gros, Christelle; Bœuf, Christophe; Geissbuhler, Antoine; Lovis, Christian

    2005-01-01

    Evaluation of the technical feasibility of tight integration of the digital pen and paper technology in an existing computerized patient record.Technology: The digital pen is a normal pen able to record all actions of the user and to analyze a micro pattern printed on the paper. The digital paper is a normal paper printed with an almost invisible micro pattern of small dots encoding information such as position and identifiers. We report our experience in the implementation and the use of this technology in an existing large clinical information system for acquiring clinical information. It is possible to print uniquely identified forms using the digital paper technology. These forms can be pre-filled with clinical readable information about the patient. When care providers complete these forms using the digital pen, it is possible to acquire the data in a structured computerized patient record. The technology is easy to integrate in a component-based architecture based on Web Services. The digital pen and paper is a cost-effective technology that can be integrated in an existing clinical information system and allows fast and easy bedside clinical information acquisition without the need for an expensive infrastructure based on traditional portable devices or wireless devices.

  10. 50 CFR 697.19 - Trap limits and trap tag requirements for vessels fishing with lobster traps.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... vessels fishing with lobster traps. 697.19 Section 697.19 Wildlife and Fisheries FISHERY CONSERVATION AND... requirements for vessels fishing with lobster traps. (a) Area 1 trap limits. The Area 1 trap limit is 800 traps. Federally permitted lobster fishing vessels shall not fish with, deploy in, possess in, or haul back more...

  11. Time-of-flights and traps: from the Histone Code to Mars.

    PubMed

    Cotter, Robert J; Swatkoski, Stepehen; Becker, Luann; Evans-Nguyen, Theresa

    2010-01-01

    Two very different analytical instruments are featured in this perspective paper on mass spectrometer design and development. The first instrument, based upon the curved-field reflectron developed in the Johns Hopkins Middle Atlantic Mass Spectrometry Laboratory, is a tandem time-of-flight mass spectrometer whose performance and practicality are illustrated by applications to a series of research projects addressing the acetylation, deacetylation and ADP-ribosylation of histone proteins. The chemical derivatization of lysine-rich, hyperacetylated histones as their deuteroacetylated analogs enables one to obtain an accurate quantitative assessment of the extent of acetylation at each site. Chemical acetylation of histone mixtures is also used to determine the lysine targets of sirtuins, an important class of histone deacetylases (HDACs), by replacing the deacetylated residues with biotin. Histone deacetylation by sirtuins requires the co-factor NAD+, as does the attachment of ADP-ribose. The second instrument, a low voltage and low power ion trap mass spectrometer known as the Mars Organic Mass Analyzer (MOMA), is a prototype for an instrument expected to be launched in 2018. Like the tandem mass spectrometer, it is also expected to have applicability to environmental and biological analyses and, ultimately, to clinical care.

  12. Time-of-flights and traps: from the Histone Code to Mars*

    PubMed Central

    Swatkoski, Stephen; Becker, Luann; Evans-Nguyen, Theresa

    2011-01-01

    Two very different analytical instruments are featured in this perspective paper on mass spectrometer design and development. The first instrument, based upon the curved-field reflectron developed in the Johns Hopkins Middle Atlantic Mass Spectrometry Laboratory, is a tandem time-of-flight mass spectrometer whose performance and practicality are illustrated by applications to a series of research projects addressing the acetylation, deacetylation and ADP-ribosylation of histone proteins. The chemical derivatization of lysine-rich, hyperacetylated histones as their deuteroacetylated analogs enables one to obtain an accurate quantitative assessment of the extent of acetylation at each site. Chemical acetylation of histone mixtures is also used to determine the lysine targets of sirtuins, an important class of histone deacetylases (HDACs), by replacing the deacetylated residues with biotin. Histone deacetylation by sirtuins requires the co-factor NAD+, as does the attachment of ADP-ribose. The second instrument, a low voltage and low power ion trap mass spectrometer known as the Mars Organic Mass Analyzer (MOMA), is a prototype for an instrument expected to be launched in 2018. Like the tandem mass spectrometer, it is also expected to have applicability to environmental and biological analyses and, ultimately, to clinical care. PMID:20530839

  13. TANDEM: matching proteins with tandem mass spectra.

    PubMed

    Craig, Robertson; Beavis, Ronald C

    2004-06-12

    Tandem mass spectra obtained from fragmenting peptide ions contain some peptide sequence specific information, but often there is not enough information to sequence the original peptide completely. Several proprietary software applications have been developed to attempt to match the spectra with a list of protein sequences that may contain the sequence of the peptide. The application TANDEM was written to provide the proteomics research community with a set of components that can be used to test new methods and algorithms for performing this type of sequence-to-data matching. The source code and binaries for this software are available at http://www.proteome.ca/opensource.html, for Windows, Linux and Macintosh OSX. The source code is made available under the Artistic License, from the authors.

  14. The influence of facility and home pen design on the welfare of the laboratory-housed dog.

    PubMed

    Scullion Hall, Laura E M; Robinson, Sally; Finch, John; Buchanan-Smith, Hannah M

    We have an ethical and scientific obligation to Refine all aspects of the life of the laboratory-housed dog. Across industry there are many differences amongst facilities, home pen design and husbandry, as well as differences in features of the dogs such as strain, sex and scientific protocols. Understanding how these influence welfare, and hence scientific output is therefore critical. A significant proportion of dogs' lives are spent in the home pen and as such, the design can have a considerable impact on welfare. Although best practice guidelines exist, there is a paucity of empirical evidence to support the recommended Refinements and uptake varies across industry. In this study, we examine the effect of modern and traditional home pen design, overall facility design, husbandry, history of regulated procedures, strain and sex on welfare-indicating behaviours and mechanical pressure threshold. Six groups of dogs from two facilities (total n=46) were observed in the home pen and tested for mechanical pressure threshold. Dogs which were housed in a purpose-built modern facility or in a modern design home pen showed the fewest behavioural indicators of negative welfare (such as alert or pacing behaviours) and more indicators of positive welfare (such as resting) compared to those in a traditional home pen design or traditional facility. Welfare indicating behaviours did not vary consistently with strain, but male dogs showed more negative welfare indicating behaviours and had greater variation in these behaviours than females. Our findings showed more positive welfare indicating behaviours in dogs with higher mechanical pressure thresholds. We conclude that factors relating to the design of home pens and implementation of Refinements at the facility level have a significant positive impact on the welfare of laboratory-housed dogs, with a potential concomitant impact on scientific endpoints. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights

  15. Imaging MS Methodology for More Chemical Information in Less Data Acquisition Time Utilizing a Hybrid Linear Ion Trap-Orbitrap Mass Spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perdian, D. C.; Lee, Young Jin

    2010-11-15

    A novel mass spectrometric imaging method is developed to reduce the data acquisition time and provide rich chemical information using a hybrid linear ion trap-orbitrap mass spectrometer. In this method, the linear ion trap and orbitrap are used in tandem to reduce the acquisition time by incorporating multiple linear ion trap scans during an orbitrap scan utilizing a spiral raster step plate movement. The data acquisition time was decreased by 43-49% in the current experiment compared to that of orbitrap-only scans; however, 75% or more time could be saved for higher mass resolution and with a higher repetition rate laser.more » Using this approach, a high spatial resolution of 10 {micro}m was maintained at ion trap imaging, while orbitrap spectra were acquired at a lower spatial resolution, 20-40 {micro}m, all with far less data acquisition time. Furthermore, various MS imaging methods were developed by interspersing MS/MS and MSn ion trap scans during orbitrap scans to provide more analytical information on the sample. This method was applied to differentiate and localize structural isomers of several flavonol glycosides from an Arabidopsis flower petal in which MS/MS, MSn, ion trap, and orbitrap images were all acquired in a single data acquisition.« less

  16. Pen-on-paper strategy for point-of-care testing: Rapid prototyping of fully written microfluidic biosensor.

    PubMed

    Li, Zedong; Li, Fei; Xing, Yue; Liu, Zhi; You, Minli; Li, Yingchun; Wen, Ting; Qu, Zhiguo; Ling Li, Xiao; Xu, Feng

    2017-12-15

    Paper-based microfluidic biosensors have recently attracted increasing attentions in point-of-care testing (POCT) territories benefiting from their affordable, accessible and eco-friendly features, where technologies for fabricating such biosensors are preferred to be equipment free, easy-to-operate and capable of rapid prototyping. In this work, we developed a pen-on-paper (PoP) strategy based on two custom-made pens, i.e., a wax pen and a conductive-ink pen, to fully write paper-based microfluidic biosensors through directly writing both microfluidic channels and electrodes. Particularly, the proposed wax pen is competent to realize one-step fabrication of wax channels on paper, as the melted wax penetrates into paper during writing process without any post-treatments. The practical applications of the fabricated paper-based microfluidic biosensors are demonstrated by both colorimetric detection of Salmonella typhimurium DNA with detection limit of 1nM and electrochemical measurement of glucose with detection limit of 1mM. The developed PoP strategy for making microfluidic biosensors on paper characterized by true simplicity, prominent portability and excellent capability for rapid prototyping shows promising prospect in POCT applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. 10. Historic American Buildings Survey PEN & INK DRAWING BY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey PEN & INK DRAWING BY FRANCIS H. CRUESS (original drawing & full-size reproducible on file) after and oil painting of ca. 1860 - Johannes Luyster House, Laurel Avenue & Middleton Road, Holland, Monmouth County, NJ

  18. 42 CFR 414.104 - PEN Items and Services.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 3 2012-10-01 2012-10-01 false PEN Items and Services. 414.104 Section 414.104 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM (CONTINUED) PAYMENT FOR PART B MEDICAL AND OTHER HEALTH SERVICES Fee Schedules...

  19. 42 CFR 414.104 - PEN Items and Services.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 3 2013-10-01 2013-10-01 false PEN Items and Services. 414.104 Section 414.104 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM (CONTINUED) PAYMENT FOR PART B MEDICAL AND OTHER HEALTH SERVICES Fee Schedules...

  20. 42 CFR 414.104 - PEN Items and Services.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 3 2011-10-01 2011-10-01 false PEN Items and Services. 414.104 Section 414.104 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM PAYMENT FOR PART B MEDICAL AND OTHER HEALTH SERVICES Fee Schedules for...

  1. 42 CFR 414.104 - PEN Items and Services.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 3 2014-10-01 2014-10-01 false PEN Items and Services. 414.104 Section 414.104 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM (CONTINUED) PAYMENT FOR PART B MEDICAL AND OTHER HEALTH SERVICES Fee Schedules...

  2. 42 CFR 414.104 - PEN Items and Services.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false PEN Items and Services. 414.104 Section 414.104 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM PAYMENT FOR PART B MEDICAL AND OTHER HEALTH SERVICES Fee Schedules for...

  3. Photographic copy of undated 12” x 36” pen and ink ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photographic copy of undated 12” x 36” pen and ink drawing by Modjeski, Masters and Chase, Bridge Engineers. Illustrator Unknown. Loose in oversized box located at the National Museum of American History, Smithsonian Institution, Archives Center, Work and Industry Division, Washington, D.C. PEN AND INK DRAWING OF FINAL PROPOSAL OF “BRIDGE OVER THE MISSISSIPPI RIVER, NEW ORLEANS, LA.” - Huey P. Long Bridge, Spanning Mississippi River approximately midway between nine & twelve mile points upstream from & west of New Orleans, Jefferson, Jefferson Parish, LA

  4. Educational session as a tool to increase patient satisfaction of switching etanercept from the prefilled syringe to the autoinjection pen.

    PubMed

    Borrás-Blasco, Joaquín; Gracia-Pérez, Antonio; Casterá, M Dolores-Elvira; Rosique-Robles, J Dolores; Abad, Javier

    2013-08-01

    To assess patients' acceptability of switching etanercept from the prefilled syringe to the autoinjection pen in rheumatoid arthritis, psoriatic arthritis and ankylosing spondylitis patients. A two-phase cross-sectional study was designed. First phase: consisted of a 2 h information/education session to present the pen and learning its use. At the end of the session, patients completed a self-administered questionnaire regarding the meeting usefulness. Second phase: eight single-use prefilled Enbrel® Pen Myclic were provided. The number of patients included were 104 (rheumatoid arthritis 58, psoriatic arthritis 31, ankylosing spondylitis 15). Attendees showed a high satisfaction degree with the meeting. A high percentage of patients (74.4 - 95.1%) rated the items of the questionnaire as 'very much'. Patients reported > 95% adherence to etanercept autoinjection pen. The percentage of patients self-administering etanercept increased from 66 to 94% and the percentage of those attending primary care for injection decreased from 23 to 2%. It produced important cost savings, in our study represents > 22.000 euros/year. Pain at the injection site was significantly reduced with the use of autoinjection pen. Ninty seven (93%) patients considered that the use of the autoinjection pen was easier than the syringe and 94.2% chose the pen as their preferred delivery system. The autoinjection pen is an advantageous delivery option for etanercept. This study provides further evidence to support that the education strategy is a valid method for switching anti-TNF-α drugs from syringe to pen in patients with rheumatoid arthritis, psoriatic arthritis and ankylosing spondylitis.

  5. Genotype variation and genetic relationship among Escherichia coli from nursery pigs located in different pens in the same farm.

    PubMed

    Herrero-Fresno, Ana; Ahmed, Shahana; Hansen, Monica Hegstad; Denwood, Matthew; Zachariasen, Camilla; Olsen, John Elmerdahl

    2017-01-05

    So far, little is known about the genetic diversity and relatedness among Escherichia coli (E. coli) populations in the gut of swine. Information on this is required to improve modeling studies on antimicrobial resistance aiming to fight its occurrence and development. This work evaluated the genotype variation of E. coli isolated from swine fecal samples at the single pig and pen level, as well as between pens using repetitive extragenic palindromic (REP) PCR fingerprinting and pulsed field gel electrophoresis (PFGE). The genetic diversity of strains collected from media supplemented with ampicillin or tetracycline was also investigated. Besides, the genetic relationship of strains within each pen, between pens, as well as among strains within each group isolated from media with or without antibiotic, was assessed. REP-PCR patterns (N = 75) were generated for all the isolates (N = 720). Two profiles (REP_2 and REP_5) dominated, accounting for 23.7 and 23.3% of all isolates, respectively. At the pig and at the pen level, the number of different strains ranged from two to eight, and from 27 to 31, respectively, and multiple isolates from a single pen were found to be identical; however, in some of the pens, additional strains occurred at a lower frequency. E. coli isolates yielding different REP profiles were subjected to PFGE and led to 41 different genotypes which were also compared. Despite the presence of dominant strains, our results suggest a high genetic diversity of E. coli strains exist at the pen level and between pens. Selection with antibiotic seems to not affect the genetic diversity. The dominant REP profiles were the same found in a previous study in Denmark, which highlights that the same predominant strains are circulating in pigs of this country and might represent the archetypal E.coli commensal in pigs.

  6. Detecting long tandem duplications in genomic sequences.

    PubMed

    Audemard, Eric; Schiex, Thomas; Faraut, Thomas

    2012-05-08

    Detecting duplication segments within completely sequenced genomes provides valuable information to address genome evolution and in particular the important question of the emergence of novel functions. The usual approach to gene duplication detection, based on all-pairs protein gene comparisons, provides only a restricted view of duplication. In this paper, we introduce ReD Tandem, a software using a flow based chaining algorithm targeted at detecting tandem duplication arrays of moderate to longer length regions, with possibly locally weak similarities, directly at the DNA level. On the A. thaliana genome, using a reference set of tandem duplicated genes built using TAIR,(a) we show that ReD Tandem is able to predict a large fraction of recently duplicated genes (dS  <  1) and that it is also able to predict tandem duplications involving non coding elements such as pseudo-genes or RNA genes. ReD Tandem allows to identify large tandem duplications without any annotation, leading to agnostic identification of tandem duplications. This approach nicely complements the usual protein gene based which ignores duplications involving non coding regions. It is however inherently restricted to relatively recent duplications. By recovering otherwise ignored events, ReD Tandem gives a more comprehensive view of existing evolutionary processes and may also allow to improve existing annotations.

  7. Pen rearing and imprinting of fall Chinook salmon. Annual report 1989

    USGS Publications Warehouse

    Beeman, J.W.; Novotny, J.F.

    1990-01-01

    The goal of this project is to compare net-pen rearing methods to traditional hatchery methods of rearing upriver bright fall chinook salmon (Oncorhvnchus tshawvtscha). Fish were reared at several densities in net pens at three Columbia River backwater sites during 1984-1987, and in a barrier net at one site during 1984-1986; methods included both fed and unfed treatments. The purpose of this report is to summarize the results obtained from the unfed treatments and the current return of adults from all fed treatments and the barrier net. Zooplankton were the primary food item of unfed fish. Fish reared in net pens utilized insects colonizing the nets as an additional food source, whereas those reared in the barrier net did not. Growth and production of fish reared in the unfed treatments were low. Instantaneous growth rates of unfed fish were much lower than those of the fed treatments and hatchery controls except when zooplankton densities were high and chironomid larvae were important in the diet of unfed fish reared in pens. Only fish in the barrier net treatment resulted in consistent net gains in growth and production over the rearing periods. Adult returns of fish from all fed and unfed treatments are lower than those of control fish reared at the hatchery. Returns appear to be inversely related to rearing density. Even though adult returns are lower than those of traditional hatchery methods, a cost-benefit analysis, as return data becomes more complete, may prove these methods to be an economical means of expanding current hatchery production, particularly if "thinning" releases were used.

  8. A feature based comparison of pen and swipe based signature characteristics.

    PubMed

    Robertson, Joshua; Guest, Richard

    2015-10-01

    Dynamic Signature Verification (DSV) is a biometric modality that identifies anatomical and behavioral characteristics when an individual signs their name. Conventionally signature data has been captured using pen/tablet apparatus. However, the use of other devices such as the touch-screen tablets has expanded in recent years affording the possibility of assessing biometric interaction on this new technology. To explore the potential of employing DSV techniques when a user signs or swipes with their finger, we report a study to correlate pen and finger generated features. Investigating the stability and correlation between a set of characteristic features recorded in participant's signatures and touch-based swipe gestures, a statistical analysis was conducted to assess consistency between capture scenarios. The results indicate that there is a range of static and dynamic features such as the rate of jerk, size, duration and the distance the pen traveled that can lead to interoperability between these two systems for input methods for use within a potential biometric context. It can be concluded that this data indicates that a general principle is that the same underlying constructional mechanisms are evident. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. A microdestructive capillary electrophoresis method for the analysis of blue-pen-ink strokes on office paper.

    PubMed

    Calcerrada, Matías; González-Herráez, Miguel; Garcia-Ruiz, Carmen

    2015-06-26

    This manuscript describes the development of a capillary electrophoresis (CE) method for the detection of acid and basic dyes and its application to real samples, blue-pen-ink strokes on office paper. First, a capillary zone electrophoresis (CZE) method was developed for the separation of basic and acid dyes, by studying the separation medium (buffer nature, pH and relative amount of additive) and instrumental parameters (temperature, voltage and capillary dimensions). The method performance was evaluated in terms of selectivity, resolution (above 5 and 2 for acid dyes and basic dyes, respectively, except for two basic dye standards), LOD (lower than 0.4 mg/L) and precision as intraday and interday RSD values of peak migration times (lower than 0.6%). The developed method was then applied to 34 blue pens from different technologies (rollerball, ballpoint, markers) and with different ink composition (gel, water-based, oil-based). A microdestructive sample treatment using a scalpel to scratch 0.3mg of ink stroke was performed. The entire electropherogram profile allowed the visual discrimination between different types of ink and brands, being not necessary a statistical treatment. A 100% of discrimination was achieved between pen technologies, brands, and models, although non-reproducible zones in the electropherograms were found for blue gel pen samples. The two different batches of blue oil-based pens were also differentiated. Thus, this method provides a simple, microdestructive, and rapid analysis of different blue pen technologies which may complement the current analysis of questioned documents performed by forensic laboratories. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. 1. Historic American Buildings Survey, pen and ink sketch before ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Historic American Buildings Survey, pen and ink sketch before 1886 VIEW FROM THE SOUTH. - Governor Williams Coddington House, Marlborough Street (Parts in Rhode Island Historical Society), Newport, Newport County, RI

  11. Feedlot- and Pen-Level Prevalence of Enterohemorrhagic Escherichia coli in Feces of Commercial Feedlot Cattle in Two Major U.S. Cattle Feeding Areas.

    PubMed

    Cull, Charley A; Renter, David G; Dewsbury, Diana M; Noll, Lance W; Shridhar, Pragathi B; Ives, Samuel E; Nagaraja, Tiruvoor G; Cernicchiaro, Natalia

    2017-06-01

    The objective of this study was to determine feedlot- and pen-level fecal prevalence of seven enterohemorrhagic Escherichia coli (EHEC) belonging to serogroups (O26, O45, O103, O111, O121, O145, and O157, or EHEC-7) in feces of feedlot cattle in two feeding areas in the United States. Cattle pens from four commercial feedlots in each of the two major U.S. beef cattle areas were sampled. Up to 16 pen-floor fecal samples were collected from each of 4-6 pens per feedlot, monthly, for a total of three visits per feedlot, from June to August, 2014. Culture procedures including fecal enrichment in E. coli broth, immunomagnetic separation, and plating on selective media, followed by confirmation through polymerase chain reaction (PCR) testing, were conducted. Generalized linear mixed models were fitted to estimate feedlot-, pen-, and sample-level fecal prevalence of EHEC-7 and to evaluate associations between potential demographic and management risk factors with feedlot and within-pen prevalence of EHEC-7. All study feedlots and 31.0% of the study pens had at least one non-O157 EHEC-positive fecal sample, whereas 62.4% of pens tested positive for EHEC O157; sample-level prevalence estimates ranged from 0.0% for EHEC O121 to 18.7% for EHEC O157. Within-pen prevalence of EHEC O157 varied significantly by sampling month; similarly within-pen prevalence of non-O157 EHEC varied significantly by month and by the sex composition of the pen (heifer, steer, or mixed). Feedlot management factors, however, were not significantly associated with fecal prevalence of EHEC-7. Intraclass correlation coefficients for EHEC-7 models indicated that most of the variation occurred between pens, rather than within pens, or between feedlots. Hence, the potential combination of preharvest interventions and pen-level management strategies may have positive food safety impacts downstream along the beef chain.

  12. Kinetically Stabilized Axisymmetric Tandem Mirrors: Summary of Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Post, R F

    2005-02-08

    The path to practical fusion power through plasma confinement in magnetic fields, if it is solely based on the present front-runner, the tokamak, is clearly long, expensive, and arduous. The root causes for this situation lie in the effects of endemic plasma turbulence and in the complexity the tokamak's ''closed'' field geometry. The studies carried out in the investigations described in the attached reports are aimed at finding an approach that does not suffer from these problems. This goal is to be achieved by employing an axisymmetric ''open'' magnetic field geometry, i.e. one generated by a linear array of circularmore » magnet coils, and employing the magnetic mirror effect in accomplishing the plugging of end leakage. More specifically, the studies were aimed at utilizing the tandem-mirror concept in an axisymmetric configuration to achieve performance superior to the tokamak, and in a far simpler system, one for which the cost and development time could be much lower than that for the tokamak, as exemplified by ITER and its follow-ons. An important stimulus for investigating axisymmetric versions of the tandem mirror is the fact that, beginning from early days in fusion research there have been examples of axisymmetric mirror experiments where the plasma exhibited crossfield transport far below the turbulence-enhanced rates characteristic of tokamaks, in specific cases approaching the ''classical'' rate. From the standpoint of theory, axisymmetric mirror-based systems have special characteristics that help explain the low levels of turbulence that have been observed. Among these are the facts that there are no parallel currents in the equilibrium state, and that the drift surfaces of all of the trapped particles are closed surfaces, as shown early on by Teller and Northrop. In addition, in such systems it is possible to arrange that the radial boundary of the confined plasma terminates without contact with the chamber wall. This possibility reduces the

  13. Multiresidue analysis of 36 pesticides in soil using a modified quick, easy, cheap, effective, rugged, and safe method by liquid chromatography with tandem quadruple linear ion trap mass spectrometry.

    PubMed

    Feng, Xue; He, Zeying; Wang, Lu; Peng, Yi; Luo, Ming; Liu, Xiaowei

    2015-09-01

    A new method for simultaneous determination of 36 pesticides, including 15 organophosphorus, six carbamate, and some other pesticides in soil was developed by liquid chromatography with tandem quadruple linear ion trap mass spectrometry. The extraction and clean-up steps were optimized based on the quick, easy, cheap, effective, rugged, and safe method. The data were acquired in multiple reaction monitoring mode combined with enhanced product ion to increase confidence of the analytical results. Validation experiments were performed in soil samples. The average recoveries of pesticides at four spiking levels (1, 5, 50, and 100 μg/kg) ranged from 63 to 126% with relative standard deviation below 20%. The limits of detection of pesticides were 0.04-0.8 μg/kg, and the limits of quantification were 0.1-2.6 μg/kg. The correlation coefficients (r(2) ) were higher than 0.990 in the linearity range of 0.5-200 μg/L for most of the pesticides. The method allowed for the analysis of the target pesticides in the lower μg/kg concentration range. The optimized method was then applied to the test of real soil samples obtained from several areas in China, confirming the feasibility of the method. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Effect of marking pens on femtosecond laser-assisted flap creation.

    PubMed

    Ide, Takeshi; Kymionis, George D; Abbey, Ashkan M; Yoo, Sonia H; Culbertson, William W; O'Brien, Terrence P

    2009-06-01

    To compare the ease of the flap lift after central corneal marking with 2 types of marking pens after femtosecond laser-assisted flap creation in laser in situ keratomileusis. Bascom Palmer Eye Institute, University of Miami, Miami, Florida, USA. Porcine eyes were prepared for flap creation with a femtosecond laser (IntraLase). The eyes were assigned to 1 of 4 groups. After the femtosecond laser treatment, the difficulty of flap lifting the 4 groups was compared. Twelve porcine eyes, 3 in each group, were evaluated. In the 2 groups in which an oil-based pen was used, the corneal flap could not be lifted. In the 2 groups in which a water-based pen was used, the corneal flap was easily lifted. Oil-based ink may reduce the ability of the femtosecond laser to penetrate the cornea. The resultant corneal flap may require aggressive manipulation to be lifted. When used to mark the center of the cornea before flap creation, water-based ink provided greater ease of corneal flap lifting than oil-based ink. Because the marking is located over the center of the pupil, any alteration of the cornea in this area from aggressive flap lifting may result in substantial visual loss. Therefore, the use of an oil-based ink to mark the central cornea must be avoided to prevent traumatic irregularities of the flap stroma.

  15. A Prototype of Mathematical Treatment of Pen Pressure Data for Signature Verification.

    PubMed

    Li, Chi-Keung; Wong, Siu-Kay; Chim, Lai-Chu Joyce

    2018-01-01

    A prototype using simple mathematical treatment of the pen pressure data recorded by a digital pen movement recording device was derived. In this study, a total of 48 sets of signature and initial specimens were collected. Pearson's correlation coefficient was used to compare the data of the pen pressure patterns. From the 820 pair comparisons of the 48 sets of genuine signatures, a high degree of matching was found in which 95.4% (782 pairs) and 80% (656 pairs) had rPA > 0.7 and rPA > 0.8, respectively. In the comparison of the 23 forged signatures with their corresponding control signatures, 20 of them (89.2% of pairs) had rPA values < 0.6, showing a lower degree of matching when compared with the results of the genuine signatures. The prototype could be used as a complementary technique to improve the objectivity of signature examination and also has a good potential to be developed as a tool for automated signature identification. © 2017 American Academy of Forensic Sciences.

  16. 5. Contextual view of EPA Farm showing holding pens, facing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Contextual view of EPA Farm showing holding pens, facing west-southwest. - Nevada Test Site, Environmental Protection Agency Farm, Area 15, Yucca Flat, 10-2 Road near Circle Road, Mercury, Nye County, NV

  17. Gonococcal Resistance to β-Lactams and Tetracycline Involves Mutation in Loop 3 of the Porin Encoded at the penB Locus

    PubMed Central

    Gill, M. J.; Simjee, S.; Al-Hattawi, K.; Robertson, B. D.; Easmon, C. S. F.; Ison, C. A.

    1998-01-01

    penB is a chromosomal mutation that confers resistance to β-lactams and tetracyclines and reduced susceptibility to quinolones in Neisseria gonorrhoeae. It is linked to the porin gene (por) and requires the increased expression of an efflux pump due to mtr. Transformation of a susceptible gonococcus (strain H1) with chromosomal DNA from strain FA140 (penA mtr penB; porin serovar IB1) and conjugal transfer of a β-lactamase-expressing plasmid was used to produce isogenic strains for determination of equilibrium periplasmic penicillin concentrations by the method of Zimmermann and Rosselet (W. Zimmermann and A. Rosselet, Antimicrob. Agents Chemother. 12:368–372, 1977). In transformants with the Mtr and PenB phenotypes, equilibrium concentrations of penicillin were reduced. DNA sequence analysis of por from isogenic penB and penB+ transformants revealed 14 sequence differences; nine of these differences resulted in amino acid changes. Three amino acid changes were found in the putative gonococcal equivalent of the pore-constricting loop 3 of Escherichia coli OmpF. Two of these changes (Gly-101–Ala-102→Asp-Asp) result in an increased negative charge at this position in por loop 3. PCR products comprising the complete por gene from strain FA140 were transformed into strain H1-2 (penA mtr; porin serovar IB-3), with the resulting transformants having the antibiotic susceptibility phenotype associated with penB. penB-like mutations were found in loop 3 of clinical isolates of gonococci with chromosomally mediated resistance to penicillin. We conclude that penB is a mutation in loop 3 of por that reduces porin permeability to hydrophilic antibiotics and plays an important role in the development of chromosomally mediated resistance to penicillin and tetracycline in gonococci. PMID:9797206

  18. Stacking Multiple Ion Captures in The High Performance Antiproton Trap (HiPAT)

    NASA Technical Reports Server (NTRS)

    Martin, James J.; Lewis, Raymond A.; Sims, William H.; Chakrabarti, Suman; Pearson, Boise; Fant, Wallace E.

    2004-01-01

    The High performance Antiproton Trap (HiPAT) research project was initiated by the Marshall Space Flight Center's propulsion Research Center to examining the fundamental behavior of low energy antiprotons. Stored antiproton would ultimately be used for experimental demonstration of basic propulsive concepts. Matter-antimatter annihilation produces approximately 10(exp 8) MJ/g nearly 10 orders of magnitude more energy per unit mass than chemical based combustion, hence NASA's interest. To achieve containment, HiPAT utilizes a type of electromagnetic bottle know as a Penning trap positioned within an ultrahigh vacuum test section. Recently, the HiPAT hardware configuration has been enhanced to facilitate the capture of multiple normal matter ion burst. This endeavor is often referred to as "stacking" and used to increasing the number of captured particles. A prior normal matter experimental effort, successfully demonstrated the effectiveness of single burst capture. The stacking process is accomplished by manipulating the electric field generated by the confinement electrodes i.e. adjusting the well potential depth. These potential well values are initially configured to maximize the quantity of captured ions per burst; shallow wells with a depth of 100 volt or less (referenced to the incoming ion beam energy) are typically selected. Once captured, a cooling interval is required to reduce the energy of trapped particles below the lower extent of the "trap door" (or leading electrode) ion emitting potential. This is necessary such that a new burst of hot ions can be introduced while preventing those already inside from escaping. The cooling time is driven by a combination of mechanisms such as synchrotron radiation, background gas scattering, and resistive damping in a time scale on the order of minutes. A potential for reducing this hold period is to actively manipulate the electric field shape, using the power supply control system, to produce a deeper potential

  19. Human factors engineering and design validation for the redesigned follitropin alfa pen injection device.

    PubMed

    Mahony, Mary C; Patterson, Patricia; Hayward, Brooke; North, Robert; Green, Dawne

    2015-05-01

    To demonstrate, using human factors engineering (HFE), that a redesigned, pre-filled, ready-to-use, pre-asembled follitropin alfa pen can be used to administer prescribed follitropin alfa doses safely and accurately. A failure modes and effects analysis identified hazards and harms potentially caused by use errors; risk-control measures were implemented to ensure acceptable device use risk management. Participants were women with infertility, their significant others, and fertility nurse (FN) professionals. Preliminary testing included 'Instructions for Use' (IFU) and pre-validation studies. Validation studies used simulated injections in a representative use environment; participants received prior training on pen use. User performance in preliminary testing led to IFU revisions and a change to outer needle cap design to mitigate needle stick potential. In the first validation study (49 users, 343 simulated injections), in the FN group, one observed critical use error resulted in a device design modification and another in an IFU change. A second validation study tested the mitigation strategies; previously reported use errors were not repeated. Through an iterative process involving a series of studies, modifications were made to the pen design and IFU. Simulated-use testing demonstrated that the redesigned pen can be used to administer follitropin alfa effectively and safely.

  20. Pervasive liquid metal based direct writing electronics with roller-ball pen

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, Yi; Zhang, Qin; Liu, Jing, E-mail: jliu@mail.ipc.ac.cn

    A roller-ball pen enabled direct writing electronics via room temperature liquid metal ink was proposed. With the rolling to print mechanism, the metallic inks were smoothly written on flexible polymer substrate to form conductive tracks and electronic devices. The contact angle analyzer and scanning electron microscope were implemented to disclose several unique inner properties of the obtained electronics. An ever high writing resolution with line width and thickness as 200 μm and 80 μm, respectively was realized. Further, with the administration of external writing pressure, GaIn{sub 24.5} droplets embody increasing wettability on polymer which demonstrates the pervasive adaptability of themore » roller-ball pen electronics.« less

  1. Photophysical and photochemical effects of UV and VUV photo-oxidation and photolysis on PET and PEN

    NASA Astrophysics Data System (ADS)

    Morgan, Andrew

    Polyethylene Terephthalate (PET) is a widely used polymer in the bottling, packaging, and clothing industry. In recent years an increasing global demand for PET has taken place due to the Solar Disinfection (SODIS) process. SODIS is a method of sterilizing fresh water into drinkable water. The PET bottles are used in the process to contain the water during solar irradiation due to its highly transparent optical property. Alongside PET, polyethylene 2,6-napthalate (PEN) is used in bottling and flexible electronic applications. The surface of PEN would need to be modified to control the hydrophilicity and the interaction it exudes as a substrate. The UV light absorption properties of PET and PEN are of great importance for many applications, and thus needs to be studied along with its photochemical resistance. The optical and chemical nature of PET was studied as it was treated by UV photo-oxidation, photo-ozonation, and photolysis under atmospheric pressure. Another investigation was also used to study PEN and PET as they are treated by vacuum UV (VUV) photo-oxidation, VUV photolysis, and remote oxygen reactions. The extent of the photoreactions' effect into the depth of the polymers is examined as treatment conditions are changed. The different experimental methods established the rate of several competing photoreactions on PET and PEN during irradiance, and their effect on the optical quality of the polymers.

  2. On the inter-instrument and the inter-laboratory transferability of a tandem mass spectral reference library: 2. Optimization and characterization of the search algorithm.

    PubMed

    Oberacher, Herbert; Pavlic, Marion; Libiseller, Kathrin; Schubert, Birthe; Sulyok, Michael; Schuhmacher, Rainer; Csaszar, Edina; Köfeler, Harald C

    2009-04-01

    A sophisticated matching algorithm developed for highly efficient identity search within tandem mass spectral libraries is presented. For the optimization of the search procedure a collection of 410 tandem mass spectra corresponding to 22 compounds was used. The spectra were acquired in three different laboratories on four different instruments. The following types of tandem mass spectrometric instruments were used: quadrupole-quadrupole-time-of-flight (QqTOF), quadrupole-quadrupole-linear ion trap (QqLIT), quadrupole-quadrupole-quadrupole (QqQ), and linear ion trap-Fourier transform ion cyclotron resonance mass spectrometer (LIT-FTICR). The obtained spectra were matched to an established MS/MS-spectral library that contained 3759 MS/MS-spectra corresponding to 402 different reference compounds. All 22 test compounds were part of the library. A dynamic intensity cut-off, the search for neutral losses, and optimization of the formula used to calculate the match probability were shown to significantly enhance the performance of the presented library search approach. With the aid of these features the average number of correct assignments was increased to 98%. For statistical evaluation of the match reliability the set of fragment ion spectra was extended with 300 spectra corresponding to 100 compounds not included in the reference library. Performance was checked with the aid of receiver operating characteristic (ROC) curves. Using the magnitude of the match probability as well as the precursor ion mass as benchmarks to rate the obtained top hit, overall correct classification of a compound being included or not included in the mass spectrometric library, was obtained in more than 95% of cases clearly indicating a high predictive accuracy of the established matching procedure. Copyright (c) 2009 John Wiley & Sons, Ltd.

  3. Review of the High Performance Antiproton Trap (HiPAT) Experiment at the Marshall Space Flight Center

    NASA Technical Reports Server (NTRS)

    Pearson, J. B.; Sims, Herb; Martin, James; Chakrabarti, Suman; Lewis, Raymond; Fant, Wallace

    2003-01-01

    The significant energy density of matter-antimatter annihilation is attractive to the designers of future space propulsion systems, with the potential to offer a highly compact source of power. Many propulsion concepts exist that could take advantage of matter-antimatter reactions, and current antiproton production rates are sufficient to support basic proof-of-principle evaluation of technology associated with antimatter- derived propulsion. One enabling technology for such experiments is portable storage of low energy antiprotons, allowing antiprotons to be trapped, stored, and transported for use at an experimental facility. To address this need, the Marshall Space Flight Center's Propulsion Research Center is developing a storage system referred to as the High Performance Antiproton Trap (HiPAT) with a design goal of containing 10(exp 12) particles for up to 18 days. The HiPAT makes use of an electromagnetic system (Penning- Malmberg design) consisting of a 4 Telsa superconductor, high voltage electrode structure, radio frequency (RF) network, and ultra high vacuum system. To evaluate the system normal matter sources (both electron guns and ion sources) are used to generate charged particles. The electron beams ionize gas within the trapping region producing ions in situ, whereas the ion sources produce the particles external to the trapping region and required dynamic capture. A wide range of experiments has been performed examining factors such as ion storage lifetimes, effect of RF energy on storage lifetime, and ability to routinely perform dynamic ion capture. Current efforts have been focused on improving the FW rotating wall system to permit longer storage times and non-destructive diagnostics of stored ions. Typical particle detection is performed by extracting trapped ions from HiPAT and destructively colliding them with a micro-channel plate detector (providing number and energy information). This improved RF system has been used to detect various

  4. Short Tandem Repeat DNA Internet Database

    National Institute of Standards and Technology Data Gateway

    SRD 130 Short Tandem Repeat DNA Internet Database (Web, free access)   Short Tandem Repeat DNA Internet Database is intended to benefit research and application of short tandem repeat DNA markers for human identity testing. Facts and sequence information on each STR system, population data, commonly used multiplex STR systems, PCR primers and conditions, and a review of various technologies for analysis of STR alleles have been included.

  5. Second Generation Electronic Nicotine Delivery System Vape Pen Exposure Generalizes as a Smoking Cue.

    PubMed

    King, Andrea C; Smith, Lia J; McNamara, Patrick J; Cao, Dingcai

    2018-01-05

    Second generation electronic nicotine delivery systems (ENDS; also known as e-cigarettes, vaporizers or vape pens) are designed for a customized nicotine delivery experience and have less resemblance to regular cigarettes than first generation "cigalikes." The present study examined whether they generalize as a conditioned cue and evoke smoking urges or behavior in persons exposed to their use. Data were analyzed in N = 108 young adult smokers (≥5 cigarettes per week) randomized to either a traditional combustible cigarette smoking cue or a second generation ENDS vaping cue in a controlled laboratory setting. Cigarette and e-cigarette urge and desire were assessed pre- and post-cue exposure. Smoking behavior was also explored in a subsample undergoing a smoking latency phase after cue exposure (N = 26). The ENDS vape pen cue evoked both urge and desire for a regular cigarette to a similar extent as that produced by the combustible cigarette cue. Both cues produced similar time to initiate smoking during the smoking latency phase. The ENDS vape pen cue elicited smoking urge and desire regardless of ENDS use history, that is, across ENDS naїve, lifetime or current users. Inclusion of past ENDS or cigarette use as covariates did not significantly alter the results. These findings demonstrate that observation of vape pen ENDS use generalizes as a conditioned cue to produce smoking urge, desire, and behavior in young adult smokers. As the popularity of these devices may eventually overtake those of first generation ENDS cigalikes, exposure effects will be of increasing importance. This study shows that passive exposure to a second generation ENDS vape pen cue evoked smoking urge, desire, and behavior across a range of daily and non-daily young adult smokers. Smoking urge and desire increases after vape pen exposure were similar to those produced by exposure to a first generation ENDS cigalike and a combustible cigarette, a known potent cue. Given the increasing

  6. Mosquito vectors of West Nile virus during an epizootic outbreak in Puerto Rico.

    PubMed

    Barrera, R; MacKay, A; Amador, M; Vasquez, J; Smith, J; Díaz, A; Acevedo, V; Cabán, B; Hunsperger, E A; Muñoz-Jordán, J L

    2010-11-01

    The purpose of this investigation was to identify the mosquito (Diptera: Culicidae) vectors of West Nile virus (WNV; family Flaviviridae, genus Flavivirus) during an epizootic WNV outbreak in eastern Puerto Rico in 2007. In June 2006, 12 sentinel chicken pens with five chickens per pen were deployed in six types of habitats: herbaceous wetlands, mangrove forests, deciduous forests, evergreen forests, rural areas, and urban areas. Once WNV seroconversion in chickens was detected in June 2007, we began trapping mosquitoes using Centers for Disease Control and Prevention (CDC) miniature (light/CO2-baited) traps, CMT-20 collapsible mosquito (CO2- and ISCA SkinLure-baited) traps, and CDC gravid (hay infusion-baited) traps. We placed the CDC miniature traps both 2-4 m and >30 m from the chicken pens, the collapsible traps 2-4 m from the pens, and the gravid traps in backyards of houses with sentinel chicken pens and in a wetland adjacent to an urban area. We found numerous blood-engorged mosquitoes in the traps nearest to the sentinel chickens and reasoned that any such mosquitoes with a disseminated WNV infection likely served as vectors for the transmission of WNV to the sentinels. We used reverse transcriptase-polymerase chain reaction and isolation (C636) on pools of heads, thoraxes/ abdomens, and legs of collected blood-engorged mosquitoes to determine whether the mosquitoes carried WNV. We detected WNV-disseminated infections in and obtained WNV isolates from Culex nigripalpus Theo (minimum infection rate [MIR] 1.1-9.7/1,000), Culex bahamensis Dyar and Knab (MIR 1.8-6.0/1,000), and Aedes taeniorhynchus (Wied.) (MIR 0.34-0.36/1,000). WNV was also identified in and isolated from the pool of thoraxes and abdomens of Culex quinquefasciatus Say (4.17/1,000) and identified in one pool of thoraxes and abdomens of Culex habilitator Dyar and Knab (13.39/1,000). Accumulated evidence since 2002 suggests that WNV has not become endemic in Puerto Rico.

  7. A Distonic Radical-Ion for Detection of Traces of Adventitious Molecular Oxygen (O2) in Collision Gases Used in Tandem Mass Spectrometers

    NASA Astrophysics Data System (ADS)

    Jariwala, Freneil B.; Hibbs, John A.; Weisbecker, Carl S.; Ressler, John; Khade, Rahul L.; Zhang, Yong; Attygalle, Athula B.

    2014-09-01

    We describe a diagnostic ion that enables rapid semiquantitative evaluation of the degree of oxygen contamination in the collision gases used in tandem mass spectrometers. Upon collision-induced dissociation (CID), the m/z 359 positive ion generated from the analgesic etoricoxib undergoes a facile loss of a methyl sulfone radical [•SO2(CH3); 79-Da] to produce a distonic radical cation of m/z 280. The product-ion spectrum of this m/z 280 ion, recorded under low-energy activation on tandem-in-space QqQ or QqTof mass spectrometers using nitrogen from a generator as the collision gas, or tandem-in-time ion-trap (LCQ, LTQ) mass spectrometers using purified helium as the buffer gas, showed two unexpected peaks at m/z 312 and 295. This enigmatic m/z 312 ion, which bears a mass-to-charge ratio higher than that of the precursor ion, represented an addition of molecular oxygen (O2) to the precursor ion. The exceptional affinity of the m/z 280 radical cation towards oxygen was deployed to develop a method to determine the oxygen content in collision gases.

  8. Technical note: Mining data from on-farm electronic equipment to identify the time dairy cows spend away from the pen.

    PubMed

    Thompson, A J; Weary, D M; von Keyserlingk, M A G

    2017-05-01

    The electronic equipment used on farms can be creatively co-opted to collect data for which it was not originally designed. In the current study, we describe 2 novel algorithms that harvest data from electronic feeding equipment and data loggers used to record standing and lying behavior, to estimate the time that dairy cows spend away from their pen to be milked. Our 2 objectives were to (1) measure the ability of the first algorithm to estimate the time cows spend away from the pen as a group and (2) determine the capability of a second algorithm to estimate the time it takes for individual cows to return to their pen after being milked. To achieve these objectives, we conducted 2 separate experiments: first, to estimate group time away, the feeding behavior of 1 pen of 20 Holstein cows was monitored electronically for 1 mo; second, to measure individual latency to return to the pen, feeding and lying behavior of 12 healthy Holstein cows was monitored electronically from parturition to 21 d in milk. For both experiments, we monitored the time each individual cow exited the pen before each milking and when she returned to the pen after milking using video recordings. Estimates generated by our algorithms were then compared with the times captured from the video recordings. Our first algorithm provided reliable pen-based estimates for the minimum time cows spent away from the pen to be milked in the morning [coefficient of determination (R 2 ) = 0.92] and afternoon (R 2 = 0.96). The second algorithm was able to estimate of the time it took for individual cows to return to the pen after being milked in the morning (R 2 = 0.98), but less so in the afternoon (R 2 = 0.67). This study illustrates how data from electronic systems used to assess feeding and lying behavior can be mined to estimate novel measures. New work is now required to improve the estimates of our algorithm for individuals, for example by adding data from other electronic monitoring systems on the

  9. How to use pen and paper tasks to aid tremor diagnosis in the clinic

    PubMed Central

    Alty, Jane; Cosgrove, Jeremy; Thorpe, Deborah; Kempster, Peter

    2017-01-01

    When a patient presents with tremor, it can be useful to perform a few simple pen and paper tests. In this article, we explain how to maximise the value of handwriting and of drawing Archimedes spirals and straight lines as clinical assessments. These tasks take a matter of seconds to complete but provide a wealth of information that supplements the standard physical examination. They aid the diagnosis of a tremor disorder and can contribute to its longitudinal monitoring. Watching the patient’s upper limb while they write and draw may reveal abnormalities such as bradykinesia, dystonic posturing and distractibility. The finished script and drawings can then be evaluated for frequency, amplitude, direction and symmetry of oscillatory pen movements and for overall scale of penmanship. Essential, dystonic, functional and parkinsonian tremor each has a characteristic pattern of abnormality on these pen and paper tests. PMID:28844041

  10. The finer points of lying online: e-mail versus pen and paper.

    PubMed

    Naquin, Charles E; Kurtzberg, Terri R; Belkin, Liuba Y

    2010-03-01

    The authors present 3 experimental studies that build on moral disengagement theory by exploring lying in online environments. Findings indicate that, when e-mail is compared with pen and paper communication media (both of which are equal in terms of media richness, as both are text only), people are more willing to lie when communicating via e-mail than via pen and paper and feel more justified in doing so. The findings were consistent whether the task assured participants that their lie either would or would not be discovered by their counterparts. Implications for theory and practice are discussed. 2010 APA, all rights reserved

  11. Neon-hydrogen penning plasma laser in a helical hallow-cathode discharge

    NASA Astrophysics Data System (ADS)

    Pramatarov, P. M.; Stefanova, M. S.; Ganciu, M.; Karelin, A. V.; Yancharina, A. M.; Ivanova, J. P.; Yakovlenko, S. I.

    1991-07-01

    A Penning plasma laser (PPL) operating at the NeI 585.3 nm and NeI 1.15 μm lines in Ne-H2 mixture has been realized. Helical configuration of the electrodes was used. The dependence of the laser-pulse shape and output power on current pulse duration and amplitude values were investigated. Peak output powers of 1.5 W for the yellow line and 1.2 W for the IR line have been measured. The population inversion mechanism for the 585.3 nm line is discussed in the frames of a model for PPL. The main factor maintaining the population inversion on both lines is depopulation of the Ne(1 s 2) level by Penning reactions with H2.

  12. Neon-hydrogen Penning plasma laser in a helical hallow-cathode discharge

    NASA Astrophysics Data System (ADS)

    Pramatarov, P. M.; Stefanova, M. S.; Ivanova, J. P.; Ganciu, M.; Karelin, A. V.; Iakovlenko, S. I.; Iancharina, A. M.

    1991-07-01

    A Penning plasma laser (PPL) operating at the NeI 585.3 nm and NeI 1.15-micron lines in Ne-H2 mixture has been realized. Helical configuration of the electrodes was used. The dependence of the laser-pulse shape and output power on current pulse duration and amplitude values were investigated. Peak output powers of 1.5 W for the yellow line and 1.2 W for the IR line have been measured. The population inversion mechanism for the 585.3 nm line is discussed in the frames of a model for PPL. The main factor maintaining the population inversion on both lines is depopulation of the Ne(1S2) level by Penning reactions with H2.

  13. Gradual training of alpacas to the confinement of metabolism pens reduces stress when normal excretion behavior is accommodated.

    PubMed

    Lund, Kirrin E; Maloney, Shane K; Milton, John T B; Blache, Dominique

    2012-01-01

    Confinement in metabolism pens may provoke a stress response in alpacas that will reduce the welfare of the animal and jeopardize the validity of scientific results obtained in such pens. In this study, we tested a protocol designed to successfully train alpacas to be held in a specially designed metabolism pen so that the animals' confinement would not jeopardize their welfare. We hypothesized that the alpacas would show fewer behaviors associated with a response to stress as training gradually progressed, and that they would adapt to being in the confinement of the metabolism pen. The training protocol was successful at introducing alpacas to the metabolism pens, and it did reduce the incidence of behavioral responses to stress as the training progressed. The success of the training protocol may be attributed to the progressive nature of the training, the tailoring of the protocol to suit alpacas, and the use of positive reinforcement. This study demonstrated that both animal welfare and the validity of the scientific outcomes could be maximized by the gradual training of experimental animals, thereby minimizing the stress imposed on the animals during experimental procedures.

  14. A Digital Library for Education: The PEN-DOR Project.

    ERIC Educational Resources Information Center

    Fullerton, Karen; Greenberg, Jane; McClure, Maureen; Rasmussen, Edie; Stewart, Darin

    1999-01-01

    Describes Pen-DOR (Pennsylvania Education Network Digital Object Repository), a digital library designed to provide K-12 educators with access to multimedia resources and tools to create new lesson plans and modify existing ones via the World Wide Web. Discusses design problems of a distributed, object-oriented database architecture and describes…

  15. Comparison of Trapping Performance Between the Original BG-Sentinel® Trap and BG-Sentinel 2® Trap (1).

    PubMed

    Arimoto, Hanayo; Harwood, James F; Nunn, Peter J; Richardson, Alec G; Gordon, Scott; Obenauer, Peter J

    2015-12-01

    Recently, the BG-Sentinel® trap (BGS) trap has been reconfigured for increased durability during harsh field conditions. We evaluated the attractiveness of this redesigned trap, BG-Sentinel 2® (BGS2), and its novel granular lure cartridge system relative to the original trap and lure. Granular lures containing different combinations of lactic acid, ammonia, hexanoic acid, and octenol were also evaluated. Lure cartridges with all components except octenol trapped significantly more Aedes albopictus than lures containing octenol. This new granular lure combination and original BG-Lure® system were paired with BGS and BGS2 traps to compare relative attractiveness of the lures and the traps. All evaluations were conducted under field conditions in a suburban neighborhood in northeastern Florida from July to October 2014. Overall, the average numbers of Ae. albopictus collected by BGS or BGS2 were similar regardless of the lure type (i.e., mesh bag versus granules) (P  =  0.56). The functionality and durability of both trap models are discussed.

  16. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR LIGHT PEN OPERATION AND VERIFICATION OF SCANNED BAR CODES (UA-D-33.0)

    EPA Science Inventory

    The purpose of this SOP is to define the steps needed to operate the light pens, and verify the values produced by light pens used in the Arizona NHEXAS project and the "Border" study. Keywords: data; equipment; light pens.

    The National Human Exposure Assessment Survey (NHEXAS)...

  17. Neisseria cinerea with High Ceftriaxone MIC Is a Source of Ceftriaxone and Cefixime Resistance-Mediating penA Sequences in Neisseria gonorrhoeae.

    PubMed

    Igawa, Gene; Yamagishi, Yuka; Lee, Ken-Ichi; Dorin, Misato; Shimuta, Ken; Suematsu, Hiroyuki; Nakayama, Shu-Ichi; Mikamo, Hiroshige; Unemo, Magnus; Ohnishi, Makoto

    2018-03-01

    Mosaic penA alleles have caused most of the cephalosporin resistance in Neisseria gonorrhoeae , but their evolution is mostly unknown. The penA gene from Neisseria cinerea strain AM1601 (ceftriaxone MIC, 1.0 μg/ml) caused ceftriaxone resistance (MIC, 1 μg/ml) in a ceftriaxone-susceptible gonococcal strain. The 3'-terminal half of AM1601 penA was almost identical to that of the ceftriaxone-resistant gonococcal GU140106 and FC428 strains. N. cinerea can serve as a reservoir of ceftriaxone resistance-mediating penA sequences that can be transferred to gonococci. Copyright © 2018 American Society for Microbiology.

  18. Optical trapping

    PubMed Central

    Neuman, Keir C.; Block, Steven M.

    2006-01-01

    Since their invention just over 20 years ago, optical traps have emerged as a powerful tool with broad-reaching applications in biology and physics. Capabilities have evolved from simple manipulation to the application of calibrated forces on—and the measurement of nanometer-level displacements of—optically trapped objects. We review progress in the development of optical trapping apparatus, including instrument design considerations, position detection schemes and calibration techniques, with an emphasis on recent advances. We conclude with a brief summary of innovative optical trapping configurations and applications. PMID:16878180

  19. Tracking Color Shift in Ballpoint Pen Ink Using Photoshop Assisted Spectroscopy: A Nondestructive Technique Developed to Rehouse a Nobel Laureate's Manuscript

    PubMed Central

    Wright, Kristi; Herro, Holly

    2016-01-01

    Many historically and culturally significant documents from the mid-to-late twentieth century were written in ballpoint pen inks, which contain light-sensitive dyes that present problems for collection custodians and paper conservators. The conservation staff at the National Library of Medicine (NLM), National Institutes of Health, conducted a multiphase project on the chemistry and aging of ballpoint pen ink that culminated in the development of a new method to detect aging of ballpoint pen ink while examining a variety of storage environments. NLM staff determined that ballpoint pen ink color shift can be detected noninvasively using image editing software. Instructions are provided on how to detect color shift in digitized materials using a technique developed specifically for this project—Photoshop Assisted Spectroscopy.1 The study results offer collection custodians storage options for historic documents containing ballpoint pen ink. PMID:27587904

  20. A pen-based system to support pre-operative data collection within an anaesthesia department.

    PubMed Central

    Sanz, M. F.; Gómez, E. J.; Trueba, I.; Cano, P.; Arredondo, M. T.; del Pozo, F.

    1993-01-01

    This paper describes the design and implementation of a pen-based computer system for remote preoperative data collection. The system is envisaged to be used by anaesthesia staff at different hospital scenarios where pre-operative data are generated. Pen-based technology offers important advantages in terms of portability and human-computer interaction, as direct manipulation interfaces by direct pointing, and "notebook user interfaces metaphors". Being the human factors analysis and user interface design a vital stage to achieve the appropriate user acceptability, a methodology that integrates the "usability" evaluation from the earlier development stages was used. Additionally, the selection of a pen-based computer system as a portable device to be used by health care personnel allows to evaluate the appropriateness of this new technology for remote data collection within the hospital environment. The work presented is currently being realised under the Research Project "TANIT: Telematics in Anaesthesia and Intensive Care", within the "A.I.M.--Telematics in Health CARE" European Research Program. PMID:8130488

  1. 50 CFR 697.19 - Trap limits and trap tag requirements for vessels fishing with lobster traps.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... vessels fishing with lobster traps. 697.19 Section 697.19 Wildlife and Fisheries FISHERY CONSERVATION AND... requirements for vessels fishing with lobster traps. (a) Trap limits for vessels fishing or authorized to fish... management area designation certificate or valid limited access American lobster permit specifying one or...

  2. 50 CFR 697.19 - Trap limits and trap tag requirements for vessels fishing with lobster traps.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... vessels fishing with lobster traps. 697.19 Section 697.19 Wildlife and Fisheries FISHERY CONSERVATION AND... requirements for vessels fishing with lobster traps. (a) Trap limits for vessels fishing or authorized to fish... management area designation certificate or valid limited access American lobster permit specifying one or...

  3. Electromyographic comparison of forearm muscle movements for fine skin suturing between an enlarged pen needle holder and a webster needle holder.

    PubMed

    Ohata, Erika; Matsuo, Kiyoshi; Ban, Ryokuya; Shiba, Masato; Yasunaga, Yoshichika

    2013-01-01

    For surgical suturing, a Webster needle holder uses wrist supinating with supinator and extrinsic muscles, whereas a pen needle holder uses finger twisting with intrinsic and extrinsic muscles. Because the latter is better suited to microsurgery, which requires fine suturing with less forearm muscle movement, we have recently adopted an enlarged pen needle holder scaled from a micro needle holder for fine skin suturing. In this study, we assessed whether the enlarged pen needle holder reduced forearm muscle movement during fine skin suturing as compared with the Webster needle holder. A fine skin-suturing task was performed using pen holding with the enlarged micro needle holder or scissor holding with the Webster needle holder by 9 experienced and 6 inexperienced microsurgeons. The task lasted for 60 seconds and was randomly performed 3 times for each method. Forearm flexor and extensor muscular activities were evaluated by surface electromyography. The enlarged pen needle holder method required significantly less forearm muscle movement for experienced microsurgeons despite it being their first time using the instrument. There was no significant difference between 2 methods for inexperienced microsurgeons. Experienced microsurgeons conserved forearm muscle movement by finger twisting in fine skin suturing with the enlarged pen needle holder. Inexperienced microsurgeons may benefit from the enlarged pen needle holder, even for fine skin suturing, to develop their internal acquisition model of the dynamics of finger twisting.

  4. Tandem Organic Light-Emitting Diodes.

    PubMed

    Fung, Man-Keung; Li, Yan-Qing; Liao, Liang-Sheng

    2016-12-01

    A tandem organic light-emitting diode (OLED) is an organic optoelectronic device that has two or more electroluminescence (EL) units connected electrically in series with unique intermediate connectors within the device. Researchers have studied this new OLED architecture with growing interest and have found that the current efficiency of a tandem OLED containing N EL units (N > 1) should be N times that of a conventional OLED containing only a single EL unit. Therefore, this new architecture is potentially useful for constructing high-efficiency, high-luminance, and long-lifetime OLED displays and organic solid-state lighting sources. In a tandem OLED, the intermediate connector plays a crucial role in determining the effectiveness of the stacked EL units. The interfaces in the connector control the inner charge generation and charge injection into the adjacent EL units. Meanwhile, the transparency and the thickness of the connector affect the light output of the device. Therefore, the intermediate connector should be made to meet both the electrical and optical requirements for achieving optimal performance. Here, recent advances in the research of the tandem OLEDs is discussed, with the main focus on material selection and interface studies in the intermediate connectors, as well as the optical design of the tandem OLEDs. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. 50 CFR 697.19 - Trap limits and trap tag requirements for vessels fishing with lobster traps.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... vessels fishing with lobster traps. 697.19 Section 697.19 Wildlife and Fisheries FISHERY CONSERVATION AND... requirements for vessels fishing with lobster traps. (a) Trap limits for vessels fishing or authorized to fish in any Nearshore Management Area. (1) Through August 31, 2003, vessels fishing in or issued a...

  6. Temperature and body weight affect fouling of pig pens.

    PubMed

    Aarnink, A J A; Schrama, J W; Heetkamp, M J W; Stefanowska, J; Huynh, T T T

    2006-08-01

    Fouling of the solid lying area in pig housing is undesirable for reasons of animal welfare, animal health, environmental pollution, and labor costs. In this study the influence of temperature on the excreting and lying behavior of growing-finishing pigs of different BW (25, 45, 65, 85, or 105 kg) was studied. Ten groups of 5 pigs were placed in partially slatted pens (60% solid concrete, 40% metal-slatted) in climate respiration chambers. After an adaptation period, temperatures were raised daily for 9 d. Results showed that above certain inflection temperatures (IT; mean 22.6 degrees C, SE = 0.78) the number of excretions (relative to the total number of excretions) on the solid floor increased with temperature (mean increase 9.7%/ degrees C, SE = 1.41). Below the IT, the number of excretions on the solid floor was low and not influenced by temperature (mean 13.2%, SE = 3.5). On average, the IT for excretion on the solid floor decreased with increasing BW, from approximately 25 degrees C at 25 kg to 20 degrees C at 100 kg of BW (P < 0.05). Increasing temperature also affected the pattern and postural lying. The temperature at which a maximum number of pigs lay on the slatted floor (i.e., the IT for lying) decreased from approximately 27 degrees C at 25 kg to 23 degrees C at 100 kg of BW (P < 0.001). At increasing temperatures, pigs lay more on their sides and less against other pigs (P < 0.001). Temperature affects lying and excreting behavior of growing-finishing pigs in partially slatted pens. Above certain IT, pen fouling increases linearly with temperature. Inflection temperatures decrease at increasing BW.

  7. Development of a highly-sensitive Penning ionization electron spectrometer using the magnetic bottle effect

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ota, Masahiro; Ishiguro, Yuki; Nakajima, Yutaro

    2016-02-01

    This paper reports on a highly-sensitive retarding-type electron spectrometer for a continuous source of electrons, in which the electron collection efficiency is increased by utilizing the magnetic bottle effect. This study demonstrates an application to Penning ionization electron spectroscopy using collisional ionization with metastable He*(2{sup 3}S) atoms. Technical details and performances of the instrument are presented. This spectrometer can be used for studies of functional molecules and assemblies, and exterior electron densities are expected to be selectively observed by the Penning ionization.

  8. Rainfall Driven Sorting of Soils and Manure in Beef Feedlot Pens, Implications for Steroid Hormone Transport

    NASA Astrophysics Data System (ADS)

    Bryson, R.; Harter, T.

    2009-12-01

    Previous research has documented elevated estrogenic and androgenic activity in surface waters receiving cattle feedlot effluent, while current research shows that significant concentrations of hydrophobic steroid hormones are transported in the solid phase of feedlot pen surface runoff. Accumulated manure in beef feedlot pens includes organic matter ranging from colloidal particles to partially digested feed, forming a complex soil-manure conglomerate at the pen surface. We hypothesized that the transport of solid phase particles in rainfall runoff on beef feedlots would be influenced but not limited by shield layer development. Soils and manure at a beef feedlot were evaluated before and after rainfall-runoff events to determine changes in soil composition and structure. Runoff samples were also collected during an hour of runoff and analyzed for suspended solids. Results indicate that rainfall actively sorts the soil and manure components through raindrop impact, depression storage and runoff. However, transport of solid phase constituents was found to be elevated throughout the hydrograph. This suggests that the surface shield layer conceptualization applied to other soils should be modified before application to the soil-manure conglomerate found in beef feedlot pens.

  9. Tandem mass spectrometric analysis of cyclophosphamide, ifosfamide and their metabolites.

    PubMed

    Liu, Zhongfa; Chan, Kenneth K; Wang, Jeffrey J

    2005-01-01

    A detailed multi-stage (MSn) fragmentation study of cyclophosphamide (CP), ifosfamide (IF) and their major metabolites, using an ion-trap mass spectrometer and a Q-TOF mass spectrometer, was performed with the aid of specifically deuterium-labeled analogs. The analytes showed good responses in positive-ion electrospray mass spectrometry as [MH]+ ions. Tandem mass spectra revealed a wealth of structurally specific ions, allowing characterization of the fragmentation pathways of these analytes. The major fragmentation pathways of the protonated CP and IF are elimination of ethylene from C5 and C6 of 1,3,2-oxazaphosphorine-2-oxide via a McLafferty rearrangement, and cleavage of the P-N bond. However, their activated 4-OOH and 4-OH metabolites primarily underwent hydrogen peroxide elimination and dehydration, respectively, followed by fragmentation pathways similar to those of CP and IF. These results should prove useful in structural elucidation of future analogs of CP and IF, and/or of their metabolites. Copyright (c) 2005 John Wiley & Sons, Ltd.

  10. Dose accuracy of a durable insulin pen with memory function, before and after simulated lifetime use and under stress conditions.

    PubMed

    Xue, Ligang; Mikkelsen, Kristian Handberg

    2013-03-01

    The objective of this study was to assess the dose accuracy of NovoPen® 5 in delivering low, medium and high doses of insulin before and after simulated lifetime use. A secondary objective was to evaluate the durability of the pen and its memory function under various stress conditions designed to simulate conditions that may be encountered in everyday use of an insulin pen. All testing was conducted according to International Organization for Standardization guideline 11608-1, 2000 for pen injectors. Dose accuracy was measured for the delivery of 1 unit (U) (10 mg), 30 U (300 mg) and 60 U (600 mg) test medium in standard, cool and hot conditions and before and after simulated lifetime use. Dose accuracy was also tested after preconditioning in dry heat storage; cold storage; damp cyclical heat; shock, bump and vibration; free fall and after electrostatic charge and radiated field test. Memory function was tested under all temperature and physical conditions. NovoPen 5 maintained dosing accuracy and memory function at minimum, medium and maximum doses in standard, cool and hot conditions, stress tests and simulated lifetime use. The pens remained intact and retained dosing accuracy and a working memory function at all doses after exposure to variations in temperature and after physical challenge. NovoPen 5 was accurate at all doses tested and under various functionality tests. Its durable design ensured that the dose accuracy and memory function were retained under conditions of stress likely to be encountered in everyday use.

  11. High voltage series connected tandem junction solar battery

    DOEpatents

    Hanak, Joseph J.

    1982-01-01

    A high voltage series connected tandem junction solar battery which comprises a plurality of strips of tandem junction solar cells of hydrogenated amorphous silicon having one optical path and electrically interconnected by a tunnel junction. The layers of hydrogenated amorphous silicon, arranged in a tandem configuration, can have the same bandgap or differing bandgaps. The tandem junction strip solar cells are series connected to produce a solar battery of any desired voltage.

  12. Coaxial ion trap mass spectrometer: concentric toroidal and quadrupolar trapping regions.

    PubMed

    Peng, Ying; Hansen, Brett J; Quist, Hannah; Zhang, Zhiping; Wang, Miao; Hawkins, Aaron R; Austin, Daniel E

    2011-07-15

    We present the design and results for a new radio-frequency ion trap mass analyzer, the coaxial ion trap, in which both toroidal and quadrupolar trapping regions are created simultaneously. The device is composed of two parallel ceramic plates, the facing surfaces of which are lithographically patterned with concentric metal rings and covered with a thin film of germanium. Experiments demonstrate that ions can be trapped in either region, transferred from the toroidal to the quadrupolar region, and mass-selectively ejected from the quadrupolar region to a detector. Ions trapped in the toroidal region can be transferred to the quadrupole region using an applied ac signal in the radial direction, although it appears that the mechanism of this transfer does not involve resonance with the ion secular frequency, and the process is not mass selective. Ions in the quadrupole trapping region are mass analyzed using dipole resonant ejection. Multiple transfer steps and mass analysis scans are possible on a single population of ions, as from a single ionization/trapping event. The device demonstrates better mass resolving power than the radially ejecting halo ion trap and better sensitivity than the planar quadrupole ion trap.

  13. Does pen help? A real-world outcomes study of switching from vial to disposable pen among insulin glargine-treated patients with type 2 diabetes mellitus.

    PubMed

    Xie, Lin; Zhou, Steve; Wei, Wenhui; Gill, Jasvinder; Pan, Chunshen; Baser, Onur

    2013-03-01

    The study was designed to evaluate real-world data on clinical and economic outcome differences between patients with type 2 diabetes mellitus (T2DM) who use insulin glargine with vial-and-syringe delivery and those who switch to pen administration. This retrospective study analyzed medical and pharmacy claims information from the national managed-care IMPACT(®) database (Ingenix Inc., Salt Lake City, UT). Adults with T2DM treated with insulin glargine were evaluated. Clinical and economic outcomes over 1 year were compared between individuals who had converted from administering glargine via vial-and-syringe to the SoloSTAR(®) (sanofi-aventis U.S., Bridgewater, NJ) pen (Switchers) and patients who continued to use vial-and-syringe administration (Continuers). Patients from each cohort were matched using propensity score matching for a comparison sample. In total, 3,893 eligible patients were identified (665 Switchers and 3,228 Continuers), with a matched cohort with 603 patients in each group. Baseline characteristics were similar between groups. One-year treatment persistence was significantly higher with Switchers versus Continuers (65.3% vs. 49.8%; P<0.0001). Medication possession ratio was also significantly higher among Switchers (0.79 vs. 0.76; P=0.0173). Insulin use and glycemic control were similar between groups. Healthcare utilization and total costs were also similar between groups. Higher prescription costs among Switchers were offset by lower overall and diabetes-related outpatient and inpatient costs. Switching from insulin glargine vial-and-syringe administration to pen delivery resulted in improved treatment adherence and persistence, with comparable clinical and economic outcomes.

  14. Novel product ions of 2-aminoanilide and benzimidazole Ag(I) complexes using electrospray ionization with multi-stage tandem mass spectrometry.

    PubMed

    Johnson, Byron S; Burinsky, David J; Burova, Svetlana A; Davis, Roman; Fitzgerald, Russ N; Matsuoka, Richard T

    2012-05-15

    The 2-aminoaniline scaffold is of significant value to the pharmaceutical industry and is embedded in a number of pharmacophores including 2-aminoanilides and benzimidazoles. A novel application of coordination ion spray mass spectrometry (CIS-MS) for interrogating the silver ion (Ag(+)) complexes of a homologous series of these compounds using multi-stage tandem mass spectrometry is described. Unlike the ubiquitous alkali metal ion complexes, Ag(+) complexes of 2-aminoanilides and benzimidazoles were found to yield [M - H](+) ions in significant abundance via gas-phase elimination of the metal hydride (AgH) resulting in unique product ion cascades. Sample introduction was by liquid chromatography with mass spectrometry analysis performed on a hybrid linear ion trap/orbitrap instrument capable of high-resolution measurements. Rigorous structural characterization by multi-stage tandem mass spectrometry using [M +  H](+), [M - H](-) and [M - H](+) precursor ions derived from ESI and CIS experiments was performed for the homologous series of 2-aminoanilide and benzimidazole compounds. A full tabular comparison of structural information resulting from these product ion cascades was produced. Multi-stage tandem mass spectrometry of [M - H](+) ions resulting from Ag(+) complexes of 2-aminoanilides and benzimidazoles in CIS-MS experiments produced unique product ion cascades that exhibited complementary structural information to that obtained from tandem mass spectrometry of [M  +  H](+) and [M - H](-) ions by electrospray ionization (ESI). These observations may be broadly applicable to other compounds that are observed to form Ag(+) complexes and eliminate AgH. Copyright © 2012 John Wiley & Sons, Ltd.

  15. Inactivation of Gram-negative and Gram-positive bacteria in red cell concentrates using INACTINE PEN110 chemistry.

    PubMed

    Zavizion, B; Serebryanik, D; Chapman, J; Alford, B; Purmal, A

    2004-10-01

    The risk of transfusion-transmitted bacterial infections as a result of the presence of bacteria in blood is one of the major concerns in transfusion medicine. The purpose of this study was to investigate whether bacteria inoculated into red blood cell concentrates can be inactivated by the INACTINE PEN110 pathogen-reduction process. Four bacterial species were chosen for the study: anaerobic Gram-positive Clostridium perfringens and Propionibacterium acnes, known to be transfusion-transmitted; and two Gram-negative species, Acinetobacter johnsonii and Acinetobacter lwoffii, recently reported to be a common cause of transfusion-associated infections in Europe. Identical units of leucoreduced red cell concentrates were inoculated with A. johnsonii, A. lwoffii, C. perfringens, or P. acnes. The 4 degrees C control units were put on storage immediately after receiving the spike. The test units were subjected to PEN110 treatment and then stored. The bacterial titre in all units was monitored during a 6-week storage period. The PEN110 inactivation of all tested bacterial strains was time- and titre-dependent. For A. johnsonii and A. lwoffii, no viable bacteria were detected in the units spiked with up to 10(4) colony-forming units (CFU)/ml and treated with PEN110. For red cell units spiked with 10(4)-10(5) CFU/ml of C. perfringens and P. acnes, no viable bacteria were detected in the units treated with PEN110. In control units, there was a gradual decrease in A. johnsonii, A. lwoffii and C. perfringens titres during cold storage, while P. acnes titres remained stable. The PEN110 pathogen-reduction process was demonstrated to inactivate high titres of A. johnsonii, A. lwoffii, C. perfringens and P. acnes in red cell concentrates.

  16. Stable Trapping of Multielectron Helium Bubbles in a Paul Trap

    NASA Astrophysics Data System (ADS)

    Joseph, E. M.; Vadakkumbatt, V.; Pal, A.; Ghosh, A.

    2017-06-01

    In a recent experiment, we have used a linear Paul trap to store and study multielectron bubbles (MEBs) in liquid helium. MEBs have a charge-to-mass ratio (between 10^{-4} and 10^{-2} C/kg) which is several orders of magnitude smaller than ions (between 10^6 and 10^8 C/kg) studied in traditional ion traps. In addition, MEBs experience significant drag force while moving through the liquid. As a result, the experimental parameters for stable trapping of MEBs, such as magnitude and frequency of the applied electric fields, are very different from those used in typical ion trap experiments. The purpose of this paper is to model the motion of MEBs inside a linear Paul trap in liquid helium, determine the range of working parameters of the trap, and compare the results with experiments.

  17. Preferences of lame cows for type of surface and level of social contact in hospital pens.

    PubMed

    Jensen, M B; Herskin, M S; Thomsen, P T; Forkman, B; Houe, H

    2015-07-01

    To investigate preferences of lame cows for flooring and level of social contact, 37 lame, lactating dairy cows (diagnosed with sole ulcer or white line disease) were housed individually for 6 d in experimental hospital pens, where they could choose between 2 equally sized areas (6m × 4.5m) with either deep-bedded sand or a rubber surface. On both surfaces, cows could choose between 2 equally sized areas either near or away from heifers in a neighboring group pen. Cows spent more time lying on the deep-bedded sand than on the rubber surface (870 vs. 71min/d), whereas they spent less time upright (standing or walking) on the sand than on the rubber surface (180 vs. 319min/d). In addition, cows spent less time self-grooming on the sand than on the rubber surface (2.2 vs. 4.7% of time spent upright). With regard to level of social contact, cows spent more time near the neighboring heifers than away from them; this was true both while lying (565 vs. 374min/d) and upright (276 vs. 223min/d). Self-grooming was seen significantly more near neighboring heifers than away from them (4.8 vs. 3.3% of time spent upright). When lying, cows more often positioned themselves in areas of the pen where they could maintain visual contact with neighboring heifers. Lame cows with sole ulcers or white line disease preferred deep-bedded sand for lying, and preferred to perform self-grooming while on the rubber surface. Similarly, they preferred to lie and to perform self-grooming while positioned near animals in a neighboring pen. These results suggest that provision of a deep-bedded lying area in hospital pens is important to the welfare of lame cows. We found no evidence of isolation-seeking behavior in animals with these diagnoses (and no systemic symptoms) while they were kept in individual hospital pens. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  18. Electromyographic Comparison of Forearm Muscle Movements for Fine Skin Suturing Between an Enlarged Pen Needle Holder and a Webster Needle Holder

    PubMed Central

    Ohata, Erika; Matsuo, Kiyoshi; Ban, Ryokuya; Shiba, Masato; Yasunaga, Yoshichika

    2013-01-01

    Background: For surgical suturing, a Webster needle holder uses wrist supinating with supinator and extrinsic muscles, whereas a pen needle holder uses finger twisting with intrinsic and extrinsic muscles. Because the latter is better suited to microsurgery, which requires fine suturing with less forearm muscle movement, we have recently adopted an enlarged pen needle holder scaled from a micro needle holder for fine skin suturing. In this study, we assessed whether the enlarged pen needle holder reduced forearm muscle movement during fine skin suturing as compared with the Webster needle holder. Methods: A fine skin-suturing task was performed using pen holding with the enlarged micro needle holder or scissor holding with the Webster needle holder by 9 experienced and 6 inexperienced microsurgeons. The task lasted for 60 seconds and was randomly performed 3 times for each method. Forearm flexor and extensor muscular activities were evaluated by surface electromyography. Results: The enlarged pen needle holder method required significantly less forearm muscle movement for experienced microsurgeons despite it being their first time using the instrument. There was no significant difference between 2 methods for inexperienced microsurgeons. Conclusions: Experienced microsurgeons conserved forearm muscle movement by finger twisting in fine skin suturing with the enlarged pen needle holder. Inexperienced microsurgeons may benefit from the enlarged pen needle holder, even for fine skin suturing, to develop their internal acquisition model of the dynamics of finger twisting. PMID:23691259

  19. Multiplexed biomimetic lipid membranes on graphene by dip-pen nanolithography

    PubMed Central

    Hirtz, Michael; Oikonomou, Antonios; Georgiou, Thanasis; Fuchs, Harald; Vijayaraghavan, Aravind

    2013-01-01

    The application of graphene in sensor devices depends on the ability to appropriately functionalize the pristine graphene. Here we show the direct writing of tailored phospholipid membranes on graphene using dip-pen nanolithography. Phospholipids exhibit higher mobility on graphene compared with the commonly used silicon dioxide substrate, leading to well-spread uniform membranes. Dip-pen nanolithography allows for multiplexed assembly of phospholipid membranes of different functionalities in close proximity to each other. The membranes are stable in aqueous environments and we observe electronic doping of graphene by charged phospholipids. On the basis of these results, we propose phospholipid membranes as a route for non-covalent immobilization of various functional groups on graphene for applications in biosensing and biocatalysis. As a proof of principle, we demonstrate the specific binding of streptavidin to biotin-functionalized membranes. The combination of atomic force microscopy and binding experiments yields a consistent model for the layer organization within phospholipid stacks on graphene. PMID:24107937

  20. COLD TRAPS

    DOEpatents

    Thompson, W.I.

    1958-09-30

    A cold trap is presented for removing a condensable component from a gas mixture by cooling. It consists of a shell, the exterior surface of which is chilled by a refrigerant, and conductive fins welded inside the shell to condense the gas, and distribute the condensate evenly throughout the length of the trap, so that the trap may function until it becomes completely filled with the condensed solid. The contents may then be removed as either a gas or as a liquid by heating the trap. This device has particuinr use as a means for removing uranium hexafluoride from the gaseous diffusion separation process during equipment breakdown and repair periods.

  1. The Compensatory Effectiveness of the Quicktionary Reading Pen II on the Reading Comprehension of Students with Learning Disabilities

    ERIC Educational Resources Information Center

    Higgins, Eleanor L.; Raskind, Marshall H.

    2005-01-01

    The study investigated the compensatory effectiveness of the Quicktionary Reading Pen II (the Reading Pen), a portable device with miniaturized optical character recognition and speech synthesis capabilities. Thirty participants with reading disabilities aged 10-18 were trained on the operation of the technology and given two weeks to practice…

  2. Capillary trap column with strong cation-exchange monolith for automated shotgun proteome analysis.

    PubMed

    Wang, Fangjun; Dong, Jing; Jiang, Xiaogang; Ye, Mingliang; Zou, Hanfa

    2007-09-01

    A 150 microm internal diameter capillary monolithic column with a strong cation-exchange stationary phase was prepared by direct in situ polymerization of ethylene glycol methacrylate phosphate and bisacrylamide in a trinary porogenic solvent consisting dimethylsulfoxide, dodecanol, and N,N'-dimethylformamide. This phosphate monolithic column exhibits higher dynamic binding capacity, faster kinetic adsorption of peptides, and more than 10 times higher permeability than the column packed with commercially available strong cation-exchange particles. It was applied as a trap column in a nanoflow liquid chromatography-tandem mass spectrometry system for automated sample injection and online multidimensional separation. It was observed that the sample could be loaded at a flow rate as high as 40 microL/min with a back pressure of approximately 1300 psi and without compromising the separation efficiency. Because of its good orthogonality to the reversed phase separation mechanism, the phosphate monolithic trap column was coupled with a reversed-phase column for online multidimensional separation of 19 microg of the tryptic digest of yeast proteins. A total of 1522 distinct proteins were identified from 5608 unique peptides (total of 54,780 peptides) at the false positive rate only 0.46%.

  3. Systemic swings in end-Permian environments from Siberian Traps carbon and sulfur outgassing

    NASA Astrophysics Data System (ADS)

    Black, B. A.; Neely, R.; Lamarque, J. F.; Elkins-Tanton, L. T.; Kiehl, J. T.; Shields, C. A.; Mills, M. J.; Bardeen, C.

    2017-12-01

    U-Pb geochronology has revealed that Siberian Traps flood basalt magmatism coincided with the 252 Ma end-Permian mass extinction. Most environmental consequences of magmatism follow directly or indirectly from the release of sulfur and some combination of magmatic and metamorphic carbon to the atmosphere (exceptions include ozone depletion from halogen emissions, release of toxic metals, and enhanced weathering of fresh volcanic rocks). However, the critical combinations of forcing and stress that trigger global mass extinction remain unknown. In particular, the combined and competing effects of sulfur and carbon outgassing on Earth systems remain to be quantified. Here we present results from global climate model simulations of flood basalt outgassing that account for sulfur chemistry and aerosol microphysics. We consider the effects of sulfur and carbon in isolation and in tandem, and find that carbon and sulfur emissions combine to generate swings in climate, ocean circulation, and hydrology. Our simulations provide a self-consistent framework to quantitatively explain observed features of the end-Permian including surface warming, fluctuating ocean oxygenation, intense weathering, and carbon cycle perturbation, unifying observed changes in climate and geochemical cycles with feedbacks initiated by Siberian Traps magmatism.

  4. Trapping of ultracold polar molecules with a thin-wire electrostatic trap.

    PubMed

    Kleinert, J; Haimberger, C; Zabawa, P J; Bigelow, N P

    2007-10-05

    We describe the realization of a dc electric-field trap for ultracold polar molecules, the thin-wire electrostatic trap (TWIST). The thin wires that form the electrodes of the TWIST allow us to superimpose the trap onto a magneto-optical trap (MOT). In our experiment, ultracold polar NaCs molecules in their electronic ground state are created in the MOT via photoassociation, achieving a continuous accumulation in the TWIST of molecules in low-field seeking states. Initial measurements show that the TWIST trap lifetime is limited only by the background pressure in the chamber.

  5. 47 CFR 69.129 - Signalling for tandem switching.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 3 2011-10-01 2011-10-01 false Signalling for tandem switching. 69.129 Section... (CONTINUED) ACCESS CHARGES Computation of Charges § 69.129 Signalling for tandem switching. A charge that is... provision of signalling for tandem switching. [59 FR 32930, June 27, 1994] ...

  6. 47 CFR 69.129 - Signalling for tandem switching.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Signalling for tandem switching. 69.129 Section... (CONTINUED) ACCESS CHARGES Computation of Charges § 69.129 Signalling for tandem switching. A charge that is... provision of signalling for tandem switching. [59 FR 32930, June 27, 1994] ...

  7. 47 CFR 69.129 - Signalling for tandem switching.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 3 2013-10-01 2013-10-01 false Signalling for tandem switching. 69.129 Section... (CONTINUED) ACCESS CHARGES Computation of Charges § 69.129 Signalling for tandem switching. A charge that is... provision of signalling for tandem switching. [59 FR 32930, June 27, 1994] ...

  8. 47 CFR 69.129 - Signalling for tandem switching.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 3 2012-10-01 2012-10-01 false Signalling for tandem switching. 69.129 Section... (CONTINUED) ACCESS CHARGES Computation of Charges § 69.129 Signalling for tandem switching. A charge that is... provision of signalling for tandem switching. [59 FR 32930, June 27, 1994] ...

  9. Comparative evaluation of the efficiency of the BG-Sentinel trap, CDC light trap and Mosquito-oviposition trap for the surveillance of vector mosquitoes.

    PubMed

    Li, Yiji; Su, Xinghua; Zhou, Guofa; Zhang, Hong; Puthiyakunnon, Santhosh; Shuai, Shufen; Cai, Songwu; Gu, Jinbao; Zhou, Xiaohong; Yan, Guiyun; Chen, Xiao-Guang

    2016-08-12

    The surveillance of vector mosquitoes is important for the control of mosquito-borne diseases. To identify a suitable surveillance tool for the adult dengue vector Aedes albopictus, the efficacy of the BG-Sentinel trap, CDC light trap and Mosquito-oviposition trap (MOT) on the capture of vector mosquitoes were comparatively evaluated in this study. The capture efficiencies of the BG-Sentinel trap, CDC light trap and Mosquito-oviposition trap for common vector mosquitoes were tested in a laboratory setting, through the release-recapture method, and at two field sites of Guangzhou, China from June 2013 to May 2014. The captured mosquitoes were counted, species identified and compared among the three traps on the basis of species. In the release-recapture experiments in a laboratory setting, the BG-Sentinel trap caught significantly more Aedes albopictus and Culex quinquefasciatus than the CDC light trap and Mosquito-ovitrap, except for Anopheles sinensis. The BG-Sentinel trap had a higher efficacy in capturing female rather than male Ae. albopictus and Cx. quinquefasciatus, but the capture in CDC light traps displayed no significant differences. In the field trial, BG-Sentinel traps collected more Aedes albopictus than CDC light traps and MOTs collected in both urban and suburban areas. The BG-Sentinel trap was more sensitive for monitoring the population density of Aedes albopictus than the CDC light trap and MOT during the peak months of the year 2013. However, on an average, CDC light traps captured significantly more Cx. quinquefasciatus than BG-Sentinel traps. The population dynamics of Cx. quinquefasciatus displayed a significant seasonal variation, with the lowest numbers in the middle of the year. This study indicates that the BG-Sentinel trap is more effective than the commonly used CDC light trap and MOT in sampling adult Aedes albopictus and Culex quinquefasciatus. We recommend its use in the surveillance of dengue vector mosquitoes in China.

  10. Simultaneous determination of triprolidine and pseudoephedrine in human plasma by liquid chromatography-ion trap mass spectrometry.

    PubMed

    Shakya, Ashok K; Arafat, Tawfiq A; Abuawwad, Ahmad N; Melhim, Munther; Al-Ghani, Jafar; Yacoub, Mahmoud J

    2009-12-15

    A highly efficient, selective and specific method for simultaneous quantitation of triprolidine and pseudoephedrine in human plasma by liquid chromatography-ion trap-tandem mass spectrometry coupled with electro spray ionization (LC-ESI-ion trap-tandem MS) has been validated and successfully applied to a clinical pharmacokinetic study. Both targeted compounds together with the internal standard (gabapentin) were extracted from the plasma by direct protein precipitation. Chromatographic separation was achieved on a C(18) ACE((R)) column (50.0mmx2.1mm, 5mum, Advance Chromatography Technologies, Aberdeen, UK), using an isocratic mobile phase, consisting of water, methanol and formic acid (55:45:0.5, v/v/v), at a flow-rate of 0.3mL/min. The transition monitored (positive mode) was m/z 279.1-->m/z 208.1 for triprolidine, m/z 165.9-->m/z 148.0 for pseudoephedrine and m/z 172.0-->m/z 154.0 for gabapentin (IS). This method had a chromatographic run time of 5.0min and a linear calibration curves ranged from 0.2 to 20.0ng/mL for triprolidine and 5.0-500.0ng/mL for pseudoephedrine. The within- and between-batch accuracy and precision (expressed as coefficient of variation, %C.V.) evaluated at four quality control levels were within 94.3-106.3% and 1.0-9.6% respectively. The mean recoveries of triprolidine, pseudoephedrine and gabapentin were 93.6, 76.3 and 82.0% respectively. Stability of triprolidine and pseudoephedrine was assessed under different storage conditions. The validated method was successfully employed for the bioequivalence study of triprolidine and pseudoephedrine formulation in twenty six volunteers under fasting conditions.

  11. Review on pen-and-paper-based observational methods for assessing ergonomic risk factors of computer work.

    PubMed

    Rahman, Mohd Nasrull Abdol; Mohamad, Siti Shafika

    2017-01-01

    Computer works are associated with Musculoskeletal Disorders (MSDs). There are several methods have been developed to assess computer work risk factor related to MSDs. This review aims to give an overview of current techniques available for pen-and-paper-based observational methods in assessing ergonomic risk factors of computer work. We searched an electronic database for materials from 1992 until 2015. The selected methods were focused on computer work, pen-and-paper observational methods, office risk factors and musculoskeletal disorders. This review was developed to assess the risk factors, reliability and validity of pen-and-paper observational method associated with computer work. Two evaluators independently carried out this review. Seven observational methods used to assess exposure to office risk factor for work-related musculoskeletal disorders were identified. The risk factors involved in current techniques of pen and paper based observational tools were postures, office components, force and repetition. From the seven methods, only five methods had been tested for reliability. They were proven to be reliable and were rated as moderate to good. For the validity testing, from seven methods only four methods were tested and the results are moderate. Many observational tools already exist, but no single tool appears to cover all of the risk factors including working posture, office component, force, repetition and office environment at office workstations and computer work. Although the most important factor in developing tool is proper validation of exposure assessment techniques, the existing observational method did not test reliability and validity. Futhermore, this review could provide the researchers with ways on how to improve the pen-and-paper-based observational method for assessing ergonomic risk factors of computer work.

  12. Mechanism of force mode dip-pen nanolithography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Haijun, E-mail: yanghaijun@sinap.ac.cn, E-mail: swguo@sjtu.edu.cn, E-mail: wanghuabin@cigit.ac.cn; Interfacial Water Division and Key Laboratory of Interfacial Physics and Technology, Shanghai Institute of Applied Physics, CAS, Shanghai 201800; Xie, Hui

    In this work, the underlying mechanism of the force mode dip-pen nanolithography (FMDPN) is investigated in depth by analyzing force curves, tapping mode deflection signals, and “Z-scan” voltage variations during the FMDPN. The operation parameters including the relative “trigger threshold” and “surface delay” parameters are vital to control the loading force and dwell time for ink deposition during FMDPN. A model is also developed to simulate the interactions between the atomic force microscope tip and soft substrate during FMDPN, and verified by its good performance in fitting our experimental data.

  13. Nematode-Trapping Fungi.

    PubMed

    Jiang, Xiangzhi; Xiang, Meichun; Liu, Xingzhong

    2017-01-01

    Nematode-trapping fungi are a unique and intriguing group of carnivorous microorganisms that can trap and digest nematodes by means of specialized trapping structures. They can develop diverse trapping devices, such as adhesive hyphae, adhesive knobs, adhesive networks, constricting rings, and nonconstricting rings. Nematode-trapping fungi have been found in all regions of the world, from the tropics to Antarctica, from terrestrial to aquatic ecosystems. They play an important ecological role in regulating nematode dynamics in soil. Molecular phylogenetic studies have shown that the majority of nematode-trapping fungi belong to a monophyletic group in the order Orbiliales (Ascomycota). Nematode-trapping fungi serve as an excellent model system for understanding fungal evolution and interaction between fungi and nematodes. With the development of molecular techniques and genome sequencing, their evolutionary origins and divergence, and the mechanisms underlying fungus-nematode interactions have been well studied. In recent decades, an increasing concern about the environmental hazards of using chemical nematicides has led to the application of these biological control agents as a rapidly developing component of crop protection.

  14. [Effects of large bio-manipulation fish pen on community structure of crustacean zooplankton in Meiliang Bay of Taihu Lake].

    PubMed

    Ke, Zhi-Xin; Xie, Ping; Guo, Long-Gen; Xu, Jun; Zhou, Qiong

    2012-08-01

    In 2005, a large bio-manipulation pen with the stock of silver carp and bighead carp was built to control the cyanobacterial bloom in Meiliang Bay of Taihu Lake. This paper investigated the seasonal variation of the community structure of crustacean zooplankton and the water quality within and outside the pen. There were no significant differences in the environmental parameters and phytoplankton biomass within and outside the pen. The species composition and seasonal dynamics of crustacean zooplankton within and outside the pen were similar, but the biomass of crustacean zooplankton was greatly suppressed by silver carp and bighead carp. The total crustacean zooplankton biomass and cladocerans biomass were significantly lower in the pen (P < 0.05). In general, silver carp and bighead carp exerted more pressure on cladoceran species than on copepod species. A distinct seasonal succession of crustacean zooplankton was observed in the Bay. Many crustacean species were only dominated in given seasons. Large-sized crustacean (mainly Daphnia sp. and Cyclops vicnus) dominated in winter and spring, while small-sized species (mainly Bosmina sp., Ceriodaphnia cornuta, and Limnoithona sinensis) dominated in summer and autumn. Canonical correspondence analysis showed that water transparency, temperature, and phytoplankton biomass were the most important factors affecting the seasonal succession of the crustacean.

  15. DC Potentials Applied to an End-cap Electrode of a 3-D Ion Trap for Enhanced MSn Functionality

    PubMed Central

    Prentice, Boone M.; Xu, Wei; Ouyang, Zheng; McLuckey, Scott A.

    2010-01-01

    The effects of the application of various DC magnitudes and polarities to an end-cap of a 3-D quadrupole ion trap throughout a mass spectrometry experiment were investigated. Application of a monopolar DC field was achieved by applying a DC potential to the exit end-cap electrode, while maintaining the entrance end-cap electrode at ground potential. Control over the monopolar DC magnitude and polarity during time periods associated with ion accumulation, mass analysis, ion isolation, ion/ion reaction, and ion activation can have various desirable effects. Included amongst these are increased ion capture efficiency, increased ion ejection efficiency during mass analysis, effective isolation of ions using lower AC resonance ejection amplitudes, improved temporal control of the overlap of oppositely charged ion populations, and the performance of “broad-band” collision induced dissociation (CID). These results suggest general means to improve the performance of the 3-D ion trap in a variety of mass spectrometry and tandem mass spectrometry experiments. PMID:21927573

  16. Double-trap measurement of the proton magnetic moment at 0.3 parts per billion precision.

    PubMed

    Schneider, Georg; Mooser, Andreas; Bohman, Matthew; Schön, Natalie; Harrington, James; Higuchi, Takashi; Nagahama, Hiroki; Sellner, Stefan; Smorra, Christian; Blaum, Klaus; Matsuda, Yasuyuki; Quint, Wolfgang; Walz, Jochen; Ulmer, Stefan

    2017-11-24

    Precise knowledge of the fundamental properties of the proton is essential for our understanding of atomic structure as well as for precise tests of fundamental symmetries. We report on a direct high-precision measurement of the magnetic moment μ p of the proton in units of the nuclear magneton μ N The result, μ p = 2.79284734462 (±0.00000000082) μ N , has a fractional precision of 0.3 parts per billion, improves the previous best measurement by a factor of 11, and is consistent with the currently accepted value. This was achieved with the use of an optimized double-Penning trap technique. Provided a similar measurement of the antiproton magnetic moment can be performed, this result will enable a test of the fundamental symmetry between matter and antimatter in the baryonic sector at the 10 -10 level. Copyright © 2017, American Association for the Advancement of Science.

  17. Speech understanding in noise with the Roger Pen, Naida CI Q70 processor, and integrated Roger 17 receiver in a multi-talker network.

    PubMed

    De Ceulaer, Geert; Bestel, Julie; Mülder, Hans E; Goldbeck, Felix; de Varebeke, Sebastien Pierre Janssens; Govaerts, Paul J

    2016-05-01

    Roger is a digital adaptive multi-channel remote microphone technology that wirelessly transmits a speaker's voice directly to a hearing instrument or cochlear implant sound processor. Frequency hopping between channels, in combination with repeated broadcast, avoids interference issues that have limited earlier generation FM systems. This study evaluated the benefit of the Roger Pen transmitter microphone in a multiple talker network (MTN) for cochlear implant users in a simulated noisy conversation setting. Twelve post-lingually deafened adult Advanced Bionics CII/HiRes 90K recipients were recruited. Subjects used a Naida CI Q70 processor with integrated Roger 17 receiver. The test environment simulated four people having a meal in a noisy restaurant, one the CI user (listener), and three companions (talkers) talking non-simultaneously in a diffuse field of multi-talker babble. Speech reception thresholds (SRTs) were determined without the Roger Pen, with one Roger Pen, and with three Roger Pens in an MTN. Using three Roger Pens in an MTN improved the SRT by 14.8 dB over using no Roger Pen, and by 13.1 dB over using a single Roger Pen (p < 0.0001). The Roger Pen in an MTN provided statistically and clinically significant improvement in speech perception in noise for Advanced Bionics cochlear implant recipients. The integrated Roger 17 receiver made it easy for users of the Naida CI Q70 processor to take advantage of the Roger system. The listening advantage and ease of use should encourage more clinicians to recommend and fit Roger in adult cochlear implant patients.

  18. Experimental Methods for Trapping Ions Using Microfabricated Surface Ion Traps

    PubMed Central

    Hong, Seokjun; Lee, Minjae; Kwon, Yeong-Dae; Cho, Dong-il "Dan"; Kim, Taehyun

    2017-01-01

    Ions trapped in a quadrupole Paul trap have been considered one of the strong physical candidates to implement quantum information processing. This is due to their long coherence time and their capability to manipulate and detect individual quantum bits (qubits). In more recent years, microfabricated surface ion traps have received more attention for large-scale integrated qubit platforms. This paper presents a microfabrication methodology for ion traps using micro-electro-mechanical system (MEMS) technology, including the fabrication method for a 14 µm-thick dielectric layer and metal overhang structures atop the dielectric layer. In addition, an experimental procedure for trapping ytterbium (Yb) ions of isotope 174 (174Yb+) using 369.5 nm, 399 nm, and 935 nm diode lasers is described. These methodologies and procedures involve many scientific and engineering disciplines, and this paper first presents the detailed experimental procedures. The methods discussed in this paper can easily be extended to the trapping of Yb ions of isotope 171 (171Yb+) and to the manipulation of qubits. PMID:28872137

  19. Particle-in-cell simulations of anomalous transport in a Penning discharge

    NASA Astrophysics Data System (ADS)

    Carlsson, Johan; Kaganovich, Igor; Powis, Andrew; Raitses, Yevgeny; Romadanov, Ivan; Smolyakov, Andrei

    2018-06-01

    Electrostatic particle-in-cell simulations of a Penning discharge are performed in order to investigate azimuthally asymmetric, spoke-like structures previously observed in experiments. Two-dimensional simulations show that for Penning-discharge conditions, a persistent nonlinear spoke-like structure forms readily and rotates in the direction of E × B and electron diamagnetic drifts. The azimuthal velocity is within about a factor of 2 of the ion acoustic speed. The spoke frequency follows the experimentally observed scaling with ion mass, which indicates the importance of ion inertia in spoke formation. The spoke provides enhanced (anomalous) radial electron transport, and the effective cross-field conductivity is several times larger than the classical (collisional) value. The level of anomalous current obtained in the simulations is in good agreement with the experimental data. The rotating spoke channels most of the radial current, observable by an edge probe as short pulses.

  20. Characterization of the Electron Energy Distribution Function in a Penning Discharge

    NASA Astrophysics Data System (ADS)

    Skoutnev, Valentin; Dourbal, Paul; Raitses, Yevgeny

    2017-10-01

    Slow and fast sweeping Langmuir probe diagnostics were implemented to measure the electron energy distribution function (EEDF) in a cross-field Penning discharge undergoing rotating spoke phenomenon. The EEDF was measured using the Druyvesteyn method. Rotating spoke occurs in a variety of ExB devices and is characterized primarily by azimuthal light, density, and potential fluctuations on the order of a few kHz, but is theoretically still not well understood. Characterization of a time-resolved EEDF of the spoke would be important for understanding physical mechanisms responsible for the spoke and its effects on Penning discharges, Hall thrusters, sputtering magnetrons, and other ExB devices. In this work, preliminary results of measurements of the EEDF using slow and fast Langmuir probes that sweep below and above the fundamental spoke frequency will be discussed. This work was supported by the Air Force Office of Scientific Research (AFOSR).

  1. Cost minimization analysis of different growth hormone pen devices based on time-and-motion simulations.

    PubMed

    Nickman, Nancy A; Haak, Sandra W; Kim, Jaewhan

    2010-04-08

    Numerous pen devices are available to administer recombinant Human Growth Hormone (rhGH), and both patients and health plans have varying issues to consider when selecting a particular product and device for daily use. Therefore, the present study utilized multi-dimensional product analysis to assess potential time involvement, required weekly administration steps, and utilization costs relative to daily rhGH administration. Study objectives were to conduct 1) Time-and-Motion (TM) simulations in a randomized block design that allowed time and steps comparisons related to rhGH preparation, administration and storage, and 2) a Cost Minimization Analysis (CMA) relative to opportunity and supply costs. Nurses naïve to rhGH administration and devices were recruited to evaluate four rhGH pen devices (2 in liquid form, 2 requiring reconstitution) via TM simulations. Five videotaped and timed trials for each product were evaluated based on: 1) Learning (initial use instructions), 2) Preparation (arrange device for use), 3) Administration (actual simulation manikin injection), and 4) Storage (maintain product viability between doses), in addition to assessment of steps required for weekly use. The CMA applied micro-costing techniques related to opportunity costs for caregivers (categorized as wages), non-drug medical supplies, and drug product costs. Norditropin(R) NordiFlex and Norditropin(R) NordiPen (NNF and NNP, Novo Nordisk, Inc., Bagsvaerd, Denmark) took less weekly Total Time (p < 0.05) to use than either of the comparator products, Genotropin(R) Pen (GTP, Pfizer, Inc, New York, New York) or HumatroPen(R) (HTP, Eli Lilly and Company, Indianapolis, Indiana). Time savings were directly related to differences in new package Preparation times (NNF (1.35 minutes), NNP (2.48 minutes) GTP (4.11 minutes), HTP (8.64 minutes), p < 0.05)). Administration and Storage times were not statistically different. NNF (15.8 minutes) and NNP (16.2 minutes) also took less time to Learn

  2. Characteristics of Handwriting of People With Cerebellar Ataxia: Three-Dimensional Movement Analysis of the Pen Tip, Finger, and Wrist.

    PubMed

    Fujisawa, Yuhki; Okajima, Yasutomo

    2015-11-01

    There are several functional tests for evaluating manual performance; however, quantitative manual tests for ataxia, especially those for evaluating handwriting, are limited. This study aimed to investigate the characteristics of cerebellar ataxia by analyzing handwriting, with a special emphasis on correlation between the movement of the pen tip and the movement of the finger or wrist. This was an observational study. Eleven people who were right-handed and had cerebellar ataxia and 17 people to serve as controls were recruited. The Scale for the Assessment and Rating of Ataxia was used to grade the severity of ataxia. Handwriting movements of both hands were analyzed. The time required for writing a character, the variability of individual handwriting, and the correlation between the movement of the pen tip and the movement of the finger or wrist were evaluated for participants with ataxia and control participants. The writing time was longer and the velocity profile and shape of the track of movement of the pen tip were more variable in participants with ataxia than in control participants. For participants with ataxia, the direction of movement of the pen tip deviated more from that of the finger or wrist, and the shape of the track of movement of the pen tip differed more from that of the finger or wrist. The severity of upper extremity ataxia measured with the Scale for the Assessment and Rating of Ataxia was mostly correlated with the variability parameters. Furthermore, it was correlated with the directional deviation of the trajectory of movement of the pen tip from that of the finger and with increased dissimilarity of the shapes of the tracks. The results may have been influenced by the scale and parameters used to measure movement. Ataxic handwriting with increased movement noise is characterized by irregular pen tip movements unconstrained by the finger or wrist. The severity of ataxia is correlated with these unconstrained movements. © 2015 American

  3. Application of micro-attenuated total reflectance Fourier transform infrared spectroscopy to ink examination in signatures written with ballpoint pen on questioned documents.

    PubMed

    Nam, Yun Sik; Park, Jin Sook; Lee, Yeonhee; Lee, Kang-Bong

    2014-05-01

    Questioned documents examined in a forensic laboratory sometimes contain signatures written with ballpoint pen inks; these signatures were examined to assess the feasibility of micro-attenuated total reflectance (ATR) Fourier transform infrared (FTIR) spectroscopy as a forensic tool. Micro-ATR FTIR spectra for signatures written with 63 ballpoint pens available commercially in Korea were obtained and used to construct an FTIR spectral database. A library-searching program was utilized to identify the manufacturer, blend, and model of each black ballpoint pen ink based upon their FTIR peak intensities, positions, and patterns in the spectral database. This FTIR technique was also successfully used in determining the sequence of homogeneous line intersections from the crossing lines of two ballpoint pen signatures. We have demonstrated with a set of sample documents that micro-ATR FTIR is a viable nondestructive analytical method that can be used to identify the origin of the ballpoint pen ink used to mark signatures. © 2014 American Academy of Forensic Sciences.

  4. Half-Unit Insulin Pens: Disease Management in Patients With Diabetes Who Are Sensitive to Insulin.

    PubMed

    Klonoff, David C; Nayberg, Irina; Stauder, Udo; Oualali, Hamid; Domenger, Catherine

    2017-05-01

    Insulin pens represent a significant technological advancement in diabetes management. While the vast majority have been designed with 1U-dosing increments, improved accuracy and precision facilitated by half-unit increments may be particularly significant in specific patients who are sensitive to insulin. These include patients with low insulin requirements and in those requiring more precise dose adjustments, such as the pediatric patient population. This review summarized functional characteristics of insulin half-unit pens (HUPs) and their effect on user experience. The literature search was restricted to articles published in English between January 1, 2000, and January 1, 2015. A total of 17 publications met the set criteria and were included in the review. Overall, studies outlined characteristics for 4 insulin HUPs. Based on their functionality, the pens were generally similar and all met the ISO 11608-1 criteria for accuracy. However, some had specific advantageous features in terms of size, weight, design, dialing torque, and injection force. Although limited, the currently available user preference studies in children and adolescents with diabetes and their carers suggest that the selection of an HUP is likely to be influenced by a combination of factors such as these, in addition to the prescribed insulin and dosing regimen. Insulin HUPs are likely to be a key diabetes management tool for patients who are sensitive to insulin; specific pen features may further advance diabetes management in these populations.

  5. Initial pen and field assessment of baits to use in oral rabies vaccination of Formosan ferret-badgers in response to the re-emergence of rabies in Taiwan

    PubMed Central

    Wallace, Ryan M.; Lai, Yuching; Doty, Jeffrey B.; Chen, Chen-Chih; Vora, Neil M.; Blanton, Jesse D.; Chang, Susan S.; Pei, Kurtis J. C.

    2018-01-01

    Background Taiwan had been considered rabies free since 1961, until a newly established wildlife disease surveillance program identified rabies virus transmission within the Formosan ferret-badger (Melogale moschata subaurantiaca) in 2013. Ferret-badgers occur throughout southern China and Southeast Asia, but their ecological niche is not well described. Methodology/Principle findings As an initial feasibility assessment for potential rabies control measures, field camera trapping and pen assessment of 6 oral rabies vaccine (ORV) baits were conducted in Taiwan in 2013. 46 camera nights were recorded; 6 Formosan ferret-badgers and 14 non-target mammals were sighted. No baits were consumed by ferret-badgers and 8 were consumed by non-target mammals. Penned ferret-badgers ingested 5 of the 18 offered baits. When pen and field trials were combined, and analyzed for palatability, ferret-badgers consumed 1 of 9 marshmallow baits (11.1%), 1 of 21 fishmeal baits (4.8%), 0 of 3 liver baits, and 3 of 3 fruit-flavored baits. It took an average of 261 minutes before ferret-badgers made oral contact with the non-fruit flavored baits, and 34 minutes for first contact with the fruit-based bait. Overall, ferret-badgers sought out the fruit baits 8 times faster, spent a greater proportion of time eating fruit baits, and were 7.5 times more likely to have ruptured the vaccine container of the fruit-based bait. Conclusions/Significance Ferret-badgers are now recognized as rabies reservoir species in China and Taiwan, through two independent ‘dog to ferret-badger’ host-shift events. Species of ferret-badgers can be found throughout Indochina, where they may be an unrecognized rabies reservoir. Findings from this initial study underscore the need for further captive and field investigations of fruit-based attractants or baits developed for small meso-carnivores. Non-target mammals’ competition for baits, ants, bait design, and dense tropical landscape represent potential

  6. Initial pen and field assessment of baits to use in oral rabies vaccination of Formosan ferret-badgers in response to the re-emergence of rabies in Taiwan.

    PubMed

    Wallace, Ryan M; Lai, Yuching; Doty, Jeffrey B; Chen, Chen-Chih; Vora, Neil M; Blanton, Jesse D; Chang, Susan S; Cleaton, Julie M; Pei, Kurtis J C

    2018-01-01

    Taiwan had been considered rabies free since 1961, until a newly established wildlife disease surveillance program identified rabies virus transmission within the Formosan ferret-badger (Melogale moschata subaurantiaca) in 2013. Ferret-badgers occur throughout southern China and Southeast Asia, but their ecological niche is not well described. As an initial feasibility assessment for potential rabies control measures, field camera trapping and pen assessment of 6 oral rabies vaccine (ORV) baits were conducted in Taiwan in 2013. 46 camera nights were recorded; 6 Formosan ferret-badgers and 14 non-target mammals were sighted. No baits were consumed by ferret-badgers and 8 were consumed by non-target mammals. Penned ferret-badgers ingested 5 of the 18 offered baits. When pen and field trials were combined, and analyzed for palatability, ferret-badgers consumed 1 of 9 marshmallow baits (11.1%), 1 of 21 fishmeal baits (4.8%), 0 of 3 liver baits, and 3 of 3 fruit-flavored baits. It took an average of 261 minutes before ferret-badgers made oral contact with the non-fruit flavored baits, and 34 minutes for first contact with the fruit-based bait. Overall, ferret-badgers sought out the fruit baits 8 times faster, spent a greater proportion of time eating fruit baits, and were 7.5 times more likely to have ruptured the vaccine container of the fruit-based bait. Ferret-badgers are now recognized as rabies reservoir species in China and Taiwan, through two independent 'dog to ferret-badger' host-shift events. Species of ferret-badgers can be found throughout Indochina, where they may be an unrecognized rabies reservoir. Findings from this initial study underscore the need for further captive and field investigations of fruit-based attractants or baits developed for small meso-carnivores. Non-target mammals' competition for baits, ants, bait design, and dense tropical landscape represent potential challenges to effective ORV programs that will need to be considered in future

  7. Tandem Translation Classroom: A Case Study

    ERIC Educational Resources Information Center

    Kim, Dohun; Koh, Taejin

    2018-01-01

    The transition to student-centred learning, advances in teleconferencing tools, and active international student exchange programmes have stimulated tandem learning in many parts of the world. This pedagogical model is based on a mutual language exchange between tandem partners, where each student is a native speaker in the language the…

  8. Pen Devices for Insulin Self-Administration Compared With Needle and Vial: Systematic Review of the Literature and Meta-Analysis.

    PubMed

    Lasalvia, Pieralessandro; Barahona-Correa, Julián Esteban; Romero-Alvernia, Diana Marcela; Gil-Tamayo, Sebastián; Castañeda-Cardona, Camilo; Bayona, Juan Gabriel; Triana, Juan José; Laserna, Andrés Felipe; Mejía-Torres, Miguel; Restrepo-Jimenez, Paula; Jimenez-Zapata, Juliana; Rosselli, Diego

    2016-07-01

    Pen devices offer advantages compared with vial and syringe (VaS). The purpose of this article was to evaluate efficacy of pen devices compared to VaS. A systematic review of literature was performed in 8 different databases. References were independently screened and selected. Primary observational or experimental studies comparing pen devices with VaS for insulin administrations were included. Studies on specific populations were excluded. Risk of bias was evaluated using appropriate tools. Data on glycosylated hemoglobin (HbA1c), hypoglycemia, adherence, persistence, patient preference, and quality of life (QOL) were collected. Meta-analysis was performed when appropriate. Heterogeneity and risk of publication bias were evaluated. Otherwise, descriptive analyses of the available data was done. In all, 10 348 articles were screened. A total of 17 studies were finally selected: 7 experimental and 10 analytical. The populations of the included articles were mainly composed of adults with type 2 diabetes mellitus. Important risk of bias was found in all of the articles, particularly experimental studies. Meta-analyses were performed for HbA1c, hypoglycemia, adherence and persistence. Pen device showed better results in mean HbA1c change, patients with hypoglycemia, adherence and persistence compared to VaS. No difference was observed in number of patients achieving <7% HbA1c. Preference studies showed a tendency favoring pen devices, however nonvalidated tools were used. One QoL study showed improvements in some subscales of SF-36. There is evidence that pen devices offer benefits in clinical and, less clearly, patient-reported outcomes compared to VaS for insulin administration. However, these results should be taken with caution. © 2016 Diabetes Technology Society.

  9. Feeding Preference of Penned Whitetailed Deer for Hybrid Poplar Clones

    Treesearch

    Richard L. Verch

    1979-01-01

    Five hybrid poplar clones were presented to 16 penned white-tailed deer on a feeding board over a 3-day period in September, 1978. A definite order of preference was observed over a 3-hour period fore each of 3 trials. Over a longer period (8-24 hours), all 5 clones were completely consumed.

  10. Thermodynamic characterization of tandem mismatches found in naturally occurring RNA

    PubMed Central

    Christiansen, Martha E.; Znosko, Brent M.

    2009-01-01

    Although all sequence symmetric tandem mismatches and some sequence asymmetric tandem mismatches have been thermodynamically characterized and a model has been proposed to predict the stability of previously unmeasured sequence asymmetric tandem mismatches [Christiansen,M.E. and Znosko,B.M. (2008) Biochemistry, 47, 4329–4336], experimental thermodynamic data for frequently occurring tandem mismatches is lacking. Since experimental data is preferred over a predictive model, the thermodynamic parameters for 25 frequently occurring tandem mismatches were determined. These new experimental values, on average, are 1.0 kcal/mol different from the values predicted for these mismatches using the previous model. The data for the sequence asymmetric tandem mismatches reported here were then combined with the data for 72 sequence asymmetric tandem mismatches that were published previously, and the parameters used to predict the thermodynamics of previously unmeasured sequence asymmetric tandem mismatches were updated. The average absolute difference between the measured values and the values predicted using these updated parameters is 0.5 kcal/mol. This updated model improves the prediction for tandem mismatches that were predicted rather poorly by the previous model. This new experimental data and updated predictive model allow for more accurate calculations of the free energy of RNA duplexes containing tandem mismatches, and, furthermore, should allow for improved prediction of secondary structure from sequence. PMID:19509311

  11. Characteristic component profiling and identification of different Uncaria species based on high-performance liquid chromatography-photodiode array detection tandem ion trap and time of flight mass spectrometry coupled with rDNA ITS sequence.

    PubMed

    Zhao, Bingqiang; Huang, Yanjun; Chen, Qiulan; Chen, Qizhao; Miao, Hui; Zhu, Shuang; Zeng, Changqing

    2018-03-01

    Uncaria is a multi-source herb and its species identification has become a bottleneck in quality control. To study the identification method of different Uncaria species herbs through HPLC-MS coupled with rDNA Internal Transcribed Spacer (rDNA ITS) sequence, both plant morphological traits and molecular identification were used to determine the species of every collected Uncaria herb. The genetic analysis of different Uncaria species was performed using their rDNA ITS sequence as a molecular marker. Meanwhile, the phylogenetic relationships of 22 samples from six Uncaria species were divided and classified clearly. By optimizing the chromatographic conditions, a practical HPLC method to differentiate various varieties of Uncaria herbs was set up based on a set of characteristic components across each species. A high-performance liquid chromatography-photodiode array detector tandem ion trap and time of flight mass spectrometry technique combined with reference substances was utilized to derive 21 characteristic compounds containing six groups of six Uncaria species in China. Thus, this study provides a feasible method to solve the current problem of confusion in Uncaria species, and makes a significant step forward in the appropriate clinical use, in-depth research and further utilization of different Uncaria species. Copyright © 2017 John Wiley & Sons, Ltd.

  12. A molecular dynamics simulation study on trapping ions in a nanoscale Paul trap

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Xiongce; Krstic, Predrag S

    2008-01-01

    We found by molecular dynamics simulations that a low energy ion can be trapped effectively in a nanoscale Paul trap in both vacuum and in aqueous environment when appropriate AC/DC electric fields are applied to the system. Using the negatively charged chlorine ion as an example, we show that the trapped ion oscillates around the center of the nanotrap with the amplitude dependent on the parameters of the system and applied voltage. Successful trapping of the ion within nanoseconds requires electric bias of GHz frequency, in the range of hundreds of mV. The oscillations are damped in the aqueous environment,more » but polarization of the water molecules requires application of the higher voltage biases to reach the improved stability of the trapping. Application of a supplemental DC driving field along the trap axis can effectively drive the ion off the trap center and out of the trap, opening a possibility of studying DNA and other biological molecules using embedded probes while achieving a full control of their translocation and localization in the trap.« less

  13. The Ground-Dwelling Arthropod Community of Península Valdés in Patagonia, Argentina

    PubMed Central

    Cheli, Germán H.; Corley, J. C.; Bruzzone, O.; del Brío, M.; Martínez, F.; Román, N. Martínez; Ríos, I.

    2010-01-01

    This is the first study based on a planned and intensive sampling effort that describes the community composition and structure of the ground-dwelling arthropod assemblage of Península Valdés (Patagonia). It was carried out using pitfall traps, opened for two weeks during the summers of 2005, 2006 and 2007. A total of 28, 111 individuals were caught. Ants (Hymenoptera: Formicidae) dominated this community, followed by beetles (Coleoptera) and spiders (Araneae). The most abundant species were Pheidole bergi Mayr (Hymenoptera: Formicidae) and Blapstinus punctulatus Solier (Coleoptera: Tenebrionidae). Two new species were very recently described as new based on specimens collected during this study: Valdesiana curiosa Carpintero, Dellapé & Cheli (Hemiptera, Miridae) and Anomaloptera patagonica Dellapé & Cheli (Hemiptera, Oxycarenidae). The order Coleoptera was the most diverse taxa. The distribution of abundance data was best described by the logarithmic series model both at the family and species levels, suggesting that ecological relationships in this community could be controlled by a few factors. The community was dominated by predators from a trophic perspective. This suggests that predation acts as an important factor driving the distribution and abundances of surface-dwelling arthropods in this habitat and as such serves as a key element in understanding desert, above-ground community structure. These findings may also be useful for management and conservation purposes in arid Patagonia. PMID:20572783

  14. The ground-dwelling arthropod community of Península Valdés in Patagonia, Argentina.

    PubMed

    Cheli, Germán H; Corley, J C; Bruzzone, O; Brío, M Del; Martínez, F; Román, N Martínez; Ríos, I

    2010-01-01

    This is the first study based on a planned and intensive sampling effort that describes the community composition and structure of the ground-dwelling arthropod assemblage of Península Valdés (Patagonia). It was carried out using pitfall traps, opened for two weeks during the summers of 2005, 2006 and 2007. A total of 28,111 individuals were caught. Ants(Hymenoptera: Formicidae) dominated this community, followed by beetles (Coleoptera) and spiders (Araneae). The most abundant species were Pheidole bergi Mayr (Hymenoptera:Formicidae) and Blapstinus punctulatus Solier (Coleoptera: Tenebrionidae). Two new species were very recently described as new based on specimens collected during this study: Valdesianacuriosa Carpintero, Dellapé & Cheli (Hemiptera, Miridae) and Anomaloptera patagonica Dellapé& Cheli (Hemiptera, Oxycarenidae). The order Coleoptera was the most diverse taxa. The distribution of abundance data was best described by the logarithmic series model both at the family and species levels, suggesting that ecological relationships in this community could be controlled by a few factors. The community was dominated by predators from a trophic perspective. This suggests that predation acts as an important factor driving the distribution and abundances of surface-dwelling arthropods in this habitat and as such serves as a key element in understanding desert, above-ground community structure. These findings may also be useful for management and conservation purposes in arid Patagonia.

  15. Selecting tandem partners for silicon solar cells [Selecting tandem partners for silicon solar cells using spectral efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Zhengshan; Leilaeioun, Mehdi; Holman, Zachary

    Combining silicon and other materials in tandem solar cells is one approach to enhancing the overall power conversion efficiency of the cells. Here, we argue that top cell partners for silicon tandem solar cells should be selected on the basis of their spectral efficiency — their efficiency resolved by wavelength.

  16. Selecting tandem partners for silicon solar cells [Selecting tandem partners for silicon solar cells using spectral efficiency

    DOE PAGES

    Yu, Zhengshan; Leilaeioun, Mehdi; Holman, Zachary

    2016-09-26

    Combining silicon and other materials in tandem solar cells is one approach to enhancing the overall power conversion efficiency of the cells. Here, we argue that top cell partners for silicon tandem solar cells should be selected on the basis of their spectral efficiency — their efficiency resolved by wavelength.

  17. Insulin Pen—The “iPod” for Insulin Delivery (Why Pen Wins over Syringe)

    PubMed Central

    Asamoah, Ernest

    2008-01-01

    Diabetes affects most aspects of everyday life and places considerable responsibility on the patient; therefore, without patient acceptance of what we offer, the therapy is unlikely to be adhered to especially when that therapy happens to be insulin injection. In 2008, almost every physician/health care provider carries new and sleek cell phones (because the newer ones are well designed and function better). Why these same providers continue to prescribe insulin via syringes in 2008 is something that I cannot fathom. Previously, some insurance companies only paid for vials and there was no other choice, but today almost all insurance pay for pens and so the “insurance reason” is no longer tenable. Since Banting and Best discovered insulin in 1921, scientists have continued to improve the types of insulin (making them mimic physiology more closely in order to minimize hypoglycemia and improve glycemic control as seen with the latest analog insulins). In the same manner, the delivery process of insulin has also continued to evolve to make it easier and more acceptable to patients. Studies have shown that patients prefer device use over traditional vials/syringes. Pen devices used to inject insulin lead to better compliance, are quicker to inject, dosing is much more accurate, and, surprisingly, are more cost effective. I challenge my colleagues to take full responsibility for what their patients use. If a provider believes in pen devices, most of his/her patients will use them. The products your patients use is a direct reflection of what you practice. Educating providers to change their beliefs and practices is key to moving American diabetic patients from syringes to pen devices. PMID:19885358

  18. Sorption vacuum trap

    NASA Technical Reports Server (NTRS)

    Barrington, A. E.; Caruso, A. J.

    1970-01-01

    Modified sorption trap for use in high vacuum systems contains provisions for online regeneration of sorbent material. Trap is so constructed that it has a number of encapsulated resistance heaters and a valving and pumping device for removing gases from heated sorbing material. Excessive downtime is eliminated with this trap.

  19. Influence of trap location on the efficiency of trapping in dendrimers and regular hyperbranched polymers.

    PubMed

    Lin, Yuan; Zhang, Zhongzhi

    2013-03-07

    The trapping process in polymer systems constitutes a fundamental mechanism for various other dynamical processes taking place in these systems. In this paper, we study the trapping problem in two representative polymer networks, Cayley trees and Vicsek fractals, which separately model dendrimers and regular hyperbranched polymers. Our goal is to explore the impact of trap location on the efficiency of trapping in these two important polymer systems, with the efficiency being measured by the average trapping time (ATT) that is the average of source-to-trap mean first-passage time over every staring point in the whole networks. For Cayley trees, we derive an exact analytic formula for the ATT to an arbitrary trap node, based on which we further obtain the explicit expression of ATT for the case that the trap is uniformly distributed. For Vicsek fractals, we provide the closed-form solution for ATT to a peripheral node farthest from the central node, as well as the numerical solutions for the case when the trap is placed on other nodes. Moreover, we derive the exact formula for the ATT corresponding to the trapping problem when the trap has a uniform distribution over all nodes. Our results show that the influence of trap location on the trapping efficiency is completely different for the two polymer networks. In Cayley trees, the leading scaling of ATT increases with the shortest distance between the trap and the central node, implying that trap's position has an essential impact on the trapping efficiency; while in Vicsek fractals, the effect of location of the trap is negligible, since the dominant behavior of ATT is identical, respective of the location where the trap is placed. We also present that for all cases of trapping problems being studied, the trapping process is more efficient in Cayley trees than in Vicsek fractals. We demonstrate that all differences related to trapping in the two polymer systems are rooted in their underlying topological structures.

  20. Funnel traps capture a higher proportion of juvenile Great Tits Parus major than automatic traps

    USGS Publications Warehouse

    Senar, J.C.; Domenech, J.; Conroy, M.J.

    1999-01-01

    We compared capture rates of Great Tits at funnel traps, where several birds can be captured at once so that some decoy effect may appear, to those obtained at automatic traps, where only one bird can be trapped at a time, at trapping stations in northeastern Spain. Juvenile birds were mainly captured at funnel traps (79% of juvenile captures), whereas adult plumaged birds were captured at both types of traps (51% of captures were at the funnel traps) (test between ages, P<0.001). Juvenile Great Tits had lower body condition as measured by ptilochronology (P<0.01). These birds are more easily trapped in funnel traps, which may be acting as decoy traps, and thus are vulnerable to the same kinds of biases (eg age or body condition) that have been previously documented for decoy traps.

  1. Tandem junction amorphous silicon solar cells

    DOEpatents

    Hanak, Joseph J.

    1981-01-01

    An amorphous silicon solar cell has an active body with two or a series of layers of hydrogenated amorphous silicon arranged in a tandem stacked configuration with one optical path and electrically interconnected by a tunnel junction. The layers of hydrogenated amorphous silicon arranged in tandem configuration can have the same bandgap or differing bandgaps.

  2. CAS or Pen-and-Paper: Factors That Influence Students' Choices

    ERIC Educational Resources Information Center

    Cameron, Scott; Ball, Lynda

    2015-01-01

    This paper reports on a study of choices about the use of a computer algebra system (CAS) or pen-and-paper (p&p) by a class of seven Year 11 Mathematical Methods (CAS) students as they completed a calculus worksheet. Factors that influenced students' choices are highlighted by comparing and contrasting the use of CAS and p&p between…

  3. Prediction of Genetic Values for Feed Intake from Individual Body Weight Gain and Total Feed Intake of the Pen

    USDA-ARS?s Scientific Manuscript database

    Records of individual feed intake (FI) and gain (G) were obtained from the Germ Plasm Evaluation (GPE) program at US Meat Animal Research Center (USMARC). Animals were randomly assigned to pens. Only pens with 6 to 9 steers were used for this study (Data Set 1,289 steers). Variance components and g...

  4. Energy & mass-charge distribution peculiarities of ion emitted from penning source

    NASA Astrophysics Data System (ADS)

    Mamedov, N. V.; Kolodko, D. V.; Sorokin, I. A.; Kanshin, I. A.; Sinelnikov, D. N.

    2017-05-01

    The optimization of hydrogen Penning sources used, in particular, in plasma chemical processing of materials and DLC deposition, is still very important. Investigations of mass-charge composition of these ion source emitted beams are particular relevant for miniature linear accelerators (neutron flux generators) nowadays. The Penning ion source energy and mass-charge ion distributions are presented. The relation between the discharge current abrupt jumps with increasing plasma density in the discharge center and increasing potential whipping (up to 50% of the anode voltage) is shown. Also the energy spectra in the discharge different modes as the pressure and anode potential functions are presented. It has been revealed that the atomic hydrogen ion concentration is about 5-10%, and it weakly depends on the pressure and the discharge current (in the investigated range from 1 to 10 mTorr and from 50 to 1000 μA) and increases with the anode voltage (up 1 to 3,5 kV).

  5. Dynamic analysis of trapping and escaping in dual beam optical trap

    NASA Astrophysics Data System (ADS)

    Li, Wenqiang; Hu, Huizhu; Su, Heming; Li, Zhenggang; Shen, Yu

    2016-10-01

    In this paper, we simulate the dynamic movement of a dielectric sphere in optical trap. This dynamic analysis can be used to calibrate optical forces, increase trapping efficiency and measure viscous coefficient of surrounding medium. Since an accurate dynamic analysis is based on a detailed force calculation, we calculate all forces a sphere receives. We get the forces of dual-beam gradient radiation pressure on a micron-sized dielectric sphere in the ray optics regime and utilize Einstein-Ornstein-Uhlenbeck to deal with its Brownian motion forces. Hydrodynamic viscous force also exists when the sphere moves in liquid. Forces from buoyance and gravity are also taken into consideration. Then we simulate trajectory of a sphere when it is subject to all these forces in a dual optical trap. From our dynamic analysis, the sphere can be trapped at an equilibrium point in static water, although it permanently fluctuates around the equilibrium point due to thermal effects. We go a step further to analyze the effects of misalignment of two optical traps. Trapping and escaping phenomena of the sphere in flowing water are also simulated. In flowing water, the sphere is dragged away from the equilibrium point. This dragging distance increases with the decrease of optical power, which results in escaping of the sphere with optical power below a threshold. In both trapping and escaping process we calculate the forces and position of the sphere. Finally, we analyze a trapping region in dual optical tweezers.

  6. Utilization of squid pen for the efficient production of chitosanase and antioxidants through prolonged autoclave treatment.

    PubMed

    Wang, San-Lang; Wu, Pei-Chen; Liang, Tzu-Wen

    2009-05-26

    We have developed a culture system for efficient production of chitosanase by Bacillus sp. TKU004. TKU004 was cultivated by using squid pen powder as the sole carbon/nitrogen source. The effects of autoclave treatments of the medium on the production of chitosanase were investigated. Autoclave treatment of squid pen powder for 45 min remarkably promoted enzyme productivity. When the culture medium containing an initial squid pen powder concentration of 3% was autoclaved for 45 min, the chitosanase activity was optimal and reached 0.14-0.16 U/mL. In addition, extracellular surfactant-stable chitosanase was purified from the TKU004 culture supernatant. The antioxidant activity of TKU004 culture supernatant was determined through the scavenging ability of DPPH, with 70% per mL. With this method, we have shown that marine wastes can be utilized efficiently through prolonged autoclave treatments to generate a high value-added product, and have revealed its hidden potential in the production of functional foods.

  7. A Review of Insulin Pen Devices and Use in the Elderly Diabetic Population

    PubMed Central

    Wright, Bradley M.; Bellone, Jessica M.; McCoy, Emily K.

    2010-01-01

    The prevalence of diabetes mellitus (DM) in the elderly population currently represents almost one-half of the overall diabetic population. Treatment of DM often requires a multidrug regimen that includes insulin therapy; however, due to concomitant comorbidities such as dementia, vision loss, neuropathies, poor mobility, and poor manual dexterity, elderly patients may be at increase risk for hypoglycemia and other dosing errors that are associated with insulin administration. Insulin pen devices have been shown to provide more reliable, accurate, and simplified dosing, and therefore may be a safer, easier, and more acceptable method of insulin delivery in the elderly population. This review will describe the various insulin pen devices available today, as well as discuss the potential advantages of these devices in the elderly population. PMID:22879787

  8. Comprehension of handwriting development: Pen-grip kinetics in handwriting tasks and its relation to fine motor skills among school-age children.

    PubMed

    Lin, Yu-Chen; Chao, Yen-Li; Wu, Shyi-Kuen; Lin, Ho-Hsio; Hsu, Chieh-Hsiang; Hsu, Hsiao-Man; Kuo, Li-Chieh

    2017-10-01

    Numerous tools have been developed to evaluate handwriting performances by analysing written products. However, few studies have directly investigated kinetic performances of digits when holding a pen. This study thus attempts to investigate pen-grip kinetics during writing tasks of school-age children and explore the relationship between the kinetic factors and fine motor skills. This study recruited 181 children aged from 5 to 12 years old and investigated the effects of age on handwriting kinetics and the relationship between these and fine motor skills. The forces applied from the digits and pen-tip were measured during writing tasks via a force acquisition pen, and the children's fine motor performances were also evaluated. The results indicate that peak force and average force might not be direct indicators of handwriting performance for normally developing children at this age. Younger children showed larger force variation and lower adjustment frequency during writing, which might indicate they had poorer force control than the older children. Force control when handling a pen is significantly correlated with fine motor performance, especially in relation to the manual dexterity. A novel system is proposed for analysing school-age children's force control while handwriting. We observed the development of force control in relation to pen grip among the children with different ages in this study. The findings suggested that manipulation skill may be crucial when children are establishing their handwriting capabilities. © 2017 Occupational Therapy Australia.

  9. The structure and stratigraphy of the Pen Argyl Member of the Martinsburg Formation in Lehigh and Berks counties, Pennsylvania

    USGS Publications Warehouse

    Lash, Gary George

    1978-01-01

    The Pen Argyl Member, the upper claystone slate member of the Martinsburg Formation, was studied in three quadrangles in Lehigh and Berks Counties, Pennsylvania. Graptolites collected from the Pen Argyl Member at Lehigh Gap indicate a lower Upper Ordovician (Edenian-Maysvillian) age for the Pen Argyl Member. The Pen Argyl Member in this area is located on the normal limb and in the brow of the large, recumbent Musconetcong nappe. It is a deep water flysch deposit emplaced by turbidity currents from a southeasterly source. Sedimentologic and structural evidence show that the Pen Argyl member overlies the sandy middle Ramseyburg Member, thus supporting the tripartite subdivision of the Martinsburg Formation. Field and thin section study indicates that the penetrative slaty cleavage formed in an indurated rock probably by pressure solution and neocrystallization under lower greenschist facies metamorphism. Strain-slip cleavage formed as a result of a stress couple operating parallel to the slaty cleavage that transposed the slaty cleavage into a more spaced cleavage. Both cleavages are believed to have formed within the same stress continuum and in close succession. Analysis of the folds in the Pen Argyl Member indicate six phases of major and minor folding. The earliest folding, F1, resulted in the development of the recumbent nappe. F2 folds can only be determined statistically; these axes plunge either northeast or southwest Asymmetric folds, F3, and associated F4 crenulations formed within the same stress continuum. F5 folds are large open folds and are exemplified by the Mosservi!le anticline. Kink folds, F6 and associated crenulations are fault related and were the last folds to form. Faults in the Pen Argyl Member range from small displacements along slaty cleavage to large reverse faults. The largest of these, the Eckville fault, is recognized throughout the three quadrangle area. It is a high angle reverse fault that separates the Shochary sequence from the

  10. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR LIGHT PEN OPERATION AND VERIFICATION OF SCANNED BAR CODES (UA-D-33.0)

    EPA Science Inventory

    The purpose of this SOP is to define the steps needed to operate the light pens, and verify the values produced by light pens used in the Arizona NHEXAS project and the Border study. Keywords: data; equipment; light pens.

    The U.S.-Mexico Border Program is sponsored by the Envir...

  11. Magnetic trapping of neutrons

    PubMed

    Huffman; Brome; Butterworth; Coakley; Dewey; Dzhosyuk; Golub; Greene; Habicht; Lamoreaux; Mattoni; McKinsey; Wietfeldt; Doyle

    2000-01-06

    Accurate measurement of the lifetime of the neutron (which is unstable to beta decay) is important for understanding the weak nuclear force and the creation of matter during the Big Bang. Previous measurements of the neutron lifetime have mainly been limited by certain systematic errors; however, these could in principle be avoided by performing measurements on neutrons stored in a magnetic trap. Neutral-particle and charged-particle traps are widely used for studying both composite and elementary particles, because they allow long interaction times and isolation of particles from perturbing environments. Here we report the magnetic trapping of neutrons. The trapping region is filled with superfluid 4He, which is used to load neutrons into the trap and as a scintillator to detect their decay. Neutrons in the trap have a lifetime of 750(+330)(-200) seconds, mainly limited by their beta decay rather than trap losses. Our experiment verifies theoretical predictions regarding the loading process and magnetic trapping of neutrons. Further refinement of this method should lead to improved precision in the neutron lifetime measurement.

  12. Privacy Act System of Records - Passport Expiration Notification System (PENS) - EPA-72

    EPA Pesticide Factsheets

    Creation of a new system of records for the Passport Expiration Notification System (PENS). The purpose of the system is to assist in requesting and obtaining country clearances for EPA staff traveling to foreign countries to conduct government business.

  13. Deuterium trapping in tungsten

    NASA Astrophysics Data System (ADS)

    Poon, Michael

    Tungsten is one of the primary material candidates being investigated for use in the first-wall of a magnetic confinement fusion reactor. An ion accelerator was used to simulate the type of ion interaction that may occur at a plasma-facing material. Thermal desorption spectroscopy (TDS) was the primary tool used to analyze the effects of the irradiation. Secondary ion mass spectroscopy (SIMS) was used to determine the distribution of trapped D in the tungsten specimen. The tritium migration analysis program (TMAP) was used to simulate thermal desorption profiles from the D depth distributions. Fitting of the simulated thermal desorption profiles with the measured TDS results provided values of the D trap energies. Deuterium trapping in single crystal tungsten was studied as a function of the incident ion fluence, ion flux, irradiation temperature, irradiation history, and surface impurity levels during irradiation. The results show that deuterium was trapped at vacancies and voids. Two deuterium atoms could be trapped at a tungsten vacancy, with trapping energies of 1.4 eV and 1.2 eV for the first and second D atoms, respectively. In a tungsten void, D is trapped as atoms adsorbed on the inner walls of the void with a trap energy of 2.1 eV, or as D2 molecules inside the void with a trap energy of 1.2 eV. Deuterium trapping in polycrystalline tungsten was also studied as a function of the incident fluence, irradiation temperature, and irradiation history. Deuterium trapping in polycrystalline tungsten also occurs primarily at vacancies and voids with the same trap energies as in single crystal tungsten; however, the presence of grain boundaries promotes the formation of large surface blisters with high fluence irradiations at 500 K. In general, D trapping is greater in polycrystalline tungsten than in single crystal tungsten. To simulate mixed materials comprising of carbon (C) and tungsten, tungsten specimens were pre-irradiated with carbon ions prior to D

  14. Determination of sulfonamide antibiotics and metabolites in liver, muscle and kidney samples by pressurized liquid extraction or ultrasound-assisted extraction followed by liquid chromatography-quadrupole linear ion trap-tandem mass spectrometry (HPLC-QqLIT-MS/MS).

    PubMed

    Hoff, Rodrigo Barcellos; Pizzolato, Tânia Mara; Peralba, Maria do Carmo Ruaro; Díaz-Cruz, M Silvia; Barceló, Damià

    2015-03-01

    Sulfonamides are widely used in human and veterinary medicine. The presence of sulfonamides residues in food is an issue of great concern. Throughout the present work, a method for the targeted analysis of 16 sulfonamides and metabolites residue in liver of several species has been developed and validated. Extraction and clean-up has been statistically optimized using central composite design experiments. Two extraction methods have been developed, validated and compared: i) pressurized liquid extraction, in which samples were defatted with hexane and subsequently extracted with acetonitrile and ii) ultrasound-assisted extraction with acetonitrile and further liquid-liquid extraction with hexane. Extracts have been analyzed by liquid chromatography-quadrupole linear ion trap-tandem mass spectrometry. Validation procedure has been based on the Commission Decision 2002/657/EC and included the assessment of parameters such as decision limit (CCα), detection capability (CCβ), sensitivity, selectivity, accuracy and precision. Method׳s performance has been satisfactory, with CCα values within the range of 111.2-161.4 µg kg(-1), limits of detection of 10 µg kg(-1) and accuracy values around 100% for all compounds. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. High-Efficiency Polycrystalline Thin Film Tandem Solar Cells.

    PubMed

    Kranz, Lukas; Abate, Antonio; Feurer, Thomas; Fu, Fan; Avancini, Enrico; Löckinger, Johannes; Reinhard, Patrick; Zakeeruddin, Shaik M; Grätzel, Michael; Buecheler, Stephan; Tiwari, Ayodhya N

    2015-07-16

    A promising way to enhance the efficiency of CIGS solar cells is by combining them with perovskite solar cells in tandem devices. However, so far, such tandem devices had limited efficiency due to challenges in developing NIR-transparent perovskite top cells, which allow photons with energy below the perovskite band gap to be transmitted to the bottom cell. Here, a process for the fabrication of NIR-transparent perovskite solar cells is presented, which enables power conversion efficiencies up to 12.1% combined with an average sub-band gap transmission of 71% for photons with wavelength between 800 and 1000 nm. The combination of a NIR-transparent perovskite top cell with a CIGS bottom cell enabled a tandem device with 19.5% efficiency, which is the highest reported efficiency for a polycrystalline thin film tandem solar cell. Future developments of perovskite/CIGS tandem devices are discussed and prospects for devices with efficiency toward and above 27% are given.

  16. Evaluation method for acoustic trapping performance by tracking motion of trapped microparticle

    NASA Astrophysics Data System (ADS)

    Lim, Hae Gyun; Ham Kim, Hyung; Yoon, Changhan

    2018-05-01

    We report a method to evaluate the performances of a single-beam acoustic tweezer using a high-frequency ultrasound transducer. The motion of a microparticle trapped by a 45-MHz single-element transducer was captured and analyzed to deduce the magnitude of trapping force. In the proposed method, the motion of a trapped microparticle was analyzed from a series of microscopy images to compute trapping force; thus, no additional equipment such as microfluidics is required. The method could be used to estimate the effective trapping force in an acoustic tweezer experiment to assess cell membrane deformability by attaching a microbead to the surface of a cell and tracking the motion of the trapped bead, which is similar to a bead-based assay that uses optical tweezers. The results showed that the trapping force increased with increasing acoustic intensity and duty factor, but the force eventually reached a plateau at a higher acoustic intensity. They demonstrated that this method could be used as a simple tool to evaluate the performance and to optimize the operating conditions of acoustic tweezers.

  17. Penning Ionization: Measurement of Ion and Molecular Lifetimes.

    DTIC Science & Technology

    1977-12-01

    State of CH", James Carozza and Richard Anderson, J. Opt. Soc. Am. 67, 118 (1977). "Spin & Coherence Transfer in Penning Ionization", L.D. Schearer...Lamp , F. Rev. Sei. Instru. 48, 92 (1977). _^^ ^rtjri ’’Radiative Lifetime of the PrÄ State of CH , James Carroza and Richard ’ Anderson, J. Opt...lr.h .--.- •’••• —•;••.: — - ----- Radiative lifetime of the A2A state of CHr James Carozza and Richard Anderson Drparimem 0/ Physics

  18. Serologic surveillance of wild and pen-reared ring-necked pheasants (Phasianus colchicus) as a method of understanding disease reservoirs

    USGS Publications Warehouse

    Dwight, Ian; Coates, Peter S.; Stoute, Simone T.; Senties-Cue, C. Gabriel; Gharpure, Radhika V.; Pitesky, Maurice E.

    2018-01-01

    We investigated exposure to infectious diseases in wild (n=33) and pen-reared (n=12) Ring-necked Pheasants (Phasianus colchicus) in the Central Valley of California during 2014 and 2015. Serologic tests were positive for antibodies against hemorrhagic enteritis (HE), infectious bursal disease (IBD), and Newcastle disease (ND) viruses in both wild and pen-reared pheasants.

  19. Cost minimization analysis of different growth hormone pen devices based on time-and-motion simulations

    PubMed Central

    2010-01-01

    Background Numerous pen devices are available to administer recombinant Human Growth Hormone (rhGH), and both patients and health plans have varying issues to consider when selecting a particular product and device for daily use. Therefore, the present study utilized multi-dimensional product analysis to assess potential time involvement, required weekly administration steps, and utilization costs relative to daily rhGH administration. Methods Study objectives were to conduct 1) Time-and-Motion (TM) simulations in a randomized block design that allowed time and steps comparisons related to rhGH preparation, administration and storage, and 2) a Cost Minimization Analysis (CMA) relative to opportunity and supply costs. Nurses naïve to rhGH administration and devices were recruited to evaluate four rhGH pen devices (2 in liquid form, 2 requiring reconstitution) via TM simulations. Five videotaped and timed trials for each product were evaluated based on: 1) Learning (initial use instructions), 2) Preparation (arrange device for use), 3) Administration (actual simulation manikin injection), and 4) Storage (maintain product viability between doses), in addition to assessment of steps required for weekly use. The CMA applied micro-costing techniques related to opportunity costs for caregivers (categorized as wages), non-drug medical supplies, and drug product costs. Results Norditropin® NordiFlex and Norditropin® NordiPen (NNF and NNP, Novo Nordisk, Inc., Bagsværd, Denmark) took less weekly Total Time (p < 0.05) to use than either of the comparator products, Genotropin® Pen (GTP, Pfizer, Inc, New York, New York) or HumatroPen® (HTP, Eli Lilly and Company, Indianapolis, Indiana). Time savings were directly related to differences in new package Preparation times (NNF (1.35 minutes), NNP (2.48 minutes) GTP (4.11 minutes), HTP (8.64 minutes), p < 0.05)). Administration and Storage times were not statistically different. NNF (15.8 minutes) and NNP (16.2 minutes) also

  20. Single-run determination of polybrominated diphenyl ethers (PBDEs) di- to deca-brominated in fish meal, fish oil and fish feed by isotope dilution: application of automated sample purification and gas chromatography/ion trap tandem mass spectrometry (GC/ITMS).

    PubMed

    Blanco, Sonia Lucía; Vieites, Juan M

    2010-07-05

    The present paper describes the application of automated cleanup and fractionation procedures of the Power Prep system (Fluid Management Systems) for the determination of polybrominated diphenyl ethers (PBDEs) in feeding stuffs and fish meal and oil. Gas chromatography (GC) separation followed by ion trap tandem mass spectrometry detection in EI mode (ITMS) allowed the analysis of di- to deca-BDEs in the samples matrices used in fish aquaculture. The method developed enabled the determination of 26 native PBDE congeners and 11 (13)C(12)-labelled congeners, including deca-BDE 209, in a single-run analysis, using isotope dilution. The automated cleanup, consisting of a succession of multilayer silica and basic alumina columns previously applied by Wyrzykowska et al. (2009) [28] in combustion flue gas, was successfully applied in our complex matrices. The method allowed an increase in productivity, i.e. lower time was required to process samples, and simultaneous purification of several samples was achieved at a time, reducing analyst dedication and human error input. Average recoveries of 43-96% were obtained. GC/ITMS can overcome the complexity originating from the sample matrix, eliminating matrix effects by tandem MS, to enable the detection of congeners penta- to nona-BDEs where interferent masses were present. The provisional detection limits, estimated in the samples, were 5-30 pg for di-, tri-, tetra-, and penta-BDEs, 20-65 pg for hexa-, hepta-, octa- and nona-BDEs, and 105 pg for deca-BDE. Reduction of deca-BDE 209 blank values is of concern to ongoing research. Good accuracy was obtained by application of the whole procedure, representing an efficient, low-cost and fast alternative for routine analyses. Copyright 2010 Elsevier B.V. All rights reserved.

  1. NeuroPigPen: A Scalable Toolkit for Processing Electrophysiological Signal Data in Neuroscience Applications Using Apache Pig.

    PubMed

    Sahoo, Satya S; Wei, Annan; Valdez, Joshua; Wang, Li; Zonjy, Bilal; Tatsuoka, Curtis; Loparo, Kenneth A; Lhatoo, Samden D

    2016-01-01

    The recent advances in neurological imaging and sensing technologies have led to rapid increase in the volume, rate of data generation, and variety of neuroscience data. This "neuroscience Big data" represents a significant opportunity for the biomedical research community to design experiments using data with greater timescale, large number of attributes, and statistically significant data size. The results from these new data-driven research techniques can advance our understanding of complex neurological disorders, help model long-term effects of brain injuries, and provide new insights into dynamics of brain networks. However, many existing neuroinformatics data processing and analysis tools were not built to manage large volume of data, which makes it difficult for researchers to effectively leverage this available data to advance their research. We introduce a new toolkit called NeuroPigPen that was developed using Apache Hadoop and Pig data flow language to address the challenges posed by large-scale electrophysiological signal data. NeuroPigPen is a modular toolkit that can process large volumes of electrophysiological signal data, such as Electroencephalogram (EEG), Electrocardiogram (ECG), and blood oxygen levels (SpO2), using a new distributed storage model called Cloudwave Signal Format (CSF) that supports easy partitioning and storage of signal data on commodity hardware. NeuroPigPen was developed with three design principles: (a) Scalability-the ability to efficiently process increasing volumes of data; (b) Adaptability-the toolkit can be deployed across different computing configurations; and (c) Ease of programming-the toolkit can be easily used to compose multi-step data processing pipelines using high-level programming constructs. The NeuroPigPen toolkit was evaluated using 750 GB of electrophysiological signal data over a variety of Hadoop cluster configurations ranging from 3 to 30 Data nodes. The evaluation results demonstrate that the toolkit

  2. [A comparison of rebound tonometry (ICare) with TonoPenXL and Goldmann applanation tonometry].

    PubMed

    Schreiber, W; Vorwerk, C K; Langenbucher, A; Behrens-Baumann, W; Viestenz, A

    2007-04-01

    Goldmann applanation tonometry and dynamic contour tonometry (PASCAL) are two well established slit lamp mounted tonometric methods. Intraocular pressure measurement in bedridden patients and children is often only possible using hand held tonometers (TonoPenXL, Perkins tonometer, Draeger tonometer). This study was performed to evaluate the hand held ICare tonometer, which is based on the rebound method. A total of 102 eyes were examined by two highly experienced ophthalmologists for: 1) ophthalmological status, 2) central corneal power (Zeiss IOL-Master), 3) central corneal thickness (Tomey ultrasound pachymetry, five successive measurements, SD<5%), 4) intraocular pressure (IOP) measurement with the Goldmann applantation tonometer (GAT) 1x, 5) TonoPenXL (1x), 6) ICare with three successive measurement series of 6 single measurements. The mean IOP(GAT) was 13.2+/-3.0 mmHg compared with the mean IOP(TonoPenXL) (13.4+/-3.1 mmHg) and with the IOP(ICare) (mean value of first measurement series: 13.4+/-3.1 mmHg). The series of measurements with the ICare showed a tonography effect (decrease of IOP from 14.6 mmHg at the first measurement and 14.2 mmHg at the second to 14.0 at the third measurement). The ICare-measurements were highly reliable (Cronbach's alpha=0.974) and showed a good correlation between the measurement series (r=0.592-0.642; p<0.001). There was a great intra-individual variability of up to 17 mmHg between the GAT, TonoPenXL and ICare methods. The ICare tonometer is easy to handle and high reliability. The data are comparable with those from the Goldmann tonometer. A tonography effect of 0.6 mmHg in the successive measurement series was found.

  3. Recent advances of liquid chromatography-(tandem) mass spectrometry in clinical and forensic toxicology.

    PubMed

    Peters, Frank T

    2011-01-01

    Liquid chromatography (LC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) has become increasingly important in clinical and forensic toxicology as well as doping control and is now a robust and reliable technique for routine analysis in these fields. In recent years, methods for LC-MS(/MS)-based systematic toxicological analysis using triple quadrupole or ion trap instruments have been considerably improved and a new screening approach based on high-resolution MS analysis using benchtop time-of-flight MS instruments has been developed. Moreover, many applications for so-called multi-target screening and/or quantification of drugs, poisons, and or their metabolites in various biomatrices have been published. The present paper will provide an overview and discuss these recent developments focusing on the literature published after 2006. Copyright © 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Potential harmful health effects of inhaling nicotine-free shisha-pen vapor: a chemical risk assessment of the main components propylene glycol and glycerol.

    PubMed

    Kienhuis, Anne S; Soeteman-Hernandez, Lya G; Bos, Peter Mj; Cremers, Hans Wjm; Klerx, Walther N; Talhout, Reinskje

    2015-01-01

    A shisha-pen is an electronic cigarette variant that is advertised to mimic the taste of a water pipe, or shisha. The aim of this study was to assess the potential harmful health effects caused by inhaling the vapor of a nicotine-free shisha-pen. Gas chromatography analysis was performed to determine the major components in shisha-pen vapor. Risk assessment was performed using puff volumes of e-cigarettes and "normal" cigarettes and a 1-puff scenario (one-time exposure). The concentrations that reached the airways and lungs after using a shisha-pen were calculated and compared to data from published toxicity studies. The main components in shisha-pen vapor are propylene glycol and glycerol (54%/46%). One puff (50 to 70 mL) results in exposure of propylene glycol and glycerol of 430 to 603 mg/m(3) and 348 to 495 mg/m(3), respectively. These exposure concentrations were higher than the points of departure for airway irritation based on a human study (propylene glycol, mean concentration of 309 mg/m(3)) and a rat study (glycerol, no-observed adverse effect level of 165 mg/m(3)). Already after one puff of the shisha-pen, the concentrations of propylene glycol and glycerol are sufficiently high to potentially cause irritation of the airways. New products such as the shisha-pen should be detected and risks should be assessed to inform regulatory actions aimed at limiting potential harm that may be caused to consumers and protecting young people to take up smoking.

  5. Trapped nonneutral plasmas, liquids, and crystals (the thermal equilibrium states)

    NASA Astrophysics Data System (ADS)

    Dubin, Daniel H.; O'neil, T. M.

    1999-01-01

    Plasmas consisting exclusively of particles with a single sign of charge (e.g., pure electron plasmas and pure ion plasmas) can be confined by static electric and magnetic fields (in a Penning trap) and also be in a state of global thermal equilibrium. This important property distinguishes these totally unneutralized plasmas from neutral and quasineutral plasmas. This paper reviews the conditions for, and the structure of, the thermal equilibrium states. Both theory and experiment are discussed, but the emphasis is decidedly on theory. It is a huge advantage to be able to use thermal equilibrium statistical mechanics to describe the plasma state. Such a description is easily obtained and complete, including for example the details of the plasma shape and microscopic order. Pure electron and pure ion plasmas are routinely confined for hours and even days, and thermal equilibrium states are observed. These plasmas can be cooled to the cryogenic temperature range, where liquid and crystal-like states are realized. The authors discuss the structure of the correlated states separately for three plasma sizes: large plasmas, in which the free energy is dominated by the bulk plasma; mesoscale plasmas, in which the free energy is strongly influenced by the surface; and Coulomb clusters, in which the number of particles is so small that the canonical ensemble is not a good approximation for the microcanonical ensemble. All three cases have been studied through numerical simulations, analytic theory, and experiment. In addition to describing the structure of the thermal equilibrium states, the authors develop a thermodynamic theory of the trapped plasma system. Thermodynamic inequalities and Maxwell relations provide useful bounds on and general relationships between partial derivatives of the various thermodynamic variables.

  6. Form-Focused Interaction in Online Tandem Learning

    ERIC Educational Resources Information Center

    O'Rourke, Breffni

    2005-01-01

    Tandem language learning--a configuration involving pairs of learners with complementary target/native languages--is an underexploited but potentially very powerful use of computer-mediated communication (CMC) in second-language pedagogy. Tandem offers the benefits of authentic, culturally grounded interaction, while also promoting a pedagogical…

  7. Microfabricated ion trap array

    DOEpatents

    Blain, Matthew G [Albuquerque, NM; Fleming, James G [Albuquerque, NM

    2006-12-26

    A microfabricated ion trap array, comprising a plurality of ion traps having an inner radius of order one micron, can be fabricated using surface micromachining techniques and materials known to the integrated circuits manufacturing and microelectromechanical systems industries. Micromachining methods enable batch fabrication, reduced manufacturing costs, dimensional and positional precision, and monolithic integration of massive arrays of ion traps with microscale ion generation and detection devices. Massive arraying enables the microscale ion traps to retain the resolution, sensitivity, and mass range advantages necessary for high chemical selectivity. The reduced electrode voltage enables integration of the microfabricated ion trap array with on-chip circuit-based rf operation and detection electronics (i.e., cell phone electronics). Therefore, the full performance advantages of the microfabricated ion trap array can be realized in truly field portable, handheld microanalysis systems.

  8. Electronic Tandem Language Learning (eTandem): A Third Approach to Second Language Learning for the 21st Century

    ERIC Educational Resources Information Center

    Cziko, Gary A.

    2004-01-01

    Tandem language learning occurs when two learners of different native languages work together to help each other learn the other language. First used in face-to-face contexts, Tandem is now increasingly being used by language-learning partners located in different countries who are linked via various forms of electronic communication, a context…

  9. Development of large volume double ring penning plasma discharge source for efficient light emissions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prakash, Ram; Vyas, Gheesa Lal; Jain, Jalaj

    In this paper, the development of large volume double ring Penning plasma discharge source for efficient light emissions is reported. The developed Penning discharge source consists of two cylindrical end cathodes of stainless steel having radius 6 cm and a gap 5.5 cm between them, which are fitted in the top and bottom flanges of the vacuum chamber. Two stainless steel anode rings with thickness 0.4 cm and inner diameters 6.45 cm having separation 2 cm are kept at the discharge centre. Neodymium (Nd{sub 2}Fe{sub 14}B) permanent magnets are physically inserted behind the cathodes for producing nearly uniform magnetic fieldmore » of {approx}0.1 T at the center. Experiments and simulations have been performed for single and double anode ring configurations using helium gas discharge, which infer that double ring configuration gives better light emissions in the large volume Penning plasma discharge arrangement. The optical emission spectroscopy measurements are used to complement the observations. The spectral line-ratio technique is utilized to determine the electron plasma density. The estimated electron plasma density in double ring plasma configuration is {approx}2 Multiplication-Sign 10{sup 11} cm{sup -3}, which is around one order of magnitude larger than that of single ring arrangement.« less

  10. Development of large volume double ring penning plasma discharge source for efficient light emissions.

    PubMed

    Prakash, Ram; Vyas, Gheesa Lal; Jain, Jalaj; Prajapati, Jitendra; Pal, Udit Narayan; Chowdhuri, Malay Bikas; Manchanda, Ranjana

    2012-12-01

    In this paper, the development of large volume double ring Penning plasma discharge source for efficient light emissions is reported. The developed Penning discharge source consists of two cylindrical end cathodes of stainless steel having radius 6 cm and a gap 5.5 cm between them, which are fitted in the top and bottom flanges of the vacuum chamber. Two stainless steel anode rings with thickness 0.4 cm and inner diameters 6.45 cm having separation 2 cm are kept at the discharge centre. Neodymium (Nd(2)Fe(14)B) permanent magnets are physically inserted behind the cathodes for producing nearly uniform magnetic field of ~0.1 T at the center. Experiments and simulations have been performed for single and double anode ring configurations using helium gas discharge, which infer that double ring configuration gives better light emissions in the large volume Penning plasma discharge arrangement. The optical emission spectroscopy measurements are used to complement the observations. The spectral line-ratio technique is utilized to determine the electron plasma density. The estimated electron plasma density in double ring plasma configuration is ~2 × 10(11) cm(-3), which is around one order of magnitude larger than that of single ring arrangement.

  11. Optimization of multifunnel traps for emerald ash borer (Coleoptera: Buprestidae): influence of size, trap coating, and color.

    PubMed

    Francese, Joseph A; Rietz, Michael L; Mastro, Victor C

    2013-12-01

    Field assays were conducted in southeastern and south-central Michigan in 2011 and 2012 to optimize green and purple multifunnel (Lindgren funnel) traps for use as a survey tool for the emerald ash borer, Agrilus planipennis Fairmaire. Larger sized (12- and 16-unit) multifunnel traps caught more beetles than their smaller-sized (4- and 8-unit) counterparts. Green traps coated with untinted (white) fluon caught almost four times as many adult A. planipennis as Rain-X and tinted (green) fluon-coated traps and almost 33 times more beetles than untreated control traps. Purple multifunnel traps generally caught much lower numbers of A. planipennis adults than green traps, and trap catch on them was not affected by differences in the type of coating applied. However, trap coating was necessary as untreated control purple traps caught significantly less beetles than traps treated with Rain-X and untinted or tinted (purple) fluon. Proportions of male beetles captured were generally much higher on green traps than on purple traps, but sex ratios were not affected by trap coating. In 2012, a new shade of purple plastic, based on a better color match to an attractive purple paint than the previously used purple, was used for trapping assays. When multifunnel traps were treated with fluon, green traps caught more A. planipennis adults than both shades of purple and a prism trap that was manufactured based on the same color match. Trap catch was not affected by diluting the fluon concentration applied to traps to 50% (1:1 mixture in water). At 10%, trap catch was significantly lowered.

  12. Vegetation survey of Pen Branch and Four Mile Creek wetlands

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    One hundred-fifty plots were recently sampled (vegetational sampling study) at the Savannah River Site (SRS). An extensive characterization of the vascular flora, in four predetermined strata (overstory, Understory, shrub layer, and ground cover), was undertaken to determine dominance, co-dominance, and the importance value (I.V.) of each species. These results will be used by the Savannah River Laboratory (SRL) to evaluate the environmental status of Four Mile Creek, Pen Branch, and two upland pine stands. Objectives of this study were to: Describe in detail the plant communities previously mapped with reference to the topography and drainage, including species of plants present:more » Examine the successional trends within each sampling area and describe the extent to which current vegetation communities have resulted from specific earlier vegetation disturbances (e.g., logging and grazing); describe in detail the botanical field techniques used to sample the flora; describe the habitat and location of protected and/or rare species of plants; and collect and prepare plant species as herbarium quality specimens. Sampling was conducted at Four Mile Creek and Pen Branch, and in two upland pine plantations of different age growth.« less

  13. Vegetation survey of Pen Branch and Four Mile Creek wetlands

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-01-01

    One hundred-fifty plots were recently sampled (vegetational sampling study) at the Savannah River Site (SRS). An extensive characterization of the vascular flora, in four predetermined strata (overstory, Understory, shrub layer, and ground cover), was undertaken to determine dominance, co-dominance, and the importance value (I.V.) of each species. These results will be used by the Savannah River Laboratory (SRL) to evaluate the environmental status of Four Mile Creek, Pen Branch, and two upland pine stands. Objectives of this study were to: Describe in detail the plant communities previously mapped with reference to the topography and drainage, including species of plants present:more » Examine the successional trends within each sampling area and describe the extent to which current vegetation communities have resulted from specific earlier vegetation disturbances (e.g., logging and grazing); describe in detail the botanical field techniques used to sample the flora; describe the habitat and location of protected and/or rare species of plants; and collect and prepare plant species as herbarium quality specimens. Sampling was conducted at Four Mile Creek and Pen Branch, and in two upland pine plantations of different age growth.« less

  14. TRAP/SEE Code Users Manual for Predicting Trapped Radiation Environments

    NASA Technical Reports Server (NTRS)

    Armstrong, T. W.; Colborn, B. L.

    2000-01-01

    TRAP/SEE is a PC-based computer code with a user-friendly interface which predicts the ionizing radiation exposure of spacecraft having orbits in the Earth's trapped radiation belts. The code incorporates the standard AP8 and AE8 trapped proton and electron models but also allows application of an improved database interpolation method. The code treats low-Earth as well as highly-elliptical Earth orbits, taking into account trajectory perturbations due to gravitational forces from the Moon and Sun, atmospheric drag, and solar radiation pressure. Orbit-average spectra, peak spectra per orbit, and instantaneous spectra at points along the orbit trajectory are calculated. Described in this report are the features, models, model limitations and uncertainties, input and output descriptions, and example calculations and applications for the TRAP/SEE code.

  15. Application of the CO2-PENS risk analysis tool to the Rock Springs Uplift, Wyoming

    USGS Publications Warehouse

    Stauffer, P.H.; Pawar, R.J.; Surdam, R.C.; Jiao, Z.; Deng, H.; Lettelier, B.C.; Viswanathan, H.S.; Sanzo, D.L.; Keating, G.N.

    2011-01-01

    We describe preliminary application of the CO2-PENS performance and risk analysis tool to a planned geologic CO2 sequestration demonstration project in the Rock Springs Uplift (RSU), located in south western Wyoming. We use data from the RSU to populate CO2-PENS, an evolving system-level modeling tool developed at Los Alamos National Laboratory. This tool has been designed to generate performance and risk assessment calculations for the geologic sequestration of carbon dioxide. Our approach follows Systems Analysis logic and includes estimates of uncertainty in model parameters and Monte-Carlo simulations that lead to probabilistic results. Probabilistic results provide decision makers with a range in the likelihood of different outcomes. Herein we present results from a newly implemented approach in CO 2-PENS that captures site-specific spatially coherent details such as topography on the reservoir/cap-rock interface, changes in saturation and pressure during injection, and dip on overlying aquifers that may be impacted by leakage upward through wellbores and faults. We present simulations of CO 2 injection under different uncertainty distributions for hypothetical leaking wells and faults. Although results are preliminary and to be used only for demonstration of the approach, future results of the risk analysis will form the basis for a discussion on methods to reduce uncertainty in the risk calculations. Additionally, we present ideas on using the model to help locate monitoring equipment to detect potential leaks. By maintaining site-specific details in the CO2-PENS analysis we provide a tool that allows more logical presentations to stakeholders in the region. ?? 2011 Published by Elsevier Ltd.

  16. Using insulin pen needles up to five times does not affect needle tip shape nor increase pain intensity.

    PubMed

    Puder, Jardena J; Atar, Michael; Muller, Beat; Pavan, Marco; Keller, Ulrich

    2005-02-01

    Reusing insulin pen needles could help to reduce the increasing economic burden of diabetes. We tested the hypothesis that reusing insulin pen needles leads to needle tip deformity and increased pain. Three blinded reviewers assessed 123 electron microscope pictures analyzing needle tip deformity of insulin pen needles used up to four times by diabetic subjects and up to five times by blinded non-diabetic volunteers. The estimated frequency of needle use was correlated to the actual number of needle use. Pain intensity and unpleasantness of each injection were measured by a visual analogue scale and their differences analyzed by Kruskal-Wallis analysis of variance. Unused needles could be differentiated visually from used needles. However, there was no correlation between the actual and guessed number of times a needle was used (r = 0.07, P = 0.2). Evaluating all 270 injections, neither pain intensity nor unpleasantness increased with repeated injections of the same needles in people with diabetes (P = 0.1 and 0.96) and in the volunteers (P = 0.63 and 0.92). Using pen needles four to five times does not lead to progressive needle tip deformity and does not increase pain intensity or unpleasantness, but could increase convenience and lead to substantial financial savings in Europe of around EUR 100 million/year.

  17. 47 CFR 69.111 - Tandem-switched transport and tandem charge.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., geographically averaged on a study-area-wide basis, that the incumbent local exchange carrier experiences based... exchange carrier experiences based on the prior year's annual use. Tandem-switched transport transmission..., geographically averaged on a study-area-wide basis, that the incumbent local exchange carrier experiences based...

  18. Density of Trap States and Auger-mediated Electron Trapping in CdTe Quantum-Dot Solids.

    PubMed

    Boehme, Simon C; Azpiroz, Jon Mikel; Aulin, Yaroslav V; Grozema, Ferdinand C; Vanmaekelbergh, Daniël; Siebbeles, Laurens D A; Infante, Ivan; Houtepen, Arjan J

    2015-05-13

    Charge trapping is an ubiquitous process in colloidal quantum-dot solids and a major limitation to the efficiency of quantum dot based devices such as solar cells, LEDs, and thermoelectrics. Although empirical approaches led to a reduction of trapping and thereby efficiency enhancements, the exact chemical nature of the trapping mechanism remains largely unidentified. In this study, we determine the density of trap states in CdTe quantum-dot solids both experimentally, using a combination of electrochemical control of the Fermi level with ultrafast transient absorption and time-resolved photoluminescence spectroscopy, and theoretically, via density functional theory calculations. We find a high density of very efficient electron traps centered ∼0.42 eV above the valence band. Electrochemical filling of these traps increases the electron lifetime and the photoluminescence quantum yield by more than an order of magnitude. The trapping rate constant for holes is an order of magnitude lower that for electrons. These observations can be explained by Auger-mediated electron trapping. From density functional theory calculations we infer that the traps are formed by dicoordinated Te atoms at the quantum dot surface. The combination of our unique experimental determination of the density of trap states with the theoretical modeling of the quantum dot surface allows us to identify the trapping mechanism and chemical reaction at play during charge trapping in these quantum dots.

  19. Tandem catalysis: a new approach to polymers.

    PubMed

    Robert, Carine; Thomas, Christophe M

    2013-12-21

    The creation of polymers by tandem catalysis represents an exciting frontier in materials science. Tandem catalysis is one of the strategies used by Nature for building macromolecules. Living organisms generally synthesize macromolecules by in vivo enzyme-catalyzed chain growth polymerization reactions using activated monomers that have been formed within cells during complex metabolic processes. However, these biological processes rely on highly complex biocatalysts, thus limiting their industrial applications. In order to obtain polymers by tandem catalysis, homogeneous and enzyme catalysts have played a leading role in the last two decades. In the following feature article, we will describe selected published efforts to achieve these research goals.

  20. Simplicity, safety, and acceptability of insulin pen use versus the conventional vial/syringe device in patients with type 1 and type 2 diabetes mellitus in Lebanon

    PubMed Central

    Ramadan, Wijdan H; Khreis, Noura A; Kabbara, Wissam K

    2015-01-01

    Background The aim of the study was to evaluate the simplicity, safety, patients’ preference, and convenience of the administration of insulin using the pen device versus the conventional vial/syringe in patients with diabetes. Methods This observational study was conducted in multiple community pharmacies in Lebanon. The investigators interviewed patients with diabetes using an insulin pen or conventional vial/syringe. A total of 74 questionnaires were filled over a period of 6 months. Answers were entered into the Statistical Package for Social Sciences (SPSS) software and Excel spreadsheet. t-test, logistic regression analysis, and correlation analysis were used in order to analyze the results. Results A higher percentage of patients from the insulin pen users group (95.2%) found the method easy to use as compared to only 46.7% of the insulin conventional users group (P 0.001, relative risk [RR]: 2.041, 95% confidence interval [CI]: 1.178–3.535). Moreover, 61.9% and 26.7% of pen users and conventional users, respectively, could read the scale easily (P 0.037, RR 2.321, 95% CI: 0.940–5.731), while 85.7% of pen users found it more convenient shifting to pen and 86.7% of the conventional users would want to shift to pen if it had the same cost. Pain perception was statistically different between the groups. A much higher percentage (76.2%) of pen users showed no pain during injection compared to only 26.7% of conventional users (P 0.003, RR 2.857, 95% CI: 1.194–6.838). Conclusion The insulin pen was significantly much easier to use and less painful than the conventional vial/syringe. Proper education on the methods of administration/storage and disposal of needles/syringes is needed in both groups. PMID:25848231

  1. Peptide Analysis Using Tandem Mass Spectrometry

    DTIC Science & Technology

    1989-06-01

    to give pyroglutamic acid during storage, eliminating ammonia. It is almost absent in the spectrum of a freshly-prepared sample and is not seen in...USING TANDEM MASS SPECTROMETRY INTRODUCTION S The objective of the project was to determine the complete amino acid sequence of the large polypeptide...Ubiquitin by use of fast atom bombardment (FAB) ionization and tandem mass spectrometry. The peptide containing 76 amino acid residues was available

  2. A versatile strategy for gene trapping and trap conversion in emerging model organisms.

    PubMed

    Kontarakis, Zacharias; Pavlopoulos, Anastasios; Kiupakis, Alexandros; Konstantinides, Nikolaos; Douris, Vassilis; Averof, Michalis

    2011-06-01

    Genetic model organisms such as Drosophila, C. elegans and the mouse provide formidable tools for studying mechanisms of development, physiology and behaviour. Established models alone, however, allow us to survey only a tiny fraction of the morphological and functional diversity present in the animal kingdom. Here, we present iTRAC, a versatile gene-trapping approach that combines the implementation of unbiased genetic screens with the generation of sophisticated genetic tools both in established and emerging model organisms. The approach utilises an exon-trapping transposon vector that carries an integrase docking site, allowing the targeted integration of new constructs into trapped loci. We provide proof of principle for iTRAC in the emerging model crustacean Parhyale hawaiensis: we generate traps that allow specific developmental and physiological processes to be visualised in unparalleled detail, we show that trapped genes can be easily cloned from an unsequenced genome, and we demonstrate targeting of new constructs into a trapped locus. Using this approach, gene traps can serve as platforms for generating diverse reporters, drivers for tissue-specific expression, gene knockdown and other genetic tools not yet imagined.

  3. Arabidopsis ARF-GTP exchange factor, GNOM, mediates transport required for innate immunity and focal accumulation of syntaxin PEN1

    PubMed Central

    Nielsen, Mads Eggert; Feechan, Angela; Böhlenius, Henrik; Ueda, Takashi; Thordal-Christensen, Hans

    2012-01-01

    Penetration resistance to powdery mildew fungi, conferred by localized cell wall appositions (papillae), is one of the best-studied processes in plant innate immunity. The syntaxin PENETRATION (PEN)1 is required for timely appearance of papillae, which contain callose and extracellular membrane material, as well as PEN1 itself. Appearance of membrane material in papillae suggests secretion of exosomes. These are potentially derived from multivesicular bodies (MVBs), supported by our observation that ARA6-labeled organelles assemble at the fungal attack site. However, the trafficking components that mediate delivery of extracellular membrane material are unknown. Here, we show that the delivery is independent of PEN1 function. Instead, we find that application of brefeldin (BF)A blocks the papillary accumulation of GFP-PEN1–labeled extracellular membrane and callose, while impeding penetration resistance. We subsequently provide evidence indicating that the responsible BFA-sensitive ADP ribosylation factor–GTP exchange factor (ARF-GEF) is GNOM. Firstly, analysis of the transheterozygote gnomB4049/emb30-1 (gnomB/E) mutant revealed a delay in papilla formation and reduced penetration resistance. Furthermore, a BFA-resistant version of GNOM restored the BFA-sensitive papillary accumulation of GFP-PEN1 and callose. Our data, therefore, provide a link between GNOM and disease resistance. We suggest that papilla formation requires rapid reorganization of material from the plasma membrane mediated by GNOM. The papilla material is subsequently presumed to be sorted into MVBs and directed to the site of fungal attack, rendering the epidermal plant cell inaccessible for the invading powdery mildew fungus. PMID:22733775

  4. Trap efficiency of reservoirs

    USGS Publications Warehouse

    Brune, Gunnar M.

    1953-01-01

    Forty-four records of reservoir trap efficiency and the factors affecting trap efficiency are analyzed. The capacity-inflow (C/I) ratio is found to offer a much closer correlation with trap efficiency than the capacity-watershed (C/W) ratio heretofore widely used. It appears likely from the cases studied that accurate timing of venting or sluicing operations to intercept gravity underflows can treble or quadruple the amount of sediment discharged from a reservoir. Desilting basins, because of their shape and method of operation, may have trap efficiencies above 90 pct even with very low C/I ratios.Semi-dry reservoirs with high C/I ratios, like John Martin Reservoir, may have trap efficiencies as low as 60 pct. Truly “dry” reservoirs, such as those in the Miami Conservancy District, probably have trap efficiencies in the 10 to 40 pct range, depending upon C/I ratio

  5. A horizontally polarizing liquid trap enhances the tabanid-capturing efficiency of the classic canopy trap.

    PubMed

    Egri, Á; Blahó, M; Száz, D; Kriska, G; Majer, J; Herczeg, T; Gyurkovszky, M; Farkas, R; Horváth, G

    2013-12-01

    Host-seeking female tabanid flies, that need mammalian blood for the development of their eggs, can be captured by the classic canopy trap with an elevated shiny black sphere as a luring visual target. The design of more efficient tabanid traps is important for stock-breeders to control tabanids, since these blood-sucking insects can cause severe problems for livestock, especially for horse- and cattle-keepers: reduced meat/milk production in cattle farms, horses cannot be ridden, decreased quality of hides due to biting scars. We show here that male and female tabanids can be caught by a novel, weather-proof liquid-filled black tray laid on the ground, because the strongly and horizontally polarized light reflected from the black liquid surface attracts water-seeking polarotactic tabanids. We performed field experiments to reveal the ideal elevation of the liquid trap and to compare the tabanid-capturing efficiency of three different traps: (1) the classic canopy trap, (2) the new polarization liquid trap, and (3) the combination of the two traps. In field tests, we showed that the combined trap captures 2.4-8.2 times more tabanids than the canopy trap alone. The reason for the larger efficiency of the combined trap is that it captures simultaneously the host-seeking female and the water-seeking male and female tabanids. We suggest supplementing the traditional canopy trap with the new liquid trap in order to enhance the tabanid-capturing efficiency.

  6. Surface-electrode point Paul trap

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Tony Hyun; Herskind, Peter F.; Chuang, Isaac L.

    2010-10-15

    We present a model as well as experimental results for a surface electrode radiofrequency Paul trap that has a circular electrode geometry well suited for trapping single ions and two-dimensional planar ion crystals. The trap design is compatible with microfabrication and offers a simple method by which the height of the trapped ions above the surface may be changed in situ. We demonstrate trapping of single {sup 88}Sr{sup +} ions over an ion height range of 200-1000 {mu}m for several hours under Doppler laser cooling and use these to characterize the trap, finding good agreement with our model.

  7. 7. BUILDING 604F, INTERIOR OF BULL PEN SHOWING TESTING STAND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. BUILDING 604-F, INTERIOR OF BULL PEN SHOWING TESTING STAND AND HEAVY WOOD LINING ON CONCRETE WALLS. STEEL PLATE ABOVE TEST STAND DEFLECTS SHRAPNEL, SCREEN FURTHER HELPS TO CONTAIN PARTICLES. ONLY SMALL EXPLOSIVES WERE TESTED HERE (GRENADES, MINES, BOMB FUZES, ETC.). - Picatinny Arsenal, 600 Area, Test Areas District, State Route 15 near I-80, Dover, Morris County, NJ

  8. Microfabricated cylindrical ion trap

    DOEpatents

    Blain, Matthew G.

    2005-03-22

    A microscale cylindrical ion trap, having an inner radius of order one micron, can be fabricated using surface micromachining techniques and materials known to the integrated circuits manufacturing and microelectromechanical systems industries. Micromachining methods enable batch fabrication, reduced manufacturing costs, dimensional and positional precision, and monolithic integration of massive arrays of ion traps with microscale ion generation and detection devices. Massive arraying enables the microscale cylindrical ion trap to retain the resolution, sensitivity, and mass range advantages necessary for high chemical selectivity. The microscale CIT has a reduced ion mean free path, allowing operation at higher pressures with less expensive and less bulky vacuum pumping system, and with lower battery power than conventional- and miniature-sized ion traps. The reduced electrode voltage enables integration of the microscale cylindrical ion trap with on-chip integrated circuit-based rf operation and detection electronics (i.e., cell phone electronics). Therefore, the full performance advantages of microscale cylindrical ion traps can be realized in truly field portable, handheld microanalysis systems.

  9. Ecological and evolutionary traps

    USGS Publications Warehouse

    Schlaepfer, Martin A.; Runge, M.C.; Sherman, P.W.

    2002-01-01

    Organisms often rely on environmental cues to make behavioral and life-history decisions. However, in environments that have been altered suddenly by humans, formerly reliable cues might no longer be associated with adaptive outcomes. In such cases, organisms can become 'trapped' by their evolutionary responses to the cues and experience reduced survival or reproduction. Ecological traps occur when organisms make poor habitat choices based on cues that correlated formerly with habitat quality. Ecological traps are part of a broader phenomenon, evolutionary traps, involving a dissociation between cues that organisms use to make any behavioral or life-history decision and outcomes normally associated with that decision. A trap can lead to extinction if a population falls below a critical size threshold before adaptation to the novel environment occurs. Conservation and management protocols must be designed in light of, rather than in spite of, the behavioral mechanisms and evolutionary history of populations and species to avoid 'trapping' them.

  10. [Trapping techniques for Solenopsis invicta].

    PubMed

    Liang, Xiao-song; Zhang, Qiang; Zhuang, Yiong-lin; Li, Gui-wen; Ji, Lin-peng; Wang, Jian-guo; Dai, Hua-guo

    2007-06-01

    A field study was made to investigate the trapping effects of different attractants, traps, and wind directions on Solenopsis invicta. The results showed that among the test attractants, TB1 (50 g fishmeal, 40 g peptone, 10 ml 10% sucrose water solution and 20 ml soybean oil) had the best effect, followed by TB2 (ham), TB6 (100 g cornmeal and 20 ml soybean oil) and TB4 (10 ml 10% sucrose water solution, 100 g sugarcane powder and 20 ml soybean oil), with a mean capture efficiency being 77.6, 58.7, 29 and 7.7 individuals per trap, respectively. No S. invicta was trapped with TB3 (10 ml 10% sucrose water solution, 100 g cornmeal and 20 ml soybean oil) and TB5 (honey). Tube trap was superior to dish trap, with a trapping efficiency of 75.2 and 35 individuals per trap, respectively. The attractants had better effects in leeward than in windward.

  11. NeuroPigPen: A Scalable Toolkit for Processing Electrophysiological Signal Data in Neuroscience Applications Using Apache Pig

    PubMed Central

    Sahoo, Satya S.; Wei, Annan; Valdez, Joshua; Wang, Li; Zonjy, Bilal; Tatsuoka, Curtis; Loparo, Kenneth A.; Lhatoo, Samden D.

    2016-01-01

    The recent advances in neurological imaging and sensing technologies have led to rapid increase in the volume, rate of data generation, and variety of neuroscience data. This “neuroscience Big data” represents a significant opportunity for the biomedical research community to design experiments using data with greater timescale, large number of attributes, and statistically significant data size. The results from these new data-driven research techniques can advance our understanding of complex neurological disorders, help model long-term effects of brain injuries, and provide new insights into dynamics of brain networks. However, many existing neuroinformatics data processing and analysis tools were not built to manage large volume of data, which makes it difficult for researchers to effectively leverage this available data to advance their research. We introduce a new toolkit called NeuroPigPen that was developed using Apache Hadoop and Pig data flow language to address the challenges posed by large-scale electrophysiological signal data. NeuroPigPen is a modular toolkit that can process large volumes of electrophysiological signal data, such as Electroencephalogram (EEG), Electrocardiogram (ECG), and blood oxygen levels (SpO2), using a new distributed storage model called Cloudwave Signal Format (CSF) that supports easy partitioning and storage of signal data on commodity hardware. NeuroPigPen was developed with three design principles: (a) Scalability—the ability to efficiently process increasing volumes of data; (b) Adaptability—the toolkit can be deployed across different computing configurations; and (c) Ease of programming—the toolkit can be easily used to compose multi-step data processing pipelines using high-level programming constructs. The NeuroPigPen toolkit was evaluated using 750 GB of electrophysiological signal data over a variety of Hadoop cluster configurations ranging from 3 to 30 Data nodes. The evaluation results demonstrate that

  12. TRedD—A database for tandem repeats over the edit distance

    PubMed Central

    Sokol, Dina; Atagun, Firat

    2010-01-01

    A ‘tandem repeat’ in DNA is a sequence of two or more contiguous, approximate copies of a pattern of nucleotides. Tandem repeats are common in the genomes of both eukaryotic and prokaryotic organisms. They are significant markers for human identity testing, disease diagnosis, sequence homology and population studies. In this article, we describe a new database, TRedD, which contains the tandem repeats found in the human genome. The database is publicly available online, and the software for locating the repeats is also freely available. The definition of tandem repeats used by TRedD is a new and innovative definition based upon the concept of ‘evolutive tandem repeats’. In addition, we have developed a tool, called TandemGraph, to graphically depict the repeats occurring in a sequence. This tool can be coupled with any repeat finding software, and it should greatly facilitate analysis of results. Database URL: http://tandem.sci.brooklyn.cuny.edu/ PMID:20624712

  13. Effect of bait quantity and trap color on the trapping efficacy of the pheromone trap for the red palm weevil, Rhynchophorus ferrugineus.

    PubMed

    Abuagla, Abdullah Mohamed; Al-Deeb, Mohammad Ali

    2012-01-01

    The red palm weevil, Rhynchophorus ferrugineus (Olivier) (Curculionidae: Coleoptera), is not native to the United Arab Emirates (UAE). Since its arrival in 1985, it has been causing major damage to date palm trees. A primary control strategy has been the use of pheromone baited traps. The objectives of this study were to determine the quantity of bait, and the best trap color, to obtain the maximum catch of R. ferrugineus under field conditions in the UAE. Traps with 100, 300, or 500 g of dates as bait collected the same number of R. ferrugineus adults. Captures in black traps were significantly higher than captures in red, yellow, or white traps. Thus, using a black pheromone trap containing 100 g of dates can significantly enhance R. ferrugineus control efforts, and can help considerably in reducing the red palm weevil's deleterious impact on date palm production in UAE.

  14. Evaluation of trapping-web designs

    USGS Publications Warehouse

    Lukacs, P.M.; Anderson, D.R.; Burnham, K.P.

    2005-01-01

    The trapping web is a method for estimating the density and abundance of animal populations. A Monte Carlo simulation study is performed to explore performance of the trapping web for estimating animal density under a variety of web designs and animal behaviours. The trapping performs well when animals have home ranges, even if the home ranges are large relative to trap spacing. Webs should contain at least 90 traps. Trapping should continue for 5-7 occasions. Movement rates have little impact on density estimates when animals are confined to home ranges. Estimation is poor when animals do not have home ranges and movement rates are rapid. The trapping web is useful for estimating the density of animals that are hard to detect and occur at potentially low densities. ?? CSIRO 2005.

  15. Electrospray-assisted laser desorption/ionization and tandem mass spectrometry of peptides and proteins.

    PubMed

    Peng, Ivory X; Shiea, Jentaie; Ogorzalek Loo, Rachel R; Loo, Joseph A

    2007-01-01

    We have constructed an electrospray-assisted laser desorption/ionization (ELDI) source which utilizes a nitrogen laser pulse to desorb intact molecules from matrix-containing sample solution droplets, followed by electrospray ionization (ESI) post-ionization. The ELDI source is coupled to a quadrupole ion trap mass spectrometer and allows sampling under ambient conditions. Preliminary data showed that ELDI produces ESI-like multiply charged peptides and proteins up to 29 kDa carbonic anhydrase and 66 kDa bovine albumin from single-protein solutions, as well as from complex digest mixtures. The generated multiply charged polypeptides enable efficient tandem mass spectrometric (MS/MS)-based peptide sequencing. ELDI-MS/MS of protein digests and small intact proteins was performed both by collisionally activated dissociation (CAD) and by nozzle-skimmer dissociation (NSD). ELDI-MS/MS may be a useful tool for protein sequencing analysis and top-down proteomics study, and may complement matrix-assisted laser desorption/ionization (MALDI)-based measurements. Copyright (c) 2007 John Wiley & Sons, Ltd.

  16. PTGBase: an integrated database to study tandem duplicated genes in plants.

    PubMed

    Yu, Jingyin; Ke, Tao; Tehrim, Sadia; Sun, Fengming; Liao, Boshou; Hua, Wei

    2015-01-01

    Tandem duplication is a wide-spread phenomenon in plant genomes and plays significant roles in evolution and adaptation to changing environments. Tandem duplicated genes related to certain functions will lead to the expansion of gene families and bring increase of gene dosage in the form of gene cluster arrays. Many tandem duplication events have been studied in plant genomes; yet, there is a surprising shortage of efforts to systematically present the integration of large amounts of information about publicly deposited tandem duplicated gene data across the plant kingdom. To address this shortcoming, we developed the first plant tandem duplicated genes database, PTGBase. It delivers the most comprehensive resource available to date, spanning 39 plant genomes, including model species and newly sequenced species alike. Across these genomes, 54 130 tandem duplicated gene clusters (129 652 genes) are presented in the database. Each tandem array, as well as its member genes, is characterized in complete detail. Tandem duplicated genes in PTGBase can be explored through browsing or searching by identifiers or keywords of functional annotation and sequence similarity. Users can download tandem duplicated gene arrays easily to any scale, up to the complete annotation data set for an entire plant genome. PTGBase will be updated regularly with newly sequenced plant species as they become available. © The Author(s) 2015. Published by Oxford University Press.

  17. Hybrid Tandem Solar Cells | Photovoltaic Research | NREL

    Science.gov Websites

    Hybrid Tandem Solar Cells Hybrid Tandem Solar Cells To achieve aggressive cost reductions in photovoltaics (PV) beyond the 6¢/kWh SunShot Initiative 2020 goal, module efficiency must be increased beyond on a silicon platform and that aim to provide viable prototypes for commercialization. PV Research

  18. Monolithic Parallel Tandem Organic Photovoltaic Cell with Transparent Carbon Nanotube Interlayer

    NASA Technical Reports Server (NTRS)

    Tanaka, S.; Mielczarek, K.; Ovalle-Robles, R.; Wang, B.; Hsu, D.; Zakhidov, A. A.

    2009-01-01

    We demonstrate an organic photovoltaic cell with a monolithic tandem structure in parallel connection. Transparent multiwalled carbon nanotube sheets are used as an interlayer anode electrode for this parallel tandem. The characteristics of front and back cells are measured independently. The short circuit current density of the parallel tandem cell is larger than the currents of each individual cell. The wavelength dependence of photocurrent for the parallel tandem cell shows the superposition spectrum of the two spectral sensitivities of the front and back cells. The monolithic three-electrode photovoltaic cell indeed operates as a parallel tandem with improved efficiency.

  19. Isotopologue Distributions of Peptide Product Ions by Tandem Mass Spectrometry: Quantitation of Low Levels of Deuterium Incorporation1

    PubMed Central

    Wang, Benlian; Sun, Gang; Anderson, David R.; Jia, Minghong; Previs, Stephen; Anderson, Vernon E.

    2007-01-01

    Protonated molecular peptide ions and their product ions generated by tandem mass spectrometry appear as isotopologue clusters due to the natural isotopic variations of carbon, hydrogen, nitrogen, oxygen and sulfur. Quantitation of the isotopic composition of peptides can be employed in experiments involving isotope effects, isotope exchange, isotopic labeling by chemical reactions, and studies of metabolism by stable isotope incorporation. Both ion trap and quadrupole-time of flight mass spectrometry are shown to be capable of determining the isotopic composition of peptide product ions obtained by tandem mass spectrometry with both precision and accuracy. Tandem mass spectra obtained in profile-mode of clusters of isotopologue ions are fit by non-linear least squares to a series of Gaussian peaks (described in the accompanying manuscript) which quantify the Mn/M0 values which define the isotopologue distribution (ID). To determine the isotopic composition of product ions from their ID, a new algorithm that predicts the Mn/M0 ratios is developed which obviates the need to determine the intensity of all of the ions of an ID. Consequently a precise and accurate determination of the isotopic composition a product ion may be obtained from only the initial values of the ID, however the entire isotopologue cluster must be isolated prior to fragmentation. Following optimization of the molecular ion isolation width, fragmentation energy and detector sensitivity, the presence of isotopic excess (2H, 13C, 15N, 18O) is readily determined within 1%. The ability to determine the isotopic composition of sequential product ions permits the isotopic composition of individual amino acid residues in the precursor ion to be determined. PMID:17559791

  20. ECCENTRICITY TRAP: TRAPPING OF RESONANTLY INTERACTING PLANETS NEAR THE DISK INNER EDGE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ogihara, Masahiro; Ida, Shigeru; Duncan, Martin J., E-mail: ogihara@geo.titech.ac.j, E-mail: ida@geo.titech.ac.j, E-mail: duncan@astro.queensu.c

    2010-10-01

    Using orbital integration and analytical arguments, we have found a new mechanism (an 'eccentricity trap') to halt type I migration of planets near the inner edge of a protoplanetary disk. Because asymmetric eccentricity damping due to disk-planet interaction on the innermost planet at the disk edge plays a crucial role in the trap, this mechanism requires continuous eccentricity excitation and hence works for a resonantly interacting convoy of planets. This trap is so strong that the edge torque exerted on the innermost planet can completely halt type I migrations of many outer planets through mutual resonant perturbations. Consequently, the convoymore » stays outside the disk edge, as a whole. We have derived a semi-analytical formula for the condition for the eccentricity trap and predict how many planets are likely to be trapped. We found that several planets or more should be trapped by this mechanism in protoplanetary disks that have cavities. It can be responsible for the formation of non-resonant, multiple, close-in super-Earth systems extending beyond 0.1 AU. Such systems are being revealed by radial velocity observations to be quite common around solar-type stars.« less

  1. Secretion Trap Tagging of Secreted and Membrane-Spanning Proteins Using Arabidopsis Gene Traps

    Treesearch

    Andrew T. Groover; Joseph R. Fontana; Juana M. Arroyo; Cristina Yordan; W. Richard McCombie; Robert A. Martienssen

    2003-01-01

    Secreted and membrane-spanning proteins play fundamental roles in plant development but pose challenges for genetic identification and characterization. We describe a "secretion trap" screen for gene trap insertions in genes encoding proteins routed through the secretory pathway. The gene trap transposon encodes a ß-glucuronidase reporter enzyme...

  2. Usability of devices for self-injection: results of a formative study on a new disposable pen injector.

    PubMed

    Lange, Jakob; Richard, Philipp; Bradley, Nick

    2014-01-01

    This article presents a late-stage formative usability study of a pen-injector platform device. Such devices are used for the subcutaneous delivery of biopharmaceuticals, primarily for self-administration by the patient. The study was conducted with a broad user population, defined to represent user characteristics across a range of indications. The goals of the study were to confirm that the pen could be used without recurring patterns of use errors leading to hazardous situations, to evaluate the comprehension of the instructions for use (IFU), and to determine if training is necessary. In the study, a total of 36 participants in six groups (health care providers, caregivers, adolescents, diabetics with retinopathy, diabetics with neuropathy, and patients with arthritis) each read the IFU, prepared the device, and performed two simulated injections into an injection pad. Any use errors, near misses, or deviations from the IFU procedure were recorded. The overall success rate (injection completed by the participant without need for assistance) was 94% for the first and 100% for the second injection. Ninety-two percent of the participants reported that they felt confident using the device, 100% found the IFU helpful, and 75% found the device positively comfortable to use. Overall, a total average of 3.35 deviations and errors per user and injection were recorded (there were no near misses). Subtracting the errors without any potential for negative consequences for the injection or the user (trivial deviations), as well as those related to attaching and removing the pen needle (independent of the design of the pen itself), led to an average of 1.31 potentially relevant deviations per user and injection. It was concluded that the pen injector together with the IFU could be safely and efficiently used by all user groups without any training, and thus that the device and IFU in their current form are well suited for use in a range of specific applications.

  3. Analysis on composition and inclusions of ballpoint pen tip steel

    NASA Astrophysics Data System (ADS)

    Yang, Qian-kun; Shen, Ping; Zhang, Dong; Wu, Yan-xin; Fu, Jian-xun

    2018-04-01

    Ballpoint pen tip steel, a super free-cutting stainless steel, exhibits excellent corrosion resistance and good machining properties. In this study, inductively coupled plasma spectroscopy, metallographic microscopy, and scanning electron microscopy were used to determine the elemental contents in five ballpoint pen tips and their components, morphologies, and inclusion distributions. The results showed that the steels were all S-Pb-Te super free-cutting ferritic stainless steel. The free-cutting phases in the steels were mainly MnS, Pb, and small amounts of PbTe. MnS inclusions were in the form of chain distributions, and the aspect ratio of each size inclusion in the chain was small. The stress concentration effect could substantially reduce the cutting force when the material was machined. Some of the Pb was distributed evenly in the steel matrix as fine particles (1-2 μm), and the rest of the Pb was distributed at the middle or at both ends of the MnS inclusions. The Pb plays a role in lubrication and melting embrittlement, which substantially increases the cutting performance. PbTe was also usually distributed in the middle and at both ends of the MnS inclusions, and Te could convert the sulfides into spindles, thereby improving the cutting performance of the steel.

  4. Inverted Three-Junction Tandem Thermophotovoltaic Modules

    NASA Technical Reports Server (NTRS)

    Wojtczuk, Steven

    2012-01-01

    An InGaAs-based three-junction (3J) tandem thermophotovoltaic (TPV) cell has been investigated to utilize more of the blackbody spectrum (from a 1,100 C general purpose heat source GPHS) efficiently. The tandem consists of three vertically stacked subcells, a 0.74-eV InGaAs cell, a 0.6- eV InGaAs cell, and a 0.55-eV InGaAs cell, as well as two interconnecting tunnel junctions. A greater than 20% TPV system efficiency was achieved by another group with a 1,040 C blackbody using a single-bandgap 0.6- eV InGaAs cell MIM (monolithic interconnected module) (30 lateral junctions) that delivered about 12 V/30 or 0.4 V/junction. It is expected that a three-bandgap tandem MIM will eventually have about 3 this voltage (1.15 V) and about half the current. A 4 A/cm2 would be generated by a single-bandgap 0.6-V InGaAs MIM, as opposed to the 2 A/cm2 available from the same spectrum when split among the three series-connected junctions in the tandem stack. This would then be about a 50% increase (3xVoc, 0.5xIsc) in output power if the proposed tandem replaced the single- bandgap MIM. The advantage of the innovation, if successful, would be a 50% increase in power conversion efficiency from radioisotope heat sources using existing thermophotovoltaics. Up to 50% more power would be generated for radioisotope GPHS deep space missions. This type of InGaAs multijunction stack could be used with terrestrial concentrator solar cells to increase efficiency from 41 to 45% or more.

  5. Students' Attention When Using Touchscreens and Pen Tablets in a Mathematics Classroom

    ERIC Educational Resources Information Center

    Chen, Cheng-Huan; Chiu, Chiung-Hui; Lin, Chia-Ping; Chou, Ying-Chun

    2017-01-01

    Aim/Purpose: The present study investigated and compared students' attention in terms of time-on-task and number of distractors between using a touchscreen and a pen tablet in mathematical problem solving activities with virtual manipulatives. Background: Although there is an increasing use of these input devices in educational practice, little…

  6. Engaging Students with Pre-Recorded "Live" Reflections on Problem-Solving with "Livescribe" Pens

    ERIC Educational Resources Information Center

    Hickman, Mike

    2013-01-01

    This pilot study, involving PGCE primary student teachers, applies "Livescribe" pen technology to facilitate individual and group reflection on collaborative mathematical problem solving (Hickman 2011). The research question was: How does thinking aloud, supported by digital audio recording, support student teachers' understanding of…

  7. Effects of corn processing, particle size, and diet form on performance of calves in bedded pens.

    PubMed

    Bateman, H G; Hill, T M; Aldrich, J M; Schlotterbeck, R L

    2009-02-01

    In a series of 5 trials, Holstein calves from zero to 12 wk old were housed in pens bedded with straw and fed diets to evaluate physical form of starters containing different processed corn on calf performance. Starters were formulated to have similar ingredient and nutrient compositions. Calves, initially less than 1 wk old, were housed in individual pens through 8 wk and weaned at 6 wk in trial 1 and at 4 wk in trials 2 and 3. In trials 4 and 5, calves initially 8 wk old were housed in group pens (6 calves/pen) from 8 to 12 wk. Trial 1 compared feeding calves a pelleted versus textured starter. Trial 2 compared feeding calves a textured starter versus feeding half meal starter with half textured starter. Trial 3 compared feeding calves textured starters containing whole, steam-flaked, or dry rolled corn. Trial 4 compared feeding calves textured starters containing steam-flaked versus dry rolled corn. Trial 5 compared feeding calves textured starters containing whole or dry rolled corn. Measurements included average daily gain (ADG), starter intake, feed efficiency, hip width change, body condition score change, fecal scores, and medical treatments. Physical form of starter feed did not affect any measurements in trials 1, 3, 4, and 5. In trial 2, calves fed starters manufactured with large amounts of fines had 11% less feed intake and 6% slower ADG than calves fed a textured starter. When starters contained similar ingredient and nutrient contents, manufacturing processes did not affect calf performance unless the diet contained a significant amount of fines, which reduced intake and ADG.

  8. Linear Ion Traps in Space: The Mars Organic Molecule Analyzer (MOMA) Instrument and Beyond

    NASA Astrophysics Data System (ADS)

    Arevalo, Ricardo; Brinckerhoff, William; Mahaffy, Paul; van Amerom, Friso; Danell, Ryan; Pinnick, Veronica; Li, Xiang; Hovmand, Lars; Getty, Stephanie; Grubisic, Andrej; Goesmann, Fred; Cottin, Hervé

    2015-11-01

    Historically, quadrupole mass spectrometer (QMS) instruments have been used to explore a wide survey of planetary targets in our solar system, from Venus (Pioneer Venus) to Saturn (Cassini-Huygens). However, linear ion trap (LIT) mass spectrometers have found a niche as smaller, versatile alternatives to traditional quadrupole analyzers.The core astrobiological experiment of ESA’s ExoMars Program is the Mars Organic Molecule Analyzer (MOMA) onboard the ExoMars 2018 rover. The MOMA instrument is centered on a linear (or 2-D) ion trap mass spectrometer. As opposed to 3-D traps, LIT-based instruments accommodate two symmetrical ion injection pathways, enabling two complementary ion sources to be used. In the case of MOMA, these two analytical approaches are laser desorption mass spectrometry (LDMS) at Mars ambient pressures, and traditional gas chromatography mass spectrometry (GCMS). The LIT analyzer employed by MOMA also offers: higher ion capacity compared to a 3-D trap of the same volume; redundant detection subassemblies for extended lifetime; and, a link to heritage QMS designs and assembly logistics. The MOMA engineering test unit (ETU) has demonstrated the detection of organics in the presence of wt.%-levels of perchlorate, effective ion enhancement via stored waveform inverse Fourier transform (SWIFT), and derivation of structural information through tandem mass spectrometry (MS/MS).A more progressive linear ion trap mass spectrometer (LITMS), funded by the NASA ROSES MatISSE Program, is being developed at NASA GSFC and promises to augment the capabilities of the MOMA instrument by way of: an expanded mass range (i.e., 20 - 2000 Da); detection of both positive and negative ions; spatially resolved (<1 mm) characterization of individual rock core layers; and, evolved gas analysis and GCMS with pyrolysis up to 1300° C (enabling breakdown of refractory phases). The Advanced Resolution Organic Molecule Analyzer (AROMA) instrument, being developed through NASA

  9. Performance of a tandem-rotor/tandem-stator conical-flow compressor designed for a pressure ratio of 3

    NASA Technical Reports Server (NTRS)

    Wood, J. R.; Owen, A. K.; Schumann, L. F.

    1982-01-01

    A conical-flow compressor stage with a large radius change through the rotor was tested at three values of rotor tip clearance. The stage had a tandem rotor and a tandem stator. Peak efficiency at design speed was 0.774 at a pressure ratio of 2.613. The rotor was tested without the stator, and detailed survey data were obtained for each rotor blade row. Overall peak rotor efficiency was 0.871 at a pressure ratio of 2.952.

  10. Vibrios from Fish Pen Slime Which Mimic Escherichia coli on Violet Red Bile Agar

    PubMed Central

    Rosen, A.; Levin, R. E.

    1970-01-01

    Organisms from fish pen slime which mimicked coliforms and Escherichia coli on Violet Red Bile Agar were identified as members of the genus Vibrio on the basis of metabolic and morphological characteristics. Images PMID:4195607

  11. A tandem-based compact dual-energy gamma generator.

    PubMed

    Persaud, A; Kwan, J W; Leitner, M; Leung, K-N; Ludewigt, B; Tanaka, N; Waldron, W; Wilde, S; Antolak, A J; Morse, D H; Raber, T

    2010-02-01

    A dual-energy tandem-type gamma generator has been developed at E. O. Lawrence Berkeley National Laboratory and Sandia National Laboratories. The tandem accelerator geometry allows higher energy nuclear reactions to be reached, thereby allowing more flexible generation of MeV-energy gammas for active interrogation applications. Both positively charged ions and atoms of hydrogen are created from negative ions via a gas stripper. In this paper, we show first results of the working tandem-based gamma generator and that a gas stripper can be utilized in a compact source design. Preliminary results of monoenergetic gamma production are shown.

  12. Using the PEN-3 Model to Plan Culturally Competent Domestic Violence Intervention and Prevention Services in Chinese American and Immigrant Communities

    ERIC Educational Resources Information Center

    Yick, Alice G.; Oomen-Early, Jody

    2009-01-01

    Purpose: The purpose of this article is two-fold. First, it applies the PEN-3 model to the topic of domestic violence within the Chinese American and Chinese immigrant community. The PEN-3 model was developed by Collins Airhihenbuwa, and it focuses on placing culture at the forefront of health promotion. It consists of three dimensions: cultural…

  13. Advances in the use of trapping systems for Rhynchophorus ferrugineus (Coleoptera: Curculionidae): traps and attractants.

    PubMed

    Vacas, S; Primo, J; Navarro-Llopis, V

    2013-08-01

    Given the social importance related to the red palm weevil, Rhynchophorus ferrugineus Olivier (Coleoptera: Curculionidae), efforts are being made to develop new control methods, such as the deployment of trapping systems. In this work, the efficacy of a new black pyramidal trap design (Picusan) has been verified in comparison with white and black buckets. In addition, the attractant and synergistic effect of ethyl acetate (EtAc) at different release levels has been evaluated under field conditions. The results show that Picusan traps captured 45% more weevils than bucket-type traps, offering significantly better trapping efficacy. The addition of water to traps baited with palm tissues was found to be essential, with catches increasing more than threefold compared with dry traps. EtAc alone does not offer attractant power under field conditions, and the release levels from 57 mg/d to 1 g/d have no synergistic effect with ferrugineol. Furthermore, significantly fewer females were captured when EtAc was released at 2 g/d. The implications of using EtAc dispensers in trapping systems are discussed.

  14. Solar-to-Chemical Energy Conversion with Photoelectrochemical Tandem Cells.

    PubMed

    Sivula, Kevin

    2013-01-01

    Efficiently and inexpensively converting solar energy into chemical fuels is an important goal towards a sustainable energy economy. An integrated tandem cell approach could reasonably convert over 20% of the sun's energy directly into chemical fuels like H2 via water splitting. Many different systems have been investigated using various combinations of photovoltaic cells and photoelectrodes, but in order to be economically competitive with the production of H2 from fossil fuels, a practical water splitting tandem cell must optimize cost, longevity and performance. In this short review, the practical aspects of solar fuel production are considered from the perspective of a semiconductor-based tandem cell and the latest advances with a very promising technology - metal oxide photoelectrochemical tandem cells - are presented.

  15. Stimulated Motion Suppression (STMS): a New Approach to Break the Resolution Barrier for Ion Trap Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Zhou, Xiaoyu; Liu, Xinwei; Chiang, Spencer; Cao, Wenbo; Li, Ming; Ouyang, Zheng

    2018-05-01

    Ion trap is an excellent platform to perform tandem mass spectrometry (MS/MS), but has an intrinsic drawback in resolving power. Using ion resonant ejection as an example, the resolution degradation can be largely attributed to the broadening of the resonant frequency band (RFB) between ion motion and driving alternative-current (AC). To solve this problem, stimulated motion suppression (STMS) was developed. The key idea of STMS is the use of two suppression alternative-current (SAC) signals, which both have reversed initial phases to the main AC. The SACs can block the unexpected sideband ion resonances (or ejections), therefore playing a key role in sharpening the RFB. The proof-of-concept has been demonstrated through ion trajectory simulations and validated experimentally. STMS provides a new and versatile means for the improvement of the ion trap resolution, which for a long time has reached the bottleneck through conventional methods, e.g., increasing the radio-frequency (RF) voltage and decreasing the mass scan rate. At the end, it is worth noting that the idea of STMS is very general and principally can be applied in any RF device for the purposes of high-resolution mass analysis and ion isolation.

  16. Combined acoustic and optical trapping

    PubMed Central

    Thalhammer, G.; Steiger, R.; Meinschad, M.; Hill, M.; Bernet, S.; Ritsch-Marte, M.

    2011-01-01

    Combining several methods for contact free micro-manipulation of small particles such as cells or micro-organisms provides the advantages of each method in a single setup. Optical tweezers, which employ focused laser beams, offer very precise and selective handling of single particles. On the other hand, acoustic trapping with wavelengths of about 1 mm allows the simultaneous trapping of many, comparatively large particles. With conventional approaches it is difficult to fully employ the strengths of each method due to the different experimental requirements. Here we present the combined optical and acoustic trapping of motile micro-organisms in a microfluidic environment, utilizing optical macro-tweezers, which offer a large field of view and working distance of several millimeters and therefore match the typical range of acoustic trapping. We characterize the acoustic trapping forces with the help of optically trapped particles and present several applications of the combined optical and acoustic trapping, such as manipulation of large (75 μm) particles and active particle sorting. PMID:22025990

  17. Host cell entry of powdery mildew is correlated with endosomal transport of antagonistically acting VvPEN1 and VvMLO to the papilla.

    PubMed

    Feechan, A; Jermakow, A M; Ivancevic, A; Godfrey, D; Pak, H; Panstruga, R; Dry, I B

    2013-10-01

    Challenge by a nonadapted powdery mildew fungal pathogen leads to the formation of a local cell-wall apposition (papilla) beneath the point of attempted penetration. Several plasma membrane (PM) proteins with opposing roles in powdery mildew infection, including Arabidopsis thaliana PENETRATION1 (PEN1) and barley (Hordeum vulgare) MILDEW RESISTANCE LOCUS O (MLO), are localized to the site of powdery mildew attack. PEN1 contributes to penetration resistance to nonadapted powdery mildews, whereas MLO is a susceptibility factor required by adapted powdery mildew pathogens for host cell entry. Our previous studies have demonstrated that the vesicle and endosomal trafficking inhibitors, brefeldin A and wortmannin, have opposite effects on the penetration rates of adapted and nonadapted powdery mildews on grapevine. These findings prompted us to study the pathogen-induced intracellular trafficking of grapevine variants of MLO and PEN1. We first identified grapevine (Vitis vinifera) VvPEN1 and VvMLO orthologs that rescue Arabidopsis Atpen1 and Atmlo2 mlo6 mlo12 null mutants, respectively. By using endomembrane trafficking inhibitors in combination with fluorescence microscopy, we demonstrate that VvMLO3/VvMLO4 and VvPEN1 are co-trafficked together from the PM to the site of powdery mildew challenge. This focal accumulation of VvMLO3/VvMLO4 and VvPEN1 to the site of attack seems to be required for their opposing functions during powdery mildew attack, because their subcellular localization is correlated with the outcome of attempted powdery mildew penetration.

  18. Penning Effects in High-Pressure Discharge of the Plasma Display Panel

    NASA Astrophysics Data System (ADS)

    Kim, S. S.; Choi, E. H.; Uhm, H. S.

    2001-10-01

    The plasma display panel is operated with high-pressure gas, for which the breakdown voltage reduction may be accomplished by mixing a small amount of xenon with neon gas. The UV light emitted from xenon discharge plasma is converted into fluorescent light, providing TV images. A recent theoretical calculation indicates that the breakdown voltage is significantly reduced for the mixed gas due to collisional frequency decrease. It is easy to ionize xenon atoms with low ionization energy. The electrons can also easily get their kinetic energy in neon gas mixed with xenon atoms, thereby reducing their collisional cross section and ionizing xenon atoms. However, previous study indicates that the breakdown voltage can be further reduced by the Penning effects, which has been mostly studied in a low pressure discharge. Influence of the Penning effects on the high-pressure discharge in a neon-xenon mixed gas is investigated in connection with applications to the plasma display panel. A theoretical model for high-pressure discharge is developed. It is shown that the breakdown voltage is reduced by 20 percent at the xenon mole fraction of 0.015, which agree remarkably well with experimental data.

  19. Simultaneous quantitation and identification of organic and inorganic selenium in diet supplements by liquid chromatography with tandem mass spectrometry.

    PubMed

    Zembrzuska, Joanna; Matusiewicz, Henryk; Polkowska-Motrenko, Halina; Chajduk, Ewelina

    2014-01-01

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for selenium speciation in dietary supplements. Chromatographic separation was performed on a TSK-Gel ODS-100V column using a mixture of 5mM ammonium acetate water solution and methanol as a mobile phase. Conditions chosen for this process allowed to separate all investigated chemical compounds of selenium: seleno-l-methionine, methyl-seleno-l-cysteine, l-selenocystine, methaneseleninic acid, selenite and selenate. A tandem mass spectrometer with an ion trap operating in negative or positive ion mode according to the selenium form being determined was used as a detector. Three extraction procedures: water extraction, enzymatic hydrolysis and sequential extraction were used for preparation of samples for the determination of the actual forms of selenium in diet supplements. The developed method was used for analysis of six dietary supplements containing selenium bought in a pharmacy and supermarket. Apart from speciation analysis of selenium content in supplements total selenium content was determined using instrumental neutron activation analysis (INAA). All expected forms of selenium except for selenite were determined using LC-MS/MS technique. It should be stressed that amounts of selenate were smaller than expected. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Ion trap architectures and new directions

    NASA Astrophysics Data System (ADS)

    Siverns, James D.; Quraishi, Qudsia

    2017-12-01

    Trapped ion technology has seen advances in performance, robustness and versatility over the last decade. With increasing numbers of trapped ion groups worldwide, a myriad of trap architectures are currently in use. Applications of trapped ions include: quantum simulation, computing and networking, time standards and fundamental studies in quantum dynamics. Design of such traps is driven by these various research aims, but some universally desirable properties have lead to the development of ion trap foundries. Additionally, the excellent control achievable with trapped ions and the ability to do photonic readout has allowed progress on quantum networking using entanglement between remotely situated ion-based nodes. Here, we present a selection of trap architectures currently in use by the community and present their most salient characteristics, identifying features particularly suited for quantum networking. We also discuss our own in-house research efforts aimed at long-distance trapped ion networking.

  1. Steam trap monitor

    DOEpatents

    Ryan, M.J.

    1987-05-04

    A steam trap monitor positioned downstream of a steam trap in a closed steam system includes a first sensor (a hot finger) for measuring the energy of condensate and a second sensor (a cold finger) for measuring the total energy of condensate and steam in the line. The hot finger includes one or more thermocouples for detecting condensate level and energy, while the cold finger contains a liquid with a lower boiling temperature than that of water. Vapor pressure from the liquid is used to do work such as displacing a piston or bellow in providing an indication of total energy (steam + condensate) of the system. Processing means coupled to and responsive to outputs from the hot and cold fingers subtracts the former from the latter to provide an indication of the presence of steam downstream from the trap indicating that the steam trap is malfunctioning. 2 figs.

  2. Predictors of death and production performance of layer chickens in opened and sealed pens in a tropical savannah environment.

    PubMed

    Shittu, Aminu; Raji, Abdullahi Abdullahi; Madugu, Shuaibu A; Hassan, Akinola Waheed; Fasina, Folorunso Oludayo

    2014-09-12

    Layer chickens are exposed to high risks of production losses and mortality with impact on farm profitability. The harsh tropical climate and severe disease outbreaks, poor biosecurity, sub-minimal vaccination and treatment protocols, poor management practices, poor chick quality, feed-associated causes, and unintended accidents oftentimes aggravate mortality and negatively affect egg production. The objectives of this study were to estimate the probability of survival and evaluate risk factors for death under different intensive housing conditions in a tropical climate, and to assess the production performance in the housing systems. Daily mean mortality percentages and egg production figures were significantly lower and higher in the sealed pens and open houses (P < 0. 001) respectively. The total mean feed consumption/bird/day was similar for the open sided and sealed pens but the mean feed quantity per egg produce was significantly lower in the sealed pens ((P < 0.005). Seasons differently impacted on mortality with the hot-dry season producing significantly higher risk of mortality (61 times) and reduced egg production. Other parameters also differed except the egg production during the cold-dry season. Layers in sealed pens appear to have higher probability of survival and the Kaplan-Meir survival curves differed for each pen; ≥ 78 weeks old layer have higher probability of survival compared with the younger chickens and the 19-38 weeks age category are at highest risk of death (P < 0.001). The hazard-ratio for mortality of layers raised in sealed pens was 0.568 (56.8%). Reasons for spiked mortality in layer chickens may not always be associated with disease. Hot-dry climatic environment is associated with heat stress, waning immunity and inefficient feed usage and increase probability of death with reduced egg production; usage of environmentally controlled building in conditions where environmental temperature may rise significantly above 25°C will

  3. Servo control of an optical trap.

    PubMed

    Wulff, Kurt D; Cole, Daniel G; Clark, Robert L

    2007-08-01

    A versatile optical trap has been constructed to control the position of trapped objects and ultimately to apply specified forces using feedback control. While the design, development, and use of optical traps has been extensive and feedback control has played a critical role in pushing the state of the art, few comprehensive examinations of feedback control of optical traps have been undertaken. Furthermore, as the requirements are pushed to ever smaller distances and forces, the performance of optical traps reaches limits. It is well understood that feedback control can result in both positive and negative effects in controlled systems. We give an analysis of the trapping limits as well as introducing an optical trap with a feedback control scheme that dramatically improves an optical trap's sensitivity at low frequencies.

  4. Gated charged-particle trap

    DOEpatents

    Benner, W.H.

    1999-03-09

    The design and operation of a new type of charged-particle trap provides simultaneous measurements of mass, charge, and velocity of large electrospray ions. The trap consists of a detector tube mounted between two sets of center-bored trapping plates. Voltages applied to the trapping plates define symmetrically-opposing potential valleys which guide axially-injected ions to cycle back and forth through the charge-detection tube. A low noise charge-sensitive amplifier, connected to the tube, reproduces the image charge of individual ions as they pass through the detector tube. Ion mass is calculated from measurement of ion charge and velocity following each passage through the detector. 5 figs.

  5. Targeted tandem duplication of a large chromosomal segment in Aspergillus oryzae.

    PubMed

    Takahashi, Tadashi; Sato, Atsushi; Ogawa, Masahiro; Hanya, Yoshiki; Oguma, Tetsuya

    2014-08-01

    We describe here the first successful construction of a targeted tandem duplication of a large chromosomal segment in Aspergillus oryzae. The targeted tandem chromosomal duplication was achieved by using strains that had a 5'-deleted pyrG upstream of the region targeted for tandem chromosomal duplication and a 3'-deleted pyrG downstream of the target region. Consequently,strains bearing a 210-kb targeted tandem chromosomal duplication near the centromeric region of chromosome 8 and strains bearing a targeted tandem chromosomal duplication of a 700-kb region of chromosome 2 were successfully constructed. The strains bearing the tandem chromosomal duplication were efficiently obtained from the regenerated protoplast of the parental strains. However, the generation of the chromosomal duplication did not depend on the introduction of double-stranded breaks(DSBs) by I-SceI. The chromosomal duplications of these strains were stably maintained after five generations of culture under nonselective conditions. The strains bearing the tandem chromosomal duplication in the 700-kb region of chromosome 2 showed highly increased protease activity in solid-state culture, indicating that the duplication of large chromosomal segments could be a useful new breeding technology and gene analysis method.

  6. Microfabricated linear Paul-Straubel ion trap

    DOEpatents

    Mangan, Michael A [Albuquerque, NM; Blain, Matthew G [Albuquerque, NM; Tigges, Chris P [Albuquerque, NM; Linker, Kevin L [Albuquerque, NM

    2011-04-19

    An array of microfabricated linear Paul-Straubel ion traps can be used for mass spectrometric applications. Each ion trap comprises two parallel inner RF electrodes and two parallel outer DC control electrodes symmetric about a central trap axis and suspended over an opening in a substrate. Neighboring ion traps in the array can share a common outer DC control electrode. The ions confined transversely by an RF quadrupole electric field potential well on the ion trap axis. The array can trap a wide array of ions.

  7. Fiber supercapacitors utilizing pen ink for flexible/wearable energy storage.

    PubMed

    Fu, Yongping; Cai, Xin; Wu, Hongwei; Lv, Zhibin; Hou, Shaocong; Peng, Ming; Yu, Xiao; Zou, Dechun

    2012-11-08

    A novel type of flexible fiber/wearable supercapacitor that is composed of two fiber electrodes - a helical spacer wire and an electrolyte - is demonstrated. In the carbon-based fiber supercapacitor (FSC), which has high capacitance performance, commercial pen ink is directly utilized as the electrochemical material. FSCs have potential benefits in the pursuit of low-cost, large-scale, and efficient flexible/wearable energy storage systems. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Hot pen and laser writable photonic polymer films

    NASA Astrophysics Data System (ADS)

    Moirangthem, Monali; Stumpel, Jelle E.; Alp, Baran; Teunissen, Pit; Bastiaansen, Cees W. M.; Schenning, Albertus P. H. J.

    2016-03-01

    An orange-reflecting photonic polymer film has been fabricated based on a hydrogen-bonded cholesteric liquid crystalline (CLC) polymer consisting of non-reactive (R)-(+)-3-methyladipic acid as the chiral dopant. This polymer film can be patterned easily by evaporating the chiral dopant at specific locations with a hot pen or a laser beam. Removal of chiral dopant leads to a decrease in the helical pitch at the heat treated areas leading to a change in color from orange to green revealing a high contrast pattern. The photonic patterns are irreversible and stable at ambient conditions. This makes such a CLC polymer film interesting as writable photonic paper.

  9. Efficiency of malaise traps and colored pan traps for collecting flower visiting insects from three forested ecosystems

    Treesearch

    Joshua W. Campbell; J.L. Hanula

    2007-01-01

    Pan and Malaise traps have been used widely to sample insect abundance and diversity, but no studies have compared their performance for sampling pollinators in forested ecosystems. Malaise trap design and color of pan traps are important parameters that influence insect pollinator catches. We compared pan trap (blue, yellow, white, and red) and Malaise trap catches...

  10. Inclusion complexes of β-cyclodextrin-dinitrocompounds as UV absorber for ballpoint pen ink.

    PubMed

    Srinivasan, Krishnan; Radhakrishnan, S; Stalin, Thambusamy

    2014-08-14

    2,4-Dinitrophenol (2,4-DNP), 2,4-dinitroaniline (2,4-DNA), 2,6-dinitroaniline (2,6-DNA) and 2,6-dinitrobenzoic acid (2,6-DNB) has appeared for the UV absorption bands in different wavelength region below 400 nm, a combination of these dinitro aromatic compounds gave the broad absorption spectra within the UV region. The absorption intensities have been increased by preparation of the inclusion complex of dinitro compounds with β-cyclodextrin (β-CD). Prepared inclusion complexes are used to improve the UV protection properties of the ball point pen ink against photo degradation. The formation of solid inclusion complexes was characterized by FT-IR, and (1)H NMR spectroscopy. The UV protecting properties of these inclusion complexes were calculated their sun protection factor (SPF) is also discussed. The stability of the ballpoint pen ink has been confirmed by UV-Visible spectroscopic method. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Induction of trap formation in nematode-trapping fungi by bacteria-released ammonia.

    PubMed

    Su, H N; Xu, Y Y; Wang, X; Zhang, K Q; Li, G H

    2016-04-01

    A total of 11 bacterial strains were assayed for bacteria-induced trap formation in the nematode-trapping fungus Arthrobotrys oligospora YMF1·01883 with two-compartmented Petri dish. These strains were identified on the basis of their 16S rRNA gene sequences. Volatile organic compounds (VOCs) of eight isolates were extracted using solid-phase micro-extraction (SPME) and their structures were identified based on gas chromatography-mass spectrometry (GC-MS). At the same time, all isolates were used for quantitative measurement of ammonia by the indophenol blue method. The effects of pure commercial compounds on inducement of trap formation in A. oligospora were tested. Taken together, results demonstrated that the predominant bacterial volatile compound inducing trap formation was ammonia. Meanwhile, ammonia also played a role in other nematode-trapping fungi, including Arthrobotrys guizhouensis YMF1·00014, producing adhesive nets; Dactylellina phymatopaga YMF1·01474, producing adhesive knobs; Dactylellina cionopaga YMF1·01472, producing adhesive columns and Drechslerella brochopaga YMF1·01829, producing constricting rings. © 2016 The Society for Applied Microbiology.

  12. Synthesis of poly(ethylene furandicarboxylate) polyester using monomers derived from renewable resources: thermal behavior comparison with PET and PEN.

    PubMed

    Papageorgiou, George Z; Tsanaktsis, Vasilios; Bikiaris, Dimitrios N

    2014-05-07

    Poly(ethylene-2,5-furandicarboxylate) (PEF) is a new alipharomatic polyester that can be prepared from monomers derived from renewable resources like furfural and hydroxymethylfurfural. For this reason it has gained high interest recently. In the present work it was synthesized from the dimethylester of 2,5-furandicarboxylic acid and ethylene glycol by applying the two-stage melt polycondensation method. The thermal behavior of PEF was studied in comparison to its terephthalate and naphthalate homologues poly(ethylene terephthalate) (PET) and poly(ethylene naphthalate) (PEN), which were also synthesized following the same procedure. The equilibrium melting point of PEF was found to be 265 °C while the heat of fusion for the pure crystalline PEF was estimated to be about 137 J g(-1). The crystallization kinetics was analyzed using various models. PET showed faster crystallization rates than PEN and this in turn showed faster crystallization than PEF, under both isothermal and non-isothermal conditions. The spherulitic morphology of PEF during isothermal crystallization was investigated by polarized light microscopy (PLM). A large nucleation density and a small spherulite size were observed for PEF even at low supercoolings, in contrast to PET or PEN. Thermogravimetric analysis indicated that PEF is thermally stable up to 325 °C and the temperature for the maximum degradation rate was 438 °C. These values were a little lower than those for PET or PEN.

  13. Plasma potential and electron temperature evaluated by ball-pen and Langmuir probes in the COMPASS tokamak

    NASA Astrophysics Data System (ADS)

    Dimitrova, M.; Popov, Tsv K.; Adamek, J.; Kovačič, J.; Ivanova, P.; Hasan, E.; López-Bruna, D.; Seidl, J.; Vondráček, P.; Dejarnac, R.; Stöckel, J.; Imríšek, M.; Panek, R.; the COMPASS Team

    2017-12-01

    The radial distributions of the main plasma parameters in the scrape-off-layer of the COMPASS tokamak are measured during L-mode and H-mode regimes by using both Langmuir and ball-pen probes mounted on a horizontal reciprocating manipulator. The radial profile of the plasma potential derived previously from Langmuir probes data by using the first derivative probe technique is compared with data derived using ball-pen probes. A good agreement can be seen between the data acquired by the two techniques during the L-mode discharge and during the H-mode regime within the inter-ELM periods. In contrast with the first derivative probe technique, the ball-pen probe technique does not require a swept voltage and, therefore, the temporal resolution is only limited by the data acquisition system. In the electron temperature evaluation, in the far scrape-off layer and in the limiter shadow, where the electron energy distribution is Maxwellian, the results from both techniques match well. In the vicinity of the last closed flux surface, where the electron energy distribution function is bi-Maxwellian, the ball-pen probe technique results are in agreement with the high-temperature components of the electron distribution only. We also discuss the application of relatively large Langmuir probes placed in parallel and perpendicularly to the magnetic field lines to studying the main plasma parameters. The results obtained by the two types of the large probes agree well. They are compared with Thomson scattering data for electron temperatures and densities. The results for the electron densities are compared also with the results from ASTRA code calculation of the electron source due to the ionization of the neutrals by fast electrons and the origin of the bi-Maxwellian electron energy distribution function is briefly discussed.

  14. The Pen Branch Project: Restoration of a Forested Wetland in South Carolina

    Treesearch

    Randall K. Kolka; Eric A. Nelson; Ronald E. Bonar; Neil C. Dulohery; David Gartner

    1998-01-01

    The Pen Branch Project is a program to restore a forested riparian wetland that has been subject to thermal disturbance caused by nuclear reactor operations at the Department of Energy's (DOE) Savannah River Site (SRS), an 80,200-hectare nuclear facility located in South Carolina. Various levels of thermal discharges to streams located across the US. have occurred...

  15. Alpha particle confinement in tandem mirrors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Devoto, R.S.; Ohnishi, M.; Kerns, J.

    1980-10-10

    Mechanisms leading to loss of alpha particles from non-axisymmetric tandem mirrors are considered. Stochastic diffusion due to bounce-drift resonances, which can cause rapid radial losses of high-energy alpha particles, can be suppressed by imposing a 20% rise in axisymmetric fields before the quadrupole transition sections. Alpha particles should then be well-confined until thermal energies when they enter the resonant plateau require. A fast code for computation of drift behavior in reactors is described. Sample calculations are presented for resonant particles in a proposed coil set for the Tandem Mirror Next Step.

  16. Tandem mobile robot system

    DOEpatents

    Buttz, James H.; Shirey, David L.; Hayward, David R.

    2003-01-01

    A robotic vehicle system for terrain navigation mobility provides a way to climb stairs, cross crevices, and navigate across difficult terrain by coupling two or more mobile robots with a coupling device and controlling the robots cooperatively in tandem.

  17. Determination of type B fumonisin mycotoxins in maize and maize-based products by liquid chromatography/tandem mass spectrometry using a QqQlinear ion trap mass spectrometer.

    PubMed

    Faberi, Angelo; Foglia, Patrizia; Pastorini, Elisabetta; Samperi, Roberto; Laganà, Aldo

    2005-01-01

    A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for determining the type B fumonisin mycotoxins in corn-based foodstuffs is described. Fumonisins FB1 and FB2 were extracted from a 1 g sample by homogenization with acetonitrile/water (75:25, v/v, 50 mmol/L formic acid, 25 mL final volume) and the extract was defatted on C18 phase. Volumes of 5 mL of crude extracts were cleaned up on Carbograph-4 cartridges. The final solution was analyzed by HPLC with electrospray ionization mass spectrometry in positive ion mode using multiple reaction monitoring with a QqQ linear ion trap mass spectrometer. Recoveries for spiked corn-based foodstuffs ranged from 91-105% (RSD% < or =8%), and method detection limits were < or =2 ng/g for FB1 and < or =1 ng/g for FB2. Two different spiking levels were tested (5000 and 100 ng/g for FB1, 1000 and 20 ng/g for FB2). Quantitation was achieved by an external calibration procedure using matrix-matched standards, with diclofenac added post-cleanup as internal standard for the LC/MS/MS analyses. Calibration curves showed linearity in the concentration range 0.005-5 ng/microL of final extract (0.992 < or = R2< or =0.995). Two other fumonisins, FB3 and FB4, were identified in naturally contaminated samples of corn meal using an information-dependent acquisition protocol that looped three experiments, including neutral loss scan, enhanced resolution scan, and enhanced product ion scan. FB3 and FB4 quantitation was estimated as peak area ratios relative to the FB2 response in view of the lack of both standards. This work also includes an application of the present LC/MS/MS method to some maize and maize-based product samples (corn meal, cornflakes and popcorn) collected from Italian stores. FB1 and FB2 contamination levels exceeding the European Union recommendation were found in 8 out of 15 corn meal samples.

  18. Tandem internal models execute motor learning in the cerebellum.

    PubMed

    Honda, Takeru; Nagao, Soichi; Hashimoto, Yuji; Ishikawa, Kinya; Yokota, Takanori; Mizusawa, Hidehiro; Ito, Masao

    2018-06-25

    In performing skillful movement, humans use predictions from internal models formed by repetition learning. However, the computational organization of internal models in the brain remains unknown. Here, we demonstrate that a computational architecture employing a tandem configuration of forward and inverse internal models enables efficient motor learning in the cerebellum. The model predicted learning adaptations observed in hand-reaching experiments in humans wearing a prism lens and explained the kinetic components of these behavioral adaptations. The tandem system also predicted a form of subliminal motor learning that was experimentally validated after training intentional misses of hand targets. Patients with cerebellar degeneration disease showed behavioral impairments consistent with tandemly arranged internal models. These findings validate computational tandemization of internal models in motor control and its potential uses in more complex forms of learning and cognition. Copyright © 2018 the Author(s). Published by PNAS.

  19. cDNA cloning, characterization and expression analysis of a novel antimicrobial peptide gene penaeidin-3 (Fi-Pen3) from the haemocytes of Indian white shrimp Fenneropenaeus indicus.

    PubMed

    Shanthi, S; Vaseeharan, B

    2012-03-20

    A new member of antimicrobial peptide genes of the penaeidin family, penaeidin 3, was cloned from the haemocytes of Indian white shrimp Fenneropeneaus indicus (F. indicus), by reverse transcription PCR (RT-PCR) and rapid amplification of cDNA end (RACE-PCR) methods. The complete nucleotide sequence of cDNA clone of Indian white shrimp F. indicus Penaeidin 3 (Fi-Pen3) was 243bp long and has an open reading frame which encodes 80 amino acid peptide. The homology analysis of Fi-Pen3 sequence with other Penaeidins 3 shows higher similarity with Penaeus monodon (92%). The theoretical 3D structure generated through ab initio modelling indicated the presence of two-disulphide bridges in the alpha-helix. The signal peptide sequence of Fi-Pen3 is almost entirely homologous to that of other Penaeidin 3 of crustaceans, while differing relatively in the N-terminal domain of the mature peptide. The mature peptide has a predicted molecular weight of 84.9kDa, and a theoretical pI of 9.38. Phylogenetic analysis of Fi-Pen3 shows high resemblance with other Pen-3 from P. monodon, Litopenaeus stylirostris, Litopenaeus vannamei and Litopenaeus setiferus. Fi-Pen3 found to be expressed in haemocytes, heart, hepatopancreas, muscles, gills, intestine, and eyestalk with higher expression in haemocytes. Microbial challenge resulted in mRNA up-regulation, up to 6h post injection of Vibrio parahemolyticus. The Fi-Pen3 mRNA expression of F. indicus in the premolt stage (D(01) and D(02)) was significantly up-regulated than the postmolt (A and B) and intermolt stages (C). The findings of the present paper underline the involvement of Fi-Pen3 in innate immune system of F. indicus. Copyright © 2011 Elsevier GmbH. All rights reserved.

  20. Optical trapping of nanoshells

    NASA Astrophysics Data System (ADS)

    Hester, Brooke C.; Crawford, Alice; Kishore, Rani B.; Helmerson, Kristian; Halas, Naomi J.; Levin, Carly

    2007-09-01

    We investigate near-resonant trapping of Rayleigh particles in optical tweezers. Although optical forces due to a near-resonant laser beam have been extensively studied for atoms, the situation for larger particles is that the laser wavelength is far from any absorption resonance. Theory predicts, however, that the trapping force exerted on a Rayleigh particle is enhanced, and may be three to fifty times larger for frequencies near resonance than for frequencies far off resonance. The ability to selectively trap only particles with a given absorption peak may have many practical applications. In order to investigate near-resonant trapping we are using nanoshells, particles with a dielectric core and metallic coating that can exhibit plasmon resonances. The resonances of the nanoshells can be tuned by adjusting the ratio of the radius of the dielectric core, r I, to the overall radius, r II, which includes the thickness of the metallic coating. Our nanoshells, fabricated at Rice University, consist of a silica core with a gold coating. Using back focal plane detection, we measure the trap stiffness of a single focus optical trap (optical tweezers), from a diode laser at 853 nm for nanoshells with several different r I/r II ratios.

  1. Quality evaluation of tandem mass spectral libraries.

    PubMed

    Oberacher, Herbert; Weinmann, Wolfgang; Dresen, Sebastian

    2011-06-01

    Tandem mass spectral libraries are gaining more and more importance for the identification of unknowns in different fields of research, including metabolomics, forensics, toxicology, and environmental analysis. Particularly, the recent invention of reliable, robust, and transferable libraries has increased the general acceptance of these tools. Herein, we report on results obtained from thorough evaluation of the match reliabilities of two tandem mass spectral libraries: the MSforID library established by the Oberacher group in Innsbruck and the Weinmann library established by the Weinmann group in Freiburg. Three different experiments were performed: (1) Spectra of the libraries were searched against their corresponding library after excluding either this single compound-specific spectrum or all compound-specific spectra prior to searching; (2) the libraries were searched against each other using either library as reference set or sample set; (3) spectra acquired on different mass spectrometric instruments were matched to both libraries. Almost 13,000 tandem mass spectra were included in this study. The MSforID search algorithm was used for spectral matching. Statistical evaluation of the library search results revealed that principally both libraries enable the sensitive and specific identification of compounds. Due to higher mass accuracy of the QqTOF compared with the QTrap instrument, matches to the MSforID library were more reliable when comparing spectra with both libraries. Furthermore, only the MSforID library was shown to be efficiently transferable to different kinds of tandem mass spectrometers, including "tandem-in-time" instruments; this is due to the coverage of a large range of different collision energy settings-including the very low range-which is an outstanding characteristics of the MSforID library.

  2. Nanocrystal assembly for tandem catalysis

    DOEpatents

    Yang, Peidong; Somorjai, Gabor; Yamada, Yusuke; Tsung, Chia-Kuang; Huang, Wenyu

    2014-10-14

    The present invention provides a nanocrystal tandem catalyst comprising at least two metal-metal oxide interfaces for the catalysis of sequential reactions. One embodiment utilizes a nanocrystal bilayer structure formed by assembling sub-10 nm platinum and cerium oxide nanocube monolayers on a silica substrate. The two distinct metal-metal oxide interfaces, CeO.sub.2--Pt and Pt--SiO.sub.2, can be used to catalyze two distinct sequential reactions. The CeO.sub.2--Pt interface catalyzed methanol decomposition to produce CO and H.sub.2, which were then subsequently used for ethylene hydroformylation catalyzed by the nearby Pt--SiO.sub.2 interface. Consequently, propanal was selectively produced on this nanocrystal bilayer tandem catalyst.

  3. Development of extractive electrospray ionization ion trap mass spectrometry for in vivo breath analysis.

    PubMed

    Ding, Jianhua; Yang, Shuiping; Liang, Dapeng; Chen, Huanwen; Wu, Zhuanzhang; Zhang, Lili; Ren, Yulin

    2009-10-01

    In metabolomics studies and clinical diagnosis, interest is increasing in the rapid analysis of exhaled breath. In vivo breath analysis offers a unique, unobtrusive, non-invasive method of investigating human metabolism. To analyze breath in vivo, we constructed a novel platform of extractive electrospray ionization (EESI) ion trap mass spectrometry (ITMS) using a home-made EESI source coupled to a linear trap quadrupole mass spectrometer. A reference compound (authentic n-octyl amine) was used to evaluate effects of systematically varying selected characteristics of the EESI source on signal intensity. Under the optimized working conditions, metabolic changes of human bodies were in vivo followed by performing rapid breath analysis using the multi-stage EESI-ITMS tandem mass spectrometry platform. For nicotine, a limit of determination was found to be 0.05 fg mL(-1) (S/N = 3, RSD = 5.0 %, n = 10) for nicotine in aerosol standard samples; the dynamic response range was from 0.0155 pg mL(-1) to 155 pg mL(-1). The concentration of nicotine in the exhaled breath of a regular smoker was in vivo determined to be 5.8 pg mL(-1), without any sample pre-treatment. Our results show that EESI-ITMS is a powerful analytical platform to provide high sensitivity, high specificity and high throughput for semi-quantitative analysis of complex samples in life science, particularly for in vivo metabolomics studies.

  4. Non-target captures during small mammal trapping with snap traps

    Treesearch

    David G. Peitz; Philip A. Tappe; Ronald E. Thill; Roger W. Perry; M. Anthony Melchiors; T. Bently Wigley

    2001-01-01

    There is little published information available on non-target captures during small mammal trapping. We used a variety of snap traps baited with a rolled oat-peanut butter mix to capture 2,054 individuals from 9 genera of small mammals in a study of small mammal and avian community structure in riparian areas and adjacent loblolly pine (Pinus taeda) plantations. We...

  5. Single-task and dual-task tandem gait test performance after concussion.

    PubMed

    Howell, David R; Osternig, Louis R; Chou, Li-Shan

    2017-07-01

    To compare single-task and dual-task tandem gait test performance between athletes after concussion with controls on observer-timed, spatio-temporal, and center-of-mass (COM) balance control measurements. Ten participants (19.0±5.5years) were prospectively identified and completed a tandem gait test protocol within 72h of concussion and again 1 week, 2 weeks, 1 month, and 2 months post-injury. Seven uninjured controls (20.0±4.5years) completed the same protocol in similar time increments. Tandem gait test trials were performed with (dual-task) and without (single-task) concurrently performing a cognitive test as whole-body motion analysis was performed. Outcome variables included test completion time, average tandem gait velocity, cadence, and whole-body COM frontal plane displacement. Concussion participants took significantly longer to complete the dual-task tandem gait test than controls throughout the first 2 weeks post-injury (mean time=16.4 [95% CI: 13.4-19.4] vs. 10.1 [95% CI: 6.4-13.7] seconds; p=0.03). Single-task tandem gait times were significantly lower 72h post-injury (p=0.04). Dual-task cadence was significantly lower for concussion participants than controls (89.5 [95% CI: 68.6-110.4] vs. 127.0 [95% CI: 97.4-156.6] steps/minute; p=0.04). Moderately-high to high correlations between tandem gait test time and whole-body COM medial-lateral displacement were detected at each time point during dual-task gait (r s =0.70-0.93; p=0.03-0.001). Adding a cognitive task during the tandem gait test resulted in longer detectable deficits post-concussion compared to the traditional single-task tandem gait test. As a clinical tool to assess dynamic motor function, tandem gait may assist with return to sport decisions after concussion. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  6. A circularly polarized optical dipole trap and other developments in laser trapping of atoms

    NASA Astrophysics Data System (ADS)

    Corwin, Kristan Lee

    Several innovations in laser trapping and cooling of alkali atoms are described. These topics share a common motivation to develop techniques for efficiently manipulating cold atoms. Such advances facilitate sensitive precision measurements such as parity non- conservation and 8-decay asymmetry in large trapped samples, even when only small quantities of the desired species are available. First, a cold, bright beam of Rb atoms is extracted from a magneto-optical trap (MOT) using a very simple technique. This beam has a flux of 5 × 109 atoms/s and a velocity of 14 m/s, and up to 70% of the atoms in the MOT were transferred to the atomic beam. Next, a highly efficient MOT for radioactive atoms is described, in which more than 50% of 221Fr atoms contained in a vapor cell are loaded into a MOT. Measurements were also made of the 221Fr 7 2P1/2 and 7 2P3/2 energies and hyperfine constants. To perform these experiments, two schemes for stabilizing the frequency of the light from a diode laser were developed and are described in detail. Finally, a new type of trap is described and a powerful cooling technique is demonstrated. The circularly polarized optical dipole trap provides large samples of highly spin-polarized atoms, suitable for many applications. Physical processes that govern the transfer of large numbers of atoms into the trap are described, and spin-polarization is measured to be 98(1)%. In addition, the trap breaks the degeneracy of the atomic spin states much like a magnetic trap does. This allows for RF and microwave cooling via both forced evaporation and a Sisyphus mechanism. Preliminary application of these techniques to the atoms in the circularly polarized dipole trap has successfully decreased the temperature by a factor of 4 while simultaneously increasing phase space density.

  7. Effect of sand and rubber surface on the lying behavior of lame dairy cows in hospital pens.

    PubMed

    Bak, A S; Herskin, M S; Jensen, M B

    2016-04-01

    Housing lame cows in designated hospital pens with a soft surface may lessen the pain the animals feel when lying and changing position. This study investigated the effect of the lying surface on the behavior of lame cows in hospital pens. Thirty-two lame dairy cows were kept in individual hospital pens, provided with either 30-cm deep-bedded sand or 24-mm rubber mats during 24 h in a crossover design. On each surface, the lying behavior of each cow was recorded during 18 h. On deep-bedded sand, cows lay down more and changed position more often than when housed on the rubber surface. Furthermore, a shorter duration of lying down and getting up movements and a shorter duration of lying intention movements were observed. These results suggest that lame dairy cows are more reluctant to change position on rubber compared with sand, and that sand is more comfortable to lie on. Thus, deep bedding such as sand may provide better lying comfort for lame cows than an unbedded rubber surface. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  8. Effect of SiO2 grafted MWCNTs on the mechanical and dielectric properties of PEN composite films

    NASA Astrophysics Data System (ADS)

    Jin, Fei; Feng, Mengna; Huang, Xu; Long, Cheng; Jia, Kun; Liu, Xiaobo

    2015-12-01

    In this study, the functional poly (arylene ether nitrile) (PEN)/multiwall carbon nanotubes (MWCNTs)/SiO2 nanocomposite with high mechanical and good electrical properties were fabricated through a simple and effective method. Specifically, the surface modification using highly ordered and porous SiO2 not only improves the dispersion of the MWCNTs in polymer matrix, but also combines the excellent properties of SiO2 and MWCNTs. Transmission electron microscopy (TEM), Fourier transform infrared spectra (FTIR), and scanning electron microscope (SEM) were employed to confirm the surface functionalization of MWCNTs. As a result, all the composite films exhibited good dielectric properties with high dielectric constant of 7 as well as low dielectric loss of 0.04. Besides, the results of mechanical tests showed that the tensile strength and modulus reached their highest values at the 2 wt% MWCNTs-SiO2 loading content (125 MPa and 2950 MPa, respectively). The rheological results showed that MWCNTs-SiO2/PEN composites have a typical solid-like viscoelastic response as frequencies changes. Therefore, all the results revealed that surface functionalization has strong influence on the dispersion state of MWCNTs in PEN matrix.

  9. In Vivo-Selected Compensatory Mutations Restore the Fitness Cost of Mosaic penA Alleles That Confer Ceftriaxone Resistance in Neisseria gonorrhoeae.

    PubMed

    Vincent, Leah R; Kerr, Samuel R; Tan, Yang; Tomberg, Joshua; Raterman, Erica L; Dunning Hotopp, Julie C; Unemo, Magnus; Nicholas, Robert A; Jerse, Ann E

    2018-04-03

    Resistance to ceftriaxone in Neisseria gonorrhoeae is mainly conferred by mosaic penA alleles that encode penicillin-binding protein 2 (PBP2) variants with markedly lower rates of acylation by ceftriaxone. To assess the impact of these mosaic penA alleles on gonococcal fitness, we introduced the mosaic penA alleles from two ceftriaxone-resistant (Cro r ) clinical isolates (H041 and F89) into a Cro s strain (FA19) by allelic exchange and showed that the resultant Cro r mutants were significantly outcompeted by the Cro s parent strain in vitro and in a murine infection model. Four Cro r compensatory mutants of FA19 penA41 were isolated independently from mice that outcompeted the parent strain both in vitro and in vivo One of these compensatory mutants (LV41C) displayed a unique growth profile, with rapid log growth followed by a sharp plateau/gradual decline at stationary phase. Genome sequencing of LV41C revealed a mutation (G348D) in the acnB gene encoding the bifunctional aconitate hydratase 2/2 methylisocitrate dehydratase. Introduction of the acnB G348D allele into FA19 penA41 conferred both a growth profile that phenocopied that of LV41C and a fitness advantage, although not as strongly as that exhibited by the original compensatory mutant, suggesting the existence of additional compensatory mutations. The mutant aconitase appears to be a functional knockout with lower activity and expression than wild-type aconitase. Transcriptome sequencing (RNA-seq) analysis of FA19 penA41 acnB G348D revealed a large set of upregulated genes involved in carbon and energy metabolism. We conclude that compensatory mutations can be selected in Cro r gonococcal strains that increase metabolism to ameliorate their fitness deficit. IMPORTANCE The emergence of ceftriaxone-resistant (Cro r ) Neisseria gonorrhoeae has led to the looming threat of untreatable gonorrhea. Whether Cro resistance is likely to spread can be predicted from studies that compare the relative fitnesses of

  10. Efficacy of multifunnel traps for capturing emerald ash borer (Coleoptera: Buprestidae): effect of color, glue, and other trap coatings.

    PubMed

    Francese, Joseph A; Fraser, Ivich; Lance, David R; Mastro, Victor C

    2011-06-01

    Tens of thousands of adhesive-coated purple prism traps are deployed annually in the United States to survey for the invasive emerald ash borer, Agrilus planipennis Fairmaire (Coleoptera: Buprestidae). A reusable, more user-friendly trap is desired by program managers, surveyors, and researchers. Field assays were conducted in southeastern Michigan to ascertain the feasibility of using nonsticky traps as survey and detection tools for emerald ash borer. Three nonsticky trap designs, including multifunnel (Lindgren), modified intercept panel, and drainpipe (all painted purple) were compared with the standard purple prism trap; no statistical differences in capture of emerald ash borer adults were detected between the multifunnel design and the prism. In subsequent color comparison assays, both green- and purple-painted multifunnel traps (and later, plastic versions of these colors) performed as well or better than the prism traps. Multifunnel traps coated with spray-on adhesive caught more beetles than untreated traps. The increased catch, however, occurred in the traps' collection cups and not on the trap surface. In a separate assay, there was no significant difference detected between glue-coated traps and Rain-X (normally a glass treatment)-coated traps, but both caught significantly more A. planipennis adults than untreated traps.

  11. Ultra High Resolution Linear Ion Trap Orbitrap Mass Spectrometer (Orbitrap Elite) Facilitates Top Down LC MS/MS and Versatile Peptide Fragmentation Modes*

    PubMed Central

    Michalski, Annette; Damoc, Eugen; Lange, Oliver; Denisov, Eduard; Nolting, Dirk; Müller, Mathias; Viner, Rosa; Schwartz, Jae; Remes, Philip; Belford, Michael; Dunyach, Jean-Jacques; Cox, Juergen; Horning, Stevan; Mann, Matthias; Makarov, Alexander

    2012-01-01

    Although only a few years old, the combination of a linear ion trap with an Orbitrap analyzer has become one of the standard mass spectrometers to characterize proteins and proteomes. Here we describe a novel version of this instrument family, the Orbitrap Elite, which is improved in three main areas. The ion transfer optics has an ion path that blocks the line of sight to achieve more robust operation. The tandem MS acquisition speed of the dual cell linear ion trap now exceeds 12 Hz. Most importantly, the resolving power of the Orbitrap analyzer has been increased twofold for the same transient length by employing a compact, high-field Orbitrap analyzer that almost doubles the observed frequencies. An enhanced Fourier Transform algorithm—incorporating phase information—further doubles the resolving power to 240,000 at m/z 400 for a 768 ms transient. For top-down experiments, we combine a survey scan with a selected ion monitoring scan of the charge state of the protein to be fragmented and with several HCD microscans. Despite the 120,000 resolving power for SIM and HCD scans, the total cycle time is within several seconds and therefore suitable for liquid chromatography tandem MS. For bottom-up proteomics, we combined survey scans at 240,000 resolving power with data-dependent collision-induced dissociation of the 20 most abundant precursors in a total cycle time of 2.5 s—increasing protein identifications in complex mixtures by about 30%. The speed of the Orbitrap Elite furthermore allows scan modes in which complementary dissociation mechanisms are routinely obtained of all fragmented peptides. PMID:22159718

  12. Direct high-precision measurement of the magnetic moment of the proton.

    PubMed

    Mooser, A; Ulmer, S; Blaum, K; Franke, K; Kracke, H; Leiteritz, C; Quint, W; Rodegheri, C C; Smorra, C; Walz, J

    2014-05-29

    One of the fundamental properties of the proton is its magnetic moment, µp. So far µp has been measured only indirectly, by analysing the spectrum of an atomic hydrogen maser in a magnetic field. Here we report the direct high-precision measurement of the magnetic moment of a single proton using the double Penning-trap technique. We drive proton-spin quantum jumps by a magnetic radio-frequency field in a Penning trap with a homogeneous magnetic field. The induced spin transitions are detected in a second trap with a strong superimposed magnetic inhomogeneity. This enables the measurement of the spin-flip probability as a function of the drive frequency. In each measurement the proton's cyclotron frequency is used to determine the magnetic field of the trap. From the normalized resonance curve, we extract the particle's magnetic moment in terms of the nuclear magneton: μp = 2.792847350(9)μN. This measurement outperforms previous Penning-trap measurements in terms of precision by a factor of about 760. It improves the precision of the forty-year-old indirect measurement, in which significant theoretical bound state corrections were required to obtain µp, by a factor of 3. By application of this method to the antiproton magnetic moment, the fractional precision of the recently reported value can be improved by a factor of at least 1,000. Combined with the present result, this will provide a stringent test of matter/antimatter symmetry with baryons.

  13. Authentic Reading, Writing, and Discussion: An Exploratory Study of a Pen Pal Project

    ERIC Educational Resources Information Center

    Gambrell, Linda B.; Hughes, Elizabeth M.; Calvert, Leah; Malloy, Jacquelynn A.; Igo, Brent

    2011-01-01

    In this exploratory study, reading, writing, and discussion were examined within the context of a pen pal intervention focusing on authentic literacy tasks. The study employed a mixed-method design with a triangulation-convergence model to explore the relationship between authentic literacy tasks and the literacy motivation of elementary students…

  14. Negotiating Multiple Identities through eTandem Learning Experiences

    ERIC Educational Resources Information Center

    Yang, Se Jeong; Yi, Youngjoo

    2017-01-01

    Much of eTandem research has investigated either linguistic or cross-cultural aspects of second language (L2) learning, but relatively little is known about issues of identity construction in an eTandem context. Situating the study within theories and research of language learner identity, we examined ways in which two adult L2 learners (a Korean…

  15. Simultaneous trapping of rubidium-85 and rubidium-87 in a far off resonant trap

    NASA Astrophysics Data System (ADS)

    Gorges, Anthony R.

    The experiments described in this thesis were focused on the physics of simultaneous trapping of 85Rb and 87 Rb into a Far Off Resonant Trap (FORT), with a view towards the implementation of a nonevaporative cooling scheme. Atoms were first trapped in a Magneto Optical Trap (MOT) and from there loaded into the FORT. We investigated the effects of loading the FORT from a MOT vs. an optical molasses; observing that the molasses significantly improved the trapped atom number. The ultimate number of atoms trapped is determined by a balance between efficient laser cooling into the FORT and light-assisted collisional losses from the FORT. We have studied and measured the loss rates associated with light-assisted collisions for our FORT, measuring both heteronuclear and homonuclear collisions. It was discovered that induced long range dipole-dipole interactions between 85Rb and 87Rb have a significant impact on FORT loading. This interaction interferes with the loading into the trap and thus limits the number of atoms which can be trapped in the FORT under simultaneous load conditions. Despite this limitation, all required experimental parameters for our future measurements have been met. In addition to these FORT studies, we have found a technique which can successfully mitigate the effects of reabsorption in optically thick clouds, which is a limitation to the ultimate temperature an atom cloud will reach during light-based cooling. Planned future measurements for this project include the creation of a variable aspect ratio FORT; along with investigating collision assisted Zeeman cooling.

  16. Performance of painted plywood and cloth Nzi traps relative to Manitoba and greenhead traps for tabanids and stable flies.

    PubMed

    Mihok, Steve; Carlson, David A

    2007-04-01

    Experiments were conducted to adapt the cloth Nzi trap to a format suitable for fixed applications in biting fly sampling or control. Catches of tabanids [Tabanus L., Chrysops (Meigen), and Hybomitra Enderlein], and stable flies [Stomoxys calcitrans (L.)] in painted plywood traps were compared with those in standard phthalogen blue cloth traps, and in similarly painted cloth traps. The Manitoba horse fly trap and the Tabanus nigrovittatus Macquart "greenhead" box trap were used as additional standards during one tabanid season. Shiny features of traps reduced catches, e.g., paint on cloth instead of wood, or use of aluminum screening instead of netting. Nevertheless, appropriately painted plywood Nzi traps caught as many biting flies as did standard cloth Nzi traps, if paint finishes were matte, and with the use of phthalogen blue colorants. Nzi traps collected about the same tabanid fauna as the Manitoba and T. nigrovittatus traps, but with improved catches of Chrysops and Tabanus. Recommendations are provided on appropriate color matching, and selection of readily-available materials for trap construction.

  17. Linear Ion Trap for the Mars Organic Molecule Analyzer

    NASA Astrophysics Data System (ADS)

    Brinckerhoff, William; Arevalo, Ricardo; Danell, Ryan; van Amerom, Friso; Pinnick, Veronica; Li, Xiang; Hovmand, Lars; Getty, Stephanie; Mahaffy, Paul; Goesmann, Fred; Steininger, Harald

    2014-05-01

    The 2018 ExoMars rover mission includes the Mars Organic Molecule Analyzer (MOMA) investigation. MOMA will examine the chemical composition of samples acquired from depths of up to two meters below the martian surface, where organics may be protected from radiative and oxidative degradation. When combined with the complement of instruments in the rover's Pasteur Payload, MOMA has the potential to reveal the presence of a wide range of organics preserved in a variety of mineralogical environments, and to begin to understand the structural character and potential origin of those compounds. MOMA includes a linear, or 2D, ion trap mass spectrometer (ITMS) that is designed to analyze molecular composition of (i) gas evolved from pyrolyzed powder samples and separated on a gas chromatograph and (ii) ions directly desorbed from solid samples at Mars ambient pressure using a pulsed laser and a fast-valve capillary ion inlet system. This "dual source" approach gives MOMA unprecedented breadth of detection over a wide range of molecular weights and volatilities. Analysis of nonvolatile, higher-molecular weight organics such as carboxylic acids and peptides even in the presence of significant perchlorate concentrations is enabled by the extremely short (~1 ns) pulses of the desorption laser. Use of the ion trap's tandem mass spectrometry mode permits selective focus on key species for isolation and controlled fragmentation, providing structural analysis capabilities. The flight-like engineering test unit (ETU) of the ITMS, now under construction, will be used to verify breadboard performance with high fidelity, while simultaneously supporting the development of analytical scripts and spectral libraries using synthetic and natural Mars analog samples guided by current results from MSL. ETU campaign data will strongly advise the specifics of the calibration applied to the MOMA flight model as well as the science operational procedures during the mission.

  18. Tandem robot control system and method for controlling mobile robots in tandem

    DOEpatents

    Hayward, David R.; Buttz, James H.; Shirey, David L.

    2002-01-01

    A control system for controlling mobile robots provides a way to control mobile robots, connected in tandem with coupling devices, to navigate across difficult terrain or in closed spaces. The mobile robots can be controlled cooperatively as a coupled system in linked mode or controlled individually as separate robots.

  19. SYMTRAN - A Time-dependent Symmetric Tandem Mirror Transport Code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hua, D; Fowler, T

    2004-06-15

    A time-dependent version of the steady-state radial transport model in symmetric tandem mirrors in Ref. [1] has been coded up and first tests performed. Our code, named SYMTRAN, is an adaptation of the earlier SPHERE code for spheromaks, now modified for tandem mirror physics. Motivated by Post's new concept of kinetic stabilization of symmetric mirrors, it is an extension of the earlier TAMRAC rate-equation code omitting radial transport [2], which successfully accounted for experimental results in TMX. The SYMTRAN code differs from the earlier tandem mirror radial transport code TMT in that our code is focused on axisymmetric tandem mirrorsmore » and classical diffusion, whereas TMT emphasized non-ambipolar transport in TMX and MFTF-B due to yin-yang plugs and non-symmetric transitions between the plugs and axisymmetric center cell. Both codes exhibit interesting but different non-linear behavior.« less

  20. Steam trap monitor

    DOEpatents

    Ryan, Michael J.

    1988-01-01

    A steam trap monitor positioned downstream of a steam trap in a closed steam system includes a first sensor (the combination of a hot finger and thermocouple well) for measuring the energy of condensate and a second sensor (a cold finger) for measuring the total energy of condensate and steam in the line. The hot finger includes one or more thermocouples for detecting condensate level and energy, while the cold finger contains a liquid with a lower boiling temperature than that of water. Vapor pressure from the liquid is used to do work such as displacing a piston or bellows in providing an indication of total energy (steam+condensate) of the system. Processing means coupled to and responsive to outputs from the thermocouple well hot and cold fingers subtracts the condensate energy as measured by the hot finger and thermocouple well from the total energy as measured by the cold finger to provide an indication of the presence of steam downstream from the trap indicating that the steam trap is malfunctioning.

  1. The mechanical design and simulation of a scaled H⁻ Penning ion source.

    PubMed

    Rutter, T; Faircloth, D; Turner, D; Lawrie, S

    2016-02-01

    The existing ISIS Penning H(-) source is unable to produce the beam parameters required for the front end test stand and so a new, high duty factor, high brightness scaled source is being developed. This paper details first the development of an electrically biased aperture plate for the existing ISIS source and second, the design, simulation, and development of a prototype scaled source.

  2. The mechanical design and simulation of a scaled H- Penning ion source

    NASA Astrophysics Data System (ADS)

    Rutter, T.; Faircloth, D.; Turner, D.; Lawrie, S.

    2016-02-01

    The existing ISIS Penning H- source is unable to produce the beam parameters required for the front end test stand and so a new, high duty factor, high brightness scaled source is being developed. This paper details first the development of an electrically biased aperture plate for the existing ISIS source and second, the design, simulation, and development of a prototype scaled source.

  3. Spatial mismatch between sea lamprey behaviour and trap location explains low success at trapping for control

    USGS Publications Warehouse

    Rous, Andrew M.; McLean, Adrienne R.; Barber, Jessica; Bravener, Gale; Castro-Santos, Theodore; Holbrook, Christopher M.; Imre, Istvan; Pratt, Thomas C.; McLaughlin, Robert L.

    2017-01-01

    Crucial to the management of invasive species is understanding space use and the environmental features affecting space use. Improved understanding of space use by invasive sea lamprey (Petromyzon marinus) could help researchers discern why trap success in large rivers is lower than needed for effective control. We tested whether manipulating discharge nightly could increase trap success at a hydroelectric generating station on the St. Marys River. We quantified numbers of acoustically tagged sea lampreys migrating up to, and their space use at, the hydroelectric generating station. In 2011 and 2012, 78% and 68%, respectively, of tagged sea lampreys reached the generating station. Sea lampreys were active along the face, but more likely to occur at the bottom and away from the traps near the surface, especially when discharge was high. Our findings suggest that a low probability of encountering traps was due to spatial (vertical) mismatch between space use by sea lamprey and trap locations and that increasing discharge did not alter space use in ways that increased trap encounter. Understanding space use by invasive species can help managers assess the efficacy of trapping and ways of improving trapping success.

  4. Universal collisional activation ion trap mass spectrometry

    DOEpatents

    McLuckey, S.A.; Goeringer, D.E.; Glish, G.L.

    1993-04-27

    A universal collisional activation ion trap comprises an ion trapping means containing a bath gas and having connected thereto a noise signal generator. A method of operating a universal collisional activation ion trap comprises the steps of: providing an ion trapping means; introducing into the ion trapping means a bath gas; and, generating a noise signal within the ion trapping means; introducing into the ion trapping means a substance that, when acted upon by the noise signal, undergoes collisional activation to form product ions.

  5. Universal collisional activation ion trap mass spectrometry

    DOEpatents

    McLuckey, Scott A.; Goeringer, Douglas E.; Glish, Gary L.

    1993-01-01

    A universal collisional activation ion trap comprises an ion trapping means containing a bath gas and having connected thereto a noise signal generator. A method of operating a universal collisional activation ion trap comprises the steps of: providing an ion trapping means; introducing into the ion trapping means a bath gas; and, generating a noise signal within the ion trapping means; introducing into the ion trapping means a substance that, when acted upon by the noise signal, undergoes collisional activation to form product ions.

  6. Comparison of utilization, cost, adherence, and hypoglycemia in patients with type 2 diabetes initiating rapid-acting insulin analog with prefilled pen versus vial/syringe.

    PubMed

    Lee, Lauren J; Li, Qian; Reynolds, Matthew W; Pawaskar, Manjiri D; Corrigan, Sheila M

    2011-01-01

    Studies examining outcomes of different insulin delivery systems are limited. The objective of this study was to compare healthcare utilization, costs, adherence, and hypoglycemia rates in patients with type 2 diabetes mellitus (T2DM) initiating rapid-acting insulin analog (RAIA) using prefilled pen versus vial/syringe. A retrospective analysis was conducted using a US claims database (1/1/2007 to 12/31/2008). Inclusion criteria were: ≥18 years old, with T2DM, ≥12 months of continuous eligibility, and new to RAIA. Difference-in-difference analyses after propensity score matching were conducted to compare changes in outcomes from 6 months prior to and 6 months after initiating RAIA with a prefilled pen versus vial/syringe (Wilcoxon rank-sum test for costs and t-test for other outcomes). Categories of utilization and costs (2009 USD) included total and diabetes-related inpatient, outpatient, and emergency room. Adherence was measured by proportion of days covered (PDC). Hypoglycemia was identified using ICD-9-CM codes. Baseline characteristics were similar between the prefilled pen (n = 239) and vial/syringe (n = 590) cohorts after matching. Adherence to RAIA was greater in the prefilled pen cohort than the vial/syringe cohort (PDC: 54.6 vs. 45.2%, p < 0.001). While the increase in diabetes-related pharmacy costs from before to after initiating RAIA was greater in the prefilled pen cohort than the vial/syringe cohort (+$900 vs. +$607, p < 0.001), the prefilled pen cohort was associated with greater reductions in the total diabetes-related costs (-$235 vs. +$61, p = 0.006) and the utilization of oral anti-hyperglycemic agents (-1.3 vs. -0.7, p = 0.016). There were no significant differences in other outcomes. Claims databases do not provide optimal measures for adherence or T2DM severity, and only capture hypoglycemia events requiring clinical intervention. Initiating RAIA with a prefilled pen was associated with better adherence and

  7. Ease of Use of the Insulin Glargine 300 U/mL Pen Injector in Insulin-Naïve People With Type 2 Diabetes.

    PubMed

    Pohlmeier, Harald; Berard, Lori; Brulle-Wohlhueter, Claire; Wu, Junlong; Dahmen, Raphael; Nowotny, Irene; Klonoff, David

    2017-03-01

    Insulin glargine 300 U/mL (Gla-300) contains the same active ingredient as glargine 100 U/mL (Gla-100), and provides the same number of units in one-third of the volume. The SoloSTAR ® injector pen has been modified to ensure accurate administration of this reduced volume and to improve user experience. Insulin- and pen-naïve adults with type 2 diabetes (T2DM) inadequately controlled with oral antihyperglycemic drugs, who had glycated hemoglobin (HbA1c) levels of 7.0-11.0 % (53-97 mmol/mol) were studied. They received once-daily Gla-300 in this 4-week, multicenter, open-label, single-arm study (NCT02227212). Ease of use/ease of learning (the primary endpoint), glycemic control, safety, and reliability of the disposable (prefilled) Gla-300 injector pen (secondary endpoints) were evaluated. At week 4, 95.0% of 40 participating subjects assessed the pen as excellent/good and none as poor/very poor; 97.5% would recommend it to others. Total Diabetes Treatment Satisfaction Questionnaire scores were stable throughout the study. Mean (SD) fasting plasma glucose levels decreased from 166.1 (35.0) mg/dL at baseline to 124.2 (41.1) mg/dL at week 4. No product technical complaints (PTCs) or adverse events (AEs) related to PTCs were reported. The number of subjects experiencing hypoglycemic events of any kind and the incidence of AEs were low. No serious AEs were reported. The Gla-300 injector pen is easy to use and easy to learn to use, with demonstrable reliability and high degrees of acceptance and treatment satisfaction. Once-daily Gla-300 basal insulin treatment was well tolerated and effective in pen- and insulin-naïve adult T2DM subjects.

  8. Precision Tests of the Electroweak Interaction using Trapped Atoms and Ions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Melconian, Daniel George

    The objective of the proposed research is to study fundamental aspects of the electroweak interaction via precision measurements in beta decay to test our current understanding of fundamental particles and forces as contained in the so-called "Standard Model" of particle physics. By comparing elegant experiments to rigorous theoretical predictions, we will either confirm the Standard Model to a higher degree and rule out models which seek to extend it, or find evidence of new physics and help guide theorists in developing the New Standard Model. The use of ion and neutral atom traps at radioactive ion beam facilities has openedmore » up a new vista in precision low-energy nuclear physics experiments. Traps provide an ideal source of decaying atoms: they can be extremely cold (~1 mK); they are compact (~1 mm^3); and perhaps most importantly, the daughter particles escape with negligible distortions to their momenta in a scattering-free, open environment. The project is taking advantage of these technologies and applying them to precision beta-decay studies at radioactive beam facilities. The program consists of two complementary efforts: 1) Ion traps are an extremely versatile tool for purifying, cooling and bunching low-energy beams of short-lived nuclei. A large-bore (210~mm) superconducting 7-Tesla solenoid is at the heart of a Penning trap system for which there is a dedicated beamline at T-REX, the upgraded radioactive beam facility at the Cyclotron Institute, Texas A&M University. In addition to providing a general-purpose decay station, the flagship program for this system is measuring the ft-values and beta-neutrino correlation parameters from isospin T=2 superallowed beta-delayed proton decays, complimenting and expanding the already strong program in fundamental interactions at the Institute. 2) A magneto-optical trap is being used at the TRIUMF Neutral Atom Trap facility to observe the (un)polarized angular distribution parameters of isotopes of

  9. Measuring out-of-time-order correlations and multiple quantum spectra in a trapped-ion quantum magnet

    NASA Astrophysics Data System (ADS)

    Gärttner, Martin; Bohnet, Justin G.; Safavi-Naini, Arghavan; Wall, Michael L.; Bollinger, John J.; Rey, Ana Maria

    2017-08-01

    Controllable arrays of ions and ultracold atoms can simulate complex many-body phenomena and may provide insights into unsolved problems in modern science. To this end, experimentally feasible protocols for quantifying the buildup of quantum correlations and coherence are needed, as performing full state tomography does not scale favourably with the number of particles. Here we develop and experimentally demonstrate such a protocol, which uses time reversal of the many-body dynamics to measure out-of-time-order correlation functions (OTOCs) in a long-range Ising spin quantum simulator with more than 100 ions in a Penning trap. By measuring a family of OTOCs as a function of a tunable parameter we obtain fine-grained information about the state of the system encoded in the multiple quantum coherence spectrum, extract the quantum state purity, and demonstrate the buildup of up to 8-body correlations. Future applications of this protocol could enable studies of many-body localization, quantum phase transitions, and tests of the holographic duality between quantum and gravitational systems.

  10. Extensions in Pen Ink Dosimetry: Ultraviolet Calibration Applications for Primary and Secondary Schools

    ERIC Educational Resources Information Center

    Downs, Nathan; Parisi, Alfio; Powell, Samantha; Turner, Joanna; Brennan, Chris

    2010-01-01

    A technique has previously been described for secondary school-aged children to make ultraviolet (UV) dosimeters from highlighter pen ink drawn onto strips of paper. This technique required digital comparison of exposed ink paper strips with unexposed ink paper strips to determine a simple calibration function relating the degree of ink fading to…

  11. Use of model super-shedders to define the role of pen floor and hide contamination in the transmission of Escherichia coli O157:H7.

    PubMed

    Stanford, K; Stephens, T P; McAllister, T A

    2011-01-01

    Super-shedders, cattle shedding at least 10(4) cfu of Escherichia coli O157:H7 per gram of feces, increase the risks of contaminating the food chain and disseminating the organism through cattle populations. Because detecting super-shedders in cattle populations is laborious and time-consuming, a study was conducted to evaluate the role of hide and pen-floor contamination by model super shedders (MSS) in transmission of E. coli O157:H7. Steers (n = 48) negative for E. coli O157:H7 were allocated to 6 pens, with 2 replicate pens per treatment. Treatment A consisted of 3,000 g of feces inoculated with 10(6) cfu/g of a 5-strain mixture of nalidixic acid-resistant E. coli O157:H7 and spread in simulated fecal pats on the pen floor for d 0 through 4 and d 14 through 18. For treatment B, 100 g of the feces per day was spread on the perineum of 1 MSS per pen, and the remaining feces was placed on the pen floor as fecal pats similar to treatment A. Treatment C differed from B in that 50 g of feces was spread on the perineum and 50 g on the brisket of the MSS steer. Fecal samples, perineal swabs (500-cm(2) area around the anus), freshly voided fecal pats and manila rope samples were collected during a 56-d experimental period. More positive rope samples were found in treatments B and C compared with A (P = 0.05), and steers within treatments B and C were 1.3 times more likely (P = 0.05) to shed E. coli O157:H7 in their feces than steers in treatment A. Even though the number of E. coli O157:H7 introduced into pens was similar, results indicate an increased importance of hide compared with pen-floor contamination for transmission of this organism to cattle. Because cattle within treatment B were persistently colonized with E. coli O157:H7, this design should prove suitable for future studies investigating the role of super-shedders in the transmission of E. coli O157:H7.

  12. Cooperative cell motility during tandem locomotion of amoeboid cells

    PubMed Central

    Bastounis, Effie; Álvarez-González, Begoña; del Álamo, Juan C.; Lasheras, Juan C.; Firtel, Richard A.

    2016-01-01

    Streams of migratory cells are initiated by the formation of tandem pairs of cells connected head to tail to which other cells subsequently adhere. The mechanisms regulating the transition from single to streaming cell migration remain elusive, although several molecules have been suggested to be involved. In this work, we investigate the mechanics of the locomotion of Dictyostelium tandem pairs by analyzing the spatiotemporal evolution of their traction adhesions (TAs). We find that in migrating wild-type tandem pairs, each cell exerts traction forces on stationary sites (∼80% of the time), and the trailing cell reuses the location of the TAs of the leading cell. Both leading and trailing cells form contractile dipoles and synchronize the formation of new frontal TAs with ∼54-s time delay. Cells not expressing the lectin discoidin I or moving on discoidin I–coated substrata form fewer tandems, but the trailing cell still reuses the locations of the TAs of the leading cell, suggesting that discoidin I is not responsible for a possible chemically driven synchronization process. The migration dynamics of the tandems indicate that their TAs’ reuse results from the mechanical synchronization of the leading and trailing cells’ protrusions and retractions (motility cycles) aided by the cell–cell adhesions. PMID:26912787

  13. Effect of bait in live trapping Peromyscus

    USGS Publications Warehouse

    Stickel, L.F.

    1948-01-01

    SUMMARY: Evidence from live trapping tests indicated that Peromyscus leucopus did not leave their home ranges because of the attraction of trap bait in nearby areas. A trap line down the center of a heavily live-trapped area caught as many mice before the area trapping as afterward. Thus, there was reason to believe that the area trapping did not serve to pre-bait the mice. Two unbaited lines of live traps caught an equal number of Peromyscus. When one line was baited with rolled oats and peanut butter the efficiency of the traps was improved to the extent that the baited line captured more than twice as many mice as the unbaited line. It is concluded that for the species and habitat tested it is safe to make population calculations based on the assumption that the animals remain within their home ranges and do not tend to move into the trapped area because of the attraction of the trap bait.

  14. DNA Damage by Ionizing Radiation: Tandem Double Lesions by Charged Particles

    NASA Technical Reports Server (NTRS)

    Huo, Winifred M.; Chaban, Galina M.; Wang, Dunyou; Dateo, Christopher E.

    2005-01-01

    Oxidative damages by ionizing radiation are the source of radiation-induced carcinogenesis, damage to the central nervous system, lowering of the immune response, as well as other radiation-induced damages to human health. Monte Carlo track simulations and kinetic modeling of radiation damages to the DNA employ available molecular and cellular data to simulate the biological effect of high and low LET radiation io the DNA. While the simulations predict single and double strand breaks and base damages, so far all complex lesions are the result of stochastic coincidence from independent processes. Tandem double lesions have not yet been taken into account. Unlike the standard double lesions that are produced by two separate attacks by charged particles or radicals, tandem double lesions are produced by one single attack. The standard double lesions dominate at the high dosage regime. On the other hand, tandem double lesions do not depend on stochastic coincidences and become important at the low dosage regime of particular interest to NASA. Tandem double lesions by hydroxyl radical attack of guanine in isolated DNA have been reported at a dosage of radiation as low as 10 Gy. The formation of two tandem base lesions was found to be linear with the applied doses, a characteristic of tandem lesions. However, tandem double lesions from attack by a charged particle have not been reported.

  15. Collision-energy-resolved angular distribution of Penning electrons for N 2-He ∗(2 3S)

    NASA Astrophysics Data System (ADS)

    Hanzawa, Yoshinori; Kishimoto, Naoki; Yamazaki, Masakazu; Ohno, Koichi

    2006-07-01

    The collision-energy-resolved angular distributions of Penning electrons for individual ionic state of N 2-He ∗(2 3S) were measured. The angular distributions showed increasing intensity in the backward (rebounding) directions with respect to initial He ∗(2 3S) beam vector because Penning ionization occurs with a collision against repulsive interaction wall followed by the electron emission from 2s orbital of He ∗. We also analyzed internal angular distribution by means of fitting parameters using classical trajectory calculations for N 2-He ∗(2 3S) on the modified interaction potential. These internal angular distributions suggested the electron emission from 2s orbital of He ∗ and they depended on collision energy and electron kinetic energy.

  16. Switching Oxide Traps

    NASA Technical Reports Server (NTRS)

    Oldham, Timothy R.

    2003-01-01

    We consider radiation-induced charge trapping in SiO2 dielectric layers, primarily from the point of view of CMOS devices. However, SiO2 insulators are used in many other ways, and the same defects occur in other contexts. The key studies, which determined the nature of the oxide charge traps, were done primarily on gate oxides in CMOS devices, because that was the main radiation problem in CMOS at one time. There are two major reviews of radiation-induced oxide charge trapping already in the literature, which discuss the subject in far greater detail than is possible here. The first of these was by McLean et al. in 1989, and the second, ten years later, was intended as an update, because of additional, new work that had been reported. Basically, the picture that has emerged is that ionizing radiation creates electron-hole pairs in the oxide, and the electrons have much higher mobility than the holes. Therefore, the electrons are swept out of the oxide very rapidly by any field that is present, leaving behind any holes that escape the initial recombination process. These holes then undergo a polaron hopping transport toward the Si/SiO2 interface (under positive bias). Near the interface, some fraction of them fall into deep, relatively stable, long-lived hole traps. The nature and annealing behavior of these hole traps is the main focus of this paper.

  17. γ-secretase composed of PS1/Pen2/Aph1a can cleave Notch and APP in the absence of Nicastrin

    PubMed Central

    Zhao, Guojun; Liu, Zhenyi; Ilagan, Ma. Xenia G.; Kopan, Raphael

    2010-01-01

    γ-secretase is a multiprotein intramembrane-cleaving protease with a growing list of protein substrates including the Notch receptors and the amyloid precursor protein. The four components of γ-secretase complex - presenilin (PS), nicastrin (NCT), Pen2, and Aph1 - are all thought to be essential for activity. The catalytic domain resides within PS proteins; NCT has been suggested to be critical for substrate recognition; the contributions of Pen2 and Aph1 remain unclear. The role of NCT has been challenged recently by the observation that a critical residue (E332) in NCT, thought to be essential for γ-secretase activity, is instead involved in complex maturation. Here we report that NCT is dispensable for γ-secretase activity. NCT-independent γ-secretase activity can be detected in two independent NCT-deficient MEF lines, and blocked by the γ-secretase inhibitors DAPT and L-685,458. This catalytic activity requires prior ectodomain shedding of the substrate, and can cleave ligand-activated endogenous Notch receptors, indicating presence at the plasma membrane. siRNA knockdown experiments demonstrated that NCT-independent γ-secretase activity requires the presence of PS1, Pen2 and Aph1a but can tolerate knockdown of PS2 or Aph1b. We conclude that a PS1/Pen2/Aph1a trimeric complex is an active enzyme, displaying similar biochemical properties to those of γ-secretase and roughly 50% of its activity when normalized to PS1 NTF levels. This PS1/Pen2/Aph1a complex, however, is highly unstable. Thus, NCT acts to stabilize γ-secretase, but is not required for substrate recognition. PMID:20130175

  18. A tandem mirror hybrid plume plasma propulsion facility

    NASA Technical Reports Server (NTRS)

    Yang, T. F.; Krueger, W. A.; Peng, S.; Urbahn, J.; Chang-Diaz, F. R.

    1988-01-01

    This paper discusses a novel concept in electrodeless plasma propulsion, in which the materials problems are ameliorated by an electrodeless magnetic confinement scheme borrowed from the tandem mirror approach to controlled thermonuclear fusion. The concept also features a two-stage magnetic nozzle with an annular hypersonic coaxial gas injector near the throat. The nozzle produces hybrid plume by the coaxial injection of hypersonic neutral gas, and the gas layer thus formed protects the material walls from the hot plasma and, through increased collisions, helps detach it from the diverging magnetic field. The tandem mirror plasma propulsion facility is capable of delivering a variable I(sp). The results of numerical simulation of this concept are presented together with those from an experimental tandem-mirror plasma propulsion device.

  19. A Scintillation Counter System Design To Detect Antiproton Annihilation using the High Performance Antiproton Trap(HiPAT)

    NASA Technical Reports Server (NTRS)

    Martin, James J.; Lewis, Raymond A.; Stanojev, Boris

    2003-01-01

    The High Performance Antiproton Trap (HiPAT), a system designed to hold up to l0(exp 12) charge particles with a storage half-life of approximately 18 days, is a tool to support basic antimatter research. NASA's interest stems from the energy density represented by the annihilation of matter with antimatter, 10(exp 2)MJ/g. The HiPAT is configured with a Penning-Malmberg style electromagnetic confinement region with field strengths up to 4 Tesla, and 20kV. To date a series of normal matter experiments, using positive and negative ions, have been performed evaluating the designs performance prior to operations with antiprotons. The primary methods of detecting and monitoring stored normal matter ions and antiprotons within the trap includes a destructive extraction technique that makes use of a micro channel plate (MCP) device and a non-destractive radio frequency scheme tuned to key particle frequencies. However, an independent means of detecting stored antiprotons is possible by making use of the actual annihilation products as a unique indicator. The immediate yield of the annihilation event includes photons and pie mesons, emanating spherically from the point of annihilation. To "count" these events, a hardware system of scintillators, discriminators, coincident meters and multi channel scalars (MCS) have been configured to surround much of the HiPAT. Signal coincidence with voting logic is an essential part of this system, necessary to weed out the single cosmic ray events from the multi-particle annihilation shower. This system can be operated in a variety of modes accommodating various conditions. The first is a low-speed sampling interval that monitors the background loss or "evaporation" rate of antiprotons held in the trap during long storage periods; provides an independent method of validating particle lifetimes. The second is a high-speed sample rate accumulating information on a microseconds time-scale; useful when trapped antiparticles are extracted

  20. Biocompatible enzymatic roller pens for direct writing of biocatalytic materials: "do-it-yourself" electrochemical biosensors.

    PubMed

    Bandodkar, Amay J; Jia, Wenzhao; Ramírez, Julian; Wang, Joseph

    2015-06-03

    The development of enzymatic-ink-based roller pens for direct drawing of biocatalytic sensors, in general, and for realizing renewable glucose sensor strips, in particular, is described. The resulting enzymatic-ink pen allows facile fabrication of high-quality inexpensive electrochemical biosensors of any design by the user on a wide variety of surfaces having complex textures with minimal user training. Unlike prefabricated sensors, this approach empowers the end user with the ability of "on-demand" and "on-site" designing and fabricating of biocatalytic sensors to suit their specific requirement. The resulting devices are thus referred to as "do-it-yourself" sensors. The bio-active pens produce highly reproducible biocatalytic traces with minimal edge roughness. The composition of the new enzymatic inks has been optimized for ensuring good biocatalytic activity, electrical conductivity, biocompati-bility, reproducible writing, and surface adherence. The resulting inks are characterized using spectroscopic, viscometric, electrochemical, thermal and microscopic techniques. Applicability to renewable blood glucose testing, epidermal glucose monitoring, and on-leaf phenol detection are demonstrated in connection to glucose oxidase and tyrosinase-based carbon inks. The "do-it-yourself" renewable glucose sensor strips offer a "fresh," reproducible, low-cost biocatalytic sensor surface for each blood test. The ability to directly draw biocatalytic conducting traces even on unconventional surfaces opens up new avenues in various sensing applications in low-resource settings and holds great promise for diverse healthcare, environmental, and defense domains. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.