Gao, Meng; Wang, Yuesheng; Wei, Huizhen; Ouyang, Hui; He, Mingzhen; Zeng, Lianqing; Shen, Fengyun; Guo, Qiang; Rao, Yi
2014-06-01
A method was developed for the determination of amygdalin and its metabolite prunasin in rat plasma after intragastric administration of Maxing shigan decoction. The analytes were identified by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and quantitatively determined by ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry. After purified by liquid-liquid extraction, the qualitative analysis of amygdalin and prunasin in the plasma sample was performed on a Shim-pack XR-ODS III HPLC column (75 mm x 2.0 mm, 1.6 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on a Triple TOF 5600 quadrupole time of flight mass spectrometer. The quantitative analysis of amygdalin and prunasin in the plasma sample was performed by separation on an Agilent C18 HPLC column (50 mm x 2.1 mm, 1.7 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on an AB Q-TRAP 4500 triple quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operated in negative ion mode and multiple-reaction monitoring (MRM) mode. The qualitative analysis results showed that amygdalin and its metabolite prunasin were detected in the plasma sample. The quantitative analysis results showed that the linear range of amygdalin was 1.05-4 200 ng/mL with the correlation coefficient of 0.999 0 and the linear range of prunasin was 1.25-2 490 ng/mL with the correlation coefficient of 0.997 0. The method had a good precision with the relative standard deviations (RSDs) lower than 9.20% and the overall recoveries varied from 82.33% to 95.25%. The limits of detection (LODs) of amygdalin and prunasin were 0.50 ng/mL. With good reproducibility, the method is simple, fast and effective for the qualitative and quantitative analysis of the amygdalin and prunasin in plasma sample of rats which were administered by Maxing shigan decoction.
Yang, Liyu; Amad, Ma'an; Winnik, Witold M; Schoen, Alan E; Schweingruber, Hans; Mylchreest, Iain; Rudewicz, Patrick J
2002-01-01
Triple quadrupole mass spectrometers, when operated in multiple reaction monitoring (MRM) mode, offer a unique combination of sensitivity, specificity, and dynamic range. Consequently, the triple quadrupole is the workhorse for high-throughput quantitation within the pharmaceutical industry. However, in the past, the unit mass resolution of quadrupole instruments has been a limitation when interference from matrix or metabolites cannot be eliminated. With recent advances in instrument design, triple quadrupole instruments now afford mass resolution of less than 0.1 Dalton (Da) full width at half maximum (FWHM). This paper describes the evaluation of an enhanced resolution triple quadrupole mass spectrometer for high-throughput bioanalysis with emphasis on comparison of selectivity, sensitivity, dynamic range, precision, accuracy, and stability under both unit mass (1 Da FWHM) and enhanced (
Depletion of Urinary Zilpaterol Residues in Horses as Measured by ELISA and UPLC-MS/MS
USDA-ARS?s Scientific Manuscript database
Three horses were dosed with dietary zilpaterol and the urine concentration measured from withdrawal day 0 to withdrawal day 21. The analyses were carried out using both enzyme linked immunosorbent assay (ELISA) and an ultra-performance liquid chromatography with triple-quadrupole-tandem mass spect...
USDA-ARS?s Scientific Manuscript database
A method has been developed for screening glyceollins and their metabolites based upon precursor ion scanning. Under higher-energy collision conditions, employing a triple quadrupole mass spectrometer in the negative ion mode, deprotonated glyceollin precursors yield a diagnostic radical product ion...
Xiang, Xiang; Sha, Xiuxiu; Su, Shulan; Zhu, Zhenhua; Guo, Sheng; Yan, Hui; Qian, Dawei; Duan, Jin-Ao
2018-03-01
Salvia miltiorrhiza, a traditional Chinese medicine, is a widely used herbal medicine to treat cardiovascular and cerebrovascular diseases. In this study, ultraviolet (UV)-visible spectrophotometry and ultra-high performance liquid chromatography with triple quadrupole tandem mass spectrometry analytical methods were used for rapid quantification of polysaccharides and 21 nucleosides and amino acids in S. miltiorrhiza to determine 17 samples of different tissues from different areas. Based on the total contents, hierarchical clustering analysis and principal components analysis were performed to classify these samples. The established methods were validated with good linearity, precision, repeatability, stability, and recovery. Chemical analysis revealed a higher content of total analytes in the sample of inflorescence from Nanjing (34.17 mg/g), sample of root and rhizome from Shaanxi (34.13 mg/g) and sample of stem and leaf from Nanjing (31.14 mg/g), respectively, indicating that root and rhizome from Shaanxi and the aerial parts from Nanjing exhibited the highest quality due to their highest content. In addition, contents of nucleosides and amino acids in the aerial parts (14.67 mg/g) were much higher than that in roots and rhizomes (9.17 mg/g). This study suggested that UV-visible spectrophotometry and ultra-high performance liquid chromatography with triple quadrupole tandem mass spectrometry are effective techniques to analyze polysaccharides, nucleosides, and amino acids in plants, and they provided valuable information for the development and utilization value of the aerial parts of S. miltiorrhiza. This analysis would also provide useful information for the quality control of S. miltiorrhiza. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
USDA-ARS?s Scientific Manuscript database
An analytical method was developed using ultra performance liquid chromatography-triple quadrupole-tandem mass spectrophotometry (UPLC-TQ-MS/MS) to simultaneously analyze 14 sulfonamides (SA) in six minutes. The instrumental detection limit based on signal-to-noise ratio (S/N) > 3, was below 1 pg/µL...
USDA-ARS?s Scientific Manuscript database
An analytical method was developed using ultra performance liquid chromatography-triple quadrupole-tandem mass spectrometry (UPLC-TQ-MS/MS) to simultaneously analyze 14 sulfonamides (SA) in six minutes. Despite the rapidity of the assay the system was properly re-equilibrated in this time. No carryo...
Chen, Xiao-Jun; Meng, Zhi-Yuan; Ren, Li; Song, Yue-Yi; Ren, Ya-Jun; Chen, Jian-Shu; Guan, Ling-Jun
2018-05-01
With the purpose of guaranteeing the safe use of spirotetramat and preventing its potential health threats to consumers, a QuEChERS extraction method coupled with LC triple-quadrupole tandem MS was applied in this study to determine residual spirotetramat metabolites in different tissues of amaranth (Amaranthus tricolor) and in soil. The results indicate that the spirotetramat degraded into different types of metabolites that were located in different tissues of amaranth and in soil. B-keto, B-glu, and B-enol were the three most representative degradation products in the leaf of amaranth, and B-glu and B-enol were the two major degradation products found in the stem of amaranth; however, only B-enol was detected in the root of amaranth. B-keto and B-mono were the two products detected in the soil in which the amaranth grew. The cytotoxicity results demonstrate that spirotetramat and its metabolite B-enol inhibited cellular growth, and the toxicity of spirotetramat and its metabolite B-enol exceeded than that of the metabolites B-keto, B-mono, and B-glu. This investigation is of great significance to the safe use of spirotetramat in agriculture.
Zhou, Guisheng; Pang, Hanqing; Tang, Yuping; Yao, Xin; Mo, Xuan; Zhu, Shaoqing; Guo, Sheng; Qian, Dawei; Qian, Yefei; Su, Shulan; Zhang, Li; Jin, Chun; Qin, Yong; Duan, Jin-ao
2013-05-01
This work presented a new analytical methodology based on hydrophilic interaction ultra-performance liquid chromatography coupled with triple-quadrupole tandem mass spectrometry in multiple-reaction monitoring mode for analysis of 24 underivatized free amino acids (FAAs) in functional foods. The proposed method was first reported and validated by assessing the matrix effects, linearity, limit of detections and limit of quantifications, precision, repeatability, stability and recovery of all target compounds, and it was used to determine the nutritional substances of FAAs in ginkgo seeds and further elucidate the nutritional value of this functional food. The result showed that ginkgo seed turned out to be a good source of FAAs with high levels of several essential FAAs and to have a good nutritional value. Furthermore, the principal component analysis was performed to classify the ginkgo seed samples on the basis of 24 FAAs. As a result, the samples could be mainly clustered into three groups, which were similar to areas classification. Overall, the presented method would be useful for the investigation of amino acids in edible plants and agricultural products.
García-Bermejo, Ángel; Mohr, Susana; Herrero, Laura; González, María-José; Gómara, Belén
2016-09-28
This paper reports on the optimization, characterization, and applicability of gas chromatography coupled to triple-quadrupole tandem mass spectrometry (GC-QqQ(MS/MS)) for the determination of 14 polybrominated diphenylethers (PBDEs) and 2 emerging brominated flame retardants, 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE) and decabromodiphenylethane (DBDPE), in functional food samples. The method showed satisfactory precision and linearity with instrumental limits of detection (iLODs) ranging from 0.12 to 7.1 pg, for tri- to octa-BDEs and BTBPE, and equal to 51 and 20 pg for BDE-209 and DBDPE, respectively. The highest ΣBFR concentrations were found in fish oil supplements (924 pg/g fresh weight, fw), followed by biscuits (90 pg/g fw), vegetable oil supplements (46 pg/g fw), chicken eggs (45 pg/g fw), cow's milk (7.7 pg/g fw), and soy products (1.6 pg/g fw). BDE-47, BDE-99, and DBDPE were the most abundant compounds. Foodstuffs enriched with omega-3 presented concentrations similar to or even lower than those of conventional foods commercialized in Spain since 2000.
Grande-Martínez, Ángel; Arrebola, Francisco Javier; Moreno, Laura Díaz; Vidal, José Luis Martínez; Frenich, Antonia Garrido
2015-01-01
A rapid and sensitive multiresidue method was developed and validated for the determination of around 100 pesticides in dry samples (rice and wheat flour) by ultra-performance LC coupled to a triple quadrupole mass analyzer working in tandem mode (UPLC/QqQ-MS/MS). The sample preparation step was optimized for both matrixes. Pesticides were extracted from rice samples using aqueous ethyl acetate, while aqueous acetonitrile extraction [modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) method] was used for wheat flour matrixes. In both cases the extracts were then cleaned up by dispersive solid phase extraction with MgSO4 and primary secondary amine+C18 sorbents. A further cleanup step with Florisil was necessary to remove fat in wheat flour. The method was validated at two concentration levels (3.6 and 40 μg/kg for most compounds), obtaining recoveries ranging from 70 to 120%, intraday and interday precision values≤20% expressed as RSDs, and expanded uncertainty values≤50%. The LOQ values ranged between 3.6 and 20 μg/kg, although it was set at 3.6 μg/kg for the majority of the pesticides. The method was applied to the analysis of 20 real samples, and no pesticides were detected.
Gwak, Seongshin; Arroyo-Mora, Luis E; Almirall, José R
2015-02-01
Designer drugs are analogues or derivatives of illicit drugs with a modification of their chemical structure in order to circumvent current legislation for controlled substances. Designer drugs of abuse have increased dramatically in popularity all over the world for the past couple of years. Currently, the qualitative seized-drug analysis is mainly performed by gas chromatography-electron ionization-mass spectrometry (GC-EI-MS) in which most of these emerging designer drug derivatives are extensively fragmented not presenting a molecular ion in their mass spectra. The absence of molecular ion and/or similar fragmentation pattern among these derivatives may cause the equivocal identification of unknown seized-substances. In this study, the qualitative identification of 34 designer drugs, mainly synthetic cannabinoids and synthetic cathinones, were performed by gas chromatography-triple quadrupole-tandem mass spectrometry with two different ionization techniques, including electron ionization (EI) and chemical ionization (CI) only focusing on qualitative seized-drug analysis, not from the toxicological point of view. The implementation of CI source facilitates the determination of molecular mass and the identification of seized designer drugs. Developed multiple reaction monitoring (MRM) mode may increase sensitivity and selectivity in the analysis of seized designer drugs. In addition, CI mass spectra and MRM mass spectra of these designer drug derivatives can be used as a potential supplemental database along with EI mass spectral database. Copyright © 2014 John Wiley & Sons, Ltd.
Tian, Tingting; Jin, Yiran; Ma, Yinghua; Xie, Weiwei; Xu, Huijun; Du, Yingfeng
2016-02-01
An ultra performance liquid chromatography coupled with a triple quadrupole electrospray tandem mass spectrometry (UPLC-MS-MS) method was developed for analyzing and identifying the constituents of 11 compounds including berberine, epiberberine, berberrubine, jatrorrhizine, coptisine, palmatine, evodiamine, rutaecarpine, limonin, paeoniflorin and albiflorin in Wuji pill (WJ pill), a traditional Chinese medicine. The chromatographic separation was performed on a C18 column and the mobile phase was composed of water (0.1% formic acid and 2 mmol ammonium acetate) and methanol with a linear gradient elution. The detection was performed by multiple reaction monitoring mode, using electrospray ionization in the positive ion mode. The total run time was 14 min. The calibration curves were linear with all correlation coefficients higher than 0.9987 in the tested range. The intra- and interday precisions were no more than 4.9%, and the average recoveries were from 92.4 to 107.8% with the relative standard deviations no more than 7.8%. The developed method was successfully employed to analyze five batches of WJ pill samples. This is the first time to establish a method for the quality control of WJ pill to ensure the safety and efficacy in clinical applications effectively. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Boes, Kelsey S.; Roberts, Michael S.; Vinueza, Nelson R.
2018-03-01
Complex mixture analysis is a costly and time-consuming task facing researchers with foci as varied as food science and fuel analysis. When faced with the task of quantifying oxygen-rich bio-oil molecules in a complex diesel mixture, we asked whether complex mixtures could be qualitatively and quantitatively analyzed on a single mass spectrometer with mid-range resolving power without the use of lengthy separations. To answer this question, we developed and evaluated a quantitation method that eliminated chromatography steps and expanded the use of quadrupole-time-of-flight mass spectrometry from primarily qualitative to quantitative as well. To account for mixture complexity, the method employed an ionization dopant, targeted tandem mass spectrometry, and an internal standard. This combination of three techniques achieved reliable quantitation of oxygen-rich eugenol in diesel from 300 to 2500 ng/mL with sufficient linearity (R2 = 0.97 ± 0.01) and excellent accuracy (percent error = 0% ± 5). To understand the limitations of the method, it was compared to quantitation attained on a triple quadrupole mass spectrometer, the gold standard for quantitation. The triple quadrupole quantified eugenol from 50 to 2500 ng/mL with stronger linearity (R2 = 0.996 ± 0.003) than the quadrupole-time-of-flight and comparable accuracy (percent error = 4% ± 5). This demonstrates that a quadrupole-time-of-flight can be used for not only qualitative analysis but also targeted quantitation of oxygen-rich lignin molecules in complex mixtures without extensive sample preparation. The rapid and cost-effective method presented here offers new possibilities for bio-oil research, including: (1) allowing for bio-oil studies that demand repetitive analysis as process parameters are changed and (2) making this research accessible to more laboratories. [Figure not available: see fulltext.
NASA Astrophysics Data System (ADS)
Boes, Kelsey S.; Roberts, Michael S.; Vinueza, Nelson R.
2017-12-01
Complex mixture analysis is a costly and time-consuming task facing researchers with foci as varied as food science and fuel analysis. When faced with the task of quantifying oxygen-rich bio-oil molecules in a complex diesel mixture, we asked whether complex mixtures could be qualitatively and quantitatively analyzed on a single mass spectrometer with mid-range resolving power without the use of lengthy separations. To answer this question, we developed and evaluated a quantitation method that eliminated chromatography steps and expanded the use of quadrupole-time-of-flight mass spectrometry from primarily qualitative to quantitative as well. To account for mixture complexity, the method employed an ionization dopant, targeted tandem mass spectrometry, and an internal standard. This combination of three techniques achieved reliable quantitation of oxygen-rich eugenol in diesel from 300 to 2500 ng/mL with sufficient linearity (R2 = 0.97 ± 0.01) and excellent accuracy (percent error = 0% ± 5). To understand the limitations of the method, it was compared to quantitation attained on a triple quadrupole mass spectrometer, the gold standard for quantitation. The triple quadrupole quantified eugenol from 50 to 2500 ng/mL with stronger linearity (R2 = 0.996 ± 0.003) than the quadrupole-time-of-flight and comparable accuracy (percent error = 4% ± 5). This demonstrates that a quadrupole-time-of-flight can be used for not only qualitative analysis but also targeted quantitation of oxygen-rich lignin molecules in complex mixtures without extensive sample preparation. The rapid and cost-effective method presented here offers new possibilities for bio-oil research, including: (1) allowing for bio-oil studies that demand repetitive analysis as process parameters are changed and (2) making this research accessible to more laboratories. [Figure not available: see fulltext.
Boes, Kelsey S; Roberts, Michael S; Vinueza, Nelson R
2018-03-01
Complex mixture analysis is a costly and time-consuming task facing researchers with foci as varied as food science and fuel analysis. When faced with the task of quantifying oxygen-rich bio-oil molecules in a complex diesel mixture, we asked whether complex mixtures could be qualitatively and quantitatively analyzed on a single mass spectrometer with mid-range resolving power without the use of lengthy separations. To answer this question, we developed and evaluated a quantitation method that eliminated chromatography steps and expanded the use of quadrupole-time-of-flight mass spectrometry from primarily qualitative to quantitative as well. To account for mixture complexity, the method employed an ionization dopant, targeted tandem mass spectrometry, and an internal standard. This combination of three techniques achieved reliable quantitation of oxygen-rich eugenol in diesel from 300 to 2500 ng/mL with sufficient linearity (R 2 = 0.97 ± 0.01) and excellent accuracy (percent error = 0% ± 5). To understand the limitations of the method, it was compared to quantitation attained on a triple quadrupole mass spectrometer, the gold standard for quantitation. The triple quadrupole quantified eugenol from 50 to 2500 ng/mL with stronger linearity (R 2 = 0.996 ± 0.003) than the quadrupole-time-of-flight and comparable accuracy (percent error = 4% ± 5). This demonstrates that a quadrupole-time-of-flight can be used for not only qualitative analysis but also targeted quantitation of oxygen-rich lignin molecules in complex mixtures without extensive sample preparation. The rapid and cost-effective method presented here offers new possibilities for bio-oil research, including: (1) allowing for bio-oil studies that demand repetitive analysis as process parameters are changed and (2) making this research accessible to more laboratories. Graphical Abstract ᅟ.
Portolés, T; Sales, C; Abalos, M; Sauló, J; Abad, E
2016-09-21
The use of the novel atmospheric pressure chemical ionization (APCI) source for gas chromatography (GC) coupled to triple quadrupole using tandem mass spectrometry (MS/MS) and its potential for the simultaneous determination of the 12 dioxin-like polychlorobiphenyls (DL-PCBs) in complex food and feed matrices has been evaluated. In first place, ionization and fragmentation behavior of DL-PCBs on the APCI source under charge transfer conditions has been studied followed by their fragmentation in the collision cell. Linearity, repeatability and sensitivity have been studied obtaining instrumental limits of detection and quantification of 0.0025 and 0.005 pg μL(-1) (2.5 and 5 fg on column) respectively for every DL-PCB. Finally, application to real samples has been carried out and DL-PCB congeners (PCB 77, 81, 105, 114, 118, 123, 126, 156, 157, 167, 169, 189) have been detected in the different samples in the range of 0.40-10000 pg g(-1). GC-(APCI)MS/MS has been proved as a suitable alternative to the traditionally accepted confirmation method based on the use of high resolution mass spectrometry and other triple quadrupole tandem mass spectrometry techniques operating with electron ionization. The development of MS/MS methodologies for the analysis of dioxins and DL-PCBs is nowadays particularly important, since this technique was included as a confirmatory method in the present European Union regulations that establish the requirements for the determination of these compounds in food and feed matrices. Copyright © 2016 Elsevier B.V. All rights reserved.
Abad-García, Beatriz; Garmón-Lobato, Sergio; Berrueta, Luis A; Gallo, Blanca; Vicente, Francisca
2009-09-01
A mass spectrometric method using electrospray ionization with triple quadrupole and quadrupole time-of-flight hybrid (Q-Tof) mass spectrometry has been applied to the structural characterization of dihydroflavonols. This family of compounds has been studied by liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the first time in this work. A comprehensive study of the product ion MS spectra of the [M+H](+) ion of a commercially available standard has been performed. The most useful fragmentations in terms of structural identification are those that involve cleavage of the C-ring, resulting in diagnostic ions of dihydroflavonol family: (1,3)A(0) (+), (1,2)B(0) (+), (1,2)B(0) (+)-CO, (0,2)A(0) (+), (0,2)A(0) (+)-H(2)O, (0,2)A(0) (+)-CO, and (0,2)A(0) (+)-H(2)O-CO, that allow the characterization of the substituents in the A- and B-rings. In addition to those ions, other product ions due to losses of H(2)O and CO molecules from the Y(0) (+) ion were observed. Their fragmentation mechanisms and ion structures have been proposed. The established fragmentation patterns have been used to successfully identity three dihydroflavonols found in tangerine juices for the first time. Copyright (c) 2009 John Wiley & Sons, Ltd.
Tölgyessy, P; Nagyová, S; Sládkovičová, M
2017-04-21
A simple, robust, sensitive and environment friendly method for the determination of short chain chlorinated paraffins (SCCPs) in water using stir bar sorptive extraction (SBSE) coupled to thermal desorption-gas chromatography-triple quadrupole tandem mass spectrometry (TD-GC-QqQ-MS/MS) was developed. SBSE was performed using 100mL of water sample, 20mL of methanol as a modifier, and a commercial sorptive stir bar (with 10mm×0.5mm PDMS layer) during extraction period of 16h. After extraction, the sorptive stir bar was thermally desorbed and online analysed by GC-MS/MS. Method performance was evaluated for MilliQ and surface water spiked samples. For both types of matrices, a linear dynamic range of 0.5-3.0μgL -1 with correlation coefficients >0.999 and relative standard deviations (RSDs) of the relative response factors (RRFs) <12% was established. The limits of quantification (LOQs) of 0.06 and 0.08μgL -1 , and the precision (repeatability) of 6.4 and 7.7% (RSDs) were achieved for MilliQ and surface water, respectively. The method also showed good robustness, recovery and accuracy. The obtained performance characteristics indicate that the method is suitable for screening and monitoring and compliance checking with environmental quality standards (EQS, set by the EU) for SCCPs in surface waters. Copyright © 2017 Elsevier B.V. All rights reserved.
Wang, I-Ting Ivy; Cheng, Shu-Fang; Tsai, Shih-Wei
2014-02-21
Synthetic musk is widely used in various scented consumer products. However, the exposure via inhalation is often ignored due to pleasant smells. In addition, the information regarding the distribution of synthetic musk in air is limited. Hence, this research is aimed to develop a highly sensitive and widely applicable method for the determination of airborne synthetic musk. In this study, polyurethane foam (PUF) and filter were employed for active air sampling. Microwave assisted extraction (MAE) and nitrogen evaporator were performed for sample preparation. A gas chromatography coupled with triple quadrupole tandem mass spectrometer (GC/MS-MS) with specific multiple reaction monitoring (MRM) transition pairs was applied for sample analysis. Compared with using selected ion monitoring (SIM) mode traditionally, the sensitivities were improved in this study about an order at least. In terms of air concentration, as low as 0.48ngm(-3) can be determined when sampling at 3.5Lmin(-1) for 8h. The method established was further applied to the analysis of synthetic musk compounds in air samples collected in a cosmetics plant. The results showed that the airborne concentrations of gaseous polycyclic musk, gaseous nitro-musk, and particle-phase polycyclic musk were 6.4×10(2), 4.0×10(1) and 3.1×10(2)ngm(-3), respectively. Meanwhile, Cashmeran, Celstolide, Galaxolide, and Tonalide were found as the dominant musk compounds in the factory investigated. Copyright © 2014 Elsevier B.V. All rights reserved.
High energy collisions on tandem time-of-flight mass spectrometers†
Cotter, Robert J.
2013-01-01
Long before the introduction of matrix-assisted laser desorption (MALDI), electrospray ionization (ESI), Orbitraps and any of the other tools that are now used ubiquitously for proteomics and metabolomics, the highest performance mass spectrometers were sector instruments, providing high resolution mass measurements by combining an electrostatic energy analyzer (E) with a high field magnet (B). In its heyday, the four sector mass spectrometer (or EBEB) was the crown jewel, providing the highest performance tandem mass spectrometry using single, high energy collisions to induce fragmentation. During a time in which quadrupole and tandem triple quadrupole instruments were also enjoying increased usage and popularity, there were nonetheless some clear advantages for sectors over their low collision energy counterparts. Time-of-flight mass spectrometers are high voltage, high vacuum instruments that have much in common with sectors and have inspired the development of tandem instruments exploiting single high energy collisions. In this retrospective we recount our own journey to produce high performance time-of-flights and tandems, describing the basic theory, problems and the advantages for such instruments. An experiment testing impulse collision theory (ICT) underscores the similarities with sector mass spectrometers where this concept was first developed. Applications provide examples of more extensive fragmentation, side chain cleavages and charge-remote fragmentation, also characteristic of high energy sector mass spectrometers. Moreover, the so-called curved-field reflectron has enabled the design of instruments that are simpler, collect and focus all of the ions, and may provide the future technology for the clinic, for tissue imaging and the characterization of microorganisms. PMID:23519928
Peng, Youmei; Cheng, Tiefeng; Dong, Lihong; Zhang, Yuhai; Chen, Xiaojing; Jiang, Jinhua; Zhang, Jingmin; Guo, Xiaohe; Guo, Mintong; Chang, Junbiao; Wang, Qingduan
2014-09-01
2'-Deoxy-2'-β-fluoro-4'-azidocytidine (FNC) is a novel pyrimidine analog that inhibits not only the replication of the hepatitis B virus (HBV), hepatitis C virus (HCV) and HIV but also the replication of lamivudine-resistant HBV, 4'-azidocytidine or 2'-β-methylcytidine-resistant HCV, and nucleoside reverse-transcriptase inhibitor-resistant HIV variants. The present study was undertaken to evaluate the absolute oral bioavailability of FNC in rats and the pharmacokinetic properties of FNC after intragastric administration of single and multiple doses in rats and dogs. A sensitive high-performance liquid chromatography tandem quadrupole time-of-flight mass spectrometry (HPLC/Q-TOF MS) method and a reliable high-performance liquid chromatography tandem triple quadrupole mass spectrometry (HPLC/QqQ MS/MS) method were established for the determination of FNC in the rat and dog plasmas, respectively. The sample preparation involved a protein-precipitation method with methanol after the addition of lamivudine as an internal standard. FNC was analyzed by LC using a YMC-Pack Pro C18 column (150mm×4.6mm, 3μm) with methanol (containing 0.3% formic acid): 10mM ammonium acetate (containing 0.3% formic acid, pH 2.8) (35:65, v/v) as the mobile phase. Both mass spectrometers were equipped with an electrospray ionization interface in the positive-ion mode. The linear range was from 2.00 to 2000.00ngmL(-1) in rat plasma and 0.50 to 400.00ngmL(-1) in dog plasma. The intraday and interday precision were less than 10.55%, and the accuracy was in the range of -5.86 to 5.13%. The mean recoveries were greater than 82.70% and 82.97% for FNC and IS, respectively. The HPLC/Q-TOF MS and HPLC/QqQ MS/MS methods were both successfully applied in the pharmacokinetic studies of FNC in rats and dogs. Copyright © 2014 Elsevier B.V. All rights reserved.
2013-01-01
Background Collision induced dissociation (CID) in the triple quadrupole mass spectrometer system (QQQ) typically yields more abundant fragment ions than those produced with resonance excitation in the presence of helium gas in the ion trap mass spectrometer system (IT). Detailed product ion spectra can be obtained from one stage MS2 scan using the QQQ. In contrast, generating the same number of fragment ions in the ion trap requires multiple stages of fragmentation (MSn) using CID via in-trap resonance excitation with the associated time penalties and drop in sensitivity. Results The use of in-source fragmentation with electrospray ionization (ESI) followed by product ion scan (MS2) in a triple quadrupole mass spectrometer system, was demonstrated. This process enhances the qualitative power of tandem mass spectrometry to simulate the MS3 of ion trap for a comprehensive study of fragmentation mechanisms. A five pharmacologically significant (1Z, 2E)-N-arylpropanehydrazonoyl chlorides (3a-e) were chosen as model compounds for this study. In this work, detailed fragmentation pathways were elucidated by further dissociation of each fragment ion in the ion spectrum, essentially, by incorporating fragmentor voltage induced dissociation (in-source fragmentation) and isolation of fragments in a quadrupole cell Q1. Subsequently, CID occurs in cell, Q2, and fragment ions are analyzed in Q3 operated in product ion mode this process can be referred to as pseudo-MS3 scan mode. Conclusions This approach allowed unambiguous assignment of all fragment ions using tandem mass spectrometer and provided adequate sensitivity and selectivity. It is beneficial for structure determination of unknown trace components. The data presented in this paper provide useful information on the effect of different substituents on the ionization/fragmentation processes and can be used in the characterization of this important class of compounds. PMID:23351484
Kokina, Aija; Pugajeva, Iveta; Bartkevics, Vadims
2016-01-01
A novel and sensitive method utilising high-performance liquid chromatography coupled to triple quadrupole-linear ion trap mass spectrometry (LC-QqQLIT-MS/MS) was developed in order to analyse the content of ochratoxin A (OTA) in coffee samples. The introduction of the triple-stage MS scanning mode (MS(3)) has been shown to increase greatly sensitivity and selectivity by eliminating the high chromatographic baseline caused by interference of complex coffee matrices. The analysis included the sample preparation procedure involving extraction of OTA using a methanol-water mixture and clean-up by immunoaffinity columns and detection using the MS(3) scanning mode of LC-QqQLIT-MS/MS. The proposed method offered a good linear correlation (r(2) > 0.998), excellent precision (RSD < 2.9%) and recovery (94%). The limit of quantification (LOQ) for coffee beans and espresso beverages was 0.010 and 0.003 µg kg(-1), respectively. The developed procedure was compared with traditional methods employing liquid chromatography coupled to fluorescent and tandem quadrupole detectors in conjunction with QuEChERS and solid-phase extraction. The proposed method was successfully applied to the determination of OTA in 15 samples of coffee beans and in 15 samples of espresso coffee beverages obtained from the Latvian market. OTA was found in 10 samples of coffee beans and in two samples of espresso in the ranges of 0.018-1.80 µg kg(-1) and 0.020-0.440 µg l(-1), respectively. No samples exceeded the maximum permitted level of OTA in the European Union (5.0 µg kg(-1)).
Qu, Cheng; Pu, Zong-Jin; Zhou, Gui-Sheng; Wang, Jun; Zhu, Zhen-Hua; Yue, Shi-Jun; Li, Jian-Ping; Shang, Li-Li; Tang, Yu-Ping; Shi, Xu-Qin; Liu, Pei; Guo, Jian-Ming; Sun, Jing; Tang, Zhi-Shu; Zhao, Jing; Zhao, Bu-Chang; Duan, Jin-Ao
2017-09-01
A sensitive, reliable, and powerful ultra-high performance liquid chromatography coupled to triple quadrupole tandem mass spectrometry method was developed for simultaneous quantification of the 15 main bio-active components including phenolic acids and flavonoids within 13 min for the first time. The proposed method was first reported and validated by good linearity (r 2 > 0.9975), limit of detection (1.12-7.01 ng/mL), limit of quantification (3.73-23.37 ng/mL), intra- and inter-day precisions (RSD ≤ 1.92%, RSD ≤ 2.45%), stability (RSD ≤ 5.63%), repeatability (RSD ≤ 4.34%), recovery (96.84-102.12%), and matrix effects (0.92-1.02). The established analytical methodology was successfully applied to comparative analysis of main bio-active components in the herb pair Danshen-Honghua and its single herbs. Compared to the single herb, the content of most flavonoid glycosides was remarkably increased in their herb pair, and main phenolic acids were decreased, conversely. The content changes of the main components in the herb pair supported the synergistic effects on promoting blood circulation and removing blood stasis. The results provide a scientific basis and reference for the quality control of Danshen-Honghua herb pair and the drug interactions based on variation of bio-active components in herb pairs. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Liu, Xin-Guang; Yang, Hua; Cheng, Xiao-Lan; Liu, Lei; Qin, Yong; Wang, Qi; Qi, Lian-Wen; Li, Ping
2014-08-01
Analysis and quality control of Ginkgo biloba have been comprehensively studied. However, little attention has been devoted to the simultaneous extraction and analysis of flavonols and terpene trilactones, especially for direct quantification of flavonol glycosides. This work described a rapid strategy for one-step extraction and quantification of the components. A matrix solid phase dispersion (MSPD) method was designed for the extraction of ginkgo ingredients and compared with the heat-reflux and ultrasonic extraction methods. An ultra-high performance liquid chromatography (UHPLC)-tandem-triple-quadrupole-mass spectrometry (QQQ-MS) method was developed for detection of the 18 components, including 10 original flavonol glycosides, 3 aglycones, and 5 lactones. Subsequently, the proposed strategy was used for the analysis of 12 G. biloba tablets. Results showed that MSPD produced comparable extraction efficiency but consumed less time and required lower solvent volumes compared with conventional methods. Without hydrolysis, the concentration detected was much closer to the original in the sample. The total flavonol glycoside contents in ginkgo tablets ranged from 3.59 to 125.21μgmg(-1), and the terpene trilactone varied from 3.45 to 57.8μgmg(-1) among different manufacturers. In conclusion, the proposed MSPD and UHPLC-QQQ-MS is rapid and sensitive in providing comprehensive profile of chemical constituents especially the genuine flavonol glycosides for improved quality control of ginkgo products. Copyright © 2014 Elsevier B.V. All rights reserved.
Qi, Yulin; Geib, Timon; Schorr, Pascal; Meier, Florian; Volmer, Dietrich A
2015-01-15
Isobaric interferences in human serum can potentially influence the measured concentration levels of 25-hydroxyvitamin D [25(OH)D], when low resolving power liquid chromatography/tandem mass spectrometry (LC/MS/MS) instruments and non-specific MS/MS product ions are employed for analysis. In this study, we provide a detailed characterization of these interferences and a technical solution to reduce the associated systematic errors. Detailed electrospray ionization Fourier transform ion cyclotron resonance (FTICR) high-resolution mass spectrometry (HRMS) experiments were used to characterize co-extracted isobaric components of 25(OH)D from human serum. Differential ion mobility spectrometry (DMS), as a gas-phase ion filter, was implemented on a triple quadrupole mass spectrometer for separation of the isobars. HRMS revealed the presence of multiple isobaric compounds in extracts of human serum for different sample preparation methods. Several of these isobars had the potential to increase the peak areas measured for 25(OH)D on low-resolution MS instruments. A major isobaric component was identified as pentaerythritol oleate, a technical lubricant, which was probably an artifact from the analytical instrumentation. DMS was able to remove several of these isobars prior to MS/MS, when implemented on the low-resolution triple quadrupole mass spectrometer. It was shown in this proof-of-concept study that DMS-MS has the potential to significantly decrease systematic errors, and thus improve accuracy of vitamin D measurements using LC/MS/MS. Copyright © 2014 John Wiley & Sons, Ltd.
Touriño, Sonia; Fuguet, Elisabet; Jáuregui, Olga; Saura-Calixto, Fulgencio; Cascante, Marta; Torres, Josep Lluís
2008-11-01
Grape antioxidant dietary fiber (GADF) is a dietary supplement that combines the benefits of both fiber and antioxidants that help prevent cancer and cardiovascular diseases. The antioxidant polyphenolic components in GADF probably help prevent cancer in the digestive tract, where they are bioavailable. Mass spectrometry coupled to liquid chromatography is a powerful tool for the analysis of complex plant derivatives such as GADF. We use a combination of MS techniques, namely liquid chromatography/electrospray ionization time-of-flight mass spectrometry (LC/ESI-TOF-MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) on a triple quadrupole, for the identification of the polyphenolic constituents of the soluble fraction of GADF. First, we separated the mixture into four fractions which were tested for phenolic constituents using the TOF system in the full scan mode. The high sensitivity and resolution of the TOF detector over the triple quadrupole facilitate the preliminary characterization of the fractions. Then we used LC/ESI-MS/MS to identify the individual phenols through MS/MS experiments (product ion scan, neutral loss scan, precursor ion scan). Finally, most of the identities were unequivocally confirmed by accurate mass measurements on the TOF spectrometer. LC/ESI-TOF-MS combined with MS/MS correctly identifies the bioactive polyphenolic components from the soluble fraction of GADF. High-resolution TOF-MS is particularly useful for identifying the structure of compounds with the same LC/ESI-MS/MS fragmentation patterns.
Kennedy, Joseph H; Wiseman, Justin M
2010-02-01
The present work describes the methodology and investigates the performance of desorption electrospray ionization (DESI) combined with a triple quadrupole mass spectrometer for the quantitation of small drug molecules in human plasma. Amoxepine, atenolol, carbamazepine, clozapine, prazosin, propranolol and verapamil were selected as target analytes while terfenadine was selected as the internal standard common to each of the analytes. Protein precipitation of human plasma using acetonitrile was utilized for all samples. Limits of detection were determined for all analytes in plasma and shown to be in the range 0.2-40 ng/mL. Quantitative analysis of amoxepine, prazosin and verapamil was performed over the range 20-7400 ng/mL and shown to be linear in all cases with R(2) >0.99. In most cases, the precision (relative standard deviation) and accuracy (relative error) of each method were less than or equal to 20%, respectively. The performance of the combined techniques made it possible to analyze each sample in 15 s illustrating DESI tandem mass spectrometry (MS/MS) as powerful tool for the quantitation of analytes in deproteinized human plasma. Copyright 2010 John Wiley & Sons, Ltd.
Kuwayama, Kenji; Miyaguchi, Hajime; Yamamuro, Tadashi; Tsujikawa, Kenji; Kanamori, Tatsuyuki; Iwata, Yuko T; Inoue, Hiroyuki
2015-11-30
A primary metabolite of Δ(9) -tetrahydrocannabinol, 11-nor-9-carboxytetrahydrocannabinol (THC-COOH), serves as an effective indicator for cannabis intake. According to the recommendations of the Society of Hair Testing, at least 0.2 pg/mg of THC-COOH (cut-off level) must be present in a hair sample to constitute a positive result in a drug test. Typically, hair is digested with an alkaline solution and is subjected to gas chromatography/tandem mass spectrometry (GC/MS/MS) with negative ion chemical ionization (NICI). It is difficult to quantify THC-COOH at the cut-off level using liquid chromatography/tandem mass spectrometry (LC/MS/MS) without acquisition of second-generation product ions in triple quadrupole-ion trap mass spectrometers, because large amounts of matrix components in the low-mass range produced by digestion interfere with the THC-COOH peak. Using the typical pretreatment method (alkaline dissolution) and micro-pulverized extraction (MPE) with a stainless bullet, we compared the quantification of THC-COOH using GC/MS/MS and LC/MS/MS. MPE reduced the amount of matrix components in the low-mass range and enabled the quantification of THC-COOH at 0.2 pg/mg using a conventional triple quadrupole liquid chromatograph coupled to a mass spectrometer. On the other hand, the MPE pretreatment was unsuitable for GC/MS/MS, probably due to matrix components in the high-mass range. The proper combination of pretreatments and instrumental analyses was shown to be important for detecting trace amounts of THC-COOH in hair. In MPE, samples can be prepared rapidly, and LC/MS/MS is readily available, unlike GC/MS/MS with NICI. The combination of MPE and LC/MS/MS might therefore be used in the initial screening for THC-COOH in hair prior to confirmatory analysis using GC/MS/MS with NICI. Copyright © 2015 John Wiley & Sons, Ltd.
Bioinformatics Pertinent to Lipid Analysis in Biological Samples.
Ma, Justin; Arbelo, Ulises; Guerra, Yenifer; Aribindi, Katyayini; Bhattacharya, Sanjoy K; Pelaez, Daniel
2017-01-01
Electrospray ionization mass spectrometry has revolutionized the way lipids are studied. In this work, we present a tutorial for analyzing class-specific lipid spectra obtained from a triple quadrupole mass spectrometer. The open-source software MZmine 2.21 is used, coupled with LIPID MAPS databases. Here, we describe the steps for lipid identification, ratiometric quantification, and briefly address the differences to the analyses when using direct infusion versus tandem liquid chromatography-mass spectrometry (LC-MS). We also provide a tutorial and equations for quantification of lipid amounts using synthetic lipid standards and normalization to a protein amount.
[Identification of related substances in nicergoline by HPLC-MS].
Zeng, Xue-fang; Liu, Jie; Song, Min; Hang, Tai-jun
2015-08-01
To study the related substances in nicergoline, electrospray positive ionization high resolution TOF/MS was used for the determination of the accurate mass and elemental composition of the related substances. Triple quadrupoles tandem MS/MS was employed for the determination of the fragmentations of the parent ions. 16 related substances were detected and identified to be eight synthetic by-products and eight degradation products, by using impurity references matching, product mass spectra fragmentations elucidation, and verified further according to synthetic processes and stress testing results. The results obtained are valuable for nicergoline manufacturing process control and quality assurance.
Zheng, Weijia; Park, Jin-A; Abd El-Aty, A M; Kim, Seong-Kwan; Cho, Sang-Hyun; Choi, Jeong-Min; Warda, Mohamad; Wang, Jing; Shim, Jae-Han; Shin, Ho-Chul
2018-04-01
We have developed an analytical method for the determination of lincomycin, tylosin A and tylosin B residues in royal jelly using liquid chromatography-triple quadrupole tandem mass spectrometry analysis. For extraction and purification, we employed 1% trifluoroacetic acid and 0.1 m Na 2 EDTA solutions along with an Oasis HLB cartridge. The target antibiotics were well separated in a Kinetex EVO C 18 reversed-phase analytical column using a combination of 0.1% formate acid in ultrapure water (A) and acetonitrile (B) as the mobile phase. Good linearity was achieved over the tested concentration range (5-50 μg/kg) in matrix-matched standard calibration. The coefficients of determination (R 2 ) were 0.9933, 0.9933 and 0.996, for tylosin A, tylosin B and lincomycin, respectively. Fortified royal jelly spiked with three different concentrations of the tested antibiotics (5, 10 and 20 μg/kg) yielded recoveries in the range 80.94-109.26% with relative standard deviations ≤4%. The proposed method was applied to monitor 11 brand of royal jelly collected from domestic markets and an imported brand from New Zealand; all the samples tested negative for lincomycin, tylosin A and tylosin B residues. In conclusion, 1% trifluoroacetic acid and 0.1 m Na 2 EDTA aqueous solvents combined with solid-phase extraction could effectively complete the sample preparation process for royal jelly before analysis. The developed approach can be applied for a routine analysis of lincomycin, tylosin A and tylosin B residues in royal jelly. Copyright © 2017 John Wiley & Sons, Ltd.
Planas, Carles; Ventura, Francesc; Caixach, Josep; Martín, Jordi; Boleda, M Rosa; Paraira, Miquel
2015-11-01
A simple, selective and sensitive method for the analysis of the strong mutagen 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX) and its brominated analogues (BMXs) in chlorine-treated water has been developed. The method is based on gas chromatography coupled to triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS), previous liquid-liquid extraction (LLE) of a smaller sample volume compared to other methods and on-line derivatization with a silylation reactive. GC-QqQ-MS/MS has been raised as an alternative easier to perform than gas chromatography coupled to high resolution mass spectrometry (GC-HRMS) for the analysis of MX and BMXs, and it allows to achieve low LODs (0.3 ng/L for MX and 0.4-0.9 ng/L for BMXs). This technique had not been previously described for the analysis of MX and BMXs. Quality parameters were calculated and real samples related to 3 drinking water treatment plants (DWTPs), tap water and both untreated and chlorinated groundwater were analyzed. Concentrations of 0.3-6.6 ng/L for MX and 1.0-7.3 ng/L for BMXs were detected. Results were discussed according to five of the main factors affecting MX and BMXs formation in chlorine-treated water (organic precursors, influence of bromide ions, evolution of MX and BMXs in the drinking water distribution system, groundwater chlorination and infiltration of water coming from chlorination processes in groundwater). Copyright © 2015 Elsevier B.V. All rights reserved.
Xu, Xiaomin; He, Huali; Ruan, Yudi; Huang, Baifen; Zhang, Jingshun; Cai, Zengxuan; Ren, Yiping
2013-11-01
A simultaneous determination method for ethyl carbamate (EC) and chloropropanols (3-monochloropropane-1, 2-diol (3-MCPD) and 2-monochloropropane-1, 3-diol (2-MCPD)) in flavorings was developed by gas chromatography-triple quadrupole tandem mass spectrometry (GC-MS/MS). After spiked with internal standard, the sample was extracted by matrix solid-phase dispersion extraction technique with an Extrelut NT column. Hexane was used to wash the fat soluble matrix interferences and then an ethyl acetate-ethyl ether (20: 80, v/v) mixture was added to elute the analytes. The concentrated extract was detected by GC-MS/MS in multiple reaction monitoring (MRM) mode. The limits of detection (LODs) were 2, 5 and 5 microg/kg for EC, 3-MCPD and 2-MCPD, respectively. The linear ranges were 5 - 1 000 microg/kg (r = 0.9997), 10-1000 microg/kg (r = 0.999 1) and 10-1000 microg/kg (r = 0.999 5) for EC, 3-MCPD and 2-MCPD, respectively. In soy sauce, yellow rice wine, salami sauce and flavoring of instant noodle matrices, the recoveries (RSDs, n = 7) in MRM mode at the levels of 20, 100 and 400 microg/kg were 87.7%-104% (4.3%-10.7%), 90.1%-109% (2.6%-10.2%), and 90.9%-103% (3.0%-9.5%), respectively. EC, 3-MCPD and 2-MCPD were found in some real samples of the soy sauce, wine and flavoring of instant noodle. EC or 3-MCPD was found in some of the salami samples. The method is accurate, fast and suitable for the simultaneous determination of EC, 3-MCPD and 2-MCPD in flavorings.
Lu, Baiyi; Ren, Yiping; Huang, Baifen; Liao, Wenqun; Cai, Zengxuan; Tie, Xiaowei
2008-03-01
A novel ultra-performance liquid chromatography electrospray ionization tandem triple quadrupole mass spectrometry method for the simultaneous determination of four water-soluble vitamins, including vitamin B5 (VB5), vitamin B8 (VB8), vitamin B9 (VB9), and vitamin B12 (VB12) in fortified infant foods is developed and validated. A reverse phase UPLC separation system consisting of a Waters ACQUITY UPLC BEH C-18 column (2.1 mm x 100 mm i.d., 1.7 microm) and a binary gradient acetonitrile-water mobile phase is applied for the separation of the four water-soluble vitamins. Formic acid is spiked into the mobile phase to enhance the ionization efficiency. Tandem MS-MS analysis is performed in multi-reaction monitoring mode (MRM). Product-ion traces at m/z 220.1 --> 89.9 for VB5, 245.1 --> 227.1 for VB8, 442.3 --> 295.2 for VB9, and 678.9 --> 147.0 for VB12 are used for quantitation of the corresponding vitamins, and traces at m/z 455.5 --> 308.0 are used for methotrexate (internal standard). Limits of quantitation (LOQs) are 0.016, 0.090, 0.020, and 0.019 microg/L for VB5, VB8, VB9, and VB12, respectively. Intra- and inter-day precisions for the determination of the four vitamins are better than 6.84% and 12.26% in relative standard deviations, and recoveries for the four vitamins are in the range of 86.0~101.5%. The developed approach is applied for the determination of the trace amounts of the vitamins in fortified milk powers and fortified rice powers.
Matysik, Silke; Liebisch, Gerhard
2017-12-01
A limited specificity is inherent to immunoassays for steroid hormone analysis. To improve selectivity mass spectrometric analysis of steroid hormones by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been introduced in the clinical laboratory over the past years usually with low mass resolution triple-quadrupole instruments or more recently by high resolution mass spectrometry (HR-MS). Here we introduce liquid chromatography-high resolution tandem mass spectrometry (LC-MS/HR-MS) to further increase selectivity of steroid hormone quantification. Application of HR-MS demonstrates an enhanced selectivity compared to low mass resolution. Separation of isobaric interferences reduces background noise and avoids overestimation. Samples were prepared by automated liquid-liquid extraction with MTBE. The LC-MS/HR-MS method using a quadrupole-Orbitrap analyzer includes eight steroid hormones i.e. androstenedione, corticosterone, cortisol, cortisone, 11-deoxycortisol, 17-hydroxyprogesterone, progesterone, and testosterone. It has a run-time of 5.3min and was validated according to the U.S. Food and Drug Administration (FDA) and the European Medicines Agency (EMA) guidelines. For most of the analytes coefficient of variation were 10% or lower and LOQs were determined significantly below 1ng/ml. Full product ion spectra including accurate masses substantiate compound identification by matching their masses and ratios with authentic standards. In summary, quantification of steroid hormones by LC-MS/HR-MS is applicable for clinical diagnostics and holds also promise for highly selective quantification of other small molecules. Copyright © 2017 Elsevier B.V. All rights reserved.
Alvim, Joel; Lopes, Bianca Rebelo; Cass, Quezia Bezerra
2016-06-17
A two-dimensional liquid chromatography system coupled to triple quadrupole tandem mass spectrometer (2D LC-MS/MS) was employed for the simultaneously quantification of fluoxetine (FLX) and norfluoxetine (NFLX) enantiomers in human milk by direct injection of samples. A restricted access media of bovine serum albumin octadecyl column (RAM-BSAC18) was used in the first dimension for the milk proteins depletion, while an antibiotic-based chiral column was used in the second dimension. The results herein described show good selectivity, extraction efficiency, accuracy, and precision with limits of quantification in the order of 7.5ngmL(-1)for the FLX enantiomers and 10.0ngmL(-1) for NFLX enantiomers. Furthermore, it represents a practical tool in terms of sustainability for the sample preparation of such a difficult matrix. Copyright © 2016 Elsevier B.V. All rights reserved.
Peters, Frank T
2011-01-01
Liquid chromatography (LC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) has become increasingly important in clinical and forensic toxicology as well as doping control and is now a robust and reliable technique for routine analysis in these fields. In recent years, methods for LC-MS(/MS)-based systematic toxicological analysis using triple quadrupole or ion trap instruments have been considerably improved and a new screening approach based on high-resolution MS analysis using benchtop time-of-flight MS instruments has been developed. Moreover, many applications for so-called multi-target screening and/or quantification of drugs, poisons, and or their metabolites in various biomatrices have been published. The present paper will provide an overview and discuss these recent developments focusing on the literature published after 2006. Copyright © 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Liu, Shao-Ying; Huang, Xi-Hui; Wang, Xiao-Fang; Jin, Quan; Zhu, Guo-Nian
2014-05-01
This study developed an improved analytical method for the simultaneous quantification of 13 quinolones in cosmetics by ultra high performance liquid chromatography combined with ESI triple quadrupole MS/MS under the multiple reaction monitoring mode. The analytes were extracted and purified by using an SPE cartridge. The limits of quantification ranged from 0.03 to 3.02 μg/kg. The precision for determining the quinolones was <19.39%. The proposed method was successfully developed for the determination of quinolones in real cosmetic samples. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Rúbies, Antoni; Guo, Lili; Centrich, Francesc; Granados, Mercè
2016-08-01
We developed a Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) method for the high throughput determination of 10 non-steroidal anti-inflammatory drugs (NSAIDs) in milk samples using high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) with a triple quadrupole (QqQ) instrument and an electrospray ionization (ESI) source. The new extraction procedure is highly efficient, and we obtained absolute recoveries in the range 78.1-97.1 % for the extraction and clean-up steps. Chromatographic separation is performed in the gradient mode with a biphenyl column and acidic mobile phases consisting of water and acetonitrile containing formic acid. The chromatographic run time was about 12 min, and NSAID peaks showed a good symmetry factor. For MS/MS detection, we used multiple reaction monitoring (MRM) mode, using ESI in both positive and negative modes. Our method has been validated in compliance with the European Commission Decision 657/2002/EC, and we obtained very satisfactory results in inter-laboratory testing. Furthermore, we explored the use of a hybrid high resolution mass spectrometer, combining a quadrupole and an Orbitrap mass analyzer, for high resolution (HR) MS/MS detection of NSAIDs. We achieved lower NSAID quantification limits with Q-Orbitrap high resolution mass spectrometry (HRMS/MS) detection than those achieved with the QqQ instrument; however, its main feature is its very high selectivity, which makes HRMS/MS particularly suitable for confirmatory analysis.
Soler, Carla; James, K J; Picó, Yolanda
2007-07-20
Three different liquid chromatography-mass spectrometry (LC-MS) instruments equipped with triple quadrupole (QqQ), quadrupole ion trap (QIT) and quadrupole-time-of-flight (QqTOF), suitable to carry out tandem mass spectrometry, were examined to determine pesticide residues in food. Twelve pesticides (acrinathrin, bupirimate, buprofezin, cyproconazole, lambda-cyhalothrin, fluvalinate, hexaflumuron, kresoxim-methyl, propanil, pyrifenox, pyriproxyfen and tebufenpyrad) and six matrices (oranges, strawberries, cherries, peaches, apricots and pears) were taken as model. The comparison was focused on two aspects: the quantitative, covering sensitivity, precision and accuracy as well as the qualitative, checking the possibility to identify any metabolite present in the samples, which were not targeted in the methods. The extraction was carried out using pressurized liquid extraction (PLE) with ethyl acetate and acid alumina. Recoveries were over 70 % for all the analytes. Repeatabilities were better for the QqQ (5-12%) than for QIT (6-15%) and for QqTOF (14-19%). QqQ offered a linear dynamic range of at least three orders of magnitude, whereas those of QIT and QqTOF were two and one orders of magnitude, respectively. QqQ reached at least 20-fold higher sensitivity than QIT and QqTOF. However, the QqQ failed to identify non-target compounds. QIT and QqTOF were able to successfully identify the metabolite of bupirimate, ethirimol. Application to monitor the content in fruits, taken from agricultural cooperatives, and to calculate the estimated daily intake (EDI) to establish if there is any difference of toxicological interest is also reported.
Chen, Xiaoyan; Huang, Jia; Kong, Zhang; Zhong, Dafang
2005-03-25
A rapid and sensitive method for the simultaneous determination of paracetamol and guaifenesin in human plasma was developed and validated, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. After extracted from plasma samples by diethyl ether-dichloromethane (3:2, v/v), the analytes and internal standard osalmide were chromatographed on a C18 column. Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via atmospheric pressure chemical ionization (APCI). The method was linear in the concentration range of 0.05-20.0 microg/ml for paracetamol and 5.0-2000.0 ng/ml for guaifenesin. The intra- and inter-day precision was within 14% for both paracetamol and guaifenesin. The assay accuracy was within +/-2.4% for the analytes. This is the first assay method described for the simultaneous determination of paracetamol and guaifenesin in plasma using one chromatographic run. The method was successfully employed in a pharmacokinetic study after an oral administration of a multicomponent formulation, containing 650 mg paracetamol, 200 mg guaifenesin, 60 mg pseudoephedrine and 20 mg dextrorphan.
Correlation between y-type ions observed in ion trap and triple quadrupole mass spectrometers.
Sherwood, Carly A; Eastham, Ashley; Lee, Lik Wee; Risler, Jenni; Vitek, Olga; Martin, Daniel B
2009-09-01
Multiple reaction monitoring mass spectrometry (MRM-MS) is a technique for high-sensitivity targeted analysis. In proteomics, MRM-MS can be used to monitor and quantify a peptide based on the production of expected fragment peaks from the selected peptide precursor ion. The choice of which fragment ions to monitor in order to achieve maximum sensitivity in MRM-MS can potentially be guided by existing MS/MS spectra. However, because the majority of discovery experiments are performed on ion trap platforms, there is concern in the field regarding the generalizability of these spectra to MRM-MS on a triple quadrupole instrument. In light of this concern, many operators perform an optimization step to determine the most intense fragments for a target peptide on a triple quadrupole mass spectrometer. We have addressed this issue by targeting, on a triple quadrupole, the top six y-ion peaks from ion trap-derived consensus library spectra for 258 doubly charged peptides from three different sample sets and quantifying the observed elution curves. This analysis revealed a strong correlation between the y-ion peak rank order and relative intensity across platforms. This suggests that y-type ions obtained from ion trap-based library spectra are well-suited for generating MRM-MS assays for triple quadrupoles and that optimization is not required for each target peptide.
Xia, Yong-Gang; Guo, Xin-Dong; Liang, Jun; Yang, Bing-You; Kuang, Hai-Xue
2017-09-01
This study presents a practical and valid strategy for the screening and structural characterization of Anemarrhena asphodeloides Bge steroidal saponins (SSs) using ultra-high performance liquid chromatography coupled with triple quadrupole linear ion trap mass spectrometry. The whole analytical protocols integrate four-step procedures in the positive mode: (1) rational deduction of mass fragmentation pathways of A. asphodeloides SSs; (2) untargeted screening of potential A. asphodeloides SSs by multiple-ion monitoring-information-dependent-acquiring-enhanced product ion (MIM-IDA-EPI) scan through reverse phase liquid chromatography; (3) comprehensive construction of an ammoniated precursor ion database by combining untargeted MIM-IDA-EPI scans and data literature; and (4) structural interpretation of targeted A. asphodeloides SSs using MIM-IDA-EPI and multiple reaction monitoring (MRM)-IDA-EPI with an energy-resolved technique. The protocols were used to analyze SSs in A. asphodeloides; of the 87 detected SSs that were unambiguously characterized or tentatively identified, 19 compounds were the first to be reported from A. asphodeloides and 13 ones were characterized as potential new compounds. Accuracy of the analytical procedure was demonstrated by structural identification of three SSs by NMR spectroscopy. The proposed schemes hold an excellent promise in the structural prediction and interpretation of complex SSs from plant medicines by mass spectrometry. Copyright © 2017 Elsevier Inc. All rights reserved.
García-Altares, María; Casanova, Alexis; Bane, Vaishali; Diogène, Jorge; Furey, Ambrose; de la Iglesia, Pablo
2014-01-01
Cyclic imines are lipophilic marine toxins that bioaccumulate in seafood. Their structure comprises a cyclic-imino moiety, responsible for acute neurotoxicity in mice. Cyclic imines have not been linked yet to human poisonings and are not regulated in Europe, although the European Food Safety Authority requires more data to perform a conclusive risk assessment for consumers. This work presents the first detection of pinnatoxin G (PnTX-G) in Spain and 13-desmethyl spirolide C (SPX-1) in shellfish from Catalonia (Spain, NW Mediterranean Sea). Cyclic imines were found at low concentrations (2 to 60 µg/kg) in 13 samples of mussels and oysters (22 samples analyzed). Pinnatoxin G has been also detected in 17 seawater samples (out of 34) using solid phase adsorption toxin tracking devices (0.3 to 0.9 µg/kg-resin). Pinnatoxin G and SPX-1 were confirmed with both low and high resolution (<2 ppm) mass spectrometry by comparison of the response with that from reference standards. For other analogs without reference standards, we applied a strategy combining low resolution MS with a triple quadrupole mass analyzer for a fast and reliable screening, and high resolution MS LTQ Orbitrap® for unambiguous confirmation. The advantages and limitations of using high resolution MS without reference standards were discussed. PMID:24960460
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belov, Mikhail E.; Prasad, Satendra; Prior, David C.
2011-02-23
Liquid chromatography (LC)-triple quadrupole mass spectrometers operating in a Multiple Reaction Monitoring (MRM) mode are increasingly used for quantitative analysis of low abundance analytes in highly complex biochemical matrices. After development and selection of optimum MRM transition, sensitivity and data quality limitations are largely related to mass spectral peak interferences from sample or matrix constituents and statistical limitations at low number of ions reaching the detector. Herein, we report a new approach to enhancing MRM sensitivity by converting the continuous stream of ions from the ion source into a pulsed ion beam through the use of an Ion Funnel Trapmore » (IFT). Evaluation of the pulsed MRM approach was performed with a tryptic digest of Shewanella oneidensis strain MR-1 spiked with several reference peptides. The sensitivity improvement observed with the IFT coupled to the triple quadrupole instrument is based on several unique features. First, ion accumulation in the radio frequency (RF) ion trap facilitates improved droplet desolvation, which is manifested in the reduced background ion noise at the detector. Second, signal amplitude for a given transition is enhanced because of an order-of-magnitude increase in the ion charge density per unit time compared to a continuous mode of operation. Third, signal detection at the full duty cycle is obtained, as the trap use eliminates dead times between transitions, which are inevitable with continuous ion streams. In comparison with the conventional approach, the pulsed MRM signals showed up to 5-fold enhanced peak amplitude and 2-3 fold reduced chemical background, resulting in an improvement in the limit of detection (LOD) by a factor of ~ 4 to ~ 8.« less
Zhou, Xiaotong; Meng, Xiangjun; Cheng, Longmei; Su, Chong; Sun, Yantong; Sun, Lingxia; Tang, Zhaohui; Fawcett, John Paul; Yang, Yan; Gu, Jingkai
2017-05-16
Polyethylene glycols (PEGs) are synthetic polymers composed of repeating ethylene oxide subunits. They display excellent biocompatibility and are widely used as pharmaceutical excipients. To fully understand the biological fate of PEGs requires accurate and sensitive analytical methods for their quantitation. Application of conventional liquid chromatography-tandem mass spectrometry (LC-MS/MS) is difficult because PEGs have polydisperse molecular weights (MWs) and tend to produce multicharged ions in-source resulting in innumerable precursor ions. As a result, multiple reaction monitoring (MRM) fails to scan all ion pairs so that information on the fate of unselected ions is missed. This Article addresses this problem by application of liquid chromatography-triple-quadrupole/time-of-flight mass spectrometry (LC-Q-TOF MS) based on the MS ALL technique. This technique performs information-independent acquisition by allowing all PEG precursor ions to enter the collision cell (Q2). In-quadrupole collision-induced dissociation (CID) in Q2 then effectively generates several fragments from all PEGs due to the high collision energy (CE). A particular PEG product ion (m/z 133.08592) was found to be common to all linear PEGs and allowed their total quantitation in rat plasma with high sensitivity, excellent linearity and reproducibility. Assay validation showed the method was linear for all linear PEGs over the concentration range 0.05-5.0 μg/mL. The assay was successfully applied to the pharmacokinetic study in rat involving intravenous administration of linear PEG 600, PEG 4000, and PEG 20000. It is anticipated the method will have wide ranging applications and stimulate the development of assays for other pharmaceutical polymers in the future.
Donaldson, Keri J; Shaw, Leslie M
2010-01-01
We describe a multiple reaction monitoring positive ion HPLC/tandem mass spectrometric method for quantification of tacrolimus in human whole blood with online extraction and cleanup. Included in this procedure: API 2000 triple quadrupole mass spectrometer with turbo-ion spray source (Applied Biosystems, Foster City, CA); 10-port diverter/switching valve (Valco, Houston, TX); HPLC system (Agilent Technologies series 1100, Wilmington, DE); 10 mm (C(18)) guard cartridge (Perkin Elmer, Norwalk, CT) used as an extraction column; a Nova-Pak C18 analytical column (2.1 x 150 mm I.D., 4 microm, Waters Corp, Milford, MA); washing solution, methanol: 30 mM ammonium acetate pH 5.1 (80:20); eluting solution, methanol:30 mM ammonium acetate pH 5.1 (97:3); flow rate 0.8 mL/min; and a run-time of 2.8 min. The first and third quadrupoles were set to detect the ammonium adduct ion and a high mass fragment of tacrolimus (m/z 821.5-->768.3), and of an internal standard (ascomycin) (m/z 901.8-->834.4). The lower limit of quantification of this method is 3.75 mg/L. The concentration of drug is determined by comparing peak-area ratios for tacrolimus and internal standard to a standard curve constructed using non-weighted linear through zero regression.
Lopes, Bianca Rebelo; Cassiano, Neila Maria; Carvalho, Daniela Miarelli; Moisés, Elaine Christine Dantas; Cass, Quezia Bezerra
2018-02-20
A two-dimensional liquid chromatography system coupled to triple quadrupole tandem mass spectrometer (2D LC-MS/MS) was employed for the determination of fluoxetine (FLU) and norfluoxetine (N-FLU) in colostrum and mature milk by direct sample injection. With a run time of 12 min representing a gain in throughput analysis, the validated methods furnished selectivity, extraction efficiency, accuracy, and precision in accordance with the criteria preconized by the European Medicines Agency guidelines. With a linear range of 3.00-150 ng/mL for FLU and 4.00-200 ng/mL for N-FLU they were applied to the analysis of colostrum and mature milk samples from nursing mothers. The paper discusses the differences and similarity of sample preparation for this two sample matrices. The herein reported methods are an advance in sample preparation procedures providing waste reduction and a sustainable approach. Copyright © 2017 Elsevier B.V. All rights reserved.
Gergov, M; Ojanperä, I; Vuori, E
2003-09-25
A liquid chromatography-tandem mass spectrometry (LC-MS-MS) method is presented for the qualitative screening for 238 drugs in blood samples, which is considerably more than in previous methods. After a two-step liquid-liquid extraction and C(18) chromatography, the compounds were introduced into a triple quadrupole mass spectrometer equipped with a turbo ion spray ion source operating in the positive ionization mode. Identification was based on the compound's absolute retention time, protonated molecular ion, and one representative fragment ion obtained by multiple reaction monitoring (MRM) at an individually selected collision energy of 20, 35, or 50 eV. The limit of detection (LOD) for the majority of the compounds (80%) was < or = 0.05 mg/l, ranging from 0.002 mg/l (e.g., antihistamines) to 5 mg/l (acidic compounds), and for malathion it was 10 mg/l. The LOD values were sufficiently low to allow the majority of compounds to be detected at therapeutic concentrations in the blood.
Wang, Jiang; Jiang, Yao; Wang, Yingwu; Zhao, Xia; Cui, Yimin; Gu, Jingkai
2007-05-09
A simple, sensitive and specific liquid chromatography/tandem mass spectrometry method for the quantitation of aildenafil, a new phosphodiesterase V inhibitor, in human plasma is presented. The analyte and internal standard, sildenafil, were extracted by a one-step liquid-liquid extraction in alkaline conditions and separated on a C(18) column using ammonia:10mM ammonium acetate buffer:methanol (0.1:15:85, v/v/v) as the mobile phase. The detection by an API 4000 triple quadrupole mass spectrometer in multiple-reaction monitoring mode was completed within 2.5 min. The calibration curve exhibited a linear dynamic range of 0.05-100 ng/ml with a 10 pg/ml limit of detection. The intra- and inter-day precisions measured as relative standard deviation were within 8.04% and 5.72%, respectively. This method has been used in a pharmacokinetic study of aildenafil in healthy male volunteers each given an oral administration of one of the three dosages.
Wu, Guo-Lan; Zhou, Hui-Li; Shentu, Jian-Zhong; He, Qiao-Jun; Yang, Bo
2008-12-15
A simple, sensitive and rapid LC/MS/MS method was developed for the quantification of lansoprazole in human plasma. After a simple sample preparation procedure by one-step protein precipitation with acetonitrile, lansoprazole and the internal standard bicalutamide were chromatographed on a Zorbax SB-C(18) (3.0 mm x 150 mm, 3.5 microm, Agilent) column with the mobile phase consisted of methanol-water (70:30, v/v, containing 5 mM ammonium formate, pH was adjusted to 7.85 by 1% ammonia solution). Detection was performed on a triple quadrupole tandem mass spectrometry by multiple reaction monitoring (MRM) mode via negative eletrospray ionization source (ESI(-)). The lower limit of quantification was 5.5 ng/mL, and the assay exhibited a linear range of 5.5-2200.0 ng/mL. The validated method was successfully applied to investigate the bioequivalence between two kinds of preparation (test vs. reference product) in twenty-eight healthy male Chinese volunteers.
Li, Li; Xing, Dong-Xu; Li, Qing-Rong; Xiao, Yang; Ye, Ming-Qiang; Yang, Qiong
2014-01-01
Albendazole is a broad-spectrum parasiticide with high effectiveness and low host toxicity. No method is currently available for measuring albendazole and its metabolites in silkworm hemolymph. This study describes a rapid, selective, sensitive, synchronous and reliable detection method for albendazole and its metabolites in silkworm hemolymph using ultrafast liquid chromatography tandem triple quadrupole mass spectrometry (UFLC-MS/MS). The method is liquid-liquid extraction followed by UFLC separation and quantification in an MS/MS system with positive electrospray ionization in multiple reaction monitoring mode. Precursor-to-product ion transitions were monitored at 266.100 to 234.100 for albendazole (ABZ), 282.200 to 208.100 for albendazole sulfoxide (ABZSO), 298.200 to 159.100 for albendazole sulfone (ABZSO2) and 240.200 to 133.100 for albendazole amino sulfone (ABZSO2-NH2). Calibration curves had good linearities with R2 of 0.9905–0.9972. Limits of quantitation (LOQs) were 1.32 ng/mL for ABZ, 16.67 ng/mL for ABZSO, 0.76 ng/mL for ABZSO2 and 5.94 ng/mL for ABZSO2-NH2. Recoveries were 93.12%–103.83% for ABZ, 66.51%–108.51% for ABZSO, 96.85%–105.6% for ABZSO2 and 96.46%–106.14% for ABZSO2-NH2, (RSDs <8%). Accuracy, precision and stability tests showed acceptable variation in quality control (QC) samples. This analytical method successfully determined albendazole and its metabolites in silkworm hemolymph in a pharmacokinetic study. The results of single-dose treatment suggested that the concentrations of ABZ, ABZSO and ABZSO2 increased and then fell, while ABZSO2-NH2 level was low without obvious change. Different trends were observed for multi-dose treatment, with concentrations of ABZSO and ABZSO2 rising over time. PMID:25255321
Li, Li; Xing, Dong-Xu; Li, Qing-Rong; Xiao, Yang; Ye, Ming-Qiang; Yang, Qiong
2014-01-01
Albendazole is a broad-spectrum parasiticide with high effectiveness and low host toxicity. No method is currently available for measuring albendazole and its metabolites in silkworm hemolymph. This study describes a rapid, selective, sensitive, synchronous and reliable detection method for albendazole and its metabolites in silkworm hemolymph using ultrafast liquid chromatography tandem triple quadrupole mass spectrometry (UFLC-MS/MS). The method is liquid-liquid extraction followed by UFLC separation and quantification in an MS/MS system with positive electrospray ionization in multiple reaction monitoring mode. Precursor-to-product ion transitions were monitored at 266.100 to 234.100 for albendazole (ABZ), 282.200 to 208.100 for albendazole sulfoxide (ABZSO), 298.200 to 159.100 for albendazole sulfone (ABZSO2) and 240.200 to 133.100 for albendazole amino sulfone (ABZSO2-NH2). Calibration curves had good linearities with R2 of 0.9905-0.9972. Limits of quantitation (LOQs) were 1.32 ng/mL for ABZ, 16.67 ng/mL for ABZSO, 0.76 ng/mL for ABZSO2 and 5.94 ng/mL for ABZSO2-NH2. Recoveries were 93.12%-103.83% for ABZ, 66.51%-108.51% for ABZSO, 96.85%-105.6% for ABZSO2 and 96.46%-106.14% for ABZSO2-NH2, (RSDs <8%). Accuracy, precision and stability tests showed acceptable variation in quality control (QC) samples. This analytical method successfully determined albendazole and its metabolites in silkworm hemolymph in a pharmacokinetic study. The results of single-dose treatment suggested that the concentrations of ABZ, ABZSO and ABZSO2 increased and then fell, while ABZSO2-NH2 level was low without obvious change. Different trends were observed for multi-dose treatment, with concentrations of ABZSO and ABZSO2 rising over time.
Vento, V Thatar; Bergueiro, J; Cartelli, D; Valda, A A; Kreiner, A J
2011-12-01
Within the frame of an ongoing project to develop a folded Tandem-Electrostatic-Quadrupole (TESQ) accelerator facility for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT), we discuss here the electrostatic design of the machine, including the accelerator tubes with electrostatic quadrupoles and the simulations for the transport and acceleration of a high intensity beam. Copyright © 2011 Elsevier Ltd. All rights reserved.
Lijia, Xu; Guo, Jianru; Chen, QianQian; Baoping, Jiang; Zhang, Wei
2014-06-01
A sensitive and selective ultra high performance liquid chromatography-tandem mass spectrometric (UHPLC-MS/MS) method for the determination of phlorizin and phloretin in human plasma has been firstly developed. Samples were prepared after protein precipitation and analyzed on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. Negative electrospray ionization was employed as the ionization source. The mobile phase consisted of acetonitrile-water (0.02% formic acid), using a gradient procedure. The analytes and internal standard dihydroquercetin were both detected by use of multiple reaction monitoring mode. The method was linear in the concentration range of 2.5-1000.0 ng/mL. The lower limit of quantification (LLOQ) was 2.5 ng/mL. The intra- and inter-day relative standard deviation across three validation runs over the entire concentration range was less than 9.2%. The accuracy determined at three concentrations was within ± 7.3% in terms of relative error. The total run time was 12.0 min. This assay offers advantages in terms of expediency, and suitability for the analysis of phlorizin and phloretin in various biological fluids. Copyright © 2014 Elsevier B.V. All rights reserved.
Li, Ting Yu; Huo, Xiao Kui; Zheng, Lu; Wang, Chao; Cong, Hai Jian; Xiang, Ting; Zhang, Lin; Zhang, Bao Jing; Huang, Shan Shan; Wu, Bin; Li, Xin Yu
2017-01-01
Background: Chaiqin Qingning Capsule (CQQNC) was a prescription of Traditional Chinese Medicine with the effects of clearing away heat and removing toxin, harmonizing the exterior and interior, it was widely used in Asian, for example, China and Japan, different batches of the raws materials and different processing time may be the vital factor which raised a challenge to control the quality of the CQQNC. Experimental Methods: In this experiment, a high-performance liquid chromatography-mass spectrometry/MS (HPLC-MS/MS) method was developed to simultaneously determine ten bioactive components for the quality control of CQQNC. Chromatographic separation was achieved using an XBridge BEH C18 column (150 mm × 4.6 mm, 2.5 μm) with a mobile phase composed of 10 mm aqueous ammonium acetate and acetonitrile using a gradient elution in 20 min. This study was conducted by multiple reaction monitoring mode through electrospray ionization resource with a negative ionization mode. Results: The established method was validated with good performance of precision, accuracy, stability, and reproducibility and was utilized to simultaneously quantify ten constituents of CQQNC obtained from seven different batches. Conclusion: It is the first time to report the rapid and simultaneous analysis of the ten compounds in CQQNC by HPLC-MS/MS and apply to determine 10 constituents in 7 batches of CQQNC bought from drug store in china. This method could be considered as good quality criteria to control the quality of CQQNC. SUMMARY In this paper, a simple, specific, and rapid high-performance liquid chromatogram coupled with triple-quadrupole mass spectrometry method for simultaneous quantification of ten constituents in Chaiqin Qingning Capsule has been developed for the first time. This method could be considered as good quality criteria to control the quality of CQQNC. Abbreviations used: CHM: Chinese herbal medicine; TCM: Traditional Chinese Medicine; CQQNC: Triple-quadrupole mass spectrometry Chaiqin Qingning Capsules; HPLC–MS/MS: High liquid chromatography equipped with tandem mass spectrometry; ESI: Electrospray ionization; DP: Declustering potential; CE: Collision energy; RSD: Relative standard deviation; LOD: Limit of detection; LOQ: Limit of quantity. PMID:29200714
Li, Ting Yu; Huo, Xiao Kui; Zheng, Lu; Wang, Chao; Cong, Hai Jian; Xiang, Ting; Zhang, Lin; Zhang, Bao Jing; Huang, Shan Shan; Wu, Bin; Li, Xin Yu
2017-01-01
Chaiqin Qingning Capsule (CQQNC) was a prescription of Traditional Chinese Medicine with the effects of clearing away heat and removing toxin, harmonizing the exterior and interior, it was widely used in Asian, for example, China and Japan, different batches of the raws materials and different processing time may be the vital factor which raised a challenge to control the quality of the CQQNC. In this experiment, a high-performance liquid chromatography-mass spectrometry/MS (HPLC-MS/MS) method was developed to simultaneously determine ten bioactive components for the quality control of CQQNC. Chromatographic separation was achieved using an XBridge BEH C18 column (150 mm × 4.6 mm, 2.5 μm) with a mobile phase composed of 10 mm aqueous ammonium acetate and acetonitrile using a gradient elution in 20 min. This study was conducted by multiple reaction monitoring mode through electrospray ionization resource with a negative ionization mode. The established method was validated with good performance of precision, accuracy, stability, and reproducibility and was utilized to simultaneously quantify ten constituents of CQQNC obtained from seven different batches. It is the first time to report the rapid and simultaneous analysis of the ten compounds in CQQNC by HPLC-MS/MS and apply to determine 10 constituents in 7 batches of CQQNC bought from drug store in china. This method could be considered as good quality criteria to control the quality of CQQNC. In this paper, a simple, specific, and rapid high-performance liquid chromatogram coupled with triple-quadrupole mass spectrometry method for simultaneous quantification of ten constituents in Chaiqin Qingning Capsule has been developed for the first time. This method could be considered as good quality criteria to control the quality of CQQNC. Abbreviations used: CHM: Chinese herbal medicine; TCM: Traditional Chinese Medicine; CQQNC: Triple-quadrupole mass spectrometry Chaiqin Qingning Capsules; HPLC-MS/MS: High liquid chromatography equipped with tandem mass spectrometry; ESI: Electrospray ionization; DP: Declustering potential; CE: Collision energy; RSD: Relative standard deviation; LOD: Limit of detection; LOQ: Limit of quantity.
Hori, Katsuhito; Tsumura, Kazunobu; Fukusaki, Eiichiro; Bamba, Takeshi
2014-01-01
Supercritical fluid chromatography (SFC) coupled with triple quadrupole mass spectrometry was applied to the profiling of sucrose fatty acid esters (SEs). The SFC conditions (column and modifier gradient) were optimized for the effective separation of SEs. In the column test, a silica gel reversed-phase column was selected. Then, the method was used for the detailed characterization of commercial SEs and the successful analysis of SEs containing different fatty acids. The present method allowed for fast and high-resolution separation of monoesters to tetra-esters within a shorter time (15 min) as compared to the conventional high-performance liquid chromatography. The applicability of our method for the analysis of SEs was thus demonstrated. PMID:26819875
Weidolf, L O; Lee, E D; Henion, J D
1988-03-01
Sulfoconjugated anabolic steroids were separated by micro-bore high-performance liquid chromatography. The eluent was introduced into the atmospheric pressure ion source of the triple-quadrupole mass spectrometer via an ion spray liquid chromatograph/mass spectrometer interface operated in the negative ion mode. The limit of detection was 10 pg on-column by selected ion monitoring of the molecular ion and the response increased linearly over a concentration range of 2.4 orders of magnitude. Following work-up by a liquid-solid extraction procedure of equine urine samples, full-scan daughter ion spectra of boldenone sulfate could be obtained up to 17 days after a therapeutic dose of boldenone undecylenate to a horse.
Enantioselective behaviour of tetraconazole during strawberry wine-making process.
Liu, Na; Pan, Xinglu; Zhang, Shuang; Ji, Mingshan; Zhang, Zhihong
2018-05-01
The fate of tetraconazole enantiomers in strawberries during wine-making process was studied. The residues were determined by ultra-performance convergence chromatography tandem triple quadrupole mass spectrometry after each process steps. Results indicated that there was significant enantioselective dissipation of tetraconazole enantiomers during the fermentation process. And (-)-tetraconazole degraded faster than (+)-tetraconazole. The half-lives of (-)-tetraconazole and (+)-tetraconazole were 3.12, 3.76 days with washing procedure and 3.18, 4.05 days without washing procedure. The processing factors of strawberry wine samples after each step were generally less than 1. In particular, the processing factors of the fermentation process were the lowest. The results could help facilitate more accurate risk assessments of tetraconazole during wine-making process. © 2018 Wiley Periodicals, Inc.
Shen, Qing; Dai, Zhiyuan; Lu, Yanbin
2010-10-01
An ultra-fast high-performance LC-ESI-MS/MS method was developed for the analysis and quantification of caffeoylquinic acid derivatives, including chlorogenic acid, 1,3-di-O-caffeoylquinic acid (cynarin) and 1,5-di-O-caffeoylquinic acid, in artichoke (Cynara scolymus L.) heads and leaves. The rapid separation (less than 4 min) was achieved based on a Halo fused core C18-silica column (50 mm × 2.1 mm id, 2.7 μm). The target compounds were detected and quantified by a triple-quadrupole mass spectrometer in multiple-reaction monitoring mode. The calibration function is linear from 0.06 to 2800 ng/mL for chlorogenic acid, 0.3-3000 ng/mL for cynarin and 0.24-4800 ng/mL for 1,5-di-O-caffeoylquinic acid, respectively. The average recoveries ranged from 92.1 to 113.2% with RSDs ≤6.5%. Moreover, four batches of artichoke head and leaf extracts were analyzed using the established method. The results indicated that the Halo fused core column provided much faster separations and higher sample throughput without sacrificing column ruggedness and reliability, and triple-quadrupole MS provided extraordinarily lower LOQs for most of the target analytes. Comparing to conventional quantitative approaches, the established method was fast, sensitive and reliable for the determination of caffeoylquinic acid derivatives in artichoke.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wunschel, David S.; Valenzuela, Blandina R.; Kaiser, Brooke L. Deatherage
A variety of toxins are produced by marine and freshwater microorganisms that present a threat to human health. These toxins have diverse chemical properties and specifically, a range of hydrophobicity. Methods for extraction and identification of these toxins are often geared toward specific classes of toxin depending on the sample type. There is a need for a general method of toxin extraction and identification for screening samples where the likely toxin content is not known a priori. Here, we have applied a general method for metabolite extraction to toxin containing samples. This method was coupled with a simple dual liquidmore » chromatography approach for separating a broad range of toxins. This liquid chromatography approach was coupled to triple quadrupole and quadrupole time-of-flight MS/MS platforms. The method was testing on a fish matrix for recovery of palytoxin as well as marine corals for detection of natural mixtures of palytoxin analogues. The recovery of palytoxin was found to produce a linear response (R 2 of 0.95) when spiked into the fish matrix with a limit of quantitation of 2.5 ng/μL and recovery efficiency of 73% +/- 9%. The screening of corals revealed varying amount of palytoxin, and in one case, different palytoxin structural analogues. This demonstration illustrates the potential utility of this method for toxin extraction and detection.« less
Wunschel, David S.; Valenzuela, Blandina R.; Kaiser, Brooke L. Deatherage; ...
2018-05-09
A variety of toxins are produced by marine and freshwater microorganisms that present a threat to human health. These toxins have diverse chemical properties and specifically, a range of hydrophobicity. Methods for extraction and identification of these toxins are often geared toward specific classes of toxin depending on the sample type. There is a need for a general method of toxin extraction and identification for screening samples where the likely toxin content is not known a priori. Here, we have applied a general method for metabolite extraction to toxin containing samples. This method was coupled with a simple dual liquidmore » chromatography approach for separating a broad range of toxins. This liquid chromatography approach was coupled to triple quadrupole and quadrupole time-of-flight MS/MS platforms. The method was testing on a fish matrix for recovery of palytoxin as well as marine corals for detection of natural mixtures of palytoxin analogues. The recovery of palytoxin was found to produce a linear response (R 2 of 0.95) when spiked into the fish matrix with a limit of quantitation of 2.5 ng/μL and recovery efficiency of 73% +/- 9%. The screening of corals revealed varying amount of palytoxin, and in one case, different palytoxin structural analogues. This demonstration illustrates the potential utility of this method for toxin extraction and detection.« less
Zhao, Xiangsheng; Wei, Jianhe; Yang, Meihua
2018-05-03
Morinda officinalis is an important herbal medicine and functional food, and its main constituents include anthraquinone and iridoid glycosides. Quantification of the main compounds is a necessary step to understand the quality and therapeutic properties of M. officinalis , but this has not yet been performed based on liquid chromatography/tandem mass spectrometry (LC-MS/MS). Analytes were extracted from M. officinalis by reflux method. Ultrahigh-performance liquid chromatography coupled with a triple quadrupole mass spectrometry (UPLC-QqQ-MS) using multiple reaction monitoring (MRM) mode was applied for quantification. Fragmentation pathways of deacetyl asperulosidic acid and rubiadin were investigated based on UPLC with quadrupole time-of-flight tandem mass spectrometry (Q/TOF-MS) in the MS E centroid mode. The method showed a good linearity over a wide concentration range (R² ≥ 0.9930). The limits of quantification of six compounds ranged from 2.6 to 27.57 ng/mL. The intra- and inter-day precisions of the investigated components exhibited an RSD within 4.5% with mean recovery rates of 95.32⁻99.86%. Contents of selected compounds in M. officinalis varied significantly depending on region. The fragmentation pathway of deacetyl asperulosidic and rubiadin was proposed. A selective and sensitive method was developed for determining six target compounds in M. officinalis by UPLC-MS/MS. Furthermore, the proposed method will be helpful for quality control and identification main compounds of M. officinalis .
Oberacher, Herbert; Pavlic, Marion; Libiseller, Kathrin; Schubert, Birthe; Sulyok, Michael; Schuhmacher, Rainer; Csaszar, Edina; Köfeler, Harald C
2009-04-01
A sophisticated matching algorithm developed for highly efficient identity search within tandem mass spectral libraries is presented. For the optimization of the search procedure a collection of 410 tandem mass spectra corresponding to 22 compounds was used. The spectra were acquired in three different laboratories on four different instruments. The following types of tandem mass spectrometric instruments were used: quadrupole-quadrupole-time-of-flight (QqTOF), quadrupole-quadrupole-linear ion trap (QqLIT), quadrupole-quadrupole-quadrupole (QqQ), and linear ion trap-Fourier transform ion cyclotron resonance mass spectrometer (LIT-FTICR). The obtained spectra were matched to an established MS/MS-spectral library that contained 3759 MS/MS-spectra corresponding to 402 different reference compounds. All 22 test compounds were part of the library. A dynamic intensity cut-off, the search for neutral losses, and optimization of the formula used to calculate the match probability were shown to significantly enhance the performance of the presented library search approach. With the aid of these features the average number of correct assignments was increased to 98%. For statistical evaluation of the match reliability the set of fragment ion spectra was extended with 300 spectra corresponding to 100 compounds not included in the reference library. Performance was checked with the aid of receiver operating characteristic (ROC) curves. Using the magnitude of the match probability as well as the precursor ion mass as benchmarks to rate the obtained top hit, overall correct classification of a compound being included or not included in the mass spectrometric library, was obtained in more than 95% of cases clearly indicating a high predictive accuracy of the established matching procedure. Copyright (c) 2009 John Wiley & Sons, Ltd.
Anumol, Tarun; Lehotay, Steven J; Stevens, Joan; Zweigenbaum, Jerry
2017-04-01
Veterinary drug residues in animal-derived foods must be monitored to ensure food safety, verify proper veterinary practices, enforce legal limits in domestic and imported foods, and for other purposes. A common goal in drug residue analysis in foods is to achieve acceptable monitoring results for as many analytes as possible, with higher priority given to the drugs of most concern, in an efficient and robust manner. The U.S. Department of Agriculture has implemented a multiclass, multi-residue method based on sample preparation using dispersive solid phase extraction (d-SPE) for cleanup and ultrahigh-performance liquid chromatography-tandem quadrupole mass spectrometry (UHPLC-QQQ) for analysis of >120 drugs at regulatory levels of concern in animal tissues. Recently, a new cleanup product called "enhanced matrix removal for lipids" (EMR-L) was commercially introduced that used a unique chemical mechanism to remove lipids from extracts. Furthermore, high-resolution quadrupole-time-of-flight (Q/TOF) for (U)HPLC detection often yields higher selectivity than targeted QQQ analyzers while allowing retroactive processing of samples for other contaminants. In this study, the use of both d-SPE and EMR-L sample preparation and UHPLC-QQQ and UHPLC-Q/TOF analysis methods for shared spiked samples of bovine muscle, kidney, and liver was compared. The results showed that the EMR-L method provided cleaner extracts overall and improved results for several anthelmintics and tranquilizers compared to the d-SPE method, but the EMR-L method gave lower recoveries for certain β-lactam antibiotics. QQQ vs. Q/TOF detection showed similar mixed performance advantages depending on analytes and matrix interferences, with an advantage to Q/TOF for greater possible analytical scope and non-targeted data collection. Either combination of approaches may be used to meet monitoring purposes, with an edge in efficiency to d-SPE, but greater instrument robustness and less matrix effects when analyzing EMR-L extracts. Graphical abstract Comparison of cleanup methods in the analysis of veterinary drug residues in bovine tissues.
Montoro, Paola; Maldini, Mariateresa; Piacente, Sonia; Macchia, Mario; Pizza, Cosimo
2010-01-20
The major phytochemical constituents, namely, alkaloids, flavonoids and ellagic acid derivatives, of leaves of Camptotheca acuminata were identified using high performance liquid chromatography (HPLC) coupled with electrospray mass spectrometry (ESI-MS) in extracts of plants cultivated in Italy and collected at different growth stages. Alkaloids related to camptothecin were identified and quantified by HPLC coupled with ESI-tandem mass spectrometry (MS/MS) employing, respectively, an ion trap and a triple quadrupole mass analyser. The fragmentation patterns of alkaloids related to camptothecin were analysed and a specific Multiple Reaction Monitoring HPLC-MS/MS method was developed for the quantitative determination of these constituents. The described method provides high sensitivity and specificity for the characterisation and quantitative determination of the alkaloids in C. acuminata.
Zhao, Chengliang; Zhang, Nan; He, Weiyan; Li, Rui; Shi, Dan; Pang, Li; Dong, Ning; Xu, Hong; Ji, Honglei
2014-04-01
A sensitive and selective liquid chromatography tandem mass spectrometry was developed and validated for the simultaneous determination of three major lignans (podophyllotoxin, epipodophyllotoxin, and 4'-demethylpodophyllotoxin) in rat plasma using diphenhydramine as the internal standard. The analytes were detected using a triple quadrupole mass spectrometer that was equipped with an electrospray ionization source in the positive ion and selected reaction monitoring modes. The linearity of the calibration curve was good, with coefficients of determination (r(2) ) >0.9914 for all of the analytes. The developed method was successfully applied for the simultaneous determination of the three lignans in rat plasma following oral administration of Diphylleia sinensis extract to rats. Copyright © 2013 John Wiley & Sons, Ltd.
Alarcón-Flores, M Isabel; Hernández-Sánchez, Francisco; Romero-González, Roberto; Plaza-Bolaños, Patricia; Martínez Vidal, J Luis; Garrido Frenich, Antonia
2014-11-01
Phytochemicals content, including several families such as phenolic acids, isoflavones, flavones, flavonols, isothiocyanates, and glucosinolates, was determined in pre-cooked convenience vegetables by ultra high performance liquid chromatography coupled to triple quadrupole tandem mass spectrometry (UHPLC-QqQ-MS/MS). It was observed that there is not a common behavior of the individual concentration of phytochemicals during the lifetime and cooking of the matrix, and compounds change their concentration without a specific trend. It was observed that neither lifetime nor cooking process have significant effects on the total content of phytochemicals except in broccoli, although some changes in the individual content of the target compounds were observed, suggesting that interconversion processes could be performed during the lifetime and/or cooking process of the product.
Mari, Angela; Montoro, Paola; Pizza, Cosimo; Piacente, Sonia
2012-11-01
A validated analytical method for the quantitative determination of seven chemical markers occurring in a hydroalcoholic extract of Vitex agnus-castus fruits by liquid chromatography electrospray triple quadrupole tandem mass spectrometry (LC/ESI/(QqQ)MSMS) is reported. To carry out a comparative study, five commercial food supplements corresponding to hydroalcoholic extracts of V. agnus-castus fruits were analysed under the same chromatographic conditions of the crude extract. Principal component analysis (PCA), based only on the variation of the amount of the seven chemical markers, was applied in order to find similarities between the hydroalcoholic extract and the food supplements. A second PCA analysis was carried out considering the whole spectroscopic data deriving from liquid chromatography electrospray linear ion trap mass spectrometry (LC/ESI/(LIT)MS) analysis. High similarity between the two PCA was observed, showing the possibility to select one of these two approaches for future applications in the field of comparative analysis of food supplements and quality control procedures. Copyright © 2012 Elsevier B.V. All rights reserved.
Munaretto, Juliana S; Ferronato, Giovana; Ribeiro, Lucila C; Martins, Manoel L; Adaime, Martha B; Zanella, Renato
2013-11-15
Endocrine Disrupter Compounds (EDCs) are responsible for alterations in the endocrine system functions. Aquatic organisms are able to accumulate EDCs residues, being the major source of contamination for top predators and human consumers. This study aimed to develop and validate a method for the determination of 40 EDCs in fish fillet using modified QuEChERS and Gas Chromatography coupled with Mass Spectrometry in tandem (GC-MS/MS). A factorial design was used to optimize the extraction procedure. Method validation presented recoveries from 70.1% to 120.0% with RSD<20% and method limit of detection ranged from 0.3 to 7.5 µg kg(-1), showing good accuracy and precision. This method was successfully applied to the analysis of fish fillet from different species and residues of bisphenol A, chlorpyrifos and bifenthrin were detected. The proposed method proved to be effective for the determination of EDCs in fish fillet at very low concentration levels. © 2013 Elsevier B.V. All rights reserved.
Shelver, Weilin L; Chakrabarty, Shubhashis; Smith, David J
2017-03-01
Sows (n = 126) were administered penicillin G; urine, collected at slaughter, was screened by kidney inhibition swab (KIS; 4 h testing time) and then stored at -80 °C (∼1200 days) until analysis by lateral flow assay (LF, ∼5 min testing time) and tandem quadrupole LC-MS/MS (TQ) analysis. The stability of penicillin in urine during storage was verified using TQ analyses. Quantitative results were well-correlated (R 2 = 0.98) with only a ∼10% decrease in penicillin concentration during the 3-year storage period. KIS retesting of stored samples returned results consistent with the original analyses. Lateral flow assay results were highly correlated with the KIS and TQ results. A KIS positive sample, which was not confirmed by TQ or LF, was assayed by Triple-TOF LC-MS to determine the cause of the apparent false positive. This study suggests LF can be used to quickly and efficiently screen for penicillin G residues before slaughter.
Begou, O; Kontou, A; Raikos, N; Sarafidis, K; Roilides, E; Papadoyannis, I N; Gika, H G
2017-03-15
The development and validation of an ultra-high pressure liquid chromatography (UHPLC) tandem mass spectrometry (MS/MS) method was performed with the aim to be applied for the quantification of plasma teicoplanin concentrations in neonates. Pharmacokinetic data of teicoplanin in the neonatal population is very limited, therefore, a sensitive and reliable method for the determination of all isoforms of teicoplanin applied in a low volume of sample is of real importance. Teicoplanin main components were extracted by a simple acetonitrile precipitation step and analysed on a C18 chromatographic column by a triple quadrupole MS with electrospray ionization. The method provides quantitative data over a linear range of 25-6400ng/mL with LOD 8.5ng/mL and LOQ 25ng/mL for total teicoplanin. The method was applied in plasma samples from neonates to support pharmacokinetic data and proved to be a reliable and fast method for the quantification of teicoplanin concentration levels in plasma of infants during therapy in Intensive Care Unit. Copyright © 2016 Elsevier B.V. All rights reserved.
Zhou, Ying; Jiang, Ji; Hu, Pei; Wang, Hongyun
2014-12-01
A rapid, simple and validated method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) has been developed for the determination of granisetron in human plasma. Plasma samples were pre-purified by protein precipitation procedure. The chromatographic separation was achieved with Synergi Polar-RP (75 × 2 mm, 4 µm) column using a mixture of 5 mm pH4.0 ammonium formate and methanol (300:316, v/v) under isocratic conditions at a flow rate of 0.3 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode using positive electrospray ionization. The analysis time was about 2.5 min. The method was fully validated over the concentration range 0.1-10 ng/mL. The lower limit of quantification was 0.1 ng/mL. Inter- and intra-batch precision was <6.1% and the accuracy was within 95.6-100.0%. The mean extraction recovery was 96.3%. Selectivity, matrix effect and stability were also validated. The method was applied to the comparative pharmacokinetic study of granisetron in Chinese healthy subjects. Copyright © 2014 John Wiley & Sons, Ltd.
You, Chao; Song, Lili; Xu, Baiqing; Gao, Shaopeng
2016-02-01
A method is developed for determination of levoglucosan at trace concentration levels in complex matrices of snow and ice samples. This method uses an injection mixture comprising acetonitrile and melt sample at a ratio of 50/50 (v/v). Samples are analyzed using ultra-performance liquid chromatography system combined with triple tandem quadrupole mass spectrometry (UPLC-MS/MS). Levoglucosan is analyzed on BEH Amide column (2.1 mm × 100 mm, 1.7 um), and a Z-spray electrospray ionization source is used for levoglucosan ionization. The polyether sulfone filter is selected for filtrating insoluble particles due to less impact on levoglucosan. The matrix effect is evaluated by using a standard addition method. During the method validation, limit of detection (LOD), linearity, recovery, repeatability and reproducibility were evaluated using standard addition method. The LOD of this method is 0.11 ng mL(-1). Recoveries vary from 91.2% at 0.82 ng mL(-1) to 99.3% at 4.14 ng mL(-1). Repeatability ranges from 17.9% at a concentration of 0.82 ng mL(-1) to 2.8% at 4.14 ng mL(-1). Reproducibility ranges from 15.1% at a concentration of 0.82 ng mL(-1) to 1.9% at 4.14 ng mL(-1). This method can be implemented using less than 0.50 mL sample volume in low and middle latitude regions like the Tibetan Plateau. Copyright © 2015 Elsevier B.V. All rights reserved.
Uclés, S; Lozano, A; Sosa, A; Parrilla Vázquez, P; Valverde, A; Fernández-Alba, A R
2017-11-01
Gas and liquid chromatography coupled to triple quadrupole tandem mass spectrometry are currently the most powerful tools employed for the routine analysis of pesticide residues in food control laboratories. However, whatever the multiresidue extraction method, there will be a residual matrix effect making it difficult to identify/quantify some specific compounds in certain cases. Two main effects stand out: (i) co-elution with isobaric matrix interferents, which can be a major drawback for unequivocal identification, and therefore false negative detections, and (ii) signal suppression/enhancement, commonly called the "matrix effect", which may cause serious problems including inaccurate quantitation, low analyte detectability and increased method uncertainty. The aim of this analytical study is to provide a framework for evaluating the maximum expected errors associated with the matrix effects. The worst-case study contrived to give an estimation of the extreme errors caused by matrix effects when extraction/determination protocols are applied in routine multiresidue analysis. Twenty-five different blank matrices extracted with the four most common extraction methods used in routine analysis (citrate QuEChERS with/without PSA clean-up, ethyl acetate and the Dutch mini-Luke "NL" methods) were evaluated by both GC-QqQ-MS/MS and LC-QqQ-MS/MS. The results showed that the presence of matrix compounds with isobaric transitions to target pesticides was higher in GC than under LC in the experimental conditions tested. In a second study, the number of "potential" false negatives was evaluated. For that, ten matrices with higher percentages of natural interfering components were checked. Additionally, the results showed that for more than 90% of the cases, pesticide quantification was not affected by matrix-matched standard calibration when an interferent was kept constant along the calibration curve. The error in quantification depended on the concentration level. In a third study, the "matrix effect" was evaluated for each commodity/extraction method. Results showed 44% of cases with suppression/enhancement for LC and 93% of cases with enhancement for GC. Copyright © 2017 Elsevier B.V. All rights reserved.
Careri, M; Costa, A; Elviri, L; Lagos, J-B; Mangia, A; Terenghi, M; Cereti, A; Garoffo, L Perono
2007-11-01
A liquid chromatography-electrospray-tandem mass spectrometry (LC-ESI-MS-MS) method based on the detection of biomarker peptides from allergenic proteins was devised for confirming and quantifying peanut allergens in foods. Peptides obtained from tryptic digestion of Ara h 2 and Ara h 3/4 proteins were identified and characterized by LC-MS and LC-MS-MS with a quadrupole-time of flight mass analyzer. Four peptides were chosen and investigated as biomarkers taking into account their selectivity, the absence of missed cleavages, the uniform distribution in the Ara h 2 and Ara h 3/4 protein isoforms together with their spectral features under ESI-MS-MS conditions, and good repeatability of LC retention time. Because of the different expression levels, the selection of two different allergenic proteins was proved to be useful in the identification and univocal confirmation of the presence of peanuts in foodstuffs. Using rice crisp and chocolate-based snacks as model food matrix, an LC-MS-MS method with triple quadrupole mass analyzer allowed good detection limits to be obtained for Ara h 2 (5 microg protein g(-1) matrix) and Ara h 3/4 (1 microg protein g(-1) matrix). Linearity of the method was established in the 10-200 microg g(-1) range of peanut proteins in the food matrix investigated. Method selectivity was demonstrated by analyzing tree nuts (almonds, pecan nuts, hazelnuts, walnuts) and food ingredients such as milk, soy beans, chocolate, cornflakes, and rice crisp.
Differentially pumped dual linear quadrupole ion trap mass spectrometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owen, Benjamin C.; Kenttamaa, Hilkka I.
The present disclosure provides a new tandem mass spectrometer and methods of using the same for analyzing charged particles. The differentially pumped dual linear quadrupole ion trap mass spectrometer of the present disclose includes a combination of two linear quadrupole (LQIT) mass spectrometers with differentially pumped vacuum chambers.
NASA Astrophysics Data System (ADS)
Geib, Timon; Sleno, Lekha; Hall, Rabea A.; Stokes, Caroline S.; Volmer, Dietrich A.
2016-08-01
We describe a systematic comparison of high and low resolution LC-MS/MS assays for quantification of 25-hydroxyvitamin D3 in human serum. Identical sample preparation, chromatography separations, electrospray ionization sources, precursor ion selection, and ion activation were used; the two assays differed only in the implemented final mass analyzer stage; viz. high resolution quadrupole-quadrupole-time-of-flight (QqTOF) versus low resolution triple quadrupole instruments. The results were assessed against measured concentration levels from a routine clinical chemiluminescence immunoassay. Isobaric interferences prevented the simple use of TOF-MS spectra for extraction of accurate masses and necessitated the application of collision-induced dissociation on the QqTOF platform. The two mass spectrometry assays provided very similar analytical figures of merit, reflecting the lack of relevant isobaric interferences in the MS/MS domain, and were successfully applied to determine the levels of 25-hydroxyvitamin D for patients with chronic liver disease.
Interfacing an aspiration ion mobility spectrometer to a triple quadrupole mass spectrometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adamov, Alexey; Viidanoja, Jyrki; Kaerpaenoja, Esko
2007-04-15
This article presents the combination of an aspiration-type ion mobility spectrometer with a mass spectrometer. The interface between the aspiration ion mobility spectrometer and the mass spectrometer was designed to allow for quick mounting of the aspiration ion mobility spectrometer onto a Sciex API-300 triple quadrupole mass spectrometer. The developed instrumentation is used for gathering fundamental information on aspiration ion mobility spectrometry. Performance of the instrument is demonstrated using 2,6-di-tert-butyl pyridine and dimethyl methylphosphonate.
Martinez, Ana Flávia Canovas; Moraes, Luiz Alberto Beraldo
2015-03-01
The fungus Paecilomyces lilacinus produces leucinostatins—peptaibiotics that exert a range of biological activities including antimalarial, antiviral, antitumor and phytotoxicity. In this paper, we developed an analytical method employing LC-MS/MS in the precursor ion and product ion scan modes to elucidate five new leucinostatins. Direct Infusion (DI-MS) helped to identify the most abundant leucinostatins: F, D B2, S, A and K. MS/MS analysis using a triple quadrupole operating at different scan modes is a versatile tool to study natural products, especially peptaibiotics. Although DI-MS full-scan analysis is rapid and sensitive, it cannot distinguish between peptide isomers. On the other hand, LC-MS/MS operated in the precursor ion and product ion modes is time consuming, but allows identifying the structure of isomers or isobar in crude extracts.
Determination of glutathione in spruce needles by liquid chromatography/tandem mass spectrometry.
Gucek, Marjan; Makuc, Simon; Mlakar, Anita; Bericnik-Vrbovsek, Julija; Marsel, Joze
2002-01-01
For the determination of glutathione (GSH) and its oxidized form (GSSG) in spruce needles their electrospray mass and MS/MS spectra were recorded with an ion trap mass spectrometer (ITMS, LCQ, Finnigan) and a triple stage quadrupole mass spectrometer (TSQ, Quattro II, Micromass). A study of the stability of GSH in aqueous solutions shows the presence of dimeric and trimeric forms of GSH, as well as GSSG, GSH-sulfonate and GSH-sulfinic acid. The same components were also found in extracts of spruce needles. We developed an assay which is suitable for monitoring low concentrations of GSH and similar compounds in plant tissues, employing the sensitivity and specificity of LC/MS/MS. Preliminary results on the mass spectrometric determination of GSH in spruce needles are given. Copyright 2002 John Wiley & Sons, Ltd.
Direct analysis of [6,6-(2)H2]glucose and [U-(13)C6]glucose dry blood spot enrichments by LC-MS/MS.
Coelho, Margarida; Mendes, Vera M; Lima, Inês S; Martins, Fátima O; Fernandes, Ana B; Macedo, M Paula; Jones, John G; Manadas, Bruno
2016-06-01
A liquid chromatography tandem mass spectrometry (LC-MS/MS) using multiple reaction monitoring (MRM) in a triple-quadrupole scan mode was developed and comprehensively validated for the determination of [6,6-(2)H2]glucose and [U-(13)C6]glucose enrichments from dried blood spots (DBS) without prior derivatization. The method is demonstrated with dried blood spots obtained from rats administered with a primed-constant infusion of [U-(13)C6]glucose and an oral glucose load enriched with [6,6-(2)H2]glucose. The sensitivity is sufficient for analysis of the equivalent to <5μL of blood and the overall method was accurate and precise for the determination of DBS isotopic enrichments. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Prada, Svitlana V.; Bohme, Diethard K.; Baranov, Vladimir I.
2007-03-01
We report ion-mobility measurements with a modified triple quadrupole mass spectrometer fitted with an ion molecule reactor (IMR) designed to investigate ion molecule reactivity in organic mass spectrometry. Functionalized pentacene ions, which are generally unreactive were chosen for study to decouple drift/diffusion effects from reactivity (including clustering). The IMR is equipped with a variable axial electrostatic drift field (ADF) and is able to trap ions. These capabilities were successfully employed in the measurement of ion mobilities in different modes of IMR operation. Theoretical modeling of the drift dynamics and the special localization of the large ion packet was successfully implemented. The contribution of the quadrupole RF field to the drift dynamics also was taken into consideration.
Wu, Ya-Hsueh; Wu, Ming-Ling; Lin, Chun-Chi; Chu, Wei-Lan; Yang, Chen-Chang; Lin, Robert Tate; Deng, Jou-Fang
2012-02-15
A simple and rapid assay based on hydrophilic interaction liquid chromatography with tandem mass spectrometry has been first developed and validated for simultaneous determination of caprolactam (CA) and 6-aminocaproic acid (6-ANCA) in human urine using 8-aminocaprylic acid as internal standard. A 20μL aliquot of urine was injected directly into the liquid chromatography tandem mass spectrometry (LC-MS-MS) system. The analytes were separated on a Phenomenex Luna HILIC column with gradient elution. Detection was performed on Triple Quadrupole LC-MS in positive ions multiple reaction monitoring mode using electrospray ionization. The calibration curves were linear (r(2)≥0.995) over the concentration range from 62.5 to 1250ng/mL for CA and 31.25 to 1000ng/mL for 6-ANCA. The detection limits of CA and 6-ANCA were 62.5 and 15.6ng/mL, respectively. The intra-day and inter-day precisions were within 8.7% and 9.9%, respectively. The intra-day and inter-day accuracy were between 5.3% and 3.5%, and between 6.1% and 6.6%, respectively. The method proved to be simple and time efficient, and was successfully applied to evaluate the kinetics of caprolactam in one unusual case of caprolactam poisoning. Copyright © 2011 Elsevier B.V. All rights reserved.
Truta, Liliana; Castro, André L; Tarelho, Sónia; Costa, Pedro; Sales, M Goreti F; Teixeira, Helena M
2016-09-05
Depression is among the most prevalent psychiatric disorders of our society, leading to an increase in antidepressant drug consumption that needs to be accurately determined in whole blood samples in Forensic Toxicology Laboratories. For this purpose, this work presents a new gas chromatography tandem mass spectrometry (GC-MS/MS) method targeting the simultaneous and rapid determination of 14 common Antidepressants in whole blood: 13 Antidepressants (amitriptyline, citalopram, clomipramine, dothiepin, fluoxetine, imipramine, mianserin, mirtazapine, nortryptiline, paroxetine, sertraline, trimipramine and venlafaxine) and 1 Metabolite (N-desmethylclomipramine). Solid-phase extraction was used prior to chromatographic separation. Chromatographic and MS/MS parameters were selected to improve sensitivity, peak resolution and unequivocal identification of the eluted analyte. The detection was performed on a triple quadrupole tandem MS in selected ion monitoring (SIM) mode in tandem, using electronic impact ionization. Clomipramine-D3 and trimipramine-D3 were used as deutered internal standards. The validation parameters included linearity, limits of detection, lower limit of quantification, selectivity/specificity, extraction efficiency, carry-over, precision and robustness, and followed internationally accepted guidelines. Limits of quantification and detection were lower than therapeutic and sub-therapeutic concentration ranges. Overall, the method offered good selectivity, robustness and quick response (<16min) for typical concentration ranges, both for therapeutic and lethal levels. Copyright © 2016 Elsevier B.V. All rights reserved.
Nahar, Limon Khatun; Cordero, Rosa Elena; Nutt, David; Lingford-Hughes, Anne; Turton, Samuel; Durant, Claire; Wilson, Sue; Paterson, Sue
2016-01-01
Abstract A highly sensitive and fully validated method was developed for the quantification of baclofen in human plasma. After adjusting the pH of the plasma samples using a phosphate buffer solution (pH 4), baclofen was purified using mixed mode (C8/cation exchange) solid-phase extraction (SPE) cartridges. Endogenous water-soluble compounds and lipids were removed from the cartridges before the samples were eluted and concentrated. The samples were analyzed using triple-quadrupole liquid chromatography–tandem mass spectrometry (LC–MS-MS) with triggered dynamic multiple reaction monitoring mode for simultaneous quantification and confirmation. The assay was linear from 25 to 1,000 ng/mL (r2 > 0.999; n = 6). Intraday (n = 6) and interday (n = 15) imprecisions (% relative standard deviation) were <5%, and the average recovery was 30%. The limit of detection of the method was 5 ng/mL, and the limit of quantification was 25 ng/mL. Plasma samples from healthy male volunteers (n = 9, median age: 22) given two single oral doses of baclofen (10 and 60 mg) on nonconsecutive days were analyzed to demonstrate method applicability. PMID:26538544
Bhatt, Mitesh; Shah, Sanjay; Shivprakash
2010-06-01
A simple, rapid, sensitive and specific ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the quantification of ethosuximide in human plasma is described. Analyte was chromatographed on a Hypersil Gold C18 column (100 mm x 2.1 mm, i.d., 1.9 microm) with isocratic elution at a flow rate of 0.250 mL/min and pravastatin was used as the internal standard. The assay involves a simple solid-phase extraction procedure of 0.25 mL human plasma and the analysis was performed on a triple-quadrupole tandem mass spectrometer by MRM mode via electrospray ionization (ESI). The method was linear in the concentration range of 0.25-60.0 microg/mL. The lower limit of quantification (LLOQ) was 0.25 microg/mL. The within- and between-day precision and accuracy of the quality control samples were within 10.0%. The recovery was 95.1% and 94.4% for ethosuximide and pravastatin, respectively. The analysis time for each sample was 1.8 min. The method was highly reproducible and gave peaks with excellent chromatography properties. Copyright 2010 Elsevier B.V. All rights reserved.
Zheng, Shuilian; Wu, Huizhen; Li, Zuguang; Wang, Jianmei; Zhang, Hu; Qian, Mingrong
2015-01-01
A one-step ultrasound/microwave-assisted solid-liquid-solid dispersive extraction procedure was used for the simultaneous determination of eight neonicotinoids (dinotefuran, nitenpyram, thiamethoxam, clothianidin, imidacloprid, acetamiprid, thiacloprid, imidaclothiz) in dried Dendrobium officinale by liquid chromatography combined with electrospray ionization triple quadrupole tandem mass spectrometry in multiple reaction monitoring mode. The samples were quickly extracted by acetonitrile and cleaned up by the mixed dispersing sorbents including primary secondary amine, C18 , and carbon-GCB. Parameters that could influence the ultrasound/microwave-assisted extraction efficiency such as microwave irradiation power, ultrasound irradiation power, temperature, and solvent were investigated. Recovery studies were performing well (70.4-113.7%) at three examined spiking levels (10, 50, and 100 μg/kg). Meanwhile, the limits of quantification for the neonicotinoids ranged from 0.87 to 1.92 μg/kg. The method showed good linearity in the concentration range of 1-100 μg/L with correlation coefficients >0.99. This quick and useful analytical method could provide a basis for monitoring neonicotinoid insecticide residues in herbs. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hu, Ziyan; Zou, Qiaogen; Tian, Jixin; Sun, Lili; Zhang, Zunjian
2011-12-15
A rapid and sensitive method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of codeine, ephedrine, guaiphenesin and chlorpheniramine in beagle dog plasma has been developed and validated. Following liquid-liquid extraction, the analytes were separated on a reversed-phase C(18) column (150 mm × 2.0 mm, 3 μm) using formic acid:10 mM ammonium acetate:methanol (0.2:62:38, v/v/v) as mobile phase at a flow rate of 0.2 mL/min and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode. The method was linear for all analytes over the following concentration (ng/mL) ranges: codeine 0.08-16; ephedrine 0.8-160; guaiphenesin 80-16,000; chlorpheniramine 0.2-40. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. It is the first time that the validated HPLC-MS/MS method was successfully applied to a bioequivalence study in 6 healthy beagle dogs. Copyright © 2011 Elsevier B.V. All rights reserved.
Mezcua, Milagros; Ferrer, Carmen; García-Reyes, Juan F; Martínez-Bueno, María Jesús; Albarracín, Micaela; Claret, María; Fernández-Alba, Amadeo R
2008-05-01
In this work, two analytical methods based on liquid chromatography coupled to electrospray time-of-flight mass spectrometry (LC/ESI-TOFMS) and tandem mass spectrometry (LC/ESI-MS/MS) are described for the identification, confirmation and quantitation of three insecticides non-authorized in the European Union (nitenpyram, isocarbophos and isofenphos-methyl) but detected in recent monitoring programmes in pepper samples. The proposed methodologies involved a sample extraction procedure using liquid-liquid partition with acetonitrile followed by a cleanup step based on dispersive solid-phase extraction. Recovery studies performed on peppers spiked at different fortification levels (10 and 50 microg kg(-1)) yielded average recoveries in the range 76-100% with relative standard deviation (RSD) (%) values below 10%. Identification, confirmation and quantitation were carried out by LC/TOFMS and LC/MS/MS using a hybrid triple quadrupole linear ion trap (QqLIT) instrument in multiple-reaction monitoring (MRM) mode. The obtained limits of quantitation (LOQs) were in the range 0.1-5 microg kg(-1), depending on each individual technique. Finally, the proposed methods were successfully applied to the analysis of suspected pepper samples. Copyright (c) 2008 John Wiley & Sons, Ltd.
Shan, Chen-Xiao; Cui, Xiao-Bing; Yu, Sheng; Chai, Chuan; Wen, Hong-Mei; Wang, Xin-Zhi; Sun, Xue
2016-01-01
3,4-Divanillyltetrahydrofuran is the main active ingredient of nettle root which can increase steroid hormones in the bloodstream for many of bodybuilders. To better understand its pharmacological activities, we need to determine its pharmacokinetic profiles. In this study, a rapid and sensitive ultra-fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) method has been developed for the determination of 3,4-divanillyltetrahydrofuran in the plasma of rats. Chromatographic separation was performed on a C18 column at 40°C, with a gradient elution consisting of methanol and water containing 0.3% (v/v) formic acid at a flow rate of 0.8mL/min. The detection was performed using an electrospray triple-quadrupole MS/MS via positive ion multiple reaction monitoring mode. The lower limits-of-quantification determined were 0.5ng/mL. The intra- and inter-day precision (RSD%) was found to be within 15% and the accuracy (RE%) ranged from -4.0% to 7.0%. This simple yet sensitive method was fully validated and could be successfully applied to the study on pharmacokinetics of 3, 4-divanillyltetrahydrofuran. Copyright © 2015 Elsevier B.V. All rights reserved.
Weng, Zebin; Zeng, Fei; Zhu, Zhenhua; Qian, Dawei; Guo, Sheng; Wang, Hanqing; Duan, Jin-Ao
2018-07-15
The root of Sophora flavescens Ait. has long been used as a crude drug in China and other Asian countries for thousands of years. The quinolizidine alkaloids and flavonoids are considered as the main bioactive components in this plant. To determine the distribution and content of the flavonoids in different organs of this plant, a rapid, sensitive and reproducible method was established using ultra-high-performance liquid chromatography coupled with a triple quadrupole electrospray tandem mass spectrometry. A total of sixteen flavonoids including five different types (isoflavones, pterocarpans, flavones, flavonols and prenylflavonoids) were simultaneously determined in 10 min. The established method was fully validated in terms of linearity, sensitivity, precision, repeatability as well as recovery and successfully applied in the methanolic extracts of S. flavescens parts (root, stem, leaf, pod and seed). The analysis results indicated that the distribution and contents of different type of flavonoids showed remarkable differences among the five organs of S. flavescens. This study might be useful for the rational utilization of S. flavescens resource. Copyright © 2018 Elsevier B.V. All rights reserved.
Lashgari, Maryam; Lee, Hian Kee
2014-11-21
In the current study, a simple, fast and efficient combination of protein precipitation and micro-solid phase extraction (μ-SPE) followed by liquid chromatography-triple quadrupole tandem mass spectrometry (LC-MS/MS) was developed for the determination of perfluorinated carboxylic acids (PFCAs) in fish fillet. Ten PFCAs with different hydrocarbon chain lengths (C5-C14) were analysed simultaneously using this method. Protein precipitation by acetonitrile and μ-SPE by surfactant-incorporated ordered mesoporous silica were applied to the extraction and concentration of the PFCAs as well as for removal of interferences. Determination of the PFCAs was carried out by LC-MS/MS in negative electrospray ionization mode. MS/MS parameters were optimized for multiple reaction monitoring of the analytes. (13)C mass labelled PFOA as a stable-isotopic internal standard, was used for calibration. The detection limits of the method ranged from 0.97 ng/g to 2.7 ng/g, with a relative standard deviation of between 5.4 and 13.5. The recoveries were evaluated for each analyte and were ranged from 77% to 120%. The t-test at 95% confidence level showed that for all the analytes, the relative recoveries did not depend on their concentrations in the explored concentration range. The effect of the matrix on MS signals (suppression or enhancement) was also evaluated. Contamination at low levels was detected for some analytes in the fish samples. The protective role of the polypropylene membrane used in μ-SPE in the elimination of matrix effects was evaluated by parallel experiments in classical dispersive solid phase extraction. The results evidently showed that the polypropylene membrane was significantly effective in reducing matrix effects. Copyright © 2014 Elsevier B.V. All rights reserved.
2016-02-01
NOTES 14. ABSTRACT: The electron impact and collision-induced- dissociation mass spectra of 1-(2-chloroethoxy)-2-[(2-chloroethyl)thio] ethane and 10...Collision-ion dissociation (CID) Triple-quadrupole mass spectrometry (QQQ) 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT...ratio, 10:1), and a 1.0 µL volume of sample was placed on the column. Nitrogen was used as the collision gas for the collision-induced dissociation (CID
Brandt, Simon D; Elliott, Simon P; Kavanagh, Pierce V; Dempster, Nicola M; Meyer, Markus R; Maurer, Hans H; Nichols, David E
2015-04-15
Substances based on the N-(2-methoxybenzyl)phenethylamine template ('NBOMe' derivatives) play an important role in medicinal research but some of these derivatives have also appeared as 'research chemicals' for recreational use which has attracted attention worldwide. A major challenge associated with newly emerging substances includes the lack of analytical data and the ability to correctly identify positional isomers. Six N-benzylphenethylamines based on the 2,5-dimethoxy-4-iodophenethylamine structure ('25I') and twelve substituted N-benzyl-5-methoxytryptamines ('5MT') have been prepared and extensively characterized. Techniques used for characterization were gas chromatography/ion trap mass spectrometry in electron and chemical ionization mode, liquid chromatography/diode array detection (DAD), infrared spectroscopy, electrospray high mass accuracy quadrupole time-of-flight tandem mass spectrometry, and triple quadrupole tandem mass spectrometry. The characterization of 18 'NBOMe' compounds provided a comprehensive collection of chromatographic and spectral data. Four groups of three positional isomers, i.e. 25I-NB2OMe, 25I-NB3OMe, 25I-NB4OMe, 25I-NB2B, 25I-NB3B, 25I-NB4B and their 5-methoxytryptamine counterparts, were included and assessed for ability to obtain differentiation. Six meta-substituted N-benzyl derivatives of 5-methoxytryptamine (CF3, F, CH3, Cl, I, SCH3) were also studied. The implementation of mass spectral techniques was helpful for the differentiation between isomers, for example, when considering the difference in a number of ion ratios. This was considered beneficial in cases where chromatographic separation was only partially achieved under liquid chromatography (LC) conditions. The use of LC/DAD analysis was also found to be valuable for this particular purpose, which confirmed the integrative value of complementary techniques used in areas related to forensic toxicology. Copyright © 2015 John Wiley & Sons, Ltd.
Al-Dulaymi, M; El-Aneed, A
2017-06-01
Diquaternary ammonium gemini surfactants have emerged as effective gene delivery vectors. A novel series of 11 peptide-modified compounds was synthesized, showing promising results in delivering genetic materials. The purpose of this work is to elucidate the tandem mass spectrometric (MS/MS) dissociation behavior of these novel molecules establishing a generalized MS/MS fingerprint. Exact mass measurements were achieved using a hybrid quadrupole orthogonal time-of-flight mass spectrometer, and a multi-stage MS/MS analysis was conducted using a triple quadrupole-linear ion trap mass spectrometer. Both instruments were operated in the positive ionization mode and are equipped with electrospray ionization. Abundant triply charged [M+H] 3+ species were observed in the single-stage analysis of all the evaluated compounds with mass accuracies of less than 8 ppm in mass error. MS/MS analysis showed that the evaluated gemini surfactants exhibited peptide-related dissociation characteristics because of the presence of amino acids within the compounds' spacer region. In particular, diagnostic product ions were originated from the neutral loss of ammonia from the amino acids' side chain resulting in the formation of pipecolic acid at the N-terminus part of the gemini surfactants. In addition, a charge-directed amide bond cleavage was initiated by the amino acids' side chain producing a protonated α-amino-ε-caprolactam ion and its complimentary C-terminus ion that contains quaternary amines. MS/MS and MS 3 analysis revealed common fragmentation behavior among all tested compounds, resulting in the production of a universal MS/MS fragmentation pathway. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Sel, Sabriye; Öztürk Er, Elif; Bakırdere, Sezgin
2017-12-01
A highly sensitive and simple diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method was developed for the simultaneous determination of niacin and pyridoxine in pharmaceutical drugs, tap water, and wastewater samples. To determine the in vivo behavior of niacin and pyridoxine, analytes were subjected to simulated gastric conditions. The calibration plots of the diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method showed good linearity over a wide concentration range with close to 1.0 correlation coefficients for both analytes. The limit of detection/limit of quantitation values for liquid chromatography quadrupole time-of-flight tandem mass spectrometry analysis were 1.98/6.59 and 1.3/4.4 μg/L for niacin and pyridoxine, respectively, while limit of detection/limit of quantitation values for niacin and pyridoxine in high-performance liquid chromatography analysis were 3.7/12.3 and 5.7/18.9 μg/L, respectively. Recovery studies were also performed to show the applicability of the developed methods, and percentage recovery values were found to be 90-105% in tap water and 94-97% in wastewater for both analytes. The method was also successfully applied for the qualitative and quantitative determination of niacin and pyridoxine in drug samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Mari, Angela; Montoro, Paola; D'Urso, Gilda; Macchia, Mario; Pizza, Cosimo; Piacente, Sonia
2015-01-01
Food supplements based on Vitex agnus castus L. (Verbenaceae) fruits, also known as chasteberry, are routinely used by women against somatic and psychic premenstrual symptoms such as depression, sadness or irritability. With the aim of highlighting the differences in the chemical profiles of cultivated fruits and different parts of wild plants (fruits, leaves and sprouts) of V. agnus castus, a method concerning with the quali-quantitative study of the derived hydroalcoholic extracts was carried out by using high-performance liquid chromatography coupled to electrospray negative ionization Orbitrap multicollisional high resolution mass spectrometry (LC/ESI/(Orbitrap)MS(n)) and high-performance liquid chromatography coupled to electrospray negative ionization triple quadrupole tandem mass spectrometry (LC/ESI/(QqQ)MS) in multiple reaction monitoring (MRM) mode. Copyright © 2014 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owen, Benjamin C.; Kenttamaa, Hilkka I.
The present disclosure provides a new tandem mass spectrometer and methods of using the same for analyzing charged particles. The differentially pumped dual linear quadrupole ion trap mass spectrometer of the present disclose includes a combination of two linear quadrupole (LQIT) mass spectrometers with differentially pumped vacuum chambers.
Boix, C; Ibáñez, M; Sancho, J V; Niessen, W M A; Hernández, F
2013-10-01
Omeprazole is one of the most consumed pharmaceuticals around the world. However, this compound is scarcely detected in urban wastewater and surface water. The absence of this pharmaceutical in the aquatic ecosystem might be due to its degradation in wastewater treatment plants, as well as in receiving water. In this work, different laboratory-controlled degradation experiments have been carried out on surface water in order to elucidate generated omeprazole transformation products (TPs). Surface water spiked with omeprazole was subjected to hydrolysis, photo-degradation under both sunlight and ultraviolet radiation and chlorination. Analyses by liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (LC-QTOF MS) permitted identification of up to 17 omeprazole TPs. In a subsequent step, the TPs identified were sought in surface water and urban wastewater by LC-QTOF MS and by LC coupled to tandem mass spectrometry with triple quadrupole. The parent omeprazole was not detected in any of the samples, but four TPs were found in several water samples. The most frequently detected compound was OTP 5 (omeprazole sulfide), which might be a reasonable candidate to be included in monitoring programs rather than the parent omeprazole. Copyright © 2013 John Wiley & Sons, Ltd.
Wu, Songyan; Zhang, Yaqing; Zhang, Zunjian; Song, Rui
2017-10-01
Emodin is the representative form of rhubarb, which is widely used in traditional Chinese medicine for the treatment of purgative, anti-inflammatory, antioxidative and antiviral, etc. Previous reports demonstrated that emodin glucuronide was the major metabolite in plasma. Owing to the extensive conjugation reactions of polyphenols, the aim of this study was to identify the metabolites of emodin in rat bile and urine. Neutral loss and precursor ion scan methods of triple-quadrupole mass spectrometer revealed 13 conjugated metabolites in rat bile and 22 metabolites in rat urine, which included four phase I and 18 phase II metabolites. The major metabolites in rat biosamples were emodin glucuronoconjugates. Moreover, rhein monoglucuronide, chrysophanol monoglucuronide and rhein sulfate were proposed for the first time after oral administration of emodin. Overall, liquid chromatography hybrid triple-quadrupole mass spectrometry analysis leads to the discovery of several novel emodin metabolites in rat bile and urine and underscores that conjugated with glucuronic acid is the main metabolic pathway. Copyright © 2017 John Wiley & Sons, Ltd.
García-Bermejo, Ángel; Ábalos, Manuela; Sauló, Jordi; Abad, Esteban; González, María José; Gómara, Belén
2015-08-19
This paper reports on the optimisation, characterisation, validation and applicability of gas chromatography coupled to triple quadrupole mass spectrometry in its tandem operation mode (GC-QqQ(MS/MS) for the quantification of polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs, dioxins) and dioxin-like polychlorinated biphenyls (DL-PCBs) in environmental and food matrices. MS/MS parameters were selected to achieve the high sensitivity and selectivity required for the analysis of this type of compounds and samples. Good repeatability for areas (RSD = 1-10%, for PCDD/Fs and DL-PCBs) and for ion transition ratios (RSD = 0.3-10%, for PCDD/Fs, and 0.2-15%, for DL-PCBs) and low instrumental limits of detection, 0.07-0.75 pg μL(-1) (for dioxins) and 0.05-0.63 pg μL(-1) (for DL-PCBs), were obtained. A comparative study of the congener specific determination using both GC-QqQ(MS/MS) and gas chromatography-high resolution mass spectrometry (GC-HRMS) was also performed by analysing several fortified samples and certified reference materials (CRMs) with low (feed and foodstuffs), median (sewage sludge) and high (fly ash) toxic equivalency (TEQ) concentration levels, i.e. 0.60, 1.83, 72.9 and 3609 pg WHO-TEQ(PCDD/Fs) g(-1). The agreement between the results obtained for the total TEQs (dioxins) on GC-QqQ(MS/MS) and GC-HRMS in all the investigated samples were within the range of ±4%, and that of DL-PCBs at concentration levels of 0.84 pg WHO-TEQs (DL-PCBs) g(-1), in the case of feedstuffs, was 0.11%. Both instrumental methods have similar and comparable linearity, precision and accuracy. The GC-QqQ(MS/MS) sensitivity, lower than that of GC-HRMS, is good enough (iLODs in the down to low pg levels) to detect the normal concentrations of these compounds in food and environmental samples. These results make GC-QqQ(MS/MS) suitable for the quantitative analysis of dioxins and DL-PCBs and a real alternative tool to the reference sector HRMS instruments. Copyright © 2015 Elsevier B.V. All rights reserved.
Campo, Laura; Hanchi, Mariem; Olgiati, Luca; Polledri, Elisa; Consonni, Dario; Zrafi, Ines; Saidane-Mosbahi, Dalila; Fustinoni, Silvia
2016-07-01
Occupational exposures during iron and steel founding have been classified as carcinogenic to humans, and the exposure to polycyclic aromatic hydrocarbons (PAHs) in this industrial setting may contribute to cancer risk. The occupational exposure to PAHs was assessed in 93 male workers at an electric steel foundry in Tunisia by biomonitoring, with the aims of characterizing the excretion profile and investigating the influence of job title and personal characteristics on the biomarkers. Sixteen 2-6 ring unmetabolized PAHs (U-PAHs) and eight hydroxylated PAH metabolites (OHPAHs) were analyzed by gas chromatography-triple quadrupole tandem mass spectrometry and liquid chromatography triple quadrupole tandem mass spectrometry, respectively. Among U-PAHs, urinary naphthalene (U-NAP) was the most abundant compound (median level: 643ng l(-1)), followed by phenanthrene (U-PHE, 18.5ng l(-1)). Urinary benzo[a]pyrene (U-BaP) level was <0.30ng l(-1) Among OHPAHs, 2-hydroxynaphthalene (2-OHNAP) was the most abundant metabolite (2.27 µg l(-1)). Median 1-hydroxypyrene (1-OHPYR) was 0.52 µg l(-1) Significant correlations among urinary biomarkers were observed, with Pearson's r ranging from 0.177 to 0.626. 1-OHPYR was correlated to benzo[a]pyrene, but not to five- and six-rings PAHs. A multiple linear regression model showed that job title was a significant determinant for almost all U-PAHs. In particular, employees in the steel smelter workshop had higher levels of high-boiling U-PAHs and lower levels of low-boiling U-PAHs than those of workers with other job titles. Among OHPAHs, this model was significant only for naphthols and 1-hydroxyphenanthrene (1-OHPHE). Smoking status was a significant predictor for almost all biomarkers. Among all analytes, U-PHE and 1-OHPHE were the less affected by tobacco smoke, and they were significantly correlated with both low- and high-molecular-weight compounds, and their levels were related to job titles, so they could be proposed as suitable biomarkers of PAH exposure at steel foundries. Based on 1-OHPYR levels, our findings show that occupational exposure of these workers was similar to that reported in recent studies of electric steel foundry workers. The multianalytic approach is useful in revealing different exposure levels among job titles. © The Author 2016. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Orrego-Lagarón, Naiara; Vallverdú-Queralt, Anna; Martínez-Huélamo, Miriam; Lamuela-Raventos, Rosa M; Escribano-Ferrer, Elvira
2016-02-20
Several biological activities (antioxidant, anti-inflammatory, anticarcinogenic) are attributed to naringenin (NAR)-a predominant flavonoid of citrus fruit and tomato-despite its low bioavailability after ingestion. NAR undergoes extensive metabolism when crossing the gastrointestinal tract, resulting in enteric, hepatic and microbial metabolites, some of them with recognized beneficial effects on human health. This study sought to provide new insights into the metabolism of NAR in regions of the gastrointestinal tract where it has been less studied: the stomach and colon. With this purpose, liquid chromatography coupled with an electrospray ionization hybrid linear ion trap quadrupole Orbitrap mass spectrometry technique (LC-ESI-LTQ-Orbitrap-MS) was used for an accurate identification of NAR metabolites, and liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) on a triple quadrupole was used for their identification and quantification. The combination of both analytical techniques provided a broader metabolic profile of NAR. As far as we know, this is the first in-depth metabolic profiling study of NAR in the stomach of mice. Three of the metabolites determined using the LC-LTQ-Orbitrap could not be identified by LC-ESI-MS/MS in stomach perfusion samples: apigenin, 3-(4-hydroxyphenyl) propionic acid and phloroglucinol. The number of colonic metabolites determined using the LTQ-Orbitrap-MS was more than twice the number identified by LC-ESI-MS/MS. Copyright © 2015 Elsevier B.V. All rights reserved.
Luo, Lanxin; Cui, Yan; Zhang, Shuting; Li, Lingxi; Suo, Hao; Sun, Baoshan
2017-11-15
Vidal Blanc grape (Vitis vinifera cv.) is the predominant white grape variety used for the production of icewine in China's Liaoning province. In this paper, the development and validation of the method by ultrahigh-performance liquid chromatography-tandem mass spectrometry has been performed for determination of the detailed phenolic composition in the skin, seed and stem of Vidal grapes. The validation of the method was realized by calculating the linearity, repeatability, precision, stability and the limits of detection (LOD) and quantification (LOQ) of standard solutions. All the curves exhibited good linearity (r 2 >0.9997) and the LOD and LOQ were in the range of 0.002-0.025 and 0.006-0.086μg/ml, respectively. Good repeatability (RSD<4.3%) and stability (RSD<3.7%) were also found. Results confirmed that the developed method was more effective and sensitive for simultaneous determination of the major phenolic compounds in Vidal grape pomace. The optimized and validated method of ultrahigh-performance liquid chromatography tandem two complementary techniques, fourier transform ion cyclotron resonance mass spectrometry and triple-quadrupole mass spectrometry, allowed to identify and quantify up to 35 phenolic compounds in Vidal grape pomace, which has, as far as we know, been reported this grapevine variety for the first time. Seeds, skins and stems exhibited different qualitative and quantitative phenolic profiles. These results provided useful information for recovery of phenolic antioxidants from different parts of icewine pomace. Copyright © 2017. Published by Elsevier B.V.
Bhatt, Mitesh; Shah, Sanjay
2010-11-01
A method based on ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) in combination with solid-phase extraction for sample pretreatment has been developed for the simultaneous analysis of amitriptyline and its main metabolite in human plasma. The extraction of the analytes from plasma samples was carried out by means of a selective SPE procedure using hydrophilic-lipophilic balance cartridges. The assay involves a simple solid-phase extraction (SPE) procedure of 0.2 mL of human plasma and analysis was performed on a triple-quadrupole tandem mass spectrometer by multiple reactions monitoring (MRM) mode via electrospray ionization (ESI). The standard calibration curve was linear over the ranges 0.370-95.539 ng/mL for amitriptyline and 0.365-94.374 ng/mL for nortriptyline, expressed by the linear correlation coefficient r², which was better than 0.995 for both. The intra- and inter-day precision and accuracy of the quality control samples were within 10.0%. The recovery was 85.3, 88.4 and 80.7% for amitriptyline, nortriptyline and doxepin respectively. Total run time was 1.2 min only for each sample, which makes it possible to analyze more than 400 samples per day. The method was highly reproducible and gave peaks with excellent chromatography properties. Copyright © 2010 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Rimetz-Planchon, J.; Dhooghe, F.; Schoon, N.; Vanhaecke, F.; Amelynck, C.
2011-04-01
A Flowing Afterglow-Tandem Mass Spectrometer (FA-TMS) was used to investigate the feasibility of selective on-line detection of a series of seven sesquiterpenes (SQTs). These SQTs were chemically ionized by either H3O+ or NO+ reagent ions in the FA, resulting among others in protonated SQT and SQT molecular ions, respectively. These and other Chemical Ionization (CI) product ions were subsequently subjected to dissociation by collisions with Ar atoms in the collision cell of the tandem mass spectrometer. The fragmentation spectra show similarities with mass spectra obtained for these compounds with other instruments such as a Proton Transfer Reaction-Linear Ion Trap (PTR-LIT), a Proton Transfer Reaction-Mass Spectrometer (PTR-MS), a Triple Quadrupole-Mass Spectrometer (QqQ-MS) and a Selected Ion Flow Tube-Mass Spectrometer (SIFT-MS). Fragmentation of protonated SQT is characterized by fragment ions at the same masses but with different intensities for the individual SQT. Distinction of SQTs is based on well-chosen intensity ratios and collision energies. The fragmentation patterns of SQT molecular ions show specific fragment ion tracers at m/z 119, m/z162, m/z 137 and m/z 131 for α-cedrene, δ-neoclovene, isolongifolene and α-humulene, respectively. Consequently, chemical ionization of SQT by NO+, followed by MS/MS of SQT+ seems to open a way for selective quantification of SQTs in mixtures.
Li, Yan; Zhou, Chengxu; Yan, Xiaojun; Zhang, Jinrong; Xu, Jilin
2016-05-01
Phytohormones have attracted wide attention due to their important biological functions. However, their detection is still a challenge because of their complex composition, low abundance and diverse sources. In this study, a novel method of high-performance liquid chromatography with electrospray ionization tandem mass spectrometry was developed and validated for the simultaneous determination of ten phytohormones including indole-3-acetic acid, isopentenyladenine, isopentenyl adenosine, trans-zeatin riboside, zeatin, strigolactones, abscisic acid, salicylic acid, gibberellin A3, and jasmonic acid in Sargassum horneri (S. horneri). The phytohormones were extracted from freeze-dried S. horneri with methanol/water/methanoic acid (15:4:1, v/v/v) analyzed on a Hypersil Gold C18 column and detected by electrospray ionization tandem triple quadrupole mass spectrometry in the multiple reaction monitoring mode. The experimental conditions for the extraction and analysis of phytohormones were optimized and validated in terms of reproducibility, linearity, sensitivity, recovery, accuracy, and stability. Distributions of the phytohormones in the stems, blades, and gas bladder of the S. horneri in drift, fixed, and semi-fixed growing states were investigated for the first time. The observed contents of the phytohormones in S. horneri range from not detected to 5066.67 ng/g (fresh weight). Most phytohormones are distributed mainly in the stems of S. horneri in drift and semi-fixed states. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wei, Zheng; Luo, Jianming; Huang, Yu; Guo, Wenfeng; Zhang, Yali; Guan, Huan; Xu, Changmou; Lu, Jiang
2017-01-01
Polyphenol compositions and concentrations in skins and seeds of five muscadine grapes (cv. “Noble”, “Alachua”, “Carlos”, “Fry”, and “Granny Val”) cultivated in the United States (Tallahassee-Florida, TA-FL) and South China (Nanning-Guangxi, NN-GX and Pu’er-Yunnan, PE-YN) were investigated, using ultra performance liquid chromatography tandem triple quadrupole time-of-flight mass spectrometry (UPLC Triple TOF MS/MS). Fourteen ellagitannins were newly identified in these muscadine grapes. The grapes grown in NN-GX accumulated higher levels of ellagic acid, methyl brevifolin carboxylate, and ellagic acid glucoside in skins, and penta-O-galloyl-glucose in seeds. In PE-YN, more flavonols were detected in skins, and higher contents of flavan-3-ols, ellagic acid, and methyl gallate were identified in seeds. Abundant seed gallic acid and flavonols were found among the grapes grown in TA-FL. Based on principal component analysis (PCA) of 54 evaluation parameters, various cultivars grown in different locations could be grouped together and vice versa for the same cultivar cultivated in different regions. This is the result of the interaction between genotype and environmental conditions, which apparently influences the polyphenol synthesis and accumulation. PMID:28335440
Di Lecce, Giuseppe; Arranz, Sara; Jáuregui, Olga; Tresserra-Rimbau, Anna; Quifer-Rada, Paola; Lamuela-Raventós, Rosa M
2014-02-15
This paper describes for the first time a complete characterisation of the phenolic compounds in different anatomical parts of the Albariño grape. The application of high-performance liquid chromatography coupled with two complementary techniques, hybrid quadrupole time-of-flight and triple-quadrupole mass spectrometry, allowed the phenolic composition of the Albariño grape to be unambiguously identified and quantified. A more complete phenolic profile was obtained by product ion and precursor ion scans, while a neutral loss scan at 152 u enabled a fast screening of procyanidin dimers, trimers and their galloylated derivatives. The compounds were confirmed by accurate mass measurements in QqToF-MS and QqToF-MS/MS modes at high resolution, and good fits were obtained for all investigated ions, with errors ranging from 0.2 to 4.5 mDa. To the best of our knowledge, two flavanol monomer hexosides were detected in the grape berry for the first time. Copyright © 2013 Elsevier Ltd. All rights reserved.
Fox, A
1999-05-28
Bacterial cellular polysaccharides are composed of a variety of sugar monomers. These sugars serve as chemical markers to identify specific species or genera or to determine their physiological status. Some of these markers can also be used for trace detection of bacteria or their constituents in complex clinical or environmental matrices. Analyses are performed, in our hands, employing hydrolysis followed by the alditol acetate derivatization procedure. Substantial improvements have been made to sample preparation including simplification and computer-controlled automation. For characterization of whole cell bacterial hydrolysates, sugars are analyzed by gas chromatography-mass spectrometry (GC-MS). Simple chromatograms are generated using selected ion monitoring (SIM). Using total ion GC-MS, sugars can be readily identified. In more complex clinical and environmental samples, markers for bacteria are present at sufficiently low concentrations that more advanced instrumentation, gas chromatography-tandem mass spectrometry (GC-MS-MS), is preferred for optimal analysis. Using multiple reaction monitoring, MS-MS is used (replacing more conventional SIM) to ignore extraneous chromatographic peaks. Triple quadrupole and ion trap GC-MS-MS instruments have both been used successfully. Absolute chemical identification of sugar markers at trace levels is achieved, using MS-MS, by the product spectrum.
Rood, Johannes J M; van Bussel, Mark T J; Schellens, Jan H M; Beijnen, Jos H; Sparidans, Rolf W
2016-09-15
A method for the quantitative analysis by ultra-performance liquid chromatography-tandem mass spectrometry of the highly selective irreversible covalent inhibitor of EGFR-TK, osimertinib in human plasma was developed and validated, using pazopanib as an internal standard. The validation was performed in a range from 1 to 1000ng/ml, with the lowest level corresponding to the lower limit of quantitation. Gradient elution was performed on a 1.8μm particle trifunctional bonded C18 column by 1% (v/v) formic acid in water, and acetonitrile as mobile phase. The analyte was detected in the selected reaction monitoring mode of a triple quadrupole mass spectrometer after positive ionization with the heated electrospray interface. Within-day precisions ranged from 3.4 to 10.3%, and between-day precisions from 3.8 to 10.4%, accuracies were 95.5-102.8%. Plasma (either lithium heparin or sodium EDTA) pretreatment was performed by salting-out assisted liquid-liquid extraction using acetonitrile and magnesium sulfate. This method was used to analyze the osimertinib blood plasma levels of five adult patients with metastatic T790M mutated non-small cellular lung carcinoma for therapeutic drug monitoring purposes. Copyright © 2016 Elsevier B.V. All rights reserved.
Wang, Yanjuan; Wen, Jing; Zheng, Weihua; Zhao, Longshan; Fu, Xiaohuan; Wang, Zhenzhong; Xiong, Zhili; Li, Famei; Xiao, Wei
2015-01-01
A simple, specific and sensitive ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was established and validated for simultaneous determination of neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid and geniposide in rat plasma using puerarin as an internal standard (IS). Plasma samples were pretreated by a one-step direct protein precipitation procedure with acetonitrile after acidified using as little as 50 μL plasma. Chromatographic separation was performed on an Acquity BEH C18 column (100 × 2.1 mm, 1.7 µm) at a flow rate of 0.2 mL/min by a gradient elution, using 0.2% acetic acid-methanol as mobile phase. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring via electrospray ionization source with negative ion mode. Calibration curves showed good linearity (r > 0.995) over wide concentration ranges. The intra- and inter-day precisions were <15%, and the accuracy was within ±8.0%. The validated method was successfully applied to a pharmacokinetic study of the four bioactive components in rats after intravenous administration of Reduning injection. Copyright © 2014 John Wiley & Sons, Ltd.
Zhang, Dan; Park, Jin-A; Kim, Seong-Kwan; Cho, Sang-Hyun; Cho, Soo-Min; Shim, Jae-Han; Kim, Jin-Suk; Abd El-Aty, A M; Shin, Ho-Chul
2017-06-01
In this study, an analytical method was developed for quantification of residues of the anthelmintic drug phenothiazine (PTZ) in pork muscle using liquid chromatography-tandem mass spectrometry. Muscles were extracted using 0.2% formic acid and 10 mm ammonium formate in acetonitrile, defatted and purified using n-hexane. The drug was well separated on a Waters XBridge™ C 18 analytical column using a binary solvent system consisting of 0.2% formic acid and 10 mm ammonium formate in ultrapure water (A) and acetonitrile (B). Good linearity was achieved over a six-point concentration range in matrix-matched calibration with determination coefficient =0.9846. Fortified pork muscle having concentrations equivalent to and double the limit of quantification (1 ng/g) yielded recovery ranges between 100.82 and 104.03% and relative standard deviations <12%. Samples (n = 5) collected from large markets located in Seoul City tested negative for PTZ residue. In conclusion, 0.2% formic acid and ammonium formate in acetonitrile can effectively extract PTZ from pork muscle without solid-phase extraction, a step normally required for cleanup before analysis and the validated method can be used for routine analysis to ensure the quality of animal products. Copyright © 2016 John Wiley & Sons, Ltd.
Nahar, Limon Khatun; Cordero, Rosa Elena; Nutt, David; Lingford-Hughes, Anne; Turton, Samuel; Durant, Claire; Wilson, Sue; Paterson, Sue
2016-03-01
A highly sensitive and fully validated method was developed for the quantification of baclofen in human plasma. After adjusting the pH of the plasma samples using a phosphate buffer solution (pH 4), baclofen was purified using mixed mode (C8/cation exchange) solid-phase extraction (SPE) cartridges. Endogenous water-soluble compounds and lipids were removed from the cartridges before the samples were eluted and concentrated. The samples were analyzed using triple-quadrupole liquid chromatography-tandem mass spectrometry (LC-MS-MS) with triggered dynamic multiple reaction monitoring mode for simultaneous quantification and confirmation. The assay was linear from 25 to 1,000 ng/mL (r(2) > 0.999; n = 6). Intraday (n = 6) and interday (n = 15) imprecisions (% relative standard deviation) were <5%, and the average recovery was 30%. The limit of detection of the method was 5 ng/mL, and the limit of quantification was 25 ng/mL. Plasma samples from healthy male volunteers (n = 9, median age: 22) given two single oral doses of baclofen (10 and 60 mg) on nonconsecutive days were analyzed to demonstrate method applicability. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Dereziński, Paweł; Klupczyńska, Agnieszka; Sawicki, Wojciech; Kokot, Zenon J
2016-01-01
Creatinine determination in urine is used to estimate the completeness of the 24-h urine collection, compensation for variable diuresis and as a preliminary step in protein profiling in urine. Despite the fact that a wide range of methods of measuring creatinine level in biofluids has been developed, many of them are adversely affected by interfering substances. A new liquid chromatography-tandem mass spectrometry method for creatinine determination in urine has been developed. Chromatographic separation was performed by applying C18 column and a gradient elution. Analyses were carried out on a triple quadrupole mass spectrometer equipped with an electrospray ion source. The developed method was fully validated according to the international guidelines. The quantification range of the method was 5-1500 ng/mL, which corresponds to 1-300 mg/dL in urine. Limit of detection and quantitation were 2 and 5 ng/mL, respectively. Additionally, the comparison of creatinine determination by newly developed method to the colorimetric method was performed. The method enables the determination of creatinine in urine samples with a minimal sample preparation, excellent sensitivity and prominent selectivity. Since mass spectrometry allows to measure a number of compounds simultaneously, a future perspective would be to incorporate the determination of other clinically important compounds excreted in urine.
mzStudio: A Dynamic Digital Canvas for User-Driven Interrogation of Mass Spectrometry Data.
Ficarro, Scott B; Alexander, William M; Marto, Jarrod A
2017-08-01
Although not yet truly 'comprehensive', modern mass spectrometry-based experiments can generate quantitative data for a meaningful fraction of the human proteome. Importantly for large-scale protein expression analysis, robust data pipelines are in place for identification of un-modified peptide sequences and aggregation of these data to protein-level quantification. However, interoperable software tools that enable scientists to computationally explore and document novel hypotheses for peptide sequence, modification status, or fragmentation behavior are not well-developed. Here, we introduce mzStudio, an open-source Python module built on our multiplierz project. This desktop application provides a highly-interactive graphical user interface (GUI) through which scientists can examine and annotate spectral features, re-search existing PSMs to test different modifications or new spectral matching algorithms, share results with colleagues, integrate other domain-specific software tools, and finally create publication-quality graphics. mzStudio leverages our common application programming interface (mzAPI) for access to native data files from multiple instrument platforms, including ion trap, quadrupole time-of-flight, Orbitrap, matrix-assisted laser desorption ionization, and triple quadrupole mass spectrometers and is compatible with several popular search engines including Mascot, Proteome Discoverer, X!Tandem, and Comet. The mzStudio toolkit enables researchers to create a digital provenance of data analytics and other evidence that support specific peptide sequence assignments.
Bergueiro, J; Igarzabal, M; Sandin, J C Suarez; Somacal, H R; Vento, V Thatar; Huck, H; Valda, A A; Repetto, M; Kreiner, A J
2011-12-01
Several ion sources have been developed and an ion source test stand has been mounted for the first stage of a Tandem-Electrostatic-Quadrupole facility For Accelerator-Based Boron Neutron Capture Therapy. A first source, designed, fabricated and tested is a dual chamber, filament driven and magnetically compressed volume plasma proton ion source. A 4 mA beam has been accelerated and transported into the suppressed Faraday cup. Extensive simulations of the sources have been performed using both 2D and 3D self-consistent codes. Copyright © 2011 Elsevier Ltd. All rights reserved.
Kreiner, A J; Castell, W; Di Paolo, H; Baldo, M; Bergueiro, J; Burlon, A A; Cartelli, D; Vento, V Thatar; Kesque, J M; Erhardt, J; Ilardo, J C; Valda, A A; Debray, M E; Somacal, H R; Sandin, J C Suarez; Igarzabal, M; Huck, H; Estrada, L; Repetto, M; Obligado, M; Padulo, J; Minsky, D M; Herrera, M; Gonzalez, S J; Capoulat, M E
2011-12-01
We describe the present status of an ongoing project to develop a Tandem-ElectroStatic-Quadrupole (TESQ) accelerator facility for Accelerator-Based (AB)-BNCT. The project final goal is a machine capable of delivering 30 mA of 2.4 MeV protons to be used in conjunction with a neutron production target based on the (7)Li(p,n)(7)Be reaction. The machine currently being constructed is a folded TESQ with a high-voltage terminal at 0.6 MV. We report here on the progress achieved in a number of different areas. Copyright © 2011 Elsevier Ltd. All rights reserved.
Chen, Jia; Cheng, Xian-Long; Wei, Feng; Zhang, Qian-Qian; Li, Ming-Hua; Ma, Shuang-Cheng
2015-01-01
Simultaneous identification of donkey-hide gelatin and bovine-hide gelatin in deer-horn glue was established by rapid-resolution liquid chromatography-triple quadrupole mass spectrometry. Water containing 1% NH4HCO3 was used for sample dissolution and trypsin was used for hydrolysis of the gelatins. After separation by a SB-C18 reversed-phase analytical column, collagen marker peptides were detected by mass spectrometry in positive electrospray ionization mode with multiple reaction monitoring. The method was specific, precise and reliable, and suitable for detection of adulterants derived from donkey-hide gelatin and bovine-hide gelatin in deer-horn glue. PMID:26504613
Beltrán, Eduardo; Ibáñez, María; Sancho, Juan Vicente; Hernández, Félix
2014-01-01
Sensitive and reliable analytical methodology has been developed for the measurement of patulin in regulated foodstuffs by using ultra-high-performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) with triple quadrupole analyser. Solid samples were extracted with ethyl acetate, while liquid samples were directly injected into the chromatographic system after dilution and filtration without any clean-up step. Chromatographic separation was achieved in less than 4min. Electrospray (ESI) and atmospheric pressure chemical ionisation (APCI) sources were evaluated, in order to assess matrix effects. The use of ESI source caused strong signal suppression in samples; however, matrix effect was negligible using APCI, allowing quantification with calibration standards prepared in solvent. The method was validated in four different apple matrices (juice, fruit, puree and compote) at two concentrations at the low μgkg(-1) level. Average recoveries (n=5) ranged from 71% to 108%, with RSDs lower than 14%. Copyright © 2013 Elsevier Ltd. All rights reserved.
Camino-Sánchez, F J; Bermúdez-Peinado, R; Zafra-Gómez, A; Ruíz-García, J; Vílchez-Quero, J L
2015-02-06
The present paper describes the calibration of selected passive samplers used in the quantitation of trichlorophenol and trichloroanisole in wineries' ambient air, by calculating the corresponding sampling rates. The method is based on passive sampling with sorbent tubes and involves thermal desorption-gas chromatography-triple quadrupole mass spectrometry analysis. Three commercially available sorbents were tested using sampling cartridges with a radial design instead of axial ones. The best results were found for Tenax TA™. Sampling rates (R-values) for the selected sorbents were determined. Passive sampling was also used for accurately determining the amount of compounds present in the air. Adequate correlation coefficients between the mass of the target analytes and exposure time were obtained. The proposed validated method is a useful tool for the early detection of trichloroanisole and its precursor trichlorophenol in wineries' ambient air while avoiding contamination of wine or winery facilities. Copyright © 2015 Elsevier B.V. All rights reserved.
Wu, Chia-Chang
2017-08-15
We propose a simple, rapid analytical method for determination of 89 pesticides in Oolong tea by GC/MS/MS. Samples were extracted via QuEChERS. The limits of detection and quantification range of the 89 pesticides were 1-25μgL -1 and 10-50μgL -1 , respectively. Good separation was attained in less than 36min. A wide linear range of 1-250μgL -1 was observed with r 2 values from 0.9955 to 0.9998. Pesticide-free tea powder spiked at 50 and 100μgL -1 . Recovery ranges of the 86 (50μgL -1 ) and 83 (100μgL -1 ) pesticides were from 60% to 120%. Relative standard deviations were less than 20%. The laboratory proficiency test (FAPAS, 2014) shows satisfactory (|z|<2) z-score values. The proposed monitoring technique rapidly and efficiently screens, multiple pesticides in Oolong tea. Copyright © 2017 Elsevier Ltd. All rights reserved.
Zhang, Jingjing; Liang, Jiabi; Tian, Yuan; Zhang, Zunjian; Chen, Yun
2007-10-15
A rapid, sensitive and selective LC-MS/MS method was developed and validated for the quantification of aniracetam in human plasma using estazolam as internal standard (IS). Following liquid-liquid extraction, the analytes were separated using a mobile phase of methanol-water (60:40, v/v) on a reverse phase C18 column and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode using the respective [M+H]+ ions, m/z 220-->135 for aniracetam and m/z 295-->205 for the IS. The assay exhibited a linear dynamic range of 0.2-100 ng/mL for aniracetam in human plasma. The lower limit of quantification (LLOQ) was 0.2 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated LC-MS/MS method has been successfully applied to study the pharmacokinetics of aniracetam in healthy male Chinese volunteers.
Dinh, Quoc Tuc; Alliot, Fabrice; Moreau-Guigon, Elodie; Eurin, Joëlle; Chevreuil, Marc; Labadie, Pierre
2011-09-15
This study presents the development of an automated on-line solid phase extraction (SPE)-liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of 23 antibiotics in environmental water samples. After optimisation of LC-MS/MS conditions, SPE parameters such as sorbent type, sample pH or sample volume were optimised. Antibiotic recoveries ranged from 64% to 98% and compared favourably with those achieved using off-line SPE. Limits of detection were in the range 0.5-13.7 ng L(-1). This on-line SPE-LC-MS/MS procedure was applied to the analysis of water samples taken in three rivers within the Seine River basin, near Paris (France). The obtained results revealed the occurrence of 12 antibiotics, including tylosin, erythromycin, tetracycline, amoxicillin, trimethoprim, sulfamethoxazole, oxolinic acid, flumequine, norfloxacin, ciprofloxacin, ofloxacin, and vancomycin (2-1435 ng L(-1)). Copyright © 2011 Elsevier B.V. All rights reserved.
Li, Jiaxin; Wang, Pengsi; Shi, Shangmei; Xue, Jian
2018-04-29
Due to the widespread use of pesticides, human exposure to pesticides is possible and can potentially cause adverse impacts on public health. We measured 137 pesticides including organophosphorus, organochlorine, pyrethroid and carbamate pesticides together with various herbicides in 100 human blood samples collected from the general population in Beijing. The samples were analysed by triple quadrupole tandem gas chromatography-mass spectrometry. In total, 24 organochlorine pesticides, 5 pyrethroid pesticides and 6 organophosphorus pesticides were detected. The detection rates of HCB, α-HCH, β-HCH, γ-HCH, p,p'-DDE and quintozene were 99, 96, 74, 72, 96 and 95%, respectively. No statistically significant gender difference in the blood concentrations of the pesticides was found. Consistent with the trend of the increasing β-HCH, p,p'-DDE and quintozene concentrations with age, a strong positive correlation between the age and concentrations of β-BHC, p,p'-DDE and quintozene was observed.
NASA Astrophysics Data System (ADS)
Manicke, Nicholas E.; Belford, Michael
2015-05-01
One limitation in the growing field of ambient or direct analysis methods is reduced selectivity caused by the elimination of chromatographic separations prior to mass spectrometric analysis. We explored the use of high-field asymmetric waveform ion mobility spectrometry (FAIMS), an ambient pressure ion mobility technique, to separate the closely related opiate isomers of morphine, hydromorphone, and norcodeine. These isomers cannot be distinguished by tandem mass spectrometry. Separation prior to MS analysis is, therefore, required to distinguish these compounds, which are important in clinical chemistry and toxicology. FAIMS was coupled to a triple quadrupole mass spectrometer, and ionization was performed using either a pneumatically assisted heated electrospray ionization source (H-ESI) or paper spray, a direct analysis method that has been applied to the direct analysis of dried blood spots and other complex samples. We found that FAIMS was capable of separating the three opiate structural isomers using both H-ESI and paper spray as the ionization source.
Herrero, P; Borrull, F; Pocurull, E; Marcé, R M
2012-11-09
A fast chromatographic method has been developed that takes less than 5 min per run to determine five polyether ionophores with a novel amide polar-embedded reversed-phase column coupled to a triple quadrupole mass spectrometer. A comparison between Oasis HLB and Oasis MAX sorbents for the solid-phase extraction was done. Oasis HLB sorbent gave recoveries close to 90% and the repeatability (%RSD, 25-100 ng/L, n=3) of the method was less than 7% for all compounds in all matrices. The presence of polyether ionophores in environmental waters such as river water and sewage was investigated. Monensin and narasin were frequently determined in influent and effluent sewage at concentrations from 10 ng/L to 47 ng/L in influents and from 6 ng/L to 34 ng/L in effluents. In river waters, polyether ionophores were not detected in any sample. Copyright © 2012 Elsevier B.V. All rights reserved.
Hori, Katsuhito; Matsubara, Atsuki; Uchikata, Takato; Tsumura, Kazunobu; Fukusaki, Eiichiro; Bamba, Takeshi
2012-08-10
We have established a high-throughput and sensitive analytical method based on supercritical fluid chromatography (SFC) coupled with triple quadrupole mass spectrometry (QqQ MS) for 3-monochloropropane-1,2-diol (3-MCPD) fatty acid esters in edible oils. All analytes were successfully separated within 9 min without sample purification. The system was precise and sensitive, with a limit of detection less than 0.063 mg/kg. The recovery rate of 3-MCPD fatty acid esters spiked into oil samples was in the range of 62.68-115.23%. Furthermore, several edible oils were tested for analyzing 3-MCPD fatty acid ester profiles. This is the first report on the analysis of 3-MCPD fatty acid esters by SFC/QqQ MS. The developed method will be a powerful tool for investigating 3-MCPD fatty acid esters in edible oils. Copyright © 2012 Elsevier B.V. All rights reserved.
Zhang, Hui; Bayen, Stéphane; Kelly, Barry C
2015-08-01
A gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS) based method was developed for determination of 86 hydrophobic organic compounds in seawater. Solid-phase extraction (SPE) was employed for sequestration of target analytes in the dissolved phase. Ultrasound assisted extraction (UAE) and florisil chromatography were utilized for determination of concentrations in suspended sediments (particulate phase). The target compounds included multi-class hydrophobic contaminants with a wide range of physical-chemical properties. This list includes several polycyclic and nitro-aromatic musks, brominated and chlorinated flame retardants, methyl triclosan, chlorobenzenes, organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs). Spiked MilliQ water and seawater samples were used to evaluate the method performance. Analyte recoveries were generally good, with the exception of some of the more volatile target analytes (chlorobenzenes and bromobenzenes). The method is very sensitive, with method detection limits typically in the low parts per quadrillion (ppq) range. Analysis of 51 field-collected seawater samples (dissolved and particulate-bound phases) from four distinct coastal sites around Singapore showed trace detection of several polychlorinated biphenyl congeners and other legacy POPs, as well as several current-use emerging organic contaminants (EOCs). Polycyclic and nitro-aromatic musks, bromobenzenes, dechlorane plus isomers (syn-DP, anti-DP) and methyl triclosan were frequently detected at appreciable levels (2-20,000pgL(-1)). The observed concentrations of the monitored contaminants in Singapore's marine environment were generally comparable to previously reported levels in other coastal marine systems. To our knowledge, these are the first measurements of these emerging contaminants of concern in Singapore or Southeast Asia. The developed method may prove beneficial for future environmental monitoring of hydrophobic organic contaminants in marine environments. Further, the study provides novel information regarding several potentially hazardous contaminants of concern in Singapore's marine environment, which will aid future risk assessment initiatives. Copyright © 2015 Elsevier B.V. All rights reserved.
Mata, Ana Teresa; Jorge, Tiago Filipe; Ferreira, João; do Rosário Bronze, Maria; Branco, Diana; Fevereiro, Pedro; Araújo, Susana; António, Carla
2016-12-16
Trehalose-6-phosphate (T6P) is an important signaling metabolite involved in plant growth control that inhibits the sucrose nonfermenting-1-related protein kinase 1 (SnRK1), a key regulator of energy and carbon metabolism in plants. The quantification of T6P in plant tissues is fundamental to improve our understanding of sugar signaling and the links between plant growth and development in response to stress conditions. However, the almost undetectable levels of T6P together with the complex plant matrix and the presence of T6P isomers such as sucrose-6-phosphate (S6P), makes the detection of this metabolite challenging. This work describes the development and validation of a hydrophilic interaction chromatography (HILIC) method for the on-line coupling with negative ion electrospray (ESI) triple quadrupole tandem mass spectrometry (MS/MS) in the highly sensitive and selective multiple reaction monitoring (MRM) mode for the target analysis of metabolic intermediates of the biosynthesis of trehalose, including glucose-6-phosphate (G6P), uridine 5-diphospho-glucose (UDPG), T6P (and its isomer S6P). Enhanced signal in the MRM mode and improved chromatographic separation for each compound were obtained using piperidine and methylphosphonic acid as additives in the HILIC mobile phase. The optimized HILIC-ESI-QqQ-MS/MS method increases the range of sensitive analytical methodologies for the quantification of key low-abundant metabolites, and was applied to quantify the fluctuations of S6P, T6P and G6P in Medicago truncatula plants in response to environmental stress. The levels of S6P, T6P, and G6P in M. truncatula plant tissues (roots and leaves) exposed to a water deficit and recovery treatment, ranged from 30 to 150pmolg -1 FW, 16-120pmolg -1 FW, and 330-1690pmolg -1 FW, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.
Cristoni, Simone; Dusi, Guglielmo; Brambilla, Paolo; Albini, Adriana; Conti, Matteo; Brambilla, Maura; Bruno, Antonino; Di Gaudio, Francesca; Ferlin, Luca; Tazzari, Valeria; Mengozzi, Silvia; Barera, Simone; Sialer, Carlos; Trenti, Tommaso; Cantu, Marco; Rossi Bernardi, Luigi; Noonan, Douglas M
2017-01-01
Electrospray Ionization and collision induced dissociation tandem mass spectrometry are usually employed to obtain compound identification through a mass spectra match. Different algorithms have been developed for this purpose (for example the nist match algorithm). These approaches compare the tandem mass spectra of the unknown analyte with the tandem mass spectra spectra of known compounds inserted in a database. The compounds are usually identified on the basis of spectral match value associated with a probability of recognition. However, this approach is not usually applied to multiple reaction monitoring transition spectra achieved by means of triple quadrupole apparatus, mainly due to the lack of a transition spectra database. The Surface Activated Chemical Ionization-Electrospray-NIST Bayesian model database search (SANIST) platform has been recently developed for new potential metabolite biomarker discovery, to confirm their identity and to use them for clinical and diagnostic applications. Here, we present an improved version of the SANIST platform that extends its application to forensic, pharmaceutical, and food analysis studies, where the compound identification rules are strict. The European Union (EU) has set directives for compound identification (EU directive 2002/657/EC). We have applied the SANIST method to identification of 11-nor-9-carboxytetrahydro-cannabinol in urine samples (an example of a forensic application), circulating levels of the immunosuppressive drug tacrolimus in blood (an example of a pharmaceutical application) and glyphosate in fruit juice (an example of a food analysis application) that meet the EU directive requirements. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Sala, Federica; Albares, Pablo; Colovic, Milena; Persiani, Stefano; Rovati, Lucio C
2014-01-15
To investigate the pharmacokinetics of silibinin and silibinin hemisuccinate in human plasma, two high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) methods were developed and validated. The methods require a small volume of sample (100μL), and the recovery of the analytes was complete with a good reproducibility (CV% 1.7-9.5), after a simple protein precipitation. Naringenin was used as internal standard. The chromatographic methods provided a good separation of diastereoisomers A and B of both silibinin and silibinin hemisuccinate onto a Chromolith Performance RP18e 100mm×3mm column, with a resolution of peaks from plasma matrix in less than 6min. The methods precision values expressed as CV% were always ≤6.2% and the accuracy was always well within the acceptable 15% range. Quantification was performed on a triple-quadrupole tandem mass spectrometer by Selected Reaction Monitoring (SRM) mode, in a negative ion mode, via electrospray ionization (ESI). The lower limit of quantitation was set at 5.0ng/mL (silibinin) and 25.0ng/mL (silibinin hemisuccinate), and the linearity was validated up to 1000.0 and 12,500.0ng/mL, for silibinin and silibinin hemisuccinate, respectively, with correlation coefficients (R(2)) of 0.991 or better. The methods were suitable for pharmacokinetic studies and were successfully applied to human plasma samples from subjects treated intravenously with Legalon(®) SIL at the dose of 20mg/kg, expressed as silibinin. Copyright © 2013 Elsevier B.V. All rights reserved.
Wang, Fang-Xu; Yuan, Jian-Chao; Kang, Li-Ping; Pang, Xu; Yan, Ren-Yi; Zhao, Yang; Zhang, Jie; Sun, Xin-Guang; Ma, Bai-Ping
2016-09-10
An ultra high-performance liquid chromatography quadrupole time-of-flight tandem mass spectrometry approach coupled with multivariate statistical analysis was established and applied to rapidly distinguish the chemical differences between fibrous root and rhizome of Anemarrhena asphodeloides. The datasets of tR-m/z pairs, ion intensity and sample code were processed by principal component analysis and orthogonal partial least squares discriminant analysis. Chemical markers could be identified based on their exact mass data, fragmentation characteristics, and retention times. And the new compounds among chemical markers could be isolated rapidly guided by the ultra high-performance liquid chromatography quadrupole time-of-flight tandem mass spectrometry and their definitive structures would be further elucidated by NMR spectra. Using this approach, twenty-four markers were identified on line including nine new saponins and five new steroidal saponins of them were obtained in pure form. The study validated this proposed approach as a suitable method for identification of the chemical differences between various medicinal parts in order to expand medicinal parts and increase the utilization rate of resources. Copyright © 2016 Elsevier B.V. All rights reserved.
Hellmuth, Christian; Weber, Martina; Koletzko, Berthold; Peissner, Wolfgang
2012-02-07
Despite their central importance for lipid metabolism, straightforward quantitative methods for determination of nonesterified fatty acid (NEFA) species are still missing. The protocol presented here provides unbiased quantitation of plasma NEFA species by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Simple deproteination of plasma in organic solvent solution yields high accuracy, including both the unbound and initially protein-bound fractions, while avoiding interferences from hydrolysis of esterified fatty acids from other lipid classes. Sample preparation is fast and nonexpensive, hence well suited for automation and high-throughput applications. Separation of isotopologic NEFA is achieved using ultrahigh-performance liquid chromatography (UPLC) coupled to triple quadrupole LC-MS/MS detection. In combination with automated liquid handling, total assay time per sample is less than 15 min. The analytical spectrum extends beyond readily available NEFA standard compounds by a regression model predicting all the relevant analytical parameters (retention time, ion path settings, and response factor) of NEFA species based on chain length and number of double bonds. Detection of 50 NEFA species and accurate quantification of 36 NEFA species in human plasma is described, the highest numbers ever reported for a LC-MS application. Accuracy and precision are within widely accepted limits. The use of qualifier ions supports unequivocal analyte verification. © 2012 American Chemical Society
Svan, Alfred; Hedeland, Mikael; Arvidsson, Torbjörn; Jasper, Justin T; Sedlak, David L; Pettersson, Curt E
2015-08-28
A method for enantiomeric separation of the three β-blocking agents atenolol, metoprolol, propranolol and the zwitterionic metoprolol acid, a major metabolite of both metoprolol and in environmental matrices also atenolol, has been developed. By use of supercritical fluid chromatography and the polysaccharide-based Chiralpak(®) IB-3, all four compounds were simultaneously enantiomerically separated (Rs>1.5) within 8min. Detection was performed using tandem mass spectrometry, and to avoid isobaric interference between the co-eluting metoprolol and metoprolol acid, the achiral column Acquity(®) UPC(2) BEH 2-EP was attached ahead of to the chiral column. Carbon dioxide with 18% methanol containing 0.5% (v/v) of the additives trifluoroacetic acid and ammonia in a 2:1 molar ratio were used as mobile phase. A post column make-up flow (0.3mL/min) of methanol containing 0.1% (v/v) formic acid was used to enhance the positive electrospray ionization. Detection was carried out using a triple quadrupole mass spectrometer operating in the selected reaction monitoring mode, using one transition per analyte and internal standard. The method was successfully applied for monitoring the enantiomeric fraction change over time in a laboratory scale wetland degradation study. It showed good precision, recovery, sensitivity and low effect of the sample matrix. Copyright © 2015. Published by Elsevier B.V.
Herbrink, M; de Vries, N; Rosing, H; Huitema, A D R; Nuijen, B; Schellens, J H M; Beijnen, J H
2018-04-01
To support therapeutic drug monitoring of patients with cancer, a fast and accurate method for simultaneous quantification of the registered anticancer drugs afatinib, axitinib, ceritinib, crizotinib, dabrafenib, enzalutamide, regorafenib and trametinib in human plasma using liquid chromatography tandem mass spectrometry was developed and validated. Human plasma samples were collected from treated patients and stored at -20°C. Analytes and internal standards (stable isotopically labeled analytes) were extracted with acetonitrile. An equal amount of 10 mm NH 4 CO 3 was added to the supernatant to yield the final extract. A 2 μL aliquot of this extract was injected onto a C 18 -column, gradient elution was applied and triple-quadrupole mass spectrometry in positive-ion mode was used for detection. All results were within the acceptance criteria of the latest US Food and Drug Administration guidance and European Medicines Agency guidelines on method validation, except for the carry-over of ceritinib and crizotinib. These were corrected for by the injection order of samples. Additional stability tests were carried out for axitinib and dabrafenib in relation to their reported photostability. In conclusion, the described method to simultaneously quantify the eight selected anticancer drugs in human plasma was successfully validated and applied for therapeutic drug monitoring in cancer patients treated with these drugs. Copyright © 2017 John Wiley & Sons, Ltd.
Zhang, Xinxin; Li, Jing; Ito, Yoichiro; Sun, Wenji
2014-01-01
A simple, reliable and sensitive high-performance liquid chromatography tandem mass spectrometry method (HPLC-MS/MS) was established for simultaneous analyses of the following 5 steroid saponins in rat plasma after the single dose administration of total steroid saponins extracted from the rhizome of Dioscorea zingiberensis C.H.Wright for the first time. Protodioscin, huangjiangsu A, zingiberensis new saponin, dioscin, and gracillin were quantified using ginsenoside Rb1 as the internal standard (IS). The plasma samples were pretreated by a single step acetonitrile-mediated protein precipitation. The chromatographic separation was performed on an Inersil ODS-3 C18 column (250 mm × 4.6 mm, 5 μm) with the mobile phase composed of acetonitrile and water containing 0.1% formic acid under a gradient elution mode at 0.2 mL min−1 using a microsplit after the eluent from the HPLC apparatus. The quantification was accomplished on a triple quadrupole tandem mass spectrometer using the multiple reaction monitoring (MRM) in the positive ionization mode. The above five analytes were stable under sample storage and preparation conditions applied in the present study. The linearity, precision, accuracy, and recoveries of the analysis confirmed the requirements for quality-control purposes. After validation, this proposed method was successfully adopted to investigate the pharmacokinetic parameters of these five analytes. PMID:25201262
Ding, Ying; Huang, Kai; Chen, Lan; Yang, Jie; Xu, Wen-Yan; Xu, Xue-Jiao; Duan, Ru; Zhang, Jing; He, Qing
2014-03-01
A sensitive and accurate HPLC-MS/MS method was developed for the simultaneous determination of dextromethorphan, dextrorphan and chlorphenamine in human plasma. Three analytes were extracted from plasma by liquid-liquid extraction using ethyl acetate and separated on a Kromasil 60-5CN column (3 µm, 2.1 × 150 mm) with mobile phase of acetonitrile-water (containing 0.1% formic acid; 50:50, v/v) at a flow rate of 0.2 mL/min. Quantification was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode using positive electrospray ionization. The calibration curve was linear over the range of 0.01-5 ng/mL for dextromethorphan, 0.02-5 ng/mL for dextrorphan and 0.025-20 ng/mL for chlorphenamine. The lower limits of quantification for dextromethorphan, dextrorphan and chlorphenamine were 0.01, 0.02 and 0.025 ng/mL, respectively. The intra- and inter-day precisions were within 11% and accuracies were in the range of 92.9-102.5%. All analytes were proved to be stable during sample storage, preparation and analytic procedures. This method was first applied to the pharmacokinetic study in healthy Chinese volunteers after a single oral dose of the formulation containing dextromethorphan hydrobromide (18 mg) and chlorpheniramine malaeate (8 mg). Copyright © 2013 John Wiley & Sons, Ltd.
Pang, Hanqing; Wang, Jun; Tang, Yuping; Xu, Huiqin; Wu, Liang; Jin, Yi; Zhu, Zhenhua; Guo, Sheng; Shi, Xuqin; Huang, Shengliang; Sun, Dazheng; Duan, Jin-Ao
2016-11-01
Xin-Sheng-Hua granule, a representative formula for postpartum hemorrhage, has been used clinically to treat postpartum diseases. Its main bioactive components comprise aromatic acids, phthalides, alkaloids, flavonoids, and gingerols among others. To investigate the changes in main bioactive constituents in its seven single herbs before and after compatibility, a rapid, simple, and sensitive method was developed for comparative analysis of 27 main bioactive components by using ultrahigh-performance liquid chromatography with triple quadrupole electrospray tandem mass spectrometry for the first time. The sufficient separation of 27 target constituents was achieved on a Thermo Scientific Hypersil GOLD column (100 mm × 3 mm, 1.9 μm) within 20 min under the optimized chromatographic conditions. Compared with the theoretical content, the observed content of each analyte showed remarkable differences in Xin-Sheng-Hua granule except thymine, p-coumaric acid, senkyunolide I, senkyunolide H, and ligustilide; the total contents of 27 components increased significantly, and the content variation degrees for the different components were gingerols > flavonoids > aromatic acids > alkaloids > phthalides. The results could provide a good reference for the quality control of Xin-Sheng-Hua granule and might be helpful to interpret the drug interactions based on variation of bioactive components in formulae. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hösl, Julian; Gessner, André; El-Najjar, Nahed
2018-05-12
A simple and precise ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed for the simultaneous analysis of five anti-infective agents used to treat severe infections [three antibiotics (daptomycin, moxifloxacin, ciprofloxacin) and two antifungals (isavuconazole, caspofungin)] in human plasma. Sample preparation was based on protein precipitation with ice cold methanol. All five agents were analyzed with the corresponding isotopically labeled internal standards. All analytes were detected in multiple reactions monitoring (MRM) using API 4000 triple-quadrupole mass spectrometer with electrospray (ESI) source operating in positive mode. The calibration curves were linear over the selected ranges (r > 0.99). The method is precise and accurate with a total run time of 5.5 min. Accuracy of all target analytes ranged between 95.9-116.6%, measured with an imprecision of less than 10.8%. The lower limit of quantification was 1.25 mg/L for caspofungin, 0.3125 mg/L for isavuconazole, 3.125 mg/L for daptomycin, 0.075 mg/L for ciprofloxacin, and 0.1875 mg/L for moxifloxacin. The successful application of the method in patient samples proved its suitability for the medical surveillance of antimicrobial therapy in intensive care units as well as to other pharmacokinetic studies. Copyright © 2018. Published by Elsevier B.V.
Castilhos, Tamara S; Barreto, Fabiano; Meneghini, Leonardo; Bergold, Ana Maria
2016-07-01
A reliable and simple method for the detection and quantification of residues of 14 non-steroidal anti-inflammatory drugs and a metamizole metabolite in swine muscle was developed using liquid chromatography-electrospray ionisation-tandem mass spectrometry (LC-ESI-MS/MS). The samples were extracted with acetonitrile (ACN) in solid-liquid extraction followed by a low-temperature partitioning (LLE-LTP) process at -20 ± 2°C. After evaporation to dryness, the residue was reconstituted with hexane and a mixture of water:acetonitrile (1:1). LC separation was achieved on a reversed-phase (RP18) column with gradient elution using water (phase A) and ACN (phase B) both containing 1 mmol l(-)(1) ammonium acetate (NH4COO) with 0.025% acetic acid. Analysis was carried out on a triple-quadrupole tandem mass spectrometer (LC-MS/MS) in multiple reaction monitoring mode using an electrospray interface in negative and positive mode in a single run. Method validation was performed according to the criteria of Commission Decision No. 2002/657/EC. The matrix effect and linearity were evaluated. Decision limit (CCα), detection capability (CCβ), accuracy and repeatability of the method are also reported. The proposed method proved to be simple, easy and adequate for high-throughput analysis and was applied to routine analysis by the Brazilian Ministry of Agriculture, Livestock and Food Supply.
Socas-Rodríguez, Bárbara; González-Sálamo, Javier; Herrera-Herrera, Antonio V; Santana-Mayor, Álvaro; Hernández-Borges, Javier
2018-03-09
In this work, a new method has been developed for the determination of 14 phthalic acid esters (i.e., benzylbutyl phthalate (BBP), bis-2-n-butoxyethyl phthalate (DBEP), dibutyl phthalate (DBP), dicyclohexyl phthalate (DCHP), bis-2-ethoxyethyl phthalate (DEEP), diethyl phthalate (DEP), diisodecyl phthalate (DIDP), diisononyl phthalate (DINP), bis-isopentyl phthalate (DIPP), bis (2-methoxyethyl) phthalate (DMEP), dimethyl phthalate (DMP), di-n-octyl phthalate (DNOP), bis-n-pentyl phthalate (DNPP), dipropyl phthalate (DPP)) and one adipate (bis (2-ethylhexyl) adipate (DEHA)) in different baby foods. Separation was carried out by gas chromatography triple quadrupole tandem mass spectrometry while the previous extraction of the samples was carried out using the QuEChERS method. The methodology was validated for four baby food samples (two fruit compotes of different compositions and two meat and fish purees with vegetables) using dibutyl phthalate-3,4,5,6-d 4 (DBP-d 4 ) as internal standard. Determination coefficients (R 2 ) of matrix-matched calibration curves were above 0.9922 in all cases while relative recovery values ranged between 70 and 120%, with relative standard deviation values below 19%. The limits of quantification of the method ranged between 0.03 and 1.11 μg/kg. Finally, the analysis of commercially available samples was carried out finding the presence of BBP, DEHA, DEP, DIDP, and DPP in some of the studied samples.
Lai, Chi-Kong; Poon, Wing-Tat; Chan, Yan-Wo
2006-09-01
Poisoning from aconite occurs worldwide as a result of misuse of the potent plant. Laboratory investigation into suspected intoxication cases is challenging because the content of toxic aconitum alkaloids varies depending on the plant source, market processing, dosing protocol, hydrolytic degradation, and metabolic transformation. Using a triple-quadrupole tandem mass spectrometer, a group screening method was developed based on the mass-fragmentographic scheme of common aconitum alkaloids. The precursor-ion scans of m/z 105 and 135 permitted selective profiling of 14-O-benzoyl-norditerpenoids and the 14-O-anisoyl-norditerpenoids, respectively. Gradient reversed-phase liquid chromatography minimized coelution of isobaric compounds. The screening protocol was applied to a clinical investigation of suspected herbal poisoning. In total, 15 urine samples were thus screened positive for aconitum alkaloid over 5 years. The diagnoses of aconite poisoning in 11 patients were firmly established based on the known prescription history and the positive urine finding. In four patients, without aconitum herbs being listed in the herbal prescriptions, contamination of the herbal remedies by aconite was suspected to be the hidden cause of their acute poisoning. Yunaconitne, a highly toxic aconitum alkaloid, was thus identified in human urine for the first time. The group screening method of aconitum alkaloids in urine is an important diagnostic aid for acute poisoning by aconites of an unclear origin.
Determination and pharmacokinetic study of pirfenidone in rat plasma by UPLC-MS/MS.
Sun, Wei; Jiang, Zhe-li; Zhou, Lei; Chen, Rui-min; Wang, Zhe; Li, Wan-shu; Jiang, Shuo-min; Hu, Guo-xin; Chen, Rui-jie
2015-02-15
A rapid, sensitive and selective ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was developed and validated for the determination and pharmacokinetic investigation of pirfenidone in rat plasma. Sample preparation was accomplished through a simple one-step deproteinization procedure with 0.2 mL of acetonitrile to a 0.1 mL plasma sample. Plasma samples were separated by UPLC on an Acquity UPLC BEH C18 column using a mobile phase consisting of acetonitrile-0.1% formic acid in water with gradient elution. The total run time was 3.0 min and the elution of pirfenidone was at 1.39 min. The detection was performed on a triple quadrupole tandem mass spectrometer in the multiple reaction-monitoring (MRM) mode using the respective transitions m/z 186.2→92.1 for pirfenidone and m/z 237.1→194.2 for carbamazepine (IS), respectively. The calibration curve was linear over the range of 5-2000 ng/mL with a lower limit of quantitation (LLOQ) of 5 ng/mL. Mean recovery of pirfenidone in plasma was in the range of 80.4-84.3%. Intra-day and inter-day precision were both <12.1%. This method was successfully applied in pharmacokinetic study after oral administration of 10.0mg/kg pirfenidone in rats. Copyright © 2015 Elsevier B.V. All rights reserved.
Kinoshita, Kohnosuke; Jingu, Shigeji; Yamaguchi, Jun-ichi
2013-01-15
A bioanalytical method for determining endogenous d-serine levels in the mouse brain using a surrogate analyte and liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. [2,3,3-(2)H]D-serine and [(15)N]D-serine were used as a surrogate analyte and an internal standard, respectively. The surrogate analyte was spiked into brain homogenate to yield calibration standards and quality control (QC) samples. Both endogenous and surrogate analytes were extracted using protein precipitation followed by solid phase extraction. Enantiomeric separation was achieved on a chiral crown ether column with an analysis time of only 6 min without any derivatization. The column eluent was introduced into an electrospray interface of a triple-quadrupole mass spectrometer. The calibration range was 1.00 to 300 nmol/g, and the method showed acceptable accuracy and precision at all QC concentration levels from a validation point of view. In addition, the brain d-serine levels of normal mice determined using this method were the same as those obtained by a standard addition method, which is time-consuming but is often used for the accurate measurement of endogenous substances. Thus, this surrogate analyte method should be applicable to the measurement of d-serine levels as a potential biomarker for monitoring certain effects of drug candidates on the central nervous system. Copyright © 2012 Elsevier Inc. All rights reserved.
Guo, Changchuan; Jiang, Yan; Li, Li; Hong, Lan; Wang, Yuqing; Shen, Qian; Lou, Yan; Hu, Haihong; Zhou, Hui; Yu, Lushan; Jiang, Huidi; Zeng, Su
2013-02-23
The herbal ingredients of isocorydine and protopine were isolated from Dactylicapnos scandens. This study was aimed at developing a liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method to quantify isocorydine and protopine in rat plasma and tissues for pharmacokinetic, tissue distribution and excretion studies. Biological samples were processed with ethyl acetate extraction, and corydaline was chosen as the internal standard (IS). The analytes were separated by a C(18) column and detected with a triple quadrupole mass spectrometer using positive ion ESI in the multiple reaction monitoring (MRM) mode. The MS/MS ion transitions monitored were m/z 342.0→278.9 for isocorydine, 354.1→188.0 for protopine and 370.0→192.0 for IS, respectively. Excellent linearity was observed over the concentration range between 10 and 3000 ng/mL for isocorydine and 10-300 ng/mL for protopine. The lower limit of quantification (LLOQ) was 10 ng/mL for both isocorydine and protopine. This novel method was rapid, accurate, high sensitive and high selective. It was successfully applied to the pharmacokinetic, tissue distribution and excretion studies of D. scandens. These preclinical data of D. scandens would be useful for the clinical reference. Copyright © 2012 Elsevier B.V. All rights reserved.
Liu, Xiaoying; Liu, Qian; Wang, Dongmei; Wang, Xueya; Zhang, Peng; Xu, Haiyan; Zhao, Hui; Zhao, Huaiqing
2010-05-01
A highly sensitive and selective LC-MS/MS method was developed and validated for the determination of dauricine in human plasma, using protopine as internal standard (IS). The analyte and IS were extracted by liquid-liquid extraction and analyzed by LC-MS/MS. Chromatographic separation was performed on Agilent TC-C(18) column with a mobile phase of methanol-water-glacial acetic acid (60:40:0.8, v/v/v) at a flow rate of 0.7 mL/min. Detection was performed on a triple quadrupole tandem mass spectrum by multiple reaction monitoring (MRM) mode using the electrospray ionization technique in positive mode. The method was linear over the concentration range of 1-200 ng/mL. The lower limit of quantification (LLOQ) was 1 ng/mL in human plasma with acceptable precision and accuracy. The intra- and inter-day precision was less than 5.9% determined from quality control (QC) samples at concentrations of 2.0, 20.0 and 160 ng/mL, and the accuracy was within +/-9.9%. This method was successfully applied for the evaluation of pharmacokinetics of dauricine after oral doses of 100, 300 and 600 mg phenolic alkaloids of menispermum dauricum tablet (PAMDT) to 12 Chinese healthy volunteers. 2010 Elsevier B.V. All rights reserved.
El-Bagary, Ramzia; Hashem, Hanaa; Fouad, Marwa; Tarek, Sally
2016-09-01
A sensitive, rapid and simple liquid chromatographic-electrospray ionization tandem mass spectrometric (LC-ESI-MS-MS) method was developed for the quantitative determination of vilazodone in human plasma and for the study of the pharmacokinetic behavior of vilazodone in healthy Egyptian volunteers. With escitalopram as internal standard (IS), liquid-liquid extraction was used for the purification and preconcentration of analytes from human plasma matrix using diethyl ether. The separation was performed on an Acquity UPLC BEH shield RP C18 column (1.7 µm, 2.1 × 150 mm). Isocratic elution was applied using methanol-0.2% formic acid (90:10, v/v). Detection was performed on a triple-quadrupole tandem mass spectrometer with multiple reaction monitoring mode via an electrospray ionization source at m/z 442.21 → 155.23 for vilazodone and m/z 325.14 → 109.2 for escitalopram. Linear calibration curves were obtained over the range of 1-200 ng/mL with the lower limit of quantification at 1 ng/mL. The intra- and inter-day precision showed relative standard deviation ≤3.3%. The total run time was 1.5 min. This method was successfully applied for clinical pharmacokinetic investigation, and a preliminary metabolic study was also carried out. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Lee, Ji Hyun; Park, Han Na; Choi, Ji Yeon; Kim, Nam Sook; Park, Hyung-Joon; Park, Seong Soo; Baek, Sun Young
2017-12-01
Adulterated products are continuously detected in society and cause problems. In this study, we developed and validated a method for determining synthetic sedative-hypnotics and sleep inducers, including barbital, benzodiazepam, zolpidem, and first-generation antihistamines, in adulterated products using Quadrupole-Orbitrap mass spectrometry and ultrahigh performance liquid chromatography with tandem mass spectrometry. In Quadrupole-Orbitrap mass spectrometry analysis, target compounds were confirmed using a combination of retention time, mass tolerance, mass accuracy, and fragment ions. For quantification, several validation parameters were employed using ultrahigh performance liquid chromatography with tandem mass spectrometry. The limit of detection and limit of quantitation was 0.05-53 and 0.17-177 ng/mL, respectively. The correlation coefficient for linearity was more than 0.995. The intra- and interassay accuracies were 86-110 and 84-111%, respectively. Their precision values were evaluated as within 4.0 (intraday) and 10.7% (interday). Mean recoveries of target compounds in adulterated products ranged from 85 to 116%. The relative standard deviation of stability was less than 10.7% at 4°C for 48 h. The 144 adulterated products obtained over 3 years (2014-2016) from online and in-person vendors were tested using established methods. After rapidly screening with Quadrupole-Orbitrap mass spectrometry, the detected samples were quantified using ultrahigh performance liquid chromatography with tandem mass spectrometry. Two of them were adulterated with phenobarbital. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Single particle analysis of TiO2 in candy products using triple quadrupole ICP-MS.
Candás-Zapico, S; Kutscher, D J; Montes-Bayón, M; Bettmer, J
2018-04-01
Titanium dioxide (TiO 2 ) belongs to the materials that have gained great importance in many applications. In its particulate form (micro- or nanoparticles), it has entered a huge number of consumer products and food-grade TiO 2 , better known as E171 within the European Union, represents an important food additive. Thus, there is an increasing need for analytical methods able to detect and quantify such particles. In this regard, inductively coupled-mass spectrometry (ICP-MS), in particular single particle ICP-MS (spICP-MS), has gained importance due to its simplicity and ease of use. Nevertheless, the number of applications for Ti nanoparticles is rather limited. In this study, we have applied the spICP-MS strategy by comparing different measuring modes available in triple quadrupole ICP-MS. First, single quadrupole mode using the collision/reaction cell system was selected for monitoring the isotope 47 Ti. Different cell gases like He, O 2 and NH 3 were tested under optimised conditions for its applicability in spICP-MS of standard suspensions of TiO 2 . The determined analytical figures of merit were compared to those obtained by triple quadrupole mode using the 47 Ti or 48 Ti reaction products using O 2 and NH 3 as reaction gases. This comparison demonstrated that the triple quadrupole mode (TQ mode) was superior in terms of sensitivity due to the more efficient removal of spectral interferences. Particle size detection limits down to 26nm were obtained using the best instrumental conditions for TiO 2 particles at a dwell time of 10ms. Finally, the different measuring modes were applied to the analysis of chewing gum samples after a simple extraction procedure using an ultrasonic bath. The obtained results showed a good agreement for the detected particle size range using the different TQ modes. The size range of TiO 2 particles was determined to be between approximately 30 and 200nm, whereas roughly 40% of the particles were smaller than 100nm. For the determination of the particle number concentration in these real samples, we suggest CeO 2 particles as internal standard. Copyright © 2017 Elsevier B.V. All rights reserved.
Chen, Tsung-Chi; Fillmore, Thomas L.; Prost, Spencer A.; Moore, Ronald J.; Ibrahim, Yehia M.; Smith, Richard D.
2016-01-01
The electrodynamic ion funnel facilitates efficient focusing and transfer of charged particles in the higher-pressure regions (e.g., ion source interfaces) of mass spectrometers, thus providing increased sensitivity. An “off-axis” ion funnel design has been developed to reduce the source contamination and interferences from, e.g. ESI droplet residue and other poorly focused neutral or charged particles with very high mass-to-charge ratios. In this study, a dual ion funnel interface consisting of an orthogonal higher pressure electrodynamic ion funnel (HPIF) and an ion funnel trap combined with a triple quadrupole mass spectrometer was developed and characterized. An orthogonal ion injection inlet and a repeller plate electrode was used to direct ions to an ion funnel HPIF at a pressure of 9–10 Torr. Key factors for the HPIF performance characterized included the effects of RF amplitude, the DC gradient, and operating pressure. Compared to the triple quadrupole standard interface more than 4-fold improvement in the limit of detection for the direct quantitative MS analysis of low abundance peptides was observed. The sensitivity enhancement in liquid chromatography selected reaction monitoring (LC-SRM) analyses of low-abundance peptides spiked into a highly complex mixture was also compared with that obtained using both a commercial S-lens interface and an in-line dual-ion funnel interface. PMID:26107611
Is the Reaction of C3N(-) with C2H2 a Possible Process for Chain Elongation in Titan's Ionosphere?
Lindén, Fredrik; Alcaraz, Christian; Ascenzi, Daniela; Guillemin, Jean-Claude; Koch, Leopold; Lopes, Allan; Polášek, Miroslav; Romanzin, Claire; Žabka, Jan; Zymak, Illia; Geppert, Wolf D
2016-07-14
The reaction of C3N(-) with acetylene was studied using three different experimental setups, a triple quadrupole mass spectrometer (Trento), a tandem quadrupole mass spectrometer (Prague), and the "CERISES" guided ion beam apparatus at Orsay. The process is of astrophysical interest because it can function as a chain elongation mechanism to produce larger anions that have been detected in Titan's ionosphere by the Cassini Plasma Spectrometer. Three major products of primary processes, C2H(-), CN(-), and C5N(-), have been identified, whereby the production of the cyanide anion is probably partly due to collisional induced dissociation. The formations of all these products show considerable reaction thresholds and also display comparatively small cross sections. Also, no strong signals of anionic products for collision energies lower than 1 eV have been observed. Ab initio calculations have been performed to identify possible pathways leading to the observed products of the title reaction and to elucidate the thermodynamics of these processes. Although the productions of CN(-) and C5N(-) are exoergic, all reaction pathways have considerable barriers. Overall, the results of these computations are in agreement with the observed reaction thresholds. Due to the existence of considerable reaction energy barriers and the small observed cross sections, the title reaction is not very likely to play a major role in the buildup of large anions in cold environments like the interstellar medium or planetary and satellite ionospheres.
NASA Astrophysics Data System (ADS)
Fang, Xiao; Thompson, Todd A.; Hirata, Christopher M.
2018-05-01
We investigate the long-term secular dynamics and Lidov-Kozai (LK) eccentricity oscillations of quadruple systems composed of two binaries at quadrupole and octupole orders in the perturbing Hamiltonian. We show that the fraction of systems reaching high eccentricities is enhanced relative to triple systems, over a broader range of parameter space. We show that this fraction grows with time, unlike triple systems evolved at quadrupole order. This is fundamentally because with their additional degrees of freedom, quadruple systems do not have a maximal set of commuting constants of the motion, even in secular theory at quadrupole order. We discuss these results in the context of star-star and white dwarf-white dwarf (WD) binaries, with emphasis on WD-WD mergers and collisions relevant to the Type Ia supernova problem. For star-star systems, we find that more than 30 per cent of systems reach high eccentricity within a Hubble time, potentially forming triple systems via stellar mergers or close binaries. For WD-WD systems, taking into account general relativistic and tidal precession and dissipation, we show that the merger rate is enhanced in quadruple systems relative to triple systems by a factor of 3.5-10, and that the long-term evolution of quadruple systems leads to a delay-time distribution ˜1/t for mergers and collisions. In gravitational wave-driven mergers of compact objects, we classify the mergers by their evolutionary patterns in phase space and identify a regime in about 8 per cent of orbital shrinking mergers, where eccentricity oscillations occur on the general relativistic precession time-scale, rather than the much longer LK time-scale. Finally, we generalize previous treatments of oscillations in the inner binary eccentricity (evection) to eccentric mutual orbits. We assess the merger rate in quadruple and triple systems and the implications for their viability as progenitors of stellar mergers and Type Ia supernovae.
Sun, Tao; Wetzel, Stephanie J; Johnson, Mitchell E; Surlow, Beth A; Patton-Vogt, Jana
2012-05-15
A highly sensitive hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) method was developed and validated for the quantification of glycerophosphoinositol (GroPIns), glycerophosphocholine (GroPCho), glycerol 3-phosphate (GroP), inositol, and choline in the extracellular medium of Saccharomyces cerevisiae. The media samples were pretreated with a single two-phase liquid extraction. Chromatographic separation was achieved on a Waters Xbridge HILIC (150 mm × 4.6 mm, 5 μm) column under isocratic conditions using a mobile phase composed of acetonitrile/water, 70:30 (v/v) with 10mM ammonium acetate (pH adjusted to 4.5) at a flow-rate of 0.5 mL/min. Using a triple quadrupole tandem mass spectrometer, samples were detected in multiple reaction monitoring (MRM) mode via an electrospray ionization (ESI) source. The calibration curves were linear (r² ≥ 0.995) over the range of 0.5-150 nM, with the lower limit of quantitation validated at 0.5 nM for all analytes. The intra- and inter-day precision (calculated by coefficient of variation, CV%) ranged from 1.24 to 5.88% and 2.46 to 9.77%, respectively, and intra- and inter-day accuracy (calculated by relative error, RE%) was between -8.42 to 8.22% and -9.35 to 6.62%, respectively, at all quality control levels. The extracellular metabolites were stable throughout various storage stability studies. The fully validated method was successfully applied to determine the extracellular levels of phospholipid-related metabolites in S. cerevisiae. Copyright © 2012 Elsevier B.V. All rights reserved.
Kim, Min Kyung; Yang, Dong-Hyug; Jung, Mihye; Jung, Eun Ha; Eom, Han Young; Suh, Joon Hyuk; Min, Jung Won; Kim, Unyong; Min, Hyeyoung; Kim, Jinwoong; Han, Sang Beom
2011-09-16
Methods using high performance liquid chromatography with diode array detection (HPLC-DAD) and tandem mass spectrometry (HPLC-MS/MS) were developed and validated for the simultaneous determination of 5 chromones and 6 coumarins: prim-O-glucosylcimifugin (1), cimifugin (2), nodakenin (3), 4'-O-β-d-glucosyl-5-O-methylvisamminol (4), sec-O-glucosylhamaudol (5), psoralen (6), bergapten (7), imperatorin (8), phellopterin (9), 3'-O-angeloylhamaudol (10) and anomalin (11), in Radix Saposhnikoviae. The separation conditions for HPLC-DAD were optimized using an Ascentis Express C18 (4.6 mm×100 mm, 2.7 μm particle size) fused-core column. The mobile phase was composed of 10% aqueous acetonitrile (A) and 90% acetonitrile (B) and the elution was performed under a gradient mode at a flow rate of 1.0 mL/min. The detection wavelength was set at 300 nm. The HPLC-DAD method yielded a base line separation of the 11 components in 50% methanol extract of Radix Saposhnikoviae with no interfering peaks detected. The HPLC-DAD method was validated in terms of linearity, accuracy and precision (intra- and inter-day), limit of quantification (LOQ), recovery, and robustness. Specific determination of the 11 components was also accomplished by a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization (ESI) source. This HPLC-MS/MS method was also validated by determining the linearity, limit of quantification, accuracy, and precision. Quantification of the 11 components in 51 commercial Radix Saposhnikoviae samples was successfully performed using the developed HPLC-DAD method. The identity, batch-to-batch consistency, and authenticity of Radix Saposhnikoviae were successfully monitored by the proposed HPLC-DAD and HPLC-MS/MS methods. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Shen, X. C.; Zhang, Y. L.; Cui, Y. Q.; Xu, L. Y.; Li, X.; Qi, J. H.
2017-07-01
Heterocyclic aromatic amines (HAAs) are potent mutagens that formed at high temperature in cooked, protein-rich food. Owing to their frequent intake, an accurate method is essential to access human health risk of HAAs exposure through detecting these compounds in various heat-treated meat products. In this study, a liquid chromatography-electrospray tandem mass spectrometry (LC--ESI-MS/MS) method was developed to perform the determination of 9 mutagenic heterocyclic amines (HAAs) in meat samples with multiple reaction monitoring (MRM) mode. Ultrasound assisted extraction and diatomaceous earth was employed to extract HAAs from food samples, and the analytes were purified and enriched using tandem solid phase extraction, with propyl sulfonic acid coupled to a C18 cartridge. Two parameters, extraction time and eluent, were carefully optimized to improve the extraction and purification efficiency. The LC separation was carried out using a Zorbax SB-C18 (3.5 μm particle size, 2.1 × 150 mm i.d.) column and optimized some parameters, such as pH, concentration and volume. Under the optimal experimental conditions, recoveries ranged from 52.97% to 97.11% with good quality parameters: limit of detection values between 0.02 and 0.24 ng mL-1, linearity (R2>0.998), and run-to-run and day-to-day precisions lower than 9.81% achieved. To evaluate the performance of the method in high throughput analysis of complex meat samples, the LC-MS/MS method was applied to the analysis of HAAs in three food samples, and the results demonstrated that the method can be used for the trace determination of HAAs in pork samples.
Leng, Ping; Yang, Zhao; Ma, Baohua; Li, Jing; Sun, Jialin; Xie, Yiming; Sun, Yong
2018-03-05
A compound (WJD-A-1) was previously reported as a candidate prodrug of Am80 (tamibarotene), which was approved in Japan in 2005 as a therapeutic agent for recurrent refractory acute promyelocytic leukaemia. A rapid, selective and sensitive ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed for the first time to simultaneously determine WJD-A-1 and its major phase-I metabolites AM80 in rat plasma. After a simple sample preparation procedure by protein precipitation with methanol and acetonitrile, WJD-A-1, AM80 and the internal standard were chromatographed on an ACQUITY UPLC TM BEH C 18 column. The mobile phase consisted of methanol-0.1% formic acid (80:20, v/v) and the flow rate was 0.20 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI) source. Each plasma sample was chromatographed within 2.6 min. The linear calibration curves for WJD-A-1 and the AM80 were obtained in the concentration range of 5.40-5.40 × 10 3 and 5.08-5.08 × 10 3 ng/mL, respectively (r ≥ 0.99). The intra- and inter-day precision (relative standard deviation, RSD) values were less than 8% and the accuracy (relative error, RE) was within ±6.8%, determined from quality control (QC) samples for the analytes. The method herein described was fully validated and successfully applied to pharmacokinetic study of WJD-A-1 following an intravenous administration of 300 μg/kg WJD-A-1 to rats.
USDA-ARS?s Scientific Manuscript database
In the field of food contaminant analysis, the most significant development of recent years has been the integration of ultra-high pressure liquid chromatography (UHPLC), coupled to tandem quadrupole mass spectrometry (MS/MS), into analytical applications. In this review, we describe the emergence o...
Polymer and Additive Mass Spectrometry Literature Review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shear, Trevor Allan
The use of mass spectrometry in fields related to polymers has increased significantly over the past three decades and will be explored in this literature review. The importance of this technique is highlighted when exploring how polymers degrade, verifying purchased materials, and as internal requirements change. The primary focus will be on four ionization techniques and the triple quadrupole and quadrupole / time-of-flight mass spectrometers. The advantages and limitations of each will also be explored.
NASA Astrophysics Data System (ADS)
Es-Safi, Nour-Eddine; Essassi, El Mokhtar; Massoui, Mohamed; Banoub, Joseph
Mass spectrometry is an important tool for the identification and structural elucidation of natural and synthesized compounds. Its high sensitivity and the possibility of coupling liquid chromatography with mass spectrometry detection make it a technique of choice for the investigation of complex mixtures like raw natural extracts. The mass spectrometer is a universal detector that can achieve very high sensitivity and provide information on the molecular mass. More detailed information can be subsequently obtained by resorting to collision-induced dissociation tandem mass spectrometry (CID-MS/MS). In this review, the application of mass spectrometric techniques for the identification of natural and synthetic compounds is presented. The gas-phase fragmentation patterns of a series of four natural flavonoid glycosides, three synthesized benzodiazepines and two synthesized quinoxalinone derivatives were investigated using electrospray ionization mass spectrometry (ESI-MS) and tandem mass spectrometry techniques. Exact accurate masses were measured using a modorate resolution quadrupole orthogonal time-of-flight QqTOF-MS/MS hybrid mass spectrometer instrument. Confirmation of the molecular masses and the chemical structures of the studied compounds were achieved by exploring the gas-phase breakdown routes of the ionized molecules. This was rationalized by conducting low-energy collision CID-MS/MS analyses (product ion- and precursor ion scans) using a conventional quadrupole hexapole-quadrupole (QhQ) tandem mass spectrometer.
Fu, Qin; Li, Xiaowei; Zheng, Kangni; Ke, Yuebin; Wang, Yingyu; Wang, Lina; Yu, Fugen; Xia, Xi
2018-05-15
A confirmatory method for the determination of colistin in animal tissues, egg, milk, and feed was developed and validated. Colistin A and colistin B were extracted from samples with the mixture of 10% trichloroacetic acid-acetonitrile and isolated with mixed-mode weak cation exchange cartridge. Analytes were separated from matrix components using ultra-high performance liquid chromatography, and detected with electrospray ionization on a triple quadrupole mass spectrometer. Mean recoveries ranged from 78.0% to 115.6% with intra-day and inter-day relative standard deviation lower than 8.4% and 12.4%, respectively. The quantitation limits for different matrices were between 5 and 30 μg/kg, which was satisfactory for surveillance monitoring. The developed method was applied to the analysis of real samples collected from different provinces of China, and 19 out of 348 samples were found to be contaminated, with the highest concentration of approximately 12,000 μg/kg colistin A and 10,000 μg/kg colistin B in feed. Copyright © 2017 Elsevier Ltd. All rights reserved.
A novel nano-carrier transdermal gel against inflammation.
Chaudhary, Hema; Kohli, Kanchan; Kumar, Vikash
2014-04-25
The objective was to develop a stable, reproducible and patient non-infringing novel transdermal drug delivery system "nano-carrier transdermal gel" (NCTG) in combination of partial dose replacement of diclofenac diethylamine (DDEA) by curcumin (CRM). The drug content of gel was 99.30 and 97.57% for DDEA and CRM. Plasma samples were analyzed by liquid chromatography with triple-quadrupole tandem mass spectrometer (LC-MS/MS). Data were integrated with Analyst™ and analyzed by WinNonlin; stability parameters were analyzed using Tukey-Kramer multiple comparison test. Its average skin irritation scored 0.49 concluded to be non-irritant, safe for human use and in vivo studies revealed significantly greater extent of absorption and highly significant inhibition (%) of carrageenan induced paw edema. The results also demonstrated that encapsulation of drugs in nano-carrier increases its biological activity due to superior skin penetration potential. Hence, a novel once day transdermal gel of nano-carrier (nano-transfersomes; deformable vesicular) is achieved, to increase systemic availability, subsequent reduction in dose and toxicity of DDEA was developed for the treatment of inflammation. Copyright © 2014 Elsevier B.V. All rights reserved.
Rood, Johannes J M; van Hoppe, Stephanie; Schinkel, Alfred H; Schellens, Jan H M; Beijnen, Jos H; Sparidans, Rolf W
2016-01-25
A validated simple, fast and sensitive bio-analytical assay for ibrutinib and its dihydrodiol metabolite in human and mouse plasma was set up. Sample preparation was performed by protein precipitation, and addition of the respective deuterated internal standards, followed by LC-MS/MS analysis. Separation was performed on a 3.5 μm particle-size, bridged ethylene hybrid column with gradient elution by 0.1% v/v formic acid and acetonitrile. The full eluate was transferred to an electrospray interface in positive ionization mode, and subsequently analyzed by a triple quadrupole mass spectrometer by selected reaction monitoring. The assay was validated in a 5-5000 ng/ml calibration range. Both ibrutinib and dihydrodiol-ibrutinib were deemed stable under refrigerated or frozen storage conditions. At room temperature, ibrutinib showed a not earlier described instability, and revealed rapid degradation at 37 °C. Finally, the assay was used for a pharmacokinetic study of plasma levels in treated FVB mice. Copyright © 2015 Elsevier B.V. All rights reserved.
Tsang, Vic Wing-Hang; Lei, Ngai-Yu; Lam, Michael Hon-Wah
2009-10-01
A mild, low-temperature analytical approach based on sonication assisted extraction coupled with HPLC electrospray ionization triple quadrupole tandem mass spectrometry has been developed for the simultaneous qualitative and quantitative determination of the four Irgarol-related s-triazine species, namely Irgarol-1051, M1, M2 and M3, in coastal sediments and Green-lipped mussel samples. Mild extraction conditions were necessary for the preservation of the thermally unstable M2. The Multiple Reaction Monitoring (MRM) mode of detection by ESI-MS/MS enabled reliable qualitative identification and sensitive quantitative determination of those s-triazines. This determination method was applied to evaluate the degree of Irgarol-1051 contamination in the sediments and biota of the coastal environment of Hong Kong--one of the busiest maritime ports in the world. All the four s-triazine species were observed in all of the samples. This is the first time that the newly identified M2 and M3 are detected in coastal sediments and biota tissues.
Tush, Daniel; Loftin, Keith A.; Meyer, Michael T.
2013-01-01
Little is known about the occurrence, fate, and effects of the ancillary additives in pesticide formulations. Polyoxyethylene tallow amine (POEA) is a non-ionic surfactant used in many glyphosate formulations, a widely applied herbicide both in agricultural and urban environments. POEA has not been previously well characterized, but has been shown to be toxic to various aquatic organisms. Characterization of technical mixtures using ultra-high performance liquid chromatography (UHPLC) and mass spectrometry shows POEA is a complex combination of homologs of different aliphatic moieties and ranges of ethoxylate units. Tandem mass spectrometry experiments indicate that POEA homologs generate no product ions readily suitable for quantitative analysis due to poor sensitivity. A comparison of multiple high performance liquid chromatography (HPLC) and UHPLC analytical columns indicates that the stationary phase is more important in column selection than other parameters for the separation of POEA. Analysis of several agricultural and household glyphosate formulations confirms that POEA is a common ingredient but ethoxylate distributions among formulations vary.
Pastor-Belda, Marta; Garrido, Isabel; Campillo, Natalia; Viñas, Pilar; Hellín, Pilar; Flores, Pilar; Fenoll, José
2016-07-01
Dispersive liquid-liquid microextraction was used to preconcentrate three spirocyclic tetronic/tetramic acid derivatives (spirotetramat, spiromesifen and spirodiclofen) and five neonicotinoid (thiamethoxam, chlotianidin, imidacloprid, acetamiprid and thiacloprid) insecticides previously extracted from fruit and vegetable matrices with acetonitrile. The organic enriched phase was evaporated, reconstituted in 25μL acetonitrile and analyzed by reversed-phase liquid chromatography with tandem mass spectrometry using a triple quadrupole in selected reaction monitoring mode. Enrichment factors in the 15-100 range were obtained. A matrix effect was observed, the detection limits varying between 0.025 and 0.5ngg(-1), depending on the compound and the sample matrix. The developed method was applied to the analysis of 25 samples corresponding to five different fruit and vegetable matrices. Only thiamethoxam was detected in a lemon sample at a concentration close to the quantification limit, and spiromesifen and spirotetramat at concentrations between 11.6 and 54.5ngg(-1). Copyright © 2016 Elsevier Ltd. All rights reserved.
Regal, P; Nebot, C; Vázquez, B I; Cepeda, A; Fente, C A
2010-01-01
This paper describes the development, validation and application of a confirmatory method to detect 17alpha-methyltestosterone (MT) in bovine hair, to aid in controlling the administration of this growth promoter in meat-producing animals. After cryogenic grinding, MT was removed from the hair matrix using a single step extraction procedure with acetonitrile. Hydroxylamine derivatisation was used to enhance analyte determination with an electrospray ionisation (ESI) source. Determination was carried out using a triple quadrupole liquid chromatography tandem mass spectrometer (LC-MS/MS) in multiple reaction monitoring mode (MRM). The method was validated in accordance with the criteria defined in Commission Decision 2002/657/EC and using deuterated testosterone (T-d(3)) as the internal standard. The decision limit (CCalpha) was 0.07 ng g(-1) and the detection capability (CCbeta) was 0.12 ng g(-1). Repeatability was CV% (7%), within-laboratory reproducibility was CV% (11.0%), and trueness was (87%). Applicability of the method was demonstrated in an animal study. Samples obtained from animal experiments were analyzed and the presence of MT was confirmed.
Portable Tandem Mass Spectrometer Analyzer
1991-07-01
The planned instrument was to be small enough to be portable in small vehicles and was to be able to use either an atmospheric pressure ion source or a...conventional electron impact/chemical ionization ion source. In order to accomplish these developments an atmospheric pressure ionization source was...developed for a compact, commercially available tandem quadrupole mass spectrometer. This ion source could be readily exchanged with the conventional
Huang, Ke; Huang, Lingyi; van Breemen, Richard B
2015-04-07
Metabolic activation of drugs to electrophilic species is responsible for over 60% of black box warnings and drug withdrawals from the market place in the United States. Reactive metabolite trapping using glutathione (GSH) and analysis using high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) or HPLC with high resolution mass spectrometry (mass defect filtering) have enabled screening for metabolic activation to become routine during drug development. However, current MS-based approaches cannot detect all GSH conjugates present in complex mixtures, especially those present in extracts of botanical dietary supplements. To overcome these limitations, a fast triple quadrupole mass spectrometer-based approach was developed that can detect positively and negatively charged GSH conjugates in a single analysis without the need for advanced knowledge of the elemental compositions of potential conjugates and while avoiding false positives. This approach utilized UHPLC instead of HPLC to shorten separation time and enhance sensitivity, incorporated stable-isotope labeled GSH to avoid false positives, and used fast polarity switching electrospray MS/MS to detect GSH conjugates that form positive and/or negative ions. The general new method was then used to test the licorice dietary supplement Glycyrrhiza glabra, which was found to form multiple GSH conjugates upon metabolic activation. Among the GSH conjugates found in the licorice assay were conjugates with isoliquiritigenin and glabridin, which is an irreversible inhibitor of cytochrome P450 enzymes.
Alpha particle confinement in tandem mirrors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Devoto, R.S.; Ohnishi, M.; Kerns, J.
1980-10-10
Mechanisms leading to loss of alpha particles from non-axisymmetric tandem mirrors are considered. Stochastic diffusion due to bounce-drift resonances, which can cause rapid radial losses of high-energy alpha particles, can be suppressed by imposing a 20% rise in axisymmetric fields before the quadrupole transition sections. Alpha particles should then be well-confined until thermal energies when they enter the resonant plateau require. A fast code for computation of drift behavior in reactors is described. Sample calculations are presented for resonant particles in a proposed coil set for the Tandem Mirror Next Step.
Camacho-Muñoz, Dolores; Kasprzyk-Hordern, Barbara; Thomas, Kevin V
2016-08-31
In order to assess the true impact of each single enantiomer of pharmacologically active compounds (PACs) in the environment, highly efficient, fast and sensitive analytical methods are needed. For the first time this paper focuses on the use of ultrahigh performance supercritical fluid based chromatography coupled to a triple quadrupole mass spectrometer to develop multi-residue enantioselective methods for chiral PACs in environmental matrices. This technique exploits the advantages of supercritical fluid chromatography, ultrahigh performance liquid chromatography and mass spectrometry. Two coated modified 2.5 μm-polysaccharide-based chiral stationary phases were investigated: an amylose tris-3,5-dimethylphenylcarbamate column and a cellulose tris-3-chloro-4-methylphenylcarbamate column. The effect of different chromatographic variables on chiral recognition is highlighted. This novel approach resulted in the baseline resolution of 13 enantiomers PACs (aminorex, carprofen, chloramphenicol, 3-N-dechloroethylifosfamide, flurbiprofen, 2-hydroxyibuprofen, ifosfamide, imazalil, naproxen, ofloxacin, omeprazole, praziquantel and tetramisole) and partial resolution of 2 enantiomers PACs (ibuprofen and indoprofen) under fast-gradient conditions (<10 min analysis time). The overall performance of the methods was satisfactory. The applicability of the methods was tested on influent and effluent wastewater samples. To the best of our knowledge, this is the first feasibility study on the simultaneous separation of chemically diverse chiral PACs in environmental matrices using ultrahigh performance supercritical fluid based chromatography coupled with tandem mass spectrometry. Copyright © 2016 Elsevier B.V. All rights reserved.
Kretschmer, Philip M; Bannister, Austin M; O Brien, Molly K; MacManus-Spencer, Laura A; Paulick, Margot G
2016-10-15
Trehalose is an important disaccharide that is used as a cellular protectant by many different organisms, helping these organisms better survive extreme conditions, such as dehydration, oxidative stress, and freezing temperatures. Methods to detect and accurately measure trehalose from different organisms will help us gain a better understanding of the mechanisms behind trehalose's ability to act as a cellular protectant. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay using selected reaction monitoring mode for the detection and quantification of trehalose using maltose as an internal standard has been developed. This assay uses a commercially available LC column for trehalose separation and a standard triple quadrupole mass spectrometer, thus allowing many scientists to take advantage of this simple assay. The calibration curve from 3 to 100μM trehalose was fit best by a single polynomial. This LC-MS/MS assay directly detects and accurately quantifies trehalose, with an instrument limit of detection (LOD) that is 2-1000 times more sensitive than the most commonly-used assays for trehalose detection and quantification. Furthermore, this assay was used to detect and quantify endogenous trehalose produced by Escherichia coli (E. coli) cells, which were found to have an intracellular concentration of 8.5±0.9mM trehalose. This method thus shows promise for the reliable detection and quantification of trehalose from different biological sources. Copyright © 2016 Elsevier B.V. All rights reserved.
Tao, Weiwei; Duan, Jinao; Guo, Jianming; Li, Jianping; Tang, Yuping; Liu, Pei; Yang, Nianyun
2013-03-05
A rapid and sensitive ultra performance liquid chromatography-tandem mass spectrometry method was developed for simultaneous determination of eight constituents, uralsaponin C, uralsaponin F, 22β-acetoxyl-glycyrrhizin, 24-hydroxy-licorice-saponin E2, licorice-saponin G2, licorice-saponin E2, glycyrrhizin, and licorice-saponin J2, from total saponin of licorice (TSL) in dog plasma. Ardisiacrispin A was used as the internal standard (IS). The separation was performed on Thermo Syncronic C₁₈ column (100 mm × 2.1 mm, 1.7 μm) at a flow rate of 0.4 mL min⁻¹, and acetonitrile/methanol (3:1, v/v)-0.1% formic acid was used as mobile phase. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) via electrospray ionization (ESI) source with negative ionization mode. All calibration curves had good linearity (r>0.991) over the concentration range from 2.03-405 ng mL⁻¹ to 2.63-2625 ng mL⁻¹ for all components. The intra- and inter-day precision was within 15% and the accuracy ranged from -14.08% to 13.8%. The method was successfully applied to pharmacokinetic study of eight triterpenoid saponins in dog plasma after oral administration of TSL. Crown Copyright © 2012. Published by Elsevier B.V. All rights reserved.
Zhang, Pin; Zhang, Jing; Shi, Ying; Shao, Bing
2015-03-01
An analytical method was developed to simultaneously detect triclosan (TCS) and triclocarban (TCC) in human breast milk using solid-phase extraction (SPE) with ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Samples were extracted by acetonitrile and purified with C -18 SPE cartridge after enzymolysis with β-glucuronidase/arylsulfatase. The chromatographic separation was performed on a Waters ACQUITY UPLC™ HSS T3 column (100 mm x 2. 1 mm, 1. 8 µm) with gradient elution using methanol and water at a flow rate of 0. 3 ml/min. The target analytes were assayed by triple quadrupole mass spectrometer operating in the negative ion mode. Quantification was performed by isotopic internal standard calibration. Satisfactory linearity (r2 > 0. 999) was obtained over the range of 0. 2 - 20. 0 µg/L and 0. 02 - 2. 0 µg/L for triclosan and triclocarban, respectively, with the limits of quantifications (LOQs) of 0. 41 and 0. 03 µg/kg. Average recoveries of two target compounds (spiked at three concentration levels) ranged from 100. 2% to 119. 3%, with the relative standard deviations (RSDs) between 5. 91% and 11. 31% (n =6). Twenty-five real samples (n = 25) were detected containing TCS and TCC at concentrations of < LOQ - 0. 77 µg/kg and < LOQ - 4. 28 µg/kg, respectively. Due to its high sensitivity and good reproductivity, this method can be applied to analyze TCS and TCC in human breast milk.
Zhao, Ai-qin; Zhao, Ji-hong; Zhang, Shu-qing; Pan, Yong-yang; Huo, Xu-lei
2016-02-05
A rapid, sensitive and selective ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the determination and pharmacokinetic investigation of parthenolide in rat plasma. Sample preparation was accomplished through a simple one-step deproteinization procedure with 0.2mL of acetonitrile containing 30ng/mL of pirfenidone (IS), and to a 0.1mL plasma sample. Plasma samples were separated by UPLC on an Acquity UPLC BEH C18 column using a mobile phase consisting of acetonitrile-0.1% formic acid in water with gradient elution. The total run time was 3.0min and the elution of parthenolide was at 1.33min. The detection was performed on a triple quadrupole tandem mass spectrometer in the multiple reaction-monitoring (MRM) mode using the respective transitions m/z 249.2→231.1 for parthenolide and m/z 186.2→92.1 for pirfenidone (IS), respectively. The calibration curve was linear over the range of 2.0-500ng/mL with a lower limit of quantitation (LLOQ) of 2.0ng/mL. Mean recovery of parthenolide in plasma was in the range of 78.2-86.6%. Intra-day and inter-day precision were both <8.3%. This method was successfully applied in pharmacokinetic study after oral and intravenous administration of parthenolide in rats. Copyright © 2015 Elsevier B.V. All rights reserved.
Lucentini, Luca; Ferretti, Emanuele; Veschetti, Enrico; Achene, Laura; Turrio-Baldassarri, Luigi; Ottaviani, Massimo; Bogialli, Sara
2009-01-01
A simple and sensitive liquid chromatographic-tandem mass spectrometric (LC/MS/MS) method has been developed and validated to confirm and quantify acrylamide monomer (AA) in drinking water using [13C3] acrylamide as internal standard (IS). After a preconcentration by solid-phase extraction with spherical activated carbon, analytes were chromatographed on IonPac ICE-AS1 column (9 x 250 mm) under isocratic conditions using acetonitrile-water-0.1 M formic acid (43 + 52 + 5, v/v/v) as the mobile phase. Analysis was achieved using a triple-quadrupole mass analyzer equipped with a turbo ion spray interface. For confirmation and quantification of the analytes, MS data acquisition was performed in the multireaction monitoring mode, selecting 2 precursor ion to product ion transitions for both AA and IS. The method was validated for linearity, sensitivity, accuracy, precision, extraction efficiency, and matrix effect. Linearity in tap water was observed over the concentration range 0.1-2.0 microg/L. Limits of detection and quantification were 0.02 and 0.1 microg/L, respectively. Interday and intraday assays were performed across 3 validation levels (0.1, 0.5, and 1.5 microg/L). Accuracy (as mean recovery) ranged from 89.3 to 96.2% with relative standard deviation <7.98%. Performance characteristics of this LC/MS/MS method make it suitable for regulatory confirmatory analysis of AA in drinking water in compliance with European Union and U.S. Environmental Protection Agency standards.
Yuan, Yin; Zhou, Xuan; Li, Jian; Ye, Suofu; Ji, Xiwei; Li, Liang; Zhou, Tianyan; Lu, Wei
2015-04-01
In the current study, a simple, sensitive and rapid analytical method for the determination of dexamethasone was developed and applied to a pharmacokinetic study in nude mice. Using testosterone as an internal standard, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) approach after one-step precipitation with acetonitrile was validated and used to determine the concentrations of dexamethasone in nude mice plasma. The method utilized a simple isocratic reverse phase separation over a Dionex C18 column with a mobile phase composed of acetonitrile-water (40:60, v/v). The analyte was detected by a triple quadrupole tandem mass spectrometer via electrospray and multiple reaction monitoring was employed to select both dexamethasone at m/z 393.0/147.1 and testosterone at m/z 289.5/97.3 in the positive ion mode. The calibration curves were linear (r >0.99) ranging from 2.5 to 500 ng/mL with a lower limit of quantitation of 2.5 ng/mL. The relative standard deviation ranged from 1.69 to 9.22% while the relative error ranged from -1.92 to -8.46%. This method was successfully applied to a preclinical pharmacokinetic study of dexamethasone and its pharmacokinetics was characterized by a two-compartment model with first-order absorption in female nude mice. Copyright © 2014 John Wiley & Sons, Ltd.
Socas-Rodríguez, Bárbara; Hernández-Borges, Javier; Herrera-Herrera, Antonio V; Rodríguez-Delgado, Miguel Ángel
2018-03-01
In this work, the suitability of Fe 3 O 4 nanoparticles coated with polydopamine was evaluated as sorbent for the extraction of a group of 21 compounds with oestrogenic activity including seven phytoestrogens, six mycotoxins as well as four synthetic and four natural oestrogens from different types of milk, including sheep milk, in which the evaluation of oestrogenic compounds have never been developed before. Extraction was carried out using magnetic micro-dispersive solid-phase extraction after a previous deproteinisation step. Separation, determination and quantification of the target analytes were achieved by ultra-high-performance liquid chromatography coupled to triple quadrupole-tandem mass spectrometry. The methodology was validated for five milk samples using 17β-estradiol-2,4,16,16,17-d 5 as internal standard for natural and synthetic oestrogens, β-zearalanol-10,10,11,12,12-d 5 for mycotoxins and prunetin for phytoestrogens. Recovery values ranged from 70 to 120% for the five types of matrices with relative standard deviation values lower than 18%. Limits of quantification of the method were in the range 0.55-11.8 μg L -1 for all samples. Graphical abstract General scheme of the multiresidue analysis of oestrogenic compounds in milk using core-shell polydopamine coated magnetic nanoparticles as extraction sorbent in μ-dSPE.
Farré, Maria José; Insa, Sara; Mamo, Julian; Barceló, Damià
2016-08-05
A new methodology based on on-line solid-phase extraction (SPE) ultra-high-performance-liquid chromatography coupled to a triple quadrupole mass spectrometer (UHPLC-MS-MS) for the determination of 15 individual anthropogenic N-nitrosodimethylamine (NDMA) precursors was developed. On-line SPE was performed by passing 2mL of the water sample through a Hypersil GOLD aQ column and chromatographic separation was done using a Kinetex Biphenyl column using methanol and 0.1% formic acid aqueous solution as a mobile phase. For unequivocal identification and confirmation, two selected reaction monitoring (SRM) transitions were monitored per compound. Quantification was performed by internal standard approach and matrix match calibration. The main advantages of the developed method are high sensitivity (limits of detection in the sub ng/L range), selectivity due to the use of tandem mass spectrometry, precision and minimum sample manipulation as well as fast analytical response. Process efficiency and recovery were also evaluated for all the target compounds. As part of the validation procedure, the method was applied in a sampling campaign for the analysis of influent and secondary effluent of a wastewater treatment plant (WWTP) in Girona, Spain. Additionally, the effluent from a nanofiltration (NF) membrane system used for water recycling was monitored. The percentage of NDMA formation explained by the measured precursors was also quantified. Copyright © 2016 Elsevier B.V. All rights reserved.
Luo, Guanzhong; Li, Youxin; Bao, James J
2016-02-01
A novel high-throughput sample pretreatment system was developed by the integration of protein precipitation (PP), phospholipid removal (PPR), and hollow fiber liquid-phase microextraction (HF-LPME) into two simple 96-well plates and a matching 96-grid lid. With this system, 16 steroids were separated from biological matrices of plasma, milk, and urine and analyzed by liquid chromatography-triple quadrupole mass spectrometry. In the tandem sample cleanup process, the prepositive PP and PPR step preliminarily removed some of the interferences from the biological matrices. The following HF-LPME step kept the residual interference out of the hollow fiber and enriched the steroids in the hollow fiber to achieve high sensitivity. By a series of method optimizations, acetonitrile was chosen as the crash solvent for PP and PPR. A mixture of octanol and toluene (1:1 v/v) was used as the acceptor phase for HF-LPME. The extraction was conducted at 80 rpm for 50 min in a donor phase containing 1 mL 20% sodium chloride at 25 °C. Under these conditions, the limits of detection for the 16 steroids were 3.6-300.0 pg(.)mL(-1) in plasma, 3.0-270.0 pg·mL(-1) in milk, and 2.2-210.0 pg(.)mL(-1) in urine. The recoveries of the 16 steroids were 81.9-97.9% in plasma (relative standard deviation 1.0-8.0%), 80.6-97.7% in milk (relative standard deviation 0.8-5.4%), and 87.3-98.7% in urine (relative standard deviation 1.0-4.9%). Further, the integrated 96-well platform of PP, PPR, and HF-LPME enabled us to run this assay in an automatic and high-throughput fashion. The reliability of the method was further corroborated by evaluation of its applicability in plasma and urine samples from volunteers and fresh bovine milk from local dairy enterprises.
Sun, Mingqian; Liu, Jianxun; Lin, Chengren; Miao, Lan; Lin, Li
2014-01-01
Since alkaloids are the major active constituents of Rhizoma corydalis (RC), a convenient and accurate analytical method is needed for their identification and characterization. Here we report a method to profile the alkaloids in RC based on liquid chromatography-tandem quadrupole time-of-flight mass spectrometry (LC–Q-TOF-MS/MS). A total of 16 alkaloids belonging to four different classes were identified by comparison with authentic standards. The fragmentation pathway of each class of alkaloid was clarified and their differences were elucidated. Furthermore, based on an analysis of fragmentation pathways and alkaloid profiling, a rapid and accurate method for the identification of unknown alkaloids in RC is proposed. The method could also be useful for the quality control of RC. PMID:26579385
Sun, Hao; Luo, Guangwen; Xiang, Zheng; Cai, Xiaojun; Chen, Dahui
2016-12-01
The selection of effect indicators in the pharmacokinetic/ pharmacodynamic study of complex diseases to describe the relationship between plasma concentration and effect indicators is difficult. Three effect indicators of renal fibrosis were successfully determined. The relationship between pharmacokinetics and pharmacodynamics of rhein in rhubarb was elucidated. The study was a metabolomics analysis of rat plasma and pharmacokinetics/ pharmacodynamics of rhein. A sensitive and simple ultra performance liquid chromatography-tandem triple quadrupole mass spectrometry (UPLC-MS/MS) method was applied to determine the rhein plasma concentration in the rat model of renal fibrosis and rat sham-operated group after the administration of rhubarb decoction. Then, the ultra performance liquid chromatography-Micromass quadrupole-time of flight mass spectrometry (UPLC-QTOF/MS) metabolomics method was used to screen biomarkers of renal fibrosis in rat plasma. Furthermore, the relationship between the plasma concentration of rhein and the concentration of three biomarkers directly related to renal fibrosis were analyzed. The three screened biomarkers could represent the effect of rhein treatment on renal fibrosis. Increasing the plasma concentration of rhein tended to restore the concentration of the three biomarkers in the model group compared with that in the sham-operated group. Evident differences in the area under the plasma concentration-time curve (AUC) of rhein were also observed under different pathological states. The results provide valuable information for the clinical application of rhubarb. Rhein intervention could recover the physiological balance in living organisms from the pharmacokinetic/pharmacodynamic levels. New information on the pharmacokinetic/pharmacodynamic study of complex diseases is provided. Copyright © 2016 Elsevier GmbH. All rights reserved.
Canon, Francis; Paté, Franck; Meudec, Emmanuelle; Marlin, Thérèse; Cheynier, Véronique; Giuliani, Alexandre; Sarni-Manchado, Pascale
2009-12-01
Numerous protein-polyphenol interactions occur in biological and food domains particularly involving proline-rich proteins, which are representative of the intrinsically unstructured protein group (IUP). Noncovalent protein-ligand complexes are readily detected by electrospray ionization mass spectrometry (ESI-MS), which also gives access to ligand binding stoichiometry. Surprisingly, the study of interactions between polyphenolic molecules and proteins is still an area where ESI-MS has poorly benefited, whereas it has been extensively applied to the detection of noncovalent complexes. Electrospray ionization mass spectrometry has been applied to the detection and the characterization of the complexes formed between tannins and a human salivary proline-rich protein (PRP), namely IB5. The study of the complex stability was achieved by low-energy collision-induced dissociation (CID) measurements, which are commonly implemented using triple quadrupole, hybrid quadrupole time-of-flight, or ion trap instruments. Complexes composed of IB5 bound to a model polyphenol EgCG have been detected by ESI-MS and further analyzed by MS/MS. Mild ESI interface conditions allowed us to observe intact noncovalent PRP-tannin complexes with stoichiometries ranging from 1:1 to 1:5. Thus, ESI-MS shows its efficiency for (1) the study of PRP-tannin interactions, (2) the determination of stoichiometry, and (3) the study of complex stability. We were able to establish unambiguously both their stoichiometries and their overall subunit architecture via tandem mass spectrometry and solution disruption experiments. Our results prove that IB5.EgCG complexes are maintained intact in the gas phase.
NASA Astrophysics Data System (ADS)
Konda, Chiharu; Londry, Frank A.; Bendiak, Brad; Xia, Yu
2014-08-01
A systematic approach is described that can pinpoint the stereo-structures (sugar identity, anomeric configuration, and location) of individual sugar units within linear oligosaccharides. Using a highly modified mass spectrometer, dissociation of linear oligosaccharides in the gas phase was optimized along multiple-stage tandem dissociation pathways (MSn, n = 4 or 5). The instrument was a hybrid triple quadrupole/linear ion trap mass spectrometer capable of high-efficiency bidirectional ion transfer between quadrupole arrays. Different types of collision-induced dissociation (CID), either on-resonance ion trap or beam-type CID could be utilized at any given stage of dissociation, enabling either glycosidic bond cleavages or cross-ring cleavages to be maximized when wanted. The approach first involves optimizing the isolation of disaccharide units as an ordered set of overlapping substructures via glycosidic bond cleavages during early stages of MSn, with explicit intent to minimize cross-ring cleavages. Subsequently, cross-ring cleavages were optimized for individual disaccharides to yield key diagnostic product ions ( m/ z 221). Finally, fingerprint patterns that establish stereochemistry and anomeric configuration were obtained from the diagnostic ions via CID. Model linear oligosaccharides were derivatized at the reducing end, allowing overlapping ladders of disaccharides to be isolated from MSn. High confidence stereo-structural determination was achieved by matching MSn CID of the diagnostic ions to synthetic standards via a spectral matching algorithm. Using this MSn ( n = 4 or 5) approach, the stereo-structures, anomeric configurations, and locations of three individual sugar units within two pentasaccharides were successfully determined.
Kang, Kyungsu; Peng, Lei; Jung, Yu-Jin; Kim, Joo Yeon; Lee, Eun Ha; Lee, Hee Ju; Kim, Sang Min; Sung, Sang Hyun; Pan, Cheol-Ho; Choi, Yongsoo
2018-02-01
To develop a high-throughput screening system to measure the conversion of testosterone to dihydrotestosterone (DHT) in cultured human prostate cancer cells using turbulent flow chromatography liquid chromatography-triple quadrupole mass spectrometry (TFC-LC-TQMS). After optimizing the cell reaction system, this method demonstrated a screening capability of 103 samples, including 78 single compounds and 25 extracts, in less than 12 h without manual sample preparation. Consequently, fucoxanthin, phenethyl caffeate, and Curcuma longa L. extract were validated as bioactive chemicals that inhibited DHT production in cultured DU145 cells. In addition, naringenin boosted DHT production in DU145 cells. The method can facilitate the discovery of bioactive chemicals that modulate the DHT production, and four phytochemicals are potential candidates of nutraceuticals to adjust DHT levels in male hormonal dysfunction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bodin, A.; Laloo, R.; Abeilhou, P.
2013-09-15
We have developed an energy-filtering device coupled to a quadrupole mass spectrometer to deposit ionized molecules on surfaces with controlled energy in ultra high vacuum environment. Extensive numerical simulations as well as direct measurements show that the ion beam flying out of a quadrupole exhibits a high-energy tail decreasing slowly up to several hundred eV. This energy distribution renders impossible any direct soft-landing deposition of molecular ions. To remove this high-energy tail by energy filtering, a 127° electrostatic sector and a specific triplet lenses were designed and added after the last quadrupole of a triple quadrupole mass spectrometer. The resultsmore » obtained with this energy-filtering device show clearly the elimination of the high-energy tail. The ion beam that impinges on the sample surface satisfies now the soft-landing criterion for molecular ions, opening new research opportunities in the numerous scientific domains involving charges adsorbed on insulating surfaces.« less
Duvivier, Wilco F; van Beek, Teris A; Nielen, Michel W F
2016-11-15
Recently, several direct and/or ambient mass spectrometry (MS) approaches have been suggested for drugs of abuse imaging in hair. The use of mass spectrometers with insufficient selectivity could result in false-positive measurements due to isobaric interferences. Different mass analyzers have been evaluated regarding their selectivity and sensitivity for the detection of Δ9-tetrahydrocannabinol (THC) from intact hair samples using direct analysis in real time (DART) ionization. Four different mass analyzers, namely (1) an orbitrap, (2) a quadrupole orbitrap, (3) a triple quadrupole, and (4) a quadrupole time-of-flight (QTOF), were evaluated. Selectivity and sensitivity were assessed by analyzing secondary THC standard dilutions on stainless steel mesh screens and blank hair samples, and by the analysis of authentic cannabis user hair samples. Additionally, separation of isobaric ions by use of travelling wave ion mobility (TWIM) was investigated. The use of a triple quadrupole instrument resulted in the highest sensitivity; however, transitions used for multiple reaction monitoring were only found to be specific when using high mass resolution product ion measurements. A mass resolution of at least 30,000 FWHM at m/z 315 was necessary to avoid overlap of THC with isobaric ions originating from the hair matrix. Even though selectivity was enhanced by use of TWIM, the QTOF instrument in resolution mode could not indisputably differentiate THC from endogenous isobaric ions in drug user hair samples. Only the high resolution of the (quadrupole) orbitrap instruments and the QTOF instrument in high-resolution mode distinguished THC in hair samples from endogenous isobaric interferences. As expected, enhanced selectivity compromises sensitivity and THC was only detectable in hair from heavy users. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Xu, Xiao-min; He, Hua-li; Zhu, Yan; Feng, Liang; Ying, Ying; Huang, Bai-fen; Shen, Hai-tao; Han, Jian-long; Ren, Yi-ping
2013-01-14
Both 3-monochloropropane-1,2-diol (3-MCPD) and acrylamide are contaminants found in heat-processed foods and their related products. A quantitative method was developed for the simultaneous determination of both contaminants in food by gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS). The analytes were purified and extracted by the matrix solid-phase dispersion extraction (MSPDE) technique with Extrelut NT. A coupled column (a 3 m Innowax combined with a 30 m DB-5 ms) was developed to separate both compounds efficiently without derivatization. Triple quadrupole mass spectrometry in multiple reaction monitoring mode (MRM) was applied to suppress matrix interference and obtain good sensitivity in the determination of both analytes. The limit of detection (LOD) in the sample matrix was 5 μg kg(-1) for 3-MCPD or acrylamide. The average recoveries for 3-MCPD and acrylamide in different food matrices were 90.5-107% and 81.9-95.7%, respectively, with the intraday relative standard deviations (RSDs) of 5.6-13.5% and 5.3-13.4%, respectively. The interday RSDs were 6.1-12.6% for 3-MCPD and were 5.0-12.8% for acrylamide. Both contaminants were found in samples of bread, fried chips, fried instant noodles, soy sauce, and instant noodle flavoring. Neither 3-MCPD nor acrylamide was detected in the samples of dairy products (solid or liquid samples) and non-fried instant noodles. Copyright © 2012 Elsevier B.V. All rights reserved.
Rathore, Atul S; Sathiyanarayanan, L; Deshpande, Shreekant; Mahadik, Kakasaheb R
2016-11-01
A rapid and sensitive method for the extraction and determination of four major polyphenolic components in Euphoria longana Lam. seeds is presented for the first time based on matrix solid-phase dispersion extraction followed by ultra high performance liquid chromatography with hybrid triple quadrupole linear ion trap mass spectrometry. Matrix solid-phase dispersion method was designed for the extraction of Euphoria longana seed constituents and compared with microwave-assisted extraction and ultrasonic-assisted extraction methods. An Ultra high performance liquid chromatography with hybrid triple quadrupole linear ion-trap mass spectrometry method was developed for quantitative analysis in multiple-reaction monitoring mode in negative electrospray ionization. The chromatographic separation was accomplished using an ACQUITY UPLC BEH C 18 (2.1 mm × 50 mm, 1.7 μm) column with gradient elution of 0.1% aqueous formic acid and 0.1% formic acid in acetonitrile. The developed method was validated with acceptable linearity (r 2 > 0.999), precision (RSD ≤ 2.22%) and recovery (RSD ≤ 2.35%). The results indicated that matrix solid-phase dispersion produced comparable extraction efficiency compared with other methods nevertheless was more convenient and time-saving with reduced requirements on sample and solvent volumes. The proposed method is rapid and sensitive in providing a promising alternative for extraction and comprehensive determination of active components for quality control of Euphoria longana products. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amundson, Lucas M.; Owen, Ben C.; Gallardo, Vanessa A.
2011-01-01
Positive-mode atmospheric pressure chemical ionization tandem mass spectrometry (APCI-MS n ) was tested for the differentiation of regioisomeric aromatic ketocarboxylic acids. Each analyte forms exclusively an abundant protonated molecule upon ionization via positive-mode APCI in a commercial linear quadrupole ion trap (LQIT) mass spectrometer. Energy-resolved collision-activated dissociation (CAD) experiments carried out on the protonated analytes revealed fragmentation patterns that varied based on the location of the functional groups. Unambiguous differentiation between the regioisomers was achieved in each case by observing different fragmentation patterns, different relative abundances of ion-molecule reaction products, or different relative abundances of fragment ions formed at differentmore » collision energies. The mechanisms of some of the reactions were examined by H/D exchange reactions and molecular orbital calculations.« less
Tian, He; Wang, Jiaqi; Zhang, Yangdong; Li, Songli; Jiang, Jindou; Tao, Dali; Zheng, Nan
2016-10-15
A simple and fast multiresidue extraction and purification method was developed for the determination of 61 veterinary drugs, belonging to seven classes, in milk and milk powder. The extraction depends on the acetonitrile solvent, followed by a single step to remove lipids with fatty acid chains using a new reversed phase SPE without traditional pre-equilibration and washing steps before eluting SPE. The purifying lipid effect of the present preparation method was evaluated by comparing the response changes of ion peak areas of the milk endogenous metabolites before and after SPE treatment using ultra-fast LC coupled to tandem quadrupole and TOF MS. Subsequently, UPLC coupled to tandem quadrupole MS was performed for the quantitative analysis of milk and milk powder samples spiked with 61 veterinary drugs, including β-lactam, macrolide, amide alcohol, forest amine, sulfanilamide, tetracyclines, and quinolones antibiotics. This method is very simple, fast, sensitive, and selective, and allows the good recoveries of all compounds, with a recovery range of 61.5-118.6%, and coefficients of variation of less than 11.6%. The 61 compounds behave in the dynamic range 0.01-200μgkg(-1), with correlation coefficient >0.99. The limits of quantification for the analytes are in the range 0.01-5.18μgkg(-1). Finally, this method has been successfully applied to the screening of veterinary drugs in 50 commercial bovine milk and milk powder samples, and ceftiofur and ciprofloxacin were detected in some brand samples. Copyright © 2016 Elsevier B.V. All rights reserved.
A/C Interface: Expert Systems: Part II.
ERIC Educational Resources Information Center
Dessy, Raymond E., Ed.
1984-01-01
Discusses working implementations of artificial intelligence systems for chemical laboratory applications. They include expert systems for liquid chromatography, spectral analysis, instrument control of a totally computerized triple-quadrupole mass spectrometer, and the determination of the mineral constituents of a rock sample given the powder…
Lu, Yuejuan; Li, Ning; Deng, Ying; Zhao, Longshan; Guo, Xingjie; Li, Famei; Xiong, Zhili
2015-07-01
A rapid, sensitive and selective ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous determination of icariin, naringin and osthole in rat plasma. Plasma samples pretreatment involved a one-step liquid-liquid extraction with a mixture of ethyl acetate-methyl tert-butyl ether (3:1, ν/ν). The separation was performed on an ACQUITY UPLC™ BEH C18 column with a gradient mobile phase system of methanol and water. The detection was performed on a triple quadrupole tandem mass spectrometer equipped with electrospray ionization (ESI) by multiple reactions monitoring (MRM), with the transitions at m/z 513.3→366.8 (icariin), m/z 579.3→150.9 (naringin), m/z 245.1→189.0 (osthole) and m/z 237.1→194.1 (IS), respectively. A good linear response was observed over the concentration ranges of 1.06-424ng/ml, 2.10-525ng/ml and 1.05-1.05×10(3)ng/ml with lower limit of quantification (LLOQ) of 1.06, 2.10 and 1.05ng/ml for icariin, naringin and osthole, respectively. The intra- and inter-day precisions (R.S.D.) were within 14.3%, and the accuracy (R.E.) ranged from -4.1% to 4.6% at three quality control levels. The sensitive and selective method was applied to a pharmacokinetic study of icarrin, naringin and osthole in rats after oral administration of Gushudan capsule. Copyright © 2015 Elsevier B.V. All rights reserved.
Ke, Changliang; Liu, Qi; Li, Liudong; Chen, Jiewen; Wang, Xunuo; Huang, Ke
2016-09-15
Gas chromatography (GC) coupled with triple quadrupole tandem mass spectrometry (MS/MS) operated in electron ionization mode (EI) has been shown to have advantages in the trace analysis of chemical compounds. Employing the instrument, a method has been built to simultaneously determine eugenol, isoeugenol' and methyleugenol, which have been widely used as fish anesthetic, in the fish fillet. Procedure for the sample preparation was achieved by using hexane extraction followed by phenyl solid phase extraction (SPE) cleanup, which was free of such steps as rotary evaporation and nitrogen blowing by taking the volatility of eugenol and its isomers into consideration. The method was validated by conducting recovery studies on fortified fish fillet samples at four concentrations. The linearity in the range of 5-500μg·L(-1) was forced through the origin giving a coefficient of determination (r(2)) greater than 0.9982. Limits of detection (LODs) for eugenol, isoeugenol' and methyleugenol were 0.4, 1.2' and 0.2μg·kg(-1), respectively. The limits of quantification (LOQs) were 1.2, 4' and 0.7μg·kg(-1) for eugenol, isoeugenol' and methyleugenol, respectively. The recoveries for eugenol and its isomers ranged from 76.4 to 99.9% with relative standard deviations (RSD) in a range from 2.18 to 15.5%. This method is quick, simple and suitable for determining the residues of eugenol, isoeugenol and methyleugenol simultaneously in batch samples of fish fillet. Copyright © 2016 Elsevier B.V. All rights reserved.
Measurement of tamsulosin in human serum by liquid chromatography-tandem mass spectrometry.
Upreti, Rita; Homer, Natalie Z M; Naredo, Gregorio; Cobice, Diego F; Hughes, Katherine A; Stewart, Laurence H; Walker, Brian R; Andrew, Ruth
2013-07-01
A simple, sensitive and robust method to extract tamsulosin from human serum, and quantify by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and validated and is applicable as a measure of compliance in clinical research. Tamsulosin was extracted from human serum (100μL) via liquid-liquid extraction with methyl tert-butyl ether (2mL) following dilution with 0.1M ammonium hydroxide (100μL), achieving 99.9% analyte recovery. Internal standard, d9-finasteride, was synthesised in-house. Analyte and internal standard were separated on an Ascentis(®) Express C18 (100mm×3mm, 2.7μm) column using a gradient elution with mobile phases methanol and 2mM aqueous ammonium acetate (5:95, v/v). Total run-time was 6min. Tamsulosin was quantified using a triple quadrupole mass spectrometer operated in multi-reaction-monitoring (MRM) mode using positive electrospray ionisation. Mass transitions monitored for quantitation were: tamsulosin m/z 409→228 and d9-finasteride m/z 382→318, with the structural formulae of ions confirmed by Fourier transform ion cyclotron resonance mass spectrometry (within 10ppm). The limit of quantitation was 0.2ng/mL, and the method was validated in the linear range 0.2-50ng/mL with acceptable inter- and intra-assay precision and accuracy and stability suitable for routine laboratory practice. The method was successfully applied to samples taken from research volunteers in a clinical study of benign prostatic hyperplasia. Copyright © 2013 The Authors. Published by Elsevier B.V. All rights reserved.
Yang, Bixia; Wang, Lian; Luo, Chunying; Wang, Xixi; Sun, Chengjun
2017-11-01
An analytical method was developed for the simultaneous determination of 11 aminoglycoside (AG) antibiotics, including amikacin, paromomycin, dihydrostreptomycin, gentamicin C1a, hygromycin, kanamycin, netilmicin, spectinomycin, sisomicin, streptomycin, and tobramycin in honey, milk, and pork samples by LC with tandem MS and molecularly imprinted polymer (MIP) SPE. The AG antibiotics in milk and homogenated meat samples were extracted with a solution composed of 10 mmol/L potassium dihydrogen phosphate, 0.4 mmol/L EDTA-Na2, and 2% trichloroacetic acid. For honey samples, the extractant was 50 mmol/L potassium dihydrogen phosphate. The extracts were cleaned up with MIP SPE cartridges. The separation was performed on a zwitter ionic-HILIC column (50 × 2.1 mm, 3.5 μm), with the mobile phase consisting of methanol, 0.3% formic acid, and 175 mmol/L ammonium formate at 0.50 mL/min in gradient elution. A triple-quadrupole mass spectrometer equipped with an electrospray ionization source, which was operated in positive mode, was used for detection. The quantification was based on matrix-matched calibration curves. The method was applied to real samples with three different matrixes. The LODs of the method were 2-30 μg/kg and the LOQs were 7-100 μg/kg; the average recovery ranged from 78.2 to 94.8%; intraday RSDs and interday RSDs were ≤15 and ≤18%, respectively; and the absolute values of matrix effect for all AGs were RSDs ≤23%.
Tkáčiková, Soňa; Kožárová, Ivona; Mačanga, Ján; Levkut, Martin
2012-01-01
Lasalocid is a polyether ionophoric coccidiostat used for the prevention of coccidiosis in poultry at a prescribed concentration and during a certain time interval. Due to a public health concern about the presence of coccidiostat residues in poultry, the aim of the present study was to determine the levels of lasalocid residues in the edible tissues of broiler chickens (breast muscle, thigh muscle, heart, liver, gizzard, kidneys and skin/fat) fed commercially produced feed containing 100 mg kg⁻¹) of lasalocid in complete feed throughout the 5-day withdrawal period (WP). The residues were investigated by liquid chromatography coupled with electrospray ionisation (ESI) tandem mass spectrometry (MS/MS) with triple quadrupole. The limit of detection (LOD) and the limit of quantification (LOQ) of the method were 0.47 and 1.44 µg kg⁻¹, respectively. The average recovery based on the matrix-fortified calibrations for chicken tissues ranged between 79% and 98%. Lasalocid was found to accumulate in the liver, followed by the heart, skin/fat, kidneys, thigh muscle and gizzard. The lowest concentrations of lasalocid residues were found in the breast muscle. On day 5 of the WP, residue concentrations of lasalocid did not decline below the LOQ of the method, but were far below the maximum residue level (MRL) established for lasalocid in poultry from 20 to 100 µg kg⁻¹ by European Commission Regulation (EU) No. 37/2010. The results confirmed that the WP established for lasalocid is sufficient to ensure the decline of its residues in the tissues of broiler chickens to the safe residue level.
Sun, Yichun; Xue, Juan; Li, Baimei; Lin, Xiaoting; Wang, Zhibin; Jiang, Hai; Zhang, Hongwei; Wang, Qiuhong; Kuang, Haixue
2016-11-01
A rapid, sensitive, and reliable analytical ultra performance liquid chromatography with tandem mass spectrometry method was developed for the simultaneous determination of Aralia-saponin IV, 3-O-β-d-glucopyranosyl-(1→3)-β-d-glucopyranosyl-(1→3)-β-d-glucopyranosyl oleanolic acid 28-O-β-d-glucopyranoside, Aralia-saponin A and Aralia-saponin B after the oral administration of total saponin of Aralia elata leaves in rat plasma. Plasma samples were pretreated by protein precipitation with methanol. The analysis was performed on an ACQUITY UPLC HSS T3 column. The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode using an electrospray ionization source with negative ionization mode. Under the experimental conditions, the calibration curves of four analytes had good linearity values (r > 0.991). The intra- and inter-day precision values of the four analytes were ≤ 11.6%, and the accuracy was between -6.2 and 4.2%.The extraction recoveries of four triterpenoid saponins were in the range of 84.06-91.66% (RSD < 10.5%), and all values of the matrix effect were more than 90.30%. The developed analytical method was successfully applied to pharmacokinetic study on simultaneous determination of the four triterpenoid saponins in rat plasma after oral administration of total saponin of Aralia elata leaves, which helps guiding clinical usage of Aralia elata leaves. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Heal, Katherine R; Carlson, Laura Truxal; Devol, Allan H; Armbrust, E Virginia; Moffett, James W; Stahl, David A; Ingalls, Anitra E
2014-11-30
Vitamin B(12) is an essential nutrient for more than half of surveyed marine algae species, but methods for directly measuring this important cofactor in seawater are limited. Current mass spectrometry methods do not quantify all forms of B(12), potentially missing a significant portion of the B(12) pool. We present a method to measure vitamins B(1), B(2), B(6), B(7) and four forms of B(12) dissolved in seawater. The method entails solid-phase extraction, separation by ultra-performance liquid chromatography, and detection by triple-quadrupole tandem mass spectrometry using stable-isotope-labeled internal standards. We demonstrated the use of this method in the environment by analyzing B(12) concentrations at different depths in the Hood Canal, part of the Puget Sound estuarine system in Washington State. Recovery of vitamin B(12) forms during the preconcentration steps was >71% and the limits of detection were <0.275 pM in seawater. Standard addition calibration curves in three different seawater matrices were used to determine analytical response and to quantify samples from the environment. Hydroxocobalamin was the main form of B(12) in seawater at our field site. We developed a method for quantifying four forms of B(12) in seawater by liquid chromatography/mass spectrometry with the option of simultaneous analysis of vitamins B(1), B(2), B(6), and B(7). We validated the method and demonstrated its application in the field. Copyright © 2014 John Wiley & Sons, Ltd.
Zhang, Yiwei; Li, Jian; Meng, Zhiyun; Zhu, Xiaoxia; Gan, Hui; Gu, Ruolan; Wu, Zhuona; Zheng, Ying; Wei, Jinbin; Dou, Guifang
2017-06-15
17-Ethinyl-3,17-dihydroxyandrost-5-ene (EAD) is an agent designed for the treatment of acute radiation syndrome (ARS). Given its vital role played in the prevention and mitigation of ARS, the development of a sharp, sensitive and robust liquid chromatography tandem mass spectrometry (LC-MS/MS) method to monitor the metabolism of EAD in vivo was crucial. A new method was constructed and validated for the determination of EAD with the internal standard of androst-5-ene-3β,17β-diol (5-AED). The blood samples were precipitated with methanol, centrifuged, from which the supernatant was separated on UPLC with C18 column and eluted in gradient with acetonitrile and Milli-Q water both containing 0.1% formic acid (FA). Quantification was performed by a triple quadrupole mass spectrometer with electro spray ionization (ESI) in multiple reactive monitoring (MRM) positive mode. A good linearity was obtained with R>0.99 for EAD within its calibration range from 5 to 1000ngmL -1 with a lowest limit of quantification (LLOQ) of 5ngmL -1 . Inter- and intra-day accuracy and precision of three levels of quality control (QC) samples were within the range of 15%, while the LLOQ was within 20%. Samples were stable under the circumstances of the experiments. The method was simple, accurate and robust applied to determine the concentrations of EAD in Wistar rat after a single administration of EAD orally at the dose of 100mgkg -1 . Copyright © 2017 Elsevier B.V. All rights reserved.
Thappali, Satheeshmanikandan R. S.; Varanasi, Kanthikiran; Veeraraghavan, Sridhar; Arla, Rambabu; Chennupati, Sandhya; Rajamanickam, Madheswaran; Vakkalanka, Swaroop; Khagga, Mukkanti
2012-01-01
A new method for the simultaneous determination of celecoxib, erlotinib, and its active metabolite desmethyl-erlotinib (OSI-420) in rat plasma, by liquid chromatography/tandem mass spectrometry with positive/negative ion-switching electrospray ionization mode, was developed and validated. Protein precipitation with methanol was selected as the method for preparing the samples. The analytes were separated on a reverse-phase C18 column (50mm×4.6mm i.d., 3μ) using methanol: 2 mM ammonium acetate buffer, and pH 4.0 as the mobile phase at a flow rate 0.8 mL/min. Sitagliptin and Efervirenz were used as the internal standards for quantification. The determination was carried out on a Theremo Finnigan Quantam ultra triple-quadrupole mass spectrometer, operated in selected reaction monitoring (SRM) mode using the following transitions monitored simultaneously: positive m/z 394.5→278.1 for erlotinib, m/z 380.3→278.1 for desmethyl erlotinib (OSI-420), and negative m/z −380.1→ −316.3 for celecoxib. The limits of quantification (LOQs) were 1.5 ng/mL for Celecoxib, erlotinib, and OSI-420. Within- and between-day accuracy and precision of the validated method were within the acceptable limits of < 15% at all concentrations. The quantitation method was successfully applied for the simultaneous estimation of celecoxib, erlotinib, and desmethyl erlotinib in a pharmacokinetic study in Wistar rats. PMID:23008811
Irie, Kei; Shobu, Saori; Hiratsuji, Seika; Yamasaki, Yuta; Nanjo, Shigeki; Kokan, Chiyuki; Hata, Akito; Kaji, Reiko; Masago, Katsuhiro; Fujita, Shiro; Okada, Yutaka; Katakami, Nobuyuki; Fukushima, Shoji
2018-06-15
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of gefitinib in dried blood spots (DBSs). Gefitinib was extracted with methanol from DBS of 3 mm in diameter and detected using a triple quadrupole mass spectrometer. The method was validated by evaluating its precision, accuracy, selectivity, carryover, matrix effect, recovery, and stability. For clinical validation, paired finger-prick DBS and plasma concentrations were compared for 10 patients with non-small cell lung cancer (NSCLC) taking gefitinib. The calibration linear range was 37.5-2400 ng/mL (coefficient of determination [R 2 ] = 0.99), encompassing the therapeutic concentrations of gefitinib. The accuracy and precision were within 15% of the quality control (QC) concentrations of 80, 200, and 2000 ng/mL. The lower limit of quantification was determined to be 40 ng/mL. Gefitinib was stable in DBSs for up to 5 months at room temperature and -20 °C, and at 40 °C for 24 h. A good correlation was observed between the gefitinib levels measured by the DBS method and plasma concentrations (R 2 = 0.99). This method provides a simple, fast, and accurate approach to the quantitative analysis of gefitinib in finger-prick DBSs. The method would be useful for minimally invasive evaluation of the clinical gefitinib blood concentration. Copyright © 2018 Elsevier B.V. All rights reserved.
Liu, Ping; Fan, Sai; Wu, Guohua; Zhao, Rong; Liu, Wei; Zhao, Xudong
2016-05-01
A method for the simultaneous determination of 6 plant growth regulator (PGR) residues in bean sprout was developed by ultra high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). 6-Benzylaminopurine, isopentennyladenine, 4-chlorophenoxyacetic acid, 4-fluorophenoxyacetic acid, indole-3- acetic acid and indole-3-butyric acid were concerned. Bean sprout samples were extracted by acetonitrile and QuEChERS extraction kit, purified by C18 powers. After centrifugation, the sample liquids was diluted 10 times by ultrapure water. The chromatographic analysis was carried out on an waters acquity UPLC BEH C18 column( 100 mm x 2.1 mm, 1.7 microm). The analyzer confirmed and quantified by mass spectrum of triple quadrupole in the multiple reaction monitoring (MRM) mode and quantified by matrix-matched external standard method. The calibration curves showed good linearity in each range with correlation coefficients greater than 0.998. 3 levels spiked recoveries were carried out using blank bean sprout extraction as substrate, the recoveries ranged from 84.2% to 107.5%, the relative standard deviations (RSDs) ranged from 3.08% to 12.71%. The qualitative limits of detections (S/N = 3) were 0.03-3.0 microg/kg and the quantitative limits(S/N = 10) were 0.1-10.0 microg/kg for the 6 PGRs. The method is simple and easy to operate, with less organic reagent, high sensitivity and good stability. It is suitable for the detection of 6 kinds of plant growth regulators in bean sprouts.
Ma, Wen; Peng, Yan; Wang, Weihui; Bian, Qiaoxia; Wang, Nannan; Lee, David Y-W; Dai, Ronghua
2016-10-01
A fast, sensitive and reliable ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method has been developed and validated for simultaneous quantitation and pharmacokinetic study of five tanshinones (tanshinone I, tanshinone IIA, tanshinone IIB, dihydrotanshinone I, cryptotanshinone), the bio-active ingredients of Huo Luo Xiao Ling Dan (HLXLD) in rat plasma. After liquid-liquid extraction, chromatographic separation was accomplished on a Shim-pack XR-ODS column (75 × 3.0 mm, 2.2 µm particles) and eluted with a mobile phase consisting of acetonitrile-0.05% formic acid aqueous solution (80:20, v/v) at a flow rate of 0.4 mL/min, and the total run time was 7.0 min. The detection was performed on a triple quadrupole tandem mass spectrometry equipped with an electrospray ionization source in positive ionization and multiple reaction monitoring mode. The lower limits of quantification were 0.050-0.400 ng/mL for all the analytes. Linearity, precision and accuracy, the mean extraction recoveries and matrix effects all satisfied criteria for acceptance. This validated method was successfully applied to a comparative pharmacokinetic study of five bio-active components in rat plasma after oral administration of HLXLD or Salvia miltiorrhiza extract in normal and arthritic rats. The results showed that there were different pharmacokinetic characteristics among different groups. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Rodríguez-Delgado, Rosa Georgina; Figueroa-Damián, Ricardo; Domínguez-Castro, Mauricio; López-Martínez, Margarita; Flores-García, Zayra
2018-01-01
The primary strategy to avoid mother-to-child transmission of human immunodeficiency virus (HIV) through breastfeeding is administration of highly active antiretroviral therapy (HAART) to HIV-positive pregnant women. Because significant changes in the pharmacokinetics of antiretroviral (ARV) drugs occur during pregnancy, quantifying HAART and the viral load in breast milk in this population is essential. Here, we developed an analytical assay for the simultaneous quantification of four ARV drugs in breast milk using ultra-performance liquid chromatography coupled to tandem mass spectrometry. We validated this method following Mexican and international guidelines. ARV drugs. We extracted the ARV drugs from 200 μL samples of breast milk and detected these drugs in a triple quadrupole mass spectrometer with positive electrospray ionization. The validated concentration ranges (ng/mL) for zidovudine, lamivudine, lopinavir, and ritonavir were 12.5–750, 50–2500, 100–5000 and 5 to 250, respectively. Additionally, the absolute recovery percentages (and matrix effects) were 91.4 (8.39), 88.78 (28.75), 91.38 (11.77) and 89.78 (12.37), respectively. We determined that ARV drugs are stable for 24 h at 8°C and 24°C for 15 days at –80°C. This methodology had the capacity for simultaneous detection; separation; and accurate, precise quantification of ARV drugs in human breast milk samples according to Mexican standard laws and United States Food and Drug Administration guidelines. PMID:29351333
Jamalapuram, Seshulatha; Vuppala, Pradeep Kumar; Abdelazeem, Ahmed H; McCurdy, Christopher R; Avery, Bonnie A
2013-08-01
Methamphetamine abuse continues as a major problem in the USA owing to its powerful psychological addictive properties. AZ66, 3-[4-(4-cyclohexylpiperazine-1-yl)pentyl]-6-fluorobenzo[d]thiazole-2(3H)-one, an optimized sigma receptor ligand, is a promising therapeutic agent against methamphetamine. To study the in vivo pharmacokinetics of this novel sigma receptor ligand in rats, a sensitive ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed in rat plasma and validated. The developed method requires a small volume of plasma (100 μL) and a simple liquid-liquid extraction. The chromatographic separations were achieved in 3.3 min using an Acquity UPLC BEH Shield RP18 column. The mass spectrophotometric detection was carried out using a Waters Micromass Quattro MicroTM triple-quadrupole system. Multiple reaction monitoring was used for the quantitation with transitions m/z 406 → m/z 181 for AZ66 and m/z 448 → m/z 285 for aripiprazole. The method was validated over a concentration range of 1-3500 ng/mL and the lower limit of quantitation was determined to be 1 ng/mL. Validation of the assay demonstrated that the developed UPLC/MS/MS method was sensitive, accurate and selective for the determination of AZ66 in rat plasma. The present method has been successfully applied to an i.v. pharmacokinetic study in Sprague-Dawley rats. Copyright © 2013 John Wiley & Sons, Ltd.
Lozano, Ana; Rajski, Łukasz; Uclés, Samanta; Belmonte-Valles, Noelia; Mezcua, Milagros; Fernández-Alba, Amadeo R
2014-01-01
Two sorbents containing ZrO₂ (Z-Sep and Z-Sep+) were tested as a d-SPE clean-up in combination with the QuEChERS and ethyl acetate multiresidue method in the pesticide residues extraction in avocado. All extracts were analysed using gas chromatography coupled with a triple quadrupole mass spectrometer working in multi-reaction monitoring mode. GC QToF was used to compare the amount of matrix compounds present in the final extracts, prepared according to different protocols. The highest number of pesticides with acceptable recoveries and the lowest amount of coextracted matrix compounds were provided by QuEChERS with Z-Sep. Subsequently, this method was fully validated in avocado and almonds. Validation studies were carried out according to DG Sanco guidelines including: the evaluation of recoveries at two levels (10 and 50 μg/kg), limit of quantitation, linearity, matrix effects, as well as interday and intraday precision. In avocado, 166 pesticides were fully validated compared to 119 in almonds. The method was operated satisfactorily in routine analysis and was applied to real samples. © 2013 Published by Elsevier B.V.
Review of Software Tools for Design and Analysis of Large scale MRM Proteomic Datasets
Colangelo, Christopher M.; Chung, Lisa; Bruce, Can; Cheung, Kei-Hoi
2013-01-01
Selective or Multiple Reaction monitoring (SRM/MRM) is a liquid-chromatography (LC)/tandem-mass spectrometry (MS/MS) method that enables the quantitation of specific proteins in a sample by analyzing precursor ions and the fragment ions of their selected tryptic peptides. Instrumentation software has advanced to the point that thousands of transitions (pairs of primary and secondary m/z values) can be measured in a triple quadrupole instrument coupled to an LC, by a well-designed scheduling and selection of m/z windows. The design of a good MRM assay relies on the availability of peptide spectra from previous discovery-phase LC-MS/MS studies. The tedious aspect of manually developing and processing MRM assays involving thousands of transitions has spurred to development of software tools to automate this process. Software packages have been developed for project management, assay development, assay validation, data export, peak integration, quality assessment, and biostatistical analysis. No single tool provides a complete end-to-end solution, thus this article reviews the current state and discusses future directions of these software tools in order to enable researchers to combine these tools for a comprehensive targeted proteomics workflow. PMID:23702368
Yan, Ying; Zhao, Hui; Chen, Cuihua; Zou, Lisi; Liu, Xunhong; Chai, Chuan; Wang, Chengcheng; Shi, Jingjing; Chen, Shuyu
2018-03-13
Eucommia ulmoides Oilv. (EU), also called Du-zhong, is a classical traditional Chinese medicine. Its bark, leaf, and male flower are all used for medicinal purposes, called Eucommiae Cortex (EC), Eucommiae Folium (EF), and Eucommiae Flos Male (EFM). In order to study the difference in synthesis and the accumulation of metabolites in different parts of EU, a reliable method based on ultra-fast liquid chromatography tandem triple quadrupole mass spectrometry (UFLC-QTRAP-MS/MS) was developed for the simultaneous determination of a total of 21 constituents, including two lignans, 6 iridoids, 6 penylpropanoids, 6 flavonoids, and one phenol in the samples (EC, EF, and EFM). Furthermore, principal component analysis (PCA) was performed to evaluate and classify the samples according to the contents of these 21 constituents. All of the results demonstrated that the chemical compositions in EC, EF, and EFM were significantly different and the differential constituents (i.e., aucubin, geniposidic acid, chlorogenic acid, pinoresinol-di- O -β-d-glucopyranoside, geniposide, cryptochlorogenic acid, rutin, and quercetin) were remarkably associated with sample classifications. The research will provide the basic information for revealing the laws of metabolite accumulation in EC, EF, and EFM from the same origin.
Crestoni, Maria Elisa; Chiavarino, Barbara; Guglielmo, Stefano; Lilla, Valentina; Fornarini, Simonetta
2013-01-01
Aspirin (acetylsalicylic acid, ASA) is the most popular non-steroidal anti-inflammatory drug. However, due to its action on cyclooxygenase and its acid nature, aspirin is associated with adverse gastrointestinal effects. In an effort to minimize these side effects, NO-donor and H2S-donor ASA co-drugs have been designed and tested. Their mass spectrometric behavior is now analyzed and reported. Positive ions were obtained by electrospray ionization involving protonation or alkali metal attachment. Their dissociation processes have been studied by collision induced dissociation in a triple quadrupole instrument. High mass accuracy measurements have been recorded on a Fourier transform ion cyclotron resonance mass spectrometer. The protonated molecules dissociate by an exclusive or largely prevailing path leading to acetyloxy-substituted benzoyl cation, namely an ASA unit. The process is reminiscent of the enzymatic hydrolysis, releasing intact ASA to a large extent. Only at higher collision energy does the formal ketene loss disrupt the ASA moiety. The gas phase chemistry of protonated ASA-releasing drugs develops along elementary dissociation steps analogous to the reactive processes in complex biological environments. This notion may provide a tool for preliminary testing of new compounds.
A Tiered Analytical Approach for Investigating Poor Quality Emergency Contraceptives
Monge, María Eugenia; Dwivedi, Prabha; Zhou, Manshui; Payne, Michael; Harris, Chris; House, Blaine; Juggins, Yvonne; Cizmarik, Peter; Newton, Paul N.; Fernández, Facundo M.; Jenkins, David
2014-01-01
Reproductive health has been deleteriously affected by poor quality medicines. Emergency contraceptive pills (ECPs) are an important birth control method that women can use after unprotected coitus for reducing the risk of pregnancy. In response to the detection of poor quality ECPs commercially available in the Peruvian market we developed a tiered multi-platform analytical strategy. In a survey to assess ECP medicine quality in Peru, 7 out of 25 different batches showed inadequate release of levonorgestrel by dissolution testing or improper amounts of active ingredient. One batch was found to contain a wrong active ingredient, with no detectable levonorgestrel. By combining ultrahigh performance liquid chromatography-ion mobility spectrometry-mass spectrometry (UHPLC-IMS-MS) and direct analysis in real time MS (DART-MS) the unknown compound was identified as the antibiotic sulfamethoxazole. Quantitation by UHPLC-triple quadrupole tandem MS (QqQ-MS/MS) indicated that the wrong ingredient was present in the ECP sample at levels which could have significant physiological effects. Further chemical characterization of the poor quality ECP samples included the identification of the excipients by 2D Diffusion-Ordered Nuclear Magnetic Resonance Spectroscopy (DOSY 1H NMR) indicating the presence of lactose and magnesium stearate. PMID:24748219
Alshogran, Osama Y.; Ocque, Andrew J.; Leblond, François A.; Pichette, Vincent; Nolin, Thomas D.
2016-01-01
A simple and rapid liquid chromatographic–tandem mass spectrometric method has been developed and validated for the enantiospecific determination of R- and S-warfarin in human urine. Warfarin enantiomers were extracted from urine using methyl tert-butyl ether. Chromatographic separation of warfarin enantiomers and the internal standard d5-warfarin was achieved using a Astec Chirobiotic V column with gradient mobile phase at a flow rate of 400 µL/min over 10 min. Detection was performed on a TSQ Quantum Ultra triple quadrupole mass spectrometer equipped with a heated electrospray ionization source. Analytes were detected in negative ionization mode using selected reaction monitoring. Calibration curves were linear with a correlation coefficient of ≥0.996 for both enantiomers over a concentration range of 5–500 ng/mL. The intra- and interday accuracy and precision for both analytes were within ±9.0%. Excellent extraction efficiency and negligible matrix effects were observed. The applicability of the method was demonstrated by successful measurement of warfarin enantiomers in urine of patients with kidney disease. The method is simple, accurate and reproducible and is currently being used to support warfarin pharmacokinetic studies. PMID:26657732
Bioactivation of bisphenol A and its analogs (BPF, BPAF, BPZ and DMBPA) in human liver microsomes.
Schmidt, Jan; Kotnik, Petra; Trontelj, Jurij; Knez, Željko; Mašič, Lucija Peterlin
2013-06-01
Bisphenol A analogs are a class of chemicals known as diphenylmethanes, which contain two benzene rings separated by one central carbon atom, usually with a para-hydroxy group on both benzene rings. Bisphenol A (BPA) can induce an uterotrophic response in immature CD-1 mice and elicits estrogenic responses in many other experimental systems. Besides highlighting endocrine effects, a number of metabolic studies provide strong support for the idea that reactive species of BPA are formed in vitro and in vivo that can form covalent adducts with nucleophilic macromolecules and/or produce oxidative stress. We used a liquid chromatography with a triple quadrupole tandem mass spectrometry (LC-MS/MS) for the detection of metabolites and glutathione conjugates of BPA and its analogs (BPF, BPAF, BPZ and DMBPA) in human liver microsomes (HLM) or with recombinant CYP isozymes in the presence of NADPH and GSH as a trapping agent. We have confirmed that BPA and its structural analogs form hydroxylated metabolites and electrophilic species during bioactivation in HLM and CYP isozymes. These results provided important mechanistic insight into the metabolic fate of BPA structural analogs in vitro. Copyright © 2013 Elsevier Ltd. All rights reserved.
Mata, Dani C; Davis, John F; Figueroa, Ariana K; Stanford, Mary June
2016-01-01
An ultra performance liquid chromatography triple quadrupole mass spectrometry (LC-MS-MS) method for the quantification of 14 benzodiazepines and three sedative hypnotics is presented. The fast and inexpensive assay was developed for California's Orange County Crime Lab for use in antemortem (AM) and postmortem casework. The drugs were rapidly cleaned up from AM blood, postmortem blood, urine, liver, brain and stomach contents using DPX(®) Weak Anion Exchange (DPX WAX) tips fitted on a pneumatic extractor, which can process up to 48 samples at one time. Assay performance was determined for validation based on recommendations by the Scientific Working Group for Forensic Toxicology for linearity, limit of quantitation, limit of detection, bias, precision (within run and between run), dilution integrity, carry-over, selectivity, recovery, ion suppression and extracted sample stability. Linearity was verified using the therapeutic and toxic ranges of all 17 analytes. Final verification of the method was confirmed by four analysts using 20 blind matrix matched samples. All results were within 20% of each other and the expected value. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Czech, T; Bonilla, N Barco; Gambus, F; González, R Romero; Marín-Sáez, J; Vidal, J L Martínez; Frenich, A Garrido
2016-07-01
A quick, easy, cheap, effective, rugged and safe (QuEChERS)-based extraction method has been optimized for the determination of pentachlorophenol, 4-tertoctylphenol and 4-nonylphenol in river sediments. The extraction method was followed by gas chromatography-triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS) analysis, which ensures the reliable identification of the target compounds. The proposed method has been validated allowing the successful determination of the selected compounds, with recoveries ranging from 72 to 96%, when three concentration levels were evaluated (10, 50 and 100μgkg(-1)) and inter-day and intra-day precision, expressed as relative standard deviation (RSD), were lower than 20%. The method showed limits of detection (LODs) and limits of quantification (LOQs) ranging from 0.1 to 2.0μgkg(-1) and from 0.5 to 5.0μgkg(-1), respectively. Finally, 25 real samples from Poland have been analyzed, and only 4-tertoctylphenol was detected at concentrations up to 8.9μgkg(-1) of soil dry weight. Copyright © 2016 Elsevier B.V. All rights reserved.
Chen, Xiaocheng; Cao, Gang; Jiang, Jianping
2014-01-01
Objective: The present study examined the pharmacokinetic profiles of two iridoid glycosides named morroniside and loganin in rat plasma after oral administration of crude and processed Cornus officinals. Materials and Methods: A rapid, selective and specific high-performance liquid chromatography/electrospray ionization tandem mass spectrometry with multiple reactions monitoring mode was developed to simultaneously investigate the pharmacokinetic profiles of morroniside and loganin in rat plasma after oral administration of crude C. officinals and its jiuzhipin. Results: The morroniside and loganin in crude and processed C. officinals could be simultaneously determined within 7.4 min. Linear calibration curves were obtained over the concentration ranges of 45.45-4800 ng/mL for all the analytes. The intra-and inter-day precisions relative standard deviation was lesser than 2.84% and 4.12%, respectively. Conclusion: The pharmacokinetic parameters of two iridoid glucosides were also compared systematically between crude and processed C. officinals. This paper provides the theoretical proofs for further explaining the processing mechanism of Traditional Chinese Medicines. PMID:24914290
Pastor, Victoria; Vicent, Cristian; Cerezo, Miguel; Mauch-Mani, Brigitte; Dean, John; Flors, Victor
2012-04-01
An approach for the detection and characterization of SA derivatives in plant samples is presented based on liquid chromatography coupled to electrospray ionization (ESI) tandem mass spectrometric techniques. Precursor ion scan methods using an ESI triple quadrupole spectrometer for samples from plants challenged with the virulent Pseudomonas syringae pv tomato DC3000 allowed us to detect two potential SA derivatives. The criterion used to consider a potential SA derivative is based on the detection of analytes in the precursor ion scan chromatogram upon selecting m/z 137 and m/z 93 that correspond to the salicylate and its main product ion, respectively. Product ion spectra of the newly-detected analytes as well as accurate m/z determinations using an ESI Q-time-of-flight instrument were registered as means of characterization and strongly suggest that glucosylated forms of SA at the carboxylic and at the phenol functional groups are present in plant samples. The specific synthesis and subsequent chromatography of salicylic glucosyl ester (SGE) and glucosyl salicylate (SAG) standards confirmed the chemical identity of both peaks that were obtained applying different tandem mass spectrometric techniques and accurate m/z determinations. A multiple reaction monitoring method has been developed and applied to plant samples. The advantages of this LC-ESI-MS/MS methods with respect to the traditional analysis of glucosyl conjugates are also discussed. Preliminary results revealed that SA and the glucosyl conjugates are accumulated in Arabidopsis thaliana in a time dependent manner, accordingly to the up-regulation of SA-dependent defenses following P. syringae infection. This technique applied to plant hormones or fragment ions may be useful to obtain chemical family members of plant metabolites and help identify their contribution in the signaling of plant defenses. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Pichini, Simona; Marchei, Emilia; Martello, Simona; Gottardi, Massimo; Pellegrini, Manuela; Svaizer, Fiorenza; Lotti, Andrea; Chiarotti, Marcello; Pacifici, Roberta
2015-04-01
We developed and validated an ultra-high-pressure liquid chromatography-tandem mass spectrometry method to identify and quantify 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide in hair of cannabis consumers. After hair washing with methyl alcohol and diethyl ether and subsequent addition of amiodarone as internal standard hair samples were treated with 500 μl VMA-T M3 buffer reagent for 1 h at 100 °C. After cooling, 10 μl VMA-T M3 extract were injected into chromatographic system. Chromatographic separation was carried out on a reversed phase column using a linear gradient elution with two solvents: 5 mM ammonium formate pH 3.0 (solvent A) and 0.1% formic acid in acetonitrile (solvent B). The flow rate was kept constant at 0.4 ml/min during the analysis. The separated analytes were detected with a triple quadrupole mass spectrometer operated in multiple reaction monitoring mode via positive electrospray ionization. Linear calibration curves were obtained for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide with correlation coefficients (r(2)) of 0.99 and a limit of quantification of 0.25 pg/mg hair. Analytical recovery was between 79.6% and 100.7% and intra- and inter-assay imprecision and inaccuracy were always lower than 15%. Ultra-high-pressure liquid chromatography-tandem mass spectrometry analysis of 20 different hair samples of cannabis consumers disclosed the presence of 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide in the range of 0.5-8.6 pg/mg hair. These data provided a good start to consider 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid glucuronide as alternative hair biomarker of cannabis consumption. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Cho, Sung E; Kim, Sollip; Kim, Young D; Lee, Hyojung; Seo, Dong H; Song, Junghan; Um, Tae H; Cho, Chong R; Kim, Nam H; Hwang, Jong H
2017-09-01
Background We evaluated the performance of ultra-performance liquid chromatography-tandem mass spectrometry to measure serum 3-epi-25-hydroxyvitamin D 3 , 25-hydroxyvitamin D 3 and 25-hydroxyvitamin D 2 concentrations in 519 infant, paediatric and adolescent serum samples in Korea. Methods We used a Kinetex XB-C18 column and isocratic methanol/water (77.5/22.5, v/v) with 0.025% (v/v) high-performance liquid chromatography solvent additive flowing at 0.25 mL/min, yielding an 11 min/sample run time. A TQD triple quadrupole mass spectrometer in electrospray ionization positive ion mode with multiple reaction monitoring transition via an MSMS vitamin D kit was used to evaluate precision, carryover, ion suppression and linearity. Samples were prepared using the 4-phenyl-1,2,4-triazoline-3,5-dione derivatization method. Results Intra- and inter-run precisions were 1.23-13.28% and 1.02-10.08%, respectively. Group carryovers were -0.27% and 0.10%, respectively. There was no ion suppression. The calibration curve showed good linearity from calibrator Level 1 (11.75 nmol/L) to 6 (375 nmol/L) with R 2 > 0.9999. The 3-epi-25-hydroxyvitamin D 3 and 25-hydroxyvitamin D 3 peaks were clearly separated in the extracted ion chromatogram. Infant serum samples 3-epi-25-hydroxyvitamin D 3 concentrations were significantly higher than paediatric and adolescent concentrations. Conclusions The ultra-performance liquid chromatography-tandem mass spectrometry assay performed acceptably, clearly separating 3-epi-25-hydroxyvitamin D 3 from 25-hydroxyvitamin D 3 . High 3-epi-25-hydroxyvitamin D 3 concentrations were observed in infant but not in paediatric and adolescent serum samples.
Gentili, Alessandra; Caretti, Fulvia
2011-02-04
The feasibility of using reversed-phase liquid chromatography/diode array/tandem mass spectrometry (LC-DAD-MS/MS) for a rapid and comprehensive profiling of fat soluble vitamins and pigments in some foods of plant origin (maize flour, green and golden kiwi) was evaluated. The instrumental approach was planned for obtaining two main outcomes within the same chromatographic run: (i) the quantitative analysis of ten target analytes, whose standards are commercially available; (ii) the screening of pigments occurring in the selected matrices. The quantitative analysis was performed simultaneously for four carotenoids (lutein, zeaxanthin, β-cryptoxanthin, and β-carotene) and six compounds with fat-soluble activity (α-tocopherol, δ-tocopherol, γ-tocopherol, ergocalciferol, phylloquinone and menaquinone-4), separated on a C30 reversed-phase column and detected by atmospheric pressure chemical ionization (APCI) tandem mass spectrometry, operating in Selected Reaction Monitoring (SRM) mode. Extraction procedure was based on matrix solid-phase dispersion with recoveries of all compounds under study exceeding 78 and 60% from maize flour and kiwi, respectively. The method intra-day precision ranged between 3 and 7%, while the inter-day one was below 12%. The mild isolation conditions precluded artefacts creation, such as cis-isomerization phenomena for carotenoids. During the quantitative LC-SRM determination of the ten target analytes, the identification power of the diode array detector joined to that of the triple quadrupole (QqQ) allowed the tentatively identification of several pigments (chlorophylls and carotenoids), without the aid of standards, on the basis of: (i) the UV-vis spectra recorded in the range of 200-700nm; (ii) the expected retention time; (iii) the two SRM transitions, chosen for the target carotenoids but also common to many of isomeric carotenoids occurring in the selected foods. Copyright © 2010 Elsevier B.V. All rights reserved.
The Assessment of Selectivity in Different Quadrupole-Orbitrap Mass Spectrometry Acquisition Modes
NASA Astrophysics Data System (ADS)
Berendsen, Bjorn J. A.; Wegh, Robin S.; Meijer, Thijs; Nielen, Michel W. F.
2015-02-01
Selectivity of the confirmation of identity in liquid chromatography (tandem) mass spectrometry using Q-Orbitrap instrumentation was assessed using different acquisition modes based on a representative experimental data set constructed from 108 samples, including six different matrix extracts and containing over 100 analytes each. Single stage full scan, all ion fragmentation, and product ion scanning were applied. By generating reconstructed ion chromatograms using unit mass window in targeted MS2, selected reaction monitoring (SRM), regularly applied using triple-quadrupole instruments, was mimicked. This facilitated the comparison of single stage full scan, all ion fragmentation, (mimicked) SRM, and product ion scanning applying a mass window down to 1 ppm. Single factor Analysis of Variance was carried out on the variance (s2) of the mass error to determine which factors and interactions are significant parameters with respect to selectivity. We conclude that selectivity is related to the target compound (mainly the mass defect), the matrix, sample clean-up, concentration, and mass resolution. Selectivity of the different instrumental configurations was quantified by counting the number of interfering peaks observed in the chromatograms. We conclude that precursor ion selection significantly contributes to selectivity: monitoring of a single product ion at high mass accuracy with a 1 Da precursor ion window proved to be equally selective or better to monitoring two transition products in mimicked SRM. In contrast, monitoring a single fragment in all ion fragmentation mode results in significantly lower selectivity versus mimicked SRM. After a thorough inter-laboratory evaluation study, the results of this study can be used for a critical reassessment of the current identification points system and contribute to the next generation of evidence-based and robust performance criteria in residue analysis and sports doping.
Egom, Emmanuel E.; Fitzgerald, Ross; Canning, Rebecca; Pharithi, Rebabonye B.; Murphy, Colin; Maher, Vincent
2017-01-01
Evidence suggests that high-density lipoprotein (HDL) components distinct from cholesterol, such as sphingosine-1-phosphate (S1P), may account for the anti-atherothrombotic effects attributed to this lipoprotein. The current method for the determination of plasma levels of S1P as well as levels associated with HDL particles is still cumbersome an assay method to be worldwide practical. Recently, a simplified protocol based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the sensitive and specific quantification of plasma levels of S1P with good accuracy has been reported. This work utilized a triple quadrupole (QqQ)-based LC-MS/MS system. Here we adapt that method for the determination of plasma levels of S1P using a quadrupole time of flight (Q-Tof) based LC-MS system. Calibration curves were linear in the range of 0.05 to 2 µM. The lower limit of quantification (LOQ) was 0.05 µM. The concentration of S1P in human plasma was determined to be 1 ± 0.09 µM (n = 6). The average accuracy over the stated range of the method was found to be 100 ± 5.9% with precision at the LOQ better than 10% when predicting the calibration standards. The concentration of plasma S1P in the prepared samples was stable for 24 h at room temperature. We have demonstrated the quantification of plasma S1P using Q-Tof based LC-MS with very good sensitivity, accuracy, and precision that can used for future studies in this field. PMID:28820460
Qian, Mingrong; Zhang, Hu; Wu, Liqin; Jin, Nuo; Wang, Jianmei; Jiang, Kezhi
2015-01-01
A sensitive gas chromatographic-triple quadrupole mass spectrometric (GC-QqQ MS) analytical method, for the determination of zearalenone and its five derivatives in edible vegetable oil, was developed. After the vegetable oil samples were prepared using gel permeation chromatography, the eluent was collected, evaporated and dried with nitrogen gas. The residue was silylated with N,O-bis-trimethylsilyltrifluoroacetamide, containing 1% trimethylchlorosilane. GC-QqQ MS was performed in the reaction-monitoring mode to confirm and quantify mycotoxins in vegetable oil. The limits of quantitation were 0.03-0.2 μg kg(-1) for the six mycotoxins. The average recoveries, measured at 2, 20 and 200 μg kg(-1), were in the range 80.3-96.5%. Zearalenone was detected in the range 5.2-184.6 μg kg(-1) in nine maize oils and at 40.7 μg kg(-1) in a rapeseed oil from the local market. Copyright © 2014 Elsevier Ltd. All rights reserved.
Yang, Bo; Liu, Zhirui; Wang, Qian; Xia, Peiyuan
2018-03-01
During the course of decoction, the components of herbal formula interact with each other, such that chemical extraction characteristics are altered. The crude drugs, Lilium brownii (Baihe) and Rhizoma Anemarrhenae (Zhimu), are the herbal constituents of Baihe Zhimu decoction, a traditional herbal formula. To investigate the chemical interaction between Baihe and Zhimu when decocting together, eight marker components in Baihe Zhimu decoction were simultaneously characterized and quantified in one run by a hybrid triple quadrupole linear ion trap mass spectrometer in the multiple reactions monitoring-information dependent acquisition-enhanced product ion mode. The results showed that Zhimu significantly suppressed the extraction of phenolic glycosides (the components from Baihe) when co-decocting, and Baihe clearly suppressed the extraction of xanthones and steroidal saponins (the components from Zhimu). Overall, the presently developed method would be a preferred candidate for the investigation of the chemical interaction between herbal medicines. Copyright © 2017 John Wiley & Sons, Ltd.
Gosetti, Fabio; Chiuminatto, Ugo; Mazzucco, Eleonora; Calabrese, Giorgio; Gennaro, Maria Carla; Marengo, Emilio
2013-01-15
The study deals with the identification of the degradation products formed by simulated sunlight photoirradiation in a commercial beverage that contains Allura Red AC dye. An UHPLC-MS/MS method, that makes use of hybrid triple quadrupole/linear ion trap, was developed. In the identification step the software tool information dependent acquisition (IDA) was used to automatically obtain information about the species present and to build a multiple reaction monitoring (MRM) method with the MS/MS fragmentation pattern of the species considered. The results indicate that the identified degradation products are formed from side-reactions and/or interactions among the dye and other ingredients present in the beverage (ascorbic acid, citric acid, sucrose, aromas, strawberry juice, and extract of chamomile flowers). The presence of aromatic amine or amide functionalities in the chemical structures proposed for the degradation products might suggest potential hazards to consumer health. Copyright © 2012 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Chenchen; Lee, Cheng S.; Smith, Richard D.
2012-11-10
We demonstrate the direct coupling of transient capillary isotachophoresis/ capillary zone electrophoresis (CITP/CZE) with a high sensitivity triple quadrupole mass spectrometer operating in selected reaction monitoring (SRM) mode for sample quantitation. The capability of CITP/CZE for in situ sample enrichment and separation has been shown to significantly improve the analytical figures of merit. A linear dynamic range spanning more than 4 orders of magnitude was observed. An average signal-to-noise ratio (S/N) of 49.6 was observed for 50 attomoles of targeted peptide in the presence of a complex and much more abundant bovine serum albumin (BSA) digest products. A correlation ofmore » variation (CV) less than 10 % for peak area was measured from triplicate sample analyses at 50 pM peptide concentration, showing good reproducibility of this online CITP/CZE-SRM mass spectrometry (MS) platform, and with limit of quantitation (LOQ) demonstrated to be well below 50 pM.« less
Sun, Yongming; Xia, Biqi; Chen, Xiangzhun; Duanmu, Chuansong; Li, Denghao; Han, Chao
2015-01-01
The identification and quantification of four anthocyanins (cyanidin-3-O-glucoside, peonidin-3-O-glucoside, delphinidin-3-O-glucoside, and malvidin-3-O-glucoside) in red grape wine were carried out by hydrophilic interaction liquid chromatography/triple quadrupole linear ion trap MS (HILIC/QTrap-MS/MS). Samples were diluted directly and separated on a Merck ZIC HILIC column with 20 mM ammonium acetate solution-acetonitrile mobile phase. Quantitative data acquisition was carried out in the multiple reaction monitoring mode. Additional identification and confirmation of target compounds were performed using the enhanced product ion mode of the linear ion trap. The LOQs were in the range 0.05-1.0 ng/mL. The average recoveries were in the range 94.6 to 104.5%. The HILIC/QTrap-MS/MS platform offers the best sensitivity and specificity for characterization and quantitative determination of the four anthocyanins in red grape wines and fulfills the quality criteria for routine laboratory application.
Yan, Yongqiu; Lu, Yu; Jiang, Shiping; Jiang, Yu; Tong, Yingpeng; Zuo, Limin; Yang, Jun; Gong, Feng; Zhang, Ling; Wang, Ping
2018-01-01
Noni juice has been extensively used as folk medicine for the treatment of arthritis, infections, analgesic, colds, cancers, and diabetes by Polynesians for many years. Due to the lack of standard scientific evaluation methods, various kinds of commercial Noni juice with different quality and price were available on the market. To establish a sensitive, reliable, and accurate high-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometry (HPLC-ESI-MS/MS) method for separation, identification, and simultaneous quantitative analysis of bioactive constituents in Noni juice. The analytes and eight batches of commercially available samples from different origins were separated and analyzed by the HPLC-ESI-MS/MS method on an Agilent ZORBAX SB-C 18 (150 mm × 4.6 mm i.d., 5 μm) column using a gradient elution of acetonitrile-methanol-0.05% glacial acetic acid in water (v/v) at a constant flow rate of 0.5 mL/min. Seven components were identification and all of the assay parameters were within the required limits. Components were within the correlation coefficient values ( R 2 ≥ 0.9993) at the concentration ranges tested. The precision of the assay method was <0.91% and the repeatability between 1.36% and 3.31%. The accuracy varied from 96.40% to 103.02% and the relative standard deviations of stability were <3.91%. Samples from the same origin showed similar content while different origins showed significant different result. The developed methods would provide a reliable basis and be useful in the establishment of a rational quality control standard of Noni juice. Separation, identification, and simultaneous quantitative analysis method of seven bioactive constituents in Noni juice is originally developed by high-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometryThe presented method was successfully applied to the quality control of eight batches of commercially available samples of Noni juiceThis method is simple, sensitive, reliable, accurate, and efficient method with strong specificity, good precision, and high recovery rate and provides a reliable basis for quality control of Noni juice. Abbreviations used: HPLC-ESI-MS/MS: High-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometry, LOD: Limit of detection, LOQ: Limit of quantitation, S/N: Signal-to-noise ratio, RSD: Relative standard deviations, DP: Declustering potential, CE: Collision energy, MRM: Multiple reaction monitoring, RT: Retention time.
Yan, Yongqiu; Lu, Yu; Jiang, Shiping; Jiang, Yu; Tong, Yingpeng; Zuo, Limin; Yang, Jun; Gong, Feng; Zhang, Ling; Wang, Ping
2018-01-01
Background: Noni juice has been extensively used as folk medicine for the treatment of arthritis, infections, analgesic, colds, cancers, and diabetes by Polynesians for many years. Due to the lack of standard scientific evaluation methods, various kinds of commercial Noni juice with different quality and price were available on the market. Objective: To establish a sensitive, reliable, and accurate high-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometry (HPLC-ESI-MS/MS) method for separation, identification, and simultaneous quantitative analysis of bioactive constituents in Noni juice. Materials and Methods: The analytes and eight batches of commercially available samples from different origins were separated and analyzed by the HPLC-ESI-MS/MS method on an Agilent ZORBAX SB-C18 (150 mm × 4.6 mm i.d., 5 μm) column using a gradient elution of acetonitrile-methanol-0.05% glacial acetic acid in water (v/v) at a constant flow rate of 0.5 mL/min. Results: Seven components were identification and all of the assay parameters were within the required limits. Components were within the correlation coefficient values (R2 ≥ 0.9993) at the concentration ranges tested. The precision of the assay method was <0.91% and the repeatability between 1.36% and 3.31%. The accuracy varied from 96.40% to 103.02% and the relative standard deviations of stability were <3.91%. Samples from the same origin showed similar content while different origins showed significant different result. Conclusions: The developed methods would provide a reliable basis and be useful in the establishment of a rational quality control standard of Noni juice. SUMMARY Separation, identification, and simultaneous quantitative analysis method of seven bioactive constituents in Noni juice is originally developed by high-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometryThe presented method was successfully applied to the quality control of eight batches of commercially available samples of Noni juiceThis method is simple, sensitive, reliable, accurate, and efficient method with strong specificity, good precision, and high recovery rate and provides a reliable basis for quality control of Noni juice. Abbreviations used: HPLC-ESI-MS/MS: High-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometry, LOD: Limit of detection, LOQ: Limit of quantitation, S/N: Signal-to-noise ratio, RSD: Relative standard deviations, DP: Declustering potential, CE: Collision energy, MRM: Multiple reaction monitoring, RT: Retention time. PMID:29576704
Dong, Xinwen; Zhang, Yunbo; Dong, Jin; Zhao, Yue; Guo, Jipeng; Wang, Zhanju; Liu, Mingqi; Na, Xiaolin; Wang, Cheng
2017-07-01
Di(2-ethylhexyl) phthalate (DEHP) is an omnipresent environmental chemical with widespread nonoccupational human exposure through multiple ways. Although considerable efforts have been invested to investigate mechanisms of DEHP toxicity, the key metabolic biomarkers of DEHP toxicity remain to be identified. The aim of this study was to assess the urinary metabonomics of dietary DEHP in rats using the technique of ultra-performance liquid chromatography quadrupole time-of-flight tandem mass spectrometry (UPLC/Q-TOF-MS). Fourteen female Wistar rats were divided into two groups and given increasing dietary doses of DEHP for 30 consecutive days. The urinary metabolite profile was studied using ultra-performance liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry. Principal component analysis (PCA) and partial least squares-discriminant analysis (PLS-DA) enabled clusters to be clearly separated. Eleven principal urinary metabolites were identified as contributing to the clusters. The clusters in the positive electrospray ionization (ESI) mode were xanthurenic acid, kynurenic acid, nonate, N6-methyladenosine, and L-isoleucyl-L-proline. The clusters in the negative ESI mode were hippuric acid, tetrahydrocortisol, citric acid, phenylpropionylglycine, cPA(18:2(9Z, 12Z)/0:0), and LysoPC(14:1(9Z)). The urinary metabonomic changes indicated that exposure to dietary DEHP can affect energy-related metabolism, liver and renal function, fatty acid metabolism, and cause DNA damage in rats. The findings of this study on the urinary metabolites and metabolic pathways of DEHP may form the basis for future studies on the mechanisms of toxicity of this commonly found environmental chemical.
Binkhorst, Lisette; Mathijssen, Ron H J; Ghobadi Moghaddam-Helmantel, Inge M; de Bruijn, Peter; van Gelder, Teun; Wiemer, Erik A C; Loos, Walter J
2011-12-15
In view of future pharmacokinetic studies, a highly sensitive ultra performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS) method has been developed for the simultaneous quantification of tamoxifen and three of its main phase I metabolites in human lithium heparinized plasma. The analytical method has been thoroughly validated in agreement with FDA recommendations. Plasma samples of 200 μl were purified by liquid-liquid extraction with 1 ml n-hexane/isopropanol, after deproteination through addition of 50 μl acetone and 50 μl deuterated internal standards in acetonitrile. Tamoxifen, N-desmethyl-tamoxifen, 4-hydroxy-tamoxifen and endoxifen were chromatographically separated on an Acquity UPLC(®) BEH C18 1.7 μm 2.1 mm×100 mm column eluted at a flow-rate of 0.300 ml/min on a gradient of 0.2mM ammonium formate and acetonitrile, both acidified with 0.1% formic acid. The overall run time of the method was 10 min, with elution times of 2.9, 3.0, 4.1 and 4.2 min for endoxifen, 4-hydroxy-tamoxifen, N-desmethyl-tamoxifen and tamoxifen, respectively. Tamoxifen and its metabolites were quantified by triple-quadrupole mass spectrometry in the positive ion electrospray ionization mode. The multiple reaction monitoring transitions were set at 372>72 (m/z) for tamoxifen, 358>58 (m/z) for N-desmethyl-tamoxifen, 388>72 (m/z) for 4-hydroxy-tamoxifen and 374>58 (m/z) for endoxifen. The analytical method was highly sensitive with the lower limit of quantification validated at 5.00 nM for tamoxifen and N-desmethyl-tamoxifen and 0.500 nM for 4-hydroxy-tamoxifen and endoxifen, which is equivalent to 1.86, 1.78, 0.194 and 0.187 ng/ml for tamoxifen, N-desmethyl-tamoxifen, 4-hydroxy-tamoxifen and endoxifen, respectively. The method was also precise and accurate, with within-run and between-run precisions within 12.0% and accuracy ranging from 89.5 to 105.3%. The method has been applied to samples from a clinical study and cross-validated with a validated LC-MS/MS method in serum. Copyright © 2011 Elsevier B.V. All rights reserved.
Patel, Katan; Fussell, Richard J; Hetmanski, Mike; Goodall, David M; Keely, Brendan J
2005-03-18
A gas chromatography-tandem quadrupole mass spectrometry multi-residue method for the analysis of 19 organochlorine pesticides in fats and oils has been developed. Gel permeation chromatography was employed to remove lipid material prior to GC-MS/MS analysis. Average recoveries of the pesticides spiked at 10 and 50 microg kg(-1) into fish oil, pork fat, olive oil and hydrogenated vegetable oil were typically in the range 70-110% with relative standard deviations generally less than 10%. Calculated limits of detection are between 0.1 and 2.0 microg kg(-1) and results obtained for the analysis of proficiency test materials are in good agreement with assigned values. The higher selectivity of the GC-MS/MS compared to electron capture detection and GC-MS in selective ion monitoring mode allowed unambiguous identification and confirmation of all the target pesticides at low microg kg(-1) levels in fats and oils in a single analysis.
Pugajeva, Iveta; Rozentale, Irina; Viksna, Arturs; Bartkiene, Elena; Bartkevics, Vadims
2016-12-01
Selective methodology employing a tandem quadrupole mass spectrometer coupled to a gas chromatograph with headspace autosampler (HS-GC-MS/MS) was elaborated in this study. Application of the elaborated procedure resulted in a limit of detection of 0.021μgkg(-1) and a limit of quantification of 0.071μgkg(-1). The mean recoveries during in-house validation ranged from 89% to 109%, and coefficients of variation for repeatability ranged from 4% to 11%. The proposed analytical method was applied for monitoring the furan content of 30 commercial baby food samples available on the Latvian retail market. The level of furan found in these samples varied from 0.45 to 81.9μgkg(-1), indicating that infants whose sole diet comprises baby food sold in jars and cans are exposed constantly to furan. Samples containing vegetables and meat had higher levels of furan than those containing only fruits. Copyright © 2016 Elsevier Ltd. All rights reserved.
DETERMINING ION COMPOSITIONS USING AN ACCURATE MASS, TRIPLE QUADRUPOLE MASS SPECTROMETER
For the past decade, we have used double focusing mass spectrometers to determine
compositions of ions observed in mass spectra produced from compounds introduced by GC
based on measured exact masses of the ions and their +1 and +2 isotopic profiles arising from atoms of ...
Most of the published studies focusing on the environmental and biological distribution of perfluorinated alkyl compounds (PFCs) have used triple quadrupole mass spectrometers for compound identification and quantitation. Multiple-reaction-monitoring (MRM) is a sensitive mass sp...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-15
... using capillary gas liquid chromatography (GLC) with flame ionization detector (FID). Contact: Andrew...) purification. Detection and quantitation are conducted by gas chromatograph equipped with nitrogen phosphorus... pressure liquid chromatography/triple stage quadrupole mass spectrometry (LC/MS/MS) using the stable...
Székely, György; Henriques, Bruno; Gil, Marco; Alvarez, Carlos
2014-09-01
This paper discusses a design of experiments (DoE) assisted optimization and robustness testing of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method development for the trace analysis of the potentially genotoxic 1,3-diisopropylurea (IPU) impurity in mometasone furoate glucocorticosteroid. Compared to the conventional trial-and-error method development, DoE is a cost-effective and systematic approach to system optimization by which the effects of multiple parameters and parameter interactions on a given response are considered. The LC and MS factors were studied simultaneously: flow (F), gradient (G), injection volume (Vinj), cone voltage (E(con)), and collision energy (E(col)). The optimization was carried out with respect to four responses: separation of peaks (Sep), peak area (A(p)), length of the analysis (T), and the signal-to-noise ratio (S/N). An optimization central composite face (CCF) DoE was conducted leading to the early discovery of carry-over effect which was further investigated in order to establish the maximum injectable sample load. A second DoE was conducted in order to obtain the optimal LC-MS/MS method. As part of the validation of the obtained method, its robustness was determined by conducting a fractional factorial of resolution III DoE, wherein column temperature and quadrupole resolution were considered as additional factors. The method utilizes a common Phenomenex Gemini NX C-18 HPLC analytical column with electrospray ionization and a triple quadrupole mass detector in multiple reaction monitoring (MRM) mode, resulting in short analyses with a 10-min runtime. The high sensitivity and low limit of quantification (LOQ) was achieved by (1) MRM mode (instead of single ion monitoring) and (2) avoiding the drawbacks of derivatization (incomplete reaction and time-consuming sample preparation). Quantitatively, the DoE method development strategy resulted in the robust trace analysis of IPU at 1.25 ng/mL absolute concentration corresponding to 0.25 ppm LOQ in 5 g/l mometasone furoate glucocorticosteroid. Validation was carried out in a linear range of 0.25-10 ppm and presented a relative standard deviation (RSD) of 1.08% for system precision. Regarding IPU recovery in mometasone furoate, spiked samples produced recoveries between 96 and 109 % in the range of 0.25 to 2 ppm. Copyright © 2013 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Wang, Evelyn H.; Appulage, Dananjaya Kalu; McAllister, Erin A.; Schug, Kevin A.
2017-09-01
Recently, direct intact protein quantitation using triple quadrupole mass spectrometry (QqQ-MS) and multiple reaction monitoring (MRM) was demonstrated (J. Am. Soc. Mass Spectrom. 27, 886-896 (2016)). Even though QqQ-MS is known to provide extraordinary detection sensitivity for quantitative analysis, we found that intact proteins exhibited a less than 5% ion transmission from the first quadrupole to the third quadrupole mass analyzer in the presence of zero collision energy (ZCE). With the goal to enhance intact protein quantitation sensitivity, ion scattering effects, proton transfer effects, and mass filter resolution widths were examined for their contributions to the lost signal. Protein standards myoglobin and ubiquitin along with small molecules reserpine and vancomycin were analyzed together with various collision induced dissociation (CID) gases (N2, He, and Ar) at different gas pressures. Mass resolution settings played a significant role in reducing ion transmission signal. By narrowing the mass resolution window by 0.35 m/z on each side, roughly 75%-90% of the ion signal was lost. The multiply charged proteins experienced additional proton transfer effects, corresponding to 10-fold signal reduction. A study of increased sensitivity of the method was also conducted with various MRM summation techniques. Although the degree of enhancement was analyte-dependent, an up to 17-fold increase in sensitivity was observed for ubiquitin using a summation of multiple MRM transitions. Biological matrix, human urine, and equine plasma were spiked with proteins to demonstrate the specificity of the method. This study provides additional insight into optimizing the use and sensitivity of QqQ-MS for intact protein quantification. [Figure not available: see fulltext.
Pozo, Oscar J; Van Eenoo, Peter; Deventer, Koen; Elbardissy, Hisham; Grimalt, Susana; Sancho, Juan V; Hernandez, Felix; Ventura, Rosa; Delbeke, Frans T
2011-01-17
Triple quadrupole (QqQ), time of flight (TOF) and quadrupole-time of flight (QTOF) analysers have been compared for the detection of anabolic steroids in human urine. Ten anabolic steroids were selected as model compounds based on their ionization and the presence of endogenous interferences. Both qualitative and quantitative analyses were evaluated. QqQ allowed for the detection of all analytes at the minimum required performance limit (MRPL) established by the World Anti-Doping Agency (between 2 and 10 ng mL(-1) in urine). TOF and QTOF approaches were not sensitive enough to detect some of the analytes (3'-hydroxy-stanozolol or the metabolites of boldenone and formebolone) at the established MRPL. Although a suitable accuracy was obtained, the precision was unsatisfactory (RSD typically higher than 20%) for quantitative purposes irrespective of the analyser used. The methods were applied to 30 real samples declared positives either for the misuse of boldenone, stanozolol and/or methandienone. Most of the compounds were detected by every technique, however QqQ was necessary for the detection of some metabolites in a few samples. Finally, the possibility to detect non-target steroids has been explored by the use of TOF and QTOF. The use of this approach revealed that the presence of boldenone and its metabolite in one sample was due to the intake of androsta-1,4,6-triene-3,17-dione. Additionally, the intake of methandienone was confirmed by the post-target detection of a long-term metabolite. Copyright © 2010 Elsevier B.V. All rights reserved.
Van Pamel, Els; Vlaemynck, Geertrui; Heyndrickx, Marc; Herman, Lieve; Verbeken, Annemieke; Daeseleire, Els
2011-02-01
This study is the first report of applying an ultra high performance liquid chromatography/tandem mass spectrometric (UHPLC-MS/MS) multi-mycotoxin method to identify and quantify the mycotoxins produced by pure fungal isolates grown on Yeast Extract Sucrose (YES) agar. The method developed concerns a triple extraction procedure based on methanol, dichloromethane and ethyl acetate. The total extract was chromatographically separated on an UHPLC BEH C18 column and analyzed with a triple quadrupole mass spectrometer. Performance characteristics (specificity, linearity, possible matrix effects, recovery, repeatability, reproducibility and limit of detection) were evaluated by spiking experiments with blank agar plugs and the analytes. Verrucarol was used as internal standard. Recovery percentages varied between 56 and 125%, whereas the limit of detection ranged from 1 to 1,500 ng g(-1) with the exception of NIV, PAT and ZEA. The method was successfully applied for examining the in vitro mycotoxin production by Aspergillus fumigatus, A. flavus and A. niger. The mobile phases used for chromatographic separation were slightly modified when studying patulin-producing molds due to signal interference between this mycotoxin and an unknown metabolite. This modified method was successfully applied for Penicillium roqueforti, P. paneum and P. carneum grown on YES agar medium. Application of the multi-mycotoxin UHPLC-MS/MS method developed may be of great importance for studying the mycotoxin capacity of fungal isolates under varying growth conditions, in order to obtain a better insight into the conditions which induce or suppress mycotoxin production by pure fungal isolates or from a chemotaxonomic point of view.
Tandem-ESQ for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kreiner, A. J.; Escuela de Ciencia y Tecnologia, Universidad de Gral San Martin; CONICET,
2007-02-12
A folded tandem, with 1.25 MV terminal voltage, combined with an ElectroStatic Quadrupole (ESQ) chain is being proposed as a machine for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT). The machine is shown to be capable of accelerating a 30 mA proton beam to 2.5 MeV. These are the specifications needed to produce sufficiently intense and clean epithermal neutron beams, based on the on the 7Li(p,n)7Be reaction, to perform BNCT treatment for deep seated tumors in less than an hour.
Sheng, Yi-Ling; Xu, Jing-Hua; Shi, Cai-Hong; Li, Wei; Xu, Hai-Yan; Li, Ning; Zhao, Yu-Qing; Zhang, Xiang-Rong
2014-09-29
Magnolia officinalis is one of the commonly used in traditional Chinese medicine for the treatment of fever, chronic bronchitis and stomach ailments. Magnolol and honokiol are isomers with hydroxylated biphenol compound in the extract of Magnolia officinalis. This study aims to determine the isomers in rat plasma and evaluate their pharmacokinetic pattern after administration emulsion. Sprague Dawley male rats received either an intravenous (i.v.25, mg/kg) or oral (50mg/kg) dose of the emulsion of the isomer. A sensitive and specific ultra-performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS) method was developed for the investigation of the pharmacokinetics of magnolol and honokiol in rats. Kaempferol was employed as an internal standard. The plasma samples were deproteinized with acetonitrile, the post-treatment samples were analyzed on an Agela C18 column interfaced with a triple quadrupole tandem mass spectrometer in negative electrospray ionization mode. Acetonitrile and 5 mmol/L ammonium acetate buffer solution (65: 35, v/v) was used as the mobile phase at a flow rate of 0.2 mL/min. Following oral administration of emulsion to rats, magnolol attained mean peak plasma concentrations of 426.4 ± 273.8 ng/mL at 1.20 h, whereas honokiol reached peak plasma concentrations of 40.3 ± 30.8 ng/mL at 0.45 h. The absolute bioavailability of magnolol and honokiol is 17.5 ± 9.7% and 5.3 ± 11.7%. By comparison, the AUC0-∞ of magnolol was 5.4 times higher than that of honokiol after intravenous administration, but AUC0-∞ of magnolol was about 18-fold higher than honokiol after oral administration. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Sáiz, Jorge; García-Roa, Roberto; Martín, José; Gómara, Belén
2017-09-08
Chemical signaling is a widespread mode of communication among living organisms that is used to establish social organization, territoriality and/or for mate choice. In lizards, femoral and precloacal glands are important sources of chemical signals. These glands protrude chemical secretions used to mark territories and also, to provide valuable information from the bearer to other individuals. Ecologists have studied these chemical secretions for decades in order to increase the knowledge of chemical communication in lizards. Although several studies have focused on the chemical analysis of these secretions, there is a lack of faster, more sensitive and more selective analytical methodologies for their study. In this work a new GC coupled to tandem triple quadrupole MS (GC-QqQ (MS/MS)) methodology is developed and proposed for the target study of 12 relevant compounds often found in lizard secretions (i.e. 1-hexadecanol, palmitic acid, 1-octadecanol, oleic acid, stearic acid, 1-tetracosanol, squalene, cholesta-3,5-diene, α-tocopherol, cholesterol, ergosterol and campesterol). The method baseline-separated the analytes in less than 7min, with instrumental limits of detection ranging from 0.04 to 6.0ng/mL. It was possible to identify differences in the composition of the samples from the lizards analyzed, which depended on the species, the habitat occupied and the diet of the individuals. Moreover, α-tocopherol has been determined for the first time in a lizard species, which was thought to lack its expression in chemical secretions. Globally, the methodology has been proven to be a valuable alternative to other published methods with important improvements in terms of analysis time, sensitivity, and selectivity. Copyright © 2017 Elsevier B.V. All rights reserved.
Schermerhorn, Patricia G; Golden, Paul E; Krynitsky, Alexander J; Leimkuehler, William M
2005-01-01
A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed for the determination of 14 parent triazole fungicides and 8 of their metabolites found in apples, peaches, flour, raw water, and tap water. The triazole fungicides chosen for this multiresidue method development project included propiconazole, fenbuconazole and its RH-9129 and RH-9130 metabolites, cyproconazole, difenoconazole, tebuconazole and its HWG 2061 metabolite, hexaconazole, bromuconazole (both stereoisomers), epoxiconazole, tetraconazole, triticonazole and its RPA-404886 and RPA-406341 metabolites, triadimefon, triadimenol, and myclobutanil. Of special concern to the U.S. Environmental Protection Agency were the metabolites common to all triazole fungicides: free triazole, 1,2,4-triazole (T), and its 2 conjugates: triazolylalanine (TA) and triazolylacetic acid (TAA). These metabolites were the primary focus of this project. All samples we cleaned up by a combination of C18 solid-phase extraction (SPE), mixed-mode cationic SPE, and mixed-mode anionic SPE columns. A triple-stage quadrupole mass spectrometer, equipped with electrospray ionization in the positive-ion mode, was used to determine the compounds of interest. T, TA, and TAA were quantitated using isotopically labeled internal standards (IS), in which the 1,2,4-triazole ring had been synthesized by using 13C and 15N (IS_T, IS_TA, and IS_TAA). These isotopically labeled internal standards were necessary to correct for matrix effects. The T, TA, and TAA metabolites were quantitated at the 25-50 parts-per-billion (ppb) level in food commodities and at 0.50 ppb in water. Recoveries were 70-101% from apples, 60-121% from peaches, 57-118% from flour, 75-99% from raw water, and 79-99% from tap water.
Sapozhnikova, Yelena; Lehotay, Steven J
2013-01-03
A multi-class, multi-residue method for the analysis of 13 novel flame retardants, 18 representative pesticides, 14 polychlorinated biphenyl (PCB) congeners, 16 polycyclic aromatic hydrocarbons (PAHs), and 7 polybrominated diphenyl ether (PBDE) congeners in catfish muscle was developed and evaluated using fast low pressure gas chromatography triple quadrupole tandem mass spectrometry (LP-GC/MS-MS). The method was based on a QuEChERS (quick, easy, cheap, effective, rugged, safe) extraction with acetonitrile and dispersive solid-phase extraction (d-SPE) clean-up with zirconium-based sorbent prior to LP-GC/MS-MS analysis. The developed method was evaluated at 4 spiking levels and further validated by analysis of NIST Standard Reference Materials (SRMs) 1974B and 1947. Sample preparation for a batch of 10 homogenized samples took about 1h/analyst, and LP-GC/MS-MS analysis provided fast separation of multiple analytes within 9min achieving high throughput. With the use of isotopically labeled internal standards, recoveries of all but one analyte were between 70 and 120% with relative standard deviations less than 20% (n=5). The measured values for both SRMs agreed with certified/reference values (72-119% accuracy) for the majority of analytes. The detection limits were 0.1-0.5ng g(-1) for PCBs, 0.5-10ng g(-1) for PBDEs, 0.5-5ng g(-1) for select pesticides and PAHs and 1-10ng g(-1) for flame retardants. The developed method was successfully applied for analysis of catfish samples from the market. Published by Elsevier B.V.
Ren, Yan; Zhao, Weiwei; Zhao, Juanjuan; Chen, Xiangming; Yu, Chen; Liu, Mengan
2017-11-01
A simple, fast and reliable high-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous quantification and pharmacokinetic study of three flavonoids (liquiritigenin, isoliquiritigenin and formononetin) and three anthraquinones (emodin, rhein and aloe-emodin), which are the bioactive ingredients of Wei-Chang-Shu tablet found in rat plasma. After extraction by liquid-liquid extraction with ethyl acetate, chromatographic separation was achieved on an Agilent Zorbax SB-C 18 column (4.6 × 150 mm, 5 μm) at a flow rate of 1 mL/min by gradient elution using 0.1% aqueous acetic acid and acetonitrile. The detection was performed using a triple quadrupole mass spectrometer equipped with electrospray ionization source in the negative ionization and selected reaction monitoring mode. Method validation was performed in terms of specificity, carryover, linearity (r > 0.99), intra-/inter-day precision (1.0-10.1%), accuracy (relative error, <7.6%), stability (0.6-13.2%), extract recovery (74.9-91.9%) and matrix effect (89.1-109%). The lower limits of quantification of the six analytes varied from 0.92 to 10.4 ng/mL. The validated method was successfully applied to compare the pharmacokinetic properties of Wei-Chang-Shu tablet in normal rats and in rats with gastrointestinal motility disorders. The results indicated that there were obvious differences in the pharmacokinetic behavior between normal and model rats. This study will be helpful in the clinical application of Wei-Chang-Shu tablet. Copyright © 2017 John Wiley & Sons, Ltd.
Tang, Dao-quan; Zheng, Xiao-xiao; Li, Yin-jie; Bian, Ting-ting; Yu, Yan-yan; Du, Qian; Yang, Dong-zhi; Jiang, Shui-shi
2014-11-01
In this study, two independent and complementary liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods were respectively developed and validated for the determination of edaravone or taurine in rat urine, feces and bile after intravenous administration, using 3-methyl-l-p-tolyl-5-pyrazolone and sulfanilic acid as the internal standards (IS). Edaravone was separated on an Agilent Eclipse Plus C18 column (100×2.1 mm, 3.5 μm) using methanol and water (containing 5 mM ammonium formate and 0.02% formic acid) as mobile phase, while taurine was performed on a Waters Atlantis HILIC Silica column (150×2.1 mm, 3 μm) using acetonitrile and water (containing 5mM ammonium formate and 0.2% formic acid) as mobile phase. The mass analysis was performed in a Triple Quadrupole mass spectrometer via multiple reaction monitoring (MRM) with negative ionization mode. The optimized mass transition ion pairs (m/z) for quantification were 173.1→92.2 and 187.2→106.0 for edaravone and its IS, 124.1→80.0 and 172.0→80.0 for taurine and its IS, respectively. The validated methods have been successfully applied to the excretion and metabolism interaction study of edaravone and taurine in rats after independent intravenous administration and co-administration with a single dose. The results demonstrated that there were no significant alternations on the metabolism and cumulative excretion rate of edaravone and taurine, implying that the proposed combination therapy was pharmacologically viable. Copyright © 2014 Elsevier B.V. All rights reserved.
Li, Bao-Hong; Wu, Jin-Dong; Li, Xiang-Lu
2013-08-01
Bergenin, a C -glucoside of 4-O-methyl gallic acid from Bergenia purpurascens , is a naturally antitussive and expectorant agent. A rapid and sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the determination of the active component-bergenin, in rat plasma after oral administration of aqueous B. purpurascens extract. The plasma samples were pretreated by protein precipitation with acetonitrile and chromatographic separation was achieved on a Diamonsil ® C 18 column (150 mm×4.6 mm, 5 μm) with isocratic elution using a mobile phase consisting of water-methanol (30:70, v/v ) at a flow rate of 0.6 mL/min. The detection was accomplished by a triple-quadrupole tandem mass spectrometer in multiple-reaction monitoring (MRM) scanning via an electrospray ionization (ESI) source operating in the negative mode. The optimized mass transition ion-pairs ( m/z ) for quantitation were 327.3/192.0 for bergenin, and 431.1/311.1 for IS. The time for each analysis run was only 3.5 min between injections. The calibration curve exhibited good linearity ( r 2 >0.99) over a range of 1.00-2000 ng/mL for bergenin. The lower limit of quantitation (LLOQ) was 1.00 ng/mL. The intra- and inter-day precisions were no more than 11.8%, and relative errors (RE) were within the range of 0.0-4.4%. The validated method was successfully applied to investigate the pharmacokinetics of bergenin after oral administration of B. purpurascens extract in rats.
Zang, Qingce; Gao, Yang; Huang, Luojiao; He, Jiuming; Lin, Sheng; Jin, Hongtao; Zhang, Ruiping; Abliz, Zeper
2018-03-01
With the rapid development and wide application of traditional Chinese medicine injection (TCMI), a number of adverse events of some TCMIs have incessantly been reported and have drawn broad attention in recent years. Establishing effective and practical analytical methods for safety evaluation and quality control of TCMI can help to improve the safety of TCMIs in clinical applications. In this study, a sensitive and rapid high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method has been developed and validated for the quantitative determination of potentially harmful substance 5,5'-oxydimethylenebis (2-furfural, OMBF) in TCMI samples. Chromatographic separation was performed on a C18 reversed-phase column (150 mm × 2.1 mm, 5 µm) by gradient elution, using methanol-water containing 0.1% formic acid as mobile phase at the flow rate of 0.3 mL/min. MS/MS detection was performed on a triple quadrupole mass spectrometer with positive electrospray ionization in the multiple reaction-monitoring mode. The method was sensitive with a limit of quantification of 0.3 ng/mL and linear over the range of 0.3-30 ng/mL ( r =0.9998). Intra- and inter-day precision for analyte was <9.52% RSD with recoveries in the range 88.0-109.67% at three concentration levels. The validated method was successfully applied to quantitatively determine the compound OMBF in TCMIs and glucose injections. Our study indicates that this method is simple, sensitive, practicable and reliable, and could be applied for safety evaluation and quality control of TCMIs and glucose injections.
Destrez, Blandine; Bichon, Emmanuelle; Rambaud, Lauriane; Courant, Frédérique; Monteau, Fabrice; Pinel, Gaud; Antignac, Jean-Philippe; Le Bizec, Bruno
2009-10-01
Boldenone is banned in the European Union (Directive 96/22/EC) as growth promoter for meat producing animals. Boldione (ADD), boldenone and boldenone esters (mainly the undecylenate form) are commercially available as anabolic preparations, either to the destination of human, horse or cattle. Since the late 90s, the natural occurrence of boldenone metabolites has been reported in cattle. According to EU regulation, the unambiguous demonstration of boldenone administration in bovine urine should be provided on the basis of boldenone identification in the corresponding conjugate fraction. An analytical method has been developed and validated according to current standards with main concern to the measurement of intact 17beta-boldenone-sulphate. The analytical procedure included direct extraction-purification of target analyte on octadecylsilyl cartridges and direct detection of phase II metabolite by liquid chromatography (negative electrospray), tandem mass spectrometry (QqQ) or high resolution mass spectrometry (Orbitrap). Decision limit (CCalpha) and detection capability (CCbeta) were respectively 0.2 microg L(-1) and 0.4 microg L(-1) on triple quadrupole and 0.1 microg L(-1) and 0.2 microg L(-1) on hybrid system. The method was successfully applied to the analysis of incurred samples collected in different experiments. 17beta-Boldenone-sulphate was measurable up to 36h after oral administration of boldione, and 30 days after 17beta-boldenone undecylenate intra-muscular injection. This conjugate form was never detected in non-treated animals, confirming its status of definitive candidate marker for boldenone administration in calf.
Metaxalone estimation in biological matrix using high-throughput LC-MS/MS bioanalytical method.
Goswami, Dipanjan; Saha, Arabinda; Gurule, Sanjay; Khuroo, Arshad; Monif, Tausif; Vats, Poonam
2012-08-01
Metaxalone is a skeletal muscle relaxant, an approved drug for pain relief. Published bioanalytical methods lacked detailed stability evaluation in blood and plasma. An accurate, precise, high-throughput tandem mass spectroscopic method has been developed and validated. Following solid phase extraction (SPE), metaxalone and the internal standard metaxalone-d(3) were extracted from an aliquot of 200 μL of human plasma. Chromatographic separation achieved on an Ascentis Express C18 column (50 mm × 4.6 mm i.d., 2.7 μm particle size) with mobile phase is a mixture of 10mM ammonium acetate buffer (pH 4.5)-methanol-acetonitrile (20:50:30, v/v/v), at an isocratic flow rate of 0.7 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI) source. The mass transitions of metaxalone and metaxalone-d(3) were m/z 222.3→161.2 and m/z 225.3→163.3, respectively. The linear calibration curves were obtained in the concentration range of 0.105-10.081 μg/mL (r(2)≥0.99) with a lower limit of quantification (LLOQ) of 0.105 μg/mL. The intra- and inter-day precisions and relative error were all within 6%. Despite achieving high mean recovery (>78%), no interference peaks or matrix effects were observed. Detailed stability exercises including drug stability in blood, hemolyzed, lipemic and normal plasma were conducted to extend the method applicability in vast majority of clinical studies using 800 mg metaxalone extended release oral dosage form. Copyright © 2012 Elsevier B.V. All rights reserved.
Measurement of tamsulosin in human serum by liquid chromatography–tandem mass spectrometry☆
Upreti, Rita; Homer, Natalie Z.M.; Naredo, Gregorio; Cobice, Diego F.; Hughes, Katherine A.; Stewart, Laurence H.; Walker, Brian R.; Andrew, Ruth
2013-01-01
A simple, sensitive and robust method to extract tamsulosin from human serum, and quantify by liquid chromatography–tandem mass spectrometry (LC–MS/MS) was developed and validated and is applicable as a measure of compliance in clinical research. Tamsulosin was extracted from human serum (100 μL) via liquid–liquid extraction with methyl tert-butyl ether (2 mL) following dilution with 0.1 M ammonium hydroxide (100 μL), achieving 99.9% analyte recovery. Internal standard, d9-finasteride, was synthesised in-house. Analyte and internal standard were separated on an Ascentis® Express C18 (100 mm × 3 mm, 2.7 μm) column using a gradient elution with mobile phases methanol and 2 mM aqueous ammonium acetate (5:95, v/v). Total run-time was 6 min. Tamsulosin was quantified using a triple quadrupole mass spectrometer operated in multi-reaction-monitoring (MRM) mode using positive electrospray ionisation. Mass transitions monitored for quantitation were: tamsulosin m/z 409 → 228 and d9-finasteride m/z 382 → 318, with the structural formulae of ions confirmed by Fourier transform ion cyclotron resonance mass spectrometry (within 10 ppm). The limit of quantitation was 0.2 ng/mL, and the method was validated in the linear range 0.2–50 ng/mL with acceptable inter- and intra-assay precision and accuracy and stability suitable for routine laboratory practice. The method was successfully applied to samples taken from research volunteers in a clinical study of benign prostatic hyperplasia. PMID:23743242
Cai, Shuang; Wang, Lei
2012-05-15
A simple and rapid high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method has been developed and validated for the determination of 4-p-anisamidobutyric acid (ABA; or N-anysoyl-γ-aminobutiryc acid, N-anisoyl-GABA), a major active metabolite of aniracetam, in human plasma. After protein precipitation of plasma sample with methanol, ABA and the internal standard lisinopril were separated on a Venusil ASB C₁₈ column at 25 °C. The mobile phase consisted of methanol-ammonium acetate (10 mmol/L) (30:70, v/v). The detection was performed on a triple quadrupole tandem mass spectrometer with an ESI source in negative ion mode. Multiple reaction monitoring (MRM) using the precursor→product ion combinations of m/z 235.8→m/z 106.6, and m/z 403.8→m/z 113.6 was used to quantify ABA and lisinopril, respectively. This is the first LC-MS/MS method for ABA with advantages of short analysis time (4.5 min per sample run) and high selectivity attributable to the MRM detection and optimized HPLC conditions. The response was linear in a concentration range of 0.0485-19.4 μg/mL in plasma. The extraction recovery of ABA was between 89.1% and 100.7%. The precision (RSD) and accuracy (RE) of the method were evaluated to be within 7.3% and from 2.5% to 6.9%. The validated method has been applied to the pharmacokinetic study after a single oral administration of aniracetam dispersible tablets to human beings. Copyright © 2012 Elsevier B.V. All rights reserved.
Kim, Jiseon; Min, Jee Sun; Kim, Doyun; Zheng, Yu Fen; Mailar, Karabasappa; Choi, Won Jun; Lee, Choongho; Bae, Soo Kyung
2017-02-05
In this study, a simple and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of trans-ε-viniferin in small volumes (10μl) of mouse plasma using chlorpropamide as an internal standard was developed and validated. Plasma samples were precipitated with acetonitrile and separated using an Eclipse Plus C 18 column (100×4.6mm, 1.8-μm) with a mobile phase consisting of 0.1% formic acid in acetonitrile and 0.1% formic acid in water (60:40v/v) at a flow rate of 0.5ml/min. A triple quadrupole mass spectrometer operating in positive ion mode with selected reaction-monitoring mode was used to determine trans-ε-viniferin and chlorpropamide transitions of 455.10→215.05 and 277.00→111.00, respectively. The lower limit of quantification was 5ng/ml with a linear range of 5-2500ng/ml (r≥0.9949). All validation data, including the selectivity, precision, accuracy, recovery, dilution integrity, and stability, conformed to the acceptance requirements. No matrix effects were observed. The developed method was successfully applied to pharmacokinetic studies of trans-ε-viniferin following intravenous (2.5mg/kg), intraperitoneal (2.5, 5 and 10mg/kg), and oral (40mg/kg) administration in mice. This is the first report on the pharmacokinetic properties of trans-ε-viniferin. The results provide a meaningful basis for evaluating the pre-clinical or clinical applications of trans-ε-viniferin. Copyright © 2016 Elsevier B.V. All rights reserved.
Al-Alam, Josephine; Fajloun, Ziad; Chbani, Asma; Millet, Maurice
2017-08-01
An optimized analytical method was developed for the simultaneous analysis of 90 pesticides, 16 polycyclic aromatic hydrocarbons, and 22 polychlorinated biphenyls. The method was based on quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction using acetonitrile followed by a dispersive solid-phase extraction cleanup using primary-secondary amine and octadecyl (C 18 ). The extract obtained was concentrated by evaporation and then reconstituted with acetonitrile to prepare it for chromatographic analysis by liquid chromatography-triple-quadrupole tandem mass spectrometry and gas chromatography-ion-trap tandem mass spectrometry, which was preceded by a preconcentration step using solid-phase microextraction with appropriate fibers. The combination of the two extraction steps ensured efficient extract cleanup. The use of the two analytical instruments allowed the analysis of a large number of pollutants with a high reliability rate. The method developed was validated for linearity, which was studied with use of matrix-matched calibration curves in the concentration range between 10 and 3000 ng g -1 . The correlation coefficient (R 2 ) obtained was higher than 0.98 for most of the target compounds, with a relative standard deviation lower than 20% for repeatability and reproducibility. The limits of detection and quantification were lower than 20 and 60 ng g -1 respectively for the compounds analyzed, and the recoveries were between 60% and 103% for most compounds. Finally, the method was tested for its efficiency on real samples by the analysis of three honey samples in which seven pesticides and nine polycyclic aromatic hydrocarbons were determined. Graphical Abstract ᅟ.
Voehringer, Patrizia; Fuertig, René; Ferger, Boris
2013-11-15
Glycine is an important amino acid neurotransmitter in the central nervous system (CNS) and a useful biomarker to indicate biological activity of drugs such as glycine reuptake inhibitors (GRI) in the brain. Here, we report how a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method for the fast and reliable analysis of glycine in brain microdialysates and cerebrospinal fluid (CSF) samples has been established. Additionally, we compare this method with the conventional approach of high performance liquid chromatography (HPLC) coupled to fluorescence detection (FD). The present LC-MS/MS method did not require any derivatisation step. Fifteen microliters of sample were injected for analysis. Glycine was detected by a triple quadrupole mass spectrometer in the positive electrospray ionisation (ESI) mode. The total running time was 5min. The limit of quantitation (LOQ) was determined as 100nM, while linearity was given in the range from 100nM to 100μM. In order to demonstrate the feasibility of the LC-MS/MS method, we measured glycine levels in striatal in vivo microdialysates and CSF of rats after administration of the commercially available glycine transporter 1 (GlyT1) inhibitor LY 2365109 (10mg/kg, p.o.). LY 2365109 produced 2-fold and 3-fold elevated glycine concentrations from 1.52μM to 3.6μM in striatal microdialysates and from 10.38μM to 36μM in CSF, respectively. In conclusion, we established a fast and reliable LC-MS/MS method, which can be used for the quantification of glycine in brain microdialysis and CSF samples in biomarker studies. Copyright © 2013 Elsevier B.V. All rights reserved.
Ripollés, Cristina; Pitarch, Elena; Sancho, Juan V; López, Francisco J; Hernández, Félix
2011-09-19
In this work, we have developed a sensitive method for detection and quantification of eight N-nitrosamines, N-nitrosodimethylamine (NDMA), N-nitrosomorpholine (NMor), N-nitrosomethylethylamine (NMEA), N-nitrosopirrolidine (NPyr), N-nitrosodiethylamine (NDEA), N-nitrosopiperidine (NPip), N-nitroso-n-dipropylamine (NDPA) and N-nitrosodi-n-butylamine (NDBA) in drinking water. The method is based on liquid chromatography coupled to tandem mass spectrometry, using atmospheric pressure chemical ionization (APCI) in positive mode with a triple quadrupole analyzer (QqQ). The simultaneous acquisition of two MS/MS transitions in selected reaction monitoring mode (SRM) for each compound, together with the evaluation of their relative intensity, allowed the simultaneous quantification and reliable identification in water at ppt levels. Empirical formula of the product ions selected was confirmed by UHPLC-(Q)TOF MS accurate mass measurements from reference standards. Prior to LC-MS/MS QqQ analysis, a preconcentration step by off-line SPE using coconut charcoal EPA 521 cartridges (by passing 500 mL of water sample) was necessary to improve the sensitivity and to meet regulation requirements. For accurate quantification, two isotope labelled nitrosamines (NDMA-d(6) and NDPA-d(14)) were added as surrogate internal standards to the samples. The optimized method was validated at two concentration levels (10 and 100 ng L(-1)) in drinking water samples, obtaining satisfactory recoveries (between 90 and 120%) and precision (RSD<20%). Limits of detection were found to be in the range of 1-8 ng L(-1). The described methodology has been applied to different types of water samples: chlorinated from drinking water and wastewater treatment plants (DWTP and WWTP, respectively), wastewaters subjected to ozonation and tap waters. Copyright © 2011 Elsevier B.V. All rights reserved.
Liu, Yongli; Liu, Youping; Qiu, Feng; Di, Xin
2011-03-25
The present paper describes a novel, sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous analysis of ganoderic acids C(2), B, A, H, D in Ganoderma lucidum and its related species. Ganoderma samples were prepared using simple ultrasonic extraction. Chromatographic separation was carried out on an Agilent Zorbax XDB C(18) column (250 mm × 4.6 mm i.d., 5μm) with an isocratic mobile phase consisting of acetonitrile, water and formic acid (42:58:0.5, v/v/v). Mass spectrometric detection was achieved by a triple-quadrupole mass spectrometer equipped with an atmospheric pressure chemical ionization (APCI) interface operating in negative and positive ionization mode via a single within-run polarity switching. Quantitation of five ganoderic acids was performed using selective reaction monitoring (SRM) mode. The intra- and inter-day precision was less than 6.2% and the accuracy ranged from 90.0% to 105.7%. The limit of quantification (LOQ) was 20.0-40.0 ng/mL and the limit of detection (LOD) was 3.0-25.0 ng/mL. With this method, low levels of ganoderic acids in the fruiting bodies of Ganoderma sinense and Ganoderma applanatum were accurately quantified for the first time. Importantly, the method allows unequivocal quantification of the five ganoderic acids in the spores and fruiting bodies of Ganoderma lucidum, whereas the previously published methods have lacked the capability. The method presented will be a powerful tool for quality control of Ganoderma lucidum and its related species. Copyright © 2010 Elsevier B.V. All rights reserved.
Wang, Shufang; Cheng, Ling; Ji, Shen; Wang, Ke
2014-09-01
This work reported an efficient and accurate liquid chromatography tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of seventeen mycotoxins in Puerariae lobatae radix, a frequently used traditional Chinese medicine (TCM). The effects of four different clean-up methods, including TC-M160, TC-T220, Mycosep 227, and QuEChERS method, on the recoveries of mycotoxins were investigated and compared. Finally, TC-M160 was chosen for better recovery and repeatability for mycotoxins analysis. The analytes were separated on an Agilent ZORBAX SB C18 column (4.6mm×250mm, 5μm particle size), and eluted with a mobile phase consisting of (A) water containing 0.1% formic acid and (B) acetonitrile containing 0.1% formic acid at a flow rate of 0.6mL/min. The separated compounds were detected by a triple quadrupole mass spectrometer operating in positive electrospray ionization with multiple reaction monitoring (MRM) mode. The results of method validation accorded with the requirement of analytical method for mycotoxins in COMMISSION REGULATION (EC) No 401/2006. The developed method was successfully applied for determination of mycotoxins in seventeen batches of Puerariae lobatae radix collected from different provinces of China. Three batches of them were found with contamination of mycotoxins AFB1 at (0.751±0.176)μg/kg, T-2 at (1.10±0.01)μg/kg, and T-2 at (0.853±0.044)μg/kg, respectively. The results demonstrated that the proposed method was suitable for monitoring mycotoxins residues in Puerariae lobatae radix. Copyright © 2014 Elsevier B.V. All rights reserved.
González-Sálamo, Javier; Socas-Rodríguez, Bárbara; Hernández-Borges, Javier; Rodríguez-Delgado, Miguel Ángel
2017-12-29
In this work, the first application of core-shell poly(dopamine) magnetic nanoparticles as sorbent for the extraction of a group of eleven phthalic acid esters of interest (i.e. diethyl phthalate (DEP), dipropyl phthalate (DPP), dibutyl phthalate (DBP), bis-isopentyl phthalate (DIPP), bis-n-pentyl phthalate (DNPP), benzylbutyl phthalate (BBP), dicyclohexyl phthalate (DCHP), di-(2-ethylhexyl) phthalate (DEHP), di-n-octyl phthalate (DNOP), diisononyl phthalate (DINP) and diisodecyl phthalate (DIDP)) and one adipate (bis (2-ethylhexyl) adipate, DEHA) from different water samples (Milli-Q, mineral, tap, pond and waste water) is proposed. Analysis were carried out by gas chromatography triple quadrupole tandem mass spectrometry. Parameters that affect the extraction performance were optimized following a step by step approach, being the optimum conditions the extraction of water at pH 6, with 60mg of sorbent and the elution with 6mL of dichloromethane. The methodology was validated for the five selected water samples using DBP-d 4 as internal standard. Determination coefficients of matrix-matched calibration curves were above 0.9904 in all cases while relative recovery values ranged between 71 and 120%, with relative standard deviation values below 19%. The limits of quantification of the method ranged between 9 and 20ng/L. Matrix effects were found for most analytes and water samples. Real water samples were also analyzed, finding DEP and DBP at concentrations below 4.20 and 1.23μg/L, respectively, in mineral, tap and waste water. DCHP, DEHP and BBP were also found in some of the samples at concentrations below the LOQs of the method. Copyright © 2017 Elsevier B.V. All rights reserved.
Cho, Sang-Hyun; Park, Jin-A; Zheng, Weijia; Abd El-Aty, A M; Kim, Seong-Kwan; Choi, Jeong-Min; Yi, Hee; Cho, Soo-Min; Afifi, Nehal A; Shim, Jae-Han; Chang, Byung-Joon; Kim, Jin-Suk; Shin, Ho-Chul
2017-10-15
In this study, a simple analytical approach has been developed and validated for the determination of bupivacaine hydrochloride and isoflupredone acetate residues in porcine muscle, beef, milk, egg, shrimp, flatfish, and eel using liquid chromatography-tandem mass spectrometry (LC-MS/MS). A 0.1% solution of acetic acid in acetonitrile combined with n-hexane was used for deproteinization and defatting of all tested matrices and the target drugs were well separated on a Waters Xbridge™ C18 analytical column using a mobile phase consisting of 0.1% acetic acid (A) and 0.1% solution of acetic acid in methanol (B). The linearity estimated from six-point matrix-matched calibrations was good, with coefficients of determination ≥0.9873. The limits of quantification (LOQs) for bupivacaine hydrochloride and isoflupredone acetate were 1 and 2ngg -1 , respectively. Recovery percentages in the ranges of 72.51-112.39% (bupivacaine hydrochloride) and 72.58-114.56% (isoflupredone acetate) were obtained from three different fortification concentrations with relative standard deviations (RSDs) of <15.14%. All samples for the experimental work and method application were collected from the local markets in Seoul, Republic of Korea, and none of them tested positive for the target drugs. In conclusion, a simple method using a 0.1% solution of acetic acid in acetonitrile and n-hexane followed by LC-MS/MS could effectively extract bupivacaine hydrochloride and isoflupredone acetate from porcine muscle, beef, milk, egg, shrimp, flatfish, and eel samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Ruiz-Delgado, Ana; Arrebola-Liébanas, Francisco Javier; Romero-González, Roberto; López-Ruiz, Rosalía; Garrido Frenich, Antonia
2016-10-01
A highly sensitive analytical method was developed to determine 2,4,6-trichloroanisole (TCA), 2,3,4,6-tetrachloroanisole (TeCA), 2,4,6-tribromoanisole (TBA) and 2,3,4,5,6-pentachloroanisole (PCA) in sparkling alcoholic beverages. The method was based on the use of headspace solid-phase microextraction (HS-SPME) using a polydimethylsiloxane (PDMS) fibre. It was coupled to gas chromatography-triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS) for the detection and quantification of the target haloanisoles. The method was fully automated and no sample preparation was needed. The method was validated for alcoholic beverages. The influence of CO 2 on the extraction efficiency was also evaluated for the studied sparkling drinks (cava and cider). All the calibration curves showed good linearity (R 2 > 0.98) within the tested range (1-50 ng l -1 ). Recoveries were evaluated at three different levels (1, 5 and 50 ng l -1 ) and were always between 71% and 119%. Precision was expressed as relative standard deviation (RSD), and was evaluated as intra- and inter-day precisions, with values ≤ 22% in both cases. Limits of quantitation (LOQs) were ≤ 0.91 ng l -1 , which are below the sensory threshold levels for such compounds in humans. The validated method was applied to commercial samples, 10 cavas and 10 ciders, but it was also used for the analysis of nine red wines and four white wines, demonstrating the further applicability of the proposed method to non-sparkling beverages. TCA was detected in most samples at up to 0.45 ng l -1 .
Barco, Sebastiano; Castagnola, Elio; Gennai, Iulian; Barbagallo, Laura; Loy, Anna; Tripodi, Gino; Cangemi, Giuliana
2016-10-01
Vancomycin therapeutic drug monitoring (TDM) is necessary for effective and safetherapy. The aim of the this paper was to develop a specific and robust ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for vancomycin quantification starting from low plasma volumes to be applied for the routine TDM in children. Samples from children receiving intravenous vancomycin were analysed using a TSQ Quantum Access MAX Triple Quadrupole system coupled with an Accela 1250 UHPLC system after a rapid protein precipitation. Gradient separation chromatography was carried out using a Hypersil GOLD aQ C18 column (50 × 2.1 mm, particle size 1.9 μm). Method performance was validated following international guidelines. UHPLC-MS/MS allowed a rapid and specific quantification of vancomycin over the range 0.1-128 μg/mL from 50 μL of plasma with high reproducibility and accuracy in the absence of matrix effect. The comparison with the commercial immunoassay performed on 138 samples demonstrated the presence of a proportional bias. The concentrations of vancomycin measured with immunoassay were found to be 4.5% (95% CI: 1.3-7.7) higher than those determined with UHPLC-MS/MS. Importantly, a clinical discordance was found in about 10% of samples analysed. This new UHPLC-MS/MS method is accurate and specific for the measurement of vancomycin starting from small (50 μL) plasma volumes. The use of UHPLC-MS/MS is recommended to prevent a misclassification of therapeutic or toxic vancomycin levels in paediatrics.
Lien, Guang-Wen; Wen, Ting-Wen; Hsieh, Wu-Shiun; Wu, Kuen-Yuh; Chen, Chia-Yang; Chen, Pau-Chung
2011-03-15
Perfluorinated compounds (PFCs) can cross the placental barrier and enter fetal circulation. This study aimed at developing a fast and sensitive ultra-high performance liquid chromatography/tandem mass spectrometry method for the determination of twelve perfluorinated compounds in cord blood. Samples were processed with protein precipitation using formic acid and methanol, mixed with stable isotope labeled standard, followed by sonication and centrifugation, and were analyzed using a Waters ACQUITY UPLC coupled with a Waters Quattro Premier XE triple-quadrupole mass spectrometer. The instrument was operated in selected reaction monitoring (SRM) with negative electrospray ionization. Using BEH C(18) column (2.1 mm×50 mm, 1.7 μm) with 10-mM N-methylmorpholine/methanol gradient elution provided a fast chromatographic separation (5.5 min) and sharp peaks. Intra- and inter-day calibration bias was less than 7% and intra- and inter-day calibration of relative standard deviations were within 0.02-8.22% for all the analytes and concentrations. The recoveries of PFCs spiked into bovine serum ranged from 85 to 104% with relative standard deviations from 0.02 to 6.37%. The limits of quantitation (LOQs), defined as a signal-to-noise ratio of ten, ranged from 0.15 to 3.1 ng/mL for the twelve PFCs. Perfluorooctanoic acid (PFOA), perfluorooctyl sulfonate (PFOS), perfluoroundecanoic acid (PFUA) and perfluorononanoic acid (PFNA) were detected in up to 68% of umbilical cord plasma (n=444) in Taiwan Birth Panel Study and the health effect of these chemicals on children developmental deserves further investigation. Copyright © 2011 Elsevier B.V. All rights reserved.
Termopoli, Veronica; Famiglini, Giorgio; Palma, Pierangela; Magrini, Laura; Cappiello, Achille
2015-03-01
Sudden infant death syndrome (SIDS) and sudden intrauterine unexpected death syndrome (SIUDS) are an unresolved teaser in the social-medical and health setting of modern medicine and are the result of multifactorial interactions. Recently, prenatal exposure to environmental contaminants has been associated with negative pregnancy outcomes, and verification of their presence in fetal and newborn tissues is of crucial importance. A gas chromatography-tandem mass spectrometry (MS/MS) method, using a triple quadrupole analyzer, is proposed to assess the presence of 20 organochlorine pesticides, two organophosphate pesticides, one carbamate (boscalid), and a phenol (bisphenol A) in human brain tissues. Samples were collected during autopsies of infants and fetuses that died suddenly without any evident cause. The method involves a liquid-solid extraction using n-hexane as the extraction solvent. The extracts were purified with Florisil cartridges prior to the final determination. Recovery experiments using lamb brain spiked at three different concentrations in the range of 1-50 ng g(-1) were performed, with recoveries ranging from 79 to 106%. Intraday and interday repeatability were evaluated, and relative standard deviations lower than 10% and 18%, respectively, were obtained. The selectivity and sensitivity achieved in multiple reaction monitoring mode allowed us to achieve quantification and confirmation in a real matrix at levels as low as 0.2-0.6 ng g(-1). Two MS/MS transitions were acquired for each analyte, using the Q/q ratio as the confirmatory parameter. This method was applied to the analysis of 14 cerebral cortex samples (ten SIUDS and four SIDS cases), and confirmed the presence of several selected compounds.
Ni, Yang; Zhou, Ying; Xu, Mingzhen; He, Xiaomeng; Li, Huqun; Haseeb, Satter; Chen, Hui; Li, Weiyong
2015-03-25
A new method for simultaneous determination of phentermine and topiramate by liquid chromatography/electrospray tandem mass spectrometry (LC/MS/MS) operated in positive and negative ionization switching modes was developed and validated. Protein precipitation with acetonitrile was selected for sample preparation. Analyses were performed on a liquid chromatography system employing a Kromasil 60-5CN column (2.1 mm × 100 mm, 5 μm) and an isocratic elution with mixed solution of acetonitrile-20mM ammonium formate containing 0.3% formic acid (40:60, v/v), at a flow rate of 0.35 mL/min. Doxazosin mesylate and pioglitazone were used as the internal standard (IS) respectively for quantification. The determination was carried out on an API 4000 triple-quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode using the following transitions monitored simultaneously: positive m/z 150.0/91.0 for phentermine, m/z 452.1/344.3 for doxazosin, and negative m/z 338.3/77.9 for topiramate, m/z 355.0/41.9 for pioglitazone. The method was validated to be linear over the concentration range of 1-800 ng mL(-1) for phentermine, 1-1000 ng mL(-1) for topiramate. Within- and between-day accuracy and precision of the validated method at three different concentration levels were within the acceptable limits of <15% at all concentrations. Blood samples were collected into heparinized tubes before and after administration. The simple and robust LC/MS/MS method was successfully applied for the simultaneous determination of phentermine and topiramate in a pharmacokinetic study in healthy male Chinese volunteers. Copyright © 2015 Elsevier B.V. All rights reserved.
Eckart, K; Röhrich, J; Breitmeier, D; Ferner, M; Laufenberg-Feldmann, R; Urban, R
2015-09-15
A liquid chromatography-tandem mass spectrometry method using electrospray ionization in positive ionization mode was developed for the simultaneous detection of multiple opioid-type drugs in plasma. The presented assay allows the quantitative determination of alfentanil, buprenorphine, codeine, desomorphine, dextromethorphan, dextrorphan, dihydrocodeine, dihydromorphine, ethylmorphine, fentanyl, hydrocodone, hydromorphone, methadone, morphine, naloxone, naltrexone, oxycodone, oxymorphone, pentazocine, pethidine, pholcodine, piritramide, remifentanil, sufentanil, and tramadol as well as the metabolites 6-monoacetylmorphine, bisnortilidine, morphine-3-glucuronide, morphine-6-glucuronide, naltrexol, norbuprenorphine, norfentanyl, norpethidine, nortilidine, and O-desmethyltramadol. Serum and blood samples were purified by solid-phase extraction. The analytes were separated on a phenyl-hexyl (100mm) column by formic acid/acetonitrile gradient elution using an UPLC 1290 Infinity coupled with a 6490 Triple Quadrupole mass spectrometer. The limits of detection ranged from 0.02 to 0.6ng/mL and the lower limits of quantification ranged from 0.1 to 2.0ng/mL. The calibration curves were linear between Calibration Levels 1-6 for all 35 substances. Recovery rates ranged between 51 and 88% for all compounds except alfentanil, bisnortilidine, pethidine, and morphine-3-glucuronide. The matrix effect ranged from 86% for ethylmorphine to 105% for desomorphine. Using the validation procedure proposed by the German Society of Toxicological and Forensic Chemistry, acceptable precision and accuracy data for almost all analytes were obtained. The method was successfully applied to 206 authentic serum samples provided by the palliative and intensive care units of the University Medical Center and the police authorities. Furthermore, a suspected fatal intoxication is demonstrated by an analysis of the sufentanil in post mortem body fluids and tissues. Copyright © 2015 Elsevier B.V. All rights reserved.
Caballo, C; Sicilia, M D; Rubio, S
2013-01-25
Liquid chromatography (LC)/tandem mass spectrometry (MS/MS) after supramolecular solvent-based microextraction (SUSME) was firstly used in this work for the enantioselective determination of chiral pesticides in natural waters. The method developed for the quantitation of the R- and S-enantiomers of mecoprop (MCPP) and dichlorprop (DCPP) involved the extraction of the herbicides in a supramolecular solvent (SUPRAS) made up of reverse aggregates of dodecanoic acid (DoA), analyte re-extraction in acetate buffer (pH = 5.0), separation of the target enantiomers on a chiral column of permethylated α-cyclodextrin under isocratic conditions, and detection of the daughter ions (m/z = 140.9 and 160.6 for MCPP and DCPP, respectively) using a hybrid triple quadrupole mass spectrometer equipped with an electrospray source operating in the negative ion mode. Similar recoveries (ca. 75%) and actual concentration factors (ca. 94) were obtained for both phenoxypropanoic acids (PPAs). The quantitation limits were 1 ng L(-1) for R- and S-MCPP, and 4 ng L(-1) for R- and S-DCPP, and the precision, expressed as relative standard deviation (n = 6) was in the ranges 2.4-2.7% ([R-MCPP] = [S-MCPP] = 5 ng L(-1) and [R-DCPP] = [S-DCPP] = 15 ng L(-1)) and 1.6-1.8% (100 ng L(-1) of each enantiomer). The SUSME-LC-MS/MS method was successfully applied to the determination of the enantiomers of MCPP and DCPP in river and underground waters, fortified at concentrations between 15 and 180 ng L(-1) at variable enantiomeric ratios (ER = 1-9). Copyright © 2012 Elsevier B.V. All rights reserved.
Yan, Huiyu; Tao, Lina; Qu, Xiaoyu; Zhou, Liting; Zhang, Sixi
2018-05-01
Mogroside V is the most abundant (approximately 0.50%) cucurbitane-type triterpene glycoside in Siraitia grosvenorii and exhibits significant antitussive, expectorant, anti-carcinogenic, and anti-inflammatory effects. A sensitive, robust and selective liquid chromatography tandem with mass spectrometry (LC-MS/MS) was developed and validated for the determination and pharmacokinetic investigation of mogroside V in rat plasma. Samples were prepared through an one-step deproteinization procedure with 250 µL of methanol to a 75-µL plasma sample. Plasma samples were effectively separated on a Shiseido Capcell Pak UG120 C18 column (2.0 × 50mm, 3.0µm) using a mobile phase consisting of methanol: water (60:40, v/v) with an isocratic elution program. The running time for each sample was 7.0 min and the elution times of mogroside V and IS were 2.0 and 4.8 min, respectively. The detection relied on a triple-quadrupole tandem with mass spectrometer equipped with negative-ion electrospray ionization interface by selected-reaction monitoring (SRM) of the transitions at m/z 1285.6 → 1123.7 for mogroside V and m/z 1089.6 → 649.6 for IS. The calibration curve was linear over the range of 96.0-96000ng/mL with a limit of quantitation (LOQ) of 96.0ng/mL. Intra-day and inter-day precisions were both <10.1%. Mean recovery and matrix effect of mogroside V in plasma were in the range of 91.3-95.7% and 98.2-105.0%, respectively. This method was successfully applied in the pharmacokinetic study of mogroside V after intravenous or intraperitoneal administration of 1.12mg/kg mogroside V in rats.
Wu, Yun; Wang, Fenrong; Ai, Yu; Ma, Wen; Bian, Qiaoxia; Lee, David Y-W; Dai, Ronghua
2015-06-01
A simple, sensitive and reliable ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method has been developed and validated for simultaneous quantitation of seven coumarins, the bio-active ingredients of Huo Luo Xiao Ling Dan (HLXLD), in rat plasma. The liquid-liquid extraction method with ether-dichloromethane (2:1, v/v) was used to prepare the plasma samples. Analytes and internal standard (IS) of bifendate were separated on a Shim-pack XR-ODS column (75mm×3.0mm, 2.2μm particles) using gradient elution with the mobile phase consisting of methanol and 0.05% formic acid in water at a flow rate of 0.4mL/min. Detection was performed on a triple quadrupole (TQ) tandem mass spectrometry equipped with an electrospray ionization source in the positive ionization and multiple reaction monitoring (MRM) mode. The lower limits of quantitation (LLOQ) were 0.03-0.25ng/mL for all the analytes. Intra- and inter-day precision and accuracy of the seven analytes were well within acceptance criteria (15%). The matrix effect and the mean extraction recoveries of the analytes and IS from rat plasma were all within satisfaction. The validated method has been successfully applied to compare pharmacokinetic profiles of the seven active ingredients in rat plasma between normal and arthritic rats after oral administration of HLXLD, Angelica pubescens extract and Notopterygium incisum extract, respectively. Results showed that there were remarkable differences in pharmacokinetic properties of the analytes among the different groups. Copyright © 2015. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Wabaidur, Saikh Mohammad; Alothman, Zeid Abdullah; Khan, Mohammad Rizwan
2013-05-01
In present study, a rapid and sensitive method using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of L-ascorbic acid and acetylsalicylic acid in aspirin C effervescent tablet. The optimum chromatographic separation was carried out on a reversed phase Waters® Acquity UPLC BEH C18 column (1.7 μm particle size, 100 mm × 2.1 mm ID) with an isocratic elution profile and mobile phase consisting of 0.1% formic acid in water and acetonitrile (75:25, v/v, pH 3.5) at flow rate of 0.5 mL min-1. The influences of mobile phase composition, flow rate and pH on chromatographic resolution were investigated. The total chromatographic analysis time was as short as 2 min with excellent resolution. Detection and quantification of the target compounds were carried out with a triple quadrupole mass spectrometer using negative electrospray ionization (ESI) and multiple reaction monitoring (MRM) modes. The performance of the method was evaluated and very low limits of detection less than 0.09 μg g-1, excellent coefficient correlation (r2 > 0.999) with liner range over a concentration range of 0.1-1.0 μg g-1 for both L-ascorbic acid and acetylsalicylic acid, and good intraday and interday precisions (relative standard deviations (R.S.D.) <3%), were obtained. Comparison of system performance with traditional liquid chromatography-photo diode array detector (HPLC-PDA) was made with respect to analysis time, sensitivity, linearity and precisions. The proposed UPLC-MS/MS method was found to be reproducible and appropriate for quantitative analysis of L-ascorbic acid and acetylsalicylic acid in aspirin C effervescent tablet.
Chen, Tsung-Chi; Fillmore, Thomas L.; Prost, Spencer A.; ...
2015-06-24
The electrodynamic ion funnel facilitates efficient focusing and transfer of charged particles in the higher pressure regions (e.g. ion source interfaces) of mass spectrometers, and thus providing increased sensitivity. An “off-axis” ion funnel design has been developed to reduce the source contamination and interferences from, e.g. ESI droplet residue and other poorly focused neutral or charged particles with very high mass-to charge ratios. In this study a dual ion funnel interface consisting of an orthogonal higher pressure electrodynamic ion funnel (HPIF) and an ion funnel trap combined with a triple quadruple mass spectrometer was developed and characterized. An orthogonal ionmore » injection inlet and a repeller plate electrode was used to direct ions to an ion funnel HPIF at 9-10 Torr pressure. Several critical factors for the HPIF were characterized, including the effects of RF amplitude, DC gradient and operating pressure. Compared to the triple quadrupole standard interface more than 4-fold improvement in the limit of detection for the direct quantitative MS analysis of low abundance peptides was observed. Lastly, the sensitivity enhancement in liquid chromatography selected reaction monitoring (SRM) analyses of low abundance peptides spiked into a highly complex mixture was also compared with that obtained using a both commercial s-lens interface and a in-line dual ion funnel interface.« less
Most compounds are not found in mass spectral libraries and must be identified by other means. Often, compound identities can be deduced from the compositions of the ions in their mass spectra and review of the chemical literature. Confirmation is provided by mass spectra and r...
Wu, Chunying; Gu, Feng; Bai, Lu; Lu, Wenlong
2015-08-01
An analytical method for simultaneous determination of 22 typical pharmaceuticals and personal care products (PPCPs) in environmental water samples was developed by ultra performance liquid chromatography-triple quadrupole mass spectrometry (UPLC-MS/MS). An Oasis HLB solid phase extraction cartridge, methanol as washing solution, water containing 0. 1% formic acid-methanol (7:3, v/v) as the mobile phases were selected for sample pretreatment and chromatographic separation. Based on the optimized sample pretreatment procedures and separation condition, the target recoveries ranged from 73% to 125% in water with the relative standard deviations ( RSDs) from 8.8% to 17.5%, and the linear ranges were from 2 to 2 000 µg/L with correlation coefficients (R2) not less than 0.997. The method can be applied to simultaneous determination of the 22 typical PPCPs in environmental water samples because of its low detection limits and high recoveries. It can provide support and help for the related research on water environmental risk assessment and control of the micro-organic pollutants.
Yan, Zhou; Xia, Bing; Qiu, Ming Hua; Li Sheng, Ding; Xu, Hong Xi
2013-11-01
A rapid and reliable method was established for simultaneous determination of main triterpenoids in Ganoderma lucidum spores using ultra-high-performance liquid chromatography coupled with triple quadrupole mass spectrometry (UPLC-TQ-MS). The established method was validated in terms of linearity, sensitivity, precision, accuracy and stability, and was successfully applied to determine the contents of 10 main triterpenoids in different batches of G. lucidum spores. The analysis results showed that moderate levels of triterpenoids were found in G. lucidum spores. In addition, a MS full scan with a daughter ion scan experiment was performed to identify the potential derivatives of triterpenoids present in G. lucidum spores. As a result, a total of 22 triterpenoids from different G. lucidum spores were unequivocally or tentatively identified via comparisons with authentic standards and literatures. This method provides both qualitative and quantitative results without the need for repetitive UPLC-MS analyses, thereby increasing efficiency and productivity, making it suitable for high-throughput applications. Copyright © 2013 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Ranković, Milos Lj.; Giuliani, Alexandre; Milosavljević, Aleksandar R.
2016-06-01
A new apparatus was designed, coupling an electron gun with a linear quadrupole ion trap mass spectrometer, to perform m/ z (mass over charge) selected ion activation by electron impact for tandem mass spectrometry and action spectroscopy. We present in detail electron tracing simulations of a 300 eV electron beam inside the ion trap, design of the mechanical parts, electron optics and electronic circuits used in the experiment. We also report examples of electron impact activation tandem mass spectra for Ubiquitin protein, Substance P and Melittin peptides, at incident electron energies in the range from 280 eV to 300 eV.
Musharraf, Syed Ghulam; Siddiqui, Amna Jabbar; Shamsi, Tahir; Naz, Arshi
2017-12-01
Acute leukaemia (AL) is a critical neoplasm of white blood cells. Diagnosing AL requires bone marrow puncture procedure, which many patients do not consent to for it is invasive. Hence sensitive and specific early diagnostic biomarkers are essential for non-invasive diagnosis, new therapeutics and improving the disease prognosis. To differentiate the metabolic alterations associated with acute lymphoblastic leukaemia (ALL) and acute myeloid leukaemia (AML), we investigated serum of ALL and AML patients in comparison with two controls using gas chromatography coupled with triple quadrupole tandem mass spectrometry and multivariate statistical analysis. Twenty seven out of 1425 metabolites were found differentiative among ALL, AML, aplastic anaemia (APA) patients and healthy control using p-value ≤ 0.001. ALL is the most dissimilar group from other three groups as in hierarchical clustering showed 72.1% dissimilarity. Model generation using PLSDA gave an overall accuracy of 91.9%. This study helps in metabolic fingerprinting of control and disease serum at high significance levels and could be used for early diagnosing of AL. Based on pathways analysis, fatty acid metabolism is deregulated in patients with AL and may represent an underlying metabolic pathway associated with disease progression. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Charles, Laurence; Laure, Frédéric; Raharivelomanana, Phila; Bianchini, Jean-Pierre
2005-01-01
A novel interface that allows normal-phase liquid chromatography to be coupled with electrospray ionization (ESI) is reported. A make-up solution of 60 mM ammonium acetate in methanol, infused at a 5 microl min(-1) flow-rate at the tip of the electrospray probe, provides a sheath liquid which is poorly miscible with the chromatographic effluent, but promotes efficient ionization of the targeted analytes. Protonated molecules generated in the ESI source were subjected to tandem mass spectrometric experiments in a triple-quadrupole mass spectrometer. The main fragmentation reactions were characterized for each analyte and specific mass spectral transitions were used to acquire chromatographic data in the multiple reaction monitoring detection mode. Results obtained during optimization of the sheath liquid composition and flow-rate suggest that the electrospray process was mainly under the control of the make-up solution, and that it forms an external charged layer around a neutral chromatographic mobile phase core. This sheath liquid interface was implemented for the analysis of some neoflavonoid compounds and its performance was evaluated. Limits of detection were established for calophillolide, inophyllum B, inophyllum P and inophyllum C at 100, 25, 15 and 100 ng ml(-1), respectively.
Review of software tools for design and analysis of large scale MRM proteomic datasets.
Colangelo, Christopher M; Chung, Lisa; Bruce, Can; Cheung, Kei-Hoi
2013-06-15
Selective or Multiple Reaction monitoring (SRM/MRM) is a liquid-chromatography (LC)/tandem-mass spectrometry (MS/MS) method that enables the quantitation of specific proteins in a sample by analyzing precursor ions and the fragment ions of their selected tryptic peptides. Instrumentation software has advanced to the point that thousands of transitions (pairs of primary and secondary m/z values) can be measured in a triple quadrupole instrument coupled to an LC, by a well-designed scheduling and selection of m/z windows. The design of a good MRM assay relies on the availability of peptide spectra from previous discovery-phase LC-MS/MS studies. The tedious aspect of manually developing and processing MRM assays involving thousands of transitions has spurred to development of software tools to automate this process. Software packages have been developed for project management, assay development, assay validation, data export, peak integration, quality assessment, and biostatistical analysis. No single tool provides a complete end-to-end solution, thus this article reviews the current state and discusses future directions of these software tools in order to enable researchers to combine these tools for a comprehensive targeted proteomics workflow. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.
Glycoproteins Enrichment and LC-MS/MS Glycoproteomics in Central Nervous System Applications.
Zhu, Rui; Song, Ehwang; Hussein, Ahmed; Kobeissy, Firas H; Mechref, Yehia
2017-01-01
Proteins and glycoproteins play important biological roles in central nervous systems (CNS). Qualitative and quantitative evaluation of proteins and glycoproteins expression in CNS is critical to reveal the inherent biomolecular mechanism of CNS diseases. This chapter describes proteomic and glycoproteomic approaches based on liquid chromatography/tandem mass spectrometry (LC-MS or LC-MS/MS) for the qualitative and quantitative assessment of proteins and glycoproteins expressed in CNS. Proteins and glycoproteins, extracted by a mass spectrometry friendly surfactant from CNS samples, were subjected to enzymatic (tryptic) digestion and three down-stream analyses: (1) a nano LC system coupled with a high-resolution MS instrument to achieve qualitative proteomic profile, (2) a nano LC system combined with a triple quadrupole MS to quantify identified proteins, and (3) glycoprotein enrichment prior to LC-MS/MS analysis. Enrichment techniques can be applied to improve coverage of low abundant glycopeptides/glycoproteins. An example described in this chapter is hydrophilic interaction liquid chromatographic (HILIC) enrichment to capture glycopeptides, allowing efficient removal of peptides. The combination of three LC-MS/MS-based approaches is capable of the investigation of large-scale proteins and glycoproteins from CNS with an in-depth coverage, thus offering a full view of proteins and glycoproteins changes in CNS.
Fang, Jing; Wu, Qian; Zhao, Yun; Zhao, Hongzhi; Xu, Shunqing; Cai, Zongwei
2017-01-01
Gas chromatography-triple quadrupole mass spectrometry (GC-QqQMS) was applied for the determination of eight organochlorine pesticides (OCPs) in human serum. OCPs were extracted from the serum sample by solid phase extraction (SPE) and analyzed by gas chromatography mass spectrometry (GC-MS) or gas chromatography tandem mass spectrometry (GC-MS/MS). Electron ionization (EI) and negative chemical ionization (NCI) under two data acquisition modes, namely selected ion monitoring (SIM) and multiple reaction monitoring (MRM), were compared. The use of MRM generally provided higher selectivity and sensitivity because less interference from the sample matrix existed. The EI mode is more suitable for less electronegative compounds such as dichlorodiphenyldichloroethanes (DDDs) with detection limits ranging from 0.0060 to 0.060ng/mL. In the NCI mode, MRM analysis provided good and lower detection limits (0.0011-0.0030ng/mL) for pesticides containing more chlorines. The methods were validated by analyzing the pesticides in spiked serum at different levels with recoveries ranged from 83% to 116% and relative standard deviations of less than 10%. The developed method was applied for the determination of the OCPs in real human serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Alshogran, Osama Y; Ocque, Andrew J; Leblond, François A; Pichette, Vincent; Nolin, Thomas D
2016-04-01
A simple and rapid liquid chromatographic-tandem mass spectrometric method has been developed and validated for the enantiospecific determination of R- and S-warfarin in human urine. Warfarin enantiomers were extracted from urine using methyl tert-butyl ether. Chromatographic separation of warfarin enantiomers and the internal standard d5-warfarin was achieved using a Astec Chirobiotic V column with gradient mobile phase at a flow rate of 400 µL/min over 10 min. Detection was performed on a TSQ Quantum Ultra triple quadrupole mass spectrometer equipped with a heated electrospray ionization source. Analytes were detected in negative ionization mode using selected reaction monitoring. Calibration curves were linear with a correlation coefficient of ≥0.996 for both enantiomers over a concentration range of 5-500 ng/mL. The intra- and interday accuracy and precision for both analytes were within ±9.0%. Excellent extraction efficiency and negligible matrix effects were observed. The applicability of the method was demonstrated by successful measurement of warfarin enantiomers in urine of patients with kidney disease. The method is simple, accurate and reproducible and is currently being used to support warfarin pharmacokinetic studies. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Vanol, Pravin G; Sanyal, Mallika; Shah, Priyanka A; Shrivastav, Pranav S
2018-03-23
A highly sensitive, selective and rugged method has been described for the quantification of metronidazole (MTZ) in human plasma by liquid chromatography-tandem mass spectrometry using metronidazole-d4 as the internal standard (IS). The analyte and the IS were extracted from 100 μL plasma by liquid-liquid extraction. The clear samples obtained were chromatographed on an ACE C 18 (100 × 4.6 mm, 5 μm) column using acetonitrile and 10.0 mm ammonium formate in water, pH 4.00 (80:20, v/v) as the mobile phase. A triple quadrupole mass spectrometer system equipped with turbo ion spray source and operated in multiple reaction monitoring mode was used for the detection and quantification of MTZ. The calibration range was established from 0.01 to 10.0 μg/mL. The results of validation testing for precision and accuracy, selectivity, matrix effects, recovery and stability complied with current bioanalytical guidelines. A run time of 3.0 min permitted analysis of more than 300 samples in a day. The method was applied to a bioequivalence study with 250 mg MTZ tablet formulation in 24 healthy Indian males. Copyright © 2018 John Wiley & Sons, Ltd.
Priego Capote, Feliciano; Jiménez, José Ruiz; Granados, José María Mata; de Castro, María Dolores Luque
2007-01-01
A method for determination of fat-soluble vitamins K(1), K(3), A, D(2), D(3) and E (as alpha- and delta-tocopherol) and metabolites 25-hydroxyvitamin D(2) and D(3) and 1,25-dihydroxyvitamin D(3) in human serum by liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) in positive mode is proposed. Highly selective identification of the target compounds in serum was confirmed by the most representative transitions from precursor ion to product ion. Quantitative MS/MS analysis was carried out by multiple reaction monitoring optimizing the most sensitive transition for each analyte in order to achieve low detection limits (from 0.012 to 0.3 ng/mL estimated with serum). The analysis was performed with 1 mL of serum, which was subjected to protein precipitation, liquid-liquid extraction to an organic phase, evaporation to dryness and reconstitution with methanol. The precision of the overall method ranged from 3.17-6.76% as intra-day variability and from 5.07-11.53% as inter-day variability. The method, validated by the standard addition method, provides complete information on the fat-soluble vitamins profile, which is of interest in clinical and metabolomics studies.
Angeloni, Simone; Navarini, Luciano; Sagratini, Gianni; Torregiani, Elisabetta; Vittori, Sauro; Caprioli, Giovanni
2018-06-20
Lignans are polyphenolic compounds that are considered phytoestrogens for their plant origins and they possess different biological activities. Three different extraction methods, i.e., 'dilute and shoot', acidic hydrolysis and enzymatic digestion, have been compared for extracting lignans (secoisolariciresinol, SECO, matairesinol, MAT and lariciresinol LARI) from espresso coffee (EC) by using high performance liquid chromatography (HPLC) tandem mass spectrometry (MS/MS). The best recovery values (SECO: 97%, LARI: 98% and MAT: 93%) were obtained by using enzymatic hydrolysis with Clara-Diastase at 10% (w/v), keeping the sample at 37 °C for 3 hours. For this reason, this method has been chosen and then applied to quantify lignans in nine different EC samples from five different geographical origins (Brazil, Colombia, El Salvador, Ethiopia and India). SECO and LARI were found in all EC samples from 27.9 to 52.0 μg l -1 and from 5.3 to 27.8 μg l -1 , respectively, contrary to MAT that it was not possible to detect it in each type of coffee. This method confirms the high specificity and sensitivity of MS/MS system for detecting bioactives in complex matrix such as coffee. This article is protected by copyright. All rights reserved.
Fuentes, Edwar; Báez, María E; Díaz, Juan
2009-12-18
An effective extraction method was devised for the determination of organophosphorus pesticides (OPPs) in olive and avocado oil samples, using atmospheric pressure microwave-assisted liquid-liquid extraction (APMAE) and solid-phase extraction or low-temperature precipitation as clean-up step. A simple glass system equipped with an air-cooled condenser was designed as an extraction vessel. The pesticides were partitioned between acetonitrile and oil solution in hexane. Analytical determinations were carried out by gas chromatography-flame photometric detection and gas chromatography-tandem mass spectrometry, using a triple quadrupole mass analyzer, for confirmation purposes. Several factors influencing the extraction efficiency were investigated and optimized through fractional factorial design and Doehlert design. Under optimal conditions the recovery of pesticides from oil at 0.025 microg g(-1) ranged from 71% to 103%, except for fenthion in avocado oil, with RSDs < or = 13% (n=5). The LOQ for the entire method ranged from 0.004 to 0.015 microg g(-1). Finally, the proposed method was successfully applied to the extraction and determination of the selected pesticides in 20 commercially packed extra virgin olive oils and four commercially packed avocado oils produced in Chile. Detectable residues of different OPPs were observed in 85% of samples.
Seraglio, Siluana Katia Tischer; Valese, Andressa Camargo; Daguer, Heitor; Bergamo, Greici; Azevedo, Mônia Stremel; Gonzaga, Luciano Valdemiro; Fett, Roseane; Costa, Ana Carolina Oliveira
2016-09-01
A simple, reproducible and sensitive method has been optimized and validated for simultaneous determination of 32 phenolic compounds in bracatinga (Mimosa scabrella Benth.) with the diluted-and-shoot approach, without the need of any additional clean-up steps. It has been based on high performance liquid chromatography coupled with triple quadrupole tandem mass spectrometry and electrospray ionization (HPLC-ESI-MS/MS). The chromatography conditions were optimized, and due to the selectivity provided by MRM monitoring, LC separation required only 9min. The developed method was validated on the basis of Eurachem and European Commission Decision 2002/657/EC guidelines. Mean recoveries ranged from 70.4 to 110%. Intra-day and inter-day precision with RSD (relative standard deviations) from 0.14 to 18.9% and 0.34 to 20.0%, respectively were achieved. Limits of detection (LOD) and quantification (LOQ) ranged from 0.03 to 3.20μgL -1 and 0.20-12.8μgL -1 . Finally, the method was applied to samples and 20 phenolic compounds were quantified in all the samples analyzed, representing a contribution to the characterization and quantification of phenolic compounds from bracatinga (M. scabrella Bentham) honeydew honey. Copyright © 2016 Elsevier Ltd. All rights reserved.
Chandra, Preeti; Kannujia, Rekha; Saxena, Ankita; Srivastava, Mukesh; Bahadur, Lal; Pal, Mahesh; Singh, Bhim Pratap; Kumar Ojha, Sanjeev; Kumar, Brijesh
2016-09-10
An ultra-high performance liquid chromatography electrospray ionization tandem mass spectrometry method has been developed and validated for simultaneous quantification of six major bioactive compounds in five varieties of Withania somnifera in various plant parts (leaf, stem and root). The analysis was accomplished on Waters ACQUITY UPLC BEH C18 column with linear gradient elution of water/formic acid (0.1%) and acetonitrile at a flow rate of 0.3mLmin(-1). The proposed method was validated with acceptable linearity (r(2), 0.9989-0.9998), precision (RSD, 0.16-2.01%), stability (RSD, 1.04-1.62%) and recovery (RSD ≤2.45%), under optimum conditions. The method was also successfully applied for the simultaneous determination of six marker compounds in twenty-six marketed formulations. Hierarchical cluster analysis and principal component analysis were applied to discriminate these twenty-six batches based on characteristics of the bioactive compounds. The results indicated that this method is advance, rapid, sensitive and suitable to reveal the quality of Withania somnifera and also capable of performing quality evaluation of polyherbal formulations having similar markers/raw herbs. Copyright © 2016 Elsevier B.V. All rights reserved.
Barco, Sebastiano; Castagnola, Elio; Moscatelli, Andrea; Rudge, James; Tripodi, Gino; Cangemi, Giuliana
2017-10-25
In this paper we show the development and validation of a volumetric absorptive microsampling (VAMS™)-LC-MS/MS method for the simultaneous quantification of four antibiotics: piperacillin-tazobactam, meropenem, linezolid and ceftazidime in 10μL human blood. The novel VAMS-LC-MS/MS method has been compared with a dried blood spot (DBS)-based method in terms of impact of hematocrit (HCT) on accuracy, reproducibility, recovery and matrix effect. Antibiotics were extracted from VAMS and DBS by protein precipitation with methanol after a re-hydration step at 37°C for 10min. LC-MS/MS was carried out on a Thermo Scientific™ TSQ Quantum™ Access MAX triple quadrupole coupled to an Accela ™UHPLC system. The VAMS-LC-MS/MS method is selective, precise and reproducible. In contrast to DBS, it allows an accurate quantification without any HCT influence. It has been applied to samples derived from pediatric patients under therapy. VAMS is a valid alternative sampling strategy for the quantification of antibiotics and is valuable in support of clinical PK/PD studies and consequently therapeutic drug monitoring (TDM) in pediatrics. Copyright © 2017 Elsevier B.V. All rights reserved.
Pérez, Rosa Ana; Albero, Beatriz; Tadeo, José Luis; Sánchez-Brunete, Consuelo
2016-11-01
A rapid extraction procedure is presented for the determination of five endocrine-disrupting compounds, estrone, ethinylestradiol, bisphenol A, triclosan, and 2-ethylhexylsalicylate, in water samples. The analysis involves a two-step extraction procedure that combines dispersive liquid-liquid microextraction (DLLME) with dispersive micro-solid phase extraction (D-μ-SPE), using magnetic nanoparticles, followed by in situ derivatization in the injection port of a gas chromatograph coupled to triple quadrupole mass spectrometry. The use of uncoated or oleate-coated Fe 3 O 4 nanoparticles as sorbent in the extraction process was evaluated and compared. The main parameters involved in the extraction process were optimized applying experimental designs. Uncoated Fe 3 O 4 nanoparticles were selected in order to simplify and make more cost-effective the procedure. DLLME was carried out at pH 3, during 2 min, followed by the addition of the nanoparticles for D-μ-SPE employing 1 min in the extraction. Analysis of spiked water samples of different sources gave satisfactory recovery results for all the compounds with detection limits ranging from 7 to 180 ng l -1 . Finally, the procedure was applied in tap, well, and river water. Graphical abstract Diagram of the extraction method using magnetic nanoparticles (MNPs).
Mistri, Hiren N; Jangid, Arvind G; Pudage, Ashutosh; Shrivastav, Pranav
2008-03-15
A simple, selective and sensitive isocratic HPLC method with triple quadrupole mass spectrometry detection has been developed and validated for simultaneous quantification of zopiclone and its metabolites in human plasma. The analytes were extracted using solid phase extraction, separated on Symmetry shield RP8 column (150 mm x 4.6 mm i.d., 3.5 microm particle size) and detected by tandem mass spectrometry with a turbo ion spray interface. Metaxalone was used as an internal standard. The method had a chromatographic run time of 4.5 min and linear calibration curves over the concentration range of 0.5-150 ng/mL for both zopiclone and N-desmethyl zopiclone and 1-150 ng/mL for zopiclone-N-oxide. The intra-batch and inter-batch accuracy and precision evaluated at lower limit of quantification and quality control levels were within 89.5-109.1% and 3.0-14.7%, respectively, for all the analytes. The recoveries calculated for the analytes and internal standard were > or = 90% from spiked plasma samples. The validated method was successfully employed for a comparative bioavailability study after oral administration of 7.5 mg zopiclone (test and reference) to 16 healthy volunteers under fasted condition.
Walorczyk, Stanisław; Drożdżyński, Dariusz; Kowalska, Jolanta; Remlein-Starosta, Dorota; Ziółkowski, Andrzej; Przewoźniak, Monika; Gnusowski, Bogusław
2013-08-15
A sensitive, accurate and reliable multiresidue method based on the application of gas chromatography-tandem quadrupole mass spectrometry (GC-QqQ-MS/MS) has been established for screening, identification and quantification of a large number of pesticide residues in produce. The method was accredited in compliance with PN-EN ISO/IEC 17025:2005 standard and it was operated under flexible scope as PB-11 method. The flexible scope of accreditation allowed for minor modifications and extension of the analytical scope while using the same analytical technique. During the years 2007-2010, the method was used for the purpose of verification of organic crop production by multiresidue analysis for the presence of pesticides. A total of 528 samples of differing matrices such as fruits, vegetables, cereals, plant leaves and other green parts were analysed, of which 4.4% samples contained pesticide residues above the threshold value of 0.01 mg/kg. A total of 20 different pesticide residues were determined in the samples. Copyright © 2013 Elsevier Ltd. All rights reserved.
Hwang, Taeik; Noh, Eunyoung; Jeong, Ji Hye; Park, Sung-Kwan; Shin, Dongwoo; Kang, Hoil
2018-02-28
A sensitive and specific high-performance liquid chromatography-quadrupole time-of-flight-mass spectrometry (LC-QTOF-MS) method combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the determination of grayanotoxins I and III in dietary supplements and homemade wine. Grayanotoxins I and III were successfully extracted using solid-phase extraction cartridges, characterized by LC-QTOF-MS, and quantitated by LC-MS/MS. The LC-MS/MS calibration curves were linear over concentrations of 10-100 ng/mL (grayanotoxin I) and 20-400 ng/mL (grayanotoxin III). Grayanotoxins I and III were found in 51 foodstuffs, with quantitative determinations revealing total toxin concentrations of 18.4-101 000 ng/mL (grayanotoxin I) and 15.3-56 000 ng/mL (grayanotoxin III). The potential of the validated method was demonstrated by successful quantitative analysis of grayanotoxins I and III in dietary supplements and homemade wine; the method appears suitable for the routine detection of grayanotoxins I and III from Rhododendron brachycarpum.
1982-07-15
structural information contained in deuterated sp ies is readily obtainable. Eth 1 ions ty stdied tnc) Vde (CH3CHOH?’., [CH CHOHJ. (CH2COH]r-% [CH 2COF...high and low energy systems involves electronic 18 and vibrational 19 excitation respectively, the amount of energy thus deposited must be approximately
An analytical method to identify and quantify trace levels of C5 to C12 perfluorocarboxylic acids (PFCAs) in articles of commerce (AOC) is developed and rigorously validated. Solid samples were extracted in methanol, and liquid samples were diluted with a solvent consisting of 60...
NASA Astrophysics Data System (ADS)
Andres-Costa, M. Jesus; Andreu, Vicente; Picó, Yolanda
2016-04-01
The presence of drugs of abuse in the aquatic environment has been recognized as an important issue for the ecosystem due their possible negative effect on it (Richardson, 2011). Incomplete removal of these substances during wastewater treatment could be one of the causes of their release in the environment (Zuccato and Castiglioni, 2009). Pollution by illicit drug residues at very low concentrations is generalized in populated areas, with potential risks for human health and the environment (Zuccato, 2008; Castiglioni et al 2007).The aim of this study was to screen and quantify 44 drugs of abuse and metabolites of wastewater samples using a hybrid quadrupole time-of-flight tandem mass spectrometry and furthermore carry out a post-target screening to identify additional compounds present in the water samples. Wastewater samples were collected from the influent and effluent of three wastewater treatment plants (WWTPs) in Valencia and river water samples form Turia River Basin. Illicit drugs were extracted by solid-phase extraction (SPE). The chromatography was performed with an Agilent 1260 Infinity ultra high performance liquid chromatography (UHPLC). The UHPLC system was coupled to a hybrid quadrupole time-of-flight ABSciex Triple TOFTM 5600. All analytes were analyzed in positive mode. Acquiring full scan MS data was employed for quantification of drugs of abuse, and automatic data dependent information product ion spectra (IDA-MS/MS) was checked for identifying emerging illicit drugs and other compounds in water samples. The use of a database containing 1212 compounds achieved high confidence results for a wide number of contaminants. In the present study, the presence of compounds that belong to amphetamines group (amphetamine, methamphetamine, ephedrine, MDMA, MDA and MDEA), tryptamines (bufotenine), pirrolidinophenone group (α-PVP and 4'-MePHP), arylcyclohexylamines (ketamine), cocainics (cocaine, benzoylecgonine, cocaethylene and ecgonine methyl ester) and morphine derivatives (codeine, EDDP, morphine and methadone) and cannabinoids (THC) were detected in the influent, effluent or river water samples. These compounds were quantified, reaching cocainics and morphine derivates the highest values. Regarding post-target screening approach, more than 120 contaminants, mostly pharmaceuticals, but also mycotoxins and polyphenols were unambiguously identified. This new approach to data evaluation by non-target screening analyses opens the possibility of various other applications, for example in open and groundwater or for monitoring natural attenuation. Acknowledgements This work has been supported by the Spanish Ministry of Economy and Competitiveness trough the project CGL 2011-29703-C02-02. MJ Andrés Costa also acknowledges to this Ministry the FPI grant to perform her PhD. References Castiglioni S, Zuccato E. Chiabrando C., Faneli R., Bagnati R. Spectroscopy Europe (2007), 19, 7-9. Richardson SD. Anal Chem (2011), 84, 747-778. Zuccato E., Castiglioni S. Philos Trans R Soc A (2009), 367, 3965-3978. Zuccato E., Castiglioni S., Bagnati, R., Chiabrando C., Grassi P., Fanelli R. Water Res (2008), 42, 961-968.
Elmongy, Hatem; Ahmed, Hytham; Wahbi, Abdel-Aziz; Amini, Ahmad; Colmsjö, Anders; Abdel-Rehim, Mohamed
2016-08-01
A sensitive, accurate and reliable bioanalytical method for the enantioselective determination of metoprolol in plasma and saliva samples utilizing liquid chromatography-electrospray ionization tandem mass spectrometry was developed and validated. Human plasma and saliva samples were pretreated by microextraction by packed sorbent (MEPS) prior to analysis. A new MEPS syringe form with two inputs was used. Metoprolol enantiomers and internal standard pentycaine (IS) were eluted from MEPS sorbent using isopropanol after removal of matrix interferences using aliquots of 5% methanol in water. Complete separation of metoprolol enantiomers was achieved on a Cellulose-SB column (150 × 4.6 mm, 5 μm) using isocratic elution with mobile phase 0.1% ammonium hydroxide in hexane-isopropanol (80:20, v/v) with a flow rate of 0.8 mL/min. A post-column solvent-assisted ionization was applied to enhance metoprolol ionization signal in positive mode monitoring (+ES) using 0.5% formic acid in isopropanol at a flow rate of 0.2 mL/min. The total chromatographic run time was 10 min for each injection. The detection of metoprolol in plasma and saliva samples was performed using triple quadrupole tandem mass spectrometer in +ES under the following mass transitions: m/z 268.08 → 72.09 for metoprolol and m/z 303.3 → 154.3 for IS. The linearity range was 2.5-500 ng/mL for both R- and S-metoprolol in plasma and saliva. The limits of detection and quantitation for both enantiomers were 0.5 and 2.5 ng/mL respectively, in both matrices (plasma and saliva). The intra- and inter-day precisions were presented in terms of RSD values for replicate analysis of quality control samples and were <5%; the accuracy of determinations varied from 96 to 99%. The method was able to determine the therapeutic levels of metoprolol enantiomers in both human plasma and saliva samples successfully, which can aid in therapeutic drug monitoring in clinical laboratories. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Kang, Ju Hui; Jung, Hyun Jeong; Jung, Mun Yhung
2016-08-31
We developed a new fast and selective analytical method for the determination of inorganic arsenic (iAs) in rice by a gas chromatography - tandem mass spectrometry (GC-MS/MS) in combination with one step derivatization of inorganic arsenic (iAs) with British Anti-Lewsite (BAL). Two step derivatization of iAs with BAL has been previously performed for the GC-MS analysis. In this paper, the quantitative one step derivatization condition was successfully established. The GC-MS/MS was carried out with a short nonpolar capillary column (0.25 mm × 10 m) under the conditions of fast oven temperature ramp rate (4 °C/s) and high linear velocity (108.8 cm/s) of the carrier gas. The established GC-MS/MS method showed an excellent linearity (r(2) > 0.999) in a tested range (0.2-100.0 μg L(-1)), ultra-low limit of detection (LOD, 0.08 pg), and high precision and accuracy. The GC-MS/MS technique showed far greater selectivity (22.5 fold higher signal to noise ratio in rice sample) on iAs than GC-MS method. The gas chromatographic running time was only 2.5 min with the iAs retention time of 1.98 min. The established method was successfully applied to quantify the iAs contents in polished rice. The mean iAs content in the Korean polished rice (n = 27) was 66.1 μg kg(-1) with the range of 37.5-125.0 μg kg(-1). This represents the first report on the GC-tandem mass spectrometry in combination with the one step derivatization with BAL for the iAs speciation in rice. This GC-MS/MS method would be a simple, useful and reliable measure for the iAs analysis in rice in the laboratories in which the expensive and element specific HPLC-ICP-MS is not available. Copyright © 2016 Elsevier B.V. All rights reserved.
Shelver, Weilin L; Hakk, Heldur; Larsen, Gerald L; DeSutter, Thomas M; Casey, Francis X M
2010-02-19
An analytical method was developed using ultra-high-pressure liquid chromatography-triple quadrupole-tandem mass spectrometry (UHPLC-TQ-MS/MS) to simultaneously analyze 14 sulfonamides (SA) in 6 min. Despite the rapidity of the assay the system was properly re-equilibrated in this time. No carryover was observed even after high analyte concentrations. The instrumental detection limit based on signal-to-noise ratio (S/N)>3, was below 1 pg/microL (5 pg on column) for all SAs except sulfachloropyridazine. Surface water, ground water, soil, and slurry manure contained in storage ponds in and around swine [Sus scrofa domesticus] rearing facilities were analyzed. Sample cleanup for ground water and surface water included using solid phase extraction (SPE) using Oasis hydrophilic-lipophilic balance (HLB) cartridges. The soil and slurry manure required tandem strong anion exchange (SAX) and HLB solid phase extraction cartridges for sample cleanup. With few exceptions, the recoveries ranged from 60 to 100% for all matrices. The minimum detectable levels were below 2.0 ng/L for water, 30 ng/L for slurry manure, and 45 ng/kg for soil except for sulfachloropyridazine. The coefficient of variation (CV) was within 20% for most of the compounds analyzed. Using this method, sulfamethazine concentrations of 2250-5060 ng/L, sulfamethoxazole concentrations of 108-1.47 x 10(6)ng/L, and sulfathiazole concentrations of 785-1700 ng/L were found in the slurry manure. Sulfadimethoxine (2.0-32 ng/L), sulfamethazine (2.0-5.1 ng/L), and sulfamethoxazole (20.5-43.0 ng/L) were found in surface water and ground water. In top soil (0-15 cm), sulfamethazine ranged 34.5-663 ng/kg dry weight in those locations that received slurry manure as a nutrient; no SAs were found in the soil depths between 46 and 61 cm. The speed makes the method practical for medium to high throughput applications. The sensitivity and positive analyte identification make the method suitable for the demanding requirements for real world applications. Published by Elsevier B.V.
USDA-ARS?s Scientific Manuscript database
RATIONALE: Previously we have reported a liquid chromatography tandem mass spectrometry method for the identification and quantification of regulated veterinary drugs. The methods used three selected transition ions but most of these ions lacked structural characterization. The work presented here ...
Chu, Wenhai; Gao, Naiyun; Yin, Daqiang; Krasner, Stuart W; Templeton, Michael R
2012-04-27
The haloacetamides (HAcAms) are disinfection by-products (DBPs) in drinking water which are currently receiving increased scientific attention due to their elevated toxicity relative to regulated disinfection by-products. A simultaneous determination method of 13 HAcAms, combining solid-phase extraction (SPE) enrichment, liquid chromatographic (LC) separation, and triple quadrupole mass spectrometry (tqMS) detection with atmospheric pressure chemical ionization (APCI) using selective reaction monitoring in positive mode, was developed to measure HAcAms, including chlorinated, brominated, and iodinated analogs. Ammonium chloride and Oasis HLB were selected as the dechlorinating reagent and polymeric SPE sorbent of HAcAm samples. The used tqMS apparatus showed higher sensitivity for the studied HAcAms in the APCI mode than electrospray ionization. 13 HAcAms were separated by LC in 9.0 min, and the detection limits ranged from 7.6 to 19.7 ng/L. The SPE-LC/tqMS method was successfully applied to quantify 13 HAcAms in drinking water samples for the first time, and first indentified tribromoacetamide and chloroiodoacetamide as DBPs in drinking water. Copyright © 2012 Elsevier B.V. All rights reserved.
Hurtado-Gaitán, Elías; Sellés-Marchart, Susana; Martínez-Márquez, Ascensión; Samper-Herrero, Antonio; Bru-Martínez, Roque
2017-03-07
Grapevine stilbenes are a family of polyphenols which derive from trans -resveratrol having antifungal and antimicrobial properties, thus being considered as phytoalexins. In addition to their diverse bioactive properties in animal models, they highlight a strong potential in human health maintenance and promotion. Due to this relevance, highly-specific qualitative and quantitative methods of analysis are necessary to accurately analyze stilbenes in different matrices derived from grapevine. Here, we developed a rapid, sensitive, and specific analysis method using ultra-high-performance liquid chromatography coupled to triple-quadrupole mass spectrometry (UHPLC-QqQ) in MRM mode to detect and quantify five grapevine stilbenes, trans -resveratrol, trans -piceid, trans -piceatannol, trans -pterostilbene, and trans -ε-viniferin, whose interest in relation to human health is continuously growing. The method was optimized to minimize in-source fragmentation of piceid and to avoid co-elution of cis -piceid and trans -resveratrol, as both are detected with resveratrol transitions. The applicability of the developed method of stilbene analysis was tested successfully in different complex matrices including cellular extracts of Vitis vinifera cell cultures, reaction media of biotransformation assays, and red wine.
Naccarato, Attilio; Gionfriddo, Emanuela; Elliani, Rosangela; Sindona, Giovanni; Tagarelli, Antonio
2014-10-30
The analysis of characteristic urinary acidic markers such as glutaric, 3-hydroxyglutaric, 2-hydroxyglutaric, adipic, suberic, sebacic, ethylmalonic, 3-hydroxyisovaleric and isobutyric acid constitutes the recommended follow-up testing procedure for glutaric acidemia type 1 (GA-1) and type 2 (GA-2). The goal of the work herein presented is the development of a fast and simple method for the quantification of these biomarkers in human urine. The proposed analytical approach is based on the use of solid phase microextraction (SPME) combined with gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) afterward a rapid derivatization of acidic moieties by propyl chloroformate, propanol and pyridine. Trueness and precision of the proposed protocol, tested at 5, 30 and 80mgl -1 , provided satisfactory values: recoveries were in the range between 72% and 116% and the relative standard deviations (RSD%) were between 0.9% and 18% (except for isobutyric acid at 5mgl -1 ). The LOD values achieved by the proposed method ranged between 1.0 and 473μgl -1 . Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Guo, Ning; Liang, Qimeng; Li, Shuo; Ouyang, Ruizhuo; Lü, Wei
2017-11-01
A family of apatite-type fluorophosphate phosphors with general formula Sr3Gd(1-m-n)Na(PO4)3F:mTb3+,nEu3+ (SGN:mTb3+,nEu3+) have been synthesized via the high-temperature solid-state reaction method. Triple energy transfer processes from Gd3+ in the host to both Tb3+ and Eu3+, as well as from Tb3+ to Eu3+ have been verified by the photoluminescence spectra. Under the excitation of UV light, both green line from the transitions of Tb3+ and red line origin from the transitions of Eu3+ have been simultaneously observed in a single phase phosphor, which makes a promise for tunable color emissions from yellowish-green through yellow and ultimately to reddish-orange by simply adjusting the Eu3+ content (n) in SGN:0.20Tb3+,nEu3+ phosphors. Additionally, the energy transfer from the Tb3+ to the Eu3+ ions has been demonstrated to be a resonant type via a quadrupole-quadrupole mechanism based on the Dexter's theoretical model, and the energy transfer efficiency increases with an increase in Eu3+ concentration.
Abad-García, B; Garmón-Lobato, S; Berrueta, L A; Gallo, B; Vicente, F
2009-07-01
Fifteen flavonoid O-diglycosides with different interglycosidic linkage isomery and glycosylation position have been studied in order to analyze their fragmentation patterns. Initial separation was carried out using high performance liquid chromatography with diode array detection (HPLC/DAD) coupled to an electrospray ionization (ESI) interface and a triple quadrupole mass spectrometer. Some useful differences in their MS spectra have been found and discussed. As it has already been reported, [Y*]+/[Y0]+ ratio for flavanones and [Y1]+/[Y0]+ ratio for other flavonoids is specific for each isomeric interglycosidic linkage. In this work it has also been observed that the abundance of these ions is dependent on the position of glycosylation. On the basis of these differences, systematic guidelines for our experimental conditions have been proposed for the differentiation of not only isomeric interglycosidic linkage but also glycosylation position using collision-induced dissociation MS/MS (CID-MS/MS) spectra in positive mode. These results have been successfully applied for the characterization of three diglycosyl flavonoids found in Citrus fruit juices and these conclusions have also been extrapolated for characterizing two triglycosides in the same fruits. Copyright 2009 John Wiley & Sons, Ltd.
Silva, Eduarda M P; Varandas, Pedro A M M; Melo, Tânia; Barros, Cristina; Alencastre, Inês S; Barreiros, Luísa; Domingues, Pedro; Lamghari, Meriem; Domingues, M Rosário M; Segundo, Marcela A
2018-03-20
Collision induced dissociation of triple quadrupole mass spectrometer (CID-QqQ) and high-energy collision dissociation (HCD) of Orbitrap were compared for four neuropeptides Y Y1 (NPY Y1) receptor antagonists and showed similar qualitative fragmentation and structural information. Orbitrap high resolution and high mass accuracy HCD fragmentation spectra allowed unambiguous identification of product ions in the range 0.04-4.25 ppm. Orbitrap mass spectrometry showed abundant analyte-specific product ions also observed on CID-QqQ. These results show the suitability of these product ions for use in quantitative analysis by MRM mode. In addition, it was found that all compounds could be determined at levels >1 μg L -1 using the QqQ instrument and that the detection limits for this analyzer ranged from 0.02 to 0.6 μg L -1 . Overall, the results obtained from experiments acquired in QqQ show a good agreement with those acquired from the Orbitrap instrument allowing the use of this relatively inexpensive technique (QqQ) for accurate quantification of these compounds in clinical and academic applications. Copyright © 2018 Elsevier B.V. All rights reserved.
Evidence and quantitation of aromatic organosulfates in ambient aerosols in Lahore, Pakistan
NASA Astrophysics Data System (ADS)
Kundu, S.; Quraishi, T. A.; Yu, G.; Suarez, C.; Keutsch, F. N.; Stone, E. A.
2013-05-01
Organosulfates are important components of atmospheric organic aerosols, yet their structures, abundances, sources and formation processes are not adequately understood. This study presents the identification and quantitation of benzyl sulfate in atmospheric aerosols, which is the first confirmed atmospheric organosulfate with aromatic carbon backbone. Benzyl sulfate was identified and quantified in fine particulate matter (PM2.5) collected in Lahore, Pakistan, during 2007-2008. An authentic standard of benzyl sulfate was synthesized, standardized, and identified in atmospheric aerosols with quadrupole time-of-flight (Q-ToF) mass spectrometry (MS). Benzyl sulfate was quantified in aerosol samples using ultra performance liquid chromatography (UPLC) coupled to negative electrospray ionization triple quadrupole (TQ) MS. The highest benzyl sulfate concentrations were recorded in November and January 2007 (0.50 ± 0.11 ng m-3) whereas the lowest concentration was observed in July (0.05 ± 0.02 ng m-3). To evaluate matrix effects, benzyl sulfate concentrations were determined using external calibration and the method of standard addition; comparable concentrations were detected by the two methods, which ruled out significant matrix effects in benzyl sulfate quantitation. Three additional organosulfates with m/z 187, 201 and 215 were qualitatively identified as aromatic organosulfates with additional methyl substituents by high-resolution mass measurements and tandem MS. The observed aromatic organosulfates form a homologous series analogous to toluene, xylene, and trimethylbenzene, which are abundant anthropogenic volatile organic compounds (VOC), suggesting that aromatic organosulfates may be formed by secondary reactions. However, stronger statistical correlations of benzyl sulfate with combustion tracers (EC and levoglucosan) than with secondary tracers (SO42- and α-pinene-derived nitrooxy organosulfates) suggest that aromatic organosulfates may be emitted from the combustion sources or their subsequent atmospheric processing. Further studies are needed to elucidate the sources and formation pathways of aromatic organosulfates in the atmosphere.
Yang, Yang; Wang, Hong-Jie; Yang, Jian; Brantner, Adelheid H; Lower-Nedza, Agnieszka D; Si, Nan; Song, Jian-Fang; Bai, Bing; Zhao, Hai-Yu; Bian, Bao-Lin
2013-12-20
To clarify and quantify the chemical profiling of Huang-Lian-Jie-Du decoction (HLJDD) rapidly, a feasible and accurate strategy was developed by applying high speed LC combined with hybrid quadrupole-orbitrap mass spectrometer (Q-Exactive) and UHPLC-triple quadruple mass spectrometer (UHPLC-QqQ MS). 69 compounds, including iridoids, alkaloids, flavonoids, triterpenoid, monoterpene and phenolic acids, were identified by their characteristic high resolution mass data. Among them, 18 major compounds were unambiguously detected by comparing with reference standards. In the subsequent quantitative analysis, 17 representative compounds, selected as quality control markers, were simultaneously detected in 10 batches of HLJDD samples by UHPLC-QqQ MS. These samples were collected from four different countries (regions). Icariin, swertiamarin and corynoline were employed as internal standards for flavonoids, iridoids and alkaloids respectively. All the analytes were detected within 12min. Polarity switching mode was used in the optimization of multiple reaction monitoring (MRM) conditions. Satisfactory linearity was achieved with wide linear range and fine determination coefficient (r(2)>0.9990). The relative standard deviations (RSD) of inter- and intra-day precisions were less than 5.0%. This method was also validated by repeatability, stability (8h) and recovery, with respective RSDs less than 4.6%, 5.0% and 6.3%. This research established a high sensitive and efficient method for the integrating quality control, including identification and quantification of Chinese medicinal formulas. Copyright © 2013 Elsevier B.V. All rights reserved.
Ma, Xiaoxi; Tang, Jijun; Li, Chunzheng; Liu, Qin; Chen, Jia; Li, Hua; Guo, Lei; Xie, Jianwei
2014-08-01
Ricin is a toxic protein derived from castor beans and composed of a cytotoxic A chain and a galactose-binding B chain linked by a disulfide bond, which can inhibit protein synthesis and cause cell death. Owing to its high toxicity, ease of preparation, and lack of medical countermeasures, ricin has been listed as both chemical and biological warfare agents. For homeland security or public safety, the unambiguous, sensitive, and rapid methods for identification and quantification of ricin in complicated matrices are of urgent need. Mass spectrometric analysis, which provides specific and sensitive characterization of protein, can be applied to confirm and quantify ricin. Here, we report a liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method in which ricin was extracted and enriched from serum by immunocapture using anti-ricin monoclonal antibody 3D74 linked to magnetic beads, then digested by trypsin, and analyzed by LC-ESI-MS/MS. Among 19 distinct peptides observed in LC-quadrupole/time of flight-MS (LC-QTOF-MS), two specific and sensitive peptides, T7A ((49)VGLPINQR(56)) and T14B ((188)DNCLTSDSNIR(198)), were chosen, and a highly sensitive determination of ricin was established in LC-triple quadrupole-MS (LC-QqQ-MS) operating in multiple reaction monitoring mode. These specific peptides can definitely distinguish ricin from the homologous protein Ricinus communis agglutinin (RCA120), even though the amino acid sequence homology of the A-chain of ricin and RCA120 is up to ca. 93% and that of B-chain is ca. 85%. Furthermore, peptide T7A was preferred in the quantification of ricin because its sensitivity was at least one order of magnitude higher than that of the peptide T14B. Combined with immunocapture enrichment, this method provided a limit of detection of ca. 2.5 ng/mL and the limit of quantification was ca. 5 ng/mL of ricin in serum, respectively. Both precision and accuracy of this method were determined and the RSD was less than 15%. This established method was then applied to measure ricin in serum samples collected from rats exposed to ricin at the dosage of 50 μg/kg in an intravenous injection manner. The results showed that ca. 10 ng/mL of the residual ricin in poisoned rats serum could be detected even at 12 h after exposure.
USDA-ARS?s Scientific Manuscript database
RATIONALE: Analysis for identification and quantification of regulated veterinary drug residues in foods are usually achieved by liquid chromatography coupled to tandem mass spectrometry. The instrument method requires the selection of characteristic ions, but structure elucidation is seldom perform...
Rotander, Anna; Kärrman, Anna; Toms, Leisa-Maree L; Kay, Margaret; Mueller, Jochen F; Gómez Ramos, María José
2015-02-17
Fluorinated surfactant-based aqueous film-forming foams (AFFFs) are made up of per- and polyfluorinated alkyl substances (PFAS) and are used to extinguish fires involving highly flammable liquids. The use of perfluorooctanesulfonic acid (PFOS) and other perfluoroalkyl acids (PFAAs) in some AFFF formulations has been linked to substantial environmental contamination. Recent studies have identified a large number of novel and infrequently reported fluorinated surfactants in different AFFF formulations. In this study, a strategy based on a case-control approach using quadrupole time-of-flight tandem mass spectrometry (QTOF-MS/MS) and advanced statistical methods has been used to extract and identify known and unknown PFAS in human serum associated with AFFF-exposed firefighters. Two target sulfonic acids [PFOS and perfluorohexanesulfonic acid (PFHxS)], three non-target acids [perfluoropentanesulfonic acid (PFPeS), perfluoroheptanesulfonic acid (PFHpS), and perfluorononanesulfonic acid (PFNS)], and four unknown sulfonic acids (Cl-PFOS, ketone-PFOS, ether-PFHxS, and Cl-PFHxS) were exclusively or significantly more frequently detected at higher levels in firefighters compared to controls. The application of this strategy has allowed for identification of previously unreported fluorinated chemicals in a timely and cost-efficient way.
He, Mingzhen; Jia, Jia; Li, Junmao; Wu, Bei; Huang, Wenping; Liu, Mi; Li, Yan; Yang, Shilin; Ouyang, Hui; Feng, Yulin
2018-06-15
Efficient targeted identification of chemical constituents from traditional Chinese medicine is still a major challenge. In this study, we used a characteristic ion filtering strategy to characterize compounds of Eucommia ulmoides Oliv. by ultra-high performance liquid chromatography quadrupole time of flight tandem mass spectrometry (UHPLC-ESI-Q-TOF-MS/MS). By using the ion filtering approach, target constituents of Eucommia ulmoides Oliv. were easily tentatively identified from the enormous LC/MS data set. The strategy consisted of the following three steps: 1) To establishing a characteristic ion database by diagnostic product ions or neutral loss fragments; 2) To evaluate the structural information of the compounds by high-resolution diagnostic characteristic ion filtering; 3) To confirm the different classes by chemical profiling according to their MS/MS spectra. In this study, characteristic ions are summarized as five major groups of compounds in Eucommia ulmoides Oliv. In total, 113 compounds were tentatively identified, including 23 potentially novel compounds. The results form a foundation for the quality control and chemical basis of Eucommia ulmoides Oliv. Copyright © 2018 Elsevier B.V. All rights reserved.
Sanz, Miriam; Andreote, Ana Paula Dini; Fiore, Marli Fatima; Dörr, Felipe Augusto; Pinto, Ernani
2015-01-01
Cyanobacteria from underexplored and extreme habitats are attracting increasing attention in the search for new bioactive substances. However, cyanobacterial communities from tropical and subtropical regions are still largely unknown, especially with respect to metabolite production. Among the structurally diverse secondary metabolites produced by these organisms, peptides are by far the most frequently described structures. In this work, liquid chromatography/electrospray ionization coupled to high resolution quadrupole time-of-flight tandem mass spectrometry with positive ion detection was applied to study the peptide profile of a group of cyanobacteria isolated from the Southeastern Brazilian coastal forest. A total of 38 peptides belonging to three different families (anabaenopeptins, aeruginosins, and cyanopeptolins) were detected in the extracts. Of the 38 peptides, 37 were detected here for the first time. New structural features were proposed based on mass accuracy data and isotopic patterns derived from full scan and MS/MS spectra. Interestingly, of the 40 surveyed strains only nine were confirmed to be peptide producers; all of these strains belonged to the order Nostocales (three Nostoc sp., two Desmonostoc sp. and four Brasilonema sp.). PMID:26096276
USDA-ARS?s Scientific Manuscript database
Veterinary drug residues in animal-derived foods must be monitored to ensure food safety, verify proper veterinary practices, enforce legal limits in domestic and imported foods, and other purposes. A common goal in drug residue analysis in foods is to achieve acceptable monitoring results for as m...
Naccarato, Attilio; Gionfriddo, Emanuela; Sindona, Giovanni; Tagarelli, Antonio
2014-01-31
The work aims at developing a simple and rapid method for the quantification of dopamine (DA), serotonin (5-HT) and norepinephrine (NE) in human urine. The urinary levels of these biogenic amines can be correlated with several pathological conditions concerning heart disease, stress, neurological disorders and cancerous tumors. The proposed analytical approach is based on the use of solid phase microextraction (SPME) combined with gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) after a fast derivatization of both aliphatic amino and phenolic moieties by propyl chloroformate. The variables influencing the derivatization reaction were reliably optimized by the multivariate approach of "Experimental design". The optimal conditions were obtained by performing derivatization with 100μL of propyl chloroformate and 100μL of pyridine. The extraction ability of five commercially available SPME fibers was evaluated in univariate mode and the best results were obtained using the polyacrylate fiber. The variables affecting the efficiency of SPME analysis were again optimized by the multivariate approach of "Experimental design" and, in particular, a central composite design (CCD) was applied. The optimal values were extraction in 45min at room temperature, desorption temperature at 300°C, no addition of NaCl. Assay of derivatized analytes was performed by using a gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) system in selected reaction monitoring (SRM) acquisition. An evaluation of all analytical parameters demonstrates that the developed method provides satisfactory results. Indeed, very good linearities were achieved in the tested calibration range with correlation coefficient values of 0.9995, 0.9999 and 0.9997 for DA, 5-HT and NE, respectively. Accuracies and RSDs calculated for between-run and tested at concentrations of 30, 200, and 800μg L(-1) were in the range from 92.8% to 103.0%, and from 0.67 to 4.5%, respectively. Finally, the LOD values obtained can be considered very good (0.587, 0.381 and 1.23μg L(-1) for DA, 5-HT and NE, respectively). Copyright © 2013 Elsevier B.V. All rights reserved.
Cavaliere, Brunella; Monteleone, Marcello; Naccarato, Attilio; Sindona, Giovanni; Tagarelli, Antonio
2012-09-28
A simple and sensitive method was developed for the quantification of five carbamate pesticides in water samples using solid phase microextraction (SPME) combined with gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS). The performance of five SPME fibers was tested in univariate mode whereas the other variables affecting the efficiency of SPME analysis were optimized by the multivariate approach of design of experiment (DoE) and, in particular, a central composite design (CCD) was applied. The optimum working conditions in terms of response values were achieved by performing analysis with polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber in immersion mode for 45min at room temperature with addition of NaCl (10%). The multivariate chemometric approach was also used to explore the chromatographic behavior of the carbamates and to evaluate the importance of each variable investigated. An overall appraisement of results shows that the factor which gave a statistically significant effect on the response was only the injection temperature. Identification and quantification of carbamates was performed by using a gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) system in multiple reaction monitoring (MRM) acquisition. Since the choice of internal standard represented a crucial step in the development of method to achieve good reproducibility and robustness for the entire analytical protocol, three compounds (2,3,5-trimethacarb, 4-bromo-3,5-dimethylphenyl-n-methylcarbamate (BDMC) and carbaryl-d7) were evaluated as internal standards. Both precision and accuracy of the proposed protocol tested at concentration of 0.08, 5 and 3 μg l⁻¹ offered values ranging from 70.8% and 115.7% (except for carbaryl at 3 μg l⁻¹) and from 1.0% and 9.0% for accuracy and precision, respectively. Moreover, LOD and LOQ values ranging from 0.04 to 1.7 ng l⁻¹ and from 0.64 to 2.9 ng l⁻¹, respectively, can be considered very satisfactory. Copyright © 2012 Elsevier B.V. All rights reserved.
Measuring masses of large biomolecules and bioparticles using mass spectrometric techniques.
Peng, Wen-Ping; Chou, Szu-Wei; Patil, Avinash A
2014-07-21
Large biomolecules and bioparticles play a vital role in biology, chemistry, biomedical science and physics. Mass is a critical parameter for the characterization of large biomolecules and bioparticles. To achieve mass analysis, choosing a suitable ion source is the first step and the instruments for detecting ions, mass analyzers and detectors should also be considered. Abundant mass spectrometric techniques have been proposed to determine the masses of large biomolecules and bioparticles and these techniques can be divided into two categories. The first category measures the mass (or size) of intact particles, including single particle quadrupole ion trap mass spectrometry, cell mass spectrometry, charge detection mass spectrometry and differential mobility mass analysis; the second category aims to measure the mass and tandem mass of biomolecular ions, including quadrupole ion trap mass spectrometry, time-of-flight mass spectrometry, quadrupole orthogonal time-of-flight mass spectrometry and orbitrap mass spectrometry. Moreover, algorithms for the mass and stoichiometry assignment of electrospray mass spectra are developed to obtain accurate structure information and subunit combinations.
Forteschi, Mauro; Zinellu, Angelo; Assaretti, Stefano; Mangoni, Arduino A; Pintus, Gianfranco; Carru, Ciriaco; Sotgia, Salvatore
2016-10-01
Plasma concentrations of choline, betaine, and dimethylglycine provide valuable information on the flow of methyl groups in key biological processes, particularly during folate deficiency states. We developed a new method to simultaneously measure these analytes in human plasma. Following sample deproteinization using acetonitrile, an aliquot was evaporated to dryness under vacuum to be then taken up by water. Finally, analytes were separated by capillary electrophoresis and detected by electrospray ionization triple-quadrupole mass spectrometry, in multiple reaction monitoring mode, using two stable isotope-labeled internal standards. Linearity of the calibration curves of each analyte was good (R(2) > 0.99). Average limits of detection (LODs) and limits of quantification (LOQs) for choline, betaine, and dimethylglycine were, respectively, 0.43, 0.62, and 0.31 μmol/L and 1.52, 2.11, and 0.97 μmol/L. Mean recovery of three replicates of two spiked concentrations levels was close to 100 % for all of the analytes. Repeatability and intermediate precision, expressed as %RSD of measurements, were <9 %. The method, applied to measure analytes in samples from 30 patients with chronic kidney disease and 30 age- and sex-matched healthy controls, was able to detect differences between groups and the sexes.
Koželj, Gordana; Perharič, Lucija; Stanovnik, Lovro; Prosen, Helena
2014-08-05
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of atropine and scopolamine in 100μL human plasma was developed and validated. Sample pretreatment consisted of protein precipitation with acetonitrile followed by a concentration step. Analytes and levobupivacaine (internal standard) were separated on a Zorbax XDB-CN column (75mm×4.6mm i.d., 3.5μm) with gradient elution (purified water, acetonitrile, formic acid). The triple quadrupole MS was operated in ESI positive mode. Matrix effect was estimated for deproteinised plasma samples. Selected reaction monitoring (SRM) was used for quantification in the range of 0.10-50.00ng/mL. Interday precision for both tropanes and intraday precision for atropine was <10%, intraday precision for scopolamine was <14% and <18% at lower limit of quantification (LLOQ). Mean interday and intraday accuracies for atropine were within ±7% and for scopolamine within ±11%. The method can be used for determination of therapeutic and toxic levels of both compounds and has been successfully applied to a study of pharmacodynamic and pharmacokinetic properties of tropanes, where plasma samples of volunteers were collected at fixed time intervals after ingestion of a buckwheat meal, spiked with five low doses of tropanes. Copyright © 2014 Elsevier B.V. All rights reserved.
Zheng, Jian; Tagami, Keiko; Bu, Wenting; Uchida, Shigeo; Watanabe, Yoshito; Kubota, Yoshihisa; Fuma, Shoichi; Ihara, Sadao
2014-05-20
Since the Fukushima Daiichi nuclear power plant (FDNPP) accident in 2011, intensive studies of the distribution of released fission products, in particular (134)Cs and (137)Cs, in the environment have been conducted. However, the release sources, that is, the damaged reactors or the spent fuel pools, have not been identified, which resulted in great variation in the estimated amounts of (137)Cs released. Here, we investigated heavily contaminated environmental samples (litter, lichen, and soil) collected from Fukushima forests for the long-lived (135)Cs (half-life of 2 × 10(6) years), which is usually difficult to measure using decay-counting techniques. Using a newly developed triple-quadrupole inductively coupled plasma tandem mass spectrometry method, we analyzed the (135)Cs/(137)Cs isotopic ratio of the FDNPP-released radiocesium in environmental samples. We demonstrated that radiocesium was mainly released from the Unit 2 reactor. Considering the fact that the widely used tracer for the released Fukushima accident-sourced radiocesium in the environment, the (134)Cs/(137)Cs activity ratio, will become unavailable in the near future because of the short half-life of (134)Cs (2.06 years), the (135)Cs/(137)Cs isotopic ratio can be considered as a new tracer for source identification and long-term estimation of the mobility of released radiocesium in the environment.
Gu, Dan; Raymundo, Melissa M; Kadlubar, Fred F; Turesky, Robert J
2011-02-01
The cooked meat carcinogens 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP), 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline (MeIQx), and their principal metabolites produced by cytochrome P450 and/or uridine diphosphate glucuronosyl transferases were simultaneously measured at the parts per trillion level in urine of omnivores, by ultraperformance liquid chromatography (UPLC) with a Michrom Advance CaptiveSpray source and a triple stage quadrupole mass spectrometer. Quantitation was performed in the selected reaction monitoring mode. The UPLC method is much more rapid and sensitive than our earlier capillary HPLC method: the duty cycle of the UPLC method is 19 min compared to 57 min for capillary HPLC. The performance of the UPLC assay was evaluated with urine samples from three subjects over 4 different days. The intraday and interday precisions of the estimates of PhIP, MeIQx, and their metabolites, reported as the coefficients of variation, were ≤10%. The limit of quantification (LOQ) values for PhIP and MeIQx were about 5 pg/mL, whereas the LOQ values of their metabolites ranged from 10 to 40 pg/mL. Furthermore, the identities of the analytes were corroborated by acquisition of full scan product ion spectra, employing between 0.5 and 5 pg of analyte for assay.
Liang, Xiao; Tian, Jinlong; Li, Lingzhi; Gao, Jun; Zhang, Qingyi; Gao, Pinyi; Song, Shaojiang
2014-03-01
A rapid and reliable microwave extraction and the triple quadrupole-linear ion trap mass spectrometry method was developed and validated for the determination of eight alkaloids in Portulaca oleracea L. The optimal microwave extraction (MWE) condition was performed at 60 °C for 12 min with ethanol-water (70:30, v/v) as the extracting solvent, and the solvent to solid ratio was 30:1. The alkaloids were first detected simultaneously by electrospray ionization tandem mass spectrometry under positive-negative conversion multiple reaction monitor ((+/-)MRM) technique. With investigating three different columns, samples were separated in only 8 min on a Waters ACQUITY UPLC HSS T3 (50 × 2.1 mm(2), 1.8 μm) column using acetonitrile and formic acid-water solution as a mobile phase with a flow rate at 0.2 mL/min. All calibration curves showed good linearity (r>0.999) within the test ranges. The method developed was validated with acceptable sensitivity, intra- and inter-day precision, reproducibility, and extraction recoveries. It was successfully applied to the determination of eight alkaloids in Portulaca oleracea L. from different sources and different harvest periods. The method also provide a reference for extraction and determination of alkaloids in other complex systems. © 2013 Elsevier B.V. All rights reserved.
Identification of Vitamin D3 Oxidation Products Using High-Resolution and Tandem Mass Spectrometry.
Mahmoodani, Fatemeh; Perera, Conrad O; Abernethy, Grant; Fedrizzi, Bruno; Greenwood, David; Chen, Hong
2018-03-19
In a successful fortification program, the stability of micronutrients added to the food is one of the most important factors. The added vitamin D3 is known to sometimes decline during storage of fortified milks, and oxidation through fatty acid lipoxidation could be suspected as the likely cause. Identification of vitamin D3 oxidation products (VDOPs) in natural foods is a challenge due to the low amount of their contents and their possible transformation to other compounds during analysis. The main objective of this study was to find a method to extract VDOPs in simulated whole milk powder and to identify these products using LTQ-ion trap, Q-Exactive Orbitrap and triple quadrupole mass spectrometry. The multistage mass spectrometry (MS n ) spectra can help to propose plausible schemes for unknown compounds and their fragmentations. With the growth of combinatorial libraries, mass spectrometry (MS) has become an important analytical technique because of its speed of analysis, sensitivity, and accuracy. This study was focused on identifying the fragmentation rules for some VDOPs by incorporating MS data with in silico calculated MS fragmentation pathways. Diels-Alder derivatization was used to enhance the sensitivity and selectivity for the VDOPs' identification. Finally, the confirmed PTAD-derivatized target compounds were separated and analyzed using ESI(+)-UHPLC-MS/MS in multiple reaction monitoring (MRM) mode. Graphical Abstract ᅟ.
Park, Ah Yeon; Park, So-Young; Lee, Jaehyun; Jung, Mihye; Kim, Jinwoong; Kang, Sam Sik; Youm, Jeong-Rok; Han, Sang Beom
2009-10-01
Rapid, simple and reliable HPLC/UV and LC-ESI-MS/MS methods for the simultaneous determination of five active coumarins of Angelicae dahuricae Radix, byakangelicol (1), oxypeucedanin (2), imperatorin (3), phellopterin (4) and isoimperatorin (5) were developed and validated. The separation condition for HPLC/UV was optimized using a Develosil RPAQUEOUS C(30) column using 70% acetonitrile in water as the mobile phase. This HPLC/UV method was successful for providing the baseline separation of the five coumarins with no interfering peaks detected in the 70% ethanol extract of Angelicae dahuricae Radix. The specific determination of the five coumarins was also accomplished by a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization source (LC-ESI-MS/MS). Multiple reaction monitoring (MRM) in the positive mode was used to enhance the selectivity of detection. The LC-ESI-MS/MS methods were successfully applied for the determination of the five major coumarins in Angelicae dahuricae Radix. These HPLC/UV and LC-ESI-MS/MS methods were validated in terms of recovery, linearity, accuracy and precision (intra- and inter-day validation). Taken together, the shorter analysis time involved makes these HPLC/UV and LC-ESI-MS/MS methods valuable for the commercial quality control of Angelicae dahuricae Radix extracts and its pharmaceutical preparations. Copyright (c) 2009 John Wiley & Sons, Ltd.
Identification of Vitamin D3 Oxidation Products Using High-Resolution and Tandem Mass Spectrometry
NASA Astrophysics Data System (ADS)
Mahmoodani, Fatemeh; Perera, Conrad O.; Abernethy, Grant; Fedrizzi, Bruno; Greenwood, David; Chen, Hong
2018-03-01
In a successful fortification program, the stability of micronutrients added to the food is one of the most important factors. The added vitamin D3 is known to sometimes decline during storage of fortified milks, and oxidation through fatty acid lipoxidation could be suspected as the likely cause. Identification of vitamin D3 oxidation products (VDOPs) in natural foods is a challenge due to the low amount of their contents and their possible transformation to other compounds during analysis. The main objective of this study was to find a method to extract VDOPs in simulated whole milk powder and to identify these products using LTQ-ion trap, Q-Exactive Orbitrap and triple quadrupole mass spectrometry. The multistage mass spectrometry (MSn) spectra can help to propose plausible schemes for unknown compounds and their fragmentations. With the growth of combinatorial libraries, mass spectrometry (MS) has become an important analytical technique because of its speed of analysis, sensitivity, and accuracy. This study was focused on identifying the fragmentation rules for some VDOPs by incorporating MS data with in silico calculated MS fragmentation pathways. Diels-Alder derivatization was used to enhance the sensitivity and selectivity for the VDOPs' identification. Finally, the confirmed PTAD-derivatized target compounds were separated and analyzed using ESI(+)-UHPLC-MS/MS in multiple reaction monitoring (MRM) mode. [Figure not available: see fulltext.
Zheng, Xiaochun; Mi, Xiaoxia; Li, Sicong; Chen, Gang
2013-06-01
Xylazine is a potent α2-adrenergic agonist used in veterinary medicine for sedation, analgesia, muscle relaxation, and so on. Its residue in animal-derived food may cause the food safety problem. Moreover, the metabolite 2,6-xylidine was reported to be a genotoxic and carcinogenic compound. Therefore, it is necessary to develop a high sensitive method for analyzing xylazine and metabolite residue in animal products. Here, we described a LC-MS/MS method for simultaneous determination of xylazine and 2,6-xylidine in 4 animal tissues: liver, meat, kidney, and fat. The samples were extracted by acetonitrile, and further clean up by hexane. The analysis was performed on a C18 reversed-phase column and API 5000 Triple Quadrupole mass spectrometry with positive electrospray ionization interface operating in the multiple-reaction monitoring mode. For all of the investigated sample matrix, the limit of detection (limit of quantitation) for xylazine and 2,6-xylidine were 0.06 (0.2) and 1.5 (5) μg/kg, respectively, the recoveries were between 63.5% and 90.8%. The precision was within the range of required criteria for method development. The presented method is sensitive and reproducible, and thus suitable for accurate quantification of xylazine and metabolite residue in animal-derived food products. © 2013 Institute of Food Technologists®
Petrarca, Mateus Henrique; Ccanccapa-Cartagena, Alexander; Masiá, Ana; Godoy, Helena Teixeira; Picó, Yolanda
2017-05-12
A new selective and sensitive liquid chromatography triple quadrupole mass spectrometry method was developed for simultaneous analysis of natural pyrethrins and synthetic pyrethroids residues in baby food. In this study, two sample preparation methods based on ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) and salting-out assisted liquid-liquid extraction (SALLE) were optimized, and then, compared regarding the performance criteria. Appropriate linearity in solvent and matrix-based calibrations, and suitable recoveries (75-120%) and precision (RSD values≤16%) were achieved for selected analytes by any of the sample preparation procedures. Both methods provided the analytical selectivity required for the monitoring of the insecticides in fruit-, cereal- and milk-based baby foods. SALLE, recognized by cost-effectiveness, and simple and fast execution, provided a lower enrichment factor, consequently, higher limits of quantification (LOQs) were obtained. Some of them too high to meet the strict legislation regarding baby food. Nonetheless, the combination of ultrasound and DLLME also resulted in a high sample throughput and environmental-friendly method, whose LOQs were lower than the default maximum residue limit (MRL) of 10μgkg -1 set by European Community for baby foods. In the commercial baby foods analyzed, cyhalothrin and etofenprox were detected in different samples, demonstrating the suitability of proposed method for baby food control. Copyright © 2017 Elsevier B.V. All rights reserved.
Piešťanský, Juraj; Maráková, Katarína; Kovaľ, Marián; Havránek, Emil; Mikuš, Peter
2015-12-01
A new multidimensional analytical approach for the ultra-trace determination of target chiral compounds in unpretreated complex real samples was developed in this work. The proposed analytical system provided high orthogonality due to on-line combination of three different methods (separation mechanisms), i.e. (1) isotachophoresis (ITP), (2) chiral capillary zone electrophoresis (chiral CZE), and (3) triple quadrupole mass spectrometry (QqQ MS). The ITP step, performed in a large bore capillary (800 μm), was utilized for the effective sample pretreatment (preconcentration and matrix clean-up) in a large injection volume (1-10 μL) enabling to obtain as low as ca. 80 pg/mL limits of detection for the target enantiomers in urine matrices. In the chiral CZE step, the different chiral selectors (neutral, ionizable, and permanently charged cyclodextrins) and buffer systems were tested in terms of enantioselectivity and influence on the MS detection response. The performance parameters of the optimized ITP - chiral CZE-QqQ MS method were evaluated according to the FDA guidance for bioanalytical method validation. Successful validation and application (enantioselective monitoring of renally eliminated pheniramine and its metabolite in human urine) highlighted great potential of this chiral approach in advanced enantioselective biomedical applications. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Poklis, Justin L.; Clay, Deborah J.; Poklis, Alphonse
2014-01-01
We present a high-performance liquid chromatography triple quadrupole mass spectrometry (HPLC–MS-MS) method for the identification and quantification of nine serotonin 5-HT2A receptor agonist hallucinogenic substances from a new class of N-methoxybenzyl derivatives of methoxyphenylethylamine (NBOMe) designer drugs in human urine: 25H-NBOMe, 2CC-NBOMe, 25I-NBF, 25D-NBOMe, 25B-NBOMe, 2CT-NBOMe, 25I-NBMD, 25G-NBOMe and 25I-NBOMe. This assay was developed for the Virginia Commonwealth University Clinical and Forensic Toxicology laboratory to screen emergency department specimens in response to an outbreak of N-benzyl-phenethylamine derivative abuse and overdose cases in Virginia. The NBOMe derivatives were rapidly extracted from the urine specimens by use of FASt™ solid-phase extraction columns. Assay performance was determined as recommended for validation by the Scientific Working Group for Forensic Toxicology (SWGTOX) for linearity, lower limit of quantification, lower limit of detection, accuracy/bias, precision, dilution integrity, carryover, selectivity, absolute recovery, ion suppression and stability. Linearity was verified to be from 1 to 100 ng/mL for each of the nine analytes. The bias determined for the NBOMe derivatives was 86–116% with a <14% coefficient of variation over the linear range of the assay. Four different NBOMe derivatives were detected using the presented method in patient urine specimens. PMID:24535338
Patrick, J S; Cooks, R G; Pachuta, S J
1994-11-01
Nucleic acid constituents can be bound to a metal surface in the form of self-assembled monolayers. Binding is achieved either through ionic interactions with a self-assembled 2-aminoethanethiol monolayer or by direct covalent binding of a dithiophosphate oligonucleotide to a metal surface through a sulfur-metal bond. Nucleotides, polynucleotides (both normal and a dithiophosphate analog) and double-stranded DNA have all been bound to surfaces. When the surfaces are interrogated using static secondary ion mass spectrometry (SIMS), the surface-bound nucleic acid constituents are observed in the form of the characteristic protonated nucleic acid base ions (BH2+). While a silver foil substrate was found to provide the highest absolute signal, vapor-deposited gold yields the best signal-to-noise ratio for ionically bound deoxyguanosine monophosphate. Under comparable conditions, a Cs+ projectile produces a 10-fold increase in the secondary ion signal relative to a Ga+ projectile. The experiment has been extended to a triple-quadrupole instrument where tandem mass spectrometric experiments on ionically immobilized dGMP showed the characteristic loss of ammonia from the released BH2+ ion. When a 'biomimetic' surface formed by ionically immobilizing double-stranded DNA is exposed to a solution containing ethidium bromide, ions corresponding to the non-covalent adduct are readily detectable using SIMS. This adduct and the nucleic acid constituents can be monitored at levels below 10 fmol.
Wang, Zhe; Zhou, Xinmiao; Liu, Xin; Dong, Ying; Zhang, Jinlan
2017-01-01
Stanozolol is one of the most commonly abused anabolic androgenic steroids (AAS) by athletes and usually detected by its parent drug and major metabolites. However, its metabolic pathway is complex, varied and individually different, it is important to characterize its overall metabolic profiles and discover new and long-term metabolites for the aims of expanding detection windows. High performance liquid chromatography coupled with triple quadrupole mass spectrometer (HPLC-MS/MS) was used to analyze the human urine after oral administration of stanozolol. Multiple reaction monitoring (MRM), one of the scan modes of triple quadrupole mass spectrometer showing extremely high sensitivity was well used to develop a strategy for metabolic profiles characterization and long-term metabolites detection based on typical precursor to product ion transitions of parent drug and its major metabolites. Utilizing the characteristic fragment ions of stanozolol and its major metabolites as the product ions, and speculating unknown precursor ions based on the possible phase I and phase II metabolic reactions in human body, the metabolite profiles of stanozolol could be comprehensively discovered, especially for those unknown and low concentration metabolites in human urine. Then these metabolites were further well structure identified by targeted high resolution MS/MS scan of quadrupole-time of flight mass spectrometry (Q-TOF). Applying this strategy, 27 phase I and 21 phase II metabolites of stanozolol were identified, in which 13 phase I and 14 phase II metabolites have not been reported previously. The 9 out of 48 metabolites could be detected over 15days post drug administration. This strategy could be employed effectively to characterize AAS metabolic profiles and discover unknown and long-term metabolites in sports drug testing. Copyright © 2016 Elsevier B.V. All rights reserved.
Yao, Zhoulin; Li, Xiaoge; Miao, Yelong; Lin, Mei; Xu, Mingfei; Wang, Qiang; Zhang, Hu
2015-11-01
A novel, sensitive, and efficient enantioselective method for the determination of triadimefon and its metabolite triadimenol in edible vegetable oil, was developed by gel permeation chromatography and ultraperformance convergence chromatography/tandem triple quadrupole mass spectrometry. After the vegetable oil samples were prepared using gel permeation chromatography, the eluent was collected, evaporated, and dried with nitrogen gas. The residue was redissolved by adding methanol up to a final volume of 1 mL. The analytes of six enantiomers were analyzed on Chiralpak IA-3 column (150 × 4.6 mm) using compressed liquid CO2-mixed 14 % co-solvents, comprising methanol/acetonitrile/isopropanol = 20/20/60 (v/v/v) in the mobile phase at 30 °C, and the total separation time was less than 4 min at a flow rate of 2 mL/min. Quantification was achieved using matrix-matched standard calibration curves. The overall mean recoveries for six enantiomers from vegetable oil were 90.1-97.3 %, with relative standard deviations of 0.8-5.4 % intra-day and 2.3-5.0 % inter-day at 0.5, 5, and 50 μg/kg levels. The limits of quantification were 0.5 μg/kg for all enantiomers based on five replicate extractions at the lowest fortified level in vegetable oil. Moreover, the absolute configuration of six enantiomers had been determined based on comparisons of the vibrational circular dichroism experimental spectra with the theoretical curve obtained by density functional theory calculations. Application of the proposed method to the 40 authentic vegetable oil samples from local markets suggests its potential use in enantioselective determination of triadimefon and triadimenol enantiomers. Graphical Abstract Chemical structures and UPC(2)-MS/MS separation chromatograms of triadimefon and triadimenol.
Miller, Eleanor I; Murray, Gordon J; Rollins, Douglas E; Tiffany, Stephen T; Wilkins, Diana G
2011-07-01
The aim of this exploratory study was to develop and validate a liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for the quantification of nicotine, eight nicotine metabolites, and two minor tobacco alkaloids in fortified analyte-free hair and subsequently apply this method to hair samples collected from active smokers. An additional aim of the study was to include an evaluation of different wash procedures for the effective removal of environmentally deposited nicotine from tobacco smoke. An apparatus was designed for the purpose of exposing analyte-free hair to environmental tobacco smoke in order to deposit nicotine onto the hair surface. A shampoo/water wash procedure was identified as the most effective means of removing nicotine. This wash procedure was utilized for a comparison of washed and unwashed heavy smoker hair samples. Analytes and corresponding deuterated internal standards were extracted using a cation-exchange solid-phase cartridge. LC-MS-MS was carried out using an Acquity™ UPLC(®) system (Waters) and a Quattro Premier XE™ triple quadrupole MS (Waters) operated in electrospray positive ionization mode, with multiple reaction monitoring data acquisition. The developed method was applied to hair samples collected from heavy smokers (n = 3) and low-level smokers (n = 3) collected through IRB-approved protocols. Nicotine, cotinine, and nornicotine were quantified in both the washed and unwashed hair samples collected from three heavy smokers, whereas 3-hydroxycotinine was quantified in only one unwashed sample and nicotine-1'-oxide in the washed and unwashed hair samples from two heavy smokers. In contrast, nicotine-1'-oxide was quantified in one of the three low-level smoker samples; nicotine was quantified in the other two low-level smoker samples. No other analytes were detected in the hair of the three low-level smokers.
Pantano, Flaminia; Brauneis, Stefano; Forneris, Alexandre; Pacifici, Roberta; Marinelli, Enrico; Kyriakou, Chrystalla; Pichini, Simona; Busardò, Francesco Paolo
2017-08-28
Oxycodone is a narcotic drug widely used to alleviate moderate and severe acute and chronic pain. Variability in analgesic efficacy could be explained by inter-subject variations in plasma concentrations of parent drug and its active metabolite, oxymorphone. To evaluate patient compliance and to set up therapeutic drug monitoring (TDM), an ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) assay was developed and validated for the parent drug and its major metabolites noroxycodone and oxymorphone. Extraction of analytes from plasma and urine samples was obtained by simple liquid-liquid extraction. The chromatographic separation was achieved with a reversed phase column using a linear gradient elution with two solvents: acetic acid 1% in water and methanol. The separated analytes were detected with a triple quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode via positive electrospray ionization (ESI). Separation of analytes was obtained in less than 5 min. Linear calibration curves for all the analytes under investigation in urine and plasma samples showed determination coefficients (r2) equal or higher than 0.990. Mean absolute analytical recoveries were always above 86%. Intra- and inter-assay precision (measured as coefficient of variation, CV%) and accuracy (measured as % error) values were always better than 13%. Limit of detection at 0.06 and 0.15 ng/mL and limit of quantification at 0.2 and 0.5 ng/mL for plasma and urine samples, respectively, were adequate for the purpose of the present study. Rapid extraction, identification and quantification of oxycodone and its metabolites both in urine and plasma by UHPLC-MS/MS assay was tested for its feasibility in clinical samples and provided excellent results for rapid and effective drug testing in patients under oxycodone treatment.
Wang, Chao; Riedl, Ken M.; Schwartz, Steven J.
2013-01-01
Folate deficiency is a prevalent phenomenon worldwide especially in underprivileged countries. Polyglutamyl 5-methyltetrahydrofolate (5MTHF) species are the naturally occurring principle folate in store-bought vegetables. Here we report a simple and complete extraction method for the determination of native polyglutamyl 5-methyltetrahydrofolate in vegetables using high performance liquid chromatography with tandem mass spectrometric detection (HPLC–MS/MS). Coarsely chopped samples (18 different vegetables) were steamed to inactivate glutamylase enzymes and liberate folate from binding proteins and extracted in a reducing buffer with 13C5 5MTHF stable isotope added as internal standard. The polyglutamyl 5-methyltetrahydrofolate species were separated in 9 min on a C18 column using a reversed phase system. HPLC eluate was interfaced with a triple quadrupole mass spectrometer operated in electrospray positive mode. The respective pseudomolecular cation of each polyglutamyl 5-methyltetrahydrofolate species was selected for fragmentation to a common daughter ion for detection. We quantitated polyglutamyl 5-methyltetrahydrofolate in store-bought vegetables from families Brassicaceae, Asteraceae and Amaranthaceae (including mustard greens, romaine lettuce and Swiss chard) of which most have not been quantitated previously. Most vegetables from Asteraceae and those from Amaranthaceae contained similar amounts of monoglutamyl 5MTHF and polyglutamyl 5MTHF while Brassicaceae were dominated by polyglutamyls and endive species (Asteraceae) contained mainly monoglutamyl 5MTHF. The precision of the method for the various polyglutamyl 5-methyltetrahydrofolate forms was 1–9% RSD, recovery 84–91%, limit of detection 64–658 fmol and limit of quantitation 193–1994 fmol. Herein we describe a rapid, sensitive and selective HPLC–MS/MS technique to quantitate polyglutamyl 5-methyltetrahydrofolate species. This method may be suitable for analyzing the polyglutamyl 5-methyltetrahydrofolate profile of inherent folates in a wide range of leafy green vegetables. PMID:20888309
Scheidweiler, Karl B.; Himes, Sarah K.; Chen, Xiaohong; Liu, Hua-Fen
2013-01-01
Currently, Δ9-tetrahydrocannabinol (THC) is the analyte quantified for oral fluid cannabinoid monitoring. The potential for false-positive oral fluid cannabinoid results from passive exposure to THC-laden cannabis smoke raises concerns for this promising new monitoring technology. Oral fluid 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCCOOH) is proposed as a marker of cannabis intake since it is not present in cannabis smoke and was not measureable in oral fluid collected from subjects passively exposed to cannabis. THCCOOH concentrations are in the picogram per milliliter range in oral fluid and pose considerable analytical challenges. A liquid chromatography–tandem mass spectrometry (LCMSMS) method was developed and validated for quantifying THCCOOH in 1 mL Quantisal-collected oral fluid. After solid phase extraction, chromatography was performed on a Kinetex C18 column with a gradient of 0.01 % acetic acid in water and 0.01 % acetic acid in methanol with a 0.5-mL/min flow rate. THCCOOH was monitored in negative mode electrospray ionization and multiple reaction monitoring mass spectrometry. The THCCOOH linear range was 12–1,020 pg/mL (R2>0.995). Mean extraction efficiencies and matrix effects evaluated at low and high quality control (QC) concentrations were 40.8–65.1 and −2.4–11.5 %, respectively (n=10). Analytical recoveries (bias) and total imprecision at low, mid, and high QCs were 85.0–113.3 and 6.6–8.4 % coefficient of variation, respectively (n=20). This is the first oral fluid THCCOOH LCMSMS triple quadrupole method not requiring derivatization to achieve a <15 pg/mL limit of quantification. The assay is applicable for the workplace, driving under the influence of drugs, drug treatment, and pain management testing. PMID:23681203
Yang, Bin; Xu, Yanyan; Wu, Yuanyuan; Wu, Huanyu; Wang, Yuan; Yuan, Lei; Xie, Jiabin; Li, Yubo; Zhang, Yanjun
2016-10-15
A rapid, sensitive and selective ultra-high performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for simultaneous determination of ten Aconitum alkaloids in rat tissues. The tissue samples were prepared by a simple procedure protein precipitation with acetonitrile containing 0.1% acetic acid and separated on an Agilent XDB C18 column (4.6 mm×50mm, 1.8μm) using gradient elution with a mobile phase consisting of water and acetonitrile (both containing 0.1% formic acid) at a flow rate of 0.3mL/min. The quantitive determination was performed on an electrospray ionization (ESI) triple quadrupole tandem mass spectrometer using selective reaction monitoring (SRM) under positive ionization mode. The established method was fully validated according to the USA Food and Drug Administration (FDA) bioanalytical method validation guidance and the results demonstrated that the method was sensitive and selective with the lowest limits of quantification (LLOQ) at 0.025ng/mL in rat tissue homogenates. Meanwhile, the linearity, precision, accuracy, extraction recovery, matrix effect and stability were all within the required limits of biological sample analysis. After method validation, the validated method was successfully applied to the tissue distribution study on the compatibility of Heishunpian (HSP, the processed product of Aconitum carmichaelii Debx) and Fritillariae thunbergii Bulbus (Zhebeimu, ZBM). The results indicated that the distribution feature of monoester diterpenoid aconitines (MDAs), diester diterpenoid aconitines (DDAs) and non-ester alkaloids (NEAs) were inconsistency, and the compatibility of HSP and ZBM resulted in the distribution amount of DDAs increased in tissues. What's more, the results could provide the reliable basis for systematic research on the substance foundation of the compatibility of the herbal pair. Copyright © 2016 Elsevier B.V. All rights reserved.
Dobrinas, Maria; Choong, Eva; Noetzli, Muriel; Cornuz, Jacques; Ansermot, Nicolas; Eap, Chin B
2011-11-15
A sensitive and specific ultra performance liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of nicotine, its metabolites cotinine and trans-3'-hydroxycotinine and varenicline in human plasma was developed and validated. Sample preparation was realized by solid phase extraction of the target compounds and of the internal standards (nicotine-d4, cotinine-d3, trans-3'-hydroxycotinine-d3 and CP-533,633, a structural analog of varenicline) from 0.5 mL of plasma, using a mixed-mode cation exchange support. Chromatographic separations were performed on a hydrophilic interaction liquid chromatography column (HILIC BEH 2.1×100 mm, 1.7 μm). A gradient program was used, with a 10 mM ammonium formate buffer pH 3/acetonitrile mobile phase at a flow of 0.4 mL/min. The compounds were detected on a triple quadrupole mass spectrometer, operated with an electrospray interface in positive ionization mode and quantification was performed using multiple reaction monitoring. Matrix effects were quantitatively evaluated with success, with coefficients of variation inferior to 8%. The procedure was fully validated according to Food and Drug Administration guidelines and to Société Française des Sciences et Techniques Pharmaceutiques. The concentration range was 2-500 ng/mL for nicotine, 1-1000 ng/mL for cotinine, 2-1000 ng/mL for trans-3'-hydroxycotinine and 1-500 ng/mL for varenicline, according to levels usually measured in plasma. Trueness (86.2-113.6%), repeatability (1.9-12.3%) and intermediate precision (4.4-15.9%) were found to be satisfactory, as well as stability in plasma. The procedure was successfully used to quantify nicotine, its metabolites and varenicline in more than 400 plasma samples from participants in a clinical study on smoking cessation. Copyright © 2011 Elsevier B.V. All rights reserved.
Piešťanský, Juraj; Maráková, Katarína; Kovaľ, Marián; Mikuš, Peter
2014-09-05
The advanced two dimensional isotachophoresis (ITP)-capillary zone electrophoresis (CZE) hyphenated with tandem mass spectrometry (MS/MS, here triple quadrupole, QqQ) was developed in this work to demonstrate analytical potentialities of this approach in the analysis of drugs in multicomponent ionic matrices. Pheniramine (PHM), phenylephrine (PHE), paracetamol (PCM) and their potential metabolic products were taken for the analysis by the ITP-CZE-ESI-QqQ technique working in hydrodynamically closed CE separation system and then a comparison with the conventional (hydrodynamically open) CZE-ESI-QqQ technique was made. The ITP-CZE-ESI-QqQ method was favorable in terms of obtainable selectivity (due to highly effective heart-cut analysis), concentration limits of detection (LOD at pgmL(-1) levels due to enhanced sample load capacity and ITP preconcentration), sample handling (on-line sample pretreatment, i.e. clean-up, preconcentration, preseparation), and, by that, possibilities for future automation and miniaturization. On the other hand, this experimental arrangement, in contrast to the CZE-ESI-QqQ arrangement supported by an electroosmotic flow, is principally limited to the analysis of uniformly (i.e. positively or negatively) charged analytes in one run without any possibilities to analyze neutral compounds (here, PCM and neutral or acidic metabolites of the drugs had to be excluded from the analysis). Hence, these general characteristics should be considered when choosing a proper analytical CE-MS approach for a given biomedical application. Here, the analytical potential of the ITP-CZE-ESI-QqQ method was demonstrated showing the real time profiles of excreted targeted drugs and metabolite (PHM, PHE, M-PHM) in human urine after the administration of one dose of Theraflu(®) to the volunteers. Copyright © 2014 Elsevier B.V. All rights reserved.
Shaw, Jiajiu; Wiegand, Richard; Wu, Jianmei; Bao, Xun; Valeriote, Frederick; Li, Jing
2015-06-01
UTL-5g is a novel small-molecule TNF-α inhibitor under investigation as both a chemoprotective and radioprotective agent. Animal studies showed that pretreatment of UTL-5g protected kidney, liver, and platelets from cisplatin-induced toxicity. In addition, UTL-5g reduced liver and lung injuries induced by radiation in vivo. Although a number of preclinical studies have been conducted, a validated bioanalytical method for UTL-5g in human plasma has not been published. In this work, a sensitive and reproducible reverse-phase liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) assay was developed and validated for the determination of UTL-5g and its metabolites, 5-methylisoxazole-3-carboxylic acid (ISOX) and 2,4-dichloroaniline (DCA), in human plasma. The method involves a simple methanol precipitation step followed by injection of the supernatant onto a Waters 2695 HPLC system coupled with a Waters Quattro Micro™ triple quadrupole mass spectrometer. Chromatographic separation was accomplished using a Waters Nova-Pak C18 column maintained at 30°C, running at gradient mode with mobile phase consisting of 0.1% formic acid in water and 0.1% formic acid in methanol at a flow rate of 0.2mL/min. The analytes were monitored under positive electrospray ionization (ESI). Quantitation of these compounds in plasma was linear from 0.05 to 10μM. The lower limit of quantitation (LLOQ) was 0.05, 0.1, and 0.2μM for UTL-5g, ISOX and DCA, respectively. The accuracy and intra-and inter-day precisions were within the generally accepted criteria for bioanalytical method (<15%). This method provides a practical tool to measure and characterize the plasma concentration-time profiles for UTL-5g and its metabolites, ISOX and DCA. Copyright © 2015 Elsevier B.V. All rights reserved.
Milman, Boris L
2005-01-01
A library consisting of 3766 MS(n) spectra of 1743 compounds, including 3126 MS2 spectra acquired mainly using ion trap (IT) and triple-quadrupole (QqQ) instruments, was composed of numerous collections/sources. Ionization techniques were mainly electrospray ionization and also atmospheric pressure chemical ionization and chemical ionization. The library was tested for the performance in identification of unknowns, and in this context this work is believed to be the largest of all known tests of product-ion mass spectral libraries. The MS2 spectra of the same compounds from different collections were in turn divided into spectra of 'unknown' and reference compounds. For each particular compound, library searches were performed resulting in selection by taking into account the best matches for each spectral collection/source. Within each collection/source, replicate MS2 spectra differed in the collision energy used. Overall, there were up to 950 search results giving the best match factors and their ranks in corresponding hit lists. In general, the correct answers were obtained as the 1st rank in up to 60% of the search results when retrieved with (on average) 2.2 'unknown' and 6.2 reference replicates per compound. With two or more replicates of both 'unknown' and reference spectra (the average numbers of replicates were 4.0 and 7.8, respectively), the fraction of correct answers in the 1st rank increased to 77%. This value is close to the performance of established electron ionization mass spectra libraries (up to 79%) found by other workers. The hypothesis that MS2 spectra better match reference spectra acquired using the same type of tandem mass spectrometer (IT or QqQ) was neither strongly proved nor rejected here. The present work shows that MS2 spectral libraries containing sufficiently numerous different entries for each compound are sufficiently efficient for identification of unknowns and suitable for use with different tandem mass spectrometers. 2005 John Wiley & Sons, Ltd.
Millán Martín, Silvia; Delporte, Cédric; Farrell, Amy; Navas Iglesias, Natalia; McLoughlin, Niaobh; Bones, Jonathan
2015-03-07
A twoplex method using (12)C6 and (13)C6 stable isotope analogues (Δmass = 6 Da) of 2-aminobenzoic acid (2-AA) is described for quantitative analysis of N-glycans present on monoclonal antibodies and other glycoproteins using ultra performance liquid chromatography with sequential fluorescence and accurate mass tandem quadrupole time of flight (QToF) mass spectrometric detection.
Prostate Specific or Enriched Genes as Composite Biomarkers for Prostate Cancer
2008-02-01
isotope dilution by comparing to the 13C- or 15N-labeled reference peptides. The MRM method is best practiced utilizing a triple quadrupole mass...specific, androgen- regulated gene. Here, we evaluate its utility as a prostate cancer tissue marker for diagnosis and prognostic evaluation. Experimental...prevalence of adverse prognostic factors such as capsular penetration, seminal vesicle invasion, and positive surgical margins is rather high compared with
System and process for pulsed multiple reaction monitoring
Belov, Mikhail E
2013-05-17
A new pulsed multiple reaction monitoring process and system are disclosed that uses a pulsed ion injection mode for use in conjunction with triple-quadrupole instruments. The pulsed injection mode approach reduces background ion noise at the detector, increases amplitude of the ion signal, and includes a unity duty cycle that provides a significant sensitivity increase for reliable quantitation of proteins/peptides present at attomole levels in highly complex biological mixtures.
Abad-García, Beatriz; Berrueta, Luis A; Garmón-Lobato, Sergio; Gallo, Blanca; Vicente, Francisca
2009-07-10
In the present study, a methodology based on liquid chromatography with diode array detection (HPLC/DAD) coupled to an electrospray ionization (ESI) interface and a triple quadrupole mass spectrometer for the simultaneous identification of phenolic compounds in fruit juices has been developed. 72 available phenolic compound standards from diverse families present in fruits have been studied in order to analyze their fragmentation pattern. As a result, a general strategy for the characterization of unknown phenolic compounds in fruit juices was designed: (i) taking into account its UV-visible spectrum and elution order, assign the unknown polyphenol to a polyphenol class, (ii) identify the quasi-molecular ion using positive and negative MS spectra, being supported by adducts generated with solvent or sodium and molecular complexes, (iii) determinate the pattern of glycosylation in positive mode using ESI(+)-CID MS/MS product ion scan experiments, selecting the quasi-molecular ion as precursor ion, and finally, (iv) study the identity of the aglycone through ESI(+)-CID MS/MS product ion spectra from the protonated aglycone, [Y(0)](+). This strategy was successfully employed for the characterization of known and unknown phenolic compounds in juices from 17 different fruits.
Geometry-dependent atomic multipole models for the water molecule.
Loboda, O; Millot, C
2017-10-28
Models of atomic electric multipoles for the water molecule have been optimized in order to reproduce the electric potential around the molecule computed by ab initio calculations at the coupled cluster level of theory with up to noniterative triple excitations in an augmented triple-zeta quality basis set. Different models of increasing complexity, from atomic charges up to models containing atomic charges, dipoles, and quadrupoles, have been obtained. The geometry dependence of these atomic multipole models has been investigated by changing bond lengths and HOH angle to generate 125 molecular structures (reduced to 75 symmetry-unique ones). For several models, the atomic multipole components have been fitted as a function of the geometry by a Taylor series of fourth order in monomer coordinate displacements.
Geometry-dependent atomic multipole models for the water molecule
NASA Astrophysics Data System (ADS)
Loboda, O.; Millot, C.
2017-10-01
Models of atomic electric multipoles for the water molecule have been optimized in order to reproduce the electric potential around the molecule computed by ab initio calculations at the coupled cluster level of theory with up to noniterative triple excitations in an augmented triple-zeta quality basis set. Different models of increasing complexity, from atomic charges up to models containing atomic charges, dipoles, and quadrupoles, have been obtained. The geometry dependence of these atomic multipole models has been investigated by changing bond lengths and HOH angle to generate 125 molecular structures (reduced to 75 symmetry-unique ones). For several models, the atomic multipole components have been fitted as a function of the geometry by a Taylor series of fourth order in monomer coordinate displacements.
Guo, Fei; Li, Ning; Fecher, Frank W.; Gasparini, Nicola; Quiroz, Cesar Omar Ramirez; Bronnbauer, Carina; Hou, Yi; Radmilović, Vuk V.; Radmilović, Velimir R.; Spiecker, Erdmann; Forberich, Karen; Brabec, Christoph J.
2015-01-01
The multi-junction concept is the most relevant approach to overcome the Shockley–Queisser limit for single-junction photovoltaic cells. The record efficiencies of several types of solar technologies are held by series-connected tandem configurations. However, the stringent current-matching criterion presents primarily a material challenge and permanently requires developing and processing novel semiconductors with desired bandgaps and thicknesses. Here we report a generic concept to alleviate this limitation. By integrating series- and parallel-interconnections into a triple-junction configuration, we find significantly relaxed material selection and current-matching constraints. To illustrate the versatile applicability of the proposed triple-junction concept, organic and organic-inorganic hybrid triple-junction solar cells are constructed by printing methods. High fill factors up to 68% without resistive losses are achieved for both organic and hybrid triple-junction devices. Series/parallel triple-junction cells with organic, as well as perovskite-based subcells may become a key technology to further advance the efficiency roadmap of the existing photovoltaic technologies. PMID:26177808
Guo, Fei; Li, Ning; Fecher, Frank W; Gasparini, Nicola; Ramirez Quiroz, Cesar Omar; Bronnbauer, Carina; Hou, Yi; Radmilović, Vuk V; Radmilović, Velimir R; Spiecker, Erdmann; Forberich, Karen; Brabec, Christoph J
2015-07-16
The multi-junction concept is the most relevant approach to overcome the Shockley-Queisser limit for single-junction photovoltaic cells. The record efficiencies of several types of solar technologies are held by series-connected tandem configurations. However, the stringent current-matching criterion presents primarily a material challenge and permanently requires developing and processing novel semiconductors with desired bandgaps and thicknesses. Here we report a generic concept to alleviate this limitation. By integrating series- and parallel-interconnections into a triple-junction configuration, we find significantly relaxed material selection and current-matching constraints. To illustrate the versatile applicability of the proposed triple-junction concept, organic and organic-inorganic hybrid triple-junction solar cells are constructed by printing methods. High fill factors up to 68% without resistive losses are achieved for both organic and hybrid triple-junction devices. Series/parallel triple-junction cells with organic, as well as perovskite-based subcells may become a key technology to further advance the efficiency roadmap of the existing photovoltaic technologies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schnabel, Manuel; Tamboli, Adele C; Warren, Emily L
Despite steady advancements in the efficiency of crystalline Silicon (c-Si) photovoltaics (PV) within the last decades, the theoretical efficiency limit of 29.4 percent depicts an insurmountable barrier for silicon-based single-junction solar cells. Combining the Si cell with a second absorber material on top in a dual junction tandem or triple junction solar cell is an attractive option to surpass this limit significantly. We demonstrate a mechanically stacked GaInP/Si dual-junction cell with an in-house measured efficiency of 31.5 percent and a GaInP/GaAs/Si triple-junction cell with a certified efficiency of 35.4 percent.
Hoff, Rodrigo Barcellos; Pizzolato, Tânia Mara; Peralba, Maria do Carmo Ruaro; Díaz-Cruz, M Silvia; Barceló, Damià
2015-03-01
Sulfonamides are widely used in human and veterinary medicine. The presence of sulfonamides residues in food is an issue of great concern. Throughout the present work, a method for the targeted analysis of 16 sulfonamides and metabolites residue in liver of several species has been developed and validated. Extraction and clean-up has been statistically optimized using central composite design experiments. Two extraction methods have been developed, validated and compared: i) pressurized liquid extraction, in which samples were defatted with hexane and subsequently extracted with acetonitrile and ii) ultrasound-assisted extraction with acetonitrile and further liquid-liquid extraction with hexane. Extracts have been analyzed by liquid chromatography-quadrupole linear ion trap-tandem mass spectrometry. Validation procedure has been based on the Commission Decision 2002/657/EC and included the assessment of parameters such as decision limit (CCα), detection capability (CCβ), sensitivity, selectivity, accuracy and precision. Method׳s performance has been satisfactory, with CCα values within the range of 111.2-161.4 µg kg(-1), limits of detection of 10 µg kg(-1) and accuracy values around 100% for all compounds. Copyright © 2014 Elsevier B.V. All rights reserved.
Wang, Yang; Ma, Li; Sun, Yi; Yang, Liman; Yue, Hao; Liu, Shuying
2014-07-01
The hot syndrome refers to any feverish conditions during a pathological development, a sub-health phenomenon, and is a potential risk for human health. The metabonomics study on the hot syndrome may provide insight into understanding of its pathology and play a role in the prevention and treatment of its related diseases. In this paper, the rats were dosed with the hot syndrome prescription, ginseng and water. The corresponding urine samples were identified by rapid resolution liquid chromatography combined with quadrupole time-of-flight tandem mass spectrometry. More than 1,000 metabolic compounds from different urine samples could be further differentiated by principal component analysis. As a result, the rat body temperature and weight were recognized as the hot syndrome related factors. Some specific metabolites have been discovered as a pattern of the potential biomarkers for the hot syndrome. The results showed that ginseng cannot cause the hot syndrome in a reasonable dose, but the hot syndrome prescription can. It is suggested that ginseng cannot be used only as a tradition Chinese medicine but also as a nutrient. The work showed metabonomics method is a valuable tool in studying mechanism of the hot syndrome.
Zhao, Yong-Gang; Zhang, Yun; Wang, Feng-Lian; Zhou, Jian; Zhao, Qi-Ming; Zeng, Xiu-Qiong; Hu, Mei-Qin; Jin, Mi-Cong; Zhu, Yan
2018-08-01
The novel quaternary ammonium modified magnetic carboxyl-carbon nanotubes (QA-Mag-CCNTs) have been synthesised and characterized. QA-Mag-CCNTs were applied in magnetic dispersive solid phase extraction (Mag-dSPE) for preconcentration of perchlorate from tea leaves prior to liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS) analysis. The Mag-dSPE procedure for preconcentration of perchlorate succeed in overcoming the flaw (containing target analyte randomly) of commercially available SPE cartridge. Under optimal conditions, the results showed higher extraction efficiency of QA-Mag-CCNTs, with recoveries between 85.2% and 107%. And the satisfactory precision with inter-day and intra-day RSD values were lower than 8.0%. Furthermore, QA-Mag-CCNTs were evaluated for reuse up to 20 times. The limit of quantification (LOQ) for perchlorate was 8.21 ng kg -1 . The developed method was successfully applied in tea leaves for food-safety risk monitoring in Zhejiang province, China. The results showed the concentrations of perchlorate in 229 out of 240 collected samples were in the range of 0.082-988 μg kg -1 . It was confirmed that QA-Mag-CCNTs were highly effective materials used for preconcentration of perchlorate. Copyright © 2018 Elsevier B.V. All rights reserved.
Liu, Dongyang; Jiang, Ji; Zhang, Li; Tan, Fenlai; Wang, Yingxiang; Hu, Pei
2011-08-15
Icotinib is a novel anti-cancer drug that has shown promising clinical efficacy and safety in patients with non-small-cell lung cancer (NSCLC). At this time, the metabolic fate of icotinib in humans is unknown. In the present study, a liquid chromatography/quadrupole time-of-flight tandem mass spectrometry (LC/Q-TOF MS) method was established to characterize metabolites of icotinib in human plasma, urine and feces. In addition, nuclear magnetic resonance (NMR) detection was utilized to determine the connection between side-chain and quinazoline groups for some complex metabolites. In total, 29 human metabolites (21 isomer metabolites) were characterized, of which 23 metabolites are novel compared to the metabolites in rats. This metabolic study revealed that icotinib was extensively metabolized at the 12-crown-4 ether moiety (ring-opening and further oxidation), carbon 15 (hydroxylation) and an acetylene moiety (oxidation) to yield 19 oxidized metabolites and to further form 10 conjugates with sulfate acid or glucuronic acid. To our knowledge, this is the first report of the human metabolic profile of icotinib. Study results indicated that significant attention should be paid to the metabolic profiles of NSCLC patients during the development of icotinib. Copyright © 2011 John Wiley & Sons, Ltd.
Chen, Xiao-Hong; Zhao, Yong-Gang; Shen, Hao-Yu; Jin, Mi-Cong
2012-11-09
A novel and effective dispersive solid-phase extraction (dSPE) procedure with rapid magnetic separation using ethylenediamine-functionalized magnetic polymer as an adsorbent was developed. The new procedure had excellent clean-up ability for the selective removal of the matrix in red wine. An accurate, simple, and rapid analytical method using ultra-fast liquid chromatography-tandem quadrupole mass spectrometry (UFLC-MS/MS) for the simultaneous determination of nine food additives (i.e., acesulfame, saccharin, sodium cyclamate, aspartame, benzoic acid, sorbic acid, stevioside, dehydroacetic acid, and neotame) in red wine was also used and validated. Recoveries ranging from 78.5% to 99.2% with relative standard deviations ranging from 0.46% to 6.3% were obtained using the new method. All target compounds showed good linearities in the tested range with correlation coefficients (r) higher than 0.9993. The limits of quantification for the nine food additives were between 0.10 μg/L and 50.0 μg/L. The proposed dSPE-UFLC-MS/MS method was successfully applied in the food-safety risk monitoring of real red wine in Zhejiang Province, China. Crown Copyright © 2012. Published by Elsevier B.V. All rights reserved.
Chemical Ionization Mass Spectrometry.
1980-01-30
8217 ’ b o t5D&(( Irff irent from Controlling Office) IS. SECURITY CLASS. (of this report) 1< ; ~ / 1-j~. Unclassified 1S. DECLASSI FI CATION/DOWNGRADING...level in industrial sludge without any prior chromatogaphic or wet chemical separation of this comolex matrix. D. F. Hunt, J. Shabanowitz, and A. B ...Analytical Cheristry, April 1979 12)D. F. Hunt , J. Shabanowitz, and A. B . Giordani, Collision Activated Decompositions or Megative Ions in a Triple Quadrupole
Quadrupole collectivity in 42Ca from low-energy Coulomb excitation with AGATA
NASA Astrophysics Data System (ADS)
Hadyńska-Klęk, K.; Napiorkowski, P. J.; Zielińska, M.; Srebrny, J.; Maj, A.; Azaiez, F.; Valiente Dobón, J. J.; Kicińska-Habior, M.; Nowacki, F.; Naïdja, H.; Bounthong, B.; Rodríguez, T. R.; de Angelis, G.; Abraham, T.; Anil Kumar, G.; Bazzacco, D.; Bellato, M.; Bortolato, D.; Bednarczyk, P.; Benzoni, G.; Berti, L.; Birkenbach, B.; Bruyneel, B.; Brambilla, S.; Camera, F.; Chavas, J.; Cederwall, B.; Charles, L.; Ciemała, M.; Cocconi, P.; Coleman-Smith, P.; Colombo, A.; Corsi, A.; Crespi, F. C. L.; Cullen, D. M.; Czermak, A.; Désesquelles, P.; Doherty, D. T.; Dulny, B.; Eberth, J.; Farnea, E.; Fornal, B.; Franchoo, S.; Gadea, A.; Giaz, A.; Gottardo, A.; Grave, X.; Grębosz, J.; Görgen, A.; Gulmini, M.; Habermann, T.; Hess, H.; Isocrate, R.; Iwanicki, J.; Jaworski, G.; Judson, D. S.; Jungclaus, A.; Karkour, N.; Kmiecik, M.; Karpiński, D.; Kisieliński, M.; Kondratyev, N.; Korichi, A.; Komorowska, M.; Kowalczyk, M.; Korten, W.; Krzysiek, M.; Lehaut, G.; Leoni, S.; Ljungvall, J.; Lopez-Martens, A.; Lunardi, S.; Maron, G.; Mazurek, K.; Menegazzo, R.; Mengoni, D.; Merchán, E.; Męczyński, W.; Michelagnoli, C.; Million, B.; Myalski, S.; Napoli, D. R.; Niikura, M.; Obertelli, A.; Özmen, S. F.; Palacz, M.; Próchniak, L.; Pullia, A.; Quintana, B.; Rampazzo, G.; Recchia, F.; Redon, N.; Reiter, P.; Rosso, D.; Rusek, K.; Sahin, E.; Salsac, M.-D.; Söderström, P.-A.; Stefan, I.; Stézowski, O.; Styczeń, J.; Theisen, Ch.; Toniolo, N.; Ur, C. A.; Wadsworth, R.; Wasilewska, B.; Wiens, A.; Wood, J. L.; Wrzosek-Lipska, K.; Ziębliński, M.
2018-02-01
A Coulomb-excitation experiment to study electromagnetic properties of 42Ca was performed using a 170-MeV calcium beam from the TANDEM XPU facility at INFN Laboratori Nazionali di Legnaro. γ rays from excited states in 42Ca were measured with the AGATA spectrometer. The magnitudes and relative signs of ten E 2 matrix elements coupling six low-lying states in 42Ca, including the diagonal E 2 matrix elements of 21+ and 22+ states, were determined using the least-squares code gosia. The obtained set of reduced E 2 matrix elements was analyzed using the quadrupole sum rule method and yielded overall quadrupole deformation for 01,2 + and 21,2 + states, as well as triaxiality for 01,2 + states, establishing the coexistence of a weakly deformed ground-state band and highly deformed slightly triaxial sideband in 42Ca. The experimental results were compared with the state-of-the-art large-scale shell-model and beyond-mean-field calculations, which reproduce well the general picture of shape coexistence in 42Ca.
Krokhin, Oleg; Ens, Werner; Standing, Kenneth G; Wilkins, John; Perreault, Hélène
2004-01-01
The identification of glycosylation sites in proteins is often possible through a combination of proteolytic digestion, separation, mass spectrometry (MS) and tandem MS (MS/MS). Liquid chromatography (LC) in combination with MS/MS has been a reliable method for detecting glycopeptides in digestion mixtures, and for assigning glycosylation sites and glycopeptide sequences. Direct interfacing of LC with MS relies on electrospray ionization, which produces ions with two, three or four charges for most proteolytic peptides and glycopeptides. MS/MS spectra of such glycopeptide ions often lead to ambiguous interpretation if deconvolution to the singly charged level is not used. In contrast, the matrix-assisted laser desorption/ionization (MALDI) technique usually produces singly charged peptide and glycopeptide ions. These ions require an extended m/z range, as provided by the quadrupole-quadrupole time-of-flight (QqTOF) instrument used in these experiments, but the main advantages of studying singly charged ions are the simplicity and consistency of the MS/MS spectra. A first aim of the present study is to develop methods to recognize and use glycopeptide [M+H]+ ions as precursors for MS/MS, and thus for glycopeptide/glycoprotein identification as part of wider proteomics studies. Secondly, this article aims at demonstrating the usefulness of MALDI-MS/MS spectra of N-glycopeptides. Mixtures of diverse types of proteins, obtained commercially, were prepared and subjected to reduction, alkylation and tryptic digestion. Micro-column reversed-phase separation allowed deposition of several fractions on MALDI plates, followed by MS and MS/MS analysis of all peptides. Glycopeptide fractions were identified after MS by their specific m/z spacing patterns (162, 203, 291 u) between glycoforms, and then analyzed by MS/MS. In most cases, MS/MS spectra of [M+H]+ ions of glycopeptides featured peaks useful for determining sugar composition, peptide sequence, and thus probable glycosylation site. Peptide-related product ions could be used in database search procedures and allowed the identification of the glycoproteins. Copyright 2004 John Wiley & Sons, Ltd.
Mogollón, Noroska Gabriela Salazar; Prata, Paloma Santana; Dos Reis, Jadson Zeni; Neto, Eugênio Vaz Dos Santos; Augusto, Fabio
2016-09-01
Oil samples from Recôncavo basin (NE Brazil), previously analyzed by traditional techniques such as gas chromatography coupled to tandem mass spectrometry, were evaluated using comprehensive two-dimensional gas chromatography coupled to quadrupole mass spectrometry and comprehensive two-dimensional gas chromatography coupled to tandem mass spectrometry along with simplified methods of samples preparation to evaluate the differences and advantages of these analytical techniques to better understand the development of the organic matter in this basin without altering the normal distribution of the compounds in the samples. As a result, the geochemical parameters calculated by comprehensive two-dimensional gas chromatography coupled to tandem mass spectrometry described better the origin, maturity, and biodegradation of both samples probably by increased selectivity, resolution, and sensitivity inherent of the multidimensional technique. Additionally, the detection of the compounds such as, the C(14α-) homo-26-nor-17α-hopane series, diamoretanes, nor-spergulanes, C19 -C26 A-nor-steranes and 4α-methylsteranes resolved and detected by comprehensive two-dimensional gas chromatography coupled to tandem mass spectrometry were key to classify and differentiate these lacustrine samples according to their maturity and deposition conditions. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wang, Zhaokun; Zhang, Xue; Jiang, Shenmeng; Guo, Xingjie
2018-04-01
In this work, the magnetic multiwalled carbon nanotubes (Mag-MWCNTs) were prepared by self-assembly method and characterized by scanning electron microscopy, X-ray powder diffraction, energy dispersive X-ray and vibrating sample magnetometer. Then, these synthetic Mag-MWCNTs were used as sorbents to extract five β-blockers (atenolol, metoprolol, esmolol, pindolol and arotinolol) by magnetic solid-phase extraction. The target analytes adsorbed on Mag-MWCNTs were eluted and determined on a chiral α-acid glycoprotein column coupled with a triple quadrupole mass spectrometry. Eventually, the proposed method was applied to the analysis of the enantiomeric composition of the studied β-blockers in three environmental samples, including river water, influent wastewater and effluent wastewater. Method detection and quantification limits for all enantiomers were in the range of 0.50-1.45 and 1.63-3.75ng/L, respectively. Satisfactory recovery (82.9-95.6%), good intra-day precision (RSD 0.4-10.4%) and inter-day precision (RSD 2.9-7.4%) were also obtained. With numerous advantages such as simplicity of operation, rapidity and high enrichment factor, the newly developed method has potential to assess the enantioselectivity of chiral drugs in ecotoxicity and biodegradation processes, which is also a new expanded application of Mag-MWCNTs in the environmental analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Dresen, S; Ferreirós, N; Gnann, H; Zimmermann, R; Weinmann, W
2010-04-01
The multi-target screening method described in this work allows the simultaneous detection and identification of 700 drugs and metabolites in biological fluids using a hybrid triple-quadrupole linear ion trap mass spectrometer in a single analytical run. After standardization of the method, the retention times of 700 compounds were determined and transitions for each compound were selected by a "scheduled" survey MRM scan, followed by an information-dependent acquisition using the sensitive enhanced product ion scan of a Q TRAP hybrid instrument. The identification of the compounds in the samples analyzed was accomplished by searching the tandem mass spectrometry (MS/MS) spectra against the library we developed, which contains electrospray ionization-MS/MS spectra of over 1,250 compounds. The multi-target screening method together with the library was included in a software program for routine screening and quantitation to achieve automated acquisition and library searching. With the help of this software application, the time for evaluation and interpretation of the results could be drastically reduced. This new multi-target screening method has been successfully applied for the analysis of postmortem and traffic offense samples as well as proficiency testing, and complements screening with immunoassays, gas chromatography-mass spectrometry, and liquid chromatography-diode-array detection. Other possible applications are analysis in clinical toxicology (for intoxication cases), in psychiatry (antidepressants and other psychoactive drugs), and in forensic toxicology (drugs and driving, workplace drug testing, oral fluid analysis, drug-facilitated sexual assault).
Di Corcia, D; Lisi, S; Pirro, V; Gerace, E; Salomone, A; Vincenti, M
2013-05-15
A simple and extremely fast procedure for the quantitative determination in oral fluid samples of 44 substances, including the most common drugs of abuse and several pharmaceutical drugs, was developed and fully validated. Preliminary sample treatment was limited to protein precipitation. The resulting acetonitrile solution was directly injected into an ultra-high performance liquid chromatograph (UHPLC) equipped with a C18 column (100mm×2.1mm, 1.7μm). The mobile phase eluted with linear gradient (water/formic acid 5mM: acetonitrile/formic acid 5mM; v:v) from 98:2 to 0:100 in 5.0min, followed by isocratic elution at 100% B for 1.0min. The flow rate was 0.6mL/min and the total run time was 9.0min including re-equilibration at the initial conditions. The analytes were revealed by a triple quadrupole mass spectrometer operating in the selected reaction monitoring mode. The method proved to be simple, accurate, rapid and highly sensitive, allowing the simultaneous detection of all compounds. The ease of sample treatment, together with the wide range of detectable substances, all with remarkable analytical sensitivity, make this procedure ideal for the screening of large populations in several forensic and clinical contexts, whenever oral fluid sampling has to be preferred to blood sampling, as for example in short retrospective investigations. Copyright © 2013 Elsevier B.V. All rights reserved.
Pérez-Fernández, Virginia; Marchese, Stefano; Gentili, Alessandra; García, María Ángeles; Curini, Roberta; Caretti, Fulvia; Perret, Daniela
2014-11-07
This paper describes development and validation of a new method for the simultaneous determination of six antithyroid drugs (ATDs) in surface waters by using liquid chromatography-triple quadrupole mass spectrometry (LC-MS/MS). Target compounds include two ATD classes: thiouracil derivatives (thiouracil (TU), methyl-thiouracil (MTU), propyl-thiouracil (PTU), phenyl-thiouracil (PhTU)) and imidazole derivatives (tapazole (TAP), and mercaptobenzimidazole (MBI)). Sensitivity and selectivity of the LC-multiple reaction monitoring (MRM) analysis allowed applying a simple pre-concentration procedure and "shooting" the concentrated sample into the LC-MS/MS system without any other treatment. Recoveries were higher than 75% for all analytes. Intra-day precision and inter-day precision, calculated as relative standard deviation (RSD), were below 19 and 22%, respectively. Limits of detection (LODs) ranged from 0.05 to 0.25 μg/L; limits of quantitation (LOQs) varied between 0.15 and 0.75 μg/L. The validated method was successfully applied to the analysis of ATD residues in surface water samples collected from the Tiber River basin and three lakes of Lazio (central Italy). The analytes were quantified based on matrix-matched calibration curves with mercaptobenzimidazole-d4 (MBI-d4) as the internal standard (IS). The most widespread compound was TAP, one of the most common ATDs used in human medicine, but also TU and MBI were often detected in the analysed samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Development of MRM-based assays for the absolute quantitation of plasma proteins.
Kuzyk, Michael A; Parker, Carol E; Domanski, Dominik; Borchers, Christoph H
2013-01-01
Multiple reaction monitoring (MRM), sometimes called selected reaction monitoring (SRM), is a directed tandem mass spectrometric technique performed on to triple quadrupole mass spectrometers. MRM assays can be used to sensitively and specifically quantify proteins based on peptides that are specific to the target protein. Stable-isotope-labeled standard peptide analogues (SIS peptides) of target peptides are added to enzymatic digests of samples, and quantified along with the native peptides during MRM analysis. Monitoring of the intact peptide and a collision-induced fragment of this peptide (an ion pair) can be used to provide information on the absolute peptide concentration of the peptide in the sample and, by inference, the concentration of the intact protein. This technique provides high specificity by selecting for biophysical parameters that are unique to the target peptides: (1) the molecular weight of the peptide, (2) the generation of a specific fragment from the peptide, and (3) the HPLC retention time during LC/MRM-MS analysis. MRM is a highly sensitive technique that has been shown to be capable of detecting attomole levels of target peptides in complex samples such as tryptic digests of human plasma. This chapter provides a detailed description of how to develop and use an MRM protein assay. It includes sections on the critical "first step" of selecting the target peptides, as well as optimization of MRM acquisition parameters for maximum sensitivity of the ion pairs that will be used in the final method, and characterization of the final MRM assay.
Xie, Honglei; Li, Chun; Liu, Ning
2013-08-01
The method for analysing sialic acid in infant formulas by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) has been established. Sialic acid in milk was released via acid hydrolysis, and purified by an HLB solid phase extraction cartridge. The UPLC separation was performed on an ACQUITY UPLC BEH HILIC column (50 mm x 2.1 mm, 1.7 microm) utilizing a gradient elution program of acetonitrile and water (containing 0.1% formic acid) as the mobile phases at a flow rate of 0.25 mL/min. Injection volume and column temperature were set at 5 microL and 30 degrees C, respectively. The identification and quantification were achieved by using electrospray ionisation (ESI)-MS/MS in positive ion mode and multiple reaction monitoring (MRM) mode. The linear range was from 0.05 to 5.0 mg/L for sialic acid and the correlation coefficient (R(2)) was greater than 0.99. The average recoveries spiked at the four concentration levels of 0.1, 0.5, 2.5 and 5.0 mg/L ranged between 84.3% and 98.9% with the relative standard deviations from 4.9% to 8.2%. The limit of detection was 0.01 mg/L. Therefore, this method has the characteristics of simple operation, high reproducibility and sensitivity. It can be widely applied to determine the total contents of sialic acid in infant formula, cow milk and human milk.
Gionfriddo, Emanuela; Naccarato, Attilio; Sindona, Giovanni; Tagarelli, Antonio
2014-07-04
In this work, the capabilities of solid phase microextraction were exploited in a fully optimized SPME-GC-QqQ-MS analytical approach for hydrazine assay. A rapid and easy method was obtained by a simple derivatization reaction with propyl chloroformate and pyridine carried out directly in water samples, followed by automated SPME analysis in the same vial without further sample handling. The affinity of the different derivatized compounds obtained towards five commercially available SPME coatings was evaluated, in order to achieve the best extraction efficiency. GC analyses were carried out using a GC-QqQ-MS instrument in selected reaction monitoring (SRM) acquisition mode which has allowed the achievement of high specificity by selecting appropriate precursor-product ion couples improving the capability in analyte identification. The multivariate approach of experimental design was crucial in order to optimize derivatization reaction, SPME process and tandem mass spectrometry parameters. Accuracy of the proposed protocol, tested at 60, 200 and 800 ng L(-1), provided satisfactory values (114.2%, 83.6% and 98.6%, respectively), whereas precision (RSD%) at the same concentration levels were of 10.9%, 7.9% and 7.7% respectively. Limit of detection and quantification of 4.4 and 8.3 ng L(-1) were obtained. The reliable application of the proposed protocol to real drinking water samples confirmed its capability to be used as analytical tool for routine analyses. Copyright © 2014 Elsevier B.V. All rights reserved.
Vanol, Pravin G; Singhal, Puran; Shah, Priyanka A; Shah, Jaivik V; Shrivastav, Pranav S; Sanyal, Mallika
2016-08-01
A rapid and sensitive ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method is described for determination of letrozole in human plasma. Following solid phase extraction (SPE) of letrozole and letrozole-d4 on Orochem DVB-LP cartridges, chromatography was performed on Acquity UPLC BEH C 18 (50 mm×2.1 mm, 1.7 µm) column using methanol-0.1% formic acid in water (85:15, v/v) as the mobile phase. Detection was carried out on a triple quadrupole mass spectrometer with an electrospray source, operated under positive ionization mode. Quantitation of letrozole and letrozole-d4 was done using multiple reaction monitoring (MRM) following the transitions at m/z 286.2→217.0 and m/z 290.2→221.0, respectively. The calibration plots were linear through the concentration range of 0.10-100 ng/mL ( r 2 ≥0.9990) using 100 µL human plasma. The extraction recovery of letrozole ranged from 94.3% to 96.2% and the intra-batch and inter-batch precision was ≤5.2%. The method was successfully applied to a bioequivalence study of letrozole after oral administration of 2.5 mg tablet formulation to 16 healthy postmenopausal Indian women. The assay reproducibility was also established through incurred sample reanalysis (ISR) of 74 subject samples.
Chang, Chunxin; Chen, Minjian; Gao, Jiawei; Luo, Jia; Wu, Keqin; Dong, Tianyu; Zhou, Kun; He, Xiaowei; Hu, Weiyue; Wu, Wei; Lu, Chuncheng; Hang, Bo; Meeker, John D; Wang, Xinru; Xia, Yankai
2017-05-01
Although various pesticides were used globally, the pesticides profiles in human blood serum remain largely unknown. We determined pesticide exposure profiles using solid-phase extraction and gas chromatography tandem with triple quadrupole mass spectrometry in 200 human blood serum samples from the adult population in Jiangsu Province, China. A systematic and comprehensive literature review was carried out to identify the articles investigating pesticide exposure and compare exposure data. Of the 88 pesticides, 76 were found in the blood serum of the population in Jiangsu Province. To the best of our knowledge, 58 pesticides were reported in human blood serum for the first time, and among these pesticides, parathion-methyl, pyrimethanil, fluacrypyrim, simazine, cloquintocet-mexyl and barban were debatable in more than half of the samples. By statistical comparison of the blood serum levels of pesticides between this study and other countries, we found the levels of several organochlorine pesticides were significantly higher in the female population of Jiangsu Province. Health risks related to the pesticide profiling were then revealed, which identified higher carcinogenic toxicity and teratogenic toxicity risk in the female adults of Jiangsu Province caused by organochlorine pesticide exposure. This study not only provides a high-throughput pesticide screening method for future studies of the exposome, but also presents the first human data on exposure to a number of pesticides. It may provide a knowledge database for the risk assessment and management of the pesticides. Copyright © 2017 Elsevier Ltd. All rights reserved.
Patteet, Lisbeth; Maudens, Kristof E; Sabbe, Bernard; Morrens, Manuel; De Doncker, Mireille; Neels, Hugo
2014-02-15
Therapeutic drug monitoring of antipsychotics is important for optimizing therapy, explaining adverse effects, non-response or poor compliance. We developed a UHPLC-MS/MS method for quantification of 16 commonly used and recently marketed antipsychotics and 8 metabolites in serum. After liquid-liquid extraction using methyl tert-butyl ether, analysis was performed on an Agilent Technologies 1290 Infinity LC system coupled with an Agilent Technologies 6460 Triple Quadrupole MS. Separation with a C18 column and gradient elution at 0.5 mL/min resulted in a 6-min run-time. Detection was performed in dynamic MRM, monitoring 3 ion transitions per compound. Isotope labeled internal standards were used for every compound, except for bromperidol and levosulpiride. Mean recovery was 86.8%. Matrix effects were -18.4 to +9.1%. Accuracy ranged between 91.3 and 107.0% at low, medium and high concentrations and between 76.2 and 113.9% at LLOQ. Within-run precision was <15% (CV), except for asenapine and hydroxy-iloperidone. Between-run precision was aberrant only for 7-hydroxy-N-desalkylquetiapine, asenapine and reduced haloperidol. No interferences were found. No problems of instability were observed, even for olanzapine. The method was successfully applied on patient samples. The liquid-liquid extraction and UHPLC-MS/MS technique allows robust target screening and quantification of 23 antipsychotics and metabolites. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Ren, Jianhua; Tian, Yuan; Hossain, Ekram; Connolly, Michael D.
2016-04-01
Peptoids are peptide-mimicking oligomers consisting of N-alkylated glycine units. The fragmentation patterns for six singly and doubly protonated model peptoids were studied via collision-induced dissociation tandem mass spectrometry. The experiments were carried out on a triple quadrupole mass spectrometer with an electrospray ionization source. Both singly and doubly protonated peptoids were found to fragment mainly at the backbone amide bonds to produce peptoid B-type N-terminal fragment ions and Y-type C-terminal fragment ions. However, the relative abundances of B- versus Y-ions were significantly different. The singly protonated peptoids fragmented by producing highly abundant Y-ions and lesser abundant B-ions. The Y-ion formation mechanism was studied through calculating the energetics of truncated peptoid fragment ions using density functional theory and by controlled experiments. The results indicated that Y-ions were likely formed by transferring a proton from the C-H bond of the N-terminal fragments to the secondary amine of the C-terminal fragments. This proton transfer is energetically favored, and is in accord with the observation of abundant Y-ions. The calculations also indicated that doubly protonated peptoids would fragment at an amide bond close to the N-terminus to yield a high abundance of low-mass B-ions and high-mass Y-ions. The results of this study provide further understanding of the mechanisms of peptoid fragmentation and, therefore, are a valuable guide for de novo sequencing of peptoid libraries synthesized via combinatorial chemistry.
Min, Jee Sun; Kim, Jiseon; Kim, Jung Ho; Kim, Doyun; Zheng, Yu Fen; Park, Ji Eun; Lee, Wooin; Bae, Soo Kyung
2017-11-30
A highly sensitive and rapid LC-MS/MS method was developed and validated to determine the levels of carfilzomib in mice plasma by using chlorpropamide as an internal standard. Carfilzomib and chlorpropamide were extracted from 5 μL of plasma after protein precipitation with acetonitrile. Chromatographic separation was performed on Phenomenex Luna C 18 column (50×2.0mm id, 3μm). The mobile phase consisted of 0.1% formic acid in acetonitrile -0.1% formic acid in water (1:1v/v) and the flow rate was 0.3mL/min. The total chromatographic run time was 2.5min. Detection was performed on a triple quadrupole mass spectrometer equipped with positive-ion electrospray ionization by selected reaction monitoring of the transitions at m/z 720.20>100.15 (for carfilzomib) and m/z 277.05>111.05 (for the internal standard). The lower limit of quantification was 0.075ng/mL and the linear range was 0.075-1250ng/mL (r≥0.9974). All validation data, including selectivity, precision, accuracy, matrix effect, recovery, dilution integrity, stability, and incurred sample reanalysis, were well within acceptance limits. This newly developed bioanalytical method was simple, highly sensitive, required only a small volume of plasma, and was suitable for application in pharmacokinetic studies in mice that used serial blood sampling. Copyright © 2017 Elsevier B.V. All rights reserved.
Leveque, Nathalie L; Charman, William N; Chiu, Francis C K
2006-01-18
A sensitive, simple and fast liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method for the determination of proguanil (PG) and its metabolites, cycloguanil (CG) and 1-(4-chlorophenyl)biguanide (4CPB), was developed and validated over a concentration range of 1-2000 ng/mL using only 50 microL of blood or plasma. After a simple solvent precipitation procedure, the supernatant was analysed directly by HPLC-MS/MS. Separation was achieved using an ethyl-linked phenyl reverse phase column with polar endcapping with an acetonitrile-water-formic acid gradient. Mass spectrometry was performed using a triple quadrupole mass spectrometer operating in positive electrospray ionization mode. The elution of PG (254.07-->169.99), CG (252.12-->195.02) and 4CPB (212.06-->153.06) was monitored using selected reaction monitoring. The three compounds and the internal standard (chloroproguanil) were well separated by HPLC and no interfering peaks were detected at the usual concentrations found in blood and plasma. The limit of quantification of PG and CG was 1 ng/mL and 5 ng/mL for 4CPB in rat blood and plasma. The extraction efficiency of PG, CG and 4CPB from rat blood and plasma was higher than 73%. The intra- and inter-assay variability of PG, CG and 4CPB were within 12% and the accuracy within +/-5%. This new assay offers higher sensitivity and a much shorter run time over earlier methods.
Xu, Bin; Zhang, Dong-Yang; Liu, Ze-Yu; Zhang, Ying; Liu, Li; Li, Long; Liu, Charles C; Wu, Guo-Hua
2015-10-10
A new method based on a Direct Analysis in Real Time (DART) ionization source coupled with triple quadrupole tandem mass spectrometry has been developed for rapid qualitative and quantitative analyses of 1-deoxynojirimycin (DNJ) in mulberry leaves. Two ions produced from DNJ, [M+H](+) (m/z 164) and [M-2H+H](+) (m/z 162), are observed using DART-MS in the positive ion mode. The peak areas of the two selected ions monitoring (SIM) signals of ([M+H](+) (m/z 164) and [M-2H+H](+) (m/z 162)) are integrated to determine the peak area for quantitative analyses. A reasonable linear regression equation is obtained in the range of 1.01 to 40.50 μg/mL, with a linear coefficient (R(2)) of 0.996. The limits of detection (LOD) and quantification (LOQ) of the method are 0.25 and 0.80 μg/mL, respectively. The range of recovery is shown to be 87.73-95.61%. The results derived from the developed DART-MS method are in good agreement with those from the conventional HPLC-FLD method. By contrast, DART-MS in SIM mode is a simple, rapid and high-throughput approach for the determination of the DNJ content in mulberry leaves. The present method is advantageous for the rapid screening of mulberry leaves containing high DNJ contents. Copyright © 2015 Elsevier B.V. All rights reserved.
Garrido, Eva; Camacho-Muñoz, Dolores; Martín, Julia; Santos, Antonio; Santos, Juan Luis; Aparicio, Irene; Alonso, Esteban
2016-12-01
Guadiamar River is located in the southwest of the Iberian Peninsula and connects two protected areas in the South of Spain: Sierra Morena and Doñana National Park. It is sited in an area affected by urban, industrial and agriculture sewage pollution and with tradition on intensive mining activities. Most of the studies performed in this area have been mainly focused on the presence of heavy metals and, until now, little is known about the occurrence of other contaminants such as emerging organic pollutants (EOPs). In this work, an analytical method has been optimized and validated for monitoring of forty-seven EOPs in surface water. The analytical method has been applied to study the distribution and environmental risk of these pollutants in Guadiamar River basin. The analytical method was based on solid-phase extraction and determination by liquid chromatography-triple quadrupole-tandem mass spectrometry. The 60 % of the target compounds were found in the analyzed samples. The highest concentrations were found for two plasticizers (bisphenol A and di(2-ethyhexyl)phthalate, mean concentration up to 930 ng/L) and two pharmaceutical compounds (caffeine (up to 623 ng/L) and salicylic acid (up to 318 ng/L)). This study allowed to evaluate the potential sources (industrial or urban) of the studied compounds and the spatial distribution of their concentrations along the river. Environmental risk assessment showed a major risk on the south of the river, mainly due to discharges of wastewater effluents.
Gasperotti, Mattia; Masuero, Domenico; Guella, Graziano; Mattivi, Fulvio; Vrhovsek, Urska
2014-10-01
An increasing number of studies have concerned the profiling of polyphenol microbial metabolites, especially in urine or plasma, but only a few have regarded their accurate quantification. This study reports on a new ultra-performance liquid chromatography tandem mass spectrometry method with electrospray ionisation (UHPLC-ESI-MS/MS) using a simple clean-up step with solid phase extraction (SPE) and validation on different biological matrices. The method was tested with spiked samples of liver, heart, kidneys, brain, blood and urine. The purification procedure, after the evaluation of three different cartridges, makes it possible to obtain cleaner samples and better quantification of putative trace metabolites, especially related to dietary studies, with concentrations below ng/g in tissue and for urine and blood, starting from ng/ml. Limits of detection and linear range were also assessed using mixed polyphenol metabolite standards. Short chromatographic separation was carried out for 23 target compounds related to the polyphenol microbial metabolism, coupled with a triple quadrupole mass spectrometer for their accurate quantification. By analysing different spiked biological samples we were able to test metabolite detection in the matrix and validate the overall recovery of the method, from purification to quantification. The method developed can be successfully applied and is suitable for high-throughput targeted metabolomics analysis related to nutritional intervention, or the study of the metabolic mechanism in response to a polyphenol-rich diet. Copyright © 2014 Elsevier B.V. All rights reserved.
Cocci, Andrea; Zuppi, Cecilia; Persichilli, Silvia
2013-01-01
Objective. 25-hydroxyvitamin D2/D3 (25-OHD2/D3) determination is a reliable biomarker for vitamin D status. Liquid chromatography-tandem mass spectrometry was recently proposed as a reference method for vitamin D status evaluation. The aim of this work is to compare two commercial kits (Chromsystems and PerkinElmer) for 25-OHD2/D3 determination by our entry level LC-MS/MS. Design and Methods. Chromsystems kit adds an online trap column to an HPLC column and provides atmospheric pressure chemical ionization, isotopically labeled internal standard, and 4 calibrator points. PerkinElmer kit uses a solvent extraction and protein precipitation method. This kit can be used with or without derivatization with, respectively, electrospray and atmospheric pressure chemical ionization. For each analyte, there are isotopically labeled internal standards and 7 deuterated calibrator points. Results. Performance characteristics are acceptable for both methods. Mean bias between methods calculated on 70 samples was 1.9 ng/mL. Linear regression analysis gave an R 2 of 0.94. 25-OHD2 is detectable only with PerkinElmer kit in derivatized assay option. Conclusion. Both methods are suitable for routine. Chromsystems kit minimizes manual sample preparation, requiring only protein precipitation, but, with our system, 25-OHD2 is not detectable. PerkinElmer kit without derivatization does not guarantee acceptable performance with our LC-MS/MS system, as sample is not purified online. Derivatization provides sufficient sensitivity for 25-OHD2 detection. PMID:23555079
Sun, Jing; Cao, Ling; Feng, Youlong; Tan, Li
2014-11-01
The compounds with similar structure often have similar pharmacological activities. So it is a trend for illegal addition that new derivatives of effective drugs are synthesized to avoid the statutory test. This bring challenges to crack down on illegal addition behavior, however, modified derivatives usually have similar product ions, which allow for precursor ion scanning. In this work, precursor ion scanning mode of a triple quadrupole mass spectrometer was first applied to screen illegally added drugs in complex matrix such as Chinese traditional patent medicines and healthy foods. Phosphodiesterase-5 inhibitors were used as experimental examples. Through the analysis of the structure and mass spectrum characteristics of the compounds, phosphodiesterase-5 inhibitors were classified, and their common product ions were screened by full scan of product ions of typical compounds. Then high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method with precursor ion scanning mode was established based on the optimization of MS parameters. The effect of mass parameters and the choice of fragment ions were also studied. The method was applied to determine actual samples and further refined. The results demonstrated that this method can meet the need of rapid screening of unknown derivatives of phosphodiesterase-5 inhibitors in complex matrix, and prevent unknown derivatives undetected. This method shows advantages in sensitivity, specificity and efficiency, and is worth to be further investigated.
Kwok, Wai Him; Choi, Timmy L S; So, Pui-Kin; Yao, Zhong-Ping; Wan, Terence S M
2017-02-01
Xenon can activate the hypoxia-inducible factors (HIFs). As such, it has been allegedly used in human sports for increasing erythropoiesis. Krypton, another noble gas with reported narcosis effect, can also be expected to be a potential and less expensive erythropoiesis stimulating agent. This has raised concern about the misuse of noble gases as doping agents in equine sports. The aim of the present study is to establish a method for the simultaneous detection of xenon and krypton in equine plasma for the purpose of doping control. Xenon- or krypton-fortified equine plasma samples were prepared according to reported protocols. The target noble gases were simultaneously detected by gas chromatography-triple quadrupole mass spectrometry using headspace injection. Three xenon isotopes at m/z 129, 131, and 132, and four krypton isotopes at m/z 82, 83, 84, and 86 were targeted in selected reaction monitoring mode (with the precursor ions and product ions at identical mass settings), allowing unambiguous identification of the target analytes. Limits of detection for xenon and krypton were about 19 pmol/mL and 98 pmol/mL, respectively. Precision for both analytes was less than 15%. The method has good specificity as background analyte signals were not observed in negative equine plasma samples (n = 73). Loss of analytes under different storage temperatures has also been evaluated. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Lowenthal, Mark S; Yen, James; Bunk, David M; Phinney, Karen W
2010-05-01
An isotope-dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) measurement procedure was developed to accurately quantify amino acid concentrations in National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 2389a-amino acids in 0.1 mol/L hydrochloric acid. Seventeen amino acids were quantified using selected reaction monitoring on a triple quadrupole mass spectrometer. LC-MS/MS results were compared to gravimetric measurements from the preparation of SRM 2389a-a reference material developed at NIST and intended for use in intra-laboratory calibrations and quality control. Quantitative mass spectrometry results and gravimetric values were statistically combined into NIST-certified mass fraction values with associated uncertainty estimates. Coefficients of variation (CV) for the repeatability of the LC-MS/MS measurements among amino acids ranged from 0.33% to 2.7% with an average CV of 1.2%. Average relative expanded uncertainty of the certified values including Types A and B uncertainties was 3.5%. Mean accuracy of the LC-MS/MS measurements with gravimetric preparation values agreed to within |1.1|% for all amino acids. NIST SRM 2389a will be available for characterization of routine methods for amino acid analysis and serves as a standard for higher-order measurement traceability. This is the first time an ID LC-MS/MS methodology has been applied for quantifying amino acids in a NIST SRM material.
2013-09-30
ion modes. The resulting chromatograms were then processed using XCMS (alignment and peak picking ). The data were processed with in-house...UHPLC liquid chromatography Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry ( MS ). A standard method was developed for rapid analysis...extraction protocols and then implemented LC- MS / MS analyses on our Thermo Fisher Scientific TSQ Vantage triple quadrupole mass spectrometer. This
Du, Gang; Zhao, Haiyu; Song, Yuelin; Zhang, Qingwen; Wang, Yitao
2011-10-01
A high-performance liquid chromatography (HPLC) coupled with triple quadrupole mass spectrometry (MS/MS) method was developed for rapid determination of 13 isoflavones in Radix puerariae. A novel shell-type column, namely Kinetex core-shell C(18) column (50 mm×2.1 mm id, 2.6 μm), and gradient elution were used during the analysis. The chromatographic peaks of 13 investigated compounds were identified by comparing their retention time and MS data with the related reference compounds. Multiple-reaction monitoring (MRM) was employed for the quantitative analysis with negative ionization mode. All calibration curves showed good linearity (r(2)>0.9990) within test ranges. The LOD and LOQ were lower than 0.017 and 0.873 μg/mL on column, respectively. The intra- and inter-day precisions for 13 analytes were <1.17 and 2.17%, respectively, and the recoveries were 93.1-104.4%. The validated method was applied for quantitative analysis of 13 isoflavones in 7 species of Radix puerariae. The result demonstrated that HPLC-MS/MS system with Kinetex column could be a promising analytical tool for the determination of isoflavones in traditional Chinese medicines, which is helpful for comprehensive evaluation of quality of R. puerariae. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Takeda, Hiroaki; Izumi, Yoshihiro; Takahashi, Masatomo; Paxton, Thanai; Tamura, Shohei; Koike, Tomonari; Yu, Ying; Kato, Noriko; Nagase, Katsutoshi; Shiomi, Masashi; Bamba, Takeshi
2018-05-03
Lipidomics, the mass spectrometry-based comprehensive analysis of lipids, has attracted attention as an analytical approach to provide novel insight into lipid metabolism and to search for biomarkers. However, an ideal method for both comprehensive and quantitative analysis of lipids has not been fully developed. Herein, we have proposed a practical methodology for widely-targeted quantitative lipidome analysis using supercritical fluid chromatography fast-scanning triple-quadrupole mass spectrometry (SFC/QqQMS) and theoretically calculated a comprehensive lipid multiple reaction monitoring (MRM) library. Lipid classes can be separated by SFC with a normal phase diethylamine-bonded silica column with high-resolution, high-throughput, and good repeatability. Structural isomers of phospholipids can be monitored by mass spectrometric separation with fatty acyl-based MRM transitions. SFC/QqQMS analysis with an internal standard-dilution method offers quantitative information for both lipid class and individual lipid molecular species in the same lipid class. Additionally, data acquired using this method has advantages including reduction of misidentification and acceleration of data analysis. Using the SFC/QqQMS system, alteration of plasma lipid levels in myocardial infarction-prone rabbits to the supplementation of eicosapentaenoic acid was first observed. Our developed SFC/QqQMS method represents a potentially useful tool for in-depth studies focused on complex lipid metabolism and biomarker discovery. Published under license by The American Society for Biochemistry and Molecular Biology, Inc.
Hu, Zhe-Yi; Parker, Robert B.; Herring, Vanessa L.; Laizure, S. Casey
2012-01-01
Dabigatran etexilate (DABE) is an oral prodrug that is rapidly converted by esterases to dabigatran (DAB), a direct inhibitor of thrombin. To elucidate the esterase-mediated metabolic pathway of DABE, a high-performance liquid chromatography/mass spectrometer (LC-MS/MS)-based metabolite identification and semi-quantitative estimation approach was developed. To overcome the poor full-scan sensitivity of conventional triple quadrupole mass spectrometry, precursor-product ion pairs were predicted, to search for the potential in vitro metabolites. The detected metabolites were confirmed by the product ion scan. A dilution method was introduced to evaluate the matrix effects of tentatively identified metabolites without chemical standards. Quantitative information on detected metabolites was obtained using ‘metabolite standards’ generated from incubation samples that contain a high concentration of metabolite in combination with a correction factor for mass spectrometry response. Two in vitro metabolites of DABE (M1 and M2) were identified, and quantified by the semi-quantitative estimation approach. It is noteworthy that CES1 convert DABE to M1 while CES2 mediates the conversion of DABE to M2. M1 (or M2) was further metabolized to DAB by CES2 (or CES1). The approach presented here provides a solution to a bioanalytical need for fast identification and semi-quantitative estimation of CES metabolites in preclinical samples. PMID:23239178
Wang, Shengnan; Hua, Yujiao; Zou, Lisi; Liu, Xunhong; Yan, Ying; Zhao, Hui; Luo, Yiyuan; Liu, Juanxiu
2018-02-01
Scrophulariae Radix is one of the most popular traditional Chinese medicines (TCMs). Primary processing of Scrophulariae Radix is an important link which closely related to the quality of products in this TCM. The aim of this study is to explore the influence of different processing methods on chemical constituents in Scrophulariae Radix. The difference of chemical constituents in Scrophulariae Radix processed by different methods was analyzed by using ultra fast liquid chromatography-triple quadrupole-time of flight mass spectrometry coupled with principal component analysis and orthogonal partial least squares discriminant analysis. Furthermore, the contents of 12 index differential constituents in Scrophulariae Radix processed by different methods were simultaneously determined by using ultra fast liquid chromatography coupled with triple quadrupole-linear ion trap mass spectrometry. Gray relational analysis was performed to evaluate the different processed samples according to the contents of 12 constituents. All of the results demonstrated that the quality of Scrophulariae Radix processed by "sweating" method was better. This study will provide the basic information for revealing the change law of chemical constituents in Scrophulariae Radix processed by different methods and facilitating selection of the suitable processing method of this TCM. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Amendola, Luca; Cortese, Maria; Vinatoru, Daniela; Sposato, Silvana; Insogna, Susanna
2017-07-04
Tributyltin (TBT) and pentachlorophenol (PCP) are listed as priority substances that warrant monitoring in the European Water Framework Directive (WFD 2000/60/CE), since TBT and PCP were identified as environmental endocrine disruptors and exhibit considerable toxicity toward both aquatic organisms and mammals even at very low levels. This paper shows a novel approach to analyze underivatized tributyltin (TBT) and pentachlorophenol (PCP) in seawater based on capillary gas chromatography-triple quadrupole mass spectrometry. The optimized extraction method for TBT an PCP in water involved liquid-liquid microextraction with toluene. The reduced extract was added with a solvent mix, composed of methanol and trimethylsilyl derivatives of methanol (MeOTMS), that allowed good chromatographic resolution of underivatized TBT and PCP, interacting as a lubricant along the glass liner during the injection phase. The proposed method showed good linearity and repeatability (RSD%<20% at 0.05 ng L -1 for TBT and 0.2 μg L -1 for PCP). The overall recoveries were 74% and 106% for TBT and PCP, respectively. Very low quantification limits that met the strict statutory and regulatory demands were achieved: 0.002 ng L -1 for TBT and 0.050 μg L -1 for PCP. Copyright © 2017 Elsevier B.V. All rights reserved.
Gravitational waves in the spectral action of noncommutative geometry
NASA Astrophysics Data System (ADS)
Nelson, William; Ochoa, Joseph; Sakellariadou, Mairi
2010-10-01
The spectral triple approach to noncommutative geometry allows one to develop the entire standard model (and supersymmetric extensions) of particle physics from a purely geometry standpoint and thus treats both gravity and particle physics on the same footing. The bosonic sector of the theory contains a modification to Einstein-Hilbert gravity, involving a nonconformal coupling of curvature to the Higgs field and conformal Weyl term (in addition to a nondynamical topological term). In this paper we derive the weak-field limit of this gravitational theory and show that the production and dynamics of gravitational waves are significantly altered. In particular, we show that the graviton contains a massive mode that alters the energy lost to gravitational radiation, in systems with evolving quadrupole moment. We explicitly calculate the general solution and apply it to systems with periodically varying quadrupole moments, focusing, in particular, on the well-known energy loss formula for circular binaries.
Treatment planning capability assessment of a beam shaping assembly for accelerator-based BNCT.
Herrera, M S; González, S J; Burlon, A A; Minsky, D M; Kreiner, A J
2011-12-01
Within the frame of an ongoing project to develop a folded Tandem-Electrostatic-Quadrupole accelerator facility for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT) a theoretical study was performed to assess the treatment planning capability of different configurations of an optimized beam shaping assembly for such a facility. In particular this study aims at evaluating treatment plans for a clinical case of Glioblastoma. Copyright © 2011 Elsevier Ltd. All rights reserved.
Zhang, Li; Liu, Haiyu; Qin, Lingling; Zhang, Zhixin; Wang, Qing; Zhang, Qingqing; Lu, Zhiwei; Wei, Shengli; Gao, Xiaoyan; Tu, Pengfei
2015-02-01
A global chemical profiling based quality evaluation approach using ultra performance liquid chromatography with tandem quadrupole time-of-flight mass spectrometry was developed for the quality evaluation of three rhubarb species, including Rheum palmatum L., Rheum tanguticum Maxim. ex Balf., and Rheum officinale Baill. Considering that comprehensive detection of chemical components is crucial for the global profile, a systemic column performance evaluation method was developed. Based on this, a Cortecs column was used to acquire the chemical profile, and Chempattern software was employed to conduct similarity evaluation and hierarchical cluster analysis. The results showed R. tanguticum could be differentiated from R. palmatum and R. officinale at the similarity value 0.65, but R. palmatum and R. officinale could not be distinguished effectively. Therefore, a common pattern based on three rhubarb species was developed to conduct the quality evaluation, and the similarity value 0.50 was set as an appropriate threshold to control the quality of rhubarb. A total of 88 common peaks were identified by their accurate mass and fragmentation, and partially verified by reference standards. Through the verification, the newly developed method could be successfully used for evaluating the holistic quality of rhubarb. It would provide a reference for the quality control of other herbal medicines. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Qin, Zifei; Lin, Pei; Dai, Yi; Yao, Zhihong; Wang, Li; Yao, Xinsheng; Liu, Liyin; Chen, Haifeng
2016-05-01
Allii Macrostemonis Bulbus (named Xiebai in China) is a folk medicine with medicinal values for the treatment of thoracic obstruction and cardialgia, and a food additive as well. However, there is even no quantitative standard for Allii Macrostemonis Bulbus recorded in the current edition of the Chinese Pharmacopeia. Hence, simultaneous assay of multiple components is urgent. In this study, chemometric methods were firstly applied to discover the components with significant fluctuation among multiple Allii Macrostemonis Bulbus samples based on optimized fingerprints. Meanwhile, the major components and main absorbed components in rats were all selected as its representative components. Subsequently, a sensitive method was established for the simultaneous determination of 54 components (15 components for quantification and 39 components for semiquantification) by ultra high performance liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry. Moreover, the validated method was successfully applied to evaluate the quality of multiple samples on the market. It became known that multiple Allii Macrostemonis Bulbus samples varied significantly and showed poor consistency. This work illustrated that the proposed approach could improve the quality of Allii Macrostemonis Bulbus, and it also provided a feasible method for quality evaluation of other traditional Chinese medicines. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhao, Huading; Hu, Xin; Chen, Xiaoqin; Shi, Shuyun; Jiang, Xinyu; Liang, Xuejuan; Chen, Wei; Zhang, Shuihan
2015-06-12
Due to the complexity of natural products, efficient identification of bioactive compounds, especially for minor compounds, would require a huge effort. Here, we developed an effective strategy based on combining major constituents' knockout with high-performance liquid chromatography-diode array detector-quadrupole time-of-flight tandem mass spectrometry (HPLC-DAD-QTOF-MS/MS) to comprehensively identify minor antioxidants in Malus doumeri, one of the longest known and most used tonic plant in Taiwan. First, five major compounds (I-V) in M. doumeri were knocked out by two-step stepwise high-speed countercurrent chromatography (HSCCC). Second, minor antioxidants were screened by 1,1-diphenyl-2-picrylhydrazyl radical-HPLC (DPPH-HPLC) assay. Third, structures of thirty minor antioxidants, including 11 dihydrochalcones, 4 flavanones, 3 flavonols, 2 flavones, 3 aurones and 7 phenolic acids, were unambiguously or tentatively identified by matching their characteristic UV spectra, accurate mass signals and key diagnostic fragment ions with standards or previously reported compounds. Twenty-six of them, as far as was known, were discovered from M. doumeri for the first time. The results indicated that the proposed method was a useful approach to explore minor bioactive compounds from complex natural products. Copyright © 2015 Elsevier B.V. All rights reserved.
Electrospray ionization tandem mass spectrometry of ammonium cationized polyethers.
Nasioudis, Andreas; Heeren, Ron M A; van Doormalen, Irene; de Wijs-Rot, Nicolette; van den Brink, Oscar F
2011-05-01
Quaternary ammonium salts (Quats) and amines are known to facilitate the MS analysis of high molar mass polyethers by forming low charge state adduct ions. The formation, stability, and behavior upon collision-induced dissociation (CID) of adduct ions of polyethers with a variety of Quats and amines were studied by electrospray ionization quadrupole time-of-flight, quadrupole ion trap, and linear ion trap tandem mass spectrometry (MS/MS). The linear ion trap instrument was part of an Orbitrap hybrid mass spectrometer that allowed accurate mass MS/MS measurements. The Quats and amines studied were of different degree of substitution, structure, and size. The stability of the adduct ions was related to the structure of the cation, especially the amine's degree of substitution. CID of singly/doubly charged primary and tertiary ammonium cationized polymers resulted in the neutral loss of the amine followed by fragmentation of the protonated product ions. The latter reveals information about the monomer unit, polymer sequence, and endgroup structure. In addition, the detection of product ions retaining the ammonium ion was observed. The predominant process in the CID of singly charged quaternary ammonium cationized polymers was cation detachment, whereas their doubly charged adduct ions provided the same information as the primary and tertiary ammonium cationized adduct ions. This study shows the potential of specific amines as tools for the structural elucidation of high molar mass polyethers. © American Society for Mass Spectrometry, 2011
2015-01-01
The economy of Peru has grown rapidly since the year 2000. Peru's GDP per capita has nearly tripled since then. In tandem with the economic growth, energy demand has also grown considerably. Peru, which is rich in hydrocarbons, has oil, natural gas, and coal reserves. Despite its increased energy consumption, Peru exports both oil and natural gas.
Targeted Proteomic Quantification on Quadrupole-Orbitrap Mass Spectrometer*
Gallien, Sebastien; Duriez, Elodie; Crone, Catharina; Kellmann, Markus; Moehring, Thomas; Domon, Bruno
2012-01-01
There is an immediate need for improved methods to systematically and precisely quantify large sets of peptides in complex biological samples. To date protein quantification in biological samples has been routinely performed on triple quadrupole instruments operated in selected reaction monitoring mode (SRM), and two major challenges remain. Firstly, the number of peptides to be included in one survey experiment needs to be increased to routinely reach several hundreds, and secondly, the degree of selectivity should be improved so as to reliably discriminate the targeted analytes from background interferences. High resolution and accurate mass (HR/AM) analysis on the recently developed Q-Exactive mass spectrometer can potentially address these issues. This instrument presents a unique configuration: it is constituted of an orbitrap mass analyzer equipped with a quadrupole mass filter as the front-end for precursor ion mass selection. This configuration enables new quantitative methods based on HR/AM measurements, including targeted analysis in MS mode (single ion monitoring) and in MS/MS mode (parallel reaction monitoring). The ability of the quadrupole to select a restricted m/z range allows one to overcome the dynamic range limitations associated with trapping devices, and the MS/MS mode provides an additional stage of selectivity. When applied to targeted protein quantification in urine samples and benchmarked with the reference SRM technique, the quadrupole-orbitrap instrument exhibits similar or better performance in terms of selectivity, dynamic range, and sensitivity. This high performance is further enhanced by leveraging the multiplexing capability of the instrument to design novel acquisition methods and apply them to large targeted proteomic studies for the first time, as demonstrated on 770 tryptic yeast peptides analyzed in one 60-min experiment. The increased quality of quadrupole-orbitrap data has the potential to improve existing protein quantification methods in complex samples and address the pressing demand of systems biology or biomarker evaluation studies. PMID:22962056
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adamson, B. D.; Coughlan, N. J. A.; Markworth, P. B.
An ion mobility mass spectrometry apparatus for investigating the photoisomerization and photodissociation of electrosprayed molecular ions in the gas phase is described. The device consists of a drift tube mobility spectrometer, with access for a laser beam that intercepts the drifting ion packet either coaxially or transversely, followed by a quadrupole mass filter. An ion gate halfway along the drift region allows the instrument to be used as a tandem ion mobility spectrometer, enabling mobility selection of ions prior to irradiation, with the photoisomer ions being separated over the second half of the drift tube. The utility of the devicemore » is illustrated with photoisomerization and photodissociation action spectra of carbocyanine molecular cations. The mobility resolution of the device for singly charged ions is typically 80 and it has a mass range of 100-440 Da, with the lower limit determined by the drive frequency for the ion funnels, and the upper limit by the quadrupole mass filter.« less
Cartelli, D; Vento, V Thatar; Castell, W; Di Paolo, H; Kesque, J M; Bergueiro, J; Valda, A A; Erhardt, J; Kreiner, A J
2011-12-01
The accelerator tubes are essential components of the accelerator. Their function is to transport and accelerate a very intense proton or deuteron beam through the machine, from the ion source to the neutron production target, without significant losses. In this contribution, we discuss materials selected for the tube construction, the procedures used for their assembly and the testing performed to meet the stringent requirements to which it is subjected. Copyright © 2011 Elsevier Ltd. All rights reserved.
Tandem mass spectrometry of coprogen and deferoxamine hydroxamic siderophores.
Simionato, Ana V C; de Souza, Gezimar D; Rodrigues-Filho, Edson; Glick, James; Vouros, Paul; Carrilho, Emanuel
2006-01-01
Mechanisms of fragmentation of hydroxamic siderophores are proposed comparing deuterated and nondeuterated samples. Standard siderophores (e.g. deferoxamine and coprogen) were directly injected into both ion trap and linear quadrupole mass spectrometers with electrospray ionization (ESI). Four and two fragmentation steps were carried out for deferoxamine and coprogen (analyzed by positive and negative ESI, respectively). Deferoxamine cleavages occurred in both peptide and hydroxamic bonds while the coprogen fragmentation pattern is more elaborate, since it contains Fe(III) in its structure.
Jiang, Zhenzuo; Wang, Yuefei; Zheng, Yunfeng; Yang, Jing; Zhang, Lei
2016-08-01
Licorice is among the most popular herbal medicines and frequently used in traditional medicine, food products, and cosmetics. In China, only Glycyrrhiza uralensis Fisch., Glycyrrhiza inflata Bat. and Glycyrrhiza glabra L. are officially used and are usually processed with honey prior to use. To maintain the quality of commercially available herbal products, a simple, rapid, and reliable ultra high performance liquid chromatography with triple quadrupole mass spectrometry was developed to investigate the major active constituents of commercially available licorice products. Nineteen components were accurately determined, including eight triterpenoid saponins, one triterpene, and ten flavonoids. Subsequently, multivariate statistical analysis methods were employed to further explore and interpret the experimental data. The results indicated that liquiritin apioside may be considered as a candidate index for the quality control of licorice as well as 18β-glycyrrhizic acid and liquiritin. In addition, both 18β-glycyrrhizic acid and licorice-saponin G2 can be used for discrimination between crude and honey-processed licorice. Furthermore, using 18β-glycyrrhizic acid and liquiritin as markers, this work revealed that the quality of licorice products may have declined in recent years. This highlights the need for additional effort focused on good agricultural practice during the processing of licorice. In summary, this study provides a valuable reference for the quality assessment of licorice. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Yan, Zhixiang; Chen, Ying; Li, Tianxue; Zhang, Jie; Yang, Xinghao
2012-02-15
Si-Ni-San (SNS) is a widely used traditional Chinese medicine formula (TCMF) in treating various diseases. However, the in vivo integrated metabolism of its multiple components remains unknown. In this paper, a liquid chromatography coupled with diode array detection and triple-quadrupole spectrometry (LC-DAD-MS/MS) method was developed for detection and identification of SNS metabolites in rat plasma and urine at a normal clinical dosage. Accurate structural elucidation was performed using MS/MS, UV data and n-octanol/water partition coefficient. Based on the proposed strategy, 36 absorbed compounds and 29 metabolites in plasma and 33 metabolites in urine were detected by a highly sensitive MRM method. Our results indicated that phase II reactions (e.g., methylation, glucuronidation and sulfation) were the main metabolic pathways of gallic acid and flavanones, while phase I reactions (e.g., hydroxylation) were the major metabolic reaction for triterpenoid saponins. The metabolite profile analysis of SNS provided a comprehensive understanding of the in vivo metabolic fates of constituents in SNS. Moreover, the results in this work demonstrated the present strategy based on the combination of chromatographic, spectrophotometric, mass-spectrometric, and software prediction to detect and identify metabolites was effective and reliable. And such a strategy may also be extended to investigate the metabolism of other TCMF. Copyright © 2011 Elsevier B.V. All rights reserved.
Quantifying Inorganic Arsenic and Other Water-Soluble Arsenic Species in Human Milk by HPLC/ICPMS.
Stiboller, Michael; Raber, Georg; Gjengedal, Elin Lovise Folven; Eggesbø, Merete; Francesconi, Kevin A
2017-06-06
Because the toxicity of arsenic depends on its chemical form, risk assessments of arsenic exposure must consider the type of arsenic compound, and hence they require sensitive and robust methods for their determination. Furthermore, the assessment should include studies on the most vulnerable people within a population, such as newborns and infants, and thus there is a need to quantify arsenic species in human milk. Herein we report a method for the determination of arsenic species at low concentrations in human milk by HPLC/ICPMS. Comparison of single and triple quadrupole mass analysers showed comparable performance, although the triple quadrupole instrument more efficiently overcame the problem of ArCl + interference, from the natural chloride present in milk, without the need for gradient elution HPLC conditions. The method incorporates a protein precipitation step with trifluoroacetic acid followed by addition of dichloromethane or dibromomethane to remove the lipids. The aqueous phase was subjected to anion-exchange and cation-exchange/mixed mode chromatography with aqueous ammonium bicarbonate and pyridine buffer solutions as mobile phases, respectively. For method validation, a human milk sample was spiked with defined amounts of dimethylarsinate, arsenobetaine, and arsenate. The method showed good recoveries (99-103%) with detection limits (in milk) in the range of 10 ng As kg -1 . The method was further tested by analyzing two Norwegian human milk samples where arsenobetaine, dimethylarsinate, and a currently unknown As species were found, but iAs was not detected.
NASA Astrophysics Data System (ADS)
Haettner, Emma; Plaß, Wolfgang R.; Czok, Ulrich; Dickel, Timo; Geissel, Hans; Kinsel, Wadim; Petrick, Martin; Schäfer, Thorsten; Scheidenberger, Christoph
2018-02-01
The combination of in-flight separation with a gas-filled stopping cell has opened a new field for experiments with exotic nuclei. For instance, at the SHIP/SHIPTRAP facility at GSI in Darmstadt high-precision mass measurements of rare nuclei have been successfully performed. In order to extend the reach of SHIPTRAP to exotic nuclei that are produced together with high rates of unwanted reaction products, a novel compact radio frequency quadrupole (RFQ) system has been developed. It implements ion cooling, identification and separation according to mass numbers and bunching capabilities. The system has a total length of one meter only and consists of an RFQ cooler, an RFQ mass filter and an RFQ buncher. A mass resolving power (FWHM) of 240 at a transmission efficiency of 90% has been achieved. The suppression of contaminants from neighboring masses by more than four orders of magnitude has been demonstrated at rates exceeding 106 ions/s. A longitudinal emittance of 0.45 eV μs has been achieved with the RFQ buncher, which will enable improved time-of-flight mass spectrometry downstream of the device. With this triple RFQ system the measurement of e.g. N= Z nuclides in the region up to tin will become possible at SHIPTRAP. The technology is also well suited for other rare-isotope facilities with experimental setups behind a stopping cell, such as the fragment separator FRS with the FRS Ion Catcher at GSI.
NASA Astrophysics Data System (ADS)
Wang, Evelyn H.; Combe, Peter C.; Schug, Kevin A.
2016-05-01
Methods that can efficiently and effectively quantify proteins are needed to support increasing demand in many bioanalytical fields. Triple quadrupole mass spectrometry (QQQ-MS) is sensitive and specific, and it is routinely used to quantify small molecules. However, low resolution fragmentation-dependent MS detection can pose inherent difficulties for intact proteins. In this research, we investigated variables that affect protein and fragment ion signals to enable protein quantitation using QQQ-MS. Collision induced dissociation gas pressure and collision energy were found to be the most crucial variables for optimization. Multiple reaction monitoring (MRM) transitions for seven standard proteins, including lysozyme, ubiquitin, cytochrome c from both equine and bovine, lactalbumin, myoglobin, and prostate-specific antigen (PSA) were determined. Assuming the eventual goal of applying such methodology is to analyze protein in biological fluids, a liquid chromatography method was developed. Calibration curves of six standard proteins (excluding PSA) were obtained to show the feasibility of intact protein quantification using QQQ-MS. Linearity (2-3 orders), limits of detection (0.5-50 μg/mL), accuracy (<5% error), and precision (1%-12% CV) were determined for each model protein. Sensitivities for different proteins varied considerably. Biological fluids, including human urine, equine plasma, and bovine plasma were used to demonstrate the specificity of the approach. The purpose of this model study was to identify, study, and demonstrate the advantages and challenges for QQQ-MS-based intact protein quantitation, a largely underutilized approach to date.
Zhang, Dan; Park, Jin-A; Kim, Seong-Kwan; Cho, Sang-Hyun; Jeong, Daun; Cho, Soo-Min; Yi, Hee; Shim, Jae-Han; Kim, Jin-Suk; Abd El-Aty, A M; Shin, Ho-Chul
2016-02-15
A simple analytical method based on liquid chromatography coupled with triple-quadrupole mass spectrometry was developed for detection of the veterinary drugs flumethasone, dl-methylephedrine, and 2-hydroxy-4,6-dimethylpyrimidine in porcine muscle and pasteurized cow milk. The target drugs were extracted from samples using 10mM ammonium formate in acetonitrile followed by clean-up with n-hexane and primary secondary amine sorbent (PSA). The analytes were separated on an XBridge™ hydrophilic interaction liquid chromatography (HILIC) column using 10mM ammonium formate in ultrapure water and acetonitrile. Good linearity was achieved over the tested concentrations in matrix-fortified calibrations with correlation coefficients (R(2))≥0.9686. Recovery at two spiking levels ranged between 73.62-112.70% with intra- and inter-day precisions of ≤20.33%. The limits of quantification ranged from 2-10ng/g in porcine muscle and pasteurized cow milk. A survey of market samples showed that none of them contained any of the target analytes. Liquid-liquid purification using n-hexane in combination with PSA efficiently removed the interferences during porcine and milk sample extraction. The developed method is sensitive and reliable for detection of the three target drugs in a single chromatographic run. Furthermore, it exhibits high selectivity and low quantification limits for animal-derived food products destined for human consumption. Copyright © 2016 Elsevier B.V. All rights reserved.
Li, Heli; Chen, Dawei; Miao, Hong; Zhao, Yunfeng; Shen, Jianzhong; Wu, Yongning
2015-09-04
A selective and sensitive ultra-high performance liquid chromatography - triple quadrupole mass spectrometry (UHPLC-MS/MS) method coupled with matrix solid phase dispersion (MSPD) extraction was developed for the direct determination of fatty acid esters of 3-chloro-1,2-propanediol (3-MCPD esters) in edible vegetable oils. The method integrated the isotope dilution technique, MSPD extraction and UHPLC - MS/MS analysis with multi-reaction monitoring mode (MRM). Matrix-matched calibration curves showed good linearity within the range of 0.01-10mgL(-1) with the correlation coefficient not less than 0.999. Limits of detection (LODs) and limit of quantification (LOQs) of the 3-MCPD esters fell into the range of 0.0001-0.02mgkg(-1) and 0.0004-0.05mgkg(-1), respectively. The recoveries for the spiked extra virgin olive oils ranged from 94.4% to 108.3%, with the relative standard deviations (RSD) ranging from 0.6% to 10.5%. The method was applied for the oil sample (T2642) of the official Food Analysis Performance Assessment Scheme (FAPAS) in 2014 and other real samples from supermarket, and the results showed that the present method was comparative to the gas chromatography-mass spectrometry (GC-MS) method based on the improved German Society for Fat Science (DGF) standard method C-III 18 (09) except for palm oil. Copyright © 2015. Published by Elsevier B.V.
Zoccali, Mariosimone; Cappello, Simone; Mondello, Luigi
2018-04-27
The present research is focused on the use of a triple quadrupole mass spectrometer (QqQ MS) coupled with flow modulated comprehensive two-dimensional gas chromatography (FM GC × GC) for a multilevel elucidation of biodegradation potentiality of natural marine microbial populations during a bioremediation (biostimulation) treatment. The crude oil used for the evaluation of the bioremediation process, namely Dansk Blend Pier E1, represents a very complex sample. Hence, in order to understand the metabolic activity of microbial populations during the bioremediation process, a GC × GC system was used. The high separation power has allowed a detailed characterization of the different chemical families; moreover, thanks to the high acquisition frequency of the QqQ MS spectrometer, both full scan and multiple reaction monitoring (MRM) data were acquired in the same run. By using this system, both qualitative analysis of untargeted hydrocarbons mixture (crude oil) and qualitative analysis of biomarker compounds, present in low amount and often hindered under the bulk of the sample (i.e. adamantanes, diamantanes, steranes and hopanes), were performed simultaneously. The bioremediation capability of biostimulated bacteria was evaluated at four (T 4 ), eight (T 8 ) and fourteen (T 14 ) days. Progressive degradation of linear, branched, and aromatic hydrocarbons, adamantanes, and diamantanes has been showed, whereas, results underline the lack of any kind of activity against steranes, and hopanes. Copyright © 2018 Elsevier B.V. All rights reserved.
Prieto-Blanco, M C; Alpendurada, M F; López-Mahía, P; Muniategui-Lorenzo, S; Prada-Rodríguez, D; Machado, S; Gonçalves, C
2012-05-30
Haloacetic acids (HAAs) are organic pollutants originated from the drinking water disinfection process, which ought to be controlled and minimized. In this work a method for monitoring haloacetic acids (HAAs) in water samples is proposed, which can be used in quality control laboratories using the techniques most frequently available. Among its main advantages we may highlight its automated character, including minimal steps of sample preparation, and above all, its improved selectivity and sensitivity in the analysis of real samples. Five haloacetic acids (HAA5) were analyzed using solid-phase extraction (SPE) combined with ion-pair liquid chromatography and tandem mass spectrometry. For the optimization of the chromatographic separation, two amines (triethylamine, TEA and dibutylamine, DBA) as ion pair reagents were compared, and a better selectivity and sensitivity was obtained using DBA, especially for monohaloacetic acids. SPE conditions were optimized using different polymeric adsorbents. The electrospray source parameters were studied for maximum precursor ion accumulation, while the collision cell energy of the triple quadrupole mass spectrometer was adjusted for optimum fragmentation. Precursor ions detected were deprotonated, dimeric and decarboxylated ions. The major product ions formed were: ionized halogen atom (chloride and bromide) and decarboxylated ions. After enrichment of the HAAs in Lichrolut EN adsorbent, the limits of detection obtained by LC-MS/MS analysis (between 0.04 and 0.3 ng mL(-1)) were comparable to those obtained by GC-MS after derivatization. Linearity with good correlation coefficients was obtained over two orders of magnitude irrespective of the compound. Adequate recoveries were achieved (60-102%), and the repeatability and intermediate precision were in the range of 2.4-6.6% and 3.8-14.8%, respectively. In order to demonstrate the usefulness of the method for routine HAAs monitoring, different types of water samples were analyzed. In swimming pool water samples the ∑HAAs were determined between 76 and 154 ng mL(-1). Copyright © 2012 Elsevier B.V. All rights reserved.
Romański, Michał; Teżyk, Artur; Zaba, Czesław; Główka, Franciszek K
2014-09-01
For the first time a high performance liquid chromatography method with tandem mass spectrometry detection (HPLC-MS/MS) was developed for simultaneous determination of a pro-drug treosulfan (TREO) and its active monoepoxide (S,S-EBDM) in biological matrices. Small volumes of rat plasma (50 μL) and the brain homogenate supernatant (100 μL), equivalent to 0.02 g of brain tissue, were required for the analysis. Protein-free TREO, S,S-EBDM and acetaminophen, internal standard (IS), were isolated from the samples by ultrafiltration. Complete resolution of the analytes and the IS was accomplished on Zorbax Eclipse column using an isocratic elution with a mobile phase composed of ammonium formate - formic acid buffer pH 4.0 and acetonitrile. Detection was performed on a triple-quadrupole MS via multiple-reaction-monitoring following electrospray ionization. The developed method was fully validated according to the current guidelines of the European Medicines Agency. Calibration curves were linear in ranges: TREO 0.2-5720 μM and S,S-EBDM 0.9-175 μM for plasma, and TREO 0.2-29 μM and S,S-EBDM 0.4-44 μM for the brain homogenate supernatant. The limits of quantitation of TREO and S,S-EBDM in the studied matrices were much lower in comparison to the previously used bioanalytical methods. The HPLC-MS/MS method was adequately precise (coefficient of variation≤12.2%), accurate (relative error≤8.6%), and provided no carry-over, acceptable matrix effect as well as dilution integrity. The analytes were stable in acidified plasma and the brain homogenate supernatant samples for 4 h at room temperature, for 4 months at-80°C as well as within two cycles of freezing and thawing, and demonstrated 18-24h autosampler stability. The validated method enabled determination of low concentrations of TREO and S,S-EBDM in incurred brain samples of the rats treated with TREO, which constitutes a novel bioanalytical application. Copyright © 2014 Elsevier B.V. All rights reserved.
Zhu, Jianwei; Xue, Bingyang; Ma, Bo; Zhang, Qi; Liu, Ming; Liu, Lei; Yao, Di; Qi, Huanhuan; Wang, Yonglu; Ying, Hanjie; Wu, Zimei
2015-07-01
A selective and sensitive high-performance liquid chromatography-electro-spray ionization tandem mass spectrometry (LC-ESI-MS/MS) method was developed for the simultaneous quantitative determination of Picroside-I, II, and III in rat plasma and tissue homogenate to aid the pre-clinical studies. The chromatographic separation was performed on a Hypersil GOLD AQ C18 column using a gradient elution program with a mobile phase consisting of 2mM ammonium acetate and acetonitrile. The detection was achieved using a triple quadrupole tandem MS in negative ionization multiple reaction monitoring (MRM) mode. One-step protein precipitation was selected for plasma and tissue sample preparation while liquid-liquid extraction failed to achieve satisfactory recoveries. The calibration curves of all three analytes in either plasma or tissue homogenate showed good linearity over the concentration range of 0.5-500ng/mL with a limit of quantitation at 0.5ng/mL. Both the intra- and inter-day accuracy and precision were within ±10%. The extraction recoveries were >70%, and the relative matrix effect ranged from 80.4% to 107.4% in all the biological samples. All the analytes were stable in matrices for at least 24h at room temperature, or 21 days in frozen. Three freeze/thaw cycles did not cause degradation. The method was successfully applied for quantification of the three iridoid glycosides in the collected plasma and various tissues following intravenous administration in rats. Picroside-I, II, and III were all eliminated rapidly with large volume of distribution. Among the three glycosides, Picroside-II showed the highest liver uptake, and only Picroside-I and II were found to get across the blood brain barrier (BBB). These results were consistent with their hepatoprotective or neuroprotective effects reported clinically. With the aid of the efficient and reliable simultaneous LC-ESI-MS/MS assay this pharmacokinetic study provided insights into their therapeutic targets of these three iridoid glycosides as well as valuable experimental basis for an expansion of their clinical indications. Copyright © 2015 Elsevier B.V. All rights reserved.
Ma, Bo; Zhang, Qi; Liu, Yinhui; Li, Jing; Xu, Qiuyu; Li, Xiaotian; Yang, Xiaojing; Yao, Di; Sun, Jingjing; Cui, Guangbo; Ying, Hanjie
2013-02-15
Eleutheroside B and Eleutheroside E, two kinds of the major bioactive saponins of Eleutherococcus senticosus, play a pivotal role in biologic activity. In this study, a specific and sensitive high performance liquid chromatography-electrospray ionization-tandem mass spectrometry method (HPLC-MS/MS) was developed and validated for simultaneous determination of Eleutheroside B and Eleutheroside E in rat plasma. The analytes were extracted from rat plasma via a simple protein precipitation procedure with methanol and polygonin was used as internal standard. Chromatographic separation was achieved on a C18 column using a gradient elution program with acetonitrile and water containing 0.1% ammonium hydroxide solution as the mobile phase, with a flow rate of 0.2mL/min. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reactions monitoring (MRM) mode in a negative ion mode via electrospray ionization (ESI). The transition monitored were m/z 371 [M-H](-)→209 for Eleutheroside B, m/z 741[M-H](-)→579 for Eleutheroside E and m/z 389[M-H](-)→277 for internal standard. Linear calibration curves were obtained in the concentration range of 1-2000ng/mL for both (Eleutheroside B and Eleutheroside E), with a lower limit of quantification of 1ng/mL. Extraction recovery was over 80% in plasma. The intra- and inter-day precision (RSD) values were below 12% and accuracy (RE) was -2.80 to 5.70% at three QC levels for both. The assay was successfully applied to study pharmacokinetics behavior in rats after oral and intravenous administration of the single substances (Eleutheroside B and Eleutheroside E). And further research was performed by comparing the difference in pharmacokinetic behavior between the single substances and an aqueous extract of E. senticosus after oral administration. Significant difference in pharmacokinetic characteristics between the single substances and an aqueous extract was found in rat, which would be beneficial for the pre-clinical research and clinical use of E. senticosus. Copyright © 2013. Published by Elsevier B.V.
Zhao, Pengfei; Deng, Miaoduo; Huang, Peiting; Yu, Jia; Guo, Xingjie; Zhao, Longshan
2016-09-01
This report describes, for the first time, the simultaneous enantioselective determination of proton-pump inhibitors (PPIs-omeprazole, lansoprazole, pantoprazole, and rabeprazole) in environmental water matrices based on solid-phase extraction combined with dispersive liquid-liquid microextraction (SPE-DLLME) and chiral liquid chromatography-tandem mass spectrometry. The optimized results of SPE-DLLME were obtained with PEP-2 column using methanol-acetonitrile (1/1, v/v) as elution solvent, dichloroethane, and acetonitrile as extractant and disperser solvent, respectively. The separation and determination were performed using reversed-phase chromatography on a cellulose chiral stationary phase, a Chiralpak IC (250 mm × 4.6 mm, 5 μm) column, under isocratic conditions at 0.6 mL min(-1) flow rate. The analytes were detected in multiple reaction monitoring (MRM) mode by triple quadrupole mass spectrometry. Isotopically labeled internal standards were used to compensate matrix interferences. The method provided enrichment factors of around 500. Under optimal conditions, the mean recoveries for all eight enantiomers from the water samples were 89.3-107.3 % with 0.9-10.3 % intra-day RSD and 2.3-8.1 % inter-day RSD at 20 and 100 ng L(-1) levels. Correlation coefficients (r (2)) ≥ 0.999 were achieved for all enantiomers within the range of 2-500 μg L(-1). The method detection and quantification limits were at very low levels, within the range of 0.67-2.29 ng L(-1) and 2.54-8.68 ng L(-1), respectively. This method was successfully applied to the determination of the concentrations and enantiomeric fractions of the targeted analytes in wastewater and river water, making it applicable to the assessment of the enantiomeric fate of PPIs in the environment. Graphical Abstract Simultaneous enantioselective determination of representative proton-pump inhibitors in water samples.
Shi, Aixin; Hu, Xin; Li, Kexin; Li, Jian; Han, Liping; Wan, Huayin; Li, Rubing
2012-11-01
Piperphentonamine hydrochloride (PPTA) is a new calcium sensitizer. A liquid chromatography-tandem mass spectrometry (LC/MS/MS) method for determination of piperphentonamine and its metabolites M1 and M6 was developed for the first time and applied to a pharmacokinetics study. Protein precipitation was used for pre-treatment of plasma samples, and solid phase extraction method was used for pre-treatment of urine samples. The chromatographic separation was achieved on a C(18) column using gradient elution in this study: A: 1% acetic acid aqueous solution, and B: acetonitrile. The whole analysis lasted for 10.5min and the gradient flow rate was 0.25mL/min constantly. The detection was performed of a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via a positive electrospray ionization source. The results were that the m/z ratios of monitored precursor ions and product ions of PPTA, M1 and M6 were 354.0→191.8, 356.0→148.7 and 358.0→148.7, respectively. From the standard curve, the concentration ranges of both PPTA and M1 in blood and urine samples were 0.1-500ng/mL and 0.1-200ng/mL, respectively; the concentration ranges of M6 in blood sample and urine sample were 0.2-500ng/mL and 0.2-200ng/mL, respectively; and the correlation coefficient of standard curve was r>0.99. A total of 31 healthy Chinese subjects participated in the pharmacokinetic study of single bolus intravenous injection of piperphentonamine hydrochloride. They were divided into three dosage groups and given 0.2, 0.4 and 0.6mg/kg of PPTA. After drug administration, concentrations of PPTA, M1 and M6 in human plasma and urine samples were determined to evaluation the pharmacokinetic characteristics of PPTA and its metabolites M1 and M6. Copyright © 2012 Elsevier B.V. All rights reserved.
Svanström, Camilla; Hansson, Gunnar P; Svensson, Leif D; Sennbro, Carl Johan
2012-01-25
The metabolic conversion of midazolam (MDZ) to its main metabolite 1'-hydroxy-midazolam (1-OH-MDZ) can be used as a probe drug for cytochrome P450 3A (CYP3A) activity. A sensitive method for the simultaneous determination of MDZ and its metabolite 1-OH-MDZ in human plasma using supported liquid extraction (SLE) in combination with liquid chromatography-tandem mass spectrometry (LC-MS/MS) detection was developed and validated. Plasma samples (100 μL) were diluted with 0.5M NH(3) (aq) containing deuterated internal standards. The samples were extracted with ethyl acetate on a 96-well SLE-plate. Separation was performed on a Symmetry Shield RP18 column using an acidic gradient running from 2% to 95% methanol in 3 min. Detection was performed using a triple quadrupole mass spectrometer running in positive electrospray selected reaction monitoring (SRM) mode. The validated dynamic range was 0.2-100 nmol/L for both analytes. In the concentration range 0.6-75 nmol/L the extraction recoveries were in the ranges 91.2-98.6% and 94.5-98.3% for MDZ and 1-OH-MDZ, respectively. Matrix effects were more pronounced for MDZ than for 1-OH-MDZ but the response was still 75.4% or higher compared to a reference. The overall repeatability was within 2.2-7.6% for both analytes, the overall reproducibility was within 3.1-10.2% for both analytes and the overall accuracy bias was within -1.1 to 7.5% for both analytes. The method was successfully applied to determine the plasma concentrations of MDZ and 1-OH-MDZ in 14 healthy volunteers up to 24h after administration of a single oral dose of 2mg MDZ. The SLE technology was found to be convenient and suitable for sample preparation, and the developed method was found to be rapid, selective and reproducible for the simultaneous determination of MDZ and 1-OH-MDZ in human plasma. Copyright © 2011 Elsevier B.V. All rights reserved.
Hu, Lei; Lv, Zhenhua; Li, Gao; Xu, Xiaolong; Zhang, Chenghao; Cao, Peng; Huang, Jiangeng; Si, Luqin
2015-06-01
TJ0711 (1-[4-(2-methoxyethyl)phenoxy]-3-[2-(2-methoxyphenoxy)ethylamino]-2-propanol) is a novel β-adrenoreceptor blocker with vasodilating activity. The aim of this study was to investigate the in vitro metabolic properties of TJ0711 from both qualitative and quantitative aspects using mouse, rat, dog, and human liver microsomes as well as rat hepatocytes. Two modern liquid chromatography with tandem mass spectrometry systems, ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry and ultra fast liquid chromatography with quadrupole linear ion trap mass spectrometry, were utilized for the analysis. To better characterize the metabolic pathways of TJ0711, two major metabolites were incubated under the same conditions as that for TJ0711. TJ0711 was extensively metabolized in vitro, and a total of 34 metabolites, including 19 phase I and 15 phase II metabolites, were identified. Similar metabolite profiles were observed among species, and demethylation, hydroxylation, carboxylic acid formation, and glucuronidation were proposed as the major metabolic routes. Significant interspecies differences were observed in the metabolic stability studies of TJ0711. Furthermore, gender differences were significant in mice, rats, and dogs, but were negligible in humans. The valuable information provided in this work will be useful in planning and interpreting further pharmacokinetic, in vivo metabolism and toxicological studies of this novel β-blocker. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Gaucher, Sara P.; Morrow, Jeffrey A.; Faulon, Jean-Loup M.
2007-09-14
Observed peptide gas-phase fragmentation patterns are a complex function of many variables. In order to systematically probe this phenomenon, an array of 40 peptides was synthesized for study. The array of sequences was designed to hold certain variables (peptide length) constant and randomize or balance others (peptide amino acid distribution and position). A high-quality tandem mass spectrometry (MS/MS) data set was acquired for each peptide for all observed charge states on multiple MS instruments, quadrupole-time-of-flight and quadrupole ion trap. The data were analyzed as a function of total charge state and number of mobile protons. Previously known dissociation trends weremore » observed, validating our approach. In addition, the general influence of basic amino acids on dissociation could be determined because, in contrast to the more widely studied tryptic peptides, the amino acids H, K, and R were positionally distributed. Interestingly, our results suggest that cleavage at all basic amino acids is suppressed when a mobile proton is available. Cleavage at H becomes favored only under conditions where a partially mobile proton is present, a caveat to the previously reported trend of enhanced cleavage at H. In conclusion, all acquired data were used as a benchmark to determine how well these sequences would have been identified in a database search using a common algorithm, Mascot.« less
Li, Kun-Yan; Zhou, Yan-Gang; Ren, Hua-Yi; Wang, Feng; Zhang, Bi-Kui; Li, Huan-De
2007-05-01
The ultra-performance liquid chromatography-electrospray tandem mass spectrometry (UPLC-ESI-MS/MS) method has been developed to perform the determination of quetiapine, perospirone, aripiprazole and quetiapine sulfoxide in in vitro samples in less than 3 min. The UPLC separation was carried out using an Acquity UPLC BEH C18 column (100 mm x 2.1mm i.d., 1.7 microm particle size) that provided high efficiency and resolution in combination with high linear velocities. The UPLC system was coupled to a Waters Micromass Quattro Premier XE tandem quadrupole mass spectrometer. This system permits high-speed data acquisition without peak intensity degradation, and produces sharp and narrow chromatographic peaks (w(h) about 2.5s) of compounds. The determination was performed in multiple reaction monitoring (MRM) mode. The quantification parameters of the developed method were established, obtaining instrumental LODs lower than 0.005 microg/l and a repeatability at a low concentration level lower than 10% CV (n=10). Finally, the method was successfully applied to the analysis of atypical antipsychotics and some metabolites in in vitro samples.
Shah, Priyanka A; Shah, Jaivik V; Sanyal, Mallika; Shrivastav, Pranav S
2017-03-01
A specific and rapid liquid chromatography-tandem mass spectrometry method is proposed for the simultaneous determination of metformin (MET), saxagliptin (SAXA) and its active metabolite, 5-hydroxy saxagliptin (5-OH SAXA) in human plasma. Sample preparation was accomplished from 50 μL plasma sample by solid-phase extraction using sodium dodecyl sulfate as an ion-pair reagent. Reversed-phase chromatographic resolution of analytes was possible within 3.5 min on ACE 5CN (150 × 4.6 mm, 5 μm) column using acetonitrile and10.0 mm ammonium formate buffer, pH 5.0 (80:20, v/v) as the mobile phase. Triple quadrupole mass spectrometric detection was performed using electrospray ionization in the positive ionization mode. The calibration curves showed good linearity (r 2 ≥ 0.9992) over the established concentration range with limit of quantification of 1.50, 0.10 and 0.20 ng/mL for MET, SAXA and 5-OH SAXA respectively. The extraction recoveries obtained from spiked plasma samples were highly consistent for MET (75.12-77.84%), SAXA (85.90-87.84%) and 5-OH SAXA (80.32-82.69%) across quality controls. The validated method was successfully applied to a bioequivalence study with a fixed-dose formulation consisting of 5 mg SAXA and 500 mg MET in 18 healthy subjects. The reproducibility of the assay was demonstrated by reanalysis of 87 incurred samples. Copyright © 2016 John Wiley & Sons, Ltd.
Asimakopoulos, Alexandros G; Kannan, Pranav; Higgins, Sean; Kannan, Kurunthachalam
2017-10-01
A liquid chromatography-triple quadrupole-tandem mass spectrometry (LC-qQq-MS/MS) method was developed for simultaneous determination of 89 legal neuropsychiatric pharmaceuticals and illicit drugs (both parent compounds and metabolites) and other micropollutants in unfiltered wastewater and freshwater. The target chemicals fall under the classes of amphetamine-type stimulants, cocaine compounds, opiates and opioids, benzodiazepines, lysergic compounds, antipsychotics, anesthetics, antiepileptics, antidepressants, sympathomimetics, cannabinoids, blood thinners, antihistamines, β-blockers, caffeine derivatives, nicotine derivatives, z-drugs, new designer drugs, and Alzheimer medications. The sample preparation procedure was designed for unfiltered wastewater and freshwater without the need to separate the particulate matter (if any) from the aqueous phase prior to extraction. Samples were pre-concentrated by rotary evaporation in the presence of a solvent. Method precision (absolute values; N = 6 replicate analyses at the fortification level of 50 ng, k = 6 days) for 87 out of 89 target analytes ranged from 2.8 to 34% (RSD %). The limits of detection ranged from 0.11 to 202 ng L -1 , and the matrix effects ranged from +16 to -84%. A total of 10 samples, 8 wastewater, 1 drinking water, and 1 lake water, were collected from New York State, USA, and were analyzed for the target compounds to demonstrate the applicability of the developed method. This is the first study to report the analysis of multiple classes of pharmaceuticals, illicit drugs, and other micropollutants in unfiltered wastewater. Graphical abstract Analysis of 89 micropollutants in unfiltered wastewater by LC-MS/MS.
Liu, Qing; Farley, Katherine L; Johnson, Amy J; Muthusamy, Natarajan; Hofmeister, Craig C; Blum, Kristie A; Schaaf, Larry J; Grever, Michael R; Byrd, John C; Dalton, James T; Phelps, Mitch A
2008-10-01
Lenalidomide, an immunomodulatory agent, and flavopiridol, a broad cyclin-dependent kinase inhibitor, are active therapies for clinical use in genomic high-risk chronic lymphocytic leukemia. A high-performance liquid chromatographic assay with tandem mass spectrometric detection has been developed to simultaneously quantify lenalidomide and flavopiridol in human and mouse plasma to facilitate their combined clinical development. Samples were prepared by liquid-liquid extraction with acetonitrile (ACN)-containing internal standard, genistein, followed by evaporation of solvent and reconstitution in 95/5 H2O/ACN. Lenalidomide and internal standard were separated by reversed-phase liquid chromatography on a C-18 column using a gradient of H2O and ACN, each with 0.1% formic acid. Atmospheric pressure chemical ionization in positive ion mode with single reaction monitoring on a triple quadrupole mass spectrometer was applied to detect transitions of lenalidomide (260.06 > 149.10) and flavopiridol (402.09 > 341.02). Lower limits of quantification of lenalidomide and flavopiridol were 1 and 0.3 nM, respectively. Recoveries of lenalidomide and flavopiridol from human plasma ranged from 99% to 116% throughout their linear ranges. Within- and between-run precision and accuracy of replicate samples were all less than 15%. This is the most sensitive analytical method reported to date for both lenalidomide and flavopiridol. This sensitivity will enable late terminal phase concentration measurements and accurate pharmacokinetic parameter estimation in a planned clinical trial with lenalidomide and flavopiridol in patients with chronic lymphocytic leukemia.
Ran-Ressler, Rinat R; Lawrence, Peter; Brenna, J Thomas
2012-01-01
Saturated branched chain fatty acids (BCFA) are present as complex mixtures in numerous biological samples. The traditional method for structure elucidation, electron ionization (EI) mass spectrometry, sometimes does not unambiguously enable assignment of branching in isomeric BCFA. Zirrolli and Murphy (Zirrolli , J. A. , and R. A. Murphy. 1993. Low-energy tandem mass spectrometry of the molecular ion derived from fatty acid methyl esters: a novel method for analysis of branched-chain fatty acids. J. Am. Soc. Mass Spectrom. 4: 223-229.) showed that the molecular ions of four BCFA methyl ester (BCFAME) yield highly characteristic fragments upon collisional dissociation using a triple quadrupole instrument. Here, we confirm and extend these results by analysis using a tabletop 3-D ion trap for activated molecular ion EI-MS/MS to 30 BCFAME. iso-BCFAME produces a prominent ion (30-100% of base peak) for [M-43] (M-C₃H₇), corresponding to the terminal isopropyl moiety in the original iso-BCFAME. Anteiso-FAME yield prominent ions (20-100% of base peak) corresponding to losses on both side of the methyl branch, [M-29] and [M-57], and tend to produce more prominent m/z 115 peaks corresponding to a cyclization product around the ester. Dimethyl and tetramethyl FAME, with branches separated by at least one methylene group, yield fragment on both sides of the sites of methyl branches that are more than 6 C away from the carboxyl carbon. EI-MS/MS yields uniquely specific ions that enable highly confident structural identification and quantification of BCFAME.
Ran-Ressler, Rinat R.; Lawrence, Peter; Brenna, J. Thomas
2012-01-01
Saturated branched chain fatty acids (BCFA) are present as complex mixtures in numerous biological samples. The traditional method for structure elucidation, electron ionization (EI) mass spectrometry, sometimes does not unambiguously enable assignment of branching in isomeric BCFA. Zirrolli and Murphy (Zirrolli , J. A. , and R. A. Murphy. 1993. Low-energy tandem mass spectrometry of the molecular ion derived from fatty acid methyl esters: a novel method for analysis of branched-chain fatty acids. J. Am. Soc. Mass Spectrom. 4: 223–229.) showed that the molecular ions of four BCFA methyl ester (BCFAME) yield highly characteristic fragments upon collisional dissociation using a triple quadrupole instrument. Here, we confirm and extend these results by analysis using a tabletop 3-D ion trap for activated molecular ion EI-MS/MS to 30 BCFAME. iso-BCFAME produces a prominent ion (30-100% of base peak) for [M-43] (M-C3H7), corresponding to the terminal isopropyl moiety in the original iso-BCFAME. Anteiso-FAME yield prominent ions (20-100% of base peak) corresponding to losses on both side of the methyl branch, [M-29] and [M-57], and tend to produce more prominent m/z 115 peaks corresponding to a cyclization product around the ester. Dimethyl and tetramethyl FAME, with branches separated by at least one methylene group, yield fragment on both sides of the sites of methyl branches that are more than 6 C away from the carboxyl carbon. EI-MS/MS yields uniquely specific ions that enable highly confident structural identification and quantification of BCFAME. PMID:22021637
Thevis, Mario; Beuck, Simon; Thomas, Andreas; Kortner, Birthe; Kohler, Maxie; Rodchenkov, Grigory; Schänzer, Wilhelm
2009-04-01
An important aspect of preventive doping research is the rapid implementation of tests for emerging drugs with potential for misuse into routine doping control assays. New therapeutics of different classes such as PPARdelta-agonists (e.g. GW501516), ryanodine-calstabin-complex stabilizers (e.g. S-107 and JTV-519), and selective androgen receptor modulators (SARMs, e.g. S-40503) are currently used for the treatment of particular medical conditions such as metabolic syndrome, cardiac arrhythmia, debilitating diseases and osteoporosis, respectively. Due to their being at an early stage of clinical trials and the limited availability of data on the metabolism and possible renal elimination of the active drugs, the development of protocols for doping control analyses of plasma specimens could be an option for the detection of the circulating agents. The mass spectrometric fragmentation of four emerging drug candidates (GW501516, S-107, JTV-519, and S-40503) was elucidated by positive electrospray ionization and collision-induced dissociation using a high resolution/high accuracy mass spectrometer. A screening and confirmation procedure was established based on liquid chromatography/tandem mass spectrometry requiring a volume of 100 microL of plasma. Proteins were precipitated using acetonitrile, the specimens were centrifuged and the supernatant analyzed using a triple-quadrupole mass spectrometer employing multiple reaction monitoring of diagnostic ion transitions. The method was validated with regard to specificity, limits of detection (0.4-8.3 ng/mL), recoveries (72-98%), intraday and interday precisions (12-21%), and ion suppression/enhancement effects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Page, Jason S.; Kelly, Ryan T.; Camp, David G.
2008-09-01
Methods. To improve the detection of low abundance protein candidate biomarker discovery and validation, particularly in complex biological fluids such as blood plasma, increased sensitivity is desired using mass spectrometry (MS)-based instrumentation. A key current limitation on the sensitivity of electrospray ionization (ESI) MS is due to the fact that many sample molecules in solution are never ionized, and the vast majority of the ions that are created are lost during transmission from atmospheric pressure to the low pressure region of the mass analyzer. Two key technologies, multi-nanoelectrospray emitters and the electrodynamic ion funnel have recently been developed and refinedmore » at Pacific Northwest National Laboratory (PNNL) to greatly improve the ionization and transmission efficiency of ESI MS based analyses. Multi-emitter based ESI enables the flow from a single source (typically a liquid chromatography [LC] column) to be divided among an array of emitters (Figure 1). The flow rate delivered to each emitter is thus reduced, allowing the well-documented benefits of nanoelectrospray 1 for both sensitivity and quantitation to be realized for higher flow rate separations. To complement the increased ionization efficiency afforded by multi-ESI, tandem electrodynamic ion funnels have also been developed at PNNL, and shown to greatly improve ion transmission efficiency in the ion source interface.2, 3 These technologies have been integrated into a triple quadrupole mass spectrometer for multiple reaction monitoring (MRM) of probable biomarker candidates in blood plasma and show promise for the identification of new species even at low level concentrations.« less
He, Gaoli; Guo, Beining; Yu, Jicheng; Zhang, Jing; Wu, Xiaojie; Cao, Guoying; Shi, Yaoguo; Tsai, Cheng-Yuan
2015-05-01
Three methods were developed and validated for determination of nemonoxacin in human feces and its major metabolite, nemonoxacin acyl-β- d-glucuronide, in human urine and feces. Nemonoxacin was extracted by liquid-liquid extraction in feces homogenate samples and nemonoxacin acyl-β- d-glucuronide by a solid-phase extraction procedure for pretreatment of both urine and feces homogenate sample. Separation was performed on a C18 reversed-phase column under isocratic elution with the mobile phase consisting of acetonitrile and 0.1% formic acid. Both analytes were determined by liquid chromatography-tandem mass spectrometry with positive electrospray ionization in selected reaction monitoring mode and gatifloxacin as the internal standard. The lower limit of quantitation (LLOQ) of nemonoxacin in feces was 0.12 µg/g and the calibration curve was linear in the concentration range of 0.12-48.00 µg/g. The LLOQ of the metabolite was 0.0010 µg/mL and 0.03 µg/g in urine and feces matrices, while the linear range was 0.0010-0.2000 µg/mL and 0.03-3.00 µg/g, respectively. Validation included selectivity, accuracy, precision, linearity, recovery, matrix effect, carryover, dilution integrity and stability, indicating that the methods can quantify the corresponding analytes with excellent reliability. The validated methods were successfully applied to an absolute bioavailability clinical study of nemonoxacin malate capsule. Copyright © 2014 John Wiley & Sons, Ltd.
Shimizu, Yoshibumi; Ishikawa, Masaki; Gotoh, Mari; Fukasawa, Keiko; Yamamoto, Shinji; Iwasa, Kensuke; Yoshikawa, Keisuke; Murakami-Murofushi, Kimiko
2018-02-15
Cyclic phosphatidic acid (cPA), an analog of lysophosphatidic acid, is involved in the regulation of many cellular processes. A sensitive and specific method to quantify the molecular species of cPA is important for studying the physiological and pathophysiological roles of cPA. Here, we developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based quantification method for the simultaneous detection of cPA species having various fatty acids (16:0, 18:0, 18:1, and 18:2) as well as 2-carba-cPA, a chemically synthesized analog of cPA. Chromatography was performed using a reversed-phase C18 column. cPA species were detected using a triple quadrupole mass spectrometer. cPA 17:0 was used as an internal standard. Intra- and interday precision values (CV%) were within 10%. The linear range of detection for each cPA species was 0.01 μg/mL to 5 μg/mL, with correlation coefficients of 0.998 or higher. The developed method was applied to the quantification of cPA species in mouse plasma and organs. The concentrations of cPA 16:0, 18:0, and 18:1 were revealed to be significantly reduced in the brains of cuprizone-treated mice, a model of multiple sclerosis, compared with control mice. These findings could be important for understanding the roles of cPA in the neurodegenerative processes associated with multiple sclerosis. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Stress-induced changes of neurosteroid profiles in rat brain and plasma under immobilized condition.
Park, Myeong Hyeon; Rehman, Shaheed Ur; Kim, In Sook; Choi, Min Sun; Yoo, Hye Hyun
2017-05-10
In this study, various neurosteroids in brain and plasma were simultaneously determined using liquid chromatography-tandem mass spectrometry and their profile changes in a stress-induced rats were investigated. The investigated neurosteroids are as follows: progesterone (P4), 5α-dihydroprogesterone (5α-DHP), 5β-dihydroprogesterone, estrone, androstenedione (AE), cortisol, cortisone, corticosterone (CORT), dehydroepiandrosterone (DHEA), pregnanolone (3α,5β-THP), allopregnanolone (ALLO), 11-deoxycorticosterone (DOC), 11-deoxycortisol, pregnenolone (PREG), and 5α/5β-tetrahydrodeoxycorticosterone (5α/5β-THDOC). Brain and plasma samples were processed using solid-phase extraction with methanol and acetic acid (99:1), and derivatized with a hydroxylamine reagent. Separation was achieved within 13min at a flow rate of 0.4mL/min with a C18 column (3.0×50mm, 2.7μm). The triple quadrupole mass spectrometer was operated in the positive electrospray ionization mode. Using this method, the neurosteroid level variation was quantitated and investigated in the brain and plasma upon immobilization stress in rats. As a result, AE, CORT, DOC, P4, 5α-DHP, 5α/5β-THDOC, DHEA, 3α,5β-THP, ALLO, and PREG levels were significantly altered in both the brain and plasma samples when stress was induced. These findings demonstrated that stress leads to the alteration of the GABAergic neurosteroid profile. The present results will be helpful for furthering an understanding of the role of neurosteroids in stressed conditions. Copyright © 2017 Elsevier B.V. All rights reserved.
A rapid screen for four corticosteroids in equine synovial fluid.
Agrawal, Karan; Ebel, Joseph G; Bischoff, Karyn
2014-06-01
Most antidoping method development in the equine industry has been for plasma and urine, though there has been recent interest in the analysis of synovial fluid for evidence of doping by intra-articular corticosteroid injection. Published methods for corticosteroid analysis in synovial fluid are primarily singleplex methods, do not screen for all corticosteroids of interest and are not adequately sensitive. The purpose of this study is to develop a rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) screening method for the detection of four of the most common intra-articularly administered corticosteroids--betamethasone, methylprednisolone, methylprednisolone acetate and triamcinolone acetonide. Sample preparation consisted of protein precipitation followed by a basified liquid-liquid extraction. LC-MS-MS experiments consisted of a six-min isocratic separation using a Phenomenex Polar-RP stationary phase and a mobile phase consisting of 35% acetonitrile, 5 mM ammonium acetate and 0.1% formic acid in nanopure water. The detection system used was a triple quadrupole mass analyzer with thermospray ionization, and compounds were identified using selective reaction monitoring. The method was validated to the ISO/IEC 17025 standard, and real synovial fluid samples were analyzed to demonstrate the application of the method in an antidoping context. The method was highly selective for the four corticosteroids with limits of detection of 1-3 ng/mL. The extraction efficiency was 50-101%, and the matrix effects were 14-31%. These results indicate that the method is a rapid and sensitive screen for the four corticosteroids in equine synovial fluid, fit for purpose for equine antidoping assays.
Rodríguez-Gómez, R; Zafra-Gómez, A; Camino-Sánchez, F J; Ballesteros, O; Navalón, A
2014-07-04
In the present work, two specific, accurate and sensitive methods for the determination of endocrine disrupting chemicals (EDCs) in human breast milk are developed and validated. Bisphenol A and its main chlorinated derivatives, five benzophenone-UV filters and four parabens were selected as target analytes. The method involves a stir-bar sorptive extraction (SBSE) procedure followed by a solvent desorption prior to GC-MS/MS or UHPLC-MS/MS analysis. A derivatization step is also necessary when GC analysis is performed. The GC column used was a capillary HP-5MS with a run time of 26min. For UHPLC analysis, the stationary phase was a non-polar Acquity UPLC(®) BEH C18 column and the run time was 10min. In both cases, the analytes were detected and quantified using a triple quadrupole mass spectrometer (QqQ). Quality parameters such as linearity, accuracy (trueness and precision), sensitivity and selectivity were examined and yielded good results. The limits of quantification (LOQs) ranged from 0.3 to 5.0ngmL(-1) for GC and from 0.2 to 1.0ngmL(-1) for LC. The relative standard deviation (RSD) was lower than 15% and the recoveries ranged from 92 to 114% in all cases, being slightly unfavorable the results obtained with LC. The methods were satisfactorily applied for the determination of target compounds in human milk samples from 10 randomly selected women. Copyright © 2014 Elsevier B.V. All rights reserved.
Li, Ke; Buchinger, Tyler J.; Bussy, Ugo; Fissette, Skye D.; Johnson, Nicholas; Li, Weiming
2015-01-01
Many fishes are hypothesized to use bile acids (BAs) as chemical cues, yet quantification of BAs in biological samples and the required methods remain limited. Here, we present an UHPLC–MS/MS method for simultaneous, sensitive, and rapid quantification of 15 BAs, including free, taurine, and glycine conjugated BAs, and application of the method to fecal samples from lake charr (Salvelinus namaycush). The analytes were separated on a C18 column with acetonitrile–water (containing 7.5 mM ammonium acetate and 0.1% formic acid) as mobile phase at a flow rate of 0.25 mL/min for 12 min. BAs were monitored with a negative electrospray triple quadrupole mass spectrometer (Xevo TQ-S™). Calibration curves of 15 BAs were linear over the concentration range of 1.00–5,000 ng/mL. Validation revealed that the method was specific, accurate, and precise. The method was applied to quantitative analysis of feces extract of fry lake charr and the food they were eating. The concentrations of analytes CA, TCDCA, TCA, and CDCA were 242.3, 81.2, 60.7, and 36.2 ng/mg, respectively. However, other taurine conjugated BAs, TUDCA, TDCA, and THDCA, were not detected in feces of lake charr. Interestingly, TCA and TCDCA were detected at high concentrations in food pellets, at 71.9 and 38.2 ng/mg, respectively. Application of the method to feces samples from lake charr supported a role of BAs as chemical cues, and will enhance further investigation of BAs as chemical cues in other fish species.
Peer, Cody J; Spencer, Shawn D; VanDenBerg, Dustin A H; Pacanowski, Michael A; Horenstein, Richard B; Figg, William D
2012-01-01
A sensitive, selective, and rapid ultra-high performance liquid chromatography-tandem mass spectrometry (uHPLC-MS/MS) was developed for the simultaneous quantification of clopidogrel (Plavix(®)) and its derivatized active metabolite (CAMD) in human plasma. Derivatization of the active metabolite in blood with 2-bromo-3'-methoxy acetophenone (MPB) immediately after collection ensured metabolite stability during sample handling and storage. Following addition of ticlopidine as an internal standard and simple protein precipitation, the analytes were separated on a Waters Acquity UPLC™ sub-2 μm-C(18) column via gradient elution before detection on a triple-quadrupole MS with multiple-reaction-monitoring via electrospray ionization. The method was validated across the clinically relevant concentration range of 0.01-50 ng/mL for parent clopidogrel and 0.1-150 ng/mL (r(2)=0.99) for CAMD, with a fast run time of 1.5 min to support pharmacokinetic studies using 75, 150, or 300 mg oral doses of clopidogrel. The analytical method measured concentrations of clopidogrel and CAMD with accuracy (%DEV) <±12% and precision (%CV) of <±6%. The method was successfully applied to measure the plasma concentrations of clopidogrel and CAMD in three subjects administered single oral doses of 75, 150, and 300 mg clopidogrel. It was further demonstrated that the derivatizing agent (MPB) does not affect clopidogrel levels, thus from one aliquot of blood drawn clinically, this method can simultaneously quantify both clopidogrel and CAMD with sensitivity in the picogram per mL range. Published by Elsevier B.V.
Peer, Cody J.; Spencer, Shawn D.; VanDenBerg, Dustin A. H.; Pacanowski, Michael A.; Horenstein, Richard B.; Figg, William D.
2011-01-01
A sensitive, selective, and rapid ultra-high performance liquid chromatography-tandem mass spectrometry (uHPLC-MS/MS) was developed for the simultaneous quantification of clopidogrel (Plavix®) and its derivatized active metabolite (CAMD) in human plasma. Derivatization of the active metabolite in blood with 2-bromo-3’-methoxy acetophenone (MPB) immediately after collection ensured metabolite stability during sample handling and storage. Following addition of ticlopidine as an internal standard and simple protein precipitation, the analytes were separated on a Waters Acquity UPLC™ sub-2µm-C18 column via gradient elution before detection on a triple-quadrupole MS with multiple-reaction-monitoring via electrospray ionization. The method was validated across the clinically-relevant concentration range of 0.01–50 ng/mL for parent clopidogrel and 0.1–150 ng/mL (r2= 0.99) for CAMD, with a fast run time of 1.5 min to support pharmacokinetic studies using 75, 150, or 300 mg oral doses of clopidogrel. The analytical method measured concentrations of clopidogrel and CAMD with accuracy (%DEV) < ±12% and precision (%CV) of < ±6%. The method was successfully applied to measure the plasma concentrations of clopidogrel and CAMD in three subjects administered single oral doses of 75, 150, and 300 mg clopidogrel. It was further demonstrated that the derivatizing agent (MPB) does not affect clopidogrel levels, thus from one aliquot of blood drawn clinically, this method can simultaneously quantify both clopidogrel and CAMD with sensitivity in the picogram per mL range. PMID:22169056
Yao, Yuan; Shao, Yijun; Zhan, Ming; Zou, Xiaoli; Qu, Weidong; Zhou, Ying
2018-06-01
Bisphenol analogues, amphenicol antibiotics, and phthalate have widely aroused public concerns due to their adverse effects on human health. In this study, a rapid and sensitive method for determination of nine bisphenol analogues, three amphenicol antibiotics, and six phthalate metabolites in the urine based on ultra-high-performance liquid chromatography coupled with triple quadrupole tandem mass spectrometry was developed and validated. The sample pretreatment condition on the base of mixed-mode anion-exchange (Oasis MAX) SPE was optimized to separate bisphenol analogues and amphenicol antibiotics from phthalate metabolites: the former were detected with a mobile phase of 0.1% ammonium water solution/methanol containing 0.1% ammonium water solution in negative mode, whereas the latter were determined with a mobile phase of 0.1% acetic acid solution/acetonitrile containing 0.1% acetic acid in negative mode. The limits of detection were less than 0.26 ng/mL for bisphenol analogues, 0.12 ng/mL for amphenicol antibiotics, and 0.14 ng/mL for phathalate metabolites. The recoveries of all target analytes in three fortification levels ranged from 72.02 to 117.64% with the relative standard deviations of no larger than 14.51%. The matrix effect was adjusted by isotopically labeled internal standards. This proposed method was successfully applied to analyze 40 actual urines and 13 out of 18 studied compounds were detected. Graphical abstract Simultaneous determination of nine bisphenol analogues, three amphenicol antibiotics, and six phthalate metabolites in human urine samples.
He, Zeying; Wang, Yuehua; Wang, Lu; Peng, Yi; Wang, Wenwen; Liu, Xiaowei
2017-02-01
In this study, a simple and high-throughput method for determination of 255 pesticides in vegetable oils was developed based on QuEChERS sample preparation method combined with gas chromatography-triple quadrupole mass spectrometry. Different clean-up approaches were tested: A, 150 mg PSA + 150 mg C18; B, 250 mg PSA + 250 mg C18; C, 250 mg PSA + 250 mg C18 + 15 mg GCB; D, 250 mg PSA + 250 mg C18 + 50 mg GCB; and E, EMR-Lipid TM . Best clean-up capacity was observed for EMR clean-up. The extraction procedures and parameters, including extraction time, solvent/sample ratio, and buffer system, were also thoroughly investigated and optimized. The limits of quantification (LOQ) ranged between 5 and 50 μg kg -1 , and for the majority of the pesticides the LOQs were 5 μg kg -1 , which were below the regulatory MRLs. Most recoveries at seven spiking levels were in the range of 70-120 % with RSDs <20 % indicating satisfactory accuracy. The coefficient of determination (r 2 ) was >0.99 within the calibration linearity range of 2-500 μg L -1 for the majority of the pesticides. This method was proved to be simple, sensitive, and effective, which can be applied for large-scale pesticide screening and quantification in vegetable oils.
Peterson, Kari; Cole-Dai, Jihong; Brandis, Derek; Cox, Thomas; Splett, Scott
2015-10-01
An ion chromatography-electrospray ionization-tandem mass spectrometry (IC-ESI-MS/MS) method has been developed for rapid and accurate measurement of perchlorate in polar snow and ice core samples in which perchlorate concentrations are expected to be as low as 0.1 ng L(-1). Separation of perchlorate from major inorganic species in snow is achieved with an ion chromatography system interfaced to an AB SCIEX triple quadrupole mass spectrometer operating in multiple reaction monitoring mode. Under optimized conditions, the limit of detection and lower limit of quantification without pre-concentration have been determined to be 0.1 and 0.3 ng L(-1), respectively, with a linear dynamic range of 0.3-10.0 ng L(-1) in routine measurement. These represent improvements over previously reported methods using similar analytical techniques. The improved method allows fast, accurate, and reproducible perchlorate quantification down to the sub-ng L(-1) level and will facilitate perchlorate measurement in the study of natural perchlorate production with polar ice cores in which perchlorate concentrations are anticipated to vary in the low and sub-ng L(-1) range. Initial measurements of perchlorate in ice core samples from central Greenland show that typical perchlorate concentrations in snow dated prior to the Industrial Revolution are about 0.8 ng L(-1), while perchlorate concentrations are significantly higher in recent (post-1980) snow, suggesting that anthropogenic sources are a significant contributor to perchlorate in the current environment.
Idder, Salima; Ley, Laurent; Mazellier, Patrick; Budzinski, Hélène
2013-12-17
One of the current environmental issues concerns the presence and fate of pharmaceuticals in water bodies as these compounds may represent a potential environmental problem. The characterization of pharmaceutical contamination requires powerful analytical method able to quantify these pollutants at very low concentration (few ng L(-1)). In this work, a multi-residue analytical methodology (on-line solid phase extraction-liquid chromatography-triple quadrupole mass spectrometry using positive and negative electrospray ionization) has been developed and validated for 40 multi-class pharmaceuticals and metabolites for tap and surface waters. This on-line SPE method was very convenient and efficient compared to classical off-line SPE method because of its shorter total run time including sample preparation and smaller sample volume (1 mL vs up to 1 L). The optimized method included several therapeutic classes as lipid regulators, antibiotics, beta-blockers, non-steroidal anti-inflammatories, antineoplastic, etc., with various physicochemical properties. Quantification has been achieved with the internal standards. The limits of detection are between 0.7 and 15 ng L(-1) for drinking waters and 2-15 ng L(-1) for surface waters. The inter-day precision values are below 20% for each studied level. The improvement and strength of the analytical method has been verified along a monitoring of these 40 pharmaceuticals in Isle River, a French stream located in the South West of France. During this survey, 16 pharmaceutical compounds have been detected. Copyright © 2013 Elsevier B.V. All rights reserved.
Guo, Panpan; Dong, Lihua; Yan, Wenying; Wei, Jianceng; Wang, Chunying; Zhang, Zijian
2015-02-01
A sensitive and reproducible liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous determination of linarin, naringenin and formononetin in rat plasma after addition of sulfamethoxazole as the internal standard (IS). Separation was carried out on a Diamonsil C18 column (150 × 4.6 mm, 5 µm) with liner gradient elution using methanol (A) and 0.5‰ formic acid aqueous solution (B). Detection was performed on a triple-quadrupole linear ion trap mass spectrometer with the negative ion electrospray ionization in multiple-reaction monitoring (MRM) mode. The MRM transitions were m/z 591.2 → 283.2, 271.0 → 150.9, 266.9 → 252.0 and 252.0 → 155.9 for linarin, naringenin, formononetin and IS, respectively. All analytes showed good linearity within the concentration range (r > 0.9973). The lower limits of quantitation of linarin, naringenin and formononetin were 0.64, 1.07 and 1.04 ng/mL, respectively. Intra-day and inter-day precisions of the investigated components exhibited an RSD within 9.96%, and the accuracy (relative error) ranged from -11.25 to 9.38% at all quality control levels. The developed method was successfully applied to a pharmacokinetic study of linarin, naringenin and formononetin in rats after oral administration of Bushen Guchi Pill. Copyright © 2014 John Wiley & Sons, Ltd.
Development of a tandem-electrostatic-quadrupole accelerator facility for BNCT.
Kreiner, A J; Thatar Vento, V; Levinas, P; Bergueiro, J; Di Paolo, H; Burlon, A A; Kesque, J M; Valda, A A; Debray, M E; Somacal, H R; Minsky, D M; Estrada, L; Hazarabedian, A; Johann, F; Suarez Sandin, J C; Castell, W; Davidson, J; Davidson, M; Giboudot, Y; Repetto, M; Obligado, M; Nery, J P; Huck, H; Igarzabal, M; Fernandez Salares, A
2009-07-01
In this work we describe the present status of an ongoing project to develop a tandem-electrostatic-quadrupole (TESQ) accelerator facility for accelerator-based (AB) BNCT at the Atomic Energy Commission of Argentina in Buenos Aires. The project final goal is a machine capable of delivering 30 mA of 2.4 MeV protons to be used in conjunction with a neutron production target based on the (7)Li(p,n)(7)Be reaction slightly beyond its resonance at 2.25 MeV. These are the specifications needed to produce sufficiently intense and clean epithermal neutron beams, based on the (7)Li(p,n)(7)Be reaction, to perform BNCT treatment for deep-seated tumors in less than an hour. An electrostatic machine is the technologically simplest and cheapest solution for optimized AB-BNCT. The machine being designed and constructed is a folded TESQ with a high-voltage terminal at 1.2 MV intended to work in air. Such a machine is conceptually shown to be capable of transporting and accelerating a 30 mA proton beam to 2.4 MeV. The general geometric layout, its associated electrostatic fields, and the acceleration tube are simulated using a 3D finite element procedure. The design and construction of the ESQ modules is discussed and their electrostatic fields are investigated. Beam transport calculations through the accelerator are briefly mentioned. Likewise, work related to neutron production targets, strippers, beam shaping assembly and patient treatment room is briefly described.
Tong, Chaoying; Peng, Mijun; Tong, Runna; Ma, Ruyi; Guo, Keke; Shi, Shuyun
2018-01-19
Chemical profiling of natural products by high performance liquid chromatography (HPLC) was critical for understanding of their clinical bioactivities, and sample pretreatment steps have been considered as a bottleneck for analysis. Currently, concerted efforts have been made to develop sample pretreatment methods with high efficiency, low solvent and time consumptions. Here, a simple and efficient online extraction (OLE) strategy coupled with HPLC-diode array detector-quadrupole time-of-flight tandem mass spectrometry (HPLC-DAD-QTOF-MS/MS) was developed for rapid chemical profiling. For OLE strategy, guard column inserted with ground sample (2 mg) instead of sample loop was connected with manual injection valve, in which components were directly extracted and transferred to HPLC-DAD-QTOF-MS/MS system only by mobile phase without any extra time, solvent, instrument and operation. By comparison with offline heat-reflux extraction of Citrus paradisi cv. Changshanhuyu (Changshanhuyu) peel, OLE strategy presented higher extraction efficiency perhaps because of the high pressure and gradient elution mode. A total of twenty-two secondary metabolites were detected according to their retention times, UV spectra, exact mass, and fragmentation ions in MS/MS spectra, and nine of them were discovered in Changshanhuyu peel for the first time to our knowledge. It is concluded that the developed OLE-HPLC-DAD-QTOF-MS/MS system offers new perspectives for rapid chemical profiling of natural products. Copyright © 2017 Elsevier B.V. All rights reserved.
Tong, Runna; Peng, Mijun; Tong, Chaoying; Guo, Keke; Shi, Shuyun
2018-03-01
Chemical profiling of natural products by high performance liquid chromatography (HPLC) was critical for understanding of their clinical bioactivities, and sample pretreatment steps have been considered as a bottleneck for analysis. Currently, concerted efforts have been made to develop sample pretreatment methods with high efficiency, low solvent and time consumptions. Here, a simple and efficient online extraction (OLE) strategy coupled with HPLC-diode array detector-quadrupole time-of-flight tandem mass spectrometry (HPLC-DAD-QTOF-MS/MS) was developed for rapid chemical profiling. For OLE strategy, guard column inserted with ground sample (2 mg) instead of sample loop was connected with manual injection valve, in which components were directly extracted and transferred to HPLC-DAD-QTOF-MS/MS system only by mobile phase without any extra time, solvent, instrument and operation. By comparison with offline heat-reflux extraction for Fructus aurantii immaturus (Zhishi), OLE strategy presented higher extraction efficiency perhaps because of the high pressure and gradient elution mode. A total of eighteen flavonoids were detected according to their retention times, UV spectra, exact mass, and fragmentation ions in MS/MS spectra, and compound 9, natsudaidain-3-O-glucoside, was discovered in Zhishi for the first time. It is concluded that the developed OLE-HPLC-DAD-QTOF-MS/MS system offers new perspectives for rapid chemical profiling of natural products. Copyright © 2018. Published by Elsevier B.V.
Walorczyk, Stanisław; Drożdżyński, Dariusz; Kierzek, Roman
2015-01-01
A method was developed for pesticide analysis in samples of high chlorophyll content belonging to the group of minor crops. A new type of sorbent, known as ChloroFiltr, was employed for dispersive-solid phase extraction cleanup (dispersive-SPE) to reduce the unwanted matrix background prior to concurrent analysis by gas chromatography and ultra-performance liquid chromatography coupled to tandem quadrupole mass spectrometry (GC-MS/MS and UPLC-MS/MS). Validation experiments were carried out on green, unripe plants of lupin, white mustard and sorghum. The overall recoveries at the three spiking levels of 0.01, 0.05 and 0.5 mg kg(-1) fell in the range between 68 and 120% (98% on average) and 72-104% (93% on average) with relative standard deviation (RSD) values between 2 and 19% (7% on average) and 3-16% (6% on average) by GC-MS/MS and UPLC-MS/MS technique, respectively. Because of strong enhancement or suppression matrix effects (absolute values >20%) which were exhibited by about 80% of the pesticide and matrix combinations, acceptably accurate quantification was achieved by using matrix-matched standards. Up to now, the proposed method has been successfully used to study the dissipation patterns of pesticides after application on lupin, white mustard, soya bean, sunflower and field bean in experimental plot trials conducted in Poland. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
March, Raymond E.; Li, Hongxia; Belgacem, Omar; Papanastasiou, Dimitris
2007-04-01
Product ion mass spectra of a series of nine protonated flavonoids have been observed by electrospray ionization combined with quadrupole/time-of-flight (ESI QTOF), and matrix-assisted laser desorption ionization combined either with quadrupole ion trap (MALDI QIT) tandem mass spectrometry or time-of-flight tandem mass spectrometry (MALDI TOF ReTOF). The compounds examined are 3,6-, 3,2'-, and 3,3'-dihydoxyflavone, apigenin (5,7,4'-trihydroxyflavone), luteolin (5,7,3',4'-tetrahydroxyflavone), apigenin-7-O-glucoside, hesperidin (5,7,3'-trihydroxy-4'-methoxyflavanone), daidzen (7,4'-dihydroxyisoflavone), and rutin (quercitin-3-O-rutinoside) where quercitin is 3,5,7,3',4'-pentahydroxyflavone; sodiated rutin was examined also. The center-of-mass energies in ESI QTOF and MALDI QIT are similar (1-4 eV) and their product ion mass spectra are virtually identical. In the MALDI TOF ReTOF instrument, center-of-mass energies range from 126-309 eV for sodiated rutin to protonated dihydroxyflavones, respectively. Due to the high center-of-mass energies available with the MALDI TOF ReTOF instrument, some useful structural information may be obtained; however, with increasing precursor mass/charge ratio, product ion mass spectra become simplified so as to be of limited structural value. Electronic excitation of the protonated (and sodiated) species examined here offers an explanation for the very simple product ion mass spectra observed particularly for glycosylated flavonoids.
Li, Shuping; Liu, Wei; Teng, Liang; Cheng, Xuemei; Wang, Zhengtao; Wang, Changhong
2014-04-01
Harmane, a β-carboline alkaloid with a wide spectrum of pharmacological activities, is naturally present in the human diet, in numerous foodstuffs and in hallucinogenic plants such as Peganum harmala, Banisteriopsis caapi and Tribulus terrestris. However, the precise metabolic fate of harmane remains unknown. In order to know whether harmane is extensively metabolized, a rapid and sensitive method using ultra-performance liquid chromatography combined with electrospray ionization quadrupole time-of-flight tandem mass spectrometry (UPLC/ESI-QTOF-MS) was used to analyze the metabolic profile of harmane in vitro and in vivo in rats. A total of 21 metabolites were identified from the rat liver microsomes and rat liver S9 (9), rat urine (11), feces (16), bile (16), and plasma (10) after a single oral administration of harmane using MetaboLynx™ and MassFragment ™ software tools. It indicated that the biliary and faecal clearance were the major excretion routes for harmane as well as its metabolites. The specific CLogP values combined with different acidic and alkaline mobile phase were helpful and useful for distinguishing N-oxidation and monohydroxylation metabolites. The metabolic transformation pathways of harmane included monohydroxylation, dihydroxylation, N-oxidation, O-glucuronide conjugation, O-sulphate conjugation, and glutathione conjugation. In conclusion, this study showed an insight into the metabolism of harmane. Copyright © 2014 Elsevier B.V. All rights reserved.
Fang, Lian-xiang; Xiong, Ai-zhen; Wang, Rui; Ji, Shen; Yang, Li; Wang, Zheng-tao
2013-09-01
The objective of this study was to develop an effective strategy for screening and identifying mycotoxins in herbal medicine (HM). Here, Imperatae Rhizoma, a commonly used Chinese herb, was selected as a model HM. A crude drug contaminated with fungi was analyzed by comparing with uncontaminated ones. Ultra-performance LC coupled to tandem quadrupole TOF-MS (UPLC-Q-TOF-MS) with collision energy function was applied to analyze different samples from Imperatae Rhizoma. Then, MarkerLynx(TM) software was employed to screen the excess components in analytes, compared with control samples, and those selected markers were likely to be the metabolites of fungi. Furthermore, each of the accurate masses of the markers obtained from MarkerLynx(TM) was then searched in a mycotoxins/fungal metabolites database established in advance. The molecular formulas with relative mass error between the measured and theoretical mass within 5 ppm were chosen and then applied to MassFragment(TM) analysis for further confirmation of their structures. With the use of this approach, five mycotoxins that have never been reported in HM were identified in contaminated Imperatae Rhizoma. The results demonstrate the potential of UPLC-Q-TOF-MS coupled with the MarkerLynx(TM) software and MassFragment(TM) tool as an efficient and convenient method to screen and identify mycotoxins in herbal materials and aid in the quality control of HM. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Huang, Aihua; Xu, Hui; Zhan, Ruoting; Chen, Weiwen; Liu, Jiawei; Chi, Yuguang; Chen, Daidi; Ji, Xiaoyu; Luo, Chaoquan
2017-03-23
Skimmianine is a furoquinoline alkaloid present mainly in the Rutaceae family. It has been reported to have analgesic, antispastic, sedative, anti-inflammatory, and other pharmacologic activities. Despite its critical pharmacological function, its metabolite profiling is still unclear. In this study, the in vivo metabolite profiling of skimmianine in rats was investigated using ultra-performance liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry (UPLC/Q-TOF-MS). The metabolites were predicted using MetabolitePilot TM software. These predicted metabolites were further analyzed by MS² spectra, and compared with the detailed fragmentation pathway of the skimmianine standard and literature data. A total of 16 metabolites were identified for the first time in rat plasma, urine, and feces samples after oral administration of skimmianine. Skimmianine underwent extensive Phase I and Phase II metabolism in rats. The Phase I biotransformations of skimmianine consist of epoxidation of olefin on its furan ring (M1) followed by the hydrolysis of the epoxide ring (M4), hydroxylation (M2, M3), O -demethylation (M5-M7), didemethylation (M14-M16). The Phase II biotransformations include glucuronide conjugation (M8-M10) and sulfate conjugation (M11-M13). The epoxidation of 2,3-olefinic bond followed by the hydrolysis of the epoxide ring and O -demethylation were the major metabolic pathways of skimmianine. The results provide key information for understanding the biotransformation processes of skimmianine and the related furoquinoline alkaloids.
Wang, Zhenzhong; Geng, Jianliang; Dai, Yi; Xiao, Wei; Yao, Xinsheng
2015-01-01
The broad applications and mechanism explorations of traditional Chinese medicine prescriptions (TCMPs) require a clear understanding of TCMP chemical constituents. In the present study, we describe an efficient and universally applicable analytical approach based on ultra-performance liquid chromatography coupled to electrospray ionization tandem quadrupole time-of-flight mass spectrometry (UPLC-ESI-Q/TOF-MS) with the MSE (E denotes collision energy) data acquisition mode, which allowed the rapid separation and reliable determination of TCMP chemical constituents. By monitoring diagnostic ions in the high energy function of MSE, target peaks of analogous compounds in TCMPs could be rapidly screened and identified. “Re-Du-Ning” injection (RDN), a eutherapeutic traditional Chinese medicine injection (TCMI) that has been widely used to reduce fever caused by viral infections in clinical practice, was studied as an example. In total, 90 compounds, including five new iridoids and one new sesquiterpene, were identified or tentatively characterized by accurate mass measurements within 5 ppm error. This analysis was accompanied by MS fragmentation and reference standard comparison analyses. Furthermore, the herbal sources of these compounds were unambiguously confirmed by comparing the extracted ion chromatograms (EICs) of RDN and ingredient herbal extracts. Our work provides a certain foundation for further studies of RDN. Moreover, the analytical approach developed herein has proven to be generally applicable for profiling the chemical constituents in TCMPs and other complicated mixtures. PMID:25875968
Vikingsson, Svante; Gréen, Henrik; Brinkhagen, Linda; Mukhtar, Shahzabe; Josefsson, Martin
2016-09-01
Synthetic cannabinoids are a group of psychoactive drugs presently widespread among drug users in Europe. Analytical methods to measure these compounds in urine are in demand as urine is a preferred matrix for drug testing. For most synthetic cannabinoids, the parent compounds are rarely detected in urine. Therefore urinary metabolites are needed as markers of drug intake. AB-FUBINACA was one of the top three synthetic cannabinoids most frequently found in seizures and toxicological drug screening in Sweden (2013-2014). Drug abuse is also reported from several other countries such as the USA and Japan. In this study, 28 authentic case samples were used to identify urinary markers of AB-FUBINACA intake using liquid chromatography quadrupole tandem time of flight mass spectrometry and human liver microsomes. Three metabolites suitable as markers of drug intake were identified and at least two of them were detected in all but one case. In total, 15 urinary metabolites of AB-FUBINACA were reported, including hydrolxylations on the indazole ring and the amino-oxobutane moiety, dealkylations and hydrolysis of the primary amide. No modifications on the fluorobenzyl side-chain were observed. The parent compound was detected in 54% of the case samples. Also, after three hours of incubation with human liver microsomes, 77% of the signal from the parent compound remained. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Prastianto, R. W.; Dwipayana, K. H.; Syahroni, N.; Pumbarino, B.
2018-03-01
This paper examines the results of laboratory experiments to investigate the effect of interference of two tandem cylinders covered by triple helical rods with gap to the induced drag force. Two identical rigid models are horizontally positioned with roll support on both ends of each cylinder. Uniform air flow in subcritical regime that correspond to Reynolds number (Re) of 1.6 × 104 ∼ 6.5 × 104 perpendicularly flowed to the models in the wind tunnel with three variations of the distance between the cylinders which are 1.75D, 3D and 5D. At Re = 4.2 × 104 the results show that the maximum shielding effects occur in the rear cylinder at the distance of 1.75D so the drag coefficient (CD) is reduced to 93.6% compared to single cylinder case. This shielding effect will weaken with increasing the distance between the cylinder. In contrast, the fluid flow interference effect on the front cylinder increases due to increasing of spacing between the two cylinders and still occurred at that spacing of 5D until CD reduction reached 10% of the single cylinder case.
Model for threading dislocations in metamorphic tandem solar cells on GaAs (001) substrates
NASA Astrophysics Data System (ADS)
Song, Yifei; Kujofsa, Tedi; Ayers, John E.
2018-02-01
We present an approximate model for the threading dislocations in III-V heterostructures and have applied this model to study the defect behavior in metamorphic triple-junction solar cells. This model represents a new approach in which the coefficient for second-order threading dislocation annihilation and coalescence reactions is considered to be determined by the length of misfit dislocations, LMD, in the structure, and we therefore refer to it as the LMD model. On the basis of this model we have compared the average threading dislocation densities in the active layers of triple junction solar cells using linearly-graded buffers of varying thicknesses as well as S-graded (complementary error function) buffers with varying thicknesses and standard deviation parameters. We have shown that the threading dislocation densities in the active regions of metamorphic tandem solar cells depend not only on the thicknesses of the buffer layers but on their compositional grading profiles. The use of S-graded buffer layers instead of linear buffers resulted in lower threading dislocation densities. Moreover, the threading dislocation densities depended strongly on the standard deviation parameters used in the S-graded buffers, with smaller values providing lower threading dislocation densities.
Natić, Maja M; Dabić, Dragana Č; Papetti, Adele; Fotirić Akšić, Milica M; Ognjanov, Vladislav; Ljubojević, Mirjana; Tešić, Živoslav Lj
2015-03-15
In this study, the polyphenolic profile of 11 Morus alba fruits grown in the Vojvodina region was investigated. Ultra high performance liquid chromatography (UHPLC) coupled with Linear Trap Quadrupole and OrbiTrap mass analyzer, and UHPLC coupled with a diode array detector and a triple-quadrupole mass spectrometer were used for the identification and quantification of the polyphenols, respectively. A total of 14 hydroxycinnamic acid esters, 13 flavonol glycosides, and 14 anthocyanins were identified in the extracts with different distributions and contents according to the sampling. The total phenolic content ranged from 43.84 to 326.29 mg GAE/100g frozen fruit. The radical scavenging capacity (50.18-86.79%), metal chelating ability (0.21-8.15%), ferric ion reducing power (0.03-38.45 μM ascorbic acid) and superoxide anion radical scavenging activity (16.53-62.83%) were assessed. The findings indicated that mulberry polyphenolics may act as potent superoxide anion radical scavengers and reducing agents. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ultra-Thin, Triple-Bandgap GaInP/GaAs/GaInAs Monolithic Tandem Solar Cells
NASA Technical Reports Server (NTRS)
Wanlass, M. W.; Ahrenkiel, S. P.; Albin, D. S.; Carapella, J. J.; Duda, A.; Emery, K.; Geisz, J. F.; Jones, K.; Kurtz, Sarah; Moriarty, T.;
2007-01-01
The performance of state-of-the-art, series-connected, lattice-matched (LM), triple-junction (TJ), III-V tandem solar cells could be improved substantially (10-12%) by replacing the Ge bottom subcell with a subcell having a bandgap of approx.1 eV. For the last several years, research has been conducted by a number of organizations to develop approx.1-eV, LM GaInAsN to provide such a subcell, but, so far, the approach has proven unsuccessful. Thus, the need for a high-performance, monolithically integrable, 1-eV subcell for TJ tandems has remained. In this paper, we present a new TJ tandem cell design that addresses the above-mentioned problem. Our approach involves inverted epitaxial growth to allow the monolithic integration of a lattice-mismatched (LMM) approx.1- eV GaInAs/GaInP double-heterostructure (DH) bottom subcell with LM GaAs (middle) and GaInP (top) upper subcells. A transparent GaInP compositionally graded layer facilitates the integration of the LM and LMM components. Handle-mounted, ultra-thin device fabrication is a natural consequence of the inverted-structure approach, which results in a number of advantages, including robustness, potential low cost, improved thermal management, incorporation of back-surface reflectors, and possible reclamation/reuse of the parent crystalline substrate for further cost reduction. Our initial work has concerned GaInP/GaAs/GaInAs tandem cells grown on GaAs substrates. In this case, the 1- eV GaInAs experiences 2.2% compressive LMM with respect to the substrate. Specially designed GaInP graded layers are used to produce 1-eV subcells with performance parameters nearly equaling those of LM devices with the same bandgap (e.g., LM, 1-eV GaInAsP grown on InP). Previously, we reported preliminary ultra-thin tandem devices (0.237 cm2) with NREL-confirmed efficiencies of 31.3% (global spectrum, one sun) (1), 29.7% (AM0 spectrum, one sun) (2), and 37.9% (low-AOD direct spectrum, 10.1 suns) (3), all at 25 C. Here, we include recent results of testing similar devices under the concentrated AMO spectrum, and also present the first demonstration of a high-efficiency, ultra-thin GaInP/GaAs/GaInAs tandem cell processed on a flexible kapton handle.
Stingl, Nadja; Krischke, Markus; Fekete, Agnes; Mueller, Martin J
2013-01-01
Defense signaling compounds and phytohormones play an essential role in the regulation of plant responses to various environmental abiotic and biotic stresses. Among the most severe stresses are herbivory, pathogen infection, and drought stress. The major hormones involved in the regulation of these responses are 12-oxo-phytodienoic acid (OPDA), the pro-hormone jasmonic acid (JA) and its biologically active isoleucine conjugate (JA-Ile), salicylic acid (SA), and abscisic acid (ABA). These signaling compounds are present and biologically active at very low concentrations from ng/g to μg/g dry weight. Accurate and sensitive quantification of these signals has made a significant contribution to the understanding of plant stress responses. Ultra-performance liquid chromatography (UPLC) coupled with a tandem quadrupole mass spectrometer (MS/MS) has become an essential technique for the analysis and quantification of these compounds.
Man, Zhengyin; Wang, Quanlin; Li, Hesheng; Zhang, Aizhi
2014-12-01
A comprehensive analytical method based on ultra-performance liquid chromatography coupled with triple quadrupole mass spectrometry (UPLC-MS/MS) has been developed for the simultaneous determination of 33 primary aromatic amines (PAAs) in fine pigments such as gouache paint, oil painting pigment and acrylic paint. The primary aromatic amines in samples were extracted with acetonitrile. Then the extract was concentrated by centrifugation and nitrogen blow, finally diluted to 2 mL with methanol-water (1:9, v/v) and filtered through 0. 22 im membrane before UPLC-MS/MS analysis. The analytes were separated on a BEH Phenyl column (100 mm x 2. 1 mm, 1. 7 1µm) with 0. 07% (v/v) formic acid in methanol-water as mobile phases in gradient elution. The PAAs were detected by UPLC-MS/MS under multiple reaction monitoring (MRM) mode and quantified by the internal standard method. The separation conditions, fragment voltages and collision energies were optimized. The impacts of extraction times, extraction solvents and concentration methods on recoveries were studied. The limits of detection and limits of quantitation for the 33 primary aromatic amines were 5-50 µg/kg and 15-150 µg/kg respectively. The mean recoveries of three different dye products at three spiked levels were 70. 1% - 115. 8%. The relative standard deviations were 2. 1% - 15%. The expenmental results indicated that the method is simple, rapid, sensitive, accurate and can meet the requirements for the determination.
NASA Astrophysics Data System (ADS)
Yan, Zhixiang; Lin, Ge; Ye, Yang; Wang, Yitao; Yan, Ru
2014-06-01
Flavonoids are one of the largest classes of plant secondary metabolites serving a variety of functions in plants and associating with a number of health benefits for humans. Typically, they are co-identified with many other secondary metabolites using untargeted metabolomics. The limited data quality of untargeted workflow calls for a shift from the breadth-first to the depth-first screening strategy when a specific biosynthetic pathway is focused on. Here we introduce a generic multiple reaction monitoring (MRM)-based approach for flavonoids profiling in plants using a hybrid triple quadrupole linear ion trap (QTrap) mass spectrometer. The approach includes four steps: (1) preliminary profiling of major aglycones by multiple ion monitoring triggered enhanced product ion scan (MIM-EPI); (2) glycones profiling by precursor ion triggered EPI scan (PI-EPI) of major aglycones; (3) comprehensive aglycones profiling by combining MIM-EPI and neutral loss triggered EPI scan (NL-EPI) of major glycone; (4) in-depth flavonoids profiling by MRM-EPI with elaborated MRM transitions. Particularly, incorporation of the NH3 loss and sugar elimination proved to be very informative and confirmative for flavonoids screening. This approach was applied for profiling flavonoids in Astragali radix ( Huangqi), a famous herb widely used for medicinal and nutritional purposes in China. In total, 421 flavonoids were tentatively characterized, among which less than 40 have been previously reported in this medicinal plant. This MRM-based approach provides versatility and sensitivity that required for flavonoids profiling in plants and serves as a useful tool for plant metabolomics.
Huang, Meilin; Cheng, Zhongzhe; Wang, Lu; Feng, Yulin; Huang, Jiangeng; Du, Zhifeng; Jiang, Hongliang
2018-05-29
It is challenging to conduct in vivo metabolic study for traditional Chinese medicines (TCMs) because of complex components, unpredictable metabolic pathways and low metabolite concentrations. Herein, we proposed a sensitive strategy to characterize TCM metabolites in vivo at an orally clinical dose using ultra-high performance liquid chromatography-triple quadrupole-linear ion trap mass spectrometry (UHPLC-QTRAP-MS). Firstly, the metabolism of individual compounds in rat liver microsomes was studied to obtain the metabolic pathways and fragmentation patterns. The untargeted metabolites in vitro were detected by multiple ion monitoring-enhanced product ion (EPI) and neutral loss-EPI scans. Subsequently, a sensitive multiple reaction monitoring-EPI method was developed according to the in vitro results and predicted metabolites to profile the in vivo metabolites. Licorice as a model herb was used to evaluate and validate our strategy. A clinical dose of licorice water extract was orally administered to rats, then a total of 45 metabolites in urine, 21 metabolites in feces and 35 metabolites in plasma were detected. Among them, 18 minor metabolites have not been reported previously and 6 minor metabolites were first detected in vivo. Several isomeric metabolites were well separated and differentiated in our strategy. These results suggested that this new strategy could be widely used for the detection and characterization of in vivo metabolites of TCMs. Copyright © 2018. Published by Elsevier B.V.
Adhikari, Puspa L; Wong, Roberto L; Overton, Edward B
2017-10-01
Accurate characterization of petroleum hydrocarbons in complex and weathered oil residues is analytically challenging. This is primarily due to chemical compositional complexity of both the oil residues and environmental matrices, and the lack of instrumental selectivity due to co-elution of interferences with the target analytes. To overcome these analytical selectivity issues, we used an enhanced resolution gas chromatography coupled with triple quadrupole mass spectrometry in Multiple Reaction Monitoring (MRM) mode (GC/MS/MS-MRM) to eliminate interferences within the ion chromatograms of target analytes found in environmental samples. This new GC/MS/MS-MRM method was developed and used for forensic fingerprinting of deep-water and marsh sediment samples containing oily residues from the Deepwater Horizon oil spill. The results showed that the GC/MS/MS-MRM method increases selectivity, eliminates interferences, and provides more accurate quantitation and characterization of trace levels of alkyl-PAHs and biomarker compounds, from weathered oil residues in complex sample matrices. The higher selectivity of the new method, even at low detection limits, provides greater insights on isomer and homolog compositional patterns and the extent of oil weathering under various environmental conditions. The method also provides flat chromatographic baselines for accurate and unambiguous calculation of petroleum forensic biomarker compound ratios. Thus, this GC/MS/MS-MRM method can be a reliable analytical strategy for more accurate and selective trace level analyses in petroleum forensic studies, and for tacking continuous weathering of oil residues. Copyright © 2017 Elsevier Ltd. All rights reserved.
Xia, Li; Ouyang, Pu-Yue; Gao, Wen; Yi, Tao; Zhang, Xian-Tao; Zhao, Zhen-Dong; Yang, Hua
2016-07-01
A rapid and validated method using ultra high-performance liquid chromatography coupled with a triple quadrupole mass spectrometry (UHPLC-QQQ MS) was developed for simultaneous determination of four active steroidal saponins, i.e., dichotomin ( 1: ), pennogenin 3-O-α-l-arabinofuranosyl-(1→4)-[α-l-rhamnopyranosyl-(1→2)]-β-d-glucopyranoside ( 2: ), pennogenin 3-O-α-l-rhamnopyranosyl-(1→2)-[α-l-rhamnopyranosyl-(1→4)-α-l-rhamnopyranosyl-(1→4)]-β-d-glucopyranoside ( 3: ) and diosgenin 3-O-α-l-rhamnopyranosyl-(1→2)-[α-l-rhamnopyranosyl-(1→4)-α-l-rhamnopyranosyl-(1→4)]-β-d-glucopyranosidein ( 4: ), in Ypsilandra thibetica Franch. The optimized sample preparation and UHPLC-QQQ MS conditions were chosen for quantitative analysis. The separation was performed on an Agilent Zorbax Eclipse Plus C18 column (2.1 mm × 50 mm, 1.8 µm) with gradient elution of acetonitrile-0.1% formic acid in water. All calibration curves showed good linear regression (r> 0.9985) within the test range. The limits of detection and quantification were in the range of 0.02-4.40 and 0.04-22.0 ng/mL, respectively. The proposed method was applied to analyze two batches of Y. thibetica samples for target compounds within 10 min. This work promoted the quality control method for raw material or preparations of Y. thibetica. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Monteleone, Marcello; Naccarato, Attilio; Sindona, Giovanni; Tagarelli, Antonio
2012-08-17
The work aims at developing a rapid and sensitive method for the quantification of perfluorocarboxylic acids in aqueous matrices. The proposed analytical approach is based on the use of solid phase microextraction in headspace mode after a fast derivatization of the carboxylate function by propylchloroformate/propanol mixture. Several fibers were evaluated and the optimization of the parameters affecting the SPME process was carried out using a central composite design. The optimum working conditions in terms of response values were achieved by performing analysis with CAR/PDMS fiber at room temperature, without addition of NaCl, with a sample volume of 6 ml and an extraction time of 10 min. Assay of PFCAs was performed by using a gas chromatography-triple quadrupole mass spectrometry (GC-QqQ MS) system in negative chemical ionization mode with ammonia as reagent gas. An overall evaluation of all analytical parameters shows that the proposed method provides satisfactory results. In particular, the observed accuracies, ranging from 84.4% to 116.8%, and the RSD values in the range 0.4% and 14.5% confirm the effectiveness of the developed protocol in the assay of PFCAs content in aqueous matrices. Moreover, LOD and LOQ values ranging from 0.08 to 6.6 ng l(-1) and from 0.17 to 14.3 ng l(-1), respectively, can be considered very satisfactory. None of the compounds were detected in six samples of river collected in Calabria. Copyright © 2012 Elsevier B.V. All rights reserved.
Mass spectrometric profiling of flavonoid glycoconjugates possessing isomeric aglycones.
Abrankó, László; Szilvássy, Blanka
2015-01-01
In fields such as food and nutrition science or plant physiology, interest in untargeted profiling of flavonoids continues to expand. The group of flavonoids encompasses several thousands of chemically distinguishable compounds, among which are a number of isobaric compounds with the same elemental composition. Thus, the mass spectrometric identification of these compounds is challenging, especially when reference standards are not available to support their identification. Many different types of isomers of flavonoid glycoconjugates are known, i.e. compounds that differ in their glycosylation position, glycan sequence or type of interglycosidic linkage. This work focuses on the mass spectrometric identification of flavonoid glycoconjugate isomers possessing the same glycan mass and differing only in their aglycone core. A non-targeted HPLC-ESI-MS/MS profiling method using a triple quadrupole MS is presented herein, which utilizes in-source fragmentation and a pseudo-MS(3) approach for the selective analysis of flavonoid glycoconjugates with isomeric/isobaric aglycones. A selective MRM-based identification of the in-source formed isobaric aglycone fragments was established. Additionally, utilizing the precursor scanning capability of the employed triple quadrupole instrument, the developed method enabled the determination of the molecular weight of the studied intact flavonoid glycoconjugate. The versatility of the method was proven with various types of flavonoid aglycones, i.e. anthocyanins, flavonols, flavones, flavanones and isoflavones, along with their representative glycoconjugates. The developed method was also successfully applied to a commercially available sour cherry sample, in which 16 different glycoconjugates of pelargonidin, genistein, cyanidin, kaempferol and quercetin could be tentatively identified, including a number of compounds containing isomeric/isobaric aglycones. Copyright © 2015 John Wiley & Sons, Ltd.
Wang, He-xing; Wang, Bin; Zhou, Ying; Jiang, Qing-wu
2013-05-01
Steroid hormone levels in human urine are convenient and sensitive indicators for the impact of phthalates and/or bisphenol A (BPA) exposure on the human steroid hormone endocrine system. In this study, a rapid and sensitive method for determination of 14 phthalate metabolites, BPA, and ten endogenous steroid hormones in urine was developed and validated on the basis of ultra-performance liquid chromatography coupled with electrospray ionization triple quadrupole mass spectrometry. The optimized mixed-mode solid phase-extraction separated the weakly acidic or neutral BPA and steroid hormones from acidic phthalate metabolites in urine: the former were determined in positive ion mode with a methanol/water mobile phase containing 10 mM ammonium formate; the latter were determined in negative ion mode with a acetonitrile/water mobile phase containing 0.1 % acetic acid, which significantly alleviated matrix effects for the analysis of BPA and steroid hormones. Dansylation of estrogens and BPA realized simultaneous and sensitive analysis of the endogenous steroid hormones and BPA in a single chromatographic run. The limits of detection were less than 0.84 ng/mL for phthalate metabolites and less than 0.22 ng/mL for endogenous steroid hormones and BPA. This proposed method had satisfactory precision and accuracy, and was successfully applied to the analyses of human urine samples. This method could be valuable when investigating the associations among endocrine-disrupting chemicals, endogenous steroid hormones, and relevant adverse outcomes in epidemiological studies.
NASA Astrophysics Data System (ADS)
Adhikari, P. L.; Overton, E. B.; Maiti, K.; Wong, R. L.
2016-02-01
Petroleum biomarkers such as hopanes, steranes, and triaromatic steroids are more persistent than alkanes and aromatic compounds. Thus, they are often used to track spilled oil in the environments and as a proxy for weathering processes. The present study utilizes water samples, suspended and sinking particles, and seafloor sediments collected during 2011-2013 from various locations of the northern Gulf of Mexico with wide range of contaminated oil for Deepwater Horizon (DWH) oil fingerprinting. The MC252 source oil along with the samples collected in this study were analyzed using a gas chromatography coupled with a triple quadrupole mass spectrometry (GC/MS/MS) in Multiple Reaction Monitoring (MRM) mode and the results were compared with results from commonly used GC/MS selective ion monitoring (SIM) method. The results indicate that the MRM method separates interfering ions from interfering compounds and can be a powerful analytical strategy for a reliable identification and determination of trace levels of biomarkers in complex matrices. Source indicators such as the MRM fragment ion chromatograms of the biomarkers and their diagnostic ratios in samples were compared with the MC252 source oil. The preliminary results show that the biomarkers were below detection limits in dissolved samples. However, in few particulate and seafloor sediment samples, primarily from the immediate vicinity of the Macondo wellhead, contained their patterns. The results also illustrate that these biomarker compounds have been weathered within 1-3 years following the oil spill, and their DWH oil signature in some of these samples reflects this weathering.
Mulet, Carmen T; Arroyo-Mora, Luis E; Leon, Lorena A; Gnagy, Elizabeth; DeCaprio, Anthony P
2018-06-20
Methylphenidate (MPH), which is metabolized into ritalinic acid (RA), is an amphetamine derivative largely used in the treatment of attention-deficit hyperactivity disorder, a neurological condition commonly diagnosed in early childhood. Ensuring that patients comply with clinical treatment is crucial and compliance is generally monitored in blood or urine specimens which, especially in the case of children, can be challenging to obtain on a repetitive basis. Here we report validation of a specific, non-invasive, and rapid dilute-and-shoot analytical method for the detection and quantitation of MPH and RA in oral fluid (OF). The method is based on liquid chromatography coupled to triple quadrupole MS with electrospray ionization utilizing dynamic MRM mode. Subject OF specimens were collected using a Quantisal™ device, processed, and diluted for analysis with seven-point quadratic calibration curves (weighting of 1/x) using MPH-d 9 and (±)-threo-RA-d 10 as internal standards. QC samples and diluted specimens showed intra- and inter-day bias and imprecision values no greater than ±12%. The LOD and LOQ for MPH were 0.1 and 0.5 ng/mL, respectively, and 0.2 ng/mL and 0.5 ng/mL for RA, respectively, indicating the validity of the method for identification and confirmation at low concentrations. Selectivity was specific for the analytes of interest and matrix effects were minimized through the use of internal standard based quantitation. Copyright © 2018 Elsevier B.V. All rights reserved.
Beam shaping assembly optimization for (7)Li(p,n)(7)Be accelerator based BNCT.
Minsky, D M; Kreiner, A J
2014-06-01
Within the framework of accelerator-based BNCT, a project to develop a folded Tandem-ElectroStatic-Quadrupole accelerator is under way at the Atomic Energy Commission of Argentina. The proposed accelerator is conceived to deliver a proton beam of 30mA at about 2.5MeV. In this work we explore a Beam Shaping Assembly (BSA) design based on the (7)Li(p,n)(7)Be neutron production reaction to obtain neutron beams to treat deep seated tumors. © 2013 Elsevier Ltd. All rights reserved.
Webb, Ian K; Londry, Frank A; McLuckey, Scott A
2011-09-15
Means for effecting dipolar direct current collision-induced dissociation (DDC CID) on a quadrupole/time-of-flight in a mass spectrometer have been implemented for the broadband dissociation of a wide range of analyte ions. The DDC fragmentation method in electrodynamic storage and transmission devices provides a means for inducing fragmentation of ions over a large mass-to-charge range simultaneously. It can be effected within an ion storage step in a quadrupole collision cell that is operated as a linear ion trap or as ions are continuously transmitted through the collision cell. A DDC potential is applied across one pair of rods in the quadrupole collision cell of a QqTOF hybrid mass spectrometer to effect fragmentation. In this study, ions derived from a small drug molecule, a model peptide, a small protein, and an oligonucleotide were subjected to the DDC CID method in either an ion trapping or an ion transmission mode (or both). Several key experimental parameters that affect DDC CID results, such as time, voltage, low mass cutoff, and bath gas pressure, are illustrated with protonated leucine enkephalin. The DDC CID dissociation method gives a readily tunable, broadband tool for probing the primary structures of a wide range of analyte ions. The method provides an alternative to the narrow resonance conditions of conventional ion trap CID and it can access more extensive sequential fragmentation, depending upon conditions. The DDC CID approach constitutes a collision analog to infrared multiphoton dissociation (IRMPD). Copyright © 2011 John Wiley & Sons, Ltd.
Dong, Yinfeng; Tang, Minghai; Song, Hang; Li, Rong; Wang, Chunyu; Ye, Haoyu; Qiu, Neng; Zhang, Yongkui; Chen, Lijuan; Wei, Yuquan
2014-03-15
As fecal excretion is one of important routes of elimination of drugs and their metabolites, it is indispensable to investigate the metabolites in feces for more comprehensive information on biotransformation in vivo. In this study, a sensitive and reliable approach based on ultra-performance liquid chromatography/quadrupole-time-of-flight-mass spectrometry (UHPLC-Q-TOF-MS) was applied to characterize the metabolic profile of honokiol in rat feces after the administration of an equimolar mixture of honokiol and [(13)C6]-labeled honokiol. Totally 42 metabolites were discovered and tentatively identified in rat feces samples, 26 metabolites were first reported, including two novel classes of metabolites, methylated and dimeric metabolites of honokiol. Moreover, this study provided basic comparative data on the metabolites in rat plasma, feces and urine, which gave better understanding of the metabolic fate of honokiol in vivo. Copyright © 2014 Elsevier B.V. All rights reserved.
Amorisco, A; Locaputo, V; Mascolo, G
2011-07-15
The structural elucidation of carbonyl-containing by-products arising from Uniblu-OH ozonation has been investigated by liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) employing a quadrupole time-of-flight mass spectrometer. The by-products were derivatized with 2,4-dinitrophenylhydrazine, allowing the formation of [M-H](-) ions of the derivatives in the electrospray source. Exact mass measurements of both the [M-H](-) ions and their product ions allowed the elemental formulae and related structures of ten by-products to be determined confidently. The main degradation pathway were decarboxylation followed by further oxidation. It is noteworthy that the experimental procedure employed allowed the identification of both nitrogen- and sulphur-containing carbonyl by-products during Uniblu-OH ozonation. This result is of environmental relevance for monitoring the balance of organic nitrogen and sulphur during the ozonation of organic pollutants. These atoms, in fact, do not undergo complete mineralization. Copyright © 2011 John Wiley & Sons, Ltd.
Synthesis and analytical follow-up of the mineralization of a new fluorosurfactant prototype.
Peschka, M; Fichtner, N; Hierse, W; Kirsch, P; Montenegro, E; Seidel, M; Wilken, R D; Knepper, T P
2008-08-01
Fluorinated surfactants have become essential in numerous technical applications due to their unparalleled effectiveness and efficiency. The environmental persistence of the non-biodegradable perfluorinated alkyl moiety has become a matter of concern. Therefore, it was searched for new molecules with chemically stable fluorinated end groups which can be microbially transformed into labile fluorinated substances. One prototype substance, 10-(trifluoromethoxy)decane-1-sulfonate, has shown biomineralization. Monitoring the formation of metabolites over time elucidated the mechanism of biotransformation. Analysis was performed utilizing liquid chromatography-single quadrupole mass spectrometry (LC-MS) and quadrupole-time of flight tandem mass spectrometry (QqTOF-MS). It was possible to distinguish between two major degradation pathways of the fluorinated alkylsulfonate derivative: (i) a desulfonation and subsequent oxidation and degradation of the alkyl chain being predominant and (ii) an insertion of oxygen with a subsequent cleavage and degradation of the molecule. The utilized trifluoromethoxy-endgroup resulted in instable trifluoromethanol after degradation of the alkyl chain, which led to a high degree of mineralization of the molecule.
Székely, Gy; Henriques, B; Gil, M; Ramos, A; Alvarez, C
2012-11-01
The present study reports on a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method development strategy supported by design of experiments (DoE) for the trace analysis of 4-dimethylaminopyridine (DMAP). The conventional approaches for development of LC-MS/MS methods are usually via trial and error, varying intentionally the experimental factors which is time consuming and interactions between experimental factors are not considered. The LC factors chosen for the DoE study include flow (F), gradient (G) and injection volume (V(inj)) while cone voltage (E(con)) and collision energy (E(col)) were chosen as MS parameters. All of the five factors were studied simultaneously. The method was optimized with respect to four responses: separation of peaks (Sep), peak area (A(peak)), length of the analysis (T) and the signal to noise ratio (S/N). A quadratic model, namely central composite face (CCF) featuring 29 runs was used instead of a less powerful linear model since the increase in the number of injections was insignificant. In order to determine the robustness of the method a new set of DoE experiments was carried out applying robustness around the optimal conditions was evaluated applying a fractional factorial of resolution III with 11 runs, wherein additional factors - such as column temperature and quadrupole resolution - were considered. The method utilizes a Phenomenex Gemini NX C-18 HPLC analytical column with electrospray ionization and a triple quadrupole mass detector in multiple reaction monitoring (MRM) mode, resulting in short analyses with a 10min runtime. Drawbacks of derivatization, namely incomplete reaction and time consuming sample preparation, have been avoided and the change from SIM to MRM mode resulted in increased sensitivity and lower LOQ. The DoE method development strategy led to a method allowing the trace analysis of DMAP at 0.5 ng/ml absolute concentration which corresponds to a 0.1 ppm limit of quantification in 5mg/ml mometasone furoate glucocorticoid. The obtained method was validated in a linear range of 0.1-10 ppm and presented a %RSD of 0.02% for system precision. Regarding DMAP recovery in mometasone furoate, spiked samples produced %recoveries between 83 and 113% in the range of 0.1-2 ppm. Copyright © 2012 Elsevier B.V. All rights reserved.
She, Yongxin; Wang, Jing; Zheng, Yongquan; Cao, Weiqiang; Wang, Rongyan; Dong, Fengshou; Liu, Xingang; Qian, Mingrong; Zhang, Hu; Wu, Liqing
2012-05-01
A method has been developed for the simultaneous determination of the concentration of nonylphenol (4-NP), nonylphenol monoethoxylates (NP1EO) and nonylphenol diethoxylates (NP2EO) in vegetables and crops by liquid chromatography-tandem quadrupole mass spectrometry (HPLC-MS/MS). These target compounds were extracted from vegetable and crop samples with acetonitrile, and then the extracts were cleaned using solid phase extraction with graphitised carbon black tandem primary secondary amine (PSA) cartridges. The MS method enabled highly reliable identification by monitoring the corresponding ammonium adduct [M+NH4](+) in the positive mode for NP1EO and NP2EO, and the deprotonated molecule [M-H](-) in the negative mode for 4-NP. Recoveries for the spiked samples ranged from 65% to 118%. The limit of detection (LOD) of 4-NP, NP1EO and NP2EO was 3, 5 and 0.1μgkg(-1), respectively. This method would be useful for the quick and routine detection of the residues of 4-NP, NP1EO and NP2EO in vegetables and crops. Copyright © 2011 Elsevier Ltd. All rights reserved.
Clinical development of imatinib: an anticancer drug
Goswami, Dipanjan; Gurule, Sanjay; Lahiry, Abhiroop; Anand, Amit; Khuroo, Arshad; Monif, Tausif
2016-01-01
Background: A novel and accurate high-throughput tandem mass spectroscopic method has been developed and validated for determination of imatinib, a protein-tyrosine kinase inhibitor against chronic myeloid leukemia. Materials & methods: Chromatographic separation was carried on XTerra® RP18 column (150 mm × 4.6 mm, 5 µm particle size) manufactured by Waters Corporation, MA, USA. The detection was performed on a triple quadruple tandem mass spectrometer by multiple reactions monitoring mode via electrospray ionization source. Results: The selective and sensitive method was linear in the concentration range of 9.57–4513.29 ng/ml and reported no matrix effect. Conclusion: The mean Cmax was found to be 10–15% lower in European subjects as compared with Indian subjects. PMID:28031942
NASA Astrophysics Data System (ADS)
Kumar, Pradeep; Li, Cheng-Bin; Sahoo, B. K.
2018-03-01
Dependencies of electron correlation effects with the rank and radial behavior of spectroscopic properties are analyzed in the singly charged calcium ion (Ca+). To demonstrate these trends, we have determined field shift constants, magnetic dipole and electric quadrupole hyperfine structure constants, Landé g J factors, and electric quadrupole moments that are described by electronic operators with different radial and angular factors. Radial dependencies are investigated by comparing correlation trends among the properties that have similar angular factors and vice versa. To highlight these observations, we present results from the mean-field approach to all-orders along with intermediate contributions. Contributions from higher relativistic corrections are also given. These findings suggest that sometime lower-order approximations can give results agreeing with the experimental results, but inclusion of some of higher-order correlation effects can cause large disagreement with the experimental values. Therefore, validity of a method for accurate evaluation of atomic properties can be tested by performing calculations of several properties simultaneously that have diverse dependencies on the angular and radial factors and comparing with the available experimental results. Nevertheless, it is imperative to include full triple and quadrupole excitations in the all-order many-body methods for high-precision calculations that are yet to be developed adopting spherical coordinate system for atomic studies.
Zhao, Yuan Yuan; Liu, Xin; Boyd, Jessica M; Qin, Feng; Li, Jianjun; Li, Xing-Fang
2009-01-01
We report a nanoelectrospray ionization (nESI) with high-field asymmetric waveform ion mobility spectrometry (FAIMS) and tandem mass spectrometry (MS-MS) method for determination of small molecules of m/z 50 to 200 and its potential application in environmental analysis. Integration of nESI with FAIMS and MS-MS combines the advantages of these three techniques into one method. The nESI provides efficient sample introduction and ionization and allows for collection of multiple data from only microliters of samples. The FAIMS provides rapid separation, reduces or eliminates background interference, and improves the signal-to-noise ratio as much as 10-fold over nESI-MS-MS. The tandem quadrupole time-of-flight MS detection provides accurate mass and mass spectral measurements for structural identification. Characteristics of FAIMS compensation voltage (CV) spectra of seven nitrosamines, N-nitrosodimethylamine (NDMA), N-nitrosomethylethylamine (NMEA), N-nitrosodiethylamine (NDEA), N-nitrosodi-n-propylamine (NDPA), N-nitrosodi-n-butylamine (NDBA), N-nitrosopiperidine (NPip), and N-nitrosopyrrolidine (NPyr), were analyzed. The optimal CV of the nitrosamines (at DV -4000 V) were: -1.6 V, NDBA; 2.6 V, NDPA; 6.6 V, NPip; 8.8 V, NDEA; 13.2 V, NPyr; 14.4 V, NMEA; and 19.4 V, NDMA. Fragmentation patterns of the seven nitrosamines in the nESI-FAIMS-MS-MS were also obtained. The specific CV and MS-MS spectra resulted in positive identification of NPyr and NPip in a treated water sample, demonstrating the potential application of this technique in environmental analysis.
Letcher, R J; Li, H X; Chu, S G
2005-01-01
Hydroxylated metabolites of polychlorinated biphenyls (HO-PCBs) and pentachlorophenol (PCP) are halogenated phenolic compounds, and they are increasingly common as environmental contaminants mainly in the blood of wildlife and humans. A methodology based on high-performance liquid chromatography (reversed-phase)-electrospray (negative) ionization-tandem quadrupole mass spectrometry (LC-ESI(-)-MS-MS) in the select ion monitoring or multiple reaction monitoring modes was developed for HO-PCB and PCP determination in blood plasma and serum. Among 11 environmentally relevant HO-PCB congeners and PCP spiked to fetal calf serum, quantitative assessments, including matrix effects on ESI(-) suppression/ enhancement, showed process (recovery) efficiencies of 73% to 89% without internal standard (IS) correction, and 88% to 103% with IS correction, and method limits of quantification ranging from 1 to 50 pg/g (wet weight). Using the developed LC-ESI(-)-MS methodology in comparison with GC-MS and GC-ECD based approaches, similar results were found for HO-PCB identification and quantification in the plasma of polar bear (Ursus maritimus) from the Canadian arctic. LC-ESI(-)-MS identified four HO-PCB congeners [4'-HO-2,2',4,6,6'-pentachlorobiphenyl (4'-HO-CB104), 4-HO-2,3,3',4',5-pentachlorobiphenyl (4-HO-CB107), 4-HO-2,3,3',5,5',6-hexachlorobiphenyl (4-HO-CB165) and 3'-HO-2,2',3,4,4',5,5'-heptachlorobiphenyl (3'-HO-CB180)], and 14 additional tetra- to hepta-chlorinated HO-PCBs isomers in the polar bear plasma.
Kumar, Sunil; Singh, Awantika; Bajpai, Vikas; Srivastava, Mukesh; Singh, Bhim Pratap; Kumar, Brijesh
2016-12-01
Rauwolfia species (Apocynaceae) are medicinal plants well known worldwide due to its potent bioactive monoterpene indole alkaloids (MIAs) such as reserpine, ajmalicine, ajmaline, serpentine and yohimbine. Reserpine, ajmalicine and ajmaline are powerful antihypertensive, tranquilizing agents used in hypertension. Yohimbine is an aphrodisiac used in dietary supplements. As there is no report on the comparative and comprehensive phytochemical investigation of the roots of Rauwolfia species, we have developed an efficient and reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for ethanolic root extract of Rauwolfia species to elucidate the fragmentation pathways for dereplication of bioactive MIAs using high-performance liquid chromatography coupled with electrospray ionization quadrupole time-of-flight tandem mass spectrometry (HPLC-ESI-QTOF-MS/MS) in positive ion mode. We identified and established diagnostic fragment ions and fragmentation pathways using reserpine, ajmalicine, ajmaline, serpentine and yohimbine. The MS/MS spectra of reserpine, ajmalicine, and ajmaline showed C -ring-cleavage whereas E -ring cleavage was observed in serpentine via Retro Diels Alder (RDA). A total of 47 bioactive MIAs were identified and characterized on the basis of their molecular formula, exact mass measurements and MS/MS analysis. Reserpine, ajmalicine, ajmaline, serpentine and yohimbine were unambiguously identified by comparison with their authentic standards and other 42 MIAs were tentatively identified and characterized from the roots of Rauwolfia hookeri, Rauwolfia micrantha, Rauwolfia serpentina, Rauwolfia verticillata, Rauwolfia tetraphylla and Rauwolfia vomitoria . Application of LC-MS followed by principal component analysis (PCA) has been successfully used to discriminate among six Rauwolfia species.
Fontana, Ariel; Rodríguez, Isaac; Cela, Rafael
2017-09-15
A new reliable method for the determination 3-alkyl-2-methoxypyrazines (MPs) in wine samples based on the sequential combination of solid-phase extraction (SPE), dispersive liquid-liquid microextraction (DLLME) and gas chromatography (GC) quadrupole time-of-flight accurate tandem mass spectrometry (QTOF-MS/MS) is presented. Primary extraction of target analytes was carried out by using a reversed-phase Oasis HLB (200mg) SPE cartridge combined with acetonitrile as elution solvent. Afterwards, the SPE extract was submitted to DLLME concentration using 0.06mL carbon tetrachloride (CCl 4 ) as extractant. Under final working conditions, sample concentration factors above 379 times and limits of quantification (LOQs) between 0.3 and 2.1ngL -1 were achieved. Moreover, the overall extraction efficiency of the method was unaffected by the particular characteristics of each wine; thus, accurate results (relative recoveries from 84 to 108% for samples spiked at concentrations from 5 to 25ngL -1 ) were obtained using matrix-matched standards, without using standard additions over every sample. Highly selective chromatographic records were achieved considering a mass window of 5mDa, centered in the quantification product ion corresponding to each compound. Twelve commercial wines, elaborated with grapes from different varieties and geographical origins, were processed with the optimized method. The 2-isobutyl-3-methoxypyrazine (IBMP) was determined at levels above the LOQs of the method in half of the samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Cui, Qingling; Pan, Yingni; Yan, Xiaowei; Qu, Bao; Liu, Xiaoqiu; Xiao, Wei
2017-02-28
Isoacteoside (ISAT), a phenylethanoid glycoside that acts as the principal bioactive component in traditional Chinese medicines, possesses broad pharmacological effects such as neuroprotective, antihypertensive and hepatoprotective activities. However, its pharmaceutical development has been severely limited due to the poor oral bioavailability. It is essential and significant to investigate related hurdles leading to the poor bioavailability of isoacteoside. Whole animal metabolism studies were conducted in rats, followed by metabolic mechanism including gastrointestinal stability, intestinal flora metabolism and intestinal enzyme metabolism employing the powerful method ultrahigh-performance liquid chromatography combined with quadrupole time-of-flight tandem mass spectrometry (UPLC/QTOF-MS/MS). A simple, rapid and sensitive method has been developed which comprehensively revealed the underlying cause of poor bioavailability of ISAT in a metabolic manner. The prototype of ISAT and its combined metabolites have not been detected in plasma. Furthermore, the residual content of the parent compound in in vitro experiments was approximately 59%, 5% and barely none in intestinal bacteria, intestinal S9 and simulated intestinal juice at 6 h, respectively. The present work has demonstrated that the factors causing the poor bioavailability of isoacteoside should be attributed to the metabolism. In general, the metabolism that resulted from intestinal flora and intestinal enzymes were predominant reasons giving rise to the poor bioavailability of ISAT, which also suggested that metabolites might be responsible for the excellent pharmacological effect of ISAT. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Auray-Blais, Christiane; Maranda, Bruno; Lavoie, Pamela
2014-09-25
Creatine synthesis and transport disorders, Triple H syndrome and ornithine transcarbamylase deficiency are treatable inborn errors of metabolism. Early screening of patients was found to be beneficial. Mass spectrometry analysis of specific urinary biomarkers might lead to early detection and treatment in the neonatal period. We developed a high-throughput mass spectrometry methodology applicable to newborn screening using dried urine on filter paper for these aforementioned diseases. A high-throughput methodology was devised for the simultaneous analysis of creatine, guanidineacetic acid, orotic acid, uracil, creatinine and respective internal standards, using both positive and negative electrospray ionization modes, depending on the compound. The precision and accuracy varied by <15%. Stability during storage at different temperatures was confirmed for three weeks. The limits of detection and quantification for each biomarker varied from 0.3 to 6.3 μmol/l and from 1.0 to 20.9 μmol/l, respectively. Analyses of urine specimens from affected patients revealed abnormal results. Targeted biomarkers in urine were detected in the first weeks of life. This rapid, simple and robust liquid chromatography/tandem mass spectrometry methodology is an efficient tool applicable to urine screening for inherited disorders by biochemical laboratories. Copyright © 2014 Elsevier B.V. All rights reserved.
Tex, David M; Nakamura, Tetsuya; Imaizumi, Mitsuru; Ohshima, Takeshi; Kanemitsu, Yoshihiko
2017-05-16
Tandem solar cells are suited for space applications due to their high performance, but also have to be designed in such a way to minimize influence of degradation by the high energy particle flux in space. The analysis of the subcell performance is crucial to understand the device physics and achieve optimized designs of tandem solar cells. Here, the radiation-induced damage of inverted grown InGaP/GaAs/InGaAs triple-junction solar cells for various electron fluences are characterized using conventional current-voltage (I-V) measurements and time-resolved photoluminescence (PL). The conversion efficiencies of the entire device before and after damage are measured with I-V curves and compared with the efficiencies predicted from the time-resolved method. Using the time-resolved data the change in the carrier dynamics in the subcells can be discussed. Our optical method allows to predict the absolute electrical conversion efficiency of the device with an accuracy of better than 5%. While both InGaP and GaAs subcells suffered from significant material degradation, the performance loss of the total device can be completely ascribed to the damage in the GaAs subcell. This points out the importance of high internal electric fields at the operating point.
Maia, Alexandra S; Ribeiro, Ana R; Amorim, Catarina L; Barreiro, Juliana C; Cass, Quezia B; Castro, Paula M L; Tiritan, Maria Elizabeth
2014-03-14
Antibiotics are a therapeutic class widely found in environmental matrices and extensively studied due to its persistence and implications for multi-resistant bacteria development. This work presents an integrated approach of analytical multi-techniques on assessing biodegradation of fluorinated antibiotics at a laboratory-scale microcosmos to follow removal and formation of intermediate compounds. Degradation of four fluoroquinolone antibiotics, namely Ofloxacin (OFL), Norfloxacin (NOR), Ciprofloxacin (CPF) and Moxifloxacin (MOX), at 10 mg L(-1) using a mixed bacterial culture, was assessed for 60 days. The assays were followed by a developed and validated analytical method of LC with fluorescence detection (LC-FD) using a Luna Pentafluorophenyl (2) 3 μm column. The validated method demonstrated good selectivity, linearity (r(2)>0.999), intra-day and inter-day precisions (RSD<2.74%) and accuracy. The quantification limits were 5 μg L(-1) for OFL, NOR and CPF and 20 μg L(-1) for MOX. The optimized conditions allowed picturing metabolites/transformation products formation and accumulation during the process, stating an incomplete mineralization, also shown by fluoride release. OFL and MOX presented the highest (98.3%) and the lowest (80.5%) extent of degradation after 19 days of assay, respectively. A representative number of samples was selected and analyzed by LC-MS/MS with triple quadrupole and the molecular formulas were confirmed by a quadruple time of flight analyzer (QqTOF). Most of the intermediates were already described as biodegradation and/or photodegradation products in different conditions; however unknown metabolites were also identified. The microbial consortium, even when exposed to high levels of FQ, presented high percentages of degradation, never reported before for these compounds. Copyright © 2014 Elsevier B.V. All rights reserved.
Mitamura, Kuniko; Satoh née Okihara, Rika; Kamibayashi, Mami; Sato, Kanta; Iida, Takashi; Ikegawa, Shigeo
2014-07-01
A liquid chromatography (LC)/electrospray ionization (ESI)-mass spectrometry (MS) method for the direct determination of eighteen tetrahydrocorticosteroid sulfates in human urine has been developed. The analytes were 3- and 21-monosulfates and 3,21-disulfates of tetrahydrocortisol (THF), tetrahydrocortisone (THE), tetrahydro-11-deoxycortisol (THS), and their corresponding 5α-H stereoisomers. The mass spectrometric behavior of these sulfates in negative-ion ESI-MS/MS revealed the production of intense structure specific product ions within the same group of sulfates and permitted distinction between regioisomeric sulfates by collision-induced fragmentation with the MS/MS technique using a linear ion-trap instrument. For the quantitative analysis, selected reaction monitoring analysis in the negative-ion detection mode using triple-stage quadrupole mass spectrometer was performed by monitoring transitions from [M-H](-) to the most abundant product ion of each tetrahydrocorticosteroid sulfate. After addition of 3- and 21-monosulfates of [2,2,3β,4,4-d5]-THF, -THE, and -THS as internal standards, urine sample was applied to a solid phase extraction using a lipophilic-weak anion exchange cartridge column, and then analyzed by LC/ESI-MS/MS. The method had satisfactory performance in terms of intra- and inter-assay precision (less than 9.7% and 9.6%, respectively), and accuracy (91.2-108.2%). The limit of quantification was lower than 2.5 ng/mL for all sulfates examined. We applied this method to determine the concentration of eighteen tetrahydrocorticosteroid sulfates in the urine of healthy subjects. Thus, we have developed a sensitive, precise and accurate assay for urinary tetrahydrocorticosteroid sulfates that should be useful for clinical and biological studies. Copyright © 2014 Elsevier Inc. All rights reserved.
Flavonoid Constituents of Phlomis (Lamiaceae) Species Using Liquid Chromatography Mass Spectrometry.
Aghakhani, Fatemeh; Kharazian, Navaz; Lori Gooini, Zahra
2018-03-01
Phlomis is one of the medicinal genera of Lamiaceae. This genus has unique medicinal properties. Consequently, appropriate methods need to be described for the identification of the chemical compounds. A liquid chromatography tandem mass spectrometry (LC-MS/MS) technique on a triple quadrupole mass spectrometer (TQMS) was used for separation and identification of leaf flavonoid compounds for seven Phlomis species including Phlomis kurdia, Ph. aucheri, Ph. olivieri, Ph. bruguieri, Ph. persica, Ph. anisodonta and Ph. elliptica. The flavonoid solution of air-dried leaves (10.5 g) was extracted using 85% methanol. The chromatogram was treated with three systems: methanol-water, chloroform-methanol and acetic acid. The extracts were analysed using LC-MS/MS. The MS 2 detection was performed under negative mode electrospray ionisation (ESI). The identification of constituents was based on authentic references used in the identification process. A total of 35 chemical compounds were detected from which 32 were identified as flavonoids through comparison with published literature and reference standards. These compounds were distributed in four flavonoid classes. Flavones (12), flavonols (11), flavanones (8) and flavane (1) were the main groups appearing in almost all of the studied samples. The flavonoids such as naringenin, chrysoeriol, eriodictyol, dimethoxyflavanone, apigenin, luteolin, kaempferol and rhamnetin were in high proportions. Moreover, 22 flavonoid compounds were first reported in this study for Phlomis species. The fragmentation patterns of the compounds during collision induced dissociation (CID) clarified information of the compounds analysed. The detailed flavonoid compositions of Phlomis species provide the appropriate context from phytochemical and phytotherapeutics points of view. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Porta, Tiffany; Grivet, Chantal; Knochenmuss, Richard; Varesio, Emmanuel; Hopfgartner, Gérard
2011-02-01
Analysis of low molecular weight compounds (LMWC) in complex matrices by vacuum matrix-assisted laser desorption/ionization (MALDI) often suffers from matrix interferences, which can severely degrade limits of quantitation. It is, therefore, useful to have available a range of suitable matrices, which exhibit complementary regions of interference. Two newly synthesized α-cyanocinnamic acid derivatives are reported here; (E)-2-cyano-3-(naphthalen-2-yl)acrylic acid (NpCCA) and (2E)-3-(anthracen-9-yl)-2-cyanoprop-2enoic acid (AnCCA). Along with the commonly used α-cyano-4-hydroxycinnamic acid (CHCA), and the recently developed 4-chloro-α-cyanocinnamic acid (Cl-CCA) matrices, these constitute a chemically similar series of matrices covering a range of molecular weights, and with correspondingly differing ranges of spectral interference. Their performance was compared by measuring the signal-to-noise ratios (S/N) of 47 analytes, mostly pharmaceuticals, with the different matrices using the selected reaction monitoring (SRM) mode on a triple quadrupole instrument equipped with a vacuum MALDI source. AnCCA, NpCCA and Cl-CCA were found to offer better signal-to-noise ratios in SRM mode than CHCA, but Cl-CCA yielded the best results for 60% of the compounds tested. To better understand the relative performance of this matrix series, the proton affinities (PAs) were measured using the kinetic method. Their relative values were: AnCCA > CHCA > NpCCA > Cl-CCA. This ordering is consistent with the performance data. The synthesis of the new matrices is straightforward and they provide (1) tunability of matrix background interfering ions and (2) enhanced analyte response for certain classes of compounds. Copyright © 2011 John Wiley & Sons, Ltd.
Crow, Brian S.; Pantazides, Brooke G.; Quiñones-González, Jennifer; Garton, Joshua W.; Carter, Melissa D.; Perez, Jonas W.; Watson, Caroline M.; Tomcik, Dennis J.; Crenshaw, Michael D.; Brewer, Bobby N.; Riches, James R.; Stubbs, Sarah J.; Read, Robert W.; Evans, Ronald A.; Thomas, Jerry D.; Blake, Thomas A.; Johnson, Rudolph C.
2015-01-01
This work describes a new specific, sensitive, and rapid stable isotope dilution method for the simultaneous detection of the organophosphorus nerve agents (OPNAs) tabun (GA), sarin (GB), soman (GD), cyclosarin (GF), VR, VX, and VM adducts to tyrosine (Tyr). Serum, plasma, and lysed whole blood samples (50 µL) were prepared by protein precipitation followed by digestion with Pronase. Specific Tyr adducts were isolated from the digest by a single solid phase extraction (SPE) step, and the analytes were separated by reversed-phase ultra high performance liquid chromatography (UHPLC) gradient elution in less than 2 min. Detection was performed on a triple quadrupole tandem mass spectrometer using time-triggered selected reaction monitoring (SRM) in positive electrospray ionization (ESI) mode. The calibration range was characterized from 0.100–50.0 ng/mL for GB– and VR– Tyr and 0.250–50.0 ng/mL for GA–, GD–, GF–, and VX/VM–Tyr (R2 ≥ 0.995). Inter- and intra-assay precision had coefficients of variation of ≤17 and ≤10%, respectively, and the measured concentration accuracies of spiked samples were within 15% of the targeted value for multiple spiking levels. The limit of detection was calculated to be 0.097, 0.027, 0.018, 0.074, 0.023, and 0.083 ng/mL for GA–, GB–, GD–, GF–, VR–, and VX/VM–Tyr, respectively. A convenience set of 96 serum samples with no known nerve agent exposure was screened and revealed no baseline values or potential interferences. This method provides a simple and highly specific diagnostic tool that may extend the time postevent that a confirmation of nerve agent exposure can be made with confidence. PMID:25286390
Shao, Feng; Hu, Xiao-Ling; Liu, Xin; Shan, Mang-Ting
2017-07-01
The objective of this study was to investigate the stability of edaravone in dog plasma by using an added antioxidant stabilizer, with an ultimate goal of developing and validating a sensitive, reliable and robust LC-MS-MS method for determination of edaravone in plasma samples. Edaravone was unstable in plasma, but it presented a good stability performance in the plasma with sodium metabisulfite (SMB), an effective antioxidant. The blood sample was collected in the heparinized eppendorf tube containing SMB and plasma sample was deproteinized using acetonitrile containing 20 ng/mL of phenacetin (Internal standard). The chromatographic separation was performed on a Zorbax Extend-C18 analytical column (2.1 mm × 150 mm I.D., particle size 3.5 µm, Agilent Technologies, USA). The mobile phase consisted of 0.1% formic acid in water (v/v) and methanol, and gradient elution was used. The analyte detection was performed on a triple quadrupole tandem mass spectrometer equipped with positive-ion electrospray ionization by multiple reaction ion monitoring mode of the transitions at m/z [M + H]+ 175.1 → 77.1 for edaravone, and m/z [M + H]+ 180.2 → 110.0 for phenacetin. The linearity of this method was within the concentration range of 10-1000 ng/mL for edaravone in dog plasma. The lower limit of quantification was 10 ng/mL. The relative standard deviations of intra- and inter-precision were <10%. This method was successfully employed in the pharmacokinetics evaluation of edaravone in beagle dogs after intravenous administration. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Defaix, Celine; Solgadi, Audrey; Pham, Thu Ha; Gardier, Alain M; Chaminade, Pierre; Tritschler, Laurent
2018-04-15
In vivo measurement of multiple neurotransmitters is highly interesting but remains challenging in the field of neuroscience. GABA and l-glutamic acid are the major inhibitory and excitatory neurotransmitters, respectively, in the central nervous system, and their changes are related to a variety of diseases such as anxiety and major depressive disorder. This study described a simple method allowing the simultaneous LC-MS/MS quantification of l-glutamic acid, glutamine and GABA. Analytes were acquired from samples of the prefrontal cortex by microdialysis technique in freely moving mice. The chromatographic separation was performed by hydrophilic interaction liquid chromatography (HILIC) with a core-shell ammonium-sulfonic acid modified silica column using a gradient elution with mobile phases consisting of a 25 mM pH 3.5 ammonium formate buffer and acetonitrile. The detection of l-glutamic acid, glutamine and GABA, as well as the internal standards [d6]-GABA and [d5]-glutamate was performed on a triple quadrupole mass spectrometer in positive electrospray ionization and multiple reaction monitoring mode. The limit of quantification was 0.63 ng/ml for GABA, 1.25 ng/ml for l-glutamic acid and 3.15 ng/ml for glutamine, and the intra-day and inter-day accuracy and precision have been assessed for the three analytes. Therefore, the physiological relevance of the method was successfully applied for the determination of basal extracellular levels and potassium-evoked release of these neuroactive substances in the prefrontal cortex in adult awake C57BL/6 mice. Copyright © 2018 Elsevier B.V. All rights reserved.
Masters, Andrea R; McCoy, Michael; Jones, David R; Desta, Zeruesenay
2016-03-15
Bupropion metabolites formed via oxidation and reduction exhibit pharmacological activity, but little is known regarding their stereoselective disposition. A novel stereoselective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed to separate and quantify enantiomers of bupropion, 4-hydroxybupropion, and erythro- and threo-dihydrobupropion. Liquid-liquid extraction was implemented to extract all analytes from 50 μL human plasma. Acetaminophen (APAP) was used as an internal standard. The analytes were separated on a Lux 3 μ Cellulose-3 250×4.6 mm column by methanol: acetonitrile: ammonium bicarbonate: ammonium hydroxide gradient elution and monitored using an ABSciex 5500 QTRAP triple-quadrupole mass spectrometer equipped with electrospray ionization probe in positive mode. Extraction efficiency for all analytes was ≥70%. The stability at a single non-extracted concentration for over 48 h at ambient temperature resulted in less than 9.8% variability for all analytes. The limit of quantification (LOQ) for enantiomers of bupropion and 4-hydroxybupropion was 0.3 ng/mL, while the LOQ for enantiomers of erythro- and threo-hydrobupropion was 0.15 ng/mL. The intra-day precision and accuracy estimates for enantiomers of bupropion and its metabolites ranged from 3.4% to 15.4% and from 80.6% to 97.8%, respectively, while the inter-day precision and accuracy ranged from 6.1% to 19.9% and from 88.5% to 99.9%, respectively. The current method was successfully implemented to determine the stereoselective pharmacokinetics of bupropion and its metabolites in 3 healthy volunteers administered a single 100mg oral dose of racemic bupropion. This novel, accurate, and precise HPLC-MS/MS method should enhance further research into bupropion stereoselective metabolism and drug interactions. Copyright © 2016 Elsevier B.V. All rights reserved.
Li, Guofei; Cai, Cuifang; Ren, Tianyang; Tang, Xing
2014-01-01
With the purpose to carry out the pharmacokinetic studies of 10-hydroxy camptothecin (10-HCPT) and hydroxyethyl starch (10-HCPT-HES) conjugate, an ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method has been developed and validated. The analytes, 10-HCPT and the internal standard, Diphenhydramine hydrochloride were extracted with ethyl acetate-isopropanol (95:5, v/v) and separated on an ACQUITY UPLC™ BEH C18 column using a mobile phase composed of acetonitrile and water (containing 0.1% formic acid) with a linear gradient program. With positive ion electrospray ionization (ESI), the analytes were monitored on a triple quadrupole mass spectrometer in the multiple reaction monitoring (MRM) mode. Linear calibration curves were obtained over the concentration ranges of 0.5-2500ng/mL. The intra- and inter-day precisions were less than 9.8% and 10.8%, respectively. The accuracy was within 12.1%. The mean recoveries of 10-HCPT at three concentrations of 2.5, 100, 2000ng/mL were higher than 87.2%. Commercial 10-HCPT injection and 10-HCPT-HES conjugate were administered intravenously at an equal dose of 10-HCPT at 0.5mg/kg. The biological half-life of conjugate was increased significantly from 10min to 3.15h and the bioavailability was 40 times higher than 10-HCPT injection. Consequently, the proposed UPLC-ESI-MS/MS method was proved to be sensitive, specific and reliable to analyze 10-HCPT in biological samples; 10-HCPT and HES conjugate is a promising strategy for delivery of 10-HCPT with prolonged half time and improved bioavailability. Copyright © 2013 Elsevier B.V. All rights reserved.
Socas-Rodríguez, Bárbara; Lanková, Darina; Urbancová, Kateřina; Krtková, Veronika; Hernández-Borges, Javier; Rodríguez-Delgado, Miguel Ángel; Pulkrabová, Jana; Hajšlová, Jana
2017-07-01
Within this study, a new method enabling monitoring of various estrogenic substances potentially occurring in milk and dairy products was proposed. Groups of compounds fairly differing in physico-chemical properties and biological activity were analyzed: four natural estrogens, four synthetic estrogens, five mycoestrogens, and nine phytoestrogens. Since they may pass into milk mainly in glucuronated and sulfated forms, an enzymatic hydrolysis was involved prior to the extraction based on the QuEChERS methodology. For the purification of the organic extract, a dispersive solid-phase extraction (d-SPE) with sorbent C18 was applied. The final analysis was performed by ultra-high-performance liquid chromatography (UHPLC) coupled with triple quadrupole tandem mass spectrometry (MS/MS). Method recovery ranged from 70 to 120% with a relative standard deviation (RSD) value lower than 20% and limits of quantification (LOQs) in the range of 0.02-0.60 μg/L (0.2-6.0 μg/kg dry weight) and 0.02-0.90 μg/kg (0.2-6.0 μg/kg dry weight) for milk and yogurt, respectively. The new procedure was applied for the investigation of estrogenic compounds in 11 milk samples and 13 yogurt samples from a Czech retail market. Mainly phytoestrogens were found in the studied samples. The most abundant compounds were equol and enterolactone representing 40-90% of all estrogens. The total content of phytoestrogens (free and bound) was in the range of 149-3870 μg/kg dry weight. This amount is approximately 20 times higher compared to non-bound estrogens.
Bernhardt, Katrin; Valenta, Hana; Kersten, Susanne; Humpf, Hans-Ulrich; Dänicke, Sven
2016-05-01
A sensitive method for the simultaneous determination of T-2 toxin, HT-2 toxin, neosolaniol, T-2 triol, and T-2 tetraol in layer feed using high-performance liquid chromatography coupled to triple quadrupole mass spectrometry in the positive ionization mode (LC-ESI-MS/MS) is described. Two fast and easy clean-up methods-with BondElut Mycotoxin and MycoSep 227 columns, respectively-were tested. The separation of the toxins was conducted on a Pursuit XRs Ultra 2.8 HPLC column using 0.13 mM ammonium acetate as eluent A and methanol as eluent B. Detection of the mycotoxins was carried out in the multiple reaction monitoring (MRM) mode using ammonium adducts as precursor ions. Quantification of all analytes was performed with d3-T-2 toxin as an internal standard. The clean-up method with MycoSep 227 columns gave slightly better results for layer feed compared to the method using BondElut Mycotoxin columns (MycoSep 227: recovery between 50 and 63%, BondElut Mycotoxin: recovery between 32 and 67%) and was therefore chosen as the final method. The limits of detection ranged between 0.9 and 7.5 ng/g depending on the mycotoxin. The method was developed for the analysis of layer feed used at carry-over experiments with T-2 toxin in laying hens. For carry-over experiments, it is necessary that the method includes not only T-2 toxin but also the potential metabolites in animal tissues HT-2 toxin, neosolaniol, T-2 triol, and T-2 tetraol which could naturally occur in cereals used as feed stuff as well.
Further evidence for GHB naturally occurring in common non-alcoholic beverages.
Elliott, Simon P; Fais, Paolo
2017-08-01
GHB has been implicated in many cases of suspected surreptitious administration with the purpose of increasing victim vulnerability to sexual assault. Low amounts of endogenous (or naturally occurring) GHB, which do not reach pharmacologically active levels, have been detected in alcoholic and non-alcoholic beverages. Due to the continued requirement to obtain data on the presence of endogenous GHB in various beverage types, GHB concentrations were measured in a series of non-alcoholic beverages. Tonic water and lemon flavoured tonic water beverages were analysed at 0, 24 and 96h after the bottle opening using gas chromatography coupled to tandem mass spectrometry (GC-MS/MS) on an Agilent 6890/7000C Triple Quadrupole. GHB was detected in all beverages at very low amounts ranging from 89 to 145ng/mL (0.089-0.145mg/L) and did not demonstrate a general trend of variation for concentration along the tested time span (96h). The presented data provide additional evidence for the endogenous nature of GHB in non-alcoholic beverages at very low concentrations, which are many orders of magnitude lower than those described to produce any pharmacological effect on the subject. However, when considering a case of alleged drug-facilitated sexual assault, a low level of GHB detected in a drink may be related both to a surreptitiously GHB administration with subsequent dilution for concealment or to the presence of endogenous GHB. On this basis, a comprehensive analysis of all the available information, including circumstantial data demonstrating possible attempts to conceal GHB administration and an assessment of levels of endogenous GHB in the suspected beverage type, is of the utmost importance for a proper interpretation of the toxicological results. Copyright © 2017 Elsevier B.V. All rights reserved.
Tölgyesi, Ádám; Stroka, Joerg; Tamosiunas, Vytautas; Zwickel, Theresa
2015-01-01
Alternaria toxins and citrinin are mycotoxins produced by fungi growing on different raw materials and agricultural commodities. Maximum levels of these toxins in foods are currently under consideration by the European Commission as a risk management measure. In this study, a new quantitative method is described for the determination of five Alternaria toxins and citrinin in tomato and tomato juice samples based on LC-MS/MS detection. Samples were extracted with pure methanol, followed by a derivatisation step with 2,4-dinitrophenylhydrazine to improve the determination of tenuazonic acid and to decrease the wide polarity difference between the compounds of interest. Samples were purified on hydrophilic-modified styrene polymer solid-phase extraction cartridges. High-performance liquid chromatographic columns packed with different core–shell materials were tested for the separation of toxins and a C-18 phase was in the final method applied to achieve sufficient separation of all relevant analytes. A key element of this approach was to prove successful transferability of the method to three different triple quadrupole mass spectrometers. A full single laboratory method validation was performed on two LC-MS/MS systems and performance characteristics met the predefined requirements. Moreover, the method was used in an international proficiency test and the satisfactory z-scores obtained (−0.1 to 0.8 in tomato juice samples) demonstrated the reliability of the approach described. The method will be validated in an inter-laboratory collaborative study and if the criteria for method precision are met, the method will be proposed as a new Work Item to the European Committee for Standardisation. PMID:26212568
Crow, Brian S; Pantazides, Brooke G; Quiñones-González, Jennifer; Garton, Joshua W; Carter, Melissa D; Perez, Jonas W; Watson, Caroline M; Tomcik, Dennis J; Crenshaw, Michael D; Brewer, Bobby N; Riches, James R; Stubbs, Sarah J; Read, Robert W; Evans, Ronald A; Thomas, Jerry D; Blake, Thomas A; Johnson, Rudolph C
2014-10-21
This work describes a new specific, sensitive, and rapid stable isotope dilution method for the simultaneous detection of the organophosphorus nerve agents (OPNAs) tabun (GA), sarin (GB), soman (GD), cyclosarin (GF), VR, VX, and VM adducts to tyrosine (Tyr). Serum, plasma, and lysed whole blood samples (50 μL) were prepared by protein precipitation followed by digestion with Pronase. Specific Tyr adducts were isolated from the digest by a single solid phase extraction (SPE) step, and the analytes were separated by reversed-phase ultra high performance liquid chromatography (UHPLC) gradient elution in less than 2 min. Detection was performed on a triple quadrupole tandem mass spectrometer using time-triggered selected reaction monitoring (SRM) in positive electrospray ionization (ESI) mode. The calibration range was characterized from 0.100-50.0 ng/mL for GB- and VR-Tyr and 0.250-50.0 ng/mL for GA-, GD-, GF-, and VX/VM-Tyr (R(2) ≥ 0.995). Inter- and intra-assay precision had coefficients of variation of ≤17 and ≤10%, respectively, and the measured concentration accuracies of spiked samples were within 15% of the targeted value for multiple spiking levels. The limit of detection was calculated to be 0.097, 0.027, 0.018, 0.074, 0.023, and 0.083 ng/mL for GA-, GB-, GD-, GF-, VR-, and VX/VM-Tyr, respectively. A convenience set of 96 serum samples with no known nerve agent exposure was screened and revealed no baseline values or potential interferences. This method provides a simple and highly specific diagnostic tool that may extend the time postevent that a confirmation of nerve agent exposure can be made with confidence.
Swortwood, Madeleine J; Boland, Diane M; DeCaprio, Anthony P
2013-02-01
Recently, clandestine drug lab operators have attempted to bypass controlled substances laws and regulations with "designer" compounds chemically and pharmacologically similar to controlled substances. For example, "bath salts" have erupted onto the scene as "legal highs" containing cathinone analogs that have produced severe side effects in users worldwide. These products have sparked concern among law enforcement agencies, and emergency bans have been placed on the sale of such items. Despite the increasing number of designer drugs available, there are few comprehensive screening techniques for their detection and quantification in biological specimens. The liquid chromatography triple quadrupole tandem mass spectrometry (LC-QQQ-MS/MS) method presented here encompasses over thirty important compounds within the phenethylamine, tryptamine, and piperazine designer drug classes. Analytes were determined by LC-QQQ-MS/MS in the multiple-reaction monitoring mode after mixed-mode solid-phase extraction. The bioanalytical method was fully validated according to recommended international guidelines. The assay was selective for all analytes with acceptable accuracy and precision. Limits of quantification were in the range of 1-10 ng/mL for each compound with limits of detection near 10 pg/mL. In order to evaluate its applicability in a forensic toxicological setting, the validated method was used to analyze post-mortem specimens from two cases that were suspected of containing designer drugs. The method was able to identify and quantify seven of these compounds at concentrations as low as 11 ng/mL. The method should have wide applicability for rapid screening of important new drugs of abuse at high sensitivity in both post- and ante-mortem forensic analysis.
Cheng, Yung-Yi; Tsai, Tung-Hu
2016-06-05
Rhodamine B is an illegal and potentially carcinogenic food dye. The aim of this study was to develop a convenient, rapid, and sensitive UHPLC-MS/MS method for pharmacokinetic studies in rats. Rat plasma samples were deproteinized with acetonitrile and separated by UHPLC on a reverse-phase C18e column (100mm×2.1mm, 2μm) using a mobile phase consisting of methanol-5mM ammonium acetate (90:10, v/v). Detection was performed using a triple quadrupole tandem mass spectrometer in the selected reaction monitoring mode at [M](+) ion m/z 443.39→399.28 for rhodamine B and [M+H](+) ion m/z 253.17→238.02 for 5-methoxyflavone as the internal standard. This method was specific and produced linear results over a concentration range of 0.5-100ng/mL, with a lower limit of quantitation of 0.5ng/mL. All validation parameters, including the inter-day, intra-day, matrix effect, recovery, and stability in rat plasma, were acceptable according to the biological method validation guidelines developed by the FDA (2001). This method was successfully applied to a pharmacokinetic study in rats; oral administration of 1mg/kg of rhodamine B yielded a time to maximum concentration (Tmax) of 1.3±0.4h and an elimination half-life of 8.8±1.4h, with a clearance of 229.7±19.4mL/h/kg. These pharmacokinetic results provide a constructive contribution to our understanding of the absorption mechanism of rhodamine B and support additional food safety evaluations. Copyright © 2016 Elsevier B.V. All rights reserved.
Badawi, Nora; Simonsen, Kirsten Wiese; Steentoft, Anni; Bernhoft, Inger Marie; Linnet, Kristian
2009-11-01
The European DRUID (Driving under the Influence of Drugs, Alcohol And Medicines) project calls for analysis of oral fluid (OF) samples, collected randomly and anonymously at the roadside from drivers in Denmark throughout 2008-2009. To analyze these samples we developed an ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for detection of 29 drugs and illicit compounds in OF. The drugs detected were opioids, amphetamines, cocaine, benzodiazepines, and Delta-9-tetrahydrocannabinol. Solid-phase extraction was performed with a Gilson ASPEC XL4 system equipped with Bond Elut Certify sample cartridges. OF samples (200 mg) diluted with 5 mL of ammonium acetate/methanol (vol/vol 90:10) buffer were applied to the columns and eluted with 3 mL of acetonitrile with aqueous ammonium hydroxide. Target drugs were quantified by use of a Waters ACQUITY UPLC system coupled to a Waters Quattro Premier XE triple quadrupole (positive electrospray ionization mode, multiple reaction monitoring mode). Extraction recoveries were 36%-114% for all analytes, including Delta-9-tetrahydrocannabinol and benzoylecgonine. The lower limit of quantification was 0.5 mug/kg for all analytes. Total imprecision (CV) was 5.9%-19.4%. With the use of deuterated internal standards for most compounds, the performance of the method was not influenced by matrix effects. A preliminary account of OF samples collected at the roadside showed the presence of amphetamine, cocaine, codeine, Delta-9-tetrahydrocannabinol, tramadol, and zopiclone. The UPLC-MS/MS method makes it possible to detect all 29 analytes in 1 chromatographic run (15 min), including Delta-9-tetrahydrocannabinol and benzoylecgonine, which previously have been difficult to incorporate into multicomponent methods.
Simultaneous quantitation of multiple contraceptive hormones in human serum by LC-MS/MS.
Blue, Steven W; Winchell, Andrea J; Kaucher, Amy V; Lieberman, Rachel A; Gilles, Christopher T; Pyra, Maria N; Heffron, Renee; Hou, Xuanlin; Coombs, Robert W; Nanda, Kavita; Davis, Nicole L; Kourtis, Athena P; Herbeck, Joshua T; Baeten, Jared M; Lingappa, Jairam R; Erikson, David W
2018-04-01
The objective was to develop a method to simultaneously quantify five commonly used hormonal contraceptives (HCs) and two endogenous sex steroids by liquid chromatography-tandem triple quadrupole mass spectrometry (LC-MS/MS) and apply this method to human serum samples. We developed a method to simultaneously analyze ethinyl estradiol (EE2), etonogestrel (ENG), levonorgestrel (LNG), medroxyprogesterone acetate (MPA) and norethisterone (NET), along with estradiol (E2) and progesterone (P4), in human serum for a Shimadzu Nexera-LCMS-8050 LC-MS/MS platform. We analyzed serum collected from women self-reporting use of oral contraceptives, contraceptive implants or injectable contraceptives (n=14) and normally cycling women using no HC (n=15) as well as pooled samples from women administered various HCs (ENG, n=6; LNG, n=14; MPA, n=7; NET, n=5). Limits of quantitation were 0.010ng/mL for E2, EE2 and P4; 0.020ng/mL for ENG, LNG and MPA; and 0.040ng/mL for NET. Precisions for all assays, as indicated by coefficient of variation, were less than or equal to 12.1%. Accuracies for all assays were in the range of 95%-108%. Endogenous hormone values obtained from analysis of human serum samples are in agreement with levels previously reported in the literature for normally cycling women as well as for women taking the appropriate HC. We have developed a robust, accurate and sensitive method for simultaneously analyzing commonly used contraceptive steroids and endogenous sex steroids in human serum. This analytical method can be used for quantitating contraceptive steroid levels in women for monitoring systemic exposure to determine drug interactions, nonadherence, misreporting and proper dosing. Copyright © 2018 Elsevier Inc. All rights reserved.
Man, Zhengyin; Wang, Quanlin; Li, Hesheng; Zhang, Aizhi; Shen, Jian
2015-03-01
A comprehensive analytical method based on ultra-performance liquid chromatography coupled with triple quadrupole mass spectrometry (UPLC-MS/MS) has been developed for the simultaneous determination of 33 primary aromatic amines (PAAs) in polystyrene (PS) and polyethylene (PE) masterbatches for foods. The PS masterbatches were dissolved with dichloromethane, and methanol was added to precipitate after extraction by ultrasound extraction. Then the extract was purified by passing through a carbon graphite solid phase extraction column. The PE masterbatches were swelled and extracted with dichloromethane by ultrasound. The purified PS solution and PE extract were concentrated, and diluted to 2 mL with methanol-water (1:9, v/v), and filtered through the membranes of 0.22 µm before UPLC-MS/MS analysis. The analytes were separated on a BEH Phenyl column (100 mm x 2.1 mm, 1.7 µm), eluted by gradient with 0.07% (v/v) formic acid in methanol-water (1:9, v/v). The PAAs were detected by UPLC-MS/MS under multiple reaction monitoring (MRM) mode and quantified by the internal standard method. The separation conditions, fragment voltages and collision energies were optimized. The impacts of extraction times, extraction solvents and concentration methods on recoveries were studied. The limits of detection for the 33 primary aromatic amines were 6-10 µg/kg, and the limits of quantitation were 20-30 µg/kg. The mean recoveries of the two different masterbatch products at three spiked levels of 20, 100, 200 µg/kg were 61.3%-119.8%, and the relative standard deviations were 1.4%-14.8%. The experimental results indicated that the method is simple, rapid, sensitive, accurate, and can meet the related requirements for determination.
van de Merbel, Nico C; Walland, Peter; Tiensuu, Mikael; Sennbro, Carl J
2014-06-15
Tasquinimod is an anti-tumor drug that is currently in clinical development for the treatment of solid cancers. After oral administration, tasquinimod and a number of its metabolites are excreted in the urine. The quantitative determination of tasquinimod in urine is challenging because of the required sensitivity (down to 0.1nM or 40pg/mL), the highly variable nature of this biological matrix and the presence of potentially unstable metabolites, which may convert back to the parent drug. In this article, an LC-MS/MS method is described for the determination of tasquinimod in human urine in the concentration range 0.1-200nM. Liquid-liquid extraction with n-chlorobutane was used to extract tasquinimod from 100μL human urine and to remove interfering endogenous urinary constituents. Reversed-phase liquid chromatography coupled to a triple quadrupole mass spectrometer equipped with an ESI source was used for quantification of tasquinimod in a 2.5-min run. A stable-isotope labeled internal standard was used for response normalization. The intra- and inter-day coefficients of variation (precision) as well as the bias (accuracy) of the method were below 7%. Although considerable conversion of conjugated tasquinimod metabolites back to parent drug was observed when incurred samples were stored at 37°C for a prolonged time, tasquinimod as well as its metabolites were sufficiently stable under all relevant sampling, storage and analysis conditions. The method was successfully applied to determine the urinary excretion of tasquinimod in healthy volunteers and patients with renal impairment after a 0.5-mg oral dose. Copyright © 2014 Elsevier B.V. All rights reserved.
Douglas, David; Banaszewski, Katie; Juskelis, Rima; Al-Taher, Fadwa; Chen, Yang; Cappozzo, Jack; McRobbie, Lindsay; Salter, Robert S
2012-07-01
β-Lactam antibiotics are the most commonly used drugs on dairy farms. β-Lactam residues in milk are kept out of the human milk supply with good agricultural practices and mandatory truck screening performed by the dairy industry under Appendix N of the Pasteurized Milk Ordinance. Flunixin, a nonsteroidal and anti-inflammatory drug, appears in dairy cattle tissue residues with a frequency similar to the occurrence of penicillin G. This creates concern that flunixin residues could be in milk and would go undetected under current milk screening programs. A single test that combines mandatory β-lactam screening with voluntary flunixin screening is an economical approach for monitoring and controlling for potential flunixin or 5-hydroxyflunixin, the primary flunixin metabolite marker in milk. The objective of this study was to validate a β-lactam and flunixin rapid lateral flow test (LFT) and compare the results obtained with a liquid chromatography-triple quadrupole tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of flunixin and 5-hydroxyflunixin in raw milk with a limit of detection of , 1 ppb, equivalent to 1 ng/ml. Using the LFT, three combined manufactured lots of test strips detected penicillin G at 2.0 ppb, ampicillin at 6.8 ppb, amoxicillin at 5.9 ppb, cephapirin at 13.4 ppb, ceftiofur (total metabolites) at 63 ppb, and 5-hydroxyflunixin at 1.9 ppb at least 90% of the time with 95% confidence. The LFT also detected incurred flunixin milk samples that were analyzed with the LC-MS/MS and diluted to tolerance in raw milk. The detection levels for the LFT are lower than the U.S. safe levels or tolerances and qualify the test to be used in compliance with U.S. milk screening programs.