Sample records for tank cable tray

  1. Aeroelastic Response and Protection of Space Shuttle External Tank Cable Trays

    NASA Technical Reports Server (NTRS)

    Edwards, John W.; Keller, Donald F.; Schuster, David M.; Piatak, David J.; Rausch, Russ D.; Bartels, Robert E.; Ivanco, Thomas G.; Cole, Stanley R.; Spain, Charles V.

    2005-01-01

    Sections of the Space Shuttle External Tank Liquid Oxygen (LO2) and Liquid Hydrogen (LH2) cable trays are shielded from potentially damaging airloads with foam Protuberance Aerodynamic Load (PAL) Ramps. Flight standard design LO2 and LH2 cable tray sections were tested with and without PAL Ramp models in the United States Air Force Arnold Engineering Development Center s (AEDC) 16T transonic wind tunnel to obtain experimental data on the aeroelastic stability and response characteristics of the trays and as part of the larger effort to determine whether the PAL ramps can be safely modified or removed. Computational Fluid Dynamic simulations of the full-stack shuttle launch configuration were used to investigate the flow characeristics around and under the cable trays without the protective PAL ramps and to define maximum crossflow Mach numbers and dynamic pressures experienced during launch. These crossflow conditions were used to establish wind tunnel test conditions which also included conservative margins. For all of the conditions and configurations tested, no aeroelastic instabilities or unacceptable dynamic response levels were encountered and no visible structural damage was experienced by any of the tested cable tray sections. Based upon this aeroelastic characterization test, three potentially acceptable alternatives are available for the LO2 cable tray PAL Ramps: Mini-Ramps, Tray Fences, or No Ramps. All configurations were tested to maximum conditions, except the LH2 trays at -15 deg. crossflow angle. This exception is the only caveat preventing the proposal of acceptable alternative configurations for the LH2 trays as well. Structural assessment of all tray loads and tray response measurements from launches following the Shuttle Return To Flight with the existing PAL Ramps will determine the acceptability of these PAL Ramp alternatives.

  2. Vibration Analysis of the Space Shuttle External Tank Cable Tray Flight Data With and Without PAL Ramp

    NASA Technical Reports Server (NTRS)

    Walker, Bruce E.; Panda, Jayanta; Sutliff, Daniel L.

    2008-01-01

    External Tank Cable Tray vibration data for three successive Space Shuttle flights were analyzed to assess response to buffet and the effect of removal of the Protuberance Air Loads (PAL) ramp. Waveform integration, spectral analysis, cross-correlation analysis and wavelet analysis were employed to estimate vibration modes and temporal development of vibration motion from a sparse array of accelerometers and an on-board system that acquired 16 channels of data for approximately the first 2 min of each flight. The flight data indicated that PAL ramp removal had minimal effect on the fluctuating loads on the cable tray. The measured vibration frequencies and modes agreed well with predicted structural response.

  3. Vibration Analysis of the Space Shuttle External Tank Cable Tray Flight Data with and without PAL Ramp

    NASA Technical Reports Server (NTRS)

    Walker, B. E.; Panda, B. E.; Sutliff, D. L.

    2008-01-01

    External Tank Cable Tray vibration data for three successive Space Shuttle flights were analyzed to assess response to buffet and the effect of removal of the Protuberance Air Loads (PAL) ramp. Waveform integration, spectral analysis, cross-correlation analysis and wavelet analysis were employed to estimate vibration modes and temporal development of vibration motion from a sparse array of accelerometers and an on-board system that acquired 16 channels of data for approximately the first two minutes of each flight. The flight data indicated that PAL ramp removal had minimal effect on the fluctuating loads on the cable tray. The measured vibration frequencies and modes agreed well with predicted structural response.

  4. Overhead tray for cable test system

    NASA Technical Reports Server (NTRS)

    Saltz, K. T.

    1976-01-01

    System consists of overhead slotted tray, series of compatible adapter cables, and automatic test set which consists of control console and cable-switching console. System reduces hookup time and also reduces cost of fabricating and storing test cables.

  5. 5. VIEW OF CABLE SHED AND CABLE TRAY EMANATING FROM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. VIEW OF CABLE SHED AND CABLE TRAY EMANATING FROM SOUTH FACE OF LAUNCH OPERATIONS BUILDING. MICROWAVE DISH IN FOREGROUND. METEOROLOGICAL TOWER IN BACKGROUND. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  6. 106. INTERIOR OF CABLE TRAY TUNNEL, FROM LANDLINE INSTRUMENTATION ROOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    106. INTERIOR OF CABLE TRAY TUNNEL, FROM LANDLINE INSTRUMENTATION ROOM (106), LSB (BLDG. 770), TOWARDS CABLE TRAY SHED - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  7. 4. VIEW OF CABLE SHED AND CABLE TRAY EMANATING FROM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. VIEW OF CABLE SHED AND CABLE TRAY EMANATING FROM NORTH FACE OF LAUNCH OPERATIONS BUILDING. TOPS OF BUNKER PERISCOPE AND FLAGPOLE ON ROOF OF LAUNCH OPERATIONS BUILDING IN BACKGROUND - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  8. 105. CABLE TRAY TUNNEL ENTRANCE TO LSB (BLDG. 770) AT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    105. CABLE TRAY TUNNEL ENTRANCE TO LSB (BLDG. 770) AT SOUTH END OF LANDLINE INSTRUMENTATION ROOM - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  9. 29. VIEW OF 4TH FLOOR'S TELEPHONE RACKS WITH CABLE TRAYS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. VIEW OF 4TH FLOOR'S TELEPHONE RACKS WITH CABLE TRAYS ABOVE. THESE ARE NEWER APPARATUS AND NOT ORIGINAL. - Pacific Telephone & Telegraph Company Building, 1519 Franklin Street, Oakland, Alameda County, CA

  10. 75 FR 61521 - NUREG/CR-7010, Cable Heat Release, Ignition, and Spread in Tray Installations During Fire...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-05

    ... tray configurations. The experiments conducted range from micro-scale, in which very small (5 mg... burned under a large oxygen- depletion calorimeter. Other experiments include cone calorimetry, smoke and... tray of cables underneath a bank of radiant panels. The results of the small-scale experiments are to...

  11. Results of Experimental Investigations to Determine External Tank Protuberance Loads Using a 0.03-Scale Model of the Space Shuttle Launch Configuration (Model 47-OTS) in the NASA/ARC Unitary Plan Wind Tunnel, Volume 2

    NASA Technical Reports Server (NTRS)

    Houlihan, S. R.

    1992-01-01

    Data were obtained on a 3-percent model of the Space Shuttle launch vehicle in the NASA/Ames Research Center 11x11-foot and 9x7-foot Unitary Plan Wind Tunnels. This test series has been identified as IA19OA/B and was conducted from 7 Feb. 1980 to 19 Feb. 1980 (IA19OA) and from 17 March 1980 to 19 March 1980 and from 8 May 1980 to 30 May 1980 (IA19OB). The primary test objective was to obtain structural loads on the following external tank protuberances: (1) LO2 feedline; (2) GO2 pressure line; (3) LO2 antigeyser line; (4) GH2 pressure line; (5) LH2 tank cable tray; (6) LO2 tank cable tray; (7) Bipod; (8) ET/SRB cable tray; and (9) Crossbeam/Orbiter cable tray. To fulfill these objectives the following steps were taken: Eight 3-component balances were used to measure forces on various sections of 1 thru 6 above; 315 pressure orifices were distributed over all 9 above items. The LO2 feedline was instrumented with 96 pressure taps and was rotated to four positions to yield 384 pressure measurements. The LO2 antigeyser line was instrumented with 64 pressure taps and was rotated to two positions to yield 128 pressure measurements; Three Chrysler miniature flow direction probes were mounted on a traversing mechanism on the tank upper surface centerline to obtain flow field data between the forward and aft attach structures; and Schlieren photographs and ultraviolet flow photographs were taken at all test conditions. Data from each of the four test phases are presented.

  12. Results of experimental investigations to determine external tank protuberance loads using a 0.03-scale model of the Space Shuttle launch configuration (model 47-OTS) in the NASA/ARC unitary plan wind tunnel, volume 1

    NASA Technical Reports Server (NTRS)

    Houlihan, S. R.

    1992-01-01

    Data were obtained on a 3-percent model of the Space Shuttle launch vehicle in the NASA/Ames Research Center 11x11-foot and 9x7-foot Unitary Plan Wind Tunnels. This test series has been identified as IA190A/B and was conducted from 7 Feb. 1980 to 19 Feb. 1980 (IA190A) and from 17 March 1980 to 19 March 1980 and from 8 May 1980 to 30 May 1980 (IA190B). The primary test objective was to obtain structural loads on the following external tank protuberances: (1) LO2 feedline, (2) GO2 pressure line, (3) LO2 antigeyser line, (4) GH2 pressure line, (5) LH2 tank cable tray, (6) LO2 tank cable tray, (7) Bipod, (8) ET/SRB cable tray, and (9) Crossbeam/Orbiter cable tray. To fulfill these objectives the following steps were taken: (1) Eight 3-component balances were used to measure forces on various sections of 1 thru 6 above. (2) 315 pressure orifices were distributed over all 9 above items. The LO2 feedline was instrumented with 96 pressure taps and was rotated to four positions to yield 384 pressure measurements. The LO2 antigeyser line was instrumented with 64 pressure taps and was rotated to two positions to yield 128 pressure measurements. (3) Three Chrysler miniature flow direction probes were mounted on a traversing mechanism on the tank upper surface centerline to obtain flow field data between the forward and aft attach structures. (4) Schlieren photographs and ultraviolet flow photographs were taken at all test conditions. Data from each of the four test phases are presented.

  13. 105. VIEW NORTH FROM SLC3W CABLE TUNNEL INTO CABLE VAULT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    105. VIEW NORTH FROM SLC-3W CABLE TUNNEL INTO CABLE VAULT AND SLC-3E CABLE TUNNEL. NOTE WOODEN PLANKING ON FLOOR OF TUNNEL AND CABLE TRAYS LINING TUNNEL WALLS. STAIRS ON EAST WALL OF CABLE VAULT LEAD INTO LANDLINE INSTRUMENTATION ROOM. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  14. 6. CONSTRUCTION PROGRESS VIEW (EXTERIOR) OF TANK, CABLE CHASE, AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. CONSTRUCTION PROGRESS VIEW (EXTERIOR) OF TANK, CABLE CHASE, AND MOUNDED BUNKER. CONSTRUCTION WAS 99 PERCENT COMPLETE. CAMERA IS FACING WEST. INEL PHOTO NUMBER 65-5435, TAKEN OCTOBER 20, 1965. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  15. 101. CABLE DISTRIBUTION UNITS, SOUTHEAST SIDE OF LANDLINE INSTRUMENTATION ROOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    101. CABLE DISTRIBUTION UNITS, SOUTHEAST SIDE OF LANDLINE INSTRUMENTATION ROOM (106), LSB (BLDG. 770). NOTE CABLES ENTER CABLE DISTRIBUTION UNITS FROM OVERHEAD CABLE TRAYS. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  16. Comparing surgical trays with redundant instruments with trays with reduced instruments: a cost analysis

    PubMed Central

    John-Baptiste, A.; Sowerby, L.J.; Chin, C.J.; Martin, J.; Rotenberg, B.W.

    2016-01-01

    Background: When prearranged standard surgical trays contain instruments that are repeatedly unused, the redundancy can result in unnecessary health care costs. Our objective was to estimate potential savings by performing an economic evaluation comparing the cost of surgical trays with redundant instruments with surgical trays with reduced instruments ("reduced trays"). Methods: We performed a cost-analysis from the hospital perspective over a 1-year period. Using a mathematical model, we compared the direct costs of trays containing redundant instruments to reduced trays for 5 otolaryngology procedures. We incorporated data from several sources including local hospital data on surgical volume, the number of instruments on redundant and reduced trays, wages of personnel and time required to pack instruments. From the literature, we incorporated instrument depreciation costs and the time required to decontaminate an instrument. We performed 1-way sensitivity analyses on all variables, including surgical volume. Costs were estimated in 2013 Canadian dollars. Results: The cost of redundant trays was $21 806 and the cost of reduced trays was $8803, for a 1-year cost saving of $13 003. In sensitivity analyses, cost savings ranged from $3262 to $21 395, based on the surgical volume at the institution. Variation in surgical volume resulted in a wider range of estimates, with a minimum of $3253 for low-volume to a maximum of $52 012 for high-volume institutions. Interpretation: Our study suggests moderate savings may be achieved by reducing surgical tray redundancy and, if applied to other surgical specialties, may result in savings to Canadian health care systems. PMID:27975045

  17. Comparing surgical trays with redundant instruments with trays with reduced instruments: a cost analysis.

    PubMed

    John-Baptiste, A; Sowerby, L J; Chin, C J; Martin, J; Rotenberg, B W

    2016-01-01

    When prearranged standard surgical trays contain instruments that are repeatedly unused, the redundancy can result in unnecessary health care costs. Our objective was to estimate potential savings by performing an economic evaluation comparing the cost of surgical trays with redundant instruments with surgical trays with reduced instruments ("reduced trays"). We performed a cost-analysis from the hospital perspective over a 1-year period. Using a mathematical model, we compared the direct costs of trays containing redundant instruments to reduced trays for 5 otolaryngology procedures. We incorporated data from several sources including local hospital data on surgical volume, the number of instruments on redundant and reduced trays, wages of personnel and time required to pack instruments. From the literature, we incorporated instrument depreciation costs and the time required to decontaminate an instrument. We performed 1-way sensitivity analyses on all variables, including surgical volume. Costs were estimated in 2013 Canadian dollars. The cost of redundant trays was $21 806 and the cost of reduced trays was $8803, for a 1-year cost saving of $13 003. In sensitivity analyses, cost savings ranged from $3262 to $21 395, based on the surgical volume at the institution. Variation in surgical volume resulted in a wider range of estimates, with a minimum of $3253 for low-volume to a maximum of $52 012 for high-volume institutions. Our study suggests moderate savings may be achieved by reducing surgical tray redundancy and, if applied to other surgical specialties, may result in savings to Canadian health care systems.

  18. Drying time of tray adhesive for adequate tensile bond strength between polyvinylsiloxane impression and tray resin material.

    PubMed

    Yi, Myong-Hee; Shim, Joon-Sung; Lee, Keun-Woo; Chung, Moon-Kyu

    2009-07-01

    Use of custom tray and tray adhesive is clinically recommended for elastomeric impression material. However there is not clear mention of drying time of tray adhesive in achieving appropriate bonding strength of tray material and impression material. This study is to investigate an appropriate drying time of tray adhesives by evaluating tensile bonding strength between two types of polyvinylsiloxane impression materials and resin tray, according to various drying time intervals of tray adhesives, and with different manufacturing company combination of impression material and tray adhesive. Adhesives used in this study were Silfix (Dentsply Caulk, Milford, Del, USA) and VPS Tray Adhesive (3M ESPE, Seefeld, Germany) and impression materials were Aquasil Ultra (monophase regular set, Dentsply Caulk, Milford, Del, USA) and Imprint II Garant (regular body, 3M ESPE, Seefeld, Germany). They were used combinations from the same manufacture and exchanged combinations of the two. The drying time was designed to air dry, 5 minutes, 10 minutes, 15 minutes, 20 minutes, and 25 minutes. Total 240 of test specimens were prepared by auto-polymerizing tray material (Instant Tray Mix, Lang, Wheeling, Il, USA) with 10 specimens in each group. The specimens were placed in the Universal Testing machine (Instron, model 3366, Instron Corp, University avenue, Nowood, MA, USA) to perform the tensile test (cross head speed 5 mm/min). The statistically efficient drying time was evaluated through ANOVA and Scheffe test. All the tests were performed at 95% confidence level. The results revealed that at least 10 minutes is needed for Silfix-Aquasil, and 15 minutes for VPS Tray Adhesive-Imprint II, to attain an appropriate tensile bonding strength. VPS Tray Adhesive-Imprint II had a superior tensile bonding strength when compared to Silfix-Aquasil over 15 minutes. Silfix-Aquasil had a superior bonding strength to VPS Tray Adhesive-Aquasil, and VPS Tray Adhesive-Imprint II had a superior tensile

  19. Protein crystal growth tray assembly

    NASA Technical Reports Server (NTRS)

    Carter, Daniel C. (Inventor); Miller, Teresa Y. (Inventor)

    1992-01-01

    A protein crystal growth tray assembly includes a tray that has a plurality of individual crystal growth chambers. Each chamber has a movable pedestal which carries a protein crystal growth compartment at an upper end. The several pedestals for each tray assembly are ganged together for concurrent movement so that the solutions in the various pedestal growth compartments can be separated from the solutions in the tray's growth chambers until the experiment is to be activated.

  20. Comparison of Dimensional Accuracy between Open-Tray and Closed-Tray Implant Impression Technique in 15° Angled Implants

    PubMed Central

    Balouch, F; Jalalian, E; Nikkheslat, M; Ghavamian, R; Toopchi, Sh; Jallalian, F; Jalalian, S

    2013-01-01

    Statement of Problem: Various impression techniques have different effects on the accuracy of final cast dimensions. Meanwhile; there are some controversies about the best technique. Purpose: This study was performed to compare two kinds of implant impression methods (open tray and closed tray) on 15 degree angled implants. Materials and Method: In this experimental study, a steel model with 8 cm in diameter and 3 cm in height were produced with 3 holes devised inside to stabilize 3 implants. The central implant was straight and the other two implants were 15° angled. The two angled implants had 5 cm distance from each other and 3.5 cm from the central implant. Dental stone, high strength (type IV) was used for the main casts. Impression trays were filled with poly ether, and then the two impression techniques (open tray and closed tray) were compared. To evaluate positions of the implants, each cast was analyzed by CMM device in 3 dimensions (x,y,z). Differences in the measurements obtained from final casts and laboratory model were analyzed using t-Test. Results: The obtained results indicated that closed tray impression technique was significantly different in dimensional accuracy when compared with open tray method. Dimensional changes were 129 ± 37μ and 143.5 ± 43.67μ in closed tray and open tray, while coefficient of variation in closed- tray and open tray were reported to be 27.2% and 30.4%, respectively. Conclusion: Closed impression technique had less dimensional changes in comparison with open tray method, so this study suggests that closed tray impression technique is more accurate. PMID:24724130

  1. Flexible Interior-Impression-Molding Tray

    NASA Technical Reports Server (NTRS)

    Anders, Jeffrey E.

    1991-01-01

    Device used inside combustion chamber of complicated shape for nondestructive evaluation of qualities of welds, including such features as offset, warping, misalignment of parts, and dropthrough. Includes flexible polypropylene tray trimmed to fit desired interior surface contour. Two neodymium boron magnets and inflatable bladder attached to tray. Tray and putty inserted in cavity to make mold of interior surface.

  2. Distillation tray structural parameter study: Phase 1

    NASA Technical Reports Server (NTRS)

    Winter, J. Ronald

    1991-01-01

    The purpose here is to identify the structural parameters (plate thickness, liquid level, beam size, number of beams, tray diameter, etc.) that affect the structural integrity of distillation trays in distillation columns. Once the sensitivity of the trays' dynamic response to these parameters has been established, the designer will be able to use this information to prepare more accurate specifications for the construction of new trays. Information is given on both static and dynamic analysis, modal response, and tray failure details.

  3. Influence of Custom Trays, Dual-Arch Passive, Flexed Trays and Viscosities of Elastomeric Impression Materials on Working Dies.

    PubMed

    Arora, Mansi; Kohli, Shivani; Kalsi, Rupali

    2016-05-01

    Dual arch impression technique signifies an essential improvement in fixed prosthodontics and has numerous benefits over conventional impression techniques. The accuracy of working dies fabricated from dual arch impression technique remains in question because there is little information available in the literature. This study was conducted to compare the accuracy of working dies fabricated from impressions made from two different viscosities of impression materials using metal, plastic dual arch trays and custom made acrylic trays. The study samples were grouped into two groups based on the viscosity of impression material used i.e. Group I (monophase), whereas Group II consisted of Dual Mix technique using a combination of light and heavy body material. These were further divided into three subgroups A, B and C depending on the type of impression tray used (metal dual arch tray, plastic dual arch tray and custom made tray). Measurements of the master cast were made using profile projector. Descriptive statistics like mean, Standard Deviation (SD) were calculated for all the groups. One way analysis of variance (ANOVA) was used for multiple group comparisons. A p-value of 0.05 or less was considered statistically significant. The gypsum dies obtained with the three types of impression trays using two groups of impression materials were smaller than the master models in dimensions. The plastic dual arch trays produced dies which were the least accurate of the three groups. There was no significant difference in the die dimensions obtained using the two viscosities of impression materials.

  4. Influence of Custom Trays, Dual-Arch Passive, Flexed Trays and Viscosities of Elastomeric Impression Materials on Working Dies

    PubMed Central

    Kohli, Shivani; Kalsi, Rupali

    2016-01-01

    Introduction Dual arch impression technique signifies an essential improvement in fixed prosthodontics and has numerous benefits over conventional impression techniques. The accuracy of working dies fabricated from dual arch impression technique remains in question because there is little information available in the literature. Aim This study was conducted to compare the accuracy of working dies fabricated from impressions made from two different viscosities of impression materials using metal, plastic dual arch trays and custom made acrylic trays. Materials and Methods The study samples were grouped into two groups based on the viscosity of impression material used i.e. Group I (monophase), whereas Group II consisted of Dual Mix technique using a combination of light and heavy body material. These were further divided into three subgroups A, B and C depending on the type of impression tray used (metal dual arch tray, plastic dual arch tray and custom made tray). Measurements of the master cast were made using profile projector. Descriptive statistics like mean, Standard Deviation (SD) were calculated for all the groups. One way analysis of variance (ANOVA) was used for multiple group comparisons. A p-value of 0.05 or less was considered statistically significant. Results The gypsum dies obtained with the three types of impression trays using two groups of impression materials were smaller than the master models in dimensions. Conclusion The plastic dual arch trays produced dies which were the least accurate of the three groups. There was no significant difference in the die dimensions obtained using the two viscosities of impression materials. PMID:27437342

  5. Develop and Manufacture an airlock sliding tray

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lawton, Cindy M.

    2014-02-26

    The goal of this project is to continue to develop an airlock sliding tray and then partner with an industrial manufacturing company for production. The sliding tray will be easily installed into and removed from most glovebox airlocks in a few minutes. Technical Approach: A prototype of a sliding tray has been developed and tested in the LANL cold lab and 35 trays are presently being built for the plutonium facility (PF-4). The current, recently approved design works for a 14-inch diameter round airlock and has a tray length of approximately 20 inches. The grant will take the already testedmore » and approved round technology and design for the square airlock. These two designs will be suitable for the majority of the existing airlocks in the multitude of DOE facilities. Partnering with an external manufacturer will allow for production of the airlock trays at a much lower cost and increase the availability of the product for all DOE sites. Project duration is estimated to be 12-13 months. Benefits: The purpose of the airlock sliding trays is fourfold: 1) Mitigate risk of rotator cuff injuries, 2) Improve ALARA, 3) Reduce risk of glovebox glove breaches and glove punctures, and 4) Improve worker comfort. I have had the opportunity to visit many other DOE facilities including Savannah, Y-12, ORNL, Sandia, and Livermore for assistance with ergonomic problems and/or injuries. All of these sites would benefit from the airlock sliding tray and I can assume all other DOE facilities with gloveboxes built prior to 1985 could also use the sliding trays.« less

  6. Silver Teflon blanket: LDEF tray C-08

    NASA Technical Reports Server (NTRS)

    Crutcher, E. Russ; Nishimura, L. S.; Warner, K. J.; Wascher, W. W.

    1992-01-01

    A study of the Teflon blanket surface at the edge of tray C-08 illustrates the complexity of the microenvironments on the Long Duration Exposure Facility (LDEF). The distribution of particulate contaminants varied dramatically over a distance of half a centimeter (quarter of an inch) near the edge of the blanket. The geometry and optical effects of the atomic oxygen erosion varied significantly over the few centimeters where the blanket folded over the edge of the tray resulting in a variety of orientations to the atomic oxygen flux. A very complex region of combined mechanical and atomic oxygen damage occurred where the blanket contacted the edge of the tray. A brown film deposit apparently fixed by ultraviolet light traveling by reflection through the Teflon film was conspicuous beyond the tray contract zone. Chemical and structural analysis of the surface of the brown film and beyond toward the protected edge of the blanket indicated some penetration of energetic atomic oxygen at least five millimeters past the blanket-tray contact interface.

  7. Clinical evaluation of final impressions from three-dimensional printed custom trays.

    PubMed

    Sun, Yuchun; Chen, Hu; Li, Hong; Deng, Kehui; Zhao, Tian; Wang, Yong; Zhou, Yongsheng

    2017-11-02

    This study aimed to evaluate the quality of the final impressions taken by three-dimensional printed custom trays for edentulous patients. Custom trays were designed with or without saddle-shaped tissue stops and fabricated by three-dimensional printing techniques. Manually made trays with photocurable materials were produced as controls. Both 3D printed custom trays and manually made ones were used to take impressions from edentulous patients. After 3D scanning of the final impression, the impression materials were removed, thus the underneath tray surfaces were able to be scanned, allowing the thickness of the impression materials to be measured. Final impressions obtained by pre-border-molded 3D printed trays were scanned as references, to which the flange extension deviations and morphology deviations of the impressions taken by both 3D printed trays and manually made ones were calculated. The results showed that (1) impressions from 3D printed custom trays had better thickness distribution than that of manually made ones; (2) impression morphology deviations in non-marginal area were neither statistic different between 3D printed trays and manually made trays, nor between trays with and without tissue stops; and (3) final impressions taken by custom trays without pre-border-molding were tended to have insufficient flange extensions.

  8. Frequency domain reflectometry NDE for aging cables in nuclear power plants

    NASA Astrophysics Data System (ADS)

    Glass, S. W.; Jones, A. M.; Fifield, L. S.; Hartman, T. S.

    2017-02-01

    Degradation of the cable jacket, electrical insulation, and other cable components of installed cables within nuclear power plants (NPPs) is known to occur as a function of age, temperature, radiation, and other environmental factors. Although system tests verify cable function under normal loads, demonstration of some cable's ability to perform under exceptional loads associated with design-basis events is essential to assuring plant integrity. The cable's ability to perform safely over the initial 40-year planned and licensed life has generally been demonstrated and there have been very few age-related cable failures. With greater than 1000 km of power, control, instrumentation, and other cables typically found in an NPP, replacing all the cables would be a severe cost burden. Justification for life extension to 60 and 80 years requires a cable aging management program that includes condition monitoring to justify cable performance under normal operation as well as accident conditions. A variety of tests are available to assess various aspects of electrical and mechanical cable performance, but none are suitable for all cable configurations nor does any single test confirm all features of interest. One particularly promising test that is beginning to be used more and more by utilities is frequency domain reflectometry (FDR). FDR is a nondestructive electrical inspection technique used to detect and localize faults in power and communication system conductors along the length of a cable from a single connection point. FDR detects discontinuities in the electrical impedance that arise due to cable splices or similar changes along the path of the conductor pair. In addition, FDR has the potential to provide sensitivity to insulation degradation by detecting small changes in impedance between the cable conductors being examined. The technique is also sensitive to cable bends, the particular lay of the cable in tray, proximity to other cable, and other factors that

  9. View of food tray to be used in Skylab program

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A close-up view of a food tray which is scheduled to be used in the Skylab program. Several packages of space food lie beside the tray. The food in the tray is ready to eat. Out of tray, starting from bottom left: grape drink, beef pot roast, chicken and rice, beef sandwiches and sugar cookie cubes, In tray, from back left: orange drink, strawberries, asparagus, prime rib, dinner roll and butterscotch pudding in the center.

  10. 21 CFR 868.6100 - Anesthetic cabinet, table, or tray.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthetic cabinet, table, or tray. 868.6100... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6100 Anesthetic cabinet, table, or tray. (a) Identification. An anesthetic cabinet, table, or tray is a device intended to store...

  11. 21 CFR 868.6100 - Anesthetic cabinet, table, or tray.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Anesthetic cabinet, table, or tray. 868.6100... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6100 Anesthetic cabinet, table, or tray. (a) Identification. An anesthetic cabinet, table, or tray is a device intended to store...

  12. 21 CFR 868.6100 - Anesthetic cabinet, table, or tray.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Anesthetic cabinet, table, or tray. 868.6100... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6100 Anesthetic cabinet, table, or tray. (a) Identification. An anesthetic cabinet, table, or tray is a device intended to store...

  13. 21 CFR 868.6100 - Anesthetic cabinet, table, or tray.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Anesthetic cabinet, table, or tray. 868.6100... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6100 Anesthetic cabinet, table, or tray. (a) Identification. An anesthetic cabinet, table, or tray is a device intended to store...

  14. 21 CFR 868.6100 - Anesthetic cabinet, table, or tray.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Anesthetic cabinet, table, or tray. 868.6100... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6100 Anesthetic cabinet, table, or tray. (a) Identification. An anesthetic cabinet, table, or tray is a device intended to store...

  15. 46 CFR 32.75-15 - Electric bonding and grounding for tanks-TB/ALL.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Hull Requirements for Wood Hull Tank Vessels Constructed Prior... cargo tanks in wood hull tank vessels shall be electrically bonded together with stranded copper cable...

  16. 46 CFR 32.75-15 - Electric bonding and grounding for tanks-TB/ALL.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Hull Requirements for Wood Hull Tank Vessels Constructed Prior... cargo tanks in wood hull tank vessels shall be electrically bonded together with stranded copper cable...

  17. Unilateral neglect: further validation of the baking tray task.

    PubMed

    Appelros, Peter; Karlsson, Gunnel M; Thorwalls, Annika; Tham, Kerstin; Nydevik, Ingegerd

    2004-11-01

    The Baking Tray Task is a comprehensible, simple-to-perform test for use in assessing unilateral neglect. The aim of this study was to validate further its use with stroke patients. The Baking Tray Task was compared with 2 versions of the Behaviour Inattention Test and a test for personal neglect. A total of 270 patients were subjected to a 3-item version of the Behaviour Inattention Test and 40 patients were subjected to an 8-item version of the Behaviour Inattention Test, besides the Baking Tray Task and the personal neglect test. The Baking Tray Task was more sensitive than the 3-item Behaviour Inattention Test, but the 8-item Behaviour Inattention Test was more sensitive than the Baking Tray Task. The best combination of any 3 tests was Baking Tray Task, Reading an article, and Figure copying; the 2 last-mentioned being a part of the 8-item Behaviour Inattention Test. Multi-item tests detect more cases of neglect than do single tests. However, it is tiresome for the patient to undergo a larger test battery than necessary. It is also time-consuming for the staff. Behavioural tests seem more appropriate when assessing neglect. The Baking Tray Task seems to be one of the most sensitive single tests, but its sensitivity can be further enhanced when it is used in combination with other tests.

  18. Surface characterization of selected LDEF tray clamps

    NASA Technical Reports Server (NTRS)

    Cromer, T. F.; Grammer, H. L.; Wightman, J. P.; Young, Philip R.; Slemp, Wayne S.

    1993-01-01

    The surface characterization of chromic acid anodized 6061-T6 aluminum alloy tray clamps has shown differences in surface chemistry depending upon the position on the Long Duration Exposure Facility (LDEF). Water contact angle results showed no changes in wettability of the tray clamps. The overall surface topography of the control, trailing edge(E3) and leading edge(D9) samples was similar. The thickness of the aluminum oxide layer for all samples determined by Auger depth profiling was less than one micron. X-ray photoelectron spectroscopy (XPS) analysis of the tray clamps showed significant differences in the surface composition. Carbon and silicon containing compounds were the primary contaminants detected.

  19. Non Destructive Seal Testing Polymeric Tray

    DTIC Science & Technology

    2006-10-01

    School of Enviromental and Biological Science Rutgers, The State University of New Jersey New Brunswick, New Jersey 08903 Principal Investigator...plate to accept new tray • Insert tray • Push “Continue” button • Lower upper compression plate and hold in position (80 psig) • Raise bottom...John J. Kingman Rd. Fort Belvoir, VA 22060-6221 Contractor: Rutgers, The State University of New Jersey THE CENTER FOR ADVANCED FOOD TECHNOLOGY

  20. A polytetrafluorethylene insulated cable for high temperature oxygen aerospace applications

    NASA Technical Reports Server (NTRS)

    Sheppard, A. T.; Webber, R. G.

    1983-01-01

    For electrical cables to function and survive in the severe high temperature oxygen environment that will be experienced in the external tanks of the space shuttle, extreme cleanliness and material purity is required. A flexible light weight cable has been developed for use in pure oxygen at worst case temperatures of -190 to +260 degrees Centigrade and pressures as high as 44 pounds per square inch absolute. A comprehensive series of tests were performed on cables manufactured to the best commercial practices in order to establish the basic guidelines for control of build configuration as well as each material used in construction of the cable.

  1. A polytetrafluorethylene insulated cable for high temperature oxygen aerospace applications

    NASA Astrophysics Data System (ADS)

    Sheppard, A. T.; Webber, R. G.

    For electrical cables to function and survive in the severe high temperature oxygen environment that will be experienced in the external tanks of the space shuttle, extreme cleanliness and material purity is required. A flexible light weight cable has been developed for use in pure oxygen at worst case temperatures of -190 to +260 degrees Centigrade and pressures as high as 44 pounds per square inch absolute. A comprehensive series of tests were performed on cables manufactured to the best commercial practices in order to establish the basic guidelines for control of build configuration as well as each material used in construction of the cable.

  2. Spectral infrared hemispherical reflectance measurements for LDEF tray clamps

    NASA Technical Reports Server (NTRS)

    Cromwell, B. K.; Shepherd, S. D.; Pender, C. W.; Wood, B. E.

    1993-01-01

    Infrared hemispherical reflectance measurements that were made on 58 chromic acid anodized tray clamps from LDEF are described. The measurements were made using a hemiellipsoidal mirror reflectometer with interferometer for wavelengths between 2-15 microns. The tray clamps investigated were from locations about the entire spacecraft and provided the opportunity for comparing the effects of atomic oxygen at each location. Results indicate there was essentially no dependence on atomic oxygen fluence for the surfaces studied, but there did appear to be a slight dependence on solar radiation exposure. The reflectances of the front sides of the tray clamps consistently were slightly higher than for the protected rear tray clamp surfaces.

  3. In Vitro Comparative Evaluation of Different Types of Impression Trays and Impression Materials on the Accuracy of Open Tray Implant Impressions: A Pilot Study

    PubMed Central

    Gupta, Sonam; Balakrishnan, Dhanasekar

    2017-01-01

    Purpose. For a precise fit of multiple implant framework, having an accurate definitive cast is imperative. The present study evaluated dimensional accuracy of master casts obtained using different impression trays and materials with open tray impression technique. Materials and Methods. A machined aluminum reference model with four parallel implant analogues was fabricated. Forty implant level impressions were made. Eight groups (n = 5) were tested using impression materials (polyether and vinylsiloxanether) and four types of impression trays, two being custom (self-cure acrylic and light cure acrylic) and two being stock (plastic and metal). The interimplant distances were measured on master casts using a coordinate measuring machine. The collected data was compared with a standard reference model and was statistically analyzed using two-way ANOVA. Results. Statistically significant difference (p < 0.05) was found between the two impression materials. However, the difference seen was small (36 μm) irrespective of the tray type used. No significant difference (p > 0.05) was observed between varied stock and custom trays. Conclusions. The polyether impression material proved to be more accurate than vinylsiloxanether impression material. The rigid nonperforated stock trays, both plastic and metal, could be an alternative for custom trays for multi-implant impressions when used with medium viscosity impression materials. PMID:28348595

  4. Cabling design of booster and storage ring construction progress of TPS

    NASA Astrophysics Data System (ADS)

    Wong, Y.-S.; Liu, K.-B.; Liu, C.-Y.; Wang, b.-S.

    2017-06-01

    The 2012 Taiwan Photon Source (TPS) cable construction project started after 10 months to complete the cable laying and installation of power supply. The circumference of the booster ring (BR) is 496.8 m, whereas that of the storage ring (SR) is 518.4 m. Beam current is set to 500 mA at 3.3 GeV. The paper on grounding systems discusses the design of the ground wire (< 0.2 Ω) with low impedance, power supply of the accelerator and cabling tray. The flow and size of the ground current are carefully evaluated to avoid grounded current from flowing everywhere, which causes interference problems. In the design of the TPS, special shielding will be established to isolate the effects of electromagnetic interference on the magnet and ground current. Booster ring dipoles are connected by a series of 54-magnet bending dipole; the cable size of its stranded wire measures 250 mm2, with a total length of 5000 m. Booster ring and storage ring quadrupoles have 150 magnets; the cable size of their stranded wire is 250 mm2, with a total length of 17000 m. Storage ring dipole consists of 48 magnets; the cable size of its stranded wire is 325 mm2, with a total length of 6000 m. This study discusses the power supply cabling design of the storage ring and booster ring construction progress of TPS. The sections of this paper are divided into discussions of the construction of the control and instrument area, cabling layout of booster ring and storage ring, as well as the installation and commission machine. This study also discusses the use of a high-impedance meter to determine the effect of cabling insulation and TPS power supply machine on energy transfer to ensure the use of safe and correct magnet.

  5. Heat and Mass Transfer Measurements for Tray-Fermented Fungal Products

    NASA Astrophysics Data System (ADS)

    Jou, R.-Y.; Lo, C.-T.

    2011-01-01

    In this study, heat and mass transfer in static tray fermentation, which is widely used in solid-state fermentation (SSF) to produce fungal products, such as enzymes or koji, is investigated. Specifically, kinetic models of transport phenomena in the whole-tray chamber are emphasized. The effects of temperature, moisture, and humidity on microbial growth in large-scale static tray fermentation are essential to scale-up SSF and achieve uniform fermentation. In addition, heat and mass transfer of static tray fermentation of Trichoderma fungi with two tray setups—traditional linen coverings and stacks in a temperature-humidity chamber is examined. In both these setups, the following factors of fermentation were measured: air velocity, air temperature, illumination, pH, carbon dioxide (CO2) concentration, and substrate temperature, and the effects of bed height, moisture of substrate, and relative humidity of air are studied. A thin (1 cm) bed at 28 °C and 95 % relative humidity is found to be optimum. Furthermore, mixing was essential for achieving uniform fermentation of Trichoderma fungi. This study has important applications in large-scale static tray fermentation of fungi.

  6. 77 FR 64834 - Exelon Generation Company, LLC; Oyster Creek Nuclear Generating Station; Exemption

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-23

    ... automatic fixed deluge water spray system installed over cable trays and open hatches. The deluge... installed over cable trays and open hatches. The deluge suppression system protecting safety- related cable...

  7. MISSE 1 and 2 Tray Temperature Measurements

    NASA Technical Reports Server (NTRS)

    Harvey, Gale A.; Kinard, William H.

    2006-01-01

    The Materials International Space Station Experiment (MISSE 1 & 2) was deployed August 10,2001 and retrieved July 30,2005. This experiment is a co-operative endeavor by NASA-LaRC. NASA-GRC, NASA-MSFC, NASA-JSC, the Materials Laboratory at the Air Force Research Laboratory, and the Boeing Phantom Works. The objective of the experiment is to evaluate performance, stability, and long term survivability of materials and components planned for use by NASA and DOD on future LEO, synchronous orbit, and interplanetary space missions. Temperature is an important parameter in the evaluation of space environmental effects on materials. The MISSE 1 & 2 had autonomous temperature data loggers to measure the temperature of each of the four experiment trays. The MISSE tray-temperature data loggers have one external thermistor data channel, and a 12 bit digital converter. The MISSE experiment trays were exposed to the ISS space environment for nearly four times the nominal design lifetime for this experiment. Nevertheless, all of the data loggers provided useful temperature measurements of MISSE. The temperature measurement system has been discussed in a previous paper. This paper presents temperature measurements of MISSE payload experiment carriers (PECs) 1 and 2 experiment trays.

  8. 21 CFR 872.3670 - Resin impression tray material.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3670 Resin impression tray material. (a) Identification. Resin impression tray material is a device intended for use in a two-step dental mold fabricating process. The device consists of a resin material, such as methyl methacrylate, and is used to form a...

  9. 21 CFR 872.3670 - Resin impression tray material.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3670 Resin impression tray material. (a) Identification. Resin impression tray material is a device intended for use in a two-step dental mold fabricating process. The device consists of a resin material, such as methyl methacrylate, and is used to form a...

  10. Skylab Food Heating and Serving Tray

    NASA Technical Reports Server (NTRS)

    1970-01-01

    Shown here is the Skylab food heating and serving tray with food, drink, and utensils. The tray contained heating elements for preparing the individual food packets. The food on Skylab was a great improvement over that on earlier spaceflights. It was no longer necessary to squeeze liquified food from plastic tubes. Skylab's kitchen in the Orbital Workshop wardroom was so equipped that each crewman could select his own menu and prepare it to his own taste. The Marshall Space Flight Center had program management responsibility for the development of Skylab hardware and experiments.

  11. T-ray tomography.

    PubMed

    Mittleman, D M; Hunsche, S; Boivin, L; Nuss, M C

    1997-06-15

    We demonstrate tomographic T-ray imaging, using the timing information present in terahertz (THz) pulses in a reflection geometry. THz pulses are reflected from refractive-index discontinuities inside an object, and the time delays of these pulses are used to determine the positions of the discontinuities along the propagation direction. In this fashion a tomographic image can be constructed.

  12. Workers inspect the range safety cable between the ET and SRBs

    NASA Technical Reports Server (NTRS)

    1999-01-01

    Terry Kent (left), United Space Alliance, and James Silviano (right), NASA, inspect the range safety cable between the external tank and solid rocket boosters (SRB) on Space Shuttle Discovery. The cable, which relays a redundant emergency destruction signal between the SRBs in the unlikely event of a contingency, was damaged during close-out operations and is being replaced. Discovery's processing schedule leads to a target launch date of Dec. 6.

  13. Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique

    PubMed Central

    Pastoret, Marie-Hélène; Bühler, Julia; Weiger, Roland

    2017-01-01

    PURPOSE To compare the dimensional accuracy of three impression techniques- a separating foil impression, a custom tray impression, and a stock tray impression. MATERIALS AND METHODS A machined mandibular complete-arch metal model with special modifications served as a master cast. Three different impression techniques (n = 6 in each group) were performed with addition-cured silicon materials: i) putty-wash technique with a prefabricated metal tray (MET) using putty and regular body, ii) single-phase impression with custom tray (CUS) using regular body material, and iii) two-stage technique with stock metal tray (SEP) using putty with a separating foil and regular body material. All impressions were poured with epoxy resin. Six different distances (four intra-abutment and two inter-abutment distances) were gauged on the metal master model and on the casts with a microscope in combination with calibrated measuring software. The differences of the evaluated distances between the reference and the three test groups were calculated and expressed as mean (± SD). Additionally, the 95% confidence intervals were calculated and significant differences between the experimental groups were assumed when confidence intervals did not overlap. RESULTS Dimensional changes compared to reference values varied between -74.01 and 32.57 µm (MET), -78.86 and 30.84 (CUS), and between -92.20 and 30.98 (SEP). For the intra-abutment distances, no significant differences among the experimental groups were detected. CUS showed a significantly higher dimensional accuracy for the inter-abutment distances with -0.02 and -0.08 percentage deviation compared to MET and SEP. CONCLUSION The separation foil technique is a simple alternative to the custom tray technique for single tooth restorations, while limitations may exist for extended restorations with multiple abutment teeth. PMID:28874996

  14. Spectral infrared hemispherical reflectance measurements for LDEF tray clamps

    NASA Technical Reports Server (NTRS)

    Wood, Bobby E.; Cromwell, Brian K.; Pender, Charles W.; Shepherd, Seth D.

    1992-01-01

    This paper describes infrared hemispherical reflectance measurements (2-15 microns) that were made on 58 chromic acid anodized tray clamps retrieved from the LDEF spacecraft. These clamps were used for maintaining the experiments in place and were located at various locations about the spacecraft. Changes in reflectance of the tray clamps at these locations were compared with atomic oxygen fluxes at the same locations. A decrease in absorption band depth was seen for the surfaces exposed to space indicating that there was some surface layer erosion. In all of the surfaces measured, little evidence of contamination was observed and none of the samples showed evidence of the brown nicotine stain that was so prominent in other experiments. Total emissivity values were calculated for both exposed and unexposed tray clamp surfaces. Only small differences, usually less than 1 percent, were observed. The spectral reflectances were measured using a hemi-ellipsoidal mirror reflectometer matched with an interferometer spectrometer. The rapid scanning capability of the interferometer allowed the reflectance measurements to be made in a timely fashion. The ellipsoidal mirror has its two foci separated by 2 inches and located on the major axis. A blackbody source was located at one focus while the tray clamp samples were located at the conjugate focus. The blackbody radiation was modulated and then focused by the ellipsoid onto the tray clamps. Radiation reflected from the tray clamp was sampled by the interferometer by viewing through a hole in the ellipsoid. A gold mirror (reflectance approximately 98 percent) was used as the reference surface.

  15. Tray estimates for low reflux

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barna, B.A.; Ginn, R.F.

    1985-05-01

    In computer programs which perform shortcut calculations for multicomponent distillation, the Gilliland correlation continues to be used even though errors of up to 60% (compared with rigorous plate-to-plate calculations) were shown by Erbar and Maddox. Average absolute differences were approximately 30% for Gilliland's correlation versus 4% for the Erbar-Maddox method. The reason the Gilliland correlation continues to be used appears to be due to the availability of an equation by Eduljee which facilitates the correlation's use in computer program. A new equation is presented in this paper that represents the Erbar-Maddox correlation of trays with reflux for multicomponent distillation. Atmore » low reflux ratios, results show more trays are needed than would be estimated by Gilliland's method.« less

  16. Accuracy of a self-perforating impression tray for dental implants.

    PubMed

    Marotti, Juliana; Tortamano, Pedro; Castilho, Tatiana R R N; Steagall, Washington; Wolfart, Stefan; Haselhuhn, Klaus

    2014-10-01

    Difficulties are involved in impression making with conventional open impression trays. The purpose of this study was to evaluate the accuracy of transferring implant impressions with a self-perforating impression tray. A reference model of a mandible was fabricated, and 4 implants were placed in the regions of the first premolars and lateral incisors (implants 1, 2, 3, 4). Ten impressions of the reference model with polyvinyl siloxane were made for each group; control (conventional open impression tray) and test (self-perforating impression tray; Miratray Implant). A metal bar was screw-retained on implant 1, and the gaps generated at the vestibular face of implants 3 and 4 were measured by optical microcopy. The 2-way ANOVA and least square difference post hoc test were used (α=.05). Higher mean (±SD) values were obtained for the test group than for the control group for both implants: implant 3: 150 ±84 μm for the test group, 73 ±63 μm for the control group (P=.019); implant 4: 129 ±65 μm for the test group, 62 ±61 μm for the control group (P=.04). The self-perforating impression tray provided less accuracy than the conventional open tray. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  17. Applications of T-ray spectroscopy in the petroleum field

    NASA Astrophysics Data System (ADS)

    Al-Douseri, Fatemah M.

    2005-11-01

    Because of heavy usage of petroleum products, which are the main source of energy in daily life and industry, a fast, reliable, and portable analysis system is needed to complement traditional techniques. Terahertz (THz) radiation, or T-rays, is electromagnetic radiation in the 0.1 to 10 THz frequency range. One unique attribute of T-rays is their ability to sensitively measure the induced molecular dipole moments in non-polar liquids such as aromatics, which make up the majority of the contents of many petroleum products. This information can lead to several applications in petroleum analysis. The application of T-rays to petroleum product analysis has the potential to make a significant impact in the petroleum field. In this dissertation, I show the first use of T-ray time-domain spectroscopy and Fourier transform infrared (FTIR) spectroscopy techniques for petroleum product analysis. I report on the feasibility of analyzing selected petroleum products, including gasoline, diesel, lubricating oil, and selected compounds of toluene, ethylbenzene, and xylene (BTEX). With the use of a T-ray time-domain spectrometer. I demonstrate that gasolines with different octane numbers and diesel all show specific absorption coefficients and refractive indexes in the spectral range from 0.5 to 2.0 THz. Furthermore, I report the qualitative and quantitative analysis of selected BTEX components in gasoline and diesel using FTIR spectroscopy in the 50 to 650 cm-1 region. I distinguish gasolines with different octane numbers from diesel and lubricating oil according to their different spectral features. I also determine the concentration of (o, m, p) xylene isomers in gasoline according to their specific absorption bands. The experimental results in this thesis, imply that linking between the knowledge of petroleum products and the development of T-ray spectrometer with the cooperation of industry might translate the T-ray spectroscopic system into a real world application in

  18. Influence of tray rigidity and impression technique on accuracy of polyvinyl siloxane impressions.

    PubMed

    Hoyos, Alex; Soderholm, Karl-Johan

    2011-01-01

    The aim of this study was to determine how tray rigidity and impression technique affect the accuracy of polyvinyl siloxane impressions. Disposable plastic trays and metallic Rim-Lock trays were used in combination with a heavy/light body technique or with two different putty-wash techniques. For each technique-tray combination, 10 impressions were made of a master cast with two steel abutments representing the mandibular right first premolar and second molar, between which a steel rod was placed at the ridge level. Each steel abutment had five marks, while the steel rod in between the two abutments had only one mark, which served as a reference point. With a universal measuring microscope, the x-, y-, and z-coordinates were recorded for each mark on the master cast and impressions. The distances between the different marks and the reference point on the impressions were calculated and compared with those of the master cast. All techniques used with the plastic trays had distances that were significantly different from the master cast (P < .05), while for the metal trays, it was only the heavy/light body technique that resulted in distances that were significantly different from the master cast (P < .05). Plastic trays produced less accurate impressions than metal trays. When metal trays were used, putty-based impressions were dimensionally better than heavy/light body impressions.

  19. TRAY MOUNTAIN ROADLESS AREA, GEORGIA.

    USGS Publications Warehouse

    Nelson, Arthur E.; Chatman, Mark L.

    1984-01-01

    A mineral survey indicates that the Tray Mountain Roadless Area, Georgia has little promise for the occurrence of metallic mineral resources. Rocks underlying the Tray Mountain Roadless Area are suitable for crushed rock or aggregate; however, other sources for these materials are available closer to present markets. There is a possibility for the occurrence of hydrocarbon resources underlying the area at great depth, but no hydrocarbon potential was identified. Detailed studies are needed to establish the presence or absence and mineral-resource potential of olivine, nickel, cobalt, and chrome in the two mafic-ultramafic bodies in the Hayesville thrust sheet. The cause of the lead anomaly in pan concentrate samples taken from the southwest part of the roadless area has not been established; the mineral residence and source of the anomaly remain to be determined.

  20. Modeling and control of a cable-suspended robot for inspection of vertical structures

    NASA Astrophysics Data System (ADS)

    Barry, Nicole; Fisher, Erin; Vaughan, Joshua

    2016-09-01

    In this paper, a cable-driven system is examined for the application of inspection of large, vertical-walled structures such as chemical storage tanks, large ship hulls, and high-rise buildings. Such cable-driven systems are not commonly used for these tasks due to vibration, which decreases inspection accuracy and degrades safety. The flexible nature of the cables make them difficult to control. In this paper, input shaping is implemented on a cable-driven system to reduce vibration. To design the input shapers, a model of the cable-driven system was developed. Analysis of the dominant dynamics and changes in them over the large workspace are also presented. The performance improvements provided by the input shaping controller are quantified through a series of simulations.

  1. Estimation of the Unsteady Aerodynamic Load on Space Shuttle External Tank Protuberances from a Component Wind Tunnel Test

    NASA Technical Reports Server (NTRS)

    Panda, Jayatana; Martin, Fred W.; Sutliff, Daniel L.

    2008-01-01

    At the wake of the Columbia (STS-107) accident it was decided to remove the Protuberance Aerodynamic Load (PAL) Ramp that was originally intended to protect various protuberances outside of the Space Shuttle External Tank from high buffet load induced by cross-flows at transonic speed. In order to establish the buffet load without the PAL ramp, a wind tunnel test was conducted where segments of the protuberances were instrumented with dynamic pressure transducers; and power-spectra of sectional lift and drag forces at various span-wise locations between two adjacent support brackets were measured under different cross flow angles, Mach number and other conditions. Additionally, frequency-dependent spatial correlations between the sectional forces were also established. The sectional forces were then adjusted by the correlation length to establish span-averaged spectra of normal and lateral forces that can be suitably "added" to various other unsteady forces encountered by the protuberance. This paper describes the methodology used for calculating the correlation-adjusted power spectrum of the buffet load. A second part of the paper describes wind-tunnel results on the difference in the buffet load on the protuberances with and without the PAL ramp. In general when the ramp height is the same as that of the protuberance height, such as that found on the liquid Oxygen part of the tank, the ramp is found to cause significant reduction of the unsteady aerodynamic load. However, on the liquid Hydrogen part of the tank, where the Oxygen feed-line is far larger in diameter than the height of the PAL ramp, little protection is found to be available to all but the Cable Tray.

  2. Image Processing Techniques for Assessment of Dental Trays

    DTIC Science & Technology

    2001-10-25

    170 patients having Angle Class I molar relationships with minor malocclusions and teeth including second molars fully erupted without loss of tooth...Abstract-A tray selected for the dental patient must adapt to the curvature of the teeth and allow the impression material to be in appropriate...brands of perforated metal trays with 170 lower arch cast models collected from patients having Angle Class 1 type occlusion with minor malocclusions

  3. SSET Project: Cost-effectiveness Analysis of Surgical Specialty Emergency Trays in the Emergency Department.

    PubMed

    Humphries, Laura S; Shenaq, Deana S; Teven, Chad M; Park, Julie E; Song, David H

    2018-01-01

    We hypothesize that reusable, on-site specialty instrument trays available to plastic surgery residents in the emergency department (ED) for bedside procedures are more cost-effective than disposable on-site and remote re-usable operating room (OR) instruments at our institution. We completed a cost-effectiveness analysis comparing the use of disposable on-site kits and remote OR trays to a hypothetical, custom, reusable tray for ED procedures completed by PRS residents. Material costs of existing OR trays were used to estimate the purchasing and use-cost of a custom on-site tray for the same procedures. Cost of per procedure 'consult time' was estimated using procedure and resident salary. Sixteen bedside procedures were completed over a 4.5 month period. A mean of 2.14 disposable kits were used per-procedure. Mean consultation time was 1.66 hours. Procedures that used OR trays took 3 times as long as procedures that used on-site kits (4 vs. 1.1 hours). Necessary, additional instruments were unavailable for 75% of procedures. Mean cost of using disposable kits and OR trays was $115.03/procedure versus an estimated $26.67/procedure cost of using a custom tray, yielding $88.36/procedure cost-savings. Purchase of a single custom tray ($1,421.55) would be redeemed after 2.3 weeks at 1 procedure/day. Purchasing 4 trays has projected annual cost-savings of $26,565.20. The purchase of specialized procedure trays will yield valuable time and cost-savings while providing quality patient care. Improving time efficiency will help achieve the Accreditation Council of Graduate Medical Education (ACGME) goals of maintaining resident well-being and developing quality improvement competency.

  4. Application of FDM three-dimensional printing technology in the digital manufacture of custom edentulous mandible trays

    PubMed Central

    Chen, Hu; Yang, Xu; Chen, Litong; Wang, Yong; Sun, Yuchun

    2016-01-01

    The objective was to establish and evaluate a method for manufacture of custom trays for edentulous jaws using computer aided design and fused deposition modeling (FDM) technologies. A digital method for design the custom trays for edentulous jaws was established. The tissue surface data of ten standard mandibular edentulous plaster models, which was used to design the digital custom tray in a reverse engineering software, were obtained using a 3D scanner. The designed tray was printed by a 3D FDM printing device. Another ten hand-made custom trays were produced as control. The 3-dimentional surface data of models and custom trays was scanned to evaluate the accuracy of reserved impression space, while the difference between digitally made trays and hand-made trays were analyzed. The digitally made custom trays achieved a good matching with the mandibular model, showing higher accuracy than the hand-made ones. There was no significant difference of the reserved space between different models and its matched digitally made trays. With 3D scanning, CAD and FDM technology, an efficient method of custom tray production was established, which achieved a high reproducibility and accuracy. PMID:26763620

  5. Skylab Food Heating and Serving Tray

    NASA Technical Reports Server (NTRS)

    1970-01-01

    Shown here is the Skylab food heating and serving tray in its stowed position. The Marshall Space Flight Center had program management responsibility for the development of Skylab hardware and experiments.

  6. STS-5 crewmembers with meal tray assembly on middeck

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Commander Brand (in dark blue shirt), Pilot Overmyer (left), and Mission Specialist (MS) Lenoir (right) conduct microgravity experiments with food containers and meal tray assemblies in front of middeck port side wall and side hatch. Brand prepares to eat as meal tray assembly floats above his chest and Overmeyer and Lenoir look on. Sign on port side wall is labeled STS-5 Message Board.

  7. Bleaching and temporomandibular disorder using a half tray design: a clinical report.

    PubMed

    Robinson, F G; Haywood, V B

    2000-05-01

    A maxillary soft, custom-fitted tray was fabricated for a patient to perform nightguard vital bleaching. Treatment was interrupted after the patient experienced pain in the temporomandibular joint area shortly after wearing the bleaching prosthesis. The tray was trimmed so the labial, incisal and buccal cusps were covered and Sc) the patient had complete tooth-to-tooth contact in the maximum intercuspal position. The prosthesis proved to be retentive even without the presence of the bleaching material. The thick, sticky bleaching material was contained in the half tray design and the tray was held in place. The patient was able to continue the bleaching process for the 2-week duration necessary to achieve successful lightening of the teeth without further TMD symptoms.

  8. Will Tray Rations be Available for the Next War?

    DTIC Science & Technology

    1990-03-18

    industry giants into the competition. Companies like Pillsbury and Green Giant competed for the opportunity to enter the T- Ration market.5 However...document may not be released for open pubicatio and it hu been cleaed by dw appmpriat militay ase or Ipoemment alency. WILL TRAY RATIONS BE AVAILABLE...TITLE (and Subtitle) -- T yPE OF REPORT & PERIOD COVERED Will Tray Rations Be Available For the Next War? Study Project 6. PERFORMING ORG. REPORT

  9. A New Idea for Dissecting Tray

    ERIC Educational Resources Information Center

    Branham, Arthur

    1976-01-01

    A method of preparing a special dissecting tray to be used with transmitted light as well as reflected light is presented. It may also be used with an overhead projector to illustrate some skeletal structures in vertebrates. (Author/EB)

  10. A comparative study of inter-abutment distance of dies made from full arch dual-arch impression trays with those made from full arch stock trays: an in vitro study.

    PubMed

    Reddy, Jagan Mohan; Prashanti, E; Kumar, G Vinay; Suresh Sajjan, M C; Mathew, Xavier

    2009-01-01

    The dual-arch impression technique is convenient in that it makes the required maxillary and mandibular impressions, as well as the inter-occlusal record in one procedure. The accuracy of inter-abutment distance in dies fabricated from dual-arch impression technique remains in question because there is little information available in the literature. This study was conducted to evaluate the accuracy of inter-abutment distance in dies obtained from full arch dual-arch trays with those obtained from full arch stock metal trays. The metal dual-arch trays showed better accuracy followed by the plastic dual-arch and stock dentulous trays, respectively, though statistically insignificant. The pouring sequence did not have any effect on the inter-abutment distance statistically, though pouring the non-working side of the dual-arch impression first showed better accuracy.

  11. Polylactic acid trays for fresh-food packaging: A Carbon Footprint assessment.

    PubMed

    Ingrao, Carlo; Tricase, Caterina; Cholewa-Wójcik, Agnieszka; Kawecka, Agnieszka; Rana, Roberto; Siracusa, Valentina

    2015-12-15

    This paper discusses application of Carbon Footprint (CF) for quantification of the 100-year Global Warming Potential (GWP100) associated with the life cycle of polylactic acid (PLA) trays for packaging of fresh foods. A comparison with polystyrene (PS)-based trays was done considering two different transport system scenarios for PLA-granule supply to the tray production firm: a transoceanic freight vessel and an intercontinental freight aircraft. Doing so enabled estimation of the influence of the transportation phase on the GHG-emission rate associated with the PLA-trays' life cycle. From the assessment, the GWP100 resulted to be mainly due to PLA-granulate production and to its transportation to the tray manufacturing facility. Also, the study documented that, depending upon the transport system considered, the CF associated with the life cycle of the PLA trays can worsen so much that the latter are no longer GHG-emission saving as they are expected to be compared to the PS ones. Therefore, based upon the findings of the study, it was possible for the authors to understand the importance and the need of accounting for the transport-related issues in the design of PLA-based products, thus preserving their environmental soundness compared to traditional petroleum-based products. In this context, the study could be used as the base to reconsider the merits of PLA usage for product manufacturing, especially when high distances are implied, as in this analysed case. So, the authors believe that new research and policy frameworks should be designed and implemented for both development and promotion of more globally sustainable options. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Scooped Material on Rover Observation Tray

    NASA Image and Video Library

    2012-10-25

    Sample material from the fourth scoop of Martian soil collected by NASA Mars rover Curiosity is on the rover observation tray in this image taken during the mission 78th Martian sol, Oct. 24, 2012 by Curiosity left Navigation Camera.

  13. The effect of impression volume and double-arch trays on the registration of maximum intercuspation.

    PubMed

    Hahn, Sara M; Millstein, Philip L; Kinnunen, Taru H; Wright, Robert F

    2009-12-01

    The type of double-arch trays used may affect occlusion. The purpose of this study was to determine what effect, if any, double-arch tray design and impression material volume had on the registration of maximum intercuspation (MI). Quadrant impressions were made on articulated fracture-resistant dental casts mounted in maximum intercuspation occlusion. Three types of sideless double-arch impression trays were used: First Bite with nylon webbing, Sultan's 3-Way with double crosshatch webbing, and Premium's 3-in-1 Tray with single crosshatch webbing. Vinyl polysiloxane impression material (Aquasil Ultra Rigid Fast Set) was distributed at 2 different volumes (5.4 ml and 8.3 ml), and 60 impressions were made (n=10). A weight of 1.2 kg was placed on the upper arm of an Artex articulator, ensuring complete closure. The impressions were allowed to polymerize for 5 minutes. After polymerization, specimens were placed on a light box, and a camera set at a fixed distance was used to capture the light transmission that was projected through the impression material. The camera transferred the information to an image analysis program (ImageJ). This system allowed the different amounts of light projected through the impression to be translated into a gray scale value (GSV), which was assigned a thickness value, in millimeters, of a specified occlusal contact area. To assess reliability of the experimental design, 10 control impressions were made by directly applying impression material onto the typodont. These were analyzed in the same manner as the impressions made with trays. A 2-way ANOVA comparing volume by tray type was used (alpha=.05). This was followed by a Tukey HSD test. There was no main effect for volume of impression material (P=.71). Tray type was significantly different (P<.001). Impressions made with Sultan trays were significantly less accurate than impressions made with First Bite or Premium impression trays. The Premium tray type had the highest mean (SD) GSV

  14. Modeling of Electrical Cable Failure in a Dynamic Assessment of Fire Risk

    NASA Astrophysics Data System (ADS)

    Bucknor, Matthew D.

    Fires at a nuclear power plant are a safety concern because of their potential to defeat the redundant safety features that provide a high level of assurance of the ability to safely shutdown the plant. One of the added complexities of providing protection against fires is the need to determine the likelihood of electrical cable failure which can lead to the loss of the ability to control or spurious actuation of equipment that is required for safe shutdown. A number of plants are now transitioning from their deterministic fire protection programs to a risk-informed, performance based fire protection program according to the requirements of National Fire Protection Association (NFPA) 805. Within a risk-informed framework, credit can be taken for the analysis of fire progression within a fire zone that was not permissible within the deterministic framework of a 10 CFR 50.48 Appendix R safe shutdown analysis. To perform the analyses required for the transition, plants need to be able to demonstrate with some level of assurance that cables related to safe shutdown equipment will not be compromised during postulated fire scenarios. This research contains the development of new cable failure models that have the potential to more accurately predict electrical cable failure in common cable bundle configurations. Methods to determine the thermal properties of the new models from empirical data are presented along with comparisons between the new models and existing techniques used in the nuclear industry today. A Dynamic Event Tree (DET) methodology is also presented which allows for the proper treatment of uncertainties associated with fire brigade intervention and its effects on cable failure analysis. Finally a shielding analysis is performed to determine the effects on the temperature response of a cable bundle that is shielded from a fire source by an intervening object such as another cable tray. The results from the analyses demonstrate that models of similar

  15. Tibial Tray Thickness Significantly Increases Medial Tibial Bone Resorption in Cobalt-Chromium Total Knee Arthroplasty Implants.

    PubMed

    Martin, J Ryan; Watts, Chad D; Levy, Daniel L; Miner, Todd M; Springer, Bryan D; Kim, Raymond H

    2017-01-01

    Stress shielding is an uncommon complication associated with primary total knee arthroplasty. Patients are frequently identified radiographically with minimal clinical symptoms. Very few studies have evaluated risk factors for postoperative medial tibial bone loss. We hypothesized that thicker cobalt-chromium tibial trays are associated with increased bone loss. We performed a retrospective review of 100 posterior stabilized, fixed-bearing total knee arthroplasty where 50 patients had a 4-mm-thick tibial tray (thick tray cohort) and 50 patients had a 2.7-mm-thick tibial tray (thin tray cohort). A clinical evaluation and a radiographic assessment of medial tibial bone loss were performed on both cohorts at a minimum of 2 years postoperatively. Mean medial tibial bone loss was significantly higher in the thick tray cohort (1.07 vs 0.16 mm; P = .0001). In addition, there were significantly more patients with medial tibial bone loss in the thick tray group compared with the thin tray group (44% vs 10%, P = .0002). Despite these differences, there were no statistically significant differences in range of motion, knee society score, complications, or revision surgeries performed. A thicker cobalt-chromium tray was associated with significantly more medial tibial bone loss. Despite these radiographic findings, we found no discernable differences in clinical outcomes in our patient cohort. Further study and longer follow-up are needed to understand the effects and clinical significance of medial tibial bone loss. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Assessing the magnitude and costs of intraoperative inefficiencies attributable to surgical instrument trays.

    PubMed

    Stockert, Emily Walker; Langerman, Alexander

    2014-10-01

    Efficiency in the operating room has become a topic of great interest. This study aimed to quantify the percent use of instruments among common instrument trays across 4 busy surgical services: Otolaryngology, Plastic Surgery, Bariatric Surgery, and Neurosurgery. We further aimed to calculate the costs associated with tray and instrument sterilization, as well as the implications of missing or damaged instruments. This was a single-site, observational study conducted on the surgical instrumentation at a large academic medical center in Chicago. Data were collected through direct observation by a trained investigator. Operating room instrument use and labor time required for cleaning and repacking instrument trays in central sterile processing (CSP) were analyzed using descriptive statistics and linear regression. Institutional data on volume and expenses were gathered from hospital leadership. Forty-nine procedures and 237 individual trays were observed. Average instrument (±SD)use rates were 13.0% for Otolaryngology (±4.2%), 15.5% for Plastic Surgery (±2.9%), 18.2% for Bariatric Surgery (±5.0%), and 21.9% for Neurosurgery (±1.7%). An increasing number of instruments per tray was associated with decreased use and increased instrument error rate. Using recorded labor time, the cost of cleaning and repackaging an individual instrument was calculated to be $0.10. Adding in CSP operating expenses and instrument depreciation per use, total processing cost per instrument increases to $0.51 or more. Our study demonstrates that the percent use of instruments across surgical specialties and multiple tray types is low. Attention to tray composition may result in immediate and significant cost savings. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  17. The Skills Minister's In-Tray

    ERIC Educational Resources Information Center

    Hancock's, Matthew

    2012-01-01

    In the "Adults Learning" autumn issue, the journal staff asked key players in the learning and skills sector what they thought should be at the top of new skills minister Matthew Hancock's in-tray. The new minister shares that his job in the further education and skills sector is to rise to the challenge and play his full part in giving…

  18. Compact sieve-tray distillation column for ammonia-water absorption heat pump: Part 1 -- Design methodology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anand, G.; Erickson, D.C.

    1999-07-01

    The distillation column is a key component of ammonia-water absorption units including advanced generator-absorber heat exchange (GAX) cycle heat pumps. The design of the distillation column is critical to unit performance, size, and cost. The distillation column can be designed with random packing, structured packing, or various tray configurations. A sieve-tray distillation column is the least complicated tray design and is less costly than high-efficiency packing. Substantial literature is available on sieve tray design and performance. However, most of the correlations and design recommendations were developed for large industrial hydrocarbon systems and are generally not directly applicable to the compactmore » ammonia-water column discussed here. The correlations were reviewed and modified as appropriate for this application, and a sieve-tray design model was developed. This paper presents the sieve-tray design methodology for highly compact ammonia-water columns. A conceptual design of the distillation column for an 8 ton vapor exchange (VX) GAX heat pump is presented, illustrating relevant design parameters and trends. The design process revealed several issues that have to be investigated experimentally to design the final optimized rectifier. Validation of flooding and weeping limits and tray/point efficiencies are of primary importance.« less

  19. [Application of individual light-curing resin tray as edge plastic material in complete denture modulo].

    PubMed

    Chai, Mei; Tang, Xuyan; Liang, Guangku

    2015-12-01

    To investigate clinical effect of individual light-curing resin tray as edge plastic material in complete denture modulo.
 A total of 30 patients with poor condition for alveolar ridge of mandible were chosen individual tray with individual light-curing resin tray for material edge shaping or traditional individual impression tray for edge shaping cream to produce complete denture. The operability, questionnaire about denture retention, comfort, mucosal cases and chewing function in the process of shaping the edge were investigated three months later after wearing dentures.
 There was no significant difference in retention, comfort, mucosa and the chewing function between the two mandibular denture impression methods. However, the patients with individual light-curing resin tray as edge shaping material felt better in the process than that in the patients with die-cream as the edge shaping material (P<0.05). Furthermore, the manipulation with individual light-curing resin tray as edge shaping material is easy for doctor.
 Although the clinical effect of Individual light-curing resin tray material as the edge shaping material is equal to that of impression cream, it saves time and human resource. Moreover, it is more acceptable for the patients and thus it can be spread in clinics.

  20. Numerical modeling of a spherical buoy moored by a cable in three dimensions

    NASA Astrophysics Data System (ADS)

    Zhu, Xiangqian; Yoo, Wan-Suk

    2016-05-01

    Floating facilities have been studied based on the static analysis of mooring cables over the past decades. To analyze the floating system of a spherical buoy moored by a cable with a higher accuracy than before, the dynamics of the cables are considered in the construction of the numerical modeling. The cable modeling is established based on a new element frame through which the hydrodynamic loads are expressed efficiently. The accuracy of the cable modeling is verified with an experiment that is conducted by a catenary chain moving in a water tank. In addition, the modeling of a spherical buoy is established with respect to a spherical coordinate in three dimensions, which can suffers the gravity, the variable buoyancy and Froude-Krylov loads. Finally, the numerical modeling for the system of a spherical buoy moored by a cable is established, and a virtual simulation is proceeded with the X- and Y-directional linear waves and the X-directional current. The comparison with the commercial simulation code ProteusDS indicates that the system is accurately analyzed by the numerical modeling. The tensions within the cable, the motions of the system, and the relationship between the motions and waves are illustrated according to the defined sea state. The dynamics of the cables should be considered in analyzing the floating system of a spherical buoy moored by a cable.

  1. Novel method of fabricating individual trays for maxillectomy patients by computer-aided design and rapid prototyping.

    PubMed

    Huang, Zhi; Wang, Xin-zhi; Hou, Yue-Zhong

    2015-02-01

    Making impressions for maxillectomy patients is an essential but difficult task. This study developed a novel method to fabricate individual trays by computer-aided design (CAD) and rapid prototyping (RP) to simplify the process and enhance patient safety. Five unilateral maxillectomy patients were recruited for this study. For each patient, a computed tomography (CT) scan was taken. Based on the 3D surface reconstruction of the target area, an individual tray was manufactured by CAD/RP. With a conventional custom tray as control, two final impressions were made using the different types of tray for each patient. The trays were sectioned, and in each section the thickness of the material was measured at six evenly distributed points. Descriptive statistics and paired t-test were used to examine the difference of the impression thickness. SAS 9.3 was applied in the statistical analysis. Afterwards, all casts were then optically 3D scanned and compared digitally to evaluate the feasibility of this method. Impressions of all five maxillectomy patients were successfully made with individual trays fabricated by CAD/RP and traditional trays. The descriptive statistics of impression thickness measurement showed slightly more uneven results in the traditional trays, but no statistical significance was shown. A 3D digital comparison showed acceptable discrepancies within 1 mm in the majority of cast areas. The largest difference of 3 mm was observed in the buccal wall of the defective areas. Moderate deviations of 1 to 2 mm were detected in the buccal and labial vestibular groove areas. This study confirmed the feasibility of a novel method of fabricating individual trays by CAD/RP. Impressions made by individual trays manufactured using CAD/RP had a uniform thickness, with an acceptable level of accuracy compared to those made through conventional processes. © 2014 by the American College of Prosthodontists.

  2. [Evaluation of production and clinical working time of computer-aided design/computer-aided manufacturing (CAD/CAM) custom trays for complete denture].

    PubMed

    Wei, L; Chen, H; Zhou, Y S; Sun, Y C; Pan, S X

    2017-02-18

    To compare the technician fabrication time and clinical working time of custom trays fabricated using two different methods, the three-dimensional printing custom trays and the conventional custom trays, and to prove the feasibility of the computer-aided design/computer-aided manufacturing (CAD/CAM) custom trays in clinical use from the perspective of clinical time cost. Twenty edentulous patients were recruited into this study, which was prospective, single blind, randomized self-control clinical trials. Two custom trays were fabricated for each participant. One of the custom trays was fabricated using functional suitable denture (FSD) system through CAD/CAM process, and the other was manually fabricated using conventional methods. Then the final impressions were taken using both the custom trays, followed by utilizing the final impression to fabricate complete dentures respectively. The technician production time of the custom trays and the clinical working time of taking the final impression was recorded. The average time spent on fabricating the three-dimensional printing custom trays using FSD system and fabricating the conventional custom trays manually were (28.6±2.9) min and (31.1±5.7) min, respectively. The average time spent on making the final impression with the three-dimensional printing custom trays using FSD system and the conventional custom trays fabricated manually were (23.4±11.5) min and (25.4±13.0) min, respectively. There was significant difference in the technician fabrication time and the clinical working time between the three-dimensional printing custom trays using FSD system and the conventional custom trays fabricated manually (P<0.05). The average time spent on fabricating three-dimensional printing custom trays using FSD system and making the final impression with the trays are less than those of the conventional custom trays fabricated manually, which reveals that the FSD three-dimensional printing custom trays is less time

  3. Space Shuttle food tray

    NASA Image and Video Library

    1983-11-28

    STS009-05-0153 (28 Nov. - 8 Dec. 1983) --- Though STS-9 was the space shuttle Columbia's sixth spaceflight, it was the first opportunity for an onboard galley, some of the results of which are shown in this 35mm scene on the flight deck. The metal tray makes for easy preparation and serving of in-space meals for crew members. This crewman is seated at the pilot's station on the flight deck. The actual galley is located in the middeck. Photo credit: NASA

  4. Surgical instrument similarity metrics and tray analysis for multi-sensor instrument identification

    NASA Astrophysics Data System (ADS)

    Glaser, Bernhard; Schellenberg, Tobias; Franke, Stefan; Dänzer, Stefan; Neumuth, Thomas

    2015-03-01

    A robust identification of the instrument currently used by the surgeon is crucial for the automatic modeling and analysis of surgical procedures. Various approaches for intra-operative surgical instrument identification have been presented, mostly based on radio-frequency identification (RFID) or endoscopic video analysis. A novel approach is to identify the instruments on the instrument table of the scrub nurse with a combination of video and weight information. In a previous article, we successfully followed this approach and applied it to multiple instances of an ear, nose and throat (ENT) procedure and the surgical tray used therein. In this article, we present a metric for the suitability of the instruments of a surgical tray for identification by video and weight analysis and apply it to twelve trays of four different surgical domains (abdominal surgery, neurosurgery, orthopedics and urology). The used trays were digitized at the central sterile services department of the hospital. The results illustrate that surgical trays differ in their suitability for the approach. In general, additional weight information can significantly contribute to the successful identification of surgical instruments. Additionally, for ten different surgical instruments, ten exemplars of each instrument were tested for their weight differences. The samples indicate high weight variability in instruments with identical brand and model number. The results present a new metric for approaches aiming towards intra-operative surgical instrument detection and imply consequences for algorithms exploiting video and weight information for identification purposes.

  5. Efficacy of tray adhesives for the adhesion of elastomer rubber impression materials to impression modeling plastics for border molding.

    PubMed

    Nishigawa, G; Sato, T; Suenaga, K; Minagi, S

    1998-02-01

    Tray adhesive, which is used for the adhesion of elastomer rubber impression materials to a custom resin tray, lowers the retention of the impression materials to the impression modeling plastics, as some ingredients of tray adhesive make the impression modeling plastic soft and tacky. The efficacy of tray adhesive, which is used for the adhesion of elastomer rubber impression materials to a custom resin tray, on the adhesion between elastomer rubber impression material and impression modeling plastic was investigated. Four silicone rubber impression materials (two addition reaction types and two condensation reaction types), two polysulfide rubber impression materials, and one impression modeling plastic were used in this study. Tensile strength between elastomer rubber impression material and impression modeling plastic with or without the application of tray adhesive was evaluated. Although tray adhesives for both addition reaction type and both condensation reaction type of silicone impression materials and one tray adhesive for polysulfide rubber impression material increased the tensile strength between the impression material and impression modeling plastic, one tray adhesive for polysulfide rubber impression material decreased the tensile strength when sufficient drying time was not applied.

  6. T-ray relevant frequencies for osteosarcoma classification

    NASA Astrophysics Data System (ADS)

    Withayachumnankul, W.; Ferguson, B.; Rainsford, T.; Findlay, D.; Mickan, S. P.; Abbott, D.

    2006-01-01

    We investigate the classification of the T-ray response of normal human bone cells and human osteosarcoma cells, grown in culture. Given the magnitude and phase responses within a reliable spectral range as features for input vectors, a trained support vector machine can correctly classify the two cell types to some extent. Performance of the support vector machine is deteriorated by the curse of dimensionality, resulting from the comparatively large number of features in the input vectors. Feature subset selection methods are used to select only an optimal number of relevant features for inputs. As a result, an improvement in generalization performance is attainable, and the selected frequencies can be used for further describing different mechanisms of the cells, responding to T-rays. We demonstrate a consistent classification accuracy of 89.6%, while the only one fifth of the original features are retained in the data set.

  7. Tropical field performance of dual-pass PV tray dryer

    NASA Astrophysics Data System (ADS)

    Iskandar, A. Noor; Ya'acob, M. E.; Anuar, M. S.

    2017-09-01

    Solar Photovoltaic technology has become the preferable solution in many countries around the globe to solve the ever increasing energy demand of the consumers. In line with the consumer need, food processing technology has huge potentials of integration with the renewable energy resources especially in drying process which consumes the highest electricity loads. Traditionally, the solar dryer technology was applied in agriculture and food industries utilizing the sun's energy for drying process, but this is highly dependable on the weather condition and surrounding factors. This work shares some field performance of the new design of portable dual-pass PV tray dryer for drying crops in an enclosed system. The dual-pass PV tray dryer encompass a lightweight aluminium box structure with dimensions of 1.1m (L) x 0.6m (W) x 0.2m (H) and can hold a load capacity of 300g - 3kg of crop depending on the types of the crops. Experiments of field performance monitoring were conducted in October -November 2016 which justifies a considerable reduction in time and crops quality improvement when using the dual-pass PV tray dryer as compared to direct-sun drying.

  8. Accuracy of Different Implant Impression Techniques: Evaluation of New Tray Design Concept.

    PubMed

    Liu, David Yu; Cader, Fathima Nashmie; Abduo, Jaafar; Palamara, Joseph

    2017-12-29

    To evaluate implant impression accuracy with a new tray design concept in comparison to nonsplinted and splinted impression techniques for a 2-implant situation. A reference bar titanium framework was fabricated to fit on 2 parallel implants. The framework was used to generate a resin master model with 2 implants that fit precisely against the framework. Three impression techniques were evaluated: (1) nonsplinted, (2) splinted, and (3) nonsplinted with modified tray impressions. All the trays were fabricated from light-cured acrylic resin material with openings that corresponded to the implant impression copings. Ten impressions were taken for each technique using poly(vinyl siloxane) impression material. The impressions were poured with type IV dental stone to generate the test casts. A rosette strain gauge was bonded to the middle of the framework. As the framework retaining screws were tightened on each test cast, the developed strains were recorded until the completion of the tightening to 35 Ncm. The generated strains of the rosette strain gauge were used to calculate the maximum principal strain. A statistically significant difference was observed among the different impression techniques. The modified tray design impression technique was associated with the least framework strains, which indicates greater accuracy compared with the other techniques. There was no significant difference between the splinted and the nonsplinted impression techniques. The new tray design concept appeared to produce more accurate implant impressions than the other techniques. Despite the statistical difference among the impression techniques, the clinical significance of this difference is yet to be determined. © 2017 by the American College of Prosthodontists.

  9. The Thermal Regime Around Buried Submarine High-Voltage Cables

    NASA Astrophysics Data System (ADS)

    Emeana, C. J.; Dix, J.; Henstock, T.; Gernon, T.; Thompson, C.; Pilgrim, J.

    2015-12-01

    The expansion of offshore renewable energy infrastructure and the desire for "trans-continental shelf" power transmission, all require the use of submarine High Voltage (HV) cables. These cables have maximum operating surface temperatures of up to 70oC and are typically buried at depths of 1-2 m beneath the seabed, within the wide range of substrates found on the continental shelf. However, the thermal properties of near surface shelf sediments are poorly understood and this increases the uncertainty in determining the required cable current ratings, cable reliability and the potential effects on the sedimentary environments. We present temperature measurements from a 2D laboratory experiment, designed to represent a buried, submarine HV cable. We used a large (2.5 m-high) tank, filled with water-saturated ballotini and instrumented with 120 thermocouples, which measured the time-dependent 2D temperature distributions around the heat source. The experiments use a buried heat source to represent a series of realistic cable surface temperatures with the aim for identifying the thermal regimes generated within typical non-cohesive shelf sediments: coarse silt, fine sand and very coarse sand. The steady state heat flow regimes, and normalised and radial temperature distributions were assessed. Our results show that at temperatures up to 60°C above ambient, the thermal regimes are conductive for the coarse silt sediments and convective for the very coarse sand sediments even at 7°C above ambient. However, the heat flow pattern through the fine sand sediment shows a transition from conductive to convective heat flow at a temperature of approximately 20°C above ambient. These findings offer an important new understanding of the thermal regimes associated with submarine HV cables buried in different substrates and has huge impacts on cable ratings as the IEC 60287 standard only considers conductive heat flow as well as other potential near surface impacts.

  10. Digital impression and jaw relation record for the fabrication of CAD/CAM custom tray.

    PubMed

    Kanazawa, Manabu; Iwaki, Maiko; Arakida, Toshio; Minakuchi, Shunsuke

    2018-03-16

    This article describes the protocol of a digital impression technique to make an impression and recording of the jaw relationship of edentulous patients for the fabrication of CAD/CAM custom tray using computer-aided design and manufacturing (CAD/CAM) technology. Scan the maxillary and mandibular edentulous jaws using an intraoral scanner. Scan the silicone jig with the maxillary and mandibular jaws while keeping the jig between the jaws. Import the standard tessellation language data of the maxillary and mandibular jaws and jig to make a jaw relation record and fabricate custom trays (CAD/CAM trays) using a rapid prototyping system. Make a definitive impression of the maxillary and mandibular jaws using the CAD/CAM trays. Digitalization of the complete denture fabrication process can simplify the complicated treatment and laboratory process of conventional methods In addition, the proposed method enables quality control regardless of the operator's experience and technique. Copyright © 2018. Published by Elsevier Ltd.

  11. Modeling vibration response and damping of cables and cabled structures

    NASA Astrophysics Data System (ADS)

    Spak, Kaitlin S.; Agnes, Gregory S.; Inman, Daniel J.

    2015-02-01

    In an effort to model the vibration response of cabled structures, the distributed transfer function method is developed to model cables and a simple cabled structure. The model includes shear effects, tension, and hysteretic damping for modeling of helical stranded cables, and includes a method for modeling cable attachment points using both linear and rotational damping and stiffness. The damped cable model shows agreement with experimental data for four types of stranded cables, and the damped cabled beam model shows agreement with experimental data for the cables attached to a beam structure, as well as improvement over the distributed mass method for cabled structure modeling.

  12. 30 CFR 77.605 - Breaking trailing cable and power cable connections.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Breaking trailing cable and power cable... OF UNDERGROUND COAL MINES Trailing Cables § 77.605 Breaking trailing cable and power cable connections. Trailing cable and power cable connections between cables and to power sources shall not be made...

  13. 30 CFR 77.605 - Breaking trailing cable and power cable connections.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Breaking trailing cable and power cable... OF UNDERGROUND COAL MINES Trailing Cables § 77.605 Breaking trailing cable and power cable connections. Trailing cable and power cable connections between cables and to power sources shall not be made...

  14. 30 CFR 77.605 - Breaking trailing cable and power cable connections.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Breaking trailing cable and power cable... OF UNDERGROUND COAL MINES Trailing Cables § 77.605 Breaking trailing cable and power cable connections. Trailing cable and power cable connections between cables and to power sources shall not be made...

  15. 30 CFR 77.605 - Breaking trailing cable and power cable connections.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Breaking trailing cable and power cable... OF UNDERGROUND COAL MINES Trailing Cables § 77.605 Breaking trailing cable and power cable connections. Trailing cable and power cable connections between cables and to power sources shall not be made...

  16. 30 CFR 77.605 - Breaking trailing cable and power cable connections.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Breaking trailing cable and power cable... OF UNDERGROUND COAL MINES Trailing Cables § 77.605 Breaking trailing cable and power cable connections. Trailing cable and power cable connections between cables and to power sources shall not be made...

  17. Challenges to validation of a complex nonsterile medical device tray.

    PubMed

    Prince, Daniel; Mastej, Jozef; Hoverman, Isabel; Chatterjee, Raja; Easton, Diana; Behzad, Daniela

    2014-01-01

    Validation by steam sterilization of reusable medical devices requires careful attention to many parameters that directly influence whether or not complete sterilization occurs. Complex implant/instrument tray systems have a variety of configurations and components. Geobacillus stearothermophilus biological indicators (BIs) are used in overkill cycles to to simulate worst case conditions and are intended to provide substantial sterilization assurance. Survival of G. stearothermophilus spores was linked to steam access and size of load in the chamber. By a small and reproducible margin, it was determined that placement of the trays in a rigid container into minimally loaded chambers were more difficult to completely sterilize than maximally loaded chambers.

  18. Herbal dryer: drying of ginger (zingiber officinale) using tray dryer

    NASA Astrophysics Data System (ADS)

    Haryanto, B.; Hasibuan, R.; Alexander; Ashari, M.; Ridha, M.

    2018-02-01

    Drying is widely used as a method to preserve food because of its convenience and affordability. Drying of ginger using tray dryer were carried out at various drying conditions, such as air-drying flow, air-drying temperature, and sample dimensions, to achieve the highest drying rate. Samples with various dimensions were placed in the tray dryer and dried using various air-drying flow and temperatures. The weights of samples were observed every 3 minutes interval. Drying was stopped after three times of constant weighing. Data of drying was collected to make the drying curves. Drying curves show that the highest drying rate is achieved using highest air flow and temperature.

  19. Recolonization of macrofauna in unpolluted sands placed in a polluted yachting harbour: A field approach using experimental trays

    NASA Astrophysics Data System (ADS)

    Guerra-García, J. M.; García-Gómez, J. C.

    2009-01-01

    A field experiment using trays was conducted at Ceuta's yachting harbour, North Africa, to study the effect in recolonization of placing trays with unpolluted defaunate sediments (fine and gross sands with low contents of organic matter) inside an enclosed yachting harbour characterized by high percentages of silt and clay and high concentrations of organic matter. Sediment recolonization in the trays was mainly undertaken by the species living naturally at the yachting harbour, which recolonized both uncontaminated gross and fine sand trays (such as the crustaceans Corophium runcicorne, Corophium sextonae and Nebalia bipes, the mollusc Parvicardium exiguum and the polychaete Pseudomalacoceros tridentata). However, other species like the polychaetes Cirriformia tentaculata and Platynereis dumerilii, although also abundant in the yachting harbour, were unable to colonize the trays through transport of larvae and/or adults in the water column. The recolonization was very quick, and after the first month, the values of abundance, species richness, diversity and evenness were similar in the experimental trays and in the reference area (yachting harbour). Although the multivariate analysis showed that the species composition differed between the trays and the reference area, there were no significant differences in recolonization of gross and fine sands, indicating that other factors different from the granulometry are modulating the recolonization patterns.

  20. Effects of the humeral tray component positioning for onlay reverse shoulder arthroplasty design: a biomechanical analysis.

    PubMed

    Berhouet, Julien; Kontaxis, Andreas; Gulotta, Lawrence V; Craig, Edward; Warren, Russel; Dines, Joshua; Dines, David

    2015-04-01

    Recent shoulder prostheses have introduced a concept of a universal humeral stem component platform that has an onlay humeral tray for the reverse total shoulder arthroplasty (RTSA). No studies have reported how humeral tray positioning can affect the biomechanics of RTSA. The Newcastle Shoulder Model was used to investigate the biomechanical effect of humeral tray positioning in the Biomet Comprehensive Total Shoulder System (Biomet, Warsaw, IN, USA) RTSA. Five humeral tray configuration positions were tested: no offset, and 5 mm offset in the anterior, posterior, medial, and lateral positions. Superior and inferior impingement were evaluated for abduction, scapular plane elevation, forward flexion, and external/internal rotation with the elbow at the side (adduction) and at 90° of shoulder abduction. Muscle lengths and moment arms (elevating and rotational) were calculated for the deltoid, the infraspinatus, the teres minor, and the subscapularis. Inferior impingement was not affected by the humeral tray position. There was less superior impingement during abduction, scapular plane elevation, and rotation with the shoulder when the tray was placed laterally or posteriorly. The subscapularis rotational moment arm was increased with a posterior offset, whereas infraspinatus and teres minor rotational moment arms were increased with an anterior offset. Very little change was observed for the deltoid elevating moment arm or for its muscle length. Positioning the humeral tray with posterior offset offers a biomechanical advantage for patients needing RTSA by decreasing superior impingement and increasing the internal rotational moment arm of the subscapularis, without creating inferior impingement. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  1. 30 CFR 77.601 - Trailing cables or portable cables; temporary splices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Trailing cables or portable cables; temporary... OF UNDERGROUND COAL MINES Trailing Cables § 77.601 Trailing cables or portable cables; temporary splices. Temporary splices in trailing cables or portable cables shall be made in a workmanlike manner and...

  2. Which Tibial Tray Design Achieves Maximum Coverage and Ideal Rotation: Anatomic, Symmetric, or Asymmetric? An MRI-based study.

    PubMed

    Stulberg, S David; Goyal, Nitin

    2015-10-01

    Two goals of tibial tray placement in TKA are to maximize coverage and establish proper rotation. Our purpose was to utilize MRI information obtained as part of PSI planning to determine the impact of tibial tray design on the relationship between coverage and rotation. MR images for 100 consecutive knees were uploaded into PSI software. Preoperative planning software was used to evaluate 3 different tray designs: anatomic, symmetric, and asymmetric. Approximately equally good coverage was achieved with all three trays. However, the anatomic compared to symmetric/asymmetric trays required less malrotation (0.3° vs 3.0/2.4°; P < 0.001), with a higher proportion of cases within 5° of neutral (97% vs 73/77%; P < 0.001). In this study, the anatomic tibia optimized the relationship between coverage and rotation. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Corn forage biological pretreatment by Trametes versicolor in a tray bioreactor.

    PubMed

    Planinić, Mirela; Zelić, Bruno; Čubel, Ivan; Bucić-Kojić, Ana; Tišma, Marina

    2016-08-01

    Trametes versicolor is a white-rot fungus known to be efficient in lignin removal due to its complex extracellular lignocellulolytic enzymatic system. Therefore, it can be used in the treatment of lignocellulose waste from agro, food, and wood industries. In a first experiment, corn forage treatment with T. versicolor was investigated in laboratory jars. In a second experiment, the process was scaled up to a tray bioreactor. In the tray bioreactor, the process of lignin degradation was improved, resulting in an increase in lignin conversion of up to 71% during seven days' treatment. © The Author(s) 2016.

  4. 30 CFR 75.607 - Breaking trailing cable and power cable connections.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Breaking trailing cable and power cable....607 Breaking trailing cable and power cable connections. [Statutory Provisions] Trailing cable and power cable connections to junction boxes shall not be made or broken under load. ...

  5. 30 CFR 75.607 - Breaking trailing cable and power cable connections.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Breaking trailing cable and power cable....607 Breaking trailing cable and power cable connections. [Statutory Provisions] Trailing cable and power cable connections to junction boxes shall not be made or broken under load. ...

  6. 30 CFR 75.607 - Breaking trailing cable and power cable connections.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Breaking trailing cable and power cable....607 Breaking trailing cable and power cable connections. [Statutory Provisions] Trailing cable and power cable connections to junction boxes shall not be made or broken under load. ...

  7. 30 CFR 75.607 - Breaking trailing cable and power cable connections.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Breaking trailing cable and power cable....607 Breaking trailing cable and power cable connections. [Statutory Provisions] Trailing cable and power cable connections to junction boxes shall not be made or broken under load. ...

  8. 30 CFR 75.607 - Breaking trailing cable and power cable connections.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Breaking trailing cable and power cable... LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Trailing Cables § 75.607 Breaking trailing cable and power cable connections. [Statutory Provisions] Trailing cable and...

  9. Coaxial cable stripping device facilitates RF cabling fabrication

    NASA Technical Reports Server (NTRS)

    Hughes, R. S.; Tobias, R. A.

    1967-01-01

    Coaxial cable stripping device assures clean, right angled shoulder for RF cable connector fabrication. This method requires minimal skill and creates a low voltage standing wave ratio and mechanical stability in the interconnecting RF Cables.

  10. STS-57 inflight maintenance (IFM) tool tray at Boeing FEPF bench review

    NASA Technical Reports Server (NTRS)

    1993-01-01

    STS-57 inflight maintenance (IFM) tool tray is displayed on a table top during the bench review at Boeing's Flight Equipment Processing Facility (FEPF) located near JSC. The tool tray will be located on Endeavour's, Orbiter Vehicle (OV) 105's, middeck in forward locker MF57K and includes pinch bar, deadblow hammer, punch, inspection mirror, speed handle assembly, robbins wrench, adjustable wrench, vise grips, connector pliers, ACCU bypass connector, connector strap wrench, locker tool, and mechanical fingers. Photo taken by NASA JSC contract photographer Benny Benavides.

  11. Sterility maintenance study: Dynamic evaluation of sterilized rigid containers and wrapped instrument trays to prevent bacterial ingress.

    PubMed

    Shaffer, Harry L; Harnish, Delbert A; McDonald, Michael; Vernon, Reid A; Heimbuch, Brian K

    2015-12-01

    Sterilized packaging systems are designed to maintain the sterility of surgical instruments and devices from the time of sterilization until use. This study evaluated the effectiveness of rigid containers versus wrapped instrument trays, sterilized using North American sterilization protocols, to maintain a sterile internal environment poststerilization when challenged with aerosolized bacteria under dynamic environmental conditions. Using a custom aerosol chamber, 111 rigid containers of various durations of use (unused, used <5 years, used 5-9 years) and 161 wrapped trays using 3 grades of sterilization wrap were challenged with ~10(2) colony-forming units per liter of air containing aerosolized Micrococcus luteus with a count median particle size of 1 μm, while simultaneously experiencing air volume exchanges due to vacuum cycles-two 1-psi cycles, three 0.7-psi cycles, and three 0.4-psi cycles-to simulate air exchange events occurring during the sterilization, transportation, and storage of sterilized instrument trays in health care facilities. Of 111 rigid containers tested, 97 (87%) demonstrated bacterial ingress into the container. Of 161 wrapped trays, 0 (0%) demonstrated bacterial ingress into the tray. Contamination rates of rigid containers increased significantly with increasing duration of use. In this study using a dynamic bacterial aerosol challenge, sterilized wrapped trays demonstrated significantly greater protection than sterilized rigid containers against the ingress of airborne bacteria. Copyright © 2015. Published by Elsevier Inc.

  12. Efficacy of Home-use Bleaching Agents Delivered in Customized or Prefilled Disposable Trays: A Randomized Clinical Trial.

    PubMed

    Carlos, N R; Bridi, E C; Amaral, Flb; França, Fmg; Turssi, C P; Basting, R T

    The purpose of this study was to evaluate bleaching methods containing hydrogen peroxide (HP) or carbamide peroxide (CP), dispensed in customized or prefilled trays, in terms of color change, tooth sensitivity, gingival irritation, acceptance, and comfort. Seventy-five volunteers were randomly selected and distributed according to the whitening agent (n=25): 10% HP dispensed in prefilled trays (Opalescence Go 10%) and 9.5% HP (Pola Day) and 10% CP both delivered in customized trays (Opalescence PF 10%). HP was applied for 30 min/d for 14 days (d), and CP for 8 h/d for 14 days. Evaluations were performed at baseline and at 7 days and 14 days of treatment. Color change was measured with Commission internationale de l'éclairage color coordinates (L*, a*, b*), Vita Classical, and 3D Master scales. A visual analog scale was used to assess tooth sensitivity, acceptance of the method and degree of comfort of the tray. Gingival irritation was evaluated as present or absent and localized or generalized. Regarding gingival irritation, tray acceptance, and tooth sensitivity, no differences were observed among the groups at any time (p>0.05). As for degree of comfort, 10% HP showed lower scores (comfortable) than 10% CP, with significant differences (p<0.05) from the other groups (comfortable to very comfortable). In terms of ΔL, Δa, and ΔE, no difference was observed among the groups or between the time periods (p>0.05). The Δb average was higher at 14 days (p<0.05), and there was no difference among the groups (p>0.05). Localized gingival irritation was observed in both tray methods. Mild tooth sensitivity was observed with time, regardless of the bleaching agent concentration or the application time. Color change was similar for all the groups at 7 days and 14 days, but there was a greater reduction in the yellow hue at 14 days. All the bleaching methods were highly accepted and effective in promoting whitening. Although prefilled trays are generally comfortable, they

  13. Cable Tester Box

    NASA Technical Reports Server (NTRS)

    Lee, Jason H.

    2011-01-01

    Cables are very important electrical devices that carry power and signals across multiple instruments. Any fault in a cable can easily result in a catastrophic outcome. Therefore, verifying that all cables are built to spec is a very important part of Electrical Integration Procedures. Currently, there are two methods used in lab for verifying cable connectivity. (1) Using a Break-Out Box and an ohmmeter this method is time-consuming but effective for custom cables and (2) Commercial Automated Cable Tester Boxes this method is fast, but to test custom cables often requires pre-programmed configuration files, and cables used on spacecraft are often uniquely designed for specific purposes. The idea is to develop a semi-automatic continuity tester that reduces human effort in cable testing, speeds up the electrical integration process, and ensures system safety. The JPL-Cable Tester Box is developed to check every single possible electrical connection in a cable in parallel. This system indicates connectivity through LED (light emitting diode) circuits. Users can choose to test any pin/shell (test node) with a single push of a button, and any other nodes that are shorted to the test node, even if they are in the same connector, will light up with the test node. The JPL-Cable Tester Boxes offers the following advantages: 1. Easy to use: The architecture is simple enough that it only takes 5 minutes for anyone to learn how operate the Cable Tester Box. No pre-programming and calibration are required, since this box only checks continuity. 2. Fast: The cable tester box checks all the possible electrical connections in parallel at a push of a button. If a cable normally takes half an hour to test, using the Cable Tester Box will improve the speed to as little as 60 seconds to complete. 3. Versatile: Multiple cable tester boxes can be used together. As long as all the boxes share the same electrical potential, any number of connectors can be tested together.

  14. Investigation of solid nitrogen for cryogenic thermal storage in superconducting cable terminations for enhanced resiliency

    NASA Astrophysics Data System (ADS)

    Suttell, N.; Zhang, Z.; Kweon, J.; Nes, T.; Kim, C. H.; Pamidi, S.; Ordonez, J. C.

    2017-12-01

    Low heat capacity of helium makes the helium gas cooled high temperature superconducting (HTS) power devices susceptible to large temperature rises during unexpected heat loads such as electrical faults or cryogenic system failures. Cryogenic thermal storage in the form of solid nitrogen designed in the terminations is explored as a means to increase the thermal stability and operational time of HTS power cables in the event of unexpected heat loads. An external tank containing activated charcoal is used as an adsorption buffer tank for nitrogen gas. The use of activated charcoal minimizes the volume of the buffer tank and prevents pressure rises during melting and boiling of the solid nitrogen. Calculations of the cryogenic thermal storage needed and a description of the experimental setup used to understand the design constraints are discussed.

  15. Robotic Vision, Tray-Picking System Design Using Multiple, Optical Matched Filters

    NASA Astrophysics Data System (ADS)

    Leib, Kenneth G.; Mendelsohn, Jay C.; Grieve, Philip G.

    1986-10-01

    The optical correlator is applied to a robotic vision, tray-picking problem. Complex matched filters (MFs) are designed to provide sufficient optical memory for accepting any orientation of the desired part, and a multiple holographic lens (MHL) is used to increase the memory for continuous coverage. It is shown that with appropriate thresholding a small part can be selected using optical matched filters. A number of criteria are presented for optimizing the vision system. Two of the part-filled trays that Mendelsohn used are considered in this paper which is the analog (optical) expansion of his paper. Our view in this paper is that of the optical correlator as a cueing device for subsequent, finer vision techniques.

  16. [The geometry of the keel determines the behaviour of the tibial tray against torsional forces in total knee replacement].

    PubMed

    García David, S; Cortijo Martínez, J A; Navarro Bermúdez, I; Maculé, F; Hinarejos, P; Puig-Verdié, L; Monllau, J C; Hernández Hermoso, J A

    2014-01-01

    The keel design of the tibial tray is essential for the transmission of the majority of the forces to the peripheral bone structures, which have better mechanical proprieties, thus reducing the risk of loosening. The aim of the present study was to compare the behaviour of different tibial tray designs submitted to torsional forces. Four different tibial components were modelled. The 3-D reconstruction was made using the Mimics software. The solid elements were generated by SolidWorks. The finite elements study was done by Unigraphics. A torsional force of 6 Nm. applied to the lateral aspects of each tibial tray was simulated. The GENUTECH® tibial tray, with peripheral trabecular bone support, showed a lower displacement and less transmitted tensions under torsional forces. The results suggest that a tibial tray with more peripheral support behaves mechanically better than the other studied designs. Copyright © 2013 SECOT. Published by Elsevier Espana. All rights reserved.

  17. Superconductor cable

    DOEpatents

    Allais, Arnaud; Schmidt, Frank; Marzahn, Erik

    2010-05-04

    A superconductor cable is described, having a superconductive flexible cable core (1) , which is laid in a cryostat (2, 3, 4), in which the cable core (1) runs in the cryostat (2, 3, 4) in the form of a wave or helix at room temperature.

  18. Superconducting ac cable

    NASA Astrophysics Data System (ADS)

    Schmidt, F.

    1980-11-01

    The components of a superconducting 110 kV ac cable for power ratings or = 2000 MVA were developed. The cable design is of the semiflexible type, with a rigid cryogenic envelope containing a flexible hollow coaxial cable core. The cable core consists of spirally wound Nb-A1 composite wires electrically insulated by high pressure polyethylene tape wrappings. A 35 m long single phase test cable with full load terminals rated at 110 kV and 10 kA was constructed and successfully tested. The results obtained prove the technical feasibility and capability of this cable design.

  19. Static and Dynamic Characteristics of a Long-Span Cable-Stayed Bridge with CFRP Cables

    PubMed Central

    Xie, Xu; Li, Xiaozhang; Shen, Yonggang

    2014-01-01

    In this study, the scope of CFRP cables in cable-stayed bridges is studied by establishing a numerical model of a 1400-m span of the same. The mechanical properties and characteristics of CFRP stay cables and of a cable-stayed bridge with CFRP cables are here subjected to comprehensive analysis. The anomalies in the damping properties of free vibration, nonlinear parametric vibration and wind fluctuating vibration between steel cables and CFRP cables are determined. The structural stiffness, wind resistance and traffic vibration of the cable-stayed bridge with CFRP cables are also analyzed. It was found that the static performances of a cable-stayed bridge with CFRP cables and steel cables are basically the same. The natural frequencies of CFRP cables do not coincide with the major natural frequencies of the cable-stayed bridge, so the likelihood of CFRP cable-bridge coupling vibration is minuscule. For CFRP cables, the response amplitudes of both parametric vibration and wind fluctuating vibration are smaller than those of steel cables. It can be concluded from the research that the use of CFRP cables does not change the dynamic characteristics of the vehicle-bridge coupling vibration. Therefore, they can be used in long-span cable-stayed bridges with an excellent mechanical performance. PMID:28788710

  20. Static and Dynamic Characteristics of a Long-Span Cable-Stayed Bridge with CFRP Cables.

    PubMed

    Xie, Xu; Li, Xiaozhang; Shen, Yonggang

    2014-06-23

    In this study, the scope of CFRP cables in cable-stayed bridges is studied by establishing a numerical model of a 1400-m span of the same. The mechanical properties and characteristics of CFRP stay cables and of a cable-stayed bridge with CFRP cables are here subjected to comprehensive analysis. The anomalies in the damping properties of free vibration, nonlinear parametric vibration and wind fluctuating vibration between steel cables and CFRP cables are determined. The structural stiffness, wind resistance and traffic vibration of the cable-stayed bridge with CFRP cables are also analyzed. It was found that the static performances of a cable-stayed bridge with CFRP cables and steel cables are basically the same. The natural frequencies of CFRP cables do not coincide with the major natural frequencies of the cable-stayed bridge, so the likelihood of CFRP cable-bridge coupling vibration is minuscule. For CFRP cables, the response amplitudes of both parametric vibration and wind fluctuating vibration are smaller than those of steel cables. It can be concluded from the research that the use of CFRP cables does not change the dynamic characteristics of the vehicle-bridge coupling vibration. Therefore, they can be used in long-span cable-stayed bridges with an excellent mechanical performance.

  1. System for stabilizing cable phase delay utilizing a coaxial cable under pressure

    NASA Technical Reports Server (NTRS)

    Clements, P. A. (Inventor)

    1974-01-01

    Stabilizing the phase delay of signals passing through a pressurizable coaxial cable is disclosed. Signals from an appropriate source at a selected frequency, e.g., 100 MHz, are sent through the controlled cable from a first cable end to a second cable end which, electrically, is open or heavily mismatched at 100 MHz, thereby reflecting 100 MHz signals back to the first cable end. Thereat, the phase difference between the reflected-back signals and the signals from the source is detected by a phase detector. The output of the latter is used to control the flow of gas to or from the cable, thereby controlling the cable pressure, which in turn affects the cable phase delay.

  2. Cable Television.

    ERIC Educational Resources Information Center

    Federal Communications Commission, Washington, DC.

    The Federal Communications Commission (FCC) presents a brief description of cable television and explains some basic regulations pertaining to it. The history of cable regulation covers the initial jurisdiction, economic considerations of the regulation, court tests, and the holding of public hearings. The major provisions of new cable rules are…

  3. Cable compliance

    NASA Technical Reports Server (NTRS)

    Kerley, J.; Eklund, W.; Burkhardt, R.; Rossoni, P.

    1992-01-01

    The object of the investigation was to solve mechanical problems using cable-in-bending and cable-in-torsion. These problems included robotic contacts, targets, and controls using cable compliance. Studies continued in the use of cable compliance for the handicapped and the elderly. These included work stations, walkers, prosthetic knee joints, elbow joints, and wrist joints. More than half of these objects were met, and models were made and studies completed on most of the others. It was concluded that the many different and versatile solutions obtained only opened the door to many future challenges.

  4. 12. COLD CALIBRATION BLOCKHOUSE BASEMENT VIEW FROM LEFT TO RIGHT, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. COLD CALIBRATION BLOCKHOUSE BASEMENT VIEW FROM LEFT TO RIGHT, CABLE TRAYS, RACKS, CABLE CONNECTION TERMINALS. - Marshall Space Flight Center, East Test Area, Cold Calibration Test Stand, Huntsville, Madison County, AL

  5. Training to Increase Safe Tray Carrying among Cocktail Servers

    ERIC Educational Resources Information Center

    Scherrer, Megan D.; Wilder, David A.

    2008-01-01

    We evaluated the effects of training on proper carrying techniques among 3 cocktail servers to increase safe tray carrying on the job and reduce participants' risk of developing musculoskeletal disorders. As participants delivered drinks to their tables, their finger, arm, and neck positions were observed and recorded. Each participant received…

  6. Cable Economics.

    ERIC Educational Resources Information Center

    Cable Television Information Center, Washington, DC.

    A guide to the economic factors that influence cable television systems is presented. Designed for local officials who must have some familiarity with cable operations in order to make optimum decisions, the guide analyzes the financial framework of a cable system, not only from the operators viewpoint, but also from the perspective of the…

  7. Cable load sensing device

    DOEpatents

    Beus, Michael J.; McCoy, William G.

    1998-01-01

    Apparatus for sensing the magnitude of a load on a cable as the cable is employed to support the load includes a beam structure clamped to the cable so that a length of the cable lies along the beam structure. A spacer associated with the beam structure forces a slight curvature in a portion of the length of cable under a cable "no-load" condition so that the portion of the length of cable is spaced from the beam structure to define a cable curved portion. A strain gauge circuit including strain gauges is secured to the beam structure by welding. As the cable is employed to support a load the load causes the cable curved portion to exert a force normal to the cable through the spacer and on the beam structure to deform the beam structure as the cable curved portion attempts to straighten under the load. As this deformation takes place, the resistance of the strain gauges is set to a value proportional to the magnitude of the normal strain on the beam structure during such deformation. The magnitude of the normal strain is manipulated in a control device to generate a value equal to the magnitude or weight of the load supported by the cable.

  8. Universal Cable Brackets

    NASA Technical Reports Server (NTRS)

    Vanvalkenburgh, C.

    1985-01-01

    Concept allows routing easily changed. No custom hardware required in concept. Instead, standard brackets cut to length and installed at selected locations along cable route. If cable route is changed, brackets simply moved to new locations. Concept for "universal" cable brackets make it easy to route electrical cable around and through virtually any structure.

  9. Multistrand superconductor cable

    DOEpatents

    Borden, Albert R.

    1985-01-01

    Improved multistrand Rutherford-type superconductor cable is produced by using strands which are preformed, prior to being wound into the cable, so that each strand has a variable cross section, with successive portions having a substantially round cross section, a transitional oval cross section, a rectangular cross section, a transitional oval cross section, a round cross section and so forth, in repetitive cycles along the length of the strand. The cable is wound and flattened so that the portions of rectangular cross section extend across the two flat sides of the cable at the strand angle. The portions of round cross section are bent at the edges of the flattened cable, so as to extend between the two flat sides. The rectangular portions of the strands slide easily over one another, so as to facilitate flexing and bending of the cable, while also minimizing the possibility of causing damage to the strands by such flexing or bending. Moreover, the improved cable substantially maintains its compactness and cross-sectional shape when the cable is flexed or bent.

  10. Comparative rice seed toxicity tests using filter paper, growth pouch-tm, and seed tray methods

    USGS Publications Warehouse

    Wang, W.

    1993-01-01

    Paper substrate, especially circular filter paper placed inside a Petri dish, has long been used for the plant seed toxicity test (PSTT). Although this method is simple and inexpensive, recent evidence indicates that it gives results that are significantly different from those obtained using a method that does not involve paper, especially when testing metal cations. The study compared PSTT using three methods: filter paper, Growth Pouch-TM, and seed tray. The Growth Pouch-TM is a commercially available device. The seed tray is a newly designed plastic receptacle placed inside a Petri dish. The results of the Growth Pouch-TM method showed no toxic effects on rice for Ag up to 40 mg L-1 and Cd up to 20 mg L-1. Using the seed tray method, IC50 (50% inhibitory effect concentration) values were 0.55 and 1.4 mg L-1 for Ag and Cd, respectively. Although results of filter paper and seed tray methods were nearly identical for NaF, Cr(VI), and phenol, the toxicities of cations Ag and Cd were reduced by using the filter paper method; IC50 values were 22 and 18 mg L-1, respectively. The results clearly indicate that paper substrate is not advisable for PSTT.

  11. Fabrication of customized sectional impression trays in management of patients with limited mouth opening: a simple and unique approach.

    PubMed

    Krishna Ch, Vamsi; Mahendranadh Reddy, K; Gupta, Nidhi; Mahadev Shastry, Y; Chandra Sekhar, N; Aditya, Venkat; Reddy, G V K Mohan

    2013-01-01

    Impression making is not only important but is also the most significant step in the fabrication of any fixed or removable prosthesis. Proper impression making may be hindered by certain pathologic conditions. Reduced mouth opening is one of the common mechanical obstructions for proper orientation of the impression tray in the patient's mouth. In patients with trismus induced by submucous fibrosis, the procedure may be even more difficult to carry out because of reduced tissue resiliency and obliteration of vestibular spaces. Use of sectional trays offers one of the alternatives to overcome the problem of restricted mouth opening. Fabrication of customized impression trays according to the patient dentition improves the accuracy of impression making. The present case reports describe the fabrication of sectional custom trays designed for dentulous patients with chronic tobacco-induced submucous fibrosis.

  12. Braided tubular superelastic cables provide improved spinal stability compared to multifilament sublaminar cables.

    PubMed

    Tremblay, Jaëlle; Mac-Thiong, Jean-Marc; Brailovski, Vladimir; Petit, Yvan

    2015-09-01

    This study investigates the use of braided tubular superelastic cables, previously used for sternum closure following sternotomy, as sublaminar fixation method. It compares the biomechanical performance of spinal instrumentation fixation systems with regular sublaminar cables and proprietary superelastic cables. A hybrid experimental protocol was applied to six porcine L1-L4 spinal segments to compare multifilament sublaminar cables (Atlas, Medtronic Sofamor Danek, Memphis, TN) with proprietary superelastic cables. First, intact total range of motion was determined for all specimens using pure moment loading. Second, pure moments were imposed to the instrumented specimens until these intact total ranges of motion were reproduced. Compared to the intact specimens, the use of superelastic cables resulted in stiffer instrumented specimens than the use of multifilament cables for all the loading modes except axial torsion. Consequently, the superelastic cables limited the instrumented segments mobility more than the multifilament cables. Spinal instrumentation fixation systems using superelastic cables could be a good alternative to conventional sublaminar cables as it maintains a constant stabilization of the spine during loading. © IMechE 2015.

  13. STS-57 inflight maintenance (IFM) tool tray at Boeing FEPF bench review

    NASA Technical Reports Server (NTRS)

    1993-01-01

    STS-57 inflight maintenance (IFM) tool tray is displayed on a table top during the bench review at Boeing's Flight Equipment Processing Facility (FEPF) located near JSC. The tool tray will be located on Endeavour's, Orbiter Vehicle (OV) 105's, middeck in forward locker MF57K and includes modified forceps, L-shaped hex wrenches, jeweler screwdrivers, adjustable wrench, bone saw, combination wrenches, override devices, switch guards, tape measure, torque driver, short screwdriver, long screwdriver, phillips screwdrivers, ratchet wrench, needlenose pliers, torque tips, adapter, universal joint, deepwell sockets, sockets, driver handle, seat adjustment tool, extensions, torque wrench, allen head drivers, hacksaw, and blades. Photo taken by NASA JSC contract photographer Benny Benavides.

  14. Fiber optic submarine cables cuts cost modeling and cable protection aspects

    NASA Astrophysics Data System (ADS)

    Al-Lawati, Ali

    2015-03-01

    This work presents a model to calculate costs associated with submarine fiber optic cable cuts. It accounts for both fixed and variable factors determining cost of fixing cables and restoring data transmission. It considers duration of a cut, capacity of fibers, number of fiber pairs and expected number of cuts during cable life time. Moreover, it provides templates for initial feasibility assessments by comparing cut costs to cost of different cable protection schemes. It offers a needed tool to assist in guiding decision makers in selecting type of cable, length and depth of cable burial in terms of increase in initial investment due to adapting such protection methods, and compare it to cost of cuts repair and alternative restoration paths for data.

  15. Superconductor cable

    DOEpatents

    Allais, Arnaud [Hannover, DE; Schmidt, Frank [Langenhagen, DE

    2009-12-15

    A superconductor cable includes a superconductive cable core (1) and a cryostat (2) enclosing the same. The cable core (1) has a superconductive conductor (3), an insulation (4) surrounding the same and a shielding (5) surrounding the insulation (4). A layer (3b) of a dielectric or semiconducting material is applied to a central element (3a) formed from a normally conducting material as a strand or tube and a layer (3c) of at least one wire or strip of superconductive material is placed helically on top. The central element (3a) and the layer (3c) are connected to each other in an electrically conducting manner at the ends of the cable core (1).

  16. Cable equation for general geometry

    NASA Astrophysics Data System (ADS)

    López-Sánchez, Erick J.; Romero, Juan M.

    2017-02-01

    The cable equation describes the voltage in a straight cylindrical cable, and this model has been employed to model electrical potential in dendrites and axons. However, sometimes this equation might give incorrect predictions for some realistic geometries, in particular when the radius of the cable changes significantly. Cables with a nonconstant radius are important for some phenomena, for example, discrete swellings along the axons appear in neurodegenerative diseases such as Alzheimers, Parkinsons, human immunodeficiency virus associated dementia, and multiple sclerosis. In this paper, using the Frenet-Serret frame, we propose a generalized cable equation for a general cable geometry. This generalized equation depends on geometric quantities such as the curvature and torsion of the cable. We show that when the cable has a constant circular cross section, the first fundamental form of the cable can be simplified and the generalized cable equation depends on neither the curvature nor the torsion of the cable. Additionally, we find an exact solution for an ideal cable which has a particular variable circular cross section and zero curvature. For this case we show that when the cross section of the cable increases the voltage decreases. Inspired by this ideal case, we rewrite the generalized cable equation as a diffusion equation with a source term generated by the cable geometry. This source term depends on the cable cross-sectional area and its derivates. In addition, we study different cables with swelling and provide their numerical solutions. The numerical solutions show that when the cross section of the cable has abrupt changes, its voltage is smaller than the voltage in the cylindrical cable. Furthermore, these numerical solutions show that the voltage can be affected by geometrical inhomogeneities on the cable.

  17. Comparison study of cable geometries and superconducting tape layouts for high-temperature superconductor cables

    NASA Astrophysics Data System (ADS)

    Ta, Wurui; Shao, Tianchong; Gao, Yuanwen

    2018-04-01

    High-temperature superconductor (HTS) rare-earth-barium-copper-oxide (REBCO) tapes are very promising for use in high-current cables. The cable geometry and the layout of the superconducting tapes are directly related to the performance of the HTS cable. In this paper, we use numerical methods to perform a comparison study of multiple-stage twisted stacked-tape cable (TSTC) conductors to find better cable structures that can both improve the critical current and minimize the alternating current (AC) losses of the cable. The sub-cable geometry is designed to have a stair-step shape. Three superconducting tape layouts are chosen and their transport performance and AC losses are evaluated. The magnetic field and current density profiles of the cables are obtained. The results show that arrangement of the superconducting tapes from the interior towards the exterior of the cable based on their critical current values in descending order can enhance the cable's transport capacity while significantly reducing the AC losses. These results imply that cable transport capacity improvements can be achieved by arranging the superconducting tapes in a manner consistent with the electromagnetic field distribution. Through comparison of the critical currents and AC losses of four types of HTS cables, we determine the best structural choice among these cables.

  18. 40. Coffee bean drying trays that are stored in racks ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    40. Coffee bean drying trays that are stored in racks under building and pulled out to sun dry beans on terraces to the north and south of building. HAER PR, 6-MAGU, 1C-3 - Hacienda Buena Vista, PR Route 10 (Ponce to Arecibo), Magueyes, Ponce Municipio, PR

  19. Cable-fault locator

    NASA Technical Reports Server (NTRS)

    Cason, R. L.; Mcstay, J. J.; Heymann, A. P., Sr.

    1979-01-01

    Inexpensive system automatically indicates location of short-circuited section of power cable. Monitor does not require that cable be disconnected from its power source or that test signals be applied. Instead, ground-current sensors are installed in manholes or at other selected locations along cable run. When fault occurs, sensors transmit information about fault location to control center. Repair crew can be sent to location and cable can be returned to service with minimum of downtime.

  20. Cable and Line Inspection Mechanism

    NASA Technical Reports Server (NTRS)

    Ross, Terence J. (Inventor)

    2003-01-01

    An automated cable and line inspection mechanism visually scans the entire surface of a cable as the mechanism travels along the cable=s length. The mechanism includes a drive system, a video camera, a mirror assembly for providing the camera with a 360 degree view of the cable, and a laser micrometer for measuring the cable=s diameter. The drive system includes an electric motor and a plurality of drive wheels and tension wheels for engaging the cable or line to be inspected, and driving the mechanism along the cable. The mirror assembly includes mirrors that are positioned to project multiple images of the cable on the camera lens, each of which is of a different portion of the cable. A data transceiver and a video transmitter are preferably employed for transmission of video images, data and commands between the mechanism and a remote control station.

  1. Cable and line inspection mechanism

    NASA Technical Reports Server (NTRS)

    Ross, Terence J. (Inventor)

    2003-01-01

    An automated cable and line inspection mechanism visually scans the entire surface of a cable as the mechanism travels along the cable=s length. The mechanism includes a drive system, a video camera, a mirror assembly for providing the camera with a 360 degree view of the cable, and a laser micrometer for measuring the cable=s diameter. The drive system includes an electric motor and a plurality of drive wheels and tension wheels for engaging the cable or line to be inspected, and driving the mechanism along the cable. The mirror assembly includes mirrors that are positioned to project multiple images of the cable on the camera lens, each of which is of a different portion of the cable. A data transceiver and a video transmitter are preferably employed for transmission of video images, data and commands between the mechanism and a remote control station.

  2. 1. Credit BG. View looking southeast down onto roof and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Credit BG. View looking southeast down onto roof and the north and west facades of Steam Generator Plant, Building 4280/E-81. Vents on roof were from gas-fired steam generators. Pipes emerging from north facade are for steam. Elevated narrow tray is for electrical cables. To lower left of image (immediate north of 4280/E-81) is concrete-lined pond originally built to neutralize rocket engine exhaust compounds; it was only used as a cooling pond. To the lower right of this image are concrete pads which held two 7,500 gallon feedwater tanks for the boilers in 4280/E-81; these tanks were transferred to another federal space science organization and removed from the JPL compound in 1994. Beyond 4280/E-81 to the upper left is a reclamation pond. ... - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Steam Generator Plant, Edwards Air Force Base, Boron, Kern County, CA

  3. Parametrically excited oscillation of stay cable and its control in cable-stayed bridges.

    PubMed

    Sun, Bing-nan; Wang, Zhi-gang; Ko, J M; Ni, Y Q

    2003-01-01

    This paper presents a nonlinear dynamic model for simulation and analysis of a kind of parametrically excited vibration of stay cable caused by support motion in cable-stayed bridges. The sag, inclination angle of the stay cable are considered in the model, based on which, the oscillation mechanism and dynamic response characteristics of this kind of vibration are analyzed through numerical calculation. It is noted that parametrically excited oscillation of a stay cable with certain sag, inclination angle and initial static tension force may occur in cable-stayed bridges due to deck vibration under the condition that the natural frequency of a cable approaches to about half of the first model frequency of the bridge deck system. A new vibration control system installed on the cable anchorage is proposed as a possible damping system to suppress the cable parametric oscillation. The numerical calculation results showed that with the use of this damping system, the cable oscillation due to the vibration of the deck and/or towers will be considerably reduced.

  4. Electronically controlled cable wrapper

    DOEpatents

    Young, Thomas M.

    1984-01-01

    A spindle assembly engages and moves along a length of cable to be wrapped with insulating tape. Reels of insulating tape are mounted on a outer rotatable spindle which revolves around the cable to dispense insulating tape. The rate of movement of the spindle assembly along the length of the cable is controlled by a stepper motor which is programmably synchronized to the rate at which rotatable spindle wraps the cable. The stepper motor drives a roller which engages the cable and moves the spindle assembly along the length of the cable as it is being wrapped. The spindle assembly is mounted at the end of an articulated arm which allows free movement of the spindle assembly and allows the spindle assembly to follow lateral movement of the cable.

  5. Electronically controlled cable wrapper

    DOEpatents

    Young, T.M.

    1982-08-17

    A spindle assembly engages and moves along a length of cable to be wrapped with insulating tape. Reels of insulating tape are mounted on a outer rotatable spindle which revolves around the cable to dispense insulating tape. The rate of movement of the spindle assembly along the length of the cable is controlled by a stepper motor which is programmably synchronized to the rate at which rotatable spindle wraps the cable. The stepper motor drives a roller which engages the cable and moves the spindle assembly along the length of the cable as it is being wrapped. The spindle assembly is mounted at the end of an articulated arm which allows free movement of the spindle assembly and allows the spindle assembly to follow lateral movement of the cable.

  6. A New Multiconstraint Method for Determining the Optimal Cable Stresses in Cable-Stayed Bridges

    PubMed Central

    Asgari, B.; Osman, S. A.; Adnan, A.

    2014-01-01

    Cable-stayed bridges are one of the most popular types of long-span bridges. The structural behaviour of cable-stayed bridges is sensitive to the load distribution between the girder, pylons, and cables. The determination of pretensioning cable stresses is critical in the cable-stayed bridge design procedure. By finding the optimum stresses in cables, the load and moment distribution of the bridge can be improved. In recent years, different research works have studied iterative and modern methods to find optimum stresses of cables. However, most of the proposed methods have limitations in optimising the structural performance of cable-stayed bridges. This paper presents a multiconstraint optimisation method to specify the optimum cable forces in cable-stayed bridges. The proposed optimisation method produces less bending moments and stresses in the bridge members and requires shorter simulation time than other proposed methods. The results of comparative study show that the proposed method is more successful in restricting the deck and pylon displacements and providing uniform deck moment distribution than unit load method (ULM). The final design of cable-stayed bridges can be optimised considerably through proposed multiconstraint optimisation method. PMID:25050400

  7. A new multiconstraint method for determining the optimal cable stresses in cable-stayed bridges.

    PubMed

    Asgari, B; Osman, S A; Adnan, A

    2014-01-01

    Cable-stayed bridges are one of the most popular types of long-span bridges. The structural behaviour of cable-stayed bridges is sensitive to the load distribution between the girder, pylons, and cables. The determination of pretensioning cable stresses is critical in the cable-stayed bridge design procedure. By finding the optimum stresses in cables, the load and moment distribution of the bridge can be improved. In recent years, different research works have studied iterative and modern methods to find optimum stresses of cables. However, most of the proposed methods have limitations in optimising the structural performance of cable-stayed bridges. This paper presents a multiconstraint optimisation method to specify the optimum cable forces in cable-stayed bridges. The proposed optimisation method produces less bending moments and stresses in the bridge members and requires shorter simulation time than other proposed methods. The results of comparative study show that the proposed method is more successful in restricting the deck and pylon displacements and providing uniform deck moment distribution than unit load method (ULM). The final design of cable-stayed bridges can be optimised considerably through proposed multiconstraint optimisation method.

  8. A Comparative Evaluation of Accuracy of the Dies Affected by Tray Type, Material Viscosity, and Pouring Sequence of Dual and Single Arch Impressions- An In vitro Study

    PubMed Central

    Kulkarni, Rahul S.; Shah, Rupal J.; Chhajlani, Rahul; Saklecha, Bhuwan; Maru, Kavita

    2017-01-01

    Introduction The clinician’s skill, impression techniques, and materials play a very important role in recording fine details in an impression for accuracy of fixed partial denture prosthesis. Impression of prepared teeth and of the opposing arch can be recorded simultaneously by dual-arch trays, while the full arch metal trays are used for impressions of prepared teeth in one arch. Aim To measure and compare the accuracy of working dies made from impressions with metal and plastic dual arch trays and metal full arch trays, for two viscosities of impression material and by changing the sequence of pour of working and non-working sides. Materials and Methods A balanced design with independent samples was used to study the three variables (tray type, impression material viscosity, and pouring sequence). An impression made by dual arch trays and single arch trays were divided in to three groups (Group A-plastic dual arch tray, Group B-metal dual arch tray, Group C-full arch metal stock tray). Out of these three groups, two groups (Group A and B) were subdivided in to four subgroups each and one group (Group C) was subdivided in to two subgroups. A sample size of 30 was used in each subgroup yielding a total 300 impressions in three groups or ten subgroups. Impressions were made of a machined circular stainless steel die. All three dimensions (Occlusogingival, Mesiodistal, and Buccolingual) of the working dies as well as stainless steel standard die were measured three times, and the mean was used for the three standard sample values to which all working dies means were compared. Statistical analysis used for this study was a 3-factor analysis of variance with hypothesis testing at α =0.05. Results With respect to the selection of impression material viscosity statistically significant differences were found in the dies for the buccolingual and mesiodistal dimensions. Metal dual arch trays were slightly more accurate in the mesiodistal dimension in comparison to the

  9. Multistrand superconductor cable

    DOEpatents

    Borden, A.R.

    1984-03-08

    Improved multistrand Rutherford-type superconductor cable is produced by using strands which are preformed, prior to being wound into the cable, so that each strand has a variable cross section, with successive portions having a substantially round cross section, a transitional oval cross section, a rectangular cross section, a transitional oval cross section, a round cross section and so forth, in repetitive cycles along the length of the strand. The cable is wound and flattened so that the portions of rectangular cross section extend across the two flat sides of the cable at the strand angle. The portions of round cross section are bent at the edges of the flattened cable, so as to extend between the two flat sides. The rectangular portions of the strands slide easil

  10. Simulation of the cabling process for Rutherford cables: An advanced finite element model

    NASA Astrophysics Data System (ADS)

    Cabanes, J.; Garlasche, M.; Bordini, B.; Dallocchio, A.

    2016-12-01

    In all existing large particle accelerators (Tevatron, HERA, RHIC, LHC) the main superconducting magnets are based on Rutherford cables, which are characterized by having: strands fully transposed with respect to the magnetic field, a significant compaction that assures a large engineering critical current density and a geometry that allows efficient winding of the coils. The Nb3Sn magnets developed in the framework of the HL-LHC project for improving the luminosity of the Large Hadron Collider (LHC) are also based on Rutherford cables. Due to the characteristics of Nb3Sn wires, the cabling process has become a crucial step in the magnet manufacturing. During cabling the wires experience large plastic deformations that strongly modify the geometrical dimensions of the sub-elements constituting the superconducting strand. These deformations are particularly severe on the cable edges and can result in a significant reduction of the cable critical current as well as of the Residual Resistivity Ratio (RRR) of the stabilizing copper. In order to understand the main parameters that rule the cabling process and their impact on the cable performance, CERN has developed a 3D Finite Element (FE) model based on the LS-Dyna® software that simulates the whole cabling process. In the paper the model is presented together with a comparison between experimental and numerical results for a copper cable produced at CERN.

  11. DC Cable for Railway

    NASA Astrophysics Data System (ADS)

    Tomita, Masaru

    The development of a superconducting cable for railways has commenced, assuming that a DC transmission cable will be used for electric trains. The cable has been fabricated based on the results of current testing of a superconducting wire, and various evaluation tests have been performed to determine the characteristics of the cable. A superconducting transmission cable having zero electrical resistance and suitable for railway use is expected to enhance regeneration efficiency, reduce power losses, achieve load leveling and integration of sub-stations, and reduce rail potential.

  12. Coaxial cable connector

    NASA Technical Reports Server (NTRS)

    Caro, Edward R. (Inventor); Bonazza, Walter J. (Inventor)

    1987-01-01

    A coaxial cable connector is provided, which resists radio frequency breakdown in coaxial cables used in the vacuum of outer space. The connector body surrounds an insulator which includes an easily compressible elastomeric portion. An insulated coaxial cable is prepared so that its insulation projects beyond the outer conductor and compresses the elastomeric portion of the connector insulator.

  13. Noise from implantable Cooper cable.

    PubMed

    Carrington, V; Zhou, L; Donaldson, N

    2005-09-01

    Cooper cable is made for implanted devices, usually for connection to stimulating electrodes. An experiment has been performed to see whether these cables would be satisfactory for recording electroneurogram (ENG) signals from cuffs. Four cables were subjected to continuous flexion at 2 Hz while submerged in saline. The cables were connected to a low-noise amplifier, and the noise was measured using a spectrum analyser. These cables had not fractured after 184 million flexions, and the noise in the neural band (500-5000 Hz) had not increased owing to age. Noise in the ENG band increased by less than 3 dB owing to the motion. A fifth, worn cable did fail during the experiment, the conductors becoming exposed to the saline, but this was only apparent by extra noise when the cable was in motion. After 184 million flexions, the four cables were given a more severe test: instead of being connected to the amplifier reference node, two of the four cores of each cable were connected to 18V batteries. Two of the cables were then noisier, but only when in motion, presumably because of leakage between cores. Cooper cables are excellent for transmitting neural signals alone; transmission in one cable of neural signals and power supplies should be avoided if possible.

  14. Cable Tensiometer for Aircraft

    NASA Technical Reports Server (NTRS)

    Nunnelee, Mark (Inventor)

    2008-01-01

    The invention is a cable tensiometer that can be used on aircraft for real-time, in-flight cable tension measurements. The invention can be used on any aircraft cables with high precision. The invention is extremely light-weight, hangs on the cable being tested and uses a dual bending beam design with a high mill-volt output to determine tension.

  15. The thermal regime around buried submarine high-voltage cables

    NASA Astrophysics Data System (ADS)

    Emeana, C. J.; Hughes, T. J.; Dix, J. K.; Gernon, T. M.; Henstock, T. J.; Thompson, C. E. L.; Pilgrim, J. A.

    2016-08-01

    The expansion of offshore renewable energy infrastructure and the need for trans-continental shelf power transmission require the use of submarine high-voltage (HV) cables. These cables have maximum operating surface temperatures of up to 70 °C and are typically buried 1-2 m beneath the seabed, within the wide range of substrates found on the continental shelf. However, the heat flow pattern and potential effects on the sedimentary environments around such anomalously high heat sources in the near-surface sediments are poorly understood. We present temperature measurements from a 2-D laboratory experiment representing a buried submarine HV cable, and identify the thermal regimes generated within typical unconsolidated shelf sediments—coarse silt, fine sand and very coarse sand. We used a large (2 × 2.5 m2) tank filled with water-saturated spherical glass beads (ballotini) and instrumented with a buried heat source and 120 thermocouples to measure the time-dependent 2-D temperature distributions. The observed and corresponding Finite Element Method simulations of the steady state heat flow regimes and normalized radial temperature distributions were assessed. Our results show that the heat transfer and thus temperature fields generated from submarine HV cables buried within a range of sediments are highly variable. Coarse silts are shown to be purely conductive, producing temperature increases of >10 °C up to 40 cm from the source of 60 °C above ambient; fine sands demonstrate a transition from conductive to convective heat transfer between cf. 20 and 36 °C above ambient, with >10 °C heat increases occurring over a metre from the source of 55 °C above ambient; and very coarse sands exhibit dominantly convective heat transfer even at very low (cf. 7 °C) operating temperatures and reaching temperatures of up to 18 °C above ambient at a metre from the source at surface temperatures of only 18 °C. These findings are important for the surrounding near

  16. Improved models of cable-to-post attachments for high-tension cable barriers.

    DOT National Transportation Integrated Search

    2012-05-01

    Computer simulation models were developed to analyze and evaluate a new cable-to-post attachment for high-tension cable : barriers. The models replicated the performance of a keyway bolt currently used in the design of a high-tension cable : median b...

  17. Fire related hazards of cables: The Canadian position development of fire resistant inside wiring cable

    NASA Astrophysics Data System (ADS)

    Hartley, M. D.; Jaques, R. E.

    1986-11-01

    The Canadian Electrical Code and the National Building Code in Canada recognize only two designations in regards to fire resistance of cables; cables for use in combustible (residential) buildings and cables for use in non-combustible buildings. The Test standard for cables for non-combustible buildings resembles IEEE-383. However, it is more severe; particularly for small nonarmoured cables such as Inside Wiring Cable. This forthcoming requirement has necessitated material and product development. Although an Inside Wiring cable modification of both insulation and jacket was undertaken, the large volume fraction of combustible material in the jacket vis a vis the insulation made it the area of greatest impact. The paper outlines the development and its effect on cable performance.

  18. Closeup of LDEF experiment trays documented during STS-32 photo survey

    NASA Image and Video Library

    1990-01-20

    Closeup of Long Duration Exposure Facility (LDEF) experiment trays is documented during STS-32 retrieval activity and photo survey conducted by crewmembers onboard Columbia, Orbiter Vehicle (OV) 102. Partially visible is the Polymer Matrix Composite Materials Experiment. In the background is the surface of the Earth.

  19. Method to improve superconductor cable

    DOEpatents

    Borden, A.R.

    1984-03-08

    A method is disclosed of making a stranded superconductor cable having improved flexing and bending characteristics. In such method, a plurality of superconductor strands are helically wound around a cylindrical portion of a mandrel which tapers along a transitional portion to a flat end portion. The helically wound strands form a multistrand hollow cable which is partially flattened by pressure rollers as the cable travels along the transitional portion. The partially flattened cable is impacted with repeated hammer blows as the hollow cable travels along the flat end portion. The hammer blows flatten both the internal and the external surfaces of the strands. The cable is fully flattened and compacted by two sets of pressure rollers which engage the flat sides and the edges of the cable after it has traveled away from the flat end portion of the mandrel. The flattened internal surfaces slide easily over one another when the cable is flexed or bent so that there is very little possibility that the cable will be damaged by the necessary flexing and bending required to wind the cable into magnet coils.

  20. Columbia, OV-102, forward middeck locker experiments and meal tray assemblies

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Overall view of forward middeck locker shows Continuous Flow Electrophoresis System (CFES) experiment control and monitoring module and sample storage module (on port side) and Monodisperse Latex Reactor (MLR) (on starboard side). Water Dispenser Kit water gun (above CFES module) and meal tray assemblies covered with snack food packages and beverage containers appear around the two experiments. Thanks to a variety of juices and other food items, this array in the middeck probably represents the most colorful area onboard the Earth-orbiting Columbia, Orbiter Vehicle (OV) 102. Most of the meal items have been carefully fastened to meal tray assemblies (foodtrays) and locker doors (or both). What has not been attached by conventional methods has been safely 'tucked' under something heavy (note jacket shoved into space occupied MLR). MLR is making its second flight and is designed to test the flexibility of making large-size, monodisperse (same size), polystyrene latex micro-spheres using

  1. 49 CFR 172.331 - Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. 172.331 Section 172.331 Transportation Other Regulations... packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. (a) Each person...

  2. 49 CFR 172.331 - Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. 172.331 Section 172.331 Transportation Other Regulations... packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. (a) Each person...

  3. 49 CFR 172.331 - Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. 172.331 Section 172.331 Transportation Other Regulations... packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. (a) Each person...

  4. 49 CFR 172.331 - Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. 172.331 Section 172.331 Transportation Other Regulations... packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. (a) Each person...

  5. 49 CFR 172.331 - Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. 172.331 Section 172.331 Transportation Other Regulations... packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. (a) Each person...

  6. Space Flight Cable Model Development

    NASA Technical Reports Server (NTRS)

    Spak, Kaitlin

    2013-01-01

    This work concentrates the modeling efforts presented in last year's VSGC conference paper, "Model Development for Cable-Harnessed Beams." The focus is narrowed to modeling of space-flight cables only, as a reliable damped cable model is not yet readily available and is necessary to continue modeling cable-harnessed space structures. New experimental data is presented, eliminating the low-frequency noise that plagued the first year's efforts. The distributed transfer function method is applied to a single section of space flight cable for Euler-Bernoulli and shear beams. The work presented here will be developed into a damped cable model that can be incorporated into an interconnected beam-cable system. The overall goal of this work is to accurately predict natural frequencies and modal damping ratios for cabled space structures.

  7. 15. CLOSEUP VIEW OF SOUTHEAST CABLE BOLT, SUSPENSION CABLE, AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. CLOSE-UP VIEW OF SOUTHEAST CABLE BOLT, SUSPENSION CABLE, AND CONCRETE ANCHORING BLOCK, LOOKING SOUTHEAST - San Rafael Bridge, Spanning San Rafael River near Buckhorn Wash, Castle Dale, Emery County, UT

  8. 78 FR 34335 - Foreign-Trade Zone (FTZ) 141-Monroe County, New York; Notification of Proposed Production...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-07

    ... steel, fire and water resistant storage chests, gun safes, security safes, portable security safes, cash..., touchpads, plastic gun racks, keypad assemblies, panel lock assemblies, door backs, plastic trays, drawers..., wood gun shelf racks, cable assemblies, communication cables, gasket kits, door springs, metal handles...

  9. Non-Intrusive Cable Tester

    NASA Technical Reports Server (NTRS)

    Medelius, Pedro J. (Inventor); Simpson, Howard J. (Inventor)

    1999-01-01

    A cable tester is described for low frequency testing of a cable for faults. The tester allows for testing a cable beyond a point where a signal conditioner is installed, minimizing the number of connections which have to be disconnected. A magnetic pickup coil is described for detecting a test signal injected into the cable. A narrow bandpass filter is described for increasing detection of the test signal. The bandpass filter reduces noise so that a high gain amplifier provided for detecting a test signal is not completely saturate by noise. To further increase the accuracy of the cable tester, processing gain is achieved by comparing the signal from the amplifier with at least one reference signal emulating the low frequency input signal injected into the cable. Different processing techniques are described evaluating a detected signal.

  10. Cable coupling lightning transient qualification

    NASA Technical Reports Server (NTRS)

    Cook, M.

    1989-01-01

    Simulated lightning strike testing of instrumentation cabling on the redesigned solid rocket motor was performed. Testing consisted of subjecting the lightning evaluation test article to simulated lightning strikes and evaluating the effects of instrumentation cable transients on cables within the system tunnel. The maximum short-circuit current induced onto a United Space Boosters, Inc., operational flight cable within the systems tunnel was 92 A, and the maximum induced open-circuit voltage was 316 V. These levels were extrapolated to the worst-case (200 kA) condition of NASA specification NSTS 07636 and were also scaled to full-scale redesigned solid rocket motor dimensions. Testing showed that voltage coupling to cables within the systems tunnel can be reduced 40 to 90 dB and that current coupling to cables within the systems tunnel can be reduced 30 to 70 dB with the use of braided metallic sock shields around cables that are external to the systems tunnel. Testing also showed that current and voltage levels induced onto cables within the systems tunnel are partially dependant on the cables' relative locations within the systems tunnel. Results of current injections to the systems tunnel indicate that the dominant coupling mode on cables within the systems tunnel is not from instrumentation cables but from coupling through the systems tunnel cover seam apertures. It is recommended that methods of improving the electrical bonding between individual sections of the systems tunnel covers be evaluated. Further testing to better characterize redesigned solid rocket motor cable coupling effects as an aid in developing methods to reduce coupling levels, particularly with respect to cable placement within the systems tunnel, is also recommended.

  11. Stable group delay cable

    NASA Technical Reports Server (NTRS)

    Clements, P. A.

    1975-01-01

    It was found that group delay is function of pressure in air dielectric coaxial cable. For example, 600-ft air dielectric cable will change phase 10 deg at 150 MHz when air pressure in cable changes from zero to 20 psi.

  12. Study on The Effectiveness of Egg Tray and Coir Fibre as A Sound Absorber

    NASA Astrophysics Data System (ADS)

    Kaamin, Masiri; Farah Atiqah Ahmad, Nor; Ngadiman, Norhayati; Kadir, Aslila Abdul; Razali, Siti Nooraiin Mohd; Mokhtar, Mardiha; Sahat, Suhaila

    2018-03-01

    Sound or noise pollution has become one major issues to the community especially those who lived in the urban areas. It does affect the activity of human life. This excessive noise is mainly caused by machines, traffic, motor vehicles and also any unwanted sounds that coming from outside and even from the inside of the building. Such as a loud music. Therefore, the installation of sound absorption panel is one way to reduce the noise pollution inside a building. The selected material must be a porous and hollow in order to absorb high frequency sound. This study was conducted to evaluate the potential of egg tray and coir fibre as a sound absorption panel. The coir fibre has a good coefficient value which make it suitable as a sound absorption material and can replace the traditional material; syntactic and wooden material. The combination of pyramid shape of egg tray can provide a large surface for uniform sound reflection. This study was conducted by using a panel with size 1 m x 1 m with a thickness of 6 mm. This panel consist of egg tray layer, coir fibre layer and a fabric as a wrapping for the aesthetic value. Room reverberation test has been carried to find the loss of reverberation time (RT). Result shows that, a reverberation time reading is on low frequency, which is 125 Hz to 1600 Hz. Within these frequencies, this panel can shorten the reverberation time of 5.63s to 3.60s. Hence, from this study, it can be concluded that the selected materials have the potential as a good sound absorption panel. The comparison is made with the previous research that used egg tray and kapok as a sound absorption panel.

  13. [Computer aided design and 3-dimensional printing for the production of custom trays of maxillary edentulous jaws based on 3-dimensional scan of primary impression].

    PubMed

    Chen, H; Zhao, T; Wang, Y; Sun, Y C

    2016-10-18

    To establish a digital method for production of custom trays for edentulous jaws using fused deposition modeling (FDM) based on three-dimensional (3D) scans of primary jaw impressions, and to quantitatively evaluate the accuracy. A red modeling compound was used to make a primary impression of a standard maxillary edentulous plaster model. The plaster model data and the primary impression tissue surface data were obtained using a 3D scanner. In the Gemomagic 2012 software, several commands were used, such as interactive drawing curves, partial filling holes, local offset, bodily offset, bodily shell, to imitate clinical procedures of drawing tray boundary, filling undercut, buffer, and generating the tray body. A standard shape of tray handle was designed and attached to the tray body and the data saved as stereolithography (STL) format. The data were imported into a computer system connected to a 3D FDM printing device, and the custom tray for the edentulous jaw model was printed layer upon layer at 0.2 mm/layer, using polylactic acid (PLA) filament, the tissue surface of the tray was then scanned with a 3D scanner. The registration functions of Geomagic 2012 was used to register the 3-dimentional surface data, and the point-cloud deviation analysis function of the Imageware 13.0 system was used to analyze the error. The CAD data of the custom tray was registered to the scan data, and the error between them was analyzed. The scanned plaster model surface was registered to the scanned impression surface and the scanned tray data to the CAD data, then the distance between the surface of plaster model and the scanned tissue surface of the custom tray was measured in Imageware 13.0. The deviation between the computer aided design data and the scanned data of the custom tray was (0.17±0.20) mm, with (0.19±0.18) mm in the primary stress-bearing area, (0.17±0.22) mm in the secondary stress-bearing area, (0.30±0.29) mm in the border seal area, (0.08±0.06) mm in the

  14. Cable Tester

    NASA Technical Reports Server (NTRS)

    1989-01-01

    NASA Tech Brief's provided Sonics Associates, Inc. with a method of saving many hours of testing time and money. James B. Cawthon, Sonics Vice-President, read about a device developed at Ames Research Center. Sonics adapted the device and produced an effective tester that uses a clocked shift register to apply a voltage to a cable under test. This is the active part of the Ames development, and the passive is a small box containing light emitting diodes (LEDs). When connected to the other end of the tested cable, the LEDs light in the same sequence as the generator. This procedure allows the technician to immediately identify a miswired cable.

  15. Cable suspended windmill

    NASA Technical Reports Server (NTRS)

    Farmer, Moses G. (Inventor)

    1990-01-01

    A windmill is disclosed which includes an airframe having an upwind end and a downwind end. The first rotor is rotatably connected to the airframe, and a generator is supported by the airframe and driven by the rotor. The airframe is supported vertically in an elevated disposition by poles which extend vertically upwardly from the ground and support cables which extend between the vertical poles. Suspension cables suspend the airframe from the support cable.

  16. Normative data for distal line bisection and baking tray task.

    PubMed

    Facchin, Alessio; Beschin, Nicoletta; Pisano, Alessia; Reverberi, Cristina

    2016-09-01

    Line bisection is one of the tests used to diagnose unilateral spatial neglect (USN). Despite its wide application, no procedure or norms were available for the distal variant when the task was performed at distance with a laser pointer. Furthermore, the baking tray task was an ecological test aimed at diagnosing USN in a more natural context. The aim of this study was to collect normative values for these two tests in an Italian population. We recruited a sample of 191 healthy subjects with ages ranging from 20 to 89 years. They performed line bisection with a laser pointer on three different line lengths (1, 1.5, and 2 m) at a distance of 3 m. After this task, the subjects performed the baking tray task and a second repetition of line bisection to test the reliability of measurement. Multiple regression analysis revealed no significant effects of demographic variables on the performance of both tests. Normative cut-off values for the two tests were developed using non-parametric tolerance intervals. The results formed the basis for clinical use of these two tools for assessing lateralized performance of patients with brain injury and for diagnosing USN.

  17. Actin cable dynamics in budding yeast

    PubMed Central

    Yang, Hyeong-Cheol; Pon, Liza A.

    2002-01-01

    Actin cables, bundles of actin filaments that align along the long axis of budding yeast, are crucial for establishment of cell polarity. We fused green fluorescent protein (GFP) to actin binding protein 140 (Abp140p) and visualized actin cable dynamics in living yeast. We detected two populations of actin cables: (i) bud-associated cables, which extend from the bud along the mother-bud axis, and (ii) randomly oriented cables, which are relatively short. Time-lapse imaging of Abp140p–GFP revealed an apparent increase in the length of bud-associated actin cables. Analysis of movement of Abp140p–GFP fiduciary marks on bud-associated cables and fluorescence loss in photobleaching experiments revealed that this apparent elongation occurs by assembly of new material at the end of the cable within the bud and movement of the opposite end of the cable toward the tip of the mother cell distal to the bud. The rate of extension of the tip of an elongating actin cable is 0.29 ± 0.08 μm/s. Latrunculin A (Lat-A) treatment completely blocked this process. We also observed movement of randomly oriented cables around the cortex of cells at a rate of 0.59 ± 0.14 μm/s. Mild treatment with Lat-A did not affect the velocity of movement of randomly oriented cables. However, Lat-A treatment did increase the number of randomly oriented, motile cables per cell. Our observations suggest that establishment of bud-associated actin cables during the cell cycle is accomplished not by realignment of existing cables but by assembly of new cables within the bud or bud neck, followed by elongation. PMID:11805329

  18. Cable Television; A Bibliographic Review.

    ERIC Educational Resources Information Center

    Schoenung, James

    This bibliographic review of publications in the field of cable television begins with an introduction to cable television and an outline of the history and development of cable television. Particular attention is given to the regulatory activities of the Federal Communications Commission and the unfulfilled potential of cable television. The…

  19. Investigation of cables for ionization chambers.

    PubMed

    Spokas, J J; Meeker, R D

    1980-01-01

    Seven coaxial cables which are in use for carrying currents generated in ionization chambers have been critically studied with reference to their suitability to this application. Included in this study are four low-noise triaxial cables and three low-noise two-conductor cables. For each cable the following characteristics were considered: inherent noise currents, currents produced by cable movements, polarization currents, the degree of electrostatic shielding of the central signal-carrying conductor, and radiation-induced cable currents. The study indicated that of the seven cables, two low-noise triaxial cables, both employing solid Teflon dielectric surrounding the central conductor, appear to offer the best overall performance for use with ionization chambers.

  20. 52. View of sitdown cable car, cable way, and stream ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    52. View of sit-down cable car, cable way, and stream gaging station, looking southeast. Photo by Robin Lee Tedder, Puget Power, 1989. - Puget Sound Power & Light Company, White River Hydroelectric Project, 600 North River Avenue, Dieringer, Pierce County, WA

  1. 51. View of sitdown cable car and cable way for ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    51. View of sit-down cable car and cable way for stream gaging, looking west. Photo by Robin Lee Tedder, Puget Power, 1989. - Puget Sound Power & Light Company, White River Hydroelectric Project, 600 North River Avenue, Dieringer, Pierce County, WA

  2. 30 CFR 7.407 - Test for flame resistance of electric cables and cable splices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Test for flame resistance of electric cables... Electric Cables, Signaling Cables, and Cable Splice Kits § 7.407 Test for flame resistance of electric... a minimum of 24 hours at a temperature of 70 ±10 °F (21.1 ±5.5 °C) and a relative humidity of 55 ±10...

  3. 30 CFR 7.407 - Test for flame resistance of electric cables and cable splices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Test for flame resistance of electric cables... Electric Cables, Signaling Cables, and Cable Splice Kits § 7.407 Test for flame resistance of electric... a minimum of 24 hours at a temperature of 70 ±10 °F (21.1 ±5.5 °C) and a relative humidity of 55 ±10...

  4. 30 CFR 7.407 - Test for flame resistance of electric cables and cable splices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Test for flame resistance of electric cables... Electric Cables, Signaling Cables, and Cable Splice Kits § 7.407 Test for flame resistance of electric... a minimum of 24 hours at a temperature of 70 ±10 °F (21.1 ±5.5 °C) and a relative humidity of 55 ±10...

  5. Materials on the International Space Station Experiment (MISSE): Optical Analysis of Molecular Contamination on PEC1 Tray 2

    DTIC Science & Technology

    2007-02-20

    ellipsome- try and reflectometry were employed to show that the silicon wafers gained about a 420-A-thick layer of a silica-like con- taminant with BRDF...under Contract No. FA8802-04-C-0001. 111°. Contents I. Introduction .1 2. Ellipsometry and Reflectometry ... NASA ) I ;d~ ~ ---- ! Y Figure 2. MISSE I PECI Tray 2 facing away from Soyuz. (Courtesy NASA ) Among the samples mounted in PEC I Tray 2 were several

  6. Molds for cable dielectrics

    DOEpatents

    Roose, L.D.

    1996-12-10

    Molds for use in making end moldings for high-voltage cables are described wherein the dielectric insulator of a cable is heated and molded to conform to a desired shape. As a consequence, high quality substantially bubble-free cable connectors suitable for mating to premanufactured fittings are made. 5 figs.

  7. Cable Television: Franchising Considerations.

    ERIC Educational Resources Information Center

    Baer, Walter S.; And Others

    This volume is a comprehensive reference guide to cable television technology and issues of planning, franchising, and regulating a cable system. It is intended for local government officials and citizens concerned with the development of cable television systems in their communities, as well as for college and university classes in…

  8. Cable Library Survey Results.

    ERIC Educational Resources Information Center

    Public Service Satellite Consortium, Washington, DC.

    This report summarizes a survey of 198 libraries which had been identified as potential cable libraries which assessed: (1) to what extent a national satellite cable library network might already be in technical existence, (2) how many libraries are connected to cooperative cable companies with satellite hardware and excess receiver capacity, and…

  9. Colleges and Cable Franchising.

    ERIC Educational Resources Information Center

    Glenn, Neal D.

    After noting issues of audience appeal and financial and philosophical support for educational broadcasting, this paper urges community colleges to play an active role in the process of cable franchising. The paper first describes a cable franchise as a contract between a government unit and the cable television (CATV) company which specifies what…

  10. 14 CFR 25.689 - Cable systems.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.689 Cable systems. (a) Each cable, cable fitting, turnbuckle, splice, and pulley must be approved. In addition— (1) No cable... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Cable systems. 25.689 Section 25.689...

  11. Disposable telemetry cable deployment system

    DOEpatents

    Holcomb, David Joseph

    2000-01-01

    A disposable telemetry cable deployment system for facilitating information retrieval while drilling a well includes a cable spool adapted for insertion into a drill string and an unarmored fiber optic cable spooled onto the spool cable and having a downhole end and a stinger end. Connected to the cable spool is a rigid stinger which extends through a kelly of the drilling apparatus. A data transmission device for transmitting data to a data acquisition system is disposed either within or on the upper end of the rigid stinger.

  12. Cables and fire hazards

    NASA Technical Reports Server (NTRS)

    Zanelli, C.; Philbrick, S.; Beretta, G.

    1986-01-01

    Besides describing the experiments conducted to develop a nonflammable cable, this article discusses several considerations regarding other hazards which might result from cable fires, particularly the toxicity and opacity of the fumes emitted by the burning cable. In addition, this article examines the effects of using the Oxygen Index as a gauge of quality control during manufacture.

  13. 47 CFR 32.2422 - Underground cable.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... cable. This subsidiary record category shall include the original cost of optical fiber cable and other..., Buried Cable. (d) The cost of cables leading from the main distributing frame or equivalent to central...

  14. 47 CFR 32.2422 - Underground cable.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... cable. This subsidiary record category shall include the original cost of optical fiber cable and other..., Buried Cable. (d) The cost of cables leading from the main distributing frame or equivalent to central...

  15. 47 CFR 32.2422 - Underground cable.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... cable. This subsidiary record category shall include the original cost of optical fiber cable and other..., Buried Cable. (d) The cost of cables leading from the main distributing frame or equivalent to central...

  16. 47 CFR 32.2422 - Underground cable.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... cable. This subsidiary record category shall include the original cost of optical fiber cable and other..., Buried Cable. (d) The cost of cables leading from the main distributing frame or equivalent to central...

  17. 47 CFR 32.2422 - Underground cable.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... cable. This subsidiary record category shall include the original cost of optical fiber cable and other..., Buried Cable. (d) The cost of cables leading from the main distributing frame or equivalent to central...

  18. Cable-Dispensing Cart

    NASA Technical Reports Server (NTRS)

    Bredberg, Alan S.

    2003-01-01

    A versatile cable-dispensing cart can support as many as a few dozen reels of cable, wire, and/or rope. The cart can be adjusted to accommodate reels of various diameters and widths, and can be expanded, contracted, or otherwise reconfigured by use of easily installable and removable parts that can be carried onboard. Among these parts are dispensing rods and a cable guide that enables dispensing of cables without affecting the direction of pull. Individual reels can be mounted on or removed from the cart without affecting the other reels: this feature facilitates the replacement or reuse of partially depleted reels, thereby helping to reduce waste. Multiple cables, wires, or ropes can be dispensed simultaneously. For maneuverability, the cart is mounted on three wheels. Once it has been positioned, the cart is supported by rubber mounts for stability and for prevention of sliding or rolling during dispensing operations. The stability and safety of the cart are enhanced by a low-center-of-gravity design. The cart can readily be disassembled into smaller units for storage or shipping, then reassembled in the desired configuration at a job site.

  19. Test plan and report for Space Shuttle launch environment testing of Bergen cable technology safety cable

    NASA Technical Reports Server (NTRS)

    Ralph, John

    1992-01-01

    Bergen Cable Technology (BCT) has introduced a new product they refer to as 'safety cable'. This product is intended as a replacement for lockwire when installed per Aerospace Standard (AS) 4536 (included in Appendix D of this document). Installation of safety cable is reportedly faster and more uniform than lockwire. NASA/GSFC proposes to use this safety cable in Shuttle Small Payloads Project (SSPP) applications on upcoming Shuttle missions. To assure that BCT safety cable will provide positive locking of fasteners equivalent to lockwire, the SSPP will conduct vibration and pull tests of the safety cable.

  20. Shape accuracy optimization for cable-rib tension deployable antenna structure with tensioned cables

    NASA Astrophysics Data System (ADS)

    Liu, Ruiwei; Guo, Hongwei; Liu, Rongqiang; Wang, Hongxiang; Tang, Dewei; Song, Xiaoke

    2017-11-01

    Shape accuracy is of substantial importance in deployable structures as the demand for large-scale deployable structures in various fields, especially in aerospace engineering, increases. The main purpose of this paper is to present a shape accuracy optimization method to find the optimal pretensions for the desired shape of cable-rib tension deployable antenna structure with tensioned cables. First, an analysis model of the deployable structure is established by using finite element method. In this model, geometrical nonlinearity is considered for the cable element and beam element. Flexible deformations of the deployable structure under the action of cable network and tensioned cables are subsequently analyzed separately. Moreover, the influence of pretension of tensioned cables on natural frequencies is studied. Based on the results, a genetic algorithm is used to find a set of reasonable pretension and thus minimize structural deformation under the first natural frequency constraint. Finally, numerical simulations are presented to analyze the deployable structure under two kinds of constraints. Results show that the shape accuracy and natural frequencies of deployable structure can be effectively improved by pretension optimization.

  1. Integrated Structural and Cable Connector

    NASA Technical Reports Server (NTRS)

    Totah, R. S.

    1982-01-01

    Ball-and-socket coupling includes fiber-optic cable. Three steps couple two parts of fiber-optic cable: ball is inserted into socket; cone is released in, and cable moves toward plug. Sleeve is pulled to end of its travel and cable and plug are mated. Device is a quick-connect/disconnect coupling that has application in hazardous environments, such as space, undersea and nuclear installations.

  2. Applying Diagnostics to Enhance Cable System Reliability (Cable Diagnostic Focused Initiative, Phase II)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hartlein, Rick; Hampton, Nigel; Perkel, Josh

    2016-02-01

    The Cable Diagnostic Focused Initiative (CDFI) played a significant and powerful role in clarifying the concerns and understanding the benefits of performing diagnostic tests on underground power cable systems. This project focused on the medium and high voltage cable systems used in utility transmission and distribution (T&D) systems. While many of the analysis techniques and interpretations are applicable to diagnostics and cable systems outside of T&D, areas such as generating stations (nuclear, coal, wind, etc.) and other industrial environments were not the focus. Many large utilities in North America now deploy diagnostics or have changed their diagnostic testing approach asmore » a result of this project. Previous to the CDFI, different diagnostic technology providers individually promoted their approach as the “the best” or “the only” means of detecting cable system defects.« less

  3. Development of inspection robots for bridge cables.

    PubMed

    Yun, Hae-Bum; Kim, Se-Hoon; Wu, Liuliu; Lee, Jong-Jae

    2013-01-01

    This paper presents the bridge cable inspection robot developed in Korea. Two types of the cable inspection robots were developed for cable-suspension bridges and cable-stayed bridge. The design of the robot system and performance of the NDT techniques associated with the cable inspection robot are discussed. A review on recent advances in emerging robot-based inspection technologies for bridge cables and current bridge cable inspection methods is also presented.

  4. EVALUATION OF FLOORPAN TEARING AND CABLE SPLICES FOR CABLE BARRIER SYSTEMS

    DOT National Transportation Integrated Search

    2017-05-26

    This research effort consisted of two objectives related to components of a prototype cable barrier system. The first objective was to mitigate the potential for vehicle floorpan tearing by modifying the cable guardrail posts. A bogie vehicle was equ...

  5. Photonic-powered cable assembly

    DOEpatents

    Sanderson, Stephen N.; Appel, Titus James; Wrye, IV, Walter C.

    2013-01-22

    A photonic-cable assembly includes a power source cable connector ("PSCC") coupled to a power receive cable connector ("PRCC") via a fiber cable. The PSCC electrically connects to a first electronic device and houses a photonic power source and an optical data transmitter. The fiber cable includes an optical transmit data path coupled to the optical data transmitter, an optical power path coupled to the photonic power source, and an optical feedback path coupled to provide feedback control to the photonic power source. The PRCC electrically connects to a second electronic device and houses an optical data receiver coupled to the optical transmit data path, a feedback controller coupled to the optical feedback path to control the photonic power source, and a photonic power converter coupled to the optical power path to convert photonic energy received over the optical power path to electrical energy to power components of the PRCC.

  6. Photonic-powered cable assembly

    DOEpatents

    Sanderson, Stephen N; Appel, Titus James; Wrye, IV, Walter C

    2014-06-24

    A photonic-cable assembly includes a power source cable connector ("PSCC") coupled to a power receive cable connector ("PRCC") via a fiber cable. The PSCC electrically connects to a first electronic device and houses a photonic power source and an optical data transmitter. The fiber cable includes an optical transmit data path coupled to the optical data transmitter, an optical power path coupled to the photonic power source, and an optical feedback path coupled to provide feedback control to the photonic power source. The PRCC electrically connects to a second electronic device and houses an optical data receiver coupled to the optical transmit data path, a feedback controller coupled to the optical feedback path to control the photonic power source, and a photonic power converter coupled to the optical power path to convert photonic energy received over the optical power path to electrical energy to power components of the PRCC.

  7. Environmental Impact of a Submarine Cable: Case Study of the Acoustic Thermometry of Ocean Climate (ATOC)/ Pioneer Seamount Cable

    NASA Astrophysics Data System (ADS)

    Kogan, I.; Paull, C. K.; Kuhnz, L.; von Thun, S.; Burton, E.; Greene, H. G.; Barry, J. P.

    2003-12-01

    To better understand the potential impacts of the presence of cables on the seabed, a topic of interest for which little data is published or publicly available, a study of the environmental impacts of the ATOC/Pioneer Seamount cable was conducted. The 95 km long, submarine, coaxial cable extends between Pioneer Seamount and the Pillar Point Air Force Station in Half Moon Bay, California. Approximately two thirds of the cable lies within the Monterey Bay National Marine Sanctuary. The cable is permitted to NOAA- Oceanic and Atmospheric Research for transmitting data from a hydrophone array on Pioneer Seamount to shore. The cable was installed unburied on the seafloor in 1995. The cable path crosses the continental shelf, descends to a maximum depth of 1,933 m, and climbs back upslope to 998 m depth near the crest of Pioneer Seamount. A total of 42 hours of video and 152 push cores were collected in 10 stations along cable and control transects using the ROVs Ventana and Tiburon equipped with cable-tracking tools. The condition of the cable, its effect on the seafloor, and distribution of benthic megafauna and infauna were determined. Video data indicated the nature of interaction between the cable and the seafloor. Rocky nearshore areas, where wave energies are greatest, showed the clearest evidence of impact. Here, evidence of abrasion included frayed and unraveling portions of the cable's armor and vertical grooves in the rock apparently cut by the cable. The greatest incision and armor damage occurred on ledges between spans in irregular rock outcrop areas. Unlike the nearshore rocky region, neither the rocks nor the cable appeared damaged along outcrops on Pioneer Seamount. Multiple loops of slack cable added during a 1997 cable repair operation were found lying flat on the seafloor. Several sharp kinks in the cable were seen at 240 m water depths in an area subjected to intense trawling activity. Most of the cable has become buried with time in sediment

  8. 49 CFR 172.330 - Tank cars and multi-unit tank car tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Tank cars and multi-unit tank car tanks. 172.330..., TRAINING REQUIREMENTS, AND SECURITY PLANS Marking § 172.330 Tank cars and multi-unit tank car tanks. (a... material— (1) In a tank car unless the following conditions are met: (i) The tank car must be marked on...

  9. 49 CFR 172.330 - Tank cars and multi-unit tank car tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Tank cars and multi-unit tank car tanks. 172.330..., TRAINING REQUIREMENTS, AND SECURITY PLANS Marking § 172.330 Tank cars and multi-unit tank car tanks. (a... material— (1) In a tank car unless the following conditions are met: (i) The tank car must be marked on...

  10. 49 CFR 172.330 - Tank cars and multi-unit tank car tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Tank cars and multi-unit tank car tanks. 172.330..., TRAINING REQUIREMENTS, AND SECURITY PLANS Marking § 172.330 Tank cars and multi-unit tank car tanks. (a... material— (1) In a tank car unless the following conditions are met: (i) The tank car must be marked on...

  11. Development of Inspection Robots for Bridge Cables

    PubMed Central

    Kim, Se-Hoon; Lee, Jong-Jae

    2013-01-01

    This paper presents the bridge cable inspection robot developed in Korea. Two types of the cable inspection robots were developed for cable-suspension bridges and cable-stayed bridge. The design of the robot system and performance of the NDT techniques associated with the cable inspection robot are discussed. A review on recent advances in emerging robot-based inspection technologies for bridge cables and current bridge cable inspection methods is also presented. PMID:24459453

  12. Internal coaxial cable seal system

    DOEpatents

    Hall, David R.; Sneddon, Cameron; Dahlgren, Scott Steven; Briscoe, Michael A.

    2006-07-25

    The invention is a seal system for a coaxial cable and is placed within the coaxial cable and its constituent components. A series of seal stacks including load ring components and elastomeric rings are placed on load bearing members within the coaxial cable sealing the annular space between the coaxial cable and an electrical contact passing there through. The coaxial cable is disposed within drilling components to transmit electrical signals between drilling components within a drill string. The seal system can be used in a variety of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars.

  13. Flat conductor cable commercialization project

    NASA Technical Reports Server (NTRS)

    Hogarth, P.; Wadsworth, E.

    1977-01-01

    An undercarpet flat conductor cable and a baseboard flat conductor cable system were studied for commercialization. The undercarpet system is designed for use in office and commercial buildings. It employs a flat power cable, protected by a grounded metal shield, that terminates in receptacles mounted on the floor. It is designed to interface with a flat conductor cable telephone system. The baseboard system consists of a flat power cable mounted in a plastic raceway; both the raceway and the receptacles are mounted on the surface of the baseboard. It is designed primarily for use in residential buildings, particularly for renovation and concrete and masonry construction.

  14. Cabling design for phased arrays

    NASA Technical Reports Server (NTRS)

    Kruger, I. D.; Turkiewicz, L.

    1972-01-01

    The ribbon-cabling system used for the AEGIS phased array which provides minimum cable bulk, complete EMI shielding, rugged mechanical design, repeatable electrical characteristics, and ease of assembly and maintenance is described. The ribbon cables are 0.040-inch thick, and in widths up to 2 1/2 inches. Their terminations are molded connectors that can be grouped in a three-tier arrangement, with cable branching accomplished by a matrix-welding technique.

  15. Self-healing cable apparatus and methods

    NASA Technical Reports Server (NTRS)

    Huston, Dryver (Inventor); Esser, Brian (Inventor)

    2007-01-01

    Self-healing cable apparatus and methods are disclosed. The cable has a central core surrounded by an adaptive cover that can extend over the entire length of the cable or just one or more portions of the cable. The adaptive cover includes a protective layer having an initial damage resistance, and a reactive layer. When the cable is subjected to a localized damaging force, the reactive layer responds by creating a corresponding localized self-healed region. The self-healed region provides the cable with enhanced damage resistance as compared to the cable's initial damage resistance. Embodiments of the invention utilize conventional epoxies or foaming materials in the reactive layer that are released to form the self-healed region when the damaging force reaches the reactive layer.

  16. Correction coil cable

    DOEpatents

    Wang, S.T.

    1994-11-01

    A wire cable assembly adapted for the winding of electrical coils is taught. A primary intended use is for use in particle tube assemblies for the Superconducting Super Collider. The correction coil cables have wires collected in wire array with a center rib sandwiched therebetween to form a core assembly. The core assembly is surrounded by an assembly housing having an inner spiral wrap and a counter wound outer spiral wrap. An alternate embodiment of the invention is rolled into a keystoned shape to improve radial alignment of the correction coil cable on a particle tube in a particle tube assembly. 7 figs.

  17. Cables and connectors: A compilation

    NASA Technical Reports Server (NTRS)

    1974-01-01

    A technological compilation on devices and techniques for various types of electrical cables and connections is presented. Data are reported under three sections: flat conductor cable technology, newly developed electrical connectors, and miscellaneous articles and information on cables and connector techniques.

  18. Cable deformation simulation and a hierarchical framework for Nb3Sn Rutherford cables

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arbelaez, D.; Prestemon, S. O.; Ferracin, P.

    2009-09-13

    Knowledge of the three-dimensional strain state induced in the superconducting filaments due to loads on Rutherford cables is essential to analyze the performance of Nb{sub 3}Sn magnets. Due to the large range of length scales involved, we develop a hierarchical computational scheme that includes models at both the cable and strand levels. At the Rutherford cable level, where the strands are treated as a homogeneous medium, a three-dimensional computational model is developed to determine the deformed shape of the cable that can subsequently be used to determine the strain state under specified loading conditions, which may be of thermal, magnetic,more » and mechanical origins. The results can then be transferred to the model at the strand/macro-filament level for rod restack process (RRP) strands, where the geometric details of the strand are included. This hierarchical scheme can be used to estimate the three-dimensional strain state in the conductor as well as to determine the effective properties of the strands and cables from the properties of individual components. Examples of the modeling results obtained for the orthotropic mechanical properties of the Rutherford cables are presented.« less

  19. New Life For The Cable Cars

    NASA Technical Reports Server (NTRS)

    1979-01-01

    NASA-Arnes' major recommendations involved ways of extending cable life in the interests of safety and economy. Other recommendations included redesign of the cablegripping device, substitution of modern braking mechanisms, improvements in cable pulleys and other components, and new inspection and repair procedures. Ames followed up by designing and installing new equipment to lengthen cable life, which averages only about two months. These cables-four of them for four different car routes--are endless belts, like ski lift cables, running from the downtown car barn to the end of each line. When a cable is installed, the loop is closed by splicing the ends together in a 72-footlong splice. The splice is the weakest part of the cable and a source of problems. When the car operator applies his grip while over a splice, the resulting friction sometimes causes the splice to "unbraid" and fail; this means shutting down the line until the splice can be repaired. Even when unbraiding does not occur, gripping a splice shortens cable life by friction wear. Worn cables are a safety hazard and must be replaced, which is expensive at $1.60 a foot for 10,000 to 20,000 feet of cable.

  20. 49 CFR 174.63 - Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car tanks. 174.63 Section 174.63 Transportation Other....63 Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

  1. 49 CFR 174.63 - Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car tanks. 174.63 Section 174.63 Transportation Other....63 Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

  2. 49 CFR 174.63 - Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car tanks. 174.63 Section 174.63 Transportation Other....63 Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

  3. 49 CFR 174.63 - Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car tanks. 174.63 Section 174.63 Transportation Other....63 Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

  4. 49 CFR 174.63 - Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car tanks. 174.63 Section 174.63 Transportation Other....63 Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

  5. Process of modifying a cable end

    DOEpatents

    Roose, L.D.

    1995-08-01

    End moldings for high-voltage cables are described wherein the dielectric insulator of the cable is heated and molded to conform to a desired shape. As a consequence, high quality substantially bubble-free cable connectors suitable for mating to premanufactured fittings are made. Disclosed are a method for making the cable connectors either in the field or in a factory, molds suitable for use with the method, and the molded cable connectors, themselves. 5 figs.

  6. High-acceleration cable deployment

    NASA Technical Reports Server (NTRS)

    Barns, C. E.; Canning, T. N.; Gin, B.; King, R. W.; Murphy, J. P.

    1980-01-01

    Prototype high-acceleration umbilical-cable deployment allows electrical communication between above-ground instrumentation and ballistic projectile below surface. Cable deployment is made up of forebody and afterbody. Foreboy can be separated from afterbody by rocket, or they can be fired as unit at target that stops afterbody on impact (forebody would continue, deploying cable). Similar design could be used in study of sea ice and in other surface-penetration studies.

  7. Acoustic emission monitoring of CFRP cables for cable-stayed bridges

    NASA Astrophysics Data System (ADS)

    Rizzo, Piervincenzo; Lanza di Scalea, Francesco

    2001-08-01

    The advantages of fiber-reinforced polymer (FRP) composite include excellent corrosion resistance, high specific strength and stiffness, as well as outstanding fatigue behavior. The University of California San Diego's I- 5/Gilman Advanced Technology Bridge Project will help demonstrating the use of such materials in civil infrastructures. This paper presents an acoustic emission (AE) study performed during laboratory proof tests of carbon fiber-reinforced polymer stay-cables of possible use in the I-5/Gilman bridge. Three types of cables, both braided and single strand, were tested to failure at lengths ranging from 5500 mm to 5870 mm. AE allowed to monitor damage initiation and progression in the test pieces more accurately than the conventional load versus displacement curve. All of the cables exhibited acoustic activities revealing some degree of damage well before reaching final collapse, which is expected in FRP's. It was also shown that such cables are excellent acoustic waveguides exhibiting very low acoustic attenuation, which makes them an ideal application for an AE-based health monitoring approach.

  8. Cable in Connecticut; a Citizen's Handbook.

    ERIC Educational Resources Information Center

    Cleland, Margaret

    This handbook for Connecticut cable television consumers addresses a variety of topics, including: (1) a definition of cable television services; (2) the public stake in cable television; (3) program variety; (4) pay cable service; (5) public satellites; (6) government regulation; (7) proposed regulation; (8) role of the Connecticut Public…

  9. 14 CFR 27.1365 - Electric cables.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Electric cables. 27.1365 Section 27.1365... STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Electrical Systems and Equipment § 27.1365 Electric cables. (a) Each electric connecting cable must be of adequate capacity. (b) Each cable that would overheat...

  10. 14 CFR 27.1365 - Electric cables.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Electric cables. 27.1365 Section 27.1365... STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Electrical Systems and Equipment § 27.1365 Electric cables. (a) Each electric connecting cable must be of adequate capacity. (b) Each cable that would overheat...

  11. 14 CFR 27.1365 - Electric cables.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Electric cables. 27.1365 Section 27.1365... STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Electrical Systems and Equipment § 27.1365 Electric cables. (a) Each electric connecting cable must be of adequate capacity. (b) Each cable that would overheat...

  12. 14 CFR 27.1365 - Electric cables.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Electric cables. 27.1365 Section 27.1365... STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Electrical Systems and Equipment § 27.1365 Electric cables. (a) Each electric connecting cable must be of adequate capacity. (b) Each cable that would overheat...

  13. 14 CFR 27.1365 - Electric cables.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Electric cables. 27.1365 Section 27.1365... STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Electrical Systems and Equipment § 27.1365 Electric cables. (a) Each electric connecting cable must be of adequate capacity. (b) Each cable that would overheat...

  14. Hybrid modeling for dynamic analysis of cable-pulley systems with time-varying length cable and its application

    NASA Astrophysics Data System (ADS)

    Wang, Jing; Qi, Zhaohui; Wang, Gang

    2017-10-01

    The dynamic analysis of cable-pulley systems is investigated in this paper, where the time-varying length characteristic of the cable as well as the coupling motion between the cable and the pulleys are considered. The dynamic model for cable-pulley systems are presented based on the principle of virtual power. Firstly, the cubic spline interpolation is adopted for modeling the flexible cable elements and the virtual 1powers of tensile strain, inertia and gravity forces on the cable are formulated. Then, the coupled motions between the cable and the movable or fixed pulley are described by the input and output contact points, based on the no-slip assumption and the spatial description. The virtual powers of inertia, gravity and applied forces on the contact segment of the cable, the movable and fixed pulleys are formulated. In particular, the internal node degrees of freedom of spline cable elements are reduced, which results in that only the independent description parameters of the nodes connected to the pulleys are included in the final governing dynamic equations. At last, two cable-pulley lifting mechanisms are considered as demonstrative application examples where the vibration of the lifting process is investigated. The comparison with ADAMS models is given to prove the validity of the proposed method.

  15. System for effecting underwater coupling of optical fiber cables characterized by a novel lateral arm cable capture mechanism

    NASA Astrophysics Data System (ADS)

    Hillenbrand, Christopher F.

    1995-03-01

    A submarine trails one fiber optic cable and an undersea vehicle is controlled by this first cable. A missile/torpedo trails a second cable that is to be coupled to the first cable. The second cable has a segment suspended vertically underwater between a buoyant pod and a sea anchor type buoy. The undersea vehicle, or autonomous undersea vehicle, (AUV) hunts for the pod by conventional homing components, and cable capturing arms on the vehicle direct the cable's movement relative to the vehicle into a pod mating position that achieves optical coupling of the two cables. In one embodiment two arms are pivotably mounted to the vehicle's sides so one arm captures the suspended cable segment directing it into a slot so a male socket in the underside of the pod mates with a female socket in the slot. Another embodiment accomplishes the same result with a device in which the arms are formed as the off-shoots of a forked cable pickup device in the nose of the AUV.

  16. Cable Television Interconnection.

    ERIC Educational Resources Information Center

    Cable Television Information Center, Washington, DC.

    State and local governments have not been involved in the complexities of cable television interconnection issues in the past despite opportunities. Without their intervention, the result may well be a lack of concern for local public services. However, the entertainment and communications industries will interconnect cable systems without the…

  17. System for effecting underwater coupling of optical fiber cables characterized by a novel V-probe cable capture mechanism

    NASA Astrophysics Data System (ADS)

    Hillenbrand, Christopher F.; Barron, Thomas D.; Nugent, David M.

    1995-03-01

    A submarine trails one fiber optic cable and an undersea vehicle is controlled by this first cable. A missile/torpedo trails a second cable that is to be coupled to the first cable. The second cable has a segment suspended vertically underwater between a buoyant pod and a sea anchor type buoy. The undersea vehicle, or Autonomous Undersea Vehicle, (AUV) hunts for the pod by conventional homing means. A forked cable pickup device in the nose of the AUV captures the suspended cable segment directing it into a slot so a male socket in the underside of the pod mates with a female socket in the slot.

  18. Cable Television, Market Power and Regulation.

    ERIC Educational Resources Information Center

    Thorpe, Kenneth E.

    The goals of this dissertation are to provide an empirical examination of the impact of competing technologies on cable television firms and to document existing pricing behavior in the cable and pay programming industry. The introduction provides a brief overview of the cable television industry, including the impact of cable on federal policy…

  19. Installation and Assembly, Electrical Ground Support Equipment (GSE), Specification for

    NASA Technical Reports Server (NTRS)

    Denson, Erik C.

    2014-01-01

    This specification covers the general workmanship requirements and procedures for the complete installation and assembly of electrical ground support equipment (EGSE) such as terminal distributors, junction boxes, conduit and fittings, cable trays and accessories, interconnecting cables (including routing requirements), motor-control equipment, and necessary hardware as specified by the applicable contract and drawings.

  20. 29 CFR 1910.306 - Specific purpose equipment and installations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... means required by paragraph (e)(1) of this section. (f) X-Ray equipment. This paragraph applies to X-ray... disconnecting means shall be operable from a location readily accessible from the X-ray control. For equipment... suitable nonmetallic raceways or cable trays; or (C) Wire or cable in suitable metal raceways or metal...

  1. 29 CFR 1910.306 - Specific purpose equipment and installations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... means required by paragraph (e)(1) of this section. (f) X-Ray equipment. This paragraph applies to X-ray... disconnecting means shall be operable from a location readily accessible from the X-ray control. For equipment... suitable nonmetallic raceways or cable trays; or (C) Wire or cable in suitable metal raceways or metal...

  2. Cable Television Information.

    ERIC Educational Resources Information Center

    New York State Education Dept. , Albany. Bureau of Mass Communications.

    Included in this compendium are fifteen documents pertaining to cable television for New York State. Two of the documents deal with the relationships between school districts and the cable operators. The arrangements discussed are from the experiences of the Michigan State School System and the Pasadena, California School District. These reveal…

  3. Reliability and accuracy of real-time visualization techniques for measuring school cafeteria tray waste: validating the quarter-waste method.

    PubMed

    Hanks, Andrew S; Wansink, Brian; Just, David R

    2014-03-01

    Measuring food waste is essential to determine the impact of school interventions on what children eat. There are multiple methods used for measuring food waste, yet it is unclear which method is most appropriate in large-scale interventions with restricted resources. This study examines which of three visual tray waste measurement methods is most reliable, accurate, and cost-effective compared with the gold standard of individually weighing leftovers. School cafeteria researchers used the following three visual methods to capture tray waste in addition to actual food waste weights for 197 lunch trays: the quarter-waste method, the half-waste method, and the photograph method. Inter-rater and inter-method reliability were highest for on-site visual methods (0.90 for the quarter-waste method and 0.83 for the half-waste method) and lowest for the photograph method (0.48). This low reliability is partially due to the inability of photographs to determine whether packaged items (such as milk or yogurt) are empty or full. In sum, the quarter-waste method was the most appropriate for calculating accurate amounts of tray waste, and the photograph method might be appropriate if researchers only wish to detect significant differences in waste or consumption of selected, unpackaged food. Copyright © 2014 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  4. OTEC riser cable model and prototype testing

    NASA Astrophysics Data System (ADS)

    Kurt, J. P.; Schultz, J. A.; Roblee, L. H. S.

    1981-12-01

    Two different OTEC riser cables have been developed to span the distance between a floating OTEC power plant and the ocean floor. The major design concerns for a riser cable in the dynamic OTEC environment are fatigue, corrosion, and electrical/mechanical aging of the cable components. The basic properties of the cable materials were studied through tests on model cables and on samples of cable materials. Full-scale prototype cables were manufactured and were tested to measure their electrical and mechanical properties and performance. The full-scale testing was culminated by the electrical/mechanical fatigue test, which exposes full-scale cables to simultaneous tension, bending and electrical loads, all in a natural seawater environment.

  5. Instrumentation Cables Test Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muna, Alice Baca; LaFleur, Chris Bensdotter

    A fire at a nuclear power plant (NPP) has the potential to damage structures, systems, and components important to safety, if not promptly detected and suppressed. At Browns Ferry Nuclear Power Plant on March 22, 1975, a fire in the reactor building damaged electrical power and control systems. Damage to instrumentation cables impeded the function of both normal and standby reactor coolant systems, and degraded the operators’ plant monitoring capability. This event resulted in additional NRC involvement with utilities to ensure that NPPs are properly protected from fire as intended by the NRC principle design criteria (i.e., general design criteriamore » 3, Fire Protection). Current guidance and methods for both deterministic and performance based approaches typically make conservative (bounding) assumptions regarding the fire-induced failure modes of instrumentation cables and those failure modes effects on component and system response. Numerous fire testing programs have been conducted in the past to evaluate the failure modes and effects of electrical cables exposed to severe thermal conditions. However, that testing has primarily focused on control circuits with only a limited number of tests performed on instrumentation circuits. In 2001, the Nuclear Energy Institute (NEI) and the Electric Power Research Institute (EPRI) conducted a series of cable fire tests designed to address specific aspects of the cable failure and circuit fault issues of concern1. The NRC was invited to observe and participate in that program. The NRC sponsored Sandia National Laboratories to support this participation, whom among other things, added a 4-20 mA instrumentation circuit and instrumentation cabling to six of the tests. Although limited, one insight drawn from those instrumentation circuits tests was that the failure characteristics appeared to depend on the cable insulation material. The results showed that for thermoset insulated cables, the instrument reading tended

  6. Cable tester

    NASA Astrophysics Data System (ADS)

    Rammage, Robert L.

    1990-10-01

    A device for sequentially testing the plurality of connectors in a wiring harness is disclosed. The harness is attached to the tester by means of adapter cables and a rotary switch is used to sequentially, individually test the connectors by passing a current through the connector. If the connector is unbroken, a light will flash to show it is electrically sound. The adapters allow a large number of cable configurations to be tested using a single tester configuration.

  7. Thermal analysis of underground power cable system

    NASA Astrophysics Data System (ADS)

    Rerak, Monika; Ocłoń, Paweł

    2017-10-01

    The paper presents the application of Finite Element Method in thermal analysis of underground power cable system. The computations were performed for power cables buried in-line in the ground at a depth of 2 meters. The developed mathematical model allows determining the two-dimensional temperature distribution in the soil, thermal backfill and power cables. The simulations studied the effect of soil and cable backfill thermal conductivity on the maximum temperature of the cable conductor. Also, the effect of cable diameter on the temperature of cable core was studied. Numerical analyses were performed based on a program written in MATLAB.

  8. Charge-Dissipative Electrical Cables

    NASA Technical Reports Server (NTRS)

    Kolasinski, John R.; Wollack, Edward J.

    2004-01-01

    Electrical cables that dissipate spurious static electric charges, in addition to performing their main functions of conducting signals, have been developed. These cables are intended for use in trapped-ion or ionizing-radiation environments, in which electric charges tend to accumulate within, and on the surfaces of, dielectric layers of cables. If the charging rate exceeds the dissipation rate, charges can accumulate in excessive amounts, giving rise to high-current discharges that can damage electronic circuitry and/or systems connected to it. The basic idea of design and operation of charge-dissipative electrical cables is to drain spurious charges to ground by use of lossy (slightly electrically conductive) dielectric layers, possibly in conjunction with drain wires and/or drain shields (see figure). In typical cases, the drain wires and/or drain shields could be electrically grounded via the connector assemblies at the ends of the cables, in any of the conventional techniques for grounding signal conductors and signal shields. In some cases, signal shields could double as drain shields.

  9. GEOS-20 m cable boom mechanism

    NASA Technical Reports Server (NTRS)

    Schmidt, B. K.; Suttner, K.

    1977-01-01

    The GEOS cable boom mechanism allows the controlled deployment of a 20 m long cable in a centrifugal force field. In launch configuration the flat cable is reeled on a 240 mm diameter drum. The electrical connection between the rotating drum and the stationary housing is accomplished via a flexlead positioned inside the drum. Active motion control of this drum is achieved by a self locking worm gear, driven by a stepper motor. The deployment length of the cable is monitored by an optical length indicator, sensing black bars engraved on the cable surface.

  10. Development of an integrated, unattended assay system for LWR-MOX fuel pellet trays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stewart, J.E.; Hatcher, C.R.; Pollat, L.L.

    1994-08-01

    Four identical unattended plutonium assay systems have been developed for use at the new light-water-reactor mixed oxide (LWR-MOX) fuel fabrication facility at Hanau, Germany. The systems provide quantitative plutonium verification for all MOX pellet trays entering or leaving a large, intermediate store. Pellet-tray transport and storage systems are highly automated. Data from the ``I-Point`` (information point) assay systems will be shared by the Euratom and International Atomic Energy Agency (IAEA) Inspectorates. The I-Point system integrates, for the first time, passive neutron coincidence counting (NCC) with electro-mechanical sensing (EMS) in unattended mode. Also, provisions have been made for adding high-resolution gammamore » spectroscopy. The system accumulates data for every tray entering or leaving the store between inspector visits. During an inspection, data are analyzed and compared with operator declarations for the previous inspection period, nominally one month. Specification of the I-point system resulted from a collaboration between the IAEA, Euratom, Siemens, and Los Alamos. Hardware was developed by Siemens and Los Alamos through a bilateral agreement between the German Federal Ministry of Research and Technology (BMFT) and the US DOE. Siemens also provided the EMS subsystem, including software. Through the USSupport Program to the IAEA, Los Alamos developed the NCC software (NCC COLLECT) and also the software for merging and reviewing the EMS and NCC data (MERGE/REVIEW). This paper describes the overall I-Point system, but emphasizes the NCC subsystem, along with the NCC COLLECT and MERGE/REVIEW codes. We also summarize comprehensive testing results that define the quality of assay performance.« less

  11. A cable-driven parallel robots application: modelling and simulation of a dynamic cable model in Dymola

    NASA Astrophysics Data System (ADS)

    Othman, M. F.; Kurniawan, R.; Schramm, D.; Ariffin, A. K.

    2018-05-01

    Modeling a cable model in multibody dynamics simulation tool which dynamically varies in length, mass and stiffness is a challenging task. Simulation of cable-driven parallel robots (CDPR) for instance requires a cable model that can dynamically change in length for every desired pose of the platform. Thus, in this paper, a detailed procedure for modeling and simulation of a dynamic cable model in Dymola is proposed. The approach is also applicable for other types of Modelica simulation environments. The cable is modeled using standard mechanical elements like mass, spring, damper and joint. The parameters of the cable model are based on the factsheet of the manufacturer and experimental results. Its dynamic ability is tested by applying it on a complete planar CDPR model in which the parameters are based on a prototype named CABLAR, which is developed in Chair of Mechatronics, University of Duisburg-Essen. The prototype has been developed to demonstrate an application of CDPR as a goods storage and retrieval machine. The performance of the cable model during the simulation is analyzed and discussed.

  12. Bulk Electrical Cable Non-Destructive Examination Methods for Nuclear Power Plant Cable Aging Management Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glass, Samuel W.; Jones, Anthony M.; Fifield, Leonard S.

    This Pacific Northwest National Laboratory milestone report describes progress to date on the investigation of nondestructive test methods focusing particularly on bulk electrical test methods that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As nuclear power plants consider applying for second, or subsequent, license renewal to extend their operating period from 60 years to 80 years, it is important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs to assuremore » continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program, however, is directed toward the more demanding challenge of assuring the cable function under accident or DBE. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB, however, is a destructive test so the test programs must apply an array of other nondestructive examination (NDE) tests to assure or infer the overall set of cable’s system integrity. Assessment of cable integrity is further complicated in many cases by vendor’s use of dissimilar material for jacket and insulation. Frequently the jacket will degrade more rapidly than the underlying insulation. Although this can serve as an early alert to cable damage, direct test of the cable insulation without violating the protective jacket becomes problematic. This report addresses the range of bulk electrical NDE cable tests that are or could be practically implemented in a field-test situation with a particular focus on frequency domain reflectometry (FDR). The FDR test method offers numerous

  13. 1. GENERAL VIEW OF SLC3W SHOWING SOUTH FACE AND EAST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. GENERAL VIEW OF SLC-3W SHOWING SOUTH FACE AND EAST SIDE OF A-FRAME MOBILE SERVICE TOWER (MST). MST IN SERVICE POSITION OVER LAUNCHER AND FLAME BUCKET. CABLE TRAYS BETWEEN LAUNCH OPERATIONS BUILDING (BLDG. 763) AND SLC-3W IN FOREGROUND. LIQUID OXYGEN APRON VISIBLE IMMEDIATELY EAST (RIGHT) OF MST; FUEL APRON VISIBLE IMMEDIATELY WEST (LEFT) OF MST. A PORTION OF THE FLAME BUCKET VISIBLE BELOW THE SOUTH FACE OF THE MST. CAMERA TOWERS VISIBLE EAST OF MST BETWEEN ROAD AND CABLE TRAY, AND SOUTH OF MST NEAR LEFT MARGIN OF PHOTOGRAPH. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  14. Self-healing cable for extreme environments

    NASA Technical Reports Server (NTRS)

    Huston, Dryver R. (Inventor); Tolmie, Bernard R. (Inventor)

    2009-01-01

    Self-healing cable apparatus and methods disclosed. The self-healing cable has a central core surrounded by an adaptive cover that can extend over the entire length of the self-healing cable or just one or more portions of the self-healing cable. The adaptive cover includes an axially and/or radially compressible-expandable (C/E) foam layer that maintains its properties over a wide range of environmental conditions. A tape layer surrounds the C/E layer and is applied so that it surrounds and axially and/or radially compresses the C/E layer. When the self-healing cable is subjected to a damaging force that causes a breach in the outer jacket and the tape layer, the corresponding localized axially and/or radially compressed portion of the C/E foam layer expands into the breach to form a corresponding localized self-healed region. The self-healing cable is manufacturable with present-day commercial self-healing cable manufacturing tools.

  15. Analytical and numerical construction of equivalent cables.

    PubMed

    Lindsay, K A; Rosenberg, J R; Tucker, G

    2003-08-01

    The mathematical complexity experienced when applying cable theory to arbitrarily branched dendrites has lead to the development of a simple representation of any branched dendrite called the equivalent cable. The equivalent cable is an unbranched model of a dendrite and a one-to-one mapping of potentials and currents on the branched model to those on the unbranched model, and vice versa. The piecewise uniform cable, with a symmetrised tri-diagonal system matrix, is shown to represent the canonical form for an equivalent cable. Through a novel application of the Laplace transform it is demonstrated that an arbitrary branched model of a dendrite can be transformed to the canonical form of an equivalent cable. The characteristic properties of the equivalent cable are extracted from the matrix for the transformed branched model. The one-to-one mapping follows automatically from the construction of the equivalent cable. The equivalent cable is used to provide a new procedure for characterising the location of synaptic contacts on spinal interneurons.

  16. The Cable Fable.

    ERIC Educational Resources Information Center

    Kalba, Kas, Ed.

    1972-01-01

    An entire issue of the "Yale Review of Law and Social Action" has been devoted to 12 articles providing views on potential benefits and pitfalls of cable television in contrast to the picture provided by the Sloan Commission Report. The goal further unifying these articles is that of waging the argument for an expanded cable television policy.…

  17. On the Cable; The Television of Abundance. Report of the Sloan Commission on Cable Communications.

    ERIC Educational Resources Information Center

    Alfred P. Sloan Foundation, New York, NY.

    The Sloan Commission report on cable television surveys the history and technology of cable television and suggests the prospects and possibilities the medium offers to the American public. The possible impact of cable television on over-the-air television is projected, and the possible shape of entertainment, news and opinion, public services,…

  18. Spread potential of binucleate Rhizoctonia from propagation floors to trays containing stem cuttings

    USDA-ARS?s Scientific Manuscript database

    Binucelate Rhizoctonia spp. (BNR), the cause of web blight, are present all year on container-grown azaleas in the southern U.S. BNR can be eliminated during vegetative propagation by submerging stem cuttings in 50°C water for 21 minutes. The objective was to evaluate risk of rooting trays bein...

  19. Superconducting flat tape cable magnet

    DOEpatents

    Takayasu, Makoto

    2015-08-11

    A method for winding a coil magnet with the stacked tape cables, and a coil so wound. The winding process is controlled and various shape coils can be wound by twisting about the longitudinal axis of the cable and bending following the easy bend direction during winding, so that sharp local bending can be obtained by adjusting the twist pitch. Stack-tape cable is twisted while being wound, instead of being twisted in a straight configuration and then wound. In certain embodiments, the straight length should be half of the cable twist-pitch or a multiple of it.

  20. 47 CFR 27.1202 - Cable/BRS cross-ownership.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... portion of the franchise area actually served by the cable operator's cable system and the cable operator... franchise area actually served by the cable operator's cable system the cable operator will use the BRS... that no portion of the GSA of the BRS station is within the portion of the franchise area actually...

  1. 47 CFR 27.1202 - Cable/BRS cross-ownership.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... portion of the franchise area actually served by the cable operator's cable system and the cable operator... franchise area actually served by the cable operator's cable system the cable operator will use the BRS... that no portion of the GSA of the BRS station is within the portion of the franchise area actually...

  2. 47 CFR 27.1202 - Cable/BRS cross-ownership.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... portion of the franchise area actually served by the cable operator's cable system and the cable operator... franchise area actually served by the cable operator's cable system the cable operator will use the BRS... that no portion of the GSA of the BRS station is within the portion of the franchise area actually...

  3. 47 CFR 27.1202 - Cable/BRS cross-ownership.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... portion of the franchise area actually served by the cable operator's cable system and the cable operator... franchise area actually served by the cable operator's cable system the cable operator will use the BRS... that no portion of the GSA of the BRS station is within the portion of the franchise area actually...

  4. Flat conductor cable design, manufacture, and installation

    NASA Technical Reports Server (NTRS)

    Angele, W.; Hankins, J. D.

    1973-01-01

    Pertinent information for hardware selection, design, manufacture, and quality control necessary for flat conductor cable interconnecting harness application is presented. Comparisons are made between round wire cable and flat conductor cable. The flat conductor cable interconnecting harness systems show major cost, weight, and space savings, plus increased system performance and reliability. The design application section includes electrical characteristics, harness design and development, and a full treatise on EMC considerations. Manufacturing and quality control sections pertain primarily to the developed conductor-contact connector system and special flat conductor cable to round wire cable transitions.

  5. 30 CFR 75.827 - Guarding of trailing cables.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... grounded metal. (b) Suspended cables and cable crossovers. When equipment must cross any portion of the cable, the cable must be either: (1) Suspended from the mine roof; or (2) Protected by a cable crossover...

  6. 30 CFR 75.827 - Guarding of trailing cables.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... grounded metal. (b) Suspended cables and cable crossovers. When equipment must cross any portion of the cable, the cable must be either: (1) Suspended from the mine roof; or (2) Protected by a cable crossover...

  7. 30 CFR 75.827 - Guarding of trailing cables.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... grounded metal. (b) Suspended cables and cable crossovers. When equipment must cross any portion of the cable, the cable must be either: (1) Suspended from the mine roof; or (2) Protected by a cable crossover...

  8. 30 CFR 75.827 - Guarding of trailing cables.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... grounded metal. (b) Suspended cables and cable crossovers. When equipment must cross any portion of the cable, the cable must be either: (1) Suspended from the mine roof; or (2) Protected by a cable crossover...

  9. Power superconducting power transmission cable

    DOEpatents

    Ashworth, Stephen P.

    2003-06-10

    The present invention is for a compact superconducting power transmission cable operating at distribution level voltages. The superconducting cable is a conductor with a number of tapes assembled into a subconductor. These conductors are then mounted co-planarly in an elongated dielectric to produce a 3-phase cable. The arrangement increases the magnetic field parallel to the tapes thereby reducing ac losses.

  10. Power superconducting power transmission cable

    DOEpatents

    Ashworth, Stephen P.

    2003-01-01

    The present invention is for a compact superconducting power transmission cable operating at distribution level voltages. The superconducting cable is a conductor with a number of tapes assembled into a subconductor. These conductors are then mounted co-planarly in an elongated dielectric to produce a 3-phase cable. The arrangement increases the magnetic field parallel to the tapes thereby reducing ac losses.

  11. Implementing Adlerian Sand Tray Therapy with Adult Male Substance Abuse Offenders: A Phenomenological Inquiry

    ERIC Educational Resources Information Center

    Monakes, Sarah; Garza, Yvonne; Wiesner, Van, III; Watts, Richard E.

    2011-01-01

    The purpose of this phenomenological study was to understand the perceptions of adult male substance offenders who experienced sand tray therapy as an adjunct to their cognitive behavioral rehabilitative treatment. Results indicate a positive experience for participants. Implications for counselors are discussed. (Contains 1 table.)

  12. Correction coil cable

    DOEpatents

    Wang, Sou-Tien

    1994-11-01

    A wire cable assembly (10, 310) adapted for the winding of electrical coils is taught. A primary intended use is for use in particle tube assemblies (532) for the superconducting super collider. The correction coil cables (10, 310) have wires (14, 314) collected in wire arrays (12, 312) with a center rib (16, 316) sandwiched therebetween to form a core assembly (18, 318 ). The core assembly (18, 318) is surrounded by an assembly housing (20, 320) having an inner spiral wrap (22, 322) and a counter wound outer spiral wrap (24, 324). An alternate embodiment (410) of the invention is rolled into a keystoned shape to improve radial alignment of the correction coil cable (410) on a particle tube (733) in a particle tube assembly (732).

  13. Grounding and Shielding Requirements for the Radiation and EMP Environments of an Underground Nuclear Test

    DTIC Science & Technology

    1978-03-17

    the trailers as Electro-magnetic Interference ( EMI ) tight as possible; such items included removal of all unnecessary wiring penetrations, conductive...20 12. CABLE TRAYS, GROUT-FILLED ............ .................. 21 13. THE MESA TRAILER PARK CONSIDERATIONS...enclosed cable shields. 12. The mesa trailer park received some attention regarding the GSP, although not as intense as the tunnel environment. Specifically

  14. RODENT RESISTANT CABLE MATERIALS.

    DTIC Science & Technology

    Several formulations of organotin compounds in polymeric materials were evaluated for application to polyethylene cable coatings. Tributyltin ...test the effectiveness of this formulation in protecting treated WF-16 cable from rodent damage. In a laboratory test vapors of tributyltin chloride

  15. Fiber optic cables for severe environment

    NASA Astrophysics Data System (ADS)

    Massarani, M. G.

    1982-10-01

    The most severe challenges to the fiber optic cable are related to nuclear weapons testing and other military applications. Nuclear experiments are conducted in deep underground holes. Cables connect the experimental device to recording stations positioned at a certain distance from ground zero. Attractive features provided by fiber optic cable technology include large cost advantages in cable purchase price, savings in handling cost due to the lighter weight, immunity to electromagnetic pulses (EMP), and the capability to transmit high data rates. Details of underground nuclear testing are discussed, taking into account the underground nuclear test environment, and questions of fiber optic cable design for the underground experiments. The use of fiber optics for the Ground Launched Cruise Missile Weapons System (GLCM) is also considered. Attention is given to the GLCM environment, and the proposed cable for GLCM application.

  16. Strain-Gauge Measurement of Weight of Fluid in a Tank

    NASA Technical Reports Server (NTRS)

    Figueroa, Jorge; SaintCyr, William; Rahman, Shamim; McVay, Gregory; VanDyke, David; Mitchell, William; Langford, Lester

    2003-01-01

    A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods). The strain gauges used in this method are of two types: foil and fiber-optic. Four foil gauges and one or more fiber-optic gauges are mounted on each of the tank-supporting legs. An additional fiber-optic gauge is mounted on an object, made of the same material as that of the tank-supporting legs, that is not subjected to any mechanical load. The reading obtained by the additional fiber-optic gauge is used to compensate for apparent strains caused by changes in temperature. The signals from the foil and fiber-optic gauges are conditioned, then digitized for input to a computer. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation. At the time of reporting the information for this article, a set of foil gauges had been tested on the supports of a 500-gallon (1,900-liter) tank. The gauges were found to be capable of measuring the deformations (up to 22 microstrain) that occurred during filling and emptying the

  17. The use of 3D-printed titanium mesh tray in treating complex comminuted mandibular fractures

    PubMed Central

    Ma, Junli; Ma, Limin; Wang, Zhifa; Zhu, Xiongjie; Wang, Weijian

    2017-01-01

    Abstract Rationale: Precise bony reduction and reconstruction of optimal contour in treating comminuted mandibular fractures is very difficult using traditional techniques and devices. The aim of this report is to introduce our experiences in using virtual surgery and three-dimensional (3D) printing technique in treating this clinical challenge. Patient concerns: A 26-year-old man presented with severe trauma in the maxillofacial area due to fall from height. Diagnosis: Computed tomography images revealed middle face fractures and comminuted mandibular fracture including bilateral condyles. Interventions and outcomes: The computed tomography data was used to construct the 3D cranio-maxillofacial models; then the displaced bone fragments were virtually reduced. On the basis of the finalized model, a customized titanium mesh tray was designed and fabricated using selective laser melting technology. During the surgery, a submandibular approach was adopted to repair the mandibular fracture. The reduction and fixation were performed according to preoperative plan, the bone defects in the mental area were reconstructed with iliac bone graft. The 3D-printed mesh tray served as an intraoperative template and carrier of bone graft. The healing process was uneventful, and the patient was satisfied with the mandible contour. Lessons: Virtual surgical planning combined with 3D printing technology enables surgeon to visualize the reduction process preoperatively and guide intraoperative reduction, making the reduction less time consuming and more precise. 3D-printed titanium mesh tray can provide more satisfactory esthetic outcomes in treating complex comminuted mandibular fractures. PMID:28682875

  18. Computational study of the heat transfer of an avian egg in a tray.

    PubMed

    Eren Ozcan, S; Andriessens, S; Berckmans, D

    2010-04-01

    The development of an embryo in an avian egg depends largely on its temperature. The embryo temperature is affected by its environment and the heat produced by the egg. In this paper, eggshell temperature and the heat transfer characteristics from one egg in a tray toward its environment are studied by means of computational fluid dynamics (CFD). Computational fluid dynamics simulations have the advantage of providing extensive 3-dimensional information on velocity and eggshell temperature distribution around an egg that otherwise is not possible to obtain by experiments. However, CFD results need to be validated against experimental data. The objectives were (1) to find out whether CFD can successfully simulate eggshell temperature from one egg in a tray by comparing to previously conducted experiments, (2) to visualize air flow and air temperature distribution around the egg in a detailed way, and (3) to perform sensitivity analysis on several variables affecting heat transfer. To this end, a CFD model was validated using 2 sets of temperature measurements yielding an effective model. From these simulations, it can be concluded that CFD can effectively be used to analyze heat transfer characteristics and eggshell temperature distribution around an egg. In addition, air flow and temperature distribution around the egg are visualized. It has been observed that temperature differences up to 2.6 degrees C are possible at high heat production (285 mW) and horizontal low flow rates (0.5 m/s). Sensitivity analysis indicates that average eggshell temperature is mainly affected by the inlet air velocity and temperature, flow direction, and the metabolic heat of the embryo and less by the thermal conductivity and emissivity of the egg and thermal emissivity of the tray.

  19. Debris protection cover assembly for cable connectors

    NASA Technical Reports Server (NTRS)

    Yovan, Roger D. (Inventor)

    1999-01-01

    A protective cover assembly for an end of a cable connector having a cable housing that encloses a plurality of connective pins or sockets and that satisfies all requirements for space applications. A connector body flange is formed at the extremity of a cable and is positioned so that it may register with a corresponding connector body flange on the end of a companion cable to which a connection is to be made, one cable end having cable lead pins and the companion cable end having lead sockets with which the pins register. A latch mechanism having a latch housing is received in the connector body flange and a crank connected to a manually rotatable cap actuates a spring-loaded latch element that is engageable with a connector body flange to secure or to release the cover assembly with the simple twisting motion of the cap, thereby simplifying the task of effecting coupling and decoupling of the cable ends.

  20. The analysis of cable forces based on natural frequency

    NASA Astrophysics Data System (ADS)

    Suangga, Made; Hidayat, Irpan; Juliastuti; Bontan, Darwin Julius

    2017-12-01

    A cable is a flexible structural member that is effective at resisting tensile forces. Cables are used in a variety of structures that employ their unique characteristics to create efficient design tension members. The condition of the cable forces in the cable supported structure is an important indication of judging whether the structure is in good condition. Several methods have been developed to measure on site cable forces. Vibration technique using correlation between natural frequency and cable forces is a simple method to determine in situ cable forces, however the method need accurate information on the boundary condition, cable mass, and cable length. The natural frequency of the cable is determined using FFT (Fast Fourier Transform) Technique to the acceleration record of the cable. Based on the natural frequency obtained, the cable forces then can be determine by analytical or by finite element program. This research is focus on the vibration techniques to determine the cable forces, to understand the physical parameter effect of the cable and also modelling techniques to the natural frequency and cable forces.

  1. Cable Bacteria in Freshwater Sediments

    PubMed Central

    Kristiansen, Michael; Frederiksen, Rasmus B.; Dittmer, Anders Lindequist; Bjerg, Jesper Tataru; Trojan, Daniela; Schreiber, Lars; Damgaard, Lars Riis; Schramm, Andreas; Nielsen, Lars Peter

    2015-01-01

    In marine sediments cathodic oxygen reduction at the sediment surface can be coupled to anodic sulfide oxidation in deeper anoxic layers through electrical currents mediated by filamentous, multicellular bacteria of the Desulfobulbaceae family, the so-called cable bacteria. Until now, cable bacteria have only been reported from marine environments. In this study, we demonstrate that cable bacteria also occur in freshwater sediments. In a first step, homogenized sediment collected from the freshwater stream Giber Å, Denmark, was incubated in the laboratory. After 2 weeks, pH signatures and electric fields indicated electron transfer between vertically separated anodic and cathodic half-reactions. Fluorescence in situ hybridization revealed the presence of Desulfobulbaceae filaments. In addition, in situ measurements of oxygen, pH, and electric potential distributions in the waterlogged banks of Giber Å demonstrated the presence of distant electric redox coupling in naturally occurring freshwater sediment. At the same site, filamentous Desulfobulbaceae with cable bacterium morphology were found to be present. Their 16S rRNA gene sequence placed them as a distinct sister group to the known marine cable bacteria, with the genus Desulfobulbus as the closest cultured lineage. The results of the present study indicate that electric currents mediated by cable bacteria could be important for the biogeochemistry in many more environments than anticipated thus far and suggest a common evolutionary origin of the cable phenotype within Desulfobulbaceae with subsequent diversification into a freshwater and a marine lineage. PMID:26116678

  2. 30 CFR 75.602 - Trailing cable junctions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Trailing cable junctions. 75.602 Section 75.602... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Trailing Cables § 75.602 Trailing cable junctions. [Statutory Provision] When two or more trailing cables junction to the same distribution center, means shall...

  3. Impact of Cross-Tie Properties on the Modal Behavior of Cable Networks on Cable-Stayed Bridges

    PubMed Central

    Ahmad, Javaid; Ghrib, Faouzi

    2015-01-01

    Dynamic behaviour of cable networks is highly dependent on the installation location, stiffness, and damping of cross-ties. Thus, these are the important design parameters for a cable network. While the effects of the former two on the network response have been investigated to some extent in the past, the impact of cross-tie damping has rarely been addressed. To comprehend our knowledge of mechanics associated with cable networks, in the current study, an analytical model of a cable network will be proposed by taking into account both cross-tie stiffness and damping. In addition, the damping property of main cables in the network will also be considered in the formulation. This would allow exploring not only the effectiveness of a cross-tie design on enhancing the in-plane stiffness of a constituted cable network, but also its energy dissipation capacity. The proposed analytical model will be applied to networks with different configurations. The influence of cross-tie stiffness and damping on the modal response of various types of networks will be investigated by using the corresponding undamped rigid cross-tie network as a reference base. Results will provide valuable information on the selection of cross-tie properties to achieve more effective cable vibration control. PMID:26167539

  4. Impact of Cross-Tie Properties on the Modal Behavior of Cable Networks on Cable-Stayed Bridges.

    PubMed

    Ahmad, Javaid; Cheng, Shaohong; Ghrib, Faouzi

    2015-01-01

    Dynamic behaviour of cable networks is highly dependent on the installation location, stiffness, and damping of cross-ties. Thus, these are the important design parameters for a cable network. While the effects of the former two on the network response have been investigated to some extent in the past, the impact of cross-tie damping has rarely been addressed. To comprehend our knowledge of mechanics associated with cable networks, in the current study, an analytical model of a cable network will be proposed by taking into account both cross-tie stiffness and damping. In addition, the damping property of main cables in the network will also be considered in the formulation. This would allow exploring not only the effectiveness of a cross-tie design on enhancing the in-plane stiffness of a constituted cable network, but also its energy dissipation capacity. The proposed analytical model will be applied to networks with different configurations. The influence of cross-tie stiffness and damping on the modal response of various types of networks will be investigated by using the corresponding undamped rigid cross-tie network as a reference base. Results will provide valuable information on the selection of cross-tie properties to achieve more effective cable vibration control.

  5. 30 CFR 57.12088 - Splicing trailing cables.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... cable reel or other power feed cable payout-retrieval system. However, a temporary splice may be made to... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Splicing trailing cables. 57.12088 Section 57... Underground Only § 57.12088 Splicing trailing cables. No splice, except a vulcanized splice or its equivalent...

  6. 30 CFR 57.12088 - Splicing trailing cables.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... cable reel or other power feed cable payout-retrieval system. However, a temporary splice may be made to... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Splicing trailing cables. 57.12088 Section 57... Underground Only § 57.12088 Splicing trailing cables. No splice, except a vulcanized splice or its equivalent...

  7. 30 CFR 57.12088 - Splicing trailing cables.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... cable reel or other power feed cable payout-retrieval system. However, a temporary splice may be made to... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Splicing trailing cables. 57.12088 Section 57... Underground Only § 57.12088 Splicing trailing cables. No splice, except a vulcanized splice or its equivalent...

  8. 30 CFR 57.12088 - Splicing trailing cables.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... cable reel or other power feed cable payout-retrieval system. However, a temporary splice may be made to... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Splicing trailing cables. 57.12088 Section 57... Underground Only § 57.12088 Splicing trailing cables. No splice, except a vulcanized splice or its equivalent...

  9. Spacecraft materials studies on the Aerospace Corporation tray on EOIM-3

    NASA Technical Reports Server (NTRS)

    Stuckey, Wayne K.; Hemminger, Carol S.; Steckel, Gary L.; Hills, Malina M.; Hilton, Michael R.

    1995-01-01

    A passive tray was flown on the Effects of Oxygen Interaction with Materials experiment on STS-46 (EOIM-3) with 82 samples from The Aerospace Corporation. A variety of advanced materials related to potential uses on future spacecraft were included for evaluation representing optical coatings, lubricants, polymers, composites, carbon-carbon composite protective coatings, graphite protective coatings, thermal-control materials, and some samples of current materials. An overview of the available results from the investigations of these materials is presented.

  10. 30 CFR 57.12014 - Handling energized power cables.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Handling energized power cables. 57.12014... Electricity Surface and Underground § 57.12014 Handling energized power cables. Power cables energized to.... This does not prohibit pulling or dragging of cable by the equipment it powers when the cable is...

  11. 30 CFR 57.12014 - Handling energized power cables.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Handling energized power cables. 57.12014... Electricity Surface and Underground § 57.12014 Handling energized power cables. Power cables energized to.... This does not prohibit pulling or dragging of cable by the equipment it powers when the cable is...

  12. 30 CFR 57.12014 - Handling energized power cables.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Handling energized power cables. 57.12014... Electricity Surface and Underground § 57.12014 Handling energized power cables. Power cables energized to.... This does not prohibit pulling or dragging of cable by the equipment it powers when the cable is...

  13. 30 CFR 57.12014 - Handling energized power cables.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Handling energized power cables. 57.12014... Electricity Surface and Underground § 57.12014 Handling energized power cables. Power cables energized to.... This does not prohibit pulling or dragging of cable by the equipment it powers when the cable is...

  14. 30 CFR 57.12014 - Handling energized power cables.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Handling energized power cables. 57.12014... Electricity Surface and Underground § 57.12014 Handling energized power cables. Power cables energized to.... This does not prohibit pulling or dragging of cable by the equipment it powers when the cable is...

  15. Submarine cable OBS using a retired submarine telecommunication cable: GeO-TOC program

    NASA Astrophysics Data System (ADS)

    Kasahara, Junzo; Utada, Hisashi; Sato, Toshinori; Kinoshita, Hajimu

    1998-06-01

    In order to study the Earth's structure and subduction zone tectonics, seismic data from the oceanic region are extremely important. The present seismograph distribution in the oceanic region, however, provides a very poor coverage. To improve this poor seismic coverage, a cable OBS system using a retired submarine telecommunication cable is proposed. The GeO-TOC cable runs from Ninomiya, Japan, to Guam through the Izu-Bonin forearc and the Marina Trough. The total length of the cable is 2659 km. An OBS, IZU, using the GeO-TOC cable, was successfully installed at the landward slope of the Izu-Bonin Trench in January 1997. The IZU OBS is located approximately 400 km south of Tokyo. The installation method is similar to repair work on submarine cables. The IZU OBS is equipped with three accelerometers, a hydrophone, a quartz pressure gauge, and a quartz precision thermometer with a few temperature sensors to monitor overheating of the internal electronics. After installation, the voltage increase is 90 V when the current is maintained at a constant 370 mA. Data from accelerometers are digitized by 24-bit A/D converters and sent to Ninomiya at 9600 bps for each component. Hydrophone data are sent to Ninomiya as analog signals using the AM (Amplitude Modulation) method for safety reasons. Hydrophone data are digitized at the shore station. Other slow-rate data are multiplexed and sent to the shore at 9600 bps. The instrument can be controlled by a shore computer. All data will be transmitted from Ninomiya to Tokyo and combined with other existing seismic data.

  16. Strain relief for power-cable connectors

    NASA Technical Reports Server (NTRS)

    Dean, W. T., III

    1980-01-01

    Easily fabricated grommet composed of polytetrafluoroethylene cylinder, containing U-shaped channels equally spaced around periphery, is used in power cable connectors to relieve strain on cables. Utilization of grommets provides more ease in cable insertion and removal. Potential applications include wiring in large residential and commercial buildings.

  17. Cable Television Report and Suggested Ordinance.

    ERIC Educational Resources Information Center

    League of California Cities, Sacramento.

    Guidelines and suggested ordinances for cable television regulation by local governments are comprehensively discussed in this report. The emphasis is placed on franchising the cable operator. Seventeen legal aspects of franchising are reviewed, and an exemplary ordinance is presented. In addition, current statistics about cable franchising in…

  18. Initial tension loss in cerclage cables.

    PubMed

    Ménard, Jérémie; Émard, Maxime; Canet, Fanny; Brailovski, Vladimir; Petit, Yvan; Laflamme, George Y

    2013-10-01

    Cerclage cables, frequently used in the management of fractures and osteotomies, are associated with a high failure rate and significant loosening during surgery. This study compared the capacity to maintain tension of different types of orthopaedic cable systems. Multifilament Cobalt-Chrome (CoCr) cables with four different crimp/clamp devices (DePuy, Stryker, Zimmer and Smith&Nephew) and one non-metallic Nylon (Ny) cable from Kinamed were instrumented with a load cell to measure tension during insertion. Significant tension loss was observed with crimping for all cables (P<0.05). Removing the tensioner led to an additional unexpected tension loss (CoCr-DePuy: 18%, CoCr-Stryker: 29%, CoCr-Smith&Nephew: 33%, Ny: 46%, and CoCr-Zimmer: 52%). The simple CoCr (DePuy) cable system outperformed the more sophisticated locking devices due to its significantly better ability to prevent tension loss. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Effect of Concrete Creep on the displacement of single tower single cable plane Extradosed Cable-stayed Bridge

    NASA Astrophysics Data System (ADS)

    Shi, Jing-xian; Ran, Zhi-hong

    2018-03-01

    Extradossed Cable-stayed Bridge is both cable-stayed Bridge and Continuous rigid frame bridge mechanics feature, Beam is the main force components, cable is supplement.This article combined with a single tower and single cable plane Extradossed cable-stayed bridge in Yunnan, use different creep calculation models and analysis deflection caused by creep effects. The results showing that deflection caused by creep effect is smaller than the same span continuous rigid frame bridge, the value is about 2cm. On the other hand the deflection is increasing with ambient humidity decreases, therefore in the dry environment the calculation model is relatively large in the pre-camber. In the choice of RC creep model is significant in the dry areas.

  20. Development and Testing of a Mobile Platform for Tank Remediation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nance, T.A.

    2001-01-16

    The Department of Energy (DOE) is committed to removing millions of gallons of high level radioactive waste from waste storage tanks at the Savannah River Site (SRS). SRS was the first site in the DOE complex to have emptied and closed high level waste tanks. Tank closure at the Site is now progressing to tanks containing waste composed of liquid and large deposits of solids, including a tank that has a potential ''heel''. A heel is a hardened mass of solid waste material spread across the tank bottom. Tank closure requires breaking up this heel and moving the material tomore » the intake of a pumping system for transfer from the tank. In the past, overhead spray systems have been used with some success at moving waste. But the limited number of risers restricts the coverage area of the overhead spray system. Therefore, a floor- level spray system will be used to separate manageable size chunks of the material from the heel. The chunks will be guided into the pump's intake to be remove from the tank. The floor-level spray system movement will be accomplished by using a mobile platform, a crawler, which provides transport to nearly every point on the tank floor. Transport of the spray system will allow the system to ''corral'' the waste away from the tank walls and control the movement of the material across the tank floor. Because the available access riser is small, and a wide crawler platform is required to support the spray system, the crawler's frame must fold to enter the tank. After entry into the tank, the crawler unfolds on the tank floor using the crawler drive tracks to expand the frame and position the mobile platform under the entry riser. The spray system will then be lowered separately through the entry riser and mated onto the crawler on the tank floor. The crawler and spray system are tethered and controlled remotely by personnel at the control station. Motorized cable reels will also be remotely controlled to pay out, retrieve, and manage the

  1. 30 CFR 75.828 - Trailing cable pulling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Trailing cable pulling. 75.828 Section 75.828... Longwalls § 75.828 Trailing cable pulling. The trailing cable must be de-energized prior to being pulled by... procedures must be followed when pulling the trailing cable with equipment other than the continuous mining...

  2. 46 CFR 111.60-5 - Cable installation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... REQUIREMENTS Wiring Materials and Methods § 111.60-5 Cable installation. (a) Each cable installation must meet... 46 Shipping 4 2010-10-01 2010-10-01 false Cable installation. 111.60-5 Section 111.60-5 Shipping... incorporated by reference; see 46 CFR 110.10-1), including clause 8. (b) Each cable installation made in...

  3. Rotating Connection for Electrical Cables

    NASA Technical Reports Server (NTRS)

    Manges, D. R.

    1986-01-01

    Cable reel provides electrical connections between fixed structure and rotating one. Reel carries power and signal lines while allowing rotating structure to turn up to 360 degrees with respect to fixed structure. Reel replaces sliprings. Can be used to electrically connect arm of robot with body. Reel releases cable to rotating part as it turns and takes up cable as rotating part comes back to its starting position, without tangling, twisting, or kinking.

  4. Superconducting Cable Termination

    DOEpatents

    Sinha, Uday K.; Tolbert, Jerry

    2005-08-30

    Disclosed is a termination that connects high temperature superconducting (HTS) cable immersed in pressurized liquid nitrogen to high voltage and neutral (shield) external bushings at ambient temperature and pressure. The termination consists of a splice between the HTS power (inner) and shield (outer) conductors and concentric copper pipes which are the conductors in the termination. There is also a transition from the dielectric tape insulator used in the HTS cable to the insulators used between and around the copper pipe conductors in the termination. At the warm end of the termination the copper pipes are connected via copper braided straps to the conventional warm external bushings which have low thermal stresses. This termination allows for a natural temperature gradient in the copper pipe conductors inside the termination which enables the controlled flashing of the pressurized liquid coolant (nitrogen) to the gaseous state. Thus the entire termination is near the coolant supply pressure and the high voltage and shield cold bushings, a highly stressed component used in most HTS cables, are eliminated. A sliding seal allows for cable contraction as it is cooled from room temperature to ˜72-82 K. Seals, static vacuum, and multi-layer superinsulation minimize radial heat leak to the environment.

  5. The Humanistic Claim on the Cable. Workshop on Uses of the Cable.

    ERIC Educational Resources Information Center

    Adler, Richard

    In recent years, the cable television industry has been marked by prolific growth both in the number of stations and in the number of subscribers, and its legitimacy has been affirmed by a Supreme Court decision which placed the industry under the control of the Federal Communications Commission, (FCC) but the full potential of cable television…

  6. Cable-to-post attachments for a non-proprietary high-tension cable barrier - phase II.

    DOT National Transportation Integrated Search

    2015-06-01

    The research objectives reported herein were based on further development of cable-to-post attachment hardware for use in : the non-proprietary high-tension cable barrier system. Specifically, this project aimed to develop and evaluate alternative : ...

  7. Reusable Hot-Wire Cable Cutter

    NASA Technical Reports Server (NTRS)

    Pauken, Michael T.; Steinkraus, Joel M.

    2010-01-01

    During the early development stage of balloon deployment systems for missions, nichrome wire cable cutters were often used in place of pyro-actuated cutters. Typically, a nichrome wire is wrapped around a bundle of polymer cables with a low melting point and connected to a relay-actuated electric circuit. The heat from the nichrome reduces the strength of the cable bundle, which quickly breaks under a mechanical load and can thus be used as a release mechanism for a deployment system. However, the use of hand-made heated nichrome wire for cutters is not very reliable. Often, the wrapped nichrome wire does not cut through the cable because it either pulls away from its power source or does not stay in contact with the cable being cut. Because nichrome is not readily soldered to copper wire, unreliable mechanical crimps are often made to connect the nichrome to an electric circuit. A self-contained device that is reusable and reliable was developed to sever cables for device release or deployment. The nichrome wire in this new device is housed within an enclosure to prevent it from being damaged by handling. The electric power leads are internally connected within the unit to the nichrome wire using a screw terminal connection. A bayonet plug, a quick and secure method of connecting the cutter to the power source, is used to connect the cutter to the power leads similar to those used in pyro-cutter devices. A small ceramic tube [0.25-in. wide 0.5-in. long (.6.4-mm wide 13-mm long)] houses a spiraled nichrome wire that is heated when a cable release action is required. The wire is formed into a spiral coil by wrapping it around a mandrel. It is then laid inside the ceramic tube so that it fits closely to the inner surface of the tube. The ceramic tube provides some thermal and electrical insulation so that most of the heat generated by the wire is directed toward the cable bundle in the center of the spiral. The ceramic tube is cemented into an aluminum block, which

  8. A novel open-tray impression technique for fabrication of a provisional prosthesis on immediate load implants in a completely edentulous arch.

    PubMed

    Kaneko, Takahiro; Yamagishi, Kiyoshi; Horie, Norio; Shimoyama, Tetsuo

    2013-01-01

    To evaluate the clinical outcome of a novel open-tray impression technique for fabrication of a provisional prosthesis supported by immediately loaded implants in a completely edentulous arch. An open-tray impression technique was evaluated in this retrospective study that included patients treated between March 2006 and October 2009. Preoperatively, a diagnostic prosthesis was delivered, and a novel open tray was fabricated based on this prosthesis. After implant placement, the impression and interocclusal record were taken simultaneously using the novel open tray. Laboratory-fabricated, screw-retained, all-acrylic resin provisional restorations were delivered on the same day of surgery. The prosthesis was assessed from the day of surgery until replacement with a definitive prosthesis. The study included 21 patients (mean age, 64.5 years) and a total of 125 implants. Of these, 104 implants were immediately loaded. In all patients, well-fitting provisional restorations supported by a minimum of four implants were delivered. Fracture of the first molar cusp was observed in one case after 30 days. However, there was no extensive fracture in the framework or functional disorder of the prosthesis. No implant failed during the follow-up after implant surgery. This protocol enabled fabrication of a well-fitting acrylic resin provisional prosthesis supported by immediately loaded implants because the impression was taken while in centric occlusion and an occlusion identical to the diagnostic prosthesis could be reconstructed.

  9. Cable: Report to the President, 1974.

    ERIC Educational Resources Information Center

    Office of Telecommunications Policy, Washington, DC.

    A comprehensive, new national policy for cable communications is recommended by the Cabinet Committee on Cable Communications. The goal of the policy is to achieve the orderly integration of cable with other existing communications media so that information may flow freely, protected from both private and governmental barriers. The first two…

  10. Reducing Magnetic Fields Around Power Cables

    NASA Technical Reports Server (NTRS)

    Sargent, Noel B.; Gitelman, Florida; Pongracz-Bartha, Edward; Spalding, John

    1993-01-01

    Four power conductors arranged symmetrically about fifth grounded conductor. Four current-carrying wires arranged symmetrically around central grounded wire that nominally carries no current. In comparison with other cable configurations, this one results in smaller magnetic fields around cable. Technique for use when size of wires in cable makes twisting impractical.

  11. Hypervelocity impact testing of cables

    NASA Technical Reports Server (NTRS)

    Jex, D. W.; Adkinson, A. B.; English, J. E.; Linebaugh, C. E.

    1973-01-01

    The physics and electrical results obtained from simulated micrometeoroid testing of certain Skylab cables are presented. The test procedure, electrical circuits, test equipment, and cable types utilized are also explained.

  12. Robot cable-compliant devices

    NASA Technical Reports Server (NTRS)

    Kerley, James J., Jr. (Inventor)

    1990-01-01

    A cable compliant robotic joint includes two U configuration cross section brackets with their U cross sections lying in different planes, one of their brackets being connected to a robot arm and the other to a tool. Additional angle brackets are displaced from the other brackets at corners of the robotic joint. All the brackets are connected by cable segments which lie in one or more planes which are perpendicular to the direction of tool travel as it approaches a work object. The compliance of the joint is determined by the cable segment characteristics, such as their length, material, angle, stranding, pretwisting, and prestressing.

  13. 30 CFR 77.505 - Cable fittings; suitability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Electrical Equipment-General § 77.505 Cable fittings; suitability. Cables shall enter metal frames of motors... cables, pass through metal frames, the holes shall be substantially bushed with insulated bushings. ...

  14. 47 CFR 32.2426 - Intrabuilding network cable.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Nonmetallic cable. This subsidiary record category shall include the original cost of optical fiber cable and... between buildings on one customer's same premises. Intrabuilding network cables are used to distribute...

  15. 47 CFR 32.2426 - Intrabuilding network cable.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Nonmetallic cable. This subsidiary record category shall include the original cost of optical fiber cable and... between buildings on one customer's same premises. Intrabuilding network cables are used to distribute...

  16. 47 CFR 32.2426 - Intrabuilding network cable.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Nonmetallic cable. This subsidiary record category shall include the original cost of optical fiber cable and... between buildings on one customer's same premises. Intrabuilding network cables are used to distribute...

  17. Active optical cable for intrasatellite communications

    NASA Astrophysics Data System (ADS)

    Blasco, J.; Cano, D.; Navasquillo, O.; Esteban, M. A.

    2017-11-01

    DAS Photonics and Airbus Defence and Space (Spain) have been working for more than six years in the concept of an Active Optical Cable (AOC) for copper cable substitution. The main advantages that AOC offers are significant mass and size saving, better flexibility and routing of the cable and immunity to EMI.

  18. 14 CFR 25.689 - Cable systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.689 Cable systems. (a... cable system must be designed so that there will be no hazardous change in cable tension throughout the... subject to load or motion and retained only by cotter pins may not be used in the control system. (e...

  19. 14 CFR 25.689 - Cable systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.689 Cable systems. (a... cable system must be designed so that there will be no hazardous change in cable tension throughout the... subject to load or motion and retained only by cotter pins may not be used in the control system. (e...

  20. 14 CFR 25.689 - Cable systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.689 Cable systems. (a... cable system must be designed so that there will be no hazardous change in cable tension throughout the... subject to load or motion and retained only by cotter pins may not be used in the control system. (e...

  1. 14 CFR 25.689 - Cable systems.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.689 Cable systems. (a... cable system must be designed so that there will be no hazardous change in cable tension throughout the... subject to load or motion and retained only by cotter pins may not be used in the control system. (e...

  2. 47 CFR 76.802 - Disposition of cable home wiring.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 4 2013-10-01 2013-10-01 false Disposition of cable home wiring. 76.802... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.802 Disposition of cable home wiring... cable operator shall not remove the cable home wiring unless it gives the subscriber the opportunity to...

  3. 47 CFR 76.802 - Disposition of cable home wiring.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Disposition of cable home wiring. 76.802... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.802 Disposition of cable home wiring... cable operator shall not remove the cable home wiring unless it gives the subscriber the opportunity to...

  4. 47 CFR 76.802 - Disposition of cable home wiring.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Disposition of cable home wiring. 76.802... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.802 Disposition of cable home wiring... cable operator shall not remove the cable home wiring unless it gives the subscriber the opportunity to...

  5. 47 CFR 76.802 - Disposition of cable home wiring.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Disposition of cable home wiring. 76.802... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.802 Disposition of cable home wiring... cable operator shall not remove the cable home wiring unless it gives the subscriber the opportunity to...

  6. Potential of spreading binucleate Rhizoctonia from nursery propagation floors to trays containing azalea stem cuttings

    USDA-ARS?s Scientific Manuscript database

    Binucleate Rhizoctonia fungi cause web blight on azaleas and other woody ornamental plants. This research focused on one aspect of how the pathogen may spread from contaminated floors of propagation houses into trays containing clean azalea stem cuttings that generate new root systems. Rhizoctonia w...

  7. Technology of Cable Television.

    ERIC Educational Resources Information Center

    Cable Television Information Center, Washington, DC.

    The technology of cable television (CATV) is one area in which local community officials need to develop knowledge so that their decisions about the structure of CATV within the community will be informed. Thus, this paper is designed to familiarize local decision makers with the technological aspects of cable communications, to isolate specific…

  8. Capacitor discharge process for welding braided cable

    DOEpatents

    Wilson, Rick D.

    1995-01-01

    A capacitor discharge process for welding a braided cable formed from a plurality of individual cable strands to a solid metallic electrically conductive member comprises the steps of: (a) preparing the electrically conductive member for welding by bevelling one of its end portions while leaving an ignition projection extending outwardly from the apex of the bevel; (b) clamping the electrically conductive member in a cathode fixture; (c) connecting the electrically conductive member clamped in the cathode fixture to a capacitor bank capable of being charged to a preselected voltage value; (d) preparing the braided cable for welding by wrapping one of its end portions with a metallic sheet to form a retaining ring operable to maintain the individual strands of the braided cable in fixed position within the retaining ring; (e) clamping the braided cable and the retaining ring as a unit in an anode fixture so that the wrapped end portion of the braided cable faces the ignition projection of the electrically conductive member; and (f) moving the cathode fixture towards the anode fixture until the ignition projection of the electrically conductive member contacts the end portion of the braided cable thereby allowing the capacitor bank to discharge through the electrically conductive member and through the braided cable and causing the electrically conductive member to be welded to the braided cable via capacitor discharge action.

  9. Noise performance of magneto-inductive cables

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiltshire, M. C. K., E-mail: michael.wiltshire@imperial.ac.uk; Syms, R. R. A.

    2014-07-21

    Magneto-inductive (MI) waveguides are metamaterial structures based on periodic arrangements of inductively coupled resonant magnetic elements. They are of interest for power transfer, communications and sensing, and can be realised in a flexible cable format. Signal-to-noise ratio is extremely important in applications involving signals. Here, we present the first experimental measurements of the noise performance of metamaterial cables. We focus on an application involving radiofrequency signal transmission in internal magnetic resonance imaging (MRI), where the subdivision of the metamaterial cable provides intrinsic patient safety. We consider MI cables suitable for use at 300 MHz during {sup 1}H MRI at 7more » T, and find noise figures of 2.3–2.8 dB/m, together with losses of 3.0–3.9 dB/m, in good agreement with model calculations. These values are high compared to conventional cables, but become acceptable when (as here) the environment precludes the use of continuous conductors. To understand this behaviour, we present arguments for the fundamental performance limitations of these cables.« less

  10. The GEOS-20 m Cable Boom Mechanism

    NASA Technical Reports Server (NTRS)

    Schmidt, G. K.; Suttner, K.

    1977-01-01

    The GEOS Cable Boom Mechanism which allows the controlled deployment of a 20 m long cable in a centrifugal force field is described. In launch configuration the flat cable is reeled on a 240 mm diameter drum. The electrical connection between the rotating drum and the stationary housing is accomplished via a flexlead positioned inside the drum. Active motion control of this drum is achieved by a self locking worm gear, driven by a stepper motor. The deployment length of the cable is monitored by an optical length indicator, sensing black bars engraved on the cable surface.

  11. 7 CFR 1755.507 - Aerial cable services.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ....5 kilogram/meter (kg/m)] except when equivalent combinations of greater span lengths with cable... horizontal runs, cable clamps shall be placed not more than 16 in. (400 mm) apart for cable diameters equal...

  12. Dynamic Termination On Radiating Coaxial Cable

    NASA Technical Reports Server (NTRS)

    Lombardi, Robert; Stern, Jon; Rassweiler, George

    1993-01-01

    Radiation pattern dithered to reduce adverse effect of nulls. In improved system for radio communication between base station and portable units within building, tunnel, ship, or other large structure, radiating or "leaky" coaxial cable serves as base-station antenna, and radiation pattern of cable dithered by dithering impedance of termination at end of cable remote from base station.

  13. A proposed adjustable RF cable connector

    NASA Technical Reports Server (NTRS)

    Stringer, E. J.; Doyle, J. D.

    1973-01-01

    In system that requires negligible loss, it may be necessary to adjust cable length to exact multiple of transmitted wavelength. Adjustable cable connector saves time and cost by eliminating need to add to or cut from cable. Device was especially designed for use with high frequencies. For particular application, connector of suitable dimensions should be used.

  14. Development of external cooling cryo-resistive cable systems. Part 2: Insulation characteristics on 66 kV rated cryo-resistive testing cable

    NASA Astrophysics Data System (ADS)

    Ishihara, Kaoru; Akita, Shige; Suzuki, Hiroshi; Ogata, Junichi; Nemoto, Minoru

    1987-08-01

    Cryo-resistive cable system was tested to demonstrate dielectric characteristics. Dielectric characteristics of 66kV cryo-resistive cable at the start of immersion cooling in the liquid nitrogen were 2.25 specific dielectric constant and 0.18 percent dielectric loss which was less than 0.4 percent , the aimed value. Electrostatic capacity and dielectric loss tangent of dielectric characteristics under the applied voltage did not depend on the voltage and the dielectric loss was less than 0.4 percent through the temperature range from -170 to -190C. These values fulfilled the specifications on 275kV class cryo-resistive cable design. The tested cable passed the cable test on 66kV oil-filled cable (ac 90kV, 10 min), but broken down at ac 110kV on the way to endurance testing voltage 130kV. The breakdown occurred due to the mechanical damage of cable insulator by bending and thermal contraction of the cable. It is necessary from these facts to develop flexible cable terminal and joint which can absorb the contraction to realize 275kV cryo-resistive cable. (19 figs, 7 tabs, 15 refs).

  15. Applications of FRP-OFBG sensors on bridge cables

    NASA Astrophysics Data System (ADS)

    Zhou, Zhi; Zhang, Zhichun; Deng, Nianchun; Zhao, Xuefeng; Li, Dongsheng; Wang, Chuang; Ou, Jinping

    2005-05-01

    It is still a practical problem how to effectively install FBG sensors on bridge cabes. In this paper, a simple and effective solution is introduced to develop smart bridge cables using FRP-OFBG bars developed in HIT (Harbin Institute of Technology). Here, the FRP-OFBG bar acts as one component of the cable and shows force resistance and well-protected sensors in service. The installation techniques and the sensing properties of FBGs in three kinds of cables, FRP cables, common steel-wire cable and extruded-anchor cable, are introduced and tested under dead load. Moreover, the preliminary introduction of a practical field application based on this solution has been also given. The experimental results show that the deformability of FRP-OFBG bars in the smart cables can reach the terminal and show wonderful accuracy, which shows that such kind of smart cable is practical in field application.

  16. NEMA wire and cable standards development programs

    NASA Astrophysics Data System (ADS)

    Baird, Robert W.

    1994-01-01

    The National Electrical Manufacturers Association (NEMA) is the nation's largest trade association for manufacturers of electrical equipment. Its member companies produce components, end-use equipment and systems for the generation, transmission, distribution, control and use of electricity. The wire and cable division is presented in 6 sections: building wire and cable, fabricated conductors, flexible cords, high performance wire and cable, magnet wire, and power and control cable. Participating companies are listed.

  17. Cables.

    PubMed

    Cushing, M

    1994-01-01

    If you want to control your own computer installation, get the satisfaction of doing your own maintenance, and compensate for an inept or uninformed vendor, the information in this article will help you achieve these ends. Good luck and good cabling!

  18. Real-time, T-ray imaging using a sub-terahertz gyrotron

    NASA Astrophysics Data System (ADS)

    Han, Seong-Tae; Torrezan, Antonio C.; Sirigiri, Jagadishwar R.; Shapiro, Michael A.; Temkin, Richard J.

    2012-06-01

    We demonstrated real-time, active, T-ray imaging using a 0.46 THz gyrotron capable of producing 16 W in continuous wave operation and a pyroelectric array camera with 124-by-124 pixels. An expanded Gaussian beam from the gyrotron was used to maintain the power density above the detection level of the pyroelectric array over the area of the irradiated object. Real-time imaging at a video rate of 48 Hz was achieved through the use of the built-in chopper of the camera. Potential applications include fast scanning for security purposes and for quality control of dry or frozen foods.

  19. Incorrect electrode cable connection during electrocardiographic recording.

    PubMed

    Batchvarov, Velislav N; Malik, Marek; Camm, A John

    2007-11-01

    Incorrect electrode cable connections during electrocardiographic (ECG) recording can simulate rhythm or conduction disturbance, myocardial ischaemia and infarction, as well as other clinically important abnormalities. When only precordial or only limb cables, excluding the neutral cable, have been interchanged the waveforms in the different leads are re-arranged, inverted, or unchanged, whereas the duration of intervals is not changed. The mistake can be recognized by the presence of unusual P-QRS patterns (e.g. negative P-QRS in lead I or II, positive in lead AVR, P-QRS complexes of opposite direction in leads I and V6, etc.), change in the P-QRS axis, or abnormal precordial QRS-T wave progression. Interchange of limb cables with the neutral cable distorts Wilson's terminal and the morphology of all precordial and unipolar limb leads. The telltale sign of the mistake is the presence of (almost) a flat line in lead I, II or III. Interchange of even one of the limb cables, except for the neutral cable, with a precordial cable distorts the morphology of most leads and leaves not more than one lead (I, II, or III) unchanged. Computerized algorithms for detection of lead misplacement, such as those based on artificial neural networks, or on correlation between original and reconstructed leads, have been developed.

  20. Your Personal Genie in the Cable.

    ERIC Educational Resources Information Center

    Schlafly, Hubert J.

    The technology necessary for the use of cable television (TV) has been invented; it simply must be put to use. By the 1970's, cable TV should be commonplace in this country. Its rapid growth was caused in part by its appearance at a time of explosive expansion of related technologies like data theory and computer design. The coaxial cable system…

  1. Tool for cutting insulation from electrical cables

    DOEpatents

    Harless, Charles E.; Taylor, Ward G.

    1978-01-01

    This invention is an efficient hand tool for precisely slitting the sheath of insulation on an electrical cable--e.g., a cable two inches in diameter--in a manner facilitating subsequent peeling or stripping of the insulation. The tool includes a rigid frame which is slidably fitted on an end section of the cable. The frame carries a rigidly affixed handle and an opposed, elongated blade-and-handle assembly. The blade-and-handle assembly is pivotally supported by a bracket which is slidably mounted on the frame for movement toward and away from the cable, thus providing an adjustment for the depth of cut. The blade-and-handle assembly is mountable to the bracket in two pivotable positions. With the assembly mounted in the first position, the tool is turned about the cable to slit the insulation circumferentially. With the assembly mounted in the second position, the tool is drawn along the cable to slit the insulation axially. When cut both circumferentially and axially, the insulation can easily be peeled from the cable.

  2. 30 CFR 75.600 - Trailing cables; flame resistance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Trailing cables; flame resistance. 75.600... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Trailing Cables § 75.600 Trailing cables; flame resistance. [Statutory Provisions] Trailing cables used in coal mines shall meet the...

  3. 30 CFR 75.606 - Protection of trailing cables.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Protection of trailing cables. 75.606 Section... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Trailing Cables § 75.606 Protection of trailing cables. [Statutory Provisions] Trailing cables shall be adequately protected to prevent damage by...

  4. Repairing Damaged Power-Cable Insulation

    NASA Technical Reports Server (NTRS)

    Baker, G. E.

    1984-01-01

    Simple method saves time, money, and material. In new method cable remains in place while new insulation is applied to damaged portion. Method results in new terminations with safety factor equal to that of any portion of cable.

  5. Rotatable electric cable connecting system

    NASA Technical Reports Server (NTRS)

    Manges, D. R. (Inventor)

    1985-01-01

    A cable reel assembly is described which is particularly adapted for, but not limited to, a system for providing electrical connection of power and data signals between an orbiter vehicle, such as a space shuttle, and a recovered satellite. The assembly is comprised of two mutually opposing ring type structures having 180 deg relative rotation with one of the structures being held in fixed position while the other structure is rotatable. Motor controlled berthing latches and umbilical cable connectors for the satellite are located on the rim of the rotatable ring structure. The electrical cable assembly is fed in two sections from the orbiter vehicle into the outer rim portion of the fixed ring structure where they are directed inwardly and attached to two concentrically coiled metal bands whose respective ends are secured to inner and outer post members of circular sets of guide pins located on opposing circular plate members, one rotatable and one fixed. The cable sections are fed out as three output cable sections through openings in the central portion of the circular plate of the rotatable ring structure where they are directed to the latches and connectors located on its rim.

  6. 76 FR 32866 - Cable Landing Licenses; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-07

    ... FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 1 [DA 11-668] Cable Landing Licenses; Correction... Systems Agency and affects applicants requesting streamlined processing of cable landing license... paragraph (j) to read as follows: Sec. 1.767 Cable landing licenses. * * * * * (j) Applications for...

  7. Design of anti-theft/cable cut real time alert system for copper cable using microcontroller and GSM technology

    NASA Astrophysics Data System (ADS)

    Lim, E. K.; Norizan, M. N.; Mohamad, I. S.; Yasin, M. N. M.; Murad, S. A. Z.; Baharum, N. A.; Jamalullail, N.

    2017-09-01

    This paper presents the design of anti-theft/cable cut real time alert system using microcontroller and GSM technology. The detection part is using the electrical circuit wire connection in detecting the voltage drop of the cable inside the microcontroller digital input port. The GSM wireless modem is used to send the location of cable cut directly to the authority mobile phone. Microcontroller SK40C with Microchip PIC16F887 is used as a controller to control the wireless modem and also the detection device. The device is able to detect and display the location of the cable cut on the LCD display besides of and sending out the location of the cable break to the authority mobile phone wirelessly via SMS.

  8. 30 CFR 75.826 - High-voltage trailing cables.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage trailing cables. 75.826 Section 75...-Voltage Longwalls § 75.826 High-voltage trailing cables. High-voltage trailing cables must: (a) Meet existing trailing cable requirements and the approval requirements of the high-voltage continuous mining...

  9. 30 CFR 77.604 - Protection of trailing cables.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Protection of trailing cables. 77.604 Section 77.604 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... MINES Trailing Cables § 77.604 Protection of trailing cables. Trailing cables shall be adequately...

  10. 47 CFR 76.403 - Cable television system reports.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Cable television system reports. 76.403 Section 76.403 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Forms and Reports § 76.403 Cable television system reports. The operator of every operational cable...

  11. 47 CFR 76.403 - Cable television system reports.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Cable television system reports. 76.403 Section 76.403 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Forms and Reports § 76.403 Cable television system reports. The operator of every operational cable...

  12. Multiconductor Short/Open Cable Tester

    NASA Technical Reports Server (NTRS)

    Eichenberg, Dennis

    1994-01-01

    Frequent or regular testing of multiconductor cables terminated in multipin conductors tedious, if not impossible, task. This inexpensive circuit simplifies open/short testing and is amenable to automation. In operation, pair of connectors selected to match pair of connectors installed on each of cables to be tested. As many connectors accommodated as required, and each can have as many conductors as required. Testing technique implemented with this circuit automated easily with electronic controls and computer interface. Printout provides status of each conductor in cable, indicating which, if any, of conductors has open or short circuit.

  13. Counter-balanced, multiple cable construction crane

    NASA Astrophysics Data System (ADS)

    Mikulas, Martin M., Jr.; Yang, Li-Farn

    1991-11-01

    The invention is a counter-balanced, multiple cable construction crane. The apparatus for hoisting payloads comprises a crane having a lifting means, the lifting means comprising an end effector means and three suspension means or cables. One end of each cable attaches to a different winding means located on the lifting means, and the other end of each cable attaches to a different point on the end effector, such that the three cables have a theoretical point of convergence with this point corresponding to the center of mass of the payload. Three controls command rotation of the winding means to a predetermined position. Accordingly, the crane provides precise and autonomous positioning of the payload without human guidance. The crane further comprises a counter-balancing means. Two controls position the counter-balancing means to offset the overturning moment which arises during the lifting of heavy payloads.

  14. Counter-balanced, multiple cable construction crane

    NASA Astrophysics Data System (ADS)

    Mikulas, Martin M., Jr.; Yang, Li-Farn

    1993-10-01

    The invention is a counter-balanced, multiple cable construction crane. The apparatus for hoisting payloads comprises a crane having a lifting means, the lifting means comprising an end effector means and three suspension means or cables. One end of each cable attaches to a different winding means located on the lifting means, and the other end of each cable attaches to a different point on the end effector, such that the three cables have a theoretical point of convergence with this point corresponding to the center of mass of the payload. Three controls command rotation of the winding means to a predetermined position. Accordingly, the crane provides precise and autonomous positioning of the payload without human guidance. The crane further comprises a counter-balancing means. Two controls position the counter-balancing means to offset the overturning moment which arises during the lifting of heavy payloads.

  15. Counter-balanced, multiple cable construction crane

    NASA Technical Reports Server (NTRS)

    Mikulas, Martin M., Jr. (Inventor); Yang, Li-Farn (Inventor)

    1993-01-01

    The invention is a counter-balanced, multiple cable construction crane. The apparatus for hoisting payloads comprises a crane having a lifting means, the lifting means comprising an end effector means and three suspension means or cables. One end of each cable attaches to a different winding means located on the lifting means, and the other end of each cable attaches to a different point on the end effector, such that the three cables have a theoretical point of convergence with this point corresponding to the center of mass of the payload. Three controls command rotation of the winding means to a predetermined position. Accordingly, the crane provides precise and autonomous positioning of the payload without human guidance. The crane further comprises a counter-balancing means. Two controls position the counter-balancing means to offset the overturning moment which arises during the lifting of heavy payloads.

  16. Burning Characteristics and Flammability of PVC Cables in Groups

    NASA Technical Reports Server (NTRS)

    Mikado, T.; Akita, K.

    1988-01-01

    Because burning cables represent a danger of increasing secondary damage it is of utmost importance for disaster prevention to correctly evaluate the combustion characteristics of cable. However, in many cases cable is laid out in bundles complicating the combustion characteristics. A situation has developed where group cable characteristics are not completely understood. A new method is developed for testing the combustion of high polymer type cable and earlier reports gave comparative combustion measurement results. It was learned that there is considerable difference between the combustion characteristics of the grouped cables and those of single cables. This study is supplemental research concerning the special behavior of group PVC cables, throwing some light on their combustion characteristics.

  17. TANKS 18 AND 19-F EQUIPMENT GROUT FILL MATERIAL EVALUATION AND RECOMMENDATIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stefanko, D.; Langton, C.

    The United States Department of Energy (US DOE) intends to remove Tanks 18-F and 19-F at the Savannah River Site (SRS) from service. The high-level waste (HLW) tanks have been isolated from the F-area Tank Farm (FTF) facilities and will be filled with cementitious grout for the purpose of: (1) physically stabilizing the empty volumes in the tanks, (2) limiting/eliminating vertical pathways from the surface to residual waste on the bottom of the tanks, (3) providing an intruder barrier, and (4) providing an alkaline, chemical reducing environment within the closure boundary to limit solubility of residual radionuclides. Bulk waste andmore » heel waste removal equipment will remain in Tanks 18-F and 19-F when the tanks are closed. This equipment includes: mixer pumps, transfer pumps, transfer jets, equipment support masts, sampling masts and dip tube assemblies. The current Tank 18-F and 19-F closure strategy is to grout the internal void spaces in this equipment to eliminate fast vertical pathways and slow water infiltration to the residual material on the tank floor. This report documents the results of laboratory testing performed to identify a grout formulation for filling the abandoned equipment in Tanks 18-F and 19-F. The objective of this work was to formulate a flowable grout for filling internal voids of equipment that will remain in Tanks 18-F and 19-F during the final closures. This work was requested by V. A. Chander, Tank Farm Closure Engineering, in HLW-TTR-2011-008. The scope for this task is provided in the Task Technical and Quality Assurance Plan (TTQAP), SRNL-RP-2011-00587. The specific objectives of this task were to: (1) Prepare and evaluate the SRR cooling coil grout identified in WSRC-STI-2008-00298 per the TTR for this work. The cooling coil grout is a mixture of BASF MasterFlow{reg_sign} 816 cable grout (67.67 wt. %), Grade 100 ground granulated blast furnace slag (7.52 wt. %) and water (24.81 wt. %); (2) Identify equipment grout placement

  18. 30 CFR 77.606 - Energized trailing cables; handling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Energized trailing cables; handling. 77.606... COAL MINES Trailing Cables § 77.606 Energized trailing cables; handling. Energized medium- and high-voltage trailing cables shall be handled only by persons wearing protective rubber gloves (see § 77.606-1...

  19. 97. VIEW OF NORTH SIDE OF LANDLINE INSTRUMENTATION ROOM (106), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    97. VIEW OF NORTH SIDE OF LANDLINE INSTRUMENTATION ROOM (106), LSB (BLDG. 770). EAST ROW OF CABINETS INCLUDES, LEFT TO RIGHT: CABLE DISTRIBUTION UNITS, AUTOPILOT CHECKOUT CONTROLS, AND POWER DISTRIBUTION UNITS. NOTE OVERHEAD DUCTS FOR INSTRUMENT AIR CONDITIONING AND CABLE TRAYS ON EAST, WEST, AND SOUTH WALLS. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  20. Tray service generates more food waste in dining areas of a continuing-care retirement community.

    PubMed

    Hackes, B L; Shanklin, C W; Kim, T; Su, A Y

    1997-08-01

    To determine if the type of service system affects the amount of service food waste (SFW) generated in dining areas of a continuing-care retirement community. A waste stream analysis was conducted for 7 days to determine quantity of SFW generated in three service systems: health care tray service, health care dining room with wait-staff service, and ambulatory dining room with family-style service. Weight and volume were determined. Health care tray service and wait-staff service were provided to 70 residents in a health care unit. Family-style service was provided as an optional service for 130 residents in independent-living units. An average of 229 meals were served per day. Analysis of variance and a multiple comparison method were used to compare mean weight and volume of SFW on a per meal, per day, and per week basis. During the 7-day period, 482.8 lb, or 83 gal, of SFW was disposed of Health care tray service generated more SFW by weight for all three meals than either family-style service or wait-staff service, and it generated the greatest total volume of service waste. Residents eating in the dining room with family-style service disposed of significantly less SFW by weight at lunch and dinner than those receiving the other two service styles. Changing the style of service can affect not only quantity of solid waste generated and associated disposal costs but also food and supply costs, meal acceptability, and quantity of natural resources required. The systems approach should be used to assess the feasibility of changing service system so that all costs are considered.

  1. Scanning electron microscope/energy dispersive x ray analysis of impact residues on LDEF tray clamps

    NASA Technical Reports Server (NTRS)

    Bernhard, Ronald P.; Durin, Christian; Zolensky, Michael E.

    1992-01-01

    To better understand the nature of particulates in low-Earth orbit (LEO), and their effects on spacecraft hardware, we are analyzing residues found in impacts on the Long Duration Exposure Facility (LDEF) tray clamps. LDEF experiment trays were held in place by 6 to 8 chromic-anodized aluminum (6061-T6) clamps that were fastened to the spacecraft frame using three stainless steel hex bolts. Each clamp exposed an area of approximately 58 sq cm (4.8 cm x 12.7 cm x .45 cm, minus the bolt coverage). Some 337 out of 774 LDEF tray clamps were archived at JSC and are available through the Meteoroid & Debris Special Investigation Group (M&D SIG). Optical scanning of clamps, starting with Bay/Row A01 and working toward H25, is being conducted at JSC to locate and document impacts as small as 40 microns. These impacts are then inspected by Scanning Electron Microscopy/Energy Dispersive X-ray Analysis (SEM/EDXA) to select those features which contain appreciable impact residue material. Based upon the composition of projectile remnants, and using criteria developed at JSC, we have made a preliminary discrimination between micrometeoroid and space debris residue-containing impact features. Presently, 13 impacts containing significant amounts of unmelted and semi-melted micrometeoritic residues were forwarded to Centre National d'Etudes Spatiales (CNES) in France. At the CNES facilities, the upgraded impacts were analyzed using a JEOL T330A SEM equipped with a NORAN Instruments, Voyager X-ray Analyzer. All residues were quantitatively characterized by composition (including oxygen and carbon) to help understand interplanetary dust as possibly being derived from comets and asteroids.

  2. Manufacturing Superconducting Cables

    NASA Technical Reports Server (NTRS)

    England, Christopher

    1996-01-01

    Process proposed for manufacture of cables containing ceramic high-temperature-superconductor YBa(2)Cu(3)O(7-a). For protection, superconducting ceramic encapsulated before activation. Cables carry electrical current with little or no loss of power when cooled to or below temperatures of about minus 200 degrees C. Process accommodates brittle nature of YBa(2)Cu(3)O(7-a) and economical and readily controllable. Also flexible in sense modified to accommodate variety of precursor materials to be processed into YBa(2)Cu(3)O(7-a).

  3. Helical grip for the cable cars of San Francisco

    NASA Technical Reports Server (NTRS)

    Peyran, R. J.

    1979-01-01

    A helical cable car grip to minimize high maintenance costs of San Francisco's cable car operation is presented. The grip establishes a rolling contact between the cable and grip to reduce sliding friction and associated cable wear. The design, development, and testing of the helical cable car grip are described.

  4. Design considerations for high-power VHF radar transceivers: Phase matching long coaxial cables using a cable radar

    NASA Technical Reports Server (NTRS)

    Johnson, P. E.; Ecklund, W. L.

    1983-01-01

    The Poker Flat 49.92-MHz MST radar uses 64 phase-controlled transmitters in individual shelters distributed throughout the antenna array. Phase control is accomplished by sampling the transmitted pulse at the directional coupler of each transmitter and sending the sample pulse back to a phase-control unit. This method requires phase matching 64 long (256 meter) coaxial cables (RG-213) to within several electrical degrees. Tests with a time domain reflectometer showed that attenuation of high frequency components in the long RG-213 cable rounded the leading edge of the reflected pulse so that the cables could only be measured to within 50 cm (about 45 deg at 49.92 MHz). Another measurement technique using a vector voltmeter to compare forward and reflected phase required a directional coupler with unattainable directivity. Several other techniques were also found lacking, primarily because of loss in the long RG-213 cables. At this point it was realized that what was needed was a simple version of the phase-coherent clear-air radar, i.e., a cable radar. The design and operation of this cable are described.

  5. 47 CFR 32.2424 - Submarine & deep sea cable.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 2 2011-10-01 2011-10-01 false Submarine & deep sea cable. 32.2424 Section 32... Submarine & deep sea cable. (a) This account shall include the original cost of submarine cable and deep sea... defined below, are to be maintained for nonmetallic submarine and deep sea cable and metallic submarine...

  6. 47 CFR 32.2424 - Submarine & deep sea cable.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 2 2014-10-01 2014-10-01 false Submarine & deep sea cable. 32.2424 Section 32... Submarine & deep sea cable. (a) This account shall include the original cost of submarine cable and deep sea... defined below, are to be maintained for nonmetallic submarine and deep sea cable and metallic submarine...

  7. 47 CFR 32.2424 - Submarine & deep sea cable.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Submarine & deep sea cable. 32.2424 Section 32... Submarine & deep sea cable. (a) This account shall include the original cost of submarine cable and deep sea... defined below, are to be maintained for nonmetallic submarine and deep sea cable and metallic submarine...

  8. 47 CFR 32.2424 - Submarine & deep sea cable.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 2 2013-10-01 2013-10-01 false Submarine & deep sea cable. 32.2424 Section 32... Submarine & deep sea cable. (a) This account shall include the original cost of submarine cable and deep sea... defined below, are to be maintained for nonmetallic submarine and deep sea cable and metallic submarine...

  9. 47 CFR 32.2424 - Submarine & deep sea cable.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 2 2012-10-01 2012-10-01 false Submarine & deep sea cable. 32.2424 Section 32... Submarine & deep sea cable. (a) This account shall include the original cost of submarine cable and deep sea... defined below, are to be maintained for nonmetallic submarine and deep sea cable and metallic submarine...

  10. Wire in the Cable-Driven System of Surgical Robot

    NASA Astrophysics Data System (ADS)

    Wang, X. F.; Lv, N.; Mu, H. Z.; Xue, L. J.

    2017-07-01

    During the evolution of the surgical robot, cable plays an important role. It translates motion and force precisely from surgeon’s hand to the tool’s tips. In the paper, the vertical wires, the composition of cable, are mathematically modeled from a geometric point of view. The cable structure and tension are analyzed according to the characteristics of wire screw twist. The structural equations of the wires in different positions are derived for both non-bent cable and bent cable, respectively. The bending moment formula of bent cable is also obtained. This will help researchers find suitable cable and design more matched pulley.

  11. Non-Intrusive Impedance-Based Cable Tester

    NASA Technical Reports Server (NTRS)

    Medelius, Pedro J. (Inventor); Simpson, Howard J. (Inventor)

    1999-01-01

    A non-intrusive electrical cable tester determines the nature and location of a discontinuity in a cable through application of an oscillating signal to one end of the cable. The frequency of the oscillating signal is varied in increments until a minimum, close to zero voltage is measured at a signal injection point which is indicative of a minimum impedance at that point. The frequency of the test signal at which the minimum impedance occurs is then employed to determine the distance to the discontinuity by employing a formula which relates this distance to the signal frequency and the velocity factor of the cable. A numerically controlled oscillator is provided to generate the oscillating signal, and a microcontroller automatically controls operation of the cable tester to make the desired measurements and display the results. The device is contained in a portable housing which may be hand held to facilitate convenient use of the device in difficult to access locations.

  12. Wireline tool cable head overload apparatus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roessler, D.E.

    1990-05-29

    This patent describes a cable head adapted to support a sonde in a well borehole. It comprises: an upper end assembly adapted for connection with a cable extending into a well borehole; a lower end assembly adapted for connection to a sonde to be supported by the cable in the well borehole; yieldable means joining the upper and lower assemblies together in a fixed but yieldable relationship wherein a controllable and variable load is imparted to the cable there above during movement and variations in load on the cable are maintained within specified limits; the yieldable means further including deadmore » weight adjustable means notwithstanding variations in the dead weight of the load, and the yieldable means includes resilient means permitting movements within a desired range dependent on the adjustment thereof and bracketing a selected relative position of the upper and lower end assemblies; and an electrical contact.« less

  13. An Internal Coaxil Cable Seal System

    DOEpatents

    Hall, David R.; Hall, Jr., H. Tracy; Pixton, David; Dahlgren, Scott; Sneddon, Cameron; Briscoe, Michael; Fox, Joe

    2004-12-23

    The invention is a seal system for a coaxial cable more specifically an internal seal system placed within the coaxial cable and its constituent components. A series of seal stacks including flexible rigid rings and elastomeric rings are placed on load bearing members within the coaxial cable. The current invention is adapted to seal the annular space between the coaxial cable and an electrical contact passing there through. The coaxial cable is disposed within drilling components to transmit electrical signals between drilling components within a drill string. During oil and gas exploration, a drill string can see a range of pressures and temperatures thus resulting in multiple combinations of temperature and pressure and increasing the difficulty of creating a robust seal for all combinations. The seal system can be used in a plurality of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars.

  14. 30 CFR 57.4057 - Underground trailing cables.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and Control § 57.4057 Underground trailing cables. Underground trailing cables shall be accepted or... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Underground trailing cables. 57.4057 Section 57.4057 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL...

  15. 30 CFR 57.4057 - Underground trailing cables.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... and Control § 57.4057 Underground trailing cables. Underground trailing cables shall be accepted or... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Underground trailing cables. 57.4057 Section 57.4057 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL...

  16. 30 CFR 57.4057 - Underground trailing cables.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and Control § 57.4057 Underground trailing cables. Underground trailing cables shall be accepted or... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Underground trailing cables. 57.4057 Section 57.4057 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL...

  17. 30 CFR 57.4057 - Underground trailing cables.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and Control § 57.4057 Underground trailing cables. Underground trailing cables shall be accepted or... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Underground trailing cables. 57.4057 Section 57.4057 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL...

  18. Heart catheter cable and connector

    NASA Technical Reports Server (NTRS)

    Harrison, D. R.; Cota, F. L.; Sandler, H.

    1972-01-01

    Ultraminiature catheter cables that are stiff enough for intravenous insertion yet flexible at the tip, sterilizable, and economical are fabricated entirely from commercially available parts. Assembly includes air passageway for reference pressures and coaxial cable for transmission of signals from the tip of catheter.

  19. High-temperature flat-conductor cable

    NASA Technical Reports Server (NTRS)

    Rigling, W. S.

    1976-01-01

    Temperature limit of 25-conductor signal cable and 3-conductor power cable, fabricated using woven and roll laminated technique, increased from 200 C to 350 C when polyimide/fluorinated ethylene propylene or polytetrafluoroethylene insulation films and fluorinated ethylene propylene as adhesive medium is applied.

  20. Cable for prospecting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lebouc, L.; Marmignon, J.

    1983-03-29

    A cable for prospecting, said cable including a core of conductor wires surrounded by insulating material and by armour formed by at least one layer of helically wound steel wires. It includes, from its center to its periphery, inside the armour, an axial monofilament made of a polymer that withstands high temperatures, said monofilament forming the insulation of an inner conductor, an outer conductor and a sheath made of a thermoplastic substance that withstands high temperatures, said inner conductor serving a different electrical function than said core of conductor wires.

  1. Cable-catenary large antenna concept

    NASA Technical Reports Server (NTRS)

    Akle, W.

    1985-01-01

    Deployable to very large diameters (over 1000 ft), while still remaining compatible with a complete satellite system launch by STS, the cable-catenary antenna comprises: 8 radial deployable boom masts; a deployable hub and feed support center mast; balanced front and back, radial and circumferential catenary cabling for highly accurate (mm) surface control; no interfering cabling in the antenna field; and an RF reflecting mesh supported on the front catenaries. Illustrations show the antenna-satellite system deployed and stowed configurations; the antenna deployment sequence; the design analysis logic; the sizing analysis output, and typical parametric design data.

  2. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, E.B.; Muller, A.C.

    1983-07-15

    The present invention is a cable which, although constructed from inexpensive polyolefin tapes and using typical impregnating oils, furnishes high voltage capability up to 765 kV, and has such excellent dielectric characteristics and heat transfer properties that it is capable of operation at capacities equal to or higher than presently available cables at a given voltage. This is accomplished by using polyethylene, polybutene or polypropylene insulating tape which has been specially processed to attain properties which are not generally found in these materials, but are required for their use in impregnated electrical cables. Chief among these properties is compatibility with impregnating oil.

  3. 47 CFR 76.111 - Cable sports blackout.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Cable sports blackout. 76.111 Section 76.111... CABLE TELEVISION SERVICE Network Non-duplication Protection, Syndicated Exclusivity and Sports Blackout § 76.111 Cable sports blackout. (a) No community unit located in whole or in part within the specified...

  4. 47 CFR 76.111 - Cable sports blackout.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 4 2013-10-01 2013-10-01 false Cable sports blackout. 76.111 Section 76.111... CABLE TELEVISION SERVICE Network Non-duplication Protection, Syndicated Exclusivity and Sports Blackout § 76.111 Cable sports blackout. (a) No community unit located in whole or in part within the specified...

  5. 47 CFR 76.111 - Cable sports blackout.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Cable sports blackout. 76.111 Section 76.111... CABLE TELEVISION SERVICE Network Non-duplication Protection, Syndicated Exclusivity and Sports Blackout § 76.111 Cable sports blackout. (a) No community unit located in whole or in part within the specified...

  6. 47 CFR 32.2426 - Intrabuilding network cable.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Intrabuilding network cable. 32.2426 Section 32... Intrabuilding network cable. (a) This account shall include the original cost of cables and wires located on the company's side of the demarcation point or standard network interface inside subscribers' buildings or...

  7. 47 CFR 32.2426 - Intrabuilding network cable.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 2 2011-10-01 2011-10-01 false Intrabuilding network cable. 32.2426 Section 32... Intrabuilding network cable. (a) This account shall include the original cost of cables and wires located on the company's side of the demarcation point or standard network interface inside subscribers' buildings or...

  8. 47 CFR 15.213 - Cable locating equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Cable locating equipment. 15.213 Section 15.213 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Intentional Radiators § 15.213 Cable locating equipment. An intentional radiator used as cable locating equipment, as defined in § 15.3...

  9. 47 CFR 76.111 - Cable sports blackout.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Cable sports blackout. 76.111 Section 76.111... CABLE TELEVISION SERVICE Network Non-duplication Protection, Syndicated Exclusivity and Sports Blackout § 76.111 Cable sports blackout. (a) No community unit located in whole or in part within the specified...

  10. 47 CFR 76.111 - Cable sports blackout.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Cable sports blackout. 76.111 Section 76.111... CABLE TELEVISION SERVICE Network Non-duplication Protection, Syndicated Exclusivity and Sports Blackout § 76.111 Cable sports blackout. (a) No community unit located in whole or in part within the specified...

  11. Motion Law Analysis and Structural Optimization of the Ejection Device of Tray Seeder

    NASA Astrophysics Data System (ADS)

    Luo, Xin; Hu, Bin; Dong, Chunwang; Huang, Lili

    An ejection mechanism consisting four reset springs, an electromagnet and a seed disk was designed for tray seeder. The motion conditions of seeds in the seed disk were theoretical analyzed and intensity and height of seed ejection were calculated. The motions of the seeds and seed disk were multi-body dynamic simulated using Cosmos modules plug-in SolidWorks software package. The simulation results showed the consistence with the theoretical analysis.

  12. Optimal energy harvesting from vortex-induced vibrations of cables.

    PubMed

    Antoine, G O; de Langre, E; Michelin, S

    2016-11-01

    Vortex-induced vibrations (VIV) of flexible cables are an example of flow-induced vibrations that can act as energy harvesting systems by converting energy associated with the spontaneous cable motion into electricity. This work investigates the optimal positioning of the harvesting devices along the cable, using numerical simulations with a wake oscillator model to describe the unsteady flow forcing. Using classical gradient-based optimization, the optimal harvesting strategy is determined for the generic configuration of a flexible cable fixed at both ends, including the effect of flow forces and gravity on the cable's geometry. The optimal strategy is found to consist systematically in a concentration of the harvesting devices at one of the cable's ends, relying on deformation waves along the cable to carry the energy towards this harvesting site. Furthermore, we show that the performance of systems based on VIV of flexible cables is significantly more robust to flow velocity variations, in comparison with a rigid cylinder device. This results from two passive control mechanisms inherent to the cable geometry: (i) the adaptability to the flow velocity of the fundamental frequencies of cables through the flow-induced tension and (ii) the selection of successive vibration modes by the flow velocity for cables with gravity-induced tension.

  13. Optimal energy harvesting from vortex-induced vibrations of cables

    NASA Astrophysics Data System (ADS)

    Antoine, G. O.; de Langre, E.; Michelin, S.

    2016-11-01

    Vortex-induced vibrations (VIV) of flexible cables are an example of flow-induced vibrations that can act as energy harvesting systems by converting energy associated with the spontaneous cable motion into electricity. This work investigates the optimal positioning of the harvesting devices along the cable, using numerical simulations with a wake oscillator model to describe the unsteady flow forcing. Using classical gradient-based optimization, the optimal harvesting strategy is determined for the generic configuration of a flexible cable fixed at both ends, including the effect of flow forces and gravity on the cable's geometry. The optimal strategy is found to consist systematically in a concentration of the harvesting devices at one of the cable's ends, relying on deformation waves along the cable to carry the energy towards this harvesting site. Furthermore, we show that the performance of systems based on VIV of flexible cables is significantly more robust to flow velocity variations, in comparison with a rigid cylinder device. This results from two passive control mechanisms inherent to the cable geometry: (i) the adaptability to the flow velocity of the fundamental frequencies of cables through the flow-induced tension and (ii) the selection of successive vibration modes by the flow velocity for cables with gravity-induced tension.

  14. Commercialization of Medium Voltage HTS Triax TM Cable Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knoll, David

    2012-12-31

    The original project scope that was established in 2007 aimed to install a 1,700 meter (1.1 mile) medium voltage HTS Triax{TM} cable system into the utility grid in New Orleans, LA. In 2010, however, the utility partner withdrew from the project, so the 1,700 meter cable installation was cancelled and the scope of work was reduced. The work then concentrated on the specific barriers to commercialization of HTS cable technology. The modified scope included long-length HTS cable design and testing, high voltage factory test development, optimized cooling system development, and HTS cable life-cycle analysis. In 2012, Southwire again analyzed themore » market for HTS cables and deemed the near term market acceptance to be low. The scope of work was further reduced to the completion of tasks already started and to testing of the existing HTS cable system in Columbus, OH. The work completed under the project included: • Long-length cable modeling and analysis • HTS wire evaluation and testing • Cable testing for AC losses • Optimized cooling system design • Life cycle testing of the HTS cable in Columbus, OH • Project management. The 200 meter long HTS Triax{TM} cable in Columbus, OH was incorporated into the project under the initial scope changes as a test bed for life cycle testing as well as the site for an optimized HTS cable cooling system. The Columbus cable utilizes the HTS TriaxTM design, so it provided an economical tool for these of the project tasks.« less

  15. 46 CFR 129.340 - Cable and wiring.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... buildup of condensation. (b) Each cable and wire must— (1) Have stranded copper conductors with sufficient... Power Sources and Distribution Systems § 129.340 Cable and wiring. (a) If individual wires, rather than cables, are used in systems operating at a potential of greater than 50 volts, the wire and associated...

  16. 46 CFR 129.340 - Cable and wiring.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... buildup of condensation. (b) Each cable and wire must— (1) Have stranded copper conductors with sufficient... Power Sources and Distribution Systems § 129.340 Cable and wiring. (a) If individual wires, rather than cables, are used in systems operating at a potential of greater than 50 volts, the wire and associated...

  17. 46 CFR 129.340 - Cable and wiring.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... buildup of condensation. (b) Each cable and wire must— (1) Have stranded copper conductors with sufficient... Power Sources and Distribution Systems § 129.340 Cable and wiring. (a) If individual wires, rather than cables, are used in systems operating at a potential of greater than 50 volts, the wire and associated...

  18. 46 CFR 129.340 - Cable and wiring.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... buildup of condensation. (b) Each cable and wire must— (1) Have stranded copper conductors with sufficient... Power Sources and Distribution Systems § 129.340 Cable and wiring. (a) If individual wires, rather than cables, are used in systems operating at a potential of greater than 50 volts, the wire and associated...

  19. Using Cable Television for Library Data Transmission.

    ERIC Educational Resources Information Center

    Whitaker, Douglas A.

    1985-01-01

    Discusses information gained from a test of cable data circuits on a Geac bibliographic control system at the Wayne Oakland Library Federation (WOLF) (Michigan). Highlights include an introduction to cable, hardware profile, the WOLF experience, and key questions that will affect the future use of cable for data transmission. (EJS)

  20. 46 CFR 113.10-3 - Cable runs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Cable runs. 113.10-3 Section 113.10-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-3 Cable runs. Cable runs between...

  1. 46 CFR 113.10-3 - Cable runs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Cable runs. 113.10-3 Section 113.10-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-3 Cable runs. Cable runs between...

  2. 46 CFR 113.10-3 - Cable runs.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Cable runs. 113.10-3 Section 113.10-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-3 Cable runs. Cable runs between...

  3. 46 CFR 113.10-3 - Cable runs.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Cable runs. 113.10-3 Section 113.10-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-3 Cable runs. Cable runs between...

  4. 46 CFR 113.10-3 - Cable runs.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Cable runs. 113.10-3 Section 113.10-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING COMMUNICATION AND ALARM SYSTEMS AND EQUIPMENT Fire and Smoke Detecting and Alarm Systems § 113.10-3 Cable runs. Cable runs between...

  5. Coaxial cable Bragg grating assisted microwave coupler.

    PubMed

    Huang, Jie; Wei, Tao; Fan, Jun; Xiao, Hai

    2014-01-01

    This paper reports a microwave coupler based on two parallel coaxial cable Bragg gratings fabricated by drilling U-grooves across the cables at periodic distance along the cable direction. Electromagnetic field couplings between two cables were observed at discrete frequencies through both near and far ends detections. The coupling frequency and strength can be precisely controlled by varying the grating period and length. The coupling bandwidth may also be controlled through specific grating design. The device physics was also described through transfer matrix which matched well with the experimental results.

  6. Thin semi-rigid coaxial cables for cryogenics applications

    NASA Astrophysics Data System (ADS)

    Kushino, Akihiro; Kasai, Soichi

    2013-03-01

    We have developed cryogenic coaxial cables for low temperature signal readout from sensitive devices, such as transition edge sensors, superconducting tunnel junctions, and kinetic inductance detectors. In order to reduce heat penetration into cryogenic stages, low thermal conductivity metals were chosen for both center and outer electrical conductors. Various types of coaxial cables, employing stainless-steel, cupro-nickel, brass, beryllium-copper, phosphor-bronze, niobium, and niobium-titanium, were manufactured using drawing dies. Thermal and electrical properties were investigated between 1 and 8 K. Coaxial cables made of copper alloys showed thermal conductance roughly consistent with literature, meanwhile Nb coaxial cable must be affected by the drawing process and thermal conductance was lowered. Attenuation of superconducting Nb and NbTi coaxial cables were observed to be adequately small up to above 10 GHz compared to those of normal conducting coaxial cables, which are subject to the Wiedemann-Franz law. We also measured normal conducting coaxial cables with silver-plated center conductors to improve high frequency performance.

  7. External heating of electrical cables and auto-ignition investigation.

    PubMed

    Courty, L; Garo, J P

    2017-01-05

    Electric cables are now extensively used for both residential and industrial applications. During more than twenty years, multi-scale approaches have been developed to study fire behavior of such cables that represents a serious challenge. Cables are rather complicated materials because they consist of an insulated part and jacket of polymeric materials. These polymeric materials can have various chemical structures, thicknesses and additives and generally have a char-forming tendency when exposed to heat source. In this work, two test methods are used for the characterization of cable pyrolysis and flammability. The first one permits the investigation of cable pyrolysis. A description of the cable mass loss is obtained, coupling an Arrhenius expression with a 1D thermal model of cables heating. Numerical results are successfully compared with experimental data obtained for two types of cable commonly used in French nuclear power plants. The second one is devoted to ignition investigations (spontaneous or piloted) of these cables. All these basic observations, measurements and modelling efforts are of major interest for a more comprehensive fire resistance evaluation of electric cables. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. The Cable Book. Community Television for Massachusetts?

    ERIC Educational Resources Information Center

    Achtenberg, Ben

    This manual is especially designed to inform and aid community organizations in understanding cable television and planning for the future. With the exception of the chapter on Massachusetts cable legislation, most of the book should be useful to community organizations anywhere. At the beginning, the history and experience of cable television in…

  9. Causes of Cracking of Ignition Cable

    NASA Technical Reports Server (NTRS)

    Silsbee, F B

    1921-01-01

    The experiments described here show that the cracking at sharp bends, observed in the insulation of internal combustion engine high tension ignition wires after service, is due to a chemical attack upon the rubber by the ozone produced by the electric discharge that takes place at the surface of the cable. This cracking does not occur if the insulating material is not under tension, or if the cable is surrounded by some medium other than air. But it does occur even if the insulation is not subjected to electric stress, provided that the atmosphere near the cable contains ozone. The extent of this cracking varies greatly with the insulating material used. The cracking can be materially reduced by using braided cable and by avoiding sharp bends.

  10. Cable Television and the University.

    ERIC Educational Resources Information Center

    Lyman, Richard

    Universities contain powerful blocs of resistance to new educational technology, perhaps especially to television. University attitudes and structures as well as faculty ignorance, apathy, and resistance affect the development of cable television. No one seems to speak with great confidence and precision about the educational potential of cable.…

  11. Protected, high-temperature connecting cable

    NASA Technical Reports Server (NTRS)

    Engdahl, R. E.

    1967-01-01

    Ceramic insulated, swaged stainless steel, sheathed, protective atmosphere cable admits electrical leads into an 1800 deg F air-environment test chamber. The cable has some bending capability and provides for nine niobium alloy conductors. An argon purge during the TIG weld closure protects internal wires from oxidation and embrittlement.

  12. Light Water Reactor Sustainability Program: Evaluation of Localized Cable Test Methods for Nuclear Power Plant Cable Aging Management Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glass, Samuel W.; Fifield, Leonard S.; Hartman, Trenton S.

    This Pacific Northwest National Laboratory (PNNL) milestone report describes progress to date on the investigation of nondestructive test (NDE) methods focusing particularly on local measurements that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As NPPs consider applying for second, or subsequent, license renewal (SLR) to extend their operating period from 60 years to 80 years, it important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs (AMPs) to assure continuedmore » safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program is directed toward the more demanding challenge of assuring the cable function under accident or DBE. Most utilities already have a program associated with their first life extension from 40 to 60 years. Regrettably, there is neither a clear guideline nor a single NDE that can assure cable function and integrity for all cables. Thankfully, however, practical implementation of a broad range of tests allows utilities to develop a practical program that assures cable function to a high degree. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB is a destructive test so the test programs must apply an array of other NDE tests to assure or infer the overall set of cable’s system integrity. These cable NDE programs vary in rigor and methodology. As the industry gains experience with the efficacy of these programs, it is expected that implementation practice will converge to a more common approach. This report addresses the range of local NDE cable tests

  13. The use of sublaminar cables to replace Luque wires.

    PubMed

    Songer, M N; Spencer, D L; Meyer, P R; Jayaraman, G

    1991-08-01

    Sublaminar wires have been used in conjunction with posterior instrumentation to stabilize the spine. Sublaminar wiring has fallen into disfavor because of an increase in neurologic complications with the Luque technique as well as wire breakage, dural tears, and difficulty of removal. A cable system consisting of two 49-stranded stainless steel cables connected to one malleable leader was designed to overcome these shortcomings. Biomechanical testing revealed that the maximum yield strength of a single stainless steel cable loop was 2.85-2.94 times greater than a double 0.05-in. stainless steel wire loop. The fatigue tests demonstrated that the stainless steel cables required 6-22 times more cycles to failure than the stainless steel wire. Many of the titanium cables failed immediately under higher loads (0-100 lb) because of slipping of the crimp. The preliminary clinical results after a mean of 19 months of follow-up of 245 cables are encouraging. There has been no breakage or loosening of the cables and no complications associated with the use of the cables. The stainless steel cables are very strong, but more important, the cable flexibility prevents repeated contusions to the spinal cord during insertion of the rods and tightening of wires. The cable conforms to the undersurface of the lamina. This may lead to a decrease in neurologic complications.

  14. 30 CFR 57.12088 - Splicing trailing cables.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Splicing trailing cables. 57.12088 Section 57... Underground Only § 57.12088 Splicing trailing cables. No splice, except a vulcanized splice or its equivalent, shall be made in a trailing cable within 25 feet of the machine unless the machine is equipped with a...

  15. Cable Feedthrough Between Liquid Oxygen And Ambient

    NASA Technical Reports Server (NTRS)

    Myers, Don A.

    1992-01-01

    Encapsulant and back pressure provide double protection. Cable-feedthrough tube between ambient air and interior of vessel containing liquid oxygen protects external instrumentation and cable from oxygen. Cable in tube surrounded by potting compound. Provides flow of gaseous nitrogen to dilute oxidant and makes it harmless in case of leakage through crack in potting compound.

  16. Shape adjustment optimization and experiment of cable-membrane reflectors

    NASA Astrophysics Data System (ADS)

    Du, Jingli; Gu, Yongzhen; Bao, Hong; Wang, Congsi; Chen, Xiaofeng

    2018-05-01

    Cable-membrane structures are widely employed for large space reflectors due to their lightweight, compact and easy package. In these structures, membranes are attached to cable net, serving as reflectors themselves or as supporting structures for other reflective surface. The cable length and membrane shape have to be carefully designed and fabricated to guarantee the desired reflector surface shape. However, due to inevitable error in cable length and membrane shape during the manufacture and assembly of cable-membrane reflectors, some cables have to be designed to be capable of length adjustment. By carefully adjusting the length of these cables, the degeneration in reflector shape precision due to this inevitable error can be effectively reduced. In the paper a shape adjustment algorithm for cable-membrane reflectors is proposed. Meanwhile, model updating is employed during shape adjustment to decrease the discrepancy of the numerical model with respect to the actual reflector. This discrepancy has to be considered because during attaching membranes to cable net, the accuracy of the membrane shape is hard to guarantee. Numerical examples and experimental results demonstrate the proposed method.

  17. Superconducting cable connections and methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    van der Laan, Daniel Cornelis

    2017-09-05

    Superconducting cable connector structures include a terminal body (or other structure) onto which the tapes from the superconducting cable extend. The terminal body (or other structure) has a diameter that is sufficiently larger than the diameter of the former of the superconducting cable, so that the tapes spread out over the outer surface of the terminal body. As a result, gaps are formed between tapes on the terminal body (or other structure). Those gaps are filled with solder (or other suitable flowable conductive material), to provide a current path of relatively high conductivity in the radial direction. Other connector structuresmore » omit the terminal body.« less

  18. 33 CFR 157.15 - Slop tanks in tank vessels.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Slop tanks in tank vessels. 157... (CONTINUED) POLLUTION RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Design, Equipment, and Installation § 157.15 Slop tanks in tank vessels. (a) Number. A...

  19. 33 CFR 157.15 - Slop tanks in tank vessels.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Slop tanks in tank vessels. 157... (CONTINUED) POLLUTION RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Design, Equipment, and Installation § 157.15 Slop tanks in tank vessels. (a) Number. A...

  20. 33 CFR 157.15 - Slop tanks in tank vessels.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Slop tanks in tank vessels. 157... (CONTINUED) POLLUTION RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Design, Equipment, and Installation § 157.15 Slop tanks in tank vessels. (a) Number. A...

  1. 33 CFR 157.15 - Slop tanks in tank vessels.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Slop tanks in tank vessels. 157... (CONTINUED) POLLUTION RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Design, Equipment, and Installation § 157.15 Slop tanks in tank vessels. (a) Number. A...

  2. Data Base On Cables And Connectors

    NASA Technical Reports Server (NTRS)

    Bowen, Arlen R.; Oliver, John D.

    1995-01-01

    Report describes Connector Adapter Cable Information Data Base (CONNAID) computer program, managing data base containing necessary information concerning electrical connectors, breakout boxes, adapter cables, backshells, and pertinent torque specifications for engineering project.

  3. Coaxial cable stripper for confined areas

    NASA Technical Reports Server (NTRS)

    Brown, J. D.; Lipscomb, W. G.

    1968-01-01

    Manual coaxial cable stripper quickly and accurately prepares a coaxial cable in a confined area. With this tool, preparation time is greatly reduced, and a completely inexperienced technician can perform the operation.

  4. Strain-Gauge Measurement of Weight of Fluid in a Tank

    NASA Technical Reports Server (NTRS)

    Figueroa, Jorge; St. Cyr, William; Rahman, Shamim; McVay, Gregory; Van Dyke, David; Mitchell, William; Langford, Lester

    2004-01-01

    A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods). The strain gauges used in this method may be of two types: foil and fiber-optic. Four foil gauges (full bridge) are mounted on each of the tank-supporting legs. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation. One or more fiber-optic gauges may be used instead of the foil gauges. The resolution of the fiber-optic and foil gauges is approximately the same, but the fiber-optic gauges are immune to EMI (electromagnetic interference), are linear with respect to temperature over their entire dynamic range (as defined by the behavior of the sample), and measure thermally induced deformations as predictable signals. Conversely, long term testing has demonstrated that the foil gauges exhibit an erratic behavior whenever subjected to direct sun radiation (even if protected with a rubberized cover). Henceforth, for deployment in outdoor conditions, fiber-optic gauges are the only option if one is to rely on the

  5. Comparison of cable ageing

    NASA Astrophysics Data System (ADS)

    Plaček, Vít; Kohout, Tomáš

    2010-03-01

    Two cable types, which currently are used in nuclear power plants (NPP) and which are composed by jacket/insulation materials, i.e. PVC/PVC and PVC/PE, were exposed to accelerated ageing conditions, in order to simulate their behavior after 10 years in service. The cables were aged under two different test conditions: With relatively high accelerating ageing speed:Radiation ageing was carried out at room temperature at a dose rate of 2900 Gy/h, followed by thermal ageing at 100 °C. This accelerated ageing condition was fairly fast, but still in compliance with the standards. With moderate ageing speed:The radiation and thermal ageing was performed simultaneously (superimposed) at a dose rate of 2.7-3.7Gy/h and a temperature of 68-70 °C. Such a test condition seems to be very close to the radiation and temperature impact onto the cables in the real NPP service. Finally, mechanical properties were measured to characterize the ageing status of the cables. The purpose of this study was to compare degradation effects, derived from both ageing methods, and to demonstrate that results obtained from high values of accelerating parameters and from fast ageing simulation can be very different from reality. The observed results corroborated this assumption.

  6. Antibiotic-Resistant Pathogenic Escherichia Coli Isolated from Rooftop Rainwater-Harvesting Tanks in the Eastern Cape, South Africa.

    PubMed

    Malema, Mokaba Shirley; Abia, Akebe Luther King; Tandlich, Roman; Zuma, Bonga; Mwenge Kahinda, Jean-Marc; Ubomba-Jaswa, Eunice

    2018-05-01

    Although many developing countries use harvested rainwater (HRW) for drinking and other household purposes, its quality is seldom monitored. Continuous assessment of the microbial quality of HRW would ensure the safety of users of such water. The current study investigated the prevalence of pathogenic Escherichia coli strains and their antimicrobial resistance patterns in HRW tanks in the Eastern Cape, South Africa. Rainwater samples were collected weekly between June and September 2016 from 11 tanks in various areas of the province. Enumeration of E. coli was performed using the Colilert ® 18/Quanti-Tray ® 2000 method. E. coli isolates were obtained and screened for their virulence potentials using polymerase chain reaction (PCR), and subsequently tested for antibiotic resistance using the disc-diffusion method against 11 antibiotics. The pathotype most detected was the neonatal meningitis E. coli (NMEC) ( ibeA 28%) while pathotype enteroaggregative E. coli (EAEC) was not detected. The highest resistance of the E. coli isolates was observed against Cephalothin (76%). All tested pathotypes were susceptible to Gentamicin, and 52% demonstrated multiple-antibiotic resistance (MAR). The results of the current study are of public health concern since the use of untreated harvested rainwater for potable purposes may pose a risk of transmission of pathogenic and antimicrobial-resistant E. coli.

  7. Antibiotic-Resistant Pathogenic Escherichia Coli Isolated from Rooftop Rainwater-Harvesting Tanks in the Eastern Cape, South Africa

    PubMed Central

    Malema, Mokaba Shirley; Tandlich, Roman; Zuma, Bonga; Mwenge Kahinda, Jean-Marc

    2018-01-01

    Although many developing countries use harvested rainwater (HRW) for drinking and other household purposes, its quality is seldom monitored. Continuous assessment of the microbial quality of HRW would ensure the safety of users of such water. The current study investigated the prevalence of pathogenic Escherichia coli strains and their antimicrobial resistance patterns in HRW tanks in the Eastern Cape, South Africa. Rainwater samples were collected weekly between June and September 2016 from 11 tanks in various areas of the province. Enumeration of E. coli was performed using the Colilert®18/Quanti-Tray® 2000 method. E. coli isolates were obtained and screened for their virulence potentials using polymerase chain reaction (PCR), and subsequently tested for antibiotic resistance using the disc-diffusion method against 11 antibiotics. The pathotype most detected was the neonatal meningitis E. coli (NMEC) (ibeA 28%) while pathotype enteroaggregative E. coli (EAEC) was not detected. The highest resistance of the E. coli isolates was observed against Cephalothin (76%). All tested pathotypes were susceptible to Gentamicin, and 52% demonstrated multiple-antibiotic resistance (MAR). The results of the current study are of public health concern since the use of untreated harvested rainwater for potable purposes may pose a risk of transmission of pathogenic and antimicrobial-resistant E. coli. PMID:29723970

  8. 65. CALIFORNIA STREET CABLE RAILWAY WINDING MACHINERY: Photocopy of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    65. CALIFORNIA STREET CABLE RAILWAY - WINDING MACHINERY: Photocopy of February 1955 photograph showing the winding machinery of the California Street Cable Railroad. The two suspended sheaves on the right of the photograph bore down on the cable as it left the winders, supplying tension to the cable and eliminating the need for a long tension run. - San Francisco Cable Railway, Washington & Mason Streets, San Francisco, San Francisco County, CA

  9. Cable Television: Notebook Number Five.

    ERIC Educational Resources Information Center

    Notebook, 1973

    1973-01-01

    Cable television has been introduced to the public as a revolutionary development in communications, but its history, evolving structure, and present operation indicate otherwise. A few large industrial conglomerates have come to dominate the field of cable television and studies by private institutions and the regulatory activities of the Federal…

  10. Cable Television in Sedalia, Missouri.

    ERIC Educational Resources Information Center

    Lamkin, Kathryn Janel

    A field study was conducted of the status of cable television in Sedalia, Missouri. Based on interviews of city council members and staff members of Cablevision, the Sedalia cable franchise holder, the following issues were investigated: (1) subscription rates; (2) franchise negotiations; (3) quality of existing services; and (4) possible…

  11. Development of a single-phase 30 m HTS power cable

    NASA Astrophysics Data System (ADS)

    Cho, Jeonwook; Bae, Joon-Han; Kim, Hae-Jong; Sim, Ki-Deok; Kim, Seokho; Jang, Hyun-Man; Lee, Chang-Young; Kim, Dong-Wook

    2006-05-01

    HTS power transmission cables appear to be the replacement and retrofitting of underground cables in urban areas and HTS power transmission cable offers a number of technical and economic merits compared to the normal conductor cable system. A 30 m long, single-phase 22.9 kV class HTS power transmission cable system has been developed by Korea Electrotechnology Research Institute (KERI), LS Cable Ltd., and Korea Institute of Machinery and Materials (KIMM), which is one of the 21st century frontier project in Korea since 2001. The HTS power cable has been developed, cooled down and tested to obtain realistic thermal and electrical data on HTS power cable system. The evaluation results clarified such good performance of HTS cable that DC critical current of the HTS cable was 3.6 kA and AC loss was 0.98 W/m at 1260 Arms and shield current was 1000 Arms. These results proved the basic properties for 22.9 kV HTS power cable. As a next step, we have been developing a 30 m, three-phase 22.9 kV, 50 MV A HTS power cable system and long term evaluation is in progress now.

  12. High power cable with internal water cooling 400 kV

    NASA Astrophysics Data System (ADS)

    Rasquin, W.; Harjes, B.

    1982-08-01

    Due to the concentration of electricity production in large power plants, the need of higher power transmissions, and the protection of environment, developement of a 400 kV water cooled cable in the power range of 1 to 5 GVA was undertaken. The fabrication and testing of equipment, engineering of cable components, fabrication of a test cable, development of cable terminal laboratory, testing of test cable, field testing of test cable, fabrication of industrial cable laboratory, testing of industrial cable, field testing of industrial cable, and system analysis for optimization were prepared. The field testing was impossible to realize. However, it is proved that a cable consisting of an internal stainless steel water cooled tube, covered by stranded copper profiles, insulated with heavy high quality paper, and protected by an aluminum cover can be produced, withstand tests accordingly to IEC/VDE recommendations, and is able to fulfill all exploitation conditions.

  13. TankSIM: A Cryogenic Tank Performance Prediction Program

    NASA Technical Reports Server (NTRS)

    Bolshinskiy, L. G.; Hedayat, A.; Hastings, L. J.; Moder, J. P.; Schnell, A. R.; Sutherlin, S. G.

    2015-01-01

    Accurate prediction of the thermodynamic state of the cryogenic propellants in launch vehicle tanks is necessary for mission planning and successful execution. Cryogenic propellant storage and transfer in space environments requires that tank pressure be controlled. The pressure rise rate is determined by the complex interaction of external heat leak, fluid temperature stratification, and interfacial heat and mass transfer. If the required storage duration of a space mission is longer than the period in which the tank pressure reaches its allowable maximum, an appropriate pressure control method must be applied. Therefore, predictions of the pressurization rate and performance of pressure control techniques in cryogenic tanks are required for development of cryogenic fluid long-duration storage technology and planning of future space exploration missions. This paper describes an analytical tool, Tank System Integrated Model (TankSIM), which can be used for modeling pressure control and predicting the behavior of cryogenic propellant for long-term storage for future space missions. It is written in the FORTRAN 90 language and can be compiled with any Visual FORTRAN compiler. A thermodynamic vent system (TVS) is used to achieve tank pressure control. Utilizing TankSIM, the following processes can be modeled: tank self-pressurization, boiloff, ullage venting, and mixing. Details of the TankSIM program and comparisons of its predictions with test data for liquid hydrogen and liquid methane will be presented in the final paper.

  14. Space Transportation System (STS)-117 External Tank (ET)-124 Hail Damage Repair Assessment

    NASA Technical Reports Server (NTRS)

    Wilson, Timmy R.; Gentz, Steven J.; Barth, Timothy S.; Minute, Stephen A.; Flowers, Cody P.; Hamilton, David A.; Null, Cynthia H.; Schafer, Charles F.

    2009-01-01

    Severe thunderstorms with associated hail and high winds struck the STS-117 stack on February 26, 2007. Peak winds were recorded at 62 knots with hail sizes ranging from 0.3 inch to 0.8 inch in diameter. As a result of the storm, the North Carolina Foam Institute (NCFI) type 24-124 Thermal Protection System (TPS) foam on the liquid oxygen (LO2) ogive acreage incurred significant impact damage. The NCFI on the ET intertank and the liquid hydrogen (LH2) acreage sustained hail damage. The Polymer Development Laboratory (PDL)-1034 foam of the LO2 ice frost ramps (IFRs) and the Super-Lightweight Ablator (SLA) of the LO2 cable tray also suffered minor damage. NASA Engineering and Safety Center (NESC) was asked to assess the technical feasibility of repairing the ET TPS, the reasonableness of conducting those repairs with the vehicle in a vertical, integrated configuration at the Kennedy Space Center (KSC) Vehicle Assemble Building (VAB), and to address attendant human factors considerations including worker fatigue and the potential for error. The outcome of the assessment is recorded in this document.

  15. 47 CFR 15.213 - Cable locating equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...: Within the frequency band 9 kHz, up to, but not including, 45 kHz, the peak output power from the cable... output power from the cable locating equipment shall not exceed one watt. If provisions are made for connection of the cable locating equipment to the AC power lines, the conducted limits in § 15.207 also apply...

  16. 47 CFR 15.213 - Cable locating equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...: Within the frequency band 9 kHz, up to, but not including, 45 kHz, the peak output power from the cable... output power from the cable locating equipment shall not exceed one watt. If provisions are made for connection of the cable locating equipment to the AC power lines, the conducted limits in § 15.207 also apply...

  17. 47 CFR 15.213 - Cable locating equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...: Within the frequency band 9 kHz, up to, but not including, 45 kHz, the peak output power from the cable... output power from the cable locating equipment shall not exceed one watt. If provisions are made for connection of the cable locating equipment to the AC power lines, the conducted limits in § 15.207 also apply...

  18. 47 CFR 15.213 - Cable locating equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...: Within the frequency band 9 kHz, up to, but not including, 45 kHz, the peak output power from the cable... output power from the cable locating equipment shall not exceed one watt. If provisions are made for connection of the cable locating equipment to the AC power lines, the conducted limits in § 15.207 also apply...

  19. Coaxial cable cutter

    DOEpatents

    Hall, Leslie C.; Hedges, Robert S.

    1990-04-10

    A cutting device is provided which is useful in trimming the jackets from semi-rigid coaxial cables and wire having a cutting bit and support attached to movable jaws. A thumbpiece is provided to actuate the opening of the jaws for receiving the cable to be trimmed, and a spring member is provided to actuate the closing of the jaws when thumbpiece is released. The cutting device utilizes one moving part during the cutting operation by using a rolling cut action. The nature of the jaws allows the cutting device to work in space having clearances less than 0.160 inches.

  20. New Opportunities for Cabled Ocean Observatories

    NASA Astrophysics Data System (ADS)

    Duennebier, F. K.; Butler, R.; Karl, D. M.; Roger, L. B.

    2002-12-01

    With the decommissioning of transoceanic telecommunications cables as they become obsolete or uneconomical, there is an opportunity to use these systems for ocean observatories. Two coaxial cables, TPC-1 and HAW-2 are currently in use for observatories, and another, ANZCAN, is scheduled to be used beginning in 2004 to provide a cabled observatory at Station ALOHA, north of Oahu. The ALOHA observatory will provide several Mb/s data rates and about 1 kW of power to experiments installed at Station ALOHA. Sensors can be installed either by wet mateable connection to a junction box on the ocean floor using an ROV, or by acoustic data link to the system. In either case real-time data will be provided to users over the Internet. A Small Experiment Module, to be first installed at the Hawaii-2 Observatory, and later at Station ALOHA, will provide relatively cheap and uncomplicated access to the observatories for relatively simple sensors. Within the next few years, the first electro-optical cables installed in the 1980's will be decommissioned and could be available for scientific use. These cables could provide long "extension cords" (thousands of km) with very high bandwidth and reasonable power to several observatories in remote locations in the ocean. While they could be used in-place, a more exciting scenario is to use cable ships to pick up sections of cable and move them to locations of higher scientific interest. While such moves would not be cheap, the costs would rival the cost of installation and maintenance of a buoyed observatory, with far more bandwidth and power available for science use.

  1. Cable attachment for a radioactive brachytherapy source capsule

    DOEpatents

    Gross, Ian G; Pierce, Larry A

    2006-07-18

    In cancer brachytherapy treatment, a small californium-252 neutron source capsule is attached to a guide cable using a modified crimping technique. The guide cable has a solid cylindrical end, and the attachment employs circumferential grooves micromachined in the solid cable end. The attachment was designed and tested, and hardware fabricated for use inside a radioactive hot cell. A welding step typically required in other cable attachments is avoided.

  2. Apparatus producing constant cable tension for intermittent demand

    DOEpatents

    Lauritzen, T.

    1984-05-23

    This invention relates to apparatus for producing constant tension in cable or the like when it is unreeled and reeled from a drum or spool under conditions of intermittent demand. The invention is particularly applicable to the handling of superconductive cable, but the invention is also applicable to the unreeling and reeling of other strands, such as electrical cable, wire, cord, other cables, fish line, wrapping paper and numerous other materials.

  3. Woven ribbon cable for cryogenic instruments

    NASA Astrophysics Data System (ADS)

    Cunningham, C. R.; Hastings, P. R.; Strachan, J. M. D.

    Robust woven ribbon cables are described for connecting sensors at low temperatures to higher temperature systems. Woven cables have several advantages over conventional wiring or flat ribbon cables in cryostats: heat sinking is easier; twisted pairs may be used; and miniature multi-way connectors are easily incorporated. Their use is demonstrated in making connections from 131 bolometers in two arrays mounted in a dilution refrigerator at 100 mK. Thermal and electrical properties are discussed, as are other possible applications in cryogenic instruments.

  4. Cable-to-post attachments for use in non-proprietary high-tension cable median barrier - phase II.

    DOT National Transportation Integrated Search

    2016-03-24

    The objective of this study was to reevaluate and improve the existing cable-to-post attachment hardware that is utilized : in the non-proprietary cable barrier being developed at MwRSF. The study focused on redesigning the bolted, tabbed : bracket (...

  5. What Belongs On the Cable.

    ERIC Educational Resources Information Center

    Ward, John E.

    Many papers and articles over the past few years have suggested that the coaxial cable television (CATV) cable carries sufficient bandwidth into and out of the home that it can serve almost every conceivable communications need--providing many television viewing channels; two-way data, audio and data services; the functions of the present…

  6. 30 CFR 75.604 - Permanent splicing of trailing cables.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Permanent splicing of trailing cables. 75.604... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Trailing Cables § 75.604 Permanent splicing of trailing cables. [Statutory Provisions] When permanent splices in trailing cables are made...

  7. 27 CFR 24.229 - Tank car and tank truck requirements.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Tank car and tank truck... BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL WINE Spirits § 24.229 Tank car and tank truck requirements. Railroad tank cars and tank trucks used to transport spirits for use in wine production will be constructed...

  8. 27 CFR 24.229 - Tank car and tank truck requirements.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Tank car and tank truck... BUREAU, DEPARTMENT OF THE TREASURY LIQUORS WINE Spirits § 24.229 Tank car and tank truck requirements. Railroad tank cars and tank trucks used to transport spirits for use in wine production will be constructed...

  9. 27 CFR 24.229 - Tank car and tank truck requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Tank car and tank truck... BUREAU, DEPARTMENT OF THE TREASURY LIQUORS WINE Spirits § 24.229 Tank car and tank truck requirements. Railroad tank cars and tank trucks used to transport spirits for use in wine production will be constructed...

  10. 27 CFR 24.229 - Tank car and tank truck requirements.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Tank car and tank truck... BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL WINE Spirits § 24.229 Tank car and tank truck requirements. Railroad tank cars and tank trucks used to transport spirits for use in wine production will be constructed...

  11. 27 CFR 24.229 - Tank car and tank truck requirements.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Tank car and tank truck... BUREAU, DEPARTMENT OF THE TREASURY LIQUORS WINE Spirits § 24.229 Tank car and tank truck requirements. Railroad tank cars and tank trucks used to transport spirits for use in wine production will be constructed...

  12. Nondestructive Examination for Nuclear Power Plant Cable Aging Management Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glass, Samuel W.; Fifield, Leonard S.

    2016-01-01

    Degradation of the cable jacket, electrical insulation, and other cable components of installed cables within nuclear power plants (NPPs) is known to occur as a function of age, temperature, radiation, and other environmental factors. System tests verify cable function under normal loads; however, the concern is over cable performance under exceptional loads associated with design-basis events (DBEs). The cable’s ability to perform safely over the initial 40 year planned and licensed life has generally been demonstrated and there have been very few age-related cable failures. With greater than 1000 km of power, control, instrumentation, and other cables typically found inmore » an NPP, replacing all the cables would be a severe cost burden. Justification for life extension to 60 and 80 years requires a cable aging management program (AMP) to justify cable performance under normal operation as well as accident conditions. This paper addresses various NDE technologies that constitute the essence of an acceptable aging management program.« less

  13. Antenna Mechanism of Length Control of Actin Cables

    PubMed Central

    Mohapatra, Lishibanya; Goode, Bruce L.; Kondev, Jane

    2015-01-01

    Actin cables are linear cytoskeletal structures that serve as tracks for myosin-based intracellular transport of vesicles and organelles in both yeast and mammalian cells. In a yeast cell undergoing budding, cables are in constant dynamic turnover yet some cables grow from the bud neck toward the back of the mother cell until their length roughly equals the diameter of the mother cell. This raises the question: how is the length of these cables controlled? Here we describe a novel molecular mechanism for cable length control inspired by recent experimental observations in cells. This “antenna mechanism” involves three key proteins: formins, which polymerize actin, Smy1 proteins, which bind formins and inhibit actin polymerization, and myosin motors, which deliver Smy1 to formins, leading to a length-dependent actin polymerization rate. We compute the probability distribution of cable lengths as a function of several experimentally tuneable parameters such as the formin-binding affinity of Smy1 and the concentration of myosin motors delivering Smy1. These results provide testable predictions of the antenna mechanism of actin-cable length control. PMID:26107518

  14. Antenna Mechanism of Length Control of Actin Cables.

    PubMed

    Mohapatra, Lishibanya; Goode, Bruce L; Kondev, Jane

    2015-06-01

    Actin cables are linear cytoskeletal structures that serve as tracks for myosin-based intracellular transport of vesicles and organelles in both yeast and mammalian cells. In a yeast cell undergoing budding, cables are in constant dynamic turnover yet some cables grow from the bud neck toward the back of the mother cell until their length roughly equals the diameter of the mother cell. This raises the question: how is the length of these cables controlled? Here we describe a novel molecular mechanism for cable length control inspired by recent experimental observations in cells. This "antenna mechanism" involves three key proteins: formins, which polymerize actin, Smy1 proteins, which bind formins and inhibit actin polymerization, and myosin motors, which deliver Smy1 to formins, leading to a length-dependent actin polymerization rate. We compute the probability distribution of cable lengths as a function of several experimentally tuneable parameters such as the formin-binding affinity of Smy1 and the concentration of myosin motors delivering Smy1. These results provide testable predictions of the antenna mechanism of actin-cable length control.

  15. Superconducting Cable

    DOEpatents

    Hughey, Raburn L.; Sinha, Uday K.; Reece, David S.; Muller, Albert C.

    2005-03-08

    In order to provide a flexible oxide superconducting cable which is reduced in AC loss, tape-shaped superconducting wires covered with a stabilizing metal are wound on a flexible former. The superconducting wires are preferably laid on the former at a bending strain of not more than 0.2%. In laying on the former, a number of tape-shaped superconducting wires are laid on a core member in a side-by-side manner, to form a first layer. A prescribed number of tape-shaped superconducting wires are laid on top of the first layer in a side-by-side manner, to form a second layer. The former may be made of a metal, plastic, reinforced plastic, polymer, or a composite and provides flexibility to the superconducting wires and the cable formed therewith.

  16. Superconducting Cable

    DOEpatents

    Hughey, Raburn L.; Sinha, Uday K.; Reece, David S.; Muller, Albert C.

    2005-07-22

    In order to provide a flexible oxide superconducting cable which is reduced in AC loss, tape-shaped superconducting wires covered with a stabilizing metal are wound on a flexible former. The superconducting wires are preferably laid on the former at a bending strain of not more than 0.2%. In laying on the former, a number of tape-shaped superconducting wires are laid on a core member in a side-by-side manner, to form a first layer. A prescribed number of tape-shaped superconducting wires are laid on top of the first layer in a side-by-side manner, to form a second layer. The former may be made of a metal, plastic, reinforced plastic, polymer, or a composite and provides flexibility to the superconducting wires and the cable formed therewith.

  17. A systems-biology approach to yeast actin cables.

    PubMed

    Drake, Tyler; Yusuf, Eddy; Vavylonis, Dimitrios

    2012-01-01

    We focus on actin cables in yeast as a model system for understanding cytoskeletal organization and the workings of actin itself. In particular, we highlight quantitative approaches on the kinetics of actin-cable assembly and methods of measuring their morphology by image analysis. Actin cables described by these studies can span greater lengths than a thousand end-to-end actin-monomers. Because of this difference in length scales, control of the actin-cable system constitutes a junction between short-range interactions - among actin-monomers and nucleating, polymerization-facilitating, side-binding, severing, and cross-linking proteins - and the emergence of cell-scale physical form as embodied by the actin cables themselves.

  18. Submarine optical fiber cable: development and laying results.

    PubMed

    Kojima, N; Yabuta, T; Negishi, Y; Iwabuchi, K; Kawata, O; Yamashita, K; Miyajima, Y; Yoshizawa, N

    1982-03-01

    This paper describes the structural design, trial production, and laying results for submarine optical fiber cables that can be deployed in shallow seas between islands and/or channel crossings without repeaters. Structural design methods for the submarine optical fiber cable are proposed, which take into consideration suppressing cable elongation under tension and excess loss under hydraulic pressure. This paper describes good laying results for the cable using this structural design method. The average loss for single-mode fibers was 0.72 dB/km, and the average loss for multimode fibers was 0.81 dB/km for a 10.2-km long cable operated at 1.3-microm wavelength.

  19. 30 CFR 75.603 - Temporary splice of trailing cable.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Temporary splice of trailing cable. 75.603... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Trailing Cables § 75.603 Temporary splice of trailing cable. [Statutory Provision] One temporary splice may be made in any trailing cable...

  20. 30 CFR 77.602 - Permanent splicing of trailing cables.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Permanent splicing of trailing cables. 77.602... COAL MINES Trailing Cables § 77.602 Permanent splicing of trailing cables. When permanent splices in trailing cables are made, they shall be: (a) Mechanically strong with adequate electrical conductivity; (b...

  1. 30 CFR 75.833 - Handling high-voltage trailing cables.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Handling high-voltage trailing cables. 75.833... High-Voltage Longwalls § 75.833 Handling high-voltage trailing cables. (a) Cable handling. (1) Miners must not handle energized trailing cables unless they are wearing high-voltage insulating gloves, which...

  2. Optimal Design of Cable-Driven Manipulators Using Particle Swarm Optimization.

    PubMed

    Bryson, Joshua T; Jin, Xin; Agrawal, Sunil K

    2016-08-01

    The design of cable-driven manipulators is complicated by the unidirectional nature of the cables, which results in extra actuators and limited workspaces. Furthermore, the particular arrangement of the cables and the geometry of the robot pose have a significant effect on the cable tension required to effect a desired joint torque. For a sufficiently complex robot, the identification of a satisfactory cable architecture can be difficult and can result in multiply redundant actuators and performance limitations based on workspace size and cable tensions. This work leverages previous research into the workspace analysis of cable systems combined with stochastic optimization to develop a generalized methodology for designing optimized cable routings for a given robot and desired task. A cable-driven robot leg performing a walking-gait motion is used as a motivating example to illustrate the methodology application. The components of the methodology are described, and the process is applied to the example problem. An optimal cable routing is identified, which provides the necessary controllable workspace to perform the desired task and enables the robot to perform that task with minimal cable tensions. A robot leg is constructed according to this routing and used to validate the theoretical model and to demonstrate the effectiveness of the resulting cable architecture.

  3. The optimum spanning catenary cable

    NASA Astrophysics Data System (ADS)

    Wang, C. Y.

    2015-03-01

    A heavy cable spans two points in space. There exists an optimum cable length such that the maximum tension is minimized. If the two end points are at the same level, the optimum length is 1.258 times the distance between the ends. The optimum lengths for end points of different heights are also found.

  4. Cable Television and Public Safety.

    ERIC Educational Resources Information Center

    Cranberg, Gilbert

    One of the most promising applications of cable television (CATV) is municipal surveillance of public areas for protection against crime, fire detection, control of air pollution, and traffic. Thus far, however, the CATV industry has made minimal efforts to realize the potential of CATV for community protection--the use of cable for public safety…

  5. Protecting Against Failure.

    ERIC Educational Resources Information Center

    Hammond, Edward; Hall, John

    1998-01-01

    Examines the need for power reliability when educational facilities incorporate communications infrastructures. Telecommunications equipment placement and environmental conditions are addressed, as are the integrating of cable trays and conduit systems, developing surge-suppression, and building grounding systems. (GR)

  6. 30 CFR 75.810 - High-voltage trailing cables; splices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage trailing cables; splices. 75.810... § 75.810 High-voltage trailing cables; splices. [Statutory Provisions] In the case of high-voltage cables used as trailing cables, temporary splices shall not be used and all permanent splices shall be...

  7. 30 CFR 18.35 - Portable (trailing) cables and cords.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Portable (trailing) cables and cords. 18.35... and Design Requirements § 18.35 Portable (trailing) cables and cords. (a) Portable cables and cords... a portable (trailing) cable shall not exceed 500 feet. Where the method of mining requires the...

  8. Regulations; Office of Cable Television, State of New Jersey.

    ERIC Educational Resources Information Center

    New Jersey State Dept. of Public Utilities, Trenton. Office of Cable Television.

    Regulations promulgated in accordance with the authority provided the Office of Cable Television, Board of Public Utility Commissioners, State of New Jersey, to regulate cable television in the public interest are set forth. These apply to cable television (CATV) companies which own, control, operate, or manage cable television systems and to…

  9. Mechanisms of Cables 1 gene inactivation in human ovarian cancer development.

    PubMed

    Sakamoto, Hideo; Friel, Anne M; Wood, Antony W; Guo, Lankai; Ilic, Ana; Seiden, Michael V; Chung, Daniel C; Lynch, Maureen P; Serikawa, Takehiro; Munro, Elizabeth; Oliva, Esther; Orsulic, Sandra; Kirley, Sandra D; Foster, Rosemary; Zukerberg, Lawrence R; Rueda, Bo R

    2008-02-01

    Cables 1, a cyclin-dependent kinase binding protein, is primarily involved in cell cycle regulation. Loss of nuclear Cables 1 expression is observed in human colon, lung and endometrial cancers. We previously reported that loss of nuclear Cables 1 expression was also observed with high frequency in a limited sample set of human ovarian carcinomas, although the mechanisms underlying loss of nuclear Cables 1 expression remained unknown. Our present objective was to examine Cables 1 expression in ovarian cancer in greater detail, and determine the predominant mechanisms of Cables 1 loss. We assessed potential genetic and epigenetic modifications of the Cables 1 locus through analyses of mutation, polymorphisms, loss of heterozygosity and DNA methylation. We observed a marked loss of nuclear Cables 1 expression in serous and endometrioid ovarian carcinomas that correlated with decreased Cables 1 mRNA levels. Although we detected no Cables 1 mutations, there was evidence of LOH at the Cables 1 locus and epigenetic modification of the Cables 1 promoter region in a subset of ovarian carcinomas and established cancer cell lines. From a functional perspective, over-expression of Cables 1 induced apoptosis, whereas, knockdown of Cables 1 negated this effect. Together these findings suggest that multiple mechanisms underlie the loss of Cables 1 expression in ovarian cancer cells, supporting the hypothesis that Cables 1 is a tumor suppressor in human ovarian cancer.

  10. Smaller but Fully Functional Backshell for Cable Connector

    NASA Technical Reports Server (NTRS)

    Stephenson, Gregory

    2009-01-01

    An improved design for the backshell of a connector for a shielded, multiplewire cable reduces the size of the backshell, relative to traditional designs of backshells of otherwise identical cable connectors. Notwithstanding the reduction in size, the design provides all the functionality typically demanded of such a backshell, including (1) termination of the cable shield (that is, grounding of the shield to the backshell), (2) strain relief for the cable, and (3) protection against electromagnetic interference (EMI).

  11. Experimental Measurements and Comparison of Cable Performance for Mine Hunting Applications

    NASA Astrophysics Data System (ADS)

    Mangum, Katherine

    2005-11-01

    The Naval Surface Warfare Center (NSWCCD) conducted testing of multiple faired synthetic cables in the High Speed Basin in April, 2005. The objective of the test was to determine the hydrodynamic characteristics of bare cables, ribbon faired cables, and cables with extruded plastic ``strakes.'' Faired cables are used to gain on-station time and improve performance of the MH-60 Helicopter when towing mine hunting vehicles. Drag and strum were compared for all cases. Strum was quantified by computing standard deviations of lateral cable acceleration amplitudes. Drag coefficients were calculated using cable tension and angle readings. While the straked cables strummed less than the bare synthetic cable, they did not reduce strum levels as well as ribbon fairing at steep cable angles for speeds of 10, 15, 20 and 25 knots. The drag coefficient of the straked cables was calculated to be higher than that of a bare cable, although further testing is needed to determine an exact number.

  12. 49 CFR 180.519 - Periodic retest and inspection of tank cars other than single-unit tank car tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Periodic retest and inspection of tank cars other than single-unit tank car tanks. 180.519 Section 180.519 Transportation Other Regulations Relating to... of Tank Cars § 180.519 Periodic retest and inspection of tank cars other than single-unit tank car...

  13. The Uses of Cable Communications.

    ERIC Educational Resources Information Center

    Cable Television Information Center, Washington, DC.

    Only by having an appreciation of how cable systems can be used, the attendant costs and limitations, can local authorities rationally evaluate its impact on the community. This report is intended to provide an introduction to the range of uses and communications services now possible with cable systems. The first part of the report includes a…

  14. Cable Television: Uses in Education.

    ERIC Educational Resources Information Center

    Carpenter, Polly

    This is the first volume of a two-part study of the role of cable television in education; its purposes are to discuss the implications of the Federal Communications Commission (FCC) ruling that all cable systems in the top 100 markets must reserve one channel for educational purposes and to stimulate the interests of educators by making them…

  15. Possibilities and Limitations of Cable TV for Adult Education.

    ERIC Educational Resources Information Center

    Niemi, John A.

    The paper investigates various organizational models of cable TV ownership and control, legislation in Canada and the United States regarding cable systems, and the potential of cable as an information network for adult education. With a view to giving everyone access to the cable medium and an opportunity to participate, advantages and…

  16. Communications Via Undersea Cables: Present And Future

    NASA Astrophysics Data System (ADS)

    Paul, D. K.

    1985-11-01

    Advances in fiber optic technology in the past few years have firmly established the superiority of optical fiber to coaxial cables, particularly for large-capacity, long-haul transmission systems. Recently, several undersea fiber optic cable systems have been proposed by both common and noncommon carriers. This paper addresses the techno-economic implications of these applications, and includes a brief review of the current status of undersea cable technology and a projection of future demand and capabilities. The prospects for using high-speed, multifiber undersea cable systems for international communications, extension of these systems through fiber optic terrestrial distribution, and future developmental trends are critically assessed.

  17. A case of gamasoidosis associated with exposure to a wild lorikeet feeding tray.

    PubMed

    Warren, Matthew; Tritton, Sara; Abbott, Nicola Cd; Sim, Sarah; Strutton, Geoffrey M; Soyer, H Peter

    2016-05-01

    Gamasoidosis (acariasis, avian-mite dermatitis or bird-mite dermatitis) is caused by members of the mite superfamily Dermanyssoidea. The mites lay their eggs on the nest of the birds they feed on. The also leave the nest and feed on humans if there is no bird host available. The bites result in urticated plaques and papules. Here we present a case of gamasoidosis from exposure to a wild lorikeet feeding tray. © 2015 The Australasian College of Dermatologists.

  18. System and method for sub-sea cable termination

    DOEpatents

    Chen, Qin; Yin, Weijun; Zhang, Lili

    2016-04-05

    An electrical connector includes a first cable termination chamber configured to receive a first power cable having at least a first conductor sheathed at least in part by a first insulating layer and a first insulation screen layer. Also, the electrical connector includes a first non-linear resistive layer configured to be coupled to a portion of the first conductor unsheathed by at least the first insulation screen layer and configured to control a direct current electric field generated in the first cable termination chamber. In addition, the electrical connector includes a first deflector configured to be coupled to the first power cable and control an alternating current electric field generated in the first cable termination chamber.

  19. A Systems-Biology Approach to Yeast Actin Cables

    PubMed Central

    Drake, Tyler; Yusuf, Eddy; Vavylonis, Dimitrios

    2011-01-01

    We focus on actin cables in yeast as a model system for understanding cytoskeletal organization and the workings of actin itself. In particular, we highlight quantitative approaches on the kinetics of actin cable assembly and methods of measuring their morphology by image analysis. Actin cables described by these studies can span greater lengths than a thousand end-to-end actin monomers. Because of this difference in length scales, control of the actin-cable system constitutes a junction between short-range interactions—among actin monomers and nucleating, polymerization-facilitating, side-binding, severing, and cross-linking proteins—and the emergence of cell-scale physical form as embodied by the actin cables themselves. PMID:22161338

  20. Two hundred passage three-way valve: Fraction collector

    NASA Technical Reports Server (NTRS)

    Keffer, J. L.

    1983-01-01

    This paper describes the design and operation of a fraction collector used to direct flow of separated biological materials from 197 capillary tubes to either a collection tray or to a waste tank. This mechanism uses a 28-volt dc gear motor driving twin cams to force 197 needles through a self-sealing silicone rubber septum, where they inject the material in 197 separate pockets in a collection tray. The position of the collector tray is sensed by two optical limit switches. The time sequences are controlled automatically by an electronics control monitoring module.

  1. Total Magnetic Field Signatures over Submarine HVDC Power Cables

    NASA Astrophysics Data System (ADS)

    Johnson, R. M.; Tchernychev, M.; Johnston, J. M.; Tryggestad, J.

    2013-12-01

    Mikhail Tchernychev, Geometrics, Inc. Ross Johnson, Geometrics, Inc. Jeff Johnston, Geometrics, Inc. High Voltage Direct Current (HVDC) technology is widely used to transmit electrical power over considerable distances using submarine cables. The most commonly known examples are the HVDC cable between Italy and Greece (160 km), Victoria-Tasmania (300 km), New Jersey - Long Island (82 km) and the Transbay cable (Pittsburg, California - San-Francisco). These cables are inspected periodically and their location and burial depth verified. This inspection applies to live and idle cables; in particular a survey company could be required to locate pieces of a dead cable for subsequent removal from the sea floor. Most HVDC cables produce a constant magnetic field; therefore one of the possible survey tools would be Marine Total Field Magnetometer. We present mathematical expressions of the expected magnetic fields and compare them with fields observed during actual surveys. We also compare these anomalies fields with magnetic fields produced by other long objects, such as submarine pipelines The data processing techniques are discussed. There include the use of Analytic Signal and direct modeling of Total Magnetic Field. The Analytic Signal analysis can be adapted using ground truth where available, but the total field allows better discrimination of the cable parameters, in particular to distinguish between live and idle cable. Use of a Transverse Gradiometer (TVG) allows for easy discrimination between cable and pipe line objects. Considerable magnetic gradient is present in the case of a pipeline whereas there is less gradient for the DC power cable. Thus the TVG is used to validate assumptions made during the data interpretation process. Data obtained during the TVG surveys suggest that the magnetic field of a live HVDC cable is described by an expression for two infinite long wires carrying current in opposite directions.

  2. 30 CFR 57.12003 - Trailing cable overload protection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Trailing cable overload protection. 57.12003... Electricity Surface and Underground § 57.12003 Trailing cable overload protection. Individual overload protection or short circuit protection shall be provided for the trailing cables of mobile equipment. ...

  3. 47 CFR 76.403 - Cable television system reports.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 4 2013-10-01 2013-10-01 false Cable television system reports. 76.403 Section 76.403 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Forms and Reports § 76.403 Cable television system reports. The...

  4. 47 CFR 76.403 - Cable television system reports.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Cable television system reports. 76.403 Section 76.403 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Forms and Reports § 76.403 Cable television system reports. The...

  5. 47 CFR 76.403 - Cable television system reports.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Cable television system reports. 76.403 Section 76.403 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Forms and Reports § 76.403 Cable television system reports. The...

  6. Crystal River 3 Cable Materials for Thermal and Gamma Radiation Aging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fifield, Leonard S.; Correa, Miguel; Zwoster, Andy

    The Expanded Materials Degradation Assessment Volume 5: Aging of Cables and Cable Systems (EMDA) summarizes the state of knowledge of materials, constructions, operating environments, and aging behavior of low voltage and medium cables in nuclear power plants (NPPs) and identifies potential knowledge gaps with regard to cable operation beyond 60 years. The greatest area of uncertainty relates to how well the accelerated aging used in the original equipment qualification (EQ) processes predicts the performance of cable materials in extended operation. General opinion and utility experience have indicated that actual operating environments of in-plant cables are not as severe, however, asmore » the operating and design basis environments used in the qualification process. Better understanding of the long term aging behavior of cable insulation materials in service conditions and the analysis of actual cable operating environments are the objectives of ongoing research to support subsequent license renewal activities in particular and long term cable aging management in general. A key component of the effort to better understand cable material aging behavior is the availability of representative samples of cables that have been installed in operating light water reactors and have experienced long term service. Unique access to long term service cables, including relatively rich information on cable identity and history, occurred in 2016 through the assistance of the Electric Power Research Institute (EPRI). EPRI facilitated DOE receipt of harvested cables from the decommissioned Crystal River Unit 3 (CR3) pressurized water reactor representing six of the nine most common low voltage cable manufacturers (EPRI 103841R1): Rockbestos, Anaconda Wire and Cable Company (Anaconda), Boston Insulated Wire (BIW), Brand-Rex, Kerite and Okonite. Cable samples received had been installed in the operating plant for durations ranging from 10 years to 36 years. These cables provide

  7. 68. GENERAL VIEW OF SOUTH AND EAST SIDES OF SLC3W ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    68. GENERAL VIEW OF SOUTH AND EAST SIDES OF SLC-3W LIQUID OXYGEN APRON. CABLE TRAYS IN FOREGROUND - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  8. Rapid optimization of tension distribution for cable-driven parallel manipulators with redundant cables

    NASA Astrophysics Data System (ADS)

    Ouyang, Bo; Shang, Weiwei

    2016-03-01

    The solution of tension distributions is infinite for cable-driven parallel manipulators(CDPMs) with redundant cables. A rapid optimization method for determining the optimal tension distribution is presented. The new optimization method is primarily based on the geometry properties of a polyhedron and convex analysis. The computational efficiency of the optimization method is improved by the designed projection algorithm, and a fast algorithm is proposed to determine which two of the lines are intersected at the optimal point. Moreover, a method for avoiding the operating point on the lower tension limit is developed. Simulation experiments are implemented on a six degree-of-freedom(6-DOF) CDPM with eight cables, and the results indicate that the new method is one order of magnitude faster than the standard simplex method. The optimal distribution of tension distribution is thus rapidly established on real-time by the proposed method.

  9. Thin film conductors for self-equalizing cables

    NASA Astrophysics Data System (ADS)

    Owen, G.; Trutna, W. R.; Orsley, T. J.; Lucia, F.; Daly, C. B.

    2017-10-01

    Self-equalizing cables using hollow conductors with wall thickness less than the skin depth were proposed in 1929. However, they do not appear ever to have been widely used, although the idea has resurfaced and been refined from time to time. In the early 2000's, self-equalizing conductors consisting of solid magnetic steel cores coated with silver were developed by W.L. Gore, and used in their 2.5 Gb/s "Eye-Opener" cables, although higher speed versions never appeared. We have revived the original 1929 idea, proposing to use glass as a solid insulating core. This technology can potentially work at frequencies of many 10's of GHz. Possible uses include short range GHz links such as USB and Thunderbolt, and intra-rack interconnections in data centers. Our feasibility experiments have validated the principle. Copper coated glass fibers can, in principle, be manufactured, but in these tests, the conductors were capillaries internally coated with silver as these are easily obtainable, relatively inexpensive and serve to test the concept. The performance of these experimental twin lead cables corresponds to calculations, confirming the general principle. By calculation, we have compared the performance of cables made from copper-on-insulator conductors to that of similar cables made with solid copper conductors, and verified that copper-on-insulator cables have significantly less frequency dependent loss. We have also made and tested cables with copper on PEEK conductors as surrogates for copper on glass fiber.

  10. Modeling Cable and Guide Channel Interaction in a High-Strength Cable-Driven Continuum Manipulator

    PubMed Central

    Moses, Matthew S.; Murphy, Ryan J.; Kutzer, Michael D. M.; Armand, Mehran

    2016-01-01

    This paper presents several mechanical models of a high-strength cable-driven dexterous manipulator designed for surgical procedures. A stiffness model is presented that distinguishes between contributions from the cables and the backbone. A physics-based model incorporating cable friction is developed and its predictions are compared with experimental data. The data show that under high tension and high curvature, the shape of the manipulator deviates significantly from a circular arc. However, simple parametric models can fit the shape with good accuracy. The motivating application for this study is to develop a model so that shape can be predicted using easily measured quantities such as tension, so that real-time navigation may be performed, especially in minimally-invasive surgical procedures, while reducing the need for hazardous imaging methods such as fluoroscopy. PMID:27818607

  11. Modeling Cable and Guide Channel Interaction in a High-Strength Cable-Driven Continuum Manipulator.

    PubMed

    Moses, Matthew S; Murphy, Ryan J; Kutzer, Michael D M; Armand, Mehran

    2015-12-01

    This paper presents several mechanical models of a high-strength cable-driven dexterous manipulator designed for surgical procedures. A stiffness model is presented that distinguishes between contributions from the cables and the backbone. A physics-based model incorporating cable friction is developed and its predictions are compared with experimental data. The data show that under high tension and high curvature, the shape of the manipulator deviates significantly from a circular arc. However, simple parametric models can fit the shape with good accuracy. The motivating application for this study is to develop a model so that shape can be predicted using easily measured quantities such as tension, so that real-time navigation may be performed, especially in minimally-invasive surgical procedures, while reducing the need for hazardous imaging methods such as fluoroscopy.

  12. Wind-induced vibration of stay cables

    DOT National Transportation Integrated Search

    2007-08-01

    Cable-stayed bridges have become the form of choice over the past several decades for bridges in the medium- to long-span range. In some cases, serviceability problems involving large amplitude vibrations of stay cables under certain wind and rain co...

  13. 46 CFR 111.60-4 - Minimum cable conductor size.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Minimum cable conductor size. 111.60-4 Section 111.60-4...-GENERAL REQUIREMENTS Wiring Materials and Methods § 111.60-4 Minimum cable conductor size. Each cable conductor must be #18 AWG (0.82 mm2) or larger except— (a) Each power and lighting cable conductor must be...

  14. 46 CFR 111.60-4 - Minimum cable conductor size.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Minimum cable conductor size. 111.60-4 Section 111.60-4...-GENERAL REQUIREMENTS Wiring Materials and Methods § 111.60-4 Minimum cable conductor size. Each cable conductor must be #18 AWG (0.82 mm2) or larger except— (a) Each power and lighting cable conductor must be...

  15. Optimal energy harvesting from vortex-induced vibrations of cables

    PubMed Central

    de Langre, E.; Michelin, S.

    2016-01-01

    Vortex-induced vibrations (VIV) of flexible cables are an example of flow-induced vibrations that can act as energy harvesting systems by converting energy associated with the spontaneous cable motion into electricity. This work investigates the optimal positioning of the harvesting devices along the cable, using numerical simulations with a wake oscillator model to describe the unsteady flow forcing. Using classical gradient-based optimization, the optimal harvesting strategy is determined for the generic configuration of a flexible cable fixed at both ends, including the effect of flow forces and gravity on the cable’s geometry. The optimal strategy is found to consist systematically in a concentration of the harvesting devices at one of the cable’s ends, relying on deformation waves along the cable to carry the energy towards this harvesting site. Furthermore, we show that the performance of systems based on VIV of flexible cables is significantly more robust to flow velocity variations, in comparison with a rigid cylinder device. This results from two passive control mechanisms inherent to the cable geometry: (i) the adaptability to the flow velocity of the fundamental frequencies of cables through the flow-induced tension and (ii) the selection of successive vibration modes by the flow velocity for cables with gravity-induced tension. PMID:27956880

  16. The estimation of electrical cable fire-induced damage limits

    NASA Astrophysics Data System (ADS)

    Nowlen, S. P.; Jacobus, M. J.

    Sandia National Laboratories has, for several years, been engaged in the performance of both fire safety and electrical equipment qualification research under independent programs sponsored by the US Nuclear Regulatory Commission. Recent comparisons between electrical cable thermal damageability data gathered independently in these two efforts indicate that a direct correlation exists between certain of the recent cable thermal vulnerability information gathered under equipment qualification conditions and thermal damageability in a fire environment. This direct correlation allows for a significant expansion of the data base on estimated cable thermal vulnerability limits in a fire environment because of the wide range of cable types and products that have been evaluated as a part of the equipment qualification research. This paper provides a discussion of the basis for the derived correlation, and presents estimated cable thermal damage limits for a wide range of generic cable types and specific cable products. The supposition that a direct correlation exists is supported through direct comparisons of the test results for certain specific cable products. The proposed supplemental cable fire vulnerability data gained from examination of the equipment qualification results is presented. These results should be of particular interest to those engaged in the evaluation of fire risk for industrial facilities, including nuclear power plants.

  17. 30 CFR 57.12038 - Attachment of trailing cables.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Attachment of trailing cables. 57.12038 Section 57.12038 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Electricity Surface and Underground § 57.12038 Attachment of trailing cables. Trailing cables shall be...

  18. 47 CFR 32.6426 - Intrabuilding network cable expense.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 2 2011-10-01 2011-10-01 false Intrabuilding network cable expense. 32.6426... Intrabuilding network cable expense. (a) This account shall include expenses associated with intrabuilding network cable. (b) Subsidiary record categories shall be maintained as provided in § 32.2426(a) of subpart...

  19. 47 CFR 32.6426 - Intrabuilding network cable expense.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Intrabuilding network cable expense. 32.6426... Intrabuilding network cable expense. (a) This account shall include expenses associated with intrabuilding network cable. (b) Subsidiary record categories shall be maintained as provided in § 32.2426(a) of subpart...

  20. Dynamic characteristics of stay cables with inerter dampers

    NASA Astrophysics Data System (ADS)

    Shi, Xiang; Zhu, Songye

    2018-06-01

    This study systematically investigates the dynamic characteristics of a stay cable with an inerter damper installed close to one end of a cable. The interest in applying inerter dampers to stay cables is partially inspired by the superior damping performance of negative stiffness dampers in the same application. A comprehensive parametric study on two major parameters, namely, inertance and damping coefficients, are conducted using analytical and numerical approaches. An inerter damper can be optimized for one vibration mode of a stay cable by generating identical wave numbers in two adjacent modes. An optimal design approach is proposed for inerter dampers installed on stay cables. The corresponding optimal inertance and damping coefficients are summarized for different damper locations and interested modes. Inerter dampers can offer better damping performance than conventional viscous dampers for the target mode of a stay cable that requires optimization. However, additional damping ratios in other vibration modes through inerter damper are relatively limited.