Sample records for tanks ust out-of-service

  1. 40 CFR 281.36 - Out-of-service UST systems and closure.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 28 2013-07-01 2013-07-01 false Out-of-service UST systems and closure... § 281.36 Out-of-service UST systems and closure. In order to be considered no less stringent than the... and corrective action requirements must be complied with. (c) All UST systems taken out of service...

  2. 40 CFR 281.36 - Out-of-service UST systems and closure.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 27 2014-07-01 2014-07-01 false Out-of-service UST systems and closure... § 281.36 Out-of-service UST systems and closure. In order to be considered no less stringent than the... and corrective action requirements must be complied with. (c) All UST systems taken out of service...

  3. 40 CFR 281.36 - Out-of-service UST systems and closure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Out-of-service UST systems and closure... § 281.36 Out-of-service UST systems and closure. In order to be considered no less stringent than the... and corrective action requirements must be complied with. (c) All UST systems taken out of service...

  4. 40 CFR 281.36 - Out-of-service UST systems and closure.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Out-of-service UST systems and closure... § 281.36 Out-of-service UST systems and closure. In order to be considered no less stringent than the... and corrective action requirements must be complied with. (c) All UST systems taken out of service...

  5. 40 CFR 281.36 - Out-of-service UST systems and closure.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 28 2012-07-01 2012-07-01 false Out-of-service UST systems and closure... § 281.36 Out-of-service UST systems and closure. In order to be considered no less stringent than the... and corrective action requirements must be complied with. (c) All UST systems taken out of service...

  6. 40 CFR 280.73 - Applicability to previously closed UST systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.73 Applicability to previously closed UST systems. When directed by the implementing agency, the owner and operator of an UST system... systems. 280.73 Section 280.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID...

  7. 40 CFR 280.73 - Applicability to previously closed UST systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.73 Applicability to previously closed UST systems. When directed by the implementing agency, the owner and operator of an UST system... systems. 280.73 Section 280.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID...

  8. 40 CFR 280.73 - Applicability to previously closed UST systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.73 Applicability to previously closed UST systems. When directed by the implementing agency, the owner and operator of an UST system... systems. 280.73 Section 280.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID...

  9. 40 CFR 280.73 - Applicability to previously closed UST systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.73 Applicability to previously closed UST systems. When directed by the implementing agency, the owner and operator of an UST system... systems. 280.73 Section 280.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID...

  10. 40 CFR 280.73 - Applicability to previously closed UST systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.73 Applicability to previously closed UST systems. When directed by the implementing agency, the owner and operator of an UST system... systems. 280.73 Section 280.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID...

  11. 40 CFR 280.71 - Permanent closure and changes-in-service.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.71 Permanent closure and changes... sludges. All tanks taken out of service permanently must also be either removed from the ground or filled with an inert solid material. (c) Continued use of an UST system to store a non-regulated substance is...

  12. 40 CFR 280.71 - Permanent closure and changes-in-service.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.71 Permanent closure and changes... sludges. All tanks taken out of service permanently must also be either removed from the ground or filled with an inert solid material. (c) Continued use of an UST system to store a non-regulated substance is...

  13. 40 CFR 280.71 - Permanent closure and changes-in-service.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.71 Permanent closure and changes... sludges. All tanks taken out of service permanently must also be either removed from the ground or filled with an inert solid material. (c) Continued use of an UST system to store a non-regulated substance is...

  14. 40 CFR 280.71 - Permanent closure and changes-in-service.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.71 Permanent closure and changes... sludges. All tanks taken out of service permanently must also be either removed from the ground or filled with an inert solid material. (c) Continued use of an UST system to store a non-regulated substance is...

  15. UST/LUST Program Information

    EPA Pesticide Factsheets

    This asset includes an inventory of programmatic information, including policies and guidance, training course materials and Leaking Underground Storage Tanks (LUST) Trust Fund information. This documentation is used by states, territories, tribes and private parties to implement the Underground Storage Tank (UST) program. It also includes analysis of the laws and regulations that govern USTs, and policies and guidance for implementing the UST program developed by EPA in consultation with state and territorial UST programs.

  16. RCRA/UST, superfund, and EPCRA hotline training module. Introduction to: RCRA subtitle I. Underground storage tanks (40 cfr part 280). Updated as of July 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-07-01

    This module explains the Underground Storage Tank Regulatory Program established in 1988, that includes technical requirements to prevent, protect, and clean up releases from Underground Storage Tanks (USTs), as well as financial responsibility requirements to guarantee that UST owners and operators have enough money set aside to clean up releases and compensate third parties. Describes the Universe of USTs and the technical and financial requirements that apply to them. Defines underground storage tank and provides criteria for determining which USTs are subject to regulation. Discusses deadlines for upgrading tanks and the closure and corrective action requirements.

  17. 40 CFR 280.41 - Requirements for petroleum UST systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Requirements for petroleum UST systems... UNDERGROUND STORAGE TANKS (UST) Release Detection § 280.41 Requirements for petroleum UST systems. Owners and operators of petroleum UST systems must provide release detection for tanks and piping as follows: (a) Tanks...

  18. 40 CFR 280.41 - Requirements for petroleum UST systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Requirements for petroleum UST systems... UNDERGROUND STORAGE TANKS (UST) Release Detection § 280.41 Requirements for petroleum UST systems. Owners and operators of petroleum UST systems must provide release detection for tanks and piping as follows: (a) Tanks...

  19. Permanent Closure of MFC Biodiesel Underground Storage Tank 99ANL00013

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kerry L. Nisson

    2012-10-01

    This closure package documents the site assessment and permanent closure of the Materials and Fuels Complex biodiesel underground storage tank 99ANL00013 in accordance with the regulatory requirements established in 40 CFR 280.71, “Technical Standards and Corrective Action Requirements for Owners and Operators of Underground Storage Tanks: Out-of-Service UST Systems and Closure.”

  20. 40 CFR 280.21 - Upgrading of existing UST systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 28 2013-07-01 2013-07-01 false Upgrading of existing UST systems. 280.21 Section 280.21 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES... STORAGE TANKS (UST) UST Systems: Design, Construction, Installation and Notification § 280.21 Upgrading of...

  1. 40 CFR 280.21 - Upgrading of existing UST systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 27 2014-07-01 2014-07-01 false Upgrading of existing UST systems. 280.21 Section 280.21 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES... STORAGE TANKS (UST) UST Systems: Design, Construction, Installation and Notification § 280.21 Upgrading of...

  2. 40 CFR 280.21 - Upgrading of existing UST systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 28 2012-07-01 2012-07-01 false Upgrading of existing UST systems. 280.21 Section 280.21 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES... STORAGE TANKS (UST) UST Systems: Design, Construction, Installation and Notification § 280.21 Upgrading of...

  3. 40 CFR 280.230 - Operating an underground storage tank or underground storage tank system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... underground storage tank or underground storage tank system. (a) Operating an UST or UST system prior to...) Operating an UST or UST system after foreclosure. The following provisions apply to a holder who, through..., the purchaser must decide whether to operate or close the UST or UST system in accordance with...

  4. 40 CFR 280.230 - Operating an underground storage tank or underground storage tank system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... underground storage tank or underground storage tank system. (a) Operating an UST or UST system prior to...) Operating an UST or UST system after foreclosure. The following provisions apply to a holder who, through..., the purchaser must decide whether to operate or close the UST or UST system in accordance with...

  5. 40 CFR 280.230 - Operating an underground storage tank or underground storage tank system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... underground storage tank or underground storage tank system. (a) Operating an UST or UST system prior to...) Operating an UST or UST system after foreclosure. The following provisions apply to a holder who, through..., the purchaser must decide whether to operate or close the UST or UST system in accordance with...

  6. 40 CFR 280.230 - Operating an underground storage tank or underground storage tank system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... underground storage tank or underground storage tank system. (a) Operating an UST or UST system prior to...) Operating an UST or UST system after foreclosure. The following provisions apply to a holder who, through..., the purchaser must decide whether to operate or close the UST or UST system in accordance with...

  7. 40 CFR 280.230 - Operating an underground storage tank or underground storage tank system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... underground storage tank or underground storage tank system. (a) Operating an UST or UST system prior to...) Operating an UST or UST system after foreclosure. The following provisions apply to a holder who, through..., the purchaser must decide whether to operate or close the UST or UST system in accordance with...

  8. Underground storage tank management plan, Oak Ridge Y-12 Plant, Oak Ridge, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-09-01

    The Underground Storage Tank (UST) Program at the Oak Ridge Y-12 Plant was established to locate UST systems at the facility and to ensure that all operating UST systems are free of leaks. UST systems have been removed or upgraded in accordance with Tennessee Department of Environment and Conservation (TDEC) regulations and guidance. With the closure of a significant portion of the USTs, the continuing mission of the UST Management Program is to manage the remaining active UST systems and continue corrective actions in a safe regulatory compliant manner. This Program outlines the compliance issues that must be addressed, reviewsmore » the current UST inventory and compliance approach, and presents the status and planned activities associated with each UST system. The UST Program provides guidance for implementing TDEC regulations and guidelines for petroleum UST systems. The plan is divided into three major sections: (1) regulatory requirements, (2) active UST sites, and (3) out-of-service UST sites. These sections describe in detail the applicable regulatory drivers, the UST sites addressed under the Program, and the procedures and guidance for compliance.« less

  9. UST Financial Assurance Information

    EPA Pesticide Factsheets

    Subtitle I of the Resource Conservation and Recovery Act, as amended by the Hazardous Waste Disposal Act of 1984, brought underground storage tanks (USTs) under federal regulation. As part of that regulation, Congress directed EPA to develop financial responsibility regulations for UST owners and operators. Congress wanted owners and operators of underground storage tanks (USTs) to show that they have the financial resources to clean up a site if a release occurs, correct environmental damage, and compensate third parties for injury to their property or themselves.Owners and operators have several options: obtain insurance coverage from an insurer or a risk retention group; demonstrate self-insurance using a financial test; obtain corporate guarantees, surety bonds, or letters of credit; place the required amount into a trust fund administered by a third party; or rely on coverage provided by a state financial assurance fund.Information in this data asset includes state documentation to support this requirement. Many states have developed financial assurance funds to help owners and operators meet financial responsibility requirements and to help cover the costs of cleanups. State financial assurance fund programs, which supplement or are a substitute for private insurance, have been especially useful for small-to-medium sized petroleum marketers.EPA requires its Regional Offices to conduct annual reviews of state financial assurance funds. Data is provided by s

  10. 40 CFR 280.74 - Closure records.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... following ways: (a) By the owners and operators who took the UST system out of service; (b) By the current... STANDARDS AND CORRECTIVE ACTION REQUIREMENTS FOR OWNERS AND OPERATORS OF UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.74 Closure records. Owners and operators must maintain...

  11. 40 CFR 280.74 - Closure records.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... following ways: (a) By the owners and operators who took the UST system out of service; (b) By the current... STANDARDS AND CORRECTIVE ACTION REQUIREMENTS FOR OWNERS AND OPERATORS OF UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.74 Closure records. Owners and operators must maintain...

  12. 40 CFR 280.74 - Closure records.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... following ways: (a) By the owners and operators who took the UST system out of service; (b) By the current... STANDARDS AND CORRECTIVE ACTION REQUIREMENTS FOR OWNERS AND OPERATORS OF UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.74 Closure records. Owners and operators must maintain...

  13. 40 CFR 280.74 - Closure records.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... following ways: (a) By the owners and operators who took the UST system out of service; (b) By the current... STANDARDS AND CORRECTIVE ACTION REQUIREMENTS FOR OWNERS AND OPERATORS OF UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.74 Closure records. Owners and operators must maintain...

  14. 40 CFR 280.74 - Closure records.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... following ways: (a) By the owners and operators who took the UST system out of service; (b) By the current... STANDARDS AND CORRECTIVE ACTION REQUIREMENTS FOR OWNERS AND OPERATORS OF UNDERGROUND STORAGE TANKS (UST) Out-of-Service UST Systems and Closure § 280.74 Closure records. Owners and operators must maintain...

  15. 40 CFR 281.30 - New UST system design, construction, installation, and notification.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 27 2011-07-01 2011-07-01 false New UST system design, construction, installation, and notification. 281.30 Section 281.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) APPROVAL OF STATE UNDERGROUND STORAGE TANK PROGRAMS Criteria for No-Less-Stringent § 281.30 New UST...

  16. 40 CFR 281.30 - New UST system design, construction, installation, and notification.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false New UST system design, construction, installation, and notification. 281.30 Section 281.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) APPROVAL OF STATE UNDERGROUND STORAGE TANK PROGRAMS Criteria for No-Less-Stringent § 281.30 New UST...

  17. Class A and Class B UST Operator Exams

    EPA Pesticide Factsheets

    Learn about exams developed by EPA to help underground storage tank system owners and operators in Indian country meet the 2015 federal UST regulation requirement that designated operators demonstrate knowledge and pass an exam.

  18. CHEMICALS STORED IN USTS: CHARACTERISTICS AND LEAK DETECTION

    EPA Science Inventory

    The regulations Issued by the U.S. Environmental Protection Agency (EPA) In 1988 require, with several exceptions, that the Integrity of underground storage tank (UST) systems containing petroleum fuels and hazardous chemicals be routinely tested. The regulatory standards for ...

  19. Think Tank.

    ERIC Educational Resources Information Center

    Governick, Heather; Wellington, Thom

    1998-01-01

    Examines the options for upgrading, replacing, and removal or closure of underground storage tanks (UST). Reveals the diverse regulatory control involving USTs, the Environmental Protection Agency's interest in pursuing violators, and stresses the need for administrators to be knowledgeable about state and local agency definitions of regulated…

  20. EPA Uses Greener Cleanup Practices to Reduce Environmental Footprint at Telles Ranch UST Site, Colorado River Indian Tribes Reservation

    EPA Pesticide Factsheets

    Learn about the work of EPA’s Pacific Southwest Underground Storage Tank (UST) program to reduce its environmental footprint by using greener cleanup practices at the Telles Ranch leaking UST site in Arizona.

  1. ASSESSING UST CORRECTIVE ACTION TECHNOLOGIES: IN SITU SVE-BASED SYSTEMS FOR FREE PRODUCT RECOVERY AND RESIDUAL HYDROCARBON REMOVAL

    EPA Science Inventory

    The number of confirmed releases of petroleum products from underground storage tank (UST) systems has increased significantly since promulgation of the final UST regulations by the U.S. Environmental Protection Agency in December 1988. This increase has outpaced the resources of...

  2. 76 FR 46798 - Compatibility of Underground Storage Tank Systems With Biofuel Blends; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-03

    ... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-UST-2010-0651; FRL-9447-3] Compatibility of Underground Storage Tank Systems With Biofuel Blends; Correction AGENCY: Environmental Protection Agency (EPA). ACTION... of underground storage tanks (USTs) can demonstrate compliance with the Federal compatibility...

  3. Environmental projects. Volume 2: Underground storage tanks compliance program

    NASA Technical Reports Server (NTRS)

    Kushner, L.

    1987-01-01

    Six large parabolic dish antennas are located at the Goldstone Deep Space Communications Complex north of Barstow, California. As a large-scale facility located in a remote, isolated desert region, the GDSCC operations require numerous on-site storage facilities for gasoline, diesel and hydraulic oil. These essential fluids are stored in underground storage tanks (USTs). Because USTs may develop leaks with the resultant seepage of their hazardous contents into the surrounding soil, local, State and Federal authorities have adopted stringent regulations for the testing and maintenance of USTs. Under the supervision of JPL's Office of Telecommunications and Data Acquisition, a year-long program has brought 27 USTs at the Goldstone Complex into compliance with Federal, State of California and County of San Bernadino regulations. Of these 27 USTs, 15 are operating today, 11 have been temporary closed down, and 1 abandoned in place. In 1989, the 15 USTs now operating at the Goldstone DSCC will be replaced either by modern, double-walled USTs equipped with automatic sensors for leak detection, or by above ground storage tanks. The 11 inactivated USTs are to be excavated, removed and disposed of according to regulation.

  4. Underground storage tank management plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1994-09-01

    The Underground Storage Tank (UST) Management Program at the Oak Ridge Y-12 Plant was established to locate UST systems in operation at the facility, to ensure that all operating UST systems are free of leaks, and to establish a program for the removal of unnecessary UST systems and upgrade of UST systems that continue to be needed. The program implements an integrated approach to the management of UST systems, with each system evaluated against the same requirements and regulations. A common approach is employed, in accordance with Tennessee Department of Environment and Conservation (TDEC) regulations and guidance, when corrective actionmore » is mandated. This Management Plan outlines the compliance issues that must be addressed by the UST Management Program, reviews the current UST inventory and compliance approach, and presents the status and planned activities associated with each UST system. The UST Management Plan provides guidance for implementing TDEC regulations and guidelines for petroleum UST systems. (There are no underground radioactive waste UST systems located at Y-12.) The plan is divided into four major sections: (1) regulatory requirements, (2) implementation requirements, (3) Y-12 Plant UST Program inventory sites, and (4) UST waste management practices. These sections describe in detail the applicable regulatory drivers, the UST sites addressed under the Management Program, and the procedures and guidance used for compliance with applicable regulations.« less

  5. 76 FR 21299 - Oregon: Tentative Approval of State Underground Storage Tank Program: Public Hearing Cancellation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-15

    ... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 281 [EPA-R10-UST-2011-0097; FRL-9296-1] Oregon: Tentative Approval of State Underground Storage Tank Program: Public Hearing Cancellation AGENCY... application for final approval of its Underground Storage Tank (UST) Program under Subtitle I of the Resource...

  6. Vertical Profiling of Soil Vapor Concentrations Using a New Passive Diffusion Sampler at a UST Site

    EPA Science Inventory

    Understanding the transport of volatile contaminants in soil gas, particularly those associated with underground storage tanks (USTs), requires a detailed knowledge about the depth-dependent distribution of chemical species in the subsurface. Traditional monitoring wells generall...

  7. Leaking Underground Storage Tank (LUST) Trust Fund

    EPA Pesticide Factsheets

    In 1986, Congress created the Leaking Underground Storage Tank (LUST) Trust Fund to address releases from federally regulated underground storage tanks (USTs) by amending Subtitle I of the Solid Waste Disposal Act.

  8. MEASUREMENT AND ANALYSIS OF VAPOR SENSORS USED AT UNDERGROUND STORAGE TANK SITES

    EPA Science Inventory

    This report is a continuation of an investigation to quantify the operating characteristics of vapor sensor technologies used at underground storage tank (UST) sites. n the previous study (EPA/600/R-92/219) the sensitivity, selectivity, and response time to simulated UST environm...

  9. A New Passive Diffusion Sampler for Improving the Calibration of Models to Evaluate Vapor Movement at UST Sites

    EPA Science Inventory

    Understanding transport of volatile contaminants in soil gas and ground water, particularly those associated with underground storage tanks (USTs), requires a detailed knowledge about the depthdependent distribution of chemical species in the subsurface. A risk assessment of the...

  10. Guidance on Compatibility of UST Systems with Ethanol Blends Greater Than 10 Percent and Biodiesel Blends Greater Than 20 Percent

    EPA Pesticide Factsheets

    EPA guidance on complying with the federal compatibility requirement for underground storage tank (UST) systems storing gasoline containing greater than 10 percent ethanol or diesel containing greater than 20 percent biodiesel.

  11. Environmental projects. Volume 13: Underground storage tanks, removal and replacement. Goldstone Deep Space Communications Complex

    NASA Technical Reports Server (NTRS)

    Bengelsdorf, Irv

    1991-01-01

    The Goldstone Deep Space Communications Complex (GDSCC), located in the Mojave Desert about 40 miles north of Barstow, California, and about 160 miles northeast of Pasadena, is part of the National Aeronautics and Space Administration's (NASA's) Deep Space Network, one of the world's largest and most sensitive scientific telecommunications and radio navigation networks. Activities at the GDSCC are carried out in support of six large parabolic dish antennas. As a large-scale facility located in a remote, isolated desert region, the GDSCC operations require numerous on-site storage facilities for gasoline, diesel oil, hydraulic oil, and waste oil. These fluids are stored in underground storage tanks (USTs). This present volume describes what happened to the 26 USTs that remained at the GDSCC. Twenty-four of these USTs were constructed of carbon steel without any coating for corrosion protection, and without secondary containment or leak detection. Two remaining USTs were constructed of fiberglass-coated carbon steel but without secondary containment or leak protection. Of the 26 USTs that remained at the GDSCC, 23 were cleaned, removed from the ground, cut up, and hauled away from the GDSCC for environmentally acceptable disposal. Three USTs were permanently closed (abandoned in place).

  12. 40 CFR 280.43 - Methods of release detection for tanks.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... two consecutive stick readings at both the beginning and ending of the period; (3) The equipment used... UNDERGROUND STORAGE TANKS (UST) Release Detection § 280.43 Methods of release detection for tanks. Each method... of the tank is made to the nearest one-eighth of an inch at least once a month. Note: Practices...

  13. 40 CFR 280.43 - Methods of release detection for tanks.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... two consecutive stick readings at both the beginning and ending of the period; (3) The equipment used... UNDERGROUND STORAGE TANKS (UST) Release Detection § 280.43 Methods of release detection for tanks. Each method... of the tank is made to the nearest one-eighth of an inch at least once a month. Note: Practices...

  14. Underground Storage Tanks on Indian Lands. Education Moderates an Environmental Threat.

    ERIC Educational Resources Information Center

    Hillger, Robert W.; Small, Matthew C.

    1992-01-01

    Describes problems related to old underground storage tanks (USTs) that may leak toxic contents, focusing on relevance for American Indian reservations. Discusses design, installation, and upgrading of UST systems; federal definitions and regulations; leak detection; legal responsibility; and education for public awareness. Includes Environmental…

  15. Evaluation of a New Passive Diffusion Sampler for Improving the Calibration of Models to Evaluate Vapor Movement at UST Sites

    EPA Science Inventory

    Understanding transport of volatile contaminants in soil gas and ground water, particularly those associated with underground storage tanks (USTs), requires a detailed knowledge about the depth-dependent distribution of chemical species in the subsurface. A risk assessment of th...

  16. VOLUMETRIC LEAK DETECTION IN LARGE UNDERGROUND STORAGE TANKS - VOLUME I

    EPA Science Inventory

    A set of experiments was conducted to determine whether volumetric leak detection system presently used to test underground storage tanks (USTs) up to 38,000 L (10,000 gal) in capacity could meet EPA's regulatory standards for tank tightness and automatic tank gauging systems whe...

  17. Fuel Storage Tanks at FAA Facilities: Order 1050.15A

    DOT National Transportation Integrated Search

    1997-04-30

    The Federal Aviation Administration (FAA) has over 4,000 fuel storage tanks (FST) in its : inventory. Most of these FSTs are underground storage tanks (UST) that contain fuel for : emergency backup generators providing secondary power to air navigati...

  18. UST System Compatibility with Petroleum-Biofuel Blends: A Brief Guide to the 2015 Federal UST Regulations for Owners and Operators of USTs Located on Tribal Lands

    EPA Pesticide Factsheets

    Review information for UST owners and operators on tribal lands with compatibility requirements in the 2015 federal UST regulation when storing gasoline blends containing greater than 10 percent ethanol or diesel blends containing greater than 20 percent.

  19. 100-N Area underground storage tank closures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rowley, C.A.

    1993-08-01

    This report describes the removal/characterization actions concerning underground storage tanks (UST) at the 100-N Area. Included are 105-N-LFT, 182-N-1-DT, 182-N-2-DT, 182-N-3-DT, 100-N-SS-27, and 100-N-SS-28. The text of this report gives a summary of remedial activities. In addition, correspondence relating to UST closures can be found in Appendix B. Appendix C contains copies of Unusual Occurrence Reports, and validated sampling data results comprise Appendix D.

  20. Review of sensors for the in situ chemical characterization of the Hanford underground storage tanks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kyle, K.R.; Mayes, E.L.

    1994-07-29

    Lawrence Livermore National Laboratory (LLNL), in the Technical Task Plan (TTP) SF-2112-03 subtask 2, is responsible for the conceptual design of a Raman probe for inclusion in the in-tank cone penetrometer. As part of this task, LLNL is assigned the further responsibility of generating a report describing a review of sensor technologies other than Raman that can be incorporated in the in-tank cone penetrometer for the chemical analysis of the tank environment. These sensors would complement the capabilities of the Raman probe, and would give information on gaseous, liquid, and solid state species that are insensitive to Raman interrogation. Thismore » work is part of a joint effort involving several DOE laboratories for the design and development of in-tank cone penetrometer deployable systems for direct UST waste characterization at Westinghouse Hanford Company (WHC) under the auspices of the U.S. Department of Energy (DOE) Underground Storage Tank Integrated Demonstration (UST-ID).« less

  1. Fuel storage tanks at FAA facilities : Order 1050.15A : executive summary.

    DOT National Transportation Integrated Search

    1997-04-30

    The Federal Aviation Administration (FAA) has over 4,000 fuel storage tanks (FST) in its inventory. Most of these FSTs are underground storage tanks (UST) that contain fuel for emergency backup generators providing secondary power to air navigational...

  2. Energy Policy Act of 2005 and Underground Storage Tanks (USTs)

    EPA Pesticide Factsheets

    The Energy Policy Act of 2005 significantly affected federal and state underground storage tank programs, required major changes to the programs, and is aimed at reducing underground storage tank releases to our environment.

  3. State and Territorial Underground Storage Tank Regulations: Compliance Deadlines for Major Provisions

    EPA Pesticide Factsheets

    Review compliance deadlines for major provisions of the 2015 federal UST requirements, in the 15 states that have updated their state underground storage tank regulations to incorporate the revised requirements.

  4. Environmental Assessment: Proposed Construction of Army and Air Force Exchange Service New Day Street Shoppette

    DTIC Science & Technology

    2003-10-01

    would either be operated by AAFES as a franchise or would be owned by AAFES. The three existing 10,000-gallon underground storage tanks (USTs...Street Shoppette FINAL Army and Air Force Exchange Service 2-3 The restaurant would either be operated by AAFES as a franchise or would be owned by...levels of employment with the inclusion of a new restaurant, (to be either a franchise or AAFES-owned), car wash, increased services of the Auto Pride

  5. HOW TO EFFECTIVELY RECOVER FREE PRODUCT AT LEAKING UNDERGROUND STORAGE TANK SITES - A GUIDE FOR STATE REGULATORS

    EPA Science Inventory

    Over 315,000 releases from leaking underground storage tanks (USTs) were reported by state and local environmental agencies as of March 19961. EPA's Office of Underground Storage Tanks (OUST) anticipates that at least 100,000 additional releases will be confirmed in the next few ...

  6. Technical Guide for Addressing Petroleum Vapor Intrusion at Leaking Underground Storage Tank Sites

    EPA Pesticide Factsheets

    Review technical information for personnel EPA and implementing agencies for investigating and assessing petroleum vapor intrusion (PVI) at sites where petroleum hydrocarbons (PHCs) have been released from underground storage tanks (USTs).

  7. 18 CFR 1304.403 - Marina sewage pump-out stations and holding tanks.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 2 2011-04-01 2011-04-01 false Marina sewage pump-out... OTHER ALTERATIONS Miscellaneous § 1304.403 Marina sewage pump-out stations and holding tanks. All pump... operating requirements: (a) Spill-proof connection with shipboard holding tanks; (b) Suction controls or...

  8. 18 CFR 1304.403 - Marina sewage pump-out stations and holding tanks.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 18 Conservation of Power and Water Resources 2 2012-04-01 2012-04-01 false Marina sewage pump-out... OTHER ALTERATIONS Miscellaneous § 1304.403 Marina sewage pump-out stations and holding tanks. All pump... operating requirements: (a) Spill-proof connection with shipboard holding tanks; (b) Suction controls or...

  9. 18 CFR 1304.403 - Marina sewage pump-out stations and holding tanks.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 18 Conservation of Power and Water Resources 2 2013-04-01 2012-04-01 true Marina sewage pump-out... OTHER ALTERATIONS Miscellaneous § 1304.403 Marina sewage pump-out stations and holding tanks. All pump... operating requirements: (a) Spill-proof connection with shipboard holding tanks; (b) Suction controls or...

  10. 18 CFR 1304.403 - Marina sewage pump-out stations and holding tanks.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 2 2014-04-01 2014-04-01 false Marina sewage pump-out... OTHER ALTERATIONS Miscellaneous § 1304.403 Marina sewage pump-out stations and holding tanks. All pump... operating requirements: (a) Spill-proof connection with shipboard holding tanks; (b) Suction controls or...

  11. 18 CFR 1304.403 - Marina sewage pump-out stations and holding tanks.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... stations and holding tanks. 1304.403 Section 1304.403 Conservation of Power and Water Resources TENNESSEE... OTHER ALTERATIONS Miscellaneous § 1304.403 Marina sewage pump-out stations and holding tanks. All pump... operating requirements: (a) Spill-proof connection with shipboard holding tanks; (b) Suction controls or...

  12. 40 CFR 280.11 - Interim prohibition for deferred UST systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Will prevent releases due to corrosion or structural failure for the operational life of the UST system; (2) Is cathodically protected against corrosion, constructed of noncorrodible material, steel clad... substance. (b) Notwithstanding paragraph (a) of this section, an UST system without corrosion protection may...

  13. 40 CFR 280.11 - Interim prohibition for deferred UST systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Will prevent releases due to corrosion or structural failure for the operational life of the UST system; (2) Is cathodically protected against corrosion, constructed of noncorrodible material, steel clad... substance. (b) Notwithstanding paragraph (a) of this section, an UST system without corrosion protection may...

  14. 40 CFR 280.11 - Interim prohibition for deferred UST systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Will prevent releases due to corrosion or structural failure for the operational life of the UST system; (2) Is cathodically protected against corrosion, constructed of noncorrodible material, steel clad... substance. (b) Notwithstanding paragraph (a) of this section, an UST system without corrosion protection may...

  15. 40 CFR 280.11 - Interim prohibition for deferred UST systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Will prevent releases due to corrosion or structural failure for the operational life of the UST system; (2) Is cathodically protected against corrosion, constructed of noncorrodible material, steel clad... substance. (b) Notwithstanding paragraph (a) of this section, an UST system without corrosion protection may...

  16. 40 CFR 280.11 - Interim prohibition for deferred UST systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Will prevent releases due to corrosion or structural failure for the operational life of the UST system; (2) Is cathodically protected against corrosion, constructed of noncorrodible material, steel clad... substance. (b) Notwithstanding paragraph (a) of this section, an UST system without corrosion protection may...

  17. Shop fabricated corrosion-resistant underground storage tanks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geyer, W.B.; Stellmach, W.A.

    1995-12-31

    Integral corrosion resistance has long been incorporated into shop fabricated steel underground storage tank design. Since 1969, an industry standard has been the sti-P{sub 3}{reg_sign} (P3) tank. However, the past decade has seen the development of several alternative corrosion resistant and secondary containment technologies. Fiberglass-coated steel composite tanks, and jacketed tanks utilizing various materials as a secondary wall, provide corrosion resistance without the cathodic protection monitoring requirements mandated by the EPA for single-wall P3 tanks. On the other hand, the P3 tank is the only tank technology commonly marketed today with an integral ability to verify its corrosion resistance overmore » the life of the tank. Many existing USTs remain to be replaced or upgraded with corrosion resistance (and other requirements) by the end of 1998. Steel tanks built and installed prior to the advent of pre-engineered, factory-supplied protection against corrosion can be retrofitted with cathodic protection or can be internally lined. Specific installation standards developed by the steel tank industry and the petroleum industry must be followed so as to assure the integrity of the various corrosion resistant technologies developed by the Steel Tank Institute. The technologies describes in this paper will ensure compliance with the corrosion protection requirements of new storage tanks.« less

  18. 40 CFR 281.37 - Financial responsibility for UST systems containing petroleum.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... systems containing petroleum. 281.37 Section 281.37 Protection of Environment ENVIRONMENTAL PROTECTION... for No-Less-Stringent § 281.37 Financial responsibility for UST systems containing petroleum. (a) In... UST systems containing petroleum, the state requirements for financial responsibility for petroleum...

  19. 40 CFR 281.37 - Financial responsibility for UST systems containing petroleum.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Financial responsibility for UST... for No-Less-Stringent § 281.37 Financial responsibility for UST systems containing petroleum. (a) In order to be considered no less stringent than the federal requirements for financial responsibility for...

  20. 40 CFR 280.70 - Temporary closure.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (UST) Out-of-Service UST Systems and Closure § 280.70 Temporary closure. (a) When an UST system is... the UST system is empty. The UST system is empty when all materials have been removed using commonly... the total capacity of the UST system, remain in the system. (b) When an UST system is temporarily...

  1. 40 CFR 280.70 - Temporary closure.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (UST) Out-of-Service UST Systems and Closure § 280.70 Temporary closure. (a) When an UST system is... the UST system is empty. The UST system is empty when all materials have been removed using commonly... the total capacity of the UST system, remain in the system. (b) When an UST system is temporarily...

  2. 40 CFR 280.70 - Temporary closure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (UST) Out-of-Service UST Systems and Closure § 280.70 Temporary closure. (a) When an UST system is... the UST system is empty. The UST system is empty when all materials have been removed using commonly... the total capacity of the UST system, remain in the system. (b) When an UST system is temporarily...

  3. 40 CFR 280.70 - Temporary closure.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (UST) Out-of-Service UST Systems and Closure § 280.70 Temporary closure. (a) When an UST system is... the UST system is empty. The UST system is empty when all materials have been removed using commonly... the total capacity of the UST system, remain in the system. (b) When an UST system is temporarily...

  4. 40 CFR 280.70 - Temporary closure.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (UST) Out-of-Service UST Systems and Closure § 280.70 Temporary closure. (a) When an UST system is... the UST system is empty. The UST system is empty when all materials have been removed using commonly... the total capacity of the UST system, remain in the system. (b) When an UST system is temporarily...

  5. Artist's concept of oxygen tanks of the Apollo 14 spacecraft

    NASA Image and Video Library

    1971-01-12

    S71-16745 (January 1971) --- An artist's concept illustrating a cutaway view of one of the three oxygen tanks of the Apollo 14 spacecraft. This is the new Apollo oxygen tank design, developed since the Apollo 13 oxygen tank explosion. Apollo 14 has three oxygen tanks redesigned to eliminate ignition sources, minimize the use of combustible materials, and simplify the fabrication process. The third tank has been added to the Apollo 14 Service Module, located in the SM's sector one, apart from the pair of oxygen tanks in sector four. Arrows point out various features of the oxygen tank.

  6. In-service Inspection of Radioactive Waste Tanks at the Savannah River Site – 15410

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiersma, Bruce; Maryak, Matthew; Baxter, Lindsay

    2015-01-12

    Liquid radioactive wastes from the Savannah River Site (SRS) separation process are stored in large underground carbon steel tanks. The high level wastes are processed in several of the tanks and then transferred by piping to other site facilities for further processing before they are stabilized in a vitrified or grout waste form. Based on waste removal and processing schedules, many of the tanks will be required to be in service for times exceeding the initial intended life. Until the waste is removed from storage, transferred, and processed, the materials and structures of the tanks must maintain a confinement functionmore » by providing a barrier to the environment and by maintaining acceptable structural stability during design basis events, which include loadings from both normal service and abnormal (e.g., earthquake) conditions. A structural integrity program is in place to maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. In-service inspection (ISI) is an essential element of a comprehensive structural integrity program for the waste tanks at the Savannah River Site (SRS). The ISI program was developed to determine the degree of degradation the waste tanks have experienced due to service conditions. As a result of the inspections, an assessment can be made of the effectiveness of corrosion controls for the waste chemistry, which precludes accelerated localized and general corrosion of the waste tanks. Ultrasonic inspections (UT) are performed to detect and quantify the degree of general wall thinning, pitting and cracking as a measure of tank degradation. The results from these inspections through 2013, for the 27 Type III/IIIA tanks, indicate no reportable in-service corrosion degradation in the primary tank (i.e., general, pitting, or cracking). The average wall thickness for all tanks remains above the manufactured nominal thickness minus 0.25 millimeter and the largest pit identified is

  7. Hazardous Waste Cleanup: Industrial Oil Tank Services, Inc. in Verona, New York

    EPA Pesticide Factsheets

    Industrial Oil Tank Services, Inc. operated as a petroleum recovery facility in the town of Verona in Oneida County from mid-1970’s through 1992. The site stored hazardous wastes in 23 steel tanks of various sizes with a total combined capacity of

  8. Environmental Assessment: Waste Tank Safety Program, Hanford Site, Richland, Washington

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-02-01

    The US Department of Energy (DOE) needs to take action in the near-term, to accelerate resolution of waste tank safety issues at the Hanford Site near the City of Richland, Washington, and reduce the risks associated with operations and management of the waste tanks. The DOE has conducted nuclear waste management operations at the Hanford Site for nearly 50 years. Operations have included storage of high-level nuclear waste in 177 underground storage tanks (UST), both in single-shell tank (SST) and double-shell tank configurations. Many of the tanks, and the equipment needed to operate them, are deteriorated. Sixty-seven SSTs are presumedmore » to have leaked a total approximately 3,800,000 liters (1 million gallons) of radioactive waste to the soil. Safety issues associated with the waste have been identified, and include (1) flammable gas generation and episodic release; (2) ferrocyanide-containing wastes; (3) a floating organic solvent layer in Tank 241-C-103; (4) nuclear criticality; (5) toxic vapors; (6) infrastructure upgrades; and (7) interim stabilization of SSTs. Initial actions have been taken in all of these areas; however, much work remains before a full understanding of the tank waste behavior is achieved. The DOE needs to accelerate the resolution of tank safety concerns to reduce the risk of an unanticipated radioactive or chemical release to the environment, while continuing to manage the wastes safely.« less

  9. Magnetite-apatite-dolomitic rocks of Ust-Chulman (Aldan shield, Russia): Seligdar-type carbonatites?

    NASA Astrophysics Data System (ADS)

    Prokopyev, Ilya R.; Doroshkevich, Anna G.; Redina, Anna A.; Obukhov, Andrey V.

    2018-04-01

    The Ust-Chulman apatite ore body is situated within the Nimnyrskaya apatite zone at the Aldan shield in Russia. The latest data confirm the carbonatitic origin of the Seligdar apatite deposit (Prokopyev et al. in Ore Geol Rev 81:296-308, 2017). The results of our investigations demonstrate that the magnetite-apatite-dolomitic rocks of the Ust-Chulman are highly similar to Seligdar-type dolomitic carbonatites in terms of the mineralogy and the fluid regime of formation. The ilmenite and spinel mineral phases occur as solid solutions with magnetite, and support the magmatic origin of the Ust-Chulman ores. The chemical composition of REE- and SO3-bearing apatite crystals and, specifically, monazite-(Ce) mineralisation and the formation of Nb-rutile, late hydrothermal sulphate minerals (barite, anhydrite) and haematite are typical for carbonatite complexes. The fluid inclusions study revealed similarities to the evolutionary trend of the Seligdar carbonatites that included changes of the hydrothermal solutions from highly concentrated chloride to medium-low concentrated chloride-sulphate and oxidized carbonate-ferrous.

  10. The Dual Function of "usted:" Forms of Address in Bogota, Colombia.

    ERIC Educational Resources Information Center

    Uber, Diane Ringer

    1985-01-01

    Shows that "usted" has two functions: showing lack of solidarity and showing extreme solidarity, with "tu" falling somewhere in between on the continuum. Discusses the increasing use of "tu," especially among younger people, and presents some possible reasons for this. (SED)

  11. Installation restoration program. Closure assessment report for UST removals at sites 4 and 5 - petroleum, oils, and lubricants facility. Virginia Air National Guard, 192nd Fighter Group, Richmond International Airport, Sandston, Virginia. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The objectives of the closure assessment were to determine the extent of contaminated soil adjacent to the USTs requiring excavation, to provide documentation of soil and groundwater conditions following excavation, and to document closure activities in accordance with applicable VADEQ regulations. During closure activities, ASI provided technical support to the Base to ensure that the UST removal contractor (E K, Inc.) hereinafter referred to as the Contractor was in compliance with the technical requirements (as specified in the Plans and Specifications for Removal of Abandoned Underground Storage Tanks, Virginia Air National Guard, Richmond International Airport, Sandston, VA., dated July 1991more » and revised April 1992, and Addendum Numbers 1 through 7) of the contract. ASI was also responsible for collecting soil and/or groundwater closure samples from the excavations, and providing off-site fixed based laboratory analysis to verify clean conditions within the excavations.« less

  12. 40 CFR 280.10 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... operational purposes such as hydraulic lift tanks and electrical equipment tanks. (4) Any UST system whose... are regulated under the Atomic Energy Act of 1954 (42 U.S.C. 2011 and following); (3) Any UST system...

  13. 40 CFR 280.10 - Applicability.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... operational purposes such as hydraulic lift tanks and electrical equipment tanks. (4) Any UST system whose... are regulated under the Atomic Energy Act of 1954 (42 U.S.C. 2011 and following); (3) Any UST system...

  14. 40 CFR 280.10 - Applicability.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... operational purposes such as hydraulic lift tanks and electrical equipment tanks. (4) Any UST system whose... are regulated under the Atomic Energy Act of 1954 (42 U.S.C. 2011 and following); (3) Any UST system...

  15. 40 CFR 280.10 - Applicability.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... operational purposes such as hydraulic lift tanks and electrical equipment tanks. (4) Any UST system whose... are regulated under the Atomic Energy Act of 1954 (42 U.S.C. 2011 and following); (3) Any UST system...

  16. 40 CFR 280.10 - Applicability.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... operational purposes such as hydraulic lift tanks and electrical equipment tanks. (4) Any UST system whose... are regulated under the Atomic Energy Act of 1954 (42 U.S.C. 2011 and following); (3) Any UST system...

  17. Natural Attenuation of the Lead Scavengers 1,2-Dibromoethane (EDB) and 1.2-Dichloroethane (1,2-DCA) at Motor Fuel Release Sites and Implications for Risk Management

    EPA Science Inventory

    The lead scavengers 1,2-dibromoethane (EDB) and 1,2-dichloroethane (1,2-DCA) were included along with lead in conventional leaded gasoline used for automobiles in the US prior to 1988. Old spills of leaded gasoline from underground storage tank systems (USTs) at gasoline service...

  18. Investigation of Propellant Sloshing and Zero Gravity Equilibrium for the Orion Service Module Propellant Tanks

    NASA Astrophysics Data System (ADS)

    Kreppel, Samantha

    A scaled model of the downstream Orion service module propellant tank was constructed to asses the propellant dynamics under reduced and zero-gravity conditions. Flight and ground data from the experiment is currently being used to validate computational models of propel-lant dynamics in Orion-class propellant tanks. The high fidelity model includes the internal structures of the propellant management device (PMD) and the mass-gauging probe. Qualita-tive differences between experimental and CFD data are understood in terms of fluid dynamical scaling of inertial effects in the scaled system. Propellant configurations in zero-gravity were studied at a range of fill-fractions and the settling time for various docking maneuvers was determined. A clear understanding of the fluid dynamics within the tank is necessary to en-sure proper control of the spacecraft's flight and to maintain safe operation of this and future service modules. Understanding slosh dynamics in partially-filled propellant tanks is essential to assessing spacecraft stability.

  19. Closeup view of the External Tank and Solid Rocket Boosters ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Close-up view of the External Tank and Solid Rocket Boosters at the Launch Pad at Kennedy Space Center. Note the Hydrogen Vent Arm extending out from the Fixed Service Structure at attached to the Intertank segment of the External Tank. - Space Transportation System, Orbiter Discovery (OV-103), Lyndon B. Johnson Space Center, 2101 NASA Parkway, Houston, Harris County, TX

  20. General view looking out from the Fixed Service Structure at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    General view looking out from the Fixed Service Structure at Launch Complex 39 B at Kennedy Space Center. This view shows a Solid Rocket Booster (SRB) attached to the External Tank (ET) as well as the Orbiter Discovery attached to the ET for a complete launch stack assembly being prepared for launch. The most prominent features of the SRB shown in this view id the ET Attach Ring in the lower center of the view and the Systems Tunnel running vertically from the Aft Skirt Assembly, beyond the lower edge of this view, to the Forward Skirt near the Frustum at the top center of this view. - Space Transportation System, Solid Rocket Boosters, Lyndon B. Johnson Space Center, 2101 NASA Parkway, Houston, Harris County, TX

  1. 76 FR 45617 - Notice of Lodging of the Consent Decree Under the Resource Conservation and Recovery Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-29

    ... underground storage tank (UST) facilities; failure to perform annual tests of automatic line leak detectors... detectors for piping on the UST systems. CHEVRON also agrees under the Consent Decree to install dispenser...

  2. Composite Cryotank Technologies and Development 2.4 and 5.5M out of Autoclave Tank Test Results

    NASA Technical Reports Server (NTRS)

    Jackson, Justin R.; Vickers, John; Fikes, John

    2015-01-01

    The Composite Cryotank Technologies and Demonstration (CCTD) project substantially matured composite, cryogenic propellant tank technology. The project involved the design, analysis, fabrication, and testing of large-scale (2.4-m-diameter precursor and 5.5-m-diameter) composite cryotanks. Design features included a one-piece wall design that minimized tank weight, a Y-joint that incorporated an engineered material to alleviate stress concentration under combined loading, and a fluted core cylindrical section that inherently allows for venting and purging. The tanks used out-of-autoclave (OoA) cured graphite/epoxy material and processes to enable large (up to 10-m-diameter) cryotank fabrication, and thin-ply prepreg to minimize hydrogen permeation through tank walls. Both tanks were fabricated at Boeing using automated fiber placement on breakdown tooling. A fluted core skirt that efficiently carried axial loads and enabled hydrogen purging was included on the 5.5-m-diameter tank. Ultrasonic inspection was performed, and a structural health monitoring system was installed to identify any impact damage during ground processing. The precursor and 5.5-m-diameter tanks were tested in custom test fixtures at the National Aeronautics and Space Administration Marshall Space Flight Center. The testing, which consisted of a sequence of pressure and thermal cycles using liquid hydrogen, was successfully concluded and obtained valuable structural, thermal, and permeation performance data. This technology can be applied to a variety of aircraft and spacecraft applications that would benefit from 30 to 40% weight savings and substantial cost savings compared to aluminum lithium tanks.

  3. 78 FR 76143 - Proposed CERCLA Settlement Relating to the Paul's Tank Cleaning Service Superfund Site...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-16

    ... Paul's Tank Cleaning Service Superfund Site, Burlington County, New Jersey AGENCY: Environmental.... (``Settling Party''). The Settling Party is a potentially responsible party, pursuant to Section 107(a) of CERCLA, and thus is potentially liable for response costs incurred at or in connection Paul's Tank...

  4. 40 CFR 280.42 - Requirements for hazardous substance UST systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... UST systems. 280.42 Section 280.42 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... automatic line leak detector in accordance with § 280.44(a). (5) Other methods of release detection may be used if owners and operators: (i) Demonstrate to the implementing agency that an alternate method can...

  5. 49 CFR 179.201-3 - Lined tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Specifications for Non-Pressure Tank Car Tanks (Classes DOT-111AW and 115AW) § 179.201-3 Lined tanks. (a) Rubber... the service temperatures. (b) Before a tank car tank is lined with rubber, or other rubber compound, a... suitable for the service temperatures. (f) Polyvinyl chloride lined tanks. Tank car tanks or each...

  6. 12 CFR 618.8030 - Out-of-territory related services.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Related Services § 618.8030 Out-of-territory related services. (a) System banks and associations may offer... including timeframes. (b) System banks and associations providing out-of-territory services must fulfill all... 12 Banks and Banking 7 2012-01-01 2012-01-01 false Out-of-territory related services. 618.8030...

  7. 12 CFR 618.8030 - Out-of-territory related services.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Related Services § 618.8030 Out-of-territory related services. (a) System banks and associations may offer... including timeframes. (b) System banks and associations providing out-of-territory services must fulfill all... 12 Banks and Banking 6 2011-01-01 2011-01-01 false Out-of-territory related services. 618.8030...

  8. 12 CFR 618.8030 - Out-of-territory related services.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Related Services § 618.8030 Out-of-territory related services. (a) System banks and associations may offer... including timeframes. (b) System banks and associations providing out-of-territory services must fulfill all... 12 Banks and Banking 7 2013-01-01 2013-01-01 false Out-of-territory related services. 618.8030...

  9. One Approach to Contracting Out Services.

    ERIC Educational Resources Information Center

    Cryder, Ralph S.

    1985-01-01

    Public agencies can benefit from cost savings in forestry services, park security, and maintenance when park and recreation departments contract out for services. Pros and cons of contracting out and guidelines for this process are offered. (DF)

  10. Think Tanks

    NASA Technical Reports Server (NTRS)

    2001-01-01

    A new inspection robot from Solex Robotics Systems was designed to eliminate hazardous inspections of petroleum and chemical storage tanks. The submersible robot, named Maverick, is used to inspect the bottoms of tanks, keeping the tanks operational during inspection. Maverick is able to provide services that will make manual tank inspections obsolete. While the inspection is conducted, Maverick's remote human operators remain safe outside of the tank. The risk to human health and life is now virtually eliminated. The risk to the environment is also minimal because there is a reduced chance of spillage from emptying and cleaning the tanks, where previously, tons of pollutants were released through the process of draining and refilling.

  11. 40 CFR 280.210 - Participation in management.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 28 2012-07-01 2012-07-01 false Participation in management. 280.210... STORAGE TANKS (UST) Lender Liability § 280.210 Participation in management. The term “participating in the management of an UST or UST system” means that, subsequent to the effective date of this subpart, December 6...

  12. 40 CFR 280.210 - Participation in management.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 27 2014-07-01 2014-07-01 false Participation in management. 280.210... STORAGE TANKS (UST) Lender Liability § 280.210 Participation in management. The term “participating in the management of an UST or UST system” means that, subsequent to the effective date of this subpart, December 6...

  13. 40 CFR 280.210 - Participation in management.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 28 2013-07-01 2013-07-01 false Participation in management. 280.210... STORAGE TANKS (UST) Lender Liability § 280.210 Participation in management. The term “participating in the management of an UST or UST system” means that, subsequent to the effective date of this subpart, December 6...

  14. Use of Electrical Conductivity Logging to Characterize the Geological Context of Releases at UST Sites

    EPA Science Inventory

    Risk is the combination of hazard and exposure. Risk characterization at UST release sites has traditionally emphasized hazard (presence of residual fuel) with little attention to exposure. Exposure characterization often limited to a one-dimensional model such as the RBCA equa...

  15. Psychotherapeutic Treatment in Combination with Relaxation in a Flotation Tank: Effects on "Burn-Out Syndrome"

    ERIC Educational Resources Information Center

    Kjellgren, Anette; Buhrkall, Hanne; Norlander, Torsten

    2010-01-01

    The focus of this study was to investigate experiences gained from treatment combining relaxation in flotation tank with psychotherapy for sufferers from "burn-out syndrome". Six people participated in a ten week program. They were all interviewed; the data were analyzed using the Empirical Phenomenological Psychological method. Five…

  16. 40 CFR 280.91 - Compliance dates.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (UST) Financial Responsibility § 280.91 Compliance dates. Owners of petroleum underground storage tanks... marketing firms owning 1,000 or more USTs and all other UST owners that report a tangible net worth of $20... compliance with § 280.94(b) is required by: July 24, 1989. (b) All petroleum marketing firms owning 100-999...

  17. A storage gas tank is moved to a pallet in the O&C

    NASA Technical Reports Server (NTRS)

    2001-01-01

    KENNEDY SPACE CENTER, Fla. -- In the Operations and Checkout Building, workers check out the placement of one of four gas tanks on the Spacelab Logistics Double Pallet. Part of the STS- 104 payload, the storage tanks two gaseous oxygen and two gaseous nitrogen -- comprise the high pressure gas assembly that will be attached to the Joint Airlock Module during two spacewalks. The tanks will support future spacewalk operations from the Station and augment the Service Module gas resupply system.

  18. Site-specific standard request for underground storage tanks 1219-U, 1222-U, 2082-U, and 2068-U at the rust garage facility buildings 9754-1 and 9720-15: Oak Ridge Y-12 Plant, Oak Ridge, Tennessee, Facility ID No. 0-010117

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1994-12-01

    This document represents a Site-specific Standard Request for underground storage tanks (USTs) 1219-U,1222-U and 2082-U previously located at former Building 9754-1, and tank 2086-U previously located at Building 9720-15, Oak Ridge Y-12 Plant, Oak Ridge, Tennessee. The tanks previously contained petroleum products. For the purposes of this report, the two building sites will be regarded as a single UST site and will be referred to as the Rust Garage Facility. The current land use associated with the Y-12 Plant is light industrial and the operational period of the plant is projected to be at least 30 years. Thus, potential futuremore » residential exposures are not expected to occur for at least 30 years. Based on the degradation coefficient for benzene (the only carcinogenic petroleum constituent detected in soils or groundwater at the Rust Garage Facility), it is expected that the benzene and other contaminants at the site will likely be reduced prior to expiration of the 30-year plant operational period. As the original sources of petroleum contamination have been removed, and the area of petroleum contamination is limited, a site-specific standard is therefore being requested for the Rust Garage Facility.« less

  19. Construction concepts and validation of the 3D printed UST_2 modular stellarator

    NASA Astrophysics Data System (ADS)

    Queral, V.

    2015-03-01

    High accuracy, geometric complexity and thus high cost of stellarators tend to hinder the advance of stellarator research. Nowadays, new manufacturing methods might be developed for the production of small and middle-size stellarators. The methods should demonstrate advantages with respect common fabrication methods, like casting, cutting, forging and welding, for the construction of advanced highly convoluted modular stellarators. UST2 is a small modular three period quasi-isodynamic stellarator of major radius 0.26 m and plasma volume 10 litres being currently built to validate additive manufacturing (3D printing) for stellarator construction. The modular coils are wound in grooves defined on six 3D printed half period frames designed as light truss structures filled by a strong filler. A geometrically simple assembling configuration has been concocted for UST2 so as to try to lower the cost of the device while keeping the positioning accuracy of the different elements. The paper summarizes the construction and assembling concepts developed, the devised positioning methodology, the design of the coil frames and positioning elements and, an initial validation of the assembling of the components.

  20. Hanford tank initiative vehicle/based waste retrieval demonstration report phase II, track 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berglin, E.J.

    1997-07-31

    Using the versatile TracPUMpTm, Environmental Specialties Group, LLC (ES) performed a successful Phase 11 demonstration of a Vehicle- Based Waste Retrieval System (VWRS) for removal of waste material and residual liquid found in the Hanford Underground Storage Tanks (ousts). The purpose of this demonstration was to address issues pertaining to the use of a VWRS in OUSTS. The demonstration also revealed the waste removal capabilities of the TracPumpTm and the most effective techniques and equipment to safely and effectively remove waste simulants. ES successfully addressed the following primary issues: I . Dislodge and convey the waste forms present in themore » Hanford OUSTS; 2. Access the UST through tank openings as small as twenty-four inches in diameter; 3. Traverse a variety of terrains including slopes, sludges, rocks and hard, slippery surfaces without becoming mired; 4. Dislodge and convey waste within the confinement of the Decontamination Containment Capture Vessel (DCCV) and with minimal personnel exposure; 5. Decontaminate equipment to acceptable limits during retrieval from the UST; 6. Perform any required maintenance within the confinement of the DCCV; and 7. Maintain contaminate levels ``as low as reasonably achievable`` (ALARA) within the DCCV due to its crevice and comer-free design. The following materials were used to simulate the physical characteristics of wastes found in Hanford`s OUSTS: (1) Hardpan: a clay-type material that has high shear strength; (2) Saltcake: a fertilizer-based material that has high compressive strength; and (3) Wet Sludge.- a sticky, peanut- butter- like material with low shear strength. Four test beds were constructed of plywood and filled with a different simulant to a depth of eight to ten inches. Three of the test beds were of homogenous simulant material, while the fourth bed consisted of a mixture of all three simulant types.« less

  1. 40 CFR 280.31 - Operation and maintenance of corrosion protection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 27 2014-07-01 2014-07-01 false Operation and maintenance of corrosion... UNDERGROUND STORAGE TANKS (UST) General Operating Requirements § 280.31 Operation and maintenance of corrosion protection. All owners and operators of steel UST systems with corrosion protection must comply with the...

  2. 40 CFR 280.31 - Operation and maintenance of corrosion protection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 28 2012-07-01 2012-07-01 false Operation and maintenance of corrosion... UNDERGROUND STORAGE TANKS (UST) General Operating Requirements § 280.31 Operation and maintenance of corrosion protection. All owners and operators of steel UST systems with corrosion protection must comply with the...

  3. 40 CFR 280.31 - Operation and maintenance of corrosion protection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 28 2013-07-01 2013-07-01 false Operation and maintenance of corrosion... UNDERGROUND STORAGE TANKS (UST) General Operating Requirements § 280.31 Operation and maintenance of corrosion protection. All owners and operators of steel UST systems with corrosion protection must comply with the...

  4. Corrective Action Investigation Plan for Corrective Action Unit 127: Areas 25 and 26 Storage Tanks, Nevada Test Site, Nevada (Rev. No.: 0, August 2002)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NNSA /NV

    This Corrective Action Investigation Plan (CAIP) contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Offices's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 127 under the Federal Facility Agreement and Consent Order. Corrective Action Unit 127 is located on the Nevada Test Site approximately 65 miles northwest of Las Vegas, Nevada. This CAU is comprised of 12 Corrective Action Sites (CASs) located at Test Cell C; the Engine Maintenance, Assembly, and Disassembly (E-MAD) Facility; the X-Tunnel in Area 25; the Pluto Disassembly Facility; themore » Pluto Check Station; and the Port Gaston Training Facility in Area 26. These CASs include: CAS 25-01-05, Aboveground Storage Tank (AST); CAS 25-02-02, Underground Storage Tank (UST); CAS 25-23-11, Contaminated Materials; CAS 25-12-01, Boiler; CAS 25-01-06, AST; CAS 25-01-07, AST; CAS 25-02-13, UST; CAS 26- 01-01, Filter Tank (Rad) and Piping; CAS 26-01-02, Filter Tank (Rad); CAS 26-99-01, Radioactively Contaminated Filters; CAS 26-02-01, UST; CAS 26-23-01, Contaminated Liquids Spreader. Based on site history, process knowledge, and previous field efforts, contaminants of potential concern for CAU 127 include radionuclides, metals, total petroleum hydrocarbons, volatile organic compounds, asbestos, and polychlorinated biphenyls. Additionally, beryllium may be present at some locations. The sources of potential releases are varied, but releases of contaminated liquids may have occurred and may have migrated into and impacted soil below and surrounding storage vessels at some of the CASs. Also, at several CASs, asbestos-containing materials may be present on the aboveground structures and may be friable. Exposure pathways are limited to ingestion, inhalation, and dermal contact (adsorption) of soils/sediments or liquids, or inhalation of contaminants by site workers due to disturbance

  5. Postconstruction report for the mercury tanks interim action at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Voskuil, T.L.

    1993-09-01

    Three underground concrete settling tanks (tanks 2101-U, 2104-U, and 2100-U) at the Y-12 Plant on the Oak Ridge Reservation in Oak Ridge, Tennessee, contained contaminated sludges contributing mercury to the Upper East Fork Poplar Creek (UEFPC). These tanks were cleaned out as an interim action under the Comprehensive Environmental Response, Compensation, and Liability Act as part of the Reduction of Mercury in Plant Effluent subproject. Cleaning out these tanks prevented the sludge that had settled in the bottom from resuspending and carrying mercury into UEFPC. Tanks 2104-U and 2100-U were returned to service and will continue to receive effluent frommore » buildings 9201-4 and 9201-5. Tank 2101-U had been abandoned and its effluent redirected to Tank 2100-U during previous activities. This interim action permanently sealed Tank 2101-U from the storm sewer system. Upon removal of materials and completion of cleanup, inspections determined that the project`s cleanup criteria had been met. The structural integrity of the tanks was also inspected, and minor cracks identified in tanks 2101-U and 2104-U were repaired. This project is considered to have been completed successfully because it met its performance objectives as addressed in the Interim Record of Decision and the work plan: to remove the waste from the three storage tanks; to ensure that the tanks were cleaned to the levels specified; to return tanks 2100-U and 2104-U to service; to isolate Tank 2101-U permanently; and to manage the wastes in an appropriate fashion.« less

  6. 12 CFR 618.8030 - Out-of-territory related services.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Out-of-territory related services. 618.8030 Section 618.8030 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM GENERAL PROVISIONS Related Services § 618.8030 Out-of-territory related services. (a) System banks and associations may offer...

  7. Gluability of out-of-service utility poles

    Treesearch

    Han Roliadi; Chung Y. Hse; Elvin T. Choong; Todd F. Shupe

    2000-01-01

    This investigation determined the gluability of weathered, out-of-service southern yellow pine (SYP) (Pinus spp.) utility poles. Three types of adhesives were used: resorcinol-phenol formaldehyde (RPF), polyvinyl acetate (PVA), and casein. The poles consisted of two service duration groups: 5 and 25 years. Longer weathering caused greater reduction in creosote content...

  8. PERFORMANCE OF CONVENTIONAL REMEDIAL TECHNOLOGY FOR TREATMENT OF MTBE AND BENZENE AT UST SITES IN KANSAS

    EPA Science Inventory

    Ground water at most UST spills sites in Kansas contains both MTBE and benzene, and both contaminants must be effectively treated to close the sites. Soil vacuum extraction, air sparging, and excavation are the most common treatment technologies in Kansas. To compare the relati...

  9. 76 FR 71707 - Revising Underground Storage Tank Regulations-Revisions to Existing Requirements and New...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-18

    ... Equipment C. Addressing Deferrals 1. Emergency Power Generator UST Systems 2. Airport Hydrant Fuel.... Maintain Deferral for USTs Containing Radioactive Material and Emergency Generator UST Systems at Nuclear... (air, water, 481, 483-486, 48811. truck, transit, pipeline, and airport operations). Communications and...

  10. 40 CFR 280.22 - Notification requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 280.22 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES... STORAGE TANKS (UST) UST Systems: Design, Construction, Installation and Notification § 280.22 Notification... to notify the designated state or local agency in accordance with the Hazardous and Solid Waste...

  11. 40 CFR 280.22 - Notification requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Section 280.22 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES... STORAGE TANKS (UST) UST Systems: Design, Construction, Installation and Notification § 280.22 Notification... to notify the designated state or local agency in accordance with the Hazardous and Solid Waste...

  12. 40 CFR 280.22 - Notification requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Section 280.22 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES... STORAGE TANKS (UST) UST Systems: Design, Construction, Installation and Notification § 280.22 Notification... to notify the designated state or local agency in accordance with the Hazardous and Solid Waste...

  13. 40 CFR 280.22 - Notification requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Section 280.22 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES... STORAGE TANKS (UST) UST Systems: Design, Construction, Installation and Notification § 280.22 Notification... to notify the designated state or local agency in accordance with the Hazardous and Solid Waste...

  14. 40 CFR 280.22 - Notification requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Section 280.22 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES... STORAGE TANKS (UST) UST Systems: Design, Construction, Installation and Notification § 280.22 Notification... to notify the designated state or local agency in accordance with the Hazardous and Solid Waste...

  15. ETV REPORT & STATEMENT: EVALUATION OF THE KCH SERVICES, INC. AUTOMATED COVERED TANK SYSTEM FOR ENERGY CONSERVATION

    EPA Science Inventory

    KCH Services, Inc. manufacturers a commercial-ready energy conserving automatic covered tank system for use in the metal finishing industry. The ACTSEC technology is a system designed to provide an efficient removal of air contaminants from the workplace at a reasonable cost and ...

  16. Final Environmental Assessment Addressing a Proposed Commissary at Dobbins Air Reserve Base, Georgia

    DTIC Science & Technology

    2012-11-01

    Response HMMS Hazardous Materials Management System HQ Headquarters HUD U.S. Department of Housing and Urban Development HVAC heating, ventilation ...Environmental Protection Agency USFWS U.S. Fish and Wildlife Service USGS U.S Geological Survey UST underground storage tank VOC volatile organic...li\\fPACT I conclude that the environmental effects of the proposed commissary at Dobbins ARB are not significant, that preparation of an

  17. Comparison of Smoking and Khat Chewing Habits between Medical and Non-Medical Female Students at UST, Sana'a, Yemen.

    PubMed

    Kubas, Mohammed Abdullah; Wadi, Majed

    2015-01-01

    Smoking is a worldwide problem that kills millions of people. Women smoke much lower than males but the numbers of smoker women are growing up. The objectives of this study were to assess the prevalence of smoking and khat chewing in medical and non-medical female students at University of Science and Technology (UST), Sana'a, Yemen. We used self-administrated questionnaire to collect cross-sectional data from a randomly selected sample of medical and non-medical female students of UST in 2012-2013. Overall, 480 students completed and returned the questionnaire, of them medical students represented 50% of them. The prevalence of smoking was significantly low among female medical students (P=0.045), however, not significantly difference was found between medical and non-medical female students in khat chewing habits (P=0.083). Non-smoker medical female students who tried smoking (45.6%) were significantly lower than non-medical students (54.4%), and curiosity was the main reason for trying smoking. Water pipe was the most common type of smoking among smoker students (78.6%). Out of 26 female students who smoke and chew khat, 18 students reported that they smoke more while they chew khat. Our study highlights the need for increased health education, awareness, and knowledge of the risks of smoking and particularly khat chewing to reduce these habits among female university students especially in non-medical female students.

  18. Relocating from out-of-area treatments: service users' perspective.

    PubMed

    Rambarran, D D

    2013-10-01

    Asylum closures over recent decades resulted in mental health services being increasingly sited in the community. However, under provision of highly supported accommodation led to service users being placed away from their local area in 'out-of-area treatments' (OATs). OATs have raised major concerns in relation to enabling service users' recovery, owing to limitations in promoting autonomy, social dislocation and costs. In 2004, an OATs project was set up in a London Borough to address these concerns. In the first 4 years, the project succeeded in relocating 22 service users to less restrictive environments locally. This study aims to explore the outcome of relocation from service users' perspective. A qualitative methodology was utilized. Semi-structured interviews were carried out with seven service users who relocated. All seven service users shared a strong aspiration for independent living but there was associated loneliness. Five welcomed increased contact with family and friends, but lacked social confidence, inhibiting social inclusion. Service users with long-term and consistent care managers were more able to address fears. Five out of seven service users concluded that relocation increased their autonomy thus enhanced their quality of life. © 2012 John Wiley & Sons Ltd.

  19. Evaluation of waste tank 16 using a field mercury analyzer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Looney, B.; Cook, J.R.

    1988-05-12

    Liquid radioactive wastes from the chemical processing of nuclear materials at the Savannah River Plant (SRP) are stored in large tanks buried near the ground surface. Each tank has multiple containment barriers designed to prevent leakage to the surrounding soil and groundwater. The only incident in which waste leaked through the multiple containment of a waste tank at SRP occurred at Tank 16 on September 8, 1960 (Poe, 1974; Prendergast, 1982). Tank 16 was built in 1955 and has a capacity of approximately one million gallons. Tank 16 consists of a steel primary containment vessel resting in a shallow steelmore » pan. A massive concrete encasement surrounds the tank and pan. After the leak in 1960, the tank was removed from service until 1967; at that time it was placed into service for lower activity wastes. In 1972 the tank was removed from service. Subsequently, all of the waste except a sludge heel of 67,000 gallons was removed from the tank. In 1980, this sludge was removed. Following the sludge removal, the tank was exhaustively cleaned and rinsed. Concentrations of radioactivity in the rinsewater suggested that the cleaning of the tank was effective (West and Morris, 1980). Recently, there has been concern about residual nonradioactive constituents, such as mercury, in the tank. To assist in evaluating the potential for residual mercury contamination, a survey method was developed and a survey of several tanks was conducted. 3 refs., 1 tab.« less

  20. Validation of computational code UST3D by the example of experimental aerodynamic data

    NASA Astrophysics Data System (ADS)

    Surzhikov, S. T.

    2017-02-01

    Numerical simulation of the aerodynamic characteristics of the hypersonic vehicles X-33 and X-34 as well as spherically blunted cone is performed using the unstructured meshes. It is demonstrated that the numerical predictions obtained with the computational code UST3D are in acceptable agreement with the experimental data for approximate parameters of the geometry of the hypersonic vehicles and in excellent agreement with data for blunted cone.

  1. Massachusetts Institute of Technology Lincoln Laboratory Facilities Replacement on Hanscom Air Force Base Phase 1 Final Environmental Assessment

    DTIC Science & Technology

    2014-07-24

    Service UST Underground Storage Tank VC Vitrified Clay VOCs Volatile Organic Compounds W Watts 1 1.0 PURPOSE AND NEED FOR ACTION 1.1 INTRODUCTION The...discharged to sanitary drain and the solids slurry is hauled off site for disposal Fluoride drain: welded stainless steel drain piping from wet...diameter vitrified clay (VC) gravity sewer collection pipe, flowing north/northeast to the upper pumping station at Building 1306, is located within the

  2. DECISION-SUPPORT SOFTWARE FOR SOIL VAPOR EXTRACTION TECHNOLOGY APPLICATION: HYPERVENTILATE

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA) estimate* that 15% to 20% of the approximately 1.7 million underground storage tank (UST) systems containing petroleum products are either leaking or will leak In the near future. These UST systems could pose a serious threat to p...

  3. 49 CFR 395.13 - Drivers declared out of service.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... materials requirements prescribed in § 397.5 pertaining to attendance and surveillance of commercial motor... shall: (i) Require or permit a driver who has been declared out of service to operate a commercial motor... been declared out of service for failure to prepare a record of duty status to operate a commercial...

  4. 49 CFR 195.432 - Inspection of in-service breakout tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... low-pressure steel aboveground breakout tanks according to API Standard 653 (incorporated by reference... breakout tanks built to API Standard 2510 according to section 6 of API 510. (d) The intervals of...

  5. 49 CFR 195.432 - Inspection of in-service breakout tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... low-pressure steel aboveground breakout tanks according to API Standard 653 (incorporated by reference... breakout tanks built to API Standard 2510 according to section 6 of API 510. (d) The intervals of...

  6. 49 CFR 195.432 - Inspection of in-service breakout tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... low-pressure steel aboveground breakout tanks according to API Standard 653 (incorporated by reference... breakout tanks built to API Standard 2510 according to section 6 of API 510. (d) The intervals of...

  7. 49 CFR 195.432 - Inspection of in-service breakout tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... low-pressure steel aboveground breakout tanks according to API Standard 653 (incorporated by reference... breakout tanks built to API Standard 2510 according to section 6 of API 510. (d) The intervals of...

  8. 49 CFR 195.432 - Inspection of in-service breakout tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... low-pressure steel aboveground breakout tanks according to API Standard 653 (incorporated by reference... breakout tanks built to API Standard 2510 according to section 6 of API 510. (d) The intervals of...

  9. The Finite Element Modelling and Dynamic Characteristics Analysis about One Kind of Armoured Vehicles’ Fuel Tanks

    NASA Astrophysics Data System (ADS)

    Gao, Yang; Ge, Zhishang; Zhai, Weihao; Tan, Shiwang; Zhang, Feng

    2018-01-01

    The static and dynamic characteristics of fuel tank are studied for the armoured vehicle in this paper. The CATIA software is applied to build the CAD model of the armoured vehicles’ fuel tank, and the finite element model is established in ANSYS Workbench. The finite element method is carried out to analyze the static and dynamic mechanical properties of the fuel tank, and the first six orders of mode shapes and their frequencies are also computed and given in the paper, then the stress distribution diagram and the high stress areas are obtained. The results of the research provide some references to the fuel tanks’ design improvement, and give some guidance for the installation of the fuel tanks on armoured vehicles, and help to improve the properties and the service life of this kind of armoured vehicles’ fuel tanks.

  10. 7 CFR 58.427 - Paraffin tanks.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Paraffin tanks. 58.427 Section 58.427 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....427 Paraffin tanks. The metal tank should be adequate in size, have wood rather than metal racks to...

  11. 7 CFR 58.427 - Paraffin tanks.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Paraffin tanks. 58.427 Section 58.427 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....427 Paraffin tanks. The metal tank should be adequate in size, have wood rather than metal racks to...

  12. 7 CFR 58.427 - Paraffin tanks.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Paraffin tanks. 58.427 Section 58.427 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....427 Paraffin tanks. The metal tank should be adequate in size, have wood rather than metal racks to...

  13. 7 CFR 58.427 - Paraffin tanks.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Paraffin tanks. 58.427 Section 58.427 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....427 Paraffin tanks. The metal tank should be adequate in size, have wood rather than metal racks to...

  14. 7 CFR 58.427 - Paraffin tanks.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Paraffin tanks. 58.427 Section 58.427 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....427 Paraffin tanks. The metal tank should be adequate in size, have wood rather than metal racks to...

  15. Taxonomic composition and biostratigraphic value of the Early Riphean organic-walled microfossil association from the Ust'-Il'ya Formation of the Anabar Uplift, Northern Siberia

    NASA Astrophysics Data System (ADS)

    Sergeev, V. N.; Vorob'eva, N. G.; Petrov, P. Yu.; Semikhatov, M. A.

    2017-05-01

    It is demonstrated on the basis of the first monographic study of multiple and taxonomically variable organic-walled microfossils from the Ust'-Il'ya Formation of the Anabar Uplift that both prokaryotic and eukaryotic forms are present in the composition of this microbiota. They are divided into four formal groups on the basis of the specifics of the morphological indicators of the identified taxa. The review of the data on the isotopic age of hosting deposits showed that the Ust'-Il'ya Formation is of the Early Riphean in age which are currently evaluated as 1750 ± 10-1400 Ma. Relatively large and morphologically complex eukaryotic forms present in the Ust'-Il'ya Formation served in due time as the basis for an erroneous conclusion on the Late Riphean age of the specified formation and the overlying Lower Kotuikan Subformation of the Anabar Uplift. The paper provides a global comparative analysis of the Early Riphean microbiotas, demonstrates the position of the Ust'-Il'ya and Kotuikan microbiotas amidst the microbiotas of the same age, and shows that the relatively large acanthomorphic acritarchs Tappania, Valeria, Dictiosphaera, Satka, and Shuiyousphaeridium appeared in the geological history already during the Early Riphean Erathem. Moreover, the paper discusses the recently published data on the distribution of aerobic and anaerobic conditions in the Early Riphean paleobasins and provides the conclusion on the impact of the lateral change of these conditions on the taxonomic composition of the microbiota.

  16. 49 CFR 195.205 - Repair, alteration and reconstruction of aboveground breakout tanks that have been in service.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., examination, and material requirements of those respective standards. (3) For high pressure tanks built to API... service must be capable of withstanding the internal pressure produced by the hazardous liquid to be... approximately atmospheric pressure constructed of carbon and low alloy steel, welded or riveted, and non...

  17. 40 CFR 280.12 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Amendments and Reauthorization Act of 1986. Septic tank is a water-tight covered receptacle designed to... premises where stored; (c) Septic tank; (d) Pipeline facility (including gathering lines) regulated under... STANDARDS AND CORRECTIVE ACTION REQUIREMENTS FOR OWNERS AND OPERATORS OF UNDERGROUND STORAGE TANKS (UST...

  18. Compact photoacoustic tomography system

    NASA Astrophysics Data System (ADS)

    Kalva, Sandeep Kumar; Pramanik, Manojit

    2017-03-01

    Photoacoustic tomography (PAT) is a non-ionizing biomedical imaging modality which finds applications in brain imaging, tumor angiogenesis, monitoring of vascularization, breast cancer imaging, monitoring of oxygen saturation levels etc. Typical PAT systems uses Q-switched Nd:YAG laser light illumination, single element large ultrasound transducer (UST) as detector. By holding the UST in horizontal plane and moving it in a circular motion around the sample in full 2π radians photoacoustic data is collected and images are reconstructed. The horizontal positioning of the UST make the scanning radius large, leading to larger water tank and also increases the load on the motor that rotates the UST. To overcome this limitation, we present a compact photoacoustic tomographic (ComPAT) system. In this ComPAT system, instead of holding the UST in horizontal plane, it is held in vertical plane and the photoacoustic waves generated at the sample are detected by the UST after it is reflected at 45° by an acoustic reflector attached to the transducer body. With this we can reduce the water tank size and load on the motor, thus overall PAT system size can be reduced. Here we show that with the ComPAT system nearly similar PA images (phantom and in vivo data) can be obtained as that of the existing PAT systems using both flat and cylindrically focused transducers.

  19. 49 CFR 230.115 - Feed water tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Feed water tanks. 230.115 Section 230.115... Tenders Steam Locomotive Tanks § 230.115 Feed water tanks. (a) General provisions. Tanks shall be maintained free from leaks, and in safe and suitable condition for service. Suitable screens must be provided...

  20. Double-Shell Tank Visual Inspection Changes Resulting from the Tank 241-AY-102 Primary Tank Leak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Girardot, Crystal L.; Washenfelder, Dennis J.; Johnson, Jeremy M.

    2013-11-14

    As part of the Double-Shell Tank (DST) Integrity Program, remote visual inspections are utilized to perform qualitative in-service inspections of the DSTs in order to provide a general overview of the condition of the tanks. During routine visual inspections of tank 241-AY-102 (AY-102) in August 2012, anomalies were identified on the annulus floor which resulted in further evaluations. In October 2012, Washington River Protection Solutions, LLC determined that the primary tank of AY-102 was leaking. Following identification of the tank AY-102 probable leak cause, evaluations considered the adequacy of the existing annulus inspection frequency with respect to the circumstances ofmore » the tank AY-102 1eak and the advancing age of the DST structures. The evaluations concluded that the interval between annulus inspections should be shortened for all DSTs, and each annulus inspection should cover > 95 percent of annulus floor area, and the portion of the primary tank (i.e., dome, sidewall, lower knuckle, and insulating refractory) that is visible from the annulus inspection risers. In March 2013, enhanced visual inspections were performed for the six oldest tanks: 241-AY-101, 241-AZ-101,241-AZ-102, 241-SY-101, 241-SY-102, and 241-SY-103, and no evidence of leakage from the primary tank were observed. Prior to October 2012, the approach for conducting visual examinations of DSTs was to perform a video examination of each tank's interior and annulus regions approximately every five years (not to exceed seven years between inspections). Also, the annulus inspection only covered about 42 percent of the annulus floor.« less

  1. 46 CFR 56.50-85 - Tank-vent piping.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... this requirement. (4) Tank vents must extend above the weather deck, except vents from fresh water tanks, bilge oily-water holding tanks, bilge slop tanks, and tanks containing Grade E combustible... barges in inland service and for Great Lakes vessels, the height from the deck to any point where water...

  2. 46 CFR 56.50-85 - Tank-vent piping.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... this requirement. (4) Tank vents must extend above the weather deck, except vents from fresh water tanks, bilge oily-water holding tanks, bilge slop tanks, and tanks containing Grade E combustible... barges in inland service and for Great Lakes vessels, the height from the deck to any point where water...

  3. 46 CFR 56.50-85 - Tank-vent piping.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... this requirement. (4) Tank vents must extend above the weather deck, except vents from fresh water tanks, bilge oily-water holding tanks, bilge slop tanks, and tanks containing Grade E combustible... barges in inland service and for Great Lakes vessels, the height from the deck to any point where water...

  4. Tank Inspection NDE Results for Fiscal Year 2014, Waste Tanks 26, 27, 28 and 33

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elder, J.; Vandekamp, R.

    2014-09-29

    Ultrasonic nondestructive examinations (NDE) were performed on waste storage tanks 26, 27, 28 and 33 at the Savannah River Site as a part of the “In-Service Inspection (ISI) Program for High Level Waste Tanks.” No reportable conditions were identified during these inspections. The results indicate that the implemented corrosion control program continues to effectively mitigate corrosion in the SRS waste tanks. Ultrasonic inspection (UT) is used to detect general wall thinning, pitting and interface attack, as well as vertically oriented cracks through inspection of an 8.5 inch wide strip extending over the accessible height of the primary tank wall andmore » accessible knuckle regions. Welds were also inspected in tanks 27, 28 and 33 with no reportable indications. In a Type III/IIIA primary tank, a complete vertical strip includes scans of five plates (including knuckles) so five “plate/strips” would be completed at each vertical strip location. In FY 2014, a combined total of 79 plate/strips were examined for thickness mapping and crack detection, equating to over 45,000 square inches of area inspected on the primary tank wall. Of the 79 plate/strips examined in FY 2014 all but three have average thicknesses that remain at or above the construction minimum thickness which is nominal thickness minus 0.010 inches. There were no service induced reportable thicknesses or cracking encountered. A total of 2 pits were documented in 2014 with the deepest being 0.032 inches deep. One pit was detected in Tank 27 and one in Tank 33. No pitting was identified in Tanks 26 or 28. The maximum depth of any pit encountered in FY 2014 is 5% of nominal thickness, which is less than the minimum reportable criteria of 25% through-wall for pitting. In Tank 26 two vertical strips were inspected, as required by the ISI Program, due to tank conditions being outside normal chemistry controls for more than 3 months. Tank 28 had an area of localized thinning on the exterior wall

  5. Report to Congress on a Compliance Plan for the Underground Storage Tank Program

    EPA Pesticide Factsheets

    Learn about identification of USTs that are not in compliance with Subtitle I of the Solid Waste Disposal Act or are in temporary closure, and determine the ownership of USTs not in compliance or in temporary closure

  6. Service for Out-of-Wedlock Children in Korea.

    ERIC Educational Resources Information Center

    Huh, Nam Soon

    1993-01-01

    Describes care services for out-of-wedlock children in Korea, which include out-of-country and in-country adoption, foster home care, child-care institutions, child support allowances, residential facilities for single mothers and their children, day care, housing support, and maternity group homes. Discusses systems for delivering and financing…

  7. Thermography to Inspect Insulation of Large Cryogenic Tanks

    NASA Technical Reports Server (NTRS)

    Arens, Ellen; Youngquist, Robert

    2011-01-01

    Thermography has been used in the past to monitor active, large, cryogenic storage tanks. This approach proposes to use thermography to monitor new or refurbished tanks, prior to filling with cryogenic liquid, to look for insulation voids. Thermography may provide significant cost and schedule savings if voids can be detected early before a tank is returned to service.

  8. ANNUAL RADIOACTIVE WASTE TANK INSPECTION PROGRAM- 2007

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    West, B; Ruel Waltz, R

    2008-06-05

    Aqueous radioactive wastes from Savannah River Site (SRS) separations and vitrification processes are contained in large underground carbon steel tanks. The 2007 inspection program revealed that the structural integrity and waste confinement capability of the Savannah River Site waste tanks were maintained. A very small amount of material had seeped from Tank 12 from a previously identified leaksite. The material observed had dried on the tank wall and did not reach the annulus floor. A total of 5945 photographs were made and 1221 visual and video inspections were performed during 2007. Additionally, ultrasonic testing was performed on four Waste Tanksmore » (15, 36, 37 and 38) in accordance with approved inspection plans that met the requirements of WSRC-TR-2002- 00061, Revision 2 'In-Service Inspection Program for High Level Waste Tanks'. The Ultrasonic Testing (UT) In-Service Inspections (ISI) are documented in a separate report that is prepared by the ISI programmatic Level III UT Analyst. Tanks 15, 36, 37 and 38 are documented in 'Tank Inspection NDE Results for Fiscal Year 2007'; WSRC-TR-2007-00064.« less

  9. 7 CFR 58.321 - Cream storage tanks.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Cream storage tanks. 58.321 Section 58.321 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....321 Cream storage tanks. Cream storage tanks shall meet the requirements of § 58.128(d). Cream storage...

  10. 7 CFR 58.321 - Cream storage tanks.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Cream storage tanks. 58.321 Section 58.321 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....321 Cream storage tanks. Cream storage tanks shall meet the requirements of § 58.128(d). Cream storage...

  11. 7 CFR 58.321 - Cream storage tanks.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Cream storage tanks. 58.321 Section 58.321 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....321 Cream storage tanks. Cream storage tanks shall meet the requirements of § 58.128(d). Cream storage...

  12. In-tank recirculating arsenic treatment system

    DOEpatents

    Brady, Patrick V [Albuquerque, NM; Dwyer, Brian P [Albuquerque, NM; Krumhansl, James L [Albuquerque, NM; Chwirka, Joseph D [Tijeras, NM

    2009-04-07

    A low-cost, water treatment system and method for reducing arsenic contamination in small community water storage tanks. Arsenic is removed by using a submersible pump, sitting at the bottom of the tank, which continuously recirculates (at a low flow rate) arsenic-contaminated water through an attached and enclosed filter bed containing arsenic-sorbing media. The pump and treatment column can be either placed inside the tank (In-Tank) by manually-lowering through an access hole, or attached to the outside of the tank (Out-of-Tank), for easy replacement of the sorption media.

  13. Romanenko looks through a Rodnik Tank in the SM

    NASA Image and Video Library

    2012-12-31

    ISS034-E-010446 (31 Dec. 2012) --- Russian cosmonaut Roman Romanenko, Expedition 34 flight engineer, looks through a Rodnik tank in the Zvezda Service Module of the International Space Station. Romanenko performed a water transfer from a Rodnik tank in the Progress to a Rodnik tank in the Zvezda Service Module. Note the multiple refractions of the cosmonaut?s head and shoulders in the bubbles.

  14. 40 CFR 282.96 - Virginia State-Administered Program.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...” includes heating oil tanks of greater than 5,000 gallon capacity and “Regulated substance” 9 VAC 25-580-130General requirements for all petroleum and hazardous substance UST systems, heating oil tanks of greater... WASTES (CONTINUED) APPROVED UNDERGROUND STORAGE TANK PROGRAMS Approved State Programs § 282.96 Virginia...

  15. CEMENTITIOUS GROUT FOR CLOSING SRS HIGH LEVEL WASTE TANKS - #12315

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Langton, C.; Burns, H.; Stefanko, D.

    2012-01-10

    In 1997, the first two United States Department of Energy (US DOE) high level waste tanks (Tanks 17-F and 20-F: Type IV, single shell tanks) were taken out of service (permanently closed) at the Savannah River Site (SRS). In 2012, the DOE plans to remove from service two additional Savannah River Site (SRS) Type IV high-level waste tanks, Tanks 18-F and 19-F. These tanks were constructed in the late 1950's and received low-heat waste and do not contain cooling coils. Operational closure of Tanks 18-F and 19-F is intended to be consistent with the applicable requirements of the Resource Conservationmore » and Recovery Act (RCRA) and the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) and will be performed in accordance with South Carolina Department of Health and Environmental Control (SCDHEC). The closure will physically stabilize two 4.92E+04 cubic meter (1.3 E+06 gallon) carbon steel tanks and isolate and stabilize any residual contaminants left in the tanks. The closure will also fill, physically stabilize and isolate ancillary equipment abandoned in the tanks. A Performance Assessment (PA) has been developed to assess the long-term fate and transport of residual contamination in the environment resulting from the operational closure of the F-Area Tank Farm (FTF) waste tanks. Next generation flowable, zero-bleed cementitious grouts were designed, tested, and specified for closing Tanks 18-F and 19-F and for filling the abandoned equipment. Fill requirements were developed for both the tank and equipment grouts. All grout formulations were required to be alkaline with a pH of 12.4 and chemically reduction potential (Eh) of -200 to -400 to stabilize selected potential contaminants of concern. This was achieved by including Portland cement and Grade 100 slag in the mixes, respectively. Ingredients and proportions of cementitious reagents were selected and adjusted, respectively, to support the mass placement strategy developed by

  16. A tiered approach to distinguish sources of gasoline and diesel spills.

    PubMed

    Xiong, Wenhui; Bernesky, Ryan; Bechard, Robert; Michaud, Guy; Lang, Jeremy

    2014-07-15

    Approximately 11% and 25% of annual Canadian oil spill accidents are gasoline and diesel spills, respectively. Gasoline and diesel spills are a challenge to conventional environmental forensic techniques because refinery processes remove most of the higher molecular weight biomarkers. This study presents a tiered environmental forensics strategy that includes such information as site operational history, geology/hydrogeology, GC/FID pre-screening, volatile GC/MS, semi-volatile GC/MS, and GC/MS selected ion monitoring (SIM) chromatograms for fingerprinting of gasoline and diesel spills. GC/FID pre-screening analysis identified the presence of two individual gasoline and diesel plumes at a fuel service station (study site). The gasoline plume is present between the upgradient fuel underground storage tanks (USTs) and the downgradient diesel plume, suggesting that the diesel impacts to groundwater may not be originated from the current UST leakage. Similar distribution of C3-alkylbenzenes (the most stable chemicals in gasoline) and the consistent diagnostic ratios of the analyte pairs with similar solubility indicate that the source for the dissolved gasoline constituents in the gasoline impacted zone likely originated from a gasoline leakage from the current USTs on the study site. In the diesel impacted zone, the distinct distribution and diagnostic ratios of sesquiterpanes (biomarkers for diesel) and alkylated PAHs confirm that the diesel plume originate from different crude oil sources than the current USTs. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. The University of St. Thomas' Service-Learning Program: Matching the University's Catholic Mission to Greater Community Needs

    ERIC Educational Resources Information Center

    Garcia-Contreras, Rogelio; Faletta, Jean-Philippe; Krustchinsky, Rick

    2011-01-01

    The University of St. Thomas (UST) is a private Catholic liberal arts university in Houston, Texas, whose mission includes a commitment to service. The pedagogy of service-learning aligns well with the school's mission and with the teachings and social doctrine of the Catholic Church. Designed to expand opportunities for the procurement of the…

  18. TECHNICAL ASPECTS OF UNDERGROUND STORAGE TANK CLOSURE

    EPA Science Inventory

    The overall objective of the study was to develop a deeper understanding of UST residuals at closure: their quantities, origins, physical/chemical properties, ease of removal by various cleaning methods, and their environmental mobility and persistence. The investigation covered ...

  19. View of Stand Pipe (Surge Tank) from FS 502. Looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View of Stand Pipe (Surge Tank) from FS 502. Looking northeast - Childs-Irving Hydroelectric Project, Childs System, Stand Pipe (Surge Tank), Forest Service Road 708/502, Camp Verde, Yavapai County, AZ

  20. 46 CFR 76.25-20 - Pressure tank.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false Pressure tank. 76.25-20 Section 76.25-20 Shipping COAST... Sprinkling System, Details § 76.25-20 Pressure tank. (a) A pressure tank or other suitable means shall be... shall be carried in the tank to fill the piping of the largest zone, and in addition, force out at least...

  1. 46 CFR 76.25-20 - Pressure tank.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 3 2012-10-01 2012-10-01 false Pressure tank. 76.25-20 Section 76.25-20 Shipping COAST... Sprinkling System, Details § 76.25-20 Pressure tank. (a) A pressure tank or other suitable means shall be... shall be carried in the tank to fill the piping of the largest zone, and in addition, force out at least...

  2. 46 CFR 76.25-20 - Pressure tank.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 3 2013-10-01 2013-10-01 false Pressure tank. 76.25-20 Section 76.25-20 Shipping COAST... Sprinkling System, Details § 76.25-20 Pressure tank. (a) A pressure tank or other suitable means shall be... shall be carried in the tank to fill the piping of the largest zone, and in addition, force out at least...

  3. 46 CFR 76.25-20 - Pressure tank.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 3 2014-10-01 2014-10-01 false Pressure tank. 76.25-20 Section 76.25-20 Shipping COAST... Sprinkling System, Details § 76.25-20 Pressure tank. (a) A pressure tank or other suitable means shall be... shall be carried in the tank to fill the piping of the largest zone, and in addition, force out at least...

  4. Development of a High Level Waste Tank Inspection System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Appel, D.K.; Loibl, M.W.; Meese, D.C.

    1995-03-21

    The Westinghouse Savannah River Technology Center was requested by it`s sister site, West Valley Nuclear Service (WVNS), to develop a remote inspection system to gather wall thickness readings of their High Level Waste Tanks. WVNS management chose to take a proactive approach to gain current information on two tanks t hat had been in service since the early 70`s. The tanks contain high level waste, are buried underground, and have only two access ports to an annular space between the tank and the secondary concrete vault. A specialized remote system was proposed to provide both a visual surveillance and ultrasonicmore » thickness measurements of the tank walls. A magnetic wheeled crawler was the basis for the remote delivery system integrated with an off-the-shelf Ultrasonic Data Acquisition System. A development program was initiated for Savannah River Technology Center (SRTC) to design, fabricate, and test a remote system based on the Crawler. The system was completed and involved three crawlers to perform the needed tasks, an Ultrasonic Crawler, a Camera Crawler, and a Surface Prep Crawler. The crawlers were computer controlled so that their operation could be done remotely and their position on the wall could be tracked. The Ultrasonic Crawler controls were interfaced with ABB Amdata`s I-PC, Ultrasonic Data Acquisition System so that thickness mapping of the wall could be obtained. A second system was requested by Westinghouse Savannah River Company (WSRC), to perform just ultrasonic mapping on their similar Waste Storage Tanks; however, the system needed to be interfaced with the P-scan Ultrasonic Data Acquisition System. Both remote inspection systems were completed 9/94. Qualifications tests were conducted by WVNS prior to implementation on the actual tank and tank development was achieved 10/94. The second inspection system was deployed at WSRC 11/94 with success, and the system is now in continuous service inspecting the remaining high level waste tanks

  5. 7 CFR 58.512 - Cheese vats or tanks.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Cheese vats or tanks. 58.512 Section 58.512 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....512 Cheese vats or tanks. (a) Cheese vats or tanks shall meet the requirements of § 58.416. When...

  6. 7 CFR 58.512 - Cheese vats or tanks.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Cheese vats or tanks. 58.512 Section 58.512 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....512 Cheese vats or tanks. (a) Cheese vats or tanks shall meet the requirements of § 58.416. When...

  7. Justification of the estimation technique for the technical condition of the tank with inadmissible imperfections in the wall shape

    NASA Astrophysics Data System (ADS)

    Chepur, Petr; Tarasenko, Alexander; Gruchenkova, Alesya

    2017-10-01

    The paper has its focus on the problem of estimating the stress-strain state of the vertical steel tanks with the inadmissible geometric imperfections in the wall shape. In the paper, the authors refer to an actual tank to demonstrate that the use of certain design schemes can lead to the raw errors and, accordingly, to the unreliable results. Obviously, these design schemes cannot be based on when choosing the real repair technologies. For that reason, authors performed the calculations of the tank removed out of service for the repair, basing on the developed finite-element model of the VST-5000 tank with a conical roof. The proposed approach was developed for the analysis of the SSS (stress-strain state) of a tank having geometric imperfections of the wall shape. Based on the work results, the following was proposed: to amend the Annex A methodology “Method for calculating the stress-strain state of the tank wall during repair by lifting the tank and replacing the wall metal structures” by inserting the requirement to compulsory consider the actual stiffness of the VST entire structure and its roof when calculating the structure stress-strain state.

  8. Provision of out-of-hours interventional radiology services in the London strategic health authority.

    PubMed

    Illing, R O; Clark, C L Ingham; Allum, C

    2010-04-01

    To review the provision of out-of-hours interventional radiology (IR) services in the London Strategic Health Authority (SHA). All 29 acute hospitals in the London SHA were contacted between November 2008 and January 2009. A questionnaire based on the Royal College of Radiologists (RCR) guidelines assessed the provision of out-of-hours IR services. An "ad-hoc" service was defined as on-call provision where not all the radiologists could perform intervention: If IR was required out of hours, an interventionalist came in when off-duty or the patient was transferred. Seventeen out of the 29 (59%) hospitals provided ad-hoc out-of-hours services, eight (28%) provided a 24-hour rota, and four (14%) provide no out-of-hours cover. No ad-hoc service had formal transfer arrangements to a centre providing a 24h service. Only two hospitals providing a 24h service had six radiologists on the rota. Strategic planning for out-of-hours IR across London is recommended. This is likely to be welcomed by the hospitals involved, allowing informal arrangements to be formalized, and collaboration to provide comprehensive regional networks, provided appropriate funding is made available. A national audit is recommended; it is unlikely these findings are unique to London.

  9. 49 CFR 172.331 - Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. 172.331 Section 172.331 Transportation Other Regulations... packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. (a) Each person...

  10. 49 CFR 172.331 - Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. 172.331 Section 172.331 Transportation Other Regulations... packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. (a) Each person...

  11. 49 CFR 172.331 - Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. 172.331 Section 172.331 Transportation Other Regulations... packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. (a) Each person...

  12. 49 CFR 172.331 - Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. 172.331 Section 172.331 Transportation Other Regulations... packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. (a) Each person...

  13. 49 CFR 172.331 - Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Bulk packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. 172.331 Section 172.331 Transportation Other Regulations... packagings other than portable tanks, cargo tanks, tank cars and multi-unit tank car tanks. (a) Each person...

  14. Idaho out-of-service verification field operational test

    DOT National Transportation Integrated Search

    2000-02-01

    The Out-of-Service Verification Field Operational Test Project was initiated in 1994. The purpose of the project was to test the feasibility of using sensors and a computerized tracking system to augment the ability of inspectors to monitor and contr...

  15. [Psychiatric treatment of deliberate self-harm in the out-of-hours services].

    PubMed

    Walby, Fredrik A; Ness, Ewa

    2009-04-30

    Patients who harm themselves are often considered difficult to treat. There are no evidence-based approaches available for the emergency setting. General practitioners should nevertheless be able to offer interventions directed towards emotional needs in self-harm patients. In this article we suggest how to intervene in such situations. Based on experience from Oslo psychiatric out-of-hours service and with elements from Dialectic Behavioural Therapy, we present a five-step model for treatment of these patients in an out-of-hours service within the primary health care services. The aim of this model is to bring the patient out of the acute crisis and to arrange for further treatment. Assessment, validation or confirmation, problem-solving, avoiding unnecessary hospitalisation, and focus on continuing established treatment, are important elements in the proposed intervention. This can all be carried out in 60 - 90 min. The model may be suitable for training general practitioners to meet and care for patients with self-harm behaviour in the out-hours-services. We have positive experience with the intervention, but systematic research is necessary to assess the effect of the model.

  16. 37. DETAIL OF CYANIDE LEACHING TANK DRAIN DOOR AND PIPING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    37. DETAIL OF CYANIDE LEACHING TANK DRAIN DOOR AND PIPING SYSTEM. NOTE SPIGOT UNDER BOARD AT UPPER LEFT INSERTS INTO HOLE IN PIPE AT BOTTOM OF FRAME. CYANIDE SOLUTION WAS PUMPED INTO THE TANKS AND THE PREGNANT SOLUTION DRAINED OUT OF THE TANKS THROUGH THIS PIPE, AND BACK INTO A SEPARATE HOLDING TANK ON THE EAST SIDE OF THE MILL. TAILINGS WERE REMOVED FROM THE TANKS THROUGH THE ROUND DRAIN DOOR IN THE BOTTOM OF THE TANK (MISSING) SEEN AT TOP CENTER. - Skidoo Mine, Park Route 38 (Skidoo Road), Death Valley Junction, Inyo County, CA

  17. The Kara and Ust-Kara impact structures (USSR) and their relevance to the K/T boundary event

    NASA Technical Reports Server (NTRS)

    Koeberl, Christian; Nazarov, M. A.; Harrison, T. M.; Sharpton, V. L.; Murali, A. V.; Burke, K.

    1988-01-01

    The Kara and Ust-Kara craters are twin impact structures situated at about 69 deg 10 min N; 65 deg 00 min E at the Kara Sea. For Kara a diameter of about 55 km would be a very conservative estimate, and field observations indicate a maximum current diameter of about 60 km. The diameter of Ust-Kara has to be larger than 16 km. A better estimate might be 25 km but in all likelihood it is even larger. Suevites and impactites from the Kara area have been known since the beginning of the century, but had been misidentified as glacial deposits. Only about 15 years ago the impact origin of the two structures was demonstrated, following the recognition of shock metamorphism in the area. The composition of the target rocks is mirrored by the composition of the clasts within the suevites. In the southern part of Kara, Permian shales and limestones are sometimes accompanied by diabasic dykes, similar to in the central uplift. Due to the high degree of shock metamorphism the shocked magmatic rocks are not easily identified, although most of them seem to be of diabasic or dioritic composition. The impact melts (tagamites) are grey to dark grey fine grained crystallized rocks showing very fine mineral components and are the product of shock-melting with later recrystallization. The impact glasses show a layered structure, inclusions, and vesicles, and have colors ranging from translucent white over brown and grey to black. A complete geochemical characterization of the Kara and Ust-Kara impact craters was attempted by analyzing more than 40 samples of target rocks, shocked rocks, suevites, impact melts, and impact glasses for major and trace elements.

  18. 40 CFR 280.21 - Upgrading of existing UST systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... sound and free of corrosion holes prior to installing the cathodic protection system; or (ii) The tank... for corrosion holes by conducting two (2) tightness tests that meet the requirements of § 280.43(c... operation of the cathodic protection system; or (iv) The tank is assessed for corrosion holes by a method...

  19. 40 CFR 280.21 - Upgrading of existing UST systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... sound and free of corrosion holes prior to installing the cathodic protection system; or (ii) The tank... for corrosion holes by conducting two (2) tightness tests that meet the requirements of § 280.43(c... operation of the cathodic protection system; or (iv) The tank is assessed for corrosion holes by a method...

  20. [Study on the quantitative estimation method for VOCs emission from petrochemical storage tanks based on tanks 4.0.9d model].

    PubMed

    Li, Jing; Wang, Min-Yan; Zhang, Jian; He, Wan-Qing; Nie, Lei; Shao, Xia

    2013-12-01

    VOCs emission from petrochemical storage tanks is one of the important emission sources in the petrochemical industry. In order to find out the VOCs emission amount of petrochemical storage tanks, Tanks 4.0.9d model is utilized to calculate the VOCs emission from different kinds of storage tanks. VOCs emissions from a horizontal tank, a vertical fixed roof tank, an internal floating roof tank and an external floating roof tank were calculated as an example. The consideration of the site meteorological information, the sealing information, the tank content information and unit conversion by using Tanks 4.0.9d model in China was also discussed. Tanks 4.0.9d model can be used to estimate VOCs emissions from petrochemical storage tanks in China as a simple and highly accurate method.

  1. Lifecycle Verification of Tank Liner Polymers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anovitz, Lawrence; Smith, Barton

    2014-03-01

    This report describes a method that was developed for the purpose of assessing the durability of thermoplastic liners used in a Type IV hydrogen storage tank during the tank s expected service life. In the method, a thermoplastic liner specimen is cycled between the maximum and minimum expected working temperatures while it is differentially pressurized with high-pressure hydrogen gas. The number of thermal cycling intervals corresponds to those expected within the tank s design lifetime. At prescribed intervals, hydrogen permeation measurements are done in situ to assess the ability of the liner specimen to maintain its hydrogen barrier properties andmore » to model its permeability over the tank lifetime. Finally, the model is used to assess whether the steady-state leakage rate in the tank could potentially exceed the leakage specification for hydrogen fuel cell passenger vehicles. A durability assessment was performed on a specimen of high-density polyethylene (HDPE) that is in current use as a tank liner. Hydrogen permeation measurements were performed on several additional tank liner polymers as well as novel polymers proposed for use as storage tank liners and hydrogen barrier materials. The following technical barriers from the Fuel Cell Technologies Program MYRDD were addressed by the project: D. Durability of on-board storage systems lifetime of at least 1500 cycles G. Materials of construction vessel containment that is resistant to hydrogen permeation M. Lack of Tank Performance Data and Understanding of Failure Mechanisms And the following technical targets1 for on-board hydrogen storage systems R&D were likewise addressed: Operational cycle life (1/4 tank to full) FY 2017: 1500 cycles; Ultimate: 1500 cycles Environmental health & safety Permeation and leakage: Meets or exceeds applicable standards Loss of useable H2: FY 2017: 0.05 g/h/kg H2; Ultimate: 0.05 g/h/kg H2« less

  2. Leaking Underground Storage Tanks and Environmental Injustice: Is There a Hidden and Unequal Threat to Public Health in South Carolina?

    PubMed Central

    Wilson, Sacoby; Zhang, Hongmei; Burwell, Kristen; Samantapudi, Ashok; Dalemarre, Laura; Jiang, Chengsheng; Rice, LaShanta; Williams, Edith; Naney, Charles

    2014-01-01

    There are approximately 590,000 underground storage tanks (USTs) nationwide that store petroleum or hazardous substances. Many of these tanks are leaking, which may increase the risk of exposure to contaminants that promote health problems in host neighborhoods. Within this study, we assessed disparities in the spatial distribution of leaking underground storage tanks (LUSTs) based on socioeconomic status (SES) and race/ethnicity in South Carolina (SC). Chi-square tests were used to evaluate the difference in the proportion of populations who host a LUST compared to those not hosting a LUST for all sociodemographic factors. Linear regression models were applied to examine the association of distance to the nearest LUST with relevant sociodemographic measures. As percent black increased, the distance (both in kilometers and miles) to the nearest LUST decreased. Similar results were observed for percent poverty, unemployment, persons with less than a high school education, blacks in poverty, and whites in poverty. Furthermore, chi-square tests indicated that blacks or non-whites or people with low SES were more likely to live in LUST host areas than in non-host areas. As buffer distance increased, percent black and non-white decreased. SES variables demonstrated a similar inverse relationship. Overall, burden disparities exist in the distribution of LUSTs based on race/ethnicity and SES in SC. PMID:24729829

  3. 49 CFR 173.318 - Cryogenic liquids in cargo tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... than two times the tank's design pressure. (6) Maximum filling rate. (i) For a tank used in oxygen and... the design service temperature of the packaging. (2) A cargo tank may not be loaded with any material... two independent pressure relief systems which are not connected in series, namely: (A) A primary...

  4. 49 CFR 173.318 - Cryogenic liquids in cargo tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... than two times the tank's design pressure. (6) Maximum filling rate. (i) For a tank used in oxygen and... the design service temperature of the packaging. (2) A cargo tank may not be loaded with any material... two independent pressure relief systems which are not connected in series, namely: (A) A primary...

  5. 49 CFR 173.318 - Cryogenic liquids in cargo tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... than two times the tank's design pressure. (6) Maximum filling rate. (i) For a tank used in oxygen and... the design service temperature of the packaging. (2) A cargo tank may not be loaded with any material... two independent pressure relief systems which are not connected in series, namely: (A) A primary...

  6. 49 CFR 173.318 - Cryogenic liquids in cargo tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... than two times the tank's design pressure. (6) Maximum filling rate. (i) For a tank used in oxygen and... the design service temperature of the packaging. (2) A cargo tank may not be loaded with any material... two independent pressure relief systems which are not connected in series, namely: (A) A primary...

  7. 49 CFR 195.307 - Pressure testing aboveground breakout tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... aboveground breakout tanks. (a) For aboveground breakout tanks built into API Specification 12F and first placed in service after October 2, 2000, pneumatic testing must be in accordance with section 5.3 of API Specification 12 F (incorporated by reference, see § 195.3). (b) For aboveground breakout tanks built to API...

  8. 49 CFR 195.307 - Pressure testing aboveground breakout tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... aboveground breakout tanks. (a) For aboveground breakout tanks built into API Specification 12F and first placed in service after October 2, 2000, pneumatic testing must be in accordance with section 5.3 of API Specification 12 F (incorporated by reference, see § 195.3). (b) For aboveground breakout tanks built to API...

  9. 49 CFR 195.307 - Pressure testing aboveground breakout tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... aboveground breakout tanks. (a) For aboveground breakout tanks built into API Specification 12F and first placed in service after October 2, 2000, pneumatic testing must be in accordance with section 5.3 of API Specification 12 F (incorporated by reference, see § 195.3). (b) For aboveground breakout tanks built to API...

  10. 49 CFR 195.307 - Pressure testing aboveground breakout tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... aboveground breakout tanks. (a) For aboveground breakout tanks built into API Specification 12F and first placed in service after October 2, 2000, pneumatic testing must be in accordance with section 5.3 of API Specification 12 F (incorporated by reference, see § 195.3). (b) For aboveground breakout tanks built to API...

  11. System for removing liquid waste from a tank

    DOEpatents

    Meneely, Timothy K.; Sherbine, Catherine A.

    1994-01-01

    A tank especially suited for nuclear applications is disclosed. The tank comprises a tank shell for protectively surrounding the liquid contained therein; an inlet positioned on the tank for passing a liquid into the tank; a sump positioned in an interior portion of the tank for forming a reservoir of the liquid; a sloped incline for resting the tank thereon and for creating a natural flow of the liquid toward the sump; a pump disposed adjacent the tank for pumping the liquid; and a pipe attached to the pump and extending into the sump for passing the liquid therethrough. The pump pumps the liquid in the sump through the pipe and into the pump for discharging the liquid out of the tank.

  12. System for removing liquid waste from a tank

    DOEpatents

    Meneely, T.K.; Sherbine, C.A.

    1994-04-26

    A tank especially suited for nuclear applications is disclosed. The tank comprises a tank shell for protectively surrounding the liquid contained therein; an inlet positioned on the tank for passing a liquid into the tank; a sump positioned in an interior portion of the tank for forming a reservoir of the liquid; a sloped incline for resting the tank thereon and for creating a natural flow of the liquid toward the sump; a pump disposed adjacent the tank for pumping the liquid; and a pipe attached to the pump and extending into the sump for passing the liquid there through. The pump pumps the liquid in the sump through the pipe and into the pump for discharging the liquid out of the tank. 2 figures.

  13. Organic chemical aging mechanisms: An annotated bibliography. Waste Tank Safety Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samuels, W.D.; Camaioni, D.M.; Nelson, D.A.

    1993-09-01

    An annotated bibliography has been compiled of the potential chemical and radiological aging mechanisms of the organic constituents (non-ferrocyanide) that would likely be found in the UST at Hanford. The majority of the work that has been conducted on the aging of organic chemicals used for extraction and processing of nuclear materials has been in conjunction with the acid or PUREX type processes. At Hanford the waste being stored in the UST has been stabilized with caustic. The aging factors that were used in this work were radiolysis, hydrolysis and nitrite/nitrate oxidation. The purpose of this work was two-fold: tomore » determine whether or not research had been or is currently being conducted on the species associated with the Hanford UST waste, either as a mixture or as individual chemicals or chemical functionalities, and to determine what areas of chemical aging need to be addressed by further research.« less

  14. 40 CFR 281.33 - Release detection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... equipped with release detection that detects a release within an hour by restricting or shutting off flow... designed to allow the contents of the pipe to drain back into the storage tank if the suction is released... UST systems must use interstitial monitoring within secondary containment of the tanks and the...

  15. 40 CFR 281.33 - Release detection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... equipped with release detection that detects a release within an hour by restricting or shutting off flow... designed to allow the contents of the pipe to drain back into the storage tank if the suction is released... UST systems must use interstitial monitoring within secondary containment of the tanks and the...

  16. 40 CFR 281.33 - Release detection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... equipped with release detection that detects a release within an hour by restricting or shutting off flow... designed to allow the contents of the pipe to drain back into the storage tank if the suction is released... UST systems must use interstitial monitoring within secondary containment of the tanks and the...

  17. [Vertical integration and contracting-out in generic hospital services in Spain].

    PubMed

    Puig-Junoy, J; Pérez-Sust, P

    2002-01-01

    This study examines the factors that influence make or buy decisions corresponding to four generic services (housekeeping, laundry, food services, and maintenance and security) in Spanish hospitals (3,160 transactions in 790 hospitals). The empirical estimation of a logistic model based on hospital utility maximization is presented. Factors included in the model are not only those related to transaction costs, but also those related to public intervention and the political dimension. A total of 55.7% of hospitals contracted-out at least one of the generic services. The services most frequently contracted-out were housekeeping and maintenance and security(45.1 and 32.5%, respectively). In contrast, the services (94.3% and 80.1%, respectively). Hospital size (economies of scale), measured by the number of beds, was one of the most important factors influencing make or buy decisions. We find evidence that economies of scale are related to a higher level of vertical integration, while specialization and for-profit objectives favor the decision to contract-out. The choice of organizational model for laundry services presents a different pattern from that of the other three services. Empirical results show that some asset specificity could be present in laundry services.

  18. Anticipating Environmental Impacts of Future Fuels

    EPA Science Inventory

    Automotive fuels are composed of hundreds of compounds and the formulations aren’t uniform; they vary geographically and seasonally and sometimes specifically in response to regulatory requirements. As a result, very few state underground storage tank (UST) regulators know what i...

  19. 49 CFR 172.330 - Tank cars and multi-unit tank car tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Tank cars and multi-unit tank car tanks. 172.330..., TRAINING REQUIREMENTS, AND SECURITY PLANS Marking § 172.330 Tank cars and multi-unit tank car tanks. (a... material— (1) In a tank car unless the following conditions are met: (i) The tank car must be marked on...

  20. 49 CFR 172.330 - Tank cars and multi-unit tank car tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Tank cars and multi-unit tank car tanks. 172.330..., TRAINING REQUIREMENTS, AND SECURITY PLANS Marking § 172.330 Tank cars and multi-unit tank car tanks. (a... material— (1) In a tank car unless the following conditions are met: (i) The tank car must be marked on...

  1. 49 CFR 172.330 - Tank cars and multi-unit tank car tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Tank cars and multi-unit tank car tanks. 172.330..., TRAINING REQUIREMENTS, AND SECURITY PLANS Marking § 172.330 Tank cars and multi-unit tank car tanks. (a... material— (1) In a tank car unless the following conditions are met: (i) The tank car must be marked on...

  2. EVALUATION OF SOIL WASHING TECHNOLOGY: RESULTS OF BENCH SCALE EXPERIMENTS ON PETROLEUM FUELS CONTAMINATED SOILS - EPA/600/S2-91/023

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA) through its Risk Reduction Engineering Laboratory's Release Control Branch has undertaken research and development efforts to address the problem of leaking underground storage tanks (USTs). Under this effort, EPA is currently eva...

  3. Review of quantitative surveys of the length and stability of MTBE, TBA, and benzene plumes in groundwater at UST sites.

    PubMed

    Connor, John A; Kamath, Roopa; Walker, Kenneth L; McHugh, Thomas E

    2015-01-01

    Quantitative information regarding the length and stability condition of groundwater plumes of benzene, methyl tert-butyl ether (MTBE), and tert-butyl alcohol (TBA) has been compiled from thousands of underground storage tank (UST) sites in the United States where gasoline fuel releases have occurred. This paper presents a review and summary of 13 published scientific surveys, of which 10 address benzene and/or MTBE plumes only, and 3 address benzene, MTBE, and TBA plumes. These data show the observed lengths of benzene and MTBE plumes to be relatively consistent among various regions and hydrogeologic settings, with median lengths at a delineation limit of 10 µg/L falling into relatively narrow ranges from 101 to 185 feet for benzene and 110 to 178 feet for MTBE. The observed statistical distributions of MTBE and benzene plumes show the two plume types to be of comparable lengths, with 90th percentile MTBE plume lengths moderately exceeding benzene plume lengths by 16% at a 10-µg/L delineation limit (400 feet vs. 345 feet) and 25% at a 5-µg/L delineation limit (530 feet vs. 425 feet). Stability analyses for benzene and MTBE plumes found 94 and 93% of these plumes, respectively, to be in a nonexpanding condition, and over 91% of individual monitoring wells to exhibit nonincreasing concentration trends. Three published studies addressing TBA found TBA plumes to be of comparable length to MTBE and benzene plumes, with 86% of wells in one study showing nonincreasing concentration trends. © 2014 GSI Environmental Inc. Groundwater published by Wiley Periodicals, Inc. on behalf of National Ground Water Association.

  4. "Check This out": Assessing Customer Service at the Circulation Desk

    ERIC Educational Resources Information Center

    Long, Dallas

    2012-01-01

    The access services staff at Milner Library, Illinois State University, designed a customer service assessment to evaluate how effectively the department was carrying out its mission statement. Areas of assessment included the department's waiting times, helpfulness, and courtesy. The assessment activity focused on circulation services, which is…

  5. 49 CFR 174.63 - Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car tanks. 174.63 Section 174.63 Transportation Other....63 Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

  6. 49 CFR 174.63 - Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car tanks. 174.63 Section 174.63 Transportation Other....63 Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

  7. 49 CFR 174.63 - Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car tanks. 174.63 Section 174.63 Transportation Other....63 Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

  8. 49 CFR 174.63 - Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car tanks. 174.63 Section 174.63 Transportation Other....63 Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

  9. 49 CFR 174.63 - Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car tanks. 174.63 Section 174.63 Transportation Other....63 Portable tanks, IM portable tanks, IBCs, Large Packagings, cargo tanks, and multi-unit tank car...

  10. RECOMMENDATIONS FOR SAMPLING OF TANK 19 IN F TANK FARM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, S.; Shine, G.

    2009-12-14

    Representative sampling is required for characterization of the residual material in Tank 19 prior to operational closure. Tank 19 is a Type IV underground waste storage tank located in the F-Tank Farm. It is a cylindrical-shaped, carbon steel tank with a diameter of 85 feet, a height of 34.25 feet, and a working capacity of 1.3 million gallons. Tank 19 was placed in service in 1961 and initially received a small amount of low heat waste from Tank 17. It then served as an evaporator concentrate (saltcake) receiver from February 1962 to September 1976. Tank 19 also received the spentmore » zeolite ion exchange media from a cesium removal column that once operated in the Northeast riser of the tank to remove cesium from the evaporator overheads. Recent mechanical cleaning of the tank removed all mounds of material. Anticipating a low level of solids in the residual waste, Huff and Thaxton [2009] developed a plan to sample the waste during the final clean-up process while it would still be resident in sufficient quantities to support analytical determinations in four quadrants of the tank. Execution of the plan produced fewer solids than expected to support analytical determinations in all four quadrants. Huff and Thaxton [2009] then restructured the plan to characterize the residual separately in the North and the South regions: two 'hemispheres.' This document provides sampling recommendations to complete the characterization of the residual material on the tank bottom following the guidance in Huff and Thaxton [2009] to split the tank floor into a North and a South hemisphere. The number of samples is determined from a modification of the formula previously published in Edwards [2001] and the sample characterization data for previous sampling of Tank 19 described by Oji [2009]. The uncertainty is quantified by an upper 95% confidence limit (UCL95%) on each analyte's mean concentration in Tank 19. The procedure computes the uncertainty in analyte concentration as

  11. ANNUAL RADIOACTIVE WASTE TANK INSPECTION PROGRAM 2009

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    West, B.; Waltz, R.

    2010-06-21

    Aqueous radioactive wastes from Savannah River Site (SRS) separations and vitrification processes are contained in large underground carbon steel tanks. Inspections made during 2009 to evaluate these vessels and other waste handling facilities along with evaluations based on data from previous inspections are the subject of this report. The 2009 inspection program revealed that the structural integrity and waste confinement capability of the Savannah River Site waste tanks were maintained. All inspections scheduled per LWO-LWE-2008-00423, HLW Tank Farm Inspection Plan for 2009, were completed. All Ultrasonic measurements (UT) performed in 2009 met the requirements of C-ESG-00006, In-Service Inspection Program formore » High Level Waste Tanks, Rev. 1, and WSRC-TR-2002-00061, Rev.4. UT inspections were performed on Tank 29 and the findings are documented in SRNL-STI-2009-00559, Tank Inspection NDE Results for Fiscal Year 2009, Waste Tank 29. Post chemical cleaning UT measurements were made in Tank 6 and the results are documented in SRNL-STI-2009-00560, Tank Inspection NDE Results Tank 6, Including Summary of Waste Removal Support Activities in Tanks 5 and 6. A total of 6669 photographs were made and 1276 visual and video inspections were performed during 2009. Twenty-Two new leaksites were identified in 2009. The locations of these leaksites are documented in C-ESR-G-00003, SRS High Level Waste Tank Leaksite Information, Rev.4. Fifteen leaksites at Tank 5 were documented during tank wall/annulus cleaning activities. Five leaksites at Tank 6 were documented during tank wall/annulus cleaning activities. Two new leaksites were identified at Tank 19 during waste removal activities. Previously documented leaksites were reactivated at Tanks 5 and 12 during waste removal activities. Also, a very small amount of additional leakage from a previously identified leaksite at Tank 14 was observed.« less

  12. 7 CFR 58.416 - Cheese vats, tanks and drain tables.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Cheese vats, tanks and drain tables. 58.416 Section 58... Service 1 Equipment and Utensils § 58.416 Cheese vats, tanks and drain tables. (a) The vats, tanks and drain tables used for making cheese should be of metal construction with adequate jacket capacity for...

  13. 7 CFR 58.416 - Cheese vats, tanks and drain tables.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Cheese vats, tanks and drain tables. 58.416 Section 58... Service 1 Equipment and Utensils § 58.416 Cheese vats, tanks and drain tables. (a) The vats, tanks and drain tables used for making cheese should be of metal construction with adequate jacket capacity for...

  14. Cost Effective, Ultra Sensitive Groundwater Monitoring for Site Remediation and Management

    DTIC Science & Technology

    2015-05-01

    feasibility studies. ................... 30  Table 5. Compounds screened in the laboratory for IS2 sampling...tank SVOC semivolatile organic compound TCE trichloroethene TPH total petroleum hydrocarbon USEPA U.S. Environmental Protection Agency UST...underground storage tank V volt VOA volatile organic analysis VOC volatile organic compound Technical material contained in this report has

  15. Case Study in Corporate Memory Recovery: Hanford Tank Farms Miscellaneous Underground Waste Storage Tanks - 15344

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Washenfelder, D. J.; Johnson, J. M.; Turknett, J. C.

    In addition to managing the 177 underground waste storage tanks containing 212,000 m3 (56 million gal) of radioactive waste at the U. S. Department of Energy’s Hanford Site 200 Area Tank Farms, Washington River Protection Solutions LLC is responsible for managing numerous small catch tanks and special surveillance facilities. These are collectively known as “MUSTs” - Miscellaneous Underground Storage Tanks. The MUSTs typically collected drainage and flushes during waste transfer system piping changes; special surveillance facilities supported Tank Farm processes including post-World War II uranium recovery and later fission product recovery from tank wastes. Most were removed from service followingmore » deactivation of the single-shell tank system in 1980 and stabilized by pumping the remaining liquids from them. The MUSTs were isolated by blanking connecting transfer lines and adding weatherproofing to prevent rainwater entry. Over the next 30 years MUST operating records were dispersed into large electronic databases or transferred to the National Archives Regional Center in Seattle, Washington. During 2014 an effort to reacquire the historical bases for the MUSTs’ published waste volumes was undertaken. Corporate Memory Recovery from a variety of record sources allowed waste volumes to be initially determined for 21 MUSTs, and waste volumes to be adjusted for 37 others. Precursors and symptoms of Corporate Memory Loss were identified in the context of MUST records recovery.« less

  16. 14 CFR 27.971 - Fuel tank sump.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... must have a drainable sump with an effective capacity in any ground attitude to be expected in service... that in any ground attitude to be expected in service, water will drain from all parts of the tank to...

  17. 14. Interior view, grain tanks (bins). Barrel view of tunnel ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. Interior view, grain tanks (bins). Barrel view of tunnel for load-out belt conveyor system located below tanks. Square, numbered spouts gravity-feed grain from overhead bins onto belt. - Saint Anthony Elevator No. 3, 620 Malcom Avenue, Southeast, Minneapolis, Hennepin County, MN

  18. Lead Me Out Environmental Services, Inc. Information Sheet

    EPA Pesticide Factsheets

    Lead Me Out Environmental Services, Inc. (the Company) is located in New York, New York. The settlement involves abatement activities conducted at property constructed prior to 1978, located in Brooklyn, New York.

  19. The Ust'-Kamchatsk "Tsunami Earthquake" of 13 April 1923: A Slow Event and a Probable Landslide

    NASA Astrophysics Data System (ADS)

    Salaree, A.; Okal, E.

    2016-12-01

    Among the "tsunami earthquakes" having generated a larger tsunami than expected from their seismic magnitudes, the large aftershock of the great Kamchatka earthquake of 1923 remains an intriguing puzzle since waves reaching 11 m were reported by Troshin & Diagilev (1926), in the vicinity of the mouth of the Kamchatka River near the coastal settlement of Ust'-Kamchatsk. Our relocation attempts based on ISS-listed travel times would put the earthquake epicenter in Ozernoye Bay, North of the Kamchatka Peninsula, suggesting that it was triggered by stress transfer beyond the plate junction at the Kamchatka corner. Mantle magnitudes obtained from Golitsyn records at De Bilt suggest a long-period moment of 2-3 times 1027 dyn*cm, with a strong increase of moment with period, suggestive of a slow source. However, tsunami simulations based on resulting models of the earthquake source, both North and South of the Kamchatka Peninsula, fail to account for the reported run-up values. On the other hand, the model of an underwater landslide, which would have been triggered by the earthquake, can explain the general amplitude and distribution of reported run-up. This model is supported by the presence of steep bathymetry offshore of Ust'-Kamchatsk, near the area of discharge of the Kamchatka River, and the abundance of subaerial landslides along the nearby coasts of the Kamchatka Peninsula. While the scarcity of scientific data for this ancient earthquake, and of historical reports in a sparsely populated area, keep this interpretation tentative, this study contributes to improving our knowledge of the challenging family of "tsunami earthquakes".

  20. Fracture control method for composite tanks with load sharing liners

    NASA Technical Reports Server (NTRS)

    Bixler, W. D.

    1975-01-01

    The experimental program was based on the premise that the plastic sizing cycle, which each pressure vessel is subjected to prior to operation, acts as an effective proof test of the liner, screening out all flaws or cracks larger than a critical size. In doing so, flaw growth potential is available for cyclic operation at pressures less than the sizing pressure. Static fracture and cyclic life tests, involving laboratory type specimens and filament overwrapped tanks, were conducted on three liner materials: (1) 2219-T62 aluminum, (2) Inconel X750 STA, and (3) cryoformed 301 stainless steel. Variables included material condition, thickness, flaw size, flaw shape, temperature, sizing stress level, operating stress level and minimum-to-maximum operating stress ratio. From the empirical data base obtained, a procedure was established by which the service life of composite tanks with load sharing liners could be guaranteed with a high degree of confidence.

  1. Federal parity law associated with increased probability of using out-of-network substance use disorder treatment services.

    PubMed

    McGinty, Emma E; Busch, Susan H; Stuart, Elizabeth A; Huskamp, Haiden A; Gibson, Teresa B; Goldman, Howard H; Barry, Colleen L

    2015-08-01

    The Paul Wellstone and Pete Domenici Mental Health Parity and Addiction Equity Act of 2008 requires commercial insurers providing group coverage for substance use disorder services to offer benefits for those services at a level equal to those for medical or surgical benefits. Unlike previous parity policies instituted for federal employees and in individual states, the law extends parity to out-of-network services. We conducted an interrupted time-series analysis using insurance claims from large self-insured employers to evaluate whether federal parity was associated with changes in out-of-network treatment for 525,620 users of substance use disorder services. Federal parity was associated with an increased probability of using out-of-network services, an increased average number of out-of-network outpatient visits, and increased average total spending on out-of-network services among users of those services. Our findings were broadly consistent with the contention of federal parity proponents that extending parity to out-of-network services would broaden access to substance use disorder care obtained outside of plan networks. Project HOPE—The People-to-People Health Foundation, Inc.

  2. Increasing the endurance of electrodes of heating salt tanks

    NASA Astrophysics Data System (ADS)

    Kulikov, A. I.

    1997-05-01

    Electrodes used for heating, melting, and sustaining the requisite temperature regime in salt tanks for heat treatment of metals and alloys operate under severe conditions (heating to 1300°C, aggressive medium of the melts of salts of alkali and alkali-earth metals). This causes early failure of the electrodes, and the heat treatment unit is stopped for repair. For example, the design service life of electrodes for SVS 2.3/13I tanks is two months, but as a rule it does not exceed one month of continuous operation. The replacement of conventional low-carbon electrode steel (for example, of grade 10) by a more expensive heat- and corrosion-resistant steel has not proved effective but rather increased the cost of the electrodes and hence the cost of the produced parts. In this connection, it is interesting to get acquainted with works devoted to increasing the service life of salt-tank electrodes for heat treatment shops of machine-building and tool plants. The present paper describes such an attempt.

  3. Composite overwrapped metallic tanks

    NASA Technical Reports Server (NTRS)

    Caudill, C. L.; Kirlin, R. L.

    1972-01-01

    Work is reported for fabricating and testing the fiberglass overwrapped titanium pressure vessel for cryogenic service. Difficulties encountered in the tank liner fabrication phase involved explosive forming, vacuum annealing, chemical milling and electron beam welding. While each of these processes and the nondestructive test methods employed are normally considered to be individually reliable, the combination of poor material together with fabrication and development reversals prevented the full achievement of the desired end results. Eight tanks plus a prototype and tool proofing article were produced. Six of the vessels failed during the hydrostatic sizing operation. One of the remaining tanks was hydrostatically pressurized to burst and the other was pressurized repeatedly at 75 F from 100 psi to the operating pressure until failure occurred. As a result, it is not possible to draw firm conclusions as to the true value of the design concept due to the problems encountered in the program.

  4. UNDERSTANDING THE FATE OF PETROLEUM HYDROCARBONS IN THE SUBSURFACE ENVIRONMENT

    EPA Science Inventory

    Sinca a significant number of the two or more million underground storage tank (UST) systems used for petroleum products leak, their cleanup poses a major environmental challenge. Our understnading of the fate of petroleum hydrocarbons in the subsurface environment is critical t...

  5. Thermal Analysis of Reinforced Concrete Tank for Conditioning Wood by FEM Method

    NASA Astrophysics Data System (ADS)

    Błaszczyński, Tomasz; Babiak, Michał; Wielentejczyk, Przemysław

    2017-10-01

    The article introduces the analysis of a RC tank for conditioning wood carried out using the FEM (Finite Element Method). A temperature gradient distribution increase resulting from the influence of hot liquid filling the tank was defined. Values of gradients in border sections of the tank walls and the bottom were defined on the basis of the isotherm method. The obtained results were compared with empirical formulas from literature. Strength analyses were also carried out. Additionally, the problematic aspects of elongated monolithic tanks for liquids were introduced, especially regarding large temperature gradients and the means of necessary technical solutions. The use of the FEM method for designing engineering objects is, nowadays, an irreplaceable solution. In the case of the discussed tank, a spatial model of the construction mapping its actual performance was constructed in order to correctly estimate the necessary dimensions of wall and bottom sections, as well as reinforcement.

  6. IceTop tank response to muons

    NASA Astrophysics Data System (ADS)

    Demirörs, L.; Beimforde, M.; Eisch, J.; Madsen, J.; Niessen, P.; Spiczak, G.M.; Stoyanov, S.; Tilav, S

    The calibration of the surface air shower array of IceCube - IceTop is based on identifying and understanding the muon response of each IceTop tank. Special calibration runs are carried out throughout the year and are supplemented with austral season measurements with tagging telescope for vertical muons. The vertical equivalent muon (VEM) charge value of each tank is determined and monitored by keeping track of its variation with time and temperature. We also study muons that stop and decay in the tank. The energy spectrum of the electrons from muon decay (Michel spectrum) is well known with maximum energy of 53 MeV. This energy is usually deposited inside the tank and can also be used as a calibration tool. We use both these spectra and compare them to a Monte Carlo simulation to gain a better understanding of the tank properties.

  7. Simulation of Hanford Tank 241-C-106 Waste Release into Tank 241-Y-102

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    KP Recknagle; Y Onishi

    Waste stored in Hdord single-shell Tank 241-C-106 will be sluiced with a supernatant liquid from doubIe-shell Tank 241 -AY- 102 (AY-1 02) at the U.S. Department of Energy's Har@ord Site in Eastern Washington. The resulting slurry, containing up to 30 wtYo solids, will then be transferred to Tank AY-102. During the sluicing process, it is important to know the mass of the solids being transferred into AY- 102. One of the primary instruments used to measure solids transfer is an E+ densitometer located near the periphery of the tank at riser 15S. This study was undert.dcen to assess how wellmore » a densitometer measurement could represent the total mass of soiids transferred if a uniform lateral distribution was assumed. The study evaluated the C-1 06 slurry mixing and accumulation in Tank AY- 102 for the following five cases: Case 1: 3 wt'%0 slurry in 6.4-m AY-102 waste Case 2: 3 w-t% slurry in 4.3-m AY-102 waste Case 3: 30 wtYo slurry in 6.4-m AY-102 waste Case 4: 30 wt% slurry in 4.3-m AY-102 waste Case 5: 30 wt% slurry in 5. O-m AY-102 waste. The tirne-dependent, three-dimensional, TEMPEST computer code was used to simulate solid deposition and accumulation during the injection of the C-106 slurry into AY-102 through four injection nozzles. The TEMPEST computer code was applied previously to other Hanford tanks, AP-102, SY-102, AZ-101, SY-101, AY-102, and C-106, to model tank waste mixing with rotating pump jets, gas rollover events, waste transfer from one tank to another, and pump-out retrieval of the sluiced waste. The model results indicate that the solid depth accumulated at the densitometer is within 5% of the average depth accumulation. Thus the reading of the densitometer is expected to represent the total mass of the transferred solids reasonably well.« less

  8. Selected topics in railroad tank car safety research. Volume 1 : fatigue evaluation of prototype tank car head shield

    DOT National Transportation Integrated Search

    1978-08-01

    The characteristics of a prototype head shield for hazardous material tank cars were evaluated with respect to the maintenance of its structural integrity under normal service conditions. The primary concern was with the resistance to fatigue damage ...

  9. ANNUAL RADIOACTIVE WASTE TANK INSPECTION PROGRAM 2010

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    West, B.; Waltz, R.

    Aqueous radioactive wastes from Savannah River Site (SRS) separations and vitrification processes are contained in large underground carbon steel tanks. Inspections made during 2010 to evaluate these vessels and other waste handling facilities along with evaluations based on data from previous inspections are the subject of this report. The 2010 inspection program revealed that the structural integrity and waste confinement capability of the Savannah River Site waste tanks were maintained. All inspections scheduled per SRR-LWE-2009-00138, HLW Tank Farm Inspection Plan for 2010, were completed. Ultrasonic measurements (UT) performed in 2010 met the requirements of C-ESG-00006, In-Service Inspection Program for Highmore » Level Waste Tanks, Rev. 3, and WSRC-TR-2002-00061, Rev.6. UT inspections were performed on Tanks 30, 31 and 32 and the findings are documented in SRNL-STI-2010-00533, Tank Inspection NDE Results for Fiscal Year 2010, Waste Tanks 30, 31 and 32. A total of 5824 photographs were made and 1087 visual and video inspections were performed during 2010. Ten new leaksites at Tank 5 were identified in 2010. The locations of these leaksites are documented in C-ESR-G-00003, SRS High Level Waste Tank Leaksite Information, Rev.5. Ten leaksites at Tank 5 were documented during tank wall/annulus cleaning activities. None of these new leaksites resulted in a release to the environment. The leaksites were documented during wall cleaning activities and the waste nodules associated with the leaksites were washed away. Previously documented leaksites were reactivated at Tank 12 during waste removal activities.« less

  10. 46 CFR 169.234 - Integral fuel oil tank examinations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Integral fuel oil tank examinations. 169.234 Section 169... VESSELS Inspection and Certification Drydocking Or Hauling Out § 169.234 Integral fuel oil tank examinations. (a) Each fuel oil tank with at least one side integral to the vessel's hull and located within...

  11. 46 CFR 169.234 - Integral fuel oil tank examinations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Integral fuel oil tank examinations. 169.234 Section 169... VESSELS Inspection and Certification Drydocking Or Hauling Out § 169.234 Integral fuel oil tank examinations. (a) Each fuel oil tank with at least one side integral to the vessel's hull and located within...

  12. 46 CFR 169.234 - Integral fuel oil tank examinations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Integral fuel oil tank examinations. 169.234 Section 169... VESSELS Inspection and Certification Drydocking Or Hauling Out § 169.234 Integral fuel oil tank examinations. (a) Each fuel oil tank with at least one side integral to the vessel's hull and located within...

  13. 46 CFR 169.234 - Integral fuel oil tank examinations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Integral fuel oil tank examinations. 169.234 Section 169... VESSELS Inspection and Certification Drydocking Or Hauling Out § 169.234 Integral fuel oil tank examinations. (a) Each fuel oil tank with at least one side integral to the vessel's hull and located within...

  14. Contracting out of health services in developing countries.

    PubMed

    McPake, B; Banda, E E

    1994-03-01

    Contracting out is emerging as a common policy issue in a number of developing countries. The theoretical case for contracting out suggests many advantages in combining public finance with private provision. However, practical difficulties such as those of ensuring that competition takes place between potential contractors, that competition leads to efficiency and that contracts and the process of contracting are effectively managed, suggest that such advantages may not always be realized. Most countries are likely only to contemplate restricted contracting of small-scale non-clinical services in the short term. Prerequisites of more extensive models appear to be the development of information systems and human resources to that end. Some urban areas of larger countries may have the existing preconditions for more successful large-scale contracting.

  15. 46 CFR 154.1831 - Persons in charge of transferring liquid cargo in bulk or preparing cargo tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... in bulk or a cool-down, warm-up, gas-free, or air-out of each cargo tank; (2) Each transfer of liquid cargo in bulk, and each cool-down, warm-up, gas-free, or air-out of a cargo tank, is supervised by a... in bulk or a cool-down, warm-up, gas-free, or air-out of a cargo tank possesses the qualifications...

  16. 46 CFR 154.1831 - Persons in charge of transferring liquid cargo in bulk or preparing cargo tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... in bulk or a cool-down, warm-up, gas-free, or air-out of each cargo tank; (2) Each transfer of liquid cargo in bulk, and each cool-down, warm-up, gas-free, or air-out of a cargo tank, is supervised by a... in bulk or a cool-down, warm-up, gas-free, or air-out of a cargo tank possesses the qualifications...

  17. 46 CFR 154.1831 - Persons in charge of transferring liquid cargo in bulk or preparing cargo tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... in bulk or a cool-down, warm-up, gas-free, or air-out of each cargo tank; (2) Each transfer of liquid cargo in bulk, and each cool-down, warm-up, gas-free, or air-out of a cargo tank, is supervised by a... in bulk or a cool-down, warm-up, gas-free, or air-out of a cargo tank possesses the qualifications...

  18. 46 CFR 154.1831 - Persons in charge of transferring liquid cargo in bulk or preparing cargo tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... in bulk or a cool-down, warm-up, gas-free, or air-out of each cargo tank; (2) Each transfer of liquid cargo in bulk, and each cool-down, warm-up, gas-free, or air-out of a cargo tank, is supervised by a... in bulk or a cool-down, warm-up, gas-free, or air-out of a cargo tank possesses the qualifications...

  19. Cost-Effective, Ultra-Sensitive Groundwater Monitoring for Site Remediation and Management

    DTIC Science & Technology

    2015-05-01

    Example anion concentrations in groundwater used for feasibility studies. ................... 30 Table 5. Compounds screened in the laboratory for IS2...phase extraction ST storage tank SVOC semivolatile organic compound TCE trichloroethene TPH total petroleum hydrocarbon USEPA U.S. Environmental...Protection Agency UST underground storage tank V volt VOA volatile organic analysis VOC volatile organic compound Technical material

  20. Council tax valuation bands and contacts with a GP out-of-hours service.

    PubMed

    Beale, Norman; Taylor, Gordon; Gwynne, Mark; Peart, Carole

    2006-04-01

    UK GPs are no longer responsible for the organisation of out-of-hours care for their patients, but resources remains capitation-based. This cross-sectional study tests whether council tax valuation bands can predict the demand for such services. All out-of-hours contacts made by patients in North Wiltshire over 4 months were classified by council tax band; frequencies compared with official population statistics. Council tax band predicts out-of-hours GP workload irrespective of age and sex: the more modest the home, the higher the GP contact rate. It may prove more difficult to sustain out-of-hours services in deprived parts of the UK.

  1. Complementary health insurance, out- of- pocket expenditures, and health services utilization: A population- based survey.

    PubMed

    Homaie Rad, Enayatollah; Kavosi, Zahra; Moghadamnia, Mohammad Taghi; Arefnezhad, Masoud; Arefnezhad, Masoumeh; Felezi Nasiri, Banfashe

    2017-01-01

    Background: Studies have shown that people using complementary health insurances have more access to health services than others. In the present study, we aimed at finding the differences between out- of- pocket payments and health service utilizations in complementary health insurances (CHIs) users and nonusers. Methods: Propensity score matching was used to compare the 2 groups. First, confounder variables were identified, and then propensity score matching was used to compare out- of- pocket expenditures with dental, general physician, hospital inpatient, emergency services, nursing, midwifery, laboratory services, specialists and rehabilitation services utilization. Results: Our results revealed no significant differences between the 2 groups in out- of- pocket health expenditures. Also, the specialist visits, inpatient services at the hospital, and dental services were higher in people who used CHIs compared to nonusers. Conclusion: People did not change their budget share for health care services after using CHIs. The payments were equal for people who were not CHIs users due to the increase in the quantity of the services.

  2. Developing NDE Techniques for Large Cryogenic Tanks

    NASA Technical Reports Server (NTRS)

    Parker, Don; Starr, Stan; Arens, Ellen

    2011-01-01

    The Shuttle Program requires very large cryogenic ground storage tanks in which to store liquid oxygen and hydrogen. The existing Pads A and B Launch Complex-39 tanks, which will be passed onto future launch programs, are 45 years old and have received minimal refurbishment and only external inspections over the years. The majority of the structure is inaccessible without a full system drain of cryogenic liquid and granular insulation in the annular region. It was previously thought that there was a limit to the number of temperature cycles that the tanks could handle due to possible insulation compaction before undergoing a costly and time consuming complete overhaul; therefore the tanks were not drained and performance issues with these tanks, specifically the Pad B liquid hydrogen tank, were accepted. There is a needind an opportunity, as the Shuttle program ends and work to upgrade the launch pads progresses, to develop innovative non-destructive evaluation (NDE) techniques to analyze the current tanks. Techniques are desired that can aid in determining the extent of refurbishment required to keep the tanks in service for another 20+ years. A nondestructive technique would also be a significant aid in acceptance testing of new and refurbished tanks, saving significant time and money, if corrective actions can be taken before cryogen is introduced to the systems.

  3. 46 CFR 31.10-24 - Integral fuel oil tank examinations-T/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... tanks cleaned out and gas freed as necessary to permit internal examination of the tank or tanks... of each vessel during an internal structural examination at intervals not to exceed five years. (b... inspector is able to determine by external examination that the general condition of the tanks is...

  4. ANNUAL RADIOACTIVE WASTE TANK INSPECTION PROGRAM - 2011

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    West, B.; Waltz, R.

    2012-06-21

    Aqueous radioactive wastes from Savannah River Site (SRS) separations and vitrification processes are contained in large underground carbon steel tanks. Inspections made during 2011 to evaluate these vessels and other waste handling facilities along with evaluations based on data from previous inspections are the subject of this report. The 2011 inspection program revealed that the structural integrity and waste confinement capability of the Savannah River Site waste tanks were maintained. All inspections scheduled per SRR-LWE-2011-00026, HLW Tank Farm Inspection Plan for 2011, were completed. Ultrasonic measurements (UT) performed in 2011 met the requirements of C-ESR-G-00006, In-Service Inspection Program for Highmore » Level Waste Tanks, Rev. 3, and WSRC-TR-2002-00061, Rev.6. UT inspections were performed on Tanks 25, 26 and 34 and the findings are documented in SRNL-STI-2011-00495, Tank Inspection NDE Results for Fiscal Year 2011, Waste Tanks 25, 26, 34 and 41. A total of 5813 photographs were made and 835 visual and video inspections were performed during 2011. A potential leaksite was discovered at Tank 4 during routine annual inspections performed in 2011. The new crack, which is above the allowable fill level, resulted in no release to the environment or tank annulus. The location of the crack is documented in C-ESR-G-00003, SRS High Level Waste Tank Leaksite Information, Rev.6.« less

  5. Floating baffle to improve efficiency of liquid transfer from tanks

    NASA Technical Reports Server (NTRS)

    Howard, F. S. (Inventor)

    1973-01-01

    A floating baffle is described which rides up and down on a vertical shaft over a drain in a tank as the liquid level within the tank varies. When the baffle is in the raised position, the liquid is allowed to flow out of the drain at an unrestricted rate. When the baffle is in the lowered position, pull-through of air or gas that is above the liquid is presented, which would interfere and reduce the flow of liquid from the tank.

  6. 40 CFR 280.108 - Substitution of financial assurance mechanisms by owner or operator.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... alternate financial assurance mechanisms as specified in this subpart, provided that at all times he... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Substitution of financial assurance... OWNERS AND OPERATORS OF UNDERGROUND STORAGE TANKS (UST) Financial Responsibility § 280.108 Substitution...

  7. 49 CFR 180.519 - Periodic retest and inspection of tank cars other than single-unit tank car tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Periodic retest and inspection of tank cars other than single-unit tank car tanks. 180.519 Section 180.519 Transportation Other Regulations Relating to... of Tank Cars § 180.519 Periodic retest and inspection of tank cars other than single-unit tank car...

  8. Hydrodynamics of octagonal culture tanks with Cornell-type dual-drain system

    USDA-ARS?s Scientific Manuscript database

    Large culture tanks of several hundred or thousand m3 size are generally encouraged for economic advantages in Recirculation Aquaculture Systems (RAS). Out of numerous possibilities in designing the inlet and outlet configurations in octagonal culture tanks, the inlet pipes near the corner walls and...

  9. Polymeric hydrogen diffusion barrier, high-pressure storage tank so equipped, method of fabricating a storage tank and method of preventing hydrogen diffusion

    DOEpatents

    Lessing, Paul A [Idaho Falls, ID

    2008-07-22

    An electrochemically active hydrogen diffusion barrier which comprises an anode layer, a cathode layer, and an intermediate electrolyte layer, which is conductive to protons and substantially impermeable to hydrogen. A catalytic metal present in or adjacent to the anode layer catalyzes an electrochemical reaction that converts any hydrogen that diffuses through the electrolyte layer to protons and electrons. The protons and electrons are transported to the cathode layer and reacted to form hydrogen. The hydrogen diffusion barrier is applied to a polymeric substrate used in a storage tank to store hydrogen under high pressure. A storage tank equipped with the electrochemically active hydrogen diffusion barrier, a method of fabricating the storage tank, and a method of preventing hydrogen from diffusing out of a storage tank are also disclosed.

  10. Polymeric hydrogen diffusion barrier, high-pressure storage tank so equipped, method of fabricating a storage tank and method of preventing hydrogen diffusion

    DOEpatents

    Lessing, Paul A.

    2004-09-07

    An electrochemically active hydrogen diffusion barrier which comprises an anode layer, a cathode layer, and an intermediate electrolyte layer, which is conductive to protons and substantially impermeable to hydrogen. A catalytic metal present in or adjacent to the anode layer catalyzes an electrochemical reaction that converts any hydrogen that diffuses through the electrolyte layer to protons and electrons. The protons and electrons are transported to the cathode layer and reacted to form hydrogen. The hydrogen diffusion barrier is applied to a polymeric substrate used in a storage tank to store hydrogen under high pressure. A storage tank equipped with the electrochemically active hydrogen diffusion barrier, a method of fabricating the storage tank, and a method of preventing hydrogen from diffusing out of a storage tank are also disclosed.

  11. RECOMMENDATIONS FOR SAMPLING OF TANK 18 IN F TANK FARM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shine, G.

    2009-12-14

    Representative sampling is required for characterization of the residual floor material in Tank 18 prior to operational closure. Tank 18 is an 85-foot diameter, 34-foot high carbon steel tank with nominal operating volume of 1,300,000 gallons. It is a Type IV tank, and has been in service storing radioactive materials since 1959. Recent mechanical cleaning of the tank removed all mounds of material. Anticipating a low level of solids in the residual material, Huff and Thaxton [2009] developed a plan to sample the material during the final clean-up process while it would still be resident in sufficient quantities to supportmore » analytical determinations in four quadrants of the tank. Execution of the plan produced fewer solids than expected to support analytical determinations in all four quadrants. Huff and Thaxton [2009] then restructured the plan to characterize the residual floor material separately in the North and the South regions: two 'hemispheres.' This document provides sampling recommendations to complete the characterization of the residual material on the tank bottom following the guidance in Huff and Thaxton [2009] to split the tank floor into a North and a South hemisphere. The number of samples is determined from a modification of the formula previously published in Edwards [2001] and the sample characterization data for previous sampling of Tank 18 described by Oji [2009]. The uncertainty is quantified by an upper 95% confidence limit (UCL95%) on each analyte's mean concentration in Tank 18. The procedure computes the uncertainty in analyte concentration as a function of the number of samples, and the final number of samples is determined when the reduction in the uncertainty from an additional sample no longer has a practical impact on results. The characterization of the full suite of analytes in the North hemisphere is currently supported by a single Mantis rover sample obtained from a compact region near the center riser. A floor scrape

  12. Parvulescu Revisited: Small Tank Acoustics for Bioacousticians.

    PubMed

    Rogers, Peter H; Hawkins, Anthony D; Popper, Arthur N; Fay, Richard R; Gray, Michael D

    2016-01-01

    Researchers often perform hearing studies on fish in small tanks. The acoustic field in such a tank is considerably different from the acoustic field that occurs in the animal's natural environment. The significance of these differences is magnified by the nature of the fish's auditory system where either acoustic pressure (a scalar), acoustic particle velocity (a vector), or both may serve as the stimulus. It is essential for the underwater acoustician to understand the acoustics of small tanks to be able to carry out valid auditory research in the laboratory and to properly compare and interpret the results of others.

  13. Mitigating contaminant transport in utility installation.

    DOT National Transportation Integrated Search

    2003-01-01

    In recent years, the Virginia Department of Transportation (VDOT) has experienced problems with various forms of contamination (primarily from underground storage tanks, USTs) migrating into its right-of-way. In many cases VDOT has had to install cul...

  14. 27 CFR 24.230 - Examination of tank car or tank truck.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Examination of tank car or... TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL WINE Spirits § 24.230 Examination of tank car or tank truck. Upon arrival of a tank car or tank truck at the bonded wine premises, the proprietor shall...

  15. 27 CFR 24.230 - Examination of tank car or tank truck.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Examination of tank car or... TRADE BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL WINE Spirits § 24.230 Examination of tank car or tank truck. Upon arrival of a tank car or tank truck at the bonded wine premises, the proprietor shall...

  16. 27 CFR 24.230 - Examination of tank car or tank truck.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Examination of tank car or... TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS WINE Spirits § 24.230 Examination of tank car or tank truck. Upon arrival of a tank car or tank truck at the bonded wine premises, the proprietor shall...

  17. 27 CFR 24.230 - Examination of tank car or tank truck.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Examination of tank car or... TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS WINE Spirits § 24.230 Examination of tank car or tank truck. Upon arrival of a tank car or tank truck at the bonded wine premises, the proprietor shall...

  18. 27 CFR 24.230 - Examination of tank car or tank truck.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Examination of tank car or... TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS WINE Spirits § 24.230 Examination of tank car or tank truck. Upon arrival of a tank car or tank truck at the bonded wine premises, the proprietor shall...

  19. The Ins and Outs of Keeping US Service Jobs at Work

    DTIC Science & Technology

    2006-06-14

    out of the US and into Mexico, Honduras, and eventually Asia. Gregory Mankiw , former Economic Advisor to the President, in 2004 said, “More things are...Background 12 1.2 History of Economic Evolution 16 1.3 Dealing with Change 21 1.4 Preparing the Framework 22 Chapter 2...16 1-4 Economic Development 17 1-5 Service Sector Growth in Dollars 18 1-6 Service Sector Growth in Percent of GDP 19 1-7

  20. 40 CFR 280.99 - Letter of credit.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Letter of credit. 280.99 Section 280.99 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) TECHNICAL STANDARDS AND CORRECTIVE ACTION REQUIREMENTS FOR OWNERS AND OPERATORS OF UNDERGROUND STORAGE TANKS (UST) Financial Responsibility § 280.99...

  1. Optimization of armored spherical tanks for storage on the lunar surface

    NASA Technical Reports Server (NTRS)

    Bents, D. J.; Knight, D. A.

    1992-01-01

    A redundancy strategy for reducing micrometeroid armoring mass is investigated, with application to cryogenic reactant storage for a regenerative fuel cell (RFC) on the lunar surface. In that micrometeoroid environment, the cryogenic fuel must be protected from loss due to tank puncture. The tankage must have a sufficiently high probability of survival over the length of the mission so that the probability of system failure due to tank puncture is low compared to the other mission risk factors. Assuming that a single meteoroid penetration can cause a storage tank to lose its contents, two means are available to raise the probability of surviving micrometeoroid attack to the desired level. One can armor the tanks to a thickness sufficient to reduce probability of penetration of any tank to the desired level or add extra capacity in the form of spare tanks that results in survival of a given number out of the ensemble at the desired level. A combination of these strategies (armoring and redundancy) is investigated. The objective is to find the optimum combination which yields the lowest shielding mass per cubic meter of surviving fuel out of the original ensemble. The investigation found that, for the volumes of fuel associated with multikilowatt class cryo storage RFC's, and the armoring methodology and meteoroid models used, storage should be fragmented into small individual tanks. Larger installations (more fuel) pay less of a shielding penalty than small installations. For the same survival probability over the same time period, larger volumes will require less armoring mass per unit volume protected.

  2. 30 CFR 250.1006 - How must I decommission and take out of service a DOI pipeline?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... a DOI pipeline? 250.1006 Section 250.1006 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT... and Pipeline Rights-of-Way § 250.1006 How must I decommission and take out of service a DOI pipeline...) The table in this section lists the requirements if you take a DOI pipeline out of service: If you...

  3. 241-AY-101 Tank Construction Extent of Condition Review for Tank Integrity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnes, Travis J.; Gunter, Jason R.

    2013-08-26

    This report provides the results of an extent of condition construction history review for tank 241-AY-101. The construction history of tank 241-AY-101 has been reviewed to identify issues similar to those experienced during tank AY-102 construction. Those issues and others impacting integrity are discussed based on information found in available construction records, using tank AY-102 as the comparison benchmark. In tank 241-AY-101, the second double-shell tank constructed, similar issues as those with tank 241-AY-102 construction reoccurred. The overall extent of similary and affect on tank 241-AY-101 integrity is described herein.

  4. 241-AP Tank Farm Construction Extent of Condition Review for Tank Integrity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnes, Travis J.; Gunter, Jason R.; Reeploeg, Gretchen E.

    2014-04-04

    This report provides the results of an extent of condition construction history review for the 241-AP tank farm. The construction history of the 241-AP tank farm has been reviewed to identify issues similar to those experienced during tank AY-102 construction. Those issues and others impacting integrity are discussed based on information found in available construction records, using tank AY-102 as the comparison benchmark. In the 241-AP tank farm, the sixth double-shell tank farm constructed, tank bottom flatness, refractory material quality, post-weld stress relieving, and primary tank bottom weld rejection were improved.

  5. Development tests of LOX/LH 2 tank for H-I launch vehicle

    NASA Astrophysics Data System (ADS)

    Takamatsu, H.; Imagawa, K.; Ichimaru, Y.

    H-I is a future launch vehicle of Japan with a capability of placing more than 550 kg payload into a geostationary orbit. The National Space Development Agency of Japan (NASDA) is now directing its efforts to the final development of H-I launch vehicle. H-I's high launch capability is attained by adopting a newly developed second stage with a LOX/LH 2 propulsion system. The second stage propulsion system consists of a tank and an engine. The tank is 2.5 m in diameter and 5.7 m in length and contains 8.7 tons of propellants. This tank is an integral tank with a common bulkhead which separates the tank into forward LH 2 tank and aft LOX tank. The tank is made of 2219 aluminum alloy and is insulated with sprayed polyurethane foam. The common bulkhead is made of FRP honeycomb core and aluminium alloy surface sheets. The most critical item in the development of the tank is the common bulkhead, therefore the cryogenic structural test was carried out to verify the structural integrity of the bulkhead. The structural integrity of the whole LOX/LH 2 tank was verified by the cryogenic structural test of a sub-scale tank and the room temperature structural test of a prototype tank.

  6. 46 CFR 169.234 - Integral fuel oil tank examinations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... operator of the vessel shall have the tanks cleaned out and gas freed as necessary to permit internal... an examination of the fuel tanks of each vessel during an internal structural examination at... and internally examined if the marine inspector is able to determine by external examination that the...

  7. [Unipedal stance time and fall risk in the elderly].

    PubMed

    Domínguez-Carrillo, Luis Gerardo; Arellano-Aguilar, Gregorio; Leos-Zierold, Héctor

    2007-01-01

    We undertook this study to relate unipodal stance time (UST) as a falls indicator in the elderly and to corroborate with UST exercise increments. One hundred sixty eight elderly subjects (age >70 years) with two or more falls during the previous 12 months were compared with 150 similar subjects without falls. UST chronometry and quadriceps and triceps brachialis strength dynamometry were used. Equilibrium and antigravity muscle-strengthening exercise program with 20 work sessions were carried out. Results were analyzed with chi(2), Student's t-test, and Fisher tests. UST of the control group showed 28.84 +/- 4.73 sec (mean +/- SD). The UST sample showed 19.18 +/- 4.24 sec. The test was initially impossible to carry out in 42 cases (p = 0.05). The final evaluation showed 142 cases with 30 sec of UST (p = 0.00001), isometric force increased in 70% and 30%, respectively (p = 0.05). At 6-month follow-up, 53 falls were reported, 29 were in patients who could not accomplish UST measurement on initial evaluation. UST <30 sec is an indicator of falls in elderly people, and exercise programs increase UST.

  8. The use of patient experience survey data by out-of-hours primary care services: a qualitative interview study.

    PubMed

    Barry, Heather E; Campbell, John L; Asprey, Anthea; Richards, Suzanne H

    2016-11-01

    English National Quality Requirements mandate out-of-hours primary care services to routinely audit patient experience, but do not state how it should be done. We explored how providers collect patient feedback data and use it to inform service provision. We also explored staff views on the utility of out-of-hours questions from the English General Practice Patient Survey (GPPS). A qualitative study was conducted with 31 staff (comprising service managers, general practitioners and administrators) from 11 out-of-hours primary care providers in England, UK. Staff responsible for patient experience audits within their service were sampled and data collected via face-to-face semistructured interviews. Although most providers regularly audited their patients' experiences by using patient surveys, many participants expressed a strong preference for additional qualitative feedback. Staff provided examples of small changes to service delivery resulting from patient feedback, but service-wide changes were not instigated. Perceptions that patients lacked sufficient understanding of the urgent care system in which out-of-hours primary care services operate were common and a barrier to using feedback to enable change. Participants recognised the value of using patient experience feedback to benchmark services, but perceived weaknesses in the out-of-hours items from the GPPS led them to question the validity of using these data for benchmarking in its current form. The lack of clarity around how out-of-hours providers should audit patient experience hinders the utility of the National Quality Requirements. Although surveys were common, patient feedback data had only a limited role in service change. Data derived from the GPPS may be used to benchmark service providers, but refinement of the out-of-hours items is needed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  9. 241-AW Tank Farm Construction Extent of Condition Review for Tank Integrity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnes, Travis J.; Gunter, Jason R.; Reeploeg, Gretchen E.

    2013-11-19

    This report provides the results of an extent of condition construction history review for the 241-AW tank farm. The construction history of the 241-AW tank farm has been reviewed to identify issues similar to those experienced during tank AY-102 construction. Those issues and others impacting integrity are discussed based on information found in available construction records, using tank AY-102 as the comparison benchmark. In the 241-AW tank farm, the fourth double-shell tank farm constructed, similar issues as those with tank 241-AY-102 construction occured. The overall extent of similary and affect on 241-AW tank farm integrity is described herein.

  10. 40 CFR 280.94 - Allowable mechanisms and combinations of mechanisms.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... requirements of the financial test under this rule, the financial statements of the owner or operator are not consolidated with the financial statements of the guarantor. [53 FR 43370, Oct. 26, 1988, as amended at 58 FR... OPERATORS OF UNDERGROUND STORAGE TANKS (UST) Financial Responsibility § 280.94 Allowable mechanisms and...

  11. Examination of sludge accumulation rates and sludge characteristics for a decentralized community wastewater treatment systems with individual primary clarifier tanks located in Wardsville (Ontario, Canada).

    PubMed

    Lossing, Heather; Champagne, Pascale; McLellan, P James

    2010-01-01

    In conventional septic systems, settling and partial treatment via anaerobic digestion occurs in the septic tank. One of the byproducts of solids separation in the septic tank is a semi-liquid material known as septage, which must be periodically pumped out. Septage includes the liquid portion within the tank, as well as the sludge that settles at the bottom of the tank and the scum that floats to the surface of the liquid layer. A number of factors can influence septage characteristics, as well as the sludge and scum accumulation rates within the tank. This paper presents the results of a 2007 field sampling study conducted in Wardsville (Ontario, Canada). The field study examined 29 individual residential two-chamber septic tanks in a community serviced by a decentralized wastewater treatment system in operation for approximately 7 years without septage removal. The field investigation provided a comprehensive data set that allowed for statistical analysis of the data to assess the more critical factors influencing solids accumulation rates within each of the clarifier chambers. With this data, a number of predictive models were developed using water usage data for each residence as an explanatory variable.

  12. Using Geographical Information Systems (GIS) to Identify the Geographic Regions Where People That Use Ground Water are Most Vulnerable to Impacts from Underground Storage

    EPA Science Inventory

    Using Geographic Information Systems (GIS), the vulnerability of ground water supplies to contamination from underground storage tanks (USTs) was assessed. The analysis was conducted for the 48 contiguous states, and then again for groups of states corresponding to the EPA Regio...

  13. 40 CFR 280.40 - General requirements for all UST systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... release detection that: (1) Can detect a release from any portion of the tank and the connected... shown in the table) with a probability of detection (Pd) of 0.95 and a probability of false alarm (Pfa) of 0.05. Method Section Date after which Pd/Pfa must be demonstrated Manual Tank Gauging 280.43(b...

  14. 40 CFR 280.40 - General requirements for all UST systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... release detection that: (1) Can detect a release from any portion of the tank and the connected... shown in the table) with a probability of detection (Pd) of 0.95 and a probability of false alarm (Pfa) of 0.05. Method Section Date after which Pd/Pfa must be demonstrated Manual Tank Gauging 280.43(b...

  15. 40 CFR 280.40 - General requirements for all UST systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... release detection that: (1) Can detect a release from any portion of the tank and the connected... shown in the table) with a probability of detection (Pd) of 0.95 and a probability of false alarm (Pfa) of 0.05. Method Section Date after which Pd/Pfa must be demonstrated Manual Tank Gauging 280.43(b...

  16. 40 CFR 280.40 - General requirements for all UST systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... release detection that: (1) Can detect a release from any portion of the tank and the connected... shown in the table) with a probability of detection (Pd) of 0.95 and a probability of false alarm (Pfa) of 0.05. Method Section Date after which Pd/Pfa must be demonstrated Manual Tank Gauging 280.43(b...

  17. 40 CFR 280.40 - General requirements for all UST systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... release detection that: (1) Can detect a release from any portion of the tank and the connected... shown in the table) with a probability of detection (Pd) of 0.95 and a probability of false alarm (Pfa) of 0.05. Method Section Date after which Pd/Pfa must be demonstrated Manual Tank Gauging 280.43(b...

  18. Optimization of armored spherical tanks for storage on the lunar surface

    NASA Technical Reports Server (NTRS)

    Bents, D. J.; Knight, D. A.

    1992-01-01

    A redundancy strategy for reducing micrometeroid armoring mass is investigated, with application to cryogenic reactant storage for a regenerative fuel cell (RFC) on the lunar surface. In that micrometeoroid environment, the cryogenic fuel must be protected from loss due to tank puncture. The tankage must have a sufficiently high probability of survival over the length of the mission so that the probability of system failure due to tank puncture is low compared to the other mission risk factors. Assuming that a single meteoroid penetration can cause a storage tank to lose its contents, two means are available to raise the probability of surviving micrometeoroid attack to the desired level. One can armor the tanks to a thickness sufficient to reduce probability of penetration of any tank to the desired level or add extra capacity in the form of space tanks that results in survival of a given number out of the ensemble at the desired level. A combination of these strategies (armor and redundancy) is investigated.

  19. 10. SETTLING TANK CLEANOUT DOORS, SOUTH SIDE; USED TO CLEAN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. SETTLING TANK CLEAN-OUT DOORS, SOUTH SIDE; USED TO CLEAN DEBRIS FROM SURFACE OF WATER IN SETTLING TANK. - Hondius Water Line, 1.6 miles Northwest of Park headquarters building & 1 mile Northwest of Beaver Meadows entrance station, Estes Park, Larimer County, CO

  20. 49 CFR 180.519 - Periodic retest and inspection of tank cars other than single-unit tank car tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Periodic retest and inspection of tank cars other than single-unit tank car tanks. 180.519 Section 180.519 Transportation Other Regulations Relating to... (CONTINUED) CONTINUING QUALIFICATION AND MAINTENANCE OF PACKAGINGS Qualification and Maintenance of Tank Cars...

  1. 49 CFR 180.519 - Periodic retest and inspection of tank cars other than single-unit tank car tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Periodic retest and inspection of tank cars other than single-unit tank car tanks. 180.519 Section 180.519 Transportation Other Regulations Relating to... (CONTINUED) CONTINUING QUALIFICATION AND MAINTENANCE OF PACKAGINGS Qualification and Maintenance of Tank Cars...

  2. 49 CFR 180.519 - Periodic retest and inspection of tank cars other than single-unit tank car tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Periodic retest and inspection of tank cars other than single-unit tank car tanks. 180.519 Section 180.519 Transportation Other Regulations Relating to... (CONTINUED) CONTINUING QUALIFICATION AND MAINTENANCE OF PACKAGINGS Qualification and Maintenance of Tank Cars...

  3. 49 CFR 180.519 - Periodic retest and inspection of tank cars other than single-unit tank car tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Periodic retest and inspection of tank cars other than single-unit tank car tanks. 180.519 Section 180.519 Transportation Other Regulations Relating to... (CONTINUED) CONTINUING QUALIFICATION AND MAINTENANCE OF PACKAGINGS Qualification and Maintenance of Tank Cars...

  4. 49 CFR 195.205 - Repair, alteration and reconstruction of aboveground breakout tanks that have been in service.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...-refrigerated and tanks built to API Standard 650 or its predecessor Standard 12C, repair, alteration, and reconstruction must be in accordance with API Standard 653. (2) For tanks built to API Specification 12F or API..., examination, and material requirements of those respective standards. (3) For high pressure tanks built to API...

  5. 49 CFR 195.205 - Repair, alteration and reconstruction of aboveground breakout tanks that have been in service.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...-refrigerated and tanks built to API Standard 650 or its predecessor Standard 12C, repair, alteration, and reconstruction must be in accordance with API Standard 653. (2) For tanks built to API Specification 12F or API..., examination, and material requirements of those respective standards. (3) For high pressure tanks built to API...

  6. 49 CFR 195.205 - Repair, alteration and reconstruction of aboveground breakout tanks that have been in service.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...-refrigerated and tanks built to API Standard 650 or its predecessor Standard 12C, repair, alteration, and reconstruction must be in accordance with API Standard 653. (2) For tanks built to API Specification 12F or API..., examination, and material requirements of those respective standards. (3) For high pressure tanks built to API...

  7. 49 CFR 195.205 - Repair, alteration and reconstruction of aboveground breakout tanks that have been in service.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...-refrigerated and tanks built to API Standard 650 or its predecessor Standard 12C, repair, alteration, and reconstruction must be in accordance with API Standard 653. (2) For tanks built to API Specification 12F or API..., examination, and material requirements of those respective standards. (3) For high pressure tanks built to API...

  8. 40 CFR 280.50 - Reporting of suspected releases.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., the sudden loss of product from the UST system, or an unexplained presence of water in the tank... vapors in soils, basements, sewer and utility lines, and nearby surface water). (b) Unusual operating...; or (2) In the case of inventory control, a second month of data does not confirm the initial result. ...

  9. 46 CFR 119.435 - Integral fuel tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... for certification of a vessel, integral fuel tanks must withstand a hydrostatic pressure test of 35 kPa (5 psig), or the maximum pressure head to which they may be subjected in service, whichever is...

  10. TankSIM: A Cryogenic Tank Performance Prediction Program

    NASA Technical Reports Server (NTRS)

    Bolshinskiy, L. G.; Hedayat, A.; Hastings, L. J.; Moder, J. P.; Schnell, A. R.; Sutherlin, S. G.

    2015-01-01

    Accurate prediction of the thermodynamic state of the cryogenic propellants in launch vehicle tanks is necessary for mission planning and successful execution. Cryogenic propellant storage and transfer in space environments requires that tank pressure be controlled. The pressure rise rate is determined by the complex interaction of external heat leak, fluid temperature stratification, and interfacial heat and mass transfer. If the required storage duration of a space mission is longer than the period in which the tank pressure reaches its allowable maximum, an appropriate pressure control method must be applied. Therefore, predictions of the pressurization rate and performance of pressure control techniques in cryogenic tanks are required for development of cryogenic fluid long-duration storage technology and planning of future space exploration missions. This paper describes an analytical tool, Tank System Integrated Model (TankSIM), which can be used for modeling pressure control and predicting the behavior of cryogenic propellant for long-term storage for future space missions. It is written in the FORTRAN 90 language and can be compiled with any Visual FORTRAN compiler. A thermodynamic vent system (TVS) is used to achieve tank pressure control. Utilizing TankSIM, the following processes can be modeled: tank self-pressurization, boiloff, ullage venting, and mixing. Details of the TankSIM program and comparisons of its predictions with test data for liquid hydrogen and liquid methane will be presented in the final paper.

  11. Out-of-pocket payments for health care services in Bulgaria: financial burden and barrier to access.

    PubMed

    Atanasova, Elka; Pavlova, Milena; Moutafova, Emanuela; Rechel, Bernd; Groot, Wim

    2013-12-01

    In recent years, Bulgaria has increasingly relied on out-of-pocket payments as one of the main sources of health care financing. However, it is largely unknown whether the official patient charges, combined with informal payments, are affordable for the population. Our study aimed to explore the scale of out-of-pocket payments for health care services and their affordability. Data were collected in two nationally representative surveys, conducted in Bulgaria in 2010 and 2011, using face-to-face interviews based on a standardized questionnaire. To select respondents, a multi-stage random probability method was used. The questionnaire included questions on the out-of-pocket payments for health care services used by the respondent during the preceding 12 months. In total, 75.7% (2010) and 84.0% (2011) of outpatient service users reported to have paid out-of-pocket, with 12.6% (2010) and 9.7% (2011) of users reporting informal payments. Of those who had used inpatient services, 66.5% (2010) and 63.1% (2011) reported to have made out-of-pocket payments, with 31.8% (2010) and 18.3% (2011) reporting to have paid informally. We found large inability to pay indicated by the need to borrow money and/or forego services. Regression analysis showed that the inability to pay is especially pronounced among those with poor health status and chronic diseases and those on low household incomes. The high level of both formal and informal out-of-pocket payments for health care services in Bulgaria poses a considerable burden for households and undermines access to health services for poorer parts of the population.

  12. 33 CFR 157.15 - Slop tanks in tank vessels.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Slop tanks in tank vessels. 157... (CONTINUED) POLLUTION RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Design, Equipment, and Installation § 157.15 Slop tanks in tank vessels. (a) Number. A...

  13. 33 CFR 157.15 - Slop tanks in tank vessels.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Slop tanks in tank vessels. 157... (CONTINUED) POLLUTION RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Design, Equipment, and Installation § 157.15 Slop tanks in tank vessels. (a) Number. A...

  14. 33 CFR 157.15 - Slop tanks in tank vessels.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Slop tanks in tank vessels. 157... (CONTINUED) POLLUTION RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Design, Equipment, and Installation § 157.15 Slop tanks in tank vessels. (a) Number. A...

  15. 33 CFR 157.15 - Slop tanks in tank vessels.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Slop tanks in tank vessels. 157... (CONTINUED) POLLUTION RULES FOR THE PROTECTION OF THE MARINE ENVIRONMENT RELATING TO TANK VESSELS CARRYING OIL IN BULK Design, Equipment, and Installation § 157.15 Slop tanks in tank vessels. (a) Number. A...

  16. CFD analysis of aircraft fuel tanks thermal behaviour

    NASA Astrophysics Data System (ADS)

    Zilio, C.; Longo, G. A.; Pernigotto, G.; Chiacchio, F.; Borrelli, P.; D'Errico, E.

    2017-11-01

    This work is carried out within the FP7 European research project TOICA (Thermal Overall Integrated Conception of Aircraft, http://www.toica-fp7.eu/). One of the tasks foreseen for the TOICA project is the analysis of fuel tanks as possible heat sinks for future aircrafts. In particular, in the present paper, commercial regional aircraft is considered as case study and CFD analysis with the commercial code STAR-CCM+ is performed in order to identify the potential capability to use fuel stored in the tanks as a heat sink for waste heat dissipated by other systems. The complex physical phenomena that characterize the heat transfer inside liquid fuel, at the fuel-ullage interface and inside the ullage are outlined. Boundary conditions, including the effect of different ground and flight conditions, are implemented in the numerical simulation approach. The analysis is implemented for a portion of aluminium wing fuel tank, including the leading edge effects. Effect of liquid fuel transfer among different tank compartments and the air flow in the ullage is included. According to Fuel Tank Flammability Assessment Method (FTFAM) proposed by the Federal Aviation Administration, the results are exploited in terms of exponential time constants and fuel temperature difference to the ambient for the different cases investigated.

  17. 27 CFR 24.229 - Tank car and tank truck requirements.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Tank car and tank truck... BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL WINE Spirits § 24.229 Tank car and tank truck requirements. Railroad tank cars and tank trucks used to transport spirits for use in wine production will be constructed...

  18. 27 CFR 24.229 - Tank car and tank truck requirements.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Tank car and tank truck... BUREAU, DEPARTMENT OF THE TREASURY LIQUORS WINE Spirits § 24.229 Tank car and tank truck requirements. Railroad tank cars and tank trucks used to transport spirits for use in wine production will be constructed...

  19. 27 CFR 24.229 - Tank car and tank truck requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Tank car and tank truck... BUREAU, DEPARTMENT OF THE TREASURY LIQUORS WINE Spirits § 24.229 Tank car and tank truck requirements. Railroad tank cars and tank trucks used to transport spirits for use in wine production will be constructed...

  20. 27 CFR 24.229 - Tank car and tank truck requirements.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Tank car and tank truck... BUREAU, DEPARTMENT OF THE TREASURY ALCOHOL WINE Spirits § 24.229 Tank car and tank truck requirements. Railroad tank cars and tank trucks used to transport spirits for use in wine production will be constructed...

  1. 27 CFR 24.229 - Tank car and tank truck requirements.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Tank car and tank truck... BUREAU, DEPARTMENT OF THE TREASURY LIQUORS WINE Spirits § 24.229 Tank car and tank truck requirements. Railroad tank cars and tank trucks used to transport spirits for use in wine production will be constructed...

  2. Community Mental Health Services: Dropping-In and Dropping-Out.

    ERIC Educational Resources Information Center

    Lonigan, Christopher J.; Muzekari, Louis H.

    A number of studies have examined variables that discriminate individuals who drop out of mental health programs. However, relatively little attention has been focused on determining characteristics of individuals who fail to follow through after their initial contact with mental health services. This study was designed to provide a profile of…

  3. 1988 Underground Storage Tanks; Technical Requirements; Final Rule and Underground Storage Tanks Containing Petroleum-Financial Responsibility Requirements and State Program Approval Objective; Final Rule

    EPA Pesticide Factsheets

    EPA's 1988 regulations concerning USTs are contained in 40 CFR Part 280, 40 CFR Part 281 and 40 CFR Parts 282.50-282.105 and divided into three sections: technical requirements, financial responsibility requirements, and state program approval objectives.

  4. 241-AZ Tank Farm Construction Extent of Condition Review for Tank Integrity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnes, Travis J.; Boomer, Kayle D.; Gunter, Jason R.

    2013-07-30

    This report provides the results of an extent of condition construction history review for tanks 241-AZ-101 and 241-AZ-102. The construction history of the 241-AZ tank farm has been reviewed to identify issues similar to those experienced during tank AY-102 construction. Those issues and others impacting integrity are discussed based on information found in available construction records, using tank AY-102 as the comparison benchmark. In the 241-AZ tank farm, the second DST farm constructed, both refractory quality and tank and liner fabrication were improved.

  5. Health out of foster care as young adults age out of foster care: A phenomenological exploration of seeking healthcare services after aging out of the US foster care system.

    PubMed

    Collins, Jennifer L; Jimenez, Rosalinda; Thomas, Laura J

    2018-05-17

    Some adolescents in the United States who have been abused and/or neglected by caregivers and placed in permanent custody of the state leave, or "age out" of foster care at 18 years of age. Poor health outcomes among individuals who age out are notable, yet few studies describe the phenomenon of seeking healthcare services after leaving foster care. The investigators specifically queried the phenomenon of seeking healthcare services after foster care drawing from the Phenomenology of Practice approach. We interviewed 13 young adults who aged out of care. Investigators extracted lived experience descriptions (LEDs) from interview transcripts and analyzed under phenomenological themes. Healthcare experiences were marked by avoiding self-disclosure, having no choice but to wait, missing family history, and relying on the kindness of strangers. Healthcare providers who integrate the findings into care delivery models will engage young adults with more understanding and sensitivities of ethical practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Can contracted out health facilities improve access, equity, and quality of maternal and newborn health services? Evidence from Pakistan.

    PubMed

    Zaidi, Shehla; Riaz, Atif; Rabbani, Fauziah; Azam, Syed Iqbal; Imran, Syeda Nida; Pradhan, Nouhseen Akber; Khan, Gul Nawaz

    2015-11-25

    The case of contracting out government health services to non-governmental organizations (NGOs) has been weak for maternal, newborn, and child health (MNCH) services, with documented gains being mainly in curative services. We present an in-depth assessment of the comparative advantages of contracting out on MNCH access, quality, and equity, using a case study from Pakistan. An end-line, cross-sectional assessment was conducted of government facilities contracted out to a large national NGO and government-managed centres serving as controls, in two remote rural districts of Pakistan. Contracting out was specific for augmenting MNCH services but without contractual performance incentives. A household survey, a health facility survey, and focus group discussions with client and spouses were used for assessment. Contracted out facilities had a significantly higher utilization as compared to control facilities for antenatal care, delivery, postnatal care, emergency obstetric care, and neonatal illness. Contracted facilities had comparatively better quality of MNCH services but not in all aspects. Better household practices were also seen in the district where contracting involved administrative control over outreach programs. Contracting was also faced with certain drawbacks. Facility utilization was inequitably higher amongst more educated and affluent clients. Contracted out catchments had higher out-of-pocket expenses on MNCH services, driven by steeper transport costs and user charges for additional diagnostics. Contracting out did not influence higher MNCH service coverage rates across the catchment. Physical distances, inadequate transport, and low demand for facility-based care in non-emergency settings were key client-reported barriers. Contracting out MNCH services at government health facilities can improve facility utilization and bring some improvement in  quality of services. However, contracting out of health facilities is insufficient to increase

  7. CLOSURE REPORT FOR CORRECTIVE ACTION UNIT 204: STORAGE BUNKERS, NEVADA TEST SITE, NEVADA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Corrective Action Unit (CAU) 330 consists of four Corrective Action Sites (CASs) located in Areas 6, 22, and 23 of the Nevada Test Site (NTS). The unit is listed in the Federal Facility Agreement and Consent Order (FFACO, 1996) as CAU 330: Areas 6, 22, and 23 Tanks and Spill Sites. CAU 330 consists of the following CASs: CAS 06-02-04, Underground Storage Tank (UST) and Piping CAS 22-99-06, Fuel Spill CAS 23-01-02, Large Aboveground Storage Tank (AST) Farm CAS 23-25-05, Asphalt Oil Spill/Tar Release

  8. Investigation of Corrosion-Influencing Factors in Underground Storage Tanks with Diesel Service

    EPA Science Inventory

    This paper summarized the research findings of an effort undertaken by EPA to understand possible causes and solutions to widespread reports of severe corrosion of metal components in underground storage tank systems storing diesel fuel since 2007.

  9. Preliminary Thermal Stress Analysis of a High-Pressure Cryogenic Storage Tank

    NASA Technical Reports Server (NTRS)

    Baker, J. Mark

    2003-01-01

    The thermal stresses on a cryogenic storage tank strongly affect the condition of the tank and its ability to withstand operational stresses. These thermal stresses also affect the growth of any surface damage that might occur in the tank walls. These stresses are particularly of concern during the initial cooldown period for a new tank placed into service, and during any subsequent thermal cycles. A preliminary thermal stress analysis of a high-pressure cryogenic storage tank was performed. Stresses during normal operation were determined, as well as the transient temperature distribution. An elastic analysis was used to determine the thermal stresses in the inner wall based on the temperature data. The results of this elastic analysis indicate that the inner wall of the storage tank will experience thermal stresses of approximately 145,000 psi (1000 MPa). This stress level is well above the room-temperature yield strength of 304L stainless steel, which is about 25,000 psi (170 MPa). For this preliminary analysis, several important factors have not yet been considered. These factors include increased strength of 304L stainless steel at cryogenic temperatures, plastic material behavior, and increased strength due to strain hardening. In order to more accurately determine the thermal stresses and their affect on the tank material, further investigation is required, particularly in the area of material properties and their relationship to stress.

  10. 76 FR 39095 - Compatibility of Underground Storage Tank Systems With Biofuel Blends

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-05

    ... drinking water for nearly half of all Americans, the U.S. Environmental Protection Agency (EPA) regulates... components of the UST system, such as leak detection devices, sealants, and containment sumps, may not be... demonstration of compatibility. Some commenters suggested that EPA allow the National Work Group on Leak...

  11. 12 CFR 716.13 - Exception to opt out requirements for service providers and joint marketing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 12 Banks and Banking 6 2011-01-01 2011-01-01 false Exception to opt out requirements for service providers and joint marketing. 716.13 Section 716.13 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION... opt out requirements for service providers and joint marketing. (a) General rule. (1) The opt out...

  12. Hanford Double-Shell Tank AY-102 Radioactive Waste Leak Investigation Update - 15302

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Washenfelder, D. J.; Johnson, J. M.

    2014-12-22

    Tank AY-102 was the first of 28 double-shell radioactive waste storage tanks constructed at the U. S. Department of Energy’s Hanford Site, near Richland, WA. The tank was completed in 1970, and entered service in 1971. In August, 2012, an accumulation of material was discovered at two sites on the floor of the annulus that separates the primary tank from the secondary liner. The material was sampled and determined to originate from the primary tank. This paper summarizes the changes in leak behavior that have occurred during the past two years, inspections to determine the capability of the secondary linermore » to continue safely containing the leakage, and the initial results of testing to determine the leak mechanism.« less

  13. Computational Analyses of Pressurization in Cryogenic Tanks

    NASA Technical Reports Server (NTRS)

    Ahuja, Vineet; Hosangadi, Ashvin; Lee, Chun P.; Field, Robert E.; Ryan, Harry

    2010-01-01

    A comprehensive numerical framework utilizing multi-element unstructured CFD and rigorous real fluid property routines has been developed to carry out analyses of propellant tank and delivery systems at NASA SSC. Traditionally CFD modeling of pressurization and mixing in cryogenic tanks has been difficult primarily because the fluids in the tank co-exist in different sub-critical and supercritical states with largely varying properties that have to be accurately accounted for in order to predict the correct mixing and phase change between the ullage and the propellant. For example, during tank pressurization under some circumstances, rapid mixing of relatively warm pressurant gas with cryogenic propellant can lead to rapid densification of the gas and loss of pressure in the tank. This phenomenon can cause serious problems during testing because of the resulting decrease in propellant flow rate. With proper physical models implemented, CFD can model the coupling between the propellant and pressurant including heat transfer and phase change effects and accurately capture the complex physics in the evolving flowfields. This holds the promise of allowing the specification of operational conditions and procedures that could minimize the undesirable mixing and heat transfer inherent in propellant tank operation. In our modeling framework, we incorporated two different approaches to real fluids modeling: (a) the first approach is based on the HBMS model developed by Hirschfelder, Beuler, McGee and Sutton and (b) the second approach is based on a cubic equation of state developed by Soave, Redlich and Kwong (SRK). Both approaches cover fluid properties and property variation spanning sub-critical gas and liquid states as well as the supercritical states. Both models were rigorously tested and properties for common fluids such as oxygen, nitrogen, hydrogen etc were compared against NIST data in both the sub-critical as well as supercritical regimes.

  14. Corrosion Evaluation of Tank 40 Leak Detection Box

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mickalonis, J.I.

    1999-07-29

    'Leak detection from the transfer lines in the tank farm has been a concern for many years because of the need to minimize exposure of personnel and contamination of the environment. The leak detection box (LDB) is one line of defense, which must be maintained to meet this objective. The evaluation of a failed LDB was one item from an action plan aimed at minimizing the degradation of LDBs. The Tank 40 LDB, which failed in service, was dug up and shipped to SRTC for evaluation. During a video inspection while in service, this LDB was found to have blackmore » tubercles on the interior, which suggested possible microbial involvement. The failure point, however, was believed to have occurred in the drain line from the transfer line jacket. Visual, metallurgical, and biological analyses were performed on the LDB. The analysis results showed that there was not any adverse microbiological growth or significant localized corrosion. The corrosion of the LDB was caused by exposure to aqueous environments and was typical of carbon steel pipes in soil environments.'« less

  15. 33 CFR 157.15 - Slop tanks in tank vessels.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... tank. (2) A new vessel of 70,000 tons DWT or more must have at least two slop tanks. (b) Capacity. Slop tanks must have the total capacity to retain oily mixtures from cargo tank washings, oil residue, and ballast water containing an oily mixture of 3 percent or more of the oil carrying capacity. Two percent...

  16. Dual Tank Fuel System

    DOEpatents

    Wagner, Richard William; Burkhard, James Frank; Dauer, Kenneth John

    1999-11-16

    A dual tank fuel system has primary and secondary fuel tanks, with the primary tank including a filler pipe to receive fuel and a discharge line to deliver fuel to an engine, and with a balance pipe interconnecting the primary tank and the secondary tank. The balance pipe opens close to the bottom of each tank to direct fuel from the primary tank to the secondary tank as the primary tank is filled, and to direct fuel from the secondary tank to the primary tank as fuel is discharged from the primary tank through the discharge line. A vent line has branches connected to each tank to direct fuel vapor from the tanks as the tanks are filled, and to admit air to the tanks as fuel is delivered to the engine.

  17. Farming in a fish tank.

    PubMed

    Youth, H

    1992-01-01

    Water, fish, and vegetables are all things that most developing countries do not have enough of. There is a method of food production called aquaculture that integrates fish and vegetable growing and conserves and purifies water at the same time. A working system that grows vegetables and fish for regional supermarkets in Massachusetts is a gravity fed system. At the top of the system is a 3,000 gallon fish rearing tank that measures 12 feet in diameter. Water trickles out of the tank and fish wastes are captured which can be composted and used in farm fields. The water goes into a bio filter that contains bacteria which convert harmful ammonia generated from fish waste into beneficial nitrate. Then the water flows into 100 foot long hydroponic tanks where lettuce grows. A 1/6 horsepower pump return the purified water to the fish tank and completes the cycle. The key to success is maintaining a balance between the fish nutrients and waste and the plants nutrients and waste. The system is estimated to produce 35,000 heads of lettuce and 2 tons of fish annually which translates into $23,500. The system could be adapted to developing countries with several modifications to reduce the start up cost.

  18. Tank System Integrated Model: A Cryogenic Tank Performance Prediction Program

    NASA Technical Reports Server (NTRS)

    Bolshinskiy, L. G.; Hedayat, A.; Hastings, L. J.; Sutherlin, S. G.; Schnell, A. R.; Moder, J. P.

    2017-01-01

    Accurate predictions of the thermodynamic state of the cryogenic propellants, pressurization rate, and performance of pressure control techniques in cryogenic tanks are required for development of cryogenic fluid long-duration storage technology and planning for future space exploration missions. This Technical Memorandum (TM) presents the analytical tool, Tank System Integrated Model (TankSIM), which can be used for modeling pressure control and predicting the behavior of cryogenic propellant for long-term storage for future space missions. Utilizing TankSIM, the following processes can be modeled: tank self-pressurization, boiloff, ullage venting, mixing, and condensation on the tank wall. This TM also includes comparisons of TankSIM program predictions with the test data andexamples of multiphase mission calculations.

  19. Prototype volumetric ultrasound tomography image guidance system for prone stereotactic partial breast irradiation: proof-of-concept

    NASA Astrophysics Data System (ADS)

    Chiu, Tsuicheng D.; Parsons, David; Zhang, Yue; Hrycushko, Brian; Zhao, Bo; Chopra, Rajiv; Kim, Nathan; Spangler, Ann; Rahimi, Asal; Timmerman, Robert; Jiang, Steve B.; Lu, Weiguo; Gu, Xuejun

    2018-03-01

    Accurate dose delivery in stereotactic partial breast irradiation (S-PBI) is challenging because of the target position uncertainty caused by breast deformation, the target volume changes caused by lumpectomy cavity shrinkage, and the target delineation uncertainty on simulation computed tomography (CT) images caused by poor soft tissue contrast. We have developed a volumetric ultrasound tomography (UST) image guidance system for prone position S-PBI. The system is composed of a novel 3D printed rotation water tank, a patient-specific resin breast immobilization cup, and a 1D array ultrasound transducer. Coronal 2D US images were acquired in 5° increments over a 360° range, and planes were acquired every 2 mm in elevation. A super-compounding technique was used to reconstruct the image volume. The image quality of UST was evaluated with a BB-1 breast phantom and BioZorb surgical marker, and the results revealed that UST offered better soft tissue contrast than CT and similar image quality to MR. In the evaluated plane, the size and location of five embedded objects were measured and compared to MR, which is considered as the ground truth. Objects’ diameters and the distances between objects in UST differ by approximately 1 to 2 mm from those in MR, which showed that UST offers the image quality required for S-PBI. In future work we will develop a robotic system that will be ultimately implemented in the clinic.

  20. Prototype volumetric ultrasound tomography image guidance system for prone stereotactic partial breast irradiation: proof-of-concept.

    PubMed

    Chiu, Tsuicheng D; Parsons, David; Zhang, Yue; Hrycushko, Brian; Zhao, Bo; Chopra, Rajiv; Kim, Nathan; Spangler, Ann; Rahimi, Asal; Timmerman, Robert; Jiang, Steve B; Lu, Weiguo; Gu, Xuejun

    2018-03-01

    Accurate dose delivery in stereotactic partial breast irradiation (S-PBI) is challenging because of the target position uncertainty caused by breast deformation, the target volume changes caused by lumpectomy cavity shrinkage, and the target delineation uncertainty on simulation computed tomography (CT) images caused by poor soft tissue contrast. We have developed a volumetric ultrasound tomography (UST) image guidance system for prone position S-PBI. The system is composed of a novel 3D printed rotation water tank, a patient-specific resin breast immobilization cup, and a 1D array ultrasound transducer. Coronal 2D US images were acquired in 5° increments over a 360° range, and planes were acquired every 2 mm in elevation. A super-compounding technique was used to reconstruct the image volume. The image quality of UST was evaluated with a BB-1 breast phantom and BioZorb surgical marker, and the results revealed that UST offered better soft tissue contrast than CT and similar image quality to MR. In the evaluated plane, the size and location of five embedded objects were measured and compared to MR, which is considered as the ground truth. Objects' diameters and the distances between objects in UST differ by approximately 1 to 2 mm from those in MR, which showed that UST offers the image quality required for S-PBI. In future work we will develop a robotic system that will be ultimately implemented in the clinic.

  1. Compatibility of the Radio Frequency Mass Gauge with Composite Tanks

    NASA Technical Reports Server (NTRS)

    Zimmerli, Greg; Mueller, Carl

    2015-01-01

    The radio frequency mass gauge (RFMG) is a low-gravity propellant quantity gauge being developed at NASA for possible use in long-duration space missions utilizing cryogenic propellants. As part of the RFMG technology development process, we evaluated the compatibility of the RFMG with a graphite-epoxy composite material used to construct propellant tanks. The key material property that can affect compatibility with the RFMG is the electrical conductivity. Using samples of 8552IM7 graphite-epoxy composite, we characterized the resistivity and reflectivity over a range of frequencies. An RF impedance analyzer was used to characterize the out-of-plane electrical properties (along the sample thickness) in the frequency range 10 to 1800 MHZ. The resistivity value at 500 MHz was 4.8 ohm-cm. Microwave waveguide measurements of samples in the range 1.7 2.6 GHz, performed by inserting the samples into a WR-430 waveguide, showed reflectivity values above 98. Together, these results suggested that a tank constructed from graphite-epoxy composite would produce good quality electromagnetic tank modes, which is needed for the RFMG. This was verified by room-temperature measurements of the electromagnetic modes of a 2.4 m diameter tank constructed by Boeing from similar graphite-epoxy composite material. The quality factor Q of the tank electromagnetic modes, measured via RF reflection measurements from an antenna mounted in the tank, was typically in the range 400 Q 3000. The good quality modes observed in the tank indicate that the RFMG is compatible with graphite-epoxy tanks, and thus the RFMG could be used as a low-gravity propellant quantity gauge in such tanks filled with cryogenic propellants.

  2. ACOUSTIC LOCATION OF LEAKS IN PRESSURIZED UNDER- GROUND PETROLEUM PIPELINES

    EPA Science Inventory

    Experiments were conducted at the Underground Storage Tank (UST) Test Apparatus Pipeline in which three acoustic sensors separated by a maximum distance of 38.1 m (125 ft) were used to monitor signals produced by 11.4-, 5.7-, and 3.8-L/h (3.0-, 1.5-, and 1.0-gal/h) leaks in th...

  3. Interior of Vacuum Tank at the Electric Propulsion Laboratory

    NASA Image and Video Library

    1961-08-21

    Interior of the 20-foot diameter vacuum tank at the NASA Lewis Research Center’s Electric Propulsion Laboratory. Lewis researchers had been studying different electric rocket propulsion methods since the mid-1950s. Harold Kaufman created the first successful ion engine, the electron bombardment ion engine, in the early 1960s. These engines used electric power to create and accelerate small particles of propellant material to high exhaust velocities. Electric engines have a very small thrust, but can operate for long periods of time. The ion engines are often clustered together to provide higher levels of thrust. The Electric Propulsion Laboratory, which began operation in 1961, contained two large vacuum tanks capable of simulating a space environment. The tanks were designed especially for testing ion and plasma thrusters and spacecraft. The larger 25-foot diameter tank included a 10-foot diameter test compartment to test electric thrusters with condensable propellants. The portals along the chamber floor lead to the massive exhauster equipment that pumped out the air to simulate the low pressures found in space.

  4. Environmental Education Activities & Programs 1998-1999.

    ERIC Educational Resources Information Center

    Bureau of Reclamation (Dept. of Interior), Denver, CO.

    This document features descriptions of interactive learning models and presentations in environmental education concerning groundwater, geology, the environment, weather, water activities, and interactive games. Activities include: (1) GW-Standard; (2) GW-w/no Leaky Underground Storage Tank (No UST); (3) GW-Karst; (4) GW-Landfill Models--Standard…

  5. Mental health beliefs and barriers to accessing mental health services in youth aging out of foster care.

    PubMed

    Sakai, Christina; Mackie, Thomas I; Shetgiri, Rashmi; Franzen, Sara; Partap, Anu; Flores, Glenn; Leslie, Laurel K

    2014-01-01

    To examine the perspectives of youth on factors that influence mental health service use after aging out of foster care. Focus groups were conducted with youth with a history of mental health needs and previous service use who had aged out of foster care. Questions were informed by the Health Belief Model and addressed 4 domains: youth perceptions of the "threat of mental health problems," treatment benefits versus barriers to accessing mental health services, self-efficacy, and "cues to action." Data were analyzed using a modified grounded-theory approach. Youth (N = 28) reported ongoing mental health problems affecting their functioning; however, they articulated variable levels of reliance on formal mental health treatment versus their own ability to resolve these problems without treatment. Past mental health service experiences influenced whether youth viewed treatment options as beneficial. Youth identified limited self-efficacy and insufficient psychosocial supports "cueing action" during their transition out of foster care. Barriers to accessing mental health services included difficulties obtaining health insurance, finding a mental health provider, scheduling appointments, and transportation. Youths' perceptions of their mental health needs, self-efficacy, psychosocial supports during transition, and access barriers influence mental health service use after aging out of foster care. Results suggest that strategies are needed to 1) help youth and clinicians negotiate shared understanding of mental health treatment needs and options, 2) incorporate mental health into transition planning, and 3) address insurance and other systemic barriers to accessing mental health services after aging out of foster care. Copyright © 2014 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  6. OVERVIEW OF CYANIDE PLANT FOUNDATIONS, ZINC BOXES, TANKS, AND TAILINGS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    OVERVIEW OF CYANIDE PLANT FOUNDATIONS, ZINC BOXES, TANKS, AND TAILINGS PILES, LOOKING NORTHEAST. THE LOWER TRAM TERMINAL AND MILL SITE IS AT TOP CENTER IN THE DISTANCE. THE DARK SPOT JUST BELOW THE TRAM TERMINAL ARE REMAINS OF THE DEWATERING BUILDING. THE MAIN ACCESS ROAD IS AT UPPER LEFT. THE FOUNDATIONS AT CENTER SUPPORTED SIX 25 FT. OR GREATER DIAMETER SETTLING TANKS WHERE TAILINGS FROM THE MILL SETTLED IN A CYANIDE SOLUTION IN ORDER TO RECLAIM ANY GOLD CONTENT. THE PREGNANT SOLUTION WAS THEN RUN THROUGH THE ZINC BOXES ON THE GROUND AT CENTER RIGHT, WHERE ZINC SHAVINGS WERE INTRODUCED, CAUSING THE GOLD TO PRECIPITATE OUT OF THE CYANIDE SOLUTION, WHICH COULD BE USED AGAIN. THE FLAT AREA IN THE FOREGROUND WITH THE TANK AND TANK HOOPS IS THE FOOTPRINT OF A LARGE BUILDING WHERE THE PRECIPITATION AND FURTHER FILTERING AND FINAL CASTING TOOK PLACE. - Keane Wonder Mine, Park Route 4 (Daylight Pass Cutoff), Death Valley Junction, Inyo County, CA

  7. Runtime and Pressurization Analyses of Propellant Tanks

    NASA Technical Reports Server (NTRS)

    Field, Robert E.; Ryan, Harry M.; Ahuja, Vineet; Hosangadi, Ashvin; Lee, Chung P.

    2007-01-01

    Multi-element unstructured CFD has been utilized at NASA SSC to carry out analyses of propellant tank systems in different modes of operation. The three regimes of interest at SSC include (a) tank chill down (b) tank pressurization and (c) runtime propellant draw-down and purge. While tank chill down is an important event that is best addressed with long time-scale heat transfer calculations, CFD can play a critical role in the tank pressurization and runtime modes of operation. In these situations, problems with contamination of the propellant by inclusion of the pressurant gas from the ullage causes a deterioration of the quality of the propellant delivered to the test article. CFD can be used to help quantify the mixing and propellant degradation. During tank pressurization under some circumstances, rapid mixing of relatively warm pressurant gas with cryogenic propellant can lead to rapid densification of the gas and loss of pressure in the tank. This phenomenon can cause serious problems during testing because of the resulting decrease in propellant flow rate. With proper physical models implemented, CFD can model the coupling between the propellant and pressurant including heat transfer and phase change effects and accurately capture the complex physics in the evolving flowfields. This holds the promise of allowing the specification of operational conditions and procedures that could minimize the undesirable mixing and heat transfer inherent in propellant tank operation. It should be noted that traditional CFD modeling is inadequate for such simulations because the fluids in the tank are in a range of different sub-critical and supercritical states and elaborate phase change and mixing rules have to be developed to accurately model the interaction between the ullage gas and the propellant. We show a typical run-time simulation of a spherical propellant tank, containing RP-1 in this case, being pressurized with room-temperature nitrogen at 540 R. Nitrogen

  8. 49 CFR 195.307 - Pressure testing aboveground breakout tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... placed in service after October 2, 2000, pneumatic testing must be in accordance with section 5.3 of API Specification 12 F (incorporated by reference, see § 195.3). (b) For aboveground breakout tanks built to API Standard 620 and first placed in service after October 2, 2000, hydrostatic and pneumatic testing must be...

  9. In-Tank Elutriation Test Report And Independent Assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burns, H. H.; Adamson, D. J.; Qureshi, Z. H.

    2011-04-13

    grown in size over a period of decades. 2. The radionuclides were apparently either in the form of soluble compounds, like cesium, or micrometer sized particles of actinide oxides or hydroxides. 3. After the initial tank retrieval the tank contained cobble which is not conducive to elutriation. Only after the tank contents were treated with thousands of gallons of 50 wt% caustic, were the solids converted to sand which is compatible with elutriation. Discussions between SRNL and PNNL resulted in plans to test elutriation in two phases; in Phase 1 particles would be separated by differences in settling velocity in an existing scaled tank with its associated hardware and in Phase 2 additional hardware, such as a hydrocyclone, would be added downstream to separate slow settling partciels from liquid. Phase 1 of in-tank elutriation was tested for Proof of Principle in theEngineering Development Laboratory of SRNL in a 41" diameter, 87 gallon tank. The tank had been previously used as a 1/22 scale model of Hanford Waste Tank AY-102. The objective of the testing was to determine which tank operating parameters achieved the best separation between fast- and slow-settling particles. For Phase 1 testing a simulated waste tank supernatant, slow-settling particles and fast-settling particles were loaded to the scaled tank. Because this was a Proof of Principle test, readily available solids particles were used that represented fast-settling and slow-settling particles. The tank contents were agitated using rotating mixer jet pumps (MJP) which suspended solids while liquids and solids were drawn out of the tank with a suction tube. The goal was to determine the optimum hydraulic operating conditions to achieve clean separation in which the residual solids in the tank were nearly all fast-settling particles and the solids transferred out of the tank were nearly all slow-settling particles. Tests were conducted at different pump jet velocities, suction tube diameters and suction tube

  10. A storage gas tank is moved to a pallet in the O&C

    NASA Technical Reports Server (NTRS)

    2001-01-01

    KENNEDY SPACE CENTER, Fla. -- Workers in the Operations and Checkout Building stand by while one of four gas tanks is moved toward the Spacelab Logistics Double Pallet. Part of the STS-104 payload, the storage tanks two gaseous oxygen and two gaseous nitrogen -- comprise the high pressure gas assembly that will be attached to the Joint Airlock Module during two spacewalks. The tanks will support future spacewalk operations from the Station and augment the Service Module gas resupply system.

  11. 40 CFR 280.91 - Compliance dates.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Compliance dates. 280.91 Section 280... (UST) Financial Responsibility § 280.91 Compliance dates. Owners of petroleum underground storage tanks are required to comply with the requirements of this subpart by the following dates: (a) All petroleum...

  12. MODELS AND METHODS FOR PETROLEUM HYDROCARBON RISK ASSESSMENT: ONSITE, LUSTRISK, AND HSSM

    EPA Science Inventory

    U.S. EPA has developed three tiers of models for analysis of fuel releases from underground storage tank (UST) systems: 1) OnSite; 2) LUSTRisk, and 3) the Hydrocarbon Spill Screening Model (HSSM). The tiered approach to modeling allows users to select a model based upon the amoun...

  13. Institutional Controls: A Guide to Planning, Implementing, Maintaining, and Enforcing Institutional Controls at Contaminated Sites

    EPA Pesticide Factsheets

    This guide provides information and recommendations that should be useful for planning, implementing, maintaining, and enforcing institutional controls (ICs) for Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA, or Superfund); Brownfields; federal facility; underground storage tank (UST); and Resource Conservation and Recovery Act (RCRA) site cleanups.

  14. 33 CFR 157.147 - Similar tank design: Inspections on foreign tank vessels.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Similar tank design: Inspections... § 157.147 Similar tank design: Inspections on foreign tank vessels. (a) If a foreign tank vessel has..., for only one of those tanks to be inspected under § 157.140(a)(1). (b) Only one tank of a group of...

  15. Pump tank divider plate for sump suction sodium pumps

    DOEpatents

    George, John A.; Nixon, Donald R.

    1977-01-01

    A circular plate extends across the diameter of "sump suction" pump, with a close clearance between the edge of the plate and the wall of the pump tank. The plate is located above the pump impeller, inlet and outlet flow nozzles but below the sodium free surface and effectively divides the pump tank into two separate chambers. On change of pump speed, the close fitting flow restriction plate limits the rate of flow into or out of the upper chamber, thereby minimizing the rate of level change in the tank and permitting time for the pump cover gas pressure to be varied to maintain an essentially constant level.

  16. Dementia and Out-of-Pocket Spending on Health Care Services

    PubMed Central

    Delavande, Adeline; Hurd, Michael D.; Martorell, Francisco; Langa, Kenneth M.

    2014-01-01

    Background High levels of out-of-pocket (OOP) spending for health care may lead patients to forego needed services and medications, as well as hamper their ability to pay for other essential goods. Dementia, because it leads to disability and the loss of independence may put patients and their families at risk for high OOP spending, especially for long-term care services. Methods We used data from the Aging, Demographics, and Memory Study, a nationally representative sub-sample (n=743) of the Health and Retirement Study, to determine whether individuals with dementia had higher self-reported OOP spending compared to those with cognitive impairment without dementia (CIND) and those with normal cognitive function. We also examined the relationship between dementia and utilization of dental care and prescription medications, two types of health care that are frequently paid for out-of-pocket. Multivariate and logistic regression models were used to adjust for the influence of potential confounders. Results After controlling for demographics and comorbidities, those with dementia had more than three times the yearly OOP spending compared to those with normal cognition ($8,216 for those with dementia vs. $2,570 for those with normal cognition, p<.01) Higher OOP spending for those with dementia was mainly driven by greater expenditures on nursing home care (p<.01). Dementia was not associated with the likelihood of visiting the dentist (p=0.76) or foregoing prescription medications due to cost (p=.34). Conclusions Dementia is associated with high levels of OOP spending, but not with the use of dental care or foregoing prescription medications, suggesting that excess OOP spending among those with dementia does not “crowd out” spending on these other health care services. PMID:23154049

  17. TANK 26 EVAPORATOR FEED PUMP TRANSFER ANALYSIS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tamburello, D; Si Lee, S; Richard Dimenna, R

    2008-09-30

    The transfer of liquid salt solution from Tank 26 to an evaporator is to be accomplished by activating the evaporator feed pump, located approximately 72 inches above the sludge layer, while simultaneously turning on the downcomer. Previously, activation of the evaporator feed pump was an isolated event without any other components running at the same time. An analysis of the dissolved solution transfer has been performed using computational fluid dynamics methods to determine the amount of entrained sludge solids pumped out of the tank to the evaporator with the downcomer turned on. The analysis results showed that, for the maximummore » and minimum supernate levels in Tank 26 (252.5 and 72 inches above the sludge layer, respectively), the evaporator feed pump will entrain between 0.05 and 0.1 wt% sludge solids weight fraction into the eductor, respectively. Lower tank liquid levels, with respect to the sludge layer, result in higher amounts of sludge entrainment due to the increased velocity of the plunging jets from the downcomer and evaporator feed pump bypass as well as decreased dissipation depth.« less

  18. The Fly-in Fly-out and Drive-in Drive-out model of health care service provision for rural and remote Australia: benefits and disadvantages.

    PubMed

    Hussain, Rafat; Maple, Myfanwy; Hunter, Sally V; Mapedzahama, Virginia; Reddy, Prasuna

    2015-01-01

    Rural Australians experience poorer health and poorer access to health care services than their urban counterparts, and there is a chronic shortage of health professionals in rural and remote Australia. Strategies designed to reduce this rural-urban divide include fly-in fly-out (FIFO) and drive-in drive-out (DIDO) services. The aim of this article is to examine the opportunities and challenges involved in these forms of service delivery. This article reviews recent literature relating to FIFO and DIDO healthcare services and discusses their benefits and potential disadvantages for rural Australia, and for health practitioners. FIFO and DIDO have short-term benefits for rural Australians seeking healthcare services in terms of increasing equity and accessibility to services and reducing the need to travel long distances for health care. However, significant disadvantages need to be considered in the longer term. There is a potential for burnout among health professionals who travel long distances and work long hours, often without adequate peer support or supervision, in order to deliver these services. A further disadvantage, particularly in the use of visiting medical practitioners to provide generalist services, is the lack of development of a sufficiently well-resourced local primary healthcare system in small rural communities. Given the potential negative consequences for both health professionals and rural Australians, the authors caution against the increasing use of FIFO and DIDO services, without the concurrent development of well-resourced, funded and staffed primary healthcare services in rural and remote communities.

  19. Experimental Study of an On-board Fuel Tank Inerting System

    NASA Astrophysics Data System (ADS)

    Wu, Fei; Lin, Guiping; Zeng, Yu; Pan, Rui; Sun, Haoyang

    2017-03-01

    A simulated aircraft fuel tank inerting system was established and experiments were conducted to investigate the performance of the system. The system uses hollow fiber membrane which is widely used in aircraft as the air separation device and a simplified 20% scale multi compartment fuel tank as the inerting object. Experiments were carried out to investigate the influences of different operating parameters on the inerting effectiveness of the system, including NEA (nitrogen-enriched air) flow rate, NEA oxygen concentration, NEA distribution, pressure of bleeding air and fuel load of the tank. Results showed that for the multi compartment fuel tank, concentrated flow washing inerting would cause great differences throughout the distribution of oxygen concentration in the fuel tank, and inerting dead zone would exist. The inerting effectiveness was greatly improved and the ullage oxygen concentration of the tank would reduce to 12% successfully when NEA entered three compartments evenly. The time span of a complete inerting process reduced obviously with increasing NEA flow rate and decreasing NEA concentration, but the trend became weaker gradually. However, the reduction of NEA concentration will decrease the utilization efficiency of the bleeding air. In addition, the time span can also be reduced by raising the pressure of bleeding air, which will improve the bleeding air utilization efficiency at the same time. The time span decreases linearly as the fuel load increases.

  20. System for venting gas from a liquid storage tank

    NASA Astrophysics Data System (ADS)

    Dugan, Regina E.

    1989-07-01

    Gas is vented from a non-cryogenic liquid storage tank while discharging pressurized liquid from a tube into the tank through a plurality of inclined jets, circumferentially spaced about an end of a vent tube positioned within the tube. Each jet is directed toward a central axis of the vent tube, such that the end of the vent tube receives gas from the vessel passing between individual jetstreams, which in combination form a conical shaped barrier to liquid droplets which would otherwise also pass to the vent tube and out the tank. Gas is thus vented through the central tube while pressurized liquid flows in an axially opposite direction in the annulus between the inner vent tube and the outer liquid tube. The system of the present invention is prarticularly well suited for venting gas from a tank being replenished with liquid at a zero or near zero gravity environment. A screen-type liquid acquisition device employing surface tension is provided for withdrawing substantially liquid from the tank. The withdrawn liquid may be resupplied to the liquid tube under pressure supplied by a circulating pump, thereby releasing substantially only gas from the storage tank to reduce the pressure in the tank.

  1. ADM. Tanks: from left to right: fuel oil tank, fuel ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ADM. Tanks: from left to right: fuel oil tank, fuel pump house (TAN-611), engine fuel tank, water pump house, water storage tank. Camera facing northwest. Not edge of shielding berm at left of view. Date: November 25, 1953. INEEL negative no. 9217 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  2. 49 CFR 179.400 - General specification applicable to cryogenic liquid tank car tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... liquid tank car tanks. 179.400 Section 179.400 Transportation Other Regulations Relating to... MATERIALS REGULATIONS SPECIFICATIONS FOR TANK CARS Specification for Cryogenic Liquid Tank Car Tanks and... liquid tank car tanks. ...

  3. 49 CFR 179.100 - General specifications applicable to pressure tank car tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... car tanks. 179.100 Section 179.100 Transportation Other Regulations Relating to Transportation...) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.100 General specifications applicable to pressure tank car tanks. ...

  4. 49 CFR 179.100 - General specifications applicable to pressure tank car tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... car tanks. 179.100 Section 179.100 Transportation Other Regulations Relating to Transportation...) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.100 General specifications applicable to pressure tank car tanks. ...

  5. 49 CFR 179.100 - General specifications applicable to pressure tank car tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... car tanks. 179.100 Section 179.100 Transportation Other Regulations Relating to Transportation... REGULATIONS SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.100 General specifications applicable to pressure tank car tanks. ...

  6. 49 CFR 179.100 - General specifications applicable to pressure tank car tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... car tanks. 179.100 Section 179.100 Transportation Other Regulations Relating to Transportation...) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.100 General specifications applicable to pressure tank car tanks. ...

  7. 27 CFR 27.174 - Tank cars and tank trucks to be sealed.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Tank cars and tank trucks... Tank cars and tank trucks to be sealed. Where a shipment of distilled spirits from customs custody to the distilled spirits plant is made in a tank car or tank truck, all openings affording access to the...

  8. 27 CFR 27.174 - Tank cars and tank trucks to be sealed.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Tank cars and tank trucks... Tank cars and tank trucks to be sealed. Where a shipment of distilled spirits from customs custody to the distilled spirits plant is made in a tank car or tank truck, all openings affording access to the...

  9. 27 CFR 27.174 - Tank cars and tank trucks to be sealed.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Tank cars and tank trucks... Tank cars and tank trucks to be sealed. Where a shipment of distilled spirits from customs custody to the distilled spirits plant is made in a tank car or tank truck, all openings affording access to the...

  10. A storage gas tank is moved to a pallet in the O&C

    NASA Technical Reports Server (NTRS)

    2001-01-01

    KENNEDY SPACE CENTER, Fla. -- An overhead crane in the Operations and Checkout Building lowers one of four gas tanks onto the Spacelab Logistics Double Pallet while workers help guide it. Part of the STS-104 payload, the storage tanks two gaseous oxygen and two gaseous nitrogen -- comprise the high pressure gas assembly that will be attached to the Joint Airlock Module during two spacewalks. The tanks will support future spacewalk operations from the Station and augment the Service Module gas resupply system.

  11. 49 CFR 179.102 - Special commodity requirements for pressure tank car tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... car tanks. 179.102 Section 179.102 Transportation Other Regulations Relating to Transportation... REGULATIONS SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.102 Special commodity requirements for pressure tank car tanks. (a) In addition to...

  12. Tank Closure Progress at the Department of Energy's Idaho National Engineering Laboratory Tank Farm Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quigley, K.D.; Butterworth, St.W.; Lockie, K.A.

    2008-07-01

    Significant progress has been made at the U.S. Department of Energy (DOE) Idaho National Laboratory (INL) to empty, clean and close radioactive liquid waste storage tanks at the Idaho Nuclear Technology and Engineering Center (INTEC) Tank Farm Facility (TFF). The TFF includes eleven 1,135.6-kL (300,000-gal) underground stainless steel storage tanks and four smaller, 113.5-kL (30,000-gal) stainless steel tanks, along with tank vaults, interconnecting piping, and ancillary equipment. The TFF tanks have historically been used to store a variety of radioactive liquid waste, including wastes associated with past spent nuclear fuel reprocessing. Although four of the large storage tanks remain inmore » use for waste storage, the other seven 1,135.6-kL (300,000-gal) tanks and the four 113.5-kL (30,000-gal) tanks have been emptied of waste, cleaned and filled with grout. A water spray cleaning system was developed and deployed to clean internal tank surfaces and remove remaining tank wastes. The cleaning system was effective in removing all but a very small volume of solid residual waste particles. Recent issuance of an Amended Record of Decision (ROD) in accordance with the National Environmental Policy Act, and a Waste Determination complying with Section 3116 of the Ronald W. Reagan National Defense Authorization Act (NDAA) for Fiscal Year 2005, has allowed commencement of grouting activities on the cleaned tanks. The first three 113.5-kL (30,000-gal) tanks were grouted in the Fall of 2006 and the fourth tank and the seven 1,135.6-kL (300,000-gal) tanks were filled with grout in 2007 to provide long-term stability. It is currently planned that associated tank valve boxes and interconnecting piping, will be stabilized with grout as early as 2008. (authors)« less

  13. [Working style among regular general practitioners and other doctors in the out-of-hours services].

    PubMed

    Sandvik, Hogne; Hunskår, Steinar

    2010-01-28

    RGPs (regular general practitioners) are obliged to take on duties in the out-of-hours services in Norway, but they actually perform less than half of this work. We wished to compare remuneration claims for out-of-hours work from RGPs with those from other doctors. The Norwegian Labour and Welfare administration provided information about all doctors working in the out-of-hours services in Norway in 2006 (4 729 of whom 2 220 were RGPs) and coupled this with the remuneration they had claimed in this period. RGPs had 46.6 % of all patient contacts in the out-of-hours services, but more telephone contacts (57.4 %) and simple/short contacts (50.7 %) than other doctors. Other doctors had most contacts in the largest (59.8 %) and most central (56.7 %) municipalities and used general and unspecific diagnoses more often than the RGPs (12.6 % of all consultations vs. 11.0 %). Older doctors used fewer fees than younger doctors, but otherwise the total number of fees only differed slightly between various groups of doctors. Newly qualified doctors serving their compulsory practice period claimed extra remuneration for long consultations in 41.2 % of the cases, RGPs who are also general practice specialists in 20.2 % of cases, and other doctors in 35.7 % of the consultations. RGPs wrote sick notes more often (7.1 % of consultations) than newly qualified doctors (5.7 %) and other doctors (6.6 %). General practice specialists wrote sick notes most often (7.4 %). Experienced RGPs and general practice specialists spend less time per patient than other doctors in the out-of-hours services.

  14. Think tank (1) - Its definition and the overseas situation

    NASA Astrophysics Data System (ADS)

    Obara, Michio

    The definition as organization is that 1) the think tank should be policy oriented and propose the current issues, 2) it should be interdisciplinary and future oriented, and 3) it should be independent without any outside interference upon it. It is divided into three types in terms of business activity; 1) policy proposing, 2) R&D undertaking and 3) business consulting think tanks. Historically the U.S. has been leading the world because the first think tank was born in this country, and three types of think tanks have brought out the mature business undertakings there. Most of the countries other than the U.S. has held policy proposing type think tanks. The notable think tanks are Brookings Research Institute, Rand Research Institute, Battelle Memorial Institute, Arthur D. Little Co. Ltd. SRI International in the U.S.A., IFO Economic Research Institute, German Economic Research Institute in Germany, France International Relations Research Institute in France, Royal International Relations Research institute, International Strategic Matters Research Institute in the U.K., and Korean Development Research Institute, Korean industrial Research Institute in Korea. All of these have been active in the areas of politics, economics, industry and technology.

  15. Durability of foam insulation for LH2 fuel tanks of future subsonic transports

    NASA Technical Reports Server (NTRS)

    Sharpe, E. L.; Helenbrook, R. G.

    1979-01-01

    Organic foams were tested to determine their suitability for insulating liquid hydrogen tanks of subsonic aircraft. The specimens, including nonreinforced foams and foams with chopped glass reinforcements, flame retardants, and vapor barriers, were scaled to simulate stress conditions in large tanks. The tests were conducted within aluminum tank compartments filled with liquid hydrogen and the boil-off rate was used as the criterion of thermal performance. It was found that while all insulations deteriorated with increased cycles, two nonreinforced polyurethane foams showed no structural deterioration after 4200 thermal cycles (equivalent to 15 years of airline service). It was also found that fiberglass reinforcement and flame retardants impaired thermal performance and reduced useful life of the foams. Vapor barriers enhanced structural integrity without any deterioration in thermal properties.

  16. Out-of-pocket expenditure by private households for dental services - empirical evidence from Austria.

    PubMed

    Sanwald, Alice; Theurl, Engelbert

    2016-12-01

    Dental services differ from other health services in several dimensions. One important difference is that a substantial share of costs of dental services-especially costs beyond routine dental treatment-is paid directly by the patient out-of-pocket. This study analyses the socio-economic determinants of out-of-pocket expenditure for dental services (OOPE) in Austria at the household level. Cross-sectional information on OOPE and household characteristics provided by the Austrian household budget survey 2009/10 was analysed. A two-part model (Logit/GLM) and one-part GLM was applied. The probability of OOPE is strongly affected by the life cycle (structure) of the household. It is higher for higher age classes, higher income, and partially higher levels of education. The type of public insurance has an influence on expenditure probability while the existence of private health insurance has no significant effect. In contrast to the highly statistically significant coefficients in the first stage, the covariates of the second stage remain predominantly insignificant. According to the results, the level of expenditure is driven mainly by the level of education and income. The results of the one-part GLM confirm the results of the two-part model. The results allow new insights into the determinants of OOPE for dental care. The household level turns out to be an adequate basis to study the determinants of OOPE, although caution should be applied before jumping to conclusions for the individual level.

  17. 49 CFR 179.102 - Special commodity requirements for pressure tank car tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... car tanks. 179.102 Section 179.102 Transportation Other Regulations Relating to Transportation...) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.102 Special commodity requirements for pressure tank car tanks. (a) In addition to §§ 179.100 and...

  18. 49 CFR 179.102 - Special commodity requirements for pressure tank car tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... car tanks. 179.102 Section 179.102 Transportation Other Regulations Relating to Transportation...) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.102 Special commodity requirements for pressure tank car tanks. (a) In addition to §§ 179.100 and...

  19. 49 CFR 179.102 - Special commodity requirements for pressure tank car tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... car tanks. 179.102 Section 179.102 Transportation Other Regulations Relating to Transportation...) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.102 Special commodity requirements for pressure tank car tanks. (a) In addition to §§ 179.100 and...

  20. Genome-wide scan of job-related exhaustion with three replication studies implicate a susceptibility variant at the UST gene locus

    PubMed Central

    Sulkava, Sonja; Ollila, Hanna M.; Ahola, Kirsi; Partonen, Timo; Viitasalo, Katriina; Kettunen, Johannes; Lappalainen, Maarit; Kivimäki, Mika; Vahtera, Jussi; Lindström, Jaana; Härmä, Mikko; Puttonen, Sampsa; Salomaa, Veikko; Paunio, Tiina

    2013-01-01

    Job-related exhaustion is the core dimension of burnout, a work-related stress syndrome that has several negative health consequences. In this study, we explored the molecular genetic background of job-related exhaustion. A genome-wide analysis of job-related exhaustion was performed in the GENMETS subcohort (n = 1256) of the Finnish population-based Health 2000 study. Replication analyses included an analysis of the strongest associations in the rest of the Health 2000 sample (n = 1660 workers) and in three independent populations (the FINRISK population cohort, n = 10 753; two occupational cohorts, total n = 1451). Job-related exhaustion was ascertained using a standard self-administered questionnaire (the Maslach Burnout Inventory (MBI)-GS exhaustion scale in the Health 2000 sample and the occupational cohorts) or a single question (FINRISK). A variant located in an intron of UST, uronyl-2-sulfotransferase (rs13219957), gave the strongest statistical evidence in the initial genome-wide study (P = 1.55 × 10−7), and was associated with job-related exhaustion in all the replication sets (P < 0.05; P = 6.75 × 10−7 from the meta-analysis). Consistent with studies of mood disorders, individual common genetic variants did not have any strong effect on job-related exhaustion. However, the nominally significant signals from the allelic variant of UST in four separate samples suggest that this variant might be a weak risk factor for job-related exhaustion. Together with the previously reported associations of other dermatan/chondroitin sulfate genes with mood disorders, these results indicate a potential molecular pathway for stress-related traits and mark a candidate region for further studies of job-related and general exhaustion. PMID:23620144

  1. 40 CFR 280.12 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... physical and chemical properties upon contact with one another for the design life of the tank system under... reason of thorough knowledge of the physical sciences and the principles of engineering and mathematics... UST systems located on the same property where the stored heating oil is used. Operational life refers...

  2. 40 CFR 280.106 - Local government guarantee.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Local government guarantee. 280.106... STORAGE TANKS (UST) Financial Responsibility § 280.106 Local government guarantee. (a) A local government... requirements of this section. The guarantor must be either the state in which the local government owner or...

  3. 40 CFR 280.106 - Local government guarantee.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Local government guarantee. 280.106... STORAGE TANKS (UST) Financial Responsibility § 280.106 Local government guarantee. (a) A local government... requirements of this section. The guarantor must be either the state in which the local government owner or...

  4. 40 CFR 280.105 - Local government financial test.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 28 2012-07-01 2012-07-01 false Local government financial test. 280... STORAGE TANKS (UST) Financial Responsibility § 280.105 Local government financial test. (a) A local government owner or operator may satisfy the requirements of § 280.93 by passing the financial test specified...

  5. 40 CFR 280.106 - Local government guarantee.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 28 2012-07-01 2012-07-01 false Local government guarantee. 280.106... STORAGE TANKS (UST) Financial Responsibility § 280.106 Local government guarantee. (a) A local government... requirements of this section. The guarantor must be either the state in which the local government owner or...

  6. 40 CFR 280.106 - Local government guarantee.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 27 2014-07-01 2014-07-01 false Local government guarantee. 280.106... STORAGE TANKS (UST) Financial Responsibility § 280.106 Local government guarantee. (a) A local government... requirements of this section. The guarantor must be either the state in which the local government owner or...

  7. 40 CFR 280.105 - Local government financial test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 27 2014-07-01 2014-07-01 false Local government financial test. 280... STORAGE TANKS (UST) Financial Responsibility § 280.105 Local government financial test. (a) A local government owner or operator may satisfy the requirements of § 280.93 by passing the financial test specified...

  8. INDOOR AIR SAMPLING, SUB-SLAB VAPOR SAMPLING, AND SLAB AIR-PERMEABILITY TESTING AT THE RAYMARK SITE

    EPA Science Inventory

    By 2005, U.S. EPA and its state, tribal and local partners must assess, reduce, and/or control the risk to human health and the environment at more than 374,000 contaminated Superfund, RCRA, underground storage tank (UST), brownfield and oil sites. U.S. EPA is currently developi...

  9. INDOOR AIR SAMPLING, SUB-SLAB VAPOR SAMPLING, AND SLAB AIR PERMEABILITY TESTING AT THE RAYMARK SITE

    EPA Science Inventory

    By 2005, U.S. EPA and its state, tribal and local partners must assess, reduce, and/or control the risk to human health and the environment at more than 374,000 contaminated Superfund, RCRA, underground storage tank (UST), brownfield and oil sites. U.S. EPA is currently developi...

  10. 12 CFR 716.13 - Exception to opt out requirements for service providers and joint marketing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Exception to opt out requirements for service providers and joint marketing. 716.13 Section 716.13 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING CREDIT UNIONS PRIVACY OF CONSUMER FINANCIAL INFORMATION Exceptions § 716.13 Exception to opt out requirements for servic...

  11. 12 CFR 40.13 - Exception to opt out requirements for service providers and joint marketing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 1 2010-01-01 2010-01-01 false Exception to opt out requirements for service providers and joint marketing. 40.13 Section 40.13 Banks and Banking COMPTROLLER OF THE CURRENCY, DEPARTMENT OF THE TREASURY PRIVACY OF CONSUMER FINANCIAL INFORMATION Exceptions § 40.13 Exception to opt out requirements for service providers and join...

  12. 12 CFR 573.13 - Exception to opt out requirements for service providers and joint marketing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Exception to opt out requirements for service providers and joint marketing. 573.13 Section 573.13 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY PRIVACY OF CONSUMER FINANCIAL INFORMATION Exceptions § 573.13 Exception to opt out requirements for service providers and...

  13. 49 CFR 179.500 - Specification DOT-107A * * * * seamless steel tank car tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... car tanks. 179.500 Section 179.500 Transportation Other Regulations Relating to Transportation...) SPECIFICATIONS FOR TANK CARS Specification for Cryogenic Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A) § 179.500 Specification DOT-107A * * * * seamless steel tank car tanks. ...

  14. 49 CFR 179.101 - Individual specification requirements applicable to pressure tank car tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... to pressure tank car tanks. 179.101 Section 179.101 Transportation Other Regulations Relating to... MATERIALS REGULATIONS SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT... tank car tanks. Editorial Note: At 66 FR 45186, Aug. 28, 2001, an amendment published amending a table...

  15. 49 CFR 179.400 - General specification applicable to cryogenic liquid tank car tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... liquid tank car tanks. 179.400 Section 179.400 Transportation Other Regulations Relating to... (CONTINUED) SPECIFICATIONS FOR TANK CARS Specification for Cryogenic Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A) § 179.400 General specification applicable to cryogenic liquid tank car...

  16. 49 CFR 179.500 - Specification DOT-107A * * * * seamless steel tank car tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... car tanks. 179.500 Section 179.500 Transportation Other Regulations Relating to Transportation... REGULATIONS SPECIFICATIONS FOR TANK CARS Specification for Cryogenic Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A) § 179.500 Specification DOT-107A * * * * seamless steel tank car tanks. ...

  17. 49 CFR 179.500 - Specification DOT-107A * * * * seamless steel tank car tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... car tanks. 179.500 Section 179.500 Transportation Other Regulations Relating to Transportation...) SPECIFICATIONS FOR TANK CARS Specification for Cryogenic Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A) § 179.500 Specification DOT-107A * * * * seamless steel tank car tanks. ...

  18. 49 CFR 179.500 - Specification DOT-107A * * * * seamless steel tank car tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... car tanks. 179.500 Section 179.500 Transportation Other Regulations Relating to Transportation...) SPECIFICATIONS FOR TANK CARS Specification for Cryogenic Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A) § 179.500 Specification DOT-107A * * * * seamless steel tank car tanks. ...

  19. 49 CFR 179.400 - General specification applicable to cryogenic liquid tank car tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... liquid tank car tanks. 179.400 Section 179.400 Transportation Other Regulations Relating to... (CONTINUED) SPECIFICATIONS FOR TANK CARS Specification for Cryogenic Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A) § 179.400 General specification applicable to cryogenic liquid tank car...

  20. 49 CFR 179.400 - General specification applicable to cryogenic liquid tank car tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... liquid tank car tanks. 179.400 Section 179.400 Transportation Other Regulations Relating to... (CONTINUED) SPECIFICATIONS FOR TANK CARS Specification for Cryogenic Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A) § 179.400 General specification applicable to cryogenic liquid tank car...

  1. View of tanks T18 and T19 with redwood tanks to ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View of tanks T18 and T19 with redwood tanks to right. Old rain shed (Building No. 43) can be seen behind the tanks. Ground catchment can be seen at left in background. - Hawaii Volcanoes National Park Water Collection System, Hawaii Volcanoes National Park, Volcano, Hawaii County, HI

  2. 40 CFR 280.104 - Local government bond rating test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Local government bond rating test. 280... STORAGE TANKS (UST) Financial Responsibility § 280.104 Local government bond rating test. (a) A general purpose local government owner or operator and/or local government serving as a guarantor may satisfy the...

  3. 46 CFR 153.250 - Double-bottom and deep tanks as cargo tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Double-bottom and deep tanks as cargo tanks. 153.250... Equipment Cargo Tanks § 153.250 Double-bottom and deep tanks as cargo tanks. Except in those cases in which Commandant (CG-522) specifically approves another arrangement, such as a double-bottom or deep tank as a...

  4. 46 CFR 153.250 - Double-bottom and deep tanks as cargo tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Double-bottom and deep tanks as cargo tanks. 153.250... Equipment Cargo Tanks § 153.250 Double-bottom and deep tanks as cargo tanks. Except in those cases in which Commandant (CG-ENG) specifically approves another arrangement, such as a double-bottom or deep tank as a...

  5. 46 CFR 153.250 - Double-bottom and deep tanks as cargo tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Double-bottom and deep tanks as cargo tanks. 153.250... Equipment Cargo Tanks § 153.250 Double-bottom and deep tanks as cargo tanks. Except in those cases in which Commandant (CG-522) specifically approves another arrangement, such as a double-bottom or deep tank as a...

  6. 46 CFR 153.250 - Double-bottom and deep tanks as cargo tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Double-bottom and deep tanks as cargo tanks. 153.250... Equipment Cargo Tanks § 153.250 Double-bottom and deep tanks as cargo tanks. Except in those cases in which Commandant (CG-ENG) specifically approves another arrangement, such as a double-bottom or deep tank as a...

  7. 46 CFR 153.250 - Double-bottom and deep tanks as cargo tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Double-bottom and deep tanks as cargo tanks. 153.250... Equipment Cargo Tanks § 153.250 Double-bottom and deep tanks as cargo tanks. Except in those cases in which Commandant (CG-ENG) specifically approves another arrangement, such as a double-bottom or deep tank as a...

  8. 49 CFR 179.301 - Individual specification requirements for multi-unit tank car tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...-unit tank car tanks. 179.301 Section 179.301 Transportation Other Regulations Relating to... (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Multi-Unit Tank Car Tanks (Classes DOT-106A and 110AW) § 179.301 Individual specification requirements for multi-unit tank car tanks. (a) In addition to...

  9. 49 CFR 179.301 - Individual specification requirements for multi-unit tank car tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-unit tank car tanks. 179.301 Section 179.301 Transportation Other Regulations Relating to... MATERIALS REGULATIONS SPECIFICATIONS FOR TANK CARS Specifications for Multi-Unit Tank Car Tanks (Classes DOT-106A and 110AW) § 179.301 Individual specification requirements for multi-unit tank car tanks. (a) In...

  10. 49 CFR 179.301 - Individual specification requirements for multi-unit tank car tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...-unit tank car tanks. 179.301 Section 179.301 Transportation Other Regulations Relating to... (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Multi-Unit Tank Car Tanks (Classes DOT-106A and 110AW) § 179.301 Individual specification requirements for multi-unit tank car tanks. (a) In addition to...

  11. 49 CFR 179.301 - Individual specification requirements for multi-unit tank car tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...-unit tank car tanks. 179.301 Section 179.301 Transportation Other Regulations Relating to... (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Multi-Unit Tank Car Tanks (Classes DOT-106A and 110AW) § 179.301 Individual specification requirements for multi-unit tank car tanks. (a) In addition to...

  12. Fuel tank integrity research : fuel tank analyses and test plans

    DOT National Transportation Integrated Search

    2013-04-15

    The Federal Railroad Administrations Office of Research : and Development is conducting research into fuel tank : crashworthiness. Fuel tank research is being performed to : determine strategies for increasing the fuel tank impact : resistance to ...

  13. 49 CFR 179.500 - Specification DOT-107A * * * * seamless steel tank car tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Specification DOT-107A * * * * seamless steel tank...) SPECIFICATIONS FOR TANK CARS Specification for Cryogenic Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A) § 179.500 Specification DOT-107A * * * * seamless steel tank car tanks. ...

  14. 75 FR 70241 - Compatibility of Underground Storage Tank Systems With Biofuel Blends

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-17

    ..., Room 3334, 1301 Constitution Ave., NW., Washington, DC. The Public Reading Room is open from 8:30 a.m... Reading Room is (202) 566-1744, and the telephone number for the UST Docket is (202) 566-0270. FOR FURTHER... that there are other reasonable ways to demonstrate compatibility. With that in mind, EPA is...

  15. Tank Closure Progress at the Department of Energy's Idaho National Engineering Laboratory Tank Farm Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lockie, K.A.; Suttora, L.C.; Quigley, K.D.

    2007-07-01

    Significant progress has been made at the U.S. Department of Energy (DOE) Idaho National Laboratory (INL) to clean and close emptied radioactive liquid waste storage tanks at the Idaho Nuclear Technology and Engineering Center (INTEC) Tank Farm Facility (TFF). The TFF includes eleven 1,135.6-kL (300,000-gal) underground stainless steel storage tanks and four smaller, 113.5-kL (30,000-gal) stainless steel tanks, along with tank vaults, interconnecting piping, and ancillary equipment. The TFF tanks have historically been used to store a variety of radioactive liquid waste, including wastes associated with past spent nuclear fuel reprocessing. Although four of the large storage tanks remain inmore » use for waste storage, the other seven 1,135.6-kL (300,000-gal) tanks and the four 113.5-kL (30,000-gal) tanks have been emptied of waste and cleaned in preparation of final closure. A water spray cleaning system was developed and deployed to clean internal tank surfaces and remove remaining tank wastes. The cleaning system was effective in removing all but a very small volume of solid residual waste particles. Recent issuance of an Amended Record of Decision (ROD) in accordance with the National Environmental Policy Act, and a Waste Determination complying with Section 3116 of the Ronald W. Reagan National Defense Authorization Act (NDAA) for Fiscal Year 2005, has allowed commencement of grouting activities on the cleaned tanks. In November 2006, three of the 113.5-kL (30,000-gal) tanks were filled with grout to provide long-term stability. It is currently planned that all seven cleaned 1,135.6-kL (300,000-gal) tanks, as well as the four 113.5-kL (30,000-gal) tanks and all associated tank vaults and interconnecting piping, will be stabilized with grout as early as 2008. (authors)« less

  16. Design criteria monograph for metal tanks and tank components

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Significant elements in detail tank design are wall and end structures, weld joints at bulkhead and attachment junctures, and ports and access openings. Additional design considerations are influence and effect of fabrication processes on tank component design, and finally, testing and inspection that are required to establish confidence in tank design.

  17. A sub-tank water-saving drinking water station

    NASA Astrophysics Data System (ADS)

    Zhang, Ting

    2017-05-01

    "Thousands of boiling water" problem has been affecting people's quality of life and good health, and now most of the drinking fountains cannot effectively solve this problem, at the same time, ordinary drinking water also has high energy consumption, there are problems such as yin and yang water. Our newly designed dispenser uses a two-tank heating system. Hot water after heating, into the insulation tank for insulation, when the water tank in the water tank below a certain water level, the cold water and then enter the heating tank heating. Through the water flow, tank volume and other data to calculate the time required for each out of water, so as to determine the best position of the water level control, summed up the optimal program, so that water can be continuously uninterrupted supply. Two cans are placed up and down the way, in the same capacity on the basis of the capacity of the container, the appropriate to reduce its size, and increase the bottom radius, reduce the height of its single tank to ensure that the overall height of two cans compared with the traditional single change. Double anti-dry design, to ensure the safety of the use of drinking water. Heating tank heating circuit on and off by the tank of the float switch control, so that the water heating time from the tank water level control, to avoid the "thousands of boiling water" generation. The entry of cold water is controlled by two solenoid valves in the inlet pipe, and the opening and closing of the solenoid valve is controlled by the float switch in the two tanks. That is, the entry of cold water is determined by the water level of the two tanks. By designing the control scheme cleverly, Yin and yang water generation. Our design completely put an end to the "thousands of boiling water", yin and yang water, greatly improving the drinking water quality, for people's drinking water safety provides a guarantee, in line with the concept of green and healthy development. And in the small

  18. Use of Compound-Specific Stable Isotope Analysis to Distinguish between Vapor Intrusion and Indoor Sources of VOC

    DTIC Science & Technology

    2013-12-01

    trichloroethylene USEPA U.S. Environmental Protection Agency UST underground storage tank V-PDB Vienna - Pee Dee Belemnite ACRONYMS AND...compound (e.g., trichloroethylene [TCE]) can vary as a result of differences in their source material or compound synthesis or due to transformation... trichloroethylene [TCE], and benzene) that commonly drive VI investigations; 2) development of a protocol for application of CSIA in VI investigations; and 3

  19. Development and Testing of a Mobile Platform for Tank Remediation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nance, T.A.

    2001-01-16

    The Department of Energy (DOE) is committed to removing millions of gallons of high level radioactive waste from waste storage tanks at the Savannah River Site (SRS). SRS was the first site in the DOE complex to have emptied and closed high level waste tanks. Tank closure at the Site is now progressing to tanks containing waste composed of liquid and large deposits of solids, including a tank that has a potential ''heel''. A heel is a hardened mass of solid waste material spread across the tank bottom. Tank closure requires breaking up this heel and moving the material tomore » the intake of a pumping system for transfer from the tank. In the past, overhead spray systems have been used with some success at moving waste. But the limited number of risers restricts the coverage area of the overhead spray system. Therefore, a floor- level spray system will be used to separate manageable size chunks of the material from the heel. The chunks will be guided into the pump's intake to be remove from the tank. The floor-level spray system movement will be accomplished by using a mobile platform, a crawler, which provides transport to nearly every point on the tank floor. Transport of the spray system will allow the system to ''corral'' the waste away from the tank walls and control the movement of the material across the tank floor. Because the available access riser is small, and a wide crawler platform is required to support the spray system, the crawler's frame must fold to enter the tank. After entry into the tank, the crawler unfolds on the tank floor using the crawler drive tracks to expand the frame and position the mobile platform under the entry riser. The spray system will then be lowered separately through the entry riser and mated onto the crawler on the tank floor. The crawler and spray system are tethered and controlled remotely by personnel at the control station. Motorized cable reels will also be remotely controlled to pay out, retrieve, and manage the

  20. 46 CFR 167.15-40 - Integral fuel oil tank examinations-T/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... vessel shall have the tanks cleaned out and gas freed as necessary to permit internal examination of the... examination of the fuel tanks of each vessel during an internal structural examination at intervals not to... examined if the marine inspector is able to determine by external examination that the general condition of...

  1. 49 CFR 179.101 - Individual specification requirements applicable to pressure tank car tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... to pressure tank car tanks. 179.101 Section 179.101 Transportation Other Regulations Relating to... (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.101 Individual specification requirements applicable to pressure tank car...

  2. 49 CFR 179.101 - Individual specification requirements applicable to pressure tank car tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... to pressure tank car tanks. 179.101 Section 179.101 Transportation Other Regulations Relating to... (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.101 Individual specification requirements applicable to pressure tank car...

  3. 49 CFR 179.101 - Individual specification requirements applicable to pressure tank car tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... to pressure tank car tanks. 179.101 Section 179.101 Transportation Other Regulations Relating to... (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.101 Individual specification requirements applicable to pressure tank car...

  4. Tank 241-C-112 vapor sampling and analysis tank characterization report. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huckaby, J.L.

    1995-05-31

    Tank 241-C-112 headspace gas and vapor samples were collected and analyzed to help determine the potential risks to tank farm workers due to fugitive emissions from the tank. The drivers and objectives of waste tank headspace sampling and analysis are discussed in {open_quotes}Program Plan for the Resolution of Tank Vapor Issues.{close_quotes} Tank 241-C-112 was vapor sampled in accordance with {open_quotes}Data Quality Objectives for Generic In-Tank Health and Safety Issue Resolution.{close_quotes}

  5. Results of Hg speciation testing on tank 39 and 1Q16 tank 50 samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bannochie, C. J.

    2016-03-07

    The Savannah River National Laboratory (SRNL) was tasked with preparing and shipping samples for Hg speciation by Eurofins Frontier Global Sciences, Inc. in Seattle, WA on behalf of the Savannah River Remediation (SRR) Mercury Task Team.i,ii The seventeenth shipment of samples was designated to include two Tank 39 samples and the 1Q16 Tank 50 Quarterly WAC sample. The surface Tank 39 sample was pulled at 262.1” from the tank bottom, and the depth Tank 39 sample was pulled at 95” from the tank bottom. The 1Q16 Tank 50 WAC sample was drawn from the 1-L variable depth sample received bymore » SRNL.« less

  6. Liquid rocket metal tanks and tank components

    NASA Technical Reports Server (NTRS)

    Wagner, W. A.; Keller, R. B. (Editor)

    1974-01-01

    Significant guidelines are presented for the successful design of aerospace tanks and tank components, such as expulsion devices, standpipes, and baffles. The state of the art is reviewed, and the design criteria are presented along with recommended practices. Design monographs are listed.

  7. 40 CFR 280.110 - Reporting by owner or operator.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... STORAGE TANKS (UST) Financial Responsibility § 280.110 Reporting by owner or operator. (a) An owner or operator must submit the appropriate forms listed in § 280.111(b) documenting current evidence of financial... proceeding under Title 11 (Bankruptcy), U.S. Code, naming a provider of financial assurance as a debtor, (ii...

  8. Evaluation of milk quality in delivering sterilized milk with soft tank transportation system.

    PubMed

    Tsukamoto, C; Rula, Sa; Asano, H; Ando, K

    2009-09-01

    A new transportation system is proposed recently to improve the defects of liquid transportation by tank trucks. This method is called "soft tank transportation system"; a driver installs a sac-like container (soft tank), which is made from a tarpaulin with high-pressure resistant-waterproof zippers, in a general cargo vehicle. To evaluate the quality of sterilized milk by using the soft tank transportation system, ground and marine transportation for a long distance which took about 36 h from the shipper's loading to the receiver's unloading in a high-temperature summer season (average outside temperature was 33.4 degrees C) were carried out. Although the difference of milk temperature before and after the delivery varied from -0.7 to +1.4 degrees C, there was no difference in milk quality (fat, nonfat solids, total dissolved solids, and pH) and no coliform bacteria were detected. It can be evaluated that sterilized milk was carried in keeping good conditions by soft tank transportation system.

  9. DETERMINING HOW VAPOR PHASE MTBE REACHES GROUND WATER

    EPA Science Inventory

    EPA Region 2 and ORD have funded a RARE project for FY 2005/2006 to evaluate the prospects that MTBE (and other fuel components) in vapors that escape from an underground storage tank (UST) can find its way to ground water produced by monitoring wells at a gasoline filling statio...

  10. 49 CFR 179.101 - Individual specification requirements applicable to pressure tank car tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... to pressure tank car tanks. 179.101 Section 179.101 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109...

  11. 49 CFR 179.221 - Individual specification requirements applicable to tank car tanks consisting of an inner...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Non-Pressure Tank Car Tanks (Classes DOT-111AW and 115AW) § 179.221 Individual specification... to tank car tanks consisting of an inner container supported within an outer shell. 179.221 Section...

  12. 49 CFR 179.221 - Individual specification requirements applicable to tank car tanks consisting of an inner...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Non-Pressure Tank Car Tanks (Classes DOT-111AW and 115AW) § 179.221 Individual specification... to tank car tanks consisting of an inner container supported within an outer shell. 179.221 Section...

  13. 76 FR 76684 - Idaho: Tentative Approval of State Underground Storage Tank Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-08

    .... Skyline, Suite B, Idaho Falls, ID 83402 from 10 a.m. to 12 p.m. and 1 p.m. to 4 p.m.; and 6. IDEQ Lewiston... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 281 [EPA-R10-UST-2011-0896; FRL-9502-6] Idaho...). ACTION: Proposed rule. SUMMARY: The State of Idaho has applied for final approval of its Underground...

  14. Developing NDE Techniques for Large Cryogenic Tanks - Year 2 Report

    NASA Technical Reports Server (NTRS)

    Arens, Ellen; youngquist, Robert; McFall, Judith; Simmons, Stephen

    2010-01-01

    The Shuttle Program requires very large cryogenic ground storage tanks in which to store liquid oxygen and hydrogen. The existing Launch Complex-39 Pad tanks, which will be passed onto future launch programs, are over 40 years old and have received minimal refurbishment and only external inspections over the years. The majority of the structure is inaccessible without a full system drain of cryogenic liquid and insulation in the annular region. It was previously thought that there was a limit to the number of temperature cycles that the tanks could handle due to possible insulation compaction before undergoing a costly and time consuming complete overhaul; therefore the tanks were not drained and performance issues with these tanks, specifically the Pad B LH2 tank, were accepted. There is a need and an opportunity, as the Shuttle program ends and work to upgrade the launch pad progresses, to develop innovative non-destructive evaluation (NDE) techniques to analyze the current tanks. Techniques are desired that can aid in determining the extent of refurbishment required to keep the tanks in service for another 20+ years. A non-destructive technique would also be a significant aid in acceptance testing of new and refurbished tanks, saving significant time and money, if corrective actions can be taken before cryogen is introduced to the systems. Year one of this project concentrated on analysis of the current tanks located at LC-39 while cryogen was present. Year two of this project concentrated on analysis of detectable thermal variations on the outer surface of the tanks as the cryogen was drained and the inner vessel warmed to ambient conditions. Two techniques have been deployed in the field to monitor the tank. The first consisted of a displacement sensor to monitor for any expansions at the base of the tank during warm-up that could indicate a compaction issue with the insulation. The second technique was continued thermal monitoring of the tank through and

  15. DEMONSTRATION AND EVALUATION OF TECHNOLOGIES FOR DETERMINING THE SUITABILITY OF USTS FOR UPGRADING WITH CATHODIC PROTECTION

    EPA Science Inventory

    Field applications of three alternate technologies for assessing the suitability of underground storage tanks for upgrading by the addition of cathodic protection were observed and documented. The technologies were applied to five existing underground storage tanks that were slat...

  16. Practical application of opt-out recruitment methods in two health services research studies.

    PubMed

    Miller, Christopher J; Burgess, James F; Fischer, Ellen P; Hodges, Deborah J; Belanger, Lindsay K; Lipschitz, Jessica M; Easley, Siena R; Koenig, Christopher J; Stanley, Regina L; Pyne, Jeffrey M

    2017-04-14

    Participant recruitment is an ongoing challenge in health research. Recruitment may be especially difficult for studies of access to health care because, even among those who are in care, people using services least often also may be hardest to contact and recruit. Opt-out recruitment methods (in which potential participants are given the opportunity to decline further contact about the study (opt out) following an initial mailing, and are then contacted directly if they have not opted out within a specified period) can be used for such studies. However, there is a dearth of literature on the effort needed for effective opt-out recruitment. In this paper we describe opt-out recruitment procedures for two studies on access to health care within the U.S. Department of Veterans Affairs. We report resource requirements for recruitment efforts (number of opt-out packets mailed and number of phone calls made). We also compare the characteristics of study participants to potential participants via t-tests, Fisher's exact tests, and chi-squared tests. Recruitment rates for our two studies were 12 and 21%, respectively. Across multiple study sites, we had to send between 4.3 and 9.2 opt-out packets to recruit one participant. The number of phone calls required to arrive at a final status for each potentially eligible Veteran (i.e. study participation or the termination of recruitment efforts) were 2.9 and 6.1 in the two studies, respectively. Study participants differed as expected from the population of potentially eligible Veterans based on planned oversampling of certain subpopulations. The final samples of participants did not differ statistically from those who were mailed opt-out packets, with one exception: in one of our two studies, participants had higher rates of mental health service use in the past year than did those mailed opt-out packets (64 vs. 47%). Our results emphasize the practicality of using opt-out methods for studies of access to health care. Despite

  17. Degradation and Reinforcement of Industrial Gas Tank Support Structures. Thirty-Year Long Monitoring

    NASA Astrophysics Data System (ADS)

    Krentowski, Janusz R.; Knyziak, Piotr

    2017-10-01

    An analysis of reinforced concrete supporting structures of more than a dozen liquid gas tanks mounted on tower support structures located at different sites on Poland’s territory is presented. Stability testing of the degraded structures was carried out over a period of 30 years and pointed out significant defects that prevented safe operation of the tanks containing hazardous medium. Analysing complex stress states, as well as displacements of shell structure components, the authors developed a concept of strengthening the structures. Initial repair works, which had been carried out without proper supervision, failed to meet the mandatory requirements and were not compatible with the original design solutions. After several years of operation of the reinforced structures, their degradation states were assessed again. The next stage of repair works was carried out under the supervision of the authors together with authorized representatives of the investors.

  18. Characterization of the MVST waste tanks located at ORNL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keller, J.M.; Giaquinto, J.M.; Meeks, A.M.

    During the fall of 1996 there was a major effort to sample and analyze the Active Liquid Low-Level Waste (LLLW) tanks at ORNL which include the Melton Valley Storage Tanks (MVST) and the Bethel Valley Evaporator Service Tanks (BVEST). The characterization data summarized in this report was needed to address waste processing options, address concerns of the performance assessment (PA) data for the Waste Isolation Pilot Plant (WIPP), evaluate the characteristics with respect to the waste acceptance criteria (WAC) for WIPP and Nevada Test Site (NTS), address criticality concerns, and meet DOT requirements for transporting the waste. This report onlymore » discusses the analytical characterization data for the MVST waste tanks. The isotopic data presented in this report support the position that fissile isotopes of uranium and plutonium were ``denatured`` as required by administrative controls. In general, MVST sludge was found to be both hazardous by RCRA characteristics and the transuranic alpha activity was well about the limit for TRU waste. The characteristics of the MVST sludge relative to the WIPP WAC limits for fissile gram equivalent, plutonium equivalent activity, and thermal power from decay heat, were estimated from the data in this report and found to be far below the upper boundary for any of the remote-handled transuranic waste requirements for disposal of the waste in WIPP.« less

  19. Contracting out to improve the use of clinical health services and health outcomes in low- and middle-income countries.

    PubMed

    Odendaal, Willem A; Ward, Kim; Uneke, Jesse; Uro-Chukwu, Henry; Chitama, Dereck; Balakrishna, Yusentha; Kredo, Tamara

    2018-04-03

    Contracting out of governmental health services is a financing strategy that governs the way in which public sector funds are used to have services delivered by non-governmental health service providers (NGPs). It represents a contract between the government and an NGP, detailing the mechanisms and conditions by which the latter should provide health care on behalf of the government. Contracting out is intended to improve the delivery and use of healthcare services. This Review updates a Cochrane Review first published in 2009. To assess effects of contracting out governmental clinical health services to non-governmental service provider/s, on (i) utilisation of clinical health services; (ii) improvement in population health outcomes; (iii) improvement in equity of utilisation of these services; (iv) costs and cost-effectiveness of delivering the services; and (v) improvement in health systems performance. We searched CENTRAL, MEDLINE, Embase, NHS Economic Evaluation Database, EconLit, ProQuest, and Global Health on 07 April 2017, along with two trials registers - ClinicalTrials.gov and the International Clinical Trials Registry Platform - on 17 November 2017. Individually randomised and cluster-randomised trials, controlled before-after studies, interrupted time series, and repeated measures studies, comparing government-delivered clinical health services versus those contracted out to NGPs, or comparing different models of non-governmental-delivered clinical health services. Two authors independently screened all records, extracted data from the included studies and assessed the risk of bias. We calculated the net effect for all outcomes. A positive value favours the intervention whilst a negative value favours the control. Effect estimates are presented with 95% confidence intervals. We used the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach to assess the certainty of the evidence and we prepared a Summary of Findings table

  20. Simulation model of stratified thermal energy storage tank using finite difference method

    NASA Astrophysics Data System (ADS)

    Waluyo, Joko

    2016-06-01

    Stratified TES tank is normally used in the cogeneration plant. The stratified TES tanks are simple, low cost, and equal or superior in thermal performance. The advantage of TES tank is that it enables shifting of energy usage from off-peak demand for on-peak demand requirement. To increase energy utilization in a stratified TES tank, it is required to build a simulation model which capable to simulate the charging phenomenon in the stratified TES tank precisely. This paper is aimed to develop a novel model in addressing the aforementioned problem. The model incorporated chiller into the charging of stratified TES tank system in a closed system. The model was developed in one-dimensional type involve with heat transfer aspect. The model covers the main factors affect to degradation of temperature distribution namely conduction through the tank wall, conduction between cool and warm water, mixing effect on the initial flow of the charging as well as heat loss to surrounding. The simulation model is developed based on finite difference method utilizing buffer concept theory and solved in explicit method. Validation of the simulation model is carried out using observed data obtained from operating stratified TES tank in cogeneration plant. The temperature distribution of the model capable of representing S-curve pattern as well as simulating decreased charging temperature after reaching full condition. The coefficient of determination values between the observed data and model obtained higher than 0.88. Meaning that the model has capability in simulating the charging phenomenon in the stratified TES tank. The model is not only capable of generating temperature distribution but also can be enhanced for representing transient condition during the charging of stratified TES tank. This successful model can be addressed for solving the limitation temperature occurs in charging of the stratified TES tank with the absorption chiller. Further, the stratified TES tank can be

  1. 49 CFR 179.100 - General specifications applicable to pressure tank car tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... car tanks. 179.100 Section 179.100 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120...

  2. 49 CFR 179.102 - Special commodity requirements for pressure tank car tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... car tanks. 179.102 Section 179.102 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120...

  3. 49 CFR 179.103 - Special requirements for class 114A * * * tank car tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Special requirements for class 114A * * * tank car...) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.103 Special requirements for class 114A * * * tank car tanks. (a) In addition to the applicable...

  4. 49 CFR 179.103 - Special requirements for class 114A * * * tank car tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Special requirements for class 114A * * * tank car...) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.103 Special requirements for class 114A * * * tank car tanks. (a) In addition to the applicable...

  5. 49 CFR 179.103 - Special requirements for class 114A * * * tank car tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Special requirements for class 114A * * * tank car...) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.103 Special requirements for class 114A * * * tank car tanks. (a) In addition to the applicable...

  6. 49 CFR 179.103 - Special requirements for class 114A * * * tank car tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Special requirements for class 114A * * * tank car... SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.103 Special requirements for class 114A * * * tank car tanks. (a) In addition to the applicable...

  7. 49 CFR 179.201 - Individual specification requirements applicable to non-pressure tank car tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... to non-pressure tank car tanks. 179.201 Section 179.201 Transportation Other Regulations Relating to... MATERIALS REGULATIONS SPECIFICATIONS FOR TANK CARS Specifications for Non-Pressure Tank Car Tanks (Classes... car tanks. ...

  8. 49 CFR 179.201 - Individual specification requirements applicable to non-pressure tank car tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... to non-pressure tank car tanks. 179.201 Section 179.201 Transportation Other Regulations Relating to... (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Non-Pressure Tank Car Tanks (Classes DOT-111AW and 115AW) § 179.201 Individual specification requirements applicable to non-pressure tank car tanks. ...

  9. 49 CFR 179.201 - Individual specification requirements applicable to non-pressure tank car tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... to non-pressure tank car tanks. 179.201 Section 179.201 Transportation Other Regulations Relating to... (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Non-Pressure Tank Car Tanks (Classes DOT-111AW and 115AW) § 179.201 Individual specification requirements applicable to non-pressure tank car tanks. ...

  10. 49 CFR 179.201 - Individual specification requirements applicable to non-pressure tank car tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... to non-pressure tank car tanks. 179.201 Section 179.201 Transportation Other Regulations Relating to... (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Non-Pressure Tank Car Tanks (Classes DOT-111AW and 115AW) § 179.201 Individual specification requirements applicable to non-pressure tank car tanks. ...

  11. 9 CFR 316.14 - Marking tank cars and tank trucks used in transportation of edible products.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Marking tank cars and tank trucks used in transportation of edible products. 316.14 Section 316.14 Animals and Animal Products FOOD SAFETY... CONTAINERS § 316.14 Marking tank cars and tank trucks used in transportation of edible products. Each tank...

  12. Tank vapor mitigation requirements for Hanford Tank Farms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rakestraw, L.D.

    1994-11-15

    Westinghouse Hanford Company has contracted Los Alamos Technical Associates to listing of vapors and aerosols that are or may be emitted from the High Level Waste (HLW) tanks at Hanford. Mitigation requirements under Federal and State law, as well as DOE Orders, are included in the listing. The lists will be used to support permitting activities relative to tank farm ventilation system up-grades. This task is designated Task 108 under MJB-SWV-312057 and is an extension of efforts begun under Task 53 of Purchase Order MPB-SVV-03291 5 for Mechanical Engineering Support. The results of that task, which covered only thirty-nine tanks,more » are repeated here to provide a single source document for vapor mitigation requirements for all 177 HLW tanks.« less

  13. Computational Fluid Dynamics (CFD) Simulations of Jet Mixing in Tanks of Different Scales

    NASA Technical Reports Server (NTRS)

    Breisacher, Kevin; Moder, Jeffrey

    2010-01-01

    For long-duration in-space storage of cryogenic propellants, an axial jet mixer is one concept for controlling tank pressure and reducing thermal stratification. Extensive ground-test data from the 1960s to the present exist for tank diameters of 10 ft or less. The design of axial jet mixers for tanks on the order of 30 ft diameter, such as those planned for the Ares V Earth Departure Stage (EDS) LH2 tank, will require scaling of available experimental data from much smaller tanks, as well designing for microgravity effects. This study will assess the ability for Computational Fluid Dynamics (CFD) to handle a change of scale of this magnitude by performing simulations of existing ground-based axial jet mixing experiments at two tank sizes differing by a factor of ten. Simulations of several axial jet configurations for an Ares V scale EDS LH2 tank during low Earth orbit (LEO) coast are evaluated and selected results are also presented. Data from jet mixing experiments performed in the 1960s by General Dynamics with water at two tank sizes (1 and 10 ft diameter) are used to evaluate CFD accuracy. Jet nozzle diameters ranged from 0.032 to 0.25 in. for the 1 ft diameter tank experiments and from 0.625 to 0.875 in. for the 10 ft diameter tank experiments. Thermally stratified layers were created in both tanks prior to turning on the jet mixer. Jet mixer efficiency was determined by monitoring the temperatures on thermocouple rakes in the tanks to time when the stratified layer was mixed out. Dye was frequently injected into the stratified tank and its penetration recorded. There were no velocities or turbulence quantities available in the experimental data. A commercially available, time accurate, multi-dimensional CFD code with free surface tracking (FLOW-3D from Flow Science, Inc.) is used for the simulations presented. Comparisons are made between computed temperatures at various axial locations in the tank at different times and those observed experimentally. The

  14. 46 CFR 38.05-2 - Design and construction of cargo tanks-general-TB/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... a pressure equal to the setting of the relief valve. (b) The service temperature is the minimum...=Service temperature. t w=Boiling temperature of gas at normal working pressure of tank but not higher than +32 °F. t b=Boiling temperature of gas at atmospheric pressure. (c) Heat transmission studies, where...

  15. 46 CFR 38.05-2 - Design and construction of cargo tanks-general-TB/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... a pressure equal to the setting of the relief valve. (b) The service temperature is the minimum...=Service temperature. t w=Boiling temperature of gas at normal working pressure of tank but not higher than +32 °F. t b=Boiling temperature of gas at atmospheric pressure. (c) Heat transmission studies, where...

  16. Compatibility of the Radio Frequency Mass Gauge with Graphite-Epoxy Composite Tanks

    NASA Technical Reports Server (NTRS)

    Zimmerli, G. A.; Mueller, C. H.

    2015-01-01

    The radio frequency mass gauge (RFMG) is a low-gravity propellant quantity gauge being developed at NASA for possible use in long-duration space missions utilizing cryogenic propellants. As part of the RFMG technology development process, we evaluated the compatibility of the RFMG with a graphite-epoxy composite material used to construct propellant tanks. The key material property that can affect compatibility with the RFMG is the electrical conductivity. Using samples of 8552/IM7 graphite-epoxy composite, we characterized the resistivity and reflectivity over a range of frequencies. An RF impedance analyzer was used to characterize the out-of-plane electrical properties (along the sample thickness) in the frequency range 10 to 1800 MHZ. The resistivity value at 500 MHz was 4.8 ohm-cm. Microwave waveguide measurements of samples in the range 1.7 - 2.6 GHz, performed by inserting the samples into a WR-430 waveguide, showed reflectivity values above 98%. Together, these results suggested that a tank constructed from graphite/epoxy composite would produce good quality electromagnetic tank modes, which is needed for the RFMG. This was verified by room-temperature measurements of the electromagnetic modes of a 2.4 m diameter tank constructed by Boeing from similar graphite-epoxy composite material. The quality factor Q of the tank electromagnetic modes, measured via RF reflection measurements from an antenna mounted in the tank, was typically in the range 400 less than Q less than 3000. The good quality modes observed in the tank indicate that the RFMG is compatible with graphite-epoxy tanks, and thus the RFMG could be used as a low-gravity propellant quantity gauge in such tanks filled with cryogenic propellants.

  17. SINDA/FLUINT Stratified Tank Modeling for Cryrogenic Propellant Tanks

    NASA Technical Reports Server (NTRS)

    Sakowski, Barbara

    2014-01-01

    A general purpose SINDA/FLUINT (S/F) stratified tank model was created to simulate self-pressurization and axial jet TVS; Stratified layers in the vapor and liquid are modeled using S/F lumps.; The stratified tank model was constructed to permit incorporating the following additional features:, Multiple or singular lumps in the liquid and vapor regions of the tank, Real gases (also mixtures) and compressible liquids, Venting, pressurizing, and draining, Condensation and evaporation/boiling, Wall heat transfer, Elliptical, cylindrical, and spherical tank geometries; Extensive user logic is used to allow detailed tailoring - Don't have to rebuilt everything from scratch!!; Most code input for a specific case is done through the Registers Data Block:, Lump volumes are determined through user input:; Geometric tank dimensions (height, width, etc); Liquid level could be input as either a volume percentage of fill level or actual liquid level height

  18. Recommended high-tank temperatures for maintenance of high-tank backup support, Revision 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greager, O.H.

    1964-05-20

    Purpose of this note is to recommend revised curves for the high-tank temperature required to maintain adequate high-tank backup support at the six small reactors. Compliance with the conditions shown on these curves will ensure adequate high-tank flow rates following the simultaneous loss of electric and steam power.

  19. Remaining Sites Verification Package for the 100-B-20, 1716-B Maintenance Garage Underground Tank, Waste Site Reclassification Form 2006-019

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    L. M. Dittmer

    2006-09-27

    The 100-B-20 waste site, located in the 100-BC-1 Operable Unit of the Hanford Site, consisted of an underground oil tank that once serviced the 1716-B Maintenance Garage. The selected action for the 100-B-20 waste site involved removal of the oil tanks and their contents and demonstrating through confirmatory sampling that all cleanup goals have been met. In accordance with this evaluation, a reclassification status of interim closed out has been determined. The results demonstrate that the site will support future unrestricted land uses that can be represented by a rural-residential scenario. These results also show that residual concentrations support unrestrictedmore » future use of shallow zone soil and that contaminant levels remaining in the soil are protective of groundwater and the Columbia River.« less

  20. Field study comparing the effect of hydraulic mixing on septic tank performance and sludge accumulation.

    PubMed

    Almomani, Fares

    2016-01-01

    This study investigates the effect of hydraulic mixing on anaerobic digestion and sludge accumulation in a septic tank. The performance of a septic tank equipped with a hydraulic mixer was compared with that of a similar standard septic tank over a period of 10 months. The study was conducted in two phases: Phase-I--from May to November 2013 (6 months); Phase-II--from January to May 2014 (4 months). Hydraulic mixing effectively reduced the effluent biological oxygen demand (BOD) and total suspended solids, and reduced the sludge accumulation rate in the septic tank. The BOD removal efficiencies during Phase-II were 65% and 75% in the standard septic tank and a septic tank equipped with hydraulic mixer (Smart Digester™), respectively. The effect of hydraulic mixing reduced the rate of sludge accumulation from 0.64 cm/day to 0.27 cm/day, and increased the pump-out interval by a factor of 3.

  1. HYDRAULICS AND MIXING EVALUATIONS FOR NT-21/41 TANKS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, S.; Barnes, O.

    2014-11-17

    The hydraulic results demonstrate that pump head pressure of 20 psi recirculates about 5.6 liters/min flowrate through the existing 0.131-inch orifice when a valve connected to NT-41 is closed. In case of the valve open to NT-41, the solution flowrates to HB-Line tanks, NT-21 and NT-41, are found to be about 0.5 lpm and 5.2 lpm, respectively. The modeling calculations for the mixing operations of miscible fluids contained in the HB-Line tank NT-21 were performed by taking a three-dimensional Computational Fluid Dynamics (CFD) approach. The CFD modeling results were benchmarked against the literature results and the previous SRNL test resultsmore » to validate the model. Final performance calculations were performed for the nominal case by using the validated model to quantify the mixing time for the HB-Line tank. The results demonstrate that when a pump recirculates a solution volume of 5.7 liters every minute out of the 72-liter tank contents containing two acid solutions of 2.7 M and 0 M concentrations (i.e., water), a minimum mixing time of 1.5 hours is adequate for the tank contents to get the tank contents adequately mixed. In addition, the sensitivity results for the tank contents of 8 M existing solution and 1.5 M incoming species show that the mixing time takes about 2 hours to get the solutions mixed.« less

  2. General practitioners' satisfaction with and attitudes to out-of-hours services.

    PubMed

    van Uden, Caro J T; Nieman, Fred H M; Voss, Gemma B W E; Wesseling, Geertjan; Winkens, Ron A G; Crebolder, Harry F J M

    2005-03-31

    In recent years, Dutch general practitioner (GP) out-of-hours service has been reorganised into large-scale GP cooperatives. Until now little is known about GPs' experiences with working at these cooperatives for out-of-hours care. The purpose of this study is to gain insight into GPs' satisfaction with working at GP cooperatives for out-of-hours care in separated and integrated cooperatives. A GP cooperative separate from the hospital Accident and Emergency (A&E) department, and a GP cooperative integrated within the A&E department of another hospital. Both cooperatives are situated in adjacent geographic regions in the South of The Netherlands. One hundred GPs were interviewed by telephone; fifty GPs working at the separated GP cooperative and fifty GPs from the integrated GP cooperative. Opinions on different aspects of GP cooperatives for out-of-hours care were measured, and regression analysis was performed to investigate if these could be related to GP satisfaction with out-of-hours care organisation. GPs from the separated model were more satisfied with the organisation of out-of-hours care than GPs from the integrated model (70 vs. 60 on a scale score from 0 to 100; P = 0.020). Satisfaction about out-of-hours care organisation was related to opinions on workload, guarantee of gatekeeper function, and attitude towards out-of-hours care as being an essential part of general practice. Cooperation with medical specialists was much more appreciated at the integrated model (77 vs. 48; P < 0.001) versus the separated model. GPs in this study appear to be generally satisfied with the organisation of GP cooperatives for out-of-hours care. Furthermore, GPs working at the separated cooperative seem to be more satisfied compared to GPs working at the integrated cooperative.

  3. Effect of tank diameter on thermal behavior of gasoline and diesel storage tanks fires.

    PubMed

    Leite, Ricardo Machado; Centeno, Felipe Roman

    2018-01-15

    Studies on fire behavior are extremely important as they contribute in a firefighting situation or even to avoid such hazard. Experimental studies of fire in real scale are unfeasible, implying that reduced-scale experiments must be performed, and results extrapolated to the range of interest. This research aims to experimentally study the fire behavior in tanks of 0.04m, 0.20m, 0.40m, 0.80m and 4.28m diameter, burning regular gasoline or diesel oil S-500. The following parameters were here obtained: burning rates, burning velocities, heat release rates, flame heights, and temperature distributions adjacent to the tank. Such parameters were obtained for each tank diameter with the purpose of correlating the results and understanding the relationship of each parameter for the different geometrical scale of the tanks. Asymptotic results for larger tanks were found as (regular gasoline and diesel oil S-500, respectively): burning rates 0.050kg/(m 2 s) and 0.031kg/(m 2 s), burning velocities 4.0mm/min and 2.5mm/min, heat release rates per unit area 2200kW/m 2 and 1500kW/m 2 , normalized averaged flame heights (H i /D, where H i is the average flame height, D is the tank diameter) 0.9 and 0.8. Maximum temperatures for gasoline pools were higher than for diesel oil pools, and temperature gradients close to the tanks were also higher for the former fuel. The behavior of the maximum temperature was correlated as a function of the tank diameter, the heat release rate of each fuel and the dimensionless distance from the tank. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. VIEW OF PDP TANK TOP, LEVEL 0’, WITH LTR TANK ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF PDP TANK TOP, LEVEL 0’, WITH LTR TANK TOP ON LEFT, LOOKING NORTHEAST. CRANE AND VERTICAL HOISTING ELEMENTS AT TOP - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  5. 46 CFR 32.65-30 - Tank vessels with independent tanks-TB/ALL.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Tank vessels with independent tanks-TB/ALL. 32.65-30 Section 32.65-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Hull Requirements for Tank Vessels Constructed On or After November 10...

  6. 46 CFR 32.65-30 - Tank vessels with independent tanks-TB/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Tank vessels with independent tanks-TB/ALL. 32.65-30 Section 32.65-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Hull Requirements for Tank Vessels Constructed On or After November 10...

  7. 46 CFR 32.65-30 - Tank vessels with independent tanks-TB/ALL.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false Tank vessels with independent tanks-TB/ALL. 32.65-30 Section 32.65-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Hull Requirements for Tank Vessels Constructed On or After November 10...

  8. 46 CFR 32.65-30 - Tank vessels with independent tanks-TB/ALL.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Tank vessels with independent tanks-TB/ALL. 32.65-30 Section 32.65-30 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Hull Requirements for Tank Vessels Constructed On or After November 10...

  9. The effectiveness of contracting-out primary health care services in developing countries: a review of the evidence.

    PubMed

    Liu, Xingzhu; Hotchkiss, David R; Bose, Sujata

    2008-01-01

    The purpose of this study is to review the research literature on the effectiveness of contracting-out of primary health care services and its impact on both programme and health systems performance in low- and middle-income countries. Due to the heightened interest in improving accountability relationships in the health sector and in rapidly scaling up priority interventions, there is an increasing amount of interest in and experimentation with contracting-out. Overall, while the review of the selected studies suggests that contracting-out has in many cases improved access to services, the effects on other performance dimensions such as equity, quality and efficiency are often unknown. Moreover, little is known about the system-wide effects of contracting-out, which could be either positive or negative. Although the study results leave open the question of how contracting-out can be used as a policy tool to improve overall health system performance, the results indicate that the context in which contracting-out is implemented and the design features of the interventions are likely to greatly influence the chances for success.

  10. Addendum to the Streamlined Approach for Environmental Restoration Closure Report for Corrective Action Unit 452: Historical Underground Storage Tank Release Sites, Nevada Test Site, Nevada, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grant Evenson

    This document constitutes an addendum to the Streamlined Approach for Environmental Restoration Closure Report for Corrective Action Unit 452: Historical Underground Storage Tank Release Sites, Nevada Test Site, Nevada, April 1998 as described in the document Supplemental Investigation Report for FFACO Use Restrictions, Nevada Test Site, Nevada (SIR) dated November 2008. The SIR document was approved by NDEP on December 5, 2008. The approval of the SIR document constituted approval of each of the recommended UR removals. In conformance with the SIR document, this addendum consists of: • This page that refers the reader to the SIR document for additionalmore » information • The cover, title, and signature pages of the SIR document • The NDEP approval letter • The corresponding section of the SIR document This addendum provides the documentation justifying the cancellation of the URs for CASs: • 25-25-09, Spill H940825C (from UST 25-3101-1) • 25-25-14, Spill H940314E (from UST 25-3102-3) • 25-25-15, Spill H941020E (from UST 25-3152-1) These URs were established as part of Federal Facility Agreement and Consent Order (FFACO) corrective actions and were based on the presence of contaminants at concentrations greater than the action levels established at the time of the initial investigation (FFACO, 1996). Since these URs were established, practices and procedures relating to the implementation of risk-based corrective actions (RBCA) have changed. Therefore, these URs were re-evaluated against the current RBCA criteria as defined in the Industrial Sites Project Establishment of Final Action Levels (NNSA/NSO, 2006). This re-evaluation consisted of comparing the original data (used to define the need for the URs) to risk-based final action levels (FALs) developed using the current Industrial Sites RBCA process. The re-evaluation resulted in a recommendation to remove these URs because contamination is not present at these sites above the risk-based FALs

  11. 49 CFR 179.220 - General specifications applicable to nonpressure tank car tanks consisting of an inner container...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... tank car tanks consisting of an inner container supported within an outer shell (class DOT-115). 179... AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Non-Pressure Tank Car Tanks (Classes DOT-111AW and 115AW) § 179.220...

  12. Developments in the safe design of LNG tanks

    NASA Astrophysics Data System (ADS)

    Fulford, N. J.; Slatter, M. D.

    The objective of this paper is to discuss how the gradual development of design concepts for liquefied natural gas (LNG) storage systems has helped to enhance storage safety and economy. The experience in the UK is compared with practice in other countries with similar LNG storage requirements. Emphasis is placed on the excellent record of safety and reliability exhibited by tanks with a primary metal container designed and constructed to approved standards. The work carried out to promote the development of new materials, fire protection, and monitoring systems for use in LNG storage is also summarized, and specific examples described from British Gas experience. Finally, the trends in storage tank design world-wide and options for future design concepts are discussed, bearing in mind planned legislation and design codes governing hazardous installations.

  13. Photogrammetry Measurements During a Tanking Test on the Space Shuttle External Tank, ET-137

    NASA Technical Reports Server (NTRS)

    Littell, Justin D.; Schmidt, Tim; Tyson, John; Oliver, Stanley T.; Melis, Matthew E.; Ruggeri, Charles

    2012-01-01

    On November 5, 2010, a significant foam liberation threat was observed as the Space Shuttle STS-133 launch effort was scrubbed because of a hydrogen leak at the ground umbilical carrier plate. Further investigation revealed the presence of multiple cracks at the tops of stringers in the intertank region of the Space Shuttle External Tank. As part of an instrumented tanking test conducted on December 17, 2010, a three dimensional digital image correlation photogrammetry system was used to measure radial deflections and overall deformations of a section of the intertank region. This paper will describe the experimental challenges that were overcome in order to implement the photogrammetry measurements for the tanking test in support of STS-133. The technique consisted of configuring and installing two pairs of custom stereo camera bars containing calibrated cameras on the 215-ft level of the fixed service structure of Launch Pad 39-A. The cameras were remotely operated from the Launch Control Center 3.5 miles away during the 8 hour duration test, which began before sunrise and lasted through sunset. The complete deformation time history was successfully computed from the acquired images and would prove to play a crucial role in the computer modeling validation efforts supporting the successful completion of the root cause analysis of the cracked stringer problem by the Space Shuttle Program. The resulting data generated included full field fringe plots, data extraction time history analysis, section line spatial analyses and differential stringer peak ]valley motion. Some of the sample results are included with discussion. The resulting data showed that new stringer crack formation did not occur for the panel examined, and that large amounts of displacement in the external tank occurred because of the loads derived from its filling. The measurements acquired were also used to validate computer modeling efforts completed by NASA Marshall Space Flight Center (MSFC).

  14. TEST STAND 4697 CONSTRUCTION TOP OUT

    NASA Image and Video Library

    2016-03-04

    ON MARCH 4, CREW MEMBERS READIED A 900-POUND STEEL BEAM TO "TOP OUT" TEST STAND 4697, WHICH IS UNDER CONSTRUCTION TO TEST THE SPACE LAUNCH SYSTEM LIQUID OXYGEN TANK AT NASA'S MARSHALL SPACE FLIGHT CENTER.

  15. 49 CFR 179.201 - Individual specification requirements applicable to non-pressure tank car tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... to non-pressure tank car tanks. 179.201 Section 179.201 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Non-Pressure Tank Car Tanks (Classes DOT-111AW...

  16. Tank characterization report for double-shell tank 241-AW-105

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sasaki, L.M.

    1997-06-05

    One of the major functions of the Tank Waste Remediation System (TWRS) is to characterize wastes in support of waste management and disposal activities at the Hanford Site. Analytical data from sampling and analysis, along with other available information about a tank, are compiled and maintained in a tank characterization report (TCR). This report and its appendices serve as the TCR for double-shell tank 241-AW-105. The objectives of this report are to use characterization data in response to technical issues associated with tank 241-AW-105 waste; and to provide a standard characterization of this waste in terms of a best-basis inventorymore » estimate. The response to technical issues is summarized in Section 2.0, and the best-basis inventory estimate is presented in Section 3.0. Recommendations regarding safety status and additional sampling needs are provided in Section 4.0. Supporting data and information are contained in the appendices. This report supports the requirements of the Hanford Federal Facility Agreement and Consent Order milestone Characterization. information presented in this report originated from sample analyses and known historical sources. While only the results of a recent sampling event will be used to fulfill the requirements of the data quality objectives (DQOs), other information can be used to support or question conclusions derived from these results. Historical information for tank 241-AW-105 is provided in Appendix A, including surveillance information, records pertaining to waste transfers and tank operations, and expected tank contents derived from a process knowledge model. The recent sampling event listed, as well as pertinent sample data obtained before 1996, are summarized in Appendix B along with the sampling results. The results of the 1996 grab sampling event satisfied the data requirements specified in the sampling and analysis plan (SAP) for this tank. In addition, the tank headspace flammability was measured, which

  17. Antibiotic prescribing for acute respiratory tract infections in Norwegian primary care out-of-hours service

    PubMed Central

    Lindberg, Bent H.; Gjelstad, Svein; Foshaug, Mats; Høye, Sigurd

    2017-01-01

    Purpose To examine factors correlating with antibiotic prescribing for acute respiratory tract infections (ARTIs) in Norwegian primary care out-of-hours service. Materials and methods Retrospective data analysis for the year 2014 in two out-of-hours primary care units located in the towns of Hamar and Tønsberg in Norway, analysing type and frequency of different antibiotics prescribed by 117 medical doctors for ARTIs, and factors correlating with these. Results The 117 doctors in two out-of-hours units diagnosed 6757 cases of ARTIs. 2310 (34.2%) of these resulted in an antibiotic prescription, where of 1615 (69.9%) were penicillin V (PcV). Tonsillitis and sinusitis were the two ARTI diagnoses with the highest antibiotic prescription rate. The antibiotic prescription rate increased successively with increasing activity level, measured as shorter median duration of consultations per session, from 28.7% (reference) in the least busy quintile of sessions to 36.6% (OR: 1.38 (95% CI =1.06–1.80)) in the busiest quintile of sessions. Prescribing of broad-spectrum antibiotics was not correlated with median duration of consultations per session. Female doctors had an OR of 0.61 (0.40–0.92) of a broad-spectrum antibiotic prescription compared to their male colleagues. Conclusions Antibiotic prescribing for ARTIs in the primary care out-of-hours services investigated is at the same level as in Norwegian general practice, but with a higher prescription rate of PcV. Antibiotic prescribing increases on busy sessions, measured as median duration of consultations per session. The work frame in primary care out-of-hours service might influence the quality of clinical decisions. PMID:28569649

  18. Factors associated with emergency services use in Taiwanese advanced cancer patients receiving palliative home care services during out-of-hours periods: a retrospective medical record study.

    PubMed

    Kao, Yee-Hsin; Liu, Yao-Ting; Koo, Malcolm; Chiang, Jui-Kun

    2018-03-12

    For patients receiving palliative home care, the need to visit the emergency department is considered to be an indicator of poor quality care. The situation can be particularly distressing when it occurs outside of normal hours of palliative home care service. The aim of this study was to investigate the factors for emergency department use during out-of-hours periods of palliative home care service among advanced cancer patients in Taiwan. This case-control study was based on a retrospective medical chart review (January 2010 to December 2012) of advanced cancer patients who were receiving palliative home care in a community hospital in south Taiwan. The use of emergency medical services by these patients was dichotomized into either normal hours (8 a.m. to midnight, Monday to Friday, excluding public holidays) of palliative home care or outside normal hours. Logistic regression analyses were performed to evaluate factors associated with emergency services use during out-of-hours period of palliative home care. Of the 94 patients receiving palliative home care, 65 had used emergency services at least once during the 3-year study period. Of these 65 patients, 40% used emergency services during out-of-hours of palliative home care. Patients with distressing conditions (defined as the occurrence of any two conditions of dyspnea, change of consciousness, or gastrointestinal bleeding) were significantly more likely to use emergency services during out-of-hours of palliative home care. Patients at risk of developing dyspnea, change of consciousness, or gastrointestinal bleeding should be provided with relevant information regarding these symptoms and signs.

  19. Providing health services for children with special health care needs on out-of-state field trips.

    PubMed

    Erwin, Karen; Clark, Saudi; Mercer, Sharon Eli

    2014-03-01

    An increasing number of children attend school with special health care needs. Title II of the Americans with Disabilities Act (ADA) requires all school-sponsored activities to be easily accessible to all students. School-sponsored field trips enhance students' education, and students who require health services may not be excluded. For students with special health care needs, fully participating in the field trip experience presents unique challenges. These challenges are further complicated by out-of-state field trips due to variances in nurse practice acts, variances in delegation regulations, and most recently, state-by-state participation or nonparticipation in the Nurse Licensure Compact. Review of state laws, regulations, and nursing scope of practice for school health services is critical when planning and problem solving for students requiring health services on out-of-state field trips.

  20. 17 CFR 160.14 - Exceptions to notice and opt out requirements for processing and servicing transactions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... or authorizes, or in connection with: (1) Processing or servicing a financial product or service that... persons engaged in carrying out the financial transaction or providing the product or service; or (2...'s account in the ordinary course of providing the financial service or financial product; (ii) To...

  1. Assessment of Tank 241-S-112 Liquid Waste Mixing in Tank 241-SY-101

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Onishi, Yasuo; Trent, Donald S.; Wells, Beric E.

    The objectives of this study were to evaluate mixing of liquid waste from Tank 241-S-112 with waste in Tank 241-SY-101 and to determine the properties of the resulting waste for the cross-site transfer to avoid potential double-shell tank corrosion and pipeline plugging. We applied the time-varying, three-dimensional computer code TEMPEST to Tank SY-101 as it received the S-112 liquid waste. The model predicts that temperature variations in Tank SY-101 generate a natural convection flow that is very slow, varying from about 7 x 10{sup -5} to 1 x 10{sup -3} ft/sec (0.3 to about 4 ft/hr) in most areas. Thus,more » natural convection would eventually mix the liquid waste in SY-101 but would be very slow to achieve nearly complete mixing. These simulations indicate that the mixing of S-112 and SY-101 wastes in Tank SY-101 is a very slow process, and the density difference between the two wastes would further limit mixing. It is expected to take days or weeks to achieve relatively complete mixing in Tank SY-101.« less

  2. Use of avoidance response by rainbow trout to carbon dioxide for fish self-transfer between tanks

    USGS Publications Warehouse

    Clingerman, J.; Bebak, J.; Mazik, P.M.; Summerfelt, S.T.

    2007-01-01

    Convenient, economical, and reduced labor fish harvest and transfer systems are required to realize operating cost savings that can be achieved with the use of much larger and deeper circular culture tanks. To achieve these goals, we developed a new technology for transferring fish based on their avoidance behavior to elevated concentrations of dissolved carbon dioxide (CO2). We observed this behavioral response during controlled, replicated experiments that showed dissolved CO2 concentrations of 60-120 mg/L induced rainbow trout (Oncorhynchus mykiss) to swim out of their 11 m3 "growout" tank, through a transfer pipe carrying a flow with ???23 mg/L dissolved CO2, into a second 11 m3 "harvest" tank. The research was conducted using separate groups of rainbow trout held at commercially relevant densities (40-60 kg/m3). The average weight of fish ranged from 0.15 to 1.3 kg during the various trials. In all trials that used a constant flow of low CO2 water (???23 mg/L) entering the growout tank from the harvest tank, approximately 80-90% of the fish swam from the growout tank, through the transfer pipe, and into the harvest tank after the CO2 concentration in the growout tank had exceeded 60 mg/L. The fish that remained in the growout tank stayed within the area of relatively low CO2 water at the entrance of the transfer pipe. However, the rate of fish transfer from the growout tank to the harvest tank was more than doubled when the diameter of the transfer pipe was increased from 203 to 406 mm. To consistently achieve fish transfer efficiencies of 99%, water flow rate through the fish transfer pipe had to be reduced to 10-20% of the original flow just before the conclusion of each trial. Reducing the flow of relatively low CO2 water near the end of each fish transfer event, restricted the zone of relatively low CO2 water about the entrance of the fish transfer pipe, and provided the stimulus for all but a few remaining fish to swim out of the growout tank. Results

  3. The association of persistent pain with out-patient addiction treatment outcomes and service utilization.

    PubMed

    Caldeiro, Ryan M; Malte, Carol A; Calsyn, Donald A; Baer, John S; Nichol, Paul; Kivlahan, Daniel R; Saxon, Andrew J

    2008-12-01

    To estimate the prevalence of persistent pain among veterans in out-patient addiction treatment and examine associated addiction treatment outcomes and medical and psychiatric service use. Analysis of data from a prospective randomized controlled trial comparing on-site versus referral primary care of veterans with substance dependence (n = 582), excluding opioid dependence who had at least one follow-up interview during the 12-month study period in a Veterans Affairs (VA) out-patient addiction treatment center. Pain status was classified as persistent (pain was rated moderate to very severe at all time-points), low (pain was rated none to mild at all time-points) or intermittent (all others). Main outcome measures were addiction treatment retention, addiction severity index (ASI) alcohol and drug composite scores, VA service utilization and treatment costs. A total of 33.2% of veterans reported persistent pain and 47.3% reported intermittent pain. All groups benefited from addiction treatment, but veterans with persistent pain were in treatment for an estimated 35.1 fewer days [95% confidence interval (CI) = -64.1, -6.1, P = 0.018], less likely to be abstinent from alcohol or drugs at 12 months [odds ratio (OR)(adj) = 0.52; 95% CI = 0.30,0.89; P = 0.018], had worse ASI alcohol composite scores at 12 months (beta(adj) = 0.09; 95% CI = 0.02,0.15; P = 0.007), were more likely to be medically hospitalized (OR(adj) = 2.70; 95% CI = 1.02,7.13; P = 0.046) and had higher total service costs compared to those with low pain ($17 766 versus $13 261, P = 0.012). Persistent pain is common among veterans in out-patient addiction treatment and is associated with poorer rates of abstinence, worse alcohol use severity and greater service utilization and costs than those with low pain.

  4. Improving the food provided and food safety practices in out-of-school-hours services.

    PubMed

    Cooke, Lara; Sangster, Janice; Eccleston, Philippa

    2007-04-01

    Food provided and food safety and serving practices in out-of-school-hours (OOSH) services. Health promotion strategies, developed in partnership with an advisory committee, were directed at three main areas: supporting local services; developing statewide training and resources; and advocacy. Significant improvements were seen in the food provided, food safety and serving practices and the number of services with planned menus and nutrition and food safety policies. This project is one of the first implemented and evaluated in the OOSH setting. Statistically significant improvements were achieved in the food provided, food safety and serving practices, and menu and policy development. The project also increased the capacity of the OOSH sector to improve children's health by making suitable nutrition and food safety resources and training available to OOSH services across New South Wales.

  5. Is a Turretless Tank a Viable Option for the United States Army

    DTIC Science & Technology

    1990-06-01

    The available pool of service age manpower will decline. The societal trend to smaller, later families and the demographics of the post baby boom...current age of U.S tank devel- opment, began in 1963 and continues to the present. It began with an abortive attempt to jointly design a tank with...Intensity Conflict: The U. S. Expierence ," Armor. The Magazine of Mobile Warfare, XCVII (July-August 1988): 9-15. Nitkowski, Steven R. ILT. "The Return

  6. Decay resistance of out-of-service utility poles as related to the distribution of residual creosote content

    Treesearch

    Han Roliadi; Chung Y. Hse; Elvin T. Choong; Todd F. Shupe

    2000-01-01

    Decay resistance of out-of-service poles was investigated to evaluate their effectiveness against biodegradation for possible recycling of these poles for composite products. Decay resistance was related to creosote content and creosote distribution in poles with service durations of 5 and 25 years and also freshly treated poles. Weathering of the poles had caused...

  7. Defect Characterization in a Thin Walled Composite RP-1 Tank: A Case Study

    NASA Technical Reports Server (NTRS)

    Langsing, Matthew D.; Walker, James L., II; Russell, Samual S.

    2000-01-01

    A full scale thin walled composite tank, designed and fabricated for the storage of pressurized RP- I rocket fuel, was fully inspected with digital infrared thermography (IR) during assembly and prior to proof testing. The tank featured a "pill capsule" design with the equatorial bondline being overwrapped on both the inner and outer surfaces. A composite skirt was bonded to the aft dome of the tank to serve as a structural support when the tank was stood on end in service. Numerous anomalies were detected and mapped prior to proof testing, some along bondlines and some scattered throughout the acreage. After the tank was intentionally burst, coupons were cut from the regions including thermographic anomalies. These coupons were again inspected thermographically to document the growth of any indications due to proof testing. Ultrasonic inspections (UT) were also performed on the coupons for comparison to thermography. Several coupons were dissected and micrographed. Relationships between IR and UT indications and the physical nature of the dissected material are presented.

  8. 49 CFR 179.103 - Special requirements for class 114A * * * tank car tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Special requirements for class 114A * * * tank car...) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120...

  9. Branching Out in Youth Services.

    ERIC Educational Resources Information Center

    Iffland, Carol D., Ed.

    1985-01-01

    These articles provide testimony in support of youth services which have been and continue to be a vital part of public library service in Illinois. Organized around the symbol of a mighty oak tree, the articles are divided into three sections: (1) The Trunk--based on strong roots with the past, standards, goals, and objectives are formulated; (2)…

  10. Study of Vapour Cloud Explosion Impact from Pressure Changes in the Liquefied Petroleum Gas Sphere Tank Storage Leakage

    NASA Astrophysics Data System (ADS)

    Rashid, Z. A.; Suhaimi Yeong, A. F. Mohd; Alias, A. B.; Ahmad, M. A.; AbdulBari Ali, S.

    2018-05-01

    This research was carried out to determine the risk impact of Liquefied Petroleum Gas (LPG) storage facilities, especially in the event of LPG tank explosion. In order to prevent the LPG tank explosion from occurring, it is important to decide the most suitable operating condition for the LPG tank itself, as the explosion of LPG tank could affect and cause extensive damage to the surrounding. The explosion of LPG tank usually occurs due to the rise of pressure in the tank. Thus, in this research, a method called Planas-Cuchi was applied to determine the Peak Side-On Overpressure (Po) of the LPG tank during the occurrence of explosion. Thermodynamic properties of saturated propane, (C3H8) have been chosen as a reference and basis of calculation to determine the parameters such as Explosion Energy (E), Equivalent Mass of TNT (WTNT), and Scaled Overpressure (PS ). A cylindrical LPG tank in Feyzin Refinery, France was selected as a case study in this research and at the end of this research, the most suitable operating pressure of the LPG tank was determined.

  11. Provider cost analysis supports results-based contracting out of maternal and newborn health services: an evidence-based policy perspective.

    PubMed

    Hatcher, Peter; Shaikh, Shiraz; Fazli, Hassan; Zaidi, Shehla; Riaz, Atif

    2014-11-13

    There is dearth of evidence on provider cost of contracted out services particularly for Maternal and Newborn Health (MNH). The evidence base is weak for policy makers to estimate resources required for scaling up contracting. This paper ascertains provider unit costs and expenditure distribution at contracted out government primary health centers to inform the development of optimal resource envelopes for contracting out MNH services. This is a case study of provider costs of MNH services at two government Rural Health Centers (RHCs) contracted out to a non-governmental organization in Pakistan. It reports on four selected Basic Emergency Obstetrical and Newborn Care (BEmONC) services provided in one RHC and six Comprehensive Emergency Obstetrical and Newborn Care (CEmONC) services in the other. Data were collected using staff interviews and record review to compile resource inputs and service volumes, and analyzed using the CORE Plus tool. Unit costs are based on actual costs of MNH services and are calculated for actual volumes in 2011 and for volumes projected to meet need with optimal resource inputs. The unit costs per service for actual 2011 volumes at the BEmONC RHC were antenatal care (ANC) visit USD$ 18.78, normal delivery US$ 84.61, newborn care US$ 16.86 and a postnatal care (PNC) visit US$ 13.86; and at the CEmONC RHC were ANC visit US$ 45.50, Normal Delivery US$ 148.43, assisted delivery US$ 167.43, C-section US$ 183.34, Newborn Care US$ 41.07, and PNC visit US$ 27.34. The unit costs for the projected volumes needed were lower due to optimal utilization of resources. The percentage distribution of expenditures at both RHCs was largest for salaries of technical staff, followed by salaries of administrative staff, and then operating costs, medicines, medical and diagnostic supplies. The unit costs of MNH services at the two contracted out government rural facilities remain higher than is optimal, primarily due to underutilization. Provider cost analysis

  12. SLUDGE RETRIEVAL FROM HANFORD K WEST BASIN SETTLER TANKS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ERPENBECK EG; LESHIKAR GA

    In 2010, an innovative, remotely operated retrieval system was deployed to successfully retrieve over 99.7% of the radioactive sludge from ten submerged tanks in Hanford's K-West Basin. As part of K-West Basin cleanup, the accumulated sludge needed to be removed from the 0.5 meter diameter by 5 meter long settler tanks and transferred approximately 45 meters to an underwater container for sampling and waste treatment. The abrasive, dense, non-homogeneous sludge was the product of the washing process of corroded nuclear fuel. It consists of small (less than 600 micron) particles of uranium metal, uranium oxide, and various other constituents, potentiallymore » agglomerated or cohesive after 10 years of storage. The Settler Tank Retrieval System (STRS) was developed to access, mobilize and pump out the sludge from each tank using a standardized process of retrieval head insertion, periodic high pressure water spray, retraction, and continuous pumping of the sludge. Blind operations were guided by monitoring flow rate, radiation levels in the sludge stream, and solids concentration. The technology developed and employed in the STRS can potentially be adapted to similar problematic waste tanks or pipes that must be remotely accessed to achieve mobilization and retrieval of the sludge within.« less

  13. Preliminary remedial action objectives for the Tank 16 groundwater operable unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miles, W.C. Jr.

    1992-10-28

    Tank 16 is a High Level Radioactive Waste tank in the H-Area Tank Farm on the Savannah River Site that was placed into service in May 1959. A leak was detected in one of the construction weld joints while the tank was being filled. Before jet evacuation of the tank waste was completed, the leak overflowed the annulus pan and an estimated 16 to 700 gallons of waste escaped to the environment (soil and groundwater) over a six hour period contaminating approximately 1,600--70,000 cubic feet of soil with up to 5000 curies of activity (principally Cs[sup 137]). The Tank 16more » bottom is constructed below the groundwater table which resulted in almost immediate contamination of that medium. Low groundwater flow rates, the ion exchange property of adjacent soils, and the distance to the nearest surface water bodies (1,500 to 8,000 feet) indicates that surface water and sediment outcrop of contaminates may be expected between 44 and 530 years (Poe et al., 1974). Remedial action objectives consist of medium-specific and operable unit specific goals for protecting human health and the environment. These objectives are specific and do not limit the range of alternatives that may be developed.A range of remedial technologies, which provides for treatment, containment, and removal requirements of contaminated media remaining at the Tank 16 groundwater operable unit, is identified and developed for each general response action.« less

  14. Preliminary remedial action objectives for the Tank 16 groundwater operable unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miles, W.C. Jr.

    1992-10-28

    Tank 16 is a High Level Radioactive Waste tank in the H-Area Tank Farm on the Savannah River Site that was placed into service in May 1959. A leak was detected in one of the construction weld joints while the tank was being filled. Before jet evacuation of the tank waste was completed, the leak overflowed the annulus pan and an estimated 16 to 700 gallons of waste escaped to the environment (soil and groundwater) over a six hour period contaminating approximately 1,600--70,000 cubic feet of soil with up to 5000 curies of activity (principally Cs{sup 137}). The Tank 16more » bottom is constructed below the groundwater table which resulted in almost immediate contamination of that medium. Low groundwater flow rates, the ion exchange property of adjacent soils, and the distance to the nearest surface water bodies (1,500 to 8,000 feet) indicates that surface water and sediment outcrop of contaminates may be expected between 44 and 530 years (Poe et al., 1974). Remedial action objectives consist of medium-specific and operable unit specific goals for protecting human health and the environment. These objectives are specific and do not limit the range of alternatives that may be developed.A range of remedial technologies, which provides for treatment, containment, and removal requirements of contaminated media remaining at the Tank 16 groundwater operable unit, is identified and developed for each general response action.« less

  15. System Description for Tank 241-AZ-101 Waste Retrieval Data Acquisition System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ROMERO, S.G.

    2000-02-14

    The proposed activity provides the description of the Data Acquisition System for Tank 241-AZ-101. This description is documented in HNF-5572, Tank 241-AZ-101 Waste Retrieval Data Acquisition System (DAS). This activity supports the planned mixer pump tests for Tank 241-AZ-101. Tank 241-AZ-101 has been selected for the first full-scale demonstration of a mixer pump system. The tank currently holds over 960,000 gallons of neutralized current acid waste, including approximately 12.7 inches of settling solids (sludge) at the bottom of the tank. As described in Addendum 4 of the FSAR (LMHC 2000a), two 300 HP mixer pumps with associated measurement and monitoringmore » equipment have been installed in Tank 241-AZ-101. The purpose of the Tank 241-AZ-101 retrieval system Data Acquisition System (DAS) is to provide monitoring and data acquisition of key parameters in order to confirm the effectiveness of the mixer pumps utilized for suspending solids in the tank. The suspension of solids in Tank 241-AZ-101 is necessary for pretreatment of the neutralized current acid waste and eventual disposal as glass via the Hanford Waste Vitrification Plant. HNF-5572 provides a basic description of the Tank 241-AZ-101 retrieval system DAS, including the field instrumentation and application software. The DAS is provided to fulfill requirements for data collection and monitoring. This document is not an operations procedure or is it intended to describe the mixing operation. This USQ screening provides evaluation of HNF-5572 (Revision 1) including the changes as documented on ECN 654001. The changes include (1) add information on historical trending and data backup, (2) modify DAS I/O list in Appendix E to reflect actual conditions in the field, and (3) delete IP address in Appendix F per Lockheed Martin Services, Inc. request.« less

  16. The impact of contracting out on health outcomes and use of health services in low and middle-income countries.

    PubMed

    Lagarde, Mylene; Palmer, Natasha

    2009-10-07

    Recent literature on the lack of efficiency and acceptability of publicly provided health services has led to an interest in the use of partnerships with the private sector to deliver public services. To assess the effectiveness of contracting out healthcare services in improving access to care in low and middle-income countries and, where possible, health outcomes. We searched a wide range of international databases, including the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE and EMBASE, in addition to development studies and economic databases. We also searched the websites and online resources of numerous international agencies, organisations and universities to find relevant grey literature. The original searches were conducted between November 2005 and April 2006. An updated search in MEDLINE was carried out in May 2009. Contracting out health services is defined as the provision of healthcare services on behalf of the government by non-state providers. Studies had to include an objective measure of at least one of the following outcomes: health care utilisation, health expenditure, health outcomes or equity outcomes. Studies also needed to use one of the following study designs: randomised controlled trial, non-randomised controlled trial, interrupted time series analysis or controlled before and after study. We made an attempt to present results from the different studies in a systematic way, however due to the diversity of sources, contexts and methods used, we undertook a narrative synthesis. Three studies met our inclusion criteria (one after re-analysis of data). These studies suggest that contracting out services to non-state providers can increase access and utilisation of health services. One study found a reduction in out-of-pocket expenditures and improvement in some health outcomes. However, methodological weaknesses and particularities of the reported programme settings limit the strength and generalisability of their

  17. Tank characterization report for single-shell tank 241-C-109

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simpson, B.C.

    1997-05-23

    One of the major functions of the Tank Waste Remediation System (TWRS) is to characterize wastes in support of waste management and disposal activities at the Hanford Site. Analytical data from sampling and analysis, along with other available information about a tank, are compiled and maintained in a tank characterization report (TCR). This report and its appendices serve as the TCR for single-shell tank 241-C-109. The objectives of this report are: (1) to use characterization data in response to technical issues associated with tank 241 C-109 waste; and (2) to provide a standard characterization of this waste in terms ofmore » a best-basis inventory estimate. The response to technical issues is summarized in Section 2.0, and the best-basis inventory estimate is presented in Section 3.0. Recommendations regarding safety status and additional sampling needs are provided in Section 4.0. Supporting data and information are contained in the appendices.« less

  18. Contracting out of clinical services in Zimbabwe.

    PubMed

    McPake, B; Hongoro, C

    1995-07-01

    Contracting is increasingly recommended to developing countries as a way of improving the efficiency of the health sector. However, empirical evidence regarding its effectiveness in this respect is almost completely absent. In Zimbabwe, a long standing contract exists between the Ministry of Health and Wankie Colliery to provide clinical services in the Colliery's 400 bed hospital. This paper details a study of the Zimbabweans' experience with the contract. Its success is assessed using comparisons with a neighbouring government hospital of the price of services (vs the cost in the government hospital); the situation of hospital workers; and the quality of services delivered. The Colliery has established a monopoly position for hospital services in the district. However, it appears to offer services of at least as good quality at prices which are lower than the unit costs of the government hospital when capital costs are included. Nevertheless, the contract cannot be considered a success due to the failure to contain its total cost. Approximately 70% of provincial non-salary recurrent expenditure is consumed by the contract while only a minority of the province's population have access to the Colliery hospital. Screening patients, both with respect to their ability to pay and to their need for secondary level services does not take place with the result that utilization levels are not controlled. The study highlights a number of important issues affecting contracting in developing country setting: First, contracted institutions attain powerful bargaining positions if there are no viable competitors and the government does not itself retain capacity to offer an alternative service. Second, specific skills are needed for the management of contracts at all levels. If the process of contract development responds to a crisis driven agenda resulting from civil service retrenchment and public expenditure cuts, it is unlikely that adequate consideration will be given to

  19. 40 CFR 280.20 - Performance standards for new UST systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... protected in the following manner: (i) The tank is coated with a suitable dielectric material; (ii) Field... suitable dielectric material; (ii) Field-installed cathodic protection systems are designed by a corrosion...

  20. 40 CFR 280.20 - Performance standards for new UST systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... protected in the following manner: (i) The tank is coated with a suitable dielectric material; (ii) Field... suitable dielectric material; (ii) Field-installed cathodic protection systems are designed by a corrosion...