Quality comparison of tap water vs. bottled water in the industrial city of Yanbu (Saudi Arabia).
Ahmad, Maqbool; Bajahlan, Ahmad S
2009-12-01
This study was conducted to compare the quality of bottled water with potabilized desalinated tap water. Fourteen brands of local and imported bottled water samples were collected from the local market and analyzed for physicochemical parameters in the Royal Commission Environmental Laboratory. Results were compared with 5-year continuous monitoring data of tap water from different locations in Madinat Yanbu Al-Sinaiyah (MYAS) including storage tanks of desalination plant. Results show that there was no significant difference in the quality of tap water and bottled water. Bacteriological test was never found positive in the 5-year data in tap water. Similarly, physicochemical analysis shows the persistent quality of tap water. Based on hardness analysis, bottled and tap water are categorized as soft water. Trihalomethanes (THMs) study also indicates that traces of disinfection by products (DBPs) are present in both tap and bottled water and are much less than the World Health Organization and Environmental Protection Agency maximum permissible limits. It is also important to note that the tap water distribution network in MAYS is a high-pressure recirculation network and there is no chance to grow bacteria in stagnant water in pipe lines or houses. Recently, the Royal Commission has replaced the whole drinking water network, which was made of asbestos-cemented pipes with glass-reinforced plastic (GRP) pipes, to avoid any asbestos contaminations. Based on these results, it is concluded that drinking water distributed in the city is of very good and persistent quality, comparable with bottled water. Continuous monitoring also guarantees the safe drinking water to the community. Hence, it is the responsibility of the Royal Commission to encourage the peoples in the city to drink tap water as it is as good as bottled water even better than some of the brands and is monitored regularly. It is also much cheaper compared to bottled water and is available round the clock. Preference for tap water over bottled water will also reduce the production of bottled water that has flooded the market, the enormous strain on the environment, and the pollution due to used empty plastic bottles in the landfill area and will help to keep the city clean.
Bharadwaj, Lalita; Waldner, Cheryl L.
2018-01-01
ABSTRACT Previous studies have described concerns regarding tap water in Indigenous communities, yet there is little information on participants who report drinking their tap water and being satisfied with its quality. This study undertaken with members of 8 Indigenous communities in Saskatchewan, Canada, and identified factors associated with both the decision to drink tap water at home and being satisfied with its quality. We examined the importance of factors such as individual attributes, experiences, attitudes, household and community-based variables. Less than one-quarter of participants (23.4%) drank tap water and were satisfied with its quality. Individuals who did not boil tap water (odds ratio [OR] = 5.76, 95% confidence interval [CI] = 1.68–19.8), those who did not experience tap water odour (OR = 2.38, 95% CI = 1.26–4.50) and participants living in communities away from urban centres (OR = 2.74, 95% CI = 1.63–4.51) were more likely to drink and be satisfied with their tap water. Concerns about the environment had the most impact on community members aged 55+ years. Those not reporting concerns about environmental problems affecting water (OR = 11.4, 95% CI = 3.10–42.2) were much more likely to drink and be satisfied with their tap water. Programmes to improve water quality, reduce the need for boil water advisories and increase community confidence in the environment could improve tap water satisfaction and consumption. PMID:29697009
Waldner, Cheryl L; Alimezelli, Hubert Tote; McLeod, Lianne; Zagozewski, Rebecca; Bradford, Lori Ea; Bharadwaj, Lalita A
2017-01-01
Water-related health challenges on First Nations reserves in Canada have been previously documented. Our objective was to describe factors associated with self-reported health effects from tap water in 8 First Nations reserve communities in Saskatchewan, Canada. Community-based participatory approaches were used in designing and implementing cross-sectional household surveys. Individual, household, community, and contextual effects were considered in multilevel analysis. Negative health effects from tap water were reported by 28% of households (n = 579). Concerns about environmental factors affecting water quality (odds ratio [OR] = 3.4, 95% confidence interval [CI] = 1.8-6.7), rarely or never drinking tap water (OR = 2.9, 95% CI = 1.3-6.6), insufficient tap water (OR = 3.0, 95% CI = 1.4-6.3), paying for bottled water (OR = 3.2, 95% CI = 1.2-8.7), and dissatisfaction with tap water were associated with self-reported health effects (n = 393); however, the effect of dissatisfaction was modified by respondent age ( P = .03). Quality and availability were associated with perceptions of health effects from drinking water, providing additional information on how ongoing concerns about drinking water influence self-reported health in some First Nations.
Moore, Ginny; Stevenson, David; Thompson, Katy-Anne; Parks, Simon; Ngabo, Didier; Bennett, Allan M; Walker, Jimmy T
2015-01-01
Hospital tap water is a recognised source of Pseudomonas aeruginosa. U.K. guidance documents recommend measures to control/minimise the risk of P. aeruginosa in augmented care units but these are based on limited scientific evidence. An experimental water distribution system was designed to investigate colonisation of hospital tap components. P. aeruginosa was injected into 27 individual tap 'assemblies'. Taps were subsequently flushed twice daily and contamination levels monitored over two years. Tap assemblies were systematically dismantled and assessed microbiologically and the effect of removing potentially contaminated components was determined. P. aeruginosa was repeatedly recovered from the tap water at levels above the augmented care alert level. The organism was recovered from all dismantled solenoid valves with colonisation of the ethylene propylene diene monomer (EPDM) diaphragm confirmed by microscopy. Removing the solenoid valves reduced P. aeruginosa counts in the water to below detectable levels. This effect was immediate and sustained, implicating the solenoid diaphragm as the primary contamination source.
Waldner, Cheryl L; Alimezelli, Hubert Tote; McLeod, Lianne; Zagozewski, Rebecca; Bradford, Lori EA; Bharadwaj, Lalita A
2017-01-01
Water-related health challenges on First Nations reserves in Canada have been previously documented. Our objective was to describe factors associated with self-reported health effects from tap water in 8 First Nations reserve communities in Saskatchewan, Canada. Community-based participatory approaches were used in designing and implementing cross-sectional household surveys. Individual, household, community, and contextual effects were considered in multilevel analysis. Negative health effects from tap water were reported by 28% of households (n = 579). Concerns about environmental factors affecting water quality (odds ratio [OR] = 3.4, 95% confidence interval [CI] = 1.8-6.7), rarely or never drinking tap water (OR = 2.9, 95% CI = 1.3-6.6), insufficient tap water (OR = 3.0, 95% CI = 1.4-6.3), paying for bottled water (OR = 3.2, 95% CI = 1.2-8.7), and dissatisfaction with tap water were associated with self-reported health effects (n = 393); however, the effect of dissatisfaction was modified by respondent age (P = .03). Quality and availability were associated with perceptions of health effects from drinking water, providing additional information on how ongoing concerns about drinking water influence self-reported health in some First Nations. PMID:28469443
Risk perceptions of arsenic in tap water and consumption of bottled water
NASA Astrophysics Data System (ADS)
Jakus, Paul M.; Shaw, W. Douglass; Nguyen, To N.; Walker, Mark
2009-05-01
The demand for bottled water has increased rapidly over the past decade, but bottled water is extremely costly compared to tap water. The convenience of bottled water surely matters to consumers, but are others factors at work? This manuscript examines whether purchases of bottled water are associated with the perceived risk of tap water. All of the past studies on bottled water consumption have used simple scale measures of perceived risk that do not correspond to risk measures used by risk analysts. We elicit a probability-based measure of risk and find that as perceived risks rise, expenditures for bottled water rise.
Liu, Gang; Zhang, Ya; van der Mark, Ed; Magic-Knezev, Aleksandra; Pinto, Ameet; van den Bogert, Bartholomeus; Liu, Wentso; van der Meer, Walter; Medema, Gertjan
2018-07-01
The general consensus is that the abundance of tap water bacteria is greatly influenced by water purification and distribution. Those bacteria that are released from biofilm in the distribution system are especially considered as the major potential risk for drinking water bio-safety. For the first time, this full-scale study has captured and identified the proportional contribution of the source water, treated water, and distribution system in shaping the tap water bacterial community based on their microbial community fingerprints using the Bayesian "SourceTracker" method. The bacterial community profiles and diversity analyses illustrated that the water purification process shaped the community of planktonic and suspended particle-associated bacteria in treated water. The bacterial communities associated with suspended particles, loose deposits, and biofilm were similar to each other, while the community of tap water planktonic bacteria varied across different locations in distribution system. The microbial source tracking results showed that there was not a detectable contribution of source water to bacterial community in the tap water and distribution system. The planktonic bacteria in the treated water was the major contributor to planktonic bacteria in the tap water (17.7-54.1%). The particle-associated bacterial community in the treated water seeded the bacterial community associated with loose deposits (24.9-32.7%) and biofilm (37.8-43.8%) in the distribution system. In return, the loose deposits and biofilm showed a significant influence on tap water planktonic and particle-associated bacteria, which were location dependent and influenced by hydraulic changes. This was revealed by the increased contribution of loose deposits to tap water planktonic bacteria (from 2.5% to 38.0%) and an increased contribution of biofilm to tap water particle-associated bacteria (from 5.9% to 19.7%) caused by possible hydraulic disturbance from proximal to distal regions. Therefore, our findings indicate that the tap water bacteria could possibly be managed by selecting and operating the purification process properly and cleaning the distribution system effectively. Copyright © 2018 Elsevier Ltd. All rights reserved.
Consumer Perception and Preference of Drinking Water Sources
Sajjadi, Seyed Ali; Alipour, Vali; Matlabi, Mohammad; Biglari, Hamed
2016-01-01
Introduction Understanding consumer perception of drinking water can contribute to improvements in water management and consumer satisfaction. The aim of this study was to assess the consumer perception of tap water quality and other drinking water sources in Gonabad as a small semiarid city. Methods This study was performed in autumn and winter 2013. For collection data a researcher-made a questionnaire consisting of nine questions, based on demographic information prepared. Questions were asked for participants to provide information regarding household drinking water usage and patterns, opinion about tap water safety, taste and reasons for purchasing bottled water. For statistical analysis, analysis of variance (ANOVA) using SPSS version 16 was applied in this study. Results Results showed that demographic variables had a significant relationship with consumer satisfaction (p < 0.05). Office employees, women and poor families had the most satisfaction from tap water quality. Peoples’ preferences for tap water, commercial softener, domestic softener, ghanat (a type of underground cistern) and bottled water were 27.8, 19, 27.8, 40.4 and 3.5% respectively. Dissatisfaction from production of foam, unsuitable taste, unacceptable appearance and other problems in tap water was 11.1, 95.6, 27.8 and 0.4% respectively. Consumer reasons for using domestic water softeners are: suitable taste (80%), easy availability (71%), economical (56%) and low health side effects (34%). Conclusion According to these results it was clear that each consumer group, based on self-condition, prefers using a specific drinking water source. PMID:28070256
Consumer Perception and Preference of Drinking Water Sources.
Sajjadi, Seyed Ali; Alipour, Vali; Matlabi, Mohammad; Biglari, Hamed
2016-11-01
Understanding consumer perception of drinking water can contribute to improvements in water management and consumer satisfaction. The aim of this study was to assess the consumer perception of tap water quality and other drinking water sources in Gonabad as a small semiarid city. This study was performed in autumn and winter 2013. For collection data a researcher-made a questionnaire consisting of nine questions, based on demographic information prepared. Questions were asked for participants to provide information regarding household drinking water usage and patterns, opinion about tap water safety, taste and reasons for purchasing bottled water. For statistical analysis, analysis of variance (ANOVA) using SPSS version 16 was applied in this study. Results showed that demographic variables had a significant relationship with consumer satisfaction (p < 0.05). Office employees, women and poor families had the most satisfaction from tap water quality. Peoples' preferences for tap water, commercial softener, domestic softener, ghanat (a type of underground cistern) and bottled water were 27.8, 19, 27.8, 40.4 and 3.5% respectively. Dissatisfaction from production of foam, unsuitable taste, unacceptable appearance and other problems in tap water was 11.1, 95.6, 27.8 and 0.4% respectively. Consumer reasons for using domestic water softeners are: suitable taste (80%), easy availability (71%), economical (56%) and low health side effects (34%). According to these results it was clear that each consumer group, based on self-condition, prefers using a specific drinking water source.
Säve-Söderbergh, Melle; Toljander, Jonas; Mattisson, Irene; Åkesson, Agneta; Simonsson, Magnus
2018-03-01
Studies have shown that the average drinking water consumption ranges between 0.075 and 3 L/day for adults with both national and regional differences. For exposure assessment of drinking water hazards, country-specific drinking water consumption data including sources of the consumed water may therefore be warranted. To estimate the amount and source of drinking water consumed among adults in Sweden, we collected self-reported estimates using both traditional methods (telephone interviews, web questionnaire) and a novel method (Short Message Service, SMS questionnaires) in a population from an average sized Swedish municipality. Monthly SMS questionnaires were sent out during one year to obtain longitudinal information as well. SMS showed to be a promising tool for collecting self-reported consumption, as most citizens could participate and the method showed high response rate. Data collected via the SMS questionnaire shows an average consumption of cold tap water of 4.9 glasses/24 h (one glass=200 ml), while the average estimates of cold tap water collected by the traditional methods range from 4.5 to 7.0 glasses/24 h. For statistical distributions, the mean daily consumption of cold tap water for the population was best fitted to a gamma distribution. About 70% of the cold tap water is consumed at home. Based on the results from the SMS study, we suggest using 1 l/day for the average adult population and 2.5 l/day for high consumers for risk assessment of cold tap water consumption. As 46% of the tap water consumed is heated, we suggest using 1.85 l/day for total tap water consumption.
Säve-Söderbergh, Melle; Toljander, Jonas; Mattisson, Irene; Åkesson, Agneta; Simonsson, Magnus
2018-01-01
Studies have shown that the average drinking water consumption ranges between 0.075 and 3 L/day for adults with both national and regional differences. For exposure assessment of drinking water hazards, country-specific drinking water consumption data including sources of the consumed water may therefore be warranted. To estimate the amount and source of drinking water consumed among adults in Sweden, we collected self-reported estimates using both traditional methods (telephone interviews, web questionnaire) and a novel method (Short Message Service, SMS questionnaires) in a population from an average sized Swedish municipality. Monthly SMS questionnaires were sent out during one year to obtain longitudinal information as well. SMS showed to be a promising tool for collecting self-reported consumption, as most citizens could participate and the method showed high response rate. Data collected via the SMS questionnaire shows an average consumption of cold tap water of 4.9 glasses/24 h (one glass=200 ml), while the average estimates of cold tap water collected by the traditional methods range from 4.5 to 7.0 glasses/24 h. For statistical distributions, the mean daily consumption of cold tap water for the population was best fitted to a gamma distribution. About 70% of the cold tap water is consumed at home. Based on the results from the SMS study, we suggest using 1 l/day for the average adult population and 2.5 l/day for high consumers for risk assessment of cold tap water consumption. As 46% of the tap water consumed is heated, we suggest using 1.85 l/day for total tap water consumption. PMID:28612838
[Volatile organic compounds of the tap water in the Watarase, Tone and Edo River system].
Ohmichi, Kimihide; Ohmichi, Masayoshi; Machida, Kazuhiko
2004-01-01
The chlorination of river water in purification plants is known to produce carcinogens such as trihalomethanes (THMs). We studied the river system of the Watarase, Tone, and Edo Rivers in regard to the formation of THMs. This river system starts from the base of the Ashio copper mine and ends at Tokyo Bay. Along the rivers, there are 14 local municipalities in Gunma, Saitama, Ibaragi and Chiba Prefectures, as well as Tokyo. This area is the center of the Kanto plain and includes the main sources of water pollution from human activities. We also analyzed various chemicals in river water and tap water to clarify the status of the water environment, and we outline the problems of the water environment in the research area (Fig. 1). Water samples were taken from 18 river sites and 42 water faucets at public facilities in 14 local municipalities. We analyzed samples for volatile organic compounds such as THMs, by gas chromatography mass spectrometry (GC-MS), and evaluations of chemical oxygen demand (COD) were made with reference to Japanese drinking water quality standards. Concentrations of THMs in the downstream tap water samples were higher than those in the samples from the upperstream. This tendency was similar to the COD of the river water samples, but no correlation between the concentration of THMs in tap water and the COD in tap water sources was found. In tap water of local government C, trichloroethylene was detected. The current findings suggest that the present water filtration plant procedures are not sufficient to remove some hazardous chemicals from the source water. Moreover, it was confirmed that the water filtration produced THMs. Also, trichloroethylene was detected from the water environment in the research area, suggesting that pollution of the water environment continues.
Onufrak, Stephen J; Park, Sohyun; Sharkey, Joseph R; Sherry, Bettylou
2015-01-01
Objective Research is limited on whether mistrust of tap water discourages plain water intake and leads to greater intake of sugar-sweetened beverages (SSB). The objective of this study is to examine demographic differences in perceptions of tap water safety and determine if these perceptions are associated with intake of SSB and plain water Design The study examined perceptions of tap water safety and their cross-sectional association with intake of SSB and plain water. Racial/ethnic differences in the associations of tap water perceptions with SSB and plain water intake were also examined. Setting Nationally weighted data from 2010 HealthStyles Survey (n=4184) Subjects United States adults ≥18 years Results Overall, 13.0% of participants disagreed that their local tap water was safe to drink and 26.4% of participants agreed that bottled water was safer than tap water. Both mistrust of tap water safety and favoring bottled water differed by region, age, race/ethnicity, income, and education. The associations of tap water mistrust on intake of SSB and plain water were modified by race/ethnicity (p<0.05). Non-white racial/ethnic groups who disagreed that their local tap water was safe to drink were more likely to report low intake of plain water. The odds of consuming ≥1 SSB/day among Hispanics who mistrusted their local tap water was twice that of Hispanics who did not (OR = 2.0; 95% CI: 1.2, 3.3). Conclusions Public health efforts to promote healthy beverages should recognize the potential impact of tap water perceptions on water and SSB intake among minority populations. PMID:23098620
Microbiological tap water profile of a medium-sized building and effect of water stagnation.
Lipphaus, Patrick; Hammes, Frederik; Kötzsch, Stefan; Green, James; Gillespie, Simon; Nocker, Andreas
2014-01-01
Whereas microbiological quality of drinking water in water distribution systems is routinely monitored for reasons of legal compliance, microbial numbers in tap water are grossly understudied. Motivated by gross differences in water from private households, we applied in this study flow cytometry as a rapid analytical method to quantify microbial concentrations in water sampled at diverse taps in a medium size research building receiving chlorinated water. Taps differed considerably in frequency of usage and were located in laboratories, bathrooms, and a coffee kitchen. Substantial differences were observed between taps with concentrations (per mL) in the range from 6.29 x 10(3) to 7.74 x 10(5) for total cells and from 1.66 x 10(3) to 4.31 x 10(5) for intact cells. The percentage of intact cells varied between 7% and 96%. Water from taps with very infrequent use showed the highest bacterial numbers and the highest proportions of intact cells. Stagnation tended to increase microbial numbers in water from those taps which were otherwise frequently used. Microbial numbers in other taps that were rarely opened were not affected by stagnation as their water is probably mostly stagnant. For cold water taps, microbial numbers and the percentage of intact cells tended to decline with flushing with the greatest decline for taps used least frequently whereas microbial concentrations in water from hot water taps tended to be somewhat more stable. We conclude that microbiological water quality is mainly determined by building-specific parameters. Tap water profiling can provide valuable insight into plumbing system hygiene and maintenance.
Judée, F; Simon, S; Bailly, C; Dufour, T
2018-04-15
Cold atmospheric plasmas are weakly ionized gases that can be generated in ambient air. They produce energetic species (e.g. electrons, metastables) as well as reactive oxygen species, reactive nitrogen species, UV radiations and local electric field. Their interaction with a liquid such as tap water can hence change its chemical composition. The resulting "plasma-activated liquid" can meet many applications, including medicine and agriculture. Consequently, a complete experimental set of analytical techniques dedicated to the characterization of long lifetime chemical species has been implemented to characterize tap water treated using cold atmospheric plasma process and intended to agronomy applications. For that purpose, colorimetry and acid titrations are performed, considering acid-base equilibria, pH and temperature variations induced during plasma activation. 16 species are quantified and monitored: hydroxide and hydronium ions, ammonia and ammonium ions, orthophosphates, carbonate ions, nitrite and nitrate ions and hydrogen peroxide. The related consumption/production mechanisms are discussed. In parallel, a chemical model of electrical conductivity based on Kohlrausch's law has been developed to simulate the electrical conductivity of the plasma-activated tap water (PATW). Comparing its predictions with experimental measurements leads to a narrow fitting, hence supporting the self-sufficiency of the experimental set, I.e. the fact that all long lifetime radicals of interest present in PATW are characterized. Finally, to evaluate the potential of cold atmospheric plasmas for agriculture applications, tap water has been daily plasma-treated to irrigate lentils seeds. Then, seedlings lengths have been measured and compared with untreated tap water, showing an increase as high as 34.0% and 128.4% after 3 days and 6 days of activation respectively. The interaction mechanisms between plasma and tap water are discussed as well as their positive synergy on agronomic results. Copyright © 2017 Elsevier Ltd. All rights reserved.
Molybdenum distributions and variability in drinking water from England and Wales.
Smedley, P L; Cooper, D M; Lapworth, D J
2014-10-01
An investigation has been carried out of molybdenum in drinking water from a selection of public supply sources and domestic taps across England and Wales. This was to assess concentrations in relation to the World Health Organization (WHO) health-based value for Mo in drinking water of 70 μg/l and the decision to remove the element from the list of formal guideline values. Samples of treated drinking water from 12 water supply works were monitored up to four times over an 18-month period, and 24 domestic taps were sampled from three of their supply areas. Significant (p < 0.05) differences were apparent in Mo concentration between sources. Highest concentrations were derived from groundwater from a sulphide-mineralised catchment, although concentrations were only 1.5 μg/l. Temporal variability within sites was small, and no seasonal effects (p > 0.05) were detected. Tap water samples collected from three towns (North Wales, the English Midlands, and South East England) supplied uniquely by upland reservoir water, river water, and Chalk groundwater, respectively, also showed a remarkable uniformity in Mo concentrations at each location. Within each, the variability was very small between houses (old and new), between pre-flush and post-flush samples, and between the tap water and respective source water samples. The results indicate that water distribution pipework has a negligible effect on supplied tap water Mo concentrations. The findings contrast with those for Cu, Zn, Ni, Pb, and Cd, which showed significant differences (p < 0.05) in concentrations between pre-flush and post-flush tap water samples. In two pre-flush samples, concentrations of Ni or Pb were above drinking water limits, although in all cases, post-flush waters were compliant. The high concentrations, most likely derived from metal pipework in the domestic distribution system, accumulated during overnight stagnation. The concentrations of Mo observed in British drinking water, in all cases less than 2 μg/l, were more than an order of magnitude below the WHO health-based value and suggest that Mo is unlikely to pose a significant health or water supply problem in England and Wales.
Jain, Meha; Lim, Yili; Arce-Nazario, Javier A; Uriarte, María
2014-01-01
Identifying which factors influence household water management can help policy makers target interventions to improve drinking water quality for communities that may not receive adequate water quality at the tap. We assessed which perceptional and socio-demographic factors are associated with household drinking water management strategies in rural Puerto Rico. Specifically, we examined which factors were associated with household decisions to boil or filter tap water before drinking, or to obtain drinking water from multiple sources. We find that households differ in their management strategies depending on the institution that distributes water (i.e. government PRASA vs community-managed non-PRASA), perceptions of institutional efficacy, and perceptions of water quality. Specifically, households in PRASA communities are more likely to boil and filter their tap water due to perceptions of low water quality. Households in non-PRASA communities are more likely to procure water from multiple sources due to perceptions of institutional inefficacy. Based on informal discussions with community members, we suggest that water quality may be improved if PRASA systems improve the taste and odor of tap water, possibly by allowing for dechlorination prior to distribution, and if non-PRASA systems reduce the turbidity of water at the tap, possibly by increasing the degree of chlorination and filtering prior to distribution. Future studies should examine objective water quality standards to identify whether current management strategies are effective at improving water quality prior to consumption.
Jain, Meha; Lim, Yili; Arce-Nazario, Javier A.; Uriarte, María
2014-01-01
Identifying which factors influence household water management can help policy makers target interventions to improve drinking water quality for communities that may not receive adequate water quality at the tap. We assessed which perceptional and socio-demographic factors are associated with household drinking water management strategies in rural Puerto Rico. Specifically, we examined which factors were associated with household decisions to boil or filter tap water before drinking, or to obtain drinking water from multiple sources. We find that households differ in their management strategies depending on the institution that distributes water (i.e. government PRASA vs community-managed non-PRASA), perceptions of institutional efficacy, and perceptions of water quality. Specifically, households in PRASA communities are more likely to boil and filter their tap water due to perceptions of low water quality. Households in non-PRASA communities are more likely to procure water from multiple sources due to perceptions of institutional inefficacy. Based on informal discussions with community members, we suggest that water quality may be improved if PRASA systems improve the taste and odor of tap water, possibly by allowing for dechlorination prior to distribution, and if non-PRASA systems reduce the turbidity of water at the tap, possibly by increasing the degree of chlorination and filtering prior to distribution. Future studies should examine objective water quality standards to identify whether current management strategies are effective at improving water quality prior to consumption. PMID:24586302
The δ2H and δ18O of tap water from 349 sites in the United States and selected territories
Coplen, Tyler B.; Landwehr, Jurate M.; Qi, Haiping; Lorenz, Jennifer M.
2013-01-01
Because the stable isotopic compositions of hydrogen (δ2H) and oxygen (δ18O) of animal (including human) tissues, such as hair, nail, and urine, reflect the δ2H and δ18O of water and food ingested by an animal or a human and because the δ2H and δ18O of environmental waters vary geographically, δ2H and δ18O values of tap water samples collected in 2007-2008 from 349 sites in the United States and three selected U.S. territories have been measured in support of forensic science applications, creating one of the largest databases of tap water δ2H and δ18O values to date. The results of replicate isotopic measurements for these tap water samples confirm that the expanded uncertainties (U = 2μc) obtained over a period of years by the Reston Stable Isotope Laboratory from δ2H and δ18O dual-inlet mass spectrometric measurements are conservative, at ±2‰ and ±0.2 ‰, respectively. These uncertainties are important because U.S. Geological Survey data may be needed for forensic science applications, including providing evidence in court cases. Half way through the investigation, an isotope-laser spectrometer was acquired, enabling comparison of dual-inlet isotope-ratio mass spectrometric results with isotope-laser spectrometric results. The uncertainty of the laser-based δ2H measurement results for these tap water samples is comparable to the uncertainty of the mass spectrometric method, with the laser-based method having a slightly lower uncertainty. However, the δ18O uncertainty of the laser-based method is more than a factor of ten higher than that of the dual-inlet isotoperatio mass spectrometric method.
Chen, Lu; Jia, Rui-Bao; Li, Li
2013-07-01
Bacteria in drinking water distribution systems can cause deterioration of the water quality, and the microbial quality of tap water is closely related to consumer health. In the present study, the potential effects of bacteria attached to cast iron pipes on tap water in a distribution system were investigated. Comparison of the bacterial community composition of pipe tubercles with that of stagnant tap water samples based on a denaturing gradient gel electrophoresis analysis of the 16S rRNA gene revealed that the communities were related. Specifically, the main bacterial members were identical to each other. The bacterial community was found to be dominated by Firmicutes, Actinobacteria, and Proteobacteria, which included Rhizobium, Pseudomonas, Lactococcus, Brevundimonas, Rheinheimera, Arthrobacter, Bacillus, and Herbaspirillum. Heterotrophic bacteria proliferation was observed during the period of stagnation, followed by a decrease of assimilable organic carbon and a slight increase of microbially available phosphorus. These findings indicated that the regrowth of bacteria might be boosted by the release of nutrients such as phosphorus from the pipe walls, as well as the decline of residual chlorine during stagnation. Inorganic contaminants at low levels, including Al, Mn, Zn, Pb, Cr, Cu, and Ni, were detected in tubercles and were concentrated in particulates from tap water following the release of iron during stagnation.
NASA Astrophysics Data System (ADS)
Sanz Lobón, Germán; Yepez, Alfonso; Garcia, Luane Ferreira; Morais, Ruiter Lima; Vaz, Boniek Gontijo; Carvalho, Veronica Vale; de Oliveira, Gisele Augusto Rodrigues; Luque, Rafael; Gil, Eric De Souza
2017-02-01
Microcystin-leucine arginine (MC-LR) is the most abundant and toxic secondary metabolite produced by freshwater cyanobacteria. This toxin has a high potential hazard health due to potential interactions with liver, kidney and the nervous system. The aim of this work was the design of a simple and environmentally friendly electrochemical system based on highly efficient nanostructured electrodes for the removal of MC-LR in tap water. Titania nanoparticles were deposited on carbon (graphite) under a simple and efficient microwave assisted approach for the design of the electrode, further utilized in the electrochemical remediation assays. Parameters including the applied voltage, time of removal and pH (natural tap water or alkaline condition) were investigated in the process, with results pointing to a high removal efficiency for MC-LR (60% in tap water and 90% in alkaline media experiments, under optimized conditions).
Sanz Lobón, Germán; Yepez, Alfonso; Garcia, Luane Ferreira; Morais, Ruiter Lima; Vaz, Boniek Gontijo; Carvalho, Veronica Vale; de Oliveira, Gisele Augusto Rodrigues; Luque, Rafael; Gil, Eric de Souza
2017-01-01
Microcystin-leucine arginine (MC-LR) is the most abundant and toxic secondary metabolite produced by freshwater cyanobacteria. This toxin has a high potential hazard health due to potential interactions with liver, kidney and the nervous system. The aim of this work was the design of a simple and environmentally friendly electrochemical system based on highly efficient nanostructured electrodes for the removal of MC-LR in tap water. Titania nanoparticles were deposited on carbon (graphite) under a simple and efficient microwave assisted approach for the design of the electrode, further utilized in the electrochemical remediation assays. Parameters including the applied voltage, time of removal and pH (natural tap water or alkaline condition) were investigated in the process, with results pointing to a high removal efficiency for MC-LR (60% in tap water and 90% in alkaline media experiments, under optimized conditions). PMID:28145477
Acanthamoeba keratitis: the role of domestic tap water contamination in the United Kingdom.
Kilvington, Simon; Gray, Trevor; Dart, John; Morlet, Nigel; Beeching, John R; Frazer, David G; Matheson, Melville
2004-01-01
The incidence of acanthamoeba keratitis (AK) in the UK is some 15 times that in the United States and seven times that in Holland. To investigate reasons for this higher frequency, a study of the role of domestic tap water as a potential source of AK was undertaken. Tap outlets from the homes of 27 patients with culture-proven AK were sampled and cultured for free-living amoebae (FLA). For all Acanthamoeba isolates, mitochondrial DNA (mtDNA) restriction fragment length polymorphisms (RFLPs) and cytochrome oxidase (cox 1/2) sequence typing was performed to determine the similarity between corneal and tap water isolates. FLA, including Acanthamoeba, were isolated from 24 (89%) of 27 homes, and the presence within the homes varied significantly with tap water temperature and location: 19 (76%) of 25 bathroom sink cold taps sampled compared with 6 (24%) of 25 hot and 9 (47%) of 19 kitchen cold taps compared with 3 (16%) of 19 of hot kitchen taps. Acanthamoeba were isolated from 8 (30%) of 27 homes (five bathroom sink cold taps, one cloakroom cold tap, one bath, and one bedroom sink mixer [hot/cold] taps). In six cases, identical Acanthamoeba mtDNA profiles were found for the clinical and home tap water isolates. In keeping with UK plumbing practice, 24 of 27 homes had internal roof water storage tanks to supply domestic taps, but the mains fed the kitchen cold tap. Water storage tanks promote colonization of domestic water with FLA, including Acanthamoeba, and hence increase the risk of AK. This accounts for the significantly greater incidence of AK in the UK and supports advice to avoid using tap water in contact lens care routines.
Furuhata, Katsunori; Kato, Yuko; Goto, Keiichi; Hara, Motonobu; Yoshida, Shin-ichi; Fukuyama, Masafumi
2006-01-01
Contamination of tap water by Methylobacterium species has become a serious concern in hospitals. This study was planned to examine the distribution of Methylobacterium species inhabiting tap water used in Japanese hospitals and antibiotic sensitivity of the isolates in 2004. Species identification of 58 isolates was performed based on the homology of a partial sequence of 16S rDNA. The dominant Methylobacterium species in hospital water were M. aquaticum and M. fujisawaense. To examine the biochemical properties of these isolates, a carbon source utilization was tested using an API50CH kit. The phenotypic character varied widely, and was not necessarily consistent with the results of phylogenic analysis based on the partial 16S rDNA sequence, suggesting that the biochemical properties are not suitable for identification of Methylobacterium species. The isolates were also subjected to antibiotic sensitivity tests. They were resistant to 8 antibiotics, but highly sensitive to imipenem (MIC90 = 1 microg/ml) and tetracycline (MIC90 = 8 microg/ml). These findings concerning the isolates revealed the presence of Methylobacterium species with resistance to multiple antibiotics in hospital tap water.
Levels of major and trace elements, including rare earth elements, and ²³⁸U in Croatian tap waters.
Fiket, Željka; Rožmarić, Martina; Krmpotić, Matea; Benedik, Ljudmila
2015-05-01
Concentrations of 46 elements, including major, trace, and rare earth elements, and (238)U in Croatian tap waters were investigated. Selected sampling locations include tap waters from various hydrogeological regions, i.e., different types of aquifers, providing insight into the range of concentrations of studied elements and (238)U activity concentrations in Croatian tap waters. Obtained concentrations were compared with the Croatian maximum contaminant levels for trace elements in water intended for human consumption, as well as WHO and EPA drinking water standards. Concentrations in all analyzed tap waters were found in accordance with Croatian regulations, except tap water from Šibenik in which manganese in concentration above maximum permissible concentration (MPC) was measured. Furthermore, in tap water from Osijek, levels of arsenic exceeded the WHO guidelines and EPA regulations. In general, investigated tap waters were found to vary considerably in concentrations of studied elements, including (238)U activity concentrations. Causes of variability were further explored using statistical methods. Composition of studied tap waters was found to be predominately influenced by hydrogeological characteristics of the aquifer, at regional and local level, the existing redox conditions, and the household plumbing system. Rare earth element data, including abundances and fractionation patterns, complemented the characterization and facilitated the interpretation of factors affecting the composition of the analyzed tap waters.
Water use and time analysis in ablution from taps
NASA Astrophysics Data System (ADS)
Zaied, Roubi A.
2017-09-01
There is a lack of water resources and an extreme use of potable water in our Arab region. Ablution from taps was studied since it is a repeated daily activity that consumes more water. Five different tap types are investigated for water consumption fashions including traditional mixing tap and automatic tap. Analyzing 100 experimental observations revealed that 22.7-28.8 % of ablution water is used for washing of feet and the largest water waste occurs during washing of face portions. Moreover, 30-47 % amount of water consumed in ablution from taps is wasted which can be saved if tap releases water only at moments of need. The push-type tap is being spread recently especially in airports. If it is intended for use in ablution facilities, batch duration and volume must be tuned. When each batch is 0.25 L of water and lasts for 3 s, 3 L are sufficient for one complete ablution in average which means considerable saving. A cost-benefit model is proposed for using different tap types and an economic feasibility study is performed on a case study. This analysis can help us to design better ablution systems.
Leurs, Lina J; Schouten, Leo J; Mons, Margreet N; Goldbohm, R Alexandra; van den Brandt, Piet A
2010-03-01
Conflicting results on the relationship between the hardness of drinking water and mortality related to ischemic heart disease (IHD) or stroke have been reported. We investigated the possible association between tap water calcium or magnesium concentration and total hardness and IHD mortality or stroke mortality. In 1986, a cohort of 120,852 men and women aged 5569 years provided detailed information on dietary and other lifestyle habits. Follow-up for mortality until 1996 was established by linking data from the Central Bureau of Genealogy and Statistics Netherlands. We calculated tap water hardness for each postal code using information obtained from all pumping stations in the Netherlands. Tap water hardness was categorized as soft [< 1.5 mmol/L calcium carbonate (CaCO3)], medium hard (1.62.0 mmol/L CaCO3), and hard (> 2.0 mmol/L CaCO3). The multivariate case-cohort analysis was based on 1,944 IHD mortality and 779 stroke mortality cases and 4,114 subcohort members. For both men and women, we observed no relationship between tap water hardness and IHD mortality [hard vs. soft water: hazard ratio (HR) = 1.03; 95% confidence interval (CI), 0.851.28 for men and HR = 0.93; 95% CI, 0.711.21 for women) and stroke mortality (hard vs. soft water HR = 0.90; 95% CI, 0.661.21 and HR = 0.86; 95% CI, 0.621.20, respectively). For men with the 20% lowest dietary magnesium intake, an inverse association was observed between tap water magnesium intake and stroke mortality (HR per 1 mg/L intake = 0.75; 95% CI, 0.610.91), whereas for women with the 20% lowest dietary magnesium intake, the opposite was observed. We found no evidence for an overall significant association between tap water hardness, magnesium or calcium concentrations, and IHD mortality or stroke mortality. More research is needed to investigate the effect of tap water magnesium on IHD mortality or stroke mortality in subjects with low dietary magnesium intake.
van Erp, Brianna; Webber, Whitney L; Stoddard, Pamela; Shah, Roshni; Martin, Lori; Broderick, Bonnie; Induni, Marta
2014-06-12
The objective of this study was to examine differences in tap water consumption and perceptions of bottle versus tap water safety for Hispanics and non-Hispanic whites, as well as associations with other demographic characteristics. Data are from the Santa Clara County, California, Dietary Practices Survey (2011; N = 306). We used logistic regression to examine associations between demographic characteristics and 1) perceptions that bottled water is safer than tap and 2) primarily consuming tap water. Hispanics were less likely than non-Hispanic whites to primarily drink tap water (OR = 0.33; 95% CI, 0.11-0.99), although there was no significant difference in perceptions that bottled water is safer between these groups (OR = 0.50; 95% CI, 0.11-2.27). Hispanics may be an important population for interventions promoting tap water consumption.
Durand, Mary Alison; Green, Judith; Edwards, Phil; Milton, Sarah; Lutchmun, Suzanne
2012-06-01
Young children and older people are particularly vulnerable to tap water scalding. For children, there are also socio-economic inequalities in risk. Evidence suggests that reducing tap water temperatures in social (public) housing through 'passive' means is effective in reducing risk. However, little is known about parents' or older people's perceptions of scald risk and prevention. This study aimed to document the views of parents and older residents in social housing in an inner-London borough about their tap water temperature, perceived scalding risk and scald prevention strategies. Analysis of twenty in-depth interviews with 11 parents and 10 people aged 65 years or older. Tap water was described as very hot, but participants did not consider themselves at risk, viewing scald prevention as a personal responsibility achieved with a range of everyday, routine strategies. Very hot water was preferred for health- and convenience-related reasons. However, it was felt that others, particularly children, could be scalded, and some concern was expressed about the environmental and financial impacts of excessively hot water. Those seeking to introduce engineering-based scald prevention interventions in social housing should emphasise the potential environmental and financial impacts of water temperature reduction, in addition to promoting safety benefits for vulnerable others. Copyright © 2011 Elsevier Ltd and ISBI. All rights reserved.
Aktas, Dilber; Celebi, Bekir; Isik, Mehmet Emirhan; Tutus, Celal; Ozturk, Huseyin; Temel, Fehminaz; Kizilaslan, Mecit; Zhu, Bao-Ping
2015-12-01
In 2013, an oropharyngeal tularemia outbreak in Turkey affected 55 persons. Drinking tap water during the likely exposure period was significantly associated with illness (attack rate 27% vs. 11% among non-tap water drinkers). Findings showed the tap water source had been contaminated by surface water, and the chlorination device malfunctioned.
Kırış, Sevilay; Velioglu, Yakup Sedat
2016-01-01
The effects of different wash times (2 and 5 min) with tap and ozonated water on the removal of nine pesticides from olives and the transfer ratios of these pesticides during olive oil production were determined. The reliability of the analytical methods was also tested. The applied methods of analysis were found to be suitable based on linearity, trueness, repeatability, selectivity and limit of quantification all the pesticides tested. All tap and ozonated water wash cycles removed a significant quantity of the pesticides from the olives, with a few exceptions. Generally, extending the wash time increased the pesticide reduction with ozonated water, but did not make significant differences with tap water. During olive oil processing, depending on the processing technique and physicochemical properties of the pesticides, eight of nine pesticides were concentrated into olive oil (processing factor > 1) with almost no significant difference between treatments. Imidacloprid did not pass into olive oil. Ozonated water wash for 5 min reduced chlorpyrifos, β-cyfluthrin, α-cypermethrin and imidacloprid contents by 38%, 50%, 55% and 61% respectively in olives.
Measuring household consumption and waste in unmetered, intermittent piped water systems
NASA Astrophysics Data System (ADS)
Kumpel, Emily; Woelfle-Erskine, Cleo; Ray, Isha; Nelson, Kara L.
2017-01-01
Measurements of household water consumption are extremely difficult in intermittent water supply (IWS) regimes in low- and middle-income countries, where water is delivered for short durations, taps are shared, metering is limited, and household storage infrastructure varies widely. Nonetheless, consumption estimates are necessary for utilities to improve water delivery. We estimated household water use in Hubli-Dharwad, India, with a mixed-methods approach combining (limited) metered data, storage container inventories, and structured observations. We developed a typology of household water access according to infrastructure conditions based on the presence of an overhead storage tank and a shared tap. For households with overhead tanks, container measurements and metered data produced statistically similar consumption volumes; for households without overhead tanks, stored volumes underestimated consumption because of significant water use directly from the tap during delivery periods. Households that shared taps consumed much less water than those that did not. We used our water use calculations to estimate waste at the household level and in the distribution system. Very few households used 135 L/person/d, the Government of India design standard for urban systems. Most wasted little water even when unmetered, however, unaccounted-for water in the neighborhood distribution systems was around 50%. Thus, conservation efforts should target loss reduction in the network rather than at households.
Sources of drinking water in a pediatric population.
Jadav, Urvi G; Acharya, Bhavini S; Velasquez, Gisela M; Vance, Bradley J; Tate, Robert H; Quock, Ryan L
2014-01-01
The purpose of this study was to determine the primary sources of water used for consumption and cooking by the patients of a university-based pediatric dental practice. A simple, prewritten questionnaire-consisting of seven questions and available in English and Spanish-was conducted verbally with the caregivers of 123 pediatric patients during a designated timeframe. Analysis of responses included descriptive statistics and a chi-square test for a single proportion. Nonfiltered tap water accounted for the primary drinking water source in only 10 percent of the respondents. Firty-two percent of the respondents selected bottled water as the primary source of drinking water, and 24 percent selected vended water stations as a primary drinking water source. Nonfiltered tap water was much more likely to be utilized in cooking (58 percent). The majority of the patients in this study's pediatric dental practice do not consume fluoridated tap water. With the vast majority of the patients primarily consuming bottled or vended water, these patients are likely missing out on the caries-protective effects of water fluoridation.
Pant, Narayan Dutt; Poudyal, Nimesh; Bhattacharya, Shyamal Kumar
2016-06-07
Water-related diseases are of great concern in developing countries like Nepal. Every year, there are countless morbidity and mortality due to the consumption of unsafe drinking water. Recently, there have been increased uses of bottled drinking water in an assumption that the bottled water is safer than the tap water and its use will help to protect from water-related diseases. So, the main objective of this study was to analyze the bacteriological quality of bottled drinking water and that of municipal tap water. A total of 100 samples (76 tap water and 24 bottled water) were analyzed for bacteriological quality and pH. The methods used were spread plate method for total plate count (TPC) and membrane filter method for total coliform count (TCC), fecal coliform count (FCC), and fecal streptococcal count (FSC). pH meter was used for measuring pH. One hundred percent of the tap water samples and 87.5 % of the bottled water samples were found to be contaminated with heterotrophic bacteria. Of the tap water samples, 55.3 % were positive for total coliforms, compared with 25 % of the bottled water. No bottled water samples were positive for fecal coliforms and fecal streptococci, in contrast to 21.1 % and 14.5 % of the tap water samples being contaminated with fecal coliforms and fecal streptococci, respectively. One hundred percent of the tap water samples and 54.2 % of the bottled water samples had pH in the acceptable range. All of the municipal tap water samples and most of the bottled drinking water samples distributed in Dharan municipality were found to be contaminated with one or more than one type of indicator organisms. On the basis of our findings, we may conclude that comparatively, the bottled drinking water may have been safer (than tap water) to drink.
Zhang, Hongyan; Yang, Liquan; Zhou, Bingjiang; Liu, Weimin; Ge, Jiechao; Wu, Jiasheng; Wang, Ying; Wang, Pengfei
2013-09-15
An ultrasensitive and selective detection of mercury (II) was investigated using a laser scanning confocal imaging-surface plasmon resonance system (LSCI-SPR). The detection limit was as low as 0.01ng/ml for Hg(2+) ions in ultrapure and tap water based on a T-rich, single-stranded DNA (ssDNA)-modified gold film, which can be individually manipulated using specific T-Hg(2+)-T complex formation. The quenching intensity of the fluorescence images for rhodamine-labeled ssDNA fitted well with the changes in SPR. The changes varied with the Hg(2+) ion concentration, which is unaffected by the presence of other metal ions. The coefficients obtained for ultrapure and tap water were 0.99902 and 0.99512, respectively, for the linear part over a range of 0.01-100ng/ml. The results show that the double-effect sensor has potential for practical applications with ultra sensitivity and selectivity, especially in online or real-time monitoring of Hg(2+) ions pollution in tap water with the further improvement of portable LSCI-SPR instrument. Copyright © 2013 Elsevier B.V. All rights reserved.
Bottled, filtered, and tap water use in Latino and non-Latino children.
Hobson, Wendy L; Knochel, Miguel L; Byington, Carrie L; Young, Paul C; Hoff, Charles J; Buchi, Karen F
2007-05-01
To describe bottled, filtered, and tap water consumption and fluoride use among pediatric patients; to analyze differences between ethnic and socioeconomic groups; and to describe the frequency of physician-parent discussions regarding water consumption. Convenience sample survey. An urban public health clinic. Parents attending a public health clinic. The primary outcome measure was the prevalence of tap, filtered, and bottled water use. The secondary outcome measures were supplemental fluoride use and the percentage of patients reporting discussions of water consumption with their physician. A total of 216 parents (80.5% Latino and 19.5% non-Latino) completed the survey. Of the parents, 30.1% never drank tap water and 41.2% never gave it to their children. Latino parents were less likely than non-Latino parents to drink tap water (odds ratio, 0.26; 95% confidence interval, 0.10-0.67) and less likely to give tap water to their children (odds ratio, 0.32; 95% confidence interval, 0.15-0.70). More Latinos believed that tap water would make them sick (odds ratio, 5.63; 95% confidence interval, 2.17-14.54). Approximately 40% of children who never drank tap water were not receiving fluoride supplements. Of the lowest-income families (
Microprocessor controlled anodic stripping voltameter for trace metals analysis in tap water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clem, R.G.; Park, F.W.; Kirsten, F.A.
1981-04-01
The construction and use of a portable, microprocessor controlled anodic stripping voltameter for on-site simultaneous metal analysis of copper, lead and cadmium in tap water is discussed. The instrumental system is comprised of a programmable controller which permits keying in analytical parameters such as sparge time and plating time; a rotating cell for efficient oxygen removal and amalgam formation; and, a magnetic tape which can be used for data storage. Analysis time can be as short as 10 to 15 minutes. The stripping analysis is based on a pre-measurement step during which the metals from a water sample are concentratedmore » into a thin mercury film by deposition from an acetate solution of pH 4.5. The concentrated metals are then electrochemically dissolved from the film by application of a linearly increasing anodic potential. Typical peak-shaped curves are obtained. The heights of these curves are related to the concentration of metals in the water by calibration data. Results of tap water analysis showed 3 +- 1 ..mu..g/L lead, 22 +- 0.3 ..mu..g/L copper, and less than 0.2 ..mu..g/L cadmium for a Berkeley, California tap water, and 1 to 1000 ..mu..g/L Cu, 1 to 2 ..mu..g/L Pb for ten samples of Seattle, Washington tap water. Recommendations are given for a next generation instrument system.« less
Comparison of the Mineral Content of Tap Water and Bottled Waters
Azoulay, Arik; Garzon, Philippe; Eisenberg, Mark J
2001-01-01
OBJECTIVES Because of growing concern that constituents of drinking water may have adverse health effects, consumption of tap water in North America has decreased and consumption of bottled water has increased. Our objectives were to 1) determine whether North American tap water contains clinically important levels of calcium (Ca2+), magnesium (Mg2+), and sodium (Na+) and 2) determine whether differences in mineral content of tap water and commercially available bottled waters are clinically important. DESIGN We obtained mineral analysis reports from municipal water authorities of 21 major North American cities. Mineral content of tap water was compared with published data regarding commercially available bottled waters and with dietary reference intakes (DRIs). MEASUREMENTS AND MAIN RESULTS Mineral levels varied among tap water sources in North America and among bottled waters. European bottled waters generally contained higher mineral levels than North American tap water sources and North American bottled waters. For half of the tap water sources we examined, adults may fulfill between 8% and 16% of their Ca2+ DRI and between 6% and 31% of their Mg2+ DRI by drinking 2 liters per day. One liter of most moderate mineralization European bottled waters contained between 20% and 58% of the Ca2+ DRI and between 16% and 41% of the Mg2+ DRI in adults. High mineralization bottled waters often contained up to half of the maximum recommended daily intake of Na+. CONCLUSION Drinking water sources available to North Americans may contain high levels of Ca2+, Mg2+, and Na+ and may provide clinically important portions of the recommended dietary intake of these minerals. Physicians should encourage patients to check the mineral content of their drinking water, whether tap or bottled, and choose water most appropriate for their needs. PMID:11318912
Microbiological evaluation of water during the 2011 flood crisis in Thailand.
Chaturongkasumrit, Yuphakhun; Techaruvichit, Punnida; Takahashi, Hajime; Kimura, Bon; Keeratipibul, Suwimon
2013-10-01
In 2011, a severe flood occurred in Thailand, covering nearly half the country in water for several months. The contamination of floodwater and subsequent contamination of water for human consumption could have potentially led to a widespread health crisis. However, to date, no study has been conducted to determine the safety of the waters used for human consumption in Thailand during the severe flood. Therefore, we conducted microbiological analysis of 4 kinds of water (floodwater, river water, tap water, and filtered tap water) collected from industrial and residential areas that were damaged due to flooding. Higher net levels of bacteria were found in water with a higher turbidity. No clear trend was observed in the pH value of all 4 water samples. The level of total bacterial contamination in the water samples was estimated by real-time quantitative polymerase chain reaction (PCR). Eleven of the 12 tap water samples and all of the filtered tap water samples had a total bacterial load that exceeded the Thai water quality standards. One of the tap water samples and one of the filtered tap water samples were found to be positive for Shigella sp., although none of the floodwater samples showed detectable levels of this pathogen as determined by PCR analysis. One of the samples of floodwater was also found to be positive for Leptospira sp., but none of the tap water or filtered tap water samples were positive. Most of the tap water samples and all filtered tap water samples were found to be contaminated with Vibrio cholerae. Bacterial contamination in water samples was also analyzed by denaturing gradient gel electrophoresis (DGGE) analysis. These results revealed that several microorganisms were transferred via floodwater to different areas in the central part of Thailand and cross-contaminated between floodwater and water for human consumption. © 2013.
Hill, Vincent R.; Kahler, Amy M.; Jothikumar, Narayanan; Johnson, Trisha B.; Hahn, Donghyun; Cromeans, Theresa L.
2007-01-01
Ultrafiltration (UF) is increasingly being recognized as a potentially effective procedure for concentrating and recovering microbes from large volumes of water and treated wastewater. Because of their very small pore sizes, UF membranes are capable of simultaneously concentrating viruses, bacteria, and parasites based on size exclusion. In this study, a UF-based water sampling procedure was used to simultaneously recover representatives of these three microbial classes seeded into 100-liter samples of tap water collected from eight cities covering six hydrologic areas of the United States. The UF-based procedure included hollow-fiber UF as the primary step for concentrating microbes and then used membrane filtration for bacterial culture assays, immunomagnetic separation for parasite recovery and quantification, and centrifugal UF for secondary concentration of viruses. Water samples were tested for nine water quality parameters to investigate whether water quality data correlated with measured recovery efficiencies and molecular detection levels. Average total method recovery efficiencies were 71, 97, 120, 110, and 91% for φX174 bacteriophage, MS2 bacteriophage, Enterococcus faecalis, Clostridium perfringens spores, and Cryptosporidium parvum oocysts, respectively. Real-time PCR and reverse transcription-PCR (RT-PCR) for seeded microbes and controls indicated that tap water quality could affect the analytical performance of molecular amplification assays, although no specific water quality parameter was found to correlate with reduced PCR or RT-PCR performance. PMID:17483281
Ander, E L; Watts, M J; Smedley, P L; Hamilton, E M; Close, R; Crabbe, H; Fletcher, T; Rimell, A; Studden, M; Leonardi, G
2016-12-01
Tap water from 497 properties using private water supplies, in an area of metalliferous and arsenic mineralisation (Cornwall, UK), was measured to assess the extent of compliance with chemical drinking water quality standards, and how this is influenced by householder water treatment decisions. The proportion of analyses exceeding water quality standards were high, with 65 % of tap water samples exceeding one or more chemical standards. The highest exceedances for health-based standards were nitrate (11 %) and arsenic (5 %). Arsenic had a maximum observed concentration of 440 µg/L. Exceedances were also high for pH (47 %), manganese (12 %) and aluminium (7 %), for which standards are set primarily on aesthetic grounds. However, the highest observed concentrations of manganese and aluminium also exceeded relevant health-based guidelines. Significant reductions in concentrations of aluminium, cadmium, copper, lead and/or nickel were found in tap waters where households were successfully treating low-pH groundwaters, and similar adventitious results were found for arsenic and nickel where treatment was installed for iron and/or manganese removal, and successful treatment specifically to decrease tap water arsenic concentrations was observed at two properties where it was installed. However, 31 % of samples where pH treatment was reported had pH < 6.5 (the minimum value in the drinking water regulations), suggesting widespread problems with system maintenance. Other examples of ineffectual treatment are seen in failed responses post-treatment, including for nitrate. This demonstrates that even where the tap waters are considered to be treated, they may still fail one or more drinking water quality standards. We find that the degree of drinking water standard exceedances warrant further work to understand environmental controls and the location of high concentrations. We also found that residents were more willing to accept drinking water with high metal (iron and manganese) concentrations than international guidelines assume. These findings point to the need for regulators to reinforce the guidance on drinking water quality standards to private water supply users, and the benefits to long-term health of complying with these, even in areas where treated mains water is widely available.
Dupont, Diane; Waldner, Cheryl; Bharadwaj, Lalita; Plummer, Ryan; Carter, Blair; Cave, Kate; Zagozewski, Rebecca
2014-05-30
The relationship between tap water and health has been a topic of public concern and calls for better management in Canada since well-publicized contamination events in two provinces (Ontario and Saskatchewan) in 2000-2001. This study reports the perspectives on health risks from tap water and corresponding use of, and spending on, bottled water in a number of different communities in Canada. In 2009-2010, four First Nations communities (three from Ontario and one from Saskatchewan) and a geographically diverse sample of non-First Nations Canadians were surveyed about their beliefs concerning health risks from tap water and their spending practices for bottled water as a substitute. Responses to five identical questions were examined, revealing that survey respondents from Ontario First Nations communities were more likely than non-First Nations Canadians to believe bottled water is safer than tap water (OR 1.6); more likely to report someone became ill from tap water (OR 3.6); more likely to express water and health concerns related to tap water consumption (OR 2.4); and more likely to spend more on bottled water (OR 4.9). On the other hand, participants from one Saskatchewan First Nations community were less likely than non-First Nations Canadians to believe that someone had become ill from drinking tap water (OR 3.8), less likely to believe bottled water is safer than tap (OR 2.0), and less likely to have health concerns with tap water (OR 1.5). These differences, however, did not translate into differences in the likelihood of high bottled water expenditures or being a 100% bottled water consumer. The paper discusses how the differences observed may be related to water supply and regulation, trust, perceived control, cultural background, location, and past experience.
Eichler, Stefan; Christen, Richard; Höltje, Claudia; Westphal, Petra; Bötel, Julia; Brettar, Ingrid; Mehling, Arndt; Höfle, Manfred G.
2006-01-01
Bacterial community dynamics of a whole drinking water supply system (DWSS) were studied from source to tap. Raw water for this DWSS is provided by two reservoirs with different water characteristics in the Harz mountains of Northern Germany. Samples were taken after different steps of treatment of raw water (i.e., flocculation, sand filtration, and chlorination) and at different points along the supply system to the tap. RNA and DNA were extracted from the sampled water. The 16S rRNA or its genes were partially amplified by reverse transcription-PCR or PCR and analyzed by single-strand conformation polymorphism community fingerprints. The bacterial community structures of the raw water samples from the two reservoirs were very different, but no major changes of these structures occurred after flocculation and sand filtration. Chlorination of the processed raw water strongly affected bacterial community structure, as reflected by the RNA-based fingerprints. This effect was less pronounced for the DNA-based fingerprints. After chlorination, the bacterial community remained rather constant from the storage containers to the tap. Furthermore, the community structure of the tap water did not change substantially for several months. Community composition was assessed by sequencing of abundant bands and phylogenetic analysis of the sequences obtained. The taxonomic compositions of the bacterial communities from both reservoirs were very different at the species level due to their different limnologies. On the other hand, major taxonomic groups, well known to occur in freshwater, such as Alphaproteobacteria, Betaproteobacteria, and Bacteroidetes, were found in both reservoirs. Significant differences in the detection of the major groups were observed between DNA-based and RNA-based fingerprints irrespective of the reservoir. Chlorination of the drinking water seemed to promote growth of nitrifying bacteria. Detailed analysis of the community dynamics of the whole DWSS revealed a significant influence of both source waters on the overall composition of the drinking water microflora and demonstrated the relevance of the raw water microflora for the drinking water microflora provided to the end user. PMID:16517632
Aragón, Tomás J; Novotny, Suzanne; Enanoria, Wayne; Vugia, Duc J; Khalakdina, Asheena; Katz, Mitchell H
2003-01-01
Background In persons with acquired immunodeficiency syndrome (AIDS), Cryptosporidium parvum causes a prolonged, severe diarrheal illness to which there is no effective treatment, and the risk of developing cryptosporidiosis from drinking tap water in non-outbreak settings remains uncertain. To test the hypothesis that drinking tap water was associated with developing cryptosporidiosis, we conducted a matched case-control study among persons with AIDS in San Francisco. Methods Among patients reported to the San Francisco AIDS Registry from May 1996 through September 1998, we compared patients who developed cryptosporidiosis to those who did not. Cases were individually matched to controls based on age, sex, race/ethnicity, CD4+ T lymphocyte count, date of CD4+ count, and date of case diagnosis. Population attributable fractions (PAFs) were calculated. Results The study consisted of 49 cases and 99 matched controls. In the multivariable analysis with adjustments for confounders, tap water consumption inside and outside the home at the highest exposure categories was associated with the occurrence of cryptosporidiosis (inside the home: odds ratio (OR), 6.76; 95% CI 1.37–33.5, and outside the home: OR 3.16; 95% CI 1.23–8.13). The PAF was 85%; that is, the proportion of cases of cryptosporidiosis in San Francisco AIDS patients attributable to tap water consumption could have been as high as 85%. Conclusions Although the results from this observational study cannot be considered definitive, until there is more data, we recommend persons with AIDS, especially those with compromised immune systems, consider avoiding tap water. PMID:12515584
Aragón, Tomás J; Novotny, Suzanne; Enanoria, Wayne; Vugia, Duc J; Khalakdina, Asheena; Katz, Mitchell H
2003-01-06
In persons with acquired immunodeficiency syndrome (AIDS), Cryptosporidium parvum causes a prolonged, severe diarrheal illness to which there is no effective treatment, and the risk of developing cryptosporidiosis from drinking tap water in non-outbreak settings remains uncertain. To test the hypothesis that drinking tap water was associated with developing cryptosporidiosis, we conducted a matched case-control study among persons with AIDS in San Francisco. Among patients reported to the San Francisco AIDS Registry from May 1996 through September 1998, we compared patients who developed cryptosporidiosis to those who did not. Cases were individually matched to controls based on age, sex, race/ethnicity, CD4+ T lymphocyte count, date of CD4+ count, and date of case diagnosis. Population attributable fractions (PAFs) were calculated. The study consisted of 49 cases and 99 matched controls. In the multivariable analysis with adjustments for confounders, tap water consumption inside and outside the home at the highest exposure categories was associated with the occurrence of cryptosporidiosis (inside the home: odds ratio (OR), 6.76; 95% CI 1.37-33.5, and outside the home: OR 3.16; 95% CI 1.23-8.13). The PAF was 85%; that is, the proportion of cases of cryptosporidiosis in San Francisco AIDS patients attributable to tap water consumption could have been as high as 85%. Although the results from this observational study cannot be considered definitive, until there is more data, we recommend persons with AIDS, especially those with compromised immune systems, consider avoiding tap water.
Evaluation on the Quality of Bangkok Tap Water with Other Drinking Purpose Water
NASA Astrophysics Data System (ADS)
Kordach, A.; Chardwattananon, C.; Wongin, K.; Chayaput, B.; Wongpat, N.
2018-02-01
The concern of drinking purposed water quality in Bangkok, Nonthaburi, and Samutprakarn provinces has been a problem for over fifteen years. Metropolitan Water Works Authority (MWA) of Thailand is fully responsible for providing water supply to the mentioned areas. The objective of Drinkable Tap Water Project is to make people realize in quality of tap water. Communities, school, government agencies, hotels, hospitals, department stores, and other organizations are participating in this project. MWA have collected at least 3 samples of water from the corresponding places and the samples have to meet the World Health Organization (WHO) guidelines level. This study is to evaluate water quality of tap water, storage water, filtered water, and filtered water dispenser. The water samples from 2,354 attending places are collected and analyzed. From October 2011 to September 2016, MWA analyzed 32,711 samples. The analyzed water parameters are free residual chlorine, appearance color, turbidity, pH, conductivity, total dissolved solids (TDS), and pathogenic bacteria; E.coli. The results indicated that a number of tap water samples had the highest number compliance with WHO guidelines levels at 98.40%. The filtered water, filtered water dispenser, and storage water were received 96.71%, 95.63%, and 90.88%, respectively. However, the several samples fail to pass WHO guideline level because they were contaminated by E.coli. The result is that tap water has the highest score among other sources probably because tap water has chlorine for disinfection and always is monitored by professional team round-the-clock services compared to the other water sources with less maintenance or cleaning. Also, water quality reports are continuously sent to customers by mail addresses. Tap water quality data are shown on MWA websites and Facebook. All these steps of work should enhance the confidence of tap water quality.
Calcium contained tap water phenomena: students misconception patterns of acids-bases concept
NASA Astrophysics Data System (ADS)
Liliasari, S.; Albaiti, A.; Wahyudi, A.
2018-05-01
Acids and bases concept is very important and fundamental concept in learning chemistry. It is one of the chemistry subjects considered as an abstract and difficult concept to understand. The aim of this research was to explore student’s misconception pattern about acids and bases phenomena in daily life, such as calcium contained tap water. This was a qualitative research with descriptive methods. Participants were 546 undergraduate students of chemistry education and chemistry program, and graduate students of chemistry education in West Java, Indonesia. The test to explore students’ misconception about this phenomena was essay test. The results showed that there were five patterns of students’ misconception in explaining the phenomena of calcium carbonate precipitation on heating tap water. Students used irrelevant concepts in explaining this phenomena, i.e. temporary hardness, coagulation, density, and phase concepts. No students had right answer in explaining this phenomena. This research contributes to design meaningful learning and to achieve better understanding.
Onufrak, Stephen J; Park, Sohyun; Sharkey, Joseph R; Merlo, Caitlin; Dean, Wesley R.; Sherry, Bettylou
2015-01-01
BACKGROUND Little is known regarding youth perceptions of tap water and school water fountains and how these relate to water and sugar-sweetened beverage (SSB) intake. METHODS We used national 2010 YouthStyles data to assess perceptions of tap water and school water fountains and associations with water and SSB intake. RESULTS Nearly 1 in 5 participants disagreed their tap water was safe and nearly 2 in 5 disagreed school water fountains were clean and safe. Perceived tap water risk was more prevalent among non-Hispanic (NH) blacks (26.4%) and Hispanics (28.3%) compared to NH whites (14.7%, p < .001) and more prevalent among lower income youth. Negative water fountain perceptions were more common among high school age youth. Perceived tap water risk was not associated with SSB intake (odds ratio (OR) = 1.0, 95% CI: 0.6, 1.5) or water intake (OR = 1.4, 95% CI: 0.9, 2.1). Negative water fountain perceptions were associated with SSB intake only among Hispanics (race/ethnicity interaction p < .001; OR = 2.9, 95% CI: 1.3, 6.6) but were not associated with water intake. CONCLUSION Negative perceptions of tap water and water fountains among youth are common and should be considered in efforts to provide water in schools. PMID:24443781
Onufrak, Stephen J; Park, Sohyun; Sharkey, Joseph R; Merlo, Caitlin; Dean, Wesley R; Sherry, Bettylou
2014-03-01
Little is known regarding youth perceptions of tap water and school water fountains and how these relate to water and sugar-sweetened beverage (SSB) intake. We used national 2010 YouthStyles data to assess perceptions of tap water and school water fountains and associations with water and SSB intake. Nearly 1 in 5 participants disagreed their tap water was safe and nearly 2 in 5 disagreed school water fountains were clean and safe. Perceived tap water risk was more prevalent among non-Hispanic (NH) Blacks (26.4%) and Hispanics (28.3%) compared with NH Whites (14.7%, p < .001) and more prevalent among lower-income youth. Negative water fountain perceptions were more common among high school-aged youth. Perceived tap water risk was not associated with SSB intake (odds ratio [OR] = 1.0, 95% confidence interval [CI]: 0.6, 1.5) or water intake (OR = 1.4, 95% CI: 0.9, 2.1). Negative water fountain perceptions were associated with SSB intake only among Hispanics (race/ethnicity interaction p < .001; OR = 2.9, 95% CI: 1.3, 6.6) but were not associated with water intake. Negative perceptions of tap water and water fountains among youth are common and should be considered in efforts to provide water in schools. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.
Whelton, Andrew J; McMillan, LaKia; Connell, Matt; Kelley, Keven M; Gill, Jeff P; White, Kevin D; Gupta, Rahul; Dey, Rajarshi; Novy, Caroline
2015-01-20
During January 2014, an industrial solvent contaminated West Virginia’s Elk River and 15% of the state population’s tap water. A rapid in-home survey and water testing was conducted 2 weeks following the spill to understand resident perceptions, tap water chemical levels, and premise plumbing flushing effectiveness. Water odors were detected in all 10 homes sampled before and after premise plumbing flushing. Survey and medical data indicated flushing caused adverse health impacts. Bench-scale experiments and physiochemical property predictions showed flushing promoted chemical volatilization, and contaminants did not appreciably sorb into cross-linked polyethylene (PEX) pipe. Flushing reduced tap water 4-methylcyclohexanemethanol (4-MCHM) concentrations within some but not all homes. 4-MCHM was detected at unflushed (<10 to 420 μg/L) and flushed plumbing systems (<10 to 96 μg/L) and sometimes concentrations differed among faucets within each home. All waters contained less 4-MCHM than the 1000 μg/L Centers for Disease Control drinking water limit, but one home exceeded the 120 μg/L drinking water limit established by independent toxicologists. Nearly all households refused to resume water use activities after flushing because of water safety concerns. Science based flushing protocols should be developed to expedite recovery, minimize health impacts, and reduce concentrations in homes when future events occur.
What's Wrong with the Tap? Examining Perceptions of Tap Water and Bottled Water at Purdue University
NASA Astrophysics Data System (ADS)
Saylor, Amber; Prokopy, Linda Stalker; Amberg, Shannon
2011-09-01
The environmental impacts of bottled water prompted us to explore drinking water choices at Purdue University, located in West Lafayette, IN. A random sample of 2,045 Purdue University students, staff, and faculty was invited to participate in an online survey. The survey assessed current behaviors as well as perceived barriers and benefits to drinking tap water versus bottled water. 677 surveys were completed for a response rate of 33.1%. We then conducted qualitative interviews with a purposive sample of university undergraduates ( n = 21) to obtain contextual insights into the survey results and the beliefs of individuals with a variety of drinking water preferences. This study revealed that women drink disproportionately more bottled water then men while undergraduate students drink more than graduate students, staff and faculty. The study also uncovered a widespread belief that recycling eliminates the environmental impacts of bottled water. Important barriers to drinking tap water at Purdue include: perceived risks from tap water and the perceived safety of bottled water, preferring the taste of bottled water, and the convenience of drinking bottled water. The qualitative interviews revealed that drinking water choices can be influenced by several factors—especially whether individuals trust tap water to be clean—but involve varying levels of complexity. The implications of these results for social marketing strategies to promote tap water are discussed.
Saylor, Amber; Prokopy, Linda Stalker; Amberg, Shannon
2011-09-01
The environmental impacts of bottled water prompted us to explore drinking water choices at Purdue University, located in West Lafayette, IN. A random sample of 2,045 Purdue University students, staff, and faculty was invited to participate in an online survey. The survey assessed current behaviors as well as perceived barriers and benefits to drinking tap water versus bottled water. 677 surveys were completed for a response rate of 33.1%. We then conducted qualitative interviews with a purposive sample of university undergraduates (n = 21) to obtain contextual insights into the survey results and the beliefs of individuals with a variety of drinking water preferences. This study revealed that women drink disproportionately more bottled water then men while undergraduate students drink more than graduate students, staff and faculty. The study also uncovered a widespread belief that recycling eliminates the environmental impacts of bottled water. Important barriers to drinking tap water at Purdue include: perceived risks from tap water and the perceived safety of bottled water, preferring the taste of bottled water, and the convenience of drinking bottled water. The qualitative interviews revealed that drinking water choices can be influenced by several factors-especially whether individuals trust tap water to be clean-but involve varying levels of complexity. The implications of these results for social marketing strategies to promote tap water are discussed.
Tagami, K; Uchida, S
2011-08-01
Iodine-131 concentrations in tap water higher than 100 BqL(-1) were reported by several local governments in Japan following the Fukushima Daiichi Nuclear Power Plant accident. Some individuals in the emergency-response community recommended the boiling of tap water to remove iodine-131. However, the tap water boiling tests in this study showed no iodine-131 loss from the tap water with either short-term boiling (1-10 min) or prolonged boiling (up to 30 min) resulting in up to 3-fold volume reductions. In this situation, boiling was shown to be not effective in removing iodine-131 from tap water; indeed even higher concentrations may result from the liquid-volume reduction accompanying this process. Copyright © 2011 Elsevier Ltd. All rights reserved.
Dupont, Diane; Waldner, Cheryl; Bharadwaj, Lalita; Plummer, Ryan; Carter, Blair; Cave, Kate; Zagozewski, Rebecca
2014-01-01
The relationship between tap water and health has been a topic of public concern and calls for better management in Canada since well-publicized contamination events in two provinces (Ontario and Saskatchewan) in 2000–2001. This study reports the perspectives on health risks from tap water and corresponding use of, and spending on, bottled water in a number of different communities in Canada. In 2009–2010, four First Nations communities (three from Ontario and one from Saskatchewan) and a geographically diverse sample of non-First Nations Canadians were surveyed about their beliefs concerning health risks from tap water and their spending practices for bottled water as a substitute. Responses to five identical questions were examined, revealing that survey respondents from Ontario First Nations communities were more likely than non-First Nations Canadians to believe bottled water is safer than tap water (OR 1.6); more likely to report someone became ill from tap water (OR 3.6); more likely to express water and health concerns related to tap water consumption (OR 2.4); and more likely to spend more on bottled water (OR 4.9). On the other hand, participants from one Saskatchewan First Nations community were less likely than non-First Nations Canadians to believe that someone had become ill from drinking tap water (OR 3.8), less likely to believe bottled water is safer than tap (OR 2.0), and less likely to have health concerns with tap water (OR 1.5). These differences, however, did not translate into differences in the likelihood of high bottled water expenditures or being a 100% bottled water consumer. The paper discusses how the differences observed may be related to water supply and regulation, trust, perceived control, cultural background, location, and past experience. PMID:24886757
Stereotypes for lever-tap operation.
Chan, Alan H S; Tsang, Steve N H; Hoffmann, Errol R
2016-04-15
Lever-operated taps have become more popular and are commonly used in operating theatres, food preparation areas and where users have poor strength; however, there is very little data available for user expectations on tap operation. Thus, an experiment on dual lever-operated water tap (faucets) was conducted with the aim of for providing information for improved design. This study aims to compare different lever-tap designs and their stereotypes adopted by the end-user to operate them also to verify the stereotypes for increasing or decreasing the water flow. 240 participants were requested to rotate the lever tap to indicate direction for increasing and decreasing water flow with simulated hardware, using actual taps placed at the top of a simulated washbasin. Nine initial positions of the lever were used for increasing and decreasing flows, ranging from the ends of both levers facing outward from the bowl center to the ends of both levers facing inward. All levers operated in the horizontal plane. Strong stereotypes (greater than 80%) for several initial lever orientations were found for increasing water flow, especially when the initial lever end positions were facing outwards. However, for different initial positions at which participants were told that the water was flowing and the flow was to be decreased, no strong stereotypes existed. The stereotypes for increasing water flow of dual-lever taps were strong, whereas those for decreasing water flow were weak and hence the stereotype reversibility was also weak. In terms of user expectations, lever taps do not show any great advantage over cross-taps in terms of operator expectations for increasing and decreasing water flow.
Observation of Isotope Ratios (δ2H, δ18O, 87Sr/86Sr) of Tap Water in Urban Environments
NASA Astrophysics Data System (ADS)
Mancuso, C. J.; Tipple, B. J.; Ehleringer, J. R.
2014-12-01
Urban environments are centers for rapidly growing populations. In order to meet the culinary water needs of these areas, municipal water departments use water from multiple locations and/or sources, often piped differentially to different locations within a municipality. This practice creates isotopically distinct locations within an urban area and therefore provides insight to urban water management practices. In our study we selected urban locations in the Salt Lake Valley, UT (SLV) and San Francisco Bay Area, CA (SFB) where we hypothesized geographically distinct water isotopic ratio differences existed. Within the SLV, municipal waters come from the same mountainous region, but are derived from different geologically distinct watersheds. In contrast, SFB waters are derived from regionally distinct water sources. We hypothesized that the isotope ratios of tap waters would differ based upon known municipal sources. To test this, tap water samples were collected throughout the urban regions in SLV and SFB and analyzed for δ2H, δ18O and 87Sr/86Sr isotope ratios. Seasonal collections were also made to assess if isotope ratios differed throughout the year. Within SLV and SFB, different regions were characterized by distinct paired δ18O and 87Sr/86Sr values. These different realms also agreed with known differences in municipal water supplies within the general geographic region. Waters from different cities within Marin County showed isotopic differences, consistent with water derived from different local reservoirs. Seasonal variation was observed in paired δ18O and 87Sr/86Sr values of tap water for some locations within SLV and SFB, indicating management decisions to shift from one water source to another depending on demand and available resources. Our study revealed that the δ18O and 87Sr/86Sr values of tap waters in an urban region can exhibit significant differences despite close spatial proximity if districts differ in their use of local versus transported waters.
Stable isotope ratios of tap water in the contiguous United States
NASA Astrophysics Data System (ADS)
Bowen, Gabriel J.; Ehleringer, James R.; Chesson, Lesley A.; Stange, Erik; Cerling, Thure E.
2007-03-01
Understanding links between water consumers and climatological (precipitation) sources is essential for developing strategies to ensure the long-term sustainability of water supplies. In pursing this understanding a need exists for tools to study and monitor complex human-hydrological systems that involve high levels of spatial connectivity and supply problems that are regional, rather than local, in nature. Here we report the first national-level survey of stable isotope ratios in tap water, including spatially and temporally explicit samples from a large number of cities and towns across the contiguous United States. We show that intra-annual ranges of tap water isotope ratios are relatively small (e.g., <10‰ for δ2H) at most sites. In contrast, spatial variation in tap water isotope ratios is very large, spanning ranges of 163‰ for δ2H and 23.6‰ for δ18O. The spatial distribution of tap water isotope ratios at the national level is similar to that of stable isotope ratios of precipitation. At the regional level, however, pervasive differences between tap water and precipitation isotope ratios can be attributed to hydrological factors in the water source to consumer chain. These patterns highlight the potential for monitoring of tap water isotope ratios to contribute to the study of regional water supply stability and provide warning signals for impending water resource changes. We present the first published maps of predicted tap water isotope ratios for the contiguous United States, which will be useful in guiding future research on human-hydrological systems and as a tool for applied forensics and traceability studies.
Bencardino, Daniela; Vitali, Luca Agostino; Petrelli, Dezemona
2018-01-01
The aim of this study was to assess the microbiological quality of ready-to-eat (RTE) iceberg lettuce. Our investigation was based on the consumption tendency of university students considered a target market for this product. A total of 78 RTE samples were collected from chain supermarkets and analysed for the enumeration of aerobic mesophilic count (AMC), Escherichia coli and the detection of Salmonella spp. and Listeria monocytogenes. All samples were negative for the presence of pathogens. The mean value of AMC at the beginning, in the middle and after the expiration date was: 6.88, 8.51 and 8.72 log CFU g-1, respectively. The same investigation was performed on 12 samples of fresh iceberg lettuce samples. No pathogens were found and the mean value of AMC was lower than the RTE category (5.73 log CFU g-1; P<0.05). The effectiveness of 5 washing methods was determined on 15 samples of both fresh and RTE iceberg lettuce. Samples were washed for 15’ and 30’ in tap water (500 mL), tap water with NaCl (4 g/500 mL), tap water with bicarbonate (8 g/500 mL), tap water with vinegar (10 mL/500 mL) and tap water with chlorine-based disinfectant (10 mL/500 mL). A significant bacterial load reduction was recorded for vinegar and disinfectant after 30’ and 15’, respectively. Overall, these results showed that RTE iceberg lettuce is more contaminated than the fresh product. Also, the consumption in the first few days of packaging and after washing with disinfectants reduces the risk for health consumers. PMID:29732325
Drinking of tap water is smart, but how do it better? - A tap water quality research
NASA Astrophysics Data System (ADS)
Mika, Anna; Sekuła, Klaudia; Dendys, Marta; Ptaszek, Weronika; Postawa, Adam
2018-02-01
Drinking tap water has recently become popular. It is a way to fight with the tons of garbage (disposable, plastic bottles). However, many people are afraid of water quality. The research was performed in December 2015 in Krakow, during one week. 56 samples were collected. The samples were taken in different times of the day and in the two types of building (old one with installation from the 80s and new one with installation built in past few years). Samples were taken by two qualified operators. The first sample was collected at the morning at 6 a.m., before anyone uses the tap. The second one after the tap was flushed and then the third one after 30 minutes stagnation. At the evening was taken one sample (after using the tap all day).The aim of the research was to check the quality of drinking water in the end-user. The results show that quality of tap water in Krakow is good, also in the end-user, but the concentration of chemical elements are changing during the flushing and using of the tap.
Martinez, Yves; Merbahi, Nofel; Eichwald, Olivier; Dunand, Christophe
2018-01-01
Two plasma devices at atmospheric pressure (air dielectric barrier discharge and helium plasma jet) have been used to study the early germination of Arabidopsis thaliana seeds during the first days. Then, plasma activated waters are used during the later stage of plant development and growth until 42 days. The effects on both testa and endospserm ruptures during the germination stage are significant in the case of air plasma due to its higher energy and efficiency of producing reactive oxygen species than the case of helium plasma. The latter has shown distinct effects only for testa rupture. Analysis of germination stimulations are based on specific stainings for reactive oxygen species production, peroxidase activity and also membrane permeability tests. Furthermore, scanning electron microscopy (SEM) has shown a smoother seed surface for air plasma treated seeds that can explain the plasma induced-germination. During the growth stage, plants were watered using 4 kinds of water (tap and deionized waters activated or not by the low temperature plasma jet). With regards to other water kinds, the characterization of the tap water has shown a larger conductivity, acidity and concentration of reactive nitrogen and oxygen species. Only the tap water activated by the plasma jet has shown a significant effect on the plant growth. This effect could be correlated to reactive nitrogen species such as nitrite/nitrate species present in plasma activated tap water. PMID:29630641
Analysis of organophosphate hydraulic fluids in U.S. Air force base soils
David; Seiber
1999-04-01
Tri-aryl and tri-alkyl organophosphates (TAPs) have been used extensively as flame-retardant hydraulic fluids and fluid additives in commercial and military aircraft. Up to 80% of the consumption of these fluids has been estimated to be lost to unrecovered leakage. Tri-aryl phosphate components of these fluids are resistant to volatilization and solubilization in water, thus, their primary environmental fate pathway is sorption to soils. Environmental audits of military air bases generally do not include quantification of these compounds in soils. We have determined the presence and extent of TAP contamination in soil samples from several U.S. Air Force bases. Soils were collected, extracted, and analyzed using GC/FPD and GC/MS. Tricresyl phosphate was the most frequently found TAP in soil, ranging from 0.02 to 130 ppm. Other TAPs in soils included triphenyl phosphate and isopropylated triphenyl phosphate. Observations are made regarding the distribution, typical concentrations, persistence, and need for further testing of TAPs in soils at military installations. Additionally, GC and mass spectral data for these TAPs are presented, along with methods for their extraction, sample clean-up, and quantification.
ERIC Educational Resources Information Center
Onufrak, Stephen J.; Park, Sohyun; Sharkey, Joseph R.; Merlo, Caitlin; Dean, Wesley R.; Sherry, Bettylou
2014-01-01
Background: Little is known regarding youth perceptions of tap water and school water fountains and how these relate to water and sugar-sweetened beverage (SSB) intake. Methods: We used national 2010 YouthStyles data to assess perceptions of tap water and school water fountains and associations with water and SSB intake. Results: Nearly 1 in 5…
NASA Astrophysics Data System (ADS)
Adiwijaya; Hamada, H.; Sagawa, Y.; Yamamoto, D.
2017-11-01
Generally, in the concrete industry, several billion tons of fresh water are annually used for mixing water, curing water and cleaning water. Nevertheless, the utilization of seawater in the concrete industry is prohibited, because it increases the risk of corrosion of steel bars in concrete. This study presents strength characteristics and porosity of seawater mixed concrete and tap water mixed concrete incorporating Ground Granulated Blast-Furnace Slag (GGBS) with water-binder ratio (W/B) of 40%, 50% and 60%. The influence of seawater mixing, GGBS and curing conditions such as tap water curing (TC), seawater curing (SC) and air curing (AC) on the strength and porosity of concrete were evaluated. Based on investigation result, it was shown that there is no significant influence of seawater mixing in improving strength of GGBS concrete up to 365 days in TC and SC. Effectiveness of seawater-mixing on strength enhancement of GGBS concrete is larger in air curing than in water curing. Porosity of seawater-mixed concrete is decreased compared to tap water-mixed concrete in all curing conditions.
Gruber, Joshua S.; Colford, John M.
2014-01-01
Background: Water distribution systems are vulnerable to performance deficiencies that can cause (re)contamination of treated water and plausibly lead to increased risk of gastrointestinal illness (GII) in consumers. Objectives: It is well established that large system disruptions in piped water networks can cause GII outbreaks. We hypothesized that routine network problems can also contribute to background levels of waterborne illness and conducted a systematic review and meta-analysis to assess the impact of distribution system deficiencies on endemic GII. Methods: We reviewed published studies that compared direct tap water consumption to consumption of tap water re-treated at the point of use (POU) and studies of specific system deficiencies such as breach of physical or hydraulic pipe integrity and lack of disinfectant residual. Results: In settings with network malfunction, consumers of tap water versus POU-treated water had increased GII [incidence density ratio (IDR) = 1.34; 95% CI: 1.00, 1.79]. The subset of nonblinded studies showed a significant association between GII and tap water versus POU-treated water consumption (IDR = 1.52; 95% CI: 1.05, 2.20), but there was no association based on studies that blinded participants to their POU water treatment status (IDR = 0.98; 95% CI: 0.90, 1.08). Among studies focusing on specific network deficiencies, GII was associated with temporary water outages (relative risk = 3.26; 95% CI: 1.48, 7.19) as well as chronic outages in intermittently operated distribution systems (odds ratio = 1.61; 95% CI: 1.26, 2.07). Conclusions: Tap water consumption is associated with GII in malfunctioning distribution networks. System deficiencies such as water outages also are associated with increased GII, suggesting a potential health risk for consumers served by piped water networks. Citation: Ercumen A, Gruber JS, Colford JM Jr. 2014. Water distribution system deficiencies and gastrointestinal illness: a systematic review and meta-analysis. Environ Health Perspect 122:651–660; http://dx.doi.org/10.1289/ehp.1306912 PMID:24659576
Tsutsumi, T; Nagata, S; Hasegawa, A; Ueno, Y
2000-07-01
Trace amounts of microcystins (MCs) in drinking water should be monitored because of their potential hazard for human health as an environmental tumor promoter. We describe here a new clean-up tool with immunoaffinity column (IAC) for determination of trace amounts of MCs (from pg to microg/litre) in tap water. The water samples were concentrated with IAC clean-up and MCs levels were determined by HPLC with UV detection or enzyme-linked immunosorbent assay (ELISA). In the combination with HPLC analysis, mean recovery of microcystin-LR (MCLR),-RR and-YR spiked to tap water were 91.8%, 77.3% and 86.4%, respectively, in the range 2.5-100 microg/litre. The chromatogram of MCs-spiked tap water sample cleaned up with IAC showed effective elimination of the impurities compared to that with octadecyl silanized cartridge, which had been cleaned up with a conventional method. Also, in the combination with highly sensitive ELISA, mean recovery of MCLR spiked to tap water was 80% in the range 0.1-1000 ng/litre. The combined methods developed here can detect pg to microg/litre of MCs in tap water. The overall results indicated that IAC will be suitable as a clean-up tool for trace amounts of MCs in tap water.
NASA Astrophysics Data System (ADS)
Alameddine, Ibrahim; Jawhari, Gheeda; El-Fadel, Mutasem
2017-04-01
Perceptions developed by consumers regarding the quality of water reaching their household can affect the ultimate use of the water. This study identified key factors influencing consumers' perception of water quality in a highly urbanized coastal city, experiencing chronic water shortages, overexploitation of groundwater, and accelerated saltwater intrusion. Household surveys were administered to residents to capture views and perceptions of consumed water. Concomitantly, groundwater and tap water samples were collected and analyzed at each residence for comparison with perceptions. People's rating of groundwater quality was found to correlate to the measured water quality both in the dry and wet seasons. In contrast, perceptions regarding the water quality of the public water supply network did not show any correlation with the measured tap water quality indicators. Logistic regression models developed to predict perception based on salient variables indicated that age, apartment ownership, and levels of total dissolved solids play a significant role in shaping perceptions regarding groundwater quality. Perceptions concerning the water quality of the public water supply network appeared to be independent of the measured total dissolved solids levels at the tap but correlated to those measured in the wells. The study highlights misconceptions that can arise as a result of uncontrolled cross-connections of groundwater to the public supply network water and the development of misaligned perceptions based on prior consumption patterns, water shortages, and a rapidly salinizing groundwater aquifer.
Alameddine, Ibrahim; Jawhari, Gheeda; El-Fadel, Mutasem
2017-04-01
Perceptions developed by consumers regarding the quality of water reaching their household can affect the ultimate use of the water. This study identified key factors influencing consumers' perception of water quality in a highly urbanized coastal city, experiencing chronic water shortages, overexploitation of groundwater, and accelerated saltwater intrusion. Household surveys were administered to residents to capture views and perceptions of consumed water. Concomitantly, groundwater and tap water samples were collected and analyzed at each residence for comparison with perceptions. People's rating of groundwater quality was found to correlate to the measured water quality both in the dry and wet seasons. In contrast, perceptions regarding the water quality of the public water supply network did not show any correlation with the measured tap water quality indicators. Logistic regression models developed to predict perception based on salient variables indicated that age, apartment ownership, and levels of total dissolved solids play a significant role in shaping perceptions regarding groundwater quality. Perceptions concerning the water quality of the public water supply network appeared to be independent of the measured total dissolved solids levels at the tap but correlated to those measured in the wells. The study highlights misconceptions that can arise as a result of uncontrolled cross-connections of groundwater to the public supply network water and the development of misaligned perceptions based on prior consumption patterns, water shortages, and a rapidly salinizing groundwater aquifer.
Bottled Water Mania: Americas Misguided Infatuation with Bottled Water over Tap Water
2010-05-01
AU/ACSC/BROWN, S/AY10 AIR COMMAND AND STAFF COLLEGE AIR UNIVERSITY Bottled Water Mania: America’s Misguided...Infatuation with Bottled Water over Tap Water by Seiho P. Brown, LCDR, U.S. Navy A Research Report Submitted to the Faculty In...iii Abstract The purpose of this paper is to analyze the tendency for American people to drink bottled water over tap water even though it costs
Seenama, Chakkraphong; Tachasirinugune, Peenithi; Jintanothaitavorn, Duangporn; Kachintorn, Kanchana; Thamlikitkul, Visanu
2013-02-01
To determine the effectiveness of Virusolve+ disinfectant wipes and PAL disinfectant wipes for decontamination of inoculated bacteria on patients' environmental and medical equipment surfaces at Siriraj Hospital. Tryptic soy broths containing MRSA and XDR A. baumannii were painted onto the surfaces of patient's stainless steel bed rail, patient's fiber footboard, control panel of infusion pump machine and control panel of respirator. The contaminated surfaces were cleaned by either tap water, tap water containing detergent, Virusolve+ disinfectant wipes or PAL disinfectant wipes. The surfaces without any cleaning procedures served as the control surface. The contaminated surfaces cleaned with the aforementioned procedures and control surfaces were swabbed with cotton swabs. The swabs were streaked on agar plates to determine the presence of MRSA and XDR A. baumannii. MRSA and XDR A. baumannii were recovered from all control surfaces. All surfaces cleaned with tap water or tap water containing detergent revealed presence of both MRSA and XDR A. baumannii. However the amounts of bacteria on the surfaces cleaned with tap water containing detergent were less than those cleaned with tap water alone. All surfaces cleaned with PAL disinfectant wipes also revealed presence of both MRSA and XDR A. baumannii. However the amounts of bacteria on the surfaces cleaned with PAL disinfectant wipes were less than those cleaned with tap water containing detergent. No bacteria were recovered from all surfaces cleaned with Virusolve+ disinfectant wipes. Virusolve+ disinfectant wipes were more effective than tap water; tap water containing detergent and PAL disinfectant wipes for decontamination of bacteria inoculated on patients environmental and medical equipment surfaces at Siriraj Hospital.
Fluctuations of ground-water levels in Lee County, Florida, in 1975 water year
O'Donnell, T. H.
1977-01-01
During the 1975 water year, rainfall was about average at Page Field, Florida, and from 20-25 percent below average at Lehigh Acres and Sanibel Island. Water levels were monitored in 57 observation wells in Lee County, Florida. Of the 23 wells that tap the water-table aquifer, one record high and 5 record low water levels were established. Record low water levels were established in 5 of 20 wells that tap the sandstone aquifer and in 1 of 10 wells that tap the upper Hawthorn aquifer. A record high water level was established in 1 of 3 wells that tap the lower Hawthorn aquifer. (Woodard-USGS)
Sociodemographic Characteristics and Beverage Intake of Children Who Drink Tap Water
Patel, Anisha I.; Shapiro, Daniel J.; Wang, Y. Claire; Cabana, Michael D.
2015-01-01
Background Tap water provides a calorie-free, no-cost, environmentally friendly beverage option, yet only some youth drink it. Purpose To examine sociodemographic characteristics, weight status, and beverage intake of those aged 1–19 years who drink tap water. Methods National Health and Nutrition Examination Survey data (2005–2010) were used to examine factors associated with tap water consumption. A comparison was made of beverage intake among tap water consumers and nonconsumers, by age, race/ethnicity, and income. Results Tap water consumption was more prevalent among school-aged children (OR=1.85, 95% CI=1.47, 2.33, for those aged 6–11 years; OR=1.85, 95% CI=1.32, 2.59, for those aged 12–19 years) as compared to those aged 1–2 years. Tap water intake was less prevalent among girls/women (OR=0.76, 95% CI=0.64, 0.89); Mexican Americans (OR=0.32, 95% CI=0.23, 0.45); non-Hispanic blacks (OR=0.48, 95% CI=0.34, 0.67); and others (OR=0.50, 95% CI=0.36, 0.68) as compared to whites; Spanish speakers (OR=0.72, 95% CI=0.55, 0.95); and among referents with a lower than Grade-9 education (OR=0.52, 95% CI=0.31, 0.88); Grade 9–11 education (OR=0.50, 95% CI=0.32, 0.77); and high school/General Educational Development test completion (OR=0.50, 95% CI=0.33, 0.76), as compared to college graduates. Tap water consumers drank more fluid (52.5 vs 48.0 ounces, p<0.01); more plain water (20.1 vs 15.2 ounces, p<0.01); and less juice (3.6 vs 5.2 ounces, p<0.01) than nonconsumers. Conclusions One in six children/adolescents does not drink tap water, and this finding is more pronounced among minorities. Sociodemographic disparities in tap water consumption may contribute to disparities in health outcomes. Improvements in drinking water infrastructure and culturally relevant promotion may help to address these issues. PMID:23790991
Drinking water quality in a Mexico city university community: perception and preferences.
Espinosa-García, Ana C; Díaz-Ávalos, Carlos; González-Villarreal, Fernando J; Val-Segura, Rafael; Malvaez-Orozco, Velvet; Mazari-Hiriart, Marisa
2015-03-01
A transversal study was conducted at the University City campus of the National Autonomous University of Mexico (UNAM) in Mexico City, with the goal of estimating the university community preference for drinking either tap water or bottled water and the reasons for their selection. A representative sample of three university community subpopulations (students, workers/administrative staff, and academic personnel) were interviewed with respect to their water consumption habits. The results showed that 75% of the university community drinks only bottled water and that the consumption of tap water is low. The interviewees responded that the main reason for this preference is the organoleptic features of tap water independent of quality. In general, the participants in this study do not trust the quality of the tap water, which could be caused by the facilities that distribute bottled water encouraging a general disinterest in learning about the origin and management of the tap water that is distributed on campus.
The mineral content of tap water in United States households
USDA-ARS?s Scientific Manuscript database
The composition of tap water contributes to dietary intake of minerals. The USDA’s Nutrient Data Laboratory (NDL) conducted a study of the mineral content of residential tap water, to generate current data for the USDA National Nutrient Database. Sodium, potassium, calcium, magnesium, iron, copper...
Longitudinal and Source-to-Tap New Orleans, LA, U.S.A. Drinking Water Microbiology.
Hull, Natalie M; Holinger, Eric P; Ross, Kimberly A; Robertson, Charles E; Harris, J Kirk; Stevens, Mark J; Pace, Norman R
2017-04-18
The two municipal drinking water systems of New Orleans, LA, U.S.A. were sampled to compare the microbiology of independent systems that treat the same surface water from the Mississippi River. To better understand temporal trends and sources of microbiology delivered to taps, these treatment plants and distribution systems were subjected to source-to-tap sampling over four years. Both plants employ traditional treatment by chloramination, applied during or after settling, followed by filtration before distribution in a warm, low water age system. Longitudinal samples indicated microbiology to have stability both spatially and temporally, and between treatment plants and distribution systems. Disinfection had the greatest impact on microbial composition, which was further refined by filtration and influenced by distribution and premise plumbing. Actinobacteria spp. exhibited trends with treatment. In particular, Mycobacterium spp., very low in finished waters, occurred idiosyncratically at high levels in some tap waters, indicating distribution and/or premise plumbing as main contributors of mycobacteria. Legionella spp., another genus containing potential opportunistic pathogens, also occurred ubiquitously. Source water microbiology was most divergent from tap water, and each step of treatment brought samples more closely similar to tap waters.
Disparity in disinfection byproducts concentration between hot and cold tap water.
Liu, Boning; Reckhow, David A
2015-03-01
The quality of water entering a distribution system may differ substantially from the quality at the point of exposure to the consumer. This study investigated temporal variations in the levels of regulated and non-regulated disinfection byproducts (DBPs) in cold and hot tap water in a home on a medium-sized municipal water system. In addition, samples were collected directly from the water plant with some being held in accordance with a simulated distribution system (SDS) test protocol. The location for this work was a system in western Massachusetts, USA that uses free chlorine as a final disinfectant. Very little short term variability of DBPs at the point of entry (POE) was observed. The concentration of DBPs in the time-variable SDS test was similar to concentrations in the cold water tap. For most DBPs, the concentrations continued to increase as the cold water tap sample was held for the time-variable SDS incubation period. However, the impact of heating on DBP levels was compound specific. For example, the concentrations of trihalomethanes (THMs), dichloroacetic acid (DCAA) and chloropicrin (CP) were substantially higher in the hot water tap than in the cold water time-variable SDS samples. In contrast, the concentration of trichloroacetic acid (TCAA) was lower in the heated hot tap water, but about equal to that observed in the cold tap water. The situation was more pronounced for dichloroacetonitrile (DCAN), bromodichloroacetic acid (BDCAA), bromochloroacetic acid (BCAA) and 1,1,1-trichloropropanone (TCP), which all showed lower concentrations in the hot water then in either of the cold water samples (instantaneous or time-variable SDS). The latter was viewed as a clear indication of thermally-induced decomposition. The ratio of unknown total organic halide (UTOX) to TOX was substantially lower in the hot tap water as the THM to TOX ratio became correspondingly larger. The results of this study show that DBP exposure in the home is not well represented by concentrations measured in cold water taps where most compliance monitoring is done. Copyright © 2014 Elsevier Ltd. All rights reserved.
Leung, Ho Wing; Jin, Ling; Wei, Si; Tsui, Mirabelle Mei Po; Zhou, Bingsheng; Jiao, Liping; Cheung, Pak Chuen; Chun, Yiu Kan; Murphy, Margaret Burkhardt; Lam, Paul Kwan Sing
2013-07-01
Pharmaceuticals are known to contaminate tap water worldwide, but the relevant human health risks have not been assessed in China. We monitored 32 pharmaceuticals in Chinese tap water and evaluated the life-long human health risks of exposure in order to provide information for future prioritization and risk management. We analyzed samples (n = 113) from 13 cities and compared detected concentrations with existing or newly-derived safety levels for assessing risk quotients (RQs) at different life stages, excluding the prenatal stage. We detected 17 pharmaceuticals in 89% of samples, with most detectable concentrations (92%) at < 50 ng/L. Caffeine (median-maximum, nanograms per liter: 24.4-564), metronidazole (1.8-19.3), salicylic acid (16.6-41.2), clofibric acid (1.2-3.3), carbamazepine (1.3-6.7), and dimetridazole (6.9-14.7) were found in ≥ 20% of samples. Cities within the Yangtze River region and Guangzhou were regarded as contamination hot spots because of elevated levels and frequent positive detections. Of the 17 pharmaceuticals detected, 13 showed very low risk levels, but 4 (i.e., dimetridazole, thiamphenicol, sulfamethazine, and clarithromycin) were found to have at least one life-stage RQ ≥ 0.01, especially for the infant and child life stages, and should be considered of high priority for management. We propose an indicator-based monitoring framework for providing information for source identification, water treatment effectiveness, and water safety management in China. Chinese tap water is an additional route of human exposure to pharmaceuticals, particularly for dimetridazole, although the risk to human health is low based on current toxicity data. Pharmaceutical detection and application of the proposed monitoring framework can be used for water source protection and risk management in China and elsewhere.
Cope, Jennifer R.; Ratard, Raoult C.; Hill, Vincent R.; Sokol, Theresa; Causey, Jonathan Jake; Yoder, Jonathan S.; Mirani, Gayatri; Mull, Bonnie; Mukerjee, Kimberly A.; Narayanan, Jothikumar; Doucet, Meggie; Qvarnstrom, Yvonne; Poole, Charla N.; Akingbola, Olugbenga A.; Ritter, Jana; Xiong, Zhenggang; da Silva, Alexandre; Roellig, Dawn; Van Dyke, Russell; Stern, Harlan; Xiao, Lihua; Beach, Michael J.
2015-01-01
Background Naegleria fowleri is a climate-sensitive, thermophilic ameba found in warm, freshwater lakes and rivers. Primary amebic meningoencephalitis (PAM), which is almost universally fatal, occurs when N. fowleri–containing water enters the nose, typically during swimming, and N. fowleri migrates to the brain via the olfactory nerve. In August 2013, a 4-year-old child died of meningoencephalitis of unknown etiology in a Louisiana hospital. Methods Clinical and environmental testing and a case investigation were initiated to determine the cause of death and to identify potential exposures. Results Based on testing of CSF and brain specimens, the child was diagnosed with PAM. His only reported water exposure was tap water; in particular, tap water that was used to supply water to a lawn water slide on which the child had played extensively prior to becoming ill. Water samples were collected from both the home and the water distribution system that supplied the home and tested; N. fowleri were identified in water samples from both the home and the water distribution system. Conclusions This case is the first reported PAM death associated with culturable N. fowleri in tap water from a U.S. treated drinking water system. This case occurred in the context of an expanding geographic range for PAM beyond southern tier states with recent case reports from Minnesota, Kansas, and Indiana. This case also highlights the role of adequate disinfection throughout drinking water distribution systems and the importance of maintaining vigilance when operating drinking water systems using source waters with elevated temperatures. PMID:25595746
Cope, Jennifer R; Ratard, Raoult C; Hill, Vincent R; Sokol, Theresa; Causey, Jonathan Jake; Yoder, Jonathan S; Mirani, Gayatri; Mull, Bonnie; Mukerjee, Kimberly A; Narayanan, Jothikumar; Doucet, Meggie; Qvarnstrom, Yvonne; Poole, Charla N; Akingbola, Olugbenga A; Ritter, Jana M; Xiong, Zhenggang; da Silva, Alexandre J; Roellig, Dawn; Van Dyke, Russell B; Stern, Harlan; Xiao, Lihua; Beach, Michael J
2015-04-15
Naegleria fowleri is a climate-sensitive, thermophilic ameba found in warm, freshwater lakes and rivers. Primary amebic meningoencephalitis (PAM), which is almost universally fatal, occurs when N. fowleri-containing water enters the nose, typically during swimming, and migrates to the brain via the olfactory nerve. In August 2013, a 4-year-old boy died of meningoencephalitis of unknown etiology in a Louisiana hospital. Clinical and environmental testing and a case investigation were initiated to determine the cause of death and to identify potential exposures. Based on testing of cerebrospinal fluid and brain specimens, the child was diagnosed with PAM. His only reported water exposure was tap water; in particular, tap water that was used to supply water to a lawn water slide on which the child had played extensively prior to becoming ill. Water samples were collected from both the home and the water distribution system that supplied the home and tested; N. fowleri was identified in water samples from both the home and the water distribution system. This case is the first reported PAM death associated with culturable N. fowleri in tap water from a US treated drinking water system. This case occurred in the context of an expanding geographic range for PAM beyond southern states, with recent case reports from Minnesota, Kansas, and Indiana. This case also highlights the role of adequate disinfection throughout drinking water distribution systems and the importance of maintaining vigilance when operating drinking water systems using source waters with elevated temperatures. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Rainwater harvesting in American Samoa: current practices and indicative health risks.
Kirs, Marek; Moravcik, Philip; Gyawali, Pradip; Hamilton, Kerry; Kisand, Veljo; Gurr, Ian; Shuler, Christopher; Ahmed, Warish
2017-05-01
Roof-harvested rainwater (RHRW) is an important alternative source of water that many island communities can use for drinking and other domestic purposes when groundwater and/or surface water sources are contaminated, limited, or simply not available. The aim of this pilot-scale study was to investigate current RHRW practices in American Samoa (AS) and to evaluate and compare the quality of water from common potable water sources including RHRW stored in tanks, untreated stream water, untreated municipal well water, and treated municipal tap water samples. Samples were analyzed using culture-based methods, quantitative polymerase chain reaction (qPCR), and 16S amplicon sequencing-based methods. Based on indicator bacteria (total coliform and Escherichia coli) concentrations, the quality of RHRW was slightly lower than well and chlorinated tap water but exceeded that of untreated stream water. Although no Giardia or Leptospira spp. were detected in any of the RHRW samples, 86% of the samples were positive for Cryptosporidium spp. All stream water samples tested positive for Cryptosporidium spp. Opportunistic pathogens (Pseudomonas aeruginosa and Mycobacterium intracellulare) were also detected in the RHRW samples (71 and 21% positive samples, respectively). Several potentially pathogenic genera of bacteria were also detected in RHRW by amplicon sequencing. Each RHRW system was characterized by distinct microbial communities, 77% of operational taxonomic units (OTUs) were detected only in a single tank, and no OTU was shared by all the tanks. Risk of water-borne illness increased in the following order: chlorinated tap water/well water < RHRW < stream water. Frequent detection of opportunistic pathogens indicates that RHRW should be treated before use. Stakeholder education on RHRW system design options as well as on importance of regular cleaning and proper management techniques could improve the quality of the RHRW in AS.
Tapping mode SPM local oxidation nanolithography with sub-10 nm resolution
NASA Astrophysics Data System (ADS)
Nishimura, S.; Ogino, T.; Takemura, Y.; Shirakashi, J.
2008-03-01
Tapping mode SPM local oxidation nanolithography with sub-10 nm resolution is investigated by optimizing the applied bias voltage (V), scanning speed (S) and the oscillation amplitude of the cantilever (A). We fabricated Si oxide wires with an average width of 9.8 nm (V = 17.5 V, S = 250 nm/s, A = 292 nm). In SPM local oxidation with tapping mode operation, it is possible to decrease the size of the water meniscus by enhancing the oscillation amplitude of cantilever. Hence, it seems that the water meniscus with sub-10 nm dimensions could be formed by precisely optimizing the oxidation conditions. Moreover, we quantitatively explain the size (width and height) of Si oxide wires with a model based on the oxidation ratio, which is defined as the oxidation time divided by the period of the cantilever oscillation. The model allows us to understand the mechanism of local oxidation in tapping mode operation with amplitude modulation. The results imply that the sub-10 nm resolution could be achieved using tapping mode SPM local oxidation technique with the optimization of the cantilever dynamics.
Into hot water head first: distribution of intentional and unintentional immersion burns.
Daria, Sonya; Sugar, Naomi F; Feldman, Kenneth W; Boos, Stephen C; Benton, Scott A; Ornstein, Amy
2004-05-01
Experience with several, previously unreported, intentional face-first immersion burns led us to evaluate the distribution of inflicted and unintentional immersion scald burns in a hospital series. (1) Authors' clinical and legal practices; (2) Burn center at regional Level 1 trauma hospital. : (1) Case series of face-first, inflicted immersion burn victims; (2) Consecutive hospitalized scald burn victims younger than 5 years old, 1/3/1996 to 3/25/2000. (1) Individual case reports; (2) Retrospective records review. Simple descriptive statistics, Fisher Exact test and t test. (1) Six cases of inflicted head and neck immersion injury are described. Four were tap water and 2 food/drink scalds. (2) 22/195 hospitalized victims had sustained immersion burns, 13 from tap water and 9 from other fluids. Six (46%) tap water immersions and no (0%) other immersions had inflicted injuries (P = 0.05). Two of the tap water immersions and one other source immersion included burning of the head and neck. Of these, one tap water immersion, but no other immersion, was inflicted. In no patients were head and neck injuries the sole or predominant site of scalding. In all, 9 children sustained inflicted scalds. Bilateral lower extremity tap water immersion scalds occurred in 100% (6/6) of abusive and 29% (2/7) of unintentional injuries (P = 0.02). Buttock and perineal injuries occurred in 67% (4/6) inflicted versus 29% (2/7) unintentional tap water immersion scalds (P = 0.28). Other fluids caused bilateral lower extremity immersion burns in 3/9 (33 %) unintentionally injured patients, but no abused children (NS). Craniofacial immersion injury, although seen by the authors in legal cases, is infrequent. It was present incidentally in one inflicted tap water burn in the consecutive hospital series. This series affirms the predominance of bilateral lower extremity burns in inflicted tap water immersions. Buttock/perineal immersions were more common with abuse than with unintentional injury.
Shi, Wei; Hu, Xinxin; Zhang, Fengxian; Hu, Guanjiu; Hao, Yingqun; Zhang, Xiaowei; Liu, Hongling; Wei, Si; Wang, Xinru; Giesy, John P; Yu, Hongxia
2012-02-07
Thyroid hormone is essential for the development of humans. However, some synthetic chemicals with thyroid disrupting potentials are detectable in drinking water. This study investigated the presence of thyroid active chemicals and their toxicity potential in drinking water from five cities in eastern China by use of an in vitro CV-1 cell-based reporter gene assay. Waters were examined from several phases of drinking water processing, including source water, finished water from waterworks, tap water, and boiled tap water. To identify the responsible compounds, concentrations and toxic equivalents of a list of phthalate esters were quantitatively determined. None of the extracts exhibited thyroid receptor (TR) agonist activity. Most of the water samples exhibited TR antagonistic activities. None of the boiled water displayed the TR antagonistic activity. Dibutyl phthalate accounted for 84.0-98.1% of the antagonist equivalents in water sources, while diisobutyl phthalate, di-n-octyl phthalate and di-2-ethylhexyl phthalate also contributed. Approximately 90% of phthalate esters and TR antagonistic activities were removable by waterworks treatment processes, including filtration, coagulation, aerobic biodegradation, chlorination, and ozonation. Boiling water effectively removed phthalate esters from tap water. Thus, this process was recommended to local residents to reduce certain potential thyroid related risks through drinking water.
A level change in mutagenicity of Japanese tap water over the past 12 yr.
Takanashi, Hirokazu; Kishida, Misako; Nakajima, Tsunenori; Ohki, Akira; Akiba, Michihiro
2011-05-01
A relative comparison study of mutagenicity in Japanese tap water was conducted for 1993 and 2005 surveys. It intended to assess the effects of advanced water treatment installations to water works, improvement of raw water quality and improvement of residual HOCl concentration controlling. Sampling points (taps) were the same in both surveys. The results of 245 samples obtained by the Ames Salmonella mutagenicity test (Ames test) were analyzed. The Ames tests were conducted by using Salmonella typhimurium TA98 and TA100 strains with and without exogenous activation (S9). With the exception of TA100-S9, the other conditions needed no discussion as a factor in the mutagenicity level change. The average mutagenicity in 1993 and 2005 under the conditions of TA100-S9 were 2600 and 1100 net revertantL(-1), respectively. This indicated that the mutagenicity level of Japanese tap water decreased during the 12-yr period. Particularly a remarkable decrease in mutagenicity was observed in the water works where the advanced water treatments were installed during the 12-yr period. The advanced water treatments were effective in decreasing the mutagenicity of tap water. Mutagenicity also decreased in the water works with conventional water treatments; the improvement of residual HOCl concentration controlling was also considered to be effective in decreasing the mutagenicity of tap water. Copyright © 2011 Elsevier Ltd. All rights reserved.
Hu, Yaxi; Lu, Xiaonan
2016-05-01
An innovative "one-step" sensor conjugating molecularly imprinted polymers and surface enhanced Raman spectroscopic-active substrate (MIPs-SERS) was investigated for simultaneous extraction and determination of melamine in tap water and milk. This sensor was fabricated by integrating silver nanoparticles (AgNPs) with MIPs synthesized by bulk polymerization of melamine (template), methacrylic acid (functional monomer), ethylene glycol dimethacrylate (cross-linking agent), and 2,2'-azobisisobutyronitrile (initiator). Static and kinetic adsorption tests validated the specific affinity of MIPs-AgNPs to melamine and the rapid adsorption equilibration rate. Principal component analysis segregated SERS spectral features of tap water and milk samples with different melamine concentrations. Partial least squares regression models correlated melamine concentrations in tap water and skim milk with SERS spectral features. The limit of detection (LOD) and limit of quantification (LOQ) of melamine in tap water were determined as 0.0019 and 0.0064 mmol/L, while the LOD and LOQ were 0.0165 and 0.055 mmol/L for the determination of melamine in skim milk. However, this sensor is not ideal to quantify melamine in tap water and skim milk. By conjugating MIPs with SERS-active substrate (that is, AgNPs), reproducibility of SERS spectral features was increased, resulting in more accurate detection. The time required to determine melamine in tap water and milk were 6 and 25 min, respectively. The low LOD, LOQ, and rapid detection confirm the potential of applying this sensor for accurate and high-throughput detection of melamine in tap water and milk. © 2016 Institute of Food Technologists®
Lesnik, René; Brettar, Ingrid; Höfle, Manfred G
2016-01-01
Water samples of the Drinking Water Supply System (DWSS) of the city of Braunschweig were analysed for its Legionella species composition using genus-specific PCR amplicons and single-strand conformation polymorphism (SSCP) fingerprint analyses based on 16S rRNA genes. These analyses comprised the whole supply chain including raw water, treatment process and large-scale storage, and a seasonal study of finished drinking water sampled monthly from cold and hot tap water. Treatment of raw water had a major impact on Legionella species by reducing their diversity and abundances. The Legionella species composition of the tap water was highly distinct from that of both source waters. In cold water, 8–14 different phylotypes of Legionella (PTLs) were observed per sample with relative abundances ranging from >1% to 53%. In hot water, L. pneumophila was present during all seasons at high relative abundances (8–40%) accompanied by 5–14 other PTLs of which 6 PTLs were in common with cold water. This thermophilic Legionella community, including L. pneumophila, was able to grow in the hot water above 50 °C. Such thermophilic Legionella populations are of general relevance for drinking water management and public health, but also for the ecology and evolution of the genus Legionella. PMID:26528838
Lesnik, René; Brettar, Ingrid; Höfle, Manfred G
2016-05-01
Water samples of the Drinking Water Supply System (DWSS) of the city of Braunschweig were analysed for its Legionella species composition using genus-specific PCR amplicons and single-strand conformation polymorphism (SSCP) fingerprint analyses based on 16S rRNA genes. These analyses comprised the whole supply chain including raw water, treatment process and large-scale storage, and a seasonal study of finished drinking water sampled monthly from cold and hot tap water. Treatment of raw water had a major impact on Legionella species by reducing their diversity and abundances. The Legionella species composition of the tap water was highly distinct from that of both source waters. In cold water, 8-14 different phylotypes of Legionella (PTLs) were observed per sample with relative abundances ranging from >1% to 53%. In hot water, L. pneumophila was present during all seasons at high relative abundances (8-40%) accompanied by 5-14 other PTLs of which 6 PTLs were in common with cold water. This thermophilic Legionella community, including L. pneumophila, was able to grow in the hot water above 50 °C. Such thermophilic Legionella populations are of general relevance for drinking water management and public health, but also for the ecology and evolution of the genus Legionella.
Comparing microbial water quality in an intermittent and continuous piped water supply.
Kumpel, Emily; Nelson, Kara L
2013-09-15
Supplying piped water intermittently is a common practice throughout the world that increases the risk of microbial contamination through multiple mechanisms. Converting an intermittent supply to a continuous supply has the potential to improve the quality of water delivered to consumers. To understand the effects of this upgrade on water quality, we tested samples from reservoirs, consumer taps, and drinking water provided by households (e.g. from storage containers) from an intermittent and continuous supply in Hubli-Dharwad, India, over one year. Water samples were tested for total coliform, Escherichia coli, turbidity, free chlorine, and combined chlorine. While water quality was similar at service reservoirs supplying the continuous and intermittent sections of the network, indicator bacteria were detected more frequently and at higher concentrations in samples from taps supplied intermittently compared to those supplied continuously (p < 0.01). Detection of E. coli was rare in continuous supply, with 0.7% of tap samples positive compared to 31.7% of intermittent water supply tap samples positive for E. coli. In samples from both continuously and intermittently supplied taps, higher concentrations of total coliform were measured after rainfall events. While source water quality declined slightly during the rainy season, only tap water from intermittent supply had significantly more indicator bacteria throughout the rainy season compared to the dry season. Drinking water samples provided by households in both continuous and intermittent supplies had higher concentrations of indicator bacteria than samples collected directly from taps. Most households with continuous supply continued to store water for drinking, resulting in re-contamination, which may reduce the benefits to water quality of converting to continuous supply. Copyright © 2013 Elsevier Ltd. All rights reserved.
Efimenko, N V; Frolkov, V K; Kozlova, V V; Kaisinova, A S; Chalaya, E N
2017-12-05
The objective of the present research was to study the influence of tap water enriched with silver nanoparticles (NP) as well as that of «Krasnoarmeysky» and «Essentuki №17» mineral waters after their single administration through the oral gavage to the rats on the metabolism of carbohydrates and lipids, the biochemical markers of the liver condition, and the endocrine profile in the healthy animals. The laboratory animals (130 male Wistar rats) were allocated to thirteen groups comprised of 10 rats each as follows: 1st group (n=10) intact animals, 2nd group (5 minutes after the administration of silver NP (n=10), 3rd group (15 minutes after the of silver NP), 4th group (60 minutes after the administration of silver NP), 5th group (n=10) (5 minutes after the introduction of the «Krasnoarmeysky» mineral water), 6th group (n=10) (15 min after the introduction of the «Krasnoarmeysky» mineral water), 7th group (n=10), (60 minutes after the introduction of the «Krasnoarmeysky» mineral water) 8th group (n=10) (5 minutes after the introduction of the «Essentuki № 17» mineral water), 9th group (n=10) (15 min after the introduction of the «Essentuki № 7» mineral water) , 10th group (n=10) (60 minutes after the introduction of the «Essentuki №17» mineral water), 11th group (n=10) (5 minutes after administration of tap water (control),12th group (n=10) (15 minutes after administration of tap water (control), and 13th (n=10) group 60 minutes after administration of tap water (control). The study has demonstrated that the tap water enriched with silver nanoparticles similar to the mineral waters caused stress reactions that are inferior to those induced by «Essentuki №17» mineral water in terms of the magnitude; however, the effect provoked by the tap water was of longer duration. Moreover, the tap water enriched with silver nanoparticles stimulates prooxidant reactions, and inhibit the activity of antioxidant protection. Silver nanoparticles appear to produce some destructive effect on the hepatocytes. The silver nanoparticles present in the tap water have a significant biological potential of their own. Moreover, their one-time action is apt to alter the biological potential of the water into which they are administered. The single intake of the tap water enriched with silver nanoparticles by the healthy laboratory animals produces the response that resembles that of the drinking mineral water.
Braeye, T; DE Schrijver, K; Wollants, E; van Ranst, M; Verhaegen, J
2015-03-01
SUMMARY On 6 December 2010 a fire in Hemiksem, Belgium, was extinguished by the fire brigade with both river water and tap water. Local physicians were asked to report all cases of gastroenteritis. We conducted a retrospective cohort study among 1000 randomly selected households. We performed a statistical and geospatial analysis. Human stool samples, tap water and river water were tested for pathogens. Of the 1185 persons living in the 528 responding households, 222 (18·7%) reported symptoms of gastroenteritis during the time period 6-13 December. Drinking tap water was significantly associated with an increased risk for gastroenteritis (relative risk 3·67, 95% confidence interval 2·86-4·70) as was place of residence. Campylobacter sp. (2/56), norovirus GI and GII (11/56), rotavirus (1/56) and Giardia lamblia (3/56) were detected in stool samples. Tap water samples tested positive for faecal indicator bacteria and protozoa. The results support the hypothesis that a point-source contamination of the tap water with river water was the cause of the multi-pathogen waterborne outbreak.
Antibacterial effect of electrolyzed water on oral bacteria.
Lee, Sung-Hoon; Choi, Bong-Kyu
2006-08-01
This study investigated the antibacterial effect of electrolyzed water on oral bacteria both in vitro and in vivo. Tap water was electrolyzed in a water vessel using platinum cell technology. The electrolyzed tap water (called Puri-water) was put in contact with five major periodontopathogens or toothbrushes contaminated with these bacteria for 30 sec. In addition, Puri-water was used as a mouthwash for 30 sec in 16 subjects and the antibacterial effect on salivary bacteria was evaluated. Puri-water significantly reduced the growth of all periodontopathogens in culture and on toothbrushes, and that of aerobic and anaerobic bacteria in saliva, when compared to the effect of tap water. It also significantly reduced mutans streptococci growing on mitis salivarius-bacitracin agar. Our results demonstrate that the electrolyzed tap water is effective as a mouthwash and for toothbrush disinfection.
Kruger, Daniel J; Kodjebacheva, Gergana D; Cupal, Suzanne
2017-08-01
After inadequate official response to community concerns over water quality following changes in Flint's municipal water supply, this study sought evidence for a relationship between water quality and community mental health. The Speak to Your Health Community Survey is a community-based participatory component of the health surveillance system in Genesee County, Michigan. This cross-sectional survey recruits participants from every residential Census Tract of the county and strives for demographic representativeness. Respondents (n=834) rated their tap water quality (taste, smell, appearance) as poor (36%), fair (18%), good (20%), very good (17%), and excellent (10%). They rated their sleep quality as poor (12%), fair (28%), good (39%), very good (18%), and excellent (4%), and had an average (SD) sleep length of 408(90) minutes. Controlling for age, sex, years of education, and whether respondents were African American and Hispanic/Latino/a, lower perceived tap water quality was associated with lower sleep quality and shorter sleep length. Results indicate that adverse health conditions related to the water crisis extend beyond lead poisoning in children and include deterioration of sleep conditions among adult residents. Copyright © 2017 National Sleep Foundation. Published by Elsevier Inc. All rights reserved.
Fluoride and bacterial content of bottled drinking water versus municipal tap water.
Mythri, H; Chandu, G N; Prashant, G M; Subba Reddy, V V
2010-01-01
Water is a divine gift. People quench their thirst without questioning the source of water. But, apprehension about contaminants in municipal water supplies along with increased fear of fluorosis made bottled drinking water as one of the important tradable commodities. The objectives of the study were to determine and compare the fluoride and bacterial contents of commercially available bottled drinking water and municipal tap water in Davangere city, Karnataka. Fifty samples of 10 categories of bottled drinking water with different batch numbers were purchased and municipal water from different sources were collected. Fluoride levels were determined by an ion-selective electrode. Water was cultured quantitatively and levels of bacteria were calculated as colony-forming units (CFUs) per milliliter. Descriptive analysis of water samples for fluoride concentration was in the range of 0.07-0.33 for bottled drinking water, Bisleri showing the highest of 0.33. A comparison of the mean values of microbial count for bottled drinking water with that of municipal tap water showed no statistically significant difference, but was more than the standard levels along with the presence of fungus and maggots. The fluoride concentration was below the optimal level for both municipal tap water and bottled drinking water. CFUs were more than the recommended level in both municipal tap water and bottled drinking water.
Ueda, Momoko; Bell, Lynne S
2017-05-01
Human geolocation is prefaced on the accuracy of the geographic precision of mapped isotopic values for drinking water. As most people live in cities, it becomes important to understand city water supplies and how the isotopic values uniquely reflect that city. This study investigated the isotopic distribution of δ 2 H and δ 18 O from sourced tap waters that were collected from across the Metro Vancouver (MV) area (n = 135). The results revealed that the isotopic values reflect their water sources with a range of 5.3‰ for δ 18 O tap and 29.3‰ for δ 2 H tap for MV. The results indicate that individual cities need higher resolution studies to determine their tap water isotopic ranges, and a good understanding of the water supply network itself for human geolocation work. With an extended high-resolution understanding of each city, human tissue may be compared with more certainty for geolocation. © 2016 American Academy of Forensic Sciences.
Ditommaso, Savina; Giacomuzzi, Monica; Ricciardi, Elisa; Zotti, Carla M
2016-02-06
Legionella spp. are ubiquitous in aquatic habitats and water distribution systems, including dental unit waterlines (DUWLs). The aim of the present study was to determine the prevalence of Legionella in DUWLs and tap water samples using PMA-qPCR and standard culture methods. The total viable counts (TVCs) of aerobic heterotrophic bacteria in the samples were also determined. Legionella spp. were detected and quantified using the modified ISO 11731 culture method. Extracted genomic DNA was analysed using the iQ-Check Quanti Legionella spp. kit, and the TVCs were determined according to the ISO protocol 6222. Legionella spp. were detected in 100% of the samples using the PMA-qPCR method, whereas these bacteria were detected in only 7% of the samples using the culture method. The number of colony forming units (CFUs) of the TVCs in the DUWL and tap water samples differed, with the bacterial load being significantly lower in the tap water samples (p-value = 0). The counts obtained were within the Italian standard range established for potable water in only 5% of the DUWL water samples and in 77% of the tap water samples. Our results show that the level of Legionella spp. contamination determined using the culture method does not reflect the true scale of the problem, and consequently we recommend testing for the presence of aerobic heterotrophic bacteria based on the assumption that Legionella spp. are components of biofilms.
Ditommaso, Savina; Giacomuzzi, Monica; Ricciardi, Elisa; Zotti, Carla M.
2016-01-01
Legionella spp. are ubiquitous in aquatic habitats and water distribution systems, including dental unit waterlines (DUWLs). The aim of the present study was to determine the prevalence of Legionella in DUWLs and tap water samples using PMA-qPCR and standard culture methods. The total viable counts (TVCs) of aerobic heterotrophic bacteria in the samples were also determined. Legionella spp. were detected and quantified using the modified ISO 11731 culture method. Extracted genomic DNA was analysed using the iQ-Check Quanti Legionella spp. kit, and the TVCs were determined according to the ISO protocol 6222. Legionella spp. were detected in 100% of the samples using the PMA-qPCR method, whereas these bacteria were detected in only 7% of the samples using the culture method. The number of colony forming units (CFUs) of the TVCs in the DUWL and tap water samples differed, with the bacterial load being significantly lower in the tap water samples (p-value = 0). The counts obtained were within the Italian standard range established for potable water in only 5% of the DUWL water samples and in 77% of the tap water samples. Our results show that the level of Legionella spp. contamination determined using the culture method does not reflect the true scale of the problem, and consequently we recommend testing for the presence of aerobic heterotrophic bacteria based on the assumption that Legionella spp. are components of biofilms. PMID:26861373
The occurrence of antibiotic resistance genes in tap water - a review
NASA Astrophysics Data System (ADS)
Siedlecka, Agata
2018-02-01
The study presents a review of the occurrence of genetic determinants of antibiotic resistance in tap water. The aim of this study was also to compare the applied methods for antibiotic resistance genes (ARGs) investigations in tap water. As the concentration of ARGs in treated, drinking water is expected to be very low and may cause problems in a standard isolation procedure, the special emphasis is placed on the applied procedures of DNA extraction and their efficiency. The study presents the first attempts to obtain DNA directly from tap water. Further efforts must be put to determine the final amount of obtained DNA and the presence of chosen ARGs among the molecules.
Nriagu, Jerome; Xi, Chuanwu; Siddique, Azhar; Vincent, Annette; Shomar, Basem
2018-05-29
Deteriorating water quality from aging infrastructure, growing threat of pollution from industrialization and urbanization, and increasing awareness about waterborne diseases are among the factors driving the surge in worldwide use of point-of-entry (POE) and point-of-use (POU) filters. Any adverse influence of such consumer point-of-use systems on quality of water at the tap remains poorly understood, however. We determined the chemical and microbiological changes in municipal water from the point of entry into the household plumbing system until it leaves from the tap in houses equipped with filters. We show that POE/POU devices can induce significant deterioration of the quality of tap water by functioning as traps and reservoirs for sludge, scale, rust, algae or slime deposits which promote microbial growth and biofilm formation in the household water distribution system. With changes in water pressure and physical or chemical disturbance of the plumbing system, the microorganisms and contaminants may be flushed into the tap water. Such changes in quality of household water carry a potential health risk which calls for some introspection in widespread deployment of POE/POU filters in water distribution systems.
Landwehr, Jurate M.; Coplen, Tyler B.; Stewart, David W.
2013-01-01
To assess spatial, seasonal, and source variability in stable isotopic composition of human drinking waters throughout the entire USA, we have constructed a database of δ18O and δ2H of US tap waters. An additional purpose was to create a publicly available dataset useful for evaluating the forensic applicability of these isotopes for human tissue source geolocation. Samples were obtained at 349 sites, from diverse population centres, grouped by surface hydrologic units for regional comparisons. Samples were taken concurrently during two contrasting seasons, summer and winter. Source supply (surface, groundwater, mixed, and cistern) and system (public and private) types were noted. The isotopic composition of tap waters exhibits large spatial and regional variation within each season as well as significant at-site differences between seasons at many locations, consistent with patterns found in environmental (river and precipitation) waters deriving from hydrologic processes influenced by geographic factors. However, anthropogenic factors, such as the population of a tap’s surrounding community and local availability from diverse sources, also influence the isotopic composition of tap waters. Even within a locale as small as a single metropolitan area, tap waters with greatly differing isotopic compositions can be found, so that tap water within a region may not exhibit the spatial or temporal coherence predicted for environmental water. Such heterogeneities can be confounding factors when attempting forensic inference of source water location, and they underscore the necessity of measurements, not just predictions, with which to characterize the isotopic composition of regional tap waters. Published 2013. This article is a U.S. Government work and is in the public domain in the USA.
Liu, Boning; Reckhow, David A
2013-10-15
This paper demonstrates that disinfection byproducts (DBP) concentration profiles in heated water were quite different from the DBP concentrations in the cold tap water. Chloroform concentrations in the heated water remained constant or even decreased slightly with increasing distribution system water age. The amount of dichloroacetic acid (DCAA) was much higher in the heated water than in the cold water; however, the maximum levels in heated water with different distribution system water ages did not differ substantially. The levels of trichloroacetic acid (TCAA) in the heated water were similar to the TCAA levels in the tap water, and a slight reduction was observed after the tap water was heated for 24 h. Regardless of water age, significant reductions of nonregulated DBPs were observed after the tap water was heated for 24 h. For tap water with lower water ages, there were significant increases in dichloroacetonitrile (DCAN), chloropicrin (CP), and 1,1-dichloropropane (1,1-DCP) after a short period of heating. Heating of the tap water with low pH led to a more significant increase of chloroform and a more significant short-term increase of DCAN. High pH accelerated the loss of the nonregulated DBPs in the heated water. The results indicated that as the chlorine doses increased, levels of chloroform and DCAA in the heated water increased significantly. However, for TCAA, the thermally induced increase in concentration was only notable for the chlorinated water with very high chlorine dose. Finally, heating may lead to higher DBP concentrations in chlorinated water with lower distribution system temperatures.
Zhuravlev, P V; Aleshnia, V V; Panasovets, O P; Morozova, A A; Artemova, T Z; Talaeva, Iu G; Zagaĭnova, A V; Gipp, E K
2012-01-01
Due to intensive anthropogenic pollution of water environment generally accepted indicators of epidemic security of water bodies - common bacteria and thermotolerant coliform bacteria do not always permit to obtain an objective characterization of bacterial contamination of tap water. From the point of view of authors the integral index - glucose positive coliform bacteria most adequately reflect the sanitary-hygienic and epidemiological situation of water bodies. In monitoring for bacterial quality of tap water it is advisable to determine glucose positive coliform bacteria, that will provide the relevance of estimation of the epidemiological safety of water use. According to the method developed by the authors the calculation of the index of population risk of acute intestinal infections occurrence in dependence on the quality of tap water in Azov and Tsimlyansk towns.
Morales-Pinzón, Tito; Lurueña, Rodrigo; Gabarrell, Xavier; Gasol, Carles M; Rieradevall, Joan
2014-02-01
A study was conducted to determine the financial and environmental effects of water quality on rainwater harvesting systems. The potential for replacing tap water used in washing machines with rainwater was studied, and then analysis presented in this paper is valid for applications that include washing machines where tap water hardness may be important. A wide range of weather conditions, such as rainfall (284-1,794 mm/year); water hardness (14-315 mg/L CaCO3); tap water prices (0.85-2.65 Euros/m(3)) in different Spanish urban areas (from individual buildings to whole neighbourhoods); and other scenarios (including materials and water storage capacity) were analysed. Rainfall was essential for rainwater harvesting, but the tap water prices and the water hardness were the main factors for consideration in the financial and the environmental analyses, respectively. The local tap water hardness and prices can cause greater financial and environmental impacts than the type of material used for the water storage tank or the volume of the tank. The use of rainwater as a substitute for hard water in washing machines favours financial analysis. Although tap water hardness significantly affects the financial analysis, the greatest effect was found in the environmental analysis. When hard tap water needed to be replaced, it was found that a water price of 1 Euro/m(3) could render the use of rainwater financially feasible when using large-scale rainwater harvesting systems. When the water hardness was greater than 300 mg/L CaCO3, a financial analysis revealed that an net present value greater than 270 Euros/dwelling could be obtained at the neighbourhood scale, and there could be a reduction in the Global Warming Potential (100 years) ranging between 35 and 101 kg CO2 eq./dwelling/year. Copyright © 2013 Elsevier B.V. All rights reserved.
Quinn, Casey W; Cate, David M; Miller-Lionberg, Daniel D; Reilly, Thomas; Volckens, John; Henry, Charles S
2018-03-20
Metal contamination of natural and drinking water systems poses hazards to public and environmental health. Quantifying metal concentrations in water typically requires sample collection in the field followed by expensive laboratory analysis that can take days to weeks to obtain results. The objective of this work was to develop a low-cost, field-deployable method to quantify trace levels of copper in drinking water by coupling solid-phase extraction/preconcentration with a microfluidic paper-based analytical device. This method has the advantages of being hand-powered (instrument-free) and using a simple "read by eye" quantification motif (based on color distance). Tap water samples collected across Fort Collins, CO, were tested with this method and validated against ICP-MS. We demonstrate the ability to quantify the copper content of tap water within 30% of a reference technique at levels ranging from 20 to 500 000 ppb. The application of this technology, which should be sufficient as a rapid screening tool, can lead to faster, more cost-effective detection of soluble metals in water systems.
Relationship between the incidence infection stones and the magnesium-calcium ratio of tap water.
Kohri, K; Ishikawa, Y; Iguchi, M; Kurita, T; Okada, Y; Yoshida, O
1993-01-01
In a previous study we showed that the magnesium-calcium ratio of tap water is negatively correlated with the incidence of calcium-containing urinary stones. In this study we examined the relationship between the incidence of struvite stones, water hardness and the regional geological features on the basis of our previous study and an epidemiological study of urolithiasis performed in Japan. The magnesium-calcium ratio of tap water was found to correlate positively with the incidence of struvite stones. The tap water magnesium-calcium ratio was high in regions of basalt and sedimentary rock and was low in granite and limestone areas. The incidence of struvite stones in the regions of basalt and sedimentary rock was higher than that in the granite and limestone areas. Thus, this study suggested that the incidence of struvite stones is related to the magnesium-calcium ratio of tap water and to the regional geology, as is the case for calcium-containing stones.
Contribution of diet to aggregate arsenic exposures—An analysis across populations
Kurzius-Spencer, Margaret; Burgess, Jefferey L.; Harris, Robin B.; Hartz, Vern; Roberge, Jason; Huang, Shuang; Hsu, Chiu-Hsieh; O'Rourke, MK
2014-01-01
The relative contribution of dietary arsenic (As) to aggregate daily exposure has not been well-characterized, especially in relation to the current EPA maximum contaminant level (MCL) of 10 p.p.b. for As in drinking water. Our objectives were to: (1) model exposure to inorganic and total As among non-seafood eaters using subject-specific data, (2) compare the contribution of food, drinking and cooking water to estimated aggregate exposure in households with variable background tap water As levels, and (3) describe the upper distribution of potential dose at different thresholds of tap water As. Dietary As intake was modeled in regional study populations and NHANES 2003–2004 using dietary records in conjunction with published food As residue data. Water As was measured in the regional studies. Among subjects exposed to tap water As >10 p.p.b., aggregate inorganic exposure was 24.5–26.1 μg/day, with approximately 30% of intake from food. Among subjects living in homes with tap water As ≤10, 5 or 3 p.p.b., aggregate inorganic As exposure was 8.6–11.8 μg/day, with 54–85% of intake from food. Median inorganic As potential dose was 0.42–0.50 μg/kg BW/day in subjects exposed to tap water As >10 p.p.b. and less than half that among subjects exposed to tap water As ≤10 p.p.b. The majority of inorganic and total As exposure is attributable to diet in subjects with tap water As
Zhuravlev, P V; Aleshnya, V V; Panasovets, O P; Morozova, A A; Artemova, T Z; Talaeva, Yu G; Zagaynova, A V
2013-01-01
Due to intensive anthropogenic pollution of water environment generally accepted indicators of epidemic security of water bodies--common bacteria (CB) and thermotolerant coliform bacteria (TCB) do not always permit to obtain an objective characterization of bacterial contamination of tap water. From the point of view of authors the integral index--glucose positive coliform bacteria most adequately reflect the sanitary-hygienic and epidemiological situation of water bodies. In monitoring for bacterial quality of tap water it is advisable to determine glucose positive coliform bacteria, that will provide the relevance of estimation of the epidemiological safety of water use. According to the method developed by the authors the calculation of the index of population risk of acute intestinal infections (AHI) occurrence in dependence on the quality of tap water in Azov and Tsimlyansk towns.
Identification and description of potential ground-water quality monitoring wells in Florida
Seaber, P.R.; Thagard, M.E.
1986-01-01
The results of a survey of existing wells in Florida that meet the following criteria are presented: (1) well location is known , (2) principal aquifer is known, (3) depth of well is known, (4) well casing depth is known, (5) well water had been analyzed between 1970 and 1982, and (6) well data are stored in the U.S. Geological Survey 's (USGS) computer files. Information for more than 20,000 wells in Florida were stored in the USGS Master Water Data Index of the National Water Data Exchange and in the National Water Data Storage and Retrieval System 's Groundwater Site Inventory computerized files in 1982. Wells in these computer files that had been sampled for groundwater quality before November 1982 in Florida number 13,739; 1,846 of these wells met the above criteria and are the potential (or candidate) groundwater quality monitoring wells included in this report. The distribution by principal aquifer of the 1,846 wells identified as potential groundwater quality monitoring wells is as follows: 1,022 tap the Floridan aquifer system, 114 tap the intermediate aquifers, 232 tap the surficial aquifers, 246 tap the Biscayne aquifer, and 232 tap the sand-and-gravel aquifer. These wells are located in 59 of Florida 's 67 counties. This report presents the station descriptions, which include location , site characteristics, period of record, and the type and frequency of chemical water quality data collected for each well. The 1,846 well locations are plotted on 14 USGS 1:250,000 scale, 1 degree by 2 degree, quadrangle maps. This relatively large number of potential (or candidate) monitoring wells, geographically and geohydrologically dispersed, provides a basis for a future groundwater quality monitoring network and computerized data base for Florida. There is a large variety of water quality determinations available from these wells, both areally and temporally. Future sampling of these wells would permit analyses of time and areal trends for selected water quality characteristics throughout the State. The identification and description of the potential monitoring wells and the listing of the type and frequency of the groundwater quality data forms a foundation for both the network and the data base. (Author 's abstract)
Divergence of stable isotopes in tap water across China
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Sihan; Hu, Hongchang; Tian, Fuqiang
Stable isotopes in water (e.g., δ2H and δ18O) are important indicators of hydrological and ecological patterns and processes. Tap water can reflect integrated features of regional hydrological processes and human activities. China is a large country with significant meteorological and geographical variations. This report presents the first national-scale survey of Stable Isotopes in Tap Water (SITW) across China. 780 tap water samples have been collected from 95 cities across China from December 2014 to December 2015. (1) Results yielded the Tap Water Line in China is δ2H = 7.72 δ18O + 6.57 (r2 = 0.95). (2) SITW spatial distribution presentsmore » typical "continental effect". (3) SITW seasonal variations indicate clearly regional patterns but no trends at the national level. (4) SITW can be correlated in some parts with geographic or meteorological factors. This work presents the first SITW map in China, which sets up a benchmark for further stable isotopes research across China. This is a critical step toward monitoring and investigating water resources in climate-sensitive regions, so the human-hydrological system. These findings could be used in the future to establish water management strategies at a national or regional scale. Title: Divergence of stable isotopes in tap water across China Authors: Zhao, SH; Hu, HC; Tian, FQ; Tie, Q; Wang, LX; Liu, YL; Shi, CX Source: SCIENTIFIC REPORTS, 7 10.1038/srep43653 MAR 2 2017« less
Leung, Ho Wing; Jin, Ling; Wei, Si; Tsui, Mirabelle Mei Po; Zhou, Bingsheng; Jiao, Liping; Cheung, Pak Chuen; Chun, Yiu Kan
2013-01-01
Background: Pharmaceuticals are known to contaminate tap water worldwide, but the relevant human health risks have not been assessed in China. Objectives: We monitored 32 pharmaceuticals in Chinese tap water and evaluated the life-long human health risks of exposure in order to provide information for future prioritization and risk management. Methods: We analyzed samples (n = 113) from 13 cities and compared detected concentrations with existing or newly-derived safety levels for assessing risk quotients (RQs) at different life stages, excluding the prenatal stage. Results: We detected 17 pharmaceuticals in 89% of samples, with most detectable concentrations (92%) at < 50 ng/L. Caffeine (median–maximum, nanograms per liter: 24.4–564), metronidazole (1.8–19.3), salicylic acid (16.6–41.2), clofibric acid (1.2–3.3), carbamazepine (1.3–6.7), and dimetridazole (6.9–14.7) were found in ≥ 20% of samples. Cities within the Yangtze River region and Guangzhou were regarded as contamination hot spots because of elevated levels and frequent positive detections. Of the 17 pharmaceuticals detected, 13 showed very low risk levels, but 4 (i.e., dimetridazole, thiamphenicol, sulfamethazine, and clarithromycin) were found to have at least one life-stage RQ ≥ 0.01, especially for the infant and child life stages, and should be considered of high priority for management. We propose an indicator-based monitoring framework for providing information for source identification, water treatment effectiveness, and water safety management in China. Conclusion: Chinese tap water is an additional route of human exposure to pharmaceuticals, particularly for dimetridazole, although the risk to human health is low based on current toxicity data. Pharmaceutical detection and application of the proposed monitoring framework can be used for water source protection and risk management in China and elsewhere. PMID:23665928
Predicting consumer preferences for mineral composition of bottled and tap water.
Platikanov, Stefan; Hernández, Alejandra; González, Susana; Luis Cortina, Jose; Tauler, Roma; Devesa, Ricard
2017-01-01
The overall liking for taste of water was correlated with the mineral composition of selected bottled and tap waters. Sixty-nine untrained volunteers assessed and rated twenty-five different commercial bottled and tap waters from. Water samples were physicochemical characterised by analysing conductivity, pH, total dissolved solids (TDS) and major anions and cations: HCO 3 - , SO 4 2- , Cl - , NO 3 - , Ca 2+ , Mg 2+ , Na + , and K + . Residual chlorine levels were also analysed in the tap water samples. Globally, volunteers preferred waters rich in calcium bicarbonate and sulfate, rather than in sodium chloride. This study also demonstrated that it was possible to accurately predict the overall liking by a Partial Least Squares regression using either all measured physicochemical parameters or a reduced number of them. These results were in agreement with previously published results using trained panellists. Copyright © 2016 Elsevier B.V. All rights reserved.
Lu, Guo-Hui; Gai, Nan; Zhang, Peng; Piao, Hai-Tao; Chen, Shu; Wang, Xiao-Chun; Jiao, Xing-Chun; Yin, Xiao-Cai; Tan, Ke-Yan; Yang, Yong-Liang
2017-10-01
Perfluoroalkyl acids (PFAAs) are widely used as multi-purpose surfactants or water/oil repellents. In order to understand the contamination level and compositional profiles of PFAAs in aqueous environment in textile, leather, and paper making industrial areas, surface waters and tap waters were collected along the watershed of the Qiantang River where China's largest textile, leather, and paper making industrial bases are located. For comparison, surface water and tapwater samples were also collected in Hangzhou and its adjacent areas. 17 PFAAs were analyzed by solid phase extraction-high performance liquid chromatography-tandem mass spectrometry. The results show that the total concentrations of PFAAs (ΣPFAAs) in the Qiantang River waters ranged from 106.1 to 322.9 ng/L, averaging 164.2 ng/L. The contamination levels have been found to be extremely high, comparable to the levels of the most serious PFAA contamination in surface waters of China. The PFAA composition profiles were characterized by the dominant PFOA (average 58.1% of the total PFAAs), and PFHxA (average 18.8%). The ΣPFAAs in tap water ranged from 9.5 to 174.8 ng/L, showing PFAA compositional pattern similar to the surface waters. Good correlations between PFAA composition profiles in tap waters and the surface waters were observed. Copyright © 2017 Elsevier Ltd. All rights reserved.
Determination of uranium in tap water by ICP-MS.
El Himri, M; Pastor, A; de la Guardia, M
2000-05-01
A fast and accurate procedure has been developed for the determination of uranium at microg L(-1) level in tap and mineral water. The method is based on the direct introduction of samples, without any chemical pre-treatment, into an inductively coupled plasma mass spectrometer (ICP-MS). Uranium was determined at the mass number 238 using Rh as internal standard. The method provides a limit of detection of 2 ng L(-1) and a good repeatability with relative standard deviation values (RSD) about 3% for five independent analyses of samples containing 73 microg L(-1) of uranium. Recovery percentage values found for the determination of uranium in spiked natural samples varied between 91% and 106%. Results obtained are comparable with those found by radiochemical methods for natural samples and of the same order for the certified content of a reference material, thus indicating the accuracy of the ICP-MS procedure without the need of using isotope dilution. A series of mineral and tap waters from different parts of Spain and Morocco were analysed.
Zeng, Hui; Chen, Ji-an; Liu, Lin; Wang, Da-hua; Fu, Wen-juan; Wang, Ling-qiao; Luo, Jiao-hua; Zhang, Liang; Tan, Yao; Qiu, Zhi-qun; Huang, Yu-jing; Shu, Wei-qun
2014-01-01
Tap water (unfiltered), filtered tap water and processed bottled water (purified water, artificial mineralized water, or natural water) are now the five most widely consumed types of drinking water in China. However, the constituents (organic chemicals and inorganic ingredients) of the five waters differ, which may cause them to have different long-term health effects on those who drink them, especially sensitive children. In order to determine which type of water among the five waters is the most beneficial regarding reproductive outcomes and the developmental behaviors of offspring, two generations of Sprague-Dawley rats were given these five waters separately, and their reproductive outcomes and the developmental behaviors of their offspring were observed and compared. The results showed that the unfiltered tap water group had the lowest values for the maternal gestation index (MGI) and offspring's learning and memory abilities (OLMA); the lowest offspring survival rate was found in the purified water group; and the highest OLMA were found in the filtered tap water group. Thus, the best reproductive and offspring early developmental outcomes were found in the group that drank filtered tap water, which had the lowest levels of pollutants and the richest minerals. Therefore, thoroughly removing toxic contaminants and retaining the beneficial minerals in drinking water may be important for both pregnant women and children, and the best way to treat water may be with granular activated carbon and ion exchange by copper zinc alloy.
Zeng, Hui; Shu, Wei-qun; Chen, Ji-an; Liu, Lin; Wang, Da-hua; Fu, Wen-juan; Wang, Ling-qiao; Luo, Jiao-hua; Zhang, Liang; Tan, Yao; Qiu, Zhi-qun; Huang, Yu-jing
2014-01-01
Tap water (unfiltered), filtered tap water and processed bottled water (purified water, artificial mineralized water, or natural water) are now the five most widely consumed types of drinking water in China. However, the constituents (organic chemicals and inorganic ingredients) of the five waters differ, which may cause them to have different long-term health effects on those who drink them, especially sensitive children. In order to determine which type of water among the five waters is the most beneficial regarding reproductive outcomes and the developmental behaviors of offspring, two generations of Sprague–Dawley rats were given these five waters separately, and their reproductive outcomes and the developmental behaviors of their offspring were observed and compared. The results showed that the unfiltered tap water group had the lowest values for the maternal gestation index (MGI) and offspring's learning and memory abilities (OLMA); the lowest offspring survival rate was found in the purified water group; and the highest OLMA were found in the filtered tap water group. Thus, the best reproductive and offspring early developmental outcomes were found in the group that drank filtered tap water, which had the lowest levels of pollutants and the richest minerals. Therefore, thoroughly removing toxic contaminants and retaining the beneficial minerals in drinking water may be important for both pregnant women and children, and the best way to treat water may be with granular activated carbon and ion exchange by copper zinc alloy. PMID:25279561
Diversity and antibiotic resistance of Aeromonas spp. in drinking and waste water treatment plants.
Figueira, Vânia; Vaz-Moreira, Ivone; Silva, Márcia; Manaia, Célia M
2011-11-01
The taxonomic diversity and antibiotic resistance phenotypes of aeromonads were examined in samples from drinking and waste water treatment plants (surface, ground and disinfected water in a drinking water treatment plant, and raw and treated waste water) and tap water. Bacteria identification and intra-species variation were determined based on the analysis of the 16S rRNA, gyrB and cpn60 gene sequences. Resistance phenotypes were determined using the disc diffusion method. Aeromonas veronii prevailed in raw surface water, Aeromonas hydrophyla in ozonated water, and Aeromonas media and Aeromonas puntacta in waste water. No aeromonads were detected in ground water, after the chlorination tank or in tap water. Resistance to ceftazidime or meropenem was detected in isolates from the drinking water treatment plant and waste water isolates were intrinsically resistant to nalidixic acid. Most of the times, quinolone resistance was associated with the gyrA mutation in serine 83. The gene qnrS, but not the genes qnrA, B, C, D or qepA, was detected in both surface and waste water isolates. The gene aac(6')-ib-cr was detected in different waste water strains isolated in the presence of ciprofloxacin. Both quinolone resistance genes were detected only in the species A. media. This is the first study tracking antimicrobial resistance in aeromonads in drinking, tap and waste water and the importance of these bacteria as vectors of resistance in aquatic environments is discussed. Copyright © 2011 Elsevier Ltd. All rights reserved.
Introduction The current study investigated the effect of different disinfection treatments on the disinfection by-products (DBPs) formed in finished drinking water vs. tap water vs. swimming pool water vs. spa waters. To this end, samples across the complete water pathway (untr...
The current study investigates the effect of different disinfection treatments on the disinfection by-products (DBPs) formed in finished drinking water vs. tap water vs. swimming pool water vs. spa waters. To this end, complete water pathway samples (untreated source waters ->fi...
HUMAN EXPOSURE TO WATER DISINFECTION BY-PRODUCTS VIA FOODS AND BEVERAGES
The ingestion of tap water is a major route of exposure to water disinfection byproducts (DBPs), including haloacetonitriles, haloketones, and haloacetic acids. A potentially significant alternate route of exposure is through the consumption of beverages prepared with tap water ...
Analysis of UV filters in tap water and other clean waters in Spain.
Díaz-Cruz, M Silvia; Gago-Ferrero, Pablo; Llorca, Marta; Barceló, Damià
2012-03-01
The present paper describes the development of a method for the simultaneous determination of five hormonally active UV filters namely benzophenone-3 (BP3), 3-(4-methylbenzylidene) camphor (4MBC), 2-ethylhexyl 4-(dimethylamino) benzoate (OD-PABA), 2-ethylhexyl 4-methoxycinnamate (EHMC) and octocrylene (OC) by means of solid-phase extraction and gas chromatography-electron impact ionization-mass spectrometry. Under optimized conditions, this methodology achieved low method limits of detection (needed for clean waters, especially drinking water analysis), between 0.02 and 8.42 ng/L, and quantitative recovery rates higher than 73% in all cases. Inter- and intraday precision for all compounds were lower than 7% and 11%, respectively. The optimized methodology was applied to perform the first survey of UV absorbing compounds in tap water from the metropolitan area and the city of Barcelona (Catalonia, Spain). In addition, other types of clean water matrices (mineral bottled water, well water and tap water treated with an ion-exchange resin) were investigated as well. Results evidenced that all the UV filters investigated were detected in the water samples analyzed. The compounds most frequently found were EHMC and OC. Maximum concentrations reached in tap water were 290 (BP3), 35 (4MBC), 110 (OD-PABA), 260 (EHMC), and 170 ng/L (OC). This study constitutes the first evidence of the presence of UV filter residues in tap water in Europe.
Li, Xu; Ying, Guang-Guo; Su, Hao-Chang; Yang, Xiao-Bing; Wang, Li
2010-08-01
This study investigated the levels of 4-nonylphenol (4-NP), bisphenol A (BPA) and triclosan (TCS) in bottled water and tap water in Guangzhou and release of these chemicals from baby bottles using gas chromatography-mass spectrometry with negative chemical ionization. Results show that 4-NP was present in all the bottled water while 17 out of 21 contained BPA and 18 out of 21 contained TCS. Their concentrations in bottled water ranged from 108 to 298 ng/L, 17.6 to 324 ng/L and 0.6 to 9.7 ng/L, respectively. Five of the tap water samples from six drinking water plants were found to contain 4-NP and BPA both in June and December, while TCS was detected in the same five plants only in June. The highest concentrations in tap water for 4-NP, BPA and TCS were 1987, 317 and 14.5ng/L, respectively. Daily intakes of 4-NP, BPA and TCS of adults by drinking 2L of tap water were estimated to be 1410, 148 and 10 ng/day, respectively. BPA was found to be released within 24h from four brands of baby bottles at room temperature (24 degrees C), 40 degrees C and 100 degrees C. Increased temperature led to higher release of BPA from the baby bottles. Estimated daily intakes of 4-NP, BPA and TCS for infants were 705, 1340 and 5 ng/day, respectively, by drinking 1L of tap water from a baby bottle at 40 degrees C. This study showed that the exposure to the three compounds from drinking water is unlikely to pose a health risk. Copyright 2010 Elsevier Ltd. All rights reserved.
Dai, Yifan; Liu, Chung Chiun
2017-01-01
This research has developed a simple to use, cost effective sensor system for the detection of lead ions in tap water. An under-potential deposited bismuth sub-layer on a thin gold film based electrochemical sensor was designed, manufactured, and evaluated. Differential pulse voltammetry (DPV) measurement technique was employed in this detection. Tap water from the Cleveland, OH, USA regional water district was the test medium. Concentrations of lead ion in the range of 8 × 10−7 M to 5 × 10−4 M were evaluated, showing a good sensitivity over this concentration range. The calibration curve for the DPV measurements of lead ions in tap water showed excellent reproducibility with R2 value of 0.970. This DPV detection system required 3–6 min to complete the detection measurement. A longer measurement time of 6 min was used for the lower lead ion concentration. The selectivity of this lead ion sensor was very good, and Fe III, Cu II, Ni II, and Mg II at a concentration level of 5 × 10−4 M did not interfere with the lead ion measurement. PMID:28441356
&LDQUO;FROM THE SOURCE &NDASH; TAP WATER AS A SUSTAINABLE ALTERNATIVE&RDQUO;
The major technical challenge to sustainability is reduction of use of plastic bottled water and bottled water in general. This will be done by a student administered water assessment survey on campus, coupled with a public education campaign on the benefits of using tap water...
Major inorganic elements in tap water samples in Peninsular Malaysia.
Azrina, A; Khoo, H E; Idris, M A; Amin, I; Razman, M R
2011-08-01
Quality drinking water should be free from harmful levels of impurities such as heavy metals and other inorganic elements. Samples of tap water collected from 24 locations in Peninsular Malaysia were determined for inorganic element content. Minerals and heavy metals were analysed by spectroscopy methods, while non-metal elements were analysed using test kits. Minerals and heavy metals determined were sodium, magnesium, potassium, calcium, chromium, manganese, iron, nickel, copper, zinc, arsenic, cadmium and lead while the non-metal elements were fluoride, chloride, nitrate and sulphate. Most of the inorganic elements found in the samples were below the maximum permitted levels recommended by inter-national drinking water standard limits, except for iron and manganese. Iron concentration of tap water from one of the locations was higher than the standard limit. In general, tap water from different parts of Peninsular Malaysia had low concentrations of heavy metals and inorganic elements.
Kurzius-Spencer, Margaret; Harris, Robin B.; Hartz, Vern; Roberge, Jason; Hsu, Chiu-Hsieh; O’Rourke, Mary Kay; Burgess, Jefferey L.
2015-01-01
Arsenic (As) exposure is associated with cancer, lung and cardiovascular disease, yet the mechanisms involved are not clearly understood. Elevated matrix metalloproteinase-9 (MMP-9) levels are also associated with these diseases, as well as with exposure to water As. Our objective was to evaluate the effects of dietary components of inorganic As (iAs) intake on serum MMP-9 concentration at differing levels of tap water As. In a cross-sectional study of 214 adults, dietary iAs intake was estimated from 24-h dietary recall interviews using published iAs residue data; drinking and cooking water As intake from water samples and consumption data. Aggregate iAs intake (food plus water) was associated with elevated serum MMP-9 in mixed model regression, with and without adjustment for covariates. In models stratified by tap water As, aggregate intake was a significant positive predictor of serum MMP-9 in subjects exposed to water As ≤10 μg/l. Inorganic As from food alone was associated with serum MMP-9 in subjects exposed to tap water As ≤3 μg/l. Exposure to iAs from food and water combined, in areas where tap water As concentration is ≤10 μg/l, may contribute to As-induced changes in a biomarker associated with toxicity. PMID:25605447
40 CFR 141.88 - Monitoring requirements for lead and copper in source water.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the basis of tap samples collected in accordance with § 141.86 shall collect lead and copper source... value or be considered one-half the PQL. (b) Monitoring frequency after system exceeds tap water action level. Any system which exceeds the lead or copper action level at the tap shall collect one source...
Risk characterization of methyl tertiary butyl ether (MTBE) in tap water.
Stern, B R; Tardiff, R G
1997-12-01
Methyl tertiary butyl ether (MTBE) can enter surface water and groundwater through wet atmospheric deposition or as a result of fuel leaks and spills. About 30% of the U.S. population lives in areas where MTBE is in regular use. Ninety-five percent of this population is unlikely to be exposed to MTBE in tap water at concentrations exceeding 2 ppb, and most will be exposed to concentrations that are much lower and may be zero. About 5% of this population may be exposed to higher levels of MTBE in tap water, resulting from fuel tank leaks and spills into surface or groundwater used for potable water supplies. This paper describes the concentration ranges found and anticipated in surface and groundwater, and estimates the distribution of doses experienced by humans using water containing MTBE to drink, prepare food, and shower/bathe. The toxic properties (including potency) of MTBE when ingested, inhaled, and in contact with the skin are summarized. Using a range of human toxic potency values derived from animal studies, margins of exposure (MOE) associated with alternative chronic exposure scenarios are estimated to range from 1700 to 140,000. Maximum concentrations of MTBE in tap water anticipated not to cause adverse health effects are determined to range from 700 to 14,000 ppb. The results of this analysis demonstrate that no health risks are likely to be associated with chronic and subchronic human exposures to MTBE in tap water. Although some individuals may be exposed to very high concentrations of MTBE in tap water immediately following a localized spill, these exposures are likely to be brief in duration due to large-scale dilution and rapid volatilization of MTBE, the institution of emergency response and remediation measures to minimize human exposures, and the low taste and odor thresholds of MTBE which ensure that its presence in tap water is readily detected at concentrations well below the threshold for human injury.
Effect of balneotherapy on the antioxidant system--a controlled pilot study.
Bender, Tamás; Bariska, János; Vághy, Richárd; Gomez, Roberto; Imre Kovács
2007-01-01
Balneotherapy is among the most widely used modalities of physical therapy in countries rich in mineral waters. This trial was intended to ascertain whether balneotherapy (i.e., therapeutic bath in mineral water) has any influence on the antioxidant system and whether there are any differences compared to bathing in tap water. The ten subjects in Group I bathed in alkaline thermal water, Group II used alkaline, chlorine-containing mineral water, whereas Group III bathed in tap water. Catalase, superoxide dismutase, malondialdehyde protein and glutathione peroxidase levels were measured at baseline and after concluding the course of balneotherapy. Balneotherapy with either of the two mineral waters reduced the activity of all four enzymes studied. Using tap water, however, had no influence on either catalase or superoxide dismutase activity after one session or glutathione peroxidase levels after a course of ten balneotherapy treatments. Thermal water may have a beneficial effect on the formation of free radicals. The therapeutic efficacy of mineral vs. tap water is different, although bathing in hot water itself reduces enzyme activity.
Neural Tube Defects In Mice Exposed To Tap Water
Mallela, Murali K; Werre, Stephen R; Hrubec, Terry C
2010-01-01
In May of 2006 we suddenly began to observe neural tube defects (NTDs) in embryos of untreated control mice. We hypothesized the mice were being exposed unknowingly to a teratogenic agent and investigated the cause. Our results suggested that NTDs were not resulting from bedding material, feed, strain or source of the mice. Additionally, mice were negative for routine and comprehensive screens of pathogens. To further test whether the NTDs resulted from infectious or genetic cause localized to our facility, we obtained three strains of timed pregnant mice from commercial suppliers located in 4 different states. All strains and sources of mice arrived in our laboratory with NTDs, implying that commercially available mice were possibly exposed to a teratogen prior to purchase. Our investigation eventually concluded that exposure to tap water was causing the NTDs. The incidence of NTDs was greatest in purchased mice provided tap water and lowest in purchased mice provided distilled deionized water (DDI). Providing mice DDI water for two generations (F2-DDI) eliminated the NTDs. When F2-DDI mice were provided tap water from three different urban areas prior to breeding, their offspring again developed NTDs. Increased length of exposure to tap water significantly increased the incidence of NTDs. These results indicate that a contaminant in municipal tap water is likely causing NTDs in mice. The unknown teratogen appears to have a wide geographic distribution but has not yet been identified. Water analysis is currently underway to identify candidate contaminants that might be responsible for the malformations. PMID:20549630
Shizuma, Kiyoshi; Fujikawa, Yoko; Kurihara, Momo; Sakurai, Yushi
2018-03-01
The Fukushima Dai-ichi Nuclear Power Plant (FDNPP) accident on March 11, 2011, caused severe radioactive contamination in Fukushima Prefecture. In order to clarify the safety of drinking water, we have conducted radiocesium monitoring of public tap water and groundwater in Minami-Soma City, which is 10-40 km north of the nuclear power plant. The source of tap water for Minami-Soma City is groundwater, which is treated by rapid filtration before distribution in two of the three treatment plants. The tap water was collected from six stations during 2012-2016 and groundwater was collected from 11 stations with wells between 5 and 100 m deep during 2014-2016. Radiocesium contamination of groundwater has been considered unlikely in Japan because of the small vertical migration velocity of radiocesium in Japanese soil. However, radiocesium was detected in public tap water after 2012, and the maximum 137 Cs concentration of 292 mBq L -1 was observed in 2013. In all the well water, radiocesium was detected between 2014 and 2015, at concentrations similar to those observed in tap water in the same period. In tap water and groundwater, radiocesium was decreased to below the detection limit in 2016 except for four stations. Radiocesium concentration in shallow water reached a maximum between 2013 and 2015, 2-4 years after the FDNPP accident, and then decreased. The results are interpreted that dissolved 137 Cs migrated in the soil and reached aquifers of various depth. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Sola, P.; Youngchuay, U.; Kongsri, S.; Kongtana, A.
2017-06-01
Thailand Institute of Nuclear Technology (TINT) has continuously monitored radiation exposure and radionuclide in workplaces specifically radon gas to estimate effective dose for workers. Radon exposure is the second leading cause of lung cancer in the world. In this study, radon in air and tap water at building no. 3, 7, 8, 9 and 18 on Ongkharak site of TINT have been measured for 5 years from 2012 to 2016. Radon level in air and tap water were investigated on 83 stations (workplaces) and 54 samples, respectively. Radon concentrations in air and tap water were measured by using the pulsed ionization chamber (ATMOS 12 DPX). Indoor radon concentrations in air were in the range of 12-138 Bq.m-3 with an average value of 30.13±17.05 Bq.m-3. Radon concentrations in tap water were in the range of 0.10 to 2.89 Bq.l-1 with an average value of 0.51±0.55 Bq.l-1. The results of radon concentrations at TINT were below the US Environmental Protection Agency (US EPA) safety limit of 148 Bq.m-3 and 150 Bq.l-1, for, air and tap water, respectively. The average effective dose for TINT’s workers due to indoor radon exposure was approximately 0.20±0.11 mSv.y-1. The value is 100 times less than the annual dose limit for limit occupational radiation worker defined by the International Commission on Radiological Protection (ICRP). As a result, the TINT’s workplaces are radiologically safe from radon content in air and tap water.
Umezawa, Kazuo; Asai, Satomi; Ohshima, Toshio; Iwashita, Hideo; Ohashi, Maya; Sasaki, Mika; Kaneko, Akihiro; Inokuchi, Sadaki; Miyachi, Hayato
2015-11-01
An outbreak of amikacin- and ciprofloxacin-resistant Acinetobacter baumannii ST219 in Tokai University hospital's emergency intensive care unit was caused by its colonization in water systems and subsequent spread through oral care using tap water. The outbreak was successfully controlled after replacement of the water system and implementation as of daily cleaning of water taps and oral care with a dry method. It is important to strictly manage the water system in critical care areas. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Development of Thermoacoustic Sensors for Sodium-cooled Fast Reactors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heibel, Michael D.; Carvajal, Jorge V.; Ferroni, Paolo
This Final Report refers to the project “Development of Thermoacoustic Sensors for Sodium-cooled Fast Reactor Systems”, which was led by Westinghouse Electric Company (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and University of Pittsburgh. Thermo-acoustic Power Sensors (TAPS) are self-powered, wireless sensors envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. This project was intended to specifically investigate their applicability to Sodium-cooled Fast Reactors (SFR). TAPS are non-invasive (wireless) and passive (self-powered) devices. The passivity derives from their ability to use conditions that “naturally” exist in a nuclearmore » reactor, such as gamma and neutron flux, as power sources. They generate oscillating pressure waves (i.e., sound waves) which, with a frequency and amplitude dependent upon these conditions, can travel through the core and associated structures, and reach the outside of the reactor vessel where a properly designed network of receivers can detect and interpret them. These receivers require a very small amount of power which, during loss of power events, can be provided for example by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. The project aimed at TAPS development through a series of tasks which are listed and briefly discussed as follows. TASK 1 – Sensor hardware design Subtask 1a: Assessment of sensor applications to SFRs Subtask 1b: Development of sensor functional requirements Subtask 1c: Definition of sensor hardware design specifications Task description: TAPS design was informed by considerations on their application (Subtask 1a), both the ultimate one in an SFR and the actual one in the ANL testing facilities that was intended to be used in support of the project. Considerations were made to identify optimum sensor design features that optimize the sensor size, materials, and output signal, for installation inside an SFR core. These considerations led to the development of Functional Requirements (Subtask 1b) and Design Requirements (Subtask 1c). TASK 2 – Sensor Hardware Manufacture Subtask 2a: Sensor hardware construction drawing development Subtask 2b: Sensor manufacture and assembly Task description: TAPS technical drawings were developed (Subtask 2a) using the Design Requirements established under Task 1. Subsequently, in spite of some problems which ultimately caused the program to be delayed, TAPS manufacturing was completed based on drawings (Subtask 2b). TASK 3 – Development of TAPS Signal Measurement System and TAPS Testing in Water Subtask 3a: Design, assembly and testing of signal measurement system, and TAPS testing in water Subtask 3b: Signal prediction-correction methodology development Task description: An assessment was performed on the techniques that can potentially be used to detect the signals emitted by the TAPS, e.g. a fiber-optic based acoustic signal measurement system, a laser vibrometer system, or an accelerometer-based system. The most suited technology, i.e. the accelerometer-based system, was developed further, and tested in water (Subtask 3a). Moreover, efforts were made to develop the methodology required to determine the actual system temperature and neutron flux distribution using differences between the measured and predicted TAPS responses (Subtask 3b). TASK 4 – Sensor System Testing in Sodium Subtask 4a: Test plan development Subtask 4b: Design, assembly and testing in small-scale sodium facility Subtask 4c: Design, assembly and testing in large-scale sodium and structures facility Task description: Upon proper test plan development (Subtask 4a), the fabricated TAPS was planned to be tested in sodium, by using two sodium facilities at ANL having different size and different purpose. The Under Sodium Viewing (USV) small-scale facility was intended to be used to investigate the effect of sodium on the sensor and its performance (Subtask 4b). The Mechanism Engineering Test Loop (METL) large-scale facility was instead intended to be used to assess the additional effect of prototypical SFR structures, such as fuel assembly mockup or parts of the core restrain structure, on sensor performance (Subtask 4c). As discussed in Section 3.2.2.7, unexpected issues during the TAPS manufacturing process resulted in some activities being delayed, with the TAPS and USV facility developed to the point to be ready for testing in sodium, however without the possibility to actually perform such testing (including the testing in METL) due to the end of the program’s performance period. Overall, through the development and testing (in water only) of two TAPS devices (a First-Generation TAPS followed by an optimized Second-Generation TAPS), the project confirmed the capability of this technology to generate acoustic signals proportional to temperature, which can be detected through a network of accelerometers identified as the best-suited type of receivers for acoustic signal detection. Moreover, the project also developed a computational model to predict the characteristics of the acoustic signals being generated, which combines thermal analysis of the TAPS with Finite Element Modeling (FEM)-aided acoustic characterization of the system. This model was benchmarked against experimental data collected during the project and, although general agreement was obtained, some limitations of the modeling methods were identified, which require additional development. Additional testing is needed in order to assess the effect, on TAPS operation and performance, of environmental changes resulting from the transition from water to liquid sodium. Such testing, which is suggested to be performed in the future, should look specifically at 1) both the effect resulting from the different thermoacoustic behavior of sodium (relative to water) and the effects of higher temperature on TAPS performance, and 2) the performance of the sensor-receiver system when multiple TAPS are used simultaneously and prototypical reactor structures are positioned in the testing environment. The latter testing is needed to assess the effects that potential signal attenuation/ distortion phenomena, as well as potential interference between signals emitted simultaneously, have on the performance of the technology for ultimate application in a nuclear reactor.« less
Kohri, K; Kodama, M; Ishikawa, Y; Katayama, Y; Takada, M; Katoh, Y; Kataoka, K; Iguchi, M; Kurita, T
1989-11-01
We examined the relationship among magnesium and calcium content in tap water, the geological features and urinary stone incidence in Japan. The magnesium-to-calcium ratio in tap water correlated negatively with the incidence of urolithiasis. There was no correlation between calcium and magnesium concentration in tap water and urinary stone incidence. Geological features in Japan were classified into 5 groups. The magnesium-to-calcium ratio in the basalt areas was higher than in the other areas, while ratio in the granite areas was low. In the sedimentary rock areas calcium and magnesium concentrations were high; the magnesium-to-calcium ratio in these areas was between those of the basalt and granite areas. The limestone areas had a much higher calcium concentration. The incidence of urinary stones in the sedimentary rock and basalt areas was lower than that of the granite areas, while that in the limestone areas was the highest. Thus, the incidence of urinary stone is related to the magnesium-to-calcium ratio in tap water and the geological area.
Franje, Catherine A; Chang, Shao-Kuang; Shyu, Ching-Lin; Davis, Jennifer L; Lee, Yan-Wen; Lee, Ren-Jye; Chang, Chao-Chin; Chou, Chi-Chung
2010-12-01
Heat stability of amphenicols and the relationship between structural degradation and antimicrobial activity after heating has not been well investigated. Florfenicol (FF), thiamphenicol (TAP), and chloramphenicol (CAP) were heated at 100 degrees C in water, salt water, soybean sauce and chicken meat for up to 2h. Degradation and antimicrobial activity of the compounds was evaluated using capillary electrophoresis (CE) with UV-DAD spectrometry, minimum inhibitory concentration (MIC) assay, and gas chromatography with electron impact ionization mass spectrometry (GC-EI-MS). Heat stability of amphenicols in matrices was ranked as water> or =salt water>soybean sauce>meat, suggesting that heat degradation of amphenicols was accelerated in soybean sauce and was not protected in meat. Heat stability by drug and matrices was ranked as FF>TAP=CAP in water, FF=TAP>CAP in salt water, TAP> or =FF=CAP in soybean sauce, and TAP> or =FF=CAP in meat, indicating differential heat stability of amphenicols among the 3 drugs and in different matrices. In accordance with the less than 20% degradation, the MIC against Escherichia coli and Staphylococcus aureus did not change after 2h heating in water. A 5-min heating of amphenicols in water by microwave oven generated comparable percentage degradation to boiling in water bath for 30 min to 1h. Both CE and GC-MS analysis showed that heating of FF produced TAP but not FF amine as one of its breakdown products. In conclusion, despite close similarity in structure; amphenicols exhibited differential behavior toward heating degradation in solutions and protein matrices. Although higher degradations of amphenicols were observed in soybean sauce and meat, heating treatment may generate product with antimicrobial activity (FF to TAP), therefore, heating of amphenicol residues in food cannot always be assumed safe. Copyright (c) 2010 Elsevier B.V. All rights reserved.
NHEXAS PHASE I MARYLAND STUDY--PESTICIDES IN WATER ANALYTICAL RESULTS
The Pesticides in Water data set contains analytical results for measurements of up to 10 pesticides in 388 water samples over 80 households. One-liter samples of tap water were collected after a two-minute flush from the tap identified by the resident as that most commonly used...
Fristachi, Anthony; Xu, Ying; Rice, Glenn; Impellitteri, Christopher A; Carlson-Lynch, Heather; Little, John C
2009-11-01
The leaching of organotin (OT) heat stabilizers from polyvinyl chloride (PVC) pipes used in residential drinking water systems may affect the quality of drinking water. These OTs, principally mono- and di-substituted species of butyltins and methyltins, are a potential health concern because they belong to a broad class of compounds that may be immune, nervous, and reproductive system toxicants. In this article, we develop probability distributions of U.S. population exposures to mixtures of OTs encountered in drinking water transported by PVC pipes. We employed a family of mathematical models to estimate OT leaching rates from PVC pipe as a function of both surface area and time. We then integrated the distribution of estimated leaching rates into an exposure model that estimated the probability distribution of OT concentrations in tap waters and the resulting potential human OT exposures via tap water consumption. Our study results suggest that human OT exposures through tap water consumption are likely to be considerably lower than the World Health Organization (WHO) "safe" long-term concentration in drinking water (150 microg/L) for dibutyltin (DBT)--the most toxic of the OT considered in this article. The 90th percentile average daily dose (ADD) estimate of 0.034 +/- 2.92 x 10(-4)microg/kg day is approximately 120 times lower than the WHO-based ADD for DBT (4.2 microg/kg day).
Detection of ultra-low levels of DNA changes by drinking water: epidemiologically important finding.
Kumari, Parmila; Kamiseki, Meiko; Biyani, Manish; Suzuki, Miho; Nemoto, Naoto; Aita, Takuyo; Nishigaki, Koichi
2015-02-01
The safety of drinking water is essential to our health. In this context, the mutagenicity of water needs to be checked strictly. However, from the methodological limit, the lower concentration (less than parts per million) of mutagenicity could not be detected, though there have been of interest in the effect of less concentration mutagens. Here, we describe a highly sensitive mutation assay that detects mutagens at the ppb level, termed genome profiling-based mutation assay (GPMA). This consists of two steps; (i) Escherichia coli culture in the medium with/without mutagens and (ii) Genome profiling (GP) method (an integrated method of random PCR, temperature gradient gel electrophoresis and computer-aided normalization). Owing to high sensitivity of this method, very low concentration of mutagens in tap water could be directly detected without introducing burdensome concentration processes, enabling rapid measurement of low concentration samples. Less expectedly, all of the tap waters tested (22 samples) were shown to be significantly mutagenic while mineral waters were not. Resultantly, this article informs two facts that the GPMA method is competent to measure the mutagenicity of waters directly and the experimental results supported the former reports that the city tap waters contain very low level of mutagenicity reagent trihalomethanes. © The Authors 2014. Published by Oxford University Press on behalf of the Japanese Biochemical Society. All rights reserved.
Genuino, Homer C; Espino, Maria Pythias B
2012-04-01
Significant levels of potentially carcinogenic bromate were measured in chlorinated tap drinking water in Metropolitan Manila, Philippines, using an optimized ion-chromatographic method. This method can quantify bromate in water down to 4.5 μg l⁻¹ by employing a postcolumn reaction with acidic fuchsin and subsequent spectrophotometric detection. The concentration of bromate in tap drinking water samples collected from 21 locations in cities and municipalities within the 9-month study period ranged from 7 to 138 μg l⁻¹. The average bromate concentration of all tap drinking water samples was 66 μg l⁻¹ (n = 567), almost seven times greater than the current regulatory limit in the country. The levels of bromate in other water types were also determined to identify the sources of bromate found in the distribution lines and to further uncover contaminated sites. The concentration of bromate in water sourced from two rivers and two water treatment plants ranged from 15 to 80 and 12 to 101 μg l⁻¹, respectively. Rainwater did not contribute bromate in rivers but decreased bromate level by dilution. Groundwater and wastewater samples showed bromate concentrations as high as 246 and 342 μg l⁻¹, respectively. Bromate presence in tap drinking water can be linked to pollution in natural water bodies and the practice of using hypochlorite chemicals in addition to gaseous chlorine for water disinfection. This study established the levels, occurrence, and possible sources of bromate in local drinking water supplies.
Walia, Tarun; Abu Fanas, Salem; Akbar, Madiha; Eddin, Jamal; Adnan, Mohamad
2017-07-01
To assess fluoride concentration in drinking water which include tap water of 4 emirates - Abu Dhabi, Dubai, Sharjah and Ajman plus bottled water, commonly available soft drinks & juices in United Arab Emirates. Five different samples of tap water collected from each of the four emirates of UAE: Ajman, Sharjah, Abu Dhabi and Dubai; twenty-two brands of bottled water and fifteen brands of popular cold beverages, purchased from different supermarkets in U.A.E were tested using ion selective electrode method and the fluoride concentration was determined. The mean fluoride content of tap water samples was 0.14 mg F/L with a range of 0.04-0.3 mg F/L; with Ajman tap water samples showing the highest mean fluoride content of 0.3 mg F/L. The mean fluoride content for both bottled drinking water and beverages was 0.07 mg F/L with a range of 0.02-0.50 mg F/L and 0.04-0.1 mg F/L respectively. Majority (68.2%) of the bottled water are produced locally within U.A.E while a few (31.8%) are imported. The tap water, bottled water and beverages available in U.A.E show varying concentrations of fluoride, however none showed the optimal level necessary to prevent dental caries. Dental professionals in U.A.E should be aware of the fluoride concentrations before prescribing fluoride supplements to children.
Nakajima, Norihito; Nakano, Takashi; Harada, Fumiue; Taniguchi, Hiromasa; Yokoyama, Isao; Hirose, Jun; Daikoku, Eriko; Sano, Kouichi
2004-05-01
Tap water is one of the causative factors of hospital infections. We examined the disinfective potential of electrolysis and mechanism of disinfection, and clarified the disinfective effect of electrolysis on tap water contaminated with bacteria, and discussed its clinical applications. Tap waters artificially contaminated with Pseudomonas aeruginosa, Escherichia coli, Legionella pneumophila, and Staphylococcus aureus could be sterilized by electrolysis at 20-30 mA for 5 min. A high-density suspension (10(6) CFU/ml) of a spore forming bacterium, Bacillus subtilis was not completely sterilized by electrolysis at 50 mA up to 30 min, but a low-density suspension (10(5) CFU/ml) was totally sterilized by electrolysis at 50 mA for 5 min. Electrolyzed P. aeruginosa changed morphologically, that is, there was bleb formation on the cell wall and irregular aggregation of cytoplasmic small granules. Moreover, cytoplasmic enzyme, nitrate reductase, was inactivated by the electrolysis. On the other hand, genomic DNA of the electrolyzed bacteria was not degenerated, therefore, their DNA polymerase activity was not completely inactivated. Consequently, the major agent in electrolysis for bactericidal action was considered to be free chlorine, and the possible bactericidal mechanism was by destruction of bacterial membranes, followed by the aggregation of peripheral cytoplasmic proteins. Electrolysis of tap water for both disinfecting contaminating bacteria and increasing the disinfectant capacity was considered effective with some limitations, particularly against high-density contamination by spore-forming bacteria. In clinical settings, electrolysis of tap water is considered effective to disinfect water for hand washing in operation theatres, and bathing water for immunocompromised hosts.
Etale, Anita; Jobin, Marilou; Siegrist, Michael
2018-02-01
What drives consumers to choose bottled water instead of tap water where the latter is safe, accessible, costs far less, and in spite of its environmental impacts? This research investigates the influence of hitherto unexplored psychological drivers in an attempt to generate a more holistic understanding of the phenomenon, and strategies for designing more effective consumption reduction campaigns. Using data from an internet survey of Swiss and German respondents (N = 849) we investigated the role of, social norms, affect and image on water consumption. Results suggest that these psychological factors play a role in water consumption choice. Convenience was the only contextual predictor - the inconvenience of transporting bottled water has a negative effect on its consumption, and a positive effect on tap water consumption. Although concern about the effect of bottled water on the environment was not a significant predictor of tap water consumption, we found that for some people, a link exists between environmental concern and consumption choice. Ways through which consumers may be more effectively influenced towards environmentally-friendly consumption are discussed. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ishizuka, Akinori; Tanji, Masataka; Hayashi, Nobuatsu; Wakabayashi, Akihiro; Tatsumoto, Hideki; Hotta, Kunimoto
2006-12-01
For the long term storage of tap water, we developed a separate type of tank (5 m3) equipped with an electrolysis system to control bacterial growth. The electrolysis conditions using 20A direct current and a water flow rate of 10 L/min were capable of producing available chlorine (AC) at the rate of 5-8mg/min and raising the AC level of the stored tap water by about 0.2 mg/kg within 20-30 min The electrolyzed tap water with 0.2 mg/kg AC showed a capability per ml of killing 10(5)-10(6) cfu of bacteria such as Escherichia coli and Pseudomonas aeruginosa within 15 sec. A 6-month trial operation of the storage system with an automatic electrolysis control to keep AC level ranging 0.2-0.4 mg/kg demonstrated that the system worked well for the stored tap water in suppressing bacterial growth as well as in keeping good potable quality with reference to the 46 parameters specified for Japanese tap water. Actually, the electrolysis treatment was administered intermittently with an interval of about two weeks. Thus we believe the developed system has good potential to secure a potable water supply not only in the occasion of emergencies but also in countries having problems in the supply of safe drinking water.
Drinking water consumption patterns in Canadian communities (2001-2007).
Roche, S M; Jones, A Q; Majowicz, S E; McEwen, S A; Pintar, K D M
2012-03-01
A pooled analysis of seven cross-sectional studies from Newfoundland and Labrador, Waterloo and Hamilton Regions, Ontario and Vancouver, East Kootenay and Northern Interior Regions, British Columbia (2001 to 2007) was performed to investigate the drinking water consumption patterns of Canadians and to identify factors associated with the volume of tap water consumed. The mean volume of tap water consumed was 1.2 L/day, with a large range (0.03 to 9.0 L/day). In-home water treatment and interactions between age and gender and age and bottled water use were significantly associated with the volume of tap water consumed in multivariable analyses. Approximately 25% (2,221/8,916) of participants were classified as bottled water users, meaning that 75% or more of their total daily drinking water intake was bottled. Approximately 48.6% (4,307/8,799) of participants used an in-home treatment method to treat their tap water for drinking purposes. This study provides a broader geographic perspective and more current estimates of Canadian water consumption patterns than previous studies. The identified factors associated with daily water consumption could be beneficial for risk assessors to identify individuals who may be at greater risk of waterborne illness.
Ioannou, Panagiotis; Charisiadis, Pantelis; Andra, Syam S; Makris, Konstantinos C
2016-02-01
Non-iodo-containing trihalomethanes (TTHM) are frequently detected in chlorinated tap water and currently regulated against their carcinogenic potential. Iodinated THM (ITHM) may also form in disinfected with chlorine waters that are high in iodine content, but little is known about their magnitude and variability within the drinking-water pipe distribution network of urban areas. The main objective of this study was to determine the magnitude and variability of ITHM and TTHM levels and their corresponding daily intake estimates within the drinking water distribution systems of Limassol and Nicosia cities of Cyprus, using tap samples collected from individual households (n=37). In Limassol, mean household tap water ITHM and TTHM levels was 0.58 and 38 μg L(-1), respectively. Dichloroiodomethane (DCIM) was the dominant species of the two measured ITHM compounds accounting for 77% of total ITHM and in the range of 0.032 and 1.65 μg L(-1). The range of DCIM concentrations in Nicosia tap water samples was narrower (0.032 - 0.848 μg L(-1)). Mean total iodine concentration in tap water samples from the seaside city of Limassol was 15 μg L(-1) and approximately twice to those observed in samples from the mainland Nicosia city. However, iodine concentrations did not correlate with the ITHM levels. The calculated chronic daily intake rates of ITHM were low when compared with those of TTHM, but because of their widespread occurrence in tap water and their enhanced mammalian cell toxicity, additional research is warranted to assess the magnitude and variability of human ITHM exposures. Copyright © 2015 Elsevier B.V. All rights reserved.
33 CFR 165.1710 - Port Valdez and Valdez Narrows, Valdez, Alaska-security zones.
Code of Federal Regulations, 2010 CFR
2010-07-01
... following areas are security zones: (1) Trans-Alaska Pipeline (TAPS) Valdez Terminal complex (Terminal), Valdez, Alaska and TAPS tank vessels. All waters enclosed within a line beginning on the southern... TAPS tank vessel maneuvering to approach, moor, unmoor or depart the TAPS Terminal or transiting...
Anthropogenic contamination of tap water, beer, and sea salt
2018-01-01
Plastic pollution has been well documented in natural environments, including the open waters and sediments within lakes and rivers, the open ocean and even the air, but less attention has been paid to synthetic polymers in human consumables. Since multiple toxicity studies indicate risks to human health when plastic particles are ingested, more needs to be known about the presence and abundance of anthropogenic particles in human foods and beverages. This study investigates the presence of anthropogenic particles in 159 samples of globally sourced tap water, 12 brands of Laurentian Great Lakes beer, and 12 brands of commercial sea salt. Of the tap water samples analyzed, 81% were found to contain anthropogenic particles. The majority of these particles were fibers (98.3%) between 0.1–5 mm in length. The range was 0 to 61 particles/L, with an overall mean of 5.45 particles/L. Anthropogenic debris was found in each brand of beer and salt. Of the extracted particles, over 99% were fibers. After adjusting for particles found in lab blanks for both salt and beer, the average number of particles found in beer was 4.05 particles/L with a range of 0 to 14.3 particles/L and the average number of particles found in each brand of salt was 212 particles/kg with a range of 46.7 to 806 particles/kg. Based on consumer guidelines, our results indicate the average person ingests over 5,800 particles of synthetic debris from these three sources annually, with the largest contribution coming from tap water (88%). PMID:29641556
Occurrence of nitrosamines and their precursors in drinking water systems around mainland China.
Bei, Er; Shu, Yuanyuan; Li, Shixiang; Liao, Xiaobin; Wang, Jun; Zhang, Xiaojian; Chen, Chao; Krasner, Stuart
2016-07-01
N-Nitrosamines (NAs) in drinking water have attracted considerable attention in recent years due to their high carcinogenicity, frequent occurrence, and their potential regulation. During the past three years, we have collected about 164 water samples of finished water, tap water, and source water from 23 provinces, 44 cities from large cities to small towns, and 155 sampling points all over China. The occurrence of NAs in the finished and tap water was much higher in China than that in the U.S. Nine NAs were measured and NDMA had the highest concentration. The occurrence of NDMA was in 33% of the finished waters of water treatment plants and in 41% of the tap waters. The average NDMA concentration in finished and tap waters was 11 and 13 ng/L, respectively. Formation potentials (FPs) of source waters were examined with an average NDMA FP of 66 ng/L. Large variations in NA occurrence were observed geographically in China and temporally in different seasons. The Yangtze River Delta area, one sub-area in East China, had the highest concentrations of NAs, where the average NDMA concentrations in the finished and tap water were 27 and 28.5 ng/L, respectively, and the average NDMA FP in the source water was 204 ng/L. NA control may be achieved by applying breakpoint free chlorination and/or advanced treatment of ozone - granular activated carbon process to remove the NA precursors before disinfection. Copyright © 2016 Elsevier Ltd. All rights reserved.
Birkhäuser, Frédéric D; Zehnder, Pascal; Roth, Beat; Schürch, Leander; Ochsner, Katharina; Willener, Rita; Thalmann, George N; Burkhard, Fiona C; Studer, Urs E
2011-04-01
Continent catheterizable ileal pouches require regular irrigations to reduce the risk of bacteriuria and urinary tract infections (UTIs). Our aim was to compare the UTI rate, patient friendliness, and costs of standard sterile irrigation versus irrigation with tap water. Twenty-three patients participated in a prospective randomized two-arm crossover single-center trial. Aseptic intermittent self-catheterization (ISC) combined with sterile sodium chloride (NaCl) 0.9% irrigation was compared with clean ISC and irrigation with tap water (H(2)O) during two study periods of 90 d each. Patients underwent daily pouch irrigations with NaCl 0.9% solution or tap water. Urine nitrite dipstick tests were evaluated daily; urine culture (UC) and patient friendliness were evaluated monthly. Costs were documented. A total of 3916 study days with nitrite testing and irrigation were analyzed, 1876 (48%) in the NaCl arm and 2040 (52%) in the H(2)O arm. In the NaCl arm, 418 study days (22%) with nitrite-positive dipsticks were recorded, 219 d (11%) in the H(2)O arm, significantly fewer (p=0.01). Of the 149 UCs, 96 (64%) were positive, 48 in each arm, revealing a total of 16 different germs. All patients preferred the H(2)O method. Monthly costs were up to 20 times lower in the H(2)O arm. Pouch irrigation with sterile NaCl 0.9% solution and tap water had comparable rates of positive UC. Irrigation with tap water significantly lowered the incidence of nitrite-positive study days and was substantially less costly and more patient friendly than NaCl irrigation. We therefore recommend the use of tap water (or bottled water) instead of sterile NaCl 0.9% solution for daily irrigation of continent catheterizable ileal pouches. Australian New Zealand Clinical Trials Registry, ACTRN12610000618055, http://www.ANZCTR.org.au/ACTRN12610000618055.aspx. Copyright © 2011 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Momtaz, Hassan; Dehkordi, Farhad Safarpoor; Rahimi, Ebrahim; Asgarifar, Amin
2013-06-07
The quality of drinking water has an important role in human infection and disease. This study was aimed at comparing polymerase chain reaction and culture in detecting Escherichia coli, Salmonella species and Vibrio cholera in tape water and bottled drinking water in various seasons in Isfahan province, Iran. A total of 448 water samples from tap water and bottled mineral water were taken over 6 months, from July 2010 to December 2010, and after filtration, samples were examined by culture and polymerase chain reaction methods for detection of Escherichia coli, Salmonella species, and Vibrio cholerae. The culture method showed that 34 (7.58%), 4 (0.89%) and 3 (0.66%) of all 448 water samples were positive for Escherichia coli, Salmonella species, and Vibrio cholera, respectively. The uidA gene from Escherichia coli, IpaB gene from Salmonella species, and epsM gene from Vibrio cholera were detected in 38 (26.38%), 5 (3.47%), and 3 (2.08%) of 144 tap-water samples, respectively. Escherichia coli was detected in 8 (2.63%) of 304 samples of bottled drinking water from 5 companies. The water of southern part of Isfahan and company 5 had the highest prevalence of bacteria. The Escherichia coli water contamination was significantly higher (P < 0.05) in the hot seasons (July-August) than cold (November-December) seasons and in company 5 than other companies. There were significant differences (P < 0.05) for the prevalence of bacteria between the tap waters of southern part and tap waters of central part of Isfahan. This study showed that the polymerase chain reaction assays can be an extremely accurate, fast, safe, sensitive and specific approach to monitor drinking water quality from purification facilities and bottled water companies. Also, our study confirmed the presence of Escherichia coli, Salmonella species, and Vibrio cholerae as water-borne pathogens in tap water and bottled drinking water of Isfahan, Iran. The present study showed the important public health problem in Isfahan, Iran.
2013-01-01
Background The quality of drinking water has an important role in human infection and disease. This study was aimed at comparing polymerase chain reaction and culture in detecting Escherichia coli, Salmonella species and Vibrio cholera in tape water and bottled drinking water in various seasons in Isfahan province, Iran. Methods A total of 448 water samples from tap water and bottled mineral water were taken over 6 months, from July 2010 to December 2010, and after filtration, samples were examined by culture and polymerase chain reaction methods for detection of Escherichia coli, Salmonella species, and Vibrio cholerae. Results The culture method showed that 34 (7.58%), 4 (0.89%) and 3 (0.66%) of all 448 water samples were positive for Escherichia coli, Salmonella species, and Vibrio cholera, respectively. The uidA gene from Escherichia coli, IpaB gene from Salmonella species, and epsM gene from Vibrio cholera were detected in 38 (26.38%), 5 (3.47%), and 3 (2.08%) of 144 tap-water samples, respectively. Escherichia coli was detected in 8 (2.63%) of 304 samples of bottled drinking water from 5 companies. The water of southern part of Isfahan and company 5 had the highest prevalence of bacteria. The Escherichia coli water contamination was significantly higher (P < 0.05) in the hot seasons (July-August) than cold (November-December) seasons and in company 5 than other companies. There were significant differences (P < 0.05) for the prevalence of bacteria between the tap waters of southern part and tap waters of central part of Isfahan. Conclusions This study showed that the polymerase chain reaction assays can be an extremely accurate, fast, safe, sensitive and specific approach to monitor drinking water quality from purification facilities and bottled water companies. Also, our study confirmed the presence of Escherichia coli, Salmonella species, and Vibrio cholerae as water-borne pathogens in tap water and bottled drinking water of Isfahan, Iran. The present study showed the important public health problem in Isfahan, Iran. PMID:23742181
Sayed, M A M; Downing, J
2011-01-01
Exposing broilers to a high temperature increases water and electrolyte K(+) and Na(+) excretion, which negatively affects the heat dissipation capacity and acid-base homeostasis, resulting in losses in growth performance. In this experiment, the efficacy of providing oral rehydration therapy and betaine on growth performance, acid-base balance, and water and electrolyte retention was evaluated. A total of 432 one-day-old broiler chicks (Cobb) were allocated to 72 metabolic cages and reared to 31 d of age under standard conditions. From 32 to 41 d of age, chicks were exposed to heat stress (ambient temperature, 32°C) and high RH (80 to 100% RH) for 9 h daily. The ameliorative effects of a 3 × 3 factorial array of treatments administered via drinking water were evaluated in 8 replicates of 6 chicks per cage for each treatment. Two oral rehydration therapy (ORT) fluids, based on either citrate or bicarbonate salts, were added to tap water. In addition, betaine was added to tap water at an inclusion rate of 0, 500, or 1,000 mg/L to complete the array of 9 liquid-based treatments. Growth performance was assessed at 32, 35, and 41 d of age. From 32 to 35 d of age, chicks receiving ORT fluids exhibited improved growth performance, water balance, and electrolyte (K(+), Na(+)) retention. In addition, the physiological response to stress was attenuated, as indicated by lower heterophil-to-lymphocyte ratios and blood glucose concentrations relative to the negative controls. The addition of betaine at an inclusion rate of 500 mg/L improved BW gain. From d 36 to 41, treatments did not significantly influence growth performance, which suggests that chicks receiving tap water were able to compensate and adapt to the heat-stress conditions. The results demonstrate that the beneficial effects of providing ORT fluids and 500 mg of betaine/L were observed only during the first 4 d of heat exposure. After this period, adaptation to the heat appears to occur, and none of the treatments was successful in improving growth performance.
NHEXAS PHASE I MARYLAND STUDY--METALS IN WATER ANALYTICAL RESULTS
The Metals in Water data set contains analytical results for measurements of up to 11 metals in 400 water samples over 80 households. One-liter samples of tap water were collected after a two minute flush from the tap identified by the resident as that most commonly used for dri...
Occurrence of nonylphenol and bisphenol A in household water pipes made of different materials.
Cheng, Yang-Chen; Chen, Huei-Wen; Chen, Wen-Ling; Chen, Chia-Yang; Wang, Gen-Shuh
2015-10-01
We assessed the occurrence of nonylphenol (NP) and bisphenol A (BPA) in tap water supplied through polyvinyl chloride (PVC), stainless steel, and galvanized pipes. Water samples were collected from selected households in Taipei and Kaohsiung (Northern and Southern Taiwan, respectively) in different seasons to elucidate the effects of pipeline materials and ambient temperatures on NP and BPA concentrations in tap water. We detected higher concentrations of NP in tap water from households using PVC pipes (64-195 ng/L) than from those using stainless steel pipes (17-44 ng/L) and galvanized pipes (27-96 ng/L). To verify that water can absorb NP and BPA from PVC pipes, we sealed Milli-Q and tap water in PVC and stainless steel pipes to assess the potential release of NP and BPA from the pipes into the water. Both NP and BPA concentrations initially increased with contact time in the PVC pipes, and the concentration profiles during the retention appeared to be more strongly affected by ambient temperatures. Concentration variations in the stainless steel pipes were smaller than those in the PVC pipes.
Murai, K; Okano, M; Kuramitz, H; Hata, N; Kawakami, T; Taguchi, S
2008-01-01
The pollution of tap water and rain water with formaldehyde in Toyama Pref., Japan was investigated by means of a simple, rapid and cost-effective visual colorimetry developed by us. The levels of formaldehyde in three tap waters from different sources of dams on mountainside and a well-water pumped in urban area in Toyama Pref. were lower than 0.01 mg L(-1) that was the detection limit of the colorimetry. On the other hand, rain waters were seriously polluted with formaldehyde. Rain waters were sampled from three different sites (urban area, top of hill and industrial area) in Toyama Pref. from autumn to winter in 2006. The levels of formaldehyde in the rain waters ranged from 0.07 to 0.30 mg L(-1). The analytical results by the visual colorimetry were in good agreement with those obtained by GC-MS method. It was confirmed that the colorimetry is excellent for practical use for the determination of formaldehyde. It must be concerned about the pollution of rainwater with formaldehyde, when rain water is applied for tap water and miscellaneous purpose. Copyright IWA Publishing 2008.
Bédard, Emilie; Lévesque, Simon; Martin, Philippe; Pinsonneault, Linda; Paranjape, Kiran; Lalancette, Cindy; Dolcé, Charles-Éric; Villion, Manuela; Valiquette, Louis; Faucher, Sébastien P; Prévost, Michèle
2016-12-01
OBJECTIVE To determine the source of a Legionella pneumophila serogroup 5 nosocomial outbreak and the role of the heat exchanger installed on the hot water system within the previous year. SETTING A 400-bed tertiary care university hospital in Sherbrooke, Canada. METHODS Hot water samples were collected and cultured for L. pneumophila from 25 taps (baths and sinks) within wing A and 9 taps in wing B. Biofilm (5) and 2 L water samples (3) were collected within the heat exchangers for L. pneumophila culture and detection of protists. Sequence-based typing was performed on strain DNA extracts and pulsed-field gel electrophoresis patterns were analyzed. RESULTS Following 2 cases of hospital-acquired legionellosis, the hot water system investigation revealed a large proportion of L. pneumophila serogroup 5 positive taps (22/25 in wing A and 5/9 in wing B). High positivity was also detected in the heat exchanger of wing A in water samples (3/3) and swabs from the heat exchanger (4/5). The outbreak genotyping investigation identified the hot water system as the source of infections. Genotyping results revealed that all isolated environmental strains harbored the same related pulsed-field gel electrophoresis pattern and sequence-based type. CONCLUSIONS Two cases of hospital-acquired legionellosis occurred in the year following the installation of a heat exchanger to preheat hospital hot water. No cases were reported previously, although the same L. pneumophila strain was isolated from the hot water system in 1995. The heat exchanger promoted L. pneumophila growth and may have contributed to confirmed clinical cases. Infect. Control Hosp. Epidemiol. 2016;1475-1480.
Water quality monitoring records for estimating tap water arsenic and nitrate: a validation study.
Searles Nielsen, Susan; Kuehn, Carrie M; Mueller, Beth A
2010-01-28
Tap water may be an important source of exposure to arsenic and nitrate. Obtaining and analyzing samples in the context of large studies of health effects can be expensive. As an alternative, studies might estimate contaminant levels in individual homes by using publicly available water quality monitoring records, either alone or in combination with geographic information systems (GIS). We examined the validity of records-based methods in Washington State, where arsenic and nitrate contamination is prevalent but generally observed at modest levels. Laboratory analysis of samples from 107 homes (median 0.6 microg/L arsenic, median 0.4 mg/L nitrate as nitrogen) served as our "gold standard." Using Spearman's rho we compared these measures to estimates obtained using only the homes' street addresses and recent and/or historical measures from publicly monitored water sources within specified distances (radii) ranging from one half mile to 10 miles. Agreement improved as distance decreased, but the proportion of homes for which we could estimate summary measures also decreased. When including all homes, agreement was 0.05-0.24 for arsenic (8 miles), and 0.31-0.33 for nitrate (6 miles). Focusing on the closest source yielded little improvement. Agreement was greatest among homes with private wells. For homes on a water system, agreement improved considerably if we included only sources serving the relevant system (rho = 0.29 for arsenic, rho = 0.60 for nitrate). Historical water quality databases show some promise for categorizing epidemiologic study participants in terms of relative tap water nitrate levels. Nonetheless, such records-based methods must be used with caution, and their use for arsenic may be limited.
Zhang, Chao; She, Yongxin; Li, Tengfei; Zhao, Fengnian; Jin, Maojun; Guo, Yirong; Zheng, Lufei; Wang, Shanshan; Jin, Fen; Shao, Hua; Liu, Haijin; Wang, Jing
2017-12-01
An electrochemical sensor based on molecularly imprinted polypyrrole (MIPPy) was developed for selective and sensitive detection of the herbicide glyphosate (Gly) in cucumber and tap water samples. The sensor was prepared via synthesis of molecularly imprinted polymers on a gold electrode in the presence of Gly as the template molecule and pyrrole as the functional monomer by cyclic voltammetry (CV). The sensor preparation conditions including the ratio of template to functional monomers, number of CV cycles in the electropolymerization process, the method of template removal, incubation time, and pH were optimized. Under the optimal experimental conditions, the DPV peak currents of hexacyanoferrate/hexacyanoferrite changed linearly with Gly concentration in the range from 5 to 800 ng mL -1 , with a detection limit of 0.27 ng mL -1 (S/N = 3). The sensor was used to detect the concentration of Gly in cucumber and tap water samples, with recoveries ranging from 72.70 to 98.96%. The proposed sensor showed excellent selectivity, good stability and reversibility, and could detect the Gly in real samples rapidly and sensitively. Graphical abstract Schematic illustration of the experimental procedure to detect Gly using the MIPPy electrode.
Root distribution of Nitraria sibirica with seasonally varying water sources in a desert habitat.
Zhou, Hai; Zhao, Wenzhi; Zheng, Xinjun; Li, Shoujuan
2015-07-01
In water-limited environments, the water sources used by desert shrubs are critical to understanding hydrological processes. Here we studied the oxygen stable isotope ratios (δ (18)O) of stem water of Nitraria sibirica as well as those of precipitation, groundwater and soil water from different layers to identify the possible water sources for the shrub. The results showed that the shrub used a mixture of soil water, recent precipitation and groundwater, with shallow lateral roots and deeply penetrating tap (sinker) roots, in different seasons. During the wet period (in spring), a large proportion of stem water in N. sibirica was from snow melt and recent precipitation, but use of these sources declined sharply with the decreasing summer rain at the site. At the height of summer, N. sibirica mainly utilized deep soil water from its tap roots, not only supporting the growth of shoots but also keeping the shallow lateral roots well-hydrated. This flexibility allowed the plants to maintain normal metabolic processes during prolonged periods when little precipitation occurs and upper soil layers become extremely dry. With the increase in precipitation that occurs as winter approaches, the percentage of water in the stem base of a plant derived from the tap roots (deep soil water or ground water) decreased again. These results suggested that the shrub's root distribution and morphology were the most important determinants of its ability to utilize different water sources, and that its adjustment to water availability was significant for acclimation to the desert habitat.
Perfluoroalkyl acids (PFAAs) in the Pra and Kakum River basins and associated tap water in Ghana.
Essumang, David K; Eshun, Albert; Hogarh, Jonathan N; Bentum, John K; Adjei, Joseph K; Negishi, Junya; Nakamichi, Shihori; Habibullah-Al-Mamun, Md; Masunaga, Shigeki
2017-02-01
Perfluoroalkyl acids (PFAAs) are persistent environmental pollutants that have been detected in various media including human serum. Due to concerns regarding their bioaccumulation and possible negative health effects, an understanding of routes of human exposure is necessary. PFAAs are recalcitrant in many water treatment processes, making drinking water a potential source of human exposure. This study presents the first report on contamination from PFAAs in river and drinking water in Ghana. The targeted PFAAs were perfluoroalkyl carboxylic acids (PFCAs) with C 4-14 carbon chain and perfluoroalkane sulphonic acids (PFSAs) with C 6, 8, 10 . Five PFAA congeners - PFOA, PFOS, PFHxA, PFDA and PFPeA - were commonly detected in river and tap water. The mean concentrations of ∑PFAAs in the Kakum and Pra Rivers were 281 and 398ng/L, while tap water (supplied from the treatment of water from those rivers) contained concentrations of 197 and 200ng/L, respectively. PFOA and PFOS constituted about 99% of the ∑PFAAs. The risk quotient (RQ) attributed to drinking of tap water was estimated at 1.01 and 1.74 for PFOA and PFOS, respectively. For a country that has not produced these compounds, the RQs were unexpectedly high, raising concerns particularly about contamination from such emerging pollutants in local water sources. The study revealed limitations of local tap water treatment in getting rid of these emerging pollutants. Copyright © 2016 Elsevier B.V. All rights reserved.
Efficacy of home washing methods in controlling surface microbial contamination on fresh produce.
Kilonzo-Nthenge, Agnes; Chen, Fur-Chi; Godwin, Sandria L
2006-02-01
Much effort has been focused on sanitation of fresh produce at the commercial level; however, few options are available to the consumer. The purpose of this study was to determine the efficacy of different cleaning methods in reducing bacterial contamination on fresh produce in a home setting. Lettuce, broccoli, apples, and tomatoes were inoculated with Listeria innocua and then subjected to combinations of the following cleaning procedures: (i) soak for 2 min in tap water, Veggie Wash solution, 5% vinegar solution, or 13% lemon solution and (ii) rinse under running tap water, rinse and rub under running tap water, brush under running tap water, or wipe with wet/dry paper towel. Presoaking in water before rinsing significantly reduced bacteria in apples, tomatoes, and lettuce, but not in broccoli. Wiping apples and tomatoes with wet or dry paper towel showed lower bacterial reductions compared with soaking and rinsing procedures. Blossom ends of apples were more contaminated than the surface after soaking and rinsing; similar results were observed between flower section and stem of broccoli. Reductions of L. innocua in both tomatoes and apples (2.01 to 2.89 log CFU/g) were more than in lettuce and broccoli (1.41 to 1.88 log CFU/g) when subjected to same washing procedures. Reductions of surface contamination of lettuce after soaking in lemon or vinegar solutions were not significantly different (P > 0.05) from lettuce soaking in cold tap water. Therefore, educators and extension workers might consider it appropriate to instruct consumers to rub or brush fresh produce under cold running tap water before consumption.
Filipovic, Marko; Berger, Urs
2015-06-01
Wastewater treatment plants (WWTP) have been suggested to be one of the major pathways of perfluoroalkyl acids (PFAAs) from the technosphere to the aquatic environment. The origin of PFAAs in WWTP influents is either from current primary emissions or a result of recirculation of PFAAs that have been residing and transported in the environment for several years or decades. Environmental recirculation can then occur when PFAAs from the environment enter the wastewater stream in, e.g., tap water. In this study 13 PFAAs and perfluorooctane sulfonamide were analyzed in tap water as well as WWTP influent, effluent and sludge from three Swedish cities: Bromma (in the metropolitan area of Stockholm), Bollebygd and Umeå. A mass balance of the WWTPs was assembled for each PFAA. Positive mass balances were observed for PFHxA and PFOA in all WWTPs, indicating the presence of precursor compounds in the technosphere. With regard to environmental recirculation, tap water was an important source of PFAAs to the Bromma WWTP influent, contributing >40% for each quantified sulfonic acid and up to 30% for the carboxylic acids. The PFAAs in tap water from Bollebygd and Umeå did not contribute significantly to the PFAA load in the WWTP influents. Our results show that in order to estimate current primary emissions from the technosphere, it may be necessary to correct the PFAA emission rates in WWTP effluents for PFAAs present in tap water, especially in the case of elevated levels in tap water. Copyright © 2014 Elsevier Ltd. All rights reserved.
Su, Hao-Chang; Liu, You-Sheng; Pan, Chang-Gui; Chen, Jun; He, Liang-Ying; Ying, Guang-Guo
2018-03-01
As emerging contaminants, antibiotic resistance genes (ARGs) have become a public concern. This study aimed to investigate the occurrence and diversity of ARGs, and variation in the composition of bacterial communities in source water, drinking water treatment plants, and tap water in the Pearl River Delta region, South China. Various ARGs were present in the different types of water. Among the 27 target ARGs, floR and sul1 dominated in source water from three large rivers in the region. Pearson correlation analysis suggested that sul1, sul2, floR, and cmlA could be potential indicators for ARGs in water samples. The total abundance of the detected ARGs in tap water was much lower than that in source water. Sand filtration and sedimentation in drinking water treatment plants could effectively remove ARGs; in contrast, granular activated carbon filtration increased the abundance of ARGs. It was found that Pseudomonas may be involved in the proliferation and dissemination of ARGs in the studied drinking water treatment system. Bacteria and ARGs were still present in tap water after treatment, though they were significantly reduced. More research is needed to optimize the water treatment process for ARG removal. Copyright © 2017 Elsevier B.V. All rights reserved.
Children's drinking water: parental preferences and implications for fluoride exposure.
Sriraman, Natasha K; Patrick, Patricia A; Hutton, Kara; Edwards, Karen S
2009-01-01
The purposes of this study were to: describe children's drinking water sources; determine if any demographic factors are associated with water choice; describe parents' reasons for selecting bottled water; and determine parents' ability to provide enough information about their drinking water for providers to assess children's fluoride exposure. Subjects were parents of children 6 months to 15-years-old. A questionnaire was verbally administered in English or Spanish. Chi-square analyses were used to evaluate associations among study variables. Of 194 parents, 134 (69%) gave their children bottled water either exclusively or with tap water. Bottled water use was not significantly associated with the primary source of tap water, parent's education level, or household income. Reasons for giving children bottled water included: fear of contaminants in tap water; taste and/or smell of tap water; and convenience of bottled water. For parents using bottled water, over 65% did not know the brand's fluoride content. Barriers to an accurate fluoride assessment include frequent bottled water use and parental uncertainty about its fluoride content. By initiating communication with parents and educating them about fluoride sources, health care and dental providers may be able to better evaluate the adequacy of children's fluoride exposure and decide whether fluoride supplementation is necessary.
Donohue, Maura J; O'Connell, Katharine; Vesper, Stephen J; Mistry, Jatin H; King, Dawn; Kostich, Mitch; Pfaller, Stacy
2014-03-18
In the United States, 6,868 cases of legionellosis were reported to the Center for Disease Control and Prevention in 2009-2010. Of these reports, it is estimated that 84% are caused by the microorganism Legionella pneumophila Serogroup (Sg) 1. Legionella spp. have been isolated and recovered from a variety of natural freshwater environments. Human exposure to L. pneumophila Sg1 may occur from aerosolization and subsequent inhalation of household and facility water. In this study, two primer/probe sets (one able to detect L. pneumophila and the other L. pneumophila Sg1) were determined to be highly sensitive and selective for their respective targets. Over 272 water samples, collected in 2009 and 2010 from 68 public and private water taps across the United States, were analyzed using the two qPCR assays to evaluate the incidence of L. pneumophila Sg1. Nearly half of the taps showed the presence of L. pneumophila Sg1 in one sampling event, and 16% of taps were positive in more than one sampling event. This study is the first United States survey to document the occurrence and colonization of L. pneumophila Sg1 in cold water delivered from point of use taps.
NASA Astrophysics Data System (ADS)
Shimodozono, Megumi; Matsumoto, Shuji; Ninomiya, Koji; Miyata, Ryuji; Ogata, Atsuko; Etoh, Seiji; Watanabe, Satoshi; Kawahira, Kazumi
2012-09-01
To preliminarily assess the acute effects of a single warm -water bath (WWB) on serum adipokine activity, we measured serum adiponectin, leptin and other metabolic profiles before, immediately after and 30 minutes after WWB in seven healthy male volunteers (mean age, 39.7 ± 6.0 years; mean body mass index, 21.6 ± 1.8 kg/m2). The subjects were immersed in tap water at 41°C for 10 minutes. Two weeks later, the same subjects underwent a single WWB with a bath additive that included inorganic salts and carbon dioxide (WWB with ISCO2) by the same protocol as for the first WWB. Leptin levels significantly increased immediately after WWB with tap water and ISCO2 (both P < 0.05), and remained significantly higher than those at baseline even 30 minutes after WWB with tap water ( P < 0.05). Adiponectin levels showed a slight, but not significant, increase both immediately after and 30 minutes after WWB with tap water or ISCO2. Some parameters, such as serum total cholesterol, red blood cell count, hemoglobin and hematocrit significantly increased immediately after WWB with tap water or ISCO2 (all P < 0.05), but they all returned to the baseline levels 30 minutes after bathing under both conditions. The sublingual temperature rose significantly after 10 minutes of WWB with tap water (0.96 ± 0.16°C relative to baseline, P < 0.01) and after the same duration of WWB with ISCO2 (1.24 ± 0.34°C relative to baseline, P < 0.01). These findings suggest that a single WWB at 41°C for 10 minutes may modulate leptin and adiponectin profiles in healthy men.
Changes in mouse gut bacterial community in response to different types of drinking water.
Dias, Marcela F; Reis, Mariana P; Acurcio, Leonardo B; Carmo, Anderson O; Diamantino, Cristiane F; Motta, Amanda M; Kalapothakis, Evanguedes; Nicoli, Jacques R; Nascimento, Andréa M A
2018-04-01
Gut microbiota exerts a fundamental role on host physiology, and how extrinsic perturbations influence its composition has been increasingly examined. However, the effect of drinking water on gut microbiota is still poorly understood. In this study, we explored the response of mouse gut bacterial community (fecal and mucosa-adhered) to the ingestion of different types of drinking water. The experimental cohort was divided according to different water sources into four groups of mice that consumed autoclaved tap water (control group), water collected directly from a drinking water treatment plant, tap water, and commercial bottled mineral water. Differences among groups were observed, especially related to control group, which exhibited the smallest intra-group variation, and the largest distance from test groups on the last experimental day. Clinically important taxa, such as Acinetobacter and Staphylococcus, increased in feces of mice that drank tap water and in mucosa-adhered samples of animals from disinfected and tap water groups. Furthermore, statistical analyses showed that both time elapsed between samplings and water type significantly influenced the variation observed in the samples. Our results reveal that drinking water potentially affects gut microbiota composition. Additionally, the increase of typical drinking water clinically relevant and antibiotic resistance-associated bacteria in gut microbiota is a cause of concern. Copyright © 2017 Elsevier Ltd. All rights reserved.
Casanova, Lisa M; Walters, Adam; Naghawatte, Ajith; Sobsey, Mark D
2012-11-01
There is little information about continued use of point-of-use technologies after disaster relief efforts. After the 2004 tsunami, the Red Cross distributed ceramic water filters in Sri Lanka. This study determined factors associated with filter disuse and evaluate the quality of household drinking water. A cross-sectional survey of water sources and treatment, filter use and household characteristics was administered by in-person oral interview, and household water quality was tested. Multivariable logistic regression was used to model probability of filter non-use. At the time of survey, 24% of households (107/452) did not use filters; the most common reason given was breakage (42%). The most common household water sources were taps and wells. Wells were used by 45% of filter users and 28% of non-users. Of households with taps, 75% had source water Escherichia coli in the lowest World Health Organisation risk category (<1/100 ml), vs. only 30% of households reporting wells did. Tap households were approximately four times more likely to discontinue filter use than well households. After 2 years, 24% of households were non-users. The main factors were breakage and household water source; households with taps were more likely to stop use than households with wells. Tap water users also had higher-quality source water, suggesting that disuse is not necessarily negative and monitoring of water quality can aid decision-making about continued use. To promote continued use, disaster recovery filter distribution efforts must be joined with capacity building for long-term water monitoring, supply chains and local production. © 2012 Blackwell Publishing Ltd.
Lin, Wenfang; Yu, Zhisheng; Chen, Xi; Liu, Ruyin; Zhang, Hongxun
2013-09-01
Microorganism in drinking water distribution system may colonize in biofilms. Bacterial 16S rRNA gene diversities were analyzed in both water and biofilms grown on taps with three different materials (polyvinyl chloride (PVC), stainless steel, and cast iron) from a local drinking water distribution system. In total, five clone libraries (440 sequences) were obtained. The taxonomic composition of the microbial communities was found to be dominated by members of Proteobacteria (65.9-98.9 %), broadly distributed among the classes Alphaproteobacteria, Betaproteobacteria, and Gammaproteobacteria. Other bacterial groups included Firmicutes, Acidobacteria, Bacteroidetes, Cyanobacteria, and Deinococcus-Thermus. Moreover, a small proportion of unclassified bacteria (3.5-10.6 %) were also found. This investigation revealed that the bacterial communities in biofilms appeared much more diversified than expected and more care should be taken to the taps with high bacterial diversity. Also, regular monitor of outflow water would be useful as potentially pathogenic bacteria were detected. In addition, microbial richness and diversity in taps ranked in the order as: PVC < stainless steel < cast iron. All the results interpreted that PVC would be a potentially suitable material for use as tap component in drinking water distribution system.
Zhang, Hai-Han; Chen, Sheng-Nan; Huang, Ting-Lin; Shang, Pan-Lu; Yang, Xiao; Ma, Wei-Xing
2015-01-01
The growth of the bacterial community harbored in indoor drinking water taps is regulated by external environmental factors, such as indoor temperature. However, the effect of indoor heating on bacterial regrowth associated with indoor drinking water taps is poorly understood. In the present work, flow cytometry and community-level sole-carbon-source utilization techniques were combined to explore the effects of indoor heating on water bacterial cell concentrations and community carbon metabolic profiles in building tap pipes during the winter season. The results showed that the temperature of water stagnated overnight (“before”) in the indoor water pipes was 15–17 °C, and the water temperature decreased to 4–6 °C after flushing for 10 min (“flushed”). The highest bacterial cell number was observed in water stagnated overnight, and was 5–11 times higher than that of flushed water. Meanwhile, a significantly higher bacterial community metabolic activity (AWCD590nm) was also found in overnight stagnation water samples. The significant “flushed” and “taps” values indicated that the AWCD590nm, and bacterial cell number varied among the taps within the flushed group (p < 0.01). Heatmap fingerprints and principle component analyses (PCA) revealed a significant discrimination bacterial community functional metabolic profiles in the water stagnated overnight and flushed water. Serine, threonine, glucose-phosphate, ketobutyric acid, phenylethylamine, glycerol, putrescine were significantly used by “before” water samples. The results suggested that water stagnated at higher temperature should be treated before drinking because of bacterial regrowth. The data from this work provides useful information on reasonable utilization of drinking water after stagnation in indoor pipes during indoor heating periods. PMID:26516885
Copper in household drinking water in the city of Zagreb, Croatia.
Pizent, Alica; Butković, Sanja
2010-09-01
Copper concentration was estimated in tap water samples obtained from 70 households in Zagreb, serviced by a public water supply system. First-draw and flushed samples of tap water were collected in the morning and total copper concentration was determined by graphite furnace atomic absorption spectrometry with Zeeman-effect background correction. We also estimated the contribution of plumbing material to copper concentrations in tap water. In households with copper pipes, median and range copper values were 310 μg L-1 [(27 to 632) μg L-1] in first-draw samples and 16 μg L-1 [(5 to 52) μg L-1] in flushed samples. Corresponding values for households with galvanised pipes were 140 μg L-1 [(11 to 289) μg L-1] and 8 μg L-1 [(1 to 42) μg L-1], respectively. Copper concentrations in household tap water in Zagreb were far below the proposed safe limits set by the Croatian and WHO regulations and EPA standards, and drinking water in Zagreb is not a significant source of copper exposure.
Boron exposure assessment using drinking water and urine in the North of Chile.
Cortes, S; Reynaga-Delgado, E; Sancha, A M; Ferreccio, C
2011-12-01
Boron is an essential trace element for plants and humans however it is still an open question what levels of boron are actually safe for humans. This study, conducted between 2006 and 2010, measured exposure levels of boron in drinking water and urine of volunteers in Arica, an area in the North of Chile with high levels of naturally occurring boron. Samples were taken of tap and bottled water (173 and 22, respectively), as well as urine from 22 volunteers, and subsequently analyzed by inductively coupled plasma spectroscopy (ICP-OES). Boron varied in public tap water from 0.22 to 11.3mgL(-1), with a median value of 2.9mgL(-1), while concentrations of boron in bottled water varied from 0.01 to 12.2mgL(-1). Neither tap nor bottled water samples had concentrations of boron within WHO recommended limits. The concentration of boron in urine varied between 0.45 and 17.4mgL(-1), with a median of 4.28mgL(-1) and was found to be correlated with tap water sampled from the homes of the volunteers (r=0.64). Authors highly recommend that in northern Chile - where levels of boron are naturally high - that the tap and bottled water supplies be monitored in order to protect public health and that regulatory standards also be established for boron in drinking water in order to limit exposure. Copyright © 2011 Elsevier B.V. All rights reserved.
Microbial quality of drinking water from microfiltered water dispensers.
Sacchetti, R; De Luca, G; Dormi, A; Guberti, E; Zanetti, F
2014-03-01
A comparison was made between the microbial quality of drinking water obtained from Microfiltered Water Dispensers (MWDs) and that of municipal tap water. A total of 233 water samples were analyzed. Escherichia coli (EC), enterococci (ENT), total coliforms (TC), Staphylococcus aureus, Pseudomonas aeruginosa and heterotrophic plate count (HPC) at 22 °C and 37 °C were enumerated. In addition, information was collected about the principal structural and functional characteristics of each MWD in order to study the various factors that might influence the microbial quality of the water. EC and ENT were not detected in any of the samples. TC were never detected in the tap water but were found in 5 samples taken from 5 different MWDs. S. aureus was found in a single sample of microfiltered water. P. aeruginosa was found more frequently and at higher concentrations in the samples collected from MWDs. The mean HPCs at 22 °C and 37 °C were significantly higher in microfiltered water samples compared to those of the tap water. In conclusion, the use of MWDs may increase the number of bacteria originally present in tap water. It is therefore important to monitor the quality of the dispensed water over time, especially if it is destined for vulnerable users. Copyright © 2013 Elsevier GmbH. All rights reserved.
Quality control of bottled and vended water in California: A review and comparison to tap water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Darby, J.L.; Allen, L.
1994-04-01
Current regulations and compliance for quality control of bottled and vended water in California are compared with that of the tap water industry in this research. Over 35% of the bottled water sold in the US is consumed in California where a third of the residents use such water as a primary source of drinking water. California is one of several states that regulates bottled water more rigorously than the federal government. In California, water quality standards for the two industries are comparable except that many of the organic standards for bottled water are applicable only to the source water,more » a concern due to potential organic contamination during processing. Reporting requirements, significantly less stringent for bottled water, allow considerable latitude in assessing risks and make assessment of compliance difficult. Based on available statistics, compliance for the two industries is comparable; the majority of violations posed no health risks. For both industries, small systems comprised the majority of violations whereas large systems had excellent compliance rates.« less
2013-01-01
Background Few studies have examined water consumption patterns among US children. Additionally, recent data on total water consumption as it relates to the Dietary Reference Intakes (DRI) are lacking. This study evaluated the consumption of plain water (tap and bottled) and other beverages among US children by age group, gender, income-to-poverty ratio, and race/ethnicity. Comparisons were made to DRI values for water consumption from all sources. Methods Data from two non-consecutive 24-hour recalls from 3 cycles of NHANES (2005–2006, 2007–2008 and 2009–2010) were used to assess water and beverage consumption among 4,766 children age 4-13y. Beverages were classified into 9 groups: water (tap and bottled), plain and flavored milk, 100% fruit juice, soda/soft drinks (regular and diet), fruit drinks, sports drinks, coffee, tea, and energy drinks. Total water intakes from plain water, beverages, and food were compared to DRIs for the US. Total water volume per 1,000 kcal was also examined. Results Water and other beverages contributed 70-75% of dietary water, with 25-30% provided by moisture in foods, depending on age. Plain water, tap and bottled, contributed 25-30% of total dietary water. In general, tap water represented 60% of drinking water volume whereas bottled water represented 40%. Non-Hispanic white children consumed the most tap water, whereas Mexican-American children consumed the most bottled water. Plain water consumption (bottled and tap) tended to be associated with higher incomes. No group of US children came close to satisfying the DRIs for water. At least 75% of children 4-8y, 87% of girls 9-13y, and 85% of boys 9-13y did not meet DRIs for total water intake. Water volume per 1,000 kcal, another criterion of adequate hydration, was 0.85-0.95 L/1,000 kcal, short of the desirable levels of 1.0-1.5 L/1,000 kcal. Conclusions Water intakes at below-recommended levels may be a cause for concern. Data on water and beverage intake for the population and by socio-demographic group provides useful information to target interventions for increasing water intake among children. PMID:23782914
Drewnowski, Adam; Rehm, Colin D; Constant, Florence
2013-06-19
Few studies have examined water consumption patterns among U.S. children. Additionally, recent data on total water consumption as it relates to the Dietary Reference Intakes (DRI) are lacking. This study evaluated the consumption of plain water (tap and bottled) and other beverages among US children by age group, gender, income-to-poverty ratio, and race/ethnicity. Comparisons were made to DRI values for water consumption from all sources. Data from two non-consecutive 24-hour recalls from 3 cycles of NHANES (2005-2006, 2007-2008 and 2009-2010) were used to assess water and beverage consumption among 4,766 children age 4-13y. Beverages were classified into 9 groups: water (tap and bottled), plain and flavored milk, 100% fruit juice, soda/soft drinks (regular and diet), fruit drinks, sports drinks, coffee, tea, and energy drinks. Total water intakes from plain water, beverages, and food were compared to DRIs for the U.S. Total water volume per 1,000 kcal was also examined. Water and other beverages contributed 70-75% of dietary water, with 25-30% provided by moisture in foods, depending on age. Plain water, tap and bottled, contributed 25-30% of total dietary water. In general, tap water represented 60% of drinking water volume whereas bottled water represented 40%. Non-Hispanic white children consumed the most tap water, whereas Mexican-American children consumed the most bottled water. Plain water consumption (bottled and tap) tended to be associated with higher incomes. No group of U.S. children came close to satisfying the DRIs for water. At least 75% of children 4-8y, 87% of girls 9-13y, and 85% of boys 9-13y did not meet DRIs for total water intake. Water volume per 1,000 kcal, another criterion of adequate hydration, was 0.85-0.95 L/1,000 kcal, short of the desirable levels of 1.0-1.5 L/1,000 kcal. Water intakes at below-recommended levels may be a cause for concern. Data on water and beverage intake for the population and by socio-demographic group provides useful information to target interventions for increasing water intake among children.
Varol, Simge; Davraz, Aysen
2016-06-01
Isparta city center is selected as a work area in this study because the public believes that the tap water is dirty and harmful. In this study, the city's drinking water in the distribution system and other spring waters which are used as drinking water in this region were investigated from the point of water quality and health risk assessment. Water samples were collected from major drinking water springs, tap waters, treatment plants and dam pond in the Isparta province center. Ca-Mg-HCO3, Mg-Ca-HCO3, Ca-Na-HCO3, Ca-HCO3, Ca-HCO3-SO4 and Ca-Mg-HCO3-SO4 are dominant water types. When compared to drinking water guidelines established by World Health Organization and Turkey, much greater attention should be paid to As, Br, Fe, F, NH4, PO4 through varied chemicals above the critical values. The increases of As, Fe, F, NH4 and PO4 are related to water-rock interaction. In tap waters, the increases of As and Fe are due to corrosion of pipes in drinking water distribution systems. The major toxic and carcinogenic chemicals within drinking water are As and Br for both tap water and spring water. Also, F is the non-carcinogenic chemical for only spring waters in the study area.
Getting the lead out: understanding risks in the distribution ...
This presentation discusses the importance of the water distribution system as a component of the source-to-tap continuum in public health protection. Issues covered include: understanding source water quality changes and their impacts throughout the system; use of mitigation measures such as filters); and holistic approaches and/or strategies that could be used to avoid unintended consequences of decisions from source to tap. Invited presentation on topics indicated as of interest. With exposure to lead as the context, this presentation discusses the importance of the water distribution system as a component of the source-to-tap continuum in public health protection. Issues covered include: understanding source water quality changes and their impacts throughout the system; use of mitigation measures such as filters); and holistic approaches and/or strategies that could be used to avoid unintended consequences of decisions from source to tap.
Kerger, Brent D; Suder, David R; Schmidt, Chuck E; Paustenbach, Dennis J
2005-03-26
This study evaluates airborne concentrations of common trihalomethane compounds (THM) in selected living spaces of homes supplied with chlorinated tap water containing >85 ppb total THM. Three small homes in an arid urban area were selected, each having three bedrooms, a full bath, and approximately 1000 square feet; two homes had standard (refrigeration-type) central air conditioning and the third had a central evaporative cooling system ("swamp cooler"). A high-end water-use pattern was used at each home in this exposure simulation. THM were concurrently measured on 4 separate test days in tap water and air in the bathroom, living room, the bedroom closest to the bathroom, and outside using Summa canisters. Chloroform (trichloromethane, TCM), bromodichloromethane (BDCM), and dibromochloromethane (DBCM) concentrations were quantified using U.S. EPA Method TO-14. The apparent volatilization fraction consistently followed the order: TCM > BDCM > DBCM. Relatively low airborne THM concentrations (similar to outdoors) were found in the living room and bedroom samples for the home with evaporative cooling, while the refrigeration-cooled homes showed significantly higher THM levels (three- to fourfold). This differential remained after normalizing the air concentrations based on estimated THM throughput or water concentrations. These findings indicate that, despite higher throughput of THM-containing water in homes using evaporative coolers, the higher air exchange rates associated with these systems rapidly clears THM to levels similar to ambient outdoor concentrations.
Le Bot, Barbara; Lucas, Jean-Paul; Lacroix, Françoise; Glorennec, Philippe
2016-09-01
29 inorganic compounds (Al, As, B, Ba, Be, Bi, Ca, Cd, Ce, Co, Cr, Cu, Fe, Gd, K, Mg, Mn, Mo, Na, Nd, Ni, Pb, Sb, Se, Sr, Tl, U, V and Zn) were measured in the tap water of 484 representative homes of children aged 6months to 6years in metropolitan France in 2008-2009. Parents were asked whether their children consumed tap water. Sampling design and sampling weights were taken into account to estimate element concentrations in tap water supplied to the 3,581,991 homes of 4,923,058 children aged 6months to 6years. Median and 95th percentiles of concentrations in tap water were in μg/L: Al: <10, 48.3, As: 0.2, 2.1; B: <100, 100; Ba: 30.7, 149.4; Ca: 85,000, 121,700; Cd: <0.5, <0.5; Ce: <0.5, <0.5; Co: <0.5, 0.8; Cr: <5, <5; Cu: 70, 720; K: 2210, 6740; Fe: <20, 46; Mn: <5, <5; Mo: <0.5, 1.5; Na: 14,500, 66,800; Ni: <2, 10.2; Mg: 6500, 21,200; Pb: <1, 5.4; Sb: <0.5, <0.5; Se: <1, 6.7; Sr: 256.9, 1004; Tl: <0.5, <0.5; U: <0.5, 2.4; V: <1, 1; Zn: 53, 208. Of the 2,977,123 young children drinking tap water in France, some were drinking water having concentrations above the 2011 World Health Organization drinking-water quality guidelines: respectively 498 (CI 95%: 0-1484) over 700μg/L of Ba; 121,581 (CI 95%: 7091-236,070) over 50mg/L of Na; 2044 (CI 95%: 0-6132) over 70μg/L of Ni, and 78,466 (17,171-139,761) over 10μg/L of Pb. Since it is representative, this tap water contamination data can be used for integrated exposure assessment, in conjunction with diet and environmental (dust and soil) exposure data. Copyright © 2016 Elsevier Ltd. All rights reserved.
ARSENIC URINARY METABOLITES: BIOMARKER STUDY
A population of adults and children with ranges of 10 to 300 g/l of arsenic in their drinking water will have their urine analyzed for total and speciated arsenic. A sample of 30 families will be selected based on tap water analyses for arsenic. This sample will comprise 50% adul...
Lead (Pb) in tap water (released from Pb-based plumbing materials) poses a serious public health concern. Water utilities experiencing Pb problems often use orthophosphate treatment, with the theory of forming insoluble Pb(II)-orthophosphate compounds on the pipe wall to inhibit ...
Kodamatani, Hitoshi; Yamasaki, Hitomi; Sakaguchi, Takeru; Itoh, Shinya; Iwaya, Yoshimi; Saga, Makoto; Saito, Keiitsu; Kanzaki, Ryo; Tomiyasu, Takashi
2016-08-19
As a contaminant in drinking water, N-nitrosodimethylamine (NDMA) is of great concern because of its carcinogenicity; it has been limited to levels of ng/L by regulatory bodies worldwide. Consequently, a rapid and sensitive method for monitoring NDMA in drinking water is urgently required. In this study, we report an improvement of our previously proposed HPLC-based system for NDMA determination. The approach consists of the HPLC separation of NDMA, followed by NDMA photolysis to form peroxynitrite and detection with a luminol chemiluminescence reaction. The detection limit for the improved HPLC method was 0.2ng/L, which is 10 times more sensitive than our previously reported system. For tap water measurements, only the addition of an ascorbic acid solution to eliminate residual chlorine and passage through an Oasis MAX solid-phase extraction cartridge are needed. The proposed NDMA determination method requires a sample volume of less than 2mL and a complete analysis time of less than 15min per sample. The method was utilized for the long-term monitoring of NDMA in tap water. The NDMA level measured in the municipal water survey was 4.9ng/L, and a seasonal change of the NDMA concentration in tap water was confirmed. The proposed method should constitute a useful NDMA monitoring method for protecting drinking water quality. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Padilla, I. Y.; Cotto, I.; Torres, P. M.
2014-12-01
The karst aquifer region of northern Puerto Rico is the area with the highest groundwater extraction in the island. Urban and industrial development has led to extensive contamination of the groundwater in the region. Of particular concern, is the presence of emerging and legacy organic contaminants, such as phthalates and chlorinated organic compounds (CVOCs), because there high risk for exposure and adverse health impact. Variable sources and the heterogeneous and dynamic conditions of karst groundwater systems, limits the ability to properly assess and manage the water quality of these precious water resources. This work develops a monitoring and water analysis scheme to assess spatial-temporal exposure of hazardous contaminants trough karst water in northern Puerto Rico. Groundwater and tap water are sampled in the region and analyzed for phthalates, CVOCs, and common ions. Detections and concentrations of phthalates and CVOCs are determined by using modified EPA methods, which rely on liquid-liquid extractions and gas chromatography techniques. The modified methods have reduced the volume of samples and solvent waste, decreased the time of analysis, increased analysis outcomes, and lower potential for hazardous exposure. Results show intermittent presence of di-ethyl, di-butyl and di (2-ethyl hexyl) phthalates in 36% of the groundwater and 53% of tap water samples, with detected concentrations ranging between 0.1-88.7 μg/L. These results indicate that karst groundwater can serve as a route of exposure for phthalates, but there are additional disperse sources in the water system. CVOCs are detected in groundwater at much higher frequencies (50%) than phthalates, and include trichloromethane (TCM), carbon tetrachloride (CT), trichloroethylene (TCE), and tetrachloroethylene (TCE). CVOCs, except for TCM, are found at lower frequencies on tap water (5.8%) than groundwater (27%). TCM is detected more frequently and at higher concentrations in tap water (56.8%) than tap water (30%). Results indicated that most CVOCs on tap water come from groundwater sources. Spatial-temporal analysis of CVOC data shows that transport through karst system is highly heterogeneous variable, and reflect high capacity of the system to store and slowly release contaminants through rate-limited mass transport process.
The Canadian Geo-location Endeavour Using Isotopes and Trace Elements in Hair
NASA Astrophysics Data System (ADS)
Chartrand, Michelle M. G.; St-Jean, Gilles; Dalpe, Claude; Wojtyk, James
2010-05-01
The Canadian human hair provenance project has two main objectives: 1) to build a Canadian database of isotopes and trace elements from tap water and hair samples, and 2) to assess the extent of temporal effects on these samples. To address objective 1, a cross-Canada sampling campaign has been started to collect hair and tap water samples. In the past two years, our group has collected samples from the eastern part of Canada (Newfoundland, Nova Scotia, New Brunswick, Prince Edward Island, Quebec and Ontario). Water samples are divided into three groups - groundwater, surface water and bottled water. The GIS maps show the isotopic distribution of the tap water sources varies with latitude. Hair is analyzed for carbon (C), nitrogen (N) and hydrogen (H) isotopes. The C and N results show that in general, Canadians eat a typical diet showing a small isotopic variation. However, some cases will be presented which may explain why some people have C and N values outlying the collected sample average. In terms of H isotopes in human hair, GIS maps illustrate the distribution of this isotope in the eastern provinces of Canada. In some cases, a large variation in H was observed for the same locality with no significant difference in human activities and/or consumption. However, based on hair collected from across Canada from previous years, H isotopes in hair show a correlation to water collected from the same locality. To address objective 2, hair and tap water samples were collected at 4 month intervals (to represent different seasons in Canada) from several volunteers residing in two cities located in the province of Ontario (i.e. Sudbury and Ottawa) and one city from the province of Quebec (i.e. Montreal). For all isotopes measured, there was little variation observed over the course of the year in any individual from those small to medium-size cities. On-going sampling efforts will address if any variation may occur on a yearly basis.
Murphy, H M; Thomas, M K; Medeiros, D T; McFADYEN, S; Pintar, K D M
2016-05-01
The estimated burden of endemic acute gastrointestinal illness (AGI) annually in Canada is 20·5 million cases. Approximately 4 million of these cases are domestically acquired and foodborne, yet the proportion of waterborne cases is unknown. A number of randomized controlled trials have been completed to estimate the influence of tap water from municipal drinking water plants on the burden of AGI. In Canada, 83% of the population (28 521 761 people) consumes tap water from municipal drinking water plants serving >1000 people. The drinking water-related AGI burden associated with the consumption of water from these systems in Canada is unknown. The objective of this research was to estimate the number of AGI cases attributable to consumption of drinking water from large municipal water supplies in Canada, using data from four household drinking water intervention trials. Canadian municipal water treatment systems were ranked into four categories based on source water type and quality, population size served, and treatment capability and barriers. The water treatment plants studied in the four household drinking water intervention trials were also ranked according to the aforementioned criteria, and the Canadian treatment plants were then scored against these criteria to develop four AGI risk groups. The proportion of illnesses attributed to distribution system events vs. source water quality/treatment failures was also estimated, to inform the focus of future intervention efforts. It is estimated that 334 966 cases (90% probability interval 183 006-501 026) of AGI per year are associated with the consumption of tap water from municipal systems that serve >1000 people in Canada. This study provides a framework for estimating the burden of waterborne illness at a national level and identifying existing knowledge gaps for future research and surveillance efforts, in Canada and abroad.
Tap water isotopes reveal the San Francisco Bay Area's plumbing and responses to a major drought
NASA Astrophysics Data System (ADS)
Tipple, B. J.; Jameel, M. Y.; Chau, T. H.; Mancuso, C. J.; Bowen, G. J.; Dufour, A.; Chesson, L. A.; Ehleringer, J. R.
2016-12-01
Water availability and sustainability in the Western United States is a major flashpoint among expanding communities, growing industries, and productive agricultural lands. This issue came to a head in 2015 in the State of California, when the State mandated a 25% reduction in urban water use following a multi-year drought that significantly depleted water resources. The demands for and challenges in supplying water are only expected to intensify as climate perturbations, such as the 2012-2015 California Drought, become more common. As a consequence, there is an increased need to understand linkages between population centers, water transport and usage, and the impacts of climate change on water resources and infrastructure. To better understand these relationships within a megalopolis in the Western United States, we collected and analyzed 723 tap waters from the San Francisco Bay Area during seven collection campaigns across 21 months during 2013-2015. San Francisco Bay Area was selected as it has well-known water management strategies and its water resources were dramatically affected by the 2012-2105 drought. Consistent with known water management strategies and previous reports of tap water isotope values, we found large spatiotemporal variations in the δ2H and δ18O values of tap waters, indicative of complex water transport systems and municipality-scale management decisions. We observed δ2H and δ18O values of tap water consistent with waters originating from snowmelt from the Sierra Nevada Mountains, local precipitation, ground water, and partially evaporated reservoir sources. A cluster analysis of measured tap water data grouped waters from 43 static sampling sites that were associated with specific water utility providers within the San Francisco Bay Area and known management practices. Water management responses to the drought, such as source switching, bringing in new sources, and conservation, could be observed within the isotope data from each of collection campaigns. Finally, we used a modified Craig-Gordon model of evaporative loss from one utility's reservoir system during the 2015 water year to estimate the consequences of the drought on this resource. Using these isotope methods, we estimated that approximately 10% of the water in this reservoir system was lost to evaporation.
Barometric fluctuations in wells tapping deep unconfined aquifers
Weeks, Edwin P.
1979-01-01
Water levels in wells screened only below the water table in unconfined aquifers fluctuate in response to atmospheric pressure changes. These fluctuations occur because the materials composing the unsaturated zone resist air movement and have capacity to store air with a change in pressure. Consequently, the translation of any pressure change at land surface is slowed as it moves through the unsaturated zone to the water table, but it reaches the water surface in the well instantaneously. Thus a pressure imbalance is created that results in a water level fluctuation. Barometric effects on water levels in unconfined aquifers can be computed by solution of the differential equation governing the flow of gas in the unsaturated zone subject to the appropriate boundary conditions. Solutions to this equation for two sets of boundary conditions were applied to compute water level response in a well tapping the Ogallala Formation near Lubbock, Texas from simultaneous microbarograph records. One set of computations, based on the step function unit response solution and convolution, resulted in a very good match between computed and measured water levels. A second set of computations, based on analysis of the amplitude ratios of simultaneous cyclic microbarograph and water level fluctuations, gave inconsistent results in terms of the unsaturated zone pneumatic properties but provided useful insights on the nature of unconfined-aquifer water level fluctuations.
The Danger of Using Tap Water with Contact Lenses
Acanthamoeba is a microbe that is very common in tap water. It has two forms: the trophozoite and the cyst. These trophozoites and cysts can stick to the surface of your contact lenses and then infect your eye.
Schwartz, Thomas; Armant, Olivier; Bretschneider, Nancy; Hahn, Alexander; Kirchen, Silke; Seifert, Martin; Dötsch, Andreas
2015-01-01
The fitness of sensitive and resistant Pseudomonas aeruginosa in different aquatic environments depends on genetic capacities and transcriptional regulation. Therefore, an antibiotic-sensitive isolate PA30 and a multi-resistant isolate PA49 originating from waste waters were compared via whole genome and transcriptome Illumina sequencing after exposure to municipal waste water and tap water. A number of different genomic islands (e.g. PAGIs, PAPIs) were identified in the two environmental isolates beside the highly conserved core genome. Exposure to tap water and waste water exhibited similar transcriptional impacts on several gene clusters (antibiotic and metal resistance, genetic mobile elements, efflux pumps) in both environmental P. aeruginosa isolates. The MexCD-OprJ efflux pump was overexpressed in PA49 in response to waste water. The expression of resistance genes, genetic mobile elements in PA49 was independent from the water matrix. Consistently, the antibiotic sensitive strain PA30 did not show any difference in expression of the intrinsic resistance determinants and genetic mobile elements. Thus, the exposure of both isolates to polluted waste water and oligotrophic tap water resulted in similar expression profiles of mentioned genes. However, changes in environmental milieus resulted in rather unspecific transcriptional responses than selected and stimuli-specific gene regulation. PMID:25186059
Stobbs, L. W.
1990-01-01
In this paper, plans are given for the construction of an inexpensive enzyme-linked immunosorbent assay plate washer from readily available materials. The wash unit uses an intermittent wash cycle based on a wash manifold cycling over the microdilution plates for a predetermined time. Laboratory tests showed that the unit provided reliable, rapid washing of plates with tap water, with no detectable contamination between wells. Substrate absorbance values for test samples from machine-washed plates were equal to or greater than absorbance values for corresponding samples from plates washed manually by an accepted protocol, by using either enzyme-linked immunosorbent assay wash buffer or tap water. Images PMID:16348216
Hydrogeology and quality of ground water in Orange County, Florida
Adamski, James C.; German, Edward R.
2004-01-01
Ground water is the main source of water supply in central Florida and is critical for aquatic habitats and human consumption. To provide a better understanding for the conservation, development, and management of the water resources of Orange County, Florida, a study of the hydrogeologic framework, water budget, and ground-water quality characteristics was conducted from 1998 through 2002. The study also included extensive analyses of the surface-water resources, published as a separate report. An increase in population from about 264,000 in 1960 to 896,000 in 2000 and subsequent urban growth throughout this region has been accompanied by a substantial increase in water use. Total ground-water use in Orange County increased from about 82 million gallons per day in 1965 to about 287 million gallons per day in 2000. The hydrogeology of Orange County consists of three major hydrogeologic units: the surficial aquifer system, the intermediate confining unit, and the Floridan aquifer system. Data were compiled from 634 sites to construct hydrogeologic maps and sections of Orange County. Water-level elevations measured in 23 wells tapping the surficial aquifer system ranged from about 10.6 feet in eastern Orange County to 123.8 feet above NGVD 29 in northwestern Orange County from March 2000 through September 2001. Water levels also were measured in 14 wells tapping the Upper Floridan aquifer. Water levels fluctuate over time from seasonal and annual variations in rainfall; however, water levels in a number of wells tapping the Upper Floridan aquifer have declined over time. Withdrawal of ground water from the aquifers by pumping probably is causing the declines because the average annual precipitation rate has not changed substantially in central Florida since the 1930s, although yearly rates can vary. A generalized water budget was computed for Orange County from 1991 to 2000. Average rates for the 10-year period for the following budget components were computed based on reported measurements or estimates: precipitation was 53 inches per year (in/yr), runoff was 11 in/yr, spring discharge was 2 in/yr, and net lateral subsurface outflow and exported water was 1 in/yr. Evapotranspiration was 39 in/yr, which was calculated as the residual of the water-budget analysis, assuming changes in storage were negligible. Water-quality samples were collected from April 1999 through May 2001 from a total of 26 wells tapping the surficial aquifer system, 1 well tapping the intermediate confining unit, 24 wells tapping the Upper Floridan aquifer, 2 springs issuing from the Upper Floridan aquifer, and 8 wells tapping the Lower Floridan aquifer. These data were supplemented with existing water-quality data collected by the U.S. Geological Survey and St. Johns River Water Management District. Concentrations of total dissolved solids, sulfate, and chloride in samples from the surficial aquifer system generally were low. Concentrations of nitrate were higher in samples from the surficial aquifer system than in samples from the Upper Floridan or Lower Floridan aquifers, probably as a result of agricultural and residential land use. Water type throughout most of the Upper Floridan and Lower Floridan aquifers was calcium or calcium-magnesium bicarbonate, probably as a result of dissolution of the carbonate rocks. Water type in both the surficial and Floridan aquifer systems in eastern Orange County is sodium chloride. Concentrations of total dissolved solids, sulfate, and chloride in the aquifers increase toward eastern Orange County. Data from 16 of 24 wells in eastern Orange County with long-term water-quality records indicated distinct increases in concentrations of chloride over time. The increases probably are related to withdrawal of ground water at the Cocoa well field, causing an upwelling of deeper, more saline water. The most commonly detected trace elements were aluminum, barium, boron, iron, manganese, and strontium. In addition, arse
[Study on chlorinated disinfection byproducts and the relevant health risk in tap water of J City].
Li, Xiao-ling; Liu, Rui; Lan, Ya-qiong; Yu, Su-lin; Wen, Xiao-gang; Chen, Liu-jun; Zhang, Yong-ming
2013-09-01
J City lies in the downstream of Taihu Lake and its water source was micro-polluted by the well-developed industry and agriculture inside the city and in the upper stream. Tap water of J City is characterized as high concentrations of organics and ammonia nitrogen, and chlorinated disinfection byproducts (CDBPs), which has drawn many public concerns for the health risk. Tap water was sampled in May, August, October of 2012 and January of 2013. Four trihalomethanes (THMs) and five haloacetic acids (HAAs) were determined with the gas chromatography. Results revealed that THMs accounted for 88.1% of the sum of THMs and HAAs, with higher concentrations in May, August and January (39.34, 50.37 and 28.02 microg x L(-1), respectively) while obviously lower in October (19.19 microg x L(-1)), which were significantly higher than that of HAAs (2.58-4.02 microg x L(-1)). After boiled for three minutes, THMs were removed over 92.3% but HAAs were largely increased. The health risk of CDBPs was then calculated based on the health risk assessment model recommended by the USEPA. The health risk caused by carcinogenic CDBPs was within a range of 3.1 x 10(-6) - 7. 3 x 10(-6) in the tap water, all over the recommended level of 1 x 10(-6), but after boiled, the value significantly decreased to 7.9 x 10(-7), which is below the recommended level. The health risk caused by non-carcinogenic CDBPs absolutely increased from 2.1 x 10(-11) to 3.4 x 10(-9) after boiled, which is below the reference value of 10(-5).
Zlatanović, Lj; van der Hoek, J P; Vreeburg, J H G
2017-10-15
The drinking water quality changes during the transport through distribution systems. Domestic drinking water systems (DDWSs), which include the plumbing between the water meter and consumer's taps, are the most critical points in which water quality may be affected. In distribution networks, the drinking water temperature and water residence time are regarded as indicators of the drinking water quality. This paper describes an experimental research on the influence of stagnation time and temperature change on drinking water quality in a full-scale DDWS. Two sets of stagnation experiments, during winter and summer months, with various stagnation intervals (up to 168 h of stagnation) were carried out. Water and biofilms were sampled at two different taps, a kitchen and a shower tap. Results from this study indicate that temperature and water stagnation affect both chemical and microbial quality in DDWSs, whereas microbial parameters in stagnant water appear to be driven by the temperature of fresh water. Biofilm formed in the shower pipe contained more total and intact cells than the kitchen pipe biofilm. Alphaproteobacteria were found to dominate in the shower biofilm (78% of all Proteobacteria), while in the kitchen tap biofilm Alphaproteobacteria, Betaproteobacteria and Gammaproteobacteria were evenly distributed. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Drinking water: a risk factor for high incidence of esophageal cancer in Anyang, China.
Cao, Wenbo; Han, Jianying; Yuan, Yi; Xu, Zhixiang; Yang, Shengli; He, Weixin
2016-06-01
Anyang is known to be a high-incidence area of esophageal cancer (EC) in China. Among a long list of risk factors, the quality of drinking water was evaluated. We have selected 3806 individuals and collected 550 drinking water samples correspondent with this not-matched case-control survey. There are 531 EC patients included based on Population Cancer Registry from 92 townships, of which 3275 controls with long-lived aged over 90 years and free from EC are used as controls in the same regions. Our result suggests that the quality of drinking water is a highly associated risk factor for EC. The residential ecological environment and the quality of water resource positively link with each other. The analysis of water samples also demonstrated that the concentrations of methyl ethylamine, morpholine, N-methylbenzylamine, nitrate and chloride in water from springs and rivers are higher than those in well and tap water (P = 0.001). Micronuclei formation tests show that well water and tap water in these regions have no mutagenicity.
Balada-Llasat, Joan-Miquel; Elkins, Camille; Swyers, Lettie; Bannerman, Tammy; Pancholi, Preeti
2010-07-01
Cupriavidus pauculus is a water microorganism rarely isolated from clinical specimens. We describe a pseudo-outbreak in which multiple strains that were associated with moistening of culturette swabs with tap water were isolated from a single clinic before collecting the patient specimen.
Towards metering tap water by Lorentz force velocimetry
NASA Astrophysics Data System (ADS)
Vasilyan, Suren; Ebert, Reschad; Weidner, Markus; Rivero, Michel; Halbedel, Bernd; Resagk, Christian; Fröhlich, Thomas
2015-11-01
In this paper, we present enhanced flow rate measurement by applying the contactless Lorentz Force Velocimetry (LFV) technique. Particularly, we show that the LFV is a feasible technique for metering the flow rate of salt water in a rectangular channel. The measurements of the Lorentz forces as a function of the flow rate are presented for different electrical conductivities of the salt water. The smallest value of conductivity is achieved at 0.06 S·m-1, which corresponds to the typical value of tap water. In comparison with previous results, the performance of LFV is improved by approximately 2 orders of magnitude by means of a high-precision differential force measurement setup. Furthermore, the sensitivity curve and the calibration factor of the flowmeter are provided based on extensive measurements for the flow velocities ranging from 0.2 to 2.5 m·s-1 and conductivities ranging from 0.06 to 10 S·m-1.
Evaluation of exposure to lead from drinking water in large buildings.
Deshommes, Elise; Andrews, Robert C; Gagnon, Graham; McCluskey, Tim; McIlwain, Brad; Doré, Evelyne; Nour, Shokoufeh; Prévost, Michèle
2016-08-01
Lead results from 78,971 water samples collected in four Canadian provinces from elementary schools, daycares, and other large buildings using regulatory and investigative sampling protocols were analyzed to provide lead concentration distributions. Maximum concentrations reached 13,200 and 3890 μg/L following long and short stagnation periods respectively. High lead levels were persistent in some large buildings, reflected by high median values considering all taps, or specific to a few taps in the building. Simulations using the Integrated Uptake Biokinetic (IEUBK) model and lead concentrations after 30 min of stagnation in the dataset showed that, for most buildings, exposure to lead at the tap does not increase children's blood lead levels (BLLs). However, buildings or taps with extreme concentrations represent a significant health risk to young children attending school or daycare, as the estimated BLL far exceeded the 5 μg/dL threshold. Ingestion of water from specific taps could lead to acute exposure. Finally, for a few taps, the total daily lead intake reached the former World Health Organization (WHO) tolerable level for adults, suggesting potential health risks. Copyright © 2016 Elsevier Ltd. All rights reserved.
Santhi, V A; Sakai, N; Ahmad, E D; Mustafa, A M
2012-06-15
This study investigated the level of bisphenol A (BPA) in surface water used as potable water, drinking water (tap and bottled mineral water) and human plasma in the Langat River basin, Malaysia. BPA was present in 93% of the surface water samples at levels ranging from below limit of quantification (LOQ; 1.3 ng/L) to 215 ng/L while six fold higher levels were detected in samples collected near industrial and municipal sewage treatment plant outlets. Low levels of BPA were detected in most of the drinking water samples. BPA in tap water ranged from 3.5 to 59.8 ng/L with the highest levels detected in samples collected from taps connected to PVC pipes and water filter devices. Bottled mineral water had lower levels of BPA (3.3±2.6 ng/L) although samples stored in poor storage condition had significantly higher levels (11.3±5.3 ng/L). Meanwhile, only 17% of the plasma samples had detectable levels of BPA ranging from 0.81 to 3.65 ng/mL. The study shows that BPA is a ubiquitous contaminant in surface, tap and bottled mineral water. However, exposure to BPA from drinking water is very low and is less than 0.01% of the tolerable daily intake (TDI). Copyright © 2012 Elsevier B.V. All rights reserved.
Assessment of potable water quality including organic, inorganic, and trace metal concentrations.
Nahar, Mst Shamsun; Zhang, Jing
2012-02-01
The quality of drinking water (tap, ground, and spring) in Toyama Prefecture, Japan was assessed by studying quality indicators including major ions, total carbon, and trace metal levels. The physicochemical properties of the water tested were different depending on the water source. Major ion concentrations (Ca(2+), K(+), Si(4+), Mg(2+), Na(+), SO(4)(2-), HCO(3)(-), NO(3)(-), and Cl(-)) were determined by ion chromatography, and the results were used to generate Stiff diagrams in order to visually identify different water masses. Major ion concentrations were higher in ground water than in spring and tap water. The relationship between alkaline metals (Na(+) and K(+)), alkaline-earth metals (Ca(2+) and Mg(2+)), and HCO(3)(-) showed little difference between deep and shallow ground water. Toyama ground, spring, and tap water were all the same type of water mass, called Ca-HCO(3). The calculated total dissolved solid values were below 300 mg/L for all water sources and met World Health Organization (WHO) water quality guidelines. Trace levels of As, Cd, Cr, Co, Cu, Fe, Pb, Mn, Mo, Ni, V, Zn, Sr, and Hg were detected in ground, spring, and tap water sources using inductively coupled plasma atomic emission spectrometry, and their levels were below WHO and Japanese water quality standard limits. Volatile organic carbon compounds were quantified by headspace gas chromatography-mass spectrometry, and the measured concentrations met WHO and Japanese water quality guidelines. Total trihalomethanes (THMs) were the major contaminant detected in all natural drinking water sources, but the concentration was highest in tap water (37.27 ± 0.05 μg/L). Notably, THMs concentrations reached up to 1.1 ± 0.05 μg/L in deep ground water. The proposed model gives an accurate description of the organic, inorganic, and trace heavy metal indicators studied here and may be used in natural clean water quality management. © Springer Science+Business Media B.V. 2011
Thompson, Chad M; Gaylor, David W; Tachovsky, J Andrew; Perry, Camarie; Carakostas, Michael C; Haws, Laurie C
2013-12-01
Sulfolane is a widely used industrial solvent that is often used for gas treatment (sour gas sweetening; hydrogen sulfide removal from shale and coal processes, etc.), and in the manufacture of polymers and electronics, and may be found in pharmaceuticals as a residual solvent used in the manufacturing processes. Sulfolane is considered a high production volume chemical with worldwide production around 18 000-36 000 tons per year. Given that sulfolane has been detected as a contaminant in groundwater, an important potential route of exposure is tap water ingestion. Because there are currently no federal drinking water standards for sulfolane in the USA, we developed a noncancer oral reference dose (RfD) based on benchmark dose modeling, as well as a tap water screening value that is protective of ingestion. Review of the available literature suggests that sulfolane is not likely to be mutagenic, clastogenic or carcinogenic, or pose reproductive or developmental health risks except perhaps at very high exposure concentrations. RfD values derived using benchmark dose modeling were 0.01-0.04 mg kg(-1) per day, although modeling of developmental endpoints resulted in higher values, approximately 0.4 mg kg(-1) per day. The lowest, most conservative, RfD of 0.01 mg kg(-1) per day was based on reduced white blood cell counts in female rats. This RfD was used to develop a tap water screening level that is protective of ingestion, viz. 365 µg l(-1). It is anticipated that these values, along with the hazard identification and dose-response modeling described herein, should be informative for risk assessors and regulators interested in setting health-protective drinking water guideline values for sulfolane. Copyright © 2012 John Wiley & Sons, Ltd.
The relation of communication to risk judgment and preventive behavior related to lead in tap water.
Griffin, R J; Dunwoody, S
2000-01-01
More and more communities are becoming concerned about health risks posed by lead and other health hazards in their drinking water. Our study, applying the model of innovation diffusion to the adoption of preventive health behaviors, found that reliance on health professionals for information about lead in tap water was associated with residents perceiving risk from this hazard, their sense of efficacy in dealing with it, and their adoption of preventive behaviors. Mass media and pamphlets mailed directly to residents were relatively ineffective. Results suggest that interpersonal channels may be the best way to reach individuals who live in areas of highest risk from tap water lead.
2013-01-01
Background Few studies have examined plain water consumption among US adults. This study evaluated the consumption of plain water (tap and bottled) and total water among US adults by age group (20-50y, 51-70y, and ≥71y), gender, income-to-poverty ratio, and race/ethnicity. Methods Data from up to two non-consecutive 24-hour recalls from the 2005–2006, 2007–2008 and 2009–2010 National Health and Nutrition Examination Survey (NHANES) was used to evaluate usual intake of water and water as a beverage among 15,702 US adults. The contribution of different beverage types (e.g., water as a beverage [tap or bottled], milk [including flavored], 100% fruit juice, soda/soft drinks [regular and diet], fruit drinks, sports/energy drinks, coffee, tea, and alcoholic beverages) to total water and energy intakes was examined. Total water intakes from plain water, beverages, and food were compared to the Adequate Intake (AI) values from the US Dietary Reference Intakes (DRI). Total water volume per 1,000 kcal was also examined. Results Water and other beverages contributed 75-84% of dietary water, with 17-25% provided by water in foods, depending on age. Plain water, from tap or bottled sources, contributed 30-37% of total dietary water. Overall, 56% of drinking water volume was from tap water while bottled water provided 44%. Older adults (≥71y) consumed much less bottled water than younger adults. Non-Hispanic whites consumed the most tap water, whereas Mexican-Americans consumed the most bottled water. Plain water consumption (bottled and tap) tended to be associated with higher incomes. On average, younger adults exceeded or came close to satisfying the DRIs for water. Older men and women failed to meet the Institute of Medicine (IOM) AI values, with a shortfall in daily water intakes of 1218 mL and 603 mL respectively. Eighty-three percent of women and 95% of men ≥71y failed to meet the IOM AI values for water. However, average water volume per 1,000 kcal was 1.2-1.4 L/1,000 kcal for most population sub-groups, higher than suggested levels of 1.0 L/1.000 kcal. Conclusions Water intakes below IOM-recommended levels may be a cause for concern, especially for older adults. PMID:24219567
Desalinated drinking water in the GCC countries - The need to address consumer perceptions.
Shomar, Basem; Hawari, Jalal
2017-10-01
The Gulf Cooperation Council (GCC) countries consist of Bahrain, Kuwait, Oman, Qatar, Saudi Arabia, and the United Arab Emirates. These countries depend mainly on seawater desalination to meet their water needs. Although great emphasis is given to characterize desalinated water for its physicochemical and microbial properties, e.g. presence of metals, other organic contaminants and for bacteria, sensorial characteristics including smell, taste and color have not received the same attention. This is possibly attributed to the fact that inhabitants of GCC States do not use desalinated tap water for drinking consumption, rather they depend on locally produced or imported bottled water where color, taste and odor are not problematic. To address the consumer needs and perceptions of drinking desalinated water in GCC countries, water quality standards and guidelines, should respond to the public concern about other sensorial characteristics (organoleptic properties) including taste, odor, and trigeminal sensations. Often the root causes of color and smell in water are attributed to the presence of organic and inorganic contaminants and to bacterial growth which is frequently accompanied by the production of metabolites and byproducts that are obnoxious. The unpleasant sensorial problems associated with desalinated drinking tap water may constitute the driving force for most people in GCC countries to depend on bottled water. To encourage people in the GCC countries to consume desalinated tap water, it is essential that water testing include measurements of physicochemical properties, biofilm presence and organoleptic parameters to improve overall water quality. This review highlights the contribution of organoleptics for consumers of desalinated tap water. It extends water quality research to be addressed by standards for organoleptic parameters in desalinated drinking water. Accordingly, consumer awareness and outreach campaigns should be implemented to encourage people to drink tap water in the GCC countries. Copyright © 2017 Elsevier Inc. All rights reserved.
Survey of human pharmaceuticals in drinking water in the Czech Republic.
Kozisek, Frantisek; Pomykacova, Ivana; Jeligova, Hana; Cadek, Vaclav; Svobodova, Veronika
2013-03-01
The first large-scale assessment of pharmaceuticals in drinking water in the Czech Republic (CR) focused on the detection of five substances. Samples were collected from public water systems supplying 5.3 million people, 50.5% of the Czech population. In the initial survey of tap water from 92 major supply zones using mostly surface water, no pharmaceutical exceeded the limit of quantification (LOQ = 0.5 ng/L). In a second survey, samples were collected from the outlet of 23 water treatment plants (WTPs) considered of high risk because they use surface waters influenced by wastewater. Ibuprofen was the most frequently found pharmaceutical (19 samples), followed by carbamazepine (12), naproxen (8), and diclofenac (3); concentrations ranged from 0.5 to 20.7 ng/L, with medians below 6 ng/L. Concentrations of 17α-ethinylestradiol were below the LOQ. A follow-up survey included tap and outlet samples from eight of the 23 WTPs with the highest concentrations. Pharmaceuticals were quantified in only three tap water samples. Regarding risks to consumers, these results suggest that a relatively small population (<10%) in the CR is exposed to quantifiable concentrations of pharmaceuticals in tap water and that an extremely high margin of safety (several thousand-fold to several million-fold) is associated with these exposures.
40 CFR 141.86 - Monitoring requirements for lead and copper in tap water.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Monitoring requirements for lead and... § 141.86 Monitoring requirements for lead and copper in tap water. (a) Sample site location. (1) By the applicable date for commencement of monitoring under paragraph (d)(1) of this section, each water system...
40 CFR 141.86 - Monitoring requirements for lead and copper in tap water.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 24 2013-07-01 2013-07-01 false Monitoring requirements for lead and... § 141.86 Monitoring requirements for lead and copper in tap water. (a) Sample site location. (1) By the applicable date for commencement of monitoring under paragraph (d)(1) of this section, each water system...
40 CFR 141.86 - Monitoring requirements for lead and copper in tap water.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 24 2012-07-01 2012-07-01 false Monitoring requirements for lead and... § 141.86 Monitoring requirements for lead and copper in tap water. (a) Sample site location. (1) By the applicable date for commencement of monitoring under paragraph (d)(1) of this section, each water system...
A Lab Experience to Illustrate the Physicochemical Principles of Detergency
ERIC Educational Resources Information Center
Poce-Fatou, J. A.; Bethencourt-Nunez, M.; Moreno, C.; Pinto-Ganfornina, J. J.; Moreno-Dorado, F. J.
2008-01-01
This article presents a lab experience to study detergency from a physicochemical point of view intended for undergraduate students. By means of a simple experimental device, we analyze the influence of the surfactant concentration in both distilled water and tap water. Our method is based on the measurement of diffuse reflectances of polyester…
Chemical quality of tap water in Madrid: multicase control cancer study in Spain (MCC-Spain).
Fernández-Navarro, Pablo; Villanueva, Cristina M; García-Pérez, Javier; Boldo, Elena; Goñi-Irigoyen, Fernando; Ulibarrena, Enrique; Rantakokko, Panu; García-Esquinas, Esther; Pérez-Gómez, Beatriz; Pollán, Marina; Aragonés, Nuria
2017-02-01
Chronic consumption of water, which contains contaminants, may give rise to adverse health effects. The Madrid region, covered by the population-based multicase-control (MCC-Spain) study, includes two drinking water supply areas. The different sources of the water, coupled together with the possible differences in water management, mean that there may be differences in drinking water quality. In the context of the MCC study, our aims were to describe contaminant concentrations in tap water drawn from various sampling points distributed around the region, assess these concentrations by reference to guideline values and study possible differences between the two supply areas. Tap water samples were collected from 34 sampling points in 7 towns in the Madrid region (19-29 April 2010), and 23 contaminants (metals, nitrates, disinfection by-product and Mutagen X levels) were quantified. We undertook a descriptive analysis of the contaminant concentrations in the water and compared them between the two water supply areas (Wilcoxon test). We created maps representing the distribution of the concentrations observed at water sampling points and assessed the correlations (Spearman's coefficient) between the different parameters measured. The concentrations of the contaminants were below guideline values. There were differences between the two supply areas in concentration of nitrates (p value = 0.0051) and certain disinfection by-products. While there were positive correlations (rho >0.70) among some disinfection by-products, no correlations were found in metals or nitrates. The differences in nitrate levels could be linked to differences in farming/industrial activities in the catchment areas and in disinfection by-products might be related to the existence of different treatment systems or bromine content in source waters.
On-tap passive enrichment, a new way to investigate off-flavor episodes in drinking water.
Tondelier, Christophe; Thouvenot, Thomas; Genin, Arnaud; Benanou, David
2009-04-03
Because taste and odor events in drinking water are often fleeting and unpredictable phenomena, an innovative enrichment sampler has been developed to trap off-flavor compounds directly at the consumer's tap. The ARISTOT (Advanced Relevant Investigation Sampler for Taste & Odor at Tap) consists of a tap adapter in which seven polydimethylsiloxane (PDMS) coated stir bars are placed, allowing the stir bar sorptive extraction (SBSE) of organic compounds during each tap opening. In order to study the efficiency of ARISTOT, a private network pilot unit has been constructed in our laboratory, equipped with four faucets in parallel, solenoid valves for an automation of the system and a mixing chamber to spike drinking water with odorous compounds in order to have homogenously smelling water at each tap. After enrichment, the stir bars are taken out, in-line thermo-desorbed and analyzed by gas chromatography coupled with a mass spectrometer. The results showed the high sensitivity of ARISTOT, which was able to quickly monitor odorous compounds at the sub ng/L level. A "multishot" method was developed to analyze chemicals concentrated on the seven stir bars in only one chromatographic run, thereby increasing the sensitivity of the system. Higher enrichment factors were obtained under low water flow rates or by using longer stir bars and/or stir bars with a higher PDMS film thickness. No significant loss of extracted compounds was reported for flow rates between 2 and 4L/min. This allowed us to spike the stir bars with an internal standard prior to sampling in order to monitor the analytical variations. It was also observed that hot water increases the loss of enriched solutes but the quantification can be corrected by internal standard addition.
Ahmed, Farid; Perveen, Samina; Shah, Kiramat; Shah, Muhammad Raza; Ahmed, Shakil
2018-01-01
In this study a new calix[4]arene triazole 5 was successfully synthesized using click reaction and characterized through UV-visible, FT-IR, 1 H NMR spectroscopes and Mass Spectrometry. The supramolecular interaction of compound 5 towards commonly used drugs has been carried out using UV-Visible spectroscopy. The supramolecule 5 showed characteristic enhancement in the absorbance intensity after mixing with Cefuroxime at pH (2-12). Compound 5 displayed considerably good interactions with cefuroxime in the presence of other drugs. Compound 5 exhibits linear relationship with cefuroxime concentration in the range of (10-80µM) with regression value of 0.9954. The standard deviation for 50µM Cefuroxime was found to be 0.01 and the limit of detection for cefuroxime was calculated to be 2µM. Job's plot experiments showed 1:1 (5: cefuroxime) binding stoichiometry between compound 5 and cefuroxime. Supramolecule 5 displayed fairly good spectrophotometric recognition of Cefuroxime in human blood plasma and tap water thus showing that the ingredients of tap water and plasma sample was inert in the recognition of cefuroxime. Copyright © 2017 Elsevier Inc. All rights reserved.
A Contactless Capacitance Detection System for Microchip Capillary Electrophoresis
NASA Astrophysics Data System (ADS)
Wu, Peter
2008-05-01
The design, construction and operation of a simple, inexpensive and compact high voltage power supply for use in conjunction with a simple cross, capillary electrophoresis microchip is presented. The detection system utilizes a single high voltage power supply (15 kV), a voltage divider network for obtaining the required voltages for enabling a gated injection valve, and two high voltage relays for switching between the open and closed gate sequences of the injection. The system is used to determine sodium monofluoroacetate (MFA) concentration in diluted fruit juices and tap water. A separation buffer consisting of 20 mM citric acid and histidine at pH 3.5 enabled the detection of the anion in diluted apple juice, cranberry juice, and orange juice without lengthy sample pretreatments. Limit of detection in diluted juices and tap water were determined to be 125, 167, 138, and 173 mg/L for tap water, apple juice, cranberry juice, and orange juice, respectively, based upon an S/N of 3:1. The total analysis time for detecting the MFA anion in fruit juices was less than 5 min, which represents a considerable reduction in analysis time compared to other analytical methods currently used in food analysis.
Contribution of tap water to chlorate and perchlorate intake: a market basket study.
Asami, Mari; Yoshida, Nobue; Kosaka, Koji; Ohno, Koichi; Matsui, Yoshihiko
2013-10-01
The contributions of water to total levels of chlorate and perchlorate intake were determined using food and water samples from a market basket study from 10 locations in Japan between 2008 and 2009. Foods were categorized into 13 groups and analyzed along with tap water. The average total chlorate intake was 333 (min. 193-max. 486) μg/day for samples cooked with tap water. The contribution of tap water to total chlorate intake was as high as 47%-58%, although total chlorate intake was less than 32% of the tolerable daily intake, 1500 μg/day for body weight of 50 kg. For perchlorate, daily intake from water was 0.7 (0.1-4.4) μg/day, which is not high compared to the average total intake of 14 (2.5-84) μg/day, while the reference dose (RfD) is 35 μg/day and the provisional maximum tolerable daily intake (PMTDI) is 500 μg/day for body weight of 50 kg. The highest intake of perchlorate was 84 μg/day, where concentrations in foods were high, but not in water. The contribution of water to total perchlorate intake ranged from 0.5% to 22%, while the ratio of highest daily intake to RfD was 240% and that to PMTDI was 17%. Eight baby formulas were also tested--total chlorate and perchlorate intakes were 147 (42-332) μg/day and 1.11 (0.05-4.5) μg/day, respectively, for an ingestion volume of 1 L/day if prepared with tap water. Copyright © 2013 The Authors. Published by Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Gooding, J. L.; Ming, D. W.; Gruener, J. E.; Gibbons, F. L.; Allton, J. H.
1993-01-01
Thermal Analyzer for Planetary Soil (TAPS) offers a specific implementation for the generic thermal analyzer/evolved-gas analyzer (TA/EGA) function included in the Mars Environmental Survey (MESUR) strawman payload; applications to asteroids and comets are also possible. The baseline TAPS is a single-sample differential scanning calorimeter (DSC), backed by a capacitive-polymer humidity sensor, with an integrated sampling mechanism. After placement on a planetary surface, TAPS acquires 10-50 mg of soil or sediment and heats the sample from ambient temperature to 1000-1300 K. During heating, DSC data are taken for the solid and evolved gases are swept past the water sensor. Through ground based data analysis, multicomponent DSC data are deconvolved and correlated with the water release profile to quantitatively determine the types and relative proportions of volatile-bearing minerals such as clays and other hydrates, carbonates, and nitrates. The rapid-response humidity sensors also achieve quantitative analysis of total water. After conclusion of soil-analysis operations, the humidity sensors become available for meteorology. The baseline design fits within a circular-cylindrical volume less than 1000 cm(sup 3), occupies 1.2 kg mass, and consumes about 2 Whr of power per analysis. Enhanced designs would acquire and analyze multiple samples and employ additional microchemical sensors for analysis of CO2, SO2, NO(x), and other gaseous species. Atmospheric pumps are also being considered as alternatives to pressurized purge gas.
NASA Astrophysics Data System (ADS)
Gooding, J. L.; Ming, D. W.; Gruener, J. E.; Gibbons, F. L.; Allton, J. H.
Thermal Analyzer for Planetary Soil (TAPS) offers a specific implementation for the generic thermal analyzer/evolved-gas analyzer (TA/EGA) function included in the Mars Environmental Survey (MESUR) strawman payload; applications to asteroids and comets are also possible. The baseline TAPS is a single-sample differential scanning calorimeter (DSC), backed by a capacitive-polymer humidity sensor, with an integrated sampling mechanism. After placement on a planetary surface, TAPS acquires 10-50 mg of soil or sediment and heats the sample from ambient temperature to 1000-1300 K. During heating, DSC data are taken for the solid and evolved gases are swept past the water sensor. Through ground based data analysis, multicomponent DSC data are deconvolved and correlated with the water release profile to quantitatively determine the types and relative proportions of volatile-bearing minerals such as clays and other hydrates, carbonates, and nitrates. The rapid-response humidity sensors also achieve quantitative analysis of total water. After conclusion of soil-analysis operations, the humidity sensors become available for meteorology. The baseline design fits within a circular-cylindrical volume less than 1000 cm3, occupies 1.2 kg mass, and consumes about 2 Whr of power per analysis. Enhanced designs would acquire and analyze multiple samples and employ additional microchemical sensors for analysis of CO2, SO2, NO(x), and other gaseous species. Atmospheric pumps are also being considered as alternatives to pressurized purge gas.
Use of an Electronic Tongue System and Fuzzy Logic to Analyze Water Samples
NASA Astrophysics Data System (ADS)
Braga, Guilherme S.; Paterno, Leonardo G.; Fonseca, Fernando J.
2009-05-01
An electronic tongue (ET) system incorporating 8 chemical sensors was used in combination with two pattern recognition tools, namely principal component analysis (PCA) and Fuzzy logic for discriminating/classification of water samples from different sources (tap, distilled and three brands of mineral water). The Fuzzy program exhibited a higher accuracy than the PCA and allowed the ET to classify correctly 4 in 5 types of water. Exception was made for one brand of mineral water which was sometimes misclassified as tap water. On the other hand, the PCA grouped water samples in three clusters, one with the distilled water; a second with tap water and one brand of mineral water, and the third with the other two other brands of mineral water. Samples in the second and third clusters could not be distinguished. Nevertheless, close grouping between repeated tests indicated that the ET system response is reproducible. The potential use of the Fuzzy logic as the data processing tool in combination with an electronic tongue system is discussed.
Perceptions on the use of bottled water in restaurants in Harare's Central Business District (CBD)
NASA Astrophysics Data System (ADS)
Juba, Olivia Sakhile; Tanyanyiwa, Vincent Itai
2018-06-01
Bottled water use continues to expand worldwide and in the last two decades, a significant number of consumers have shifted from tap water to bottled water due to Cryptosporidium outbreaks. Bottled water consumption has increased in Harare due to erratic tap water supplies. Since 2011, forty bottled water brands have been banned because of failure to meet safety and quality standards due to contamination, unsuitable packaging, and wrong labelling. Nevertheless, the bottled water industry continues to thrive as local authorities fail to adequately purify municipal water. The study assessed the perceptions on drinking bottled water in restaurants within Harare's CBD. Demographic and social factors associated with bottled water users were established and the role and influence of stakeholders in bottling and distribution of water documented. A field survey through the administration of questionnaires to fifty restaurant users was carried out to assess the perceptions of people on the use of bottled water in terms of its safety and potential health benefits. Key informant interviews were conducted using a semi-structured interview with ten local water bottling companies as well as representatives from the Environmental Management Agency (EMA) and Standards Association of Zimbabwe (SAZ). Data were analysed using descriptive statistics and logistic regression analysis. Standard descriptive statistics were generated, with 95% confidence intervals (95% CIs). Consumers used bottled water as their primary drinking water source when they perceived that tap water was not safe. Perceptions of purity of water, bottled water convenience, and tap water unavailability seemed to determine consumption patterns among users. Females in the 18-48 age groups were more likely to think that bottled water was cleaner, safer, tasted better and was more convenient than tap water. Consumers regularly purchased bottled water for drinking and used bottled water as their primary drinking water source regardless of cost implications. Government and local authorities need to ensure that pure and clean water is availed in Harare. In addition, the public must be engaged in recognizing the relationships that exist between water quality and the capacity of local authorities to maintain taste and safety standards.
APPLICATION OF EPANET TO UNDERSTAND LEAD ...
This presentation describes the factors affecting lead concentration in tap water using an EPANET hydraulic model for a simplified home model, a realistic home model, and EPA's experimental home plumbing system. This presentation describes the factors affecting lead concentration in tap water using an EPANET hydraulic model.
Siah, Tee Wei; Hampton, Philip J
2013-03-15
Primary focal hyperhidrosis is a benign condition of unknown etiology. Tap water iontophoresis has long been known to inhibit sweat production. The mechanism of reduced hyperhidrosis by iontophoresis is not completely clear. For operational convenience, our patients received their treatments at different intervals to those recommended by the manufacturer of the iontophoresis unit. We performed a retrospective audit to evaluate the effectiveness of tap water iontophoresis using this regimen. This new treatment regimen was effective at controlling palmoplantar hyperhidrosis. Minimal undesirable effects such as mild skin irritation and erythema were noted but none were severe enough to necessitate discontinuation of treatment. In conclusion, tap water iontophoresis is a safe and effective treatment of palmar and plantar hyperhidrosis when used on Monday, Wednesday, and Friday for 4 weeks. Continued treatment is needed to maintain the effect and many patients go on to purchase their own machines. This technique should be considered prior to systemic or aggressive surgical intervention.
Schwartz, Thomas; Armant, Olivier; Bretschneider, Nancy; Hahn, Alexander; Kirchen, Silke; Seifert, Martin; Dötsch, Andreas
2015-01-01
The fitness of sensitive and resistant Pseudomonas aeruginosa in different aquatic environments depends on genetic capacities and transcriptional regulation. Therefore, an antibiotic-sensitive isolate PA30 and a multi-resistant isolate PA49 originating from waste waters were compared via whole genome and transcriptome Illumina sequencing after exposure to municipal waste water and tap water. A number of different genomic islands (e.g. PAGIs, PAPIs) were identified in the two environmental isolates beside the highly conserved core genome. Exposure to tap water and waste water exhibited similar transcriptional impacts on several gene clusters (antibiotic and metal resistance, genetic mobile elements, efflux pumps) in both environmental P. aeruginosa isolates. The MexCD-OprJ efflux pump was overexpressed in PA49 in response to waste water. The expression of resistance genes, genetic mobile elements in PA49 was independent from the water matrix. Consistently, the antibiotic sensitive strain PA30 did not show any difference in expression of the intrinsic resistance determinants and genetic mobile elements. Thus, the exposure of both isolates to polluted waste water and oligotrophic tap water resulted in similar expression profiles of mentioned genes. However, changes in environmental milieus resulted in rather unspecific transcriptional responses than selected and stimuli-specific gene regulation. © 2014 The Authors. Microbial Biotechnology published by John Wiley & Sons Ltd and Society for Applied Microbiology.
The real water consumption behind drinking water: the case of Italy.
Niccolucci, V; Botto, S; Rugani, B; Nicolardi, V; Bastianoni, S; Gaggi, C
2011-10-01
The real amount of drinking water available per capita is a topic of great interest for human health and the economic and political management of resources. The global market of bottled drinking water, for instance, has shown exponential growth in the last twenty years, mainly due to reductions in production costs and investment in promotion. This paper aims to evaluate how much freshwater is actually consumed when water is drunk in Italy, which can be considered a mature bottled-water market. A Water Footprint (WF) calculation was used to compare the alternatives: bottled and tap water. Six Italian brands of water sold in PET bottles were inventoried, analysed and compared with the public tap water of the city of Siena, as representative of the Italian context. Results showed that more than 3 L of water were needed to provide consumers with 1.50 L of drinking water. In particular, a volume of 1.50 L of PET-bottled water required an extra virtual volume of 1.93 L of water while an extra 2.13 L was necessary to supply the same volume of tap water. These values had very different composition and origin. The WF of tap water was mainly due to losses of water during pipeline distribution and usage, while WF of bottled water was greatly influenced by the production of plastic materials. When the contribution of cooling water was added to the calculation, the WF of bottled water rose from 3.43 to 6.92 L. Different strategies to reduce total water footprint are discussed. Copyright © 2011 Elsevier Ltd. All rights reserved.
Yang, Xinchao; Wang, Ke; Wang, Huijun; Zhang, Jianhua; Mao, Zhonggui
2016-11-01
An process of integrated ethanol-methane fermentation with improved economics has been studied extensively in recent years, where the process water used for a subsequent fermentation of carbohydrate biomass is recycled. This paper presents a systematic study of the ethanol fermentation characteristics of recycled process water. Compared with tap water, fermentation time was shortened by 40% when mixed water was employed. However, while the maximal ethanol production rate increased from 1.07g/L/h to 2.01g/L/h, ethanol production was not enhanced. Cell number rose from 0.6×10(8) per mL in tap water to 1.6×10(8) per mL in mixed water but although biomass increased, cell morphology was not affected. Furthermore, the use of mixed water increased the glycerol yield but decreased that of acetic acid, and the final pH with mixed water was higher than when using tap water. Copyright © 2016 Elsevier Ltd. All rights reserved.
Nuckols, John R; Ashley, David L; Lyu, Christopher; Gordon, Sydney M; Hinckley, Alison F; Singer, Philip
2005-07-01
Individual exposure to trihalomethanes (THMs) in tap water can occur through ingestion, inhalation, or dermal exposure. Studies indicate that activities associated with inhaled or dermal exposure routes result in a greater increase in blood THM concentration than does ingestion. We measured blood and exhaled air concentrations of THM as biomarkers of exposure to participants conducting 14 common household water use activities, including ingestion of hot and cold tap water beverages, showering, clothes washing, hand washing, bathing, dish washing, and indirect shower exposure. We conducted our study at a single residence in each of two water utility service areas, one with relatively high and the other low total THM in the residence tap water. To maintain a consistent exposure environment for seven participants, we controlled water use activities, exposure time, air exchange, water flow and temperature, and nonstudy THM sources to the indoor air. We collected reference samples for water supply and air (pre-water use activity), as well as tap water and ambient air samples. We collected blood samples before and after each activity and exhaled breath samples at baseline and post-activity. All hot water use activities yielded a 2-fold increase in blood or breath THM concentrations for at least one individual. The greatest observed increase in blood and exhaled breath THM concentration in any participant was due to showering (direct and indirect), bathing, and hand dishwashing. Average increase in blood THM concentration ranged from 57 to 358 pg/mL due to these activities. More research is needed to determine whether acute and frequent exposures to THM at these concentrations have public health implications. Further research is also needed in designing epidemiologic studies that minimize data collection burden yet maximize accuracy in classification of dermal and inhalation THM exposure during hot water use activities.
Nuckols, John R.; Ashley, David L.; Lyu, Christopher; Gordon, Sydney M.; Hinckley, Alison F.; Singer, Philip
2005-01-01
Individual exposure to trihalomethanes (THMs) in tap water can occur through ingestion, inhalation, or dermal exposure. Studies indicate that activities associated with inhaled or dermal exposure routes result in a greater increase in blood THM concentration than does ingestion. We measured blood and exhaled air concentrations of THM as biomarkers of exposure to participants conducting 14 common household water use activities, including ingestion of hot and cold tap water beverages, showering, clothes washing, hand washing, bathing, dish washing, and indirect shower exposure. We conducted our study at a single residence in each of two water utility service areas, one with relatively high and the other low total THM in the residence tap water. To maintain a consistent exposure environment for seven participants, we controlled water use activities, exposure time, air exchange, water flow and temperature, and nonstudy THM sources to the indoor air. We collected reference samples for water supply and air (pre–water use activity), as well as tap water and ambient air samples. We collected blood samples before and after each activity and exhaled breath samples at baseline and postactivity. All hot water use activities yielded a 2-fold increase in blood or breath THM concentrations for at least one individual. The greatest observed increase in blood and exhaled breath THM concentration in any participant was due to showering (direct and indirect), bathing, and hand dishwashing. Average increase in blood THM concentration ranged from 57 to 358 pg/mL due to these activities. More research is needed to determine whether acute and frequent exposures to THM at these concentrations have public health implications. Further research is also needed in designing epidemiologic studies that minimize data collection burden yet maximize accuracy in classification of dermal and inhalation THM exposure during hot water use activities. PMID:16002374
Alarcon Falconi, Tania M; Kulinkina, Alexandra V; Mohan, Venkata Raghava; Francis, Mark R; Kattula, Deepthi; Sarkar, Rajiv; Ward, Honorine; Kang, Gagandeep; Balraj, Vinohar; Naumova, Elena N
2017-01-01
Municipal water sources in India have been found to be highly contaminated, with further water quality deterioration occurring during household storage. Quantifying water quality deterioration requires knowledge about the exact source tap and length of water storage at the household, which is not usually known. This study presents a methodology to link source and household stored water, and explores the effects of spatial assumptions on the association between tap-to-household water quality deterioration and enteric infections in two semi-urban slums of Vellore, India. To determine a possible water source for each household sample, we paired household and tap samples collected on the same day using three spatial approaches implemented in GIS: minimum Euclidean distance; minimum network distance; and inverse network-distance weighted average. Logistic and Poisson regression models were used to determine associations between water quality deterioration and household-level characteristics, and between diarrheal cases and water quality deterioration. On average, 60% of households had higher fecal coliform concentrations in household samples than at source taps. Only the weighted average approach detected a higher risk of water quality deterioration for households that do not purify water and that have animals in the home (RR=1.50 [1.03, 2.18], p=0.033); and showed that households with water quality deterioration were more likely to report diarrheal cases (OR=3.08 [1.21, 8.18], p=0.02). Studies to assess contamination between source and household are rare due to methodological challenges and high costs associated with collecting paired samples. Our study demonstrated it is possible to derive useful spatial links between samples post hoc; and that the pairing approach affects the conclusions related to associations between enteric infections and water quality deterioration. Copyright © 2016 Elsevier GmbH. All rights reserved.
Agra, Har'el; Solodar, Ariel; Bawab, Omar; Levy, Shay; Kadas, Gyongyver J; Blaustein, Leon; Greenbaum, Noam
2018-08-15
Green roofs provide important ecosystem services in urban areas. In Mediterranean and other semi-arid climate regions, most perennial plants on green roofs need to be irrigated during the dry season. However, the use of freshwater in such regions is scarce. Therefore, the possibility of using grey water should be examined. Coal ash, produced primarily from the burning of coal in power plants, constitutes an environmental contaminant that should be disposed. One option is to use ash as a growing substrate for plants. Here, we compare the effects of irrigating with grey- versus tap-water and using ash versus perlite as growing substrates in green roofs. The study was conducted in northern Israel in a Mediterranean climate. The design was full factorial with three factors: water-type (grey or tap-water)×substrate-type (coal ash vs perlite)×plant species (Phyla nodiflora, Convolvulus mauritanicus or no-plant). The development of plants and the quality of drainage water along the season, as well as quality of the used substrates were monitored. Both plant species developed well under all the experimental conditions with no effect of water type or substrate type. Under all treatments, both plant species enhanced electrical conductivity (EC) and chemical oxygen demand (COD) of the drainage water. In the summer, EC and COD reached levels that are unacceptable in water and are intended to be reused for irrigation. We conclude that irrigating with grey water and using coal ash as a growth substrate can both be implemented in green roofs. The drainage from tap water as well as from grey water can be further used for irrigating the roof, but for that, COD and EC levels must be lowered by adding a sufficient amount of tap water before reusing. Copyright © 2018 Elsevier B.V. All rights reserved.
TIME TO PREGNANCY IN RELATION TO TOTAL TRIHALOMETHANE LEVELS IN TAP WATER
Time to pregnancy in relation to total trihalomethane levels in tap water
Shanna H. Swan, Cuirong Ren, Gayle C. Windham, Laura Fenster, Kirsten Waller. (University of Missouri and California Department of Health Services).
We have previously reported increased risks o...
9. Tower building. Hot water tap floor shown. Mixing vat ...
9. Tower building. Hot water tap floor shown. Mixing vat at center level. Juices mix and flow and left lower level. Copper kettles are down below view level. Looking toward front of building. - Tivoli-Union Brewery, 1320-1348 Tenth Street, Denver, Denver County, CO
[The toxicity variation of organic extracts in drinking water treatment processes].
Mei, M; Wei, S; Zijian, W; Wenhua, W; Baohua, Z; Suxia, Z
2001-01-01
Source water samples and outlet water samples from different treatment processes of the Beijing Ninth Water Works were concentrated in situ with XAD-2 filled columns. GC-MS analysis and toxic assessment including acute toxicity evaluation by luminescent bacterium bioassay(Q67 strains) and mutagenicity assessment by Ames test(TA98 and TA100 strains with and without S9 addition) were conducted on these samples. The results showed that prechlorination caused the direct and indirect frame shift mutagenicity as well as indirect base pair substitute mutagenicity. Addition of coagulant may increase the base pair substitute mutagenic effects greatly. Sand and coal filtration and granular activated carbon filtration could effectively remove most of the formed mutagens. The rechlorination do not obviously increase the mutagenic effects. No mutagenic effect was observed in tap water. Acute toxicity showed the same variation with that of mutagenicity during the treatment processes. Sample from flocculation treatment process was found to be the most toxic sample. Results of GC-MS analysis showed that water in this plant was not contaminated by PCB. Concentrations of toluene, naphthalene and phenol increased in flocculation treatment process and in tap water. However, the concentrations of these substances were at the level of microgram/L, therefore, were not high enough to cause mutagenicity.
NASA Astrophysics Data System (ADS)
Jameel, Yusuf; Brewer, Simon; Good, Stephen P.; Tipple, Brett J.; Ehleringer, James R.; Bowen, Gabriel J.
2016-08-01
Water extraction for anthropogenic use has become a major flux in the hydrological cycle. With increasing demand for water and challenges supplying it in the face of climate change, there is a pressing need to better understand connections between human populations, climate, water extraction, water use, and its impacts. To understand these connections, we collected and analyzed stable isotopic ratios of more than 800 urban tap water samples in a series of semiannual water surveys (spring and fall, 2013-2015) across the Salt Lake Valley (SLV) of northern Utah. Consistent with previous work, we found that mean tap water had a lower 2H and 18O concentration than local precipitation, highlighting the importance of nearby montane winter precipitation as source water for the region. However, we observed strong and structured spatiotemporal variation in tap water isotopic compositions across the region which we attribute to complex distribution systems, varying water management practices and multiple sources used across the valley. Water from different sources was not used uniformly throughout the area and we identified significant correlation between water source and demographic parameters including population and income. Isotopic mass balance indicated significant interannual and intra-annual variability in water losses within the distribution network due to evaporation from surface water resources supplying the SLV. Our results demonstrate the effectiveness of isotopes as an indicator of water management strategies and climate impacts within regional urban water systems, with potential utility for monitoring, regulation, forensic, and a range of water resource research.
Gortmaker, Steven L.; Long, Michael W.; Cradock, Angie L.; Kenney, Erica L.
2017-01-01
Objectives. To evaluate whether differences in tap water and other beverage intake explain differences in inadequate hydration among US adults by race/ethnicity and income. Methods. We estimated the prevalence of inadequate hydration (urine osmolality ≥ 800 mOsm/kg) by race/ethnicity and income of 8258 participants aged 20 to 74 years in the 2009 to 2012 National Health and Nutrition Examination Survey. Using multivariable regression models, we estimated associations between demographic variables, tap water intake, and inadequate hydration. Results. The prevalence of inadequate hydration among US adults was 29.5%. Non-Hispanic Blacks (adjusted odds ratio [AOR] = 1.44; 95% confidence interval [CI] = 1.17, 1.76) and Hispanics (AOR = 1.42; 95% CI = 1.21, 1.67) had a higher risk of inadequate hydration than did non-Hispanic Whites. Lower-income adults had a higher risk of inadequate hydration than did higher-income adults (AOR = 1.23; 95% CI = 1.04, 1.45). Differences in tap water intake partially attenuated racial/ethnic differences in hydration status. Differences in total beverage and other fluid intake further attenuated sociodemographic disparities. Conclusions. Racial/ethnic and socioeconomic disparities in inadequate hydration among US adults are related to differences in tap water and other beverage intake. Policy action is needed to ensure equitable access to healthy beverages. PMID:28727528
Brooks, Carolyn J; Gortmaker, Steven L; Long, Michael W; Cradock, Angie L; Kenney, Erica L
2017-09-01
To evaluate whether differences in tap water and other beverage intake explain differences in inadequate hydration among US adults by race/ethnicity and income. We estimated the prevalence of inadequate hydration (urine osmolality ≥ 800 mOsm/kg) by race/ethnicity and income of 8258 participants aged 20 to 74 years in the 2009 to 2012 National Health and Nutrition Examination Survey. Using multivariable regression models, we estimated associations between demographic variables, tap water intake, and inadequate hydration. The prevalence of inadequate hydration among US adults was 29.5%. Non-Hispanic Blacks (adjusted odds ratio [AOR] = 1.44; 95% confidence interval [CI] = 1.17, 1.76) and Hispanics (AOR = 1.42; 95% CI = 1.21, 1.67) had a higher risk of inadequate hydration than did non-Hispanic Whites. Lower-income adults had a higher risk of inadequate hydration than did higher-income adults (AOR = 1.23; 95% CI = 1.04, 1.45). Differences in tap water intake partially attenuated racial/ethnic differences in hydration status. Differences in total beverage and other fluid intake further attenuated sociodemographic disparities. Racial/ethnic and socioeconomic disparities in inadequate hydration among US adults are related to differences in tap water and other beverage intake. Policy action is needed to ensure equitable access to healthy beverages.
The changing pattern of ground-water development on Long Island, New York
Heath, Ralph C.; Foxworthy, B.L.; Cohen, Philip M.
1966-01-01
Ground-water development on Long Island has followed a pattern that has reflected changing population trends, attendant changes in the use and disposal of water, and the response of the hydrologic system to these changes. The historic pattern of development has ranged from individually owned shallow wells tapping glacial deposits to large-capacity public-supply wells tapping deep artesian aquifers. Sewage disposal has ranged from privately owned cesspools to modern large-capacity sewage-treatment plants discharging more than 70 mgd of water to the sea. At present (1965), different parts of long Island are characterized by different stages of ground-water development. In parts of Suffolk County in eastern long Island, development is similar to the earliest historical stages. Westward toward New York City, ground-water development becomes more intensive and complex, and the attendant problems become more acute. The alleviation of present problems and those that arise in the future will require management decisions based on the soundest possible knowledge of the hydrologic system, including an understanding of the factors involved in the changing pattern of ground-water development on the island.
NASA Astrophysics Data System (ADS)
Sako, A.; Yaro, J. M.; Bamba, O.
2018-06-01
This study investigates the hydrogeochemical and anthropogenic factors that control groundwater quality in an Upper Precambrian sedimentary aquifer in the northwestern Burkina Faso. The raw data and statistical and geochemical modeling results were used to identify the sources of major ions in dug well, private borewell and tap water samples. Tap waters were classified as Ca-HCO3 and Ca-Mg-HCO3 types, reflecting the weathering of the local dolomitic limestones and silicate minerals. Dug well waters, with a direct contact with various sources of contamination, were classified as Ca-Na-K-HCO3 type. Two factors that explain 94% of the total variance suggested that water-rock interaction was the most important factor controlling the groundwater chemistry. Factor 1 had high loadings on pH, Ca2+, Mg2+, HCO3 -, SO4 2- and TDS. These variables were also strongly correlated indicating their common geogenic sources. Based on the HCO3 -/(HCO3 - + SO4 2-) ratios (0.8-0.99), carbonic acid weathering appeared to control Ca2+, Mg2+, HCO3 - and SO4 2- acquisition in the groundwater. With relatively lower Ca2+ and Mg2+ concentrations, the majority of dug well and borewell waters were soft to moderately hard, whereas tap waters were considered very hard. Thus, the dug well and, to a lesser extent, borewell waters are likely to have a low buffering capacity. Factor 2 had high loadings on Na+, NO3 - and Cl-. The strong correlation between Na+ and NO3 - and Cl- implied that factor 2 represented the anthropogenic contribution to the groundwater chemistry. In contrast, K+ had moderate loadings on factors 1 and 2, consistent with its geogenic and anthropogenic sources. The study demonstrated that waters from dug wells and borewells were bacteriologically unsafe for human consumption, and their low buffering capacity may favor mobility of potentially toxic heavy metals in the aquifer. Not only very hard tap waters have aesthetic inconvenient, but their consumption may also pose health problems.
NASA Astrophysics Data System (ADS)
Hanzel, Adrienn; Horvát, Krisztina; Molics, Bálint; Berényi, Károly; Németh, Balázs; Szendi, Katalin; Varga, Csaba
2018-02-01
Since 1966, Szigetvár in Hungary is well recognised as a thermal spa. Many patients suffering from rheumatic diseases are treated with its thermal mineral water. Our objective was to investigate the effects of a 3-week-long outpatient balneotherapy-based rehabilitation program on patients suffering from osteoarthritis of the hips and the knees. During the treatment period, patients received a 30-min underwater jet massage in a bath tub, five times a week. One patient group received jet massage in a bath tub containing mineral water; the other group received the same treatment in tap water. Primary outcomes were measured by range of movement of the involved joints and Western Ontario and McMaster University Osteoarthritis Index (WOMAC). Visual analogue scale (VAS) was applied to measure current severity of pain. Furthermore, quality of life was assessed using the Short Form 36 questionnaire (SF-36). Range of movement (ROM) score, Western Ontario and McMaster University Osteoarthritis Index and visual analogue scale were determined before the first treatment, after the last treatment and 3 months after the last treatment. SF-36 questionnaire was filled in before the first and after the last treatment. Fifty patients (17 male, 33 female mean age 66.7 ± 4.79 years) were enrolled. After randomisation, patients were divided into two groups: tap water n = 24 and mineral water n = 26. Treatment with the thermal mineral water of Szigetvár significantly improved ROM, WOMAC scores, and SF-36-scored quality of life of the patients. Our double-blind study provided evidence for the beneficial health effects of another Hungarian thermal mineral water masking the colour, odour and pH of the tap water and mineral water.
Agócs, Tamás Zoltán; Puskás, István; Varga, Erzsébet; Molnár, Mónika
2016-01-01
Advanced oxidation processes (AOPs) are considered highly competitive water treatment technologies for the removal of organic pollutants. Among AOP techniques, photocatalysis has recently been the most widely studied. Our aims were to investigate how the dispersion of nanosized titanium dioxide (nanoTiO2) applied in photodegradation-based procedures can be stabilized with cyclodextrins in order to obtain a new, more efficient photocatalyst for the purification of waters polluted by xenobiotics applying UV irradiation. During our work, on the one hand, we studied the behavior and stability of nanoTiO2 in cyclodextrin solutions. On the other hand, we used various monomer and polymer cyclodextrin derivatives, and assessed the options for nanoTiO2 stabilization in the presence of various salts and tap water on the basis of turbidity tests. The physical stability of nanoTiO2 dispersions is diminished in the presence of the salts found in tap water (and occurring also in surface waters and ground water) and they are precipitated immediately. This colloidal instability can be improved by cyclodextrin derivatives. Based on the results of our studies we have selected carboxymethyl β-cyclodextrin polymer (CMBCD-P) for stabilization of nanoTiO2 dispersions. The photocatalytic degradation of methylene blue and ibuprofen as model organic pollutants in various media (distilled water, NaCl solution and tap water) has been studied using nanoTiO2 as catalyst stabilized by CMBCD-P. CMBCD-P itself showed a catalytic effect on the UV degradation of methylene blue. In addition to enhancing the colloid stability of nanoTiO2 CMBCD-P showed also synergistic effects in catalyzing the photodecomposition process of the dye. On the other hand, ibuprofen as a model pharmaceutical, a pollutant of emerging concern (EP), was protected by CMBCD-P against the photocatalytic degradation showing that inclusion complex formation can result in opposite effects depending on the structure of the host–guest complex. PMID:28144360
Agócs, Tamás Zoltán; Puskás, István; Varga, Erzsébet; Molnár, Mónika; Fenyvesi, Éva
2016-01-01
Advanced oxidation processes (AOPs) are considered highly competitive water treatment technologies for the removal of organic pollutants. Among AOP techniques, photocatalysis has recently been the most widely studied. Our aims were to investigate how the dispersion of nanosized titanium dioxide (nanoTiO 2 ) applied in photodegradation-based procedures can be stabilized with cyclodextrins in order to obtain a new, more efficient photocatalyst for the purification of waters polluted by xenobiotics applying UV irradiation. During our work, on the one hand, we studied the behavior and stability of nanoTiO 2 in cyclodextrin solutions. On the other hand, we used various monomer and polymer cyclodextrin derivatives, and assessed the options for nanoTiO 2 stabilization in the presence of various salts and tap water on the basis of turbidity tests. The physical stability of nanoTiO 2 dispersions is diminished in the presence of the salts found in tap water (and occurring also in surface waters and ground water) and they are precipitated immediately. This colloidal instability can be improved by cyclodextrin derivatives. Based on the results of our studies we have selected carboxymethyl β-cyclodextrin polymer (CMBCD-P) for stabilization of nanoTiO 2 dispersions. The photocatalytic degradation of methylene blue and ibuprofen as model organic pollutants in various media (distilled water, NaCl solution and tap water) has been studied using nanoTiO 2 as catalyst stabilized by CMBCD-P. CMBCD-P itself showed a catalytic effect on the UV degradation of methylene blue. In addition to enhancing the colloid stability of nanoTiO 2 CMBCD-P showed also synergistic effects in catalyzing the photodecomposition process of the dye. On the other hand, ibuprofen as a model pharmaceutical, a pollutant of emerging concern (EP), was protected by CMBCD-P against the photocatalytic degradation showing that inclusion complex formation can result in opposite effects depending on the structure of the host-guest complex.
Testing plant use of mobile vs immobile soil water sources using stable isotope experiments.
Vargas, Ana I; Schaffer, Bruce; Yuhong, Li; Sternberg, Leonel da Silveira Lobo
2017-07-01
We tested for isotope exchange between bound (immobile) and mobile soil water, and whether there is isotope fractionation during plant water uptake. These are critical assumptions to the formulation of the 'two water worlds' hypothesis based on isotope profiles of soil water. In two different soil types, soil-bound water in two sets of 19-l pots, each with a 2-yr-old avocado plant (Persea americana), were identically labeled with tap water. After which, one set received isotopically enriched water whereas the other set received tap water as the mobile phase water. After a dry down period, we analyzed plant stem water as a proxy for soil-bound water as well as total soil water by cryogenic distillation. Seventy-five to 95% of the bound water isotopically exchanged with the mobile water phase. In addition, plants discriminated against 18 O and 2 H during water uptake, and this discrimination is a function of the soil water loss and soil type. The present experiment shows that the assumptions for the 'two water worlds' hypothesis are not supported. We propose a novel explanation for the discrepancy between isotope ratios of the soil water profile and other water compartments in the hydrological cycle. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.
Furuhata, Katsunori; Kato, Yuko; Goto, Keiichi; Saitou, Keiko; Sugiyama, Jun-Ichi; Hara, Motonobu; Fukuyama, Masahumi
2007-06-01
Twenty-five yellow chromogenic strains isolated from hospital tap water samples collected nationwide were identified by partial 16S rDNA sequencing. In addition, the chlorine resistance of the isolates was experimentally investigated. The results showed that of the strains tested, 12 strains (48.0%) were Sphingomonas ursincola/natatoria, which was most frequently identified, followed by 2 strains (8.0%) of Mycobacterium frederiksbergense and 1 strain (4.0%) each of Sphingomonas adhaesiva, Sphingopyxis witflariensis and Porphyrobacter donghaensis. The other strains were not identified clearly but they belonged to the order of Alphaproteobacteria. On the other hand, the identification results by sequencing and biochemical property testing were not consistent in any of the strains, showing that it was difficult to accurately identify the yellow chromogenic bacteria in tap water based on only their biochemical properties. When the 25 isolates were exposed to 0.1 mg/l residual free chlorine for 1 minute, 22 isolates (88.0%) survived. When the CT (Concentration Time) value killing 99.99% of the bacteria was investigated in 6 of these survivors, M. frederiksbergense (Y-1 strain) was most resistant to chlorine with the CT value of 32 mg x min/l, followed by S. ursincola/natatoria (Y-7 strain) with the CT value of 3.3 mg x min/l. The CT values of Y-5 (Sphingomonas sp.), Y-27 (S. ursincola/natatoria) and Y-21 (Asticacaulis sp.) were within the range of 0.9-0.1 mg x min /l. Of the 6 strains, S. adhaesiva (Y-10) showed the weakest resistance with the CT value of 0.03 mg x min/l. It was clarified that most yellow chromogenic bacteria isolated from hospital tap water were Sphingomonas spp., and these bacteria were experimentally resistant to chlorine.
Ong, Kheng Yong; Lim, Wei Ching; Ooi, Shing Ming; Loh, Zhi Hui; Kong, Ming Chai; Chan, Lai Wah; Heng, Paul Wan Sia
2017-05-01
There are no commercially available nasal irrigation solutions containing corticosteroids. Instead, such preparations are extemporaneously prepared by adding existing corticosteroid formulations to nasal irrigation solutions. The stability of the corticosteroid betamethasone 17-valerate (B17V), in nasal irrigation solutions of different compositions and pH and stored under different temperatures, was studied to determine the optimal choice of solution and storage conditions. Triplicate extemporaneous preparations made with B17V were prepared by adding a predetermined volume of B17V lotion to each nasal irrigation solution: normal saline (NS), sodium bicarbonate (NaHCO 3 ) powder dissolved in tap water, and a commercially available powder mixture (FLO Sinus Care Powder), dissolved in tap water or pre-boiled tap water. Preparations were stored at 30°C and 4°C. Sampling was carried out at 0, 1, 2, 6, and 24 hours. The concentrations of B17V and its degradation compound, betamethasone 21-valerate (B21V), were determined by high-performance liquid chromatography. Preparations stored at 30°C contained a lower amount of B17V and higher amount of B21V than those stored at 4°C. B17V stability in nasal irrigation solutions decreased in the following order: NS, FLO in fresh tap water, FLO in pre-boiled tap water, and NaHCO 3 . The degradation rate of B17V increased with higher storage temperature and higher pH. B17V is most stable when added to NS and least stable in NaHCO 3 solution. FLO solution prepared with either cooled boiled water or tap water is an alternative if administered immediately. Storage at 4°C can better preserve stability of B17V, over a period of 24 hours. © 2017 ARS-AAOA, LLC.
TRIHALOMETHANE LEVELS IN HOME TAP WATER AND SEMEN QUALITY
Trihalomethane Levels in Home Tap Water and Semen Quality
Laura Fenster, 1 Kirsten Waller, 2 Gayle Windham, 1 Tanya Henneman, 2 Meredith Anderson, 2 Pauline Mendola, 3 James W. Overstreet, 4 Shanna H. Swan5
1California Department of Health Services, Division of Environm...
Determination of radon concentration in water using RAD7 with RAD H{sub 2}O accessories
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malik, M. F. I.; Rabaiee, N. A.; Jaafar, M. S.
In the last decade, the radon issue has become one of the major problems of radiation protection. Radon exposure occurs when using water for showering, washing dishes, cooking and drinking water. RAD7 and Rad H20 accessories were used in order to measure radon concentration in water sample. In this study, four types of water were concerns which are reverse osmosis (drinking water), mineral water, tap water and well water. Reverse osmosis (drinking water) and mineral water were bought from the nearest supermarket while tap water and well water were taken from selected areas of Pulau Pinang and Kedah. Total 20more » samples were taken with 5 samples for each type of water. The measured radon concentration ranged from 2.9±2.9 to 79.5±17 pCi/L, 2.9±2.9 to 67.8±16 pCi/L, 15.97±7 to 144.25±24 pCi/L and 374.89±37 to 6409.03±130 pCi/L in reverse osmosis (drinking water), mineral water, tap water and well water. Well water has the highest radon compared to others. It was due to their geological element such as granite. Results for all types of water are presented and compared with maximum contamination limit (MCL) recommended by United State Environmental Protection Agency (USEPA) which is 300pCi/L. Reverse osmosis water, mineral water and tap water were fall below MCL. However, well water was exceeded maximum level that was recommended. Thus, these findings were suggested that an action should be taken to reduce radon concentration level in well water as well as reduce a health risk towards the public.« less
Botsaris, George; Kanetis, Loukas; Slaný, Michal; Parpouna, Christiana; Makris, Konstantinos C
2015-12-01
Microorganisms can survive and multiply in aged urban drinking water distribution systems, leading to potential health risks. The objective of this work was to investigate the microbial quality of tap water and molecularly identify its predominant cultivable microorganisms. Tap water samples collected from 24 different households scattered in the urban area of Limassol, Cyprus, were microbiologically tested following standard protocols for coliforms, E. coli, Pseudomonas spp., Enterococcus spp., and total viable count at 22 and 37 °C. Molecular identification was performed on isolated predominant single colonies using 16SrRNA sequencing. Approximately 85% of the household water samples were contaminated with one or more microorganisms belonging to the genera of Pseudomonas, Corynebacterium, Agrobacterium, Staphylococcus, Bacillus, Delftia, Acinetobacter, Enterococcus, Enterobacter, and Aeromonas. However, all samples tested were free from E. coli. This is the first report in Cyprus molecularly confirming specific genera of relevant microbial communities in tap water.
Gorur, F Korkmaz; Camgoz, H
2014-10-01
The level of natural radioactivity for Bolu province of north-western Turkey was assessed in this study. There is no information about radioactivity measurement reported in water samples in the Bolu province so far. For this reason, gross α and β activities of 55 different water samples collected from tap, spring, mineral, river and lake waters in Bolu were determined. The mean activity concentrations were 68.11 mBq L(-1), 169.44 mBq L(-1) for gross α and β in tap water. For all samples the gross β activity is always higher than the gross α activity. All value of the gross α were lower than the limit value of 500 mBq L(-1) while two spring and one mineral water samples were found to have gross β activity concentrations of greater than 1000 mBq L(-1). The associated age-dependent dose from all water ingestion in Bolu was estimated. The total dose for adults had an average value exceeds the WHO recommended limit value. The risk levels from the direct ingestion of the natural radionuclides in tap and mineral water in Bolu were determinated. The mean (210)Po and (228)Ra risk the value of tap and mineral waters slightly exceeds what some consider on acceptable risk of 10(-4) or less. Copyright © 2014 Elsevier Ltd. All rights reserved.
Concentration of poliovirus from tap water using positively charged microporous filters.
Sobsey, M D; Jones, B L
1979-01-01
Microporous filters that are more electropositive than the negatively charged filters currently used for virus concentrations from water by filter adsorption-elution methods were evaluated for poliovirus recovery from tap water. Zeta Plus filters composed of diatomaceous earth-cellulose-"charge-modified" resin mixtures and having a net positive charge of up to pH 5 to 6 efficiently adsorbed poliovirus from tap water at ambient pH levels 7.0 to 7.5 without added multivalent cation salts. The adsorbed virus were eluted with glycine-NaOH, pH 9.5 to 11.5. Electropositive asbestos-cellulose filters efficiently adsorbed poliovirus from tap water without added multivalent cation salts between pH 3.5 and 9.0, and the absorbed viruses could be eluted with 3% beef extract, pH 9, but not with pH 9.5 to 11.5 glycine-NaOH. Under water quality conditions in which poliovirus recoveries from large volumes of water were less than 5% with conventional negatively charged filters and standard methods, recoveries with Zeta Plus filters averaged 64 and 22.5% for one- and two-stage concentration procedures, respectively. Electropositive filters appear to offer distinct advantages over conventional negatively charged filters for concentrating enteric viruses from water, and their behavior tends to confirm the importance of electrostatic forces in virus recovery from water by microporous filter adsorption-elution methods. PMID:36844
Growth of Dunaliella tertiolecta and associated bacteria in photobioreactors.
Lakaniemi, Aino-Maija; Intihar, Veera M; Tuovinen, Olli H; Puhakka, Jaakko A
2012-09-01
The aim of this study was to test three flat-plate photobioreactor configurations for cultivation of marine green alga Dunaliella tertiolecta under non-axenic growth conditions and to characterize and quantify the associated bacteria. The photobioreactor cultivations were conducted using tap water-based media. Static mixers intended to enhance mixing and light utilization did not generally increase algal growth at the low light intensities used. The maximum biomass concentration (measured as volatile suspended solids) and maximum specific growth rate achieved in the flat plate with no mixer were 2.9 g l⁻¹ and 1.3 day⁻¹, respectively. Based on quantitative polymerase chain reaction, bacterial growth followed the growth of D. tertiolecta. Based on 16S rDNA amplification and denaturing gradient gel electrophoresis profiling, heterotrophic bacteria in the D. tertiolecta cultures mainly originated from the non-axenic algal inocula, and tap water heterotrophs were not enriched in high chloride media (3 % salinity). Bacterial communities were relatively stable and reproducible in all flat-plate cultivations and were dominated by Gammaproteobacteria, Flavobacteria, and Alphaproteobacteria.
Eneh, Lynda K; Okal, Michael N; Borg-Karlson, Anna-Karin; Fillinger, Ulrike; Lindh, Jenny M
2016-05-12
A number of mosquito species in the Culex and Aedes genera prefer to lay eggs in Bermuda grass (Cynodon dactylon) hay infusions compared to water alone. These mosquitoes are attracted to volatile compounds from the hay infusions making the infusions effective baits in gravid traps used for monitoring vectors of arboviral and filarial pathogens. Since Bermuda grass is abundant and widespread, it is plausible to explore infusions made from it as a potential low cost bait for outdoor monitoring of the elusive malaria vector Anopheles gambiae s.s. This study investigated preferential egg laying of individual An. gambiae s.s. in hay infusion or in tap water treated with volatiles detected in hay infusion headspace compared to tap water alone, using two-choice egg-count bioassays. Infusions were prepared by mixing 90 g of dried Bermuda grass (hay) with 24 L of unchlorinated tap water in a bucket, and leaving it for 3 days at ambient temperature and humidity. The volatiles in the headspace of the hay infusion were sampled with Tenax TA traps for 20 h and analysed using gas chromatography coupled to mass spectrometry. In total, 18 volatiles were detected in the infusion headspace. Nine of the detected compounds and nonanal were selected for bioassays. Eight of the selected compounds have previously been suggested to attract/stimulate egg laying in An. gambiae s.s. Gravid females were significantly (p < 0.05) less likely to lay eggs in hay infusion dilutions of 25, 50 and 100 % and in tap water containing any of six compounds (3-methylbutanol, phenol, 4-methylphenol, nonanal, indole, and 3-methylindole) compared to tap water alone. The oviposition response to 10 % hay infusion or any one of the remaining four volatiles (4-hepten-1-ol, phenylmethanol, 2-phenylethanol, or 4-ethylphenol) did not differ from that in tap water. Anopheles gambiae s.s. prefers to lay eggs in tap water rather than Bermuda grass hay infusion. This avoidance of the hay infusion appears to be mediated by volatile organic compounds from the infusion. It is, therefore, unlikely that Bermuda grass hay infusion as formulated and used in gravid traps for Culex and Aedes mosquitoes will be suitable baits for monitoring gravid An. gambiae s.s.
NASA Astrophysics Data System (ADS)
Jameel, M. Y.; Bowen, G. J.
2015-12-01
Public water supply systems are the life-blood of urban areas. How we use urban water systems affects more than human health and well-being. Our water use can alter a city's energy balance, including how much solar energy is absorbed as heat or reflected back into space. The severity of these effects, and the need to better understand connections between climate, water extraction, water use, and water use impacts, is strongest in areas of climatic aridity and substantial land-use change, such as the rapidly urbanizing areas of Utah. We have gathered and analyzed stable water isotope data from a series of semi-annual hydrological surveys (spring and fall, 2013 and 2014) in urban tap water sampled across the Salt Lake Valley. Our study has led to four major findings thus far: 1) Clear and substantial variation in tap water isotopic composition in space and time that can be linked to different water sources and management practices within the urban area, 2) There is a strong correlation between the range of observed isotope values and the population of water districts, reflecting use of water from multiple local and non-local sources in districts with high water demand, 3) Water isotopes reflect significant and variable loss of water due to evaporation of surface water resources and 4) Overall, tap water contains lower concentrations of the heavy H and O isotopes than does precipitation within the basin, reflecting the connection between city water supplies and mountain water sources. Our results highlight the utility of isotopic data as an indicator of heterogeneities within urban water systems, management practices and their variation across a major metropolitan area, and effects of climate variability on urban water supplies
NASA Astrophysics Data System (ADS)
Olivia, Monita; Ismeddiyanto, Wibisono, Gunawan; Sitompul, Iskandar R.
2017-09-01
Construction in peatland has faced scarce water sources for mixing and curing concrete. It is known that peat water has high organic content and low pH that can be harmful to concrete in the environment. In some remote areas in Riau Province, contractors used peat water directly without sufficient treatments to comply with SKSNI requirements of concrete mixing water. This paper presents a study of compressive strength, porosity and sorptivity of Ordinary Portland Cement (OPC) and blended OPC-Palm Oil Fuel Ash (OPC-POFA) concrete. The specimens were mixed using natural water and peat water, then some of them were cured in fresh water and peat water. Six mixtures were investigated using a variation of cement, mixing water and curing water. Tap water is used as control mixing and curing water for all specimens. The compressive strength, porosity and sorptivity were calculated at seven and 28 days. Results indicate that the use of peat water will cause low compressive strength, high porosity and sorptivity for both OPC and OPC-POFA concrete. Using peat water and curing the specimens in tap water could improve the early strength, porosity and sorptivity of OPC concrete; however, it has an adverse effect on OPC-POFA specimens. The properties of early age concrete of both types (OPC and OPC-POFA) using peat water were as good as those with tap water. Therefore, it is suggested that peat water should be considered as mixing and curing water for concrete where tap water resources are scarce. Investigation of its long-term properties, as well as extending the observed age of concrete is recommended before any use of peat water.
Brown, Kathleen Ward; Gessesse, Bemnet; Butler, Lindsey J; MacIntosh, David L
2017-01-01
Numerous contemporary incidents demonstrate that conventional control strategies for municipal tap water have limited ability to mitigate exposures to chemicals whose sources are within distribution systems, such as lead, and chemicals that are not removed by standard treatment technologies, such as perfluorooctanoic acid (PFOA)/perfluorooctanesulfonic acid (PFOS). In these situations, point-of-use (POU) controls may be effective in mitigating exposures and managing health risks of chemicals in drinking water, but their potential utility has not been extensively examined. As an initial effort to fill this information gap, we conducted a critical review and analysis of the existing literature and data on the effectiveness of POU drinking water treatment technologies for reducing chemical contaminants commonly found in tap water in the United States. We found that many types of water treatment devices available to consumers in the United States have undergone laboratory testing and often certification for removal of chemical contaminants in tap water, but in most cases their efficacy in actual use has yet to be well characterized. In addition, the few studies of POU devices while “in use” focus on traditional contaminants regulated under the Safe Drinking Water Act, but do not generally consider nontraditional contaminants of concern, such as certain novel human carcinogens, industrial chemicals, pesticides, pharmaceuticals, personal care products, and flame retardants. Nevertheless, the limited information available at present suggests that POU devices can be highly effective when used prophylactically and when deployed in response to contamination incidents. Based on these findings, we identify future areas of research for assessing the ability of POU filters to reduce health-related chemical contaminants distributed through public water systems and private wells. PMID:29270018
Brown, Kathleen Ward; Gessesse, Bemnet; Butler, Lindsey J; MacIntosh, David L
2017-01-01
Numerous contemporary incidents demonstrate that conventional control strategies for municipal tap water have limited ability to mitigate exposures to chemicals whose sources are within distribution systems, such as lead, and chemicals that are not removed by standard treatment technologies, such as perfluorooctanoic acid (PFOA)/perfluorooctanesulfonic acid (PFOS). In these situations, point-of-use (POU) controls may be effective in mitigating exposures and managing health risks of chemicals in drinking water, but their potential utility has not been extensively examined. As an initial effort to fill this information gap, we conducted a critical review and analysis of the existing literature and data on the effectiveness of POU drinking water treatment technologies for reducing chemical contaminants commonly found in tap water in the United States. We found that many types of water treatment devices available to consumers in the United States have undergone laboratory testing and often certification for removal of chemical contaminants in tap water, but in most cases their efficacy in actual use has yet to be well characterized. In addition, the few studies of POU devices while "in use" focus on traditional contaminants regulated under the Safe Drinking Water Act, but do not generally consider nontraditional contaminants of concern, such as certain novel human carcinogens, industrial chemicals, pesticides, pharmaceuticals, personal care products, and flame retardants. Nevertheless, the limited information available at present suggests that POU devices can be highly effective when used prophylactically and when deployed in response to contamination incidents. Based on these findings, we identify future areas of research for assessing the ability of POU filters to reduce health-related chemical contaminants distributed through public water systems and private wells.
Bogart, Laura M; Cowgill, Burton O; Elliott, Marc N; Klein, David J; Hawes-Dawson, Jennifer; Uyeda, Kimberly; Elijah, Jacinta; Binkle, David G; Schuster, Mark A
2014-09-01
To conduct a randomized controlled trial of Students for Nutrition and eXercise, a 5-week middle school-based obesity-prevention intervention combining school-wide environmental changes, multimedia, encouragement to eat healthy school cafeteria foods, and peer-led education. We randomly selected schools (five intervention, five waitlist control) from the Los Angeles Unified School District. School records were obtained for number of fruits and vegetables served, students served lunch, and snacks sold per attending student, representing an average of 1,515 students (SD = 323) per intervention school and 1,524 students (SD = 266) per control school. A total of 2,997 seventh-graders (75% of seventh-graders across schools) completed pre- and postintervention surveys assessing psychosocial variables. Consistent with community-based participatory research principles, the school district was an equal partner, and a community advisory board provided critical input. Relative to control schools, intervention schools showed significant increases in the proportion of students served fruit and lunch and a significant decrease in the proportion of students buying snacks at school. Specifically, the intervention was associated with relative increases of 15.3% more fruits served (p = .006), 10.4% more lunches served (p < .001), and 11.9% fewer snacks sold (p < .001) than would have been expected in its absence. Pre-to-post intervention, intervention school students reported more positive attitudes about cafeteria food (p = .02) and tap water (p = .03), greater obesity-prevention knowledge (p = .006), increased intentions to drink water from the tap (p = .04) or a refillable bottle (p = .02), and greater tap water consumption (p = .04) compared with control school students. Multilevel school-based interventions may promote healthy adolescent dietary behaviors. Copyright © 2014 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.
Villanueva, Cristina M; Gracia-Lavedan, Esther; Bosetti, Cristina; Righi, Elena; Molina, Antonio José; Martín, Vicente; Boldo, Elena; Aragonés, Nuria; Perez-Gomez, Beatriz; Pollan, Marina; Acebo, Ines Gomez; Altzibar, Jone M; Zabala, Ana Jiménez; Ardanaz, Eva; Peiró, Rosana; Tardón, Adonina; Chirlaque, Maria Dolores; Tavani, Alessandra; Polesel, Jerry; Serraino, Diego; Pisa, Federica; Castaño-Vinyals, Gemma; Espinosa, Ana; Espejo-Herrera, Nadia; Palau, Margarita; Moreno, Victor; La Vecchia, Carlo; Aggazzotti, Gabriella; Nieuwenhuijsen, Mark J; Kogevinas, Manolis
2017-01-01
Evidence on the association between colorectal cancer and exposure to disinfection by-products in drinking water is inconsistent. We assessed long-term exposure to trihalomethanes (THMs), the most prevalent group of chlorination by-products, to evaluate the association with colorectal cancer. A multicenter case-control study was conducted in Spain and Italy in 2008-2013. Hospital-based incident cases and population-based (Spain) and hospital-based (Italy) controls were interviewed to ascertain residential histories, type of water consumed in each residence, frequency and duration of showering/bathing, and major recognized risk factors for colorectal cancer. We estimated adjusted odds ratios (OR) for colorectal cancer in association with quartiles of estimated average lifetime THM concentrations in each participant's residential tap water (micrograms/liter; from age 18 to 2 years before the interview) and estimated average lifetime THM ingestion from drinking residential tap water (micrograms/day). We analyzed 2,047 cases and 3,718 controls. Median values (ranges) for average lifetime residential tap water concentrations of total THMs, chloroform, and brominated THMs were 30 (0-174), 17 (0-63), and 9 (0-145) μg/L, respectively. Total THM concentration in residential tap water was not associated with colorectal cancer (OR = 0.92, 95% CI: 0.66, 1.28 for highest vs. lowest quartile), but chloroform concentrations were inversely associated (OR = 0.31, 95% CI: 0.24, 0.41 for highest vs. lowest quartile). Brominated THM concentrations showed a positive association among men in the highest versus the lowest quartile (OR = 1.43, 95% CI: 0.83, 2.46). Patterns of association were similar for estimated average THM ingestion through residential water consumption. We did not find clear evidence of an association between detailed estimates of lifetime total THM exposure and colorectal cancer in our large case-control study population. Negative associations with chloroform concentrations and ingestion suggest differences among specific THMs, but these findings should be confirmed in other study populations. Citation: Villanueva CM, Gracia-Lavedan E, Bosetti C, Righi E, Molina AJ, Martín V, Boldo E, Aragonés N, Perez-Gomez B, Pollan M, Gomez Acebo I, Altzibar JM, Jiménez Zabala A, Ardanaz E, Peiró R, Tardón A, Chirlaque MD, Tavani A, Polesel J, Serraino D, Pisa F, Castaño-Vinyals G, Espinosa A, Espejo-Herrera N, Palau M, Moreno V, La Vecchia C, Aggazzotti G, Nieuwenhuijsen MJ, Kogevinas M. 2017. Colorectal cancer and long-term exposure to trihalomethanes in drinking water: a multicenter case---control study in Spain and Italy. Environ Health Perspect 125:56-65; http://dx.doi.org/10.1289/EHP155.
Villanueva, Cristina M.; Gracia-Lavedan, Esther; Bosetti, Cristina; Righi, Elena; Molina, Antonio José; Martín, Vicente; Boldo, Elena; Aragonés, Nuria; Perez-Gomez, Beatriz; Pollan, Marina; Acebo, Ines Gomez; Altzibar, Jone M.; Zabala, Ana Jiménez; Ardanaz, Eva; Peiró, Rosana; Tardón, Adonina; Chirlaque, Maria Dolores; Tavani, Alessandra; Polesel, Jerry; Serraino, Diego; Pisa, Federica; Castaño-Vinyals, Gemma; Espinosa, Ana; Espejo-Herrera, Nadia; Palau, Margarita; Moreno, Victor; La Vecchia, Carlo; Aggazzotti, Gabriella; Nieuwenhuijsen, Mark J; Kogevinas, Manolis
2016-01-01
Background: Evidence on the association between colorectal cancer and exposure to disinfection by-products in drinking water is inconsistent. Objectives: We assessed long-term exposure to trihalomethanes (THMs), the most prevalent group of chlorination by-products, to evaluate the association with colorectal cancer. Methods: A multicenter case–control study was conducted in Spain and Italy in 2008–2013. Hospital-based incident cases and population-based (Spain) and hospital-based (Italy) controls were interviewed to ascertain residential histories, type of water consumed in each residence, frequency and duration of showering/bathing, and major recognized risk factors for colorectal cancer. We estimated adjusted odds ratios (OR) for colorectal cancer in association with quartiles of estimated average lifetime THM concentrations in each participant’s residential tap water (micrograms/liter; from age 18 to 2 years before the interview) and estimated average lifetime THM ingestion from drinking residential tap water (micrograms/day). Results: We analyzed 2,047 cases and 3,718 controls. Median values (ranges) for average lifetime residential tap water concentrations of total THMs, chloroform, and brominated THMs were 30 (0–174), 17 (0–63), and 9 (0–145) μg/L, respectively. Total THM concentration in residential tap water was not associated with colorectal cancer (OR = 0.92, 95% CI: 0.66, 1.28 for highest vs. lowest quartile), but chloroform concentrations were inversely associated (OR = 0.31, 95% CI: 0.24, 0.41 for highest vs. lowest quartile). Brominated THM concentrations showed a positive association among men in the highest versus the lowest quartile (OR = 1.43, 95% CI: 0.83, 2.46). Patterns of association were similar for estimated average THM ingestion through residential water consumption. Conclusions: We did not find clear evidence of an association between detailed estimates of lifetime total THM exposure and colorectal cancer in our large case–control study population. Negative associations with chloroform concentrations and ingestion suggest differences among specific THMs, but these findings should be confirmed in other study populations. Citation: Villanueva CM, Gracia-Lavedan E, Bosetti C, Righi E, Molina AJ, Martín V, Boldo E, Aragonés N, Perez-Gomez B, Pollan M, Gomez Acebo I, Altzibar JM, Jiménez Zabala A, Ardanaz E, Peiró R, Tardón A, Chirlaque MD, Tavani A, Polesel J, Serraino D, Pisa F, Castaño-Vinyals G, Espinosa A, Espejo-Herrera N, Palau M, Moreno V, La Vecchia C, Aggazzotti G, Nieuwenhuijsen MJ, Kogevinas M. 2017. Colorectal cancer and long-term exposure to trihalomethanes in drinking water: a multicenter case–––control study in Spain and Italy. Environ Health Perspect 125:56–65; http://dx.doi.org/10.1289/EHP155 PMID:27383820
Bai, Xiaohui; Zhi, Xinghua; Zhu, Huifeng; Meng, Mingqun; Zhang, Mingde
2015-01-01
This study investigates the effect of chloramine residual on bacteria growth and regrowth and the relationship between heterotrophic plate counts (HPCs) and the concentration of chloramine residual in the Shanghai drinking water distribution system (DWDS). In this study, models to control HPCs in the water distribution system and consumer taps are also developed. Real-time ArcGIS was applied to show the distribution and changed results of the chloramine residual concentration in the pipe system by using these models. Residual regression analysis was used to get a reasonable range of the threshold values that allows the chloramine residual to efficiently inhibit bacteria growth in the Shanghai DWDS; the threshold values should be between 0.45 and 0.5 mg/L in pipe water and 0.2 and 0.25 mg/L in tap water. The low residual chloramine value (0.05 mg/L) of the Chinese drinking water quality standard may pose a potential health risk for microorganisms that should be improved. Disinfection by-products (DBPs) were detected, but no health risk was identified.
Carignan, Courtney C; Karagas, Margaret R; Punshon, Tracy; Gilbert-Diamond, Diane; Cottingham, Kathryn L
2016-09-01
Arsenic is a carcinogen that can also affect the cardiac, respiratory, neurological and immune systems. Children have higher dietary arsenic exposure than adults owing to their more restricted diets and greater intake per unit body mass. We evaluated the potential contributions of breast milk and formula to arsenic exposure throughout the first year of life for 356 infants in the prospective New Hampshire Birth Cohort Study (NHBCS) using infant diets reported by telephone at 4, 8 and 12 months of age; measured household water arsenic concentrations; and literature data. Based on our central-tendency models, population-wide geometric mean (GM) estimated arsenic exposures in the NHBCS were relatively low, decreasing from 0.1 μg/kg/day at 4 months of age to 0.07 μg/kg/day at 12 months of age. At all three time points, exclusively formula-fed infants had GM arsenic exposures ~8 times higher than exclusively breastfed infants owing to arsenic in both tap water and formula powder. Estimated maximum exposures reached 9 μg/kg/day among exclusively formula-fed infants in households with high tap water arsenic (80 μg/l). Overall, modeled arsenic exposures via breast milk and formula were low throughout the first year of life, unless formula was prepared with arsenic-contaminated tap water.
Carignan, Courtney C.; Karagas, Margaret R.; Punshon, Tracy; Gilbert-Diamond, Diane; Cottingham, Kathryn L.
2016-01-01
Arsenic is a carcinogen that can also affect the cardiac, respiratory, neurological and immune systems. Children have higher dietary arsenic exposure than adults due to their more restricted diets and greater intake per unit body mass. We evaluated the potential contributions of breast milk and formula to arsenic exposure throughout the first year of life for 356 infants in the prospective New Hampshire Birth Cohort Study (NHBCS) using infant diets reported by telephone at 4, 8 and 12 months of age; measured household water arsenic concentrations; and literature data. Based on our central-tendency models, population-wide geometric mean (GM) estimated arsenic exposures in the NHBCS were relatively low, decreasing from 0.1 μg kg−1 d−1 at 4 months of age to 0.07 μg kg−1 d−1 at 12 months of age. At all three time points, exclusively formula-fed infants had GM arsenic exposures ~8 times higher than exclusively breastfed infants due to arsenic in both tap water and formula powder. Estimated maximum exposures reached 9 μg kg−1 d−1 among exclusively formula-fed infants in households with high tap water arsenic (80 μg/L). Overall, modeled arsenic exposures via breast milk and formula were low throughout the first year of life, unless formula was prepared with arsenic-contaminated tap water. PMID:26531802
40 CFR 141.80 - General requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and copper action levels measured in samples collected at consumers' taps. (c) Lead and copper action levels. (1) The lead action level is exceeded if the concentration of lead in more than 10 percent of tap... action level is exceeded if the concentration of copper in more than 10 percent of tap water samples...
Cast erosion from the cleaning of debris after the use of a cast trimmer.
Hansen, Paul A; Beatty, Mark W
2017-02-01
Whether using tap water to rinse off debris will make a clinical difference to the surface detail of a gypsum cast is unknown. In addition, how best to remove debris from the cast is unknown. The purpose of this in vitro study was to evaluate the efficiency of different methods of cleaning a gypsum cast after trimming and the effect of short-term exposure to tap water on the surface quality of the cast. A die fitting American National Standards Institute/American Dental Association specification 25 (International Standards Organization specification 6873) for dental gypsum products was embedded in a Dentoform with the machined lines positioned at the same level as the occlusal surface of the posterior teeth. A flat plate was used to ensure that the plane of occlusion for the die was at the same position as the posterior teeth. Forty polyvinyl siloxane impressions of the Dentoform were made and poured with vacuum-mixed improved Type IV dental stone. Each cast was inspected for the accurate reproduction of the lines. The base of the 2-stage pour was trimmed with a cast trimmer with water, and surface debris was removed by rinsing by hand under tap water for 10 seconds, by brushing the cast with a soft toothbrush for 10 seconds, or by resoaking the cast and using a soft camel hair brush in slurry water for 10 seconds. The amount of debris was evaluated on a scale of 1 to 4, and the quality of the 20-μm line was evaluated on a scale of 1 to 4 under ×15 magnification. The nonparametric Kruskal-Wallis ranks test was used to identify significant differences among the different cleaning methods (α=.05). Results of the Kruskal-Wallis and Kruskal-Wallis Z-value tests demonstrated that all cleaning methods produced cleaner casts than were observed for uncleansed controls (P<.001), but no differences in debris removal were found among the different cleaning methods (.065≤P≤.901). The ability to see the quality of a 20-μm line (P=.974) was not statistically different among the groups. Rinsing the cast under flowing tap water and brushing, or hand washing under flowing tap water, or using a soft camel hair brush in slurry water for 10 seconds had no noticeable effects on the quality of a 20-μm line, and all 3 methods resulted in a clean cast. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Predicting water filter and bottled water use in Appalachia: a community-scale case study.
Levêque, Jonas G; Burns, Robert C
2017-06-01
A questionnaire survey was conducted in order to assess residents' perceptions of water quality for drinking and recreational purposes in a mid-sized city in northcentral West Virginia. Two logistic regression analyses were conducted in order to investigate the factors that influence bottle use and filter use. Results show that 37% of respondents primarily use bottled water and that 58% use a household filter when drinking from the tap. Respondents with lower levels of environmental concern, education levels, and lower organoleptic perceptions were most likely to perceive health risks from tap water consumption, and were most likely to use bottled water. Income, age, and organoleptic perceptions were predictors of water filter use among respondents. Clean water for recreational purposes was not found to be significant with either of these models. Our results demonstrate that bottle use and filter use are explained differently. We argue that more education and better communication about local tap water quality would decrease the use of bottled water. We demonstrate that household filters could be used as an alternative to bottled water.
Lautenschlager, Karin; Boon, Nico; Wang, Yingying; Egli, Thomas; Hammes, Frederik
2010-09-01
Drinking water quality is routinely monitored in the distribution network but not inside households at the point of consumption. Fluctuating temperatures, residence times (stagnation), pipe materials and decreasing pipe diameters can promote bacterial growth in buildings. To test the influence of stagnation in households on the bacterial cell concentrations and composition, water was sampled from 10 separate households after overnight stagnation and after flushing the taps. Cell concentrations, measured by flow cytometry, increased (2-3-fold) in all water samples after stagnation. This increase was also observed in adenosine tri-phosphate (ATP) concentrations (2-18-fold) and heterotrophic plate counts (4-580-fold). An observed increase in cell biovolume and ATP-per-cell concentrations furthermore suggests that the increase in cell concentrations was due to microbial growth. After 5 min flushing of the taps, cell concentrations and water temperature decreased to the level generally found in the drinking water network. Denaturing gradient gel electrophoresis also showed a change in the microbial composition after stagnation. This study showed that water stagnation in household pipes results in considerable microbial changes. While hygienic risk was not directly assessed, it emphasizes the need for the development of good material validation methods, recommendations and spot tests for in-house water installations. However, a simple mitigation strategy would be a short flushing of taps prior to use. Copyright © 2010 Elsevier Ltd. All rights reserved.
AN INTEGRATED RESEARCH AGENDA TO EVALUATE TAP WATER DISINFECTION BYPRODUCTS AND HUMAN HEALTH: PART 1
An Integrated Research Agenda to Evaluate Tap Water Disinfection Byproducts and Human Health: Part I
Michele Lynberg1, David Ashley 2, Pauline Mendola3, J. R. Nuckols4, Kenneth Cantor5, Benjamin Blount 2, Philip Singer6, Charles Wilkes7, Lorraine Backer1, and Peter Langlo...
Wilhelm, M; Ohnesorge, F K
1990-01-01
The influence of storage temperature, vessel type, and treatment on alterations of aluminum (Al) concentrations in serum, urine, and dialysis fluid samples was studied at three different concentrations for each sample over an 18-month period. Furthermore, the influence of acidification on Al levels in tap water, urine, and dialysis fluid samples was studied over a four-month period. Al was measured by atomic absorption spectrometry. Sample storage in glass vessels was unsuitable, whereas only minor alterations of Al levels were observed with storage in polypropylene tubes, polystyrene tubes, and Monovettes. By using appropriate plastic containers, acid washing of the vessels showed no improvement. Frozen storage was superior compared with 4 degrees C, whereas storage at -80 degrees C offered no advantage compared with storage at -20 degrees C. Acidification of tap water samples was necessary to stabilize Al levels during storage. No striking effect of acidification on Al levels in urine and dialysis fluid samples was found. It is concluded that longterm storage of serum, urine, tap water, and dialysis fluid samples is possible if appropriate conditions are used.
Yen, Hung-Kai; Lin, Tsair-Fuh; Liao, Pao-Chi
2011-08-01
A solid-phase extraction (SPE)-liquid chromatography (LC)-mass spectrometry (MS) method was developed to concentrate and detect nine cyanotoxins simultaneously, including six microcystins (MCs) congeners, nodularin (NOD), anatoxin-a (ATX) and cylindrospermopsin (CYN), in pure and natural waters. A dual cartridge SPE assembly was tested for the operating parameters of cyanotoxin extraction. A surrogate standard (SS), 1,9-diaminononane, was spiked in all the samples before the SPE extraction, and an internal standard (IS), 2,3,5-trimethylphenyl methyl carbamate, was spiked before LC/MS analysis. The method detection limit (MDL) was 2-100 ng/L for nine cyanotoxins in pure water and was increased by a factor of three to ten in a more complicated water matrix. The recoveries based on SS were between 83 and 104%, while those based on IS were 80-120%. The developed method was successfully employed in analyzing 33 water samples collected from eutrophic lakes, water treatment plants and distribution taps. MCs, NOD, and CYN were detected in the reservoir water, with concentrations as high as 36 μg/L. In addition, for the first time in Taiwan's tap water, CYN was detected at concentrations as high as 8.6 μg/L. Quality control data for the field samples shows that the analytical scheme developed is appropriate for monitoring cyanotoxins. Copyright © 2011 Elsevier Ltd. All rights reserved.
Samadi, Nasrin; Abadian, Neda; Bakhtiari, Donya; Fazeli, Mohammad Reza; Jamalifar, Hossein
2009-07-01
Efficacy of commercial detergent and disinfectants to eliminate microorganisms associated with fresh vegetables eaten raw in Iran, including radish, parsley, basil, coriander (cilantro), Allium porrum (leek), and peppermint were studied. The raw vegetables were subjected to a triple wash treatment of washing in tap water for mud removal, washing in water containing a detergent (dishwashing liquid) or disinfectant individually, and rinsing in tap water. The population of total mesophilic microbes on the surface of untreated vegetables ranged from 10(5) to 10(6) CFU/g. Washing in tap water or treatment with detergent (333 ppm for 10 min) or benzalkonium chloride (92 ppm for 15 min) reduced the total microbial count, most probable number (MPN) of coliforms, MPN of fecal coliforms, and MPN of fecal streptococci by about 1.2 to 2.3 log. No significant differences in microbial populations were found on vegetables after decontamination with tap water, detergent, or benzalkonium chloride (P > 0.05). Treatments with peracetic acid (100 ppm for 15 min) and hydrogen peroxide (133 ppm for 30 min) reduced the total mesophilic microbial counts by about 2.8 log. The microbial reductions with calcium hypochlorite (300 ppm for 15 min) and combined hydrogen peroxide and silver ion (133 ppm for 30 min) were significantly higher than those obtained after rinsing in tap water or after detergent or benzalkonium chloride wash (P < 0.05). Pretreatment with detergent slightly enhanced the efficacy of all decontamination treatments, but results were not significantly different from those obtained after individual application of disinfectants.
Honeycutt, Jennifer A; Nguyen, Jenny Q T; Kentner, Amanda C; Brenhouse, Heather C
2017-05-01
Bisphenol A (BPA) is widely used in the polycarbonate plastics and epoxy resins that are found in laboratory animal husbandry materials including cages and water bottles. Concerns about BPA exposure in humans has led to investigations that suggest physiologic health risks including disruptions to the endocrine system and CNS. However, the extent of exposure of laboratory animals to BPA in drinking water is unclear. In the first study, we compared the amount of BPA contamination in water stored in plastic bottles used in research settings with that in glass bottles. The amount of BPA that leached into water was measured across several time points ranging from 24 to 96 h by using a BPA ELISA assay. The results showed that considerable amounts of BPA (approximately 0.15 μg/L) leached from polycarbonate bottles within the first 24 h of storage. In the second study, BPA levels were measured directly from water taken from filtered compared with unfiltered taps. We observed significantly higher BPA levels in water from unfiltered taps (approximately 0.40 μg/L) compared with taps with filtration systems (approximately 0.04 μg/L). Taken together, our findings indicate that the use of different types of water bottles and water sources, combined with the use of different laboratory products (food, caging systems) between laboratories, likely contribute to decreased rigor and reproducibility in research. We suggest that researchers consider reporting the types of water bottles used and that animal care facilities educate staff regarding the importance of flushing nonfiltered water taps when filling animal water bottles.
Honeycutt, Jennifer A; Nguyen, Jenny Q T; Kentner, Amanda C; Brenhouse, Heather C
2017-01-01
Bisphenol A (BPA) is widely used in the polycarbonate plastics and epoxy resins that are found in laboratory animal husbandry materials including cages and water bottles. Concerns about BPA exposure in humans has led to investigations that suggest physiologic health risks including disruptions to the endocrine system and CNS. However, the extent of exposure of laboratory animals to BPA in drinking water is unclear. In the first study, we compared the amount of BPA contamination in water stored in plastic bottles used in research settings with that in glass bottles. The amount of BPA that leached into water was measured across several time points ranging from 24 to 96 h by using a BPA ELISA assay. The results showed that considerable amounts of BPA (approximately 0.15 μg/L) leached from polycarbonate bottles within the first 24 h of storage. In the second study, BPA levels were measured directly from water taken from filtered compared with unfiltered taps. We observed significantly higher BPA levels in water from unfiltered taps (approximately 0.40 μg/L) compared with taps with filtration systems (approximately 0.04 μg/L). Taken together, our findings indicate that the use of different types of water bottles and water sources, combined with the use of different laboratory products (food, caging systems) between laboratories, likely contribute to decreased rigor and reproducibility in research. We suggest that researchers consider reporting the types of water bottles used and that animal care facilities educate staff regarding the importance of flushing nonfiltered water taps when filling animal water bottles. PMID:28535862
Gan, Zhiwei; Sun, Hongwen; Feng, Biting; Wang, Ruonan; Zhang, Yanwei
2013-09-15
Seventy water samples, including wastewaters, tap waters, fresh surface waters, coastal waters, groundwaters, and precipitation samples, from Tianjin, China, were analyzed for seven commonly used artificial sweeteners (ASs). The concentrations of the investigated ASs were generally in the order of wastewater treatment plant (WWTP) influent > WWTP effluent > surface water > tap water > groundwater ≈ precipitation, while the composition profiles of ASs varied in different waters. Acesulfame, sucralose, cyclamate, and saccharin were consistently detected in surface waters and ranged from 50 ng/L to 0.12 mg/L, while acesulfame was the dominant AS in surface and tap waters. Aspartame was found in all of the surface waters at a concentration up to 0.21 μg/L, but was not found in groundwaters and tap waters. Neotame and neohesperidin dihydrochalcone were less frequently detected and the concentrations were low. The concentrations of the ASs in some of the surface waters were of the same order with those in the WWTP influents, but not with the effluents, indicating there are probably untreated discharges into the surface waters. The ASs were detected in precipitation samples with high frequency, and acesulfame, saccharin, and cyclamate were the predominant ASs, with concentrations ranging from 3.5 ng/L to 1.3 μg/L. A gross estimation revealed that precipitation may act as a source for saccharin and cyclamate in the surface environment of Tianjin city. Moreover, the presence of ASs in the atmosphere was primarily assessed by taking 4 air samples to evaluate their potential source in precipitation. Copyright © 2013 Elsevier Ltd. All rights reserved.
Goldrath, Dara A.; Kulongoski, Justin T.; Davis, Tracy A.
2016-09-01
Groundwater quality in the 3,016-square-mile Monterey–Salinas Shallow Aquifer study unit was investigated by the U.S. Geological Survey (USGS) from October 2012 to May 2013 as part of the California State Water Resources Control Board Groundwater Ambient Monitoring and Assessment (GAMA) Program’s Priority Basin Project. The GAMA Monterey–Salinas Shallow Aquifer study was designed to provide a spatially unbiased assessment of untreated-groundwater quality in the shallow-aquifer systems in parts of Monterey and San Luis Obispo Counties and to facilitate statistically consistent comparisons of untreated-groundwater quality throughout California. The shallow-aquifer system in the Monterey–Salinas Shallow Aquifer study unit was defined as those parts of the aquifer system shallower than the perforated depth intervals of public-supply wells, which generally corresponds to the part of the aquifer system used by domestic wells. Groundwater quality in the shallow aquifers can differ from the quality in the deeper water-bearing zones; shallow groundwater can be more vulnerable to surficial contamination.Samples were collected from 170 sites that were selected by using a spatially distributed, randomized grid-based method. The study unit was divided into 4 study areas, each study area was divided into grid cells, and 1 well was sampled in each of the 100 grid cells (grid wells). The grid wells were domestic wells or wells with screen depths similar to those in nearby domestic wells. A greater spatial density of data was achieved in 2 of the study areas by dividing grid cells in those study areas into subcells, and in 70 subcells, samples were collected from exterior faucets at sites where there were domestic wells or wells with screen depths similar to those in nearby domestic wells (shallow-well tap sites).Field water-quality indicators (dissolved oxygen, water temperature, pH, and specific conductance) were measured, and samples for analysis of inorganic constituents (trace elements, nutrients, major and minor ions, silica, total dissolved solids, and alkalinity) were collected at all 170 sites. In addition to these constituents, the samples from grid wells were analyzed for organic constituents (volatile organic compounds, pesticides and pesticide degradates), constituents of special interest (perchlorate and N-nitrosodimethylamine, or NDMA), radioactive constituents (radon-222 and gross-alpha and gross-beta radioactivity), and geochemical and age-dating tracers (stable isotopes of carbon in dissolved inorganic carbon, carbon-14 abundances, stable isotopes of hydrogen and oxygen in water, and tritium activities).Three types of quality-control samples (blanks, replicates, and matrix spikes) were collected at up to 11 percent of the wells in the Monterey–Salinas Shallow Aquifer study unit, and the results for these samples were used to evaluate the quality of the data from the groundwater samples. With the exception of trace elements, blanks rarely contained detectable concentrations of any constituent, indicating that contamination from sample-collection procedures was not a significant source of bias in the data for the groundwater samples. Low concentrations of some trace elements were detected in blanks; therefore, the data were re-censored at higher reporting levels. Replicate samples generally were within the limits of acceptable analytical reproducibility. The median values of matrix-spike recoveries were within the acceptable range (70 to 130 percent) for the volatile organic compounds (VOCs) and N-nitrosodimethylamine (NDMA), but were only approximately 64 percent for pesticides and pesticide degradates.The sample-collection protocols used in this study were designed to obtain representative samples of groundwater. The quality of groundwater can differ from the quality of drinking water because water chemistry can change as a result of contact with plumbing systems or the atmosphere; because of treatment, disinfection, or blending with water from other sources; or some combination of these. Water quality in domestic wells is not regulated in California, however, to provide context for the water-quality data presented in this report, results were compared to benchmarks established for drinking-water quality. The primary comparison benchmarks were maximum contaminant levels established by the U.S. Environmental Protection Agency and the State of California (MCL-US and MCL-CA, respectively). Non-regulatory benchmarks were used for constituents without maximum contaminant levels (MCLs), including Health Based Screening Levels (HBSLs) developed by the USGS and State of California secondary maximum contaminant levels (SMCL-CA) and notification levels. Most constituents detected in samples from the Monterey–Salinas Shallow Aquifer study unit had concentrations less than their respective benchmarks.Of the 148 organic constituents analyzed in the 100 grid-well samples, 38 were detected, and all concentrations were less than the benchmarks. Volatile organic compounds were detected in 26 of the grid wells, and pesticides and pesticide degradates were detected in 28 grid wells. The special-interest constituent NDMA was detected above the HBSL in three samples, one of which also had a perchlorate concentration greater than the MCL-CA.Of the inorganic constituents, 6 were detected at concentrations above their respective MCL benchmarks in grid-well samples: arsenic (5 grid wells above the MCL of 10 micrograms per liter, μg/L), selenium (3 grid wells, MCL of 50 μg/L), uranium (4 grid wells, MCL of 30 μg/L), nitrate (16 grid wells, MCL of 10 milligrams per liter, mg/L), adjusted gross alpha particle activity (10 grid wells, MCL of 15 picocuries per liter, pCi/L), and gross beta particle activity (1 grid well, MCL of 50 pCi/L). An additional 4 inorganic constituents were detected at concentrations above their respective HBSL benchmarks in grid-well samples: boron (1 grid well above the HBSL of 6,000 μg/L), manganese (8 grid wells, HBSL of 300 μg/L), molybdenum (6 grid wells, HBSL of 40 μg/L), and strontium (6 grid wells, HBSL of 4,000 μg/L). Of the inorganic constituents, 4 were detected at concentrations above their non-health based SMCL benchmarks in grid-well samples: iron (9 grid wells above the SMCL of 300 μg/L), chloride (7 grid wells, SMCL of 500 mg/L), sulfate (14 grid wells, SMCL of 500 mg/L), and total dissolved solids (27 grid wells, SMCL of 1,000 mg/L).Of the inorganic constituents analyzed in the 70 shallow-well tap sites, 10 were detected at concentrations above the benchmarks. Of the inorganic constituents, 3 were detected at concentrations above their respective MCL benchmarks in shallow-well tap sites: arsenic (2 shallow-well tap sites above the MCL of 10 μg/L), uranium (2 shallow-well tap sites, MCL of 30 μg/L), and nitrate (24 shallow-well tap sites, MCL of 10 mg/L). An additional 3 inorganic constituents were detected above their respective HBSL benchmarks in shallow-well tap sites: manganese (4 shallow-well tap sites above the HBSL of 300 μg/L), molybdenum (4 shallow-well tap sites, HBSL of 40 μg/L), and zinc (2 shallow-well tap sites, HBSL of 2,000 μg/L). Of the inorganic constituents, 4 were detected at concentrations above their non-health based SMCL benchmarks in shallow-well tap sites: iron (6 shallow-well tap sites above the SMCL of 300 μg/L), chloride (1 shallow-well tap site, SMCL of 500 mg/L), sulfate (9 shallow-well tap sites, SMCL of 500 mg/L), and total dissolved solids (15 shallow-well tap sites, SMCL of 1,000 mg/L).
Vazquez Boucard, Celia; Lee-Cruz, Larisa; Mercier, Laurence; Ramírez Orozco, Martín; Serrano Pinto, Vania; Anguiano, Gerardo; Cazares, Linette; Díaz, Daniel
2017-10-01
Because of concerns that natural aquifers in the region of Todos Santos (Baja California Sur, Mexico) might be contaminated by organochlorine pesticides and heavy metals, a case-control study was conducted among consumers and non-consumers of well- and/or tap-water to determine risks to human health. This study was based on a genotoxic evaluation of buccal cells using the Comet assay technique. Levels of DNA damage in the consumers group were significantly higher than those of the control group. However, occupational exposure to genotoxicants showed to be the critical factor rather than water consumption. Taking into account the professions of well- and/or tap-water consumers, agricultural workers exposed directly (those who fumigated) or indirectly (those not involved in fumigating) to agrochemicals showed greater genetic damage than controls. This difference persisted even when age, and whether the person smoked or consumed alcoholic drinks were considered. These factors were not associated with the level of genetic damage observed. Chemical analyses of organochlorine pesticides and heavy metals were carried out to evaluate the water quality of wells, faucets, and surface water of canals consumed by the population and/or used for irrigation. High concentrations of α and β endosulfan were detected in water of surface canals. Although our inventory of agrochemicals employed in the region showed the use of products considered carcinogenic and/or mutagenic, they were not detected by the analytical techniques used. Heavy metals (arsenic, mercury, and lead) were detected in water of some wells used for irrigation and human consumption. Environ. Mol. Mutagen. 58:619-627, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Erosion of aluminum 6061-T6 under cavitation attack in mineral oil and water
NASA Technical Reports Server (NTRS)
Rao, B. C. S.; Buckley, D. H.
1985-01-01
Studies of the erosion of aluminum 6061-T6 under cavitation attack in distilled water, ordinary tap water and a viscous mineral oil are presented. The mean depth of penetration for the mineral oil was about 40 percent of that for water at the end of a 40 min test. The mean depth of penetration and its rate did not differ significantly for distilled and tap water. The mean depth of penetration rate for both distilled and tap water increased to a maximum and then decreased with test duration, while that for mineral oil had a maximum during the initial period. The ratio h/2a of the pit depth h to the pit diameter 2a varied from 0.04 to 0.13 in water and from 0.06 to 0.20 in mineral oil. Scanning electron microscopy indicates that the pits are initially formed over the grain boundaries and precipitates while the surface grains are deformed under cavitation attack.
Peruvian Arid Coast and Agriculture, South America
NASA Technical Reports Server (NTRS)
1991-01-01
The coast of Peru, between the Pacific Ocean and the Andes Mountains is very arid (16.5S, 72.5W). For several thousand years, water from numerous small streams has been used for traditional flood and canal irrigation agriculture. However, during the past decade innovative techniques have tapped new water sources for increased agricultural production. Ground water in the porous sedimentary rock formations has been tapped for well irrigation agriculture.
Lithium levels in tap water and psychotic experiences in a general population of adolescents.
Shimodera, Shinji; Koike, Shinsuke; Ando, Shuntaro; Yamasaki, Syudo; Fujito, Ryosuke; Endo, Kaori; Iijima, Yudai; Yamamoto, Yu; Morita, Masaya; Sawada, Ken; Ohara, Nobuki; Okazaki, Yuji; Nishida, Atsushi
2018-06-09
Recently, several epidemiologic studies have reported that lithium in drinking water may be associated with lower rates of suicide mortality, lower incidence of dementia, and lower levels of adolescents' depression and aggression at the population level. However, to our knowledge, no study has investigated lithium level in tap water in relation to psychotic experiences in a general population of adolescents. This is the first study to investigate this using a large dataset. Information on psychotic experiences, distress associated with these experiences, and depressive symptoms were collected in 24 public junior high schools in Kochi Prefecture in Japan. Samples were collected from sources that supplied drinking water to schools, and lithium levels were measured using atomic absorption spectrophotometry. The association of lithium levels with psychotic experiences, considering distress as a degree of severity, was examined using an ordinal logistic regression model with schools and depressive symptoms as random effects. In total, 3040 students responded to the self-reporting questionnaire (response rate: 91.8%). Lithium levels in tap water were inversely associated with psychotic experiences (p = 0.021). We concluded that lithium level in tap water was inversely associated with psychotic experiences among a general population of adolescents and may have a preventive effect for such experiences and distress. Copyright © 2018 Elsevier B.V. All rights reserved.
Sudanese refugees in Koboko: environmental health interventions.
Morgan, J
1994-02-01
The recounted experiences of an emergency support engineer revealed the importance of involving women in decision making at the local level. The task involved the provision of a gender sensitive technical program: a construction project to identify and supply safe, clean tap water for Sudanese refugees resettled in Uganda border areas where Ugandans had just returned as refugees in Zaire. There was squabbling among refugees because soap distribution was unsatisfactory, and a village elder revealed that corruption among elected officials was interfering with relief supplies. The village elder was able to notify an Oxfam spring technician, and other village women were consulted about suitable springs for providing permanent supplies during the dry season. Several springs were located, and one was selected. Six women helped prepare the spring for piped water, and, in the process, learned about spring technology. The location of tapstands was accomplished with village men and women mapping exact locations. Six taps were needed to serve a population of 100 people. Refugees helped with the digging of trenches, fixing the pipes, and assembling the tapstands. The operation took two weeks, but after the work was done, no one would use the tap water. A health educator consultant had to assure the villagers that the water was safe. Within days, villagers and refugees were using the tap water. Street theater was used to convey another health message about the importance of water tap maintenance. As a consequence, six men and women formed a sanitary committee to make certain the areas remained clean and well drained and that water was not wasted. Committee members were trained to make simple repairs. The lesson learned was that women can be effectively involved at the local level, if one listens intently, talks with women, and watches behavior carefully.
An urban, water-borne outbreak of diarrhoea and shigellosis in a district town in eastern India.
Saha, T; Murhekar, M; Hutin, Y J; Ramamurthy, T
2009-01-01
In September 2007, the Gayeshpur municipality reported a cluster of cases with diarrhoea. We aimed to identify the causative agent and the source of the disease. We defined a case as the occurrence of diarrhoea (> 3 loose stools/day) with fever or bloody stools in a resident of Gayeshpur in September-October 2007. We asked healthcare facilities to report cases, collected stool specimens from patients, constructed an epidemic curve, drew a map and calculated the incidence by age and sex. We also conducted a matched case-control study (58 in each group), calculated matched odds ratio (MOR) and population attributable fraction (PAF), as well as assessed the environment. We identified 461 cases (attack rate: 46/1000 population) and isolated Shigella flexneri (serotype 2a and 3a) from 3 of 4 stool specimens. The attack rate was higher among females (52/1000) and those in the age group of 45-59 years (71/1000). The outbreak started on 22 September, peaked multiple times and subsided on 12 October 2007. Cases were clustered distal to a leaking pipeline that crossed an open drain to intermittently supply non-chlorinated water to taps. The 58 cases and 58 controls were matched for age and sex. Drinking tap water (MOR: 10; 95% CI: 3-32; PAF: 89%), washing utensils in tap water (MOR: 3.7; 95% CI: 1.2-11.3) and bathing in tap water (MOR: 3.5; 95% CI: 1.1-11) were associated with the illness. This outbreak of diarrhoea and Shigella flexneri dysentery was caused by contamination of tap water and subsided following repair of the pipeline. We recommended regular chlorination of the water and maintenance of pipelines.
Katukiza, A Y; Ronteltap, M; van der Steen, P; Foppen, J W A; Lens, P N L
2014-02-01
To determine the magnitude of microbial risks from waterborne viruses and bacteria in Bwaise III in Kampala (Uganda), a typical slum in Sub-Saharan Africa. A quantitative microbial risk assessment (QMRA) was carried out to determine the magnitude of microbial risks from waterborne pathogens through various exposure pathways in Bwaise III in Kampala (Uganda). This was based on the concentration of Escherichia coli O157:H7, Salmonella spp., rotavirus (RV) and human adenoviruses F and G (HAdV) in spring water, tap water, surface water, grey water and contaminated soil samples. The total disease burden was 680 disability-adjusted life years (DALYs) per 1000 persons per year. The highest disease burden contribution was caused by exposure to surface water open drainage channels (39%) followed by exposure to grey water in tertiary drains (24%), storage containers (22%), unprotected springs (8%), contaminated soil (7%) and tap water (0.02%). The highest percentage of the mean estimated infections was caused by E. coli O157:H7 (41%) followed by HAdV (32%), RV (20%) and Salmonella spp. (7%). In addition, the highest infection risk was 1 caused by HAdV in surface water at the slum outlet, while the lowest infection risk was 2.71 × 10(-6) caused by E. coli O157:H7 in tap water. The results show that the slum environment is polluted, and the disease burden from each of the exposure routes in Bwaise III slum, with the exception of tap water, was much higher than the WHO reference level of tolerable risk of 1 × 10(-6) DALYs per person per year. The findings of this study provide guidance to governments, local authorities and nongovernment organizations in making decisions on measures to reduce infection risk and the disease burden by 10(2) to 10(5) depending on the source of exposure to achieve the desired health impacts. The infection risk may be reduced by sustainable management of human excreta and grey water, coupled with risk communication during hygiene awareness campaigns at household and community level. The data also provide a basis to make strategic investments to improve sanitary conditions in urban slums. © 2013 The Society for Applied Microbiology.
C. S., Lim; M. S., Shaharuddin; W. Y., Sam
2013-01-01
Introduction: A cross sectional study was conducted to estimate risk of exposure to lead via tap water ingestion pathway for the population of Seri Kembangan (SK). Methodology: By using purposive sampling method, 100 respondents who fulfilled the inclusive criteria were selected from different housing areas of SK based on geographical population distribution. Residents with filtration systems installed were excluded from the study. Questionnaires were administered to determine water consumption-related information and demographics. Two water samples (first-flushed and fully-flushed samples) were collected from kitchen tap of each household using HDPE bottles. A total of 200 water samples were collected and lead concentrations were determined using a Graphite Furnace Atomic Absorption Spectrophotometer (GFAAS). Results: Mean lead concentration in first-flushed samples was 3.041± SD 6.967µg/L and 1.064± SD 1.103µg/L for fully-flushed samples. Of the first-flushed samples, four (4) had exceeded the National Drinking Water Quality Standard (NDWQS) lead limit value of 10µg/L while none of the fully-flushed samples had lead concentration exceeded the limit. There was a significant difference between first-flushed samples and fully-flushed samples and flushing had elicited a significant change in lead concentration in the water (Z = -5.880, p<0.05). It was also found that lead concentration in both first-flushed and fully flushed samples was not significantly different across nine (9) areas of Seri Kembangan (p>0.05). Serdang Jaya was found to have the highest lead concentration in first-flushed water (mean= 10.44± SD 17.83µg/L) while Taman Universiti Indah had the highest lead concentration in fully-flushed water (mean=1.45± SD 1.83µg/L). Exposure assessment found that the mean chronic daily intake (CDI) was 0.028± SD 0.034µgday-1kg-1. None of the hazard quotient (HQ) value was found to be greater than 1. Conclusion: The overall quality of water supply in SK was satisfactory because most of the parameters tested in this study were within the range of permissible limit and only a few samples had exceeded the standard values for lead and pH. Non-carcinogenic risk attributed to ingestion of lead in SK tap water was found to be negligible. PMID:23445691
Lim, C S; Shaharuddin, M S; Sam, W Y
2012-11-21
A cross sectional study was conducted to estimate risk of exposure to lead via tap water ingestion pathway for the population of Seri Kembangan (SK). By using purposive sampling method, 100 respondents who fulfilled the inclusive criteria were selected from different housing areas of SK based on geographical population distribution. Residents with filtration systems installed were excluded from the study. Questionnaires were administered to determine water consumption-related information and demographics. Two water samples (first-flushed and fully-flushed samples) were collected from kitchen tap of each household using HDPE bottles. A total of 200 water samples were collected and lead concentrations were determined using a Graphite Furnace Atomic Absorption Spectrophotometer (GFAAS). Mean lead concentration in first-flushed samples was 3.041± SD 6.967µg/L and 1.064± SD 1.103µg/L for fully-flushed samples. Of the first-flushed samples, four (4) had exceeded the National Drinking Water Quality Standard (NDWQS) lead limit value of 10µg/L while none of the fully-flushed samples had lead concentration exceeded the limit. There was a significant difference between first-flushed samples and fully-flushed samples and flushing had elicited a significant change in lead concentration in the water (Z = -5.880, p<0.05). It was also found that lead concentration in both first-flushed and fully flushed samples was not significantly different across nine (9) areas of Seri Kembangan (p>0.05). Serdang Jaya was found to have the highest lead concentration in first-flushed water (mean= 10.44± SD 17.83µg/L) while Taman Universiti Indah had the highest lead concentration in fully-flushed water (mean=1.45± SD 1.83µg/L). Exposure assessment found that the mean chronic daily intake (CDI) was 0.028± SD 0.034µgday-1kg-1. None of the hazard quotient (HQ) value was found to be greater than 1. The overall quality of water supply in SK was satisfactory because most of the parameters tested in this study were within the range of permissible limit and only a few samples had exceeded the standard values for lead and pH. Non-carcinogenic risk attributed to ingestion of lead in SK tap water was found to be negligible.
Montiel-León, Juan Manuel; Duy, Sung Vo; Munoz, Gabriel; Amyot, Marc; Sauvé, Sébastien
2018-04-01
A study was initiated to investigate a fast and reliable method for the determination of selected systemic insecticides in water matrixes and to evaluate potential sources of bias in their analysis. Acetamiprid, clothianidin, desnitro-imidacloprid, dinotefuran, fipronil, imidacloprid, nitenpyram, thiacloprid, and thiamethoxam were amenable to analysis via on-line sample enrichment hyphenated to ultra-high-performance liquid chromatography tandem mass spectrometry. The selection of on-line solid-phase extraction parameters was dictated by a multicriterion desirability approach. A 2-mL on-line injection volume with a 1500 μL min -1 loading flow rate met the objectives sought in terms of chromatographic requirements, extraction efficiency, sensitivity, and precision. A total analysis time of 8 min per sample was obtained with method limits of detection in the range of 0.1-5 ng L -1 for the scope of targeted analytes. Automation at the sample concentration step yielded intraday and interday precisions in the range of 1-23 and 2-26%, respectively. Factors that could affect the whole method accuracy were further evaluated in matrix-specific experiments. The impact of the initial filtration step on analyte recovery was evaluated in ultra-pure water, tap water, and surface water. Out of the nine membranes tested, glass fiber filters and polyester filters appeared as the most appropriate materials. Sample storage stability was also investigated across the three matrix types; the targeted analytes displayed suitable stability during 28 days at either 4 °C or - 20 °C, with little deviations (± 10%) with respect to the initial T 0 concentration. Method applicability was demonstrated in a range of tap water and surface water samples from the province of Québec, Canada. Results from the present survey indicated a predominance of thiamethoxam (< 0.5-10 and 3-61 ng L -1 in tap water and river water, respectively), clothianidin (< 0.5-6 and 2-88 ng L -1 in tap water and river water, respectively), and imidacloprid (< 0.1-1 and 0.8-38 ng L -1 in tap water and river water, respectively) among the targeted analytes. Graphical abstract ᅟ Development of solid-phase extraction coupled on-line to UHPLC-MS/MS for the rapid screening of systemic insecticides in water.
Drinking water treatment is not associated with an observed increase in neural tube defects in mice
Melin, Vanessa E.; Johnstone, David W.; Etzkorn, Felicia A.
2018-01-01
Disinfection by-products (DBPs) arise when natural organic matter in source water reacts with disinfectants used in the water treatment process. Studies have suggested an association between DBPs and birth defects. Neural tube defects (NTDs) in embryos of untreated control mice were first observed in-house in May 2006 and have continued to date. The source of the NTD-inducing agent was previously determined to be a component of drinking water. Tap water samples from a variety of sources were analyzed for trihalomethanes (THMs) to determine if they were causing the malformations. NTDs were observed in CD-1 mice provided with treated and untreated surface water. Occurrence of NTDs varied by water source and treatment regimens. THMs were detected in tap water derived from surface water but not detected in tap water derived from a groundwater source. THMs were absent in untreated river water and laboratory purified waters, yet the percentage of NTDs in untreated river water were similar to the treated water counterpart. These findings indicate that THMs were not the primary cause of NTDs in the mice since the occurrence of NTDs was unrelated to drinking water disinfection. PMID:24497082
Kahlisch, Leila; Henne, Karsten; Gröbe, Lothar; Brettar, Ingrid; Höfle, Manfred G
2012-02-01
The question which bacterial species are present in water and if they are viable is essential for drinking water safety but also of general relevance in aquatic ecology. To approach this question we combined propidium iodide/SYTO9 staining ("live/dead staining" indicating membrane integrity), fluorescence-activated cell sorting (FACS) and community fingerprinting for the analysis of a set of tap water samples. Live/dead staining revealed that about half of the bacteria in the tap water had intact membranes. Molecular analysis using 16S rRNA and 16S rRNA gene-based single-strand conformation polymorphism (SSCP) fingerprints and sequencing of drinking water bacteria before and after FACS sorting revealed: (1) the DNA- and RNA-based overall community structure differed substantially, (2) the community retrieved from RNA and DNA reflected different bacterial species, classified as 53 phylotypes (with only two common phylotypes), (3) the percentage of phylotypes with intact membranes or damaged cells were comparable for RNA- and DNA-based analyses, and (4) the retrieved species were primarily of aquatic origin. The pronounced difference between phylotypes obtained from DNA extracts (dominated by Betaproteobacteria, Bacteroidetes, and Actinobacteria) and from RNA extracts (dominated by Alpha-, Beta-, Gammaproteobacteria, Bacteroidetes, and Cyanobacteria) demonstrate the relevance of concomitant RNA and DNA analyses for drinking water studies. Unexpected was that a comparable fraction (about 21%) of phylotypes with membrane-injured cells was observed for DNA- and RNA-based analyses, contradicting the current understanding that RNA-based analyses represent the actively growing fraction of the bacterial community. Overall, we think that this combined approach provides an interesting tool for a concomitant phylogenetic and viability analysis of bacterial species of drinking water.
Giebułtowicz, Joanna; Nałęcz-Jawecki, Grzegorz
2014-06-01
Antidepressants, even at low concentrations, can reveal some adverse effects on aquatic life due to disturbing homeostasis throughout the central and peripheral nervous system both in vertebrates and invertebrates. To date there have not been any reports regarding the presence of these pharmaceuticals in surface and tap waters in Eastern Europe. Therefore the aim of this study was to determine the presence of 21 antidepressant pharmaceuticals at specific points of the main Polish river - the Vistula, a smaller river of the Warsaw region - the Utrata, as well as in tap water samples of Warsaw. Samples were collected twice at one month intervals and analysed using solid-phase extraction (SPE) technique coupled with the liquid chromatography-electrospray ionisation-tandem mass spectrometer (LC-MS/MS) method operated under the multiple reaction monitoring mode (MRM). This is the first study where active compounds such as moclobemid or trazodone in the environment have been investigated. Environmental risk assessment of antidepressants in Poland was estimated on the basis of annuals sale data extracted from the NFZ (Narodowy Fundusz Zdrowia-National Health Service) base of reimbursed pharmaceuticals(1). Predicted environmental concentration (PEC) of target pharmaceuticals were compared with their measured concentration (MEC). Moreover, the application of the EMEA/CHMP guideline for environmental risk assessment of the antidepressants was discussed. The highest concentration of antidepressants was observed in the small river Utrata. In tap water only trace amounts of antidepressants including citalopram (up to 1.5ng/l), mianserin (up to 0.9ng/l), sertraline (<3.1ng/l), moclobemid (up to 0.3ng/l) and venlafaxine (up to 1.9ng/l) were detected. However this highlights their inadequate elimination in the drinking waste treatment facility. The presence of antidepressants in drinking water and the aquatic environment could have long-term effects even at low exposure level, especially since synergy amongst pharmaceutical pollutants may occur. Copyright © 2014 Elsevier Inc. All rights reserved.
Kim, Un-Jung; Kannan, Kurunthachalam
2018-04-27
The occurrence and profiles of 14 triester organophosphate flame retardants (OPFRs) and plasticizers were investigated in surface water, tap water, rainwater, and seawater collected from New York State. In total, 150 samples collected from rivers ( n = 35), lakes ( n = 39), tap water ( n = 58), precipitation/rainwater ( n = 15), and seawater ( n = 3) were analyzed for 14 organophosphate esters (OPEs). An additional nine Hudson River water samples were collected periodically to delineate seasonal trends in OPE levels. The total concentrations of OPEs were found at part-per-trillion ranges, with average concentrations that ranged from 0.01 ng/L for tripropyl phosphate (TPP) in river water to 689 ng/L for tris(2-butoxyethyl)phosphate (TBOEP) in lake water. Tris(1-chloro-2-propyl)phosphate (TCIPP) was the most abundant compound among the investigated OPEs in all types of water. The concentrations of OPEs in river-, lake-, and rainwater were similar but >3 times higher than those found in tap water. Chlorinated alkyl OPFRs accounted for a major proportion of total concentrations. TCIPP, TBOEP, and triethyl phosphate (TEP) were found in >90% of the samples analyzed. Wet deposition fluxes for 14 OPFRs were estimated, on the basis of the concentrations measured in rainwater in Albany, New York, and the values were between 440 and 5250 ng/m 2 . Among several surface water bodies analyzed, samples from the Hudson River and Onondaga Lake contained elevated concentrations of OPEs. Estimated daily intake of OPEs via the ingestion of drinking water was up to 9.65 ng/kg body weight/day.
Drinking water quality assessment.
Aryal, J; Gautam, B; Sapkota, N
2012-09-01
Drinking water quality is the great public health concern because it is a major risk factor for high incidence of diarrheal diseases in Nepal. In the recent years, the prevalence rate of diarrhoea has been found the highest in Myagdi district. This study was carried out to assess the quality of drinking water from different natural sources, reservoirs and collection taps at Arthunge VDC of Myagdi district. A cross-sectional study was carried out using random sampling method in Arthunge VDC of Myagdi district from January to June,2010. 84 water samples representing natural sources, reservoirs and collection taps from the study area were collected. The physico-chemical and microbiological analysis was performed following standards technique set by APHA 1998 and statistical analysis was carried out using SPSS 11.5. The result was also compared with national and WHO guidelines. Out of 84 water samples (from natural source, reservoirs and tap water) analyzed, drinking water quality parameters (except arsenic and total coliform) of all water samples was found to be within the WHO standards and national standards.15.48% of water samples showed pH (13) higher than the WHO permissible guideline values. Similarly, 85.71% of water samples showed higher Arsenic value (72) than WHO value. Further, the statistical analysis showed no significant difference (P<0.05) of physico-chemical parameters and total coliform count of drinking water for collection taps water samples of winter (January, 2010) and summer (June, 2010). The microbiological examination of water samples revealed the presence of total coliform in 86.90% of water samples. The results obtained from physico-chemical analysis of water samples were within national standard and WHO standards except arsenic. The study also found the coliform contamination to be the key problem with drinking water.
Jie, Yu; Jie, Zhou; Ya, Luo; Xuesong, Yang; Jing, Yang; Yu, Yang; Jiaqi, Yang; Jie, Xu
2017-06-01
Nonylphenol (NP) has provoked much environmental concern because of their weak estrogenic activities; however, few data are available on the environmental levels of the chemical in China. Environmental or river samples were assayed for NP by high-performance liquid chromatography (HPLC) technique. The concentration for NP measured in Xiangjiang River, ranging from 0.174 to 3.411 μg/L with a mean value of 1.73 μg/L, was lower than the Water Quality Criteria for NP of the US (6.6 μg/L); however, the NP concentration was maintained at a higher level compare to the developed countries and other civil cities. NP concentration in downstream water was markedly higher than that both in midstream and upstream water. Tissue accumulation of NP was observed in aquatics. A ratio of mean concentration of NP in aquatic (chlamys farreri and hemiculter leucisculus) to that in river water was 241 and 1087, respectively. The presence of NP in tap water in two urban districts of Zunyi was common with a detectable rate reached 100.0%. Mean NP concentration in terminal tap water in Huichuan district was six times as high as Honghuagang district, which was above Standards for the Drinking Water Quality for Phenols of China (2 μg/L). The pollution of NP in Xiangjiang River, tap water, and aquatic in Zunyi belongs to moderate or severe level in the world.
Kish, G.R.; Macy, J.A.; Mueller, R.T.
1987-01-01
The U.S. Geological Survey analyzed trace metal concentrations in tap water from domestic wells in newly constructed homes in Berkeley Township, Ocean County and Galloway Township, Atlantic County, N. J. The potable water distribution systems in all of the homes sampled are constructed primarily of copper with lead-based solder points. Home water treatment is used in Berkeley Township but not in Galloway Township. Tap water was collected after the water had been standing in the pipes overnight. In Berkeley, 6 to 11 samples exceeded both the U.S. Environmental Protection Agency 's primary drinking water regulation (DWR) for lead (50 microgram/L) and the secondary drinking water regulation (SDWR) for copper (1,000 microgram/L). In Galloway, 12 of 14 samples exceeded the DWR for lead and 13 of 14 exceeded the SDWR for copper. After collecting the standing-water samples, the water was left running for 15 minutes and a second sample was collected. None of the running-water samples exceeded the regulations for lead or copper. Available data suggest a correlation between the residence time of soft, acidic groundwater in new home plumbing systems and elevated trace-metal concentrations in drinking water derived from domestic wells within the New Jersey Coastal Plain. (USGS)
... the following measures: Use a point-of-use filter Consider using point-of-use (per- 2 Bottled ... tap sonal use, end-of-tap, under sink) filters that remove particles one micrometer or less in ...
Dorman, James W; Steinberg, Spencer M
2010-02-01
We report here a derivatization headspace method for the analysis of inorganic iodine in water. Samples from Lake Mead, the Las Vegas Wash, and from Las Vegas tap water were examined. Lake Mead and the Las Vegas Wash contained a mixture of both iodide and iodate. The average concentration of total inorganic iodine (TII) for Lake Mead was approximately 90 nM with an iodide-to-iodate ratio of approximately 1. The TII concentration (approximately 160 nM) and the ratio of iodide to iodate were higher for the Las Vegas Wash (approximately 2). The TII concentration for tap water was close to that of Lake Mead (approximately 90 nM); however, tap water contained no detectable iodide as a result of ozonation and chlorine treatment which converts all of the iodide to iodate.
Goswami, Shyamaprosad; Manna, Abhishek; Paul, Sima; Quah, Ching Kheng; Fun, Hoong-Kun
2013-12-25
We have designed a chemodosimeter DPNO (weak fluorescence) which can be oxidized to HPNO (strong blue fluorescence) by OCl(-) with high selectivity and sensitivity in a ratiometric approach with a noticeably lower detection limit. The sensor could be useful for the detection of hypochlorites in tap water.
"Bottled or Tap?" A Controversy for Science, Economics, and Society
ERIC Educational Resources Information Center
Lapham, Steven S.
2009-01-01
Every year, Americans spend billions of dollars on bottled water. They purchase a bottle from the vending machine or buy a case at the grocery, no longer considering the water that's freely available from their taps. As consumers and as citizens, however, Americans should pause to study the personal and public consequences of this choice. In this…
Kassenga, Gabriel R
2007-03-01
The consumption of bottled and plastic-bagged drinking water in Tanzania has increased largely because of the deteriorating quality of tap water. It is uncertain whether these water products are safe for drinking. In this study, the microbiological quality of bottled and plastic-bagged drinking water sold in Dar es Salaam, Tanzania, was investigated. One hundred and thirty samples representing 13 brands of bottled water collected from shops, supermarkets and street vendors were analysed for total coliform and faecal coliform organisms as well as heterotrophic bacteria. These were compared with 61 samples of tap water. Heterotrophic bacteria were detected in 92% of the bottled water samples analysed. Total and faecal coliform bacteria were present in 4.6% and 3.6%, respectively, of samples analysed with a tendency for higher contamination rates in plastic-bagged drinking water. Microbiological quality of tap water was found to be worse compared with bottled water, with 49.2% and 26.2% of sampling points showing the presence of total coliform and faecal coliform organisms, respectively. The results suggest caution and vigilance to avert outbreaks of waterborne diseases from these types of drinking water.
Analysis of perfluoroalkyl substances in waters from Germany and Spain.
Llorca, Marta; Farré, Marinella; Picó, Yolanda; Müller, Jutta; Knepper, Thomas P; Barceló, Damià
2012-08-01
Water has been identified as one of the main routes of human exposure to perfluoroalkyl substances (PFASs). This work assessed the presence of 21 PFASs along the whole water cycle using a new fast and cost effective analytical method based on an online sample enrichment followed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The method was validated for different types of matrices (ultrapure water, tap water and treated wastewater). The quality parameters for the 21 selected compounds presented good limits of detection (LOD) and quantification (LOQ) ranging, in general, from 0.83-10 ng/L to 2.8-50 ng/L, respectively. The method was applied to assess the occurrence of PFASs in 148 water samples of different steps along the whole water cycle, including: mineral bottled water, tap water, river water and treated effluent wastewater, from Germany to Spain. In addition, in order to prove the good performance of the online analytical method, the analysis of PFASs was carried out in parallel using a method based on offline anionic solid phase extraction (SPE) followed by LC-MS/MS. Consistent results were obtained using both approaches. The more frequently found compounds were perfluoroalkyl acids, such as the perfluorobutanoic acid which was in the 54% of the tap water samples investigated with concentrations in the range between 2.4 and 27 ng/L, the perfluoroheptanoic acid (0.23-53 ng/L) and perfluorooctanoic acid (0.16-35 ng/L), and the sulphonate perfluorooctanesulfonate (0.04-258 ng/L) which was the second more frequent compound and also the compound found in with the higher concentration. It should be remarked that the 88% of the samples analyzed presented at least one of the compounds at quantifiable concentrations. In addition, PFASs including short chain compounds were proved to be prevalent in drinking water, and the 50% of the drinking water samples showed quantifiable concentrations of PFASs. It should be said that the great majority of the samples may not pose an immediate health risk to consumers, and just 6 of the drinking water samples presented concentrations of PFOS exceeding the Provisional Health Advisory (PHA) level established by the Office of Water from the USEPA for PFOS, which was set in 200 ng/L. Copyright © 2012 Elsevier B.V. All rights reserved.
Hot tap thermowell installation
NASA Technical Reports Server (NTRS)
Romero, C. A.
1971-01-01
System permits valve housings or other fillings to be installed in live steam lines or water pipes without interrupting their operation, thus eliminating current tapping restrictions. Two basic assemblies for installation under pressure are described.
Peres, Marco Aurélio; Antunes, José Leopoldo Fereira; Peres, Karen Glazer
2006-01-01
To assess socioeconomic differences between towns with and without water fluoridation, and to compare dental caries levels among socioeconomic strata in fluoridated and non-fluoridated areas. A countrywide survey of oral health performed in 2002-03 and comprising 34,550 children aged 12 years provided information about dental caries levels in 249 Brazilian towns. Socioeconomic indices, the coverage and the fluoride status of the water supply network of participating towns were also appraised. Multivariate regression models fitted the adjustment of dental caries levels and covariates to socioeconomic status and water supply. Inequalities in dental outcomes were compared in towns with and without fluoridated tap water. Better-off towns tended to present a higher coverage by the water supply network, and were more inclined to add fluoride. Fluoridated tap water was associated with an overall improved profile of caries, concurrent with an expressively larger inequality in the distribution of dental disease. Suppressing inequalities in the distribution of dental caries requires an expanded access to fluoridated tap water; a strategy that can be effective to foster further reductions in caries indices.
Martínez Hernández, Juan; López-Rodas, V; Costas, E
2009-05-01
An increasing number of people drink water from fresh water supply reservoirs. However, with the global change a lot of reservoirs become eutrophic, which facilitates the occurrence of toxin-producing cyanobacterial blooms. Microcystins (powerful hepatotoxic water-soluble heptapeptides) are the most important cyanobacterial toxins affecting humans. High doses of microcystins produce hepatic necrosis. Consequently, WHO Guidelines limit microcystins to 1 ppb in drinking waters. However, microcystins are present frequently in tap water at lower doses. Here, we hypothesized that chronic consume of tap water containing low doses of microcystins may be a risk factor for liver and colorectal cancer. Two kinds of evidences support this hypothesis. On one hand some epidemiological data (mainly in China). On the other hand, the molecular mechanism of microcystins toxicity (inhibition of protein phosphatases PP1 and PP2) is just like okadaic acid (a potent tumor promoter). Cancer risk from drinking water is certainly less than smoking, occupational exposures or some foods. But it is significant and with a rapid increase of toxic cyanobacterial blooms by eutrophycation, become more frequent.
Case study of complaints on drinking water quality: relationship to copper content?
Pizarro, Fernando; Araya, Magdalena; Vásquez, Marcela; Lagos, Gustavo; Olivares, Manuel; Méndez, Marco A; Leyton, Bárbara; Reyes, Arturo; Letelier, Victoria; Uauy, Ricardo
2007-05-01
Several families of Talca city, Chile complained to health authorities for what they attributed to consumption of copper (Cu)-contaminated drinking water. We assessed the situation 6-12 mo after the initiation of complaints by characterizing the symptoms reported, the chemistry of drinking water, and the Cu concentration in stagnant drinking water. After completing a census, 1778 households accepted participation and were categorized as follows: category 1, Cu plumbing for tap water and dwellers reporting health complaints (HC); category 2, Cu plumbing for tap water and dwellers reporting no HC; category 3, plastic plumbing for tap water and dwellers reporting no HC. Questionnaires recorded characteristics of households and symptoms presented by each member of the family in the last 3 mo. The Cu concentration in drinking water was measured in a subsample of 80 homes with Cu pipes. In category 1, participants presented significantly more abdominal pain, diarrhea, and/or vomiting (gastrointestinal [GI] symptoms) in comparison to category 3 and to categories 2 plus 3. The stagnant Cu concentrations measured in drinking water in all houses studied were below the US Environmental Protection Agency guideline value (<1.3 mg Cu/L). In summary, data obtained by interviews suggested that individuals in some areas of Talca city were suffering more GI symptoms potentially related to Cu excess, but measurement of Cu concentration in stagnant tap waters ruled out the association between Cu exposure and GI symptom reports at the time of this study. The dose-response curves for GI symptoms and Cu exposure now available were crucial in the analyses of results.
Giebułtowicz, Joanna; Stankiewicz, Albert; Wroczyński, Piotr; Nałęcz-Jawecki, Grzegorz
2016-12-01
In recent years, cardiovascular diseases were the second most common cause of death worldwide. Therefore, the consumption of drugs used to treat cardiovascular diseases is high. So far, there were no such comprehensive reports regarding the presence of cardiovascular drugs in surface and tap waters, particularly in Central and Eastern Europe. The aim of our study was to determine the presence of 30 pharmaceutically active compounds and some of their metabolites, at specific points of the Vistula River and in tap water samples in the Warsaw region. The analysis was performed using the liquid chromatography-electrospray ionization-tandem mass spectrometry method, coupled to solid-phase extraction. To the best of the authors' knowledge, this is the first time where the presence of ciprofibrate in the environment was investigated. Cardiovascular drugs found at the highest concentrations (reaching 1 μg/L or higher) in surface water were beta-blockers, sartans and diuretics. In tap water samples, trace amounts of pharmaceuticals were detected, for almost all target compounds. This highlights their inadequate elimination by the treatment facility used in the Warsaw region. The presence of cardiovascular compounds in the aquatic environment could have a long-term effect even at a low exposure level, since synergy effects amongst pharmaceuticals may occur.
Wilhelmsson, Per K I; Mühlich, Cornelia; Ullrich, Kristian K
2017-01-01
Abstract Plant genomes encode many lineage-specific, unique transcription factors. Expansion of such gene families has been previously found to coincide with the evolution of morphological complexity, although comparative analyses have been hampered by severe sampling bias. Here, we make use of the recently increased availability of plant genomes. We have updated and expanded previous rule sets for domain-based classification of transcription associated proteins (TAPs), comprising transcription factors and transcriptional regulators. The genome-wide annotation of these protein families has been analyzed and made available via the novel TAPscan web interface. We find that many TAP families previously thought to be specific for land plants actually evolved in streptophyte (charophyte) algae; 26 out of 36 TAP family gains are inferred to have occurred in the common ancestor of the Streptophyta (uniting the land plants—Embryophyta—with their closest algal relatives). In contrast, expansions of TAP families were found to occur throughout streptophyte evolution. 17 out of 76 expansion events were found to be common to all land plants and thus probably evolved concomitant with the water-to-land-transition. PMID:29216360
Beneficial effect of sulphate-bicarbonate-calcium water on gallstone risk and weight control.
Corradini, Stefano Ginanni; Ferri, Flaminia; Mordenti, Michela; Iuliano, Luigi; Siciliano, Maria; Burza, Maria Antonella; Sordi, Bruno; Caciotti, Barbara; Pacini, Maria; Poli, Edoardo; Santis, Adriano De; Roda, Aldo; Colliva, Carolina; Simoni, Patrizia; Attili, Adolfo Francesco
2012-03-07
To investigate the effect of drinking sulphate-bicarbonate-calcium thermal water (TW) on risk factors for atherosclerosis and cholesterol gallstone disease. Postmenopausal women with functional dyspepsia and/or constipation underwent a 12 d cycle of thermal (n = 20) or tap (n = 20) water controlled drinking. Gallbladder fasting volume at ultrasound, blood vitamin E, oxysterols (7-β-hydroxycholesterol and 7-ketocholesterol), bile acid (BA), triglycerides, total/low density lipoprotein and high density lipoprotein cholesterol were measured at baseline and at the end of the study. Food consumption, stool frequency and body weight were recorded daily. Blood lipids, oxysterols and vitamin E were not affected by either thermal or tap water consumption. Fasting gallbladder volume was significantly (P < 0.005) smaller at the end of the study than at baseline in the TW (15.7 ± 1.1 mL vs 20.1 ± 1.7 mL) but not in the tap water group (19.0 ± 1.4 mL vs 19.4 ± 1.5 mL). Total serum BA concentration was significantly (P < 0.05) higher at the end of the study than at baseline in the TW (5.83 ± 1.24 μmol vs 4.25 ± 1.00 μmol) but not in the tap water group (3.41 ± 0.46 μmol vs 2.91 ± 0.56 μmol). The increased BA concentration after TW consumption was mainly accounted for by glycochenodeoxycholic acid. The number of pasta (P < 0.001), meat (P < 0.001) and vegetable (P < 0.005) portions consumed during the study and of bowel movements per day (P < 0.05) were significantly higher in the TW than in the tap water group. Body weight did not change at the end of the study as compared to baseline in both groups. Sulphate-bicarbonate-calcium water consumption has a positive effect on lithogenic risk and intestinal transit and allows maintenance of a stable body weight despite a high food intake.
Park, Se-Keun; Kim, Yeong-Kwan; Choi, Sung-Chan
2008-07-01
Consequences of orthophosphate addition for corrosion control in water distribution pipes with respect to microbial growth were investigated using batch and dynamic tests. Batch tests showed that the release of copper in either low or high organic carbon content water was decreased by 69% and 56% with addition 206 microg PO(4)-P, respectively. Dosing of orthophosphate against corrosion did not increase microbial growth potential in the water and in the biofilm in both corroded and uncorroded systems receiving tap water with a low content of organic carbon and of biodegradable organic fraction. However, in tap water having a high concentration of organic carbon from acetate addition, orthophosphate addition promoted the growth of bacteria, allowed more bacteria to assemble on corroded and uncorroded surfaces, and increased the consumption of organic carbon. Orthophosphate consumption did not exceed 1% of the amount of easily biodegradable organic carbon required for microbial growth, and the orthophosphate demand for corrosion control greatly exceeded the nutritional requirement of microbial growth. The results of the dynamic tests demonstrated that there was a significant effect of interaction between biodegradable organic carbon and orthophosphate on biofilm growth, whereby the effect of orthophosphate flux on microbial growth was dependent on the levels of biodegradable organic carbon. Controlling an easily biodegradable organic carbon would be therefore necessary to minimize the microbial growth potential induced by orthophosphate-based anticorrosion treatment.
Concentration of enteric viruses from tap water using an anion exchange resin-based method.
Pérez-Méndez, A; Chandler, J C; Bisha, B; Goodridge, L D
2014-09-01
Detecting low concentrations of enteric viruses in water is needed for public health-related monitoring and control purposes. Thus, there is a need for sensitive, rapid and cost effective enteric viral concentration methods compatible with downstream molecular detection. Here, a virus concentration method based on adsorption of the virus to an anion exchange resin and direct isolation of nucleic acids is presented. Ten liter samples of tap water spiked with different concentrations (10-10,000 TCID50/10 L) of human adenovirus 40 (HAdV-40), hepatitis A virus (HAV) or rotavirus (RV) were concentrated and detected by real time PCR or real time RT-PCR. This method improved viral detection compared to direct testing of spiked water samples where the ΔCt was 12.1 for AdV-40 and 4.3 for HAV. Direct detection of RV in water was only possible for one of the three replicates tested (Ct of 37), but RV detection was improved using the resin method (all replicates tested positive with an average Ct of 30, n=3). The limit of detection of the method was 10 TCID50/10 L for HAdV-40 and HAV, and 100 TCID50/10 L of water for RV. These results compare favorably with detection limits reported for more expensive and laborious methods. Copyright © 2014 Elsevier B.V. All rights reserved.
Identification of Trihalomethanes (THMs) Levels in Water Supply: A Case Study in Perlis, Malaysia
NASA Astrophysics Data System (ADS)
Jalil, Mohd Faizal Ab; Hamidin, Nasrul; Anas Nagoor Gunny, Ahmad; Nihla Kamarudzaman, Ain
2018-03-01
In Malaysia, chlorination is used for drinking water disinfection at water treatment plants due to its cost-effectiveness and efficiency. However, the use of chlorine poses potential health risks due to the formation of disinfection by-products such as trihalomethanes (THMs). THMs are formed due to the reaction between chlorine and some natural organic matter. The objective of the study is to analyze the level of THMs in the water supply in Perlis, Malaysia. The water samples were collected from end-user tap water near the water treatment plant (WTP) located in Perlis, including Timah Tasoh WTP, Kampung Sungai Baru WTP, Arau Phase I, II, III, and IV WTPs. The THMs were analyzed using a Gas Chromatography-Mass Spectrometry (GC/MS). The results showed that the water supply from Timah Tasoh WTP generates the most THMs, whereas Kuala Sungai Baru shows the fewest amounts of total THMs. In conclusion, the presence of THMs in tap water has caused great concern since these components can cause cancer in humans. Therefore, the identification of THM formation is crucial in order to make sure that the tap water quality remains at acceptable safety levels.
Souza, B D M; Lückemeyer, D D; Reyes-Carmona, J F; Felippe, W T; Simões, C M O; Felippe, M C S
2011-02-01
To evaluate the effectiveness of various storage media at 5 °C for maintaining the viability of human periodontal ligament fibroblasts (PDLF). Plates with PDLF were soaked in recently prepared Hank's balanced salt solution (HBSS), skimmed milk, whole milk, Save-A-Tooth(®) system's HBSS (Save), natural coconut water, industrialized coconut water or tap water (negative control) at 5 °C for 3, 6, 24, 48, 72, 96 and 120 h. Minimum essential medium (MEM) at 37 °C served as the positive control. PDL cell viability was determined by MTT assay. Data were statistically analysed by Kruskal-Wallis test complemented by the Scheffé test (α=5%). The greatest number of viable cells was observed for MEM. Skimmed and whole milk, followed by natural coconut water and HBSS, were the most effective media in maintaining cell viability (P<0.05). From 24 to 120 h, Save, industrialized coconut water and tap water were the worst storage media. Skimmed and whole milk had the greatest capacity to maintain PDLF viability when compared with natural coconut water, HBSS, Save, industrialized coconut water and tap water. © 2010 International Endodontic Journal.
Lyons, Michael A.; Yang, Raymond S.H.; Mayeno, Arthur N.; Reisfeld, Brad
2008-01-01
Background One problem of interpreting population-based biomonitoring data is the reconstruction of corresponding external exposure in cases where no such data are available. Objectives We demonstrate the use of a computational framework that integrates physiologically based pharmacokinetic (PBPK) modeling, Bayesian inference, and Markov chain Monte Carlo simulation to obtain a population estimate of environmental chloroform source concentrations consistent with human biomonitoring data. The biomonitoring data consist of chloroform blood concentrations measured as part of the Third National Health and Nutrition Examination Survey (NHANES III), and for which no corresponding exposure data were collected. Methods We used a combined PBPK and shower exposure model to consider several routes and sources of exposure: ingestion of tap water, inhalation of ambient household air, and inhalation and dermal absorption while showering. We determined posterior distributions for chloroform concentration in tap water and ambient household air using U.S. Environmental Protection Agency Total Exposure Assessment Methodology (TEAM) data as prior distributions for the Bayesian analysis. Results Posterior distributions for exposure indicate that 95% of the population represented by the NHANES III data had likely chloroform exposures ≤ 67 μg/L in tap water and ≤ 0.02 μg/L in ambient household air. Conclusions Our results demonstrate the application of computer simulation to aid in the interpretation of human biomonitoring data in the context of the exposure–health evaluation–risk assessment continuum. These results should be considered as a demonstration of the method and can be improved with the addition of more detailed data. PMID:18709138
Compressive strength of marine material mixed concrete
NASA Astrophysics Data System (ADS)
Adnan; Parung, H.; Tjaronge, M. W.; Djamaluddin, R.
2017-11-01
Many cement factories have been incorporated fly ash with clinker cement to produce blended cement. PCC is a type of blended cement incorporated fly ash that produced in Indonesia cement factories. To promote the sustainable development in the remote islands this present paper attempted to study the suitability of sea water, marine sand that available abundantly surround the remote island with Portland Composite Cement (PCC) and crushed river stone to produce concrete. Slump test was conducted to evaluate the workability of fresh concrete and also compressive strength with stress-strain relationship was carried out to evaluate the hardened concrete that cured with two curing condition (e.g. sea water curing, and tap water-wet burlap curing). Test result indicated that fresh concrete had proper workability and all hardened specimens appeared a good compaction result. Compressive strength of specimens cured which sea water was higher than the specimens which cured by tap water-wet burlap where stress-strain behavior of specimens made with sea water, marine sand, and PCC had similar behavior with specimens which made with PCC and tap water.
Dolar, Davor; Vuković, Ana; Asperger, Danijela; Kosutić, Kresimir
2011-01-01
This study explored the removal of five veterinary pharmaceuticals (VPs) (sulfamethoxazole (SMETOX), trimethoprim (TMP), ciprofloxacin (CIPRO), dexamethasone (DEXA) and febantel (FEBA)) from different water matrices (Milli-Q water, model water, tap water and real pharmaceutical wastewater using four types of nanofiltration (NF) membranes (NF90, NF270, NF and HL) and two reverse osmosis (RO) membranes (LFC-1 and XLE). All VPs were added to different water matrices at a concentration of 10 mg/L. Rejections of VPs and water flux were measured. The rejection increased with increase of molecular weight. The highest rejections were obtained with RO membranes (LFC-1, XLE) and tight NF (NF90) membrane. In general, the rejection of VPs was higher in model water and tap water than in Milli-Q water, but the water flux was lower. This was mainly explained by ion adsorption inside the membranes pores. Narrower pore size counteracted the effect of presence of low concentration of natural organic matter (NOM) in tap water. The NOM was assumed to enhance the adsorption of VPs onto membrane surface, increased the size exclusion and electrostatic repulsion also appeared during the transport. Investigated water matrices had influence on water flux decline due to their complexity.
Comammox in drinking water systems.
Wang, Yulin; Ma, Liping; Mao, Yanping; Jiang, Xiaotao; Xia, Yu; Yu, Ke; Li, Bing; Zhang, Tong
2017-06-01
The discovery of complete ammonia oxidizer (comammox) has fundamentally upended our perception of the global nitrogen cycle. Here, we reported four metagenome assembled genomes (MAGs) of comammox Nitrospira that were retrieved from metagenome datasets of tap water in Singapore (SG-bin1 and SG-bin2), Hainan province, China (HN-bin3) and Stanford, CA, USA (ST-bin4). Genes of phylogenetically distinct ammonia monooxygenase subunit A (amoA) and hydroxylamine dehydrogenase (hao) were identified in these four MAGs. Phylogenetic analysis based on ribosomal proteins, AmoA, hao and nitrite oxidoreductase (subunits nxrA and nxrB) sequences indicated their close relationships with published comammox Nitrospira. Canonical ammonia-oxidizing microbes (AOM) were also identified in the three tap water samples, ammonia-oxidizing bacteria (AOB) in Singapore's and Stanford's samples and ammonia-oxidizing archaea (AOA) in Hainan's sample. The comammox amoA-like sequences were also detected from some other drinking water systems, and even outnumbered the AOA and AOB amoA-like sequences. The findings of MAGs and the occurrences of AOM in different drinking water systems provided a significant clue that comammox are widely distributed in drinking water systems. Copyright © 2017 Elsevier Ltd. All rights reserved.
Modeling lead concentration in drinking water of residential plumbing pipes and hot water tanks.
Chowdhury, Shakhawat; Kabir, Fayzul; Mazumder, Mohammad Abu Jafar; Zahir, Md Hasan
2018-09-01
Drinking water is a potential source of exposure to lead (Pb), which can pose risk to humans. The regulatory agencies often monitor Pb in water treatment plants (WTP) and/or water distribution systems (WDS). However, people are exposed to tap water inside the house while water may stay in the plumbing premise for several hours prior to reaching the tap. Depending on stagnation period and plumbing premise, concentrations of Pb in tap water can be significantly higher than the WDS leading to higher intake of Pb than the values from WDS or WTP. In this study, concentrations of Pb and water quality parameters were investigated in WDS, plumbing pipe (PP) and hot water tanks (HWT) for 7months. The samples were collected and analyzed on bi-weekly basis for 7 times a day. Several linear, non-linear and neural network models were developed for predicting Pb in PP and HWT. The models were validated using the additional data, which were not used for model development. The concentrations of Pb in PP and HWT were 1-1.17 and 1-1.21 times the Pb in WDS respectively. Concentrations of Pb were higher in summer than winter. The models showed moderate to excellent performance (R 2 =0.85-0.99) in predicting Pb in PP and HWT. The correlation coefficients (r) with the validation data were in the ranges of 0.76-0.90 and 0.97-0.99 for PP and HWT respectively. The models can be used for predicting Pb in tap water, which can assist to better protect the humans. Copyright © 2018. Published by Elsevier B.V.
Phylogenetic Diversity Analysis of Subterranean Hot Springs in Iceland
Marteinsson, Viggó Thór; Hauksdóttir, Sigurbjörg; Hobel, Cédric F. V.; Kristmannsdóttir, Hrefna; Hreggvidsson, Gudmundur Oli; Kristjánsson, Jakob K.
2001-01-01
Geothermal energy has been harnessed and used for domestic heating in Iceland. In wells that are typically drilled to a depth of 1,500 to 2,000 m, the temperature of the source water is 50 to 130°C. The bottoms of the boreholes can therefore be regarded as subterranean hot springs and provide a unique opportunity to study the subterranean biosphere. Large volumes of geothermal fluid from five wells and a mixture of geothermal water from 50 geothermal wells (hot tap water) were sampled and concentrated through a 0.2-μm-pore-size filter. Cells were observed in wells RG-39 (91.4°C) and MG-18 (71.8°C) and in hot tap water (76°C), but no cells were detected in wells SN-4, SN-5 (95 to 117°C), and RV-5 (130°C). Archaea and Bacteria were detected by whole-cell fluorescent in situ hybridization. DNAs were extracted from the biomass, and small-subunit rRNA genes (16S rDNAs) were amplified by PCR using primers specific for the Archaea and Bacteria domains. The PCR products were cloned and sequenced. The sequence analysis showed 11 new operational taxonomic units (OTUs) out of 14, 3 of which were affiliated with known surface OTUs. Samples from RG-39 and hot tap water were inoculated into enrichment media and incubated at 65 and 85°C. Growth was observed only in media based on geothermal water. 16S rDNA analysis showed enrichments dominated with Desulfurococcales relatives. Two strains belonging to Desulfurococcus mobilis and to the Thermus/Deinococcus group were isolated from borehole RG-39. The results indicate that subsurface volcanic zones are an environment that provides a rich subsurface for novel thermophiles. PMID:11526029
Phylogenetic diversity analysis of subterranean hot springs in Iceland.
Marteinsson, V T; Hauksdóttir, S; Hobel, C F; Kristmannsdóttir, H; Hreggvidsson, G O; Kristjánsson, J K
2001-09-01
Geothermal energy has been harnessed and used for domestic heating in Iceland. In wells that are typically drilled to a depth of 1,500 to 2,000 m, the temperature of the source water is 50 to 130 degrees C. The bottoms of the boreholes can therefore be regarded as subterranean hot springs and provide a unique opportunity to study the subterranean biosphere. Large volumes of geothermal fluid from five wells and a mixture of geothermal water from 50 geothermal wells (hot tap water) were sampled and concentrated through a 0.2-microm-pore-size filter. Cells were observed in wells RG-39 (91.4 degrees C) and MG-18 (71.8 degrees C) and in hot tap water (76 degrees C), but no cells were detected in wells SN-4, SN-5 (95 to 117 degrees C), and RV-5 (130 degrees C). Archaea and Bacteria were detected by whole-cell fluorescent in situ hybridization. DNAs were extracted from the biomass, and small-subunit rRNA genes (16S rDNAs) were amplified by PCR using primers specific for the Archaea and Bacteria domains. The PCR products were cloned and sequenced. The sequence analysis showed 11 new operational taxonomic units (OTUs) out of 14, 3 of which were affiliated with known surface OTUs. Samples from RG-39 and hot tap water were inoculated into enrichment media and incubated at 65 and 85 degrees C. Growth was observed only in media based on geothermal water. 16S rDNA analysis showed enrichments dominated with Desulfurococcales relatives. Two strains belonging to Desulfurococcus mobilis and to the Thermus/Deinococcus group were isolated from borehole RG-39. The results indicate that subsurface volcanic zones are an environment that provides a rich subsurface for novel thermophiles.
Lee, Yoonjin
2013-01-01
The predominant microorganisms in samples taken from shower heads in residences in the Korean city “N” were Stenotrophomonas maltophilia, Sphingomonas paucimobilis, Acidovorax temperans, and Microbacterium lacticum. Legionella was not detected in this case. The volatile organic compounds (VOCs) vinylacetate, NN-DMA, cis-1,2-dichloroethylene, epichlorohydrin, and styrene were measured in five types of plastic pipes: PVC, PB, PP, PE, and cPVC. The rate of multiplication of the heterotrophic plate count (HPC) attached on the copper pipe in contact with hot tap water was higher than the rate for the copper pipe in contact with cold tap water. Biofilm accumulation on stainless steel pipes with added acetate (3 mg/L) was 2.56 times higher than the non-supplemented condition. Therefore, the growth of HPC in the pipe system was affected by the type and availability of nutrients and depended on variables such as heating during the hot water supply. PMID:24018837
Lee, Yoonjin
2013-09-06
The predominant microorganisms in samples taken from shower heads in residences in the Korean city "N" were Stenotrophomonas maltophilia, Sphingomonas paucimobilis, Acidovorax temperans, and Microbacterium lacticum. Legionella was not detected in this case. The volatile organic compounds (VOCs) vinylacetate, NN-DMA, cis-1,2-dichloroethylene, epichlorohydrin, and styrene were measured in five types of plastic pipes: PVC, PB, PP, PE, and cPVC. The rate of multiplication of the heterotrophic plate count (HPC) attached on the copper pipe in contact with hot tap water was higher than the rate for the copper pipe in contact with cold tap water. Biofilm accumulation on stainless steel pipes with added acetate (3 mg/L) was 2.56 times higher than the non-supplemented condition. Therefore, the growth of HPC in the pipe system was affected by the type and availability of nutrients and depended on variables such as heating during the hot water supply.
The 2007 water crisis in Wuxi, China: analysis of the origin.
Zhang, Xiao-jian; Chen, Chao; Ding, Jian-qing; Hou, Aixin; Li, Yong; Niu, Zhang-bin; Su, Xiao-yan; Xu, Yan-juan; Laws, Edward A
2010-10-15
An odorous tap water crisis that affected two million residents for several days occurred in Wuxi, China in the summer of 2007. Volatile sulfide chemicals including methyl thiols, dimethyl sulfide, dimethyl disulfide, and dimethyl trisulfide were the dominant odorous contaminants in Lake Taihu and in tap water during the crisis. These contaminants originated from the decomposition of a massive cyanobacterial bloom that was triggered by illegal industrial discharges and inadequately regulated domestic pollution. A specific emergency drinking water treatment process was quickly developed using a combination of potassium permanganate oxidation and powdered activated carbon adsorption. The emergency treatment process removed the odor from the tap water and solved the crisis successfully in several days. This experience underscores the suggestion that a combination of stresses associated with eutrophication and industrial and domestic wastewater discharges can push an aquatic system to the tipping point with consequences far more severe than would occur if the system were subjected to each stress separately. 2010 Elsevier B.V. All rights reserved.
Mineral water or tap water? An endless debate.
De Giglio, O; Quaranta, A; Lovero, G; Caggiano, G; Montagna, M T
2015-01-01
The consumption of mineral water has been increasing because of the frequent and unjustified reports of the water supply contamination. However some authors have shown that bottled waters are not always better than tap water. Mineral waters are more palatable for organoleptic characteristic because, being pure at source, they do not undergo disinfection treatments and are sometimes enriched with CO2. In fact, they are characterized by their microbial facies subject to changes during the production cycle which can contribute to their contamination. It is necessary to provide people with the tools necessary to operate a critical choice of the type of water to be consumed not exclusively for their organoleptic characteristics or marketing strategies.
Magliano, Ana C M; da Silva, Flávia Maia; Teixeira, Marta M G; Alfieri, Silvia C
2009-11-01
Acanthamoeba spp., known to cause keratitis and granulomatous encephalitis in humans, are frequently isolated from a variety of water sources. Here we report for the first time the characterization of an Acanthamoeba sp. (ACC01) isolated from tap water in Brazil. This organism is currently being maintained in an axenic growth medium. Phylogenetic analysis based on SSU rRNA gene sequences positioned the new isolate in genotype T4, closest to the keratitis-causing isolate, A. polyphaga ATCC 30461 ( approximately 99% similarity). Acanthamoeba ACC01 and A. polyphaga 30461 both grew at 37 degrees C and were osmotically resistant, multiplying in hyperosmolar medium. Both isolates secreted comparable amounts of proteolytic enzymes, including serine peptidases that were optimally active at a near neutral/alkaline pH and resolved identically in gelatin gels. Incubation of gels at pH 4.0 with 2mM DTT also indicated the secretion of similar cysteine peptidases. Altogether, the results point to the pathogenic potential of Acanthamoeba ACC01.
TETRAVALENT LEAD: A HITHERTO UNRECOGNIZED CONTROL OF TAP WATER LEAD CONTAMINATION
Almost all of the theoretical framework underlying the control of plumbosolvency and lead release has been based on the presumption that the lead release is explicable by Pb(II) solubility, aqueous speciation, and reaction kinetics. Utilities struggling to comply with the Lead an...
Orr, T Edward; Whitford-Stoddard, Jennifer L; Elkins, Ralph L
2004-05-01
Taste-aversion (TA)-prone (TAP) rats and TA-resistant (TAR) rats have been developed by means of bidirectional selective breeding on the basis of their behavioral responses to a TA conditioning paradigm. The TA conditioning involved the pairing of an emetic-class agent (cyclophosphamide) with a novel saccharin solution as the conditioned stimulus. Despite the absence of ethanol in the selective breeding process, these rat lines differ widely in ethanol self-administration. In the current study, blood alcohol concentrations (BACs) were determined after 9 days of limited (2 h per day) access to a simultaneous, two-bottle choice of a 10% ethanol in water solution [volume/volume (vol./vol.)] or plain water. The BACs correlated highly with ethanol intake among TAR rats, but an insufficient number of TAP rats yielded measurable BACs to make the same comparison within this rat line. The same rats were subsequently exposed to 24-h access of a two-bottle choice (10% ethanol or plain water) for 8 days. Ethanol consumption during the 24-h access period correlated highly with that seen during limited access. Subsequent TA conditioning with these rats yielded line-typical differences in saccharin preferences. In a separate group of rats, ethanol clearance was determined by measuring BACs at 1, 4, and 7 h after injection of a 2.5-g/kg dose of ethanol. Ethanol clearance was not different between the two lines. Furthermore, the lines did not differ with respect to food and water consumption. Therefore, the TAP rat-TAR rat differences in ethanol consumption cannot be attributed to line differences in ethanol metabolism or in general consummatory behavior. The findings support our contention that the line differences in ethanol consumption are mediated by differences in TA-related mechanisms. The findings are discussed with respect to genetically based differences in the subjective experience of ethanol.
Borges, Sivanildo S.; Reis, Boaventura F.
2011-01-01
A photometric procedure for the determination of ClO− in tap water employing a miniaturized multicommuted flow analysis setup and an LED-based photometer is described. The analytical procedure was implemented using leucocrystal violet (LCV; 4,4′,4′′-methylidynetris (N,N-dimethylaniline), C25H31N3) as a chromogenic reagent. Solenoid micropumps employed for solutions propelling were assembled together with the photometer in order to compose a compact unit of small dimensions. After control variables optimization, the system was applied for the determination of ClO− in samples of tap water, and aiming accuracy assessment samples were also analyzed using an independent method. Applying the paired t-test between results obtained using both methods, no significant difference at the 95% confidence level was observed. Other useful features include low reagent consumption, 2.4 μg of LCV per determination, a linear response ranging from 0.02 up to 2.0 mg L−1 ClO−, a relative standard deviation of 1.0% (n = 11) for samples containing 0.2 mg L−1 ClO−, a detection limit of 6.0 μg L−1 ClO−, a sampling throughput of 84 determinations per hour, and a waste generation of 432 μL per determination. PMID:21747732
NASA Astrophysics Data System (ADS)
Riduan Jamalludin, Mohd; Harun, Zawati; Khadijah Hubadillah, Siti; Hafiz Dzarfan Othman, Mohd; Hasliza Kamarudin, Noor; Zaini Yunos, Muhamad; Izzati Ismail, Ras; Lailina, N. M.
2018-03-01
The addition of polyethylene glycol (PEG), graphene oxide (GO) and triaminopyrimidine (TAP) into polysulfone membranes was used to modify the membrane morphology and increase membrane performance. The central composite design of the response surface methodology was used to predict the maximum permeability and rejection of the PSf membrane. The parameter chosen for this study were PEG (7-14 wt%), GO (0-2.5wt%) and TAP (0-0.5 wt%) concentration. The flat sheet membrane was prepared via phase inversion technique where polysulfone (PSf) was used as base polymer. Various concentration of GO, PEG and TAP were added into the casting solution to produce different membrane composition. PEG was added as pore forming agent for the PSf membrane while inorganic additive such as GO was used to increase the hydrophilicity of the membrane. Besides that, the addition of TAP as a compatibilizer to enhance the physical interaction between GO and PEG. The characterization and surface morphology of produced membrane were analysed via scanning electron microscope, SEM and X-ray diffraction, XRD. The optimization of membrane performance was carried out by using response surface methodology (RSM). The performance of the membrane was analysed by using distilled water for pure water flux test and humic acid for rejection test. The optimized responses, membrane permeability and rejection obtained experimentally were 301.562 Lm-2h-1 and 91.562% respectively, with deviation from the predicted value of 7.884 and 0.4381 %, respectively.
The purpose of this SOP is to describe the collection, storage, and shipment of tap and drinking water samples for analysis by EPA method 524.2 (revision 4.0) for the NHEXAS Arizona project. This SOP provides a brief description of the sample containers, collection, preservation...
Loh, Miranda M.; Sugeng, Anastasia; Lothrop, Nathan; Klimecki, Walter; Cox, Melissa; Wilkinson, Sarah T.; Lu, Zhenqiang; Beamer, Paloma I.
2016-01-01
Children living near contaminated mining waste areas may have high exposures to metals from the environment. This study investigates whether exposure to arsenic and lead is higher in children in a community near a legacy mine and smelter site in Arizona compared to children in other parts of the United States and the relationship of that exposure to the site. Arsenic and lead were measured in residential soil, house dust, tap water, urine, and toenail samples from 70 children in 34 households up to 7 miles from the site. Soil and house dust were sieved, digested, and analyzed via ICP-MS. Tap water and urine were analyzed without digestion, while toenails were washed, digested and analyzed. Blood lead was analyzed by an independent, certified laboratory. Spearman correlation coefficients were calculated between each environmental media and urine and toenails for arsenic and lead. Geometric mean arsenic (standard deviation) concentrations for each matrix were: 22.1 (2.59) ppm and 12.4 (2.27) ppm for soil and house dust (<63 μm), 5.71 (6.55) ppb for tap water, 14.0 (2.01) μg/L for specific gravity-corrected total urinary arsenic, 0.543 (3.22) ppm for toenails. Soil and vacuumed dust lead concentrations were 16.9 (2.03) ppm and 21.6 (1.90) ppm. The majority of blood lead levels were below the limit of quantification. Arsenic and lead concentrations in soil and house dust decreased with distance from the site. Concentrations in soil, house dust, tap water, along with floor dust loading were significantly associated with toenail and urinary arsenic but not lead. Mixed models showed that soil and tap water best predicted urinary arsenic. In our study, despite being present in mine tailings at similar levels, internal lead exposure was not high, but arsenic exposure was of concern, particularly from soil and tap water. Naturally occurring sources may be an additional important contributor to exposures in certain legacy mining areas. PMID:26803211
Preference for tap, bottled, and recycled water: Relations to PTC taste sensitivity and personality.
Harmon, Daniel; Gauvain, Mary; Z Reisz; Arthur, Isaac; Story, S Drew
2018-02-01
This study investigated people's preferences for different water sources and factors that predict such preferences using a blind taste test. Water preferences of 143 participants for one name-brand bottled water, one groundwater-sourced tap water, and one indirect potable reuse (IDR) water were assessed. For predictors of water preference, we measured each participant's PTC taste sensitivity and assessed two personality traits (Neuroticism, Openness to Experience). We also explored participants' descriptions of each water source. Results indicate a preference for water treated with Reverse Osmosis (RO) (bottled and IDR water) over groundwater-sourced water, which had higher pH levels and lower concentrations of Ca and HCO 3 - . PTC taste sensitivity did not predict preferences, while Openness to Experience and Neuroticism predicted preference for IDR water. Positive relations between Openness to Experience and preferences for bottled and IDR water were moderated by gender and were stronger among females. Participants described water primarily by its taste and texture. Findings suggest that (1) tap water treated by RO is equally preferable to some bottled water, (2) personality traits may affect water preferences, and (3) prior findings of gender differences in preferences for bottled water may reflect personality characteristics. Efforts to increase acceptance for sustainable water alternatives, such as IDR, may be more successful by assuring consumers about taste and addressing personality traits that encourage or inhibit use. Copyright © 2017 Elsevier Ltd. All rights reserved.
Iyo, Toru; Asakura, Keiko; Nakano, Makiko; Yamada, Mutsuko; Omae, Kazuyuki
2016-02-01
Despite the reported health-related advantages of the use of warm water in bidets, there are health-related disadvantages associated with the use of these toilet seats, and the bacterial research is sparse. We conducted a survey on the hygienic conditions of 127 warm-water bidet toilet seats in restrooms on a university campus. The spray water from the toilet seats had less residual chlorine than their tap water sources. However, the total viable microbial count was below the water-quality standard for tap water. In addition, the heat of the toilet seats' warm-water tanks caused heterotrophic bacteria in the source tap water to proliferate inside the nozzle pipes and the warm-water tanks. Escherichia coli was detected on the spray nozzles of about 5% of the toilet seats, indicating that the self-cleaning mechanism of the spray nozzles was largely functioning properly. However, Pseudomonas aeruginosa was detected on about 2% of the toilet seats. P. aeruginosa was found to remain for long durations in biofilms that formed inside warm-water tanks. Infection-prevention measures aimed at P. aeruginosa should receive full consideration when managing warm-water bidet toilet seats in hospitals in order to prevent opportunistic infections in intensive care units, hematology wards, and other hospital locations.
Casanova, Lisa M; Walters, Adam; Naghawatte, Ajith; Sobsey, Mark D
2012-06-01
Sri Lanka was devastated by the 2004 Indian Ocean tsunami. During recovery, the Red Cross distributed approximately 12,000 free ceramic water filters. This cross-sectional study was an independent post-implementation assessment of 452 households that received filters, to determine the proportion still using filters, household characteristics associated with use, and quality of household drinking water. The proportion of continued users was high (76%). The most common household water sources were taps or shallow wells. The majority (82%) of users used filtered water for drinking only. Mean filter flow rate was 1.12 L/hr (0.80 L/hr for households with taps and 0.71 for those with wells). Water quality varied by source; households using tap water had source water of high microbial quality. Filters improved water quality, reducing Escherichia coli for households (largely well users) with high levels in their source water. Households were satisfied with filters and are potentially long-term users. To promote sustained use, recovery filter distribution efforts should try to identify households at greatest long-term risk, particularly those who have not moved to safer water sources during recovery. They should be joined with long-term commitment to building supply chains and local production capacity to ensure safe water access.
Ahmed, W; Hodgers, L; Sidhu, J P S; Toze, S
2012-01-01
In this study, the microbiological quality of household tap water samples fed from rainwater tanks was assessed by monitoring the numbers of Escherichia coli bacteria and enterococci from 24 households in Southeast Queensland (SEQ), Australia. Quantitative PCR (qPCR) was also used for the quantitative detection of zoonotic pathogens in water samples from rainwater tanks and connected household taps. The numbers of zoonotic pathogens were also estimated in fecal samples from possums and various species of birds by using qPCR, as possums and birds are considered to be the potential sources of fecal contamination in roof-harvested rainwater (RHRW). Among the 24 households, 63% of rainwater tank and 58% of connected household tap water (CHTW) samples contained E. coli and exceeded Australian drinking water guidelines of <1 CFU E. coli per 100 ml water. Similarly, 92% of rainwater tanks and 83% of CHTW samples also contained enterococci. In all, 21%, 4%, and 13% of rainwater tank samples contained Campylobacter spp., Salmonella spp., and Giardia lamblia, respectively. Similarly, 21% of rainwater tank and 13% of CHTW samples contained Campylobacter spp. and G. lamblia, respectively. The number of E. coli (P = 0.78), Enterococcus (P = 0.64), Campylobacter (P = 0.44), and G. lamblia (P = 0.50) cells in rainwater tanks did not differ significantly from the numbers observed in the CHTW samples. Among the 40 possum fecal samples tested, Campylobacter spp., Cryptosporidium parvum, and G. lamblia were detected in 60%, 13%, and 30% of samples, respectively. Among the 38 bird fecal samples tested, Campylobacter spp., Salmonella spp., C. parvum, and G. lamblia were detected in 24%, 11%, 5%, and 13% of the samples, respectively. Household tap water samples fed from rainwater tanks tested in the study appeared to be highly variable. Regular cleaning of roofs and gutters, along with pruning of overhanging tree branches, might also prove effective in reducing animal fecal contamination of rainwater tanks.
Hodgers, L.; Sidhu, J. P. S.; Toze, S.
2012-01-01
In this study, the microbiological quality of household tap water samples fed from rainwater tanks was assessed by monitoring the numbers of Escherichia coli bacteria and enterococci from 24 households in Southeast Queensland (SEQ), Australia. Quantitative PCR (qPCR) was also used for the quantitative detection of zoonotic pathogens in water samples from rainwater tanks and connected household taps. The numbers of zoonotic pathogens were also estimated in fecal samples from possums and various species of birds by using qPCR, as possums and birds are considered to be the potential sources of fecal contamination in roof-harvested rainwater (RHRW). Among the 24 households, 63% of rainwater tank and 58% of connected household tap water (CHTW) samples contained E. coli and exceeded Australian drinking water guidelines of <1 CFU E. coli per 100 ml water. Similarly, 92% of rainwater tanks and 83% of CHTW samples also contained enterococci. In all, 21%, 4%, and 13% of rainwater tank samples contained Campylobacter spp., Salmonella spp., and Giardia lamblia, respectively. Similarly, 21% of rainwater tank and 13% of CHTW samples contained Campylobacter spp. and G. lamblia, respectively. The number of E. coli (P = 0.78), Enterococcus (P = 0.64), Campylobacter (P = 0.44), and G. lamblia (P = 0.50) cells in rainwater tanks did not differ significantly from the numbers observed in the CHTW samples. Among the 40 possum fecal samples tested, Campylobacter spp., Cryptosporidium parvum, and G. lamblia were detected in 60%, 13%, and 30% of samples, respectively. Among the 38 bird fecal samples tested, Campylobacter spp., Salmonella spp., C. parvum, and G. lamblia were detected in 24%, 11%, 5%, and 13% of the samples, respectively. Household tap water samples fed from rainwater tanks tested in the study appeared to be highly variable. Regular cleaning of roofs and gutters, along with pruning of overhanging tree branches, might also prove effective in reducing animal fecal contamination of rainwater tanks. PMID:22020514
Buffer substitution in malaria rapid diagnostic tests causes false-positive results
2010-01-01
Background Malaria rapid diagnostic tests (RDTs) are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution) or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results. Methods Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and Plasmodium positive samples. Results Only eight cassettes (in four RDT brands) showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74%) RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20), and in 15 RDTs which were run with distilled water only. They occurred for all Plasmodium antigens and RDT formats (two-, three- and four-band RDTs). Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness) of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and Plasmodium positive samples. Conclusion Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results. PMID:20650003
Bi-Xian, N I; Ming-Xue, S; Xiang-Zhen, X U; Xiao-Ting, W; Yang, D; Xiao-Lin, J
2017-05-17
Objective To know the contamination status of Giardia lamblia and Cryptosporidium in drinking water of Jiangsu Province, so as to provide the evidence for producing hygiene and safety drinking water. Methods A total of 28 water plants of 13 cities in Jiangsu Province were selected, and the source water (10 L), chlorinated water (100 L) and tap water (100 L) were collected separately in each site. The water samples were then treated by filtration, washing, centrifuging concentration, immune magnetic separation, and immunofluorescent assay, to detect the numbers of Giardia cysts and Cryptosporidium oocysts. Results Totally 84 samples from 13 cities were collected, including 28 source water, 28 chlorinated water and 28 tap water samples. Among the chlorinated water and tap water samples, no Giardia cysts and Cryptosporidium oocysts were found. However, Giardia cysts were detected in 3 (10.71%, 3/28) source water samples (Yancheng, Lianyungang, Changzhou cities), with the density of 1 cyst/10 L of all. Cryptosporidium oocysts were also detected in 3 (10.71%, 3/28) source water samples (Nanjing, Zhenjiang, Yangzhou cities), with the density of 1 oocyst/10 L of all. Conclusions The source water in partial areas of Jiangsu Province has been contaminated by Giardia and Cryptosporidium . To ensure the safety of drinking, the regulation of source water and surveillance of drinking water should be strengthened.
Shlosberg, A; Bellaiche, M; Berman, E; Ben David, A; Deeb, N; Cahaner, A
1998-09-01
A hypothesis that the ionic composition of drinking water might affect development of the ascites syndrome in broilers was investigated in two trials. The first trial comprised four groups of 650 male chicks. A control treatment was normal tap water and the other three treatments comprised the addition to the tap water of 1,000 mg/L sodium as NaCl, 5,000 mg/L NH4Cl, or 5,000 mg/L KHCO3, supplied from age 2 to 47 d. At Day 28, equally sized subsets of these groups were moved to individual cages, where they received a severe exposure to ambient cold. The development of the ascites syndrome was monitored by measurements of hematocrit and arterial blood oxygen saturation (PaO2) by oximetry, body weight, and examination of dead birds for cause of death. Mortality from ascites in cold-exposed birds from Days 28 to 47 was 28, 48, 40, and 16% in the tap water, NaCl, NH4Cl, and KHCO3 groups, respectively; only the NaCl mortality was significantly different from the tap water mortality. The KHCO3 treatment increased PaO2 (compared with tap water treatment) at Day 28 by 5.5% and at Day 35 by 10.5%, but not at Day 42. The KHCO3 caused a reduction in body weight, which was 13% less than the tap water group at Day 42, probably due to a chronic toxicity. The second trial specifically examined the same parameters with lower water levels of KHCO3 (3,000 and 1,000 mg/L), in comparison to a 10% feed restriction protocol, in order to clarify whether the increased PaO2 was due to a specific effect of the KHCO3 or was a metabolic manifestation of a reduced growth rate. The 3,000 mg/L KHCO3 treatment had no effect on PaO2, but the 1,000 mg/L treatment augmented PaO2 by 5.3% at Day 35 (but not at Days 28 or 42), without reducing the final body weight. The feed restriction group showed an elevated PaO2 of 5.4% at Day 35 (but not at Days 28 or 42), with no reduction in the final body weight. The inclusion of 1,000 mg/L of KHCO3 into the drinking water of broilers or a temporary 10% feed restriction may be means to augment PaO2.
Villar-Navarro, Mercedes; Martín-Valero, María Jesús; Fernández-Torres, Rut Maria; Callejón-Mochón, Manuel; Bello-López, Miguel Ángel
2017-02-15
An easy and environmental friendly method, based on the use of magnetic molecular imprinted polymers (mag-MIPs) is proposed for the simultaneous extraction of the 16 U.S. EPA polycyclic aromatic hydrocarbons (PAHs) priority pollutants. The mag-MIPs based extraction protocol is simple, more sensitive and low organic solvent consuming compared to official methods and also adequate for those PAHs more retained in the particulate matter. The new proposed extraction method followed by HPLC determination has been validated and applied to different types of water samples: tap water, river water, lake water and mineral water. Copyright © 2017 Elsevier B.V. All rights reserved.
Jeandron, Aurélie; Saidi, Jaime Mufitini; Kapama, Alois; Burhole, Manu; Birembano, Freddy; Vandevelde, Thierry; Gasparrini, Antonio; Armstrong, Ben; Cairncross, Sandy; Ensink, Jeroen H J
2015-10-01
The eastern provinces of the Democratic Republic of the Congo have been identified as endemic areas for cholera transmission, and despite continuous control efforts, they continue to experience regular cholera outbreaks that occasionally spread to the rest of the country. In a region where access to improved water sources is particularly poor, the question of which improvements in water access should be prioritized to address cholera transmission remains unresolved. This study aimed at investigating the temporal association between water supply interruptions and Cholera Treatment Centre (CTC) admissions in a medium-sized town. Time-series patterns of daily incidence of suspected cholera cases admitted to the Cholera Treatment Centre in Uvira in South Kivu Province between 2009 and 2014 were examined in relation to the daily variations in volume of water supplied by the town water treatment plant. Quasi-poisson regression and distributed lag nonlinear models up to 12 d were used, adjusting for daily precipitation rates, day of the week, and seasonal variations. A total of 5,745 patients over 5 y of age with acute watery diarrhoea symptoms were admitted to the CTC over the study period of 1,946 d. Following a day without tap water supply, the suspected cholera incidence rate increased on average by 155% over the next 12 d, corresponding to a rate ratio of 2.55 (95% CI: 1.54-4.24), compared to the incidence experienced after a day with optimal production (defined as the 95th percentile-4,794 m3). Suspected cholera cases attributable to a suboptimal tap water supply reached 23.2% of total admissions (95% CI 11.4%-33.2%). Although generally reporting less admissions to the CTC, neighbourhoods with a higher consumption of tap water were more affected by water supply interruptions, with a rate ratio of 3.71 (95% CI: 1.91-7.20) and an attributable fraction of cases of 31.4% (95% CI: 17.3%-42.5%). The analysis did not suggest any association between levels of residual chlorine in the water fed to the distribution network and suspected cholera incidence. Laboratory confirmation of cholera was not available for this analysis. A clear association is observed between reduced availability of tap water and increased incidence of suspected cholera in the entire town of Uvira in Eastern Democratic Republic of the Congo. Even though access to piped water supplies is low in Uvira, improving the reliability of tap water supply may substantially reduce the incidence of suspected cholera, in particular in neighbourhoods having a higher access to tap water. These results argue in favour of water supply investments that focus on the delivery of a reliable and sustainable water supply, and not only on point-of-use water quality improvements, as is often seen during cholera outbreaks.
Jeandron, Aurélie; Saidi, Jaime Mufitini; Kapama, Alois; Burhole, Manu; Birembano, Freddy; Vandevelde, Thierry; Gasparrini, Antonio; Armstrong, Ben; Cairncross, Sandy; Ensink, Jeroen H. J.
2015-01-01
Background The eastern provinces of the Democratic Republic of the Congo have been identified as endemic areas for cholera transmission, and despite continuous control efforts, they continue to experience regular cholera outbreaks that occasionally spread to the rest of the country. In a region where access to improved water sources is particularly poor, the question of which improvements in water access should be prioritized to address cholera transmission remains unresolved. This study aimed at investigating the temporal association between water supply interruptions and Cholera Treatment Centre (CTC) admissions in a medium-sized town. Methods and Findings Time-series patterns of daily incidence of suspected cholera cases admitted to the Cholera Treatment Centre in Uvira in South Kivu Province between 2009 and 2014 were examined in relation to the daily variations in volume of water supplied by the town water treatment plant. Quasi-poisson regression and distributed lag nonlinear models up to 12 d were used, adjusting for daily precipitation rates, day of the week, and seasonal variations. A total of 5,745 patients over 5 y of age with acute watery diarrhoea symptoms were admitted to the CTC over the study period of 1,946 d. Following a day without tap water supply, the suspected cholera incidence rate increased on average by 155% over the next 12 d, corresponding to a rate ratio of 2.55 (95% CI: 1.54–4.24), compared to the incidence experienced after a day with optimal production (defined as the 95th percentile—4,794 m3). Suspected cholera cases attributable to a suboptimal tap water supply reached 23.2% of total admissions (95% CI 11.4%–33.2%). Although generally reporting less admissions to the CTC, neighbourhoods with a higher consumption of tap water were more affected by water supply interruptions, with a rate ratio of 3.71 (95% CI: 1.91–7.20) and an attributable fraction of cases of 31.4% (95% CI: 17.3%–42.5%). The analysis did not suggest any association between levels of residual chlorine in the water fed to the distribution network and suspected cholera incidence. Laboratory confirmation of cholera was not available for this analysis. Conclusions A clear association is observed between reduced availability of tap water and increased incidence of suspected cholera in the entire town of Uvira in Eastern Democratic Republic of the Congo. Even though access to piped water supplies is low in Uvira, improving the reliability of tap water supply may substantially reduce the incidence of suspected cholera, in particular in neighbourhoods having a higher access to tap water. These results argue in favour of water supply investments that focus on the delivery of a reliable and sustainable water supply, and not only on point-of-use water quality improvements, as is often seen during cholera outbreaks. PMID:26506001
Water Safety and Lead Regulation: Physicians' Community Health Responsibilities.
Jennings, Bruce; Duncan, Leslie Lyons
2017-10-01
This article reviews the regulation of lead in drinking water, highlighting its epidemiological, engineering, and ethical aspects with a focus on the Flint water crisis. We first discuss water quality policy and its implementation with a focus on lead contamination of water, primarily from pipe systems between a water treatment facility and a tap. We then discuss physicians' roles and ethical responsibilities regarding safe drinking water using a human rights framework. We argue that physicians can play an important role in safeguarding drinking water in their communities by being vigilant, honoring the community's trust in them, and warning, educating, and empowering patients and broader communities so as to protect tap water safety and public health. © 2017 American Medical Association. All Rights Reserved.
Correlation between lead levels in drinking water and mothers' breast milk: Dakahlia, Egypt.
Mandour, Raafat A; Ghanem, Abdel-Aziz; El-Azab, Somaia M
2013-04-01
This study was performed on fifty-two drinking tap water samples (surface and groundwater) collected from different districts of Dakahlia Governorate and fifty-two breast milk samples from lactating mothers hosted in Dakahlia Governorate hospitals. All these samples were subjected to lead analysis. Lead level in drinking groundwater showed higher levels than in drinking surface water. Also, an elevation of lead levels in breast milk of mothers drinking groundwater was noticed when compared with that of mothers drinking surface water. The comparison between mean lead levels in drinking water and mothers' breast milk samples showed positive relationship. Lead concentrations in breast milk of the studied samples were elevated by exposure to smoking. We conclude that prolonged contact with lead plumbing can increase the lead content in tap water with subsequent increase in lead burden in infant fed formula and infant blood. Also, we recommend that chemical analyses must be carried out periodically for the surface and groundwater to ensure the water suitability for drinking purposes. Passive exposure to smoking during lactation should be avoided. Capsule: Prolonged contact with lead plumbing can increase the lead content in tap water with subsequent increase in lead burden in infant fed formula and infant blood.
Boger, Jennifer; Taati, Babak; Mihailidis, Alex
2016-10-01
The changes in cognitive abilities that accompany dementia can make it difficult to use everyday products that are required to complete activities of daily living. Products that are inherently more usable for people with dementia could facilitate independent activity completion, thus reducing the need for caregiver assistance. The objectives of this research were to: (1) gain an understanding of how water tap design impacted tap usability and (2) create an automated computerized tool that could assess tap usability. 27 older adults, who ranged from cognitively intact to advanced dementia, completed 1309 trials on five tap designs. Data were manually analyzed to investigate tap usability as well as used to develop an automated usability analysis tool. Researchers collaborated to modify existing techniques and to create novel ones to accomplish both goals. This paper presents lessons learned through the course of this research, which could be applicable in the development of other usability studies, automated vision-based assessments and the development of assistive technologies for cognitively impaired older adults. Collaborative interdisciplinary teamwork, which included older adult with dementia participants, was key to enabling innovative advances that achieved the projects' research goals. Implications for Rehabilitation Products that are implicitly familiar and usable by older adults could foster independent activity completion, potentially reducing reliance on a caregiver. The computer-based automated tool can significantly reduce the time and effort required to perform product usability analysis, making this type of analysis more feasible. Interdisciplinary collaboration can result in a more holistic understanding of assistive technology research challenges and enable innovative solutions.
Modifying a known gelator scaffold for nitrite detection.
Zurcher, Danielle M; Adhia, Yash J; Romero, Julián Díaz; McNeil, Anne J
2014-07-25
The process of selecting and modifying a known gelator scaffold to develop a new nitrite-based sensor is described. Five new azo-sulfonate gelators were discovered and characterized. The most promising scaffold exhibits a stable diazonium intermediate, proceeds in a high yield, and gels nitrite-spiked tap, river, and pond water.
Bogart, Laura M.; Cowgill, Burton O.; Elliott, Marc N.; Klein, David J.; Hawes-Dawson, Jennifer; Uyeda, Kimberly; Elijah, Jacinta; Binkle, David G.; Schuster, Mark A.
2014-01-01
Purpose To conduct a randomized controlled trial of Students for Nutrition and eXercise (SNaX), a 5-week middle-school-based obesity-prevention intervention combining school-wide environmental changes, multimedia, encouragement to eat healthy school cafeteria foods, and peer-led education. Methods We randomly selected schools (five intervention, five wait-list control) from the Los Angeles Unified School District. School records were obtained for number of fruits and vegetables served, students served lunch, and snacks sold per attending student, representing an average of 1,515 students (SD=323) per intervention school and 1,524 students (SD=266) per control school. A total of 2,997 seventh-graders (75% of seventh-graders across schools) completed pre-and post-intervention surveys assessing psychosocial variables. Consistent with community-based participatory research principles, the school district was an equal partner and a community advisory board provided critical input. Results Relative to control schools, intervention schools showed significant increases in the proportion of students served fruit and lunch and a significant decrease in proportion of students buying snacks at school. Specifically, the intervention was associated with relative increases of 15.3% more fruit served (p=0.006), 10.4% more lunches served (p<0.001), and 11.9% fewer snacks sold (p<0.001) than would have been expected in its absence. Pre-to-post intervention, intervention school students reported more positive attitudes about cafeteria food (p=0.02) and tap water (p=0.03), greater obesity-prevention knowledge (p=0.006), increased intentions to drink water from the tap (p=0.04) or a refillable bottle (p=0.02), and greater tap water consumption (p=0.04) compared to control school students. Conclusions Multi-level school-based interventions may promote healthy adolescent dietary behaviors. PMID:24784545
Hutchins, C F; Moore, G; Thompson, K-A; Webb, J; Walker, J T
2017-10-01
Pseudomonas aeruginosa infections have been linked to contaminated hospital taps, highlighting the potential for tap outlet fittings (OF) to harbour biofilm. P. aeruginosa may be transferred to OFs via contaminated cleaning cloths. Suggested interventions include flushing regimens and alternative OF designs. To investigate the transfer of P. aeruginosa from a contaminated cleaning cloth to conventional and 'antimicrobial/antibiofilm' OFs and to determine whether this contamination persists and/or leads to contamination of tap water. Microfibre cloths contaminated with P. aeruginosa (10 8 cfu/mL) were used to wipe four different types of OF [one of conventional design (OF-A) and three marketed as 'antimicrobial' and/or 'antibiofilm' (OF- B, -C and -D)]. OFs were inserted into an experimental water distribution system for up to 24 h. Survival was assessed by culture. Single and multiple water samples were collected and cultured for P. aeruginosa. The median number of P. aeruginosa transferred from cloth to OF was 5.7 × 10 5 cfu (OF-A), 1.9 × 10 6 cfu (OF-B), 1.4 × 10 5 cfu (OF-C) and 2.9 × 10 6 cfu (OF-D). Numbers declined on all OFs during the 24 h period with log reductions ranging from 3.5 (OF-C) to 5.2 (OF-B; P > 0.05). All water samples delivered immediately after OF contamination contained P. aeruginosa at ≥10 cfu per 100 mL. Contamination of water delivered from OF-A persisted despite continued flushing. Water delivered from OF-B did not contain P. aeruginosa beyond the first flush. Contaminated cleaning cloths may transfer P. aeruginosa to OFs, leading to contamination of tap water. Although not removing the potential for contamination, 'antimicrobial/antibiofilm' OFs may prevent P. aeruginosa from continually contaminating water delivered from the outlet. Copyright © 2017 The Healthcare Infection Society. All rights reserved.
Effect of aerosol particles generated by ultrasonic humidifiers on the lung in mouse.
Umezawa, Masakazu; Sekita, Keisuke; Suzuki, Ken-Ichiro; Kubo-Irie, Miyoko; Niki, Rikio; Ihara, Tomomi; Sugamata, Masao; Takeda, Ken
2013-12-21
Ultrasonic humidifiers silently generate water droplets as a cool fog and produce most of the dissolved minerals in the fog in the form of an aerosolized "white dust." However, the health effect of these airborne particles is largely unknown. This study aimed to characterize the aerosol particles generated by ultrasonic humidifiers and to investigate their effect on the lung tissue of mice. An ultrasonic humidifier was operated with tap water, high-silica water, ultrapure water, or other water types. In a chamber (0.765 m3, ventilation ratio 11.5 m3/hr), male ICR mice (10-week-old) were exposed by inhalation to an aerosol-containing vapor generated by the humidifier. After exposure for 7 or 14 days, lung tissues and bronchoalveolar lavage fluid (BALF) were collected from each mouse and examined by microarray, quantitative reverse transcription-polymerase chain reaction, and light and electron microscopy. Particles generated from the humidifier operated with tap water had a mass concentration of 0.46 ± 0.03 mg/m3, number concentration of (5.0 ± 1.1) × 10(4)/cm3, and peak size distribution of 183 nm. The particles were phagocytosed by alveolar macrophages in the lung of mice. Inhalation of particles caused dysregulation of genes related to mitosis, cell adhesion molecules, MHC molecules and endocytosis, but did not induce any signs of inflammation or tissue injury in the lung. These results indicate that aerosol particles released from ultrasonic humidifiers operated with tap water initiated a cellular response but did not cause severe acute inflammation in pulmonary tissue. Additionally, high mineral content tap water is not recommended and de-mineralized water should be recommended in order to exclude any adverse effects.
NASA Astrophysics Data System (ADS)
Agudelo-Vera, Claudia M.; Blokker, Mirjam; de Kater, Henk; Lafort, Rob
2017-09-01
The water temperature in the drinking water distribution system and at customers' taps approaches the surrounding soil temperature at a depth of 1 m. Water temperature is an important determinant of water quality. In the Netherlands drinking water is distributed without additional residual disinfectant and the temperature of drinking water at customers' taps is not allowed to exceed 25 °C. In recent decades, the urban (sub)surface has been getting more occupied by various types of infrastructures, and some of these can be heat sources. Only recently have the anthropogenic sources and their influence on the underground been studied on coarse spatial scales. Little is known about the urban shallow underground heat profile on small spatial scales, of the order of 10 m × 10 m. Routine water quality samples at the tap in urban areas have shown up locations - so-called hotspots - in the city, with relatively high soil temperatures - up to 7 °C warmer - compared to the soil temperatures in the surrounding rural areas. Yet the sources and the locations of these hotspots have not been identified. It is expected that with climate change during a warm summer the soil temperature in the hotspots can be above 25 °C. The objective of this paper is to find a method to identify heat sources and urban characteristics that locally influence the soil temperature. The proposed method combines mapping of urban anthropogenic heat sources, retrospective modelling of the soil temperature, analysis of water temperature measurements at the tap, and extensive soil temperature measurements. This approach provided insight into the typical range of the variation of the urban soil temperature, and it is a first step to identifying areas with potential underground heat stress towards thermal underground management in cities.
Armand, B; Motazedian, M H; Asgari, Q
2016-01-01
Free-living amoebae (FLA) are the most abundant and widely distributed protozoa in the environment. An investigation was conducted to determine the presence of free-living amoebae (FLA), Acanthamoeba and Vermamoeba in waterfronts of parks and squares and tap water of Shiraz City, Iran. FLA are considered pathogenic for human. These ubiquitous organisms have been isolated from different environments such as water, soil, and air. Eighty-two water samples were collected from different places of Shiraz City during the summer of 2013. All samples were processed in Dept. of Parasitology and Mycology, Shiraz University of Medical Sciences, Fars, Iran. Samples were screened for FLA and identified by morphological characters in the cultures, PCR amplification targeting specific genes for each genus and sequencing determined frequent species and genotypes base on NCBI database. Overall, 48 samples were positive for Acanthamoeba and Vermamoeba in non-nutrient agar culture based on morphological characteristics. The PCR examination was done successfully. Sequencing results were revealed T4 (62.96 %) genotypes as the most common genotype of Acanthamoeba in the Shiraz water sources. In addition, T5 (33.33 %) and T15 (3.71 %) were isolated from water supplies. Vermamoeba vermiformis was known the dominant species from this genus. The high frequency of Acanthamoeba spp. and Vermamoeba in different environmental water sources of Shiraz is an alert for the public health related to water sources. The result highlights a need for taking more attention to water supplies in order to prevent illnesses related to free-living amoebae.
The purpose of this SOP is to describe the collection, storage, and shipment of tap and drinking water samples for analysis by EPA method 524.2 (revision 4.0). This SOP provides a brief description of the sample containers, collection, preservation, storage, shipping, and custod...
The purpose of this SOP is to describe how to collect, store, and ship tap and drinking water samples for analysis by EPA Method 200.8 (revision 4.4) for the NHEXAS Arizona project. This SOP provides a brief description of the sample containers, collection, preservation, storage...
In vitro bioanalysis of drinking water from source to tap.
Rosenmai, Anna Kjerstine; Lundqvist, Johan; le Godec, Théo; Ohlsson, Åsa; Tröger, Rikard; Hellman, Björn; Oskarsson, Agneta
2018-08-01
The presence of chemical pollutants in sources of drinking water is a key environmental problem threatening public health. Efficient removal of pollutants in drinking water treatment plants (DWTPs) is needed as well as methods for assessment of the total impact of all present chemicals on water quality. In the present study we have analyzed the bioactivity of water samples from source to tap, including effects of various water treatments in a DWTP, using a battery of cell-based bioassays, covering health-relevant endpoints. Reporter gene assays were used to analyze receptor activity of the aryl hydrocarbon receptor (AhR), estrogen receptor (ER), androgen receptor (AR), peroxisome proliferator-activated receptor alpha (PPARα) and induction of oxidative stress by the nuclear factor erythroid 2-related factor 2 (Nrf2). DNA damage was determined by Comet assay. Grab water samples were concentrated by HLB or ENV solid phase extraction and the water samples assayed at a relative enrichment factor of 50. The enrichment procedure did not induce any bioactivity. No bioactivity was detected in Milli-Q water or drinking water control samples. Induction of AhR, ER and Nrf2 activities was revealed in source to tap water samples. No cytotoxicity, PPARα or AR antagonist activity, or DNA damage were observed in any of the water samples. A low AR agonist activity was detected in a few samples of surface water, but not in the samples from the DWTP. The treatment steps at the DWTP, coagulation, granulated activated carbon filtration, UV disinfection and NH 2 Cl dosing had little or no effect on the AhR, Nrf2 and ER bioactivity. However, nanofiltration and passage through the distribution network drastically decreased AhR activity, while the effect on Nrf2 activity was more modest and no apparent effect was observed on ER activity. The present results suggest that bioassays are useful tools for evaluation of the efficiency of different treatment steps in DWTPs in reducing toxic activities. Bioassays of AhR and Nrf2 are useful for screening of effects of a broad range of chemicals in drinking water and ER activity can be monitored with a high sensitivity. Copyright © 2018 Elsevier Ltd. All rights reserved.
Molecular analysis of point-of-use municipal drinking water microbiology.
Holinger, Eric P; Ross, Kimberly A; Robertson, Charles E; Stevens, Mark J; Harris, J Kirk; Pace, Norman R
2014-02-01
Little is known about the nature of the microbiology in tap waters delivered to consumers via public drinking water distribution systems (DWDSs). In order to establish a broader understanding of the microbial complexity of public drinking waters we sampled tap water from seventeen different cities between the headwaters of the Arkansas River and the mouth of the Mississippi River and determined the bacterial compositions by pyrosequencing small subunit rRNA genes. Nearly 98% of sequences observed among all systems fell into only 5 phyla: Proteobacteria (35%), Cyanobacteria (29%, including chloroplasts), Actinobacteria (24%, of which 85% were Mycobacterium spp.), Firmicutes (6%), and Bacteroidetes (3.4%). The genus Mycobacterium was the most abundant taxon in the dataset, detected in 56 of 63 samples (16 of 17 cities). Among the more rare phylotypes, considerable variation was observed between systems, and was sometimes associated with the type of source water, the type of disinfectant, or the concentration of the environmental pollutant nitrate. Abundant taxa (excepting Cyanobacteria and chloroplasts) were generally similar from system to system, however, regardless of source water type or local land use. The observed similarity among the abundant taxa between systems may be a consequence of the selective influence of chlorine-based disinfection and the common local environments of DWDS and premise plumbing pipes. Copyright © 2013 Elsevier Ltd. All rights reserved.
Sadeghi, Ramezan; Kobarfard, Farzad; Yazdanpanah, Hassan; Eslamizad, Samira; Bayate, Mitra
2016-01-01
Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and water for injection. Dispersive liquid-liquid microextraction procedure combined with gas chromatography-mass spectrometry was used for the extraction and determination of PAHs in the samples. Under the optimized conditions, the range of extraction recoveries and relative standard deviations (RSDs) of PAHs in water using internal standard (anthracene-d10) were in the range of 71-90% and 4-16%, respectively. Limit of detection for different PAHs were between 0.03 and 0.1 ngmL-1. The concentration of PAHs in all tap water as well as water for injection samples were lower than the limit of quantification of PAHs. This is the first study addressing the occurrence of PAHs in water for injection samples in Iran using dispersive liquid-liquid micro extraction procedure combined with gas chromatography-mass spectrometry. PMID:27642318
Carcinogenic and non-carcinogenic health risks of metal(oid)s in tap water from Ilam city, Iran.
Fakhri, Yadolah; Saha, Narottam; Ghanbari, Sahebeh; Rasouli, Milad; Miri, Ali; Avazpour, Moayed; Rahimizadeh, Aziz; Riahi, Seyed-Mohammad; Ghaderpoori, Mansour; Keramati, Hassan; Moradi, Bigard; Amanidaz, Nazak; Mousavi Khaneghah, Amin
2018-04-20
One of the most important pathways for exposure to metals is drinking water ingestion. Chronic or acute exposure to metals can endanger the health of the exposed population, and hence, estimation of human health risks is crucial. In the current study for the first time, the concentrations of Mercury (Hg), Arsenic (As), Zinc (Zn), Lead (Pb) and Cobalt (Co) in 120 collected tap water samples (2015, July-November) from Ilam city, Iran were investigated using flame atomic absorption spectrophotometer. Also, the metal-induced carcinogenic and non-carcinogenic risks for consumers exposed to tap drinking water were calculated. The average (range) concentrations of Hg, Zn, As, Pb and Co were defined as 0.40 ± 0.10 μg/L (ND-0.9 μg/L), 5014 ± 5707 μg/L (2900.00-5668.33 μg/L), 21.008 ± 2.876 μg/L (3.5-62 μg/L), 30.38 ± 5.56 μg/L (6-87 μg/L), and 11.34 ± 1.61 μg/L (0.1-50 μg/L), respectively. Average concentrations of all examined metals were significantly higher than WHO and national standard recommended limits. The ranking order of metals concentrations in the tap drinking water was Zn > Pb > As > Co > Hg. Except for Hg and Co, at least one age group consumers were at considerable non-carcinogenic risks induced by Zn, As and Pb [Target Hazard Quotient (THQ > 1)]. The rank order of age groups consumers based on THQ and Incremental lifetime cancer risk (ILCR) was <1 years >1-9 years > 20 + years > 10-19 years. The calculated ILCR for As in all age groups were higher than 10 -3 value. All age groups of consumers in Ilam city, especially infants (<1 years) and children (1-10 years), are at considerable non-carcinogenic and carcinogenesis risk. Copyright © 2018 Elsevier Ltd. All rights reserved.
Bengtsson, Daniel; Westerberg, Martin; Nielsen, Susanne; Ridell, Malin; Jönsson, Bodil
2018-04-24
Previous studies have identified patients infected with Mycobacterium chimaera (M. chimaera) subsequent to cardiac surgery. Water tanks in heater-cooler units (HCUs) used cardiac heart surgery was traced as source. The aim was to investigate occurrence of M. chimaera and other microorganisms in HCUs and evaluate the silver-ion cleaning routine. Five HCUs were disinfected with silver-ions and examined for mycobacteria directly (15 min) after the disinfection procedures and later on three occasions (3, 6, 10 weeks). One HCU was selected for additional investigation of the presence of other microorganisms. In addition, tap water from five sinks in the surgical department was examined for the presence of mycobacteria and other microorganisms. M. chimaera grew in all the HCU water tanks and in 35 of the 40 HCU samples. Three of the samples also contained Mycobacterium gordonae. When the selected HCU tanks were analysed directly after the disinfection procedure bacteria and fungi were found but no non-fermenting Gram-negative rods. These HCU samples contained a doubled to 3 fold amount of bacteria compared to initial tap water samples. No mycobacteria were found in any sample from the five water taps. The silver-ion cleaning routine was insufficient and M. chimaera was found in all HCUs. However, no mycobacteria were found in any sample from the five water taps suggesting another source of colonization. It is probable that residual water and biofilm are of importance. Our results emphasize the need for improved disinfection procedures and improved construction of the HCUs.
Health risk assessment of haloacetonitriles in drinking water based on internal dose.
Zhang, Ying; Han, Xuemei; Niu, Zhiguang
2018-05-01
To estimate the health risk of haloacetonitriles in different kinds of drinking water, the concentrations of haloacetonitriles in tap water, boiled water and direct drinking water were detected. The physiologically based pharmacokinetic (PBPK) model was used to calculate internal dose in the human body for haloacetonitriles through ingestion, and the probability distributions of the non-carcinogenic risk of haloacetonitriles for human via drinking water were assessed. This study found that the mean concentrations of dichloroacetonitrile (DCAN) in tap water, boiled water and direct drinking water were 0.955 μg/L, 0.207 μg/L and 0.127 μg/L, and those of dibromoacetonitrile (DBAN) were 0.221 μg/L, 0.104 μg/L, 0.089 μg/L, respectively. In China, direct drinking water is used most frequently, so the concentrations of haloacetonitriles in direct drinking water were used to obtain data on the internal dose of haloacetonitriles. In addition, the simulation results for the PBPK model showed that the highest and lowest concentrations of DCAN occurred in the liver and venous blood, respectively. The peak concentrations of DBAN in each tissue were in the decreasing order liver > rapidly perfused tissue > kidney > slowly perfused tissues > fat > arterial blood (venous blood). In addition, the highest 95th percentile hazard quotients (HQ) value of haloacetonitriles via drinking water for humans was 8.89 × 10 -3 , much lower than 1. The 95th percentile hazard index (HI) was 0.046, which was also lower than 1, suggesting that there was no obvious non-carcinogenic risk. Copyright © 2017 Elsevier Ltd. All rights reserved.
Yang, Xinchao; Wang, Ke; Wang, Huijun; Zhang, Jianhua; Mao, Zhonggui
2017-04-01
A novel cleaner ethanol production process has been developed. Thin stillage is treated initially by anaerobic digestion followed by aerobic digestion and then further treated by chloride anion exchange resin. This allows the fully-digested and resin-treated stillage to be completely recycled for use as process water in the next ethanol fermentation batch, which eliminates wastewater discharges and minimizes consumption of fresh water. The method was evaluated at the laboratory scale. Process parameters were very similar to those found using tap water. Maximal ethanol production rate in the fully-recycled stillage was 0.9g/L/h, which was similar to the 0.9g/L/h found with the tap water control. The consumption of fresh water was reduced from 4.1L/L (fresh water/ethanol) to zero. Compared with anaerobically-aerobically digested stillage which had not been treated with resin, the fermentation time was reduced by 28% (from 72h to 52h) and reached the level achieved with tap water. This novel process can assist in sustainable development of the ethanol industry. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kennedy, Deborah A.; Cooley, Kieran; Einarson, Thomas R.; Seely, Dugald
2012-01-01
Ionic footbaths are often used in holistic health centres and spas to aid in detoxification; however, claims that these machines eliminate toxins from the body have not been rigorously evaluated. In this proof-of-principle study, we sought to measure the release of potentially toxic elements from ionic footbaths into distilled and tap water with and without feet. Water samples were collected and analyzed following 30-minute ionic footbath sessions without feet using both distilled (n = 1) and tap water (n = 6) and following four ionic footbaths using tap water (once/week for 4 weeks) in six healthy participants. Urine collection samples were analyzed at four points during the study. Hair samples were analyzed for element concentrations at baseline and study conclusion. Contrary to claims made for the machine, there does not appear to be any specific induction of toxic element release through the feet when running the machine according to specifications. PMID:22174728
Metal leaching in drinking water domestic distribution system: an Italian case study.
Sorlini, Sabrina; Gialdini, Francesca; Collivignarelli, Carlo
2014-01-01
The objective of this study was to evaluate metal contamination of tap water in seven public buildings in Brescia (Italy). Two monitoring periods were performed using three different sampling methods (overnight stagnation, 30-min stagnation, and random daytime). The results show that the water parameters exceeding the international standards (Directive 98/83/EC) at the tap were lead (max = 363 μg/L), nickel (max = 184 μg/L), zinc (max = 4900 μg/L), and iron (max = 393 μg/L). Compared to the total number of tap water samples analyzed (122), the values higher than limits of Directive 98/83/EC were 17% for lead, 11% for nickel, 14% for zinc, and 7% for iron. Three buildings exceeded iron standard while five buildings exceeded the standard for nickel, lead, and zinc. Moreover, there is no evident correlation between the leaching of contaminants in the domestic distribution system and the age of the pipes while a significant influence is shown by the sampling methods.
Fantin, Valentina; Scalbi, Simona; Ottaviano, Giuseppe; Masoni, Paolo
2014-04-01
The purpose of this study is to propose a method for harmonising Life Cycle Assessment (LCA) literature studies on the same product or on different products fulfilling the same function for a reliable and meaningful comparison of their life-cycle environmental impacts. The method is divided in six main steps which aim to rationalize and quicken the efforts needed to carry out the comparison. The steps include: 1) a clear definition of the goal and scope of the review; 2) critical review of the references; 3) identification of significant parameters that have to be harmonised; 4) harmonisation of the parameters; 5) statistical analysis to support the comparison; 6) results and discussion. This approach was then applied to the comparative analysis of the published LCA studies on tap and bottled water production, focussing on Global Warming Potential (GWP) results, with the aim to identify the environmental preferable alternative. A statistical analysis with Wilcoxon's test confirmed that the difference between harmonised GWP values of tap and bottled water was significant. The results obtained from the comparison of the harmonised mean GWP results showed that tap water always has the best environmental performance, even in case of high energy-consuming technologies for drinking water treatments. The strength of the method is that it enables both performing a deep analysis of the LCA literature and obtaining more consistent comparisons across the published LCAs. For these reasons, it can be a valuable tool which provides useful information for both practitioners and decision makers. Finally, its application to the case study allowed both to supply a description of systems variability and to evaluate the importance of several key parameters for tap and bottled water production. The comparative review of LCA studies, with the inclusion of a statistical decision test, can validate and strengthen the final statements of the comparison. Copyright © 2014 Elsevier B.V. All rights reserved.
Etchevers, Anne; Le Tertre, Alain; Lucas, Jean-Paul; Bretin, Philippe; Oulhote, Youssef; Le Bot, Barbara; Glorennec, Philippe
2015-01-01
Blood lead levels (BLLs) have substantially decreased in recent decades in children in France. However, further reducing exposure is a public health goal because there is no clear toxicological threshold. The identification of the environmental determinants of BLLs as well as risk factors associated with high BLLs is important to update prevention strategies. We aimed to estimate the contribution of environmental sources of lead to different BLLs in children in France. We enrolled 484 children aged from 6months to 6years, in a nationwide cross-sectional survey in 2008-2009. We measured lead concentrations in blood and environmental samples (water, soils, household settled dusts, paints, cosmetics and traditional cookware). We performed two models: a multivariate generalized additive model on the geometric mean (GM), and a quantile regression model on the 10th, 25th, 50th, 75th and 90th quantile of BLLs. The GM of BLLs was 13.8μg/L (=1.38μg/dL) (95% confidence intervals (CI): 12.7-14.9) and the 90th quantile was 25.7μg/L (CI: 24.2-29.5). Household and common area dust, tap water, interior paint, ceramic cookware, traditional cosmetics, playground soil and dust, and environmental tobacco smoke were associated with the GM of BLLs. Household dust and tap water made the largest contributions to both the GM and the 90th quantile of BLLs. The concentration of lead in dust was positively correlated with all quantiles of BLLs even at low concentrations. Lead concentrations in tap water above 5μg/L were also positively correlated with the GM, 75th and 90th quantiles of BLLs in children drinking tap water. Preventative actions must target household settled dust and tap water to reduce the BLLs of children in France. The use of traditional cosmetics should be avoided whereas ceramic cookware should be limited to decorative purposes. Copyright © 2014 Elsevier Ltd. All rights reserved.
Kendrick, Denise; Stewart, Jane; Coupland, Carol; Hayes, Michael; Hopkins, Nick; McCabe, Debbie; Murphy, Robert; O'Donnell, George; Phillips, Ceri; Radford, David; Ryan, Jackie; Smith, Sherie; Groom, Lindsay; Towner, Elizabeth
2008-01-01
Background Each year in the UK 2000 children attend emergency departments and 500 are admitted to hospital following a bath water scald. The long term effects can include disability, disfigurement or psychological harm and repeated skin grafts may be required as the child grows. The costs of treating a severe scald are estimated at 250,000 GBP. Children living in the most deprived wards are at greatest risk of thermal injuries; hospital admission rates are three times that for children living in the least deprived wards. Domestic hot water, which is usually stored at around 60 degrees Celsius, can result in a second-degree burn after 3 seconds and a third-degree burn after 5 seconds. Educational strategies to encourage testing of tap water temperature and reduction of hot water thermostat settings have largely proved unsuccessful. Legislation in the USA mandating pre-setting hot water heater thermostats at 49 degrees Celsius was effective in reducing scald injuries, suggesting passive measures may have a greater impact. Thermostatic mixer valves (TMVs), recently developed for the domestic market, fitted across the hot and cold water supply pipes of the bath, allow delivery of water set at a fixed temperature from the hot bath tap. These valves therefore offer the potential to reduce scald injuries. Design/Methods A pragmatic, randomised controlled trial to assess the effectiveness of TMVs in reducing bath hot tap water temperatures in the homes of families with young children in rented social housing. Two parallel arms include an intervention group and a control group where the intervention will be deferred. The intervention will consist of fitting a TMV (set at 44 degrees Celsius) by a qualified plumber and provision of educational materials. The control arm will not receive a TMV or the educational materials for the study duration but will be offered the intervention after collection of follow-up data 12 months post randomisation. The primary outcome measure will be the bath hot tap water temperature. Fifteen families per arm are required to detect a reduction in the mean bath hot tap water temperature from 60.4 degrees Celsius (SD 9.1) in the control group to 46 degrees Celsius in the intervention group, with 90% power and a 5% significance level (2 sided). Secondary outcome measures including acceptability will require a sample size of 120 participants. Discussion Whilst TMVs have the potential to reduce scald injuries, to date there have been no randomised controlled trials assessing their effectiveness, acceptability and cost effectiveness. Trial Registration ISRCTN21179067 PMID:18348736
Assessment of Drinking Water Quality from Bottled Water Coolers
FARHADKHANI, Marzieh; NIKAEEN, Mahnaz; AKBARI ADERGANI, Behrouz; HATAMZADEH, Maryam; NABAVI, Bibi Fatemeh; HASSANZADEH, Akbar
2014-01-01
Abstract Background Drinking water quality can be deteriorated by microbial and toxic chemicals during transport, storage and handling before using by the consumer. This study was conducted to evaluate the microbial and physicochemical quality of drinking water from bottled water coolers. Methods A total of 64 water samples, over a 5-month period in 2012-2013, were collected from free standing bottled water coolers and water taps in Isfahan. Water samples were analyzed for heterotrophic plate count (HPC), temperature, pH, residual chlorine, turbidity, electrical conductivity (EC) and total organic carbon (TOC). Identification of predominant bacteria was also performed by sequence analysis of 16S rDNA. Results The mean HPC of water coolers was determined at 38864 CFU/ml which exceeded the acceptable level for drinking water in 62% of analyzed samples. The HPC from the water coolers was also found to be significantly (P < 0.05) higher than that of the tap waters. The statistical analysis showed no significant difference between the values of pH, EC, turbidity and TOC in water coolers and tap waters. According to sequence analysis eleven species of bacteria were identified. Conclusion A high HPC is indicative of microbial water quality deterioration in water coolers. The presence of some opportunistic pathogens in water coolers, furthermore, is a concern from a public health point of view. The results highlight the importance of a periodic disinfection procedure and monitoring system for water coolers in order to keep the level of microbial contamination under control. PMID:26060769
Walker, J T; Jhutty, A; Parks, S; Willis, C; Copley, V; Turton, J F; Hoffman, P N; Bennett, A M
2014-01-01
In December 2011 and early 2012 four neonates died from Pseudomonas aeruginosa bacteraemia in hospitals in Northern Ireland. To assess whether P. aeruginosa was associated with the neonatal unit taps and whether waterborne isolates were consistent with patient isolates. Thirty taps and eight flow straighteners from the relevant hospitals were categorized and dismantled into 494 components and assessed for aerobic colony and P. aeruginosa counts using non-selective and selective agars. P. aeruginosa isolates were typed by variable number tandem repeat (VNTR) analysis. Selected tap components were subjected to epifluorescence and scanning electron microscopy to visualize biofilm. The highest P. aeruginosa counts were from the flow straighteners, metal support collars and the tap bodies surrounding these two components. Complex flow straighteners had a significantly higher P. aeruginosa count than other types of flow straighteners (P < 0.05). Highest aerobic colony counts were associated with integrated mixers and solenoids (P < 0.05), but there was not a strong correlation (r = 0.33) between the aerobic colony counts and P. aeruginosa counts. Representative P. aeruginosa tap isolates from two hospital neonatal units had VNTR profiles consistent with strains from the tap water and infected neonates. P. aeruginosa was predominantly found in biofilms in flow straighteners and associated components in the tap outlets and was a possible source of the infections observed. Healthcare providers should be aware that water outlets can be a source of P. aeruginosa contamination and should take steps to reduce such contamination, monitor it and have strategies to minimize risk to susceptible patients. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Yang, Jin-Young; Lee, Eun-Sook; Kim, Se-Chul; Cha, So-Yang; Kim, Sung-Tek; Lee, Man-Ho; Han, Sun-Hee; Park, Young-Sang
2013-01-01
From May to June 2012, a waterborne outbreak of 124 cases of cryptosporidiosis occurred in the plumbing systems of an older high-rise apartment complex in Seoul, Republic of Korea. The residents of this apartment complex had symptoms of watery diarrhea and vomiting. Tap water samples in the apartment complex and its adjacent buildings were collected and tested for 57 parameters under the Korean Drinking Water Standards and for additional 11 microbiological parameters. The microbiological parameters included total colony counts, Clostridium perfringens, Enterococcus, fecal streptococcus, Salmonella, Shigella, Pseudomonas aeruginosa, Cryptosporidium oocysts, Giardia cysts, total culturable viruses, and Norovirus. While the tap water samples of the adjacent buildings complied with the Korean Drinking Water Standards for all parameters, fecal bacteria and Cryptosporidium oocysts were detected in the tap water samples of the outbreak apartment complex. It turned out that the agent of the disease was Cryptosporidium parvum. The drinking water was polluted with sewage from a septic tank in the apartment complex. To remove C. parvum oocysts, we conducted physical processes of cleaning the water storage tanks, flushing the indoor pipes, and replacing old pipes with new ones. Finally we restored the clean drinking water to the apartment complex after identification of no oocysts. PMID:24039290
Fitzpatrick, D.J.
1982-01-01
As a result of declining water levels and saltwater intrusion in the Cape Coral area, the U.S. Geological Survey, in cooperation with the City of Cape Coral, established a monitor well network in Cape Coral and adjacent areas in 1978. The network was designed to monitor water levels and water quality, to collect background data from water-bearing zones in the upper and lower parts of the Hawthorn Formation, the upper part of the Tampa Formation, and the surficial aquifer. A network of 34 wells tapping the artesian freshwater-bearing aquifer in the upper part of the Hawthorn Formation was established, and water-quality samples were collected and analyzed semiannually from 1978-80. Water levels in selected wells were monitored continuously or measured monthly, bimonthly, or semiannually for general trends. Thirty-six wells tapping the surficial and six wells tapping the artesian aquifer in the lower part of the Hawthorn Formation were constructed. Selected wells in these aquifers have also been monitored for water levels continuously, or at monthly, bimonthly, or semiannual intervals. Water-quality data were collected from selected wells for background information. Lithologic logs were prepared for 18 wells penetrating one or more of the three aquifers. (USGS)
Cho, Eun-Joo; Yang, Jin-Young; Lee, Eun-Sook; Kim, Se-Chul; Cha, So-Yang; Kim, Sung-Tek; Lee, Man-Ho; Han, Sun-Hee; Park, Young-Sang
2013-08-01
From May to June 2012, a waterborne outbreak of 124 cases of cryptosporidiosis occurred in the plumbing systems of an older high-rise apartment complex in Seoul, Republic of Korea. The residents of this apartment complex had symptoms of watery diarrhea and vomiting. Tap water samples in the apartment complex and its adjacent buildings were collected and tested for 57 parameters under the Korean Drinking Water Standards and for additional 11 microbiological parameters. The microbiological parameters included total colony counts, Clostridium perfringens, Enterococcus, fecal streptococcus, Salmonella, Shigella, Pseudomonas aeruginosa, Cryptosporidium oocysts, Giardia cysts, total culturable viruses, and Norovirus. While the tap water samples of the adjacent buildings complied with the Korean Drinking Water Standards for all parameters, fecal bacteria and Cryptosporidium oocysts were detected in the tap water samples of the outbreak apartment complex. It turned out that the agent of the disease was Cryptosporidium parvum. The drinking water was polluted with sewage from a septic tank in the apartment complex. To remove C. parvum oocysts, we conducted physical processes of cleaning the water storage tanks, flushing the indoor pipes, and replacing old pipes with new ones. Finally we restored the clean drinking water to the apartment complex after identification of no oocysts.
Pasquarella, Cesira; Veronesi, Licia; Napoli, Christian; Castiglia, Paolo; Liguori, Giorgio; Rizzetto, Rolando; Torre, Ida; Righi, Elena; Farruggia, Patrizia; Tesauro, Marina; Torregrossa, Maria V; Montagna, Maria T; Colucci, Maria E; Gallè, Francesca; Masia, Maria D; Strohmenger, Laura; Bergomi, Margherita; Tinteri, Carola; Panico, Manuela; Pennino, Francesca; Cannova, Lucia; Tanzi, Marialuisa
2012-03-15
A microbiological environmental investigation was carried out in ten dental clinics in Italy. Microbial contamination of water, air and surfaces was assessed in each clinic during the five working days, for one week per month, for a three-month period. Water and surfaces were sampled before and after clinical activity; air was sampled before, after, and during clinical activity. A wide variation was found in microbial environmental contamination, both within the participating clinics and for the different sampling times. Before clinical activity, microbial water contamination in tap water reached 51,200cfu/mL (colony forming units per milliliter), and that in Dental Unit Water Systems (DUWSs) reached 872,000cfu/mL. After clinical activity, there was a significant decrease in the Total Viable Count (TVC) in tap water and in DUWSs. Pseudomonas aeruginosa was found in 2.38% (7/294) of tap water samples and in 20.06% (59/294) of DUWS samples; Legionella spp. was found in 29.96% (89/297) of tap water samples and 15.82% (47/297) of DUWS samples, with no significant difference between pre- and post-clinical activity. Microbial air contamination was highest during dental treatments, and decreased significantly at the end of the working activity (p<0.05). The microbial buildup on surfaces increased significantly during the working hours. This study provides data for the establishment of standardized sampling methods, and threshold values for contamination monitoring in dentistry. Some very critical situations have been observed which require urgent intervention. Furthermore, the study emphasizes the need for research aimed at defining effective managing strategies for dental clinics. Copyright © 2012 Elsevier B.V. All rights reserved.
Pilot evaluation of the efficacy of shampoo treatment with ultrapure soft water for canine pruritus.
Ohmori, Keitaro; Tanaka, Akane; Makita, Yuka; Takai, Masaki; Yoshinari, Yuji; Matsuda, Hiroshi
2010-10-01
Ultrapure soft water (UPSW) is water in which calcium and magnesium ions have been replaced with sodium ions using a cation-exchange resin. We recently demonstrated that washing with soap and UPSW reduced the clinical severity of dermatitis and improved the skin barrier function in NC/NgaTnd mice, a murine model for human atopic dermatitis. The purpose of this pilot study was to evaluate the efficacy of shampoo treatment with UPSW for dogs with pruritus. Eleven dogs with pruritus were randomly assigned to two groups depending on whether they received weekly shampoo treatment with UPSW or tap water for 4 weeks. After a washout period, the treatment protocol was switched such that each dog received both treatments. The pre-treatment and post-treatment values of the following were compared: pruritus scores assessed by the owners; dermatitis scores recorded by an investigator; and transepidermal water loss (TEWL). Shampoo treatment with UPSW significantly decreased pruritus and dermatitis scores in the dogs, whereas shampoo treatment with tap water did not. In addition, shampoo treatment with UPSW, but not with tap water, significantly reduced TEWL in the dogs. Adverse events due to the treatment were not observed in the dogs. Furthermore, we found that topical application of UPSW for barrier-disrupted skin caused by tape stripping in healthy dogs decreased TEWL more rapidly than topical application of tap water. Our findings suggest that shampoo treatment with UPSW promotes skin barrier recovery and thus could be considered as a possible therapeutic option in the management of pruritus and dermatitis in dogs. © 2010 The Authors. Journal compilation © 2010 ESVD and ACVD.
Cai, Mei-Quan; Wang, Rong; Feng, Li; Zhang, Li-Qiu
2015-02-01
A simultaneous determination method of 14 multi-class pharmaceuticals using solid-phase extraction (SPE) followed by high-performance liquid chromatography-tandem mass spectrometer (HPLC-MS/MS) was established to measure the occurrence and distribution of these pharmaceuticals in tap water and a drinking water treatment plant (DWTP) in Beijing, China. Target compounds included seven anti-inflammatory drugs, two antibacterial drugs, two lipid regulation drugs, one antiepileptic drug, and one hormone. Limits of detection (LODs) and limits of quantitation (LOQs) ranged from 0.01 to 1.80 ng/L and 0.05 to 3.00 ng/L, respectively. Intraday and inter-day precisions, recoveries of different matrices, and matrix effects were also investigated. Of the 14 pharmaceutical compounds selected, nine were identified in tap water of Beijing downtown with the concentration up to 38.24 ng/L (carbamazepine), and the concentration levels of detected pharmaceuticals in tap water (<5 ng/L for most pharmaceuticals) were lower than previous studies in other countries. In addition, ten and six pharmaceuticals were measured in raw water and finished water at the concentration ranged from 0.10 to 16.23 and 0.13 to 17.17 ng/L, respectively. Five compounds were detected most frequently in DWTP, namely antipyrine, carbamazepine, isopropylantipyrine, aminopyrine, and bezafibrate. Ibuprofen was found to be the highest concentration pharmaceutical during DWTP, up to 53.30 ng/L. DWTP shows a positive effect on the removal of most pharmaceuticals with 81.2-99.5 % removal efficiencies, followed by carbamazepine with 55.4 % removal efficiency, but it has no effect for removing ibuprofen and bezafibrate.
Beneficial effect of sulphate-bicarbonate-calcium water on gallstone risk and weight control
Corradini, Stefano Ginanni; Ferri, Flaminia; Mordenti, Michela; Iuliano, Luigi; Siciliano, Maria; Burza, Maria Antonella; Sordi, Bruno; Caciotti, Barbara; Pacini, Maria; Poli, Edoardo; Santis, Adriano De; Roda, Aldo; Colliva, Carolina; Simoni, Patrizia; Attili, Adolfo Francesco
2012-01-01
AIM: To investigate the effect of drinking sulphate-bicarbonate-calcium thermal water (TW) on risk factors for atherosclerosis and cholesterol gallstone disease. METHODS: Postmenopausal women with functional dyspepsia and/or constipation underwent a 12 d cycle of thermal (n = 20) or tap (n = 20) water controlled drinking. Gallbladder fasting volume at ultrasound, blood vitamin E, oxysterols (7-β-hydroxycholesterol and 7-ketocholesterol), bile acid (BA), triglycerides, total/low density lipoprotein and high density lipoprotein cholesterol were measured at baseline and at the end of the study. Food consumption, stool frequency and body weight were recorded daily. RESULTS: Blood lipids, oxysterols and vitamin E were not affected by either thermal or tap water consumption. Fasting gallbladder volume was significantly (P < 0.005) smaller at the end of the study than at baseline in the TW (15.7 ± 1.1 mL vs 20.1 ± 1.7 mL) but not in the tap water group (19.0 ± 1.4 mL vs 19.4 ± 1.5 mL). Total serum BA concentration was significantly (P < 0.05) higher at the end of the study than at baseline in the TW (5.83 ± 1.24 μmol vs 4.25 ± 1.00 μmol) but not in the tap water group (3.41 ± 0.46 μmol vs 2.91 ± 0.56 μmol). The increased BA concentration after TW consumption was mainly accounted for by glycochenodeoxycholic acid. The number of pasta (P < 0.001), meat (P < 0.001) and vegetable (P < 0.005) portions consumed during the study and of bowel movements per day (P < 0.05) were significantly higher in the TW than in the tap water group. Body weight did not change at the end of the study as compared to baseline in both groups. CONCLUSION: Sulphate-bicarbonate-calcium water consumption has a positive effect on lithogenic risk and intestinal transit and allows maintenance of a stable body weight despite a high food intake. PMID:22408352
NASA Astrophysics Data System (ADS)
khan, Shaukat Ali; Ayaz, Sultan; Khan, Sanaullah; Anees, Muhammad; Khan, Amir Muhammad; Khan, Imran
2012-12-01
Giardia lamblia is a cosmopolitan parasite that occurs worldwide and generally effects gastrointestinal tract. Water played a media for transmission of Giardia to different hosts. A total of 300 water samples were examined from different water sources, i.e. tap, open well, bore well and drain waters and DNA was extracted by trizol method through prescribed protocol. DNA was amplified through PCR. The overall prevalence of G. lamblia was 27.66% (83/300). Among these 2.5% (1/40) in bore well water, 29% (29/100) open well, 18.83% (11/60) tap water and 42% (42/100) drain water. It is concluded from the study that Giardia is frequently found in all water sources and is the main cause of ill health.
Lead and Copper Tap Sample Site Plan Instructions
This document may be used by public water systems in Wyoming and on EPA R8 Tribal Lands as a guide for how to properly complete their lead and copper tap sample site plans to comply with the Lead and Copper Rule.
Harvested rainwater quality before and after treatment in six ...
Rainwater harvesting (RWH) is an alternative method of providing water for indoor domestic use, but the water quality after treatment and distribution at individual residences is not well documented. In this study, water quality parameters were measured at the cistern and indoor cold-water taps of six residential RWH systems that use various treatment processes. Potential human pathogens (Mycobacterium avium, Mycobacterium intracellulare, Aspergillus flavus, Aspergillus fumigatus, and Aspergillus niger) were found frequently in cisterns and in treated rainwater delivered at the tap; Legionella pneumophila was not detected as frequently, but it persisted in a system after its first detection. The observed decreases in bacterial concentrations from the cistern to the tap after filtration/ ultraviolet (UV) treatment and distribution were less than expected; this suggests deficiencies in the effectiveness of the filtration/UV processes employed and/or degradation in water quality in the distribution system due to the absence of a disinfectant residual. Determination of the disinfection efficiency occuring in home treatment processes. Molecular analysis of rainwater before and after treatment. First study to include the monitoring of opportunistic fungal pathogens.
Moslemi, Mohammad Kazem; Saghafi, Hossein; Joorabchin, Seyed Mohammad Amin
2011-01-01
The aim of this study was to evaluate the biochemical stone composition in general population of Qom province, central Iran, and its relationship with high tap water hardness. In a prospective study, from March 2008 to July 2011, biochemical analysis of urinary stones in patients living in Qom province for at least 5 years was performed. Stones were retrieved by spontaneous passage, endoscopic or open surgery, and after extracorporeal shockwave lithotripsy. Demographic findings and the drinking water supply of patients were evaluated and compared with biochemical stone analysis. Stone analysis was performed in 255 patients. The most dominant composition of urinary stones was calcium oxalate (73%), followed by uric acid (24%), ammonium urate (2%), and cystine (1%). The peak incidence of urinary stone was in patients in their forties. Overall male to female ratio was 4.93:1. The dominant stone composition in inhabitants of central Iran, where tap water hardness is high, was calcium oxalate stones. On the basis of this study, biochemical urinary stone composition of Qom does not differ from other regions of Iran with lower water hardness.
The purpose of this SOP is to describe how to collect, store, and ship tap and drinking water samples for analysis by EPA Method 200.8 (revision 4.4) for the NHEXAS Arizona project. This SOP provides a brief description of the sample containers, collection, preservation, storage...
Off-vertical rotation produces conditioned taste aversion and suppressed drinking in mice
NASA Technical Reports Server (NTRS)
Fox, R. A.; Lauber, A. H.; Daunton, N. G.; Phillips, M.; Diaz, L.
1984-01-01
The effects of off-vertical rotation upon the intake of tap water immediately after rotation and upon conditioned taste aversion were assessed in mice with the tilt of the rotation axis varying from 5 to 20 deg from the earth-vertical. Conditioned taste aversion occurred in all mice that were rotated, but the intake of tap water was suppressed only in mice that were rotated at 15 or 20 deg of tilt. The greater suppression of tap-water intake and the stronger conditioned aversion in the mouse as the angle of tilt was increased in this experiment are consistent with predictions from similar experiments with human subjects, where motion sickness develops more rapidly as the angle of tilt is increased. It was suggested that off-vertical rotation may be a useful procedure for insuring experimental control over vestibular stimulation in animal studies of motion sickness.
Using Acid-Base Reagent Problems as a High School Science Research Activity.
ERIC Educational Resources Information Center
Schlenker, Richard M.; Cullen, David; Schlenker, Karl R.
1999-01-01
Describes an open-ended activity in which students try to determine the factors that contribute to an unusual chemical reaction. Uses a case study approach to show students how the presence of chlorine in tap water can interfere with a pH indicator. Includes assessment guidelines and extension activities. (WRM)
The efficiency of the heat pump water heater, during DHW tapping cycle
NASA Astrophysics Data System (ADS)
Gużda, Arkadiusz; Szmolke, Norbert
2017-10-01
This paper discusses one of the most effective systems for domestic hot water (DHW) production based on air-source heat pump with an integrated tank. The operating principle of the heat pump is described in detail. Moreover, there is an account of experimental set-up and results of the measurements. In the experimental part, measurements were conducted with the aim of determining the energy parameters and measures of the economic efficiency related to the presented solution. The measurements that were conducted are based on the tapping cycle that is similar to the recommended one in EN-16147 standard. The efficiency of the air source heat pump during the duration of the experiment was 2.43. In the end of paper, authors conducted a simplified ecological analysis in order to determine the influence of operation of air-source heat pump with integrated tank on the environment. Moreover the compression with the different source of energy (gas boiler with closed combustion chamber and boiler fired by the coal) was conducted. The heat pump is the ecological friendly source of the energy.
Electrodialytic in-line preconcentration for ionic solute analysis.
Ohira, Shin-Ichi; Yamasaki, Takayuki; Koda, Takumi; Kodama, Yuko; Toda, Kei
2018-04-01
Preconcentration is an effective way to improve analytical sensitivity. Many types of methods are used for enrichment of ionic solute analytes. However, current methods are batchwise and include procedures such as trapping and elution. In this manuscript, we propose in-line electrodialytic enrichment of ionic solutes. The method can enrich ionic solutes within seconds by quantitative transfer of analytes from the sample solution to the acceptor solution under an electric field. Because of quantitative ion transfer, the enrichment factor (the ratio of the concentration in the sample and to that in the obtained acceptor solution) only depends on the flow rate ratio of the sample solution to the acceptor solution. The ratios of the concentrations and flow rates are equal for ratios up to 70, 20, and 70 for the tested ionic solutes of inorganic cations, inorganic anions, and heavy metal ions, respectively. The sensitivity of ionic solute determinations is also improved based on the enrichment factor. The method can also simultaneously achieve matrix isolation and enrichment. The method was successively applied to determine the concentrations of trace amounts of chloroacetic acids in tap water. The regulated concentration levels cannot be determined by conventional high-performance liquid chromatography with ultraviolet detection (HPLC-UV) without enrichment. However, enrichment with the present method is effective for determination of tap water quality by improving the limits of detection of HPLC-UV. The standard addition test with real tap water samples shows good recoveries (94.9-109.6%). Copyright © 2017 Elsevier B.V. All rights reserved.
Spatial Distribution of Nitrate in Mizoro-Ga a Pond with Floating at Bog
NASA Astrophysics Data System (ADS)
Shimamura, Tetsuya; Takemon, Yasuhiro; Osaka, Ken'ichi; Itoh, Masayuki; Ohte, Nobuhito
Artificial nutrient loading has been linked to the decrease in plant diversity in peatlands, riparian areas, and swamps. Mizoro-ga-ike pond is one of the natural monuments of Japan and contains temperate floating mat and diverse plant community. The pond had experienced eutrophication by sewage and tap water. As the inflows of nutrient-rich water had been lessened, the amount of source area of the pond has decreased to 30%. We investigated factors that control water chemistry in and around the pond to assess the present situation of the pond. The pond has two mouths of inflows. One of the inflows includes leaked water from a tap water reserver. The other is the surface flow collected by a ditch. The result of water quality census indicates the pond has two sources of nutrient-rich water. One is the drainage from the surface water polluted by the road for automobile that flows into the northern coast of the pond, and the other is the tap water-contaminated water entering from the southern coast. Also the result of the census indicates that emergent plants such as reeds and wild rice modify the effect of nutrient-rich water by exploiting nutrients. Especially, it was suggested that the nursery effects of emergent grasslands that spread southern part of the pond protect the less robust plants, Nuphar subintegerrimum.
Spatial Distribution of Nitrate in Mizoro-Ga a Pond with Floating Mat Bog
NASA Astrophysics Data System (ADS)
Shimamura, Tetsuya; Takemon, Yasuhiro; Osaka, Ken'ichi; Itoh, Masayuki; Ohte, Nobuhito
Artificial nutrient loading has been linked to the decrease in plant diversity in peatlands, riparian areas, and swamps. Mizoro-ga-ike pond is one of the natural monuments of Japan and contains temperate floating mat and diverse plant community. The pond had experienced eutrophication by sewage and tap water. As the inflows of nutrient-rich water had been lessened, the amount of source area of the pond has decreased to 30%. We investigated factors that control water chemistry in and around the pond to assess the present situation of the pond. The pond has two mouths of inflows. One of the inflows includes leaked water from a tap water reserver. The other is the surface flow collected by a ditch. The result of water quality census indicates the pond has two sources of nutrient-rich water. One is the drainage from the surface water polluted by the road for automobile that flows into the northern coast of the pond, and the other is the tap water-contaminated water entering from the southern coast. Also the result of the census indicates that emergent plants such as reeds and wild rice modify the effect of nutrient-rich water by exploiting nutrients. Especially, it was suggested that the nursery effects of emergent grasslands that spread southern part of the pond protect the less robust plants, Nuphar subintegerrimum.
A simple optode based method for imaging O2 distribution and dynamics in tap water biofilms.
Staal, M; Prest, E I; Vrouwenvelder, J S; Rickelt, L F; Kühl, M
2011-10-15
A ratiometric luminescence intensity imaging approach is presented, which enables spatial O2 measurements in biofilm reactors with transparent planar O2 optodes. Optodes consist of an O2 sensitive luminescent dye immobilized in a 1-10 μm thick polymeric layer on a transparent carrier, e.g. a glass window. The method is based on sequential imaging of the O2 dependent luminescence intensity, which are subsequently normalized with luminescent intensity images recorded under anoxic conditions. We present 2-dimensional O2 distribution images at the base of a tap water biofilm measured with the new ratiometric method and compare the results with O2 distribution images obtained in the same biofilm reactor with luminescence lifetime imaging. Using conventional digital cameras, such simple normalized luminescence intensity imaging can yield images of 2-dimensional O2 distributions with a high signal-to-noise ratio and spatial resolution comparable or even surpassing those obtained with expensive and complex luminescence lifetime imaging systems. The method can be applied to biofilm growth incubators allowing intermittent experimental shifts to anoxic conditions or in systems, in which the O2 concentration is depleted during incubation. Copyright © 2011 Elsevier Ltd. All rights reserved.
Li, Huan; Li, Shang; Tang, Wei; Yang, Yang; Zhao, Jianfu; Xia, Siqing; Zhang, Weixian; Wang, Hong
2018-06-01
Secondary water supply systems (SWSSs) refer to the in-building infrastructures (e.g., water storage tanks) used to supply water pressure beyond the main distribution systems. The purpose of this study was to investigate the influence of SWSSs on microbial community structure and the occurrence of opportunistic pathogens, the latter of which are an emerging public health concern. Higher numbers of bacterial 16S rRNA genes, Legionella and mycobacterial gene markers were found in public building taps served by SWSSs relative to the mains, regardless of the flushing practice (P < 0.05). In residential buildings, genes of L. pneumomhila, Acanthamoeba and Vermamoeba vermiformis were primarily detected in tanks and taps compared to the mains. Long water retention time, warm temperature and loss of disinfectant residuals promoted microbial growth and colonization of potential pathogens in SWSSs. Varied levels of microbial community shifts were found in different types of SWSSs during water transportation from the distribution main to taps, highlighting the critical role of SWSSs in shaping the drinking water microbiota. Overall, the results provided insight to factors that might aid in controlling pathogen proliferation in real-world water systems using SWSSs. Copyright © 2018 Elsevier Ltd. All rights reserved.
Zhang, Hongbo; Liu, Guanshan; Timko, Michael P; Li, Jiana; Wang, Wenjing; Ma, Haoran
2014-10-21
Water quality is under increasing threat from industrial and natural sources of pollutants. Here, we present our findings about a pollution incident involving the tap water of Chongqing City in China. In recent years, Solanaceae plants grown in greenhouses in this city have displayed symptoms of cupped, strappy leaves. These symptoms resembled those caused by chlorinated auxinic herbicides. We have determined that these symptoms were caused by the tap water used for irrigation. Using a bioactivity-guided fractionation method, we isolated a substance with corresponding auxinic activity from the tap water. The substance was named "solanicide" because of its strong bioactivity against Solanaceae plants. Further investigation revealed that the solanicide in the water system of Chongqing City is derived from the Jialing River, a major tributary of the Yangtze River. Therefore, it is also present in the Yangtze River downstream of Chongqing after the inflow of the Jialing River. Biological analyses indicated that solanicide is functionally similar to, but distinct from, other known chlorinated auxinic herbicides. Chemical assays further showed that solanicide structurally differs from those compounds. This study has highlighted a water pollution threat to the Yangtze River and its floodplain ecosystem.
Patze, Sophie; Huebner, Uwe; Liebold, Falk; Weber, Karina; Cialla-May, Dana; Popp, Juergen
2017-01-01
Sulfamethoxazole (SMX) is a commonly applied antibiotic for treating urinary tract infections; however, allergic reactions and skin eczema are known side effects that are observed for all sulfonamides. Today, this molecule is present in drinking and surface water sources. The allowed concentration in tap water is 2·10 -7 mol L -1 . SMX could unintentionally be ingested by healthy people when drinking contaminated tap water, representing unnecessary drug intake. To assess the quality of tap water, fast, specific and sensitive detection methods are required, in which consequence measures for improving the purification of water might be initiated in the short term. Herein, the quantitative detection of SMX down to environmentally and physiologically relevant concentrations in the nanomolar range by employing surface-enhanced Raman spectroscopy (SERS) and a microfluidic cartridge system is presented. By applying surface-water samples as matrices, the detection of SMX down to 2.2·10 -9 mol L -1 is achieved, which illustrates the great potential of our proposed method in environmental science. Copyright © 2016 Elsevier B.V. All rights reserved.
Ingestion, inhalation, and dermal exposures to chloroform and trichloroethene from tap water.
Weisel, C P; Jo, W K
1996-01-01
Individuals are exposed to volatile compounds present in tap water by ingestion, inhalation, and dermal absorption. Traditional risk assessments for water often only consider ingestion exposure to toxic chemicals, even though showering has been shown to increase the body burden of certain chemicals due to inhalation exposure and dermal absorption. We collected and analyzed time-series samples of expired alveolar breath to evaluate changes in concentrations of volatile organic compounds being expired, which reflects the rate of change in the bloodstream due to expiration, metabolism, and absorption into tissues. Analysis of chloroform and trichloethene in expired breath, compounds regulated in water, was also used to determine uptake from tap water by each route (inhalation, ingestion, or absorption). Each route of exposure contributed to the total exposure of these compounds from daily water use. Further, the ingestion dose was completely metabolized before entering the bloodstream, whereas the dose from the other routes was dispersed throughout the body. Thus, differences in potential biologically effective doses depend on route, target organ, and whether the contaminant or metabolite is the biologically active agent. Images Figure 1. A Figure 1. B Figure 1. C Figure 2. A Figure 2. B PMID:8834861
Jalava, Katri; Rintala, Hanna; Ollgren, Jukka; Maunula, Leena; Gomez-Alvarez, Vicente; Revez, Joana; Palander, Marja; Antikainen, Jenni; Kauppinen, Ari; Räsänen, Pia; Siponen, Sallamaari; Nyholm, Outi; Kyyhkynen, Aino; Hakkarainen, Sirpa; Merentie, Juhani; Pärnänen, Martti; Loginov, Raisa; Ryu, Hodon; Kuusi, Markku; Siitonen, Anja; Miettinen, Ilkka; Santo Domingo, Jorge W; Hänninen, Marja-Liisa; Pitkänen, Tarja
2014-01-01
Failures in the drinking water distribution system cause gastrointestinal outbreaks with multiple pathogens. A water distribution pipe breakage caused a community-wide waterborne outbreak in Vuorela, Finland, July 2012. We investigated this outbreak with advanced epidemiological and microbiological methods. A total of 473/2931 inhabitants (16%) responded to a web-based questionnaire. Water and patient samples were subjected to analysis of multiple microbial targets, molecular typing and microbial community analysis. Spatial analysis on the water distribution network was done and we applied a spatial logistic regression model. The course of the illness was mild. Drinking untreated tap water from the defined outbreak area was significantly associated with illness (RR 5.6, 95% CI 1.9-16.4) increasing in a dose response manner. The closer a person lived to the water distribution breakage point, the higher the risk of becoming ill. Sapovirus, enterovirus, single Campylobacter jejuni and EHEC O157:H7 findings as well as virulence genes for EPEC, EAEC and EHEC pathogroups were detected by molecular or culture methods from the faecal samples of the patients. EPEC, EAEC and EHEC virulence genes and faecal indicator bacteria were also detected in water samples. Microbial community sequencing of contaminated tap water revealed abundance of Arcobacter species. The polyphasic approach improved the understanding of the source of the infections, and aided to define the extent and magnitude of this outbreak.
Transportation Air Pollution Studies (TAPS) System
DOT National Transportation Integrated Search
1974-03-01
This report describes the Transportation Air Pollution Studies (TAPS) Data Base and the Software System which has been developed in association with it. : The TAPS Data Base will be used to store the transportation air pollution data (including emiss...
The purpose of this SOP is to describe how to collect, store, and ship tap and drinking water samples for analysis by EPA Method 525.2 (revision 1.0) and EPA method 531.1 (revision 3). This SOP provides a brief description of the sample containers, collection, preservation, stor...
The purpose of this SOP is to describe how to collect, store, and ship tap and drinking water samples for analysis by EPA Method 525.2 (revision 1.0) and EPA method 531.1 (revision 3) for the NHEXAS Arizona project. This SOP provides a brief description of the sample containers,...
Carrasco-Turigas, Glòria; Villanueva, Cristina M.; Goñi, Fernando; Rantakokko, Panu; Nieuwenhuijsen, Mark J.
2013-01-01
Disinfection by-products (DBPs) are ubiquitous contaminants in tap drinking water with the potential to produce adverse health effects. Filtering and boiling tap water can lead to changes in the DBP concentrations and modify the exposure through ingestion. Changes in the concentration of 4 individual trihalomethanes (THM4) (chloroform (TCM), bromodichloromethane (BDCM), dibromochloromethane (DBCM), and bromoform (TBM)), MX, and bromate were tested when boiling and filtering high bromine-containing tap water from Barcelona. For filtering, we used a pitcher-type filter and a household reverse osmosis filter; for boiling, an electric kettle, a saucepan, and a microwave were used. Samples were taken before and after each treatment to determine the change in the DBP concentration. pH, conductivity, and free/total chlorine were also measured. A large decrease of THM4 (from 48% to 97%) and MX concentrations was observed for all experiments. Bromine-containing trihalomethanes were mostly eliminated when filtering while chloroform when boiling. There was a large decrease in the concentration of bromate with reverse osmosis, but there was a little effect in the other experiments. These findings suggest that the exposure to THM4 and MX through ingestion is reduced when using these household appliances, while the decrease of bromate is device dependent. This needs to be considered in the exposure assessment of the epidemiological studies. PMID:23476675
Daily variations in effluent water turbidity and diarrhoeal illness in a Russian city.
Egorov, Andrey I; Naumova, Elena N; Tereschenko, Andrey A; Kislitsin, Victor A; Ford, Timothy E
2003-03-01
To assess an association between temporal variations in drinking water quality and gastrointestinal (GI) illness, a cohort study involving 100 randomly selected families (367 individuals) was conducted in the city of Cherepovets, Russia from June through November 1999. Participants maintained daily diaries of gastrointestinal symptoms, water consumption and other behavioural exposure variables, while daily effluent water quality data were provided by the water utility. The cumulative incidence rate of self-reported gastrointestinal diseases, 1.7 cases per person-year, was almost two orders of magnitude higher than that of officially reported GI infections in the city. An interquartile range increase in effluent water turbidity of 0.8 Nephelometric Turbidity Units was associated with a relative risk of self-reported GI illness of 1.47 (95% Confidence Interval 1.16, 1.86) at a lag of 2 days after control for daily rate of consumption of non-boiled tap water, behavioural covariates, day of the week and a seasonally-related linear trend. In the analysis by subsets of study participants stratified by non-boiled tap water consumption, no statistically significant associations between turbidity and GI illness were found for the study participants who always boiled their drinking water. For individuals who drank non-boiled tap water, statistically significant associations between turbidity and GI illness were detected at lags 1, 2 and 7 days.
Pan, Yang; Zhang, Xiangru; Li, Yu
2016-01-01
Chlorine/chloramine residuals are maintained in drinking water distribution systems to prevent microbial contamination and microorganism regrowth. During household cooking processes (e.g., soup making), the residual chlorine/chloramines in tap water may react with the iodide in iodized table salt to form hypoiodous acid, which could react with remaining natural organic matter in tap water and organic matter in food to generate iodinated disinfection byproducts (I-DBPs). However, I-DBPs formed during cooking with chloraminated/chlorinated tap water are almost completely new to researchers. In this work, by adopting precursor ion scan of m/z 127 using ultra performance liquid chromatography/electrospray ionization-triple quadrupole mass spectrometry, many new polar I-DBPs formed during cooking with chloraminated/chlorinated tap water were detected and proposed with structures, of which 3-iodo-4-hydroxybenzaldehyde, 3-iodo-4-hydroxybenzoic acid, 3-iodo-4-hydroxy-5-methylbenzoic acid, diiodoacetic acid, 3,5-diiodo-4-hydroxybenzaldehyde, 3,5-diiodo-4-hydroxybenzoic acid, 2,6-diiodo-4-nitrophenol, 2,4-diiodo-6-nitrophenol, and 2,4,6-triiodophenol were confirmed with standard compounds. With the aid of ultra fast liquid chromatography/ion trap-time of flight-mass spectrometry, molecular formula identification of five new I-DBPs (C8H5O4I, C7H4NO4I, C8H5O5I, C7H4NO5I, and C8H6O3I2) was achieved. A developmental toxicity with a recently developed sensitive bioassay was conducted for the newly identified I-DBPs, suggesting that phenolic I-DBPs (except for iodinated carboxyphenols) were about 50-200 times more developmentally toxic than aliphatic I-DBPs. The major I-DBPs in a baseline simulated cooking water sample were determined to be from 0.72 to 7.63 μg/L. Polar I-DBPs formed under various disinfection and cooking conditions were compared, and suggestions for controlling their formation were provided. Copyright © 2015 Elsevier Ltd. All rights reserved.
Survey of fluoride levels in vended water stations.
Jadav, Urvi G; Archarya, Bhavini S; Velasquez, Gisela M; Vance, Bradley J; Tate, Robert H; Quock, Ryan L
2014-01-01
This study sought to measure the fluoride concentration of water derived from vended water stations (VWS) and to identify its clinical implications, especially with regard to caries prevention and fluorosis. VWS and corresponding tap water samples were collected from 34 unique postal zip codes; samples were analyzed in duplicate for fluoride concentration. Average fluoride concentration in VWS water was significantly lower than that of tap water (P < 0.001). Fluoride concentration in the VWS water ranged from <0.01 ppm to 0.04 ppm, with a mean concentration of 0.02 ppm (±0.02 ppm). Patients utilizing VWS as their primary source of drinking water may not be receiving optimal caries preventive benefits; thus dietary fluoride supplementation may be indicated. Conversely, to minimize the risk of fluorosis in infants consuming reconstituted infant formula, water from a VWS may be used.
Perfluoroalkyl substances assessment in drinking waters from Brazil, France and Spain.
Schwanz, Thiago G; Llorca, Marta; Farré, Marinella; Barceló, Damià
2016-01-01
Human exposure to perfluoroalkyl substances (PFASs) occurs primarily via dietary intake and drinking water. In this study, 16 PFASs have been assessed in 96 drinking waters (38 bottled waters and 58 samples of tap water) from Brazil, France and Spain. The total daily intake and the risk index (RI) of 16 PFASs through drinking water in Brazil, France and Spain have been estimated. This study was carried out using an analytical method based on an online sample enrichment followed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The quality parameters of the analytical method were satisfactory for the analysis of the 16 selected compounds in drinking waters. Notably, the method limits of detection (MLOD) and method limits of quantification (MLOQ) were in the range of 0.15 to 8.76ng/l and 0.47 to 26.54ng/l, respectively. The results showed that the highest PFASs concentrations were found in tap water samples and the more frequently found compound was perfluorooctanesulfonic acid (PFOS), with mean concentrations of 7.73, 15.33 and 15.83ng/l in French, Spanish and Brazilian samples, respectively. In addition, PFOS was detected in all tap water samples from Brazil. The highest level of PFASs contamination in a single sample was 140.48ng/l in a sample of Spanish tap water. In turn, in bottled waters the highest levels were detected in a French sample with 116ng/l as the sum of PFASs. Furthermore, the most frequent compounds and those at higher concentrations were perfluoroheptanoic acid (PFHpA) with a mean of frequencies in the three countries of 51.3%, followed by perfluorobutanesulfonic acid (PFBS) (27.2%) and perfluorooctanoic acid (PFOA) (23.0%). Considering that bottled water is approximately 38% of the total intake, the total PFASs exposure through drinking water intake for an adult man was estimated to be 54.8, 58.0 and 75.6ng/person per day in Spain, France and Brazil, respectively. However, assuming that the water content in other beverages has at least the same levels of contamination as in bottled drinking water, these amounts were increased to 72.2, 91.4 and 121.0ng/person per day for an adult man in Spain, France and Brazil, respectively. The results of total daily intake in different gender/age groups showed that children are the most exposed population group through hydration with maximum values in Brazil of 2.35 and 2.01ng/kg body weight (BW)/day for male and female, respectively. Finally, the RI was calculated. In spite of the highest values being found in Brazil, it was demonstrated that, in none of the investigated countries, drinking water pose imminent risk associated with PFASs contamination. Copyright © 2015 Elsevier B.V. All rights reserved.
Drinking Water and the Developing Brain.
Silbergeld, Ellen K
2016-01-01
While the problem of unsafe tap water in Flint, Michigan fueled outrage and better awareness in regard to the hazards of lead in tap water, the problem has existed in city after city for years in the US and in other countries. Our author, a winner of the MacArthur Foundation "genius" grant for her work in identifying preventable causes of human disease related to environmental exposures, points out that problems extend well beyond lead. Many potentially harmful contaminants have yet to be evaluated, much less regulated. Her article examines a number of neurotoxins and related issues as they pertain to brain development .
Performance Evaluation of Membrane-Based Septic Tank and Its Reuse Potential for Irrigating Crops.
Khalid, Mehwish; Hashmi, Imran; Khan, Sher Jamal
2017-08-01
Membrane technology, being the most emerging wastewater treatment option, has gained substantial importance with the massive objective of the reuse potential of wastewater. Keeping this in view, the present study was conducted with the rationale to evaluate the performance efficiency of membrane-based septic tank (MBST), and its reuse perspective for irrigating crops. The septic tank was designed by submerging a woven fiber microfiltration membrane module to treat domestic wastewater. Three crops Triticum aestivum (wheat), Coriandrum sativum (coriander), and Mentha arvensis (mint) were selected to be irrigated with treated MBST effluent, untreated wastewater, and tap water (as a control) for comparative growth analysis. Two pathogenic strains, Escherichia coli and Salmonella sp. were selected as reference microbes and their translocation rate was observed in root, shoot, and leaves. Upon maturity, the roots, shoots, and leaves of the above-mentioned plants were aseptically removed for microbiological analysis. Strains were analyzed, using analytical profile index and PCR analysis. Maximum removal efficiencies for MBST in terms of chemical oxygen demand (COD), turbidity, nutrients deduction (phosphorus), and indicator bacteria (Escherichia coli) were found to be 73, 96, 48, and 88%, respectively. Significant bacterial load reduction (p < 0.001) in terms of E. coli (3.8 log CFU/100 mL) and helminths (2 eggs/L) was observed in treated water. High plant yield was observed when irrigated with treated water as compared to tap water, as minimal nutrient removal (48%) was recorded in treated water, with the germination percentage of 88.8%.
... EPA) to set and enforce standards to protect public drinking water systems. The Agency requires water suppliers to produce annual water quality reports. These reports include information about lead amounts. The reports are available to ...
[Investigation of a norovirus outbreak through contaminated centralized water supply system].
Zheng, Hui-Zhen; Guo, Ru-Ning; Li, Jian-Sen; Zhang, Zheng-Min; Li, Hui
2009-07-01
To investigate the etiology and source of an infectious diarrhea outbreak and control the epidemic. Through the retrospective cohort study, we had surveyed all the residents who complained symptoms of diarrhea or vomiting since Nov. 20th,2007 from the five villages in the north of town Y, and collected hygiene information on the water supply system of the five villages, the environment information of three villages and hygiene information of some case-indexed families, and tested the etiological biomarker, including nucleoside acid of norovirus through Real-time PCR and nested PCR technologies. From Nov. 24th to Dec. 3th in 2007, 435 diarrhea or vomiting cases were found in the north of Y town, where tap water A was supplied for daily use. The attack rate was 12.93%. The diarrhea cases were distributed among all country groups who has used tap water A and the attack rate was ranged from 5.21% (20/384) to 21.23% (100/471). Drinking the tap water A was significantly associated with an increased risk of infection (RR = 9.246, 95% CI: 6.25 -13.68). About 85.9% (262/ 305) of the cases were from Nov. 25th to 27th. An investigation of a country of S2 group showed that the incidence of different age groups was distributed as the following: 0 - year-old 20.0% (3/15); 10 - year-old 17.3% (9/52); 20 - year-old 15.2% (16/105); older than 60 year-old 23.3% (7/30). No statistical significance was identified between age and infection(chi2 = 1.15, P >0.05). Most of the patients were not serious and well prognostic, and no hospitalized or dead cases were reported. On site investigation and daily water quality monitoring showed that disinfection procedures were not strictly followed. The monitoring data also indicated the bacteriology index of tap water A was disqualified. The test of Salmonella, Shigella and Staphylococcus aureus were negative in two vomit and one stool samples from patients. Three specimens by Real-time PCR, and six by nested PCR were positive for norovirus among the three feces and three anal swabs samples. With the drinking water sterilization and health education, the epidemic had been controlled rapidly and effectively. The epidemic was a diarrhea outbreak that might be caused by norovirus through drinking the contaminated tap water A.
Giebułtowicz, Joanna; Nałęcz-Jawecki, Grzegorz
2016-04-01
Immunosuppresive therapy following organ transplant frequently includes treatment with tacrolimus and mycophenolic acid derivatives. These pharmaceuticals may enter the environment through wastewater treatment plant (WWTP) effluents and may have a potentially harmful effect on aquatic biota. Tacrolimus, mycophenolic acid and their metabolites were measured at specific points of a large Polish river (Vistula), a smaller river (Utrata) and in tap water samples from the Warsaw region. Analysis was performed using liquid chromatography tandem mass spectrometry, after solid phase extraction for water samples, or QuEChERS extraction for sediments. Residues of tacrolimus were below quantitation limits in both water and sediment samples. However, in water samples mycophenolic acid concentrations were measured at up to 180 ng L(-1) downstream of WWTP outfalls. No immunosuppressive drugs were detected in tap water. Concentrations of mycophenolic acid exceeded the predicted no effect concentration (PNEC) value in some Polish surface water, and risk calculations predicted at least twice higher concentrations in some other countries of the European Union. To the best of the authors' knowledge, this is the first report of these immunosuppressive drug concentrations in the environment. Copyright © 2016 Elsevier Ltd. All rights reserved.
Effect of decaffeination of coffee or tea on gastro-oesophageal reflux.
Wendl, B; Pfeiffer, A; Pehl, C; Schmidt, T; Kaess, H
1994-06-01
Coffee and tea are believed to cause gastro-oesophageal reflux; however, the effects of these beverages and of their major component, caffeine, have not been quantified. The aim of this study was to evaluate gastro-oesophageal reflux induced by coffee and tea before and after a decaffeination process, and to compare it with water and water-containing caffeine. Three-hour ambulatory pH-metry was performed on 16 healthy volunteers, who received 300 ml of (i) regular coffee, decaffeinated coffee or tap water (n = 16), (ii) normal tea, decaffeinated tea, tap water, or coffee adapted to normal tea in caffeine concentration (n = 6), and (iii) caffeine-free and caffeine-containing water (n = 8) together with a standardized breakfast. Regular coffee induced a significant (P < 0.05) gastro-oesophageal reflux compared with tap water and normal tea, which were not different from each other. Decaffeination of coffee significantly (P < 0.05) diminished gastro-oesophageal reflux, whereas decaffeination of tea or addition of caffeine to water had no effect. Coffee adapted to normal tea in caffeine concentration significantly (P < 0.05) increased gastro-oesophageal reflux. Coffee, in contrast to tea, increases gastro-oesophageal reflux, an effect that is less pronounced after decaffeination. Caffeine does not seem to be responsible for gastro-oesophageal reflux which must be attributed to other components of coffee.
Diversity and antibiotic resistance patterns of Sphingomonadaceae isolates from drinking water.
Vaz-Moreira, Ivone; Nunes, Olga C; Manaia, Célia M
2011-08-15
Sphingomonadaceae (n = 86) were isolated from a drinking water treatment plant (n = 6), tap water (n = 55), cup fillers for dental chairs (n = 21), and a water demineralization filter (n = 4). The bacterial isolates were identified based on analysis of the 16S rRNA gene sequence, and intraspecies variation was assessed on the basis of atpD gene sequence analysis. The isolates were identified as members of the genera Sphingomonas (n = 27), Sphingobium (n = 28), Novosphingobium (n = 12), Sphingopyxis (n = 7), and Blastomonas (n = 12). The patterns of susceptibility to five classes of antibiotics were analyzed and compared for the different sites of isolation and taxonomic groups. Colistin resistance was observed to be intrinsic (92%). The highest antibiotic resistance prevalence values were observed in members of the genera Sphingomonas and Sphingobium and for beta-lactams, ciprofloxacin, and cotrimoxazole. In tap water and in water from dental chairs, antibiotic resistance was more prevalent than in the other samples, mainly due to the predominance of isolates of the genera Sphingomonas and Sphingobium. These two genera presented distinct patterns of association with antibiotic resistance, suggesting different paths of resistance development. Antibiotic resistance patterns were often related to the species rather than to the site or strain, suggesting the importance of vertical resistance transmission in these bacteria. This is the first study demonstrating that members of the family Sphingomonadaceae are potential reservoirs of antibiotic resistance in drinking water.
Ji, Pan; Rhoads, William J; Edwards, Marc A; Pruden, Amy
2017-01-01
Hot water plumbing is an important conduit of microbes into the indoor environment and can increase risk of opportunistic pathogens (for example, Legionella pneumophila). We examined the combined effects of water heater temperature (39, 42, 48, 51 and 58 °C), pipe orientation (upward/downward), and water use frequency (21, 3 and 1 flush per week) on the microbial composition at the tap using a pilot-scale pipe rig. 16S rRNA gene amplicon sequencing indicated that bulk water and corresponding biofilm typically had distinct taxonomic compositions (R2Adonis=0.246, PAdonis=0.001), yet similar predicted functions based on PICRUSt analysis (R2Adonis=0.087, PAdonis=0.001). Although a prior study had identified 51 °C under low water use frequency to enrich Legionella at the tap, here we reveal that 51 °C is also a threshold above which there are marked effects of the combined influences of temperature, pipe orientation, and use frequency on taxonomic and functional composition. A positive association was noted between relative abundances of Legionella and mitochondrial DNA of Vermamoeba, a genus of amoebae that can enhance virulence and facilitate replication of some pathogens. This study takes a step towards intentional control of the plumbing microbiome and highlights the importance of microbial ecology in governing pathogen proliferation. PMID:28282040
40 CFR 60.143 - Monitoring of operations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... steel production cycle, and the time and duration of any diversion of exhaust gases from the main stack... sensor or pressure tap must be located close to the water discharge point. The Administrator must be consulted for approval in advance of selecting alternative locations for the pressure sensor or tap. (3) All...
40 CFR 60.143 - Monitoring of operations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... steel production cycle, and the time and duration of any diversion of exhaust gases from the main stack... sensor or pressure tap must be located close to the water discharge point. The Administrator must be consulted for approval in advance of selecting alternative locations for the pressure sensor or tap. (3) All...
20 CFR 1001.151 - Other funding criteria.
Code of Federal Regulations, 2010 CFR
2010-04-01
... allocation will be available for distribution based on Transition Assistance Program (TAP) workload and other exigencies. (b) Funding for TAP workshops will be allocated on a per workshop basis. Funding to the States... for TAP workshops, will be allocated based on need. ...
Jagals, P
2006-01-01
The concept of safe water is defined by three principles: the health-related quality must be suitable, the supply/source must be accessible and the water must constantly be available in quantities sufficient for the intended use. If any one (or more) of these three elements is missing from a water services improvement programme, providing safe water is not successfully achieved. A study in a deep rural area in South Africa showed that providing small communities, using untreated river water as their only water source, with good quality water through a piped distribution system and accessible at communal taps did not fall within our parameters of safe water. The parameters for measuring the three principles were: absence of Escherichia coli in drinking water samples; accessibility by improving tap distances to within 200 m from each household; availability by assessing whether households have at least 25 L per person per day. Results show that although E. coli levels were reduced significantly, households were still consuming water with E. coli numbers at non-compliant levels. Access (distance) was improved from an average of 750 m from households to river source to an average of 120 m to new on-tap source points. This did not result in significant increases in household quantities, which on average remained around 18 L per person per day.
Feng, Yaoyu; Zhao, Xukun; Chen, Jiaxu; Jin, Wei; Zhou, Xiaonong; Li, Na; Wang, Lin; Xiao, Lihua
2011-01-01
Genotyping studies on the source and human infection potential of Cryptosporidium oocysts in water have been almost exclusively conducted in industrialized nations. In this study, 50 source water samples and 30 tap water samples were collected in Shanghai, China, and analyzed by the U.S. Environmental Protection Agency (EPA) Method 1623. To find a cost-effective method to replace the filtration procedure, the water samples were also concentrated by calcium carbonate flocculation (CCF). Of the 50 source water samples, 32% were positive for Cryptosporidium and 18% for Giardia by Method 1623, whereas 22% were positive for Cryptosporidium and 10% for Giardia by microscopy of CCF concentrates. When CCF was combined with PCR for detection, the occurrence of Cryptosporidium (28%) was similar to that obtained by Method 1623. Genotyping of Cryptosporidium in 17 water samples identified the presence of C. andersoni in 14 water samples, C. suis in 7 water samples, C. baileyi in 2 water samples, C. meleagridis in 1 water sample, and C. hominis in 1 water sample. Therefore, farm animals, especially cattle and pigs, were the major sources of water contamination in Shanghai source water, and most oocysts found in source water in the area were not infectious to humans. Cryptosporidium oocysts were found in 2 of 30 tap water samples. The combined use of CCF for concentration and PCR for detection and genotyping provides a less expensive alternative to filtration and fluorescence microscopy for accurate assessment of Cryptosporidium contamination in water, although the results from this method are semiquantitative. PMID:21498768
NASA Astrophysics Data System (ADS)
Vargas, A. I.; Schaffer, B.; Yuhong, L.; Sternberg, L. O.
2016-12-01
Stable oxygen (δ18O) and hydrogen (δ2H) isotope composition of precipitation, soil and plants have been studied over the years to understand the mechanism of soil water movement and the depth of plant water uptake in the soil water profile. Recent studies have suggested that in soil during the wet season, tightly bound water does not mix with mobile water but is retained in the soil until the dry season when it is taken up by plants via the force of transpiration. To test this, we sampled δ18O and δ2H in plant stems as a proxy for wet season mobile water and dry season bound water in two types of soils to determine if mixing occurs between mobile and tightly bound soil water. Plastic pots were filled with clay or very gravelly loam soil and a Persea americana tree was planted in each pot. Soil in each pot was first saturated with tap water to fully label the bound water with the isotopic identity of tap water and then fully saturated with either tap water (T) or isotopically-enriched pool water (P) and covered with white polyethylene to prevent evaporation. After saturating the soil, δ18O and δ2H of water draining from each pot were similar to those of water added to each pot for both the T and P treatments. For each treatment, δ18O and δ2H in plant stems were sampled 2-3 days after soil was initially saturated (simulated wet season; soil tension < 0.10 kPa) representing the mobile water and again 7-9 days after soil was saturated representing the bound water (simulated dry season; soil tension > 80.0 kPa). During the "dry season", there was a significant difference between T and P treatments for δ18O and δ2H in plant stems, indicating that bound water accessed by plants in the P treatment did not retain the tap water label and mixing occurred between mobile and bound water in the soil. Comparing P-T in the wet season with P-T in the dry season indicated that as much as 95% of water freely exchanged between the mobile and bound components of the soil. This is contrary to recent studies suggesting that no mixing occurs.
Tipple, Brett J; Jameel, Yusuf; Chau, Thuan H; Mancuso, Christy J; Bowen, Gabriel J; Dufour, Alexis; Chesson, Lesley A; Ehleringer, James R
2017-08-01
Water availability and sustainability in the Western United States is a major flashpoint among expanding communities, growing industries, and productive agricultural lands. This issue came to a head in 2015 in the State of California, when the State mandated a 25% reduction in urban water use following a multi-year drought that significantly depleted water resources. Water demands and challenges in supplying water are only expected to intensify as climate perturbations, such as the 2012-2015 California Drought, become more common. As a consequence, there is an increased need to understand linkages between urban centers, water transport and usage, and the impacts of climate change on water resources. To assess if stable hydrogen and oxygen isotope ratios could increase the understanding of these relationships within a megalopolis in the Western United States, we collected and analyzed 723 tap waters across the San Francisco Bay Area during seven collection campaigns spanning 21 months during 2013-2015. The San Francisco Bay Area was selected as it has well-characterized water management strategies and the 2012-2105 California Drought dramatically affected its water resources. Consistent with known water management strategies and previously collected isotope data, we found large spatiotemporal variations in the δ 2 H and δ 18 O values of tap waters within the Bay Area. This is indicative of complex water transport systems and varying municipality-scale management decisions. We observed δ 2 H and δ 18 O values of tap water consistent with waters originating from snowmelt from the Sierra Nevada Mountains, local precipitation, ground water, and partially evaporated reservoir sources. A cluster analysis of the isotope data collected in this study grouped waters from 43 static sampling sites that were associated with specific water utility providers within the San Francisco Bay Area and known management practices. Various management responses to the drought, such as source switching, bringing in new sources, and water conservation, were observed in the isotope data. Finally, we estimated evaporative loss from one utility's reservoir system during the 2015 water year using a modified Craig-Gordon model to estimate the consequences of the drought on this resource. We estimated that upwards of 6.6% of the water in this reservoir system was lost to evaporation. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Crawford, Frank S.
1982-05-01
The ''hot chocolate effect'' was investigated quantitatively, using water. If a tall glass cylinder is filled nearly completely with water and tapped on the bottom with a softened mallet one can detect the lowest longitudinal mode of the water column, for which the height of the water column is one-quarter wavelength. If the cylinder is rapidly filled with hot tap water containing dissolved air the pitch of that mode may descend by nearly three octaves during the first few seconds as the air comes out of solution and forms bubbles. Then the pitch gradually rises as the bubbles float to the top. A simple theoretical expression for the pitch ratio is derived and compared with experiment. The agreement is good to within the 10% accuracy of the experiments.
Lloret, Juan; Sancho, Juan; Pu, Minhao; Gasulla, Ivana; Yvind, Kresten; Sales, Salvador; Capmany, José
2011-06-20
A complex-valued multi-tap tunable microwave photonic filter based on single silicon-on-insulator microring resonator is presented. The degree of tunability of the approach involving two, three and four taps is theoretical and experimentally characterized, respectively. The constraints of exploiting the optical phase transfer function of a microring resonator aiming at implementing complex-valued multi-tap filtering schemes are also reported. The trade-off between the degree of tunability without changing the free spectral range and the number of taps is studied in-depth. Different window based scenarios are evaluated for improving the filter performance in terms of the side-lobe level.
NASA Astrophysics Data System (ADS)
Kennedy, C. D.; Bowen, G. J.; Ehleringer, J. R.
2008-12-01
Stable isotope ratios of hydrogen and oxygen (δ2H and δ18O) are environmental forensic tracers that can be used to constrain the origin and movement of animals, people, and products. The fundamental assumption underlying this method is that water resources at different geographic locations have distinct and characteristic isotopic signatures that are assimilated into organic tissues. Although much is known about regional-scale spatio-temporal variability in δ2H and δ18O of water, few studies have addressed the question of how distinct these geographic and seasonal patterns are for any given site. To address this question, a 2-year survey of δ2H and δ18O in tap water from across the contiguous U.S. and Canada was conducted. The data show that seasonal variability in δ2H and δ18O of tap water is generally low (<10 ‰ for δ2H), and those with the highest variability can be classified as: a) cities or towns in areas of high climate seasonality, or b) large cities in arid or seasonally arid regions which access and switch among multiple water sources throughout the year. The data suggest that inter-annual variation in tap water isotope ratios is typically low, with a median difference for month-month pairs during the 2 sampling years of 2.7 (δ2H). The results from this study confirm the existence of temporal variability in δ2H and δ18O of tap water, but suggest that this variability in human-managed systems is highly damped and may be amenable to classification, modeling, and prediction. In all, the data provide the foundation for incorporating temporal variation in predictive models of water and organic δ2H and δ18O, leading to more robust and statistically defensible tests of geographic origin.
Drinking water disinfection by-products and time to pregnancy.
MacLehose, Richard F; Savitz, David A; Herring, Amy H; Hartmann, Katherine E; Singer, Philip C; Weinberg, Howard S
2008-05-01
Laboratory evidence suggests tap water disinfection by-products (DBPs) could have an effect very early in pregnancy, typically before clinical detectability. Undetected early losses would be expected to increase the reported number of cycles to clinical pregnancy. We investigated the association between specific DBPs (trihalomethanes, haloacetic acids, brominated-trihalomethanes, brominated-haloacetic acids, total organic halides, and bromodichloromethane) and time to pregnancy among women who enrolled in a study of drinking water and reproductive outcomes. We quantified exposure to DBPs through concentrations in tap water, quantity ingested through drinking, quantity inhaled or absorbed while showering or bathing, and total integrated exposure. The effect of DBPs on time to pregnancy was estimated using a discrete time hazard model. Overall, we found no evidence of an increased time to pregnancy among women who were exposed to higher levels of DBPs. A modestly decreased time to pregnancy (ie, increased fecundability) was seen among those exposed to the highest level of ingested DBPs, but not for tap water concentration, the amount absorbed while showering or bathing, or the integrated exposure. Our findings extend those of a recently published study suggesting a lack of association between DBPs and pregnancy loss.
Waterborne disease outbreak detection: an integrated approach using health administrative databases.
Coly, S; Vincent, N; Vaissiere, E; Charras-Garrido, M; Gallay, A; Ducrot, C; Mouly, D
2017-08-01
Hundreds of waterborne disease outbreaks (WBDO) of acute gastroenteritis (AGI) due to contaminated tap water are reported in developed countries each year. Such outbreaks are probably under-detected. The aim of our study was to develop an integrated approach to detect and study clusters of AGI in geographical areas with homogeneous exposure to drinking water. Data for the number of AGI cases are available at the municipality level while exposure to tap water depends on drinking water networks (DWN). These two geographical units do not systematically overlap. This study proposed to develop an algorithm which would match the most relevant grouping of municipalities with a specific DWN, in order that tap water exposure can be taken into account when investigating future disease outbreaks. A space-time detection method was applied to the grouping of municipalities. Seven hundred and fourteen new geographical areas (groupings of municipalities) were obtained compared with the 1,310 municipalities and the 1,706 DWN. Eleven potential WBDO were identified in these groupings of municipalities. For ten of them, additional environmental investigations identified at least one event that could have caused microbiological contamination of DWN in the days previous to the occurrence of a reported WBDO.
Moslemi, Mohammad Kazem; Saghafi, Hossein; Joorabchin, Seyed Mohammad Amin
2011-01-01
Purpose The aim of this study was to evaluate the biochemical stone composition in general population of Qom province, central Iran, and its relationship with high tap water hardness. Materials and methods In a prospective study, from March 2008 to July 2011, biochemical analysis of urinary stones in patients living in Qom province for at least 5 years was performed. Stones were retrieved by spontaneous passage, endoscopic or open surgery, and after extracorporeal shockwave lithotripsy. Demographic findings and the drinking water supply of patients were evaluated and compared with biochemical stone analysis. Results Stone analysis was performed in 255 patients. The most dominant composition of urinary stones was calcium oxalate (73%), followed by uric acid (24%), ammonium urate (2%), and cystine (1%). The peak incidence of urinary stone was in patients in their forties. Overall male to female ratio was 4.93:1. Conclusion The dominant stone composition in inhabitants of central Iran, where tap water hardness is high, was calcium oxalate stones. On the basis of this study, biochemical urinary stone composition of Qom does not differ from other regions of Iran with lower water hardness. PMID:22163171
Fomete, B; Saheeb, B D; Obiadazie, A C
2015-06-01
Post operative care of sutured wound is important after surgery. Sutured wounds within the oral cavity are kept clean through frequent rinses with either normal saline, chlorhexidine mouth rinses, hydrogen peroxide diluted with saline, or fresh tap water. The patients were randomised into 3 groups (A, B and C). The container used had 34 chlorhexidine, 34 warm saline and 32 warm water mouth rinses. The latter served as control. All selected patients had scaling and polishing done preoperatively when needed. All participants in each group did not receive antibiotics but received analgesics (paracetamol 1 g 8 h for 5 days,). There were 49 females and 51 males, in the age range between 18 and 50 years. Microorganisms were found to grow on sutures with streptococcus viridians predominating followed by staphylococcus epidermides. The effects of chlorhexidine, warm saline and warm tap water mouth washes were not statistically significant. Chlorhexidine, warm salt water and warm tap water averagely produced the same number of colony forming units of bacteria, which shows that the three different mouth washes are equally effective as post-operative mouth rinses after oral surgery.
Chen, Zhi; Chen, Jiayun; Pan, Dong; Li, Hongwei; Yao, Yunhui; Lyu, Zu; Yang, Liting; Ma, Li-Jun
2017-03-01
A new rhodamine B-based "reactive" optical sensor (1) for Hg 2+ was synthesized. Sensor 1 shows a unique colorimetric and fluorescent "turn-on" selectivity to Hg 2+ over 14 other metal ions with a hypersensitivity (detection limits are 27.6 nM (5.5 ppb) and 6.9 nM (1.4 ppb), respectively) in neutral buffer solution. To test its applicability in the environment, sensor 1 was applied to quantify and visualize low levels of Hg 2+ in tap water and river water samples. The results indicate sensor 1 is a highly sensitive fluorescent sensor for Hg 2+ with a detection limit of 1.7 ppb in tap water and river water. Moreover, sensor 1 is a convenient visualizing sensor for low levels of Hg 2+ (0.1 ppm) in water environment (from colorless to light pink). In addition, sensor 1 shows good potential as a fluorescent visualizing sensor for Hg 2+ in fetal bovine serum and living 293T cells. The results indicate that sensor 1 shows good potential as a highly sensitive sensor for the detection of Hg 2+ in environmental and biological samples. Graphical Abstract A new rhodamine B-based "reactive" optical sensor (1) for Hg 2+ was synthesized. 1 shows a unique colorimetric and fluorescent "turn-on" selectivity to Hg 2+ over 14 other metal ions with a hypersensitivity in water environment. And it is a convenient visualizing probe for low levels of Hg 2+ in environment aqueous media, fetal bovine serum and living 293T cells.
Optimization of adenovirus 40 and 41 recovery from tap water using small disk filters.
McMinn, Brian R
2013-11-01
Currently, the U.S. Environmental Protection Agency's Information Collection Rule (ICR) for the primary concentration of viruses from drinking and surface waters uses the 1MDS filter, but a more cost effective option, the NanoCeram® filter, has been shown to recover comparable levels of enterovirus and norovirus from both matrices. In order to achieve the highest viral recoveries, filtration methods require the identification of optimal concentration conditions that are unique for each virus type. This study evaluated the effectiveness of 1MDS and NanoCeram filters in recovering adenovirus (AdV) 40 and 41 from tap water, and optimized two secondary concentration procedures the celite and organic flocculation method. Adjustments in pH were made to both virus elution solutions and sample matrices to determine which resulted in higher virus recovery. Samples were analyzed by quantitative PCR (qPCR) and Most Probable Number (MPN) techniques and AdV recoveries were determined by comparing levels of virus in sample concentrates to that in the initial input. The recovery of adenovirus was highest for samples in unconditioned tap water (pH 8) using the 1MDS filter and celite for secondary concentration. Elution buffer containing 0.1% sodium polyphosphate at pH 10.0 was determined to be most effective overall for both AdV types. Under these conditions, the average recovery for AdV40 and 41 was 49% and 60%, respectively. By optimizing secondary elution steps, AdV recovery from tap water could be improved at least two-fold compared to the currently used methodology. Identification of the optimal concentration conditions for human AdV (HAdV) is important for timely and sensitive detection of these viruses from both surface and drinking waters. Published by Elsevier B.V.
Cytometric Approach for Detection of Encephalitozoon intestinalis, an Emergent Agent▿
Barbosa, Joana; Rodrigues, Acácio Gonçalves; Pina-Vaz, Cidália
2009-01-01
Encephalitozoon intestinalis is responsible for intestinal disease in patients with AIDS and immunocompetent patients. The infectious form is a small spore that is resistant to water treatment procedures. Its detection is very important, but detection is very cumbersome and time-consuming. Our main objective was to develop and optimize a specific flow cytometric (FC) protocol for the detection of E. intestinalis in hospital tap water and human feces. To determine the optimal specific antibody (Microspor-FA) concentration, a known concentration of E. intestinalis spores (Waterborne, Inc.) was suspended in hospital tap water and stool specimens with different concentrations of Microspor-FA, and the tap water and stool specimens were incubated under different conditions. The sensitivity limit and specificity were also evaluated. To study spore infectivity, double staining with propidium iodide (PI) and Microspor-FA was undertaken. Distinct approaches for filtration and centrifugation of the stool specimens were used. E. intestinalis spores stained with 10 μg/ml of Microspor-FA at 25°C overnight provided the best results. The detection limit was 5 × 104 spores/ml, and good specificity was demonstrated. Simultaneous staining with Microspor-FA and PI ensured that the E. intestinalis spores were dead and therefore noninfectious. With the stool specimens, better spore recovery was observed with a saturated solution of NaCl and centrifugation at 1,500 × g for 15 min. A new approach for the detection of E. intestinalis from tap water or human feces that ensures that the spores are not viable is now available and represents an important step for the prevention of this threat to public health. PMID:19439525
REGULATED CONTAMINANTS IN DRINKING WATER
Safe drinking water is critical to protecting human health. More than 260 million Americans rely on the safety of tap water provided by water systems that comply with national drinking water standards. EPA's strategy for ensuring safe drinking water includes four key elements, ...
Wang, Hexing; Wang, Na; Wang, Bin; Zhao, Qi; Fang, Hong; Fu, Chaowei; Tang, Chuanxi; Jiang, Feng; Zhou, Ying; Chen, Yue; Jiang, Qingwu
2016-03-01
A variety of antibiotics have been found in aquatic environments, but antibiotics in drinking water and their contribution to antibiotic exposure in human are not well-explored. For this, representative drinking water samples and 530 urine samples from schoolchildren were selected in Shanghai, and 21 common antibiotics (five macrolides, two β-lactams, three tetracyclines, four fluoquinolones, four sulfonamides, and three phenicols) were measured in water samples and urines by isotope dilution two-dimensional ultraperformance liquid chromatography coupled with high-resolution quadrupole time-of-flight mass spectrometry. Drinking water included 46 terminal tap water samples from different spots in the distribution system of the city, 45 bottled water samples from 14 common brands, and eight barreled water samples of different brands. Of 21 antibiotics, only florfenicol and thiamphenicol were found in tap water, with the median concentrations of 0.0089 ng/mL and 0.0064 ng/mL, respectively; only florfenicol was found in three bottled water samples from a same brand, with the concentrations ranging from 0.00060 to 0.0010 ng/mL; no antibiotics were found in barreled water. In contrast, besides florfenicol and thiamphenicol, an additional 17 antibiotics were detected in urine samples, and the total daily exposure doses and detection frequencies of florfenicol and thiamphenicol based on urine samples were significantly and substantially higher than their predicted daily exposure doses and detection frequencies from drinking water by Monte Carlo Simulation. These data indicated that drinking water was contaminated by some antibiotics in Shanghai, but played a limited role in antibiotic exposure of children.
Watanabe, Yuko; Kimura, Kenji; Yang, Cheng-Hsiung; Ooi, Hong-Kean
2005-12-01
A survey on the presence of Cryptosporidium oocyst and Giardia cyst in livestock drinking water as well as the urban tap water throughout Taiwan was carried out. Water examination for the presence of the protozoa was conducted by filtering through a PTFE membrane followed by immunomagnetic separation (IMS) and immunostaining the sediment with commercially available monoclonal antibody against Cryptosporidium and Giardia. Of the 55 different water samples from various sources examined, 2 were found to contain both of Cryptosporidium oocyst and Giardia cyst, 1 was found to contain Cryptosporidium oocyst only. These protozoa-positive water samples, originating from underground well and from the mountain spring, were also used as drinking water for livestock. However, no Cryptosporidium oocyst was found in the city tap water. This is the first report of Cryptosporidium oocyst and Giardia cyst being found in the drinking water for livestock.
... Guidelines Wash your hands. Make the nasal wash solution. Do not use tap water for the nasal ... Whichever water you use to make the saline solution, replace container or water at least weekly. To ...
Ground-water conditions in Georgia, 1997
Cressler, A.M.
1998-01-01
Ground-water conditions in Georgia during 1997 and for the period of record were evaluated using data from ground-water-level and ground-water-quality monitoring networks. Data for 1997 included in this report are from continuous water-level records from 71 wells and chloride analyses from 14 wells. In 1997, annual mean ground-water levels in Georgia ranged from 6.2 feet (ft) lower to 5.6 ft higher than in 1996. Of the 71 wells summarized in this report, 23 wells had annual mean water levels that were higher, 35 wells had annual mean water levels that were lower, and 11 wells had annual mean water levels that were about the same in 1997 as during 1996. Data for two wells are incomplete because data collection was discontinued at one well, and the equipment was vandalized at one well. Record-low daily mean water levels were recorded in six wells tapping the Upper Floridan aquifer, one well tapping the Caliborne aquifer, two wells tapping the Clayton aquifer, and three wells tapping Cretaceous aquifers. These record lows were from 0.2 to 5.6 ft lower than previous record lows. Chloride concentration in water from the Upper Floridan aquifer in most of coastal Georgia was within drinking-water standards established by the Georgia Department of Natural Resources and the U.S. Environmental Protection Agency. In the Savannah area, chloride concentration has not changed appreciably with time. However, chloride concentration in water from some wells that tap the Floridan aquifer system in the Brunswick area exceeds the drinking-water standard. Ground-water-level and ground-water-quality data are essential for water assessment and management. Ground-water-level fluctuations and trends can be used to estimate changes in aquifer storage resulting from the effects of ground-water withdrawal and recharge from precipitation. These data can be used to address water-management needs and to evaluate the effects of management and conservation programs. As part of the ground-water investigations conducted by the U.S. Geological Survey (USGS), in cooperation with the State of Georgia and city and county governments, a Statewide water-level- measurement program was started in 1938. Initially, this program consisted of an observation-well network in the coastal area of Georgia to monitor variations in ground- water storage and quality. Additional wells were later included in areas where data could be used to predict potential water-resource problems. During 1997, periodic water-level measurements were made in 67 wells, and continuous water-level measurements were obtained from 151 wells. Continuous water-level records were obtained using analog (pen and chart) recorders, digital recorders that record the water level at 30-minute or 60-minute intervals, and electronic data recorders that record the water level at 60-minute intervals. For wells having incomplete water-level record, water levels during periods of missing record may have been higher or lower than recorded water levels. Water samples collected from 23 wells during April and November 1997 were analyzed to determine chloride concentration in the Savannah and Brunswick areas.
Moazami, Fariborz; Mirhadi, Hosein; Geramizadeh, Bita; Sahebi, Safoura
2012-04-01
The purpose of this study was to evaluate the ability of soymilk, powdered milk, and Hank's balanced salt solution (HBSS) to maintain human periodontal ligament (PDL) cell viability in vitro. PDL cells were obtained from extracted healthy third molars and cultured in Dulbecco's modified Eagles medium (DMEM). The cultures were exposed for 1, 2, 4, and 8 h to experimental solutions (tap water served as negative control and DMEM as positive control) at 37°C. The viable cells were then counted using the trypan blue exclusion technique. Data were analyzed by using one-way anova, post hoc Scheffe and two-way anova test. Statistical analysis showed that HBSS, powdered baby formula, and soymilk maintain cell viability equally well in different periods of times. Tap water cannot keep cells viable as well as other solutions. Soymilk and powdered baby formula can be recommended as suitable storage media for avulsed teeth for up to 8 h. © 2011 John Wiley & Sons A/S.
ERIC Educational Resources Information Center
Wheeler, Andrew P. S.
2012-01-01
This article aims to describe how to visualize surface tension effects in liquid jets. A simple experiment is proposed using the liquid jet flow from a mains water tap/faucet. Using a modern digital camera with a high shutter speed, it is possible to visualize the instabilities (capillary waves) that form within the jet due to the action of…
Low Contribution of PbO2-Coated Lead Service Lines to Water Lead Contamination at the Tap
To determine if field experience corroborates that formation of stable PbO2 coatings on lead service lines (LSLs) provides an effective lead contamination control strategy, lead profile sampling was undertaken at eight home kitchen taps in three US cities (Newport, Rhode Island; ...
Surgical scrubbing: can we clean up our carbon footprints by washing our hands?
Somner, J E A; Stone, N; Koukkoulli, A; Scott, K M; Field, A R; Zygmunt, J
2008-11-01
A growing scientific consensus states that the global climate is changing and that human activity is responsible for these changes. It folLows that each of us has a responsibility to look at how our own lives impact on the environment. This study aimed to investigate water use during surgical scrubbing. Two water delivery systems were assessed to see whether technological innovation can promote more 'environmentally friendly' scrubbing behaviour. At least 10 different individuals, comprising surgeons, assistants and scrub nurses, were observed at two sites. Twenty-five separate surgical scrubs were observed in each location and the length of time for which the tap was on recorded. The tap was on during surgical scrubbing for a mean of 2 min 23 s at Gartnavel General Hospital (maximum: 4 min 37 s; minimum: 49 s; SD: 55 s) and for a mean of 1 min 7 s at Stobhill Hospital (maximum: 2 min 25 s; minimum: 19 s; SD: 33 s). The mean 'tap on' time (in seconds) at Gartnavel was significantly greater than that at Stobhill [t(39.5)=P<0.001]. A different tap design resulted in a net saving of 5.7 L of hot water, approximately 600 kJ of energy and 80 g of carbon dioxide emitted per surgical scrub. Surgical scrubbing is a ubiquitous procedure performed daily in healthcare settings. A simple technological solution can reduce water and energy use by modifying hand-washing behaviour and thereby reduce the carbon footprint of surgical scrubbing.
Zhou, Xuefeng; Hu, Chun; Hu, Xuexiang; Peng, Tianwei
2012-06-15
Ag-AgBr was deposited onto mesoporous alumina (MA) and titanium-doped MA by a deposition-precipitation method. The photocatalytic activity and the dissolution of Ag(+) from different catalysts were investigated during the photodegradation of 2-chlorophenol (2-CP) and phenol in ultrapure water and tap water with visible-light irradiation. With the increase in doped titanium, the Ag(+) dissolution decreased with a decrease in the photocatalytic activity. Ag-AgBr/MA-Ti1 was considered the better catalyst for practical applications because its Ag(+) dissolution was minimal (0.4 mg L(-1) in ultrapure water and 5 μg L(-1) in tap water), although its photoactivity was slightly less than that of Ag-AgBr/MA. The dissolution of Ag(+) was related to a charge-transfer process based on the study of cyclic voltammetry analyses under a variety of experimental conditions. The results suggested that several types of anions in the water, including CO(3)(2-), SO(4)(2-), and Cl(-), could act as electron donors that trap the photogenerated holes on Ag nanoparticles to facilitate electron circulation; this would decrease the release of Ag(+). Our studies indicated that the catalyst had a higher activity and stability in water purification. Copyright © 2012. Published by Elsevier B.V.
Exposure assessment of radon in the drinking water supplies: a descriptive study in Palestine
2012-01-01
Background Radon gas is considered as a main risk factor for lung cancer and found naturally in rock, soil, and water. The objective of this study was to determine the radon level in the drinking water sources in Nablus city in order to set up a sound policy on water management in Palestine. Methods This was a descriptive study carried out in two phases with a random sampling technique in the second phase. Primarily, samples were taken from 4 wells and 5 springs that supplied Nablus city residents. For each source, 3 samples were taken and each was analyzed in 4 cycles by RAD 7 device manufactured by Durridge Company. Secondly, from the seven regions of the Nablus city, three samples were taken from the residential tap water of each region. Regarding the old city, ten samples were taken. Finally, the mean radon concentration value for each source was calculated. Results The mean (range) concentration of radon in the main sources were 6.9 (1.5-23.4) Becquerel/liter (Bq/L). Separately, springs and wells' means were 4.6 Bq/L and 9.5 Bq/L; respectively. For the residential tap water in the 7 regions, the results of the mean (range) concentration values were found to be 1.0 (0.9-1.3) Bq/L. For the old city, the mean (range) concentration values were 2.3 (0.9-3.9) Bq/L. Conclusions Except for Al-Badan well, radon concentrations in the wells and springs were below the United State Environmental Protection Agency maximum contaminated level (U.S EPA MCL). The level was much lower for tap water. Although the concentration of radon in the tap water of old city were below the MCL, it was higher than other regions in the city. Preventive measures and population awareness on radon's exposure are recommended. PMID:22243625
Exposure assessment of radon in the drinking water supplies: a descriptive study in Palestine.
Al Zabadi, Hamzeh; Musmar, Samar; Issa, Shaza; Dwaikat, Nidal; Saffarini, Ghassan
2012-01-13
Radon gas is considered as a main risk factor for lung cancer and found naturally in rock, soil, and water. The objective of this study was to determine the radon level in the drinking water sources in Nablus city in order to set up a sound policy on water management in Palestine. This was a descriptive study carried out in two phases with a random sampling technique in the second phase. Primarily, samples were taken from 4 wells and 5 springs that supplied Nablus city residents. For each source, 3 samples were taken and each was analyzed in 4 cycles by RAD 7 device manufactured by Durridge Company. Secondly, from the seven regions of the Nablus city, three samples were taken from the residential tap water of each region. Regarding the old city, ten samples were taken. Finally, the mean radon concentration value for each source was calculated. The mean (range) concentration of radon in the main sources were 6.9 (1.5-23.4) Becquerel/liter (Bq/L). Separately, springs and wells' means were 4.6 Bq/L and 9.5 Bq/L; respectively. For the residential tap water in the 7 regions, the results of the mean (range) concentration values were found to be 1.0 (0.9-1.3) Bq/L. For the old city, the mean (range) concentration values were 2.3 (0.9-3.9) Bq/L. Except for Al-Badan well, radon concentrations in the wells and springs were below the United State Environmental Protection Agency maximum contaminated level (U.S EPA MCL). The level was much lower for tap water. Although the concentration of radon in the tap water of old city were below the MCL, it was higher than other regions in the city. Preventive measures and population awareness on radon's exposure are recommended.
Luo, Qian; Wang, Donghong; Wang, Zijian
2012-10-15
An investigation of the occurrence of nine nitrosamines in drinking water following different water treatment processes was conducted using samples from seven drinking water treatment plants in three cities and tap waters in one city in China. The total nitrosamine levels ranged from not detected (n.d.) to 43.45 ng/L. The species and concentrations of the nine nitrosamines varied with disinfection methods and source waters. N-nitrosodimethylamine (NDMA), which is the nitrosamines of greatest concern, was identified in raw water, disinfecting water, finished water and tap water samples, ranging from 0.8 to 21.6, 0.12 to 24.2, n.d. to 8.8, and n.d. to 13.3 ng/L, respectively. Chloramination alone produced the most significant amounts of NDMA, while ozonation followed by chloramination led to moderately reduced levels. Additionally, chlorination produced relatively less NDMA, while low pressure ultraviolet radiation followed by chlorination could also significantly reduce them. Total organic carbon is one of the most important factors influencing nitrosamines formation in disinfecting water. In contrast, the addition of chlorine following any other disinfection was found to increase the formation of the other eight species of nitrosamines. The three nitrosamines recommended for monitoring by the US EPA were detected in the tap water samples, but most were present at levels below those that pose a risk to human health. Nevertheless, the occurrence and concentration of nitrosamines regulated in the Drinking Water Contaminant Candidate List could cause some potential human effects and therefore warrant attention. Copyright © 2012 Elsevier B.V. All rights reserved.
Computerized measures of finger tapping: reliability, malingering and traumatic brain injury.
Hubel, Kerry A; Yund, E William; Herron, Timothy J; Woods, David L
2013-01-01
We analyzed computerized finger tapping metrics in four experiments. Experiment 1 showed tapping-rate differences associated with hand dominance, digits, sex, and fatigue that replicated those seen in a previous, large-scale community sample. Experiment 2 revealed test-retest correlations (r = .91) that exceeded those reported in previous tapping studies. Experiment 3 investigated subjects simulating symptoms of traumatic brain injury (TBI); 62% of malingering subjects produced abnormally slow tapping rates. A tapping-rate malingering index, based on rate-independent tapping patterns, provided confirmatory evidence of malingering in 48% of the subjects with abnormal tapping rates. Experiment 4 compared tapping in 24 patients with mild TBI (mTBI) and a matched control group; mTBI patients showed slowed tapping without evidence of malingering. Computerized finger tapping measures are reliable measures of motor speed, useful in detecting subjects performing with suboptimal effort, and are sensitive to motor abnormalities following mTBI.
Jalava, Katri; Rintala, Hanna; Ollgren, Jukka; Maunula, Leena; Gomez-Alvarez, Vicente; Revez, Joana; Palander, Marja; Antikainen, Jenni; Kauppinen, Ari; Räsänen, Pia; Siponen, Sallamaari; Nyholm, Outi; Kyyhkynen, Aino; Hakkarainen, Sirpa; Merentie, Juhani; Pärnänen, Martti; Loginov, Raisa; Ryu, Hodon; Kuusi, Markku; Siitonen, Anja; Miettinen, Ilkka; Santo Domingo, Jorge W.; Hänninen, Marja-Liisa; Pitkänen, Tarja
2014-01-01
Failures in the drinking water distribution system cause gastrointestinal outbreaks with multiple pathogens. A water distribution pipe breakage caused a community-wide waterborne outbreak in Vuorela, Finland, July 2012. We investigated this outbreak with advanced epidemiological and microbiological methods. A total of 473/2931 inhabitants (16%) responded to a web-based questionnaire. Water and patient samples were subjected to analysis of multiple microbial targets, molecular typing and microbial community analysis. Spatial analysis on the water distribution network was done and we applied a spatial logistic regression model. The course of the illness was mild. Drinking untreated tap water from the defined outbreak area was significantly associated with illness (RR 5.6, 95% CI 1.9–16.4) increasing in a dose response manner. The closer a person lived to the water distribution breakage point, the higher the risk of becoming ill. Sapovirus, enterovirus, single Campylobacter jejuni and EHEC O157:H7 findings as well as virulence genes for EPEC, EAEC and EHEC pathogroups were detected by molecular or culture methods from the faecal samples of the patients. EPEC, EAEC and EHEC virulence genes and faecal indicator bacteria were also detected in water samples. Microbial community sequencing of contaminated tap water revealed abundance of Arcobacter species. The polyphasic approach improved the understanding of the source of the infections, and aided to define the extent and magnitude of this outbreak. PMID:25147923
Wang, Xianli; Kang, Haiyan; Wu, Junfeng
2016-05-01
Given the potential risks of chlorinated polycyclic aromatic hydrocarbons, the analysis of their presence in water is very urgent. We have developed a novel procedure for determining chlorinated polycyclic aromatic hydrocarbons in water based on solid-phase extraction coupled with gas chromatography and mass spectrometry. The extraction parameters of solid-phase extraction were optimized in detail. Under the optimal conditions, the proposed method showed wide linear ranges (1.0-1000 ng/L) with correlation coefficients ranging from 0.9952 to 0.9998. The limits of detection and the limits of quantification were in the range of 0.015-0.591 and 0.045-1.502 ng/L, respectively. Recoveries ranged from 82.5 to 102.6% with relative standard deviations below 9.2%. The obtained method was applied successfully to the determination of chlorinated polycyclic aromatic hydrocarbons in real water samples. Most of the chlorinated polycyclic aromatic hydrocarbons were detected and 1-monochloropyrene was predominant in the studied water samples. This is the first report of chlorinated polycyclic aromatic hydrocarbons in water samples in China. The toxic equivalency quotients of chlorinated polycyclic aromatic hydrocarbons in the studied tap water were 9.95 ng the toxic equivalency quotient m(-3) . 9,10-Dichloroanthracene and 1-monochloropyrene accounted for the majority of the total toxic equivalency quotients of chlorinated polycyclic aromatic hydrocarbons in tap water. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
González, Pablo; Sixto, Alexandra; Knochen, Moisés
2017-05-01
A novel automated method for the determination of boron based on the use of pulsed flows was developed and applied to the determination of this element in samples of tap water, ocean water and eye drops. The method was implemented by means of a multi-pumping system consisting of three solenoid micropumps and a photometric detector and exploits the reaction of azomethine-H in the presence of boron. The system runs under control of an open-source microcontroller. The main operational parameters were optimized. Given the particular kinetics of the reaction, a stopped-flow period (1 or 5min) was included to allow for color development. The method presents linearity in the range 0.35-3.0mgL -1 , good precision (s r <3%), and detection and quantification limits of 0.10 and 0.35mgL -1 respectively. Samples of tap water or eye drops could be successfully analyzed employing a 1-minute stop time, providing a maximum sampling frequency of 32 samples h -1 . In order to overcome matrix effect caused by the high saline concentration, ocean water samples required stop times of 5min, providing a sampling frequency of 10 samples h -1 . Recoveries of 102% (eye drops), 94% (drinking water) and 93% (ocean water) were obtained. The method was considered accurate and fit for the purpose. Copyright © 2015 Elsevier B.V. All rights reserved.
... for teeth, fluoride is added to many public water supplies. It's also a common ingredient in toothpaste and ... checked regularly. Drink some tap water. Most public water supplies have added fluoride, which can help reduce tooth ...
Role of water source in the growth of kale
NASA Astrophysics Data System (ADS)
Coates, M.
2017-12-01
Over the course of 2 months we watered Kale with tap water, water from turtle bayou, rain water, water from university lake, and deionized water. We found little difference between height and number of seedlings with different water treatments even though nutrient levels were different between these water sources.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crawford, Frank S.
1982-05-01
The "hot chocolate effect" was investigated quantitatively, using water. If a tall glass cylinder is filled nearly completely with water and tapped on the bottom with a softened mallet one can detect the lowest longitudinal mode of the water column, for which the height of the water column is one quarter wavelength. If the cylinder is rapidly filled with hot tap water containing dissolved air the pitch of that mode may descend by nearly three octaves during the first few seconds as the air comes out of solution and forms bubbles. Then the pitch gradually rises as the bubbles floatmore » to the top. A simple theoretical expression for the pitch ratio is derived and compared with experiment. The agreement is good to within the ten percent accuracy of the experiments.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crawford, F.S.
1982-05-01
The ''hot chocolate effect'' was investigated quantitatively, using water. If a tall glass cylinder is filled nearly completely with water and tapped on the bottom with a softened mallet one can detect the lowest longitudinal mode of the water column, for which the height of the water column is one-quarter wavelength. If the cylinder is rapidly filled with hot tap water containing dissolved air the pitch of that mode may descend by nearly three octaves during the first few seconds as the air comes out of solution and forms bubbles. Then the pitch gradually rises as the bubbles float tomore » the top. A simple theoretical expression for the pitch ratio is derived and compared with experiment. The agreement is good to within the 10% accuracy of the experiments.« less
Human exposure assessment to antibiotic-resistant Escherichia coli through drinking water.
O'Flaherty, E; Borrego, C M; Balcázar, J L; Cummins, E
2018-03-01
Antibiotic-resistant bacteria (ARB) are a potential threat to human health through drinking water with strong evidence of ARB presence in post treated tap water around the world. This study examines potential human exposure to antibiotic-resistant (AR) Escherichia coli (E. coli) through drinking water, the effect of different drinking water treatments on AR E. coli and the concentration of AR E. coli required in the source water for the EU Drinking Water Directive (DWD) (Council Directive 98/83/EC, 0CFU/100ml of E. coli in drinking water) to be exceeded. A number of scenarios were evaluated to examine different water treatment combinations and to reflect site specific conditions at a study site in Europe. A literature search was carried out to collate data on the effect of environmental conditions on AR E. coli, the effect of different water treatments on AR E. coli and typical human consumption levels of tap water. A human exposure assessment model was developed with probability distributions used to characterise uncertainty and variability in the input data. Overall results show the mean adult human exposure to AR E. coli from tap water consumption ranged between 3.44×10 -7 and 2.95×10 -1 cfu/day for the scenarios tested and varied depending on the water treatments used. The level of AR E. coli required in the source water pre-treatment to exceed the DWD varied between 1 and 5logcfu/ml, depending on the water treatments used. This can be used to set possible monitoring criteria in pre-treated water for potential ARB exposure in drinking water. Copyright © 2017 Elsevier B.V. All rights reserved.
Balogh, Zoltán; Ordögh, József; Gász, Attila; Német, László; Bender, Tamás
2005-08-01
Balneotherapy, a domain of medical science, focuses on utilizing the beneficial effects of medicinal waters. Low back pain is among the most prevalent musculoskeletal disorders affecting a large proportion of the population during their lifetime. Although small in number, all controlled studies published on this subject have demonstrated the benefits of balneotherapy. This present study was undertaken to compare the effects of hydrotherapy with mineral water vs. tap water on low back pain. A single-blind clinical study was carried out to appraise the therapeutic efficacy of reduced sulphurous water on 60 patients with low back pain. 30 subjects took baths in reduced sulphurous mineral water, whereas the other 30 patients used modified tap water of matching odor. Parameters determined at baseline, after balneo-/hydrotherapy, and at the end of the 3-month follow-up period included the results of the Visual Analogue Scale (VAS) score, the modified Oswestry index, mobility of the spine, antalgic posture, tenderness of the paravertebral muscles on palpation, the dose requirements for analgesics, and the efficacy assessed by the investigators and by the patients. Bathing in mineral water resulted in a statistically significant improvement. This was reflected by the VAS (p < 0.01) and manifested by the mitigation of muscle spasm (p < 0.01), the alleviation of local tenderness (p < 0.01), the enhanced flexion-extension and rotation of the spine (p < 0.01) as well as by the improvement of the Schober's index (p < 0.01). All these beneficial changes persisted as long as 3 months after the completion of balneotherapy. By contrast, hydrotherapy with tap water resulted only in the temporary improvement of just a single parameter: the VAS score improved significantly (p < 0.01). Balneotherapy in itself can alleviate low back pain. As demonstrated by this study, the analgesic efficacy and improvement of mobility accomplished by the use of mineral water is significantly superior to that afforded by hydrotherapy with tap water. Our results clearly establish the beneficial effects of mineral water. Moreover, it is a valuable adjunct to other forms of physical treatment as well as to pharmacotherapy.
Aprea, Luigi; Cannova, Lucia; Firenze, Alberto; Bivona, Maria S; Amodio, Emanuele; Romano, Nino
2010-12-01
Legionella pneumophila and Pseudomonas aeruginosa are common colonizers of water environments, particularly dental unit waterlines. The aim of this study was to assess whether the technical, functional and structural characteristics of dental units can influence the presence and the levels of opportunistic pathogens. Overall, 42 water samples were collected from dental units in a teaching hospital in Palermo, Italy, including 21 samples from the 21 taps supplied by the municipal water distribution system and 21 samples from oral rinsing cups at 21 dental units. L. pneumophila was present in 16 out of 21 water samples (76.2%) from dental units, and the median concentration was higher in samples from oral rinsing cups than in those from taps (P < 0.001). P. aeruginosa was equally distributed in water samples collected from oral rinsing cups and from taps. Some characteristics of dental units (age, number of chairs per room, number of patients per day and water temperature) were slightly associated with the presence of P. aeruginosa, but not with contamination by L. pneumophila. Our experience suggests that L. pneumophila is frequently detected in dental units, as reported in previous studies, whereas P. aeruginosa is not a frequent contaminant. As a consequence, microbiological control of water quality should be routinely performed, and should include the detection of opportunistic pathogens when bacterial contamination is expected.
ERIC Educational Resources Information Center
White, A. S.
1976-01-01
Describes a simple water channel, for use with an overhead projector. It is run from a water tap and may be used for flow visualization experiments, including the effect of streamlining and elementary building aerodynamics. (MLH)
Occurrence and risk assessment of organophosphate esters in drinking water from Eastern China.
Ding, Jinjian; Shen, Xiaoli; Liu, Weiping; Covaci, Adrian; Yang, Fangxing
2015-12-15
Organophosphate esters (OPEs) are ubiquitous in the environment and may pose potential health risks to humans. Drinking water is suspected as one possible exposure pathway of OPEs to humans. In this study, we investigated the residues of 9 OPEs in five types of drinking water in Eastern China. The median concentrations of Σ9OPEs were determined to be 3.99, 4.50, 27.6, 59.2 and 192ng/L in the bottled, well, barreled, direct drinking and tap waters, respectively. Triethyl phosphate (TEP) was the most abundant OPE in the tap water and filtered drinking water with median concentrations of 50.2 and 30.2ng/L, respectively. The mixture of tri(chloropropyl) phosphate (TCPP) and tri(chloroisopropyl) phosphate (TCIPP), named here as TCPP, dominated in the barreled and well water with median concentrations of 8.04 and 2.49ng/L, respectively. The calculated average daily doses of OPEs ranged from 0.14 to 7.07ng/kgbw/day for people consuming the five different types of drinking water. Among the drinking water, the tap water exhibited the highest exposure doses of OPEs. The calculated non-cancer hazard quotients (10(-4)-10(-7)) from OPEs were much lower than the theoretical threshold of risk. The carcinogenic risks posed by TCEP were very low (<10(-7)) for all types of drinking water. The results revealed that there was currently low risk to human health from exposure to OPEs through drinking water in Eastern China. Copyright © 2015 Elsevier B.V. All rights reserved.
van Lieverloo, J Hein M; Hoogenboezem, Wim; Veenendaal, Gerrit; van der Kooij, Dick
2012-10-15
A survey of invertebrates in drinking water from treatment works, internal taps and hydrants on mains was carried out by almost all water companies in the Netherlands from September 1993 to August 1995. Aquatic sow bugs (Asellidae, 1-12 mm) and oligochaeta worms (Oligochaeta, 1-100 mm), both known to have caused rare though embarrassing consumer complaints, were found to form 98% of the mean biomass in water flushed from mains. Their numbers in the mains water ranged up to 1500 (mean 37) Asellidae m(-3) and up to 9900 (mean 135) Oligochaeta m(-3). Smaller crustaceans (0.5-2 mm) dominated the numbers in water from mains. e.g. water fleas (Cladocera and Copepoda up to 14,000 m(-3)). Common invertebrates in treated water and in tap water were Rotifera (<1 mm) and nematode worms (Nematoda, <2 mm). No Asellidae, large Oligochaeta (>5 mm) or other large invertebrates were found in 1560 samples of 200 l treated water or tap water. Large variations in invertebrate abundance were found within and between distribution systems. Of the variability of mean biomass in mains per system, 55%, 60% and 63% could statistically be explained by differences in the Biofilm Formation Rate, non-particulate organic matter and the permanganate index of the treated water of the treatment works respectively. A similar correlation was found between mean invertebrate biomass and mean sediment volumes in the distribution systems (R(2) = 52%). Copyright © 2012 Elsevier Ltd. All rights reserved.
[Survey on the contamination of microcystin-LR in water supply of Shanghai city].
Wu, He-yan; Zheng, Li-xing; Su, Jin; Shi, Wei
2005-03-01
To study the pollution level of microcystin-LR in water supply of Shanghai city and the removal efficacy for microcystin-LR through routine water treatment technique. High performance liquid chromatogram (HPLC) was applied to determine the concentration of microcystin-LR in source water, water samples after various water treatment procedures and tap water. The concentration of microcystin-LR varied with sampling seasons and sites and reached peak during summer and fall. The maximum of microcystin-LR was 2.38 microg/L in source water. Coagulation plus chlorine disinfection were found to be effective for the removal of microcystin-LR, while the remove rate through filtration was not significant. And it could also be detected in tap water as high as 1.27 microg/L. The source waters of Shanghai city were polluted by cyanobacteria toxins represented by microcystin-LR. The source water in suburb was more polluted. Routine water treatment techniques can not remove the toxins effectively.
Genotoxicity and cytotoxicity assessment in lake drinking water produced in a treatment plant.
Buschini, Annamaria; Carboni, Pamela; Frigerio, Silvia; Furlini, Mariangela; Marabini, Laura; Monarca, Silvano; Poli, Paola; Radice, Sonia; Rossi, Carlo
2004-09-01
Chemical analyses and short-term mutagenicity bioassays have revealed the presence of genotoxic disinfection by-products in drinking water. In this study, the influence of the different steps of surface water treatment on drinking water mutagen content was evaluated. Four different samples were collected at a full-scale treatment plant: raw lake water (A), water after pre-disinfection with chlorine dioxide and coagulation (B), water after pre-disinfection, coagulation and granular activated carbon filtration (C) and tap water after post-disinfection with chlorine dioxide just before its distribution (D). Water samples, concentrated by solid phase adsorption on silica C18 columns, were tested in human leukocytes and HepG2 hepatoma cells using the comet assay and in HepG2 cells in the micronuclei test. A significant increase in DNA migration was observed in both cell types after 1 h treatment with filtered and tap water, and, to a lesser extent, chlorine dioxide pre-disinfected water. Similar findings were observed for the induction of "ghost" cells. Overloading of the carbon filter, with a consequent peak release, might explain the high genotoxicity found in water samples C and D. Cell toxicity and DNA damage increases were also detected in metabolically competent HepG2 cells treated with a lower concentration of tap water extract for a longer exposure time (24 h). None of the water extracts significantly increased micronuclei frequencies. Our monitoring approach appears to be able to detect contamination related to the different treatment stages before drinking water consumption and the results suggest the importance of improving the technologies for drinking water treatment to prevent human exposure to potential genotoxic compounds.
21 CFR 1250.84 - Water in galleys and medical care spaces.
Code of Federal Regulations, 2010 CFR
2010-04-01
... and in connection with garbage disposal. Any tap discharging nonpotable water which is installed for... water may continue to be so used provided controls are employed to insure the heating of all water to at...
21 CFR 1250.84 - Water in galleys and medical care spaces.
Code of Federal Regulations, 2011 CFR
2011-04-01
... and in connection with garbage disposal. Any tap discharging nonpotable water which is installed for... water may continue to be so used provided controls are employed to insure the heating of all water to at...
Harnessing Alaska. [Hydroelectric power in Alaska
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Four hydropower projects will provide electricity for isolated Alaskan cities by late 1984. A 15Mw project is already producing power. The three remaining hydro projects are described. Tyee Lake is a lake tap project. Water is supplied to the powerhouse by tapping the lake via a tunnel blasted through the lake bottom. Water then flows through a vertical pressure shaft to a power tunnel and into an aboveground powerhouse. Swan Lake consists of a double-curved arch dam and a power tunnel. Terror Lake consists of a concrete-faced compacted rockfill dam and a power tunnel.
1982-12-01
Animals were maintained ad llbltua on standard laboratory chow and tap water and were housed in a room with automatic 12 hour light and dark cycles and...supernatant fluid was centrl- fuged at 20,000 x g for 20 min to obtain a crude mitochondria ! pellet. The crude mitochondrlal pellet was resuspended...chow and tap water and wer- housed in a room with automatic 12 hour light and dark cycles and temperature set at 25.5 ± 1.8°C. DUsopropylfli’oro
Rusan, Munir J M; Albalasmeh, Ammar A; Zuraiqi, Said; Bashabsheh, Mohammad
2015-06-01
Olive-mill wastewater (OMW) is a by-product effluent of olive oil extraction process that is produced in large amount in the Mediterranean region. OMW is believed to induce phytotoxic effect on organisms including seed germination and plant growth. The objective of this study was to evaluate the impact of untreated and treated OMW with different techniques on seed germination of barley (Hordeum vulgare L.). The following treatments were investigated: (1) tap water (control); (2) OMW treated by aerobic biological technology in a Jacto Reactor (JR); (3) OMW treated by solar fenton oxidation (SFO); (4) OMW treated by microfiltration followed by nanofiltration (MF+NF); (5) OMW treated by microfiltration followed by reverse osmosis (MF+RO) process; (6) diluted OMW with tap water (25 % OMW); (7) diluted OMW with tap water (50 % OMW); (8) diluted OMW with tap water (75 % OMW); and (9) untreated OMW (100 % OMW). A germination test was conducted in an incubator at temperature of 23 (∘)C. In each petri dish, a filter paper was mounted and ten seeds of barley were placed on the filter paper. Five milliliter of water were added to each petri dish. The seed germination was determined by counting the number of germinated seeds to calculate the percentage of germination (G %). Germination rate index (GRI), seed vigor index (SVI), and phytotoxicity index (PI) were also calculated. Then, the dry weights and lengths of the shoots and the roots of the germinated seeds were measured. The results show that 100, 75, and 50 %OMW were very phytotoxic and completely prohibited seed germination. However, phytotoxicity decreased significantly following treatments of OMW with all techniques investigated and by the 25 % OMW dilution, as results of removing the phenols and other phytotoxic organic compounds from the OMW or by diluting it. This was evidenced by relative enhancement of the dry weights and lengths of shoot and root as well as the G %, GRI, SVG, and PI. It was concluded that if OMW will be used for irrigating crops, it has to be first treated or diluted with tap water at a ratio of 1:3 OMW:water at least. The most efficient treatment techniques in reducing the phytotoxicity of OMW were the MF+RO, followed by SFO and JR.
Observations and lessons learnt from more than a decade of water safety planning in South-East Asia.
Sutherland, David
2017-09-01
In many countries of the World Health Organization (WHO) South-East Asia Region, drinking water is not used directly from the tap and faecal contamination of water sources is prevalent. As reflected in Sustainable Development Goal 6, access to safer drinking water is one of the most successful ways of preventing disease. The WHO Water Safety Framework promotes the use of water safety plans (WSPs), which are structured tools that help identify and mitigate potential risks throughout a water-supply system, from the water source to the point of use. WSPs not only help prevent outbreaks of acute and chronic waterborne diseases but also improve water-supply management and performance. During the past 12 years, through the direct and indirect work of a water quality partnership supported by the Australian Government, more than 5000 urban and rural WSPs have been implemented in the region. An impact assessment based on pre- and post-WSP surveys suggests that WSPs have improved system operations and management, infrastructure and performance; leveraged donor funds; increased stakeholder communication and collaboration; increased testing of water quality; and increased monitoring of consumer satisfaction. These achievements, and their sustainability, are being achieved through national legislation and regulatory frameworks for water supply, including quality standards for drinking water; national training tools and extensive training of sector professionals and creation of WSP experts; model WSPs; WSP auditing systems; and the institution of longterm training and support. More than a decade of water safety planning using the WSP approach has shown that supplying safe drinking water at the tap throughout the WHO South-East Asia Region is a realistic goal.
Paíga, P; Santos, L H M L M; Delerue-Matos, C
2017-02-20
The aim of the present work was to develop and validate a multi-residue method for the analysis of 33 human and veterinary pharmaceuticals (non-steroidal anti-inflammatory drugs (NSAIDs)/analgesics, antibiotics and psychiatric drugs), including some of their metabolites, in several aqueous environmental matrices: drinking water, surface water and wastewaters. The method is based on solid phase extraction (SPE) followed by ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) and it was validated for different aqueous matrices, namely bottled water, tap water, seawater, river water and wastewaters, showing recoveries between 50% and 112% for the majority of the target analytes. The developed analytical methodology allowed method detection limits in the low nanograms per liter level. Method intra- and inter-day precision was under 8% and 11%, respectively, expressed as relative standard deviation. The developed method was applied to the analysis of drinking water (bottled and tap water), surface waters (seawater and river water) and wastewaters (wastewater treatment plant (WWTP) influent and effluent). Due to the selectivity and sensitivity of the optimized method, it was possible to detect pharmaceuticals in all the aqueous environmental matrices considered, including in bottled water at concentrations up to 31ngL -1 (salicylic acid). In general, non-steroidal anti-inflammatory drugs/analgesics was the therapeutic group most frequently detected, with the highest concentrations found in wastewaters (acetaminophen and the metabolite carboxyibuprofen at levels up to 615 and 120μgL -1 , respectively). Copyright © 2016 Elsevier B.V. All rights reserved.
Reduction of enteric infectious disease in rural China by providing deep-well tap water.
Wang, Z. S.; Shepard, D. S.; Zhu, Y. C.; Cash, R. A.; Zhao, R. J.; Zhu, Z. X.; Shen, F. M.
1989-01-01
Enteric infectious disease (EID), defined here as bacillary dysentery, viral hepatitis A, El Tor cholera, or acute watery diarrhoea, is an important public health problem in most developing countries. This study assessed the impact on EID of providing deep-well tap water (DWTW) through household taps in rural China. For this purpose, we compared the incidence of EID in six study villages (population, 10,290) in Qidong County that had DWTW with that in six control villages (population 9397) that had only surface water. Both the bacterial counts and chemical properties of the DWTW met established hygiene standards for drinking water. The incidence of EID in the study region was 38.6% lower than in the control region; however, the introduction of DWTW supplies did not significantly affect the incidence of bacillary dysentery. These results indicate that the construction and use of DWTW systems with household taps is associated with decreased incidences of El Tor cholera, viral hepatitis A, and acute watery diarrhoea. Since high construction costs have led many authorities to question the value of DWTW, we carried out a cost-benefit analysis of the programme. The cost of constructing a DWTW system averaged US $36,000 at 1983 prices, or US $10.50 per capita. The combined capital and operating costs of a DWTW system were US $1.46 per capita per annum over its 20-year estimated life. The benefits derived from reductions in cost of illness and savings in time to fetch water were 2.2 times the costs at present values Capital outlays were recouped in a 3.6-year payback period and the provision of DWTW proved highly beneficial in both economic and social terms. PMID:2501042
Peng, Cuilian; Liu, Cong; Tang, Xing
2010-12-01
Triamcinolone acetonide palmitate (TAP) is a lipophilic prodrug of triamcinolone acetonide (TAA) to improve the insoluble TAA physicochemical properties for the preparation of emulsions. This investigation has focused on the preformulation study of TAP, including its physicochemical properties and hydrolysis kinetics in vitro. The solubility of TAP in medium-chain triglyceride is about twice greater than that in soybean oil (long-chain triglyceride) (19.17 versus 9.55 mg/g) at 25°C, and in all investigated cases, lecithin (80, 160, and 240 mg/g) as solubilizer provided increased solubility of drugs in medium-chain triglyceride and long-chain triglyceride, whereas the maximum water solubility of TAP was 0.10 μg/mL. The partition coefficient (log P) of TAP was 5.79 irrespective of the pH conditions. The hydrolysis of TAP followed pseudo-first-order kinetics in aqueous solutions, and the stable pH range was from pH 5.0 to 9.0. The in vitro enzymolysis kinetics of TAP in rat plasma and liver homogenate was evaluated by measuring the decrease of TAP as well as the increase of TAA at 37°C for 96 hours. The results demonstrated that the TAP may be hydrolyzed mainly by rat plasma esterase and, to a minor extent, by liver esterase, and the hydrolysis half-life of TAP in 100% rat plasma was 17.53 ± 6.85 hours at pH 7.4. All these results indicated that TAP had successfully obtained higher lipid-soluble property for the preparation of intravenous emulsion and may be an effective prodrug for sustained release of TAA in vivo.
Seyfori, Hossein; Ghasemi, Hossein Ali; Hajkhodadadi, Iman; Nazaran, Mohammad Hassan; Hafizi, Maryam
2018-05-01
The effects of water supplementation of chelated trace minerals (CTM, which is named Bonzaplex designed with chelate compounds technology) on growth performance, apparent total tract digestibility (ATTD) of minerals, and some blood metabolites, TM, and antioxidant enzyme values in African ostriches were investigated from 8 to 12 months of age. A total of 20 8-month-old ostriches (five birds in five replicate pens) was randomly allocated into one of the following four treatments: (1) control (basal diet + tap water), (2) low CTM (basal diet +100 mg/bird/day CTM powder in tap water), (3) medium CTM (basal diet +1 g/bird/day CTM powder in tap water), and (4) high CTM (basal diet +2 g/bird/day CTM powder in tap water). Compared with control, medium CTM improved (P < 0.05) daily weight gain and ATTD of phosphorous, zinc, and copper in 12-month-old ostriches. Furthermore, the feed conversion ratio was lower, and ATTD of magnesium was higher in the medium- and high-CTM groups than that in the control group (P < 0.05). At the end of the trial, ostriches receiving high-CTM treatment exhibited the lower (P < 0.05) serum triglyceride and very low-density lipoprotein cholesterol concentrations and higher copper levels compared to those of the control treatment. Supplementation of higher amounts of CTM (medium and high CTM) also increased the activity of serum superoxide dismutase (P < 0.05). No differences were detected for other blood parameters including glucose, total protein, albumin, cholesterol, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol, iron, magnesium, and glutathione peroxidase values. In conclusion, supplementation of CTM at the level of 1 g/bird/day to the drinking water can be recommended for improving growth performance, mineral absorption, and antioxidant status of ostriches fed diets containing the recommended levels of inorganic TM.
Bottled Water Everywhere: Keeping it Safe
... that taps an aquifer—layers of porous rock, sand, and earth that contain water—which is under ... it to be labeled as “purified water.” Ensuring Quality and Safety Federal quality standards for bottled water ...
... bottled or purified water for drinking, washing dishes, making ice cubes, and brushing your teeth If you do use tap water, boil it or use iodine tablets Wash your hands often with soap and clean water Make sure that the cooked ...
Multiple exposures during a norovirus outbreak on a river-cruise sailing through Europe, 2006.
Verhoef, L; Boxman, I L; Duizer, E; Rutjes, S A; Vennema, H; Friesema, I H M; de Roda Husman, A M; Koopmans, M
2008-06-12
In the summer of 2006, several cruise-related viral gastroenteritis outbreaks were reported in Europe. One report came from a river-cruise, belonging to a ship-owner who had two other ships with outbreaks. This situation warranted onsite investigation in order to identify a potential common source of infection. A retrospective cohort study was performed among 137 people on board. Epidemiological questionnaire data were analysed using logistic regression. Stool, food, water and surface samples were collected for norovirus detection. Norovirus GGII.4-2006b was responsible for 48 gastroenteritis cases on this ship as confirmed in six patients. Identical norovirus sequences were detected in stool samples, on surfaces and in tap water. Epidemiological and microbiological data indicated multiple exposures contributing to the outbreak. Microbiological results demonstrated person-to-person transmission to be clearly present. Epidemiological results indicated that consuming tap water was a risk factor; however, this could not be concluded definitively on the basis of the available data. A common source for all cruise-related outbreaks was unlikely. The ongoing outbreaks on this ship demonstrated that evidence based guidelines on effective disinfection strategies are needed.
Hydrologic sections through Lee County and adjacent areas of Hendry and Collier counties, Florida
Boggess, Durward H.; Missimer, T.M.; O'Donnell, T. H.
1981-01-01
The freshwater underlying Lee, western Hendry, and northern Collier Counties occurs within the marine terrace sands, the Fort Thompson, Caloosahatchee, Tamiami, and Hawthorn Formations. These are, respectively, the water-table aquifer, an aquifer in the Tamiami Formation, and an aquifer in the upper part of the Hawthorn Formation. These aquifers are separated by clay, marl, and marly limestone. Wells tapping the water-table aquifer are commonly less than 50 feet deep, with yields ranging from 5 to 500 gallons per minute. The water quality in the aquifer is usually good, except for iron, which generally exceeds 1 milligram per liter, and color, which ranges from 30 to 600 Platinum-Cobalt units. Wells tapping the Tamiami aquifer range in depth from about 60 to 300 feet; most are less than 100 feet deep. Yields range from 20 to 500 gallons per minute. The water quality in the Tamiami aquifer is good, except where affected by leakage from deep artesian wells. Wells tapping the upper Hawthorn aquifer range in depth from about 100 to 300 feet. Yields range from 10 to 500 gallons per minute. The water quality from the upper Hawthorn aquifer is good, except in areas where upward leakage from the deep artesian aquifer has occurred. (USGS)
MEASURING & MODELING VARIATIONS IN DISTRIBUTION WATER QUALITY
Until recently most interest in drinking water quality has been in the finished water as it leaves the treatment plant. he Safe Drinking Water requires that MCLs be met at the consumers tap. ecause finished water may undergo substantial changes while being transported through the...
Quantification of Finger-Tapping Angle Based on Wearable Sensors
Djurić-Jovičić, Milica; Jovičić, Nenad S.; Roby-Brami, Agnes; Popović, Mirjana B.; Kostić, Vladimir S.; Djordjević, Antonije R.
2017-01-01
We propose a novel simple method for quantitative and qualitative finger-tapping assessment based on miniature inertial sensors (3D gyroscopes) placed on the thumb and index-finger. We propose a simplified description of the finger tapping by using a single angle, describing rotation around a dominant axis. The method was verified on twelve subjects, who performed various tapping tasks, mimicking impaired patterns. The obtained tapping angles were compared with results of a motion capture camera system, demonstrating excellent accuracy. The root-mean-square (RMS) error between the two sets of data is, on average, below 4°, and the intraclass correlation coefficient is, on average, greater than 0.972. Data obtained by the proposed method may be used together with scores from clinical tests to enable a better diagnostic. Along with hardware simplicity, this makes the proposed method a promising candidate for use in clinical practice. Furthermore, our definition of the tapping angle can be applied to all tapping assessment systems. PMID:28125051
Quantification of Finger-Tapping Angle Based on Wearable Sensors.
Djurić-Jovičić, Milica; Jovičić, Nenad S; Roby-Brami, Agnes; Popović, Mirjana B; Kostić, Vladimir S; Djordjević, Antonije R
2017-01-25
We propose a novel simple method for quantitative and qualitative finger-tapping assessment based on miniature inertial sensors (3D gyroscopes) placed on the thumb and index-finger. We propose a simplified description of the finger tapping by using a single angle, describing rotation around a dominant axis. The method was verified on twelve subjects, who performed various tapping tasks, mimicking impaired patterns. The obtained tapping angles were compared with results of a motion capture camera system, demonstrating excellent accuracy. The root-mean-square (RMS) error between the two sets of data is, on average, below 4°, and the intraclass correlation coefficient is, on average, greater than 0.972. Data obtained by the proposed method may be used together with scores from clinical tests to enable a better diagnostic. Along with hardware simplicity, this makes the proposed method a promising candidate for use in clinical practice. Furthermore, our definition of the tapping angle can be applied to all tapping assessment systems.
Sebastian, Rhonda S; Wilkinson Enns, Cecilia; Goldman, Joseph D; Moshfegh, Alanna J
2012-07-01
To provide updated estimates of drinking water intake (total, tap, plain bottled) for groups aged ≥1 year in the USA and to determine whether intakes collected in 2005-2006 using the Automated Multiple-Pass Method for the 24 h recall differ from intakes collected in 2003-2004 via post-recall food-frequency type questions. Cross-sectional, observational study. What We Eat in America (WWEIA), the dietary intake component of the US National Health and Nutrition Examination Survey (NHANES). Individuals aged ≥1 year in 2003-2004 (n 8249) and 2005-2006 (n 8437) with one complete 24 h recall. The estimate for the percentage of individuals who reported total drinking water in 2005-2006 was significantly (P < 0·0000) smaller (76·9 %) than that for 2003-2004 (87·1 %), attributable to a lower percentage reporting tap water (54·1 % in 2005-2006 v. 67·0 % in 2003-2004; P = 0·0001). Estimates of mean tap water intake differed between the survey cycles for men aged ≥71 years. Survey variables must be examined before combining or comparing data from multiple WWEIA/NHANES release cycles. For at least some age/gender groups, drinking water intake data from NHANES cycles prior to 2005-2006 should not be considered comparable to more recent data.
Wedgworth, Jessica C.; Brown, Joe; Johnson, Pauline; Olson, Julie B.; Elliott, Mark; Forehand, Rick; Stauber, Christine E.
2014-01-01
Although small, rural water supplies may present elevated microbial risks to consumers in some settings, characterizing exposures through representative point-of-consumption sampling is logistically challenging. In order to evaluate the usefulness of consumer self-reported data in predicting measured water quality and risk factors for contamination, we compared matched consumer interview data with point-of-survey, household water quality and pressure data for 910 households served by 14 small water systems in rural Alabama. Participating households completed one survey that included detailed feedback on two key areas of water service conditions: delivery conditions (intermittent service and low water pressure) and general aesthetic characteristics (taste, odor and color), providing five condition values. Microbial water samples were taken at the point-of-use (from kitchen faucets) and as-delivered from the distribution network (from outside flame-sterilized taps, if available), where pressure was also measured. Water samples were analyzed for free and total chlorine, pH, turbidity, and presence of total coliforms and Escherichia coli. Of the 910 households surveyed, 35% of participants reported experiencing low water pressure, 15% reported intermittent service, and almost 20% reported aesthetic problems (taste, odor or color). Consumer-reported low pressure was associated with lower gauge-measured pressure at taps. While total coliforms (TC) were detected in 17% of outside tap samples and 12% of samples from kitchen faucets, no reported water service conditions or aesthetic characteristics were associated with presence of TC. We conclude that consumer-reported data were of limited utility in predicting potential microbial risks associated with small water supplies in this setting, although consumer feedback on low pressure—a risk factor for contamination—may be relatively reliable and therefore useful in future monitoring efforts. PMID:25046635
Wedgworth, Jessica C; Brown, Joe; Johnson, Pauline; Olson, Julie B; Elliott, Mark; Forehand, Rick; Stauber, Christine E
2014-07-18
Although small, rural water supplies may present elevated microbial risks to consumers in some settings, characterizing exposures through representative point-of-consumption sampling is logistically challenging. In order to evaluate the usefulness of consumer self-reported data in predicting measured water quality and risk factors for contamination, we compared matched consumer interview data with point-of-survey, household water quality and pressure data for 910 households served by 14 small water systems in rural Alabama. Participating households completed one survey that included detailed feedback on two key areas of water service conditions: delivery conditions (intermittent service and low water pressure) and general aesthetic characteristics (taste, odor and color), providing five condition values. Microbial water samples were taken at the point-of-use (from kitchen faucets) and as-delivered from the distribution network (from outside flame-sterilized taps, if available), where pressure was also measured. Water samples were analyzed for free and total chlorine, pH, turbidity, and presence of total coliforms and Escherichia coli. Of the 910 households surveyed, 35% of participants reported experiencing low water pressure, 15% reported intermittent service, and almost 20% reported aesthetic problems (taste, odor or color). Consumer-reported low pressure was associated with lower gauge-measured pressure at taps. While total coliforms (TC) were detected in 17% of outside tap samples and 12% of samples from kitchen faucets, no reported water service conditions or aesthetic characteristics were associated with presence of TC. We conclude that consumer-reported data were of limited utility in predicting potential microbial risks associated with small water supplies in this setting, although consumer feedback on low pressure-a risk factor for contamination-may be relatively reliable and therefore useful in future monitoring efforts.
Liu, Chengchu; Duan, Jingyun; Su, Yi-Cheng
2006-02-15
The effects of electrolyzed oxidizing (EO) water on reducing Listeria monocytogenes contamination on seafood processing surfaces were studied. Chips (5 x 5 cm(2)) of stainless steel sheet (SS), ceramic tile (CT), and floor tile (FT) with and without crabmeat residue on the surface were inoculated with L. monocytogenes and soaked in tap or EO water for 5 min. Viable cells of L. monocytogenes were detected on all chip surfaces with or without crabmeat residue after being held at room temperature for 1 h. Soaking contaminated chips in tap water resulted in small-degree reductions of the organism (0.40-0.66 log cfu/chip on clean surfaces and 0.78-1.33 log cfu/chip on dirty surfaces). Treatments of EO water significantly (p<0.05) reduced L. monocytogenes on clean surfaces (3.73 log on SS, 4.24 log on CT, and 5.12 log on FT). Presence of crabmeat residue on chip surfaces reduced the effectiveness of EO water on inactivating Listeria cells. However, treatments of EO water also resulted in significant reductions of L. monocytogenes on dirty surfaces (2.33 log on SS and CT and 1.52 log on FT) when compared with tap water treatments. The antimicrobial activity of EO water was positively correlated with its chlorine content. High oxidation-reduction potential (ORP) of EO water also contributed significantly to its antimicrobial activity against L. monocytogenes. EO water was more effective than chlorine water on inactivating L. monocytogenes on surfaces and could be used as a chlorine alternative for sanitation purpose. Application of EO water following a thorough cleaning process could greatly reduce L. monocytogenes contamination in seafood processing environments.
Willis, Rachelle M; Stewart, Rodney A; Panuwatwanich, Kriengsak; Williams, Philip R; Hollingsworth, Anna L
2011-08-01
Within the research field of urban water demand management, understanding the link between environmental and water conservation attitudes and observed end use water consumption has been limited. Through a mixed method research design incorporating field-based smart metering technology and questionnaire surveys, this paper reveals the relationship between environmental and water conservation attitudes and a domestic water end use break down for 132 detached households located in Gold Coast city, Australia. Using confirmatory factor analysis, attitudinal factors were developed and refined; households were then categorised based on these factors through cluster analysis technique. Results indicated that residents with very positive environmental and water conservation attitudes consumed significantly less water in total and across the behaviourally influenced end uses of shower, clothes washer, irrigation and tap, than those with moderately positive attitudinal concern. The paper concluded with implications for urban water demand management planning, policy and practice. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.
Many people choose to filter or test the drinking water that comes out of their tap or from their private well for a variety of reasons. And whether at home, at work or while traveling, many Americans drink bottled water.
Data-Logging--A Plug-and-Play Oxygen Probe?
ERIC Educational Resources Information Center
Warne, Peter
1997-01-01
Presents an experiment on collecting data while measuring the dissolved-oxygen levels in Thames River tap water straight from the water mains and dissolved-oxygen levels in rainwater containing Hornwort water weed over 24 hours. (Author/ASK)
NASA Astrophysics Data System (ADS)
Landwehr, J. M.; Coplen, T. B.; Qi, H.
2009-04-01
The composition of stable isotopes of hydrogen (^2H) and oxygen (^18O) in animal tissues, such as hair, nail, teeth and bone, has been used to trace migrations and geographic origin of individuals. Variations of these isotopic ratios in tissue are known to show significant correlations with the isotopic composition of ingested water, as well as with diet and other oxygen sources. Drinking water in natural ecosystems is defined by what is locally available for animal consumption, primarily surface waters such as streams, ponds, lakes, seeps, springs, etc. Tap water provides the drinking water in many human ecosystems. It may derive from local sources but can also draw on more diverse sources, such as large rivers with watersheds larger than those of local creeks, deep ground waters or even imported supplies, which may be isotopically distinct from local ecosystem supplies. Because of the potentially complex hydrologic pathways of water sources available in either animal or human ecosystems, the stable isotopic composition of these supplies may differ significantly from that of the (weighted average) local precipitation which is sometimes used to represent local water supplies. For example, water samples taken from three different taps in Washington, D.C., USA, on August 15, 2007, had measured ^2H and ^18O values of -41.7 per mill and -6.13 per mill, -41.7 per mill and -6.06 per mill, and -42.2 per mill and -6.22 per mill, respectively. A water sample taken on the same day from the Potomac River, which is the source of the D.C. water supply, had ^2H and ^18O values of -41.7 per mill and -6.06 per mill, respectively, consistent with that of the urban tap water. However, precipitation samples collected locally in Reston, Virginia, USA, had ^2H and ^18O values of -16.1 per mill and -3.13 per mill, respectively, for the week ending on August 15, 2007; -17.5 per mill and -3.40 per mill, respectively, for the month preceding August 15, 2007; and -13.6 per mill and -3.39 per mill, respectively, for the average values for the month of August over three years. The isotopic composition of local precipitation was significantly more positive than that for the concurrently available tap water and the river water from which it was drawn. Thus, in order to allow valid geographic inferences for forensic purposes, it is necessary to have available the measured isotopic composition of drinking waters or of their appropriate sources. We have now collected tap water samples concurrently at 345 sites throughout the United States and measured ^2H and ^18O during both summer (2007) and winter (2008) seasons. Since large rivers are frequently the source of urban water supplies, we compare this information with data published for rivers and streams throughout the United States (Coplen and Kendall, 2000). These data and analyses should inform the use of stable isotopes of water for forensic determinations.
Outbreak of viral gastroenteritis due to drinking water contaminated by Norwalk-like viruses.
Kukkula, M; Maunula, L; Silvennoinen, E; von Bonsdorff, C H
1999-12-01
Heinävesi, a Finnish municipality with a population of 4860 inhabitants, had an outbreak of gastroenteritis in March 1998. On the basis of an epidemiologic survey, an estimated 1700-3000 cases of acute gastroenteritis occurred during the outbreak. Municipal water consumption was found to be associated with illness (risk ratio [RR]=3.5, 95% confidence interval, 3.11>RR>3.96). Norwalk-like virus (NLV) genogroup II (GGII) was identified in untreated water, treated water, and 4 tap water samples by use of reverse transcription-polymerase chain reaction. This was the first time NLVs had been detected in municipal tap water. Fifteen of 27 patient stool samples had NLV GGII, with an identical amplification product to that found in the water samples, indicating that the outbreak was caused by this virus. In some patients, NLV genogroup I was also encountered. This virus, however, could not be detected in the water samples. Inadequate chlorination contributed to the survival of the virus in the water.
Sasada, Tatsunari; Hinoi, Takao; Saito, Yasufumi; Adachi, Tomohiro; Takakura, Yuji; Kawaguchi, Yasuo; Sotomaru, Yusuke; Sentani, Kazuhiro; Oue, Naohide; Yasui, Wataru; Ohdan, Hideki
2015-01-01
The gastrointestinal tract is continuously exposed to a variety of chemicals and commensal bacteria. Recent studies have shown that changes in gut microbial populations caused by chlorine or other chemicals in the drinking water influence the development of human colorectal cancer, although the mechanism of tumorigenesis in the gut epithelium is obfuscated by the diversity of microflora and complexity of the tumor microenvironment. In this regard, mouse models that recapitulate human colorectal cancer are an invaluable tool. In this study, we used two conditional adenomatous polyposis coli (Apc) knockout mouse models to investigate the effect of chlorinated water on tumorigenesis in the digestive tract. Mice with colon-specific carcinoma—caused by either chromosomal (CDX2P 9.5-NLS Cre;Apc+/flox, abbreviated to CPC;Apc) or microsatellite (CDX2P9.5-G19Cre;Apcflox/flox and CDX2P9.5-G22Cre;Apcflox/flox) instability, respectively—were administered chlorinated (10.0 mg/L chlorine) or tap (0.7 mg/L chlorine) water and evaluated for colon polyp formation. In CPC;Apc mice given chlorinated drinking water, tumors tended to develop in the colon, whereas in those that drank tap water, tumors were mostly observed in the small intestine. There was no difference in the rate of tumor formation of CDX2P9.5-G19Cre;Apcflox/flox and CDX2P9.5-G22Cre;Apcflox/flox mice consuming chlorinated as compared to tap water, suggesting that microsatellite instability in the Apc gene does not significantly affect tumorigenesis. Chlorinated water altered the enteric environment by reducing the fecal populations of the obligatory anaerobes Clostridium perfringens and C. difficile, as well as species belonging to the Atopobium cluster, including Enterobacteriaceae and Staphylococcus sp., which was associated with colon tumorigenesis in CPC;Apc mice. These results suggest that differences in tumorigenesis among CPC;Apc mice consuming chlorinated versus tap water may be due to differences in gastrointestinal commensal populations. PMID:26186212
Sasada, Tatsunari; Hinoi, Takao; Saito, Yasufumi; Adachi, Tomohiro; Takakura, Yuji; Kawaguchi, Yasuo; Sotomaru, Yusuke; Sentani, Kazuhiro; Oue, Naohide; Yasui, Wataru; Ohdan, Hideki
2015-01-01
The gastrointestinal tract is continuously exposed to a variety of chemicals and commensal bacteria. Recent studies have shown that changes in gut microbial populations caused by chlorine or other chemicals in the drinking water influence the development of human colorectal cancer, although the mechanism of tumorigenesis in the gut epithelium is obfuscated by the diversity of microflora and complexity of the tumor microenvironment. In this regard, mouse models that recapitulate human colorectal cancer are an invaluable tool. In this study, we used two conditional adenomatous polyposis coli (Apc) knockout mouse models to investigate the effect of chlorinated water on tumorigenesis in the digestive tract. Mice with colon-specific carcinoma--caused by either chromosomal (CDX2P 9.5-NLS Cre;Apc(+/flox), abbreviated to CPC;Apc) or microsatellite (CDX2P9.5-G19Cre;Apc(flox/flox) and CDX2P9.5-G22Cre;Apc(flox/flox)) instability, respectively--were administered chlorinated (10.0 mg/L chlorine) or tap (0.7 mg/L chlorine) water and evaluated for colon polyp formation. In CPC;Apc mice given chlorinated drinking water, tumors tended to develop in the colon, whereas in those that drank tap water, tumors were mostly observed in the small intestine. There was no difference in the rate of tumor formation of CDX2P9.5-G19Cre;Apc(flox/flox) and CDX2P9.5-G22Cre;Apc(flox/flox) mice consuming chlorinated as compared to tap water, suggesting that microsatellite instability in the Apc gene does not significantly affect tumorigenesis. Chlorinated water altered the enteric environment by reducing the fecal populations of the obligatory anaerobes Clostridium perfringens and C. difficile, as well as species belonging to the Atopobium cluster, including Enterobacteriaceae and Staphylococcus sp., which was associated with colon tumorigenesis in CPC;Apc mice. These results suggest that differences in tumorigenesis among CPC;Apc mice consuming chlorinated versus tap water may be due to differences in gastrointestinal commensal populations.
Polarization Resistance Measurement in Tap Water: The Influence of Rust Electrochemical Activity
NASA Astrophysics Data System (ADS)
Vasyliev, Georgii
2017-08-01
Corrosion rate of mild steel in tap water during 4300 h was estimated by LPR and weight-loss methods coupled with OCP measurements. The LPR results were found to be overestimated compared to the weight-loss data within initial 2000 h of exposure. The electrochemical activity of the rust separated from the metal surface was studied by cycling voltammetry using a home-built powder graphite electrode. High redox currents corresponding to the initial 2000 h of exposure were detected. Rust composition was characterized with IR and XRD, and the highest amounts of electrochemically active β- and γ-FeOOH were again detected for the initial 2000 h. Current consumption in rust transformation processes during LPR measurement in the galvanostatic mode accounts for overestimation of the corrosion rate. The time dependence of rust electrochemical activity correlates with OCP variation with time. During initial 2000 h, OCP values are shifted by 50 mV to cathodic side. For the period of a higher rust electrochemical activity, the use of a reduced B is suggested to increase accuracy of LPR technique in tap water.
Unified Stress Tensor of the Hydration Water Layer
NASA Astrophysics Data System (ADS)
Kim, Bongsu; Kim, QHwan; Kwon, Soyoung; An, Sangmin; Lee, Kunyoung; Lee, Manhee; Jhe, Wonho
2013-12-01
We present the general stress tensor of the ubiquitous hydration water layer (HWL), based on the empirical hydration force, by combining the elasticity and hydrodynamics theories. The tapping and shear component of the tensor describe the elastic and damping properties of the HWL, respectively, in good agreement with experiments. In particular, a unified understanding of HWL dynamics provides the otherwise unavailable intrinsic parameters of the HWL, which offer additional but unexplored aspects to the supercooled liquidity of the confined HWL. Our results may allow deeper insight on systems where the HWL is critical.
Unified stress tensor of the hydration water layer.
Kim, Bongsu; Kim, Qhwan; Kwon, Soyoung; An, Sangmin; Lee, Kunyoung; Lee, Manhee; Jhe, Wonho
2013-12-13
We present the general stress tensor of the ubiquitous hydration water layer (HWL), based on the empirical hydration force, by combining the elasticity and hydrodynamics theories. The tapping and shear component of the tensor describe the elastic and damping properties of the HWL, respectively, in good agreement with experiments. In particular, a unified understanding of HWL dynamics provides the otherwise unavailable intrinsic parameters of the HWL, which offer additional but unexplored aspects to the supercooled liquidity of the confined HWL. Our results may allow deeper insight on systems where the HWL is critical.
Water quality risks of 'improved' water sources: evidence from Cambodia.
Shaheed, A; Orgill, J; Ratana, C; Montgomery, M A; Jeuland, M A; Brown, J
2014-02-01
The objective of this study was to investigate the quality of on-plot piped water and rainwater at the point of consumption in an area with rapidly expanding coverage of 'improved' water sources. Cross-sectional study of 914 peri-urban households in Kandal Province, Cambodia, between July-August 2011. We collected data from all households on water management, drinking water quality and factors potentially related to post-collection water contamination. Drinking water samples were taken directly from a subsample of household taps (n = 143), stored tap water (n = 124), other stored water (n = 92) and treated stored water (n = 79) for basic water quality analysis for Escherichia coli and other parameters. Household drinking water management was complex, with different sources used at any given time and across seasons. Rainwater was the most commonly used drinking water source. Households mixed different water sources in storage containers, including 'improved' with 'unimproved' sources. Piped water from taps deteriorated during storage (P < 0.0005), from 520 cfu/100 ml (coefficient of variation, CV: 5.7) E. coli to 1100 cfu/100 ml (CV: 3.4). Stored non-piped water (primarily rainwater) had a mean E. coli count of 1500 cfu/100 ml (CV: 4.1), not significantly different from stored piped water (P = 0.20). Microbial contamination of stored water was significantly associated with observed storage and handling practices, including dipping hands or receptacles in water (P < 0.005), and having an uncovered storage container (P = 0.052). The microbial quality of 'improved' water sources in our study area was not maintained at the point of consumption, possibly due to a combination of mixing water sources at the household level, unsafe storage and handling practices, and inadequately treated piped-to-plot water. These results have implications for refining international targets for safe drinking water access as well as the assumptions underlying global burden of disease estimates, which posit that 'improved' sources pose minimal risks of diarrhoeal diseases. © 2013 John Wiley & Sons Ltd.
Occurrence of Pseudomonas aeruginosa in waters: implications for patients with cystic fibrosis (CF).
Caskey, S; Stirling, J; Moore, J E; Rendall, J C
2018-06-01
Chronic Pseudomonas aeruginosa infection is associated with increased morbidity and mortality in patients with cystic fibrosis (CF). Current understanding of risk factors for acquisition is limited and so the aim of this study was to examine a large sample of environmental waters from diverse sources. Environmental water samples (n = 7904) from jacuzzis, hydrants, swimming pools, hot tubs, plunge pools, bottled natural mineral water, taps, springs, ice machines, water coolers, bores and showers were examined for the presence of P. aeruginosa. Pseudomonas aeruginosa was detected in 524/7904 (6·6%) waters examined. Hot tubs (51/243; 20·9%), tap water (3/40; 8%) and jacuzzis (432/5811; 7·4%) were the most likely environments where P. aeruginosa was isolated. Pseudomonas aeruginosa was isolated from bottled water (2/67; 3%). Our study highlights the ubiquitous nature of P. aeruginosa in the environment. Given CF patients are frequently counselled to make lifestyle changes to minimize P. aeruginosa exposure, these results have important implications. In particular, the occurrence of P. aeruginosa in tap water highlights the need to disinfect the CF patients' nebulizer after each use. This study examined a large number of water sources (n = 7904) over a 9-year period for the presence of Pseudomonas aeruginosa. The study highlighted that jacuzzis (n = 5811; 7% positive) and hot tubs had the highest occurrence of this organism (n = 243, 21% positive). Patients with cystic fibrosis (CF) are interested in knowing what water environments are likely to be contaminated with this organism, as this bacterium is an important cause of increased morbidity and mortality in such patients. With such information, CF patients and parents may make informed decisions about lifestyle choice and water environment avoidance. © 2018 The Society for Applied Microbiology.
Waithaka, Paul N; Maingi, John Muthini; Nyamache, Anthony Kebira
2015-01-01
Nakuru North sub-county is a peri-urban area which has both dry and wet seasons. Its residents rely mostly on untreated water sources for daily water needs due to unreliable water supply from the urban council. However, this water has not been evaluated on its quality despite residents solely depending on it. This study was aimed at determining the physico-chemical and bacteriological quality of water drawn from River Kandutura and water taps in Nakuru North sub-county. In addition, the study was aimed at carrying out sensitivity test of the isolates to antibiotics and determining effectiveness of solar disinfection in water treatment. A total of 510 water samples; river (255) and taps (255) were collected and analyzed between January and December 2013. Antimicrobial sensitivity test was carried out using Kirby Bauer disk diffusion test. Out of five hundred and ten (510) samples examined for microorganisms, 36.86 % (188/510) were positive for E. coli, Shigella and Salmonella. Water used by Nakuru North sub-county residents is highly contaminated thus posing public health risk. Solar disinfection experiment indicated a possibility of effective decontamination of water up on exposure to sun light for 3-5 h. E. coli showed the highest resistance (26.3 %) followed by Salmonella (17.4 %) while Shigella showed the least (17.1 %). However, there was no significant deference (p=0.98) in resistance among total coliforms, Total heterotrophic and Salmonella at 0.05 level of significant. There is a need to enforce laws and policies on proper waste disposal as part of water pollution control. PMID:26464611
Peng, Guilong; He, Qiang; Al-Hamadani, Sulala M Z F; Zhou, Guangming; Liu, Mengzi; Zhu, Hui; Chen, Junhua
2015-05-01
Dispersive liquid-liquid microextraction with solidification of a floating organic droplet (DLLME-SFO) followed by high performance liquid chromatography-ultraviolet (HPLC-UV) detection was applied for the determination of thiamphenicol (TAP), florfenicol (FF) in water samples. 1-Undecanol was used as the extraction solvent which has lower density than water, low toxicity, and low melting point (19°C). A mixture of 800mL acetone (disperser solvent) and 80µL of 1-undecanol (extraction solvent) was injected into 20mL of aqueous solution. After 5min, 0.6g of NaCl was added and the sample vial was shaken. After 5min, the sample was centrifuged at 3500rpm for 3min, and then placed in an ice bath. When the extraction solvent floating on the aqueous solution had solidified, it was transferred into another conical vial where it was melted quickly at room temperature, and was diluted with methanol to 1mL, and analyzed by HPLC-UV detection. Parameters influencing the extraction efficiency were thoroughly examined and optimized. The extraction recoveries (ER) and the enrichment factors (EF) ranged from 67% to 72% and 223 to 241, respectively. The limits of detection (LODs) (S/N=3) were 0.33 and 0.56µgL(-1) for TAP and FF, respectively. Linear dynamic range (LDR) was in the range of 1.0-550µgL(-1) for TAP and 1.5-700µgL(-1) for FF, the relative standard deviations (RSDs) were in the range of 2.6-3.5% and the recoveries of spiked samples ranged from 94% to 106%. Copyright © 2015 Elsevier Inc. All rights reserved.
Bouteleux, C.; Saby, S.; Tozza, D.; Cavard, J.; Lahoussine, V.; Hartemann, P.; Mathieu, L.
2005-01-01
When exposed to oxidation, algae release dissolved organic matter with significant carbohydrate (52%) and biodegradable (55 to 74%) fractions. This study examined whether algal organic matter (AOM) added in drinking water can compromise water biological stability by supporting bacterial survival. Escherichia coli (1.3 × 105 cells ml−1) was inoculated in sterile dechlorinated tap water supplemented with various qualities of organic substrate, such as the organic matter coming from chlorinated algae, ozonated algae, and acetate (model molecule) to add 0.2 ± 0.1 mg of biodegradable dissolved organic carbon (BDOC) liter−1. Despite equivalent levels of BDOC, E. coli behavior depended on the source of the added organic matter. The addition of AOM from chlorinated algae led to an E. coli growth equivalent to that in nonsupplemented tap water; the addition of AOM from ozonated algae allowed a 4- to 12-fold increase in E. coli proliferation compared to nonsupplemented tap water. Under our experimental conditions, 0.1 mg of algal BDOC was sufficient to support E. coli growth, whereas the 0.7 mg of BDOC liter−1 initially present in drinking water and an additional 0.2 mg of BDOC acetate liter−1 were not sufficient. Better maintenance of E. coli cultivability was also observed when AOM was added; cultivability was even increased after addition of AOM from ozonated algae. AOM, likely to be present in treatment plants during algal blooms, and thus potentially in the treated water may compromise water biological stability. PMID:15691924
Acute health effects after accidental exposure to styrene from drinking water in Spain
Arnedo-Pena, Alberto; Bellido-Blasco, Juan; Villamarin-Vazquez, Jose-Luis; Aranda-Mares, Jose-Luis; Font-Cardona, Nuria; Gobba, Fabriziomaria; Kogevinas, Manolis
2003-01-01
Objectives We studied subjective health symptoms in a population accidentally exposed to high styrene concentrations in drinking tap water. The contamination occurred during the reparation of a water tank. Methods Residents of 27 apartments in two buildings using the contaminated water were contacted. A questionnaire on subjective symptoms was administered to 84 out of 93 persons living in the apartments at the time of the accident. Styrene concentration was measured in samples of water collected two days after the accident. The means of exposure associated with appearance of symptoms were examined through case-control analyses. Results Styrene in water reached concentrations up to 900 μg/L. Symptoms were reported by 46 persons (attack rate 55 %). The most frequent symptoms were irritation of the throat (26%), nose (19%), eyes (18%) and the skin (14%). General gastrointestinal symptoms were observed with 11% reporting abdominal pain and 7% diarrhea. The factors most strongly associated with symptoms were drinking tap water (OR = 7.8, 95% CI 1.3–48), exposure to vapors from the basement (OR = 10.4, 2.3–47) and eating foods prepared with tap water (OR = 8.6, 1.9–40). All residents in the ground floor reported symptoms. Conclusions This accidental contamination led to very high styrene concentrations in water and was related to a high prevalence of subjective symptoms of the eyes, respiratory tract and skin. Similar exposures have been described in workers but not in subjects exposed at their residence. Various gastrointestinal symptoms were also observed in this population probably due to a local irritative effect. PMID:12777181
Zhang, Junpeng; Li, Weiying; Chen, Jiping; Qi, Wanqi; Wang, Feng; Zhou, Yanyan
2018-07-01
There is growing awareness of the antibiotic-resistance crisis and its implications for public health among clinicians, researchers, politicians, and the public. We studied bacterial antibiotic resistance transition and the role of biofilms in a drinking water distribution system (DWDS). We tracked several different antibiotic resistant bacteria (ARB) with resistance to tetracycline, sulfamethoxazole, clindamycin, and norfloxacin for one year in a DWDS. The results indicated that the amount of ARB increased in tap water, presumably due to biofilm detachment. The effect of biofilm detachment on the transmission of antibiotic resistance from biofilms to tap water was explored by using a bacterial annular reactor. The percentage of ARB of inlet water, outlet water, and biofilms ranged from 0.26% to 9.85%, 1.08%-16.29%, and 0.52%-29.97%, respectively in a chlorinated system, and from 0.23% to 9.89%, 0.84%-16.84%, and 0.35%-17.77%, respectively, in a chloraminated system. The relative abundances of antibiotic resistance Acinetobacter, Sphingomonas, and Bradyrhizobium were higher in outlet water than in inlet water, as determined by high throughout sequencing. The amount of ARB percentage varied with the concentration of viable but non-culturable (VBNC) cells (r = 0.21, n = 160, P < 0.05) in biofilm, suggesting a higher antibiotic resistance mutation rate in VBNC cells. Our results suggest that biofilm detachment was promoted by disinfectant and affected the overall bacterial antibiotic resistance of microbes in tap water. Copyright © 2018 Elsevier Ltd. All rights reserved.
Bechtel, N.; Scahill, R.I.; Rosas, H.D.; Acharya, T.; van den Bogaard, S.J.A.; Jauffret, C.; Say, M.J.; Sturrock, A.; Johnson, H.; Onorato, C.E.; Salat, D.H.; Durr, A.; Leavitt, B.R.; Roos, R.A.C.; Landwehrmeyer, G.B.; Langbehn, D.R.; Stout, J.C.; Tabrizi, S.J.; Reilmann, R.
2010-01-01
Objective: Motor signs are functionally disabling features of Huntington disease. Characteristic motor signs define disease manifestation. Their severity and onset are assessed by the Total Motor Score of the Unified Huntington's Disease Rating Scale, a categorical scale limited by interrater variability and insensitivity in premanifest subjects. More objective, reliable, and precise measures are needed which permit clinical trials in premanifest populations. We hypothesized that motor deficits can be objectively quantified by force-transducer-based tapping and correlate with disease burden and brain atrophy. Methods: A total of 123 controls, 120 premanifest, and 123 early symptomatic gene carriers performed a speeded and a metronome tapping task in the multicenter study TRACK-HD. Total Motor Score, CAG repeat length, and MRIs were obtained. The premanifest group was subdivided into A and B, based on the proximity to estimated disease onset, the manifest group into stages 1 and 2, according to their Total Functional Capacity scores. Analyses were performed centrally and blinded. Results: Tapping variability distinguished between all groups and subgroups in both tasks and correlated with 1) disease burden, 2) clinical motor phenotype, 3) gray and white matter atrophy, and 4) cortical thinning. Speeded tapping was more sensitive to the detection of early changes. Conclusion: Tapping deficits are evident throughout manifest and premanifest stages. Deficits are more pronounced in later stages and correlate with clinical scores as well as regional brain atrophy, which implies a link between structure and function. The ability to track motor phenotype progression with force-transducer-based tapping measures will be tested prospectively in the TRACK-HD study. GLOSSARY CoV = coefficient of variation; DBS = disease burden score; Freq = frequency; HD = Huntington disease; ICV = intracranial volume; IOI = interonset interval; ΔIOI = deviation from interonset interval; IPI = interpeak interval; ΔIPI = deviation from interpeak interval; ITI = intertap interval; log = logarithmic; MT = metronome tapping; ΔMTI = deviation from midtap interval; preHD = premanifest Huntington disease; RT = reaction time; ST = speeded tapping; TD = tap duration; TF = tapping force; TFC = Total Functional Capacity; UHDRS = Unified Huntington's Disease Rating Scale; UHDRS-TMS = Unified Huntington's Disease Rating Scale-Total Motor Score; VBM = voxel-based morphometry. PMID:21068430
Aparicio, Irene; Martín, Julia; Santos, Juan Luis; Malvar, José Luis; Alonso, Esteban
2017-06-02
An analytical method based on stir bar sorptive extraction (SBSE) was developed and validated for the determination of environmental concern pollutants in environmental waters by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Target compounds include six water and oil repellents (perfluorinated compounds), four preservatives (butylated hydroxytoluene and three parabens), two plasticizers (bisphenol A and di(2-ethylhexyl)phthalate), seven surfactants (four linear alkylbenzene sulfonates, nonylphenol and two nonylphenol ethoxylates), a flame retardant (hexabromocyclododecane), four hormones, fourteen pharmaceutical compounds, an UV-filter (2-ethylhexyl 4-methoxycinnamate) and nine pesticides. To achieve the simultaneous extraction of polar and non-polar pollutants two stir bar coatings were tested, the classic polydimethylsiloxane (PDMS) coating and the novel ethylene glycol modified silicone (EG-silicone). The best extraction recoveries were obtained using EG-silicone coating. The effects of sample pH, volume and ionic strength and extraction time on extraction recoveries were evaluated. The analytical method was validated for surface water and tap water samples. The method quantification limits ranged from 7.0ngL -1 to 177ngL -1 . The inter-day precision, expressed as relative standard deviation, was lower than 20%. Accuracy, expressed as relative recovery values, was in the range from 61 to 130%. The method was applied for the determination of the 48 target compounds in surface and tap water samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Diversity and Antibiotic Resistance Patterns of Sphingomonadaceae Isolates from Drinking Water▿
Vaz-Moreira, Ivone; Nunes, Olga C.; Manaia, Célia M.
2011-01-01
Sphingomonadaceae (n = 86) were isolated from a drinking water treatment plant (n = 6), tap water (n = 55), cup fillers for dental chairs (n = 21), and a water demineralization filter (n = 4). The bacterial isolates were identified based on analysis of the 16S rRNA gene sequence, and intraspecies variation was assessed on the basis of atpD gene sequence analysis. The isolates were identified as members of the genera Sphingomonas (n = 27), Sphingobium (n = 28), Novosphingobium (n = 12), Sphingopyxis (n = 7), and Blastomonas (n = 12). The patterns of susceptibility to five classes of antibiotics were analyzed and compared for the different sites of isolation and taxonomic groups. Colistin resistance was observed to be intrinsic (92%). The highest antibiotic resistance prevalence values were observed in members of the genera Sphingomonas and Sphingobium and for beta-lactams, ciprofloxacin, and cotrimoxazole. In tap water and in water from dental chairs, antibiotic resistance was more prevalent than in the other samples, mainly due to the predominance of isolates of the genera Sphingomonas and Sphingobium. These two genera presented distinct patterns of association with antibiotic resistance, suggesting different paths of resistance development. Antibiotic resistance patterns were often related to the species rather than to the site or strain, suggesting the importance of vertical resistance transmission in these bacteria. This is the first study demonstrating that members of the family Sphingomonadaceae are potential reservoirs of antibiotic resistance in drinking water. PMID:21705522
Apelfröjd, Senad; Eriksson, Sandra
2014-01-01
Results from experiments on a tap transformer based grid connection system for a variable speed vertical axis wind turbine are presented. The tap transformer based system topology consists of a passive diode rectifier, DC-link, IGBT inverter, LCL-filter, and tap transformer. Full range variable speed operation is enabled by using the different step-up ratios of a tap transformer. Simulations using MATLAB/Simulink have been performed in order to study the behavior of the system. A full experimental set up of the system has been used in the laboratory study, where a clone of the on-site generator was driven by an induction motor and the system was connected to a resistive load to better evaluate the performance. Furthermore, the system is run and evaluated for realistic wind speeds and variable speed operation. For a more complete picture of the system performance, a case study using real site Weibull parameters is done, comparing different tap selection options. The results show high system efficiency at nominal power and an increase in overall power output for full tap operation in comparison with the base case, a standard transformer. In addition, the loss distribution at different wind speeds is shown, which highlights the dominant losses at low and high wind speeds. Finally, means for further increasing the overall system efficiency are proposed.
2014-01-01
Results from experiments on a tap transformer based grid connection system for a variable speed vertical axis wind turbine are presented. The tap transformer based system topology consists of a passive diode rectifier, DC-link, IGBT inverter, LCL-filter, and tap transformer. Full range variable speed operation is enabled by using the different step-up ratios of a tap transformer. Simulations using MATLAB/Simulink have been performed in order to study the behavior of the system. A full experimental set up of the system has been used in the laboratory study, where a clone of the on-site generator was driven by an induction motor and the system was connected to a resistive load to better evaluate the performance. Furthermore, the system is run and evaluated for realistic wind speeds and variable speed operation. For a more complete picture of the system performance, a case study using real site Weibull parameters is done, comparing different tap selection options. The results show high system efficiency at nominal power and an increase in overall power output for full tap operation in comparison with the base case, a standard transformer. In addition, the loss distribution at different wind speeds is shown, which highlights the dominant losses at low and high wind speeds. Finally, means for further increasing the overall system efficiency are proposed. PMID:25258733
40 CFR 170.250 - Decontamination.
Code of Federal Regulations, 2010 CFR
2010-07-01
... illness or injury when it contacts the skin or eyes or if it is swallowed. (2) When water stored in a tank... clothing are in enclosed containers; and (iii) The water is running tap water or is enclosed in a container...
Pangloli, Philipus; Hung, Yen-Con; Beuchat, Larry R; King, C Harold; Zhao, Zhi-Hui
2009-09-01
Treatment of fresh fruits and vegetables with electrolyzed water (EW) has been shown to kill or reduce foodborne pathogens. We evaluated the efficacy of EW in killing Escherichia coli O157:H7 on iceberg lettuce, cabbage, lemons, and tomatoes by using washing and/or chilling treatments simulating those followed in some food service kitchens. Greatest reduction levels on lettuce were achieved by sequentially washing with 14-A (amperage) acidic EW (AcEW) for 15 or 30 s followed by chilling in 16-A AcEW for 15 min. This procedure reduced the pathogen by 2.8 and 3.0 log CFU per leaf, respectively, whereas washing and chilling with tap water reduced the pathogen by 1.9 and 2.4 log CFU per leaf. Washing cabbage leaves for 15 or 30 s with tap water or 14-A AcEW reduced the pathogen by 2.0 and 3.0 log CFU per leaf and 2.5 to 3.0 log CFU per leaf, respectively. The pathogen was reduced by 4.7 log CFU per lemon by washing with 14-A AcEW and 4.1 and 4.5 log CFU per lemon by washing with tap water for 15 or 30 s. A reduction of 5.3 log CFU per lemon was achieved by washing with 14-A alkaline EW for 15 s prior to washing with 14-A AcEW for 15 s. Washing tomatoes with tap water or 14-A AcEW for 15 s reduced the pathogen by 6.4 and 7.9 log CFU per tomato, respectively. Application of AcEW using procedures mimicking food service operations should help minimize cross-contamination and reduce the risk of E. coli O157:H7 being present on produce at the time of consumption.
PERSISTENCE OF WASTEWATER COMPOUNDS DURING DRINKING WATER TREATMENT: REMOVAL AND POTENTIAL EXPOSURE
The amount of water available for human consumption is becoming limited in some communities. Water reuse or recycling has become one method of overcoming this problem. Whether this takes the form of direct water reuse (toilet-to-tap), ground water recharging, or discharging eff...
Michaud, Dominique S.; Kogevinas, Manolis; Cantor, Kenneth P.; Villanueva, Cristina M.; Garcia-Closas, Monteserrat; Rothman, Nathaniel; Malats, Nuria; Real, Francisco X.; Serra, Consol; Garcia-Closas, Reina; Tardon, Adonina; Carrato, Alfredo; Dosemeci, Mustafa; Silverman, Debra T.
2007-01-01
Background Findings on water and total fluid intake and bladder cancer are inconsistent; this may, in part, be due to different levels of carcinogens in drinking water. High levels of arsenic and chlorinated by-products in drinking water have been associated with elevated bladder cancer risk in most studies. A pooled analysis based on six case–control studies observed a positive association between tap water and bladder cancer but none for nontap fluid intake, suggesting that contaminants in tap water may be responsible for the excess risk. Objectives We examined the association between total fluid and water consumption and bladder cancer risk, as well as the interaction between water intake and trihalomethane (THM) exposure, in a large case–control study in Spain. Methods A total of 397 bladder cancer cases and 664 matched controls were available for this analysis. Odds ratios (OR) were estimated using unconditional logistic regression, controlling for potential confounders. Results Total fluid intake was associated with a decrease in bladder cancer risk [OR = 0.62; 95% confidence interval (CI), 0.40–0.95 for highest vs. lowest quintile comparison]. A significant inverse association was observed for water intake (for > 1,399 vs. < 400 mL/day, OR = 0.47; 95% CI, 0.33–0.66; p for trend < 0.0001), but not for other individual beverages. The inverse association between water intake and bladder cancer persisted within each level of THM exposure; we found no statistical interaction (p for interaction = 0.13). Conclusion Findings from this study suggest that water intake is inversely associated with bladder cancer risk, regardless of THM exposure level. PMID:18007986
Acanthamoeba on Sabouraud's agar from a patient with keratitis
Baradkar, Vasant; Samal, Badhuli; Mali, Swapna A; Kulkarni, Ketaki; Shastri, Jayanthi
2011-01-01
A 25-year-old transgender patient came with complaints of watery discharge, red eye and photophobia in the left eye since 2 days. The patient had a history of wearing colored contact lenses since 4 years and cleaning the lens with tap water. Culture of lenses on Mac Conkey and blood agar yielded Klebsiella pneumoniae and Pseudomonas aeruginosa. Sabouroud's agar showed yeast cells and double-walled cysts of Acanthamoeba species. On further incubation of Sabouroud's agar, the cysts transformed to trophozoites. Parallel results were obtained on tap water agar. The previous therapy of moxifloxacin was changed to local Neosporin application. PMID:23508061
A Drinking Water Sensor for Lead and Other Heavy Metals.
Lin, Wen-Chi; Li, Zhongrui; Burns, Mark A
2017-09-05
Leakage of lead and other heavy metals into drinking water is a significant health risk and one that is not easily detected. We have developed simple sensors containing only platinum electrodes for the detection of heavy metal contamination in drinking water. The two-electrode sensor can identify the existence of a variety of heavy metals in drinking water, and the four-electrode sensor can distinguish lead from other heavy metals in solution. No false-positive response is generated when the sensors are placed in simulated and actual tap water contaminated by heavy metals. Lead detection on the four-electrode sensor is not affected by the presence of common ions in tap water. Experimental results suggest the sensors can be embedded in water service lines for long-time use until lead or other heavy metals are detected. With its low cost (∼$0.10/sensor) and the possibility of long-term operation, the sensors are ideal for heavy metal detection of drinking water.
Risk assessment of fluoride exposure in drinking water of Tunisia.
Guissouma, Wiem; Hakami, Othman; Al-Rajab, Abdul Jabbar; Tarhouni, Jamila
2017-06-01
The presence of fluoride in drinking water is known to reduce dental cavities among consumers, but an excessive intake of this anion might leads to dental and skeletal fluorosis. This study reports a complete survey of the fluoridated tap water taken from 100 water consumption points in Tunisia. The fluoride concentrations in tap water were between 0 and 2.4 mg L -1 . Risk assessment of Fluoride exposure was assessed depending on the age of consumers using a four-step method: hazard identification, toxicity reference values selection (TRVs), daily exposure assessment, and risk characterization. Our findings suggest that approximately 75% of the Tunisian population is at risk for dental decay, 25% have a potential dental fluorosis risk, and 20% might have a skeletal fluorosis risk according to the limits of fluoride in drinking water recommended by WHO. More investigations are recommended to assess the exposure risk of fluoride in other sources of drinking water such as bottled water. Copyright © 2017 Elsevier Ltd. All rights reserved.
Point-of-entry drinking-water treatment systems for Superfund applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chambers, C.D.; Janszen, T.A.
1989-06-01
The U.S. Environmental Protection Agency (EPA) and State Superfund agencies need a technical manual to assist their personnel in the selection of an effective drinking-water treatment system for individual households in areas where the drinking water has been adversely affected by Superfund site contaminants and no other alternative water supply is available or feasible. Commercially available water treatment systems for individual households are of two basic types: point-of-use (POU) and point-of-entry (POE). A POU device consists of equipment applied to selected water taps to reduce contaminants at each tap. A POE device consists of equipment to reduce the contaminants inmore » the water distributed throughout the entire structure of a house. The study was initiated to collect monitoring, operation and maintenance, performance, and design data on existing Superfund POE water-treatment systems. Evaluation of the collected data showed that the existing data are not sufficient for the preparation of a technical assistance document to meet the objectives of EPA and State Superfund personnel.« less
Assessment of age-dependent uranium intake due to drinking water in Hyderabad, India.
Balbudhe, A Y; Srivastava, S K; Vishwaprasad, K; Srivastava, G K; Tripathi, R M; Puranik, V D
2012-03-01
A study has been done to assess the uranium intake through drinking water. The area of study is twin cities of Hyderabad and Secunderabad, India. Uranium concentration in water samples was analysed by laser-induced fluorimetry. The associated age-dependent uranium intake was estimated by taking the prescribed water intake values. The concentration of uranium varies from below detectable level (minimum detectable level = 0.20 ± 0.02 μg l(-1)) to 2.50 ± 0.18 μg l(-1), with the geometric mean (GM) of 0.67 μg l(-1) in tap water, whereas in ground water, the range is 0.60 ± 0.05 to 82 ± 7.1 µg l(-1) with GM of 10.07 µg l(-1). The daily intake of uranium by drinking water pathway through tap water for various age groups is found to vary from 0.14 to 9.50 µg d(-1) with mean of 1.55 µg d(-1).
Investigation of Waikele well no 2401-01, Oahu, Hawaii; pumping test, well logs and water quality
Eyre, P.R.
1983-01-01
Field tests indicate that an abandoned well (No. 2401-01) near the confluence of Waikele and Kipapa Streams, Oahu, Hawaii, can be reactivated to produce potable water at a rate of 400-500 gallons per minute. Previous tests in 1946 and 1954 indicated that the well tapped the brackish transition zone which inderlies the Ghyben-Herzberg lens of the Pearl Harbor aquifer. Results of this study, based on geologic and geophysical logs of the wall, as well as on pumping test and water-quality data, indicate that the slightly brackish water produced by the well results from brackish irrigation return water. It does not appear that pumping from this well will cause seawater upconing or intrusion. (USGS)
Oxygen absorption by skin exposed to oxygen supersaturated water.
Reading, Stacey A; Yeomans, Maggie
2012-05-01
The present study tests the hypothesis that skin on the plantar surface of the foot absorbs oxygen (O(2)) when immersed in water that has a high dissolved O(2) content. Healthy male and female subjects (24.2 ± 1.4 years) soaked each foot in tap water (1.7 ± 0.1 mg O(2)·L(-1); 30.7 ± 0.3 °C) or O(2)-infused water (50.2 ± 1.7 mg O(2)·L(-1); 32.1 ± 0.5 °C) for up to 30 min in 50 different experiments. Transcutaneous oximetry and near infrared spectroscopy were used to evaluate changes in skin PO(2), oxygenated haemoglobin, and cytochrome oxidase aa(3) that resulted from treatment. Compared with the tap water condition, tissue oxygenation index was 3.5% ± 1.3% higher in feet treated for 30 min with O(2)-infused water. This effect persisted after treatment, as skin PO(2) was higher in feet treated with O(2)-infused water at 2 min (237 ± 9 vs. 112 ± 5 mm HG) and 15 min (131 ± 1 vs. 87 ± 4 mm HG) post-treatment. When blood flow to the foot was occluded for 5 min, feet resting in O(2)-infused water maintained a 3-fold higher O(2) consumption rate than feet treated with tap water (9.1 ± 1.4 vs. 3.0 ± 1.0 µL·100 g(-1)·min(-1)). We estimate that skin absorbs 4.5 mL of O(2)·m(-2)·min(-1) from O(2)-infused water. Thus, skin absorbs appreciable amounts of O(2) from O(2)-infused water. This finding may prove useful and assist development of treatments targeting skin diseases with ischemic origin.
Blue Laser Diode Enables Underwater Communication at 12.4 Gbps
Wu, Tsai-Chen; Chi, Yu-Chieh; Wang, Huai-Yung; Tsai, Cheng-Ting; Lin, Gong-Ru
2017-01-01
To enable high-speed underwater wireless optical communication (UWOC) in tap-water and seawater environments over long distances, a 450-nm blue GaN laser diode (LD) directly modulated by pre-leveled 16-quadrature amplitude modulation (QAM) orthogonal frequency division multiplexing (OFDM) data was employed to implement its maximal transmission capacity of up to 10 Gbps. The proposed UWOC in tap water provided a maximal allowable communication bit rate increase from 5.2 to 12.4 Gbps with the corresponding underwater transmission distance significantly reduced from 10.2 to 1.7 m, exhibiting a bit rate/distance decaying slope of −0.847 Gbps/m. When conducting the same type of UWOC in seawater, light scattering induced by impurities attenuated the blue laser power, thereby degrading the transmission with a slightly higher decay ratio of 0.941 Gbps/m. The blue LD based UWOC enables a 16-QAM OFDM bit rate of up to 7.2 Gbps for transmission in seawater more than 6.8 m. PMID:28094309
NASA Astrophysics Data System (ADS)
Xu, Wanzhen; Zhang, Xiaoming; Huang, Weihong; Luan, Yu; Yang, Yanfei; Zhu, Maiyong; Yang, Wenming
2017-12-01
In this work, the molecular imprinted polymers were synthesized with the low monomer concentrations for dibutyl phthalate (DBP). The polymers were prepared over carboxyl-modified silica nanoparticle, which used methacrylic acid as the functional monomer, ethylene glycol dimethacrylate as the cross-linker agent and azoisobutyronitrile as the initiator in the process of preparation. Various measures were used to characterize the structure and morphology in order to get the optimal polymer. The characterization results show that the optimal polymer has suitable features for further adsorption process. And adsorption capacity experiments were evaluated to analyze its adsorption performance, through adsorption isotherms/kinetics, selectivity adsorption and desorption and regeneration experiments. These results showed that the molecular imprinted polymers had a short equilibrium time about 60 min and high stability with 88% after six cycles. Furthermore, the molecular imprinted polymers were successfully applied to remove dibutyl phthalate. The concentration range was 5.0-30.0 μmol L-1, and the limit of detection was 0.06 μmol L-1 in tap water samples.
NASA Technical Reports Server (NTRS)
Gooding, James L.; Ming, Douglas W.; Allton, Judith H.; Byers, Terry B.; Dunn, Robert P.; Gibbons, Frank L.; Pate, Daniel B.; Polette, Thomas M.
1992-01-01
Physical and chemical interactions between the surface and atmosphere of Mars can be expected to embody a strong cause-and-effect relationship with the minerals comprising the martian regolith. Many of the minerals in soils and sediments are probably products of chemical weathering (involving surface/atmosphere or surface/hydrosphere reactions) that could be expected to subsequently influence the sorption of atmospheric gases and water vapor. Therefore, identification of the minerals in martian surface soils and sediments is essential for understanding both past and present interactions between the Mars surface and atmosphere. Clearly, the most definitive mineral analyses would be achieved with well-preserved samples returned to Earth-based laboratories. In advance of a Mars sample return mission, however, significant progress could be made with in situ experiments that fill current voids in knowledge about the presence or abundance of key soil minerals such as clays (layered-structured silicates), zeolites, and various salts, including carbonates. TAPS is intended to answer that challenge by providing first-order identification of soil and sediment minerals.
Performance of a novel high throughput method for the determination of VX in drinking water samples.
Knaack, Jennifer S; Zhou, Yingtao; Magnuson, Matthew; Silvestri, Erin; Johnson, Rudolph C
2013-03-05
VX (O-ethyl-S-(2-diisopropylaminoethyl) methylphosphonothioate) is a highly toxic organophosphorus nerve agent, and even low levels of contamination in water can be harmful. Measurement of low concentrations of VX in aqueous matrixes is possible using an immunomagnetic scavenging technique and detection using liquid chromatography/tandem-mass spectrometry. Performance of the method was characterized in high-performance liquid chromatography (HPLC)-grade water preserved with sodium omadine, an antimicrobial agent, and sodium thiosulfate, a dechlorinating agent, over eight analytical batches with quality control samples analyzed over 10 days. The minimum reportable level was 25 ng/L with a linear dynamic range up to 4.0 μg/L. The mean accuracies for two quality control samples containing VX at concentrations of 0.250 and 2.00 μg/L were 102 ± 3% and 103 ± 6%, respectively. The stability of VX was determined in five tap water samples representing a range of water quality parameters and disinfection practices over a 91 day period. In preserved tap water samples, VX recovery was between 81 and 92% of the fortified amount, 2.0 μg/L, when analyzed immediately after preparation. Recovery of VX decreased to between 31 and 45% of the fortified amount after 91 days, indicating hydrolysis of VX. However, the preservatives minimized the hydrolysis rate to close to the theoretical limit. The ability to detect low concentrations of VX in preserved tap water 91 days after spiking suggests applicability of this method for determining water contamination with VX and utility during environmental remediation.