Sample records for tape measure distance

  1. Effect of tape recording on perturbation measures.

    PubMed

    Jiang, J; Lin, E; Hanson, D G

    1998-10-01

    Tape recorders have been shown to affect measures of voice perturbation. Few studies, however, have been conducted to quantitatively justify the use or exclusion of certain types of recorders in voice perturbation studies. This study used sinusoidal and triangular waves and synthesized vowels to compare perturbation measures extracted from directly digitized signals with those recorded and played back through various tape recorders, including 3 models of digital audio tape recorders, 2 models of analog audio cassette tape recorders, and 2 models of video tape recorders. Signal contamination for frequency perturbation values was found to be consistently minimal with digital recorders (percent jitter = 0.01%-0.02%), mildly increased with video recorders (0.05%-0.10%), moderately increased with a high-quality analog audio cassette tape recorder (0.15%), and most prominent with a low-quality analog audio cassette tape recorder (0.24%). Recorder effect on amplitude perturbation measures was lowest in digital recorders (percent shimmer = 0.09%-0.20%), mildly to moderately increased in video recorders and a high-quality analog audio cassette tape recorder (0.25%-0.45%), and most prominent in a low-quality analog audio cassette tape recorder (0.98%). The effect of cassette tape material, length of spooled tape, and duration of analysis were also tested and are discussed.

  2. Accuracy testing of steel and electric groundwater-level measuring tapes: Test method and in-service tape accuracy

    USGS Publications Warehouse

    Fulford, Janice M.; Clayton, Christopher S.

    2015-10-09

    The calibration device and proposed method were used to calibrate a sample of in-service USGS steel and electric groundwater tapes. The sample of in-service groundwater steel tapes were in relatively good condition. All steel tapes, except one, were accurate to ±0.01 ft per 100 ft over their entire length. One steel tape, which had obvious damage in the first hundred feet, was marginally outside the accuracy of ±0.01 ft per 100 ft by 0.001 ft. The sample of in-service groundwater-level electric tapes were in a range of conditions—from like new, with cosmetic damage, to nonfunctional. The in-service electric tapes did not meet the USGS accuracy recommendation of ±0.01 ft. In-service electric tapes, except for the nonfunctional tape, were accurate to about ±0.03 ft per 100 ft. A comparison of new with in-service electric tapes found that steel-core electric tapes maintained their length and accuracy better than electric tapes without a steel core. The in-service steel tapes could be used as is and achieve USGS accuracy recommendations for groundwater-level measurements. The in-service electric tapes require tape corrections to achieve USGS accuracy recommendations for groundwater-level measurement.

  3. Tape functionality: sonographic tape characteristics and outcome after TVT incontinence surgery.

    PubMed

    Kociszewski, Jacek; Rautenberg, Oliver; Perucchini, Daniele; Eberhard, Jakob; Geissbühler, Verena; Hilgers, Reinhard; Viereck, Volker

    2008-01-01

    To investigate tension-free vaginal tape (TVT) position and shape using ultrasound (US) and correlate the findings to outcome. The results of TVT surgery were investigated in 72 women with urodynamic stress urinary incontinence. The main outcome parameters were US tape position in relation to the urethra and dynamic changes in TVT shape at rest and during straining. Sixty-two patients (86%) were continent, 6 (8%) significantly improved, and the operation failed in four cases (6%). The median tape position was at 66% of the urethral length measured by US. The median tape-urethra-lumen distance was 3.8 mm at rest. Tape placement in the upper or lower quarter of the urethra was associated with a higher failure rate. Tapes positioned less than 3 mm from the urethra significantly increased postoperative complications (P < 0.0001). The tape was flat at rest and curved during straining in 44 (61%) patients; 98% (43/44) of these women were continent after surgery. An unchanged tape shape was associated with a poorer outcome (P = 0.00038). Patients with a flat tape at rest and during straining failed in 25% and patients with a permanent curved shape in 10%. TVT position relative to the patient's urethra seems to play a role in treatment outcome. Outcome was best in patients with dynamic change in tape shape during straining and location of the tape at the junction between the lower and middle urethra and at least 3 mm from the urethral lumen. (c) 2008 Wiley-Liss, Inc.

  4. Acute effects of scapular Kinesio Taping® on shoulder rotator strength, ROM and acromiohumeral distance in asymptomatic overhead athletes.

    PubMed

    Harput, Gulcan; Guney, Hande; Toprak, Ugur; Colakoglu, Filiz; Baltaci, Gul

    2017-11-01

    There is limited information in the literature that shows whether scapular taping has an effect on the acromiohumeral distance (AHD) and shoulder functions. The aim of this study was to investigate the acute effects of scapular Kinesio Taping® on shoulder internal rotation (IR) and external rotation (ER) strength, IR and ER range of motion (ROM) and AHD in asymptomatic overhead athletes. Forty-one volleyball athletes (24 men, 17 women; mean age: 16.1±1.5 years, body mass: 66.5±9.6 kg, body height: 179.6±8.4 cm, Body Mass Index: 20.5±2.3 kg/m2, time participating in overhead sports activity: 6.2±1.4 h/week, experience in sport: 4.1±2.4 years) were included in this study. Shoulder IR and ER ROM, total rotation ROM, AHD, shoulder isometric IR and ER strength and ER:IR strength ratio of the dominant side were tested before and after taping. Scapular taping increased the shoulder IR (P<0.001) and total ROM (P<0.001), AHD (P<0.001), shoulder IR (P=0.002) and ER (P=0.006) strength. ER ROM and ER:IR ratio did not change after taping (P=0.26, P=0.98, respectively). The results of this study suggest that scapular taping could be an effective method for enhancing the acromiohumeral distance, shoulder rotator strength and range of motion. Therefore, scapular taping could be recommended for not only in the asymptomatic athletes' shoulder exercise training but also in the prevention of subacromial impingement syndrome.

  5. Patellar taping, patellofemoral pain syndrome, lower extremity kinematics, and dynamic postural control.

    PubMed

    Aminaka, Naoko; Gribble, Phillip A

    2008-01-01

    Patellar taping has been a part of intervention for treatment of patellofemoral pain syndrome (PFPS). However, research on the efficacy of patellar taping on lower extremity kinematics and dynamic postural control is limited. To evaluate the effects of patellar taping on sagittal-plane hip and knee kinematics, reach distance, and perceived pain level during the Star Excursion Balance Test (SEBT) in individuals with and without PFPS. Repeated-measures design with 2 within-subjects factors and 1 between-subjects factor. The University of Toledo Athletic Training Research Laboratory. Twenty participants with PFPS and 20 healthy participants between the ages of 18 and 29 years. The participants performed 3 reaches of the SEBT in the anterior direction under tape and no-tape conditions on both legs. The participants' hip and knee sagittal-plane kinematics were measured using the electromagnetic tracking system. Reach distance was recorded by hand and was normalized by dividing the distance by the participants' leg length (%MAXD). After each taping condition on each leg, the participants rated the perceived pain level using the 10-cm visual analog scale. The participants with PFPS had a reduction in pain level with patellar tape application compared with the no-tape condition (P = .005). Additionally, participants with PFPS demonstrated increased %MAXD under the tape condition compared with the no-tape condition, whereas the healthy participants demonstrated decreased %MAXD with tape versus no tape (P = .028). No statistically significant differences were noted in hip flexion and knee flexion angles. Although patellar taping seemed to reduce pain and improve SEBT performance of participants with PFPS, the exact mechanisms of these phenomena cannot be explained in this study. Further research is warranted to investigate the effect of patellar taping on neuromuscular control during dynamic postural control.

  6. A prospective randomized blister prevention trial assessing paper tape in endurance distances (Pre-TAPED).

    PubMed

    Lipman, Grant S; Ellis, Mark A; Lewis, Erica J; Waite, Brandee L; Lissoway, John; Chan, Garrett K; Krabak, Brian J

    2014-12-01

    Friction foot blisters are a common injury occurring in up to 39% of marathoners, the most common injury in adventure racing, and represent more than 70% of medical visits in multi-stage ultramarathons. The goal of the study was to determine whether paper tape could prevent foot blisters in ultramarathon runners. This prospective randomized trial was undertaken during RacingThePlanet 155-mile (250-km), 7-day self-supported ultramarathons in China, Australia, Egypt, Chile, and Nepal in 2010 and 2011. Paper tape was applied prerace to one randomly selected foot, with the untreated foot acting as the own control. The study end point was development of a hot spot or blister on any location of either foot. One hundred thirty-six participants were enrolled with 90 (66%) having completed data for analysis. There were 36% women, with a mean age of 40 ± 9.4 years (range, 25-40 years) and pack weight of 11 ± 1.8 kg (range, 8-16 kg). All participants developed blisters, with 89% occurring by day 2 and 59% located on the toes. No protective effect was observed by the intervention (47 versus 35; 52% versus 39%; P = .22), with fewer blisters occurring around the tape on the experimental foot than under the tape (23 vs 31; 25.6% versus 34.4%), yet 84% of study participants when queried would choose paper tape for blister prevention in the future. Although paper tape was not found to be significantly protective against blisters, the intervention was well tolerated with high user satisfaction. Copyright © 2014 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  7. Software Computes Tape-Casting Parameters

    NASA Technical Reports Server (NTRS)

    deGroh, Henry C., III

    2003-01-01

    Tcast2 is a FORTRAN computer program that accelerates the setup of a process in which a slurry containing metal particles and a polymeric binder is cast, to a thickness regulated by a doctor blade, onto fibers wound on a rotating drum to make a green precursor of a metal-matrix/fiber composite tape. Before Tcast2, setup parameters were determined by trial and error in time-consuming multiple iterations of the process. In Tcast2, the fiber architecture in the final composite is expressed in terms of the lateral distance between fibers and the thickness-wise distance between fibers in adjacent plies. The lateral distance is controlled via the manner of winding. The interply spacing is controlled via the characteristics of the slurry and the doctor-blade height. When a new combination of fibers and slurry is first cast and dried to a green tape, the shrinkage from the wet to the green condition and a few other key parameters of the green tape are measured. These parameters are provided as input to Tcast2, which uses them to compute the doctor-blade height and fiber spacings needed to obtain the desired fiber architecture and fiber volume fraction in the final composite.

  8. Accuracy testing of electric groundwater-level measurement tapes

    USGS Publications Warehouse

    Jelinski, Jim; Clayton, Christopher S.; Fulford, Janice M.

    2015-01-01

    The accuracy tests demonstrated that none of the electric-tape models tested consistently met the suggested USGS accuracy of ±0.01 ft. The test data show that the tape models in the study should give a water-level measurement that is accurate to roughly ±0.05 ft per 100 ft without additional calibration. To meet USGS accuracy guidelines, the electric-tape models tested will need to be individually calibrated. Specific conductance also plays a part in tape accuracy. The probes will not work in water with specific conductance values near zero, and the accuracy of one probe was unreliable in very high conductivity water (10,000 microsiemens per centimeter).

  9. Tape Placement Head for Applying Thermoplastic Tape to an Object

    NASA Technical Reports Server (NTRS)

    Cope, Ralph D. (Inventor); Funck, Steve B. (Inventor); Gruber, Mark B. (Inventor); Lamontia, Mark A. (Inventor); Johnson, Anthony D. (Inventor)

    2008-01-01

    A tape placement head for applying thermoplastic tape to an object includes a heated feeder which guides the tape/tow to a heated zone. The heated zone has a line compactor having a single row of at least one movable heated member. An area compactor is located in the heated zone downstream from the line compactor. The area compactor includes a plurality of rows of movable feet which are extendable toward the tape/tow different distances with respect to each other to conform to the shape of the object. A shim is located between the heated compactors and the tape/tow. A chilled compactor is in a chilled zone downstream from the heated zone. The chilled zone includes a line chilled compactor and an area chilled compactor. A chilled shim is mounted between the chilled compactor and the tape/tow.

  10. Tape-Drop Transient Model for In-Situ Automated Tape Placement of Thermoplastic Composites

    NASA Technical Reports Server (NTRS)

    Costen, Robert C.; Marchello, Joseph M.

    1998-01-01

    Composite parts of nonuniform thickness can be fabricated by in-situ automated tape placement (ATP) if the tape can be started and stopped at interior points of the part instead of always at its edges. This technique is termed start/stop-on-the-part, or, alternatively, tape-add/tape-drop. The resulting thermal transients need to be managed in order to achieve net shape and maintain uniform interlaminar weld strength and crystallinity. Starting-on-the-part has been treated previously. This paper continues the study with a thermal analysis of stopping-on-the-part. The thermal source is switched off when the trailing end of the tape enters the nip region of the laydown/consolidation head. The thermal transient is determined by a Fourier-Laplace transform solution of the two-dimensional, time-dependent thermal transport equation. This solution requires that the Peclet number Pe (the dimensionless ratio of inertial to diffusive heat transport) be independent of time and much greater than 1. Plotted isotherms show that the trailing tape-end cools more rapidly than the downstream portions of tape. This cooling can weaken the bond near the tape end; however the length of the affected region is found to be less than 2 mm. To achieve net shape, the consolidation head must continue to move after cut-off until the temperature on the weld interface decreases to the glass transition temperature. The time and elapsed distance for this condition to occur are computed for the Langley ATP robot applying PEEK/carbon fiber composite tape and for two upgrades in robot performance. The elapsed distance after cut-off ranges from about 1 mm for the present robot to about 1 cm for the second upgrade.

  11. A new method of measurement of tension on a moving magnetic tape

    NASA Technical Reports Server (NTRS)

    Kurtinaytis, A. K.; Lauzhinskas, Y. S.

    1973-01-01

    The possibility of no-contact measurement of the tension on a moving magnetic tape, assuming the tape is uniform, is discussed. A scheme for calculation of the natural frequency of transverse vibrations of magnetic tape is shown. Mathematical models are developed to show the relationships of the parameters. The method is applicable to the analysis of accurate tape feed mechanisms design.

  12. Paper Tape Prevents Foot Blisters: A Randomized Prevention Trial Assessing Paper Tape in Endurance Distances II (Pre-TAPED II).

    PubMed

    Lipman, Grant S; Sharp, Louis J; Christensen, Mark; Phillips, Caleb; DiTullio, Alexandra; Dalton, Andrew; Ng, Pearlly; Shangkuan, Jennifer; Shea, Katherine; Krabak, Brian J

    2016-09-01

    To determine whether paper tape prevents foot blisters in multistage ultramarathon runners. Multisite prospective randomized trial. The 2014 250-km (155-mile) 6-stage RacingThePlanet ultramarathons in Jordan, Gobi, Madagascar, and Atacama Deserts. One hundred twenty-eight participants were enrolled: 19 (15%) from the Jordan, 35 (27%) from Gobi, 21 (16%) from Madagascar, and 53 (41%) from the Atacama Desert. The mean age was 39.3 years (22-63) and body mass index was 24.2 kg/m (17.4-35.1), with 31 (22.5%) females. Paper tape was applied to a randomly selected foot before the race, either to participants' blister-prone areas or randomly selected location if there was no blister history, with untaped areas of the same foot used as the control. Development of a blister anywhere on the study foot. One hundred six (83%) participants developed 117 blisters, with treatment success in 98 (77%) runners. Paper tape reduced blisters by 40% (P < 0.01, 95% confidence interval, 28-52) with a number needed to treat of 1.31. Most of the study participants had 1 blister (78%), with most common locations on the toes (n = 58, 50%) and heel (n = 27, 23%), with 94 (80%) blisters occurring by the end of stage 2. Treatment success was associated with earlier stages [odds ratio (OR), 74.9, P < 0.01] and time spent running (OR, 0.66, P = 0.01). Paper tape was found to prevent both the incidence and frequency of foot blisters in runners.

  13. Distanced Data: Transcribing Other People's Research Tapes

    ERIC Educational Resources Information Center

    Tilley, Susan A.; Powick, Kelly D.

    2004-01-01

    In this article, we report on our qualitative study involving eight individuals hired to transcribe research tapes in university contexts. We consider issues of data analysis and data trustworthiness and the implications for both when transcription is assigned to someone other than the researcher. We explore the challenges transcribers faced…

  14. The Use of Video-Taped Lectures and Web-Based Communications in Teaching: A Distance-Teaching and Cross-Atlantic Collaboration Experiment.

    ERIC Educational Resources Information Center

    Herder, P. M.; Subrahmanian, E.; Talukdar, S.; Turk, A. L.; Westerberg, A. W.

    2002-01-01

    Explains distance education approach applied to the 'Engineering Design Problem Formulation' course simultaneously at the Delft University of Technology (the Netherlands) and at Carnegie Mellon University (CMU, Pittsburgh, USA). Uses video taped lessons, video conferencing, electronic mails and web-accessible document management system LIRE in the…

  15. Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grin, A.; Lstiburek, J.

    The goal of this research is to provide durable and long-term water management solutions using exterior insulating sheathing as part of the water management system. It is possible to tape or seal the joints in insulating sheathing to create a drainage plane and even an air control layer. There exists the material durability component of the tape as well as the system durability component being the taped insulating sheathing as the drainage plane. This measure guideline provides best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant issues weremore » discussed with the group, which are required to make taped insulating sheathing a simple, long-term, and durable drainage plane: horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists use superior materials; and frequent installation inspection and regular trade training are required to maintain proper installation.« less

  16. INVESTIGATING THE EFFECTIVENESS OF KINESIO® TAPING SPACE CORRECTION METHOD IN HEALTHY ADULTS ON PATELLOFEMORAL JOINT AND SUBCUTANEOUS SPACE.

    PubMed

    Lyman, Katie J; Keister, Kassiann; Gange, Kara; Mellinger, Christopher D; Hanson, Thomas A

    2017-04-01

    Limited quantitative, physiological evidence exists regarding the effectiveness of Kinesio® Taping methods, particularly with respect to the potential ability to impact underlying physiological joint space and structures. To better understand the impact of these techniques, the underlying physiological processes must be investigated in addition to the examination of more subjective measures related to pain in unhealthy tissues. The purpose of this study was to determine whether the Kinesio® Taping Space Correction Method created a significant difference in patellofemoral joint space, as quantified by diagnostic ultrasound. Pre-test/post-test prospective cohort study. Thirty-two participants with bilaterally healthy knees and no past history of surgery took part in the study. For each participant, diagnostic ultrasound was utilized to collect three measurements: the patellofemoral joint space, the distance from the skin to the superficial patella, and distance from the skin to the patellar tendon. The Kinesio® Taping Space Correction Method was then applied. After a ten-minute waiting period in a non-weight bearing position, all three measurements were repeated. Each participant served as his or her own control. Paired t tests showed a statistically significant difference (mean difference = 1.1 mm, t [3,1]  = 2.823, p  = 0.008, g  = .465) between baseline and taped conditions in the space between the posterior surface of the patella to the medial femoral condyle. Neither the distance from the skin to the superficial patella nor the distance from the skin to the patellar tendon increased to a statistically significant degree. The application of the Kinesio® Taping Space Correction Method increases the patellofemoral joint space in healthy adults by increasing the distance between the patella and the medial femoral condyle, though it does not increase the distance from the skin to the superficial patella nor to the patellar tendon. 3.

  17. Tape functionality: position, change in shape, and outcome after TVT procedure--mid-term results.

    PubMed

    Kociszewski, Jacek; Rautenberg, Oliver; Kolben, Sebastian; Eberhard, Jakob; Hilgers, Reinhard; Viereck, Volker

    2010-07-01

    This study evaluates the relevance of the tape position and change in shape (tape functionality) under in vivo conditions for mid-term outcome. Changes in the sonographic tension-free vaginal tape (TVT) position relative to the percentage urethral length and the tape-urethra distance were determined after 6 and 48 months in 41 women with stress urinary incontinence. At 48 months, 76% (31/41) of women were cured, 17% (7/41) were improved, and 7% (3/41) were failures. Disturbed bladder voiding was present in 12% (5/41), de novo urge incontinence in 7% (3/41). The median TVT position was at 63% of urethral length. Median tape-urethra distance was 2.7 mm, ranging from 2.9 mm in continent patients without complications to 1.1 mm in those with obstructive complications. Patients with postoperative urine loss had a median distance of 3.9 mm. The tape was stretched at rest and C-shaped during straining in 15 of 41 women (37%) at 48 months (all continent). Patients with this tape functionality at 6 months were also cured at 48 months in 86% of cases (19/22), and only 14% (3/22) showed recurrent incontinence. Mid-term data suggest an optimal outcome if the tape is positioned at least 2 mm from the urethra at the junction of the middle and distal thirds. Patients with optimal tape functionality at 6 months are likely to show mid-term therapeutic success.

  18. Effects of a paraspinal-lumbar tape application during 7 days on the perceived area of tape contact.

    PubMed

    Funk, Stefan; Finke, Roy; Zeh, Stefan; Siebert, Tobias; Puta, Christian

    2017-05-01

    The study aimed to investigate the changes of the perceived area of tape contact during a lumbar tape application that lasted 7 days. Single group, repeated measures study. University research laboratory. Twenty-three healthy collegiate students in sports science. Perceived area of tape contact was collected by preparing a drawing of their individual perceived tape outline into a printed body image. Measurements were obtained immediately after fixation of the tape (day 0), at day 3 and day 7 during application and 5 min after the release of the application (day 7). There was no significant change of the perceived area of tape contact after 3 days of tape application. A significant decrease in the perceived area of tape contact was detected 7 days after application (p < 0.05) and after detaching the tape (p < 0.01) compared to the first measurement. Our results indicate that the perception of the area of tape contact of healthy sport students is decreased at 7 days. This effect could not be observed at 3 days. These results provide relevant information for the use of elastic tapes concerning the duration of application in medical therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. EFFECT OF ATHLETIC TAPING AND KINESIOTAPING® ON MEASUREMENTS OF FUNCTIONAL PERFORMANCE IN BASKETBALL PLAYERS WITH CHRONIC INVERSION ANKLE SPRAINS

    PubMed Central

    Karatas, Nihan; Baltaci, Gul

    2012-01-01

    Background: Chronic inversion ankle sprains are common in basketball players. The effect of taping on functional performance is disputed in the literature. Kinesiotaping® (KT®) is a new method that is being used as both a therapeutic and performance enhancement tool. To date, it appears that no study has investigated the effect of ankle KT® on functional performance. Purpose: To investigate the effects of different types of taping (KT® using Kinesio Tex®, athletic taping) on functional performance in athletes with chronic inversion sprains of the ankle. Study Design: Crossover Study Design Methods: Fifteen male basketball players with chronic inversion ankle sprains between the ages of 18 and 22 participated in this study. Functional performance tests (Hopping test by Amanda et al, Single Limb Hurdle Test, Standing Heel Rise test, Vertical Jump Test, The Star Excursion Balance Test [SEBT] and Kinesthetic Ability Trainer [KAT] Test) were used to quantify agility, endurance, balance, and coordination. These tests were conducted four times at one week intervals using varied conditions: placebo tape, without tape, standard athletic tape, and KT®. One-way ANOVA tests were used to examine difference in measurements between conditions. Bonferroni correction was applied to correct for repeated testing. Results: There were no significant differences among the results obtained using the four conditions for SEBT (anterior p=0.0699; anteromedial p=0.126; medial p=0.550; posteromedial p=0.587; posterior p=0.754; posterolateral p=0.907; lateral p=0.124; anterolateral p=0.963) and the KAT dynamic measurement (p=0.388). Faster performance times were measured with KT® and athletic tape in single limb hurdle test when compared to placebo and non-taped conditions (Athletic taping- placebo taping: p=0.03; athletic taping- non tape p=0.016;KT®- Placebo taping p=0.042; KT®-Non tape p=0.016). In standing heel rise test and vertical jump test, athletic taping led to decreased

  20. Short-term effects of kinesio tape on joint position sense, isokinetic measurements, and clinical parameters in patellofemoral pain syndrome

    PubMed Central

    Kurt, Emine Eda; Büyükturan, Öznur; Erdem, Hatice Rana; Tuncay, Figen; Sezgin, Hicabi

    2016-01-01

    [Purpose] To evaluate the short-term effects of kinesio tape on joint position sense, isokinetic measurements, kinesiophobia, symptoms, and functional limitations in patients with patellofemoral pain syndrome. [Subjects and Methods] A total of 90 patients (112 knees) with patellofemoral pain syndrome were randomized into a kinesio tape group (n=45) or placebo kinesio tape group (n=45). Baseline isokinetic quadriceps muscle tests and measurements of joint position sense were performed in both groups. Pain was measured with a Visual Analog Scale, kinesiophobia with the Tampa kinesiophobia scale, and symptoms and functional limitations with the Kujala pain scale. Measurements were repeated 2 days after kinesio tape application. [Results] No differences were found between baseline isokinetic muscle measurements and those taken 2 days after application. However, significant improvements were observed in the kinesio tape group, with regard to joint position sense, pain, kinesiophobia, symptoms, and functional limitations after treatment. Examination of the differences between pre- and post-treatment values in both groups revealed that the kinesio tape group demonstrated greater improvements compared to the placebo kinesio tape group. [Conclusion] Although short-term kinesio tape application did not increase hamstring muscle strength, it may have improved joint position sense, pain, kinesiophobia, symptoms, and daily limitations. PMID:27512259

  1. Ultrasound assessment of tension-free vaginal tape (TVT).

    PubMed

    Flock, F; Kohorst, F; Kreienberg, R; Reich, A

    2011-01-01

    To date, no standardization for the visualization of tension-free vaginal tape (TVT) has been established in clinical practice. The aim of this prospective observational study was to evaluate the shape and position of the tape using ultrasound and to compare this data with clinical postoperative results. In a three-year period, 296 patients with clinically and urodynamically proven stress urinary incontinence (SUI) were treated with TVT and received follow-up in our department. An additional 12 patients, who were initially treated in other hospitals and had postoperative problems, were included in this study. Depending on the outcome after 3 months, the patients were divided into groups with and without specific disorders. The TVT was evaluated by introital ultrasound. The position of the tape was established by its location in relation to the urethral length and the distance to the hypoechoic center of the urethra (HCU). A suitable TVT position was determined in patients without any postoperative disorders. The mean value for the TVT position at rest in relation to the urethral length was 61 %. The distance to the HCU was 4.6 ± 1.5 mm. In patients with persistent SUI, the tape was more often located under the inner (3 % vs. 0 %) or outer quarter (29 % vs. 13 %, p = 0.004). In patients with residual volume, the distance to the urethra was significantly lower (2.7 vs. 4.6, p < 0.001). TVT may be regularly investigated using ultrasound. In combination with the clinical outcome, it represents an important method of evaluating the tape and assists in the planning of a future therapeutic course of action in cases of postoperative problems. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Effect of athletic taping and kinesiotaping® on measurements of functional performance in basketball players with chronic inversion ankle sprains.

    PubMed

    Bicici, Seda; Karatas, Nihan; Baltaci, Gul

    2012-04-01

    Chronic inversion ankle sprains are common in basketball players. The effect of taping on functional performance is disputed in the literature. Kinesiotaping® (KT®) is a new method that is being used as both a therapeutic and performance enhancement tool. To date, it appears that no study has investigated the effect of ankle KT® on functional performance. To investigate the effects of different types of taping (KT® using Kinesio Tex®, athletic taping) on functional performance in athletes with chronic inversion sprains of the ankle. Crossover Study Design Fifteen male basketball players with chronic inversion ankle sprains between the ages of 18 and 22 participated in this study. Functional performance tests (Hopping test by Amanda et al, Single Limb Hurdle Test, Standing Heel Rise test, Vertical Jump Test, The Star Excursion Balance Test [SEBT] and Kinesthetic Ability Trainer [KAT] Test) were used to quantify agility, endurance, balance, and coordination. These tests were conducted four times at one week intervals using varied conditions: placebo tape, without tape, standard athletic tape, and KT®. One-way ANOVA tests were used to examine difference in measurements between conditions. Bonferroni correction was applied to correct for repeated testing. There were no significant differences among the results obtained using the four conditions for SEBT (anterior p=0.0699; anteromedial p=0.126; medial p=0.550; posteromedial p=0.587; posterior p=0.754; posterolateral p=0.907; lateral p=0.124; anterolateral p=0.963) and the KAT dynamic measurement (p=0.388). Faster performance times were measured with KT® and athletic tape in single limb hurdle test when compared to placebo and non-taped conditions (Athletic taping- placebo taping: p=0.03; athletic taping- non tape p=0.016;KT®- Placebo taping p=0.042; KT®-Non tape p=0.016). In standing heel rise test and vertical jump test, athletic taping led to decreased performance. (Standing heel rise test: Athletic taping

  3. Methods of Measuring Stress Relaxation in Composite Tape Springs

    DTIC Science & Technology

    2015-03-26

    plate in order to spread the load evenly and prevent excess torque . The plate also allows for force on the tape spring to be applied to the entire...aluminum squares that can be tightened to the base. The test fixture is secured to the marble base. The tape springs are folded in three locations with...top plate is pressed down by tightening the bolt on each nut. The tightening is complete when the tape spring just begins to create an M shape and

  4. Methods for tape fabrication of continuous filament composite parts and articles of manufacture thereof

    DOEpatents

    Weisberg, Andrew H

    2013-10-01

    A method for forming a composite structure according to one embodiment includes forming a first ply; and forming a second ply above the first ply. Forming each ply comprises: applying a bonding material to a tape, the tape comprising a fiber and a matrix, wherein the bonding material has a curing time of less than about 1 second; and adding the tape to a substrate for forming adjacent tape winds having about a constant distance therebetween. Additional systems, methods and articles of manufacture are also presented.

  5. Correlations between measurement time and different expansibility of the elastic tape on the rectus femoris and body sway index with plyometric exercise

    PubMed Central

    Yoon, Jung-Gyu

    2018-01-01

    [Purpose] The purpose of this study was to examine correlations between measurement time and different expansibility of the elastic tape on the rectus femoris and body sway index with plyometric exercise. [Subjects and Methods] The subjects of this study were 24 healthy men. C90 area, C90 angle, trace length, sway average velocity for body sway index were measured using a force plate by BT4. The collected data were analyzed using Kendall’s coefficient of concordance. [Results] All of body sway index on measuring follow up 24 hours after removing tape were significantly decreased than before and right after plyometric exercise. No significant correlations were found between body sway index and different expansibility of the elastic tape. [Conclusion] It appears that different expansibility of the elastic tape does not affect the ability to body sway index. Carry over effect of taping was verified on measuring follow up 24 hours after removing tape through the decreasing body sway index. PMID:29410564

  6. Correlations between measurement time and different expansibility of the elastic tape on the rectus femoris and body sway index with plyometric exercise.

    PubMed

    Yoon, Jung-Gyu

    2018-01-01

    [Purpose] The purpose of this study was to examine correlations between measurement time and different expansibility of the elastic tape on the rectus femoris and body sway index with plyometric exercise. [Subjects and Methods] The subjects of this study were 24 healthy men. C90 area, C90 angle, trace length, sway average velocity for body sway index were measured using a force plate by BT4. The collected data were analyzed using Kendall's coefficient of concordance. [Results] All of body sway index on measuring follow up 24 hours after removing tape were significantly decreased than before and right after plyometric exercise. No significant correlations were found between body sway index and different expansibility of the elastic tape. [Conclusion] It appears that different expansibility of the elastic tape does not affect the ability to body sway index. Carry over effect of taping was verified on measuring follow up 24 hours after removing tape through the decreasing body sway index.

  7. Certification of ICI 1012 optical data storage tape

    NASA Technical Reports Server (NTRS)

    Howell, J. M.

    1993-01-01

    ICI has developed a unique and novel method of certifying a Terabyte optical tape. The tape quality is guaranteed as a statistical upper limit on the probability of uncorrectable errors. This is called the Corrected Byte Error Rate or CBER. We developed this probabilistic method because of two reasons why error rate cannot be measured directly. Firstly, written data is indelible, so one cannot employ write/read tests such as used for magnetic tape. Secondly, the anticipated error rates need impractically large samples to measure accurately. For example, a rate of 1E-12 implies only one byte in error per tape. The archivability of ICI 1012 Data Storage Tape in general is well characterized and understood. Nevertheless, customers expect performance guarantees to be supported by test results on individual tapes. In particular, they need assurance that data is retrievable after decades in archive. This paper describes the mathematical basis, measurement apparatus and applicability of the certification method.

  8. Distance and Cable Length Measurement System

    PubMed Central

    Hernández, Sergio Elias; Acosta, Leopoldo; Toledo, Jonay

    2009-01-01

    A simple, economic and successful design for distance and cable length detection is presented. The measurement system is based on the continuous repetition of a pulse that endlessly travels along the distance to be detected. There is a pulse repeater at both ends of the distance or cable to be measured. The endless repetition of the pulse generates a frequency that varies almost inversely with the distance to be measured. The resolution and distance or cable length range could be adjusted by varying the repetition time delay introduced at both ends and the measurement time. With this design a distance can be measured with centimeter resolution using electronic system with microsecond resolution, simplifying classical time of flight designs which require electronics with picosecond resolution. This design was also applied to position measurement. PMID:22303169

  9. Use of binaural beat tapes for treatment of anxiety: a pilot study of tape preference and outcomes.

    PubMed

    Le Scouarnec, R P; Poirier, R M; Owens, J E; Gauthier, J; Taylor, A G; Foresman, P A

    2001-01-01

    Recent studies and anecdotal reports suggest that binaural auditory beats can affect mood, performance on vigilance tasks, and anxiety. To determine whether mildly anxious people would report decreased anxiety after listening daily for 1 month to tapes imbedded with tones that create binaural beats, and whether they would show a definite tape preference among 3 tapes. A 1-group pre-posttest pilot study. Patients' homes. A volunteer sample of 15 mildly anxious patients seen in the Clinique Psyché, Montreal, Quebec. Participants were asked to listen at least 5 times weekly for 4 weeks to 1 or more of 3 music tapes containing tones that produce binaural beats in the electroencephalogram delta/theta frequency range. Participants also were asked to record tape usage, tape preference, and anxiety ratings in a journal before and after listening to the tape or tapes. Anxiety ratings before and after tape listening, pre- and post-study State-Trait Anxiety Inventory scores, and tape preferences documented in daily journals. Listening to the binaural beat tapes resulted in a significant reduction in the anxiety score reported daily in patients' diaries. The number of times participants listened to the tapes in 4 weeks ranged from 10 to 17 (an average of 1.4 to 2.4 times per week) for approximately 30 minutes per session. End-of-study tape preferences indicated that slightly more participants preferred tape B, with its pronounced and extended patterns of binaural beats, over tapes A and C. Changes in pre- and posttest listening State-Trait Anxiety Inventory scores trended toward a reduction of anxiety, but these differences were not statistically significant. Listening to binaural beat tapes in the delta/theta electroencephalogram range may be beneficial in reducing mild anxiety. Future studies should account for music preference among participants and include age as a factor in outcomes, incentives to foster tape listening, and a physiologic measure of anxiety reduction. A

  10. A new ankle laxity tester and its use in the measurement of the effectiveness of taping.

    PubMed

    Kirk, T; Saha, S; Bowman, L S

    2000-12-01

    Damage to the lateral ligaments of the ankle, namely the anterior talofibular (ATFL) and the calcaneofibular (CFL) ligaments, is a frequently reported sports injury. The anterior drawer test is generally used to evaluate whether the ATFL has been torn, while the talar tilt test is used to determine if the CFL has been injured. Although these two manual tests are often utilized for quick diagnosis, they have been criticized because of their subjective nature and their inability to produce quantitative and reproducible results. A prototype ankle tester was manufactured that could measure the input force and torque, as well as the linear and angular deprivations for the anterior drawer test and the talar tilt test, respectively. This device was used to take readings on 10 human volunteers of a mean age of 21.6 years. This device was X-ray compatible, adjustable for varying patient sizes, relatively small, portable, and easy to operate. Testing was performed to determine how the stiffness of the ankle would respond to taping, and the effect of walking on the taped ankle. The overall mean anterior drawer was 5.93 mm and the mean talar tilt was 51.6 degrees for bare ankles using a force of 111 N (25 lbs) for the drawer and a torque of 16 N m for the tilt. Taping provided an average increase in stiffness of 11.3%, demonstrating that it did provide increased stability. However, statistically significant (P<0.05) decreases in the stiffness subsequent to taping were observed between the initially taped ankles and after 20 min of walking, when it was shown that talar tilt had increased. The prototype ankle tester produced repeatable measurements, and results show that the increase in stiffness due to taping did decrease after a short period of time.

  11. Tape transport mechanism

    DOEpatents

    Groh, Edward F.; McDowell, William; Modjeski, Norbert S.; Keefe, Donald J.; Groer, Peter

    1979-01-01

    A device is provided for transporting, in a stepwise manner, tape between a feed reel and takeup reel. An indexer moves across the normal path of the tape displacing it while the tape on the takeup reel side of the indexer is braked. After displacement, the takeup reel takes up the displaced tape while the tape on the feed reel side of the indexer is braked, providing stepwise tape transport in precise intervals determined by the amount of displacement caused by the indexer.

  12. Virtual tape measure for the operating microscope: system specifications and performance evaluation.

    PubMed

    Kim, M Y; Drake, J M; Milgram, P

    2000-01-01

    The Virtual Tape Measure for the Operating Microscope (VTMOM) was created to assist surgeons in making accurate 3D measurements of anatomical structures seen in the surgical field under the operating microscope. The VTMOM employs augmented reality techniques by combining stereoscopic video images with stereoscopic computer graphics, and functions by relying on an operator's ability to align a 3D graphic pointer, which serves as the end-point of the virtual tape measure, with designated locations on the anatomical structure being measured. The VTMOM was evaluated for its baseline and application performances as well as its application efficacy. Baseline performance was determined by measuring the mean error (bias) and standard deviation of error (imprecision) in measurements of non-anatomical objects. Application performance was determined by comparing the error in measuring the dimensions of aneurysm models with and without the VTMOM. Application efficacy was determined by comparing the error in selecting the appropriate aneurysm clip size with and without the VTMOM. Baseline performance indicated a bias of 0.3 mm and an imprecision of 0.6 mm. Application bias was 3.8 mm and imprecision was 2.8 mm for aneurysm diameter. The VTMOM did not improve aneurysm clip size selection accuracy. The VTMOM is a potentially accurate tool for use under the operating microscope. However, its performance when measuring anatomical objects is highly dependent on complex visual features of the object surfaces. Copyright 2000 Wiley-Liss, Inc.

  13. Distance Measurements In X-Ray Pictures

    NASA Astrophysics Data System (ADS)

    Forsgren, Per-Ola

    1987-10-01

    In this paper, a measurement method for the distance between binary objects will be presented. It has been developed for a specific purpose, the evaluation of rheumatic disease, but should be useful also in other applications. It is based on a distance map in the area between binary objects. A skeleton is extracted from the distance map by searching for local maxima. The distance measure is based on the average of skelton points in a defined measurement area. An objective criterion for selection of measurement points on the skeleton is proposed. Preliminary results indicate that good repeatability is attained.

  14. Effectiveness of functional ankle taping for judo athletes: a comparison between judo bandaging and taping.

    PubMed Central

    Yamamoto, T; Kigawa, A; Xu, T

    1993-01-01

    This study was conducted to compare the effectiveness of the traditional method of ankle bandaging and the new method of ankle taping for judo athletes in Japan, and to introduce a functionally effective taping method for judo players. Four university judo athletes with ankle instability were selected to undertake radiography of the ankles before and after exercise, with bandaging at one time and taping at the other. Talar tilt (TT) angles were measured in order to compare the ankle-supporting effects. The results showed that the old ankle bandaging method had no role in eliminating the talar tilt during judo practice. In contrast, the new taping method was more effective in eliminating the talar tilt and supporting the involved ankles both mechanically and functionally. Images Figure 1 Figure 2 Figure 3 PMID:8358580

  15. The efficacy of elastic therapeutic tape variations on measures of ankle function and performance.

    PubMed

    Brogden, Christopher Michael; Marrin, Kelly; Page, Richard Michael; Greig, Matt

    2018-04-23

    To investigate the effects of different variations of elastic therapeutic taping (ETT) on tests used to screen for ankle injury risk and function. Randomized crossover. Laboratory. Twelve professional male soccer players completed three experimental trials: No tape (NT), RockTape™ (RT), and Kinesio™ Tape (KT) applied to the ankle complex. Clinical and functional ankle screening tests were used to assess the effects of ETT on measures of joint position sense, postural stability and ground reaction forces. KT (P = 0.04) and RT (P = 0.01) demonstrated significant improvements in end range joint position sense. When compared to NT, RT significantly (P = 0.02) improved mid-range joint position sense at 15°, and time to complete a drop landing task. No significant differences were observed for measures of postural stability (P ≥ 0.12) nor ground reaction force variables (P ≥ 0.33). Results advocate the use of ETT for proprioceptive and functional tasks when applied to the ankles of healthy male soccer players. However, a greater number of practical and significant differences were observed when RT only was applied, indicating that practitioners may potentially advocate the use of RT for tasks requiring proprioception and functional performance. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  16. Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe

    PubMed Central

    Dresler, Maria Magdalena; Kociszewski, Jacek; Pędraszewski, Piotr; Trzeciak, Agnieszka; Surkont, Grzegorz

    2017-01-01

    Introduction Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling) is determined in relation to the urethra or the pubic symphysis. Aim of the study The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. Material and methods The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. Results The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. Conclusions Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes. PMID:28856017

  17. Tape tracking and handling for magnetic tape recorders. [aboard spacecraft

    NASA Technical Reports Server (NTRS)

    Paroby, W.; Disilvestre, R.

    1975-01-01

    One of the critical performance and life limiting elements of a spacecraft tape recorder instrumentation system which has received little attention in technical literature is magnetic tape tracking and handling technology. This technology is required to understand how to gently transfer tape from one reel to another with proper alignment and a desirable uniform velocity at the read and write transducer heads. The increased demand for high data rate (i.e., multi-track spacecraft recording instrumentation systems), coupled with performance under extreme environmental conditions, requires a thorough knowledge of the various parameters which establish an optimum designed tape tracking and handling system. Stress analysis techniques are required to evaluate these parameters substantiated with test tape tracking data, to show the effect of each parameter on a tape recorder instrumentation tracking system. The technology is applicable to ground type tape recorders where the detrimental effects of edge guidance can be eliminated.

  18. Five year magnetic tape for unattended satellite tape recorders

    NASA Technical Reports Server (NTRS)

    Benn, G. S. L.; Gutfreund, K.

    1972-01-01

    The development and fabrication of a quantity of long life magnetic tape with properties selected specifically for unattended operation in spacecraft tape recorders was studied. A detailed analytical consideration of various binder systems was undertaken. This included the chemical aspects of the binders, cohesion and adhesion effects, stability and the mechanical and physical properties. The ability to form free films of these polymers and their combination with various oxide loadings and other additives allowed a rapid selection of four polymer candidates for a five year magnetic tape. Samples were evaluated under actual running conditions which included physical, magnetic, and extensive life testing. These sample tapes withstood 50,000 bidirectional tape passes under fairly harsh operating conditions.

  19. Immediate Effects of Kinesiology Taping of Quadriceps on Motor Performance after Muscle Fatigued Induction.

    PubMed

    Ahn, Ick Keun; Kim, You Lim; Bae, Young-Hyeon; Lee, Suk Min

    2015-01-01

    Objectives. The purpose of this cross-sectional single-blind study was to investigate the immediate effects of Kinesiology taping of quadriceps on motor performance after muscle fatigued induction. Design. Randomized controlled cross-sectional design. Subjects. Forty-five subjects participated in this study. Participants were divided into three groups: Kinesiology taping group, placebo taping group, and nontaping group. Methods. Subjects performed short-term exercise for muscle fatigued induction, followed by the application of each intervention. Peak torque test, one-leg single hop test, active joint position sense test, and one-leg static balance test were carried out before and after the intervention. Results. Peak torque and single-leg hopping distance were significantly increased when Kinesiology taping was applied (p < 0.05). But there were no significant effects on active joint position sense and single-leg static balance. Conclusions. We proved that Kinesiology taping is effective in restoring muscle power reduced after muscle fatigued induction. Therefore, we suggest that Kinesiology taping is beneficial for fatigued muscles.

  20. Start-On-The-Part Transient Model for In-Situ Automated Tape Placement of Thermoplastic Composites

    NASA Technical Reports Server (NTRS)

    Costen, Robert c.; Marchello, Joseph M.

    1997-01-01

    Fabrication of a complex part by automated tape placement (ATP) can require starting up a new tape-end in the part interior, termed start-on-the-part. Careful thermal management of the starting transient is needed to achieve uniform crystallinity and inter-laminar weld strength - which is the objective of this modeling effort. The transient is modeled by a Fourier-Laplace transform solution of the time-dependent thermal transport equation in two spatial dimensions. The solution is subject to a quasi-steady approximation for the speed and length of the consolidation head. Sample calculations are done for the Langley ATP robot applying PEEK/carbon fiber composite and for two upgrades in robot performance. The head starts out almost at rest which meets an engineering requirement for accurate placement of the new tape-end. The head then rapidly accelerates until it reaches its steady state speed. This rapid acceleration, however, violates the quasi-steady approximation, so uniform weld strength and crystallinity during the starting transient are not actually achieved. The solution does give the elapsed time and distance from start-up to validity of the quasi-steady approximation - which quantifies the length of the non-uniform region. The elapsed time was always less than 0.1 s and the elapsed distance less than 1 cm. This quantification would allow the non-uniform region to be either trimmed away or compensated for in the design of a part. Such compensation would require experiments to measure the degree of non-uniformity, because the solution does not provide this information. The rapid acceleration suggests that the consolidation roller or belt be actively synchronized to avoid abrading the tape.

  1. Non-intrusive torque measurement for rotating shafts using optical sensing of zebra-tapes

    NASA Astrophysics Data System (ADS)

    Zappalá, D.; Bezziccheri, M.; Crabtree, C. J.; Paone, N.

    2018-06-01

    Non-intrusive, reliable and precise torque measurement is critical to dynamic performance monitoring, control and condition monitoring of rotating mechanical systems. This paper presents a novel, contactless torque measurement system consisting of two shaft-mounted zebra tapes and two optical sensors mounted on stationary rigid supports. Unlike conventional torque measurement methods, the proposed system does not require costly embedded sensors or shaft-mounted electronics. Moreover, its non-intrusive nature, adaptable design, simple installation and low cost make it suitable for a large variety of advanced engineering applications. Torque measurement is achieved by estimating the shaft twist angle through analysis of zebra tape pulse train time shifts. This paper presents and compares two signal processing methods for torque measurement: rising edge detection and cross-correlation. The performance of the proposed system has been proven experimentally under both static and variable conditions and both processing approaches show good agreement with reference measurements from an in-line, invasive torque transducer. Measurement uncertainty has been estimated according to the ISO GUM (Guide to the expression of uncertainty in measurement). Type A analysis of experimental data has provided an expanded uncertainty relative to the system full-scale torque of  ±0.30% and  ±0.86% for the rising edge and cross-correlation approaches, respectively. Statistical simulations performed by the Monte Carlo method have provided, in the worst case, an expanded uncertainty of  ±1.19%.

  2. Suppression of Systematic Errors of Electronic Distance Meters for Measurement of Short Distances

    PubMed Central

    Braun, Jaroslav; Štroner, Martin; Urban, Rudolf; Dvořáček, Filip

    2015-01-01

    In modern industrial geodesy, high demands are placed on the final accuracy, with expectations currently falling below 1 mm. The measurement methodology and surveying instruments used have to be adjusted to meet these stringent requirements, especially the total stations as the most often used instruments. A standard deviation of the measured distance is the accuracy parameter, commonly between 1 and 2 mm. This parameter is often discussed in conjunction with the determination of the real accuracy of measurements at very short distances (5–50 m) because it is generally known that this accuracy cannot be increased by simply repeating the measurement because a considerable part of the error is systematic. This article describes the detailed testing of electronic distance meters to determine the absolute size of their systematic errors, their stability over time, their repeatability and the real accuracy of their distance measurement. Twenty instruments (total stations) have been tested, and more than 60,000 distances in total were measured to determine the accuracy and precision parameters of the distance meters. Based on the experiments’ results, calibration procedures were designed, including a special correction function for each instrument, whose usage reduces the standard deviation of the measurement of distance by at least 50%. PMID:26258777

  3. Suppression of Systematic Errors of Electronic Distance Meters for Measurement of Short Distances.

    PubMed

    Braun, Jaroslav; Štroner, Martin; Urban, Rudolf; Dvoček, Filip

    2015-08-06

    In modern industrial geodesy, high demands are placed on the final accuracy, with expectations currently falling below 1 mm. The measurement methodology and surveying instruments used have to be adjusted to meet these stringent requirements, especially the total stations as the most often used instruments. A standard deviation of the measured distance is the accuracy parameter, commonly between 1 and 2 mm. This parameter is often discussed in conjunction with the determination of the real accuracy of measurements at very short distances (5-50 m) because it is generally known that this accuracy cannot be increased by simply repeating the measurement because a considerable part of the error is systematic. This article describes the detailed testing of electronic distance meters to determine the absolute size of their systematic errors, their stability over time, their repeatability and the real accuracy of their distance measurement. Twenty instruments (total stations) have been tested, and more than 60,000 distances in total were measured to determine the accuracy and precision parameters of the distance meters. Based on the experiments' results, calibration procedures were designed, including a special correction function for each instrument, whose usage reduces the standard deviation of the measurement of distance by at least 50%.

  4. Calibration tests on magnetic tape lightning current detectors

    NASA Technical Reports Server (NTRS)

    Crouch, K. E.

    1980-01-01

    The low cost, passive, peak lightning current detector (LCD) invented at the NASA/Kennedy Space Center, uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. Test results show that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10% were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. The stopwatch technique is a simple, low cost means of obtaining LCD readouts and can be used in the field to obtain immediate results. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result. If the shape of the conductor is other than circular (i.e., angle, channel, H-beam), an analysis of the magnetic field is required to use an LCD, especially at low current levels.

  5. Heterogeneity Measurement Based on Distance Measure for Polarimetric SAR Data

    NASA Astrophysics Data System (ADS)

    Xing, Xiaoli; Chen, Qihao; Liu, Xiuguo

    2018-04-01

    To effectively test the scene heterogeneity for polarimetric synthetic aperture radar (PolSAR) data, in this paper, the distance measure is introduced by utilizing the similarity between the sample and pixels. Moreover, given the influence of the distribution and modeling texture, the K distance measure is deduced according to the Wishart distance measure. Specifically, the average of the pixels in the local window replaces the class center coherency or covariance matrix. The Wishart and K distance measure are calculated between the average matrix and the pixels. Then, the ratio of the standard deviation to the mean is established for the Wishart and K distance measure, and the two features are defined and applied to reflect the complexity of the scene. The proposed heterogeneity measure is proceeded by integrating the two features using the Pauli basis. The experiments conducted on the single-look and multilook PolSAR data demonstrate the effectiveness of the proposed method for the detection of the scene heterogeneity.

  6. Thermal Edge-Effects Model for Automated Tape Placement of Thermoplastic Composites

    NASA Technical Reports Server (NTRS)

    Costen, Robert C.

    2000-01-01

    Two-dimensional thermal models for automated tape placement (ATP) of thermoplastic composites neglect the diffusive heat transport that occurs between the newly placed tape and the cool substrate beside it. Such lateral transport can cool the tape edges prematurely and weaken the bond. The three-dimensional, steady state, thermal transport equation is solved by the Green's function method for a tape of finite width being placed on an infinitely wide substrate. The isotherm for the glass transition temperature on the weld interface is used to determine the distance inward from the tape edge that is prematurely cooled, called the cooling incursion Delta a. For the Langley ATP robot, Delta a = 0.4 mm for a unidirectional lay-up of PEEK/carbon fiber composite, and Delta a = 1.2 mm for an isotropic lay-up. A formula for Delta a is developed and applied to a wide range of operating conditions. A surprise finding is that Delta a need not decrease as the Peclet number Pe becomes very large, where Pe is the dimensionless ratio of inertial to diffusive heat transport. Conformable rollers that increase the consolidation length would also increase Delta a, unless other changes are made, such as proportionally increasing the material speed. To compensate for premature edge cooling, the thermal input could be extended past the tape edges by the amount Delta a. This method should help achieve uniform weld strength and crystallinity across the width of the tape.

  7. The effect of kinesio taping in forward bending of the lumbar spine.

    PubMed

    Lemos, Thiago Vilela; Albino, Anna Carolina Gonçalves; Matheus, Joao Paulo C; Barbosa, Aurélio de Melo

    2014-09-01

    [Purpose] The aim of this study was to evaluate the influence of a lumbar fascia Kinesio Taping(®) technique forward bending range of motion. [Subjects and Methods] This was a longitudinal study with a randomized clinical trial composed of 39 subjects divided into three groups (control, Kinesio Without Tension-KWT, and Kinesio Fascia Correction-KFC). The subjects were assessed by Schober and fingertip-to-floor tests and left the tape in place for 48 hours before being reassessed 24 hours, 48 hours and 30 days after its removal. [Results] In all three experimental groups no significant differences were observed with the Schober test, but it was possible to observe an increase in lumbar flexion after 30 days. With the fingertip-to-floor distance assessment, the KFC and KWT groups showed significantly improved flexibility 24 hours and 48 hours after tape removal. [Conclusion] The Kinesio Taping(®) influenced fascia mobility, allowing for slight improvement of lumbar flexibility.

  8. The Effect of Kinesio Taping in Forward Bending of the Lumbar Spine

    PubMed Central

    Lemos, Thiago Vilela; Albino, Anna Carolina Gonçalves; Matheus, Joao Paulo C.; Barbosa, Aurélio de Melo

    2014-01-01

    [Purpose] The aim of this study was to evaluate the influence of a lumbar fascia Kinesio Taping® technique forward bending range of motion. [Subjects and Methods] This was a longitudinal study with a randomized clinical trial composed of 39 subjects divided into three groups (control, Kinesio Without Tension-KWT, and Kinesio Fascia Correction-KFC). The subjects were assessed by Schober and fingertip-to-floor tests and left the tape in place for 48 hours before being reassessed 24 hours, 48 hours and 30 days after its removal. [Results] In all three experimental groups no significant differences were observed with the Schober test, but it was possible to observe an increase in lumbar flexion after 30 days. With the fingertip-to-floor distance assessment, the KFC and KWT groups showed significantly improved flexibility 24 hours and 48 hours after tape removal. [Conclusion] The Kinesio Taping® influenced fascia mobility, allowing for slight improvement of lumbar flexibility. PMID:25276018

  9. [Laryngeal Tube Position Shift after Chest Compression: Comparison of Fixation Methods Using Durapore Tape, Multipore Tape, or a Neck Tape].

    PubMed

    Seno, Hisayo; Komasawa, Nobuyasu; Fujiwara, Shunsuke; Miyazaki, Shinichiro; Tatsumi, Shinichi; Minami, Toshiaki

    2015-05-01

    The laryngeal tube (LT ; Smiths Medical, Minnesota, U. S. A) is an inflatable supraglottic device for emergency airway management such as during chest compression, the instability after insertion remains a problem. We investigated the effectiveness of three fixation methods of LT using a manikin and automated chest compressor. After 10-minute chest compression, LT without fixation was shifted by 0.4 ± 0.1 cm, which was greater than with Durapore tape (0.2 ± 0.1 cm), Multipore tape (0.2 ± 0.1 cm), or a neck tape (0.1 ± 0.1 cm). The shift of the position was smaller with neck tape fixation compared to Durapore or Multipore tape fixation. A fixation neck tape may be useful in stabilizing the inserted position of LT during cardiopulmonary resuscitation.

  10. Antigenic Distance Measurements for Seasonal Influenza Vaccine Selection

    PubMed Central

    Cai, Zhipeng; Zhang, Tong; Wan, Xiu-Feng

    2011-01-01

    Influenza vaccination is one of the major options to counteract the effects of influenza diseases. Selection of an effective vaccine strain is the key to the success of an effective vaccination program since vaccine protection can only be achieved when the selected influenza vaccine strain matches the antigenic variants causing future outbreaks. Identification of an antigenic variant is the first step to determine whether vaccine strain needs to be updated. Antigenic distance derived from immunological assays, such as hemagglutination inhibition, is commonly used to measure the antigenic closeness between circulating strains and the current influenza vaccine strain. Thus, consensus on an explicit and robust antigenic distance measurement is critical in influenza surveillance. Based on the current seasonal influenza surveillance procedure, we propose and compare three antigenic distance measurements, including Average antigenic distance (A-distance), Mutual antigenic distance (M-distance), and Largest antigenic distance (L-distance). With the assistance of influenza antigenic cartography, our simulation results demonstrated that M-distance is a robust influenza antigenic distance measurement. Experimental results on both simulation and seasonal influenza surveillance data demonstrate that M-distance can be effectively utilized in influenza vaccine strain selection. PMID:22063385

  11. Tape reading fixture

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Commercially available roller type desk pad provides an efficient and orderly manner of handling rolled paper tapes for proofreading. The fixture, which is modified to accept Flex-O-Writer or similar tapes and roll them in either direction, reduces the chance of damaging or soiling the tapes through repeated handling.

  12. Thermoplastic tape compaction device

    DOEpatents

    Campbell, V.W.

    1994-12-27

    A device is disclosed for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite. 5 figures.

  13. Thermoplastic tape compaction device

    DOEpatents

    Campbell, Vincent W.

    1994-01-01

    A device for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite.

  14. Failure and fatigue characteristics of adhesive athletic tape.

    PubMed

    Bragg, Richard W; Macmahon, John M; Overom, Erin K; Yerby, Scott A; Matheson, Gordon O; Carter, Dennis R; Andriacchi, Thomas P

    2002-03-01

    Athletic tape has been commonly reported to lose much of its structural support after 20 min of exercise. Although many studies have addressed the functional performance characteristics of athletic tape, its mechanical properties are poorly understood. This study examines the failure and fatigue properties of several commonly used athletic tapes. A Web-based survey of professional sports trainers was used to select the following three tapes for the study: Zonas (Johnson & Johnson), Leukotape (Beiersdorf), and Jaylastic (Jaybird & Mais). Using a hydraulic material testing system (MTS), eight samples of each tape were compared in three different mechanical tests: load-to-failure, fatigue testing under load control, and fatigue testing under displacement control. Differences in tape microstructure were used to interpret the results of the mechanical tests. Significant differences (P < 0.001) in failure load, elongation at failure, and stiffness were found from failure tests. Significant differences were also found (P < 0.001) in fatigue behavior under both modes of control. As a representative example, in one normalized displacement control fatigue test after 20 min of cycling, 21% (Zonas), 29% (Leukotape), and 57% (Jaylastic) of the mechanical support was lost. After cycling, all tapes loaded to failure showed increased stiffness (P < 0.001), indicating significant energy absorption during cycling. Observed differences in the tapes' microstructure were qualitatively consistent with the measured differences in their mechanical properties. In understanding the shortcomings of currently available tapes, the results of these tests can now be used as benchmarks with which to compare and develop future tape designs. Ultimately, these improved tapes should reduce ankle injuries among athletes.

  15. Thermoplastic tape compaction device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, V.W.

    1994-12-27

    A device is disclosed for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin bandmore » of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite. 5 figures.« less

  16. PHOTOELECTRIC CONTROL FOR TAPE POSITIONING

    DOEpatents

    Woody, J.W. Jr.

    1961-07-25

    A control system is described for producing control impulses which may be used to start, stop, and position a magnetic tape with respect to a transducer, and to locate discrete areas on the tape. Means are provided for positive identification of data blocks, exact positioning of the tape under the magnetic head, drive in either direction, accurate skip-over of imperfect regions of the tape, stopping the tape if equipment malfunction results in a failure to detect the block-identifying signals, and starting and stopping those parts of the tape between of the tape drive clutches.

  17. The Carbon Monoxide Tape Recorder

    NASA Technical Reports Server (NTRS)

    Schoeberl, M. R.; Duncan, B. N.; Douglass, A. R.; Waters, J.; Livesey, N.; Read, W.; Filipiak, M.

    2006-01-01

    Using Aura MLS data we have identified the stratospheric tape recorder in carbon monoxide (CO). Unlike the water vapor tape recorder, which is controlled by upper troposphere processes, the CO tape recorder is linked to seasonal biomass burning. Since CO has a lifetime of only a few months, the CO tape recorder barely extends above 20 km. The tape head for CO appears to be close to 360K near the same location as the water vapor tape head [Read et al, 20041. Both tape heads are below the equatorial cold point tropopause but above the base of the tropical tropopause layer. The tape recorder signal becomes more distinct from 360K to 380K suggesting that convective detrainment of plays a decreasingly important role with altitude. The Global Modeling Initiative chemical transport model forced by the climatology of biomass burning reproduces the CO tape recorder.

  18. Kinesio® Tape Barrier Does Not Inhibit Intramuscular Cooling During Cryotherapy.

    PubMed

    Lyman, Katie J; McCrone, Michael; Hanson, Thomas A; Mellinger, Christopher D; Gange, Kara

    2018-05-29

    Allied health care professionals commonly apply cryotherapy as treatment for acute musculoskeletal trauma and the associated symptoms. Understanding the impact of a tape barrier on intramuscular temperature can assist in determining treatment duration for effective cryotherapy. To determine whether Kinesio® Tape acts as a barrier that affects intramuscular temperature during cryotherapy application. A repeated-measures, counterbalanced design in which the independent variable was tape application and the dependent variable was muscle temperature as measured by thermocouples placed 1 cm beneath the adipose layer. Additional covariates for robustness were BMI and adipose thickness. University research laboratory. 19 male college students with no contraindications to cryotherapy, no known sensitivity to Kinesio® Tape, and no reported quadriceps injury within the past six months. Topical cryotherapy: crushed-ice bags of 1 kg and 0.5 kg. Intramuscular temperature. The tape barrier had no statistically significant effect on muscle temperature. The pattern of temperature change was indistinguishable between participants with and without tape application. Findings suggest health care professionals can combine cryotherapy with a Kinesio® Tape application without any need for adjustments to cryotherapy duration.

  19. Portable digital pressure indicator for calibrating magnetic tape recorders

    NASA Technical Reports Server (NTRS)

    Mccormick, Royce F.; Leighty, Bradley D.

    1989-01-01

    The design of a portable Digital Pressure Indicator (DPI) to be used for calibrating the pressure systems on Langley's magnetic tape recorders is described. High-speed magnetic tape recorders require pressure (0 to 20 psig) for providing an air cushion across the tape guides and a slight vacuum (30 inch H2O) for maintaining the proper number of tape loops in the advance and feed chamber. The DPI is a hand-held device that can be quickly coupled to a magnetic tape recorder and includes a two-position switch for selecting either measured pressure or vacuum, to be displayed digitally in engineering units (psig or inches H2O). The DPI is currently in use in Langley's Analysis and Computation Division.

  20. Superconducting properties of multilayered Ag/Bi(Pb)-2223 tapes prepared using pretextured monolayered tapes

    NASA Astrophysics Data System (ADS)

    Syamaprasad, U.; Sarma, M. S.; Guruswamy, P.; Pillai, S. G. K.; Warrier, K. G. K.; Damodaran, A. D.

    1997-02-01

    Multilayered Ag/Bi(Pb)-2223 tapes with high critical current densities 0953-2048/10/2/005/img1 have been fabricated using partially heat treated, textured monolayered tapes. Cut sections of the monolayered tapes have been stacked one over the other and folded together using high-purity silver foil and further rolled and heat treated to obtain multilayered tapes of different thickness with an HTS layer thickness varying from 9 to 0953-2048/10/2/005/img2. A comparison of the superconducting properties of the multilayered tapes with those of monolayered tapes prepared under identical heat treatment conditions shows that the 0953-2048/10/2/005/img3 ratio at 77 K is as high as 0.57. The ratio is found to decrease with a decrease in the HTS core thickness of the multilayered tapes. XRD studies of `banana peeled' samples show that the monolayered tapes at the folding stage acquire a good degree of texturing. The relatively high value of the 0953-2048/10/2/005/img3 ratio obtained in the present case compared with those reported by the existing techniques is attributed to the use of pretextured monolayered tapes.

  1. Magnetic tape user guide

    NASA Technical Reports Server (NTRS)

    Evans, A. B.; Lee, L. L.

    1985-01-01

    This User Guide provides a general introduction to the structure, use, and handling of magnetic tapes at Langley Research Center (LaRC). The topics covered are tape terminology, physical characteristics, error prevention and detection, and creating, using, and maintaining tapes. Supplementary documentation is referenced where it might be helpful. The documentation is included for the tape utility programs, BLOCK, UNBLOCK, and TAPEDMP, which are available at the Central Scientific Computing Complex at LaRC.

  2. Performance measurements and operational characteristics of the Storage Tek ACS 4400 tape library with the Cray Y-MP EL

    NASA Technical Reports Server (NTRS)

    Hull, Gary; Ranade, Sanjay

    1993-01-01

    With over 5000 units sold, the Storage Tek Automated Cartridge System (ACS) 4400 tape library is currently the most popular large automated tape library. Based on 3480/90 tape technology, the library is used as the migration device ('nearline' storage) in high-performance mass storage systems. In its maximum configuration, one ACS 4400 tape library houses sixteen 3480/3490 tape drives and is capable of holding approximately 6000 cartridge tapes. The maximum storage capacity of one library using 3480 tapes is 1.2 TB and the advertised aggregate I/O rate is about 24 MB/s. This paper reports on an extensive set of tests designed to accurately assess the performance capabilities and operational characteristics of one STK ACS 4400 tape library holding approximately 5200 cartridge tapes and configured with eight 3480 tape drives. A Cray Y-MP EL2-256 was configured as its host machine. More than 40,000 tape jobs were run in a variety of conditions to gather data in the areas of channel speed characteristics, robotics motion, time taped mounts, and timed tape reads and writes.

  3. Absolute Distance Measurement with the MSTAR Sensor

    NASA Technical Reports Server (NTRS)

    Lay, Oliver P.; Dubovitsky, Serge; Peters, Robert; Burger, Johan; Ahn, Seh-Won; Steier, William H.; Fetterman, Harrold R.; Chang, Yian

    2003-01-01

    The MSTAR sensor (Modulation Sideband Technology for Absolute Ranging) is a new system for measuring absolute distance, capable of resolving the integer cycle ambiguity of standard interferometers, and making it possible to measure distance with sub-nanometer accuracy. The sensor uses a single laser in conjunction with fast phase modulators and low frequency detectors. We describe the design of the system - the principle of operation, the metrology source, beamlaunching optics, and signal processing - and show results for target distances up to 1 meter. We then demonstrate how the system can be scaled to kilometer-scale distances.

  4. Optical distance measurement device and method thereof

    DOEpatents

    Bowers, Mark W.

    2003-05-27

    A system and method of efficiently obtaining distance measurements of a target. A modulated optical beam may be used to determine the distance to the target. A first beam splitter may be used to split the optical beam and a second beam splitter may be used to recombine a reference beam with a return ranging beam. An optical mixing detector may be used in a receiver to efficiently detect distance measurement information.

  5. Personal miniature electrophysiological tape recorder

    NASA Astrophysics Data System (ADS)

    Green, H.

    1981-11-01

    The use of a personal miniature electrophysiological tape recorder to measure the physiological reactions of space flight personnel to space flight stress and weightlessness is described. The Oxford Instruments Medilog recorder, a battery-powered, four-channel cassette tape recorder with 24 hour endurance is carried on the person and will record EKG, EOG, EEG, and timing and event markers. The data will give information about heart rate and morphology changes, and document adaptation to zero gravity on the part of subjects who, unlike highly trained astronauts, are more representative of the normal population than were the subjects of previous space flight studies.

  6. Tape/head interface study

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Existing high energy tapes, high track density heads, and transport guidance techniques were evaluated and characterized to enable these technologies to be employed in future spacecraft recorders with high confidence. The results of these study efforts demonstrated tracking accuracy tape and head density that will support spacecraft recorders with data rates of a minimum of 150 Mbps and storage capacities ranging from 10 to the 10th to 10 to the 11th bits. Seven high energy tapes of either .25 in width, 1.00 in width, or both, were tested. All tapes were tested at the same speed (30 ips) and the same packing density (33 KBI). The performance of all 1 in tapes was considered superior.

  7. Measuring Contours of Coal-Seam Cuts

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Angle transducers measure angle between track sections as longwall shearer proceeds along coal face. Distance transducer functions in conjunction with angle transducers to obtain relative angles at known positions. When cut is complete, accumulated data are stored on cassette tape, and track profile is computed and displayed. Micro-processor-based instrument integrates small changes in angle and distance.

  8. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  9. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  10. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  11. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  12. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  13. Femtosecond frequency comb based distance measurement in air.

    PubMed

    Balling, Petr; Kren, Petr; Masika, Pavel; van den Berg, S A

    2009-05-25

    Interferometric measurement of distance using a femtosecond frequency comb is demonstrated and compared with a counting interferometer displacement measurement. A numerical model of pulse propagation in air is developed and the results are compared with experimental data for short distances. The relative agreement for distance measurement in known laboratory conditions is better than 10(-7). According to the model, similar precision seems feasible even for long-distance measurement in air if conditions are sufficiently known. It is demonstrated that the relative width of the interferogram envelope even decreases with the measured length, and a fringe contrast higher than 90% could be obtained for kilometer distances in air, if optimal spectral width for that length and wavelength is used. The possibility of comb radiation delivery to the interferometer by an optical fiber is shown by model and experiment, which is important from a practical point of view.

  14. Measuring Distances to Remote Galaxies and Quasars.

    ERIC Educational Resources Information Center

    McCarthy, Patrick J.

    1988-01-01

    Describes the use of spectroscopy and the redshift to measure how far an object is by measuring how fast it is receding from earth. Lists the most distant quasars yet found. Tables include "Redshift vs. Distance" and "Distances to Celestial Objects for Various Cosmologies." (CW)

  15. Magnetic Tape Recording for the Eighties

    NASA Technical Reports Server (NTRS)

    Kalil, Ford (Editor)

    1982-01-01

    The practical and theoretical aspects of state-of-the-art magnetic tape recording technology are reviewed. Topics covered include the following: (1) analog and digital magnetic tape recording, (2) tape and head wear, (3) wear testing, (4) magnetic tape certification, (5) care, handling, and management of magnetic tape, (6) cleaning, packing, and winding of magnetic tape, (7) tape reels, bands, and packaging, (8) coding techniques for high-density digital recording, and (9) tradeoffs of coding techniques.

  16. Kinesio taping or sham taping in knee osteoarthritis? A randomized, double-blind, sham-controlled trial.

    PubMed

    Kocyigit, Figen; Turkmen, Mehmet Besir; Acar, Merve; Guldane, Nezahat; Kose, Tugce; Kuyucu, Ersin; Erdil, Mehmet

    2015-11-01

    To compare effects of kinesio taping with sham taping at the end of 3 consecutive taping periods in knee osteoarthritis. 41 patients diagnosed with knee osteoarthritis according to American College of Rheumatology were randomized to receive either KT or sham taping. Baseline evaluations included a visual analog scale (VAS) for activity and nocturnal pain, Lequesne index for functional assessment and Nottingham Health Profile (NHP) for the quality of life. Taping was applied every four days, three times, and all of the assessments were repeated at the end of the treatment period. In both groups VAS for activity pain, VAS for nocturnal pain, Lequesne index score, NHP score decreased significantly. NHP energy scores were different significantly between the groups in favor of sham taping at the end of the 12-day period. Our findings indicate inconclusive evidence of a beneficial effect of kinesio taping over sham taping in knee osteoarthritis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Effect of Tape Burnishing and Drive Use on Head Wear in Rotary Tape Drives

    NASA Astrophysics Data System (ADS)

    Bhushan, Bharat; Anderson, Reid M.; Koinkar, Vilas N.

    Three types of 12.7-mm wide metal particle tapes were studied. One of the tapes was calendered, whereas the other two tapes were additionally burnished one or two times using a proprietary process. Each type of tape was studied after 100 passes in the BetaCam SP drive and also in the virgin (0 pass) state. It was reported that in the case of the unburnished tape, head wear was high in the first pass and decreased during use. However, head wear for the double burnished tape was low for the first pass and increased during use. Whereas in the single burnished tape, head wear was low in the first pass and remained low. The objective of this study is to understand the mechanisms for loss and growth of head wear by correlating the surface characteristics of the tapes to head wear rate and to determine the changes in the surface characteristics occurring from 0 to 100 passes in the drive. It was found that summit density, mean and rms summit height, and mean and rms summit curvature correlate well to the head wear data. During manufacture and use in the drive, as the summit density, mean and rms summit height, and mean and rms summit curvature decrease, the head wear rate decreases. The mechanism for head wear is the initial ploughing of dense, sharp and high tape asperities into the surface of the head material resulting in a high head wear rate and a high coefficient of friction. Double burnishing during manufacturing removes high asperities, thus making the tape very smooth and possibly results in high adhesion and head wear growth with use. Chemical changes of the tape surface during double burnishing (not part of this study) also may be responsible for head wear growth during use.

  18. Main image file tape description

    USGS Publications Warehouse

    Warriner, Howard W.

    1980-01-01

    This Main Image File Tape document defines the data content and file structure of the Main Image File Tape (MIFT) produced by the EROS Data Center (EDC). This document also defines an INQUIRY tape, which is just a subset of the MIFT. The format of the INQUIRY tape is identical to the MIFT except for two records; therefore, with the exception of these two records (described elsewhere in this document), every remark made about the MIFT is true for the INQUIRY tape.

  19. Arch-Taping Techniques for Altering Navicular Height and Plantar Pressures During Activity

    PubMed Central

    Newell, Tim; Simon, Janet; Docherty, Carrie L.

    2015-01-01

    Context Arch tapings have been used to support the arch by increasing navicular height. Few researchers have studied navicular height and plantar pressures after physical activity. Objective To determine if taping techniques effectively support the arch during exercise. Design Crossover study. Setting Athletic training research laboratory. Patients or Other Participants Twenty-five individuals (13 men, 12 women; age = 20.0 ± 1.0 years, height = 172.3 ± 6.6 cm, mass = 70.1 ± 10.2 kg) with a navicular drop of more than 8 mm (12.9 ± 3.3 mm) volunteered. Intervention(s) All individuals participated in 3 days of testing, with 1 day for each tape condition: no tape, low dye, and navicular sling. On each testing day, navicular height and plantar pressures were measured at 5 intervals: baseline; posttape; and after 5, 10, and 15 minutes of running. The order of tape condition was counterbalanced. Main Outcome Measure(s) The dependent variables were navicular height in millimeters and plantar pressures in kilopascals. Plantar pressures were divided into 5 regions: medial forefoot, lateral forefoot, lateral midfoot, lateral rearfoot, and medial rearfoot. Separate repeated-measures analyses of variance were conducted for each dependent variable. Results Navicular height was higher immediately after application of the navicular-sling condition (P = .004) but was reduced after 5 minutes of treadmill running (P = .12). We observed no differences from baseline to posttape for navicular height for the low-dye (P = .30) and no-tape conditions (P = .25). Both the low-dye and navicular-sling conditions increased plantar pressures in the lateral midfoot region compared with the no-tape condition. The low-dye condition created decreased pressure in the medial and lateral forefoot regions compared with the no-tape condition. All changes were identified immediately after application and were maintained during running. No changes were noted in plantar pressures for the no-tape

  20. Improved Apparatus for Measuring Distance Between Axles

    NASA Technical Reports Server (NTRS)

    Willard, Douglas E.; Townsend, Ivan I., III

    2003-01-01

    An improved version of an optoelectronic apparatus for measuring distances of the order of tens of feet with an error no larger than a small fraction of an inch (a few millimeters) has been built. Like the previous version, the present improved version of the apparatus is designed to measure the distance approximately equal to 66 ft (approximately equal to 20 m) between the axes of rotation of the front and rear tires of the space shuttle orbiter as it rests in a ground-based processing facility. Like the previous version, the present version could also be adapted for similar purposes in other settings: Examples include measuring perpendicular distance from a wall in a building, placement of architectural foundations, and general alignment and measurement operations.

  1. Recording and wear characteristics of 4 and 8 mm helical scan tapes

    NASA Technical Reports Server (NTRS)

    Peter, Klaus J.; Speliotis, Dennis E.

    1993-01-01

    Performance data of media on helical scan tape systems (4 and 8 mm) is presented and various types of media are compared. All measurements were performed on a standard MediaLogic model ML4500 Tape Evaluator System with a Flash Converter option for time based measurements. The 8 mm tapes are tested on an Exabyte 8200 drive and 4 mm tapes on an Archive Python drive; in both cases, the head transformer is directly connected to a Media Logic Read/Write circuit and test electronics. The drive functions only as a tape transport and its data recover circuits are not used. Signal to Noise, PW 50, Peak Shift and Wear Test data is used to compare the performance of MP (metal particle), BaFe, and metal evaporate (ME). ME tape is the clear winner in magnetic performance but its susceptibility to wear and corrosion, make it less than ideal for data storage.

  2. Effects of Kinesio taping and exercise on forward head posture.

    PubMed

    Shih, Hsu-Sheng; Chen, Shu-Shi; Cheng, Su-Chun; Chang, Hsun-Wen; Wu, Pei-Rong; Yang, Jin-Shiou; Lee, Yi-Shuang; Tsou, Jui-Yi

    2017-01-01

    Little is known about the effects of Kinesio taping and therapeutic exercise on correcting forward head posture. To compare Kinesio taping versus therapeutic exercise for forward head posture on static posture, dynamic mobility and functional outcomes. Sixty subjects (31 women, 29 men) with forward head postures participated in this study. They were randomly assigned to either one of the three groups: (1) exercise group (n = 20), (2) taping group (n = 20), and (3) control groups (n = 20). The horizontal forward displacement (HFD) between ear lobe and acromion process, upper cervical and lower cervical angle (UCA, LCA), active range of motion (AROM) of cervical spine, and neck disability index (NDI) were measured before and after a 5-week intervention, and a 2-week follow-up. Data were analyzed by means of a mixed design repeated-measures ANOVA. Both taping and exercise groups showed significant improvements in HFD compared with the control group at post-treatment and follow-up. Compared with the control group, the exercise group exhibited significant improvements in the LCA and the side bending AROM at post-treatment. Both Kinesio taping and therapeutic exercise improve forward head posture after intervention and a 2-week follow-up. The effectiveness of therapeutic exercise is better than taping.

  3. Kinesio Taping effects on knee extension force among soccer players.

    PubMed

    Serra, Maysa V G B; Vieira, Edgar R; Brunt, Denis; Goethel, Márcio F; Gonçalves, Mauro; Quemelo, Paulo R V

    2015-01-01

    Kinesio Taping (KT) is widely used, however the effects of KT on muscle activation and force are contradictory. To evaluate the effects of KT on knee extension force in soccer players. This is a clinical trial study design. Thirty-four subjects performed two maximal isometric voluntary contractions of the lower limbs pre, immediately post, and 24 hours after tape application on the lower limbs. Both lower limbs were taped, using K-Tape and 3M Micropore tape randomly on the right and left thighs of the participants. Isometric knee extension force was measured for dominant side using a strain gauge. The following variables were assessed: peak force, time to peak force, rate of force development until peak force, time to peak rate of force development, and 200 ms pulse. There were no statistically significant differences in the variables assessed between KT and Micropore conditions (F=0.645, p=0.666) or among testing sessions (pre, post, and 24h after) (F=0.528, p=0.868), and there was no statistical significance (F=0.271, p=0.986) for interaction between tape conditions and testing session. KT did not affect the force-related measures assessed immediately and 24 hours after the KT application compared with Micropore application, during maximal isometric voluntary knee extension.

  4. A Distance Measure for Genome Phylogenetic Analysis

    NASA Astrophysics Data System (ADS)

    Cao, Minh Duc; Allison, Lloyd; Dix, Trevor

    Phylogenetic analyses of species based on single genes or parts of the genomes are often inconsistent because of factors such as variable rates of evolution and horizontal gene transfer. The availability of more and more sequenced genomes allows phylogeny construction from complete genomes that is less sensitive to such inconsistency. For such long sequences, construction methods like maximum parsimony and maximum likelihood are often not possible due to their intensive computational requirement. Another class of tree construction methods, namely distance-based methods, require a measure of distances between any two genomes. Some measures such as evolutionary edit distance of gene order and gene content are computational expensive or do not perform well when the gene content of the organisms are similar. This study presents an information theoretic measure of genetic distances between genomes based on the biological compression algorithm expert model. We demonstrate that our distance measure can be applied to reconstruct the consensus phylogenetic tree of a number of Plasmodium parasites from their genomes, the statistical bias of which would mislead conventional analysis methods. Our approach is also used to successfully construct a plausible evolutionary tree for the γ-Proteobacteria group whose genomes are known to contain many horizontally transferred genes.

  5. Industrial Tape

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Scotch Brand Tape 364 was developed for NASA by 3M Company to protect electrical instrumentation coils and fluid lines from rocket launch blast conditions. It is an aluminized glass cloth tape which can withstand very high temperatures, is easily applied to compound surfaces, has excellent solar energy reflectance, and does not present an electrostatic hazard. It has potential automotive, transportation, and building construction applications.

  6. Nearest Neighbor Classification Using a Density Sensitive Distance Measurement

    DTIC Science & Technology

    2009-09-01

    both the proposed density sensitive distance measurement and Euclidean distance are compared on the Wisconsin Diagnostic Breast Cancer dataset and...proposed density sensitive distance measurement and Euclidean distance are compared on the Wisconsin Diagnostic Breast Cancer dataset and the MNIST...35 1. The Wisconsin Diagnostic Breast Cancer (WDBC) Dataset..........35 2. The

  7. Hygroscopic properties of magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Cuddihy, E. F.

    1976-01-01

    Relative humidity has been recognized as an important environmental factor in many head-tape interface phenomena such as headwear, friction, staining, and tape shed. Accordingly, the relative humidity is usually specified in many applications of tape use, especially when tape recorders are enclosed in hermetically sealed cases. Normally, the relative humidity is believed regulated by humidification of the fill gas to the specification relative humidity. This study demonstrates that the internal relative humidity in a sealed case is completely controlled by the time-dpendence of the hygroscopic properties of the pack of magnetic recording tape. Differences are found in the hygroscopic properties of the same brand of tape, which apparently result from aging, and which may have an effect on the long-term humidity-regulating behavior in a sealed case, and on the occurrence of head-tape interface phenomena from the long-term use of the tape. Results are presented on the basic hygroscopic properties of magnetic tape, its humidity-regulating behavior in a sealed case, and a theoretical commentary on the relative humidity dependence of head-wear by tape, is included.

  8. ICI optical data storage tape

    NASA Technical Reports Server (NTRS)

    Mclean, Robert A.; Duffy, Joseph F.

    1991-01-01

    Optical data storage tape is now a commercial reality. The world's first successful development of a digital optical tape system is complete. This is based on the Creo 1003 optical tape recorder with ICI 1012 write-once optical tape media. Several other optical tape drive development programs are underway, including one using the IBM 3480 style cartridge at LaserTape Systems. In order to understand the significance and potential of this step change in recording technology, it is useful to review the historical progress of optical storage. This has been slow to encroach on magnetic storage, and has not made any serious dent on the world's mountains of paper and microfilm. Some of the reasons for this are the long time needed for applications developers, systems integrators, and end users to take advantage of the potential storage capacity; access time and data transfer rate have traditionally been too slow for high-performance applications; and optical disk media has been expensive compared with magnetic tape. ICI's strategy in response to these concerns was to concentrate its efforts on flexible optical media; in particular optical tape. The manufacturing achievements, media characteristics, and media lifetime of optical media are discussed.

  9. Automated Tape Laying Machine for Composite Structures.

    DTIC Science & Technology

    The invention comprises an automated tape laying machine, for laying tape on a composite structure. The tape laying machine has a tape laying head...neatly cut. The automated tape laying device utilizes narrow width tape to increase machine flexibility and reduce wastage.

  10. The Broselow and Handtevy Resuscitation Tapes: A Comparison of the Performance of Pediatric Weight Prediction.

    PubMed

    Lowe, Calvin G; Campwala, Rashida T; Ziv, Nurit; Wang, Vincent J

    2016-08-01

    To assess the performance of two pediatric length-based tapes (Broselow and Handtevy) in predicting actual weights of US children. In this descriptive study, weights and lengths of children (newborn through 13 years of age) were extracted from the 2009-2010 National Health and Nutrition Examination Survey (NHANES). Using the measured length ranges for each tape and the NHANES-extracted length data, every case from the study sample was coded into Broselow and Handtevy zones. Mean weights were calculated for each zone and compared to the predicted Broselow and Handtevy weights using measures of bias, precision, and accuracy. A sub-sample was examined that excluded cases with body mass index (BMI)≥95th percentile. Weights of children longer than each tape also were examined. A total of 3,018 cases from the NHANES database met criteria. Although both tapes underestimated children's weight, the Broselow tape outperformed the Handtevy tape across most length ranges in measures of bias, precision, and accuracy of predicted weights relative to actual weights. Accuracy was higher in the Broselow tape for shorter children and in the Handtevy tape for taller children. Among the sub-sample with cases of BMI≥95th percentile removed, performance of the Handtevy tape improved, yet the Broselow tape still performed better. When assessing the weights of children who were longer than either tape, the actual mean weights did not approximate adult weights; although, those exceeding the Handtevy tape were closer. For pediatric weight estimation, the Broselow tape performed better overall than the Handtevy tape and more closely approximated actual weight. Lowe CG , Campwala RT , Ziv N , Wang VJ . The Broselow and Handtevy resuscitation tapes: a comparison of the performance of pediatric weight prediction. Prehosp Disaster Med. 2016;31(4):364-375.

  11. Comparison of gravimetric and spectroscopic approaches to quantify stratum corneum removed by tape-stripping.

    PubMed

    Mohammed, D; Yang, Q; Guy, R H; Matts, P J; Hadgraft, J; Lane, M E

    2012-09-01

    Skin surface tape-stripping is an extensively used technique to examine the distribution profile, penetration and safety of various active compounds. It is also a widely accepted method to probe skin barrier properties and more specifically, those of the stratum corneum (SC). The amount of SC removed by tape-stripping is generally determined either gravimetrically or by extraction and measurement of SC proteins. A novel infra-red densitometry (IRD) technique has recently been introduced to measure SC protein content. In the present study, IRD was investigated as an alternative method to measure the mass of SC removed by tape-stripping. Tape-stripping experiments were conducted on human volunteers. The weight of the stratum corneum removed was assessed by the gravimetric approach and by IRD. Transepidermal water loss (TEWL) was also measured before and after each tape-strip. A linear correlation coefficient was obtained for the data from the gravimetric and IRD measurements (r(2)=0.65; n=240). IRD is therefore proposed as a rapid, non-destructive alternative to the gravimetric approach to estimate the amount of SC removed by tape-stripping in vivo. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Gait Kinematics After Taping in Participants With Chronic Ankle Instability

    PubMed Central

    Chinn, Lisa; Dicharry, Jay; Hart, Joseph M.; Saliba, Susan; Wilder, Robert; Hertel, Jay

    2014-01-01

    Context: Chronic ankle instability is characterized by repetitive lateral ankle sprains. Prophylactic ankle taping is a common intervention used to reduce the risk of ankle sprains. However, little research has been conducted to evaluate the effect ankle taping has on gait kinematics. Objective: To investigate the effect of taping on ankle and knee kinematics during walking and jogging in participants with chronic ankle instability. Design: Controlled laboratory study. Setting: Motion analysis laboratory. Patients or Participants: A total of 15 individuals (8 men, 7 women; age = 26.9 ± 6.8 years, height = 171.7 ± 6.3 cm, mass = 73.5 ± 10.7 kg) with self-reported chronic ankle instability volunteered. They had an average of 5.3 ± 3.1 incidences of ankle sprain. Intervention(s): Participants walked and jogged in shoes on a treadmill while untaped and taped. The tape technique was a traditional preventive taping procedure. Conditions were randomized. Main Outcome Measure(s): Frontal-plane and sagittal-plane ankle and sagittal-plane knee kinematics were recorded throughout the entire gait cycle. Group means and 90% confidence intervals were calculated, plotted, and inspected for percentages of the gait cycle in which the confidence intervals did not overlap. Results: During walking, participants were less plantar flexed from 64% to 69% of the gait cycle (mean difference = 5.73° ± 0.54°) and less inverted from 51% to 61% (mean difference = 4.34° ± 0.65°) and 76% to 81% (mean difference = 5.55° ± 0.54°) of the gait cycle when taped. During jogging, participants were less dorsiflexed from 12% to 21% (mean difference = 4.91° ± 0.18°) and less inverted from 47% to 58% (mean difference = 6.52° ± 0.12°) of the gait cycle when taped. No sagittal-plane knee kinematic differences were found. Conclusions: In those with chronic ankle instability, taping resulted in a more neutral ankle position during walking and jogging in shoes on a treadmill. This change in

  13. Single-Image Distance Measurement by a Smart Mobile Device.

    PubMed

    Chen, Shangwen; Fang, Xianyong; Shen, Jianbing; Wang, Linbo; Shao, Ling

    2017-12-01

    Existing distance measurement methods either require multiple images and special photographing poses or only measure the height with a special view configuration. We propose a novel image-based method that can measure various types of distance from single image captured by a smart mobile device. The embedded accelerometer is used to determine the view orientation of the device. Consequently, pixels can be back-projected to the ground, thanks to the efficient calibration method using two known distances. Then the distance in pixel is transformed to a real distance in centimeter with a linear model parameterized by the magnification ratio. Various types of distance specified in the image can be computed accordingly. Experimental results demonstrate the effectiveness of the proposed method.

  14. Kinesio Taping effects on knee extension force among soccer players

    PubMed Central

    Serra, Maysa V. G. B.; Vieira, Edgar R.; Brunt, Denis; Goethel, Márcio F.; Gonçalves, Mauro; Quemelo, Paulo R. V.

    2015-01-01

    Background: Kinesio Taping (KT) is widely used, however the effects of KT on muscle activation and force are contradictory. Objective: To evaluate the effects of KT on knee extension force in soccer players. Method: This is a clinical trial study design. Thirty-four subjects performed two maximal isometric voluntary contractions of the lower limbs pre, immediately post, and 24 hours after tape application on the lower limbs. Both lower limbs were taped, using K-Tape and 3M Micropore tape randomly on the right and left thighs of the participants. Isometric knee extension force was measured for dominant side using a strain gauge. The following variables were assessed: peak force, time to peak force, rate of force development until peak force, time to peak rate of force development, and 200 ms pulse. Results: There were no statistically significant differences in the variables assessed between KT and Micropore conditions (F=0.645, p=0.666) or among testing sessions (pre, post, and 24h after) (F=0.528, p=0.868), and there was no statistical significance (F=0.271, p=0.986) for interaction between tape conditions and testing session. Conclusion: KT did not affect the force-related measures assessed immediately and 24 hours after the KT application compared with Micropore application, during maximal isometric voluntary knee extension. PMID:25789557

  15. Development of an in-fiber white-light interferometric distance sensor for absolute measurement of arbitrary small distances.

    PubMed

    Majumdar, Ayan; Huang, Haiying

    2008-05-20

    The fabrication, implementation, and evaluation of an in-fiber white-light interferometric distance sensor that is capable of measuring the absolute value of an arbitrary small distance are presented. Taking advantage of the mode-coupling effect of a long-period fiber grating, an additional cavity distance is added to the optical path difference of the distance sensor; therefore, it can generate a sufficient number of fringes for distance demodulation even if the free-space cavity distance is very small. It is experimentally verified that the distance sensor is capable of measuring small distances that are beyond the capability of a Fabry-Perot interferometric distance sensor.

  16. Tape recorder failure investigation

    NASA Technical Reports Server (NTRS)

    Higgins, M. D.; Loewenthal, S. H.; Carnahan, C. C.; Snyder, G. L.

    1996-01-01

    Two end-item tape recorders lost 4:1 mode data recording mode capability at less than half of their 1 6,000-cycle, 4-year operating life. Subsequent life tests on two spare recorders also experienced 4:1 mode data loss at 8,000 and 11,700 cycles. Tear down inspection after completion of the life tests showed that the tape had worn through the alfesil record and reproduce heads. An investigation was initiated to understand the cause of excessive tape head wear and the reasons why the 4:1 mode data rate, low-speed mode is more damaging than the 1:1 mode data rate, high-speed recording mode. The objective was to establish how operating conditions (tape speed, humidity, temperature, stop/start cycles) affects head life with the goal of extending head life on the remaining in-service tape recorders. Another interest was to explain why an earlier vendor life test showed capability beyond 16,000 cycles.

  17. Distance Measurement Solves Astrophysical Mysteries

    NASA Astrophysics Data System (ADS)

    2003-08-01

    Location, location, and location. The old real-estate adage about what's really important proved applicable to astrophysics as astronomers used the sharp radio "vision" of the National Science Foundation's Very Long Baseline Array (VLBA) to pinpoint the distance to a pulsar. Their accurate distance measurement then resolved a dispute over the pulsar's birthplace, allowed the astronomers to determine the size of its neutron star and possibly solve a mystery about cosmic rays. "Getting an accurate distance to this pulsar gave us a real bonanza," said Walter Brisken, of the National Radio Astronomy Observatory (NRAO) in Socorro, NM. Monogem Ring The Monogem Ring, in X-Ray Image by ROSAT satellite CREDIT: Max-Planck Institute, American Astronomical Society (Click on Image for Larger Version) The pulsar, called PSR B0656+14, is in the constellation Gemini, and appears to be near the center of a circular supernova remnant that straddles Gemini and its neighboring constellation, Monoceros, and is thus called the Monogem Ring. Since pulsars are superdense, spinning neutron stars left over when a massive star explodes as a supernova, it was logical to assume that the Monogem Ring, the shell of debris from a supernova explosion, was the remnant of the blast that created the pulsar. However, astronomers using indirect methods of determining the distance to the pulsar had concluded that it was nearly 2500 light-years from Earth. On the other hand, the supernova remnant was determined to be only about 1000 light-years from Earth. It seemed unlikely that the two were related, but instead appeared nearby in the sky purely by a chance juxtaposition. Brisken and his colleagues used the VLBA to make precise measurements of the sky position of PSR B0656+14 from 2000 to 2002. They were able to detect the slight offset in the object's apparent position when viewed from opposite sides of Earth's orbit around the Sun. This effect, called parallax, provides a direct measurement of

  18. Analysis of cache for streaming tape drive

    NASA Technical Reports Server (NTRS)

    Chinnaswamy, V.

    1993-01-01

    A tape subsystem consists of a controller and a tape drive. Tapes are used for backup, data interchange, and software distribution. The backup operation is addressed. During a backup operation, data is read from disk, processed in CPU, and then sent to tape. The processing speeds of a disk subsystem, CPU, and a tape subsystem are likely to be different. A powerful CPU can read data from a fast disk, process it, and supply the data to the tape subsystem at a faster rate than the tape subsystem can handle. On the other hand, a slow disk drive and a slow CPU may not be able to supply data fast enough to keep a tape drive busy all the time. The backup process may supply data to tape drive in bursts. Each burst may be followed by an idle period. Depending on the nature of the file distribution in the disk, the input stream to the tape subsystem may vary significantly during backup. To compensate for these differences and optimize the utilization of a tape subsystem, a cache or buffer is introduced in the tape controller. Most of the tape drives today are streaming tape drives. A streaming tape drive goes into reposition when there is no data from the controller. Once the drive goes into reposition, the controller can receive data, but it cannot supply data to the tape drive until the drive completes its reposition. A controller can also receive data from the host and send data to the tape drive at the same time. The relationship of cache size, host transfer rate, drive transfer rate, reposition, and ramp up times for optimal performance of the tape subsystem are investigated. Formulas developed will also show the advantages of cache watermarks to increase the streaming time of the tape drive, maximum loss due to insufficient cache, tradeoffs between cache and reposition times and the effectiveness of cache on a streaming tape drive due to idle times or interruptions due in host transfers. Several mathematical formulas are developed to predict the performance of the tape

  19. A Cognitively Grounded Measure of Pronunciation Distance

    PubMed Central

    Wieling, Martijn; Nerbonne, John; Bloem, Jelke; Gooskens, Charlotte; Heeringa, Wilbert; Baayen, R. Harald

    2014-01-01

    In this study we develop pronunciation distances based on naive discriminative learning (NDL). Measures of pronunciation distance are used in several subfields of linguistics, including psycholinguistics, dialectology and typology. In contrast to the commonly used Levenshtein algorithm, NDL is grounded in cognitive theory of competitive reinforcement learning and is able to generate asymmetrical pronunciation distances. In a first study, we validated the NDL-based pronunciation distances by comparing them to a large set of native-likeness ratings given by native American English speakers when presented with accented English speech. In a second study, the NDL-based pronunciation distances were validated on the basis of perceptual dialect distances of Norwegian speakers. Results indicated that the NDL-based pronunciation distances matched perceptual distances reasonably well with correlations ranging between 0.7 and 0.8. While the correlations were comparable to those obtained using the Levenshtein distance, the NDL-based approach is more flexible as it is also able to incorporate acoustic information other than sound segments. PMID:24416119

  20. Tape casting and partial melting of Bi-2212 thick films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buhl, D.; Lang, T.; Heeb, B.

    1994-12-31

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 {mu}m. The orientation of the (a,b)-plane of the grains were parallel to the substrate with a misalignment of less than 6{degrees}. At 77K/OT a critical current density ofmore » 15`000 A/cm{sup 2} was reached in films of the dimension 1cm x 2cm x 20{mu}m (1{mu}V/cm criterion, resistively measured). At 4K/OT the highest value was 350`000 A/cm{sup 2} (1nV/cm criterion, magnetically measured).« less

  1. Tape casting and partial melting of Bi-2212 thick films

    NASA Technical Reports Server (NTRS)

    Buhl, D.; Lang, TH.; Heeb, B.; Gauckler, L. J.

    1995-01-01

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 microns. The orientation of the (a,b)-plane of the grains was parallel to the substrate with a misalignment of less than 6 deg. At 77 K/0T a critical current density of 15, 000 A/sq cm was reached in films of the dimension 1 cm x 2 cm x 20 microns (1 micron V/cm criterion, resistively measured). At 4 K/0T the highest value was 350,000 A/sq cm (1 nV/cm criterion, magnetically measured).

  2. Krytox Lubrication Tape Study. [fluorinated lubricating oil for video tape recorders

    NASA Technical Reports Server (NTRS)

    Lee, F.

    1978-01-01

    The use of Krytox, a fluorinated oil, as a tape surface lubricant was studied for a wideband video tape recorder. In spite of the 5 to 1 head wear reduction credited to the surface lubricant, the resultant head life fell short of the 1500 hour goal.

  3. Optical Distance Measurement Device And Method Thereof

    DOEpatents

    Bowers, Mark W.

    2004-06-15

    A system and method of efficiently obtaining distance measurements of a target by scanning the target. An optical beam is provided by a light source and modulated by a frequency source. The modulated optical beam is transmitted to an acousto-optical deflector capable of changing the angle of the optical beam in a predetermined manner to produce an output for scanning the target. In operation, reflected or diffused light from the target may be received by a detector and transmitted to a controller configured to calculate the distance to the target as well as the measurement uncertainty in calculating the distance to the target.

  4. Digital tape unit test facility software

    NASA Technical Reports Server (NTRS)

    Jackson, J. T.

    1971-01-01

    Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

  5. Measuring cross sections using a sag tape: a generalized procedure

    Treesearch

    Gary A. Ray; Walter F. Megahan

    1979-01-01

    A procedure was developed for surveying cross sections using a sag tape with unequal end elevations. The procedure is as accurate as traditional engineer's level surveys, is faster and easier, and can be programed for a digital computer by following the flow diagram which is provided.

  6. Distance measurement using frequency scanning interferometry with mode-hoped laser

    NASA Astrophysics Data System (ADS)

    Medhat, M.; Sobee, M.; Hussein, H. M.; Terra, O.

    2016-06-01

    In this paper, frequency scanning interferometry is implemented to measure distances up to 5 m absolutely. The setup consists of a Michelson interferometer, an external cavity tunable diode laser, and an ultra-low expansion (ULE) Fabry-Pérot (FP) cavity to measure the frequency scanning range. The distance is measured by acquiring simultaneously the interference fringes from, the Michelson and the FP interferometers, while scanning the laser frequency. An online fringe processing technique is developed to calculate the distance from the fringe ratio while removing the parts result from the laser mode-hops without significantly affecting the measurement accuracy. This fringe processing method enables accurate distance measurements up to 5 m with measurements repeatability ±3.9×10-6 L. An accurate translation stage is used to find the FP cavity free-spectral-range and therefore allow accurate measurement. Finally, the setup is applied for the short distance calibration of a laser distance meter (LDM).

  7. Quick-release medical tape

    PubMed Central

    Laulicht, Bryan; Langer, Robert; Karp, Jeffrey M.

    2012-01-01

    Medical tape that provides secure fixation of life-sustaining and -monitoring devices with quick, easy, damage-free removal represents a longstanding unmet medical need in neonatal care. During removal of current medical tapes, crack propagation occurs at the adhesive–skin interface, which is also the interface responsible for device fixation. By designing quick-release medical tape to undergo crack propagation between the backing and adhesive layers, we decouple removal and device fixation, enabling dual functionality. We created an ordered adhesive/antiadhesive composite intermediary layer between the medical tape backing and adhesive for which we achieve tunable peel removal force, while maintaining high shear adhesion to secure medical devices. We elucidate the relationship between the spatial ordering of adhesive and antiadhesive regions to create a fully tunable system that achieves strong device fixation and quick, easy, damage-free device removal. We also described ways of neutralizing the residual adhesive on the skin and have observed that thick continuous films of adhesive are easier to remove than the thin islands associated with residual adhesive left by current medical tapes. PMID:23112196

  8. Tracer sensitive tapes

    NASA Technical Reports Server (NTRS)

    Burrows, W. H.; Burrows, W. H.

    1971-01-01

    A leak detection system has been developed, consisting of a tape that can be wrapped around possible leak sites on a system pressurized with air or gaseous nitrogen. Carbon monoxide, at a level of 100 to 1000 parts per million is used as a trace gas in the pressurized system. The sensitive element of the tape is palladium chloride supported on specially prepared silica gel and specially dried. At a CO level of 100 ppm and a leak rate of 10-20 ml/hr, discoloration of the sensitive element is observed in 1.5 to 3 min. The tape and trace gas are compatible with aerospace hardware, safe to handle, and economically reasonable to produce and handle.

  9. Effects of kinesio tape to reduce hand edema in acute stroke.

    PubMed

    Bell, Alison; Muller, Melissa

    2013-01-01

    The purpose of the study was to evaluate the effi cacy of Kinesio Tape (Kinesio USA, Albequerque, NM) for reducing hand edema in individuals with hemiplegia post stroke. Seventeen individuals who experienced acute stroke were screened for visual signs of edema and were randomly assigned to experimental and control groups. The experimental group received Kinesio Tape that was applied to hand and forearm for 6 days in combination with standard therapy; the control group received standard therapy. Blinded raters assessed edema reduction via circumferential measurements. Application of Kinesio Tape did not result in statistically signifi cant reduction in edema. Large and medium effect sizes were seen for edema reduction at the metacarpophalangeal and wrist joints, respectively, with Kinesio Tape. Further research is warranted to investigate the utility of Kinesio Tape in edema reduction.

  10. Measures of lexical distance between languages

    NASA Astrophysics Data System (ADS)

    Petroni, Filippo; Serva, Maurizio

    2010-06-01

    The idea of measuring distance between languages seems to have its roots in the work of the French explorer Dumont D’Urville (1832) [13]. He collected comparative word lists for various languages during his voyages aboard the Astrolabe from 1826 to 1829 and, in his work concerning the geographical division of the Pacific, he proposed a method for measuring the degree of relation among languages. The method used by modern glottochronology, developed by Morris Swadesh in the 1950s, measures distances from the percentage of shared cognates, which are words with a common historical origin. Recently, we proposed a new automated method which uses the normalized Levenshtein distances among words with the same meaning and averages on the words contained in a list. Recently another group of scholars, Bakker et al. (2009) [8] and Holman et al. (2008) [9], proposed a refined version of our definition including a second normalization. In this paper we compare the information content of our definition with the refined version in order to decide which of the two can be applied with greater success to resolve relationships among languages.

  11. Modeling individual tree growth by fusing diameter tape and increment core data

    Treesearch

    Erin M. Schliep; Tracy Qi Dong; Alan E. Gelfand; Fan. Li

    2014-01-01

    Tree growth estimation is a challenging task as difficulties associated with data collection and inference often result in inaccurate estimates. Two main methods for tree growth estimation are diameter tape measurements and increment cores. The former involves repeatedly measuring tree diameters with a cloth or metal tape whose scale has been adjusted to give diameter...

  12. Analysis of transient state in HTS tapes under ripple DC load current

    NASA Astrophysics Data System (ADS)

    Stepien, M.; Grzesik, B.

    2014-05-01

    The paper concerns the analysis of transient state (quench transition) in HTS tapes loaded with the current having DC component together with a ripple component. Two shapes of the ripple were taken into account: sinusoidal and triangular. Very often HTS tape connected to a power electronic current supply (i.e. superconducting coil for SMES) that delivers DC current with ripples and it needs to be examined under such conditions. Additionally, measurements of electrical (and thermal) parameters under such ripple excitation is useful to tape characterization in broad range of load currents. The results presented in the paper were obtained using test bench which contains programmable DC supply and National Instruments data acquisition system. Voltage drops and load currents were measured vs. time. Analysis of measured parameters as a function of the current was used to tape description with quench dynamics taken into account. Results of measurements were also used to comparison with the results of numerical modelling based on FEM. Presented provisional results show possibility to use results of measurements in transient state to prepare inverse models of superconductors and their detailed numerical modelling.

  13. Enhancing contrast of fingerprints on plastic tape.

    PubMed

    Steele, Charles A; Ball, Mikki S

    2003-11-01

    Many of the currently available fingerprinting methods have limited ability to visualize fingerprints on plastic tape without expensive equipment or significant handling of the sample. This is especially true for visualizing fingerprints on black electrical tape. This study sought a hands-off method to produce easy visualization of fingerprints on different types of plastic tape, including black electrical tape, without the need for expensive equipment. The methods selected were to sublime disperse dyes into the tape, both with and without the fuming of cyanoacrylate, everywhere except for where the fingerprint was applied. The resulting color contrasts provided enough differentiation to visualize fingerprints on plastic tape under ambient light. Sequential fuming with cyanoacrylate followed by disperse dyes provided the best visualizations on all tapes, and cyanoacrylate followed by disperse yellow 211 clearly visualized fingerprints on black electrical tape.

  14. EROS to universal tape conversion processor

    NASA Technical Reports Server (NTRS)

    Obrien, S. O. (Principal Investigator)

    1980-01-01

    The function of the EROS processor is to allow a user to select a specific area from a full frame LANDSAT image which is written on tape in the EROS format. The area of interest is read from the EROS formatted tape and converted to the JSC Universal format and written onto another tape. This tape can then be read by the IMDACS processing system and normal analysis can be performed.

  15. Ankle taping does not impair performance in jump or balance tests.

    PubMed

    Abián-Vicén, Javier; Alegre, Luis M; Fernández-Rodríguez, J Manuel; Lara, Amador J; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96). The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed. Key pointsAnkle taping has no influence on balance performance.Ankle taping does not impair performance during the push-off phase of the jump.Ankle taping could increase the risk of injury during landings by increasing peak forces.

  16. Ankle Taping Does Not Impair Performance in Jump or Balance Tests

    PubMed Central

    Abián-Vicén, Javier; Alegre, Luis M.; Fernández-Rodríguez, J. Manuel; Lara, Amador J.; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96). The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed. Key pointsAnkle taping has no influence on balance performance.Ankle taping does not impair performance during the push-off phase of the jump.Ankle taping could increase the risk of injury during landings by increasing peak forces. PMID:24149902

  17. ICI optical data storage tape

    NASA Technical Reports Server (NTRS)

    Mclean, Robert A.; Duffy, Joseph F.

    1992-01-01

    Optical data storage tape is now a commercial reality. The world's first successful development of a digital optical tape system is complete. This is based on the Creo 1003 optical tape recorder with ICI 1012 write-once optical tape media. Flexible optical media offers many benefits in terms of manufacture; for a given capital investment, continuous, web-coating techniques produce more square meters of media than batch coating. The coated layers consist of a backcoat on the non-active side; on the active side there is a subbing layer, then reflector, dye/polymer, and transparent protective overcoat. All these layers have been tailored for ease of manufacture and specific functional characteristics.

  18. Contact Analog/Compressed Symbology Heading Tape Assessment

    NASA Technical Reports Server (NTRS)

    Shively, R. Jay; Atencio, Adolph; Turpin, Terry; Dowell, Susan

    2002-01-01

    A simulation assessed the performance, handling qualities and workload associated with a contact-analog, world-referenced heading tape as implemented on the Comanche Helmet Integrated Display Sight System (HIDSS) when compared with a screen-fixed, compressed heading tape. Six pilots, four active duty Army Aviators and two civilians flew three ADS-33 maneuvers and a traffic pattern in the Ames Vertical Motion Simulation facility. Small, but statistically significant advantages were found for the compressed symbology for handling qualities, workload, and some of the performance measures. It should be noted however that the level of performance and handling qualities for both symbology sets fell within the acceptable tolerance levels. Both symbology sets yield satisfactory handling qualities and performance in velocity stabilization mode and adequate handling qualities in the automatic flight control mode. Pilot comments about the contact analog symbology highlighted the lack of useful rate of change information in the heading tape and "blurring" due to the rapid movement of the heading tape. These issues warrant further study. Care must be taken in interpreting the operational significance of these results. The symbology sets yielded categorically similar data, i.e., acceptable handling qualities and adequate performance, so while the results point to the need for further study, their operational significance has yet to be determined.

  19. Comparative evaluation of ultrasound scanner accuracy in distance measurement

    NASA Astrophysics Data System (ADS)

    Branca, F. P.; Sciuto, S. A.; Scorza, A.

    2012-10-01

    The aim of the present study is to develop and compare two different automatic methods for accuracy evaluation in ultrasound phantom measurements on B-mode images: both of them give as a result the relative error e between measured distances, performed by 14 brand new ultrasound medical scanners, and nominal distances, among nylon wires embedded in a reference test object. The first method is based on a least squares estimation, while the second one applies the mean value of the same distance evaluated at different locations in ultrasound image (same distance method). Results for both of them are proposed and explained.

  20. Measurement of lidocaine and 2,6-dimethylaniline in minipig plasma, skin, and dermal tapes using UHPLC with electrospray MS/MS.

    PubMed

    Li, Qian; Magers, Tobias; King, Brad; Engel, Brian J; Bakhtiar, Ray; Green, Charisse; Shoup, Ronald

    2018-06-15

    Sensitive LC-MS/MS methods were developed to measure lidocaine and its metabolite 2,6-dimethylaniline (2,6-DMA) with application to transdermal studies. The methods for lidocaine in minipig plasma, tissue biopsies, and dermal tapes utilized mixed mode/SCX solid phase extraction, with lower quantitation limits of 25 pg/mL in plasma, 15 ng/g tissue, and 5 ng/tape. 2,6-DMA was measured in plasma and skin tissue homogenates by ultrafiltration and (for tissue) by further derivatization with 4-methoxybenzoyl chloride to form the corresponding benzamide derivative, which extended the lower limit of quantitation to 200 pg/mL. The methods allowed local measurement of lidocaine in stratum corneum, punch biopsies, and plasma and of 2,6-DMA in plasma and biopsies obtained from minipigs dosed with experimental transdermal formulations. Quantitation limits were approximately 7-fold lower than previously reported for lidocaine and 3-fold lower for 2,6-DMA. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Fabrication of high edge-definition steel-tape gratings for optical encoders.

    PubMed

    Ye, Guoyong; Liu, Hongzhong; Yan, Jiawei; Ban, Yaowen; Fan, Shanjin; Shi, Yongsheng; Yin, Lei

    2017-10-01

    High edge definition of a scale grating is the basic prerequisite for high measurement accuracy of optical encoders. This paper presents a novel fabrication method of steel tape gratings using graphene oxide nanoparticles as anti-reflective grating strips. Roll-to-roll nanoimprint lithography is adopted to manufacture the steel tape with hydrophobic and hydrophilic pattern arrays. Self-assembly technology is employed to obtain anti-reflective grating strips by depositing the graphene oxide nanoparticles on hydrophobic regions. A thin SiO 2 coating is deposited on the grating to protect the grating strips. Experimental results confirm that the proposed fabrication process enables a higher edge definition in making steel-tape gratings, and the new steel tape gratings offer better performance than conventional gratings.

  2. Fabrication of high edge-definition steel-tape gratings for optical encoders

    NASA Astrophysics Data System (ADS)

    Ye, Guoyong; Liu, Hongzhong; Yan, Jiawei; Ban, Yaowen; Fan, Shanjin; Shi, Yongsheng; Yin, Lei

    2017-10-01

    High edge definition of a scale grating is the basic prerequisite for high measurement accuracy of optical encoders. This paper presents a novel fabrication method of steel tape gratings using graphene oxide nanoparticles as anti-reflective grating strips. Roll-to-roll nanoimprint lithography is adopted to manufacture the steel tape with hydrophobic and hydrophilic pattern arrays. Self-assembly technology is employed to obtain anti-reflective grating strips by depositing the graphene oxide nanoparticles on hydrophobic regions. A thin SiO2 coating is deposited on the grating to protect the grating strips. Experimental results confirm that the proposed fabrication process enables a higher edge definition in making steel-tape gratings, and the new steel tape gratings offer better performance than conventional gratings.

  3. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, Eric B.; Muller, Albert C.

    1984-01-01

    A high voltage oil-impregnated electrical cable with fully polymer taped insulation operable to 765 kV. Biaxially oriented, specially processed, polyethylene, polybutene or polypropylene tape with an embossed pattern is wound in multiple layers over a conductive core with a permeable screen around the insulation. Conventional oil which closely matches the dielectric constant of the tape is used, and the cable can be impregnated after field installation because of its excellent impregnation characteristics.

  4. Kinematics of Tape Recording.

    ERIC Educational Resources Information Center

    Coleman, J. J.

    1982-01-01

    Describes mathematics of the nonliner relationships between a constant-speed, capstan-driven magnetic tape transport mechanism and a constant-angular-velocity take-up reel. The relationship, derived from the sum of a partial, serves in recognition of a finite tape. Thickness can serve as an example of rotational kinematics. (Author/SK)

  5. Light-Curing Adhesive Repair Tapes

    NASA Technical Reports Server (NTRS)

    Allred, Ronald; Haight, Andrea Hoyt

    2009-01-01

    Adhesive tapes, the adhesive resins of which can be cured (and thereby rigidized) by exposure to ultraviolet and/or visible light, are being developed as repair patch materials. The tapes, including their resin components, consist entirely of solid, low-outgassing, nonhazardous or minimally hazardous materials. They can be used in air or in vacuum and can be cured rapidly, even at temperatures as low as -20 C. Although these tapes were originally intended for use in repairing structures in outer space, they can also be used on Earth for quickly repairing a wide variety of structures. They can be expected to be especially useful in situations in which it is necessary to rigidize tapes after wrapping them around or pressing them onto the parts to be repaired.

  6. Tack Measurements of Prepreg Tape at Variable Temperature and Humidity

    NASA Technical Reports Server (NTRS)

    Wohl, Christopher; Palmieri, Frank L.; Forghani, Alireza; Hickmott, Curtis; Bedayat, Houman; Coxon, Brian; Poursartip, Anoush; Grimsley, Brian

    2017-01-01

    NASA’s Advanced Composites Project has established the goal of achieving a 30 percent reduction in the timeline for certification of primary composite structures for application on commercial aircraft. Prepreg tack is one of several critical parameters affecting composite manufacturing by automated fiber placement (AFP). Tack plays a central role in the prevention of wrinkles and puckers that can occur during AFP, thus knowledge of tack variation arising from a myriad of manufacturing and environmental conditions is imperative for the prediction of defects during AFP. A full design of experiments was performed to experimentally characterize tack on 0.25-inch slit-tape tow IM7/8552-1 prepreg using probe tack testing. Several process parameters (contact force, contact time, retraction speed, and probe diameter) as well as environmental parameters (temperature and humidity) were varied such that the entire parameter space could be efficiently evaluated. Mid-point experimental conditions (i.e., parameters not at either extrema) were included to enable prediction of curvature in relationships and repeat measurements were performed to characterize experimental error. Collectively, these experiments enable determination of primary dependencies as well as multi-parameter relationships. Slit-tape tow samples were mounted to the bottom plate of a rheometer parallel plate fixture using a jig to prevent modification of the active area to be interrogated with the top plate, a polished stainless steel probe, during tack testing. The probe surface was slowly brought into contact with the pre-preg surface until a pre-determined normal force was achieved (2-30 newtons). After a specified dwell time (0.02-10 seconds), during which the probe substrate interaction was maintained under displacement control, the probe was retracted from the surface (0.1-50 millimeters per second). Initial results indicated a clear dependence of tack strength on several parameters, with a particularly

  7. FGGE/ERBZ tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The FGGE/ERBZ tape contains 5 parameters which are extracted and reformatted from the Nimbus-7 ERB Zonal Means Tape. There are three types of files on a FGGE/ERBZ tape: a tape header file, and data files. Physical characteristics, gross format, and file specifications are given. A sample tape check/document printout (shipping letter) is included.

  8. Forearm Skin Blood Flow After Kinesiology Taping in Healthy Soccer Players: An Exploratory Investigation

    PubMed Central

    Woodward, Kirsty A.; Unnithan, Vish; Hopkins, Nicola D.

    2015-01-01

    Context Kinesiology tape (KT) has become popular among athletes for both injury prevention and rehabilitation due to its reported therapeutic effects, including facilitation of lymphatic flow and enhanced peripheral blood flow. However, evidence to support such claims is insufficient. Objective To determine whether KT improves skin blood flow (SkBF) responses in young, elite soccer players. Design Randomized crossover study. Setting Research laboratory. Patients or Other Participants Thirteen healthy, elite, adolescent male soccer players (age = 14.7 ± 0.6 years). Intervention(s) Participants completed 2 experimental trials; during trial 1, the volar aspect of the dominant forearm was taped. Forearm SkBF was measured within the taped area and 3 cm lateral to the taped area. During trial 2, no tape was applied to either site. Both trials were performed within 7 days. Main Outcome Measure(s) Baseline and maximal thermally (42°C) stimulated SkBF responses were assessed using laser Doppler flowmetry. Continuously measured SkBF and derived mean arterial pressure obtained at 5-minute intervals were used to calculate cutaneous vascular conductance (CVC), the primary outcome measure. Results No differences were observed for baseline SkBF or CVC between trials or measurement sites. After local heating, no differences were evident for SkBF or CVC between trials or measurement sites. Conclusions Our findings suggest that, in healthy, trained adolescent males, KT was not associated with increased forearm SkBF. PMID:26445024

  9. FGGE/ERBM tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The Nimbus-7 FGGE/ERBM tape contains 27 ERB parameters which are extracted and reformatted from the Nimbus-7 ERB-MATRIX tape. There are four types of files on a FGGE/ERBM tape: a test file; tape-header file which describes the data set characteristics and the contents of the tape; a grid-descriptor file which contains the information of the ERB scanning channel target number and their associated latitude limits and longitude intervals; and one or more data files. A single end-of-file (EOF) tape mark is written after each file, and two EOF marks are written after the last data file on the tape.

  10. Delayed latency of peroneal reflex to sudden inversion with ankle taping or bracing.

    PubMed

    Shima, N; Maeda, A; Hirohashi, K

    2005-01-01

    The purpose of the present study was to examine the effects of ankle taping and bracing based on the peroneal reflex in the hypermobile and normal ankle joints with and without history of ankle injury. Thirty-six ankle joints of 18 collegiate American football athletes with and without previous history of injury were studied. The angle of talar tilt (TT) was measured by stress radiograph for classifying normal (TT5 degrees ) ankles. They were tested with taping, bracing, and without any supports as a control. The latency of peroneus longus muscle was measured by a sudden inversion of 25 degrees using surface EMG signals. The results of the present study show no significant three-way Group (hypermobile or normal ankles) by History (previously injured or uninjured ankles) by Condition (control, taping, or bracing) interaction, while Condition main effect was significant (p<0.05). There were significant differences between control (80.8 ms) and taping (83.8 ms, p<0.01), between control and bracing (83.0 ms, p<0.05), but not between taping and bracing (p>0.05). In conclusion, ankle taping and bracing delayed the peroneal reflex latency not only for hypermobile ankles and/or injured ankle joints but also for intact ankle joints.

  11. Study of probe-sample distance for biomedical spectra measurement.

    PubMed

    Wang, Bowen; Fan, Shuzhen; Li, Lei; Wang, Cong

    2011-11-02

    Fiber-based optical spectroscopy has been widely used for biomedical applications. However, the effect of probe-sample distance on the collection efficiency has not been well investigated. In this paper, we presented a theoretical model to maximize the illumination and collection efficiency in designing fiber optic probes for biomedical spectra measurement. This model was in general applicable to probes with single or multiple fibers at an arbitrary incident angle. In order to demonstrate the theory, a fluorescence spectrometer was used to measure the fluorescence of human finger skin at various probe-sample distances. The fluorescence spectrum and the total fluorescence intensity were recorded. The theoretical results show that for single fiber probes, contact measurement always provides the best results. While for multi-fiber probes, there is an optimal probe distance. When a 400- μm excitation fiber is used to deliver the light to the skin and another six 400- μm fibers surrounding the excitation fiber are used to collect the fluorescence signal, the experimental results show that human finger skin has very strong fluorescence between 475 nm and 700 nm under 450 nm excitation. The fluorescence intensity is heavily dependent on the probe-sample distance and there is an optimal probe distance. We investigated a number of probe-sample configurations and found that contact measurement could be the primary choice for single-fiber probes, but was very inefficient for multi-fiber probes. There was an optimal probe-sample distance for multi-fiber probes. By carefully choosing the probe-sample distance, the collection efficiency could be enhanced by 5-10 times. Our experiments demonstrated that the experimental results of the probe-sample distance dependence of collection efficiency in multi-fiber probes were in general agreement with our theory.

  12. Forensic utility of the carbon isotope ratio of PVC tape backings

    NASA Astrophysics Data System (ADS)

    Stern, L. A.; Thompson, A. H.; Mehltretter, A. H.; McLaskey, V.; Parish, A.; Aranda, R.

    2008-12-01

    Forensic interest in adhesive tapes with PVC-backings (polyvinyl chloride, electrical tapes) derives from their use in construction of improvised explosive devices, drug packaging and in a variety of other illicit activities. Due to the range of physical characteristics and chemical compositions of such tapes, traditional microscopic and chemical analysis of the tape backings and adhesives offer a high degree of discrimination between tapes from different manufacturers and products. To evaluate whether carbon isotope ratios may be able to increase discrimination of electrical tapes, particularly with regards to different tapes of the same product, we assessed the PVC-backings of 87 rolls of black electrical tape for their δ13C values. The adhesive on these tapes was physically removed with hexane, and plasticizers within the PVC tape backings were removed by three-20 minute extractions with chloroform. The δ13C values of the PVC tape backings ranged between -23.8 and -41.5 (‰ V-PDB). The carbon isotopic variation within a product (identical brand and product identification) is significant, based on five products with at least 3 rolls (ranges of 7.4‰ (n=3), 10.0‰ (n=6), 4.2‰ (n=16), 3.8‰ (n=6), and 11.5‰ (n=8), respectively). There was no measurable carbon isotope variation in regards to the following: a) along the length of a roll (4 samples from 1 roll); b) between the center and edge of a strip of tape (1 pair); c) between rolls assumed to be from the same lot of tape (2 pairs); d) between different rolls from the same batch of tape (same product purchased at the same time and place; 5 pairs); and e) between samples of a tape at room temperature, heated to 50° C and 80° C for 1 week. For each sample within the population of 87 tapes, carbon isotopes alone exclude 80 to 100% of the tapes as a potential match, with an average exclusion power of 92.5%, using a window of ± 0.4‰. Carbon isotope variations originate from variations in starting

  13. Caught (Unfortunately) on Tape

    ERIC Educational Resources Information Center

    Young, Jeffrey R.

    2009-01-01

    Recording class sessions so students can view them online is becoming routine on many campuses. But all that taping can lead to "uh-oh moments," such as when a professor's joke about the college dean ends up on YouTube, or a private comment to a student after class is inadvertently broadcast. Some lecture bloopers caught on tape are…

  14. Radio Astronomers Set New Standard for Accurate Cosmic Distance Measurement

    NASA Astrophysics Data System (ADS)

    1999-06-01

    A team of radio astronomers has used the National Science Foundation's Very Long Baseline Array (VLBA) to make the most accurate measurement ever made of the distance to a faraway galaxy. Their direct measurement calls into question the precision of distance determinations made by other techniques, including those announced last week by a team using the Hubble Space Telescope. The radio astronomers measured a distance of 23.5 million light-years to a galaxy called NGC 4258 in Ursa Major. "Ours is a direct measurement, using geometry, and is independent of all other methods of determining cosmic distances," said Jim Herrnstein, of the National Radio Astronomy Observatory (NRAO) in Socorro, NM. The team says their measurement is accurate to within less than a million light-years, or four percent. The galaxy is also known as Messier 106 and is visible with amateur telescopes. Herrnstein, along with James Moran and Lincoln Greenhill of the Harvard- Smithsonian Center for Astrophysics; Phillip Diamond, of the Merlin radio telescope facility at Jodrell Bank and the University of Manchester in England; Makato Inoue and Naomasa Nakai of Japan's Nobeyama Radio Observatory; Mikato Miyoshi of Japan's National Astronomical Observatory; Christian Henkel of Germany's Max Planck Institute for Radio Astronomy; and Adam Riess of the University of California at Berkeley, announced their findings at the American Astronomical Society's meeting in Chicago. "This is an incredible achievement to measure the distance to another galaxy with this precision," said Miller Goss, NRAO's Director of VLA/VLBA Operations. "This is the first time such a great distance has been measured this accurately. It took painstaking work on the part of the observing team, and it took a radio telescope the size of the Earth -- the VLBA -- to make it possible," Goss said. "Astronomers have sought to determine the Hubble Constant, the rate of expansion of the universe, for decades. This will in turn lead to an

  15. Notes on modified trace distance measure of coherence

    NASA Astrophysics Data System (ADS)

    Chen, Bin; Fei, Shao-Ming

    2018-05-01

    We investigate the modified trace distance measure of coherence recently introduced in Yu et al. [Phys. Rev. A 94, 060302(R), 2016]. We show that for any single-qubit state, the modified trace norm of coherence is equal to the l1-norm of coherence. For any d-dimensional quantum system, an analytical formula of this measure for a class of maximally coherent mixed states is provided. The trade-off relation between the coherence quantified by the new measure and the mixedness quantified by the trace norm is also discussed. Furthermore, we explore the relation between the modified trace distance measure of coherence and other measures such as the l1-norm of coherence and the geometric measure of coherence.

  16. 14 CFR 420.70 - Separation distance measurement requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Separation distance measurement requirements. 420.70 Section 420.70 Aeronautics and Space COMMERCIAL SPACE TRANSPORTATION, FEDERAL AVIATION... energetic liquids or net explosive weight that requires the greater distance. [Docket No. FAA-2011-0105, 77...

  17. 14 CFR 420.70 - Separation distance measurement requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Separation distance measurement requirements. 420.70 Section 420.70 Aeronautics and Space COMMERCIAL SPACE TRANSPORTATION, FEDERAL AVIATION... energetic liquids or net explosive weight that requires the greater distance. [Docket No. FAA-2011-0105, 77...

  18. Immediate Effects of Ankle Balance Taping with Kinesiology Tape for Amateur Soccer Players with Lateral Ankle Sprain: A Randomized Cross-Over Design

    PubMed Central

    Kim, Myoung Kwon; Shin, Young Jun

    2017-01-01

    Background The objective of this study was to investigate the immediate effect on gait function when ankle balance taping is applied to amateur soccer players with lateral ankle sprain. Material/Methods A cross-over randomized design was used. Twenty-two soccer players with an ankle sprain underwent 3 interventions in a random order. Subjects were randomly assigned to ankle balance taping, placebo taping, and no taping groups. The assessment was performed using the GAITRite portable walkway system, which records the location and timing of each footfall during ambulation. Results Significant differences were found in the velocity, step length, stride length, and H-H base support among the 3 different taping methods (p<0.05). The ankle balance taping group showed significantly greater velocity, step length, and stride length in comparison to the placebo and no taping group. The ankle balance taping group showed a statistically significant decrease (p<0.05) in the H-H base support compared to the placebo and no taping groups, and the placebo group showed significantly greater velocity in comparison to the no taping group (p<0.05). Conclusions We conclude that ankle balance taping that uses kinesiology tape instantly increased the walking ability of amateur soccer players with lateral ankle sprain. Therefore, ankle balance taping is a useful alternative to prevent and treat ankle sprain of soccer players. PMID:29158472

  19. Flux pinning in nanoparticle doped MgB 2/Cu tapes

    NASA Astrophysics Data System (ADS)

    Babić, E.; Kušević, I.; Husnjak, O.; Soltanian, S.; Wang, X. L.; Dou, S. X.

    2007-09-01

    The irreversibility fields Birr and critical current densities Jc of undoped and Si and SiC nanoparticle doped (5, 10 and 20 wt%) MgB2 tapes were measured in the temperature (T) range 2-38 K and in magnetic fields B ⩽ 16 T. Whereas Birr of undoped tapes varies smoothly with T, those of doped tapes show a change in slope around a crossover field Bcr which increases with nanoparticle content and also depends on their type. This indicates matching effect in vortex pinning, probably associated with Mg2Si nanoprecipitates formed during heat treatment. Indeed, Birr of doped tapes was enhanced in respect to that of undoped one with the highest enhancement for Birr ≈ Bcr, but the enhancement remained high ≈1.4 even for Birr ≫ Bcr (low temperatures). The variations of Jc and the pinning force density Fp = JcB with B and T support the above findings.

  20. High density tape/head interface study

    NASA Technical Reports Server (NTRS)

    Csengery, L. C.

    1983-01-01

    The high energy (H sub c approximately or = to 650 oersteds) tapes and high track density (84 tracks per inch) heads investigated had, as its goal, the definition of optimum combinations of head and tape, including the control required of their interfacial dynamics that would enable the manufacture of high rate (150 Mbps) digital tape recorders for unattended space flight.

  1. Measuring Long-Distance Romantic Relationships: A Validity Study

    ERIC Educational Resources Information Center

    Pistole, M. Carole; Roberts, Amber

    2011-01-01

    This study investigated aspects of construct validity for the scores of a new long-distance romantic relationship measure. A single-factor structure of the long-distance romantic relationship index emerged, with convergent and discriminant evidence of external validity, high internal consistency reliability, and applied utility of the scores.…

  2. A compensation scheme for tape-speed variation in cassette recorders.

    PubMed

    Wodicka, G R; Aguirre, A; Burns, S K; Shannon, D C

    1988-06-01

    A scheme to reduce the data corruption caused by tape-speed variation in cassette recorders used for monitoring infant apnea was developed. Low-frequency timing information is recorded on the tape, under the constraints of the frequency response of the recorder, simultaneously with the other signals. This information is extracted during playback and multiplied to a frequency suitable for data sampling, using an electronic, phase-locked loop. Analog-to-digital conversion of the data is performed at a rate proportional to the tape speed, resulting in compensation for speed variation. No direct modification of the speed-control mechanism of the recorder is required. The scheme was evaluated by comparing interval measurements of recorded timing information with and without compensation. Compensation reduced the error of the measurement by nearly an order of magnitude, which was consistent with theoretical predictions. This allows analysis of clinical value to be performed on signals recorded by systems that lack sophisticated speed-control mechanisms.

  3. Optoelectronic System Measures Distances to Multiple Targets

    NASA Technical Reports Server (NTRS)

    Liebe, Carl Christian; Abramovici, Alexander; Bartman, Randall; Chapsky, Jacob; Schmalz, John; Coste, Keith; Litty, Edward; Lam, Raymond; Jerebets, Sergei

    2007-01-01

    An optoelectronic metrology apparatus now at the laboratory-prototype stage of development is intended to repeatedly determine distances of as much as several hundred meters, at submillimeter accuracy, to multiple targets in rapid succession. The underlying concept of optoelectronic apparatuses that can measure distances to targets is not new; such apparatuses are commonly used in general surveying and machining. However, until now such apparatuses have been, variously, constrained to (1) a single target or (2) multiple targets with a low update rate and a requirement for some a priori knowledge of target geometry. When fully developed, the present apparatus would enable measurement of distances to more than 50 targets at an update rate greater than 10 Hz, without a requirement for a priori knowledge of target geometry. The apparatus (see figure) includes a laser ranging unit (LRU) that includes an electronic camera (photo receiver), the field of view of which contains all relevant targets. Each target, mounted at a fiducial position on an object of interest, consists of a small lens at the output end of an optical fiber that extends from the object of interest back to the LRU. For each target and its optical fiber, there is a dedicated laser that is used to illuminate the target via the optical fiber. The targets are illuminated, one at a time, with laser light that is modulated at a frequency of 10.01 MHz. The modulated laser light is emitted by the target, from where it returns to the camera (photodetector), where it is detected. Both the outgoing and incoming 10.01-MHz laser signals are mixed with a 10-MHz local-oscillator to obtain beat notes at 10 kHz, and the difference between the phases of the beat notes is measured by a phase meter. This phase difference serves as a measure of the total length of the path traveled by light going out through the optical fiber and returning to the camera (photodetector) through free space. Because the portion of the path

  4. Design and implementation of scalable tape archiver

    NASA Technical Reports Server (NTRS)

    Nemoto, Toshihiro; Kitsuregawa, Masaru; Takagi, Mikio

    1996-01-01

    In order to reduce costs, computer manufacturers try to use commodity parts as much as possible. Mainframes using proprietary processors are being replaced by high performance RISC microprocessor-based workstations, which are further being replaced by the commodity microprocessor used in personal computers. Highly reliable disks for mainframes are also being replaced by disk arrays, which are complexes of disk drives. In this paper we try to clarify the feasibility of a large scale tertiary storage system composed of 8-mm tape archivers utilizing robotics. In the near future, the 8-mm tape archiver will be widely used and become a commodity part, since recent rapid growth of multimedia applications requires much larger storage than disk drives can provide. We designed a scalable tape archiver which connects as many 8-mm tape archivers (element archivers) as possible. In the scalable archiver, robotics can exchange a cassette tape between two adjacent element archivers mechanically. Thus, we can build a large scalable archiver inexpensively. In addition, a sophisticated migration mechanism distributes frequently accessed tapes (hot tapes) evenly among all of the element archivers, which improves the throughput considerably. Even with the failures of some tape drives, the system dynamically redistributes hot tapes to the other element archivers which have live tape drives. Several kinds of specially tailored huge archivers are on the market, however, the 8-mm tape scalable archiver could replace them. To maintain high performance in spite of high access locality when a large number of archivers are attached to the scalable archiver, it is necessary to scatter frequently accessed cassettes among the element archivers and to use the tape drives efficiently. For this purpose, we introduce two cassette migration algorithms, foreground migration and background migration. Background migration transfers cassettes between element archivers to redistribute frequently accessed

  5. Structural modeling of HTS tapes and cables

    NASA Astrophysics Data System (ADS)

    Allen, N. C.; Chiesa, L.; Takayasu, M.

    2016-12-01

    Structural finite element analysis (FEA) has been used as an insightful tool to investigate the electromechanical behavior of HTS REBCO tapes and twisted stacked-tape cables under tension, torsion, bending and combined loads. A novel technique was developed for modeling the layered composite structure of the 2G tapes with structural solid-shell elements in ANSYS®. The FEA models produced detailed strain information for the REBCO superconducting layer which was then paired with an analytical model to predict the critical current performance of the 2G HTS tapes under various loads. Two commercially available HTS tapes (SuperPower and SuNAM) under tension, torsion and combined tension-torsion were first analyzed with FEA and compared with available experimental results at 77 K. A sharp critical current degradation was experienced at the yield strength of the tapes under tension and below a 100 mm twist-pitch under torsion. Combined tension-torsion loads had a more gradual degradation of critical current for twist-pitches of 115 mm or shorter but had a negligible difference compared to pure tension for longer twist-pitches. Using the structural solid-shell technique for modeling 2G tapes in ANSYS®, an FEA methodology for simulating full scale three-dimensional HTS stacked-tape cables under pure bending was created. A model of a Twisted-Stacked Tape Cable (TSTC), a configuration first proposed at MIT, was initially developed and then adapted to the slotted-core HTS Cable-In-Conduit Conductor produced by the ENEA laboratory in Italy. The numerical axial strain of the HTS REBCO tapes within the cables as calculated by FEA were found to agree with an analytical model for two cases: perfect-slip (frictionless) and no-slip (bonded). The ENEA CICC model was also compared with recent experimental critical current data at 77 K and was found to match best using a low friction coefficient of 0.02 indicating that the tapes within the cable freely slide with respect to each other

  6. Radiation effects measurements on spacecraft electrostatic discharge tapes, thermal blankets and thermooptical coatings

    NASA Technical Reports Server (NTRS)

    Bouquet, F. L.; Hribar, V. F.; Metzler, E. C.; Russell, D. A.

    1984-01-01

    Selective results are presented of laboratory radiation tests of metallic foil tapes, thermal blankets, and thermooptical coatings undertaken as part of the development and qualification of materials for the Galileo spacecraft. Of the two metallic foil tapes used for electrical continuity, the adhesive used on the aluminum embossed foil was superior to the copper embossed foil when exposed to simulated Jovian electrons. Proton-irradiation tests performed on a number of thermal blanket samples showed that black polyester on Kapton proved to be a lower weight loss (i.e., outgassing) material than Fluorglas. In addition, preliminary results concerning the response of thermooptical coatings to simulated Jovian electrons show that the ITO-coated polyester over a Kapton surface gave the lowest absorptance.

  7. Micro-Teaching Tapes in Anatomy and Physiology.

    ERIC Educational Resources Information Center

    Stencel, John E.

    1981-01-01

    Outlines the development and use of micro-teaching tapes as a means of supplemental instruction for college anatomy and physiology classes. Tapes include brief explanations of difficult concepts taken from lectures as students listen to cassette tapes and fill in blanks, or answer questions. (DS)

  8. Strategy for robot motion and path planning in robot taping

    NASA Astrophysics Data System (ADS)

    Yuan, Qilong; Chen, I.-Ming; Lembono, Teguh Santoso; Landén, Simon Nelson; Malmgren, Victor

    2016-06-01

    Covering objects with masking tapes is a common process for surface protection in processes like spray painting, plasma spraying, shot peening, etc. Manual taping is tedious and takes a lot of effort of the workers. The taping process is a special process which requires correct surface covering strategy and proper attachment of the masking tape for an efficient surface protection. We have introduced an automatic robot taping system consisting of a robot manipulator, a rotating platform, a 3D scanner and specially designed taping end-effectors. This paper mainly talks about the surface covering strategies for different classes of geometries. The methods and corresponding taping tools are introduced for taping of following classes of surfaces: Cylindrical/extended surfaces, freeform surfaces with no grooves, surfaces with grooves, and rotational symmetrical surfaces. A collision avoidance algorithm is introduced for the robot taping manipulation. With further improvements on segmenting surfaces of taping parts and tape cutting mechanisms, such taping solution with the taping tool and the taping methodology can be combined as a very useful and practical taping package to assist humans in this tedious and time costly work.

  9. Effects of Corrective Taping on Balance and Gait in Patients With Hallux Valgus.

    PubMed

    Gur, Gozde; Ozkal, Ozden; Dilek, Burcu; Aksoy, Songul; Bek, Nilgun; Yakut, Yavuz

    2017-05-01

    Taping is an effective temporary therapy for improving hallux valgus (HV) in adults. Although HV has been demonstrated to impair postural balance, there is a lack of information about how corrective taping affects balance and gait patterns in adults with HV deformity. Eighteen middle-aged female patients (average age, 53.5 years) with HV were included. Corrective tape was applied to correct HV angulation. A series of balance and gait stability tests were performed before applying tape and 1 hour after the tape was applied with a Balance Master computerized posturography device. The study involved the following tests: modified clinical test of sensory interaction and balance (mCTSIB), unilateral stance (US), limit of stability (LoS), step up/over (SUO), and walk across (WA) tests. No significant difference was found between the no-tape and taped condition in the static balance mCTSIB and US tests ( P > .05). The taping intervention resulted in significant improvement in the dynamic balance measures for the LoS test's backward reaction time and left maximum excursion ( P < .05), a significantly higher impact index bilaterally in the SUO assessment ( P < .05), and an increase in step width mean and variability in the WA test ( P < .05). Taping for correcting HV angulation had negative acute effects on dynamic balance in the SUO and WA tests and positive effects in the LoS test. Corrective taping, although a form of conservative treatment for hallux valgus, has been insufficiently studied in terms of effects on balance. Our results show that taping, as an acute effect, may impair balance in middle-aged adults when walking or ascending and descending stairs.

  10. Chemical News Via Audio Tapes: Chemical Industry News

    ERIC Educational Resources Information Center

    Hanford, W. E.; And Others

    1972-01-01

    Tape coverage of internal R&D news now has a broader scope with improved features. A new tape series covering external news of broad interest has been initiated. The use of tape in a Continuing Education Program is discussed as the future plans for expanding the audio tape program. (1 reference) (Author)

  11. Tape-cast sensors and method of making

    DOEpatents

    Mukundan, Rangachary [Santa Fe, NM; Brosha, Eric L [Los Alamos, NM; Garzon, Fernando H [Santa Fe, NM

    2009-08-18

    A method of making electrochemical sensors in which an electrolyte material is cast into a tape. Prefabricated electrodes are then partially embedded between two wet layers of the electrolyte tape to form a green sensor, and the green sensor is then heated to sinter the electrolyte tape around the electrodes. The resulting sensors can be used in applications such as, but not limited to, combustion control, environmental monitoring, and explosive detection. A electrochemical sensor formed by the tape-casting method is also disclosed.

  12. Wire and Packing Tape Sandwiches

    ERIC Educational Resources Information Center

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  13. Archive Data Tape Library (ADTL)

    DOT National Transportation Integrated Search

    1983-01-01

    The purpose of this directory is to describe the procedures involved in using the ADTL as well as to identify and describe the data tapes contained in the ADTL. This directory provides a listing of the data tapes contained in the ADTL by mode of tran...

  14. Does Kinesiology tape counter exercise-related impairments of balance in the elderly?

    PubMed

    Hosp, Simona; Csapo, Robert; Heinrich, Dieter; Hasler, Michael; Nachbauer, Werner

    2018-05-01

    Maintaining balance is an essential requirement for the performance of daily tasks and sporting activities, particularly in older adults to prevent falls and associated injuries. Kinesiology tape has gained great popularity in sports and is frequently used as a tool for performance enhancement. However, there is little research investigating its influence on balance. The purpose of this study was to evaluate the effect of Kinesiology tape on dynamic balance, postural stability and knee proprioception after physical activity in healthy, older adults. Twelve physically active, healthy men aged 63-77 years performed the test on two separate days, with and without Kinesiology tape at the knee joint (prospective intervention with cross-over design). Dynamic balance during an obstacle-crossing task, postural stability in a single-leg stance test, and knee joint position sense as a measure of proprioception were examined before and after 30 min of downhill walking on a treadmill. The influences of taping condition and physical activity on all parameters were statistically tested using factorial ANOVAs. Factorial ANOVA revealed significant time × taping condition interaction effects on all performance parameters (p < 0.05), indicating that the exercise-related changes in dynamic balance, postural stability and knee proprioception differed between the two taping conditions. The deterioration of performance was always greater when no tape was used. This study demonstrated that physical exercise significantly deteriorated dynamic balance, postural stability and knee proprioception in older men. These effects can be attenuated through the usage of Kinesiology tape. By preventing exercise-related impairments of balance, Kinesiology tape might help reduce the risk of sports-associated falls and associated injuries. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Is Kinesio Taping to Generate Skin Convolutions Effective for Increasing Local Blood Circulation?

    PubMed Central

    Yang, Jae-Man; Lee, Jung-Hoon

    2018-01-01

    Background It is unclear whether traditional application of Kinesio taping, which produces wrinkles in the skin, is effective for improving blood circulation. This study investigated local skin temperature changes after the application of an elastic therapeutic tape using convolution and non-convolution taping methods (CTM/NCTM). Material/Methods Twenty-eight pain-free men underwent CTM and NCTM randomly applied to the right and left sides of the lower back. Using infrared thermography, skin temperature was measured before, immediately after application, 5 min later, 15 min later, and after the removal of the tape. Results Both CTM and NCTM showed a slight, but significant, decrease in skin temperature for up to 5 min. The skin temperature at 15 min and after the removal of the tape was not significantly different from the initial temperature for CTM and NCTM. There were also no significant differences in the skin temperatures between CTM and NCTM. Conclusions Our findings do not support a therapeutic effect of wrinkling the skin with elastic tape application as a technique to increase local blood flow. PMID:29332101

  16. Is Kinesio Taping to Generate Skin Convolutions Effective for Increasing Local Blood Circulation?

    PubMed

    Yang, Jae-Man; Lee, Jung-Hoon

    2018-01-14

    BACKGROUND It is unclear whether traditional application of Kinesio taping, which produces wrinkles in the skin, is effective for improving blood circulation. This study investigated local skin temperature changes after the application of an elastic therapeutic tape using convolution and non-convolution taping methods (CTM/NCTM). MATERIAL AND METHODS Twenty-eight pain-free men underwent CTM and NCTM randomly applied to the right and left sides of the lower back. Using infrared thermography, skin temperature was measured before, immediately after application, 5 min later, 15 min later, and after the removal of the tape. RESULTS Both CTM and NCTM showed a slight, but significant, decrease in skin temperature for up to 5 min. The skin temperature at 15 min and after the removal of the tape was not significantly different from the initial temperature for CTM and NCTM. There were also no significant differences in the skin temperatures between CTM and NCTM. CONCLUSIONS Our findings do not support a therapeutic effect of wrinkling the skin with elastic tape application as a technique to increase local blood flow.

  17. Using Ankle Bracing and Taping to Decrease Range of Motion and Velocity During Inversion Perturbation While Walking.

    PubMed

    Hall, Emily A; Simon, Janet E; Docherty, Carrie L

    2016-04-01

    Prophylactic ankle supports are commonly used. However, the effectiveness of external supports in preventing an inversion stress has been debated. To evaluate how ankle bracing and taping affect inversion range of motion, time to maximum inversion, inversion velocity, and perceived ankle stability compared with a control condition during a dynamic inversion perturbation while walking. Crossover study. Research laboratory. A total of 42 physically active participants (16 men, 26 women; age = 21.2 ± 3.3 years, height = 168.9 ± 8.9 cm, mass = 66.1 ± 11.4 kg) volunteered. Participants walked on a custom-built walkway that suddenly inverted their ankles to 30° in 3 conditions: brace, tape, and control (no external support). We used an ASO ankle brace for the brace condition and a closed basketweave technique for the tape condition. Three trials were completed for each condition. Main Outcome Measure(s) Maximum inversion (degrees), time to maximum inversion (milliseconds), and inversion velocity (degrees per second) were measured using an electrogoniometer, and perceived stability (centimeters) was measured using a visual analog scale. Maximum inversion decreased more in the brace condition (20.1°) than in the control (25.3°) or tape (22.3°) conditions (both P values = .001), and the tape condition restricted inversion more than the control condition (P = .001). Time to maximum inversion was greater in the brace condition (143.5 milliseconds) than in the control (123.7 milliseconds; P = .001) or tape (130.7 milliseconds; P = .009) conditions and greater in the tape than in the control condition (P = .02). Inversion velocity was slower in the brace condition (142.6°/s) than in the control (209.1°/s) or tape (174.3°/s) conditions (both P values = .001) and slower in the tape than in the control condition (P = .001). Both the brace and tape conditions provided more perceived stability (0.98 cm and 0.94 cm, respectively) than the control condition (2.38 cm; both P

  18. Reel-to-reel substrate tape polishing system

    DOEpatents

    Selvamanickam, Venkat; Gardner, Michael T.; Judd, Raymond D.; Weloth, Martin; Qiao, Yunfei

    2005-06-21

    Disclosed is a reel-to-reel single-pass mechanical polishing system (100) suitable for polishing long lengths of metal substrate tape (124) used in the manufacture of high-temperature superconductor (HTS) coated tape, including multiple instantiations of a polishing station (114) in combination with a subsequent rinsing station (116) arranged along the axis of the metal substrate tape (124) that is translating between a payout spool (110a) and a take-up spool (110b). The metal substrate tape obtains a surface smoothness that is suitable for the subsequent deposition of a buffer layer.

  19. Laser-plasma interactions from thin tapes for high-energy electron accelerators and seeding compact FELs

    NASA Astrophysics Data System (ADS)

    Shaw, Brian Henry

    This thesis comprises a detailed investigation of the physics of using a plasma mirror (PM) from a tape by reflecting ultrashort pulses from a laser-triggered surface plasma. The tapes used in the characterization of the PM are VHS and computer data storage tape. The tapes are 6.6 m (computer storage tape) and 15 m (VHS) thick. Each tape is 0.5 inches wide, and 10s of meters of tape are spooled using a tape drive; providing thousands of shots on a single reel of tape. The amount of reflected energy of the PM was studied for different input intensities. The fluence was varied by translating the focus of the laser upstream and downstream of the tape, which changed the spot size on the tape surface and hence changed the fluence. This study measured reflectances from both sides of the two tapes, and for input light of both s and p-polarizations. Lastly, an analytic model was developed to understand the reflectance as a function of fluence for each tape material and polarization. Another application that benefits from the advancements of LPA technology is an LPAbased FEL. By sending a high quality electron bunch through an undulator (a periodic structure of positive and negative magnetic poles), the electrons oscillate transversely to the propagation axis and produce radiation. The 1.5 m THUNDER undulator at the BELLA Center has been commissioned using electron beams of 400MeV beams with broad energy spread (35%). To produce a coherent LPA-based FEL, the beam quality would need to improve to sub-percent level energy spread. A seed source could be used to help induce bunching of the electron beam within the undulator. This thesis described the experimental investigation of the physics of using solid-based surface high-harmonic generation (SHHG) from a thin tape as a possible seed source for an FEL. A thin tape placed within centimeters of the undulator's entrance could act as a harmonic generating source, while simultaneously transmitting an electron beam. This removes

  20. THE EFFECT OF KINESIO® TAPE ON VERTICAL JUMP AND DYNAMIC POSTURAL CONTROL

    PubMed Central

    Baldridge, Carolann

    2013-01-01

    Introduction and Background: Ankle injuries are one of the most common injuries among physically active individuals. The role of prophylactic ankle taping and bracing has been studied extensively. Kinesio® Tape (KT) is a somewhat new type of taping technique gaining popularity as both treatment and performance enhancement tool. However, there is limited research on the effect of KT on functional performance. Purpose: The purpose of this study was to determine whether the application of Kinesio Tex® Tape had an effect on vertical jump and dynamic postural control in healthy young individuals. Methods: 52 healthy subjects free of ankle or lower extremity problems (28 males and 24 females; age: 22.12±2.08 years; height: 170.77±8.69 cm; weight: 69.90±12.03 kg) participated in the study. Subjects were randomly assigned to either the experimental group (KT with tension) or the control group (KT without tension). Vertical jump was measured using the VertiMetric device and dynamic postural control was assessed using the Star Excursion Balance Test (SEBT) under three conditions: (1) without taping; (2) immediately after taping; (3) 24 hours after taping with the taping remaining in situ. Results: Three-way repeated measure ANOVA was conducted in order to identify differences between the experimental and the control group during the three conditions. Overall, there were no differences between groups in vertical jump maximum height, vertical jump average height, or the SEBT scores for the three time periods (pre-test, post-test, 24hrs-post-test). However, the main effect of KT was moderated by a significant gender interaction, resulting in a statistically significant effect of KT for the SEBT scores in the posterior-medial direction, F(1.72, 82.57) = 4.50, p = 0.018 and the medial direction, F(1.75, 83.81) = 4.27, p = 0.021. Follow-up analyses indicated that female subjects in the KT group had increased SEBT scores between three time periods when compared to the placebo

  1. Measuring Distance of Fuzzy Numbers by Trapezoidal Fuzzy Numbers

    NASA Astrophysics Data System (ADS)

    Hajjari, Tayebeh

    2010-11-01

    Fuzzy numbers and more generally linguistic values are approximate assessments, given by experts and accepted by decision-makers when obtaining value that is more accurate is impossible or unnecessary. Distance between two fuzzy numbers plays an important role in linguistic decision-making. It is reasonable to define a fuzzy distance between fuzzy objects. To achieve this aim, the researcher presents a new distance measure for fuzzy numbers by means of improved centroid distance method. The metric properties are also studied. The advantage is the calculation of the proposed method is far simple than previous approaches.

  2. Neuromuscular taping versus sham therapy on muscular strength and motor performance in multiple sclerosis patients.

    PubMed

    Costantino, Cosimo; Pedrini, Martina Francesca; Licari, Oriana

    2016-01-01

    Purpose of this study is to evaluate differences in leg muscles strength and motor performance between neuromuscular taping (NT) and sham tape groups. Relapsing-remitting (RR) multiple sclerosis (MS) patients were recruited and randomly assigned to NT or sham tape groups. All patients underwent the treatment 5 times at 5-d intervals. They were submitted to a 6-minute walk test and isokinetic test (peak torque) at the beginning (T0), at the end (T1) and 2 months after the end of the treatment (T2). Forty MS patients (38 F; 2 M; mean age 45.5 ± 6.5 years) were assigned to NT group (n = 20) and to sham tape group (n = 20). Delta Peak Torque T1-T0 and T2-T0 between two groups were statistically significant in quadriceps (p = 0.007; 0.000) and hamstrings (p = 0.011; 0.007). The difference between the two groups according to 6-minute walk test was not statistically significant but in NT group it was noticed an increasing trend about the distance run. In this single-blind randomized controlled trial, NT seemed to increase strength in leg muscles, compared to a sham device, in RR MS patients. Further studies are needed to consider this therapy as a complement to classic physical therapy. Neuromuscular taping (NT) in multiple sclerosis: NT is well tolerated by multiple sclerosis patients and should be a complement to classic physical therapy. This technique normalizes muscular function, strengthens weakened muscles and assists the postural alignment.

  3. Ubiquitous Graphene Electronics on Scotch Tape

    PubMed Central

    Chung, Yoonyoung; Ho Kim, Hyun; Lee, Sangryun; Lee, Eunho; Won Kim, Seong; Ryu, Seunghwa; Cho, Kilwon

    2015-01-01

    We report a novel concept of graphene transistors on Scotch tape for use in ubiquitous electronic systems. Unlike common plastic substrates such as polyimide and polyethylene terephthalate, the Scotch tape substrate is easily attached onto various objects such as banknotes, curved surfaces, and human skin, which implies potential applications wherein electronics can be placed in any desired position. Furthermore, the soft Scotch tape serves as an attractive substrate for flexible/foldable electronics that can be significantly bent, or even crumpled. We found that the adhesive layer of the tape with a relatively low shear modulus relaxes the strain when subjected to bending. The capacitance of the gate dielectric made of oxidized aluminum oxide was 1.5 μF cm−2, so that a supply voltage of only 2.5 V was sufficient to operate the devices. As-fabricated graphene transistors on Scotch tape exhibited high electron mobility of 1326 (±155) cm2 V−1 s−1; the transistors still showed high mobility of 1254 (±478) cm2 V−1 s−1 even after they were crumpled. PMID:26220874

  4. Technique for recovery of voice data from heat damaged magnetic tape

    NASA Technical Reports Server (NTRS)

    Melugin, J. F.; Obrien, D. E., III (Inventor)

    1974-01-01

    A method for conditioning, and thus enabling retrieval of intelligence from, magnetic tapes after damage from heat has caused the tape to wrinkle and curl severely thereby reducing tape width to less than one-half its original size. The damaged tape is superposed on a first piece of splicing tape with the oxide side of the magnetic tape in contact with the adhesive side of the splicing tape and then carefully smoothed by a special tool. A second piece of splicing tape is placed on the backing side of the magnetic tape then the resulting tape stack is trimmed to the original width of the magnetic tape. After the first piece of splicing tape is carefully removed from the oxide side of the damaged magnetic tape, the resulting magnetic tape is then ready to be placed into a recorder for playback.

  5. A comparison of tape-tying versus a tube-holding device for securing endotracheal tubes in adults.

    PubMed

    Murdoch, E; Holdgate, A

    2007-10-01

    During the transfer of intubated patients, endotracheal tube security is paramount. This study aims to compare two methods of securing an endotracheal tube in adults: tying with a cloth tape versus the Thomas Endotracheal Tube Holder (Laerdal). A manikin-based study was performed using paramedics and critical care doctors (consultants and senior trainees) as participants. Each participant was asked to secure an endotracheal tube that had been placed within the trachea of a manikin a total of six times, the first three times using tied cloth tape and the last three times using a Thomas Endotracheal Tube Holder. Following each 'fixation' and after the participant had left the room, the security of the tube was tested by applying a fixed force laterally and to the right by dropping a 1.25 kg weight a distance of 50 cm. The amount of movement of the tube with respect to the teeth was measured and recorded in millimetres. Two-hundred-and-seventy tube fixations (135 tied vs. 135 tube holder) were performed by 45 participants. The degree of tube movement was significantly higher when the tube was secured with a tie compared with when the tube holder was used (median movement 22 mm vs. 4 mm, P < 0.0001). We have demonstrated that the tube holder device minimised tube movement in a manikin model when compared with conventional tape tying. The use of this device when transporting intubated patients may reduce the risk of tube displacement though further clinical studies are warranted.

  6. Design optimization of superconducting coils based on asymmetrical characteristics of REBCO tapes

    NASA Astrophysics Data System (ADS)

    Hong, Zhiyong; Li, Wenrong; Chen, Yanjun; Gömöry, Fedor; Frolek, Lubomír; Zhang, Min; Sheng, Jie

    2018-07-01

    Angle dependence Ic(B,θ) of superconducting tape is a crucial parameter to calculate the influence of magnetic field during the design of superconducting applications,. This paper focuses on the asymmetrical characteristics found in REBCO tapes and further applications based on this phenomenon. This paper starts with angle dependence measurements of different HTS tapes, asymmetrical characteristics are found in some of the testing samples. On basis of this property, optimization of superconducting coils in superconducting motor, transformer and insert magnet is discussed by simulation. Simplified experiments which represent the structure of insert magnet were carried out to prove the validity of numerical studies. Conclusions obtained in this paper show that the asymmetrical property of superconducting tape is quite important in design of superconducting applications, and optimized winding technique based on this property can be used to improve the performance of superconducting devices.

  7. Specification for wide channel bandwidth one-inch video tape

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1988-01-01

    Standards and controls are established for the procurement of wide channel bandwidth one inch video magnetic recording tapes for Very Long Base Interferometer (VLBI) system applications. The Magnetic Tape Certification Facility (MTCF) currently maintains three specifications for the Quality Products List (QPL) and acceptance testing of magnetic tapes. NASA-TM-79724 is used for the QPL and acceptance testing of new analog tapes; NASA-TM-80599 is used for QPL and acceptance testing of new digital tapes; and NASA-TM-100702 is used for the QPL and acceptance testing of new IBM/IBM compatible 3480 magnetic tape cartridges. This specification will be used for the QPL and acceptance testing of new wide channel bandwidth one inch video magnetic recording tapes. The one inch video tapes used by the Jet Propulsion Lab., the Deep Space Network and the Haystack Observatory will be covered by this specification. These NASA stations will use the video tapes for their VLBI system applications. The VLBI system is used for the tracking of quasars and the support of interplanetary exploration.

  8. User's guide and tape specification for ERB 7 DELMAT

    NASA Technical Reports Server (NTRS)

    Ardanuy, P.; Penn, L.

    1985-01-01

    Guidance is provided to the DELMAT user in the areas of purpose, use and limitations of DELMAT tapes and software. The DELMAT tape specifications is also provided. The ERB-7, ERB MAT and tape characteristics applicable to the DELMAT tapes are also summarized.

  9. Magnetic Tape Recording

    NASA Technical Reports Server (NTRS)

    Athey, Skipwith W.

    1966-01-01

    NASA's contribution to tape recorder technology may appear to lie in such glamorous devices as the tape recorders of the Tiros and Nimbus satellites which receive signals carrying weather information during an orbit around the earth and then transmit those signals back to the ground when the satellite is in view of ground stations. These quite important recording devices are, however, only useful as members of a complex hierarchy of devices all of which participate in the ultimate process of obtaining information from NASA's efforts. Their existence and utility is based on the existence of many more prosaic recording devices which have been involved in the development of such spectacular units.

  10. An improved magnetic tape recorder

    NASA Technical Reports Server (NTRS)

    Uber, P. W.

    1968-01-01

    Magnetic tape recorder employs a single capstan for simultaneously driving the supply and take-up reels in such a manner that the tape passing between the reels is kept under a predetermined constant tension. This recorder operates with little power and is sufficiently rugged to withstand the severe stresses encountered in high-altitude balloon flight tests.

  11. Recoil distance lifetime measurements in 122,124Xe

    NASA Astrophysics Data System (ADS)

    Govil, I. M.; Kumar, A.; Iyer, H.; Li, H.; Garg, U.; Ghugre, S. S.; Johnson, T.; Kaczarowski, R.; Kharraja, B.; Naguleswaran, S.; Walpe, J. C.

    1998-02-01

    Lifetimes of the lower-excited states in 122,124Xe are measured using the recoil-distance Doppler-shift technique. The reactions 110Pd(16O,4n)122Xe and 110Pd(18O,4n)124Xe at a beam energy of 66 MeV were used for this experiment. The lifetimes of the 2+, 4+, 6+, and 8+ states of the ground state band were extracted using the computer code LIFETIME including the corrections due to the side feeding and the nuclear deorientation effects. The lifetime of the 2+ state in 122Xe agrees with the recoil distance method (RDM) measurements but for the 124Xe it does not agree with the RDM measurements but agrees with the Coulomb-excitation experiment. The measured B(E2) values for both the nuclei are compared with the standard algebraic and the multishell models.

  12. A study of tape adhesive strength on endotracheal tubes.

    PubMed

    Fenje, N; Steward, D J

    1988-03-01

    A method of assessing the adhesive bond of tapes used to secure endotracheal (ET) tubes is described. Five kinds of tape and six different ET tubes including two silicone rubber, wire-reinforced tubes were tested. There are significant differences in the adhesive strength of different tapes, and in the adhesive bond formed by different ET tube materials. On the Portex clear ET tube, silk tape adhered best (p less than 0.001), followed by waterproof, cloth, dermiclear, and micropore tapes. Adhesive bonding by silk tape was significantly greater (p less than 0.001) for the three clear ET tubes (Portex clear, NCC clear, and Portex ivory) than for the Portex blue and the silicone rubber, wire-reinforced ET tubes. All tapes showed very poor or negligible adhesion to the Sheridan and Portex reinforced ET tubes. Adhesion to these tubes was greatly improved by wrapping them tightly with an "op site" dressing prior to applying tape.

  13. TVT ABBREVO: cadaveric study of tape position in foramen obturatum and adductor region.

    PubMed

    Hubka, Petr; Nanka, Ondrej; Masata, Jaromir; Martan, Alois; Svabik, Kamil

    2016-07-01

    The aim of the study was to describe fixation of the TVT ABBREVO and establish whether the tape penetrates through obturator muscles and membrane (obturator complex) into the adductor region and, if so, how far it penetrates. Eight formalin-embalmed female cadavers were used to simulate TVT ABBREVO surgery (totalling 16 insertions). Following tape insertion, dissection was performed and ends of the tape were identified. In cases of penetration, the length of tape penetrating into the adductor region was measured. Of the 16 cases, the tape ended in the obturator membrane in eight, in the internal obturator muscle in one, and penetrated through the obturator membrane into the external obturator muscle in five, where it remained. In two cases, it penetrated through the obturator internus muscle, obturator membrane and obturator externus muscle into the group of thigh adductors; one penetration was by 3 mm and the second by 10 mm. No contact with the obturator nerve or its branches was noted in any case. No TVT contact with the obturator nerve was noted; tape penetrated into the adductor region in two of the 16 cases.

  14. Nanoscale Interparticle Distance within Dimers in Solution Measured by Light Scattering

    PubMed Central

    2017-01-01

    We demonstrate a novel approach to quantify the interparticle distance in colloidal dimers using Mie scattering. The interparticle distance is varied in a controlled way by changing the ionic strength of the solution and the magnetic attraction between the particles. The measured scaling behavior is interpreted using an energy–distance model that includes the repulsive electrostatic and attractive magnetic interactions. The center-to-center distances of particles with a 525 nm radius can be determined with a root-mean-square accuracy of 12 nm. The data show that the center-to-center distance is larger by 83 nm compared to perfect spheres. The underlying distance offset can be attributed to repulsion by charged protrusions caused by particle surface roughness. The measurement method accurately quantifies interparticle distances that can be used to study cluster formation and colloid aggregation in complex systems, e.g., in biosensing applications. PMID:29183122

  15. Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grin, A.; Lstiburek, J.

    This guide provides information and recommendations to the following groups: insulation contractors; general contractors; builders; home remodelers; mechanical contractors; and homeowners, as a guide to the work that needs to be done. The order of work completed during home construction and retrofit improvements is important. Health and safety issues must be addressed first and are more important than durability issues. And durability issues are more important than saving energy. Not all techniques can apply to all houses. Special conditions will require special action. Some builders or homeowners will wish to do more than the important but basic retrofit strategies outlinedmore » by this guide. The following are best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant items were discussed with the group which are required to make taped insulating sheathing a simple, long term, and durable drainage plane: 1. Horizontal joints should be limited or eliminated wherever possible; 2. Where a horizontal joint exists use superior materials; 3. Frequent installation inspection and regular trade training are required to maintain proper installation. Section 5 of this measure guideline contains the detailed construction procedure for the three recommended methods to effectively seal the joints in exterior insulating sheathing to create a simple, long term, and durable drainage plane.« less

  16. Tape SCSI monitoring and encryption at CERN

    NASA Astrophysics Data System (ADS)

    Laskaridis, Stefanos; Bahyl, V.; Cano, E.; Leduc, J.; Murray, S.; Cancio, G.; Kruse, D.

    2017-10-01

    CERN currently manages the largest data archive in the HEP domain; over 180PB of custodial data is archived across 7 enterprise tape libraries containing more than 25,000 tapes and using over 100 tape drives. Archival storage at this scale requires a leading edge monitoring infrastructure that acquires live and lifelong metrics from the hardware in order to assess and proactively identify potential drive and media level issues. In addition, protecting the privacy of sensitive archival data is becoming increasingly important and with it the need for a scalable, compute-efficient and cost-effective solution for data encryption. In this paper, we first describe the implementation of acquiring tape medium and drive related metrics reported by the SCSI interface and its integration with our monitoring system. We then address the incorporation of tape drive real-time encryption with dedicated drive hardware into the CASTOR [1] hierarchical mass storage system.

  17. The effectiveness of Kinesio Taping on pain and disability in cervical myofascial pain syndrome.

    PubMed

    Ay, Saime; Konak, Hatice Ecem; Evcik, Deniz; Kibar, Sibel

    The aim of this study was to investigate the effectiveness of Kinesio Taping and sham Kinesio Taping on pain, pressure pain threshold, cervical range of motion, and disability in cervical myofascial pain syndrome patients (MPS). This study was designed as a randomized, double-blind placebo controlled study. Sixty-one patients with MPS were randomly assigned into two groups. Group 1 (n=31) was treated with Kinesio Taping and group 2 (n=30) was treated sham taping five times by intervals of 3 days for 15 days. Additionally, all patients were given neck exercise program. Patients were evaluated according to pain, pressure pain threshold, cervical range of motion and disability. Pain was assessed by using Visual Analog Scale, pressure pain threshold was measured by using an algometer, and active cervical range of motion was measured by using goniometry. Disability was assessed with the neck pain disability index disability. Measurements were taken before and after the treatment. At the end of the therapy, there were statistically significant improvements on pain, pressure pain threshold, cervical range of motion, and disability (p<0.05) in both groups. Also there was a statistical difference between the groups regarding pain, pressure pain threshold, cervical flexion-extension (p<0.05); except cervical rotation, cervical lateral flexion and disability (p>0.05). This study shows that Kinesio Taping leads to improvements on pain, pressure pain threshold and cervical range of motion, but not disability in short time. Therefore, Kinesio Taping can be used as an alternative therapy method in the treatment of patients with MPS. Copyright © 2016 Elsevier Editora Ltda. All rights reserved.

  18. Educational Uses of Cartridge Tapes. Dissemination Document No. 11.

    ERIC Educational Resources Information Center

    Levine, S. Joseph

    Tape cartridges for use by special education teachers are analyzed according to design, effective use, and availability. Basic operating principles of cassette and continuous loop tape cartridges are described and illustrated. Advantages of tape cartridges are indicated, such as the following: the position is saved on tape during student timeouts,…

  19. The effectiveness of tape playbacks in estimating Black Rail densities

    USGS Publications Warehouse

    Legare, M.; Eddleman, W.R.; Buckley, P.A.; Kelly, C.

    1999-01-01

    Tape playback is often the only efficient technique to survey for secretive birds. We measured the vocal responses and movements of radio-tagged black rails (Laterallus jamaicensis; 26 M, 17 F) to playback of vocalizations at 2 sites in Florida during the breeding seasons of 1992-95. We used coefficients from logistic regression equations to model probability of a response conditional to the birds' sex. nesting status, distance to playback source, and time of survey. With a probability of 0.811, nonnesting male black rails were ))lost likely to respond to playback, while nesting females were the least likely to respond (probability = 0.189). We used linear regression to determine daily, monthly and annual variation in response from weekly playback surveys along a fixed route during the breeding seasons of 1993-95. Significant sources of variation in the regression model were month (F3.48 = 3.89, P = 0.014), year (F2.48 = 9.37, P < 0.001), temperature (F1.48 = 5.44, P = 0.024), and month X year (F5.48 = 2.69, P = 0.031). The model was highly significant (P < 0.001) and explained 54% of the variation of mean response per survey period (r2 = 0.54). We combined response probability data from radiotagged black rails with playback survey route data to provide a density estimate of 0.25 birds/ha for the St. Johns National Wildlife Refuge. The relation between the number of black rails heard during playback surveys to the actual number present was influenced by a number of variables. We recommend caution when making density estimates from tape playback surveys

  20. Effects of functional taping compared with sham taping and minimal intervention on pain intensity and static postural control for patients with non-specific chronic low back pain: a randomised clinical trial protocol.

    PubMed

    Jassi, F J; Del Antônio, T; Moraes, R; George, S Z; Chaves, T C

    2017-06-01

    To investigate the immediate and 1-month effects of functional taping to lumbar spine for pain intensity and postural control in patients with chronic non-specific low back pain. Randomised clinical trial. One hundred and twenty participants aged 18 to 50 years. Participants will be allocated at random to receive one of three interventions: functional star-shape taping for 7 days, sham functional taping for 7 days or minimal intervention, one session. The primary outcomes will be pain intensity and postural control. Four measurements of static posturography will be conducted: pre-intervention, immediately after application of the tape, 7 days post-intervention (after removal of the tape) and 1-month follow-up. The secondary outcomes will be low-back-pain-related disability, global perceived effect of treatment and fear avoidance beliefs. Primary and secondary outcomes will be assessed on three occasions: pre-intervention, 7 days post-intervention and at 1-month follow-up. All statistical analyses will be conducted following intention-to-treat principles, and the treatment effects will be calculated using linear mixed models. The results of this study will determine the effects of functional taping on pain intensity and postural control compared with sham taping and minimal intervention. NCT02546466. Copyright © 2016 Chartered Society of Physiotherapy. All rights reserved.

  1. Methods and systems for fabricating high quality superconducting tapes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Majkic, Goran; Selvamanickam, Venkat

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  2. The Ergogenic Effect of Elastic Therapeutic Tape on Stride and Step Length in Fatigued Runners

    PubMed Central

    Ward, John; Sorrels, Kenneth; Coats, Jesse; Pourmoghaddam, Amir; Moskop, JoAnn; Ueckert, Kate; Glass, Amanda

    2014-01-01

    Objective The purpose of this study was to determine if elastic therapeutic tape placed on anterior lower limbs would affect stride and step length in fatigued runners’ gait. Methods Forty-two healthy participants were equally divided into a kinesiology tape group (Rocktape) and a no-tape control group. Participants in both groups underwent a baseline running gait test at 6 mph without tape. After this, participants engaged in an exhaustive lower body fatigue protocol until they reached maximal volitional exhaustion. Participants were then randomized to 1 of 2 interventions: (1) Experimental group, which had kinesiology tape placed under tension on the anterior aspect of their lower limbs bilaterally from the upper thigh to just below the patella, or (2) Control group, which did not receive taping. All participants then engaged in a similar 6-mph running gait postanalysis. Participant’s gait was analyzed for 90 seconds during each test iteration. Researchers used a 2-way repeated-measures analysis of variance considering fatigue (prefatigue, postfatigue) and group (tape, no-tape) as subject factors. Results After the fatigue protocol, the no-tape group demonstrated a significant decrease in step length of 14.2 mm (P = .041) and stride length of 29.4 mm (P = .043). The kinesiology tape group did not demonstrate a significant decline in these gait parameters. Conclusions In this preliminary study, placing elastic therapeutic tape over the anterior lower limbs demonstrated short-term preservation of runner step length and stride length in a fatigued state. PMID:25435835

  3. Ultrasound measurement of transcranial distance during head-down tilt

    NASA Technical Reports Server (NTRS)

    Torikoshi, S.; Wilson, M. H.; Ballard, R. E.; Watenpaugh, D. E.; Murthy, G.; Yost, W. T.; Cantrell, J. H.; Chang, D. S.; Hargens, A. R.

    1995-01-01

    Exposure to microgravity elevates blood pressure and flow in the head, which may increase intracranial volume (ICV) and intracranial pressure (ICP). Rhesus monkeys exposed to simulated microgravity in the form of 6 degree head-down tilt (HDT) experience elevated ICP. With humans, twenty-four hours of 6 degree HDT bed rest increases cerebral blood flow velocity relative to pre-HDT upright posture. Humans exposed to acute 6 degree HDT experiments increased ICP, measured with the tympanic membrane displacement (TMD) technique. Other studies suggest that increased ICP in humans and cats causes measurable cranial bone movement across the sagittal suture. Due to the slightly compliant nature of the cranium, elevation of the ICP will increase ICV and transcranial distance. Currently, several non-invasive approaches to monitor ICP are being investigated. Such techniques include TMD and modal analysis of the skull. TMD may not be reliable over a large range of ICP and neither method is capable of measuring the small changes in pressure. Ultrasound, however, may reliably measure small distance changes that accompany ICP fluctuations. The purpose of our study was to develop and evaluate an ultrasound technique to measure transcranial distance changes during HDT.

  4. Changes in Vertebral Column Height (VCH) at Different Distance Intervals During a 3-Mile Walk.

    PubMed

    Roush, J R; Kee, M; Toeppe, J

    2008-08-01

    The purpose of this study was to determine the changes in vertebral column height (VCH) of males and females, at every one-half mile, for a total walking distance of 3 miles. Twenty males and twenty females between the ages of 21 and 40 years walked 3 miles on a treadmill maintaining a walking speed that the subject rated between 12 and 14 on Borg's rate of perceived exertion scale. Blood pressure, heart rate, and VCH measurements were taken initially and at each half-mile interval throughout the three-mile walk. Vertebral column height (VCH) was measured from the spinous process of C7 to S2 using a standard tape measure. Significant differences existed in vertebral column height according to sex (F = 16.18; p < .05) and significant differences in vertebral column height at the different distances (F = 65.02: p < .0001). Significant changes occurred in the VCH between half-mile intervals only between 0.5 miles and 1.0 mile and between 1.0 mile and 1.5 miles during the walk. As found with a regression analysis, curvilinear relationship exists between the distance walked and VCH; with VCH decreasing throughout the distance of the walk. Vertebral column height decreased in a curvilinear relationship throughout the distance of walking 3 miles in both males and females.

  5. Changes in Vertebral Column Height (VCH) at Different Distance Intervals During a 3-Mile Walk

    PubMed Central

    Kee, M; Toeppe, J

    2008-01-01

    Background The purpose of this study was to determine the changes in vertebral column height (VCH) of males and females, at every one-half mile, for a total walking distance of 3 miles. Methods Twenty males and twenty females between the ages of 21 and 40 years walked 3 miles on a treadmill maintaining a walking speed that the subject rated between 12 and 14 on Borg's rate of perceived exertion scale. Blood pressure, heart rate, and VCH measurements were taken initially and at each half-mile interval throughout the three-mile walk. Vertebral column height (VCH) was measured from the spinous process of C7 to S2 using a standard tape measure. Results Significant differences existed in vertebral column height according to sex (F = 16.18; p < .05) and significant differences in vertebral column height at the different distances (F = 65.02: p < .0001). Significant changes occurred in the VCH between half-mile intervals only between 0.5 miles and 1.0 mile and between 1.0 mile and 1.5 miles during the walk. As found with a regression analysis, curvilinear relationship exists between the distance walked and VCH; with VCH decreasing throughout the distance of the walk. Conclusions Vertebral column height decreased in a curvilinear relationship throughout the distance of walking 3 miles in both males and females. PMID:21509126

  6. Study of the inhomogeneity of critical current under in-situ tensile stress for YBCO tape

    NASA Astrophysics Data System (ADS)

    Zhu, Y. P.; Chen, W.; Zhang, H. Y.; Liu, L. Y.; Pan, X. F.; Yang, X. S.; Zhao, Y.

    2018-07-01

    A Hall sensor system was used to measure the local critical current of YBCO tape with high spatial resolution under in-situ tensile stress. The hot spot generation and minimum quench energy of YBCO tape, which depended on the local critical current, was calculated through the thermoelectric coupling model. With the increase in tensile stress, the cracks which have different dimensions and critical current degradation arose more frequently and lowered the thermal stability of the YBCO tape.

  7. Short-Term Effects of Kinesio Taping and Cross Taping Application in the Treatment of Latent Upper Trapezius Trigger Points: A Prospective, Single-Blind, Randomized, Sham-Controlled Trial

    PubMed Central

    Słupska, Lucyna; Paprocka-Borowicz, Małgorzata; Taradaj, Jakub; Bidzińska, Gabriela; Marczyński, Daniel; Cynarska, Aleksandra; Rosińczuk, Joanna

    2015-01-01

    Kinesio taping (KT) may be a new treatment in patients with myofascial trigger points (MTrPs). A new method available for taping practitioners is cross taping (CT). The main objective was to determine how CT, KT, and medical adhesive tape (sham group) affect the subjective assessment of resting bioelectrical activity and pain of the upper trapezius muscle (UT) in patients with MTrPs. 105 volunteers were recruited to participate. The primary outcome was resting bioelectrical activity of UT muscle as assessed by surface electromyography (sEMG) in each group and pain intensity on a visual analog scale (VAS). Assessments were collected before and after intervention and after the 24-hours follow-up. No significant differences were observed in bioelectrical activity of UT between pre-, post-, and follow-up results. In three groups patients had significantly lower pain VAS score after the intervention (CT—p < 0.001, KT—p < 0.001, and sham—p < 0.01). The Kruskal-Wallis ANOVA showed no significant differences in almost all measurements between groups. The application of all three types of tapes does not influence the resting bioelectrical activity of UT muscle and may not lead to a reduction in muscle tone in the case of MTrPs. PMID:26491458

  8. Self-mixing instrument for simultaneous distance and speed measurement

    NASA Astrophysics Data System (ADS)

    Norgia, Michele; Melchionni, Dario; Pesatori, Alessandro

    2017-12-01

    A novel instrument based on Self-mixing interferometry is proposed to simultaneously measure absolute distance and velocity. The measurement method is designed for working directly on each kind of surface, in industrial environment, overcoming also problems due to speckle pattern effect. The laser pump current is modulated at quite high frequency (40 kHz) and the estimation of the induced fringes frequency allows an almost instantaneous measurement (measurement time equal to 25 μs). A real time digital elaboration processes the measurement data and discards unreliable measurements. The simultaneous measurement reaches a relative standard deviation of about 4·10-4 in absolute distance, and 5·10-3 in velocity measurement. Three different laser sources are tested and compared. The instrument shows good performances also in harsh environment, for example measuring the movement of an opaque iron tube rotating under a running water flow.

  9. Evaluation of a new silicone adhesive tape among clinicians caring for patients with fragile or at-risk skin.

    PubMed

    Manriquez, Sonia; Loperfido, Bonnie; Smith, Graham

    2014-04-01

    To evaluate performance of a new silicone tape among clinicians caring for patients with fragile skin. An international, multisite, 2-week-use evaluation. Caregivers (n = 217) from acute care hospitals in the United States, United Kingdom, and France who regularly use tapes on patients with fragile skin. The silicone tape was substituted for current-use gentle tapes for a 2-week trial period. Preuse and postuse questionnaires were collected. The main outcome measure was tape preference. Secondary outcomes included (1) satisfaction with current-use tapes, (2) willingness to replace current-use tapes with silicone tape, (3) performance comparisons between tapes, (4) clinician-reported problems with the silicone tape, and (5) case study information. The sample group consisted of nurses (98.1%), assistants (1.4%), and physicians (0.5%). Hospital units (n = 100) included oncology (31%), medical-surgical (14%), dialysis (12%), infusion/intravenous therapy (16%), critical care (10%), wound care (10%), and other units (7%). Overall preference was 92.0% for the silicone tape, 7.5% for current-use tapes, and 0.5% no preference. Dissatisfaction was 61.2% for current-use tapes, and most clinicians (90.2%) would change to the silicone tape. Evaluators favored (≥71.5%) the silicone tape on 10 performance attributes and on overall performance (91.6%). Most evaluators (75.1%) did not experience problems with the silicone tape, and those who did found problems related to adhesion (77.8%), gentleness (16.0%), and residue (6.2%). These results indicate that the silicone tape fills a performance-expectation gap of current acrylic tapes among users of tapes on patients with fragile or at-risk skin.

  10. Excess current experiment on YBCO tape conductor with metal stabilized layer

    NASA Astrophysics Data System (ADS)

    Tasaki, Kenji; Yazawa, Takashi; Ono, Michitaka; Kuriyama, Toru

    2006-06-01

    Excess current experiments were performed using YBCO tape conductors with a metal stabilized layer on the superconducting layer. The purpose of this research is to obtain the stable criteria of energy dissipation when YBCO tape is forced to flow excess current higher than its critical current. This situation should be considered in power applications. In the experiments short-length samples were immersed in liquid nitrogen and several cycles of 50Hz sinusoidal current were supplied to the samples by an induction voltage regulator. The critical current of the samples was about 110 A. With pulse length as long as 60 ms, YBCO tapes were able to be energized up to twelve times as the critical current without electrical or mechanical deformation. Prior to the excess current experiments, temperature dependency of resistance of the sample was measured so that the temperature rise was estimated by the generated resistance. It is found that YBCO tapes with a copper stabilized layer can be transiently heated to over 400K without degradation.

  11. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  12. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  13. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 5 2013-10-01 2013-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  14. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  15. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 5 2012-10-01 2012-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  16. Relaxation-based distance measurements between a nitroxide and a lanthanide spin label

    NASA Astrophysics Data System (ADS)

    Jäger, H.; Koch, A.; Maus, V.; Spiess, H. W.; Jeschke, G.

    2008-10-01

    Distance measurements by electron paramagnetic resonance techniques between labels attached to biomacromolecules provide structural information on systems that cannot be crystallized or are too large to be characterized by NMR methods. However, existing techniques are limited in their distance range and sensitivity. It is anticipated by theoretical considerations that these limits could be extended by measuring the enhancement of longitudinal relaxation of a nitroxide label due to a lanthanide complex label at cryogenic temperatures. The relaxivity of the dysprosium complex with the macrocyclic ligand DOTA can be determined without direct measurements of longitudinal relaxation rates of the lanthanide and without recourse to model compounds with well defined distance by analyzing the dependence of relaxation enhancement on either temperature or concentration in homogeneous glassy frozen solutions. Relaxivities determined by the two calibration techniques are in satisfying agreement with each other. Error sources for both techniques are examined. A distance of about 2.7 nm is measured in a model compound of the type nitroxide-spacer-lanthanide complex and is found in good agreement with the distance in a modeled structure. Theoretical considerations suggest that an increase of the upper distance limit requires measurements at lower fields and temperatures.

  17. Multiple wavelength interferometry for distance measurements of moving objects with nanometer uncertainty

    NASA Astrophysics Data System (ADS)

    Kuschmierz, R.; Czarske, J.; Fischer, A.

    2014-08-01

    Optical measurement techniques offer great opportunities in diverse applications, such as lathe monitoring and microfluidics. Doppler-based interferometric techniques enable simultaneous measurement of the lateral velocity and axial distance of a moving object. However, there is a complementarity between the unambiguous axial measurement range and the uncertainty of the distance. Therefore, we present an extended sensor setup, which provides an unambiguous axial measurement range of 1 mm while achieving uncertainties below 100 nm. Measurements at a calibration system are performed. When using a pinhole for emulating a single scattering particle, the tumbling motion of the rotating object is resolved with a distance uncertainty of 50 nm. For measurements at the rough surface, the distance uncertainty amounts to 280 nm due to a lower signal-to-noise ratio. Both experimental results are close to the respective Cramér-Rao bound, which is derived analytically for both surface and single particle measurements.

  18. Dynamic frequency-domain interferometer for absolute distance measurements with high resolution

    NASA Astrophysics Data System (ADS)

    Weng, Jidong; Liu, Shenggang; Ma, Heli; Tao, Tianjiong; Wang, Xiang; Liu, Cangli; Tan, Hua

    2014-11-01

    A unique dynamic frequency-domain interferometer for absolute distance measurement has been developed recently. This paper presents the working principle of the new interferometric system, which uses a photonic crystal fiber to transmit the wide-spectrum light beams and a high-speed streak camera or frame camera to record the interference stripes. Preliminary measurements of harmonic vibrations of a speaker, driven by a radio, and the changes in the tip clearance of a rotating gear wheel show that this new type of interferometer has the ability to perform absolute distance measurements both with high time- and distance-resolution.

  19. Conductive sub-layer of twisted-tape-induced swirl-flow heat transfer in vertical circular tubes with various twisted-tape inserts

    NASA Astrophysics Data System (ADS)

    Hata, K.; Fukuda, K.; Masuzaki, S.

    2018-04-01

    Twisted-tape-induced swirl-flow heat transfer due to exponentially increasing heat inputs with various exponential periods ( Q = Q 0 exp(t/τ), τ = 6.04 to 23.07 s) and twisted-tape-induced pressure drop was systematically measured for various mass velocities ( G = 4115 to 13,656 kg/m2 s), inlet liquid temperatures ( T in = 285.88 to 299.09 K), and inlet pressures ( P in = 847.45 to 943.29 kPa) using an experimental water loop flow. Measurements were made over a 59.2-mm effective length and three sections (upper, middle, and lower positions), within which four potential taps were spot-welded onto the outer surface of a 6-mm-inner-diameter, 69.6-mm-heated length, 0.4-mm-thickness platinum circular test tube. Type SUS304 twisted tapes with a width w = 5.6 mm, a thickness δ T = 0.6 mm, a total length l = 372 mm, and twist ratios y = 2.39 and 4.45 were employed in this study. The RANS equations (Reynolds Averaged Navier-Stokes Simulation) with a k-ɛ turbulence model for a circular tube 6 mm in diameter and 636 mm in length were numerically solved for heating of water with a heated section 6 mm in diameter and 70 mm in length using the CFD code, under the same conditions as the experimental ones and considering the temperature dependence of the thermo-physical properties concerned. The theoretical values of surface heat flux q on the circular tubes with twisted tapes with twist ratios y of 2.39 and 4.45 were found to be almost in agreement with the corresponding experimental values of heat flux q, with deviations of less than 30% for the range of temperature difference between the average heater inner surface temperature and the liquid bulk mean temperature ΔT L [ = T s,av - T L , T L = ( T in + T out )/2] considered in this study. The theoretical values of the local surface temperature T s , local average liquid temperature T f,av , and local liquid pressure drop ΔP x were found to be within almost 15% of the corresponding experimental ones. The thickness of the

  20. The effects of therapeutic taping on gross motor function in children with cerebral palsy.

    PubMed

    Footer, Cheryl Burditt

    2006-01-01

    Therapeutic taping to address dysfunctional sitting control in children with cerebral palsy (CP) was investigated in this study. Eighteen children with quadriplegic CP, Gross Motor Function Classification System for Cerebral Palsy levels IV (n = 9) and V (n = 9) participated in the 12-week program. Subjects were assigned randomly to one of two groups: therapeutic taping + physical therapy or physical therapy only. Therapeutic taping was applied for periods of up to 72 hours over the paraspinal region. The effects were assessed with the Gross Motor Function Measure (GMFM-88) at baseline, six weeks, and 12 weeks. A factorial analysis of variance was used to examine group differences over time. No significant differences were found for the GMFM-88 scores between groups over time. Therapeutic taping does not evoke a positive functional change in the seated postural control of children with quadriplegic cerebral palsy. Subjective observation, however, suggested that one child with athetosis benefited from therapeutic taping over the paraspinal region.

  1. The influence of Kinesiology Taping on the reduction of lymphoedema among women after mastectomy – preliminary study

    PubMed Central

    Karczmarek-Borowska, Bożenna; Tymczak, Monika; Hałas, Ireneusz; Banaś, Joanna

    2014-01-01

    Introduction Kinesiology Taping is a method that assists healing processes and improves the physical efficiency. The aim of the study The aim of the study was to assess the influence of Kinesiology Taping on the lymphoedema reduction among women after mastectomy. Material and methods The subject of the research included 44 women underwent single mastectomy along with the removal of lymph nodes. The examination was carried out from the 4th of January to the 4th of February, 2013. The traditional taping method was implemented among 22 women, whereas the own taping method was used among the other 22 women. The therapy took 21 days, during which the tapes were applied three times every 7 days. The measurements were made before every application and at the end of the therapy. In the study, a questionnaire was used and it included questions concerning basic demographic, epidemiological data as well as the evaluation of the therapy effectiveness. The linear measurements of the upper limbs, the measurements of the range of joints’ motion in the upper limb were taken as well as grip strength was made. Results The reduction of the volume of lymphoedema of 55% was reported in the study group, whereas the oedema reduced by 27% in the clinical control one. Conclusions In the reduction of lymphoedema, the greater effectiveness of the own taping method in comparison to the traditional one was reported. Kinesiology Taping exerted an influence on the improvement of the upper limb's joints movability and the grip strength. PMID:24966797

  2. DICOM implementation on online tape library storage system

    NASA Astrophysics Data System (ADS)

    Komo, Darmadi; Dai, Hailei L.; Elghammer, David; Levine, Betty A.; Mun, Seong K.

    1998-07-01

    The main purpose of this project is to implement a Digital Image and Communications (DICOM) compliant online tape library system over the Internet. Once finished, the system will be used to store medical exams generated from U.S. ARMY Mobile ARMY Surgical Hospital (MASH) in Tuzla, Bosnia. A modified UC Davis implementation of DICOM storage class is used for this project. DICOM storage class user and provider are implemented as the system's interface to the Internet. The DICOM software provides flexible configuration options such as types of modalities and trusted remote DICOM hosts. Metadata is extracted from each exam and indexed in a relational database for query and retrieve purposes. The medical images are stored inside the Wolfcreek-9360 tape library system from StorageTek Corporation. The tape library system has nearline access to more than 1000 tapes. Each tape has a capacity of 800 megabytes making the total nearline tape access of around 1 terabyte. The tape library uses the Application Storage Manager (ASM) which provides cost-effective file management, storage, archival, and retrieval services. ASM automatically and transparently copies files from expensive magnetic disk to less expensive nearline tape library, and restores the files back when they are needed. The ASM also provides a crash recovery tool, which enable an entire file system restore in a short time. A graphical user interface (GUI) function is used to view the contents of the storage systems. This GUI also allows user to retrieve the stored exams and send the exams to anywhere on the Internet using DICOM protocols. With the integration of different components of the system, we have implemented a high capacity online tape library storage system that is flexible and easy to use. Using tape as an alternative storage media as opposed to the magnetic disk has the great potential of cost savings in terms of dollars per megabyte of storage. As this system matures, the Hospital Information Systems

  3. Measuring genetic distances between breeds: use of some distances in various short term evolution models

    PubMed Central

    Laval, Guillaume; SanCristobal, Magali; Chevalet, Claude

    2002-01-01

    Many works demonstrate the benefits of using highly polymorphic markers such as microsatellites in order to measure the genetic diversity between closely related breeds. But it is sometimes difficult to decide which genetic distance should be used. In this paper we review the behaviour of the main distances encountered in the literature in various divergence models. In the first part, we consider that breeds are populations in which the assumption of equilibrium between drift and mutation is verified. In this case some interesting distances can be expressed as a function of divergence time, t, and therefore can be used to construct phylogenies. Distances based on allele size distribution (such as (δμ)2 and derived distances), taking a mutation model of microsatellites, the Stepwise Mutation Model, specifically into account, exhibit large variance and therefore should not be used to accurately infer phylogeny of closely related breeds. In the last section, we will consider that breeds are small populations and that the divergence times between them are too small to consider that the observed diversity is due to mutations: divergence is mainly due to genetic drift. Expectation and variance of distances were calculated as a function of the Wright-Malécot inbreeding coefficient, F. Computer simulations performed under this divergence model show that the Reynolds distance [57]is the best method for very closely related breeds. PMID:12270106

  4. 21 CFR 886.1905 - Nystagmus tape.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1905 Nystagmus tape. (a) Identification. Nystagmus tape is a device that is a long, narrow strip of fabric or other flexible material on which a series of objects are...

  5. Casting Of Multilayer Ceramic Tapes

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr.

    1991-01-01

    Procedure for casting thin, multilayer ceramic membranes, commonly called tapes, involves centrifugal casting at accelerations of 1,800 to 2,000 times normal gravitational acceleration. Layers of tape cast one at a time on top of any previous layer or layers. Each layer cast from slurry of ground ceramic suspended in mixture of solvents, binders, and other components. Used in capacitors, fuel cells, and electrolytic separation of oxygen from air.

  6. 23 CFR 750.103 - Measurements of distance.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 23 Highways 1 2012-04-01 2012-04-01 false Measurements of distance. 750.103 Section 750.103 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RIGHT-OF-WAY AND ENVIRONMENT HIGHWAY BEAUTIFICATION National Standards for Regulation by States of Outdoor Advertising Adjacent to the Interstate...

  7. A case for automated tape in clinical imaging.

    PubMed

    Bookman, G; Baune, D

    1998-08-01

    Electronic archiving of radiology images over many years will require many terabytes of storage with a need for rapid retrieval of these images. As more large PACS installations are installed and implemented, a data crisis occurs. The ability to store this large amount of data using the traditional method of optical jukeboxes or online disk alone becomes an unworkable solution. The amount of floor space number of optical jukeboxes, and off-line shelf storage required to store the images becomes unmanageable. With the recent advances in tape and tape drives, the use of tape for long term storage of PACS data has become the preferred alternative. A PACS system consisting of a centrally managed system of RAID disk, software and at the heart of the system, tape, presents a solution that for the first time solves the problems of multi-modality high end PACS, non-DICOM image, electronic medical record and ADT data storage. This paper will examine the installation of the University of Utah, Department of Radiology PACS system and the integration of automated tape archive. The tape archive is also capable of storing data other than traditional PACS data. The implementation of an automated data archive to serve the many other needs of a large hospital will also be discussed. This will include the integration of a filmless cardiology department and the backup/archival needs of a traditional MIS department. The need for high bandwidth to tape with a large RAID cache will be examined and how with an interface to a RIS pre-fetch engine, tape can be a superior solution to optical platters or other archival solutions. The data management software will be discussed in detail. The performance and cost of RAID disk cache and automated tape compared to a solution that includes optical will be examined.

  8. Effects of Patellofemoral Taping on Patellofemoral Joint Alignment and Contact Area During Weight Bearing.

    PubMed

    Ho, Kai-Yu; Epstein, Ryan; Garcia, Ron; Riley, Nicole; Lee, Szu-Ping

    2017-02-01

    Study Design Controlled laboratory study. Background Although it has been theorized that patellofemoral joint (PFJ) taping can correct patellar malalignment, the effects of PFJ taping techniques on patellar alignment and contact area have not yet been studied during weight bearing. Objective To examine the effects of 2 taping approaches (Kinesio and McConnell) on PFJ alignment and contact area. Methods Fourteen female subjects with patellofemoral pain and PFJ malalignment participated. Each subject underwent a pretaping magnetic resonance imaging (MRI) scan session and 2 MRI scan sessions after the application of the 2 taping techniques, which aimed to correct lateral patellar displacement. Subjects were asked to report their pain level prior to each scan session. During MRI assessment, subjects were loaded with 25% of body weight on their involved/more symptomatic leg at 0°, 20°, and 40° of knee flexion. The outcome measures included patellar lateral displacement (bisect-offset [BSO] index), mediolateral patellar tilt angle, patellar height (Insall-Salvati ratio), contact area, and pain. Patellofemoral joint alignment and contact area were compared among the 3 conditions (no tape, Kinesio, and McConnell) at 3 knee angles using a 2-factor, repeated-measures analysis of variance. Pain was compared among the 3 conditions using the Friedman test and post hoc Wilcoxon signed-rank tests. Results Our data did not reveal any significant effects of either McConnell or Kinesio taping on the BSO index, patellar tilt angle, Insall-Salvati ratio, or contact area across the 3 knee angles, whereas knee angle had a significant effect on the BSO index and contact area. A reduction in pain was observed after the application of the Kinesio taping technique. Conclusion In a weight-bearing condition, this preliminary study did not support the use of PFJ taping as a medial correction technique to alter the PFJ contact area or alignment of the patella. J Orthop Sports Phys Ther 2017

  9. Playback Station #2 for Cal Net and 5-day-recorder tapes

    USGS Publications Warehouse

    Eaton, Jerry P.

    1978-01-01

    A second system (Playback Station #2) has been set up to play back Cal Net 1" tapes and 5-day-recorder 1/2" tapes. As with the first playback system (Playback Station #1) the tapes are played back on a Bell and Howell VR3700B tape deck and the records are written out on a 16-channel direct-writing Siemens "0scillomink." Separate reproduce heads, tape guides, and tape tension sensor rollers are required for playing back 111 tapes and 1/2" tapes, but changing these tape deck components is a simple task that requires only a few minutes. The discriminators, patch panels, selector switches, filters, time code translators, and signal conditioning circuits for the time code translators and for the tape-speed-compensation signal are all mounted in an equipment rack that stands beside the playback tape deck. Changing playback speeds (15/16 ips or 3 3/4 ips) or changing from Cal Net tapes to 5-day-recorder tapes requires only flipping a few switches and/or changing a few patch cables on the patch panel (in addition to changing the reproduce heads, etc., to change from 1" tape to 1/2" tape). For the Cal Net tapes, the system provides for playback of 9 data channels (680 Hz thru 3060 Hz plus 400 Hz) and 3 time signals (IRIG-E, IRIG-C, and WWVB) at both 15/16 ips (x1 speed) and 3 3/4 ips (x4 speed). Available modes of compensation (using either a 4688 Hz reference or a 3125 Hz reference) are subtractive, capstan, capstan plus subtractive, or no compensation.

  10. The correction of vibration in frequency scanning interferometry based absolute distance measurement system for dynamic measurements

    NASA Astrophysics Data System (ADS)

    Lu, Cheng; Liu, Guodong; Liu, Bingguo; Chen, Fengdong; Zhuang, Zhitao; Xu, Xinke; Gan, Yu

    2015-10-01

    Absolute distance measurement systems are of significant interest in the field of metrology, which could improve the manufacturing efficiency and accuracy of large assemblies in fields such as aircraft construction, automotive engineering, and the production of modern windmill blades. Frequency scanning interferometry demonstrates noticeable advantages as an absolute distance measurement system which has a high precision and doesn't depend on a cooperative target. In this paper , the influence of inevitable vibration in the frequency scanning interferometry based absolute distance measurement system is analyzed. The distance spectrum is broadened as the existence of Doppler effect caused by vibration, which will bring in a measurement error more than 103 times bigger than the changes of optical path difference. In order to decrease the influence of vibration, the changes of the optical path difference are monitored by a frequency stabilized laser, which runs parallel to the frequency scanning interferometry. The experiment has verified the effectiveness of this method.

  11. The accuracy of the plusoptiX for measuring pupillary distance.

    PubMed

    Singman, Eric; Matta, Noelle; Tian, Jing; Silbert, David

    2014-03-01

    The plusoptiX photoscreener provides a number of measurements, including an estimate of inter-pupillary distance. We compare the plusoptiX photoscreening measurements of pupillary distance to that of an experienced optician in order to measure the accuracy of this reading. A retrospective chart review was done on 731 patients ranging in age from 1 to 16 years. Of these, 256 patients had both a plusoptiX photoscreening and a pupillary distance measurement by one of our office opticians. Of the 236 patients evaluated, 142 were orthophoric, 97 were esotropic, and 17 were exotropic. The mean absolute difference for the entire group between the two measurements was 0.3 mm. For the orthophoric patients, this metric was 0.3 mm, while for the esotropic patients it was 0.8 mm. There were too few exotropic patients to obtain reliable statistics. Although the average difference between the optician's measurements and those provided by the plusoptiX was within 0.5 mm for orthophoric patients, the variability of the measurements provided by the plusoptiX was too great to permit us to recommend the device as an alternative to the optician for routinely dispensing spectacles.

  12. Geometric model of pseudo-distance measurement in satellite location systems

    NASA Astrophysics Data System (ADS)

    Panchuk, K. L.; Lyashkov, A. A.; Lyubchinov, E. V.

    2018-04-01

    The existing mathematical model of pseudo-distance measurement in satellite location systems does not provide a precise solution of the problem, but rather an approximate one. The existence of such inaccuracy, as well as bias in measurement of distance from satellite to receiver, results in inaccuracy level of several meters. Thereupon, relevance of refinement of the current mathematical model becomes obvious. The solution of the system of quadratic equations used in the current mathematical model is based on linearization. The objective of the paper is refinement of current mathematical model and derivation of analytical solution of the system of equations on its basis. In order to attain the objective, geometric analysis is performed; geometric interpretation of the equations is given. As a result, an equivalent system of equations, which allows analytical solution, is derived. An example of analytical solution implementation is presented. Application of analytical solution algorithm to the problem of pseudo-distance measurement in satellite location systems allows to improve the accuracy such measurements.

  13. Systematic Review of the Effect of Taping Techniques on Patellofemoral Pain Syndrome.

    PubMed

    Logan, Catherine A; Bhashyam, Abhiram R; Tisosky, Ashley J; Haber, Daniel B; Jorgensen, Anna; Roy, Adam; Provencher, Matthew T

    Taping is commonly used in the management of several musculoskeletal conditions, including patellofemoral pain syndrome (PFPS). Specific guidelines for taping are unknown. To investigate the efficacy of knee taping in the management of PFPS. Our hypothesis was that tension taping and exercise would be superior to placebo taping and exercise as well as to exercise or taping alone. The PubMed/MEDLINE, Cochrane, Rehabilitation and Sports Medicine Source, and CINAHL databases were reviewed for English-language randomized controlled trials (RCTs) evaluating the efficacy of various taping techniques that were published between 1995 and April 2015. Keywords utilized included taping, McConnell, kinesio-taping, kinesiotaping, patellofemoral pain, and knee. Studies included consisted of RCTs (level 1 or 2) with participants of all ages who had anterior knee or patellofemoral pain symptoms and had received nonsurgical management using any taping technique. Systematic review. Level 2. A checklist method was used to determine selection, performance, detection, and attrition bias for each article. A quality of evidence grading was then referenced using the validated PEDro database for RCTs. Three difference comparison groups were compared: tension taping and exercise versus placebo taping and exercise (group 1), placebo taping and exercise versus exercise alone (group 2), and tension taping and exercise versus taping alone (group 3). Five RCTs with 235 total patients with multiple intervention arms were included. Taping strategies included McConnell and Kinesiotaping. Visual analog scale (VAS) scores indicated improvement in all 3 comparison groups (group 1: 91 patients, 39% of total, mean VAS improvement 44.9 [tension taping + exercise] vs 66 [placebo taping + exercise]; group 2: 56 patients, 24% of total, mean VAS improvement 66 [placebo taping + exercise] vs 47.6 [exercise alone]; and group 3: 112 patients, 48% of total, mean VAS improvement 44.9 [tension taping + exercise

  14. Comparison of acrylic polymer adhesive tapes and silicone optical grease in light sharing detectors for positron emission tomography.

    PubMed

    Van Elburg, Devin J; Noble, Scott D; Hagey, Simone; Goertzen, Andrew L

    2018-02-26

    Optical coupling is an important factor in detector design as it improves optical photon transmission by mitigating internal reflections at light-sharing boundaries. In this work we compare optical coupling materials, namely double-sided acrylic polymer tapes and silicone optical grease (SiG), in the context of positron emission tomography. Four double-sided tapes from 3 M of varying thicknesses (0.229 mm-1.016 mm) and adhesive materials ('100MP', 'A100', and 'GPA') were characterized with spectrophotometer measurements as well as photopeak amplitude and energy resolution measurements using lutetium-yttrium oxy-orthosilicate (LYSO) coupled to photomultiplier tubes (PMT) or silicon photomultipliers (SiPMs). Transmission spectra from the spectrophotometer showed over 80% transmission for all tapes at 420 nm and above, with 89.6% and 88.8% transmission for the 0.508 mm and 1.016 mm thick GPA tapes, respectively, at 420 nm. Measurements with single-pixel LYSO-PMT and 4  ×  4 array (one-to-one coupled) LYSO-SiPM setups determined that SiG had the greatest photopeak amplitude, with tapes showing 2.1%-14.8% reduction in photopeak amplitude with respect to SiG. Energy resolution changed by less than 4% on a relative basis between tapes and SiG with PMT measurements, however for the SiPM array measurements the energy resolution improved from 15.6%  ±  2.7% full-width at half-maximum to 11.4%  ±  1.2% for SiG and 1 mm GPA respectively. Data acquired with dual-layer offset LYSO arrays (light sharing detector designs) demonstrated that a detector coupled with 1 mm thick GPA tape produced equivalent detector flood histograms to those from a design coupled with SiG and a 1 mm thick glass lightguide. No significant degradation in photopeak amplitude and energy resolution was observed over five months of measurements, indicating the tapes maintain their coupling integrity over several months. Though minimal photopeak amplitude degradation

  15. Comparison of acrylic polymer adhesive tapes and silicone optical grease in light sharing detectors for positron emission tomography

    NASA Astrophysics Data System (ADS)

    Van Elburg, Devin J.; Noble, Scott D.; Hagey, Simone; Goertzen, Andrew L.

    2018-03-01

    Optical coupling is an important factor in detector design as it improves optical photon transmission by mitigating internal reflections at light-sharing boundaries. In this work we compare optical coupling materials, namely double-sided acrylic polymer tapes and silicone optical grease (SiG), in the context of positron emission tomography. Four double-sided tapes from 3 M of varying thicknesses (0.229 mm-1.016 mm) and adhesive materials (‘100MP’, ‘A100’, and ‘GPA’) were characterized with spectrophotometer measurements as well as photopeak amplitude and energy resolution measurements using lutetium-yttrium oxy-orthosilicate (LYSO) coupled to photomultiplier tubes (PMT) or silicon photomultipliers (SiPMs). Transmission spectra from the spectrophotometer showed over 80% transmission for all tapes at 420 nm and above, with 89.6% and 88.8% transmission for the 0.508 mm and 1.016 mm thick GPA tapes, respectively, at 420 nm. Measurements with single-pixel LYSO-PMT and 4  ×  4 array (one-to-one coupled) LYSO-SiPM setups determined that SiG had the greatest photopeak amplitude, with tapes showing 2.1%-14.8% reduction in photopeak amplitude with respect to SiG. Energy resolution changed by less than 4% on a relative basis between tapes and SiG with PMT measurements, however for the SiPM array measurements the energy resolution improved from 15.6%  ±  2.7% full-width at half-maximum to 11.4%  ±  1.2% for SiG and 1 mm GPA respectively. Data acquired with dual-layer offset LYSO arrays (light sharing detector designs) demonstrated that a detector coupled with 1 mm thick GPA tape produced equivalent detector flood histograms to those from a design coupled with SiG and a 1 mm thick glass lightguide. No significant degradation in photopeak amplitude and energy resolution was observed over five months of measurements, indicating the tapes maintain their coupling integrity over several months. Though minimal photopeak amplitude

  16. Inter-rater Reliability of Real-Time Ultrasound to Measure Acromiohumeral Distance.

    PubMed

    Mackenzie, Tanya Anne; Bdaiwi, Alya H; Herrington, Lee; Cools, Ann

    2016-07-01

    Real-time ultrasound (RTUS) has been suggested as a reliable measure of acromiohumeral distance. However, to date, no vigorous assessment and reporting of inter-rater reliability of this method has been performed with the shoulder in a neutral position or with active and passive arm abduction. To assess intrasession inter-rater reliability of using RTUS to measure acromiohumeral distance with the shoulder in a neutral position and with 60° active and passive abduction. Inter-rater intrasession reliability of repeated measures. Human performance laboratory. Twenty persons (12 male and 8 female) with an average age of 29.86 years (standard deviation, 7.8). In an inter-rater, intrasession study, RTUS was used to measure the acromiohumeral distance with the shoulder in a neutral position and with 60° of both active and passive abduction. Acromiohumeral distance. Intraclass correlation coefficient (ICC)2.1 scores ranged between 0.65-0.88 (standard error of the mean = 0.81-1.2 mm and minimal detectable differences with 95% confidence = 2.2-2.3 mm) for inter-rater intrasession reliability. RTUS was found to have fair to good inter-rater reliability as a tool to measure acromiohumeral distance with the shoulder in a neutral position and with 60° of both active and passive arm abduction. Copyright © 2016 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  17. Aligned Carbon Nanotube Tape for Sensor Applications

    NASA Technical Reports Server (NTRS)

    Tucker, Dennis S.

    2013-01-01

    For this effort, will concentrate on three applications: Vibration Gyroscope utilizes piezoelectric properties of the tape and Coriolis effect Accelerometer utilizes the piezoresistive property Strain Gauge utilizes piezoresistive property Accelerometer and Strain Gauge can also utilize piezoelectric effect Test piezoelectric properties using facilities at the Microfabrication Laboratory (AMRDEC) . Enhance piezoelectric effect using polyvinylidine fluoride and P(VDF ]TrFE) which is readily polarizable .Spray matrix solution while winding fiber; Sandwich of CNT tape and PVDF film (DOE .Two Level) . Construct and test prototype vibration gyroscope . Construct and test prototype accelerometer using cantilever design . Test strain sensitivity of CNT tape against industrial strain gauge . Embed CNT tape in composite samples as well as on surface and test to failure (4 ]point bend) A piezoelectric device exhibits an electrical response from a mechanical applied stress. . A piezoelectric device has both capacitance and resistance properties in which by applying an electric field from a waveform will exert a mechanical stress that can be monitored for a response. . The typical waveform applied is a sinusoidal waveform of a defined voltage for a defined period. The defined voltage is driven from 0 volts to the positive defined volts then back to 0 and driven to negative defined volts then back to 0. . Example. Vmax set to 10V and period set to 10 ms. . Voltage will start at zero, go to 10 volts, return to zero, go to ]10 volts and return to zero during 10 ms. . Applying this electrical field to a DUT, the capacitance response and resistance response can be observed. CNT tape is easier to manufacture and cheaper than micromachining silicon or other ceramic piezoelectric used in gyroscopes and accelerometers CNT tape properties can be modified during manufacture for specific application CNT tape has enhanced mechanical and thermal properties in addition to unique electrical

  18. TMR tape drive for a 15 TB cartridge

    NASA Astrophysics Data System (ADS)

    Biskeborn, Robert G.; Fontana, Robert E.; Lo, Calvin S.; Czarnecki, W. Stanley; Liang, Jason; Iben, Icko E. T.; Decad, Gary M.; Hipolito, Venus A.

    2018-05-01

    This paper highlights the development of tunnel magnetoresistive (TMR) sensors for magnetic tape recording applications. This has led to the introduction of a tape drives supporting a 15 TB native tape cartridge, currently the highest capacity available. Underscoring this development is the fact that the TMR sensors must run in continual contact with the tape media. This is contrasted with modern hard disk drive (hdd) sensors, which fly above the disk platters. Various challenges encountered in developing and deploying TMR are presented. In addition, advances to the write transducer are also discussed. Lastly, the authors show that future density scaling for tape recording, unlike that for hdd, is not facing limits imposed by photolithography or superparamagnetic physics, suggesting that cartridge capacity improvements of 4 to 6x will be achieved in the next 4 to 8 years.

  19. Survey of Scientific-Technical Tape Services.

    ERIC Educational Resources Information Center

    Carroll, Kenneth D., Ed.

    The results of a survey of commercially available tape services which can provide libraries and information centers with data bases of scientific and technical literature are reported. During the past few years there has been an increasing number of tape services entering the information resources market. Each of these services makes available to…

  20. Multiple Generations on Video Tape Recorders.

    ERIC Educational Resources Information Center

    Wiens, Jacob H.

    Helical scan video tape recorders were tested for their dubbing characteristics in order to make selection data available to media personnel. The equipment, two recorders of each type tested, was submitted by the manufacturers. The test was designed to produce quality evaluations for three generations of a single tape, thereby encompassing all…

  1. Using Ankle Bracing and Taping to Decrease Range of Motion and Velocity During Inversion Perturbation While Walking

    PubMed Central

    Hall, Emily A.; Simon, Janet E.; Docherty, Carrie L.

    2016-01-01

    Context:  Prophylactic ankle supports are commonly used. However, the effectiveness of external supports in preventing an inversion stress has been debated. Objective:  To evaluate how ankle bracing and taping affect inversion range of motion, time to maximum inversion, inversion velocity, and perceived ankle stability compared with a control condition during a dynamic inversion perturbation while walking. Design:  Crossover study. Setting:  Research laboratory. Patients or Other Participants:  A total of 42 physically active participants (16 men, 26 women; age = 21.2 ± 3.3 years, height = 168.9 ± 8.9 cm, mass = 66.1 ± 11.4 kg) volunteered. Intervention(s):  Participants walked on a custom-built walkway that suddenly inverted their ankles to 30° in 3 conditions: brace, tape, and control (no external support). We used an ASO ankle brace for the brace condition and a closed basketweave technique for the tape condition. Three trials were completed for each condition. Main Outcome Measure(s):  Maximum inversion (degrees), time to maximum inversion (milliseconds), and inversion velocity (degrees per second) were measured using an electrogoniometer, and perceived stability (centimeters) was measured using a visual analog scale. Results:  Maximum inversion decreased more in the brace condition (20.1°) than in the control (25.3°) or tape (22.3°) conditions (both P values = .001), and the tape condition restricted inversion more than the control condition (P = .001). Time to maximum inversion was greater in the brace condition (143.5 milliseconds) than in the control (123.7 milliseconds; P = .001) or tape (130.7 milliseconds; P = .009) conditions and greater in the tape than in the control condition (P = .02). Inversion velocity was slower in the brace condition (142.6°/s) than in the control (209.1°/s) or tape (174.3°/s) conditions (both P values = .001) and slower in the tape than in the control condition (P = .001). Both the brace and tape

  2. Editing of EIA coded, numerically controlled, machine tool tapes

    NASA Technical Reports Server (NTRS)

    Weiner, J. M.

    1975-01-01

    Editing of numerically controlled (N/C) machine tool tapes (8-level paper tape) using an interactive graphic display processor is described. A rapid technique required for correcting production errors in N/C tapes was developed using the interactive text editor on the IMLAC PDS-ID graphic display system and two special programs resident on disk. The correction technique and special programs for processing N/C tapes coded to EIA specifications are discussed.

  3. Subsurface Supergranular Vertical Flows as Measured Using Large Distance Separations in Time-Distance Helioseismology

    NASA Technical Reports Server (NTRS)

    Duvall, T. L., Jr.; Hanasoge, S. M.

    2012-01-01

    As large-distance rays (say, 10-24 deg) approach the solar surface approximately vertically, travel times measured from surface pairs for these large separations are mostly sensitive to vertical flows, at least for shallow flows within a few Mm of the solar surface. All previous analyses of supergranulation have used smaller separations and have been hampered by the difficulty of separating the horizontal and vertical flow components. We find that the large separation travel times associated with upergranulation cannot be studied using the standard phase-speed filters of time-distance helioseismology. These filters, whose use is based upon a refractive model of the perturbations,reduce the resultant travel time signal by at least an order of magnitude at some distances. More effective filters are derived. Modeling suggests that the center-annulus travel time difference in the separation range 10-24 deg is insensitive to the horizontally diverging flow from the centers of the supergranules and should lead to a constant signal from the vertical flow. Our measurement of this quantity for the average supergranule, 5.1 s, is constant over the distance range. This magnitude of signal cannot be caused by the level of upflow at cell centers seen at the photosphere of 10 m/s extended in depth. It requires the vertical flow to increase with depth. A simple Gaussian model of the increase with depth implies a peak upward flow of 240 m/s at a depth of 2.3 Mm and a peak horizontal flow of 700 m/s at a depth of 1.6 Mm.

  4. Improving the Spacelab mass memory unit tape layout with a simulation model

    NASA Technical Reports Server (NTRS)

    Noneman, S. R.

    1984-01-01

    A tape drive called the Mass Memory Unit (MMU) stores software used by Spacelab computers. MMU tape motion must be minimized during typical flight operations to avoid a loss of scientific data. A projection of the tape motion is needed for evaluation of candidate tape layouts. A computer simulation of the scheduled and unscheduled MMU tape accesses is developed for this purpose. This simulation permits evaluations of candidate tape layouts by tracking and summarizing tape movements. The factors that affect tape travel are investigated and a heuristic is developed to find a good tape layout. An improved tape layout for Spacelab I is selected after the evaluation of fourteen candidates. The simulation model will provide the ability to determine MMU layouts that substantially decrease the tape travel on future Spacelab flights.

  5. Getting in Taped, Part I and Part II

    ERIC Educational Resources Information Center

    Cundy, H. M.; Higgins, J.

    1971-01-01

    This article is in two parts: discussion of mathematical concepts involved in converting the reading from the tape-recorder counter which counts the turns of the run-off spool to that from the counter which counts turns of the take-up spool; calculating the length of tape run off when given the reading from the tape-recorder counter of the run-off…

  6. Measuring Self-Regulation in Self-Paced Open and Distance Learning Environments

    ERIC Educational Resources Information Center

    Kocdar, Serpil; Karadeniz, Abdulkadir; Bozkurt, Aras; Buyuk, Koksal

    2018-01-01

    Previous studies have described many scales for measuring self-regulation; however, no scale has been developed specifically for self-paced open and distance learning environments. Therefore, the aim of this study is to develop a scale for determining the self-regulated learning skills of distance learners in selfpaced open and distance learning…

  7. Magnetic tape

    NASA Technical Reports Server (NTRS)

    Robinson, Harriss

    1992-01-01

    The move to visualization and image processing in data systems is increasing the demand for larger and faster mass storage systems. The technology of choice is magnetic tape. This paper briefly reviews the technology past, present, and projected. A case is made for standards and the value of the standards to users.

  8. Effect of tape stripping and adjuvants on immune response after intradermal DNA electroporation.

    PubMed

    Vandermeulen, Gaëlle; Daugimont, Liévin; Richiardi, Hervé; Vanderhaeghen, Marie-Lise; Lecouturier, Nathalie; Ucakar, Bernard; Préat, Véronique

    2009-07-01

    DNA vaccines require both efficient delivery methods and appropriate adjuvants. Based on their mechanisms of action, we hypothesised that some adjuvants could enhance vaccine immunogenicity or direct the response towards Th1 profile after intradermal DNA electroporation. After intradermal electroporation of plasmid DNA encoding luciferase, mice received hyaluronidase, imiquimod, monophosphoryl lipid A or were tape stripped in order to modulate the immune response against the encoded protein. We measured total immunoglobulin G, IgG1, IgG2a titres and the cytokines produced by splenocyte cultures to assess both humoral and cellular response. The effect of tape stripping on the response against intradermally delivered ovalbumin protein was also assessed. Neither hyaluronidase nor imiquimod improved the immune response against the encoded luciferase. Monophosphoryl lipid A did not modify the cytokines production but increased the anti-luciferase IgG2a titres. Tape stripping significantly increased anti-luciferase IgG2a and IFN-gamma responses. It also enhanced the humoral response after intradermal injection of the ovalbumin protein. Tape stripping is able to increase the Th1 immune response against both DNA and protein vaccines. Therefore, tape stripping appears to have interesting adjuvant effect on intradermal vaccination.

  9. Measuring short distance dispersal of Alliaria petiolata and determining potential long distance dispersal mechanisms

    PubMed Central

    Anderson, Roger C.

    2018-01-01

    Introduction Alliaria petiolata, an herbaceous plant, has invaded woodlands in North America. Its ecology has been thoroughly studied, but an overlooked aspect of its biology is seed dispersal distances and mechanisms. We measured seed dispersal distances in the field and tested if epizoochory is a potential mechanism for long-distance seed dispersal. Methods Dispersal distances were measured by placing seed traps in a sector design around three seed point sources, which consisted of 15 second-year plants transplanted within a 0.25 m radius circle. Traps were placed at intervals ranging from 0.25–3.25 m from the point source. Traps remained in the field until a majority of seeds were dispersed. Eight probability density functions were fitted to seed trap counts via maximum likelihood. Epizoochory was tested as a potential seed dispersal mechanism for A. petiolata through a combination of field and laboratory experiments. To test if small mammals transport A. petiolata seeds in their fur, experimental blocks were placed around dense A. petiolata patches. Each block contained a mammal inclusion treatment (MIT) and control. The MIT consisted of a wood-frame (31 × 61× 31 cm) covered in wire mesh, except for the two 31 × 31 cm ends, placed over a germination tray filled with potting soil. A pan filled with bait was placed in the center of the tray. The control frame (11 × 31 × 61 cm) was placed over a germination tray and completely covered in wire mesh to exclude animal activity. Treatments were in the field for peak seed dispersal. In March, trays were moved to a greenhouse and A. petiolata seedlings were counted and then compared between treatments. To determine if A. petiolata seeds attach to raccoon (Procyon lotor) and white-tailed deer (Odocoileus virginianus) fur, wet and dry seeds were dropped onto wet and dry fur. Furs were rotated 180 degrees and the seeds that remained attached were counted. To measure seed retention, seeds were dropped on

  10. Effects of low-dye taping on plantar pressure pre and post exercise: an exploratory study.

    PubMed

    Nolan, Damien; Kennedy, Norelee

    2009-04-21

    Low-Dye taping is used for excessive pronation at the subtalar joint of the foot. Previous research has focused on the tape's immediate effect on plantar pressure. Its effectiveness following exercise has not been investigated. Peak plantar pressure distribution provides an indirect representation of subtalar joint kinematics. The objectives of the study were 1) To determine the effects of Low-Dye taping on peak plantar pressure immediately post-application. 2) To determine whether any initial effects are maintained following exercise. 12 asymptomatic subjects participated; each being screened for excessive pronation (navicular drop > 10 mm). Plantar pressure data was recorded, using the F-scan, at four intervals during the testing session: un-taped, baseline-taped, post-exercise session 1, and post-exercise session 2. Each exercise session consisted of a 10-minute walk at a normal pace. The foot was divided into 6 regions during data analysis. Repeated-measures analysis of variance (ANOVA) was used to assess regional pressure variations across the four testing conditions. Reduced lateral forefoot peak plantar pressure was the only significant difference immediately post tape application (p = 0.039). This effect was lost after 10 minutes of exercise (p = 0.036). Each exercise session resulted in significantly higher medial forefoot peak pressure compared to un-taped; (p = 0.015) and (p = 0.014) respectively, and baseline-taped; (p = 0.036) and (p = 0.015) respectively. Medial and lateral rearfoot values had also increased after the second session (p = 0.004), following their non-significant reduction at baseline-taped. A trend towards a medial-to-lateral shift in pressure present in the midfoot immediately following tape application was still present after 20 minutes of exercise. Low-Dye tape's initial effect of reduced lateral forefoot peak plantar pressure was lost after a 10-minute walk. However, the tape continued to have an effect on the medial forefoot after

  11. High-performance multi-channel fiber-based absolute distance measuring interferometer system

    NASA Astrophysics Data System (ADS)

    Deck, Leslie L.

    2009-08-01

    I describe the principle of operation and performance of a fiber-based absolute distance measuring interferometer system with 60 independent simultaneous channels. The system was designed for demanding applications requiring passive, electrically immune sensors with an extremely long MTTF. In addition to providing better than 0.3nm measurement repeatability at 5KHz for all channels, the system demonstrated absolute distance uncertainty of less than 5nm over a 500 micron measurement range.

  12. Fabrication of Polyimide-Matrix/Carbon and Boron-Fiber Tape

    NASA Technical Reports Server (NTRS)

    Belvin, Harry L.; Cano, Roberto J.; Treasure, Monte; Shahood, Thomas W.

    2007-01-01

    The term HYCARB denotes a hybrid composite of polyimide matrices reinforced with carbon and boron fibers. HYCARB and an improved process for fabricating dry HYCARB tapes have been invented in a continuing effort to develop lightweight, strong composite materials for aerospace vehicles. Like other composite tapes in this line of development, HYCARB tapes are intended to be used to build up laminated structures having possibly complex shapes by means of automated tow placement (ATP) - a process in which a computer-controlled multiaxis machine lays down prepreg tape or tows. The special significance of the present process for making dry HYCARB for ATP is that it contributes to the reduction of the overall cost of manufacturing boron-reinforced composite-material structures while making it possible to realize increased compression strengths. The present process for making HYCARB tapes incorporates a "wet to dry" process developed previously at Langley Research Center. In the "wet to dry" process, a flattened bundle of carbon fiber tows, pulled along a continuous production line between pairs of rollers, is impregnated with a solution of a poly(amide acid) in N-methyl-2-pyrrolidinone (NMP), then most of the NMP is removed by evaporation in hot air. In the present case, the polyamide acid is, more specifically, that of LaRC. IAX (or equivalent) thermoplastic polyimide, and the fibers are, more specifically, Manganite IM7 (or equivalent) polyacrylonitrile- based carbon filaments that have a diameter of 5.2 m and are supplied in 12,000-filament tows. The present process stands in contrast to a prior process in which HYCARB tape was made by pressing boron fibers into the face of a wet carbon-fiber/ poly(amide acid) prepreg tape . that is, a prepreg tape from which the NMP solvent had not been removed. In the present process, one or more layer(s) of side-by-side boron fibers are pressed between dry prepreg tapes that have been prepared by the aforementioned gwet to dry h

  13. Kinesthetic taping improves walking function in patients with stroke: a pilot cohort study.

    PubMed

    Boeskov, Birgitte; Carver, Line Tornehøj; von Essen-Leise, Anders; Henriksen, Marius

    2014-01-01

    Stroke is an important cause of severe disability and impaired motor function. Treatment modalities that improve motor function in patients with stroke are needed. The objective of this study was to investigate the effect of kinesthetic taping of the anterior thigh and knee on maximal walking speed and clinical indices of spasticity in patients with stroke. Thirty-two patients (9 women) receiving rehabilitation after stroke (average, 50 days since stroke) who had impaired walking ability were recruited. Primary outcome was maximal walking speed measured by the 10-meter walk test. Secondary outcomes were number of steps taken during the test and clinical signs of spasticity measured by the Tardieu Scale. Tests were conducted before and immediately after application of kinesthetic tape to the anterior thigh and knee of the paretic lower limb. After application of the tape, the maximal walking speed increased, on average, by 0.08 m/s (95% CI, 0.04 to 0.12; P < .0001). The number of steps taken during the test was significantly decreased by 1.4 steps (95% CI, -2.3 to -0.5; P < .0031). The Tardieu scores were not significantly changed by the tape intervention, although a trend was observed indicating a lesser degree of spasticity. The results of this study indicate that kinesthetic taping of the anterior thigh and knee provides an immediate improvement in walking function in patients with stroke. Such a positive effect on motor function could be a valuable adjunct in physical therapy and rehabilitation of patients with stroke.

  14. GSFC specification electronic data processing magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Tinari, D. F.; Perry, J. L.

    1980-01-01

    The design requirements are given for magnetic oxide coated, electronic data processing tape, wound on reels. Magnetic recording tape types covered by this specification are intended for use on digital tape transports using the Non-Return-to-Zero-change-on-ones (NRZI) recording method for recording densities up to and including 800 characters per inch (cpi) and the Phase-Encoding (PE) recording method for a recording density of 1600 cpi.

  15. Subsurface Supergranular Vertical Flows as Measured Using Large Distance Separations in Time-Distance Helioseismology

    NASA Technical Reports Server (NTRS)

    Duvall, Thomas L., Jr.; Hanasoge, S. M.

    2012-01-01

    As large-distance rays (say, 10 - 24deg) approach the solar surface approximately vertically, travel times measured from surface pairs for these large separations are mostly sensitive to vertical flows, at least for shallow flows within a few Mm of the solar surface. All previous analyses of supergranulation have used smaller separations and have been hampered by the difficulty of separating the horizontal and vertical flow components. We find that the large-separation travel times associated with supergranulation cannot be studied using the standard phase-speed filters of time-distance helioseismology. These filters, whose use is based upon a refractive model of the perturbations, reduce the resultant travel time signal by at least an order of magnitude at some distances. More effective filters are derived. Modeling suggests that the center-annulus travel-time difference [outward-going time minus inward-going time] in the separation range delta= 10 - 24deg is insensitive to the horizontally diverging flow from the centers of the supergranules and should lead to a constant signal from the vertical flow. Our measurement of this quantity, 5.1+/-0.1 seconds, is constant over the distance range. This magnitude of the signal cannot be caused by the level of upflow at cell centers seen at the photosphere of 10 ms(exp-1) extended in depth. It requires the vertical flow to increase with depth. A simple Gaussian model of the increase with depth implies a peak upward flow of 240 ms(exp-1) at a depth of 2.3 Mm and a peak horizontal flow of 700 ms(exp-1) at a depth of 1.6 Mm.

  16. OCLC-MARC Tape Processing: A Functional Analysis.

    ERIC Educational Resources Information Center

    Miller, Bruce Cummings

    1984-01-01

    Analyzes structure of, and data in, the OCLC-MARC record in the form delivered via OCLC's Tape Subscription Service, and outlines important processing functions involved: "unreadable tapes," duplicate records and deduping, match processing, choice processing, locations processing, "automatic" and "input" stamps,…

  17. Mode-resolved frequency comb interferometry for high-accuracy long distance measurement

    PubMed Central

    van den Berg, Steven. A.; van Eldik, Sjoerd; Bhattacharya, Nandini

    2015-01-01

    Optical frequency combs have developed into powerful tools for distance metrology. In this paper we demonstrate absolute long distance measurement using a single femtosecond frequency comb laser as a multi-wavelength source. By applying a high-resolution spectrometer based on a virtually imaged phased array, the frequency comb modes are resolved spectrally to the level of an individual mode. Having the frequency comb stabilized against an atomic clock, thousands of accurately known wavelengths are available for interferometry. From the spectrally resolved output of a Michelson interferometer a distance is derived. The presented measurement method combines spectral interferometry, white light interferometry and multi-wavelength interferometry in a single scheme. Comparison with a fringe counting laser interferometer shows an agreement within <10−8 for a distance of 50 m. PMID:26419282

  18. Elastic Tape Improved Shoulder Joint Position Sense in Chronic Hemiparetic Subjects: A Randomized Sham-Controlled Crossover Study.

    PubMed

    Santos, Gabriela Lopes Dos; Souza, Matheus Bragança; Desloovere, Kaat; Russo, Thiago Luiz

    2017-01-01

    Elastic tape has been widely used in clinical practice in order to improve upper limb (UL) sensibility. However, there is little evidence that supports this type of intervention in stroke patients. To verify the effect of elastic tape, applied to the paretic shoulder, on joint position sense (JPS) during abduction and flexion in subjects with chronic hemiparesis compared to sham tape (non-elastic tape). Furthermore, to verify if this potential effect is correlated to shoulder subluxation measurements and sensorimotor impairment. A crossover and sham-controlled study was conducted with post-stroke patients who were randomly allocated into two groups: 1) those who received Sham Tape (ST) first and after one month they received Elastic Tape (ET); 2) those who received Elastic Tape (ET) first and after one month they received Sham Tape (ST). The JPS was evaluated using a dynamometer. The absolute error for shoulder abduction and flexion at 30° and 60° was calculated. Sensorimotor impairment was determined by Fugl-Meyer, and shoulder subluxation was measured using a caliper. Thirteen hemiparetic subjects (average time since stroke 75.23 months) participated in the study. At baseline (before interventions), the groups were not different for abduction at 30° (p = 0.805; p = 0.951), and 60° (p = 0.509; p = 0.799), or flexion at 30° (p = 0.872; p = 0.897) and 60° (p = 0.853; p = 0.970). For the ET group, differences between pre and post-elastic tape for abduction at 30° (p<0.010) and 60° (p<0.010), and flexion at 30° p<0.010) and 60° (p<0.010) were observed. For the ST group, differences were also observed between pre and post-elastic tape for abduction at 30° (p<0.010) and 60° (p<0.010), and flexion at 30° (p<0.010,) and 60° (p<0.010). Potential effects were only correlated with shoulder subluxation during abduction at 30° (p = 0.001, r = -0.92) and 60° (p = 0.020, r = -0.75). Elastic tape improved shoulder JPS of subjects with chronic hemiparesis

  19. Cryogenic colocalization microscopy for nanometer-distance measurements.

    PubMed

    Weisenburger, Siegfried; Jing, Bo; Hänni, Dominik; Reymond, Luc; Schuler, Benjamin; Renn, Alois; Sandoghdar, Vahid

    2014-03-17

    The main limiting factor in spatial resolution of localization microscopy is the number of detected photons. Recently we showed that cryogenic measurements improve the photostability of fluorophores, giving access to Angstrom precision in localization of single molecules. Here, we extend this method to colocalize two fluorophores attached to well-defined positions of a double-stranded DNA. By measuring the separations of the fluorophore pairs prepared at different design positions, we verify the feasibility of cryogenic distance measurement with sub-nanometer accuracy. We discuss the important challenges of our method as well as its potential for further improvement and various applications.

  20. Effects of Taping and Orthoses on Foot Biomechanics in Adults with Flat-Arched Feet.

    PubMed

    Bishop, Christopher; Arnold, John B; May, Thomas

    2016-04-01

    There is a paucity of evidence on the biomechanical effects of foot taping and foot orthoses in realistic conditions. This study aimed to determine the immediate effect and relationships between changes in multisegment foot biomechanics with foot taping and customized foot orthoses in adults with flat-arched feet. Multisegment foot biomechanics were measured in 18 adults with flat-arched feet (age 25.1 ± 2.8 yr; height 1.73 ± .13 m, body mass 70.3 ± 15.7 kg) during walking in four conditions in random order: neutral athletic shoe, neutral shoe with tape (low-Dye method and modified method) and neutral shoe with customized foot orthoses. In-shoe foot biomechanics were compared between conditions using a purpose developed foot model with three-dimensional kinematic analysis and inverse dynamics. Foot orthoses significantly delayed peak eversion compared to the neutral shoe (44% stance vs 39%, P = 0.002). Deformation across the midfoot and medial longitudinal arch was reduced with both the low-Dye taping (2.4°, P < 0.001) and modified taping technique (5.5°, P < 0.001). All interventions increased peak dorsiflexion of the first metatarsophalangeal joint (1.4°-3.2°, P < 0.001-0.023). Biomechanical responses to taping significantly predicted corresponding changes to foot orthoses (R2 = 0.08-0.52, P = 0.006 to <0.001). Foot orthoses more effectively altered timing of hindfoot motion whereas taping was superior in supporting the midfoot and medial longitudinal arch. The biomechanical response to taping was significantly related to the subsequent change observed with the use of foot orthoses.

  1. Kinesio Taping Fundamentals for the Equine Athlete.

    PubMed

    Molle, Sybille

    2016-04-01

    The Kinesio taping method was developed in Japan for use in humans in 1979. The use of complementary therapies is becoming common in equine athletes and the discovery of Kinesio taping potential brought it into the animal world. Kinesio taping can be used to treat a wide range of clinical conditions, from tendon injuries to neurologic disorders and from muscle contractures to postural insufficiencies. Its use in veterinary medicine is promising, but relies heavily on evidence-based clinical reports. Further scientific research is needed to fully understand the real effectiveness of application. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Effects of two different knee tape procedures on lower-limb kinematics and kinetics in recreational runners.

    PubMed

    Howe, A; Campbell, A; Ng, L; Hall, T; Hopper, D

    2015-08-01

    The purpose of this study was to compare the effects of Mulligan's tape (MT) and kinesio tape (KT) with no tape (NT) on hip and knee kinematics and kinetics during running. Twenty-nine female recreational runners performed a series of 'run-throughs' along a 10-m runway under the three taping conditions. Two force plates and a 14-camera Vicon motion analysis system (Oxford Metrics, Inc., Oxford, UK) captured kinematic and kinetic data for each dependent variable from ground contact to toe off. Comparisons of each dependent variable under three taping conditions were assessed through Statistical Package for the Social Sciences (SPSS; SPSS, Inc., Chicago, Illinois, USA; P-value < 0.01) using repeated measure analyses of variance. For each dependent variable with a P-value < 0.01, repeated measures with pairwise comparisons and Bonferroni adjustment were conducted to compare the three taping conditions. MT induced a significant reduction in anterior and posterior hip forces, knee flexion angular velocity, knee extensor moments, and hip flexion and extension moments compared with NT and KT (P = 0.001). There was no difference in hip or knee, kinematics or kinetics, between KT and NT (P = 1.000). MT appears to influence hip and knee biomechanics during running in an asymptomatic sample, whereas KT appeared to be biomechanically not different from NT. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. A comparison between using distance sensors for measuring the pantograph vertically movement

    NASA Astrophysics Data System (ADS)

    Rob, R.; Panoiu, C.; Rusu-Anghel, S.; Panoiu, M.

    2018-01-01

    In railway transportation the most important problem to solve consists in assuring the safety traffic of people and freight. In this scope some of the geometrical parameters regarding the contact line must be measured. One of this parameter is the pantograph vertically movement, so it must use distance sensors. Present paper studies the performance of two kinds of distance sensors, an ultrasonic distance sensor and an infrared sensor. The performances are studied from the point of view of error distance measurement and the possibility of using a real time acquisition system. The researches were made on a laboratory model for the pantograph realized at the scale 1:2.

  4. Method and apparatus for depositing a coating on a tape carrier

    DOEpatents

    Storer, Jonathan; Matias, Vladimir

    2010-06-15

    A system and method for depositing ceramic materials, such as nitrides and oxides, including high temperature superconducting oxides on a tape substrate. The system includes a tape support assembly that comprises a rotatable drum. The rotatable drum supports at least one tape substrate axially disposed on the surface of the drum during the deposition of metals on the tape and subsequent oxidation to form the ceramic materials. The drum is located within a stator having a slot that is axially aligned with the drum. A space exists between the drum and stator. The space is filled with a predetermined partial pressure of a reactive gas. The drum, stator, and space are heated to a predetermined temperature. To form the ceramic material on the tape substrate, the drum is first rotated to align the tape substrate with the slot, and at least one metal is deposited on the substrate. The drum then continues to rotate, bringing the tape substrate into the space, where the metal deposited on the tape substrate reacts with the reactive gas to form the ceramic material. In one embodiment, the tape support system also includes a pay-out/take-up system that co-rotates with the drum and provides a continuous length of tape substrate.

  5. Gd(III)-Gd(III) EPR distance measurements--the range of accessible distances and the impact of zero field splitting.

    PubMed

    Dalaloyan, Arina; Qi, Mian; Ruthstein, Sharon; Vega, Shimon; Godt, Adelheid; Feintuch, Akiva; Goldfarb, Daniella

    2015-07-28

    Gd(III) complexes have emerged as spin labels for distance determination in biomolecules through double-electron-electron resonance (DEER) measurements at high fields. For data analysis, the standard approach developed for a pair of weakly coupled spins with S = 1/2 was applied, ignoring the actual properties of Gd(III) ions, i.e. S = 7/2 and ZFS (zero field splitting) ≠ 0. The present study reports on a careful investigation on the consequences of this approach, together with the range of distances accessible by DEER with Gd(III) complexes as spin labels. The experiments were performed on a series of specifically designed and synthesized Gd-rulers (Gd-PyMTA-spacer-Gd-PyMTA) covering Gd-Gd distances of 2-8 nm. These were dissolved in D2O-glycerol-d8 (0.03-0.10 mM solutions) which is the solvent used for the corresponding experiments on biomolecules. Q- and W-band DEER measurements, followed by data analysis using the standard data analysis approach, used for S = 1/2 pairs gave the distance-distribution curves, of which the absolute maxima agreed very well with the expected distances. However, in the case of the short distances of 2.1 and 2.9 nm, the distance distributions revealed additional peaks. These are a consequence of neglecting the pseudo-secular term in the dipolar Hamiltonian during the data analysis, as is outlined in a theoretical treatment. At distances of 3.4 nm and above, disregarding the pseudo-secular term leads to a broadening of a maximum of 0.4 nm of the distance-distribution curves at half height. Overall, the distances of up to 8.3 nm were determined, and the long evolution time of 16 μs at 10 K indicates that a distance of up to 9.4 nm can be accessed. A large distribution of the ZFS parameter, D, as is found for most Gd(III) complexes in a frozen solution, is crucial for the application of Gd(III) complexes as spin labels for distance determination via Gd(III)-Gd(III) DEER, especially for short distances. The larger ZFS of Gd-PyMTA, in

  6. Numerical and Experimental Investigation of the Electromechanical Behavior of REBCO Tapes

    NASA Astrophysics Data System (ADS)

    Allen, N. C.; Chiesa, L.; Takayasu, M.

    2015-12-01

    To fully characterize the electromechanical behavior of a Twisted Stacked-Tape Cable (TSTC) it is important to understand the performance of the individual REBCO tapes under various loading conditions. Numerical modeling and experimentation have been used to investigate the electromechanical characteristics of two commercially available REBCO tapes (SuperPower and SuNAM). Tension and combined tension-torsion experiments on single tapes have been continued, from prior preliminary studies, to characterize their critical current behavior and mechanical strength. Additionally, structural finite element analysis was performed on single tapes under tension and combined tension-torsion to investigate the strain dependence of the critical current. The numerical results were compared to the experimental findings for validation. The SuNAM experimental data matched the numerical model very well while the SuperPower tape experienced degradation at lower stress and strain than predicted in the model. The Superpower tape also displayed greater variability in critical current between different samples as compared with the SuNAM tape.

  7. Star Catalogs on Punched Cards and Magnetic Tape

    NASA Technical Reports Server (NTRS)

    Berbert, J. H.

    1961-01-01

    In connection with the calibration of the Minitrack satellite tracking stations, the Goddard Space Flight Center has had the contents of a number of star catalogs put on punched cards and magnetic tape. This report discusses the plate data reduction procedures, briefly describes the information on the punched cards and magnetic tape, and calls attention to other applications of the card and tape star catalogs. The Goddard Space Flight Center has offered to prepare duplicate catalogs for qualified organizations.

  8. Index of Refraction Measurements Using a Laser Distance Meter

    ERIC Educational Resources Information Center

    Ochoa, Romulo; Fiorillo, Richard; Ochoa, Cris

    2014-01-01

    We present a simple method to determine the refractive indices of transparent media using a laser distance meter. Indices of refraction have been obtained by measuring the speed of light in materials. Some speed of light techniques use time-of-flight measurements in which pulses are emitted by lasers and the time interval is measured for the pulse…

  9. The Effects of Rigid Scapular Taping on the Subacromial Space in Athletes With and Without Rotator Cuff Tendinopathy: A Randomized-Controlled Study.

    PubMed

    Leong, Hio Teng; Fu, Siu Ngor

    2018-02-21

    Reduction of the subacromial space (SAS) during arm elevation may contribute to rotator cuff tendinopathy. The effects of scapular taping on the SAS in athletes with and without RC tendinopathy is unknown. To investigate the immediate effects of scapular taping on the SAS in athletes with and without RC tendinopathy. Randomized-controlled with repeated measures. University laboratory. Forty-three male volleyball players (17 asymptomatic and 26 with RC tendinopathy, mean age = 22.9±3.5 years) participated in the study. Three scapular taping protocols - no taping (control), taping with tension (therapeutic taping) and taping without tension (sham taping). Ultrasound measurements of the SAS with the arm at 0° and 60° of shoulder abduction, and the change in the SAS between 0° and 60° of shoulder abduction (SAS 0°-60° ) were calculated. Athletes with RC tendinopathy demonstrated larger SAS with therapeutic taping at 60° of shoulder abduction (6.9±1.9 mm vs. 5.8±1.7 mm, mean difference = 1.1 mm, 95% CI = -1.80 - -0.39, p=0.002) when compared to the no taping condition. The tendinopathy group also showed less reduction in the SAS with therapeutic taping during SAS 0°-60° (2.0±1.4 mm vs. 2.8±1.4 mm, p=0.023) when compared to the no taping condition. When tape was applied to the scapula in asymptomatic athletes, our results showed a relatively small increase in the SAS with therapeutic taping during arm resting at 0° of abduction when compared to the no taping condition (8.7±0.9 mm vs. 8.3±0.8 mm, mean difference = 0.4 mm, 95% CI = -0.71 - -0.11, p=0.008). Athletes with RC tendinopathy demonstrated less reduction of the SAS with rigid scapular taping during early arm abduction. Such observation was not evidenced in asymptomatic athletes.

  10. Design study for multi-channel tape recorder system, volume 2

    NASA Technical Reports Server (NTRS)

    1972-01-01

    Skew test data are presented on a tape recorder transport with a double capstan drive for a 100 KHz tone recorded on five tracks simultaneously. Phase detectors were used to measure the skew when the center channel was the 100 KHz reference.

  11. New hesitation-based distance and similarity measures on intuitionistic fuzzy sets and their applications

    NASA Astrophysics Data System (ADS)

    Kang, Yun; Wu, Shunxiang; Cao, Da; Weng, Wei

    2018-03-01

    In this paper, we present new definitions on distance and similarity measures between intuitionistic fuzzy sets (IFSs) by combining with hesitation degree. First, we discuss the limitations in traditional distance and similarity measures, which are caused by the neglect of hesitation degree's influence. Even though a vector-valued similarity measure was proposed, which has two components indicating similarity and hesitation aspects, it still cannot perform well in practical applications because hesitation works only when the values of similarity measures are equal. In order to overcome the limitations, we propose new definitions on hesitation, distance and similarity measures, and research some theorems which satisfy the requirements of the proposed definitions. Meanwhile, we investigate the relationships among hesitation, distance, similarity and entropy of IFSs to verify the consistency of our work and previous research. Finally, we analyse and discuss the advantages and disadvantages of the proposed similarity measure in detail, and then we apply the proposed measures (dH and SH) to deal with pattern recognition problems, and demonstrate that they outperform state-of-the-art distance and similarity measures.

  12. Ankle Ranges of Motion During Extended Activity Periods While Taped and Braced

    PubMed Central

    Paris, David L.; Kokkaliaris, Jimmy; Vardaxis, Vassilios

    1995-01-01

    Tape has traditionally been used to support the ankle during activity. More recently, commercial ankle braces have been worn as an alternative. The cumulative information on the effects of taped versus braced ankle support or interbrace comparisons is inconclusive. With few exceptions, ankle brace studies have collected data soon after support conditions were administered. Plantar-dorsiflexion and inversion-eversion ranges of motion (ROM) of 30 subjects were compared under conditions of unsupported, nonelastic adhesivetaped, and Swede-O and Sub Talar Support-braced ankles. We recorded measurements before activity and after periods of 15, 30, 45, and 60 minutes of selected activity on a motorized treadmill. All support conditions significantly reduced preactivity ROM in all directions compared to unsupported ankles. Results showed that the ankle significantly increased in plantarflexion ROM 15 minutes after the initiation of activity with tape or the SubTalar Support-brace, and after 30 minutes with the Swede-O brace. Tape showed further significant increases in plantarflexion ROM after 15-minute intervals of 30, 45, and 60 minutes of activity. All three support conditions had increased significantly in inversion ROM by 15 minutes of activity. The SubTalar Support brace showed a further significant inversion ROM increase between 15 and 30 minutes postactivity. We conclude that the Swede-O and SubTalar Support braces and tape offer significant preactivity ankle support in all four directions of movement. We also conclude that both braces offer longer postactivity support than tape. In inversion ROM and plantarflexion ROM, actions prevalent in ankle sprains, the Swede-O brace retained support longer than the SubTalar Support brace. ImagesFig 1.Fig 2.Fig 3. PMID:16558340

  13. Experiments and FE modeling of stress-strain state in ReBCO tape under tensile, torsional and transverse load

    NASA Astrophysics Data System (ADS)

    Ilin, K.; Yagotintsev, K. A.; Zhou, C.; Gao, P.; Kosse, J.; Otten, S. J.; Wessel, W. A. J.; Haugan, T. J.; van der Laan, D. C.; Nijhuis, A.

    2015-05-01

    For high current superconductors in high magnet fields with currents in the order of 50 kA, single ReBCO coated conductors must be assembled in a cable. The geometry of such a cable is mostly such that combined torsion, axial and transverse loading states are anticipated in the tapes and tape joints. The resulting strain distribution, caused by different thermal contraction and electromagnetic forces, will affect the critical current of the tapes. Tape performance when subjected to torsion, tensile and transverse loading is the key to understanding limitations for the composite cable performance. The individual tape material components can be deformed, not only elastically but also plastically under these loads. A set of experimental setups, as well as a convenient and accurate method of stress-strain state modeling based on the finite element method have been developed. Systematic measurements on single ReBCO tapes are carried out combining axial tension and torsion as well as transverse loading. Then the behavior of a single tape subjected to the various applied loads is simulated in the model. This paper presents the results of experimental tests and detailed FE modeling of the 3D stress-strain state in a single ReBCO tape under different loads, taking into account the temperature dependence and the elastic-plastic properties of the tape materials, starting from the initial tape processing conditions during its manufacture up to magnet operating conditions. Furthermore a comparison of the simulations with experiments is presented with special attention for the critical force, the threshold where the tape performance becomes irreversibly degraded. We verified the influence of tape surface profile non-uniformity and copper stabilizer thickness on the critical force. The FE models appear to describe the tape experiments adequately and can thus be used as a solid basis for optimization of various cabling concepts.

  14. Measurement of "g" Using a Flashing LED

    ERIC Educational Resources Information Center

    Terzella, T.; Sundermier, J.; Sinacore, J.; Owen, C.; Takai, H.

    2008-01-01

    In one of the classic free-fall experiments, a small mass is attached to a strip of paper tape and both are allowed to fall through a spark timer, where sparks are generated at regular time intervals. Students analyze marks (dots) left on the tape by the timer, thereby generating distance-versus-time data, which they analyze to extract the…

  15. Non-contact inline monitoring of thermoplastic CFRP tape quality using air-coupled ultrasound

    NASA Astrophysics Data System (ADS)

    Essig, W.; Fey, P.; Meiler, S.; Kreutzbruck, M.

    2017-02-01

    Beginning with the aerospace industry, fiber reinforced plastics have spread towards many applications such as automotive, civil engineering as well as sports and leisure articles. Their superior strength and stiffness to mass ratio made them the number one material for achieving high performance. Especially continuous fiber reinforced plastics allow for the construction of structures which are custom tailored to their mechanical loads by adjusting the paths of the fibers to the loading direction. The two main constituents of CFRP are carbon fibers and matrix. Two possibilities for matrix material exist: thermosetting and thermoplastic matrix. While thermosetting matrix may yield better properties with respect to thermal loads, thermoplasticity opens a wide range of applications due to weldability, shapeability, and compatibility to e.g. injection molded thermoplastic materials. Thin (0.1 mm) thermoplastic continuous fiber CFRP tapes with a width of 100 mm were examined using air-coupled ultrasound. Transducers were arranged in reflection as well as transmission setup. By slanted incidence of the ultrasound on the tape surface, guided waves were excited in the material in fiber direction and perpendicular to the fiber direction. Artificial defects - fiber cuts, matrix cuts, circular holes, low velocity impacts from tool drop, and sharp bends - were produced. Experiments on a stationary tape showed good detectability of all artificial defects by guided waves. Also the effects of variation in material properties, fiber volume content and fiber matrix adhesion being the most relevant, on guided wave propagation were examined, to allow for quality assessment. Guided wave measurements were supported by destructive analysis. Also an apparatus containing one endless loop of CFRP tape was constructed and built to simulate inline testing of CFRP tapes, as it would be employed in a CFRP tape production environment or at a CFRP tape processing facility. The influences of tape

  16. Short-Term Effects of Kinesio Taping in Women with Pregnancy-Related Low Back Pain: A Randomized Controlled Clinical Trial.

    PubMed

    Kaplan, Şeyhmus; Alpayci, Mahmut; Karaman, Erbil; Çetin, Orkun; Özkan, Yasemin; İlter, Server; Şah, Volkan; Şahin, Hanım Güler

    2016-04-18

    BACKGROUND Pregnancy-related low back pain is a common condition during pregnancy. Kinesio tape is a drug-free elastic therapeutic tape used for treating various musculoskeletal problems. The aim of this study was to investigate the short-term effects of lumbar Kinesio taping on pain intensity and disability in women with pregnancy-related low back pain. MATERIAL AND METHODS A total of 65 patients with pregnancy-related low back pain were randomly allocated into either Kinesio taping (n=33) or control (n=32) groups. The intervention group was treated with paracetamol plus Kinesio taping, while the control group received only paracetamol. Kinesio taping was applied in the lumbar flexion position, and four I-shaped bands were used. Two bands were attached horizontally, with space correction technique. The remaining 2 bands, 1 on each side of the lumbar spine, were placed vertically, with inhibition technique. Low back pain intensity was measured on a 10-cm visual analogue scale (VAS), and the Roland-Morris Disability Questionnaire (RMDQ) was used for evaluation of disability. RESULTS Pain intensity and RMDQ scores improved significantly in both groups at 5 days compared with baseline. Considering the degree of treatment effect (the change from baseline to day 5), the Kinesio taping group was significantly superior than the control group in all outcome measures (for all, P<0.001). CONCLUSIONS The results of this study indicate that Kinesio taping can be used as a complementary treatment method to achieve effective control of pregnancy-related low back pain.

  17. Analytical investigation in bending characteristic of twisted stacked-tape cable conductor

    NASA Astrophysics Data System (ADS)

    Takayasu, Makoto; Chiesa, Luisa

    2015-12-01

    An analytical model to evaluate bending strains of a twisted stack-tape cable (TSTC) conductor has been developed. Through a comparison with experimental results obtained for a soldered 32-tape YBCO TSTC conductor, it has been found that a Perfect-Slip Model (PSM) taking into account the slipping between tapes in a stacked-tape cable during bending gives much better estimation of the bending performance compared to a No-Slip Model (NSM). In the PSM case the tapes can slip so that the internal longitudinal axial strain can be released. The longitudinal strains of compression and tension regions along the tape are balanced in one twist-pitch and cancel out evenly in a long cable. Therefore, in a cable the strains due to bending can be minimized. This is an important advantage of a TSTC conductor. The effect of the cable diameter size on the bending strain is also expected to be minor, and all tapes composing a TSTC conductor have the same strain response under bending, therefore the cable critical current can be characterized from a single tape behaviour.

  18. Cassette Tape Catalog: 1980/1981 Unabridged Supplement.

    ERIC Educational Resources Information Center

    American Child Care Services, Hampton, VA.

    This unabridged supplement to the Child Care Information Center's tape cassette catalog contains a listing of all recordings made in calendar years 1980 and 1981. This document plus "The Revised 1976 Cassette Tape Catalog,""The 1977 Addendum," and "The 1978/1979 Unabridged Supplement" together provide a complete listing of the 1,776 tape…

  19. Comparison of efficiency of distance measurement methodologies in mango (Mangifera indica) progenies based on physicochemical descriptors.

    PubMed

    Alves, E O S; Cerqueira-Silva, C B M; Souza, A M; Santos, C A F; Lima Neto, F P; Corrêa, R X

    2012-03-14

    We investigated seven distance measures in a set of observations of physicochemical variables of mango (Mangifera indica) submitted to multivariate analyses (distance, projection and grouping). To estimate the distance measurements, five mango progeny (total of 25 genotypes) were analyzed, using six fruit physicochemical descriptors (fruit weight, equatorial diameter, longitudinal diameter, total soluble solids in °Brix, total titratable acidity, and pH). The distance measurements were compared by the Spearman correlation test, projection in two-dimensional space and grouping efficiency. The Spearman correlation coefficients between the seven distance measurements were, except for the Mahalanobis' generalized distance (0.41 ≤ rs ≤ 0.63), high and significant (rs ≥ 0.91; P < 0.001). Regardless of the origin of the distance matrix, the unweighted pair group method with arithmetic mean grouping method proved to be the most adequate. The various distance measurements and grouping methods gave different values for distortion (-116.5 ≤ D ≤ 74.5), cophenetic correlation (0.26 ≤ rc ≤ 0.76) and stress (-1.9 ≤ S ≤ 58.9). Choice of distance measurement and analysis methods influence the.

  20. Measurement of Transcranial Distance During Head-Down Tilt Using Ultrasound

    NASA Technical Reports Server (NTRS)

    Torikoshi, Shigeyo; Ballard, R. E.; Watenpaugh, D. E.; Murthy, G.; Bowley, S.; Yost, W. T.; Hargens, Alan R.

    1995-01-01

    Exposure to microgravity probably elevates blood pressure and flow in the head which may increase intracranial volume (ICV) and pressure (ICP). Due to the slightly compliant nature of the cranium, any increase of ICP will increase ICV and transcranial distance. We used a noninvasive ultrasound technique to measure transcranial distance (frontal to occipital) during head-down tilt. Seven subjects (ages 26-53) underwent the following tilt angles: 90 deg. upright, 30 deg., 0 deg., -6 deg., -10 deg., -6 deg., 0 deg., 30 deg., and 90 deg. Each angle was maintained for 1 min. Ultrasound wave frequency was collected continuously and transcranial distance was calculated (Delta(x) = x(Delta)f/f, where x is path length and f is frequency of the wave) for each tilt angle. Frequency decreased from 503.687 kHz (90 deg. upright) to 502.619 kHz (-10 deg.). These frequencies translated to an increased transcranial distance of 0.403 mm. Although our data suggest a significant increase in transcranial distance during head-down tilt, this apparent increase may result, in part, from head-down tilt-induced subcutaneous edema or cutaneous blood volume elevation. In three subjects, when the above protocol was repeated with an ace bandage wrapped around the head to minimize such edema, the increased transcranial distance from 90 deg. to -10 deg. was reduced by 0.174 mm. Further development of the technique to quantify bone-to-bone expansion unconfounded by cutaneous fluid is necessary. Therefore, this ultrasound technique may provide measurements of changes in cranial dimensions during microgravity.

  1. High-Tensile Strength Tape Versus High-Tensile Strength Suture: A Biomechanical Study.

    PubMed

    Gnandt, Ryan J; Smith, Jennifer L; Nguyen-Ta, Kim; McDonald, Lucas; LeClere, Lance E

    2016-02-01

    To determine which suture design, high-tensile strength tape or high-tensile strength suture, performed better at securing human tissue across 4 selected suture techniques commonly used in tendinous repair, by comparing the total load at failure measured during a fixed-rate longitudinal single load to failure using a biomechanical testing machine. Matched sets of tendon specimens with bony attachments were dissected from 15 human cadaveric lower extremities in a manner allowing for direct comparison testing. With the use of selected techniques (simple Mason-Allen in the patellar tendon specimens, whip stitch in the quadriceps tendon specimens, and Krackow stitch in the Achilles tendon specimens), 1 sample of each set was sutured with a 2-mm braided, nonabsorbable, high-tensile strength tape and the other with a No. 2 braided, nonabsorbable, high-tensile strength suture. A total of 120 specimens were tested. Each model was loaded to failure at a fixed longitudinal traction rate of 100 mm/min. The maximum load and failure method were recorded. In the whip stitch and the Krackow-stitch models, the high-tensile strength tape had a significantly greater mean load at failure with a difference of 181 N (P = .001) and 94 N (P = .015) respectively. No significant difference was found in the Mason-Allen and simple stitch models. Pull-through remained the most common method of failure at an overall rate of 56.7% (suture = 55%; tape = 58.3%). In biomechanical testing during a single load to failure, high-tensile strength tape performs more favorably than high-tensile strength suture, with a greater mean load to failure, in both the whip- and Krackow-stitch models. Although suture pull-through remains the most common method of failure, high-tensile strength tape requires a significantly greater load to pull-through in a whip-stitch and Krakow-stitch model. The biomechanical data obtained in the current study indicates that high-tensile strength tape may provide better repair

  2. DISTANCES TO DARK CLOUDS: COMPARING EXTINCTION DISTANCES TO MASER PARALLAX DISTANCES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Foster, Jonathan B.; Jackson, James M.; Stead, Joseph J.

    We test two different methods of using near-infrared extinction to estimate distances to dark clouds in the first quadrant of the Galaxy using large near-infrared (Two Micron All Sky Survey and UKIRT Infrared Deep Sky Survey) surveys. Very long baseline interferometry parallax measurements of masers around massive young stars provide the most direct and bias-free measurement of the distance to these dark clouds. We compare the extinction distance estimates to these maser parallax distances. We also compare these distances to kinematic distances, including recent re-calibrations of the Galactic rotation curve. The extinction distance methods agree with the maser parallax distancesmore » (within the errors) between 66% and 100% of the time (depending on method and input survey) and between 85% and 100% of the time outside of the crowded Galactic center. Although the sample size is small, extinction distance methods reproduce maser parallax distances better than kinematic distances; furthermore, extinction distance methods do not suffer from the kinematic distance ambiguity. This validation gives us confidence that these extinction methods may be extended to additional dark clouds where maser parallaxes are not available.« less

  3. Simulation and analysis of tape spring for deployed space structures

    NASA Astrophysics Data System (ADS)

    Chang, Wei; Cao, DongJing; Lian, MinLong

    2018-03-01

    The tape spring belongs to the configuration of ringent cylinder shell, and the mechanical properties of the structure are significantly affected by the change of geometrical parameters. There are few studies on the influence of geometrical parameters on the mechanical properties of the tape spring. The bending process of the single tape spring was simulated based on simulation software. The variations of critical moment, unfolding moment, and maximum strain energy in the bending process were investigated, and the effects of different radius angles of section and thickness and length on driving capability of the simple tape spring was studied by using these parameters. Results show that the driving capability and resisting disturbance capacity grow with the increase of radius angle of section in the bending process of the single tape spring. On the other hand, these capabilities decrease with increasing length of the single tape spring. In the end, the driving capability and resisting disturbance capacity grow with the increase of thickness in the bending process of the single tape spring. The research has a certain reference value for improving the kinematic accuracy and reliability of deployable structures.

  4. Study on the measuring distance for blood glucose infrared spectral measuring by Monte Carlo simulation

    NASA Astrophysics Data System (ADS)

    Li, Xiang

    2016-10-01

    Blood glucose monitoring is of great importance for controlling diabetes procedure and preventing the complications. At present, the clinical blood glucose concentration measurement is invasive and could be replaced by noninvasive spectroscopy analytical techniques. Among various parameters of optical fiber probe used in spectrum measuring, the measurement distance is the key one. The Monte Carlo technique is a flexible method for simulating light propagation in tissue. The simulation is based on the random walks that photons make as they travel through tissue, which are chosen by statistically sampling the probability distributions for step size and angular deflection per scattering event. The traditional method for determine the optimal distance between transmitting fiber and detector is using Monte Carlo simulation to find out the point where most photons come out. But there is a problem. In the epidermal layer there is no artery, vein or capillary vessel. Thus, when photons propagate and interactive with tissue in epidermal layer, no information is given to the photons. A new criterion is proposed to determine the optimal distance, which is named effective path length in this paper. The path length of each photons travelling in dermis is recorded when running Monte-Carlo simulation, which is the effective path length defined above. The sum of effective path length of every photon at each point is calculated. The detector should be place on the point which has most effective path length. Then the optimal measuring distance between transmitting fiber and detector is determined.

  5. Measuring Distance Learning Performance with Data Envelopment Analysis

    ERIC Educational Resources Information Center

    Xiaoming, Yang; Shieh, Chich-Jen; Wu, Wu-Chung

    2014-01-01

    In the modern society with changeable information technology learning and applications, students could acquire information application knowledge, which is not worse than those taught by teachers in classrooms, through the Internet, distance conference, and e-learning. Traditional instruction therefore is facing great challenges. When measuring the…

  6. An analysis of the surface-normal coupling efficiency of a metal grating coupler embedded in a Scotch tape optical waveguide

    NASA Astrophysics Data System (ADS)

    Barrios, Carlos Angulo; Canalejas-Tejero, Víctor

    2017-01-01

    The coupling efficiency at normal incidence of recently demonstrated aluminum grating couplers integrated in flexible Scotch tape waveguides has been analyzed theoretically and experimentally. Finite difference time domain (FDTD) and rigorously coupled wave analysis (RCWA) methods have been used to optimize the dimensions (duty cycle and metal thickness) of Scotch tape-embedded 1D Al gratings for maximum coupling at 635 nm wavelength. Good dimension and tape refractive index tolerances are predicted. FDTD simulations reveal the incident beam width and impinging position (alignment) values that avoid rediffraction and thus maximize the coupling efficiency. A 1D Al diffraction grating integrated into a Scotch tape optical waveguide has been fabricated and characterized. The fabrication process, based on pattern transfer, has been optimized to allow complete Al grating transfer onto the Scotch tape waveguide. A maximum coupling efficiency of 20% for TM-polarized normal incidence has been measured, which is in good agreement with the theoretical predictions. The measured coupling efficiency is further increased up to 28% for TM polarization under oblique incidence. Temperature dependence measurements have been also achieved and related to the simulations results and fabrication procedure.

  7. Does taping in addition to physiotherapy improve the outcomes in subacromial impingement syndrome? A systematic review.

    PubMed

    Saracoglu, Ismail; Emuk, Yusuf; Taspinar, Ferruh

    2018-04-01

    Taping is used with or without other interventions for many purposes, especially to manage pain and improve functional activity in patients with shoulder pain. The aim of this review was to determine whether any taping technique in addition to physiotherapy care is more effective than physiotherapy care alone in patients with shoulder impingement syndrome. A systematic search of Cochrane Database of Systematic Review, MEDLINE (EBSCO), Physiotherapy Evidence Database (PEDro), CINAHL (EBSCO), PUBMED, AMED, EMBASE (OVID), The Kinesio Kinesio® Taping Method, Kinesio® Tex Tape UK and International websites ( www.kinesiotaping.co.uk ; www.kinesiotaping.com ) was conducted to June 2015. The outcome measures were pain, disability, range of motion and muscle strength. As data were not suitable for meta-analysis, narrative synthesis were applied. Three randomized controlled trials and one controlled trial (135 patients) were included. The results were conflicting and weak on the effectiveness of taping as an adjunct therapy for improvement of pain, disability, range of motion and muscle strength. Clinical taping in addition to physiotherapy interventions (e.g. exercise, electrotherapy, and manual therapy) might be an optional modality for managing patients with shoulder impingement syndrome, especially for the initial stage of the treatment; however, we need further robust, placebo controlled and consistent studies to prove whether it is more effective than physiotherapy interventions without taping.

  8. Dry Process for Making Polyimide/ Carbon-and-Boron-Fiber Tape

    NASA Technical Reports Server (NTRS)

    Belvin, Harry L.; Cano, Roberto J.; Johnston, Norman J.; Marchello, Joseph M.

    2003-01-01

    A dry process has been invented as an improved means of manufacturing composite prepreg tapes that consist of high-temperature thermoplastic polyimide resin matrices reinforced with carbon and boron fibers. Such tapes are used (especially in the aircraft industry) to fabricate strong, lightweight composite-material structural components. The inclusion of boron fibers results in compression strengths greater than can be achieved by use of carbon fibers alone. The present dry process is intended to enable the manufacture of prepreg tapes (1) that contain little or no solvent; (2) that have the desired dimensions, fiber areal weight, and resin content; and (3) in which all of the fibers are adequately wetted by resin and the boron fibers are fully encapsulated and evenly dispersed. Prepreg tapes must have these properties to be useable in the manufacture of high-quality composites by automated tape placement. The elimination of solvent and the use of automated tape placement would reduce the overall costs of manufacturing.

  9. Time delay and distance measurement

    NASA Technical Reports Server (NTRS)

    Abshire, James B. (Inventor); Sun, Xiaoli (Inventor)

    2011-01-01

    A method for measuring time delay and distance may include providing an electromagnetic radiation carrier frequency and modulating one or more of amplitude, phase, frequency, polarization, and pointing angle of the carrier frequency with a return to zero (RZ) pseudo random noise (PN) code. The RZ PN code may have a constant bit period and a pulse duration that is less than the bit period. A receiver may detect the electromagnetic radiation and calculate the scattering profile versus time (or range) by computing a cross correlation function between the recorded received signal and a three-state RZ PN code kernel in the receiver. The method also may be used for pulse delay time (i.e., PPM) communications.

  10. LGSOWG CCT format CCB document: The standard CCT family of tape formats

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The tape format standardization approach recommended by the committee on CCT standardization is described and defined. All rules and conventions required to employ the superstructure approach to the CCT family of tape formats are presented for users of remote sensing data and producer of user tapes and the superstructure records are specified. The standard for future tape format design is presented as a guide to designing data records of a particular tape format. An example is provided showing how to incorporate the superstructure into an already established tape format.

  11. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, E.B.; Muller, A.C.

    1983-07-15

    The present invention is a cable which, although constructed from inexpensive polyolefin tapes and using typical impregnating oils, furnishes high voltage capability up to 765 kV, and has such excellent dielectric characteristics and heat transfer properties that it is capable of operation at capacities equal to or higher than presently available cables at a given voltage. This is accomplished by using polyethylene, polybutene or polypropylene insulating tape which has been specially processed to attain properties which are not generally found in these materials, but are required for their use in impregnated electrical cables. Chief among these properties is compatibility with impregnating oil.

  12. Superconducting flat tape cable magnet

    DOEpatents

    Takayasu, Makoto

    2015-08-11

    A method for winding a coil magnet with the stacked tape cables, and a coil so wound. The winding process is controlled and various shape coils can be wound by twisting about the longitudinal axis of the cable and bending following the easy bend direction during winding, so that sharp local bending can be obtained by adjusting the twist pitch. Stack-tape cable is twisted while being wound, instead of being twisted in a straight configuration and then wound. In certain embodiments, the straight length should be half of the cable twist-pitch or a multiple of it.

  13. Transparent layered YAG ceramics with structured Yb doping produced via tape casting

    NASA Astrophysics Data System (ADS)

    Hostaša, Jan; Piancastelli, Andreana; Toci, Guido; Vannini, Matteo; Biasini, Valentina

    2017-03-01

    The flexibility of the ceramic production process, in particular in terms of shaping and spatial control of distribution of active ions, is one of the strong points in favor of transparent ceramics. In high power lasers in particular, where thermal management is a critical issue, the finely controlled design of spatial distribution of the doping ions within the laser gain media can reduce undesired thermally induced effects and large temperature gradients, and thus enhance the efficiency and laser beam quality especially under increased thermal load. In the present work transparent structured YAG ceramics with Yb doping were produced by tape casting followed by thermal compression of assembled tapes and sintered under high vacuum. The thermal compression of variously doped tape cast layers is a very promising method because it allows a high precision and good control over dopant distribution in the sintered material. After sintering, the distribution of Yb across the layers was characterized by SEM-EDX and the thickness of Yb diffusion zones between the layers with different Yb content was measured. Optical homogeneity was assessed by means of optical transmittance mapping of the samples and by 2D scanning of laser output. The effect of structured dopant distribution on laser performance was measured in quasi-CW and CW regime with different duty factors. Slope efficiency values higher than 50% were measured both in quasi-CW and in CW lasing conditions. The results are in good agreement with previously calculated predictions, confirming the beneficial effect of structured doping on laser performances and enlightening the impact of the residual scattering losses. Compared to other processing methods, such as the pressing of granulated powders, tape casting followed by thermal compression leads to straight and narrow interfaces between layers with different composition and allows to build structures composed of extremely thin layers with defined dopant content.

  14. Properties of pressure-sensitive adhesive tapes with soft adhesives to human skin and their mechanism.

    PubMed

    Tokumura, Fumio; Homma, Takeyasu; Tomiya, Toshiki; Kobayashi, Yuko; Matsuda, Tetsuaki

    2007-05-01

    The use of soft adhesives in the manufacture of pressure-sensitive adhesive tapes has recently increased. The dermal peeling force of adhesive tapes with soft adhesives was studied. Four kinds of adhesive tapes with adhesives of different softness were made, by adding varying amounts of isopropyl myristate as a softener. The tapes were applied on the flexor side of the forearm of six healthy male volunteers. The dermal peeling force, the amount of stripped corneocytes, the level of pain when the tapes were removed and the degree of penetration of adhesives into the sulcus cutis (skin furrows) were evaluated at 1 and 24 h after application of the tapes. Furthermore, a skin model panel (a sulcus cutis and crista cutis model panel) and a crista cutis model panel were constructed from a general stainless-steel panel, and the peeling force of the tapes against the model panels was measured. As the softness of adhesives increased, the peeling force against a general stainless-steel panel with a flat surface decreased, although the peeling force against human skin did not significantly change. The amount of stripped corneocytes on the removed tapes and the level of pain when the tapes were removed decreased with the increase in softness of the adhesives. These results suggest that adhesive tapes with soft adhesives that contain isopropyl myristate as a softener are suitable for the skin. Furthermore, the degree of penetration of adhesive into the sulcus cutis increased as the softness of adhesives increased. Upon evaluation of the peeling force against the model panels, as the softness of adhesives increased, there was a slight decrease in the peeling force against the skin model panel, while there was a remarkable decrease in the peeling force against the crista cutis model panel. These results suggest that the lack of change in the dermal peeling force as the softness of adhesives increased was caused by penetration of soft adhesive into the sulcus cutis, and that the

  15. A Test of the Validity of Projective and Quasi-Projective Measures of Interpersonal Distance.

    ERIC Educational Resources Information Center

    Jones, Stanley E.; Aiello, John R.

    1979-01-01

    Discusses research supporting the conclusion that projective and quasi-projective measures of interpersonal distance do not measure the same phenomena as interactional measures. It is possible that they are more indicative of psychological rather than physical distance. (JMF)

  16. 75 FR 14628 - Pressure Sensitive Plastic Tape From Italy; Determination

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-26

    ... Plastic Tape From Italy; Determination On the basis of the record \\1\\ developed in the subject five-year... pressure sensitive plastic tape from Italy would be likely to lead to continuation or recurrence of... Publication 4128 (March 2010), entitled Pressure Sensitive Plastic Tape from Italy: Investigation No. AA1921...

  17. Testing of a 1.25-m HTS Cable Made from YBCO Tapes

    NASA Astrophysics Data System (ADS)

    Gouge, M. J.; Lue, J. W.; Demko, J. A.; Duckworth, R. C.; Fisher, P. W.; Daumling, M.; Lindsay, D. T.; Roden, M. L.; Tolbert, J. C.

    2004-06-01

    Ultera and Oak Ridge National Laboratory (ORNL) have jointly designed, built, and tested a 1.25-m-long, prototype high-temperature superconducting (HTS) power cable made from 1-cm-wide, second-generation YBa2Cu3Ox (YBCO)-coated conductor tapes. Electrical tests of this cable were performed in boiling liquid nitrogen at 77 K. DC testing of the 1.25-m cable included determination of the V-I curve, with a critical current of 4200 A. This was consistent with the properties of the 24 individual YBCO tapes. AC testing of the cable was conducted at currents up to 2500 Arms. The ac losses were measured calorimetrically by measuring the response of a calibrated temperature sensor placed on the former and electrically by use of a Rogowski coil with a lock-in amplifier. AC losses of about 2 W/m were measured at a cable ac current of 2000 Arms. Overcurrent testing was conducted at peak current values up to 12 kA for pulse lengths of 0.1-0.2 s. The cable temperature increased to 105 K for a 12 kA, 0.2 s overcurrent pulse, and the cable showed no degradation after the sequence of overcurrent testing. This commercial-grade HTS cable demonstrated the feasibility of second-generation YBCO tapes in an ac cable application.

  18. STS-88 Mission Highlights Resources Tape. Tape B

    NASA Technical Reports Server (NTRS)

    1999-01-01

    The STS-88 flight crew, Commander Robert D. Cabana, Pilot Frederick W. Sturckow, and Mission Specialists Nancy J. Currie, James H. Newman, Jerry L. Ross, and Sergei Krikalev present a video overview of their space flight. Tape two of three includes the installation of an S-Band to help monitor the UNITY Connecting Module, the opening of UNITY's hatch, the opening of the main compartment hatch to ZARYA Control Module, and the repair of the inflight maintenance system.

  19. Effects of scapular taping on the activity onset of scapular muscles and the scapular kinematics in volleyball players with rotator cuff tendinopathy.

    PubMed

    Leong, Hio Teng; Ng, Gabriel Yin-Fat; Fu, Siu Ngor

    2017-06-01

    To examine the effect of scapular taping on the activity onset of scapular muscles and the scapular kinematics during arm elevation in volleyball players with rotator cuff (RC) tendinopathy. Randomized placebo-controlled repeated measures METHODS: Twenty-six male volleyball players with RC tendinopathy (mean age=23.6±3.3years) participated in the study. Electromyography (EMG) activity onset of upper trapezius (UT), middle trapezius (MT), lower trapezius (LT) and serratus anterior (SA) and the three-dimensional scapular kinematics quantified by using an acromial marker cluster method were compared with three scapular taping protocols, namely, no taping, therapeutic taping, and placebo taping. The MT, LT and SA activated significantly earlier in both therapeutic taping (all p<0.005) and placebo taping conditions than no taping conditions (all p<0.002). There was a small increase in the scapular upward rotation when therapeutic taping and no taping conditions were compared (p=0.007). Scapular taping may enhance the neuromotor control of the scapular muscles. Whether it provides adequate support for normal scapular kinematics during arm movement in athletes with RC tendinopathy await for further studies. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  20. Rapid prototyping of microfluidic systems using a PDMS/polymer tape composite.

    PubMed

    Kim, Jungkyu; Surapaneni, Rajesh; Gale, Bruce K

    2009-05-07

    Rapid prototyping of microfluidic systems using a combination of double-sided tape and PDMS (polydimethylsiloxane) is introduced. PDMS is typically difficult to bond using adhesive tapes due to its hydrophobic nature and low surface energy. For this reason, PDMS is not compatible with the xurography method, which uses a knife plotter and various adhesive coated polymer tapes. To solve these problems, a PDMS/tape composite was developed and demonstrated in microfluidic applications. The PDMS/tape composite was created by spinning it to make a thin layer of PDMS over double-sided tape. Then the PDMS/tape composite was patterned to create channels using xurography, and bonded to a PDMS slab. After removing the backing paper from the tape, a complete microfluidic system could be created by placing the construct onto nearly any substrate; including glass, plastic or metal-coated glass/silicon substrates. The bond strength was shown to be sufficient for the pressures that occur in typical microfluidic channels used for chemical or biological analysis. This method was demonstrated in three applications: standard microfluidic channels and reactors, a microfluidic system with an integrated membrane, and an electrochemical biosensor. The PDMS/tape composite rapid prototyping technique provides a fast and cost effective fabrication method and can provide easy integration of microfluidic channels with sensors and other components without the need for a cleanroom facility.

  1. An International Parallax Campaign to Measure Distance to the Moon and Mars

    ERIC Educational Resources Information Center

    Cenadelli, D.; Zeni, M.; Bernagozzi, A.; Calcidese, P.; Ferreira, L.; Hoang, C.; Rijsdijk, C.

    2009-01-01

    Trigonometric parallax is a powerful method to work out the distance of celestial bodies, and it was used in the past to measure the distance of the Moon, Venus, Mars and nearby stars. We set up an observation campaign for high school and undergraduate students with the purpose to measure both the Moon's and Mars' parallax. To have a large enough…

  2. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  3. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  4. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  5. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  6. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  7. Multiple-frequency continuous wave ultrasonic system for accurate distance measurement

    NASA Astrophysics Data System (ADS)

    Huang, C. F.; Young, M. S.; Li, Y. C.

    1999-02-01

    A highly accurate multiple-frequency continuous wave ultrasonic range-measuring system for use in air is described. The proposed system uses a method heretofore applied to radio frequency distance measurement but not to air-based ultrasonic systems. The method presented here is based upon the comparative phase shifts generated by three continuous ultrasonic waves of different but closely spaced frequencies. In the test embodiment to confirm concept feasibility, two low cost 40 kHz ultrasonic transducers are set face to face and used to transmit and receive ultrasound. Individual frequencies are transmitted serially, each generating its own phase shift. For any given frequency, the transmitter/receiver distance modulates the phase shift between the transmitted and received signals. Comparison of the phase shifts allows a highly accurate evaluation of target distance. A single-chip microcomputer-based multiple-frequency continuous wave generator and phase detector was designed to record and compute the phase shift information and the resulting distance, which is then sent to either a LCD or a PC. The PC is necessary only for calibration of the system, which can be run independently after calibration. Experiments were conducted to test the performance of the whole system. Experimentally, ranging accuracy was found to be within ±0.05 mm, with a range of over 1.5 m. The main advantages of this ultrasonic range measurement system are high resolution, low cost, narrow bandwidth requirements, and ease of implementation.

  8. Integration of altitude and airspeed information into a primary flight display via moving-tape formats: Evaluation during random tracking task

    NASA Technical Reports Server (NTRS)

    Abbott, Terence S.; Nataupsky, Mark; Steinmetz, George G.

    1987-01-01

    A ground-based aircraft simulation study was conducted to determine the effects on pilot preference and performance of integrating airspeed and altitude information into an advanced electronic primary flight display via moving-tape (linear moving scale) formats. Several key issues relating to the implementation of moving-tape formats were examined in this study: tape centering, tape orientation, and trend information. The factor of centering refers to whether the tape was centered about the actual airspeed or altitude or about some other defined reference value. Tape orientation refers to whether the represented values are arranged in descending or ascending order. Two pilots participated in this study, with each performing 32 runs along seemingly random, previously unknown flight profiles. The data taken, analyzed, and presented consisted of path performance parameters, pilot-control inputs, and electrical brain response measurements.

  9. A pilot study of the effect of Kinesiology tape on knee proprioception after physical activity in healthy women.

    PubMed

    Hosp, Simona; Bottoni, Giuliamarta; Heinrich, Dieter; Kofler, Philipp; Hasler, Michael; Nachbauer, Werner

    2015-11-01

    Kinesiology tape has gained significant popularity in recent years and is widely used as an adjunct for treatment and prevention of musculoskeletal injuries. However, evidence regarding its influence on knee proprioception is scarce. The purpose of this study was to evaluate the effect of Kinesiology tape on knee proprioception after physical activity in healthy women. It was hypothesized that Kinesiology tape enhances knee proprioception. Longitudinal analysis, pretest-posttest design. Twelve young women with healthy knees were tested for knee proprioception without the use of Kinesiology tape and wearing Kinesiology tape at the knee. The joint position sense was measured at the start and after a 30-min uphill walking protocol on a treadmill. Outcome was the knee angle deviation. No significant difference of proprioceptive performance between the application with Kinesiology tape and without Kinesiology tape was found after uphill walking (p > 0.05). However, when the participants' results for knee angle deviation were graded into good (< 6.1°) and poor ( > 6.1°), Kinesiology tape significantly enhanced those with poor proprioceptive ability after uphill walking, compared to the untaped knee (p = 0.002). This study has shown that the application of Kinesiology tape did not improve knee proprioception in a group of healthy young women. However, it also has demonstrated that Kinesiology tape provided significant proprioceptive enhancement at the knee joint after uphill walking in healthy women with poor proprioceptive ability. This may support its use in sports medicine for preventing knee injuries. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  10. Sub-Nanosecond Lifetime Measurement Using the Recoil-Distance Method

    PubMed Central

    Wu, Ching-Yen

    2000-01-01

    The electromagnetic properties of low-lying nuclear states are a sensitive probe of both collective and single-particle degrees of freedom in nuclear structure. The recoil-distance technique provides a very reliable, direct and precise method for measuring lifetimes of nuclear states with lifetimes ranging from less than one to several hundred picoseconds. This method complements the powerful, but complicated, heavy-ion induced Coulomb excitation technique for measuring electromagnetic properties. The recoil distance technique has been combined with heavy-ion induced Coulomb excitation to study a variety of problems. Examples discussed are: study of the two-phonon triplet in 110Pd, coupling of the β and γ degrees of freedom in 182,184W, highly deformed γ bands in 165Ho, octupole collectivity in 96Zr, and opposite parity states in 153Eu. Consistency between the Coulomb excitation results and the lifetime measurements confirms the reliability of the complex analysis often encountered in heavy-ion induced Coulomb excitation work. PMID:27551588

  11. Amobarbital treatment of multiple personality. Use of structured video tape interviews as a basis for intensive psychotherapy.

    PubMed

    Hall, R C; LeCann, A F; Schoolar, J C

    1978-09-01

    The case of a 30-year-old woman with five distinct personalities is presented. The patient was treated, using a system of structured video taped sodium amobarbital interviews, in which areas to be explored were developed in psychotherapy. Tapes were played for the patient after each session. The taped material was used as the basis for psychotherapeutic investigation. The patient evidenced many of the features previously reported in cases of multiple personality, specifically: being the product of an unwanted pregnancy in a repressively rigid family; emotional distancing by one parent; strong sibling rivalry with an adopted sib; family history of mental illness; a traumatic first sexual experience (rape); a marriage to a maladjusted individual in an attempt to escape the parental home; a high internalized standard of performance and an inability to display anger or negative feelings toward the parents. In the course of treatment, the patient's personalties fused and she was able to accept each component as part of herself. No further fragmentation has occurred during the year following discharge. The therapy technique minimized dependency, and the possiblity of addiction to amobarbital interviews permitted more active patient therapy involvement, and set clear-cut goals and expectations for improvement before further amobarbital interviews could be conducted.

  12. Kinesio Taping® is not better than placebo in reducing pain and disability in patients with chronic non-specific low back pain: a randomized controlled trial

    PubMed Central

    Luz, Maurício A.; Sousa, Manoel V.; Neves, Luciana A. F. S.; Cezar, Aline A. C.; Costa, Leonardo O. P.

    2015-01-01

    Background: Kinesio Taping ® has been widely used in clinical practice. However, it is unknown whether this type of tape is more effective than placebo taping in patients with chronic lower back pain. Objective: To compare the effectiveness of Kinesio Taping ® in patients with chronic non-specific low back pain against a placebo tape and a control group. Method: This is a 3-arm, randomized controlled trial with a blinded assessor. Sixty patients with chronic non-specific low back pain were randomized into one of the three groups: Kinesio Taping ® group (n=20), Micropore® (placebo) group (n=20) and control group (n=20). Patients allocated to both the Kinesio Taping ® group and the placebo group used the different types of tape for a period of 48 hours. The control group did not receive any intervention. The outcomes measured were pain intensity (measured by an 11-point numerical rating scale) and disability (measured by the 24-item Roland Morris Disability Questionnaire). A blinded assessor measured the outcomes at baseline, 48 hours and 7 days after randomization. Results: After 48 hours, there was a statistically significant difference between the Kinesio Taping ® group versus the control group (mean between-group difference = -3.1 points, 95% CI=-5.2 to -1.1, p=0.003), but no difference when compared to the placebo group (mean between-group difference= 1.9 points, 95% CI=-0.2 to 3.9, p=0.08). For the other outcomes no differences were observed. Conclusions: The Kinesio Taping ® is not better than placebo (Micropore®) in patients with chronic low back pain. PMID:26647750

  13. Roadmap to Measuring Distance Education Instructional Design Competencies

    ERIC Educational Resources Information Center

    Dooley, Kim E.; Lindner, James R.; Telg, Ricky W.; Irani, Tracy; Moore, Lori; Lundy, Lisa

    2007-01-01

    This study was designed to measure instructional design competencies as a result of participation in a 9-month Web-based training program called "Roadmap to Effective Distance Education Instructional Design." The researchers used a self-assessment pre- and posttest to determine participant initial and final competence in 12 areas: adult…

  14. Tree edit distance for leaf-labelled trees on free leafset and its comparison with frequent subsplit dissimilarity and popular distance measures

    PubMed Central

    2011-01-01

    Background This paper is devoted to distance measures for leaf-labelled trees on free leafset. A leaf-labelled tree is a data structure which is a special type of a tree where only leaves (terminal) nodes are labelled. This data structure is used in bioinformatics for modelling of evolution history of genes and species and also in linguistics for modelling of languages evolution history. Many domain specific problems occur and need to be solved with help of tree postprocessing techniques such as distance measures. Results Here we introduce the tree edit distance designed for leaf labelled trees on free leafset, which occurs to be a metric. It is presented together with tree edit consensus tree notion. We provide statistical evaluation of provided measure with respect to R-F, MAST and frequent subsplit based dissimilarity measures as the reference measures. Conclusions The tree edit distance was proven to be a metric and has the advantage of using different costs for contraction and pruning, therefore their properties can be tuned depending on the needs of the user. Two of the presented methods carry the most interesting properties. E(3,1) is very discriminative (having a wide range of values) and has a very regular distance distribution which is similar to a normal distribution in its shape and is good both for similar and non-similar trees. NFC(2,1) on the other hand is proportional or nearly proportional to the number of mutation operations used, irrespective of their type. PMID:21612645

  15. A Surface Energy Transfer Nanoruler for Measuring Binding Site Distances on Live Cell Surfaces

    PubMed Central

    Chen, Yan; O’Donoghue, Meghan B.; Huang, Yu-Fen; Kang, Huaizhi; Phillips, Joseph A.; Chen, Xiaolan; Estevez, M.-Carmen; Tan, Weihong

    2010-01-01

    Measuring distances at molecular length scales in living systems is a significant challenge. Methods like FRET have limitations due to short detection distances and strict orientations. Recently, surface energy transfer (SET) has been used in bulk solutions; however, it cannot be applied to living systems. Here, we have developed an SET nanoruler, using aptamer-gold-nanoparticle conjugates with different diameters, to monitor the distance between binding sites of a receptor on living cells. The nanoruler can measure separation distances well beyond the detection limit of FRET. Thus, for the first time, we have developed an effective SET nanoruler for live cells with long distance, easy construction, fast detection and low background. This is also the first time that the distance between the aptamer and antibody binding sites in the membrane protein PTK7 was measured accurately. The SET nanoruler represents the next leap forward to monitor structural components within living cell membranes. PMID:21038856

  16. Evaluating Postural Control and Ankle Laxity Between Taping and High-Top Cleats in High School Football Players.

    PubMed

    Pizac, Douglas A; Swanik, Charles B; Glutting, Joseph J; Kaminski, Thomas W

    2018-03-01

    Lateral ankle sprains are the most common injuries in high school sports. While ankle taping is a preferred method of external prophylactic support, its restrictive properties decline during exercise. The Under Armour ® Highlight cleat is marketed on the premise that it provides added support without the need for additional ankle taping. To determine if differences in ankle joint laxity and postural control exist between football players wearing the Under Armour ® Highlight cleat (Under Armour Inc, Baltimore, MD) as compared to a low/mid-top cleat with ankle tape. Crossover trial. Athletic training room and football practice field sideline. 32 interscholastic football players (15.8 ± 1.0 y; 178.9 ± 7.4 cm; 87.1 ± 21.4 kg). Ankle laxity was assessed using an instrumented ankle arthrometer (Blue Bay Research Inc, Milton, FL), while postural control testing was performed on the Tekscan MobileMat™ Balanced Error Scoring System (BESS; South Boston, MA). The 2 treatments included Under Armour ® Highlight cleats and a low/mid-top cleat with ankle tape applied to the nondominant ankle only. Measurements were taken before and immediately after practice. The independent variable was treatment (Highlight vs low/mid-top cleat with ankle tape). Dependent variables included ankle arthrometry measures of anterior displacement (mm), inversion/eversion rotation (deg), and the modified BESS error scores. A linear mixed-effects model was used for analysis. The low/mid-top cleat with tape condition had significantly higher inversion range-of-motion (ROM) and inversion/eversion rotation postexercise when compared to the Highlight cleat (P < 0.05). The results of this study provide some evidence that the Under Armour ® Highlight cleat restricts ankle ROM following a training session better than the taped low/mid-top cleat. Further study is warranted to determine if this high-top style of football cleat can reduce the incidence of ankle sprains and how it

  17. Real-Time and Meter-Scale Absolute Distance Measurement by Frequency-Comb-Referenced Multi-Wavelength Interferometry.

    PubMed

    Wang, Guochao; Tan, Lilong; Yan, Shuhua

    2018-02-07

    We report on a frequency-comb-referenced absolute interferometer which instantly measures long distance by integrating multi-wavelength interferometry with direct synthetic wavelength interferometry. The reported interferometer utilizes four different wavelengths, simultaneously calibrated to the frequency comb of a femtosecond laser, to implement subwavelength distance measurement, while direct synthetic wavelength interferometry is elaborately introduced by launching a fifth wavelength to extend a non-ambiguous range for meter-scale measurement. A linearity test performed comparatively with a He-Ne laser interferometer shows a residual error of less than 70.8 nm in peak-to-valley over a 3 m distance, and a 10 h distance comparison is demonstrated to gain fractional deviations of ~3 × 10 -8 versus 3 m distance. Test results reveal that the presented absolute interferometer enables precise, stable, and long-term distance measurements and facilitates absolute positioning applications such as large-scale manufacturing and space missions.

  18. Quality of life and objective outcome assessment in women with tape division after surgery for stress urinary incontinence

    PubMed Central

    Ulrich, Daniela; Bjelic-Radisic, Vesna; Höllein, Anna; Tamussino, Karl; Aigmüller, Thomas

    2017-01-01

    Background Midurethral tapes may cause long-term complications such as voiding dysfunction, groin pain, de novo urgency or mesh erosion, which necessitate a reoperation. There is a paucity of data regarding health related quality of life in patients undergoing tape removal. The aim of the study was to evaluate quality of life (QoL) and objective outcome after midurethral tape division or excision. Methods All patients who underwent a midurethral tape division for voiding difficulties, pain or therapy resistant de novo overactive bladder between 1999 and 2014 were invited for follow-up. A control group with a suburethral tape without division was established in a 1:2 ratio and matched for age, tape used and year of tape insertion. Patients completed the Kings´ Health Questionnaire (KHQ), Incontinence Outcome Questionnaire, Female Sexual Function Index Questionnaire and the Patient Global Impression of Improvement score. Results Tape division or excision was performed in 32 women. Overall, 15 (60%) of 25 women who were alive were available for clinical examination and completed the questionnaires. Tape division was performed for voiding dysfunction (n = 7), overactive bladder (n = 2), mesh extrusion (n = 3) and ongoing pain (n = 3). Median time to tape division/excision was 10 months. Three women in the tape division group had undergone reoperation for stress urinary incontinence (SUI). At a median follow-up of 11 years (IQR 9–13) subjective SUI rate was 53% (8/15 women) in the tape division group and 17% (5/30) in the control group (p = 0.016), with no significant differences in objective SUI rates between groups. With regard to quality of life, the study group had significantly worse scores in the SUI related domains role limitation, physical limitation, severity measures and social limitations (KHQ) compared to the control group. Conclusions Women needing tape division or excision have lower SUI related QoL scores compared to controls mostly because of higher

  19. Short-Term Effects of Kinesio Taping on Muscle Recruitment Order During a Vertical Jump: A Pilot Study.

    PubMed

    Mendez-Rebolledo, Guillermo; Ramirez-Campillo, Rodrigo; Guzman-Muñoz, Eduardo; Gatica-Rojas, Valeska; Dabanch-Santis, Alexis; Diaz-Valenzuela, Francisco

    2018-06-22

    Kinesio taping is commonly used in sports and rehabilitation settings with the aim of prevention and treatment of musculoskeletal injuries. However, limited evidence exists regarding the effects of 24 and 72 hours of kinesio taping on trunk and lower limb neuromuscular and kinetic performance during a vertical jump. The purpose of this study was to analyze the short-term effects of kinesio taping on height and ground reaction force during a vertical jump, in addition to trunk and lower limb muscle latency and recruitment order. Single-group pretest-posttest. University laboratory. Twelve male athletes from different sports (track and field, basketball, and soccer). They completed a single squat and countermovement jump at basal time (no kinesio taping), 24, and 72 hours of kinesio taping application on the gluteus maximus, biceps femoris, rectus femoris, gastrocnemius medialis, and longissimus. Muscle onset latencies were assessed by electromyography during a squat and countermovement jump, in addition to measurements of the jump height and normalized ground reaction force. The kinesio taping had no effect after 24 hours on either the countermovement or squat jump. However, at 72 hours, the kinesio taping increased the jump height (P = .02; d = 0.36) and normalized ground reaction force (P = .001; d = 0.45) during the countermovement jump. In addition, 72-hour kinesio taping reduced longissimus onset latency (P = .03; d = 1.34) and improved muscle recruitment order during a countermovement jump. These findings suggest that kinesio taping may improve neuromuscular and kinetic performance during a countermovement jump only after 72 hours of application on healthy and uninjured male athletes. However, no changes were observed on a squat jump. Future studies should incorporate a control group to verify kinesio taping's effects and its influence on injured athletes.

  20. A Tape Method for Fast Characterization and Identification of Active Pharmaceutical Ingredients in the 2-18 THz Spectral Range

    NASA Astrophysics Data System (ADS)

    Kissi, Eric Ofosu; Bawuah, Prince; Silfsten, Pertti; Peiponen, Kai-Erik

    2015-03-01

    In order to find counterfeit drugs quickly and reliably, we have developed `tape method' a transmission spectroscopic terahertz (THz) measurement technique and compared it with a standard attenuated total reflection (ATR) THz spectroscopic measurement. We used well-known training samples, which include commercial paracetamol and aspirin tablets to check the validity of these two measurement techniques. In this study, the spectral features of some active pharmaceutical ingredients (APIs), such as aspirin and paracetamol are characterized for identification purpose. This work covers a wide THz spectral range namely, 2-18 THz. This proposed simple but novel technique, the tape method, was used for characterizing API and identifying their presence in their dosage forms. By comparing the spectra of the APIs to their dosage forms (powder samples), all distinct fingerprints present in the APIs are also present in their respective dosage forms. The positions of the spectral features obtained with the ATR techniques were akin to that obtained from the tape method. The ATR and the tape method therefore, complement each other. The presence of distinct fingerprints in this spectral range has highlighted the possibility of developing fast THz sensors for the screening of pharmaceuticals. It is worth noting that, the ATR method is applicable to flat faced tablets whereas the tape method is suitable for powders in general (e.g. curved surface tablets that require milling before measurement). Finally, we have demonstrated that ATR techniques can be used to screen counterfeit antimalarial tablets.

  1. RESIDUAL RISK ASSESSMENT: MAGNETIC TAPE ...

    EPA Pesticide Factsheets

    This document describes the residual risk assessment for the Magnetic Tape Manufacturing source category. For stationary sources, section 112 (f) of the Clean Air Act requires EPA to assess risks to human health and the environment following implementation of technology-based control standards. If these technology-based control standards do not provide an ample margin of safety, then EPA is required to promulgate addtional standards. This document describes the methodology and results of the residual risk assessment performed for the Magnetic Tape Manufacturing source category. The results of this analyiss will assist EPA in determining whether a residual risk rule for this source category is appropriate.

  2. The statistical evaluation of duct tape end match as physical evidence

    NASA Astrophysics Data System (ADS)

    Chan, Ka Lok

    Duct tapes are often submitted to crime laboratories as evidence associated with abductions, homicides, or construction of explosive devices. As a result, trace evidence examiners are often asked to analyze and compare commercial duct tapes so that they can establish possible evidentiary links. Duct tape end matches are believed to be the strongest association between exemplar and question samples because they are considered as evidence with unique individual characteristics. While end match analysis and comparison have long been undertaken by trace evidence examiners, there is a significant lack of scientific research for associating two or more segments of duct tapes. This study is designed to obtain statistical inferences on the uniqueness of duct tape tears. Three experiments were devised to compile the basis for a statistical assessment of the probability of duct tape end matches along with a proposed error rate. In one experiment, we conducted the equivalent of 10,000 end match examinations with an error rate of 0%. In the second experiment, we performed 2,704 end match examinations having 0% error rate. In the third experiment, using duct tape by an Elmendorf Tear tester, we conducted 576 end match examinations with an error rate of 0% and having all samples correctly associated. The results of this study indicate that end matches are distinguishable among a single roll of duct tape and between two different rolls of duct tape having very similar surface features and weave pattern.

  3. Comparative analysis of 2D and 3D distance measurements to study spatial genome organization.

    PubMed

    Finn, Elizabeth H; Pegoraro, Gianluca; Shachar, Sigal; Misteli, Tom

    2017-07-01

    The spatial organization of genomes is non-random, cell-type specific, and has been linked to cellular function. The investigation of spatial organization has traditionally relied extensively on fluorescence microscopy. The validity of the imaging methods used to probe spatial genome organization often depends on the accuracy and precision of distance measurements. Imaging-based measurements may either use 2 dimensional datasets or 3D datasets which include the z-axis information in image stacks. Here we compare the suitability of 2D vs 3D distance measurements in the analysis of various features of spatial genome organization. We find in general good agreement between 2D and 3D analysis with higher convergence of measurements as the interrogated distance increases, especially in flat cells. Overall, 3D distance measurements are more accurate than 2D distances, but are also more susceptible to noise. In particular, z-stacks are prone to error due to imaging properties such as limited resolution along the z-axis and optical aberrations, and we also find significant deviations from unimodal distance distributions caused by low sampling frequency in z. These deviations are ameliorated by significantly higher sampling frequency in the z-direction. We conclude that 2D distances are preferred for comparative analyses between cells, but 3D distances are preferred when comparing to theoretical models in large samples of cells. In general and for practical purposes, 2D distance measurements are preferable for many applications of analysis of spatial genome organization. Published by Elsevier Inc.

  4. Chemistry of cometary meteoroids from video-tape records of meteor spectra

    NASA Technical Reports Server (NTRS)

    Millman, P. M.

    1982-01-01

    The chemistry of the cometary meteoroids was studied by closed circuit television observing systems. Vidicon cameras produce basic data on standard video tape and enable the recording of the spectra of faint shower meteors, consequently the chemical study is extended to smaller particles and we have a larger data bank than is available from the more conventional method of recording meteor spectra by photography. The two main problems in using video tape meteor spectrum records are: (1) the video tape recording has a much lower resolution than the photographic technique; (2) video tape is relatively new type of data storage in astronomy and the methods of quantitative photometry have not yet been fully developed in the various fields where video tape is used. The use of the most detailed photographic meteor spectra to calibrate the video tape records and to make positive identification of the more prominent chemical elements appearing in the spectra may solve the low resolution problem. Progress in the development of standard photometric techniques for the analysis of video tape records of meteor spectra is reported.

  5. Analysis of particulates on tape lift samples

    NASA Astrophysics Data System (ADS)

    Moision, Robert M.; Chaney, John A.; Panetta, Chris J.; Liu, De-Ling

    2014-09-01

    Particle counts on tape lift samples taken from a hardware surface exceeded threshold requirements in six successive tests despite repeated cleaning of the surface. Subsequent analysis of the particle size distributions of the failed tests revealed that the handling and processing of the tape lift samples may have played a role in the test failures. In order to explore plausible causes for the observed size distribution anomalies, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and time-of-flight secondary ion mass spectrometry (ToF-SIMS) were employed to perform chemical analysis on collected particulates. SEM/EDX identified Na and S containing particles on the hardware samples in a size range identified as being responsible for the test failures. ToF-SIMS was employed to further examine the Na and S containing particulates and identified the molecular signature of sodium alkylbenzene sulfonates, a common surfactant used in industrial detergent. The root cause investigation suggests that the tape lift test failures originated from detergent residue left behind on the glass slides used to mount and transport the tape following sampling and not from the hardware surface.

  6. Efficient Access to Massive Amounts of Tape-Resident Data

    NASA Astrophysics Data System (ADS)

    Yu, David; Lauret, Jérôme

    2017-10-01

    Randomly restoring files from tapes degrades the read performance primarily due to frequent tape mounts. The high latency and time-consuming tape mount and dismount is a major issue when accessing massive amounts of data from tape storage. BNL’s mass storage system currently holds more than 80 PB of data on tapes, managed by HPSS. To restore files from HPSS, we make use of a scheduler software, called ERADAT. This scheduler system was originally based on code from Oak Ridge National Lab, developed in the early 2000s. After some major modifications and enhancements, ERADAT now provides advanced HPSS resource management, priority queuing, resource sharing, web-browser visibility of real-time staging activities and advanced real-time statistics and graphs. ERADAT is also integrated with ACSLS and HPSS for near real-time mount statistics and resource control in HPSS. ERADAT is also the interface between HPSS and other applications such as the locally developed Data Carousel, providing fair resource-sharing policies and related capabilities. ERADAT has demonstrated great performance at BNL.

  7. Real-Time and Meter-Scale Absolute Distance Measurement by Frequency-Comb-Referenced Multi-Wavelength Interferometry

    PubMed Central

    Tan, Lilong; Yan, Shuhua

    2018-01-01

    We report on a frequency-comb-referenced absolute interferometer which instantly measures long distance by integrating multi-wavelength interferometry with direct synthetic wavelength interferometry. The reported interferometer utilizes four different wavelengths, simultaneously calibrated to the frequency comb of a femtosecond laser, to implement subwavelength distance measurement, while direct synthetic wavelength interferometry is elaborately introduced by launching a fifth wavelength to extend a non-ambiguous range for meter-scale measurement. A linearity test performed comparatively with a He–Ne laser interferometer shows a residual error of less than 70.8 nm in peak-to-valley over a 3 m distance, and a 10 h distance comparison is demonstrated to gain fractional deviations of ~3 × 10−8 versus 3 m distance. Test results reveal that the presented absolute interferometer enables precise, stable, and long-term distance measurements and facilitates absolute positioning applications such as large-scale manufacturing and space missions. PMID:29414897

  8. Effects of kinesio taping and hot packs on premenstrual syndrome in females.

    PubMed

    Choi, Jung-Hyun

    2017-09-01

    [Purpose] This study aimed to evaluate the effects of taping and hot packs on premenstrual syndrome, in an attempt to generate basic data for physical therapy intervention for premenstrual syndrome. [Subjects and Methods] Thirty-two females in their 20s with premenstrual syndrome were randomly assigned to a taping group (n=10), hot pack group (n=11), and taping with hot pack group (n=11). Premenstrual syndrome was assessed using the Menstrual Distress Questionnaire in each participant prior to intervention and was re-assessed after applying kinesio taping and/or hot pack from 10 days before the estimated date of menstruation until the first day of menstruation. [Results] Data revealed that the taping and taping with hot pack groups showed significantly reduced premenstrual syndrome following intervention. In terms of the differences in the Menstrual Distress Questionnaire total score among the groups, the taping with hot pack and hot pack groups showed a significant difference. [Conclusion] These findings indicate that kinesio taping is an easy, non-drug intervention for female college students with premenstrual syndrome.

  9. Effects of kinesio taping and hot packs on premenstrual syndrome in females

    PubMed Central

    Choi, Jung-Hyun

    2017-01-01

    [Purpose] This study aimed to evaluate the effects of taping and hot packs on premenstrual syndrome, in an attempt to generate basic data for physical therapy intervention for premenstrual syndrome. [Subjects and Methods] Thirty-two females in their 20s with premenstrual syndrome were randomly assigned to a taping group (n=10), hot pack group (n=11), and taping with hot pack group (n=11). Premenstrual syndrome was assessed using the Menstrual Distress Questionnaire in each participant prior to intervention and was re-assessed after applying kinesio taping and/or hot pack from 10 days before the estimated date of menstruation until the first day of menstruation. [Results] Data revealed that the taping and taping with hot pack groups showed significantly reduced premenstrual syndrome following intervention. In terms of the differences in the Menstrual Distress Questionnaire total score among the groups, the taping with hot pack and hot pack groups showed a significant difference. [Conclusion] These findings indicate that kinesio taping is an easy, non-drug intervention for female college students with premenstrual syndrome. PMID:28931978

  10. The immediate effects of taping therapy on knee pain and depression in patients with degenerative arthritis.

    PubMed

    Han, Ji-Won; Lee, Dong-Kyu; Park, Chi-Bok

    2018-05-01

    [Purpose] This study aims to identify the immediate effects of taping therapy on knee pain and depression among patients with degenerative arthritis. [Subjects and Methods] In total, 32 patients with degenerative arthritis were randomly assigned to one of two groups: the experimental group that underwent taping therapy and the control group that underwent regular treatment (16 patients per group). In the experimental group, therapeutic tape was wrapped all around the knee joint. Pain and depression were measured using the visual analogue scale (VAS) and the Beck Depression Inventory (BDI), respectively. [Results] The intra-group comparison showed significant differences in VAS and BDI for the experimental group. The intergroup comparison showed that the differences in VAS and BDI within the experimental group appeared significant relative to the control group. [Conclusion] It was observed that taping therapy showed an immediate effect in decreasing knee pain and depression among patients with degenerative arthritis.

  11. Digital optical tape: Technology and standardization issues

    NASA Technical Reports Server (NTRS)

    Podio, Fernando L.

    1996-01-01

    During the coming years, digital data storage technologies will continue an aggressive growth to satisfy the user's need for higher storage capacities, higher data transfer rates and long-term archival media properties. Digital optical tape is a promising technology to satisfy these user's needs. As any emerging data storage technology, the industry faces many technological and standardization challenges. The technological challenges are great, but feasible to overcome. Although it is too early to consider formal industry standards, the optical tape industry has decided to work together by initiating prestandardization efforts that may lead in the future to formal voluntary industry standards. This paper will discuss current industry optical tape drive developments and the types of standards that will be required for the technology. The status of current industry prestandardization efforts will also be discussed.

  12. Dialects for the Stage: A Manual and Two Casette Tapes.

    ERIC Educational Resources Information Center

    Machlin, Evangeline

    This document contains a manual and two cassette tapes designed to help actors and actresses learn to speak various dialects. The tapes and the manual are arranged for the play-it-and-say-it method of dialect acquisition. The first three parts discuss the tapes and the manual in general, the dialect texts and dialect data, and the steps involved…

  13. Freeze Tape Casting of Functionally Graded Porous Ceramics

    NASA Technical Reports Server (NTRS)

    Sofie, Stephen W.

    2007-01-01

    Freeze tape casting is a means of making preforms of ceramic sheets that, upon subsequent completion of fabrication processing, can have anisotropic and/or functionally graded properties that notably include aligned and graded porosity. Freeze tape casting was developed to enable optimization of the microstructures of porous ceramic components for use as solid oxide electrodes in fuel cells: Through alignment and grading of pores, one can tailor surface areas and diffusion channels for flows of gas and liquid species involved in fuel-cell reactions. Freeze tape casting offers similar benefits for fabrication of optimally porous ceramics for use as catalysts, gas sensors, and filters.

  14. Multilingual health education tapes project.

    PubMed

    Vryheid, R

    1992-01-01

    The success of Thailand's 1985 malaria education cassette tapes project motivated the Highland Development Program to produce tapes in 6 tribal languages on family planning, maternal and child health, nutrition, and disease prevention. Staff produced tapes using a drama or radio magazine format as a series of short features with music and sound effects. Scriptwriters consulted villagers, broadcasting professionals, research workers, and health officials to tailor messages to the various hill tribes. They tried to avoid conflict between traditional and modern concepts and to minimize distrust of government services. The scriptwriters used basically short, grammatically simple sentences, and colloquial Thai to simplify translation. The staff tried to recruit literate, adult, native speakers of the target languages with some experience in health education in their own languages. Obstacles encountered with translation included some languages used an uncommon alphabet or translators did not know their own alphabet. The program backtranslated the scripts to assure the accuracy of the messages and the appropriateness of the words used. Backtranslation revealed deficiencies in the translated messages. Altering the meaning of technical terms tended to be simple mistakes, words with multiple meanings, and exaggeration of problems and/or solutions. Translators also sometimes failed to adapt cultural ideas to those of their tribes. For example, some persons translated all possible misconceptions about a disease yet the tribes did not have all the misconceptions. As of early 1992, recording, pretesting, distribution, and follow up had not yet taken place. The staff should meet with a recording studio to coordinate production including technicians and translators identifying means to communicate. Staff should be aware of signs of poor translation which they may have missed earlier and surfaces during recording. Pretesting should occur among literate and illiterate members of

  15. A Meta-Analysis of the Taped Problems Intervention

    ERIC Educational Resources Information Center

    Kleinert, Whitney L.; Codding, Robin S.; Minami, Takuya; Gould, Kaitlin

    2018-01-01

    Taped problems is an intervention strategy for addressing mathematics fluency that has been evaluated in multiple single-case design studies. Although its efficacy has been supported in individual studies, no comprehensive quantitative synthesis has been conducted on taped problems. The purpose of this study was to synthesize the literature that…

  16. Ankle taping: support given by different materials.

    PubMed Central

    Capasso, G; Maffulli, N; Testa, V

    1989-01-01

    Three different adhesive and two non-adhesive tapes were used by three operators to assess the compressive action exerted on the ankle at the moment of strapping, during different phases of gait, and after some days of treatment in ten volunteers. Only the adhesive tapes were still able to prevent swelling after five days. They should be used if a prolonged compressive action is required. Images Figure 1 PMID:2517042

  17. Materials for Heated Head Automated Thermoplastic Tape Placement

    NASA Technical Reports Server (NTRS)

    Jensen, Brian J.; Kinney, Megan C.; Cano, Roberto J.; Grimsley, Brian W.

    2012-01-01

    NASA Langley Research Center (LaRC) is currently pursuing multiple paths to develop out of autoclave (OOA) polymeric composite materials and processes. Polymeric composite materials development includes the synthesis of new and/or modified thermosetting and thermoplastic matrix resins designed for specific OOA processes. OOA processes currently under investigation include vacuum bag only (VBO) prepreg/composite fabrication, resin transfer molding (RTM), vacuum assisted resin transfer molding (VARTM) and heated head automated thermoplastic tape placement (HHATP). This paper will discuss the NASA Langley HHATP facility and capabilities and recent work on characterizing thermoplastic tape quality and requirements for quality part production. Samples of three distinct versions of APC-2 (AS4/PEEK) thermoplastic dry tape were obtained from two materials vendors, TENCATE, Inc. and CYTEC Engineered Materials** (standard grade and an experimental batch). Random specimens were taken from each of these samples and subjected to photo-microscopy and surface profilometry. The CYTEC standard grade of APC-2 tape had the most voids and splits and the highest surface roughness and/or waviness. Since the APC-2 tape is composed of a thermoplastic matrix, it offers the flexibility of reprocessing to improve quality, and thereby improve final quality of HHATP laminates. Discussions will also include potential research areas and future work that is required to advance the state of the art in the HHATP process for composite fabrication.

  18. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    DOEpatents

    Goyal, Amit

    2013-07-09

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  19. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    DOEpatents

    Goyal, Amit [Knoxville, TN

    2012-07-24

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  20. Chandra Shows New Way to Measure Cosmic Distances

    NASA Astrophysics Data System (ADS)

    2000-04-01

    Using NASA's Chandra X-ray Observatory, a team of scientists has attacked one of astronomy's oldest and thorniest problems, determining the distance to a cosmic object. Through measuring the distance to an X-ray source by observing the delay and smearing out of X-ray signals traversing 30,000 light years of interstellar gas and dust, Chandra "opened a new world," said Peter Predehl of the Max-Planck Institute, Garching, Germany, the lead author on a report to be published in the European journal, Astronomy and Astrophysics. "Geometrical distance measurements are of particular importance for astronomy. Now we have a new method that works for distant sources," Predehl said. One of the most crucial pieces of information needed in astronomy is the distance to the stars and galaxies. They are also among the most difficult to obtain because, with rare exceptions, astronomers cannot measure distance directly and must use a variety of ingenious but uncertain techniques. This new method relies on the scattering of X-rays by interstellar dust grains between a source and the Earth. Although the scattering material is different, the dust produces a halo, much like the halo around a traffic light on a foggy night. "When the light switches from red to green (or vice versa), the halo around the light is also slightly delayed," Predehl explained. "No one would use this delay for determining the distance to the traffic light, of course, (the delay is only a few billionths of a second). But if the 'traffic light' is 30,000 light years away, the delay is on the order 15 minutes. Using the excellent and unprecedented resolution of the Chandra observatory, we can distinguish between light which was 30,000 years on its way and other light which needed only a few minutes more. " Other members of the team included Vadim Burwitz and Joachim Trumper, also of the Max-Planck Institute, and Frits Paerels of Columbia University, New York. Trumper and a colleague proposed using this method 27

  1. [Efficacy of the application of kinesio tape in patients with stroke].

    PubMed

    Ortiz-Ramirez, J; Perez-De la Cruz, S

    2017-02-16

    To review the effects achieved by the kinesio tape in patients with stroke in scientific studies published on date and to discuss these findings may be of interest to neurology. An exhaustive search in the main scientific databases using keywords such as kinesio tape, kinesiotaping, musculoskeletal tape, taping medical concept was carried out. Citations of selected articles and scientific papers published on the website of the Spanish Association of Neuromuscular Bandage were analyzed. Experimental, quasi-experimental, clinical trials and case studies published were used, without limit date, with therapeutical treatment purpose provide important results. Eight articles have met the inclusion criteria. There are eight studies that examine the effect on kinesio tape on lower limb, gait and balance in this kind of therapy, even upper limb and swallowing problems that these patients could present. The kinesio tape in neurological patients can be a complementary technique that empirically provides benefits. However, better methodological quality studies demonstrating the effects attributed to him are still needed.

  2. Recovery of recordings from heat damaged magnetic tapes

    NASA Technical Reports Server (NTRS)

    Melugin, J. F.; Obrien, D. E., III

    1973-01-01

    Damaged tapes can now be repaired at home as long as damage does not extend to layer-to-layer adhesion within tape roll. Splice repaired section into good roll or cassette for copying. Every effort should be made to complete copying on first run, because fidelity in repaired section deteriorates with each repetition.

  3. Measuring Transactional Distance in Web-Based Learning Environments: An Initial Instrument Development

    ERIC Educational Resources Information Center

    Huang, Xiaoxia; Chandra, Aruna; DePaolo, Concetta; Cribbs, Jennifer; Simmons, Lakisha

    2015-01-01

    This study was an initial attempt to operationalise Moore's transactional distance theory by developing and validating an instrument measuring the related constructs: dialogue, structure, learner autonomy and transactional distance. Data were collected from 227 online students and analysed through an exploratory factor analysis. Results suggest…

  4. Application of distance correction to ChemCam laser-induced breakdown spectroscopy measurements

    DOE PAGES

    Mezzacappa, A.; Melikechi, N.; Cousin, A.; ...

    2016-04-04

    Laser-induced breakdown spectroscopy (LIBS) provides chemical information from atomic, ionic, and molecular emissions from which geochemical composition can be deciphered. Analysis of LIBS spectra in cases where targets are observed at different distances, as is the case for the ChemCam instrument on the Mars rover Curiosity, which performs analyses at distances between 2 and 7.4 m is not a simple task. Previously, we showed that spectral distance correction based on a proxy spectroscopic standard created from first-shot dust observations on Mars targets ameliorates the distance bias in multivariate-based elemental-composition predictions of laboratory data. In this work, we correct an expandedmore » set of neutral and ionic spectral emissions for distance bias in the ChemCam data set. By using and testing different selection criteria to generate multiple proxy standards, we find a correction that minimizes the difference in spectral intensity measured at two different distances and increases spectral reproducibility. When the quantitative performance of distance correction is assessed, there is improvement for SiO 2, Al 2O 3, CaO, FeOT, Na 2O, K 2O, that is, for most of the major rock forming elements, and for the total major-element weight percent predicted. But, for MgO the method does not provide improvements while for TiO 2, it yields inconsistent results. Additionally, we observed that many emission lines do not behave consistently with distance, evidenced from laboratory analogue measurements and ChemCam data. This limits the effectiveness of the method.« less

  5. Feasibility model of a high reliability five-year tape transport, volume 2

    NASA Technical Reports Server (NTRS)

    Eshleman, R. L.; Meyers, A. P.; Davidson, W. A.; Gortowski, R. C.; Anderson, M. E.

    1973-01-01

    Analysis of the design features of the modularized tape transport renders a life expectancy in excess of five years. Tests performed on the tape transport were directed toward determining its performance capability. These tests revealed that the tape jitter and skew are in the range achieved by high quality digital tape transports. Guidance of the tape in the lateral sense by the use of the two hybrid crowned rollers proved to be excellent. Tracking was maintained within less than one thousandth inch (approximately 2 micrometers). The guidance capability demonstrated makes possible the achievement of the performance objective of 7.2 x 10 to the 9th power storage capability employing 1500 ft. of one inch wide tape with a packing density of 5,000 bits per inch per track on 80 tracks. Also, the machine showed excellent characteristics operating over a wide range of tape speeds. The basic design concept lends itself to growth and adaptation to a wide range of recorder requirements.

  6. Kinesiology tape mediates soccer-simulated and local peroneal fatigue in soccer players.

    PubMed

    Farquharson, Claire; Greig, Matt

    2017-01-01

    To investigate the efficacy of kinesiology taping in mediating the influence of fatigue on ankle sprain risk, 12 male soccer players completed single-leg dynamic balance trials pre- and post-exercise (soccer-specific protocol, isokinetic ankle inversion/eversion protocol) in each of three counter-balanced taping conditions (no tape, zinc oxide tape ZO, kinesiology tape KT). Balance was quantified as the overall stability index (OSI) and directional stability indices of platform deflection. Soccer-specific fatigue only increased OSI in the no tape condition (p = 0.03), with ZO and KT trials negating a fatigue affect. Localized fatigue increased OSI in the no tape (p = 0.01) and ZO (p = 0.05) trials, with no increase in the KT trial. A similar pattern was observed in medio-lateral and anterio-posterior balance indices. KT mediates soccer-simulated and local peroneal fatigue, with practical implications for epidemiological observations of increased injury risk during the latter stages of match play.

  7. Inertial and stick-slip regimes of unstable adhesive tape peeling.

    PubMed

    Dalbe, Marie-Julie; Villey, Richard; Ciccotti, Matteo; Santucci, Stéphane; Cortet, Pierre-Philippe; Vanel, Loïc

    2016-05-18

    We present an experimental characterization of the detachment front unstable dynamics observed during the peeling of pressure sensitive adhesives. We use an experimental set-up specifically designed to control the peeling angle θ and the peeled tape length L, while peeling an adhesive tape from a flat substrate at a constant driving velocity V. High-speed imaging allows us to report the evolution of the period and amplitude of the front oscillations, as well as the relative durations of their fast and slow phases, as a function of the control parameters V, L and θ. Our study shows that, as the driving velocity or the peeling angle increases, the oscillations of the peeling front progressively evolve from genuine "stick-slip" oscillations, made of alternating long stick phases and very brief slip phases, to sinusoidal oscillations of amplitude twice the peeling velocity. We propose a model which, taking into account the peeling angle-dependent kinetic energy cost to accelerate and decelerate the peeled tape, explains the transition from the "stick-slip" to the "inertial" regime of the dynamical instability. Using independent direct measurements of the effective fracture energy of the adhesive-substrate joint, we show that our model quantitatively accounts for the two regimes of the unstable dynamics.

  8. Mirror-touch and ticker tape experiences in synesthesia

    PubMed Central

    Chun, Charlotte A.; Hupé, Jean-Michel

    2013-01-01

    A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia's connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person's arm being stroked can evoke physical touch sensation on one's own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker's mouth. To explore synesthesia's associations with these phenomena, a diverse group (n = 3743) was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1017 eligible respondents, synesthetes (across all subtypes) reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However, effect sizes were small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2–4%) and sequence-space synesthesia (9–14%). Within synesthesia, grapheme-personification, also called ordinal-linguistic personification (OLP) was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect sizes. PMID

  9. An Experimental Investigation of Damaged Arresting Gear Tapes for the Langley Aircraft Landing Dynamics Facility

    NASA Technical Reports Server (NTRS)

    Mason, Angela J.

    1999-01-01

    An experimental investigation was performed on damaged arresting gear tapes at the Langley Aircraft Landing Dynamics Facility. The arrestment system uses five pairs of tapes to bring the test carriage to a halt. The procedure used to determine when to replace the tapes consists of a close evaluation of each of the 10 tapes after each run. During this evaluation, each tape is examined thoroughly and any damage observed on the tape is recorded. If the damaged tape does not pass the inspection, the tape is replaced with a new one. For the past 13 years, the most commonly seen damage types are edge fray damage and transverse damage. Tests were conducted to determine the maximum tensile strength of a damaged arresting gear tape specimen. The data indicate that tapes exhibiting transverse damage can withstand higher loads than tapes with edge fray damage.

  10. Applying Statistical Models and Parametric Distance Measures for Music Similarity Search

    NASA Astrophysics Data System (ADS)

    Lukashevich, Hanna; Dittmar, Christian; Bastuck, Christoph

    Automatic deriving of similarity relations between music pieces is an inherent field of music information retrieval research. Due to the nearly unrestricted amount of musical data, the real-world similarity search algorithms have to be highly efficient and scalable. The possible solution is to represent each music excerpt with a statistical model (ex. Gaussian mixture model) and thus to reduce the computational costs by applying the parametric distance measures between the models. In this paper we discuss the combinations of applying different parametric modelling techniques and distance measures and weigh the benefits of each one against the others.

  11. 21 CFR 878.4730 - Surgical skin degreaser or adhesive tape solvent.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical skin degreaser or adhesive tape solvent... Surgical skin degreaser or adhesive tape solvent. (a) Identification. A surgical skin degreaser or an... dissolve surface skin oil or adhesive tape. (b) Classification. Class I (general controls). The device is...

  12. Measuring the Accuracy of Simple Evolving Connectionist System with Varying Distance Formulas

    NASA Astrophysics Data System (ADS)

    Al-Khowarizmi; Sitompul, O. S.; Suherman; Nababan, E. B.

    2017-12-01

    Simple Evolving Connectionist System (SECoS) is a minimal implementation of Evolving Connectionist Systems (ECoS) in artificial neural networks. The three-layer network architecture of the SECoS could be built based on the given input. In this study, the activation value for the SECoS learning process, which is commonly calculated using normalized Hamming distance, is also calculated using normalized Manhattan distance and normalized Euclidean distance in order to compare the smallest error value and best learning rate obtained. The accuracy of measurement resulted by the three distance formulas are calculated using mean absolute percentage error. In the training phase with several parameters, such as sensitivity threshold, error threshold, first learning rate, and second learning rate, it was found that normalized Euclidean distance is more accurate than both normalized Hamming distance and normalized Manhattan distance. In the case of beta fibrinogen gene -455 G/A polymorphism patients used as training data, the highest mean absolute percentage error value is obtained with normalized Manhattan distance compared to normalized Euclidean distance and normalized Hamming distance. However, the differences are very small that it can be concluded that the three distance formulas used in SECoS do not have a significant effect on the accuracy of the training results.

  13. Effects of Preventative Ankle Taping on Planned Change-of-Direction and Reactive Agility Performance and Ankle Muscle Activity in Basketballers

    PubMed Central

    Jeffriess, Matthew D.; Schultz, Adrian B.; McGann, Tye S.; Callaghan, Samuel J.; Lockie, Robert G.

    2015-01-01

    This study investigated the effects of preventative ankle taping on planned change-of-direction and reactive agility performance and peak ankle muscle activity in basketballers. Twenty male basketballers (age = 22.30 ± 3.97 years; height = 1.84 ± 0.09 meters; body mass = 85.96 ± 11.88 kilograms) with no ankle pathologies attended two testing sessions. Within each session, subjects completed six planned and six reactive randomized trials (three to the left and three to the right for each condition) of the Y-shaped agility test, which was recorded by timing lights. In one session, subjects had both ankles un-taped. In the other, both ankles were taped using a modified subtalar sling. Peak tibialis anterior, peroneus longus (PL), peroneus brevis (PB), and soleus muscle activity was recorded for both the inside and outside legs across stance phase during the directional change, which was normalized against 10-meter sprint muscle activity (nEMG). Both the inside and outside cut legs during the change-of-direction step were investigated. Repeated measures ANOVA determined performance time and nEMG differences between un-taped and taped conditions. There were no differences in planned change-of-direction or reactive agility times between the conditions. Inside cut leg PL nEMG decreased when taped for the planned left, reactive left, and reactive right cuts (p = 0.01). Outside leg PB and soleus nEMG increased during the taped planned left cut (p = 0.02). There were no other nEMG changes during the cuts with taping. Taping did not affect change-of-direction or agility performance. Inside leg PL activity was decreased, possibly due to the tape following the line of muscle action. This may reduce the kinetic demand for the PL during cuts. In conclusion, ankle taping did not significantly affect planned change-of-direction or reactive agility performance, and did not demonstrate large changes in activity of the muscle complex in healthy basketballers. Key points Ankle

  14. Effect of Mulligan's and Kinesio knee taping on adolescent ballet dancers knee and hip biomechanics during landing.

    PubMed

    Hendry, D; Campbell, A; Ng, L; Grisbrook, T L; Hopper, D M

    2015-12-01

    Taping is often used to manage the high rate of knee injuries in ballet dancers; however, little is known about the effect of taping on lower-limb biomechanics during ballet landings in the turnout position. This study investigated the effects of Kinesiotape (KT), Mulligan's tape (MT) and no tape (NT) on knee and hip kinetics during landing in three turnout positions. The effect of taping on the esthetic execution of ballet jumps was also assessed. Eighteen pain-free 12-15-year-old female ballet dancers performed ballet jumps in three turnout positions, under the three knee taping conditions. A Vicon Motion Analysis system (Vicon Oxford, Oxford, UK) and Advanced Mechanical Technology, Inc. (Watertown, Massa chusetts, USA) force plate collected lower-limb mechanics. The results demonstrated that MT significantly reduced peak posterior knee shear forces (P = 0.025) and peak posterior (P = 0.005), medial (P = 0.022) and lateral (P = 0.014) hip shear forces compared with NT when landing in first position. KT had no effect on knee or hip forces. No significant differences existed between taping conditions in all landing positions for the esthetic measures. MT was able to reduce knee and the hip forces without affecting the esthetic performance of ballet jumps, which may have implications for preventing and managing knee injuries in ballet dancers. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Induction Bonding of Prepreg Tape and Titanium Foil

    NASA Technical Reports Server (NTRS)

    Messier, Bernadette C.; Hinkley, Jeffrey A.; Johnston, Norman J.

    1998-01-01

    Hybrid structural laminates made of titanium foil and carbon fiber reinforced polymer composite offer a potential for improved performance in aircraft structural applications. To obtain information needed for the automated fabrication of hybrid laminates, a series of bench scale tests were conducted of the magnetic induction bonding of titanium foil and thermoplastic prepreg tape. Foil and prepreg specimens were placed in the gap of a toroid magnet mounted in a bench press. Several magnet power supplies were used to study power at levels from 0.5 to 1.75 kW and frequencies from 50 to 120 kHz. Sol-gel surface-treated titanium foil, 0.0125 cm thick, and PIXA/IM7 prepreg tape were used in several lay-up configurations. Data were obtained on wedge peel bond strength, heating rate, and temperature ramp over a range of magnet power levels and frequencies at different "power-on" times for several magnet gap dimensions. These data will be utilized in assessing the potential for automated processing. Peel strengths of foil-tape bonds depended on the maximum temperature reached during heating and on the applied pressure. Maximum peel strengths were achieved at 1.25kW and 8OkHz. Induction heating of the foil appears to be capable of good bonding up to 10 plies of tape. Heat transfer calculations indicate that a 20-40 C temperature difference exists across the tape thickness during heat-up.

  16. Recoil distance lifetime measurements in82Kr

    NASA Astrophysics Data System (ADS)

    Brüssermann, S.; Keinonen, J.; Hellmeister, H. P.; Lieb, K. P.

    1982-12-01

    The lifetimes τ=124±12, 6{-2/+4} and 380±100 ps of the E x ( I π )=3.46(8+), 2.92(6+) and 3.04(6-) MeV states, respectively, populated by the reaction76Ge(12C, α2 n) were measured with the recoil distance method. In addition upper lifetime limits were obtained for nine states. The measured lifetimes and energies indicate a band crossing at about I π =8+, probably arising from the alignment of two g 9/2 neutrons. For the 3.04 MeV 6- state as a second member of a band built on the 2.65 MeV 4- state the measured lifetime points to a two-quasiparticle configuration. The positive-parity states have been discussed in the frame of the interacting boson approximation, nuclear field theory and the cranked shell model.

  17. Report of the Tape Recorder Action Plan Committee, 21 March 1972

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A NASA/AF Tape Recorder Action Plan Committee was formed in January 1972 to investigate tape recorder problems and to recommend an action plan to NASA management. The committee collected data on tape recorder failure history, pinpointed problem areas, discussed needed technical and management changes, and proposed an action plan for the recommended approaches.

  18. Interpretation of the human skin biotribological behaviour after tape stripping.

    PubMed

    Pailler-Mattei, C; Guerret-Piécourt, C; Zahouani, H; Nicoli, S

    2011-07-06

    The present study deals with the modification of the human skin biotribological behaviour after tape stripping. The tape-stripping procedure consists in the sequential application and removal of adhesive tapes on the skin surface in order to remove stratum corneum (SC) layers, which electrically charges the skin surface. The skin electric charges generated by tape stripping highly change the skin friction behaviour by increasing the adhesion component of the skin friction coefficient. It has been proposed to rewrite the friction adhesion component as the sum of two terms: the first classical adhesion term depending on the intrinsic shear strength, τ(0), and the second term depending on the electric shear strength, τ(elec). The experimental results allowed to estimate a numerical value of the electric shear strength τ(elec). Moreover, a plan capacitor model with a dielectric material inside was used to modelize the experimental system. This physical model permitted to evaluate the friction electric force and the electric shear strength values to calculate the skin friction coefficient after the tape stripping. The comparison between the experimental and the theoretical value of the skin friction coefficient after the tape stripping has shown the importance of the electric charges on skin biotribological behaviour. The static electric charges produced by tape stripping on the skin surface are probably able to highly modify the interaction of formulations with the skin surface and their spreading properties. This phenomenon, generally overlooked, should be taken into consideration as it could be involved in alteration of drug absorption.

  19. Interpretation of the human skin biotribological behaviour after tape stripping

    PubMed Central

    Pailler-Mattei, C.; Guerret-Piécourt, C.; Zahouani, H.; Nicoli, S.

    2011-01-01

    The present study deals with the modification of the human skin biotribological behaviour after tape stripping. The tape-stripping procedure consists in the sequential application and removal of adhesive tapes on the skin surface in order to remove stratum corneum (SC) layers, which electrically charges the skin surface. The skin electric charges generated by tape stripping highly change the skin friction behaviour by increasing the adhesion component of the skin friction coefficient. It has been proposed to rewrite the friction adhesion component as the sum of two terms: the first classical adhesion term depending on the intrinsic shear strength, τ0, and the second term depending on the electric shear strength, τelec. The experimental results allowed to estimate a numerical value of the electric shear strength τelec. Moreover, a plan capacitor model with a dielectric material inside was used to modelize the experimental system. This physical model permitted to evaluate the friction electric force and the electric shear strength values to calculate the skin friction coefficient after the tape stripping. The comparison between the experimental and the theoretical value of the skin friction coefficient after the tape stripping has shown the importance of the electric charges on skin biotribological behaviour. The static electric charges produced by tape stripping on the skin surface are probably able to highly modify the interaction of formulations with the skin surface and their spreading properties. This phenomenon, generally overlooked, should be taken into consideration as it could be involved in alteration of drug absorption. PMID:21227961

  20. Compilation of fatigue, fatigue-crack propagation, and fracture data for 2024 and 7075 aluminum, Ti-6Al-4V titanium, and 300M steel. Volume 1: Description of data and data storage on magnetic tape. Volume 2: Data tape (7-track magnetic tape)

    NASA Technical Reports Server (NTRS)

    Rice, R. C.; Reynolds, J. L.

    1976-01-01

    Fatigue, fatigue-crack-propagation, and fracture data compiled and stored on magnetic tape are documented. Data for 202 and 7075 aluminum alloys, Ti-6Al-4V titanium alloy, and 300M steel are included in the compilation. Approximately 4,500 fatigue, 6,500 fatigue-crack-propagation, and 1,500 fracture data points are stored on magnetic tape. Descriptions of the data, an index to the data on the magnetic tape, information on data storage format on the tape, a listing of all data source references, and abstracts of other pertinent test information from each data source reference are included.

  1. How far is it? Distance measurements and their consequences

    NASA Astrophysics Data System (ADS)

    Krełowski, Jacek

    2017-08-01

    Methods of measuring distances to objects in our Milky Way are briefly discussed. They generally base on three principles: of using a standard rod, of standard candle and of column density of interstellar matter. Weak and strong points of these methods are presented. The presence of gray extinction towards some objects is suggested which makes the most universal method of standard candle (spectroscopic parallax) very uncertain. Hard to say whether gray extinc-tion appears only in the form of circumstellar debris discs or is present also in the general interstellar medium. The application of the method of measuring column densities of interstellar gases suggests that the rotation curve of our Milky Way system is rather Keplerian than flat which creates doubts as to whether any Dark Matter halo is present around our Galaxy. It is emphasized that the most universal method, i.e. that of standard candle, used to estimate distances to cosmological objects, may suffer serious errors because of improper subtraction of extinction effects.

  2. An efficient, modular and simple tape archiving solution for LHC Run-3

    NASA Astrophysics Data System (ADS)

    Murray, S.; Bahyl, V.; Cancio, G.; Cano, E.; Kotlyar, V.; Kruse, D. F.; Leduc, J.

    2017-10-01

    The IT Storage group at CERN develops the software responsible for archiving to tape the custodial copy of the physics data generated by the LHC experiments. Physics run 3 will start in 2021 and will introduce two major challenges for which the tape archive software must be evolved. Firstly the software will need to make more efficient use of tape drives in order to sustain the predicted data rate of 150 petabytes per year as opposed to the current 50 petabytes per year. Secondly the software will need to be seamlessly integrated with EOS, which has become the de facto disk storage system provided by the IT Storage group for physics data. The tape storage software for LHC physics run 3 is code named CTA (the CERN Tape Archive). This paper describes how CTA will introduce a pre-emptive drive scheduler to use tape drives more efficiently, will encapsulate all tape software into a single module that will sit behind one or more EOS systems, and will be simpler by dropping support for obsolete backwards compatibility.

  3. Tools for applying lead tape to flat conductor cabling for chemical stripping

    NASA Technical Reports Server (NTRS)

    Angele, W.

    1969-01-01

    Two tools facilitate chemical stripping of insulation on flat conductor cabling. A tape pressing tool and a taping fixture apply adhesive lead tape with the proper amount of pressure to protect the remaining insulation from the chemical stripping solution.

  4. Generation and physical characteristics of the ERTS MSS system corrected computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1973-01-01

    The generation and format are discussed of the ERTS system corrected multispectral scanner computer compatible tapes. The discussion includes spacecraft sensors, scene characteristics, data transmission, and conversion of data to computer compatible tapes at the NASA Data Processing Facility. Geometeric and radiometric corrections, tape formats, and the physical characteristics of the tapes are also included.

  5. The effective resistance between twisted superconducting filaments in tapes

    NASA Astrophysics Data System (ADS)

    Takács, S.; Iwakuma, M.; Funaki, K.

    2001-05-01

    We consider two mechanisms, which influence the effective resistance between crossing strands on flat cables or filaments in twisted tapes. The one-layer classical Rutherford-type cable and the tapes with twisted BSCCO filaments in silver matrix are taken as analogous cases. The amount of the matrix between strands or filaments increases the effective conductance compared with the direct current paths (determined by the touching area of the filaments). The increase factor is about two and can easily be suppressed by other effects, like the contact resistance between the superconductor and the matrix. The second mechanism is due to the existence of induced voltage between any points of crossing filaments. This leads to an additional effective conductance, proportional to the square of the total number of filaments. Both effects are not very important for isotropic superconductors, but due to the strong anisotropy of critical parameters they can dominate for high temperature superconductors. The first one may partially compensate the influence of the usually weaker critical current density perpendicular to the tape. The contribution due to the second effect can explain the higher resistivity of the matrix in BSCCO tapes compared with pure silver. It seems that to obtain low AC coupling losses in BSCCO tapes, structures with small filament number are required.

  6. Measurement of a Cosmographic Distance Ratio with Galaxy and Cosmic Microwave Background Lensing.

    PubMed

    Miyatake, Hironao; Madhavacheril, Mathew S; Sehgal, Neelima; Slosar, Anže; Spergel, David N; Sherwin, Blake; van Engelen, Alexander

    2017-04-21

    We measure the gravitational lensing shear signal around dark matter halos hosting constant mass galaxies using light sources at z∼1 (background galaxies) and at the surface of last scattering at z∼1100 (the cosmic microwave background). The galaxy shear measurement uses data from the CFHTLenS survey, and the microwave background shear measurement uses data from the Planck satellite. The ratio of shears from these cross-correlations provides a purely geometric distance measurement across the longest possible cosmological lever arm. This is because the matter distribution around the halos, including uncertainties in galaxy bias and systematic errors such as miscentering, cancels in the ratio for halos in thin redshift slices. We measure this distance ratio in three different redshift slices of the constant mass (CMASS) sample and combine them to obtain a 17% measurement of the distance ratio, r=0.390_{-0.062}^{+0.070}, at an effective redshift of z=0.53. This is consistent with the predicted ratio from the Planck best-fit cold dark matter model with a cosmological constant cosmology of r=0.419.

  7. Exploring the effects of tape-recording on personality assessment.

    PubMed

    Lichton, A I; Waehler, C A

    1999-06-01

    This study examined the possible influence of audio and video recording of personality assessment measures on anxiety. Undergraduate students in psychology were randomly assigned to Audiotape, Videotape, or Control conditions and given the State-Trait Anxiety Inventory and Rorschach Inkblot Method. A one-way multivariate analysis of variance indicated no significant differences among these conditions on the Spielberger, et al. State-Trait Anxiety Inventory, A-State scale, and five Rorschach measures of situational anxiety. Tape-recording itself did not seem to affect the anxiety indices of these frequently used personality assessments.

  8. Effectiveness of workplace social distancing measures in reducing influenza transmission: a systematic review.

    PubMed

    Ahmed, Faruque; Zviedrite, Nicole; Uzicanin, Amra

    2018-04-18

    Social distancing is one of the community mitigation measures that may be recommended during influenza pandemics. Social distancing can reduce virus transmission by increasing physical distance or reducing frequency of congregation in socially dense community settings, such as schools or workplaces. We conducted a systematic review to assess the evidence that social distancing in non-healthcare workplaces reduces or slows influenza transmission. Electronic searches were conducted using MEDLINE, Embase, Scopus, Cochrane Library, PsycINFO, CINAHL, NIOSHTIC-2, and EconLit to identify studies published in English from January 1, 2000, through May 3, 2017. Data extraction was done by two reviewers independently. A narrative synthesis was performed. Fifteen studies, representing 12 modeling and three epidemiological, met the eligibility criteria. The epidemiological studies showed that social distancing was associated with a reduction in influenza-like illness and seroconversion to 2009 influenza A (H1N1). However, the overall risk of bias in the epidemiological studies was serious. The modeling studies estimated that workplace social distancing measures alone produced a median reduction of 23% in the cumulative influenza attack rate in the general population. It also delayed and reduced the peak influenza attack rate. The reduction in the cumulative attack rate was more pronounced when workplace social distancing was combined with other nonpharmaceutical or pharmaceutical interventions. However, the effectiveness was estimated to decline with higher basic reproduction number values, delayed triggering of workplace social distancing, or lower compliance. Modeling studies support social distancing in non-healthcare workplaces, but there is a paucity of well-designed epidemiological studies. PROSPERO registration # CRD42017065310.

  9. Surreptitious Taping: The Arguments for and the Ethics against.

    ERIC Educational Resources Information Center

    Cooper, Thomas W.

    Much discussion within media ethics has focused on the acceptability of surreptitious tape recording of news sources by media professionals. The most common legal and social arguments supporting secret taping assert that recorders "hear" and "remember" better, are expedient and practical, protect against libel suits, provide…

  10. Lack of communication and control: experiences of distance caregivers of parents with advanced cancer.

    PubMed

    Mazanec, Polly; Daly, Barbara J; Ferrell, Betty Rolling; Prince-Paul, Maryjo

    2011-05-01

    To explore the new and complex phenomenon of distance caregiving in the advanced cancer population. Qualitative. A large comprehensive cancer center in the midwestern region of the United States. 14 distance caregivers of parents with advanced cancer. Patients with advanced lung, gastrointestinal, and gynecologic malignancies consented to have their distance caregiving adult children contacted to participate in the study. Responses to three open-ended questions guided the tape-recorded telephone interviews with the distance caregivers. Following transcription, content analysis with inductive coding was performed. Two major themes, communication and control, and five subthemes, benefits and burdens of distance caregiving, dealing with uncertainty, direct action through information seeking, protecting, and staying connected, emerged from the data. Distance caregivers experience some of the same stressors that local caregivers of patients with cancer experience. In addition, they have unique psychosocial needs related to the burden of geographic distance. Distance caregivers could benefit from nursing interventions targeted at their unique needs. Innovative interventions using Web-based computer technology for improved communication, as well as supportive care interventions, may be helpful.

  11. The augmentation of heat transfer in a pipe flow using a swirling perforated twisted (SPT) tape insert

    NASA Astrophysics Data System (ADS)

    Ahmad, Shahrokh; Oishe, Sadia Noon; Rahman, Md. Lutfor

    2017-12-01

    The purpose of this research work is to increase the heat transfer coefficient by operating the heat exchangers at smaller revolution per minute. This signifies an achievement of reduction of pressure drop corresponding to less operating cost. This study has used two types of SPT tape insert to observe the various heat transfer coefficient, heat transfer rate and heat transfer augmentation efficiency. One tape was fully twisted and another tape was partially twisted. The shape of the SPT tape creates turbulence effect. The turbulence flow (swirl flow) generated by SPT tape promotes greater mixing and high heat transfer coefficients. An arrangement scheme has been developed for the experimental investigation. For remarking the rate of change of heat transfer, temperature has been measured numerically through the temperature sensors with various flow rates and RPM. The volume flow rate was varied from 10.3448276 LPM to 21.045574 LPM and the rotation of the perforated twisted tape was varied from 50 RPM to 400 RPM. Finally the research study demonstrates the effectiveness of the results of the proposed approaches. It is observed that the suggested method of heat transfer augmentations is much more effective than existing methods, since it results in an increase in heat transfer area and also an increase in the heat transfer coefficient and reduction of cost in the industrial sectors.

  12. Thermally Conductive Tape Based on Carbon Nanotube Arrays

    NASA Technical Reports Server (NTRS)

    Kashani, Ali

    2011-01-01

    To increase contact conductance between two mating surfaces, a conductive tape has been developed by growing dense arrays of carbon nanotubes (CNTs, graphite layers folded into cylinders) on both sides of a thermally conductive metallic foil. When the two mating surfaces are brought into contact with the conductive tape in between, the CNT arrays will adhere to the mating surface. The van der Waals force between the contacting tubes and the mating surface provides adhesion between the two mating surfaces. Even though the thermal contact conductance of a single tube-to-tube contact is small, the tremendous amount of CNTs on the surface leads to a very large overall contact conductance. Interface contact thermal resistance rises from the microroughness and the macroscopic non-planar quality of mating surfaces. When two surfaces come into contact with each other, the actual contact area may be much less than the total area of the surfaces. The real area of contact depends on the load, the surface roughness, and the elastic and inelastic properties of the surface. This issue is even more important at cryogenic temperatures, where materials become hard and brittle and vacuum is used, which prevents any gas conduction through the interstitial region. A typical approach to increase thermal contact conductance is to use thermally conducting epoxies or greases, which are not always compatible with vacuum conditions. In addition, the thermal conductivities of these compounds are often relatively low. The CNTs used in this approach can be metallic or semiconducting, depending on the folding angle and diameter. The electrical resistivity of multiwalled carbon nanotubes (MWCNTs) has been reported. MWCNTs can pass a current density and remain stable at high temperatures in air. The thermal conductivity of a MWCNT at room temperature is measured to be approximately 3,000 W/m-K, which is much larger than that of diamond. At room temperature, the thermal conductance of a 0.3 sq cm

  13. Ankle Spatting Compared to Bracing or Taping during Maximal-Effort Sprint Drills

    PubMed Central

    REUTER, GRANT D; DAHL, ANGELA R; SENCHINA, DAVID S

    2011-01-01

    The purpose of this study was to compare the influences of 4 ankle conditions (no support, bracing, taping, taping + spatting; all in football cleats) during 2 maximal-effort field drills (40-yd dash and 34-yd cutting drill) on perceptions of comfort and stability and performance outcomes. Fourteen young adult males participated. Subjects’ perceptions of comfort and stability were assessed by visual analogue scales after each drill for each ankle condition. Time-to-completion and post-completion heart rate were recorded. For both drills, significant differences in comfort perception were found such that subjects perceived no support as equivocal to bracing but more comfortable than either taping or spatting + taping. Stability results differed by drill. For the dash, significant differences in stability perception were found such that subjects perceived no support as equivocal to bracing but less stable than either taping or spatting + taping. By contrast, for the cutting drill significant differences in stability perception were found such that subjects perceived their ankles as less stable during the no support condition as compared to all 3 other conditions. Generally, bracing was perceived as equivocal to all 3 other conditions for comfort and stability. There were no significant differences in time-to-completion or heart rate for any comparison. Compared to bracing or taping, spatting + taping (a) did not influence performance time in explosive/sprint-type drills, (b) was perceived as equivalent to taping alone in terms of ankle comfort and stability, and (c) was perceived as equivalent to bracing in terms of stability but not comfort. PMID:27478530

  14. Corrosion of metal particle and metal evaporated tapes

    NASA Technical Reports Server (NTRS)

    Speliotis, Dennis E.

    1991-01-01

    Very high coercivity metal particle (MP) and metal evaporated (ME) tapes are being used in 8mm video and digital audio tape applications, and more recently in digital data recording applications. In view of the inherent susceptibility of such media to environmental corrosion, a number of recent studies have addressed their long term stability and archivability. These studies have used an accelerated corrosion test based either on elevated temperature-humidity or polluting gas atmospheres known as Battelle tests. A comparison of the Battelle test results performed at different laboratories reveals a large variation from one location to another, presumably due to incorrect replication of the Battelle condition. Furthermore, when the Battelle tests are performed on enclosed cartridges, it is quite possible that diffusion limits the penetration of the extremely low concentration polluting gaseous species to the inner layers of the tapes during the short time of the accelerated test, whereas in real life these diffusion limitations may not apply. To avoid this uncertainty, the corrosion behavior of commercial 8mm MP and ME tapes when cassettes without their external plastic cases were exposed to 50 deg C and 80 percent RH for 7.5 weeks is investigated.

  15. Flexible storage medium for write-once optical tape

    NASA Technical Reports Server (NTRS)

    Strandjord, Andrew J. G.; Webb, Steven P.; Perettie, Donald J.; Cipriano, Robert A.

    1993-01-01

    A write-once data storage media was developed which is suitable for optical tape applications. The media is manufactured using a continuous film process to deposit a ternary alloy of tin, bismuth, and copper. This laser sensitive layer is sputter deposited onto commercial plastic web as a single-layer thin film. A second layer is sequentially deposited on top of the alloy to enhance the media performance and act as an abrasion resistant hard overcoat. The media was observed to have laser write sensitivities of less than 2.0 njoules/bit, carrier-to-noise levels of greater than 50dB's, modulation depths of approximately 100 percent, read-margins of greater than 35, uniform grain sizes of less than 200 Angstroms, and a media lifetime that exceeds 10 years. Prototype tape media was produced for use in the CREO drive system. The active and overcoat materials are first sputter deposited onto three mil PET film in a single pass through the vacuum coating system, and then converted down into multiple reels of 35mm x 880m tape. One mil PET film was also coated in this manner and then slit and packaged into 3480 tape cartridges.

  16. Precision Lifetime Measurements Using the Recoil Distance Method

    PubMed Central

    Krücken, R.

    2000-01-01

    The recoil distance method (RDM) for the measurements of lifetimes of excited nuclear levels in the range from about 1 ps to 1000 ps is reviewed. The New Yale Plunger Device for RDM experiments is introduced and the Differential Decay Curve Method for their analysis is reviewed. Results from recent RDM experiments on SD bands in the mass-190 region, shears bands in the neutron deficient lead isotopes, and ground state bands in the mass-130 region are presented. Perspectives for the use of RDM measurements in the study of neutron-rich nuclei are discussed. PMID:27551587

  17. Method for braze-joining spirally wound tapes to inner walls of heat exchanger tubes

    DOEpatents

    Garrison, Melton E.

    1984-01-01

    The present invention is directed to a method of fabricating heat exchanger tubes in which twisted tapes are utilized for promoting turbulence and heat transfer. The method of the present invention provides for the brazing of the tapes to the inner walls of the tubes for enhancing heat transfer between the fluid within the conduit and a fluid medium outside of the conduit by conduction through the tape. The braze joint of the present invention is coextensive with the tape over the entire length thereof within the conduit. The practice of the present invention is achieved by placing a filler wire of brazing metal along the tape at a location removed from the side walls and then heating the conduit and tape sufficiently to effect the displacement of the filler metal by wicking to the contact point between the tape and the conduit wall to form a braze joint coextensive with the length of the tape within the conduit. This arrangement provides maximum heat transfer and assures that the tape is in contact with the conduit over the entire common length thereof.

  18. Method for braze-joining spirally wound tapes to inner walls of heat exchanger tubes

    DOEpatents

    Garrison, M.E.

    1982-09-03

    The present invention is directed to a method of fabricating heat exchanger tubes in which twisted tapes are utilized for promoting turbulence and heat transfer. The method of the present invention provides for the brazing of the tapes to the inner walls of the tubes for enhancing heat transfer between the fluid within the conduit and a fluid medium outside of the conduit by conduction through the tape. The braze joint of the present invention is coextensive with the tape over the entire length thereof within the conduit. The practice of the present invention is achieved by placing a filler wire of brazing metal along the tape at a location removed from the side walls and then heating the conduit and tape sufficiently to effect the displacement of the filler metal by wicking to the contact point between the tape and the conduit wall to form a braze joint coextensive with the length of the tape within the conduit. This arrangement provides maximum heat transfer and assures that the tape is in contact with the conduit over the entire common length thereof.

  19. Mobile robot self-localization system using single webcam distance measurement technology in indoor environments.

    PubMed

    Li, I-Hsum; Chen, Ming-Chang; Wang, Wei-Yen; Su, Shun-Feng; Lai, To-Wen

    2014-01-27

    A single-webcam distance measurement technique for indoor robot localization is proposed in this paper. The proposed localization technique uses webcams that are available in an existing surveillance environment. The developed image-based distance measurement system (IBDMS) and parallel lines distance measurement system (PLDMS) have two merits. Firstly, only one webcam is required for estimating the distance. Secondly, the set-up of IBDMS and PLDMS is easy, which only one known-dimension rectangle pattern is needed, i.e., a ground tile. Some common and simple image processing techniques, i.e., background subtraction are used to capture the robot in real time. Thus, for the purposes of indoor robot localization, the proposed method does not need to use expensive high-resolution webcams and complicated pattern recognition methods but just few simple estimating formulas. From the experimental results, the proposed robot localization method is reliable and effective in an indoor environment.

  20. Mobile Robot Self-Localization System Using Single Webcam Distance Measurement Technology in Indoor Environments

    PubMed Central

    Li, I-Hsum; Chen, Ming-Chang; Wang, Wei-Yen; Su, Shun-Feng; Lai, To-Wen

    2014-01-01

    A single-webcam distance measurement technique for indoor robot localization is proposed in this paper. The proposed localization technique uses webcams that are available in an existing surveillance environment. The developed image-based distance measurement system (IBDMS) and parallel lines distance measurement system (PLDMS) have two merits. Firstly, only one webcam is required for estimating the distance. Secondly, the set-up of IBDMS and PLDMS is easy, which only one known-dimension rectangle pattern is needed, i.e., a ground tile. Some common and simple image processing techniques, i.e., background subtraction are used to capture the robot in real time. Thus, for the purposes of indoor robot localization, the proposed method does not need to use expensive high-resolution webcams and complicated pattern recognition methods but just few simple estimating formulas. From the experimental results, the proposed robot localization method is reliable and effective in an indoor environment. PMID:24473282

  1. Accuracy enhanced distance measurement system using double-sideband modulated frequency scanning interferometry

    NASA Astrophysics Data System (ADS)

    Chen, Xilun; Wang, Xiangchuan; Pan, Shilong

    2017-03-01

    An implementation of a distance measurement system using double-sideband with suppressed carrier modulation (DSB-SC) frequency scanning interferometry is proposed to reduce the variations in the optical path and improve the measurement accuracy. In this proposed system, the electro-optic DSB-SC is used to create dual-swept signals with opposite scanning directions. For each swept signal, the relative distance between the reference arm and the measuring arm is determined by the beat frequency of signals from two arms. By multiplying both beat signals, measurement errors caused by variations in the optical path can be greatly reduced. As an experimental demonstration, a vibration was introduced in the optical path length. The experimental results show that the variations can be suppressed for over 19.9 dB.

  2. Textured substrate tape and devices thereof

    DOEpatents

    Goyal, Amit

    2006-08-08

    A method for forming a sharply biaxially textured substrate, such as a single crystal substrate, includes the steps of providing a deformed metal substrate, followed by heating above the secondary recrystallization temperature of the deformed substrate, and controlling the secondary recrystallization texture by either using thermal gradients and/or seeding. The seed is selected to shave a stable texture below a predetermined temperature. The sharply biaxially textured substrate can be formed as a tape having a length of 1 km, or more. Epitaxial articles can be formed from the tapes to include an epitaxial electromagnetically active layer. The electromagnetically active layer can be a superconducting layer.

  3. String and Sticky Tape Experiments.

    ERIC Educational Resources Information Center

    Edge, R. D., Ed.

    1979-01-01

    Explains how to demonstrate the fundamentals of one dimensional kinematics such as Newton's third law of motion, and collision between bodies, using simple materials of marbles, strings, sticky tape, drinking straws, and rubber bands. (GA)

  4. Kinesiology taping as an adjunct for pain management in cancer?

    PubMed

    Banerjee, Gourav; Rebanks, Jonathan; Briggs, Michelle; Johnson, Mark I

    2016-07-14

    We present the case of a 46-year-old woman who developed severe pain described as 'tearing' and 'searing' in the left side of the mid-trapezius region near the thoracic 8 vertebra (T8). The patient had undergone surgery for T8 fracture which had resulted from metastasis (secondary breast cancer). A community nurse referred the patient for physiotherapy assessment and treatment for her musculoskeletal pain and related symptoms that had affected her mobility and functional activities. The patient was treated with soft tissue therapy with the addition of kinesiology taping on follow-up visits. Kinesiology tape was applied over her left side trapezius region and left shoulder. The patient reported significant reductions in pain severity and felt greater control and stability over her left shoulder region, which resulted in better function and overall quality of life measures. She did not report any adverse effects. 2016 BMJ Publishing Group Ltd.

  5. THE EFFECTS OF VARIED TENSIONS OF KINESIOLOGY TAPING ON QUADRICEPS STRENGTH AND LOWER LIMB FUNCTION

    PubMed Central

    Franco, Yuri Rafael dos Santos; Nannini, Stella Bispo; Nakaoka, Gustavo Bezerra; dos Reis, Amir Curcio; Bryk, Flavio Fernandes

    2017-01-01

    Background Kinesiology Taping (KT) may promote changes in muscle strength and motor performance, topics of great interest in the sports-medicine sciences. These characteristics are purported to be associated with the tension generated by the KT on the skin. However, the most suitable tension for the attainment of these strength and performance effects has not yet been confirmed. Hypothesis/Purpose The purpose of the present study was to analyze the effects of different tensions of KT on the isometric contraction of the quadriceps and lower limb function of healthy individuals over a period of seven days. Study Design Blind, randomized, clinical trial. Methods One hundred and thirty healthy individuals were distributed into the following five groups: control (without KT); KT0 (KT without tension); KT50; KT75 and KT100 (approximately 50%, 75% and 100% tension applied to the tape, respectively). Assessments of isometric quadriceps strength were conducted using a hand held dynamometer. Lower limb function was assessed through Single Hop Test for Distance, with five measurement periods: baseline; immediately after KT application; three days after KT; five days after KT; and 72h after KT removal (follow-up). Results There were no statistically significant differences (p > 0.05) at any of the studied periods on participants’ quadriceps strength nor in the function of the lower dominant limb, based on comparisons between the control group and the experimental groups. Conclusion KT applied with different tensions did not produce modulations, in short or long-term, on quadriceps’ strength or lower limb function of healthy individuals. Therefore, this type of KT application, when seeking these objectives, should be reconsidered. Level of Evidence 1b PMID:28217419

  6. Helical tape forming device

    NASA Technical Reports Server (NTRS)

    Bush, J. E.; Cole, P. T.

    1969-01-01

    Using a device that is not limited to a minimum thickness or width-to-thickness ratio, a very thin metal tape or ribbon is formed into a continuous flat wound helical coil. The device imparts the desired circular shape by squeeze rolling it with an unequal force across its width.

  7. Torsional Properties of TiNi Shape Memory Alloy Tape for Rotary Actuator

    NASA Astrophysics Data System (ADS)

    Takeda, K.; Tobushi, H.; Mitsui, K.; Nishimura, Y.; Miyamoto, K.

    2012-12-01

    In order to develop novel shape memory actuators, the torsional deformation of a shape memory alloy (SMA) tape and the actuator models driven by the tape were investigated. The results obtained can be summarized as follows. In the SMA tape subjected to torsion, the martensitic transformation appears along both edges of the tape due to elongation of these elements and grows to the central part. The fatigue life in both the pulsating torsion and alternating torsion is expressed by the unified relationship of the dissipated work in each cycle. Based on an opening and closing door model and a solar-powered active blind model, the two-way rotary driving actuator with a small and simple mechanism can be developed by using torsion of the SMA tape.

  8. Problems with small area surveys: lensing covariance of supernova distance measurements.

    PubMed

    Cooray, Asantha; Huterer, Dragan; Holz, Daniel E

    2006-01-20

    While luminosity distances from type Ia supernovae (SNe) are a powerful probe of cosmology, the accuracy with which these distances can be measured is limited by cosmic magnification due to gravitational lensing by the intervening large-scale structure. Spatial clustering of foreground mass leads to correlated errors in SNe distances. By including the full covariance matrix of SNe, we show that future wide-field surveys will remain largely unaffected by lensing correlations. However, "pencil beam" surveys, and those with narrow (but possibly long) fields of view, can be strongly affected. For a survey with 30 arcmin mean separation between SNe, lensing covariance leads to a approximately 45% increase in the expected errors in dark energy parameters.

  9. Realization and testing of a deployable space telescope based on tape springs

    NASA Astrophysics Data System (ADS)

    Lei, Wang; Li, Chuang; Zhong, Peifeng; Chong, Yaqin; Jing, Nan

    2017-08-01

    For its compact size and light weight, space telescope with deployable support structure for its secondary mirror is very suitable as an optical payload for a nanosatellite or a cubesat. Firstly the realization of a prototype deployable space telescope based on tape springs is introduced in this paper. The deployable telescope is composed of primary mirror assembly, secondary mirror assembly, 6 foldable tape springs to support the secondary mirror assembly, deployable baffle, aft optic components, and a set of lock-released devices based on shape memory alloy, etc. Then the deployment errors of the secondary mirror are measured with three-coordinate measuring machine to examine the alignment accuracy between the primary mirror and the deployed secondary mirror. Finally modal identification is completed for the telescope in deployment state to investigate its dynamic behavior with impact hammer testing. The results of the experimental modal identification agree with those from finite element analysis well.

  10. Application of Kinesio Taping method for newborn swallowing difficultly

    PubMed Central

    Lin, Chien-Lin; Wu, Wei-Ting; Chang, Ke-Vin; Lin, Hong-Yi; Chou, Li-Wei

    2016-01-01

    Abstract Background: Preterm infants are at an increased risk of sucking problems, swallowing difficulty, and poor nourishment. During the neonatal period, the neurobehavioral organization of a preterm baby is poor compared with that of appropriate gestational age infants. Kinesio Taping has been widely used for edema control, joint protection, and proprioception training. With the help of augmentation of the sensory input for muscle facilitation and inhibition through tapping, the coordination of the target muscle groups can be improved. Until now, no research is available on the use of Kinesio Taping for the swallowing difficulty of infant. Methods: We reported a preterm infant suffering from brain edema at birth and swallowing difficultly until 40 weeks. The swallowing reflex was delayed. Moreover, lip closure and rooting reflex combined with the dysfunction grade of jaw movement were poor. We performed KT methods on the baby under the theory of the direction of the tape for facilitate or inhibit the muscle. Result: After the Kinesio Taping treatment, the sucking function was improved with good lip closure.One week later, the baby was discharged without the use of an oral gastric tube. Conclusion: Kinesio Taping contributed significantly to the improvement of impaired sucking and swallowing and could be implemented as a regular rehabilitative approach for infants suffering from these difficulties. PMID:27495080

  11. Absolute distance measurement with correction of air refractive index by using two-color dispersive interferometry.

    PubMed

    Wu, Hanzhong; Zhang, Fumin; Liu, Tingyang; Li, Jianshuang; Qu, Xinghua

    2016-10-17

    Two-color interferometry is powerful for the correction of the air refractive index especially in the turbulent air over long distance, since the empirical equations could introduce considerable measurement uncertainty if the environmental parameters cannot be measured with sufficient precision. In this paper, we demonstrate a method for absolute distance measurement with high-accuracy correction of air refractive index using two-color dispersive interferometry. The distances corresponding to the two wavelengths can be measured via the spectrograms captured by a CCD camera pair in real time. In the long-term experiment of the correction of air refractive index, the experimental results show a standard deviation of 3.3 × 10-8 for 12-h continuous measurement without the precise knowledge of the environmental conditions, while the variation of the air refractive index is about 2 × 10-6. In the case of absolute distance measurement, the comparison with the fringe counting interferometer shows an agreement within 2.5 μm in 12 m range.

  12. Performance of preformed plastic tapes.

    DOT National Transportation Integrated Search

    1982-01-01

    This study was initiated to investigate the overall performance of preformed pavement marking tapes with respect to their appearance, durability, and night visibility, and to recommend criteria for the selection of such materials based on their perfo...

  13. Double-sideband frequency scanning interferometry for long-distance dynamic absolute measurement

    NASA Astrophysics Data System (ADS)

    Mo, Di; Wang, Ran; Li, Guang-zuo; Wang, Ning; Zhang, Ke-shu; Wu, Yi-rong

    2017-11-01

    Absolute distance measurements can be achieved by frequency scanning interferometry which uses a tunable laser. The main drawback of this method is that it is extremely sensitive to the movement of targets. In addition, since this method is limited to the linearity of frequency scanning, it is commonly used for close measurements within tens of meters. In order to solve these problems, a double-sideband frequency scanning interferometry system is presented in the paper. It generates two opposite frequency scanning signals through a fixed frequency laser and a Mach-Zehnder modulator. And the system distinguishes the two interference fringe patterns corresponding to the two signals by IQ demodulation (i.e., quadrature detection) of the echo. According to the principle of double-sideband modulation, the two signals have the same characteristics. Therefore, the error caused by the target movement can be effectively eliminated, which is similar to dual-laser frequency scanned interferometry. In addition, this method avoids the contradiction between laser frequency stability and swept performance. The system can be applied to measure the distance of the order of kilometers, which profits from the good linearity of frequency scanning. In the experiment, a precision about 3 μm was achieved for a kilometer-level distance.

  14. One-step Tape Casting of Composites via Slurry on Fiber

    NASA Technical Reports Server (NTRS)

    deGroh, Henry C., III

    2001-01-01

    A process by which metal matrix composites can be made was presented. The process involves putting a powder slurry on fibers to make a precursor green tape. These green tapes are cut, stacked and hot pressed to form the fully dense composite. A computer program was presented which enables complete quantification and control of the process. Once some easily obtained properties of the slurry and its behavior are determined (such as the shrinkage from the wet to green state, and the density of the green tape) modification of the fiber spacing and blade height give the maker precise control of fiber volume fraction, and fiber architecture in the composite. The process was shown to be accurate and flexible through the production of a wide variety of volume fraction fiber composites made from a wide variety of fibers and powders. The most time consuming step of the tape casting process (other than hot pressing) was winding the fiber on the drum. The tape casting techniques developed resulted in high quality metal matrix composites, with ultimate tensile strength in the range of 215 ksi (1477 MPa), a strain at failure of 1.15 percent, and in fatigue at room temperature 0 to 120 ksi, n = 0.3 Hz, a 4-ply Ti-24Al-11Nb/SCS-6, 32 vol% fiber tape cast composite lasted 202,205 cycles with a maximum strain on the 100th cycle of 0.43 percent.

  15. Measurement of a cosmographic distance ratio with galaxy and cosmic microwave background lensing

    DOE PAGES

    Miyatake, Hironao; Madhavacheril, Mathew S.; Sehgal, Neelima; ...

    2017-04-17

    We measure the gravitational lensing shear signal around dark matter halos hosting constant mass galaxies using light sources at z~1 (background galaxies) and at the surface of last scattering at z~1100 (the cosmic microwave background). The galaxy shear measurement uses data from the CFHTLenS survey, and the microwave background shear measurement uses data from the Planck satellite. The ratio of shears from these cross-correlations provides a purely geometric distance measurement across the longest possible cosmological lever arm. This is because the matter distribution around the halos, including uncertainties in galaxy bias and systematic errors such as miscentering, cancels in themore » ratio for halos in thin redshift slices. We measure this distance ratio in three different redshift slices of the constant mass (CMASS) sample and combine them to obtain a 17% measurement of the distance ratio, r = 0.390 +0.070 –0.062, at an effective redshift of z = 0.53. As a result, this is consistent with the predicted ratio from the Planck best-fit cold dark matter model with a cosmological constant cosmology of r = 0.419.« less

  16. Testing of machine wound second generation HTS tape Vacuum Pressure Impregnated coils

    NASA Astrophysics Data System (ADS)

    Swaffield, D.; Lewis, C.; Eugene, J.; Ingles, M.; Peach, D.

    2014-05-01

    Delamination of second generation (2G) High Temperature Superconducting (HTS) tapes has previously been reported when using resin based insulation systems for wound coils. One proposed root cause is the differential thermal contraction between the coil former and the resin encapsulated coil turns resulting in the tape c-axis tensile stress being exceeded. Importantly, delamination results in unacceptable degradation of the superconductor critical current level. To mitigate the delamination risk and prove winding, jointing and Vacuum Pressure Impregnation (VPI) processes in the production of coils for superconducting rotating machines at GE Power Conversion two scaled trial coils have been wound and extensively tested. The coils are wound from 12mm wide 2G HTS tape supplied by AMSC onto stainless steel 'racetrack' coil formers. The coils are wound in two layers which include both in-line and layer-layer joints subject to in-process test. The resin insulation system chosen is VPI and oven cured. Tests included; insulation resistance, repeat quench and recovery of the superconductor, heat runs and measurement of n-value, before and after multiple thermal cycling between ambient and 35 Kelvin. No degradation of coil performance is evidenced.

  17. Effect of patellar strap and sports tape on pain in patellar tendinopathy: A randomized controlled trial.

    PubMed

    de Vries, A; Zwerver, J; Diercks, R; Tak, I; van Berkel, S; van Cingel, R; van der Worp, H; van den Akker-Scheek, I

    2016-10-01

    Numerous athletes with patellar tendinopathy (PT) use a patellar strap or sports tape during sports. This study's aim was to investigate the short-term effect of these orthoses on patellar tendon pain. Participants performed the single-leg decline squat, vertical jump test, and triple-hop test under four different conditions (patellar strap, sports tape, placebo, and control). Subsequently, participants practiced sports as usual for 2 weeks; during 1 week, they were assigned to one of the four conditions. Pain was measured with the visual analog scale (VAS). In total, 97 athletes with PT [61% male, age 27.0 (SD8.1), VISA-P 58.5 (SD12.7)] were analyzed. On the single-leg decline squat, the VAS pain score reduced significantly in the patellar strap (14 mm, P = 0.04) and the sports tape condition (13 mm, P = 0.04), compared with control, but not placebo. A significant decrease in VAS pain during sports was found in the sports tape (7 mm, P = 0.04) and placebo group (6 mm, P = 0.04). The VAS pain score two hours after sports decreased significantly in the patellar strap, sports tape and placebo group (8-mm, P < 0.001, 10 mm, P = 0.001 and 7 mm, P = 0.03, respectively). This study's findings indicate that an orthosis (including placebo tape) during sports can reduce pain in PT patients in the short term. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Transaction aware tape-infrastructure monitoring

    NASA Astrophysics Data System (ADS)

    Nikolaidis, Fotios; Kruse, Daniele Francesco

    2014-06-01

    Administrating a large scale, multi protocol, hierarchical tape infrastructure like the CERN Advanced STORage manager (CASTOR)[2], which stores now 100 PB (with an increasing step of 25 PB per year), requires an adequate monitoring system for quick spotting of malfunctions, easier debugging and on demand report generation. The main challenges for such system are: to cope with CASTOR's log format diversity and its information scattered among several log files, the need for long term information archival, the strict reliability requirements and the group based GUI visualization. For this purpose, we have designed, developed and deployed a centralized system consisting of four independent layers: the Log Transfer layer for collecting log lines from all tape servers to a single aggregation server, the Data Mining layer for combining log data into transaction context, the Storage layer for archiving the resulting transactions and finally the Web UI layer for accessing the information. Having flexibility, extensibility and maintainability in mind, each layer is designed to work as a message broker for the next layer, providing a clean and generic interface while ensuring consistency, redundancy and ultimately fault tolerance. This system unifies information previously dispersed over several monitoring tools into a single user interface, using Splunk, which also allows us to provide information visualization based on access control lists (ACL). Since its deployment, it has been successfully used by CASTOR tape operators for quick overview of transactions, performance evaluation, malfunction detection and from managers for report generation.

  19. Digital terrain tapes: user guide

    USGS Publications Warehouse

    ,

    1980-01-01

    DMATC's digital terrain tapes are a by-product of the agency's efforts to streamline the production of raised-relief maps. In the early 1960's DMATC developed the Digital Graphics Recorder (DGR) system that introduced new digitizing techniques and processing methods into the field of three-dimensional mapping. The DGR system consisted of an automatic digitizing table and a computer system that recorded a grid of terrain elevations from traces of the contour lines on standard topographic maps. A sequence of computer accuracy checks was performed and then the elevations of grid points not intersected by contour lines were interpolated. The DGR system produced computer magnetic tapes which controlled the carving of plaster forms used to mold raised-relief maps. It was realized almost immediately that this relatively simple tool for carving plaster molds had enormous potential for storing, manipulating, and selectively displaying (either graphically or numerically) a vast number of terrain elevations. As the demand for the digital terrain tapes increased, DMATC began developing increasingly advanced digitizing systems and now operates the Digital Topographic Data Collection System (DTDCS). With DTDCS, two types of data elevations as contour lines and points, and stream and ridge lines are sorted, matched, and resorted to obtain a grid of elevation values for every 0.01 inch on each map (approximately 200 feet on the ground). Undefined points on the grid are found by either linear or or planar interpolation.

  20. Accuracy of the Broselow Tape in South Sudan, "The Hungriest Place on Earth".

    PubMed

    Clark, Melissa C; Lewis, Roger J; Fleischman, Ross J; Ogunniyi, Adedamola A; Patel, Dipesh S; Donaldson, Ross I

    2016-01-01

    The Broselow tape is a length-based tool used for the rapid estimation of pediatric weight and was developed to reduce dosage-related errors during emergencies. This study seeks to assess the accuracy of the Broselow tape and age-based formulas in predicting weights of South Sudanese children of varying nutritional status. This was a retrospective, cross-sectional study using data from existing acute malnutrition screening programs for children less than 5 years of age in South Sudan. Using anthropometric measurements, actual weights were compared with estimated weights from the Broselow tape and three age-based formulas. Mid-upper arm circumference was used to determine if each child was malnourished. Broselow accuracy was assessed by the percentage of measured weights falling into the same color zone as the predicted weight. For each method, accuracy was assessed by mean percentage error and percentage of predicted weights falling within 10% of actual weight. All data were analyzed by nutritional status subgroup. Only 10.7% of malnourished and 26.6% of nonmalnourished children had their actual weight fall within the Broselow color zone corresponding to their length. The Broselow method overestimated weight by a mean of 26.6% in malnourished children and 16.6% in nonmalnourished children (p < 0.001). Age-based formulas also overestimated weight, with mean errors ranging from 16.2% over actual weight (Advanced Pediatric Life Support in nonmalnourished children) to 70.9% over actual (Best Guess in severely malnourished children). The Broselow tape and age-based formulas selected for comparison were all markedly inaccurate in both the nonmalnourished and the malnourished populations studied, worsening with increasing malnourishment. Additional studies should explore appropriate methods of weight and dosage estimation for populations of low- and low-to-middle-income countries and regions with a high prevalence of malnutrition. © 2015 by the Society for Academic

  1. High-throughput DNA extraction of forensic adhesive tapes.

    PubMed

    Forsberg, Christina; Jansson, Linda; Ansell, Ricky; Hedman, Johannes

    2016-09-01

    Tape-lifting has since its introduction in the early 2000's become a well-established sampling method in forensic DNA analysis. Sampling is quick and straightforward while the following DNA extraction is more challenging due to the "stickiness", rigidity and size of the tape. We have developed, validated and implemented a simple and efficient direct lysis DNA extraction protocol for adhesive tapes that requires limited manual labour. The method uses Chelex beads and is applied with SceneSafe FAST tape. This direct lysis protocol provided higher mean DNA yields than PrepFiler Express BTA on Automate Express, although the differences were not significant when using clothes worn in a controlled fashion as reference material (p=0.13 and p=0.34 for T-shirts and button-down shirts, respectively). Through in-house validation we show that the method is fit-for-purpose for application in casework, as it provides high DNA yields and amplifiability, as well as good reproducibility and DNA extract stability. After implementation in casework, the proportion of extracts with DNA concentrations above 0.01ng/μL increased from 71% to 76%. Apart from providing higher DNA yields compared with the previous method, the introduction of the developed direct lysis protocol also reduced the amount of manual labour by half and doubled the potential throughput for tapes at the laboratory. Generally, simplified manual protocols can serve as a cost-effective alternative to sophisticated automation solutions when the aim is to enable high-throughput DNA extraction of complex crime scene samples. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  2. Collegiate Football Players' Ankle Range of Motion and Dynamic Balance in Braced and Self-Adherent-Taped Conditions.

    PubMed

    Willeford, Kristin; Stanek, Justin M; McLoda, Todd A

    2018-01-01

      Ankle sprains are one of the most common injuries in the physically active population. Previous researchers have shown that supporting the ankle with taping or bracing is effective in preventing ankle sprains. However, no authors have compared the effects of self-adherent tape and lace-up ankle braces on ankle range of motion (ROM) and dynamic balance in collegiate football players.   To examine the effectiveness of self-adherent tape and lace-up ankle braces in reducing ankle ROM and improving dynamic balance before and after a typical collegiate football practice.   Crossover study.   Collegiate athletic training room.   Twenty-nine National Collegiate Athletic Association Division I football athletes (age = 19.2 ± 1.14 years, height = 187.52 ± 20.54 cm, mass = 106.44 ± 20.54 kg).   Each participant wore each prophylactic ankle support during a single practice, self-adherent tape on 1 leg and lace-up ankle brace on the other. Range of motion and dynamic balance were assessed 3 times for each leg throughout the testing session (baseline, prepractice, postpractice).   Ankle ROM for inversion, eversion, dorsiflexion, and plantar flexion were measured at baseline, immediately after donning the brace or tape, and immediately after a collegiate practice. The Y-Balance Test was used to assess dynamic balance at these same time points.   Both interventions were effective in reducing ROM in all directions compared with baseline; however, dynamic balance did not differ between the tape and brace conditions.   Both the self-adherent tape and lace-up ankle brace provided equal ROM restriction before and after exercise, with no change in dynamic balance.

  3. Tape-recorded Lectures With Slide Synchronization

    ERIC Educational Resources Information Center

    Goodhue, D.

    1969-01-01

    Describes "Taped Explanation Slide Synchronization" programs used for individual study or group showing in college zoology. Discusses preparation of programs, class organization, equipment, and costs. (EB)

  4. Irradiation response of commercial, high-Tc superconducting tapes: Electromagnetic transport properties

    DOE PAGES

    Gapud, A. A.; Greenwood, N. T.; Alexander, J. A.; ...

    2015-07-01

    Effects of low dose irradiation on the electrical transport current properties of commercially available high-temperature superconducting, coated-conductor tapes were investigated, in view of potential applications in the irradiative environment of fusion reactors. Three different tapes, each with unique as-grown flux-pinning structures, were irradiated with Au and Ni ions at energies that provide a range of damage effects, with accumulated damage levels near that expected for conductors in a fusion reactor environment. Measurements using transport current determined the pre- and post-irradiation resistivity, critical current density, and pinning force density, yielding critical temperatures, irreversibility lines, and inferred vortex creep rates. Results showmore » that at the irradiation damage levels tested, any detriment to as-grown pre-irradiation properties is modest; indeed in one case already-superior pinning forces are enhanced, leading to higher critical currents.« less

  5. [A New Distance Metric between Different Stellar Spectra: the Residual Distribution Distance].

    PubMed

    Liu, Jie; Pan, Jing-chang; Luo, A-li; Wei, Peng; Liu, Meng

    2015-12-01

    Distance metric is an important issue for the spectroscopic survey data processing, which defines a calculation method of the distance between two different spectra. Based on this, the classification, clustering, parameter measurement and outlier data mining of spectral data can be carried out. Therefore, the distance measurement method has some effect on the performance of the classification, clustering, parameter measurement and outlier data mining. With the development of large-scale stellar spectral sky surveys, how to define more efficient distance metric on stellar spectra has become a very important issue in the spectral data processing. Based on this problem and fully considering of the characteristics and data features of the stellar spectra, a new distance measurement method of stellar spectra named Residual Distribution Distance is proposed. While using this method to measure the distance, the two spectra are firstly scaled and then the standard deviation of the residual is used the distance. Different from the traditional distance metric calculation methods of stellar spectra, when used to calculate the distance between stellar spectra, this method normalize the two spectra to the same scale, and then calculate the residual corresponding to the same wavelength, and the standard error of the residual spectrum is used as the distance measure. The distance measurement method can be used for stellar classification, clustering and stellar atmospheric physical parameters measurement and so on. This paper takes stellar subcategory classification as an example to test the distance measure method. The results show that the distance defined by the proposed method is more effective to describe the gap between different types of spectra in the classification than other methods, which can be well applied in other related applications. At the same time, this paper also studies the effect of the signal to noise ratio (SNR) on the performance of the proposed method

  6. Measuring the Dust Grains and Distance to X Persei Via Its X-ray Halo

    NASA Astrophysics Data System (ADS)

    Smith, Randall

    2006-09-01

    We propose to observe the X-ray halo of the high mass X-ray binary pulsar X Per to measure interstellar dust grains along the line of sight (LOS) and to determine the distance to X Per. The X-ray halo is formed by scattering from grains along the LOS, which for X Per appear to be concentrated in one molecular cloud. Unlike many other X-ray halo observations, this low-absorption high-latitude sightline is well-characterized from absorption spectroscopy done with HST, Copernicus, and FUSE. This halo observation will measure the distance to the cloud and the dust size distribution in it. We will also be able to determine the distance to X Per by measuring the time delayed pulses in the X-ray halo.

  7. The effects of kinesio taping on the color intensity of superficial skin hematomas: A pilot study.

    PubMed

    Vercelli, Stefano; Colombo, Claudio; Tolosa, Francesca; Moriondo, Andrea; Bravini, Elisabetta; Ferriero, Giorgio; Francesco, Sartorio

    2017-01-01

    To analyze the effects of kinesio taping (KT) -applied with three different strains that induced or not the formation of skin creases (called convolutions)- on color intensity of post-surgical superficial hematomas. Single-blind paired study. Rehabilitation clinic. A convenience sample of 13 inpatients with post-surgical superficial hematomas. The tape was applied for 24 consecutive hours. Three tails of KT were randomly applied with different degrees of strain: none (SN); light (SL); and full longitudinal stretch (SF). We expected to obtain correct formation of convolutions with SL, some convolutions with SN, and no convolutions with SF. The change in color intensity of hematomas, measured by means of polar coordinates CIE L*a*b* using a validated and standardized digital images system. Applying KT to hematomas did not significantly change the color intensity in the central area under the tape (p > 0.05). There was a significant treatment effect (p < 0.05) under the edges of the tape, independently of the formation of convolutions (p > 0.05). The changes observed along the edges of the tape could be related to the formation of a pressure gradient between the KT and the adjacent area, but were not dependent on the formation of skin convolutions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Kinesio taping in young healthy subjects does not affect postural reflex reactions and anticipatory postural adjustments of the trunk: a pilot study.

    PubMed

    Voglar, Matej; Sarabon, Nejc

    2014-09-01

    Therapeutic Kinesio Taping method is used for treatment of various musculo-skeletal conditions. Kinesio Taping might have some small clinically important beneficial effects on range of motion and strength but findings about the effects on proprioception and muscle activation are inconsistent. The aim of this study was to test if Kinesio Taping influences anticipatory postural adjustments and postural reflex reactions. To test the hypothesis twelve healthy young participants were recruited in randomized, participants blinded, placebo controlled cross-over study. In the experimental condition the tape was applied over the paravertebral muscles and in placebo condition sham application of the tape was done transversally over the lumbar region. Timing of anticipatory postural adjustments to fast voluntary arms movement and postural reflex reactions to sudden loading over the hands were measured by means of superficial electromyography before and one hour after each tape application. Results showed no significant differences between Kinesio Taping and placebo taping conditions for any of the analyzed muscles in anticipatory postural adaptations (F1,11 < 0.23, p > 0.64, η2 < 0.04) or postural reflex reactions (F1,11 < 4.16, p > 0.07, η(2) < 0.49). Anticipatory postural adjustments of erector spinae and multifidus muscles were initiated significantly earlier after application of taping (regardless of technique) compared to pre-taping (F1,11 = 5.02, p = 0.046, η(2) = 0.31 and F1,11 = 6.18, p = 0.030, η(2) = 0.36 for erector spinae and multifidus, respectively). Taping application over lumbar region has potential beneficial effects on timing of anticipatory postural adjustments regardless of application technique but no effect on postural reflex reactions in young pain free participants. Further research in patients with low back pain would be encouraged. Key PointsApplication of Kinesio Taping does not affect postural reflex reactions in young healthy population

  9. Research on resistance characteristics of YBCO tape under short-time DC large current impact

    NASA Astrophysics Data System (ADS)

    Zhang, Zhifeng; Yang, Jiabin; Qiu, Qingquan; Zhang, Guomin; Lin, Liangzhen

    2017-06-01

    Research of the resistance characteristics of YBCO tape under short-time DC large current impact is the foundation of the developing DC superconducting fault current limiter (SFCL) for voltage source converter-based high voltage direct current system (VSC-HVDC), which is one of the valid approaches to solve the problems of renewable energy integration. SFCL can limit DC short-circuit and enhance the interrupting capabilities of DC circuit breakers. In this paper, under short-time DC large current impacts, the resistance features of naked tape of YBCO tape are studied to find the resistance - temperature change rule and the maximum impact current. The influence of insulation for the resistance - temperature characteristics of YBCO tape is studied by comparison tests with naked tape and insulating tape in 77 K. The influence of operating temperature on the tape is also studied under subcooled liquid nitrogen condition. For the current impact security of YBCO tape, the critical current degradation and top temperature are analyzed and worked as judgment standards. The testing results is helpful for in developing SFCL in VSC-HVDC.

  10. Synchrotron x-ray scattering measurements of bulk structural properties in superconducting (Bi,Pb){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10}{endash}Ag tapes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thurston, T.R.; Wildgruber, U.; Jisrawi, N.

    The structural properties of superconducting (Bi,Pb){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10}{endash}Ag (2223) tapes have been measured using synchrotron x-ray scattering techniques. The x-ray photon energy was tuned just below the silver {ital K} absorption edge so the penetration depth was large, which allowed the measurements to be performed in a transmission geometry without removing the silver cladding. Analysis of the peaks in 2{theta} scans indicates that residual (Bi,Pb){sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8} (2212) superconductor starting material is present in all samples studied. The amount of 2212 varied widely among the tapes, and was not homogeneous along the length of eachmore » individual tape. Residual 2212 content increased near the ends of most samples, suggesting that 2223 phase development is sensitive to whether the superconducting material is encased in silver or not. The bulk {ital c}-axis alignment was measured in {approximately}100 mono- and multifilament samples, and correlations between {ital c}-axis alignment and current carrying capacity at 77 K were found. Multifilament samples generally had better alignment than monofilament samples. The {ital c}-axis alignment along the length of the tapes was uniform, and the superconducting material within {approximately}1 {mu}m of the Ag was better textured than the bulk of the sample. Intermediate pressings were directly shown to have an adverse affect on {ital c}-axis alignment. Finally, the evolution of texture and phase development was examined in a series of samples annealed for varying times. The 2212 starting material acquired the final {ital c}-axis alignment state after brief heating times, and only after much longer heating times did the 2212 transform into the 2223 phase. These results and their implications for improving processing procedures are discussed. {copyright} {ital 1996 American Institute of Physics.}« less

  11. Occupational exposure to asbestos in the drywall taping process.

    PubMed

    Verma, D K; Middleton, C G

    1980-04-01

    Studies of airborne asbestos fiber concentrations associated with various operations of the drywall taping process have been undertaken in the province of Alberta, Canada. The results show that mixing, sanding and sweeping created high levels of airborne asbestos dust. The measured concentrations were frequently in excess of occupational health standards. Sanding in particular was assessed the most hazardous operation. The results are discussed in light of present and proposed Occupational Health Standards, and in terms of its implications for other workers, household contacts, and consumer's risk. Measures to reduce and control the health hazards associated with the process are described.

  12. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 3 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 6 and 7. The activities from other flight days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). Flight day 6 features a very complicated EVA (extravehicular activity) to service the HST (Hubble Space Telescope). Astronauts Grunsfeld and Linnehan replace the HST's power control unit, disconnecting and reconnecting 36 tiny connectors. The procedure includes the HST's first ever power down. The cleanup of spilled water from the coollant system in Grunsfeld's suit is shown. The pistol grip tool, and two other space tools are also shown. On flight day 7, Newman and Massimino conduct an EVA. They replace the HST's FOC (Faint Object Camera) with the ACS (Advanced Camera for Surveys). The video ends with crew members playing in the shuttle's cabin with a model of the HST.

  13. The ISEE-3 ULEWAT: Flux tape description and heavy ion fluxes 1978-1984. [plasma diagnostics

    NASA Technical Reports Server (NTRS)

    Mason, G. M.; Klecker, B.

    1985-01-01

    The ISEE ULEWAT FLUX tapes contain ULEWAT and ISEE pool tape data summarized over relatively long time intervals (1hr) in order to compact the data set into an easily usable size. (Roughly 3 years of data fit onto one 1600 BPI 9-track magnetic tape). In making the tapes, corrections were made to the ULEWAT basic data tapes in order to, remove rate spikes and account for changes in instrument response so that to a large extent instrument fluxes can be calculated easily from the FLUX tapes without further consideration of instrument performance.

  14. ICI optical data storage tape: An archival mass storage media

    NASA Technical Reports Server (NTRS)

    Ruddick, Andrew J.

    1993-01-01

    At the 1991 Conference on Mass Storage Systems and Technologies, ICI Imagedata presented a paper which introduced ICI Optical Data Storage Tape. This paper placed specific emphasis on the media characteristics and initial data was presented which illustrated the archival stability of the media. More exhaustive analysis that was carried out on the chemical stability of the media is covered. Equally important, it also addresses archive management issues associated with, for example, the benefits of reduced rewind requirements to accommodate tape relaxation effects that result from careful tribology control in ICI Optical Tape media. ICI Optical Tape media was designed to meet the most demanding requirements of archival mass storage. It is envisaged that the volumetric data capacity, long term stability and low maintenance characteristics demonstrated will have major benefits in increasing reliability and reducing the costs associated with archival storage of large data volumes.

  15. Discoloration of polyvinyl chloride (PVC) tape as a proxy for water-table depth in peatlands: validation and assessment of seasonal variability

    USGS Publications Warehouse

    Booth, Robert K.; Hotchkiss, Sara C.; Wilcox, Douglas A.

    2005-01-01

    Summary: 1. Discoloration of polyvinyl chloride (PVC) tape has been used in peatland ecological and hydrological studies as an inexpensive way to monitor changes in water-table depth and reducing conditions. 2. We investigated the relationship between depth of PVC tape discoloration and measured water-table depth at monthly time steps during the growing season within nine kettle peatlands of northern Wisconsin. Our specific objectives were to: (1) determine if PVC discoloration is an accurate method of inferring water-table depth in Sphagnum-dominated kettle peatlands of the region; (2) assess seasonal variability in the accuracy of the method; and (3) determine if systematic differences in accuracy occurred among microhabitats, PVC tape colour and peatlands. 3. Our results indicated that PVC tape discoloration can be used to describe gradients of water-table depth in kettle peatlands. However, accuracy differed among the peatlands studied, and was systematically biased in early spring and late summer/autumn. Regardless of the month when the tape was installed, the highest elevations of PVC tape discoloration showed the strongest correlation with midsummer (around July) water-table depth and average water-table depth during the growing season. 4. The PVC tape discoloration method should be used cautiously when precise estimates are needed of seasonal changes in the water-table.

  16. A 16-channel cassette tape recorder system for clinical EEGs.

    PubMed

    Barlow, J S

    1975-02-01

    A 16-channel EEG tape recorder system having a frequency response of DC-100 Hz for each channel is described. The system utilized standard commercially available highfidelity audio tape decks in conjunction with specially designed circuits for time-division multiplexing a balanced amplitude modulation

  17. Nurse practitioner preferences for distance education methods related to learning style, course content, and achievement.

    PubMed

    Andrusyszyn, M A; Cragg, C E; Humbert, J

    2001-04-01

    The relationships among multiple distance delivery methods, preferred learning style, content, and achievement was sought for primary care nurse practitioner students. A researcher-designed questionnaire was completed by 86 (71%) participants, while 6 engaged in follow-up interviews. The results of the study included: participants preferred learning by "considering the big picture"; "setting own learning plans"; and "focusing on concrete examples." Several positive associations were found: learning on own with learning by reading, and setting own learning plans; small group with learning through discussion; large group with learning new things through hearing and with having learning plans set by others. The most preferred method was print-based material and the least preferred method was audio tape. The most suited method for content included video teleconferencing for counseling, political action, and transcultural issues; and video tape for physical assessment. Convenience, self-direction, and timing of learning were more important than delivery method or learning style. Preferred order of learning was reading, discussing, observing, doing, and reflecting. Recommended considerations when designing distance courses include a mix of delivery methods, specific content, outcomes, learner characteristics, and state of technology.

  18. In-situ position and vibration measurement of rough surfaces using laser Doppler distance sensors

    NASA Astrophysics Data System (ADS)

    Czarske, J.; Pfister, T.; Günther, P.; Büttner, L.

    2009-06-01

    In-situ measurement of distances and shapes as well as dynamic deformations and vibrations of fast moving and especially rotating objects, such as gear shafts and turbine blades, is an important task at process control. We recently developed a laser Doppler distance frequency sensor, employing two superposed fan-shaped interference fringe systems with contrary fringe spacing gradients. Via two Doppler frequency evaluations the non-incremental position (i.e. distance) and the tangential velocity of rotating bodies are determined simultaneously. The distance uncertainty is in contrast to e.g. triangulation in principle independent of the object velocity. This unique feature allows micrometer resolutions of fast moved rough surfaces. The novel sensor was applied at turbo machines in order to control the tip clearance. The measurements at a transonic centrifugal compressor were performed during operation at up to 50,000 rpm, i.e. 586 m/s velocity of the blade tips. Due to the operational conditions such as temperatures of up to 300 °C, a flexible and robust measurement system with a passive fiber-coupled sensor, using diffractive optics, has been realized. Since the tip clearance of individual blades could be temporally resolved an analysis of blade vibrations was possible. A Fourier transformation of the blade distances results in an average period of 3 revolutions corresponding to a frequency of 1/3 of the rotary frequency. Additionally, a laser Doppler distance sensor using two tilted fringe systems and phase evaluation will be presented. This phase sensor exhibits a minimum position resolution of σz = 140 nm. It allows precise in-situ shape measurements at grinding and turning processes.

  19. Storage, Preservation, and Recovery of Magnetic Recording Tape

    NASA Technical Reports Server (NTRS)

    Cuddihy, Edward F.

    1994-01-01

    During the 1970's, a commercial magnetic recording tape fabricated with magnetic oxide particles, and with oxide and backcoat binders made from polyester urethane was being used for spacecraft tape recorders, and which would periodically manifest operational problems such as layer-to-layer adhesion, stick-slip, and shedding of sticky organic materials. These problems were generally associated with periods of high humidity. An experimental study identified that these problems resulted from hydrolysis of the polyester urethane binders.

  20. Reactivity and oxygen diffusion property of resistive barriers for Bi-2223/Ag tapes

    NASA Astrophysics Data System (ADS)

    Kováč, P.; Hušek, I.

    2002-12-01

    Reactivity of several oxide materials (OM) with BSCCO powder and oxygen diffusion through OM layer has been tested at temperature ≈840 °C in air. The OM (e.g.: BaZrO 3, SrCO 3, MgO and ZrO 2) showing the low or no reactivity with BSCCO have been mixed (10 wt.%) with precursor powder and used for single-core tapes. Bi-2223/Ag/OM/Ag single-core tapes with oxide barriers made of BaZrO 3, SrCO 3, ZrO 2 and Al 2O 3 have been also prepared by a standard powder-in-tube technique. The used OM in the direct contact with BSCCO influences the electrical properties of Bi-2223 phase differently. These is because the oxides react with BSCCO during the heat treatment and simultaneously affect the 2212→2223 phase transformation, the Bi-2223 grain growth and so also grain connectivity. SrCO 3 powder has been evaluated as the best material from the point of no destructive effect on 2223 phase transport current property. The oxide barrier controls the oxygen diffusion during the tape heat treatment and simultaneously the HTS phase formation kinetics, its purity and content within the superconducting core. For single-core Bi-2223/Ag/OM/Ag tapes, the highest current density was measured for Al 2O 3 due to only slightly reduced oxygen diffusion through the barrier.

  1. Burnout Test of First- and Second-Generation HTS Tapes in Liquid-Nitrogen Bath Cooling

    NASA Astrophysics Data System (ADS)

    Young, M. A.; Demko, J. A.; Duckworth, R. C.; Lue, J. W.; Gouge, M. J.; Pace, M. O.

    2004-06-01

    A series of BSCCO-2223 and YBCO tapes were subjected to burnout tests in a liquid-nitrogen bath to observe operational stability limits when different layers of dielectric tape are added to the sample surface. In this study, the BSCCO tapes were composed of a silver/alloy sheath with nickel/copper plating, while the YBCO tapes had a 50-μm layer of copper attached to the silver surface. After attaching the tapes to a thermally insulated G-10 holder, the stability of the tapes was found by applying current greater than the critical current and holding it constant for up to 1 min. If the sample voltage increased rapidly during this period, the tape was considered unstable at this current. This was repeated at different layers of Cryoflex™, and the results were compared to a numerical simulation of the energy balance equation. This simulation was also utilized to investigate the effect of the layers on the stability limit and estimate the thermal conductivity of the Cryoflex™.

  2. Generation and physical characteristics of the Landsat 1 and 2 MSS computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1975-01-01

    The generation and format is discussed of the Landsat 1 and 2 system corrected multispectral scanner computer compatible tapes. Included in the discussion are the spacecraft sensors, scene characteristics, the transmission of data, and the conversion of the data to computer compatible tapes at the NASA Data Processing Facility. Geometric and radiometric corrections, tape formats, and the physical characteristics of the tape are also described.

  3. Kinesio taping compared to physical therapy modalities for the treatment of shoulder impingement syndrome.

    PubMed

    Kaya, Erkan; Zinnuroglu, Murat; Tugcu, Ilknur

    2011-02-01

    The purpose of this study was to determine and compare the efficacy of kinesio tape and physical therapy modalities in patients with shoulder impingement syndrome. Patients (n = 55) were treated with kinesio tape (n = 30) three times by intervals of 3 days or a daily program of local modalities (n = 25) for 2 weeks. Response to treatment was evaluated with the Disability of Arm, Shoulder, and Hand scale. Patients were questioned for the night pain, daily pain, and pain with motion. Outcome measures except for the Disability of Arm, Shoulder, and Hand scale were assessed at baseline, first, and second weeks of the treatment. Disability of Arm, Shoulder, and Hand scale was evaluated only before and after the treatment. Disability of Arm, Shoulder, and Hand scale and visual analog scale scores decreased significantly in both treatment groups as compared with the baseline levels. The rest, night, and movement median pain scores of the kinesio taping (20, 40, and 50, respectively) group were statistically significantly lower (p values were 0.001, 0.01, and 0.001, respectively) at the first week examination as compared with the physical therapy group (50, 70, and 70, respectively). However, there was no significant difference in the same parameters between two groups at the second week (0.109, 0.07, and 0.218 for rest, night, and movement median pain scores, respectively). Disability of Arm, Shoulder, and Hand scale scores of the kinesio taping group were significantly lower at the second week as compared with the physical therapy group. No side effects were observed. Kinesio tape has been found to be more effective than the local modalities at the first week and was similarly effective at the second week of the treatment. Kinesio taping may be an alternative treatment option in the treatment of shoulder impingement syndrome especially when an immediate effect is needed.

  4. Influence of TVT properties on outcomes of midurethral sling procedures: high-stiffness versus low-stiffness tape.

    PubMed

    Prien-Larsen, Jens Christian; Prien-Larsen, Thomas; Cieslak, Lars; Dessau, Ram B

    2016-07-01

    Although there is clear consensus on the use of monofilament polypropylene tapes for treating stress urinary incontinence (SUI), tapes differ in weight, stiffness, and elasticity. In this study, we compared outcomes of two tape types: high-stiffness Intramesh SOFT L.I.F.T versus low-stiffness Intramesh L.I.F.T. tape. Our null hypothesis was that in terms of performance, SOFT tape equaled L.I.F.T. tape. Six hundred and sixty women underwent prospective transvaginal tape (TVT) surgery for SUI: 210 had the SOFT tape placed and 450 the L.I.F.T. tape. Follow-ups were scheduled at 3 and 12 months. Objective cure at 3-months' follow-up was 87 % in the SOFT group vs 94 % in the L.I.F.T. group (p = 0.003) and at 12 months 86 vs 96 % (p = 0.0004), respectively. Subjective outcomes were equal. For SOFT tape, the objective failure rate at 3 months was especially pronounced in women older than 70 years: 31 vs 10 % (p = 0.008), and subjective failure was 24 vs 7 % (p = 0.01). At 12 months, objective failure for the SOFT tape was significantly higher in both age groups compared with L.I.F.T. [odds ratio (OR) 2.17]. Multivariate analysis showed that body mass index (BMI) ≥30 (OR 2.41), mixed incontinence (MUI) (OR 2.24), use of SOFT tape (OR 2.17), and age ≥ 70 years are significant independent risk factors for surgical failure. Outcomes with SOFT tape are significantly inferior than with L.I.F.T. tape, especially among elderly women. Therefore, the two variants of monofilament polypropylene tape are not interchangeable.

  5. JPL Ephemeris Tapes E9510, E9511, and E9512

    NASA Technical Reports Server (NTRS)

    Peabody, P. R.; Scott, J. F.; Orozco, E. G.

    1964-01-01

    The first issue of JPL Ephemeris Tapes is described. These tapes carry the positions and velocities of the planets and of the Moon, plus nutations and nutation rates in longitude and obliquity, together with second and fourth modified differences, for the interval December 30, 1949, to January 5, 2000.

  6. Evaluation of target acquisition difficulty using recognition distance to measure required retinal area

    NASA Astrophysics Data System (ADS)

    Nilsson, Thomy H.

    2001-09-01

    The psychophysical method of limits was used to measure the distance at which observers could distinguish military vehicles photographed in natural landscapes. Obtained from the TNO-TM Search_2 dataset, these pictures either were rear-projected 35-mm slides or were presented on a computer monitor. Based on the rationale that more difficult vehicle targets would require more visual pathways for recognition, difficult of acquisition was defined in terms of the relative retinal area required for recognition. Relative retinal area was derived from the inverse square of the recognition distance of a particular vehicle relative to the distance of the vehicle that could be seen furthest away. Results are compared with data on the time required to find the vehicles in these pictures. These comparison indicate recognition distance thresholds can be a suitable means of defining standards for the effectiveness of vital graphic information; and the two methods are complementary with respect to distinguishing different degrees of acquisition difficulty, and together may provide a means to measure the total information processing required for recognition.

  7. Using DNA origami nanorulers as traceable distance measurement standards and nanoscopic benchmark structures.

    PubMed

    Raab, Mario; Jusuk, Ija; Molle, Julia; Buhr, Egbert; Bodermann, Bernd; Bergmann, Detlef; Bosse, Harald; Tinnefeld, Philip

    2018-01-29

    In recent years, DNA origami nanorulers for superresolution (SR) fluorescence microscopy have been developed from fundamental proof-of-principle experiments to commercially available test structures. The self-assembled nanostructures allow placing a defined number of fluorescent dye molecules in defined geometries in the nanometer range. Besides the unprecedented control over matter on the nanoscale, robust DNA origami nanorulers are reproducibly obtained in high yields. The distances between their fluorescent marks can be easily analysed yielding intermark distance histograms from many identical structures. Thus, DNA origami nanorulers have become excellent reference and training structures for superresolution microscopy. In this work, we go one step further and develop a calibration process for the measured distances between the fluorescent marks on DNA origami nanorulers. The superresolution technique DNA-PAINT is used to achieve nanometrological traceability of nanoruler distances following the guide to the expression of uncertainty in measurement (GUM). We further show two examples how these nanorulers are used to evaluate the performance of TIRF microscopes that are capable of single-molecule localization microscopy (SMLM).

  8. The role of social closeness during tape stripping to facilitate skin barrier recovery: Preliminary findings.

    PubMed

    Robinson, Hayley; Ravikulan, Abhimati; Nater, Urs M; Skoluda, Nadine; Jarrett, Paul; Broadbent, Elizabeth

    2017-07-01

    Social support is known to reduce the negative effects of stress on health, but there is mixed evidence for the effects of social support on wound healing. This study aimed to investigate whether undergoing a task designed to promote social closeness with a fellow participant and being paired with that person during a tape-stripping procedure could reduce stress and improve skin barrier recovery compared to going through tape stripping alone. Seventy-two healthy adults were randomized to either a social closeness condition where participants completed a relationship-building task and tape stripping in pairs or a control condition where they completed tape stripping alone. Skin barrier recovery was measured using transepidermal water loss. Salivary cortisol and alpha-amylase were collected at four time points as markers of the endocrine and autonomic stress response. Social closeness had a beneficial effect on skin barrier recovery compared to the control condition, t(54) = 2.86, p = .006, r = .36. Social closeness significantly reduced self-reported stress. The effects of the intervention on skin barrier recovery were moderated by self-reported stress reduction (p = .035). There were no significant differences in cortisol between groups, but alpha-amylase increased significantly more from baseline to after tape stripping in the control group compared to the intervention group. This is the first study to show that social closeness with a person going through a similar unfamiliar procedure can positively influence wound healing. Future research needs to replicate these findings in other wound types and in clinical settings. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  9. Simultaneous distance measurement at multiple wavelengths using the intermode beats from a femtosecond laser coherent supercontinuum

    NASA Astrophysics Data System (ADS)

    Salido-Monzú, David; Wieser, Andreas

    2018-04-01

    The intermode beats generated by direct detection of a mode-locked femtosecond laser represent inherent high-quality and high-frequency modulations suitable for electro-optical distance measurement (EDM). This approach has already been demonstrated as a robust alternative to standard long-distance EDM techniques. However, we extend this idea to intermode beating of a wideband source obtained by spectral broadening of a femtosecond laser. We aim at establishing a technological basis for accurate and flexible multiwavelength distance measurement. Results are presented from experiments using beat notes at 1 GHz generated by two bandpass-filtered regions from both extremes of a coherent supercontinuum ranging from 550 to 1050 nm. The displacement measurements performed simultaneously on both colors on a short-distance setup show that noise and coherence of the wideband laser are adequate for achieving accuracies of about 0.01 mm on each channel with a potential improvement by accessing higher beat notes. Pointing and power instabilities have been identified as dominant sources of systematic deviations. Nevertheless, the results demonstrate the basic feasibility of the proposed technique. We consider this a promising starting point for the further development of multiwavelength EDM enabling increased accuracy over long distances through dispersion-based integral refractivity compensation and for remote surface material probing along with distance measurement in laser scanning.

  10. High current density electropolishing in the preparation of highly smooth substrate tapes for coated conductors

    DOEpatents

    Kreiskott, Sascha [Los Alamos, NM; Matias, Vladimir [Santa Fe, NM; Arendt, Paul N [Los Alamos, NM; Foltyn, Stephen R [Los Alamos, NM; Bronisz, Lawrence E [Los Alamos, NM

    2009-03-31

    A continuous process of forming a highly smooth surface on a metallic tape by passing a metallic tape having an initial roughness through an acid bath contained within a polishing section of an electropolishing unit over a pre-selected period of time, and, passing a mean surface current density of at least 0.18 amperes per square centimeter through the metallic tape during the period of time the metallic tape is in the acid bath whereby the roughness of the metallic tape is reduced. Such a highly smooth metallic tape can serve as a base substrate in subsequent formation of a superconductive coated conductor.

  11. Detection of latent fingerprint hidden beneath adhesive tape by optical coherence tomography.

    PubMed

    Zhang, Ning; Wang, Chengming; Sun, Zhenwen; Li, Zhigang; Xie, Lanchi; Yan, Yuwen; Xu, Lei; Guo, Jingjing; Huang, Wei; Li, Zhihui; Xue, Jing; Liu, Huan; Xu, Xiaojing

    2018-06-01

    Adhesive tape is one type of common item which can be encountered in criminal cases involving rape, murder, kidnapping and explosives. It is often the case that a suspect deposits latent fingerprints on the sticky side of adhesive tape material when tying up victims, manufacturing improvised explosive devices or packaging illegal goods. However, the adhesive tapes found at crime scenes are usually stuck together or attached to a certain substrate, and thus the latent fingerprints may be hidden beneath the tapes. Current methods to detect latent fingerprint hidden beneath adhesive tape need to peel it off first and then apply physical or chemical methods to develop the fingerprint, which undergo complicated procedures and would affect the original condition of latent print. Optical coherence tomography (OCT) is a novel applied techniques in forensics which enables obtaining cross-sectional structure with the advantages of non-invasive, in-situ, high resolution and high speed. In this paper, a custom-built spectral-domain OCT (SD-OCT) system with a hand-held probe was employed to detect fingerprints hidden beneath different types of adhesive tapes. Three-dimensional (3D) OCT reconstructions were performed and the en face images were presented to reveal the hidden fingerprints. The results demonstrate that OCT is a promising tool for rapidly detecting and recovering high quality image of latent fingerprint hidden beneath adhesive tape without any changes to the original state and preserve the integrity of the evidence. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. The Influence of the Tape-Recorder on Attainment in EFL.

    ERIC Educational Resources Information Center

    Al-Ansari, Saif; Wigzell, Roy

    1996-01-01

    Reports a study undertaken in Bahrain secondary schools to assess the contribution of tape recorders to learning outcomes in English as a Second Language (ESL). Findings revealed that students' proficiency correlated significantly with their perception of the frequency and skill with which their teacher use a tape recorder. (20 references)…

  13. 41 CFR 101-26.508-2 - Requisitioning data processing tape not available from Federal Supply Schedule contracts.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... contracts. (a) Requisitions for types of EDP tape and instrumentation tape (wide and intermediate band... is located. (b) Requisitions for all types of EDP tape and instrumentation tape (wide and... and $5,000 for instrumentation tape. However, regardless of the amount involved (including...

  14. Age-of-Air, Tape Recorder, and Vertical Transport Schemes

    NASA Technical Reports Server (NTRS)

    Lin, S.-J.; Einaudi, Franco (Technical Monitor)

    2000-01-01

    A numerical-analytic investigation of the impacts of vertical transport schemes on the model simulated age-of-air and the so-called 'tape recorder' will be presented using an idealized 1-D column transport model as well as a more realistic 3-D dynamical model. By comparing to the 'exact' solutions of 'age-of-air' and the 'tape recorder' obtainable in the 1-D setting, useful insight is gained on the impacts of numerical diffusion and dispersion of numerical schemes used in global models. Advantages and disadvantages of Eulerian, semi-Lagrangian, and Lagrangian transport schemes will be discussed. Vertical resolution requirement for numerical schemes as well as observing systems for capturing the fine details of the 'tape recorder' or any upward propagating wave-like structures can potentially be derived from the 1-D analytic model.

  15. An acoustic thermometer for air refractive index estimation in long distance interferometric measurements

    NASA Astrophysics Data System (ADS)

    Pisani, Marco; Astrua, Milena; Zucco, Massimo

    2018-02-01

    We present a method to measure the temperature along the path of an optical interferometer based on the propagation of acoustic waves. It exploits the high sensitivity of the speed of sound to air temperature. In particular, it takes advantage of a technique where the generation of acoustic waves is synchronous with the amplitude modulation of a laser source. A photodetector converts the laser light into an electronic signal used as a reference, while the incoming acoustic waves are focused on a microphone and generate the measuring signal. Under this condition, the phase difference between the two signals substantially depends on the temperature of the air volume interposed between the sources and the receivers. A comparison with traditional temperature sensors highlighted the limit of the latter in the case of fast temperature variations and the advantage of a measurement integrated along the optical path instead of a sampling measurement. The capability of the acoustic method to compensate for the interferometric distance measurements due to air temperature variations has been demonstrated to the level of 0.1 °C corresponding to 10-7 on the refractive index of air. We applied the method indoor for distances up to 27 m, outdoor at 78 m and finally tested the acoustic thermometer over a distance of 182 m.

  16. Kinesiology Taping reduces lymphedema of the upper extremity in women after breast cancer treatment: a pilot study

    PubMed Central

    Rosseger, Agnieszka; Hanuszkiewicz, Justyna; Woźniewski, Marek

    2014-01-01

    Introduction Secondary lymphedema affects approximately 40% of women treated for breast cancer and is recognized as a major problem associated with the therapy of malignant tumors. Consequently, new therapeutic methods are constantly being sought to effectively eliminate the condition. One of the new forms of edema management, especially in the initial stages of edematous development, is Kinesiology Taping (KT). Aim of the study The aim of the study was to assess the effects of KT applications on the extent of lymphedema of the upper extremity in women post cancer treatment. Material and methods The study group consisted of 28 women after axillary lymphadenectomy due to breast cancer. All the patients were diagnosed with grade I secondary lymphedema. Kinesiology Taping was applied to a total of 14 randomly selected women. The remaining 14 patients constituted a control group. The extent of lymphedema was measured using a centimeter tape and Limb Volumes Professional 5.0 software. Results A significant reduction in the extent of lymphedema (p = 0.0009) was achieved in the KT group between baseline and post-treatment assessments. No such reduction, however, was found in the control group (p = 0.36). Conclusions Kinesiology Taping applications are an effective method of early-stage edema management. Kinesiology Taping may be a safe new therapeutic option in patients who are contraindicated for the use of other methods. PMID:26327858

  17. The morphologic changes in lamellar bodies and intercorneocyte lipids after tape stripping and occlusion with a water vapor-impermeable membrane.

    PubMed

    Jiang, S; Koo, S W; Lee, S H

    1998-03-01

    It has been reported that artificial restoration of barrier function by a water vapor-impermeable membrane after tape stripping induces barrier abrogation in hairless mice, impeding rather than enhancing barrier recovery. To address this issue, we examined the morphologic changes in the epidermis after tape stripping and occlusion with a water vapor-impermeable membrane in murine skin. Male hairless mice were used for all studies of barrier perturbation and occlusion. Barrier disruption was achieved by repeated application of cellophane tape. Immediately after tape stripping the animals were wrapped in a tightly fitting water vapor-impermeable membrane. Transepidermal water loss (TEWL) was measured 20 min after tape stripping and 14, 24, 36, 48 and 60 h after occlusion. For electron microscopy the samples were treated with osmium tetroxide (OsO4) or ruthenium tetroxide (RuO4). When tape-stripped animals were wrapped in a water vapor-impermeable membrane, thereby preventing water flux, barrier function did not recover normally. These results demonstrate that an artificial block to TEWL with an impermeable membrane did not enhance barrier recovery. By electron microscopy many transitional cells and lacunae of various sizes were seen within the intercellular spaces of the stratum corneum after occlusion following tape stripping. Occlusion also caused alterations in both lipid lamellar membrane structures in the stratum corneum interstices and the lamellar bodies in the cytosol of granulocytes and transitional cells. Secreted lamellar body contents also appeared to be abnormal in the stratum corneum-stratum granulosum junction.

  18. Use of adhesive surgical tape with the absorbable continuous subcuticular suture.

    PubMed

    Kolt, Jeremy D

    2003-08-01

    The absorbable continuous subcuticular suture is frequently used to close surgical incisions where the aim is healing by primary intention. A form of adhesive surgical tape is commonly also placed over the wound but this combination closure seems to have its development based on anecdotal, rather than experimental evidence. The present study reviews the scientific literature on the development of sutureless wound closure and presents the current evidence for the use of combination wound closure. Review was undertaken of the medical literature using the PubMed Internet database and cross-referencing major -articles on the subject. The following combinations of key words were searched: skin closure, wound closure, suture technique, sutureless, adhesive tape, op-site, staples, subcuticular suture, complication, infection and scars. Taped closure alone has advantages of lower wound infection rates and greater wound tensile strength, but disadvantages of epidermal reaction, skin edge inversion, doubtful safety and time required for meticulous surgical technique. The use of the continuous absorbable subcuticular suture allows accurate skin edge approximation, which increases the safety margin. The combination closure has a slightly superior cosmetic result to sutureless techniques but no study has been performed to compare the results of combination subcuticular suture and tape, with tape or subcuticular suture alone. There is no evidence in the scientific literature to justify or support the practice of closing a surgical wound with both subcuticular suture and adhesive surgical tape.

  19. AC losses in horizontally parallel HTS tapes for possible wireless power transfer applications

    NASA Astrophysics Data System (ADS)

    Shen, Boyang; Geng, Jianzhao; Zhang, Xiuchang; Fu, Lin; Li, Chao; Zhang, Heng; Dong, Qihuan; Ma, Jun; Gawith, James; Coombs, T. A.

    2017-12-01

    This paper presents the concept of using horizontally parallel HTS tapes with AC loss study, and the investigation on possible wireless power transfer (WPT) applications. An example of three parallel HTS tapes was proposed, whose AC loss study was carried out both from experiment using electrical method; and simulation using 2D H-formulation on the FEM platform of COMSOL Multiphysics. The electromagnetic induction around the three parallel tapes was monitored using COMSOL simulation. The electromagnetic induction and AC losses generated by a conventional three turn coil was simulated as well, and then compared to the case of three parallel tapes with the same AC transport current. The analysis demonstrates that HTS parallel tapes could be potentially used into wireless power transfer systems, which could have lower total AC losses than conventional HTS coils.

  20. Towards a 1000 tracks digital tape recorder

    NASA Technical Reports Server (NTRS)

    Coutellier, J. M.; Castera, J. P.; Colineau, J.; Lehureau, J. C.; Maurice, F.; Hanna, C.

    1993-01-01

    As the demand for high data rate (up to 1 Gb/s), high density (down to 1 sq micron/bit) tape recorder increases, the main investigation trend is an improvement of the well known helical scan concept. The drawbacks of this technology are also well known; sophisticated mechanics, head to tape contact, and wear problems. In our fixed head approach, the recorder mechanics is made much more simple, but the complexity is turned towards the integrated magnetic components, which have to record and reproduce hundreds of tracks in parallel. Our multiplexed write inductive head and magneto-optical readout head will be described, and the global system performances evaluated.

  1. STScI-PRC96-21b DISTANCE MEASUREMENTS TO A TYPE-IA SUPERNOVA BEARING GALAXY

    NASA Technical Reports Server (NTRS)

    2002-01-01

    This Hubble Space Telescope image shows NGC 4639, a spiral galaxy located 78 million light-years away in the Virgo cluster of galaxies. The blue dots in the galaxy's outlying regions indicate the presence of young stars. Among them are young, bright stars called Cepheids, which are used as reliable milepost markers to obtain accurate distances to nearby galaxies. Astronomers measure the brightness of Cepheids to calculate the distance to a galaxy. Allan Sandage's team used Cepheids to measure the distance to NGC 4639, the farthest galaxy to which Cepheid distance has been calculated. After using Cepheids to calculate the distance to NGC 4639, the team compared the results to the peak brightness measurements of SN 1990N, a type Ia supernova located in the galaxy. Then they compared those numbers with the peak brightness of supernovae similarly calibrated in nearby galaxies. The team then determined that type Ia supernovae are reliable secondary distance markers, and can be used to determine distances to galaxies several hundred times farther away than Cepheids. An accurate value for the Hubble Constant depends on Cepheids and secondary distance methods. The color image was made from separate exposures taken in the visible and near-infrared regions of the spectrum with the Wide Field Planetary Camera 2. Credit: A. Sandage (Carnegie Observatories), A. Saha (Space Telescope Science Institute), G.A. Tammann, and L. Labhardt (Astronomical Institute, University Basel), F.D. Macchetto and N. Panagia (Space Telescope Science Institute/ European Space Agency), and NASA Image files in GIF and JPEG format and captions may be accessed on Internet via anonymous ftp from oposite.stsci.edu in /pubinfo.

  2. Integration of altitude and airspeed information into a primary flight display via moving-tape formats

    NASA Technical Reports Server (NTRS)

    Abbott, Terence S.; Steinmetz, George G.

    1987-01-01

    A ground-based aircraft simulation study was conducted to determine the effect on pilot performance of replacing the electromechanical altimeter and airspeed indicators with electronically generated representations integrated into the primary flight display via moving-tape (linear moving scale) formats. Several key factors relating to moving-tape formats were examined during the study: tape centering, secondary (trend) information, and tape orientation. The factor of centering refers to whether the tape was centered about the actual airspeed or altitude or about some defined reference value. Tape orientation refers to whether the values represented are arranged in either descending or ascending order. Six pilots participated in this study, with each subject performing 18 runs along a single, known flight profile. Subjective results indicated that the moving-tape formats were generally better than that of the conventional instruments. They also indicated that an actual-centered fixed pointer was preferred to a reference-centered pointer. Performance data for a visual secondary task showed that formats not containing trend information produced better performance; however, no difference was noted in airspeed tracking or altitude tracking performance. Regarding tape orientation, subjective comments indicated that there was lower work load and better performance when the airspeed tape had the high numbers at the top.

  3. Pupil diameter, working distance and illumination during habitual tasks. Implications for simultaneous vision contact lenses for presbyopia.

    PubMed

    Cardona, Genís; López, Sílvia

    2016-01-01

    To determine working distance, pupil diameter and illumination in real life conditions in a sample of presbyopic participants performing habitual tasks. A total of 59 presbyopic subjects (aged between 45 and 63 years) with different occupational backgrounds participated in the study. Participants were first interviewed regarding their habitual tasks with the aid of an ad hoc questionnaire, following which in-office photopic and mesopic pupil diameter was determined. Pupil diameter was also evaluated while participants conducted each of the self-reported habitual tasks by taking a photograph, which was later submitted to image analysis. In addition, working distance was determined with a measuring tape and the illumination that reached the pupil during each of the different tasks was measured, in lux, with a light meter. The four most common habitual tasks were computer use, reading, sewing and sports. A high intersubject variability was found in pupil diameter, working distance and illumination conditions while conducting the same task. Statistically significant differences were found between the in-office measured photopic and mesopic pupil diameters and those obtained while participants were conducting their habitual tasks in real life conditions (all p<0.001). Potential multifocal contact lens users may present with different ages, different jobs or hobbies and different preferences regarding lighting conditions and working distances. This results in different pupil size, even within the same task. This information may be critical when selecting a particular lens design and add power. Eye care practitioners are therefore advised to assess pupil diameter in real life conditions. Copyright © 2015 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  4. Scan converting video tape recorder

    NASA Technical Reports Server (NTRS)

    Holt, N. I. (Inventor)

    1971-01-01

    A video tape recorder is disclosed of sufficient bandwidth to record monochrome television signals or standard NTSC field sequential color at current European and American standards. The system includes scan conversion means for instantaneous playback at scanning standards different from those at which the recording is being made.

  5. Influence of gamma ray irradiation on thermal conductivity of bismaleimide-triazine-based insulation tape at cryogenic temperature

    NASA Astrophysics Data System (ADS)

    Yang, Y.; Yoshida, M.; Idesaki, A.; Ogitsu, T.

    2018-01-01

    Recent accelerator-based experiments for particle physics require the superconducting magnets that can be operated under high radiation environment. An electrical insulation tape, which is composed of polyimide film and a boron free glass fabric pre-impregnated with epoxy resin blended with bismaleimide-triazine resin, is developed to enhance the radiation tolerance for superconducting magnets. Since the thermal conductivity of insulation tape is one of key parameters that affects the coil temperature during the operation, the influence of gamma-ray irradiation on the thermal conductivity of the insulation tape is investigated with a maximum dose of 5 MGy. The thermal conductivity is measured at cryogenic temperature from 5 K to 20 K cooled by a Gifford-McMahon cryocooler. By comparing the thermal conductivity before and after the gamma ray irradiation, no significant degradation on the thermal conductivity has been observed.

  6. Effect of kinesiotaping, non-elastic taping and bracing on segmental foot kinematics during drop landing in healthy subjects and subjects with chronic ankle instability.

    PubMed

    Kuni, B; Mussler, J; Kalkum, E; Schmitt, H; Wolf, S I

    2016-09-01

    To evaluate the effects of kinesiotape, non-elastic tape, and soft brace on segmental foot kinematics during drop landing in subjects with chronic ankle instability and healthy subjects. Controlled study with repeated measurements. Three-dimensional motion analysis laboratory. Twenty participants with chronic ankle instability and 20 healthy subjects. The subjects performed drop landings with 17 retroreflective markers on the foot and lower leg in four conditions: barefoot, with kinesiotape, with non-elastic tape and with a soft brace. Ranges of motion of foot segments using a foot measurement method. In participants with chronic ankle instability, midfoot movement in the frontal plane (inclination of the medial arch) was reduced significantly by non-elastic taping, but kinesiotaping and bracing had no effect. In healthy subjects, both non-elastic taping and bracing reduced that movement. In both groups, non-elastic taping and bracing reduced rearfoot excursion in inversion/eversion significantly, which indicates a stabilisation effect. No such effect was found with kinesiotaping. All three methods reduced maximum plantar flexion significantly. Non-elastic taping stabilised the midfoot best in patients with chronic ankle instability, while kinesiotaping did not influence foot kinematics other than to stabilise the rearfoot in the sagittal plane. ClinicalTrials.gov NCT01810471. Copyright © 2015 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  7. 41 CFR 301-10.302 - How do I determine distance measurements for my travel?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... distance measurements for my travel? 301-10.302 Section 301-10.302 Public Contracts and Property Management Federal Travel Regulation System TEMPORARY DUTY (TDY) TRAVEL ALLOWANCES ALLOWABLE TRAVEL EXPENSES 10... my travel? If you travel by The distance between your origin and destination is Privately owned...

  8. 41 CFR 301-10.302 - How do I determine distance measurements for my travel?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... distance measurements for my travel? 301-10.302 Section 301-10.302 Public Contracts and Property Management Federal Travel Regulation System TEMPORARY DUTY (TDY) TRAVEL ALLOWANCES ALLOWABLE TRAVEL EXPENSES 10... my travel? If you travel by The distance between your origin and destination is Privately owned...

  9. 41 CFR 301-10.302 - How do I determine distance measurements for my travel?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... distance measurements for my travel? 301-10.302 Section 301-10.302 Public Contracts and Property Management Federal Travel Regulation System TEMPORARY DUTY (TDY) TRAVEL ALLOWANCES ALLOWABLE TRAVEL EXPENSES 10... my travel? If you travel by The distance between your origin and destination is Privately owned...

  10. 41 CFR 301-10.302 - How do I determine distance measurements for my travel?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... distance measurements for my travel? 301-10.302 Section 301-10.302 Public Contracts and Property Management Federal Travel Regulation System TEMPORARY DUTY (TDY) TRAVEL ALLOWANCES ALLOWABLE TRAVEL EXPENSES 10... my travel? If you travel by The distance between your origin and destination is Privately owned...

  11. 41 CFR 301-10.302 - How do I determine distance measurements for my travel?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... distance measurements for my travel? 301-10.302 Section 301-10.302 Public Contracts and Property Management Federal Travel Regulation System TEMPORARY DUTY (TDY) TRAVEL ALLOWANCES ALLOWABLE TRAVEL EXPENSES 10... my travel? If you travel by The distance between your origin and destination is Privately owned...

  12. Influence of viscoelastic nature on the intermittent peel-front dynamics of adhesive tape

    NASA Astrophysics Data System (ADS)

    Kumar, Jagadish; Ananthakrishna, G.

    2010-07-01

    We investigate the influence of viscoelastic nature of the adhesive on the intermittent peel front dynamics by extending a recently introduced model for peeling of an adhesive tape. As time and rate-dependent deformation of the adhesives are measured in stationary conditions, a crucial step in incorporating the viscoelastic effects applicable to unstable intermittent peel dynamics is the introduction of a dynamization scheme that eliminates the explicit time dependence in terms of dynamical variables. We find contrasting influences of viscoelastic contribution in different regions of tape mass, roller inertia, and pull velocity. As the model acoustic energy dissipated depends on the nature of the peel front and its dynamical evolution, the combined effect of the roller inertia and pull velocity makes the acoustic energy noisier for small tape mass and low-pull velocity while it is burstlike for low-tape mass, intermediate values of the roller inertia and high-pull velocity. The changes are quantified by calculating the largest Lyapunov exponent and analyzing the statistical distributions of the amplitudes and durations of the model acoustic energy signals. Both single and two stage power-law distributions are observed. Scaling relations between the exponents are derived which show that the exponents corresponding to large values of event sizes and durations are completely determined by those for small values. The scaling relations are found to be satisfied in all cases studied. Interestingly, we find only five types of model acoustic emission signals among multitude of possibilities of the peel front configurations.

  13. Blood loss in the space of Retzius and pelvis with tension-free vaginal tape and trans-obturator tape procedures.

    PubMed

    Huffaker, R Keith; Copas, Pleas

    2006-11-01

    The purpose of this study was to evaluate the space of Retzius and pelvis for hematoma formation and blood loss following placement of tension-free vaginal tapes (TVT) and transobturator tapes (TOT). 25 women were examined with ultrasonography on post-operative days one, two, three, four or five. One patient underwent TVT while the other 24 underwent TOT. Additional procedures were performed on most patients. No hematomas or collections of free fluid were identified post-operatively. TVT and TOT procedures are relatively safe procedures. We encountered no vascular complications in this small series of patients. Review of literature has yielded reports of infrequent complications.

  14. Water-vapor effects on friction of magnetic tape in contact with nickel-zinc ferrite

    NASA Technical Reports Server (NTRS)

    Miyoshi, K.; Buckley, D. H.

    1984-01-01

    The effects of humidity of moist nitrogen on the friction and deformation behavior of magnetic tape in contact with a nickel-zinc ferrite spherical pin were studied. The results indicate that the coefficient of friction is markedly dependent on the ambient relative humidity. Although the coefficient of friction remains low below 40-percent relative humidity, it increases rapidly with increasing relative humidity above 40 percent. The general ambient environment of the tape does not have any effect on the friction behavior if the area where the tape is in sliding contact with the ferrite pin is flooded with controlled nitrogen. The response time for the friction of the tape to humidity changes is about 10 sec. The effect of friction as a function of relative humidity on dehumidifying is very similar to that on humidifying. A surface softening of the tape due to water vapor increases the friction of the tape.

  15. EPR-based distance measurements at ambient temperature.

    PubMed

    Krumkacheva, Olesya; Bagryanskaya, Elena

    2017-07-01

    Pulsed dipolar (PD) EPR spectroscopy is a powerful technique allowing for distance measurements between spin labels in the range of 2.5-10.0nm. It was proposed more than 30years ago, and nowadays is widely used in biophysics and materials science. Until recently, PD EPR experiments were limited to cryogenic temperatures (T<80K). Recently, application of spin labels with long electron spin dephasing time at room temperature such as triarylmethyl radicals and nitroxides with bulky substituents at a position close to radical centers enabled measurements at room temperature and even at physiologically relevant temperatures by PD EPR as well as other approaches based on EPR (e.g., relaxation enhancement; RE). In this paper, we review the features of PD EPR and RE at ambient temperatures, in particular, requirements on electron spin phase memory time, ways of immobilization of biomolecules, the influence of a linker between the spin probe and biomolecule, and future opportunities. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Distance-Based Functional Diversity Measures and Their Decomposition: A Framework Based on Hill Numbers

    PubMed Central

    Chiu, Chun-Huo; Chao, Anne

    2014-01-01

    Hill numbers (or the “effective number of species”) are increasingly used to characterize species diversity of an assemblage. This work extends Hill numbers to incorporate species pairwise functional distances calculated from species traits. We derive a parametric class of functional Hill numbers, which quantify “the effective number of equally abundant and (functionally) equally distinct species” in an assemblage. We also propose a class of mean functional diversity (per species), which quantifies the effective sum of functional distances between a fixed species to all other species. The product of the functional Hill number and the mean functional diversity thus quantifies the (total) functional diversity, i.e., the effective total distance between species of the assemblage. The three measures (functional Hill numbers, mean functional diversity and total functional diversity) quantify different aspects of species trait space, and all are based on species abundance and species pairwise functional distances. When all species are equally distinct, our functional Hill numbers reduce to ordinary Hill numbers. When species abundances are not considered or species are equally abundant, our total functional diversity reduces to the sum of all pairwise distances between species of an assemblage. The functional Hill numbers and the mean functional diversity both satisfy a replication principle, implying the total functional diversity satisfies a quadratic replication principle. When there are multiple assemblages defined by the investigator, each of the three measures of the pooled assemblage (gamma) can be multiplicatively decomposed into alpha and beta components, and the two components are independent. The resulting beta component measures pure functional differentiation among assemblages and can be further transformed to obtain several classes of normalized functional similarity (or differentiation) measures, including N-assemblage functional generalizations of

  17. Distance-based functional diversity measures and their decomposition: a framework based on Hill numbers.

    PubMed

    Chiu, Chun-Huo; Chao, Anne

    2014-01-01

    Hill numbers (or the "effective number of species") are increasingly used to characterize species diversity of an assemblage. This work extends Hill numbers to incorporate species pairwise functional distances calculated from species traits. We derive a parametric class of functional Hill numbers, which quantify "the effective number of equally abundant and (functionally) equally distinct species" in an assemblage. We also propose a class of mean functional diversity (per species), which quantifies the effective sum of functional distances between a fixed species to all other species. The product of the functional Hill number and the mean functional diversity thus quantifies the (total) functional diversity, i.e., the effective total distance between species of the assemblage. The three measures (functional Hill numbers, mean functional diversity and total functional diversity) quantify different aspects of species trait space, and all are based on species abundance and species pairwise functional distances. When all species are equally distinct, our functional Hill numbers reduce to ordinary Hill numbers. When species abundances are not considered or species are equally abundant, our total functional diversity reduces to the sum of all pairwise distances between species of an assemblage. The functional Hill numbers and the mean functional diversity both satisfy a replication principle, implying the total functional diversity satisfies a quadratic replication principle. When there are multiple assemblages defined by the investigator, each of the three measures of the pooled assemblage (gamma) can be multiplicatively decomposed into alpha and beta components, and the two components are independent. The resulting beta component measures pure functional differentiation among assemblages and can be further transformed to obtain several classes of normalized functional similarity (or differentiation) measures, including N-assemblage functional generalizations of the

  18. Ceramic-metal composites prepared via tape casting and melt infiltration methods

    NASA Astrophysics Data System (ADS)

    Kim, Hyun Jun

    Melt infiltration of preforms prepared by tape casting and lamination has been accomplished using a short-time infiltration process that significantly suppresses reaction product formation. For layered materials produced via infiltration of laminated ceramic tapes, of particular interest is the effect that a large change in microstructure has on infiltration, phase formation, and mechanical properties. Hardness of the fine scale composite layers is approximately three times higher than coarse scale layers, due to greater strength of the fine B4C network. Fractography showed that crack propagation occurred by brittle fracture of the carbide and ductile extension of the metal. Despite large differences in hardness, the fracture mode of the fine and coarse scale microstructures appears identical. Fluid flow modeling for tape casting was conducted with a Newtonian slurry under a parallel blade, and the effect of beveling the blade based on a one dimensional flow model is shown. The discussion on slurry deformation after the blade exit suggests that the mode of slurry deformation depends on the relative importance of the pressure gradient and wall shear and that the existence of zero shear plane might have a negative effect on particle alignment in the tape. The analysis of the flow under a beveled blade predicts that this configuration is more advantageous than the parallel blade for productivity and parallel blade is better for producing uniform particle alignment and thinner tape. Also, the one dimensional flow model for the beveled blade is shown to be a valid approximation of the fluid behavior below a blade angle of 45 degrees. The flow visualization study on tape casting was conducted with a transparent apparatus and model slurry. Most investigators have concluded that the shear stress between the doctor blade and moving carrier causes the particle alignment, but, according to the result of visualization experiment, some degree of particle alignment is already

  19. Application of digital image correlation for long-distance bridge deflection measurement

    NASA Astrophysics Data System (ADS)

    Tian, Long; Pan, Bing; Cai, Youfa; Liang, Hui; Zhao, Yan

    2013-06-01

    Due to its advantages of non-contact, full-field and high-resolution measurement, digital image correlation (DIC) method has gained wide acceptance and found numerous applications in the field of experimental mechanics. In this paper, the application of DIC for real-time long-distance bridge deflection detection in outdoor environments is studied. Bridge deflection measurement using DIC in outdoor environments is more challenging than regular DIC measurements performed under laboratory conditions. First, much more image noise due to variations in ambient light will be presented in the images recorded in outdoor environments. Second, how to select the target area becomes a key factor because long-distance imaging results in a large field of view of the test object. Finally, the image acquisition speed of the camera must be high enough (larger than 100 fps) to capture the real-time dynamic motion of a bridge. In this work, the above challenging issues are addressed and several improvements were made to DIC method. The applicability was demonstrated by real experiments. Experimental results indicate that the DIC method has great potentials in motion measurement in various large building structures.

  20. Generation and physical characteristics of the LANDSAT-1, -2 and -3 MSS computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1977-01-01

    The generation and format of the LANDSAT 1, 2, and 3 system corrected multispectral scanner computer compatible tapes are discussed. Included in the discussion are the spacecraft sensors, scene characteristics, the transmission of data, and the conversion of the data to computer compatible tapes. Also included in the discussion are geometric and radiometric corrections, tape formats, and the physical characteristics of the tape.

  1. The Goddard helical tape recorder

    NASA Technical Reports Server (NTRS)

    Martin, F. T.; Mccarthy, D. K.

    1972-01-01

    A spacecraft recorder was developed with the objective of functioning continuously for 5 years. The resulting design employed a metallic tape wound in a 200-turn helix. A direct drive, brushless dc torquer and servo speed control drove the recorder at 3 rpm for recording and 54 rpm for playback.

  2. Distribution of two western clapper rail races as determined by responses to taped calls

    USGS Publications Warehouse

    Tomlinson, R.E.; Todd, R.L.

    1973-01-01

    During 1969 and 1970, surveys of the endangered Yuma Clapper Rail were conducted using taped calls to elicit responses from the birds. During the two summers, more than 158 Yuma clappers were located in cattailtule marshes along the Colorado River south of Needles, California, to the International Boundary, a distance of about 240 miles. Clappers (probably of the same race) were also found in estuarian marshes of the Colorado River Delta of Mexico; in the Salton Sea; in two freshwater marsh areas near Phoenix, Arizona; and in two freshwater marshes adjacent to the lower Gila River near Tacna, Arizona.....Populations of Sonora Clapper Rails were discovered as permanent residents in five separate mangrove swamps along the west coast of Mexico in the vicinity of Kino Bay, Sonora. These observations were farther north than any heretofore reported for the race R. l. rhizophorae, and the swamps also represent the extreme northward limit of mangroves in Sonora.....During the winter, Yuma clappers did not respond to taped calls north of the International Boundary, whereas clappers along the coast of Sonora readily answered the calls during the same period of time. We conclude that most Yuma Clapper Rails migrate from their summer habitat along the Colorado River in September and do not return to the breeding areas until late April.

  3. Determination of Extrapolation Distance with Measured Pressure Signatures from Two Low-Boom Models

    NASA Technical Reports Server (NTRS)

    Mack, Robert J.; Kuhn, Neil

    2004-01-01

    A study to determine a limiting distance to span ratio for the extrapolation of near-field pressure signatures is described and discussed. This study was to be done in two wind-tunnel facilities with two wind-tunnel models. At this time, only the first half had been completed, so the scope of this report is limited to the design of the models, and to an analysis of the first set of measured pressure signatures. The results from this analysis showed that the pressure signatures measured at separation distances of 2 to 5 span lengths did not show the desired low-boom shapes. However, there were indications that the pressure signature shapes were becoming 'flat-topped'. This trend toward a 'flat-top' pressure signatures shape was seen to be a gradual one at the distance ratios employed in this first series of wind-tunnel tests.

  4. Goddard Space Flight Center specification for Helical-Scan 8-millimeter (mm) magnetic digital data tape cartridge

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1992-01-01

    The same kind of standard and controls are established that are currently in use for the procurement of new analog, digital, and IBM/IBM compatible 3480 tape cartridges, and 1 in wide channel video magnetic tapes. The Magnetic Tape Certification Facility (MTCF) maintains a Qualified Products List (QPL) for the procurement of new magnetic media and uses the following specifications for the QPL and Acceptance Tests: (1) NASA TM-79724 is used for the QPL and Acceptance Testing of new analog magnetic tapes; (2) NASA TM-80599 is used for the QPL and Acceptance Testing of new digital magnetic tapes; (3) NASA TM-100702 is used for the QPL and Acceptance Testing of new IBM/IBM compatible 3840 magnetic tape cartridges; and (4) NASA TM-100712 is used for the QPL and Acceptance Testing of new 1 in wide channel video magnetic tapes. This document will be used for the QPL and Acceptance Testing of new Helical Scan 8 mm digital data tape cartridges.

  5. Hygrothermomechanical evaluation of transverse filament tape epoxy/polyester fiberglass composites

    NASA Technical Reports Server (NTRS)

    Lark, R. F.; Chamis, C. C.

    1984-01-01

    Transverse filament tape (TFT) fiberglass/epoxy and TFT polyester composites intended for low cost wind turbine blade fabrication have been subjected to static and cyclic load behavior tests whose results are presently evaluated on the basis of an integrated hygrothermomechanical response theory. Laminate testing employed simulated filament winding procedures. The results obtained show that the predicted hygrothermomechanical environmental effects on TFT composites are in good agreement with measured data for various properties, including fatigue at different R-ratio values.

  6. Visualization of latent fingerprints beneath opaque electrical tapes by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Liu, Kangkang; Zhang, Ning; Meng, Li; Li, Zhigang; Xu, Xiaojing

    2018-03-01

    Electrical tape is found as one type of important trace evidence in crime scene. For example, it is very frequently used to insulate wires in explosive devices in many criminal cases. The fingerprints of the suspects were often left on the adhesive side of the tapes, which can provide very useful clues for the investigation and make it possible for individual identification. The most commonly used method to detect and visualize those latent fingerprints is to peel off each layer of the tapes first and then adopt the chemical methods to develop the fingerprints on the tapes. However, the peeling-off and chemical development process would degrade and contaminate the fingerprints and thus adversely affect the accuracy of identification. Optical coherence tomography (OCT) is a novel forensic imaging modality based on lowcoherence interferometry, which has the advantages of non-destruction, micrometer-level high resolution and crosssectional imaging. In this study, a fiber-based spectral-domain OCT (SD-OCT) system with {6μm resolution was employed to obtain the image of fingerprint sandwiched between two opaque electrical tapes without any pre-processing procedure like peeling-off. Three-dimensional (3D) OCT reconstruction was performed and the subsurface image was produced to visualize the latent fingerprints. The results demonstrate that OCT is a promising tool for recovering the latent fingerprints hidden beneath opaque electrical tape non-destructively and rapidly.

  7. Thermomechanical Analysis of Shape-Memory Composite Tape Spring

    NASA Astrophysics Data System (ADS)

    Yang, H.; Wang, L. Y.

    2013-06-01

    Intelligent materials and structures have been extensively applied for satellite designs in order to minimize the mass and reduce the cost in the launch of the spacecraft. Elastic memory composites (EMCs) have the ability of high-strain packaging and shape-memory effect, but increase the parts and total weight due to the additional heating system. Shape-memory sandwich structures Li and Wang (J. Intell. Mater. Syst. Struct. 22(14), 1605-1612, 2011) can overcome such disadvantage by using the metal skin acting as the heating element. However, the high strain in the micro-buckled metal skin decreases the deployment efficiency. This paper aims to present an insight into the folding and deployment behaviors of shape-memory composite (SMC) tape springs. A thermomechanical process was analyzed, including the packaging deformation at an elevated temperature, shape frozen at the low temperature and shape recovery after reheating. The result shows that SMC tape springs can significantly decrease the strain concentration in the metal skin, as well as exhibiting excellent shape frozen and recovery behaviors. Additionally, possible failure modes of SMC tape springs were also analyzed.

  8. A Game Map Complexity Measure Based on Hamming Distance

    NASA Astrophysics Data System (ADS)

    Li, Yan; Su, Pan; Li, Wenliang

    With the booming of PC game market, Game AI has attracted more and more researches. The interesting and difficulty of a game are relative with the map used in game scenarios. Besides, the path-finding efficiency in a game is also impacted by the complexity of the used map. In this paper, a novel complexity measure based on Hamming distance, called the Hamming complexity, is introduced. This measure is able to estimate the complexity of binary tileworld. We experimentally demonstrated that Hamming complexity is highly relative with the efficiency of A* algorithm, and therefore it is a useful reference to the designer when developing a game map.

  9. Distance measures and optimization spaces in quantitative fatty acid signature analysis

    USGS Publications Warehouse

    Bromaghin, Jeffrey F.; Rode, Karyn D.; Budge, Suzanne M.; Thiemann, Gregory W.

    2015-01-01

    Quantitative fatty acid signature analysis has become an important method of diet estimation in ecology, especially marine ecology. Controlled feeding trials to validate the method and estimate the calibration coefficients necessary to account for differential metabolism of individual fatty acids have been conducted with several species from diverse taxa. However, research into potential refinements of the estimation method has been limited. We compared the performance of the original method of estimating diet composition with that of five variants based on different combinations of distance measures and calibration-coefficient transformations between prey and predator fatty acid signature spaces. Fatty acid signatures of pseudopredators were constructed using known diet mixtures of two prey data sets previously used to estimate the diets of polar bears Ursus maritimus and gray seals Halichoerus grypus, and their diets were then estimated using all six variants. In addition, previously published diets of Chukchi Sea polar bears were re-estimated using all six methods. Our findings reveal that the selection of an estimation method can meaningfully influence estimates of diet composition. Among the pseudopredator results, which allowed evaluation of bias and precision, differences in estimator performance were rarely large, and no one estimator was universally preferred, although estimators based on the Aitchison distance measure tended to have modestly superior properties compared to estimators based on the Kullback-Leibler distance measure. However, greater differences were observed among estimated polar bear diets, most likely due to differential estimator sensitivity to assumption violations. Our results, particularly the polar bear example, suggest that additional research into estimator performance and model diagnostics is warranted.

  10. VIEW OF CABLES AND TAPES ASSOCIATED WITH ADRIVE CONTROL ROD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF CABLES AND TAPES ASSOCIATED WITH A-DRIVE CONTROL ROD SYSTEM, AT LEVEL +15’, DIRECTLY ABOVE PDP CONTROL ROOM, LOOKING NORTHWEST. THE CABLES FROM THE PDP ROOM GO THROUGH THE CONCRETE WALL, MAKE A RIGHT ANGLE TURN DOWNWARD, AND DESCEND INTO THE PDP CONTROL ROOM AS VERTICAL TAPES - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  11. Distance measurements from supernovae and dark energy constraints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang Yun

    2009-12-15

    Constraints on dark energy from current observational data are sensitive to how distances are measured from Type Ia supernova (SN Ia) data. We find that flux averaging of SNe Ia can be used to test the presence of unknown systematic uncertainties, and yield more robust distance measurements from SNe Ia. We have applied this approach to the nearby+SDSS+ESSENCE+SNLS+HST set of 288 SNe Ia, and the 'Constitution' set of 397 SNe Ia. Combining the SN Ia data with cosmic microwave background anisotropy data from Wilkinson Microwave Anisotropy Probe 5 yr observations, the Sloan Digital Sky Survey baryon acoustic oscillation measurements, themore » data of 69 gamma-ray bursts (GRBs) , and the Hubble constant measurement from the Hubble Space Telescope project SHOES, we measure the dark energy density function X(z){identical_to}{rho}{sub X}(z)/{rho}{sub X}(0) as a free function of redshift (assumed to be a constant at z>1 or z>1.5). Without the flux averaging of SNe Ia, the combined data using the Constitution set of SNe Ia seem to indicate a deviation from a cosmological constant at {approx}95% confidence level at 0 < or apporx. z < or approx. 0.8; they are consistent with a cosmological constant at {approx}68% confidence level when SNe Ia are flux averaged. The combined data using the nearby+SDSS+ESSENCE+SNLS+HST data set of SNe Ia are consistent with a cosmological constant at 68% confidence level with or without flux averaging of SNe Ia, and give dark energy constraints that are significantly more stringent than that using the Constitution set of SNe Ia. Assuming a flat Universe, dark energy is detected at >98% confidence level for z{<=}0.75 using the combined data with 288 SNe Ia from nearby+SDSS+ESSENCE+SNLS+HST, independent of the assumptions about X(z{>=}1). We quantify dark energy constraints without assuming a flat Universe using the dark energy figure of merit for both X(z) and a dark energy equation-of-state linear in the cosmic scale factor.« less

  12. Pilot study: Investigating the effects of Kinesio Taping® on functional activities in children with cerebral palsy.

    PubMed

    da Costa, Carolina Souza Neves; Rodrigues, Fernanda Simioni; Leal, Fernanda Mustafe; Rocha, Nelci Adriana Cicuto Ferreira

    2013-01-01

    To investigate the immediate effects of Kinesio Taping® (KT) on sit-to-stand (STS) movement, balance and dynamic postural control in children with cerebral palsy (CP). Four children diagnosed with left hemiplegic CP level I by the Gross Motor Function Classification System were evaluated under conditions without taping as control condition (CC); and with KT as kinesio condition. A motion analysis system was used to measure total duration of STS movement and angular movements of each joint. Clinical instruments such as Pediatric Balance Scale (PBS) and Timed up and Go (TUG) were also applied. Compared to CC, decreased total duration of STS, lower peak ankle flexion, higher knee extension at the end of STS, and decreased total time in TUG; but no differences were obtained on PBS score in KT. Neuromuscular taping seems to be beneficial on dynamic activities, but not have the same performance in predominantly static activities studied.

  13. Lifetime measurements using the recoil distance method—achievements and perspectives

    NASA Astrophysics Data System (ADS)

    Krücken, R.

    2001-07-01

    The recoil distance method (RDM) for measuring pico-second nuclear level lifetimes and its use in nuclear structure studies is reviewed and perspectives for the future are presented. High precision measurements in the mass-130 region, studies of multi-phonon states in rare earth nuclei, the investigation of shape coexistence and the recently discovered phenomenon of "magnetic rotation" are reviewed. Prospects for lifetime measurements in exotic regions of nuclei such as the measurement of lifetimes in neutron rich nuclei populated via spontaneous and heavy-ion induced fission are discussed. Other prospects include the use of the RDM technique in conjunction with recoil separators. The relevance of these techniques for experiments with radioactive ion beams will be discussed.

  14. Experimental Analysis of Critical Current and Alternating Current Losses of High-Temperature Superconductor Tape with Resin and Gallium-Indium-Tin

    PubMed Central

    Sun, Yajie; Zhang, Huiming; Meng, Yuanzhu

    2018-01-01

    This paper experimentally analyzes the critical current degradation and AC (alternating current) losses of second-generation (2G) high-temperature superconductor (HTS) tape during the impregnation process. Two impregnation materials were utilized: Gallium-Indium-Tin (GaInSn), and an epoxy resin, Araldite. The critical current of the impregnation materials was measured after different thermal cycles and compared with the tape with no impregnation process. The experimental results show that the critical current of Yttrium Barium Copper Oxide (YBCO) short samples varies between differently impregnated materials. The resin, Araldite, degraded the critical current; however, the GaInSn showed no degradation. Two degradation patterns with Araldite were identified due to the impregnation process, and the corresponding causes were analyzed. We further measured the AC losses of tapes impregnated with liquid metal at different frequencies, up to 600 Hz. Based on the experimental results, GaInSn liquid metal should be the most suitable impregnation material in terms of critical current degradation. PMID:29642490

  15. Experimental Analysis of Critical Current and Alternating Current Losses of High-Temperature Superconductor Tape with Resin and Gallium-Indium-Tin.

    PubMed

    Yu, Dongmin; Sun, Yajie; Zhang, Huiming; Meng, Yuanzhu; Liu, Huanan

    2018-04-08

    This paper experimentally analyzes the critical current degradation and AC (alternating current) losses of second-generation (2G) high-temperature superconductor (HTS) tape during the impregnation process. Two impregnation materials were utilized: Gallium-Indium-Tin (GaInSn), and an epoxy resin, Araldite. The critical current of the impregnation materials was measured after different thermal cycles and compared with the tape with no impregnation process. The experimental results show that the critical current of Yttrium Barium Copper Oxide (YBCO) short samples varies between differently impregnated materials. The resin, Araldite, degraded the critical current; however, the GaInSn showed no degradation. Two degradation patterns with Araldite were identified due to the impregnation process, and the corresponding causes were analyzed. We further measured the AC losses of tapes impregnated with liquid metal at different frequencies, up to 600 Hz. Based on the experimental results, GaInSn liquid metal should be the most suitable impregnation material in terms of critical current degradation.

  16. Amplitude spectrum distance: measuring the global shape divergence of protein fragments.

    PubMed

    Galiez, Clovis; Coste, François

    2015-08-14

    In structural bioinformatics, there is an increasing interest in identifying and understanding the evolution of local protein structures regarded as key structural or functional protein building blocks. A central need is then to compare these, possibly short, fragments by measuring efficiently and accurately their (dis)similarity. Progress towards this goal has given rise to scores enabling to assess the strong similarity of fragments. Yet, there is still a lack of more progressive scores, with meaningful intermediate values, for the comparison, retrieval or clustering of distantly related fragments. We introduce here the Amplitude Spectrum Distance (ASD), a novel way of comparing protein fragments based on the discrete Fourier transform of their C(α) distance matrix. Defined as the distance between their amplitude spectra, ASD can be computed efficiently and provides a parameter-free measure of the global shape dissimilarity of two fragments. ASD inherits from nice theoretical properties, making it tolerant to shifts, insertions, deletions, circular permutations or sequence reversals while satisfying the triangle inequality. The practical interest of ASD with respect to RMSD, RMSDd, BC and TM scores is illustrated through zinc finger retrieval experiments and concrete structure examples. The benefits of ASD are also illustrated by two additional clustering experiments: domain linkers fragments and complementarity-determining regions of antibodies. Taking advantage of the Fourier transform to compare fragments at a global shape level, ASD is an objective and progressive measure taking into account the whole fragments. Its practical computation time and its properties make ASD particularly relevant for applications requiring meaningful measures on distantly related protein fragments, such as similar fragments retrieval asking for high recalls as shown in the experiments, or for any application taking also advantage of triangle inequality, such as fragments

  17. Effect of fatigue loading on critical current in stainless steel-laminated DI-BSCCO superconducting composite tape

    NASA Astrophysics Data System (ADS)

    Hojo, M.; Osawa, K.; Adachi, T.; Inoue, Y.; Osamura, K.; Ochiai, S.; Ayai, N.; Hayashi, K.

    2010-11-01

    Tensile strain tolerance of the critical current in (Bi,Pb)2Sr2Ca2Cu3Ox (Bi2223) composite superconductor is dramatically improved when the tape is laminated with stainless steel. For practical applications, it is important to understand whether this reinforcement by lamination is effective under fatigue loading. In the present study, we carried out fatigue tests in LN2 and measured the critical current at the specific fatigue cycles to clarify the strain tolerance of the critical current in stainless steel-laminated drastically innovative Bi2223 (DI-BSCCO®) tapes. The fatigue tests were carried out using a computer-controlled 10 kN servo-hydraulic fatigue testing machine with a load cell capacity of 2.5 kN. Tests under static loading showed that the irreversible stress at which the critical current is reduced by 1% from the original value (tensile stress at Ic/Ic0 = 0.99) was 315 MPa when measured at unloading state. The present fatigue tests results indicated that the critical current was maintained at over 98% of the original value at unloading state after stress cycles of 106 when the static irreversible stress was selected as the maximum stress under fatigue loading. Thus, laminated DI-BSCCO tapes showed excellent mechanical properties even under fatigue loading.

  18. The Hetu'u Global Network: Measuring the Distance to the Sun with the Transit of Venus

    NASA Astrophysics Data System (ADS)

    Rodriguez, David; Faherty, J.

    2013-01-01

    In the spirit of historic astronomical endeavors, we invited school groups across the globe to collaborate in a solar distance measurement using the 2012 transit of Venus. In total, our group (stationed at Easter Island, Chile) recruited 19 school groups spread over 6 continents and 10 countries to participate in our Hetu’u Global Network. Applying the methods of French astronomer Joseph-Nicolas Delisle, we used individual second and third Venus-Sun contact times to calculate the distance to the Sun. Ten of the sites in our network had amiable weather; 8 of which measured second contact and 5 of which measured third contact leading to consistent solar distance measurements of 152+/-30 million km and 163+/-30 million km respectively. The distance to the Sun at the time of the transit was 152.25 million km; therefore, our measurements are also consistent within 1-sigma of the known value. The goal of our international school group network was to inspire the next generation of scientists using the excitement and accessibility of such a rare astronomical event. In the process, we connected hundreds of participating students representing a diverse, multi-cultural group with differing political, economic, and racial backgrounds.

  19. User's guide to the UTIL-ODRC tape processing program. [for the Orbital Data Reduction Center

    NASA Technical Reports Server (NTRS)

    Juba, S. M. (Principal Investigator)

    1981-01-01

    The UTIL-ODRC computer compatible tape processing program, its input/output requirements, and its interface with the EXEC 8 operating system are described. It is a multipurpose orbital data reduction center (ODRC) tape processing program enabling the user to create either exact duplicate tapes and/or tapes in SINDA/HISTRY format. Input data elements for PRAMPT/FLOPLT and/or BATCH PLOT programs, a temperature summary, and a printed summary can also be produced.

  20. Kinesio taping in musculoskeletal pain and disability that lasts for more than 4 weeks: is it time to peel off the tape and throw it out with the sweat? A systematic review with meta-analysis focused on pain and also methods of tape application.

    PubMed

    Lim, Edwin Choon Wyn; Tay, Mathew Guo Xiang

    2015-12-01

    In recent years, Kinesio tape has been used to support injured muscle and joints, and relieve pain. We compared the pain and disability in individuals with chronic musculoskeletal pain who were treated with Kinesio taping with those using minimal or other treatment approaches. Searches of eight major electronic databases were conducted. Data for pain and disability scores were extracted. Meta-analyses (wherever possible) with either a fixed or random effect(s) model, standardised mean differences (SMDs) and tests of heterogeneity were performed. Seventeen clinical-controlled trials were identified and included in the meta-analyses. When compared to minimal intervention, Kinesio taping provided superior pain relief (pooled SMD=-0.36, 95% CI -0.64 to -0.09, p=0.009) but the pooled disability scores were not significantly different (pooled SMD=-0.41, 95% CI -0.83 to 0.01, p=0.05). No significant differences were found when comparing Kinesio taping to other treatment approaches for pain (pooled SMD=-0.44, 95% CI -1.69 to 0.82, p=0.49) and disability (pooled SMD=0.08, 95% CI -0.27 to 0.43, p=0.65). Kinesio taping is superior to minimal intervention for pain relief. Existing evidence does not establish the superiority of Kinesio taping to other treatment approaches to reduce pain and disability for individuals with chronic musculoskeletal pain. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. Distance measurements in Au nanoparticles functionalized with nitroxide radicals and Gd(3+)-DTPA chelate complexes.

    PubMed

    Yulikov, Maxim; Lueders, Petra; Warsi, Muhammad Farooq; Chechik, Victor; Jeschke, Gunnar

    2012-08-14

    Nanosized gold particles were functionalised with two types of paramagnetic surface tags, one having a nitroxide radical and the other one carrying a DTPA complex loaded with Gd(3+). Selective measurements of nitroxide-nitroxide, Gd(3+)-nitroxide and Gd(3+)-Gd(3+) distances were performed on this system and information on the distance distribution in the three types of spin pairs was obtained. A numerical analysis of the dipolar frequency distributions is presented for Gd(3+) centres with moderate magnitudes of zero-field splitting, in the range of detection frequencies and resonance fields where the high-field approximation is only roughly valid. The dipolar frequency analysis confirms the applicability of DEER for distance measurements in such complexes and gives an estimate for the magnitudes of possible systematic errors due to the non-ideality of the measurement of the dipole-dipole interaction.

  2. 36 CFR 1275.64 - Reproduction of tape recordings of Presidential conversations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Reproduction of tape... § 1275.64 Reproduction of tape recordings of Presidential conversations. (a) To ensure the preservation... locations established by the Archivist in accordance with § 1275.62. (d) The reproduction for members of the...

  3. 36 CFR 1275.64 - Reproduction of tape recordings of Presidential conversations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Reproduction of tape... § 1275.64 Reproduction of tape recordings of Presidential conversations. (a) To ensure the preservation... locations established by the Archivist in accordance with § 1275.62. (d) The reproduction for members of the...

  4. Design study for multi-channel tape recorder system, volume 1

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The means of storing multispectral, high resolution sensor data on an Earth observing satellite are studied. It is concluded that this is best done digitally on a multi-track, longitudinal, magnetic tape recorder. The machine proposed will store 8 X 10 to the 10th power bits of data on 1040 m of 51 mm-wide magnetic tape mounted on two co-planar reels.

  5. Recoil distance method lifetime measurements at TRIUMF-ISAC using the TIGRESS Integrated Plunger

    NASA Astrophysics Data System (ADS)

    Chester, A.; Ball, G. C.; Bernier, N.; Cross, D. S.; Domingo, T.; Drake, T. E.; Evitts, L. J.; Garcia, F. H.; Garnsworthy, A. B.; Hackman, G.; Hallam, S.; Henderson, J.; Henderson, R.; Krücken, R.; MacConnachie, E.; Moukaddam, M.; Padilla-Rodal, E.; Paetkau, O.; Pore, J. L.; Rizwan, U.; Ruotsalainen, P.; Shoults, J.; Smallcombe, J.; Smith, J. K.; Starosta, K.; Svensson, C. E.; Van Wieren, K.; Williams, J.; Williams, M.

    2018-02-01

    The TIGRESS Integrated Plunger device (TIP) has been developed for recoil distance method (RDM) lifetime measurements using the TIGRESS array of HPGe γ-ray detectors at TRIUMF's ISAC-II facility. A commissioning experiment was conducted utilizing a 250 MeV 84Kr beam at ≈ 2 × 108 particles per second. The 84Kr beam was Coulomb excited to the 21+ state on a movable 27Al target. A thin Cu foil fixed downstream from the target was used as a degrader. Excited nuclei emerged from the target and decayed by γ-ray emission at a distance determined by their velocity and the lifetime of the 21+ state. The ratio of decays which occur between the target and degrader to those occurring after traversing the degrader changes as a function of the target-degrader separation distance. Gamma-ray spectra at 13 target-degrader separation distances were measured and compared to simulated lineshapes to extract the lifetime. The result of τ = 5 . 541 ± 0 . 013(stat.) ± 0 . 063(sys.) ps is shorter than the literature value of 5 . 84 ± 0 . 18 ps with a reduction in uncertainty by a factor of approximately two. The TIP plunger device, experimental technique, analysis tools, and result are discussed.

  6. Neutron and gamma-ray dose measurements at various distances from the Little Boy replica

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huntzinger, C.J.; Hankins, D.E.

    We measured neutron and gamma-ray dose rates at various distances from the Little Boy-Comet Critical Assembly at Los Alamos National Laboratory (LANL) in April of 1983. The Little Boy-Comet Assembly is a replica of the atomic weapon detonated over Hiroshima, designed to be operated at various steady-state power levels. The selected distances for measurement ranged from 107 m to 567 m. Gamma-ray measurements were made with a Reuter-Stokes environmental ionization chamber which has a sensitivity of 1.0 ..mu..R/hour. Neutron measurements were made with a pulsed-source remmeter which has a sensitivity of 0.1 ..mu..rem/hour, designed and built at Lawrence Livermore Nationalmore » Laboratory (LLNL). 12 references, 7 figures, 6 tables.« less

  7. The Cost of Distance Education. IEC Broadsheets on Distance Learning No. 17.

    ERIC Educational Resources Information Center

    Perraton, Hilary

    One of a series offering practical advice and information on distance teaching, this broadsheet first looks at the reasons for trying to measure distance teaching costs and the methodological and economic difficulties involved in such measurements. Broadcasting and print costs in distance teaching are discussed, and evidence about the costs of…

  8. High rate of vaginal erosions associated with the mentor ObTape.

    PubMed

    Yamada, Brian S; Govier, Fred E; Stefanovic, Ksenija B; Kobashi, Kathleen C

    2006-08-01

    The transobturator tape method is a newer surgical technique for the treatment of stress urinary incontinence. Limited data exist related to complications with this approach or the types of mesh products used. We report our experience with vaginal erosions associated with the Mentor ObTape and American Medical Systems Monarc transobturator slings. Beginning in December 2003 selected female patients with anatomic urinary incontinence were prospectively followed after placement of the Mentor ObTape. Beginning in January 2004 we also began using the American Medical Systems Monarc in similar patients. Patients were admitted overnight after surgery, discharged on oral antibiotics, and seen in the clinic at 6 weeks postoperatively. A total of 67 patients have undergone placement of the Mentor ObTape and 9 of those patients (13.4%) have had vaginal extrusions of the sling. Eight patients reported a history of persistent vaginal discharge. One patient presented initially to an outside facility with a left thigh abscess tracking to the left inguinal incision site. Each patient was taken back to the operating room for mesh removal. A total of 56 patients have undergone placement of the AMS Monarc and none have had any vaginal erosions. Our high rate of vaginal extrusion using the ObTape has led us to discontinue the use of this product in our institution. Continued followup of all of these patients will be of critical importance.

  9. Quantifying Similarity and Distance Measures for Vector-Based Datasets: Histograms, Signals, and Probability Distribution Functions

    DTIC Science & Technology

    2017-02-01

    note, a number of different measures implemented in both MATLAB and Python as functions are used to quantify similarity/distance between 2 vector-based...this technical note are widely used and may have an important role when computing the distance and similarity of large datasets and when considering high...throughput processes. In this technical note, a number of different measures implemented in both MAT- LAB and Python as functions are used to

  10. High Fidelity Tape Transfer Printing Based On Chemically Induced Adhesive Strength Modulation

    NASA Astrophysics Data System (ADS)

    Sim, Kyoseung; Chen, Song; Li, Yuhang; Kammoun, Mejdi; Peng, Yun; Xu, Minwei; Gao, Yang; Song, Jizhou; Zhang, Yingchun; Ardebili, Haleh; Yu, Cunjiang

    2015-11-01

    Transfer printing, a two-step process (i.e. picking up and printing) for heterogeneous integration, has been widely exploited for the fabrication of functional electronics system. To ensure a reliable process, strong adhesion for picking up and weak or no adhesion for printing are required. However, it is challenging to meet the requirements of switchable stamp adhesion. Here we introduce a simple, high fidelity process, namely tape transfer printing(TTP), enabled by chemically induced dramatic modulation in tape adhesive strength. We describe the working mechanism of the adhesion modulation that governs this process and demonstrate the method by high fidelity tape transfer printing several types of materials and devices, including Si pellets arrays, photodetector arrays, and electromyography (EMG) sensors, from their preparation substrates to various alien substrates. High fidelity tape transfer printing of components onto curvilinear surfaces is also illustrated.

  11. Multi-Response Parameter Interval Sensitivity and Optimization for the Composite Tape Winding Process.

    PubMed

    Deng, Bo; Shi, Yaoyao; Yu, Tao; Kang, Chao; Zhao, Pan

    2018-01-31

    The composite tape winding process, which utilizes a tape winding machine and prepreg tapes, provides a promising way to improve the quality of composite products. Nevertheless, the process parameters of composite tape winding have crucial effects on the tensile strength and void content, which are closely related to the performances of the winding products. In this article, two different object values of winding products, including mechanical performance (tensile strength) and a physical property (void content), were respectively calculated. Thereafter, the paper presents an integrated methodology by combining multi-parameter relative sensitivity analysis and single-parameter sensitivity analysis to obtain the optimal intervals of the composite tape winding process. First, the global multi-parameter sensitivity analysis method was applied to investigate the sensitivity of each parameter in the tape winding processing. Then, the local single-parameter sensitivity analysis method was employed to calculate the sensitivity of a single parameter within the corresponding range. Finally, the stability and instability ranges of each parameter were distinguished. Meanwhile, the authors optimized the process parameter ranges and provided comprehensive optimized intervals of the winding parameters. The verification test validated that the optimized intervals of the process parameters were reliable and stable for winding products manufacturing.

  12. Multi-Response Parameter Interval Sensitivity and Optimization for the Composite Tape Winding Process

    PubMed Central

    Yu, Tao; Kang, Chao; Zhao, Pan

    2018-01-01

    The composite tape winding process, which utilizes a tape winding machine and prepreg tapes, provides a promising way to improve the quality of composite products. Nevertheless, the process parameters of composite tape winding have crucial effects on the tensile strength and void content, which are closely related to the performances of the winding products. In this article, two different object values of winding products, including mechanical performance (tensile strength) and a physical property (void content), were respectively calculated. Thereafter, the paper presents an integrated methodology by combining multi-parameter relative sensitivity analysis and single-parameter sensitivity analysis to obtain the optimal intervals of the composite tape winding process. First, the global multi-parameter sensitivity analysis method was applied to investigate the sensitivity of each parameter in the tape winding processing. Then, the local single-parameter sensitivity analysis method was employed to calculate the sensitivity of a single parameter within the corresponding range. Finally, the stability and instability ranges of each parameter were distinguished. Meanwhile, the authors optimized the process parameter ranges and provided comprehensive optimized intervals of the winding parameters. The verification test validated that the optimized intervals of the process parameters were reliable and stable for winding products manufacturing. PMID:29385048

  13. Generic tags for Mn(ii) and Gd(iii) spin labels for distance measurements in proteins.

    PubMed

    Yang, Yin; Gong, Yan-Jun; Litvinov, Aleksei; Liu, Hong-Kai; Yang, Feng; Su, Xun-Cheng; Goldfarb, Daniella

    2017-10-11

    High-affinity chelating tags for Gd(iii) and Mn(ii) ions that provide valuable high-resolution distance restraints for biomolecules were used as spin labels for double electron-electron resonance (DEER) measurements. The availability of a generic tag that can bind both metal ions and provide a narrow and predictable distance distribution for both ions is attractive owing to their different EPR-related characteristics. Herein we introduced two paramagnetic tags, 4PSPyMTA and 4PSPyNPDA, which are conjugated to cysteine residues through a stable thioether bond, forming a short and, depending on the metal ion coordination mode, a rigid tether with the protein. These tags exhibit high affinity for both Mn(ii) and Gd(iii) ions. The DEER performance of the 4PSPyMTA and 4PSPyNPDA tags, in complex with Gd(iii) or Mn(ii), was evaluated for three double cysteine mutants of ubiquitin, and the Gd(iii)-Gd(iii) and Mn(ii)-Mn(ii) distance distributions they generated were compared. All three Gd(iii) complexes of the ubiquitin-PyMTA and ubiquitin-PyNPDA conjugates produced similar and expected distance distributions. In contrast, significant variations in the maxima and widths of the distance distributions were observed for the Mn(ii) analogs. Furthermore, whereas PyNPDA-Gd(iii) and PyNPDA-Mn(ii) delivered similar distance distributions, appreciable differences were observed for two mutants with PyMTA, with the Mn(ii) analog exhibiting a broader distance distribution and shorter distances. ELDOR (electron-electron double resonance)-detected NMR measurements revealed some distribution in the Mn(ii) coordination environment for the protein conjugates of both tags but not for the free tags. The broader distance distributions generated by 4PSPyMTA-Mn(ii), as compared with Gd(iii), were attributed to the distributed location of the Mn(ii) ion within the PyMTA chelate owing to its smaller size and lower coordination number that leave the pyridine nitrogen uncoordinated. Accordingly, in

  14. Laser fresnel distance measuring system and method

    NASA Technical Reports Server (NTRS)

    Campbell, Jonathan W. (Inventor); Lehner, David L. (Inventor); Smalley, Larry L. (Inventor); Smith, legal representative, Molly C. (Inventor); Sanders, Alvin J. (Inventor); Earl, Dennis Duncan (Inventor); Allison, Stephen W. (Inventor); Smith, Kelly L. (Inventor)

    2008-01-01

    A method and system for determining range to a target are provided. A beam of electromagnetic energy is transmitted through an aperture in an opaque screen such that a portion of the beam passes through the aperture to generate a region of diffraction that varies as a function of distance from the aperture. An imaging system is focused on a target plane in the region of diffraction with the generated image being compared to known diffraction patterns. Each known diffraction pattern has a unique value associated therewith that is indicative of a distance from the aperture. A match between the generated image and at least one of the known diffraction patterns is indicative of a distance between the aperture and target plane.

  15. Niobium-germanium superconducting tapes for high-field magnet applications

    NASA Technical Reports Server (NTRS)

    Braginski, A. I.; Roland, G. W.; Daniel, M. R.; Woolam, J. A.

    1977-01-01

    A process of fabricating superconducting Nb3Ge tapes by chemical vapor deposition (CVD) has been developed and tapes up to 10 meters long fabricated. The typical properties achieved were: critical temperature T sub c = 20 K, upper critical field H sub c2 = 29 tesla at 4.2 K, and J sub c = 3 to 4 x 10 to the 8th power A m(-2) at 4.2 K, 18 tesla. The relative depression of T sub c and H sub c2 compared with the best thin film samples sputtered on sapphire was due to the presence of Nb5Ge3 second-phase particles used as flux pinning centers and to strains induced by thermal mixmatch with Hastelloy B tape substrates. A peculiar field dependence of flux pinning force that was observed in both CVD and sputtered Nb3Ge indicated a premature pin-breaking mechanism or a phase inhomogeneity. Directions of further optimization work were defined.

  16. Phase-slope and phase measurements of tunable CW-THz radiation with terahertz comb for wide-dynamic-range, high-resolution, distance measurement of optically rough object.

    PubMed

    Yasui, Takeshi; Fujio, Makoto; Yokoyama, Shuko; Araki, Tsutomu

    2014-07-14

    Phase measurement of continuous-wave terahertz (CW-THz) radiation is a potential tool for direct distance and imaging measurement of optically rough objects due to its high robustness to optical rough surfaces. However, the 2π phase ambiguity in the phase measurement of single-frequency CW-THz radiation limits the dynamic range of the measured distance to the order of the wavelength used. In this article, phase-slope measurement of tunable CW-THz radiation with a THz frequency comb was effectively used to extend the dynamic range up to 1.834 m while maintaining an error of a few tens µm in the distance measurement of an optically rough object. Furthermore, a combination of phase-slope measurement of tunable CW-THz radiation and phase measurement of single-frequency CW-THz radiation enhanced the distance error to a few µm within the dynamic range of 1.834 m without any influence from the 2π phase ambiguity. The proposed method will be a powerful tool for the construction and maintenance of large-scale structures covered with optically rough surfaces.

  17. Measuring distance “as the horse runs”: Cross-scale comparison of terrain-based metrics

    USGS Publications Warehouse

    Buttenfield, Barbara P.; Ghandehari, M; Leyk, S; Stanislawski, Larry V.; Brantley, M E; Qiang, Yi

    2016-01-01

    Distance metrics play significant roles in spatial modeling tasks, such as flood inundation (Tucker and Hancock 2010), stream extraction (Stanislawski et al. 2015), power line routing (Kiessling et al. 2003) and analysis of surface pollutants such as nitrogen (Harms et al. 2009). Avalanche risk is based on slope, aspect, and curvature, all directly computed from distance metrics (Gutiérrez 2012). Distance metrics anchor variogram analysis, kernel estimation, and spatial interpolation (Cressie 1993). Several approaches are employed to measure distance. Planar metrics measure straight line distance between two points (“as the crow flies”) and are simple and intuitive, but suffer from uncertainties. Planar metrics assume that Digital Elevation Model (DEM) pixels are rigid and flat, as tiny facets of ceramic tile approximating a continuous terrain surface. In truth, terrain can bend, twist and undulate within each pixel.Work with Light Detection and Ranging (lidar) data or High Resolution Topography to achieve precise measurements present challenges, as filtering can eliminate or distort significant features (Passalacqua et al. 2015). The current availability of lidar data is far from comprehensive in developed nations, and non-existent in many rural and undeveloped regions. Notwithstanding computational advances, distance estimation on DEMs has never been systematically assessed, due to assumptions that improvements are so small that surface adjustment is unwarranted. For individual pixels inaccuracies may be small, but additive effects can propagate dramatically, especially in regional models (e.g., disaster evacuation) or global models (e.g., sea level rise) where pixels span dozens to hundreds of kilometers (Usery et al 2003). Such models are increasingly common, lending compelling reasons to understand shortcomings in the use of planar distance metrics. Researchers have studied curvature-based terrain modeling. Jenny et al. (2011) use curvature to generate

  18. THE EFFECTS OF VIDEO-TAPING PROCEDURES IN AN EXPERIMENTAL READING PROGRAM.

    ERIC Educational Resources Information Center

    SCHWARTZ-LITTMANN, CAROLE

    THE EXPERIMENTAL USE OF VIDEO AND TAPE RECORDINGS IN TEACHING THREE NEUROLOGICALLY DISABLED BOYS AGED 8, 9, AND 10 TO READ IS REPORTED. EXPERIENCE CHARTS WERE USED TO PRESENT BOTH UNCONTROLLED AND CONTROLLED VOCABULARY. THREE SPACES VIDEO-TAPED DEMONSTRATIONS WITH THE CHILDREN WERE USED TO DIAGNOSE PROGRESS AND AS MOTIVATIONAL DEVICES. THE…

  19. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 1 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 1 through 3. The activities from other flight days can be seen on 'STS 109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), 'STS 109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139471), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). The main activity recorded during flight day 1 is the liftoff of Columbia. Attention is given to suit-up, boarding, and pre-flight procedures. The pre-launch crew meal has no sound. The crew members often wave to the camera before liftoff. The jettisoning of the solid rocket boosters is shown, and the External Tank is seen as it falls to Earth, moving over African dunes in the background. There are liftoff replays, including one from inside the cockpit. The opening of the payload bay doors is seen from the rear of the shuttle's cockpit. The footage from flight day 2 shows the Flight Support System for bearthing the HST (Hubble Space Telescope). Crew preparations for the bearthing are shown. Flight day 3 shows the tracking of and approach to the HST by Columbia, including orbital maneuvers, the capture of the HST, and its lowering onto the Flight Support System. Many views of the HST are shown, including one which reveals an ocean and cloud background as the HST retracts a solar array.

  20. Optimal compliance for amblyopia therapy: occlusion with a translucent tape on the lens.

    PubMed

    Beneish, Raquel G; Polomeno, Robert C; Flanders, Michael E; Koenekoop, Robert K

    2009-10-01

    To demonstrate that optimal compliance to amblyopia therapy and a better visual outcome can be achieved by occluding the lens over the preferred eye with a translucent tape. Prospective study of amblyopic children. Eighty-four amblyopic children recruited from 2000 to 2006 at the Montreal Children's Vision Centre. A group of bilateral ametropes (mean age 3.8 years) were treated with glasses and occlusion of the sound eye with a translucent tape on the lens over the preferred eye, or an adhesive patch. The translucent tape reduced vision to hand motion at 0.3 m in the sound eye. Patients were divided into 2 groups depending on the treatment received. Group 1 (n = 36) was occluded with a translucent tape, and group 2 (n = 48) with a conventional adhesive patch, later replaced by the translucent tape. Twenty-five previously reported patients, treated with the conventional adhesive patch only, were used as controls (group 3). The mean amblyopic visual acuity was 20/100-2. Compliance was good in 36 patients (group 1), and was poor or deteriorated in 24/48 patients (group 2). Substituting the adhesive patch with a translucent tape permitted uninterrupted and prolonged occlusion, with a successful visual outcome. The amblyopic eye achieved a significantly better final vision (20/30+2; groups 1+2) than the controls (20/40+1; group 3) (p = 0.04). Sixty-four (76.19%) patients achieved >or=20/30. The translucent tape optimizes compliance and yields better vision by lengthening the duration of occlusion therapy and reducing the number of treatment failures due to noncompliance.

  1. The effect of exercise and time on the height and width of the medial longitudinal arch following the modified reverse-6 and the modified augmented low-dye taping procedures.

    PubMed

    Cornwall, Mark W; McPoil, Thomas G; Fair, Austin

    2014-10-01

    No evidence exits regarding the magnitude of the change in foot posture following the "modified reverse-6" (MR6) taping procedure, either alone or in combination with the "low-dye" (LD) taping technique. The purpose of this study was to investigate the change in the height and width of the midfoot after application of the MR6 and the MR6 plus the LD (MR6+LD) taping technique and determine how long those changes last. Eleven individuals (2 female and 9 male) were recruited for this study and were tested under each of two experimental conditions, the MR6 and the MR6+LD taping technique. The order of testing for the two conditions was randomly determined. For each condition, the height and width of the midfoot at 50% of each subject's foot length was initially measured and then again immediately following the application of the tape. These measurements were repeated four hours later immediately prior to running two miles on a treadmill, again immediately after running, and finally after another four hours. The dorsal arch height increased significantly with both the MR6 and MR6+LD taping, but only the MR6+LD remained statistically greater after four hours, a bout of exercise and again at the end of the day. The mean width of the midfoot significantly decreased with both taping procedures. The change in the width of the midfoot remained significantly decreased in both taping conditions after exercise and throughout the day. Both taping procedures are able to significantly change the height and width of the medial longitudinal arch of the foot, but the change lasted longer when the two taping procedures were combined. Level 3, Prospective Cohort Study.

  2. "Space slitter" for film or tape

    NASA Technical Reports Server (NTRS)

    Johnson, W. H.

    1978-01-01

    Device cuts film or tape into strips by guiding film in channel under cutting blades. Device is operated by lifting pressure bar to insert blades into film. Film is then pulled through blades. Cutter has potential uses in advertising, commercial art, and publishing fields.

  3. Fundamental aspects of electric double layer force-distance measurements at liquid-solid interfaces using atomic force microscopy

    PubMed Central

    Black, Jennifer M.; Zhu, Mengyang; Zhang, Pengfei; Unocic, Raymond R.; Guo, Daqiang; Okatan, M. Baris; Dai, Sheng; Cummings, Peter T.; Kalinin, Sergei V.; Feng, Guang; Balke, Nina

    2016-01-01

    Atomic force microscopy (AFM) force-distance measurements are used to investigate the layered ion structure of Ionic Liquids (ILs) at the mica surface. The effects of various tip properties on the measured force profiles are examined and reveal that the measured ion position is independent of tip properties, while the tip radius affects the forces required to break through the ion layers as well as the adhesion force. Force data is collected for different ILs and directly compared with interfacial ion density profiles predicted by molecular dynamics. Through this comparison it is concluded that AFM force measurements are sensitive to the position of the ion with the larger volume and mass, suggesting that ion selectivity in force-distance measurements are related to excluded volume effects and not to electrostatic or chemical interactions between ions and AFM tip. The comparison also revealed that at distances greater than 1 nm the system maintains overall electroneutrality between the AFM tip and sample, while at smaller distances other forces (e.g., van der waals interactions) dominate and electroneutrality is no longer maintained. PMID:27587276

  4. Comparing the diagnostic properties of skin scraping, adhesive tape, and dermoscopy in diagnosing scabies.

    PubMed

    Abdel-Latif, Azmy A; Elshahed, Ahmad R; Salama, Omar A; Elsaie, Mohamed L

    2018-06-01

    Scabies is a contagious skin infestation that mainly presents with itching at night and skin burrows that are visible to the naked eye. Diagnosing scabies with dermoscopy is still a matter of controversy. The aim of our study was to compare the diagnostic properties of adhesive tape, skin scraping, and dermoscopy in diagnosing scabies. One hundred patients with clinical presumptive diagnoses of scabies underwent skin scraping, adhesive tape testing, and dermoscopic examination. Each diagnostic procedure was performed on three different areas. Comparing the diagnostic properties of the three methods, the adhesive tape test was the most sensitive method for diagnosing scabies. Sixteen cases (16.0%) were definitely diagnosed as scabies using the adhesive tape test detecting the presence of mites or their eggs. Only 10 cases (10.0%) were definitely diagnosed as scabies using the skin scraping test detecting mites or their eggs. Dermoscopic examination suggested a diagnosis of scabies in 22 cases (22.0%), of which only 10 were definitely diagnosed as scabies by detecting mites using the adhesive tape test, skin scraping, or both. The diagnosis of scabies can only be confirmed by seeing mites. The adhesive tape test and skin scraping procedure have high specificity in diagnosing scabies, but their low sensitivity cannot exclude the possibility of scabies. Dermoscopy-guided tape testing can be a helpful tool for better diagnosis of scabies.

  5. The Effect of Patellar Taping on Squat Depth and the Perception of Pain in People with Anterior Knee Pain

    PubMed Central

    Clifford, Amanda M.; Harrington, Elaine

    Patellar taping is a treatment adjunct commonly used in the management of anterior knee pain. The aim of this cross sectional study was to investigate the effects of medial glide patellar taping on sagittal plane lower-limb joint kinematics and knee pain during a unilateral squat in a symptomatic population complaining of anterior knee pain. Ten participants with a history of unilateral or bilateral anterior knee pain were included in the study. Subjects were required to squat on the symptomatic leg under three conditions: placebo tape, patellar tape and no tape. Kinematic data was recorded using the CODA mpx64 motion analysis system and subjects’ pain was assessed using the Numerical Rating Scale. Patellar taping resulted in a significantly greater single-legged squat depth compared to placebo tape (p=0.008) and no tape (p=0.001) and a statistically significant reduction in pain during a squat compared to placebo tape (p=0.001) or no tape (p=0.001). Significant differences were not identified for maximum knee flexion in the patella taping compared to the no tape condition. This study may have significant clinical implications as participants reported less pain and alterations in sagittal plane movement following the application of patellar tape. PMID:24146711

  6. Synchronisation Technique of Data Recorded on a Multichannel Tape Recorder,

    DTIC Science & Technology

    1984-01-01

    retrieval Synchronizers I 16. Abstract A portable, self-contained, electronic digital unit, termed Data Synchroniser was designed and developed by EDE...AD A139 570 SYNCHRONISATION TECHNIQUE OF DATA RECORDED ON A / OULl ICHANNEL TAPE RECORDER (U) ENGINEERING DEVELOPMENT ESTA B LISHMENT MARIBYRNONO...BGINEERING DEVELOPMEWIT ESTABUSHIMENT S[ SYNCHRONISATION TECHNIQUE OF DATA - i RECORDED ON A MULTICHANNEL TAPE RECORDER BY J.D. DICKENS .t T)TCi j.D. ~c .s

  7. Apparatus and method for loading and unloading multiple digital tape cassettes utilizing a removable magazine

    DOEpatents

    Lindenmeyer, C.W.

    1993-01-26

    An apparatus and method to automate the handling of multiple digital tape cassettes for processing by commercially available cassette tape readers and recorders. A removable magazine rack stores a plurality of tape cassettes, and cooperates with a shuttle device that automatically inserts and removes cassettes from the magazine to the reader and vice-versa. Photocells are used to identify and index to the desired tape cassette. The apparatus allows digital information stored on multiple cassettes to be processed without significant operator intervention.

  8. Apparatus and method for loading and unloading multiple digital tape cassettes utilizing a removable magazine

    DOEpatents

    Lindenmeyer, Carl W.

    1993-01-01

    An apparatus and method to automate the handling of multiple digital tape cassettes for processing by commercially available cassette tape readers and recorders. A removable magazine rack stores a plurality of tape cassettes, and cooperates with a shuttle device that automatically inserts and removes cassettes from the magazine to the reader and vice-versa. Photocells are used to identify and index to the desired tape cassette. The apparatus allows digital information stored on multiple cassettes to be processed without significant operator intervention.

  9. Censoring distances based on labeled cortical distance maps in cortical morphometry.

    PubMed

    Ceyhan, Elvan; Nishino, Tomoyuki; Alexopolous, Dimitrios; Todd, Richard D; Botteron, Kelly N; Miller, Michael I; Ratnanather, J Tilak

    2013-01-01

    It has been demonstrated that shape differences in cortical structures may be manifested in neuropsychiatric disorders. Such morphometric differences can be measured by labeled cortical distance mapping (LCDM) which characterizes the morphometry of the laminar cortical mantle of cortical structures. LCDM data consist of signed/labeled distances of gray matter (GM) voxels with respect to GM/white matter (WM) surface. Volumes and other summary measures for each subject and the pooled distances can help determine the morphometric differences between diagnostic groups, however they do not reveal all the morphometric information contained in LCDM distances. To extract more information from LCDM data, censoring of the pooled distances is introduced for each diagnostic group where the range of LCDM distances is partitioned at a fixed increment size; and at each censoring step, the distances not exceeding the censoring distance are kept. Censored LCDM distances inherit the advantages of the pooled distances but also provide information about the location of morphometric differences which cannot be obtained from the pooled distances. However, at each step, the censored distances aggregate, which might confound the results. The influence of data aggregation is investigated with an extensive Monte Carlo simulation analysis and it is demonstrated that this influence is negligible. As an illustrative example, GM of ventral medial prefrontal cortices (VMPFCs) of subjects with major depressive disorder (MDD), subjects at high risk (HR) of MDD, and healthy control (Ctrl) subjects are used. A significant reduction in laminar thickness of the VMPFC in MDD and HR subjects is observed compared to Ctrl subjects. Moreover, the GM LCDM distances (i.e., locations with respect to the GM/WM surface) for which these differences start to occur are determined. The methodology is also applicable to LCDM-based morphometric measures of other cortical structures affected by disease.

  10. Backscattering measurement of 6He on 209Bi: Critical interaction distance

    NASA Astrophysics Data System (ADS)

    Guimarães, V.; Kolata, J. J.; Aguilera, E. F.; Howard, A.; Roberts, A.; Becchetti, F. D.; Torres-Isea, R. O.; Riggins, A.; Febrarro, M.; Scarduelli, V.; de Faria, P. N.; Monteiro, D. S.; Huiza, J. F. P.; Arazi, A.; Hinnefeld, J.; Moro, A. M.; Rossi, E. S.; Morcelle, V.; Barioni, A.

    2016-06-01

    An elastic backscattering experiment has been performed at energies below the Coulomb barrier to investigate static and dynamic effects in the interaction of 6He with 209Bi. The measured cross sections are presented in terms of the d σ /d σR u t h ratio, as a function of the distance of closest approach on a Rutherford trajectory. The data are compared with a three-body CDCC calculation and good agreement is observed. In addition, the critical distance of interaction was extracted. A larger value was obtained for the exotic 6He nucleus as compared with the weakly bound 6Li and 9Be nuclei and the tightly bound 4He12C, and 16O nuclei.

  11. User's guide for the Nimbus 7 ERB Solar Analysis Tape (ESAT)

    NASA Technical Reports Server (NTRS)

    Hickey, J. R.; Major, E. R.; Kyle, H. L.

    1984-01-01

    Five years of Nimbus 7 ERB solar data is available in compact form on a single ERB solar analysis tape (ESAT). The period covered is November 16, 1978 through October 31, 1983. The Nimbus 7 satellite performs just under 14 orbits a day and the ERB solar telescope observe the Sun once per orbit as the satellite passes + or - near the south pole. The data were carefully calibrated and screened. Mean orbital and daily values are given for the total solar irradiance plus selected spectral intervals. In addition, selected solar activity indicators are on the tape. The ERB experiment, the solar data calibration and screening procedures, the solar activity indicators, and the tape format are described briefly.

  12. Measurement of g Using a Flashing LED

    NASA Astrophysics Data System (ADS)

    Terzella, T.; Sundermier, J.; Sinacore, J.; Owen, C.; Takai, H.

    2008-10-01

    In one of the classic free-fall experiments, a small mass is attached to a strip of paper tape and both are allowed to fall through a spark timer, where sparks are generated at regular time intervals. Students analyze marks (dots) left on the tape by the timer, thereby generating distance-versus-time data, which they analyze to extract the acceleration due to gravity g with good results. The apparatus, however, is cumbersome and often frustrating for students. High-tech versions of this experiment are done with an object dropped and followed by a motion sensor connected to a computer. The sensor relies on ultrasonic ranging to record distance and time data, which may then be displayed graphically. Students inspect the graphs to determine the value of g. Although the results are excellent, the emphasis on the computer's ability to collect and analyze data leaves little analysis for the students to perform.2 Furthermore, neither technique gives an intuitive display of what is happening. The motivation for our work was to overcome these issues by developing an innovative method for measuring g. In our version of the experiment, students drop a flashing LED at a known frequency and record its trajectory using long exposure photography with a digital camera. Proper choice of flashing LED timing parameters produces an image that allows for an accurate measurement of g and at the same time helps to explain what happens during free fall. The experiment remains high-tech in the sense that students learn to use updated equipment to record data and to carry out the analysis.

  13. A Modified Edge Crack Torsion Test for Measurement of Mode III Fracture Toughness of Laminated Tape Composites

    NASA Technical Reports Server (NTRS)

    Czabaj, Michael W.; Davidson, Barry D.; Ratcliffe, James G.

    2016-01-01

    Modifications to the edge crack torsion (ECT) test are studied to improve the reliability of this test for measuring the mode-III fracture toughness, G (sub IIIc), of laminated tape fiber-reinforced polymeric (FRP) composites. First, the data reduction methods currently used in the ECT test are evaluated and deficiencies in their accuracy are discussed. An alternative data reduction technique, which uses a polynomial form to represent ECT specimen compliance solution, is evaluated and compared to FEA (finite element analysis) results. Second, seven batches of ECT specimens are tested, each batch containing specimens with a preimplanted midplane edge delamination and midplane plies with orientations of plus theta divided by minus theta, with theta ranging from 0 degrees to 90 degrees in 15-degree increments. Tests on these specimens show that intralaminar cracking occurs in specimens from all batches except for which theta = 15 degrees and 30 degrees. Tests on specimens of these two batches are shown to result in mode-III delamination growth at the intended ply interface. The findings from this study are encouraging steps towards the use of the ECT test as a standardized method for measuring G (sub IIIc), although further modification to the data reduction method is required to make it suitable for use as part of a standardized test method.

  14. An comprehensive time-distance measurement of deep meridional flow and its temporal variation

    NASA Astrophysics Data System (ADS)

    Chen, Ruizhu; Zhao, Junwei

    2016-10-01

    We report our latest results on the Sun's deep solar meridional-flow measurements by time-distance helioseismology technique using 6 years of SDO/HMI Doppler-velocity data. Determination of the meridional flow by time-distance helioseismology depends on a precise measurement of the flow-induced travel-time shifts of acoustic waves traveling in the solar interior. To resolve the weak travel-time-shift signals due to deep meridional flow, we need a high signal-to-noise ratio and a robust removal of the center-to-limb (CtoL) effect, which dominates the travel-time shifts. Here we perform an ultimately comprehensive measurement that tracks acoustic waves between any two points on solar surface. The travel-time shifts are composed of CtoL effect, which is a function of disk-centric distances, and contribution from the flow component parallel to wave traveling direction, which is a function of latitude and orientation. Assuming these two effects are independent, we can derive the CtoL effect and meridional-flow contributions by solving a set of linear equations in a least-square sense. We show the solved CtoL effect and the inversion results for the solar meridional flow, and analyze the annual variation of meridional flow from May 2010 to Apr 2016.

  15. Influence of technology on magnetic tape storage device characteristics

    NASA Technical Reports Server (NTRS)

    Gniewek, John J.; Vogel, Stephen M.

    1994-01-01

    There are available today many data storage devices that serve the diverse application requirements of the consumer, professional entertainment, and computer data processing industries. Storage technologies include semiconductors, several varieties of optical disk, optical tape, magnetic disk, and many varieties of magnetic tape. In some cases, devices are developed with specific characteristics to meet specification requirements. In other cases, an existing storage device is modified and adapted to a different application. For magnetic tape storage devices, examples of the former case are 3480/3490 and QIC device types developed for the high end and low end segments of the data processing industry respectively, VHS, Beta, and 8 mm formats developed for consumer video applications, and D-1, D-2, D-3 formats developed for professional video applications. Examples of modified and adapted devices include 4 mm, 8 mm, 12.7 mm and 19 mm computer data storage devices derived from consumer and professional audio and video applications. With the conversion of the consumer and professional entertainment industries from analog to digital storage and signal processing, there have been increasing references to the 'convergence' of the computer data processing and entertainment industry technologies. There has yet to be seen, however, any evidence of convergence of data storage device types. There are several reasons for this. The diversity of application requirements results in varying degrees of importance for each of the tape storage characteristics.

  16. Laser-assisted patterning of double-sided adhesive tapes for optofluidic chip integration

    NASA Astrophysics Data System (ADS)

    Zamora, Vanessa; Janeczka, Christian; Arndt-Staufenbiel, Norbert; Havlik, George; Queisser, Marco; Schröder, Henning

    2018-02-01

    Portable high-sensitivity biosensors exhibit a growing demand in healthcare, food industry and environmental monitoring sectors. Optical biosensors based on photonic integration platforms are attractive candidates due to their high sensitivity, compactness and multiplexing capabilities. However, they need a low-cost and reliable integration with the microfluidic system. Laser-micropatterned double-sided biocompatible adhesive tapes are promising bonding layers for hybrid integration of an optofluidic biochip. As a part of the EU-PHOCNOSIS project, double-sided adhesive tapes have been proposed to integrate the polymer microfluidic system with the optical integrated waveguide sensor chip. Here the adhesive tape should be patterned in a micrometer scale in order to create an interaction between the sample that flows through the polymer microchannel and the photonic sensing microstructure. Three laser-assisted structuring methods are investigated to transfer microchannel patterns to the adhesive tape. The test structure design consists of a single channel with 400 μm wide, 30 mm length and two circular receivers with 3 mm radius. The best structuring results are found by using the picosecond UV laser where smooth and straight channel cross-sections are obtained. Such patterned tapes are used to bond blank polymer substrates to blank silicon substrates. As a proof of concept, the hybrid integration is tested using colored DI-water. Structuring tests related to the reduction of channel widths are also considered in this work. The use of this technique enables a simple and rapid manufacturing of narrow channels (50-60 μm in width) in adhesive tapes, achieving a cheap and stable integration of the optofluidic biochip.

  17. Adsorption of dispersants on zirconia powder in tape-casting slip compositions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richards, V.L. II

    This paper reports the determination of adsorption isotherms for menhaden fish oil and glycerol trioleate on doped zirconia powder in solvents composed of 70% methyl ethyl ketone (MEK) and 30% ethanol. In order to approach tape-casting zirconia on a sound technical basis, the correspondence of slip viscosities and tape sintered densities to the adsorption isotherms was studied.

  18. Heat reflecting tape for thermoelectric converter

    DOEpatents

    Purdy, David L.

    1977-01-01

    Threads are interlaced with thermoelectric wires to provide a woven cloth in tape form, there being an intermediate layer of heat radiation reflecting material (e.g., aluminum foil) insulated electrically from said wires, which are of opposite thermoelectric polarity and connected as a plurality of thermocouples.

  19. Magnetic and Electrical Characteristics of Permalloy Thin Tape Bobbin Cores

    NASA Technical Reports Server (NTRS)

    Schwarze, Gene E.; Wieserman, William R.; Niedra, Janis M.

    2005-01-01

    The core loss, that is, the power loss, of a soft ferromagnetic material is a function of the flux density, frequency, temperature, excitation type (voltage or current), excitation waveform (sine, square, etc.) and lamination or tape thickness. In previously published papers we have reported on the specific core loss and dynamic B-H loop results for several polycrystalline, nanocrystalline, and amorphous soft magnetic materials. In this previous research we investigated the effect of flux density, frequency, temperature, and excitation waveform for voltage excitation on the specific core loss and dynamic B-H loop. In this paper, we will report on an experimental study to investigate the effect of tape thicknesses of 1, 1/2, 1/4, and 1/8-mil Permalloy type magnetic materials on the specific core loss. The test cores were fabricated by winding the thin tapes on ceramic bobbin cores. The specific core loss tests were conducted at room temperature and over the frequency range of 10 kHz to 750 kHz using sine wave voltage excitation. The results of this experimental investigation will be presented primarily in graphical form to show the effect of tape thickness, frequency, and magnetic flux density on the specific core loss. Also, the experimental results when applied to power transformer design will be briefly discussed.

  20. Fabrication Of Carbon-Boron Reinforced Dry Polymer Matrix Composite Tape

    NASA Technical Reports Server (NTRS)

    Belvin, Harry L.; Cano, Roberto J.; Treasure, Monte; Shahood, Thomas W.

    1999-01-01

    Future generation aerospace vehicles will require specialized hybrid material forms for component structure fabrication. For this reason, high temperature composite prepregs in both dry and wet forms are being developed at NASA Langley Research Center (LaRC). In an attempt to improve compressive properties of carbon fiber reinforced composites, a hybrid carbon-boron tape was developed and used to fabricate composite laminates which were subsequently cut into flexural and compression specimens and tested. The hybrid material, given the designation HYCARB, was fabricated by modifying a previously developed process for the manufacture of dry polymer matrix composite (PMC) tape at LaRC. In this work, boron fibers were processed with IM7/LaRC(TradeMark)IAX poly(amide acid) solution-coated prepreg to form a dry hybrid tape for Automated Tow Placement (ATP). Boron fibers were encapsulated between two (2) layers of reduced volatile, low fiber areal weight poly(amide acid) solution-coated prepreg. The hybrid prepreg was then fully imidized and consolidated into a dry tape suitable for ATP. The fabrication of a hybrid boron material form for tow placement aids in the reduction of the overall manufacturing cost of boron reinforced composites, while realizing the improved compression strengths. Composite specimens were press-molded from the hybrid material and exhibited excellent mechanical properties.