Sample records for tape obturator procedure

  1. Ten-Year Followup after Tension-Free Vaginal Tape-Obturator Procedure for Stress Urinary Incontinence.

    PubMed

    Ulrich, Daniela; Tammaa, Ayman; Hölbfer, Susanne; Trutnovsky, Gerda; Bjelic-Radisic, Vesna; Tamussino, Karl; Aigmüller, Thomas

    2016-10-01

    Suburethral tapes are a standard surgical treatment for stress urinary incontinence. The aim of the study was to evaluate subjective and objective cure rates 10 years after a tension-free vaginal tape-obturator procedure. All 124 patients who underwent the tension-free vaginal tape-obturator procedure at a total of 2 centers in 2004 and 2005 were invited for followup. Objective cure was defined as a negative cough stress test at 300 ml. Subjects completed KHQ (King's Health Questionnaire), IOQ (Incontinence Outcome Questionnaire), FSFI (Female Sexual Function Index Questionnaire) and PGI-I (Patient Global Impression of Improvement). Overall, 55 of 112 women (49%) who were alive were available for clinical examination and 71 (63%) completed the questionnaires. The objective cure rate in the 55 women examined clinically was 69%, 22% were not cured and 9% (5) had undergone reoperation for recurrent or persistent stress urinary incontinence. Treatment was counted as having failed in these 5 women for study purposes. Subjective cure was reported by 45 of 71 women (64%). Three patients (5%) had vaginal tape extrusion at the time of clinical examination. Extrusion in all of them was small and asymptomatic, and did not require treatment for a cumulative extrusion rate of 7%. Six women (9%) had undergone reoperation for tension-free vaginal tape-obturator associated complications and 18 (26%) experienced de novo overactive bladder. Subjective and objective cure rates 10 years after the tension-free vaginal tape-obturator procedure were 69% and 64%, respectively. The vaginal extrusion rate in this study was slightly higher than in other series but major long-term complications appeared to be rare. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  2. TVT and TVT-Obturator: comparison of two operative procedures.

    PubMed

    Neuman, Menahem

    2007-03-01

    To compare two anti-incontinence operations: the tension-free vaginal tape (TVT) and the TVT-Obturator for the first two 75-patient groups. One surgeon operated on two patient groups with urodynamically proven urinary stress incontinence. The first 75-patient group in 1998 included the first TVT procedures performed according to Ulmsten [Ulmsten U, Henriksson L, Johnson P, Varhos G. An ambulatory surgical procedure under local anesthesia for treatment of female urinary incontinence. Int Urogynecol J 1996;7:81-6]. Follow-up lasted for 5-6 years. The second 75-patient group in 2004 included the first TVT-Obturator operations performed according to [De Leval J. Novel surgical technique for the treatment of female stress urinary incontinence: transobturator vaginal tape inside-out. Eur. Urol. 2003;44:724-30]. Follow-up lasted for 6-13 months. The two patient groups were similar from the demographic and therapeutic points of view. The TVT-Obturator procedure required neither bladder catheterization nor intra-operative diagnostic cystoscopy. TVT-related bladder penetration (8.0%), post-operative voiding difficulties (5.0%), intra-operative bleeding (4.0%), post-operative field infection (2.7%), and post-operative pelvic floor relaxation (1.3%) were not noted with the TVT-Obturator. The early therapeutic failure rates were 2.7% for the TVT and 1.3% for the TVT-Obturator, and neither bowel nor urethral injuries were recorded. The surgeons' learning curves of these two minimally invasive surgical procedures for the treatment of female urinary stress incontinence are comparable. The safety and cost-effectiveness of the TVT are well-established. The TVT-Obturator, a novel mid-urethral sling, was designed to overcome some of the TVT-related operative complications. The TVT-Obturator patients seem to have less intra-operative and post-operative surgical complications than the TVT patients. However, long-term comparative data collection is required prior to drawing solid

  3. Modified prepubic TVT-obturator tape procedure versus the conventional method: a preliminary study.

    PubMed

    Long, Cheng-Yu; Wu, Ming-Ping; Wang, Chiu-Lin; Lin, Kun-Ling; Liu, Cheng-Min; Wu, Shu-Hui; Juan, Yung-Shun

    2013-12-01

    To compare the efficacy and safety of the modified prepubic tension-free vaginal tape-obturator (PTVT-O) system procedure with the original TVT-O methods. One hundred and ninety women with urodynamic stress incontinence (USI) were included in this study (93 cases in the TVT-O group and 97 in the PTVT-O group). Clinical assessments before and one year after surgery included urinalyses, 1-h pad tests, urodynamic studies, and a personal interview with the overactive bladder symptom score (OABSS) questionnaire. There were no differences between the two groups in mean age, parity, menopausal status, mean operative time and subjective cure rates (P>0.05), but the efficacy of surgery (cure and improvement) in the PTVT-O group was significantly higher than that in the TVT-O group (P=0.038). Complication rates and visual analog scale (VAS) scores were found to be similar (P>0.05). OABSS decreased significantly after surgery in both groups (P<0.05) although all urodynamic parameters revealed no significant difference after both procedures (P>0.05). Our modified procedure is a safe and effective treatment for female USI. It has an advantage over the original TVT-O with better surgical efficacy and comparable postoperative pain, although the follow-up times in this study are different. Copyright © 2013. Published by Elsevier Ireland Ltd.

  4. Trans-Obturator-Tape (T.O.T.) "outside-in" approach in surgical treatment of female stress urinary incontinence.

    PubMed

    Jovanović, M; Džamić, Z; Aćimović, M; Kajmaković, B; Pejčić, T

    2014-01-01

    The aim of the study was to analyzed the efficacy and safety of a minimally invasive surgical procedure using the Trans- Obturator-Tape with "outside-in" approach for treatment female stress urinary incontinence. 171 women with stress urinary incontinence (SUI) associated with urethral hypermobility, underwent the T.O.T. procedure (March 2010 to January 2014). 27 patients were previously operated for incontinence. Mean age was 59 years (37-80). 6 patients were having mixed incontinence, and 51 had SUI with urgencies. A non-elastic, polypropylene tape was placed under the mid-urethra. The surgical placement technique utilises a trans-obturator percutaneous approach. All patients underwent post-operative clinical examination, cough-stress test (full bladder), uroflowmetry, and post-voiding residual assessment. Mean follow-up was 22 months (4-45). At 12 months follow-up 91,2% of the patients were completely cured. The overall peri-operative complication rate was 6.4% with no vascular, nerve or bowel injury. 5 patients (2.9%) had post-operative urinary retention. The present study confirms the results obtained by the instigator of the technique, E. Delorme, and allows us to consider T.O.T. as an effective and safe technique for the treatment of female stress urinary incontinence.

  5. Usage of a Trans-Obturator-Tape (T.O.T.) "outside-in" approach in surgical treatment of female stress urinary incontinence.

    PubMed

    Jovanovic, Mirko; Vuksanović, Aleksandar; Dzamić', Zoran; Aćimović, Miodrag; Radovanović, Milan; Djurasić, Ljubomir

    2011-01-01

    The aim of the study was to analyzed the efficacy and safety of a new minimally invasive surgical procedure using the Trans-Obturator-Tape with"outside-in" approach for treatment female stress urinary incontinence. 31 women with stress urinary incontinence (SUI) associated with urethral hypermobility, underwent the T.O.T. procedure (March 2010 to January 2011). 5 patients were previously operated for incontinence. Mean age was 59 years (37-80). 10 patients were having mixed incontinence. A non-elastic, polypropylene tape was placed under the mid-urethra. The surgical placement technique utilises a trans-obturator percutaneous approach. All patients underwent post-operative clinical examination, cough-stress test (full bladder), uroflowmetry, and post-voiding residual assessment. Mean follow-up was 5 months (1-9). At 6 months follow-up 96.7% of the patients were completely cured. The overall peri-operative complication rate was 6.4% with no vascular, nerve or bowel injury. One patients (3.4%) had post-operative urinary retention. The present study confirms the results obtained by the instigator of the technique, E. Delorme, and allows us to consider T.O.T. as an effective and safe technique for the treatment of female stress urinary incontinence.

  6. Blood loss in the space of Retzius and pelvis with tension-free vaginal tape and trans-obturator tape procedures.

    PubMed

    Huffaker, R Keith; Copas, Pleas

    2006-11-01

    The purpose of this study was to evaluate the space of Retzius and pelvis for hematoma formation and blood loss following placement of tension-free vaginal tapes (TVT) and transobturator tapes (TOT). 25 women were examined with ultrasonography on post-operative days one, two, three, four or five. One patient underwent TVT while the other 24 underwent TOT. Additional procedures were performed on most patients. No hematomas or collections of free fluid were identified post-operatively. TVT and TOT procedures are relatively safe procedures. We encountered no vascular complications in this small series of patients. Review of literature has yielded reports of infrequent complications.

  7. Surgical treatment of female stress urinary incontinence with a trans-obturator-tape (T.O.T.) Uratape: short term results of a prospective multicentric study.

    PubMed

    Costa, P; Grise, P; Droupy, S; Monneins, F; Assenmacher, C; Ballanger, P; Hermieu, J F; Delmas, V; Boccon-Gibod, L; Ortuno, C

    2004-07-01

    The aim of the study was to assess the efficacy and safety of a new minimally invasive surgical procedure using the Trans-Obturator-Tape Uratape to treat female stress urinary incontinence. 183 women with stress urinary incontinence (SUI) associated with urethral hypermobility, underwent the T.O.T. procedure (October 2001 to March 2003). 26 patients were previously operated for incontinence. 26 patients were operated at the same time for their genital prolapse. Mean age was 56 years (29-87). 50/183 patients were having mixed incontinence. A non-elastic, polypropylene tape (UraTape, Mentor-Porgès) with a silicon coated central part was placed under the mid-urethra. The surgical placement technique utilises a trans-obturator percutaneous approach. All patients underwent post-operative clinical examination, cough-stress test (full bladder), uroflowmetry, and post-voiding residual assessment. Mean follow-up was 7 months (1-21). At 1 year follow-up 80.5% of the patients were completely cured and 7.5% were improved. The overall peri-operative complication rate was 2.2% with no vascular, nerve or bowel injury. 6 patients (3.3%) had post-operative urinary retention. The present multicentric study confirms the results obtained by the instigator of the technique, E. Delorme, and allows us to consider T.O.T. as an effective and safe technique for the treatment of female stress urinary incontinence, alone or in combination with prolapse repair. Copyright 2004 Elsevier B.V.

  8. Chronic vaginal discharge and left leg edema after a transobturator tape procedure.

    PubMed

    Kim, Tae-Hee; Lee, Hae-Hyeog; Kim, Jun-Mo

    2014-05-01

    We report on a patient who underwent total vaginal hysterectomy for urinary incontinence 8 years previously with a sling operation using transobturator tape (TOT). She was admitted to our hospital after complaints of vaginal discharge, foul odor, and bleeding, left thigh pain, and edema. Magnetic resonance imaging (MRI) and computed tomography (CT) revealed a fistula tract from the vagina or urethra with remnant sling tape. We removed the remnant tape using intraoperative ultrasonography. This case exemplifies the rare occurrence of a vaginal fistula extending to the obturator, adductor, and pectineus muscles combined with myositis after TOT placement. It is important that urogynecologists recognize that TOT procedures may result in complications accompanied by common recurrent vaginal symptoms, such as vaginal odor and spotting, which can be identified by MRI or CT.

  9. [A comparative study on treating femal stress urinary incontinence with TVT-Abbrevo and TVT-Obturator].

    PubMed

    Li, W L; Lu, Z W; Li, F P; Yu, H Y

    2016-07-26

    To compare the effectiveness and complications of TVT-Abbrevo (tension-free vaginal tape-Abbrevo) and TVT-Obturator (tension-free vaginal tape-obturator) for the treatment of female stress urinary incontinence (SUI). From Nov.2012 to Nov.2013, 117 patients suffering from SUI were treated with TVT-Abbrebo (n=79) or TVT-Obturator (n=38) procedure, the clinical efficacy and operation-correlated complications were observed. A total of 117 cases, 107 cases of urinary incontinence symptoms disappeared completely, 10 cases were improved. 72 cases (91.1%) were cured and 7 cases (8.9%) were improved in TVT-Abbrevo group; 35 cases (92.1%) were cured and 3 cases (7.9%) were improved in TVT-Obturator group. No significant differences could be found for the curing rates between two groups (P>0.05). Compared with the TVT-Obturator group, the TVT-Abbrevo group had less patients complaining of inner thigh pain at 24 h and 1 w after surgery (P<0.05). No significant differences were observed for the incidence of inner thigh pain at 1m and 1y after surgery between TVT-Abbrevo and TVT-Obturator group (P>0.05). No intraoperative complications such as blood vessel, nerve, bladder damage were recorded and no postoperative retropubic hematoma, tape adjustment and other complications occurred in two goups. No recurrence after 1 year follow-up. The study shows that TVT-Abbrevo procedure is safe and efficacy in treatment of SUI, and associated with low incidence of recent postoperative inner thigh pain.

  10. TVT ABBREVO: cadaveric study of tape position in foramen obturatum and adductor region.

    PubMed

    Hubka, Petr; Nanka, Ondrej; Masata, Jaromir; Martan, Alois; Svabik, Kamil

    2016-07-01

    The aim of the study was to describe fixation of the TVT ABBREVO and establish whether the tape penetrates through obturator muscles and membrane (obturator complex) into the adductor region and, if so, how far it penetrates. Eight formalin-embalmed female cadavers were used to simulate TVT ABBREVO surgery (totalling 16 insertions). Following tape insertion, dissection was performed and ends of the tape were identified. In cases of penetration, the length of tape penetrating into the adductor region was measured. Of the 16 cases, the tape ended in the obturator membrane in eight, in the internal obturator muscle in one, and penetrated through the obturator membrane into the external obturator muscle in five, where it remained. In two cases, it penetrated through the obturator internus muscle, obturator membrane and obturator externus muscle into the group of thigh adductors; one penetration was by 3 mm and the second by 10 mm. No contact with the obturator nerve or its branches was noted in any case. No TVT contact with the obturator nerve was noted; tape penetrated into the adductor region in two of the 16 cases.

  11. Objective and subjective cure rates after trans-obturator tape (OBTAPE) treatment of female urinary incontinence.

    PubMed

    Deval, Bruno; Ferchaux, Jérome; Berry, Richard; Gambino, Sandro; Ciofu, Calin; Rafii, Arash; Haab, François

    2006-02-01

    To evaluate the safety and efficacy of a thermally bonded nonwoven polypropylene mesh in a transobturator suburethral tape procedure (OBTAPE), Mentor-Porges, Le Plessis Robinson, France) for women with stress urinary incontinence. Between January 2003 and January 2005, 129 consecutive women (mean age 57.2 years) underwent OBTAPE) in two academic centers. All the patients had stress urinary incontinence preoperatively. Detrusor instability was ruled out by cystometry. The women were evaluated 1, 6 and 12 months postoperatively. The objective cure rate was evaluated by clinical examination and the subjective cure rate was assessed using the KHQ and BFLUTS questionnaire. Mean follow-up was 17.2+/-4.7 months (range 4 to 28 months). The objective and subjective cure rates were respectively 89.9% and 77.5%. Most of the patients received general anesthesia (85.3%). Urinary retention was observed in two women (1.5%), necessitating tape adjustment. Voiding difficulties were observed in 7 cases (5.4%) necessitating intermittent self-catheterization for 4.2+/-2.4 days (range 1 to 7 days). Seven patients developed vaginal erosion (one with vaginal extrusion, and two with an obturator abscess). Complete mesh removal was necessary in 6 patients, four of whom had recurrent stress urinary incontinence. Our results suggest that the OBTAPE) is an effective treatment for women with stress urinary incontinence. However, vaginal mesh erosion occurred in 6.2% of women, and this implies the need for careful follow-up.

  12. Surgical management of stress urinary incontinence in women: safety, effectiveness and cost-utility of trans-obturator tape (TOT) versus tension-free vaginal tape (TVT) five years after a randomized surgical trial

    PubMed Central

    2011-01-01

    Background We recently completed a randomized clinical trial of two minimally invasive surgical procedures for stress urinary incontinence, the retropubic tension-free vaginal tape (TVT) versus the trans-obturator tape (TOT) procedure. At one year postoperatively, we were concerned to find that a significant number of women had tape that was palpable when a vaginal examination was undertaken. Because the risk factors for adverse outcomes of tape surgery are not clearly understood, we are unable to say whether palpable tapes will lead to vaginal erosions or whether they merge into vaginal tissue. We do not know whether patients go on to have further adverse consequences of surgery, leading to additional cost to patients and healthcare system. Our current study is a 5 year follow-up of the women who took part in our original trial. Methods/Design All 199 women who participated in our original trial will be contacted and invited to take part in the follow-up study. Consenting women will attend a clinic visit where they will have a physical examination to identify vaginal erosion or other serious adverse outcomes of surgery, undertake a standardized pad test for urinary incontinence, and complete several health-related quality of life questionnaires (15D, UDI-6, IIQ-7). Analyses will compare the outcomes for women in the TOT versus TVT groups. The cost-effectiveness of TOT versus TVT over the 5 years after surgery, will be assessed with the use of disease-specific health service administrative data and an objective health outcome measure. A cost-utility analysis may also be undertaken, based on economic modeling, data from the clinical trial and inputs obtained from published literature. Discussion This study is needed now, because TOT and TVT are among the most frequently conducted surgical procedures for stress urinary incontinence in Canada. Because stress urinary incontinence is so common, the impact of selecting an approach that causes more adverse events, or is

  13. Trans-obturator vaginal tape (TOT) for female stress incontinence: one year follow-up in 120 patients.

    PubMed

    Roumeguère, Thierry; Quackels, Th; Bollens, R; de Groote, A; Zlotta, A; Bossche, M Vanden; Schulman, C

    2005-11-01

    The aim of this study was to evaluate the effectiveness of a new minimally invasive surgical procedure, the Trans-obturator Vaginal Tape (TOT) in the treatment of female urodynamic stress incontinence (USI) and to analyse functional results and quality of life after one year of follow up. 120 consecutive women with stress urinary incontinence underwent the procedure since February 2002 under general or loco-regional anesthesia. Minimum follow up was one year (range 12-30 months). Mean age was 58 years (range 31-86). 70% of the patients had pure USI. 5 patients were previously operated for USI. In 10 cases, concomitant repair of pelvic floor defects was mandatory. Collection of the data included operative time, pre- and post-operative complications. Patients were post-operatively assessed at one week, one month and one year. A validated urinary incontinence-specific measure of Quality of Life (QoL) questionnaire (Contilife) was sent and completed 12 months after surgery. The mean operative time was 12 min (range 6-30) with a catheterisation time of 0,9 day (range 0-2). No severe bleeding was observed. There were 13 minor lateral tears of the vagina without any sequelae. Three perforations of the urethra and one of the bladder occurred during the learning phase. In two cases a re-intervention was necessary for tape removal when the injury was not recognised during the procedure. Two transient urinary retention needed a supra pubic catheter and tape release. Eleven women presented transient voiding outflow obstruction. After one month, 93% patients were cured with no pad and a negative cough test with a full bladder. Uroflowmetry did not show any significant changes between pre- and post-operative time in all the population. De novo urgency occurred only in 2.5% and persistent dysuria (Qmax <10 ml/s and/or post-void residual volume >120 cc) in 4%. 80% of patients were completely dry after one year and 12% were greatly improved. According to the pre-operative maximal

  14. Clinical and ultrasonographic correlations following three surgical anti-incontinence procedures (TOT, TVT and TVT-O).

    PubMed

    Chene, Gautier; Cotte, Benjamin; Tardieu, Anne-Sylvie; Savary, Denis; Mansoor, Aslam

    2008-08-01

    The aim of this study was to compare ultrasonographic findings on tape position, angulation and mobility following three surgical anti-incontinence procedures (trans-obturator tape (TOT), tension-free vaginal tape (TVT), tension-free vaginal tape obturator (TVT-O)) and to correlate these data with clinical signs of cures and failures and de novo voiding disorders. In this prospective study, vesicourethral static and dynamic analysis of 81 patients (30 TOT, 28 TVT, 23 TVT-O) were evaluated using introital ultrasonography. Width, position and appearance of the tape were similar in all three groups, i.e. like a "V" at rest, round angulation on Valsalva and closed angulation at maximum retaining. Moreover, closer angulation on Valsalva was associated with voiding disorders. Closer angulation at retaining was associated with de novo urge incontinence. Larger angulation of the tape at rest appeared to be significantly associated with recurrent stress incontinence. Ultrasonography could a be useful tool assessing anti-incontinence procedures and investigating post-operative voiding disorders.

  15. Randomized clinical trial comparing TVT Secur system and trans vaginal obturator tape for the surgical management of stress urinary incontinence.

    PubMed

    Maslow, Ken; Gupta, Chander; Klippenstein, Peter; Girouard, Lise

    2014-07-01

    This prospective randomized study aimed to compare the safety and efficacy of the TVT-Secur (TVT-S) with the trans vaginal obturator tape (TVT-O) for the treatment of stress urinary incontinence. We set out to enroll 136 patients in our study. 106 patients with stress urinary incontinence were randomized to either the TVT-S (n = 56) or TVT-O (n = 50) procedure. Patients were evaluated postoperatively at 2 months and 1 year. Our primary outcome was objective cure measured by the cough test. Secondary outcomes of subjective symptoms, questionnaires, pain scores, complications, and urodynamic studies were also included. Statistical analysis was by Chi-squared, Kruskal-Wallis, Wilcoxon, and Fisher's exact tests as appropriate. P values of <0.05 were considered significant. Objective cure rates were better for TVT-O compared with TVT-S at 1 year (86 % and 63 % respectively, p = 0.01). Subjective cure rates were 88 % for TVT-O and 63 % for TVT-S. Quality of life scores through questionnaires improved in both groups and were not statistically different. Initial post-operative groin pain was more prevalent in the TVT-O group; however, this resolved quickly with time. TVT-O was superior to TVT-S in the objective cure of stress urinary incontinence at 1-year follow-up.

  16. One-year follow-up of tension-free vaginal tape (TVT) and trans-obturator suburethral tape from inside to outside (TVT-O) for surgical treatment of female stress urinary incontinence: a prospective randomised trial.

    PubMed

    Zullo, Marzio Angelo; Plotti, Francesco; Calcagno, Marco; Marullo, Elettra; Palaia, Innocenza; Bellati, Filippo; Basile, Stefano; Muzii, Ludovico; Angioli, Roberto; Panici, Pierluigi Benedetti

    2007-05-01

    To compare tension-free vaginal tape (TVT) and trans-obturator suburethral tape from inside to outside (TVT-O) for surgical treatment of stress urinary incontinence (SUI) for complications (primary end point) and success rate (secondary end point). Seventy-two consecutive patients, with a mean age of 53.2 yr (range: 38-69 yr) and affected by SUI, were included in this randomised controlled trial. After preoperative assessment, patients were randomly allocated to the TVT or TVT-O procedure. Operative time, perioperative complications, and hospital stay were prospectively recorded. Cure of SUI was defined as no leakage of urine during the stress test at urodynamic testing at the 12-mo evaluation. The Wilcoxon signed rank sum test, Mann-Whitney U test, McNemar test, and Fisher exact test were used to verify statistical significance, set at p<0.05. All patients were evaluable at the 12-mo follow-up. The characteristics of patients were well balanced between groups after randomisation. The mean operative time was significantly shorter in the TVT-O group. Perioperative complications were significantly more common after the retropubic approach (5% and 27% in TVT-O and TVT groups, respectively, p<0.04). The groups did not differ significantly in intraoperative blood loss, hospital stays, and time to return to normal activities. Sixty-five patients (90%) were successfully treated for SUI 12 mo after the operation (89% and 91% for TVT-O and TVT groups, respectively). Both techniques appear to be equally effective in the surgical treatment of SUI. However, TVT-O had a shorter operative time and lower overall perioperative complication rate.

  17. New surgical technique for treatment of stress urinary incontinence TVT-ABBREVO from development to clinical experience.

    PubMed

    Waltregny, David; de Leval, Jean

    2012-12-01

    Tension-free suburethral tapes have revolutionized the surgical treatment of female stress urinary incontinence (SUI). These tapes are inserted by way of a retropubic or transobturator route. The inside-out tension-free vaginal tape transobturator approach, or TVT-Obturator system (TVT-O, Ethicon Women's Health and Urology, Somerville, NJ), was developed ten years ago with the aim of minimizing the risk of urinary tract injuries associated with retropubic and outside-in transobturator tapes while reproducibly ensuring minimal tissue dissection. Cadaveric studies have shown that the anatomical trajectory of the TVT-O tape is strictly perineal and courses away from neighboring obturator and pudendal neurovascular structures. Several meta-analyses have shown similar SUI cure rates after retropubic and transobturator tape procedures. Yet, the transobturator route may be associated with less voiding dysfunction, blood loss, bladder perforation, and shorter operating time. The original TVT-O procedure was modified with the aim of reducing the incidence of postoperative groin pain as well as the rather theoretical risk of obturator nerve injury. This modified procedure, named TVT-ABBREVO (Ethicon Women's Health and Urology, Somerville, NJ), utilizes a shortened, 12-cm-long polypropylene tape. In addition, perforation of the obturator membrane with the scissors and guide is avoided in order to reduce the depth of lateral dissection, and consequently, to maximize securing of the tape within the obturator muscular/aponeurotic structures. In a comparative anatomical study, it was indeed observed that the shorter tape traversed less muscular structures (with no or only a minimal amount of tape lying in the adductor muscles) than its original counterpart, while still consistently anchoring in the obturator membrane at a similarly safe distance from the obturator canal. In a single-center randomized clinical trial, after a 3-year minimum follow-up, the modified TVT-O procedure

  18. Effect of tension-free vaginal tape and TVT-obturator on lower urinary tract symptoms other than stress urinary incontinence.

    PubMed

    Ballert, Katie N; Kanofsky, Jamie A; Nitti, Victor W

    2008-03-01

    Variable effects on lower urinary tract symptoms (LUTS) other than stress urinary incontinence (SUI) have been reported after tension-free vaginal tape (TVT). We measured the effect of TVT on LUTS using the American Urological Association Symptom Index (AUASI). Patients undergoing TVT completed the AUASI pre- and post-operatively. Total scores (TS), storage scores (SS), and voiding scores (VS) were compared overall and among patients with SUI vs mixed urinary incontinence (MUI) and those who underwent TVT vs TVT-obturator (TVT-O). The mean change in TS and SS was -3.6 and -3.0. Mean reductions in TS and SS were significant in all patient subsets with no change in VS. There was no significant difference in the mean changes in TS between patients with SUI vs MUI or those undergoing TVT vs TVT-O. LUTS are improved after TVT in most patients. In general, voiding symptoms were not adversely affected.

  19. SPEECH EVALUATION WITH AND WITHOUT PALATAL OBTURATOR IN PATIENTS SUBMITTED TO MAXILLECTOMY

    PubMed Central

    de Carvalho-Teles, Viviane; Pegoraro-Krook, Maria Inês; Lauris, José Roberto Pereira

    2006-01-01

    Most patients who have undergone resection of the maxillae due to benign or malignant tumors in the palatomaxillary region present with speech and swallowing disorders. Coupling of the oral and nasal cavities increases nasal resonance, resulting in hypernasality and unintelligible speech. Prosthodontic rehabilitation of maxillary resections with effective separation of the oral and nasal cavities can improve speech and esthetics, and assist the psychosocial adjustment of the patient as well. The objective of this study was to evaluate the efficacy of the palatal obturator prosthesis on speech intelligibility and resonance of 23 patients with age ranging from 18 to 83 years (Mean = 49.5 years), who had undergone inframedial-structural maxillectomy. The patients were requested to count from 1 to 20, to repeat 21 words and to spontaneously speak for 15 seconds, once with and again without the prosthesis, for tape recording purposes. The resonance and speech intelligibility were judged by 5 speech language pathologists from the tape recordings samples. The results have shown that the majority of patients (82.6%) significantly improved their speech intelligibility, and 16 patients (69.9%) exhibited a significant hypernasality reduction with the obturator in place. The results of this study indicated that maxillary obturator prosthesis was efficient to improve the speech intelligibility and resonance in patients who had undergone maxillectomy. PMID:19089242

  20. Anatomy of the obturator region: relations to a trans-obturator sling.

    PubMed

    Whiteside, James L; Walters, Mark D

    2004-01-01

    Our objective was to determine the relationships between a trans-obturator sling and anatomic structures within the obturator region. The obturator regions of six cadavers were dissected and distances from the mid-point of the ischiopubic ramus to the muscles, nerves, and vessels of the region were measured. A trans-obturator sling was placed and distances from the device to the same anatomic structures were determined. Four additional cadavers were dissected to determine the device route of passage. The obturator canal is on average 4.4 cm from the midpoint of the ischiopubic rami. The trans-obturator sling passes on average 2.4 cm inferior-medial to the obturator canal. The anterior and posterior divisions of the obturator nerve are on average 3.4 and 2.8 cm, respectively, from a passed trans-obturator device. The device passed on average 1.1 cm from the most medial branch of the obturator vessels. Vascular and nerve structures are within 1-3 cm of the path of any device passed through the obturator foramen. A trans-obturator sling risks injury to these structures, although the small caliber of the vessels and the confined space in which they would bleed make the consequences of injury uncertain.

  1. Function of obturator prosthesis after maxillectomy and prosthetic obturator rehabilitation.

    PubMed

    Chen, Cheng; Ren, Wenhao; Gao, Ling; Cheng, Zheng; Zhang, Linmei; Li, Shaoming; Zhi, Pro Ke-qian

    2016-01-01

    Maxillary defects are usually rehabilitated by a prosthetic obturator. This study aimed to evaluate the functioning of obturators prosthesis in patients with unilateral defects after maxillectomy. Of 49 patients, 28 underwent to maxillectomy as a result of tumor ablative surgery, and acquired unilateral maxillary defects. Evaluation of the function was performed by applying the Obturator Functional Scale (OFS). From a total of 49 patients, 28 were treated as follows: 9 with a conventional retained obturator prosthesis (COP), 11 (39%) with an enhanced retentive obturator prosthesis with stud attachment (POP) and 8 (28%) with an enhanced retentive obturator prosthesis with magnetic attachment (POM). The mean OFS score was 80. Scores on functions of speech, swallowing and chewing reached statistical significances (p<0.05) among these three subgroups. Comparing COP and MOP groups, the scores of OFS in the domains of "Speech-ability to speak in public" and "Swallowing-leakage with liquids" were significantly higher in AOP group. Comparing COP group, the scores of OFS in "Swallowing-leakage with solid" and "Chewing/eating" domains were increased significantly (p<0.05) both in MOP and AOP groups. Obturator prosthesis improves oral function of patients after maxillary defects; the retention of the obturator prosthesis enhanced by the addition of attachments showed more benefits in oral function. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  2. The effect of obturator bulb height on speech in maxillectomy patients.

    PubMed

    Kwon, H B; Chang, S W; Lee, S H

    2011-03-01

    The purpose of this study was to compare the speech function of low height bulb obturators with that of high height bulb obturators. Thirteen maxillectomy patients, who underwent post-operative prosthodontic rehabilitations, were included. Two obturators of the same design except for different bulb heights were fabricated for each maxillectomy patient. One of the two obturators had high bulb design and the other had low bulb design. After one of the obturators was used for a period of 3 weeks, the patient's speaking functions were evaluated by measuring nasalance scores, formant frequencies, and vowel working space areas. The same procedures were repeated with the second obturator following another 3-week period of usage. In addition, the effect of delivery sequence and anatomic conditions related to maxillectomy were analysed. The results demonstrated that the nasalance scores with the low bulb obturators were significantly higher than those with the high bulb obturators. There were no significant differences in formant frequencies based on the bulb height of the obturators. The vowel working spaces for the two obturators were similar in shape and there were no significant differences between the vowel working space areas created by the two obturators. The delivery sequence affected the results. However, there were no significant differences related to the other anatomical variables. Although low bulb obturators might function similarly with high bulb obturators in terms of the articulation of speech, they would exhibit a difficulty in controlling hypernasality in maxillectomy patients. © 2010 Blackwell Publishing Ltd.

  3. Comparison of the efficacy of tension-free vaginal tape obturator (TVT-O) and single-incision tension-free vaginal tape (Ajust™) in the treatment of female stress urinary incontinence: a 1-year follow-up randomized trial.

    PubMed

    Masata, Jaromir; Svabik, Kamil; Zvara, Karel; Hubka, Petr; Toman, Ales; Martan, Alois

    2016-10-01

    The aim of this study was to compare the efficacy of the tension-free vaginal tape obturator (TVT-O) and single-incision tension-free vaginal tape (Ajust™) in the treatment of stress urinary incontinence in a randomized two-arm study with a 1-year follow-up. This single-centre randomized trial compared the objective and subjective cure rates of TVT-O and Ajust using objective criteria (cough test) and subjective criteria (International Consultation on Incontinence Questionnaire short form, ICIQ-UI SF). The objective cure rate was defined as the number of patients with a negative cough stress test. Subjective cure was defined as no stress leakage of urine after surgery based on the ICIQ-UI SF. The primary outcome was to establish differences in objective and subjective cure rates between the TVT-O and Ajust groups. We also compared postoperative pain profiles using a visual analogue scale (VAS), improvement in quality of life using the ICIQ- UI SF and the Incontinence Quality of Life questionnaire, and overall satisfaction with the surgical procedure using a VAS and a five-item Likert scale. Inclusion criteria were age over 18 years, signed informed consent, and urodynamic stress urinary incontinence. Following a power calculation, 50 patients were enrolled into each group (Ajust and TVT-O). The mean follow-up after surgery was 445 days (SD 157.6 days) in the TVT-O group and 451.8 days (SD 127.6 days) in the Ajust group (p = 76.6 %). At 1 year, 47 patients were evaluated in the TVT-O group and 49 in the Ajust group. No differences in subjective cure rates or objective cure rates were observed. In the Ajust and TVT-O groups, the rates for no subjective stress leakage were 89.8 % and 91.5 %, respectively (p = 1.0, OR 1.22, 95 % CI 0.24 - 6.58), and the rates for a negative stress test were 89.8 % and 87.2 %, respectively (p = 0.76, OR 0.77, 95 % CI 0.17 - 3.32). In the Ajust group two patients reported de novo pain during sexual

  4. Measuring cross sections using a sag tape: a generalized procedure

    Treesearch

    Gary A. Ray; Walter F. Megahan

    1979-01-01

    A procedure was developed for surveying cross sections using a sag tape with unequal end elevations. The procedure is as accurate as traditional engineer's level surveys, is faster and easier, and can be programed for a digital computer by following the flow diagram which is provided.

  5. A hollow definitive obturator fabrication technique for management of partial maxillectomy.

    PubMed

    Patil, Pravinkumar Gajanan; Patil, Smita Pravinkumar

    2012-11-01

    Maxillary obturator prosthesis is the most frequent treatment option for management of partial or total maxillectomy. Heavy weight of the obturators is often a dislocating factor. Hollowing the prosthesis to reduce its weight is the well established fact. The alternate technique to hollow-out the prosthesis has been described in this article which is a variation of previously described processing techniques. A pre-shaped wax-bolus was incorporated inside the flasks during packing of the heat-polymerized acrylic resin to automatically create the hollow space. The processing technique described is a single step flasking procedure to construct a closed-hollow-obturator prosthesis as a single unit. To best understand the technique, this article describes management of a patient who had undergone partial maxillectomy secondary to squamous cell carcinoma rehabilitated with a hollow-obturator prosthesis.

  6. Bleeding complication with the TVT-Exact procedure: a report of two cases.

    PubMed

    Masata, Jaromir; Svabik, Kamil; Martan, Alois

    2015-02-01

    Midurethral tension-free vaginal tapes (TVT), placed through the retropubic space or through the obturator foramina, are widely used for the surgical treatment of female stress urinary incontinence. Some complications are associated with retropubic tapes owing to the passage of the tape through the space of Retzius. One of the most frequent complications is bleeding, and if injury to major vessels is involved, this may be life-threatening. In 2010, the Gynecare TVT-Exact® Continence System was introduced onto the market, with a rigid trocar shaft measuring 3.0 mm in diameter. We have no clinical data regarding the complication rate, especially concerning bleeding, connected with this device; all data are related to the original size of the TVT inserter. The cases presented demonstrate that bleeding complications can occur with the TVT-Exact procedure.

  7. A hollow definitive obturator fabrication technique for management of partial maxillectomy

    PubMed Central

    Patil, Smita Pravinkumar

    2012-01-01

    Maxillary obturator prosthesis is the most frequent treatment option for management of partial or total maxillectomy. Heavy weight of the obturators is often a dislocating factor. Hollowing the prosthesis to reduce its weight is the well established fact. The alternate technique to hollow-out the prosthesis has been described in this article which is a variation of previously described processing techniques. A pre-shaped wax-bolus was incorporated inside the flasks during packing of the heat-polymerized acrylic resin to automatically create the hollow space. The processing technique described is a single step flasking procedure to construct a closed-hollow-obturator prosthesis as a single unit. To best understand the technique, this article describes management of a patient who had undergone partial maxillectomy secondary to squamous cell carcinoma rehabilitated with a hollow-obturator prosthesis. PMID:23236579

  8. [Cases of strangulated obturator hernia].

    PubMed

    Chakhvadze, B; Nakashidze, D; Kashibadze, K; Beridze, A

    2010-02-01

    Obturator hernias are extremely rare in surgical practice. Only about 600 cases are described in the world medical literature. To diagnose obturator hernia is very complicated. Hernial protrusion is not often observed. The strangulation of obturator hernia is accompanied by rapidly developing symptoms of intestinal obstruction, which is usually an indication for emergency surgery. The article analyzes two clinical cases of strangulated obturator hernia and one traumatic eventration and strangulation of small intestine in the obturator ring ruined by trauma. In all cases the indication of surgery was clinical picture of a growing intestinal obstruction or acute abdomen. Only in one case, despite the prevailing clinical picture of acute intestinal obstruction in the light of anamnesis and the accompanying neurological symptoms before the operation could be suspected strangulated obturator hernia, which was confirmed during surgery. As it was mentioned above, in doubtful cases to clarify the diagnosis should be applied other methods of examination of patients, including computed tomography.

  9. Comparative evaluation of fracture resistance of root canals obturated with four different obturating systems.

    PubMed

    Punjabi, Mansi; Dewan, Ruchika Gupta; Kochhar, Rohit

    2017-01-01

    The aim of this study is to evaluate and compare the fracture resistance of root canals obturated with four different obturating systems in endodontically treated teeth. One hundred and twenty single-rooted teeth were selected and decoronated at cementoenamel junction. Instrumentation of teeth (except control group) was done with Mtwo rotary files up to size 25/0.06 using a step-back technique. All teeth were divided into four experimental groups ( n = 25) and two control groups ( n = 10). In Group I (negative control), teeth were neither instrumented nor obturated, in Group II (positive control), instrumentation was done, but no obturation was performed, in Group III, obturation was done with cold lateral compaction technique, in Group IV, obturation was done with cold free-flow compaction technique, in Group V, obturation was done with warm vertical compaction technique, and in Group VI, obturation was done with injection-molded thermoplasticized technique. All prepared teeth were embedded in an acrylic resin block, and their fracture strength was measured using Universal Testing Machine. Statistical data were analyzed using one-way analysis of variance and Tukey's honestly significant difference test. Negative control Group I showed highest fracture resistance and positive control Group II had lowest fracture resistance. Among experimental groups, cold free-flow compaction technique with GuttaFlow2 (Group IV) showed higher fracture resistance as compared to the Group III, Group V, and Group VI. GuttaFlow2 has the potential to strengthen the endodontically treated roots to a level that is similar to that of intact teeth.

  10. Comparison of Effectiveness between Tension-Free Vaginal Tape (TVT) and Trans-Obturator Tape (TOT) in Patients with Stress Urinary Incontinence and Intrinsic Sphincter Deficiency.

    PubMed

    Kim, Hyeong Gon; Park, Hyoung Keun; Paick, Sung Hyun; Choi, Woo Suk

    2016-01-01

    The aim of this study was to compare the two types of mid-urethral slings for stress urinary incontinence (SUI) with intrinsic sphincter deficiency (ISD). This retrospective study included patients who underwent tension-free vaginal tape (TVT) procedure or transobturator tape (TOT) procedure by a single surgeon for SUI with ISD, defined as Valsalva leak point pressure (VLPP) < 60 cmH2O in a urodynamic study. Cases of neurogenic bladder, previous SUI surgery, and concomitant cystocele repair were excluded. The primary outcome was treatment success at 12 months, defined by self-reported absence of symptoms, no leakage episodes recorded, and no retreatment. Among the 157 women who were included in the final analysis, 105 patients received TVT and 52 patients received TOT. Age, underlying diseases, Stamey grade, cystocele grade, and presence of urge incontinence were not significantly different between the two groups. Urodynamic parameters including maximal urethral closing pressure, detrusor overactivity, VLPP, urethral hypermobility (Q-tip ≥ 30°), were also comparable between the two groups. Success rate was significantly higher in the TVT group than in the TOT group (95.2% vs. 82.7%, p = 0.009). On multivariate analysis, only TOT surgery (OR = 3.922, 95%CI = 1.223-12.582, p = 0.022) was a risk factor for failure following surgical treatment. TVT is more effective than TOT in treatment of female SUI with ISD.

  11. Comparative evaluation of fracture resistance of root canals obturated with four different obturating systems

    PubMed Central

    Punjabi, Mansi; Dewan, Ruchika Gupta; Kochhar, Rohit

    2017-01-01

    Aim and Objectives: The aim of this study is to evaluate and compare the fracture resistance of root canals obturated with four different obturating systems in endodontically treated teeth. Materials and Methods: One hundred and twenty single-rooted teeth were selected and decoronated at cementoenamel junction. Instrumentation of teeth (except control group) was done with Mtwo rotary files up to size 25/0.06 using a step-back technique. All teeth were divided into four experimental groups (n = 25) and two control groups (n = 10). In Group I (negative control), teeth were neither instrumented nor obturated, in Group II (positive control), instrumentation was done, but no obturation was performed, in Group III, obturation was done with cold lateral compaction technique, in Group IV, obturation was done with cold free-flow compaction technique, in Group V, obturation was done with warm vertical compaction technique, and in Group VI, obturation was done with injection-molded thermoplasticized technique. All prepared teeth were embedded in an acrylic resin block, and their fracture strength was measured using Universal Testing Machine. Statistical data were analyzed using one-way analysis of variance and Tukey's honestly significant difference test. Results: Negative control Group I showed highest fracture resistance and positive control Group II had lowest fracture resistance. Among experimental groups, cold free-flow compaction technique with GuttaFlow2 (Group IV) showed higher fracture resistance as compared to the Group III, Group V, and Group VI. Conclusion: GuttaFlow2 has the potential to strengthen the endodontically treated roots to a level that is similar to that of intact teeth. PMID:29430099

  12. Comparison of Effectiveness between Tension-Free Vaginal Tape (TVT) and Trans-Obturator Tape (TOT) in Patients with Stress Urinary Incontinence and Intrinsic Sphincter Deficiency

    PubMed Central

    Kim, Hyeong Gon; Park, Hyoung Keun; Paick, Sung Hyun; Choi, Woo Suk

    2016-01-01

    Background The aim of this study was to compare the two types of mid-urethral slings for stress urinary incontinence (SUI) with intrinsic sphincter deficiency (ISD). Methods This retrospective study included patients who underwent tension-free vaginal tape (TVT) procedure or transobturator tape (TOT) procedure by a single surgeon for SUI with ISD, defined as Valsalva leak point pressure (VLPP) < 60 cmH2O in a urodynamic study. Cases of neurogenic bladder, previous SUI surgery, and concomitant cystocele repair were excluded. The primary outcome was treatment success at 12 months, defined by self-reported absence of symptoms, no leakage episodes recorded, and no retreatment. Results Among the 157 women who were included in the final analysis, 105 patients received TVT and 52 patients received TOT. Age, underlying diseases, Stamey grade, cystocele grade, and presence of urge incontinence were not significantly different between the two groups. Urodynamic parameters including maximal urethral closing pressure, detrusor overactivity, VLPP, urethral hypermobility (Q-tip ≥ 30°), were also comparable between the two groups. Success rate was significantly higher in the TVT group than in the TOT group (95.2% vs. 82.7%, p = 0.009). On multivariate analysis, only TOT surgery (OR = 3.922, 95%CI = 1.223–12.582, p = 0.022) was a risk factor for failure following surgical treatment. Conclusion TVT is more effective than TOT in treatment of female SUI with ISD. PMID:27228092

  13. Surgical removal of a large vaginal calculus formed after a tension-free vaginal tape procedure.

    PubMed

    Zilberlicht, Ariel; Feiner, Benjamin; Haya, Nir; Auslender, Ron; Abramov, Yoram

    2016-11-01

    Vaginal calculus is a rare disorder which has been reported in association with urethral diverticulum, urogenital sinus anomaly, bladder exstrophy and the tension-free vaginal tape (TVT) procedure. We report a 42-year-old woman who presented with persistent, intractable urinary tract infection (UTI) following a TVT procedure. Cystoscopy demonstrated an eroded tape with the formation of a bladder calculus, and the patient underwent laser cystolithotripsy and cystoscopic resection of the tape. Following this procedure, her UTI completely resolved and she remained asymptomatic for several years. Seven years later she presented with a solid vaginal mass. Pelvic examination followed by transvaginal ultrasonography and magnetic resonance imaging demonstrated a large vaginal calculus located at the lower third of the anterior vaginal wall adjacent to the bladder neck. This video presents the transvaginal excision and removal of the vaginal calculus.

  14. Obturator hernia: A diagnostic challenge.

    PubMed

    Kulkarni, Sanjeev R; Punamiya, Aditya R; Naniwadekar, Ramchandra G; Janugade, Hemant B; Chotai, Tejas D; Vimal Singh, T; Natchair, Arafath

    2013-01-01

    Obturator hernia is an extremely rare type of hernia with relatively high mortality and morbidity. Its early diagnosis is challenging since the signs and symptoms are non specific. Here in we present a case of 70 years old women who presented with complaints of intermittent colicky abdominal pain and vomiting. Plain radiograph of abdomen showed acute dilatation of stomach. Ultrasonography showed small bowel obstruction at the mid ileal level with evidence of coiled loops of ileum in pelvis. On exploration, Right Obstructed Obturator hernia was found. The obstructed Intestine was reduced and resected and the obturator foramen was closed with simple sutures. Postoperative period was uneventful. Obturator hernia is a rare pelvic hernia and poses a diagnostic challenge. Obturator hernia occurs when there is protrusion of intra-abdominal contents through the obturator foramen in the pelvis. The signs and symptoms are non specific and generally the diagnosis is made during exploration for the intestinal obstruction, one of the four cardinal features. Others are pain on the medial aspect of thigh called as Howship Rombergs sign, repeated attacks of Intestinal Obstruction and palpable mass on the medial aspect of thigh. Obturator hernia is a rare but significant cause of intestinal obstruction especially in emaciated elderly woman and a diagnostic challenge for the Doctors. CT scan is valuable to establish preoperative diagnosis. Surgery either open or laproscopic, is the only treatment. The need for the awareness is stressed and CT scan can be helpful. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  15. Predictors of obturator functioning and satisfaction in Turkish patients using an obturator prosthesis after maxillectomy.

    PubMed

    Ozdemir-Karatas, Meltem; Balik, Ali; Evlioglu, Gülümser; Uysal, Ömer; Peker, Kadriye

    2018-03-01

    The aim of this study was to determine the sociodemographic, behavioral, and clinical factors affecting obturator function and satisfaction using the obturator functioning scale (OFS) in maxillectomy patients rehabilitated with obturator prostheses. The study sample consisted of 41 maxillectomy patients. The OFS was translated into Turkish and adapted for assessing obturator functioning and patient satisfaction among Turkish patients. Data were collected from patients' medical records and self-completed questionnaires, including the Turkish version of the OFS, sociodemographic and behavioral characteristics. Descriptive statistics, Mann-Whitney U test, Spearman's correlation coefficient, and backward stepwise multiple linear regression were used for data analysis. Internal consistency (Cronbach's alpha = 0.85) and test-retest reliability (intraclass correlation coefficient = 0.86) were acceptable for the OFS. The most frequently reported problem was "difficulty chewing." Bivariate analysis revealed significant differences in total OFS scores in terms of surgery type, defect size, and education level, except for the other clinical and sociodemographic characteristics and behavioral factors. Education level and surgery type were found to be the most important predictors of patient satisfaction and functioning of the obturator. The Turkish version of the OFS might be a useful tool for clinicians to identify patients who are at risk for poor functioning of the obturator, lack of satisfaction, and unmet needs. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Echocardiographic demonstration of intracardiac glue after endoscopic obturation of gastroesophageal varices.

    PubMed

    Gallet, B; Zemour, G; Saudemont, J P; Renard, P; Hillion, M L; Hiltgen, M

    1995-01-01

    Systemic embolism is an unusual complication of endoscopic obturation of gastroesophageal varices with glue. This report describes a case of cerebral embolism after this procedure. Intracardiac glue within the left atrium was demonstrated by echocardiography. Cardiac fluoroscopy demonstrated an abnormal vessel connecting periesophageal veins with the right upper pulmonary vein. Cardiac surgery was performed. Intracardiac glue was removed and the entering orifice of the abnormal vessel in the right upper pulmonary vein was sutured. To our knowledge, this is the first reported case of intracardiac glue after variceal obturation. Echocardiography is useful in the diagnosis of this rare complication.

  17. Management of vaginal extrusion after tension-free vaginal tape procedure for urodynamic stress incontinence.

    PubMed

    Giri, Subhasis K; Sil, Debasri; Narasimhulu, Girish; Flood, Hugh D; Skehan, Mark; Drumm, John

    2007-06-01

    To report our experience in the management of vaginal extrusion after the tension-free vaginal tape (TVT) procedure for urodynamic stress incontinence. Five patients diagnosed with vaginal extrusion after a TVT procedure performed at our institution were identified. We reviewed the patients' records retrospectively. The interval from TVT placement to diagnosis, presenting symptoms and signs, duration of symptoms, diagnostic test findings, treatment, and postoperative results were recorded. Patients were followed up for at least 12 months. From January 2001 to June 2004, a total of 166 patients underwent the TVT procedure. Of these, 5 patients (3%) were diagnosed with isolated vaginal extrusion 4 to 40 months postoperatively. No cases of urethral or bladder erosion occurred in this series. The symptoms included vaginal discharge, pain, bleeding, and dyspareunia. The eroded margin of the vaginal mucosa was trimmed, mobilized, and closed over the tape with interrupted vertical mattress sutures in a single layer using 2-0 polyglactin 910 to avoid mucosal inversion. All patients remained symptom free without any evidence of defective healing or additional extrusion at a minimal follow-up of 12 months. Primary reclosure of the vaginal mucosa over the TVT tape is an effective first-line treatment option for vaginal extrusion without compromising continence. Patients undergoing the TVT procedure should be adequately counseled about the possibility of this complication and the available treatment options.

  18. Uroflowmetric changes, success rate and complications following Tension-free Vaginal Tape Obturator (TVT-O) operation in obese females.

    PubMed

    Fouad, Reham; El-Faissal, Yahia M; Hashem, Ahmed T; Gad Allah, Sherine H

    2017-07-01

    The goal of this study was to evaluate the outcome of Tension-free Vaginal Tape Obturator (TVT-O) operation in the treatment of urodynamic stress incontinence (USI) in obese females, with respect to uroflowmetric changes, success rate and postoperative complications. This prospective observational study included 26 patients with USI at the Obstetrics & Gynecology department-Cairo University hospital during the year 2015. The participants had body mass index (BMI)≥30. Patients underwent TVT-O operation. Follow up of the patients was performed by cough test and uroflowmetry after one week, one month, three months and six months. Postoperative complications such as groin pain, sense of incomplete emptying, need to strain to complete micturition and urinary tract infection were recorded. Comparisons between groups were done using Chi square, Phi-Cramer test for categorical variables. The mean age for the subjects was 43.58±9.01years. The mean BMI was 33.4±2.1. The success rate of TVT-O operation was 21 out of 26 patients (≈81%). Normal maximum flow rate was in 88% of patients at week one and was normal in 100% of patients at months three and six (p=0.101 & 0.101). Postoperative groin pain was the main complaint during the first week after operation and decreased significantly from week one to the 1st month postoperative (84.62% & 65.38%, P=0.041). TVT-O operation showed a high success rate in treatment of USI in obese patients without affecting the voiding function of the bladder as proven by the uroflowmetry. The main postoperative complaint was the groin pain which significantly improved after one month. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Sealing maxillary titanium obturators with removable flexible caps.

    PubMed

    Reitemeier, Bernd; Schaal, Wolfgang; Wolf, Annette; Walter, Michael

    2016-03-01

    Maxillary obturator prostheses with hollow metal obturators can be made of titanium to reduce weight. To prevent perforation of the hollow obturator during modifications, the obturator is slightly undersized and covered with a replaceable cap. This cap is made of a soft copolymer to facilitate uncomplicated modifications in the resection area and to improve function. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Palatal obturators in patients after maxillectomy.

    PubMed

    Cardelli, P; Bigelli, E; Vertucci, V; Balestra, F; Montani, M; DE Carli, S; Arcuri, C

    2014-01-01

    Prosthodontic management of palatal defects is fundamental to improve patient's life undergoing to a maxillary surgical treatment. A lot of maxillary defects are a direct consequence of surgical treatment of malformations, neoplasms or trauma. The obturators are prosthesis used to close palatal defects after maxillectomy, to restore masticatory function and to improve speech. The primary goals of the obturator prosthesis are to preserve the remaining teeth and tissue and to provide comfort, function, and aesthetics to the patients. Different materials and retention methods are a characteristic of new types of obturators.

  1. Palatal obturators in patients after maxillectomy

    PubMed Central

    CARDELLI, P.; BIGELLI, E.; VERTUCCI, V.; BALESTRA, F.; MONTANI, M.; DE CARLI, S.; ARCURI, C.

    2014-01-01

    SUMMARY Prosthodontic management of palatal defects is fundamental to improve patient’s life undergoing to a maxillary surgical treatment. A lot of maxillary defects are a direct consequence of surgical treatment of malformations, neoplasms or trauma. The obturators are prosthesis used to close palatal defects after maxillectomy, to restore masticatory function and to improve speech. The primary goals of the obturator prosthesis are to preserve the remaining teeth and tissue and to provide comfort, function, and aesthetics to the patients. Different materials and retention methods are a characteristic of new types of obturators. PMID:25992263

  2. The comparison of an inexpensive-modified transobturator vaginal tape versus TVT-O procedure for the surgical treatment of female stress urinary incontinence.

    PubMed

    Zhang, Yan; Jiang, Min; Tong, Xiao-Wen; Fan, Bo-Zhen; Li, Huai-Fang; Chen, Xin-Liang

    2011-09-01

    To compare the safety and efficacy of an inexpensive-modified transobturator vaginal tape procedure with the transobturator tension-free vaginal tape (TVT-O) procedure for the surgical treatment of female stress urinary incontinence (SUI). Patients with SUI were randomly allocated to either the test group receiving the inexpensive-modified transobturator vaginal tape procedure or the control group receiving the GYNECARE TVT-O procedure. Treatment outcomes and Quality-of-life scores were recorded and analyzed between two groups. A total of 156 patients were enrolled in this trial. Eighty patients underwent the modified transobturator vaginal tape procedure. Among them 75(93.8%) were cured and 5(6.2%) were improved. The rest of the 76 patients underwent the GYNECARE TVT-O procedure with a 92% (70 of 76) cure rate and an 8% (6 of 76) improvement rate. No inefficient or aggravated cases occurred in both groups. The success rates between groups had no significant statistic difference (p > 0.05). The operative time, blood loss, hospital stay, and medical cost were significantly lower in the test group (p < 0.01); the increases in Quality-of-life scores were comparable between groups. The modified transobturator vaginal tape procedure is an efficacious and economic surgical treatment for female SUI. Copyright © 2011. Published by Elsevier B.V.

  3. Quality of life in patients with obturator prostheses.

    PubMed

    Riaz, Nabeela; Warriach, Riaz Ahmad

    2010-01-01

    Oral cancer has a profound impact on the quality of life for patients and their families. Functionally, the mouth is an important organ for speech, swallowing, chewing, taste and salivation. These functions become compromised due to surgical ablation of the tumour. Obturator prosthesis is a common prosthdontic rehabilitative option for maxillectomy patients. The purpose of this study was to investigate how patients with maxillofacial defects evaluate their quality of life after maxillectomy and prosthodontic therapy with obturator prostheses. Thirty patients were included in the study (11 female, 19 male). The patients were interviewed by using a standardised questionnaire developed by University of Washington (UW-QOL). The detailed questionnaire was adjusted for obturator patients and internalised most parts of obturator functioning scale (OFS). Quality of life after prosthodontic therapy with obturator prostheses was 54 +/- 22.9% on average. Functioning of the obturator prosthesis, impairment of ingestion, speech and appearance, the extent of therapy, and the existence of pain had significant impact on the quality of life (p<0.005). Orofacial rehabilitation of patients with maxillofacial defects using obturator prostheses is an appropriate treatment modality. To improve the situation of patients prior to and after maxillectomy sufficient information about the treatment, adequate psychological care and speech therapy should be provided.

  4. Obturator externus was larger, while obturator internus size was similar in ballet dancers compared to nondancing athletes.

    PubMed

    Mayes, Susan; Ferris, April-Rose; Smith, Peter; Cook, Jill

    2018-06-02

    To compare the cross-sectional area (CSA) of hip external rotators, obturator externus (OE) and obturator internus (OI), in ballet dancers and nondancing athletes, and evaluate the relationship between obturator muscle size and hip pain. Case-control study. Elite ballet and sport. 33 male and female professional ballet dancers and 33 age and sex-matched athletes. CSA's of OE and OI measured on magnetic resonance imaging (MRI) of one hip. Hip pain was scored with the Copenhagen Hip and Groin Outcome Score (HAGOS): HAGOS pain score of 100 was defined as no pain and a score less than 100 was defined as pain. Participants weight and height. Estimated marginal mean CSA of OE was 14% larger in dancers than athletes (p = 0.01, ηp2 = 0.1); the size of OI was similar (p > 0.05). Men and women in both groups had similar sized OI and OE. There was no interaction between the estimated marginal mean CSA of either obturator and hip pain. It appears that ballet selectively increases muscle size of OE, but not OI. Obturator size was not related to mild hip pain, as OE and OI size was similar in dancers and athletes with and without pain. Copyright © 2018. Published by Elsevier Ltd.

  5. Perioperative complications and early follow-up with 100 TVT-SECUR procedures.

    PubMed

    Neuman, Menahem

    2008-01-01

    Our objective was to evaluate the complications and early follow-up of the tension-free vaginal tape (TVT)-SECUR, a new minimally invasive anti-incontinence operative procedure. A prospective, observational, and consecutive patient series was conducted. Perioperative and 12-month postoperative data were prospectively collected for the first 50 patients against the next consecutive 50 patients, among which TVT-SECUR specific surgical measurements were adopted (Canadian Task Force classification 2). In private hospital operative theatres, the TVT-SECUR operation was performed. Patients with urodynamically proved stress urinary incontinence were enrolled in this study after detailed informed consent was given. The TVT-SECUR, in the hammock shape to mimic the TVT-obturator placement, yet with no skin incisions, required neither bladder catheterization nor intraoperative diagnostic cystoscopy. The clinical and surgical data of 100 consecutive patients with TVT-SECUR were collected prospectively. Two patients had urinary obstructions and needed surgical tape-tension relief. One patient had a 50 mL paravesical self-remitting hematoma. At the first-month postoperative follow-up appointment, the objective therapeutic failure rate for the TVT-SECUR procedure among the 50 patients was 20.0% (10 patients). But when the tape was placed close to the urethra with no space allowed in between, the failure rate in the second patient group went down to 8.0% (4 patients); yet no further postoperative bladder outlet obstruction was diagnosed. Four (8.0%) patients in the first group had vaginal wall penetration with the inserters, requiring withdrawal, reinsertion, and vaginal wall repair. This was avoided with the second patient group by facilitating the inserters' introduction by widening the submucosal tunnel to 12 mm. Six (12.0%) other patients in the first group needed postoperative trimming of a vaginally extruded tape segment, performed in the office with satisfactory results

  6. Injuries of the obturator muscles in professional soccer players.

    PubMed

    Wong-On, Manuel; Turmo-Garuz, Antonio; Arriaza, Rafael; Gonzalez de Suso, Jose Manuel; Til-Perez, Luis; Yanguas-Leite, Xavier; Diaz-Cueli, David; Gasol-Santa, Xavier

    2017-02-10

    Obturator externus and internus muscular tears are uncommon injuries. Only a few case reports exist, mainly in high-level athletes. Our aim is to describe a series of obturator externus and internus muscular tears in professional soccer players. Injury data from four teams from the First Division of the Spanish Soccer League were collected over a total of four seasons. Any soccer player who sustained an injury to either the obturator externus or internus identified on magnetic resonance (MRI) was included. All injured players were treated non-operatively with a goal of returning to play as fast as possible. Sixteen players sustained injuries to the obturator externus and internus during matches or training sessions. The main complaint was anterior hip pain with a physical examination showing pain during internal rotation or external rotation of the flexed hip. The MRI documented 12 muscular tears of the obturator externus, and 4 muscular tears of the obturator internus. All injuries were treated conservatively based on physical therapy, analgesic medications, and underwent a symptoms-based rehabilitation protocol. Mean return to play was 11.5  ±  8.8 days. Although uncommon, tears of the obturator externus and internus occur in professional soccer players. The MRI scan was essential to the location, classification, and evaluation of the injury size. The clinical relevance of our investigation is based on the relatively benign prognosis of these injuries. IV.

  7. Rehabilitation of a One-day-Old Neonate with Cleft Lip and Palate using Palatal Obturator: A Case Report.

    PubMed

    Bansal, Rajesh; Kumar Pathak, Ashish; Bhatia, Baldev; Gupta, Sailesh; Kumar Gautam, Keshav

    2012-05-01

    Feeding a neonate with a complete cleft lip and palate is difficult pursuit due to communication between oral cavity and nasal cavity. A multidisciplinary approach is required to manage the complex problems involved in case of such neonates and their families. Present case is of a 1-day-old neonate having complete bilateral cleft lip and palate for which palatal obturator was constructed. A stepwise simple, easy and uncomplicated procedure for making accurate impressions, maxillary cast and fabrication of palatal obturator in infants with cleft lip and palate has been presented. The objective to present this case report is to emphasize the fact that how these palatal obturators /plates help in feeding, speech/language development, presurgical orthopedics and prevent other associated otorhinolaryngeal problems. How to cite this article: Bansal R, Pathak AK, Bhatia B, Gupta S, Gautam KK. Rehabilitation of a One-day Old Neonate with Cleft Lip and Palate using Palatal Obturator: A Case Report. Int J Clin Pediatr Dent 2012;5(2):145-147.

  8. Transfascial vaginal tape (TFT): a simple, safe and cost-effective procedure for stress urinary incontinence. A preliminary study.

    PubMed

    Foglia, Giovanni; Mistrangelo, Emanuela; Lijoi, Davide; Alessandri, Franco; Ragni, Nicola

    2007-07-01

    To analyse prospectively the effectiveness of a new simple, minimally invasive, and cost-effective technique for the treatment of female urinary stress incontinence: the transfascial vaginal tape (TFT). In a prospective study, we enrolled 45 women undergoing TFT with or without hysterectomy and/or another pelvic reconstructive procedure between 1st December 2003 and 31st December. TFT consists of a tension-free urethrosuspension using a sling located at the mid-urethral level and placed laterally in the endopelvic fascia previously perforated. Follow-up evaluations were established at 3 and 6 months and at 1 year after the operation. During each follow-up, women underwent cough stress test and they answered to the "Incontinence quality of life questionnaire" (I-QOL), to the Patient Global Impression of Severity (PGI-S) and of Improvement (PGI-I) questions. Thirty-nine patients (88.9%) had a follow-up examination 1 year after surgery. Of these, 30 (76.9%) were defined cured, 6 (15.4%) improved and 3 (7.7%) failed. TFT procedure can be considered a simple, safe and cost-effective procedure for the treatment of stress urinary incontinence and can be an alternative to tension-free vaginal tape or transobturator route for sub-urethral tape procedures.

  9. The TVT-obturator surgical procedure for the treatment of female stress urinary incontinence: a clinical update.

    PubMed

    Waltregny, David; de Leval, Jean

    2009-03-01

    Six years ago, the inside-out transobturator tape TVT-O procedure was developed for the surgical treatment of female stress urinary incontinence (SUI) with the aim of minimizing the risk of urethra and bladder injuries and ensuring minimal tissue dissection. Initial feasibility and efficacy studies suggested that the TVT-O procedure is associated with high SUI cure rates and low morbidity at short term. A recent analysis of medium-term results indicated that the TVT-O procedure is efficient, with maintenance, after a 3-year minimum follow-up, of cure rates comparing favorably with those reported for TVT. No late complications were observed. As of July 2008, more than 35 clinical papers, including ten randomized trials and two national registries, have been published on the outcome of the TVT-O surgery. Results from these studies have confirmed that the TVT-O procedure is safe and as efficient as the TVT procedure, at least in the short/medium term.

  10. Determination of a Central Avascular Triangle within the Obturator Foramen: A Radioanatomic Study

    PubMed Central

    Nyangoh Timoh, Krystel; Bader, Georges; Fauconnier, Arnaud; Barrau, Vincent; Delmas, Vincent; Touboul, Cyril

    2015-01-01

    Purpose To map the vascular anatomy of the obturator foramen using fixed anatomic landmarks. Method Twenty obturator regions were dissected in 10 fresh female cadavers after vascular blue dye injection in five cadavers (50%). Furthermore, 104 obturator regions were reconstructed by angiotomodensitometry from 52 women under investigation for suspected arterial disease. The anatomy of the obturator region was mapped by measuring the distance of vascular structures from the middle of the two branches of the ischiopubic bone, which were used as fixed landmarks. Results The bifurcation of the obturator artery was at a mean (SD) distance of 30.0 mm (4.5) from the middle of the ischiopubic branch (MISP). The anterior branch of the obturator vessels was 15.2 mm (10.1) from the MISP. The posterior branch of the obturator vessels was 5.5 mm (4.0) and 23.6 mm (8.7) from the middle of the outer edge of the obturator foramen (MOE) and the MISP, respectively. Using 5° and 95° percentiles of these measurements we defined a central avascular triangle. Conclusions Our data show that, beyond inter-individual variations, a central triangular avascular area can be identified in the obturator foramen between the posterior and anterior obturator artery using fixed landmarks. PMID:26624993

  11. Measurement of the percentage of root filling in oval-shaped canals obturated with Thermafil Obturators and Beefill 2in1: In vitro study.

    PubMed

    Faus-Llácer, Vicente; Collado-Castellanos, Nicolás; Alegre-Domingo, Teresa; Dolz-Solsona, María; Faus-Matoses, Vicente

    2015-04-01

    The aim of the study was to measure the percentage of root canal fillings in long oval canals obturated with thermoplasticized gutta-percha techniques, Beefill 2in1® and Thermafil Obturators®. Fifty four mandibular incisors were selected after bucco-lingual and mesio-distal radiographs showed at 5 mm from apex an internal long:short diameter ≥2. Teeth were instrumented with Protaper Universal and divided in two groups of 27. Group 1 was obturated with Thermafil Obturators® and group 2 with Beefill 2in1®. Two horizontal sections were cut at 5 and 7 mm from the apex and photographed in a stereo-microscope. The total area of the canal and filled canal in cross-sections were measured with AutoCad and the percentages of gutta-percha-sealer and voids in the canal were obtained. Both systems achieved high percentage of filled canal, Thermafil 96.8% and Beefill 2in1 98.9%. The percentages of voids in both groups were very low. No significant differences were found between the two groups . The percentage obtained at 5 and 7 mm from the apex in both groups showed no significant difference. The percentages of filled canal (gutta-percha-sealer) were high and these two thermoplasticized techniques are suitable for long oval canals obturation. Key words:Long oval canal, oval canal, thermoplasticized obturation.

  12. Speech rehabilitation of maxillectomy patients with hollow bulb obturator.

    PubMed

    Kumar, Pravesh; Jain, Veena; Thakar, Alok

    2012-09-01

    To evaluate the effect of hollow bulb obturator prosthesis on articulation and nasalance in maxillectomy patients. A total of 10 patients, who were to undergo maxillectomy, falling under Aramany classes I and II, with normal speech and hearing pattern were selected for the study. They were provided with definitive maxillary obturators after complete healing of the defect. The patients were asked to wear the obturator for six weeks and speech analysis was done to measure changes in articulation and nasalance at four different stages of treatment, namely, preoperative, postoperative (after complete healing, that is, 3-4 months after surgery), after 24 hours, and after six weeks of providing the obturators. Articulation was measured objectively for distortion, addition, substitution, and omission by a speech pathologist, and nasalance was measured by Dr. Speech software. The statistical comparison of preoperative and six weeks post rehabilitation levels showed insignificance in articulation and nasalance. Comparison of post surgery complete healing with six weeks after rehabilitation showed significant differences in both nasalance and articulation. Providing an obturator improves the speech closer to presurgical levels of articulation and there is improvement in nasality also.

  13. Speech Rehabilitation of Maxillectomy Patients with Hollow Bulb Obturator

    PubMed Central

    Kumar, Pravesh; Jain, Veena; Thakar, Alok

    2012-01-01

    Aim: To evaluate the effect of hollow bulb obturator prosthesis on articulation and nasalance in maxillectomy patients. Materials and Methods: A total of 10 patients, who were to undergo maxillectomy, falling under Aramany classes I and II, with normal speech and hearing pattern were selected for the study. They were provided with definitive maxillary obturators after complete healing of the defect. The patients were asked to wear the obturator for six weeks and speech analysis was done to measure changes in articulation and nasalance at four different stages of treatment, namely, preoperative, postoperative (after complete healing, that is, 3-4 months after surgery), after 24 hours, and after six weeks of providing the obturators. Articulation was measured objectively for distortion, addition, substitution, and omission by a speech pathologist, and nasalance was measured by Dr. Speech software. Results: The statistical comparison of preoperative and six weeks post rehabilitation levels showed insignificance in articulation and nasalance. Comparison of post surgery complete healing with six weeks after rehabilitation showed significant differences in both nasalance and articulation. Conclusion: Providing an obturator improves the speech closer to presurgical levels of articulation and there is improvement in nasality also. PMID:23440022

  14. Measurement of the percentage of root filling in oval-shaped canals obturated with Thermafil Obturators and Beefill 2in1: In vitro study

    PubMed Central

    Collado-Castellanos, Nicolás; Alegre-Domingo, Teresa; Dolz-Solsona, María; Faus-Matoses, Vicente

    2015-01-01

    Background The aim of the study was to measure the percentage of root canal fillings in long oval canals obturated with thermoplasticized gutta-percha techniques, Beefill 2in1® and Thermafil Obturators®. Material and Methods Fifty four mandibular incisors were selected after bucco-lingual and mesio-distal radiographs showed at 5 mm from apex an internal long:short diameter ≥2. Teeth were instrumented with Protaper Universal and divided in two groups of 27. Group 1 was obturated with Thermafil Obturators® and group 2 with Beefill 2in1®. Two horizontal sections were cut at 5 and 7 mm from the apex and photographed in a stereo-microscope. The total area of the canal and filled canal in cross-sections were measured with AutoCad and the percentages of gutta-percha-sealer and voids in the canal were obtained. Results Both systems achieved high percentage of filled canal, Thermafil 96.8% and Beefill 2in1 98.9%. The percentages of voids in both groups were very low. No significant differences were found between the two groups . The percentage obtained at 5 and 7 mm from the apex in both groups showed no significant difference. Conclusions The percentages of filled canal (gutta-percha-sealer) were high and these two thermoplasticized techniques are suitable for long oval canals obturation. Key words:Long oval canal, oval canal, thermoplasticized obturation. PMID:26155350

  15. Use of a magnetic attachment to retain an obturator prosthesis for an osseous defect.

    PubMed

    Kawamoto, Shin-ichiro; Hamamura, Syunichi; Kawahara, Hideki; Nishi, Yasuhiro; Nagaoka, Eiichi

    2009-06-01

    Tooth loss accompanied by a massive defect of the alveolar bone can cause serious problems such as food deposit and esthetic impairment. This report describes procedures for the fabrication of an osseous defect obturator prosthesis connected to a fixed partial denture by a magnetic attachment along with the clinical outcome.

  16. A Conservative Method of Retaining an Interim Obturator for a Total Maxillectomy Patient

    PubMed Central

    Bettie, Nirmal Famila

    2017-01-01

    Interim obturators are indicated during the postsurgical phases. It promotes surgical healing and serves as a temporary prosthesis to rehabilitate a patient with intra-oral surgical defect. Retention is gained by wiring, surgical suturing, and other noninvasive methods to enable functional rehabilitation and easy replacement with a permanent obturator. Interim obturators serve as an easy guide for replacing with definitive obturators by indicating prosthesis extensions and the required method of retention. A more conservative and noninvasive method of retaining an interim obturator for a maxillectomy patient is described in this case report. PMID:29284985

  17. A Conservative Method of Retaining an Interim Obturator for a Total Maxillectomy Patient.

    PubMed

    Bettie, Nirmal Famila

    2017-11-01

    Interim obturators are indicated during the postsurgical phases. It promotes surgical healing and serves as a temporary prosthesis to rehabilitate a patient with intra-oral surgical defect. Retention is gained by wiring, surgical suturing, and other noninvasive methods to enable functional rehabilitation and easy replacement with a permanent obturator. Interim obturators serve as an easy guide for replacing with definitive obturators by indicating prosthesis extensions and the required method of retention. A more conservative and noninvasive method of retaining an interim obturator for a maxillectomy patient is described in this case report.

  18. Archive Data Tape Library (ADTL)

    DOT National Transportation Integrated Search

    1983-01-01

    The purpose of this directory is to describe the procedures involved in using the ADTL as well as to identify and describe the data tapes contained in the ADTL. This directory provides a listing of the data tapes contained in the ADTL by mode of tran...

  19. Stress analysis in oral obturator prostheses: imaging photoelastic

    NASA Astrophysics Data System (ADS)

    Pesqueira, Aldiéris Alves; Goiato, Marcelo Coelho; dos Santos, Daniela Micheline; Haddad, Marcela Filié; Andreotti, Agda Marobo; Moreno, Amália

    2013-06-01

    Maxillary defects resulting from cancer, trauma, and congenital malformation affect the chewing efficiency and retention of dentures in these patients. The use of implant-retained palatal obturator dentures has improved the self-esteem and quality of life of several subjects. We evaluate the stress distribution of implant-retained palatal obturator dentures with different attachment systems by using the photoelastic analysis images. Two photoelastic models of the maxilla with oral-sinus-nasal communication were fabricated. One model received three implants on the left side of the alveolar ridge (incisive, canine, and first molar regions) and the other did not receive implants. Afterwards, a conventional palatal obturator denture (control) and two implant-retained palatal obturator dentures with different attachment systems (O-ring; bar-clip) were constructed. Models were placed in a circular polariscope and a 100-N axial load was applied in three different regions (incisive, canine, and first molar regions) by using a universal testing machine. The results were photographed and analyzed qualitatively using a software (Adobe Photoshop). The bar-clip system exhibited the highest stress concentration followed by the O-ring system and conventional denture (control). Images generated by the photoelastic method help in the oral rehabilitator planning.

  20. Comparison of different obturation techniques for primary molars by digital radiography.

    PubMed

    Memarpour, Mahtab; Shahidi, Shoaleh; Meshki, Razieh

    2013-01-01

    The purpose of this study was to compare six methods of root canal filling in primary mandibular second molars via digital radiography. A total of 239 canals were prepared and obturated with zinc-oxide eugenol paste. Obturation methods compared were: anesthetic syringe; NaviTip syringe; pressure syringe; tuberculin syringe; lentulo spiral; and packing with a plugger. The canals were evaluated in photostimulated phosphor radiographs for length of obturation, presence of voids, and number and sum of void sizes. The data were analyzed using chi-square, Kruskal-Wallis and Mann-Whitney tests. There were significant differences between all groups in the length of obturation (P>.01) and presence of voids (P<.001). The lentulo and tuberculin syringe groups, respectively, showed the best and worst results for length of obturation. Significant differences were also found in the number of voids (P<.001) and mean sum of void sizes in the coronal (P<.001) and middle third (P=.003). For the number and size of the voids, the NaviTip group showed the best results. Lentulo produced the best results in terms of length of obturation, while NaviTip syringe produced the best results in controlling paste extrusion from the apical foramen and having the smallest void size and lowest number of voids.

  1. Influence of irrigation and obturation techniques on artificial lateral root canal filling capacity.

    PubMed

    Silva, Emmanuel J; Herrera, Daniel R; Souza-Júnior, Eduardo J; Teixeira, João M

    2013-01-01

    The aim of this study was to evaluate the influence of two different irrigation protocols on artificial lateral root canal filling capacity using different obturation techniques. Sixty single-root human teeth were used. Two artificial lateral canals were created in the apical third. Root canals were instrumented up to a 45 K-file to the working length. Before each file, root canals were irrigated either with 2 mL of 2.5% NaOCl or 2% chlorhexidine gel with further irrigation with saline solution and 3 mL of 17% EDTA. Specimens were randomly divided into three groups according to the obturation technique: (1) lateral compaction technique; (2) Tagger hybrid technique; and (3) thermoplasticized technique using BeeFill 2 in 1. All groups used AH Plus as the root canal sealer. The specimens were decalcified and cleared in methyl salicylate. The total length of lateral canals was observed under X30 magnification with a stereomicroscope and measured on the buccal and lingual root surfaces using Leica IM50 software. The data were submitted to ANOVA and Tukey test (p < 0.05). Among the obturation techniques, BeeFill 2 in 1 showed deeper penetration into all lateral canals than the lateral compaction or Tagger hybrid techniques (p < 0.05). The lateral compaction group showed the worst results (p < 0.05). Irrigants did not affect the outcome; there was no difference between NaOCl and chlorhexidine when the same obturation technique was used (p > 0.05). Regardless of the irrigant used during endodontic procedures, the thermoplasticized techniques showed higher penetration behavior for filling artificial lateral canals than the lateral compaction technique.

  2. Sealing properties of one-step root-filling fibre post-obturators vs. two-step delayed fibre post-placement.

    PubMed

    Monticelli, Francesca; Osorio, Raquel; Toledano, Manuel; Ferrari, Marco; Pashley, David H; Tay, Franklin R

    2010-07-01

    The sealing properties of a one-step obturation post-placement technique consisting of Resilon-capped fibre post-obturators were compared with a two-step technique based on initial Resilon root filling following by 24h-delayed fibre post-placement. Thirty root segments were shaped to size 40, 0.04 taper and filled with: (1) InnoEndo obturators; (2) Resilon/24h-delayed FibreKor post-cementation. Obturator, root filling and post-cementation procedures were performed using InnoEndo bonding agent/dual-cured root canal sealer. Fluid flow rate through the filled roots was evaluated at 10psi using a computerised fluid filtration model before root resection and after 3 and 9mm apical resections. Fluid flow data were analysed using two-way repeated measures ANOVA and Tukey test to examine the effects of root-filling post-placement techniques and root resection lengths on fluid leakage from the filled canals (alpha=0.05). A significantly greater amount of fluid leakage was observed with the one-step technique when compared with two-step technique. No difference in fluid leakage was observed among intact canals and canals resected at different lengths for both materials. The seal of root canals achieved with the one-step obturator is less effective than separate Resilon root fillings followed by a 24-h delay prior to the fibre post-placement. Incomplete setting of the sealer and restricted relief of polymerisation shrinkage stresses may be responsible for the inferior seal of the one-step root-filling/post-restoration technique. Copyright 2010 Elsevier Ltd. All rights reserved.

  3. Volumetric Evaluation of Different Obturation Techniques in Primary Teeth Using Spiral Computed Tomography.

    PubMed

    Nagaveni, N B; Yadav, Sneha; Poornima, P; Reddy, Vv Subba; Roshan, N M

    Various obturation techniques have been evaluated for better filling of the root canals in primary teeth using different methods. Spiral Computed Tomography (SCT) is a new revolution in the pediatric endodontics for assessment of quality of the obturation from 3 dimensions. To evaluate the efficiency of 5 different obturation methods in delivering the filling material into the canals of primary teeth using Spiral Computed Tomography scan. A total of 50 canals of primary teeth were prepared, divided into 5 groups with 10 canals in each group and obturated with Zinc Oxide Eugenol cement using 5 different obturation techniques such as Local anesthetic syringe, Tuberculin syringe, Endodontic plugger, hand held Lentulo-spiral, and Lentulo-spiral mounted on slow speed hand piece. The pre and post obturation volume and finally the Percentage of Obturated Volume (POV) were calculated using SCT scan for each group. The data obtained was statistically analyzed using One-way Analysis of Variance (ANOVA) and Tukey's post-hoc test. Lentulo-spiral hand held showed highest POV value followed by Lentulospiral mounted to hand piece, Tuberculin syringe and Endodontic plugger; whereas Anesthetic syringe had least POV (P < 0.05). Lentulo-spiral hand held is the best obturating technique among the 5 groups evaluated as the canals of this group showed maximum percentage of filled material. However, a further study with large sample size is highly essential.

  4. Enhanced retention of a maxillofacial prosthetic obturator using precision attachments: Two case reports

    PubMed Central

    Murat, Sema; Gurbuz, Ayhan; Isayev, Abulfaz; Dokmez, Bahadir; Cetin, Unsun

    2012-01-01

    The majority of maxillary defects can be rehabilitated with conventional simple obturator prosthesis. However, inadequate retention, stability and support may be associated with the use of an obturator. Precision attachments have been used to retain obturators for some time. The use of precision attachments in a dentate maxillectomy patient can yield significant functional improvement while maintaining the obturator’s aesthetic advantages. This clinical report describes the prosthetic rehabilitation of two maxillary defects with an obturator retained using extracoronal resilient precision attachments. PMID:22509126

  5. The effect of exercise and time on the height and width of the medial longitudinal arch following the modified reverse-6 and the modified augmented low-dye taping procedures.

    PubMed

    Cornwall, Mark W; McPoil, Thomas G; Fair, Austin

    2014-10-01

    No evidence exits regarding the magnitude of the change in foot posture following the "modified reverse-6" (MR6) taping procedure, either alone or in combination with the "low-dye" (LD) taping technique. The purpose of this study was to investigate the change in the height and width of the midfoot after application of the MR6 and the MR6 plus the LD (MR6+LD) taping technique and determine how long those changes last. Eleven individuals (2 female and 9 male) were recruited for this study and were tested under each of two experimental conditions, the MR6 and the MR6+LD taping technique. The order of testing for the two conditions was randomly determined. For each condition, the height and width of the midfoot at 50% of each subject's foot length was initially measured and then again immediately following the application of the tape. These measurements were repeated four hours later immediately prior to running two miles on a treadmill, again immediately after running, and finally after another four hours. The dorsal arch height increased significantly with both the MR6 and MR6+LD taping, but only the MR6+LD remained statistically greater after four hours, a bout of exercise and again at the end of the day. The mean width of the midfoot significantly decreased with both taping procedures. The change in the width of the midfoot remained significantly decreased in both taping conditions after exercise and throughout the day. Both taping procedures are able to significantly change the height and width of the medial longitudinal arch of the foot, but the change lasted longer when the two taping procedures were combined. Level 3, Prospective Cohort Study.

  6. Obturator hernia: a rare case of acute mechanical intestinal obstruction.

    PubMed

    Aydin, Ibrahim; Yucel, Ahmet Fikret; Pergel, Ahmet; Sahin, Dursun Ali

    2013-01-01

    Obturator hernia is a rare type of pelvic hernia which generally occurs in elderly patients with accompanying diseases. Because it is difficult to diagnose before surgery, the morbidity and mortality rates for obturator hernia are high. The most common symptom is strangulation combined with mechanical intestinal obstruction.

  7. Obturator Hernia: A Rare Case of Acute Mechanical Intestinal Obstruction

    PubMed Central

    Yucel, Ahmet Fikret; Pergel, Ahmet; Sahin, Dursun Ali

    2013-01-01

    Obturator hernia is a rare type of pelvic hernia which generally occurs in elderly patients with accompanying diseases. Because it is difficult to diagnose before surgery, the morbidity and mortality rates for obturator hernia are high. The most common symptom is strangulation combined with mechanical intestinal obstruction. PMID:23738179

  8. Inflatable hollow obturator prostheses for patients undergoing an extensive maxillectomy: a case report

    PubMed Central

    Hou, Yue-Zhong; Huang, Zhi; Ye, Hong-Qiang; Zhou, Yong-Sheng

    2012-01-01

    The presence of a large palatal or maxillary defect after partial or total maxillectomy for tumor, trauma or congenital deformation poses a challenge to prosthodontists, particularly when the use of an implant cannot be considered. This case report described the use of an air valve in a hollow silicone obturator to manufacture an inflatable obturator that could be extended further into undercut area to retain itself. The inflatable obturator exhibited adequate retention, stability and border sealing, thereby improving the masticatory, pronunciation and swallowing functions of patients. It may be a suitable alternative treatment option to an implant-retained obturator. PMID:22653550

  9. 21 CFR 868.5650 - Esophageal obturator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) Identification. An esophageal obturator is a device inserted through a patient's mouth to aid ventilation of the patient during emergency resuscitation by occluding (blocking) the esophagus, thereby permitting positive...

  10. Casting Of Multilayer Ceramic Tapes

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr.

    1991-01-01

    Procedure for casting thin, multilayer ceramic membranes, commonly called tapes, involves centrifugal casting at accelerations of 1,800 to 2,000 times normal gravitational acceleration. Layers of tape cast one at a time on top of any previous layer or layers. Each layer cast from slurry of ground ceramic suspended in mixture of solvents, binders, and other components. Used in capacitors, fuel cells, and electrolytic separation of oxygen from air.

  11. Transfer of obturator nerve for femoral nerve injury: an experiment study in rats.

    PubMed

    Meng, Depeng; Zhou, Jun; Lin, Yaofa; Xie, Zheng; Chen, Huihao; Yu, Ronghua; Lin, Haodong; Hou, Chunlin

    2018-07-01

    Quadriceps palsy is mainly caused by proximal lesions in the femoral nerve. The obturator nerve has been previously used to repair the femoral nerve, although only a few reports have described the procedure, and the outcomes have varied. In the present study, we aimed to confirm the feasibility and effectiveness of this treatment in a rodent model using the randomized control method. Sixty Sprague-Dawley rats were randomized into two groups: the experimental group, wherein rats underwent femoral neurectomy and obturator nerve transfer to the femoral nerve motor branch; and the control group, wherein rats underwent femoral neurectomy without nerve transfer. Functional outcomes were measured using the BBB score, muscle mass, and histological assessment. At 12 and 16 weeks postoperatively, the rats in the experimental group exhibited recovery to a stronger stretch force of the knee and higher BBB score, as compared to the control group (p < 0.05). The muscle mass and myofiber cross-sectional area of the quadriceps were heavier and larger than those in the control group (p < 0.05). A regenerated nerve with myelinated and unmyelinated fibers was observed in the experimental group. No significant differences were observed between groups at 8 weeks postoperatively (p > 0.05). Obturator nerve transfer for repairing femoral nerve injury was feasible and effective in a rat model, and can hence be considered as an option for the treatment of femoral nerve injury.

  12. THE EFFECTS OF VIDEO-TAPING PROCEDURES IN AN EXPERIMENTAL READING PROGRAM.

    ERIC Educational Resources Information Center

    SCHWARTZ-LITTMANN, CAROLE

    THE EXPERIMENTAL USE OF VIDEO AND TAPE RECORDINGS IN TEACHING THREE NEUROLOGICALLY DISABLED BOYS AGED 8, 9, AND 10 TO READ IS REPORTED. EXPERIENCE CHARTS WERE USED TO PRESENT BOTH UNCONTROLLED AND CONTROLLED VOCABULARY. THREE SPACES VIDEO-TAPED DEMONSTRATIONS WITH THE CHILDREN WERE USED TO DIAGNOSE PROGRESS AND AS MOTIVATIONAL DEVICES. THE…

  13. Clinical Assessment of Various Obturating Techniques for Primary Teeth: A Comparative Study

    PubMed Central

    Tandon, Sandeep; Vijay, Akshat; Kalia, Garima; Rathore, Khushboo

    2017-01-01

    Introduction Lifelong preservation of tooth in a healthy state is the ultimate goal of dentistry. Premature loss of primary teeth is common due to caries, dental trauma or other causes. As the primary teeth are the best space maintainers, teeth with infected pulps should be retained until exfoliation, whenever possible. Aim The purpose of this in vivo study was to evaluate and compare the efficacy of different obturating methods used in primary teeth. Materials and Methods Forty one patients aged four to nine years with a total of 60 teeth were selected. Out of the 60 teeth, 32 were primary mandibular first molars and 28 were primary mandibular second molars, the sample was randomly divided into three groups. Disposable syringe, lentulo spiral and past inject were used for obturation. Postoperative evaluation was done for; quality of canal obturation, presence of voids using postoperative radiographs following obturation of teeth. The data were analysed to assess the success rate of the three methods used for obturation using Chi-square test. Results Among the three groups of the study, past inject exhibited the maximum number of optimally filled canals. Maximum number of underfilled canals was found with lentulospiral, and the maximum number of overfilled canals was seen with disposable syringe. Least number of voids was observed in canals filled with the past inject technique and disposable syringe. Conclusion The results suggest that the most successful technique for obturation of primary teeth was past inject. PMID:28893042

  14. Quality of life after maxillectomy and prosthetic obturator rehabilitation.

    PubMed

    Chigurupati, Radhika; Aloor, Neelam; Salas, Richard; Schmidt, Brian L

    2013-08-01

    Surgical resection of midface neoplasms and subsequent reconstruction have been shown to have significant negative effects on quality of life (QOL). The purpose of this pilot study was to assess individuals' health-related QOL after maxillectomy and reconstruction with a prosthetic obturator. The QOL of 25 of 43 patients who underwent maxillectomy and prosthetic obturator reconstruction at the University of California-San Francisco was assessed using 3 questionnaires: University of Washington Quality of Life version 4 (UWQOL), Obturator Functioning Scale (OFS), and Mental Health Inventory (MHI). The response rate to the QOL questionnaires was 92% (23 of 25 patients). Time elapsed from maxillectomy and prosthetic obturator reconstruction to the QOL survey response ranged from 0.3 to 6.6 years (mean, 2.7 years; standard deviation [SD], 1.9 years). The post-treatment mean QOL scores were 77.3 (SD, 13.6) for UWQOL, 72.0 (SD, 12.6) for OFS, and 4.5 (SD, 0.9) for Mental Health Inventory. Individuals who received adjuvant radiation scored lower for speech and appearance (OFS, P = .05, P = .03, respectively) as well as for saliva and overall QOL (UWQOL, P = .02, P = .08, respectively). There was a strong correlation between QOL scores in OFS and UWQOL questionnaires (r = 0.78, P < .001). The results of this pilot study suggest that postoperative radiation therapy was the strongest variable affecting QOL in patients with maxillectomy and prosthetic obturator reconstruction. There is further need for a multicenter trial with a larger sample to identify how factors affecting QOL of patients after maxillectomy might influence the choice of reconstruction. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Oral function after maxillectomy and reconstruction with an obturator.

    PubMed

    Kreeft, A M; Krap, M; Wismeijer, D; Speksnijder, C M; Smeele, L E; Bosch, S D; Muijen, M S A; Balm, A J M

    2012-11-01

    Maxillectomy defects can be reconstructed by a prosthetic obturator or (free) flap transfer, but there is no consensus about the optimal method. This study evaluated 32 maxillectomy patients with prosthetic obturation regarding function (mastication, subjective oral and swallowing complaints and maximal mouth opening). Outcomes were related to the extent of the resection (Brown maxillectomy classification), dentition and history of adjuvant radiotherapy. Maxillectomy defects ranged from 2-1 to 4B on the Brown classification, and most had a defect graded as 2-A or 2-B. Mean mixing ability test after 10 chewing strokes was 24.2 and after 20 chewing strokes 19.7, which compares to edentulous healthy individuals. None of the outcomes was influenced by Brown classification. Radiotherapy negatively influenced mean maximal mouth opening (29.1mm versus 40.9 mm, p=0.017) and subjective outcomes. Edentate obturated patients had worse outcomes than dentate patients, measured by mixing ability test and questionnaire. In conclusion, mastication after obturator reconstruction of a maxillectomy defect is comparable to mastication with full dentures. Size of the maxillectomy defect did not significantly influence functional outcome, but adjuvant radiotherapy resulted in worse mouth opening and self-reported oral and swallowing problems. Residual dentition had a positive influence on mastication and subjective outcomes. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  16. Tape functionality: position, change in shape, and outcome after TVT procedure--mid-term results.

    PubMed

    Kociszewski, Jacek; Rautenberg, Oliver; Kolben, Sebastian; Eberhard, Jakob; Hilgers, Reinhard; Viereck, Volker

    2010-07-01

    This study evaluates the relevance of the tape position and change in shape (tape functionality) under in vivo conditions for mid-term outcome. Changes in the sonographic tension-free vaginal tape (TVT) position relative to the percentage urethral length and the tape-urethra distance were determined after 6 and 48 months in 41 women with stress urinary incontinence. At 48 months, 76% (31/41) of women were cured, 17% (7/41) were improved, and 7% (3/41) were failures. Disturbed bladder voiding was present in 12% (5/41), de novo urge incontinence in 7% (3/41). The median TVT position was at 63% of urethral length. Median tape-urethra distance was 2.7 mm, ranging from 2.9 mm in continent patients without complications to 1.1 mm in those with obstructive complications. Patients with postoperative urine loss had a median distance of 3.9 mm. The tape was stretched at rest and C-shaped during straining in 15 of 41 women (37%) at 48 months (all continent). Patients with this tape functionality at 6 months were also cured at 48 months in 86% of cases (19/22), and only 14% (3/22) showed recurrent incontinence. Mid-term data suggest an optimal outcome if the tape is positioned at least 2 mm from the urethra at the junction of the middle and distal thirds. Patients with optimal tape functionality at 6 months are likely to show mid-term therapeutic success.

  17. [MORPHOLOGICAL CHANGES OF THE LIVER IN OBTURATION JAUNDICE, CAUSED BY CHOLEDOCHOLITHIASIS, DEPENDING ON ITS DURATION].

    PubMed

    Sipliviy, V A; Yevtushenko, D V; Naumova, O V; Andreyeshchev, S A; Yevtushenko, A V

    2016-02-01

    Abstract The results of surgical treatment of 184 patients for obturation jaundice, caused by choledocholithiasis, were analyzed. Morphological changes of the liver were studied in 20 patients. There were three groups of patients delineated, depending on the obturation jaundice duration: up to 7 days, from 8 to 14 days, more than 15 days, and also a group of patients after the bile outflow restoration. The obturation jaundice occurrence in choledocholithiasis is accompanied by significant morphological changes in the liver, severity of which is enhancing while the obturation jaundice persistence increasing. While persistence of obturation jaundice through 8 days and more the connective tissue volume is enhancing, a relative volume of hepatocytes is reducing and a stromal-parenchymatous index is increasing. The bile outflow restoration secures significant reduction of intensity of alterative and inflammatory changes in hepatic parenchyma, as well as activation of reparative processes in the tissue. In cholangitis, caused by P. aeruginosa and E. coli, according to morphological investigations data, in the liver a diffuse purulent cholangitis on background of chronic changes in accordance to duration of the obturation jaundice persists.

  18. Comparison of two vertical condensation obturation techniques: Touch 'n Heat modified and System B.

    PubMed

    Silver, G K; Love, R M; Purton, D G

    1999-08-01

    The aims of this study were firstly to compare the area of canal occupied by gutta-percha, sealer or voids using the System B heating device with that obtained by a modified vertical condensation technique using the Touch 'n Heat: and secondly to compare the temperature changes at the root canal wall and external root surface during obturation with the above techniques. Forty-five resin blocks, each with a standardized, simulated, prepared main root canal and five lateral canals, were assigned to three equal experimental groups. The canals were obturated using either the System B technique at two different temperature settings, or vertical condensation with a Touch 'n Heat instrument as the heat source. A heat transfer model was used to simultaneously record internal and external root surface temperature elevations during obturation by the three techniques. Data were analysed using unpaired Student's t-test and Mann-Whitney U-test. Both obturation techniques produced root fillings consisting of over 90% gutta-percha at most levels, although the percentages of sealer and voids 2-3 mm from the working length following System B obturation were higher than those found following modified vertical condensation. Modified vertical condensation resulted in more gutta-percha in lateral canals. Obturation was accomplished more quickly using the System B, and temperature elevations produced during obturation with the System B were significantly less (P < 0.001) than with vertical condensation. An elevation of external root surface temperature by more than 10 degrees C occurred during vertical condensation. The results suggest that the System B may produce an acceptable obturation and that the use of a Touch 'n Heat source during vertical condensation may result in damage to the periodontium.

  19. Obturator Neuromodulation with Laparoscopic Placement of an Obturator Lead for the Treatment of Intractable Opioid Dependent Chronic Pelvic Pain due to Obturator Neuralgia.

    PubMed

    Marvel, Richard P

    2018-05-12

    Chronic pelvic pain(CPP) is a common condition in women that can have a devastating effect on quality of life. Some of the most severe forms of CPP are related to peripheral nerve injuries causing persistent neuropathic pain. This is a case of a young woman with severe opioid dependent chronic pelvic and right groin pain due to obturator neuralgia. She had failed a multitude of treatments including multiple medications, manual physical therapy, nerve blocks, surgical neurolysis and spinal cord stimulation without significant benefit. She underwent a trial of peripheral neuromodulation of the obturator nerve with laparoscopic placement of a quadripolar lead. During the 6-day trial she had almost complete relief of her pain; therefore, she underwent permanent implantation of an intermittent pulse generator. Over the next 6 months she was completely weaned completely off her chronic opioids. At 23 months post implantation, she had essentially no pain and is no longer on any analgesic, antidepressant or membrane stabilizing medications. Peripheral Neuromodulation has the potential to alleviate pain and significantly improve quality of life in women with longstanding neuropathic chronic pelvic pain who have failed multimodal conservative therapy. Copyright © 2018. Published by Elsevier Inc.

  20. Effect of Post Space Preparation on Apical Obturation Quality of Teeth Obturated with Different Techniques: A Micro-computed Tomographic Study.

    PubMed

    Küçükkaya Eren, Selen; Askerbeyli Örs, Sevinc; Yılmaz, Zeliha

    2017-07-01

    The purpose of this study was to evaluate the obturation quality of root canals filled with different techniques and to determine whether post space preparation had an effect on the quality of apical obturation using micro-computed tomographic (micro-CT) imaging. The root canals of 30 human mandibular premolar teeth were instrumented, and the specimens were divided into 3 groups according to the obturation technique used: cold lateral compaction (CLC), warm vertical compaction (WVC), or single-cone (SC) techniques. The specimens were stored at 37°C and 100% humidity for 1 week. Then, the coronal root filling material was removed in order to create a post space. Micro-CT scans were performed before and after post space preparation for the volumetric analysis of voids and filling materials. Data were analyzed using repeated-measures analysis of variance and Bonferroni tests. The CLC and SC groups showed a significantly greater percentage volume of voids than the WVC group (P < .05), whereas no significant difference was found between the CLC and SC groups before and after post space preparation (P > .05). The post space preparation caused a significant increase in the percentage volume of voids in the CLC and SC groups (P < .05). No significant difference was detected in the percentage volume of voids in the WVC group after post space preparation (P > .05). No root fillings were void free. The WVC group presented the best obturation quality. The post space preparation negatively influenced the apical integrity of the filling materials in the CLC and SC groups, whereas it had no significant effect in the WVC group. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  1. Quality of Life in Patients After Maxillectomy and Placement of Prosthetic Obturator.

    PubMed

    Chen, Cheng; Ren, Wen-Hao; Huang, Rui-Zhe; Gao, Ling; Hu, Zhi-Ping; Zhang, Lin-Mei; Li, Shao-Ming; Dong, Kai; Qi, Hong; Zhi, Ke-Qian

    2016-01-01

    The aim of this study was to assess quality of life (QoL) and obturator functioning in patients having undergone a maxillectomy as a tumor ablative resection and rehabilitation with a prosthetic obturator. The University of Washington Quality of Life scale version 4 (UW-QoLv4) and the Obturator Functioning Scale (OFS) were used to evaluate the self-reported QoL and obturator functioning. The effects of demographic and treatment variables on QoL were assessed using age, defect size, postoperative radiotherapy (RT), neck dissection, and dentition. The study included 16 men and 13 women with a mean age of 48.8 years. Of the 29 patients, 16 had a Brown Class 2a or smaller defect and 13 had a Brown Class 2b or larger defect. The mean OFS score (P = .004) and the physical (P = .001) and social-emotional function scores (P = .001) of the patients who received postoperative RT were significantly lower than those who did not receive postoperative RT. The subscales for swallowing (P = .008), saliva (P = .001), pain (P = .001), and shoulder function (P = .002) correlated strongly with postoperative RT on the UW-QoL. The subscales for pronunciation (P = .007) and saliva (P = .002) correlated significantly with RT on the OFS. The mean OFS scores were significantly lower for the patients with a Brown Class 2a or smaller defect than for Brown Class 2b or larger (P = .005). Postoperative RT was the strongest variable affecting QoL in patients with maxillectomy and prosthetic obturator reconstruction. The size of the defect slightly influenced the obturator function; however, it did not influence the overall QoL.

  2. Star Catalogs on Punched Cards and Magnetic Tape

    NASA Technical Reports Server (NTRS)

    Berbert, J. H.

    1961-01-01

    In connection with the calibration of the Minitrack satellite tracking stations, the Goddard Space Flight Center has had the contents of a number of star catalogs put on punched cards and magnetic tape. This report discusses the plate data reduction procedures, briefly describes the information on the punched cards and magnetic tape, and calls attention to other applications of the card and tape star catalogs. The Goddard Space Flight Center has offered to prepare duplicate catalogs for qualified organizations.

  3. Influence of TVT properties on outcomes of midurethral sling procedures: high-stiffness versus low-stiffness tape.

    PubMed

    Prien-Larsen, Jens Christian; Prien-Larsen, Thomas; Cieslak, Lars; Dessau, Ram B

    2016-07-01

    Although there is clear consensus on the use of monofilament polypropylene tapes for treating stress urinary incontinence (SUI), tapes differ in weight, stiffness, and elasticity. In this study, we compared outcomes of two tape types: high-stiffness Intramesh SOFT L.I.F.T versus low-stiffness Intramesh L.I.F.T. tape. Our null hypothesis was that in terms of performance, SOFT tape equaled L.I.F.T. tape. Six hundred and sixty women underwent prospective transvaginal tape (TVT) surgery for SUI: 210 had the SOFT tape placed and 450 the L.I.F.T. tape. Follow-ups were scheduled at 3 and 12 months. Objective cure at 3-months' follow-up was 87 % in the SOFT group vs 94 % in the L.I.F.T. group (p = 0.003) and at 12 months 86 vs 96 % (p = 0.0004), respectively. Subjective outcomes were equal. For SOFT tape, the objective failure rate at 3 months was especially pronounced in women older than 70 years: 31 vs 10 % (p = 0.008), and subjective failure was 24 vs 7 % (p = 0.01). At 12 months, objective failure for the SOFT tape was significantly higher in both age groups compared with L.I.F.T. [odds ratio (OR) 2.17]. Multivariate analysis showed that body mass index (BMI) ≥30 (OR 2.41), mixed incontinence (MUI) (OR 2.24), use of SOFT tape (OR 2.17), and age ≥ 70 years are significant independent risk factors for surgical failure. Outcomes with SOFT tape are significantly inferior than with L.I.F.T. tape, especially among elderly women. Therefore, the two variants of monofilament polypropylene tape are not interchangeable.

  4. Comparison of different techniques for obturating experimental internal resorptive cavities.

    PubMed

    Goldberg, F; Massone, E J; Esmoris, M; Alfie, D

    2000-06-01

    Forty extracted maxillary central incisors were instrumented at the working length to a #50 file. The roots were sectioned transversely with a diamond disk at 7 mm from the anatomical apex. At the opening of the root canal of each section, hemicircular cavities were drilled with a specially designed bur. The corresponding root sections were cemented with glue, thus obtaining root canals with similar cavities that simulated internal resorptions. Teeth were embedded in plaster casts to facilitate their handling. The specimens were randomly separated into four groups of 10. The following obturation techniques were evaluated: lateral compaction (group A), hybrid technique (group B), Obtura II (group C), and Thermafil (group D). AH26 was used as the sealer. After obturation, the plaster was removed and the teeth were radiographed in buccolingual and mesiodistal directions to evaluate the quality of the obturation at the IRC. The incisors were then cut with a scalpel at the same level as the previous section, to examine, under a stereomicroscope, the type of material that filled the IRC. Obtura II gave the best results and in most of the specimens obturated with this technique, the IRC were filled mainly with gutta-percha. Statistical analysis of the data indicated that the differences between group C and the other groups were significant (P < 0.05).

  5. In vitro resistance to fracture of roots obturated with Resilon or gutta-percha.

    PubMed

    Monteiro, Jeanne; de Ataide, Ida de Noronha; Chalakkal, Paul; Chandra, Pavan Kumar

    2011-06-01

    There have been varied results from studies comparing postendodontic fracture resistance between teeth obturated with Resilon or gutta-percha. This study was performed to evaluate the fracture resistance of roots obturated by using Resilon (RealSeal system) or gutta-percha (with AH Plus sealer). Eighty extracted human mandibular single-rooted premolars stored in 10% formalin were used in the study. They were prepared by using a crown-down technique, debrided with NaOCl, ethylenediaminetetraacetic acid, and sterile water and divided into 4 groups. Obturation was performed by using the lateral condensation method. The negative control group consisted of unfilled specimens, and the positive control group consisted of those obturated with flowable, dual-cure composite resin. All root specimens were stored for 2 weeks in 100% humidity to allow complete setting of the sealer. Each specimen was mounted in acrylic in a polyvinyl ring and tested for fracture resistance with the Universal testing machine. The loading fixture of the machine was mounted with its spherical tip aligned with the center of the canal opening of each root. A vertical loading force was applied until it fractured the root. The force values were subjected to statistical analysis including analysis of variance and Fisher least significant difference testing. Teeth obturated with Resilon were more resistant to fracture than those obturated with gutta-percha. The difference was found to be highly significant (P=.00001). Resilon increased the resistance to fracture of single-rooted teeth in vitro. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  6. The inside-out trans-obturator sling: a novel surgical technique for the treatment of male urinary incontinence.

    PubMed

    de Leval, Jean; Waltregny, David

    2008-11-01

    To describe a new sling procedure for treating stress urinary incontinence (SUI) after radical prostatectomy (RP) and prospectively evaluate its short-term safety and efficacy. The sling technique uses specific instruments and a polypropylene mesh with two arms that are passed inside to outside through the obturator foramens, pulled for compressing the bulbar urethra upward, and tied to each other across the midline. Patients with detrusor overactivity were excluded. Baseline and follow-up evaluations included uroflowmetry and continence and quality of life (QoL) questionnaires. Cure was defined by no pad use and improvement by a number of pads/d procedure using the same operative protocol. Preoperatively, 3 (15%), 11 (55%), and 6 (25%) patients were using 2, 3-5, and >5pads/d, respectively. The procedure was preceded by an endoscopic urethrotomy in four patients. No perioperative complication was noted; three patients required suprapubic catheterization. At 6 mo, nine (45%) patients were cured and eight others (40%) were improved (1pad/d). QoL was significantly enhanced and 80% of patients were moderately to completely satisfied with the procedure. Preoperative and postoperative maximum flow rate and postvoid residual values were not statistically different. No sling infection, urethra erosion, persistent pain, or neurologic complications were observed. The inside-out trans-obturator sling procedure appears to be safe and efficient at short term. Further studies are warranted to determine long-term outcome.

  7. Successful Treatment of Gluteal Pain from Obturator Internus Tendinitis and Bursitis with Ultrasound-Guided Injection.

    PubMed

    Chen, Boqing; Rispoli, Leia; Stitik, Todd; Leong, Michelle

    2017-10-01

    This case report describes what the authors believe is the first case of a patient with obturator internus tendinitis and bursitis successfully treated with a corticosteroid injection using a trans-tendinous lateral to medial approach. The patient presented with right gluteal pain not relieved by physical therapy or right hip and ischial bursa corticosteroid injections. Pelvic and lumbar spine MRIs and EMG/NCS findings were unremarkable. Physical examination demonstrated tenderness to palpation at the right middle lower gluteal region. Ultrasound imaging with sonopalpation identified the maximal local tender point as the right obturator internus muscle and/or its underlying bursa. A 22-gauge 3.5-inch needle was inserted in-plane to the transducer and longitudinal to the obturator internus from a lateral to medial direction, an approach previously described in cadavers. The obturator internus tendon sheath and bursa were injected with 2.5 ml of 0.5% lidocaine combined with 10 mg of triamcinolone. The patient reported immediate complete relief of pain with continued relief at 2 and 6 months post-injection. This case report demonstrates an injection of the obturator internus tendon sheath and bursa using a trans-tendinous approach, which may be successful for treatment of patients presenting with persistent gluteal pain from obturator internus tendinitis and bursitis.

  8. Variation of distances from mid-urethra to the obturator foramen: an MRI study

    PubMed Central

    Doumouchtsis, Stergios K.; Berger, Mitchell B.; DeLancey, John O.

    2013-01-01

    Introduction and hypothesis To estimate distances from the mid-urethra to the obturator foramina and to explore correlations between pelvic dimensions and body height. Methods This is a secondary analysis of a parent case–control study on the mechanisms of stress urinary incontinence. We measured pelvic dimensions on magnetic resonance images of women with (cases, n=50) and without (controls, n=50) stress urinary incontinence. Results The mean distance from mid-urethra to the obturator membrane among cases is 31.8 mm (left) and 32.1 mm (right), with a range from 25.9 to 42.0 mm. There were no significant differences in these distances when comparing left with right, or cases with controls. Weak correlation was found between the urethra-to-obturator foramina distances and heights only in the case subjects. Conclusion There is high variability in the distance from mid-urethra to the obturator foramina. Height should not be used as a predictor of dimensions in the lesser pelvis. PMID:22543545

  9. Procedural Due Process in Indian Education. Scripts for a Two-Part Filmstrip/Audio Tape Program. Curriculum Bulletin 18.03.

    ERIC Educational Resources Information Center

    Streiff, Paul R.

    In 1974 new sections added to the Code of Federal Regulations and the Indian Affairs Field Manual required the establishment of programs of student rights and responsibilities and due process procedures in schools operated or funded by the Bureau of Indian Affairs. This two-part filmstrip and audio tape program is designed to assist educators and…

  10. Obturator mononeuropathy caused by lipomatosis of the nerve: a case report.

    PubMed

    Nardone, Raffaele; Venturi, Alessandro; Ladurner, Gunther; Golaszewski, Stefan; Psenner, Konrad; Tezzon, Frediano

    2008-08-01

    We report a patient who presented with the clinical features of obturator mononeuropathy. Abdomino-pelvic computed tomography revealed a fusiform mass in the right perivesical space; magnetic resonance imaging (MRI) showed characteristic "coaxial-cable-like" appearance in cross-section and "spaghetti-like" appearance in longitudinal section, pathognomonic of lipomatosis of the nerve. Nerve lipomatosis as the cause of obturator neuropathy has not been previously reported. MRI provides definite and graphic proof of the diagnosis.

  11. Closed hollow bulb obturator--one-step fabrication: a clinical report.

    PubMed

    Buzayan, Muaiyed M; Ariffin, Yusnidar T; Yunus, Norsiah

    2013-10-01

    A method is described for the fabrication of a closed hollow bulb obturator prosthesis using a hard thermoforming splint material and heat-cured acrylic resin. The technique allowed the thickness of the thermoformed bulb to be optimized for weight reduction, while the autopolymerized seal area was covered in heat-cured acrylic resin, thus eliminating potential leakage and discoloration. This technique permits the obturator prosthesis to be processed to completion from the wax trial denture without additional laboratory investing, flasking, and processing. © 2013 by the American College of Prosthodontists.

  12. NASTRAN postprocessor program for transient response to input accelerations. [procedure for generating and writing modal input data on tapes using NASTRAN

    NASA Technical Reports Server (NTRS)

    Wingate, R. T.; Jones, T. C.; Stephens, M. V.

    1973-01-01

    The description of a transient analysis program for computing structural responses to input base accelerations is presented. A hybrid modal formulation is used and a procedure is demonstrated for generating and writing all modal input data on user tapes via NASTRAN. Use of several new Level 15 modules is illustrated along with a problem associated with reading the postprocessor program input from a user tape. An example application of the program is presented for the analysis of a spacecraft subjected to accelerations initiated by thrust transients. Experience with the program has indicated it to be very efficient and economical because of its simplicity and small central memory storage requirements.

  13. Are the same tapes really the same? Ultrasound study of laser-cut and mechanically cut TVT-O post-operative behavior.

    PubMed

    Rusavy, Zdenek; Masata, Jaromir; Svabik, Kamil; Hubka, Petr; Zvara, Karel; Martan, Alois

    2017-11-25

    TVT-O production has been modified to laser cutting from mechanical cutting. We compared the behavior of laser and mechanically cut tension-free vaginal tape-obturator (TVT-O) using ultrasound at various time points after surgery. This is a retrospective analysis of clinical and ultrasound data from two previously reported randomized controlled trials with TVT-O. Behavior of mechanically cut TVT-O implanted in January 2007 to November 2009 and laser-cut TVT-O implanted in May 2010 to May 2012 was assessed by ultrasound at day 1, the 2nd week, the 3rd month, and the 1st and 2nd years post-operatively. Bladder neck and tape margins positions were described by coordinates in the orthogonal system calculated from polar coordinates. Tape mobility was measured as a change in the upper and lower tape margin position from rest to maximal Valsalva. Comparison of 2-year subjective and objective surgery outcomes was also performed. In total, 68 mechanically cut and 50 laser-cut TVT-Os were implanted. Follow-up data were available from 49 and 45 women respectively. No differences in any baseline characteristics or bladder neck mobility were observed. Significantly lower tape mobility was observed on day 1 and week 2 after mechanically cut TVT-O, although subsequent mobility was comparable to laser-cut TVT-O. The subjective and objective surgery outcomes were comparable. Although without clinical significance, early postoperative behavior of the mechanically cut and laser-cut TVT-O tapes differs. The less stiff, mechanically-cut TVT-O loosens within 2 weeks of implantation, whereas the stiffer, laser-cut TVT-O keeps its tension.

  14. Surgeon-tailored polypropylene mesh as a tension-free vaginal tape-obturator versus original TVT-O for the treatment of female stress urinary incontinence: a long-term comparative study.

    PubMed

    ElSheemy, Mohammed S; Fathy, Hesham; Hussein, Hussein A; Elsergany, Ragheb; Hussein, Eman A

    2015-10-01

    The objective of the study was to compare the safety and efficacy of surgeon-tailored polypropylene mesh (STM) through tension-free vaginal tape-obturator (TVT-O) versus original TVT-O in the treatment of stress urinary incontinence (SUI) aiming to decrease the cost of treatment. This is important in developing countries due to limited health care resources. A retrospective cohort study was done at the Urology and Gynecology Departments (dual-center), Cairo University from May 2007 to June 2010. Women evaluated by cough stress test, Stress and Urge Incontinence and Quality of Life Questionnaire (SUIQQ), maximum flow rate (Qmax), and abdominal leak point pressure (ALPP) with follow-up for at least 48 months were included. Patients with post-void residual urine > 100 ml, bladder capacity < 300 ml, or impaired compliance were excluded. The effect of different factors on outcome was compared between both groups pre- and postoperatively using the paired t, Wilcoxon signed rank, McNemar, chi-square, Fisher's exact, independent t, or Mann-Whitney tests. STM and TVT-O were inserted in 79 and 66 women, respectively. Intrinsic sphincter deficiency, ALPP, previous surgeries, associated urgency, urgency urinary incontinence (UUI), and prolapse were comparable in both groups. Operative duration was longer in STM by 10 min. No significant difference was found between both groups in complications (p = 0.462), cure (p = 0.654), and different indices of SUIQQ. In STM, 74 (93 %) were cured and 3 (4 %) improved, while SUI persisted in 2 (2 %) patients. In TVT-O, 59 (89 %) were cured and 4 (6 %) improved, while failure was detected in 3 (4 %) patients. The 5-year outcome is comparable between STM and TVT-O. Furthermore, STM is more economical due to our resterilizable modified helical passers and the cheap polypropylene mesh.

  15. Gemelli-obturator complex in the deep gluteal space: an anatomic and dynamic study.

    PubMed

    Balius, Ramon; Susín, Antonio; Morros, Carles; Pujol, Montse; Pérez-Cuenca, Dolores; Sala-Blanch, Xavier

    2018-06-01

    To investigate the behavior of the sciatic nerve during hip rotation at subgluteal space. Sonographic examination (high-resolution ultrasound machine at 5.0-14 MHZ) of the gemelli-obturator internus complex following two approaches: (1) a study on cadavers and (2) a study on healthy volunteers. The cadavers were examined in pronation, pelvis-fixed position by forcing internal and external rotations of the hip with the knee in 90° flexion. Healthy volunteers were examined during passive internal and external hip rotation (prone position; lumbar and pelvic regions fixed). Subjects with a history of major trauma, surgery or pathologies affecting the examined regions were excluded. The analysis included eight hemipelvis from six fresh cadavers and 31 healthy volunteers. The anatomical study revealed the presence of connective tissue attaching the sciatic nerve to the structures of the gemellus-obturator system at deep subgluteal space. The amplitude of the nerve curvature during rotating position was significantly greater than during resting position. During passive internal rotation, the sciatic nerve of both cadavers and healthy volunteers transformed from a straight structure to a curved structure tethered at two points as the tendon of the obturator internus contracted downwards. Conversely, external hip rotation caused the nerve to relax. Anatomically, the sciatic nerve is closely related to the gemelli-obturator internus complex. This relationship results in a reproducible dynamic behavior of the sciatic nerve during passive hip rotation, which may contribute to explain the pathological mechanisms of the obturator internal gemellus syndrome.

  16. Endodontic flare-ups: comparison of incidence between single and multiple visits procedures in patients attending a Nigerian teaching hospital.

    PubMed

    Oginni, Ao; Udoye, C I

    2004-12-01

    The present study was performed to compare the incidence of endodontic flare ups in single with multiple visits treatment procedures, to establish the relationship between pre-operative and post obturation pain in patients attending for endodontic therapy in a Nigerian teaching Hospital. Patients were randomly assigned to either single visit or multiple visits group. Data collected at root canal treatment appointment and recall visits (1st, 7th and 30th day post obturation) include pulp vitality status, the presence or absence of pre-operative pain, presence and degree of post obturation pain. Presence of endodontic flare-ups (defined as either patient's report of pain not controlled with over the counter medication and or increasing swelling). The compiled data were analyzed using chi-square where applicable. P level < 0.05 was taken as significant. Ten endodontic flare-ups (8.1 %) were recorded in the multiple visits group compared to 19 (18,3%) flare-ups for the single visit group, P = 0.02. For both single and multiple visits procedures, there were statistically significant correlations between pre operative and post obturation pain (P = 0.002 and P = 0.0004 respectively). Teeth with vital pulps reported the lowest frequency of post obturation pain (48.8%), while those with non vital pulps were found to have the highest frequency oh post obturation pain (50,3%), P = 0.9. Although the present study reported higher incidences for post obturation pain and flare-ups following the single visit procedures, single visit endodontic therapy has been shown to be a safe and effective alternative to multiple visits treatment.

  17. [Clinical-diagnostic estimation of carbohydrates metabolism in obturation jaundice].

    PubMed

    Nychytaĭlo, M Iu; Malyk, S V

    2004-07-01

    Complex examination of 175 patients with obturation jaundice was conducted, peculiar attention was spared to the carbohydrates metabolism changes, characterizing hepatic state. It was established, that in obturation jaundice in the liver there are occurring inflammatory changes and disturbances of all kinds of metabolism, including that of carbohydrates, severity of which depends on duration of jaundice, the concurrent diseases presence, they shows lowering of the glucose and glycogen level in the blood, as well as the hepatic glycogen content, that's why they may be applied as a complex of prognostic criterions for the disease course. An early conduction of operative treatment, elimination of the biliary ducts impassability promote the rehabilitation period shortening and the hepatic functional activity normalization.

  18. A simplified technique of orthograde MTA obturation on the elected canals of posterior teeth: Two case reports.

    PubMed

    Wahengbam, Brucelee; Wahengbam, Pragya; Tikku, Aseem Prakash

    2014-01-01

    This article suggests a simplified technique of orthograde MTA obturation in less accessible canal(s) of posteriors teeth without using costly ultrasonics or specialised carrier. Essentially few finger pluggers, absorbent points and a simple canal projection method were used. The orifice(s) of the elected canal(s) to be obturated with MTA were projected onto the external occlusal surface for easy delivery and predictive instrumentation. The idea was based on 'easy access', 'working one canal with one mix at one time', 'thorough condensation' and 'removal of excess moisture'. In case I, palatal canal of tooth no. 2 with gross apical perforation and suspected VRF was obturated with MTA. And in Case II, tooth no. 19 presented with incomplete furcal fracture extending into the canal was obturated with MTA in all 3 canals unitarily. Dense homogenous MTA obturation was achieved and both cases healed uneventfully.

  19. Endodontic flare-ups: comparison of incidence between single and multiple visit procedures in patients attending a Nigerian teaching hospital.

    PubMed

    Oginni, Adeleke O; Udoye, Christopher I

    2004-11-26

    BACKGROUND: Until recently the most accepted technique of doing root canal treatment stresses multiple visit procedure. Most schools also concentrated upon teaching the multi-visit concept. However, it has now been reported that the procedure of single visit treatment is advocated by at least 70% of schools in all geographical areas. It was therefore the aims of the present study to find the incidence of post-obturation flare-ups following single and multiple visit endodontic treatment procedures, and to establish the relationship between pre-operative and post-obturation pain in patients referred for endodontic therapy in a Nigerian teaching Hospital. METHODS: Data collected included pulp vitality status, the presence or absence of pre-operative, inter-appointment and post-obturation pain. Pain was recorded as none, slight, or moderate/severe. Flare-ups were defined as either patient's report of pain not controlled with over the counter medication or as increasing swelling. The patients were recalled at three specific post-obturation periods, 1st, 7th and 30th day. The presence or absence of pain, or the appropriate degree of pain was recorded for each recall visits and the interval between visits. The compiled data were analysed using chi-square where applicable. P level procedures, there were statistically significant correlations between pre-operative and post-obturation pain (P = 0.002 and P = 0.0004 respectively). Teeth with vital pulps reported the lowest frequency of post-obturation pain (48.8%), while those with nonvital pulps were found to have the highest frequency of post-obturation pain (50.3%), P = 0.9. CONCLUSION: The present study reported higher incidences of post-obturation pain and flare-ups following the single visit

  20. Evaluation of a New Thermoplastic Gutta Percha Obturation Technique Using 45Ca.

    DTIC Science & Technology

    1980-10-27

    Codes A,’lzi 1 and/or D 1 Spoe 0, ’ -mi ll .. ., , N .... i I .. hl i Ii n . .. . .. INTRODUCTION In the development of endodontic therapy, many types...of filling material have been used for obturation.1-3 Various techniques of obturation have also been employed. In present day endodontic therapy, the...primary objectives of endodontic therapy.3 ,6𔄁 Various radioisotopes have been utilized to evaluate the adequacy of the apical seal. 8-13 One

  1. Revision anatomical reconstruction of the lateral ligaments of the ankle augmented with suture tape for patients with a failed Broström procedure.

    PubMed

    Cho, B K; Kim, Y M; Choi, S M; Park, H W; SooHoo, N F

    2017-09-01

    The aim of this prospective study was to evaluate the intermediate-term outcomes after revision anatomical ankle ligament reconstruction augmented with suture tape for a failed modified Broström procedure. A total of 30 patients with persistent instability of the ankle after a Broström procedure underwent revision augmented with suture tape. Of these, 24 patients who were followed up for more than two years were included in the study. There were 13 men and 11 women. Their mean age was 31.8 years (23 to 44). The mean follow-up was 38.5 months (24 to 56) The clinical outcome was assessed using the Foot and Ankle Outcome Score (FAOS) and the Foot and Ankle Ability Measure (FAAM) score. The stability of the ankle was assessed using stress radiographs. The mean FAOS and FAAM scores improved significantly to 87.5 (73 to 94) and 85.1 (70 to 95) points at final follow-up, respectively (p < 0.001). The mean angle of talar tilt and anterior talar translation improved significantly to 2.8° (0° to 6°) and 4.1 mm (2 to 7) at final follow-up, respectively (p < 0.001). Side to side comparison in stress radiographs at final follow-up showed no significant difference. The revision failed in one patient who underwent a further revision using allograft tendon. The revision modified Broström procedure augmented with suture tape is an effective form of treatment for recurrent instability of the ankle following a failed Broström procedure. This technique provides reliable stability and satisfactory clinical outcomes at intermediate-term follow-up. Cite this article: Bone Joint J 2017;99-B:1183-9. ©2017 The British Editorial Society of Bone & Joint Surgery.

  2. Comparative evaluation of three obturation techniques in primary incisors using digital intra-oral receptor and C.B.C.T-an in vitro study.

    PubMed

    Akhil, Jose E J; Prashant, Babaji; Shashibushan, K K

    2018-05-10

    Successful pulpectomy in primary teeth depends on quality of obturation. It can be evaluated using digital intra-oral receptor (D.I.O.R) and cone beam computed tomography (C.B.C.T). The purposes of this study were to compare 3 different obturation techniques such as lentulospiral, insulin syringe, and endodontic plugger in primary incisors and to evaluate its quality of obturation using D.I.O.R and C.B.C.T technique. Thirty-three extracted primary incisors were biomechanically prepared and obturated with zinc oxide eugenol cement by 3 different obturation techniques. The obturation was evaluated for length of obturation and voids using D.I.O.R and C.B.C.T methods. There was a statistically significant difference between all the groups in length of obturation (P = 0.02) in both D.I.O.R and C.B.C.T. Significant differences (P = 0.03) were present in number of voids among 3 obturation techniques in C.B.C.T. Statistically more voids were observed with D.I.O.R in lentulospiral (P = 0.04) group and in insulin syringe (P = 0.02) group. Acceptable result was obtained with lentulospiral in length of obturation compared to insulin syringe and endodontic plugger technique. Insulin syringe technique resulted in increased underfilling with least number of voids. More number of voids were seen in middle one-third and least number of voids were observed at apical one third of the root among all the 3 techniques of obturation. The study concluded that void identification is improved with D.I.O.R compared to C.B.C.T. Lentulospiral reported effective length of obturation, while insulin syringe with least number of voids. D.I.O.R (2-Dimensional) is efficient in detecting voids compared to C.B.C.T (3-Dimensional) in obturated primary teeth.

  3. Microgap Evaluation of Novel Hydrophilic and Hydrophobic Obturating System: A Scanning Electron Microscope Study.

    PubMed

    Hegde, Vibha; Murkey, Laxmi Suresh

    2017-05-01

    The purpose of an endodontic obturation is to obtain a fluid tight hermetic seal of the entire root canal system. There has been an evolution of different materials and techniques to achieve this desired gap free fluid tight seal due to presence of anatomic complexity of the root canal system. To compare the microgap occurring in root canals obturated with hydrophilic versus hydrophobic systems using scanning electron microscope. Sixty extracted human single-rooted premolars were decoronated, instrumented using NiTi rotary instruments. The samples (n=20) were divided into three groups and obturated with Group A - (control group) gutta-percha with AH Plus, Group B - C-point with Smartpaste Bio and Group C - gutta-percha with guttaflow 2. The samples were split longitudinally into two halves and microgap was observed under scanning electron microscope in the apical 3 mm of the root canal. Group A (control) showed a mean difference of 8.54 as compared to 5.76 in group C. Group B showed the lowest mean difference of 0.83 suggesting that the hydrophilic system (C-point/Smartpaste Bio) produced least microgap as compared to the hydrophobic groups. Novel hydrophilic obturating system (C-points/ Smart-paste Bio) showed better seal and least microgap as compared to gutta-percha/guttaflow 2 and gutta-percha/ AH plus which showed gap at the sealer dentin interface due to less penetration and bonding of these hydrophobic obturating system.

  4. Effect of 95% Ethanol as a Final Irrigant before Root Canal Obturation in Primary Teeth: An in vitro Study.

    PubMed

    Thiruvenkadam, G; Asokan, Sharath; John, Baby; Priya, Pr Geetha

    2016-01-01

    Successful obturation in the primary teeth demands complete dryness of the root canal system. The purpose of this study was to determine the effect of 95% ethanol as the final irrigant before root canal obturation in primary teeth. A total of 20 extracted primary mandibular canines were biomechanically prepared and pre-obturated volume of each tooth was assessed using spiral computed tomography (CT). The specimens were divided into two groups (n = 10): group 1, Metapex group; group 2, zinc oxide eugenol group. Each group was further divided randomly into two subgroups (n = 5): subgroup 1, canals were dried with 95% ethanol; subgroup 2, canals were blot dried with paper points with the last one appearing dry. All canals were obturated and the postobturated volume of each tooth was measured. The percentage of obturated volume (POV) was calculated using the formula: (postobturated volume/preobturated volume) × 100. The POV between the groups was statistically analyzed using Mann-Whitney test and Wilcoxon Signed rank test appropriately. Root canals that were dried with ethanol showed better obturation than using paper points alone and the difference was statistically significant in both group 1 (p < 0.001) and group 2 (p < 0.002). Drying of the root canal system with 95% ethanol can result in better obturation in the primary teeth. How to cite this article: Thiruvenkadam G, Asokan S, John B, Geetha Priya PR. Effect of 95% Ethanol as a Final Irrigant before Root Canal Obturation in Primary Teeth: An in vitro Study. Int J Clin Pediatr Dent 2016;9(1):21-24.

  5. Comparative evaluation of endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe in obturation of primary teeth: An in vitro study.

    PubMed

    Hiremath, Mallayya C; Srivastava, Pooja

    2016-01-01

    The purpose of this in vitro study was to compare four methods of root canal obturation in primary teeth using conventional radiography. A total of 96 root canals of primary molars were prepared and obturated with zinc oxide eugenol. Obturation methods compared were endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe. The root canal obturations were evaluated by conventional radiography for the length of obturation and presence of voids. The obtained data were analyzed using Chi-square test. The results showed significant differences between the four groups for the length of obturation (P < 0.05). The endodontic pressure syringe showed the best results (98.5% optimal fillings) and jiffy tube showed the poor results (37.5% optimal fillings) for the length of obturation. The insulin syringe (79.2% optimal fillings) and local anesthetic syringe (66.7% optimal fillings) showed acceptable results for the length of root canal obturation. However, minor voids were present in all the four techniques used. Endodontic pressure syringe produced the best results in terms of length of obturation and controlling paste extrusion from the apical foramen. However, insulin syringe and local anesthetic syringe can be used as effective alternative methods.

  6. TVT-Secur (Hammock) Versus TVT-Obturator: A Randomized Trial of Suburethral Sling Operative Procedures

    PubMed Central

    Hota, Lekha S.; Hanaway, Katherine; Hacker, Michele R.; Disciullo, Anthony; Elkadry, Eman; Dramitinos, Patricia; Shapiro, Alexander; Ferzandi, Tanaz; Rosenblatt, Peter L.

    2013-01-01

    Objectives This study aimed to compare TVT-Secur (TVT-S) and TVT-Obturator (TVT-O) suburethral slings for treatment of stress urinary incontinence (SUI). Methods This was a single-center, nonblinded, randomized trial of women with SUI who were randomized to TVT-S or TVT-O from May 2007 to April 2009. The primary outcome, SUI on cough stress test (CST), and quality-of-life and symptom questionnaires (Pelvic Floor Distress Inventory [PFDI-20] and Pelvic Floor Impact Questionnaire [PFIQ-7]) were assessed at 12 weeks and 1 year. Results Forty-three women were randomized to TVT-S and 44 to TVT-O. There were no differences in median baseline PFDI-20 and PFIQ-7. Twenty-two (52.4%) of 42 participants randomized to TVT-S had a positive CST result at evaluation after 12 weeks or 1 year, whereas 4 (9.1%) of the 44 in the TVT-O group had a positive CST result. The intent-to-treat analysis showed that the risk of a positive CST result was 6 times higher after TVT-S than TVT-O (risk ratio, 6.0; 95% confidence interval [CI], 2.3–16.0). Among women not lost to follow-up, the risk ratio for a positive CST result after TVT-S compared with TVT-O was 17.9 (95% CI, 2.5–128.0) at 12 weeks and 3.5 (95% CI, 1.1–11.0) at 1 year. Both TVT-S and TVT-O resulted in improved quality of life and symptoms at 12 weeks. There was no difference between the groups for PFDI-20 (P = 0.40) or PFIQ-7 (P = 0.43). A similar pattern was seen at 1 year (P = 0.85 and P = 0.36). Conclusions The TVT-S seems to have a higher risk of positive postoperative CST result; however, the procedures result in similar improvements in quality of life and symptoms. PMID:22453267

  7. TVT-Secur (Hammock) versus TVT-Obturator: a randomized trial of suburethral sling operative procedures.

    PubMed

    Hota, Lekha S; Hanaway, Katherine; Hacker, Michele R; Disciullo, Anthony; Elkadry, Eman; Dramitinos, Patricia; Shapiro, Alexander; Ferzandi, Tanaz; Rosenblatt, Peter L

    2012-01-01

    This study aimed to compare TVT-Secur (TVT-S) and TVT-Obturator (TVT-O) suburethral slings for treatment of stress urinary incontinence (SUI). This was a single-center, nonblinded, randomized trial of women with SUI who were randomized to TVT-S or TVT-O from May 2007 to April 2009. The primary outcome, SUI on cough stress test (CST), and quality-of-life and symptom questionnaires (Pelvic Floor Distress Inventory [PFDI-20] and Pelvic Floor Impact Questionnaire [PFIQ-7]) were assessed at 12 weeks and 1 year. Forty-three women were randomized to TVT-S and 44 to TVT-O. There were no differences in median baseline PFDI-20 and PFIQ-7. Twenty-two (52.4%) of 42 participants randomized to TVT-S had a positive CST result at evaluation after 12 weeks or 1 year, whereas 4 (9.1%) of the 44 in the TVT-O group had a positive CST result. The intent-to-treat analysis showed that the risk of a positive CST result was 6 times higher after TVT-S than TVT-O (risk ratio, 6.0; 95% confidence interval [CI], 2.3-16.0). Among women not lost to follow-up, the risk ratio for a positive CST result after TVT-S compared with TVT-O was 17.9 (95% CI, 2.5-128.0) at 12 weeks and 3.5 (95% CI, 1.1-11.0) at 1 year. Both TVT-S and TVT-O resulted in improved quality of life and symptoms at 12 weeks. There was no difference between the groups for PFDI-20 (P = 0.40) or PFIQ-7 (P = 0.43). A similar pattern was seen at 1 year (P = 0.85 and P = 0.36). The TVT-S seems to have a higher risk of positive postoperative CST result; however, the procedures result in similar improvements in quality of life and symptoms.

  8. Effects of different root canal obturation techniques on bacterial penetration.

    PubMed

    Yücel, Ali Cağin; Ciftçi, Alper

    2006-10-01

    The aim of this study was to compare bacterial penetration following obturation with 5 different techniques. This study was performed on 120 teeth including negative control (n = 10), positive control (n = 10), and experimental groups (n = 100). One hundred teeth were randomly divided into 5 groups of 20 teeth each and obturated with System B (Sb), Lateral Compaction (Lc), Thermafil (T), Single ProTaper Gutta-percha (P), and laterally compacted ProTaper Gutta-percha (PLc). Enterococcus faecalis was used for determination of the bacterial penetration. Evaluation was carried out for 60 days. At 30 days, the chi2 test showed that the slowest penetration was observed in Group Sb and Group PLc, which were not significantly different from each other. The fastest penetration in the all experimental groups was observed in Group T and Group P, which were not significantly different from one another. Also, there was no statistically significance difference (P > .05) among all groups at 60 days. It may be concluded that under the conditions of this study System B and laterally compacted ProTaper Gutta-percha prevent bacterial penetration of the root canal at 30 days. Furthermore, there was no difference among obturation techniques at 60 days.

  9. An In-Vitro Evaluation and Comparison of Apical Sealing Ability of Three Different Obturation Technique - Lateral Condensation, Obtura II, and Thermafil.

    PubMed

    Emmanuel, Samson; Shantaram, Kulkarni; Sushil, Kumar C; Manoj, Likhitkar

    2013-04-01

    Success of non-surgical root canal treatment is predicted by meticulous cleaning and shaping of the root canal system, three-dimensional obturation and a well-fitting "leakage-free" coronal restoration. The techniques of obturation that are available have their own relative position in the historical development of filling techniques. Over the years, pitfalls with one technique have often led to the development of newer methods of obturation, along with the recognition that no one method of obturation may satisfy all clinical cases. A total of 120 extracted human permanent anterior maxillary and mandibular single rooted teeth were selected for the present study and divided into 3 groups based on the method of obturation technique. Following the preparation the patency at the apical foramen was confirmed by passing a file #15. After obturation of all three groups, teeth were immersed in 1% of aqueous methylene blue dye for a period of two weeks and then samples were subjected to spectrophotometric analysis. The present study was conducted to evaluate in vitro the spectrophotometric analysis to quantitatively analyze relative amount of dye penetration using lateral condensation (Group I), Obtura II (Group II ), Thermafil obturating technique (Group III) with ZOE sealer used in all groups. Teeth obturated with lateral condensation (Group I) shows mean value of 0.0243 and standard deviation of 0.0056. The Group II thermoplasticized injectable moulded Guttapercha (Obtura II) showed 0.0239 mean and standard deviation value of 0.0045 and Group III Thermafil obturation technique shows 0.0189 as mean value and 0.0035 standard deviation values. Following conclusion was drawn from the present study. Group III i.e., Thermafil obturating technique shows minimum mean apical dye penetration compared to Group II (ObturaII) and Group I (lateral condensation).Lateral condensation shows maximum mean apical dye penetration in all three groups.There is no significant difference between

  10. Tape transport mechanism

    DOEpatents

    Groh, Edward F.; McDowell, William; Modjeski, Norbert S.; Keefe, Donald J.; Groer, Peter

    1979-01-01

    A device is provided for transporting, in a stepwise manner, tape between a feed reel and takeup reel. An indexer moves across the normal path of the tape displacing it while the tape on the takeup reel side of the indexer is braked. After displacement, the takeup reel takes up the displaced tape while the tape on the feed reel side of the indexer is braked, providing stepwise tape transport in precise intervals determined by the amount of displacement caused by the indexer.

  11. A comparative In vivo efficacy of three spiral techniques versus incremental technique in obturating primary teeth.

    PubMed

    Chandrasekhar, Shalini; Prasad, Madu Ghanashyam; Radhakrishna, Ambati Naga; Saujanya, Kaniti; Raviteja, N V K; Deepthi, B; Ramakrishna, J

    2018-01-01

    The aim of this study was to evaluate the efficiency of four different obturating techniques in filling the radicular space in primary teeth. This clinical trial was carried out on 34 healthy, cooperative children (5-9 years) who had 63 carious primary teeth indicated for pulpectomy. They were divided into four groups, such that in each group, a total of 40 canals were allotted for obturation with respective technique. The root canals of selected primary teeth were filled with Endoflas obturating material using either bi-directional spiral (Group 1); incremental technique (Group 2), past inject (Group 3) or lentulo spiral (Group 4) according to the groups assigned. The effectiveness of the obturation techniques was assessed using postoperative radiographs. The assessment was made for a depth of fill in the canal, the presence of any voids using Modified Coll and Sadrian criteria. The obtained data were analyzed by using ANOVA test and unpaired t-test. Bi-directional spiral and lentulo spiral were superior to other techniques in providing optimally filled canals (P< 0.05). The bi-directional spiral was superior to lentulo spiral in preventing overfill (P< 0.05). Based on the present study results, bi-directional spiral can be recommended as an alternate obturating technique in primary teeth.

  12. A quantitative and qualitative analysis of ultrasonic versus sonic endodontic systems on canal cleanliness and obturation.

    PubMed

    Kanter, Valerie; Weldon, Emily; Nair, Uma; Varella, Claudio; Kanter, Keith; Anusavice, Kenneth; Pileggi, Roberta

    2011-12-01

    The purpose of this study was to compare 2 irrigation techniques by evaluating canal cleanliness and obturation of lateral/accessory canals. Seventy-five extracted canines were instrumented to a size #40/0.06 taper. The EndoActivator (EA) was compared with an ultrasonic unit for final irrigation. Each unit was used for 1 minute each with 6.15% NaOCl and 17% EDTA. A control group received syringe irrigation. Thirty teeth were sectioned and evaluated for debris removal and open dentinal tubules at 3/5 mm from the apical foramen with a scanning electron microscope. Forty-five teeth were examined for obturation of lateral canals. The EA was significantly better in removing debris at all levels when compared with other treatment groups (P < .05) and resulted in obturation of significantly more numbers of lateral canals (P < .01.) The EA provided better obturation of lateral and accessory canals and resulted in less remaining debris. Copyright © 2011 Mosby, Inc. All rights reserved.

  13. Tape tracking and handling for magnetic tape recorders. [aboard spacecraft

    NASA Technical Reports Server (NTRS)

    Paroby, W.; Disilvestre, R.

    1975-01-01

    One of the critical performance and life limiting elements of a spacecraft tape recorder instrumentation system which has received little attention in technical literature is magnetic tape tracking and handling technology. This technology is required to understand how to gently transfer tape from one reel to another with proper alignment and a desirable uniform velocity at the read and write transducer heads. The increased demand for high data rate (i.e., multi-track spacecraft recording instrumentation systems), coupled with performance under extreme environmental conditions, requires a thorough knowledge of the various parameters which establish an optimum designed tape tracking and handling system. Stress analysis techniques are required to evaluate these parameters substantiated with test tape tracking data, to show the effect of each parameter on a tape recorder instrumentation tracking system. The technology is applicable to ground type tape recorders where the detrimental effects of edge guidance can be eliminated.

  14. Five year magnetic tape for unattended satellite tape recorders

    NASA Technical Reports Server (NTRS)

    Benn, G. S. L.; Gutfreund, K.

    1972-01-01

    The development and fabrication of a quantity of long life magnetic tape with properties selected specifically for unattended operation in spacecraft tape recorders was studied. A detailed analytical consideration of various binder systems was undertaken. This included the chemical aspects of the binders, cohesion and adhesion effects, stability and the mechanical and physical properties. The ability to form free films of these polymers and their combination with various oxide loadings and other additives allowed a rapid selection of four polymer candidates for a five year magnetic tape. Samples were evaluated under actual running conditions which included physical, magnetic, and extensive life testing. These sample tapes withstood 50,000 bidirectional tape passes under fairly harsh operating conditions.

  15. An Experimental Investigation of Damaged Arresting Gear Tapes for the Langley Aircraft Landing Dynamics Facility

    NASA Technical Reports Server (NTRS)

    Mason, Angela J.

    1999-01-01

    An experimental investigation was performed on damaged arresting gear tapes at the Langley Aircraft Landing Dynamics Facility. The arrestment system uses five pairs of tapes to bring the test carriage to a halt. The procedure used to determine when to replace the tapes consists of a close evaluation of each of the 10 tapes after each run. During this evaluation, each tape is examined thoroughly and any damage observed on the tape is recorded. If the damaged tape does not pass the inspection, the tape is replaced with a new one. For the past 13 years, the most commonly seen damage types are edge fray damage and transverse damage. Tests were conducted to determine the maximum tensile strength of a damaged arresting gear tape specimen. The data indicate that tapes exhibiting transverse damage can withstand higher loads than tapes with edge fray damage.

  16. Effects of sociodemographic, treatment variables, and medical characteristics on quality of life of patients with maxillectomy restored with obturator prostheses.

    PubMed

    Artopoulou, Ioli Ioanna; Karademas, Evangelos C; Papadogeorgakis, Nikolaos; Papathanasiou, Ioannis; Polyzois, Gregory

    2017-12-01

    Restoration of maxillary defects resulting from tumor ablative surgery presents a difficult challenge, with both functional and esthetic issues. Whether rehabilitation with an obturator prosthesis could significantly contribute to improved quality of life in patients with maxillary resection has been scarcely studied, with relatively small study samples. The purpose of this survey study was to assess the overall functioning of the obturator prosthesis and the effect of specific sociodemographic, medical, and treatment variables on obturator functioning and quality of life in patients with maxillectomy. Global quality of life (QOL) and satisfaction with the obturator prosthesis of 57 patients who underwent maxillectomy and prosthetic rehabilitation at the National and Kapodistrian University of Athens were assessed using 3 questionnaires: European Organization for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire C30 (QLQ-C30), the EORTC QLQ-HN35, and the obturator functioning scale. The data were analyzed using the Kruskal-Wallis 1-way ANOVA on ranks, hierarchical multiple regression analysis, and the Spearman rank order correlation (α=.05). Satisfactory functioning of the obturator prosthesis was the most significant predictor of improved QOL (P<.05). QOL was significantly related to additional treatments (P<.05), the size of the primary tumor (P<.05), and the size of the maxillectomy defect (P<.05). The most significant predictors of good obturator functioning were additional treatments (P<.01), age at the time of surgery (P<.05), presence of mandibular teeth (P<.05), and previous maxillary removable prosthetic experience (P<.05). Obturator functioning scale appearance and insertion subscales (r=0.47, P<.01), followed by speech (r=0.42, P<.01), were significantly related to better QOL. A well-functioning obturator prosthesis was the most significant determinant for improved QOL in patients with maxillary resection. Age at the time of surgery

  17. Tape Placement Head for Applying Thermoplastic Tape to an Object

    NASA Technical Reports Server (NTRS)

    Cope, Ralph D. (Inventor); Funck, Steve B. (Inventor); Gruber, Mark B. (Inventor); Lamontia, Mark A. (Inventor); Johnson, Anthony D. (Inventor)

    2008-01-01

    A tape placement head for applying thermoplastic tape to an object includes a heated feeder which guides the tape/tow to a heated zone. The heated zone has a line compactor having a single row of at least one movable heated member. An area compactor is located in the heated zone downstream from the line compactor. The area compactor includes a plurality of rows of movable feet which are extendable toward the tape/tow different distances with respect to each other to conform to the shape of the object. A shim is located between the heated compactors and the tape/tow. A chilled compactor is in a chilled zone downstream from the heated zone. The chilled zone includes a line chilled compactor and an area chilled compactor. A chilled shim is mounted between the chilled compactor and the tape/tow.

  18. Influence of root canal instrumentation and obturation techniques on intra-operative pain during endodontic therapy

    PubMed Central

    Martín-González, Jenifer; Echevarría-Pérez, Marta; Sánchez-Domínguez, Benito; Tarilonte-Delgado, Maria L.; Castellanos-Cosano, Lizett; López-Frías, Francisco J.

    2012-01-01

    Objective: To analyse the influence of root canal instrumentation and obturation techniques on intra-operative pain experienced by patients during endodontic therapy. Method and Materials: A descriptive cross-sectional study was carried out in Ponferrada and Sevilla, Spain, including 80 patients (46 men and 34 women), with ages ranged from 10 to 74 years, randomly recruited. Patient gender and age, affected tooth, pulpal diagnosis, periapical status, previous NSAID or antibiotic (AB) treatment, and root canal instrumentation and obturation techniques were recorded. After root canal treatment (RCT), patients completed a 10-cm visual analogue scale (VAS) that ranked the level of pain. Results were analysed statistically using the Chi-square and ANOVA tests and logistic regression analysis. Results: The mean pain level during root canal treatment was 2.9 ± 3.0 (median = 2) in a VAS between 0 and 10. Forty percent of patients experienced no pain. Gender, age, arch, previous NSAIDs or AB treatment and anaesthetic type did not influence significantly the pain level (p > 0.05). Pain during root canal treatment was significantly greater in molar teeth (OR = 10.1; 95% C.I. = 1.6 - 63.5; p = 0.013). Root canal instrumentation and obturation techniques did not affect significantly patient’s pain during root canal treatment (p > 0.05). Conclusion: Patients feel more pain when RCT is carried out on molar teeth. The root canal instrumentation and obturation techniques do not affect significantly the patients’ pain during RCT. Key words:Anaesthesia, endodontic pain, pulpitis, root canal instrumentation, root canal obturation, rotary files. PMID:22549694

  19. Tape functionality: sonographic tape characteristics and outcome after TVT incontinence surgery.

    PubMed

    Kociszewski, Jacek; Rautenberg, Oliver; Perucchini, Daniele; Eberhard, Jakob; Geissbühler, Verena; Hilgers, Reinhard; Viereck, Volker

    2008-01-01

    To investigate tension-free vaginal tape (TVT) position and shape using ultrasound (US) and correlate the findings to outcome. The results of TVT surgery were investigated in 72 women with urodynamic stress urinary incontinence. The main outcome parameters were US tape position in relation to the urethra and dynamic changes in TVT shape at rest and during straining. Sixty-two patients (86%) were continent, 6 (8%) significantly improved, and the operation failed in four cases (6%). The median tape position was at 66% of the urethral length measured by US. The median tape-urethra-lumen distance was 3.8 mm at rest. Tape placement in the upper or lower quarter of the urethra was associated with a higher failure rate. Tapes positioned less than 3 mm from the urethra significantly increased postoperative complications (P < 0.0001). The tape was flat at rest and curved during straining in 44 (61%) patients; 98% (43/44) of these women were continent after surgery. An unchanged tape shape was associated with a poorer outcome (P = 0.00038). Patients with a flat tape at rest and during straining failed in 25% and patients with a permanent curved shape in 10%. TVT position relative to the patient's urethra seems to play a role in treatment outcome. Outcome was best in patients with dynamic change in tape shape during straining and location of the tape at the junction between the lower and middle urethra and at least 3 mm from the urethral lumen. (c) 2008 Wiley-Liss, Inc.

  20. Combined ultrasound and fluoroscopic guidance for radiofrequency ablation of the obturator nerve for intractable cancer-associated hip pain.

    PubMed

    Stone, Jonathan; Matchett, Gerald

    2014-01-01

    Management of pain from skeletal metastases is notoriously difficult. Case reports and case series have described radiofrequency ablation of the obturator nerve branches to the femoral head for treatment of intractable hip pain. Ablation of the obturator branches to the femoral head is technically difficult because of bony and vascular anatomy, including close proximity of the femoral vessels. Here we present the case of a 79-year-old woman with intractable right hip pain and inability to ambulate secondary to metastatic non-small cell lung cancer in the femoral head and acetabulum, treated with thermal radiofrequency ablation of the obturator and femoral nerve branches to the femoral head. Ablation of the obturator nerve was done via anterior placement of the radiofrequency needle under combined ultrasound and fluoroscopic guidance, passing the radiofrequency needle between the femoral artery and femoral vein. Real-time ultrasound guidance was used to avoid vascular puncture. Thermal radiofrequency ablation resulted in sustained pain relief, and resumption in the ability of the patient to ambulate. From this case we suggest that an anterior approach to the obturator nerve branches to the femoral head may be technically feasible using combined ultrasound and fluoroscopic guidance to avoid vascular puncture.

  1. Efficacy of ProTaper Retreatment System in Root Canals Obturated with Gutta-Percha Using Two Different Sealers and GuttaFlow

    PubMed Central

    Siotia, Jaya; Acharya, Shashi Rashmi; Gupta, Sunil Kumar

    2011-01-01

    Objective. To compare the efficacy of ProTaper retreatment files in removing three different obturating materials. Study Design. Forty-five human, single-rooted premolars were divided into three experimental groups. Group 1 was obturated with gutta-percha and AH Plus sealer, Group 2 was obturated with gutta-percha and zinc oxide eugenol sealer, and Group 3 was obturated with GuttaFlow. Retreatment was done using the ProTaper universal rotary retreatment files. Root halves were visualized using magnifying loops at 3X magnification and optical stereomicroscope at 10X magnification. Images were analyzed using AutoCAD 2004 software to calculate area of the remaining debris in the canal. For statistical analysis were used variance test and ANOVA. Results. Total debris/canal area ratio between the three groups showed a statistically significant difference (P < 0.001). Conclusion. ProTaper retreatment system did not produce completely clean canals in any of the groups. However, it had the best efficacy towards removing silicon based obturating material GuttaFlow. PMID:22114598

  2. Primary obturator externus pyomyositis in a child presenting as hip pain: a case report.

    PubMed

    Kumar, Abhishek; Anderson, David

    2008-02-01

    Hip pain in children often poses a diagnostic dilemma. Septic arthritis, Perthes disease, and slipped capital femoral epiphysis are among the most important causes. Pyomyositis involving muscles around the hip can present with similar features as septic arthritis and are difficult to diagnose because of their rarity and indolent presentation. Obturator internus and iliopsoas muscle abscess have been most commonly reported, with only 1 such report on isolated obturator externus muscle abscess. Routine laboratory investigations are nonspecific, and the diagnosis rests on imaging modalities. Magnetic resonance scan is the most useful investigation in the diagnosis and can pick up early changes in the muscle. Treatment involves appropriate antibiotic therapy with or without drainage. Most cases resolve completely. We report here a case of isolated obturator externus muscle abscess in an 11-year-old child illustrating the similarities with septic arthritis of hip and problems encountered during diagnosis and management.

  3. A Comparison of Class-Wide Taped Problems and Cover, Copy, and Compare for Enhancing Mathematics Fluency

    ERIC Educational Resources Information Center

    Poncy, Brian C.; Skinner, Christopher H.; McCallum, Elizabeth

    2012-01-01

    An adapted alternating treatments design was used to compare the effects of class-wide applications of Taped Problems (TP) and Cover, Copy, and Compare (CCC) procedures designed to enhance subtraction fact fluency in an intact third-grade classroom. During the TP procedure, a tape provided an auditory prompt (i.e., the problem), followed by a…

  4. Effects of two different knee tape procedures on lower-limb kinematics and kinetics in recreational runners.

    PubMed

    Howe, A; Campbell, A; Ng, L; Hall, T; Hopper, D

    2015-08-01

    The purpose of this study was to compare the effects of Mulligan's tape (MT) and kinesio tape (KT) with no tape (NT) on hip and knee kinematics and kinetics during running. Twenty-nine female recreational runners performed a series of 'run-throughs' along a 10-m runway under the three taping conditions. Two force plates and a 14-camera Vicon motion analysis system (Oxford Metrics, Inc., Oxford, UK) captured kinematic and kinetic data for each dependent variable from ground contact to toe off. Comparisons of each dependent variable under three taping conditions were assessed through Statistical Package for the Social Sciences (SPSS; SPSS, Inc., Chicago, Illinois, USA; P-value < 0.01) using repeated measure analyses of variance. For each dependent variable with a P-value < 0.01, repeated measures with pairwise comparisons and Bonferroni adjustment were conducted to compare the three taping conditions. MT induced a significant reduction in anterior and posterior hip forces, knee flexion angular velocity, knee extensor moments, and hip flexion and extension moments compared with NT and KT (P = 0.001). There was no difference in hip or knee, kinematics or kinetics, between KT and NT (P = 1.000). MT appears to influence hip and knee biomechanics during running in an asymptomatic sample, whereas KT appeared to be biomechanically not different from NT. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. The obturator oblique and iliac oblique/outlet views predict most accurately the adequate position of an anterior column acetabular screw.

    PubMed

    Guimarães, João Antonio Matheus; Martin, Murphy P; da Silva, Flávio Ribeiro; Duarte, Maria Eugenia Leite; Cavalcanti, Amanda Dos Santos; Machado, Jamila Alessandra Perini; Mauffrey, Cyril; Rojas, David

    2018-06-08

    Percutaneous fixation of the acetabulum is a treatment option for select acetabular fractures. Intra-operative fluoroscopy is required, and despite various described imaging strategies, it is debatable as to which combination of fluoroscopic views provides the most accurate and reliable assessment of screw position. Using five synthetic pelvic models, an experimental setup was created in which the anterior acetabular columns were instrumented with screws in five distinct trajectories. Five fluoroscopic images were obtained of each model (Pelvic Inlet, Obturator Oblique, Iliac Oblique, Obturator Oblique/Outlet, and Iliac Oblique/Outlet). The images were presented to 32 pelvic and acetabular orthopaedic surgeons, who were asked to draw two conclusions regarding screw position: (1) whether the screw was intra-articular and (2) whether the screw was intraosseous in its distal course through the bony corridor. In the assessment of screw position relative to the hip joint, accuracy of surgeon's response ranged from 52% (iliac oblique/outlet) to 88% (obturator oblique), with surgeon confidence in the interpretation ranging from 60% (pelvic inlet) to 93% (obturator oblique) (P < 0.0001). In the assessment of intraosseous position of the screw, accuracy of surgeon's response ranged from 40% (obturator oblique/outlet) to 79% (iliac oblique/outlet), with surgeon confidence in the interpretation ranging from 66% (iliac oblique) to 88% (pelvic inlet) (P < 0.0001). The obturator oblique and obturator oblique/outlet views afforded the most accurate and reliable assessment of penetration into the hip joint, and intraosseous position of the screw was most accurately assessed with pelvic inlet and iliac oblique/outlet views. Clinical Question.

  6. Comparing the diagnostic properties of skin scraping, adhesive tape, and dermoscopy in diagnosing scabies.

    PubMed

    Abdel-Latif, Azmy A; Elshahed, Ahmad R; Salama, Omar A; Elsaie, Mohamed L

    2018-06-01

    Scabies is a contagious skin infestation that mainly presents with itching at night and skin burrows that are visible to the naked eye. Diagnosing scabies with dermoscopy is still a matter of controversy. The aim of our study was to compare the diagnostic properties of adhesive tape, skin scraping, and dermoscopy in diagnosing scabies. One hundred patients with clinical presumptive diagnoses of scabies underwent skin scraping, adhesive tape testing, and dermoscopic examination. Each diagnostic procedure was performed on three different areas. Comparing the diagnostic properties of the three methods, the adhesive tape test was the most sensitive method for diagnosing scabies. Sixteen cases (16.0%) were definitely diagnosed as scabies using the adhesive tape test detecting the presence of mites or their eggs. Only 10 cases (10.0%) were definitely diagnosed as scabies using the skin scraping test detecting mites or their eggs. Dermoscopic examination suggested a diagnosis of scabies in 22 cases (22.0%), of which only 10 were definitely diagnosed as scabies by detecting mites using the adhesive tape test, skin scraping, or both. The diagnosis of scabies can only be confirmed by seeing mites. The adhesive tape test and skin scraping procedure have high specificity in diagnosing scabies, but their low sensitivity cannot exclude the possibility of scabies. Dermoscopy-guided tape testing can be a helpful tool for better diagnosis of scabies.

  7. Post-Obturation pain following one-visit and two-visit root canal treatment in necrotic anterior teeth.

    PubMed

    Rao, K Nandan; Kandaswamy, Raghavendra; Umashetty, Girish; Rathore, Vishnu Pratap Singh; Hotkar, Chetan; Patil, Basanagouda S

    2014-04-01

    To investigate and compare the post-obturation pain after one-visit and two-visit root canal treatment in non-vital anterior teeth. One hundred forty eight patients requiring root canal therapy on permanent anterior non-vital teeth with single root were included in this study. Patients were randomly assigned to either the one-appointment or the twoappointment group. The standardized protocol for all the teeth involved local anesthesia, isolation and access, engine-driven rotary nickel-titanium canal instrumentation with 2.5% NaOCl irrigation and obturation. Teeth in group 1 (n = 74) were obturated during the first appointment by using laterally condensed gutta-percha and resin sealer. Teeth in group 2 (n = 74) were given closed dressing and were obturated during the second appointment, 7 to 14 days later. A modified Visual Analogue Scale was used to measure pain after 6 hours, 24 hours, 48 hours and 7 days after the treatment. Statistical analysis was done to compare groups at each interval by using an independent-samples t test. The incidence and intensity of post-obturation pain in both Group 'A' and Group 'B' gradually reduced over the study period. When the incidence of pain was compared in the single and two visit group, it was found that the single-visit group experienced slightly less pain than the two-visit group during all study intervals, but the difference found was not statistically significant. There was no difference in postoperative pain between patients treated in only one appointment and patients treated in two appointments. The majority of patients in both groups reported no pain or only minimal pain after 7 days of treatment. How to cite the article: Rao KN, Kandaswamy R, Umashetty G, Rathore VP, Hotkar C, Patil BS. Post-Obturation pain following one-visit and two-visit root canal treatment in necrotic anterior teeth. J Int Oral Health 2014;6(2):28-32.

  8. [Rehabilitation by hollow obturator prosthesis immediately after total maxillectomy for malignant tumor].

    PubMed

    Li, Xiao-ye; Yan, Ai-hui; Hao, Shuai; Li, Wei; Jiang, Xue-jun; Lu, Li; Qin, Xing-jun; Yan, Hai-xin

    2011-05-01

    The feasibility and clinical effects of hollow obturator prosthesis for the repair of maxillofacial defect immediately after maxillectomy for cancer were assessed. Thirteen patients with T3-4aN0M0 maxillary neoplasm were treated by the prostheses immediately after maxillectomy. According to the 3D-CT reconstruction of nasal sinus, the 3D stereoscopic prototype was constructed before the surgery. Simulating surgery with Surgicare 5.0 software and then the prosthesis 3D stereoscopic model was shaped. The prosthesis was made quickly and precisely with methacrylate resins according to the model and the print mold before surgery, with supplementary tooth at the bottom of prosthesis. In the surgery, the prosthesis was installed instantly after maxillectomy. The patients were followed up at 1, 3 and 6 month after the surgery, respectively. The facial features and the pronunciation clarity were examined and the questionnaires were carried out in the patients, with comparation by paired t-test. The hollow obturator prosthesis would be replaced by permanent prosthesis made of methacrylate resins at 6 month after the surgery. The hollow obturator prostheses were installed accurately and maxillofacial defects were repaired immediately after maxillectomy in the 13 patients. Postoperative follow-up showed there were significant differences in eyeball sagging (t = 4.67, P < 0.05), mid-facial region collapse (t = 5.67, P < 0.05), and pronunciation clarity (t = 16.38, P < 0.05) between patients with and without prostheses. Questionnaires showed that all the patients were satisfied with the retention of prostheses, the improvement of appearance, the improvement of the symptom of water choking and speech definition. Six months after the surgery, the hollow obturator prostheses were replaced smoothly by permanent prostheses in 11 of the 13 patients. The precise and instant repair of maxillofacial defect by prosthesis after maxillectomy can improve survival quality of patient.

  9. Management of maxillectomy defect with a hybrid hollow bulb obturator

    PubMed Central

    Singh, Kamleshwar; Singh, Saumyendra V; Mishra, Niraj; Agrawal, Kaushal Kishor

    2013-01-01

    A woman having already undergone maxillectomy came to the department complaining of difficulty in eating and speech. During the construction of an obturator, the bulb area should be hollowed to reduce weight so that the teeth and supporting tissues are not stressed unnecessarily. The conventional open design drains fluid from the adjacent mucosa, possibly increasing the weight of the prosthesis, and is difficult to clean. The closed bulb design does not drain secretions and may cause obstruction and susceptibility to infection in the paranasal and pharyngeal regions, though it is easier to maintain. An alternative to the two designs, combining their advantages, is presented in this report. As the open hollow part of the obturator was shallow, it was easy to clean. Making the inferior part of the bulb hollow and closed led to a reduction in the overall weight of the prosthesis while increasing its resonance. PMID:23436886

  10. Applying extrusive orthodontic force without compromising the obturated canal space.

    PubMed

    Keinan, David; Szwec, Jerard; Matas, Avital; Moshonov, Joshua; Yitschaky, Oded

    2013-08-01

    Complicated tooth fractures can be the unfortunate result of orofacial trauma and can offer a therapeutic challenge for the dentist. A conservative solution for gaining supragingival sound tooth structure often includes orthodontic forced eruption. Usually, this procedure is carried out by applying extrusive force after placing a provisional acrylic Richmond crown on the tooth. However, this long-lasting dental treatment may jeopardize the coronal seal of the root canal space, leading to microleakage and endodontic failure. Orthodontic forced eruption demands application of force to an attachment connected to the remaining short clinical crown. In this article, the authors describe a case in which they used a new technique for orthodontic forced eruption of a traumatized tooth, using an extracanal attachment to apply extrusion force, and discuss its possible advantages and limitations. An extracanal attachment approach for orthodontic forced eruption without compromising the obturated canal space can be a solution for posttraumatic crown fracture. Practical Implications. The described procedure for forced eruption by using an extracanal pin attachment is efficient and convenient and does not require the clinician to apply force directly to the provisional crown. Therefore, during the application of force, there is less risk of loosening the provisional crown, and the canal space is kept intact with either the final restoration or dressing material.

  11. [Laryngeal Tube Position Shift after Chest Compression: Comparison of Fixation Methods Using Durapore Tape, Multipore Tape, or a Neck Tape].

    PubMed

    Seno, Hisayo; Komasawa, Nobuyasu; Fujiwara, Shunsuke; Miyazaki, Shinichiro; Tatsumi, Shinichi; Minami, Toshiaki

    2015-05-01

    The laryngeal tube (LT ; Smiths Medical, Minnesota, U. S. A) is an inflatable supraglottic device for emergency airway management such as during chest compression, the instability after insertion remains a problem. We investigated the effectiveness of three fixation methods of LT using a manikin and automated chest compressor. After 10-minute chest compression, LT without fixation was shifted by 0.4 ± 0.1 cm, which was greater than with Durapore tape (0.2 ± 0.1 cm), Multipore tape (0.2 ± 0.1 cm), or a neck tape (0.1 ± 0.1 cm). The shift of the position was smaller with neck tape fixation compared to Durapore or Multipore tape fixation. A fixation neck tape may be useful in stabilizing the inserted position of LT during cardiopulmonary resuscitation.

  12. Tape reading fixture

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Commercially available roller type desk pad provides an efficient and orderly manner of handling rolled paper tapes for proofreading. The fixture, which is modified to accept Flex-O-Writer or similar tapes and roll them in either direction, reduces the chance of damaging or soiling the tapes through repeated handling.

  13. Thermoplastic tape compaction device

    DOEpatents

    Campbell, V.W.

    1994-12-27

    A device is disclosed for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite. 5 figures.

  14. Thermoplastic tape compaction device

    DOEpatents

    Campbell, Vincent W.

    1994-01-01

    A device for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite.

  15. Pollen tube access to the ovule is mediated by glycoprotein secretion on the obturator of apple (Malus × domestica, Borkh)

    PubMed Central

    Herrero, Maria

    2017-01-01

    Background and Aims Within the ovary, the obturator bridges the pathway of the pollen tube from the style to the ovule. Despite its widespread presence among flowering plants, its function has only been studied in a handful of species, and the molecules involved in pollen tube–obturator cross-talk have not been explored hitherto. This work evaluates the involvement of glucans and glycoproteins on pollen tube growth in the obturator of apple flowers (Malus × domestica). Methods Pollen tube kinetics were sequentially examined in the pistil and related to changes occurring on the obturator using histochemistry and inmunocytochemistry. To discriminate between changes in the obturator induced by pollen tubes from those developmentally regulated, both pollinated and unpollinated pistils were examined. Key Results Pollen tube growth rates were slow in the stigma, faster in the style and slow again in the ovary. The arrival of pollen tubes at the obturator was concomitant with the secretion of proteins, saccharides and glycoprotein epitopes belonging to extensins and arabinogalactan proteins (AGPs). While some of these secretions – extensins and AGPs labelled by JIM13 – were developmentally regulated, others – AGPs labelled by JIM8 – were elicited by the presence of pollen tubes. Following pollen tube passage, all these glycoproteins were depleted. Conclusions The results show a timely secretion of glycoproteins on the obturator surface concomitant with pollen tube arrival at this structure. The fact that their secretion is depleted following pollen tube passage strongly suggests their role in regulating pollen tube access to the ovule. Remarkably, both the regulation of the secretion of the different glycoproteins, as well as their association with the performance of pollen tubes exhibit similarities with those observed in the stigma, in line with their common developmental origin. PMID:28137704

  16. Pollen tube access to the ovule is mediated by glycoprotein secretion on the obturator of apple (Malus × domestica, Borkh).

    PubMed

    Losada, Juan M; Herrero, Maria

    2017-04-01

    Within the ovary, the obturator bridges the pathway of the pollen tube from the style to the ovule. Despite its widespread presence among flowering plants, its function has only been studied in a handful of species, and the molecules involved in pollen tube-obturator cross-talk have not been explored hitherto. This work evaluates the involvement of glucans and glycoproteins on pollen tube growth in the obturator of apple flowers ( Malus × domestica) . Pollen tube kinetics were sequentially examined in the pistil and related to changes occurring on the obturator using histochemistry and inmunocytochemistry. To discriminate between changes in the obturator induced by pollen tubes from those developmentally regulated, both pollinated and unpollinated pistils were examined. Pollen tube growth rates were slow in the stigma, faster in the style and slow again in the ovary. The arrival of pollen tubes at the obturator was concomitant with the secretion of proteins, saccharides and glycoprotein epitopes belonging to extensins and arabinogalactan proteins (AGPs). While some of these secretions - extensins and AGPs labelled by JIM13 - were developmentally regulated, others - AGPs labelled by JIM8 - were elicited by the presence of pollen tubes. Following pollen tube passage, all these glycoproteins were depleted. The results show a timely secretion of glycoproteins on the obturator surface concomitant with pollen tube arrival at this structure. The fact that their secretion is depleted following pollen tube passage strongly suggests their role in regulating pollen tube access to the ovule. Remarkably, both the regulation of the secretion of the different glycoproteins, as well as their association with the performance of pollen tubes exhibit similarities with those observed in the stigma, in line with their common developmental origin. © The Author 2017. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions

  17. Clinical and radiographic evaluation of zinc oxide with aloe vera as an obturating material in pulpectomy: an in vivo study.

    PubMed

    Khairwa, Abhishek; Bhat, Manohar; Sharma, Rajesh; Satish, V; Maganur, Prabhadevi; Goyal, Anil Kumar

    2014-01-01

    Pulp therapy for pulpally involved primary teeth continues to be a challenge to clinicians. One of the major areas of continued research is in the area of finding obturating materials to suit the specific properties of these teeth. Zinc oxide eugenol is used frequently in pulpectomy for the obturation of the primary teeth. To evaluate clinically and radiographically a mixture of zinc oxide eugenol and aloe vera as an obturating material. A total of 50 children, aged between 4 and 9 years, who were screened for unilateral or bilateral carious deciduous molars were studied. Out of these, 15 children were randomly selected for endodontic treatment. Obturation was done with a mixture of zinc oxide powder and aloe vera gel. Clinical and radiographic evaluation was done after 7 days, 1 month, 3 months, 6 months, and 9 months. The data were statistically analyzed. Endodontic treatment using a mixture of zinc oxide powder and aloe vera gel in primary teeth has shown good clinical and radiographic success. A detailed observational study with longer follow-up will highlight the benefits of aloe vera in primary teeth as an obturating medium.

  18. Thermoplastic tape compaction device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, V.W.

    1994-12-27

    A device is disclosed for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin bandmore » of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite. 5 figures.« less

  19. PHOTOELECTRIC CONTROL FOR TAPE POSITIONING

    DOEpatents

    Woody, J.W. Jr.

    1961-07-25

    A control system is described for producing control impulses which may be used to start, stop, and position a magnetic tape with respect to a transducer, and to locate discrete areas on the tape. Means are provided for positive identification of data blocks, exact positioning of the tape under the magnetic head, drive in either direction, accurate skip-over of imperfect regions of the tape, stopping the tape if equipment malfunction results in a failure to detect the block-identifying signals, and starting and stopping those parts of the tape between of the tape drive clutches.

  20. User's guide for the Nimbus 7 ERB Solar Analysis Tape (ESAT)

    NASA Technical Reports Server (NTRS)

    Hickey, J. R.; Major, E. R.; Kyle, H. L.

    1984-01-01

    Five years of Nimbus 7 ERB solar data is available in compact form on a single ERB solar analysis tape (ESAT). The period covered is November 16, 1978 through October 31, 1983. The Nimbus 7 satellite performs just under 14 orbits a day and the ERB solar telescope observe the Sun once per orbit as the satellite passes + or - near the south pole. The data were carefully calibrated and screened. Mean orbital and daily values are given for the total solar irradiance plus selected spectral intervals. In addition, selected solar activity indicators are on the tape. The ERB experiment, the solar data calibration and screening procedures, the solar activity indicators, and the tape format are described briefly.

  1. The Carbon Monoxide Tape Recorder

    NASA Technical Reports Server (NTRS)

    Schoeberl, M. R.; Duncan, B. N.; Douglass, A. R.; Waters, J.; Livesey, N.; Read, W.; Filipiak, M.

    2006-01-01

    Using Aura MLS data we have identified the stratospheric tape recorder in carbon monoxide (CO). Unlike the water vapor tape recorder, which is controlled by upper troposphere processes, the CO tape recorder is linked to seasonal biomass burning. Since CO has a lifetime of only a few months, the CO tape recorder barely extends above 20 km. The tape head for CO appears to be close to 360K near the same location as the water vapor tape head [Read et al, 20041. Both tape heads are below the equatorial cold point tropopause but above the base of the tropical tropopause layer. The tape recorder signal becomes more distinct from 360K to 380K suggesting that convective detrainment of plays a decreasingly important role with altitude. The Global Modeling Initiative chemical transport model forced by the climatology of biomass burning reproduces the CO tape recorder.

  2. Fabricating a tooth- and implant-supported maxillary obturator for a patient after maxillectomy with computer-guided surgery and CAD/CAM technology: A clinical report.

    PubMed

    Noh, Kwantae; Pae, Ahran; Lee, Jung-Woo; Kwon, Yong-Dae

    2016-05-01

    An obturator prosthesis with insufficient retention and support may be improved with implant placement. However, implant surgery in patients after maxillary tumor resection can be complicated because of limited visibility and anatomic complexity. Therefore, computer-guided surgery can be advantageous even for experienced surgeons. In this clinical report, the use of computer-guided surgery is described for implant placement using a bone-supported surgical template for a patient with maxillary defects. The prosthetic procedure was facilitated and simplified by using computer-aided design/computer-aided manufacture (CAD/CAM) technology. Oral function and phonetics were restored using a tooth- and implant-supported obturator prosthesis. No clinical symptoms and no radiographic signs of significant bone loss around the implants were found at a 3-year follow-up. The treatment approach presented here can be a viable option for patients with insufficient remaining zygomatic bone after a hemimaxillectomy. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. Pulsed radiofrequency treatment of articular branches of femoral and obturator nerves for chronic hip pain.

    PubMed

    Chye, Cien-Leong; Liang, Cheng-Loong; Lu, Kang; Chen, Ya-Wen; Liliang, Po-Chou

    2015-01-01

    Chronic hip pain is a common symptom experienced by many people. Often, surgery is not an option for patients with multiple comorbidities, and conventional drugs either have many side effects or are ineffective. Pulsed radiofrequency (PRF) is a new method in the treatment of pain. We attempt to compare the efficacy of PRF relative to conservative management for chronic hip pain. Between August 2011 and July 2013, 29 patients with chronic hip pain were divided into two groups (PRF and conservative treatment) according to consent or refusal to undergo PRF procedure. Fifteen patients received PRF of the articular branches of the femoral and obturator nerves, and 14 patients received conservative treatment. Visual analog scale (VAS), Oxford hip scores (OHS), and pain medications were used for outcome measurement before treatment and at 1 week, 4 weeks, and 12 weeks after treatment. At 1 week, 4 weeks, and 12 weeks after treatment initiation, improvements in VAS were significantly greater with PRF. Improvements in OHS were significantly greater in the PRF group at 1 week, 4 weeks, and 12 weeks. Patients in the PRF group also used less pain medications. Eight subjects in the conservative treatment group switched to the PRF group after 12 weeks, and six of them had >50% improvement. When compared with conservative treatment, PRF of the articular branches of the femoral and obturator nerves offers greater pain relief for chronic hip pain and can augment physical functioning.

  4. Superconducting properties of multilayered Ag/Bi(Pb)-2223 tapes prepared using pretextured monolayered tapes

    NASA Astrophysics Data System (ADS)

    Syamaprasad, U.; Sarma, M. S.; Guruswamy, P.; Pillai, S. G. K.; Warrier, K. G. K.; Damodaran, A. D.

    1997-02-01

    Multilayered Ag/Bi(Pb)-2223 tapes with high critical current densities 0953-2048/10/2/005/img1 have been fabricated using partially heat treated, textured monolayered tapes. Cut sections of the monolayered tapes have been stacked one over the other and folded together using high-purity silver foil and further rolled and heat treated to obtain multilayered tapes of different thickness with an HTS layer thickness varying from 9 to 0953-2048/10/2/005/img2. A comparison of the superconducting properties of the multilayered tapes with those of monolayered tapes prepared under identical heat treatment conditions shows that the 0953-2048/10/2/005/img3 ratio at 77 K is as high as 0.57. The ratio is found to decrease with a decrease in the HTS core thickness of the multilayered tapes. XRD studies of `banana peeled' samples show that the monolayered tapes at the folding stage acquire a good degree of texturing. The relatively high value of the 0953-2048/10/2/005/img3 ratio obtained in the present case compared with those reported by the existing techniques is attributed to the use of pretextured monolayered tapes.

  5. Magnetic tape user guide

    NASA Technical Reports Server (NTRS)

    Evans, A. B.; Lee, L. L.

    1985-01-01

    This User Guide provides a general introduction to the structure, use, and handling of magnetic tapes at Langley Research Center (LaRC). The topics covered are tape terminology, physical characteristics, error prevention and detection, and creating, using, and maintaining tapes. Supplementary documentation is referenced where it might be helpful. The documentation is included for the tape utility programs, BLOCK, UNBLOCK, and TAPEDMP, which are available at the Central Scientific Computing Complex at LaRC.

  6. Effect of different intraorifice barriers on the fracture resistance of roots obturated with Resilon or gutta-percha.

    PubMed

    Nagas, Emre; Uyanik, Ozgur; Altundasar, Emre; Durmaz, Veli; Cehreli, Zafer C; Vallittu, Pekka K; Lassila, Lippo V J

    2010-06-01

    This study investigated and compared the root reinforcement potential of 3 different intraorifice barriers (mineral trioxide aggregate [MTA], resin-modified glass ionomer cement [Vitremer], and fiber-reinforced composite [FRC]) placed over root canals obturated with gutta-percha or Resilon. Crowns of 80 extracted human mandibular premolars were sectioned off to obtain 14-mm-long root specimens. After preparation of root canals with nickel-titanium rotary files, the roots were obturated with either the Resilon/Epiphany system or gutta-percha + AH Plus sealer. In both obturation groups, specimens were further subgrouped with respect to the intraorifice barrier material placed after removal of 3-mm coronal portion of the root fillings: (1) MTA, (2) Vitremer, and (3) FRC. The specimens were loaded vertically at 1 mm/min crosshead speed until vertical root fracture occurred. Results were evaluated statistically with two-way analysis of variance and Tukey tests. Fracture resistance of roots was significantly affected by the type of intraorifice barrier (P < .05), but not by the type of obturation system used (P > .05). The use of Vitremer and FRC significantly improved the fracture resistance, whereas MTA did not exhibit any reinforcing effect as an intraorifice barrier. Copyright 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. Ability of New Obturation Materials to Improve the Seal of the Root Canal System – A Review

    PubMed Central

    Zhang, Wei; Olsen, Mark; De-Deus, Gustavo; Eid, Ashraf A.; Chen, Ji-hua; Pashley, David H.; Tay, Franklin R.

    2014-01-01

    Objectives New obturation biomaterials have been introduced over the past decade to improve the seal of the root canal system. However, it is not clear whether they have really produced a three-dimensional impervious seal that is important for reducing diseases associated with root canal treatment. Methods A review of the literature was performed to identify models that have been employed for evaluating the seal of the root canal system. Results and Significance In-vitro and in-vivo models are not totally adept at quantifying the seal of root canals obturated with classic materials. Thus, one has to resort to clinical outcomes to examine whether there are real benefits associated with the use of recently-introduced materials for obturating root canals. However, there is no facile answer because endodontic treatment outcomes are influenced by a host of other predictors that are more likely to take precedence over the influence of obturation materials. From the perspective of clinical performance, classic root filling materials have stood the test of time. Because many of the recently-introduced materials are so new, there is not enough evidence yet to support their ability to improve clinical performance. This emphasizes the need to translate anecdotal information into clinically relevant research data on new biomaterials. PMID:24321349

  8. Effectiveness of spinal anesthesia combined with obturator nerve blockade in preventing adductor muscle contraction during transurethral resection of bladder tumor

    PubMed Central

    Alavi, Cyrus Emir; Asgari, Seyed Alaeddin; Falahatkar, Siavash; Rimaz, Siamak; Naghipour, Mohammadreza; Khoshrang, Hossein; Jafari, Mehdi; Herfeh, Nadia

    2017-01-01

    Objective To determine whether spinal anesthesia combined with obturator nerve blockade (SOB) is effective in preventing obturator nerve stimulation, jerking and bladder perforation during transurethral resection of bladder tumor (TURBT). Material and methods In this clinical trial, 30 patients were randomly divided into two groups: spinal anesthesia (SA) and SOB. In SA group, 2.5 cc of 0.5% bupivacaine was injected intrathecally using a 25-gauge spinal needle and in SOB after spinal anesthesia, a classic obturator nerve blockade was performed by using nerve stimulation technique. Results There was a statistically significant difference between jerking in both groups (p=0.006). During the TURBT, surgeon satisfaction was significantly higher in SOB group compared to SA group (p=0.006). There was no significant correlation between sex, patient age and location of bladder tumor between the groups (p>0.05). Conclusion Obturator nerve blockade by using 15 cc lidocaine 1% is effective in preventing adductor muscle spasms during TURBT. PMID:29201516

  9. Uniform GTD solution for the diffraction by metallic tapes on panelled compact-range reflectors

    NASA Technical Reports Server (NTRS)

    Somers, G. A.; Pathak, P. H.

    1992-01-01

    Metallic tape is commonly used to cover the interpanel gaps which occur in paneled compact-range reflectors. It is therefore of interest to study the effect of the scattering by the tape on the field in the target zone of the range. An analytical solution is presented for the target zone fields scattered by 2D metallic tapes. It is formulated by the generalized scattering matrix technique in conjunction with the Wiener-Hopf procedure. An extension to treat 3D tapes can be accomplished using the 2D solution via the equivalent current concept. The analytical solution is compared with a reference moment method solution to confirm the accuracy of the former.

  10. Interpretation of the human skin biotribological behaviour after tape stripping.

    PubMed

    Pailler-Mattei, C; Guerret-Piécourt, C; Zahouani, H; Nicoli, S

    2011-07-06

    The present study deals with the modification of the human skin biotribological behaviour after tape stripping. The tape-stripping procedure consists in the sequential application and removal of adhesive tapes on the skin surface in order to remove stratum corneum (SC) layers, which electrically charges the skin surface. The skin electric charges generated by tape stripping highly change the skin friction behaviour by increasing the adhesion component of the skin friction coefficient. It has been proposed to rewrite the friction adhesion component as the sum of two terms: the first classical adhesion term depending on the intrinsic shear strength, τ(0), and the second term depending on the electric shear strength, τ(elec). The experimental results allowed to estimate a numerical value of the electric shear strength τ(elec). Moreover, a plan capacitor model with a dielectric material inside was used to modelize the experimental system. This physical model permitted to evaluate the friction electric force and the electric shear strength values to calculate the skin friction coefficient after the tape stripping. The comparison between the experimental and the theoretical value of the skin friction coefficient after the tape stripping has shown the importance of the electric charges on skin biotribological behaviour. The static electric charges produced by tape stripping on the skin surface are probably able to highly modify the interaction of formulations with the skin surface and their spreading properties. This phenomenon, generally overlooked, should be taken into consideration as it could be involved in alteration of drug absorption.

  11. Interpretation of the human skin biotribological behaviour after tape stripping

    PubMed Central

    Pailler-Mattei, C.; Guerret-Piécourt, C.; Zahouani, H.; Nicoli, S.

    2011-01-01

    The present study deals with the modification of the human skin biotribological behaviour after tape stripping. The tape-stripping procedure consists in the sequential application and removal of adhesive tapes on the skin surface in order to remove stratum corneum (SC) layers, which electrically charges the skin surface. The skin electric charges generated by tape stripping highly change the skin friction behaviour by increasing the adhesion component of the skin friction coefficient. It has been proposed to rewrite the friction adhesion component as the sum of two terms: the first classical adhesion term depending on the intrinsic shear strength, τ0, and the second term depending on the electric shear strength, τelec. The experimental results allowed to estimate a numerical value of the electric shear strength τelec. Moreover, a plan capacitor model with a dielectric material inside was used to modelize the experimental system. This physical model permitted to evaluate the friction electric force and the electric shear strength values to calculate the skin friction coefficient after the tape stripping. The comparison between the experimental and the theoretical value of the skin friction coefficient after the tape stripping has shown the importance of the electric charges on skin biotribological behaviour. The static electric charges produced by tape stripping on the skin surface are probably able to highly modify the interaction of formulations with the skin surface and their spreading properties. This phenomenon, generally overlooked, should be taken into consideration as it could be involved in alteration of drug absorption. PMID:21227961

  12. Finite element analysis of maxillary bone stress caused by Aramany Class IV obturator prostheses.

    PubMed

    Miyashita, Elcio Ricardo; Mattos, Beatriz Silva Câmara; Noritomi, Pedro Yoshito; Navarro, Hamilton

    2012-05-01

    The retention of an Aramany Class IV removable partial dental prosthesis can be compromised by a lack of support. The biomechanics of this obturator prosthesis result in an unusual stress distribution on the residual maxillary bone. This study evaluated the biomechanics of an Aramany Class IV obturator prosthesis with finite element analysis and a digital 3-dimensional (3-D) model developed from a computed tomography scan; bone stress was evaluated according to the load placed on the prosthesis. A 3-D model of an Aramany Class IV maxillary resection and prosthesis was constructed. This model was used to develop a finite element mesh. A 120 N load was applied to the occlusal and incisal platforms corresponding to the prosthetic teeth. Qualitative analysis was based on the scale of maximum principal stress; values obtained through quantitative analysis were expressed in MPa. Under posterior load, tensile and compressive stresses were observed; the tensile stress was greater than the compressive stress, regardless of the bone region, and the greatest compressive stress was observed on the anterior palate near the midline. Under an anterior load, tensile stress was observed in all of the evaluated bone regions; the tensile stress was greater than the compressive stress, regardless of the bone region. The Aramany Class IV obturator prosthesis tended to rotate toward the surgical resection when subjected to posterior or anterior loads. The amount of tensile and compressive stress caused by the Aramany Class IV obturator prosthesis did not exceed the physiological limits of the maxillary bone tissue. (J Prosthet Dent 2012;107:336-342). Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  13. Three tumor patients with total maxillectomy rehabilitated with implant-supported frameworks and maxillary obturators: a follow-up report.

    PubMed

    Örtorp, Anders

    2010-12-01

    Few reports are available on treatment using implant-supported frameworks with maxillary obturators after total maxillectomy on tumor patients. To describe, evaluate, and report the clinical and radiographic performance of implant-supported frameworks and maxillary obturators after maxillectomy during the first years of function. Three patients with cancer in the maxillary region treated by total maxillectomy were rehabilitated. Seventeen dental and two craniofacial implants were installed, and the patients each received implant-supported, screw-retained, three-unit frameworks with a U-shaped bar and obturators retained by four magnetic attachments. Clinical and radiographic data were collected up to 7 years of follow-up. The frequency of complications was low. Two craniofacial implants and one dental implant were loose and removed at abutment connection. No implants were lost after framework connection, and the mean marginal bone loss was small. Within the limitations of this report, dental implants are useful for rehabilitation of total maxillectomy patients, and a three-unit, screw-retained, implant-supported framework with maxillary obturator retained by magnetic attachment is a successful treatment concept for this patient group. © 2009, Copyright the Author. Journal Compilation © 2010, Wiley Periodicals, Inc.

  14. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 3 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 6 and 7. The activities from other flight days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). Flight day 6 features a very complicated EVA (extravehicular activity) to service the HST (Hubble Space Telescope). Astronauts Grunsfeld and Linnehan replace the HST's power control unit, disconnecting and reconnecting 36 tiny connectors. The procedure includes the HST's first ever power down. The cleanup of spilled water from the coollant system in Grunsfeld's suit is shown. The pistol grip tool, and two other space tools are also shown. On flight day 7, Newman and Massimino conduct an EVA. They replace the HST's FOC (Faint Object Camera) with the ACS (Advanced Camera for Surveys). The video ends with crew members playing in the shuttle's cabin with a model of the HST.

  15. Tape/head interface study

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Existing high energy tapes, high track density heads, and transport guidance techniques were evaluated and characterized to enable these technologies to be employed in future spacecraft recorders with high confidence. The results of these study efforts demonstrated tracking accuracy tape and head density that will support spacecraft recorders with data rates of a minimum of 150 Mbps and storage capacities ranging from 10 to the 10th to 10 to the 11th bits. Seven high energy tapes of either .25 in width, 1.00 in width, or both, were tested. All tapes were tested at the same speed (30 ips) and the same packing density (33 KBI). The performance of all 1 in tapes was considered superior.

  16. Music for the Eyes: Slide/Tape and Video Techniques.

    ERIC Educational Resources Information Center

    Pembrook, Randall G.

    1983-01-01

    Slide/tape and videotape presentations can be used in music education to project music scores, document music tours and special programs, and present self-contained units for student mastery of specific skills. Materials needed, cost, and procedures for teacher-developed materials are outlined. (KC)

  17. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  18. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  19. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  20. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  1. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  2. Case Presentation of Two Maxillectomy Patients Restored with Two-piece Hollow Bulb Obturator Retained using Two Different Types of Magnets.

    PubMed

    Parameswari, B Devi; Rajakumar, M; Jagadesaan, N; Annapoorni, H

    2017-11-01

    Palatal defect can be repaired by reconstructive surgery and/or a dental prosthesis. We present prosthodontic rehabilitation of two partially edentulous patients, both with surgically induced palatal defect and explains how to achieve the goal for esthetics and phonetics. This also describes the fabrication of a hollow obturator by two piece method, which is simple and may be used as definitive obturator for maximum comfort of the patient. In both the above cases, since the mouth opening is restricted due to surgery, obturator prosthesis is given as two pieces retained with opposite poles of magnet, which facilitates the removal and insertion of the prosthesis.

  3. Gait Kinematics After Taping in Participants With Chronic Ankle Instability

    PubMed Central

    Chinn, Lisa; Dicharry, Jay; Hart, Joseph M.; Saliba, Susan; Wilder, Robert; Hertel, Jay

    2014-01-01

    Context: Chronic ankle instability is characterized by repetitive lateral ankle sprains. Prophylactic ankle taping is a common intervention used to reduce the risk of ankle sprains. However, little research has been conducted to evaluate the effect ankle taping has on gait kinematics. Objective: To investigate the effect of taping on ankle and knee kinematics during walking and jogging in participants with chronic ankle instability. Design: Controlled laboratory study. Setting: Motion analysis laboratory. Patients or Participants: A total of 15 individuals (8 men, 7 women; age = 26.9 ± 6.8 years, height = 171.7 ± 6.3 cm, mass = 73.5 ± 10.7 kg) with self-reported chronic ankle instability volunteered. They had an average of 5.3 ± 3.1 incidences of ankle sprain. Intervention(s): Participants walked and jogged in shoes on a treadmill while untaped and taped. The tape technique was a traditional preventive taping procedure. Conditions were randomized. Main Outcome Measure(s): Frontal-plane and sagittal-plane ankle and sagittal-plane knee kinematics were recorded throughout the entire gait cycle. Group means and 90% confidence intervals were calculated, plotted, and inspected for percentages of the gait cycle in which the confidence intervals did not overlap. Results: During walking, participants were less plantar flexed from 64% to 69% of the gait cycle (mean difference = 5.73° ± 0.54°) and less inverted from 51% to 61% (mean difference = 4.34° ± 0.65°) and 76% to 81% (mean difference = 5.55° ± 0.54°) of the gait cycle when taped. During jogging, participants were less dorsiflexed from 12% to 21% (mean difference = 4.91° ± 0.18°) and less inverted from 47% to 58% (mean difference = 6.52° ± 0.12°) of the gait cycle when taped. No sagittal-plane knee kinematic differences were found. Conclusions: In those with chronic ankle instability, taping resulted in a more neutral ankle position during walking and jogging in shoes on a treadmill. This change in

  4. Magnetic Tape Recording for the Eighties

    NASA Technical Reports Server (NTRS)

    Kalil, Ford (Editor)

    1982-01-01

    The practical and theoretical aspects of state-of-the-art magnetic tape recording technology are reviewed. Topics covered include the following: (1) analog and digital magnetic tape recording, (2) tape and head wear, (3) wear testing, (4) magnetic tape certification, (5) care, handling, and management of magnetic tape, (6) cleaning, packing, and winding of magnetic tape, (7) tape reels, bands, and packaging, (8) coding techniques for high-density digital recording, and (9) tradeoffs of coding techniques.

  5. Accuracy testing of steel and electric groundwater-level measuring tapes: Test method and in-service tape accuracy

    USGS Publications Warehouse

    Fulford, Janice M.; Clayton, Christopher S.

    2015-10-09

    The calibration device and proposed method were used to calibrate a sample of in-service USGS steel and electric groundwater tapes. The sample of in-service groundwater steel tapes were in relatively good condition. All steel tapes, except one, were accurate to ±0.01 ft per 100 ft over their entire length. One steel tape, which had obvious damage in the first hundred feet, was marginally outside the accuracy of ±0.01 ft per 100 ft by 0.001 ft. The sample of in-service groundwater-level electric tapes were in a range of conditions—from like new, with cosmetic damage, to nonfunctional. The in-service electric tapes did not meet the USGS accuracy recommendation of ±0.01 ft. In-service electric tapes, except for the nonfunctional tape, were accurate to about ±0.03 ft per 100 ft. A comparison of new with in-service electric tapes found that steel-core electric tapes maintained their length and accuracy better than electric tapes without a steel core. The in-service steel tapes could be used as is and achieve USGS accuracy recommendations for groundwater-level measurements. The in-service electric tapes require tape corrections to achieve USGS accuracy recommendations for groundwater-level measurement.

  6. Transversal incision of the vagina favors the remaining of the tape in the middle-third urethra compared to longitudinal incision during transobturator sling procedures for stress urinary incontinence.

    PubMed

    Pirtea, L; Sas, I; Ilina, Razvan; Grigoraș, D; Mazilu, O

    2015-07-17

    To describe a new type of incision of the vagina during transobturator sling procedure and to evaluate by ultrasound the tape position at 3, 6 and 12 months after surgery. We conducted a prospective study including 51 patients with urinary stress incontinence who underwent sling procedure using the transversal vaginal incision. Tape position was evaluated by ultrasound at 3, 6 and 12 months after surgery and expressed as a percentage of the urethral length (the proximal third of the urethral length 0-39 %, the middle third 40-60 %, and the distal third 60-100 %). Informed consent was obtained from all patients prior to their inclusion in the study. All procedures have been performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki and its later amendments and were approved by the Institutional Review Board and Ethical Committee of "Victor Babeş" University of Medicine and Pharmacy Timisoara before the beginning of the study (no 7/17.04.2012). At 3 months after surgery, 3.92 % of the slings were located in the proximal third of the urethra, 88.23 % in the middle third of the urethra and 7.84 % in the distal third. At 6 and 12 months after surgery we obtained similar results: 9.81 % of the slings were located in the proximal third of the urethra, 82.35 % in the middle third and 7.84 % in the distal third of the urethra. The transversal incision of the vagina offers a minimal dissection along the long axis of the urethra favoring the remaining of the tape in the middle third of the urethra.

  7. Novel application of internal obturator and semitendinosus muscle flaps for rectal wall repair or reinforcement.

    PubMed

    Riggs, J; Ladlow, J F; Owen, L J; Hall, J L

    2018-01-29

    Internal obturator and/or semitendinosus muscle flaps were used to reinforce primary appositional rectal wall repair in three dogs and one cat in this case series. All three dogs incurred rectal wall compromise during surgical excision of anal sac tumours. The cat sustained bite wounds to the perianal region resulting in abscessation and a rectal tear. Our results indicate that application of an internal obturator and/or semitendinosus muscle flap can reduce the risk of rectal wall dehiscence after primary repair, and consequently the risk of pararectal abscess or rectocutaneous fistula formation. © 2018 British Small Animal Veterinary Association.

  8. Kinesio taping or sham taping in knee osteoarthritis? A randomized, double-blind, sham-controlled trial.

    PubMed

    Kocyigit, Figen; Turkmen, Mehmet Besir; Acar, Merve; Guldane, Nezahat; Kose, Tugce; Kuyucu, Ersin; Erdil, Mehmet

    2015-11-01

    To compare effects of kinesio taping with sham taping at the end of 3 consecutive taping periods in knee osteoarthritis. 41 patients diagnosed with knee osteoarthritis according to American College of Rheumatology were randomized to receive either KT or sham taping. Baseline evaluations included a visual analog scale (VAS) for activity and nocturnal pain, Lequesne index for functional assessment and Nottingham Health Profile (NHP) for the quality of life. Taping was applied every four days, three times, and all of the assessments were repeated at the end of the treatment period. In both groups VAS for activity pain, VAS for nocturnal pain, Lequesne index score, NHP score decreased significantly. NHP energy scores were different significantly between the groups in favor of sham taping at the end of the 12-day period. Our findings indicate inconclusive evidence of a beneficial effect of kinesio taping over sham taping in knee osteoarthritis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Effect of Tape Burnishing and Drive Use on Head Wear in Rotary Tape Drives

    NASA Astrophysics Data System (ADS)

    Bhushan, Bharat; Anderson, Reid M.; Koinkar, Vilas N.

    Three types of 12.7-mm wide metal particle tapes were studied. One of the tapes was calendered, whereas the other two tapes were additionally burnished one or two times using a proprietary process. Each type of tape was studied after 100 passes in the BetaCam SP drive and also in the virgin (0 pass) state. It was reported that in the case of the unburnished tape, head wear was high in the first pass and decreased during use. However, head wear for the double burnished tape was low for the first pass and increased during use. Whereas in the single burnished tape, head wear was low in the first pass and remained low. The objective of this study is to understand the mechanisms for loss and growth of head wear by correlating the surface characteristics of the tapes to head wear rate and to determine the changes in the surface characteristics occurring from 0 to 100 passes in the drive. It was found that summit density, mean and rms summit height, and mean and rms summit curvature correlate well to the head wear data. During manufacture and use in the drive, as the summit density, mean and rms summit height, and mean and rms summit curvature decrease, the head wear rate decreases. The mechanism for head wear is the initial ploughing of dense, sharp and high tape asperities into the surface of the head material resulting in a high head wear rate and a high coefficient of friction. Double burnishing during manufacturing removes high asperities, thus making the tape very smooth and possibly results in high adhesion and head wear growth with use. Chemical changes of the tape surface during double burnishing (not part of this study) also may be responsible for head wear growth during use.

  10. Main image file tape description

    USGS Publications Warehouse

    Warriner, Howard W.

    1980-01-01

    This Main Image File Tape document defines the data content and file structure of the Main Image File Tape (MIFT) produced by the EROS Data Center (EDC). This document also defines an INQUIRY tape, which is just a subset of the MIFT. The format of the INQUIRY tape is identical to the MIFT except for two records; therefore, with the exception of these two records (described elsewhere in this document), every remark made about the MIFT is true for the INQUIRY tape.

  11. Effect of different root canal obturating materials on push-out bond strength of a fiber dowel.

    PubMed

    Aggarwal, Vivek; Singla, Mamta; Miglani, Sanjay; Kohli, Sarita

    2012-07-01

    During dowel space preparation, the instrumentation forms a thick smear layer along with sealer-occluded dentinal tubules. The purpose of this study was to evaluate the effect of different obturating materials on push-out bond strength of a fiber dowel. Fifty human uniradicular teeth were decoronated and prepared using the step-back technique. The specimens were divided into five groups on the basis of obturating materials: group I received no obturation; group II (ZOE) gutta-percha and zinc oxide eugenol sealer; group III (ZOAH) gutta-percha and AH plus sealer; group IV (GF) GuttaFlow; and group V (RE) with Resilon Epiphany system. Dowel spaces were made with manufacturer's provided drills, and a fiber dowel was luted. Horizontal slices were obtained from the middle third, and push-out bond strength (S) was evaluated. Statistical analysis was carried out using one-way ANOVA and post hoc Tukey's test. The push-out bond strength values in the control group, ZOE, ZOAH, GF, and RE were 9.303 ± 0.565 MPa, 8.859 ± 0.539 MPa, 8.356 ± 0.618 MPa, 9.635 ± 0.435 MPa, and 8.572 ± 0.256 MPa, respectively. There was no statistically significant difference between the S values of all the groups (p > 0.05). There was no effect of different tested obturating materials on the push-out bond strength of fiber dowels; however, further studies should be conducted. © 2012 by the American College of Prosthodontists.

  12. Bacterial entombment by intratubular mineralization following orthograde mineral trioxide aggregate obturation: a scanning electron microscopy study

    PubMed Central

    Yoo, Jun Sang; Chang, Seok-Woo; Oh, So Ram; Perinpanayagam, Hiran; Lim, Sang-Min; Yoo, Yeon-Jee; Oh, Yeo-Rok; Woo, Sang-Bin; Han, Seung-Hyun; Zhu, Qiang; Kum, Kee-Yeon

    2014-01-01

    The time domain entombment of bacteria by intratubular mineralization following orthograde canal obturation with mineral trioxide aggregate (MTA) was studied by scanning electron microscopy (SEM). Single-rooted human premolars (n=60) were instrumented to an apical size #50/0.06 using ProFile and treated as follows: Group 1 (n=10) was filled with phosphate buffered saline (PBS); Group 2 (n=10) was incubated with Enterococcus faecalis for 3 weeks, and then filled with PBS; Group 3 (n=20) was obturated orthograde with a paste of OrthoMTA (BioMTA, Seoul, Korea) and PBS; and Group 4 (n=20) was incubated with E. faecalis for 3 weeks and then obturated with OrthoMTA–PBS paste. Following their treatments, the coronal openings were sealed with PBS-soaked cotton and intermediate restorative material (IRM), and the roots were then stored in PBS for 1, 2, 4, 8 or 16 weeks. After each incubation period, the roots were split and their dentin/MTA interfaces examined in both longitudinal and horizontal directions by SEM. There appeared to be an increase in intratubular mineralization over time in the OrthoMTA-filled roots (Groups 3 and 4). Furthermore, there was a gradual entombment of bacteria within the dentinal tubules in the E. faecalis inoculated MTA-filled roots (Group 4). Therefore, the orthograde obturation of root canals with OrthoMTA mixed with PBS may create a favorable environment for bacterial entombment by intratubular mineralization. PMID:25012869

  13. Results of the tension-free vaginal tape procedure for stress incontinence: patient's perspective.

    PubMed

    Manikandan, Ramaswamy; Kujawa, Magda; Pearson, Evelyn; O'Reilly, Patrick H; Brown, Stephen C W

    2004-04-01

    To evaluate the results of the tension-free vaginal tape procedure (TVT) from a patient's perspective. Between May 1999 and January 2002, 90 patients underwent a TVT for genuine stress incontinence (GSI) and mixed incontinence. Prior to the procedure, GSI was confirmed by clinical examination and urodynamic studies. Results were then audited from patient notes and the same patients were sent questionnaires to examine results from a patient perspective. Overall response rate to the questionnaire was 70 (77%). The mean age of the patients was 50.4 years (range 31-83 years). Sixty-one patients had spinal anesthesia, seven had general anesthesia and two had local anesthesia. Mean hospital stay was 3.36 days (range 2-14 days) and mean period from the operation to the time of the survey and audit was 16.34 months (range 3-28; SD 6.92). Thirty-nine (56%) of the 70 patients who answered said that the operation had cured their incontinence, 16 (23%) had an improvement in their symptoms, 7 (10%) had worsening of their symptoms and 8 (11%) felt that the operation did not make any difference. The overall success rate according to the patients' perspective was 79%, whereas our audit showed an overall success rate of 86% (77% and 82%, respectively, when we compared only the 66 patients who had both notes and replies available for analysis). Although a patient's perception regarding the success of TVT tends to differ from that of a clinician, it was not found to be statistically significant (P = 0.22, McNemar test). The TVT is a very successful operation, but realistic cure rates should be offered to patients.

  14. Use of binaural beat tapes for treatment of anxiety: a pilot study of tape preference and outcomes.

    PubMed

    Le Scouarnec, R P; Poirier, R M; Owens, J E; Gauthier, J; Taylor, A G; Foresman, P A

    2001-01-01

    Recent studies and anecdotal reports suggest that binaural auditory beats can affect mood, performance on vigilance tasks, and anxiety. To determine whether mildly anxious people would report decreased anxiety after listening daily for 1 month to tapes imbedded with tones that create binaural beats, and whether they would show a definite tape preference among 3 tapes. A 1-group pre-posttest pilot study. Patients' homes. A volunteer sample of 15 mildly anxious patients seen in the Clinique Psyché, Montreal, Quebec. Participants were asked to listen at least 5 times weekly for 4 weeks to 1 or more of 3 music tapes containing tones that produce binaural beats in the electroencephalogram delta/theta frequency range. Participants also were asked to record tape usage, tape preference, and anxiety ratings in a journal before and after listening to the tape or tapes. Anxiety ratings before and after tape listening, pre- and post-study State-Trait Anxiety Inventory scores, and tape preferences documented in daily journals. Listening to the binaural beat tapes resulted in a significant reduction in the anxiety score reported daily in patients' diaries. The number of times participants listened to the tapes in 4 weeks ranged from 10 to 17 (an average of 1.4 to 2.4 times per week) for approximately 30 minutes per session. End-of-study tape preferences indicated that slightly more participants preferred tape B, with its pronounced and extended patterns of binaural beats, over tapes A and C. Changes in pre- and posttest listening State-Trait Anxiety Inventory scores trended toward a reduction of anxiety, but these differences were not statistically significant. Listening to binaural beat tapes in the delta/theta electroencephalogram range may be beneficial in reducing mild anxiety. Future studies should account for music preference among participants and include age as a factor in outcomes, incentives to foster tape listening, and a physiologic measure of anxiety reduction. A

  15. Industrial Tape

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Scotch Brand Tape 364 was developed for NASA by 3M Company to protect electrical instrumentation coils and fluid lines from rocket launch blast conditions. It is an aluminized glass cloth tape which can withstand very high temperatures, is easily applied to compound surfaces, has excellent solar energy reflectance, and does not present an electrostatic hazard. It has potential automotive, transportation, and building construction applications.

  16. Oromaxillary Prosthetic Rehabilitation of a Maxillectomy Patient Using a Magnet Retained Two-Piece Hollow Bulb Definitive Obturator; A Clinical Report

    PubMed Central

    Mohamed Usman, Jafar Abdulla; Ayappan, Anuroopa; Ganapathy, Dhanraj; Nasir, Nilofer Nisha

    2013-01-01

    Resection of a malignant lesion involving the maxilla produces severe oromaxillary defect that can seriously jeopardize the normal phonetics of the patient. These defects are effectively managed by well-designed and fabricated obturator. This paper discusses the oromaxillary prosthetic rehabilitation of a maxillectomy patient using a magnet retained two-piece hollow bulb definitive obturator. PMID:23533823

  17. Postoperative pain after one-visit root-canal treatment on teeth with vital pulps: Comparison of three different obturation technique

    PubMed Central

    Alonso-Ezpeleta, Luis O.; Gasco-Garcia, Carmen; Castellanos-Cosano, Lizett; Martín-González, Jenifer; López-Frías, Francsico J.

    2012-01-01

    Objectives. To investigate and compare postoperative pain after one-visit root canal treatment (RCT) on teeth with vital pulps using three different obturation techniques. Study Design. Two hundred and four patients (105 men and 99 women) aged 12 to 77 years were randomly assigned into three treatments groups: cold lateral compaction of gutta-percha (LC), Thermafil technique (TT), and Backfill - Thermafil obturation technique (BT). Postoperative pain was recorded on a visual analogue scale (VAS) of 0 - 10 after 2 and 6 hours, and 1, 2, 3, 4, 5, 6 and 7 days. Data were statistically analyzed using multivariate logistic regression analysis. Results. In the total sample, 87% of patients experienced discomfort or pain in some moment between RCT and the seventh day. The discomfort experienced was weak, light, moderate and intense in 6%, 44%, 20% and 6% of the cases, respectively. Mean pain levels were 0.4 ± 0.4, 0.4 ± 0.3, and 1.4 ± 0.7 in LC, BT, and TT groups, respectively. Patients of TT group experienced a significantly higher mean pain level compared to other two groups (p < 0.0001). In TT group, all patients felt some level of pain at six hours after RCT. Conclusions. Postoperative pain was significantly associated with the obturation technique used during root canal treatment. Patients whose teeth were filled with Thermafil obturators (TT technique) showed significantly higher levels of discomfort than patients whose teeth were filled using any of the other two techniques. Key words:Postoperative pain, root-canal obturation, root-canal treatment, Thermafil. PMID:22322522

  18. Tape-Drop Transient Model for In-Situ Automated Tape Placement of Thermoplastic Composites

    NASA Technical Reports Server (NTRS)

    Costen, Robert C.; Marchello, Joseph M.

    1998-01-01

    Composite parts of nonuniform thickness can be fabricated by in-situ automated tape placement (ATP) if the tape can be started and stopped at interior points of the part instead of always at its edges. This technique is termed start/stop-on-the-part, or, alternatively, tape-add/tape-drop. The resulting thermal transients need to be managed in order to achieve net shape and maintain uniform interlaminar weld strength and crystallinity. Starting-on-the-part has been treated previously. This paper continues the study with a thermal analysis of stopping-on-the-part. The thermal source is switched off when the trailing end of the tape enters the nip region of the laydown/consolidation head. The thermal transient is determined by a Fourier-Laplace transform solution of the two-dimensional, time-dependent thermal transport equation. This solution requires that the Peclet number Pe (the dimensionless ratio of inertial to diffusive heat transport) be independent of time and much greater than 1. Plotted isotherms show that the trailing tape-end cools more rapidly than the downstream portions of tape. This cooling can weaken the bond near the tape end; however the length of the affected region is found to be less than 2 mm. To achieve net shape, the consolidation head must continue to move after cut-off until the temperature on the weld interface decreases to the glass transition temperature. The time and elapsed distance for this condition to occur are computed for the Langley ATP robot applying PEEK/carbon fiber composite tape and for two upgrades in robot performance. The elapsed distance after cut-off ranges from about 1 mm for the present robot to about 1 cm for the second upgrade.

  19. Hygroscopic properties of magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Cuddihy, E. F.

    1976-01-01

    Relative humidity has been recognized as an important environmental factor in many head-tape interface phenomena such as headwear, friction, staining, and tape shed. Accordingly, the relative humidity is usually specified in many applications of tape use, especially when tape recorders are enclosed in hermetically sealed cases. Normally, the relative humidity is believed regulated by humidification of the fill gas to the specification relative humidity. This study demonstrates that the internal relative humidity in a sealed case is completely controlled by the time-dpendence of the hygroscopic properties of the pack of magnetic recording tape. Differences are found in the hygroscopic properties of the same brand of tape, which apparently result from aging, and which may have an effect on the long-term humidity-regulating behavior in a sealed case, and on the occurrence of head-tape interface phenomena from the long-term use of the tape. Results are presented on the basic hygroscopic properties of magnetic tape, its humidity-regulating behavior in a sealed case, and a theoretical commentary on the relative humidity dependence of head-wear by tape, is included.

  20. The use of cone beam computed tomography and three dimensional printing technology in the restoration of a maxillectomy patient using a dental implant retained obturator.

    PubMed

    Michelinakis, George

    2017-01-01

    This case report presents an alternative method for fabricating an obturator for patients that develop xerostomia and mild trismus following radiation to the Head and Neck region. Multiple initial impression stages are avoided leading to less irritation to soft tissues and less discomfort to the patient. A 69-year-old male patient was referred to our dental practice by the Maxillofacial Surgery Department of the local General Hospital. The patient had undergone a right maxillectomy for removal of a Squamous Cell Carcinoma 2 weeks prior. Four endosseous dental implants were placed in the remaining upper jaw and 2 implants were inserted into the canine region of his edentulous mandible 3 weeks after ablative surgery. Five months following completion of radiotherapy and chemotherapy, a cone beam computed tomography of the maxilla was obtained, and a three dimensional model was constructed using an appropriate resin. Using the model as the detailed primary cast, a custom acrylic special tray was fabricated for the final impression of the remaining maxilla and the maxillary defect. An implant retained maxillary obturator and an implant retained mandibular overdenture were constructed to restore patient's speech, mastication and deglutition. The method presented here can limit the impression stages needed for construction of a maxillary obturator prosthesis to a single impression procedure advocating a partial digital workflow process. This can be very beneficial to the patient suffering from postradiation side-effects such as trismus, mucositis, and xerostomia.

  1. ICI optical data storage tape

    NASA Technical Reports Server (NTRS)

    Mclean, Robert A.; Duffy, Joseph F.

    1991-01-01

    Optical data storage tape is now a commercial reality. The world's first successful development of a digital optical tape system is complete. This is based on the Creo 1003 optical tape recorder with ICI 1012 write-once optical tape media. Several other optical tape drive development programs are underway, including one using the IBM 3480 style cartridge at LaserTape Systems. In order to understand the significance and potential of this step change in recording technology, it is useful to review the historical progress of optical storage. This has been slow to encroach on magnetic storage, and has not made any serious dent on the world's mountains of paper and microfilm. Some of the reasons for this are the long time needed for applications developers, systems integrators, and end users to take advantage of the potential storage capacity; access time and data transfer rate have traditionally been too slow for high-performance applications; and optical disk media has been expensive compared with magnetic tape. ICI's strategy in response to these concerns was to concentrate its efforts on flexible optical media; in particular optical tape. The manufacturing achievements, media characteristics, and media lifetime of optical media are discussed.

  2. Effect of Instrument Design and Access Outlines on the Removal of Root Canal Obturation Materials in Oval-shaped Canals.

    PubMed

    Niemi, Tuomas K; Marchesan, Melissa A; Lloyd, Adam; Seltzer, Robert J

    2016-10-01

    The aim of this study was to compare the effectiveness of TRUShape (TS) instruments with ProFile Vortex Blue (VB) instruments for the removal of obturation materials during retreatment of single-canal mandibular premolars performed through 2 access outlines. Initial root canal treatment was completed through a contracted endodontic cavity (CEC) design. Canals were instrumented to an F2 ProTaper instrument, obturated with warm lateral condensation of gutta-percha with AH Plus sealer, and allowed to set for 30 days at 37°C and 100% humidity. For retreatment, specimens were divided into 2 groups (n = 24) on the basis of access outline, CEC or traditional endodontic cavity (TEC). Retreatment was initiated by using ProTaper Retreatment instruments (D1-D3). Specimens were then stratified, further divided (n = 12), and reinstrumented up to TS 40 .06v or 40 .06 VB. Irrigation was performed by using 8.25% NaOCl and QMix 2in1. Retreatment time was recorded. Teeth were sectioned and photographed, and the percentage of remaining obturation materials was measured. Data were analyzed with Kruskal-Wallis analysis of variance for two-factor tests (α < 0.05). The interaction between access design and instrument type showed that the combination of CEC-VB presented significantly higher amounts of remaining obturation materials on the canal surface when compared with TEC-VB, CEC-TS, and TEC-TS (P ≤ .05). None of these other combinations were different from each other (P > .05). Significantly more time was required for retreatment with CEC-TS (27.68 ± 1.4 minutes) than the other groups (P < .05). Neither retreatment protocol was able to completely eliminate all obturation materials from the root canal surface of mandibular premolars. However, in the presence of a CEC access design, using TS instruments removed more obturating material in single-rooted, oval-shaped canals. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights

  3. Effect of kangaroo mother care vs expressed breast milk administration on pain associated with removal of adhesive tape in very low birth weight neonates: a randomized controlled trial.

    PubMed

    Nanavati, Ruchi N; Balan, Rajiv; Kabra, Nandkishor S

    2013-11-08

    To compare the pain relief effect of Kangaroo Mother Care (KMC) and Expressed Breast Milk (EBM) on the pain associated with adhesive tape removal in very low birth weight (VLBW) neonates. Randomized Controlled Trial. Neonatal intensive care unit of a tertiary care teaching hospital. 15 VLBW neonates who needed adhesive tape removal for the first part and 50 VLBW neonates needing adhesive tape removal for the second part. In first stage of the study, we studied whether adhesive tape removal in VLBW neonates was painful. In the second stage, eligible VLBW neonates were randomised to compare the efficacy of KMC and EBM in reducing the pain during the procedure of adhesive tape removal. Premature Infant Pain Profile (PIPP) Score, heart rate, oxygen saturation. There was significant increase in pain associated with the removal of adhesive tape (Mean pre-procedure PIPP score 3.47 ± 0.74; post-procedure mean PIPP score 12.13 ± 2.59; P<0.0001). The post intervention mean PIPP pain score was not significantly different between the KMC and EBM groups (P= 0.62). Removal of adhesive tape is a painful procedure for VLBW neonates. There was no difference between KMC and EBM in relieving pain associated with adhesive tape removal.

  4. Presence of Voids after Continuous Wave of Condensation and Single-cone Obturation in Mandibular Molars: A Micro-computed Tomography Analysis.

    PubMed

    Iglecias, Elaine Faga; Freire, Laila Gonzales; de Miranda Candeiro, George Táccio; Dos Santos, Marcelo; Antoniazzi, João Humberto; Gavini, Giulio

    2017-04-01

    The objective of this study was to assess the presence of voids in mesial root canals of mandibular molar teeth obturated by using the single-cone (SC) and continuous wave of condensation (CWC) obturation techniques, and results were analyzed by using micro-computed tomography. Twenty-four mandibular molars with fully developed roots and mesial root curvature ranging from 25° to 35° were instrumented by using Reciproc R25 files, and then they were obturated by using the SC and CWC techniques. Specimens were scanned before and after obturation for micro-computed tomography analysis (voxel size, 17.42 μm). After volumetric analysis and tridimensional reconstruction of the root canals, data were analyzed by using analysis of variance and the Tukey test. No significant differences were observed between the 2 techniques in terms of total percentage volume of voids: CWC = 3.91% ± 0.72%; SC = 6.52% ± 1.16% (P > .05). Only in the cervical third, CWC showed a significantly lower percentage of voids when compared with SC, namely 2.86% ± 0.94% vs 8.00% ± 1.86%, respectively (P < .05). The percentage volume of voids was similar in the 2 groups and was influenced by the obturation technique only in the cervical third. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  5. NASA Global Atmospheric Sampling Program (GASP) data report for tape VL0005

    NASA Technical Reports Server (NTRS)

    Holdeman, J. D.; Humenik, F. M.

    1977-01-01

    Atmospheric ozone, water vapor, and related flight and meteorological data were obtained during 214 flights of a United Airlines B-747 and two Pan American World Airways B-747's from March through June 1976. In addition, trichlorofluoromethane data obtained from laboratory analysis of two whole air samples collected in flight are reported. These data are available on GASP tape VL0005 from the National Climatic Center, Asheville, North Carolina. In addition to the GASP data, tropopause pressure fields obtained from NMC archives for the dates of the GASP flights are included on the data tape. Flight routes and dates, instrumentation, data processing procedures, and data tape specifications are described in this report. Selected analyses including ozone and sample bottle data are also presented.

  6. Automated Tape Laying Machine for Composite Structures.

    DTIC Science & Technology

    The invention comprises an automated tape laying machine, for laying tape on a composite structure. The tape laying machine has a tape laying head...neatly cut. The automated tape laying device utilizes narrow width tape to increase machine flexibility and reduce wastage.

  7. Detection of latent fingerprint hidden beneath adhesive tape by optical coherence tomography.

    PubMed

    Zhang, Ning; Wang, Chengming; Sun, Zhenwen; Li, Zhigang; Xie, Lanchi; Yan, Yuwen; Xu, Lei; Guo, Jingjing; Huang, Wei; Li, Zhihui; Xue, Jing; Liu, Huan; Xu, Xiaojing

    2018-06-01

    Adhesive tape is one type of common item which can be encountered in criminal cases involving rape, murder, kidnapping and explosives. It is often the case that a suspect deposits latent fingerprints on the sticky side of adhesive tape material when tying up victims, manufacturing improvised explosive devices or packaging illegal goods. However, the adhesive tapes found at crime scenes are usually stuck together or attached to a certain substrate, and thus the latent fingerprints may be hidden beneath the tapes. Current methods to detect latent fingerprint hidden beneath adhesive tape need to peel it off first and then apply physical or chemical methods to develop the fingerprint, which undergo complicated procedures and would affect the original condition of latent print. Optical coherence tomography (OCT) is a novel applied techniques in forensics which enables obtaining cross-sectional structure with the advantages of non-invasive, in-situ, high resolution and high speed. In this paper, a custom-built spectral-domain OCT (SD-OCT) system with a hand-held probe was employed to detect fingerprints hidden beneath different types of adhesive tapes. Three-dimensional (3D) OCT reconstructions were performed and the en face images were presented to reveal the hidden fingerprints. The results demonstrate that OCT is a promising tool for rapidly detecting and recovering high quality image of latent fingerprint hidden beneath adhesive tape without any changes to the original state and preserve the integrity of the evidence. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Effects of a paraspinal-lumbar tape application during 7 days on the perceived area of tape contact.

    PubMed

    Funk, Stefan; Finke, Roy; Zeh, Stefan; Siebert, Tobias; Puta, Christian

    2017-05-01

    The study aimed to investigate the changes of the perceived area of tape contact during a lumbar tape application that lasted 7 days. Single group, repeated measures study. University research laboratory. Twenty-three healthy collegiate students in sports science. Perceived area of tape contact was collected by preparing a drawing of their individual perceived tape outline into a printed body image. Measurements were obtained immediately after fixation of the tape (day 0), at day 3 and day 7 during application and 5 min after the release of the application (day 7). There was no significant change of the perceived area of tape contact after 3 days of tape application. A significant decrease in the perceived area of tape contact was detected 7 days after application (p < 0.05) and after detaching the tape (p < 0.01) compared to the first measurement. Our results indicate that the perception of the area of tape contact of healthy sport students is decreased at 7 days. This effect could not be observed at 3 days. These results provide relevant information for the use of elastic tapes concerning the duration of application in medical therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. In vitro comparison of gutta-percha-filled area percentages in root canals instrumented and obturated with different techniques.

    PubMed

    Yilmaz, Ayca; Karagoz-Kucukay, Isil

    2017-01-01

    To evaluate the efficacy of different obturation techniques in root canals instrumented either by hand or rotary instruments with regard to the percentage of gutta- percha-filled area (PGFA). One hundred and sixty extracted mandibular premolars with single, straight root canals were studied. Root canals were prepared to an apical size of 30 by hand with a modified crown-down technique or the ProTaper and HEROShaper systems. Teeth were divided into eight groups (n=20) according to the following instrumentation and obturation techniques: G1: Hand files+lateral condensation (LC), G2: Hand files+Thermafil, G3: ProTaper+LC, G4: ProTaper+single-cone, G5: ProTaper+ProTaper-Obturator, G6: HEROShaper+LC, G7: HEROShaper+single-cone, G8: HEROShaper+HEROfill. Horizontal sections were cut at 1, 3, 5, 7, 9, 11 and 13 mm from the apical foramen. A total of 1120 sections obtained were digitally photographed under a stereomicroscope set at 48X magnification. The cross-sectional area of the canal and the gutta-percha was measured by digital image analysis and the PGFA was calculated for each section. The mean of the PGFA in Thermafil (G2), ProTaper-Obturator (G5) and HEROfill (G8) groups was significantly higher than the other groups. In G3 and G4, PGFA showed no significant difference in the apical segments whereas PGFA was significantly higher at the middle and coronal segments in G3. In G6 and G7, PGFA showed no significant difference in the apical and middle segments whereas PGFA was significantly higher at the coronal segments in G6. The carrier-based gutta-percha obturation systems revealed significantly higher PGFA in comparison to single-cone and lateral condensation techniques.

  10. Functional and morphological differences following Monarc and TVT-O procedures.

    PubMed

    Huang, W-C; Yang, S-H; Yang, J-M; Tzeng, C-R

    2012-12-01

    To explore function of the lower urinary tract and morphology of tape and urethra following Monarc or TVT-O suburethral tape placement for urodynamic stress incontinence (USI). We recruited prospectively women undergoing either Monarc or TVT-O placement for USI. Before and 3 months after the procedure, participants were evaluated by a question-directed interview, the measures of Sandvik Incontinence Severity Index (SISI), Incontinence Bother Scale (IBS), Ingelman-Sundberg Score (ISS) and short forms of Urogenital Distress Inventory (UDI-6) and Incontinence Impact Questionnaire (IIQ-7), physical examination, a cough stress test and 4D ultrasound investigation. The primary outcome was participants' responses to clinical assessments and the secondary outcome was ultrasound findings. A total of 67 women with Monarc procedures and 60 women with TVT-O procedures completed the survey both preoperatively and 3 months postoperatively. There were significant improvements in scores of SISI, IBS, ISS, UDI-6 and IIQ-7 after both Monarc and TVT-O procedures. At the 3-month follow-up, both procedures had similar success rates, SISI scores, IBS scores, ISS scores, UDI-6 scores and IIQ-7 scores, and similar incidences of postoperative voiding difficulty and overactive bladder symptoms. After Bonferroni correction, all ultrasound parameters representing tape location, tape tension and urethral mobility were similar between the two procedures. At short-term follow-up, Monarc and TVT-O procedures are comparable in both functional outcome of the lower urinary tract and morphology on ultrasound as assessed by parameters representing tape location, tape tension and urethral mobility. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  11. Tape recorder failure investigation

    NASA Technical Reports Server (NTRS)

    Higgins, M. D.; Loewenthal, S. H.; Carnahan, C. C.; Snyder, G. L.

    1996-01-01

    Two end-item tape recorders lost 4:1 mode data recording mode capability at less than half of their 1 6,000-cycle, 4-year operating life. Subsequent life tests on two spare recorders also experienced 4:1 mode data loss at 8,000 and 11,700 cycles. Tear down inspection after completion of the life tests showed that the tape had worn through the alfesil record and reproduce heads. An investigation was initiated to understand the cause of excessive tape head wear and the reasons why the 4:1 mode data rate, low-speed mode is more damaging than the 1:1 mode data rate, high-speed recording mode. The objective was to establish how operating conditions (tape speed, humidity, temperature, stop/start cycles) affects head life with the goal of extending head life on the remaining in-service tape recorders. Another interest was to explain why an earlier vendor life test showed capability beyond 16,000 cycles.

  12. An ex vivo comparison of pressures within dental pulp space using conventional anesthetic technique versus needle-mounted obturator.

    PubMed

    Grubbs, S Lee; Alley, Larry W; Eleazer, Paul D

    2014-07-01

    The intrapulpal (IP) injection technique is 1 of several ways of obtaining profound anesthesia. There is evidence to suggest that pressure is the primary factor in obtaining anesthesia using IP injection. This is an ex vivo comparison of pressures within dental pulp space using the conventional anesthetic technique versus a needle-mounted obturator technique. Twenty extracted anterior and premolar teeth were accessed with a high-speed 169L bur. A saline-filled tube connected to a digital pressure gauge was attached to the apical 10 mm of each tooth in a fixed mount. One operator performed all the injections under moderate pressure. Each tooth was injected twice; first, the tooth was given an IP injection with a normal setup, and then the same tooth was given an IP injection with the modified obturator syringe. The pressure at the apex was recorded for each tooth. A paired sample t test was completed to determine statistical significance. The pressure generated was considerably higher for the obturator group in every tooth when compared with the normal group (P < .001). IP injection with the obturator resulted in increased pressure at the apex of each tooth. This pressure increase may allow for increased anesthesia when IP injections are indicated. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  13. A comparison of root surface temperatures using different obturation heat sources.

    PubMed

    Lee, F S; Van Cura, J E; BeGole, E

    1998-09-01

    This study compared root surface temperatures produced during warm vertical obturation using the System B Heat Source (SB), the Touch 'n Heat device (TH), and a flame-heated carrier (FH). The root canals of 30 maxillary incisor, premolar, and mandibular incisor teeth were prepared; divided into three groups; and obturated using each heat source. A thermocouple placed 2 mm below the cementoenamel junction transferred the temperature rise on the external root surface to a digital thermometer. SB surface temperature rise was < 10 degrees C for all experimental teeth. TH temperature rise in maxillary incisors and premolars was < 10 degrees C; however, > 10 degrees C was observed for mandibular incisors. FH produced a > 10 degrees C surface temperature rise in all experimental teeth. The critical level of root surface heat required to produce irreversible bone damage is believed to be > 10 degrees C. The findings of this study suggest that warm vertical condensation with the SB should not damage supporting periradicular tissues. However, caution should be used with TH and FH on mandibular incisors.

  14. Visualization of latent fingerprints beneath opaque electrical tapes by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Liu, Kangkang; Zhang, Ning; Meng, Li; Li, Zhigang; Xu, Xiaojing

    2018-03-01

    Electrical tape is found as one type of important trace evidence in crime scene. For example, it is very frequently used to insulate wires in explosive devices in many criminal cases. The fingerprints of the suspects were often left on the adhesive side of the tapes, which can provide very useful clues for the investigation and make it possible for individual identification. The most commonly used method to detect and visualize those latent fingerprints is to peel off each layer of the tapes first and then adopt the chemical methods to develop the fingerprints on the tapes. However, the peeling-off and chemical development process would degrade and contaminate the fingerprints and thus adversely affect the accuracy of identification. Optical coherence tomography (OCT) is a novel forensic imaging modality based on lowcoherence interferometry, which has the advantages of non-destruction, micrometer-level high resolution and crosssectional imaging. In this study, a fiber-based spectral-domain OCT (SD-OCT) system with {6μm resolution was employed to obtain the image of fingerprint sandwiched between two opaque electrical tapes without any pre-processing procedure like peeling-off. Three-dimensional (3D) OCT reconstruction was performed and the subsurface image was produced to visualize the latent fingerprints. The results demonstrate that OCT is a promising tool for recovering the latent fingerprints hidden beneath opaque electrical tape non-destructively and rapidly.

  15. Analysis of cache for streaming tape drive

    NASA Technical Reports Server (NTRS)

    Chinnaswamy, V.

    1993-01-01

    A tape subsystem consists of a controller and a tape drive. Tapes are used for backup, data interchange, and software distribution. The backup operation is addressed. During a backup operation, data is read from disk, processed in CPU, and then sent to tape. The processing speeds of a disk subsystem, CPU, and a tape subsystem are likely to be different. A powerful CPU can read data from a fast disk, process it, and supply the data to the tape subsystem at a faster rate than the tape subsystem can handle. On the other hand, a slow disk drive and a slow CPU may not be able to supply data fast enough to keep a tape drive busy all the time. The backup process may supply data to tape drive in bursts. Each burst may be followed by an idle period. Depending on the nature of the file distribution in the disk, the input stream to the tape subsystem may vary significantly during backup. To compensate for these differences and optimize the utilization of a tape subsystem, a cache or buffer is introduced in the tape controller. Most of the tape drives today are streaming tape drives. A streaming tape drive goes into reposition when there is no data from the controller. Once the drive goes into reposition, the controller can receive data, but it cannot supply data to the tape drive until the drive completes its reposition. A controller can also receive data from the host and send data to the tape drive at the same time. The relationship of cache size, host transfer rate, drive transfer rate, reposition, and ramp up times for optimal performance of the tape subsystem are investigated. Formulas developed will also show the advantages of cache watermarks to increase the streaming time of the tape drive, maximum loss due to insufficient cache, tradeoffs between cache and reposition times and the effectiveness of cache on a streaming tape drive due to idle times or interruptions due in host transfers. Several mathematical formulas are developed to predict the performance of the tape

  16. Neurofibroma involving obturator nerve mimicking an adnexal mass: a rare case report and PRISMA-driven systematic review.

    PubMed

    Chao, Wei-Ting; Liu, Chia-Hao; Chen, Yi-Jen; Wu, Hua-Hsi; Chuang, Chi-Mu; Wang, Peng-Hui

    2018-02-09

    Pelvic masses are a common gynecologic problem, and majority of them are diagnosed as ovarian tumors finally. Sometimes, it is hard to distinguish the origin of these pelvic masses. The following case is a solitary neurofibroma arising from the right-side obturator nerve, which was impressed as a right-side ovarian tumor initially. We reported this case, and also performed a PRISMA-driven systematic review to summary the similar cases in the literature. This review includes image, molecular and pathological findings and outcome of neurofibroma. A 33-year-old woman with a regular menstrual period denied any symptoms or signs. During her physical check-up, image examination revealed a right-side heterogeneous pelvic mass; it was suggestive of a complex of right-side ovarian tumor. A provisional diagnosis of retroperitoneal pelvic mass, probably a benign ovarian tumor, was made. Excision of the right-side pelvic mass was performed. We sent the specimens for frozen pathology, which indicated neurofibroma and lipomatous tumor and that the possibility of liposarcoma cannot be excluded. A segment of the obturator nerve was attached to the tumor and was severed. A right-side obturator nerve tear during tumor excision was observed, and a neurosurgeon was consulted for obturator nerve grafting and repair. The patient complained of mild weakness and paresthesia affecting the right leg, and we consulted a rehabilitation doctor for neuron injury. The patient's recovery was uneventful, and she was discharged eight days after the drain was removed. Further rehabilitation treatment was arranged. A neurofibroma is an uncommon pelvic retroperitoneal tumor, and it can be misdiagnosed as an adnexal mass. To our knowledge, this is a rare case of a solitary neurofibroma arising from the obturator nerve. It usually does not have any neurological deficit. We present this case to demonstrate that pelvic neurofibroma can be mistaken for an adnexal mass. This fact should be borne in mind

  17. Krytox Lubrication Tape Study. [fluorinated lubricating oil for video tape recorders

    NASA Technical Reports Server (NTRS)

    Lee, F.

    1978-01-01

    The use of Krytox, a fluorinated oil, as a tape surface lubricant was studied for a wideband video tape recorder. In spite of the 5 to 1 head wear reduction credited to the surface lubricant, the resultant head life fell short of the 1500 hour goal.

  18. New technique to fabricate an immediate surgical obturator restoring the defect in original anatomical form.

    PubMed

    Patil, Pravinkumar G

    2011-08-01

    The presence of oral cancer can necessitate the surgical removal of all or part of the maxilla, leaving the patient with a defect compromising the oral cavity's integrity and function. The immediate postoperative restoration of esthetics, deglutition, and speech shortens recovery time in the hospital and expedites the patient's return to the community as a functioning member. This article describes a simple technique to fabricate an immediate surgical obturator by restoring the patient's original dentition and facial and palatal tissue form. An immediate obturator fabricated with this technique supports soft tissues after surgery and minimizes scar contracture and disfigurement and thus may have a positive effect on the patient's psychology. © 2011 by The American College of Prosthodontists.

  19. Digital tape unit test facility software

    NASA Technical Reports Server (NTRS)

    Jackson, J. T.

    1971-01-01

    Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

  20. An In vitro Comparison and Evaluation of Sealing Ability of Newly Introduced C-point System, Cold Lateral Condensation, and Thermoplasticized Gutta-Percha Obturating Technique: A Dye Extraction Study.

    PubMed

    Sinhal, Tapati Manohar; Shah, Ruchi Rani Purvesh; Jais, Pratik Subhas; Shah, Nimisha Chinmay; Hadwani, Krupali Dhirubhai; Rothe, Tushar; Sinhal, Neha Nilesh

    2018-01-01

    The aim of this study is to compare and to evaluate sealing ability of newly introduced C-point system, cold lateral condensation, and thermoplasticized gutta-percha obturating technique using a dye extraction method. Sixty extracted maxillary central incisors were decoronated below the cementoenamel junction. Working length was established, and biomechanical preparation was done using K3 rotary files with standard irrigation protocol. Teeth were divided into three groups according to the obturation protocol; Group I-Cold lateral condensation, Group II-Thermoplasticized gutta-percha, and Group III-C-Point obturating system. After obturation all samples were subjected to microleakage assessment using dye extraction method. Obtained scores will be statistical analyzed using ANOVA test and post hoc Tukey's test. One-way analysis of variance revealed that there is significant difference among the three groups with P value (0.000 < 0.05). Tukey's HSD post hoc tests for multiple comparisons test shows that the Group II and III perform significantly better than Group I. Group III performs better than Group II with no significant difference. All the obturating technique showed some degree of microleakage. Root canals filled with C-point system showed least microleakage followed by thermoplasticized obturating technique with no significant difference among them. C-point obturation system could be an alternative to the cold lateral condensation technique.

  1. Sabots, Obturator and Gas-In-Launch Tube Techniques for Heat Flux Models in Ballistic Ranges

    NASA Technical Reports Server (NTRS)

    Bogdanoff, David W.; Wilder, Michael C.

    2013-01-01

    For thermal protection system (heat shield) design for space vehicle entry into earth and other planetary atmospheres, it is essential to know the augmentation of the heat flux due to vehicle surface roughness. At the NASA Ames Hypervelocity Free Flight Aerodynamic Facility (HFFAF) ballistic range, a campaign of heat flux studies on rough models, using infrared camera techniques, has been initiated. Several phenomena can interfere with obtaining good heat flux data when using this measuring technique. These include leakage of the hot drive gas in the gun barrel through joints in the sabot (model carrier) to create spurious thermal imprints on the model forebody, deposition of sabot material on the model forebody, thereby changing the thermal properties of the model surface and unknown in-barrel heating of the model. This report presents developments in launch techniques to greatly reduce or eliminate these problems. The techniques include the use of obturator cups behind the launch package, enclosed versus open front sabot designs and the use of hydrogen gas in the launch tube. Attention also had to be paid to the problem of the obturator drafting behind the model and impacting the model. Of the techniques presented, the obturator cups and hydrogen in the launch tube were successful when properly implemented

  2. Prosthetic reconstruction with an obturator using swing-lock attachment for a patient underwent maxillectomy: A clinical report

    PubMed Central

    2016-01-01

    Patients who underwent resection of maxilla due to benign or malignant tumor, or accident will have defect in palatal area. They get retention, support and stability from remaining tissues which are hardly optimal. The advantage of swing-lock attachment design is having multiple contacts on labial and lingual side of the abutment teeth by retentive strut and palatal bracing component. Because the force is distributed equally to abutment teeth, abutment teeth of poor prognosis can be benefited from it. It is also more advantageous to cover soft tissue defects which are hard to reach with conventional prosthesis. A 56-year-old female patient who had undergone a maxillectomy due to malignant melanoma complaining of loose and unstable surgical obturator. Surveyed crowns were placed on #12, 26, and 27. Teeth #11, 21, 22, and 23 had lingual rest seat and #24 had mesial rest seat to improve stability and support of the obturator. This clinical report presents the prosthetic management of a patient treated with obturator on the maxilla using swing-lock attachment to the remaining teeth. PMID:27826392

  3. Sealing ability of lateral condensation, thermoplasticized gutta-percha and flowable gutta-percha obturation techniques: A comparative in vitro study.

    PubMed

    Kumar, Nallkkapalayam Somasundaram Mohan; Prabu, P S; Prabu, Neethika; Rathinasamy, Shobana

    2012-08-01

    To evaluate and compare the sealing ability between the clod lateral condensation, thermoplasticized gutta-percha, and flowable gutta-percha obturation technique, under a stereomicroscope at ×40 magnification. Sixty single rooted teeth were selected and canals were shaped with K3 NiTi files. Irrigation was performed with 5.25% NaOCl and 17% ethylenediaminetetraacetic acid (EDTA). The teeth were then separated into three groups depending on the type of obturation technique: Group A, obturated using the lateral condensation technique and AH Plus sealer; Group B, obturated with thermoplasticized gutta-percha tech (Obtura III Max) and AH Plus sealer; and Group C, obturated using flowable gutta-percha technique (GuttaFlow). After storing the teeth in 100% humidity for 7 days at 37°C, the roots of the teeth were sectioned at five levels. The sections were then observed under a stereomicroscope at ×40 magnification and the images were analyzed for area of voids (AV) and frequency of voids. The data were statistically analyzed using the SPSS version 17 software. The 95% confidence intervals (CI) were calculated. One-way analysis of variance with post hoc test and non-parametric Mann-Whitney U test were carried out to compare the means. The lowest mean of AV was recorded in the thermoplasticized gutta-percha (Obtura III Max) group [1.0% (95% CI=0.5-1.5)]. This was statistically and significantly different from flowable gutta-percha (GuttaFlow) group [3.0% (95% CI=2.1-3.9)]. There was no significant difference between the thermoplasticized gutta-percha group and lateral condensation group [1.6% (95% CI=1.0-2.2)] with regard to the AV, but there was a statistically significant difference between the lateral condensation and flowable gutta-percha groups. The flowable gutta-percha group showed the maximum number of voids [56% (95% CI=48-64)], which was significantly higher than those in the lateral condensation [26% (95% CI=19-34)] and thermoplasticized gutta-percha [15% (95

  4. Quick-release medical tape

    PubMed Central

    Laulicht, Bryan; Langer, Robert; Karp, Jeffrey M.

    2012-01-01

    Medical tape that provides secure fixation of life-sustaining and -monitoring devices with quick, easy, damage-free removal represents a longstanding unmet medical need in neonatal care. During removal of current medical tapes, crack propagation occurs at the adhesive–skin interface, which is also the interface responsible for device fixation. By designing quick-release medical tape to undergo crack propagation between the backing and adhesive layers, we decouple removal and device fixation, enabling dual functionality. We created an ordered adhesive/antiadhesive composite intermediary layer between the medical tape backing and adhesive for which we achieve tunable peel removal force, while maintaining high shear adhesion to secure medical devices. We elucidate the relationship between the spatial ordering of adhesive and antiadhesive regions to create a fully tunable system that achieves strong device fixation and quick, easy, damage-free device removal. We also described ways of neutralizing the residual adhesive on the skin and have observed that thick continuous films of adhesive are easier to remove than the thin islands associated with residual adhesive left by current medical tapes. PMID:23112196

  5. Guide to the TANDEM System for the Modern Languages Department Tape Library: A Non-Technical Guide for Teachers.

    ERIC Educational Resources Information Center

    Hounsell, D.; And Others

    This guide for teachers to the tape indexing system (TANDEM) in use at the Modern Languages Department at Portsmouth Polytechnic focuses on tape classification, numbering, labeling, and shelving system procedures. The appendixes contain information on: (1) the classification system and related codes, (2) color and letter codes, (3) marking of tape…

  6. Tracer sensitive tapes

    NASA Technical Reports Server (NTRS)

    Burrows, W. H.; Burrows, W. H.

    1971-01-01

    A leak detection system has been developed, consisting of a tape that can be wrapped around possible leak sites on a system pressurized with air or gaseous nitrogen. Carbon monoxide, at a level of 100 to 1000 parts per million is used as a trace gas in the pressurized system. The sensitive element of the tape is palladium chloride supported on specially prepared silica gel and specially dried. At a CO level of 100 ppm and a leak rate of 10-20 ml/hr, discoloration of the sensitive element is observed in 1.5 to 3 min. The tape and trace gas are compatible with aerospace hardware, safe to handle, and economically reasonable to produce and handle.

  7. Efficacy and safety of TVT-O and TVT-Secur in the treatment of female stress urinary incontinence: 1-year follow-up.

    PubMed

    Tommaselli, Giovanni A; Di Carlo, Costantino; Gargano, Virginia; Formisano, Carmen; Scala, Mariamaddalena; Nappi, Carmine

    2010-10-01

    To reduce complications of transobturator tension-free vaginal tape, single-incision devices were introduced in the last years. We here report a comparison between the tension-free vaginal tape-obturator (TVT-O) and the TVT-Secur techniques in terms of efficacy and safety. Eighty-four patients with stress urinary incontinence (SUI) were scheduled to undergo TVT-O or TVT-Secur. Duration of the procedure, subjective estimate of blood loss, intraoperative and postoperative complications, postoperative postvoidal residue (PVR), time to first voiding, and pain level were recorded. Urodynamic tests, PVR, Incontinence Questionnaire Short Form (ICIQ-SF), King's Health Questionnaire, and a urinary diary were performed before and 12 months after procedure. No differences in terms of cure rate were observed between the two groups (81.6% vs. 83.8%). Complication rate in the TVT-Secur group was lower (8.1%) than in the TVT-O group (15.8%), but not significant. Both techniques seem to be effective and safe, with a low incidence of complications in both groups.

  8. Photoelastic analysis to compare implant-retained and conventional obturator dentures

    NASA Astrophysics Data System (ADS)

    Goiato, Marcelo Coelho; Prado Ribeiro, Paula do; Pellizzer, Eduardo Piza; Pesqueira, Aldiéris Alves; Haddad, Marcela Filiè; dos Santos, Daniela Micheline; Moreno, Amália

    2012-06-01

    The use of photoelastic analysis contributes to the rehabilitation of patients with oral-sinus-nasal sequelae, which in turn affect important functions such as chewing, swallowing, and speech. The prosthetic rehabilitation with implant-retained dentures is a suitable treatment option. The purpose of this study was to verify, by using a photoelastic analysis, the stress distribution in implant-retained palatal obturator dentures (relined or not) associated with different attachment systems (O-ring, bar-clip, and bar-clip associated with distally placed O-rings). Two photoelastic models were obtained from an experimental maxillary cast presenting an oral-nasal communication. One model had two 13-mm length implants placed on the left region. A total of eight colorless maxillary obturators were fabricated and subsequently four of them were relined with soft silicone soft, and three had attachment systems associated. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope and a 100-N load was applied at 10 mm/s. The results showed that the denture relining influenced the distribution and amount of stress on the models. The O-ring group displayed the lowest stress levels, followed by bar-clip system associated with distally placed O-rings and bar-clip groups.

  9. The safety and efficacy of the "inside-out" trans-obturator TVT in elderly versus younger stress-incontinent women: a prospective study of 353 consecutive patients.

    PubMed

    Groutz, Asnat; Cohen, Aviad; Gold, Ronen; Pauzner, David; Lessing, Joseph B; Gordon, David

    2011-03-01

    To analyze the safety and efficacy of the trans-obturator tension-free vaginal tape (TVT-O) in elderly versus younger stress-incontinent women. Ninety-seven consecutive elderly, aged 70 and older, and 256 younger women (mean age 75 and 55 years, respectively) who underwent TVT-O for urodynamically confirmed stress urinary incontinence (SUI) were prospectively enrolled. Concomitant pelvic organ prolapse (POP) repair was performed in 90% of the elderly and 70% of the younger women. The surgical procedures, as well as all pre- and postoperative clinical and urodynamic evaluation, were performed in one university-affiliated medical center. Main outcome measures were operative complications, early and late postoperative morbidity, postoperative urodynamically confirmed SUI (symptomatic, or asymptomatic), persistent, or de novo overactive bladder (OAB) and bladder outlet obstruction (BOO). Mean follow-up of the patients was 30 ± 17 months (range 3-58 months). Early and late postoperative morbidity was similar in both groups, except for significantly more cases of postoperative recurrent UTI's among elderly women (13.7% vs. 6.2%). The incidence of persistent urodynamically confirmed overt SUI was similar in both age groups (5%). However, asymptomatic urodynamic SUI was significantly more common among elderly patients (19% vs. 3.7%, P<0.05). The incidence of persistent OAB was similar in elderly and younger patients (68% and 62%, respectively), while de novo OAB was significantly more common in elderly patients (11.9% vs. 4.7%, P<0.05). TVT-O is safe and efficient for both elderly and younger stress-incontinent women. However, elderly patients are in increased risk for postoperative recurrent UTI's as well as de novo OAB. Copyright © 2010 Wiley-Liss, Inc.

  10. Effect of tape recording on perturbation measures.

    PubMed

    Jiang, J; Lin, E; Hanson, D G

    1998-10-01

    Tape recorders have been shown to affect measures of voice perturbation. Few studies, however, have been conducted to quantitatively justify the use or exclusion of certain types of recorders in voice perturbation studies. This study used sinusoidal and triangular waves and synthesized vowels to compare perturbation measures extracted from directly digitized signals with those recorded and played back through various tape recorders, including 3 models of digital audio tape recorders, 2 models of analog audio cassette tape recorders, and 2 models of video tape recorders. Signal contamination for frequency perturbation values was found to be consistently minimal with digital recorders (percent jitter = 0.01%-0.02%), mildly increased with video recorders (0.05%-0.10%), moderately increased with a high-quality analog audio cassette tape recorder (0.15%), and most prominent with a low-quality analog audio cassette tape recorder (0.24%). Recorder effect on amplitude perturbation measures was lowest in digital recorders (percent shimmer = 0.09%-0.20%), mildly to moderately increased in video recorders and a high-quality analog audio cassette tape recorder (0.25%-0.45%), and most prominent in a low-quality analog audio cassette tape recorder (0.98%). The effect of cassette tape material, length of spooled tape, and duration of analysis were also tested and are discussed.

  11. Enhancing contrast of fingerprints on plastic tape.

    PubMed

    Steele, Charles A; Ball, Mikki S

    2003-11-01

    Many of the currently available fingerprinting methods have limited ability to visualize fingerprints on plastic tape without expensive equipment or significant handling of the sample. This is especially true for visualizing fingerprints on black electrical tape. This study sought a hands-off method to produce easy visualization of fingerprints on different types of plastic tape, including black electrical tape, without the need for expensive equipment. The methods selected were to sublime disperse dyes into the tape, both with and without the fuming of cyanoacrylate, everywhere except for where the fingerprint was applied. The resulting color contrasts provided enough differentiation to visualize fingerprints on plastic tape under ambient light. Sequential fuming with cyanoacrylate followed by disperse dyes provided the best visualizations on all tapes, and cyanoacrylate followed by disperse yellow 211 clearly visualized fingerprints on black electrical tape.

  12. EROS to universal tape conversion processor

    NASA Technical Reports Server (NTRS)

    Obrien, S. O. (Principal Investigator)

    1980-01-01

    The function of the EROS processor is to allow a user to select a specific area from a full frame LANDSAT image which is written on tape in the EROS format. The area of interest is read from the EROS formatted tape and converted to the JSC Universal format and written onto another tape. This tape can then be read by the IMDACS processing system and normal analysis can be performed.

  13. ICI optical data storage tape

    NASA Technical Reports Server (NTRS)

    Mclean, Robert A.; Duffy, Joseph F.

    1992-01-01

    Optical data storage tape is now a commercial reality. The world's first successful development of a digital optical tape system is complete. This is based on the Creo 1003 optical tape recorder with ICI 1012 write-once optical tape media. Flexible optical media offers many benefits in terms of manufacture; for a given capital investment, continuous, web-coating techniques produce more square meters of media than batch coating. The coated layers consist of a backcoat on the non-active side; on the active side there is a subbing layer, then reflector, dye/polymer, and transparent protective overcoat. All these layers have been tailored for ease of manufacture and specific functional characteristics.

  14. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 1 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 1 through 3. The activities from other flight days can be seen on 'STS 109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), 'STS 109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139471), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). The main activity recorded during flight day 1 is the liftoff of Columbia. Attention is given to suit-up, boarding, and pre-flight procedures. The pre-launch crew meal has no sound. The crew members often wave to the camera before liftoff. The jettisoning of the solid rocket boosters is shown, and the External Tank is seen as it falls to Earth, moving over African dunes in the background. There are liftoff replays, including one from inside the cockpit. The opening of the payload bay doors is seen from the rear of the shuttle's cockpit. The footage from flight day 2 shows the Flight Support System for bearthing the HST (Hubble Space Telescope). Crew preparations for the bearthing are shown. Flight day 3 shows the tracking of and approach to the HST by Columbia, including orbital maneuvers, the capture of the HST, and its lowering onto the Flight Support System. Many views of the HST are shown, including one which reveals an ocean and cloud background as the HST retracts a solar array.

  15. Matched-pair analyses of resting and dynamic morphology between Monarc and TVT-O procedures by ultrasound.

    PubMed

    Yang, Jenn-Ming; Yang, Shwu-Huey; Huang, Wen-Chen; Tzeng, Chii-Ruey

    2013-07-01

    To determine morphologic differences between Monarc and TVT-O procedures in axial and coronal planes by three- and four-dimensional (3D and 4D) ultrasound. Retrospective chart audits and ultrasound analyses were conducted on 128 women who had undergone either Monarc or TVT-O procedures for urodynamic stress incontinence. Thirty matched pairs of the two successful procedures were randomly selected and compared. Matched variables were age, parity, body mass index, cesarean status, menopausal status, and primary surgeries. Six-month postoperative 3D and 4D ultrasound results obtained at rest, on straining, and during coughing in these 60 women were analyzed. Assessed ultrasound parameters included the axial tape urethral distance (aTUD), axial central urethral echolucent area (aUCEA), axial tape angle (aTA), and coronal tape angle (cTA), all of which were measured at three equidistant points along the tapes. Paired t-tests were used to compare differences in ultrasound parameters between women after the two procedures and a P value <0.004 was considered significant after Bonferroni correction. At rest, women subjected to Monarc procedures had a significantly wider aTA at one-fourth of the tape and a wider cTA at one-, two-, and three-fourths of the tape than did those subjected to TVT-O procedures. There were no significant differences in other resting ultrasound parameters between these two procedures. Additionally, after both procedures women had comparable straining and coughing ultrasound manifestations as well as respective dynamic changes. Despite flatter resting tape angulations in women following Monarc procedures, both Monarc and TVT-O tapes had equivalent dynamic patterns and changes assessed by 4D ultrasound. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  16. The role of social closeness during tape stripping to facilitate skin barrier recovery: Preliminary findings.

    PubMed

    Robinson, Hayley; Ravikulan, Abhimati; Nater, Urs M; Skoluda, Nadine; Jarrett, Paul; Broadbent, Elizabeth

    2017-07-01

    Social support is known to reduce the negative effects of stress on health, but there is mixed evidence for the effects of social support on wound healing. This study aimed to investigate whether undergoing a task designed to promote social closeness with a fellow participant and being paired with that person during a tape-stripping procedure could reduce stress and improve skin barrier recovery compared to going through tape stripping alone. Seventy-two healthy adults were randomized to either a social closeness condition where participants completed a relationship-building task and tape stripping in pairs or a control condition where they completed tape stripping alone. Skin barrier recovery was measured using transepidermal water loss. Salivary cortisol and alpha-amylase were collected at four time points as markers of the endocrine and autonomic stress response. Social closeness had a beneficial effect on skin barrier recovery compared to the control condition, t(54) = 2.86, p = .006, r = .36. Social closeness significantly reduced self-reported stress. The effects of the intervention on skin barrier recovery were moderated by self-reported stress reduction (p = .035). There were no significant differences in cortisol between groups, but alpha-amylase increased significantly more from baseline to after tape stripping in the control group compared to the intervention group. This is the first study to show that social closeness with a person going through a similar unfamiliar procedure can positively influence wound healing. Future research needs to replicate these findings in other wound types and in clinical settings. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  17. An in-house Composix™-based pubovaginal sling trial for female stress urinary incontinence: Five-year comparative followup to tension-free and transobturator vaginal tapes

    PubMed Central

    Ben-Zvi, Tal; Moore, Katherine; Haidar, Nadim; Gregoire, Mireille

    2017-01-01

    Introduction We compared the efficacy of three slings in the long-term treatment of stress urinary incontinence (SUI): tension-free vaginal tape (TVT), vaginal tape-obturator (TVT-O), and an in-house two-layered polypropylene mesh with a submicronic polytetrafluoroethylene (Composix™). Our primary endpoint was the objective measurement of continence (24-hour pad test). Secondarily, we measured the satisfaction and complication rates. Methods This prospective, non-randomized study included 128 patients with SUI. Preoperative evaluation included medical history, physical exam, 24-hour pad test, Urinary Incontinence Quality of Life Scale (IQOL), FPSUND, and global satisfaction questionnaires. Patients were followed at one month postoperative, biannually for two years, and then annually for a total of five years. Followup visits included a focused questionnaire, physical exam, satisfaction questionnaire, 24-hour pad test, IQOL, and FPSUND questionnaires. Results Composix, TVT, and TVT-O groups included 60, 34, and 34 patients, respectively. No significant differences were found in baseline characteristics except for the pad test. Length of catheterization was the only immediate operative significant parameter (Composix 4.7 days vs. TVT 1.1 days vs. TVT-O 2.6 days; p=0.03). The entire cohort had significant improvements in their IQOL, FPSUND, and pad test at one and four years (p<0.01). The cohort-wide 24-hour pad test average weight was 30.4 g preoperatively vs. 5 g at 12 months (p<0.00001) (Composix 37 to 5 g, TVT 83 to 4 g, and TVT-O 55 to 5 g). The Composix group had a higher number of minor complications (Clavien I, II) and secondary procedures. Conclusions This single-surgeon cohort with five-year followup demonstrated a large improvement and maintenance of continence in all three surgical groups. The Composix-based sling provided comparable continence outcomes at a fraction of the cost; however, its increased morbidity and higher complication rate raise

  18. Health-related quality of life after maxillectomy: obturator rehabilitation compared with flap reconstruction.

    PubMed

    Breeze, J; Rennie, A; Morrison, A; Dawson, D; Tipper, J; Rehman, K; Grew, N; Snee, D; Pigadas, N

    2016-10-01

    Health-related quality of life (QoL) reported by patients has the potential to improve care after ablative surgery of the midface, as existing treatment algorithms still generally revolve around outcomes assessed traditionally only by clinicians. Decisions in particular relate to reconstruction with a flap compared with rehabilitation with an obturator, the need for adjuvant treatment, and morbidity related to the size of the defect. We prospectively collected health-related QoL assessments for 39 consecutive patients treated by maxillectomy between 01 January 2010 and 31 December 2014 using the University of Washington Quality of Life Questionnaire, and who had a mean (SD) duration of follow-up of 14 (4). We made sub-group analyses using paired t tests and analysis of variance (ANOVA) to compare reconstruction with a flap with rehabilitation with obturators, size of the vertical defect, and whether adjuvant treatment with radiotherapy or chemoradiotherapy adversely affected it. Overall there was a significant decrease in health-related QoL after treatment compared with before (p<0.001), but there was no significant difference in the effects of any of the paired reconstructive and rehabilitation treatments on it. Obturators remain an important option for rehabilitation in selected patients in addition to reconstruction with a flap. We found that neither increasing the size of the vertical defect (in an attempt to ensure clear margins) nor the use of postoperative radiotherapy seemed to have any adverse effect on QoL. More patients are required before we can conclude that the potential survival benefits of such measures may outweigh any adverse effects. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  19. Pathogenesis and Treatment of Cerebral Air Embolism and Associated Disorders.

    DTIC Science & Technology

    1984-04-01

    blades) 12. 7.0, 8.0 and 9.0-mm endotracheal tubes 13. Endotracheal tube stylet 14. Esophageal obturator airway 15. Tracheal suction catheters (14F) 17 r...16. Nasogastric suction tube and Tumee syringe 17. Tincture of Benzoin 18. 2-in waterproof tape 19. Precordial stethoscope 20. Esophageal stethoscope...be justified. If an endotracheal tube cannot be passed, an esophageal obturator airway may be useful. If such an airway Is used, the newer models

  20. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, Eric B.; Muller, Albert C.

    1984-01-01

    A high voltage oil-impregnated electrical cable with fully polymer taped insulation operable to 765 kV. Biaxially oriented, specially processed, polyethylene, polybutene or polypropylene tape with an embossed pattern is wound in multiple layers over a conductive core with a permeable screen around the insulation. Conventional oil which closely matches the dielectric constant of the tape is used, and the cable can be impregnated after field installation because of its excellent impregnation characteristics.

  1. Kinematics of Tape Recording.

    ERIC Educational Resources Information Center

    Coleman, J. J.

    1982-01-01

    Describes mathematics of the nonliner relationships between a constant-speed, capstan-driven magnetic tape transport mechanism and a constant-angular-velocity take-up reel. The relationship, derived from the sum of a partial, serves in recognition of a finite tape. Thickness can serve as an example of rotational kinematics. (Author/SK)

  2. Light-Curing Adhesive Repair Tapes

    NASA Technical Reports Server (NTRS)

    Allred, Ronald; Haight, Andrea Hoyt

    2009-01-01

    Adhesive tapes, the adhesive resins of which can be cured (and thereby rigidized) by exposure to ultraviolet and/or visible light, are being developed as repair patch materials. The tapes, including their resin components, consist entirely of solid, low-outgassing, nonhazardous or minimally hazardous materials. They can be used in air or in vacuum and can be cured rapidly, even at temperatures as low as -20 C. Although these tapes were originally intended for use in repairing structures in outer space, they can also be used on Earth for quickly repairing a wide variety of structures. They can be expected to be especially useful in situations in which it is necessary to rigidize tapes after wrapping them around or pressing them onto the parts to be repaired.

  3. Obturator internus pyomyositis manifested as sciatica in a patient with subacute bacterial endocarditis: A rare case report.

    PubMed

    Hsu, Wei-Ching; Hsu, Jin-Yi; Chen, Michael Yu-Chih; Liang, Chung-Chao

    2016-07-01

    Pyomyositis is a pyogenic infection of the skeletal muscles causing myalgia and fever in patients. Hematogenous seeding engendered by persistent bacteremia and septic embolism is usually the underlying cause of the disease. Trauma, intravenous drug use, and immunodeficiency are the main predisposing factors.Obturator internus pyomyositis with sciatica has not previously been reported. We report a rare case of a patient with subacute bacterial endocarditis presenting with left buttock pain and sciatica.Computed tomography confirmed the diagnosis of obturator internus pyomyositis. The patient was discharged uneventfully after successful antibiotic treatment.The mortality rate of patients who have pyomyositis comorbid with another condition or disease is extremely high. Early diagnosis and aggressive management are imperative.

  4. FGGE/ERBZ tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The FGGE/ERBZ tape contains 5 parameters which are extracted and reformatted from the Nimbus-7 ERB Zonal Means Tape. There are three types of files on a FGGE/ERBZ tape: a tape header file, and data files. Physical characteristics, gross format, and file specifications are given. A sample tape check/document printout (shipping letter) is included.

  5. FGGE/ERBM tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The Nimbus-7 FGGE/ERBM tape contains 27 ERB parameters which are extracted and reformatted from the Nimbus-7 ERB-MATRIX tape. There are four types of files on a FGGE/ERBM tape: a test file; tape-header file which describes the data set characteristics and the contents of the tape; a grid-descriptor file which contains the information of the ERB scanning channel target number and their associated latitude limits and longitude intervals; and one or more data files. A single end-of-file (EOF) tape mark is written after each file, and two EOF marks are written after the last data file on the tape.

  6. Comparison between three mini-sling surgical procedures and the traditional transobturator vaginal tape technique for female stress urinary incontinence

    PubMed Central

    LEANZA, V.; INTAGLIATA, E.; LEANZA, A.; FERLA, F.; LEANZA, G.; VECCHIO, R.

    2014-01-01

    Objectives To compare mini-sling and traditional tension-free operations for female stress urinary incontinence. Study design A systematic review of articles in the Literature published between 2002 and 2012, was conducted. A Pubmed search was performed. Primary outcomes were subjective and objective cure rates at 12 months comparing the three single-incision mini-slings techniques (TVT-Secur, MiniArc and Monarc systems) with the standard mid-urethral sling procedure TOT (Transobturator Vaginal Tape). Secondary outcomes included peri-operative (vaginal and/or bladder perforation, urine retention, urinary tract infection, bleeding, pain) and post-operative (mesh exposure, de novo urgency, and dyspareunia) complications. Results In term of objective cure rate at 12 month after surgery, it is evident that TOT at first, and MiniArc are the most effective procedures. The incidence of post-operative urgency and UTI was lower in TOT technique, while vaginal perforation was described in equal frequency both in TOT and in MiniArc procedures. The advantages of the three above described mini-invasive techniques seem to consist into lower cases of urinary retention, pain and bleeding. Furthermore, bladder perforation and bleeding are not described in the Literature for TVT-Secur and Monarc systems. Conclusions Some single-incision slings look promising and as effective as conventional sub-urethral slings at short term evaluation. However, at this moment a clear statement in favor of the widespread use of single-incision slings cannot be made. More studies must define the efficacy of these techniques. PMID:24841685

  7. Caught (Unfortunately) on Tape

    ERIC Educational Resources Information Center

    Young, Jeffrey R.

    2009-01-01

    Recording class sessions so students can view them online is becoming routine on many campuses. But all that taping can lead to "uh-oh moments," such as when a professor's joke about the college dean ends up on YouTube, or a private comment to a student after class is inadvertently broadcast. Some lecture bloopers caught on tape are…

  8. Effectiveness of functional ankle taping for judo athletes: a comparison between judo bandaging and taping.

    PubMed Central

    Yamamoto, T; Kigawa, A; Xu, T

    1993-01-01

    This study was conducted to compare the effectiveness of the traditional method of ankle bandaging and the new method of ankle taping for judo athletes in Japan, and to introduce a functionally effective taping method for judo players. Four university judo athletes with ankle instability were selected to undertake radiography of the ankles before and after exercise, with bandaging at one time and taping at the other. Talar tilt (TT) angles were measured in order to compare the ankle-supporting effects. The results showed that the old ankle bandaging method had no role in eliminating the talar tilt during judo practice. In contrast, the new taping method was more effective in eliminating the talar tilt and supporting the involved ankles both mechanically and functionally. Images Figure 1 Figure 2 Figure 3 PMID:8358580

  9. TVT-S in the U position--anatomical study.

    PubMed

    Hubka, Petr; Nanka, Ondrej; Martan, Alois; Grim, Milos; Zvarova, Jana; Masata, Jaromir

    2011-02-01

    The objective is to describe the anatomical position of tension-free vaginal tape Secur (TVT-S) in the U position regarding possible injury and fixation site. We placed TVT-S inserters bilaterally in 13 embalmed and five fresh frozen female bodies. After dissection, we measured distances from the obturator bundle. In embalmed bodies, the mean distance of TVT-S from the obturator bundle was 2.83 cm (standard deviation (SD) 0.87 cm) on the left, 2.92 cm (SD 1.24 cm) on the right. Perforation of the fascia of obturator internus muscle occurred in 38.5%. In fresh frozen bodies, results were fundamentally similar (p > 0.05). There is a risk of injury to the obturator bundle and urinary bladder during TVT-S; however, there is a significant risk of inserting the TVT-S inserter outside the obturator internus muscle (into the lesser pelvis). The position of TVT-S does not change significantly after legs mal-positioning.

  10. Immediate Effects of Ankle Balance Taping with Kinesiology Tape for Amateur Soccer Players with Lateral Ankle Sprain: A Randomized Cross-Over Design

    PubMed Central

    Kim, Myoung Kwon; Shin, Young Jun

    2017-01-01

    Background The objective of this study was to investigate the immediate effect on gait function when ankle balance taping is applied to amateur soccer players with lateral ankle sprain. Material/Methods A cross-over randomized design was used. Twenty-two soccer players with an ankle sprain underwent 3 interventions in a random order. Subjects were randomly assigned to ankle balance taping, placebo taping, and no taping groups. The assessment was performed using the GAITRite portable walkway system, which records the location and timing of each footfall during ambulation. Results Significant differences were found in the velocity, step length, stride length, and H-H base support among the 3 different taping methods (p<0.05). The ankle balance taping group showed significantly greater velocity, step length, and stride length in comparison to the placebo and no taping group. The ankle balance taping group showed a statistically significant decrease (p<0.05) in the H-H base support compared to the placebo and no taping groups, and the placebo group showed significantly greater velocity in comparison to the no taping group (p<0.05). Conclusions We conclude that ankle balance taping that uses kinesiology tape instantly increased the walking ability of amateur soccer players with lateral ankle sprain. Therefore, ankle balance taping is a useful alternative to prevent and treat ankle sprain of soccer players. PMID:29158472

  11. The TVT Worldwide Observational Registry for Long-Term Data: safety and efficacy of suburethral sling insertion approaches for stress urinary incontinence in women.

    PubMed

    Tincello, Douglas G; Botha, Theunis; Grier, Douglas; Jones, Peter; Subramanian, Dhinagar; Urquhart, Colin; Kirkemo, Aaron; Khandwala, Salil

    2011-12-01

    We examined the clinical effectiveness of a single incision sling in women with stress urinary incontinence and obtained comparative perioperative and postoperative data on retropubic and transobturator slings. Women who underwent a cough stress test were treated with surgery using a single incision, retropubic or obturator sling (Gynecare® TVT SECUR™, TVT™ or TVT Obturator System, respectively) with the choice of sling based on surgeon preference. Objective cure was assessed by the standing cough stress test at 1 year. Subjective outcomes were assessed by the Incontinence Quality of Life Questionnaire and EQ-5D™. Perioperative data and return to normal activity were recorded. Of the 1,398 women who underwent surgery there were postoperative data on 1,334, including 32.8%, 17.8% and 49.4% who received a tension free vaginal tape, obturator tension free vaginal tape and SECUR, respectively. After obturator tension free vaginal tape surgery fewer women had a positive cough stress test than after TVT and SECUR surgery (4 of 110 or 3.6% vs 24 of 187 or 12.8% and 59 of 374 or 15.8%, respectively). Incontinence Quality of Life Questionnaire effect size was 1.87, 1.42 and 1.56, respectively, indicating a large treatment effect. Using our Incontinence Quality of Life Questionnaire response definition 85.4%, 79.0% and 85.2% of the TVT, TVT outside-in obturator system and SECUR cohorts, respectively, were treatment responders (p = 0.11).The SECUR cohort had the shortest operative time, the lowest proportion of women who required an overnight stay and the most women who underwent surgery under local anesthesia. Median time to return to employment, housework, sex life and hobbies was most rapid for SECUR. This registry demonstrates the high effectiveness of all 3 approaches. The single incision sling appeared to have objective and subjective efficacy similar to that of the retropubic sling and it can be performed under local anesthesia in an office environment

  12. High density tape/head interface study

    NASA Technical Reports Server (NTRS)

    Csengery, L. C.

    1983-01-01

    The high energy (H sub c approximately or = to 650 oersteds) tapes and high track density (84 tracks per inch) heads investigated had, as its goal, the definition of optimum combinations of head and tape, including the control required of their interfacial dynamics that would enable the manufacture of high rate (150 Mbps) digital tape recorders for unattended space flight.

  13. A prospective randomized blister prevention trial assessing paper tape in endurance distances (Pre-TAPED).

    PubMed

    Lipman, Grant S; Ellis, Mark A; Lewis, Erica J; Waite, Brandee L; Lissoway, John; Chan, Garrett K; Krabak, Brian J

    2014-12-01

    Friction foot blisters are a common injury occurring in up to 39% of marathoners, the most common injury in adventure racing, and represent more than 70% of medical visits in multi-stage ultramarathons. The goal of the study was to determine whether paper tape could prevent foot blisters in ultramarathon runners. This prospective randomized trial was undertaken during RacingThePlanet 155-mile (250-km), 7-day self-supported ultramarathons in China, Australia, Egypt, Chile, and Nepal in 2010 and 2011. Paper tape was applied prerace to one randomly selected foot, with the untreated foot acting as the own control. The study end point was development of a hot spot or blister on any location of either foot. One hundred thirty-six participants were enrolled with 90 (66%) having completed data for analysis. There were 36% women, with a mean age of 40 ± 9.4 years (range, 25-40 years) and pack weight of 11 ± 1.8 kg (range, 8-16 kg). All participants developed blisters, with 89% occurring by day 2 and 59% located on the toes. No protective effect was observed by the intervention (47 versus 35; 52% versus 39%; P = .22), with fewer blisters occurring around the tape on the experimental foot than under the tape (23 vs 31; 25.6% versus 34.4%), yet 84% of study participants when queried would choose paper tape for blister prevention in the future. Although paper tape was not found to be significantly protective against blisters, the intervention was well tolerated with high user satisfaction. Copyright © 2014 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  14. Design and implementation of scalable tape archiver

    NASA Technical Reports Server (NTRS)

    Nemoto, Toshihiro; Kitsuregawa, Masaru; Takagi, Mikio

    1996-01-01

    In order to reduce costs, computer manufacturers try to use commodity parts as much as possible. Mainframes using proprietary processors are being replaced by high performance RISC microprocessor-based workstations, which are further being replaced by the commodity microprocessor used in personal computers. Highly reliable disks for mainframes are also being replaced by disk arrays, which are complexes of disk drives. In this paper we try to clarify the feasibility of a large scale tertiary storage system composed of 8-mm tape archivers utilizing robotics. In the near future, the 8-mm tape archiver will be widely used and become a commodity part, since recent rapid growth of multimedia applications requires much larger storage than disk drives can provide. We designed a scalable tape archiver which connects as many 8-mm tape archivers (element archivers) as possible. In the scalable archiver, robotics can exchange a cassette tape between two adjacent element archivers mechanically. Thus, we can build a large scalable archiver inexpensively. In addition, a sophisticated migration mechanism distributes frequently accessed tapes (hot tapes) evenly among all of the element archivers, which improves the throughput considerably. Even with the failures of some tape drives, the system dynamically redistributes hot tapes to the other element archivers which have live tape drives. Several kinds of specially tailored huge archivers are on the market, however, the 8-mm tape scalable archiver could replace them. To maintain high performance in spite of high access locality when a large number of archivers are attached to the scalable archiver, it is necessary to scatter frequently accessed cassettes among the element archivers and to use the tape drives efficiently. For this purpose, we introduce two cassette migration algorithms, foreground migration and background migration. Background migration transfers cassettes between element archivers to redistribute frequently accessed

  15. Structural modeling of HTS tapes and cables

    NASA Astrophysics Data System (ADS)

    Allen, N. C.; Chiesa, L.; Takayasu, M.

    2016-12-01

    Structural finite element analysis (FEA) has been used as an insightful tool to investigate the electromechanical behavior of HTS REBCO tapes and twisted stacked-tape cables under tension, torsion, bending and combined loads. A novel technique was developed for modeling the layered composite structure of the 2G tapes with structural solid-shell elements in ANSYS®. The FEA models produced detailed strain information for the REBCO superconducting layer which was then paired with an analytical model to predict the critical current performance of the 2G HTS tapes under various loads. Two commercially available HTS tapes (SuperPower and SuNAM) under tension, torsion and combined tension-torsion were first analyzed with FEA and compared with available experimental results at 77 K. A sharp critical current degradation was experienced at the yield strength of the tapes under tension and below a 100 mm twist-pitch under torsion. Combined tension-torsion loads had a more gradual degradation of critical current for twist-pitches of 115 mm or shorter but had a negligible difference compared to pure tension for longer twist-pitches. Using the structural solid-shell technique for modeling 2G tapes in ANSYS®, an FEA methodology for simulating full scale three-dimensional HTS stacked-tape cables under pure bending was created. A model of a Twisted-Stacked Tape Cable (TSTC), a configuration first proposed at MIT, was initially developed and then adapted to the slotted-core HTS Cable-In-Conduit Conductor produced by the ENEA laboratory in Italy. The numerical axial strain of the HTS REBCO tapes within the cables as calculated by FEA were found to agree with an analytical model for two cases: perfect-slip (frictionless) and no-slip (bonded). The ENEA CICC model was also compared with recent experimental critical current data at 77 K and was found to match best using a low friction coefficient of 0.02 indicating that the tapes within the cable freely slide with respect to each other

  16. Comparison of post-obturation pain experience following one-visit and two-visit root canal treatment on teeth with vital pulps: a randomized controlled trial.

    PubMed

    Wang, C; Xu, P; Ren, L; Dong, G; Ye, L

    2010-08-01

    To compare the incidence and intensity of post-obturation pain after one- or two-visit root canal treatment (RCT) on anterior teeth with vital pulps and a single root and canal in a randomized controlled trial. One hundred patients requiring RCT on permanent anterior teeth with vital pulps preoperatively were included. The patients were assigned randomly into two groups of 50 patients each. After local anaesthesia, isolation, access and pulp extirpation, the canals of all teeth were prepared using engine-driven rotary ProTaper nickel-titanium instruments in a crown-down technique and irrigated with 2.5% NaOCl. The teeth in group 1 (n = 50) were filled with AH Plus sealer and gutta-percha using a lateral compaction technique at the first visit, whilst those in group 2 (n = 50) were medicated with a calcium hydroxide paste, a sterile dry cotton pellet and Caviton and scheduled for a second visit 7 days later. A modified verbal descriptor scale was used to measure preoperative pain and post-obturation pain at 6, 24, 48 h and 1 week after operation. Chi-square tests and independent-sample T-tests were used to compare the incidence and intensity of post-obturation pain of two groups at each interval. Eleven patients were excluded from the study as they failed to follow the scheduled revisit or their selected teeth had more than one root canal. Data were obtained from the remaining 89 patients. Forty-three patients were undergoing one-visit treatment (group 1) and 46 undergoing two-visit treatment (group 2). Most patients in both groups reported no pain or only slight pain within each post-obturation interval, only one in group 1 and one in group 2 had flare-ups and slight swelling. There was no statistically significant difference in the incidence and intensity of post-obturation pain experienced by two groups. The incidence and intensity of post-obturation pain experience following one- or two-visit RCT on teeth with vital pulps and a single canal were not

  17. Micro-Teaching Tapes in Anatomy and Physiology.

    ERIC Educational Resources Information Center

    Stencel, John E.

    1981-01-01

    Outlines the development and use of micro-teaching tapes as a means of supplemental instruction for college anatomy and physiology classes. Tapes include brief explanations of difficult concepts taken from lectures as students listen to cassette tapes and fill in blanks, or answer questions. (DS)

  18. Strategy for robot motion and path planning in robot taping

    NASA Astrophysics Data System (ADS)

    Yuan, Qilong; Chen, I.-Ming; Lembono, Teguh Santoso; Landén, Simon Nelson; Malmgren, Victor

    2016-06-01

    Covering objects with masking tapes is a common process for surface protection in processes like spray painting, plasma spraying, shot peening, etc. Manual taping is tedious and takes a lot of effort of the workers. The taping process is a special process which requires correct surface covering strategy and proper attachment of the masking tape for an efficient surface protection. We have introduced an automatic robot taping system consisting of a robot manipulator, a rotating platform, a 3D scanner and specially designed taping end-effectors. This paper mainly talks about the surface covering strategies for different classes of geometries. The methods and corresponding taping tools are introduced for taping of following classes of surfaces: Cylindrical/extended surfaces, freeform surfaces with no grooves, surfaces with grooves, and rotational symmetrical surfaces. A collision avoidance algorithm is introduced for the robot taping manipulation. With further improvements on segmenting surfaces of taping parts and tape cutting mechanisms, such taping solution with the taping tool and the taping methodology can be combined as a very useful and practical taping package to assist humans in this tedious and time costly work.

  19. Three-dimensional finite element analysis of the application of attachment for obturator framework in unilateral maxillary defect.

    PubMed

    Sun, J; Jiao, T; Tie, Y; Wang, D-M

    2008-09-01

    The aim of this study was to evaluate the stress on the abutment teeth and framework ina unilateral maxillary defect which was restored by an obturator retained by resin-bonded extra coronal attachment. A three-dimensional finite element model of the human unilateral maxillary defect was constructed. Traditional obturator framework with four casting circumferential clasp was established (model 1). A continuous lingual guide plane of 0.5 mm thickness on all of the remaining teeth, with Mini-SG/F attachment on the mesial surface of the central incisor was also established (model 2). The modelling and analytical processes were performed using the ANSYS technologies. Stress was transmitted to the anterior part of the palate, with stress values being lower on the anterior teeth compared with the posteriors. The highest stress value of model 1 and model 2 was 13.1 Mpa, 19.9 Mpa respectively. Stress concentrations were found at the junction of the attachment to the lingual guide plane and the anterior part of the lingual plane. The results of this study suggest that the application of a resin-bonded extra coronal attachment for obturator retention is in accordance with the design principles for the restorative treatment of maxillary defects.The design of the attachment framework needs to be further investigated. Benefit can be gained by splinting the abutment teeth.

  20. Chemical News Via Audio Tapes: Chemical Industry News

    ERIC Educational Resources Information Center

    Hanford, W. E.; And Others

    1972-01-01

    Tape coverage of internal R&D news now has a broader scope with improved features. A new tape series covering external news of broad interest has been initiated. The use of tape in a Continuing Education Program is discussed as the future plans for expanding the audio tape program. (1 reference) (Author)

  1. Failure and fatigue characteristics of adhesive athletic tape.

    PubMed

    Bragg, Richard W; Macmahon, John M; Overom, Erin K; Yerby, Scott A; Matheson, Gordon O; Carter, Dennis R; Andriacchi, Thomas P

    2002-03-01

    Athletic tape has been commonly reported to lose much of its structural support after 20 min of exercise. Although many studies have addressed the functional performance characteristics of athletic tape, its mechanical properties are poorly understood. This study examines the failure and fatigue properties of several commonly used athletic tapes. A Web-based survey of professional sports trainers was used to select the following three tapes for the study: Zonas (Johnson & Johnson), Leukotape (Beiersdorf), and Jaylastic (Jaybird & Mais). Using a hydraulic material testing system (MTS), eight samples of each tape were compared in three different mechanical tests: load-to-failure, fatigue testing under load control, and fatigue testing under displacement control. Differences in tape microstructure were used to interpret the results of the mechanical tests. Significant differences (P < 0.001) in failure load, elongation at failure, and stiffness were found from failure tests. Significant differences were also found (P < 0.001) in fatigue behavior under both modes of control. As a representative example, in one normalized displacement control fatigue test after 20 min of cycling, 21% (Zonas), 29% (Leukotape), and 57% (Jaylastic) of the mechanical support was lost. After cycling, all tapes loaded to failure showed increased stiffness (P < 0.001), indicating significant energy absorption during cycling. Observed differences in the tapes' microstructure were qualitatively consistent with the measured differences in their mechanical properties. In understanding the shortcomings of currently available tapes, the results of these tests can now be used as benchmarks with which to compare and develop future tape designs. Ultimately, these improved tapes should reduce ankle injuries among athletes.

  2. Tape-cast sensors and method of making

    DOEpatents

    Mukundan, Rangachary [Santa Fe, NM; Brosha, Eric L [Los Alamos, NM; Garzon, Fernando H [Santa Fe, NM

    2009-08-18

    A method of making electrochemical sensors in which an electrolyte material is cast into a tape. Prefabricated electrodes are then partially embedded between two wet layers of the electrolyte tape to form a green sensor, and the green sensor is then heated to sinter the electrolyte tape around the electrodes. The resulting sensors can be used in applications such as, but not limited to, combustion control, environmental monitoring, and explosive detection. A electrochemical sensor formed by the tape-casting method is also disclosed.

  3. Influence of different operating conditions on irrigation uniformity with microperforated tapes

    NASA Astrophysics Data System (ADS)

    Moreno Pizani, María Alejandra; Jesús Farías Ramírez, Asdrúbal

    2013-04-01

    Irrigated agriculture is a safe alternative to meet the growing demand for food. Numerous studies show that proper management of localized irrigation can increase crop yields and reduce soil salinization. Therefore, periodic field systems irrigation assessments are needed in order to optimize the use efficiency of irrigation water, as well as, to increase the agricultural area covered by the same amount of water and to reduce the environmental impact. It was assessed the behavior of micro perforated tapes under different operating conditions, crops and regions of Venezuela. Evaluations were made on irrigated areas using Santeno ® Type I tape with the following crops: Banana (Musa sp), lettuce (Lactuca sativa L.), carrot (Daucus carota L) and forage sugar cane (Saccharum officinarum). In the other hand, Santeno ® Type II tape was used with papaya (Carica papaya L.) and melon (Cucumis melo L.) crops (the last crop using inverted irrigation tape). The procedures used for sampling and determining the uniformity indices of the system were performed using a series of adjustments to the methodology proposed by Keller and Karmeli (1975), Deniculi (1980) and De Santa and De Juan (1993), in order to increase the number of observations as a function of irrigation time. The calculated irrigation uniformity indices were as follow: Distribution Coefficient (UD), Uniformity Coefficient (CUC), Coefficient of Variation of Flows (CV) and Statistical Uniformity Coefficient (Us). The indices characterization was made according to Merrian and Keller (1978); Bralts (1986); Pizarro (1990) y ASAE (1996), respectively. The results showed that the irrigation uniformity for the evaluated systems varied from excellent to unacceptable, mainly due to the lack of maintenance and the absent of manometric connectors. Among the findings, it is possible to highlight the need for technical support to farmers, both in the installation, management and maintenance of irrigation systems. In this sense

  4. Long-term clinical outcomes with the retropubic tension-free vaginal tape (TVT) procedure compared to Burch colposuspension for correcting stress urinary incontinence (SUI).

    PubMed

    Holdø, Bjørn; Verelst, Margareta; Svenningsen, Rune; Milsom, Ian; Skjeldestad, Finn Egil

    2017-11-01

    The retropubic tension-free vaginal tape (TVT) procedure replaced Burch colposuspension as the primary surgical method for stress urinary incontinence (SUI) and mixed urinary incontinence (MUI) in women in our department in 1998. In this study we compared the short-term and long-term clinical outcomes of these surgical procedures. Using a case series design, we compared the last 5 years of the Burch procedure (n = 127, 1994-1999) with the first 5 years of the retropubic TVT procedure (n = 180, 1998-2002). Information from the medical records was transferred to a case report form comprising data on perioperative and long-term complications as well as recurrence of UI, defined as bothersome UI or UI in need of repeat surgery. Other endpoints were rates of perioperative and late complications and the rates of prolapse surgery after primary surgery. The data were analyzed with the chi-squared and t tests and survival analysis using SPSS. The cumulative recurrence rate of SUI in women with preoperative SUI was significantly higher after the Burch procedure, but no difference was observed in women with MUI. There were no significant differences in rates of perioperative and late complications. At 12 years there was a significant increase in rates of repeat surgery for incontinence and prolapse in women after the Burch procedure. The long-term efficacy of TVT surgery was superior to that of Burch colposuspension in women with SUI. In addition, the rate of late prolapse surgery was significantly higher after the Burch procedure.

  5. Nimbus-7 ERB Solar Analysis Tape (ESAT) user's guide

    NASA Technical Reports Server (NTRS)

    Major, Eugene; Hickey, John R.; Kyle, H. Lee; Alton, Bradley M.; Vallette, Brenda J.

    1988-01-01

    Seven years and five months of Nimbus-7 Earth Radiation Budget (ERB) solar data are available on a single ERB Solar Analysis Tape (ESAT). The period covered is November 16, 1978 through March 31, 1986. The Nimbus-7 satellite performs approximately 14 orbits per day and the ERB solar telescope observes the sun once per orbit as the satellite crosses the southern terminator. The solar data were carefully calibrated and screened. Orbital and daily mean values are given for the total solar irradiance plus other spectral intervals (10 solar channels in all). In addition, selected solar activity indicators are included on the ESAT. The ESAT User's Guide is an update of the previous ESAT User's Guide (NASA TM 86143) and includes more detailed information on the solar data calibration, screening procedures, updated solar data plots, and applications to solar variability. Details of the tape format, including source code to access ESAT, are included.

  6. Wire and Packing Tape Sandwiches

    ERIC Educational Resources Information Center

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  7. Reel-to-reel substrate tape polishing system

    DOEpatents

    Selvamanickam, Venkat; Gardner, Michael T.; Judd, Raymond D.; Weloth, Martin; Qiao, Yunfei

    2005-06-21

    Disclosed is a reel-to-reel single-pass mechanical polishing system (100) suitable for polishing long lengths of metal substrate tape (124) used in the manufacture of high-temperature superconductor (HTS) coated tape, including multiple instantiations of a polishing station (114) in combination with a subsequent rinsing station (116) arranged along the axis of the metal substrate tape (124) that is translating between a payout spool (110a) and a take-up spool (110b). The metal substrate tape obtains a surface smoothness that is suitable for the subsequent deposition of a buffer layer.

  8. Ubiquitous Graphene Electronics on Scotch Tape

    PubMed Central

    Chung, Yoonyoung; Ho Kim, Hyun; Lee, Sangryun; Lee, Eunho; Won Kim, Seong; Ryu, Seunghwa; Cho, Kilwon

    2015-01-01

    We report a novel concept of graphene transistors on Scotch tape for use in ubiquitous electronic systems. Unlike common plastic substrates such as polyimide and polyethylene terephthalate, the Scotch tape substrate is easily attached onto various objects such as banknotes, curved surfaces, and human skin, which implies potential applications wherein electronics can be placed in any desired position. Furthermore, the soft Scotch tape serves as an attractive substrate for flexible/foldable electronics that can be significantly bent, or even crumpled. We found that the adhesive layer of the tape with a relatively low shear modulus relaxes the strain when subjected to bending. The capacitance of the gate dielectric made of oxidized aluminum oxide was 1.5 μF cm−2, so that a supply voltage of only 2.5 V was sufficient to operate the devices. As-fabricated graphene transistors on Scotch tape exhibited high electron mobility of 1326 (±155) cm2 V−1 s−1; the transistors still showed high mobility of 1254 (±478) cm2 V−1 s−1 even after they were crumpled. PMID:26220874

  9. Technique for recovery of voice data from heat damaged magnetic tape

    NASA Technical Reports Server (NTRS)

    Melugin, J. F.; Obrien, D. E., III (Inventor)

    1974-01-01

    A method for conditioning, and thus enabling retrieval of intelligence from, magnetic tapes after damage from heat has caused the tape to wrinkle and curl severely thereby reducing tape width to less than one-half its original size. The damaged tape is superposed on a first piece of splicing tape with the oxide side of the magnetic tape in contact with the adhesive side of the splicing tape and then carefully smoothed by a special tool. A second piece of splicing tape is placed on the backing side of the magnetic tape then the resulting tape stack is trimmed to the original width of the magnetic tape. After the first piece of splicing tape is carefully removed from the oxide side of the damaged magnetic tape, the resulting magnetic tape is then ready to be placed into a recorder for playback.

  10. Crew procedures development techniques

    NASA Technical Reports Server (NTRS)

    Arbet, J. D.; Benbow, R. L.; Hawk, M. L.; Mangiaracina, A. A.; Mcgavern, J. L.; Spangler, M. C.

    1975-01-01

    The study developed requirements, designed, developed, checked out and demonstrated the Procedures Generation Program (PGP). The PGP is a digital computer program which provides a computerized means of developing flight crew procedures based on crew action in the shuttle procedures simulator. In addition, it provides a real time display of procedures, difference procedures, performance data and performance evaluation data. Reconstruction of displays is possible post-run. Data may be copied, stored on magnetic tape and transferred to the document processor for editing and documentation distribution.

  11. Paper Tape Prevents Foot Blisters: A Randomized Prevention Trial Assessing Paper Tape in Endurance Distances II (Pre-TAPED II).

    PubMed

    Lipman, Grant S; Sharp, Louis J; Christensen, Mark; Phillips, Caleb; DiTullio, Alexandra; Dalton, Andrew; Ng, Pearlly; Shangkuan, Jennifer; Shea, Katherine; Krabak, Brian J

    2016-09-01

    To determine whether paper tape prevents foot blisters in multistage ultramarathon runners. Multisite prospective randomized trial. The 2014 250-km (155-mile) 6-stage RacingThePlanet ultramarathons in Jordan, Gobi, Madagascar, and Atacama Deserts. One hundred twenty-eight participants were enrolled: 19 (15%) from the Jordan, 35 (27%) from Gobi, 21 (16%) from Madagascar, and 53 (41%) from the Atacama Desert. The mean age was 39.3 years (22-63) and body mass index was 24.2 kg/m (17.4-35.1), with 31 (22.5%) females. Paper tape was applied to a randomly selected foot before the race, either to participants' blister-prone areas or randomly selected location if there was no blister history, with untaped areas of the same foot used as the control. Development of a blister anywhere on the study foot. One hundred six (83%) participants developed 117 blisters, with treatment success in 98 (77%) runners. Paper tape reduced blisters by 40% (P < 0.01, 95% confidence interval, 28-52) with a number needed to treat of 1.31. Most of the study participants had 1 blister (78%), with most common locations on the toes (n = 58, 50%) and heel (n = 27, 23%), with 94 (80%) blisters occurring by the end of stage 2. Treatment success was associated with earlier stages [odds ratio (OR), 74.9, P < 0.01] and time spent running (OR, 0.66, P = 0.01). Paper tape was found to prevent both the incidence and frequency of foot blisters in runners.

  12. Comparative Evaluation of Sealing Ability of Three Newer Root Canal Obturating Materials Guttaflow, Resilon and Thermafil: An In Vitro Study

    PubMed Central

    H Bhandi, Shilpa; T S, Subhash

    2013-01-01

    Introduction: Microleakage continues to be a main reason for failure of root canal treatment where the challenge has been to achieve an adequate seal between the internal structure and the main obturating material. The objective of this study is to compare the sealing ability of 3 newer obturating materials GuttaFlow, Resilon/Epiphany system (RES) and Thermafil, using silver nitrate dye and observing under stereomicroscope. Methodology: Thirty single rooted teeth were divided into following groups. Group I : GuttaFlow ;Group II : Resilon /Epiphany sealer Group III : Thermafil with AH-Plus sealer. Teeth were decoronated and instrumented with profile rotary system and obturated with specified materials. Apical seal was determined by dye penetration method using silver nitrate. Then the specimens were transversely sectioned at each mm till 3 mm from the apex. Dye leakage was determined using stereomicroscope. Statistical analysis of the results was performed using Kruskall-Wallis test. Results: The results showed that Group II i.e., Resilon with Epiphany sealer showed the least amount of microleakage when compared to Group I i.e., GuttaFlow and Group III i.e., Thermafil with AH-plus sealer. Conclusion: Based on the results of this study it can be concluded that RES had higher sealing ability followed by Thermafil and GuttaFlow in vitro but further studies have to be carried out to make a direct correlation between these results and invivo situation. How to cite this article: Bhandi S H, Subhash T S. Comparative Evaluation of Sealing Ability of Three Newer Root Canal Obturating Materials Guttaflow, Resilon and Thermafil: An In Vitro Study. J Int Oral Health 2013; 5(1):54-65. PMID:24155579

  13. Digital methods of recording color television images on film tape

    NASA Astrophysics Data System (ADS)

    Krivitskaya, R. Y.; Semenov, V. M.

    1985-04-01

    Three methods are now available for recording color television images on film tape, directly or after appropriate finish of signal processing. Conventional recording of images from the screens of three kinescopes with synthetic crystal face plates is still most effective for high fidelity. This method was improved by digital preprocessing of brightness color-difference signal. Frame-by-frame storage of these signals in the memory in digital form is followed by gamma and aperture correction and electronic correction of crossover distortions in the color layers of the film with fixing in accordance with specific emulsion procedures. The newer method of recording color television images with line arrays of light-emitting diodes involves dichromic superposing mirrors and a movable scanning mirror. This method allows the use of standard movie cameras, simplifies interlacing-to-linewise conversion and the mechanical equipment, and lengthens exposure time while it shortens recording time. The latest image transform method requires an audio-video recorder, a memory disk, a digital computer, and a decoder. The 9-step procedure includes preprocessing the total color television signal with reduction of noise level and time errors, followed by frame frequency conversion and setting the number of lines. The total signal is then resolved into its brightness and color-difference components and phase errors and image blurring are also reduced. After extraction of R,G,B signals and colorimetric matching of TV camera and film tape, the simultaneous R,B, B signals are converted from interlacing to sequential triades of color-quotient frames with linewise scanning at triple frequency. Color-quotient signals are recorded with an electron beam on a smoothly moving black-and-white film tape under vacuum. While digital techniques improve the signal quality and simplify the control of processes, not requiring stabilization of circuits, image processing is still analog.

  14. Specification for wide channel bandwidth one-inch video tape

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1988-01-01

    Standards and controls are established for the procurement of wide channel bandwidth one inch video magnetic recording tapes for Very Long Base Interferometer (VLBI) system applications. The Magnetic Tape Certification Facility (MTCF) currently maintains three specifications for the Quality Products List (QPL) and acceptance testing of magnetic tapes. NASA-TM-79724 is used for the QPL and acceptance testing of new analog tapes; NASA-TM-80599 is used for QPL and acceptance testing of new digital tapes; and NASA-TM-100702 is used for the QPL and acceptance testing of new IBM/IBM compatible 3480 magnetic tape cartridges. This specification will be used for the QPL and acceptance testing of new wide channel bandwidth one inch video magnetic recording tapes. The one inch video tapes used by the Jet Propulsion Lab., the Deep Space Network and the Haystack Observatory will be covered by this specification. These NASA stations will use the video tapes for their VLBI system applications. The VLBI system is used for the tracking of quasars and the support of interplanetary exploration.

  15. [Iatrogenic risks during the obturation of the root canal system].

    PubMed

    Aesaert, G

    2000-01-01

    A hermetic seal is the main goal of obturation of the root canal system. For that purpose guttapercha still remains the filling material of choice. Most filling techniques use plasticized guttapercha and a condensation technique to fulfil the requirements of hermetic seal. The heat to plasticize and the forces applied to condense that material may have an influence on the periodontal ligament and/or the remaining tooth structure. Furthermore can overfilling of guttapercha and more likely the sealer, affect the periodontal tissue. Although rare, mandibular nerve damage and adverse effects on the sinus maxillaris can be the result of inadequate treatment.

  16. User's guide and tape specification for ERB 7 DELMAT

    NASA Technical Reports Server (NTRS)

    Ardanuy, P.; Penn, L.

    1985-01-01

    Guidance is provided to the DELMAT user in the areas of purpose, use and limitations of DELMAT tapes and software. The DELMAT tape specifications is also provided. The ERB-7, ERB MAT and tape characteristics applicable to the DELMAT tapes are also summarized.

  17. Nerve block of articular branches of the obturator and femoral nerves for the treatment of hip joint pain.

    PubMed

    Yavuz, Ferdi; Yasar, Evren; Ali Taskaynatan, Mehmet; Goktepe, Ahmet Salim; Tan, Arif Kenan

    2013-01-01

    The aim of this retrospective study was to investigate the effectiveness of the nerve block of articular branches of obturator and femoral nerves in patients with intractable pain due to hip osteoarthritis. Twenty patients (8 female and 12 male; with a mean age 53.5 years) were retrospectively identified who had received nerve block of articular branches of obturator and femoral nerves for chronic hip joint pain due to hip osteoarthritis. The outcome measures (visual analogue pain scale, the level of patient satisfaction with nerve block, reduction rate of NSAID using) were assessed before the treatment and at the 1st and 3rd months after injection. Mean reduction in hip joint pain while walking and at night between the baseline and 1st month, and between the baseline and 3rd month were statistically significant (p< 0.05). At the 1st and 3rd months after treatment, the reduction rates of NSAID using were almost 67% and 71%; respectively. At the 1st and 3rd months after treatment, the level of patient satisfaction with nerve block were 73.00 ± 21.23 mm and 73.50 ± 18.14 mm; respectively. We found that nerve blocks of articular branches of obturator and femoral nerves were effective in short- and mid-term for reducing chronic hip joint pain.

  18. Tape underlayment rotary-node (TURN) valves for simple on-chip microfluidic flow control

    PubMed Central

    Markov, Dmitry A.; Manuel, Steven; Shor, Leslie M.; Opalenik, Susan R.; Wikswo, John P.; Samson, Philip C.

    2013-01-01

    We describe a simple and reliable fabrication method for producing multiple, manually activated microfluidic control valves in polydimethylsiloxane (PDMS) devices. These screwdriver-actuated valves reside directly on the microfluidic chip and can provide both simple on/off operation as well as graded control of fluid flow. The fabrication procedure can be easily implemented in any soft lithography lab and requires only two specialized tools – a hot-glue gun and a machined brass mold. To facilitate use in multi-valve fluidic systems, the mold is designed to produce a linear tape that contains a series of plastic rotary nodes with small stainless steel machine screws that form individual valves which can be easily separated for applications when only single valves are required. The tape and its valves are placed on the surface of a partially cured thin PDMS microchannel device while the PDMS is still on the soft-lithographic master, with the master providing alignment marks for the tape. The tape is permanently affixed to the microchannel device by pouring an over-layer of PDMS, to form a full-thickness device with the tape as an enclosed underlayment. The advantages of these Tape Underlayment Rotary-Node (TURN) valves include parallel fabrication of multiple valves, low risk of damaging a microfluidic device during valve installation, high torque, elimination of stripped threads, the capabilities of TURN hydraulic actuators, and facile customization of TURN molds. We have utilized these valves to control microfluidic flow, to control the onset of molecular diffusion, and to manipulate channel connectivity. Practical applications of TURN valves include control of loading and chemokine release in chemotaxis assay devices, flow in microfluidic bioreactors, and channel connectivity in microfluidic devices intended to study competition and predator / prey relationships among microbes. PMID:19859812

  19. Magnetic Tape Recording

    NASA Technical Reports Server (NTRS)

    Athey, Skipwith W.

    1966-01-01

    NASA's contribution to tape recorder technology may appear to lie in such glamorous devices as the tape recorders of the Tiros and Nimbus satellites which receive signals carrying weather information during an orbit around the earth and then transmit those signals back to the ground when the satellite is in view of ground stations. These quite important recording devices are, however, only useful as members of a complex hierarchy of devices all of which participate in the ultimate process of obtaining information from NASA's efforts. Their existence and utility is based on the existence of many more prosaic recording devices which have been involved in the development of such spectacular units.

  20. An improved magnetic tape recorder

    NASA Technical Reports Server (NTRS)

    Uber, P. W.

    1968-01-01

    Magnetic tape recorder employs a single capstan for simultaneously driving the supply and take-up reels in such a manner that the tape passing between the reels is kept under a predetermined constant tension. This recorder operates with little power and is sufficiently rugged to withstand the severe stresses encountered in high-altitude balloon flight tests.

  1. A study of tape adhesive strength on endotracheal tubes.

    PubMed

    Fenje, N; Steward, D J

    1988-03-01

    A method of assessing the adhesive bond of tapes used to secure endotracheal (ET) tubes is described. Five kinds of tape and six different ET tubes including two silicone rubber, wire-reinforced tubes were tested. There are significant differences in the adhesive strength of different tapes, and in the adhesive bond formed by different ET tube materials. On the Portex clear ET tube, silk tape adhered best (p less than 0.001), followed by waterproof, cloth, dermiclear, and micropore tapes. Adhesive bonding by silk tape was significantly greater (p less than 0.001) for the three clear ET tubes (Portex clear, NCC clear, and Portex ivory) than for the Portex blue and the silicone rubber, wire-reinforced ET tubes. All tapes showed very poor or negligible adhesion to the Sheridan and Portex reinforced ET tubes. Adhesion to these tubes was greatly improved by wrapping them tightly with an "op site" dressing prior to applying tape.

  2. Tape SCSI monitoring and encryption at CERN

    NASA Astrophysics Data System (ADS)

    Laskaridis, Stefanos; Bahyl, V.; Cano, E.; Leduc, J.; Murray, S.; Cancio, G.; Kruse, D.

    2017-10-01

    CERN currently manages the largest data archive in the HEP domain; over 180PB of custodial data is archived across 7 enterprise tape libraries containing more than 25,000 tapes and using over 100 tape drives. Archival storage at this scale requires a leading edge monitoring infrastructure that acquires live and lifelong metrics from the hardware in order to assess and proactively identify potential drive and media level issues. In addition, protecting the privacy of sensitive archival data is becoming increasingly important and with it the need for a scalable, compute-efficient and cost-effective solution for data encryption. In this paper, we first describe the implementation of acquiring tape medium and drive related metrics reported by the SCSI interface and its integration with our monitoring system. We then address the incorporation of tape drive real-time encryption with dedicated drive hardware into the CASTOR [1] hierarchical mass storage system.

  3. Educational Uses of Cartridge Tapes. Dissemination Document No. 11.

    ERIC Educational Resources Information Center

    Levine, S. Joseph

    Tape cartridges for use by special education teachers are analyzed according to design, effective use, and availability. Basic operating principles of cassette and continuous loop tape cartridges are described and illustrated. Advantages of tape cartridges are indicated, such as the following: the position is saved on tape during student timeouts,…

  4. Methods and systems for fabricating high quality superconducting tapes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Majkic, Goran; Selvamanickam, Venkat

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  5. Hygrothermomechanical evaluation of transverse filament tape epoxy/polyester fiberglass composites

    NASA Technical Reports Server (NTRS)

    Lark, R. F.; Chamis, C. C.

    1984-01-01

    Transverse filament tape (TFT) fiberglass/epoxy and TFT polyester composites intended for low cost wind turbine blade fabrication have been subjected to static and cyclic load behavior tests whose results are presently evaluated on the basis of an integrated hygrothermomechanical response theory. Laminate testing employed simulated filament winding procedures. The results obtained show that the predicted hygrothermomechanical environmental effects on TFT composites are in good agreement with measured data for various properties, including fatigue at different R-ratio values.

  6. Certification of ICI 1012 optical data storage tape

    NASA Technical Reports Server (NTRS)

    Howell, J. M.

    1993-01-01

    ICI has developed a unique and novel method of certifying a Terabyte optical tape. The tape quality is guaranteed as a statistical upper limit on the probability of uncorrectable errors. This is called the Corrected Byte Error Rate or CBER. We developed this probabilistic method because of two reasons why error rate cannot be measured directly. Firstly, written data is indelible, so one cannot employ write/read tests such as used for magnetic tape. Secondly, the anticipated error rates need impractically large samples to measure accurately. For example, a rate of 1E-12 implies only one byte in error per tape. The archivability of ICI 1012 Data Storage Tape in general is well characterized and understood. Nevertheless, customers expect performance guarantees to be supported by test results on individual tapes. In particular, they need assurance that data is retrievable after decades in archive. This paper describes the mathematical basis, measurement apparatus and applicability of the certification method.

  7. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  8. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  9. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 5 2013-10-01 2013-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  10. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  11. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 5 2012-10-01 2012-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  12. To evaluate the influence of smear layer with different instruments and obturation methods on microleakage of root canal filled teeth: In vitro study.

    PubMed

    Likhitkar, Manoj S; Kulkarni, Shantaram V; Burande, Aravind; Solanke, Vishal; Kumar, C Sushil; Kamble, Babasaheb

    2016-01-01

    The success of root canal treatment depends on proper debridement, instrumentation, proper accessibility, and proper restoration. The presence of a smear layer is considered to be a significant factor. This in vitro study was conducted to assess the effect of the presence/absence of a smear layer on the microleakage of root canal filled teeth using different instruments and obturation methods. One hundred extracted mandibular premolars with closed apices and single roots were chosen and then divided into six groups, A to F, consisting of 15 teeth each. The control group included 10 teeth; 5 positive and 5 negative. The teeth were decoronated at the cementoenamel junction. Groups A, B, C, and D were instrumented with engine-driven rotary Protaper NiTi files. Groups E and F were instrumented with conventional stainless steel hand files. Groups A, C, and E were flushed with 3 ml of 17% EDTA to remove the smear layer prior to obturation. All teeth were flushed with 5.25% sodium hypochlorite solution and obturated with AH-Plus sealer with lateral condensation technique for Groups C, D, E, F and with thermoplasticized gutta-percha technique for Groups A and B. Using an electrochemical technique, leakages in the obturated canals were assessed for 45 days. The results were tabulated using Student's t-test (paired and unpaired t-test) with the Statistical Package for the Social Sciences Software Version 21 (IBM Company, New York, USA). Group A showed the lowest mean value at intervals of 10, 20, 30, and 45 days. There was no current flow in the negative controls during the test period. There was leakage in the positive controls within a few minutes of immersion. The results showed that rotary instrumentation contributed toward an exceptional preparation of root canals compared to hand instrumentation. Elimination of the smear layer enhanced the resistance to microleakage; thermoplasticized gutta-percha obturation technique produced a better seal compared to the lateral

  13. DICOM implementation on online tape library storage system

    NASA Astrophysics Data System (ADS)

    Komo, Darmadi; Dai, Hailei L.; Elghammer, David; Levine, Betty A.; Mun, Seong K.

    1998-07-01

    The main purpose of this project is to implement a Digital Image and Communications (DICOM) compliant online tape library system over the Internet. Once finished, the system will be used to store medical exams generated from U.S. ARMY Mobile ARMY Surgical Hospital (MASH) in Tuzla, Bosnia. A modified UC Davis implementation of DICOM storage class is used for this project. DICOM storage class user and provider are implemented as the system's interface to the Internet. The DICOM software provides flexible configuration options such as types of modalities and trusted remote DICOM hosts. Metadata is extracted from each exam and indexed in a relational database for query and retrieve purposes. The medical images are stored inside the Wolfcreek-9360 tape library system from StorageTek Corporation. The tape library system has nearline access to more than 1000 tapes. Each tape has a capacity of 800 megabytes making the total nearline tape access of around 1 terabyte. The tape library uses the Application Storage Manager (ASM) which provides cost-effective file management, storage, archival, and retrieval services. ASM automatically and transparently copies files from expensive magnetic disk to less expensive nearline tape library, and restores the files back when they are needed. The ASM also provides a crash recovery tool, which enable an entire file system restore in a short time. A graphical user interface (GUI) function is used to view the contents of the storage systems. This GUI also allows user to retrieve the stored exams and send the exams to anywhere on the Internet using DICOM protocols. With the integration of different components of the system, we have implemented a high capacity online tape library storage system that is flexible and easy to use. Using tape as an alternative storage media as opposed to the magnetic disk has the great potential of cost savings in terms of dollars per megabyte of storage. As this system matures, the Hospital Information Systems

  14. [Our experience with mini tapes (TVT Secur and MiniArc) in the surgery for stress urinary incontinence].

    PubMed

    Jiménez Calvo, J; Hualde Alfaro, A; Raigoso Ortega, O; Cebrian Lostal, J L; Alvarez Bandres, S; Jiménez Parra, J; Montesino Semper, M; Santiago Gonzalez de Garibay, A

    2008-01-01

    The purpose of this publication is to describe the surgical technique, assess complications and short-term results of TVT secur and MiniArc tapes. From October 2006 to August 2007 it was carried out the surgical correction with TVT Secur,Women's Health & Urology, Ethicon, Johnson & Johnson, placing the tape as a hammock, to 51 patients, 38 of them with pure stress incontinence and 13 with mixed incontinence and with an average age of 57 years. From September 2007 to February 2008 41 patients, 33 of them with pure stress incontinence and 8 with mixed incontinence, with an average of age of 58 years were operated with AMS Miniarc swing system tape, posted on hammock. All procedures were performed with sedoanalgesia and Ambulatory Surgery regime. Patients were monitored in outpatient visits one month, 3 months and one year after surgical procedure. Medical history and questionnaire and ICIQ-SF, to which we added a question to quantify the degree of satisfaction, as well as physical examination, were done. We compared the results of both technical procedures and statistical survey was conducted by Student test. [Analysis with SPSS software (V14.0)]. The median follow-up in TVT secur group was 328 days (range 163-522 days) and 101 days (range 41-209 days) inthe MiniArc group. We only had one (TVT secur group) surgical complication in all the series (92 patients) being a bladder perforation. Taking into account that we read a negative test effort as an objective cure in the TVT secur group, 80.4% patients are cured and 90.2% inthe MiniArc group without significant difference between both groups (p 0095). To assess the subjective healing we utilized the ICIQ-SF test and the satisfaction extra-question and we noted that there is no significant difference between the first and third month controls. (90% of patients satisfied). 80% of patients were completely satisfied in the first year control that was only performed to TVT secur group. These new tapes show fewer

  15. Penetrating Obturator Artery Injury after Gunshot Wounds: A Successful Multidisciplinary Trauma Team Approach to a Potentially Lethal Injury.

    PubMed

    Maraqa, Tareq I; Shin, Ji-Sun J; Diallo, Ismael; Sachwani-Daswani, Gul R; Mercer, Leo C

    2017-11-17

    Obturator artery injury (OAI) from pelvic gunshot wounds (GSW) is a rarely reported condition. Hemorrhages from pelvic trauma (PT) are mostly venous. Arterial hemorrhages represent about 10-20% of PTs. When arterial hemorrhages from PT occur, they are a severe and deadly complication often causing significant hemodynamic instability and eventual shock. A  23-year-old male presented to our emergency service via a private vehicle with multiple gunshot wounds to both thighs and to the lower back, resulted in rectal and obturator artery (OA) injuries. The patient underwent a successful coil-embolization of the right OA. Given the density of structures within the pelvis, patients who sustain gunshot wounds to the pelvic region are at high risk for injury to the small bowel, sigmoid colon, rectum, bladder, and/or vascular structures. While bleeding is the major cause of early mortality in PT, rectal injuries carry the highest mortality due to visceral injuries. A high clinical index of suspicion is needed to diagnose an iliac artery injury or injury to its branches. Prompt computed tomographic angiogram (CTA) and embolization of the OA is the best method to control and stop the bleeding and improve the mortality outcome. Clinicians caring for patients presenting with pelvic gunshot wounds should pay attention to the delayed presentation of internal hemorrhage from the OAs. A multidisciplinary team approach is crucial in the successful management of penetrating injuries to the obturator artery.

  16. Biomechanical 3-Dimensional Finite Element Analysis of Obturator Protheses Retained with Zygomatic and Dental Implants in Maxillary Defects

    PubMed Central

    Akay, Canan; Yaluğ, Suat

    2015-01-01

    Background The objective of this study was to investigate the stress distribution in the bone around zygomatic and dental implants for 3 different implant-retained obturator prostheses designs in a Aramany class IV maxillary defect using 3-dimensional finite element analysis (FEA). Material\\Methods A 3-dimensional finite element model of an Aramany class IV defect was created. Three different implant-retained obturator prostheses were modeled: model 1 with 1 zygomatic implant and 1 dental implant, model 2 with 1 zygomatic implant and 2 dental implants, and model 3 with 2 zygomatic implants. Locator attachments were used as a superstructure. A 150-N load was applied 3 different ways. Qualitative analysis was based on the scale of maximum principal stress; values obtained through quantitative analysis are expressed in MPa. Results In all loading conditions, model 3 (when compared models 1 and 2) showed the lowest maximum principal stress value. Model 3 is the most appropirate reconstruction in Aramany class IV maxillary defects. Two zygomatic implants can reduce the stresses in model 3. The distribution of stresses on prostheses were more rational with the help of zygoma implants, which can distribute the stresses on each part of the maxilla. Conclusions Aramany class IV obturator prosthesis placement of 2 zygomatic implants in each side of the maxilla is more advantageous than placement of dental implants. In the non-defective side, increasing the number of dental implants is not as suitable as zygomatic implants. PMID:25714086

  17. Effectiveness of Retropubic Tension-Free Vaginal Tape and Transobturator Inside-Out Tape Procedures in Women With Overactive Bladder and Stress Urinary Incontinence

    PubMed Central

    Han, Ji-Yeon; Choo, Myung-Soo; Lee, Young-Suk; Seo, Ju Tae; Kim, Jang Hwan; Kim, Young Ho

    2013-01-01

    Purpose We compared the effectiveness of the retropubic tension-free vaginal tape (TVT) and the transobturator inside-out tape (TVT-O) in treating symptoms of overactive bladder (OAB) in women with stress urinary incontinence (SUI). Methods Women with urodynamic SUI and OAB (mean urgency episodes ≥1 and frequency ≥8/24 hours on a 3-day voiding diary) were assigned to the TVT or TVT-O group. Preoperative measures were based on a urodynamic study, 3-day voiding diary, the Bristol Female Lower Urinary Tract Symptoms questionnaire (BFLUTSSF), and the urgency perception scale (UPS). At 12 postoperative months, the 3-day voiding diary, symptoms questionnaire, patient satisfaction, and standing stress test were assessed. The primary endpoint was change in the number of urgency episodes/24 hours from baseline to 12 months. Results In this group of 132 women, 42 received TVT and 90 received TVT-O. The mean urgency episodes/24 hours decreased from 6.3±5.5 to 1.6±3.2 in the TVT group and from 5.1±4.4 to 1.8±3.0 in the TVT-O group. The mean percent change was significantly greater after TVT than after TVT-O (73% vs. 60%, P=0.049). All subscales of BFLUTSSF and UPS were significantly improved using either method, with significantly greater improvement seen in the quality of life (QoL) domain after TVT (P=0.002). There were no significant differences in the cure and satisfaction rates between the two groups. Conclusions Intervention with the TVT or the TVT-O significantly improved symptoms of OAB in women with SUI and OAB. Urgency and QoL significantly improved after TVT compared with that after TVT-O. PMID:24143294

  18. Evaluating and Comparing Interventions Designed to Enhance Math Fact Accuracy and Fluency: Cover, Copy, and Compare versus Taped Problems

    ERIC Educational Resources Information Center

    Poncy, Brian C.; Skinner, Christopher H.; Jaspers, Kathryn E.

    2007-01-01

    An adapted alternating treatments design was used to evaluate and compare the effects of two procedures designed to enhance math fact accuracy and fluency in an elementary student with low cognitive functioning. Results showed that although the cover, copy, compare (CCC) and the taped problems (TP) procedures both increased the student's math fact…

  19. 21 CFR 886.1905 - Nystagmus tape.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1905 Nystagmus tape. (a) Identification. Nystagmus tape is a device that is a long, narrow strip of fabric or other flexible material on which a series of objects are...

  20. A case for automated tape in clinical imaging.

    PubMed

    Bookman, G; Baune, D

    1998-08-01

    Electronic archiving of radiology images over many years will require many terabytes of storage with a need for rapid retrieval of these images. As more large PACS installations are installed and implemented, a data crisis occurs. The ability to store this large amount of data using the traditional method of optical jukeboxes or online disk alone becomes an unworkable solution. The amount of floor space number of optical jukeboxes, and off-line shelf storage required to store the images becomes unmanageable. With the recent advances in tape and tape drives, the use of tape for long term storage of PACS data has become the preferred alternative. A PACS system consisting of a centrally managed system of RAID disk, software and at the heart of the system, tape, presents a solution that for the first time solves the problems of multi-modality high end PACS, non-DICOM image, electronic medical record and ADT data storage. This paper will examine the installation of the University of Utah, Department of Radiology PACS system and the integration of automated tape archive. The tape archive is also capable of storing data other than traditional PACS data. The implementation of an automated data archive to serve the many other needs of a large hospital will also be discussed. This will include the integration of a filmless cardiology department and the backup/archival needs of a traditional MIS department. The need for high bandwidth to tape with a large RAID cache will be examined and how with an interface to a RIS pre-fetch engine, tape can be a superior solution to optical platters or other archival solutions. The data management software will be discussed in detail. The performance and cost of RAID disk cache and automated tape compared to a solution that includes optical will be examined.

  1. Playback Station #2 for Cal Net and 5-day-recorder tapes

    USGS Publications Warehouse

    Eaton, Jerry P.

    1978-01-01

    A second system (Playback Station #2) has been set up to play back Cal Net 1" tapes and 5-day-recorder 1/2" tapes. As with the first playback system (Playback Station #1) the tapes are played back on a Bell and Howell VR3700B tape deck and the records are written out on a 16-channel direct-writing Siemens "0scillomink." Separate reproduce heads, tape guides, and tape tension sensor rollers are required for playing back 111 tapes and 1/2" tapes, but changing these tape deck components is a simple task that requires only a few minutes. The discriminators, patch panels, selector switches, filters, time code translators, and signal conditioning circuits for the time code translators and for the tape-speed-compensation signal are all mounted in an equipment rack that stands beside the playback tape deck. Changing playback speeds (15/16 ips or 3 3/4 ips) or changing from Cal Net tapes to 5-day-recorder tapes requires only flipping a few switches and/or changing a few patch cables on the patch panel (in addition to changing the reproduce heads, etc., to change from 1" tape to 1/2" tape). For the Cal Net tapes, the system provides for playback of 9 data channels (680 Hz thru 3060 Hz plus 400 Hz) and 3 time signals (IRIG-E, IRIG-C, and WWVB) at both 15/16 ips (x1 speed) and 3 3/4 ips (x4 speed). Available modes of compensation (using either a 4688 Hz reference or a 3125 Hz reference) are subtractive, capstan, capstan plus subtractive, or no compensation.

  2. Systematic Review of the Effect of Taping Techniques on Patellofemoral Pain Syndrome.

    PubMed

    Logan, Catherine A; Bhashyam, Abhiram R; Tisosky, Ashley J; Haber, Daniel B; Jorgensen, Anna; Roy, Adam; Provencher, Matthew T

    Taping is commonly used in the management of several musculoskeletal conditions, including patellofemoral pain syndrome (PFPS). Specific guidelines for taping are unknown. To investigate the efficacy of knee taping in the management of PFPS. Our hypothesis was that tension taping and exercise would be superior to placebo taping and exercise as well as to exercise or taping alone. The PubMed/MEDLINE, Cochrane, Rehabilitation and Sports Medicine Source, and CINAHL databases were reviewed for English-language randomized controlled trials (RCTs) evaluating the efficacy of various taping techniques that were published between 1995 and April 2015. Keywords utilized included taping, McConnell, kinesio-taping, kinesiotaping, patellofemoral pain, and knee. Studies included consisted of RCTs (level 1 or 2) with participants of all ages who had anterior knee or patellofemoral pain symptoms and had received nonsurgical management using any taping technique. Systematic review. Level 2. A checklist method was used to determine selection, performance, detection, and attrition bias for each article. A quality of evidence grading was then referenced using the validated PEDro database for RCTs. Three difference comparison groups were compared: tension taping and exercise versus placebo taping and exercise (group 1), placebo taping and exercise versus exercise alone (group 2), and tension taping and exercise versus taping alone (group 3). Five RCTs with 235 total patients with multiple intervention arms were included. Taping strategies included McConnell and Kinesiotaping. Visual analog scale (VAS) scores indicated improvement in all 3 comparison groups (group 1: 91 patients, 39% of total, mean VAS improvement 44.9 [tension taping + exercise] vs 66 [placebo taping + exercise]; group 2: 56 patients, 24% of total, mean VAS improvement 66 [placebo taping + exercise] vs 47.6 [exercise alone]; and group 3: 112 patients, 48% of total, mean VAS improvement 44.9 [tension taping + exercise

  3. Aligned Carbon Nanotube Tape for Sensor Applications

    NASA Technical Reports Server (NTRS)

    Tucker, Dennis S.

    2013-01-01

    For this effort, will concentrate on three applications: Vibration Gyroscope utilizes piezoelectric properties of the tape and Coriolis effect Accelerometer utilizes the piezoresistive property Strain Gauge utilizes piezoresistive property Accelerometer and Strain Gauge can also utilize piezoelectric effect Test piezoelectric properties using facilities at the Microfabrication Laboratory (AMRDEC) . Enhance piezoelectric effect using polyvinylidine fluoride and P(VDF ]TrFE) which is readily polarizable .Spray matrix solution while winding fiber; Sandwich of CNT tape and PVDF film (DOE .Two Level) . Construct and test prototype vibration gyroscope . Construct and test prototype accelerometer using cantilever design . Test strain sensitivity of CNT tape against industrial strain gauge . Embed CNT tape in composite samples as well as on surface and test to failure (4 ]point bend) A piezoelectric device exhibits an electrical response from a mechanical applied stress. . A piezoelectric device has both capacitance and resistance properties in which by applying an electric field from a waveform will exert a mechanical stress that can be monitored for a response. . The typical waveform applied is a sinusoidal waveform of a defined voltage for a defined period. The defined voltage is driven from 0 volts to the positive defined volts then back to 0 and driven to negative defined volts then back to 0. . Example. Vmax set to 10V and period set to 10 ms. . Voltage will start at zero, go to 10 volts, return to zero, go to ]10 volts and return to zero during 10 ms. . Applying this electrical field to a DUT, the capacitance response and resistance response can be observed. CNT tape is easier to manufacture and cheaper than micromachining silicon or other ceramic piezoelectric used in gyroscopes and accelerometers CNT tape properties can be modified during manufacture for specific application CNT tape has enhanced mechanical and thermal properties in addition to unique electrical

  4. TMR tape drive for a 15 TB cartridge

    NASA Astrophysics Data System (ADS)

    Biskeborn, Robert G.; Fontana, Robert E.; Lo, Calvin S.; Czarnecki, W. Stanley; Liang, Jason; Iben, Icko E. T.; Decad, Gary M.; Hipolito, Venus A.

    2018-05-01

    This paper highlights the development of tunnel magnetoresistive (TMR) sensors for magnetic tape recording applications. This has led to the introduction of a tape drives supporting a 15 TB native tape cartridge, currently the highest capacity available. Underscoring this development is the fact that the TMR sensors must run in continual contact with the tape media. This is contrasted with modern hard disk drive (hdd) sensors, which fly above the disk platters. Various challenges encountered in developing and deploying TMR are presented. In addition, advances to the write transducer are also discussed. Lastly, the authors show that future density scaling for tape recording, unlike that for hdd, is not facing limits imposed by photolithography or superparamagnetic physics, suggesting that cartridge capacity improvements of 4 to 6x will be achieved in the next 4 to 8 years.

  5. Survey of Scientific-Technical Tape Services.

    ERIC Educational Resources Information Center

    Carroll, Kenneth D., Ed.

    The results of a survey of commercially available tape services which can provide libraries and information centers with data bases of scientific and technical literature are reported. During the past few years there has been an increasing number of tape services entering the information resources market. Each of these services makes available to…

  6. Multiple Generations on Video Tape Recorders.

    ERIC Educational Resources Information Center

    Wiens, Jacob H.

    Helical scan video tape recorders were tested for their dubbing characteristics in order to make selection data available to media personnel. The equipment, two recorders of each type tested, was submitted by the manufacturers. The test was designed to produce quality evaluations for three generations of a single tape, thereby encompassing all…

  7. Fabrication of a 3D Printing Definitive Obturator Prosthesis: a Clinical Report.

    PubMed

    Tasopoulos, Theodoros; Kouveliotis, Georgios; Polyzois, Grigoris; Karathanasi, Vasiliki

    2017-03-01

    Digital technologies related to imaging and manufacturing provide the clinician with a wide variety of treatment options. Stereolithography (SLA) offers a simple and predictable way for an accurate reconstruction of congenital or acquired defects. A 65-years old cancer patient with non- keratinized squamous cell carcinoma of left maxillary sinus came for a prosthetic clinical evaluation. A bilateral maxillectomy was performed and the treatment plan included definite obturator prosthesis for the upper arch. CT data and 3D planning software were used to create a 3D printing plastic model of the defect. A wax pattern of the hollow bulb was fabricated and cured with heat-cured silicone soft liner. A final impression was obtained with the hollow bulb placed intraorally. The master cast was duplicated and the new cast was invested and reflasked. The flasks were opened, wax was boiled out and some space was created in the internal part of the obturator. Transparent heat cured acrylic resin was sandwiched with, at the inner part of the bulb, improving the retention between the acrylic denture base and the silicone based soft lining material. The patient was then placed on a 6-month recall. The five-year follow up consists of a chair side relining, when needed, of the definite removable prostheses. Maxillofacial surgery patients may develop postoperative complications such as trismus and pain. In these cases, the combination of digital technology and conventional techniques provide an accurate prosthetic restoration.

  8. Fabrication of a 3D Printing Definitive Obturator Prosthesis: a Clinical Report

    PubMed Central

    Kouveliotis, Georgios; Polyzois, Grigoris; Karathanasi, Vasiliki

    2017-01-01

    Introduction Digital technologies related to imaging and manufacturing provide the clinician with a wide variety of treatment options. Stereolithography (SLA) offers a simple and predictable way for an accurate reconstruction of congenital or acquired defects. Clinical case A 65-years old cancer patient with non- keratinized squamous cell carcinoma of left maxillary sinus came for a prosthetic clinical evaluation. A bilateral maxillectomy was performed and the treatment plan included definite obturator prosthesis for the upper arch. CT data and 3D planning software were used to create a 3D printing plastic model of the defect. A wax pattern of the hollow bulb was fabricated and cured with heat-cured silicone soft liner. A final impression was obtained with the hollow bulb placed intraorally. The master cast was duplicated and the new cast was invested and reflasked. The flasks were opened, wax was boiled out and some space was created in the internal part of the obturator. Transparent heat cured acrylic resin was sandwiched with, at the inner part of the bulb, improving the retention between the acrylic denture base and the silicone based soft lining material. The patient was then placed on a 6-month recall. The five-year follow up consists of a chair side relining, when needed, of the definite removable prostheses. Conclusion Maxillofacial surgery patients may develop postoperative complications such as trismus and pain. In these cases, the combination of digital technology and conventional techniques provide an accurate prosthetic restoration. PMID:28740271

  9. Editing of EIA coded, numerically controlled, machine tool tapes

    NASA Technical Reports Server (NTRS)

    Weiner, J. M.

    1975-01-01

    Editing of numerically controlled (N/C) machine tool tapes (8-level paper tape) using an interactive graphic display processor is described. A rapid technique required for correcting production errors in N/C tapes was developed using the interactive text editor on the IMLAC PDS-ID graphic display system and two special programs resident on disk. The correction technique and special programs for processing N/C tapes coded to EIA specifications are discussed.

  10. Improving the Spacelab mass memory unit tape layout with a simulation model

    NASA Technical Reports Server (NTRS)

    Noneman, S. R.

    1984-01-01

    A tape drive called the Mass Memory Unit (MMU) stores software used by Spacelab computers. MMU tape motion must be minimized during typical flight operations to avoid a loss of scientific data. A projection of the tape motion is needed for evaluation of candidate tape layouts. A computer simulation of the scheduled and unscheduled MMU tape accesses is developed for this purpose. This simulation permits evaluations of candidate tape layouts by tracking and summarizing tape movements. The factors that affect tape travel are investigated and a heuristic is developed to find a good tape layout. An improved tape layout for Spacelab I is selected after the evaluation of fourteen candidates. The simulation model will provide the ability to determine MMU layouts that substantially decrease the tape travel on future Spacelab flights.

  11. Getting in Taped, Part I and Part II

    ERIC Educational Resources Information Center

    Cundy, H. M.; Higgins, J.

    1971-01-01

    This article is in two parts: discussion of mathematical concepts involved in converting the reading from the tape-recorder counter which counts the turns of the run-off spool to that from the counter which counts turns of the take-up spool; calculating the length of tape run off when given the reading from the tape-recorder counter of the run-off…

  12. Stress analysis in oral obturator prostheses, part II: photoelastic imaging

    NASA Astrophysics Data System (ADS)

    Pesqueira, Aldiéris Alves; Goiato, Marcelo Coelho; da Silva, Emily Vivianne Freitas; Haddad, Marcela Filié; Moreno, Amália; Zahoui, Abbas; dos Santos, Daniela Micheline

    2014-06-01

    In part I of the study, two attachment systems [O-ring; bar-clip (BC)] were used, and the system with three individualized O-rings provided the lowest stress on the implants and the support tissues. Therefore, the aim of this study was to assess the stress distribution, through the photoelastic method, on implant-retained palatal obturator prostheses associated with different attachment systems: BOC-splinted implants with a bar connected to two centrally placed O-rings, and BOD-splinted implants with a BC connected to two distally placed O-rings (cantilever). One photoelastic model of the maxilla with oral-sinus-nasal communication with three parallel implants was fabricated. Afterward, two implant-retained palatal obturator prostheses with the two attachment systems described above were constructed. Each assembly was positioned in a circular polariscope and a 100-N axial load was applied in three different regions with implants by using a universal testing machine. The results were obtained through photograph record analysis of stress. The BOD system exhibited the highest stress concentration, followed by the BOC system. The O-ring, centrally placed on the bar, allows higher mobility of the prostheses and homogeneously distributes the stress to the region of the alveolar ridge and implants. It can be concluded that the use of implants with O-rings, isolated or connected with a bar, to rehabilitate maxillectomized patients allows higher prosthesis mobility and homogeneously distributes the stress to the alveolar ridge region, which may result in greater chewing stress distribution to implants and bone tissue. The clinical implication of the augmented bone support loss after maxillectomy is the increase of stress in the attachment systems and, consequently, a higher tendency for displacement of the prosthesis.

  13. Magnetic tape

    NASA Technical Reports Server (NTRS)

    Robinson, Harriss

    1992-01-01

    The move to visualization and image processing in data systems is increasing the demand for larger and faster mass storage systems. The technology of choice is magnetic tape. This paper briefly reviews the technology past, present, and projected. A case is made for standards and the value of the standards to users.

  14. Calibration tests on magnetic tape lightning current detectors

    NASA Technical Reports Server (NTRS)

    Crouch, K. E.

    1980-01-01

    The low cost, passive, peak lightning current detector (LCD) invented at the NASA/Kennedy Space Center, uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. Test results show that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10% were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. The stopwatch technique is a simple, low cost means of obtaining LCD readouts and can be used in the field to obtain immediate results. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result. If the shape of the conductor is other than circular (i.e., angle, channel, H-beam), an analysis of the magnetic field is required to use an LCD, especially at low current levels.

  15. Accuracy testing of electric groundwater-level measurement tapes

    USGS Publications Warehouse

    Jelinski, Jim; Clayton, Christopher S.; Fulford, Janice M.

    2015-01-01

    The accuracy tests demonstrated that none of the electric-tape models tested consistently met the suggested USGS accuracy of ±0.01 ft. The test data show that the tape models in the study should give a water-level measurement that is accurate to roughly ±0.05 ft per 100 ft without additional calibration. To meet USGS accuracy guidelines, the electric-tape models tested will need to be individually calibrated. Specific conductance also plays a part in tape accuracy. The probes will not work in water with specific conductance values near zero, and the accuracy of one probe was unreliable in very high conductivity water (10,000 microsiemens per centimeter).

  16. Fabrication of Polyimide-Matrix/Carbon and Boron-Fiber Tape

    NASA Technical Reports Server (NTRS)

    Belvin, Harry L.; Cano, Roberto J.; Treasure, Monte; Shahood, Thomas W.

    2007-01-01

    The term HYCARB denotes a hybrid composite of polyimide matrices reinforced with carbon and boron fibers. HYCARB and an improved process for fabricating dry HYCARB tapes have been invented in a continuing effort to develop lightweight, strong composite materials for aerospace vehicles. Like other composite tapes in this line of development, HYCARB tapes are intended to be used to build up laminated structures having possibly complex shapes by means of automated tow placement (ATP) - a process in which a computer-controlled multiaxis machine lays down prepreg tape or tows. The special significance of the present process for making dry HYCARB for ATP is that it contributes to the reduction of the overall cost of manufacturing boron-reinforced composite-material structures while making it possible to realize increased compression strengths. The present process for making HYCARB tapes incorporates a "wet to dry" process developed previously at Langley Research Center. In the "wet to dry" process, a flattened bundle of carbon fiber tows, pulled along a continuous production line between pairs of rollers, is impregnated with a solution of a poly(amide acid) in N-methyl-2-pyrrolidinone (NMP), then most of the NMP is removed by evaporation in hot air. In the present case, the polyamide acid is, more specifically, that of LaRC. IAX (or equivalent) thermoplastic polyimide, and the fibers are, more specifically, Manganite IM7 (or equivalent) polyacrylonitrile- based carbon filaments that have a diameter of 5.2 m and are supplied in 12,000-filament tows. The present process stands in contrast to a prior process in which HYCARB tape was made by pressing boron fibers into the face of a wet carbon-fiber/ poly(amide acid) prepreg tape . that is, a prepreg tape from which the NMP solvent had not been removed. In the present process, one or more layer(s) of side-by-side boron fibers are pressed between dry prepreg tapes that have been prepared by the aforementioned gwet to dry h

  17. GSFC specification electronic data processing magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Tinari, D. F.; Perry, J. L.

    1980-01-01

    The design requirements are given for magnetic oxide coated, electronic data processing tape, wound on reels. Magnetic recording tape types covered by this specification are intended for use on digital tape transports using the Non-Return-to-Zero-change-on-ones (NRZI) recording method for recording densities up to and including 800 characters per inch (cpi) and the Phase-Encoding (PE) recording method for a recording density of 1600 cpi.

  18. Portable digital pressure indicator for calibrating magnetic tape recorders

    NASA Technical Reports Server (NTRS)

    Mccormick, Royce F.; Leighty, Bradley D.

    1989-01-01

    The design of a portable Digital Pressure Indicator (DPI) to be used for calibrating the pressure systems on Langley's magnetic tape recorders is described. High-speed magnetic tape recorders require pressure (0 to 20 psig) for providing an air cushion across the tape guides and a slight vacuum (30 inch H2O) for maintaining the proper number of tape loops in the advance and feed chamber. The DPI is a hand-held device that can be quickly coupled to a magnetic tape recorder and includes a two-position switch for selecting either measured pressure or vacuum, to be displayed digitally in engineering units (psig or inches H2O). The DPI is currently in use in Langley's Analysis and Computation Division.

  19. OCLC-MARC Tape Processing: A Functional Analysis.

    ERIC Educational Resources Information Center

    Miller, Bruce Cummings

    1984-01-01

    Analyzes structure of, and data in, the OCLC-MARC record in the form delivered via OCLC's Tape Subscription Service, and outlines important processing functions involved: "unreadable tapes," duplicate records and deduping, match processing, choice processing, locations processing, "automatic" and "input" stamps,…

  20. An analysis of the surface-normal coupling efficiency of a metal grating coupler embedded in a Scotch tape optical waveguide

    NASA Astrophysics Data System (ADS)

    Barrios, Carlos Angulo; Canalejas-Tejero, Víctor

    2017-01-01

    The coupling efficiency at normal incidence of recently demonstrated aluminum grating couplers integrated in flexible Scotch tape waveguides has been analyzed theoretically and experimentally. Finite difference time domain (FDTD) and rigorously coupled wave analysis (RCWA) methods have been used to optimize the dimensions (duty cycle and metal thickness) of Scotch tape-embedded 1D Al gratings for maximum coupling at 635 nm wavelength. Good dimension and tape refractive index tolerances are predicted. FDTD simulations reveal the incident beam width and impinging position (alignment) values that avoid rediffraction and thus maximize the coupling efficiency. A 1D Al diffraction grating integrated into a Scotch tape optical waveguide has been fabricated and characterized. The fabrication process, based on pattern transfer, has been optimized to allow complete Al grating transfer onto the Scotch tape waveguide. A maximum coupling efficiency of 20% for TM-polarized normal incidence has been measured, which is in good agreement with the theoretical predictions. The measured coupling efficiency is further increased up to 28% for TM polarization under oblique incidence. Temperature dependence measurements have been also achieved and related to the simulations results and fabrication procedure.

  1. Kinesio Taping Fundamentals for the Equine Athlete.

    PubMed

    Molle, Sybille

    2016-04-01

    The Kinesio taping method was developed in Japan for use in humans in 1979. The use of complementary therapies is becoming common in equine athletes and the discovery of Kinesio taping potential brought it into the animal world. Kinesio taping can be used to treat a wide range of clinical conditions, from tendon injuries to neurologic disorders and from muscle contractures to postural insufficiencies. Its use in veterinary medicine is promising, but relies heavily on evidence-based clinical reports. Further scientific research is needed to fully understand the real effectiveness of application. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Efficacy and Safety of Tension-Free Vaginal Tape-Secur Mini-Sling Versus Standard Midurethral Slings for Female Stress Urinary Incontinence: A Systematic Review and Meta-Analysis

    PubMed Central

    Wang, Tao; Zhang, Yong

    2015-01-01

    Purpose: To assess the efficacy and safety of tension-free vaginal tape (TVT)-Secur for stress urinary incontinence (SUI). Methods: A literature review was performed to identify all published trials of TVT-Secur. The search included the following databases: MEDLINE, Embase, and the Cochrane Controlled Trial Register. Results: Seventeen publications involving a total of 1,879 patients were used to compare TVT-Secur with tension-free obturator tape (TVT-O) and TVT. We found that TVT-Secur had significant reductions in operative time, visual analog score for pain, and postoperative complications compared with TVT-O. Even though TVT-Secur had a significantly lower subjective cure rate (P<0.00001), lower objective cure rate (P<0.00001), and higher intraoperative complication rate, compared with TVT-O at 1 to 3 years, there was no significant difference between TVT-Secur and TVT-O in the subjective cure rate (odds ratio [OR], 0.49; 95% confidence interval [CI], 0.22–1.08; P=0.08), objective cure rate (OR, 0.49; 95% CI, 0.22–1.09; P=0.08), or complications at 3 to 5 years. Moreover, TVT-Secur had significantly lower subjective and objective cure rates compared with TVT. Conclusions: This meta-analysis indicates that TVT-Secur did not show an inferior efficacy and safety compared with TVT-O for SUI in 3 to 5 years, even though displaying a clear tread toward a lower efficacy in 1 to 3 years. Considering that the safety is similar, there are no advantages in using TVT-Secur. PMID:26739179

  3. Forensic utility of the carbon isotope ratio of PVC tape backings

    NASA Astrophysics Data System (ADS)

    Stern, L. A.; Thompson, A. H.; Mehltretter, A. H.; McLaskey, V.; Parish, A.; Aranda, R.

    2008-12-01

    Forensic interest in adhesive tapes with PVC-backings (polyvinyl chloride, electrical tapes) derives from their use in construction of improvised explosive devices, drug packaging and in a variety of other illicit activities. Due to the range of physical characteristics and chemical compositions of such tapes, traditional microscopic and chemical analysis of the tape backings and adhesives offer a high degree of discrimination between tapes from different manufacturers and products. To evaluate whether carbon isotope ratios may be able to increase discrimination of electrical tapes, particularly with regards to different tapes of the same product, we assessed the PVC-backings of 87 rolls of black electrical tape for their δ13C values. The adhesive on these tapes was physically removed with hexane, and plasticizers within the PVC tape backings were removed by three-20 minute extractions with chloroform. The δ13C values of the PVC tape backings ranged between -23.8 and -41.5 (‰ V-PDB). The carbon isotopic variation within a product (identical brand and product identification) is significant, based on five products with at least 3 rolls (ranges of 7.4‰ (n=3), 10.0‰ (n=6), 4.2‰ (n=16), 3.8‰ (n=6), and 11.5‰ (n=8), respectively). There was no measurable carbon isotope variation in regards to the following: a) along the length of a roll (4 samples from 1 roll); b) between the center and edge of a strip of tape (1 pair); c) between rolls assumed to be from the same lot of tape (2 pairs); d) between different rolls from the same batch of tape (same product purchased at the same time and place; 5 pairs); and e) between samples of a tape at room temperature, heated to 50° C and 80° C for 1 week. For each sample within the population of 87 tapes, carbon isotopes alone exclude 80 to 100% of the tapes as a potential match, with an average exclusion power of 92.5%, using a window of ± 0.4‰. Carbon isotope variations originate from variations in starting

  4. Method and apparatus for depositing a coating on a tape carrier

    DOEpatents

    Storer, Jonathan; Matias, Vladimir

    2010-06-15

    A system and method for depositing ceramic materials, such as nitrides and oxides, including high temperature superconducting oxides on a tape substrate. The system includes a tape support assembly that comprises a rotatable drum. The rotatable drum supports at least one tape substrate axially disposed on the surface of the drum during the deposition of metals on the tape and subsequent oxidation to form the ceramic materials. The drum is located within a stator having a slot that is axially aligned with the drum. A space exists between the drum and stator. The space is filled with a predetermined partial pressure of a reactive gas. The drum, stator, and space are heated to a predetermined temperature. To form the ceramic material on the tape substrate, the drum is first rotated to align the tape substrate with the slot, and at least one metal is deposited on the substrate. The drum then continues to rotate, bringing the tape substrate into the space, where the metal deposited on the tape substrate reacts with the reactive gas to form the ceramic material. In one embodiment, the tape support system also includes a pay-out/take-up system that co-rotates with the drum and provides a continuous length of tape substrate.

  5. Comparison of quality of obturation and instrumentation time using hand files and two rotary file systems in primary molars: A single-blinded randomized controlled trial.

    PubMed

    Govindaraju, Lavanya; Jeevanandan, Ganesh; Subramanian, E M G

    2017-01-01

    In permanent dentition, different rotary systems are used for canal cleaning and shaping. Rotary instrumentation in pediatric dentistry is an emerging concept. A very few studies have compared the efficiency of rotary instrumentation for canal preparation in primary teeth. Hence, this study was performed to compare the obturation quality and instrumentation time of two rotary files systems - Protaper, Mtwo with hand files in primary molars. Forty-five primary mandibular molars were randomly allotted to one of the three groups. Instrumentation was done using K-files in Group 1; Protaper in Group 2; and Mtwo in Group 3. Instrumentation time was recorded. The canal filling quality was assessed as underfill, optimal fill, and overfill. Statistical analysis was done using Chi-square, ANOVA, and post hoc Tukey test. No significant difference was observed in the quality of obturation among three groups. Intergroup comparison of the instrumentation time showed a statistically significant difference between the three groups. The use of rotary instrumentation in primary teeth results in marked reduction in the instrumentation time and improves the quality of obturation.

  6. Numerical and Experimental Investigation of the Electromechanical Behavior of REBCO Tapes

    NASA Astrophysics Data System (ADS)

    Allen, N. C.; Chiesa, L.; Takayasu, M.

    2015-12-01

    To fully characterize the electromechanical behavior of a Twisted Stacked-Tape Cable (TSTC) it is important to understand the performance of the individual REBCO tapes under various loading conditions. Numerical modeling and experimentation have been used to investigate the electromechanical characteristics of two commercially available REBCO tapes (SuperPower and SuNAM). Tension and combined tension-torsion experiments on single tapes have been continued, from prior preliminary studies, to characterize their critical current behavior and mechanical strength. Additionally, structural finite element analysis was performed on single tapes under tension and combined tension-torsion to investigate the strain dependence of the critical current. The numerical results were compared to the experimental findings for validation. The SuNAM experimental data matched the numerical model very well while the SuperPower tape experienced degradation at lower stress and strain than predicted in the model. The Superpower tape also displayed greater variability in critical current between different samples as compared with the SuNAM tape.

  7. Clinical Evaluation of Quality of Obturation and Instrumentation Time using Two Modified Rotary File Systems with Manual Instrumentation in Primary Teeth

    PubMed Central

    Govindaraju, Lavanya; Subramanian, EMG

    2017-01-01

    Introduction Pulp therapy in primary teeth has been performed using various instrumentation techniques. However, the conventional instrumentation technique used for root canal preparation in primary teeth is hand instrumentation. Various Nickel-Titanium (Ni-Ti) instruments are available to perform efficient root canal preparation in primary teeth. These Ni-Ti instruments has been designed to aid in better root canal preparation in permanent teeth but are rarely used in primary teeth. It is necessary to assess the feasibility of using these adult rotary files with a modified sequence in primary teeth. Aim To compare the quality of obturation and instrumentation time during root canal preparation using hand files and modified rotary file systems in primary molars. Materials and Methods Forty-five primary mandibular molars were randomly assigned to three experimental groups (n=15). Group I was instrumented using k-hand files, Group II with S2 ProTaper universal file and Group III with 0.25 tip 4% taper K3 rotary file. Standardized digital radiographs were taken before and after root canal instrumentation. Root canal preparation time was also recorded. Statistical analysis of the obtained data was done using SPSS Software version 17.0. An intergroup comparison of the instrumentation time and the quality of obturation was done using ANOVA and Chi-square test with the level of significance set at 0.05. Results No significant differences were noted with regard to the quality of obturation (p=0.791). However, a statistically significant difference was noted in the instrumentation time between the three groups (p<0.05). ProTaper rotary system had significantly lesser instrumentation time when compared to that of K3 rotary system and hand file system. Conclusion The hand files, S2 ProTaper Universal and K3 0.25 tip 4% taper files systems performed similarly with respect to the quality of obturation. There was a significant difference in instrumentation time with manual

  8. Clinical Evaluation of Quality of Obturation and Instrumentation Time using Two Modified Rotary File Systems with Manual Instrumentation in Primary Teeth.

    PubMed

    Govindaraju, Lavanya; Jeevanandan, Ganesh; Subramanian, Emg

    2017-09-01

    Pulp therapy in primary teeth has been performed using various instrumentation techniques. However, the conventional instrumentation technique used for root canal preparation in primary teeth is hand instrumentation. Various Nickel-Titanium (Ni-Ti) instruments are available to perform efficient root canal preparation in primary teeth. These Ni-Ti instruments has been designed to aid in better root canal preparation in permanent teeth but are rarely used in primary teeth. It is necessary to assess the feasibility of using these adult rotary files with a modified sequence in primary teeth. To compare the quality of obturation and instrumentation time during root canal preparation using hand files and modified rotary file systems in primary molars. Forty-five primary mandibular molars were randomly assigned to three experimental groups (n=15). Group I was instrumented using k-hand files, Group II with S2 ProTaper universal file and Group III with 0.25 tip 4% taper K3 rotary file. Standardized digital radiographs were taken before and after root canal instrumentation. Root canal preparation time was also recorded. Statistical analysis of the obtained data was done using SPSS Software version 17.0. An intergroup comparison of the instrumentation time and the quality of obturation was done using ANOVA and Chi-square test with the level of significance set at 0.05. No significant differences were noted with regard to the quality of obturation (p=0.791). However, a statistically significant difference was noted in the instrumentation time between the three groups (p<0.05). ProTaper rotary system had significantly lesser instrumentation time when compared to that of K3 rotary system and hand file system. The hand files, S2 ProTaper Universal and K3 0.25 tip 4% taper files systems performed similarly with respect to the quality of obturation. There was a significant difference in instrumentation time with manual instrumentation compared to the modified rotary file systems in

  9. Hidden order in crackling noise during peeling of an adhesive tape.

    PubMed

    Kumar, Jagadish; Ciccotti, M; Ananthakrishna, G

    2008-04-01

    We address the longstanding problem of recovering dynamical information from noisy acoustic emission signals arising from peeling of an adhesive tape subject to constant traction velocity. Using the phase space reconstruction procedure we demonstrate the deterministic chaotic dynamics by establishing the existence of correlation dimension as also a positive Lyapunov exponent in a midrange of traction velocities. The results are explained on the basis of the model that also emphasizes the deterministic origin of acoustic emission by clarifying its connection to stick-slip dynamics.

  10. Analytical investigation in bending characteristic of twisted stacked-tape cable conductor

    NASA Astrophysics Data System (ADS)

    Takayasu, Makoto; Chiesa, Luisa

    2015-12-01

    An analytical model to evaluate bending strains of a twisted stack-tape cable (TSTC) conductor has been developed. Through a comparison with experimental results obtained for a soldered 32-tape YBCO TSTC conductor, it has been found that a Perfect-Slip Model (PSM) taking into account the slipping between tapes in a stacked-tape cable during bending gives much better estimation of the bending performance compared to a No-Slip Model (NSM). In the PSM case the tapes can slip so that the internal longitudinal axial strain can be released. The longitudinal strains of compression and tension regions along the tape are balanced in one twist-pitch and cancel out evenly in a long cable. Therefore, in a cable the strains due to bending can be minimized. This is an important advantage of a TSTC conductor. The effect of the cable diameter size on the bending strain is also expected to be minor, and all tapes composing a TSTC conductor have the same strain response under bending, therefore the cable critical current can be characterized from a single tape behaviour.

  11. Cassette Tape Catalog: 1980/1981 Unabridged Supplement.

    ERIC Educational Resources Information Center

    American Child Care Services, Hampton, VA.

    This unabridged supplement to the Child Care Information Center's tape cassette catalog contains a listing of all recordings made in calendar years 1980 and 1981. This document plus "The Revised 1976 Cassette Tape Catalog,""The 1977 Addendum," and "The 1978/1979 Unabridged Supplement" together provide a complete listing of the 1,776 tape…

  12. Advanced crew procedures development techniques

    NASA Technical Reports Server (NTRS)

    Arbet, J. D.; Benbow, R. L.; Mangiaracina, A. A.; Mcgavern, J. L.; Spangler, M. C.; Tatum, I. C.

    1975-01-01

    The development of an operational computer program, the Procedures and Performance Program (PPP), is reported which provides a procedures recording and crew/vehicle performance monitoring capability. The PPP provides real time CRT displays and postrun hardcopy of procedures, difference procedures, performance, performance evaluation, and training script/training status data. During post-run, the program is designed to support evaluation through the reconstruction of displays to any point in time. A permanent record of the simulation exercise can be obtained via hardcopy output of the display data, and via magnetic tape transfer to the Generalized Documentation Processor (GDP). Reference procedures data may be transferred from the GDP to the PPP.

  13. Simulation and analysis of tape spring for deployed space structures

    NASA Astrophysics Data System (ADS)

    Chang, Wei; Cao, DongJing; Lian, MinLong

    2018-03-01

    The tape spring belongs to the configuration of ringent cylinder shell, and the mechanical properties of the structure are significantly affected by the change of geometrical parameters. There are few studies on the influence of geometrical parameters on the mechanical properties of the tape spring. The bending process of the single tape spring was simulated based on simulation software. The variations of critical moment, unfolding moment, and maximum strain energy in the bending process were investigated, and the effects of different radius angles of section and thickness and length on driving capability of the simple tape spring was studied by using these parameters. Results show that the driving capability and resisting disturbance capacity grow with the increase of radius angle of section in the bending process of the single tape spring. On the other hand, these capabilities decrease with increasing length of the single tape spring. In the end, the driving capability and resisting disturbance capacity grow with the increase of thickness in the bending process of the single tape spring. The research has a certain reference value for improving the kinematic accuracy and reliability of deployable structures.

  14. Revision with suture-tape augmentation after failed collateral ligament reconstruction for chronic interphalangeal instability of the hallux.

    PubMed

    Cho, Byung-Ki; Park, Ji-Kang; Choi, Seung-Myung; SooHoo, Nelson F

    2017-12-01

    Chronic varus instability or recurrent subluxation following isolated interphalangeal dislocation of the hallux is a rare injury. No consensus has been reached regarding the best joint-salvage procedure for patients with the failed collateral ligament reconstruction using tendon graft. We report a case who achieved satisfactory clinical outcome through a modified surgical procedure (revision collateral ligament reconstruction augmented with suture-tape). Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  15. Patellar taping, patellofemoral pain syndrome, lower extremity kinematics, and dynamic postural control.

    PubMed

    Aminaka, Naoko; Gribble, Phillip A

    2008-01-01

    Patellar taping has been a part of intervention for treatment of patellofemoral pain syndrome (PFPS). However, research on the efficacy of patellar taping on lower extremity kinematics and dynamic postural control is limited. To evaluate the effects of patellar taping on sagittal-plane hip and knee kinematics, reach distance, and perceived pain level during the Star Excursion Balance Test (SEBT) in individuals with and without PFPS. Repeated-measures design with 2 within-subjects factors and 1 between-subjects factor. The University of Toledo Athletic Training Research Laboratory. Twenty participants with PFPS and 20 healthy participants between the ages of 18 and 29 years. The participants performed 3 reaches of the SEBT in the anterior direction under tape and no-tape conditions on both legs. The participants' hip and knee sagittal-plane kinematics were measured using the electromagnetic tracking system. Reach distance was recorded by hand and was normalized by dividing the distance by the participants' leg length (%MAXD). After each taping condition on each leg, the participants rated the perceived pain level using the 10-cm visual analog scale. The participants with PFPS had a reduction in pain level with patellar tape application compared with the no-tape condition (P = .005). Additionally, participants with PFPS demonstrated increased %MAXD under the tape condition compared with the no-tape condition, whereas the healthy participants demonstrated decreased %MAXD with tape versus no tape (P = .028). No statistically significant differences were noted in hip flexion and knee flexion angles. Although patellar taping seemed to reduce pain and improve SEBT performance of participants with PFPS, the exact mechanisms of these phenomena cannot be explained in this study. Further research is warranted to investigate the effect of patellar taping on neuromuscular control during dynamic postural control.

  16. Dry Process for Making Polyimide/ Carbon-and-Boron-Fiber Tape

    NASA Technical Reports Server (NTRS)

    Belvin, Harry L.; Cano, Roberto J.; Johnston, Norman J.; Marchello, Joseph M.

    2003-01-01

    A dry process has been invented as an improved means of manufacturing composite prepreg tapes that consist of high-temperature thermoplastic polyimide resin matrices reinforced with carbon and boron fibers. Such tapes are used (especially in the aircraft industry) to fabricate strong, lightweight composite-material structural components. The inclusion of boron fibers results in compression strengths greater than can be achieved by use of carbon fibers alone. The present dry process is intended to enable the manufacture of prepreg tapes (1) that contain little or no solvent; (2) that have the desired dimensions, fiber areal weight, and resin content; and (3) in which all of the fibers are adequately wetted by resin and the boron fibers are fully encapsulated and evenly dispersed. Prepreg tapes must have these properties to be useable in the manufacture of high-quality composites by automated tape placement. The elimination of solvent and the use of automated tape placement would reduce the overall costs of manufacturing.

  17. LGSOWG CCT format CCB document: The standard CCT family of tape formats

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The tape format standardization approach recommended by the committee on CCT standardization is described and defined. All rules and conventions required to employ the superstructure approach to the CCT family of tape formats are presented for users of remote sensing data and producer of user tapes and the superstructure records are specified. The standard for future tape format design is presented as a guide to designing data records of a particular tape format. An example is provided showing how to incorporate the superstructure into an already established tape format.

  18. Personal miniature electrophysiological tape recorder

    NASA Astrophysics Data System (ADS)

    Green, H.

    1981-11-01

    The use of a personal miniature electrophysiological tape recorder to measure the physiological reactions of space flight personnel to space flight stress and weightlessness is described. The Oxford Instruments Medilog recorder, a battery-powered, four-channel cassette tape recorder with 24 hour endurance is carried on the person and will record EKG, EOG, EEG, and timing and event markers. The data will give information about heart rate and morphology changes, and document adaptation to zero gravity on the part of subjects who, unlike highly trained astronauts, are more representative of the normal population than were the subjects of previous space flight studies.

  19. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, E.B.; Muller, A.C.

    1983-07-15

    The present invention is a cable which, although constructed from inexpensive polyolefin tapes and using typical impregnating oils, furnishes high voltage capability up to 765 kV, and has such excellent dielectric characteristics and heat transfer properties that it is capable of operation at capacities equal to or higher than presently available cables at a given voltage. This is accomplished by using polyethylene, polybutene or polypropylene insulating tape which has been specially processed to attain properties which are not generally found in these materials, but are required for their use in impregnated electrical cables. Chief among these properties is compatibility with impregnating oil.

  20. Superconducting flat tape cable magnet

    DOEpatents

    Takayasu, Makoto

    2015-08-11

    A method for winding a coil magnet with the stacked tape cables, and a coil so wound. The winding process is controlled and various shape coils can be wound by twisting about the longitudinal axis of the cable and bending following the easy bend direction during winding, so that sharp local bending can be obtained by adjusting the twist pitch. Stack-tape cable is twisted while being wound, instead of being twisted in a straight configuration and then wound. In certain embodiments, the straight length should be half of the cable twist-pitch or a multiple of it.

  1. The Efficacy of the WaveOne Reciprocating File System versus the ProTaper Retreatment System in Endodontic Retreatment of Two Different Obturating Techniques.

    PubMed

    Jorgensen, Ben; Williamson, Anne; Chu, Rene; Qian, Fang

    2017-06-01

    This ex vivo study aimed to evaluate the efficacy of retreating GuttaCore (Dentsply Tulsa Dental Specialties, Tulsa, OK) and warm vertically condensed gutta-percha in moderately curved canals with 2 different systems: ProTaper Universal Retreatment (Dentsply Tulsa Dental) and WaveOne (Dentsply Tulsa Dental). Eighty mesial roots of mandibular molars were used in this study. The mesiobuccal canals in each sample were prepared to length with the WaveOne Primary file (Dentsply Tulsa Dental). The canals were obturated with either a warm vertical approach or with GuttaCore and divided into 4 retreatment groups with the same mean root curvature: warm vertical retreated with ProTaper, warm vertical retreated with WaveOne, GuttaCore retreated with ProTaper, and GuttaCore retreated with WaveOne. The warm vertical groups were obturated using a continuous-wave technique of gutta-percha compaction, and the GuttaCore groups were obturated according to the manufacturer's instructions. After allowing sealer to set, each specimen was retreated with either the ProTaper Universal Retreatment files D1, D2, or D3 or with the WaveOne Primary file to the predetermined working length. The time taken to reach the working length was recorded. Instrument fatigue and failure were also evaluated. The post hoc 2-sample t tests showed that the overall mean total time taken to reach the working length for the warm vertical groups was significantly greater than that observed for the GuttaCore groups (mean = 87.11 vs 60.16 seconds, respectively), and the overall mean total time taken to reach the working length for WaveOne was significantly greater than that observed for ProTaper (99.09 vs 48.18 seconds, respectively). Two-way analysis of variance showed a significant main effect for both the type of experiment groups (F 1,76  = 15.32, P = .0002) and the type of retreatments (F 1,76  = 54.67, P < .0001). Also, the WaveOne Primary file underwent more separations than the ProTaper files

  2. 75 FR 14628 - Pressure Sensitive Plastic Tape From Italy; Determination

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-26

    ... Plastic Tape From Italy; Determination On the basis of the record \\1\\ developed in the subject five-year... pressure sensitive plastic tape from Italy would be likely to lead to continuation or recurrence of... Publication 4128 (March 2010), entitled Pressure Sensitive Plastic Tape from Italy: Investigation No. AA1921...

  3. STS-88 Mission Highlights Resources Tape. Tape B

    NASA Technical Reports Server (NTRS)

    1999-01-01

    The STS-88 flight crew, Commander Robert D. Cabana, Pilot Frederick W. Sturckow, and Mission Specialists Nancy J. Currie, James H. Newman, Jerry L. Ross, and Sergei Krikalev present a video overview of their space flight. Tape two of three includes the installation of an S-Band to help monitor the UNITY Connecting Module, the opening of UNITY's hatch, the opening of the main compartment hatch to ZARYA Control Module, and the repair of the inflight maintenance system.

  4. Rapid prototyping of microfluidic systems using a PDMS/polymer tape composite.

    PubMed

    Kim, Jungkyu; Surapaneni, Rajesh; Gale, Bruce K

    2009-05-07

    Rapid prototyping of microfluidic systems using a combination of double-sided tape and PDMS (polydimethylsiloxane) is introduced. PDMS is typically difficult to bond using adhesive tapes due to its hydrophobic nature and low surface energy. For this reason, PDMS is not compatible with the xurography method, which uses a knife plotter and various adhesive coated polymer tapes. To solve these problems, a PDMS/tape composite was developed and demonstrated in microfluidic applications. The PDMS/tape composite was created by spinning it to make a thin layer of PDMS over double-sided tape. Then the PDMS/tape composite was patterned to create channels using xurography, and bonded to a PDMS slab. After removing the backing paper from the tape, a complete microfluidic system could be created by placing the construct onto nearly any substrate; including glass, plastic or metal-coated glass/silicon substrates. The bond strength was shown to be sufficient for the pressures that occur in typical microfluidic channels used for chemical or biological analysis. This method was demonstrated in three applications: standard microfluidic channels and reactors, a microfluidic system with an integrated membrane, and an electrochemical biosensor. The PDMS/tape composite rapid prototyping technique provides a fast and cost effective fabrication method and can provide easy integration of microfluidic channels with sensors and other components without the need for a cleanroom facility.

  5. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  6. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  7. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  8. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  9. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  10. Ankle taping does not impair performance in jump or balance tests.

    PubMed

    Abián-Vicén, Javier; Alegre, Luis M; Fernández-Rodríguez, J Manuel; Lara, Amador J; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96). The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed. Key pointsAnkle taping has no influence on balance performance.Ankle taping does not impair performance during the push-off phase of the jump.Ankle taping could increase the risk of injury during landings by increasing peak forces.

  11. Ankle Taping Does Not Impair Performance in Jump or Balance Tests

    PubMed Central

    Abián-Vicén, Javier; Alegre, Luis M.; Fernández-Rodríguez, J. Manuel; Lara, Amador J.; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96). The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed. Key pointsAnkle taping has no influence on balance performance.Ankle taping does not impair performance during the push-off phase of the jump.Ankle taping could increase the risk of injury during landings by increasing peak forces. PMID:24149902

  12. [Trans-obturator urethral sling for surgical correction of female stress urinary incontinence: Outside-in (Monarc) versus inside-out (TVT-O). Are both ways safe?].

    PubMed

    Debodinance, P

    2006-10-01

    The originally described outside-in procedure for the trans-obturator route was later turned inside-out. We wanted to demonstrate the safety of the two techniques through personal and published experience. Non-randomized, prospective, observational, open-label, longitudinal study of 100 female patients (50 TVT-O and 50 Monarc). All the female patients presented with isolated stress urinary incontinence. Only 4 patients presented with mixed incontinence in the Monarc (MON) group. Sphincter incompetence was observed 4 times in the MON group and 3 times in the TVT-O group. All the patients underwent surgery under assisted local anesthesia in a day-hospital setting. Only those patients presenting with patent established urinary incontinence, corrected by the TVT test, underwent surgery. Post-operative control was conducted at 3 months and 1 year. The duration of hospitalization was 10 h for 48 patients in the MON group and 49 in the TVTO group. The only per-operative complication was a vaginal perforation in the lateral angle of the vagina for a MON patient. Early post-operative complications were observed in the MON group: 3 cases of urinary tract infection, 1 of transient urine retention, 3 of pain in the thighs spontaneously resolving within 4 days and 1 of permanent pain in one leg at time 1 year, which remained bearable. For the TVTO group the post-operative complications consisted in: 1 case of urinary tract infection, 1 of transient retention and 4 of pain in the thigh. No hematoma was reported in either group. Among the late complications, the de novo symptoms included 1 case of imperious urges to urinate in the TVTO group and objective dysuria in 2 cases in the MON group vs. 7 in the TVTO group. There was no statistically significant between-group difference in the complications. No tape exposure was observed. Overall, the recovery rate was 90% at 1 year for MON vs. 94% for TVTO (p = NS) with 2 cases of recurrence between 3 months and 1 year in that series

  13. Obturator externus abscess in a 9-year-old child: A case report and literature review.

    PubMed

    de Bodman, Charlotte; Ceroni, Dimitri; Dufour, Justine; Crisinel, Pierre-Alex; Bregou-Bourgeois, Aline; Zambelli, Pierre-Yves

    2017-03-01

    Obturator pyomyositis is a rare condition in children. Diagnosis is often delayed because of its rarity, and the vagaries of its presentation cause it to be easily be missed. Physicians should therefore familiarize themselves with this condition and consider it as a possible differential diagnosis in patients presenting with an acutely painful hip. Inflammatory syndrome is also frequent among sufferers and the MRI is a very sensitive diagnostic tool for obturator pyomyositis. Additionally, joint fluid aspirations and blood cultures are also useful in identifying the pathogen. The appropriate antibiotic therapy provides a rapid regression of symptoms during the early stage of pyomyositis. In cases of MRI-confirmed abscess, surgical treatment is indicated. Our report focuses on a case of obturator pyomyositis in a 9-year-old boy. The child was febrile for 5 days and could only manage to walk a few steps. His hip range of motion was restricted in all directions. In addition, the patient had presented pain and swelling of his right elbow for a day, with a restriction of motion in the joint. There was a clear inflammatory syndrome. A diagnosis of hip and elbow septic arthritis was suspected, and the child underwent joint aspiration of the both cited joints. The aspiration of the elbow returned pus. Conversely, no effusion was found in the hip aspiration. The administration of empiric intravenous antibiotherapy was started. An MRI revealed an osteomyelitis of the ischio-pubic area associated with a subperiosteal abscess. Subsequently, 3 days after elbow arthrotomy, a surgical treatment was performed on the patient's right hip in order to evacuate the subperiosteal abscess and muscular collection because of the persistence of the patient's symptoms and inflammatory syndrome despite susceptible intravenous antibiotics. Postsurgery the patient showed steady improvement. Such cases demonstrate how diagnosis can be difficult because pelvic pyomyositis is often mistaken for

  14. RESIDUAL RISK ASSESSMENT: MAGNETIC TAPE ...

    EPA Pesticide Factsheets

    This document describes the residual risk assessment for the Magnetic Tape Manufacturing source category. For stationary sources, section 112 (f) of the Clean Air Act requires EPA to assess risks to human health and the environment following implementation of technology-based control standards. If these technology-based control standards do not provide an ample margin of safety, then EPA is required to promulgate addtional standards. This document describes the methodology and results of the residual risk assessment performed for the Magnetic Tape Manufacturing source category. The results of this analyiss will assist EPA in determining whether a residual risk rule for this source category is appropriate.

  15. The statistical evaluation of duct tape end match as physical evidence

    NASA Astrophysics Data System (ADS)

    Chan, Ka Lok

    Duct tapes are often submitted to crime laboratories as evidence associated with abductions, homicides, or construction of explosive devices. As a result, trace evidence examiners are often asked to analyze and compare commercial duct tapes so that they can establish possible evidentiary links. Duct tape end matches are believed to be the strongest association between exemplar and question samples because they are considered as evidence with unique individual characteristics. While end match analysis and comparison have long been undertaken by trace evidence examiners, there is a significant lack of scientific research for associating two or more segments of duct tapes. This study is designed to obtain statistical inferences on the uniqueness of duct tape tears. Three experiments were devised to compile the basis for a statistical assessment of the probability of duct tape end matches along with a proposed error rate. In one experiment, we conducted the equivalent of 10,000 end match examinations with an error rate of 0%. In the second experiment, we performed 2,704 end match examinations having 0% error rate. In the third experiment, using duct tape by an Elmendorf Tear tester, we conducted 576 end match examinations with an error rate of 0% and having all samples correctly associated. The results of this study indicate that end matches are distinguishable among a single roll of duct tape and between two different rolls of duct tape having very similar surface features and weave pattern.

  16. Kinesio® Tape Barrier Does Not Inhibit Intramuscular Cooling During Cryotherapy.

    PubMed

    Lyman, Katie J; McCrone, Michael; Hanson, Thomas A; Mellinger, Christopher D; Gange, Kara

    2018-05-29

    Allied health care professionals commonly apply cryotherapy as treatment for acute musculoskeletal trauma and the associated symptoms. Understanding the impact of a tape barrier on intramuscular temperature can assist in determining treatment duration for effective cryotherapy. To determine whether Kinesio® Tape acts as a barrier that affects intramuscular temperature during cryotherapy application. A repeated-measures, counterbalanced design in which the independent variable was tape application and the dependent variable was muscle temperature as measured by thermocouples placed 1 cm beneath the adipose layer. Additional covariates for robustness were BMI and adipose thickness. University research laboratory. 19 male college students with no contraindications to cryotherapy, no known sensitivity to Kinesio® Tape, and no reported quadriceps injury within the past six months. Topical cryotherapy: crushed-ice bags of 1 kg and 0.5 kg. Intramuscular temperature. The tape barrier had no statistically significant effect on muscle temperature. The pattern of temperature change was indistinguishable between participants with and without tape application. Findings suggest health care professionals can combine cryotherapy with a Kinesio® Tape application without any need for adjustments to cryotherapy duration.

  17. Chemistry of cometary meteoroids from video-tape records of meteor spectra

    NASA Technical Reports Server (NTRS)

    Millman, P. M.

    1982-01-01

    The chemistry of the cometary meteoroids was studied by closed circuit television observing systems. Vidicon cameras produce basic data on standard video tape and enable the recording of the spectra of faint shower meteors, consequently the chemical study is extended to smaller particles and we have a larger data bank than is available from the more conventional method of recording meteor spectra by photography. The two main problems in using video tape meteor spectrum records are: (1) the video tape recording has a much lower resolution than the photographic technique; (2) video tape is relatively new type of data storage in astronomy and the methods of quantitative photometry have not yet been fully developed in the various fields where video tape is used. The use of the most detailed photographic meteor spectra to calibrate the video tape records and to make positive identification of the more prominent chemical elements appearing in the spectra may solve the low resolution problem. Progress in the development of standard photometric techniques for the analysis of video tape records of meteor spectra is reported.

  18. Comparison of three mid-urethral tension-free tapes (TVT, TVT-O, and TVT-Secur) in the treatment of female stress urinary incontinence: 1-year follow-up.

    PubMed

    Wang, Yi-jun; Li, Fei-ping; Wang, Qian; Yang, Sen; Cai, Xian-guo; Chen, Ying-he

    2011-11-01

    The purpose of the study was to evaluate and compare the clinical values of tension-free vaginal tape (TVT), tension-free vaginal tape-transobturator (TVT-O), or tension-free vaginal tape-Secur (TVT-Secur) as treatment for female stress urinary incontinence. The pre-operative and 1-year post-operative follow-up protocols for patients who were treated with serial mid-urethral tension-free tape procedures in two hospitals from October 2008 to December 2009 were prospectively studied. These patients were randomly allocated to TVT, TVT-O, or TVT-Secur. A total of 102 women participated. At the 1-year follow-up, complications were not statistically different across the three groups except for pain in the thigh, which was more common in the TVT-O group. The overall efficacy and cure rate were similar between the TVT and TVT-O groups, but were significantly lower in the TVT-Secur group. A comparison of the three procedures shows that TVT-O is easy to operate and is as safe as TVT-Secur, and it has similar long-term efficacy to TVT, though, as one of the third-generation mid-urethral tension-free tapes, TVT-Secur is still being evaluated. Basing on the outcome of our study, it had rare complications but unsatisfactory efficacy, and we suggest that TVT-Secur is not fit for severe cases. However, observation and comparison of these groups in a larger sample size on a longer term are needed.

  19. Analysis of particulates on tape lift samples

    NASA Astrophysics Data System (ADS)

    Moision, Robert M.; Chaney, John A.; Panetta, Chris J.; Liu, De-Ling

    2014-09-01

    Particle counts on tape lift samples taken from a hardware surface exceeded threshold requirements in six successive tests despite repeated cleaning of the surface. Subsequent analysis of the particle size distributions of the failed tests revealed that the handling and processing of the tape lift samples may have played a role in the test failures. In order to explore plausible causes for the observed size distribution anomalies, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and time-of-flight secondary ion mass spectrometry (ToF-SIMS) were employed to perform chemical analysis on collected particulates. SEM/EDX identified Na and S containing particles on the hardware samples in a size range identified as being responsible for the test failures. ToF-SIMS was employed to further examine the Na and S containing particulates and identified the molecular signature of sodium alkylbenzene sulfonates, a common surfactant used in industrial detergent. The root cause investigation suggests that the tape lift test failures originated from detergent residue left behind on the glass slides used to mount and transport the tape following sampling and not from the hardware surface.

  20. Efficient Access to Massive Amounts of Tape-Resident Data

    NASA Astrophysics Data System (ADS)

    Yu, David; Lauret, Jérôme

    2017-10-01

    Randomly restoring files from tapes degrades the read performance primarily due to frequent tape mounts. The high latency and time-consuming tape mount and dismount is a major issue when accessing massive amounts of data from tape storage. BNL’s mass storage system currently holds more than 80 PB of data on tapes, managed by HPSS. To restore files from HPSS, we make use of a scheduler software, called ERADAT. This scheduler system was originally based on code from Oak Ridge National Lab, developed in the early 2000s. After some major modifications and enhancements, ERADAT now provides advanced HPSS resource management, priority queuing, resource sharing, web-browser visibility of real-time staging activities and advanced real-time statistics and graphs. ERADAT is also integrated with ACSLS and HPSS for near real-time mount statistics and resource control in HPSS. ERADAT is also the interface between HPSS and other applications such as the locally developed Data Carousel, providing fair resource-sharing policies and related capabilities. ERADAT has demonstrated great performance at BNL.

  1. Effects of kinesio taping and hot packs on premenstrual syndrome in females.

    PubMed

    Choi, Jung-Hyun

    2017-09-01

    [Purpose] This study aimed to evaluate the effects of taping and hot packs on premenstrual syndrome, in an attempt to generate basic data for physical therapy intervention for premenstrual syndrome. [Subjects and Methods] Thirty-two females in their 20s with premenstrual syndrome were randomly assigned to a taping group (n=10), hot pack group (n=11), and taping with hot pack group (n=11). Premenstrual syndrome was assessed using the Menstrual Distress Questionnaire in each participant prior to intervention and was re-assessed after applying kinesio taping and/or hot pack from 10 days before the estimated date of menstruation until the first day of menstruation. [Results] Data revealed that the taping and taping with hot pack groups showed significantly reduced premenstrual syndrome following intervention. In terms of the differences in the Menstrual Distress Questionnaire total score among the groups, the taping with hot pack and hot pack groups showed a significant difference. [Conclusion] These findings indicate that kinesio taping is an easy, non-drug intervention for female college students with premenstrual syndrome.

  2. Effects of kinesio taping and hot packs on premenstrual syndrome in females

    PubMed Central

    Choi, Jung-Hyun

    2017-01-01

    [Purpose] This study aimed to evaluate the effects of taping and hot packs on premenstrual syndrome, in an attempt to generate basic data for physical therapy intervention for premenstrual syndrome. [Subjects and Methods] Thirty-two females in their 20s with premenstrual syndrome were randomly assigned to a taping group (n=10), hot pack group (n=11), and taping with hot pack group (n=11). Premenstrual syndrome was assessed using the Menstrual Distress Questionnaire in each participant prior to intervention and was re-assessed after applying kinesio taping and/or hot pack from 10 days before the estimated date of menstruation until the first day of menstruation. [Results] Data revealed that the taping and taping with hot pack groups showed significantly reduced premenstrual syndrome following intervention. In terms of the differences in the Menstrual Distress Questionnaire total score among the groups, the taping with hot pack and hot pack groups showed a significant difference. [Conclusion] These findings indicate that kinesio taping is an easy, non-drug intervention for female college students with premenstrual syndrome. PMID:28931978

  3. Digital optical tape: Technology and standardization issues

    NASA Technical Reports Server (NTRS)

    Podio, Fernando L.

    1996-01-01

    During the coming years, digital data storage technologies will continue an aggressive growth to satisfy the user's need for higher storage capacities, higher data transfer rates and long-term archival media properties. Digital optical tape is a promising technology to satisfy these user's needs. As any emerging data storage technology, the industry faces many technological and standardization challenges. The technological challenges are great, but feasible to overcome. Although it is too early to consider formal industry standards, the optical tape industry has decided to work together by initiating prestandardization efforts that may lead in the future to formal voluntary industry standards. This paper will discuss current industry optical tape drive developments and the types of standards that will be required for the technology. The status of current industry prestandardization efforts will also be discussed.

  4. Dialects for the Stage: A Manual and Two Casette Tapes.

    ERIC Educational Resources Information Center

    Machlin, Evangeline

    This document contains a manual and two cassette tapes designed to help actors and actresses learn to speak various dialects. The tapes and the manual are arranged for the play-it-and-say-it method of dialect acquisition. The first three parts discuss the tapes and the manual in general, the dialect texts and dialect data, and the steps involved…

  5. Methods of Measuring Stress Relaxation in Composite Tape Springs

    DTIC Science & Technology

    2015-03-26

    plate in order to spread the load evenly and prevent excess torque . The plate also allows for force on the tape spring to be applied to the entire...aluminum squares that can be tightened to the base. The test fixture is secured to the marble base. The tape springs are folded in three locations with...top plate is pressed down by tightening the bolt on each nut. The tightening is complete when the tape spring just begins to create an M shape and

  6. Freeze Tape Casting of Functionally Graded Porous Ceramics

    NASA Technical Reports Server (NTRS)

    Sofie, Stephen W.

    2007-01-01

    Freeze tape casting is a means of making preforms of ceramic sheets that, upon subsequent completion of fabrication processing, can have anisotropic and/or functionally graded properties that notably include aligned and graded porosity. Freeze tape casting was developed to enable optimization of the microstructures of porous ceramic components for use as solid oxide electrodes in fuel cells: Through alignment and grading of pores, one can tailor surface areas and diffusion channels for flows of gas and liquid species involved in fuel-cell reactions. Freeze tape casting offers similar benefits for fabrication of optimally porous ceramics for use as catalysts, gas sensors, and filters.

  7. Multilingual health education tapes project.

    PubMed

    Vryheid, R

    1992-01-01

    The success of Thailand's 1985 malaria education cassette tapes project motivated the Highland Development Program to produce tapes in 6 tribal languages on family planning, maternal and child health, nutrition, and disease prevention. Staff produced tapes using a drama or radio magazine format as a series of short features with music and sound effects. Scriptwriters consulted villagers, broadcasting professionals, research workers, and health officials to tailor messages to the various hill tribes. They tried to avoid conflict between traditional and modern concepts and to minimize distrust of government services. The scriptwriters used basically short, grammatically simple sentences, and colloquial Thai to simplify translation. The staff tried to recruit literate, adult, native speakers of the target languages with some experience in health education in their own languages. Obstacles encountered with translation included some languages used an uncommon alphabet or translators did not know their own alphabet. The program backtranslated the scripts to assure the accuracy of the messages and the appropriateness of the words used. Backtranslation revealed deficiencies in the translated messages. Altering the meaning of technical terms tended to be simple mistakes, words with multiple meanings, and exaggeration of problems and/or solutions. Translators also sometimes failed to adapt cultural ideas to those of their tribes. For example, some persons translated all possible misconceptions about a disease yet the tribes did not have all the misconceptions. As of early 1992, recording, pretesting, distribution, and follow up had not yet taken place. The staff should meet with a recording studio to coordinate production including technicians and translators identifying means to communicate. Staff should be aware of signs of poor translation which they may have missed earlier and surfaces during recording. Pretesting should occur among literate and illiterate members of

  8. A Meta-Analysis of the Taped Problems Intervention

    ERIC Educational Resources Information Center

    Kleinert, Whitney L.; Codding, Robin S.; Minami, Takuya; Gould, Kaitlin

    2018-01-01

    Taped problems is an intervention strategy for addressing mathematics fluency that has been evaluated in multiple single-case design studies. Although its efficacy has been supported in individual studies, no comprehensive quantitative synthesis has been conducted on taped problems. The purpose of this study was to synthesize the literature that…

  9. Two-Piece Hollow Bulb Obturator for Postsurgical Partial Maxillectomy Defect in a Young Patient Revamping Lost Malar Prominence: A Clinical Report.

    PubMed

    Vaidya, Sharad; Parkash, Hari; Gupta, Sharad; Bhargava, Akshay; Kapoor, Charu

    2016-01-01

    The most frequent type of treatment for patients diagnosed with a malignant neoplasia of the oral cavity is surgical resection of the tumor. Ablative surgery may be followed by a reconstructive phase, in which the surgeon may choose between local flaps, nonvascularized bone grafts or free vascularized flaps to close the surgical site, depending on the general conditions of the patient. Esthetic and functional results are challenging to achieve for the prosthodontist, as variable amount of hard and soft tissues are removed. This report describes the fabrication of a two-piece hollow obturator for a 19-year-old patient who underwent wide surgical excision of the osteosarcoma of the maxilla and was rehabilitated to function. In this case, the surgical site was covered with submental flap, and the second piece of the obturator provided fullness to the lost malar prominence. © 2015 by the American College of Prosthodontists.

  10. Ankle taping: support given by different materials.

    PubMed Central

    Capasso, G; Maffulli, N; Testa, V

    1989-01-01

    Three different adhesive and two non-adhesive tapes were used by three operators to assess the compressive action exerted on the ankle at the moment of strapping, during different phases of gait, and after some days of treatment in ten volunteers. Only the adhesive tapes were still able to prevent swelling after five days. They should be used if a prolonged compressive action is required. Images Figure 1 PMID:2517042

  11. Materials for Heated Head Automated Thermoplastic Tape Placement

    NASA Technical Reports Server (NTRS)

    Jensen, Brian J.; Kinney, Megan C.; Cano, Roberto J.; Grimsley, Brian W.

    2012-01-01

    NASA Langley Research Center (LaRC) is currently pursuing multiple paths to develop out of autoclave (OOA) polymeric composite materials and processes. Polymeric composite materials development includes the synthesis of new and/or modified thermosetting and thermoplastic matrix resins designed for specific OOA processes. OOA processes currently under investigation include vacuum bag only (VBO) prepreg/composite fabrication, resin transfer molding (RTM), vacuum assisted resin transfer molding (VARTM) and heated head automated thermoplastic tape placement (HHATP). This paper will discuss the NASA Langley HHATP facility and capabilities and recent work on characterizing thermoplastic tape quality and requirements for quality part production. Samples of three distinct versions of APC-2 (AS4/PEEK) thermoplastic dry tape were obtained from two materials vendors, TENCATE, Inc. and CYTEC Engineered Materials** (standard grade and an experimental batch). Random specimens were taken from each of these samples and subjected to photo-microscopy and surface profilometry. The CYTEC standard grade of APC-2 tape had the most voids and splits and the highest surface roughness and/or waviness. Since the APC-2 tape is composed of a thermoplastic matrix, it offers the flexibility of reprocessing to improve quality, and thereby improve final quality of HHATP laminates. Discussions will also include potential research areas and future work that is required to advance the state of the art in the HHATP process for composite fabrication.

  12. A new method of measurement of tension on a moving magnetic tape

    NASA Technical Reports Server (NTRS)

    Kurtinaytis, A. K.; Lauzhinskas, Y. S.

    1973-01-01

    The possibility of no-contact measurement of the tension on a moving magnetic tape, assuming the tape is uniform, is discussed. A scheme for calculation of the natural frequency of transverse vibrations of magnetic tape is shown. Mathematical models are developed to show the relationships of the parameters. The method is applicable to the analysis of accurate tape feed mechanisms design.

  13. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    DOEpatents

    Goyal, Amit

    2013-07-09

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  14. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    DOEpatents

    Goyal, Amit [Knoxville, TN

    2012-07-24

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  15. [Efficacy of the application of kinesio tape in patients with stroke].

    PubMed

    Ortiz-Ramirez, J; Perez-De la Cruz, S

    2017-02-16

    To review the effects achieved by the kinesio tape in patients with stroke in scientific studies published on date and to discuss these findings may be of interest to neurology. An exhaustive search in the main scientific databases using keywords such as kinesio tape, kinesiotaping, musculoskeletal tape, taping medical concept was carried out. Citations of selected articles and scientific papers published on the website of the Spanish Association of Neuromuscular Bandage were analyzed. Experimental, quasi-experimental, clinical trials and case studies published were used, without limit date, with therapeutical treatment purpose provide important results. Eight articles have met the inclusion criteria. There are eight studies that examine the effect on kinesio tape on lower limb, gait and balance in this kind of therapy, even upper limb and swallowing problems that these patients could present. The kinesio tape in neurological patients can be a complementary technique that empirically provides benefits. However, better methodological quality studies demonstrating the effects attributed to him are still needed.

  16. STS-99 Mission Highlights Resource Tape, Part 1 of 2

    NASA Technical Reports Server (NTRS)

    2000-01-01

    An overview of the STS-99 Endeavour mission is given through footage of each flight day. Scenes from flight days one through ten show activities such as astronaut prelaunch procedures (breakfast, suit-up, and boarding Endeavour), launch, and on-orbit activities such as the deployment of the Shuttle Radar Topography Mission (SRTM) instrument. Crewmembers are seeing during such everyday activities as brushing their teeth, exercising (bicycle), and emerging from their sleeping bunks. One of the crewmembers shows the contents of the onboard medical kit. See 'STS-99 Mission Highlights Resource Tape, Part 2 of 2' for the activities of flight days 11-12 and the landing of Endeavour.

  17. Recovery of recordings from heat damaged magnetic tapes

    NASA Technical Reports Server (NTRS)

    Melugin, J. F.; Obrien, D. E., III

    1973-01-01

    Damaged tapes can now be repaired at home as long as damage does not extend to layer-to-layer adhesion within tape roll. Splice repaired section into good roll or cassette for copying. Every effort should be made to complete copying on first run, because fidelity in repaired section deteriorates with each repetition.

  18. Feasibility model of a high reliability five-year tape transport, volume 2

    NASA Technical Reports Server (NTRS)

    Eshleman, R. L.; Meyers, A. P.; Davidson, W. A.; Gortowski, R. C.; Anderson, M. E.

    1973-01-01

    Analysis of the design features of the modularized tape transport renders a life expectancy in excess of five years. Tests performed on the tape transport were directed toward determining its performance capability. These tests revealed that the tape jitter and skew are in the range achieved by high quality digital tape transports. Guidance of the tape in the lateral sense by the use of the two hybrid crowned rollers proved to be excellent. Tracking was maintained within less than one thousandth inch (approximately 2 micrometers). The guidance capability demonstrated makes possible the achievement of the performance objective of 7.2 x 10 to the 9th power storage capability employing 1500 ft. of one inch wide tape with a packing density of 5,000 bits per inch per track on 80 tracks. Also, the machine showed excellent characteristics operating over a wide range of tape speeds. The basic design concept lends itself to growth and adaptation to a wide range of recorder requirements.

  19. Kinesiology tape mediates soccer-simulated and local peroneal fatigue in soccer players.

    PubMed

    Farquharson, Claire; Greig, Matt

    2017-01-01

    To investigate the efficacy of kinesiology taping in mediating the influence of fatigue on ankle sprain risk, 12 male soccer players completed single-leg dynamic balance trials pre- and post-exercise (soccer-specific protocol, isokinetic ankle inversion/eversion protocol) in each of three counter-balanced taping conditions (no tape, zinc oxide tape ZO, kinesiology tape KT). Balance was quantified as the overall stability index (OSI) and directional stability indices of platform deflection. Soccer-specific fatigue only increased OSI in the no tape condition (p = 0.03), with ZO and KT trials negating a fatigue affect. Localized fatigue increased OSI in the no tape (p = 0.01) and ZO (p = 0.05) trials, with no increase in the KT trial. A similar pattern was observed in medio-lateral and anterio-posterior balance indices. KT mediates soccer-simulated and local peroneal fatigue, with practical implications for epidemiological observations of increased injury risk during the latter stages of match play.

  20. Software Computes Tape-Casting Parameters

    NASA Technical Reports Server (NTRS)

    deGroh, Henry C., III

    2003-01-01

    Tcast2 is a FORTRAN computer program that accelerates the setup of a process in which a slurry containing metal particles and a polymeric binder is cast, to a thickness regulated by a doctor blade, onto fibers wound on a rotating drum to make a green precursor of a metal-matrix/fiber composite tape. Before Tcast2, setup parameters were determined by trial and error in time-consuming multiple iterations of the process. In Tcast2, the fiber architecture in the final composite is expressed in terms of the lateral distance between fibers and the thickness-wise distance between fibers in adjacent plies. The lateral distance is controlled via the manner of winding. The interply spacing is controlled via the characteristics of the slurry and the doctor-blade height. When a new combination of fibers and slurry is first cast and dried to a green tape, the shrinkage from the wet to the green condition and a few other key parameters of the green tape are measured. These parameters are provided as input to Tcast2, which uses them to compute the doctor-blade height and fiber spacings needed to obtain the desired fiber architecture and fiber volume fraction in the final composite.

  1. Contact Analog/Compressed Symbology Heading Tape Assessment

    NASA Technical Reports Server (NTRS)

    Shively, R. Jay; Atencio, Adolph; Turpin, Terry; Dowell, Susan

    2002-01-01

    A simulation assessed the performance, handling qualities and workload associated with a contact-analog, world-referenced heading tape as implemented on the Comanche Helmet Integrated Display Sight System (HIDSS) when compared with a screen-fixed, compressed heading tape. Six pilots, four active duty Army Aviators and two civilians flew three ADS-33 maneuvers and a traffic pattern in the Ames Vertical Motion Simulation facility. Small, but statistically significant advantages were found for the compressed symbology for handling qualities, workload, and some of the performance measures. It should be noted however that the level of performance and handling qualities for both symbology sets fell within the acceptable tolerance levels. Both symbology sets yield satisfactory handling qualities and performance in velocity stabilization mode and adequate handling qualities in the automatic flight control mode. Pilot comments about the contact analog symbology highlighted the lack of useful rate of change information in the heading tape and "blurring" due to the rapid movement of the heading tape. These issues warrant further study. Care must be taken in interpreting the operational significance of these results. The symbology sets yielded categorically similar data, i.e., acceptable handling qualities and adequate performance, so while the results point to the need for further study, their operational significance has yet to be determined.

  2. NASA Global Atmospheric Sampling Program (GASP) data report for tape VL0014

    NASA Technical Reports Server (NTRS)

    Briehl, D.; Dudzinski, T. J.; Liu, D. C.

    1980-01-01

    The data currently available from GASP, including flight routes and dates, instrumentation, data processing procedures, and data tape specifications are described. Measurements of atmospheric ozone, cabin ozine, carbon monoxide, water vapor, particles, clouds, condensation nuclei, filter samples and related meteorological and flight information obtained during 562 flights of aircraft N533PA, N4711U, N655PA, and VH-EBE from October 3, 1977 through January 5, 1978 are reported. Data representing tropopause pressures obtained from time and space interpolation of National Meteorological Center archived data for the dates of the flights are included.

  3. Mirror-touch and ticker tape experiences in synesthesia

    PubMed Central

    Chun, Charlotte A.; Hupé, Jean-Michel

    2013-01-01

    A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia's connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person's arm being stroked can evoke physical touch sensation on one's own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker's mouth. To explore synesthesia's associations with these phenomena, a diverse group (n = 3743) was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1017 eligible respondents, synesthetes (across all subtypes) reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However, effect sizes were small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2–4%) and sequence-space synesthesia (9–14%). Within synesthesia, grapheme-personification, also called ordinal-linguistic personification (OLP) was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect sizes. PMID

  4. 21 CFR 878.4730 - Surgical skin degreaser or adhesive tape solvent.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical skin degreaser or adhesive tape solvent... Surgical skin degreaser or adhesive tape solvent. (a) Identification. A surgical skin degreaser or an... dissolve surface skin oil or adhesive tape. (b) Classification. Class I (general controls). The device is...

  5. Effects of Kinesio taping and exercise on forward head posture.

    PubMed

    Shih, Hsu-Sheng; Chen, Shu-Shi; Cheng, Su-Chun; Chang, Hsun-Wen; Wu, Pei-Rong; Yang, Jin-Shiou; Lee, Yi-Shuang; Tsou, Jui-Yi

    2017-01-01

    Little is known about the effects of Kinesio taping and therapeutic exercise on correcting forward head posture. To compare Kinesio taping versus therapeutic exercise for forward head posture on static posture, dynamic mobility and functional outcomes. Sixty subjects (31 women, 29 men) with forward head postures participated in this study. They were randomly assigned to either one of the three groups: (1) exercise group (n = 20), (2) taping group (n = 20), and (3) control groups (n = 20). The horizontal forward displacement (HFD) between ear lobe and acromion process, upper cervical and lower cervical angle (UCA, LCA), active range of motion (AROM) of cervical spine, and neck disability index (NDI) were measured before and after a 5-week intervention, and a 2-week follow-up. Data were analyzed by means of a mixed design repeated-measures ANOVA. Both taping and exercise groups showed significant improvements in HFD compared with the control group at post-treatment and follow-up. Compared with the control group, the exercise group exhibited significant improvements in the LCA and the side bending AROM at post-treatment. Both Kinesio taping and therapeutic exercise improve forward head posture after intervention and a 2-week follow-up. The effectiveness of therapeutic exercise is better than taping.

  6. Kinesio Taping effects on knee extension force among soccer players.

    PubMed

    Serra, Maysa V G B; Vieira, Edgar R; Brunt, Denis; Goethel, Márcio F; Gonçalves, Mauro; Quemelo, Paulo R V

    2015-01-01

    Kinesio Taping (KT) is widely used, however the effects of KT on muscle activation and force are contradictory. To evaluate the effects of KT on knee extension force in soccer players. This is a clinical trial study design. Thirty-four subjects performed two maximal isometric voluntary contractions of the lower limbs pre, immediately post, and 24 hours after tape application on the lower limbs. Both lower limbs were taped, using K-Tape and 3M Micropore tape randomly on the right and left thighs of the participants. Isometric knee extension force was measured for dominant side using a strain gauge. The following variables were assessed: peak force, time to peak force, rate of force development until peak force, time to peak rate of force development, and 200 ms pulse. There were no statistically significant differences in the variables assessed between KT and Micropore conditions (F=0.645, p=0.666) or among testing sessions (pre, post, and 24h after) (F=0.528, p=0.868), and there was no statistical significance (F=0.271, p=0.986) for interaction between tape conditions and testing session. KT did not affect the force-related measures assessed immediately and 24 hours after the KT application compared with Micropore application, during maximal isometric voluntary knee extension.

  7. Effects of kinesio tape to reduce hand edema in acute stroke.

    PubMed

    Bell, Alison; Muller, Melissa

    2013-01-01

    The purpose of the study was to evaluate the effi cacy of Kinesio Tape (Kinesio USA, Albequerque, NM) for reducing hand edema in individuals with hemiplegia post stroke. Seventeen individuals who experienced acute stroke were screened for visual signs of edema and were randomly assigned to experimental and control groups. The experimental group received Kinesio Tape that was applied to hand and forearm for 6 days in combination with standard therapy; the control group received standard therapy. Blinded raters assessed edema reduction via circumferential measurements. Application of Kinesio Tape did not result in statistically signifi cant reduction in edema. Large and medium effect sizes were seen for edema reduction at the metacarpophalangeal and wrist joints, respectively, with Kinesio Tape. Further research is warranted to investigate the utility of Kinesio Tape in edema reduction.

  8. Induction Bonding of Prepreg Tape and Titanium Foil

    NASA Technical Reports Server (NTRS)

    Messier, Bernadette C.; Hinkley, Jeffrey A.; Johnston, Norman J.

    1998-01-01

    Hybrid structural laminates made of titanium foil and carbon fiber reinforced polymer composite offer a potential for improved performance in aircraft structural applications. To obtain information needed for the automated fabrication of hybrid laminates, a series of bench scale tests were conducted of the magnetic induction bonding of titanium foil and thermoplastic prepreg tape. Foil and prepreg specimens were placed in the gap of a toroid magnet mounted in a bench press. Several magnet power supplies were used to study power at levels from 0.5 to 1.75 kW and frequencies from 50 to 120 kHz. Sol-gel surface-treated titanium foil, 0.0125 cm thick, and PIXA/IM7 prepreg tape were used in several lay-up configurations. Data were obtained on wedge peel bond strength, heating rate, and temperature ramp over a range of magnet power levels and frequencies at different "power-on" times for several magnet gap dimensions. These data will be utilized in assessing the potential for automated processing. Peel strengths of foil-tape bonds depended on the maximum temperature reached during heating and on the applied pressure. Maximum peel strengths were achieved at 1.25kW and 8OkHz. Induction heating of the foil appears to be capable of good bonding up to 10 plies of tape. Heat transfer calculations indicate that a 20-40 C temperature difference exists across the tape thickness during heat-up.

  9. Report of the Tape Recorder Action Plan Committee, 21 March 1972

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A NASA/AF Tape Recorder Action Plan Committee was formed in January 1972 to investigate tape recorder problems and to recommend an action plan to NASA management. The committee collected data on tape recorder failure history, pinpointed problem areas, discussed needed technical and management changes, and proposed an action plan for the recommended approaches.

  10. Compilation of fatigue, fatigue-crack propagation, and fracture data for 2024 and 7075 aluminum, Ti-6Al-4V titanium, and 300M steel. Volume 1: Description of data and data storage on magnetic tape. Volume 2: Data tape (7-track magnetic tape)

    NASA Technical Reports Server (NTRS)

    Rice, R. C.; Reynolds, J. L.

    1976-01-01

    Fatigue, fatigue-crack-propagation, and fracture data compiled and stored on magnetic tape are documented. Data for 202 and 7075 aluminum alloys, Ti-6Al-4V titanium alloy, and 300M steel are included in the compilation. Approximately 4,500 fatigue, 6,500 fatigue-crack-propagation, and 1,500 fracture data points are stored on magnetic tape. Descriptions of the data, an index to the data on the magnetic tape, information on data storage format on the tape, a listing of all data source references, and abstracts of other pertinent test information from each data source reference are included.

  11. An efficient, modular and simple tape archiving solution for LHC Run-3

    NASA Astrophysics Data System (ADS)

    Murray, S.; Bahyl, V.; Cancio, G.; Cano, E.; Kotlyar, V.; Kruse, D. F.; Leduc, J.

    2017-10-01

    The IT Storage group at CERN develops the software responsible for archiving to tape the custodial copy of the physics data generated by the LHC experiments. Physics run 3 will start in 2021 and will introduce two major challenges for which the tape archive software must be evolved. Firstly the software will need to make more efficient use of tape drives in order to sustain the predicted data rate of 150 petabytes per year as opposed to the current 50 petabytes per year. Secondly the software will need to be seamlessly integrated with EOS, which has become the de facto disk storage system provided by the IT Storage group for physics data. The tape storage software for LHC physics run 3 is code named CTA (the CERN Tape Archive). This paper describes how CTA will introduce a pre-emptive drive scheduler to use tape drives more efficiently, will encapsulate all tape software into a single module that will sit behind one or more EOS systems, and will be simpler by dropping support for obsolete backwards compatibility.

  12. Tools for applying lead tape to flat conductor cabling for chemical stripping

    NASA Technical Reports Server (NTRS)

    Angele, W.

    1969-01-01

    Two tools facilitate chemical stripping of insulation on flat conductor cabling. A tape pressing tool and a taping fixture apply adhesive lead tape with the proper amount of pressure to protect the remaining insulation from the chemical stripping solution.

  13. Effects of a modified technique for TVT-O positioning on postoperative pain: single-blind randomized study.

    PubMed

    Tommaselli, Giovanni A; Formisano, Carmen; Di Carlo, Costantino; Fabozzi, Annamaria; Nappi, Carmine

    2012-09-01

    One of the most frequent and distressing complications of the tension-free vaginal tape obturator (TVT-O) procedure for stress urinary incontinence (SUI) is groin pain, which may be related to the surgical technique or to the tape. The aim of this study was to evaluate the impact of a more limited dissection and a more medial trocar trajectory in TVT-O positioning on postoperative pain. Seventy-two SUI patients were randomized to undergo TVT-O either with the traditional technique (group A) or a modified procedure (reduced paraurethral dissection and a more medial trocar trajectory) (group B). Visual analog scale pain scores 12 h, 24 h, and 1 month after the procedure, number of analgesic vials, objective cure rate, and patient functional and quality of life scores 6 months after the procedure were evaluated. Data were analyzed by the Student's t test for parametric variables, the Mann-Whitney U and Wilcoxon tests for nonparametric variables, and Fisher's exact test for categorical variables. Pain scores were significantly lower in group B compared with group A 24 h after surgery (P = 0.01). Pain scores significantly decreased from 12-24 h postoperatively to 1 month follow-up in both groups (P < 0.001). No significant differences were observed in the number of analgesic vials administered, cure rates, and questionnaire scores between the two groups. More limited dissection and a more medial trocar trajectory of TVT-O seem to reduce postoperative groin pain at 24 h after the procedure, but not the analgesic requirement.

  14. Generation and physical characteristics of the ERTS MSS system corrected computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1973-01-01

    The generation and format are discussed of the ERTS system corrected multispectral scanner computer compatible tapes. The discussion includes spacecraft sensors, scene characteristics, data transmission, and conversion of data to computer compatible tapes at the NASA Data Processing Facility. Geometeric and radiometric corrections, tape formats, and the physical characteristics of the tapes are also included.

  15. The effective resistance between twisted superconducting filaments in tapes

    NASA Astrophysics Data System (ADS)

    Takács, S.; Iwakuma, M.; Funaki, K.

    2001-05-01

    We consider two mechanisms, which influence the effective resistance between crossing strands on flat cables or filaments in twisted tapes. The one-layer classical Rutherford-type cable and the tapes with twisted BSCCO filaments in silver matrix are taken as analogous cases. The amount of the matrix between strands or filaments increases the effective conductance compared with the direct current paths (determined by the touching area of the filaments). The increase factor is about two and can easily be suppressed by other effects, like the contact resistance between the superconductor and the matrix. The second mechanism is due to the existence of induced voltage between any points of crossing filaments. This leads to an additional effective conductance, proportional to the square of the total number of filaments. Both effects are not very important for isotropic superconductors, but due to the strong anisotropy of critical parameters they can dominate for high temperature superconductors. The first one may partially compensate the influence of the usually weaker critical current density perpendicular to the tape. The contribution due to the second effect can explain the higher resistivity of the matrix in BSCCO tapes compared with pure silver. It seems that to obtain low AC coupling losses in BSCCO tapes, structures with small filament number are required.

  16. Surreptitious Taping: The Arguments for and the Ethics against.

    ERIC Educational Resources Information Center

    Cooper, Thomas W.

    Much discussion within media ethics has focused on the acceptability of surreptitious tape recording of news sources by media professionals. The most common legal and social arguments supporting secret taping assert that recorders "hear" and "remember" better, are expedient and practical, protect against libel suits, provide…

  17. Ankle Spatting Compared to Bracing or Taping during Maximal-Effort Sprint Drills

    PubMed Central

    REUTER, GRANT D; DAHL, ANGELA R; SENCHINA, DAVID S

    2011-01-01

    The purpose of this study was to compare the influences of 4 ankle conditions (no support, bracing, taping, taping + spatting; all in football cleats) during 2 maximal-effort field drills (40-yd dash and 34-yd cutting drill) on perceptions of comfort and stability and performance outcomes. Fourteen young adult males participated. Subjects’ perceptions of comfort and stability were assessed by visual analogue scales after each drill for each ankle condition. Time-to-completion and post-completion heart rate were recorded. For both drills, significant differences in comfort perception were found such that subjects perceived no support as equivocal to bracing but more comfortable than either taping or spatting + taping. Stability results differed by drill. For the dash, significant differences in stability perception were found such that subjects perceived no support as equivocal to bracing but less stable than either taping or spatting + taping. By contrast, for the cutting drill significant differences in stability perception were found such that subjects perceived their ankles as less stable during the no support condition as compared to all 3 other conditions. Generally, bracing was perceived as equivocal to all 3 other conditions for comfort and stability. There were no significant differences in time-to-completion or heart rate for any comparison. Compared to bracing or taping, spatting + taping (a) did not influence performance time in explosive/sprint-type drills, (b) was perceived as equivalent to taping alone in terms of ankle comfort and stability, and (c) was perceived as equivalent to bracing in terms of stability but not comfort. PMID:27478530

  18. Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grin, A.; Lstiburek, J.

    The goal of this research is to provide durable and long-term water management solutions using exterior insulating sheathing as part of the water management system. It is possible to tape or seal the joints in insulating sheathing to create a drainage plane and even an air control layer. There exists the material durability component of the tape as well as the system durability component being the taped insulating sheathing as the drainage plane. This measure guideline provides best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant issues weremore » discussed with the group, which are required to make taped insulating sheathing a simple, long-term, and durable drainage plane: horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists use superior materials; and frequent installation inspection and regular trade training are required to maintain proper installation.« less

  19. Kinesio Taping effects on knee extension force among soccer players

    PubMed Central

    Serra, Maysa V. G. B.; Vieira, Edgar R.; Brunt, Denis; Goethel, Márcio F.; Gonçalves, Mauro; Quemelo, Paulo R. V.

    2015-01-01

    Background: Kinesio Taping (KT) is widely used, however the effects of KT on muscle activation and force are contradictory. Objective: To evaluate the effects of KT on knee extension force in soccer players. Method: This is a clinical trial study design. Thirty-four subjects performed two maximal isometric voluntary contractions of the lower limbs pre, immediately post, and 24 hours after tape application on the lower limbs. Both lower limbs were taped, using K-Tape and 3M Micropore tape randomly on the right and left thighs of the participants. Isometric knee extension force was measured for dominant side using a strain gauge. The following variables were assessed: peak force, time to peak force, rate of force development until peak force, time to peak rate of force development, and 200 ms pulse. Results: There were no statistically significant differences in the variables assessed between KT and Micropore conditions (F=0.645, p=0.666) or among testing sessions (pre, post, and 24h after) (F=0.528, p=0.868), and there was no statistical significance (F=0.271, p=0.986) for interaction between tape conditions and testing session. Conclusion: KT did not affect the force-related measures assessed immediately and 24 hours after the KT application compared with Micropore application, during maximal isometric voluntary knee extension. PMID:25789557

  20. Corrosion of metal particle and metal evaporated tapes

    NASA Technical Reports Server (NTRS)

    Speliotis, Dennis E.

    1991-01-01

    Very high coercivity metal particle (MP) and metal evaporated (ME) tapes are being used in 8mm video and digital audio tape applications, and more recently in digital data recording applications. In view of the inherent susceptibility of such media to environmental corrosion, a number of recent studies have addressed their long term stability and archivability. These studies have used an accelerated corrosion test based either on elevated temperature-humidity or polluting gas atmospheres known as Battelle tests. A comparison of the Battelle test results performed at different laboratories reveals a large variation from one location to another, presumably due to incorrect replication of the Battelle condition. Furthermore, when the Battelle tests are performed on enclosed cartridges, it is quite possible that diffusion limits the penetration of the extremely low concentration polluting gaseous species to the inner layers of the tapes during the short time of the accelerated test, whereas in real life these diffusion limitations may not apply. To avoid this uncertainty, the corrosion behavior of commercial 8mm MP and ME tapes when cassettes without their external plastic cases were exposed to 50 deg C and 80 percent RH for 7.5 weeks is investigated.

  1. Flexible storage medium for write-once optical tape

    NASA Technical Reports Server (NTRS)

    Strandjord, Andrew J. G.; Webb, Steven P.; Perettie, Donald J.; Cipriano, Robert A.

    1993-01-01

    A write-once data storage media was developed which is suitable for optical tape applications. The media is manufactured using a continuous film process to deposit a ternary alloy of tin, bismuth, and copper. This laser sensitive layer is sputter deposited onto commercial plastic web as a single-layer thin film. A second layer is sequentially deposited on top of the alloy to enhance the media performance and act as an abrasion resistant hard overcoat. The media was observed to have laser write sensitivities of less than 2.0 njoules/bit, carrier-to-noise levels of greater than 50dB's, modulation depths of approximately 100 percent, read-margins of greater than 35, uniform grain sizes of less than 200 Angstroms, and a media lifetime that exceeds 10 years. Prototype tape media was produced for use in the CREO drive system. The active and overcoat materials are first sputter deposited onto three mil PET film in a single pass through the vacuum coating system, and then converted down into multiple reels of 35mm x 880m tape. One mil PET film was also coated in this manner and then slit and packaged into 3480 tape cartridges.

  2. Effects of Corrective Taping on Balance and Gait in Patients With Hallux Valgus.

    PubMed

    Gur, Gozde; Ozkal, Ozden; Dilek, Burcu; Aksoy, Songul; Bek, Nilgun; Yakut, Yavuz

    2017-05-01

    Taping is an effective temporary therapy for improving hallux valgus (HV) in adults. Although HV has been demonstrated to impair postural balance, there is a lack of information about how corrective taping affects balance and gait patterns in adults with HV deformity. Eighteen middle-aged female patients (average age, 53.5 years) with HV were included. Corrective tape was applied to correct HV angulation. A series of balance and gait stability tests were performed before applying tape and 1 hour after the tape was applied with a Balance Master computerized posturography device. The study involved the following tests: modified clinical test of sensory interaction and balance (mCTSIB), unilateral stance (US), limit of stability (LoS), step up/over (SUO), and walk across (WA) tests. No significant difference was found between the no-tape and taped condition in the static balance mCTSIB and US tests ( P > .05). The taping intervention resulted in significant improvement in the dynamic balance measures for the LoS test's backward reaction time and left maximum excursion ( P < .05), a significantly higher impact index bilaterally in the SUO assessment ( P < .05), and an increase in step width mean and variability in the WA test ( P < .05). Taping for correcting HV angulation had negative acute effects on dynamic balance in the SUO and WA tests and positive effects in the LoS test. Corrective taping, although a form of conservative treatment for hallux valgus, has been insufficiently studied in terms of effects on balance. Our results show that taping, as an acute effect, may impair balance in middle-aged adults when walking or ascending and descending stairs.

  3. Method for braze-joining spirally wound tapes to inner walls of heat exchanger tubes

    DOEpatents

    Garrison, Melton E.

    1984-01-01

    The present invention is directed to a method of fabricating heat exchanger tubes in which twisted tapes are utilized for promoting turbulence and heat transfer. The method of the present invention provides for the brazing of the tapes to the inner walls of the tubes for enhancing heat transfer between the fluid within the conduit and a fluid medium outside of the conduit by conduction through the tape. The braze joint of the present invention is coextensive with the tape over the entire length thereof within the conduit. The practice of the present invention is achieved by placing a filler wire of brazing metal along the tape at a location removed from the side walls and then heating the conduit and tape sufficiently to effect the displacement of the filler metal by wicking to the contact point between the tape and the conduit wall to form a braze joint coextensive with the length of the tape within the conduit. This arrangement provides maximum heat transfer and assures that the tape is in contact with the conduit over the entire common length thereof.

  4. Method for braze-joining spirally wound tapes to inner walls of heat exchanger tubes

    DOEpatents

    Garrison, M.E.

    1982-09-03

    The present invention is directed to a method of fabricating heat exchanger tubes in which twisted tapes are utilized for promoting turbulence and heat transfer. The method of the present invention provides for the brazing of the tapes to the inner walls of the tubes for enhancing heat transfer between the fluid within the conduit and a fluid medium outside of the conduit by conduction through the tape. The braze joint of the present invention is coextensive with the tape over the entire length thereof within the conduit. The practice of the present invention is achieved by placing a filler wire of brazing metal along the tape at a location removed from the side walls and then heating the conduit and tape sufficiently to effect the displacement of the filler metal by wicking to the contact point between the tape and the conduit wall to form a braze joint coextensive with the length of the tape within the conduit. This arrangement provides maximum heat transfer and assures that the tape is in contact with the conduit over the entire common length thereof.

  5. Textured substrate tape and devices thereof

    DOEpatents

    Goyal, Amit

    2006-08-08

    A method for forming a sharply biaxially textured substrate, such as a single crystal substrate, includes the steps of providing a deformed metal substrate, followed by heating above the secondary recrystallization temperature of the deformed substrate, and controlling the secondary recrystallization texture by either using thermal gradients and/or seeding. The seed is selected to shave a stable texture below a predetermined temperature. The sharply biaxially textured substrate can be formed as a tape having a length of 1 km, or more. Epitaxial articles can be formed from the tapes to include an epitaxial electromagnetically active layer. The electromagnetically active layer can be a superconducting layer.

  6. Recording and wear characteristics of 4 and 8 mm helical scan tapes

    NASA Technical Reports Server (NTRS)

    Peter, Klaus J.; Speliotis, Dennis E.

    1993-01-01

    Performance data of media on helical scan tape systems (4 and 8 mm) is presented and various types of media are compared. All measurements were performed on a standard MediaLogic model ML4500 Tape Evaluator System with a Flash Converter option for time based measurements. The 8 mm tapes are tested on an Exabyte 8200 drive and 4 mm tapes on an Archive Python drive; in both cases, the head transformer is directly connected to a Media Logic Read/Write circuit and test electronics. The drive functions only as a tape transport and its data recover circuits are not used. Signal to Noise, PW 50, Peak Shift and Wear Test data is used to compare the performance of MP (metal particle), BaFe, and metal evaporate (ME). ME tape is the clear winner in magnetic performance but its susceptibility to wear and corrosion, make it less than ideal for data storage.

  7. String and Sticky Tape Experiments.

    ERIC Educational Resources Information Center

    Edge, R. D., Ed.

    1979-01-01

    Explains how to demonstrate the fundamentals of one dimensional kinematics such as Newton's third law of motion, and collision between bodies, using simple materials of marbles, strings, sticky tape, drinking straws, and rubber bands. (GA)

  8. Helical tape forming device

    NASA Technical Reports Server (NTRS)

    Bush, J. E.; Cole, P. T.

    1969-01-01

    Using a device that is not limited to a minimum thickness or width-to-thickness ratio, a very thin metal tape or ribbon is formed into a continuous flat wound helical coil. The device imparts the desired circular shape by squeeze rolling it with an unequal force across its width.

  9. Torsional Properties of TiNi Shape Memory Alloy Tape for Rotary Actuator

    NASA Astrophysics Data System (ADS)

    Takeda, K.; Tobushi, H.; Mitsui, K.; Nishimura, Y.; Miyamoto, K.

    2012-12-01

    In order to develop novel shape memory actuators, the torsional deformation of a shape memory alloy (SMA) tape and the actuator models driven by the tape were investigated. The results obtained can be summarized as follows. In the SMA tape subjected to torsion, the martensitic transformation appears along both edges of the tape due to elongation of these elements and grows to the central part. The fatigue life in both the pulsating torsion and alternating torsion is expressed by the unified relationship of the dissipated work in each cycle. Based on an opening and closing door model and a solar-powered active blind model, the two-way rotary driving actuator with a small and simple mechanism can be developed by using torsion of the SMA tape.

  10. Does Kinesiology tape counter exercise-related impairments of balance in the elderly?

    PubMed

    Hosp, Simona; Csapo, Robert; Heinrich, Dieter; Hasler, Michael; Nachbauer, Werner

    2018-05-01

    Maintaining balance is an essential requirement for the performance of daily tasks and sporting activities, particularly in older adults to prevent falls and associated injuries. Kinesiology tape has gained great popularity in sports and is frequently used as a tool for performance enhancement. However, there is little research investigating its influence on balance. The purpose of this study was to evaluate the effect of Kinesiology tape on dynamic balance, postural stability and knee proprioception after physical activity in healthy, older adults. Twelve physically active, healthy men aged 63-77 years performed the test on two separate days, with and without Kinesiology tape at the knee joint (prospective intervention with cross-over design). Dynamic balance during an obstacle-crossing task, postural stability in a single-leg stance test, and knee joint position sense as a measure of proprioception were examined before and after 30 min of downhill walking on a treadmill. The influences of taping condition and physical activity on all parameters were statistically tested using factorial ANOVAs. Factorial ANOVA revealed significant time × taping condition interaction effects on all performance parameters (p < 0.05), indicating that the exercise-related changes in dynamic balance, postural stability and knee proprioception differed between the two taping conditions. The deterioration of performance was always greater when no tape was used. This study demonstrated that physical exercise significantly deteriorated dynamic balance, postural stability and knee proprioception in older men. These effects can be attenuated through the usage of Kinesiology tape. By preventing exercise-related impairments of balance, Kinesiology tape might help reduce the risk of sports-associated falls and associated injuries. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Thermal Edge-Effects Model for Automated Tape Placement of Thermoplastic Composites

    NASA Technical Reports Server (NTRS)

    Costen, Robert C.

    2000-01-01

    Two-dimensional thermal models for automated tape placement (ATP) of thermoplastic composites neglect the diffusive heat transport that occurs between the newly placed tape and the cool substrate beside it. Such lateral transport can cool the tape edges prematurely and weaken the bond. The three-dimensional, steady state, thermal transport equation is solved by the Green's function method for a tape of finite width being placed on an infinitely wide substrate. The isotherm for the glass transition temperature on the weld interface is used to determine the distance inward from the tape edge that is prematurely cooled, called the cooling incursion Delta a. For the Langley ATP robot, Delta a = 0.4 mm for a unidirectional lay-up of PEEK/carbon fiber composite, and Delta a = 1.2 mm for an isotropic lay-up. A formula for Delta a is developed and applied to a wide range of operating conditions. A surprise finding is that Delta a need not decrease as the Peclet number Pe becomes very large, where Pe is the dimensionless ratio of inertial to diffusive heat transport. Conformable rollers that increase the consolidation length would also increase Delta a, unless other changes are made, such as proportionally increasing the material speed. To compensate for premature edge cooling, the thermal input could be extended past the tape edges by the amount Delta a. This method should help achieve uniform weld strength and crystallinity across the width of the tape.

  12. Application of Kinesio Taping method for newborn swallowing difficultly

    PubMed Central

    Lin, Chien-Lin; Wu, Wei-Ting; Chang, Ke-Vin; Lin, Hong-Yi; Chou, Li-Wei

    2016-01-01

    Abstract Background: Preterm infants are at an increased risk of sucking problems, swallowing difficulty, and poor nourishment. During the neonatal period, the neurobehavioral organization of a preterm baby is poor compared with that of appropriate gestational age infants. Kinesio Taping has been widely used for edema control, joint protection, and proprioception training. With the help of augmentation of the sensory input for muscle facilitation and inhibition through tapping, the coordination of the target muscle groups can be improved. Until now, no research is available on the use of Kinesio Taping for the swallowing difficulty of infant. Methods: We reported a preterm infant suffering from brain edema at birth and swallowing difficultly until 40 weeks. The swallowing reflex was delayed. Moreover, lip closure and rooting reflex combined with the dysfunction grade of jaw movement were poor. We performed KT methods on the baby under the theory of the direction of the tape for facilitate or inhibit the muscle. Result: After the Kinesio Taping treatment, the sucking function was improved with good lip closure.One week later, the baby was discharged without the use of an oral gastric tube. Conclusion: Kinesio Taping contributed significantly to the improvement of impaired sucking and swallowing and could be implemented as a regular rehabilitative approach for infants suffering from these difficulties. PMID:27495080

  13. The Broselow and Handtevy Resuscitation Tapes: A Comparison of the Performance of Pediatric Weight Prediction.

    PubMed

    Lowe, Calvin G; Campwala, Rashida T; Ziv, Nurit; Wang, Vincent J

    2016-08-01

    To assess the performance of two pediatric length-based tapes (Broselow and Handtevy) in predicting actual weights of US children. In this descriptive study, weights and lengths of children (newborn through 13 years of age) were extracted from the 2009-2010 National Health and Nutrition Examination Survey (NHANES). Using the measured length ranges for each tape and the NHANES-extracted length data, every case from the study sample was coded into Broselow and Handtevy zones. Mean weights were calculated for each zone and compared to the predicted Broselow and Handtevy weights using measures of bias, precision, and accuracy. A sub-sample was examined that excluded cases with body mass index (BMI)≥95th percentile. Weights of children longer than each tape also were examined. A total of 3,018 cases from the NHANES database met criteria. Although both tapes underestimated children's weight, the Broselow tape outperformed the Handtevy tape across most length ranges in measures of bias, precision, and accuracy of predicted weights relative to actual weights. Accuracy was higher in the Broselow tape for shorter children and in the Handtevy tape for taller children. Among the sub-sample with cases of BMI≥95th percentile removed, performance of the Handtevy tape improved, yet the Broselow tape still performed better. When assessing the weights of children who were longer than either tape, the actual mean weights did not approximate adult weights; although, those exceeding the Handtevy tape were closer. For pediatric weight estimation, the Broselow tape performed better overall than the Handtevy tape and more closely approximated actual weight. Lowe CG , Campwala RT , Ziv N , Wang VJ . The Broselow and Handtevy resuscitation tapes: a comparison of the performance of pediatric weight prediction. Prehosp Disaster Med. 2016;31(4):364-375.

  14. Performance of preformed plastic tapes.

    DOT National Transportation Integrated Search

    1982-01-01

    This study was initiated to investigate the overall performance of preformed pavement marking tapes with respect to their appearance, durability, and night visibility, and to recommend criteria for the selection of such materials based on their perfo...

  15. One-step Tape Casting of Composites via Slurry on Fiber

    NASA Technical Reports Server (NTRS)

    deGroh, Henry C., III

    2001-01-01

    A process by which metal matrix composites can be made was presented. The process involves putting a powder slurry on fibers to make a precursor green tape. These green tapes are cut, stacked and hot pressed to form the fully dense composite. A computer program was presented which enables complete quantification and control of the process. Once some easily obtained properties of the slurry and its behavior are determined (such as the shrinkage from the wet to green state, and the density of the green tape) modification of the fiber spacing and blade height give the maker precise control of fiber volume fraction, and fiber architecture in the composite. The process was shown to be accurate and flexible through the production of a wide variety of volume fraction fiber composites made from a wide variety of fibers and powders. The most time consuming step of the tape casting process (other than hot pressing) was winding the fiber on the drum. The tape casting techniques developed resulted in high quality metal matrix composites, with ultimate tensile strength in the range of 215 ksi (1477 MPa), a strain at failure of 1.15 percent, and in fatigue at room temperature 0 to 120 ksi, n = 0.3 Hz, a 4-ply Ti-24Al-11Nb/SCS-6, 32 vol% fiber tape cast composite lasted 202,205 cycles with a maximum strain on the 100th cycle of 0.43 percent.

  16. Transaction aware tape-infrastructure monitoring

    NASA Astrophysics Data System (ADS)

    Nikolaidis, Fotios; Kruse, Daniele Francesco

    2014-06-01

    Administrating a large scale, multi protocol, hierarchical tape infrastructure like the CERN Advanced STORage manager (CASTOR)[2], which stores now 100 PB (with an increasing step of 25 PB per year), requires an adequate monitoring system for quick spotting of malfunctions, easier debugging and on demand report generation. The main challenges for such system are: to cope with CASTOR's log format diversity and its information scattered among several log files, the need for long term information archival, the strict reliability requirements and the group based GUI visualization. For this purpose, we have designed, developed and deployed a centralized system consisting of four independent layers: the Log Transfer layer for collecting log lines from all tape servers to a single aggregation server, the Data Mining layer for combining log data into transaction context, the Storage layer for archiving the resulting transactions and finally the Web UI layer for accessing the information. Having flexibility, extensibility and maintainability in mind, each layer is designed to work as a message broker for the next layer, providing a clean and generic interface while ensuring consistency, redundancy and ultimately fault tolerance. This system unifies information previously dispersed over several monitoring tools into a single user interface, using Splunk, which also allows us to provide information visualization based on access control lists (ACL). Since its deployment, it has been successfully used by CASTOR tape operators for quick overview of transactions, performance evaluation, malfunction detection and from managers for report generation.

  17. Digital terrain tapes: user guide

    USGS Publications Warehouse

    ,

    1980-01-01

    DMATC's digital terrain tapes are a by-product of the agency's efforts to streamline the production of raised-relief maps. In the early 1960's DMATC developed the Digital Graphics Recorder (DGR) system that introduced new digitizing techniques and processing methods into the field of three-dimensional mapping. The DGR system consisted of an automatic digitizing table and a computer system that recorded a grid of terrain elevations from traces of the contour lines on standard topographic maps. A sequence of computer accuracy checks was performed and then the elevations of grid points not intersected by contour lines were interpolated. The DGR system produced computer magnetic tapes which controlled the carving of plaster forms used to mold raised-relief maps. It was realized almost immediately that this relatively simple tool for carving plaster molds had enormous potential for storing, manipulating, and selectively displaying (either graphically or numerically) a vast number of terrain elevations. As the demand for the digital terrain tapes increased, DMATC began developing increasingly advanced digitizing systems and now operates the Digital Topographic Data Collection System (DTDCS). With DTDCS, two types of data elevations as contour lines and points, and stream and ridge lines are sorted, matched, and resorted to obtain a grid of elevation values for every 0.01 inch on each map (approximately 200 feet on the ground). Undefined points on the grid are found by either linear or or planar interpolation.

  18. 40 CFR 60.715 - Test methods and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Test methods and procedures. 60.715 Section 60.715 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Magnetic Tape...

  19. Arch-Taping Techniques for Altering Navicular Height and Plantar Pressures During Activity

    PubMed Central

    Newell, Tim; Simon, Janet; Docherty, Carrie L.

    2015-01-01

    Context Arch tapings have been used to support the arch by increasing navicular height. Few researchers have studied navicular height and plantar pressures after physical activity. Objective To determine if taping techniques effectively support the arch during exercise. Design Crossover study. Setting Athletic training research laboratory. Patients or Other Participants Twenty-five individuals (13 men, 12 women; age = 20.0 ± 1.0 years, height = 172.3 ± 6.6 cm, mass = 70.1 ± 10.2 kg) with a navicular drop of more than 8 mm (12.9 ± 3.3 mm) volunteered. Intervention(s) All individuals participated in 3 days of testing, with 1 day for each tape condition: no tape, low dye, and navicular sling. On each testing day, navicular height and plantar pressures were measured at 5 intervals: baseline; posttape; and after 5, 10, and 15 minutes of running. The order of tape condition was counterbalanced. Main Outcome Measure(s) The dependent variables were navicular height in millimeters and plantar pressures in kilopascals. Plantar pressures were divided into 5 regions: medial forefoot, lateral forefoot, lateral midfoot, lateral rearfoot, and medial rearfoot. Separate repeated-measures analyses of variance were conducted for each dependent variable. Results Navicular height was higher immediately after application of the navicular-sling condition (P = .004) but was reduced after 5 minutes of treadmill running (P = .12). We observed no differences from baseline to posttape for navicular height for the low-dye (P = .30) and no-tape conditions (P = .25). Both the low-dye and navicular-sling conditions increased plantar pressures in the lateral midfoot region compared with the no-tape condition. The low-dye condition created decreased pressure in the medial and lateral forefoot regions compared with the no-tape condition. All changes were identified immediately after application and were maintained during running. No changes were noted in plantar pressures for the no-tape

  20. High-throughput DNA extraction of forensic adhesive tapes.

    PubMed

    Forsberg, Christina; Jansson, Linda; Ansell, Ricky; Hedman, Johannes

    2016-09-01

    Tape-lifting has since its introduction in the early 2000's become a well-established sampling method in forensic DNA analysis. Sampling is quick and straightforward while the following DNA extraction is more challenging due to the "stickiness", rigidity and size of the tape. We have developed, validated and implemented a simple and efficient direct lysis DNA extraction protocol for adhesive tapes that requires limited manual labour. The method uses Chelex beads and is applied with SceneSafe FAST tape. This direct lysis protocol provided higher mean DNA yields than PrepFiler Express BTA on Automate Express, although the differences were not significant when using clothes worn in a controlled fashion as reference material (p=0.13 and p=0.34 for T-shirts and button-down shirts, respectively). Through in-house validation we show that the method is fit-for-purpose for application in casework, as it provides high DNA yields and amplifiability, as well as good reproducibility and DNA extract stability. After implementation in casework, the proportion of extracts with DNA concentrations above 0.01ng/μL increased from 71% to 76%. Apart from providing higher DNA yields compared with the previous method, the introduction of the developed direct lysis protocol also reduced the amount of manual labour by half and doubled the potential throughput for tapes at the laboratory. Generally, simplified manual protocols can serve as a cost-effective alternative to sophisticated automation solutions when the aim is to enable high-throughput DNA extraction of complex crime scene samples. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  1. An in vitro comparative study of the adaptation and sealing ability of two carrier-based root canal obturators.

    PubMed

    Alkahtani, Ahmed; Al-Subait, Sara; Anil, Sukumaran

    2013-01-01

    The study was done to assess the sealing ability and adaptation of RealSeal 1, and to compare it with Thermafil. 65 single-rooted extracted teeth were selected and root canal treatment was performed. Root canals were obturated with RealSeal 1 or Thermafil. A double chamber bacterial leakage model using E. faecalis was developed to assess the sealing ability. Samples were monitored daily for 60 days. After the bacterial leakage test, samples were embedded in resin and sectioned horizontally at 2 and 4 mm from the apical foramen. Specimens were examined under scanning electron microscope and digitally photographed. AutoCAD software was used to measure the gap between the canal surface and obturation material. Results were statistically analyzed using nonparametric Kaplan-Meier survival analysis for the bacterial leakage and t-test to compare the means of gap in RealSeal 1 and Thermafil at 2 and 4 mm. There was no significant difference between the RealSeal 1 and Thermafil with respect to leakage over time. At 2 mm and 4 mm, RealSeal 1 had significantly more gaps than Thermafil. From the observations it can be concluded that RealSeal 1 and Thermafil have comparable performance in terms of adaptation and sealing ability.

  2. An In Vitro Comparative Study of the Adaptation and Sealing Ability of Two Carrier-Based Root Canal Obturators

    PubMed Central

    Alkahtani, Ahmed; Al-Subait, Sara; Anil, Sukumaran

    2013-01-01

    The study was done to assess the sealing ability and adaptation of RealSeal 1, and to compare it with Thermafil. 65 single-rooted extracted teeth were selected and root canal treatment was performed. Root canals were obturated with RealSeal 1 or Thermafil. A double chamber bacterial leakage model using E. faecalis was developed to assess the sealing ability. Samples were monitored daily for 60 days. After the bacterial leakage test, samples were embedded in resin and sectioned horizontally at 2 and 4 mm from the apical foramen. Specimens were examined under scanning electron microscope and digitally photographed. AutoCAD software was used to measure the gap between the canal surface and obturation material. Results were statistically analyzed using nonparametric Kaplan-Meier survival analysis for the bacterial leakage and t-test to compare the means of gap in RealSeal 1 and Thermafil at 2 and 4 mm. There was no significant difference between the RealSeal 1 and Thermafil with respect to leakage over time. At 2 mm and 4 mm, RealSeal 1 had significantly more gaps than Thermafil. From the observations it can be concluded that RealSeal 1 and Thermafil have comparable performance in terms of adaptation and sealing ability. PMID:23710141

  3. Tape-recorded Lectures With Slide Synchronization

    ERIC Educational Resources Information Center

    Goodhue, D.

    1969-01-01

    Describes "Taped Explanation Slide Synchronization" programs used for individual study or group showing in college zoology. Discusses preparation of programs, class organization, equipment, and costs. (EB)

  4. Postoperative groin pain and success rates following transobturator midurethral sling placement: TVT ABBREVO® system versus TVT™ obturator system.

    PubMed

    Canel, Virginie; Thubert, Thibault; Wigniolle, Ingrid; Fernandez, Hervé; Deffieux, Xavier

    2015-10-01

    Placement of a transobturator midurethral sling (MUS) is the standard surgical treatment for stress urinary incontinence. Most recent MUS procedures have been poorly evaluated. We compared the results using a "new" device expected to reduce postoperative pain, the TVT ABBREVO® system (TVT-Abb), with those using the TVT™ obturator system (TVT-O). This was a retrospective study comparing the use of the TVT-Abb (in 50 patients) and the TVT-O (in 50 patients). The main outcomes were the amount of postoperative pain, the success rate (no reported urinary leakage and negative cough test) with both MUS procedures, and the prevalence of complications. The mean follow-up time was 12 months. The preoperative characteristics of the two groups were comparable. There was less postoperative pain (VAS, 0 to 100) in the TVT-Abb group than in the TVT-O group (12.2 vs. 24.4, p < 0.01). However, at 6 weeks after surgery there was no significant difference between the two groups (p = 0.32). The incidence of de novo bladder outlet obstruction symptoms was similar in the TVT-Abb group and the TVT-O group (8 % vs. 12 %, p = 0.74). The prevalences of perioperative and postoperative complications (bladder/urethral injury, haemorrhage) in the two groups were equal. The success rates were similar at 12 months after surgery (88 % vs. 78 %, p = 0.29). The success rates with TVT-Abb and TVT-O were equal at 12 months after surgery, but there was less immediate postoperative pain with TVT-Abb.

  5. Research on resistance characteristics of YBCO tape under short-time DC large current impact

    NASA Astrophysics Data System (ADS)

    Zhang, Zhifeng; Yang, Jiabin; Qiu, Qingquan; Zhang, Guomin; Lin, Liangzhen

    2017-06-01

    Research of the resistance characteristics of YBCO tape under short-time DC large current impact is the foundation of the developing DC superconducting fault current limiter (SFCL) for voltage source converter-based high voltage direct current system (VSC-HVDC), which is one of the valid approaches to solve the problems of renewable energy integration. SFCL can limit DC short-circuit and enhance the interrupting capabilities of DC circuit breakers. In this paper, under short-time DC large current impacts, the resistance features of naked tape of YBCO tape are studied to find the resistance - temperature change rule and the maximum impact current. The influence of insulation for the resistance - temperature characteristics of YBCO tape is studied by comparison tests with naked tape and insulating tape in 77 K. The influence of operating temperature on the tape is also studied under subcooled liquid nitrogen condition. For the current impact security of YBCO tape, the critical current degradation and top temperature are analyzed and worked as judgment standards. The testing results is helpful for in developing SFCL in VSC-HVDC.

  6. The ISEE-3 ULEWAT: Flux tape description and heavy ion fluxes 1978-1984. [plasma diagnostics

    NASA Technical Reports Server (NTRS)

    Mason, G. M.; Klecker, B.

    1985-01-01

    The ISEE ULEWAT FLUX tapes contain ULEWAT and ISEE pool tape data summarized over relatively long time intervals (1hr) in order to compact the data set into an easily usable size. (Roughly 3 years of data fit onto one 1600 BPI 9-track magnetic tape). In making the tapes, corrections were made to the ULEWAT basic data tapes in order to, remove rate spikes and account for changes in instrument response so that to a large extent instrument fluxes can be calculated easily from the FLUX tapes without further consideration of instrument performance.

  7. ICI optical data storage tape: An archival mass storage media

    NASA Technical Reports Server (NTRS)

    Ruddick, Andrew J.

    1993-01-01

    At the 1991 Conference on Mass Storage Systems and Technologies, ICI Imagedata presented a paper which introduced ICI Optical Data Storage Tape. This paper placed specific emphasis on the media characteristics and initial data was presented which illustrated the archival stability of the media. More exhaustive analysis that was carried out on the chemical stability of the media is covered. Equally important, it also addresses archive management issues associated with, for example, the benefits of reduced rewind requirements to accommodate tape relaxation effects that result from careful tribology control in ICI Optical Tape media. ICI Optical Tape media was designed to meet the most demanding requirements of archival mass storage. It is envisaged that the volumetric data capacity, long term stability and low maintenance characteristics demonstrated will have major benefits in increasing reliability and reducing the costs associated with archival storage of large data volumes.

  8. Fabrication of high edge-definition steel-tape gratings for optical encoders.

    PubMed

    Ye, Guoyong; Liu, Hongzhong; Yan, Jiawei; Ban, Yaowen; Fan, Shanjin; Shi, Yongsheng; Yin, Lei

    2017-10-01

    High edge definition of a scale grating is the basic prerequisite for high measurement accuracy of optical encoders. This paper presents a novel fabrication method of steel tape gratings using graphene oxide nanoparticles as anti-reflective grating strips. Roll-to-roll nanoimprint lithography is adopted to manufacture the steel tape with hydrophobic and hydrophilic pattern arrays. Self-assembly technology is employed to obtain anti-reflective grating strips by depositing the graphene oxide nanoparticles on hydrophobic regions. A thin SiO 2 coating is deposited on the grating to protect the grating strips. Experimental results confirm that the proposed fabrication process enables a higher edge definition in making steel-tape gratings, and the new steel tape gratings offer better performance than conventional gratings.

  9. Fabrication of high edge-definition steel-tape gratings for optical encoders

    NASA Astrophysics Data System (ADS)

    Ye, Guoyong; Liu, Hongzhong; Yan, Jiawei; Ban, Yaowen; Fan, Shanjin; Shi, Yongsheng; Yin, Lei

    2017-10-01

    High edge definition of a scale grating is the basic prerequisite for high measurement accuracy of optical encoders. This paper presents a novel fabrication method of steel tape gratings using graphene oxide nanoparticles as anti-reflective grating strips. Roll-to-roll nanoimprint lithography is adopted to manufacture the steel tape with hydrophobic and hydrophilic pattern arrays. Self-assembly technology is employed to obtain anti-reflective grating strips by depositing the graphene oxide nanoparticles on hydrophobic regions. A thin SiO2 coating is deposited on the grating to protect the grating strips. Experimental results confirm that the proposed fabrication process enables a higher edge definition in making steel-tape gratings, and the new steel tape gratings offer better performance than conventional gratings.

  10. A 16-channel cassette tape recorder system for clinical EEGs.

    PubMed

    Barlow, J S

    1975-02-01

    A 16-channel EEG tape recorder system having a frequency response of DC-100 Hz for each channel is described. The system utilized standard commercially available highfidelity audio tape decks in conjunction with specially designed circuits for time-division multiplexing a balanced amplitude modulation

  11. Storage, Preservation, and Recovery of Magnetic Recording Tape

    NASA Technical Reports Server (NTRS)

    Cuddihy, Edward F.

    1994-01-01

    During the 1970's, a commercial magnetic recording tape fabricated with magnetic oxide particles, and with oxide and backcoat binders made from polyester urethane was being used for spacecraft tape recorders, and which would periodically manifest operational problems such as layer-to-layer adhesion, stick-slip, and shedding of sticky organic materials. These problems were generally associated with periods of high humidity. An experimental study identified that these problems resulted from hydrolysis of the polyester urethane binders.

  12. Ultrasound assessment of tension-free vaginal tape (TVT).

    PubMed

    Flock, F; Kohorst, F; Kreienberg, R; Reich, A

    2011-01-01

    To date, no standardization for the visualization of tension-free vaginal tape (TVT) has been established in clinical practice. The aim of this prospective observational study was to evaluate the shape and position of the tape using ultrasound and to compare this data with clinical postoperative results. In a three-year period, 296 patients with clinically and urodynamically proven stress urinary incontinence (SUI) were treated with TVT and received follow-up in our department. An additional 12 patients, who were initially treated in other hospitals and had postoperative problems, were included in this study. Depending on the outcome after 3 months, the patients were divided into groups with and without specific disorders. The TVT was evaluated by introital ultrasound. The position of the tape was established by its location in relation to the urethral length and the distance to the hypoechoic center of the urethra (HCU). A suitable TVT position was determined in patients without any postoperative disorders. The mean value for the TVT position at rest in relation to the urethral length was 61 %. The distance to the HCU was 4.6 ± 1.5 mm. In patients with persistent SUI, the tape was more often located under the inner (3 % vs. 0 %) or outer quarter (29 % vs. 13 %, p = 0.004). In patients with residual volume, the distance to the urethra was significantly lower (2.7 vs. 4.6, p < 0.001). TVT may be regularly investigated using ultrasound. In combination with the clinical outcome, it represents an important method of evaluating the tape and assists in the planning of a future therapeutic course of action in cases of postoperative problems. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Burnout Test of First- and Second-Generation HTS Tapes in Liquid-Nitrogen Bath Cooling

    NASA Astrophysics Data System (ADS)

    Young, M. A.; Demko, J. A.; Duckworth, R. C.; Lue, J. W.; Gouge, M. J.; Pace, M. O.

    2004-06-01

    A series of BSCCO-2223 and YBCO tapes were subjected to burnout tests in a liquid-nitrogen bath to observe operational stability limits when different layers of dielectric tape are added to the sample surface. In this study, the BSCCO tapes were composed of a silver/alloy sheath with nickel/copper plating, while the YBCO tapes had a 50-μm layer of copper attached to the silver surface. After attaching the tapes to a thermally insulated G-10 holder, the stability of the tapes was found by applying current greater than the critical current and holding it constant for up to 1 min. If the sample voltage increased rapidly during this period, the tape was considered unstable at this current. This was repeated at different layers of Cryoflex™, and the results were compared to a numerical simulation of the energy balance equation. This simulation was also utilized to investigate the effect of the layers on the stability limit and estimate the thermal conductivity of the Cryoflex™.

  14. Comparison of TVT and TVT-O in patients with stress urinary incontinence: short-term cure rates and factors influencing the outcome. A prospective randomised study.

    PubMed

    Karateke, Ates; Haliloglu, Berna; Cam, Cetin; Sakalli, Mustafa

    2009-02-01

    Recently, mid-urethral slings have been commonly used in treatment of patients with stress urinary incontinence (SUI). To investigate tension-free vaginal tape (TVT) and tension-free obturator tape (TVT-O) for surgical treatment of SUI for cure rates (primary endpoint), complications and factors influencing cure rate (secondary endpoints). One-hundred and sixty-four patients were included in the study (n = 81 for TVT, n = 83 for TVT-O). The cure rates, complications, preoperative and postoperative urodynamic evaluation, Q-tip test, the Turkish version of Incontinence Impact Questionnaire (IIQ-7) and Urogenital Distress Inventory (UDI-6) scores were recorded. At three and 12 months, the patients were evaluated regarding outcome measures. The cure rates were similar in TVT and TVT-O groups, 88.9% versus 86.7% respectively. Mean operative time was significantly shorter in TVT-O group (P = 0.001). The cure rate was significantly higher in both groups in patients with urethral hypermobility when compared with those with no hypermobility (P = 0.001). The TVT and TVT-O procedures appear to be equally effective for the treatment of SUI. Also, urethral hypermobility seems to be a factor influencing cure rate of mid-urethral slings.

  15. Tape casting and partial melting of Bi-2212 thick films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buhl, D.; Lang, T.; Heeb, B.

    1994-12-31

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 {mu}m. The orientation of the (a,b)-plane of the grains were parallel to the substrate with a misalignment of less than 6{degrees}. At 77K/OT a critical current density ofmore » 15`000 A/cm{sup 2} was reached in films of the dimension 1cm x 2cm x 20{mu}m (1{mu}V/cm criterion, resistively measured). At 4K/OT the highest value was 350`000 A/cm{sup 2} (1nV/cm criterion, magnetically measured).« less

  16. Flux pinning in nanoparticle doped MgB 2/Cu tapes

    NASA Astrophysics Data System (ADS)

    Babić, E.; Kušević, I.; Husnjak, O.; Soltanian, S.; Wang, X. L.; Dou, S. X.

    2007-09-01

    The irreversibility fields Birr and critical current densities Jc of undoped and Si and SiC nanoparticle doped (5, 10 and 20 wt%) MgB2 tapes were measured in the temperature (T) range 2-38 K and in magnetic fields B ⩽ 16 T. Whereas Birr of undoped tapes varies smoothly with T, those of doped tapes show a change in slope around a crossover field Bcr which increases with nanoparticle content and also depends on their type. This indicates matching effect in vortex pinning, probably associated with Mg2Si nanoprecipitates formed during heat treatment. Indeed, Birr of doped tapes was enhanced in respect to that of undoped one with the highest enhancement for Birr ≈ Bcr, but the enhancement remained high ≈1.4 even for Birr ≫ Bcr (low temperatures). The variations of Jc and the pinning force density Fp = JcB with B and T support the above findings.

  17. Tape casting and partial melting of Bi-2212 thick films

    NASA Technical Reports Server (NTRS)

    Buhl, D.; Lang, TH.; Heeb, B.; Gauckler, L. J.

    1995-01-01

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 microns. The orientation of the (a,b)-plane of the grains was parallel to the substrate with a misalignment of less than 6 deg. At 77 K/0T a critical current density of 15, 000 A/sq cm was reached in films of the dimension 1 cm x 2 cm x 20 microns (1 micron V/cm criterion, resistively measured). At 4 K/0T the highest value was 350,000 A/sq cm (1 nV/cm criterion, magnetically measured).

  18. Generation and physical characteristics of the Landsat 1 and 2 MSS computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1975-01-01

    The generation and format is discussed of the Landsat 1 and 2 system corrected multispectral scanner computer compatible tapes. Included in the discussion are the spacecraft sensors, scene characteristics, the transmission of data, and the conversion of the data to computer compatible tapes at the NASA Data Processing Facility. Geometric and radiometric corrections, tape formats, and the physical characteristics of the tape are also described.

  19. 32 CFR 2402.4 - Procedure for requesting records.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 6 2014-07-01 2014-07-01 false Procedure for requesting records. 2402.4 Section 2402.4 National Defense Other Regulations Relating to National Defense OFFICE OF SCIENCE AND TECHNOLOGY... can be downloaded or transferred intact to a floppy disk, computer disk (CD), tape, or other...

  20. Evolution of oral cancer treatment in an andalusian population sample: Rehabilitation with prosthetic obturation and removable partial prosthesis

    PubMed Central

    Flores-Ruiz, Rafael; Castellanos-Cosano, Lizette; Serrera-Figallo, María-Angeles; Gutiérrez-Corrales, Aida; Gonzalez-Martin, Maribel; Gutiérrez-Pérez, Jose-Luis

    2017-01-01

    Background Radical surgical resection as a treatment modality for oral cancer often leads to an extensive deficit in both the maxillary and mandibular levels, where the use of a palatal obturator prosthesis (POP) or removable partial denture (RPP). The aim of this study was to evaluate the treatment with POP and RPP in patients treated for oral cancer in the Unit of Prosthetic Rehabilitation of the University Hospital Virgen del Rocío in a period of 20 years. Material and Methods Retrospective descriptive study during the years 1991 and 2011 analyzing oral cancer type, characteristics, treatment and follow-up. The sample consisted of patients whose tumor had previously been removed and who had been referred to the Oncological Rehabilitation Unit of the Oral and Maxillofacial Surgery Unit of the “Virgen del Rocío” University Hospital for rehabilitation. The inclusion criteria were patients whose underlying pathology was any type of neoplasia, which after its treatment had been referred to the aforementioned Oncological Prosthetic Rehabilitation unit. Results Of the 45 patients included in our study, 15 patients were rehabilitated with palatal obturator (33.3%) and 5 patients with removable partial denture (11.1%). The mean age of the sample of patients with POP was 57.3 ± 9.23, while the mean age of the sample of patients with RPP was 58 ± 13.5. The most common underlying pathology in patients with POP was squamous cell carcinoma (60%), whereas in patients with RPP it was 100%. The most frequent location found among POP patients was the upper jaw, while in the PRP patients there was no predominant location. The univariate and multivariate logistic regressions did not show any statistically significant association between the independent variables age, sex, smoking habit and alcoholic habit with the dependent variable type of rehabilitating prosthesis. Conclusions Based on our data, we can conclude that RPP is used in few cases of oncological rehabilitation

  1. Evolution of oral cancer treatment in an andalusian population sample: Rehabilitation with prosthetic obturation and removable partial prosthesis.

    PubMed

    Flores-Ruiz, Rafael; Castellanos-Cosano, Lizette; Serrera-Figallo, María-Angeles; Gutiérrez-Corrales, Aida; Gonzalez-Martin, Maribel; Gutiérrez-Pérez, Jose-Luis; Torres-Lagares, Daniel

    2017-08-01

    Radical surgical resection as a treatment modality for oral cancer often leads to an extensive deficit in both the maxillary and mandibular levels, where the use of a palatal obturator prosthesis (POP) or removable partial denture (RPP). The aim of this study was to evaluate the treatment with POP and RPP in patients treated for oral cancer in the Unit of Prosthetic Rehabilitation of the University Hospital Virgen del Rocío in a period of 20 years. Retrospective descriptive study during the years 1991 and 2011 analyzing oral cancer type, characteristics, treatment and follow-up. The sample consisted of patients whose tumor had previously been removed and who had been referred to the Oncological Rehabilitation Unit of the Oral and Maxillofacial Surgery Unit of the "Virgen del Rocío" University Hospital for rehabilitation. The inclusion criteria were patients whose underlying pathology was any type of neoplasia, which after its treatment had been referred to the aforementioned Oncological Prosthetic Rehabilitation unit. Of the 45 patients included in our study, 15 patients were rehabilitated with palatal obturator (33.3%) and 5 patients with removable partial denture (11.1%). The mean age of the sample of patients with POP was 57.3 ± 9.23, while the mean age of the sample of patients with RPP was 58 ± 13.5. The most common underlying pathology in patients with POP was squamous cell carcinoma (60%), whereas in patients with RPP it was 100%. The most frequent location found among POP patients was the upper jaw, while in the PRP patients there was no predominant location. The univariate and multivariate logistic regressions did not show any statistically significant association between the independent variables age, sex, smoking habit and alcoholic habit with the dependent variable type of rehabilitating prosthesis. Based on our data, we can conclude that RPP is used in few cases of oncological rehabilitation. The POP has a greater use, as long as the defect in the

  2. JPL Ephemeris Tapes E9510, E9511, and E9512

    NASA Technical Reports Server (NTRS)

    Peabody, P. R.; Scott, J. F.; Orozco, E. G.

    1964-01-01

    The first issue of JPL Ephemeris Tapes is described. These tapes carry the positions and velocities of the planets and of the Moon, plus nutations and nutation rates in longitude and obliquity, together with second and fourth modified differences, for the interval December 30, 1949, to January 5, 2000.

  3. Texture analysis of T1-w and T2-w MR images allows a quantitative evaluation of radiation-induced changes of internal obturator muscles after radiotherapy for prostate cancer.

    PubMed

    Scalco, Elisa; Rancati, Tiziana; Pirovano, Ileana; Mastropietro, Alfonso; Palorini, Federica; Cicchetti, Alessandro; Messina, Antonella; Avuzzi, Barbara; Valdagni, Riccardo; Rizzo, Giovanna

    2018-04-01

    To investigate the potential of texture analysis applied on T2-w and postcontrast T1-w images acquired before radiotherapy for prostate cancer (PCa) and 12 months after its completion in quantitatively characterizing local radiation effect on the muscular component of internal obturators, as organs potentially involved in urinary toxicity. T2-w and postcontrast T1-w MR images were acquired at 1.5 T before treatment (MRI1) and at 12 months of follow-up (MRI2) in 13 patients treated with radiotherapy for PCa. Right and left internal obturator muscle contours were manually delineated upon MRI1 and then automatically propagated on MRI2 by an elastic registration method. Planning CT images were coregistered to both MRIs and dose maps were deformed accordingly. A high-dose region receiving >55 Gy and a low-dose region receiving <55 Gy were identified in each muscle volume. Eighteen textural features were extracted from each region of interest and differences between MRI1 and MRI2 were evaluated. A signal increase was highlighted in both T2-w and T1-w images in the portion of the obturators near the prostate, i.e., in the region receiving medium-high doses. A change in the spatial organization was identified, as an increase in homogeneity and a decrease in contrast and complexity, compatible with an inflammatory status. In particular, the region receiving medium-high doses presented more significant or, at least, stronger differences. Texture analysis applied on T1-w and T2-w MR images has demonstrated its ability in quantitative evaluating radiation-induced changes in obturator muscles after PCa radiotherapy. © 2018 American Association of Physicists in Medicine.

  4. FP core carrier technique: thermoplasticized gutta-percha root canal obturation technique using polypropylene core.

    PubMed

    Kato, Hiroshi; Nakagawa, Kan-Ichi

    2010-01-01

    Core carrier techniques are unique among the various root canal filling techniques for delivering and compacting gutta-percha in the prepared root canal system. Thermafil (TF), considered the major core carrier device, is provided as an obturator consisting of a master core coated with thermoplasticized gutta-percha. We have devised a thermoplasticized gutta-percha filling technique using a polypropylene core, FlexPoint® NEO (FP), which was developed as a canal filling material that can be sterilized in an autoclave. Therefore, FP can be coated onto thermoplasticized gutta-percha and inserted into the prepared canal as a core carrier. The FP core carrier technique offers many advantages over the TF system: the core can be tested in the root canal and verified radiographically; the core can be adjusted to fit and surplus material easily removed; furthermore the core can be easily removed for retreatment. The clinical procedure of the FP core carrier technique is simple, and similar that with the TF system. Thermoplasticized gutta-percha in a syringe is heated in an oven and extruded onto the FP core carrier after a trial insertion. The FP core carrier is inserted into the root canal to the working length. Excess FP is then removed with a red-hot plastic instrument at the orifice of the root canal. The FP core carrier technique incorporates the clinical advantages of the existing TF system while minimizing the disadvantages. Hence the FP core carrier technique is very useful in clinical practice. This paper describes the FP core carrier technique as a new core based method.

  5. High current density electropolishing in the preparation of highly smooth substrate tapes for coated conductors

    DOEpatents

    Kreiskott, Sascha [Los Alamos, NM; Matias, Vladimir [Santa Fe, NM; Arendt, Paul N [Los Alamos, NM; Foltyn, Stephen R [Los Alamos, NM; Bronisz, Lawrence E [Los Alamos, NM

    2009-03-31

    A continuous process of forming a highly smooth surface on a metallic tape by passing a metallic tape having an initial roughness through an acid bath contained within a polishing section of an electropolishing unit over a pre-selected period of time, and, passing a mean surface current density of at least 0.18 amperes per square centimeter through the metallic tape during the period of time the metallic tape is in the acid bath whereby the roughness of the metallic tape is reduced. Such a highly smooth metallic tape can serve as a base substrate in subsequent formation of a superconductive coated conductor.

  6. The Influence of the Tape-Recorder on Attainment in EFL.

    ERIC Educational Resources Information Center

    Al-Ansari, Saif; Wigzell, Roy

    1996-01-01

    Reports a study undertaken in Bahrain secondary schools to assess the contribution of tape recorders to learning outcomes in English as a Second Language (ESL). Findings revealed that students' proficiency correlated significantly with their perception of the frequency and skill with which their teacher use a tape recorder. (20 references)…

  7. 41 CFR 101-26.508-2 - Requisitioning data processing tape not available from Federal Supply Schedule contracts.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... contracts. (a) Requisitions for types of EDP tape and instrumentation tape (wide and intermediate band... is located. (b) Requisitions for all types of EDP tape and instrumentation tape (wide and... and $5,000 for instrumentation tape. However, regardless of the amount involved (including...

  8. Age-of-Air, Tape Recorder, and Vertical Transport Schemes

    NASA Technical Reports Server (NTRS)

    Lin, S.-J.; Einaudi, Franco (Technical Monitor)

    2000-01-01

    A numerical-analytic investigation of the impacts of vertical transport schemes on the model simulated age-of-air and the so-called 'tape recorder' will be presented using an idealized 1-D column transport model as well as a more realistic 3-D dynamical model. By comparing to the 'exact' solutions of 'age-of-air' and the 'tape recorder' obtainable in the 1-D setting, useful insight is gained on the impacts of numerical diffusion and dispersion of numerical schemes used in global models. Advantages and disadvantages of Eulerian, semi-Lagrangian, and Lagrangian transport schemes will be discussed. Vertical resolution requirement for numerical schemes as well as observing systems for capturing the fine details of the 'tape recorder' or any upward propagating wave-like structures can potentially be derived from the 1-D analytic model.

  9. The Ergogenic Effect of Elastic Therapeutic Tape on Stride and Step Length in Fatigued Runners

    PubMed Central

    Ward, John; Sorrels, Kenneth; Coats, Jesse; Pourmoghaddam, Amir; Moskop, JoAnn; Ueckert, Kate; Glass, Amanda

    2014-01-01

    Objective The purpose of this study was to determine if elastic therapeutic tape placed on anterior lower limbs would affect stride and step length in fatigued runners’ gait. Methods Forty-two healthy participants were equally divided into a kinesiology tape group (Rocktape) and a no-tape control group. Participants in both groups underwent a baseline running gait test at 6 mph without tape. After this, participants engaged in an exhaustive lower body fatigue protocol until they reached maximal volitional exhaustion. Participants were then randomized to 1 of 2 interventions: (1) Experimental group, which had kinesiology tape placed under tension on the anterior aspect of their lower limbs bilaterally from the upper thigh to just below the patella, or (2) Control group, which did not receive taping. All participants then engaged in a similar 6-mph running gait postanalysis. Participant’s gait was analyzed for 90 seconds during each test iteration. Researchers used a 2-way repeated-measures analysis of variance considering fatigue (prefatigue, postfatigue) and group (tape, no-tape) as subject factors. Results After the fatigue protocol, the no-tape group demonstrated a significant decrease in step length of 14.2 mm (P = .041) and stride length of 29.4 mm (P = .043). The kinesiology tape group did not demonstrate a significant decline in these gait parameters. Conclusions In this preliminary study, placing elastic therapeutic tape over the anterior lower limbs demonstrated short-term preservation of runner step length and stride length in a fatigued state. PMID:25435835

  10. Evaluation of a new silicone adhesive tape among clinicians caring for patients with fragile or at-risk skin.

    PubMed

    Manriquez, Sonia; Loperfido, Bonnie; Smith, Graham

    2014-04-01

    To evaluate performance of a new silicone tape among clinicians caring for patients with fragile skin. An international, multisite, 2-week-use evaluation. Caregivers (n = 217) from acute care hospitals in the United States, United Kingdom, and France who regularly use tapes on patients with fragile skin. The silicone tape was substituted for current-use gentle tapes for a 2-week trial period. Preuse and postuse questionnaires were collected. The main outcome measure was tape preference. Secondary outcomes included (1) satisfaction with current-use tapes, (2) willingness to replace current-use tapes with silicone tape, (3) performance comparisons between tapes, (4) clinician-reported problems with the silicone tape, and (5) case study information. The sample group consisted of nurses (98.1%), assistants (1.4%), and physicians (0.5%). Hospital units (n = 100) included oncology (31%), medical-surgical (14%), dialysis (12%), infusion/intravenous therapy (16%), critical care (10%), wound care (10%), and other units (7%). Overall preference was 92.0% for the silicone tape, 7.5% for current-use tapes, and 0.5% no preference. Dissatisfaction was 61.2% for current-use tapes, and most clinicians (90.2%) would change to the silicone tape. Evaluators favored (≥71.5%) the silicone tape on 10 performance attributes and on overall performance (91.6%). Most evaluators (75.1%) did not experience problems with the silicone tape, and those who did found problems related to adhesion (77.8%), gentleness (16.0%), and residue (6.2%). These results indicate that the silicone tape fills a performance-expectation gap of current acrylic tapes among users of tapes on patients with fragile or at-risk skin.

  11. Investigation of Ag buffered Ni and Ni-Cr alloys as substrates for the preparation of bismuth superconducting tapes

    NASA Astrophysics Data System (ADS)

    Régnier, P.; Bifulco-Michon, C.; Poissonnet, S.; Martin, H.; Bonnaillie, P.; Giunchi, G.; Legendre, F.

    2002-10-01

    We review and comment on the various requirements that a metallic substrate has to meet to be a good candidate for the fabrication of electrodeposited BSCCO superconducting tapes. We conclude that, in the present state of the art, no metallic substrate is really ideal. Hence we have investigated in detail the use of silver-buffered nickel-based alloys that seem to be a viable alternative to pure silver tape, which is more expensive and less resistant to high temperature. The major difficulty encountered was the occurrence of holes and blisters induced in the silver layers by the oxidation of the nickel underlayer during the heat treatments performed at high temperature in open air, which according to our procedure are required to synthesize high-temperature superconducting tapes. It was found that the liquid phases, transiently present in the process during the synthesis of the precursor phases, infiltrate between the Ag layer and the substrate through these holes and strongly react with the substrate transferring the poisoned element to the superconducting film greatly reducing its superconducting properties. Hence, several routes have been explored to try and suppress hole formation. It was found that pre-oxidizing the substrate at 880 °C for 1 h in open air sufficiently lowers the hole and blister densities to allow us to synthesize good Bi-2212 tapes on pure nickel, but not on Ni80-Cr20 alloys. A much more interesting solution seems to be to pre-anneal the substrate in a hydrogenous atmosphere which permits us to remove blisters and holes.

  12. Use of adhesive surgical tape with the absorbable continuous subcuticular suture.

    PubMed

    Kolt, Jeremy D

    2003-08-01

    The absorbable continuous subcuticular suture is frequently used to close surgical incisions where the aim is healing by primary intention. A form of adhesive surgical tape is commonly also placed over the wound but this combination closure seems to have its development based on anecdotal, rather than experimental evidence. The present study reviews the scientific literature on the development of sutureless wound closure and presents the current evidence for the use of combination wound closure. Review was undertaken of the medical literature using the PubMed Internet database and cross-referencing major -articles on the subject. The following combinations of key words were searched: skin closure, wound closure, suture technique, sutureless, adhesive tape, op-site, staples, subcuticular suture, complication, infection and scars. Taped closure alone has advantages of lower wound infection rates and greater wound tensile strength, but disadvantages of epidermal reaction, skin edge inversion, doubtful safety and time required for meticulous surgical technique. The use of the continuous absorbable subcuticular suture allows accurate skin edge approximation, which increases the safety margin. The combination closure has a slightly superior cosmetic result to sutureless techniques but no study has been performed to compare the results of combination subcuticular suture and tape, with tape or subcuticular suture alone. There is no evidence in the scientific literature to justify or support the practice of closing a surgical wound with both subcuticular suture and adhesive surgical tape.

  13. AC losses in horizontally parallel HTS tapes for possible wireless power transfer applications

    NASA Astrophysics Data System (ADS)

    Shen, Boyang; Geng, Jianzhao; Zhang, Xiuchang; Fu, Lin; Li, Chao; Zhang, Heng; Dong, Qihuan; Ma, Jun; Gawith, James; Coombs, T. A.

    2017-12-01

    This paper presents the concept of using horizontally parallel HTS tapes with AC loss study, and the investigation on possible wireless power transfer (WPT) applications. An example of three parallel HTS tapes was proposed, whose AC loss study was carried out both from experiment using electrical method; and simulation using 2D H-formulation on the FEM platform of COMSOL Multiphysics. The electromagnetic induction around the three parallel tapes was monitored using COMSOL simulation. The electromagnetic induction and AC losses generated by a conventional three turn coil was simulated as well, and then compared to the case of three parallel tapes with the same AC transport current. The analysis demonstrates that HTS parallel tapes could be potentially used into wireless power transfer systems, which could have lower total AC losses than conventional HTS coils.

  14. Towards a 1000 tracks digital tape recorder

    NASA Technical Reports Server (NTRS)

    Coutellier, J. M.; Castera, J. P.; Colineau, J.; Lehureau, J. C.; Maurice, F.; Hanna, C.

    1993-01-01

    As the demand for high data rate (up to 1 Gb/s), high density (down to 1 sq micron/bit) tape recorder increases, the main investigation trend is an improvement of the well known helical scan concept. The drawbacks of this technology are also well known; sophisticated mechanics, head to tape contact, and wear problems. In our fixed head approach, the recorder mechanics is made much more simple, but the complexity is turned towards the integrated magnetic components, which have to record and reproduce hundreds of tracks in parallel. Our multiplexed write inductive head and magneto-optical readout head will be described, and the global system performances evaluated.

  15. Is Kinesio Taping to Generate Skin Convolutions Effective for Increasing Local Blood Circulation?

    PubMed Central

    Yang, Jae-Man; Lee, Jung-Hoon

    2018-01-01

    Background It is unclear whether traditional application of Kinesio taping, which produces wrinkles in the skin, is effective for improving blood circulation. This study investigated local skin temperature changes after the application of an elastic therapeutic tape using convolution and non-convolution taping methods (CTM/NCTM). Material/Methods Twenty-eight pain-free men underwent CTM and NCTM randomly applied to the right and left sides of the lower back. Using infrared thermography, skin temperature was measured before, immediately after application, 5 min later, 15 min later, and after the removal of the tape. Results Both CTM and NCTM showed a slight, but significant, decrease in skin temperature for up to 5 min. The skin temperature at 15 min and after the removal of the tape was not significantly different from the initial temperature for CTM and NCTM. There were also no significant differences in the skin temperatures between CTM and NCTM. Conclusions Our findings do not support a therapeutic effect of wrinkling the skin with elastic tape application as a technique to increase local blood flow. PMID:29332101

  16. Is Kinesio Taping to Generate Skin Convolutions Effective for Increasing Local Blood Circulation?

    PubMed

    Yang, Jae-Man; Lee, Jung-Hoon

    2018-01-14

    BACKGROUND It is unclear whether traditional application of Kinesio taping, which produces wrinkles in the skin, is effective for improving blood circulation. This study investigated local skin temperature changes after the application of an elastic therapeutic tape using convolution and non-convolution taping methods (CTM/NCTM). MATERIAL AND METHODS Twenty-eight pain-free men underwent CTM and NCTM randomly applied to the right and left sides of the lower back. Using infrared thermography, skin temperature was measured before, immediately after application, 5 min later, 15 min later, and after the removal of the tape. RESULTS Both CTM and NCTM showed a slight, but significant, decrease in skin temperature for up to 5 min. The skin temperature at 15 min and after the removal of the tape was not significantly different from the initial temperature for CTM and NCTM. There were also no significant differences in the skin temperatures between CTM and NCTM. CONCLUSIONS Our findings do not support a therapeutic effect of wrinkling the skin with elastic tape application as a technique to increase local blood flow.

  17. Integration of altitude and airspeed information into a primary flight display via moving-tape formats

    NASA Technical Reports Server (NTRS)

    Abbott, Terence S.; Steinmetz, George G.

    1987-01-01

    A ground-based aircraft simulation study was conducted to determine the effect on pilot performance of replacing the electromechanical altimeter and airspeed indicators with electronically generated representations integrated into the primary flight display via moving-tape (linear moving scale) formats. Several key factors relating to moving-tape formats were examined during the study: tape centering, secondary (trend) information, and tape orientation. The factor of centering refers to whether the tape was centered about the actual airspeed or altitude or about some defined reference value. Tape orientation refers to whether the values represented are arranged in either descending or ascending order. Six pilots participated in this study, with each subject performing 18 runs along a single, known flight profile. Subjective results indicated that the moving-tape formats were generally better than that of the conventional instruments. They also indicated that an actual-centered fixed pointer was preferred to a reference-centered pointer. Performance data for a visual secondary task showed that formats not containing trend information produced better performance; however, no difference was noted in airspeed tracking or altitude tracking performance. Regarding tape orientation, subjective comments indicated that there was lower work load and better performance when the airspeed tape had the high numbers at the top.

  18. Scan converting video tape recorder

    NASA Technical Reports Server (NTRS)

    Holt, N. I. (Inventor)

    1971-01-01

    A video tape recorder is disclosed of sufficient bandwidth to record monochrome television signals or standard NTSC field sequential color at current European and American standards. The system includes scan conversion means for instantaneous playback at scanning standards different from those at which the recording is being made.

  19. Apical and root canal space sealing abilities of resin and glass ionomer-based root canal obturation systems.

    PubMed

    Royer, Kinga; Liu, Xue Jun; Zhu, Qiang; Malmstrom, Hans; Ren, Yan-Fang

    2013-01-01

    To investigate the apical sealing ability of glass ionomer and resin-based root canal obturation systems in comparison to a conventional vertical compaction of warm guttapercha. Forty-five extracted human teeth were randomly assigned into 3 groups of 15 each: a resin-based (EndoRez), a glass ionomer-based (Activ GP), and a conventional gutta-percha plus pulp sealer obturation system (GP/EWT). Apical and root canal space sealing abilities were assessed on five cross-sections 1.0 mm apart starting from the apex. Cross-section images were analysed using a focus-variation 3D scanning microscope and unsealed space was calculated as the percentage of total root canal space occupied by voids and debris. EndoRez had significantly higher rate of apical leakage and deeper dye penetration as compared to GP/EWT and Activ GP. EndoRez group had also more voids and debris (22.5%) in the root canal spaces as compared to GP/EWT (10.5%) and Activ GP (10.8%). Apical leakages occurred not only along the root canal walls, but also along the gutta-percha cones with EndoRez as a result of significant polymerisation shrinkage of the resin sealer. Resin-based EndoRez did not form an adequate apical seal of filled root canals. Glass ionomer-based Activ GP was comparable to a vertical compaction of warm guttapercha plus EWT sealer in sealing root canal spaces.

  20. Water-vapor effects on friction of magnetic tape in contact with nickel-zinc ferrite

    NASA Technical Reports Server (NTRS)

    Miyoshi, K.; Buckley, D. H.

    1984-01-01

    The effects of humidity of moist nitrogen on the friction and deformation behavior of magnetic tape in contact with a nickel-zinc ferrite spherical pin were studied. The results indicate that the coefficient of friction is markedly dependent on the ambient relative humidity. Although the coefficient of friction remains low below 40-percent relative humidity, it increases rapidly with increasing relative humidity above 40 percent. The general ambient environment of the tape does not have any effect on the friction behavior if the area where the tape is in sliding contact with the ferrite pin is flooded with controlled nitrogen. The response time for the friction of the tape to humidity changes is about 10 sec. The effect of friction as a function of relative humidity on dehumidifying is very similar to that on humidifying. A surface softening of the tape due to water vapor increases the friction of the tape.

  1. Histological dermal changes caused by preparation and application procedures in percutaneous dose toxicity studies in dogs, rabbits and rats

    PubMed Central

    Mitsuishi, Mikio; Oshikata, Takafumi; Kumabe, Shino; Kobayashi, Azusa; Katoku, Koshiro; Kanno, Takeshi; Hamamura, Masao; Tsuchitani, Minoru

    2014-01-01

    We reevaluated histological slides of dorsal skin in control animals from past percutaneous dose toxicity studies using dogs, rabbits and rats to provide background data concerning histological changes related to preparation and application procedures and vehicles or embrocations of every variety. Acanthosis, dermal or perifollicular inflammatory cell infiltration in dogs; hyperkeratosis, acanthosis, dermal inflammatory cell infiltration or hemorrhage in rabbits; and acanthosis, dermal inflammatory cell infiltration, crust or foreign body granuloma in rats were present as procedure-related underlying histological changes in the control animals. Four mechanical acts, (1) rubbing with gauze to remove an administered substance for reapplication, (2) use of a taut bandage to avoid slipping from the application site, (3) peeling a patch off as a preparation procedure for reapplication, and (4) clipping or shaving, were considered to cause injury to the skin. The degree of influence of the various application procedures was found to be as follows: sham, lotion < cream < ointment and tape in dogs; untreated control, sham < lotion < tape and poultice in rabbits; and sham, sodium carboxymethylcellulose < olive oil and lotion < ointment and tape in rats. The degree of ointment influence on rabbits is equivocal. PMID:26023255

  2. Ceramic-metal composites prepared via tape casting and melt infiltration methods

    NASA Astrophysics Data System (ADS)

    Kim, Hyun Jun

    Melt infiltration of preforms prepared by tape casting and lamination has been accomplished using a short-time infiltration process that significantly suppresses reaction product formation. For layered materials produced via infiltration of laminated ceramic tapes, of particular interest is the effect that a large change in microstructure has on infiltration, phase formation, and mechanical properties. Hardness of the fine scale composite layers is approximately three times higher than coarse scale layers, due to greater strength of the fine B4C network. Fractography showed that crack propagation occurred by brittle fracture of the carbide and ductile extension of the metal. Despite large differences in hardness, the fracture mode of the fine and coarse scale microstructures appears identical. Fluid flow modeling for tape casting was conducted with a Newtonian slurry under a parallel blade, and the effect of beveling the blade based on a one dimensional flow model is shown. The discussion on slurry deformation after the blade exit suggests that the mode of slurry deformation depends on the relative importance of the pressure gradient and wall shear and that the existence of zero shear plane might have a negative effect on particle alignment in the tape. The analysis of the flow under a beveled blade predicts that this configuration is more advantageous than the parallel blade for productivity and parallel blade is better for producing uniform particle alignment and thinner tape. Also, the one dimensional flow model for the beveled blade is shown to be a valid approximation of the fluid behavior below a blade angle of 45 degrees. The flow visualization study on tape casting was conducted with a transparent apparatus and model slurry. Most investigators have concluded that the shear stress between the doctor blade and moving carrier causes the particle alignment, but, according to the result of visualization experiment, some degree of particle alignment is already

  3. Evaluation of complications of root canal treatment performed by undergraduate dental students.

    PubMed

    AlRahabi, Mothanna K

    2017-12-01

    This study evaluated the technical quality of root canal treatment (RCT) and detected iatrogenic errors in an undergraduate dental clinic at the College of Dentistry, Taibah University, Saudi Arabia. Dental records of 280 patients who received RCT between 2013 and 2016 undertaken by dental students were investigated by retrospective chart review. Root canal obturation was evaluated on the basis of the length of obturation being ≤2 mm from the radiographic apex, with uniform radiodensity and good adaptation to root canal walls. Inadequate root canal obturation included cases containing procedural errors such as furcal perforation, ledge, canal transportation, strip perforation, root perforation, instrument separation, voids in the obturation, or underfilling or overfilling of the obturation. In 193 (68.9%) teeth, RCT was adequate and without procedural errors. However, in 87 (31.1%) teeth, RCT was inadequate and contained procedural errors. The frequency of procedural errors in the entire sample was 31.1% as follows: underfilling, 49.9%; overfilling, 24.1%; voids, 12.6%; broken instruments, 9.2%; apical perforation, 2.3%; and root canal transportation, 2.3%. There were no significant differences (p > 0.05) in the type or frequency of procedural errors between the fourth- and fifth-year students. Lower molars (43.1%) and upper incisors (19.2%) exhibited the highest and lowest frequencies of procedural errors, respectively. The technical quality of RCT performed by undergraduate dental students was classified as 'adequate' in 68.9% of the cases. There is a need for improvement in the training of students at the preclinical and clinical levels.

  4. Generation and physical characteristics of the LANDSAT-1, -2 and -3 MSS computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1977-01-01

    The generation and format of the LANDSAT 1, 2, and 3 system corrected multispectral scanner computer compatible tapes are discussed. Included in the discussion are the spacecraft sensors, scene characteristics, the transmission of data, and the conversion of the data to computer compatible tapes. Also included in the discussion are geometric and radiometric corrections, tape formats, and the physical characteristics of the tape.

  5. The Goddard helical tape recorder

    NASA Technical Reports Server (NTRS)

    Martin, F. T.; Mccarthy, D. K.

    1972-01-01

    A spacecraft recorder was developed with the objective of functioning continuously for 5 years. The resulting design employed a metallic tape wound in a 200-turn helix. A direct drive, brushless dc torquer and servo speed control drove the recorder at 3 rpm for recording and 54 rpm for playback.

  6. EFFECT OF ATHLETIC TAPING AND KINESIOTAPING® ON MEASUREMENTS OF FUNCTIONAL PERFORMANCE IN BASKETBALL PLAYERS WITH CHRONIC INVERSION ANKLE SPRAINS

    PubMed Central

    Karatas, Nihan; Baltaci, Gul

    2012-01-01

    Background: Chronic inversion ankle sprains are common in basketball players. The effect of taping on functional performance is disputed in the literature. Kinesiotaping® (KT®) is a new method that is being used as both a therapeutic and performance enhancement tool. To date, it appears that no study has investigated the effect of ankle KT® on functional performance. Purpose: To investigate the effects of different types of taping (KT® using Kinesio Tex®, athletic taping) on functional performance in athletes with chronic inversion sprains of the ankle. Study Design: Crossover Study Design Methods: Fifteen male basketball players with chronic inversion ankle sprains between the ages of 18 and 22 participated in this study. Functional performance tests (Hopping test by Amanda et al, Single Limb Hurdle Test, Standing Heel Rise test, Vertical Jump Test, The Star Excursion Balance Test [SEBT] and Kinesthetic Ability Trainer [KAT] Test) were used to quantify agility, endurance, balance, and coordination. These tests were conducted four times at one week intervals using varied conditions: placebo tape, without tape, standard athletic tape, and KT®. One-way ANOVA tests were used to examine difference in measurements between conditions. Bonferroni correction was applied to correct for repeated testing. Results: There were no significant differences among the results obtained using the four conditions for SEBT (anterior p=0.0699; anteromedial p=0.126; medial p=0.550; posteromedial p=0.587; posterior p=0.754; posterolateral p=0.907; lateral p=0.124; anterolateral p=0.963) and the KAT dynamic measurement (p=0.388). Faster performance times were measured with KT® and athletic tape in single limb hurdle test when compared to placebo and non-taped conditions (Athletic taping- placebo taping: p=0.03; athletic taping- non tape p=0.016;KT®- Placebo taping p=0.042; KT®-Non tape p=0.016). In standing heel rise test and vertical jump test, athletic taping led to decreased

  7. Goddard Space Flight Center specification for Helical-Scan 8-millimeter (mm) magnetic digital data tape cartridge

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1992-01-01

    The same kind of standard and controls are established that are currently in use for the procurement of new analog, digital, and IBM/IBM compatible 3480 tape cartridges, and 1 in wide channel video magnetic tapes. The Magnetic Tape Certification Facility (MTCF) maintains a Qualified Products List (QPL) for the procurement of new magnetic media and uses the following specifications for the QPL and Acceptance Tests: (1) NASA TM-79724 is used for the QPL and Acceptance Testing of new analog magnetic tapes; (2) NASA TM-80599 is used for the QPL and Acceptance Testing of new digital magnetic tapes; (3) NASA TM-100702 is used for the QPL and Acceptance Testing of new IBM/IBM compatible 3840 magnetic tape cartridges; and (4) NASA TM-100712 is used for the QPL and Acceptance Testing of new 1 in wide channel video magnetic tapes. This document will be used for the QPL and Acceptance Testing of new Helical Scan 8 mm digital data tape cartridges.

  8. Immediate Effects of Kinesiology Taping of Quadriceps on Motor Performance after Muscle Fatigued Induction.

    PubMed

    Ahn, Ick Keun; Kim, You Lim; Bae, Young-Hyeon; Lee, Suk Min

    2015-01-01

    Objectives. The purpose of this cross-sectional single-blind study was to investigate the immediate effects of Kinesiology taping of quadriceps on motor performance after muscle fatigued induction. Design. Randomized controlled cross-sectional design. Subjects. Forty-five subjects participated in this study. Participants were divided into three groups: Kinesiology taping group, placebo taping group, and nontaping group. Methods. Subjects performed short-term exercise for muscle fatigued induction, followed by the application of each intervention. Peak torque test, one-leg single hop test, active joint position sense test, and one-leg static balance test were carried out before and after the intervention. Results. Peak torque and single-leg hopping distance were significantly increased when Kinesiology taping was applied (p < 0.05). But there were no significant effects on active joint position sense and single-leg static balance. Conclusions. We proved that Kinesiology taping is effective in restoring muscle power reduced after muscle fatigued induction. Therefore, we suggest that Kinesiology taping is beneficial for fatigued muscles.

  9. Effects of functional taping compared with sham taping and minimal intervention on pain intensity and static postural control for patients with non-specific chronic low back pain: a randomised clinical trial protocol.

    PubMed

    Jassi, F J; Del Antônio, T; Moraes, R; George, S Z; Chaves, T C

    2017-06-01

    To investigate the immediate and 1-month effects of functional taping to lumbar spine for pain intensity and postural control in patients with chronic non-specific low back pain. Randomised clinical trial. One hundred and twenty participants aged 18 to 50 years. Participants will be allocated at random to receive one of three interventions: functional star-shape taping for 7 days, sham functional taping for 7 days or minimal intervention, one session. The primary outcomes will be pain intensity and postural control. Four measurements of static posturography will be conducted: pre-intervention, immediately after application of the tape, 7 days post-intervention (after removal of the tape) and 1-month follow-up. The secondary outcomes will be low-back-pain-related disability, global perceived effect of treatment and fear avoidance beliefs. Primary and secondary outcomes will be assessed on three occasions: pre-intervention, 7 days post-intervention and at 1-month follow-up. All statistical analyses will be conducted following intention-to-treat principles, and the treatment effects will be calculated using linear mixed models. The results of this study will determine the effects of functional taping on pain intensity and postural control compared with sham taping and minimal intervention. NCT02546466. Copyright © 2016 Chartered Society of Physiotherapy. All rights reserved.

  10. Effects of low-dye taping on plantar pressure pre and post exercise: an exploratory study.

    PubMed

    Nolan, Damien; Kennedy, Norelee

    2009-04-21

    Low-Dye taping is used for excessive pronation at the subtalar joint of the foot. Previous research has focused on the tape's immediate effect on plantar pressure. Its effectiveness following exercise has not been investigated. Peak plantar pressure distribution provides an indirect representation of subtalar joint kinematics. The objectives of the study were 1) To determine the effects of Low-Dye taping on peak plantar pressure immediately post-application. 2) To determine whether any initial effects are maintained following exercise. 12 asymptomatic subjects participated; each being screened for excessive pronation (navicular drop > 10 mm). Plantar pressure data was recorded, using the F-scan, at four intervals during the testing session: un-taped, baseline-taped, post-exercise session 1, and post-exercise session 2. Each exercise session consisted of a 10-minute walk at a normal pace. The foot was divided into 6 regions during data analysis. Repeated-measures analysis of variance (ANOVA) was used to assess regional pressure variations across the four testing conditions. Reduced lateral forefoot peak plantar pressure was the only significant difference immediately post tape application (p = 0.039). This effect was lost after 10 minutes of exercise (p = 0.036). Each exercise session resulted in significantly higher medial forefoot peak pressure compared to un-taped; (p = 0.015) and (p = 0.014) respectively, and baseline-taped; (p = 0.036) and (p = 0.015) respectively. Medial and lateral rearfoot values had also increased after the second session (p = 0.004), following their non-significant reduction at baseline-taped. A trend towards a medial-to-lateral shift in pressure present in the midfoot immediately following tape application was still present after 20 minutes of exercise. Low-Dye tape's initial effect of reduced lateral forefoot peak plantar pressure was lost after a 10-minute walk. However, the tape continued to have an effect on the medial forefoot after

  11. Thermomechanical Analysis of Shape-Memory Composite Tape Spring

    NASA Astrophysics Data System (ADS)

    Yang, H.; Wang, L. Y.

    2013-06-01

    Intelligent materials and structures have been extensively applied for satellite designs in order to minimize the mass and reduce the cost in the launch of the spacecraft. Elastic memory composites (EMCs) have the ability of high-strain packaging and shape-memory effect, but increase the parts and total weight due to the additional heating system. Shape-memory sandwich structures Li and Wang (J. Intell. Mater. Syst. Struct. 22(14), 1605-1612, 2011) can overcome such disadvantage by using the metal skin acting as the heating element. However, the high strain in the micro-buckled metal skin decreases the deployment efficiency. This paper aims to present an insight into the folding and deployment behaviors of shape-memory composite (SMC) tape springs. A thermomechanical process was analyzed, including the packaging deformation at an elevated temperature, shape frozen at the low temperature and shape recovery after reheating. The result shows that SMC tape springs can significantly decrease the strain concentration in the metal skin, as well as exhibiting excellent shape frozen and recovery behaviors. Additionally, possible failure modes of SMC tape springs were also analyzed.

  12. Methods for tape fabrication of continuous filament composite parts and articles of manufacture thereof

    DOEpatents

    Weisberg, Andrew H

    2013-10-01

    A method for forming a composite structure according to one embodiment includes forming a first ply; and forming a second ply above the first ply. Forming each ply comprises: applying a bonding material to a tape, the tape comprising a fiber and a matrix, wherein the bonding material has a curing time of less than about 1 second; and adding the tape to a substrate for forming adjacent tape winds having about a constant distance therebetween. Additional systems, methods and articles of manufacture are also presented.

  13. NASA Global Atmospheric Sampling Program (GASP) data report for tape VL0006

    NASA Technical Reports Server (NTRS)

    Gauntner, D. J.; Holdeman, J. D.; Humenik, F. M.

    1977-01-01

    The NASA Global Atmospheric Sampling Program (GASP) is obtaining measurements of atmospheric trace constituents in the upper troposphere and lower stratosphere using fully automated air sampling systems on board several commercial B-747 aircraft in routine airline service. Atmospheric ozone, and related flight and meteorological data were obtained during 245 flights of a Qantas Airways of Australia B-747 and two Pan American World Airways B-747s from July 1976 through September 1976. In addition, whole air samples, obtained during three flights, were analyzed for trichlorofluoromethane, and filter samples, obtained during four flights, were analyzed for sulfates, nitrates, fluorides, and chlorides. Flight routes and dates, instrumentation, data processing procedures, data tape specifications, and selected analyses are discussed.

  14. High-Throughput Method of Whole-Brain Sectioning, Using the Tape-Transfer Technique.

    PubMed

    Pinskiy, Vadim; Jones, Jamie; Tolpygo, Alexander S; Franciotti, Neil; Weber, Kevin; Mitra, Partha P

    2015-01-01

    Cryostat sectioning is a popular but labor-intensive method for preparing histological brain sections. We have developed a modification of the commercially available CryoJane tape collection method that significantly improves the ease of collection and the final quality of the tissue sections. The key modification involves an array of UVLEDs to achieve uniform polymerization of the glass slide and robust adhesion between the section and slide. This report presents system components and detailed procedural steps, and provides examples of end results; that is, 20 μm mouse brain sections that have been successfully processed for routine Nissl, myelin staining, DAB histochemistry, and fluorescence. The method is also suitable for larger brains, such as rat and monkey.

  15. High-Throughput Method of Whole-Brain Sectioning, Using the Tape-Transfer Technique

    PubMed Central

    Pinskiy, Vadim; Jones, Jamie; Tolpygo, Alexander S.; Franciotti, Neil; Weber, Kevin; Mitra, Partha P.

    2015-01-01

    Cryostat sectioning is a popular but labor-intensive method for preparing histological brain sections. We have developed a modification of the commercially available CryoJane tape collection method that significantly improves the ease of collection and the final quality of the tissue sections. The key modification involves an array of UVLEDs to achieve uniform polymerization of the glass slide and robust adhesion between the section and slide. This report presents system components and detailed procedural steps, and provides examples of end results; that is, 20μm mouse brain sections that have been successfully processed for routine Nissl, myelin staining, DAB histochemistry, and fluorescence. The method is also suitable for larger brains, such as rat and monkey. PMID:26181725

  16. Short-Term Effects of Kinesio Taping and Cross Taping Application in the Treatment of Latent Upper Trapezius Trigger Points: A Prospective, Single-Blind, Randomized, Sham-Controlled Trial

    PubMed Central

    Słupska, Lucyna; Paprocka-Borowicz, Małgorzata; Taradaj, Jakub; Bidzińska, Gabriela; Marczyński, Daniel; Cynarska, Aleksandra; Rosińczuk, Joanna

    2015-01-01

    Kinesio taping (KT) may be a new treatment in patients with myofascial trigger points (MTrPs). A new method available for taping practitioners is cross taping (CT). The main objective was to determine how CT, KT, and medical adhesive tape (sham group) affect the subjective assessment of resting bioelectrical activity and pain of the upper trapezius muscle (UT) in patients with MTrPs. 105 volunteers were recruited to participate. The primary outcome was resting bioelectrical activity of UT muscle as assessed by surface electromyography (sEMG) in each group and pain intensity on a visual analog scale (VAS). Assessments were collected before and after intervention and after the 24-hours follow-up. No significant differences were observed in bioelectrical activity of UT between pre-, post-, and follow-up results. In three groups patients had significantly lower pain VAS score after the intervention (CT—p < 0.001, KT—p < 0.001, and sham—p < 0.01). The Kruskal-Wallis ANOVA showed no significant differences in almost all measurements between groups. The application of all three types of tapes does not influence the resting bioelectrical activity of UT muscle and may not lead to a reduction in muscle tone in the case of MTrPs. PMID:26491458

  17. VIEW OF CABLES AND TAPES ASSOCIATED WITH ADRIVE CONTROL ROD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF CABLES AND TAPES ASSOCIATED WITH A-DRIVE CONTROL ROD SYSTEM, AT LEVEL +15’, DIRECTLY ABOVE PDP CONTROL ROOM, LOOKING NORTHWEST. THE CABLES FROM THE PDP ROOM GO THROUGH THE CONCRETE WALL, MAKE A RIGHT ANGLE TURN DOWNWARD, AND DESCEND INTO THE PDP CONTROL ROOM AS VERTICAL TAPES - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  18. Performance measurements and operational characteristics of the Storage Tek ACS 4400 tape library with the Cray Y-MP EL

    NASA Technical Reports Server (NTRS)

    Hull, Gary; Ranade, Sanjay

    1993-01-01

    With over 5000 units sold, the Storage Tek Automated Cartridge System (ACS) 4400 tape library is currently the most popular large automated tape library. Based on 3480/90 tape technology, the library is used as the migration device ('nearline' storage) in high-performance mass storage systems. In its maximum configuration, one ACS 4400 tape library houses sixteen 3480/3490 tape drives and is capable of holding approximately 6000 cartridge tapes. The maximum storage capacity of one library using 3480 tapes is 1.2 TB and the advertised aggregate I/O rate is about 24 MB/s. This paper reports on an extensive set of tests designed to accurately assess the performance capabilities and operational characteristics of one STK ACS 4400 tape library holding approximately 5200 cartridge tapes and configured with eight 3480 tape drives. A Cray Y-MP EL2-256 was configured as its host machine. More than 40,000 tape jobs were run in a variety of conditions to gather data in the areas of channel speed characteristics, robotics motion, time taped mounts, and timed tape reads and writes.

  19. User's guide to the UTIL-ODRC tape processing program. [for the Orbital Data Reduction Center

    NASA Technical Reports Server (NTRS)

    Juba, S. M. (Principal Investigator)

    1981-01-01

    The UTIL-ODRC computer compatible tape processing program, its input/output requirements, and its interface with the EXEC 8 operating system are described. It is a multipurpose orbital data reduction center (ODRC) tape processing program enabling the user to create either exact duplicate tapes and/or tapes in SINDA/HISTRY format. Input data elements for PRAMPT/FLOPLT and/or BATCH PLOT programs, a temperature summary, and a printed summary can also be produced.

  20. Kinesio taping in musculoskeletal pain and disability that lasts for more than 4 weeks: is it time to peel off the tape and throw it out with the sweat? A systematic review with meta-analysis focused on pain and also methods of tape application.

    PubMed

    Lim, Edwin Choon Wyn; Tay, Mathew Guo Xiang

    2015-12-01

    In recent years, Kinesio tape has been used to support injured muscle and joints, and relieve pain. We compared the pain and disability in individuals with chronic musculoskeletal pain who were treated with Kinesio taping with those using minimal or other treatment approaches. Searches of eight major electronic databases were conducted. Data for pain and disability scores were extracted. Meta-analyses (wherever possible) with either a fixed or random effect(s) model, standardised mean differences (SMDs) and tests of heterogeneity were performed. Seventeen clinical-controlled trials were identified and included in the meta-analyses. When compared to minimal intervention, Kinesio taping provided superior pain relief (pooled SMD=-0.36, 95% CI -0.64 to -0.09, p=0.009) but the pooled disability scores were not significantly different (pooled SMD=-0.41, 95% CI -0.83 to 0.01, p=0.05). No significant differences were found when comparing Kinesio taping to other treatment approaches for pain (pooled SMD=-0.44, 95% CI -1.69 to 0.82, p=0.49) and disability (pooled SMD=0.08, 95% CI -0.27 to 0.43, p=0.65). Kinesio taping is superior to minimal intervention for pain relief. Existing evidence does not establish the superiority of Kinesio taping to other treatment approaches to reduce pain and disability for individuals with chronic musculoskeletal pain. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. Laser-plasma interactions from thin tapes for high-energy electron accelerators and seeding compact FELs

    NASA Astrophysics Data System (ADS)

    Shaw, Brian Henry

    This thesis comprises a detailed investigation of the physics of using a plasma mirror (PM) from a tape by reflecting ultrashort pulses from a laser-triggered surface plasma. The tapes used in the characterization of the PM are VHS and computer data storage tape. The tapes are 6.6 m (computer storage tape) and 15 m (VHS) thick. Each tape is 0.5 inches wide, and 10s of meters of tape are spooled using a tape drive; providing thousands of shots on a single reel of tape. The amount of reflected energy of the PM was studied for different input intensities. The fluence was varied by translating the focus of the laser upstream and downstream of the tape, which changed the spot size on the tape surface and hence changed the fluence. This study measured reflectances from both sides of the two tapes, and for input light of both s and p-polarizations. Lastly, an analytic model was developed to understand the reflectance as a function of fluence for each tape material and polarization. Another application that benefits from the advancements of LPA technology is an LPAbased FEL. By sending a high quality electron bunch through an undulator (a periodic structure of positive and negative magnetic poles), the electrons oscillate transversely to the propagation axis and produce radiation. The 1.5 m THUNDER undulator at the BELLA Center has been commissioned using electron beams of 400MeV beams with broad energy spread (35%). To produce a coherent LPA-based FEL, the beam quality would need to improve to sub-percent level energy spread. A seed source could be used to help induce bunching of the electron beam within the undulator. This thesis described the experimental investigation of the physics of using solid-based surface high-harmonic generation (SHHG) from a thin tape as a possible seed source for an FEL. A thin tape placed within centimeters of the undulator's entrance could act as a harmonic generating source, while simultaneously transmitting an electron beam. This removes

  2. 36 CFR 1275.64 - Reproduction of tape recordings of Presidential conversations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Reproduction of tape... § 1275.64 Reproduction of tape recordings of Presidential conversations. (a) To ensure the preservation... locations established by the Archivist in accordance with § 1275.62. (d) The reproduction for members of the...

  3. 36 CFR 1275.64 - Reproduction of tape recordings of Presidential conversations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Reproduction of tape... § 1275.64 Reproduction of tape recordings of Presidential conversations. (a) To ensure the preservation... locations established by the Archivist in accordance with § 1275.62. (d) The reproduction for members of the...

  4. Design study for multi-channel tape recorder system, volume 1

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The means of storing multispectral, high resolution sensor data on an Earth observing satellite are studied. It is concluded that this is best done digitally on a multi-track, longitudinal, magnetic tape recorder. The machine proposed will store 8 X 10 to the 10th power bits of data on 1040 m of 51 mm-wide magnetic tape mounted on two co-planar reels.

  5. High rate of vaginal erosions associated with the mentor ObTape.

    PubMed

    Yamada, Brian S; Govier, Fred E; Stefanovic, Ksenija B; Kobashi, Kathleen C

    2006-08-01

    The transobturator tape method is a newer surgical technique for the treatment of stress urinary incontinence. Limited data exist related to complications with this approach or the types of mesh products used. We report our experience with vaginal erosions associated with the Mentor ObTape and American Medical Systems Monarc transobturator slings. Beginning in December 2003 selected female patients with anatomic urinary incontinence were prospectively followed after placement of the Mentor ObTape. Beginning in January 2004 we also began using the American Medical Systems Monarc in similar patients. Patients were admitted overnight after surgery, discharged on oral antibiotics, and seen in the clinic at 6 weeks postoperatively. A total of 67 patients have undergone placement of the Mentor ObTape and 9 of those patients (13.4%) have had vaginal extrusions of the sling. Eight patients reported a history of persistent vaginal discharge. One patient presented initially to an outside facility with a left thigh abscess tracking to the left inguinal incision site. Each patient was taken back to the operating room for mesh removal. A total of 56 patients have undergone placement of the AMS Monarc and none have had any vaginal erosions. Our high rate of vaginal extrusion using the ObTape has led us to discontinue the use of this product in our institution. Continued followup of all of these patients will be of critical importance.

  6. Design optimization of superconducting coils based on asymmetrical characteristics of REBCO tapes

    NASA Astrophysics Data System (ADS)

    Hong, Zhiyong; Li, Wenrong; Chen, Yanjun; Gömöry, Fedor; Frolek, Lubomír; Zhang, Min; Sheng, Jie

    2018-07-01

    Angle dependence Ic(B,θ) of superconducting tape is a crucial parameter to calculate the influence of magnetic field during the design of superconducting applications,. This paper focuses on the asymmetrical characteristics found in REBCO tapes and further applications based on this phenomenon. This paper starts with angle dependence measurements of different HTS tapes, asymmetrical characteristics are found in some of the testing samples. On basis of this property, optimization of superconducting coils in superconducting motor, transformer and insert magnet is discussed by simulation. Simplified experiments which represent the structure of insert magnet were carried out to prove the validity of numerical studies. Conclusions obtained in this paper show that the asymmetrical property of superconducting tape is quite important in design of superconducting applications, and optimized winding technique based on this property can be used to improve the performance of superconducting devices.

  7. High Fidelity Tape Transfer Printing Based On Chemically Induced Adhesive Strength Modulation

    NASA Astrophysics Data System (ADS)

    Sim, Kyoseung; Chen, Song; Li, Yuhang; Kammoun, Mejdi; Peng, Yun; Xu, Minwei; Gao, Yang; Song, Jizhou; Zhang, Yingchun; Ardebili, Haleh; Yu, Cunjiang

    2015-11-01

    Transfer printing, a two-step process (i.e. picking up and printing) for heterogeneous integration, has been widely exploited for the fabrication of functional electronics system. To ensure a reliable process, strong adhesion for picking up and weak or no adhesion for printing are required. However, it is challenging to meet the requirements of switchable stamp adhesion. Here we introduce a simple, high fidelity process, namely tape transfer printing(TTP), enabled by chemically induced dramatic modulation in tape adhesive strength. We describe the working mechanism of the adhesion modulation that governs this process and demonstrate the method by high fidelity tape transfer printing several types of materials and devices, including Si pellets arrays, photodetector arrays, and electromyography (EMG) sensors, from their preparation substrates to various alien substrates. High fidelity tape transfer printing of components onto curvilinear surfaces is also illustrated.

  8. Delayed latency of peroneal reflex to sudden inversion with ankle taping or bracing.

    PubMed

    Shima, N; Maeda, A; Hirohashi, K

    2005-01-01

    The purpose of the present study was to examine the effects of ankle taping and bracing based on the peroneal reflex in the hypermobile and normal ankle joints with and without history of ankle injury. Thirty-six ankle joints of 18 collegiate American football athletes with and without previous history of injury were studied. The angle of talar tilt (TT) was measured by stress radiograph for classifying normal (TT5 degrees ) ankles. They were tested with taping, bracing, and without any supports as a control. The latency of peroneus longus muscle was measured by a sudden inversion of 25 degrees using surface EMG signals. The results of the present study show no significant three-way Group (hypermobile or normal ankles) by History (previously injured or uninjured ankles) by Condition (control, taping, or bracing) interaction, while Condition main effect was significant (p<0.05). There were significant differences between control (80.8 ms) and taping (83.8 ms, p<0.01), between control and bracing (83.0 ms, p<0.05), but not between taping and bracing (p>0.05). In conclusion, ankle taping and bracing delayed the peroneal reflex latency not only for hypermobile ankles and/or injured ankle joints but also for intact ankle joints.

  9. Multi-Response Parameter Interval Sensitivity and Optimization for the Composite Tape Winding Process.

    PubMed

    Deng, Bo; Shi, Yaoyao; Yu, Tao; Kang, Chao; Zhao, Pan

    2018-01-31

    The composite tape winding process, which utilizes a tape winding machine and prepreg tapes, provides a promising way to improve the quality of composite products. Nevertheless, the process parameters of composite tape winding have crucial effects on the tensile strength and void content, which are closely related to the performances of the winding products. In this article, two different object values of winding products, including mechanical performance (tensile strength) and a physical property (void content), were respectively calculated. Thereafter, the paper presents an integrated methodology by combining multi-parameter relative sensitivity analysis and single-parameter sensitivity analysis to obtain the optimal intervals of the composite tape winding process. First, the global multi-parameter sensitivity analysis method was applied to investigate the sensitivity of each parameter in the tape winding processing. Then, the local single-parameter sensitivity analysis method was employed to calculate the sensitivity of a single parameter within the corresponding range. Finally, the stability and instability ranges of each parameter were distinguished. Meanwhile, the authors optimized the process parameter ranges and provided comprehensive optimized intervals of the winding parameters. The verification test validated that the optimized intervals of the process parameters were reliable and stable for winding products manufacturing.

  10. Multi-Response Parameter Interval Sensitivity and Optimization for the Composite Tape Winding Process

    PubMed Central

    Yu, Tao; Kang, Chao; Zhao, Pan

    2018-01-01

    The composite tape winding process, which utilizes a tape winding machine and prepreg tapes, provides a promising way to improve the quality of composite products. Nevertheless, the process parameters of composite tape winding have crucial effects on the tensile strength and void content, which are closely related to the performances of the winding products. In this article, two different object values of winding products, including mechanical performance (tensile strength) and a physical property (void content), were respectively calculated. Thereafter, the paper presents an integrated methodology by combining multi-parameter relative sensitivity analysis and single-parameter sensitivity analysis to obtain the optimal intervals of the composite tape winding process. First, the global multi-parameter sensitivity analysis method was applied to investigate the sensitivity of each parameter in the tape winding processing. Then, the local single-parameter sensitivity analysis method was employed to calculate the sensitivity of a single parameter within the corresponding range. Finally, the stability and instability ranges of each parameter were distinguished. Meanwhile, the authors optimized the process parameter ranges and provided comprehensive optimized intervals of the winding parameters. The verification test validated that the optimized intervals of the process parameters were reliable and stable for winding products manufacturing. PMID:29385048

  11. Effect of athletic taping and kinesiotaping® on measurements of functional performance in basketball players with chronic inversion ankle sprains.

    PubMed

    Bicici, Seda; Karatas, Nihan; Baltaci, Gul

    2012-04-01

    Chronic inversion ankle sprains are common in basketball players. The effect of taping on functional performance is disputed in the literature. Kinesiotaping® (KT®) is a new method that is being used as both a therapeutic and performance enhancement tool. To date, it appears that no study has investigated the effect of ankle KT® on functional performance. To investigate the effects of different types of taping (KT® using Kinesio Tex®, athletic taping) on functional performance in athletes with chronic inversion sprains of the ankle. Crossover Study Design Fifteen male basketball players with chronic inversion ankle sprains between the ages of 18 and 22 participated in this study. Functional performance tests (Hopping test by Amanda et al, Single Limb Hurdle Test, Standing Heel Rise test, Vertical Jump Test, The Star Excursion Balance Test [SEBT] and Kinesthetic Ability Trainer [KAT] Test) were used to quantify agility, endurance, balance, and coordination. These tests were conducted four times at one week intervals using varied conditions: placebo tape, without tape, standard athletic tape, and KT®. One-way ANOVA tests were used to examine difference in measurements between conditions. Bonferroni correction was applied to correct for repeated testing. There were no significant differences among the results obtained using the four conditions for SEBT (anterior p=0.0699; anteromedial p=0.126; medial p=0.550; posteromedial p=0.587; posterior p=0.754; posterolateral p=0.907; lateral p=0.124; anterolateral p=0.963) and the KAT dynamic measurement (p=0.388). Faster performance times were measured with KT® and athletic tape in single limb hurdle test when compared to placebo and non-taped conditions (Athletic taping- placebo taping: p=0.03; athletic taping- non tape p=0.016;KT®- Placebo taping p=0.042; KT®-Non tape p=0.016). In standing heel rise test and vertical jump test, athletic taping led to decreased performance. (Standing heel rise test: Athletic taping

  12. Niobium-germanium superconducting tapes for high-field magnet applications

    NASA Technical Reports Server (NTRS)

    Braginski, A. I.; Roland, G. W.; Daniel, M. R.; Woolam, J. A.

    1977-01-01

    A process of fabricating superconducting Nb3Ge tapes by chemical vapor deposition (CVD) has been developed and tapes up to 10 meters long fabricated. The typical properties achieved were: critical temperature T sub c = 20 K, upper critical field H sub c2 = 29 tesla at 4.2 K, and J sub c = 3 to 4 x 10 to the 8th power A m(-2) at 4.2 K, 18 tesla. The relative depression of T sub c and H sub c2 compared with the best thin film samples sputtered on sapphire was due to the presence of Nb5Ge3 second-phase particles used as flux pinning centers and to strains induced by thermal mixmatch with Hastelloy B tape substrates. A peculiar field dependence of flux pinning force that was observed in both CVD and sputtered Nb3Ge indicated a premature pin-breaking mechanism or a phase inhomogeneity. Directions of further optimization work were defined.

  13. Conductive sub-layer of twisted-tape-induced swirl-flow heat transfer in vertical circular tubes with various twisted-tape inserts

    NASA Astrophysics Data System (ADS)

    Hata, K.; Fukuda, K.; Masuzaki, S.

    2018-04-01

    Twisted-tape-induced swirl-flow heat transfer due to exponentially increasing heat inputs with various exponential periods ( Q = Q 0 exp(t/τ), τ = 6.04 to 23.07 s) and twisted-tape-induced pressure drop was systematically measured for various mass velocities ( G = 4115 to 13,656 kg/m2 s), inlet liquid temperatures ( T in = 285.88 to 299.09 K), and inlet pressures ( P in = 847.45 to 943.29 kPa) using an experimental water loop flow. Measurements were made over a 59.2-mm effective length and three sections (upper, middle, and lower positions), within which four potential taps were spot-welded onto the outer surface of a 6-mm-inner-diameter, 69.6-mm-heated length, 0.4-mm-thickness platinum circular test tube. Type SUS304 twisted tapes with a width w = 5.6 mm, a thickness δ T = 0.6 mm, a total length l = 372 mm, and twist ratios y = 2.39 and 4.45 were employed in this study. The RANS equations (Reynolds Averaged Navier-Stokes Simulation) with a k-ɛ turbulence model for a circular tube 6 mm in diameter and 636 mm in length were numerically solved for heating of water with a heated section 6 mm in diameter and 70 mm in length using the CFD code, under the same conditions as the experimental ones and considering the temperature dependence of the thermo-physical properties concerned. The theoretical values of surface heat flux q on the circular tubes with twisted tapes with twist ratios y of 2.39 and 4.45 were found to be almost in agreement with the corresponding experimental values of heat flux q, with deviations of less than 30% for the range of temperature difference between the average heater inner surface temperature and the liquid bulk mean temperature ΔT L [ = T s,av - T L , T L = ( T in + T out )/2] considered in this study. The theoretical values of the local surface temperature T s , local average liquid temperature T f,av , and local liquid pressure drop ΔP x were found to be within almost 15% of the corresponding experimental ones. The thickness of the

  14. Optimal compliance for amblyopia therapy: occlusion with a translucent tape on the lens.

    PubMed

    Beneish, Raquel G; Polomeno, Robert C; Flanders, Michael E; Koenekoop, Robert K

    2009-10-01

    To demonstrate that optimal compliance to amblyopia therapy and a better visual outcome can be achieved by occluding the lens over the preferred eye with a translucent tape. Prospective study of amblyopic children. Eighty-four amblyopic children recruited from 2000 to 2006 at the Montreal Children's Vision Centre. A group of bilateral ametropes (mean age 3.8 years) were treated with glasses and occlusion of the sound eye with a translucent tape on the lens over the preferred eye, or an adhesive patch. The translucent tape reduced vision to hand motion at 0.3 m in the sound eye. Patients were divided into 2 groups depending on the treatment received. Group 1 (n = 36) was occluded with a translucent tape, and group 2 (n = 48) with a conventional adhesive patch, later replaced by the translucent tape. Twenty-five previously reported patients, treated with the conventional adhesive patch only, were used as controls (group 3). The mean amblyopic visual acuity was 20/100-2. Compliance was good in 36 patients (group 1), and was poor or deteriorated in 24/48 patients (group 2). Substituting the adhesive patch with a translucent tape permitted uninterrupted and prolonged occlusion, with a successful visual outcome. The amblyopic eye achieved a significantly better final vision (20/30+2; groups 1+2) than the controls (20/40+1; group 3) (p = 0.04). Sixty-four (76.19%) patients achieved >or=20/30. The translucent tape optimizes compliance and yields better vision by lengthening the duration of occlusion therapy and reducing the number of treatment failures due to noncompliance.

  15. "Space slitter" for film or tape

    NASA Technical Reports Server (NTRS)

    Johnson, W. H.

    1978-01-01

    Device cuts film or tape into strips by guiding film in channel under cutting blades. Device is operated by lifting pressure bar to insert blades into film. Film is then pulled through blades. Cutter has potential uses in advertising, commercial art, and publishing fields.

  16. The Effect of Patellar Taping on Squat Depth and the Perception of Pain in People with Anterior Knee Pain

    PubMed Central

    Clifford, Amanda M.; Harrington, Elaine

    Patellar taping is a treatment adjunct commonly used in the management of anterior knee pain. The aim of this cross sectional study was to investigate the effects of medial glide patellar taping on sagittal plane lower-limb joint kinematics and knee pain during a unilateral squat in a symptomatic population complaining of anterior knee pain. Ten participants with a history of unilateral or bilateral anterior knee pain were included in the study. Subjects were required to squat on the symptomatic leg under three conditions: placebo tape, patellar tape and no tape. Kinematic data was recorded using the CODA mpx64 motion analysis system and subjects’ pain was assessed using the Numerical Rating Scale. Patellar taping resulted in a significantly greater single-legged squat depth compared to placebo tape (p=0.008) and no tape (p=0.001) and a statistically significant reduction in pain during a squat compared to placebo tape (p=0.001) or no tape (p=0.001). Significant differences were not identified for maximum knee flexion in the patella taping compared to the no tape condition. This study may have significant clinical implications as participants reported less pain and alterations in sagittal plane movement following the application of patellar tape. PMID:24146711

  17. Synchronisation Technique of Data Recorded on a Multichannel Tape Recorder,

    DTIC Science & Technology

    1984-01-01

    retrieval Synchronizers I 16. Abstract A portable, self-contained, electronic digital unit, termed Data Synchroniser was designed and developed by EDE...AD A139 570 SYNCHRONISATION TECHNIQUE OF DATA RECORDED ON A / OULl ICHANNEL TAPE RECORDER (U) ENGINEERING DEVELOPMENT ESTA B LISHMENT MARIBYRNONO...BGINEERING DEVELOPMEWIT ESTABUSHIMENT S[ SYNCHRONISATION TECHNIQUE OF DATA - i RECORDED ON A MULTICHANNEL TAPE RECORDER BY J.D. DICKENS .t T)TCi j.D. ~c .s

  18. Apparatus and method for loading and unloading multiple digital tape cassettes utilizing a removable magazine

    DOEpatents

    Lindenmeyer, C.W.

    1993-01-26

    An apparatus and method to automate the handling of multiple digital tape cassettes for processing by commercially available cassette tape readers and recorders. A removable magazine rack stores a plurality of tape cassettes, and cooperates with a shuttle device that automatically inserts and removes cassettes from the magazine to the reader and vice-versa. Photocells are used to identify and index to the desired tape cassette. The apparatus allows digital information stored on multiple cassettes to be processed without significant operator intervention.

  19. Apparatus and method for loading and unloading multiple digital tape cassettes utilizing a removable magazine

    DOEpatents

    Lindenmeyer, Carl W.

    1993-01-01

    An apparatus and method to automate the handling of multiple digital tape cassettes for processing by commercially available cassette tape readers and recorders. A removable magazine rack stores a plurality of tape cassettes, and cooperates with a shuttle device that automatically inserts and removes cassettes from the magazine to the reader and vice-versa. Photocells are used to identify and index to the desired tape cassette. The apparatus allows digital information stored on multiple cassettes to be processed without significant operator intervention.

  20. Excess current experiment on YBCO tape conductor with metal stabilized layer

    NASA Astrophysics Data System (ADS)

    Tasaki, Kenji; Yazawa, Takashi; Ono, Michitaka; Kuriyama, Toru

    2006-06-01

    Excess current experiments were performed using YBCO tape conductors with a metal stabilized layer on the superconducting layer. The purpose of this research is to obtain the stable criteria of energy dissipation when YBCO tape is forced to flow excess current higher than its critical current. This situation should be considered in power applications. In the experiments short-length samples were immersed in liquid nitrogen and several cycles of 50Hz sinusoidal current were supplied to the samples by an induction voltage regulator. The critical current of the samples was about 110 A. With pulse length as long as 60 ms, YBCO tapes were able to be energized up to twelve times as the critical current without electrical or mechanical deformation. Prior to the excess current experiments, temperature dependency of resistance of the sample was measured so that the temperature rise was estimated by the generated resistance. It is found that YBCO tapes with a copper stabilized layer can be transiently heated to over 400K without degradation.

  1. Influence of technology on magnetic tape storage device characteristics

    NASA Technical Reports Server (NTRS)

    Gniewek, John J.; Vogel, Stephen M.

    1994-01-01

    There are available today many data storage devices that serve the diverse application requirements of the consumer, professional entertainment, and computer data processing industries. Storage technologies include semiconductors, several varieties of optical disk, optical tape, magnetic disk, and many varieties of magnetic tape. In some cases, devices are developed with specific characteristics to meet specification requirements. In other cases, an existing storage device is modified and adapted to a different application. For magnetic tape storage devices, examples of the former case are 3480/3490 and QIC device types developed for the high end and low end segments of the data processing industry respectively, VHS, Beta, and 8 mm formats developed for consumer video applications, and D-1, D-2, D-3 formats developed for professional video applications. Examples of modified and adapted devices include 4 mm, 8 mm, 12.7 mm and 19 mm computer data storage devices derived from consumer and professional audio and video applications. With the conversion of the consumer and professional entertainment industries from analog to digital storage and signal processing, there have been increasing references to the 'convergence' of the computer data processing and entertainment industry technologies. There has yet to be seen, however, any evidence of convergence of data storage device types. There are several reasons for this. The diversity of application requirements results in varying degrees of importance for each of the tape storage characteristics.

  2. Laser-assisted patterning of double-sided adhesive tapes for optofluidic chip integration

    NASA Astrophysics Data System (ADS)

    Zamora, Vanessa; Janeczka, Christian; Arndt-Staufenbiel, Norbert; Havlik, George; Queisser, Marco; Schröder, Henning

    2018-02-01

    Portable high-sensitivity biosensors exhibit a growing demand in healthcare, food industry and environmental monitoring sectors. Optical biosensors based on photonic integration platforms are attractive candidates due to their high sensitivity, compactness and multiplexing capabilities. However, they need a low-cost and reliable integration with the microfluidic system. Laser-micropatterned double-sided biocompatible adhesive tapes are promising bonding layers for hybrid integration of an optofluidic biochip. As a part of the EU-PHOCNOSIS project, double-sided adhesive tapes have been proposed to integrate the polymer microfluidic system with the optical integrated waveguide sensor chip. Here the adhesive tape should be patterned in a micrometer scale in order to create an interaction between the sample that flows through the polymer microchannel and the photonic sensing microstructure. Three laser-assisted structuring methods are investigated to transfer microchannel patterns to the adhesive tape. The test structure design consists of a single channel with 400 μm wide, 30 mm length and two circular receivers with 3 mm radius. The best structuring results are found by using the picosecond UV laser where smooth and straight channel cross-sections are obtained. Such patterned tapes are used to bond blank polymer substrates to blank silicon substrates. As a proof of concept, the hybrid integration is tested using colored DI-water. Structuring tests related to the reduction of channel widths are also considered in this work. The use of this technique enables a simple and rapid manufacturing of narrow channels (50-60 μm in width) in adhesive tapes, achieving a cheap and stable integration of the optofluidic biochip.

  3. Adsorption of dispersants on zirconia powder in tape-casting slip compositions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richards, V.L. II

    This paper reports the determination of adsorption isotherms for menhaden fish oil and glycerol trioleate on doped zirconia powder in solvents composed of 70% methyl ethyl ketone (MEK) and 30% ethanol. In order to approach tape-casting zirconia on a sound technical basis, the correspondence of slip viscosities and tape sintered densities to the adsorption isotherms was studied.

  4. Heat reflecting tape for thermoelectric converter

    DOEpatents

    Purdy, David L.

    1977-01-01

    Threads are interlaced with thermoelectric wires to provide a woven cloth in tape form, there being an intermediate layer of heat radiation reflecting material (e.g., aluminum foil) insulated electrically from said wires, which are of opposite thermoelectric polarity and connected as a plurality of thermocouples.

  5. Effects of Taping and Orthoses on Foot Biomechanics in Adults with Flat-Arched Feet.

    PubMed

    Bishop, Christopher; Arnold, John B; May, Thomas

    2016-04-01

    There is a paucity of evidence on the biomechanical effects of foot taping and foot orthoses in realistic conditions. This study aimed to determine the immediate effect and relationships between changes in multisegment foot biomechanics with foot taping and customized foot orthoses in adults with flat-arched feet. Multisegment foot biomechanics were measured in 18 adults with flat-arched feet (age 25.1 ± 2.8 yr; height 1.73 ± .13 m, body mass 70.3 ± 15.7 kg) during walking in four conditions in random order: neutral athletic shoe, neutral shoe with tape (low-Dye method and modified method) and neutral shoe with customized foot orthoses. In-shoe foot biomechanics were compared between conditions using a purpose developed foot model with three-dimensional kinematic analysis and inverse dynamics. Foot orthoses significantly delayed peak eversion compared to the neutral shoe (44% stance vs 39%, P = 0.002). Deformation across the midfoot and medial longitudinal arch was reduced with both the low-Dye taping (2.4°, P < 0.001) and modified taping technique (5.5°, P < 0.001). All interventions increased peak dorsiflexion of the first metatarsophalangeal joint (1.4°-3.2°, P < 0.001-0.023). Biomechanical responses to taping significantly predicted corresponding changes to foot orthoses (R2 = 0.08-0.52, P = 0.006 to <0.001). Foot orthoses more effectively altered timing of hindfoot motion whereas taping was superior in supporting the midfoot and medial longitudinal arch. The biomechanical response to taping was significantly related to the subsequent change observed with the use of foot orthoses.

  6. Magnetic and Electrical Characteristics of Permalloy Thin Tape Bobbin Cores

    NASA Technical Reports Server (NTRS)

    Schwarze, Gene E.; Wieserman, William R.; Niedra, Janis M.

    2005-01-01

    The core loss, that is, the power loss, of a soft ferromagnetic material is a function of the flux density, frequency, temperature, excitation type (voltage or current), excitation waveform (sine, square, etc.) and lamination or tape thickness. In previously published papers we have reported on the specific core loss and dynamic B-H loop results for several polycrystalline, nanocrystalline, and amorphous soft magnetic materials. In this previous research we investigated the effect of flux density, frequency, temperature, and excitation waveform for voltage excitation on the specific core loss and dynamic B-H loop. In this paper, we will report on an experimental study to investigate the effect of tape thicknesses of 1, 1/2, 1/4, and 1/8-mil Permalloy type magnetic materials on the specific core loss. The test cores were fabricated by winding the thin tapes on ceramic bobbin cores. The specific core loss tests were conducted at room temperature and over the frequency range of 10 kHz to 750 kHz using sine wave voltage excitation. The results of this experimental investigation will be presented primarily in graphical form to show the effect of tape thickness, frequency, and magnetic flux density on the specific core loss. Also, the experimental results when applied to power transformer design will be briefly discussed.

  7. Fabrication Of Carbon-Boron Reinforced Dry Polymer Matrix Composite Tape

    NASA Technical Reports Server (NTRS)

    Belvin, Harry L.; Cano, Roberto J.; Treasure, Monte; Shahood, Thomas W.

    1999-01-01

    Future generation aerospace vehicles will require specialized hybrid material forms for component structure fabrication. For this reason, high temperature composite prepregs in both dry and wet forms are being developed at NASA Langley Research Center (LaRC). In an attempt to improve compressive properties of carbon fiber reinforced composites, a hybrid carbon-boron tape was developed and used to fabricate composite laminates which were subsequently cut into flexural and compression specimens and tested. The hybrid material, given the designation HYCARB, was fabricated by modifying a previously developed process for the manufacture of dry polymer matrix composite (PMC) tape at LaRC. In this work, boron fibers were processed with IM7/LaRC(TradeMark)IAX poly(amide acid) solution-coated prepreg to form a dry hybrid tape for Automated Tow Placement (ATP). Boron fibers were encapsulated between two (2) layers of reduced volatile, low fiber areal weight poly(amide acid) solution-coated prepreg. The hybrid prepreg was then fully imidized and consolidated into a dry tape suitable for ATP. The fabrication of a hybrid boron material form for tow placement aids in the reduction of the overall manufacturing cost of boron reinforced composites, while realizing the improved compression strengths. Composite specimens were press-molded from the hybrid material and exhibited excellent mechanical properties.

  8. Comparison of gravimetric and spectroscopic approaches to quantify stratum corneum removed by tape-stripping.

    PubMed

    Mohammed, D; Yang, Q; Guy, R H; Matts, P J; Hadgraft, J; Lane, M E

    2012-09-01

    Skin surface tape-stripping is an extensively used technique to examine the distribution profile, penetration and safety of various active compounds. It is also a widely accepted method to probe skin barrier properties and more specifically, those of the stratum corneum (SC). The amount of SC removed by tape-stripping is generally determined either gravimetrically or by extraction and measurement of SC proteins. A novel infra-red densitometry (IRD) technique has recently been introduced to measure SC protein content. In the present study, IRD was investigated as an alternative method to measure the mass of SC removed by tape-stripping. Tape-stripping experiments were conducted on human volunteers. The weight of the stratum corneum removed was assessed by the gravimetric approach and by IRD. Transepidermal water loss (TEWL) was also measured before and after each tape-strip. A linear correlation coefficient was obtained for the data from the gravimetric and IRD measurements (r(2)=0.65; n=240). IRD is therefore proposed as a rapid, non-destructive alternative to the gravimetric approach to estimate the amount of SC removed by tape-stripping in vivo. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. ERB master archival tape specification no. T 134081 ERB MAT, revision 1

    NASA Technical Reports Server (NTRS)

    1984-01-01

    The Earth radiation budget (ERB)MAT tapes are generated by the ERB MATGEN software using the IBM 3081 computer system operated by the Science and Applications Computer Center at Goddard Space Flight Center. All MAT's are 9-track and MAT data are in ascending time order. The gross tape format for NIMBUS year-1 and year-2 MAT's is different from the format of MAT's starting with year-3. The MATs from the first two years are to contain one day's worth of data while all other MATs are to contain multiple day's worth of data stacked onto the tapes.

  10. Non-contact inline monitoring of thermoplastic CFRP tape quality using air-coupled ultrasound

    NASA Astrophysics Data System (ADS)

    Essig, W.; Fey, P.; Meiler, S.; Kreutzbruck, M.

    2017-02-01

    Beginning with the aerospace industry, fiber reinforced plastics have spread towards many applications such as automotive, civil engineering as well as sports and leisure articles. Their superior strength and stiffness to mass ratio made them the number one material for achieving high performance. Especially continuous fiber reinforced plastics allow for the construction of structures which are custom tailored to their mechanical loads by adjusting the paths of the fibers to the loading direction. The two main constituents of CFRP are carbon fibers and matrix. Two possibilities for matrix material exist: thermosetting and thermoplastic matrix. While thermosetting matrix may yield better properties with respect to thermal loads, thermoplasticity opens a wide range of applications due to weldability, shapeability, and compatibility to e.g. injection molded thermoplastic materials. Thin (0.1 mm) thermoplastic continuous fiber CFRP tapes with a width of 100 mm were examined using air-coupled ultrasound. Transducers were arranged in reflection as well as transmission setup. By slanted incidence of the ultrasound on the tape surface, guided waves were excited in the material in fiber direction and perpendicular to the fiber direction. Artificial defects - fiber cuts, matrix cuts, circular holes, low velocity impacts from tool drop, and sharp bends - were produced. Experiments on a stationary tape showed good detectability of all artificial defects by guided waves. Also the effects of variation in material properties, fiber volume content and fiber matrix adhesion being the most relevant, on guided wave propagation were examined, to allow for quality assessment. Guided wave measurements were supported by destructive analysis. Also an apparatus containing one endless loop of CFRP tape was constructed and built to simulate inline testing of CFRP tapes, as it would be employed in a CFRP tape production environment or at a CFRP tape processing facility. The influences of tape

  11. Properties of pressure-sensitive adhesive tapes with soft adhesives to human skin and their mechanism.

    PubMed

    Tokumura, Fumio; Homma, Takeyasu; Tomiya, Toshiki; Kobayashi, Yuko; Matsuda, Tetsuaki

    2007-05-01

    The use of soft adhesives in the manufacture of pressure-sensitive adhesive tapes has recently increased. The dermal peeling force of adhesive tapes with soft adhesives was studied. Four kinds of adhesive tapes with adhesives of different softness were made, by adding varying amounts of isopropyl myristate as a softener. The tapes were applied on the flexor side of the forearm of six healthy male volunteers. The dermal peeling force, the amount of stripped corneocytes, the level of pain when the tapes were removed and the degree of penetration of adhesives into the sulcus cutis (skin furrows) were evaluated at 1 and 24 h after application of the tapes. Furthermore, a skin model panel (a sulcus cutis and crista cutis model panel) and a crista cutis model panel were constructed from a general stainless-steel panel, and the peeling force of the tapes against the model panels was measured. As the softness of adhesives increased, the peeling force against a general stainless-steel panel with a flat surface decreased, although the peeling force against human skin did not significantly change. The amount of stripped corneocytes on the removed tapes and the level of pain when the tapes were removed decreased with the increase in softness of the adhesives. These results suggest that adhesive tapes with soft adhesives that contain isopropyl myristate as a softener are suitable for the skin. Furthermore, the degree of penetration of adhesive into the sulcus cutis increased as the softness of adhesives increased. Upon evaluation of the peeling force against the model panels, as the softness of adhesives increased, there was a slight decrease in the peeling force against the skin model panel, while there was a remarkable decrease in the peeling force against the crista cutis model panel. These results suggest that the lack of change in the dermal peeling force as the softness of adhesives increased was caused by penetration of soft adhesive into the sulcus cutis, and that the

  12. Digital Linear Tape (DLT) technology and product family overview

    NASA Technical Reports Server (NTRS)

    Lignos, Demetrios

    1994-01-01

    The demand that began a couple of years ago for increased data storage capacity continues. Peripheral Strategies (a Santa Barbara, California, Storage Market Research Firm) projects the amount of data stored on the average enterprise network will grow by 50 percent to 100 percent per year. Furthermore, Peripheral Strategies says that a typical mid-range workstation system containing 30GB to 50GB of storage today will grow at the rate of 50 percent per year. Dan Friedlander, a Boulder, Colorado-based consultant specializing in PC-LAN backup, says, 'The average NetWare LAN is about 8GB, but there are many that have 30GB to 300GB.....' The substantial growth of storage requirements has created various tape technologies that seek to satisfy the needs of today's and, especially, the next generations's systems and applications. There are five leading tape technologies in the market today: QIC (Quarter Inch Cartridge), IBM 3480/90, 8mm, DAT (Digital Audio Tape) and DLT (Digital Linear Tape). Product performance specifications and user needs have combined to classify these technologies into low-end, mid-range, and high-end systems applications. Although the manufacturers may try to position their products differently, product specifications and market requirements have determined that QIC and DAT are primarily low-end systems products while 8mm and DLT are competing for mid-range systems applications and the high-end systems space, where IBM compatibility is not required. The 3480/90 products seem to be used primarily in the IBM market, for interchangeability purposes. There are advantages and disadvantages for each of the tape technologies in the market today. We believe that DLT technology offers a significant number of very important features and specifications that make it extremely attractive for most current as well as emerging new applications, such as Hierarchical Storage Management (HSM). This paper will demonstrate why we think that the DLT technology and family

  13. Ankle taping can reduce external ankle joint moments during drop landings on a tilted surface.

    PubMed

    Sato, Nahoko; Nunome, Hiroyuki; Hopper, Luke S; Ikegami, Yasuo

    2017-09-20

    Ankle taping is commonly used to prevent ankle sprains. However, kinematic assessments investigating the biomechanical effects of ankle taping have provided inconclusive results. This study aimed to determine the effect of ankle taping on the external ankle joint moments during a drop landing on a tilted surface at 25°. Twenty-five participants performed landings on a tilted force platform that caused ankle inversion with and without ankle taping. Landing kinematics were captured using a motion capture system. External ankle inversion moment, the angular impulse due to the medio-lateral and vertical components of ground reaction force (GRF) and their moment arm lengths about the ankle joint were analysed. The foot plantar inclination relative to the ground was assessed. In the taping condition, the foot plantar inclination and ankle inversion angular impulse were reduced significantly compared to that of the control. The only component of the external inversion moment to change significantly in the taped condition was a shortened medio-lateral GRF moment arm length. It can be assumed that the ankle taping altered the foot plantar inclination relative to the ground, thereby shortening the moment arm of medio-lateral GRF that resulted in the reduced ankle inversion angular impulse.

  14. Tension-free transobturator approach for female stress urinary incontinence.

    PubMed

    Cindolo, L; Salzano, L; Rota, G; Bellini, S; D'Afiero, A

    2004-03-01

    UraTape is a new sling for female stress urinary incontinence (SUI) inserted via a transobturator percutaneous approach. We report the safety, feasibility and short-term results of this new surgical procedure. UraTape (Porgès-Mentor) is a non-elastic polypropylene tape, with a silicone coated central part. The sling is placed tension-free under the mid-urethra and extended through the obturator foramen bypassing the posterior face of the ischiopubic ramus. From September 2002 to May 2003, 80 females affected by SUI associated with urethral hypermobility and without severe uro-genital prolapse (with cystocele 1st grade) received UraTape. Mean age was 56 (39-79) years. Sixty-two out of 80 had a positive Q tip test; 16/80 had recurrent incontinence after Burch or colpoplasty according to Kelly; 22/60 had mixed incontinence. Preoperative evaluations included: complete history and physical examination, urinalysis, urodynamic investigations, abdominal and pelvic ultrasound. Quality of life assessment was carried out pre- and postoperatively. Mean operative time was 16 (11-36) minutes. No major intraoperative complications were observed. One bladder neck laceration occurred and was treated intraoperatively. No cystoscopy was performed. Mean hospital postoperative stay time was 1.1 (1-6) days. All patients were examined periodically at 7, 30 and 90 days from intervention (mean follow-up 4 months, 1-8). There was no urethral erosion. One vaginal erosion with inguinal abscess was diagnosed and treated without removing the sling. Two de novo urge incontinence was observed. The objective and subjective cure rates were 92% and 97%; 96% expressed good quality of life (satisfied/very satisfied). This procedure is a safe, effective new technique for the treatment of female SUI. The easy technique, the short learning curve and the very high grade of satisfaction of the patients show that this approach is based upon effective anatomical and physiological criteria. Further follow

  15. The effect of kinesio taping in forward bending of the lumbar spine.

    PubMed

    Lemos, Thiago Vilela; Albino, Anna Carolina Gonçalves; Matheus, Joao Paulo C; Barbosa, Aurélio de Melo

    2014-09-01

    [Purpose] The aim of this study was to evaluate the influence of a lumbar fascia Kinesio Taping(®) technique forward bending range of motion. [Subjects and Methods] This was a longitudinal study with a randomized clinical trial composed of 39 subjects divided into three groups (control, Kinesio Without Tension-KWT, and Kinesio Fascia Correction-KFC). The subjects were assessed by Schober and fingertip-to-floor tests and left the tape in place for 48 hours before being reassessed 24 hours, 48 hours and 30 days after its removal. [Results] In all three experimental groups no significant differences were observed with the Schober test, but it was possible to observe an increase in lumbar flexion after 30 days. With the fingertip-to-floor distance assessment, the KFC and KWT groups showed significantly improved flexibility 24 hours and 48 hours after tape removal. [Conclusion] The Kinesio Taping(®) influenced fascia mobility, allowing for slight improvement of lumbar flexibility.

  16. The Effect of Kinesio Taping in Forward Bending of the Lumbar Spine

    PubMed Central

    Lemos, Thiago Vilela; Albino, Anna Carolina Gonçalves; Matheus, Joao Paulo C.; Barbosa, Aurélio de Melo

    2014-01-01

    [Purpose] The aim of this study was to evaluate the influence of a lumbar fascia Kinesio Taping® technique forward bending range of motion. [Subjects and Methods] This was a longitudinal study with a randomized clinical trial composed of 39 subjects divided into three groups (control, Kinesio Without Tension-KWT, and Kinesio Fascia Correction-KFC). The subjects were assessed by Schober and fingertip-to-floor tests and left the tape in place for 48 hours before being reassessed 24 hours, 48 hours and 30 days after its removal. [Results] In all three experimental groups no significant differences were observed with the Schober test, but it was possible to observe an increase in lumbar flexion after 30 days. With the fingertip-to-floor distance assessment, the KFC and KWT groups showed significantly improved flexibility 24 hours and 48 hours after tape removal. [Conclusion] The Kinesio Taping® influenced fascia mobility, allowing for slight improvement of lumbar flexibility. PMID:25276018

  17. High-Tensile Strength Tape Versus High-Tensile Strength Suture: A Biomechanical Study.

    PubMed

    Gnandt, Ryan J; Smith, Jennifer L; Nguyen-Ta, Kim; McDonald, Lucas; LeClere, Lance E

    2016-02-01

    To determine which suture design, high-tensile strength tape or high-tensile strength suture, performed better at securing human tissue across 4 selected suture techniques commonly used in tendinous repair, by comparing the total load at failure measured during a fixed-rate longitudinal single load to failure using a biomechanical testing machine. Matched sets of tendon specimens with bony attachments were dissected from 15 human cadaveric lower extremities in a manner allowing for direct comparison testing. With the use of selected techniques (simple Mason-Allen in the patellar tendon specimens, whip stitch in the quadriceps tendon specimens, and Krackow stitch in the Achilles tendon specimens), 1 sample of each set was sutured with a 2-mm braided, nonabsorbable, high-tensile strength tape and the other with a No. 2 braided, nonabsorbable, high-tensile strength suture. A total of 120 specimens were tested. Each model was loaded to failure at a fixed longitudinal traction rate of 100 mm/min. The maximum load and failure method were recorded. In the whip stitch and the Krackow-stitch models, the high-tensile strength tape had a significantly greater mean load at failure with a difference of 181 N (P = .001) and 94 N (P = .015) respectively. No significant difference was found in the Mason-Allen and simple stitch models. Pull-through remained the most common method of failure at an overall rate of 56.7% (suture = 55%; tape = 58.3%). In biomechanical testing during a single load to failure, high-tensile strength tape performs more favorably than high-tensile strength suture, with a greater mean load to failure, in both the whip- and Krackow-stitch models. Although suture pull-through remains the most common method of failure, high-tensile strength tape requires a significantly greater load to pull-through in a whip-stitch and Krakow-stitch model. The biomechanical data obtained in the current study indicates that high-tensile strength tape may provide better repair

  18. STS-111 Mission Highlights Resource Tape. Part 1 of 4; Flight Days 1 - 4

    NASA Technical Reports Server (NTRS)

    2002-01-01

    This video, Part 1 of 4, shows the activities of the STS-111 crew (Kenneth Cockrell, Commander; Paul Lockhart, Pilot; Franklin Chang-Diaz, Phillipe Perrin, Mission Specialists) during flight days 1 through 4. Also shown are the incoming Expedition 5 (Valeri Korzun, Commander; Peggy Whitson, NASA ISS Science Officer; Sergei Treschev, Flight Engineer) and outgoing Expedition 4 (Yuri Onufriyenko, Commander; Carl Walz, Daniel Bursch, Flight Engineers) crews of the ISS (International Space Station). The activities from other flight days can be seen on 'STS-111 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002139469), 'STS-111 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139468), and 'STS-111 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002139474). The primary activity of flight day 1 is the launch of Space Shuttle Endeavour. The crew is seen before the launch at a meal and suit-up, and some pre-flight procedures are shown. Perrin holds a sign with a personalized message. The astronauts communicate with Mission Control extensively after launch, and an inside view of the shuttle cabin is shown. The replays of the launch include close-ups of the nozzles at liftoff, and the fall of the solid rocket boosters and the external fuel tank. Flight day 2 shows footage of mainland Asia at night, and daytime views of the eastern United States and Lake Michigan. Flight day three shows the Endeavour orbiter approaching and docking with the ISS. After the night docking, the crews exchange greetings, and a view of the Nile river and Egypt at night is shown. On flight day 4, the MPLM (Multi-Purpose Logistics Module) Leonardo was temporarily transferred from Endeavour's payload bay to the ISS.

  19. The effects of therapeutic taping on gross motor function in children with cerebral palsy.

    PubMed

    Footer, Cheryl Burditt

    2006-01-01

    Therapeutic taping to address dysfunctional sitting control in children with cerebral palsy (CP) was investigated in this study. Eighteen children with quadriplegic CP, Gross Motor Function Classification System for Cerebral Palsy levels IV (n = 9) and V (n = 9) participated in the 12-week program. Subjects were assigned randomly to one of two groups: therapeutic taping + physical therapy or physical therapy only. Therapeutic taping was applied for periods of up to 72 hours over the paraspinal region. The effects were assessed with the Gross Motor Function Measure (GMFM-88) at baseline, six weeks, and 12 weeks. A factorial analysis of variance was used to examine group differences over time. No significant differences were found for the GMFM-88 scores between groups over time. Therapeutic taping does not evoke a positive functional change in the seated postural control of children with quadriplegic cerebral palsy. Subjective observation, however, suggested that one child with athetosis benefited from therapeutic taping over the paraspinal region.

  20. Inefficacy of Kinesio-Taping(®) on early postoperative pain after ACL reconstruction: Prospective comparative study.

    PubMed

    Laborie, M; Klouche, S; Herman, S; Gerometta, A; Lefevre, N; Bohu, Y

    2015-12-01

    Kinesio-Taping(®) (K-Tape) is used in sports traumatology with the aim of reducing pain and improving blood and lymph circulation. The main objective of the present study was to assess the efficacy of K-Tape on early postoperative pain after anterior cruciate ligament (ACL) reconstruction. The study hypothesis was that K-Tape significantly decreases pain. A prospective non-randomized comparative study was conducted in 2013-2014 and included all patients who underwent primary ACL reconstruction by hamstring graft. Analgesia was standardized. Two groups, "K-Tape" and "controls", were formed according to the days on which the study physiotherapist was present. The K-Tape compression/decompression assembly was applied immediately postoperatively and maintained for 3days. Patients filled out online questionnaires. The main assessment criterion was mean postoperative pain (D0-D3) on a 0-to-10 scale. Secondary criteria were analgesia intake on the three WHO levels, awakening during the night of D0 due to pain, signs of postoperative discomfort, and patient satisfaction. Sixty patients (30 per group) were included, 57 of whom could be assessed: 28 K-Tape, 29 controls; 44 male, 13 female; mean age, 30.9±8.9 years. At inclusion, the two groups were comparable. There was no significant difference in mean (D0-D3) knee pain intensity: 3.8±2.2 for K-Tape, and 3.9±2 for controls (P=0.93). Analysis of variance (ANOVA) found no significant intergroup difference in evolution of pain (P=0.34). There were no other significant differences on the other assessment criteria. K-Tape showed no efficacy on early postoperative pain following ACL reconstruction. III; prospective non-randomized comparative study. Copyright © 2015 Elsevier Masson SAS. All rights reserved.