Sample records for tape underlayment rotary-node

  1. Tape underlayment rotary-node (TURN) valves for simple on-chip microfluidic flow control

    PubMed Central

    Markov, Dmitry A.; Manuel, Steven; Shor, Leslie M.; Opalenik, Susan R.; Wikswo, John P.; Samson, Philip C.

    2013-01-01

    We describe a simple and reliable fabrication method for producing multiple, manually activated microfluidic control valves in polydimethylsiloxane (PDMS) devices. These screwdriver-actuated valves reside directly on the microfluidic chip and can provide both simple on/off operation as well as graded control of fluid flow. The fabrication procedure can be easily implemented in any soft lithography lab and requires only two specialized tools – a hot-glue gun and a machined brass mold. To facilitate use in multi-valve fluidic systems, the mold is designed to produce a linear tape that contains a series of plastic rotary nodes with small stainless steel machine screws that form individual valves which can be easily separated for applications when only single valves are required. The tape and its valves are placed on the surface of a partially cured thin PDMS microchannel device while the PDMS is still on the soft-lithographic master, with the master providing alignment marks for the tape. The tape is permanently affixed to the microchannel device by pouring an over-layer of PDMS, to form a full-thickness device with the tape as an enclosed underlayment. The advantages of these Tape Underlayment Rotary-Node (TURN) valves include parallel fabrication of multiple valves, low risk of damaging a microfluidic device during valve installation, high torque, elimination of stripped threads, the capabilities of TURN hydraulic actuators, and facile customization of TURN molds. We have utilized these valves to control microfluidic flow, to control the onset of molecular diffusion, and to manipulate channel connectivity. Practical applications of TURN valves include control of loading and chemokine release in chemotaxis assay devices, flow in microfluidic bioreactors, and channel connectivity in microfluidic devices intended to study competition and predator / prey relationships among microbes. PMID:19859812

  2. Torsional Properties of TiNi Shape Memory Alloy Tape for Rotary Actuator

    NASA Astrophysics Data System (ADS)

    Takeda, K.; Tobushi, H.; Mitsui, K.; Nishimura, Y.; Miyamoto, K.

    2012-12-01

    In order to develop novel shape memory actuators, the torsional deformation of a shape memory alloy (SMA) tape and the actuator models driven by the tape were investigated. The results obtained can be summarized as follows. In the SMA tape subjected to torsion, the martensitic transformation appears along both edges of the tape due to elongation of these elements and grows to the central part. The fatigue life in both the pulsating torsion and alternating torsion is expressed by the unified relationship of the dissipated work in each cycle. Based on an opening and closing door model and a solar-powered active blind model, the two-way rotary driving actuator with a small and simple mechanism can be developed by using torsion of the SMA tape.

  3. A comparison of rotary- and stationary-head tape recorders

    NASA Technical Reports Server (NTRS)

    Watkinson, John R.

    1994-01-01

    Digital recording may take advantage of many types of media, but usually a preferred type of drive or transport emerges for each. In magnetic tape recording, two approaches have emerged in which essentially the same medium is tracked in two radically different ways. This paper compares the characteristics of Rotary- and Stationary-Head transports in an attempt to establish which approach might be considered for a given application. The conclusion is that in many cases there is no obvious choice based on recording physics and that often the choice will be made on the experimental knowledge of the designer.

  4. Effect of Tape Burnishing and Drive Use on Head Wear in Rotary Tape Drives

    NASA Astrophysics Data System (ADS)

    Bhushan, Bharat; Anderson, Reid M.; Koinkar, Vilas N.

    Three types of 12.7-mm wide metal particle tapes were studied. One of the tapes was calendered, whereas the other two tapes were additionally burnished one or two times using a proprietary process. Each type of tape was studied after 100 passes in the BetaCam SP drive and also in the virgin (0 pass) state. It was reported that in the case of the unburnished tape, head wear was high in the first pass and decreased during use. However, head wear for the double burnished tape was low for the first pass and increased during use. Whereas in the single burnished tape, head wear was low in the first pass and remained low. The objective of this study is to understand the mechanisms for loss and growth of head wear by correlating the surface characteristics of the tapes to head wear rate and to determine the changes in the surface characteristics occurring from 0 to 100 passes in the drive. It was found that summit density, mean and rms summit height, and mean and rms summit curvature correlate well to the head wear data. During manufacture and use in the drive, as the summit density, mean and rms summit height, and mean and rms summit curvature decrease, the head wear rate decreases. The mechanism for head wear is the initial ploughing of dense, sharp and high tape asperities into the surface of the head material resulting in a high head wear rate and a high coefficient of friction. Double burnishing during manufacturing removes high asperities, thus making the tape very smooth and possibly results in high adhesion and head wear growth with use. Chemical changes of the tape surface during double burnishing (not part of this study) also may be responsible for head wear growth during use.

  5. Enabling Tussle-Agile Inter-networking Architectures by Underlay Virtualisation

    NASA Astrophysics Data System (ADS)

    Dianati, Mehrdad; Tafazolli, Rahim; Moessner, Klaus

    In this paper, we propose an underlay inter-network virtualisation framework in order to enable tussle-agile flexible networking over the existing inter-network infrastructures. The functionalities that inter-networking elements (transit nodes, access networks, etc.) need to support in order to enable virtualisation are discussed. We propose the base architectures of each the abstract elements to support the required inter-network virtualisation functionalities.

  6. Effects on electron scattering and resist characteristics using assisting underlayers for e-beam direct write lithography

    NASA Astrophysics Data System (ADS)

    Thrun, Xaver; Choi, Kang-Hoon; Hanisch, Norbert; Hohle, Christoph; Steidel, Katja; Guerrero, Douglas; Figueiro, Thiago; Bartha, Johann W.

    2013-03-01

    Resist processing for future technology nodes becomes more and more complex. The resist film thickness is getting thinner and hardmask concepts (trilayer) are needed for reproducible etch transfer into the stack. Additional layers between resist and substrate are influencing the electron scattering in e-beam lithography and may also improve sensitivity and resolution. In this study, bare silicon wafers with different assisting underlayers were processed in a 300 mm CMOS manufacturing environment and were exposed on a 50 keV VISTEC SB3050DW variable-shaped electron beam direct writer at Fraunhofer CNT. The underlayers are organic-inorganic hybrid coatings with different metal additives. The negative-tone resist was evaluated in terms of contrast, sensitivity, resolution and LWR/LER as a function of the stack. The interactions between resist and different assisting underlayers on e-beam direct writing will be investigated. These layers could be used to optimize the trade-off among resolution, LWR and sensitivity in future applications.

  7. Agar Underlay Method for Recovery of Sublethally Heat-Injured Bacteria

    PubMed Central

    Kang, D. H.; Siragusa, G. R.

    1999-01-01

    A method of recovering sublethally heat-injured bacteria was developed. The procedure (termed the agar underlay method) uses a nonselective agar underlaid with a selective medium. In a two-chambered petri dish, the Lutri plate (LP), a nonselective agar is inoculated with a population of sublethally heat-injured bacteria. After a 2-h repair incubation period, selective agar is added to the bottom chamber of the LP and incubated. By diffusing through the nonselective top agar, selective agents from the underlay medium impart selectivity to the system. By the agar underlay method, recovery rates of the heat-injured food-borne pathogens Escherichia coli O157:H7 and Salmonella typhimurium were not different (P > 0.05) from recovery rates determined with nonselective media. Sublethally heat-injured cells (60°C for 1.5 min in buffer or 80°C for 30 s on meat surfaces) grew and produced a typical colony morphology and color reaction when the agar underlay procedure was used with the appropriate respective selective agars. Unlike agar overlay methods for injury repair, the agar underlay procedure allows the typical selective-medium colony morphology to develop and allows colonies to be more easily picked for further characterization. Higher recovery rates of heat-injured fecal enterococci from bovine fecal samples and total coliforms from animal waste lagoons were obtained by the agar underlay method with selective agars than by direct plating on the respective selective media. PMID:10583985

  8. Rotary-scanning optical resolution photoacoustic microscopy

    NASA Astrophysics Data System (ADS)

    Qi, Weizhi; Xi, Lei

    2016-10-01

    Optical resolution photoacoustic microscopy (ORPAM) is currently one of the fastest evolving photoacoustic imaging modalities. It has a comparable spatial resolution to pure optical microscopic techniques such as epifluorescence microscopy, confocal microscopy, and two-photon microscopy, but also owns a deeper penetration depth. In this paper, we report a rotary-scanning (RS)-ORPAM that utilizes a galvanometer scanner integrated with objective to achieve rotary laser scanning. A 15 MHz cylindrically focused ultrasonic transducer is mounted onto a motorized rotation stage to follow optical scanning traces synchronously. To minimize the loss of signal to noise ratio, the acoustic focus is precisely adjusted to reach confocal with optical focus. Black tapes and carbon fibers are firstly imaged to evaluate the performance of the system, and then in vivo imaging of vasculature networks inside the ears and brains of mice is demonstrated using this system.

  9. Availability of underlayer application to EUV process

    NASA Astrophysics Data System (ADS)

    Kosugi, Hitoshi; Fonseca, Carlos; Iwao, Fumiko; Marumoto, Hiroshi; Kim, Hyun-Woo; Cho, Kyoungyong; Park, Cheol-Hong; Park, Chang-Min; Na, Hai-Sub; Koh, Cha-Won; Cho, Hanku

    2011-04-01

    EUV lithography is one of the most promising technologies for the fabrication of beyond 30nm HP generation devices. However, it is well-known that EUV lithography still has significant challenges. A great concern is the change of resist material for EUV resist process. EUV resist material formulations will likely change from conventional-type materials. As a result, substrate dependency needs to be understood. TEL has reported that the simulation combined with experiments is a good way to confirm the substrate dependency. In this work the application of HMDS treatment and SiON introduction, as an underlayer, are studied to cause a footing of resist profile. Then, we applied this simulation technique to Samsung EUV process. We will report the benefit of this simulation work and effect of underlayer application. Regarding the etching process, underlayer film introduction could have significant issues because the film that should be etched off increases. For that purpose, thinner films are better for etching. In general, thinner films may have some coating defects. We will report the coating coverage performance and defectivity of ultra thin film coating.

  10. Seedlayer and underlayer effects on the crystallographic orientation and magnetic recording performance of glass media

    NASA Astrophysics Data System (ADS)

    Zheng, Min; Choe, Geon; Johnson, Kenneth E.

    2002-05-01

    Seedlayer and underlayer effects on crystallographic orientation and recording performance were studied for CoCrPtB media sputtered on glass substrates. For this study, the seedlayers are XAl (X=Ni, Co, Ti, and Ru) and the underlayers are CrY (Y=V, Mo, W, and Ti). It was found that not only different seedlayers, but also different combinations of seedlayer and underlayer, led to different magnetic performance. NiAl and CoAl seedlayers orient the Co c axis to (10.0) and TiAl and RuAl seedlayers produce (11.0) Co orientation. For the NiAl and CoAl seedlayer, CrV and CrW underlayers develop less out-of-plane c-axis orientation and higher coercivity and coercive squareness while CrTi and CrMo underlayers work better for TiAl and RuAl seedlayers, respectively. Media with RuAl seedlayers have better parametric performance than media with NiAl and CoAl seedlayers. The detailed relationship between seedlayer and underlayer types and crystal orientation and recording performance is discussed.

  11. Effect Of Chromium Underlayer On The Properties Of Nano-Crystalline Diamond Films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garratt, Elias; AlFaify, Salem; Yoshitake, T.

    2013-01-11

    This paper investigated the effect of chromium underlayer on the structure, microstructure and composition of the nano-crystalline diamond films. Nano-crystalline diamond thin films were deposited at high temperature in microwave-induced plasma diluted with nitrogen, on silicon substrate with a thin film of chromium as an underlayer. The composition, structure and microstructure of the deposited layers were analyzed using non-Rutherford Backscattering Spectrometry, Raman Spectroscopy, Near-Edge X-Ray Absorption Fine Structure, X-ray Diffraction and Atomic Force Microscopy. Nanoindentation studies showed that the films deposited on chromium underlayer have higher hardness values compared to those deposited on silicon without an underlayer. Diamond and graphiticmore » phases of the films evaluated by x-ray and optical spectroscopic analysis determined consistency between sp2 and sp3 phases of carbon in chromium sample to that of diamond grown on silicon. Diffusion of chromium was observed using ion beam analysis which was correlated with the formation of chromium complexes by x-ray diffraction.« less

  12. Effect of chromium underlayer on the properties of nano-crystalline diamond films

    NASA Astrophysics Data System (ADS)

    Garratt, E.; AlFaify, S.; Yoshitake, T.; Katamune, Y.; Bowden, M.; Nandasiri, M.; Ghantasala, M.; Mancini, D. C.; Thevuthasan, S.; Kayani, A.

    2013-01-01

    This paper investigated the effect of chromium underlayer on the structure, microstructure, and composition of the nano-crystalline diamond films. Nano-crystalline diamond thin films were deposited at high temperature in microwave-induced plasma diluted with nitrogen, on single crystal silicon substrate with a thin film of chromium as an underlayer. Characterization of the film was implemented using non-Rutherford backscattering spectrometry, Raman spectroscopy, near-edge x-ray absorption fine structure, x-ray diffraction, and atomic force microscopy. Nanoindentation studies showed that the films deposited on chromium underlayer have higher hardness values compared to those deposited on silicon without an underlayer. Diamond and graphitic phases of the films evaluated by x-ray and optical spectroscopic analyses determined consistency between the sp2 and sp3 phases of carbon in chromium sample to that of diamond grown on silicon. Diffusion of chromium was observed using ion beam analysis which was correlated with the formation of chromium complexes by x-ray diffraction.

  13. Symbol Error Rate of Underlay Cognitive Relay Systems over Rayleigh Fading Channel

    NASA Astrophysics Data System (ADS)

    Ho van, Khuong; Bao, Vo Nguyen Quoc

    Underlay cognitive systems allow secondary users (SUs) to access the licensed band allocated to primary users (PUs) for better spectrum utilization with the power constraint imposed on SUs such that their operation does not harm the normal communication of PUs. This constraint, which limits the coverage range of SUs, can be offset by relaying techniques that take advantage of shorter range communication for lower path loss. Symbol error rate (SER) analysis of underlay cognitive relay systems over fading channel has not been reported in the literature. This paper fills this gap. The derived SER expressions are validated by simulations and show that underlay cognitive relay systems suffer a high error floor for any modulation level.

  14. Influence of Under-layer Morphology on Structural and Magnetic Properties of Sputtered Co81Pd19 Films

    NASA Astrophysics Data System (ADS)

    Ponchaiya, Pairin; Rattanasakulthong, Watcharee

    2017-09-01

    Sputtered Co81Pd19 films with thickness of about 60 nm were deposited on various under-layers (Co, Ni, Cr and Al) and on glass substrate. Structural, morphological and magnetic properties of Co81Pd19 films were investigated. All of prepared Co81Pd19 film showed CoPd-FCC phase in (111) direction on CoO-FCC (111), NiO-FCC (200), Cr-BCC (200) and (201) and AlO-FCC (200) phases of Co, Ni, Cr and Al under-layer, respectively. AFM images revealed that the film on Cr under-layers and glass substrate exhibited the maximum roughness with the highest grain size and the minimum roughness with the continuous grain size, respectively. Both parallel and perpendicular maximum coercive field were found in the film on glass under-layer and the film on Co-under-layer film showed the highest saturation magnetization from both in-plane and out-of-plane measurements. These results confirmed that the structural and magnetic properties of sputtered Co81Pd19 films were affected by under-layer surface roughness and morphology by the virtue of particle size and distribution on the under-layer film surface.

  15. A Ga2O3 underlayer as an isomorphic template for ultrathin hematite films toward efficient photoelectrochemical water splitting.

    PubMed

    Hisatomi, Takashi; Brillet, Jérémie; Cornuz, Maurin; Le Formal, Florian; Tétreault, Nicolas; Sivula, Kevin; Grätzel, Michael

    2012-01-01

    Hematite photoanodes for photoelectrochemical (PEC) water splitting are often fabricated as extremely-thin films to minimize charge recombination because of the short diffusion lengths of photoexcited carriers. However, poor crystallinity caused by structural interaction with a substrate negates the potential of ultrathin hematite photoanodes. This study demonstrates that ultrathin Ga2O3 underlayers, which were deposited on conducting substrates prior to hematite layers by atomic layer deposition, served as an isomorphic (corundum-type) structural template for ultrathin hematite and improved the photocurrent onset of PEC water splitting by 0.2 V. The benefit from Ga2O3 underlayers was most pronounced when the thickness of the underlayer was approximately 2 nm. Thinner underlayers did not work effectively as a template presumably because of insufficient crystallinity of the underlayer, while thicker ones diminished the PEC performance of hematite because the underlayer prevented electron injection from hematite to a conductive substrate due to the large conduction band offset. The enhancement of PEC performance by a Ga2O3 underlayer was more significant for thinner hematite layers owing to greater margins for improving the crystallinity of ultrathin hematite. It was confirmed that a Ga2O3 underlayer was applicable to a rough conducting substrate loaded with Sb-doped SnO2 nanoparticles, improving the photocurrent by a factor of 1.4. Accordingly, a Ga2O3 underlayer could push forward the development of host-guest-type nanocomposites consisting of highly-rough substrates and extremely-thin hematite absorbers.

  16. Interfacial perpendicular magnetic anisotropy in CoFeB/MgO structure with various underlayers

    NASA Astrophysics Data System (ADS)

    Oh, Young-Wan; Lee, Kyeong-Dong; Jeong, Jong-Ryul; Park, Byong-Guk

    2014-05-01

    Interfacial perpendicular magnetic anisotropy (PMA) in CoFeB/MgO structures was investigated and found to be critically relied on underlayer material and annealing temperature. With Ta or Hf underlayer, clear PMA is observed in as-deposited samples while no PMA was shown in those with Pt or Pd. This may be attributed to smaller saturation magnetization of the films with Ta or Hf underlayer, which makes the PMA of CoFeB/MgO interface dominates over demagnetization field. On the contrary, samples with Pt or Pd demonstrate PMA only after annealing, which might be due to the CoPt (or CoPd) alloy formation that enhances PMA.

  17. Accelerating dewetting on deformable substrates by adding a liquid underlayer.

    PubMed

    Xu, Lin; Reiter, Günter; Shi, Tongfei; An, Lijia

    2010-05-18

    We investigated the dependence of the dewetting velocity of a thin, low-viscosity polystyrene (PS) top film on a poly(methyl methacrylate) (PMMA) double layer consisting of a low-viscosity underlayer of thickness h(L) coated with a high-viscosity middle layer of thickness h(M). The addition of the liquid underlayer generated complex nonmonotonic behavior of the dewetting velocity as a function of increasing h(M). In particular, we observed an acceleration of dewetting for an intermediate range of h(M). This phenomenon has been interpreted by a combination deformation of the middle elastic layer and a concurrent change in the contact angle. On one hand, deformation led to the formation of a trench that dissipated energy during its movement through the liquid underlayer and thus caused a slowing down of dewetting. However, with an increase in the thickness of the elastic middle layer, the size of the trench decreased and its influence on the dewetting velocity also decreased. On the other hand, the deformation of the elastic layer also led to an increase in the contact angle. This increase in the driving capillary forces caused an increase in the dewetting velocity.

  18. Al2 O3 Underlayer Prepared by Atomic Layer Deposition for Efficient Perovskite Solar Cells.

    PubMed

    Zhang, Jinbao; Hultqvist, Adam; Zhang, Tian; Jiang, Liangcong; Ruan, Changqing; Yang, Li; Cheng, Yibing; Edoff, Marika; Johansson, Erik M J

    2017-10-09

    Perovskite solar cells, as an emergent technology for solar energy conversion, have attracted much attention in the solar cell community by demonstrating impressive enhancement in power conversion efficiencies. However, the high temperature and manually processed TiO 2 underlayer prepared by spray pyrolysis significantly limit the large-scale application and device reproducibility of perovskite solar cells. In this study, lowtemperature atomic layer deposition (ALD) is used to prepare a compact Al 2 O 3 underlayer for perovskite solar cells. The thickness of the Al 2 O 3 layer can be controlled well by adjusting the deposition cycles during the ALD process. An optimal Al 2 O 3 layer effectively blocks electron recombination at the perovskite/fluorine-doped tin oxide interface and sufficiently transports electrons through tunneling. Perovskite solar cells fabricated with an Al 2 O 3 layer demonstrated a highest efficiency of 16.2 % for the sample with 50 ALD cycles (ca. 5 nm), which is a significant improvement over underlayer-free PSCs, which have a maximum efficiency of 11.0 %. Detailed characterization confirms that the thickness of the Al 2 O 3 underlayer significantly influences the charge transfer resistance and electron recombination processes in the devices. Furthermore, this work shows the feasibility of using a high band-gap semiconductor such as Al 2 O 3 as the underlayer in perovskite solar cells and opens up pathways to use ALD Al 2 O 3 underlayers for flexible solar cells. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. The double-edged effects of annealing MgO underlayers on the efficient synthesis of single-wall carbon nanotube forests.

    PubMed

    Tsuji, Takashi; Hata, Kenji; Futaba, Don N; Sakurai, Shunsuke

    2017-11-16

    Recently, the millimetre-scale, highly efficient synthesis of single-wall carbon nanotube (SWCNT) forests from Fe catalysts has been reported through the annealing of the magnesia (MgO) underlayer. Here, we report the double-edged effects of underlayer annealing on the efficiency and structure of the SWCNT forest synthesis through a temperature-dependent examination. Our results showed that the efficiency of the SWCNT forests sharply increased with increased underlayer annealing temperatures from 600 °C up to 900 °C due to a temperature-dependent structural modification, characterized by increased grain size and reduced defects, of the MgO underlayer. Beyond this temperature, the SWCNT fraction also decreased as a result of further structural modification of the MgO underlayer. This exemplifies the double-edged effects of annealing. Specifically, for underlayer annealing below 600 °C, the catalyst subsurface diffusion was found to limit the growth efficiency, and for excessively high underlayer annealing temperatures (>900 °C), catalyst coalescence/ripening led to the formation of double-wall carbon nanotubes. As a result, three distinct regions of synthesis were observed: (i) a "low yield" region below a threshold temperature (∼600 °C); (ii) an "increased yield" region from 600 to 900 °C, and (iii) a "saturation" region above 900 °C. The efficient SWCNT forest synthesis could only occur within a specific annealing temperature window as a result of this double-edged effects of underlayer annealing.

  20. Preparation of c-axis perpendicularly oriented ultra-thin L10-FePt films on MgO and VN underlayers

    NASA Astrophysics Data System (ADS)

    Futamoto, Masaaki; Shimizu, Tomoki; Ohtake, Mitsuru

    2018-05-01

    Ultra-thin L10-FePt films of 2 nm average thickness are prepared on (001) oriented MgO and VN underlayers epitaxially grown on base substrate of SrTiO3(001) single crystal. Detailed cross-sectional structures are observed by high-resolution transmission electron microscopy. Continuous L10-FePt(001) thin films with very flat surface are prepared on VN(001) underlayer whereas the films prepared on MgO(001) underlayer consist of isolated L10-FePt(001) crystal islands. Presence of misfit dislocation and lattice bending in L10-FePt material is reducing the effective lattice mismatch with respect to the underlayer to be less than 0.5 %. Formation of very flat and continuous FePt layer on VN underlayer is due to the large surface energy of VN material where de-wetting of FePt material at high temperature annealing process is suppressed under a force balance between the surface and interface energies of FePt and VN materials. An employment of underlayer or substrate material with the lattice constant and the surface energy larger than those of L10-FePt is important for the preparation of very thin FePt epitaxial thin continuous film with the c-axis controlled to be perpendicular to the substrate surface.

  1. Marshburn gives Hadfield a Haircut in Node 1

    NASA Image and Video Library

    2013-04-07

    Expedition 35 flight engineer Tom Marshburn gives commander Chris Hadfield a haircut (using clippers attached to a vacuum hose) in the Unity Node 1. Hadfield (a Canadian Space Agency astronaut) has a temperature sensor taped to his forehead.

  2. Investigation of Ag buffered Ni and Ni-Cr alloys as substrates for the preparation of bismuth superconducting tapes

    NASA Astrophysics Data System (ADS)

    Régnier, P.; Bifulco-Michon, C.; Poissonnet, S.; Martin, H.; Bonnaillie, P.; Giunchi, G.; Legendre, F.

    2002-10-01

    We review and comment on the various requirements that a metallic substrate has to meet to be a good candidate for the fabrication of electrodeposited BSCCO superconducting tapes. We conclude that, in the present state of the art, no metallic substrate is really ideal. Hence we have investigated in detail the use of silver-buffered nickel-based alloys that seem to be a viable alternative to pure silver tape, which is more expensive and less resistant to high temperature. The major difficulty encountered was the occurrence of holes and blisters induced in the silver layers by the oxidation of the nickel underlayer during the heat treatments performed at high temperature in open air, which according to our procedure are required to synthesize high-temperature superconducting tapes. It was found that the liquid phases, transiently present in the process during the synthesis of the precursor phases, infiltrate between the Ag layer and the substrate through these holes and strongly react with the substrate transferring the poisoned element to the superconducting film greatly reducing its superconducting properties. Hence, several routes have been explored to try and suppress hole formation. It was found that pre-oxidizing the substrate at 880 °C for 1 h in open air sufficiently lowers the hole and blister densities to allow us to synthesize good Bi-2212 tapes on pure nickel, but not on Ni80-Cr20 alloys. A much more interesting solution seems to be to pre-anneal the substrate in a hydrogenous atmosphere which permits us to remove blisters and holes.

  3. Improvements of mechanical fatigue reliability of Cu interconnects on flexible substrates through MoTi alloy under-layer

    NASA Astrophysics Data System (ADS)

    Lee, Young-Joo; Shin, Hae-A.-Seul; Nam, Dae-Hyun; Yeon, Han-Wool; Nam, Boae; Woo, Kyoohee; Joo, Young-Chang

    2015-01-01

    The mechanical fatigue of Cu films and lines on flexible substrates was investigated, and an improvement in the structures through the use of a MoTi alloy under-layer was proposed. Fatigue reliability was decreased by 3-fold in lines compared with films in the tensile condition and by 6-fold in the compressive condition. Crack formation was observed to be more detrimental for lines than for films. With a MoTi under-layer, the fatigue limit was increased by 2 times that of a structure without MoTi in the tensile condition and by 15 times in the compressive bending condition. The suppression of delamination through the use of a MoTi under-layer improved the fatigue reliability under compressive bending.

  4. Comparison between clinical and audiological results of tympanoplasty with modified sandwich technique and underlay technique.

    PubMed

    Nemade, Sanjana Vijay; Shinde, Kiran Jaywant; Naik, Chetana Shivadas; Qadri, Haris

    Surgical repair of the tympanic membrane, termed a type one tympanoplasty is a tried and tested treatment modality. Overlay or underlay technique of tympanoplasty is common. Sandwich tympanoplasty is the combined overlay and underlay grafting of tympanic membrane. To describe and evaluate the modified sandwich graft (mediolateral graft) tympanoplasty using temporalis fascia and areolar fascia. To compare the clinical and audiological outcome of modified sandwich tympanoplasty with underlay tympanoplasty. A total of 88 patients of chronic otitis media were studied. 48 patients (Group A) underwent type one tympanoplasty with modified sandwich graft. Temporalis fascia was underlaid and the areolar fascia was overlaid. 48 patients (Group B) underwent type one tympanoplasty with underlay technique. We assessed the healing and hearing results. Successful graft take up was accomplished in 47 patients (97.9%) in Group A and in 40 patients (83.3%) Group B. The average Air-Bone gap closure achieved in Group A was 24.4±1.7dB while in Group B; it was 22.5±3.5dB. Statistically significant difference was found in graft healing rate. Difference in hearing improvement was not statistically significant. Double layered graft with drum-malleus as a 'meat' of sandwich maintains a perfect balance between sufficient stability and adequate acoustic sensitivity. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  5. Tape transport mechanism

    DOEpatents

    Groh, Edward F.; McDowell, William; Modjeski, Norbert S.; Keefe, Donald J.; Groer, Peter

    1979-01-01

    A device is provided for transporting, in a stepwise manner, tape between a feed reel and takeup reel. An indexer moves across the normal path of the tape displacing it while the tape on the takeup reel side of the indexer is braked. After displacement, the takeup reel takes up the displaced tape while the tape on the feed reel side of the indexer is braked, providing stepwise tape transport in precise intervals determined by the amount of displacement caused by the indexer.

  6. Rotary filtration system

    DOEpatents

    Herman, David T [Aiken, SC; Maxwell, David N [Aiken, SC

    2011-04-19

    A rotary filtration apparatus for filtering a feed fluid into permeate is provided. The rotary filtration apparatus includes a container that has a feed fluid inlet. A shaft is at least partially disposed in the container and has a passageway for the transport of permeate. A disk stack made of a plurality of filtration disks is mounted onto the shaft so that rotation of the shaft causes rotation of the filtration disks. The filtration disks may be made of steel components and may be welded together. The shaft may penetrate a filtering section of the container at a single location. The rotary filtration apparatus may also incorporate a bellows seal to prevent leakage along the shaft, and an around the shaft union rotary joint to allow for removal of permeate. Various components of the rotary filtration apparatus may be removed as a single assembly.

  7. Interface control of the magnetic chirality in CoFeB/MgO heterostructures with heavy-metal underlayers.

    PubMed

    Torrejon, Jacob; Kim, Junyeon; Sinha, Jaivardhan; Mitani, Seiji; Hayashi, Masamitsu; Yamanouchi, Michihiko; Ohno, Hideo

    2014-08-18

    Recent advances in the understanding of spin orbital effects in ultrathin magnetic heterostructures have opened new paradigms to control magnetic moments electrically. The Dzyaloshinskii-Moriya interaction (DMI) is said to play a key role in forming a Néel-type domain wall that can be driven by the spin Hall torque. Here we show that the strength and sign of the DMI can be changed by modifying the adjacent heavy-metal underlayer (X) in perpendicularly magnetized X/CoFeB/MgO heterostructures. The sense of rotation of a domain wall spiral is reversed when the underlayer is changed from Hf, Ta to W and the strength of DMI varies as the filling of 5d orbitals, or the electronegativity, of the heavy-metal layer changes. The DMI can even be tuned by adding nitrogen to the underlayer, thus allowing interface engineering of the magnetic texture in ultrathin magnetic heterostructures.

  8. Rotary ATPases

    PubMed Central

    Stewart, Alastair G.; Sobti, Meghna; Harvey, Richard P.; Stock, Daniela

    2013-01-01

    Rotary ATPases are molecular rotary motors involved in biological energy conversion. They either synthesize or hydrolyze the universal biological energy carrier adenosine triphosphate. Recent work has elucidated the general architecture and subunit compositions of all three sub-types of rotary ATPases. Composite models of the intact F-, V- and A-type ATPases have been constructed by fitting high-resolution X-ray structures of individual subunits or sub-complexes into low-resolution electron densities of the intact enzymes derived from electron cryo-microscopy. Electron cryo-tomography has provided new insights into the supra-molecular arrangement of eukaryotic ATP synthases within mitochondria and mass-spectrometry has started to identify specifically bound lipids presumed to be essential for function. Taken together these molecular snapshots show that nano-scale rotary engines have much in common with basic design principles of man made machines from the function of individual “machine elements” to the requirement of the right “fuel” and “oil” for different types of motors. PMID:23369889

  9. Tape tracking and handling for magnetic tape recorders. [aboard spacecraft

    NASA Technical Reports Server (NTRS)

    Paroby, W.; Disilvestre, R.

    1975-01-01

    One of the critical performance and life limiting elements of a spacecraft tape recorder instrumentation system which has received little attention in technical literature is magnetic tape tracking and handling technology. This technology is required to understand how to gently transfer tape from one reel to another with proper alignment and a desirable uniform velocity at the read and write transducer heads. The increased demand for high data rate (i.e., multi-track spacecraft recording instrumentation systems), coupled with performance under extreme environmental conditions, requires a thorough knowledge of the various parameters which establish an optimum designed tape tracking and handling system. Stress analysis techniques are required to evaluate these parameters substantiated with test tape tracking data, to show the effect of each parameter on a tape recorder instrumentation tracking system. The technology is applicable to ground type tape recorders where the detrimental effects of edge guidance can be eliminated.

  10. Five year magnetic tape for unattended satellite tape recorders

    NASA Technical Reports Server (NTRS)

    Benn, G. S. L.; Gutfreund, K.

    1972-01-01

    The development and fabrication of a quantity of long life magnetic tape with properties selected specifically for unattended operation in spacecraft tape recorders was studied. A detailed analytical consideration of various binder systems was undertaken. This included the chemical aspects of the binders, cohesion and adhesion effects, stability and the mechanical and physical properties. The ability to form free films of these polymers and their combination with various oxide loadings and other additives allowed a rapid selection of four polymer candidates for a five year magnetic tape. Samples were evaluated under actual running conditions which included physical, magnetic, and extensive life testing. These sample tapes withstood 50,000 bidirectional tape passes under fairly harsh operating conditions.

  11. Advanced rotary engines

    NASA Technical Reports Server (NTRS)

    Jones, C.

    1983-01-01

    The broad objectives of this paper are the following: (1) to summarize the Curtiss-Wright design, development and field testing background in the area of rotary aircraft engines; (2) to briefly summarize past activity and update development work in the area of stratified charge rotary combustion engines; and (3) to discuss the development of a high-performance direct injected unthrottled stratified charge rotary combustion aircraft engine. Efficiency improvements through turbocharging are also discussed.

  12. Characterizing the Global Impact of P2P Overlays on the AS-Level Underlay

    NASA Astrophysics Data System (ADS)

    Rasti, Amir Hassan; Rejaie, Reza; Willinger, Walter

    This paper examines the problem of characterizing and assessing the global impact of the load imposed by a Peer-to-Peer (P2P) overlay on the AS-level underlay. In particular, we capture Gnutella snapshots for four consecutive years, obtain the corresponding AS-level topology snapshots of the Internet and infer the AS-paths associated with each overlay connection. Assuming a simple model of overlay traffic, we analyze the observed load imposed by these Gnutella snapshots on the AS-level underlay using metrics that characterize the load seen on individual AS-paths and by the transit ASes, illustrate the churn among the top transit ASes during this 4-year period, and describe the propagation of traffic within the AS-level hierarchy.

  13. Tape Placement Head for Applying Thermoplastic Tape to an Object

    NASA Technical Reports Server (NTRS)

    Cope, Ralph D. (Inventor); Funck, Steve B. (Inventor); Gruber, Mark B. (Inventor); Lamontia, Mark A. (Inventor); Johnson, Anthony D. (Inventor)

    2008-01-01

    A tape placement head for applying thermoplastic tape to an object includes a heated feeder which guides the tape/tow to a heated zone. The heated zone has a line compactor having a single row of at least one movable heated member. An area compactor is located in the heated zone downstream from the line compactor. The area compactor includes a plurality of rows of movable feet which are extendable toward the tape/tow different distances with respect to each other to conform to the shape of the object. A shim is located between the heated compactors and the tape/tow. A chilled compactor is in a chilled zone downstream from the heated zone. The chilled zone includes a line chilled compactor and an area chilled compactor. A chilled shim is mounted between the chilled compactor and the tape/tow.

  14. Tape functionality: sonographic tape characteristics and outcome after TVT incontinence surgery.

    PubMed

    Kociszewski, Jacek; Rautenberg, Oliver; Perucchini, Daniele; Eberhard, Jakob; Geissbühler, Verena; Hilgers, Reinhard; Viereck, Volker

    2008-01-01

    To investigate tension-free vaginal tape (TVT) position and shape using ultrasound (US) and correlate the findings to outcome. The results of TVT surgery were investigated in 72 women with urodynamic stress urinary incontinence. The main outcome parameters were US tape position in relation to the urethra and dynamic changes in TVT shape at rest and during straining. Sixty-two patients (86%) were continent, 6 (8%) significantly improved, and the operation failed in four cases (6%). The median tape position was at 66% of the urethral length measured by US. The median tape-urethra-lumen distance was 3.8 mm at rest. Tape placement in the upper or lower quarter of the urethra was associated with a higher failure rate. Tapes positioned less than 3 mm from the urethra significantly increased postoperative complications (P < 0.0001). The tape was flat at rest and curved during straining in 44 (61%) patients; 98% (43/44) of these women were continent after surgery. An unchanged tape shape was associated with a poorer outcome (P = 0.00038). Patients with a flat tape at rest and during straining failed in 25% and patients with a permanent curved shape in 10%. TVT position relative to the patient's urethra seems to play a role in treatment outcome. Outcome was best in patients with dynamic change in tape shape during straining and location of the tape at the junction between the lower and middle urethra and at least 3 mm from the urethral lumen. (c) 2008 Wiley-Liss, Inc.

  15. Herpin effective media resonant underlayers and resonant overlayer designs for ultra-high NA interference lithography.

    PubMed

    Bourke, Levi; Blaikie, Richard J

    2017-12-01

    Dielectric waveguide resonant underlayers are employed in ultra-high NA interference photolithography to effectively double the depth of field. Generally a single high refractive index waveguiding layer is employed. Here multilayer Herpin effective medium methods are explored to develop equivalent multilayer waveguiding layers. Herpin equivalent resonant underlayers are shown to be suitable replacements provided at least one layer within the Herpin trilayer supports propagating fields. In addition, a method of increasing the intensity incident upon the photoresist using resonant overlayers is also developed. This method is shown to greatly enhance the intensity within the photoresist making the use of thicker, safer, non-absorbing, low refractive index matching liquids potentially suitable for large-scale applications.

  16. Electromechanical rotary actuator

    NASA Technical Reports Server (NTRS)

    Smith, S. P.; Mcmahon, W. J.

    1995-01-01

    An electromechanical rotary actuator has been developed as the prime mover for a liquid oxygen modulation valve on the Centaur Vehicle Rocket Engine. The rotary actuator requirements, design, test, and associated problems and their solutions are discussed in this paper.

  17. Electromechanical rotary actuator

    NASA Astrophysics Data System (ADS)

    Smith, S. P.; McMahon, W. J.

    1995-05-01

    An electromechanical rotary actuator has been developed as the prime mover for a liquid oxygen modulation valve on the Centaur Vehicle Rocket Engine. The rotary actuator requirements, design, test, and associated problems and their solutions are discussed in this paper.

  18. Multifuel rotary aircraft engine

    NASA Technical Reports Server (NTRS)

    Jones, C.; Berkowitz, M.

    1980-01-01

    The broad objectives of this paper are the following: (1) to summarize the Curtiss-Wright design, development and field testing background in the area of rotary aircraft engines; (2) to briefly summarize past activity and update development work in the area of stratified charge rotary combustion engines; and (3) to discuss the development of a high-performance direct injected unthrottled stratified charge rotary combustion aircraft engine. Efficiency improvements through turbocharging are also discussed.

  19. [Laryngeal Tube Position Shift after Chest Compression: Comparison of Fixation Methods Using Durapore Tape, Multipore Tape, or a Neck Tape].

    PubMed

    Seno, Hisayo; Komasawa, Nobuyasu; Fujiwara, Shunsuke; Miyazaki, Shinichiro; Tatsumi, Shinichi; Minami, Toshiaki

    2015-05-01

    The laryngeal tube (LT ; Smiths Medical, Minnesota, U. S. A) is an inflatable supraglottic device for emergency airway management such as during chest compression, the instability after insertion remains a problem. We investigated the effectiveness of three fixation methods of LT using a manikin and automated chest compressor. After 10-minute chest compression, LT without fixation was shifted by 0.4 ± 0.1 cm, which was greater than with Durapore tape (0.2 ± 0.1 cm), Multipore tape (0.2 ± 0.1 cm), or a neck tape (0.1 ± 0.1 cm). The shift of the position was smaller with neck tape fixation compared to Durapore or Multipore tape fixation. A fixation neck tape may be useful in stabilizing the inserted position of LT during cardiopulmonary resuscitation.

  20. Tape reading fixture

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Commercially available roller type desk pad provides an efficient and orderly manner of handling rolled paper tapes for proofreading. The fixture, which is modified to accept Flex-O-Writer or similar tapes and roll them in either direction, reduces the chance of damaging or soiling the tapes through repeated handling.

  1. Thermoplastic tape compaction device

    DOEpatents

    Campbell, V.W.

    1994-12-27

    A device is disclosed for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite. 5 figures.

  2. Thermoplastic tape compaction device

    DOEpatents

    Campbell, Vincent W.

    1994-01-01

    A device for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite.

  3. Thermoplastic tape compaction device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, V.W.

    1994-12-27

    A device is disclosed for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin bandmore » of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite. 5 figures.« less

  4. PHOTOELECTRIC CONTROL FOR TAPE POSITIONING

    DOEpatents

    Woody, J.W. Jr.

    1961-07-25

    A control system is described for producing control impulses which may be used to start, stop, and position a magnetic tape with respect to a transducer, and to locate discrete areas on the tape. Means are provided for positive identification of data blocks, exact positioning of the tape under the magnetic head, drive in either direction, accurate skip-over of imperfect regions of the tape, stopping the tape if equipment malfunction results in a failure to detect the block-identifying signals, and starting and stopping those parts of the tape between of the tape drive clutches.

  5. The Carbon Monoxide Tape Recorder

    NASA Technical Reports Server (NTRS)

    Schoeberl, M. R.; Duncan, B. N.; Douglass, A. R.; Waters, J.; Livesey, N.; Read, W.; Filipiak, M.

    2006-01-01

    Using Aura MLS data we have identified the stratospheric tape recorder in carbon monoxide (CO). Unlike the water vapor tape recorder, which is controlled by upper troposphere processes, the CO tape recorder is linked to seasonal biomass burning. Since CO has a lifetime of only a few months, the CO tape recorder barely extends above 20 km. The tape head for CO appears to be close to 360K near the same location as the water vapor tape head [Read et al, 20041. Both tape heads are below the equatorial cold point tropopause but above the base of the tropical tropopause layer. The tape recorder signal becomes more distinct from 360K to 380K suggesting that convective detrainment of plays a decreasingly important role with altitude. The Global Modeling Initiative chemical transport model forced by the climatology of biomass burning reproduces the CO tape recorder.

  6. Rotary Transformer

    NASA Technical Reports Server (NTRS)

    McLyman, Colonel Wm. T.

    1996-01-01

    None given. From first Par: Many spacecraft (S/C) and surface rovers require the transfer of signals and power across rotating interfaces. Science instruments, antennas and solar arrays are elements needing rotary power transfer for certain (S/C) configurations. Delivery of signal and power has mainly been done by using the simplest means, the slip ring approach. This approach, although simple, leaves debris generating noise over a period of time...The rotary transformer is a good alternative to slip rings for signal and power transfer.

  7. Performance of current-in-plane pseudo-spin-valve devices on CMOS silicon-on-insulator underlayers

    NASA Astrophysics Data System (ADS)

    Katti, R. R.; Zou, D.; Reed, D.; Schipper, D.; Hynes, O.; Shaw, G.; Kaakani, H.

    2003-05-01

    Prior work has shown that current-in-plane (CIP) giant magnetoresistive (GMR) pseudo-spin-valve (PSV) devices grown on bulk Si wafers and bulk complementary metal-oxide semiconductor (CMOS) underlayers exhibit write and read characteristics that are suitable for application as nonvolatile memory devices. In this work, CIP GMR PSV devices fabricated on silicon-on-insulator CMOS underlayers are shown to support write and read performance. Reading and writing fields for selected devices are shown to be approximately 25%-50% that of unselected devices, which provides a margin for reading and writing specific bits in a memory without overwriting bits and without disturbing other bits. The switching characteristics of experimental devices were compared to and found to be similar with Landau-Lifschitz-Gilbert micromagnetic modeling results, which allowed inferring regions of reversible and irreversible rotations in magnetic reversal processes.

  8. Superconducting properties of multilayered Ag/Bi(Pb)-2223 tapes prepared using pretextured monolayered tapes

    NASA Astrophysics Data System (ADS)

    Syamaprasad, U.; Sarma, M. S.; Guruswamy, P.; Pillai, S. G. K.; Warrier, K. G. K.; Damodaran, A. D.

    1997-02-01

    Multilayered Ag/Bi(Pb)-2223 tapes with high critical current densities 0953-2048/10/2/005/img1 have been fabricated using partially heat treated, textured monolayered tapes. Cut sections of the monolayered tapes have been stacked one over the other and folded together using high-purity silver foil and further rolled and heat treated to obtain multilayered tapes of different thickness with an HTS layer thickness varying from 9 to 0953-2048/10/2/005/img2. A comparison of the superconducting properties of the multilayered tapes with those of monolayered tapes prepared under identical heat treatment conditions shows that the 0953-2048/10/2/005/img3 ratio at 77 K is as high as 0.57. The ratio is found to decrease with a decrease in the HTS core thickness of the multilayered tapes. XRD studies of `banana peeled' samples show that the monolayered tapes at the folding stage acquire a good degree of texturing. The relatively high value of the 0953-2048/10/2/005/img3 ratio obtained in the present case compared with those reported by the existing techniques is attributed to the use of pretextured monolayered tapes.

  9. Magnetic tape user guide

    NASA Technical Reports Server (NTRS)

    Evans, A. B.; Lee, L. L.

    1985-01-01

    This User Guide provides a general introduction to the structure, use, and handling of magnetic tapes at Langley Research Center (LaRC). The topics covered are tape terminology, physical characteristics, error prevention and detection, and creating, using, and maintaining tapes. Supplementary documentation is referenced where it might be helpful. The documentation is included for the tape utility programs, BLOCK, UNBLOCK, and TAPEDMP, which are available at the Central Scientific Computing Complex at LaRC.

  10. Smart hybrid rotary damper

    NASA Astrophysics Data System (ADS)

    Yang, C. S. Walter; DesRoches, Reginald

    2014-03-01

    This paper develops a smart hybrid rotary damper using a re-centering smart shape memory alloy (SMA) material as well as conventional energy-dissipating metallic plates that are easy to be replaced. The ends of the SMA and steel plates are inserted in the hinge. When the damper rotates, all the plates bend, providing energy dissipating and recentering characteristics. Such smart hybrid rotary dampers can be installed in structures to mitigate structural responses and to re-center automatically. The damaged energy-dissipating plates can be easily replaced promptly after an external excitation, reducing repair time and costs. An OpenSEES model of a smart hybrid rotary was established and calibrated to reproduce the realistic behavior measured from a full-scale experimental test. Furthermore, the seismic performance of a 3-story moment resisting model building with smart hybrid rotary dampers designed for downtown Los Angeles was also evaluated in the OpenSEES structural analysis software. Such a smart moment resisting frame exhibits perfect residual roof displacement, 0.006", extremely smaller than 18.04" for the conventional moment resisting frame subjected to a 2500 year return period ground motion for the downtown LA area (an amplified factor of 1.15 on Kobe earthquake). The smart hybrid rotary dampers are also applied into an eccentric braced steel frame, which combines a moment frame system and a bracing system. The results illustrate that adding smart hybrid rotaries in this braced system not only completely restores the building after an external excitation, but also significantly reduces peak interstory drifts.

  11. Tape/head interface study

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Existing high energy tapes, high track density heads, and transport guidance techniques were evaluated and characterized to enable these technologies to be employed in future spacecraft recorders with high confidence. The results of these study efforts demonstrated tracking accuracy tape and head density that will support spacecraft recorders with data rates of a minimum of 150 Mbps and storage capacities ranging from 10 to the 10th to 10 to the 11th bits. Seven high energy tapes of either .25 in width, 1.00 in width, or both, were tested. All tapes were tested at the same speed (30 ips) and the same packing density (33 KBI). The performance of all 1 in tapes was considered superior.

  12. Sequenced drive for rotary valves

    DOEpatents

    Mittell, Larry C.

    1981-01-01

    A sequenced drive for rotary valves which provides the benefits of applying rotary and linear motions to the movable sealing element of the valve. The sequenced drive provides a close approximation of linear motion while engaging or disengaging the movable element with the seat minimizing wear and damage due to scrubbing action. The rotary motion of the drive swings the movable element out of the flowpath thus eliminating obstruction to flow through the valve.

  13. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  14. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  15. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  16. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  17. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  18. Interface influence on the properties of Co90Fe10 films on soft magnetic underlayers - Magnetostrictive and Mössbauer spectrometry studies

    NASA Astrophysics Data System (ADS)

    Szumiata, Tadeusz; Gzik-Szumiata, Małgorzata; Brzózka, Katarzyna; Górka, Bogumił; Gawroński, Michał; Caruana Finkel, Anastasia; Reeves-McLaren, Nik; Morley, Nicola A.

    2016-03-01

    The main aim of the work was to show the correlation between magnetostrictive properties and microstructure of 25 nm thick Co90Fe10 films deposited on soft magnetic underlayers. A special attention was paid to the role of the interface region. In the case of Co90Fe10 on 25 nm and 35 nm thick METGLAS underlayers one can resolve in conversion electron Mössbauer spectra two hyperfine field distributions (high-field and medium-field ones) corresponding to both constituents of bilayers. Analogical distributions describe the spectra of Co90Fe10 on 25 nm and 35 nm thick Ni81Fe19 underlayers, however an additional low-field, smeared component has been observed. It has been attributed to the interface layer (of partially disordered structure) between magnetostrictive layer and soft magnetic layer. Such interpretation is backed up by the obtained strong correlation between mean hyperfine field value and magnetostriction constant of the films. The investigated bilayers are good candidates for MRAM devices.

  19. Magnetic Tape Recording for the Eighties

    NASA Technical Reports Server (NTRS)

    Kalil, Ford (Editor)

    1982-01-01

    The practical and theoretical aspects of state-of-the-art magnetic tape recording technology are reviewed. Topics covered include the following: (1) analog and digital magnetic tape recording, (2) tape and head wear, (3) wear testing, (4) magnetic tape certification, (5) care, handling, and management of magnetic tape, (6) cleaning, packing, and winding of magnetic tape, (7) tape reels, bands, and packaging, (8) coding techniques for high-density digital recording, and (9) tradeoffs of coding techniques.

  20. Accuracy testing of steel and electric groundwater-level measuring tapes: Test method and in-service tape accuracy

    USGS Publications Warehouse

    Fulford, Janice M.; Clayton, Christopher S.

    2015-10-09

    The calibration device and proposed method were used to calibrate a sample of in-service USGS steel and electric groundwater tapes. The sample of in-service groundwater steel tapes were in relatively good condition. All steel tapes, except one, were accurate to ±0.01 ft per 100 ft over their entire length. One steel tape, which had obvious damage in the first hundred feet, was marginally outside the accuracy of ±0.01 ft per 100 ft by 0.001 ft. The sample of in-service groundwater-level electric tapes were in a range of conditions—from like new, with cosmetic damage, to nonfunctional. The in-service electric tapes did not meet the USGS accuracy recommendation of ±0.01 ft. In-service electric tapes, except for the nonfunctional tape, were accurate to about ±0.03 ft per 100 ft. A comparison of new with in-service electric tapes found that steel-core electric tapes maintained their length and accuracy better than electric tapes without a steel core. The in-service steel tapes could be used as is and achieve USGS accuracy recommendations for groundwater-level measurements. The in-service electric tapes require tape corrections to achieve USGS accuracy recommendations for groundwater-level measurement.

  1. Kinesio taping or sham taping in knee osteoarthritis? A randomized, double-blind, sham-controlled trial.

    PubMed

    Kocyigit, Figen; Turkmen, Mehmet Besir; Acar, Merve; Guldane, Nezahat; Kose, Tugce; Kuyucu, Ersin; Erdil, Mehmet

    2015-11-01

    To compare effects of kinesio taping with sham taping at the end of 3 consecutive taping periods in knee osteoarthritis. 41 patients diagnosed with knee osteoarthritis according to American College of Rheumatology were randomized to receive either KT or sham taping. Baseline evaluations included a visual analog scale (VAS) for activity and nocturnal pain, Lequesne index for functional assessment and Nottingham Health Profile (NHP) for the quality of life. Taping was applied every four days, three times, and all of the assessments were repeated at the end of the treatment period. In both groups VAS for activity pain, VAS for nocturnal pain, Lequesne index score, NHP score decreased significantly. NHP energy scores were different significantly between the groups in favor of sham taping at the end of the 12-day period. Our findings indicate inconclusive evidence of a beneficial effect of kinesio taping over sham taping in knee osteoarthritis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Main image file tape description

    USGS Publications Warehouse

    Warriner, Howard W.

    1980-01-01

    This Main Image File Tape document defines the data content and file structure of the Main Image File Tape (MIFT) produced by the EROS Data Center (EDC). This document also defines an INQUIRY tape, which is just a subset of the MIFT. The format of the INQUIRY tape is identical to the MIFT except for two records; therefore, with the exception of these two records (described elsewhere in this document), every remark made about the MIFT is true for the INQUIRY tape.

  3. Rotary balances: A selected, annotated bibliography

    NASA Technical Reports Server (NTRS)

    Tuttle, Marie H.; Kilgore, Robert A.; Sych, Karen L.

    1989-01-01

    This bibliography on rotary balances contains 102 entries. It is part of NASA's support of the AGARD Fluid Dynamics Panel Working Group 11 on Rotary Balances. This bibliography includes works that might be useful to anyone interested in building or using rotor balances. Emphasis is on the rotary balance rigs and testing techniques rather than the aerodynamic data. Also included are some publications of historical interest which relate to key events in the development and use of rotary balances. The arrangement is chronological by date of publication in the case of reports and by presentation in the case of papers.

  4. The influence of Kinesiology Taping on the reduction of lymphoedema among women after mastectomy – preliminary study

    PubMed Central

    Karczmarek-Borowska, Bożenna; Tymczak, Monika; Hałas, Ireneusz; Banaś, Joanna

    2014-01-01

    Introduction Kinesiology Taping is a method that assists healing processes and improves the physical efficiency. The aim of the study The aim of the study was to assess the influence of Kinesiology Taping on the lymphoedema reduction among women after mastectomy. Material and methods The subject of the research included 44 women underwent single mastectomy along with the removal of lymph nodes. The examination was carried out from the 4th of January to the 4th of February, 2013. The traditional taping method was implemented among 22 women, whereas the own taping method was used among the other 22 women. The therapy took 21 days, during which the tapes were applied three times every 7 days. The measurements were made before every application and at the end of the therapy. In the study, a questionnaire was used and it included questions concerning basic demographic, epidemiological data as well as the evaluation of the therapy effectiveness. The linear measurements of the upper limbs, the measurements of the range of joints’ motion in the upper limb were taken as well as grip strength was made. Results The reduction of the volume of lymphoedema of 55% was reported in the study group, whereas the oedema reduced by 27% in the clinical control one. Conclusions In the reduction of lymphoedema, the greater effectiveness of the own taping method in comparison to the traditional one was reported. Kinesiology Taping exerted an influence on the improvement of the upper limb's joints movability and the grip strength. PMID:24966797

  5. Use of binaural beat tapes for treatment of anxiety: a pilot study of tape preference and outcomes.

    PubMed

    Le Scouarnec, R P; Poirier, R M; Owens, J E; Gauthier, J; Taylor, A G; Foresman, P A

    2001-01-01

    Recent studies and anecdotal reports suggest that binaural auditory beats can affect mood, performance on vigilance tasks, and anxiety. To determine whether mildly anxious people would report decreased anxiety after listening daily for 1 month to tapes imbedded with tones that create binaural beats, and whether they would show a definite tape preference among 3 tapes. A 1-group pre-posttest pilot study. Patients' homes. A volunteer sample of 15 mildly anxious patients seen in the Clinique Psyché, Montreal, Quebec. Participants were asked to listen at least 5 times weekly for 4 weeks to 1 or more of 3 music tapes containing tones that produce binaural beats in the electroencephalogram delta/theta frequency range. Participants also were asked to record tape usage, tape preference, and anxiety ratings in a journal before and after listening to the tape or tapes. Anxiety ratings before and after tape listening, pre- and post-study State-Trait Anxiety Inventory scores, and tape preferences documented in daily journals. Listening to the binaural beat tapes resulted in a significant reduction in the anxiety score reported daily in patients' diaries. The number of times participants listened to the tapes in 4 weeks ranged from 10 to 17 (an average of 1.4 to 2.4 times per week) for approximately 30 minutes per session. End-of-study tape preferences indicated that slightly more participants preferred tape B, with its pronounced and extended patterns of binaural beats, over tapes A and C. Changes in pre- and posttest listening State-Trait Anxiety Inventory scores trended toward a reduction of anxiety, but these differences were not statistically significant. Listening to binaural beat tapes in the delta/theta electroencephalogram range may be beneficial in reducing mild anxiety. Future studies should account for music preference among participants and include age as a factor in outcomes, incentives to foster tape listening, and a physiologic measure of anxiety reduction. A

  6. Rotary shaft sealing assembly

    DOEpatents

    Dietle, Lannie L; Schroeder, John E; Kalsi, Manmohan S; Alvarez, Patricio D

    2013-08-13

    A rotary shaft sealing assembly in which a first fluid is partitioned from a second fluid in a housing assembly having a rotary shaft located at least partially within. In one embodiment a lip seal is lubricated and flushed with a pressure-generating seal ring preferably having an angled diverting feature. The pressure-generating seal ring and a hydrodynamic seal may be used to define a lubricant-filled region with each of the seals having hydrodynamic inlets facing the lubricant-filled region. Another aspect of the sealing assembly is having a seal to contain pressurized lubricant while withstanding high rotary speeds. Another rotary shaft sealing assembly embodiment includes a lubricant supply providing a lubricant at an elevated pressure to a region between a lip seal and a hydrodynamic seal with a flow control regulating the flow of lubricant past the lip seal. The hydrodynamic seal may include an energizer element having a modulus of elasticity greater than the modulus of elasticity of a sealing lip of the hydrodynamic seal.

  7. Rotary shaft sealing assembly

    DOEpatents

    Dietle, Lannie L.; Schroeder, John E.; Kalsi, Manmohan S.; Alvarez, Patricio D.

    2010-09-21

    A rotary shaft sealing assembly in which a first fluid is partitioned from a second fluid in a housing assembly having a rotary shaft located at least partially within. In one embodiment a lip seal is lubricated and flushed with a pressure-generating seal ring preferably having an angled diverting feature. The pressure-generating seal ring and a hydrodynamic seal may be used to define a lubricant-filled region with each of the seals having hydrodynamic inlets facing the lubricant-filled region. Another aspect of the sealing assembly is having a seal to contain pressurized lubricant while withstanding high rotary speeds. Another rotary shaft sealing assembly embodiment includes a lubricant supply providing a lubricant at an elevated pressure to a region between a lip seal and a hydrodynamic seal with a flow control regulating the flow of lubricant past the lip seal. The hydrodynamic seal may include an energizer element having a modulus of elasticity greater than the modulus of elasticity of a sealing lip of the hydrodynamic seal.

  8. Restoration of Apollo Data by the NSSDC and the PDS Lunar Data Node

    NASA Technical Reports Server (NTRS)

    Williams, David R.; Hills, H. Kent; Lowman, Paul D.; Taylor, Patrick T.; Guinness, Edward A.

    2011-01-01

    The Lunar Data Node (LDN), under the auspices of the Geosciences Node of the Planetary Data System (PDS), is restoring Apollo data archived at the National Space Science Data Center. The Apollo data were arch ived on older media (7 -track tapes. microfilm, microfiche) and in ob solete digital formats, which limits use of the data. The LDN is maki ng these data accessible by restoring them to standard formats and archiving them through PDS. The restoration involves reading the older m edia, collecting supporting data (metadata), deciphering and understa nding the data, and organizing into a data set. The data undergo a pe er review before archive at PDS. We will give an update on last year' s work. We have scanned notebooks from Otto Berg, P.1. for the Lunar Ejecta and Meteorites Experiment. These notebooks contain information on the data and calibration coefficients which we hope to be able to use to restore the raw data into a usable archive. We have scanned Ap ollo 14 and 15 Dust Detector data from microfilm and are in the proce ss of archiving thc scans with PDS. We are also restoring raw dust de tector data from magnetic tape supplied by Yosio Nakamura (UT Austin) . Seiichi Nagihara (Texas Tech Univ.) and others in cooperation with NSSDC are recovering ARCSAV tapes (tapes containing raw data streams from all the ALSEP instruments). We will be preparing these data for archive with PDS. We are also in the process of recovering and archivi ng data not previously archived, from the Apollo 16 Gamma Ray Spectro meter and the Apollo 17 Infrared Spectrometer.

  9. Rotary Series Elastic Actuator

    NASA Technical Reports Server (NTRS)

    Ihrke, Chris A. (Inventor); Mehling, Joshua S. (Inventor); Parsons, Adam H. (Inventor); Griffith, Bryan Kristian (Inventor); Radford, Nicolaus A. (Inventor); Permenter, Frank Noble (Inventor); Davis, Donald R. (Inventor); Ambrose, Robert O. (Inventor); Junkin, Lucien Q. (Inventor)

    2013-01-01

    A rotary actuator assembly is provided for actuation of an upper arm assembly for a dexterous humanoid robot. The upper arm assembly for the humanoid robot includes a plurality of arm support frames each defining an axis. A plurality of rotary actuator assemblies are each mounted to one of the plurality of arm support frames about the respective axes. Each rotary actuator assembly includes a motor mounted about the respective axis, a gear drive rotatably connected to the motor, and a torsion spring. The torsion spring has a spring input that is rotatably connected to an output of the gear drive and a spring output that is connected to an output for the joint.

  10. Rotary series elastic actuator

    NASA Technical Reports Server (NTRS)

    Ihrke, Chris A. (Inventor); Mehling, Joshua S. (Inventor); Parsons, Adam H. (Inventor); Griffith, Bryan Kristian (Inventor); Radford, Nicolaus A. (Inventor); Permenter, Frank Noble (Inventor); Davis, Donald R. (Inventor); Ambrose, Robert O. (Inventor); Junkin, Lucien Q. (Inventor)

    2012-01-01

    A rotary actuator assembly is provided for actuation of an upper arm assembly for a dexterous humanoid robot. The upper arm assembly for the humanoid robot includes a plurality of arm support frames each defining an axis. A plurality of rotary actuator assemblies are each mounted to one of the plurality of arm support frames about the respective axes. Each rotary actuator assembly includes a motor mounted about the respective axis, a gear drive rotatably connected to the motor, and a torsion spring. The torsion spring has a spring input that is rotatably connected to an output of the gear drive and a spring output that is connected to an output for the joint.

  11. Industrial Tape

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Scotch Brand Tape 364 was developed for NASA by 3M Company to protect electrical instrumentation coils and fluid lines from rocket launch blast conditions. It is an aluminized glass cloth tape which can withstand very high temperatures, is easily applied to compound surfaces, has excellent solar energy reflectance, and does not present an electrostatic hazard. It has potential automotive, transportation, and building construction applications.

  12. Tape-Drop Transient Model for In-Situ Automated Tape Placement of Thermoplastic Composites

    NASA Technical Reports Server (NTRS)

    Costen, Robert C.; Marchello, Joseph M.

    1998-01-01

    Composite parts of nonuniform thickness can be fabricated by in-situ automated tape placement (ATP) if the tape can be started and stopped at interior points of the part instead of always at its edges. This technique is termed start/stop-on-the-part, or, alternatively, tape-add/tape-drop. The resulting thermal transients need to be managed in order to achieve net shape and maintain uniform interlaminar weld strength and crystallinity. Starting-on-the-part has been treated previously. This paper continues the study with a thermal analysis of stopping-on-the-part. The thermal source is switched off when the trailing end of the tape enters the nip region of the laydown/consolidation head. The thermal transient is determined by a Fourier-Laplace transform solution of the two-dimensional, time-dependent thermal transport equation. This solution requires that the Peclet number Pe (the dimensionless ratio of inertial to diffusive heat transport) be independent of time and much greater than 1. Plotted isotherms show that the trailing tape-end cools more rapidly than the downstream portions of tape. This cooling can weaken the bond near the tape end; however the length of the affected region is found to be less than 2 mm. To achieve net shape, the consolidation head must continue to move after cut-off until the temperature on the weld interface decreases to the glass transition temperature. The time and elapsed distance for this condition to occur are computed for the Langley ATP robot applying PEEK/carbon fiber composite tape and for two upgrades in robot performance. The elapsed distance after cut-off ranges from about 1 mm for the present robot to about 1 cm for the second upgrade.

  13. Hygroscopic properties of magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Cuddihy, E. F.

    1976-01-01

    Relative humidity has been recognized as an important environmental factor in many head-tape interface phenomena such as headwear, friction, staining, and tape shed. Accordingly, the relative humidity is usually specified in many applications of tape use, especially when tape recorders are enclosed in hermetically sealed cases. Normally, the relative humidity is believed regulated by humidification of the fill gas to the specification relative humidity. This study demonstrates that the internal relative humidity in a sealed case is completely controlled by the time-dpendence of the hygroscopic properties of the pack of magnetic recording tape. Differences are found in the hygroscopic properties of the same brand of tape, which apparently result from aging, and which may have an effect on the long-term humidity-regulating behavior in a sealed case, and on the occurrence of head-tape interface phenomena from the long-term use of the tape. Results are presented on the basic hygroscopic properties of magnetic tape, its humidity-regulating behavior in a sealed case, and a theoretical commentary on the relative humidity dependence of head-wear by tape, is included.

  14. ICI optical data storage tape

    NASA Technical Reports Server (NTRS)

    Mclean, Robert A.; Duffy, Joseph F.

    1991-01-01

    Optical data storage tape is now a commercial reality. The world's first successful development of a digital optical tape system is complete. This is based on the Creo 1003 optical tape recorder with ICI 1012 write-once optical tape media. Several other optical tape drive development programs are underway, including one using the IBM 3480 style cartridge at LaserTape Systems. In order to understand the significance and potential of this step change in recording technology, it is useful to review the historical progress of optical storage. This has been slow to encroach on magnetic storage, and has not made any serious dent on the world's mountains of paper and microfilm. Some of the reasons for this are the long time needed for applications developers, systems integrators, and end users to take advantage of the potential storage capacity; access time and data transfer rate have traditionally been too slow for high-performance applications; and optical disk media has been expensive compared with magnetic tape. ICI's strategy in response to these concerns was to concentrate its efforts on flexible optical media; in particular optical tape. The manufacturing achievements, media characteristics, and media lifetime of optical media are discussed.

  15. Repulsive force actuated rotary micromirror

    NASA Astrophysics Data System (ADS)

    He, Siyuan; Ben Mrad, Ridha

    2004-09-01

    In this paper, a novel repulsive force based rotary micromirror is proposed. A repulsive force is produced in the rotary micromirror and the mirror plate is pushed up and away from the substrate. Therefore the rotation angle of the micromirror is not limited to the space underneath the mirror plate and thus the "pull-in" effect is completely circumvented. The novel rotary micromirror can achieve a large rotation angle with a large mirror plate. In addition the novel micromirror has a very simple structure and can be fabricated by standard surface micromachining technology. Numerical simulation is used to verify the working principle of the novel micromirror. A prototype of the novel rotary micromirror is fabricated by a commercially available surface microfabrication process called MUMPs. The prototype has a mirror size of 300μm x 300μm. The experimental measurements show that the prototype can achieve a mechanical rotation of 2.25 degrees (an optical angle of 4.5 degrees) at a driving voltage of 170 volts. A conventional surface micromachined attractive force based rotary micromirror of the same size can only achieve an angle of 0.1~0.2 degree.

  16. DEMES rotary joint: theories and applications

    NASA Astrophysics Data System (ADS)

    Wang, Shu; Hao, Zhaogang; Li, Mingyu; Huang, Bo; Sun, Lining; Zhao, Jianwen

    2017-04-01

    As a kind of dielectric elastomer actuators, dielectric elastomer minimum energy structure (DEMES) can realize large angular deformations by small voltage-induced strains, which make them an attractive candidate for use as biomimetic robotics. Considering the rotary joint is a basic and common component of many biomimetic robots, we have been fabricated rotary joint by DEMES and developed its performances in the past two years. In this paper, we have discussed the static analysis, dynamics analysis and some characteristics of the DEMES rotary joint. Based on theoretical analysis, some different applications of the DEMES rotary joint were presented, such as a flapping wing, a biomimetic fish and a two-legged walker. All of the robots are fabricated by DEMES rotary joint and can realize some basic biomimetic motions. Comparing with traditional rigid robot, the robot based on DEMES is soft and light, so it has advantage on the collision-resistant.

  17. Automated Tape Laying Machine for Composite Structures.

    DTIC Science & Technology

    The invention comprises an automated tape laying machine, for laying tape on a composite structure. The tape laying machine has a tape laying head...neatly cut. The automated tape laying device utilizes narrow width tape to increase machine flexibility and reduce wastage.

  18. Advanced rotary engine studies

    NASA Technical Reports Server (NTRS)

    Jones, C.

    1980-01-01

    A review of rotary engine developments relevant to a stratified charge rotary aircraft engine is presented. Advantages in module size and weight, fuel efficiency, reliability, and multi-fuel capability are discussed along with developments in turbocharging, increased mean effective pressure, improved apex seal/trochoid wear surfacing materials, and high strength and temperature aluminum casting alloys. A carbureted prototype aircraft engine is also described.

  19. Effects of a paraspinal-lumbar tape application during 7 days on the perceived area of tape contact.

    PubMed

    Funk, Stefan; Finke, Roy; Zeh, Stefan; Siebert, Tobias; Puta, Christian

    2017-05-01

    The study aimed to investigate the changes of the perceived area of tape contact during a lumbar tape application that lasted 7 days. Single group, repeated measures study. University research laboratory. Twenty-three healthy collegiate students in sports science. Perceived area of tape contact was collected by preparing a drawing of their individual perceived tape outline into a printed body image. Measurements were obtained immediately after fixation of the tape (day 0), at day 3 and day 7 during application and 5 min after the release of the application (day 7). There was no significant change of the perceived area of tape contact after 3 days of tape application. A significant decrease in the perceived area of tape contact was detected 7 days after application (p < 0.05) and after detaching the tape (p < 0.01) compared to the first measurement. Our results indicate that the perception of the area of tape contact of healthy sport students is decreased at 7 days. This effect could not be observed at 3 days. These results provide relevant information for the use of elastic tapes concerning the duration of application in medical therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Trade-off between Zr Passivation and Sn Doping on Hematite Nanorod Photoanodes for Efficient Solar Water Oxidation: Effects of a ZrO2 Underlayer and FTO Deformation.

    PubMed

    Subramanian, Arunprabaharan; Annamalai, Alagappan; Lee, Hyun Hwi; Choi, Sun Hee; Ryu, Jungho; Park, Jung Hee; Jang, Jum Suk

    2016-08-03

    Herein we report the influence of a ZrO2 underlayer on the PEC (photoelectrochemical) behavior of hematite nanorod photoanodes for efficient solar water splitting. Particular attention was given to the cathodic shift in onset potential and photocurrent enhancement. Akaganite (β-FeOOH) nanorods were grown on ZrO2-coated FTO (fluorine-doped tin oxide) substrates. Sintering at 800 °C transformed akaganite to the hematite (α-Fe2O3) phase and induced Sn diffusion into the crystal structure of hematite nanorods from the FTO substrates and surface migration, shallow doping of Zr atoms from the ZrO2 underlayer. The ZrO2 underlayer-treated photoanode showed better water oxidation performance compared to the pristine (α-Fe2O3) photoanode. A cathodic shift in the onset potential and photocurrent enhancement was achieved by surface passivation and shallow doping of Zr from the ZrO2 underlayer, along with Sn doping from the FTO substrate to the crystal lattice of hematite nanorods. The Zr based hematite nanorod photoanode achieved 1 mA/cm(2) at 1.23 VRHE with a low turn-on voltage of 0.80 VRHE. Sn doping and Zr passivation, as well as shallow doping, were confirmed by XPS, Iph, and M-S plot analyses. Electrochemical impedance spectroscopy revealed that the presence of a ZrO2 underlayer decreased the deformation of FTO substrate, improved electron transfer at the hematite/FTO interface and increased charge-transfer resistance at the electrolyte/hematite interface. This is the first systematic investigation of the effects of Zr passivation, shallow doping, and Sn doping on hematite nanorod photoanodes through application of a ZrO2 underlayer on the FTO substrate.

  1. Tape recorder failure investigation

    NASA Technical Reports Server (NTRS)

    Higgins, M. D.; Loewenthal, S. H.; Carnahan, C. C.; Snyder, G. L.

    1996-01-01

    Two end-item tape recorders lost 4:1 mode data recording mode capability at less than half of their 1 6,000-cycle, 4-year operating life. Subsequent life tests on two spare recorders also experienced 4:1 mode data loss at 8,000 and 11,700 cycles. Tear down inspection after completion of the life tests showed that the tape had worn through the alfesil record and reproduce heads. An investigation was initiated to understand the cause of excessive tape head wear and the reasons why the 4:1 mode data rate, low-speed mode is more damaging than the 1:1 mode data rate, high-speed recording mode. The objective was to establish how operating conditions (tape speed, humidity, temperature, stop/start cycles) affects head life with the goal of extending head life on the remaining in-service tape recorders. Another interest was to explain why an earlier vendor life test showed capability beyond 16,000 cycles.

  2. High Bandwidth Rotary Fast Tool Servos and a Hybrid Rotary/Linear Electromagnetic Actuator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Montesanti, Richard Clement

    2005-09-01

    This thesis describes the development of two high bandwidth short-stroke rotary fast tool servos and the hybrid rotary/linear electromagnetic actuator developed for one of them. Design insights, trade-o® methodologies, and analytical tools are developed for precision mechanical systems, power and signal electronic systems, control systems, normal-stress electromagnetic actuators, and the dynamics of the combined systems.

  3. Man-made rotary nanomotors: a review of recent developments

    NASA Astrophysics Data System (ADS)

    Kim, Kwanoh; Guo, Jianhe; Liang, Z. X.; Zhu, F. Q.; Fan, D. L.

    2016-05-01

    The development of rotary nanomotors is an essential step towards intelligent nanomachines and nanorobots. In this article, we review the concept, design, working mechanisms, and applications of state-of-the-art rotary nanomotors made from synthetic nanoentities. The rotary nanomotors are categorized according to the energy sources employed to drive the rotary motion, including biochemical, optical, magnetic, and electric fields. The unique advantages and limitations for each type of rotary nanomachines are discussed. The advances of rotary nanomotors is pivotal for realizing dream nanomachines for myriad applications including microfluidics, biodiagnosis, nano-surgery, and biosubstance delivery.

  4. Analysis of cache for streaming tape drive

    NASA Technical Reports Server (NTRS)

    Chinnaswamy, V.

    1993-01-01

    A tape subsystem consists of a controller and a tape drive. Tapes are used for backup, data interchange, and software distribution. The backup operation is addressed. During a backup operation, data is read from disk, processed in CPU, and then sent to tape. The processing speeds of a disk subsystem, CPU, and a tape subsystem are likely to be different. A powerful CPU can read data from a fast disk, process it, and supply the data to the tape subsystem at a faster rate than the tape subsystem can handle. On the other hand, a slow disk drive and a slow CPU may not be able to supply data fast enough to keep a tape drive busy all the time. The backup process may supply data to tape drive in bursts. Each burst may be followed by an idle period. Depending on the nature of the file distribution in the disk, the input stream to the tape subsystem may vary significantly during backup. To compensate for these differences and optimize the utilization of a tape subsystem, a cache or buffer is introduced in the tape controller. Most of the tape drives today are streaming tape drives. A streaming tape drive goes into reposition when there is no data from the controller. Once the drive goes into reposition, the controller can receive data, but it cannot supply data to the tape drive until the drive completes its reposition. A controller can also receive data from the host and send data to the tape drive at the same time. The relationship of cache size, host transfer rate, drive transfer rate, reposition, and ramp up times for optimal performance of the tape subsystem are investigated. Formulas developed will also show the advantages of cache watermarks to increase the streaming time of the tape drive, maximum loss due to insufficient cache, tradeoffs between cache and reposition times and the effectiveness of cache on a streaming tape drive due to idle times or interruptions due in host transfers. Several mathematical formulas are developed to predict the performance of the tape

  5. Floating seal system for rotary devices

    DOEpatents

    Banasiuk, Hubert A.

    1983-01-01

    This invention relates to a floating seal system for rotary devices to reduce gas leakage around the rotary device in a duct and across the face of the rotary device to an adjacent duct. The peripheral seal bodies are made of resilient material having a generally U-shaped cross section wherein one of the legs is secured to a support member and the other of the legs forms a contacting seal against the rotary device. The legs of the peripheral seal form an extended angle of intersection of about 10.degree. to about 30.degree. in the unloaded condition to provide even sealing forces around the periphery of the rotary device. The peripheral seal extends around the periphery of the support member except where intersected by radial seals which reduce gas leakage across the face of the rotary device and between adjacent duct portions. The radial seal assembly is fabricated from channel bars, the smaller channel bar being secured to the divider of the support member and a larger inverted rigid floating channel bar having its legs freely movable over the legs of the smaller channel bar forming therewith a tubular channel. A resilient flexible tube is positioned within the tubular channel for substantially its full length to reduce gas leakage across the tubular channel. A spacer extends beyond the face of the floating channel near each end of the floating channel a distance to provide desired clearance between the floating channel and the face of the rotary device.

  6. Floating seal system for rotary devices

    DOEpatents

    Banasiuk, H.A.

    1983-08-23

    This invention relates to a floating seal system for rotary devices to reduce gas leakage around the rotary device in a duct and across the face of the rotary device to an adjacent duct. The peripheral seal bodies are made of resilient material having a generally U-shaped cross section wherein one of the legs is secured to a support member and the other of the legs forms a contacting seal against the rotary device. The legs of the peripheral seal form an extended angle of intersection of about 10[degree] to about 30[degree] in the unloaded condition to provide even sealing forces around the periphery of the rotary device. The peripheral seal extends around the periphery of the support member except where intersected by radial seals which reduce gas leakage across the face of the rotary device and between adjacent duct portions. The radial seal assembly is fabricated from channel bars, the smaller channel bar being secured to the divider of the support member and a larger inverted rigid floating channel bar having its legs freely movable over the legs of the smaller channel bar forming therewith a tubular channel. A resilient flexible tube is positioned within the tubular channel for substantially its full length to reduce gas leakage across the tubular channel. A spacer extends beyond the face of the floating channel near each end of the floating channel a distance to provide desired clearance between the floating channel and the face of the rotary device. 5 figs.

  7. Krytox Lubrication Tape Study. [fluorinated lubricating oil for video tape recorders

    NASA Technical Reports Server (NTRS)

    Lee, F.

    1978-01-01

    The use of Krytox, a fluorinated oil, as a tape surface lubricant was studied for a wideband video tape recorder. In spite of the 5 to 1 head wear reduction credited to the surface lubricant, the resultant head life fell short of the 1500 hour goal.

  8. Rotary mechanical latch

    DOEpatents

    Spletzer, Barry L.; Martinez, Michael A.; Marron, Lisa C.

    2012-11-13

    A rotary mechanical latch for positive latching and unlatching of a rotary device with a latchable rotating assembly having a latching gear that can be driven to latched and unlatched states by a drive mechanism such as an electric motor. A cam arm affixed to the latching gear interfaces with leading and trailing latch cams affixed to a flange within the drive mechanism. The interaction of the cam arm with leading and trailing latch cams prevents rotation of the rotating assembly by external forces such as those due to vibration or tampering.

  9. Digital tape unit test facility software

    NASA Technical Reports Server (NTRS)

    Jackson, J. T.

    1971-01-01

    Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

  10. Man-Made Rotary Nanomotors: A Review of Recent Development

    PubMed Central

    Kim, Kwanoh; Guo, Jianhe; Liang, Z. X.; Zhu, F. Q.; Fan, D. L.

    2016-01-01

    The development rotary nanomotors is an essential step towards intelligent nanomachines and nanorobots. In this article, we review the concept, design, working mechanisms, and applications of the state-of-the-art rotary nanomotors made from synthetic nanoentities. The rotary nanomotors are categorized according to the energy sources employed to drive the rotary motion, including biochemical, optical, magnetic, and electric fields. The unique advantages and limitations for each type of rotary nanomachines are discussed. The advances of rotary nanomotors is pivotal for realizing dream nanomachines for myriad applications including microfluidics, biodiagnosis, nano-surgery, and biosubstance delivery. PMID:27152885

  11. Torque-balanced vibrationless rotary coupling

    DOEpatents

    Miller, Donald M.

    1980-01-01

    This disclosure describes a torque-balanced vibrationless rotary coupling for transmitting rotary motion without unwanted vibration into the spindle of a machine tool. A drive member drives a driven member using flexible connecting loops which are connected tangentially and at diametrically opposite connecting points through a free floating ring.

  12. Quick-release medical tape

    PubMed Central

    Laulicht, Bryan; Langer, Robert; Karp, Jeffrey M.

    2012-01-01

    Medical tape that provides secure fixation of life-sustaining and -monitoring devices with quick, easy, damage-free removal represents a longstanding unmet medical need in neonatal care. During removal of current medical tapes, crack propagation occurs at the adhesive–skin interface, which is also the interface responsible for device fixation. By designing quick-release medical tape to undergo crack propagation between the backing and adhesive layers, we decouple removal and device fixation, enabling dual functionality. We created an ordered adhesive/antiadhesive composite intermediary layer between the medical tape backing and adhesive for which we achieve tunable peel removal force, while maintaining high shear adhesion to secure medical devices. We elucidate the relationship between the spatial ordering of adhesive and antiadhesive regions to create a fully tunable system that achieves strong device fixation and quick, easy, damage-free device removal. We also described ways of neutralizing the residual adhesive on the skin and have observed that thick continuous films of adhesive are easier to remove than the thin islands associated with residual adhesive left by current medical tapes. PMID:23112196

  13. Design of a new separable rotary transformer

    NASA Astrophysics Data System (ADS)

    Gong, X. F.; Zhang, L.; Feng, E. J.

    2017-09-01

    A new-type separable rotary transformer which can be used in rotary steerable drilling is designed to deliver power efficiently from a stationary primary source to a rotary secondary load over a relatively large air gap via magnetic coupling. In this paper, E-type magnetic cores are reasonably distributed so that rotation of the rotary secondary has the least influence on reluctance of magnetic coupling. The influence of different winding layouts and connection modes on self-inductance and coupling coefficient is studied. By analysing the influence of the different geometrical shapes of cores on magnetic path, a design principle is proposed.

  14. Highly precise and compact ultrahigh vacuum rotary feedthrough.

    PubMed

    Aiura, Y; Kitano, K

    2012-03-01

    The precision and rigidity of compact ultrahigh vacuum (UHV) rotary feedthroughs were substantially improved by preparing and installing an optimal crossed roller bearing with mounting holes. Since there are mounting holes on both the outer and inner races, the bearing can be mounted directly to rotary and stationary stages without any fixing plates and housing. As a result, it is possible to increase the thickness of the bearing or the size of the rolling elements in the bearing without increasing the distance between the rotating and fixing International Conflat flanges of the UHV rotary feedthrough. Larger rolling elements enhance the rigidity of the UHV rotary feedthrough. Moreover, owing to the structure having integrated inner and outer races and mounting holes, the performance is almost entirely unaffected by the installation of the bearing, allowing for a precise optical encoder to be installed in the compact UHV rotary feedthrough. Using position feedback via a worm gear system driven by a stepper motor and a precise rotary encoder, the actual angle of the compact UHV rotary feedthrough can be controlled with extremely high precision.

  15. Highly precise and compact ultrahigh vacuum rotary feedthrough

    NASA Astrophysics Data System (ADS)

    Aiura, Y.; Kitano, K.

    2012-03-01

    The precision and rigidity of compact ultrahigh vacuum (UHV) rotary feedthroughs were substantially improved by preparing and installing an optimal crossed roller bearing with mounting holes. Since there are mounting holes on both the outer and inner races, the bearing can be mounted directly to rotary and stationary stages without any fixing plates and housing. As a result, it is possible to increase the thickness of the bearing or the size of the rolling elements in the bearing without increasing the distance between the rotating and fixing International Conflat flanges of the UHV rotary feedthrough. Larger rolling elements enhance the rigidity of the UHV rotary feedthrough. Moreover, owing to the structure having integrated inner and outer races and mounting holes, the performance is almost entirely unaffected by the installation of the bearing, allowing for a precise optical encoder to be installed in the compact UHV rotary feedthrough. Using position feedback via a worm gear system driven by a stepper motor and a precise rotary encoder, the actual angle of the compact UHV rotary feedthrough can be controlled with extremely high precision.

  16. Tracer sensitive tapes

    NASA Technical Reports Server (NTRS)

    Burrows, W. H.; Burrows, W. H.

    1971-01-01

    A leak detection system has been developed, consisting of a tape that can be wrapped around possible leak sites on a system pressurized with air or gaseous nitrogen. Carbon monoxide, at a level of 100 to 1000 parts per million is used as a trace gas in the pressurized system. The sensitive element of the tape is palladium chloride supported on specially prepared silica gel and specially dried. At a CO level of 100 ppm and a leak rate of 10-20 ml/hr, discoloration of the sensitive element is observed in 1.5 to 3 min. The tape and trace gas are compatible with aerospace hardware, safe to handle, and economically reasonable to produce and handle.

  17. Rotary engine research

    NASA Astrophysics Data System (ADS)

    1992-06-01

    A development history is presented for NASA's 1983-1991 Rotary Engine Enablement Program, emphasizing the CFD approaches to various problems that were instituted from 1987 to the end of the program. In phase I, a test rig was built to intensively clarify and characterize the stratified-charge rotary engine concept. In phase II, a high pressure, electronically controlled fuel injection system was tested. In phase III, the testing of improved fuel injectors led to the achievement of the stipulated 5 hp/cu inch specific power goal. CFD-aided design of advanced rotor-pocket shapes led to additional performance improvements.

  18. Effect of tape recording on perturbation measures.

    PubMed

    Jiang, J; Lin, E; Hanson, D G

    1998-10-01

    Tape recorders have been shown to affect measures of voice perturbation. Few studies, however, have been conducted to quantitatively justify the use or exclusion of certain types of recorders in voice perturbation studies. This study used sinusoidal and triangular waves and synthesized vowels to compare perturbation measures extracted from directly digitized signals with those recorded and played back through various tape recorders, including 3 models of digital audio tape recorders, 2 models of analog audio cassette tape recorders, and 2 models of video tape recorders. Signal contamination for frequency perturbation values was found to be consistently minimal with digital recorders (percent jitter = 0.01%-0.02%), mildly increased with video recorders (0.05%-0.10%), moderately increased with a high-quality analog audio cassette tape recorder (0.15%), and most prominent with a low-quality analog audio cassette tape recorder (0.24%). Recorder effect on amplitude perturbation measures was lowest in digital recorders (percent shimmer = 0.09%-0.20%), mildly to moderately increased in video recorders and a high-quality analog audio cassette tape recorder (0.25%-0.45%), and most prominent in a low-quality analog audio cassette tape recorder (0.98%). The effect of cassette tape material, length of spooled tape, and duration of analysis were also tested and are discussed.

  19. Rotary Power Transformer and Inverter Circuit

    NASA Technical Reports Server (NTRS)

    Mclyman, C. W. T.; Bridgeforth, A. O.

    1985-01-01

    Noise lower than with sliprings. Rotary transformer transfers electric power across rotary joint. No wearing contacts, no contact noise, and no contamination from lubricants or wear debris. Because additional inductor not required, size and complexity of circuit reduced considerably.

  20. Enhancing contrast of fingerprints on plastic tape.

    PubMed

    Steele, Charles A; Ball, Mikki S

    2003-11-01

    Many of the currently available fingerprinting methods have limited ability to visualize fingerprints on plastic tape without expensive equipment or significant handling of the sample. This is especially true for visualizing fingerprints on black electrical tape. This study sought a hands-off method to produce easy visualization of fingerprints on different types of plastic tape, including black electrical tape, without the need for expensive equipment. The methods selected were to sublime disperse dyes into the tape, both with and without the fuming of cyanoacrylate, everywhere except for where the fingerprint was applied. The resulting color contrasts provided enough differentiation to visualize fingerprints on plastic tape under ambient light. Sequential fuming with cyanoacrylate followed by disperse dyes provided the best visualizations on all tapes, and cyanoacrylate followed by disperse yellow 211 clearly visualized fingerprints on black electrical tape.

  1. EROS to universal tape conversion processor

    NASA Technical Reports Server (NTRS)

    Obrien, S. O. (Principal Investigator)

    1980-01-01

    The function of the EROS processor is to allow a user to select a specific area from a full frame LANDSAT image which is written on tape in the EROS format. The area of interest is read from the EROS formatted tape and converted to the JSC Universal format and written onto another tape. This tape can then be read by the IMDACS processing system and normal analysis can be performed.

  2. 21 CFR 872.4840 - Rotary scaler.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... DENTAL DEVICES Surgical Devices § 872.4840 Rotary scaler. (a) Identification. A rotary scaler is an abrasive device intended to be attached to a powered handpiece to remove calculus deposits from teeth during dental cleaning and periodontal (gum) therapy. (b) Classification. Class II. ...

  3. 21 CFR 872.4840 - Rotary scaler.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... DENTAL DEVICES Surgical Devices § 872.4840 Rotary scaler. (a) Identification. A rotary scaler is an abrasive device intended to be attached to a powered handpiece to remove calculus deposits from teeth during dental cleaning and periodontal (gum) therapy. (b) Classification. Class II. ...

  4. 21 CFR 872.4840 - Rotary scaler.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... DENTAL DEVICES Surgical Devices § 872.4840 Rotary scaler. (a) Identification. A rotary scaler is an abrasive device intended to be attached to a powered handpiece to remove calculus deposits from teeth during dental cleaning and periodontal (gum) therapy. (b) Classification. Class II. ...

  5. 21 CFR 872.4840 - Rotary scaler.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... DENTAL DEVICES Surgical Devices § 872.4840 Rotary scaler. (a) Identification. A rotary scaler is an abrasive device intended to be attached to a powered handpiece to remove calculus deposits from teeth during dental cleaning and periodontal (gum) therapy. (b) Classification. Class II. ...

  6. 21 CFR 872.4840 - Rotary scaler.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... DENTAL DEVICES Surgical Devices § 872.4840 Rotary scaler. (a) Identification. A rotary scaler is an abrasive device intended to be attached to a powered handpiece to remove calculus deposits from teeth during dental cleaning and periodontal (gum) therapy. (b) Classification. Class II. ...

  7. ICI optical data storage tape

    NASA Technical Reports Server (NTRS)

    Mclean, Robert A.; Duffy, Joseph F.

    1992-01-01

    Optical data storage tape is now a commercial reality. The world's first successful development of a digital optical tape system is complete. This is based on the Creo 1003 optical tape recorder with ICI 1012 write-once optical tape media. Flexible optical media offers many benefits in terms of manufacture; for a given capital investment, continuous, web-coating techniques produce more square meters of media than batch coating. The coated layers consist of a backcoat on the non-active side; on the active side there is a subbing layer, then reflector, dye/polymer, and transparent protective overcoat. All these layers have been tailored for ease of manufacture and specific functional characteristics.

  8. System and method for calibrating a rotary absolute position sensor

    NASA Technical Reports Server (NTRS)

    Davis, Donald R. (Inventor); Permenter, Frank Noble (Inventor); Radford, Nicolaus A (Inventor)

    2012-01-01

    A system includes a rotary device, a rotary absolute position (RAP) sensor generating encoded pairs of voltage signals describing positional data of the rotary device, a host machine, and an algorithm. The algorithm calculates calibration parameters usable to determine an absolute position of the rotary device using the encoded pairs, and is adapted for linearly-mapping an ellipse defined by the encoded pairs to thereby calculate the calibration parameters. A method of calibrating the RAP sensor includes measuring the rotary position as encoded pairs of voltage signals, linearly-mapping an ellipse defined by the encoded pairs to thereby calculate the calibration parameters, and calculating an absolute position of the rotary device using the calibration parameters. The calibration parameters include a positive definite matrix (A) and a center point (q) of the ellipse. The voltage signals may include an encoded sine and cosine of a rotary angle of the rotary device.

  9. ProTaper rotary instrument fracture during root canal preparation: a comparison between rotary and hybrid techniques.

    PubMed

    Farid, Huma; Khan, Farhan Raza; Rahman, Munawar

    2013-03-01

    This study aimed to compare the frequency of ProTaper rotary instrument fracture with rotary (conventional) and hybrid (rotary and hand files) canal preparation techniques. Secondary objectives were to determine whether there was an association of ProTaper file fracture with the canal curvature and to compare the mean time required for canal preparation in the two techniques. An in vitro experiment was conducted on 216 buccal canals of extracted maxillary and mandibular first molars. After creating an access cavity and a glide path for each canal, a periapical radiograph was taken and the canal curvature was measured with Schneider's technique. The canals were then randomly divided into Group A (rotary technique) and Group B (hybrid technique). The length of ProTaper files were measured before and after each canal preparation. Time taken for each canal preparation was recorded. A total of seven ProTaper files fractured in Group A (P=0.014) in canals with a curvature >25 degrees (P<0.001). The mean time taken for preparation of the root canals was 104.04 sec (± 55.7 sec) in Group A versus 122.88 sec (± 41.67 sec) in Group B (P=0.007). In the teeth studied, the hybrid technique of root canal preparation with ProTaper rotary files, although time consuming, was safer in canals having a curvature greater than 25 degrees.

  10. A Comparison of Apical Bacterial Extrusion in Manual, ProTaper Rotary, and One Shape Rotary Instrumentation Techniques.

    PubMed

    Mittal, Rakesh; Singla, Meenu G; Garg, Ashima; Dhawan, Anu

    2015-12-01

    Apical extrusion of irrigants and debris is an inherent limitation associated with cleaning and shaping of root canals and has been studied extensively because of its clinical relevance as a cause of flare-ups. Many factors affect the amount of extruded intracanal materials. The purpose of this study was to assess the bacterial extrusion by using manual, multiple-file continuous rotary system (ProTaper) and single-file continuous rotary system (One Shape). Forty-two human mandibular premolars were inoculated with Enterococcus faecalis by using a bacterial extrusion model. The teeth were divided into 3 experimental groups (n = 12) and 1 control group (n = 6). The root canals of experimental groups were instrumented according to the manufacturers' instructions by using manual technique, ProTaper rotary system, or One Shape rotary system. Sterilized saline was used as an irrigant, and bacterial extrusion was quantified as colony-forming units/milliliter. The results obtained were statistically analyzed by using one-way analysis of variance for intergroup comparison and post hoc Tukey test for pair-wise comparison. The level for accepting statistical significance was set at P < .05. All the instrumentation techniques resulted in bacterial extrusion, with manual step-back technique exhibiting significantly more bacterial extrusion than the engine-driven systems. Of the 2 engine-driven systems, ProTaper rotary extruded significantly more bacteria than One Shape rotary system (P < .05). The engine-driven nickel-titanium systems were associated with less apical extrusion. The instrument design may play a role in amount of extrusion. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  11. Design study of a high power rotary transformer

    NASA Technical Reports Server (NTRS)

    Weinberger, S. M.

    1982-01-01

    A design study was made on a rotary transformer for transferring electrical power across a rotating spacecraft interface. The analysis was performed for a 100 KW, 20 KHz unit having a ""pancake'' geometry. The rotary transformer had a radial (vertical) gap and consisted of 4-25 KW modules. It was assumed that the power conditioning comprised of a Schwarz resonant circuit with a 20 KHz switching frequency. The rotary transformer, mechanical and structural design, heat rejection system and drive mechanism which provide a complete power transfer device were examined. The rotary transformer losses, efficiency, weight and size were compared with an axial (axial symmetric) gap transformer having the same performance requirements and input characteristics which was designed as part of a previous program. The ""pancake'' geometry results in a heavier rotary transformer primarily because of inefficient use of the core material. It is shown that the radial gap rotary transformer is a feasible approach for the transfer of electrical power across a rotating interface and can be implemented using presently available technology.

  12. Rotary adsorbers for continuous bulk separations

    DOEpatents

    Baker, Frederick S [Oak Ridge, TN

    2011-11-08

    A rotary adsorber for continuous bulk separations is disclosed. The rotary adsorber includes an adsorption zone in fluid communication with an influent adsorption fluid stream, and a desorption zone in fluid communication with a desorption fluid stream. The fluid streams may be gas streams or liquid streams. The rotary adsorber includes one or more adsorption blocks including adsorbent structure(s). The adsorbent structure adsorbs the target species that is to be separated from the influent fluid stream. The apparatus includes a rotary wheel for moving each adsorption block through the adsorption zone and the desorption zone. A desorption circuit passes an electrical current through the adsorbent structure in the desorption zone to desorb the species from the adsorbent structure. The adsorbent structure may include porous activated carbon fibers aligned with their longitudinal axis essentially parallel to the flow direction of the desorption fluid stream. The adsorbent structure may be an inherently electrically-conductive honeycomb structure.

  13. An overview of the NASA rotary engine research program

    NASA Technical Reports Server (NTRS)

    Meng, P. R.; Hady, W. F.

    1984-01-01

    A brief overview and technical highlights of the research efforts and studies on rotary engines over the last several years at the NASA Lewis Research Center are presented. The test results obtained from turbocharged rotary engines and preliminary results from a high performance single rotor engine were discussed. Combustion modeling studies of the rotary engine and the use of a Laser Doppler Velocimeter to confirm the studies were examined. An in-house program in which a turbocharged rotary engine was installed in a Cessna Skymaster for ground test studies was reviewed. Details are presented on single rotor stratified charge rotary engine research efforts, both in-house and on contract.

  14. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, Eric B.; Muller, Albert C.

    1984-01-01

    A high voltage oil-impregnated electrical cable with fully polymer taped insulation operable to 765 kV. Biaxially oriented, specially processed, polyethylene, polybutene or polypropylene tape with an embossed pattern is wound in multiple layers over a conductive core with a permeable screen around the insulation. Conventional oil which closely matches the dielectric constant of the tape is used, and the cable can be impregnated after field installation because of its excellent impregnation characteristics.

  15. Rotary Stirling-Cycle Engine And Generator

    NASA Technical Reports Server (NTRS)

    Chandler, Joseph A.

    1990-01-01

    Proposed electric-power generator comprises three motor generators coordinated by microprocessor and driven by rotary Stirling-cycle heat engine. Combination offers thermodynamic efficiency of Stirling cycle, relatively low vibration, and automatic adjustment of operating parameters to suit changing load on generator. Rotary Stirling cycle engine converts heat to power via compression and expansion of working gas between three pairs of rotary pistons on three concentric shafts in phased motion. Three motor/generators each connected to one of concentric shafts, can alternately move and be moved by pistons. Microprocessor coordinates their operation, including switching between motor and generator modes at appropriate times during each cycle.

  16. Kinematics of Tape Recording.

    ERIC Educational Resources Information Center

    Coleman, J. J.

    1982-01-01

    Describes mathematics of the nonliner relationships between a constant-speed, capstan-driven magnetic tape transport mechanism and a constant-angular-velocity take-up reel. The relationship, derived from the sum of a partial, serves in recognition of a finite tape. Thickness can serve as an example of rotational kinematics. (Author/SK)

  17. Rotary endodontics in primary teeth - A review.

    PubMed

    George, Sageena; Anandaraj, S; Issac, Jyoti S; John, Sheen A; Harris, Anoop

    2016-01-01

    Endodontic treatment in primary teeth can be challenging and time consuming, especially during canal preparation, which is considered one of the most important steps in root canal therapy. The conventional instrumentation technique for primary teeth remains the "gold-standard" over hand instrumentation, which makes procedures much more time consuming and adversely affects both clinicians and patients. Recently nickel-titanium (Ni-Ti) rotary files have been developed for use in pediatric endodontics. Using rotary instruments for primary tooth pulpectomies is cost effective and results in fills that are consistently uniform and predictable. This article reviews the use of nickel-titanium rotary files as root canal instrumentation in primary teeth. The pulpectomy technique is described here according to different authors and the advantages and disadvantages of using rotary files are discussed.

  18. Light-Curing Adhesive Repair Tapes

    NASA Technical Reports Server (NTRS)

    Allred, Ronald; Haight, Andrea Hoyt

    2009-01-01

    Adhesive tapes, the adhesive resins of which can be cured (and thereby rigidized) by exposure to ultraviolet and/or visible light, are being developed as repair patch materials. The tapes, including their resin components, consist entirely of solid, low-outgassing, nonhazardous or minimally hazardous materials. They can be used in air or in vacuum and can be cured rapidly, even at temperatures as low as -20 C. Although these tapes were originally intended for use in repairing structures in outer space, they can also be used on Earth for quickly repairing a wide variety of structures. They can be expected to be especially useful in situations in which it is necessary to rigidize tapes after wrapping them around or pressing them onto the parts to be repaired.

  19. FGGE/ERBZ tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The FGGE/ERBZ tape contains 5 parameters which are extracted and reformatted from the Nimbus-7 ERB Zonal Means Tape. There are three types of files on a FGGE/ERBZ tape: a tape header file, and data files. Physical characteristics, gross format, and file specifications are given. A sample tape check/document printout (shipping letter) is included.

  20. FGGE/ERBM tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The Nimbus-7 FGGE/ERBM tape contains 27 ERB parameters which are extracted and reformatted from the Nimbus-7 ERB-MATRIX tape. There are four types of files on a FGGE/ERBM tape: a test file; tape-header file which describes the data set characteristics and the contents of the tape; a grid-descriptor file which contains the information of the ERB scanning channel target number and their associated latitude limits and longitude intervals; and one or more data files. A single end-of-file (EOF) tape mark is written after each file, and two EOF marks are written after the last data file on the tape.

  1. Caught (Unfortunately) on Tape

    ERIC Educational Resources Information Center

    Young, Jeffrey R.

    2009-01-01

    Recording class sessions so students can view them online is becoming routine on many campuses. But all that taping can lead to "uh-oh moments," such as when a professor's joke about the college dean ends up on YouTube, or a private comment to a student after class is inadvertently broadcast. Some lecture bloopers caught on tape are…

  2. Compact rotary sequencer

    NASA Technical Reports Server (NTRS)

    Appleberry, W. T.

    1980-01-01

    Rotary sequencer is assembled from conventional planetary differential gearset and latching mechanism utilizing inputs and outputs which are coaxial. Applications include automated production-line equipment in home appliances and in vehicles.

  3. Rotary drum separator system

    NASA Technical Reports Server (NTRS)

    Barone, Michael R. (Inventor); Murdoch, Karen (Inventor); Scull, Timothy D. (Inventor); Fort, James H. (Inventor)

    2009-01-01

    A rotary phase separator system generally includes a step-shaped rotary drum separator (RDS) and a motor assembly. The aspect ratio of the stepped drum minimizes power for both the accumulating and pumping functions. The accumulator section of the RDS has a relatively small diameter to minimize power losses within an axial length to define significant volume for accumulation. The pumping section of the RDS has a larger diameter to increase pumping head but has a shorter axial length to minimize power losses. The motor assembly drives the RDS at a low speed for separating and accumulating and a higher speed for pumping.

  4. Solar heated rotary kiln

    DOEpatents

    Shell, Pamela K.

    1984-01-01

    A solar heated rotary kiln utilized for decomposition of materials, such as zinc sulfate. The rotary kiln has an open end and is enclosed in a sealed container having a window positioned for directing solar energy into the open end of the kiln. The material to be decomposed is directed through the container into the kiln by a feed tube. The container is also provided with an outlet for exhaust gases and an outlet for spent solids, and rests on a tiltable base. The window may be cooled and kept clear of debris by coolant gases.

  5. Solar-heated rotary kiln

    DOEpatents

    Shell, P.K.

    1982-04-14

    A solar heated rotary kiln utilized for decomposition of materials, such as zinc sulfate is disclosed. The rotary kiln has an open end and is enclosed in a sealed container having a window positioned for directing solar energy into the open end of the kiln. The material to be decomposed is directed through the container into the kiln by a feed tube. The container is also provided with an outlet for exhaust gases and an outlet for spent solids, and rests on a tiltable base. The window may be cooled and kept clear of debris by coolant gases.

  6. Effectiveness of functional ankle taping for judo athletes: a comparison between judo bandaging and taping.

    PubMed Central

    Yamamoto, T; Kigawa, A; Xu, T

    1993-01-01

    This study was conducted to compare the effectiveness of the traditional method of ankle bandaging and the new method of ankle taping for judo athletes in Japan, and to introduce a functionally effective taping method for judo players. Four university judo athletes with ankle instability were selected to undertake radiography of the ankles before and after exercise, with bandaging at one time and taping at the other. Talar tilt (TT) angles were measured in order to compare the ankle-supporting effects. The results showed that the old ankle bandaging method had no role in eliminating the talar tilt during judo practice. In contrast, the new taping method was more effective in eliminating the talar tilt and supporting the involved ankles both mechanically and functionally. Images Figure 1 Figure 2 Figure 3 PMID:8358580

  7. Immediate Effects of Ankle Balance Taping with Kinesiology Tape for Amateur Soccer Players with Lateral Ankle Sprain: A Randomized Cross-Over Design

    PubMed Central

    Kim, Myoung Kwon; Shin, Young Jun

    2017-01-01

    Background The objective of this study was to investigate the immediate effect on gait function when ankle balance taping is applied to amateur soccer players with lateral ankle sprain. Material/Methods A cross-over randomized design was used. Twenty-two soccer players with an ankle sprain underwent 3 interventions in a random order. Subjects were randomly assigned to ankle balance taping, placebo taping, and no taping groups. The assessment was performed using the GAITRite portable walkway system, which records the location and timing of each footfall during ambulation. Results Significant differences were found in the velocity, step length, stride length, and H-H base support among the 3 different taping methods (p<0.05). The ankle balance taping group showed significantly greater velocity, step length, and stride length in comparison to the placebo and no taping group. The ankle balance taping group showed a statistically significant decrease (p<0.05) in the H-H base support compared to the placebo and no taping groups, and the placebo group showed significantly greater velocity in comparison to the no taping group (p<0.05). Conclusions We conclude that ankle balance taping that uses kinesiology tape instantly increased the walking ability of amateur soccer players with lateral ankle sprain. Therefore, ankle balance taping is a useful alternative to prevent and treat ankle sprain of soccer players. PMID:29158472

  8. Well-isolated FePt grains with high coercivity on TiN underlayers for heat-assisted magnetic recording media

    NASA Astrophysics Data System (ADS)

    Santos, Tiffany; Jain, Shikha; Hirotsune, Akemi; Hellwig, Olav

    2015-03-01

    MgO is the underlayer material of choice for granular FePt thin film media for heat assisted magnetic recording, because MgO (001) seeds L10-ordered FePt with c-axis perpendicular to the film plane and high perpendicular magnetic anisotropy. MgO is also an effective diffusion barrier between the FePt grains and the metallic underlayers beneath the MgO. However, there are possible concerns associated with using MgO in the media structure. MgO is highly sensitive to moisture, and hydration of MgO could potentially degrade film properties. In addition, many particulates are incorporated into the film during the RF-sputter process, which can be sources of delamination, pinholes and damage to the low-flying recording heads. TiN is an attractive alternative to MgO because it is chemically and mechanically robust, and TiN can be DC-sputtered, which produces fewer particles and has a faster deposition rate. Even though TiN has the same rocksalt crystal structure and lattice constant as MgO, the higher surface energy of TiN causes more wetting of the FePt grains on the TiN surface. As a result, deposition of granular FePt on TiN most often produces inter-connected, worm-like grains with low coercivity. We will show that by optimizing the deposition of FePt and segregant material on the TiN underlayer, we are able to fabricate FePt media with well-isolated grains and high coercivity reaching nearly 4 Tesla. In addition, the FePt has excellent structural properties with a high degree of L10 atomic ordering and minimal c-axis in-plane oriented grains.

  9. High density tape/head interface study

    NASA Technical Reports Server (NTRS)

    Csengery, L. C.

    1983-01-01

    The high energy (H sub c approximately or = to 650 oersteds) tapes and high track density (84 tracks per inch) heads investigated had, as its goal, the definition of optimum combinations of head and tape, including the control required of their interfacial dynamics that would enable the manufacture of high rate (150 Mbps) digital tape recorders for unattended space flight.

  10. Production of Synthetic Phosphoanhydrite and Its Use as a Binder in Self-Leveling Underlayments (SLU).

    PubMed

    Schaefer, Cecília Ogliari; Cheriaf, Malik; Rocha, Janaíde Cavalcante

    2017-08-17

    An experimental study was conducted to investigate the potential use of phosphogypsum (PG) to produce self-leveling underlayments. The study was designed in two stages. Initially a phosphoanhydrite (PA) was produced by heating phosphogypsum at temperatures of 350 °C, 450 °C, 550 °C, and 650 °C. Two periods of heating were applied (2 and 4 h). The formation of anhydrite was determined by thermogravimetric analysis (DTA-TG) and confirmed by X-ray diffraction (XRD). The results show that anhydrite II was obtained at temperatures above 450 °C, and at higher calcination temperatures the PA solubility was lower. In the second stage of this research, the PA was used in self-leveling underlayments as the main binder in the ternary system comprised of calcium sulfate, calcium aluminate cement, and Portland cement. Self-leveling mortar screeds produced using PA (550 °C/4 h) and PA (650 °C/4 h) showed the best performance in terms of mechanical strength and no degradation was observed after immersion and immersion-drying tests. The formation of ettringite, identified by scanning electron microscopy (SEM), may have contributed to these results. Morphological changes were studied using the scanning electron microscopy (SEM) technique.

  11. Production of Synthetic Phosphoanhydrite and Its Use as a Binder in Self-Leveling Underlayments (SLU)

    PubMed Central

    Schaefer, Cecília Ogliari; Cheriaf, Malik

    2017-01-01

    An experimental study was conducted to investigate the potential use of phosphogypsum (PG) to produce self-leveling underlayments. The study was designed in two stages. Initially a phosphoanhydrite (PA) was produced by heating phosphogypsum at temperatures of 350 °C, 450 °C, 550 °C, and 650 °C. Two periods of heating were applied (2 and 4 h). The formation of anhydrite was determined by thermogravimetric analysis (DTA-TG) and confirmed by X-ray diffraction (XRD). The results show that anhydrite II was obtained at temperatures above 450 °C, and at higher calcination temperatures the PA solubility was lower. In the second stage of this research, the PA was used in self-leveling underlayments as the main binder in the ternary system comprised of calcium sulfate, calcium aluminate cement, and Portland cement. Self-leveling mortar screeds produced using PA (550 °C/4 h) and PA (650 °C/4 h) showed the best performance in terms of mechanical strength and no degradation was observed after immersion and immersion-drying tests. The formation of ettringite, identified by scanning electron microscopy (SEM), may have contributed to these results. Morphological changes were studied using the scanning electron microscopy (SEM) technique. PMID:28817091

  12. Split Coil Forms for Rotary Transformers

    NASA Technical Reports Server (NTRS)

    Mclyman, C. W. T.

    1982-01-01

    Split cores for rotor and stator windings of rotary transformer mounted around their respective coils (which are in bobbins) and cemented together. This arrangement simplifies winding of stator coil to go in a slot in inner diameter of stator coil. One practical application of rotary transformers fabricated according to this technique is for centrifuges, in which conventional sliprings are of uncertain reliability.

  13. A prospective randomized blister prevention trial assessing paper tape in endurance distances (Pre-TAPED).

    PubMed

    Lipman, Grant S; Ellis, Mark A; Lewis, Erica J; Waite, Brandee L; Lissoway, John; Chan, Garrett K; Krabak, Brian J

    2014-12-01

    Friction foot blisters are a common injury occurring in up to 39% of marathoners, the most common injury in adventure racing, and represent more than 70% of medical visits in multi-stage ultramarathons. The goal of the study was to determine whether paper tape could prevent foot blisters in ultramarathon runners. This prospective randomized trial was undertaken during RacingThePlanet 155-mile (250-km), 7-day self-supported ultramarathons in China, Australia, Egypt, Chile, and Nepal in 2010 and 2011. Paper tape was applied prerace to one randomly selected foot, with the untreated foot acting as the own control. The study end point was development of a hot spot or blister on any location of either foot. One hundred thirty-six participants were enrolled with 90 (66%) having completed data for analysis. There were 36% women, with a mean age of 40 ± 9.4 years (range, 25-40 years) and pack weight of 11 ± 1.8 kg (range, 8-16 kg). All participants developed blisters, with 89% occurring by day 2 and 59% located on the toes. No protective effect was observed by the intervention (47 versus 35; 52% versus 39%; P = .22), with fewer blisters occurring around the tape on the experimental foot than under the tape (23 vs 31; 25.6% versus 34.4%), yet 84% of study participants when queried would choose paper tape for blister prevention in the future. Although paper tape was not found to be significantly protective against blisters, the intervention was well tolerated with high user satisfaction. Copyright © 2014 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  14. Design and implementation of scalable tape archiver

    NASA Technical Reports Server (NTRS)

    Nemoto, Toshihiro; Kitsuregawa, Masaru; Takagi, Mikio

    1996-01-01

    In order to reduce costs, computer manufacturers try to use commodity parts as much as possible. Mainframes using proprietary processors are being replaced by high performance RISC microprocessor-based workstations, which are further being replaced by the commodity microprocessor used in personal computers. Highly reliable disks for mainframes are also being replaced by disk arrays, which are complexes of disk drives. In this paper we try to clarify the feasibility of a large scale tertiary storage system composed of 8-mm tape archivers utilizing robotics. In the near future, the 8-mm tape archiver will be widely used and become a commodity part, since recent rapid growth of multimedia applications requires much larger storage than disk drives can provide. We designed a scalable tape archiver which connects as many 8-mm tape archivers (element archivers) as possible. In the scalable archiver, robotics can exchange a cassette tape between two adjacent element archivers mechanically. Thus, we can build a large scalable archiver inexpensively. In addition, a sophisticated migration mechanism distributes frequently accessed tapes (hot tapes) evenly among all of the element archivers, which improves the throughput considerably. Even with the failures of some tape drives, the system dynamically redistributes hot tapes to the other element archivers which have live tape drives. Several kinds of specially tailored huge archivers are on the market, however, the 8-mm tape scalable archiver could replace them. To maintain high performance in spite of high access locality when a large number of archivers are attached to the scalable archiver, it is necessary to scatter frequently accessed cassettes among the element archivers and to use the tape drives efficiently. For this purpose, we introduce two cassette migration algorithms, foreground migration and background migration. Background migration transfers cassettes between element archivers to redistribute frequently accessed

  15. Structural modeling of HTS tapes and cables

    NASA Astrophysics Data System (ADS)

    Allen, N. C.; Chiesa, L.; Takayasu, M.

    2016-12-01

    Structural finite element analysis (FEA) has been used as an insightful tool to investigate the electromechanical behavior of HTS REBCO tapes and twisted stacked-tape cables under tension, torsion, bending and combined loads. A novel technique was developed for modeling the layered composite structure of the 2G tapes with structural solid-shell elements in ANSYS®. The FEA models produced detailed strain information for the REBCO superconducting layer which was then paired with an analytical model to predict the critical current performance of the 2G HTS tapes under various loads. Two commercially available HTS tapes (SuperPower and SuNAM) under tension, torsion and combined tension-torsion were first analyzed with FEA and compared with available experimental results at 77 K. A sharp critical current degradation was experienced at the yield strength of the tapes under tension and below a 100 mm twist-pitch under torsion. Combined tension-torsion loads had a more gradual degradation of critical current for twist-pitches of 115 mm or shorter but had a negligible difference compared to pure tension for longer twist-pitches. Using the structural solid-shell technique for modeling 2G tapes in ANSYS®, an FEA methodology for simulating full scale three-dimensional HTS stacked-tape cables under pure bending was created. A model of a Twisted-Stacked Tape Cable (TSTC), a configuration first proposed at MIT, was initially developed and then adapted to the slotted-core HTS Cable-In-Conduit Conductor produced by the ENEA laboratory in Italy. The numerical axial strain of the HTS REBCO tapes within the cables as calculated by FEA were found to agree with an analytical model for two cases: perfect-slip (frictionless) and no-slip (bonded). The ENEA CICC model was also compared with recent experimental critical current data at 77 K and was found to match best using a low friction coefficient of 0.02 indicating that the tapes within the cable freely slide with respect to each other

  16. Micro-Teaching Tapes in Anatomy and Physiology.

    ERIC Educational Resources Information Center

    Stencel, John E.

    1981-01-01

    Outlines the development and use of micro-teaching tapes as a means of supplemental instruction for college anatomy and physiology classes. Tapes include brief explanations of difficult concepts taken from lectures as students listen to cassette tapes and fill in blanks, or answer questions. (DS)

  17. Lunar Data Node: Apollo Data Restoration and Archiving Update

    NASA Technical Reports Server (NTRS)

    Williams, David R.; Hills, Howard K.; Guiness, Edward A.; Taylor, Patrick T.; McBride, Marie Julia

    2013-01-01

    The Lunar Data Node (LDN) of the Planetary Data System (PDS) is responsible for the restoration and archiving of Apollo data. The LDN is located at the National Space Science Data Center (NSSDC), which holds much of the extant Apollo data on microfilm, microfiche, hard-copy documents, and magnetic tapes in older formats. The goal of the restoration effort is to convert the data into user-accessible PDS formats, create a full set of explanatory supporting data (metadata), archive the full data sets through PDS, and post the data online at the PDS Geosciences Node. This will both enable easy use of the data by current researchers and ensure that the data and metadata are securely preserved for future use. We are also attempting to locate and preserve Apollo data which were never archived at NSSDC. We will give a progress report on the data sets we have been restoring and future work.

  18. Strategy for robot motion and path planning in robot taping

    NASA Astrophysics Data System (ADS)

    Yuan, Qilong; Chen, I.-Ming; Lembono, Teguh Santoso; Landén, Simon Nelson; Malmgren, Victor

    2016-06-01

    Covering objects with masking tapes is a common process for surface protection in processes like spray painting, plasma spraying, shot peening, etc. Manual taping is tedious and takes a lot of effort of the workers. The taping process is a special process which requires correct surface covering strategy and proper attachment of the masking tape for an efficient surface protection. We have introduced an automatic robot taping system consisting of a robot manipulator, a rotating platform, a 3D scanner and specially designed taping end-effectors. This paper mainly talks about the surface covering strategies for different classes of geometries. The methods and corresponding taping tools are introduced for taping of following classes of surfaces: Cylindrical/extended surfaces, freeform surfaces with no grooves, surfaces with grooves, and rotational symmetrical surfaces. A collision avoidance algorithm is introduced for the robot taping manipulation. With further improvements on segmenting surfaces of taping parts and tape cutting mechanisms, such taping solution with the taping tool and the taping methodology can be combined as a very useful and practical taping package to assist humans in this tedious and time costly work.

  19. Chemical News Via Audio Tapes: Chemical Industry News

    ERIC Educational Resources Information Center

    Hanford, W. E.; And Others

    1972-01-01

    Tape coverage of internal R&D news now has a broader scope with improved features. A new tape series covering external news of broad interest has been initiated. The use of tape in a Continuing Education Program is discussed as the future plans for expanding the audio tape program. (1 reference) (Author)

  20. Stratified charge rotary engine combustion studies

    NASA Astrophysics Data System (ADS)

    Shock, H.; Hamady, F.; Somerton, C.; Stuecken, T.; Chouinard, E.; Rachal, T.; Kosterman, J.; Lambeth, M.; Olbrich, C.

    1989-07-01

    Analytical and experimental studies of the combustion process in a stratified charge rotary engine (SCRE) continue to be the subject of active research in recent years. Specifically to meet the demand for more sophisticated products, a detailed understanding of the engine system of interest is warranted. With this in mind the objective of this work is to develop an understanding of the controlling factors that affect the SCRE combustion process so that an efficient power dense rotary engine can be designed. The influence of the induction-exhaust systems and the rotor geometry are believed to have a significant effect on combustion chamber flow characteristics. In this report, emphasis is centered on Laser Doppler Velocimetry (LDV) measurements and on qualitative flow visualizations in the combustion chamber of the motored rotary engine assembly. This will provide a basic understanding of the flow process in the RCE and serve as a data base for verification of numerical simulations. Understanding fuel injection provisions is also important to the successful operation of the stratified charge rotary engine. Toward this end, flow visualizations depicting the development of high speed, high pressure fuel jets are described. Friction is an important consideration in an engine from the standpoint of lost work, durability and reliability. MSU Engine Research Laboratory efforts in accessing the frictional losses associated with the rotary engine are described. This includes work which describes losses in bearing, seal and auxillary components. Finally, a computer controlled mapping system under development is described. This system can be used to map shapes such as combustion chamber, intake manifolds or turbine blades accurately.

  1. Stratified charge rotary engine combustion studies

    NASA Technical Reports Server (NTRS)

    Shock, H.; Hamady, F.; Somerton, C.; Stuecken, T.; Chouinard, E.; Rachal, T.; Kosterman, J.; Lambeth, M.; Olbrich, C.

    1989-01-01

    Analytical and experimental studies of the combustion process in a stratified charge rotary engine (SCRE) continue to be the subject of active research in recent years. Specifically to meet the demand for more sophisticated products, a detailed understanding of the engine system of interest is warranted. With this in mind the objective of this work is to develop an understanding of the controlling factors that affect the SCRE combustion process so that an efficient power dense rotary engine can be designed. The influence of the induction-exhaust systems and the rotor geometry are believed to have a significant effect on combustion chamber flow characteristics. In this report, emphasis is centered on Laser Doppler Velocimetry (LDV) measurements and on qualitative flow visualizations in the combustion chamber of the motored rotary engine assembly. This will provide a basic understanding of the flow process in the RCE and serve as a data base for verification of numerical simulations. Understanding fuel injection provisions is also important to the successful operation of the stratified charge rotary engine. Toward this end, flow visualizations depicting the development of high speed, high pressure fuel jets are described. Friction is an important consideration in an engine from the standpoint of lost work, durability and reliability. MSU Engine Research Laboratory efforts in accessing the frictional losses associated with the rotary engine are described. This includes work which describes losses in bearing, seal and auxillary components. Finally, a computer controlled mapping system under development is described. This system can be used to map shapes such as combustion chamber, intake manifolds or turbine blades accurately.

  2. Failure and fatigue characteristics of adhesive athletic tape.

    PubMed

    Bragg, Richard W; Macmahon, John M; Overom, Erin K; Yerby, Scott A; Matheson, Gordon O; Carter, Dennis R; Andriacchi, Thomas P

    2002-03-01

    Athletic tape has been commonly reported to lose much of its structural support after 20 min of exercise. Although many studies have addressed the functional performance characteristics of athletic tape, its mechanical properties are poorly understood. This study examines the failure and fatigue properties of several commonly used athletic tapes. A Web-based survey of professional sports trainers was used to select the following three tapes for the study: Zonas (Johnson & Johnson), Leukotape (Beiersdorf), and Jaylastic (Jaybird & Mais). Using a hydraulic material testing system (MTS), eight samples of each tape were compared in three different mechanical tests: load-to-failure, fatigue testing under load control, and fatigue testing under displacement control. Differences in tape microstructure were used to interpret the results of the mechanical tests. Significant differences (P < 0.001) in failure load, elongation at failure, and stiffness were found from failure tests. Significant differences were also found (P < 0.001) in fatigue behavior under both modes of control. As a representative example, in one normalized displacement control fatigue test after 20 min of cycling, 21% (Zonas), 29% (Leukotape), and 57% (Jaylastic) of the mechanical support was lost. After cycling, all tapes loaded to failure showed increased stiffness (P < 0.001), indicating significant energy absorption during cycling. Observed differences in the tapes' microstructure were qualitatively consistent with the measured differences in their mechanical properties. In understanding the shortcomings of currently available tapes, the results of these tests can now be used as benchmarks with which to compare and develop future tape designs. Ultimately, these improved tapes should reduce ankle injuries among athletes.

  3. Tape-cast sensors and method of making

    DOEpatents

    Mukundan, Rangachary [Santa Fe, NM; Brosha, Eric L [Los Alamos, NM; Garzon, Fernando H [Santa Fe, NM

    2009-08-18

    A method of making electrochemical sensors in which an electrolyte material is cast into a tape. Prefabricated electrodes are then partially embedded between two wet layers of the electrolyte tape to form a green sensor, and the green sensor is then heated to sinter the electrolyte tape around the electrodes. The resulting sensors can be used in applications such as, but not limited to, combustion control, environmental monitoring, and explosive detection. A electrochemical sensor formed by the tape-casting method is also disclosed.

  4. Wire and Packing Tape Sandwiches

    ERIC Educational Resources Information Center

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  5. Archive Data Tape Library (ADTL)

    DOT National Transportation Integrated Search

    1983-01-01

    The purpose of this directory is to describe the procedures involved in using the ADTL as well as to identify and describe the data tapes contained in the ADTL. This directory provides a listing of the data tapes contained in the ADTL by mode of tran...

  6. Rotary endodontics in primary teeth – A review

    PubMed Central

    George, Sageena; Anandaraj, S.; Issac, Jyoti S.; John, Sheen A.; Harris, Anoop

    2015-01-01

    Endodontic treatment in primary teeth can be challenging and time consuming, especially during canal preparation, which is considered one of the most important steps in root canal therapy. The conventional instrumentation technique for primary teeth remains the “gold-standard” over hand instrumentation, which makes procedures much more time consuming and adversely affects both clinicians and patients. Recently nickel–titanium (Ni–Ti) rotary files have been developed for use in pediatric endodontics. Using rotary instruments for primary tooth pulpectomies is cost effective and results in fills that are consistently uniform and predictable. This article reviews the use of nickel–titanium rotary files as root canal instrumentation in primary teeth. The pulpectomy technique is described here according to different authors and the advantages and disadvantages of using rotary files are discussed. PMID:26792964

  7. 16 CFR 1205.5 - Walk-behind rotary power mower controls.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Walk-behind rotary power mower controls... rotary power mower controls. (a) Blade control systems—(1) Requirements for blade control. A walk-behind rotary power mower shall have a blade control system that will perform the following functions: (i...

  8. Reel-to-reel substrate tape polishing system

    DOEpatents

    Selvamanickam, Venkat; Gardner, Michael T.; Judd, Raymond D.; Weloth, Martin; Qiao, Yunfei

    2005-06-21

    Disclosed is a reel-to-reel single-pass mechanical polishing system (100) suitable for polishing long lengths of metal substrate tape (124) used in the manufacture of high-temperature superconductor (HTS) coated tape, including multiple instantiations of a polishing station (114) in combination with a subsequent rinsing station (116) arranged along the axis of the metal substrate tape (124) that is translating between a payout spool (110a) and a take-up spool (110b). The metal substrate tape obtains a surface smoothness that is suitable for the subsequent deposition of a buffer layer.

  9. Ubiquitous Graphene Electronics on Scotch Tape

    PubMed Central

    Chung, Yoonyoung; Ho Kim, Hyun; Lee, Sangryun; Lee, Eunho; Won Kim, Seong; Ryu, Seunghwa; Cho, Kilwon

    2015-01-01

    We report a novel concept of graphene transistors on Scotch tape for use in ubiquitous electronic systems. Unlike common plastic substrates such as polyimide and polyethylene terephthalate, the Scotch tape substrate is easily attached onto various objects such as banknotes, curved surfaces, and human skin, which implies potential applications wherein electronics can be placed in any desired position. Furthermore, the soft Scotch tape serves as an attractive substrate for flexible/foldable electronics that can be significantly bent, or even crumpled. We found that the adhesive layer of the tape with a relatively low shear modulus relaxes the strain when subjected to bending. The capacitance of the gate dielectric made of oxidized aluminum oxide was 1.5 μF cm−2, so that a supply voltage of only 2.5 V was sufficient to operate the devices. As-fabricated graphene transistors on Scotch tape exhibited high electron mobility of 1326 (±155) cm2 V−1 s−1; the transistors still showed high mobility of 1254 (±478) cm2 V−1 s−1 even after they were crumpled. PMID:26220874

  10. Technique for recovery of voice data from heat damaged magnetic tape

    NASA Technical Reports Server (NTRS)

    Melugin, J. F.; Obrien, D. E., III (Inventor)

    1974-01-01

    A method for conditioning, and thus enabling retrieval of intelligence from, magnetic tapes after damage from heat has caused the tape to wrinkle and curl severely thereby reducing tape width to less than one-half its original size. The damaged tape is superposed on a first piece of splicing tape with the oxide side of the magnetic tape in contact with the adhesive side of the splicing tape and then carefully smoothed by a special tool. A second piece of splicing tape is placed on the backing side of the magnetic tape then the resulting tape stack is trimmed to the original width of the magnetic tape. After the first piece of splicing tape is carefully removed from the oxide side of the damaged magnetic tape, the resulting magnetic tape is then ready to be placed into a recorder for playback.

  11. Paper Tape Prevents Foot Blisters: A Randomized Prevention Trial Assessing Paper Tape in Endurance Distances II (Pre-TAPED II).

    PubMed

    Lipman, Grant S; Sharp, Louis J; Christensen, Mark; Phillips, Caleb; DiTullio, Alexandra; Dalton, Andrew; Ng, Pearlly; Shangkuan, Jennifer; Shea, Katherine; Krabak, Brian J

    2016-09-01

    To determine whether paper tape prevents foot blisters in multistage ultramarathon runners. Multisite prospective randomized trial. The 2014 250-km (155-mile) 6-stage RacingThePlanet ultramarathons in Jordan, Gobi, Madagascar, and Atacama Deserts. One hundred twenty-eight participants were enrolled: 19 (15%) from the Jordan, 35 (27%) from Gobi, 21 (16%) from Madagascar, and 53 (41%) from the Atacama Desert. The mean age was 39.3 years (22-63) and body mass index was 24.2 kg/m (17.4-35.1), with 31 (22.5%) females. Paper tape was applied to a randomly selected foot before the race, either to participants' blister-prone areas or randomly selected location if there was no blister history, with untaped areas of the same foot used as the control. Development of a blister anywhere on the study foot. One hundred six (83%) participants developed 117 blisters, with treatment success in 98 (77%) runners. Paper tape reduced blisters by 40% (P < 0.01, 95% confidence interval, 28-52) with a number needed to treat of 1.31. Most of the study participants had 1 blister (78%), with most common locations on the toes (n = 58, 50%) and heel (n = 27, 23%), with 94 (80%) blisters occurring by the end of stage 2. Treatment success was associated with earlier stages [odds ratio (OR), 74.9, P < 0.01] and time spent running (OR, 0.66, P = 0.01). Paper tape was found to prevent both the incidence and frequency of foot blisters in runners.

  12. The rotary subwoofer: a controllable infrasound source.

    PubMed

    Park, Joseph; Garcés, Milton; Thigpen, Bruce

    2009-04-01

    The rotary subwoofer is a novel acoustic transducer capable of projecting infrasonic signals at high sound pressure levels. The projector produces higher acoustic particle velocities than conventional transducers which translate into higher radiated sound pressure levels. This paper characterizes measured performance of a rotary subwoofer and presents a model to predict sound pressure levels.

  13. Deformation analysis of rotary combustion engine housings

    NASA Technical Reports Server (NTRS)

    Vilmann, Carl

    1991-01-01

    This analysis of the deformation of rotary combustion engine housings targeted the following objectives: (1) the development and verification of a finite element model of the trochoid housing, (2) the prediction of the stress and deformation fields present within the trochoid housing during operating conditions, and (3) the development of a specialized preprocessor which would shorten the time necessary for mesh generation of a trochoid housing's FEM model from roughly one month to approximately two man hours. Executable finite element models were developed for both the Mazda and the Outboard Marine Corporation trochoid housings. It was also demonstrated that a preprocessor which would hasten the generation of finite element models of a rotary engine was possible to develop. The above objectives are treated in detail in the attached appendices. The first deals with finite element modeling of a Wankel engine center housing, and the second with the development of a preprocessor that generates finite element models of rotary combustion engine center housings. A computer program, designed to generate finite element models of user defined rotary combustion engine center housing geometries, is also included.

  14. Shape-Memory Wires Switch Rotary Actuator

    NASA Technical Reports Server (NTRS)

    Brudnicki, Myron J.

    1992-01-01

    Thermomechanical rotary actuator based on shape-memory property of alloy composed of equal parts of titanium and nickel. If alloy stretched while below transition temperature, it reverts to original length when heated above transition temperature. Two capstans on same shaft wrapped with shape-memory wires. As one wire heated, it contracts and stretches opposite wire. Wires heated in alternation so they switch shaft between two extreme angular positions; "on" and "off" positions of rotary valve.

  15. Rotary-Atomizer Electric Power Generator

    NASA Astrophysics Data System (ADS)

    Nguyen, Trieu; Tran, Tuan; de Boer, Hans; van den Berg, Albert; Eijkel, Jan C. T.

    2015-03-01

    We report experimental and theoretical results on a ballistic energy-conversion method based on a rotary atomizer working with a droplet acceleration-deceleration cycle. In a rotary atomizer, liquid is fed onto the center of a rotating flat surface, where it spreads out under the action of the centrifugal force and creates "atomized" droplets at its edge. The advantage of using a rotary atomizer is that the centrifugal force exerted on the fluid on a smooth, large surface is not only a robust form of acceleration, as it avoids clogging, but also easily allows high throughput, and produces high electrical power. We successfully demonstrate an output power of 4.9 mW and a high voltage up to 3120 V. At present, the efficiency of the system is still low (0.14%). However, the conversion mechanism of the system is fully interpreted in this paper, permitting a conceptual understanding of system operation and providing a roadmap for system optimization. This observation will open up a road for building power-generation systems in the near future.

  16. Specification for wide channel bandwidth one-inch video tape

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1988-01-01

    Standards and controls are established for the procurement of wide channel bandwidth one inch video magnetic recording tapes for Very Long Base Interferometer (VLBI) system applications. The Magnetic Tape Certification Facility (MTCF) currently maintains three specifications for the Quality Products List (QPL) and acceptance testing of magnetic tapes. NASA-TM-79724 is used for the QPL and acceptance testing of new analog tapes; NASA-TM-80599 is used for QPL and acceptance testing of new digital tapes; and NASA-TM-100702 is used for the QPL and acceptance testing of new IBM/IBM compatible 3480 magnetic tape cartridges. This specification will be used for the QPL and acceptance testing of new wide channel bandwidth one inch video magnetic recording tapes. The one inch video tapes used by the Jet Propulsion Lab., the Deep Space Network and the Haystack Observatory will be covered by this specification. These NASA stations will use the video tapes for their VLBI system applications. The VLBI system is used for the tracking of quasars and the support of interplanetary exploration.

  17. User's guide and tape specification for ERB 7 DELMAT

    NASA Technical Reports Server (NTRS)

    Ardanuy, P.; Penn, L.

    1985-01-01

    Guidance is provided to the DELMAT user in the areas of purpose, use and limitations of DELMAT tapes and software. The DELMAT tape specifications is also provided. The ERB-7, ERB MAT and tape characteristics applicable to the DELMAT tapes are also summarized.

  18. Note: A novel rotary actuator driven by only one piezoelectric actuator.

    PubMed

    Huang, Hu; Fu, Lu; Zhao, Hongwei; Shi, Chengli; Ren, Luquan; Li, Jianping; Qu, Han

    2013-09-01

    This paper presents a novel piezo-driven rotary actuator based on the parasitic motion principle. Output performances of the rotary actuator were tested and discussed. Experiment results indicate that using only one piezoelectric actuator and simple sawtooth wave control, the rotary actuator reaches the rotation velocity of about 20,097 μrad/s when the driving voltage is 100 V and the driving frequency is 90 Hz. The actuator can rotate stably with the minimum resolution of 0.7 μrad. This paper verifies feasibility of the parasitic motion principle for applications of rotary actuators, providing new design ideas for precision piezoelectric rotary actuators.

  19. Magnetic Tape Recording

    NASA Technical Reports Server (NTRS)

    Athey, Skipwith W.

    1966-01-01

    NASA's contribution to tape recorder technology may appear to lie in such glamorous devices as the tape recorders of the Tiros and Nimbus satellites which receive signals carrying weather information during an orbit around the earth and then transmit those signals back to the ground when the satellite is in view of ground stations. These quite important recording devices are, however, only useful as members of a complex hierarchy of devices all of which participate in the ultimate process of obtaining information from NASA's efforts. Their existence and utility is based on the existence of many more prosaic recording devices which have been involved in the development of such spectacular units.

  20. An improved magnetic tape recorder

    NASA Technical Reports Server (NTRS)

    Uber, P. W.

    1968-01-01

    Magnetic tape recorder employs a single capstan for simultaneously driving the supply and take-up reels in such a manner that the tape passing between the reels is kept under a predetermined constant tension. This recorder operates with little power and is sufficiently rugged to withstand the severe stresses encountered in high-altitude balloon flight tests.

  1. A study of tape adhesive strength on endotracheal tubes.

    PubMed

    Fenje, N; Steward, D J

    1988-03-01

    A method of assessing the adhesive bond of tapes used to secure endotracheal (ET) tubes is described. Five kinds of tape and six different ET tubes including two silicone rubber, wire-reinforced tubes were tested. There are significant differences in the adhesive strength of different tapes, and in the adhesive bond formed by different ET tube materials. On the Portex clear ET tube, silk tape adhered best (p less than 0.001), followed by waterproof, cloth, dermiclear, and micropore tapes. Adhesive bonding by silk tape was significantly greater (p less than 0.001) for the three clear ET tubes (Portex clear, NCC clear, and Portex ivory) than for the Portex blue and the silicone rubber, wire-reinforced ET tubes. All tapes showed very poor or negligible adhesion to the Sheridan and Portex reinforced ET tubes. Adhesion to these tubes was greatly improved by wrapping them tightly with an "op site" dressing prior to applying tape.

  2. A novel processing platform for post tape out flows

    NASA Astrophysics Data System (ADS)

    Vu, Hien T.; Kim, Soohong; Word, James; Cai, Lynn Y.

    2018-03-01

    As the computational requirements for post tape out (PTO) flows increase at the 7nm and below technology nodes, there is a need to increase the scalability of the computational tools in order to reduce the turn-around time (TAT) of the flows. Utilization of design hierarchy has been one proven method to provide sufficient partitioning to enable PTO processing. However, as the data is processed through the PTO flow, its effective hierarchy is reduced. The reduction is necessary to achieve the desired accuracy. Also, the sequential nature of the PTO flow is inherently non-scalable. To address these limitations, we are proposing a quasi-hierarchical solution that combines multiple levels of parallelism to increase the scalability of the entire PTO flow. In this paper, we describe the system and present experimental results demonstrating the runtime reduction through scalable processing with thousands of computational cores.

  3. Rotary head type reproducing apparatus

    DOEpatents

    Takayama, Nobutoshi; Edakubo, Hiroo; Kozuki, Susumu; Takei, Masahiro; Nagasawa, Kenichi

    1986-01-01

    In an apparatus of the kind arranged to reproduce, with a plurality of rotary heads, an information signal from a record bearing medium having many recording tracks which are parallel to each other with the information signal recorded therein and with a plurality of different pilot signals of different frequencies also recorded one by one, one in each of the recording tracks, a plurality of different reference signals of different frequencies are simultaneously generated. A tracking error is detected by using the different reference signals together with the pilot signals which are included in signals reproduced from the plurality of rotary heads.

  4. Tape SCSI monitoring and encryption at CERN

    NASA Astrophysics Data System (ADS)

    Laskaridis, Stefanos; Bahyl, V.; Cano, E.; Leduc, J.; Murray, S.; Cancio, G.; Kruse, D.

    2017-10-01

    CERN currently manages the largest data archive in the HEP domain; over 180PB of custodial data is archived across 7 enterprise tape libraries containing more than 25,000 tapes and using over 100 tape drives. Archival storage at this scale requires a leading edge monitoring infrastructure that acquires live and lifelong metrics from the hardware in order to assess and proactively identify potential drive and media level issues. In addition, protecting the privacy of sensitive archival data is becoming increasingly important and with it the need for a scalable, compute-efficient and cost-effective solution for data encryption. In this paper, we first describe the implementation of acquiring tape medium and drive related metrics reported by the SCSI interface and its integration with our monitoring system. We then address the incorporation of tape drive real-time encryption with dedicated drive hardware into the CASTOR [1] hierarchical mass storage system.

  5. Educational Uses of Cartridge Tapes. Dissemination Document No. 11.

    ERIC Educational Resources Information Center

    Levine, S. Joseph

    Tape cartridges for use by special education teachers are analyzed according to design, effective use, and availability. Basic operating principles of cassette and continuous loop tape cartridges are described and illustrated. Advantages of tape cartridges are indicated, such as the following: the position is saved on tape during student timeouts,…

  6. Methods and systems for fabricating high quality superconducting tapes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Majkic, Goran; Selvamanickam, Venkat

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  7. How Fo-ATPase generates rotary torque.

    PubMed

    Oster, G; Wang, H; Grabe, M

    2000-04-29

    The F-ATPases synthesize ATP using a transmembrane ionmotive force (IMF) established by the electron transport chain. This transduction involves first converting the IMF to a rotary torque in the transmembrane Fo portion. This torque is communicated from Fo to the F1 portion where the energy is used to release the newly synthesized ATP from the catalytic sites according to Boyer's binding change mechanism. Here we explain the principle by which an IMF generates this rotary torque in the Fo ion engine.

  8. Certification of ICI 1012 optical data storage tape

    NASA Technical Reports Server (NTRS)

    Howell, J. M.

    1993-01-01

    ICI has developed a unique and novel method of certifying a Terabyte optical tape. The tape quality is guaranteed as a statistical upper limit on the probability of uncorrectable errors. This is called the Corrected Byte Error Rate or CBER. We developed this probabilistic method because of two reasons why error rate cannot be measured directly. Firstly, written data is indelible, so one cannot employ write/read tests such as used for magnetic tape. Secondly, the anticipated error rates need impractically large samples to measure accurately. For example, a rate of 1E-12 implies only one byte in error per tape. The archivability of ICI 1012 Data Storage Tape in general is well characterized and understood. Nevertheless, customers expect performance guarantees to be supported by test results on individual tapes. In particular, they need assurance that data is retrievable after decades in archive. This paper describes the mathematical basis, measurement apparatus and applicability of the certification method.

  9. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  10. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  11. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 5 2013-10-01 2013-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  12. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  13. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 5 2012-10-01 2012-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  14. Recirculating rotary gas compressor

    DOEpatents

    Weinbrecht, J.F.

    1992-02-25

    A positive displacement, recirculating Roots-type rotary gas compressor is described which operates on the basis of flow work compression. The compressor includes a pair of large diameter recirculation conduits which return compressed discharge gas to the compressor housing, where it is mixed with low pressure inlet gas, thereby minimizing adiabatic heating of the gas. The compressor includes a pair of involutely lobed impellers and an associated port configuration which together result in uninterrupted flow of recirculation gas. The large diameter recirculation conduits equalize gas flow velocities within the compressor and minimize gas flow losses. The compressor is particularly suited to applications requiring sustained operation at higher gas compression ratios than have previously been feasible with rotary pumps, and is particularly applicable to refrigeration or other applications requiring condensation of a vapor. 12 figs.

  15. Adiabatic Wankel type rotary engine

    NASA Technical Reports Server (NTRS)

    Kamo, R.; Badgley, P.; Doup, D.

    1988-01-01

    This SBIR Phase program accomplished the objective of advancing the technology of the Wankel type rotary engine for aircraft applications through the use of adiabatic engine technology. Based on the results of this program, technology is in place to provide a rotor and side and intermediate housings with thermal barrier coatings. A detailed cycle analysis of the NASA 1007R Direct Injection Stratified Charge (DISC) rotary engine was performed which concluded that applying thermal barrier coatings to the rotor should be successful and that it was unlikely that the rotor housing could be successfully run with thermal barrier coatings as the thermal stresses were extensive.

  16. Preliminary design development of 100 KW rotary power transfer device

    NASA Technical Reports Server (NTRS)

    Weinberger, S. M.

    1981-01-01

    Contactless power transfer devices for transferring electrical power across a rotating spacecraft interface were studied. A power level of 100 KW was of primary interest and the study was limited to alternating current devices. Rotary transformers and rotary capacitors together with the required dc to ac power conditioning electronics were examined. Microwave devices were addressed. The rotary transformer with resonant circuit power conditioning was selected as the most feasible approach. The rotary capacitor would be larger while microwave devices would be less efficient. A design analysis was made of a 100 KW, 20 kHz power transfer device consisting of a rotary transformer, power conditioning electronics, drive mechanism and heat rejection system. The size, weight and efficiency of the device were determined. The characteristics of a baseline slip ring were presented. Aspects of testing the 100 KW power transfer device were examined. The power transfer device is a feasible concept which can be implemented using presently available technologies.

  17. DICOM implementation on online tape library storage system

    NASA Astrophysics Data System (ADS)

    Komo, Darmadi; Dai, Hailei L.; Elghammer, David; Levine, Betty A.; Mun, Seong K.

    1998-07-01

    The main purpose of this project is to implement a Digital Image and Communications (DICOM) compliant online tape library system over the Internet. Once finished, the system will be used to store medical exams generated from U.S. ARMY Mobile ARMY Surgical Hospital (MASH) in Tuzla, Bosnia. A modified UC Davis implementation of DICOM storage class is used for this project. DICOM storage class user and provider are implemented as the system's interface to the Internet. The DICOM software provides flexible configuration options such as types of modalities and trusted remote DICOM hosts. Metadata is extracted from each exam and indexed in a relational database for query and retrieve purposes. The medical images are stored inside the Wolfcreek-9360 tape library system from StorageTek Corporation. The tape library system has nearline access to more than 1000 tapes. Each tape has a capacity of 800 megabytes making the total nearline tape access of around 1 terabyte. The tape library uses the Application Storage Manager (ASM) which provides cost-effective file management, storage, archival, and retrieval services. ASM automatically and transparently copies files from expensive magnetic disk to less expensive nearline tape library, and restores the files back when they are needed. The ASM also provides a crash recovery tool, which enable an entire file system restore in a short time. A graphical user interface (GUI) function is used to view the contents of the storage systems. This GUI also allows user to retrieve the stored exams and send the exams to anywhere on the Internet using DICOM protocols. With the integration of different components of the system, we have implemented a high capacity online tape library storage system that is flexible and easy to use. Using tape as an alternative storage media as opposed to the magnetic disk has the great potential of cost savings in terms of dollars per megabyte of storage. As this system matures, the Hospital Information Systems

  18. Equations For Rotary Transformers

    NASA Technical Reports Server (NTRS)

    Salomon, Phil M.; Wiktor, Peter J.; Marchetto, Carl A.

    1988-01-01

    Equations derived for input impedance, input power, and ratio of secondary current to primary current of rotary transformer. Used for quick analysis of transformer designs. Circuit model commonly used in textbooks on theory of ac circuits.

  19. Research on dynamic balancing simulation of rotary shaft based on ADAMS

    NASA Astrophysics Data System (ADS)

    Zheng, Weiqiang; Rui, Chengjie; Yang, Jie; Liu, Pingyi

    2018-02-01

    Due to the design and processing technology of rotary shaft, the mass center of it does not coincide with the rotating axis of the rotary shaft and there is an unbalanced mass. The unbalanced mass can have some disadvantages, such as the centrifugal force, the vibration and so on. Those disadvantages could reduce the accuracy and service life of the equipment.In this paper, the dynamic balance of the rotary shaft is analysed by the theory analysis combined with the dynamic simulation software. This method ensures that the rotary shaft meets the dynamic balancing requirements during the design stage. It effectively supports the structural design of the rotary shift, and provides a way of thinking and method for the design and development of the same type of products.

  20. 21 CFR 886.1905 - Nystagmus tape.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1905 Nystagmus tape. (a) Identification. Nystagmus tape is a device that is a long, narrow strip of fabric or other flexible material on which a series of objects are...

  1. Casting Of Multilayer Ceramic Tapes

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr.

    1991-01-01

    Procedure for casting thin, multilayer ceramic membranes, commonly called tapes, involves centrifugal casting at accelerations of 1,800 to 2,000 times normal gravitational acceleration. Layers of tape cast one at a time on top of any previous layer or layers. Each layer cast from slurry of ground ceramic suspended in mixture of solvents, binders, and other components. Used in capacitors, fuel cells, and electrolytic separation of oxygen from air.

  2. A case for automated tape in clinical imaging.

    PubMed

    Bookman, G; Baune, D

    1998-08-01

    Electronic archiving of radiology images over many years will require many terabytes of storage with a need for rapid retrieval of these images. As more large PACS installations are installed and implemented, a data crisis occurs. The ability to store this large amount of data using the traditional method of optical jukeboxes or online disk alone becomes an unworkable solution. The amount of floor space number of optical jukeboxes, and off-line shelf storage required to store the images becomes unmanageable. With the recent advances in tape and tape drives, the use of tape for long term storage of PACS data has become the preferred alternative. A PACS system consisting of a centrally managed system of RAID disk, software and at the heart of the system, tape, presents a solution that for the first time solves the problems of multi-modality high end PACS, non-DICOM image, electronic medical record and ADT data storage. This paper will examine the installation of the University of Utah, Department of Radiology PACS system and the integration of automated tape archive. The tape archive is also capable of storing data other than traditional PACS data. The implementation of an automated data archive to serve the many other needs of a large hospital will also be discussed. This will include the integration of a filmless cardiology department and the backup/archival needs of a traditional MIS department. The need for high bandwidth to tape with a large RAID cache will be examined and how with an interface to a RIS pre-fetch engine, tape can be a superior solution to optical platters or other archival solutions. The data management software will be discussed in detail. The performance and cost of RAID disk cache and automated tape compared to a solution that includes optical will be examined.

  3. Playback Station #2 for Cal Net and 5-day-recorder tapes

    USGS Publications Warehouse

    Eaton, Jerry P.

    1978-01-01

    A second system (Playback Station #2) has been set up to play back Cal Net 1" tapes and 5-day-recorder 1/2" tapes. As with the first playback system (Playback Station #1) the tapes are played back on a Bell and Howell VR3700B tape deck and the records are written out on a 16-channel direct-writing Siemens "0scillomink." Separate reproduce heads, tape guides, and tape tension sensor rollers are required for playing back 111 tapes and 1/2" tapes, but changing these tape deck components is a simple task that requires only a few minutes. The discriminators, patch panels, selector switches, filters, time code translators, and signal conditioning circuits for the time code translators and for the tape-speed-compensation signal are all mounted in an equipment rack that stands beside the playback tape deck. Changing playback speeds (15/16 ips or 3 3/4 ips) or changing from Cal Net tapes to 5-day-recorder tapes requires only flipping a few switches and/or changing a few patch cables on the patch panel (in addition to changing the reproduce heads, etc., to change from 1" tape to 1/2" tape). For the Cal Net tapes, the system provides for playback of 9 data channels (680 Hz thru 3060 Hz plus 400 Hz) and 3 time signals (IRIG-E, IRIG-C, and WWVB) at both 15/16 ips (x1 speed) and 3 3/4 ips (x4 speed). Available modes of compensation (using either a 4688 Hz reference or a 3125 Hz reference) are subtractive, capstan, capstan plus subtractive, or no compensation.

  4. Restoration of APOLLO Data by the NSSDC and PDS Lunar Data Node

    NASA Technical Reports Server (NTRS)

    Williams, David R.; Hills, H. Kent; Guinness, Edward A.; Taylor, Patrick T.; McBride, Marie J.

    2012-01-01

    The Apollo Lunar Surface Experiment Packages (ALSEPs), suites of instruments deployed by the Apollo 12. 14, 15, 16 and 17 astronauts on the lunar surface, still represent the only in-situ measurements of the Moon's environment taken over long time periods, Much of these data are housed at the National Space Science Data Center (NSSDC) at Goddard Space Flight Center but are in forms that are not readily usable, such as microfilm, hardcopy, and magnetic tapes with older, obsolete formats. The Lunar Data Node (LDN) has been formed under the auspices of the Planetary Data System (PDS) Geosciences Node to put relevant, scientifically important Apollo data into accessible digital form for use by researchers and mission planners. The LDN has prioritized the restoration of these data based on their scientific and engineering value and the level of effort required. We will report on progress made and plans for future data restorations.

  5. Comparison of Broström technique, suture anchor repair, and tape augmentation for reconstruction of the anterior talofibular ligament.

    PubMed

    Schuh, R; Benca, E; Willegger, M; Hirtler, L; Zandieh, S; Holinka, J; Windhager, R

    2016-04-01

    Recently, tape augmentation for Broström repair has been introduced in order to improve the primary stability of the reconstructed anterior talofibular ligament (ATFL). The biomechanical effect of tape augmentation suture anchor (SA) repair is not known yet. The aim of the present study was to compare construct stability of the traditional Broström (TB) repair compared with a stand alone SA repair (SutureTak, Arthrex) and SA repair combined with tape augmentation (InternalBrace, Arthrex) internal brace (IB) of the ATFL. Eighteen fresh-frozen human anatomic lower leg specimens were randomly assigned to three different groups: TB group, SA group, and IB augmentation group. In vivo torsion conditions in ankle sprain were carried out quasi-statically (0.5°/s). Torque (Nm) required to resist as well as the rotary displacement (°) of the load frame was recorded. Intergroup differences for age, bone mineral density (BMD), angle at failure, and torque at failure were analysed using ANOVA. In the TB group, ATFL reconstruction failed at an angle of 24.1°, in the SA group failure occurred at 35.5°, and in the IB group it failed at 46.9° (p = 0.02). Torque at failure reached 5.7 Nm for the TB repair, 8.0 Nm for the SA repair, and 11.2 Nm for the IB group (p = 0.04). There was no correlation between angle at ATFL failure, torque at failure, and BMD for the SA or IB groups. The present biomechanical study reveals statistically superior performance in terms of angle at failure as well as failure torque for the IB group compared to the other reconstruction methods. BMD did not influence the construct stability in the SA repair groups.

  6. Systematic Review of the Effect of Taping Techniques on Patellofemoral Pain Syndrome.

    PubMed

    Logan, Catherine A; Bhashyam, Abhiram R; Tisosky, Ashley J; Haber, Daniel B; Jorgensen, Anna; Roy, Adam; Provencher, Matthew T

    Taping is commonly used in the management of several musculoskeletal conditions, including patellofemoral pain syndrome (PFPS). Specific guidelines for taping are unknown. To investigate the efficacy of knee taping in the management of PFPS. Our hypothesis was that tension taping and exercise would be superior to placebo taping and exercise as well as to exercise or taping alone. The PubMed/MEDLINE, Cochrane, Rehabilitation and Sports Medicine Source, and CINAHL databases were reviewed for English-language randomized controlled trials (RCTs) evaluating the efficacy of various taping techniques that were published between 1995 and April 2015. Keywords utilized included taping, McConnell, kinesio-taping, kinesiotaping, patellofemoral pain, and knee. Studies included consisted of RCTs (level 1 or 2) with participants of all ages who had anterior knee or patellofemoral pain symptoms and had received nonsurgical management using any taping technique. Systematic review. Level 2. A checklist method was used to determine selection, performance, detection, and attrition bias for each article. A quality of evidence grading was then referenced using the validated PEDro database for RCTs. Three difference comparison groups were compared: tension taping and exercise versus placebo taping and exercise (group 1), placebo taping and exercise versus exercise alone (group 2), and tension taping and exercise versus taping alone (group 3). Five RCTs with 235 total patients with multiple intervention arms were included. Taping strategies included McConnell and Kinesiotaping. Visual analog scale (VAS) scores indicated improvement in all 3 comparison groups (group 1: 91 patients, 39% of total, mean VAS improvement 44.9 [tension taping + exercise] vs 66 [placebo taping + exercise]; group 2: 56 patients, 24% of total, mean VAS improvement 66 [placebo taping + exercise] vs 47.6 [exercise alone]; and group 3: 112 patients, 48% of total, mean VAS improvement 44.9 [tension taping + exercise

  7. Recirculating rotary gas compressor

    DOEpatents

    Weinbrecht, John F.

    1992-01-01

    A positive displacement, recirculating Roots-type rotary gas compressor which operates on the basis of flow work compression. The compressor includes a pair of large diameter recirculation conduits (24 and 26) which return compressed discharge gas to the compressor housing (14), where it is mixed with low pressure inlet gas, thereby minimizing adiabatic heating of the gas. The compressor includes a pair of involutely lobed impellers (10 and 12) and an associated port configuration which together result in uninterrupted flow of recirculation gas. The large diameter recirculation conduits equalize gas flow velocities within the compressor and minimize gas flow losses. The compressor is particularly suited to applications requiring sustained operation at higher gas compression ratios than have previously been feasible with rotary pumps, and is particularly applicable to refrigeration or other applications requiring condensation of a vapor.

  8. Aligned Carbon Nanotube Tape for Sensor Applications

    NASA Technical Reports Server (NTRS)

    Tucker, Dennis S.

    2013-01-01

    For this effort, will concentrate on three applications: Vibration Gyroscope utilizes piezoelectric properties of the tape and Coriolis effect Accelerometer utilizes the piezoresistive property Strain Gauge utilizes piezoresistive property Accelerometer and Strain Gauge can also utilize piezoelectric effect Test piezoelectric properties using facilities at the Microfabrication Laboratory (AMRDEC) . Enhance piezoelectric effect using polyvinylidine fluoride and P(VDF ]TrFE) which is readily polarizable .Spray matrix solution while winding fiber; Sandwich of CNT tape and PVDF film (DOE .Two Level) . Construct and test prototype vibration gyroscope . Construct and test prototype accelerometer using cantilever design . Test strain sensitivity of CNT tape against industrial strain gauge . Embed CNT tape in composite samples as well as on surface and test to failure (4 ]point bend) A piezoelectric device exhibits an electrical response from a mechanical applied stress. . A piezoelectric device has both capacitance and resistance properties in which by applying an electric field from a waveform will exert a mechanical stress that can be monitored for a response. . The typical waveform applied is a sinusoidal waveform of a defined voltage for a defined period. The defined voltage is driven from 0 volts to the positive defined volts then back to 0 and driven to negative defined volts then back to 0. . Example. Vmax set to 10V and period set to 10 ms. . Voltage will start at zero, go to 10 volts, return to zero, go to ]10 volts and return to zero during 10 ms. . Applying this electrical field to a DUT, the capacitance response and resistance response can be observed. CNT tape is easier to manufacture and cheaper than micromachining silicon or other ceramic piezoelectric used in gyroscopes and accelerometers CNT tape properties can be modified during manufacture for specific application CNT tape has enhanced mechanical and thermal properties in addition to unique electrical

  9. Energy efficient cooperation in underlay RFID cognitive networks for a water smart home.

    PubMed

    Nasir, Adnan; Hussain, Syed Imtiaz; Soong, Boon-Hee; Qaraqe, Khalid

    2014-09-30

    Shrinking water resources all over the world and increasing costs of water consumption have prompted water users and distribution companies to come up with water conserving strategies. We have proposed an energy-efficient smart water monitoring application in [1], using low power RFIDs. In the home environment, there exist many primary interferences within a room, such as cell-phones, Bluetooth devices, TV signals, cordless phones and WiFi devices. In order to reduce the interference from our proposed RFID network for these primary devices, we have proposed a cooperating underlay RFID cognitive network for our smart application on water. These underlay RFIDs should strictly adhere to the interference thresholds to work in parallel with the primary wireless devices [2]. This work is an extension of our previous ventures proposed in [2,3], and we enhanced the previous efforts by introducing a new system model and RFIDs. Our proposed scheme is mutually energy efficient and maximizes the signal-to-noise ratio (SNR) for the RFID link, while keeping the interference levels for the primary network below a certain threshold. A closed form expression for the probability density function (pdf) of the SNR at the destination reader/writer and outage probability are derived. Analytical results are verified through simulations. It is also shown that in comparison to non-cognitive selective cooperation, this scheme performs better in the low SNR region for cognitive networks. Moreover, the hidden Markov model's (HMM) multi-level variant hierarchical hidden Markov model (HHMM) approach is used for pattern recognition and event detection for the data received for this system [4]. Using this model, a feedback and decision algorithm is also developed. This approach has been applied to simulated water pressure data from RFID motes, which were embedded in metallic water pipes.

  10. Energy Efficient Cooperation in Underlay RFID Cognitive Networks for a Water Smart Home

    PubMed Central

    Nasir, Adnan; Hussain, Syed Imtiaz; Soong, Boon-Hee; Qaraqe, Khalid

    2014-01-01

    Shrinking water resources all over the world and increasing costs of water consumption have prompted water users and distribution companies to come up with water conserving strategies. We have proposed an energy-efficient smart water monitoring application in [1], using low power RFIDs. In the home environment, there exist many primary interferences within a room, such as cell-phones, Bluetooth devices, TV signals, cordless phones and WiFi devices. In order to reduce the interference from our proposed RFID network for these primary devices, we have proposed a cooperating underlay RFID cognitive network for our smart application on water. These underlay RFIDs should strictly adhere to the interference thresholds to work in parallel with the primary wireless devices [2]. This work is an extension of our previous ventures proposed in [2,3], and we enhanced the previous efforts by introducing a new system model and RFIDs. Our proposed scheme is mutually energy efficient and maximizes the signal-to-noise ratio (SNR) for the RFID link, while keeping the interference levels for the primary network below a certain threshold. A closed form expression for the probability density function (pdf) of the SNR at the destination reader/writer and outage probability are derived. Analytical results are verified through simulations. It is also shown that in comparison to non-cognitive selective cooperation, this scheme performs better in the low SNR region for cognitive networks. Moreover, the hidden Markov model’s (HMM) multi-level variant hierarchical hidden Markov model (HHMM) approach is used for pattern recognition and event detection for the data received for this system [4]. Using this model, a feedback and decision algorithm is also developed. This approach has been applied to simulated water pressure data from RFID motes, which were embedded in metallic water pipes. PMID:25271565

  11. TMR tape drive for a 15 TB cartridge

    NASA Astrophysics Data System (ADS)

    Biskeborn, Robert G.; Fontana, Robert E.; Lo, Calvin S.; Czarnecki, W. Stanley; Liang, Jason; Iben, Icko E. T.; Decad, Gary M.; Hipolito, Venus A.

    2018-05-01

    This paper highlights the development of tunnel magnetoresistive (TMR) sensors for magnetic tape recording applications. This has led to the introduction of a tape drives supporting a 15 TB native tape cartridge, currently the highest capacity available. Underscoring this development is the fact that the TMR sensors must run in continual contact with the tape media. This is contrasted with modern hard disk drive (hdd) sensors, which fly above the disk platters. Various challenges encountered in developing and deploying TMR are presented. In addition, advances to the write transducer are also discussed. Lastly, the authors show that future density scaling for tape recording, unlike that for hdd, is not facing limits imposed by photolithography or superparamagnetic physics, suggesting that cartridge capacity improvements of 4 to 6x will be achieved in the next 4 to 8 years.

  12. Rotary pneumatic valve

    DOEpatents

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  13. Survey of Scientific-Technical Tape Services.

    ERIC Educational Resources Information Center

    Carroll, Kenneth D., Ed.

    The results of a survey of commercially available tape services which can provide libraries and information centers with data bases of scientific and technical literature are reported. During the past few years there has been an increasing number of tape services entering the information resources market. Each of these services makes available to…

  14. Multiple Generations on Video Tape Recorders.

    ERIC Educational Resources Information Center

    Wiens, Jacob H.

    Helical scan video tape recorders were tested for their dubbing characteristics in order to make selection data available to media personnel. The equipment, two recorders of each type tested, was submitted by the manufacturers. The test was designed to produce quality evaluations for three generations of a single tape, thereby encompassing all…

  15. Editing of EIA coded, numerically controlled, machine tool tapes

    NASA Technical Reports Server (NTRS)

    Weiner, J. M.

    1975-01-01

    Editing of numerically controlled (N/C) machine tool tapes (8-level paper tape) using an interactive graphic display processor is described. A rapid technique required for correcting production errors in N/C tapes was developed using the interactive text editor on the IMLAC PDS-ID graphic display system and two special programs resident on disk. The correction technique and special programs for processing N/C tapes coded to EIA specifications are discussed.

  16. High Pressure Rotary Shaft Sealing Mechanism

    DOEpatents

    Dietle, Lannie; Gobeli, Jeffrey D.

    2001-05-08

    A laterally translatable pressure staged rotary shaft sealing mechanism having a seal housing with a shaft passage therein being exposed to a fluid pressure P1 and with a rotary shaft being located within the shaft passage. At least one annular laterally translatable seal carrier is provided. First and second annular resilient sealing elements are supported in axially spaced relation by the annular seal carriers and have sealing relation with the rotary shaft. The seal housing and at least one seal carrier define a first pressure staging chamber exposed to the first annular resilient sealing element and a second pressure staging chamber located between and exposed to the first and second annular resilient sealing elements. A first fluid is circulated to the first pressure chamber at a pressure P1, and a second staging pressure fluid is circulated to the second pressure chamber at a fraction of pressure P1 to achieve pressure staging, cooling of the seals. Seal placement provides hydraulic force balancing of the annular seal carriers.

  17. Improving the Spacelab mass memory unit tape layout with a simulation model

    NASA Technical Reports Server (NTRS)

    Noneman, S. R.

    1984-01-01

    A tape drive called the Mass Memory Unit (MMU) stores software used by Spacelab computers. MMU tape motion must be minimized during typical flight operations to avoid a loss of scientific data. A projection of the tape motion is needed for evaluation of candidate tape layouts. A computer simulation of the scheduled and unscheduled MMU tape accesses is developed for this purpose. This simulation permits evaluations of candidate tape layouts by tracking and summarizing tape movements. The factors that affect tape travel are investigated and a heuristic is developed to find a good tape layout. An improved tape layout for Spacelab I is selected after the evaluation of fourteen candidates. The simulation model will provide the ability to determine MMU layouts that substantially decrease the tape travel on future Spacelab flights.

  18. Getting in Taped, Part I and Part II

    ERIC Educational Resources Information Center

    Cundy, H. M.; Higgins, J.

    1971-01-01

    This article is in two parts: discussion of mathematical concepts involved in converting the reading from the tape-recorder counter which counts the turns of the run-off spool to that from the counter which counts turns of the take-up spool; calculating the length of tape run off when given the reading from the tape-recorder counter of the run-off…

  19. 25. INTERIOR OF ROTARY CAR DUMPER BUILDING WITH VIEW OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    25. INTERIOR OF ROTARY CAR DUMPER BUILDING WITH VIEW OF ROTARY CAR DUMPER LOOKING NORTHEAST. (Jet Lowe) - U.S. Steel Duquesne Works, Blast Furnace Plant, Along Monongahela River, Duquesne, Allegheny County, PA

  20. Root-canal shaping with manual and rotary Ni-Ti files performed by students.

    PubMed

    Sonntag, D; Delschen, S; Stachniss, V

    2003-11-01

    To investigate root-canal shaping with manual and rotary Ni-Ti files performed by students. Thirty undergraduate dental students prepared 150 simulated curved root canals in resin blocks with manual Ni-Ti files with a stepback technique and 450 simulated curved canals with rotary Ni-Ti files with a crowndown technique. Incidence of fracture, preparation length, canal shape and preparation time were investigated. Questionnaires were then issued to the students for them to note their experience of the two preparation methods. Zips and elbows occurred significantly (P < 0.001) less frequently with rotary than with manual preparation. The correct preparation length was achieved significantly (P < 0.05) more often with rotary files than with manual files. Instrument fractures were recorded in only 1.3% of cases with both rotary and manual preparation. The mean time required for manual preparation was significantly (P < 0.001) longer than that required for rotary preparation. Prior experience with a hand preparation technique was not reflected in an improved quality of the subsequent rotary preparation. Approximately 83% of the students claimed to have a greater sense of security in rotary than in manual preparation. Overall 50% felt that manual and engine-driven preparation should be given equal status in undergraduate dental education. Inexperienced operators achieved better canal preparations with rotary instruments than with manual files. No difference in fracture rate was recorded between the two systems.

  1. Magnetic tape

    NASA Technical Reports Server (NTRS)

    Robinson, Harriss

    1992-01-01

    The move to visualization and image processing in data systems is increasing the demand for larger and faster mass storage systems. The technology of choice is magnetic tape. This paper briefly reviews the technology past, present, and projected. A case is made for standards and the value of the standards to users.

  2. Calibration tests on magnetic tape lightning current detectors

    NASA Technical Reports Server (NTRS)

    Crouch, K. E.

    1980-01-01

    The low cost, passive, peak lightning current detector (LCD) invented at the NASA/Kennedy Space Center, uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. Test results show that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10% were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. The stopwatch technique is a simple, low cost means of obtaining LCD readouts and can be used in the field to obtain immediate results. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result. If the shape of the conductor is other than circular (i.e., angle, channel, H-beam), an analysis of the magnetic field is required to use an LCD, especially at low current levels.

  3. Development of a rotary power transformer and inverter drive for spacecraft

    NASA Technical Reports Server (NTRS)

    Mclyman, W. T.; Bridgeforth, A. O.

    1983-01-01

    Many future satellites and spacecraft with spun and despun configurations will require the transfer of power across rotating interfaces in lieu of slip-rings and/or flexures. This is particularly true of spacecraft that have to demonstrate a long life expectancy. The rotary transformer has the desirable characteristics of high reliability and low noise, which qualify it as a potential replacement for slip rings. Development of a rotary power transformer follows the successful completion of a task to develop rotary signal-level transformers for the Galileo Spacecraft Project. The physical configuration of a rotary power transformer has a significant effect on its magnetic and electrical characteristics and therefore impacts the design of the dc/ac inverter driver. Important characteristics addressed during this development effort include: operating frequency, efficiency, transformer gap size, leakage inductance, and leakage flux. A breadboard inverter and rotary transformer were designed, fabricated and tested.

  4. Analysis of Apex Seal Friction Power Loss in Rotary Engines

    NASA Technical Reports Server (NTRS)

    Handschuh, Robert F.; Owen, A. Karl

    2010-01-01

    An analysis of the frictional losses from the apex seals in a rotary engine was developed. The modeling was initiated with a kinematic analysis of the rotary engine. Next a modern internal combustion engine analysis code was altered for use in a rotary engine to allow the calculation of the internal combustion pressure as a function of rotor rotation. Finally the forces from the spring, inertial, and combustion pressure on the seal were combined to provide the frictional horsepower assessment.

  5. Accuracy testing of electric groundwater-level measurement tapes

    USGS Publications Warehouse

    Jelinski, Jim; Clayton, Christopher S.; Fulford, Janice M.

    2015-01-01

    The accuracy tests demonstrated that none of the electric-tape models tested consistently met the suggested USGS accuracy of ±0.01 ft. The test data show that the tape models in the study should give a water-level measurement that is accurate to roughly ±0.05 ft per 100 ft without additional calibration. To meet USGS accuracy guidelines, the electric-tape models tested will need to be individually calibrated. Specific conductance also plays a part in tape accuracy. The probes will not work in water with specific conductance values near zero, and the accuracy of one probe was unreliable in very high conductivity water (10,000 microsiemens per centimeter).

  6. Catalysis-Enhancement via Rotary Fluctuation of F1-ATPase

    PubMed Central

    Watanabe, Rikiya; Hayashi, Kumiko; Ueno, Hiroshi; Noji, Hiroyuki

    2013-01-01

    Protein conformational fluctuations modulate the catalytic powers of enzymes. The frequency of conformational fluctuations may modulate the catalytic rate at individual reaction steps. In this study, we modulated the rotary fluctuation frequency of F1-ATPase (F1) by attaching probes with different viscous drag coefficients at the rotary shaft of F1. Individual rotation pauses of F1 between rotary steps correspond to the waiting state of a certain elementary reaction step of ATP hydrolysis. This allows us to investigate the impact of the frequency modulation of the rotary fluctuation on the rate of the individual reaction steps by measuring the duration of rotation pauses. Although phosphate release was significantly decelerated, the ATP-binding and hydrolysis steps were less sensitive or insensitive to the viscous drag coefficient of the probe. Brownian dynamics simulation based on a model similar to the Sumi-Marcus theory reproduced the experimental results, providing a theoretical framework for the role of rotational fluctuation in F1 rate enhancement. PMID:24268150

  7. Multiple resonance peaks of FeCo thin films with NiFe underlayer

    NASA Astrophysics Data System (ADS)

    Zhong, Xiaoxi; Soh, Wee Tee; Phuoc, Nguyen N.; Liu, Ying; Ong, C. K.

    2015-01-01

    Under zero external magnetic fields, single-layer FeCo thin films exhibit no ferromagnetic resonance (FMR) peaks, while multiple FMR peaks were obtained by growing FeCo thin films on NiFe underlayers with various thicknesses up to 50 nm. Comprehensive investigations of the dynamic magnetic properties and origin of the peaks were conducted through measurements of microwave permeability via a shorted microstrip perturbation technique. Through fitted values of saturation magnetization Ms, uniaxial anisotropy HKsta, and rotatable anisotropy HKrot extracted from the FMR experiments, it was found that two of the three resonance peaks originate from FeCo, and the third from NiFe. The two magnetic phases of FeCo grains are found to have different values of HKrot and explained by the exchange interaction between FeCo and NiFe grains.

  8. Fabrication of Polyimide-Matrix/Carbon and Boron-Fiber Tape

    NASA Technical Reports Server (NTRS)

    Belvin, Harry L.; Cano, Roberto J.; Treasure, Monte; Shahood, Thomas W.

    2007-01-01

    The term HYCARB denotes a hybrid composite of polyimide matrices reinforced with carbon and boron fibers. HYCARB and an improved process for fabricating dry HYCARB tapes have been invented in a continuing effort to develop lightweight, strong composite materials for aerospace vehicles. Like other composite tapes in this line of development, HYCARB tapes are intended to be used to build up laminated structures having possibly complex shapes by means of automated tow placement (ATP) - a process in which a computer-controlled multiaxis machine lays down prepreg tape or tows. The special significance of the present process for making dry HYCARB for ATP is that it contributes to the reduction of the overall cost of manufacturing boron-reinforced composite-material structures while making it possible to realize increased compression strengths. The present process for making HYCARB tapes incorporates a "wet to dry" process developed previously at Langley Research Center. In the "wet to dry" process, a flattened bundle of carbon fiber tows, pulled along a continuous production line between pairs of rollers, is impregnated with a solution of a poly(amide acid) in N-methyl-2-pyrrolidinone (NMP), then most of the NMP is removed by evaporation in hot air. In the present case, the polyamide acid is, more specifically, that of LaRC. IAX (or equivalent) thermoplastic polyimide, and the fibers are, more specifically, Manganite IM7 (or equivalent) polyacrylonitrile- based carbon filaments that have a diameter of 5.2 m and are supplied in 12,000-filament tows. The present process stands in contrast to a prior process in which HYCARB tape was made by pressing boron fibers into the face of a wet carbon-fiber/ poly(amide acid) prepreg tape . that is, a prepreg tape from which the NMP solvent had not been removed. In the present process, one or more layer(s) of side-by-side boron fibers are pressed between dry prepreg tapes that have been prepared by the aforementioned gwet to dry h

  9. Rotary-To-Axial Motion Converter For Valve

    NASA Technical Reports Server (NTRS)

    Reinicke, Robert H.; Mohtar, Rafic

    1991-01-01

    Nearly frictionless mechanism converts rotary motion into axial motion. Designed for use in electronically variable pressure-regulator valve. Changes rotary motion imparted by motor into translation that opens and closes valve poppet. Cables spaced equidistantly around edge of fixed disk support movable disk. As movable disk rotated, cables twist, lifting it. When rotated in opposite direction, cables untwist, lowering it. Spider disk helps to prevent cables from tangling. Requires no lubrication and insensitive to contamination in fluid flowing through valve.

  10. GSFC specification electronic data processing magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Tinari, D. F.; Perry, J. L.

    1980-01-01

    The design requirements are given for magnetic oxide coated, electronic data processing tape, wound on reels. Magnetic recording tape types covered by this specification are intended for use on digital tape transports using the Non-Return-to-Zero-change-on-ones (NRZI) recording method for recording densities up to and including 800 characters per inch (cpi) and the Phase-Encoding (PE) recording method for a recording density of 1600 cpi.

  11. Portable digital pressure indicator for calibrating magnetic tape recorders

    NASA Technical Reports Server (NTRS)

    Mccormick, Royce F.; Leighty, Bradley D.

    1989-01-01

    The design of a portable Digital Pressure Indicator (DPI) to be used for calibrating the pressure systems on Langley's magnetic tape recorders is described. High-speed magnetic tape recorders require pressure (0 to 20 psig) for providing an air cushion across the tape guides and a slight vacuum (30 inch H2O) for maintaining the proper number of tape loops in the advance and feed chamber. The DPI is a hand-held device that can be quickly coupled to a magnetic tape recorder and includes a two-position switch for selecting either measured pressure or vacuum, to be displayed digitally in engineering units (psig or inches H2O). The DPI is currently in use in Langley's Analysis and Computation Division.

  12. OCLC-MARC Tape Processing: A Functional Analysis.

    ERIC Educational Resources Information Center

    Miller, Bruce Cummings

    1984-01-01

    Analyzes structure of, and data in, the OCLC-MARC record in the form delivered via OCLC's Tape Subscription Service, and outlines important processing functions involved: "unreadable tapes," duplicate records and deduping, match processing, choice processing, locations processing, "automatic" and "input" stamps,…

  13. The dynamic stator stalk of rotary ATPases

    PubMed Central

    Stewart, Alastair G.; Lee, Lawrence K.; Donohoe, Mhairi; Chaston, Jessica J.; Stock, Daniela

    2012-01-01

    Rotary ATPases couple ATP hydrolysis/synthesis with proton translocation across biological membranes and so are central components of the biological energy conversion machinery. Their peripheral stalks are essential components that counteract torque generated by rotation of the central stalk during ATP synthesis or hydrolysis. Here we present a 2.25-Å resolution crystal structure of the peripheral stalk from Thermus thermophilus A-type ATPase/synthase. We identify bending and twisting motions inherent within the structure that accommodate and complement a radial wobbling of the ATPase headgroup as it progresses through its catalytic cycles, while still retaining azimuthal stiffness necessary to counteract rotation of the central stalk. The conformational freedom of the peripheral stalk is dictated by its unusual right-handed coiled-coil architecture, which is in principle conserved across all rotary ATPases. In context of the intact enzyme, the dynamics of the peripheral stalks provides a potential mechanism for cooperativity between distant parts of rotary ATPases. PMID:22353718

  14. Corticotomy-facilitated orthodontics using piezosurgery versus rotary instruments: an experimental study.

    PubMed

    Farid, Karim A; Mostafa, Yehya A; Kaddah, Mohammed A; El-Sharaby, Fouad Aly

    2014-10-01

    The aim of this study was to evaluate corticotomy-facilitated orthodontics (CFO) using piezosurgery versus conventional rotary instruments. Ten healthy adult male mongrel dogs of comparable age with a complete set of permanent dentition with average weights between 13-17 kilograms were used. CFO using conventional rotary instruments versus piezosurgery was performed on each dog in a split mouth design. For every dog, mandibular 2nd premolar retraction on each side was attempted after extracting 3rd premolars followed by corticotomy-facilitated orthodontics using conventional rotary surgical burs on the left side and an ultrasonic piezosurgery system on the right side of the same animal. Intraoral measurements of the rate of tooth movement were taken with a sliding caliper. Measurements were performed by the same operator at the time of surgery (appliance delivery) and every month for six months. The dogs were sacrificed after six months from initiation of tooth movement to evaluate the amount of tooth movement for both conventional rotary and piezosurgery corticotomy techniques. A statistically significantly higher mean amount of tooth movement for conventional rotary instrument versus the piezosurgery corticotomy technique was observed at all time intervals. Tooth movement was 1.6 times faster when CFO was done using conventional rotary instruments as compared to a piezosurgery device.

  15. Floating Node Method and Virtual Crack Closure Technique for Modeling Matrix Cracking-Delamination Interaction

    NASA Technical Reports Server (NTRS)

    DeCarvalho, N. V.; Chen, B. Y.; Pinho, S. T.; Baiz, P. M.; Ratcliffe, J. G.; Tay, T. E.

    2013-01-01

    A novel approach is proposed for high-fidelity modeling of progressive damage and failure in composite materials that combines the Floating Node Method (FNM) and the Virtual Crack Closure Technique (VCCT) to represent multiple interacting failure mechanisms in a mesh-independent fashion. In this study, the approach is applied to the modeling of delamination migration in cross-ply tape laminates. Delamination, matrix cracking, and migration are all modeled using fracture mechanics based failure and migration criteria. The methodology proposed shows very good qualitative and quantitative agreement with experiments.

  16. Floating Node Method and Virtual Crack Closure Technique for Modeling Matrix Cracking-Delamination Migration

    NASA Technical Reports Server (NTRS)

    DeCarvalho, Nelson V.; Chen, B. Y.; Pinho, Silvestre T.; Baiz, P. M.; Ratcliffe, James G.; Tay, T. E.

    2013-01-01

    A novel approach is proposed for high-fidelity modeling of progressive damage and failure in composite materials that combines the Floating Node Method (FNM) and the Virtual Crack Closure Technique (VCCT) to represent multiple interacting failure mechanisms in a mesh-independent fashion. In this study, the approach is applied to the modeling of delamination migration in cross-ply tape laminates. Delamination, matrix cracking, and migration are all modeled using fracture mechanics based failure and migration criteria. The methodology proposed shows very good qualitative and quantitative agreement with experiments.

  17. Kinesio Taping Fundamentals for the Equine Athlete.

    PubMed

    Molle, Sybille

    2016-04-01

    The Kinesio taping method was developed in Japan for use in humans in 1979. The use of complementary therapies is becoming common in equine athletes and the discovery of Kinesio taping potential brought it into the animal world. Kinesio taping can be used to treat a wide range of clinical conditions, from tendon injuries to neurologic disorders and from muscle contractures to postural insufficiencies. Its use in veterinary medicine is promising, but relies heavily on evidence-based clinical reports. Further scientific research is needed to fully understand the real effectiveness of application. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. In vitro assessment of cutting efficiency and durability of zirconia removal diamond rotary instruments.

    PubMed

    Kim, Joon-Soo; Bae, Ji-Hyeon; Yun, Mi-Jung; Huh, Jung-Bo

    2017-06-01

    Recently, zirconia removal diamond rotary instruments have become commercially available for efficient cutting of zirconia. However, research of cutting efficiency and the cutting characteristics of zirconia removal diamond rotary instruments is limited. The purpose of this in vitro study was to assess and compare the cutting efficiency, durability, and diamond rotary instrument wear pattern of zirconia diamond removal rotary instruments with those of conventional diamond rotary instruments. In addition, the surface characteristics of the cut zirconia were assessed. Block specimens of 3 mol% yttrium cation-doped tetragonal zirconia polycrystal were machined 10 times for 1 minute each using a high-speed handpiece with 6 types of diamond rotary instrument from 2 manufacturers at a constant force of 2 N (n=5). An electronic scale was used to measure the lost weight after each cut in order to evaluate the cutting efficiency. Field emission scanning electron microscopy was used to evaluate diamond rotary instrument wear patterns and machined zirconia block surface characteristics. Data were statistically analyzed using the Kruskal-Wallis test, followed by the Mann-Whitney U test (α=.05). Zirconia removal fine grit diamond rotary instruments showed cutting efficiency that was reduced compared with conventional fine grit diamond rotary instruments. Diamond grit fracture was the most dominant diamond rotary instrument wear pattern in all groups. All machined zirconia surfaces were primarily subjected to plastic deformation, which is evidence of ductile cutting. Zirconia blocks machined with zirconia removal fine grit diamond rotary instruments showed the least incidence of surface flaws. Although zirconia removal diamond rotary instruments did not show improved cutting efficiency compared with conventional diamond rotary instruments, the machined zirconia surface showed smoother furrows of plastic deformation and fewer surface flaws. Copyright © 2016 Editorial Council

  19. A Short Study of Large Rotary Forged Cylinders

    DTIC Science & Technology

    1979-06-01

    ESR Steel Hollow ESR Steel Rotary Forge Vacuum Degassed Steel 20. ABSTRACT (Continue on reverse aide It necessary and identity by block number...treatment rging Line was used to produce steel for the Advanced ocram. Cylinders were rotary forged from cast hollow ESR ssed steel . Anomalies in the data...prompted a more detailed The results are presented. Satisfactory properties were cuum degassed steel . However, the very light forging th the very

  20. Rotary responds to women's health needs.

    PubMed

    Devlyn, F J

    2000-07-01

    In working to improve the health of women, particularly in developing countries, governments face a monumental challenge. Limited resources, insufficient training, and poor infrastructure are just some of the obstacles to advancements in the field of female medicine. It is a goal of Rotary International, a worldwide association of service-minded business and professional people, to facilitate efforts to bring medical care to women and girls and to help them to build all-around healthy lives. This article gives background on Rotary International and highlights some of the ways Rotarians are using their resources, their global network, and their professional expertise to advance and promote women's health.

  1. Forensic utility of the carbon isotope ratio of PVC tape backings

    NASA Astrophysics Data System (ADS)

    Stern, L. A.; Thompson, A. H.; Mehltretter, A. H.; McLaskey, V.; Parish, A.; Aranda, R.

    2008-12-01

    Forensic interest in adhesive tapes with PVC-backings (polyvinyl chloride, electrical tapes) derives from their use in construction of improvised explosive devices, drug packaging and in a variety of other illicit activities. Due to the range of physical characteristics and chemical compositions of such tapes, traditional microscopic and chemical analysis of the tape backings and adhesives offer a high degree of discrimination between tapes from different manufacturers and products. To evaluate whether carbon isotope ratios may be able to increase discrimination of electrical tapes, particularly with regards to different tapes of the same product, we assessed the PVC-backings of 87 rolls of black electrical tape for their δ13C values. The adhesive on these tapes was physically removed with hexane, and plasticizers within the PVC tape backings were removed by three-20 minute extractions with chloroform. The δ13C values of the PVC tape backings ranged between -23.8 and -41.5 (‰ V-PDB). The carbon isotopic variation within a product (identical brand and product identification) is significant, based on five products with at least 3 rolls (ranges of 7.4‰ (n=3), 10.0‰ (n=6), 4.2‰ (n=16), 3.8‰ (n=6), and 11.5‰ (n=8), respectively). There was no measurable carbon isotope variation in regards to the following: a) along the length of a roll (4 samples from 1 roll); b) between the center and edge of a strip of tape (1 pair); c) between rolls assumed to be from the same lot of tape (2 pairs); d) between different rolls from the same batch of tape (same product purchased at the same time and place; 5 pairs); and e) between samples of a tape at room temperature, heated to 50° C and 80° C for 1 week. For each sample within the population of 87 tapes, carbon isotopes alone exclude 80 to 100% of the tapes as a potential match, with an average exclusion power of 92.5%, using a window of ± 0.4‰. Carbon isotope variations originate from variations in starting

  2. Method and apparatus for depositing a coating on a tape carrier

    DOEpatents

    Storer, Jonathan; Matias, Vladimir

    2010-06-15

    A system and method for depositing ceramic materials, such as nitrides and oxides, including high temperature superconducting oxides on a tape substrate. The system includes a tape support assembly that comprises a rotatable drum. The rotatable drum supports at least one tape substrate axially disposed on the surface of the drum during the deposition of metals on the tape and subsequent oxidation to form the ceramic materials. The drum is located within a stator having a slot that is axially aligned with the drum. A space exists between the drum and stator. The space is filled with a predetermined partial pressure of a reactive gas. The drum, stator, and space are heated to a predetermined temperature. To form the ceramic material on the tape substrate, the drum is first rotated to align the tape substrate with the slot, and at least one metal is deposited on the substrate. The drum then continues to rotate, bringing the tape substrate into the space, where the metal deposited on the tape substrate reacts with the reactive gas to form the ceramic material. In one embodiment, the tape support system also includes a pay-out/take-up system that co-rotates with the drum and provides a continuous length of tape substrate.

  3. Numerical and Experimental Investigation of the Electromechanical Behavior of REBCO Tapes

    NASA Astrophysics Data System (ADS)

    Allen, N. C.; Chiesa, L.; Takayasu, M.

    2015-12-01

    To fully characterize the electromechanical behavior of a Twisted Stacked-Tape Cable (TSTC) it is important to understand the performance of the individual REBCO tapes under various loading conditions. Numerical modeling and experimentation have been used to investigate the electromechanical characteristics of two commercially available REBCO tapes (SuperPower and SuNAM). Tension and combined tension-torsion experiments on single tapes have been continued, from prior preliminary studies, to characterize their critical current behavior and mechanical strength. Additionally, structural finite element analysis was performed on single tapes under tension and combined tension-torsion to investigate the strain dependence of the critical current. The numerical results were compared to the experimental findings for validation. The SuNAM experimental data matched the numerical model very well while the SuperPower tape experienced degradation at lower stress and strain than predicted in the model. The Superpower tape also displayed greater variability in critical current between different samples as compared with the SuNAM tape.

  4. Star Catalogs on Punched Cards and Magnetic Tape

    NASA Technical Reports Server (NTRS)

    Berbert, J. H.

    1961-01-01

    In connection with the calibration of the Minitrack satellite tracking stations, the Goddard Space Flight Center has had the contents of a number of star catalogs put on punched cards and magnetic tape. This report discusses the plate data reduction procedures, briefly describes the information on the punched cards and magnetic tape, and calls attention to other applications of the card and tape star catalogs. The Goddard Space Flight Center has offered to prepare duplicate catalogs for qualified organizations.

  5. A review of Curtiss-Wright rotary engine developments with respect to general aviation potential

    NASA Technical Reports Server (NTRS)

    Jones, C.

    1979-01-01

    Aviation related rotary (Wankel-type) engine tests, possible growth directions and relevant developments at Curtiss-Wright have been reviewed. Automotive rotary engines including stratified charge are described and flight test results of rotary aircraft engines are presented. The current 300 HP engine prototype shows basic durability and competitive performance potential. Recent parallel developments have separately confirmed the geometric advantages of the rotary engine for direct injected unthrottled stratified charge. Specific fuel consumption equal to or better than pre- or swirl-chamber diesels, low emission and multi-fuel capability have been shown by rig tests of similar rotary engine.

  6. Stratified charge rotary engine for general aviation

    NASA Technical Reports Server (NTRS)

    Mount, R. E.; Parente, A. M.; Hady, W. F.

    1986-01-01

    A development history, a current development status assessment, and a design feature and performance capabilities account are given for stratified-charge rotary engines applicable to aircraft propulsion. Such engines are capable of operating on Jet-A fuel with substantial cost savings, improved altitude capability, and lower fuel consumption by comparison with gas turbine powerplants. Attention is given to the current development program of a 400-hp engine scheduled for initial operations in early 1990. Stratified charge rotary engines are also applicable to ground power units, airborne APUs, shipboard generators, and vehicular engines.

  7. Microwave lamp with multi-purpose rotary motor

    DOEpatents

    Ury, M.G.; Turner, B.; Wooten, R.D.

    1999-02-02

    In a microwave powered electrodeless lamp, a single rotary motor is used to (a) rotate the bulb and (b) provide rotary motion to a blower or pump means for providing cooling fluid to the magnetron and/or to a forced gas cooler for providing cooling gas to the bulb. The blower may consist of only of an impeller without the usual blower housing. The motor, bulb stem and bulb, or motor, bulb stem, bulb and blower may be formed as an integral unit so as to facilitate replacement. 8 figs.

  8. Microwave lamp with multi-purpose rotary motor

    DOEpatents

    Ury, Michael G.; Turner, Brian; Wooten, Robert D.

    1999-01-01

    In a microwave powered electrodeless lamp, a single rotary motor is used to a) rotate the bulb and b) provide rotary motion to a blower or pump means for providing cooling fluid to the magnetron and/or to a forced gas cooling for providing cooler gas to the bulb. The blower may consist of only of an impeller without the usual blower housing. The motor, bulb stem and bulb, or motor, bulb stem, bulb and blower may be formed as an integral unit so as to facilitate replacement.

  9. Sterilization of rotary NiTi instruments within endodontic sponges.

    PubMed

    Chan, H W A; Tan, K H; Dashper, S G; Reynolds, E C; Parashos, P

    2015-08-17

    To determine whether the following can be sterilized by autoclaving - endodontic sponges, rotary nickel-titanium (NiTi) instruments within endodontic sponges, and rotary NiTi instruments with rubber stoppers. Sixty-four samples of eight different endodontic sponges (n = 512) were placed into brain heart infusion broth (BHI) for 72 h. An aliquot of this was then spread onto horse blood agar and cultured aerobically and anaerobically to test sterility at purchase. Bacterial suspensions of Enterococcus faecalis, Porphyromonas gingivalis and Geobacillus stearothermophilus in BHI were used to contaminate sterile sponges and rotary NiTi instruments (with and without rubber stoppers) inserted into sponges. The various samples were autoclaved and then cultured aerobically and anaerobically. Success of sterilization was measured qualitatively as no growth. The experiment was repeated with clinically used rotary NiTi instruments (n = 512). All experiments were conducted in quadruplicate. No sponges on purchase had microbial growth when anaerobically cultured but some did when aerobically cultured. All autoclaved sponges and instruments (within or without sponges, and with or without rubber stoppers) were associated with no microbial growth. All nonautoclaved positive control samples showed microbial growth. Autoclaving was effective in the sterilization of sponges and endodontic instruments. Endodontic sponges should be autoclaved before clinical use. For clinical efficiency and cost-effectiveness, rotary NiTi instruments can be sterilized in endodontic sponges without removal of rubber stoppers. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  10. Undergraduate students introduction to manual and rotary root canal instrumentation.

    PubMed

    Leonardi, Denise Piotto; Haragushiku, Gisele Aihara; Tomazinho, Flavia Sens Fagundes; Furuse, Adilson Yoshio; Volpato, Lusiane; Baratto-Filho, Flares

    2012-01-01

    The aim of this study was to evaluate the performance of undergraduates in their first contact with manual and rotary root canal instrumentation. Forty-two students who had never worked on a root canal before instrumented 42 extracted lower-incisors. Participants were assigned to one of two groups: Rotary instrumentation or manual instrumentation. Pre- and post-operative computed tomography scans were obtained with a 3-dimensional dental imaging system. Starting and finishing times of preparation were recorded. The cross-sectional area of the root canal was analyzed with 2-mm-below-the-apex initial and final transverse images recorded through a digital imaging system and analyzed with software to measure the initial and final area of the root canal in mm(2). Data from the cross-sectional area of the root canal and time spent were subjected to the Mann-Whitney's U-test (p<0.05). The rotary instrumentation group showed smaller time for preparation (p=0.0204). No differences between rotary and manual instrumentation regarding the cross-sectional area of the root canal were observed (p=0.25). No accidents occurred. Undergraduate students showed good performance in their first contact with the manual and rotary instrumentation with regard to time spent and cross-sectional area of the root canal, with no operative accidents.

  11. Analytical investigation in bending characteristic of twisted stacked-tape cable conductor

    NASA Astrophysics Data System (ADS)

    Takayasu, Makoto; Chiesa, Luisa

    2015-12-01

    An analytical model to evaluate bending strains of a twisted stack-tape cable (TSTC) conductor has been developed. Through a comparison with experimental results obtained for a soldered 32-tape YBCO TSTC conductor, it has been found that a Perfect-Slip Model (PSM) taking into account the slipping between tapes in a stacked-tape cable during bending gives much better estimation of the bending performance compared to a No-Slip Model (NSM). In the PSM case the tapes can slip so that the internal longitudinal axial strain can be released. The longitudinal strains of compression and tension regions along the tape are balanced in one twist-pitch and cancel out evenly in a long cable. Therefore, in a cable the strains due to bending can be minimized. This is an important advantage of a TSTC conductor. The effect of the cable diameter size on the bending strain is also expected to be minor, and all tapes composing a TSTC conductor have the same strain response under bending, therefore the cable critical current can be characterized from a single tape behaviour.

  12. Cassette Tape Catalog: 1980/1981 Unabridged Supplement.

    ERIC Educational Resources Information Center

    American Child Care Services, Hampton, VA.

    This unabridged supplement to the Child Care Information Center's tape cassette catalog contains a listing of all recordings made in calendar years 1980 and 1981. This document plus "The Revised 1976 Cassette Tape Catalog,""The 1977 Addendum," and "The 1978/1979 Unabridged Supplement" together provide a complete listing of the 1,776 tape…

  13. "Dentinal microcracks after root canal preparation" a comparative evaluation with hand, rotary and reciprocating instrumentation.

    PubMed

    Priya, N Tulasi; Chandrasekhar, Veeramachaneni; Anita, S; Tummala, Muralidhar; Raj, T B Phanindhar; Badami, Vijetha; Kumar, Pradeep; Soujanya, E

    2014-12-01

    The purpose of this study was to compare the incidence of dentinal micro cracks after instrumentation with various types of NiTi files in rotary and reciprocating motion. One hundred human extracted mandibular central incisors were taken and divided into 10 groups (n=10 teeth per group). Group 1- No preparation, Group 2 - Hand instrumentation, Groups 3,4 - ProTaper files in rotary and reciprocating motion, Groups 5,6 - ProTaper Next files in rotary and reciprocating motion, Groups 7,8 - Oneshape files in rotary and reciprocating motion, Groups 9,10 - Reciproc files in rotary and reciprocating motion. Specimens were sectioned horizontally at 3,6 and 9 mm from the apex and dentinal micro cracks were observed under a stereomicroscope. There was a statistically significant difference between the groups (p<0.05). There were no significant differences in crack formation between the groups (Protaper Next - Rot, Protaper Next - Rec, Reciproc - Rec); (ProTaper - Rot, ProTaper - Rec, Oneshape - Rot), (Oneshape - Rot, Reciproc - Rot), (One shape Reciproc, Reciproc - Rec); (p >.05). Least cracks were seen in canals instrumented with Pro Taper Next files both in rotary and reciprocating motion. Full sequence rotary systems showed less cracks than single file systems and full sequence rotary systems showed less cracks in reciprocating motion than in rotary motion.

  14. Influence of tantalum underlayer on magnetization dynamics in Ni{sub 81}Fe{sub 19} films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kwon, Jae Hyun; Deorani, Praveen; Yoon, Jungbum

    2015-07-13

    The effect of tantalum (Ta) underlayer is investigated in Ni{sub 81}Fe{sub 19} thin films for magnetization dynamics. The damping parameters extracted from spin wave measurements increase systematically with increasing Ta thickness, whereas the damping parameters from ferromagnetic resonance measurements are found to be weakly dependent on the Ta thickness. The difference is attributed to propagating properties of spin wave and short spin diffusion length in Ta. The group velocity of spin waves is found to be constant for different Ta thicknesses, and nonreciprocity of spin waves is not affected by the Ta thickness. The experimental observations are supported by micromagneticmore » simulations.« less

  15. Rotary magnetic heat pump

    DOEpatents

    Kirol, Lance D.

    1988-01-01

    A rotary magnetic heat pump constructed without flow seals or segmented rotor accomplishes recuperation and regeneration by using split flow paths. Heat exchange fluid pumped through heat exchangers and returned to the heat pump splits into two flow components: one flowing counter to the rotor rotation and one flowing with the rotation.

  16. Simulation and analysis of tape spring for deployed space structures

    NASA Astrophysics Data System (ADS)

    Chang, Wei; Cao, DongJing; Lian, MinLong

    2018-03-01

    The tape spring belongs to the configuration of ringent cylinder shell, and the mechanical properties of the structure are significantly affected by the change of geometrical parameters. There are few studies on the influence of geometrical parameters on the mechanical properties of the tape spring. The bending process of the single tape spring was simulated based on simulation software. The variations of critical moment, unfolding moment, and maximum strain energy in the bending process were investigated, and the effects of different radius angles of section and thickness and length on driving capability of the simple tape spring was studied by using these parameters. Results show that the driving capability and resisting disturbance capacity grow with the increase of radius angle of section in the bending process of the single tape spring. On the other hand, these capabilities decrease with increasing length of the single tape spring. In the end, the driving capability and resisting disturbance capacity grow with the increase of thickness in the bending process of the single tape spring. The research has a certain reference value for improving the kinematic accuracy and reliability of deployable structures.

  17. Patellar taping, patellofemoral pain syndrome, lower extremity kinematics, and dynamic postural control.

    PubMed

    Aminaka, Naoko; Gribble, Phillip A

    2008-01-01

    Patellar taping has been a part of intervention for treatment of patellofemoral pain syndrome (PFPS). However, research on the efficacy of patellar taping on lower extremity kinematics and dynamic postural control is limited. To evaluate the effects of patellar taping on sagittal-plane hip and knee kinematics, reach distance, and perceived pain level during the Star Excursion Balance Test (SEBT) in individuals with and without PFPS. Repeated-measures design with 2 within-subjects factors and 1 between-subjects factor. The University of Toledo Athletic Training Research Laboratory. Twenty participants with PFPS and 20 healthy participants between the ages of 18 and 29 years. The participants performed 3 reaches of the SEBT in the anterior direction under tape and no-tape conditions on both legs. The participants' hip and knee sagittal-plane kinematics were measured using the electromagnetic tracking system. Reach distance was recorded by hand and was normalized by dividing the distance by the participants' leg length (%MAXD). After each taping condition on each leg, the participants rated the perceived pain level using the 10-cm visual analog scale. The participants with PFPS had a reduction in pain level with patellar tape application compared with the no-tape condition (P = .005). Additionally, participants with PFPS demonstrated increased %MAXD under the tape condition compared with the no-tape condition, whereas the healthy participants demonstrated decreased %MAXD with tape versus no tape (P = .028). No statistically significant differences were noted in hip flexion and knee flexion angles. Although patellar taping seemed to reduce pain and improve SEBT performance of participants with PFPS, the exact mechanisms of these phenomena cannot be explained in this study. Further research is warranted to investigate the effect of patellar taping on neuromuscular control during dynamic postural control.

  18. Thales Cryogenics rotary cryocoolers for HOT applications

    NASA Astrophysics Data System (ADS)

    Martin, Jean-Yves; Cauquil, Jean-Marc; Benschop, Tonny; Freche, Sébastien

    2012-06-01

    Thales Cryogenics has an extensive background in delivering reliable linear and rotary coolers for military, civil and space programs. Recent work carried out at detector level enable to consider a higher operation temperature for the cooled detectors. This has a direct impact on the cooling power required to the cryocooler. In continuation of the work presented last year, Thales cryogenics has studied the operation and optimization of the rotary cryocoolers at high cold regulation temperature. In this paper, the performances of the Thales Cryogenics rotary cryocoolers at elevated cold regulation temperature will be presented. From these results, some trade-offs can be made to combine correct operation of the cryocooler on all the ambient operational range and maximum efficiency of the cryocooler. These trade-offs and the impact on MTTF of elevated cold regulation temperature will be presented and discussed. In correlation with the increase of the cold operation temperature, the cryocooler input power is significantly decreased. As a consequence, the cooler drive electronics own consumption becomes relatively important and must be reduced in order to minimize global input power to the cooling function (cryocooler and cooler drive electronics). Thales Cryogenics has developed a new drive electronics optimized for low input power requirements. In parallel, improvements on RM1 and RM2 cryocoolers have been defined and implemented. The main impacts on performances of these new designs will be presented. Thales cryogenics is now able to propose an efficient cooling function for application requiring a high cold regulation temperature including a range of tuned rotary coolers.

  19. Dry Process for Making Polyimide/ Carbon-and-Boron-Fiber Tape

    NASA Technical Reports Server (NTRS)

    Belvin, Harry L.; Cano, Roberto J.; Johnston, Norman J.; Marchello, Joseph M.

    2003-01-01

    A dry process has been invented as an improved means of manufacturing composite prepreg tapes that consist of high-temperature thermoplastic polyimide resin matrices reinforced with carbon and boron fibers. Such tapes are used (especially in the aircraft industry) to fabricate strong, lightweight composite-material structural components. The inclusion of boron fibers results in compression strengths greater than can be achieved by use of carbon fibers alone. The present dry process is intended to enable the manufacture of prepreg tapes (1) that contain little or no solvent; (2) that have the desired dimensions, fiber areal weight, and resin content; and (3) in which all of the fibers are adequately wetted by resin and the boron fibers are fully encapsulated and evenly dispersed. Prepreg tapes must have these properties to be useable in the manufacture of high-quality composites by automated tape placement. The elimination of solvent and the use of automated tape placement would reduce the overall costs of manufacturing.

  20. LGSOWG CCT format CCB document: The standard CCT family of tape formats

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The tape format standardization approach recommended by the committee on CCT standardization is described and defined. All rules and conventions required to employ the superstructure approach to the CCT family of tape formats are presented for users of remote sensing data and producer of user tapes and the superstructure records are specified. The standard for future tape format design is presented as a guide to designing data records of a particular tape format. An example is provided showing how to incorporate the superstructure into an already established tape format.

  1. Personal miniature electrophysiological tape recorder

    NASA Astrophysics Data System (ADS)

    Green, H.

    1981-11-01

    The use of a personal miniature electrophysiological tape recorder to measure the physiological reactions of space flight personnel to space flight stress and weightlessness is described. The Oxford Instruments Medilog recorder, a battery-powered, four-channel cassette tape recorder with 24 hour endurance is carried on the person and will record EKG, EOG, EEG, and timing and event markers. The data will give information about heart rate and morphology changes, and document adaptation to zero gravity on the part of subjects who, unlike highly trained astronauts, are more representative of the normal population than were the subjects of previous space flight studies.

  2. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, E.B.; Muller, A.C.

    1983-07-15

    The present invention is a cable which, although constructed from inexpensive polyolefin tapes and using typical impregnating oils, furnishes high voltage capability up to 765 kV, and has such excellent dielectric characteristics and heat transfer properties that it is capable of operation at capacities equal to or higher than presently available cables at a given voltage. This is accomplished by using polyethylene, polybutene or polypropylene insulating tape which has been specially processed to attain properties which are not generally found in these materials, but are required for their use in impregnated electrical cables. Chief among these properties is compatibility with impregnating oil.

  3. Superconducting flat tape cable magnet

    DOEpatents

    Takayasu, Makoto

    2015-08-11

    A method for winding a coil magnet with the stacked tape cables, and a coil so wound. The winding process is controlled and various shape coils can be wound by twisting about the longitudinal axis of the cable and bending following the easy bend direction during winding, so that sharp local bending can be obtained by adjusting the twist pitch. Stack-tape cable is twisted while being wound, instead of being twisted in a straight configuration and then wound. In certain embodiments, the straight length should be half of the cable twist-pitch or a multiple of it.

  4. Dry rotary swaging with structured and coated tools

    NASA Astrophysics Data System (ADS)

    Herrmann, Marius; Schenck, Christian; Kuhfuss, Bernd

    2018-05-01

    Rotary swaging is a cold bulk forming process for manufacturing of complex bar and tube profiles like axles and gear shafts in the automotive industry. Conventional rotary swaging is carried out under intense use of lubricant usually based on mineral oil. Besides lubrication the lubricant fulfills necessary functions like lubrication, flushing and cooling, but generates costs for recycling, replacement and cleaning of the workpieces. Hence, the development of a dry process design is highly desirable, both under economic and ecological points of view. Therefore, it is necessary to substitute the functions of the lubricant. This was realized by the combination of newly developed a-C:H:W coating systems on the tools to minimize the friction and to avoid adhesion effects. With the application of a deterministic structure in the forging zone of the tools the friction conditions are modified to control the axial process forces. In this study infeed rotary swaging with functionalized tools was experimentally investigated. Therefore, steel and aluminum tubes were formed with and without lubricant. Different structures which were coated and uncoated were implemented in the reduction zone of the tools. The antagonistic effects of coating and structuring were characterized by measuring the axial process force and the produced workpiece quality in terms of roundness and surface roughness. Thus, the presented results allow for further developments towards a dry rotary swaging process.

  5. Methods and apparatus for controlling rotary machines

    DOEpatents

    Bagepalli, Bharat Sampathkumaran [Niskayuna, NY; Jansen, Patrick Lee [Scotia, NY; Barnes, Gary R [Delanson, NY; Fric, Thomas Frank [Greer, SC; Lyons, James Patrick Francis [Niskayuna, NY; Pierce, Kirk Gee [Simpsonville, SC; Holley, William Edwin [Greer, SC; Barbu, Corneliu [Guilderland, NY

    2009-09-01

    A control system for a rotary machine is provided. The rotary machine has at least one rotating member and at least one substantially stationary member positioned such that a clearance gap is defined between a portion of the rotating member and a portion of the substantially stationary member. The control system includes at least one clearance gap dimension measurement apparatus and at least one clearance gap adjustment assembly. The adjustment assembly is coupled in electronic data communication with the measurement apparatus. The control system is configured to process a clearance gap dimension signal and modulate the clearance gap dimension.

  6. 75 FR 14628 - Pressure Sensitive Plastic Tape From Italy; Determination

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-26

    ... Plastic Tape From Italy; Determination On the basis of the record \\1\\ developed in the subject five-year... pressure sensitive plastic tape from Italy would be likely to lead to continuation or recurrence of... Publication 4128 (March 2010), entitled Pressure Sensitive Plastic Tape from Italy: Investigation No. AA1921...

  7. Node, Node-Link, and Node-Link-Group Diagrams: An Evaluation.

    PubMed

    Saket, Bahador; Simonetto, Paolo; Kobourov, Stephen; Börner, Katy

    2014-12-01

    Effectively showing the relationships between objects in a dataset is one of the main tasks in information visualization. Typically there is a well-defined notion of distance between pairs of objects, and traditional approaches such as principal component analysis or multi-dimensional scaling are used to place the objects as points in 2D space, so that similar objects are close to each other. In another typical setting, the dataset is visualized as a network graph, where related nodes are connected by links. More recently, datasets are also visualized as maps, where in addition to nodes and links, there is an explicit representation of groups and clusters. We consider these three Techniques, characterized by a progressive increase of the amount of encoded information: node diagrams, node-link diagrams and node-link-group diagrams. We assess these three types of diagrams with a controlled experiment that covers nine different tasks falling broadly in three categories: node-based tasks, network-based tasks and group-based tasks. Our findings indicate that adding links, or links and group representations, does not negatively impact performance (time and accuracy) of node-based tasks. Similarly, adding group representations does not negatively impact the performance of network-based tasks. Node-link-group diagrams outperform the others on group-based tasks. These conclusions contradict results in other studies, in similar but subtly different settings. Taken together, however, such results can have significant implications for the design of standard and domain snecific visualizations tools.

  8. Geared Electromechanical Rotary Joint

    NASA Technical Reports Server (NTRS)

    Vranish, John M.

    1994-01-01

    Geared rotary joint provides low-noise ac or dc electrical contact between electrical subsystems rotating relative to each other. Designed to overcome some disadvantages of older electromechanical interfaces, especially intermittency of sliding-contact and rolling-contact electromechanical joints. Hollow, springy planetary gears provide continuous, redundant, low-noise electrical contact between inner and outer gears.

  9. Rotary magnetic heat pump

    DOEpatents

    Kirol, L.D.

    1987-02-11

    A rotary magnetic heat pump constructed without flow seals or segmented rotor accomplishes recuperation and regeneration by using split flow paths. Heat exchange fluid pumped through heat exchangers and returned to the heat pump splits into two flow components: one flowing counter to the rotor rotation and one flowing with the rotation. 5 figs.

  10. STS-88 Mission Highlights Resources Tape. Tape B

    NASA Technical Reports Server (NTRS)

    1999-01-01

    The STS-88 flight crew, Commander Robert D. Cabana, Pilot Frederick W. Sturckow, and Mission Specialists Nancy J. Currie, James H. Newman, Jerry L. Ross, and Sergei Krikalev present a video overview of their space flight. Tape two of three includes the installation of an S-Band to help monitor the UNITY Connecting Module, the opening of UNITY's hatch, the opening of the main compartment hatch to ZARYA Control Module, and the repair of the inflight maintenance system.

  11. Rapid prototyping of microfluidic systems using a PDMS/polymer tape composite.

    PubMed

    Kim, Jungkyu; Surapaneni, Rajesh; Gale, Bruce K

    2009-05-07

    Rapid prototyping of microfluidic systems using a combination of double-sided tape and PDMS (polydimethylsiloxane) is introduced. PDMS is typically difficult to bond using adhesive tapes due to its hydrophobic nature and low surface energy. For this reason, PDMS is not compatible with the xurography method, which uses a knife plotter and various adhesive coated polymer tapes. To solve these problems, a PDMS/tape composite was developed and demonstrated in microfluidic applications. The PDMS/tape composite was created by spinning it to make a thin layer of PDMS over double-sided tape. Then the PDMS/tape composite was patterned to create channels using xurography, and bonded to a PDMS slab. After removing the backing paper from the tape, a complete microfluidic system could be created by placing the construct onto nearly any substrate; including glass, plastic or metal-coated glass/silicon substrates. The bond strength was shown to be sufficient for the pressures that occur in typical microfluidic channels used for chemical or biological analysis. This method was demonstrated in three applications: standard microfluidic channels and reactors, a microfluidic system with an integrated membrane, and an electrochemical biosensor. The PDMS/tape composite rapid prototyping technique provides a fast and cost effective fabrication method and can provide easy integration of microfluidic channels with sensors and other components without the need for a cleanroom facility.

  12. Effect of chemoepitaxial guiding underlayer design on the pattern quality and shape of aligned lamellae for fabrication of line-space patterns

    NASA Astrophysics Data System (ADS)

    Nation, Benjamin D.; Peters, Andrew J.; Lawson, Richard A.; Ludovice, Peter J.; Henderson, Clifford L.

    2017-10-01

    Chemoepitaxial guidance of block copolymer directed self-assembly in thin films is explored using a coarse-grained molecular dynamics model. The underlayers studied are 2× density multiplying line-space patterns composed of repeating highly preferential pinning stripes of various widths separated by larger, more neutral, background regions of various compositions. Decreasing the pinning stripe width or making the background region more neutral is found to increase the line edge roughness (LER) of the lines, but these conditions are found to give the straightest sidewalls for the formed lines. Varying these underlayer properties is found to have minimal effect on linewidth roughness. A larger pinning stripe causes the pinned line (PL) to foot (expand near the substrate), and a preferential background region causes the unpinned line (UPL) to undercut (contract near the substrate). A simple model was developed to predict the optimal conditions to eliminate footing. Using this model, conditions are found that decrease footing of the PL, but these conditions increase undercutting in the UPL. Deformations in either the PL or UPL propagate to the other line. There exists a trade-off between LER and the footing/undercutting, that is, decreasing LER increases footing/undercutting and vice versa.

  13. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  14. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  15. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  16. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  17. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  18. Ankle taping does not impair performance in jump or balance tests.

    PubMed

    Abián-Vicén, Javier; Alegre, Luis M; Fernández-Rodríguez, J Manuel; Lara, Amador J; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96). The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed. Key pointsAnkle taping has no influence on balance performance.Ankle taping does not impair performance during the push-off phase of the jump.Ankle taping could increase the risk of injury during landings by increasing peak forces.

  19. Ankle Taping Does Not Impair Performance in Jump or Balance Tests

    PubMed Central

    Abián-Vicén, Javier; Alegre, Luis M.; Fernández-Rodríguez, J. Manuel; Lara, Amador J.; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96). The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed. Key pointsAnkle taping has no influence on balance performance.Ankle taping does not impair performance during the push-off phase of the jump.Ankle taping could increase the risk of injury during landings by increasing peak forces. PMID:24149902

  20. Gait Kinematics After Taping in Participants With Chronic Ankle Instability

    PubMed Central

    Chinn, Lisa; Dicharry, Jay; Hart, Joseph M.; Saliba, Susan; Wilder, Robert; Hertel, Jay

    2014-01-01

    Context: Chronic ankle instability is characterized by repetitive lateral ankle sprains. Prophylactic ankle taping is a common intervention used to reduce the risk of ankle sprains. However, little research has been conducted to evaluate the effect ankle taping has on gait kinematics. Objective: To investigate the effect of taping on ankle and knee kinematics during walking and jogging in participants with chronic ankle instability. Design: Controlled laboratory study. Setting: Motion analysis laboratory. Patients or Participants: A total of 15 individuals (8 men, 7 women; age = 26.9 ± 6.8 years, height = 171.7 ± 6.3 cm, mass = 73.5 ± 10.7 kg) with self-reported chronic ankle instability volunteered. They had an average of 5.3 ± 3.1 incidences of ankle sprain. Intervention(s): Participants walked and jogged in shoes on a treadmill while untaped and taped. The tape technique was a traditional preventive taping procedure. Conditions were randomized. Main Outcome Measure(s): Frontal-plane and sagittal-plane ankle and sagittal-plane knee kinematics were recorded throughout the entire gait cycle. Group means and 90% confidence intervals were calculated, plotted, and inspected for percentages of the gait cycle in which the confidence intervals did not overlap. Results: During walking, participants were less plantar flexed from 64% to 69% of the gait cycle (mean difference = 5.73° ± 0.54°) and less inverted from 51% to 61% (mean difference = 4.34° ± 0.65°) and 76% to 81% (mean difference = 5.55° ± 0.54°) of the gait cycle when taped. During jogging, participants were less dorsiflexed from 12% to 21% (mean difference = 4.91° ± 0.18°) and less inverted from 47% to 58% (mean difference = 6.52° ± 0.12°) of the gait cycle when taped. No sagittal-plane knee kinematic differences were found. Conclusions: In those with chronic ankle instability, taping resulted in a more neutral ankle position during walking and jogging in shoes on a treadmill. This change in

  1. Multi-Fuel Rotary Engine for General Aviation Aircraft

    NASA Technical Reports Server (NTRS)

    Jones, C.; Ellis, D. R.; Meng, P. R.

    1983-01-01

    Design studies, conducted for NASA, of Advanced Multi-fuel General Aviation and Commuter Aircraft Rotary Stratified Charge Engines are summarized. Conceptual design studies of an advanced engine sized to provide 186/250 shaft KW/HP under cruise conditions at 7620/25,000 m/ft. altitude were performed. Relevant engine development background covering both prior and recent engine test results of the direct injected unthrottled rotary engine technology, including the capability to interchangeably operate on gasoline, diesel fuel, kerosene, or aviation jet fuel, are presented and related to growth predictions. Aircraft studies, using these resultant growth engines, define anticipated system effects of the performance and power density improvements for both single engine and twin engine airplanes. The calculated results indicate superior system performance and 30 to 35% fuel economy improvement for the Rotary-engine airplanes as compared to equivalent airframe concept designs with current baseline engines. The research and technology activities required to attain the projected engine performance levels are also discussed.

  2. A novel optical rotary encoder with eccentricity self-detection ability.

    PubMed

    Li, Xuan; Ye, Guoyong; Liu, Hongzhong; Ban, Yaowen; Shi, Yongsheng; Yin, Lei; Lu, Bingheng

    2017-11-01

    Eccentricity error is the main error source of optical rotary encoders. Real-time detection and compensation of the eccentricity error is an effective way of improving the accuracy of rotary optical encoders. In this paper, a novel rotary optical encoder is presented to realize eccentricity self-detection. The proposed encoder adopts a spider-web-patterned scale grating as a measuring standard which is scanned by a dual-head scanning unit. Two scanning heads of the dual-head scanning unit, which are arranged orthogonally, have the function of scanning the periodic pattern of the scale grating along the angular and radial directions, respectively. By this means, synchronous measurement of angular and radial displacements of the scale grating is realized. This paper gives the details of the operating principle of the rotary optical encoder, developing and testing work of a prototype. The eccentricity self-detection result agrees well with the result measured by an optical microscope. The experimental result preliminarily proves the feasibility and effectiveness of the proposed optical encoder.

  3. A novel optical rotary encoder with eccentricity self-detection ability

    NASA Astrophysics Data System (ADS)

    Li, Xuan; Ye, Guoyong; Liu, Hongzhong; Ban, Yaowen; Shi, Yongsheng; Yin, Lei; Lu, Bingheng

    2017-11-01

    Eccentricity error is the main error source of optical rotary encoders. Real-time detection and compensation of the eccentricity error is an effective way of improving the accuracy of rotary optical encoders. In this paper, a novel rotary optical encoder is presented to realize eccentricity self-detection. The proposed encoder adopts a spider-web-patterned scale grating as a measuring standard which is scanned by a dual-head scanning unit. Two scanning heads of the dual-head scanning unit, which are arranged orthogonally, have the function of scanning the periodic pattern of the scale grating along the angular and radial directions, respectively. By this means, synchronous measurement of angular and radial displacements of the scale grating is realized. This paper gives the details of the operating principle of the rotary optical encoder, developing and testing work of a prototype. The eccentricity self-detection result agrees well with the result measured by an optical microscope. The experimental result preliminarily proves the feasibility and effectiveness of the proposed optical encoder.

  4. Application of a magnetic fluid seal to rotary blood pumps

    NASA Astrophysics Data System (ADS)

    Mitamura, Y.; Arioka, S.; Sakota, D.; Sekine, K.; Azegami, M.

    2008-05-01

    A magnetic fluid seal enables mechanical contact-free rotation of a shaft without frictional heat and material wear and hence has excellent durability. However, the durability of a magnetic fluid seal decreases in liquid. The life of a seal applied to a rotary blood pump is not known. We have developed a magnetic fluid seal that has a shield mechanism minimizing the influence of the rotary pump on the magnetic fluid. The developed magnetic fluid seal worked for over 286 days in a continuous flow condition, for 24 days (on-going) in a pulsatile flow condition and for 24 h (electively terminated) in blood flow. The magnetic fluid seal is promising as a shaft seal for rotary blood pumps.

  5. RESIDUAL RISK ASSESSMENT: MAGNETIC TAPE ...

    EPA Pesticide Factsheets

    This document describes the residual risk assessment for the Magnetic Tape Manufacturing source category. For stationary sources, section 112 (f) of the Clean Air Act requires EPA to assess risks to human health and the environment following implementation of technology-based control standards. If these technology-based control standards do not provide an ample margin of safety, then EPA is required to promulgate addtional standards. This document describes the methodology and results of the residual risk assessment performed for the Magnetic Tape Manufacturing source category. The results of this analyiss will assist EPA in determining whether a residual risk rule for this source category is appropriate.

  6. Choice reaction time to visual motion during prolonged rotary motion in airline pilots

    NASA Technical Reports Server (NTRS)

    Stewart, J. D.; Clark, B.

    1975-01-01

    Thirteen airline pilots were studied to determine the effect of preceding rotary accelerations on the choice reaction time to the horizontal acceleration of a vertical line on a cathode-ray tube. On each trial, one of three levels of rotary and visual acceleration was presented with the rotary stimulus preceding the visual by one of seven periods. The two accelerations were always equal and were presented in the same or opposite directions. The reaction time was found to increase with increases in the time the rotary acceleration preceded the visual acceleration, and to decrease with increased levels of visual and rotary acceleration. The reaction time was found to be shorter when the accelerations were in the same direction than when they were in opposite directions. These results suggest that these findings are a special case of a general effect that the authors have termed 'gyrovisual modulation'.

  7. The statistical evaluation of duct tape end match as physical evidence

    NASA Astrophysics Data System (ADS)

    Chan, Ka Lok

    Duct tapes are often submitted to crime laboratories as evidence associated with abductions, homicides, or construction of explosive devices. As a result, trace evidence examiners are often asked to analyze and compare commercial duct tapes so that they can establish possible evidentiary links. Duct tape end matches are believed to be the strongest association between exemplar and question samples because they are considered as evidence with unique individual characteristics. While end match analysis and comparison have long been undertaken by trace evidence examiners, there is a significant lack of scientific research for associating two or more segments of duct tapes. This study is designed to obtain statistical inferences on the uniqueness of duct tape tears. Three experiments were devised to compile the basis for a statistical assessment of the probability of duct tape end matches along with a proposed error rate. In one experiment, we conducted the equivalent of 10,000 end match examinations with an error rate of 0%. In the second experiment, we performed 2,704 end match examinations having 0% error rate. In the third experiment, using duct tape by an Elmendorf Tear tester, we conducted 576 end match examinations with an error rate of 0% and having all samples correctly associated. The results of this study indicate that end matches are distinguishable among a single roll of duct tape and between two different rolls of duct tape having very similar surface features and weave pattern.

  8. Kinesio® Tape Barrier Does Not Inhibit Intramuscular Cooling During Cryotherapy.

    PubMed

    Lyman, Katie J; McCrone, Michael; Hanson, Thomas A; Mellinger, Christopher D; Gange, Kara

    2018-05-29

    Allied health care professionals commonly apply cryotherapy as treatment for acute musculoskeletal trauma and the associated symptoms. Understanding the impact of a tape barrier on intramuscular temperature can assist in determining treatment duration for effective cryotherapy. To determine whether Kinesio® Tape acts as a barrier that affects intramuscular temperature during cryotherapy application. A repeated-measures, counterbalanced design in which the independent variable was tape application and the dependent variable was muscle temperature as measured by thermocouples placed 1 cm beneath the adipose layer. Additional covariates for robustness were BMI and adipose thickness. University research laboratory. 19 male college students with no contraindications to cryotherapy, no known sensitivity to Kinesio® Tape, and no reported quadriceps injury within the past six months. Topical cryotherapy: crushed-ice bags of 1 kg and 0.5 kg. Intramuscular temperature. The tape barrier had no statistically significant effect on muscle temperature. The pattern of temperature change was indistinguishable between participants with and without tape application. Findings suggest health care professionals can combine cryotherapy with a Kinesio® Tape application without any need for adjustments to cryotherapy duration.

  9. Chemistry of cometary meteoroids from video-tape records of meteor spectra

    NASA Technical Reports Server (NTRS)

    Millman, P. M.

    1982-01-01

    The chemistry of the cometary meteoroids was studied by closed circuit television observing systems. Vidicon cameras produce basic data on standard video tape and enable the recording of the spectra of faint shower meteors, consequently the chemical study is extended to smaller particles and we have a larger data bank than is available from the more conventional method of recording meteor spectra by photography. The two main problems in using video tape meteor spectrum records are: (1) the video tape recording has a much lower resolution than the photographic technique; (2) video tape is relatively new type of data storage in astronomy and the methods of quantitative photometry have not yet been fully developed in the various fields where video tape is used. The use of the most detailed photographic meteor spectra to calibrate the video tape records and to make positive identification of the more prominent chemical elements appearing in the spectra may solve the low resolution problem. Progress in the development of standard photometric techniques for the analysis of video tape records of meteor spectra is reported.

  10. Analysis of particulates on tape lift samples

    NASA Astrophysics Data System (ADS)

    Moision, Robert M.; Chaney, John A.; Panetta, Chris J.; Liu, De-Ling

    2014-09-01

    Particle counts on tape lift samples taken from a hardware surface exceeded threshold requirements in six successive tests despite repeated cleaning of the surface. Subsequent analysis of the particle size distributions of the failed tests revealed that the handling and processing of the tape lift samples may have played a role in the test failures. In order to explore plausible causes for the observed size distribution anomalies, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and time-of-flight secondary ion mass spectrometry (ToF-SIMS) were employed to perform chemical analysis on collected particulates. SEM/EDX identified Na and S containing particles on the hardware samples in a size range identified as being responsible for the test failures. ToF-SIMS was employed to further examine the Na and S containing particulates and identified the molecular signature of sodium alkylbenzene sulfonates, a common surfactant used in industrial detergent. The root cause investigation suggests that the tape lift test failures originated from detergent residue left behind on the glass slides used to mount and transport the tape following sampling and not from the hardware surface.

  11. Recent developments in rotary-wing aerodynamic theory

    NASA Technical Reports Server (NTRS)

    Johnson, W.

    1986-01-01

    Current progress in the computational analysis of rotary-wing flowfields is surveyed, and some typical results are presented in graphs. Topics examined include potential theory, rotating coordinate systems, lifting-surface theory (moving singularity, fixed wing, and rotary wing), panel methods (surface singularity representations, integral equations, and compressible flows), transonic theory (the small-disturbance equation), wake analysis (hovering rotor-wake models and transonic blade-vortex interaction), limitations on computational aerodynamics, and viscous-flow methods (dynamic-stall theories and lifting-line theory). It is suggested that the present algorithms and advanced computers make it possible to begin working toward the ultimate goal of turbulent Navier-Stokes calculations for an entire rotorcraft.

  12. Efficient Access to Massive Amounts of Tape-Resident Data

    NASA Astrophysics Data System (ADS)

    Yu, David; Lauret, Jérôme

    2017-10-01

    Randomly restoring files from tapes degrades the read performance primarily due to frequent tape mounts. The high latency and time-consuming tape mount and dismount is a major issue when accessing massive amounts of data from tape storage. BNL’s mass storage system currently holds more than 80 PB of data on tapes, managed by HPSS. To restore files from HPSS, we make use of a scheduler software, called ERADAT. This scheduler system was originally based on code from Oak Ridge National Lab, developed in the early 2000s. After some major modifications and enhancements, ERADAT now provides advanced HPSS resource management, priority queuing, resource sharing, web-browser visibility of real-time staging activities and advanced real-time statistics and graphs. ERADAT is also integrated with ACSLS and HPSS for near real-time mount statistics and resource control in HPSS. ERADAT is also the interface between HPSS and other applications such as the locally developed Data Carousel, providing fair resource-sharing policies and related capabilities. ERADAT has demonstrated great performance at BNL.

  13. Conditioning of material properties by micro rotary swaging

    NASA Astrophysics Data System (ADS)

    Ishkina, Svetlana; Schenck, Christian; Kuhfuss, Bernd

    2018-05-01

    Cold forming initiates a change of the material properties like flow stress and hardness. Due to work hardening and the accompanied loss of formability some intermediate heat treatment may become necessary in multi-stage forming processes. One possibility to avoid this heat treatment is to adjust the forming characteristics in terms of flow stress and formability by rotary swaging. This process is particularly suitable not only for producing of the target geometry but also for modifying of the material properties during the process and thus, rotary swaging can prepare the parts for further forming, such as extrusion. In this contribution, the process chain "rotary swaging - extrusion" for austenite stainless steel AISI304 was investigated. The forming characteristics of the semi-finished products for the extrusion were influenced by the previous swaging process. The conditioning by changing of the microstructure, the work hardening and the geometry of the processed wires was achieved by the process design. For this purpose, the geometry of the swaging dies, the feeding velocity as well as the process kinematics (eccentric swaging) and a stroke following angle Δɸ were varied. In particular, the novel geometry of the swaging dies with extraordinary sloped faces generated a non-symmetric material flow with severe shear deformation and thus an extreme change of the microstructure. The required forming force of the following extrusion process reflected the range of achievable conditioning. The micro rotary swaging process positively improved the formability of AISI304 by work softening.

  14. Rotary piston blood pumps: past developments and future potential of a unique pump type.

    PubMed

    Wappenschmidt, Johannes; Autschbach, Rüdiger; Steinseifer, Ulrich; Schmitz-Rode, Thomas; Margreiter, Raimund; Klima, Günter; Goetzenich, Andreas

    2016-08-01

    The design of implantable blood pumps is either based on displacement pumps with membranes or rotary pumps. Both pump types have limitations to meet the clinical requirements. Rotary piston blood pumps have the potential to overcome these limitations and to merge the benefits. Compared to membrane pumps, they are smaller and with no need for wear-affected membranes and valves. Compared to rotary pumps, the blood flow is pulsatile instead of a non-physiological continuous flow. Furthermore, the risk of flow-induced blood damage and platelet activation may be reduced due to low shear stress to the blood. The past developments of rotary piston blood pumps are summarized and the main problem for long-term application is identified: insufficient seals. A new approach with seal-less drives is proposed and current research on a simplified rotary piston design is presented. Expert commentary: The development of blood pumps focuses mainly on the improvement of rotary pumps. However, medical complications indicate that inherent limitations of this pump type remain and restrict the next substantial step forward in the therapy of heart failure patients. Thus, research on different pump types is reasonable. If the development of reliable drives and bearings succeeds, rotary piston blood pumps become a promising alternative.

  15. Effects of kinesio taping and hot packs on premenstrual syndrome in females.

    PubMed

    Choi, Jung-Hyun

    2017-09-01

    [Purpose] This study aimed to evaluate the effects of taping and hot packs on premenstrual syndrome, in an attempt to generate basic data for physical therapy intervention for premenstrual syndrome. [Subjects and Methods] Thirty-two females in their 20s with premenstrual syndrome were randomly assigned to a taping group (n=10), hot pack group (n=11), and taping with hot pack group (n=11). Premenstrual syndrome was assessed using the Menstrual Distress Questionnaire in each participant prior to intervention and was re-assessed after applying kinesio taping and/or hot pack from 10 days before the estimated date of menstruation until the first day of menstruation. [Results] Data revealed that the taping and taping with hot pack groups showed significantly reduced premenstrual syndrome following intervention. In terms of the differences in the Menstrual Distress Questionnaire total score among the groups, the taping with hot pack and hot pack groups showed a significant difference. [Conclusion] These findings indicate that kinesio taping is an easy, non-drug intervention for female college students with premenstrual syndrome.

  16. Effects of kinesio taping and hot packs on premenstrual syndrome in females

    PubMed Central

    Choi, Jung-Hyun

    2017-01-01

    [Purpose] This study aimed to evaluate the effects of taping and hot packs on premenstrual syndrome, in an attempt to generate basic data for physical therapy intervention for premenstrual syndrome. [Subjects and Methods] Thirty-two females in their 20s with premenstrual syndrome were randomly assigned to a taping group (n=10), hot pack group (n=11), and taping with hot pack group (n=11). Premenstrual syndrome was assessed using the Menstrual Distress Questionnaire in each participant prior to intervention and was re-assessed after applying kinesio taping and/or hot pack from 10 days before the estimated date of menstruation until the first day of menstruation. [Results] Data revealed that the taping and taping with hot pack groups showed significantly reduced premenstrual syndrome following intervention. In terms of the differences in the Menstrual Distress Questionnaire total score among the groups, the taping with hot pack and hot pack groups showed a significant difference. [Conclusion] These findings indicate that kinesio taping is an easy, non-drug intervention for female college students with premenstrual syndrome. PMID:28931978

  17. New Ultra-High Sensitivity, Absolute, Linear, and Rotary Encoders

    NASA Technical Reports Server (NTRS)

    Leviton, Douglas B.

    1998-01-01

    Several new types of absolute optical encoders of both rotary and linear function are discussed. The means for encoding are complete departures from conventional optical encoders and offer advantages of compact form, immunity to damage-induced dropouts of position information, and about an order of magnitude higher sensitivity over what is commercially available. Rotary versions have sensitivity from 0.02 arcseconds down to 0.003 arcsecond while linear models have sensitivity of 10 nm.

  18. A new concept for a hubless rotary jet

    NASA Technical Reports Server (NTRS)

    Garris, C. A.; Toh, K. H.; Xie, L.

    1991-01-01

    The 'hubless rotary-jet' thrust augmentor primary-stream configuration is proposed as a way of overcoming problems encountered with hubbed rotary-jet ejectors while retaining sufficient geometrical simplicity to facilitate performance characterization and prediction via such commercially available CFD methods as FLOTRAN, as well as verification via LDV mapping. The present discussion is conducted with a view to the contributions of more realistic performance models incorporating turbulent mixing and compressibility. Attention is given to thrust augmentation ratio vs. spin angles for various area ratios with and without mixing.

  19. Digital optical tape: Technology and standardization issues

    NASA Technical Reports Server (NTRS)

    Podio, Fernando L.

    1996-01-01

    During the coming years, digital data storage technologies will continue an aggressive growth to satisfy the user's need for higher storage capacities, higher data transfer rates and long-term archival media properties. Digital optical tape is a promising technology to satisfy these user's needs. As any emerging data storage technology, the industry faces many technological and standardization challenges. The technological challenges are great, but feasible to overcome. Although it is too early to consider formal industry standards, the optical tape industry has decided to work together by initiating prestandardization efforts that may lead in the future to formal voluntary industry standards. This paper will discuss current industry optical tape drive developments and the types of standards that will be required for the technology. The status of current industry prestandardization efforts will also be discussed.

  20. Dialects for the Stage: A Manual and Two Casette Tapes.

    ERIC Educational Resources Information Center

    Machlin, Evangeline

    This document contains a manual and two cassette tapes designed to help actors and actresses learn to speak various dialects. The tapes and the manual are arranged for the play-it-and-say-it method of dialect acquisition. The first three parts discuss the tapes and the manual in general, the dialect texts and dialect data, and the steps involved…

  1. Methods of Measuring Stress Relaxation in Composite Tape Springs

    DTIC Science & Technology

    2015-03-26

    plate in order to spread the load evenly and prevent excess torque . The plate also allows for force on the tape spring to be applied to the entire...aluminum squares that can be tightened to the base. The test fixture is secured to the marble base. The tape springs are folded in three locations with...top plate is pressed down by tightening the bolt on each nut. The tightening is complete when the tape spring just begins to create an M shape and

  2. Rotary Balance Wind Tunnel Testing for the FASER Flight Research Aircraft

    NASA Technical Reports Server (NTRS)

    Denham, Casey; Owens, D. Bruce

    2016-01-01

    Flight dynamics research was conducted to collect and analyze rotary balance wind tunnel test data in order to improve the aerodynamic simulation and modeling of a low-cost small unmanned aircraft called FASER (Free-flying Aircraft for Sub-scale Experimental Research). The impetus for using FASER was to provide risk and cost reduction for flight testing of more expensive aircraft and assist in the improvement of wind tunnel and flight test techniques, and control laws. The FASER research aircraft has the benefit of allowing wind tunnel and flight tests to be conducted on the same model, improving correlation between wind tunnel, flight, and simulation data. Prior wind tunnel tests include a static force and moment test, including power effects, and a roll and yaw damping forced oscillation test. Rotary balance testing allows for the calculation of aircraft rotary derivatives and the prediction of steady-state spins. The rotary balance wind tunnel test was conducted in the NASA Langley Research Center (LaRC) 20-Foot Vertical Spin Tunnel (VST). Rotary balance testing includes runs for a set of given angular rotation rates at a range of angles of attack and sideslip angles in order to fully characterize the aircraft rotary dynamics. Tests were performed at angles of attack from 0 to 50 degrees, sideslip angles of -5 to 10 degrees, and non-dimensional spin rates from -0.5 to 0.5. The effects of pro-spin elevator and rudder deflection and pro- and anti-spin elevator, rudder, and aileron deflection were examined. The data are presented to illustrate the functional dependence of the forces and moments on angle of attack, sideslip angle, and angular rate for the rotary contributions to the forces and moments. Further investigation is necessary to fully characterize the control effectors. The data were also used with a steady state spin prediction tool that did not predict an equilibrium spin mode.

  3. Direction control of anisotropy in the soft-magnetic underlayer for L10 Fe-Pt perpendicular media

    NASA Astrophysics Data System (ADS)

    Suzuki, Toshio

    2005-05-01

    Induced anisotropy of soft-magnetic underlayers (SUL) were pinned to radial and circumferential directions in double-layered perpendicular media, and effects of the directions on recording properties were studied for Fe-Pt media. A medium with the SUL of radial anisotropy showed a sharper cross-track profile than that of a medium with the SUL of circumferential anisotropy. Furthermore, signal-to-noise ratio (SNR) of the former was found to be 4dB higher than that of the latter at 500kfrpi. A SUL of radial anisotropy with an anisotropy-dispersion narrower could result in suppressing the fluctuation of write-field gradient and lead to further high SNR.

  4. Freeze Tape Casting of Functionally Graded Porous Ceramics

    NASA Technical Reports Server (NTRS)

    Sofie, Stephen W.

    2007-01-01

    Freeze tape casting is a means of making preforms of ceramic sheets that, upon subsequent completion of fabrication processing, can have anisotropic and/or functionally graded properties that notably include aligned and graded porosity. Freeze tape casting was developed to enable optimization of the microstructures of porous ceramic components for use as solid oxide electrodes in fuel cells: Through alignment and grading of pores, one can tailor surface areas and diffusion channels for flows of gas and liquid species involved in fuel-cell reactions. Freeze tape casting offers similar benefits for fabrication of optimally porous ceramics for use as catalysts, gas sensors, and filters.

  5. Multilingual health education tapes project.

    PubMed

    Vryheid, R

    1992-01-01

    The success of Thailand's 1985 malaria education cassette tapes project motivated the Highland Development Program to produce tapes in 6 tribal languages on family planning, maternal and child health, nutrition, and disease prevention. Staff produced tapes using a drama or radio magazine format as a series of short features with music and sound effects. Scriptwriters consulted villagers, broadcasting professionals, research workers, and health officials to tailor messages to the various hill tribes. They tried to avoid conflict between traditional and modern concepts and to minimize distrust of government services. The scriptwriters used basically short, grammatically simple sentences, and colloquial Thai to simplify translation. The staff tried to recruit literate, adult, native speakers of the target languages with some experience in health education in their own languages. Obstacles encountered with translation included some languages used an uncommon alphabet or translators did not know their own alphabet. The program backtranslated the scripts to assure the accuracy of the messages and the appropriateness of the words used. Backtranslation revealed deficiencies in the translated messages. Altering the meaning of technical terms tended to be simple mistakes, words with multiple meanings, and exaggeration of problems and/or solutions. Translators also sometimes failed to adapt cultural ideas to those of their tribes. For example, some persons translated all possible misconceptions about a disease yet the tribes did not have all the misconceptions. As of early 1992, recording, pretesting, distribution, and follow up had not yet taken place. The staff should meet with a recording studio to coordinate production including technicians and translators identifying means to communicate. Staff should be aware of signs of poor translation which they may have missed earlier and surfaces during recording. Pretesting should occur among literate and illiterate members of

  6. A Meta-Analysis of the Taped Problems Intervention

    ERIC Educational Resources Information Center

    Kleinert, Whitney L.; Codding, Robin S.; Minami, Takuya; Gould, Kaitlin

    2018-01-01

    Taped problems is an intervention strategy for addressing mathematics fluency that has been evaluated in multiple single-case design studies. Although its efficacy has been supported in individual studies, no comprehensive quantitative synthesis has been conducted on taped problems. The purpose of this study was to synthesize the literature that…

  7. Application of a magnetic fluid seal to rotary blood pumps.

    PubMed

    Mitamura, Y; Arioka, S; Sakota, D; Sekine, K; Azegami, M

    2008-05-21

    A magnetic fluid seal enables mechanical contact-free rotation of a shaft without frictional heat and material wear and hence has excellent durability. However, the durability of a magnetic fluid seal decreases in liquid. The life of a seal applied to a rotary blood pump is not known. We have developed a magnetic fluid seal that has a shield mechanism minimizing the influence of the rotary pump on the magnetic fluid. The developed magnetic fluid seal worked for over 286 days in a continuous flow condition, for 24 days (on-going) in a pulsatile flow condition and for 24 h (electively terminated) in blood flow. The magnetic fluid seal is promising as a shaft seal for rotary blood pumps.

  8. Performance of rotary kiln reactor for the elephant grass pyrolysis.

    PubMed

    De Conto, D; Silvestre, W P; Baldasso, C; Godinho, M

    2016-10-01

    The influence of process conditions (rotary speed/temperature) on the performance of a rotary kiln reactor for non-catalytic pyrolysis of a perennial grass (elephant grass) was investigated. The product yields, the production of non-condensable gases as well as the biochar properties were evaluated. The maximum H2 yield was close to that observed for catalytic pyrolysis processes, while the bio-oil yield was higher than reported for pyrolysis of other biomass in rotary kiln reactors. A H2/CO ratio suitable for Fischer-Tropsch synthesis (FTS) was obtained. The biochars presented an alkaline pH (above 10) and interesting contents of nutrients, as well as low electrical conductivity, indicating a high potential as soil amendment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Decomposition of ultrathin LiF cathode underlayer in organic-based devices evidenced by ToF-SIMS depth profiling

    NASA Astrophysics Data System (ADS)

    Pakhomov, Georgy L.; Drozdov, Mikhail N.; Travkin, Vlad V.; Bochkarev, Mikhail N.

    2017-11-01

    In this work we investigate the chemical composition of an archetypal thin-film organic device with the Ag/LiF cathode using the time-of-flight secondary ion mass spectrometry (ToF-SIMS) with depth profiling. The LiF cathode underlayer is partly decomposed because a significant amount of lithium is released into the bulk of the multilayer device. The released lithium diffuses all the way to the substrate, accumulating, as revealed by ToF-SIMS depth profiles, at the interfaces rather than uniformly doping the underlying layers. Particularly, the bottom anode becomes chemically modified.

  10. Ankle taping: support given by different materials.

    PubMed Central

    Capasso, G; Maffulli, N; Testa, V

    1989-01-01

    Three different adhesive and two non-adhesive tapes were used by three operators to assess the compressive action exerted on the ankle at the moment of strapping, during different phases of gait, and after some days of treatment in ten volunteers. Only the adhesive tapes were still able to prevent swelling after five days. They should be used if a prolonged compressive action is required. Images Figure 1 PMID:2517042

  11. Development status of rotary engine at Toyo Kogyo. [for general aviation aircraft

    NASA Technical Reports Server (NTRS)

    Yamamoto, K.

    1978-01-01

    Progress in the development of rotary engines which use a thermal reactor as the primary part of the exhaust emission control system is reviewed. Possibilities of further improvements in fuel economy of future rotary engines are indicated.

  12. Implementation of a robust hybrid rotary-translational vibration energy harvester for autonomous self-powered acceleration measurement

    NASA Astrophysics Data System (ADS)

    Payne, Owen R.; Vandewater, Luke A.; Ung, Chandarin; Moss, Scott D.

    2015-04-01

    In this paper, a self-powered wireless sensor node utilising ambient vibrations for power is described. The device consists of a vibration energy harvester, power management system, microcontroller, accelerometer, RF transmitter/receiver and external LED indicators. The vibration energy harvester is adapted from a previously reported hybrid rotary-translational device and uses a pair of copper coil transducers to convert the mechanical energy of a magnetic sphere into usable electricity. The device requires less than 0.8 mW of power to operate continuously in its present setup (with LED indicators off) while measuring acceleration at a sample rate of 200 Hz, with the power source providing 39.7 mW of power from 500 mg excitations at 5.5 Hz. When usable input energy is removed, the device will continue to transmit data for more than 5 minutes.

  13. Materials for Heated Head Automated Thermoplastic Tape Placement

    NASA Technical Reports Server (NTRS)

    Jensen, Brian J.; Kinney, Megan C.; Cano, Roberto J.; Grimsley, Brian W.

    2012-01-01

    NASA Langley Research Center (LaRC) is currently pursuing multiple paths to develop out of autoclave (OOA) polymeric composite materials and processes. Polymeric composite materials development includes the synthesis of new and/or modified thermosetting and thermoplastic matrix resins designed for specific OOA processes. OOA processes currently under investigation include vacuum bag only (VBO) prepreg/composite fabrication, resin transfer molding (RTM), vacuum assisted resin transfer molding (VARTM) and heated head automated thermoplastic tape placement (HHATP). This paper will discuss the NASA Langley HHATP facility and capabilities and recent work on characterizing thermoplastic tape quality and requirements for quality part production. Samples of three distinct versions of APC-2 (AS4/PEEK) thermoplastic dry tape were obtained from two materials vendors, TENCATE, Inc. and CYTEC Engineered Materials** (standard grade and an experimental batch). Random specimens were taken from each of these samples and subjected to photo-microscopy and surface profilometry. The CYTEC standard grade of APC-2 tape had the most voids and splits and the highest surface roughness and/or waviness. Since the APC-2 tape is composed of a thermoplastic matrix, it offers the flexibility of reprocessing to improve quality, and thereby improve final quality of HHATP laminates. Discussions will also include potential research areas and future work that is required to advance the state of the art in the HHATP process for composite fabrication.

  14. Comparison of near fusional vergence ranges with rotary prisms and with prism bars.

    PubMed

    Goss, David A; Becker, Emily

    2011-02-01

    Common methods for determination of fusional vergence ranges make use of rotary prisms in the phoropter or prism bars out of the phoropter. This study compared near fusional vergence ranges with rotary prisms with those with prism bars. Fifty young adults served as subjects. Odd-numbered subjects had rotary prism vergences performed before prism bar vergences. For even-numbered subjects, prism bar vergences were done first. Base-in (BI) vergences were done before base-out (BO) vergences with both rotary prisms and prism bars. A coefficient of agreement was calculated by multiplying the standard deviation of the individual subject differences between rotary prisms and prism bars by 1.96, to approximate the range within which the 2 tests would agree 95% of the time. The lowest coefficient of agreement was 7.3Δ for the BI recovery. The others were high, ranging from 15.4Δ for the BO recovery to 19.5Δ for the BO break. Fusional vergence ranges determined by prism bars out of the phoropter cannot be used interchangeably with those determined by phoropter rotary prisms for the purpose of follow-up on individual patients or for the purpose of comparison with norms. Copyright © 2010 American Optometric Association. Published by Elsevier Inc. All rights reserved.

  15. A new method of measurement of tension on a moving magnetic tape

    NASA Technical Reports Server (NTRS)

    Kurtinaytis, A. K.; Lauzhinskas, Y. S.

    1973-01-01

    The possibility of no-contact measurement of the tension on a moving magnetic tape, assuming the tape is uniform, is discussed. A scheme for calculation of the natural frequency of transverse vibrations of magnetic tape is shown. Mathematical models are developed to show the relationships of the parameters. The method is applicable to the analysis of accurate tape feed mechanisms design.

  16. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    DOEpatents

    Goyal, Amit

    2013-07-09

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  17. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    DOEpatents

    Goyal, Amit [Knoxville, TN

    2012-07-24

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  18. [Efficacy of the application of kinesio tape in patients with stroke].

    PubMed

    Ortiz-Ramirez, J; Perez-De la Cruz, S

    2017-02-16

    To review the effects achieved by the kinesio tape in patients with stroke in scientific studies published on date and to discuss these findings may be of interest to neurology. An exhaustive search in the main scientific databases using keywords such as kinesio tape, kinesiotaping, musculoskeletal tape, taping medical concept was carried out. Citations of selected articles and scientific papers published on the website of the Spanish Association of Neuromuscular Bandage were analyzed. Experimental, quasi-experimental, clinical trials and case studies published were used, without limit date, with therapeutical treatment purpose provide important results. Eight articles have met the inclusion criteria. There are eight studies that examine the effect on kinesio tape on lower limb, gait and balance in this kind of therapy, even upper limb and swallowing problems that these patients could present. The kinesio tape in neurological patients can be a complementary technique that empirically provides benefits. However, better methodological quality studies demonstrating the effects attributed to him are still needed.

  19. Recovery of recordings from heat damaged magnetic tapes

    NASA Technical Reports Server (NTRS)

    Melugin, J. F.; Obrien, D. E., III

    1973-01-01

    Damaged tapes can now be repaired at home as long as damage does not extend to layer-to-layer adhesion within tape roll. Splice repaired section into good roll or cassette for copying. Every effort should be made to complete copying on first run, because fidelity in repaired section deteriorates with each repetition.

  20. Multi-fuel rotary engine for general aviation aircraft

    NASA Technical Reports Server (NTRS)

    Jones, C.; Ellis, D. R.; Meng, P. R.

    1983-01-01

    Design studies of advanced multifuel general aviation and commuter aircraft rotary stratified charge engines are summarized. Conceptual design studies were performed at two levels of technology, on advanced general aviation engines sized to provide 186/250 shaft kW/hp under cruise conditions at 7620 (25000 m/ft) altitude. A follow on study extended the results to larger (2500 hp max.) engine sizes suitable for applications such as commuter transports and helicopters. The study engine designs were derived from relevant engine development background including both prior and recent engine test results using direct injected unthrottled rotary engine technology. Aircraft studies, using these resultant growth engines, define anticipated system effects of the performance and power density improvements for both single engine and twin engine airplanes. The calculated results indicate superior system performance and 27 to 33 percent fuel economy improvement for the rotary engine airplanes as compared to equivalent airframe concept designs with current baseline engines. The research and technology activities required to attain the projected engine performance levels are also discussed.

  1. Multi-fuel rotary engine for general aviation aircraft

    NASA Technical Reports Server (NTRS)

    Jones, C.; Ellis, D. R.; Meng, P. R.

    1983-01-01

    Design studies of advanced multifuel general aviation and commuter aircraft rotary stratified charge engines are summarized. Conceptual design studies were performed at two levels of technology, an advanced general aviation engines sized to provide 186/250 shaft kW/hp under cruise conditions at 7620 (25,000 m/ft) altitude. A follow on study extended the results to larger (2500 hp max.) engine sizes suitable for applications such as commuter transports and helicopters. The study engine designs were derived from relevant engine development background including both prior and recent engine test results using direct injected unthrottled rotary engine technology. Aircraft studies, using these resultant growth engines, define anticipated system effects of the performance and power density improvements for both single engine and twin engine airplanes. The calculated results indicate superior system performance and 27 to 33 percent fuel economy improvement for the rotary engine airplanes as compared to equivalent airframe concept designs with current baseline engines. The research and technology activities required to attain the projected engine performance levels are also discussed. Previously announced in STAR as N83-18910

  2. Feasibility model of a high reliability five-year tape transport, volume 2

    NASA Technical Reports Server (NTRS)

    Eshleman, R. L.; Meyers, A. P.; Davidson, W. A.; Gortowski, R. C.; Anderson, M. E.

    1973-01-01

    Analysis of the design features of the modularized tape transport renders a life expectancy in excess of five years. Tests performed on the tape transport were directed toward determining its performance capability. These tests revealed that the tape jitter and skew are in the range achieved by high quality digital tape transports. Guidance of the tape in the lateral sense by the use of the two hybrid crowned rollers proved to be excellent. Tracking was maintained within less than one thousandth inch (approximately 2 micrometers). The guidance capability demonstrated makes possible the achievement of the performance objective of 7.2 x 10 to the 9th power storage capability employing 1500 ft. of one inch wide tape with a packing density of 5,000 bits per inch per track on 80 tracks. Also, the machine showed excellent characteristics operating over a wide range of tape speeds. The basic design concept lends itself to growth and adaptation to a wide range of recorder requirements.

  3. Kinesiology tape mediates soccer-simulated and local peroneal fatigue in soccer players.

    PubMed

    Farquharson, Claire; Greig, Matt

    2017-01-01

    To investigate the efficacy of kinesiology taping in mediating the influence of fatigue on ankle sprain risk, 12 male soccer players completed single-leg dynamic balance trials pre- and post-exercise (soccer-specific protocol, isokinetic ankle inversion/eversion protocol) in each of three counter-balanced taping conditions (no tape, zinc oxide tape ZO, kinesiology tape KT). Balance was quantified as the overall stability index (OSI) and directional stability indices of platform deflection. Soccer-specific fatigue only increased OSI in the no tape condition (p = 0.03), with ZO and KT trials negating a fatigue affect. Localized fatigue increased OSI in the no tape (p = 0.01) and ZO (p = 0.05) trials, with no increase in the KT trial. A similar pattern was observed in medio-lateral and anterio-posterior balance indices. KT mediates soccer-simulated and local peroneal fatigue, with practical implications for epidemiological observations of increased injury risk during the latter stages of match play.

  4. Software Computes Tape-Casting Parameters

    NASA Technical Reports Server (NTRS)

    deGroh, Henry C., III

    2003-01-01

    Tcast2 is a FORTRAN computer program that accelerates the setup of a process in which a slurry containing metal particles and a polymeric binder is cast, to a thickness regulated by a doctor blade, onto fibers wound on a rotating drum to make a green precursor of a metal-matrix/fiber composite tape. Before Tcast2, setup parameters were determined by trial and error in time-consuming multiple iterations of the process. In Tcast2, the fiber architecture in the final composite is expressed in terms of the lateral distance between fibers and the thickness-wise distance between fibers in adjacent plies. The lateral distance is controlled via the manner of winding. The interply spacing is controlled via the characteristics of the slurry and the doctor-blade height. When a new combination of fibers and slurry is first cast and dried to a green tape, the shrinkage from the wet to the green condition and a few other key parameters of the green tape are measured. These parameters are provided as input to Tcast2, which uses them to compute the doctor-blade height and fiber spacings needed to obtain the desired fiber architecture and fiber volume fraction in the final composite.

  5. Mechanical design of a rotary balance system for NASA. Langley Research Center's vertical spin tunnel

    NASA Technical Reports Server (NTRS)

    Allred, J. W.; Fleck, V. J.

    1992-01-01

    A new lightweight Rotary Balance System is presently being fabricated and installed as part of a major upgrade to the existing 20 Foot Vertical Spin Tunnel. This upgrade to improve model testing productivity of the only free spinning vertical wind tunnel includes a modern fan/drive and tunnel control system, an updated video recording system, and the new rotary balance system. The rotary balance is a mechanical apparatus which enables the measurement of aerodynamic force and moment data under spinning conditions (100 rpm). This data is used in spin analysis and is vital to the implementation of large amplitude maneuvering simulations required for all new high performance aircraft. The new rotary balance system described in this report will permit greater test efficiency and improved data accuracy. Rotary Balance testing with the model enclosed in a tare bag can also be performed to obtain resulting model forces from the spinning operation. The rotary balance system will be stored against the tunnel sidewall during free flight model testing.

  6. Contact Analog/Compressed Symbology Heading Tape Assessment

    NASA Technical Reports Server (NTRS)

    Shively, R. Jay; Atencio, Adolph; Turpin, Terry; Dowell, Susan

    2002-01-01

    A simulation assessed the performance, handling qualities and workload associated with a contact-analog, world-referenced heading tape as implemented on the Comanche Helmet Integrated Display Sight System (HIDSS) when compared with a screen-fixed, compressed heading tape. Six pilots, four active duty Army Aviators and two civilians flew three ADS-33 maneuvers and a traffic pattern in the Ames Vertical Motion Simulation facility. Small, but statistically significant advantages were found for the compressed symbology for handling qualities, workload, and some of the performance measures. It should be noted however that the level of performance and handling qualities for both symbology sets fell within the acceptable tolerance levels. Both symbology sets yield satisfactory handling qualities and performance in velocity stabilization mode and adequate handling qualities in the automatic flight control mode. Pilot comments about the contact analog symbology highlighted the lack of useful rate of change information in the heading tape and "blurring" due to the rapid movement of the heading tape. These issues warrant further study. Care must be taken in interpreting the operational significance of these results. The symbology sets yielded categorically similar data, i.e., acceptable handling qualities and adequate performance, so while the results point to the need for further study, their operational significance has yet to be determined.

  7. A Thermoelectric Waste-Heat-Recovery System for Portland Cement Rotary Kilns

    NASA Astrophysics Data System (ADS)

    Luo, Qi; Li, Peng; Cai, Lanlan; Zhou, Pingwang; Tang, Di; Zhai, Pengcheng; Zhang, Qingjie

    2015-06-01

    Portland cement is produced by one of the most energy-intensive industrial processes. Energy consumption in the manufacture of Portland cement is approximately 110-120 kWh ton-1. The cement rotary kiln is the crucial equipment used for cement production. Approximately 10-15% of the energy consumed in production of the cement clinker is directly dissipated into the atmosphere through the external surface of the rotary kiln. Innovative technology for energy conservation is urgently needed by the cement industry. In this paper we propose a novel thermoelectric waste-heat-recovery system to reduce heat losses from cement rotary kilns. This system is configured as an array of thermoelectric generation units arranged longitudinally on a secondary shell coaxial with the rotary kiln. A mathematical model was developed for estimation of the performance of waste heat recovery. Discussions mainly focus on electricity generation and energy saving, taking a Φ4.8 × 72 m cement rotary kiln as an example. Results show that the Bi2Te3-PbTe hybrid thermoelectric waste-heat-recovery system can generate approximately 211 kW electrical power while saving 3283 kW energy. Compared with the kiln without the thermoelectric recovery system, the kiln with the system can recover more than 32.85% of the energy that used to be lost as waste heat through the kiln surface.

  8. Rotary's PolioPlus Program: Lessons Learned, Transition Planning, and Legacy.

    PubMed

    Sever, John L; McGovern, Michael; Scott, Robert; Pandak, Carol; Edwards, Amy; Goodstone, David

    2017-07-01

    Hundreds of thousands of Rotary volunteers have provided support for polio eradication activities and continue to this day by making financial contributions to the Rotary PolioPlus program, participating in national immunization days, assisting with surveillance, working on local, national, and international advocacy programs for polio eradication, assisting at immunization posts and clinics, and mobilizing their communities for immunization activities (including poliovirus and other vaccines) and other health benefits. Rotary has contributed more than $1.61 billion for the global eradication of polio and has committed to provide an additional $35 million each year until 2018 (all dollar amounts represent US dollars). Its unwavering commitment to eradicate polio has been vital to the success of the program. Rotary is providing additional support for routine immunization and healthcare. When polio is finally gone, we will have the knowledge from the lessons learned with PolioPlus, such as the value of direct involvement by local Rotarians, the program for emergency funding, innovative tactics, and additional approaches for tackling other global issues, even those beyond public health. Rotary has already transitioned its grants program to include 6 areas of focus: disease prevention and treatment, water and sanitation, maternal and child health, basic education and literacy, economic and community development, and peace and conflict prevention/resolution. Funding for these grants in 2015-2016 was $71 million. The legacy of the polio program will be the complete eradication of poliovirus and the elimination of polio for all time. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  9. Mirror-touch and ticker tape experiences in synesthesia

    PubMed Central

    Chun, Charlotte A.; Hupé, Jean-Michel

    2013-01-01

    A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia's connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person's arm being stroked can evoke physical touch sensation on one's own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker's mouth. To explore synesthesia's associations with these phenomena, a diverse group (n = 3743) was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1017 eligible respondents, synesthetes (across all subtypes) reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However, effect sizes were small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2–4%) and sequence-space synesthesia (9–14%). Within synesthesia, grapheme-personification, also called ordinal-linguistic personification (OLP) was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect sizes. PMID

  10. An Experimental Investigation of Damaged Arresting Gear Tapes for the Langley Aircraft Landing Dynamics Facility

    NASA Technical Reports Server (NTRS)

    Mason, Angela J.

    1999-01-01

    An experimental investigation was performed on damaged arresting gear tapes at the Langley Aircraft Landing Dynamics Facility. The arrestment system uses five pairs of tapes to bring the test carriage to a halt. The procedure used to determine when to replace the tapes consists of a close evaluation of each of the 10 tapes after each run. During this evaluation, each tape is examined thoroughly and any damage observed on the tape is recorded. If the damaged tape does not pass the inspection, the tape is replaced with a new one. For the past 13 years, the most commonly seen damage types are edge fray damage and transverse damage. Tests were conducted to determine the maximum tensile strength of a damaged arresting gear tape specimen. The data indicate that tapes exhibiting transverse damage can withstand higher loads than tapes with edge fray damage.

  11. Comparison between rotary and manual instrumentation in primary teeth.

    PubMed

    Crespo, S; Cortes, O; Garcia, C; Perez, L

    2008-01-01

    The aim of this study was to compare the efficiency in both, preparation time and root canal shape, when using the Nickel Titanium (Ni-Ti) rotary and K-Files hand instrumentation on root canal preparation of single rooted primary teeth. Sixty single rooted primary teeth were selected and divided into two equal groups: Group (I) 30 teeth instrumented with manual K-files and group (II) 30 teeth instrumented with Ni-Ti rotary files (ProFile 0.04). Instrumentation times were calculated and root canal impressions were taken with light bodied silicone in order to evaluate the shape. The data was analyzed with SPSS program using the t-test and the Chi-square test to compare their means. The preparation time with group (I) K-files was significantly higher than in group (II) rotary files (ProFile 0.04), with a p= .005. The ProFile system showed a significantly more favorable canal taper when compared to the K-files system (P= .002). The use of rotary files in primary teeth has several advantages when compared with manual K files: the efficiency in both, preparation time and root canal shape. 1. A decreased working time, that helps maintain patient cooperation by diminishing the potential for tiredness. 2. The shape of the root canal is more conical, favoring a higher quality of the root canal filling, and increasing clinical success.

  12. [In vitro comparison of root canal preparation with step-back technique and GT rotary file--a nickel-titanium engine driven rotary instrument system].

    PubMed

    Krajczár, Károly; Tóth, Vilmos; Nyárády, Zoltán; Szabó, Gyula

    2005-06-01

    The aim of the authors' study was to compare the remaining root canal wall thickness and the preparation time of root canals, prepared either with step-back technique, or with GT Rotary File, an engine driven nickel-titanium rotary instrument system. Twenty extracted molars were decoronated. Teeth were divided in two groups. In Group 1 root canals were prepared with step-back technique. In Group 2 GT Rotary File System was utilized. Preoperative vestibulo-oral X-ray pictures were taken from all teeth with radiovisiograph (RVG). The final preparations at the mesiobuccal canals (MB) were performed with size #30 and palatinal/distal canals with size #40 instruments. Postoperative RVG pictures were taken ensuring the preoperative positioning. The working time was measured in seconds during each preparation. The authors also assessed the remaining root canal wall thickness at 3, 6 and 9 mm from the radiological apex, comparing the width of the canal walls of the vestibulo-oral projections on pre- and postoperative RVG pictures both mesially and buccally. The ratios of the residual and preoperative root canal wall thickness were calculated and compared. The largest difference was found at the MB canals of the coronal and middle third level of the root, measured on the distal canal wall. The ratio of the remaining dentin wall thickness at the coronal and the middle level in the case of step-back preparation was 0.605 and 0.754, and 0.824 and 0.895 in the cases of GT files respectively. The preparation time needed for GT Rotary File System was altogether 68.7% (MB) and 52.5% (D/P canals) of corresponding step-back preparation times. The use of GT Rotary File with comparison of standard step-back method resulted in a shortened preparation time and excessive damage of the coronal part of the root canal could be avoided.

  13. 21 CFR 878.4730 - Surgical skin degreaser or adhesive tape solvent.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical skin degreaser or adhesive tape solvent... Surgical skin degreaser or adhesive tape solvent. (a) Identification. A surgical skin degreaser or an... dissolve surface skin oil or adhesive tape. (b) Classification. Class I (general controls). The device is...

  14. Comparative Study of Piezoelectric and Rotary Osteotomy Technique for Third Molar Impaction.

    PubMed

    Basheer, Sulphi A; Govind, R Jay; Daniel, Augustine; Sam, George; Adarsh, V J; Rao, Akshatha

    2017-01-01

    Bone removal is necessary for extracting the third molars that are erupted, partially erupted, and/or impacted in bone. Hence, it is necessary to choose a surgical method or instruments that conform to anatomic landmarks and are based on physiological principles. Many authors have reported injuries to the adjacent tooth, especially the distal part of periodontium after removal of second molar. Hence, the present study was undertaken to assess and compare the surgical and postsurgi-cal outcomes of third molar removal using piezoelectric surgery and rotary bur. A total of 30 healthy adult individuals who were in need of prophylactic removal of impacted man-dibular third molar tooth with ideal condition were included for the study. Individuals were divided randomly into study groups of 15 each, so that the difficulty of surgery will be the same in both the groups. Group I - piezoelectric osteotomy technique and group II - rotary osteotomy technique. The rotary device consists of a hand piece and a rotary speed ranging around 35,000 rpm was used. The piezoelectric device consists of a hand piece, and a frequency of 25 to 29 kHz with a microvibration of 60 to 200 mm/sec was used with a boosted working mode. Data were analyzed using unpaired t-test and qualitative data were analyzed using Fischer's exact test. The average age of the study subjects in the piezo-surgery group and rotary group was 28.40 ± 2.69 and 30.06 ± 3.15 years respectively. The time taken for removal of impacted tooth by rotary bur was less than that by piezoelectric device, which was significant statistically (p < 0.05). Until the 4th postoperative day, severity of pain experienced was more in the rotary group, which was statistically significant (p < 0.005). Mouth opening was significantly better in the piezoelectric group as compared with rotary bur until the 7th postoperative day. The piezosurgery method reduces postoperative pain, trismus, and swelling. Also, it may play an important role in

  15. Comparison of structural performance of one- and two-bay rotary joints for truss applications

    NASA Technical Reports Server (NTRS)

    Vail, J. Douglas; Lake, Mark S.

    1991-01-01

    The structural performance of one- and two-bay large-diameter discrete-bearing rotary joints was addressed for application to truss-beam structures such as the Space Station Freedom. Finite element analyses are performed to determine values for rotary joint parameters that give the same bending vibration frequency as the parent truss beam. The structural masses and maximum internal loads of these joints are compared to determine their relative structural efficiency. Results indicate that no significant difference exists in the masse of one- and two-bay rotary joints. This conclusion is reinforced with closed-form calculations of rotary joint structural efficiency in extension. Also, transition truss-member loads are higher in the one-bay rotary joint. However, because of the increased buckling strength of these members, the external load-carrying capability of the one-bay concept is higher than that of the two-bay concept.

  16. Effects of Kinesio taping and exercise on forward head posture.

    PubMed

    Shih, Hsu-Sheng; Chen, Shu-Shi; Cheng, Su-Chun; Chang, Hsun-Wen; Wu, Pei-Rong; Yang, Jin-Shiou; Lee, Yi-Shuang; Tsou, Jui-Yi

    2017-01-01

    Little is known about the effects of Kinesio taping and therapeutic exercise on correcting forward head posture. To compare Kinesio taping versus therapeutic exercise for forward head posture on static posture, dynamic mobility and functional outcomes. Sixty subjects (31 women, 29 men) with forward head postures participated in this study. They were randomly assigned to either one of the three groups: (1) exercise group (n = 20), (2) taping group (n = 20), and (3) control groups (n = 20). The horizontal forward displacement (HFD) between ear lobe and acromion process, upper cervical and lower cervical angle (UCA, LCA), active range of motion (AROM) of cervical spine, and neck disability index (NDI) were measured before and after a 5-week intervention, and a 2-week follow-up. Data were analyzed by means of a mixed design repeated-measures ANOVA. Both taping and exercise groups showed significant improvements in HFD compared with the control group at post-treatment and follow-up. Compared with the control group, the exercise group exhibited significant improvements in the LCA and the side bending AROM at post-treatment. Both Kinesio taping and therapeutic exercise improve forward head posture after intervention and a 2-week follow-up. The effectiveness of therapeutic exercise is better than taping.

  17. Kinesio Taping effects on knee extension force among soccer players.

    PubMed

    Serra, Maysa V G B; Vieira, Edgar R; Brunt, Denis; Goethel, Márcio F; Gonçalves, Mauro; Quemelo, Paulo R V

    2015-01-01

    Kinesio Taping (KT) is widely used, however the effects of KT on muscle activation and force are contradictory. To evaluate the effects of KT on knee extension force in soccer players. This is a clinical trial study design. Thirty-four subjects performed two maximal isometric voluntary contractions of the lower limbs pre, immediately post, and 24 hours after tape application on the lower limbs. Both lower limbs were taped, using K-Tape and 3M Micropore tape randomly on the right and left thighs of the participants. Isometric knee extension force was measured for dominant side using a strain gauge. The following variables were assessed: peak force, time to peak force, rate of force development until peak force, time to peak rate of force development, and 200 ms pulse. There were no statistically significant differences in the variables assessed between KT and Micropore conditions (F=0.645, p=0.666) or among testing sessions (pre, post, and 24h after) (F=0.528, p=0.868), and there was no statistical significance (F=0.271, p=0.986) for interaction between tape conditions and testing session. KT did not affect the force-related measures assessed immediately and 24 hours after the KT application compared with Micropore application, during maximal isometric voluntary knee extension.

  18. Effects of kinesio tape to reduce hand edema in acute stroke.

    PubMed

    Bell, Alison; Muller, Melissa

    2013-01-01

    The purpose of the study was to evaluate the effi cacy of Kinesio Tape (Kinesio USA, Albequerque, NM) for reducing hand edema in individuals with hemiplegia post stroke. Seventeen individuals who experienced acute stroke were screened for visual signs of edema and were randomly assigned to experimental and control groups. The experimental group received Kinesio Tape that was applied to hand and forearm for 6 days in combination with standard therapy; the control group received standard therapy. Blinded raters assessed edema reduction via circumferential measurements. Application of Kinesio Tape did not result in statistically signifi cant reduction in edema. Large and medium effect sizes were seen for edema reduction at the metacarpophalangeal and wrist joints, respectively, with Kinesio Tape. Further research is warranted to investigate the utility of Kinesio Tape in edema reduction.

  19. Induction Bonding of Prepreg Tape and Titanium Foil

    NASA Technical Reports Server (NTRS)

    Messier, Bernadette C.; Hinkley, Jeffrey A.; Johnston, Norman J.

    1998-01-01

    Hybrid structural laminates made of titanium foil and carbon fiber reinforced polymer composite offer a potential for improved performance in aircraft structural applications. To obtain information needed for the automated fabrication of hybrid laminates, a series of bench scale tests were conducted of the magnetic induction bonding of titanium foil and thermoplastic prepreg tape. Foil and prepreg specimens were placed in the gap of a toroid magnet mounted in a bench press. Several magnet power supplies were used to study power at levels from 0.5 to 1.75 kW and frequencies from 50 to 120 kHz. Sol-gel surface-treated titanium foil, 0.0125 cm thick, and PIXA/IM7 prepreg tape were used in several lay-up configurations. Data were obtained on wedge peel bond strength, heating rate, and temperature ramp over a range of magnet power levels and frequencies at different "power-on" times for several magnet gap dimensions. These data will be utilized in assessing the potential for automated processing. Peel strengths of foil-tape bonds depended on the maximum temperature reached during heating and on the applied pressure. Maximum peel strengths were achieved at 1.25kW and 8OkHz. Induction heating of the foil appears to be capable of good bonding up to 10 plies of tape. Heat transfer calculations indicate that a 20-40 C temperature difference exists across the tape thickness during heat-up.

  20. Report of the Tape Recorder Action Plan Committee, 21 March 1972

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A NASA/AF Tape Recorder Action Plan Committee was formed in January 1972 to investigate tape recorder problems and to recommend an action plan to NASA management. The committee collected data on tape recorder failure history, pinpointed problem areas, discussed needed technical and management changes, and proposed an action plan for the recommended approaches.

  1. Interpretation of the human skin biotribological behaviour after tape stripping.

    PubMed

    Pailler-Mattei, C; Guerret-Piécourt, C; Zahouani, H; Nicoli, S

    2011-07-06

    The present study deals with the modification of the human skin biotribological behaviour after tape stripping. The tape-stripping procedure consists in the sequential application and removal of adhesive tapes on the skin surface in order to remove stratum corneum (SC) layers, which electrically charges the skin surface. The skin electric charges generated by tape stripping highly change the skin friction behaviour by increasing the adhesion component of the skin friction coefficient. It has been proposed to rewrite the friction adhesion component as the sum of two terms: the first classical adhesion term depending on the intrinsic shear strength, τ(0), and the second term depending on the electric shear strength, τ(elec). The experimental results allowed to estimate a numerical value of the electric shear strength τ(elec). Moreover, a plan capacitor model with a dielectric material inside was used to modelize the experimental system. This physical model permitted to evaluate the friction electric force and the electric shear strength values to calculate the skin friction coefficient after the tape stripping. The comparison between the experimental and the theoretical value of the skin friction coefficient after the tape stripping has shown the importance of the electric charges on skin biotribological behaviour. The static electric charges produced by tape stripping on the skin surface are probably able to highly modify the interaction of formulations with the skin surface and their spreading properties. This phenomenon, generally overlooked, should be taken into consideration as it could be involved in alteration of drug absorption.

  2. Interpretation of the human skin biotribological behaviour after tape stripping

    PubMed Central

    Pailler-Mattei, C.; Guerret-Piécourt, C.; Zahouani, H.; Nicoli, S.

    2011-01-01

    The present study deals with the modification of the human skin biotribological behaviour after tape stripping. The tape-stripping procedure consists in the sequential application and removal of adhesive tapes on the skin surface in order to remove stratum corneum (SC) layers, which electrically charges the skin surface. The skin electric charges generated by tape stripping highly change the skin friction behaviour by increasing the adhesion component of the skin friction coefficient. It has been proposed to rewrite the friction adhesion component as the sum of two terms: the first classical adhesion term depending on the intrinsic shear strength, τ0, and the second term depending on the electric shear strength, τelec. The experimental results allowed to estimate a numerical value of the electric shear strength τelec. Moreover, a plan capacitor model with a dielectric material inside was used to modelize the experimental system. This physical model permitted to evaluate the friction electric force and the electric shear strength values to calculate the skin friction coefficient after the tape stripping. The comparison between the experimental and the theoretical value of the skin friction coefficient after the tape stripping has shown the importance of the electric charges on skin biotribological behaviour. The static electric charges produced by tape stripping on the skin surface are probably able to highly modify the interaction of formulations with the skin surface and their spreading properties. This phenomenon, generally overlooked, should be taken into consideration as it could be involved in alteration of drug absorption. PMID:21227961

  3. Compilation of fatigue, fatigue-crack propagation, and fracture data for 2024 and 7075 aluminum, Ti-6Al-4V titanium, and 300M steel. Volume 1: Description of data and data storage on magnetic tape. Volume 2: Data tape (7-track magnetic tape)

    NASA Technical Reports Server (NTRS)

    Rice, R. C.; Reynolds, J. L.

    1976-01-01

    Fatigue, fatigue-crack-propagation, and fracture data compiled and stored on magnetic tape are documented. Data for 202 and 7075 aluminum alloys, Ti-6Al-4V titanium alloy, and 300M steel are included in the compilation. Approximately 4,500 fatigue, 6,500 fatigue-crack-propagation, and 1,500 fracture data points are stored on magnetic tape. Descriptions of the data, an index to the data on the magnetic tape, information on data storage format on the tape, a listing of all data source references, and abstracts of other pertinent test information from each data source reference are included.

  4. An efficient, modular and simple tape archiving solution for LHC Run-3

    NASA Astrophysics Data System (ADS)

    Murray, S.; Bahyl, V.; Cancio, G.; Cano, E.; Kotlyar, V.; Kruse, D. F.; Leduc, J.

    2017-10-01

    The IT Storage group at CERN develops the software responsible for archiving to tape the custodial copy of the physics data generated by the LHC experiments. Physics run 3 will start in 2021 and will introduce two major challenges for which the tape archive software must be evolved. Firstly the software will need to make more efficient use of tape drives in order to sustain the predicted data rate of 150 petabytes per year as opposed to the current 50 petabytes per year. Secondly the software will need to be seamlessly integrated with EOS, which has become the de facto disk storage system provided by the IT Storage group for physics data. The tape storage software for LHC physics run 3 is code named CTA (the CERN Tape Archive). This paper describes how CTA will introduce a pre-emptive drive scheduler to use tape drives more efficiently, will encapsulate all tape software into a single module that will sit behind one or more EOS systems, and will be simpler by dropping support for obsolete backwards compatibility.

  5. Tools for applying lead tape to flat conductor cabling for chemical stripping

    NASA Technical Reports Server (NTRS)

    Angele, W.

    1969-01-01

    Two tools facilitate chemical stripping of insulation on flat conductor cabling. A tape pressing tool and a taping fixture apply adhesive lead tape with the proper amount of pressure to protect the remaining insulation from the chemical stripping solution.

  6. A Survey on Nickel Titanium Rotary Instruments and their Usage Techniques by Endodontists in India.

    PubMed

    Patil, Thimmanagowda N; Saraf, Prahlad A; Penukonda, Raghavendra; Vanaki, Sneha S; Kamatagi, Laxmikant

    2017-05-01

    The preference and usage of nickel titanium rotary instruments varies from individual to individual based on their technique, experience with the rotary systems and the clinical situation. Very limited information is available to explain the adoption of changing concepts with respect to nickel titanium rotary instruments pertaining to the endodontists in India. The aim of this study was to conduct a questionnaire survey to acquire the knowledge concerning different NiTi rotary instruments and their usage techniques by endodontists in India. A Survey questionnaire was designed which consisted of 32 questions regarding designation, demographics, experience with rotary instruments, usage of different file systems, usage techniques, frequency of reuse, occurrence of file fracture, reasons and their management was distributed by hand in the national postgraduate convention and also disseminated via electronic medium to 400 and 600 endodontists respectively. Information was collected from each individual to gain insight into the experiences and beliefs of endodontists concerning the new endodontic technology of rotary NiTi instrumentation based on their clinical experience with the rotary systems. The questions were designed to ascertain the problems, patterns of use and to identify areas of perceived or potential concern regarding the rotary instruments and the data acquired was statistically evaluated using Fisher's-exact test and the Chi-Square test. Overall 63.8% (638) endodontists responded. ProTaper was one of the most commonly used file system followed by M two and ProTaper Next. There was a significant co relation between the years of experience and the file re use frequency, preparation technique, file separation, management of file separation. A large number of Endodontists prefer to reuse the rotary NiTi instruments. As there was an increase in the experience, the incidence of file separation reduced with increasing number of re use frequency and with

  7. Structural characterization and magnetic properties of L10-MnAl films grown on different underlayers by molecular beam epitaxy

    NASA Astrophysics Data System (ADS)

    Takata, Fumiya; Gushi, Toshiki; Anzai, Akihito; Toko, Kaoru; Suemasu, Takashi

    2018-03-01

    We grow MnAl films on different underlayers by molecular beam epitaxy (MBE), and investigate their structural and magnetic properties. L10-ordered MnAl films were successfully grown both on an MgO(0 0 1) single-crystalline substrate and on an Mn4N(0 0 1) buffer layer formed on MgO(0 0 1) and SrTiO3(0 0 1) substrates. For the MgO substrate, post rapid thermal annealing (RTA) drastically improved the crystalline quality and the degree of L10-ordering, whereas no improvement in the crystallinity was achieved by altering the substrate temperature (TS) during MBE growth. However, high-quality L10-MnAl films were formed on the Mn4N buffer layer by simply varying TS. Structural analysis using X-ray diffraction showed MnAl on an MgO substrate had a cubic structure whereas MnAl on the Mn4N buffer had a tetragonal structure. This difference in crystal structure affected the magnetic properties of the MnAl films. The uniaxial magnetic anisotropy constant (Ku) was drastically improved by inserting an Mn4N buffer layer. We achieved a perpendicular magnetic anisotropy of Ku = 5.0 ± 0.7 Merg/cm3 for MnAl/Mn4N film on MgO and 6.0 ± 0.2 Merg/cm3 on STO. These results suggest that Mn4N has potential as an underlayer for L10-MnAl.

  8. Influence of oscillating and rotary cutting instruments with electric and turbine handpieces on tooth preparation surfaces.

    PubMed

    Geminiani, Alessandro; Abdel-Azim, Tamer; Ercoli, Carlo; Feng, Changyong; Meirelles, Luiz; Massironi, Domenico

    2014-07-01

    Rotary and nonrotary cutting instruments are used to produce specific characteristics on the axial and marginal surfaces of teeth being prepared for fixed restorations. Oscillating instruments have been suggested for tooth preparation, but no comparative surface roughness data are available. To compare the surface roughness of simulated tooth preparations produced by oscillating instruments versus rotary cutting instruments with turbine and electric handpieces. Different grit rotary cutting instruments were used to prepare Macor specimens (n=36) with 2 handpieces. The surface roughness obtained with rotary cutting instruments was compared with that produced by oscillating cutting instruments. The instruments used were as follows: coarse, then fine-grit rotary cutting instruments with a turbine (group CFT) or an electric handpiece (group CFE); coarse, then medium-grit rotary cutting instruments with a turbine (group CMT) or an electric handpiece (group CME); coarse-grit rotary cutting instruments with a turbine handpiece and oscillating instruments at a low-power (group CSL) or high-power setting (group CSH). A custom testing apparatus was used to test all instruments. The average roughness was measured for each specimen with a 3-dimensional optical surface profiler and compared with 1-way ANOVA and the Tukey honestly significant difference post hoc test for multiple comparisons (α=.05). Oscillating cutting instruments produced surface roughness values similar to those produced by similar grit rotary cutting instruments with a turbine handpiece. The electric handpiece produced smoother surfaces than the turbine regardless of rotary cutting instrument grit. Rotary cutting instruments with electric handpieces produced the smoothest surface, whereas the same instruments used with a turbine and oscillating instruments achieved similar surface roughness. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights

  9. Generation and physical characteristics of the ERTS MSS system corrected computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1973-01-01

    The generation and format are discussed of the ERTS system corrected multispectral scanner computer compatible tapes. The discussion includes spacecraft sensors, scene characteristics, data transmission, and conversion of data to computer compatible tapes at the NASA Data Processing Facility. Geometeric and radiometric corrections, tape formats, and the physical characteristics of the tapes are also included.

  10. An experimental study of the putative mechanism of a synthetic autonomous rotary DNA nanomotor

    NASA Astrophysics Data System (ADS)

    Dunn, K. E.; Leake, M. C.; Wollman, A. J. M.; Trefzer, M. A.; Johnson, S.; Tyrrell, A. M.

    2017-03-01

    DNA has been used to construct a wide variety of nanoscale molecular devices. Inspiration for such synthetic molecular machines is frequently drawn from protein motors, which are naturally occurring and ubiquitous. However, despite the fact that rotary motors such as ATP synthase and the bacterial flagellar motor play extremely important roles in nature, very few rotary devices have been constructed using DNA. This paper describes an experimental study of the putative mechanism of a rotary DNA nanomotor, which is based on strand displacement, the phenomenon that powers many synthetic linear DNA motors. Unlike other examples of rotary DNA machines, the device described here is designed to be capable of autonomous operation after it is triggered. The experimental results are consistent with operation of the motor as expected, and future work on an enhanced motor design may allow rotation to be observed at the single-molecule level. The rotary motor concept presented here has potential applications in molecular processing, DNA computing, biosensing and photonics.

  11. The effective resistance between twisted superconducting filaments in tapes

    NASA Astrophysics Data System (ADS)

    Takács, S.; Iwakuma, M.; Funaki, K.

    2001-05-01

    We consider two mechanisms, which influence the effective resistance between crossing strands on flat cables or filaments in twisted tapes. The one-layer classical Rutherford-type cable and the tapes with twisted BSCCO filaments in silver matrix are taken as analogous cases. The amount of the matrix between strands or filaments increases the effective conductance compared with the direct current paths (determined by the touching area of the filaments). The increase factor is about two and can easily be suppressed by other effects, like the contact resistance between the superconductor and the matrix. The second mechanism is due to the existence of induced voltage between any points of crossing filaments. This leads to an additional effective conductance, proportional to the square of the total number of filaments. Both effects are not very important for isotropic superconductors, but due to the strong anisotropy of critical parameters they can dominate for high temperature superconductors. The first one may partially compensate the influence of the usually weaker critical current density perpendicular to the tape. The contribution due to the second effect can explain the higher resistivity of the matrix in BSCCO tapes compared with pure silver. It seems that to obtain low AC coupling losses in BSCCO tapes, structures with small filament number are required.

  12. Structure of the vacuolar H+-ATPase rotary motor reveals new mechanistic insights.

    PubMed

    Rawson, Shaun; Phillips, Clair; Huss, Markus; Tiburcy, Felix; Wieczorek, Helmut; Trinick, John; Harrison, Michael A; Muench, Stephen P

    2015-03-03

    Vacuolar H(+)-ATPases are multisubunit complexes that operate with rotary mechanics and are essential for membrane proton transport throughout eukaryotes. Here we report a ∼ 1 nm resolution reconstruction of a V-ATPase in a different conformational state from that previously reported for a lower-resolution yeast model. The stator network of the V-ATPase (and by implication that of other rotary ATPases) does not change conformation in different catalytic states, and hence must be relatively rigid. We also demonstrate that a conserved bearing in the catalytic domain is electrostatic, contributing to the extraordinarily high efficiency of rotary ATPases. Analysis of the rotor axle/membrane pump interface suggests how rotary ATPases accommodate different c ring stoichiometries while maintaining high efficiency. The model provides evidence for a half channel in the proton pump, supporting theoretical models of ion translocation. Our refined model therefore provides new insights into the structure and mechanics of the V-ATPases. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Surreptitious Taping: The Arguments for and the Ethics against.

    ERIC Educational Resources Information Center

    Cooper, Thomas W.

    Much discussion within media ethics has focused on the acceptability of surreptitious tape recording of news sources by media professionals. The most common legal and social arguments supporting secret taping assert that recorders "hear" and "remember" better, are expedient and practical, protect against libel suits, provide…

  14. Root canal shaping with manual stainless steel files and rotary Ni-Ti files performed by students.

    PubMed

    Sonntag, D; Guntermann, A; Kim, S K; Stachniss, V

    2003-04-01

    To investigate root canal shaping with manual stainless steel files and rotary Ni-Ti files by students. Two hundred and ten simulated root canals with the same geometrical shape and size in acrylic resin blocks were prepared by 21 undergraduate dental students with manual stainless steel files using a stepback technique or with rotary Ni-Ti files in crown-down technique. Preparation length, canal shape, incidence of fracture and preparation time were investigated. Zips and elbows occurred significantly (P < 0.001) less frequently with rotary than with manual preparation. The correct preparation length was achieved significantly (P < 0.05) more often with rotary Ni-Ti files than with manual stainless steel files. Fractures occurred significantly (P < 0.05) less frequently with hand instrumentation. The mean time required for manual preparation was significantly (P < 0.001) longer than that required for rotary preparation. Prior experience with a hand preparation technique was not reflected in an improved quality of the subsequent engine-driven preparation. Inexperienced operators achieved better canal preparations with rotary Ni-Ti instruments than with manual stainless steel files. However, rotary preparation was associated with significantly more fractures.

  15. Ankle Spatting Compared to Bracing or Taping during Maximal-Effort Sprint Drills

    PubMed Central

    REUTER, GRANT D; DAHL, ANGELA R; SENCHINA, DAVID S

    2011-01-01

    The purpose of this study was to compare the influences of 4 ankle conditions (no support, bracing, taping, taping + spatting; all in football cleats) during 2 maximal-effort field drills (40-yd dash and 34-yd cutting drill) on perceptions of comfort and stability and performance outcomes. Fourteen young adult males participated. Subjects’ perceptions of comfort and stability were assessed by visual analogue scales after each drill for each ankle condition. Time-to-completion and post-completion heart rate were recorded. For both drills, significant differences in comfort perception were found such that subjects perceived no support as equivocal to bracing but more comfortable than either taping or spatting + taping. Stability results differed by drill. For the dash, significant differences in stability perception were found such that subjects perceived no support as equivocal to bracing but less stable than either taping or spatting + taping. By contrast, for the cutting drill significant differences in stability perception were found such that subjects perceived their ankles as less stable during the no support condition as compared to all 3 other conditions. Generally, bracing was perceived as equivocal to all 3 other conditions for comfort and stability. There were no significant differences in time-to-completion or heart rate for any comparison. Compared to bracing or taping, spatting + taping (a) did not influence performance time in explosive/sprint-type drills, (b) was perceived as equivalent to taping alone in terms of ankle comfort and stability, and (c) was perceived as equivalent to bracing in terms of stability but not comfort. PMID:27478530

  16. Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grin, A.; Lstiburek, J.

    The goal of this research is to provide durable and long-term water management solutions using exterior insulating sheathing as part of the water management system. It is possible to tape or seal the joints in insulating sheathing to create a drainage plane and even an air control layer. There exists the material durability component of the tape as well as the system durability component being the taped insulating sheathing as the drainage plane. This measure guideline provides best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant issues weremore » discussed with the group, which are required to make taped insulating sheathing a simple, long-term, and durable drainage plane: horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists use superior materials; and frequent installation inspection and regular trade training are required to maintain proper installation.« less

  17. Kinesio Taping effects on knee extension force among soccer players

    PubMed Central

    Serra, Maysa V. G. B.; Vieira, Edgar R.; Brunt, Denis; Goethel, Márcio F.; Gonçalves, Mauro; Quemelo, Paulo R. V.

    2015-01-01

    Background: Kinesio Taping (KT) is widely used, however the effects of KT on muscle activation and force are contradictory. Objective: To evaluate the effects of KT on knee extension force in soccer players. Method: This is a clinical trial study design. Thirty-four subjects performed two maximal isometric voluntary contractions of the lower limbs pre, immediately post, and 24 hours after tape application on the lower limbs. Both lower limbs were taped, using K-Tape and 3M Micropore tape randomly on the right and left thighs of the participants. Isometric knee extension force was measured for dominant side using a strain gauge. The following variables were assessed: peak force, time to peak force, rate of force development until peak force, time to peak rate of force development, and 200 ms pulse. Results: There were no statistically significant differences in the variables assessed between KT and Micropore conditions (F=0.645, p=0.666) or among testing sessions (pre, post, and 24h after) (F=0.528, p=0.868), and there was no statistical significance (F=0.271, p=0.986) for interaction between tape conditions and testing session. Conclusion: KT did not affect the force-related measures assessed immediately and 24 hours after the KT application compared with Micropore application, during maximal isometric voluntary knee extension. PMID:25789557

  18. Corrosion of metal particle and metal evaporated tapes

    NASA Technical Reports Server (NTRS)

    Speliotis, Dennis E.

    1991-01-01

    Very high coercivity metal particle (MP) and metal evaporated (ME) tapes are being used in 8mm video and digital audio tape applications, and more recently in digital data recording applications. In view of the inherent susceptibility of such media to environmental corrosion, a number of recent studies have addressed their long term stability and archivability. These studies have used an accelerated corrosion test based either on elevated temperature-humidity or polluting gas atmospheres known as Battelle tests. A comparison of the Battelle test results performed at different laboratories reveals a large variation from one location to another, presumably due to incorrect replication of the Battelle condition. Furthermore, when the Battelle tests are performed on enclosed cartridges, it is quite possible that diffusion limits the penetration of the extremely low concentration polluting gaseous species to the inner layers of the tapes during the short time of the accelerated test, whereas in real life these diffusion limitations may not apply. To avoid this uncertainty, the corrosion behavior of commercial 8mm MP and ME tapes when cassettes without their external plastic cases were exposed to 50 deg C and 80 percent RH for 7.5 weeks is investigated.

  19. Flexible storage medium for write-once optical tape

    NASA Technical Reports Server (NTRS)

    Strandjord, Andrew J. G.; Webb, Steven P.; Perettie, Donald J.; Cipriano, Robert A.

    1993-01-01

    A write-once data storage media was developed which is suitable for optical tape applications. The media is manufactured using a continuous film process to deposit a ternary alloy of tin, bismuth, and copper. This laser sensitive layer is sputter deposited onto commercial plastic web as a single-layer thin film. A second layer is sequentially deposited on top of the alloy to enhance the media performance and act as an abrasion resistant hard overcoat. The media was observed to have laser write sensitivities of less than 2.0 njoules/bit, carrier-to-noise levels of greater than 50dB's, modulation depths of approximately 100 percent, read-margins of greater than 35, uniform grain sizes of less than 200 Angstroms, and a media lifetime that exceeds 10 years. Prototype tape media was produced for use in the CREO drive system. The active and overcoat materials are first sputter deposited onto three mil PET film in a single pass through the vacuum coating system, and then converted down into multiple reels of 35mm x 880m tape. One mil PET film was also coated in this manner and then slit and packaged into 3480 tape cartridges.

  20. Simulation of Stress-Strain State of Shovel Rotary Support Kingpin

    NASA Astrophysics Data System (ADS)

    Khoreshok, A. A.; Buyankin, P. V.; Vorobiev, A. V.; Dronov, A. A.

    2016-04-01

    The article presents the sequence of computational simulation of stress-strain state of shovel’s rotary support. Computation results are analyzed, the kingpin is specified as the most loaded element, maximum stress zones are identified. Kingpin design modification such as enhancement of fillet curvature radius to 25 mm and displacement of eyebolt holes on the diameter of 165 mm are proposed, thus diminishing impact of stress concentrators and improving reliability of the rotary support.

  1. Effects of Corrective Taping on Balance and Gait in Patients With Hallux Valgus.

    PubMed

    Gur, Gozde; Ozkal, Ozden; Dilek, Burcu; Aksoy, Songul; Bek, Nilgun; Yakut, Yavuz

    2017-05-01

    Taping is an effective temporary therapy for improving hallux valgus (HV) in adults. Although HV has been demonstrated to impair postural balance, there is a lack of information about how corrective taping affects balance and gait patterns in adults with HV deformity. Eighteen middle-aged female patients (average age, 53.5 years) with HV were included. Corrective tape was applied to correct HV angulation. A series of balance and gait stability tests were performed before applying tape and 1 hour after the tape was applied with a Balance Master computerized posturography device. The study involved the following tests: modified clinical test of sensory interaction and balance (mCTSIB), unilateral stance (US), limit of stability (LoS), step up/over (SUO), and walk across (WA) tests. No significant difference was found between the no-tape and taped condition in the static balance mCTSIB and US tests ( P > .05). The taping intervention resulted in significant improvement in the dynamic balance measures for the LoS test's backward reaction time and left maximum excursion ( P < .05), a significantly higher impact index bilaterally in the SUO assessment ( P < .05), and an increase in step width mean and variability in the WA test ( P < .05). Taping for correcting HV angulation had negative acute effects on dynamic balance in the SUO and WA tests and positive effects in the LoS test. Corrective taping, although a form of conservative treatment for hallux valgus, has been insufficiently studied in terms of effects on balance. Our results show that taping, as an acute effect, may impair balance in middle-aged adults when walking or ascending and descending stairs.

  2. Effects of angular acceleration on man - Choice reaction time using visual and rotary motion information

    NASA Technical Reports Server (NTRS)

    Clark, B.; Stewart, J. D.

    1974-01-01

    This experiment was concerned with the effects of rotary acceleration on choice reaction time (RTc) to the motion of a luminous line on a cathode-ray tube. Specifically, it compared the (RTc) to rotary acceleration alone, visual acceleration alone, and simultaneous, double stimulation by both rotary and visual acceleration. Thirteen airline pilots were rotated about an earth-vertical axis in a precision rotation device while they observed a vertical line. The stimuli were 7 rotary and visual accelerations which were matched for rise time. The pilot responded as quickly as possible by displacing a vertical controller to the right or left. The results showed a decreasing (RTc) with increasing acceleration for all conditions, while the (RTc) to rotary motion alone was substantially longer than for all other conditions. The (RTc) to the double stimulation was significantly longer than that for visual acceleration alone.

  3. Rotary stripper for shielded and unshielded FCC

    NASA Technical Reports Server (NTRS)

    Angele, W.; Chambers, C. M.

    1971-01-01

    Rotary stripper removes narrow strips of insulation and shielding to any desired depth. Unshielded cables are stripped on both sides with one stroke, shielded cables are stripped in steps of different depths.

  4. Method for braze-joining spirally wound tapes to inner walls of heat exchanger tubes

    DOEpatents

    Garrison, Melton E.

    1984-01-01

    The present invention is directed to a method of fabricating heat exchanger tubes in which twisted tapes are utilized for promoting turbulence and heat transfer. The method of the present invention provides for the brazing of the tapes to the inner walls of the tubes for enhancing heat transfer between the fluid within the conduit and a fluid medium outside of the conduit by conduction through the tape. The braze joint of the present invention is coextensive with the tape over the entire length thereof within the conduit. The practice of the present invention is achieved by placing a filler wire of brazing metal along the tape at a location removed from the side walls and then heating the conduit and tape sufficiently to effect the displacement of the filler metal by wicking to the contact point between the tape and the conduit wall to form a braze joint coextensive with the length of the tape within the conduit. This arrangement provides maximum heat transfer and assures that the tape is in contact with the conduit over the entire common length thereof.

  5. Method for braze-joining spirally wound tapes to inner walls of heat exchanger tubes

    DOEpatents

    Garrison, M.E.

    1982-09-03

    The present invention is directed to a method of fabricating heat exchanger tubes in which twisted tapes are utilized for promoting turbulence and heat transfer. The method of the present invention provides for the brazing of the tapes to the inner walls of the tubes for enhancing heat transfer between the fluid within the conduit and a fluid medium outside of the conduit by conduction through the tape. The braze joint of the present invention is coextensive with the tape over the entire length thereof within the conduit. The practice of the present invention is achieved by placing a filler wire of brazing metal along the tape at a location removed from the side walls and then heating the conduit and tape sufficiently to effect the displacement of the filler metal by wicking to the contact point between the tape and the conduit wall to form a braze joint coextensive with the length of the tape within the conduit. This arrangement provides maximum heat transfer and assures that the tape is in contact with the conduit over the entire common length thereof.

  6. Osteotomy in direct sinus lift. A comparative study of the rotary technique and ultrasound

    PubMed Central

    Peñarrocha-Diago, Miguel; Sanchez-Recio, Cristina; Peñarrocha-Oltra, David; Romero-Millán, Javier

    2012-01-01

    Purpose: The present study investigates sinus membrane rupture in direct maxillary sinus lift with the rotary technique and with ultrasound, examining the survival of implants placed after sinus augmentation, and analyzing the bone gain obtained after the operation and 12 months after placement of the prosthetic restoration. Material and Methods: A retrospective study was made of 45 patients requiring maxillary sinus lift or augmentation for implant-prosthetic rehabilitation. Use was made of the hand piece and ostectomy drills for the rotary technique, and of specific tips for ultrasound. The implant success criteria were based on those developed by Buser. The bone gain obtained as a result of sinus lift was calculated from the postoperative panoramic X-rays. Results: A total of 57 direct elevations of the maxillary sinus were carried out: 32 with the rotary technique and 25 with ultrasound. Perforations of Schneider’s membrane with the rotary technique and ultrasound occurred in 7% and 1.7% of the cases, respectively, with membrane integrity being preserved in 91.2%. Of the 100 implants placed, 5 failed after one year of follow-up in the rotary technique group, while one implant failed in the ultrasound group. The rotary technique in turn afforded a bone gain of 5.9 mm, versus 6.7 mm with ultrasound. Conclusions: Perforations of the membrane sinusal in direct lift were more frequent with the rotary technique (7%) than with ultrasound (1.7%). Implant survival and bone gain were both greater when ultrasound was used. Key words:Bone sectioning, maxillary sinus augmentation, piezosurgery. PMID:22143735

  7. Textured substrate tape and devices thereof

    DOEpatents

    Goyal, Amit

    2006-08-08

    A method for forming a sharply biaxially textured substrate, such as a single crystal substrate, includes the steps of providing a deformed metal substrate, followed by heating above the secondary recrystallization temperature of the deformed substrate, and controlling the secondary recrystallization texture by either using thermal gradients and/or seeding. The seed is selected to shave a stable texture below a predetermined temperature. The sharply biaxially textured substrate can be formed as a tape having a length of 1 km, or more. Epitaxial articles can be formed from the tapes to include an epitaxial electromagnetically active layer. The electromagnetically active layer can be a superconducting layer.

  8. Recording and wear characteristics of 4 and 8 mm helical scan tapes

    NASA Technical Reports Server (NTRS)

    Peter, Klaus J.; Speliotis, Dennis E.

    1993-01-01

    Performance data of media on helical scan tape systems (4 and 8 mm) is presented and various types of media are compared. All measurements were performed on a standard MediaLogic model ML4500 Tape Evaluator System with a Flash Converter option for time based measurements. The 8 mm tapes are tested on an Exabyte 8200 drive and 4 mm tapes on an Archive Python drive; in both cases, the head transformer is directly connected to a Media Logic Read/Write circuit and test electronics. The drive functions only as a tape transport and its data recover circuits are not used. Signal to Noise, PW 50, Peak Shift and Wear Test data is used to compare the performance of MP (metal particle), BaFe, and metal evaporate (ME). ME tape is the clear winner in magnetic performance but its susceptibility to wear and corrosion, make it less than ideal for data storage.

  9. Reconfigureable network node

    DOEpatents

    Vanderveen, Keith B [Tracy, CA; Talbot, Edward B [Livermore, CA; Mayer, Laurence E [Davis, CA

    2008-04-08

    Nodes in a network having a plurality of nodes establish communication links with other nodes using available transmission media, as the ability to establish such links becomes available and desirable. The nodes predict when existing communications links will fail, become overloaded or otherwise degrade network effectiveness and act to establish substitute or additional links before the node's ability to communicate with the other nodes on the network is adversely affected. A node stores network topology information and programmed link establishment rules and criteria. The node evaluates characteristics that predict existing links with other nodes becoming unavailable or degraded. The node then determines whether it can form a communication link with a substitute node, in order to maintain connectivity with the network. When changing its communication links, a node broadcasts that information to the network. Other nodes update their stored topology information and consider the updated topology when establishing new communications links for themselves.

  10. String and Sticky Tape Experiments.

    ERIC Educational Resources Information Center

    Edge, R. D., Ed.

    1979-01-01

    Explains how to demonstrate the fundamentals of one dimensional kinematics such as Newton's third law of motion, and collision between bodies, using simple materials of marbles, strings, sticky tape, drinking straws, and rubber bands. (GA)

  11. Scanning electron microscopy comparison of the cleaning efficacy of a root canal system by Nd:YAG laser and rotary instruments.

    PubMed

    Samiei, Mohammad; Pakdel, Seyyed Mahdi Vahid; Rikhtegaran, Sahand; Shakoei, Sahar; Ebrahimpour, Delaram; Taghavi, Pedram

    2014-08-01

    This study evaluated the cleaning efficacy of a root canal system by Nd:YAG laser and rotary instruments. Sixty single-rooted human teeth were divided into four experimental groups (n=15). In the first group the teeth were prepared with a step-back technique using conventional K-files. In the second and third groups, tooth preparation was carried out using Nd:YAG laser and rotary NiTi instruments, respectively. Teeth in the fourth group were prepared by combined laser and rotary methods. The smear layer remaining on canal walls was then assessed by scanning electron microscopy in the coronal, middle, and apical portions. The comparison of smear layer removal efficacy between groups was carried out by Kruskal-Wallis and Mann-Whitney U tests. The mean grades of smear layer removal in rotary-laser, rotary, laser and step-back techniques were 1.34 ± 0.18, 2.2 ± 0.28, 1.91 ± 0.25, and 2.42 ± 0.19, respectively. On the whole, differences between rotary-laser and rotary groups, step-back, and the three other techniques (rotary, laser, and rotary-laser) were significant at p=0.034. Based on the findings of this study, the cleaning efficacy of rotary, laser, and rotary-laser techniques were better than the step-back technique and the combined laser and rotary technique was the most efficient method.

  12. Helical tape forming device

    NASA Technical Reports Server (NTRS)

    Bush, J. E.; Cole, P. T.

    1969-01-01

    Using a device that is not limited to a minimum thickness or width-to-thickness ratio, a very thin metal tape or ribbon is formed into a continuous flat wound helical coil. The device imparts the desired circular shape by squeeze rolling it with an unequal force across its width.

  13. Kinematic control model for light weighting mechanism of excavator attached to rotary working device

    NASA Astrophysics Data System (ADS)

    Lee, Choongho; Lee, Sangsik; Cho, Youngtae; Im, Kwanghee

    2007-07-01

    An excavator attached to a rotary working device is used principally in industrial work. In particular, they are used in the building industry and public works. This research concerns the rotary automatic control of an excavator attached to a rotary working device. The drilling excavator is used in the crushed stone industry and the dragline excavation system is employed in the construction industry. Cases of the excavator's use in agriculture have been the subject of a relatively few studies. However, several modified excavator designs have been released in recent years. Applied excavator products are primarily utilized under relatively severe environmental conditions. In this study, we focus on the uses of an excavator in agricultural work. The readjustment of arable land and the reduction of weeds in agricultural applications both require skilled hand-operation of the machines. As such workers have been shown to develop problems with regard to working posture and proper positioning while laboring, a more appropriate excavator design may prove useful in such applications. Therefore, this pilot study is focused primarily on the rotary automatic control of an excavator attached to a rotary working device, and will adapt smart materials to the excavator applications for developing redesigned excavator having a light weight. The excavator is attached to a rotary working device on a normal excavator's platform, and the position and orientation of the mechanism between the joints and the rotary working device was determined. Simulations were also conducted of the excavator attached to the rotary working device. With an eye toward the use of this mechanism in agricultural work, we also conducted a set of kinematic analyses. The rotary working device was assumed to have 3 DOF, and was comprised of 5 links. Computer simulations were also conducted using the developed excavator model. In order to adequately evaluate the possible performance of such a system, kinetic

  14. Does Kinesiology tape counter exercise-related impairments of balance in the elderly?

    PubMed

    Hosp, Simona; Csapo, Robert; Heinrich, Dieter; Hasler, Michael; Nachbauer, Werner

    2018-05-01

    Maintaining balance is an essential requirement for the performance of daily tasks and sporting activities, particularly in older adults to prevent falls and associated injuries. Kinesiology tape has gained great popularity in sports and is frequently used as a tool for performance enhancement. However, there is little research investigating its influence on balance. The purpose of this study was to evaluate the effect of Kinesiology tape on dynamic balance, postural stability and knee proprioception after physical activity in healthy, older adults. Twelve physically active, healthy men aged 63-77 years performed the test on two separate days, with and without Kinesiology tape at the knee joint (prospective intervention with cross-over design). Dynamic balance during an obstacle-crossing task, postural stability in a single-leg stance test, and knee joint position sense as a measure of proprioception were examined before and after 30 min of downhill walking on a treadmill. The influences of taping condition and physical activity on all parameters were statistically tested using factorial ANOVAs. Factorial ANOVA revealed significant time × taping condition interaction effects on all performance parameters (p < 0.05), indicating that the exercise-related changes in dynamic balance, postural stability and knee proprioception differed between the two taping conditions. The deterioration of performance was always greater when no tape was used. This study demonstrated that physical exercise significantly deteriorated dynamic balance, postural stability and knee proprioception in older men. These effects can be attenuated through the usage of Kinesiology tape. By preventing exercise-related impairments of balance, Kinesiology tape might help reduce the risk of sports-associated falls and associated injuries. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Thermal Edge-Effects Model for Automated Tape Placement of Thermoplastic Composites

    NASA Technical Reports Server (NTRS)

    Costen, Robert C.

    2000-01-01

    Two-dimensional thermal models for automated tape placement (ATP) of thermoplastic composites neglect the diffusive heat transport that occurs between the newly placed tape and the cool substrate beside it. Such lateral transport can cool the tape edges prematurely and weaken the bond. The three-dimensional, steady state, thermal transport equation is solved by the Green's function method for a tape of finite width being placed on an infinitely wide substrate. The isotherm for the glass transition temperature on the weld interface is used to determine the distance inward from the tape edge that is prematurely cooled, called the cooling incursion Delta a. For the Langley ATP robot, Delta a = 0.4 mm for a unidirectional lay-up of PEEK/carbon fiber composite, and Delta a = 1.2 mm for an isotropic lay-up. A formula for Delta a is developed and applied to a wide range of operating conditions. A surprise finding is that Delta a need not decrease as the Peclet number Pe becomes very large, where Pe is the dimensionless ratio of inertial to diffusive heat transport. Conformable rollers that increase the consolidation length would also increase Delta a, unless other changes are made, such as proportionally increasing the material speed. To compensate for premature edge cooling, the thermal input could be extended past the tape edges by the amount Delta a. This method should help achieve uniform weld strength and crystallinity across the width of the tape.

  16. phylo-node: A molecular phylogenetic toolkit using Node.js.

    PubMed

    O'Halloran, Damien M

    2017-01-01

    Node.js is an open-source and cross-platform environment that provides a JavaScript codebase for back-end server-side applications. JavaScript has been used to develop very fast and user-friendly front-end tools for bioinformatic and phylogenetic analyses. However, no such toolkits are available using Node.js to conduct comprehensive molecular phylogenetic analysis. To address this problem, I have developed, phylo-node, which was developed using Node.js and provides a stable and scalable toolkit that allows the user to perform diverse molecular and phylogenetic tasks. phylo-node can execute the analysis and process the resulting outputs from a suite of software options that provides tools for read processing and genome alignment, sequence retrieval, multiple sequence alignment, primer design, evolutionary modeling, and phylogeny reconstruction. Furthermore, phylo-node enables the user to deploy server dependent applications, and also provides simple integration and interoperation with other Node modules and languages using Node inheritance patterns, and a customized piping module to support the production of diverse pipelines. phylo-node is open-source and freely available to all users without sign-up or login requirements. All source code and user guidelines are openly available at the GitHub repository: https://github.com/dohalloran/phylo-node.

  17. Application of Kinesio Taping method for newborn swallowing difficultly

    PubMed Central

    Lin, Chien-Lin; Wu, Wei-Ting; Chang, Ke-Vin; Lin, Hong-Yi; Chou, Li-Wei

    2016-01-01

    Abstract Background: Preterm infants are at an increased risk of sucking problems, swallowing difficulty, and poor nourishment. During the neonatal period, the neurobehavioral organization of a preterm baby is poor compared with that of appropriate gestational age infants. Kinesio Taping has been widely used for edema control, joint protection, and proprioception training. With the help of augmentation of the sensory input for muscle facilitation and inhibition through tapping, the coordination of the target muscle groups can be improved. Until now, no research is available on the use of Kinesio Taping for the swallowing difficulty of infant. Methods: We reported a preterm infant suffering from brain edema at birth and swallowing difficultly until 40 weeks. The swallowing reflex was delayed. Moreover, lip closure and rooting reflex combined with the dysfunction grade of jaw movement were poor. We performed KT methods on the baby under the theory of the direction of the tape for facilitate or inhibit the muscle. Result: After the Kinesio Taping treatment, the sucking function was improved with good lip closure.One week later, the baby was discharged without the use of an oral gastric tube. Conclusion: Kinesio Taping contributed significantly to the improvement of impaired sucking and swallowing and could be implemented as a regular rehabilitative approach for infants suffering from these difficulties. PMID:27495080

  18. Implicit Geometry Meshing for the simulation of Rotary Friction Welding

    NASA Astrophysics Data System (ADS)

    Schmicker, D.; Persson, P.-O.; Strackeljan, J.

    2014-08-01

    The simulation of Rotary Friction Welding (RFW) is a challenging task, since it states a coupled problem of phenomena like large plastic deformations, heat flux, contact and friction. In particular the mesh generation and its restoration when using a Lagrangian description of motion is of significant severity. In this regard Implicit Geometry Meshing (IGM) algorithms are promising alternatives to the more conventional explicit methods. Because of the implicit description of the geometry during remeshing, the IGM procedure turns out to be highly robust and generates spatial discretizations of high quality regardless of the complexity of the flash shape and its inclusions. A model for efficient RFW simulation is presented, which is based on a Carreau fluid law, an Augmented Lagrange approach in mapping the incompressible deformations, a penalty contact approach, a fully regularized Coulomb-/fluid friction law and a hybrid time integration strategy. The implementation of the IGM algorithm using 6-node triangular finite elements is described in detail. The techniques are demonstrated on a fairly complex friction welding problem, demonstrating the performance and the potentials of the proposed method. The techniques are general and straight-forward to implement, and offer the potential of successful adoption to a wide range of other engineering problems.

  19. The Broselow and Handtevy Resuscitation Tapes: A Comparison of the Performance of Pediatric Weight Prediction.

    PubMed

    Lowe, Calvin G; Campwala, Rashida T; Ziv, Nurit; Wang, Vincent J

    2016-08-01

    To assess the performance of two pediatric length-based tapes (Broselow and Handtevy) in predicting actual weights of US children. In this descriptive study, weights and lengths of children (newborn through 13 years of age) were extracted from the 2009-2010 National Health and Nutrition Examination Survey (NHANES). Using the measured length ranges for each tape and the NHANES-extracted length data, every case from the study sample was coded into Broselow and Handtevy zones. Mean weights were calculated for each zone and compared to the predicted Broselow and Handtevy weights using measures of bias, precision, and accuracy. A sub-sample was examined that excluded cases with body mass index (BMI)≥95th percentile. Weights of children longer than each tape also were examined. A total of 3,018 cases from the NHANES database met criteria. Although both tapes underestimated children's weight, the Broselow tape outperformed the Handtevy tape across most length ranges in measures of bias, precision, and accuracy of predicted weights relative to actual weights. Accuracy was higher in the Broselow tape for shorter children and in the Handtevy tape for taller children. Among the sub-sample with cases of BMI≥95th percentile removed, performance of the Handtevy tape improved, yet the Broselow tape still performed better. When assessing the weights of children who were longer than either tape, the actual mean weights did not approximate adult weights; although, those exceeding the Handtevy tape were closer. For pediatric weight estimation, the Broselow tape performed better overall than the Handtevy tape and more closely approximated actual weight. Lowe CG , Campwala RT , Ziv N , Wang VJ . The Broselow and Handtevy resuscitation tapes: a comparison of the performance of pediatric weight prediction. Prehosp Disaster Med. 2016;31(4):364-375.

  20. Smart Bandwidth Assignation in an Underlay Cellular Network for Internet of Vehicles.

    PubMed

    de la Iglesia, Idoia; Hernandez-Jayo, Unai; Osaba, Eneko; Carballedo, Roberto

    2017-09-27

    The evolution of the IoT (Internet of Things) paradigm applied to new scenarios as VANETs (Vehicular Ad Hoc Networks) has gained momentum in recent years. Both academia and industry have triggered advanced studies in the IoV (Internet of Vehicles), which is understood as an ecosystem where different types of users (vehicles, elements of the infrastructure, pedestrians) are connected. How to efficiently share the available radio resources among the different types of eligible users is one of the important issues to be addressed. This paper briefly analyzes various concepts presented hitherto in the literature and it proposes an enhanced algorithm for ensuring a robust co-existence of the aforementioned system users. Therefore, this paper introduces an underlay RRM (Radio Resource Management) methodology which is capable of (1) improving cellular spectral efficiency while making a minimal impact on cellular communications and (2) ensuring the different QoS (Quality of Service) requirements of ITS (Intelligent Transportation Systems) applications. Simulation results, where we compare the proposed algorithm to the other two RRM, show the promising spectral efficiency performance of the proposed RRM methodology.

  1. Smart Bandwidth Assignation in an Underlay Cellular Network for Internet of Vehicles

    PubMed Central

    de la Iglesia, Idoia; Hernandez-Jayo, Unai

    2017-01-01

    The evolution of the IoT (Internet of Things) paradigm applied to new scenarios as VANETs (Vehicular Ad Hoc Networks) has gained momentum in recent years. Both academia and industry have triggered advanced studies in the IoV (Internet of Vehicles), which is understood as an ecosystem where different types of users (vehicles, elements of the infrastructure, pedestrians) are connected. How to efficiently share the available radio resources among the different types of eligible users is one of the important issues to be addressed. This paper briefly analyzes various concepts presented hitherto in the literature and it proposes an enhanced algorithm for ensuring a robust co-existence of the aforementioned system users. Therefore, this paper introduces an underlay RRM (Radio Resource Management) methodology which is capable of (1) improving cellular spectral efficiency while making a minimal impact on cellular communications and (2) ensuring the different QoS (Quality of Service) requirements of ITS (Intelligent Transportation Systems) applications. Simulation results, where we compare the proposed algorithm to the other two RRM, show the promising spectral efficiency performance of the proposed RRM methodology. PMID:28953256

  2. Performance of preformed plastic tapes.

    DOT National Transportation Integrated Search

    1982-01-01

    This study was initiated to investigate the overall performance of preformed pavement marking tapes with respect to their appearance, durability, and night visibility, and to recommend criteria for the selection of such materials based on their perfo...

  3. 33 CFR 100.914 - Trenton Rotary Roar on the River, Trenton, MI.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Trenton Rotary Roar on the River, Trenton, MI. 100.914 Section 100.914 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.914 Trenton Rotary Roar on...

  4. Study of advanced rotary combustion engines for commuter aircraft

    NASA Technical Reports Server (NTRS)

    Berkowitz, M.; Jones, C.; Myers, D.

    1983-01-01

    Performance, weight, size, and maintenance data for advanced rotary aircraft engines suitable for comparative commuter aircraft system evaluation studies of alternate engine candidates are provided. These are turbocharged, turbocompounded, direct injected, stratified charge rotary engines. Hypothetical engines were defined (an RC4-74 at 895 kW and an RC6-87 at 1490 kW) based on the technologies and design approaches used in the highly advanced engine of a study of advanced general aviation rotary engines. The data covers the size range of shaft power from 597 kW (800 hp) to 1865 kW (2500 hp) and is in the form of drawings, tables, curves and written text. These include data on internal geometry and configuration, installation information, turbocharging and turbocompounding arrangements, design features and technologies, engine cooling, fuels, scaling for weight size BSFC and heat rejection for varying horsepower, engine operating and performance data, and TBO and maintenance requirements. The basic combustion system was developed and demonstrated; however the projected power densities and performance efficiencies require increases in engine internal pressures, thermal loading, and rotative speed.

  5. Fragmentation of Newtonian and viscoelastic liquids during rotary atomization

    NASA Astrophysics Data System (ADS)

    Keshavarz, Bavand; Moore, John; Houze, Eric; Koerner, Michael; McKinley, Gareth; MIT Collaboration; Axalta Coating Systems Collaboration

    2015-11-01

    Animals drying their wet fur by rapidly shaking their body and rotary atomization in paint coating are just a few examples in which centripetal acceleration is used to disintegrate liquid films into smaller fragments. Narrower size distributions and well-defined geometrical fluid pathlines (similar to the involute of a circle) are the main advantages of this type of atomization as compared to air-assisted atomization. Despite these inherent advantages there is a paucity of fundamental knowledge about the roles of fluid rheology in this process. We study the effects of viscosity by performing rotary atomization tests on silicone oils with a wide range of viscosities (1-1000 mPa.s). Viscoelastic effects are also probed by spraying solutions of polyethylene oxide (PEO) dissolved in water at different concentrations. Our results show that understanding the effects of liquid properties on the instabilities that control rotary atomization (primarily Rayleigh-Taylor instability during the ligament formation followed by Rayleigh-Plateau instability during droplet pinch-off) can help us understand the resulting fragment size distributions.

  6. One-step Tape Casting of Composites via Slurry on Fiber

    NASA Technical Reports Server (NTRS)

    deGroh, Henry C., III

    2001-01-01

    A process by which metal matrix composites can be made was presented. The process involves putting a powder slurry on fibers to make a precursor green tape. These green tapes are cut, stacked and hot pressed to form the fully dense composite. A computer program was presented which enables complete quantification and control of the process. Once some easily obtained properties of the slurry and its behavior are determined (such as the shrinkage from the wet to green state, and the density of the green tape) modification of the fiber spacing and blade height give the maker precise control of fiber volume fraction, and fiber architecture in the composite. The process was shown to be accurate and flexible through the production of a wide variety of volume fraction fiber composites made from a wide variety of fibers and powders. The most time consuming step of the tape casting process (other than hot pressing) was winding the fiber on the drum. The tape casting techniques developed resulted in high quality metal matrix composites, with ultimate tensile strength in the range of 215 ksi (1477 MPa), a strain at failure of 1.15 percent, and in fatigue at room temperature 0 to 120 ksi, n = 0.3 Hz, a 4-ply Ti-24Al-11Nb/SCS-6, 32 vol% fiber tape cast composite lasted 202,205 cycles with a maximum strain on the 100th cycle of 0.43 percent.

  7. A Survey on Nickel Titanium Rotary Instruments and their Usage Techniques by Endodontists in India

    PubMed Central

    Saraf, Prahlad A; Penukonda, Raghavendra; Vanaki, Sneha S; Kamatagi, Laxmikant

    2017-01-01

    Introduction The preference and usage of nickel titanium rotary instruments varies from individual to individual based on their technique, experience with the rotary systems and the clinical situation. Very limited information is available to explain the adoption of changing concepts with respect to nickel titanium rotary instruments pertaining to the endodontists in India. Aim The aim of this study was to conduct a questionnaire survey to acquire the knowledge concerning different NiTi rotary instruments and their usage techniques by endodontists in India. Materials and Methods A Survey questionnaire was designed which consisted of 32 questions regarding designation, demographics, experience with rotary instruments, usage of different file systems, usage techniques, frequency of reuse, occurrence of file fracture, reasons and their management was distributed by hand in the national postgraduate convention and also disseminated via electronic medium to 400 and 600 endodontists respectively. Information was collected from each individual to gain insight into the experiences and beliefs of endodontists concerning the new endodontic technology of rotary NiTi instrumentation based on their clinical experience with the rotary systems. The questions were designed to ascertain the problems, patterns of use and to identify areas of perceived or potential concern regarding the rotary instruments and the data acquired was statistically evaluated using Fisher’s-exact test and the Chi-Square test. Results Overall 63.8% (638) endodontists responded. ProTaper was one of the most commonly used file system followed by M two and ProTaper Next. There was a significant co relation between the years of experience and the file re use frequency, preparation technique, file separation, management of file separation. Conclusion A large number of Endodontists prefer to reuse the rotary NiTi instruments. As there was an increase in the experience, the incidence of file separation reduced

  8. An economic analysis for optimal distributed computing resources for mask synthesis and tape-out in production environment

    NASA Astrophysics Data System (ADS)

    Cork, Chris; Lugg, Robert; Chacko, Manoj; Levi, Shimon

    2005-06-01

    With the exponential increase in output database size due to the aggressive optical proximity correction (OPC) and resolution enhancement technique (RET) required for deep sub-wavelength process nodes, the CPU time required for mask tape-out continues to increase significantly. For integrated device manufacturers (IDMs), this can impact the time-to-market for their products where even a few days delay could have a huge commercial impact and loss of market window opportunity. For foundries, a shorter turnaround time provides a competitive advantage in their demanding market, too slow could mean customers looking elsewhere for these services; while a fast turnaround may even command a higher price. With FAB turnaround of a mature, plain-vanilla CMOS process of around 20-30 days, a delay of several days in mask tapeout would contribute a significant fraction to the total time to deliver prototypes. Unlike silicon processing, masks tape-out time can be decreased by simply purchasing extra computing resources and software licenses. Mask tape-out groups are taking advantage of the ever-decreasing hardware cost and increasing power of commodity processors. The significant distributability inherent in some commercial Mask Synthesis software can be leveraged to address this critical business issue. Different implementations have different fractions of the code that cannot be parallelized and this affects the efficiency with which it scales, as is described by Amdahl"s law. Very few are efficient enough to allow the effective use of 1000"s of processors, enabling run times to drop from days to only minutes. What follows is a cost aware methodology to quantify the scalability of this class of software, and thus act as a guide to estimating the optimal investment in terms of hardware and software licenses.

  9. Zink rotary kiln seal: Cam followers. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisher, D.L.

    1994-12-09

    The CIF will treat hazardous and mixed low-level radioactive waste in a rotary kiln and secondary combustion chamber. A high efficiency air pollution control system follows the secondary chamber. The rotary kiln is designed with a gas seal at each end of its rotating barrel which provides a barrier between the interior of the kiln and outside air. The internal pressure of the rotary kiln will be maintained below atmospheric pressure, so exterior air passing the seals is forced into the kiln`s interior. Positive pressure may be applied in the seal labyrinth, adding a barrier to flow. Both CIF sealsmore » will be covered entirely with exhaust hoods, drawing air over the outside of the seal and into a HEPA filtered exhaust system. Cam follower misalignment on a John Zink rotary kiln seal caused damage to the seal`s rotor. The misalignment was quantified, corrected, and checked to verify straightness. The primary purpose of the correction was to allow seal testing 1 to continue, but the information is applicable to the Consolidated Incineration Facility (CIF) since two large seals of similar design will be installed there. Cam follower straightness was off as much as 3.5{degrees}, causing followers to run untrue on the rotor. High contact forces resulted, removing flakes of metal from the rotor surface. The misalignment caused weight bearing followers on one side of the seal to back out of their threaded mounts. The root cause was poor machining of the follower mounting holes. Correction was accomplished by relieving the holes and installing machined spacers and retaining nuts. Cam followers on the CIF`s Zink seals should be inspected for straightness before the seals are installed.« less

  10. Lensless, ultra-wideband fiber optic rotary joint for biomedical applications.

    PubMed

    Kim, Wihan; Chen, Xi; Jo, Javier A; Applegate, Brian E

    2016-05-01

    The demands of optical fiber-based biomedical applications can, in many cases, outstrip the capabilities of lens-based commercially available fiber optic rotary joints. In some circumstances, it is necessary to use very broad spectral bandwidths (near UV to short-wave IR) and specialized optical fibers, such as double-clad fiber, and have the capacity to accommodate high rotational velocities. The broad spectrum, stretching down into the UV, presents two problems: (1) adequate chromatic correction in the lenses across the entire bandwidth and (2) strong UV absorption by the fluids used to lubricate the rotary joint. To accommodate these types of applications, we have developed an ultra-wideband lensless fiber optic rotary joint based on the principle that when two optical fibers are coaligned and placed in contact (or very close), the optical losses at the junction are very low. The advances demonstrated here enable excellent performance (<0.2  dB insertion loss), even down into the UV and spanning a wavelength range of at least 355-1360 nm with single-mode, multimode, and double-clad fibers. We also demonstrate excellent performance, ∼0.38  dB insertion loss, at rotational velocities up to 8800 rpm (146 Hz). To the best of our knowledge, this is the first demonstration of this type of rotary joint capable of such a wide bandwidth and high rotational velocities.

  11. Transaction aware tape-infrastructure monitoring

    NASA Astrophysics Data System (ADS)

    Nikolaidis, Fotios; Kruse, Daniele Francesco

    2014-06-01

    Administrating a large scale, multi protocol, hierarchical tape infrastructure like the CERN Advanced STORage manager (CASTOR)[2], which stores now 100 PB (with an increasing step of 25 PB per year), requires an adequate monitoring system for quick spotting of malfunctions, easier debugging and on demand report generation. The main challenges for such system are: to cope with CASTOR's log format diversity and its information scattered among several log files, the need for long term information archival, the strict reliability requirements and the group based GUI visualization. For this purpose, we have designed, developed and deployed a centralized system consisting of four independent layers: the Log Transfer layer for collecting log lines from all tape servers to a single aggregation server, the Data Mining layer for combining log data into transaction context, the Storage layer for archiving the resulting transactions and finally the Web UI layer for accessing the information. Having flexibility, extensibility and maintainability in mind, each layer is designed to work as a message broker for the next layer, providing a clean and generic interface while ensuring consistency, redundancy and ultimately fault tolerance. This system unifies information previously dispersed over several monitoring tools into a single user interface, using Splunk, which also allows us to provide information visualization based on access control lists (ACL). Since its deployment, it has been successfully used by CASTOR tape operators for quick overview of transactions, performance evaluation, malfunction detection and from managers for report generation.

  12. Digital terrain tapes: user guide

    USGS Publications Warehouse

    ,

    1980-01-01

    DMATC's digital terrain tapes are a by-product of the agency's efforts to streamline the production of raised-relief maps. In the early 1960's DMATC developed the Digital Graphics Recorder (DGR) system that introduced new digitizing techniques and processing methods into the field of three-dimensional mapping. The DGR system consisted of an automatic digitizing table and a computer system that recorded a grid of terrain elevations from traces of the contour lines on standard topographic maps. A sequence of computer accuracy checks was performed and then the elevations of grid points not intersected by contour lines were interpolated. The DGR system produced computer magnetic tapes which controlled the carving of plaster forms used to mold raised-relief maps. It was realized almost immediately that this relatively simple tool for carving plaster molds had enormous potential for storing, manipulating, and selectively displaying (either graphically or numerically) a vast number of terrain elevations. As the demand for the digital terrain tapes increased, DMATC began developing increasingly advanced digitizing systems and now operates the Digital Topographic Data Collection System (DTDCS). With DTDCS, two types of data elevations as contour lines and points, and stream and ridge lines are sorted, matched, and resorted to obtain a grid of elevation values for every 0.01 inch on each map (approximately 200 feet on the ground). Undefined points on the grid are found by either linear or or planar interpolation.

  13. Arch-Taping Techniques for Altering Navicular Height and Plantar Pressures During Activity

    PubMed Central

    Newell, Tim; Simon, Janet; Docherty, Carrie L.

    2015-01-01

    Context Arch tapings have been used to support the arch by increasing navicular height. Few researchers have studied navicular height and plantar pressures after physical activity. Objective To determine if taping techniques effectively support the arch during exercise. Design Crossover study. Setting Athletic training research laboratory. Patients or Other Participants Twenty-five individuals (13 men, 12 women; age = 20.0 ± 1.0 years, height = 172.3 ± 6.6 cm, mass = 70.1 ± 10.2 kg) with a navicular drop of more than 8 mm (12.9 ± 3.3 mm) volunteered. Intervention(s) All individuals participated in 3 days of testing, with 1 day for each tape condition: no tape, low dye, and navicular sling. On each testing day, navicular height and plantar pressures were measured at 5 intervals: baseline; posttape; and after 5, 10, and 15 minutes of running. The order of tape condition was counterbalanced. Main Outcome Measure(s) The dependent variables were navicular height in millimeters and plantar pressures in kilopascals. Plantar pressures were divided into 5 regions: medial forefoot, lateral forefoot, lateral midfoot, lateral rearfoot, and medial rearfoot. Separate repeated-measures analyses of variance were conducted for each dependent variable. Results Navicular height was higher immediately after application of the navicular-sling condition (P = .004) but was reduced after 5 minutes of treadmill running (P = .12). We observed no differences from baseline to posttape for navicular height for the low-dye (P = .30) and no-tape conditions (P = .25). Both the low-dye and navicular-sling conditions increased plantar pressures in the lateral midfoot region compared with the no-tape condition. The low-dye condition created decreased pressure in the medial and lateral forefoot regions compared with the no-tape condition. All changes were identified immediately after application and were maintained during running. No changes were noted in plantar pressures for the no-tape

  14. High-throughput DNA extraction of forensic adhesive tapes.

    PubMed

    Forsberg, Christina; Jansson, Linda; Ansell, Ricky; Hedman, Johannes

    2016-09-01

    Tape-lifting has since its introduction in the early 2000's become a well-established sampling method in forensic DNA analysis. Sampling is quick and straightforward while the following DNA extraction is more challenging due to the "stickiness", rigidity and size of the tape. We have developed, validated and implemented a simple and efficient direct lysis DNA extraction protocol for adhesive tapes that requires limited manual labour. The method uses Chelex beads and is applied with SceneSafe FAST tape. This direct lysis protocol provided higher mean DNA yields than PrepFiler Express BTA on Automate Express, although the differences were not significant when using clothes worn in a controlled fashion as reference material (p=0.13 and p=0.34 for T-shirts and button-down shirts, respectively). Through in-house validation we show that the method is fit-for-purpose for application in casework, as it provides high DNA yields and amplifiability, as well as good reproducibility and DNA extract stability. After implementation in casework, the proportion of extracts with DNA concentrations above 0.01ng/μL increased from 71% to 76%. Apart from providing higher DNA yields compared with the previous method, the introduction of the developed direct lysis protocol also reduced the amount of manual labour by half and doubled the potential throughput for tapes at the laboratory. Generally, simplified manual protocols can serve as a cost-effective alternative to sophisticated automation solutions when the aim is to enable high-throughput DNA extraction of complex crime scene samples. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  15. The machined surface of magnesium AZ31 after rotary turning at air cooling condition

    NASA Astrophysics Data System (ADS)

    Akhyar, G.; Purnomo, B.; Hamni, A.; Harun, S.; Burhanuddin, Y.

    2018-04-01

    Magnesium is a lightweight metal that is widely used as an alternative to iron and steel. Magnesium has been applied in the automotive industry to reduce the weight of a component, but the machining process has the disadvantage that magnesium is highly flammable because it has a low flash point. High temperature can cause the cutting tool wear and contributes to the quality of the surface roughness. The purpose of this study is to obtain the value of surface roughness and implement methods of rotary cutting tool and air cooling output vortex tube cooler to minimize the surface roughness values. Machining parameters that is turning using rotary cutting tool at speed the workpiece of (Vw) 50, 120, 160 m/min, cutting speed of rotary tool of (Vt) 25, 50, 75 m/min, feed rate of (f) 0.1, 0.15, 0.2 mm/rev, and depth of cut of 0.3 mm. Type of tool used is a carbide tool diameter of 16 mm and air cooling pressure of 6 bar. The results show the average value of the lowest surface roughness on the speed the workpiece of 80 m/min, cutting speed of rotary tool of 50 m/min, feed rate of 0.2 mm/rev, and depth of cut of 0.3 mm. While the average value of the highest surface roughness on the speed the workpiece of 160 m/min, cutting speed of rotary tool of 50 m/min, feed rate of 0.2 mm/rev, and depth of cut of 0.3 mm. The influence of machining parameters concluded the higher the speed of the workpiece the surface roughness value higher. Otherwise the higher cutting speed of rotary tool then the lower the surface roughness value. The observation on the surface of the rotary tool, it was found that no uniform tool wear which causes non-uniform surface roughness. The use of rotary cutting tool contributing to lower surface roughness values generated.

  16. Stratified charge rotary aircraft engine technology enablement program

    NASA Technical Reports Server (NTRS)

    Badgley, P. R.; Irion, C. E.; Myers, D. M.

    1985-01-01

    The multifuel stratified charge rotary engine is discussed. A single rotor, 0.7L/40 cu in displacement, research rig engine was tested. The research rig engine was designed for operation at high speeds and pressures, combustion chamber peak pressure providing margin for speed and load excursions above the design requirement for a high is advanced aircraft engine. It is indicated that the single rotor research rig engine is capable of meeting the established design requirements of 120 kW, 8,000 RPM, 1,379 KPA BMEP. The research rig engine, when fully developed, will be a valuable tool for investigating, advanced and highly advanced technology components, and provide an understanding of the stratified charge rotary engine combustion process.

  17. Tape-recorded Lectures With Slide Synchronization

    ERIC Educational Resources Information Center

    Goodhue, D.

    1969-01-01

    Describes "Taped Explanation Slide Synchronization" programs used for individual study or group showing in college zoology. Discusses preparation of programs, class organization, equipment, and costs. (EB)

  18. Growth of carbon nanotubes (CNTs) on metallic underlayers by diffusion plasma-enhanced chemical vapour deposition (DPECVD)

    NASA Astrophysics Data System (ADS)

    Kim, S. M.; Gangloff, L.

    2009-10-01

    Here, we demonstrate the low-temperature (480-612 °C) synthesis of carbon nanotubes (CNTs) on different metallic underlayers (i.e., NiV, Ir, Ag, Pt, W, and Ta) using diffusion (dc) plasma-enhanced (~20 W, -600 V) chemical vapour deposition (DPECVD). The catalyst used is bi-layered Fe/Al and the feedstock used is a mixture of C 2H 2 and NH 3 (1:4). The crucial component is the diffusion of radical ions and hydrogen generated such as H 2/H +/H 2+/NH 3+/CH 2+/C 2H 2+ (which are confirmed by in-situ mass spectroscopy) from the nozzle, where it is inserted for most effective plasma diffusion between a substrate and a gas distributor.

  19. Research on resistance characteristics of YBCO tape under short-time DC large current impact

    NASA Astrophysics Data System (ADS)

    Zhang, Zhifeng; Yang, Jiabin; Qiu, Qingquan; Zhang, Guomin; Lin, Liangzhen

    2017-06-01

    Research of the resistance characteristics of YBCO tape under short-time DC large current impact is the foundation of the developing DC superconducting fault current limiter (SFCL) for voltage source converter-based high voltage direct current system (VSC-HVDC), which is one of the valid approaches to solve the problems of renewable energy integration. SFCL can limit DC short-circuit and enhance the interrupting capabilities of DC circuit breakers. In this paper, under short-time DC large current impacts, the resistance features of naked tape of YBCO tape are studied to find the resistance - temperature change rule and the maximum impact current. The influence of insulation for the resistance - temperature characteristics of YBCO tape is studied by comparison tests with naked tape and insulating tape in 77 K. The influence of operating temperature on the tape is also studied under subcooled liquid nitrogen condition. For the current impact security of YBCO tape, the critical current degradation and top temperature are analyzed and worked as judgment standards. The testing results is helpful for in developing SFCL in VSC-HVDC.

  20. Micro-assembly of three-dimensional rotary MEMS mirrors

    NASA Astrophysics Data System (ADS)

    Wang, Lidai; Mills, James K.; Cleghorn, William L.

    2009-02-01

    We present a novel approach to construct three-dimensional rotary micro-mirrors, which are fundamental components to build 1×N or N×M optical switching systems. A rotary micro-mirror consists of two microparts: a rotary micro-motor and a micro-mirror. Both of the two microparts are fabricated with PolyMUMPs, a surface micromachining process. A sequential robotic microassembly process is developed to join the two microparts together to construct a threedimensional device. In order to achieve high positioning accuracy and a strong mechanical connection, the micro-mirror is joined to the micro-motor using an adhesive mechanical fastener. The mechanical fastener has self-alignment ability and provides a temporary joint between the two microparts. The adhesive bonding can create a strong permanent connection, which does not require extra supporting plates for the micro-mirror. A hybrid manipulation strategy, which includes pick-and-place and pushing-based manipulations, is utilized to manipulation the micro-mirror. The pick-andplace manipulation has the ability to globally position the micro-mirror in six degrees of freedom. The pushing-based manipulation can achieve high positioning accuracy. This microassembly approach has great flexibility and high accuracy; furthermore, it does not require extra supporting plates, which greatly simplifies the assembly process.

  1. a Self-Excited System for Percussive-Rotary Drilling

    NASA Astrophysics Data System (ADS)

    Batako, A. D.; Babitsky, V. I.; Halliwell, N. A.

    2003-01-01

    A dynamic model for a new principle of percussive-rotary drilling is presented. This is a non-linear mechanical system with two degrees of freedom, in which friction-induced vibration is used for excitation of impacts, which influence the parameters of stick-slip motion. The model incorporates the friction force as a function of sliding velocity, which allows for the self-excitation of the coupled vibration of the rotating bit and striker, which tends to a steady state periodic cycle. The dynamic coupling of vibro-impact action with the stick-slip process provides an entirely new adaptive feature in the drilling process. The dynamic behaviour of the system with and without impact is studied numerically. Special attention is given to analysis of the relationship between the sticking and impacting phase of the process in order to achieve an optimal drilling performance. This paper provides an understanding of the mechanics of percussive -rotary drilling and design of new drilling tools with advanced characteristics. Conventional percussive-rotary drilling requires two independent actuators and special control for the synchronization of impact and rotation. In the approach presented, a combined complex interaction of drill bit and striker is synchronized by a single rotating drive.

  2. Dual traveling wave rotary ultrasonic motor with single active vibrator

    NASA Astrophysics Data System (ADS)

    An, Dawei; Yang, Ming; Zhuang, Xiaoqi; Yang, Tianyue; Meng, Fan; Dong, Zhaopeng

    2017-04-01

    Traveling wave rotary ultrasonic motor with double vibrators can improve the output performance effectively. However, the rotor has to be energized through a slip ring, which increases the complexity and reduces the reliability. Inheriting the concept of two traveling waves propagating in the stator and rotor, a dual traveling wave rotary ultrasonic motor energized only in the stator is proposed. By analyzing the oscillatory differential equation and the contact particles motion, a traveling wave is found in the rotor and the drive mechanism of dual traveling wave is studied. With the resonant rotor adopted, the consistent eigenfrequencies are calculated by finite element method and verified by an impedance analyzer. The performance experiment presents that the dual traveling wave rotary ultrasonic motor is superior to the motor with single traveling wave. The no-load speed is 60 rpm and the stalling torque is 0.85 Nm. Additionally, compared with a reported motor with double vibrators, the proposed motor presents the better output performance and the simpler design.

  3. Robustness of the Rotary Catalysis Mechanism of F1-ATPase*

    PubMed Central

    Watanabe, Rikiya; Matsukage, Yuki; Yukawa, Ayako; Tabata, Kazuhito V.; Noji, Hiroyuki

    2014-01-01

    F1-ATPase (F1) is the rotary motor protein fueled by ATP hydrolysis. Previous studies have suggested that three charged residues are indispensable for catalysis of F1 as follows: the P-loop lysine in the phosphate-binding loop, GXXXXGK(T/S); a glutamic acid that activates water molecules for nucleophilic attack on the γ-phosphate of ATP (general base); and an arginine directly contacting the γ-phosphate (arginine finger). These residues are well conserved among P-loop NTPases. In this study, we investigated the role of these charged residues in catalysis and torque generation by analyzing alanine-substituted mutants in the single-molecule rotation assay. Surprisingly, all mutants continuously drove rotary motion, even though the rotational velocity was at least 100,000 times slower than that of wild type. Thus, although these charged residues contribute to highly efficient catalysis, they are not indispensable to chemo-mechanical energy coupling, and the rotary catalysis mechanism of F1 is far more robust than previously thought. PMID:24876384

  4. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 3 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 6 and 7. The activities from other flight days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). Flight day 6 features a very complicated EVA (extravehicular activity) to service the HST (Hubble Space Telescope). Astronauts Grunsfeld and Linnehan replace the HST's power control unit, disconnecting and reconnecting 36 tiny connectors. The procedure includes the HST's first ever power down. The cleanup of spilled water from the coollant system in Grunsfeld's suit is shown. The pistol grip tool, and two other space tools are also shown. On flight day 7, Newman and Massimino conduct an EVA. They replace the HST's FOC (Faint Object Camera) with the ACS (Advanced Camera for Surveys). The video ends with crew members playing in the shuttle's cabin with a model of the HST.

  5. Visual processing of rotary motion.

    PubMed

    Werkhoven, P; Koenderink, J J

    1991-01-01

    Local descriptions of velocity fields (e.g., rotation, divergence, and deformation) contain a wealth of information for form perception and ego motion. In spite of this, human psychophysical performance in estimating these entities has not yet been thoroughly examined. In this paper, we report on the visual discrimination of rotary motion. A sequence of image frames is used to elicit an apparent rotation of an annulus, composed of dots in the frontoparallel plane, around a fixation spot at the center of the annulus. Differential angular velocity thresholds are measured as a function of the angular velocity, the diameter of the annulus, the number of dots, the display time per frame, and the number of frames. The results show a U-shaped dependence of angular velocity discrimination on spatial scale, with minimal Weber fractions of 7%. Experiments with a scatter in the distance of the individual dots to the center of rotation demonstrate that angular velocity cannot be assessed directly; perceived angular velocity depends strongly on the distance of the dots relative to the center of rotation. We suggest that the estimation of rotary motion is mediated by local estimations of linear velocity.

  6. The ISEE-3 ULEWAT: Flux tape description and heavy ion fluxes 1978-1984. [plasma diagnostics

    NASA Technical Reports Server (NTRS)

    Mason, G. M.; Klecker, B.

    1985-01-01

    The ISEE ULEWAT FLUX tapes contain ULEWAT and ISEE pool tape data summarized over relatively long time intervals (1hr) in order to compact the data set into an easily usable size. (Roughly 3 years of data fit onto one 1600 BPI 9-track magnetic tape). In making the tapes, corrections were made to the ULEWAT basic data tapes in order to, remove rate spikes and account for changes in instrument response so that to a large extent instrument fluxes can be calculated easily from the FLUX tapes without further consideration of instrument performance.

  7. Comparative evaluation of apical extrusion of debris and irrigant with three rotary instruments using crown down technique - An in vitro study.

    PubMed

    Jindal, Rahul; Singh, Smita; Gupta, Siddharth; Jindal, Punita

    2012-01-01

    The purpose of this study was to evaluate and compare the apical extrusion of debris and irrigant using various rotary instruments with crown down technique in the instrumentation of root canals. Thirty freshly extracted human permanent straight rooted mandibular premolars with minimum root curvature of 0-10 ° were divided in three groups with 10 teeth in each group. Each group was instrumented using one of the three rotary instrumentation systems: Rotary Hero shapers, Rotary ProTaper and Rotary Mtwo. One ml of sterile water was used as an irrigant after using each instrument. Debris extruded was collected in pre weighed glass vials and the extruded irrigant was measured quantitatively by Myers and Montgomery method and was later evaporated. The weight of the dry extruded debris was calculated by comparing the pre and post instrumentation weight of glass vials for each group. Statistical analysis was done by using by a Kruskal-Wallis One-way ANOVA test. Statistical analysis showed that all the rotary instruments used in this study caused apical extrusion of debris and irrigant. A Statistically significant difference was observed with Rotary ProTaper and Rotary Mtwo groups when compared with Rotary Hero shapers. But no significant difference was observed between Rotary ProTaper and Rotary Mtwo groups. After instrumentation with different rotary instruments, Hero shapers showed a less apical extrusion of debris and irrigant.

  8. ICI optical data storage tape: An archival mass storage media

    NASA Technical Reports Server (NTRS)

    Ruddick, Andrew J.

    1993-01-01

    At the 1991 Conference on Mass Storage Systems and Technologies, ICI Imagedata presented a paper which introduced ICI Optical Data Storage Tape. This paper placed specific emphasis on the media characteristics and initial data was presented which illustrated the archival stability of the media. More exhaustive analysis that was carried out on the chemical stability of the media is covered. Equally important, it also addresses archive management issues associated with, for example, the benefits of reduced rewind requirements to accommodate tape relaxation effects that result from careful tribology control in ICI Optical Tape media. ICI Optical Tape media was designed to meet the most demanding requirements of archival mass storage. It is envisaged that the volumetric data capacity, long term stability and low maintenance characteristics demonstrated will have major benefits in increasing reliability and reducing the costs associated with archival storage of large data volumes.

  9. Incidence of dentinal defects after root canal preparation: reciprocating versus rotary instrumentation.

    PubMed

    Bürklein, Sebastian; Tsotsis, Polymnia; Schäfer, Edgar

    2013-04-01

    The purpose of this study was to evaluate the incidence of dentinal defects after root canal preparation with reciprocating instruments (Reciproc and WaveOne) and rotary instruments. One hundred human central mandibular incisors were randomly assigned to 5 groups (n = 20 teeth per group). The root canals were instrumented by using the reciprocating single-file systems Reciproc and WaveOne and the full-sequence rotary Mtwo and ProTaper instruments. One group was left unprepared as control. Roots were sectioned horizontally at 3, 6, and 9 mm from the apex and evaluated under a microscope by using 25-fold magnification. The presence of dentinal defects (complete/incomplete cracks and craze lines) was noted and analyzed by using the chi-square test. No defects were observed in the controls. All canal preparation created dentinal defects. Overall, instrumentation with Reciproc was associated with more complete cracks than the full-sequence files (P = .021). Although both reciprocating files produced more incomplete cracks apically (3 mm) compared with the rotary files (P = .001), no statistically significant differences were obtained concerning the summarized values of all cross sections (P > .05). Under the conditions of this study, root canal preparation with both rotary and reciprocating instruments resulted in dentinal defects. At the apical level of the canals, reciprocating files produced significantly more incomplete dentinal cracks than full-sequence rotary systems (P < .05). Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  10. Fabrication of high edge-definition steel-tape gratings for optical encoders.

    PubMed

    Ye, Guoyong; Liu, Hongzhong; Yan, Jiawei; Ban, Yaowen; Fan, Shanjin; Shi, Yongsheng; Yin, Lei

    2017-10-01

    High edge definition of a scale grating is the basic prerequisite for high measurement accuracy of optical encoders. This paper presents a novel fabrication method of steel tape gratings using graphene oxide nanoparticles as anti-reflective grating strips. Roll-to-roll nanoimprint lithography is adopted to manufacture the steel tape with hydrophobic and hydrophilic pattern arrays. Self-assembly technology is employed to obtain anti-reflective grating strips by depositing the graphene oxide nanoparticles on hydrophobic regions. A thin SiO 2 coating is deposited on the grating to protect the grating strips. Experimental results confirm that the proposed fabrication process enables a higher edge definition in making steel-tape gratings, and the new steel tape gratings offer better performance than conventional gratings.

  11. Fabrication of high edge-definition steel-tape gratings for optical encoders

    NASA Astrophysics Data System (ADS)

    Ye, Guoyong; Liu, Hongzhong; Yan, Jiawei; Ban, Yaowen; Fan, Shanjin; Shi, Yongsheng; Yin, Lei

    2017-10-01

    High edge definition of a scale grating is the basic prerequisite for high measurement accuracy of optical encoders. This paper presents a novel fabrication method of steel tape gratings using graphene oxide nanoparticles as anti-reflective grating strips. Roll-to-roll nanoimprint lithography is adopted to manufacture the steel tape with hydrophobic and hydrophilic pattern arrays. Self-assembly technology is employed to obtain anti-reflective grating strips by depositing the graphene oxide nanoparticles on hydrophobic regions. A thin SiO2 coating is deposited on the grating to protect the grating strips. Experimental results confirm that the proposed fabrication process enables a higher edge definition in making steel-tape gratings, and the new steel tape gratings offer better performance than conventional gratings.

  12. Rotary wave-ejector enhanced pulse detonation engine

    NASA Astrophysics Data System (ADS)

    Nalim, M. R.; Izzy, Z. A.; Akbari, P.

    2012-01-01

    The use of a non-steady ejector based on wave rotor technology is modeled for pulse detonation engine performance improvement and for compatibility with turbomachinery components in hybrid propulsion systems. The rotary wave ejector device integrates a pulse detonation process with an efficient momentum transfer process in specially shaped channels of a single wave-rotor component. In this paper, a quasi-one-dimensional numerical model is developed to help design the basic geometry and operating parameters of the device. The unsteady combustion and flow processes are simulated and compared with a baseline PDE without ejector enhancement. A preliminary performance assessment is presented for the wave ejector configuration, considering the effect of key geometric parameters, which are selected for high specific impulse. It is shown that the rotary wave ejector concept has significant potential for thrust augmentation relative to a basic pulse detonation engine.

  13. A 16-channel cassette tape recorder system for clinical EEGs.

    PubMed

    Barlow, J S

    1975-02-01

    A 16-channel EEG tape recorder system having a frequency response of DC-100 Hz for each channel is described. The system utilized standard commercially available highfidelity audio tape decks in conjunction with specially designed circuits for time-division multiplexing a balanced amplitude modulation

  14. Rotary Joints With Electrical Connections

    NASA Technical Reports Server (NTRS)

    Osborn, F. W.

    1986-01-01

    Power and data transmitted on many channels. Two different rotary joints equipped with electrical connections between rotating and stationary parts. One joint transmits axial thrust and serves as interface between spinning and nonspinning parts of Galileo spacecraft. Other is scanning (limitedrotation) joint that aims scientific instruments from nonspinning part. Selected features of both useful to designers of robots, advanced production equipment, and remotely controlled instruments.

  15. A novel perfused rotary bioreactor for cardiomyogenesis of embryonic stem cells.

    PubMed

    Teo, Ailing; Mantalaris, Athanasios; Song, Kedong; Lim, Mayasari

    2014-05-01

    Developments in bioprocessing technology play an important role for overcoming challenges in cardiac tissue engineering. To this end, our laboratory has developed a novel rotary perfused bioreactor for supporting three-dimensional cardiac tissue engineering. The dynamic culture environments provided by our novel perfused rotary bioreactor and/or the high-aspect rotating vessel produced constructs with higher viability and significantly higher cell numbers (up to 4 × 10(5) cells/bead) than static tissue culture flasks. Furthermore, cells in the perfused rotary bioreactor showed earlier gene expressions of cardiac troponin-T, α- and β-myosin heavy chains with higher percentages of cardiac troponin-I-positive cells and better uniformity of sacromeric α-actinin expression. A dynamic and perfused environment, as provided by this bioreactor, provides a superior culture performance in cardiac differentiation for embryonic stem cells particularly for larger 3D constructs.

  16. Storage, Preservation, and Recovery of Magnetic Recording Tape

    NASA Technical Reports Server (NTRS)

    Cuddihy, Edward F.

    1994-01-01

    During the 1970's, a commercial magnetic recording tape fabricated with magnetic oxide particles, and with oxide and backcoat binders made from polyester urethane was being used for spacecraft tape recorders, and which would periodically manifest operational problems such as layer-to-layer adhesion, stick-slip, and shedding of sticky organic materials. These problems were generally associated with periods of high humidity. An experimental study identified that these problems resulted from hydrolysis of the polyester urethane binders.

  17. Ultrasound assessment of tension-free vaginal tape (TVT).

    PubMed

    Flock, F; Kohorst, F; Kreienberg, R; Reich, A

    2011-01-01

    To date, no standardization for the visualization of tension-free vaginal tape (TVT) has been established in clinical practice. The aim of this prospective observational study was to evaluate the shape and position of the tape using ultrasound and to compare this data with clinical postoperative results. In a three-year period, 296 patients with clinically and urodynamically proven stress urinary incontinence (SUI) were treated with TVT and received follow-up in our department. An additional 12 patients, who were initially treated in other hospitals and had postoperative problems, were included in this study. Depending on the outcome after 3 months, the patients were divided into groups with and without specific disorders. The TVT was evaluated by introital ultrasound. The position of the tape was established by its location in relation to the urethral length and the distance to the hypoechoic center of the urethra (HCU). A suitable TVT position was determined in patients without any postoperative disorders. The mean value for the TVT position at rest in relation to the urethral length was 61 %. The distance to the HCU was 4.6 ± 1.5 mm. In patients with persistent SUI, the tape was more often located under the inner (3 % vs. 0 %) or outer quarter (29 % vs. 13 %, p = 0.004). In patients with residual volume, the distance to the urethra was significantly lower (2.7 vs. 4.6, p < 0.001). TVT may be regularly investigated using ultrasound. In combination with the clinical outcome, it represents an important method of evaluating the tape and assists in the planning of a future therapeutic course of action in cases of postoperative problems. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Compression in wearable sensor nodes: impacts of node topology.

    PubMed

    Imtiaz, Syed Anas; Casson, Alexander J; Rodriguez-Villegas, Esther

    2014-04-01

    Wearable sensor nodes monitoring the human body must operate autonomously for very long periods of time. Online and low-power data compression embedded within the sensor node is therefore essential to minimize data storage/transmission overheads. This paper presents a low-power MSP430 compressive sensing implementation for providing such compression, focusing particularly on the impact of the sensor node architecture on the compression performance. Compression power performance is compared for four different sensor nodes incorporating different strategies for wireless transmission/on-sensor-node local storage of data. The results demonstrate that the compressive sensing used must be designed differently depending on the underlying node topology, and that the compression strategy should not be guided only by signal processing considerations. We also provide a practical overview of state-of-the-art sensor node topologies. Wireless transmission of data is often preferred as it offers increased flexibility during use, but in general at the cost of increased power consumption. We demonstrate that wireless sensor nodes can highly benefit from the use of compressive sensing and now can achieve power consumptions comparable to, or better than, the use of local memory.

  19. Broadband rotary joint for high speed ultrahigh resolution endoscopic OCT imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Alemohammad, Milad; Yuan, Wu; Mavadia-Shukla, Jessica; Liang, Wenxuan; Yu, Xiaoyun; Yu, Shaoyong; Li, Xingde

    2016-03-01

    Endoscopic OCT is a promising technology enabling noninvasive in vivo imaging of internal organs, such as the gastrointestinal tract and airways. The past few years have witnessed continued efforts to achieve ultrahigh resolution and speed. It is well-known that the axial resolution in OCT imaging has a quadratic dependence on the central wavelength. While conventional OCT endoscopes operate in 1300 nm wavelength, the second-generation endoscopes are designed for operation around 800 nm where turn-key, broadband sources are becoming readily available. Traditionally 1300 nm OCT endoscopes are scanned at the proximal end, and a broadband fiber-optic rotary joint as a key component in scanning endoscopic OCT is commercially available. Bandwidths in commercial 800 nm rotary joints are unfortunately compromised due to severe chromatic aberration, which limits the resolution afforded by the broadband light source. In the past we remedied this limitation by using a home-made capillary-tube-based rotary joint where the maximum reliable speed is ~10 revolutions/second. In this submission we report our second-generation, home-built high-speed and broadband rotary joint for 800 nm wavelength, which uses achromatic doublets in order achieve broadband achromatic operation. The measured one-way throughput of the rotary joint is >67 % while the fluctuation of the double-pass coupling efficiency during 360° rotation is less than +/-5 % at a speed of 70 revolutions/second. We demonstrate the operation of this rotary joint in conjunction with our ultrahigh-resolution (2.4 µm in air) diffractive catheter by three-dimensional full-circumferential endoscopic imaging of guinea pig esophagus at 70 frames per second in vivo.

  20. Burnout Test of First- and Second-Generation HTS Tapes in Liquid-Nitrogen Bath Cooling

    NASA Astrophysics Data System (ADS)

    Young, M. A.; Demko, J. A.; Duckworth, R. C.; Lue, J. W.; Gouge, M. J.; Pace, M. O.

    2004-06-01

    A series of BSCCO-2223 and YBCO tapes were subjected to burnout tests in a liquid-nitrogen bath to observe operational stability limits when different layers of dielectric tape are added to the sample surface. In this study, the BSCCO tapes were composed of a silver/alloy sheath with nickel/copper plating, while the YBCO tapes had a 50-μm layer of copper attached to the silver surface. After attaching the tapes to a thermally insulated G-10 holder, the stability of the tapes was found by applying current greater than the critical current and holding it constant for up to 1 min. If the sample voltage increased rapidly during this period, the tape was considered unstable at this current. This was repeated at different layers of Cryoflex™, and the results were compared to a numerical simulation of the energy balance equation. This simulation was also utilized to investigate the effect of the layers on the stability limit and estimate the thermal conductivity of the Cryoflex™.

  1. Scalable Node Monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drotar, Alexander P.; Quinn, Erin E.; Sutherland, Landon D.

    2012-07-30

    Project description is: (1) Build a high performance computer; and (2) Create a tool to monitor node applications in Component Based Tool Framework (CBTF) using code from Lightweight Data Metric Service (LDMS). The importance of this project is that: (1) there is a need a scalable, parallel tool to monitor nodes on clusters; and (2) New LDMS plugins need to be able to be easily added to tool. CBTF stands for Component Based Tool Framework. It's scalable and adjusts to different topologies automatically. It uses MRNet (Multicast/Reduction Network) mechanism for information transport. CBTF is flexible and general enough to bemore » used for any tool that needs to do a task on many nodes. Its components are reusable and 'EASILY' added to a new tool. There are three levels of CBTF: (1) frontend node - interacts with users; (2) filter nodes - filters or concatenates information from backend nodes; and (3) backend nodes - where the actual work of the tool is done. LDMS stands for lightweight data metric servies. It's a tool used for monitoring nodes. Ltool is the name of the tool we derived from LDMS. It's dynamically linked and includes the following components: Vmstat, Meminfo, Procinterrupts and more. It works by: Ltool command is run on the frontend node; Ltool collects information from the backend nodes; backend nodes send information to the filter nodes; and filter nodes concatenate information and send to a database on the front end node. Ltool is a useful tool when it comes to monitoring nodes on a cluster because the overhead involved with running the tool is not particularly high and it will automatically scale to any size cluster.« less

  2. Tape casting and partial melting of Bi-2212 thick films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buhl, D.; Lang, T.; Heeb, B.

    1994-12-31

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 {mu}m. The orientation of the (a,b)-plane of the grains were parallel to the substrate with a misalignment of less than 6{degrees}. At 77K/OT a critical current density ofmore » 15`000 A/cm{sup 2} was reached in films of the dimension 1cm x 2cm x 20{mu}m (1{mu}V/cm criterion, resistively measured). At 4K/OT the highest value was 350`000 A/cm{sup 2} (1nV/cm criterion, magnetically measured).« less

  3. Flux pinning in nanoparticle doped MgB 2/Cu tapes

    NASA Astrophysics Data System (ADS)

    Babić, E.; Kušević, I.; Husnjak, O.; Soltanian, S.; Wang, X. L.; Dou, S. X.

    2007-09-01

    The irreversibility fields Birr and critical current densities Jc of undoped and Si and SiC nanoparticle doped (5, 10 and 20 wt%) MgB2 tapes were measured in the temperature (T) range 2-38 K and in magnetic fields B ⩽ 16 T. Whereas Birr of undoped tapes varies smoothly with T, those of doped tapes show a change in slope around a crossover field Bcr which increases with nanoparticle content and also depends on their type. This indicates matching effect in vortex pinning, probably associated with Mg2Si nanoprecipitates formed during heat treatment. Indeed, Birr of doped tapes was enhanced in respect to that of undoped one with the highest enhancement for Birr ≈ Bcr, but the enhancement remained high ≈1.4 even for Birr ≫ Bcr (low temperatures). The variations of Jc and the pinning force density Fp = JcB with B and T support the above findings.

  4. Tape casting and partial melting of Bi-2212 thick films

    NASA Technical Reports Server (NTRS)

    Buhl, D.; Lang, TH.; Heeb, B.; Gauckler, L. J.

    1995-01-01

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 microns. The orientation of the (a,b)-plane of the grains was parallel to the substrate with a misalignment of less than 6 deg. At 77 K/0T a critical current density of 15, 000 A/sq cm was reached in films of the dimension 1 cm x 2 cm x 20 microns (1 micron V/cm criterion, resistively measured). At 4 K/0T the highest value was 350,000 A/sq cm (1 nV/cm criterion, magnetically measured).

  5. Generation and physical characteristics of the Landsat 1 and 2 MSS computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1975-01-01

    The generation and format is discussed of the Landsat 1 and 2 system corrected multispectral scanner computer compatible tapes. Included in the discussion are the spacecraft sensors, scene characteristics, the transmission of data, and the conversion of the data to computer compatible tapes at the NASA Data Processing Facility. Geometric and radiometric corrections, tape formats, and the physical characteristics of the tape are also described.

  6. Influence of TVT properties on outcomes of midurethral sling procedures: high-stiffness versus low-stiffness tape.

    PubMed

    Prien-Larsen, Jens Christian; Prien-Larsen, Thomas; Cieslak, Lars; Dessau, Ram B

    2016-07-01

    Although there is clear consensus on the use of monofilament polypropylene tapes for treating stress urinary incontinence (SUI), tapes differ in weight, stiffness, and elasticity. In this study, we compared outcomes of two tape types: high-stiffness Intramesh SOFT L.I.F.T versus low-stiffness Intramesh L.I.F.T. tape. Our null hypothesis was that in terms of performance, SOFT tape equaled L.I.F.T. tape. Six hundred and sixty women underwent prospective transvaginal tape (TVT) surgery for SUI: 210 had the SOFT tape placed and 450 the L.I.F.T. tape. Follow-ups were scheduled at 3 and 12 months. Objective cure at 3-months' follow-up was 87 % in the SOFT group vs 94 % in the L.I.F.T. group (p = 0.003) and at 12 months 86 vs 96 % (p = 0.0004), respectively. Subjective outcomes were equal. For SOFT tape, the objective failure rate at 3 months was especially pronounced in women older than 70 years: 31 vs 10 % (p = 0.008), and subjective failure was 24 vs 7 % (p = 0.01). At 12 months, objective failure for the SOFT tape was significantly higher in both age groups compared with L.I.F.T. [odds ratio (OR) 2.17]. Multivariate analysis showed that body mass index (BMI) ≥30 (OR 2.41), mixed incontinence (MUI) (OR 2.24), use of SOFT tape (OR 2.17), and age ≥ 70 years are significant independent risk factors for surgical failure. Outcomes with SOFT tape are significantly inferior than with L.I.F.T. tape, especially among elderly women. Therefore, the two variants of monofilament polypropylene tape are not interchangeable.

  7. JPL Ephemeris Tapes E9510, E9511, and E9512

    NASA Technical Reports Server (NTRS)

    Peabody, P. R.; Scott, J. F.; Orozco, E. G.

    1964-01-01

    The first issue of JPL Ephemeris Tapes is described. These tapes carry the positions and velocities of the planets and of the Moon, plus nutations and nutation rates in longitude and obliquity, together with second and fourth modified differences, for the interval December 30, 1949, to January 5, 2000.

  8. Geometric analysis of maxillary first premolar prepared by two nickel-titanium rotary instruments.

    PubMed

    Al-Sudani, Dina; Almalki, Majed; Al-Shahrani, Saad; Ahlquist, Michael

    2014-03-01

    The present study was conducted with the aim of evaluating and comparing the shaping ability of two Nickel-titanium rotary instruments, with two disparate design features, on root canal geometry of extracted human maxillary first premolars using microcomputed tomography. Twenty four bifurcated maxillary first premolars were divided into two groups and embedded in a rubber-based impression material. Both groups were submitted to micro-computed tomography before and after canal preparation (buccal and palatal) with either ProFile Vortex or Revo-S rotary instruments. Images were reconstructed and cross-sections corresponding to a distance 1, 2, 3, 4, 5, 6, and 7 mm from the anatomical apex were selected for canal transportation analysis. Volume changes were also measured. The degree and direction of canal transportation were non-significant for both instruments. Statistically significant differences were observed only between levels in the buccal canal in both groups. There was no significant difference between the two rotary systems in regards to the volume of dentin removed. Our findings showed that ProFile Vortex and Revo-S instruments respected the original root canal anatomy and behaved similarly. ProFile Vortex rotary systems produced with innovative process were concluded to shape the upper maxillary premolar by leading minimal canal transportation, similar to Revo-S, rotary systems produced from traditional process.

  9. Development of a natural gas stratified charge rotary engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sierens, R.; Verdonck, W.

    A water model has been used to determine the positions of separate inlet ports for a natural gas, stratified charge rotary engine. The flow inside the combustion chamber (mainly during the induction period) has been registered by a film camera. From these tests the best locations of the inlet ports have been obtained, a prototype of this engine has been built by Audi NSU and tested in the laboratories of the university of Gent. The results of these tests, for different stratification configurations, are given. These results are comparable with the best results obtained by Audi NSU for a homogeneousmore » natural gas rotary engine.« less

  10. High current density electropolishing in the preparation of highly smooth substrate tapes for coated conductors

    DOEpatents

    Kreiskott, Sascha [Los Alamos, NM; Matias, Vladimir [Santa Fe, NM; Arendt, Paul N [Los Alamos, NM; Foltyn, Stephen R [Los Alamos, NM; Bronisz, Lawrence E [Los Alamos, NM

    2009-03-31

    A continuous process of forming a highly smooth surface on a metallic tape by passing a metallic tape having an initial roughness through an acid bath contained within a polishing section of an electropolishing unit over a pre-selected period of time, and, passing a mean surface current density of at least 0.18 amperes per square centimeter through the metallic tape during the period of time the metallic tape is in the acid bath whereby the roughness of the metallic tape is reduced. Such a highly smooth metallic tape can serve as a base substrate in subsequent formation of a superconductive coated conductor.

  11. Detection of latent fingerprint hidden beneath adhesive tape by optical coherence tomography.

    PubMed

    Zhang, Ning; Wang, Chengming; Sun, Zhenwen; Li, Zhigang; Xie, Lanchi; Yan, Yuwen; Xu, Lei; Guo, Jingjing; Huang, Wei; Li, Zhihui; Xue, Jing; Liu, Huan; Xu, Xiaojing

    2018-06-01

    Adhesive tape is one type of common item which can be encountered in criminal cases involving rape, murder, kidnapping and explosives. It is often the case that a suspect deposits latent fingerprints on the sticky side of adhesive tape material when tying up victims, manufacturing improvised explosive devices or packaging illegal goods. However, the adhesive tapes found at crime scenes are usually stuck together or attached to a certain substrate, and thus the latent fingerprints may be hidden beneath the tapes. Current methods to detect latent fingerprint hidden beneath adhesive tape need to peel it off first and then apply physical or chemical methods to develop the fingerprint, which undergo complicated procedures and would affect the original condition of latent print. Optical coherence tomography (OCT) is a novel applied techniques in forensics which enables obtaining cross-sectional structure with the advantages of non-invasive, in-situ, high resolution and high speed. In this paper, a custom-built spectral-domain OCT (SD-OCT) system with a hand-held probe was employed to detect fingerprints hidden beneath different types of adhesive tapes. Three-dimensional (3D) OCT reconstructions were performed and the en face images were presented to reveal the hidden fingerprints. The results demonstrate that OCT is a promising tool for rapidly detecting and recovering high quality image of latent fingerprint hidden beneath adhesive tape without any changes to the original state and preserve the integrity of the evidence. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Compact fast analyzer of rotary cuvette type

    DOEpatents

    Thacker, Louis H.

    1976-01-01

    A compact fast analyzer of the rotary cuvette type is provided for simultaneously determining concentrations in a multiplicity of discrete samples using either absorbance or fluorescence measurement techniques. A rigid, generally rectangular frame defines optical passageways for the absorbance and fluorescence measurement systems. The frame also serves as a mounting structure for various optical components as well as for the cuvette rotor mount and drive system. A single light source and photodetector are used in making both absorbance and fluorescence measurements. Rotor removal and insertion are facilitated by a swing-out drive motor and rotor mount. BACKGROUND OF THE INVENTION The invention relates generally to concentration measuring instruments and more specifically to a compact fast analyzer of the rotary cuvette type which is suitable for making either absorbance or fluorescence measurements. It was made in the course of, or under, a contract with the U.S. Atomic Energy Commission.

  13. Development of natural gas rotary engines

    NASA Astrophysics Data System (ADS)

    Mack, J. R.

    1991-08-01

    Development of natural gas-fueled rotary engines was pursued on the parallel paths of converted Mazda automotive engines and of establishing technology and demonstration of a test model of a larger John Deer Technologies Incorporated (JDTI) rotary engine with power capability of 250 HP per power section for future production of multi-rotor engines with power ratings 250, 500, and 1000 HP and upward. Mazda engines were converted to natural gas and were characterized by a laboratory which was followed by nearly 12,000 hours of testing in three different field installations. To develop technology for the larger JDTI engine, laboratory and engine materials testing was accomplished. Extensive combustion analysis computer codes were modified, verified, and utilized to predict engine performance, to guide parameters for actual engine design, and to identify further improvements. A single rotor test engine of 5.8 liter displacement was designed for natural gas operation based on the JDTI 580 engine series. This engine was built and tested. It ran well and essentially achieved predicted performance. Lean combustion and low NOW emission were demonstrated.

  14. The Influence of the Tape-Recorder on Attainment in EFL.

    ERIC Educational Resources Information Center

    Al-Ansari, Saif; Wigzell, Roy

    1996-01-01

    Reports a study undertaken in Bahrain secondary schools to assess the contribution of tape recorders to learning outcomes in English as a Second Language (ESL). Findings revealed that students' proficiency correlated significantly with their perception of the frequency and skill with which their teacher use a tape recorder. (20 references)…

  15. Advanced liquid-cooled, turbocharged and intercooled stratified charge rotary engines for aircraft

    NASA Technical Reports Server (NTRS)

    Mount, Robert E.; Bartel, John; Hady, William F.

    1987-01-01

    Developments concerning stratified-charge rotary (SCR) engines over the past 10 years are reviewed. Aircraft engines being developed using SCR technology are shown and described, and the ability of such technology to meet general aviation engine needs is considered. Production timing and availability of SCR technology for the development of aviation rotary engines are discussed, and continuing efforts toward improving this technology, including NASA efforts, are described.

  16. 41 CFR 101-26.508-2 - Requisitioning data processing tape not available from Federal Supply Schedule contracts.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... contracts. (a) Requisitions for types of EDP tape and instrumentation tape (wide and intermediate band... is located. (b) Requisitions for all types of EDP tape and instrumentation tape (wide and... and $5,000 for instrumentation tape. However, regardless of the amount involved (including...

  17. Age-of-Air, Tape Recorder, and Vertical Transport Schemes

    NASA Technical Reports Server (NTRS)

    Lin, S.-J.; Einaudi, Franco (Technical Monitor)

    2000-01-01

    A numerical-analytic investigation of the impacts of vertical transport schemes on the model simulated age-of-air and the so-called 'tape recorder' will be presented using an idealized 1-D column transport model as well as a more realistic 3-D dynamical model. By comparing to the 'exact' solutions of 'age-of-air' and the 'tape recorder' obtainable in the 1-D setting, useful insight is gained on the impacts of numerical diffusion and dispersion of numerical schemes used in global models. Advantages and disadvantages of Eulerian, semi-Lagrangian, and Lagrangian transport schemes will be discussed. Vertical resolution requirement for numerical schemes as well as observing systems for capturing the fine details of the 'tape recorder' or any upward propagating wave-like structures can potentially be derived from the 1-D analytic model.

  18. The Ergogenic Effect of Elastic Therapeutic Tape on Stride and Step Length in Fatigued Runners

    PubMed Central

    Ward, John; Sorrels, Kenneth; Coats, Jesse; Pourmoghaddam, Amir; Moskop, JoAnn; Ueckert, Kate; Glass, Amanda

    2014-01-01

    Objective The purpose of this study was to determine if elastic therapeutic tape placed on anterior lower limbs would affect stride and step length in fatigued runners’ gait. Methods Forty-two healthy participants were equally divided into a kinesiology tape group (Rocktape) and a no-tape control group. Participants in both groups underwent a baseline running gait test at 6 mph without tape. After this, participants engaged in an exhaustive lower body fatigue protocol until they reached maximal volitional exhaustion. Participants were then randomized to 1 of 2 interventions: (1) Experimental group, which had kinesiology tape placed under tension on the anterior aspect of their lower limbs bilaterally from the upper thigh to just below the patella, or (2) Control group, which did not receive taping. All participants then engaged in a similar 6-mph running gait postanalysis. Participant’s gait was analyzed for 90 seconds during each test iteration. Researchers used a 2-way repeated-measures analysis of variance considering fatigue (prefatigue, postfatigue) and group (tape, no-tape) as subject factors. Results After the fatigue protocol, the no-tape group demonstrated a significant decrease in step length of 14.2 mm (P = .041) and stride length of 29.4 mm (P = .043). The kinesiology tape group did not demonstrate a significant decline in these gait parameters. Conclusions In this preliminary study, placing elastic therapeutic tape over the anterior lower limbs demonstrated short-term preservation of runner step length and stride length in a fatigued state. PMID:25435835

  19. Evaluation of a new silicone adhesive tape among clinicians caring for patients with fragile or at-risk skin.

    PubMed

    Manriquez, Sonia; Loperfido, Bonnie; Smith, Graham

    2014-04-01

    To evaluate performance of a new silicone tape among clinicians caring for patients with fragile skin. An international, multisite, 2-week-use evaluation. Caregivers (n = 217) from acute care hospitals in the United States, United Kingdom, and France who regularly use tapes on patients with fragile skin. The silicone tape was substituted for current-use gentle tapes for a 2-week trial period. Preuse and postuse questionnaires were collected. The main outcome measure was tape preference. Secondary outcomes included (1) satisfaction with current-use tapes, (2) willingness to replace current-use tapes with silicone tape, (3) performance comparisons between tapes, (4) clinician-reported problems with the silicone tape, and (5) case study information. The sample group consisted of nurses (98.1%), assistants (1.4%), and physicians (0.5%). Hospital units (n = 100) included oncology (31%), medical-surgical (14%), dialysis (12%), infusion/intravenous therapy (16%), critical care (10%), wound care (10%), and other units (7%). Overall preference was 92.0% for the silicone tape, 7.5% for current-use tapes, and 0.5% no preference. Dissatisfaction was 61.2% for current-use tapes, and most clinicians (90.2%) would change to the silicone tape. Evaluators favored (≥71.5%) the silicone tape on 10 performance attributes and on overall performance (91.6%). Most evaluators (75.1%) did not experience problems with the silicone tape, and those who did found problems related to adhesion (77.8%), gentleness (16.0%), and residue (6.2%). These results indicate that the silicone tape fills a performance-expectation gap of current acrylic tapes among users of tapes on patients with fragile or at-risk skin.

  20. Thermal chemical vapor deposition (T-CVD) growth of carbon nanotubes on different metallic underlayers

    NASA Astrophysics Data System (ADS)

    Kim, S. M.; Gangloff, L.

    2011-06-01

    The synthesis of carbon nanotubes (CNTs) on various substrates by thermal chemical vapor deposition (T-CVD) (500-800 °C) is described. C 2H 2 (98% purity) is used as the carbon feedstock and the metallic underlayers, i.e., AlCu, Cu, Ag, Ta, and NiV are used. A crucial component is the insertion (or inclusion) of an Al layer between the metal and the catalyst, which then leads to the effective growth of CNTs. The types of CNTs (single or multi walled) could be dependent on the diameter of Al xO y nanoparticles that are formed during the annealing process. In situ mass spectroscopy reveals that the increase in CO 2 and H 2O with temperature, during the growth, could be correlated to the formation of longer CNTs (∼2 μm) on NiV and Ta due to their etching effects (i.e. C+CO 2→2CO and C+H 2O→CO+H 2).

  1. Coal desulfurization in a rotary kiln combustor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cobb, J.T. Jr.

    1991-04-22

    The focus of our work during the first quarter of 1991 was on combustion tests at the PEDCO rotary kiln reactor at North American Rayon (NARCO) plant in Elizabethton, TN. The tests had essentially tow related objectives: (a) to obtain basic data on the combustion of anthracite culm in a rotary kiln reactor, and (b) upon the test results, determine how best to proceed with our own planned program at the Humphrey Charcoal kiln in Brookville, PA. The rationale for the tests at PEDCO arose from process analysis which posted red flags on the feasibility of burning low-grade, hard-to-burn fuelsmore » like anthracite culms, in the rotary kiln. The PEDCO unit afforded a unique opportunity to obtain some quick answers at low cost. Two different anthracite culm fuels were tested: a so-called Jeddo culm with an average heating value of 7000 Btu/lb, and a relatively poorer culm, and Emerald'' culm, with an average heating value of 5000 Btu/lb. An attempt was also made to burn a blend of the Emerald culm with bituminous coal in 75/25 percent proportions. This report describes the tests, their chronology, and preliminary results. As it turned out, the PEDCO unit is not configured properly for the combustion of anthracite culm. As a result, it proved difficult to achieve a sustained period of steady-state combustion operation, and combustion efficiencies were low even when supplemental fuel was used to aid combustion of the culm. 1 fig., 2 tabs.« less

  2. Tape functionality: position, change in shape, and outcome after TVT procedure--mid-term results.

    PubMed

    Kociszewski, Jacek; Rautenberg, Oliver; Kolben, Sebastian; Eberhard, Jakob; Hilgers, Reinhard; Viereck, Volker

    2010-07-01

    This study evaluates the relevance of the tape position and change in shape (tape functionality) under in vivo conditions for mid-term outcome. Changes in the sonographic tension-free vaginal tape (TVT) position relative to the percentage urethral length and the tape-urethra distance were determined after 6 and 48 months in 41 women with stress urinary incontinence. At 48 months, 76% (31/41) of women were cured, 17% (7/41) were improved, and 7% (3/41) were failures. Disturbed bladder voiding was present in 12% (5/41), de novo urge incontinence in 7% (3/41). The median TVT position was at 63% of urethral length. Median tape-urethra distance was 2.7 mm, ranging from 2.9 mm in continent patients without complications to 1.1 mm in those with obstructive complications. Patients with postoperative urine loss had a median distance of 3.9 mm. The tape was stretched at rest and C-shaped during straining in 15 of 41 women (37%) at 48 months (all continent). Patients with this tape functionality at 6 months were also cured at 48 months in 86% of cases (19/22), and only 14% (3/22) showed recurrent incontinence. Mid-term data suggest an optimal outcome if the tape is positioned at least 2 mm from the urethra at the junction of the middle and distal thirds. Patients with optimal tape functionality at 6 months are likely to show mid-term therapeutic success.

  3. Use of adhesive surgical tape with the absorbable continuous subcuticular suture.

    PubMed

    Kolt, Jeremy D

    2003-08-01

    The absorbable continuous subcuticular suture is frequently used to close surgical incisions where the aim is healing by primary intention. A form of adhesive surgical tape is commonly also placed over the wound but this combination closure seems to have its development based on anecdotal, rather than experimental evidence. The present study reviews the scientific literature on the development of sutureless wound closure and presents the current evidence for the use of combination wound closure. Review was undertaken of the medical literature using the PubMed Internet database and cross-referencing major -articles on the subject. The following combinations of key words were searched: skin closure, wound closure, suture technique, sutureless, adhesive tape, op-site, staples, subcuticular suture, complication, infection and scars. Taped closure alone has advantages of lower wound infection rates and greater wound tensile strength, but disadvantages of epidermal reaction, skin edge inversion, doubtful safety and time required for meticulous surgical technique. The use of the continuous absorbable subcuticular suture allows accurate skin edge approximation, which increases the safety margin. The combination closure has a slightly superior cosmetic result to sutureless techniques but no study has been performed to compare the results of combination subcuticular suture and tape, with tape or subcuticular suture alone. There is no evidence in the scientific literature to justify or support the practice of closing a surgical wound with both subcuticular suture and adhesive surgical tape.

  4. Glide path preparation in S-shaped canals with rotary pathfinding nickel-titanium instruments.

    PubMed

    Ajuz, Natasha C C; Armada, Luciana; Gonçalves, Lucio S; Debelian, Gilberto; Siqueira, José F

    2013-04-01

    This study compared the incidence of deviation along S-shaped (double-curved) canals after glide path preparation with 2 nickel-titanium (NiTi) rotary pathfinding instruments and hand K-files. S-shaped canals from 60 training blocks were filled with ink, and preinstrumentation images were obtained by using a stereomicroscope. Glide path preparation was performed by an endodontist who used hand stainless steel K-files (up to size 20), rotary NiTi PathFile instruments (up to size 19), or rotary NiTi Scout RaCe instruments (up to size 20). Postinstrumentation images were taken by using exactly the same conditions as for the preinstrumentation images, and both pictures were superimposed. Differences along the S-shaped canal for the mesial and distal aspects were measured to evaluate the occurrence of deviation. Intragroup analysis showed that all instruments promoted some deviation in virtually all levels. Overall, regardless of the group, deviations were observed in the mesial wall at the canal terminus and at levels 4, 5, 6 and 7 mm and in the distal wall at levels 1, 2, and 3 mm. These levels corresponded to the inner walls of each curvature. Both rotary NiTi instruments performed significantly better than hand K-files at all levels (P < .05), except for PathFiles at the 0-mm level. ScoutRaCe instruments showed significantly better results than PathFiles at levels 0, 2, 3, 5, and 6 mm (P < .05). Findings suggest that rotary NiTi instruments are suitable for adequate glide path preparation because they promoted less deviation from the original canal anatomy when compared with hand-operated instruments. Of the 2 rotary pathfinding instruments, Scout RaCe showed an overall significantly better performance. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  5. DRIFT POTENTIAL OF TILTED SHIELDED ROTARY ATOMISERS BASED ON WIND TUNNEL MEASUREMENTS.

    PubMed

    Salah, S Ouled Taleb; Massinon, M; De Cock, N; Schiffers, B; Lebeau, F

    2015-01-01

    Crop protection is mainly achieved by applying Plant Protection Products (PPP) using hydraulic nozzles, which rely on pressure, to produce a wide droplet size distribution. Because of always increased concerns about drift reduction, a wider range of low drift nozzles, such as air induction nozzles, was adopted in order to reduce the finest part of the spray. While successful for some treatments, the efficiency of coarser sprays is dramatically reduced on small and superhydrophobic target, i.e. at early stage weed control. This may be related to the increased proportion of big bouncing and splashing droplets. On the other hand, Controlled Droplet Application (CDA), using shielded rotary atomizers, stands for an improved control of droplets diameters and trajectories compared to hydraulic nozzles. Unfortunately, these atomizers, because of their horizontal droplet release, are widely recognized to produce more drift than hydraulic nozzles. The present contribution investigates whether the setting of a rotary atomizer 60 degrees forward tilted can reduce drift to acceptable levels in comparison with vertical and 60 degrees forward tilted standard and low drift flat fan nozzles for the same flow rate. In a wind tunnel, the drift potential of a medium spray produced by a tilted shielded rotary atomizer Micromax 120 was benchmarked with that of a flat fan nozzle XR11002 fine spray and that of an anti-drift nozzle Hardi Injet 015 medium spray. Operating parameters were set to apply 0.56 l/min for every spray generator. Vertical drift profiles were measured 2.0 m downward from nozzle axis for a 2 m.s(-1) wind speed. The tilted hydraulic nozzles resulted in a significant drift increase while droplets trajectories are affected by the decrease of the droplet initial vertical speed. Droplets emitted by the shielded rotary atomizer drift due to low entrained air and turbulence. A significant reduction of the cumulative drift was achieved by the rotary atomizer in comparison

  6. Math modeling and computer mechanization for real time simulation of rotary-wing aircraft

    NASA Technical Reports Server (NTRS)

    Howe, R. M.

    1979-01-01

    Mathematical modeling and computer mechanization for real time simulation of rotary wing aircraft is discussed. Error analysis in the digital simulation of dynamic systems, such as rotary wing aircraft is described. The method for digital simulation of nonlinearities with discontinuities, such as exist in typical flight control systems and rotor blade hinges, is discussed.

  7. AC losses in horizontally parallel HTS tapes for possible wireless power transfer applications

    NASA Astrophysics Data System (ADS)

    Shen, Boyang; Geng, Jianzhao; Zhang, Xiuchang; Fu, Lin; Li, Chao; Zhang, Heng; Dong, Qihuan; Ma, Jun; Gawith, James; Coombs, T. A.

    2017-12-01

    This paper presents the concept of using horizontally parallel HTS tapes with AC loss study, and the investigation on possible wireless power transfer (WPT) applications. An example of three parallel HTS tapes was proposed, whose AC loss study was carried out both from experiment using electrical method; and simulation using 2D H-formulation on the FEM platform of COMSOL Multiphysics. The electromagnetic induction around the three parallel tapes was monitored using COMSOL simulation. The electromagnetic induction and AC losses generated by a conventional three turn coil was simulated as well, and then compared to the case of three parallel tapes with the same AC transport current. The analysis demonstrates that HTS parallel tapes could be potentially used into wireless power transfer systems, which could have lower total AC losses than conventional HTS coils.

  8. Comparison of removed dentin thickness with hand and rotary instruments

    PubMed Central

    Shahriari, Shahriar; Abedi, Hasan; Hashemi, Mahdi; Jalalzadeh, Seyed Mohsen

    2009-01-01

    INTRODUCTION: The aim of this study was to evaluate the amount of dentine removed after canal preparation using stainless steel (SS) hand instruments or rotary ProFile instruments. MATERIALS AND METHODS: Thirty-six extracted human teeth with root canal curvatures less than 30º were embedded in clear polyester resin. The roots were cut horizontally at apical 2, 4 and 7 mm. Dentin thickness was measured at each section and the sections were accurately reassembled using a muffle. Root canals were randomly prepared by SS hand instruments or rotary ProFile instruments. Root sections were again separated, and the remaining dentin thickness was measured. Mann-Whitney U and t tests were performed for analytic comparison of the results. RESULTS: The thickness of removed dentin was significantly different between the two used methods (P<0.05). Significantly greater amounts of dentin was removed mesially in all sections in hand instrumentation group (P<0.001). CONCLUSION: ProFile rotary instrumentation prepares root canals with a greater conservation of tooth structure. PMID:23940489

  9. The impact of circulation control on rotary aircraft controls systems

    NASA Technical Reports Server (NTRS)

    Kingloff, R. F.; Cooper, D. E.

    1987-01-01

    Application of circulation to rotary wing systems is a new development. Efforts to determine the near and far field flow patterns and to analytically predict those flow patterns have been underway for some years. Rotary wing applications present a new set of challenges in circulation control technology. Rotary wing sections must accommodate substantial Mach number, free stream dynamic pressure and section angle of attack variation at each flight condition within the design envelope. They must also be capable of short term circulation blowing modulation to produce control moments and vibration alleviation in addition to a lift augmentation function. Control system design must provide this primary control moment, vibration alleviation and lift augmentation function. To accomplish this, one must simultaneously control the compressed air source and its distribution. The control law algorithm must therefore address the compressor as the air source, the plenum as the air pressure storage and the pneumatic flow gates or valves that distribute and meter the stored pressure to the rotating blades. Also, mechanical collective blade pitch, rotor shaft angle of attack and engine power control must be maintained.

  10. Rotary acceleration of a subject inhibits choice reaction time to motion in peripheral vision

    NASA Technical Reports Server (NTRS)

    Borkenhagen, J. M.

    1974-01-01

    Twelve pilots were tested in a rotation device with visual simulation, alone and in combination with rotary stimulation, in experiments with variable levels of acceleration and variable viewing angles, in a study of the effect of S's rotary acceleration on the choice reaction time for an accelerating target in peripheral vision. The pilots responded to the direction of the visual motion by moving a hand controller to the right or left. Visual-plus-rotary stimulation required a longer choice reaction time, which was inversely related to the level of acceleration and directly proportional to the viewing angle.

  11. Towards a 1000 tracks digital tape recorder

    NASA Technical Reports Server (NTRS)

    Coutellier, J. M.; Castera, J. P.; Colineau, J.; Lehureau, J. C.; Maurice, F.; Hanna, C.

    1993-01-01

    As the demand for high data rate (up to 1 Gb/s), high density (down to 1 sq micron/bit) tape recorder increases, the main investigation trend is an improvement of the well known helical scan concept. The drawbacks of this technology are also well known; sophisticated mechanics, head to tape contact, and wear problems. In our fixed head approach, the recorder mechanics is made much more simple, but the complexity is turned towards the integrated magnetic components, which have to record and reproduce hundreds of tracks in parallel. Our multiplexed write inductive head and magneto-optical readout head will be described, and the global system performances evaluated.

  12. Benefits of the rotary diaphragm pump.

    PubMed

    Borstell, D

    2005-03-01

    The huge variety of applications in the medical field represents a challenge for the design of miniature pumps. There are well-known designs such as piston pumps, eccenter diaphragm pumps and peristaltic pumps. There are lesser-known types such as the rotary diaphragm pump, the subject of this article. Its design features, variants, and advantages and disadvantages are examined.

  13. Conceptual Study of Rotary-Wing Microrobotics

    DTIC Science & Technology

    2008-03-27

    tensile residual stress, respectively [78-80]. ......... 48  Table 8: Wing-T design parameters compared to Tsuzuki’s recommendations. ....... 73...Table 13: Summary of key parameters for a feasible rotary-wing MEMS robot design...Direct Methanol Fuel Cell DOF Degrees of Freedom DRIE Deep Reactive Ion Etch FEA Finite Element Analysis FEM Finite Element Modeling FOM Figure

  14. Is Kinesio Taping to Generate Skin Convolutions Effective for Increasing Local Blood Circulation?

    PubMed Central

    Yang, Jae-Man; Lee, Jung-Hoon

    2018-01-01

    Background It is unclear whether traditional application of Kinesio taping, which produces wrinkles in the skin, is effective for improving blood circulation. This study investigated local skin temperature changes after the application of an elastic therapeutic tape using convolution and non-convolution taping methods (CTM/NCTM). Material/Methods Twenty-eight pain-free men underwent CTM and NCTM randomly applied to the right and left sides of the lower back. Using infrared thermography, skin temperature was measured before, immediately after application, 5 min later, 15 min later, and after the removal of the tape. Results Both CTM and NCTM showed a slight, but significant, decrease in skin temperature for up to 5 min. The skin temperature at 15 min and after the removal of the tape was not significantly different from the initial temperature for CTM and NCTM. There were also no significant differences in the skin temperatures between CTM and NCTM. Conclusions Our findings do not support a therapeutic effect of wrinkling the skin with elastic tape application as a technique to increase local blood flow. PMID:29332101

  15. Is Kinesio Taping to Generate Skin Convolutions Effective for Increasing Local Blood Circulation?

    PubMed

    Yang, Jae-Man; Lee, Jung-Hoon

    2018-01-14

    BACKGROUND It is unclear whether traditional application of Kinesio taping, which produces wrinkles in the skin, is effective for improving blood circulation. This study investigated local skin temperature changes after the application of an elastic therapeutic tape using convolution and non-convolution taping methods (CTM/NCTM). MATERIAL AND METHODS Twenty-eight pain-free men underwent CTM and NCTM randomly applied to the right and left sides of the lower back. Using infrared thermography, skin temperature was measured before, immediately after application, 5 min later, 15 min later, and after the removal of the tape. RESULTS Both CTM and NCTM showed a slight, but significant, decrease in skin temperature for up to 5 min. The skin temperature at 15 min and after the removal of the tape was not significantly different from the initial temperature for CTM and NCTM. There were also no significant differences in the skin temperatures between CTM and NCTM. CONCLUSIONS Our findings do not support a therapeutic effect of wrinkling the skin with elastic tape application as a technique to increase local blood flow.

  16. Integration of altitude and airspeed information into a primary flight display via moving-tape formats

    NASA Technical Reports Server (NTRS)

    Abbott, Terence S.; Steinmetz, George G.

    1987-01-01

    A ground-based aircraft simulation study was conducted to determine the effect on pilot performance of replacing the electromechanical altimeter and airspeed indicators with electronically generated representations integrated into the primary flight display via moving-tape (linear moving scale) formats. Several key factors relating to moving-tape formats were examined during the study: tape centering, secondary (trend) information, and tape orientation. The factor of centering refers to whether the tape was centered about the actual airspeed or altitude or about some defined reference value. Tape orientation refers to whether the values represented are arranged in either descending or ascending order. Six pilots participated in this study, with each subject performing 18 runs along a single, known flight profile. Subjective results indicated that the moving-tape formats were generally better than that of the conventional instruments. They also indicated that an actual-centered fixed pointer was preferred to a reference-centered pointer. Performance data for a visual secondary task showed that formats not containing trend information produced better performance; however, no difference was noted in airspeed tracking or altitude tracking performance. Regarding tape orientation, subjective comments indicated that there was lower work load and better performance when the airspeed tape had the high numbers at the top.

  17. Scan converting video tape recorder

    NASA Technical Reports Server (NTRS)

    Holt, N. I. (Inventor)

    1971-01-01

    A video tape recorder is disclosed of sufficient bandwidth to record monochrome television signals or standard NTSC field sequential color at current European and American standards. The system includes scan conversion means for instantaneous playback at scanning standards different from those at which the recording is being made.

  18. Rotary and Magnus balances

    NASA Technical Reports Server (NTRS)

    Malcolm, G. N.

    1981-01-01

    Two wind tunnel techniques for determining part of the aerodynamic information required to describe the dynamic bahavior of various types of vehicles in flight are described. Force and moment measurements are determined with a rotary-balance apparatus in a coning motion and with a Magnus balance in a high-speed spinning motion. Coning motion is pertinent to both aircraft and missiles, and spinning is important for spin stabilized missiles. Basic principles of both techniques are described, and specific examples of each type of apparatus are presented. Typical experimental results are also discussed.

  19. Blood loss in the space of Retzius and pelvis with tension-free vaginal tape and trans-obturator tape procedures.

    PubMed

    Huffaker, R Keith; Copas, Pleas

    2006-11-01

    The purpose of this study was to evaluate the space of Retzius and pelvis for hematoma formation and blood loss following placement of tension-free vaginal tapes (TVT) and transobturator tapes (TOT). 25 women were examined with ultrasonography on post-operative days one, two, three, four or five. One patient underwent TVT while the other 24 underwent TOT. Additional procedures were performed on most patients. No hematomas or collections of free fluid were identified post-operatively. TVT and TOT procedures are relatively safe procedures. We encountered no vascular complications in this small series of patients. Review of literature has yielded reports of infrequent complications.

  20. Water-vapor effects on friction of magnetic tape in contact with nickel-zinc ferrite

    NASA Technical Reports Server (NTRS)

    Miyoshi, K.; Buckley, D. H.

    1984-01-01

    The effects of humidity of moist nitrogen on the friction and deformation behavior of magnetic tape in contact with a nickel-zinc ferrite spherical pin were studied. The results indicate that the coefficient of friction is markedly dependent on the ambient relative humidity. Although the coefficient of friction remains low below 40-percent relative humidity, it increases rapidly with increasing relative humidity above 40 percent. The general ambient environment of the tape does not have any effect on the friction behavior if the area where the tape is in sliding contact with the ferrite pin is flooded with controlled nitrogen. The response time for the friction of the tape to humidity changes is about 10 sec. The effect of friction as a function of relative humidity on dehumidifying is very similar to that on humidifying. A surface softening of the tape due to water vapor increases the friction of the tape.

  1. Percussive Augmenter of Rotary Drills for Operating as a Rotary-Hammer Drill

    NASA Technical Reports Server (NTRS)

    Aldrich, Jack Barron (Inventor); Bar-Cohen, Yoseph (Inventor); Sherrit, Stewart (Inventor); Badescu, Mircea (Inventor); Bao, Xiaoqi (Inventor); Scott, James Samson (Inventor)

    2014-01-01

    A percussive augmenter bit includes a connection shaft for mounting the bit onto a rotary drill. In a first modality, an actuator percussively drives the bit, and an electric slip-ring provides power to the actuator while being rotated by the drill. Hammering action from the actuator and rotation from the drill are applied directly to material being drilled. In a second modality, a percussive augmenter includes an actuator that operates as a hammering mechanism that drives a free mass into the bit creating stress pulses that fracture material that is in contact with the bit.

  2. [Deformation evaluation of ProTaper nickel-titanium rotary instruments in curved canals instrumentation in vitro].

    PubMed

    Yan, Hong; Ren, Min; Yin, Xing-Zhe; Zhao, Shu-Yan; Zhang, Cheng-Fei

    2008-04-01

    To evaluate the deformation of ProTaper rotary instruments using in root canals of different curvature in vitro. Extracted first mandibular molars were divided into two experimental groups according to the curvature of mesial buccal canals: group A with moderate curvature and group B with severe curvature. Only the mesial buccal canals of all these teeth were prepared with 6 sets of new ProTaper rotary instruments individually. Additionally, the control group was established with a set of new ProTaper rotary instruments. After finishing each canal preparation, the instruments accompanied by control were examined under the stereomicroscope by an inspector without knowing the group. If distortion, unwinding, abrasion or fracture occurred within one set of instruments, then the whole set was disposed. The sets without problems were in use until 30 times. After 5, 10, 20 times canal preparation, S1, F1 files without deformation under stereomicroscope were examined under scanning electron microscope (SEM). Deformation of ProTaper rotary instruments happened after 12 times in group A and after 7 times in group B. In these two experimental groups, microcracks were found increasing with the times of use under SEM in the instruments without deformation under stereomicroscope. The microcracks on tip of instruments were deep in the early use and became smoother after 10 times. Similar changes happened on knife-edge of instruments, and the microcracks extended over the edge after 20 times use. Root canals with severe curvature tend to damage ProTaper rotary instruments more frequently than moderately curved canals. ProTaper rotary instruments are appropriate to treat less than 7 root canals with severe curvature or 12 root canals with moderate curvature. Stereomicroscope is recommended to detect early damages on Ni-Ti rotary instruments, for preventing instruments fracture in clinic.

  3. Ceramic-metal composites prepared via tape casting and melt infiltration methods

    NASA Astrophysics Data System (ADS)

    Kim, Hyun Jun

    Melt infiltration of preforms prepared by tape casting and lamination has been accomplished using a short-time infiltration process that significantly suppresses reaction product formation. For layered materials produced via infiltration of laminated ceramic tapes, of particular interest is the effect that a large change in microstructure has on infiltration, phase formation, and mechanical properties. Hardness of the fine scale composite layers is approximately three times higher than coarse scale layers, due to greater strength of the fine B4C network. Fractography showed that crack propagation occurred by brittle fracture of the carbide and ductile extension of the metal. Despite large differences in hardness, the fracture mode of the fine and coarse scale microstructures appears identical. Fluid flow modeling for tape casting was conducted with a Newtonian slurry under a parallel blade, and the effect of beveling the blade based on a one dimensional flow model is shown. The discussion on slurry deformation after the blade exit suggests that the mode of slurry deformation depends on the relative importance of the pressure gradient and wall shear and that the existence of zero shear plane might have a negative effect on particle alignment in the tape. The analysis of the flow under a beveled blade predicts that this configuration is more advantageous than the parallel blade for productivity and parallel blade is better for producing uniform particle alignment and thinner tape. Also, the one dimensional flow model for the beveled blade is shown to be a valid approximation of the fluid behavior below a blade angle of 45 degrees. The flow visualization study on tape casting was conducted with a transparent apparatus and model slurry. Most investigators have concluded that the shear stress between the doctor blade and moving carrier causes the particle alignment, but, according to the result of visualization experiment, some degree of particle alignment is already

  4. Sealing performance of a magnetic fluid seal for rotary blood pumps.

    PubMed

    Mitamura, Yoshinori; Takahashi, Sayaka; Kano, Kentaro; Okamoto, Eiji; Murabayashi, Shun; Nishimura, Ikuya; Higuchi, Taka-Aki

    2009-09-01

    A magnetic fluid (MF) for a rotary blood pump seal enables mechanical contact-free rotation of the shaft and, hence, has excellent durability. The performance of a MF seal, however, has been reported to decrease in liquids. We have developed a MF seal that has a "shield" mechanism and a new MF with a higher magnetization of 47.9 kA/m. The sealing performance of the MF seal installed in a rotary blood pump was studied. Under the condition of continuous flow, the MF seal remained in perfect condition against a pressure of 298 mm Hg (pump flow rate: 3.96 L/min). The seal was also perfect against a pressure of 170 mm Hg in a continuous flow of 3.9 L/min for 275 days. We have developed a MF seal that works in liquid against clinically used pressures. The MF seal is promising as a shaft seal for rotary blood pumps.

  5. Degradation of aldrin and endosulfan in rotary drum and windrow composting.

    PubMed

    Ali, Muntjeer; Gani, Khalid M; Kazmi, Absar A; Ahmed, Naseem

    2016-01-01

    Removal efficiencies, kinetics and degradation pathways of aldrin, endosulfan α and endosulfan β in vegetable waste were evaluated during rotary drum and conventional windrow composting. The highest percentage removal of aldrin, endosulfan α and endosulfan β in rotary drum composting was 86.8, 83.3 and 85.3% respectively, whereas in windrow composting, it was 66.6%, 77.7% and 67.2% respectively. The rate constant of degradation of aldrin, endosulfan α and endosulfan β during rotary drum composting ranged from 0.410-0.778, 0.057-0.076 and 0.009-0.061 day(-1) respectively. The pathways of degradation of these pesticides in composting process were proposed. Metabolites dieldrin and 1 hydroxychlorodene formed during composting of aldrin in the vegetable waste indicated the occurrence of epoxidation reaction and oxidation of bridge carbon of aldrin containing the methylene group. Formation of chloroendic acid and chloroendic anhydride during composting of endosulfan containing vegetable waste support the occurrence of endosulfan sulfate and dehydration reaction respectively.

  6. Encapsulated Ball Bearings for Rotary Micro Machines

    DTIC Science & Technology

    2007-01-01

    maintaining fabrication simplicity and stability. Although ball bearings have been demonstrated in devices such as linear micromotors [6, 7] and rotary... micromotors [8], they have yet to be integrated into the microfabrication process to fully constrain the dynamic element. In the cases of both Modafe et

  7. Analysis and test of insulated components for rotary engine

    NASA Technical Reports Server (NTRS)

    Badgley, Patrick R.; Doup, Douglas; Kamo, Roy

    1989-01-01

    The direct-injection stratified-charge (DISC) rotary engine, while attractive for aviation applications due to its light weight, multifuel capability, and potentially low fuel consumption, has until now required a bulky and heavy liquid-cooling system. NASA-Lewis has undertaken the development of a cooling system-obviating, thermodynamically superior adiabatic rotary engine employing state-of-the-art thermal barrier coatings to thermally insulate engine components. The thermal barrier coating material for the cast aluminum, stainless steel, and ductile cast iron components was plasma-sprayed zirconia. DISC engine tests indicate effective thermal barrier-based heat loss reduction, but call for superior coefficient-of-thermal-expansion matching of materials and better tribological properties in the coatings used.

  8. Analysis on design and performance of a solar rotary house

    NASA Astrophysics Data System (ADS)

    Fan, Xuhong; Zhang, Zhaochang; Yang, Fan; Cao, Lilin; Xu, Jing; Yuan, Mingyang

    2017-04-01

    A solar rotary house is designed, composed of rotating main structure, fixed cylinder, rotating drive system, solar photovoltaic system and so on, to achieve 360° rotation. Thus it can change the dark and humid situation of the traditional fixed house shade. Its bearing capacity, driving force and safety are analyzed. Rotary driving force and living energy are provided by solar photovoltaic system on roofs and walls. The Phonenics, Ecotect simulation analysis conclude that the rotating house indoor has better natural ventilation effect, more uniform lighting, better the sunshine time compared with traditional houses, becoming a green, energy-saving, comfortable building model.

  9. Generation and physical characteristics of the LANDSAT-1, -2 and -3 MSS computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1977-01-01

    The generation and format of the LANDSAT 1, 2, and 3 system corrected multispectral scanner computer compatible tapes are discussed. Included in the discussion are the spacecraft sensors, scene characteristics, the transmission of data, and the conversion of the data to computer compatible tapes. Also included in the discussion are geometric and radiometric corrections, tape formats, and the physical characteristics of the tape.

  10. The Goddard helical tape recorder

    NASA Technical Reports Server (NTRS)

    Martin, F. T.; Mccarthy, D. K.

    1972-01-01

    A spacecraft recorder was developed with the objective of functioning continuously for 5 years. The resulting design employed a metallic tape wound in a 200-turn helix. A direct drive, brushless dc torquer and servo speed control drove the recorder at 3 rpm for recording and 54 rpm for playback.

  11. Equivalent dynamic model of DEMES rotary joint

    NASA Astrophysics Data System (ADS)

    Zhao, Jianwen; Wang, Shu; Xing, Zhiguang; McCoul, David; Niu, Junyang; Huang, Bo; Liu, Liwu; Leng, Jinsong

    2016-07-01

    The dielectric elastomer minimum energy structure (DEMES) can realize large angular deformations by a small voltage-induced strain of the dielectric elastomer (DE), so it is a suitable candidate to make a rotary joint for a soft robot. Dynamic analysis is necessary for some applications, but the dynamic response of DEMESs is difficult to model because of the complicated morphology and viscoelasticity of the DE film. In this paper, a method composed of theoretical analysis and experimental measurement is presented to model the dynamic response of a DEMES rotary joint under an alternating voltage. Based on measurements of equivalent driving force and damping of the DEMES, the model can be derived. Some experiments were carried out to validate the equivalent dynamic model. The maximum angle error between model and experiment is greater than ten degrees, but it is acceptable to predict angular velocity of the DEMES, therefore, it can be applied in feedforward-feedback compound control.

  12. Experimental Investigation of a Multi-Cycle Single-Tube Pulse Detonation Rocket Engine with a Coaxial Rotary Valve

    NASA Astrophysics Data System (ADS)

    Matsuoka, Ken; Esumi, Motoki; Ikeguchi, Ken Bryan; Kasahara, Jiro; Matsuo, Akiko; Funaki, Ikkoh

    We developed a novel coaxial rotary valve for a multi-tube PDE. Since this single valve can supply three different gases (fuel, oxidizer and purge gas) into a combustor, the unification of the valve systems for three different gases is possible by using our newly designed valve. A PDRE system can be simple and lightweight by using this valve, and thus its thrust-weight ratio can be increased. We proposed the design of a multi-tube rotary-valved PDRE system by this rotary valve. Moreover, in preparation for a multi-tube rotary-valved PDRE, we carried out the multi-cycle operation experiment by the single-tube rotary-valved PDRE system. The combustion wave velocity was measured to confirm the operation of the PDRE system. Deflagration-to-detonation transition (DDT) was confirmed and DDT distance decreased under the condition of high operation frequency. In addition, a maximum operation frequency was 159 Hz.

  13. In vitro comparison of the cutting efficiency and temperature production of 10 different rotary cutting instruments. Part I: Turbine.

    PubMed

    Ercoli, Carlo; Rotella, Mario; Funkenbusch, Paul D; Russell, Scott; Feng, Changyong

    2009-04-01

    Standards to test the cutting efficiency of dental rotary cutting instruments are either nonexistent or inappropriate, and knowledge of the factors that affect their cutting performance is limited. Therefore, rotary cutting instruments for crown preparation are generally marketed with weak or unsupported claims of superior performance. The purpose of this study was to examine the cutting behavior of a wide selection of rotary cutting instruments under carefully controlled and reproducible conditions with an air-turbine handpiece. Ten groups of rotary cutting instruments (n=30) designed for tooth preparation were selected: 9 diamond rotary cutting instruments (7 multi-use, 2 disposable) and 1 carbide bur. One bur per group was imaged with a scanning electron microscope (SEM) at different magnifications. Macor blocks (n=75) were used as a substrate, and 4 cuts were made on each specimen, using a new rotary cutting instrument each time, for a total of 300 cuts. The cuts were performed with an air-turbine handpiece (Midwest Quiet Air). A computer-controlled, custom-made testing apparatus was used to monitor all sensors and control the cutting action. The data were analyzed to compare the correlation of rotary cutting instrument type, grit, amount of pressure, cutting rate, revolutions per minute (rpm), temperature, and type of handpiece, using 1-way ANOVA and Tukey's Studentized Range test (alpha=.05). Compared to the baseline temperature, all rotary cutting instruments showed a reduction of temperature in the simulated pulp chamber. The Great White Ultra (carbide bur) showed a significantly higher rate of advancement (0.15 mm/s) and lower applied load (106.46 g) and rpm (304,375.97). Tooth preparation with an adequate water flow does not cause harmful temperature changes in the pulp chamber, regardless of rotary cutting instrument type. The tested carbide bur showed greater cutting efficiency than all diamond rotary cutting instruments.

  14. Rotary union for use with ultrasonic thickness measuring probe

    DOEpatents

    Nachbar, H.D.

    1992-09-15

    A rotary union for rotatably supporting an ultrasonic probe operable to nondestructively measure the thickness of steam generator tubes to determine the amount of corrosion experienced by the tubes includes a stationary body having a bore therethrough and an outlet drain, and a fitting rotatably mounted within the upper end of the body. The fitting has a bore aligned with the bore of the body. An electrical cable positioned within a water supply tube in an annular arrangement passes through the bore of the body and the bore of the fitting. This annular arrangement, in turn, is positioned within a connector element which extends outwardly from the fitting bore and is connected to the ultrasonic probe. An elastomeric lower bushing seals the annular arrangement to the lower end of the rotary union body and an elastomeric upper bushing seals the connector element to the fitting to permit the connector element and the ultrasonic probe connected thereto to rotate with the fitting relative to the body. The lower and upper bushings permit water to be passed through the annular arrangement and into the ultrasonic probe and thereafter discharged between the annular arrangement and the connector element to the outlet drain of the rotary union body. 5 figs.

  15. Rotary union for use with ultrasonic thickness measuring probe

    DOEpatents

    Nachbar, Henry D.

    1992-01-01

    A rotary union for rotatably supporting an ultrasonic probe operable to nondestructively measure the thickness of steam generator tubes to determine the amount of corrosion experienced by the tubes includes a stationary body having a bore therethrough and an outlet drain, and a fitting rotatably mounted within the upper end of the body. The fitting has a bore aligned with the bore of the body. An electrical cable positioned within a water supply tube in an annular arrangement passes through the bore of the body and the bore of the fitting. This annular arrangement, in turn, is positioned within a connector element which extends outwardly from the fitting bore and is connected to the ultrasonic probe. An elastomeric lower bushing seals the annular arrangement to the lower end of the rotary union body and an elastomeric upper bushing seals the connector element to the fitting to permit the connector element and the ultrasonic probe connected thereto to rotate with the fitting relative to the body. The lower and upper bushings permit water to be passed through the annular arrangement and into the ultrasonic probe and thereafter discharged between the annular arrangement and the connector element to the outlet drain of the rotary union body.

  16. EFFECT OF ATHLETIC TAPING AND KINESIOTAPING® ON MEASUREMENTS OF FUNCTIONAL PERFORMANCE IN BASKETBALL PLAYERS WITH CHRONIC INVERSION ANKLE SPRAINS

    PubMed Central

    Karatas, Nihan; Baltaci, Gul

    2012-01-01

    Background: Chronic inversion ankle sprains are common in basketball players. The effect of taping on functional performance is disputed in the literature. Kinesiotaping® (KT®) is a new method that is being used as both a therapeutic and performance enhancement tool. To date, it appears that no study has investigated the effect of ankle KT® on functional performance. Purpose: To investigate the effects of different types of taping (KT® using Kinesio Tex®, athletic taping) on functional performance in athletes with chronic inversion sprains of the ankle. Study Design: Crossover Study Design Methods: Fifteen male basketball players with chronic inversion ankle sprains between the ages of 18 and 22 participated in this study. Functional performance tests (Hopping test by Amanda et al, Single Limb Hurdle Test, Standing Heel Rise test, Vertical Jump Test, The Star Excursion Balance Test [SEBT] and Kinesthetic Ability Trainer [KAT] Test) were used to quantify agility, endurance, balance, and coordination. These tests were conducted four times at one week intervals using varied conditions: placebo tape, without tape, standard athletic tape, and KT®. One-way ANOVA tests were used to examine difference in measurements between conditions. Bonferroni correction was applied to correct for repeated testing. Results: There were no significant differences among the results obtained using the four conditions for SEBT (anterior p=0.0699; anteromedial p=0.126; medial p=0.550; posteromedial p=0.587; posterior p=0.754; posterolateral p=0.907; lateral p=0.124; anterolateral p=0.963) and the KAT dynamic measurement (p=0.388). Faster performance times were measured with KT® and athletic tape in single limb hurdle test when compared to placebo and non-taped conditions (Athletic taping- placebo taping: p=0.03; athletic taping- non tape p=0.016;KT®- Placebo taping p=0.042; KT®-Non tape p=0.016). In standing heel rise test and vertical jump test, athletic taping led to decreased

  17. Goddard Space Flight Center specification for Helical-Scan 8-millimeter (mm) magnetic digital data tape cartridge

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1992-01-01

    The same kind of standard and controls are established that are currently in use for the procurement of new analog, digital, and IBM/IBM compatible 3480 tape cartridges, and 1 in wide channel video magnetic tapes. The Magnetic Tape Certification Facility (MTCF) maintains a Qualified Products List (QPL) for the procurement of new magnetic media and uses the following specifications for the QPL and Acceptance Tests: (1) NASA TM-79724 is used for the QPL and Acceptance Testing of new analog magnetic tapes; (2) NASA TM-80599 is used for the QPL and Acceptance Testing of new digital magnetic tapes; (3) NASA TM-100702 is used for the QPL and Acceptance Testing of new IBM/IBM compatible 3840 magnetic tape cartridges; and (4) NASA TM-100712 is used for the QPL and Acceptance Testing of new 1 in wide channel video magnetic tapes. This document will be used for the QPL and Acceptance Testing of new Helical Scan 8 mm digital data tape cartridges.

  18. Strength and reversibility of stereotypes for a rotary control with linear scales.

    PubMed

    Chan, Alan H S; Chan, W H

    2008-02-01

    Using real mechanical controls, this experiment studied strength and reversibility of direction-of-motion stereotypes and response times for a rotary control with horizontal and vertical scales. Thirty-eight engineering undergraduates (34 men and 4 women) ages 23 to 47 years (M=29.8, SD=7.7) took part in the experiment voluntarily. The effects of instruction of change of pointer position and control plane on movement compatibility were analyzed with precise quantitative measures of strength and a reversibility index of stereotype. Comparisons of the strength and reversibility values of these two configurations with those of rotary control-circular display, rotary control-digital counter, four-way lever-circular display, and four-way lever-digital counter were made. The results of this study provided significant implications for the industrial design of control panels for improved human performance.

  19. Machine imparting complex rotary motion for lapping a spherical inner diameter

    DOEpatents

    Carroll, Thomas A.; Yetter, Harold H.

    1986-01-01

    An apparatus for imparting complex rotary motion is used to lap an inner spherical diameter surface of a workpiece. A lapping tool consists of a dome and rod mounted along the dome's vertical axis. The workpiece containing the lapping tool is held in a gimbal which uses power derived from a secondary takeoff means to impart rotary motion about a horizontal axis. The gimbal is rotated about a vertical axis by a take means while mounted at a radially outward position on a rotating arm.

  20. Machine imparting complex rotary motion for lapping a spherical inner diameter

    DOEpatents

    Carroll, T.A.; Yetter, H.H.

    1985-01-30

    An apparatus for imparting complex rotary motion is used to lap an inner spherical diameter surface of a workpiece. A lapping tool consists of a dome and rod mounted along the dome's vertical axis. The workpiece containing the lapping tool is held in a gimbal which uses power derived from a secondary takeoff means to impart rotary motion about a horizontal axis. The gimbal is rotated about a vertical axis by a take means while mounted at a radially outward position on a rotating arm.

  1. Immediate Effects of Kinesiology Taping of Quadriceps on Motor Performance after Muscle Fatigued Induction.

    PubMed

    Ahn, Ick Keun; Kim, You Lim; Bae, Young-Hyeon; Lee, Suk Min

    2015-01-01

    Objectives. The purpose of this cross-sectional single-blind study was to investigate the immediate effects of Kinesiology taping of quadriceps on motor performance after muscle fatigued induction. Design. Randomized controlled cross-sectional design. Subjects. Forty-five subjects participated in this study. Participants were divided into three groups: Kinesiology taping group, placebo taping group, and nontaping group. Methods. Subjects performed short-term exercise for muscle fatigued induction, followed by the application of each intervention. Peak torque test, one-leg single hop test, active joint position sense test, and one-leg static balance test were carried out before and after the intervention. Results. Peak torque and single-leg hopping distance were significantly increased when Kinesiology taping was applied (p < 0.05). But there were no significant effects on active joint position sense and single-leg static balance. Conclusions. We proved that Kinesiology taping is effective in restoring muscle power reduced after muscle fatigued induction. Therefore, we suggest that Kinesiology taping is beneficial for fatigued muscles.

  2. Effects of functional taping compared with sham taping and minimal intervention on pain intensity and static postural control for patients with non-specific chronic low back pain: a randomised clinical trial protocol.

    PubMed

    Jassi, F J; Del Antônio, T; Moraes, R; George, S Z; Chaves, T C

    2017-06-01

    To investigate the immediate and 1-month effects of functional taping to lumbar spine for pain intensity and postural control in patients with chronic non-specific low back pain. Randomised clinical trial. One hundred and twenty participants aged 18 to 50 years. Participants will be allocated at random to receive one of three interventions: functional star-shape taping for 7 days, sham functional taping for 7 days or minimal intervention, one session. The primary outcomes will be pain intensity and postural control. Four measurements of static posturography will be conducted: pre-intervention, immediately after application of the tape, 7 days post-intervention (after removal of the tape) and 1-month follow-up. The secondary outcomes will be low-back-pain-related disability, global perceived effect of treatment and fear avoidance beliefs. Primary and secondary outcomes will be assessed on three occasions: pre-intervention, 7 days post-intervention and at 1-month follow-up. All statistical analyses will be conducted following intention-to-treat principles, and the treatment effects will be calculated using linear mixed models. The results of this study will determine the effects of functional taping on pain intensity and postural control compared with sham taping and minimal intervention. NCT02546466. Copyright © 2016 Chartered Society of Physiotherapy. All rights reserved.

  3. Effects of low-dye taping on plantar pressure pre and post exercise: an exploratory study.

    PubMed

    Nolan, Damien; Kennedy, Norelee

    2009-04-21

    Low-Dye taping is used for excessive pronation at the subtalar joint of the foot. Previous research has focused on the tape's immediate effect on plantar pressure. Its effectiveness following exercise has not been investigated. Peak plantar pressure distribution provides an indirect representation of subtalar joint kinematics. The objectives of the study were 1) To determine the effects of Low-Dye taping on peak plantar pressure immediately post-application. 2) To determine whether any initial effects are maintained following exercise. 12 asymptomatic subjects participated; each being screened for excessive pronation (navicular drop > 10 mm). Plantar pressure data was recorded, using the F-scan, at four intervals during the testing session: un-taped, baseline-taped, post-exercise session 1, and post-exercise session 2. Each exercise session consisted of a 10-minute walk at a normal pace. The foot was divided into 6 regions during data analysis. Repeated-measures analysis of variance (ANOVA) was used to assess regional pressure variations across the four testing conditions. Reduced lateral forefoot peak plantar pressure was the only significant difference immediately post tape application (p = 0.039). This effect was lost after 10 minutes of exercise (p = 0.036). Each exercise session resulted in significantly higher medial forefoot peak pressure compared to un-taped; (p = 0.015) and (p = 0.014) respectively, and baseline-taped; (p = 0.036) and (p = 0.015) respectively. Medial and lateral rearfoot values had also increased after the second session (p = 0.004), following their non-significant reduction at baseline-taped. A trend towards a medial-to-lateral shift in pressure present in the midfoot immediately following tape application was still present after 20 minutes of exercise. Low-Dye tape's initial effect of reduced lateral forefoot peak plantar pressure was lost after a 10-minute walk. However, the tape continued to have an effect on the medial forefoot after

  4. Visualization of latent fingerprints beneath opaque electrical tapes by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Liu, Kangkang; Zhang, Ning; Meng, Li; Li, Zhigang; Xu, Xiaojing

    2018-03-01

    Electrical tape is found as one type of important trace evidence in crime scene. For example, it is very frequently used to insulate wires in explosive devices in many criminal cases. The fingerprints of the suspects were often left on the adhesive side of the tapes, which can provide very useful clues for the investigation and make it possible for individual identification. The most commonly used method to detect and visualize those latent fingerprints is to peel off each layer of the tapes first and then adopt the chemical methods to develop the fingerprints on the tapes. However, the peeling-off and chemical development process would degrade and contaminate the fingerprints and thus adversely affect the accuracy of identification. Optical coherence tomography (OCT) is a novel forensic imaging modality based on lowcoherence interferometry, which has the advantages of non-destruction, micrometer-level high resolution and crosssectional imaging. In this study, a fiber-based spectral-domain OCT (SD-OCT) system with {6μm resolution was employed to obtain the image of fingerprint sandwiched between two opaque electrical tapes without any pre-processing procedure like peeling-off. Three-dimensional (3D) OCT reconstruction was performed and the subsurface image was produced to visualize the latent fingerprints. The results demonstrate that OCT is a promising tool for recovering the latent fingerprints hidden beneath opaque electrical tape non-destructively and rapidly.

  5. TVT ABBREVO: cadaveric study of tape position in foramen obturatum and adductor region.

    PubMed

    Hubka, Petr; Nanka, Ondrej; Masata, Jaromir; Martan, Alois; Svabik, Kamil

    2016-07-01

    The aim of the study was to describe fixation of the TVT ABBREVO and establish whether the tape penetrates through obturator muscles and membrane (obturator complex) into the adductor region and, if so, how far it penetrates. Eight formalin-embalmed female cadavers were used to simulate TVT ABBREVO surgery (totalling 16 insertions). Following tape insertion, dissection was performed and ends of the tape were identified. In cases of penetration, the length of tape penetrating into the adductor region was measured. Of the 16 cases, the tape ended in the obturator membrane in eight, in the internal obturator muscle in one, and penetrated through the obturator membrane into the external obturator muscle in five, where it remained. In two cases, it penetrated through the obturator internus muscle, obturator membrane and obturator externus muscle into the group of thigh adductors; one penetration was by 3 mm and the second by 10 mm. No contact with the obturator nerve or its branches was noted in any case. No TVT contact with the obturator nerve was noted; tape penetrated into the adductor region in two of the 16 cases.

  6. Thermomechanical Analysis of Shape-Memory Composite Tape Spring

    NASA Astrophysics Data System (ADS)

    Yang, H.; Wang, L. Y.

    2013-06-01

    Intelligent materials and structures have been extensively applied for satellite designs in order to minimize the mass and reduce the cost in the launch of the spacecraft. Elastic memory composites (EMCs) have the ability of high-strain packaging and shape-memory effect, but increase the parts and total weight due to the additional heating system. Shape-memory sandwich structures Li and Wang (J. Intell. Mater. Syst. Struct. 22(14), 1605-1612, 2011) can overcome such disadvantage by using the metal skin acting as the heating element. However, the high strain in the micro-buckled metal skin decreases the deployment efficiency. This paper aims to present an insight into the folding and deployment behaviors of shape-memory composite (SMC) tape springs. A thermomechanical process was analyzed, including the packaging deformation at an elevated temperature, shape frozen at the low temperature and shape recovery after reheating. The result shows that SMC tape springs can significantly decrease the strain concentration in the metal skin, as well as exhibiting excellent shape frozen and recovery behaviors. Additionally, possible failure modes of SMC tape springs were also analyzed.

  7. Methods for tape fabrication of continuous filament composite parts and articles of manufacture thereof

    DOEpatents

    Weisberg, Andrew H

    2013-10-01

    A method for forming a composite structure according to one embodiment includes forming a first ply; and forming a second ply above the first ply. Forming each ply comprises: applying a bonding material to a tape, the tape comprising a fiber and a matrix, wherein the bonding material has a curing time of less than about 1 second; and adding the tape to a substrate for forming adjacent tape winds having about a constant distance therebetween. Additional systems, methods and articles of manufacture are also presented.

  8. Short-Term Effects of Kinesio Taping and Cross Taping Application in the Treatment of Latent Upper Trapezius Trigger Points: A Prospective, Single-Blind, Randomized, Sham-Controlled Trial

    PubMed Central

    Słupska, Lucyna; Paprocka-Borowicz, Małgorzata; Taradaj, Jakub; Bidzińska, Gabriela; Marczyński, Daniel; Cynarska, Aleksandra; Rosińczuk, Joanna

    2015-01-01

    Kinesio taping (KT) may be a new treatment in patients with myofascial trigger points (MTrPs). A new method available for taping practitioners is cross taping (CT). The main objective was to determine how CT, KT, and medical adhesive tape (sham group) affect the subjective assessment of resting bioelectrical activity and pain of the upper trapezius muscle (UT) in patients with MTrPs. 105 volunteers were recruited to participate. The primary outcome was resting bioelectrical activity of UT muscle as assessed by surface electromyography (sEMG) in each group and pain intensity on a visual analog scale (VAS). Assessments were collected before and after intervention and after the 24-hours follow-up. No significant differences were observed in bioelectrical activity of UT between pre-, post-, and follow-up results. In three groups patients had significantly lower pain VAS score after the intervention (CT—p < 0.001, KT—p < 0.001, and sham—p < 0.01). The Kruskal-Wallis ANOVA showed no significant differences in almost all measurements between groups. The application of all three types of tapes does not influence the resting bioelectrical activity of UT muscle and may not lead to a reduction in muscle tone in the case of MTrPs. PMID:26491458

  9. Rotary Transformer Seals Power In

    NASA Technical Reports Server (NTRS)

    Studer, P. A.; Paulkovich, J.

    1982-01-01

    Rotary transformer originally developed for spacecraft transfers electrical power from stationary primary winding to rotating secondary without sliding contacts and very little leakage of electromagnetic radiation. Transformer has two stationary primary windings connected in parallel. Secondary, mounted on a shaft that extends out of housing, rotates between two windings of primary. Shaft of secondary is composed of electrically conducting inner and outer parts separated by an insulator. Electrical contact is made from secondary winding, through shaft, to external leads.

  10. VIEW OF CABLES AND TAPES ASSOCIATED WITH ADRIVE CONTROL ROD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF CABLES AND TAPES ASSOCIATED WITH A-DRIVE CONTROL ROD SYSTEM, AT LEVEL +15’, DIRECTLY ABOVE PDP CONTROL ROOM, LOOKING NORTHWEST. THE CABLES FROM THE PDP ROOM GO THROUGH THE CONCRETE WALL, MAKE A RIGHT ANGLE TURN DOWNWARD, AND DESCEND INTO THE PDP CONTROL ROOM AS VERTICAL TAPES - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  11. Root canal centering ability of rotary cutting nickel titanium instruments: A meta-analysis

    PubMed Central

    Gundappa, Mohan; Bansal, Rashmi; Khoriya, Sarvesh; Mohan, Ranjana

    2014-01-01

    Aim: To systematically review articles on canal centering ability of endodontic rotary cutting Nickel-Titanium (Ni-Ti) instruments and subject results to meta-analysis. Materials and Methods: A comprehensive search was initiated on canal centering ability of different rotary cutting Ni-Ti files such as Protaper, Hero Shaper, K3, Mtwo, Race, Wave One by selecting articles published in peer reviewed journals during 1991-2013 using “Pub Med” database. Inclusion and exclusion criteria were established. A data was created by tabulating: Author name, publication year, sample size, number of experimental groups, methods to evaluate canal centering ability, instrument cross section, taper, tip design, rake angle, mean and standard deviation. The data generated was subjected to meta-analysis. Results: Maximum studies were found to be conducted on mesiobuccal canal of mandibular 1st molar with curvature ranging from 15-60°. The difference in canal centering ability of different rotary cutting Ni-Ti instruments was not statistically significant. Conclusion: All endodontic rotary cutting Ni-Ti instruments are capable of producing centered preparations. Protaper depicted the best centering ability. Computed tomography is an effective method of evaluating canal centering ability. PMID:25506134

  12. [Analysis of interappointment flare-ups after root canal preparation with Mtwo NiTi rotary system].

    PubMed

    Han, Jun-li; He, Hong; Zhu, Ya-qin

    2011-08-01

    To study the interappointment flare-ups after root canal preparation with Mtwo NiTi rotary system and explore the influence factors. Ninty-seven pulp cases caused by caries or invisible cracks which consisted of 37 males and 60 females,16 to 62 years old were selected and divided into 2 groups randomly. One group was treated with Mtwo NiTi rotary system while the other was treated with K file, the interappointment flare-ups after root canal preparation was compared between the 2 groups. The data were subjected to Mann-Whitney U test and X(2) test with SPSS13.0 software package. Less flare-ups occurred in the group of root canal preparation with NiTi rotary system, the difference was statistically significant (P=0.027). Root canal preparation with Mtwo NiTi rotary system could decrease the flare-ups after root canal therapy.

  13. Shaping abilities of two different engine-driven rotary nickel titanium systems or stainless steel balanced-force technique in mandibular molars.

    PubMed

    Matwychuk, Michael J; Bowles, Walter R; McClanahan, Scott B; Hodges, Jim S; Pesun, Igor J

    2007-07-01

    The purpose of this study was to compare apical transportation, working-length changes, and instrumentation time by using nickel-titanium (Ni-Ti) rotary file systems (crown-down method) or stainless steel hand files (balanced-force technique) in mesiobuccal canals of extracted mandibular molars. The curvature of each canal was determined and teeth placed into three equivalent groups. Group 1 was instrumented with Sequence (Brasseler USA, Savannah, GA) rotary files, group 2 with Liberator (Miltex Inc, York, PA) rotary files, and group 3 with Flex-R (Union Broach, New York, NY) files. Pre- and postoperative radiographs were superimposed to measure loss of working length and apical transportation as shown by changes in radius of curvature and the long-axis canal angle. Sequence rotary files, Liberator rotary files, and Flex-R hand files had similar effects on apical canal transportation and changes in working length, with no significant differences detected among the 3 groups. Hand instrumentation times were longer than with either Ni-Ti rotary group, whereas the rotary NiTi groups had a higher incidence of fracture.

  14. Performance measurements and operational characteristics of the Storage Tek ACS 4400 tape library with the Cray Y-MP EL

    NASA Technical Reports Server (NTRS)

    Hull, Gary; Ranade, Sanjay

    1993-01-01

    With over 5000 units sold, the Storage Tek Automated Cartridge System (ACS) 4400 tape library is currently the most popular large automated tape library. Based on 3480/90 tape technology, the library is used as the migration device ('nearline' storage) in high-performance mass storage systems. In its maximum configuration, one ACS 4400 tape library houses sixteen 3480/3490 tape drives and is capable of holding approximately 6000 cartridge tapes. The maximum storage capacity of one library using 3480 tapes is 1.2 TB and the advertised aggregate I/O rate is about 24 MB/s. This paper reports on an extensive set of tests designed to accurately assess the performance capabilities and operational characteristics of one STK ACS 4400 tape library holding approximately 5200 cartridge tapes and configured with eight 3480 tape drives. A Cray Y-MP EL2-256 was configured as its host machine. More than 40,000 tape jobs were run in a variety of conditions to gather data in the areas of channel speed characteristics, robotics motion, time taped mounts, and timed tape reads and writes.

  15. Dual Spark Plugs For Stratified-Charge Rotary Engine

    NASA Technical Reports Server (NTRS)

    Abraham, John; Bracco, Frediano V.

    1996-01-01

    Fuel efficiency of stratified-charge, rotary, internal-combustion engine increased by improved design featuring dual spark plugs. Second spark plug ignites fuel on upstream side of main fuel injector; enabling faster burning and more nearly complete utilization of fuel.

  16. A comparative scanning electron microscopic study of the effect of three different rotary instruments on smear layer formation.

    PubMed

    Shahi, Shahriar; Yavari, Hamid R; Rahimi, Saeed; Reyhani, Mohammad F; Kamarroosta, Zahra; Abdolrahimi, Majid

    2009-03-01

    The aim of this study was to evaluate the effect of RaCe, FlexMaster and ProFile rotary instruments on smear layer formation by scanning electron microscopy. Eighty-four caries-free freshly extracted human single-rooted teeth were selected and divided into three groups, each containing 28 teeth. The teeth were instrumented with rotary instruments sequentially: Group A: ProFile Rotary Instruments; Group B: FlexMaster Rotary Instruments; and Group C: RaCe Rotary Instruments. Instrumentation was performed by the crown-down method and according to the manufacturer's instructions. The specimens were then examined with SEM according to Hülsmann's classification. One-way ANOVA and a post hoc Tukey test were used for statistical analysis. The results showed that there were no statistically significant differences among the three groups in the coronal third (P = 0.39), but at the apical and middle thirds there were statistically significant differences between the RaCe group and the other groups (P < 0.05). Smear layer in the RaCe group was less than that in the ProFile and FlexMaster groups, but the difference between the ProFile group and FlexMaster group was not statistically significant (P > 0.05). It was concluded that RaCe Rotary Instruments produce less smear layer than FlexMaster and ProFile Rotary Instruments.

  17. Testing and Development of a Percussive Augmenter for Rotary Drills

    NASA Technical Reports Server (NTRS)

    Donnelly, Christopher; Bar-Cohen, Yoseph; Chang, Zensheu; Badescu, Mircea; Sherrit, Stewart

    2011-01-01

    Hammering drills are effective in fracturing the drilled medium while rotary drills remove cuttings. The combination provides a highly effective penetration mechanism. Piezoelectric actuators were integrated into an adapter to produce ultrasonic percussion; augmenting rotary drilling. The drill is capable of operating at low power, low applied force and, with proper tuning, low noise. These characteristics are of great interest for future NASA missions and the construction/remodeling industry. The developed augmenter connects a commercially available drill and bit and was tested to demonstrate its capability. Input power to the drill was read using a multimeter and the augmenter received a separate input voltage. The drive frequency of the piezoelectric actuator was controlled by a hill climb algorithm that optimizes and records average power usage to operate the drill at resonating frequency. Testing the rotary drill and augmenter across a range of combinations with total power constant at 160 Watts has shown results in concrete and limestone samples that are as good as or better than the commercial drill. The drill rate was increased 1.5 to over 10 times when compared to rotation alone.

  18. Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems.

    PubMed

    Bürklein, Sebastian; Schäfer, Edgar

    2012-06-01

    The purpose of this in vitro study was to assess the amount of apically extruded debris using rotary and reciprocating nickel-titanium instrumentation systems. Eighty human mandibular central incisors were randomly assigned to 4 groups (n = 20 teeth per group). The root canals were instrumented according to the manufacturers' instructions using the 2 reciprocating single-file systems Reciproc (VDW, Munich, Germany) and WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) and the 2 full-sequence rotary Mtwo (VDW, Munich, Germany) and ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) instruments. Bidistilled water was used as irrigant. The apically extruded debris was collected in preweighted glass vials using the Myers and Montgomery method. After drying, the mean weight of debris was assessed with a microbalance and statistically analyzed using analysis of variance and the post hoc Student-Newman-Keuls test. The time required to prepare the canals with the different instruments was also recorded. The reciprocating files produced significantly more debris compared with both rotary systems (P < .05). Although no statistically significant difference was obtained between the 2 rotary instruments (P > .05), the reciprocating single-file system Reciproc produced significantly more debris compared with all other instruments (P < .05). Instrumentation was significantly faster using Reciproc than with all other instrument (P < .05). Under the condition of this study, all systems caused apical debris extrusion. Full-sequence rotary instrumentation was associated with less debris extrusion compared with the use of reciprocating single-file systems. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Experimental analysis of IMEP in a rotary combustion engine

    NASA Technical Reports Server (NTRS)

    Schock, H. J.; Rice, W. J.; Meng, P. R.

    1981-01-01

    A real time indicated mean effective pressure measurement system is described which is used to judge proposed improvements in cycle efficiency of a rotary combustion engine. This is the first self-contained instrument that is capable of making real time measurements of IMEP in a rotary engine. Previous methods used require data recording and later processing using a digital computer. The unique features of this instrumentation include its ability to measure IMEP on a cycle by cycle, real time basis and the elimination of the need to differentiate volume function in real time. Measurements at two engine speeds (2000 and 3000 rpm) and a full range of loads are presented, although the instrument was designed to operate to speeds of 9000 rpm.

  20. Dross treatment in a rotary arc furnace with graphite electrodes

    NASA Astrophysics Data System (ADS)

    Drouet, Michel G.; Handfield, My; Meunier, Jean; Laflamme, Claude B.

    1994-05-01

    Aluminum baths are always covered with a layer of dross resulting from the aluminum surface oxidation. This dross represents 1-10% of the melt and may contain up to 75wt.% aluminum. Since aluminum production is highly energy intensive, dross recycling is very attractive from both energy and economic standpoints. The conventional recycling process using salt rotary furnaces is thermally inefficient and environmentally unacceptable because of the production of salt slags. Hydro-Quebec has developed a new technology using a rotary arc furnace with graphite electrodes. This process provides aluminum recovery rates of 80-90%, using a highly energy efficient, environmentally sound production method.

  1. Study on verifying the angle measurement performance of the rotary-laser system

    NASA Astrophysics Data System (ADS)

    Zhao, Jin; Ren, Yongjie; Lin, Jiarui; Yin, Shibin; Zhu, Jigui

    2018-04-01

    An angle verification method to verify the angle measurement performance of the rotary-laser system was developed. Angle measurement performance has a great impact on measuring accuracy. Although there is some previous research on the verification of angle measuring uncertainty for the rotary-laser system, there are still some limitations. High-precision reference angles are used in the study of the method, and an integrated verification platform is set up to evaluate the performance of the system. This paper also probes the error that has biggest influence on the verification system. Some errors of the verification system are avoided via the experimental method, and some are compensated through the computational formula and curve fitting. Experimental results show that the angle measurement performance meets the requirement for coordinate measurement. The verification platform can evaluate the uncertainty of angle measurement for the rotary-laser system efficiently.

  2. A new methodology for sizing and performance predictions of a rotary wing ejector

    NASA Astrophysics Data System (ADS)

    Moodie, Alex Montfort

    The application of an ejector nozzle integrated with a reaction drive rotor configuration for a vertical takeoff and landing rotorcraft is considered in this research. The ejector nozzle is a device that imparts energy from a high speed airflow source to a lower speed secondary airflow inside a duct. The overall nozzle exhaust mass flow rate is increased through fluid entrainment, while the exhaust gas velocity is simultaneously decreased. The exhaust gas velocity is strongly correlated to the jet noise produced by the nozzle, making the ejector a good candidate for propulsion system noise reduction. Ejector nozzles are mechanically simple in that there are no moving parts. However, coupled fluid dynamic processes are involved, complicating analysis and design. Geometric definitions of the ejector nozzle are determined through a reduced fidelity, multi-disciplinary, representation of the rotary wing ejector. The resulting rotary wing ejector geometric sizing procedure relates standard vehicle and rotor design parameters to the ejector. Additionally, a rotary wing ejector performance procedure is developed to compare this rotor configuration to a conventional rotor. Performance characteristics and aerodynamic effects of the rotor and ejector nozzle are analytically studied. Ejector nozzle performance, in terms of exit velocities, is compared to the primary reaction drive nozzle; giving an indication of the potential for noise reduction. Computational fluid dynamics are paramount in predicting the aerodynamic effects of the ejector nozzle located at the rotor blade tip. Two-dimensional, steady-state, Reynolds-averaged Navier-Stokes (RANS) models are implemented for sectional lift and drag predictions required for the rotor aerodynamic model associated with both the rotary wing ejector sizing and performance procedures. A three-dimensional, unsteady, RANS simulation of the rotary wing ejector is performed to study the aerodynamic interactions between the ejector

  3. User's guide to the UTIL-ODRC tape processing program. [for the Orbital Data Reduction Center

    NASA Technical Reports Server (NTRS)

    Juba, S. M. (Principal Investigator)

    1981-01-01

    The UTIL-ODRC computer compatible tape processing program, its input/output requirements, and its interface with the EXEC 8 operating system are described. It is a multipurpose orbital data reduction center (ODRC) tape processing program enabling the user to create either exact duplicate tapes and/or tapes in SINDA/HISTRY format. Input data elements for PRAMPT/FLOPLT and/or BATCH PLOT programs, a temperature summary, and a printed summary can also be produced.

  4. A smart rotary technique versus conventional pulpectomy for primary teeth: A randomized controlled clinical study.

    PubMed

    Mokhtari, Negar; Shirazi, Alireza-Sarraf; Ebrahimi, Masoumeh

    2017-11-01

    Techniques with adequate accuracy of working length determination along with shorter duration of treatment in pulpectomy procedure seems to be essential in pediatric dentistry. The aim of the present study was to evaluate the accuracy of root canal length measurement with Root ZX II apex locator and rotary system in pulpectomy of primary teeth. In this randomized control clinical trial complete pulpectomy was performed on 80 mandibular primary molars in 80, 4-6-year-old children. The study population was randomly divided into case and control groups. In control group conventional pulpectomy was performed and in the case group working length was determined by electronic apex locator Root ZXII and instrumented with Mtwo rotary files. Statistical evaluation was performed using Mann-Whitney and Chi-Square tests ( P <0.05). There were no significant differences between electronic apex locator Root ZXII and conventional method in accuracy of root canal length determination. However significantly less time was needed for instrumenting with rotary files ( P =0.000). Considering the comparable results in accuracy of root canal length determination and the considerably shorter instrumentation time in Root ZXII apex locator and rotary system, it may be suggested for pulpectomy in primary molar teeth. Key words: Rotary technique, conventional technique, pulpectomy, primary teeth.

  5. High pressure rotary piston coal feeder

    NASA Technical Reports Server (NTRS)

    Gardner, J. F.; Gencsoy, H. T.; Strimbeck, D. C.

    1977-01-01

    This feeder concept uniquely combines the functions of solids feeding, metering, and pressurization into one compact system. Success with the rotary-piston concept would provide a lower-cost alternative to lock-hopper systems. The design of the feeder is presented, with special emphasis on the difficult problem of seal design. Initial tests will be to check seal performance. Subsequent tests will evaluate solids-feeding ability.

  6. Kinesio taping in musculoskeletal pain and disability that lasts for more than 4 weeks: is it time to peel off the tape and throw it out with the sweat? A systematic review with meta-analysis focused on pain and also methods of tape application.

    PubMed

    Lim, Edwin Choon Wyn; Tay, Mathew Guo Xiang

    2015-12-01

    In recent years, Kinesio tape has been used to support injured muscle and joints, and relieve pain. We compared the pain and disability in individuals with chronic musculoskeletal pain who were treated with Kinesio taping with those using minimal or other treatment approaches. Searches of eight major electronic databases were conducted. Data for pain and disability scores were extracted. Meta-analyses (wherever possible) with either a fixed or random effect(s) model, standardised mean differences (SMDs) and tests of heterogeneity were performed. Seventeen clinical-controlled trials were identified and included in the meta-analyses. When compared to minimal intervention, Kinesio taping provided superior pain relief (pooled SMD=-0.36, 95% CI -0.64 to -0.09, p=0.009) but the pooled disability scores were not significantly different (pooled SMD=-0.41, 95% CI -0.83 to 0.01, p=0.05). No significant differences were found when comparing Kinesio taping to other treatment approaches for pain (pooled SMD=-0.44, 95% CI -1.69 to 0.82, p=0.49) and disability (pooled SMD=0.08, 95% CI -0.27 to 0.43, p=0.65). Kinesio taping is superior to minimal intervention for pain relief. Existing evidence does not establish the superiority of Kinesio taping to other treatment approaches to reduce pain and disability for individuals with chronic musculoskeletal pain. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. Laser-plasma interactions from thin tapes for high-energy electron accelerators and seeding compact FELs

    NASA Astrophysics Data System (ADS)

    Shaw, Brian Henry

    This thesis comprises a detailed investigation of the physics of using a plasma mirror (PM) from a tape by reflecting ultrashort pulses from a laser-triggered surface plasma. The tapes used in the characterization of the PM are VHS and computer data storage tape. The tapes are 6.6 m (computer storage tape) and 15 m (VHS) thick. Each tape is 0.5 inches wide, and 10s of meters of tape are spooled using a tape drive; providing thousands of shots on a single reel of tape. The amount of reflected energy of the PM was studied for different input intensities. The fluence was varied by translating the focus of the laser upstream and downstream of the tape, which changed the spot size on the tape surface and hence changed the fluence. This study measured reflectances from both sides of the two tapes, and for input light of both s and p-polarizations. Lastly, an analytic model was developed to understand the reflectance as a function of fluence for each tape material and polarization. Another application that benefits from the advancements of LPA technology is an LPAbased FEL. By sending a high quality electron bunch through an undulator (a periodic structure of positive and negative magnetic poles), the electrons oscillate transversely to the propagation axis and produce radiation. The 1.5 m THUNDER undulator at the BELLA Center has been commissioned using electron beams of 400MeV beams with broad energy spread (35%). To produce a coherent LPA-based FEL, the beam quality would need to improve to sub-percent level energy spread. A seed source could be used to help induce bunching of the electron beam within the undulator. This thesis described the experimental investigation of the physics of using solid-based surface high-harmonic generation (SHHG) from a thin tape as a possible seed source for an FEL. A thin tape placed within centimeters of the undulator's entrance could act as a harmonic generating source, while simultaneously transmitting an electron beam. This removes

  8. 36 CFR 1275.64 - Reproduction of tape recordings of Presidential conversations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Reproduction of tape... § 1275.64 Reproduction of tape recordings of Presidential conversations. (a) To ensure the preservation... locations established by the Archivist in accordance with § 1275.62. (d) The reproduction for members of the...

  9. 36 CFR 1275.64 - Reproduction of tape recordings of Presidential conversations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Reproduction of tape... § 1275.64 Reproduction of tape recordings of Presidential conversations. (a) To ensure the preservation... locations established by the Archivist in accordance with § 1275.62. (d) The reproduction for members of the...

  10. Design study for multi-channel tape recorder system, volume 1

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The means of storing multispectral, high resolution sensor data on an Earth observing satellite are studied. It is concluded that this is best done digitally on a multi-track, longitudinal, magnetic tape recorder. The machine proposed will store 8 X 10 to the 10th power bits of data on 1040 m of 51 mm-wide magnetic tape mounted on two co-planar reels.

  11. High rate of vaginal erosions associated with the mentor ObTape.

    PubMed

    Yamada, Brian S; Govier, Fred E; Stefanovic, Ksenija B; Kobashi, Kathleen C

    2006-08-01

    The transobturator tape method is a newer surgical technique for the treatment of stress urinary incontinence. Limited data exist related to complications with this approach or the types of mesh products used. We report our experience with vaginal erosions associated with the Mentor ObTape and American Medical Systems Monarc transobturator slings. Beginning in December 2003 selected female patients with anatomic urinary incontinence were prospectively followed after placement of the Mentor ObTape. Beginning in January 2004 we also began using the American Medical Systems Monarc in similar patients. Patients were admitted overnight after surgery, discharged on oral antibiotics, and seen in the clinic at 6 weeks postoperatively. A total of 67 patients have undergone placement of the Mentor ObTape and 9 of those patients (13.4%) have had vaginal extrusions of the sling. Eight patients reported a history of persistent vaginal discharge. One patient presented initially to an outside facility with a left thigh abscess tracking to the left inguinal incision site. Each patient was taken back to the operating room for mesh removal. A total of 56 patients have undergone placement of the AMS Monarc and none have had any vaginal erosions. Our high rate of vaginal extrusion using the ObTape has led us to discontinue the use of this product in our institution. Continued followup of all of these patients will be of critical importance.

  12. Design optimization of superconducting coils based on asymmetrical characteristics of REBCO tapes

    NASA Astrophysics Data System (ADS)

    Hong, Zhiyong; Li, Wenrong; Chen, Yanjun; Gömöry, Fedor; Frolek, Lubomír; Zhang, Min; Sheng, Jie

    2018-07-01

    Angle dependence Ic(B,θ) of superconducting tape is a crucial parameter to calculate the influence of magnetic field during the design of superconducting applications,. This paper focuses on the asymmetrical characteristics found in REBCO tapes and further applications based on this phenomenon. This paper starts with angle dependence measurements of different HTS tapes, asymmetrical characteristics are found in some of the testing samples. On basis of this property, optimization of superconducting coils in superconducting motor, transformer and insert magnet is discussed by simulation. Simplified experiments which represent the structure of insert magnet were carried out to prove the validity of numerical studies. Conclusions obtained in this paper show that the asymmetrical property of superconducting tape is quite important in design of superconducting applications, and optimized winding technique based on this property can be used to improve the performance of superconducting devices.

  13. High Fidelity Tape Transfer Printing Based On Chemically Induced Adhesive Strength Modulation

    NASA Astrophysics Data System (ADS)

    Sim, Kyoseung; Chen, Song; Li, Yuhang; Kammoun, Mejdi; Peng, Yun; Xu, Minwei; Gao, Yang; Song, Jizhou; Zhang, Yingchun; Ardebili, Haleh; Yu, Cunjiang

    2015-11-01

    Transfer printing, a two-step process (i.e. picking up and printing) for heterogeneous integration, has been widely exploited for the fabrication of functional electronics system. To ensure a reliable process, strong adhesion for picking up and weak or no adhesion for printing are required. However, it is challenging to meet the requirements of switchable stamp adhesion. Here we introduce a simple, high fidelity process, namely tape transfer printing(TTP), enabled by chemically induced dramatic modulation in tape adhesive strength. We describe the working mechanism of the adhesion modulation that governs this process and demonstrate the method by high fidelity tape transfer printing several types of materials and devices, including Si pellets arrays, photodetector arrays, and electromyography (EMG) sensors, from their preparation substrates to various alien substrates. High fidelity tape transfer printing of components onto curvilinear surfaces is also illustrated.

  14. Delayed latency of peroneal reflex to sudden inversion with ankle taping or bracing.

    PubMed

    Shima, N; Maeda, A; Hirohashi, K

    2005-01-01

    The purpose of the present study was to examine the effects of ankle taping and bracing based on the peroneal reflex in the hypermobile and normal ankle joints with and without history of ankle injury. Thirty-six ankle joints of 18 collegiate American football athletes with and without previous history of injury were studied. The angle of talar tilt (TT) was measured by stress radiograph for classifying normal (TT5 degrees ) ankles. They were tested with taping, bracing, and without any supports as a control. The latency of peroneus longus muscle was measured by a sudden inversion of 25 degrees using surface EMG signals. The results of the present study show no significant three-way Group (hypermobile or normal ankles) by History (previously injured or uninjured ankles) by Condition (control, taping, or bracing) interaction, while Condition main effect was significant (p<0.05). There were significant differences between control (80.8 ms) and taping (83.8 ms, p<0.01), between control and bracing (83.0 ms, p<0.05), but not between taping and bracing (p>0.05). In conclusion, ankle taping and bracing delayed the peroneal reflex latency not only for hypermobile ankles and/or injured ankle joints but also for intact ankle joints.

  15. Multi-Response Parameter Interval Sensitivity and Optimization for the Composite Tape Winding Process.

    PubMed

    Deng, Bo; Shi, Yaoyao; Yu, Tao; Kang, Chao; Zhao, Pan

    2018-01-31

    The composite tape winding process, which utilizes a tape winding machine and prepreg tapes, provides a promising way to improve the quality of composite products. Nevertheless, the process parameters of composite tape winding have crucial effects on the tensile strength and void content, which are closely related to the performances of the winding products. In this article, two different object values of winding products, including mechanical performance (tensile strength) and a physical property (void content), were respectively calculated. Thereafter, the paper presents an integrated methodology by combining multi-parameter relative sensitivity analysis and single-parameter sensitivity analysis to obtain the optimal intervals of the composite tape winding process. First, the global multi-parameter sensitivity analysis method was applied to investigate the sensitivity of each parameter in the tape winding processing. Then, the local single-parameter sensitivity analysis method was employed to calculate the sensitivity of a single parameter within the corresponding range. Finally, the stability and instability ranges of each parameter were distinguished. Meanwhile, the authors optimized the process parameter ranges and provided comprehensive optimized intervals of the winding parameters. The verification test validated that the optimized intervals of the process parameters were reliable and stable for winding products manufacturing.

  16. Multi-Response Parameter Interval Sensitivity and Optimization for the Composite Tape Winding Process

    PubMed Central

    Yu, Tao; Kang, Chao; Zhao, Pan

    2018-01-01

    The composite tape winding process, which utilizes a tape winding machine and prepreg tapes, provides a promising way to improve the quality of composite products. Nevertheless, the process parameters of composite tape winding have crucial effects on the tensile strength and void content, which are closely related to the performances of the winding products. In this article, two different object values of winding products, including mechanical performance (tensile strength) and a physical property (void content), were respectively calculated. Thereafter, the paper presents an integrated methodology by combining multi-parameter relative sensitivity analysis and single-parameter sensitivity analysis to obtain the optimal intervals of the composite tape winding process. First, the global multi-parameter sensitivity analysis method was applied to investigate the sensitivity of each parameter in the tape winding processing. Then, the local single-parameter sensitivity analysis method was employed to calculate the sensitivity of a single parameter within the corresponding range. Finally, the stability and instability ranges of each parameter were distinguished. Meanwhile, the authors optimized the process parameter ranges and provided comprehensive optimized intervals of the winding parameters. The verification test validated that the optimized intervals of the process parameters were reliable and stable for winding products manufacturing. PMID:29385048

  17. Swollen lymph nodes

    MedlinePlus

    ... lymph nodes, including: Seizure medicines such as phenytoin Typhoid immunization Which lymph nodes are swollen depends on ... hard, irregular, or fixed in place. You have fever, night sweats, or unexplained weight loss. Any node ...

  18. Effect of athletic taping and kinesiotaping® on measurements of functional performance in basketball players with chronic inversion ankle sprains.

    PubMed

    Bicici, Seda; Karatas, Nihan; Baltaci, Gul

    2012-04-01

    Chronic inversion ankle sprains are common in basketball players. The effect of taping on functional performance is disputed in the literature. Kinesiotaping® (KT®) is a new method that is being used as both a therapeutic and performance enhancement tool. To date, it appears that no study has investigated the effect of ankle KT® on functional performance. To investigate the effects of different types of taping (KT® using Kinesio Tex®, athletic taping) on functional performance in athletes with chronic inversion sprains of the ankle. Crossover Study Design Fifteen male basketball players with chronic inversion ankle sprains between the ages of 18 and 22 participated in this study. Functional performance tests (Hopping test by Amanda et al, Single Limb Hurdle Test, Standing Heel Rise test, Vertical Jump Test, The Star Excursion Balance Test [SEBT] and Kinesthetic Ability Trainer [KAT] Test) were used to quantify agility, endurance, balance, and coordination. These tests were conducted four times at one week intervals using varied conditions: placebo tape, without tape, standard athletic tape, and KT®. One-way ANOVA tests were used to examine difference in measurements between conditions. Bonferroni correction was applied to correct for repeated testing. There were no significant differences among the results obtained using the four conditions for SEBT (anterior p=0.0699; anteromedial p=0.126; medial p=0.550; posteromedial p=0.587; posterior p=0.754; posterolateral p=0.907; lateral p=0.124; anterolateral p=0.963) and the KAT dynamic measurement (p=0.388). Faster performance times were measured with KT® and athletic tape in single limb hurdle test when compared to placebo and non-taped conditions (Athletic taping- placebo taping: p=0.03; athletic taping- non tape p=0.016;KT®- Placebo taping p=0.042; KT®-Non tape p=0.016). In standing heel rise test and vertical jump test, athletic taping led to decreased performance. (Standing heel rise test: Athletic taping

  19. Niobium-germanium superconducting tapes for high-field magnet applications

    NASA Technical Reports Server (NTRS)

    Braginski, A. I.; Roland, G. W.; Daniel, M. R.; Woolam, J. A.

    1977-01-01

    A process of fabricating superconducting Nb3Ge tapes by chemical vapor deposition (CVD) has been developed and tapes up to 10 meters long fabricated. The typical properties achieved were: critical temperature T sub c = 20 K, upper critical field H sub c2 = 29 tesla at 4.2 K, and J sub c = 3 to 4 x 10 to the 8th power A m(-2) at 4.2 K, 18 tesla. The relative depression of T sub c and H sub c2 compared with the best thin film samples sputtered on sapphire was due to the presence of Nb5Ge3 second-phase particles used as flux pinning centers and to strains induced by thermal mixmatch with Hastelloy B tape substrates. A peculiar field dependence of flux pinning force that was observed in both CVD and sputtered Nb3Ge indicated a premature pin-breaking mechanism or a phase inhomogeneity. Directions of further optimization work were defined.

  20. Shaping ability of nickel-titanium rotary instruments in curved root canals.

    PubMed

    Talati, Ali; Moradi, Saeed; Forghani, Maryam; Monajemzadeh, Ali

    2013-01-01

    Disinfection and subsequent obturation of the root canal space require adequate mechanical enlargement of the canals. The purpose of this in vitro study was to compare the shaping ability of Mtwo, RaCe and Medin rotary instruments during the preparation of curved root canals. Sixty mesiobuccal root canals of mandibular molars with severe curvatures between 25-35(°) and radius of 4-9 mm were randomly divided into three groups of 20 canals each. Using pre- and post-instrumentation radiographs, straightening of the canal and the apical transportation were determined with AutoCAD software. The data were analyzed using Chi square, analysis of variance, and post-hoc tests and the significance level was set at P<0.05. Mtwo instruments maintained the canal curvature significantly better than Race and Medin instruments (P<0.05). There was significant difference between the rotary instruments for iatrogenic transportation of the major foramen (P>0.05). Under the conditions of this in vitro study, Mtwo instruments seemed superior to the two other rotary instruments.