Sample records for tapered stem applied

  1. Quantification of the Contact Area at the Head-Stem Taper Interface of Modular Hip Prostheses.

    PubMed

    Witt, Florian; Gührs, Julian; Morlock, Michael M; Bishop, Nicholas E

    2015-01-01

    Corrosion of modular taper junctions of hip implants may be associated with clinical failure. Taper design parameters, as well as the intraoperatively applied assembly forces, have been proposed to affect corrosion. Fretting corrosion is related to relative interface shear motion and fluid ingress, which may vary with contact force and area. It was hypothesised in this study that assembly forces modify the extent and distribution of the surface contact area at the taper interface between a cobalt chrome head and titanium stem taper with a standard threaded surface profile. Local abrasion of a thin gold coating applied to the stem taper prior to assembly was used to determine the contact area after disassembly. Profilometry was then used to assess permanent deformation of the stem taper surface profile. With increasing assembly force (500 N, 2000 N, 4000 N and 8000 N) the number of stem taper surface profile ridges in contact with the head taper was found to increase (9.2±9.3%, 65.4±10.8%, 92.8±6.0% and 100%) and the overall taper area in contact was also found to increase (0.6±0.7%, 5.5±1.0%, 9.9±1.1% and 16.1±0.9%). Contact was inconsistently distributed over the length of the taper. An increase in plastic radial deformation of the surface ridges (-0.05±0.14 μm, 0.1±0.14 μm, 0.21±0.22 μm and 0.96±0.25 μm) was also observed with increasing assembly force. The limited contact of the taper surface ridges at lower assembly forces may influence corrosion rates, suggesting that the magnitude of the assembly force may affect clinical outcome. The method presented provides a simple and practical assessment of the contact area at the taper interface.

  2. Quantification of the Contact Area at the Head-Stem Taper Interface of Modular Hip Prostheses

    PubMed Central

    Witt, Florian; Gührs, Julian; Morlock, Michael M.; Bishop, Nicholas E.

    2015-01-01

    Corrosion of modular taper junctions of hip implants may be associated with clinical failure. Taper design parameters, as well as the intraoperatively applied assembly forces, have been proposed to affect corrosion. Fretting corrosion is related to relative interface shear motion and fluid ingress, which may vary with contact force and area. It was hypothesised in this study that assembly forces modify the extent and distribution of the surface contact area at the taper interface between a cobalt chrome head and titanium stem taper with a standard threaded surface profile. Local abrasion of a thin gold coating applied to the stem taper prior to assembly was used to determine the contact area after disassembly. Profilometry was then used to assess permanent deformation of the stem taper surface profile. With increasing assembly force (500 N, 2000 N, 4000 N and 8000 N) the number of stem taper surface profile ridges in contact with the head taper was found to increase (9.2±9.3%, 65.4±10.8%, 92.8±6.0% and 100%) and the overall taper area in contact was also found to increase (0.6±0.7%, 5.5±1.0%, 9.9±1.1% and 16.1±0.9%). Contact was inconsistently distributed over the length of the taper. An increase in plastic radial deformation of the surface ridges (-0.05±0.14 μm, 0.1±0.14 μm, 0.21±0.22 μm and 0.96±0.25 μm) was also observed with increasing assembly force. The limited contact of the taper surface ridges at lower assembly forces may influence corrosion rates, suggesting that the magnitude of the assembly force may affect clinical outcome. The method presented provides a simple and practical assessment of the contact area at the taper interface. PMID:26280914

  3. Mechanical aspects of degree of cement bonding and implant wedge effect.

    PubMed

    Yoon, Yong-San; Oxland, Thomas R; Hodgson, Antony J; Duncan, Clive P; Masri, Bassam A; Choi, Donok

    2008-11-01

    The degree of bonding between the femoral stem and cement in total hip replacement remains controversial. Our objective was to determine the wedge effect by debonding and stem taper angle on the structural behavior of axisymmetric stem-cement-bone cylinder models. Stainless steel tapered plugs with a rough (i.e. bonded) or smooth (i.e. debonded) surface finish were used to emulate the femoral stem. Three different stem taper angles (5 degrees , 7.5 degrees , 10 degrees ) were used for the debonded constructs. Non-tapered and tapered (7.5 degrees ) aluminum cylindrical shells were used to emulate the diaphyseal and metaphyseal segments of the femur. The cement-aluminum cylinder interface was designed to have a shear strength that simulated bone-cement interfaces ( approximately 8MPa). The test involved applying axial compression at a rate of 0.02mm/s until failure. Six specimens were tested for each combination of the variables. Finite element analysis was used to enhance the understanding of the wedge effect. The debonded stems sustained about twice as much load as the bonded stem, regardless of taper angle. The metaphyseal model carried 35-50% greater loads than the diaphyseal models and the stem taper produced significant differences. Based on the finite element analysis, failure was most probably by shear at the cement-bone interface. Our results in this simplified model suggest that smooth (i.e. debonded) stems have greater failure loads and will incur less slippage or shear failure at the cement-bone interface than rough (i.e. bonded) stems.

  4. Fitting and Calibrating a Multilevel Mixed-Effects Stem Taper Model for Maritime Pine in NW Spain

    PubMed Central

    Arias-Rodil, Manuel; Castedo-Dorado, Fernando; Cámara-Obregón, Asunción; Diéguez-Aranda, Ulises

    2015-01-01

    Stem taper data are usually hierarchical (several measurements per tree, and several trees per plot), making application of a multilevel mixed-effects modelling approach essential. However, correlation between trees in the same plot/stand has often been ignored in previous studies. Fitting and calibration of a variable-exponent stem taper function were conducted using data from 420 trees felled in even-aged maritime pine (Pinus pinaster Ait.) stands in NW Spain. In the fitting step, the tree level explained much more variability than the plot level, and therefore calibration at plot level was omitted. Several stem heights were evaluated for measurement of the additional diameter needed for calibration at tree level. Calibration with an additional diameter measured at between 40 and 60% of total tree height showed the greatest improvement in volume and diameter predictions. If additional diameter measurement is not available, the fixed-effects model fitted by the ordinary least squares technique should be used. Finally, we also evaluated how the expansion of parameters with random effects affects the stem taper prediction, as we consider this a key question when applying the mixed-effects modelling approach to taper equations. The results showed that correlation between random effects should be taken into account when assessing the influence of random effects in stem taper prediction. PMID:26630156

  5. Principles of managing Vancouver type B periprosthetic fractures around cemented polished tapered femoral stems.

    PubMed

    Quah, Conal; Porteous, Matthew; Stephen, Arthur

    2017-05-01

    The management of periprosthetic fractures around total hip replacements is a complex and challenging problem. Getting it right first time is an important factor in reducing the morbidity, mortality and financial burden associated with these injuries. Understanding and applying the basic principles of fracture management helps increase the chance of successful treatment. Based on these principles, we suggest a treatment algorithm for managing periprosthetic fractures around polished tapered femoral stems.

  6. Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions?

    PubMed

    Pourzal, Robin; Hall, Deborah J; Ha, Nguyen Q; Urban, Robert M; Levine, Brett R; Jacobs, Joshua J; Lundberg, Hannah J

    2016-10-01

    There are increasing reports of total hip arthroplasty failure subsequent to modular taper junction corrosion. The surfaces of tapers are machined to have circumferential machining marks, resulting in a surface topography of alternating peaks and valleys on the scale of micrometers. It is unclear if the geometry of this machined surface topography influences the degree of fretting and corrosion damage present on modular taper junctions or if there are differences between modular taper junction material couples. (1) What are the differences in damage score and surface topography between CoCr/CoCr and CoCr/Ti modular junctions? (2) How are initial surface topography, flexural rigidity, taper angle mismatch, and time in situ related to visual taper damage scores for CoCr/CoCr couples? (3) How are initial surface topography, flexural rigidity, taper angle mismatch, and time in situ related to visual taper damage scores for CoCr/Ti couples? Damage on stem and head tapers was evaluated with a modified Goldberg score. Differences in damage scores were determined between a group of 140 CoCr/CoCr couples and 129 CoCr/Ti couples using a chi-square test. For a subgroup of 70 retrievals, selected at random, we measured five variables, including initial stem taper machining mark height and spacing, initial head taper roughness, flexural rigidity, and taper angle mismatch. All retrievals were obtained at revision surgeries. None were retrieved as a result of metal-on-metal failures or were recalled implants. Components were chosen so there was a comparable number of each material couple and damage score. Machining marks around the circumference of the tapers were measured using white light interferometry to characterize the initial stem taper surface topography in terms of the height of and spacing between machining mark peaks as well as initial head taper roughness. The taper angle mismatch was assessed with a coordinate measuring machine. Flexural rigidity was determined based on measurements of gross taper dimensions and material properties. Differences of median or mean values of all variables between material couples were determined (Wilcoxon rank-sum tests and t-tests). The effect of all five variables along with time in situ on stem and head taper damage scores was tested with a multiple regression model. With 70 retrievals, a statistical power of 0.8 could be achieved for the model. Damage scores were different between CoCr/CoCr and CoCr/Ti modular taper junction material couples. CoCr/CoCr stem tapers were less likely to be mildly damaged (11%, p = 0.006) but more likely to be severely damaged (4%, p = 0.02) than CoCr/Ti stem tapers (28% and 1%, respectively). CoCr/CoCr couples were less likely to have moderately worn head tapers (7% versus 17%, p = 0.003). Stem taper machining mark height and spacing and head taper roughness were 11 (SD 3), 185 (SD 46), and 0.57 (SD 0.5) for CoCr/CoCr couples and 10 (SD 3), 170 (SD 56), and 0.64 (SD 0.4) for CoCr/Ti couples, respectively. There was no difference (p = 0.09, p = 0.1, p = 0.16, respectively) for either factor between material couples. Larger stem taper machining mark heights (p = 0.001) were associated with lower stem taper damage scores, and time in situ (p = 0.006) was associated with higher stem taper damage scores for CoCr/CoCr material couples. Stem taper machining marks that had higher peaks resulted in slower damage progression over time. For CoCr/Ti material couples, head taper roughness was associated with higher stem (p = 0.001) and head taper (p = 0.003) damage scores, and stem taper machining mark height, but not time in situ, was associated with lower stem taper damage scores (p = 0.007). Stem taper surface topography was related to damage scores on retrieved head-neck modular junctions; however, it affected CoCr/CoCr and CoCr/Ti couples differently. A taper topography of circumferential machining marks with higher peaks appears to enable slower damage progression and, subsequently, a reduction of the reported release of corrosion products. This may be of interest to implant designers and manufacturers in an effort to reduce the effects of metal release from modular femoral components.

  7. Cementless Tapered Wedge Femoral Stems Decrease Subsidence in Obese Patients Compared to Traditional Fit-and-Fill Stems.

    PubMed

    Grant, Tanner W; Lovro, Luke R; Licini, David J; Warth, Lucian C; Ziemba-Davis, Mary; Meneghini, Robert M

    2017-03-01

    Femoral component stability and resistance to subsidence is critical for osseointegration and clinical success in cementless total hip arthroplasty. The purpose of this study was to radiographically evaluate the anatomic fit and subsidence of 2 different proximally tapered, porous-coated modern cementless femoral component designs. A retrospective cohort study of 126 consecutive cementless total hip arthroplasties was performed. Traditional fit-and-fill stems were implanted in the first 61 hips with the remaining 65 receiving morphometric tapered wedge stems. Preoperative bone morphology was radiographically assessed by the canal flare index. Canal fill in the coronal plane, subsidence, and the sagittal alignment of stems was measured digitally on immediate and 1-month postoperative radiographs. Demographics and canal flare indices were similar between groups. The percentage of femoral canal fill was greater in the tapered wedge compared to the fit-and-fill stem (P = .001). There was significantly less subsidence in the tapered wedge design (0.3 mm) compared to the fit-and-fill design (1.1 mm) (P = .001). Subsidence significantly increased as body mass index (BMI) increased in the fit-and-fill stems, a finding not observed in the tapered wedge design (P = .013). An anatomically designed morphometric tapered wedge femoral stem demonstrated greater axial stability and decreased subsidence with increasing BMI than a traditional fit-and-fill stem. The resistance to subsidence, irrespective of BMI, is likely due to the inherent axial stability of a tapered wedge design and may be the optimal stem design for obese patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Ceramic Heads Decrease Metal Release Caused by Head-taper Fretting and Corrosion.

    PubMed

    Kocagoz, Sevi B; Underwood, Richard J; MacDonald, Daniel W; Gilbert, Jeremy L; Kurtz, Steven M

    2016-04-01

    Metal release resulting from taper fretting and corrosion is a clinical concern, because wear and corrosion products may stimulate adverse local tissue reactions. Unimodular hip arthroplasties have a conical taper between the femoral head (head bore taper) and the femoral stem (stem cone taper). The use of ceramic heads has been suggested as a way of reducing the generation of wear and corrosion products from the head bore/stem cone taper junction. A previous semiquantitative study found that ceramic heads had less visual evidence of fretting-corrosion damage compared with CoCr heads; but, to our knowledge, no studies have quantified the volumetric material loss from the head bore and stem cone tapers of a matched cohort of ceramic and metal heads. We asked: (1) Do ceramic heads result in less volume of material loss at the head-stem junction compared with CoCr heads; (2) do stem cone tapers have less volumetric material loss compared with CoCr head bore tapers; (3) do visual fretting-corrosion scores correlate with volumetric material loss; and (4) are device, patient, or intraoperative factors associated with volumetric material loss? A quantitative method was developed to estimate volumetric material loss from the head and stem taper in previously matched cohorts of 50 ceramic and 50 CoCr head-stem pairs retrieved during revision surgery for causes not related to adverse reactions to metal particles. The cohorts were matched according to (1) implantation time, (2) stem flexural rigidity, and (3) lateral offset. Fretting corrosion was assessed visually using a previously published four-point, semiquantitative scoring system. The volumetric loss was measured using a precision roundness machine. Using 24 equally spaced axial traces, the volumetric loss was estimated using a linear least squares fit to interpolate the as-manufactured surfaces. The results of this analysis were considered in the context of device (taper angle clearance, head size, head offset, lateral offset, stem material, and stem surface finish) and patient factors that were obtained from the patients' operative records (implantation time, age at insertion, activity level, and BMI). The cumulative volumetric material losses estimated for the ceramic cohort had a median of 0.0 mm(3) per year (range, 0.0-0.4 mm(3)). The cumulative volumetric material losses estimated for the CoCr cohort had a median of 0.1 mm(3) per year (range, 0.0-8.8 mm(3)). An order of magnitude reduction in volumetric material loss was found when a ceramic head was used instead of a CoCr head (p < 0.0001). In the CoCr cohort, the femoral head bore tapers had a median material loss of 0.02 mm(3) (range, 0.0-8.7 mm(3)) and the stem cone tapers had a median material loss of 0.0 mm(3) (range, 0.0-0.32 mm(3)/year). There was greater material loss from femoral head bore tapers compared with stem cone tapers in the CoCr cohort (p < 0.001). There was a positive correlation between visual scoring and volumetric material loss (Spearman's ρ = 0.67, p < 0.01). Although visual scoring was effective for preliminary screening to separate tapers with no or mild damage from tapers with moderate to severe damage, it was not capable of discriminating in the large range of material loss observed at the taper surfaces with moderate to severe fretting-corrosion damage, indicated with a score of 3 or 4. We observed no correlations between volumetric material loss and device and patient factors. The majority of estimated material loss from the head bore-stem cone junctions resulting from taper fretting and corrosion was from the CoCr head bore tapers as opposed to the stem cone tapers. Additionally, the total material loss from the ceramic cohort showed a reduction in the amount of metal released by an order of magnitude compared with the CoCr cohort. We found that ceramic femoral heads may be an effective means by which to reduce metal release caused by taper fretting and corrosion at the head bore-stem cone modular interface in THAs.

  9. Stubby stems: good things come in small packages.

    PubMed

    Lombardi, Adolph V; Berend, Keith R; Ng, Vincent Y

    2011-09-09

    Standard-length porous-coated tapered femoral stems perform exceedingly well in primary total hip arthroplasty (THA) at long-term follow-up. Nevertheless, there are multiple reasons to strongly consider the relatively new concept of short tapered stems. First, there is already a wide variation in the lengths of "standard" components and the ideal length is unknown. The goal of tapered stems is to load the proximal femur, and shortened stems accomplish this task. Second, while the distal extension may help prevent varus, unlike cemented stems, which are failure-prone with varus alignment, tapered designs are not. Additionally, elimination of the distal extension may reduce potential stress shielding. Third, short stems obviate problems with proximal-distal mismatch, excessive femoral bowing, diaphyseal deformities, and preexisting hardware. Fourth, implantation of smaller components requires less violation of bone and soft tissue, facilitating less invasive surgical approaches and favorable revision settings if necessary. Fifth, in comparison to hip resurfacing and other unconventional short-stem designs, tapered stems are familiar to most orthopedic surgeons and do not incur a steep learning curve. Finally, our early experience with this implant in 1750 THAs since 2006 has been excellent. In a series of >650 THA, compared to standard-length tapered stems, the short stem had equivalent clinical outcome scores, significantly fewer femoral fractures (12/389 [3.1%] vs 1/269 [0.4%]), and only 1 (1/269 [0.4%]) femoral revision (infection) at 2-year follow-up. Short stems represent the logical progression of a proven precedent in standard-length tapered stems. Copyright 2011, SLACK Incorporated.

  10. Evaluation of the Painful Dual Taper Modular Neck Stem Total Hip Arthroplasty: Do They All Require Revision?

    PubMed

    Kwon, Young-Min

    2016-07-01

    Although dual taper modular-neck total hip arthroplasty (THA) design with additional neck-stem modularity has the potential to optimize hip biomechanical parameters by facilitating adjustments of leg length, femoral neck version and offset, there is increasing concern regarding this stem design as a result of the growing numbers of adverse local tissue reactions due to fretting and corrosion at the neck-stem taper junction. Implant factors such as taper cone angle, taper surface roughness, taper contact area, modular neck taper metallurgy, and femoral head size play important roles in influencing extent of taper corrosion. There should be a low threshold to conduct a systematic clinical evaluation of patients with dual-taper modular-neck stem THA using systematic risk stratification algorithms as early recognition and diagnosis will ensure prompt and appropriate treatment. Although specialized tests such as metal ion analysis and cross-sectional imaging modalities such as metal artifact reduction sequence magnetic resonance imaging (MARS MRI) are useful in optimizing clinical decision-making, overreliance on any single investigative tool in the clinical decision-making process for revision surgery should be avoided. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Do Stem Taper Microgrooves Influence Taper Corrosion in Total Hip Arthroplasty? A Matched Cohort Retrieval Study.

    PubMed

    Arnholt, Christina M; MacDonald, Daniel W; Underwood, Richard J; Guyer, Eric P; Rimnac, Clare M; Kurtz, Steven M; Mont, Michael A; Klein, Gregg R; Lee, Gwo-Chin; Chen, Antonia F; Hamlin, Brian R; Cates, Harold E; Malkani, Arthur L; Kraay, Matthew J

    2017-04-01

    Previous studies identified imprinting of the stem morphology onto the interior head bore, leading researchers to hypothesize an influence of taper topography on mechanically assisted crevice corrosion. The purpose of this study was to analyze whether microgrooved stem tapers result in greater fretting corrosion damage than smooth stem tapers. A matched cohort of 120 retrieved head-stem pairs from metal-on-polyethylene bearings was created controlling for implantation time, flexural rigidity, apparent length of engagement, and head size. There were 2 groups of 60 heads each, mated with either smooth or microgrooved stem tapers. A high-precision roundness machine was used to measure and categorize the surface morphology. Fretting corrosion damage at the head-neck junction was characterized using the Higgs-Goldberg scoring method. Fourteen of the most damaged heads were analyzed for the maximum depth of material loss and focused ion beam cross-sectioned to view oxide and base metal. Fretting corrosion damage was not different between the 2 cohorts at the femoral head (P = .14, Mann-Whitney) or stem tapers (P = .35). There was no difference in the maximum depths of material loss between the cohorts (P = .71). Cross-sectioning revealed contact damage, signs of micro-motion, and chromium-rich oxide layers in both cohorts. Microgroove imprinting did not appear to have a different effect on the fretting corrosion behavior. The results of this matched cohort retrieval study do not support the hypothesis that taper surfaces with microgrooved stems exhibit increased in vivo fretting corrosion damage or material release. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. The Influence of Contamination and Cleaning on the Strength of Modular Head Taper Fixation in Total Hip Arthroplasty.

    PubMed

    Krull, Annika; Morlock, Michael M; Bishop, Nicholas E

    2017-10-01

    Intraoperative interface contamination of modular head-stem taper junctions of hip implants can lead to poor fixation strength, causing fretting and crevice corrosion or even stem taper fracture. Careful cleaning before assembly should help to reduce these problems. The purpose of this study was to determine the effect of cleaning (with and without drying) contaminated taper interfaces on the taper fixation strength. Metal or ceramic heads were impacted onto titanium alloy stem tapers with cleaned or contaminated (fat or saline solution) interfaces. The same procedure was performed after cleaning and drying the contaminated interfaces. Pull-off force was used to determine the influence of contamination and cleaning on the taper strength. Pull-off forces after contamination with fat were significantly lower than those for uncontaminated interfaces for both head materials. Pull-off forces after application of saline solution were not significantly different from those for uncontaminated tapers. However, a large variation in taper strength was observed, pull-off forces for cleaned and dried tapers were similar to those for uncontaminated tapers for both head materials. Intraoperative contamination of taper interfaces may be difficult to detect but has a major influence on taper fixation strength. Cleaning of the stem taper with saline solution and drying with gauze directly before assembly allows the taper strength of the pristine components to be achieved. Not drying the taper results in a large variation in pull-off forces, emphasizing that drying is essential for sufficient and reproducible fixation strength. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Do Stem Taper Microgrooves Influence Taper Corrosion in Total Hip Arthroplasty? A Matched Cohort Retrieval Study

    PubMed Central

    Arnholt, Christina M.; MacDonald, Daniel W.; Underwood, Richard; Guyer, Eric P.; Rimnac, Clare M.; Kurtz, Steven M.; Mont, Michael A.; Klein, Gregg; Lee, Gwo-Chin; Chen, Antonia F.; Hamlin, Brian; Cates, Harold; Malkani, Arthur; Kraay, Matthew

    2017-01-01

    Background Previous studies identified imprinting of the stem morphology onto the interior head bore, leading researchers to hypothesize an influence of taper topography on mechanically assisted crevice corrosion (MACC). The purpose of this study was to analyze whether micro-grooved stem tapers result in greater fretting corrosion damage than smooth stem tapers. Methods A matched cohort of 120 retrieved head-stem pairs from metal-on-polyethylene bearings was created controlling for implantation time, flexural rigidity, apparent length of engagement, and head size. There were two groups of 60 heads each, mated with either smooth or micro-grooved stem tapers. A high precision roundness machine was used to measure and categorize the surface morphology. Fretting corrosion damage at the head/neck junction was characterized using the Higgs-Goldberg scoring method. Fourteen of the most damaged heads, were analyzed for the maximum depth of material loss and focused ion beam (FIB) cross-sectioned to view oxide and base metal. Results Fretting corrosion damage was not different between the two cohorts at the femoral head (p = 0.14, Mann Whitney) or stem tapers (p = 0.35). There was no difference in the maximum depths of material loss between the cohorts (p = 0.71). Cross sectioning revealed contact damage, signs of micro-motion, and chromium rich oxide layers in both cohorts. Micro-groove imprinting did not appear to have a different effect on the fretting corrosion behavior. Conclusion The results of this matched cohort retrieval study do not support the hypothesis that taper surfaces with micro-grooved stems exhibit increased in vivo fretting corrosion damage or material release. PMID:28111124

  14. Stem geometry changes initial femoral fixation stability of a revised press-fit hip prosthesis: A finite element study.

    PubMed

    Russell, Robert D; Huo, Michael H; Rodrigues, Danieli C; Kosmopoulos, Victor

    2016-11-14

    Stable femoral fixation during uncemented total hip arthroplasty is critical to allow for subsequent osseointegration of the prosthesis. Varying stem designs provide surgeons with multiple options to gain femoral fixation. The purpose of this study was to compare the initial fixation stability of cylindrical and tapered stem implants using two different underreaming techniques (press-fit conditions) for revision total hip arthroplasty (THA). A finite element femur model was created from three-dimensional computed tomography images simulating a trabecular bone defect commonly observed in revision THA. Two 18-mm generic femoral hip implants were modeled using the same geometry, differing only in that one had a cylindrical stem and the other had a 2 degree tapered stem. Surgery was simulated using a 0.05-mm and 0.01-mm press-fit and tested with a physiologically relevant loading protocol. Mean contact pressure was influenced more by the surgical technique than by the stem geometry. The 0.05-mm press-fit condition resulted in the highest contact pressures for both the cylindrical (27.35 MPa) and tapered (20.99 MPa) stems. Changing the press-fit to 0.01-mm greatly decreased the contact pressure by 79.8% and 78.5% for the cylindrical (5.53 MPa) and tapered (4.52 MPa) models, respectively. The cylindrical stem geometry consistently showed less relative micromotion at all the cross-sections sampled as compared to the tapered stem regardless of press-fit condition. This finite element analysis study demonstrates that tapered stem results in lower average contact pressure and greater micromotion at the implant-bone interface than a cylindrical stem geometry. More studies are needed to establish how these different stem geometries perform in such non-ideal conditions encountered in revision THA cases where less bone stock is available.

  15. Bending stiffness, torsional stability, and insertion force of cementless femoral stems.

    PubMed

    Incavo, S J; Johnson, C C; Churchill, D L; Beynnon, B D

    2001-04-01

    In cementless total hip arthroplasty, increased femoral stem flexibility and decreased fracture propensity are desirable characteristics. The slotting and tapering of the stem have been introduced to achieve this. These features should not, however, be allowed to interfere with the ability of the distal stem to provide initial mechanical stability, especially under rotation. This study was done to investigate the ability of slotted and tapered stem designs to reduce stiffness and insertion force while still maintaining adequate torsional strength. The torsional strength, maximum insertion force, and insertional work of straight, slotted, and taper stems were measured by inserting each type into rigid polyurethane foam and torque testing to failure. Bending stiffness of each stem design was calculated using numerical methods. When compared to a straight stem, a unislot stem has similar torsional strength, maximum insertional force, and work of insertion. The bending stiffness is decreased by 19% to 82% depending on the bending direction. A trislot design decreased torque strength by 29%, maximal insertion force by 36%, and work by 11%. Bending stiffness was decreased by 74% and was not dependent on bending direction. A 0.5-mm taper decreased torque strength by 11% and insertional work by 14%. No difference was seen in maximum insertional force. We conclude that the design features studied (slots and taper) are effective in decreasing stem stiffness and reducing fracture propensity.

  16. Total Hip Intraoperative Femur Fracture: Do the Design Enhancements of a Second-Generation Tapered-Wedge Stem Reduce the Incidence?

    PubMed

    Colacchio, Nicholas D; Robbins, Claire E; Aghazadeh, Mehran S; Talmo, Carl T; Bono, James V

    2017-10-01

    Intraoperative femur fracture (IFF) is a well-known complication in primary uncemented total hip arthroplasty (THA). Variations in implant instrumentation design and operative technique may influence the risk of IFF. This study investigates IFF between a standard uncemented tapered-wedge femoral stem and its second-generation successor with the following design changes: size-specific medial curvature, proportional incremental stem growth, modest reduction in stem length, and distal lateral relief. A single experienced surgeon's patient database was retrospectively queried for IFF occurring during primary uncemented THA using a standard tapered-wedge femoral stem system or a second-generation stem. All procedures were performed using soft tissue preserving anatomic capsule repair and posterior approach. The primary outcome measure was IFF. A z-test of proportions was performed to determine significant difference between the 2 stems with respect to IFF. Patient demographics, Dorr classification, and implant characteristics were also examined. Forty-one of 1510 patients (2.72%) who received a standard tapered-wedge femoral stem sustained an IFF, whereas 5 of 800 patients (0.63%) using the second-generation stem incurred an IFF. No other significant associations were found. A standard tapered-wedge femoral stem instrumentation system resulted in greater than 4 times higher incidence of IFF than its second-generation successor used for primary uncemented THA. Identifying risk factors for IFF is necessary to facilitate implant system improvements and thus maximize patient outcomes. Copyright © 2017. Published by Elsevier Inc.

  17. Development and verification of a cementless novel tapered wedge stem for total hip arthroplasty.

    PubMed

    Faizan, Ahmad; Wuestemann, Thies; Nevelos, Jim; Bastian, Adam C; Collopy, Dermot

    2015-02-01

    Most current tapered wedge hip stems were designed based upon the original Mueller straight stem design introduced in 1977. These stems were designed to have a single medial curvature and grew laterally to accommodate different sizes. In this preclinical study, the design and verification of a tapered wedge stem using computed tomography scans of 556 patients are presented. The computer simulation demonstrated that the novel stem, designed for proximal engagement, allowed for reduced distal fixation, particularly in the 40-60 year male population. Moreover, the physical micromotion testing and finite element analysis demonstrated that the novel stem allowed for reduced micromotion. In summary, preclinical data suggest that the computed tomography based stem design described here may offer enhanced implant fit and reduced micromotion. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Simple taper: Taper equations for the field forester

    Treesearch

    David R. Larsen

    2017-01-01

    "Simple taper" is set of linear equations that are based on stem taper rates; the intent is to provide taper equation functionality to field foresters. The equation parameters are two taper rates based on differences in diameter outside bark at two points on a tree. The simple taper equations are statistically equivalent to more complex equations. The linear...

  19. A short tapered stem reduces intraoperative complications in primary total hip arthroplasty.

    PubMed

    Molli, Ryan G; Lombardi, Adolph V; Berend, Keith R; Adams, Joanne B; Sneller, Michael A

    2012-02-01

    While short-stem design is not a new concept, interest has surged with increasing utilization of less invasive techniques. Short stems are easier to insert through small incisions. Reliable long-term results including functional improvement, pain relief, and implant survival have been reported with standard tapered stems, but will a short taper perform as well? We compared short, flat-wedge, tapered, broach-only femoral stems to standard-length, double-tapered, ream and broach femoral stems in terms of intraoperative complications, short-term survivorship, and pain and function scores. We retrospectively reviewed the records of 606 patients who had 658 THAs using a less invasive direct lateral approach from January 2006 to March 2008. Three hundred sixty patients (389 hips) had standard-length stems and 246 (269 hips) had short stems. Age averaged 63 years, and body mass index averaged 30.7 kg/m(2). We recorded complications and pain and function scores and computed short-term survival. Minimum followup was 0.8 months (mean, 29.2 months; range, 0.8-62.2 months). We observed a higher rate of intraoperative complications with the standard-length stems (3.1%; three trochanteric avulsions, nine femoral fractures) compared with the shorter stems (0.4%; one femoral fracture) and managed all complications with application of one or more cerclage cables. There were no differences in implant survival, Harris hip score, and Lower Extremity Activity Scale score between groups. Fewer intraoperative complications occurred with the short stems, attesting to the easier insertion of these devices. While longer followup is required, our early results suggest shortened stems can be used with low complication rates and do not compromise the survival and functional outcome of cementless THA. Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  20. Artificial Intelligence Procedures for Tree Taper Estimation within a Complex Vegetation Mosaic in Brazil

    PubMed Central

    Nunes, Matheus Henrique

    2016-01-01

    Tree stem form in native tropical forests is very irregular, posing a challenge to establishing taper equations that can accurately predict the diameter at any height along the stem and subsequently merchantable volume. Artificial intelligence approaches can be useful techniques in minimizing estimation errors within complex variations of vegetation. We evaluated the performance of Random Forest® regression tree and Artificial Neural Network procedures in modelling stem taper. Diameters and volume outside bark were compared to a traditional taper-based equation across a tropical Brazilian savanna, a seasonal semi-deciduous forest and a rainforest. Neural network models were found to be more accurate than the traditional taper equation. Random forest showed trends in the residuals from the diameter prediction and provided the least precise and accurate estimations for all forest types. This study provides insights into the superiority of a neural network, which provided advantages regarding the handling of local effects. PMID:27187074

  1. Artificial Intelligence Procedures for Tree Taper Estimation within a Complex Vegetation Mosaic in Brazil.

    PubMed

    Nunes, Matheus Henrique; Görgens, Eric Bastos

    2016-01-01

    Tree stem form in native tropical forests is very irregular, posing a challenge to establishing taper equations that can accurately predict the diameter at any height along the stem and subsequently merchantable volume. Artificial intelligence approaches can be useful techniques in minimizing estimation errors within complex variations of vegetation. We evaluated the performance of Random Forest® regression tree and Artificial Neural Network procedures in modelling stem taper. Diameters and volume outside bark were compared to a traditional taper-based equation across a tropical Brazilian savanna, a seasonal semi-deciduous forest and a rainforest. Neural network models were found to be more accurate than the traditional taper equation. Random forest showed trends in the residuals from the diameter prediction and provided the least precise and accurate estimations for all forest types. This study provides insights into the superiority of a neural network, which provided advantages regarding the handling of local effects.

  2. Taper Functions for Predicting Product Volumes in Natural Shortleaf Pines

    Treesearch

    Robert M. Farrar; Paul A. Murphy

    1987-01-01

    Taper (stem-profile) functions are presented for natural shortleaf pine (Pinus echinata Mill.) trees growing in the West Gulf area. These functions, when integrated, permit the prediction of volume between any two heights on a stem and, conversely by iteration, the volume between any two diameters on a stem. Examples are given of use of the functions...

  3. Taper-based system for estimating stem volumes of upland oaks

    Treesearch

    Donald E. Hilt

    1980-01-01

    A taper-based system for estimating stem volumes is developed for Central States upland oaks. Inside bark diameters up the stem are predicted as a function of dbhib, total height, and powers and relative height. A Fortran IV computer program, OAKVOL, is used to predict cubic and board-foot volumes to any desired merchantable top dib. Volumes of...

  4. Effects of Prosthesis Stem Tapers on Stress Distribution of Cemented Hip Arthroplasty

    NASA Astrophysics Data System (ADS)

    Abdullah, Abdul Halim; Nor, Mohd Asri Mohd; Saman, Alias Mohd; Tamin, Mohd Nasir; Kadir, Mohammed Rafiq Abdul

    2010-10-01

    Aseptic loosening effects are critical issues in encouraging long term stability of cemented hip arthroplasty. Stress shielding is believed to be an important factor that contributes to the aseptic loosening problems. The numerous changes in the prosthesis stem design are intended to minimize the stress shielding and aseptic loosening problems and to improve the long term performance of the implants. In this study, the stress distribution in cemented hip arthroplasty is established using finite element method. The taper of the prosthesis is designed to be 3° at anterior/posterior, 3° at medial/lateral and 10° from wide lateral to narrow medial. Major muscle loads and contact forces are simulated for walking (toe-off phase) and stair climbing load cases. Effects of prosthesis stem tapers on the resulting stress distribution are investigated. Results show that compressive stress dominates in the medial plane while tensile stress in the lateral plane of the femur. The corresponding stress levels of intact femur for walking and stair-climbing load cases are 22 and 29 MPa, respectively. The magnitude of Tresca stress for the THA femur in stair-climbing load case remains higher in the region of 85 MPa while the walking load case induces around 40 MPa. The stress range in the straight and single taper stem prosthesis is lower than 260 MPa, while localized Tresca stress is in the order of the yield strength of Ti-6Al-4V alloy for double and triple taper stem design.

  5. A combined experimental and finite element approach to analyse the fretting mechanism of the head-stem taper junction in total hip replacement.

    PubMed

    Bitter, Thom; Khan, Imran; Marriott, Tim; Lovelady, Elaine; Verdonschot, Nico; Janssen, Dennis

    2017-09-01

    Fretting corrosion at the taper interface of modular hip implants has been implicated as a possible cause of implant failure. This study was set up to gain more insight in the taper mechanics that lead to fretting corrosion. The objectives of this study therefore were (1) to select experimental loading conditions to reproduce clinically relevant fretting corrosion features observed in retrieved components, (2) to develop a finite element model consistent with the fretting experiments and (3) to apply more complicated loading conditions of activities of daily living to the finite element model to study the taper mechanics. The experiments showed similar wear patterns on the taper surface as observed in retrievals. The finite element wear score based on Archard's law did not correlate well with the amount of material loss measured in the experiments. However, similar patterns were observed between the simulated micromotions and the experimental wear measurements. Although the finite element model could not be validated, the loading conditions based on activities of daily living demonstrate the importance of assembly load on the wear potential. These findings suggest that finite element models that do not incorporate geometry updates to account for wear loss may not be appropriate to predict wear volumes of taper connections.

  6. Biomass and Taper for Trees in Thinned and Unthinned Longleaf Pine Plantations

    Treesearch

    Charles E. Thomas; Bernard R. Parresol; Kim H. N. Le; Richard E. Lohrey

    1995-01-01

    Longleafpine (Pinus palustris Mill.) trees growing in thinned plantation studies in Louisiana and Texas and unthinned stands from the Louisiana sites were sampled for establishing taper, volume, and specific gravity. Stem analysis data were collected on 147 stems ranging in age from 30 to 50 yr. Analyses of covariance (ANCOVAs) were employed to...

  7. Use of three-point taper systems in timber cruising

    Treesearch

    James W. Flewelling; Richard L. Ernst; Lawrence M. Raynes

    2000-01-01

    Tree volumes and profiles are often estimated as functions of total height and DBH. Alternative estimators include form-class methods, importance sampling, the centroid method, and multi-point profile (taper) estimation systems; all of these require some measurement or estimate of upper stem diameters. The multi-point profile system discussed here allows for upper stem...

  8. Early Experience with a Short, Tapered Titanium Porous Plasma Sprayed Stem with Updated Design.

    PubMed

    Lombardi, Adolph V; Manocchio, Antonio G; Berend, Keith R; Morris, Michael J; Adams, Joanne B

    2018-06-01

    Short stem femoral components in primary total hip arthroplasty (THA) have increased in popularity since the advent of minimally invasive surgical techniques. The concept of a short stem is particularly compatible with tapered designs where the goal is to offload forces proximally in the femur. The purpose of this retrospective review was to review our early experience with a short, tapered titanium femoral component with updated design features. Beginning in November 2011 through February 2012, 92 consented patients (93 hips), at a single center, were treated with primary cementless THA using a short stem, tapered femoral component (Taperloc® Complete Microplasty; Zimmer Biomet, Warsaw, Indiana) and were available for review with a minimum two-year follow-up. Mean patient age at surgery was 63.2 years and body mass index (BMI) was 30.8 kg/m2. Mean stem length used was 110.3mm (range, 95-125). Mean follow-up was 4.5 years (2-6). Harris hip scores improved from 52.5 preoperatively to 84.7 at most recent. One stem was revised the same day for periprosthetic fracture. One patient with early infection was treated with single-stage exchange followed by recurrence that was treated successfully with two-stage exchange. A non-healing wound in one patient was treated with incision and debridement. Radiographic assessment demonstrated no evidence of loosening, osteolysis, distal hypertrophy, or pedestal formation in any hip, and all components appeared well fixed and in appropriate alignment. In this series of patients treated with primary THA using a short, tapered titanium porous plasma-sprayed femoral component with updated design features, good results were achieved with a low incidence of complications and revision. No aseptic loosening or osteolysis has occurred. Radiographic assessment was excellent for all patients.

  9. Total Hip Arthroplasty Using a Polished Tapered Cemented Stem in Hereditary Multiple Exostosis

    PubMed Central

    Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko

    2016-01-01

    A 61-year-old Japanese man underwent right total hip arthroplasty for hereditary multiple exostosis. At first presentation, he had suffered from coxalgia for a long time. On radiographic images, there was a gigantic femoral head, increased shaft angle, and large diameter of the femoral neck. He had also developed coxarthrosis and severe pain of the hip joint. The transformation of the proximal femur bone causes difficulty in setting a cementless total hip prosthesis. Therefore, total hip arthroplasty using a cemented polished tapered stem was performed via a direct lateral approach. Using a cemented polished tapered stem allowed us to deal with the femoral bone transformation and bone substance defectiveness due to exostosis and also minimized the invasiveness of the operation. PMID:27127668

  10. The C-stem in clinical practice: fifteen-year follow-up of a triple tapered polished cemented stem.

    PubMed

    Purbach, Bodo; Kay, Peter R; Siney, Paul D; Fleming, Patricia A; Wroblewski, B Michael

    2013-09-01

    The triple tapered polished cemented stem, C-Stem, introduced in 1993 was based on the original Charnley concept of the "flat back" polished stem. We present our continuing experience with the C-Stem in 621 consecutive primary arthroplasties implanted into 575 patients between 1993 and 1997. Four hundred and eighteen arthroplasties had a clinical and radiological follow-up past 10 years with a mean follow-up of 13 years (10-15). There were no revisions for stem loosening but 2 stems were revised for fracture - both with a defective cement mantle proximally. The stem design and the surgical technique support the original Charnley concept of limited stem subsidence within the cement mantle and the encouraging results continue to stand as a credit to Sir John Charnley's original philosophy. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Asymptomatic Pseudotumors in Patients with Taper Corrosion of a Dual-Taper Modular Femoral Stem: MARS-MRI and Metal Ion Study.

    PubMed

    Kwon, Young-Min; Khormaee, Sariah; Liow, Ming Han Lincoln; Tsai, Tsung-Yuan; Freiberg, Andrew A; Rubash, Harry E

    2016-10-19

    Modularity in total hip arthroplasty facilitates intraoperative restoration of patient anatomy. Although dual-taper modular total hip arthroplasty offers potential advantages for optimizing the hip center of rotation, it has been associated with modular taper corrosion. This corrosion has led to adverse local tissue reactions (pseudotumors) at the neck-stem junction and elevated metal-ion levels. However, the occurrence of taper-corrosion-related pseudotumors in patients who remain asymptomatic following total hip arthroplasty with a dual-taper modular femoral stem remains largely unknown. The aims of this study were (1) to determine the prevalence of asymptomatic pseudotumors by utilizing metal artifact reduction sequence magnetic resonance imaging (MARS-MRI) and (2) compare serum metal-ion levels between symptomatic and asymptomatic patients with a dual-taper modular stem total hip replacement. We performed a retrospective cross-sectional study of 97 consecutive patients who had been treated with a dual-taper modular femoral stem total hip arthroplasty. Eighty-three patients were stratified into symptomatic and asymptomatic groups and evaluated with MARS-MRI, measurement of serum metal-ion levels, and the University of California at Los Angeles (UCLA) functional hip score. The prevalence of pseudotumors as determined with MARS-MRI was 15% in our asymptomatic patients and 36% in the overall cohort. The median serum cobalt level and cobalt/chromium ratio were significantly higher in patients with a pseudotumor than in those without a pseudotumor (8.0 versus 2.0 μg/L [p = 0.004] and 10.3 versus 2.4 μg/L [p = 0.012], respectively). However, there was no significant difference in the serum cobalt level or cobalt/chromium ratio between symptomatic patients with a pseudotumor and asymptomatic patients with a pseudotumor (7.6 versus 6.2 μg/L [p = 0.37] and 8.3 versus 10.6 μg/L [p = 0.46], respectively). The UCLA scores of asymptomatic patients with a pseudotumor were similar to those of patients without a pseudotumor (6.7 versus 6.6). The prevalence of asymptomatic taper-corrosion-related pseudotumors on MARS-MRI in this study demonstrated that the absence of symptoms does not exclude the presence of adverse local tissue reactions. Elevated cobalt levels and cobalt/chromium ratios were associated with the presence of pseudotumors in asymptomatic and symptomatic patients. Cross-sectional imaging such as MARS-MRI is indicated for patients with elevated metal-ion levels. A longitudinal study is required to determine whether asymptomatic patients with taper-corrosion-related pseudotumors will develop symptoms with time. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  12. Tapered stems one-third proximally coated have higher complication rates than cylindrical two-third coated stems in patients with high hip dislocation undergoing total hip arthroplasty with step-cut shortening osteotomy.

    PubMed

    Ozden, V Emre; Dikmen, G; Beksac, B; Tozun, I Remzi

    2017-06-01

    The results of cementless stems in total hip arthroplasty (THA) done because of congenital dislocation with step-cut osteotomy is not well known, particularly the influence of the design and the role of extent of porous coating. Therefore we performed a retrospective study to evaluate the mid to long-term results THA performed with a single type acetabular component and different geometry and fixation type stems with ceramic bearings in the setting of step-cut subtrochanteric osteotomy in high hip dislocated (HHD) patients. We asked if the stem type affect the outcomes in terms of (1) intra and postoperative complication rates (2) radiographic outcomes (3) prosthesis survival in step-cut subtrochanteric shortening osteotomy. The type of the stem, whether cylindrical or tapered does not affect the outcome if the femoral canal fit and fill is obtained and the step-cut femoral shortening osteotomy is primarily fixed. Forty-five hips in 35 patients with a mean follow up of 10 years (range, 7-14 years) were evaluated. The single type cementless cup was placed at the level of the true acetabulum, a step-cut shortening femoral osteotomy was performed and reconstruction was performed with two different types of tapered stem in twenty-two hips (Synergy™ and Image™ proximally coated, Smith and Nephew, Menphis, TN, USA) and one type of cylindrical stem (Echelon™ with 2/3 coated, Smith and Nephew, Menphis, TN, USA) in twenty-three hips. Harris hip scores (HHS) and a University of California Los Angeles (UCLA) activity scores were calculated for all patients and successive X-rays were evaluated regarding component loosening and osteolysis, along with complications related to bearing, step-cut osteotomy and stem types. Forty-one hips (91%) had good and excellent clinical outcome according to HHS. The mean UCLA activity scores improved from 3.2±0.6 points (range, 2-4) preoperatively to 6.3 points±0.5 (range, 5-7) at the latest follow-up. The mean femoral shortening was 36±10mm (range, 20-65mm). Four (9%) dislocations were observed. There were five (11%) intra-operative femoral fractures and three (7%) cases of non-union, which were observed in tapered stems. Cylindrical stems had superior neutral alignment primarily. With any stem revision as the end point, cylindrical stems had a higher survival rate (100%) than all tapered stems (82%; 95% confident interval [CI] 77-97%) at ten years. With any revision as the end point, the 10-year survival rate for acetabular component (Reflection-Ceramic Interfit) and for femoral components were 98% (95% CI, 85-99%) and 91% (95% CI, 78-97%), respectively. There were more implant related complications in HHD patients undergoing THA when tapered stems with 1/3 proximal coating were used to reconstruct a step cut osteotomized femur, compared to cylindrical stems 2/3 coated. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  13. A Compatible Stem Taper-Volume-Weight System For Intensively Managed Fast Growing Loblolly Pine

    Treesearch

    Yugia Zhang; Bruce E. Borders; Robert L Bailey

    2002-01-01

    eometry-oriented methodology yielded a compatible taper-volume-weight system of models whose parameters were estimated using data from intensively managed loblolly pine (Pinus taeda L.) plantations in the lower coastal plain of Georgia. Data analysis showed that fertilization has significantly reduced taper (inside and outside bark) on the upper...

  14. Clinical significance of corrosion of cemented femoral stems in metal-on-metal hips: a retrieval study.

    PubMed

    Hothi, Harry S; Berber, Reshid; Panagiotopoulos, Andreas C; Whittaker, Robert K; Rhead, Camilla; Skinner, John A; Hart, Alister J

    2016-11-01

    The clinical significance of corrosion of cemented femoral stems is unclear. The purpose of this retrieval study was to: (1) report on corrosion at the stem-cement interface and (2) correlate these findings with clinical data. We analysed cemented stems (n = 36) composed of cobalt-chromium (CoCr) and stainless steel (SS) in a series of revised metal-on-metal hips. We performed detailed inspection of each stem to assess the severity of corrosion at the stem-cement interface using a scale of 1 (low) to 5 (severe). We assessed the severity of corrosion at each stem trunnion and measured wear rates at the head taper and bearing surfaces. We used non-parametric tests to determine the significance of differences between the CoCr and SS stems in relation to: (1) pre-revision whole blood Co and Cr metal ion levels, (2) trunnion corrosion, (3) bearing surface wear and (4) taper material loss. The corrosion scores of CoCr stems were significantly greater than SS stems (p < 0.01). Virtually all stem trunnions in both alloy groups had minimal evidence of corrosion. The median pre-revision Co levels of implants with CoCr stems were significantly greater than the SS stems (p < 0.01). There was no significant difference in relation to pre-revision Cr levels (p = 0.521). There was no significant difference between the two stem types in relation to bearing wear (p = 0.926) or taper wear (p = 0.148). Severe corrosion of cemented femoral stems is a common finding at our retrieval centre; surgeons should consider corrosion of CoCr stems as a potential source of metal ions when revising a hip.

  15. Damage Patterns at the Head-Stem Taper Junction Helps Understand the Mechanisms of Material Loss.

    PubMed

    Hothi, Harry S; Panagiotopoulos, Andreas C; Whittaker, Robert K; Bills, Paul J; McMillan, Rebecca A; Skinner, John A; Hart, Alister J

    2017-01-01

    Material loss at the taper junction of metal-on-metal total hip arthroplasties has been implicated in their early failure. The mechanisms of material loss are not fully understood; analysis of the patterns of damage at the taper can help us better understand why material loss occurs at this junction. We mapped the patterns of material loss in a series of 155 metal-on-metal total hip arthroplasties received at our center by scanning the taper surface using a roundness-measuring machine. We examined these material loss maps to develop a 5-tier classification system based on visual differences between different patterns. We correlated these patterns to surgical, implant, and patient factors known to be important for head-stem taper damage. We found that 63 implants had "minimal damage" at the taper (material loss <1 mm 3 ), and the remaining 92 implants could be categorized by 4 distinct patterns of taper material loss. We found that (1) head diameter and (2) time to revision were key significant variables separating the groups. These material loss maps allow us to suggest different mechanisms that dominate the cause of the material loss in each pattern: (1) corrosion, (2) mechanically assisted corrosion, or (3) intraoperative damage or poor size tolerances leading to toggling of trunnion in taper. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Fretting and Corrosion in Modular Shoulder Arthroplasty: A Retrieval Analysis

    PubMed Central

    Panzram, Benjamin

    2016-01-01

    Tribocorrosion in taper junctions of retrieved anatomic shoulder arthroplasty implants was evaluated. A comparison of the tribocorrosion between cobalt-chromium and titanium alloy stems was conducted and the observations were correlated with the individual's clinical data. Adverse effects caused by metal debris and subsequent elevated serum metal ion levels are frequently reported in total hip arthroplasty. In total shoulder arthroplasty, to date only a small number of retrieval analyses are available and even fewer address the issue of tribocorrosion at the taper junctions. A total of 36 retrieved hemiarthroplasties and total shoulder arthroplasties were assessed using the modified Goldberg score. The prevalence of fretting and corrosion was confirmed in this cohort. Titanium stems seem to be more susceptible to damage caused by tribocorrosion than cobalt-chromium stems. Furthermore, stemless designs offered less tribocorrosion at the taper junction than stemmed designs. A weak correlation between time to revision and increased levels of tribocorrosion was seen. Whether or not tribocorrosion can lead to adverse clinical reactions and causes failure of shoulder arthroplasties remains to be examined. PMID:27433471

  17. Fretting and Corrosion Damage in Taper Adapter Sleeves for Ceramic Heads: A Retrieval Study.

    PubMed

    MacDonald, Daniel W; Chen, Antonia F; Lee, Gwo-Chin; Klein, Gregg R; Mont, Michael A; Kurtz, Steven M; Cates, Harold E; Kraay, Matthew J; Rimnac, Clare M

    2017-09-01

    During revision surgery with a well-fixed stem, a titanium sleeve can be used in conjunction with a ceramic head to achieve better stress distribution across the taper surface. In vitro testing suggests that corrosion is not a concern in sleeved ceramic heads; however, little is known about the in vivo fretting corrosion of the sleeves. The purpose of this study was to investigate fretting corrosion in sleeved ceramic heads in retrieved total hip arthroplasties. Thirty-seven sleeved ceramic heads were collected during revision. The femoral heads and sleeves were implanted 0.0-3.3 years. The implants were revised predominantly for instability, infection, and loosening. Fifty percent of the retrievals were implanted during a primary surgery. Fretting corrosion was assessed using the Goldberg-Higgs semiquantitative scoring system. Mild-to-moderate fretting corrosion scores (score = 2-3) were observed in 92% of internal tapers, 19% of external tapers, and 78% of the stems. Severe fretting corrosion was observed in 1 stem trunnion that was previously retained during revision surgery and none of the retrieved sleeves. There was no difference in corrosion damage of sleeves used in primary or revision surgery. The fretting corrosion scores in this study were predominantly mild and lower than reported fretting scores of cobalt-chrome heads in metal-on-polyethylene bearings. Although intended for use in revisions, we found that the short-term in vivo corrosion behavior of the sleeves was similar in both primary and revision surgery applications. From an in vivo corrosion perspective, sleeves are a reasonable solution for restoring the stem taper during revision surgery. Copyright © 2017. Published by Elsevier Inc.

  18. Difference in Postoperative Periprosthetic Bone Mineral Density Changes Between 3 Major Designs of Uncemented Stems: A 3-Year Follow-Up Study.

    PubMed

    Inaba, Yutaka; Kobayashi, Naomi; Oba, Masatoshi; Ike, Hiroyuki; Kubota, So; Saito, Tomoyuki

    2016-08-01

    Although few studies have examined the direct effect of stress shielding on clinical outcomes, periprosthetic bone loss due to stress shielding is still an issue of concern, especially when physicians perform uncemented total hip arthroplasty (THA) in younger patients. Differences in femoral stem design may affect the degree of postoperative stress shielding. Therefore, the characteristics of the behavior for stress shielding of each type of femoral stem should be determined. This study compares differences in bone mineral density (BMD) change in the femur after primary THA between 3 major types of uncemented stems. Among a total of 89 hips, 26 hips received THA with a fit-and-fill type stem (VerSys Fiber Metal MidCoat; Zimmer, Inc, Warsaw, IN), 32 hips received a tapered rectangular Zweymüller-type stem (SL-Plus; Smith & Nephew Inc, Memphis, TN), and 31 received a tapered wedge-type stem (Accolade TMZF; Stryker Orthopaedics, Mahwah, NJ). BMD measurements were performed with a HOLOGIC Discovery device (Hologic Inc, Waltham, MA). BMD in the medial-proximal femur was maintained for 3 years after THA in the group with the tapered wedge-type stem. BMD in the lateral-proximal femur was maintained for 3 years after THA in the group with the Zweymüller-type stem. There were no significant differences in the Harris Hip Score among the 3 stem groups preoperatively and 1, 2, and 3 years after surgery. There are clear differences in postoperative BMD loss of the proximal femur among these 3 commonly used uncemented stems. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Segmented polynomial taper equation incorporating years since thinning for loblolly pine plantations

    Treesearch

    A. Gordon Holley; Thomas B. Lynch; Charles T. Stiff; William Stansfield

    2010-01-01

    Data from 108 trees felled from 16 loblolly pine stands owned by Temple-Inland Forest Products Corp. were used to determine effects of years since thinning (YST) on stem taper using the Max–Burkhart type segmented polynomial taper model. Sample tree YST ranged from two to nine years prior to destructive sampling. In an effort to equalize sample sizes, tree data were...

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abdullah, Abdul Halim; Nor, Mohd Asri Mohd; Saman, Alias Mohd

    Aseptic loosening effects are critical issues in encouraging long term stability of cemented hip arthroplasty. Stress shielding is believed to be an important factor that contributes to the aseptic loosening problems. The numerous changes in the prosthesis stem design are intended to minimize the stress shielding and aseptic loosening problems and to improve the long term performance of the implants. In this study, the stress distribution in cemented hip arthroplasty is established using finite element method. The taper of the prosthesis is designed to be 3 deg. at anterior/posterior, 3 deg. at medial/lateral and 10 deg. from wide lateral tomore » narrow medial. Major muscle loads and contact forces are simulated for walking (toe-off phase) and stair climbing load cases. Effects of prosthesis stem tapers on the resulting stress distribution are investigated. Results show that compressive stress dominates in the medial plane while tensile stress in the lateral plane of the femur. The corresponding stress levels of intact femur for walking and stair-climbing load cases are 22 and 29 MPa, respectively. The magnitude of Tresca stress for the THA femur in stair-climbing load case remains higher in the region of 85 MPa while the walking load case induces around 40 MPa. The stress range in the straight and single taper stem prosthesis is lower than 260 MPa, while localized Tresca stress is in the order of the yield strength of Ti-6Al-4V alloy for double and triple taper stem design.« less

  1. Shorter, rough trunnion surfaces are associated with higher taper wear rates than longer, smooth trunnion surfaces in a contemporary large head metal-on-metal total hip arthroplasty system.

    PubMed

    Brock, Timothy M; Sidaginamale, Raghavendra; Rushton, Steven; Nargol, Antoni V F; Bowsher, John G; Savisaar, Christina; Joyce, Tom J; Deehan, David J; Lord, James K; Langton, David J

    2015-12-01

    Taper wear at the head-neck junction is a possible cause of early failure in large head metal-on-metal (LH-MoM) hip replacements. We hypothesized that: (i) taper wear may be more pronounced in certain product designs; and (ii) an increased abductor moment arm may be protective. The tapers of 104 explanted LH-MoM hip replacements revised for adverse reaction to metal debris (ARMD) from a single manufacturer were analyzed for linear and volumetric wear using a co-ordinate measuring machine. The mated stem was a shorter 12/14, threaded trunnion (n=72) or a longer, smooth 11/13 trunnion (n=32). The abductor moment arm was calculated from pre-revision radiographs. Independent predictors of linear and volumetric wear included taper angle, stem type, and the horizontal moment arm. Tapers mated with the threaded 12/14 trunnion had significantly higher rates of volumetric wear (0.402 mm3/yr vs. 0.123 mm3/yr [t=-2.145, p=0.035]). There was a trend to larger abductor moment arms being protective (p=0.055). Design variation appears to play an important role in taper-trunnion junction failure. We recommend that surgeons bear these findings in mind when considering the use of a short, threaded trunnion with a cobalt-chromium head. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  2. Implication of femoral stem on performance of articular surface replacement (ASR) XL total hip arthroplasty.

    PubMed

    Cip, Johannes; von Strempel, Archibald; Bach, Christian; Luegmair, Matthias; Benesch, Thomas; Martin, Arno

    2014-11-01

    Taper junctions of large diameter metal-on-metal femoral heads and femoral stems were described as metal ion generator due to accelerated wear and corrosion. However, literature about the Articular Surface Replacement (ASR) total hip arthroplasty (THA) invariably deals with stems manufactured by DePuy Orthopedics (Warsaw, IN, USA). Nothing is known whether different stems with common 12/14 mm tapers affect failure rate or ion release. 99 ASR THA (88 patients) implanted with CoxaFit or ARGE Geradschaft stems (K-Implant, Hannover, Germany) were retrospectively analyzed. After a mean follow-up of 3.5 years revision rate was 24.5%, mostly due to adverse reaction to metal debris (ARMD). CT scan revealed component loosening in 10.3% and pseudotumoral lesions in 12.6%. Elevated ion concentrations (>7 μg/l) were found in 38.6%. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Fatigue fracture of a proximally modular, distally tapered fluted implant with diaphyseal fixation.

    PubMed

    Buttaro, Martín A; Mayor, Michael B; Van Citters, Douglas; Piccaluga, Francisco

    2007-08-01

    We report and analyze the causes of a fracture in a proximally modular, distally tapered fluted MP stem in a 48-year-old woman (168 cm, 67 kg) with severe proximal bone deficiency. Evidence of fatigue failure with striations initiated laterally was observed in the laser etching of the tensile aspect of the prosthesis. However, metallurgical analysis suggested that laser engraving did not alter the microstructure of the stem. Stress due to the absence of proximal femoral bone support may have been sufficiently high to put this particular stem at risk for fatigue fracture. This important complication should be addressed when choosing this therapeutic option in cases with substantial proximal femoral bone loss. Strut allograft support should be recommended in such cases.

  4. Simple, Flexible, Trigonometric Taper Equations

    Treesearch

    Charles E. Thomas; Bernard R. Parresol

    1991-01-01

    There have been numerous approaches to modeling stem form in recent decades. The majority have concentrated on the simpler coniferous bole form and have become increasingly complex mathematical expressions. Use of trigonometric equations provides a simple expression of taper that is flexible enough to fit both coniferous and hard-wood bole forms. As an illustration, we...

  5. Taper equation and volume tables for plantation-grown red alder.

    Treesearch

    Andrew A. Bluhm; Sean M. Garber; David E. Hibbs

    2007-01-01

    A taper equation and associated tables are presented for red alder (Alnus rubra Bong.) trees grown in plantations. The data were gathered from variable-density experimental plantations throughout the Pacific Northwest. Diameter inside bark along the stem was fitted to a variable exponent model form by using generalized nonlinear least squares and a...

  6. Compatible taper equation for loblolly pine

    Treesearch

    J. P. McClure; R. L. Czaplewski

    1986-01-01

    Cao's compatible, segmented polynomial taper equation (Q. V. Cao, H. E. Burkhart, and T. A. Max. For. Sci. 26: 71-80. 1980) is fitted to a large loblolly pine data set from the southeastern United States. Equations are presented that predict diameter at a given height, height to a given top diameter, and volume below a given position on the main stem. All...

  7. Undisplaced Intraoperative Fracture Presenting as Early Dislocation with Tapered Wedge Stems in Total Hip Arthroplasty - Case Series and Review of Literature

    PubMed Central

    Reddy, A V Gurava; Eachempati, Krishna Kiran; Mugalur, Aakash; Suchinder, A; Rao, V B N Prasad; Kamurukuru, Nalanda

    2017-01-01

    Introduction: Periprosthetic fractures and dislocation in the early post-operative period can be disastrous both for the surgeon and the patient. However, undisplaced periprosthetic fractures presenting with dislocation is uncommon. We describe successful management of two cases (one bilateral dislocation and one unilateral dislocation) of undisplaced iatrogenic fractures in total hip arthroplasty (THA) presenting as early dislocation. Case Report: Case 1 was a 45-year-old female with osteoarthritis of hip secondary to developmental dysplasia of the hip with bilateral early nontraumatic dislocation with bilateral identical periprosthetic fracture. It was managed by revision to long stem and encirclage wiring. Case 2 presented with early dislocation in the 2nd week post THA. We found an intertrochanteric fracture intra-operatively with unstable implant. Acetabular component and femoral component revision were done with reconstruction of the greater trochanter. Discussion: These fractures could be occult iatrogenic fractures characteristic of taper wedge stems which presented as early nontraumatic dislocation in the post-operative period. The prosthesis subsidence, loss of muscle tension and change of version might be the factors leading to dislocation. Conclusion: Unrecognized incomplete intraoperative fracture can occur with tapered wedge uncemented stems which can present as a dislocation in the immediate post-operative period. This will require early revision of the femoral component. PMID:29051875

  8. Modeling stem profile of Triadica Sebifera in southern forestlands of Mississippi

    Treesearch

    Nana Tian; Zhaofei Fan

    2016-01-01

    Chinese tallow (Triadica sebifera) is one of the most aggressive invasive species in the southern forestlands of United States. To explore the stem taper of tallow, outside-and-inside bark stem profile equations were fitted using Max and Burkhart (1976), Cao (2009) modified Max and Burkhart, andClark, Souter, and Schlaegel (1991) segmented...

  9. Intensive management influence on Douglas-fir stem form, branch characteristics, and simulated product recovery

    Treesearch

    A.R. Weiskittel; R.A. Monserud; R. Rose; E.C. Turnblom; Douglas A. Maguire

    2006-01-01

    Intensive management may adversely affect lumber yield and quality by increasing knot size and creating a more conical stem form with a greater average rate of taper. This study was initiated to examine the impact of management on simulated lumber yield and quality. Stem diameter and branch size and location of 223 Pseudotsuga menziesii (Mirb.)...

  10. Ultraviolet, visible, and infrared laser delivery using laser-to-fiber coupling via a grazing-incidence-based hollow taper

    NASA Astrophysics Data System (ADS)

    Ilev, Ilko K.; Waynant, Ronald W.

    2001-01-01

    We present a novel all-optical-waveguide method for ultraviolet (UV), visible (VIS) and infrared (IR) laser delivery including a lens-free method of laser-to-fiber coupling using a simple uncoated glass hollow taper. Based on the grazing incidence effect, the hollow taper provides a way of direct launching, without any intermediate focusing elements, high power laser radiation into delivery fibers. Because of the mutual action of the nearly parallel laser excitation, the mode coupling process, and mode filtering effect, the hollow taper serves as a mode converter that transforms the highly multimode profile of the input laser emission into a high-quality Gaussian-shaped profile at the taper output. When the grazing incidence effect of the taper is applied to laser delivery, the maintenance of high reflectance coefficients in a wide spectral region allows to utilize the same uncoated hollow taper for laser radiation in the UV, VIS and IR ranges. Applying the experimental hollow-taper based delivery systems, we obtain high laser- to-taper and taper-to-fiber coupling efficiencies.

  11. Basal area increment and growth efficiency as functions of canopy dynamics and stem mechanics

    Treesearch

    Thomas J. Dean

    2004-01-01

    Crown and canopy structurecorrelate with growth efficiency and also determine stem size and taper as described by the uniform stress principle of stem formation. A regression model was derived from this principle that expresses basal area increment in terms of the amount and vertical distribution of leaf area and change in these variables during a growth period. This...

  12. High risk of early periprosthetic fractures after primary hip arthroplasty in elderly patients using a cemented, tapered, polished stem.

    PubMed

    Brodén, Cyrus; Mukka, Sebastian; Muren, Olle; Eisler, Thomas; Boden, Henrik; Stark, André; Sköldenberg, Olof

    2015-04-01

    Postoperative periprosthetic femoral fracture (PPF) after hip arthroplasty is associated with considerable morbidity and mortality. We assessed the incidence and characteristics of periprosthetic fractures in a consecutive cohort of elderly patients treated with a cemented, collarless, polished and tapered femoral stem (CPT). In this single-center prospective cohort study, we included 1,403 hips in 1,357 patients (mean age 82 (range 52-102) years, 72% women) with primary osteoarthritis (OA) or a femoral neck fracture (FNF) as indication for surgery (367 hips and 1,036 hips, respectively). 64% of patients were ASA class 3 or 4. Hip-related complications and need for repeat surgery were assessed at a mean follow-up time of 4 (1-7) years. A Cox regression analysis was used to evaluate risk factors associated with PPF. 47 hips (3.3%) sustained a periprosthetic fracture at median 7 (2-79) months postoperatively; 41 were comminute Vancouver B2 or complex C-type fractures. The fracture rate was 3.8% for FNF patients and 2.2% for OA patients (hazard ratio (HR) = 4; 95% CI: 1.3-12). Patients > 80 years of age also had a higher risk of fracture (HR = 2; 95% CI: 1.1-4.5). We found a high incidence of early PPF associated with the CPT stem in this old and frail patient group. A possible explanation may be that the polished tapered stem acts as a wedge, splitting the femur after a direct hip contusion. Our results should be confirmed in larger, registry-based studies, but we advise caution when using this stem for this particular patient group.

  13. High risk of early periprosthetic fractures after primary hip arthroplasty in elderly patients using a cemented, tapered, polished stem

    PubMed Central

    Brodén, Cyrus; Mukka, Sebastian; Muren, Olle; Eisler, Thomas; Boden, Henrik; Stark, André; Sköldenberg, Olof

    2015-01-01

    Background and purpose Postoperative periprosthetic femoral fracture (PPF) after hip arthroplasty is associated with considerable morbidity and mortality. We assessed the incidence and characteristics of periprosthetic fractures in a consecutive cohort of elderly patients treated with a cemented, collarless, polished and tapered femoral stem (CPT). Patients and methods In this single-center prospective cohort study, we included 1,403 hips in 1,357 patients (mean age 82 (range 52–102) years, 72% women) with primary osteoarthritis (OA) or a femoral neck fracture (FNF) as indication for surgery (367 hips and 1,036 hips, respectively). 64% of patients were ASA class 3 or 4. Hip-related complications and need for repeat surgery were assessed at a mean follow-up time of 4 (1–7) years. A Cox regression analysis was used to evaluate risk factors associated with PPF. Results 47 hips (3.3%) sustained a periprosthetic fracture at median 7 (2–79) months postoperatively; 41 were comminute Vancouver B2 or complex C-type fractures. The fracture rate was 3.8% for FNF patients and 2.2% for OA patients (hazard ratio (HR) = 4; 95% CI: 1.3–12). Patients > 80 years of age also had a higher risk of fracture (HR = 2; 95% CI: 1.1–4.5). Interpretation We found a high incidence of early PPF associated with the CPT stem in this old and frail patient group. A possible explanation may be that the polished tapered stem acts as a wedge, splitting the femur after a direct hip contusion. Our results should be confirmed in larger, registry-based studies, but we advise caution when using this stem for this particular patient group. PMID:25280133

  14. Femoral stem size mismatch in women undergoing total hip arthroplasty.

    PubMed

    Dundon, John M; Felberbaum, Dvorah Leah; Long, William J

    2018-06-01

    Total hip arthroplasty (THA) is a highly successful surgery with a high prevalence in women. Women have been noted to have smaller proximal femoral anatomy and decreased bone strength compared to males. The goal of our study was to define the size discrepancy in femoral stem implants between men and women using a metaphyseal fitting single taper stem. We retrospectively reviewed the THA's performed by a single surgeon over the previous two years. Data was extracted from operative reports regarding stem size, neck length and offset, and conversion to a different type of stem. This data was reviewed with confidence intervals and a t -test was performed for independent samples with a p < 0.05 being determined significant. We analyzed the data from 276 THA's performed (129 in men, and 147 in women). Women were noted to be associated with smaller stem sizes compared to men (37.67% in women, 6.11% in men), with 7.48% of women requiring conversion to a different type of implant. There was a significant difference in mean stem size (9.21 in men, 6.70 in women, p < 0.0001). Women also required reduced neck options significantly more often than men (38.97% in women, 9.29% in men, p < 0.0001). Review of femoral stem sizes reveals that current femoral stem sizing may not appropriately account for women and alternative stem options should be available if using a metaphyseal fitting single tapered stems. Future consideration should be given to more anatomic female sized femoral stems or alternative options should be available.

  15. Lower periprosthetic bone loss and good fixation of an ultra-short stem compared to a conventional stem in uncemented total hip arthroplasty.

    PubMed

    Salemyr, Mats; Muren, Olle; Ahl, Torbjörn; Bodén, Henrik; Eisler, Thomas; Stark, André; Sköldenberg, Olof

    2015-01-01

    We hypothesized that an ultra-short stem would load the proximal femur in a more physiological way and could therefore reduce the adaptive periprosthetic bone loss known as stress shielding. 51 patients with primary hip osteoarthritis were randomized to total hip arthroplasty (THA) with either an ultra-short stem or a conventional tapered stem. The primary endpoint was change in periprosthetic bone mineral density (BMD), measured with dual-energy x-ray absorptiometry (DXA), in Gruen zones 1 and 7, two years after surgery. Secondary endpoints were change in periprosthetic BMD in the entire periprosthetic region, i.e. Gruen zones 1 through 7, stem migration measured with radiostereometric analysis (RSA), and function measured with self-administered functional scores. The periprosthetic decrease in BMD was statistically significantly lower with the ultra-short stem. In Gruen zone 1, the mean difference was 18% (95% CI: -27% to -10%). In zone 7, the difference was 5% (CI: -12% to -3%) and for Gruen zones 1-7 the difference was also 5% (CI: -9% to -2%). During the first 6 weeks postoperatively, the ultra-short stems migrated 0.77 mm more on average than the conventional stems. 3 months after surgery, no further migration was seen. The functional scores improved during the study and were similar in the 2 groups. Up to 2 years after total hip arthroplasty, compared to the conventional tapered stem the ultra-short uncemented anatomical stem induced lower periprosthetic bone loss and had equally excellent stem fixation and clinical outcome.

  16. Defining stem profile model for wood valuation of red pine in Ontario and Michigan with consideration of stand density influence on tree taper

    Treesearch

    W. T. Zakrzewski; M. Penner; D. W. MacFarlane

    2007-01-01

    As part of the Canada-United States Great Lakes Stem Profile Modelling Project, established to support the local timber production process and to enable cross-border comparisons of timber volumes, here we present results of fitting Zakrzewski's (1999) stem profile model for red pine (Pinus resinosa Ait.) growing in Michigan, United States, and...

  17. Computing factors of safety against wind-induced tree stem damage.

    PubMed

    Niklas, K J

    2000-04-01

    The drag forces, bending moments and stresses acting on stems differing in size and location within the mechanical infrastructure of a large wild cherry (Prunus serotina Ehrh.) tree are estimated and used to calculate the factor of safety against wind-induced mechanical failure based on the mean breaking stress of intact stems and samples of wood drawn from this tree. The drag forces acting on stems are calculated based on stem projected areas and field measurements of wind speed taken within the canopy and along the length of the trunk. The bending moments and stresses resulting from these forces are shown to increase basipetally in a nearly log-log linear fashion toward the base of the tree. The factor of safety, however, varies in a sinusoidal manner such that the most distal stems have the highest factors of safety, whereas stems of intermediate location and portions of the trunk near ground level have equivalent and much lower factors of safety. This pattern of variation is interpreted to indicate that, as a course of normal growth and development, trees similar to the one examined in this study maintain a cadre of stems prone to wind-induced mechanical damage that can reduce the probability of catastrophic tree failure by reducing the drag forces acting on older portions of the tree. Comparisons among real and hypothetical stems with different taper experiencing different vertical wind speed profiles show that geometrically self-similar stems have larger factors of safety than stems tapering according to elastic or stress self-similarity, and that safety factors are less significantly influenced by the 'geometry' of the wind-profile.

  18. Trunnionosis: Does Head Size Affect Fretting and Corrosion in Total Hip Arthroplasty?

    PubMed

    Del Balso, Christopher; Teeter, Matthew G; Tan, Sok Chuen; Howard, James L; Lanting, Brent A

    2016-10-01

    Wear and tribocorrosion at the modular head-neck taper interface may be a cause of failure in metal-on-polyethylene total hip arthroplasty (THA). The present investigation endeavored to elucidate the effect of femoral head diameter on fretting and corrosion in retrieved head-neck tapers. A retrieval analysis of THA prostheses in vivo for a minimum of 1 year was performed. Twenty-three femoral heads of 32-mm diameter were matched with 28-mm heads based on time in vivo and head length (-3 mm to +8 mm). All included implants featured a single taper design from a single manufacturer. Fretting and corrosion damage scoring was performed for each implant under stereomicroscopic visualization. Head diameter was observed to affect fretting (P = .01), with 32-mm femoral heads exhibiting greater total fretting scores than 28-mm heads. Fretting damage was greatest (P = .01) in the central concentric zone of the femoral head bore tapers, regardless of head diameter, length, or stem offset. No significant effect on total corrosion scores was observed for any head or stem variable. Retrieved implant total corrosion scores were positively correlated (ρ = 0.51, P < .001) with implantation time. Increased femoral head diameter in THA may produce greater fretting damage owing to and increased head-neck moment arm. There is no associated increase in corrosion with 28-mm and 32-mm heads of this taper design. The longer a THA prosthesis is implanted, the greater the risk of damage due to corrosion. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. The effect of frictional torque and bending moment on corrosion at the taper interface : an in vitro study.

    PubMed

    Panagiotidou, A; Meswania, J; Osman, K; Bolland, B; Latham, J; Skinner, J; Haddad, F S; Hart, A; Blunn, G

    2015-04-01

    The aim of this study was to assess the effect of frictional torque and bending moment on fretting corrosion at the taper interface of a modular femoral component and to investigate whether different combinations of material also had an effect. The combinations we examined were 1) cobalt-chromium (CoCr) heads on CoCr stems 2) CoCr heads on titanium alloy (Ti) stems and 3) ceramic heads on CoCr stems. In test 1 increasing torque was imposed by offsetting the stem in the anteroposterior plane in increments of 0 mm, 4 mm, 6 mm and 8 mm when the torque generated was equivalent to 0 Nm, 9 Nm, 14 Nm and 18 Nm. In test 2 we investigated the effect of increasing the bending moment by offsetting the application of axial load from the midline in the mediolateral plane. Increments of offset equivalent to head + 0 mm, head + 7 mm and head + 14 mm were used. Significantly higher currents and amplitudes were seen with increasing torque for all combinations of material. However, Ti stems showed the highest corrosion currents. Increased bending moments associated with using larger offset heads produced more corrosion: Ti stems generally performed worse than CoCr stems. Using ceramic heads did not prevent corrosion, but reduced it significantly in all loading configurations. ©2015 The British Editorial Society of Bone & Joint Surgery.

  20. Experimental Measurement of the Static Coefficient of Friction at the Ti-Ti Taper Connection in Total Hip Arthroplasty.

    PubMed

    Bitter, T; Khan, I; Marriott, T; Schreurs, B W; Verdonschot, N; Janssen, D

    2016-03-01

    The modular taper junction in total hip replacements has been implicated as a possible source of wear. The finite-element (FE) method can be used to study the wear potential at the taper junction. For such simulations it is important to implement representative contact parameters, in order to achieve accurate results. One of the main parameters in FE simulations is the coefficient of friction. However, in current literature, there is quite a wide spread in coefficient of friction values (0.15 - 0.8), which has a significant effect on the outcome of the FE simulations. Therefore, to obtain more accurate results, one should use a coefficient of friction that is determined for the specific material couple being analyzed. In this study, the static coefficient of friction was determined for two types of titanium-on-titanium stem-adaptor couples, using actual cut-outs of the final implants, to ensure that the coefficient of friction was determined consistently for the actual implant material and surface finish characteristics. Two types of tapers were examined, Biomet type-1 and 12/14, where type-1 has a polished surface finish and the 12/14 is a microgrooved system. We found static coefficients of friction of 0.19 and 0.29 for the 12/14 and type-1 stem-adaptor couples, respectively.

  1. Lower periprosthetic bone loss and good fixation of an ultra-short stem compared to a conventional stem in uncemented total hip arthroplasty

    PubMed Central

    Salemyr, Mats; Muren, Olle; Ahl, Torbjörn; Bodén, Henrik; Eisler, Thomas; Stark, André; Sköldenberg, Olof

    2015-01-01

    Background and purpose — We hypothesized that an ultra-short stem would load the proximal femur in a more physiological way and could therefore reduce the adaptive periprosthetic bone loss known as stress shielding. Patients and methods — 51 patients with primary hip osteoarthritis were randomized to total hip arthroplasty (THA) with either an ultra-short stem or a conventional tapered stem. The primary endpoint was change in periprosthetic bone mineral density (BMD), measured with dual-energy x-ray absorptiometry (DXA), in Gruen zones 1 and 7, two years after surgery. Secondary endpoints were change in periprosthetic BMD in the entire periprosthetic region, i.e. Gruen zones 1 through 7, stem migration measured with radiostereometric analysis (RSA), and function measured with self-administered functional scores. Results — The periprosthetic decrease in BMD was statistically significantly lower with the ultra-short stem. In Gruen zone 1, the mean difference was 18% (95% CI: −27% to −10%). In zone 7, the difference was 5% (CI: −12% to −3%) and for Gruen zones 1–7 the difference was also 5% (CI: −9% to −2%). During the first 6 weeks postoperatively, the ultra-short stems migrated 0.77 mm more on average than the conventional stems. 3 months after surgery, no further migration was seen. The functional scores improved during the study and were similar in the 2 groups. Interpretation — Up to 2 years after total hip arthroplasty, compared to the conventional tapered stem the ultra-short uncemented anatomical stem induced lower periprosthetic bone loss and had equally excellent stem fixation and clinical outcome. PMID:26134386

  2. Comparison for 1030nm DBR-tapered diode lasers with 10W central lobe output power and different grating layouts for wavelength stabilization and lateral spatial mode filtering

    NASA Astrophysics Data System (ADS)

    Müller, André; Zink, Christof; Fricke, Jörg; Bugge, Frank; Erbert, Götz; Sumpf, Bernd; Tränkle, Günther

    2018-02-01

    1030 nm DBR tapered diode lasers with different lateral layouts are presented. The layout comparison includes lasers with straight waveguide and grating, tapered waveguide and straight grating, and straight waveguide and tapered grating. The lasers provide narrowband emission and optical output powers up to 15 W. The highest diffraction-limited central lobe output power of 10.5 W is obtained for lasers with tapered gratings only. Small variations in central lobe output power with RW injection current density also indicate the robustness of that layout. For lasers with tapered waveguides, high RW injection current densities up to 150 A/mm2 have to be applied in order to obtain high central lobe output powers. Lasers with straight waveguide and grating operate best at low RW injection current densities, 50 A/mm2 applied in this study. Using the layout optimizations discussed in this study may help to increase the application potential of DBR tapered diode lasers.

  3. Complex compatible taper and volume estimation systems for red and loblolly pine

    Treesearch

    John C. Byrne; David D. Reed

    1986-01-01

    Five equation systems are described which can be used to estimate upper stem diameter, total individual tree cubic-foot volume, and merchantable cubic-foot volumes to any merchantability imit (expressed in terms of diameter or height), both inside and outside bark. The equations provide consistent results since they are mathematically related and are fit using stem...

  4. Cumulative volume and mass profiles for dominant stems and whole trees tested for northern hardwoods

    Treesearch

    Neil R. Ver Planck; David W. MacFarlane

    2012-01-01

    New models were presented to understand the relationship between the dominant stem and a whole tree using cumulative, whole-tree mass/volume profiles which are compatible with the current bole taper modeling paradigm. New models were developed from intensive, destructive sampling of 32 trees from a temperate hardwood forest in Michigan. The species in the sample were...

  5. Spectrum online-tunable Mach-Zehnder interferometer based on step-like tapers and its refractive index sensing characteristics

    NASA Astrophysics Data System (ADS)

    Zhao, Yong; Chen, Mao-qing; Xia, Feng; Hu, Hai-feng

    2017-11-01

    A novel refractive index (RI) sensor based on an asymmetrical Mach-Zehnder interferometer (MZI) with two different step-like tapers is proposed. The step-like taper is fabricated by fusion splicing two half tapers with an appropriate offset. By further applying offset and discharging to the last fabricated step-like taper of MZI, influence of taper parameters on interference spectrum is investigated using only one device. This simple technique provides an on-line method to sweep parameters of step-like tapers and speeds up the optimization process of interference spectrum, meanwhile. In RI sensing experiment, the sensor has a high sensitivity of -185.79 nm/RIU (refractive index unit) in the RI range of 1.3333-1.3673.

  6. Knee arthrodesis in failed total knee arthroplasty with severe osteolysis and ipsilateral long-stem total hip arthroplasty.

    PubMed

    Sim, Jae Ang; Lee, Beom Koo; Kwak, Ji Hoon; Moon, Sung Hoon

    2009-02-01

    We report a case of knee fusion after a failed total knee arthroplasty (TKA) with severe osteolysis including the epicondyle and ipsilateral total hip arthroplasty (THA) with long Wagner revision stem (Sulzer Orthopedics, Baar, Switzerland). The conventional devices for arthrodesis were unavailable in this case because of the long Wagner revision stem and poor bone stock. A connector was made between the long Wagner revision stem and an intramedullary nail (IM nail; Solco, Seoul, Korea). The custom-made connector was coupled with a femoral stem by cylindrical taper fit with additional cement augmentation and an intramedullary nail by screws. Osseous fusion was achieved without pain or instability.

  7. Electromagnetic field tapering using all-dielectric gradient index materials.

    PubMed

    Yi, Jianjia; Piau, Gérard-Pascal; de Lustrac, André; Burokur, Shah Nawaz

    2016-07-28

    The concept of transformation optics (TO) is applied to control the flow of electromagnetic fields between two sections of different dimensions through a tapering device. The broadband performance of the field taper is numerically and experimentally validated. The taper device presents a graded permittivity profile and is fabricated through three-dimensional (3D) polyjet printing technology using low-cost all-dielectric materials. Calculated and measured near-field mappings are presented in order to validate the proposed taper. A good qualitative agreement is obtained between full-wave simulations and experimental tests. Such all-dielectric taper paves the way to novel types of microwave devices that can be easily fabricated through low-cost additive manufacturing processes.

  8. Fabrication and characterization of tapered graphite/epoxy box beams

    NASA Astrophysics Data System (ADS)

    Yen, S.-C.; Gopal, P.; Dharani, L. R.

    1993-04-01

    Graphite/epoxy (T300/934) prepreg is used to fabricate tapered box beams with a taper angle of 2 deg between the top and bottom walls. The prepreg is cured on a segmented steel core using a hot-press. A screw arrangement is used to apply curing pressure in the horizontal direction, while the platens of the hot-press apply pressure in the vertical direction. The inplane bending stiffness of the beam is determined by 3-point bend test and is found to be in agreement with theory.

  9. The effect of component junction tapering on miniature cryocooler performance

    NASA Astrophysics Data System (ADS)

    Conrad, Ted; Pathak, Mihir G.; Ghiaasiaan, S. Mostafa; Kirkconnell, Carl

    2012-06-01

    Due to their relatively smaller volume and available cooling power, miniature cryocoolers are likely to be more sensitive to hydrodynamic losses than their full scale counterparts. Abrupt changes in diameter between cryocooler components are a possible source of such losses as flow separation and recirculation may occur at these points. Underutilization of regions of the regenerator and heat exchanger porous matrices may also occur due to jetting of fluid into these components. Eliminating such abrupt diameter changes by tapering transitions between cryocooler components may therefore improve system performance. The effects of various tapers applied at component interfaces on the performance of miniature pulse tube cryocoolers were investigated using system-level CFD models. A miniature scale pulse tube cryocooler design whose suitability for cryocooling under ideal conditions has been theoretically demonstrated was used as the basis for these models. Transitions between different combinations of open and porous regions were considered; tapers or chamfers were applied to these component junctions and the performance predictions for the resulting systems were compared to those for a model with sharp component transitions. Visualizations of the predicted flow patterns were also used to determine the effects of the applied tapers on the flow within the pulse tube.

  10. Assessment of a press-fit proximal femoral modular reconstruction implant (PFMR®) at 14.5 years. A 48-case series with a disturbing rate of implant fracture.

    PubMed

    Dumoulin, Q; Sabau, S; Goetzmann, T; Jacquot, A; Sirveaux, F; Mole, D; Roche, O

    2018-05-01

    The PFMR ® proximal femoral modular reconstruction implant (Protek, Sulzer Orthopedics, Switzerland) is a straight modular stem in sanded titanium with press-fit anchorage, intended to achieve spontaneous bone reconstruction following Wagner's principle. The aim of the present study was to analyze long-term clinical and radiological outcome. A single-center retrospective study included 48 PFMR stems implanted in 47 patients between 1998 and 2002. Results in this series were previously reported at 7 years' follow-up. Clinical assessment used PMA and Harris scores. Radiologic assessment focused on stem stability and osseointegration, and bone stock following Le Béguec. Twenty-three patients were seen at a mean 14.5 years' follow-up (13 deceased, 11 lost to follow-up), including 1 with bilateral implants, i.e., 24 stems. PMA and Harris scores, stem stability and osseointegration and bone stock were stable with respect to the 7-year findings. Radiology found 7 stem fractures in the Morse taper, i.e., in 29% of implants. Two of these cases required femoral implant replacement; 5 were asymptomatic. Long-term outcome for PFMR stems was clinically and radiologically satisfactory for the 16 patients free of mechanical complications. The Morse taper fracture rate was high, and higher than reported elsewhere. The usual risk factors for implant fracture were not found in the present series. The modular design of the press-fit revision implant is its weak point; monoblock implants should be used in patients with good life-expectancy. IV (retrospective study). Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  11. The challenge of tree height in Eucalyptus regnans: when xylem tapering overcomes hydraulic resistance.

    PubMed

    Petit, Giai; Pfautsch, Sebastian; Anfodillo, Tommaso; Adams, Mark A

    2010-09-01

    *Recent research suggests that increasing conduit tapering progressively reduces hydraulic constraints caused by tree height. Here, we tested this hypothesis using the tallest hardwood species, Eucalyptus regnans. *Vertical profiles of conduit dimensions and vessel density were measured for three mature trees of height 47, 51 and 63 m. *Mean hydraulic diameter (Dh) increased rapidly from the tree apex to the point of crown insertion, with the greatest degree of tapering yet reported (b > 0.33). Conduit tapering was such that most of the total resistance was found close to the apex (82-93% within the first 1 m of stem) and the path length effect was reduced by a factor of 2000. Vessel density (VD) declined from the apex to the base of each tree, with scaling parameters being similar for all trees (a = 4.6; b = -0.5). *Eucalyptus regnans has evolved a novel xylem design that ensures a high hydraulic efficiency. This feature enables the species to grow quickly to heights of 50-60 m, beyond the maximum height of most other hardwood trees.

  12. Long Term Survivorship of a Severely Notched Femoral Stem after Replacing the Fractured Ceramic head with a Cobalt-Chromium Head

    PubMed Central

    Panagopoulos, Andreas; Tatani, Irini; Megas, Panagiotis

    2016-01-01

    Background: Although ceramic head fracture occurs infrequently today, in the event of a fracture, the resulting revision surgery can prove very challenging, since the ceramic particles lodge into the surrounding soft tissue and can cause rapid implant failure Case Presentation: A case of long term survivorship of a severed notched femoral stem after replacing the fractured femoral head with a cobalt-chromium one is reported in a 40-year old woman with hip dysplasia who underwent an uncomplicated total hip arthroplasty. The incident of ceramic femoral head fracture occurred 14 months postoperatively without reporting any significant trauma. Intraoperative findings at revision were a multifragmented femoral head and a damaged polyethylene insert along with diffuse metallosis and excessive wear of the cone of the stem. Both the stem and the acetabular component were stable. After removal of ceramic fragments, metallotic tissue excision and careful lavage of the joint, the inlay was replaced by a similar one and a cobalt-chromium femoral head was placed to the existing notched taper of the firmly incorporated stem. At the 13th year follow up examination, the patient had no pain, used no walking aids, and had normal activity with no signs of wearing or loosening in the plain x-rays. Conclusion: Despite current recommendations of using ceramic femoral heads in cases of fracture or to revise the severely damaged stems we were able to provide a long term survivorship up to 13 years postoperatively of a cobalt-chromium femoral head applied to a severe damaged stem. PMID:28217203

  13. Long Term Survivorship of a Severely Notched Femoral Stem after Replacing the Fractured Ceramic head with a Cobalt-Chromium Head.

    PubMed

    Panagopoulos, Andreas; Tatani, Irini; Megas, Panagiotis

    2016-01-01

    Although ceramic head fracture occurs infrequently today, in the event of a fracture, the resulting revision surgery can prove very challenging, since the ceramic particles lodge into the surrounding soft tissue and can cause rapid implant failure. A case of long term survivorship of a severed notched femoral stem after replacing the fractured femoral head with a cobalt-chromium one is reported in a 40-year old woman with hip dysplasia who underwent an uncomplicated total hip arthroplasty. The incident of ceramic femoral head fracture occurred 14 months postoperatively without reporting any significant trauma. Intraoperative findings at revision were a multifragmented femoral head and a damaged polyethylene insert along with diffuse metallosis and excessive wear of the cone of the stem. Both the stem and the acetabular component were stable. After removal of ceramic fragments, metallotic tissue excision and careful lavage of the joint, the inlay was replaced by a similar one and a cobalt-chromium femoral head was placed to the existing notched taper of the firmly incorporated stem. At the 13 th year follow up examination, the patient had no pain, used no walking aids, and had normal activity with no signs of wearing or loosening in the plain x-rays. Despite current recommendations of using ceramic femoral heads in cases of fracture or to revise the severely damaged stems we were able to provide a long term survivorship up to 13 years postoperatively of a cobalt-chromium femoral head applied to a severe damaged stem.

  14. Welding-fume-induced transmission loss in tapered optical fibers

    NASA Astrophysics Data System (ADS)

    Yi, Ji-Haeng

    2015-09-01

    This paper presents a method for sensing welding fumes in real time. This method is based on the results of nanoparticle-induced optical-fiber loss experiments that show that the losses are determined by the nanoparticle density and the taper waist. The tapered fiber is obtained by applying heat radiated from hot quartz, and monitoring is done in real time. First, the durability of the tapered fiber during the welding process is proven. Then, the loss is categorized by using the sizes of welding fume particles. The sensitivity to welding fumes increases with increasing size of the particles; consequently, the dimension of the taper waist decreases.

  15. Trunnion Failure of the Recalled Low Friction Ion Treatment Cobalt Chromium Alloy Femoral Head.

    PubMed

    Urish, Kenneth L; Hamlin, Brian R; Plakseychuk, Anton Y; Levison, Timothy J; Higgs, Genymphas B; Kurtz, Steven M; DiGioia, Anthony M

    2017-09-01

    Gross trunnion failure (GTF) is a rare complication in total hip arthroplasty (THA) reported across a range of manufacturers. Specific lots of the Stryker low friction ion treatment (LFIT) anatomic cobalt chromium alloy (CoCr) V40 femoral head were recalled in August 2016. In part, the recall was based out of concerns for disassociation of the femoral head from the stem and GTF. We report on 28 patients (30 implants) with either GTF (n = 18) or head-neck taper corrosion (n = 12) of the LFIT CoCr femoral head and the Accolade titanium-molybdenum-zirconium-iron alloy femoral stems. All these cases were associated with adverse local tissue reactions requiring revision of the THA. In our series, a conservative estimate of the incidence of failure was 4.7% (n = 636 total implanted) at 8.0 ± 1.4 years from the index procedure. Failures were associated with a high-offset 127° femoral stem neck angle and increased neck lengths; 43.3% (13 of 30) of the observed failures included implant sizes outside the voluntary recall (27.8% [5 of 18] of the GTF and 75.0% [8 of 12] of the taper corrosion cases). Serum cobalt and chromium levels were elevated (cobalt: 8.4 ± 7.0 μg/mL; chromium: 3.4 ± 3.3 μ/L; cobalt/chromium ratio: 3.7). The metal artifact reduction sequence magnetic resonance imaging demonstrated large cystic fluid collections typical with adverse local tissue reactions. During revision, a pseudotumor was observed in all cases. Pathology suggested a chronic inflammatory response. Impending GTF could be diagnosed based on aspiration of black synovial fluid and an oblique femoral head as compared with the neck taper on radiographs. In our series of the recalled LFIT CoCr femoral head, the risk of impending GTF or head-neck taper corrosion should be considered as a potential diagnosis in a painful LFIT femoral head and Accolade titanium-molybdenum-zirconium-iron alloy THA with unknown etiology. Almost half of the failures we observed included sizes outside of the voluntary recall. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Hydroxyapatite in total hip arthroplasty. Our experience with a plasma spray porous titanium alloy/hydroxyapatite double-coated cementless stem.

    PubMed

    Castellini, Iacopo; Andreani, Lorenzo; Parchi, Paolo Domenico; Bonicoli, Enrico; Piolanti, Nicola; Risoli, Francesca; Lisanti, Michele

    2016-01-01

    Total hip arthroplasty could fail due to many factors and one of the most common is the aseptic loosening. In order to achieve an effective osseointegration and reduce risk of lossening, the use of cemented implant, contact porous bearing surface and organic coating were developed. Aim of this study was to evaluate clinical and radiological mid-term outcomes of a porous titanium alloy/hydroxyapatite double coating manufactured cementless femoral stem applied with "plasma spray" technique and to demonstrate the possibility to use this stem in different types of femoral canals. Between January 2008 and December 2012, 240 consecutive primary total hip arthroplasties (THAs) were performed using a porous titanium alloy/hydroxyapatite double coating manufactured cementless femoral stem. 182 patients were examined: 136 were females (74.7%) and 46 males (25.2%); average age was 72 years old (ranging from 26 to 92 years old). For each patient, Harris Hip Scores (HHS) and Womac Scores were collected. All X-ray images were analyzed in order to demonstrate stem survival rate and subsidence. Harris Hip Score was good or excellent in 85% of the cases (average 90%) and mean WOMAC score was 97.5 (ranging from 73.4 to 100). No cases of early/late infection or periprosthetic fracture were noticed, with an excellent implant survival rate (100%) in a mean period of 40 months (ranging from 24 and 84 months). 5 cases presented acute implant dislocation, 2 due to wrong cup positioning in a dysplastic acetabulum and 3 after ground level fall. Dorr classification of femoral geometry was uses and the results were: 51 type A bone, 53 type B bone and 78 type C bone. Stem subsidence over 2 mm was considered as a risk factor of future implant loosening and was evidenced in 3 female patients with type C of Dorr classification. No radiolucencies signs around the proximally coated portion of stem or proximal reabsorption were visible during the radiographic follow-up. Concerning the use of porous titanium alloy/hydroxyapatite double coating, this study reported an excellent implant survival rate in a mid-term period with a rate of 1,64% of subsidence in patients with type C of femoral canal but with an optimal HHS and Womac Score results. Regarding this stem, primary stability is guaranteed by trapezoid shape of proximal region and tapering in frontal plane through press-fit technique. Radiological absence of pedestal has been accepted as sign of no excessive stress transmission to distal cortex due to its tapered diaphyseal region. Thanks to the reported data, Authors can consider this double coating a valid choice with an excellent medium-term survival and encouraging subsidence results. Further studies are needed to ensure these results can be replicated.

  17. Polymer optical fiber tapering using hot water

    NASA Astrophysics Data System (ADS)

    Mizuno, Yosuke; Ujihara, Hiroki; Lee, Heeyoung; Hayashi, Neisei; Nakamura, Kentaro

    2017-06-01

    We perform a pilot trial of highly convenient taper fabrication for polymer optical fibers (POFs) using hot water. A ∼380-mm-long POF taper is successfully fabricated, and its ∼150-mm-long waist has a uniform outer diameter of ∼230 µm. The shape is in good agreement with the theoretical prediction. The optical loss dependence on the strain applied to the waist shows an interesting behavior exhibiting three regimes, the origins of which are inferred by microscopic observations. We then discuss the controllability of the taper length.

  18. Microleakage of the prosthetic abutment/implant interface with internal and external connection: in vitro study.

    PubMed

    Larrucea Verdugo, Carlos; Jaramillo Núñez, Guido; Acevedo Avila, Ariel; Larrucea San Martín, Carlo

    2014-09-01

    This study determined the degree of marginal microleakage of the abutment-implant interface on platforms with Morse taper connection and external connection. For this in vitro study, 42 implants, 21 with external connection and 21 with Morse taper connection, were used, immersed in acrylic resin cylinders. Each implant was joined by a prosthetic abutment screw tightened at different degrees, forming the six study groups: (1) External connection, manual tightening (2) External connection, 20 Newton (N) tightening (3) External connection, 30 N tightening (4) Morse taper connection, manual tightening (5) Morse taper connection, 20 N tightening (6) orse taper connection, 30 N tightening. All samples were subjected to load cycling and thermocycling. Then, they were submerged in a solution of 0.2% methylene blue for 24 h. Finally, the microleakage was measured via 20× optical microscopy in each study group, average was obtained, and Mann-Whitney test was applied. Statistically significant differences (P < 0.001) were found between the levels of microleakage presented in the Morse taper connection implants (1.48) and external connection implants (2.8) in all three types of tightening. Microleakage levels decreases when increasing torque is applied to the screws. Morse taper connection implants showed lower levels of microleakage than external connection implants; also, it was observed that microleakage decreases in the way torque increases. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Effects of taper and space settings of telescopic Ce-TZP/A crowns on retentive force and settling.

    PubMed

    Nakagawa, Shusuke; Torii, Katsunori; Tanaka, Masahiro

    2017-03-31

    The aim of this study was to investigate the effect of the taper and space setting of using Ce-TZP/A on retentive force and secondary crown settling. The taper were 2°, 4°, and 6°, and the space settings were 0 and 10 μm. The applied loads were 50 and 100 N. The taper had a significant effect on retentive force and settling at both loads (p<0.05). The space settings did not have a significant effect on retentive force or settling at either load (p<0.05). The taper of the telescopic crowns and the load affected the retentive force and the settling.

  20. Measuring bacterial growth by refractive index tapered fiber optic biosensor.

    PubMed

    Zibaii, Mohammad Ismail; Kazemi, Alireza; Latifi, Hamid; Azar, Mahmoud Karimi; Hosseini, Seyed Masoud; Ghezelaiagh, Mohammad Hossein

    2010-12-02

    A single-mode tapered fiber optic biosensor was utilized for real-time monitoring of the Escherichia coli (E. coli K-12) growth in an aqueous medium. The applied fiber tapers were fabricated using heat-pulling method with waist diameter and length of 6-7μm and 3mm, respectively. The bacteria were immobilized on the tapered surface using Poly-l-Lysine. By providing the proper condition, bacterial population growth on the tapered surface increases the average surface density of the cells and consequently the refractive index (RI) of the tapered region would increase. The adsorption of the cells on the tapered fiber leads to changes in the optical characteristics of the taper. This affects the evanescent field leading to changes in optical throughput. The bacterial growth rate was monitored at room temperature by transmission of a 1558.17nm distributed feedback (DFB) laser through the tapered fiber. At the same condition, after determining the growth rate of E. coli by means of colony counting method, we compared the results with that obtained from the fiber sensor measurements. This novel sensing method, promises new application such as rapid analysis of the presence of bacteria. Copyright © 2010 Elsevier B.V. All rights reserved.

  1. Changes of bone mineral density after cementless total hip arthroplasty with two different stems

    PubMed Central

    Ito, Kouji; Yamamoto, Kengo

    2007-01-01

    Cementless total hip arthroplasty has achieved reliable long-term results since porous coatings were developed, but postoperative changes around the stem remain poorly documented. In this study, changes of the bone mineral density (BMD) were compared between two types of cementless stem. In group B (28 patients with 31 hips), a straight tapered stem with porous plasma spray coating on the proximal 1/4 was used, while group S (24 patients with 26 hips) was given a fluted, tri-slot stem with porous hydroxyapatite coating on the proximal 1/3. In group B, there was an early decrease of BMD, which recovered after 12 months, indicating that stress shielding was minimal. In group S, however, BMD continued to decrease without recovery. The stem shape and radiological findings suggested that the cause of stress shielding in group S was distal fixation. PMID:17225187

  2. Dynamic and thermal analysis of high speed tapered roller bearings under combined loading

    NASA Technical Reports Server (NTRS)

    Crecelius, W. J.; Milke, D. R.

    1973-01-01

    The development of a computer program capable of predicting the thermal and kinetic performance of high-speed tapered roller bearings operating with fluid lubrication under applied axial, radial and moment loading (five degrees of freedom) is detailed. Various methods of applying lubrication can be considered as well as changes in bearing internal geometry which occur as the bearing is brought to operating speeds, loads and temperatures.

  3. Buckling analysis of non-prismatic columns based on modified vibration modes

    NASA Astrophysics Data System (ADS)

    Rahai, A. R.; Kazemi, S.

    2008-10-01

    In this paper, a new procedure is formulated for the buckling analysis of tapered column members. The calculation of the buckling loads was carried out by using modified vibrational mode shape (MVM) and energy method. The change of stiffness within a column is characterized by introducing a tapering index. It is shown that, the changes in the vibrational mode shapes of a tapered column can be represented by considering a linear combination of various modes of uniform-section columns. As a result, by making use of these modified mode shapes (MVM) and applying the principle of stationary total potential energy, the buckling load of tapered columns can be obtained. Several numerical examples on tapered columns demonstrate the accuracy and efficiency of the proposed analytical method.

  4. Threshold temperature optical fibre sensors

    NASA Astrophysics Data System (ADS)

    Stasiewicz, K. A.; Musial, J. E.

    2016-12-01

    This paper presents a new approach to manufacture a threshold temperature sensor based on a biconical optical fibre taper. The presented sensor employs the influence of variable state of concentration of some isotropic materials like wax or paraffin. Application of the above- mentioned materials is an attempt to prove that there is a possibility to obtain a low-cost, repeatable and smart sensor working as an in-line element. Optical fibre taper was obtained from a standard single mode fibre (SMF28®) by using a low pressure gas burner technique. The diameter of the manufactured tapers was 6.0 ± 0.5 μm with the length of elongation equal to 30.50 ± 0.16 mm. The applied technology allowed to produce tapers with the losses of 0.183 ± 0.015 dB. Application of materials with different temperature transition points made it possible to obtain the threshold work at the temperatures connected directly with their conversion temperature. External materials at the temperatures above their melting points do not influence the propagation losses. For each of them two types of the protection area and position of the optical fibre taper were applied.

  5. Fiber optic biosensor fabricated for measuring the growth rate of Escherichia coli K-12 in the aqueous

    NASA Astrophysics Data System (ADS)

    Zibaii, M. I.; Kazemi, A.; Latifi, H.; Karimi Azar, M.; Hosseini, S. M.; Ghezelaiagh, M. H.

    2010-09-01

    A single-mode tapered fiber optic biosensor was utilized for real-time monitoring of the Escherichia coli (E. coli K-12) growth in an aqueous medium. The applied fiber tapers were fabricated using heat-pulling method with waist diameter and length of 6-7μm and 3mm, respectively. The bacteria were immobilized on the tapered surface using Poly-L-Lysine. By providing the proper condition, bacterial population growth on the tapered surface increases the average surface density of the cells and consequently the refractive index (RI) of the tapered region would increase. The adsorption of the cells on the tapered fiber leads to changes in the optical characteristics of the taper. This affects the evanescent field leading to changes in optical throughput. The bacterial growth rate was monitored at room temperature by transmission of a 1558.17nm distributed feedback (DFB) laser through the tapered fiber. At the same condition, after determining the growth rate of E. coli by means of colony counting method, we compared the results with that obtained from the fiber sensor measurements. This novel sensing method, promises new application such as rapid analysis of the presence of bacteria.

  6. Clinical Cold Welding of the Modular Total Hip Arthroplasty Prosthesis.

    PubMed

    Whittaker, Robert K; Zaghloul, Ahmed M; Hothi, Harry S; Siddiqui, Imran A; Blunn, Gordon W; Skinner, John A; Hart, Alister J

    2017-02-01

    A head that is "clinically cold welded" to a stem is one of the commonest reasons for unplanned removal of the stem. It is not clear which hip designs are at greatest risk of clinical cold welding. This was a case-control study of consecutively received hip implant retrievals; we chose the design of hip that had the greatest number of truly cold-welded heads (n = 11). For our controls, we chose retrieved hips of the same design but without cold welding of the head (n = 35). We compared the clinical variables between these 2 groups using nonparametric Mann-Whitney tests to investigate the significance of differences between the cold-welded and non-cold-welded groups. The design that most commonly caused cold welding was a combination of a Ti stem and Ti taper: 11 out of 48 (23%) were truly cold welded. Comparison of the clinical data showed that no individual factor could be used to predict this preoperatively with none of the 4 predictors tested showing any significance: (1) time to revision (P = .687), (2) head size (P = .067), (3) patient age at primary (P = .380), and (4) gender (P = .054). We have shown that clinical cold welding is most prevalent in Ti-Ti combinations of the stem and taper; approximately 25% of cases received at our center were cold welded. Analysis of clinical variables showed that it is not possible to predict which will be cold welded preoperatively. Surgeons should be aware of this potential complication when revising a Ti-Ti stem/head junction. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Coast redwood responses to pruning

    Treesearch

    Kevin L. O' Hara

    2012-01-01

    A large-scale pruning study was established in the winter of 1999 to 2000 at seven different sites on Green Diamond Resource Company forestlands in Humboldt County. The objective of this study was to determine the effects of pruning on increment, epicormic sprouting, stem taper, heartwood formation, and bear damage on these young trees. Pruning treatments varied...

  8. Crown ratio influences allometric scaling in trees

    Treesearch

    Annikki Makela; Harry T. Valentine

    2006-01-01

    Allometric theories suggest that the size and shape of organisms follow universal rules, with a tendency toward quarter-power scaling. In woody plants, however, structure is influenced by branch death and shedding, which leads to decreasing crown ratios, accumulation of heartwood, and stem and branch tapering. This paper examines the impacts on allometric scaling of...

  9. Selecting superior yellow birch trees; a preliminary guide.

    Treesearch

    Knud E. Clausen; Richard M. Godman

    1967-01-01

    Describes procedures to follow and characteristics to consider in selecting superior yellow birch trees. The first selection should be on the basis of tree quality. Characteristics to consider are as follows: for the stem--straightness, roundness, taper grain, self-pruning, and absence of defects; for the crown--apical dominance, branch angle, and branch diameter;...

  10. Transverse Vibration of Tapered Single-Walled Carbon Nanotubes Embedded in Viscoelastic Medium

    NASA Astrophysics Data System (ADS)

    Lei, Y. J.; Zhang, D. P.; Shen, Z. B.

    2017-12-01

    Based on the nonlocal theory, Euler-Bernoulli beam theory and Kelvin viscoelastic foundation model, free transverse vibration is studied for a tapered viscoelastic single-walled carbon nanotube (visco-SWCNT) embedded in a viscoelastic medium. Firstly, the governing equations for vibration analysis are established. And then, we derive the natural frequencies in closed form for SWCNTs with arbitrary boundary conditions by applying transfer function method and perturbation method. Numerical results are also presented to discuss the effects of nonlocal parameter, relaxation time and taper parameter of SWCNTs, and material property parameters of the medium. This study demonstrates that the proposed model is available for vibration analysis of the tapered SWCNTs-viscoelastic medium coupling system.

  11. Comparison of Past, Present, and Future Volume Estimation Methods for Tennessee

    Treesearch

    Stanley J. Zarnoch; Alexander Clark; Ray A. Souter

    2003-01-01

    Forest Inventory and Analysis 1999 survey data for Tennessee were used to compare stem-volume estimates obtained using a previous method, the current method, and newly developed taper models that will be used in the future. Compared to the current method, individual tree volumes were consistently underestimated with the previous method, especially for the hardwoods....

  12. Above- and below-ground characteristics associated with wind toppling in a young Populus plantation.

    Treesearch

    Constance A. Harrington; Dean S. DeBell

    1996-01-01

    Damage from a dormant-season windstorm in a 3-year-old Populus research trial differed among four clones and three spacings and between monoclonal and polyclonal plots. Clonal differences in susceptibility to toppling (or leaning) were associated with both above and below-ground characteristics. Susceptible clones had less taper in the lower stem...

  13. Evaluation of weighted regression and sample size in developing a taper model for loblolly pine

    Treesearch

    Kenneth L. Cormier; Robin M. Reich; Raymond L. Czaplewski; William A. Bechtold

    1992-01-01

    A stem profile model, fit using pseudo-likelihood weighted regression, was used to estimate merchantable volume of loblolly pine (Pinus taeda L.) in the southeast. The weighted regression increased model fit marginally, but did not substantially increase model performance. In all cases, the unweighted regression models performed as well as the...

  14. Fusiform Rust of Southern Pines

    Treesearch

    W. R. Phelps; F. L. Czabator

    1978-01-01

    Fusiform rust, caused by the fungus Cronartium fusiforme Hedg. & Hunt ex Cumm., is distributed in the Southern United States from Maryland to Florida and west to Texas and southern Arkansas. Infections by the fungus, which develops at or near the point of infection, result in tapered, spindle-shaped swells, called galls, on branches and stems of pines. (see photo...

  15. Revision of a Fractured Uncemented Revision Stem Using a Custom Designed Punch and Retrograde Through-Knee Approach

    PubMed Central

    Nasr, P. J.; Keene, G. S.

    2015-01-01

    We report a unique case of a fractured modular cobalt chromium connection taper Revitan (Zimmer, Warsaw, IN) revision prosthesis. Macroscopic examination revealed a fracture at the diaphyseal-metaphyseal junction of this modular component. This report highlights that fractures can still occur with modern modular prostheses. We are not aware of any published failures of the Revitan revision prosthesis. We also describe a unique method of retrieval for a broken well fixed uncemented femoral stem, using a custom designed extraction instrument via a through-knee approach. PMID:25793134

  16. Apically extruded debris with three contemporary Ni-Ti instrumentation systems: an ex vivo comparative study.

    PubMed

    Logani, Ajay; Shah, Naseem

    2008-01-01

    To comparatively evaluate the amount of apically extruded debris when ProTaper hand, ProTaper rotary and ProFile systems were used for the instrumentation of root canals. Thirty minimally curved, mature, human mandibular premolars with single canals were randomly divided into three groups of ten teeth each. Each group was instrumented using one of the three instrumentation systems: ProTaper hand, ProTaper rotary and ProFile. Five milliliters of sterile water were used as an irrigant. Debris extruded was collected in preweighed polyethylene vials and the extruded irrigant was evaporated. The weight of the dry extruded debris was established by comparing the pre- and postinstrumentation weight of polyethylene vials for each group. The Kruskal-Wallis nonparametric test and Mann-Whitney U test were applied to determine if significant differences existed among the groups ( P< 0.05). All instruments tested produced a measurable amount of debris. No statistically significant difference was observed between ProTaper hand and ProFile system ( P > 0.05). Although ProTaper rotary extruded a relatively higher amount of debris, no statistically significant difference was observed between this type and the ProTaper hand instruments ( P > 0.05). The ProTaper rotary extruded significantly more amount of debris compared to the ProFile system ( P< 0.05). Within the limitations of this study, it can be concluded that all instruments tested produced apical extrusion of debris. The ProTaper rotary extruded a significantly higher amount of debris than the ProFile.

  17. Stability of tapered and parallel-walled dental implants: A systematic review and meta-analysis.

    PubMed

    Atieh, Momen A; Alsabeeha, Nabeel; Duncan, Warwick J

    2018-05-15

    Clinical trials have suggested that dental implants with a tapered configuration have improved stability at placement, allowing immediate placement and/or loading. The aim of this systematic review and meta-analysis was to evaluate the implant stability of tapered dental implants compared to standard parallel-walled dental implants. Applying the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) statement, randomized controlled trials (RCTs) were searched for in electronic databases and complemented by hand searching. The risk of bias was assessed using the Cochrane Collaboration's Risk of Bias tool and data were analyzed using statistical software. A total of 1199 studies were identified, of which, five trials were included with 336 dental implants in 303 participants. Overall meta-analysis showed that tapered dental implants had higher implant stability values than parallel-walled dental implants at insertion and 8 weeks but the difference was not statistically significant. Tapered dental implants had significantly less marginal bone loss compared to parallel-walled dental implants. No significant differences in implant failure rate were found between tapered and parallel-walled dental implants. There is limited evidence to demonstrate the effectiveness of tapered dental implants in achieving greater implant stability compared to parallel-walled dental implants. Superior short-term results in maintaining peri-implant marginal bone with tapered dental implants are possible. Further properly designed RCTs are required to endorse the supposed advantages of tapered dental implants in immediate loading protocol and other complex clinical scenarios. © 2018 Wiley Periodicals, Inc.

  18. Stem Profile for Southern Equations for Southern Tree Species

    Treesearch

    Alexander Clark; Ray A. Souter; Bryce E. Schlaegel

    1991-01-01

    Form-class segmented-profile equations for 58 southern tree species and species groups are presented.The profile equations are based on taper data for 13,469 trees sampled in natural stands in many locations across the South.The profile equations predict diameter at any given height, height to give diameter, and volume between two heights.Equation coefficients for use...

  19. Experimental and computational investigation of Morse taper conometric system reliability for the definition of fixed connections between dental implants and prostheses.

    PubMed

    Bressan, Eriberto; Lops, Diego; Tomasi, Cristiano; Ricci, Sara; Stocchero, Michele; Carniel, Emanuele Luigi

    2014-07-01

    Nowadays, dental implantology is a reliable technique for treatment of partially and completely edentulous patients. The achievement of stable dentition is ensured by implant-supported fixed dental prostheses. Morse taper conometric system may provide fixed retention between implants and dental prostheses. The aim of this study was to investigate retentive performance and mechanical strength of a Morse taper conometric system used as implant-supported fixed dental prostheses retention. Experimental and finite element investigations were performed. Experimental tests were achieved on a specific abutment-coping system, accounting for both cemented and non-cemented situations. The results from the experimental activities were processed to identify the mechanical behavior of the coping-abutment interface. Finally, the achieved information was applied to develop reliable finite element models of different abutment-coping systems. The analyses were developed accounting for different geometrical conformations of the abutment-coping system, such as different taper angle. The results showed that activation process, occurred through a suitable insertion force, could provide retentive performances equal to a cemented system without compromising the mechanical functionality of the system. These findings suggest that Morse taper conometrical system can provide a fixed connection between implants and dental prostheses if proper insertion force is applied. Activation process does not compromise the mechanical functionality of the system. © IMechE 2014.

  20. High-efficiency power transfer for silicon-based photonic devices

    NASA Astrophysics Data System (ADS)

    Son, Gyeongho; Yu, Kyoungsik

    2018-02-01

    We demonstrate an efficient coupling of guided light of 1550 nm from a standard single-mode optical fiber to a silicon waveguide using the finite-difference time-domain method and propose a fabrication method of tapered optical fibers for efficient power transfer to silicon-based photonic integrated circuits. Adiabatically-varying fiber core diameters with a small tapering angle can be obtained using the tube etching method with hydrofluoric acid and standard single-mode fibers covered by plastic jackets. The optical power transmission of the fundamental HE11 and TE-like modes between the fiber tapers and the inversely-tapered silicon waveguides was calculated with the finite-difference time-domain method to be more than 99% at a wavelength of 1550 nm. The proposed method for adiabatic fiber tapering can be applied in quantum optics, silicon-based photonic integrated circuits, and nanophotonics. Furthermore, efficient coupling within the telecommunication C-band is a promising approach for quantum networks in the future.

  1. APHiD: Hierarchical Task Placement to Enable a Tapered Fat Tree Topology for Lower Power and Cost in HPC Networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michelogiannakis, George; Ibrahim, Khaled Z.; Shalf, John

    The power and procurement cost of bandwidth in system-wide networks has forced a steady drop in the byte/flop ratio. This trend of computation becoming faster relative to the network is expected to hold. In this paper, we explore how cost-oriented task placement enables reducing the cost of system-wide networks by enabling high performance even on tapered topologies where more bandwidth is provisioned at lower levels. We describe APHiD, an efficient hierarchical placement algorithm that uses new techniques to improve the quality of heuristic solutions and reduces the demand on high-level, expensive bandwidth in hierarchical topologies. We apply APHiD to amore » tapered fat-tree, demonstrating that APHiD maintains application scalability even for severely tapered network configurations. Using simulation, we show that for tapered networks APHiD improves performance by more than 50% over random placement and even 15% in some cases over costlier, state-of-the-art placement algorithms.« less

  2. Modular femoral component for conversion of previous hip surgery in total hip arthroplasty.

    PubMed

    Goldstein, Wayne M; Branson, Jill J

    2005-09-01

    The conversion of previous hip surgery to total hip arthroplasty creates a durable construct that is anatomically accurate. Most femoral components with either cemented or cementless design have a fixed tapered proximal shape. The proximal femoral anatomy is changed due to previous hip surgery for fixation of an intertrochanteric hip fracture, proximal femoral osteotomy, or a fibular allograft for avascular necrosis. The modular S-ROM (DePuy Orthopaedics Inc., Warsaw, Ind) hip stem accommodates these issues and independently prepares the proximal and distal portion of the femur. In preparation and implantation, the S-ROM hip stem creates less hoop stresses on potentially fragile stress risers from screws and thin bone. The S-ROM hip stem also prepares a previously distorted anatomy by milling through cortical bone that can occlude the femoral medullar canals and recreate proper femoral anteversion and reduces the risk of intraoperative or postoperative periprosthetic fracture due to the flexible titanium-slotted stem. The S-ROM femoral stem is recommended for challenging total hip reconstructions.

  3. Stem Cubic-Foot Volume Tables for Tree Species in the Piedmont

    Treesearch

    Alexander Clark; Ray A. Souter

    1996-01-01

    Stemwood cubic-foot volume inside bark tables are presented for 16 species and 8 species groups based on equations used to estimate timber sale volumes on national forests in the Piedmont. Tables are based on form class measurement data for 2,753 trees sampled in the Piedmont and taper data collected across the South. A series of tables is presented for each species...

  4. Stem Cubic-Foot Volume Tables for Tree Species in the Upper Coastal Plain

    Treesearch

    Alexander Clark; Ray A. Souter

    1996-01-01

    Stemwood cubic-foot volume inside bark tables are presented for 11 species and 8 species groups based on equations used to estimate timber sale volumes on national forests in the Upper Coastal Plain. Tables are based on form class measurement data for 521 trees sampled in the Upper Coastal Plain and taper data collected across the South. A series of tables is...

  5. Stem Cubic-Foot Volume Tables for Tree Species in the Appalachian Area

    Treesearch

    Alexander Clark; Ray A. Souter

    1996-01-01

    Stemwood cubic-foot volume inside bark tables are presented for 20 species and 8 species groups based on equations used to estimate timber sale volumes on national forests in the Appalachian Area. Tables are based on form class measurement data for 2,870 trees sampled in the Appalachian Area and taper data collected across the South. A series of tables is presented...

  6. An elastic strip with multiple cracks and applications to tapered specimens

    NASA Technical Reports Server (NTRS)

    Liu, X.-H.; Erdogan, F.

    1985-01-01

    In this paper an infinite elastic strip containing arbitrarily oriented cracks and subjected to uniform tension and a pair of concentrated forces is formulated in terms of a system of singular integral equations. Even though the technique is sufficiently general to solve new multiple crack problem, with the objective of applying the results to tapered specimens, only a certain symmetric crack geometry and loading conditions are considered. The stress intensity factors are calculated for edge cracks in the strip under uniform tension and for a 'compact' and a 'slender' tapered specimen (the latter simulating the double cantilever beam) under concentrated forces or crack surface wedge forces.

  7. The experimental and calculated characteristics of 22 tapered wings

    NASA Technical Reports Server (NTRS)

    Anderson, Raymond F

    1938-01-01

    The experimental and calculated aerodynamic characteristics of 22 tapered wings are compared, using tests made in the variable-density wind tunnel. The wings had aspect ratios from 6 to 12 and taper ratios from 1:6:1 and 5:1. The compared characteristics are the pitching moment, the aerodynamic-center position, the lift-curve slope, the maximum lift coefficient, and the curves of drag. The method of obtaining the calculated values is based on the use of wing theory and experimentally determined airfoil section data. In general, the experimental and calculated characteristics are in sufficiently good agreement that the method may be applied to many problems of airplane design.

  8. A dual modality optical fiber sensor

    NASA Astrophysics Data System (ADS)

    Herrera-Piad, Luis A.; Haus, Joseph W.; Jauregui-Vazquez, Daniel; Lopez-Dieguez, Yanelis; Estudillo-Ayala, Julian M.; Sierra-Hernandez, Juan M.; Hernandez-Garcia, Juan C.; Rojas-Laguna, Roberto

    2018-02-01

    We propose and demonstrate a fibre optic system based on bi-tapered silica fibre that can simultaneously measure strain and fibre curvature. Both modalities on the signal can be extracted with no measurable crosstalk between them. The experimental signal has a pure phase modulation when strain is applied to the tapered fibre optic section of the sensor and the signal shows only intensity modulation when an un-tapered fibre section is bent. High sensitivity is achieved from the experimental results for strain and bending losses and the estimation of measurement errors is 0.2 and 0.1%, respectively. This system offers low-cost, compactness and it can be adapted for structural health monitoring.

  9. Studies of geometrical profiling in fabricated tapered optical fibers using whispering gallery modes spectroscopy

    NASA Astrophysics Data System (ADS)

    Kavungal, Vishnu; Farrell, Gerald; Wu, Qiang; Kumar Mallik, Arun; Semenova, Yuliya

    2018-03-01

    This paper experimentally demonstrates a method for geometrical profiling of asymmetries in fabricated thin microfiber tapers with waist diameters ranging from ∼10 to ∼50 μm with submicron accuracy. The method is based on the analysis of whispering gallery mode resonances excited in cylindrical fiber resonators as a result of evanescent coupling of light propagating through the fiber taper. The submicron accuracy of the proposed method has been verified by SEM studies. The method can be applied as a quality control tool in fabrication of microfiber based devices and sensors or for fine-tuning of microfiber fabrication set-ups.

  10. Adverse Local Tissue Reaction Arising from Corrosion at the Femoral Neck-Body Junction in a Dual-Taper Stem with a Cobalt-Chromium Modular Neck

    PubMed Central

    Cooper, H. John; Urban, Robert M.; Wixson, Richard L.; Meneghini, R. Michael; Jacobs, Joshua J.

    2013-01-01

    Background: Femoral stems with dual-taper modularity were introduced to allow additional options for hip-center restoration independent of femoral fixation in total hip arthroplasty. Despite the increasing availability and use of these femoral stems, concerns exist about potential complications arising from the modular neck-body junction. Methods: This was a multicenter retrospective case series of twelve hips (eleven patients) with adverse local tissue reactions secondary to corrosion at the modular neck-body junction. The cohort included eight women and three men who together had an average age of 60.1 years (range, forty-three to seventy-seven years); all hips were implanted with a titanium-alloy stem and cobalt-chromium-alloy neck. Patients presented with new-onset and increasing pain at a mean of 7.9 months (range, five to thirteen months) following total hip arthroplasty. After serum metal-ion studies and metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) revealed abnormal results, the patients underwent hip revision at a mean of 15.2 months (range, ten to twenty-three months). Tissue specimens were examined by a single histopathologist, and the retrieved implants were studied with use of light and scanning electron microscopy. Results: Serum metal levels demonstrated greater elevation of cobalt (mean, 6.0 ng/mL) than chromium (mean, 0.6 ng/mL) or titanium (mean, 3.4 ng/mL). MRI with use of MARS demonstrated adverse tissue reactions in eight of nine patients in which it was performed. All hips showed large soft-tissue masses and surrounding tissue damage with visible corrosion at the modular femoral neck-body junction. Available histology demonstrated large areas of tissue necrosis in seven of ten cases, while remaining viable capsular tissue showed a dense lymphocytic infiltrate. Microscopic analysis was consistent with fretting and crevice corrosion at the modular neck-body interface. Conclusions: Corrosion at the modular neck-body junction in dual-tapered stems with a modular cobalt-chromium-alloy femoral neck can lead to release of metal ions and debris resulting in local soft-tissue destruction. Adverse local tissue reaction should be considered as a potential cause for new-onset pain in patients with these components, and early revision should be considered given the potentially destructive nature of these reactions. A workup including serologic studies (erythrocyte sedimentation rate and C-reactive protein), serum metal levels, and MARS MRI can be helpful in establishing this diagnosis. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. PMID:23677352

  11. Sinking and fit of abutment of locking taper implant system

    PubMed Central

    Moon, Seung-Jin; Kim, Hee-Jung; Son, Mee-Kyoung

    2009-01-01

    STATEMENT OF PROBLEM Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE In this study, Bicon® Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS 10 Bicon® implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS It was evident, that the amount of abutment sinking in Bicon® Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at 0.45 ± 0.09 mm. CONCLUSION Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location. PMID:21165262

  12. Stem Cubic-Volume Tables for Tree Species in the Deep South Area

    Treesearch

    Alexander Clark; Ray A. Souter

    1996-01-01

    Stemwood cubic-foot volume inside bark tables are presented for 21 species and 8 species groups based on equations used to estimate timber sale volumes on national forests in the Deep South Area. Tables are based on form class measurement data for 2,390 trees sampled in the Deep South Area and taper data collected across the South. A series of tables is presented for...

  13. Stem Cubic-Foot Volume Tables for Tree Species in the Arkansas Area

    Treesearch

    Alexander Clark; Ray A. Souter

    1996-01-01

    Stemwood cubic-foot volume inside bark tables are presented for 9 species and 6 species groups based on equations used to estimate timber sale volumes on national forests in the Arkansas Area. Tables are based on form class measurement data for 1,417 trees sampled in the Arkansas Area and taper data collected across the South. A series of tables is presented for each...

  14. Stem Cubic-Foot Volume Tables for Tree Species in the South

    Treesearch

    Alexander Clark; Ray A. Souter

    1994-01-01

    Stemwood cubic-foot volume tables were presented for 44 species and 10 species groups based on equations used to estimate timber sale volumes on national forests in the South. Tables are based on taper data for 13,469 trees sampled from Virginia to Texas. A series of tables are presented for each species based on diameter at breast height (d.b.h.) in combination with...

  15. Stem Cubic-Foot Volume Tables for Tree Species in the Gulf and Atlantic Coastal Plain

    Treesearch

    Alexander Clark; Ray A. Souter

    1996-01-01

    Stemwood cubic-foot volume inside bark tables are presented for 14 species and 9 species groups based on equations used to estimate timber sale volumes on national forests in the Gulf and Atlantic Coastal Plain. Tables are based on form class measurement data for 2,728 trees sampled in the Gulf and Atlantic Coastal Plain and taper data collected across the South. A...

  16. Stem Cubic-Foot Volume Tabies for Tree Species in the Delta Area

    Treesearch

    Alexander Clark; Ray A. Souter

    1996-01-01

    Stemwood cubic-foot volume inside bark tables are presented for 13 species and 8 species groups based on equations used to estimate timber sale volumes on national forests in the Delta Area. Tables are based on form class measurement data for 990 trees sampled in the Delta Area and taper data collected across the South. A series of tables is presented for each species...

  17. Axial displacement of abutments into implants and implant replicas, with the tapered cone-screw internal connection, as a function of tightening torque.

    PubMed

    Dailey, Bruno; Jordan, Laurence; Blind, Olivier; Tavernier, Bruno

    2009-01-01

    The passive fit of a superstructure on implant abutments is essential to success. One source of error when using a tapered cone-screw internal connection may be the difference between the tightening torque level applied to the abutments by the laboratory technician compared to that applied by the treating clinician. The purpose of this study was to measure the axial displacement of tapered cone-screw abutments into implants and their replicas as a function of the tightening torque level. Twenty tapered cone-screw abutments were selected. Two groups were created: 10 abutments were secured into 10 implants, and 10 abutments were secured into 10 corresponding implant replicas. Each abutment was tightened in increasing increments of 5 Ncm, from 0 Ncm to 45 Ncm, with a torque controller. The length of each sample was measured repeatedly with an Electronic Digital Micrometer. The mean axial displacement for the implant group and the replica group was calculated. The data were analyzed by the Mann-Whitney and Spearman tests. For both groups, there was always an axial displacement of the abutment upon each incremental application of torque. The mean axial displacement values varied between 7 and 12 microm for the implant group and between 6 and 21 microm for the replica group at each 5-Ncm increment. From 0 to 45 Ncm, the total mean axial displacement values were 89 microm for the implant group and 122 microm for the replica group. There was a continuous axial displacement of the abutments into implants and implant replicas when the applied torque was raised from 0 to 45 Ncm. Torque applied above the level recommended by the manufacturer increased the difference in displacement between the two groups.

  18. Water transport through tall trees: A vertically-explicit, analytical model of xylem hydraulic conductance in stems.

    PubMed

    Couvreur, Valentin; Ledder, Glenn; Manzoni, Stefano; Way, Danielle A; Muller, Erik B; Russo, Sabrina E

    2018-05-08

    Trees grow by vertically extending their stems, so accurate stem hydraulic models are fundamental to understanding the hydraulic challenges faced by tall trees. Using a literature survey, we showed that many tree species exhibit continuous vertical variation in hydraulic traits. To examine the effects of this variation on hydraulic function, we developed a spatially-explicit, analytical water transport model for stems. Our model allows Huber ratio, stem-saturated conductivity, pressure at 50% loss of conductivity, leaf area, and transpiration rate to vary continuously along the hydraulic path. Predictions from our model differ from a matric flux potential model parameterized with uniform traits. Analyses show that cavitation is a whole-stem emergent property resulting from nonlinear pressure-conductivity feedbacks that, with gravity, cause impaired water transport to accumulate along the path. Because of the compounding effects of vertical trait variation on hydraulic function, growing proportionally more sapwood and building tapered xylem with height, as well as reducing xylem vulnerability only at branch tips while maintaining transport capacity at the stem base, can compensate for these effects. We therefore conclude that the adaptive significance of vertical variation in stem hydraulic traits is to allow trees to grow tall and tolerate operating near their hydraulic limits. This article is protected by copyright. All rights reserved.

  19. Multitaper Spectral Analysis and Wavelet Denoising Applied to Helioseismic Data

    NASA Technical Reports Server (NTRS)

    Komm, R. W.; Gu, Y.; Hill, F.; Stark, P. B.; Fodor, I. K.

    1999-01-01

    Estimates of solar normal mode frequencies from helioseismic observations can be improved by using Multitaper Spectral Analysis (MTSA) to estimate spectra from the time series, then using wavelet denoising of the log spectra. MTSA leads to a power spectrum estimate with reduced variance and better leakage properties than the conventional periodogram. Under the assumption of stationarity and mild regularity conditions, the log multitaper spectrum has a statistical distribution that is approximately Gaussian, so wavelet denoising is asymptotically an optimal method to reduce the noise in the estimated spectra. We find that a single m-upsilon spectrum benefits greatly from MTSA followed by wavelet denoising, and that wavelet denoising by itself can be used to improve m-averaged spectra. We compare estimates using two different 5-taper estimates (Stepian and sine tapers) and the periodogram estimate, for GONG time series at selected angular degrees l. We compare those three spectra with and without wavelet-denoising, both visually, and in terms of the mode parameters estimated from the pre-processed spectra using the GONG peak-fitting algorithm. The two multitaper estimates give equivalent results. The number of modes fitted well by the GONG algorithm is 20% to 60% larger (depending on l and the temporal frequency) when applied to the multitaper estimates than when applied to the periodogram. The estimated mode parameters (frequency, amplitude and width) are comparable for the three power spectrum estimates, except for modes with very small mode widths (a few frequency bins), where the multitaper spectra broadened the modest compared with the periodogram. We tested the influence of the number of tapers used and found that narrow modes at low n values are broadened to the extent that they can no longer be fit if the number of tapers is too large. For helioseismic time series of this length and temporal resolution, the optimal number of tapers is less than 10.

  20. New type of hip arthroplasty failure related to modular femoral components: breakage at the neck-stem junction.

    PubMed

    Wodecki, P; Sabbah, D; Kermarrec, G; Semaan, I

    2013-10-01

    Total hip replacements (THR) with modular femoral components (stem-neck interface) make it possible to adapt to extramedullary femoral parameters (anteversion, offset, and length) theoretically improving muscle function and stability. Nevertheless, adding a new interface has its disadvantages: reduced mechanical resistance, fretting corrosion and material fatigue fracture. We report the case of a femoral stem fracture of the female part of the component where the modular morse taper of the neck is inserted. An extended trochanteric osteotomy was necessary during revision surgery because the femoral stump could not be grasped for extraction, so that a long stem had to be used. In this case, the patient had the usual risk factors for modular neck failure: he was an active overweight male patient with a long varus neck. This report shows that the female part of the stem of a small femoral component may also be at increased failure risk and should be added to the list of risk factors. To our knowledge, this is the first reported case of this type of failure. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  1. Characterization of Femoral Component Initial Stability and Cortical Strain in a Reduced Stem-Length Design.

    PubMed

    Small, Scott R; Hensley, Sarah E; Cook, Paige L; Stevens, Rebecca A; Rogge, Renee D; Meding, John B; Berend, Michael E

    2017-02-01

    Short-stemmed femoral components facilitate reduced exposure surgical techniques while preserving native bone. A clinically successful stem should ideally reduce risk for stress shielding while maintaining adequate primary stability for biological fixation. We asked (1) how stem-length changes cortical strain distribution in the proximal femur in a fit-and-fill geometry and (2) if short-stemmed components exhibit primary stability on par with clinically successful designs. Cortical strain was assessed via digital image correlation in composite femurs implanted with long, medium, and short metaphyseal fit-and-fill stem designs in a single-leg stance loading model. Strain was compared to a loaded, unimplanted femur. Bone-implant micromotion was then compared with reduced lateral shoulder short stem and short tapered-wedge designs in cyclic axial and torsional testing. Femurs implanted with short-stemmed components exhibited cortical strain response most closely matching that of the intact femur model, theoretically reducing the potential for proximal stress shielding. In micromotion testing, no difference in primary stability was observed as a function of reduced stem length within the same component design. Our findings demonstrate that within this fit-and-fill stem design, reduction in stem length improved proximal cortical strain distribution and maintained axial and torsional stability on par with other stem designs in a composite femur model. Short-stemmed implants may accommodate less invasive surgical techniques while facilitating more physiological femoral loading without sacrificing primary implant stability. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Designing an Optimized Novel Femoral Stem

    PubMed Central

    Babaniamansour, Parto; Ebrahimian-Hosseinabadi, Mehdi; Zargar-Kharazi, Anousheh

    2017-01-01

    Background: After total hip arthroplasty, there would be some problems for the patients. Implant loosening is one of the significant problems which results in thigh pain and even revision surgery. Difference between Young's modulus of bone-metal is the cause of stress shielding, atrophy, and subsequent implant loosening. Materials and Methods: In this paper, femoral stem stiffness is reduced by novel biomechanical and biomaterial design which includes using proper design parameters, coating it with porous surface, and modeling the sketch by the software. Parametric design of femoral stem is done on the basis of clinical reports. Results: Optimized model for femoral stem is proposed. Curved tapered stem with trapezoidal cross-section and particular neck and offset is designed. Fully porous surface is suggested. Moreover, Designed femoral stem analysis showed the Ti6Al4V stem which is covered with layer of 1.5 mm in thickness and 50% of porosity is as stiff as 77 GPa that is 30% less than the stem without any porosity. Porous surface of designed stem makes it fix biologically; thus, prosthesis loosening probability decreases. Conclusion: By optimizing femoral stem geometry (size and shape) and also making a porous surface, which had an intermediate stiffness of bone and implant, a more efficient hip joint prosthesis with more durability fixation was achieved due to better stress transmission from implant to the bone. PMID:28840118

  3. Examination of tapered plastic multimode fiber-based sensor performance with silver coating for different concentrations of calcium hypochlorite by soft computing methodologies--a comparative study.

    PubMed

    Zakaria, Rozalina; Sheng, Ong Yong; Wern, Kam; Shamshirband, Shahaboddin; Wahab, Ainuddin Wahid Abdul; Petković, Dalibor; Saboohi, Hadi

    2014-05-01

    A soft methodology study has been applied on tapered plastic multimode sensors. This study basically used tapered plastic multimode fiber [polymethyl methacrylate (PMMA)] optics as a sensor. The tapered PMMA fiber was fabricated using an etching method involving deionized water and acetone to achieve a waist diameter and length of 0.45 and 10 mm, respectively. In addition, a tapered PMMA probe, which was coated by silver film, was fabricated and demonstrated using a calcium hypochlorite (G70) solution. The working mechanism of such a device is based on the observation increment in the transmission of the sensor that is immersed in solutions at high concentrations. As the concentration was varied from 0 to 6 ppm, the output voltage of the sensor increased linearly. The silver film coating increased the sensitivity of the proposed sensor because of the effective cladding refractive index, which increases with the coating and thus allows more light to be transmitted from the tapered fiber. In this study, the polynomial and radial basis function (RBF) were applied as the kernel function of the support vector regression (SVR) to estimate and predict the output voltage response of the sensors with and without silver film according to experimental tests. Instead of minimizing the observed training error, SVR_poly and SVR_rbf were used in an attempt to minimize the generalization error bound so as to achieve generalized performance. An adaptive neuro-fuzzy interference system (ANFIS) approach was also investigated for comparison. The experimental results showed that improvements in the predictive accuracy and capacity for generalization can be achieved by the SVR_poly approach in comparison to the SVR_rbf methodology. The same testing errors were found for the SVR_poly approach and the ANFIS approach.

  4. Ten-Year Cross-Sectional Study of Mechanically Assisted Crevice Corrosion in 1352 Consecutive Patients With Metal-on-Polyethylene Total Hip Arthroplasty.

    PubMed

    Hussey, Daniel K; McGrory, Brian J

    2017-08-01

    Mechanically assisted crevice corrosion (MACC) in metal-on-polyethylene total hip arthroplasty (THA) is of concern, but its prevalence, etiology, and natural history are incompletely understood. From January 2003 to December 2012, 1352 consecutive THA surgeries using a titanium stem, cobalt-chromium alloy femoral head, and highly cross-linked polyethylene liner from a single manufacturer were performed. Patients were followed at 1-year and 5-year intervals for surveillance, but also seen earlier if they had symptoms. Any patient with osteolysis >1 cm (n = 3) or unexplained pain (n = 85) underwent examination, radiographs, complete blood count, erythrocyte sedimentation rate, and C-reactive protein, as well as tests for serum cobalt and chromium levels. Symptomatic MACC was present in 43 of 1352 patients (3.2%). Prevalence of MACC by year of implant ranged from 0% (0 of 61, 2003; 0 of 138, 2005) to 10.5% (17 of 162; 2009). The M/L Taper stem had a greater prevalence (4.9%) of MACC than all other Zimmer (Zimmer, Inc, Warsaw, IN) 12/14 trunnion stem types combined (1.2%; P < .001). Twenty-seven of 43 (62.8%) patients have undergone revision surgery, and 16 of 43 (37.2%) patients have opted for ongoing surveillance. Comparing symptomatic THA patients with and without MACC, no demographic, clinical, or radiographic differences were found. MACC was significantly more common in 0 length femoral heads (compared with both -3.5 mm and +3.5 mm heads). The prevalence of MACC in metal-on-polyethylene hips is higher in this cross-sectional study than previously reported. A significantly higher prevalence was found in patients with M/L Taper style stem and THA performed both in 2009 and also between 2009 and 2012 with this manufacturer. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Rotational flow in tapered slab rocket motors

    NASA Astrophysics Data System (ADS)

    Saad, Tony; Sams, Oliver C.; Majdalani, Joseph

    2006-10-01

    Internal flow modeling is a requisite for obtaining critical parameters in the design and fabrication of modern solid rocket motors. In this work, the analytical formulation of internal flows particular to motors with tapered sidewalls is pursued. The analysis employs the vorticity-streamfunction approach to treat this problem assuming steady, incompressible, inviscid, and nonreactive flow conditions. The resulting solution is rotational following the analyses presented by Culick for a cylindrical motor. In an extension to Culick's work, Clayton has recently managed to incorporate the effect of tapered walls. Here, an approach similar to that of Clayton is applied to a slab motor in which the chamber is modeled as a rectangular channel with tapered sidewalls. The solutions are shown to be reducible, at leading order, to Taylor's inviscid profile in a porous channel. The analysis also captures the generation of vorticity at the surface of the propellant and its transport along the streamlines. It is from the axial pressure gradient that the proper form of the vorticity is ascertained. Regular perturbations are then used to solve the vorticity equation that prescribes the mean flow motion. Subsequently, numerical simulations via a finite volume solver are carried out to gain further confidence in the analytical approximations. In illustrating the effects of the taper on flow conditions, comparisons of total pressure and velocity profiles in tapered and nontapered chambers are entertained. Finally, a comparison with the axisymmetric flow analog is presented.

  6. Leakage of the fundamental mode in photonic crystal fiber tapers.

    PubMed

    Nguyen, Hong C; Kuhlmey, Boris T; Steel, Michael J; Smith, Cameron L; Mägi, Eric C; McPhedran, Ross C; Eggleton, Benjamin J

    2005-05-15

    We report detailed measurements of the optical properties of tapered photonic crystal fibers (PCFs). We observe a striking long-wavelength loss as the fiber diameter is reduced, despite the minimal airhole collapse along the taper. We associate this loss with a transition of the fundamental core mode as the fiber dimensions contract: At wavelengths shorter than this transition wavelength, the core mode is strongly confined in the fiber microstructure, whereas at longer wavelengths the mode expands beyond the microstructure and couples out to higher-order modes. These experimental results are discussed in the context of the so-called fundamental mode cutoff described by Kuhlmey et al. [Opt. Express 10, 1285 (2002)], which apply to PCFs with a finite microstructure.

  7. Fully automated lobe-based airway taper index calculation in a low dose MDCT CF study over 4 time-points

    NASA Astrophysics Data System (ADS)

    Weinheimer, Oliver; Wielpütz, Mark O.; Konietzke, Philip; Heussel, Claus P.; Kauczor, Hans-Ulrich; Brochhausen, Christoph; Hollemann, David; Savage, Dasha; Galbán, Craig J.; Robinson, Terry E.

    2017-02-01

    Cystic Fibrosis (CF) results in severe bronchiectasis in nearly all cases. Bronchiectasis is a disease where parts of the airways are permanently dilated. The development and the progression of bronchiectasis is not evenly distributed over the entire lungs - rather, individual functional units are affected differently. We developed a fully automated method for the precise calculation of lobe-based airway taper indices. To calculate taper indices, some preparatory algorithms are needed. The airway tree is segmented, skeletonized and transformed to a rooted acyclic graph. This graph is used to label the airways. Then a modified version of the previously validated integral based method (IBM) for airway geometry determination is utilized. The rooted graph, the airway lumen and wall information are then used to calculate the airway taper indices. Using a computer-generated phantom simulating 10 cross sections of airways we present results showing a high accuracy of the modified IBM. The new taper index calculation method was applied to 144 volumetric inspiratory low-dose MDCT scans. The scans were acquired from 36 children with mild CF at 4 time-points (baseline, 3 month, 1 year, 2 years). We found a moderate correlation with the visual lobar Brody bronchiectasis scores by three raters (r2 = 0.36, p < .0001). The taper index has the potential to be a precise imaging biomarker but further improvements are needed. In combination with other imaging biomarkers, taper index calculation can be an important tool for monitoring the progression and the individual treatment of patients with bronchiectasis.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsutani, Takaomi; Taya, Masaki; Ikuta, Takashi

    A parallel image detection system using an annular pupil for electron optics were developed to realize an increase in the depth of focus, aberration-free imaging and separation of amplitude and phase images under scanning transmission electron microscopy (STEM). Apertures for annular pupils able to suppress high-energy electron scattering were developed using a focused ion beam (FIB) technique. The annular apertures were designed with outer diameter of oe 40 {mu}m and inner diameter of oe32 {mu}m. A taper angle varying from 20 deg. to 1 deg. was applied to the slits of the annular apertures to suppress the influence of high-energymore » electron scattering. Each azimuth angle image on scintillator was detected by a multi-anode photomultiplier tube assembly through 40 optical fibers bundled in a ring shape. To focus the image appearing on the scintillator on optical fibers, an optical lens relay system attached with CCD camera was developed. The system enables the taking of 40 images simultaneously from different scattered directions.« less

  9. Within crown variation in the relationship between foliage biomass and sapwood area in jack pine.

    PubMed

    Schneider, Robert; Berninger, Frank; Ung, Chhun-Huor; Mäkelä, Annikki; Swift, D Edwin; Zhang, S Y

    2011-01-01

    The relationship between sapwood area and foliage biomass is the basis for a lot of research on eco-phyisology. In this paper, foliage biomass change between two consecutive whorls is studied, using different variations in the pipe model theory. Linear and non-linear mixed-effect models relating foliage differences to sapwood area increments were tested to take into account whorl location, with the best fit statistics supporting the non-linear formulation. The estimated value of the exponent is 0.5130, which is significantly different from 1, the expected value given by the pipe model theory. When applied to crown stem sapwood taper, the model indicates that foliage biomass distribution influences the foliage biomass to sapwood area at crown base ratio. This result is interpreted as being the consequence of differences in the turnover rates of sapwood and foliage. More importantly, the model explains previously reported trends in jack pine sapwood area at crown base to tree foliage biomass ratio.

  10. Applying a tapered electrode on a porous ceramic support tube by masking a band inside the tube and drawing in electrode material from the outside of the tube by suction

    DOEpatents

    Vasilow, T.R.; Zymboly, G.E.

    1991-12-17

    An electrode is deposited on a support by providing a porous ceramic support tube having an open end and closed end; masking at least one circumferential interior band inside the tube; evacuating air from the tube by an evacuation system, to provide a permeability gradient between the masked part and unmasked part of the tube; applying a liquid dispersion of solid electrode particles to the outside surface of the support tube, where liquid flows through the wall, forming a uniform coating over the unmasked support part and a tapered coating over the masked part. 2 figures.

  11. On wings and keels (2)

    NASA Astrophysics Data System (ADS)

    Slooff, J. W.

    1985-05-01

    The physical mechanisms governing the hydrodynamics of sailing yacht keels and the parameters that, through these mechanisms, determine keel performance are discussed. It is concluded that due to the presence of the free water surface optimum keel shapes differ from optimum shapes for aircraft wings. Utilizing computational fluid dynamics analysis and optimization it is found that the performance of conventional keels can be improved significantly by reducing taper or even applying inverse taper (upside-down keel) and that decisive improvements in performance can be realized through keels with winglets.

  12. A Rotational and Axial Motion System Load Frame Insert for In Situ High Energy X-Ray Studies (Postprint)

    DTIC Science & Technology

    2015-09-08

    N) without sample slippage. Equally critical is the applied tightening torque of the tapered compression nut in order to provide the necessary...preloaded linear ball spline which enables torque to be transferred to both the upper and lower rotation stages despite the fact that their vertical...interference fit, where a collet and tapered compression nut act to impart increasing pressure on the grip region of the specimen as increasing torque is

  13. Development and First Results of the Width-Tapered Beam Method for Adhesion Testing of Photovoltaic Material Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bosco, Nick; Tracy, Jared; Dauskardt, Reinhold

    2016-11-21

    A fracture mechanics based approach for quantifying adhesion at every interface within the PV module laminate is presented. The common requirements of monitoring crack length and specimen compliance are circumvented through development of a width-tapered cantilever beam method. This technique may be applied at both the module and coupon level to yield a similar, quantitative, measurement. Details of module and sample preparation are described and first results on field-exposed modules deployed for over 27 years presented.

  14. Influence of Different Screw Torque Levels on the Biomechanical Behavior of Tapered Prosthetic Abutments.

    PubMed

    Herbst, Paulo Eduardo; de Carvalho, Eduardo Bortolas; Salatti, Rafael C; Valgas, Laiz; Tiossi, Rodrigo

    To study the force used for tightening tapered one-piece prosthetic abutments and their influence on the removal torque value and stress level of the prosthetic abutment after cyclic loading. Fourteen implants and prosthetic abutments were divided into two groups (n = 7): G1, 20 Ncm; and G2, 32 Ncm (manufacturer recommended). A 20-mm T-shaped horizontal bar was adapted to the abutments. A 12-Hz cyclic loading was applied to the specimens in an electrodynamic testing system with the maximum number of cycles set to 10 6 . Specimens were inclined by 15 degrees from the vertical axis, and a 5-mm off-center vertical load was applied to generate a combination of bending and torquing moments on the tapered connections. Progressive loads (from 164.85 to 362.85 N) were applied when the previous sample survived 10 6 cycles. The paired t test compared the screw removal torque with the initial tightening torque for each group (α = .05). A finite element analysis (FEA) of the mechanical testing analyzed the regions of stress concentration. No specimens failed after 10 6 cyclic loadings. The mean screw removal torque for both groups was similar to the initial abutment torque value applied for each group (G1, 20.36 ± 8.73 Ncm; and G2, 35.61 ± 6.99 Ncm) (P > .05). FEA showed similar stress behavior for both groups in the study despite the different simulated screw preloads (G1: 200 N; G2: 320 N). The coronal region of the implant body presented the highest strain values in both groups. Tightening tapered one-piece prosthetic abutments at 20 and 32 Ncm maintains a stable connection after cyclic loading. The stresses generated by the different tightening forces during cyclic loading are highest at the coronal level of the connection.

  15. Label-Free Detection of Cancer Biomarkers Using an In-Line Taper Fiber-Optic Interferometer and a Fiber Bragg Grating

    PubMed Central

    Sun, Dandan; Wang, Guanjun

    2017-01-01

    A compact and label-free optical fiber sensor based on a taper interferometer cascaded with a fiber Bragg grating (FBG) is proposed and experimentally demonstrated for detection of a breast cancer biomarker (HER2). The tapered fiber-optic interferometer is extremely sensitive to the ambient refractive index (RI). In addition, being insensitive to the RI variation, the FBG can be applied as a temperature thermometer due to its independent response to the temperature. Surface functionalization to the sensor is carried out to achieve specific targeting of the unlabeled biomarkers. The result shows that the proposed sensor presents a low limit-of-detection (LOD) of 2 ng/mL, enabling its potentials of application in early diagnosis on the breast cancer. PMID:29113127

  16. Narrowband spectral filter based on biconical tapered fiber

    NASA Astrophysics Data System (ADS)

    Celaschi, Sergio; Malheiros-Silveira, Gilliard N.

    2018-02-01

    The ease of fabrication and compactness of devices based on tapered optical fibers contribute to its potential using in several applications ranging from telecommunication components to sensing devices. In this work, we proposed, fabricated, and characterized a spectral filter made of biconical taper from a coaxial optical fiber. This filter is defined by adiabatically tapering a depressed-cladding fiber. The adiabatic taper profile obtained during fabrication prevents the interference of other modes than HE11 and HE12 ones, which play the main role for the beating phenomenon and the filter response. The evolution of the fiber shapes during the pulling was modeled by two coupled partial differential equations, which relate the normalized cross-section area, and the axial velocity of the fiber elongation. These equations govern the mass and axial momentum conservation. The numerical results of the filter characteristics are in good accordance with the experimental ones. The filter was packaged in order to let it ready for using in optical communication bands. The characteristics are: free spectral range (FSR) of 6.19 nm, insertion loss bellow 0.5 dB, and isolation > 20 dB at C-band. Its transmission spectrum extends from 1200 to 1600 nm where the optical fiber core supports monomode transmission. Such characteristics may also be interesting to be applied in sensing applications. We show preliminary numerical results assuming a biconic taper embedded into a dielectric media, showing promising results for electro-optic sensing applications.

  17. Tapered optical fiber tip probes based on focused ion beam-milled Fabry-Perot microcavities

    NASA Astrophysics Data System (ADS)

    André, Ricardo M.; Warren-Smith, Stephen C.; Becker, Martin; Dellith, Jan; Rothhardt, Manfred; Zibaii, M. I.; Latifi, H.; Marques, Manuel B.; Bartelt, Hartmut; Frazão, Orlando

    2016-09-01

    Focused ion beam technology is combined with dynamic chemical etching to create microcavities in tapered optical fiber tips, resulting in fiber probes for temperature and refractive index sensing. Dynamic chemical etching uses hydrofluoric acid and a syringe pump to etch standard optical fibers into cone structures called tapered fiber tips where the length, shape, and cone angle can be precisely controlled. On these tips, focused ion beam is used to mill several different types of Fabry-Perot microcavities. Two main cavity types are initially compared and then combined to form a third, complex cavity structure. In the first case, a gap is milled on the tapered fiber tip which allows the external medium to penetrate the light guiding region and thus presents sensitivity to external refractive index changes. In the second, two slots that function as mirrors are milled on the tip creating a silica cavity that is only sensitive to temperature changes. Finally, both cavities are combined on a single tapered fiber tip, resulting in a multi-cavity structure capable of discriminating between temperature and refractive index variations. This dual characterization is performed with the aid of a fast Fourier transform method to separate the contributions of each cavity and thus of temperature and refractive index. Ultimately, a tapered optical fiber tip probe with sub-standard dimensions containing a multi-cavity structure is projected, fabricated, characterized and applied as a sensing element for simultaneous temperature and refractive index discrimination.

  18. Simulation and experimental validation of droplet dynamics in microchannels of PEM fuel cells

    NASA Astrophysics Data System (ADS)

    Ashrafi, Moosa; Shams, Mehrzad; Bozorgnezhad, Ali; Ahmadi, Goodarz

    2016-12-01

    In this study, dynamics of droplets in the channels of proton exchange membrane fuel cells with straight and serpentine flow-fields was investigated. Tapered and filleted channels were suggested for the straight and serpentine flow-fields respectively in order to improve water removal in channels. Surface tension and wall adhesion forces were applied by using the volume of fluid method. The hydrophilic walls and hydrophobic gas diffusion layer were considered. The mechanism of droplets movement with different diameters was studied by using the Weber and capillary numbers in simple and tapered straight channels. It was illustrated that the flooding was reduced in tapered channel due to increase of water removal rate, and available reaction sites improved subsequently. In addition, film flow was formed in the tapered channel more than the simple channel, so pressure fluctuation was decreased in the tapered channel. Moreover, the water coverage ratio of hydrophilic tapered surface was more than the simple channel, which enhanced water removal from the channel. The filleted serpentine channel was introduced to improve water removal from the simple serpentine channel. It was shown by observation of the unsteady and time-averaged two-phase pressure drop that in the filleted serpentine channels, the two-phase pressure drop was far less than the simple serpentine channel, and also the accumulation of water droplets in the elbows was less leading to lower pressure fluctuation. The numerical simulation results were validated by experiments.

  19. Efficacy of ProTaper and Mtwo Retreatment Files in Removal of Gutta-percha and GuttaFlow from Root Canals

    PubMed Central

    Khedmat, Sedigheh; Azari, Abbas; Shamshiri, Ahmad Reza; Fadae, Mehdi; Bashizadeh Fakhar, Hoorieh

    2016-01-01

    Introduction: The aim of this in vitro study was to compare the efficacy of ProTaper retreatment (ProTaper R) and Mtwo retreatment (Mtwo R) files in removing gutta-percha and GuttaFlow from endodontically treated straight root canals. Methods and Materials: The root canals of 60 human mandibular single-rooted premolars were prepared and randomly divided into two groups (n=30). In groups A and B the root canals were obturated using lateral condensation of gutta-percha plus AH 26 and GuttaFlow, respectively. The canal orifices were temporarily sealed and the roots were incubated for 3 months at 37ºC and 100% humidity. Primary cone-beam computed tomography (CBCT) images were taken after incubation period. The specimens in each group were randomly divided into two subgroups (n=15). ProTaper R files (D1, D2, and D3) were used in groups A1 and B1 while Mtwo R files (25/0.05 and 15/0.05) were used in groups A2 and B2. The time required to extirpate the root filling was also recorded. After retreatment, another CBCT scan was taken at the same position. The volume of remaining filling materials inside the canals was calculated before and after retreatment. The data was analyzed using the two-way ANOVA and independent t-test. Results: The remaining filling materials in the canals treated with ProTaper were less than Mtwo. The remaining volume of GuttaFlow was less than gutta-percha regardless of the system applied. Mtwo R files removed root fillings faster than ProTaper R. Conclusion: ProTaper R removed filling material more efficiently compared to Mtwo R which required less time to remove root filling material. PMID:27471528

  20. Evaluation of the incidence of microcracks caused by Mtwo and ProTaper Next rotary file systems versus the self-adjusting file: A scanning electron microscopic study

    PubMed Central

    Saha, Suparna Ganguly; Vijaywargiya, Neelam; Saxena, Divya; Saha, Mainak Kanti; Bharadwaj, Anuj; Dubey, Sandeep

    2017-01-01

    Introduction: To evaluate the incidence of microcrack formation canal preparation with two rotary nickel–titanium systems Mtwo and ProTaper Next along with the self-adjusting file system. Materials and Methods: One hundred and twenty mandibular premolar teeth were selected. Standardized access cavities were prepared and the canals were manually prepared up to size 20 after coronal preflaring. The teeth were divided into three experimental groups and one control group (n = 30). Group 1: The canals were prepared using Mtwo rotary files. Group 2: The canals were prepared with ProTaper Next files. Group 3: The canals were prepared with self-adjusting files. Group 4: The canals were unprepared and used as a control. The roots were sectioned horizontally 3, 6, and 9 mm from the apex and examined under a scanning electron microscope to check for the presence of microcracks. The Pearson's Chi-square test was applied. Results: The highest incidence of microcracks were associated with the ProTaper Next group, 80% (P = 0.00), followed by the Mtwo group, 70% (P = 0.000), and the least number of microcracks was noted in the self-adjusting file group, 10% (P = 0.068). No significant difference was found between the ProTaper Next and Mtwo groups (P = 0.368) while a significant difference was observed between the ProTaper Next and self-adjusting file groups (P = 0.000) as well as the Mtwo and self-adjusting file groups (P = 0.000). Conclusion: All nickel–titanium rotary instrument systems were associated with microcracks. However, the self-adjusting file system had significantly fewer microcracks when compared with the Mtwo and ProTaper Next. PMID:29386786

  1. Evaluation of the incidence of microcracks caused by Mtwo and ProTaper Next rotary file systems versus the self-adjusting file: A scanning electron microscopic study.

    PubMed

    Saha, Suparna Ganguly; Vijaywargiya, Neelam; Saxena, Divya; Saha, Mainak Kanti; Bharadwaj, Anuj; Dubey, Sandeep

    2017-01-01

    To evaluate the incidence of microcrack formation canal preparation with two rotary nickel-titanium systems Mtwo and ProTaper Next along with the self-adjusting file system. One hundred and twenty mandibular premolar teeth were selected. Standardized access cavities were prepared and the canals were manually prepared up to size 20 after coronal preflaring. The teeth were divided into three experimental groups and one control group ( n = 30). Group 1: The canals were prepared using Mtwo rotary files. Group 2: The canals were prepared with ProTaper Next files. Group 3: The canals were prepared with self-adjusting files. Group 4: The canals were unprepared and used as a control. The roots were sectioned horizontally 3, 6, and 9 mm from the apex and examined under a scanning electron microscope to check for the presence of microcracks. The Pearson's Chi-square test was applied. The highest incidence of microcracks were associated with the ProTaper Next group, 80% ( P = 0.00), followed by the Mtwo group, 70% ( P = 0.000), and the least number of microcracks was noted in the self-adjusting file group, 10% ( P = 0.068). No significant difference was found between the ProTaper Next and Mtwo groups ( P = 0.368) while a significant difference was observed between the ProTaper Next and self-adjusting file groups ( P = 0.000) as well as the Mtwo and self-adjusting file groups ( P = 0.000). All nickel-titanium rotary instrument systems were associated with microcracks. However, the self-adjusting file system had significantly fewer microcracks when compared with the Mtwo and ProTaper Next.

  2. Connecting Molecular Dynamics Simulations and Fluids Density Functional Theory of Block Copolymers

    NASA Astrophysics Data System (ADS)

    Hall, Lisa

    Increased understanding and precise control over the nanoscale structure and dynamics of microphase separated block copolymers would advance development of mechanically robust but conductive materials for battery electrolytes, among other applications. Both coarse-grained molecular dynamics (MD) simulations and fluids (classical) density functional theory (fDFT) can capture the microphase separation of block copolymers, using similar monomer-based chain models and including local packing effects. Equilibrium free energies of various microphases are readily accessible from fDFT, which allows us to efficiently determine the equilibrium nanostructure over a large parameter space. Meanwhile, MD allows us to visualize specific polymer conformations in 3D over time and to calculate dynamic properties. The fDFT density profiles are used to initialize the MD simulations; this ensures the MD proceeds in the appropriate microphase separated state rather than in a metastable structure (useful especially for nonlamellar structures). The simulations equilibrate more quickly than simulations initialized with a random state, which is significant especially for long chains. We apply these methods to study the interfacial behavior and microphase separated structure of diblock and tapered block copolymers. Tapered copolymers consist of pure A and B monomer blocks on the ends separated by a tapered region that smoothly varies from A to B (or from B to A for an inverse taper). Intuitively, tapering increases the segregation strength required for the material to microphase separate and increases the width of the interfacial region. Increasing normal taper length yields a lower domain spacing and increased polymer mobility, while larger inverse tapers correspond to even lower domain spacing but decreased mobility. Thus the changes in dynamics with tapering cannot be explained by mapping to a diblock system at an adjusted effective segregation strength. This material is based upon work supported by the National Science Foundation under Grant 1454343 and the Department of Energy under Grant DE-SC0014209.

  3. Influence of nickel-titanium rotary systems with varying tapers on the biomechanical behaviour of maxillary first premolars under occlusal forces: a finite element analysis study.

    PubMed

    Askerbeyli Örs, S; Serper, A

    2018-05-01

    To evaluate the effect of three nickel-titanium (Ni-Ti) rotary systems with varying tapers on stress distribution and to analyse potential fracture patterns as well as the volume of fracture-susceptible regions in two-rooted maxillary premolars. The root canals of three single-rooted premolars were prepared with either HeroShaper (Micro-Mega, Besançon, France) to (size 30, .04 taper), Revo-S (Micro-Mega) to AS30 (size 30, .06 taper) or ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland) to F3 (size 30, .09 taper) Ni-Ti files. The three root canals were scanned using micro-computed tomography (μCT) (Skyscan 1174, Skyscan, Kontich, Belgium) and modelled according to the μCT data. An intact tooth model with a root length of 16 mm was also constructed based on μCT images of an extracted maxillary premolar with two roots. New models were constructed by replacing both of the original canals of the intact two-rooted premolar model with the modelled canals prepared with the HeroShaper, Revo-S or ProTaper Universal system. Occlusal forces of 200 N were applied in oblique and vertical directions. Finite element analysis was performed using Abaqus FEA software (Abaqus 6.14, ABAQUS Inc., Providence, RI, USA). Upon the application of oblique occlusal forces, the palatal external cervical root surface and the bifurcation (palatal side of the buccal root) in tooth models experienced the highest maximum principal (Pmax) stresses. The application of vertical forces resulted in minor Pmax stress values. Models prepared using the ProTaper system exhibited the highest Pmax stress values. The intact models exhibited the lowest Pmax stress values followed by the models prepared with the HeroShaper system. The differences in Pmax stress values amongst the different groups of models were mathematically minimal under normal occlusal forces. Rotary systems with varying tapers might predispose the root fracture on the palatal side of the buccal root and cervical palatal root surface in two-rooted premolars. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  4. Mode Transition of RNA Trap by Electric and Hydraulic Force Field in Microfluidic Taper Shape Channel

    NASA Astrophysics Data System (ADS)

    Takamura, Yuzuru; Ueno, Kunimitsu; Nagasaka, Wako; Tomizawa, Yuichi; Tamiya, Eiichi

    2007-03-01

    We have discovered a phenomenon of accumulation of DNA near the constricted position of a microfluidic chip with taper shaped channel when both hydro pressure and electric field are applied in opposite directions. However, RNA has not been able to trap so far, unlike huge and uniformly double stranded DNA molecules, RNAs are smaller in size and single stranded with complicated conformation like blocks in lysed cell solution. In this paper, we will report not only large but also small RNA (100˜10b) are successfully trapped in relatively large microfluidic taper shape channel (width >10um). RNA are trapped in circular motion near the constricted position of taper shape channel, and the position and shape of the trapped RNA are controlled and make mode transition by changing the hydraulic and the electric force. Using this technique, smaller size molecule can be trapped in larger micro fluidic structure compared to the trap using dielectrophoresis. This technique is expected to establish easy and practical device as a direct total RNA extraction tool from living cells or tissues.

  5. Evaluation of conventional, protaper hand and protaper rotary instrumentation system for apical extrusion of debris, irrigants and bacteria- An in vitro randomized trial.

    PubMed

    Kalra, Pinky; Rao, Arathi; Suman, Ethel; Shenoy, Ramya; Suprabha, Baranya-Shrikrishna

    2017-02-01

    Endodontic instrumentation carries the risk of over extrusion of debris and bacteria. The technique used and the type of instrumentation influences this risk. The purpose of this study was to evaluate and compare the K-file, ProTaper hand and ProTaper rotary instrumentation systems for the amount of apically extruded debris, irrigant solution and intracanal bacteria. Experimental single blinded randomized type of in vitro study with sample of 30 single rooted teeth. Endodontic access cavities were prepared and the root canals were filled with the suspension of E. faecalis . Myers and Montogomery Model was used to collect apically extruded debris and irrigant. Canals were prepared using K files, Hand protapers and Protaper rotary files. Non Parametric test like Kruskal-Wallis and Mann-Whitney U test were applied to determine the significant differences among the group. Tests revealed statistically significant difference between the amount of debris and number of bacteria extruded by the ProTaper hand and the K-files. No statistically significant difference was observed between the amounts of irrigant extruded by the ProTaper hand and the K-file system. Statistically significant differences were observed between the amounts of bacteria and irrigant extruded by the ProTaper rotary and the Protaper hand. No statistically significant difference was observed between the amounts of debris extruded by the ProTaper hand and the K-file system. Amount of apical extrusion of irrigant solution, bacteria and debris are significantly greater with K File instruments and least with Protaper rotary instruments. Key words: Protaper, rotary, periapical extrusion.

  6. Variational theory of the tapered impedance transformer

    NASA Astrophysics Data System (ADS)

    Erickson, Robert P.

    2018-02-01

    Superconducting amplifiers are key components of modern quantum information circuits. To minimize information loss and reduce oscillations, a tapered impedance transformer of new design is needed at the input/output for compliance with other 50 Ω components. We show that an optimal tapered transformer of length ℓ, joining the amplifier to the input line, can be constructed using a variational principle applied to the linearized Riccati equation describing the voltage reflection coefficient of the taper. For an incident signal of frequency ωo, the variational solution results in an infinite set of equivalent optimal transformers, each with the same form for the reflection coefficient, each able to eliminate input-line reflections. For the special case of optimal lossless transformers, the group velocity vg is shown to be constant, with characteristic impedance dependent on frequency ωc = πvg/ℓ. While these solutions inhibit input-line reflections only for frequency ωo, a subset of optimal lossless transformers with ωo significantly detuned from ωc does exhibit a wide bandpass. Specifically, by choosing ωo → 0 (ωo → ∞), we obtain a subset of optimal low-pass (high-pass) lossless tapers with bandwidth (0, ˜ ωc) [(˜ωc, ∞)]. From the subset of solutions, we derive both the wide-band low-pass and high-pass transformers, and we discuss the extent to which they can be realized given fabrication constraints. In particular, we demonstrate the superior reflection response of our high-pass transformer when compared to other taper designs. Our results have application to amplifiers, transceivers, and other components sensitive to impedance mismatch.

  7. Brillouin lasing in single-mode tapered optical fiber with inscribed fiber Bragg grating array

    NASA Astrophysics Data System (ADS)

    Popov, S. M.; Butov, O. V.; Chamorovskiy, Y. K.; Isaev, V. A.; Kolosovskiy, A. O.; Voloshin, V. V.; Vorob'ev, I. L.; Vyatkin, M. Yu.; Mégret, P.; Odnoblyudov, M.; Korobko, D. A.; Zolotovskii, I. O.; Fotiadi, A. A.

    2018-06-01

    A tapered optical fiber has been manufactured with an array of fiber Bragg gratings (FBG) inscribed during the drawing process. The total fiber peak reflectivity is 5% and the reflection bandwidth is ∼3.5 nm. A coherent frequency domain reflectometry has been applied for precise profiling of the fiber core diameter and grating reflectivity both distributed along the whole fiber length. These measurements are in a good agreement with the specific features of Brillouin lasing achieved in the semi-open fiber cavity configuration.

  8. Development of Extinction Imagers for the Determination of Atmospheric Optical Extinction

    DTIC Science & Technology

    2014-08-01

    system resulting from the effects of both the optics and the camera system (including the electronics). The MSI sensor includes a fiber optic taper...small dots in Fig. 7-1 are due to the fiber optic taper in the system. The brighter region near the center is due to the lens optics. To apply the...a black target wliich was a hollow black box. Clearly it would be a major advantage if we could use "targets of opportunity" from a ship, and in

  9. Applying a tapered electrode on a porous ceramic support tube by masking a band inside the tube and drawing in electrode material from the outside of the tube by suction

    DOEpatents

    Vasilow, Theodore R.; Zymboly, Gregory E.

    1991-01-01

    An electrode is deposited on a support by providing a porous ceramic support tube (10) having an open end (14) and closed end (16); masking at least one circumferential interior band (18 and 18') inside the tube; evacuating air from the tube by an evacuation system (30), to provide a permeability gradient between the masked part (18 and 18') and unmasked part (20) of the tube; applying a liquid dispersion of solid electrode particles to the outside surface of the support tube, where liquid flows through the wall, forming a uniform coating (42) over the unmasked support part (20) and a tapered coating over the masked part (18 and 18').

  10. AC Electroosmotic Pumping in Nanofluidic Funnels.

    PubMed

    Kneller, Andrew R; Haywood, Daniel G; Jacobson, Stephen C

    2016-06-21

    We report efficient pumping of fluids through nanofluidic funnels when a symmetric AC waveform is applied. The asymmetric geometry of the nanofluidic funnel induces not only ion current rectification but also electroosmotic flow rectification. In the base-to-tip direction, the funnel exhibits a lower ion conductance and a higher electroosmotic flow velocity, whereas, in the tip-to-base direction, the funnel has a higher ion conductance and a lower electroosmotic flow velocity. Consequently, symmetric AC waveforms easily pump fluid through the nanofunnels over a range of frequencies, e.g., 5 Hz to 5 kHz. In our experiments, the nanofunnels were milled into glass substrates with a focused ion beam (FIB) instrument, and the funnel design had a constant 5° taper with aspect ratios (funnel tip width to funnel depth) of 0.1 to 1.0. We tracked ion current rectification by current-voltage (I-V) response and electroosmotic flow rectification by transport of a zwitterionic fluorescent probe. Rectification of ion current and electroosmotic flow increased with increasing electric field applied to the nanofunnel. Our results support three-dimensional simulations of ion transport and electroosmotic transport through nanofunnels, which suggest the asymmetric electroosmotic transport stems from an induced pressure at the junction of the nanochannel and nanofunnel tip.

  11. Assessment of Retention and Resistance Form of Tooth Preparations for All Ceramic Restorations using Digital Imaging Technique.

    PubMed

    Muruppel, Alex M; Thomas, Joyce; Saratchandran, Sudeep; Nair, Dinesh; Gladstone, Sheeba; Rajeev, Milen M

    2018-02-01

    This in vitro study evaluated the resistance form of die preparations for all ceramic restorations and, thereby, explored the concept of effective taper and its correlation between the ideal in theory and actual in the clinical situation by analyzing the digital images of the die preparations. Scanned digital images of 114 die preparations for all ceramic restorations (n = 114) were collected from a dental laboratory. All the images were also analyzed digitally using Adobe Photoshop® software to analyze the degree of taper (angle of convergence) of each preparation and then applied the Zuckerman's circle, and the Lewis perpendicular methods were used to measure the resistance form. For the current study, the overall average degree of taper was found to be 20.9° (range, 2-80°), which is more than what is recommended by most previous studies and also sharply greater than the textbook ideal of 3 to 6°. Mean degree of taper for maxillary was 17.56° (anterior-10.50°, posterior-23.7°), and for mandibular teeth, it was 25.22° (anterior-15°, posterior- 28.45°). Out of the 64 analyzed images of maxillary teeth, 61 presented resistance form, while 3 were without it. Out of the 50 mandibular teeth analyzed, 38 possessed resistance form, whereas 12 were without. All the anterior teeth showed resistance form irrespective of the arch. The degree of taper showed a significant relationship with resistance and retention form, which was inversely proportional to each other. The recommended "degree of taper" is not always the clinically achievable as advocated in textbooks, as it is modified by various factors in the actual clinical situation. The study provides scientific background regarding the relationship between the degree of taper with resistance and retention form, and the relationship was found to be inversely proportional to each other. The recommended "degree of taper" is not always the clinically achievable as advocated in textbooks, and it is modified by various modifying or limiting factors in the actual clinical situation.

  12. Refractive index and strain sensor based on twin-core fiber with a novel T-shaped taper

    NASA Astrophysics Data System (ADS)

    Zhang, Chuanbiao; Ning, Tigang; Li, Jing; Zheng, JingJing; Gao, Xuekai; Pei, Li

    2018-06-01

    A compact in-fiber Mach-Zehnder interferometer (MZI) based on twin-core fiber (TCF) with a novel T-shaped taper is proposed and demonstrated. The taper was firstly fabricated by a short section of TCF, and then spliced with a section of cleaved single mode fiber (SMF). When the light transmit into the TCF, multiple modes will be excited and will propagate within the TCF. In experiment, the proposed device had a maximum interferometric extinction ratio about 17 dB. And the refractive index (RI), strain, and temperature response properties of the sensor have been investigated, which show a relatively high RI, strain sensitivity and low temperature cross sensitivity. Hence, the sensor can be a suitable candidate in the biochemical and physical sensing applications. And due to its easy and controllable fabrication, the novel drawing technology can be applied to more multicore optical fibers.

  13. Strain-induced bi-thermoelectricity in tapered carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Algharagholy, L. A. A.; Pope, T.; Lambert, C. J.

    2018-03-01

    We show that carbon-based nanostructured materials are a novel testbed for controlling thermoelectricity and have the potential to underpin the development of new cost-effective environmentally-friendly thermoelectric materials. In single-molecule junctions, it is known that transport resonances associated with the discrete molecular levels play a key role in the thermoelectric performance, but such resonances have not been exploited in carbon nanotubes (CNTs). Here we study junctions formed from tapered CNTs and demonstrate that such structures possess transport resonances near the Fermi level, whose energetic location can be varied by applying strain, resulting in an ability to tune the sign of their Seebeck coefficient. These results reveal that tapered CNTs form a new class of bi-thermoelectric materials, exhibiting both positive and negative thermopower. This ability to change the sign of the Seebeck coefficient allows the thermovoltage in carbon-based thermoelectric devices to be boosted by placing CNTs with alternating-sign Seebeck coefficients in tandem.

  14. Integrated polarizers based on tapered highly birefringent photonic crystal fibers.

    PubMed

    Romagnoli, Priscila; Biazoli, Claudecir R; Franco, Marcos A R; Cordeiro, Cristiano M B; de Matos, Christiano J S

    2014-07-28

    This paper proposes and demonstrates the creation of sections with a high polarization dependent loss (PDL) in a commercial highly birefringent (polarization maintaining) photonic crystal fiber (PCF), via tapering with pressure applied to the holes. The tapers had a 1-cm-long uniform section with a 66% scale reduction, in which the original microstructure aspect ratio was kept by the pressure application. The resulting waveguides show polarizing action across the entire tested wavelength range, 1510-1600 nm, with a peak PDL of 35.3 dB/cm (c.f. ~1 dB/cm for a typical commercial polarizing fiber). The resulting structure, as well as its production, is extremely simple, and enable a small section with a high PDL to be obtained in a polarization maintaining PCF, meaning that the polarization axes in the polarizing and polarization maintaining sections are automatically aligned.

  15. The seating mechanics of head-neck modular tapers in vitro: Load-displacement measurements, moisture, and rate effects.

    PubMed

    Ouellette, Eric S; Shenoy, Aarti A; Gilbert, Jeremy L

    2018-04-01

    The mechanically assisted crevice corrosion performance of head-neck modular tapers is a significant concern in orthopedic biomaterials. Fretting crevice corrosion processes in modular tapers are thought to be influenced by a wide array of factors including seating mechanics of the junction, hence there is a need for in vitro test methods that can assess their performance. This study presented a test method to directly measure the load-displacement seating mechanics of modular tapers and used this method to compare the seating mechanics for different tapers, moisture, seating loads and seating rates. Seating mechanics were explored whereby the instantaneous load-displacement behavior of the head seating onto the neck is captured and used to define the mechanics of seating. Two distinct taper design/material combinations were assembled wet or dry using axially applied loads (500, 1,000, 2,000, and 4,000 N) at two loading rates of 100 and 10 4  N/s (n = 5 for each condition) using a servohydraulic test frame. The results showed that pull-off strength scaled with seating load and ranged between 43% and 68% of seating load depending on sample and wetness. Tapers seated wet had higher pull-off strengths (2,200 ± 300 N) than those seated dry (1,800 ± 200 N, p < 0.05). Seating mechanics (load-displacement plots) varied due to sample type and due to wetness with differences in seating energy, seating stiffness, and seating displacement. These results show the detailed mechanics of seating during assembly and provide significant insight into the complex interplay of factors associated with even "ideal" seating (axial, quasistatic) loading. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1164-1172, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  16. Effect of Pin Geometry on the Mechanical Strength of Friction-Stir-Welded Polypropylene Composite Plates

    NASA Astrophysics Data System (ADS)

    Kordestani, F.; Ashenai Ghasemi, F.; Arab, N. B. M.

    2017-09-01

    Friction stir welding (FSW) is a solid-state welding process, which has successfully been applied in aerospace and automotive industries for joining materials. The friction stir tool is the key element in the FSW process. In this study, the effect of four different tool pin geometries on the mechanical properties of two types of polypropylene composite plates, with 30% glass and carbon fiber, respectively, were investigated. For this purpose, four pins of different geometry, namely, a threaded-tapered pin, square pin, four-flute threaded pin, and threaded-tapered pin with a chamfer were made and used to carry out the butt welding of 5-mm-thick plates. The standard tensile and Izod impact tests were performed to evaluate the tensile strength and impact toughness of welded specimens. The results indicated that the threaded-tapered pin with a chamfer produced welds with a better surface appearance and higher tensile and impact strengths. The tests also showed that, with the threaded-tapered pin with a chamfer, the impact strength of the glass- and carbon-fiber composite welds were about 40 and 50%, respectively, of that of the base materials.

  17. Multiplex and simultaneous measurement of displacement and temperature using tapered fiber and fiber Bragg grating.

    PubMed

    Ji, Chongke; Zhao, Chun-Liu; Kang, Juan; Dong, Xinyong; Jin, Shangzhong

    2012-05-01

    A simple method to work out the multiplexing of tapered fiber based sensors is proposed and demonstrated. By cascading a tapered fiber with a fiber Bragg grating (FBG), the sensor head is provided with a wavelength identification, different FBGs provide the sensor heads with different reflective peaks and they can be distinguished in optical spectrum. By compositing several such sensor heads with a multi-channel beam splitter, a star-style topological structure sensor for multipoint sensing is achieved. At the same time, the output intensity at the peak wavelength is sensitive to one external physical parameter applied on the related FBG-cascaded tapered fiber and the central wavelength of the peak is only sensitive to temperature, so that that parameter and temperature can be measured simultaneously. A sensor for dual-point measurement of the displacement and temperature simultaneously is experimentally demonstrated by using a 2 × 2 coupler in this paper. Experiment results show that the sensor works well and the largest sensitivities reach to 0.11 dB/μm for displacement in the range of 0-400 μm, and ∼0.0097 nm/°C for temperature between 20 °C and 70 °C.

  18. A fiber-optic interferometer based on non-adiabatic fiber taper and long-period fiber grating for simultaneous measurement of magnetic field and temperature

    NASA Astrophysics Data System (ADS)

    Kang, Shouxin; Zhang, Hao; Liu, Bo; Lin, Wei; Zhang, Ning; Miao, Yinping

    2016-01-01

    A dual-parameter sensor based on a fiber-optic interferometer consisting of a non-adiabatic fiber taper and a long-period fiber grating (LPFG) integrated with magnetic nanoparticle fluids has been proposed and experimentally demonstrated. Due to the Mach-Zehnder interference induced by the concatenation of the fiber taper and long-period grating, an interferometric spectrum could be acquired within the transmission resonance spectral envelope of the LPFG. Thanks to different magnetic field and temperature sensitivities of difference interference dips, simultaneous measurement of the magnetic field intensity and environmental temperature could be achieved. Moreover, due to the variation in coupling coefficients of the fiber taper and the LPFG in response to the change of the applied magnetic field intensity, some of the interference dips would exhibit opposite magnetic-field-intensity-dependent transmission loss variation behavior. Magnetic field intensity and temperature sensitivities of 0.017 31 dB Oe-1 and 0.0315 dB K-1, and -0.024 55 dB Oe-1 and -0.056 28 dB K-1 were experimentally acquired for the experimentally monitored interference dips.

  19. Evaluation of conventional, protaper hand and protaper rotary instrumentation system for apical extrusion of debris, irrigants and bacteria- An in vitro randomized trial

    PubMed Central

    Kalra, Pinky; Suman, Ethel; Shenoy, Ramya; Suprabha, Baranya-Shrikrishna

    2017-01-01

    Background Endodontic instrumentation carries the risk of over extrusion of debris and bacteria. The technique used and the type of instrumentation influences this risk. Aim The purpose of this study was to evaluate and compare the K-file, ProTaper hand and ProTaper rotary instrumentation systems for the amount of apically extruded debris, irrigant solution and intracanal bacteria. Design Experimental single blinded randomized type of in vitro study with sample of 30 single rooted teeth. Endodontic access cavities were prepared and the root canals were filled with the suspension of E. faecalis. Myers and Montogomery Model was used to collect apically extruded debris and irrigant. Canals were prepared using K files, Hand protapers and Protaper rotary files. Statistical analysis Non Parametric test like Kruskal-Wallis and Mann-Whitney U test were applied to determine the significant differences among the group. Results Tests revealed statistically significant difference between the amount of debris and number of bacteria extruded by the ProTaper hand and the K-files. No statistically significant difference was observed between the amounts of irrigant extruded by the ProTaper hand and the K-file system. Statistically significant differences were observed between the amounts of bacteria and irrigant extruded by the ProTaper rotary and the Protaper hand. No statistically significant difference was observed between the amounts of debris extruded by the ProTaper hand and the K-file system. Conclusions Amount of apical extrusion of irrigant solution, bacteria and debris are significantly greater with K File instruments and least with Protaper rotary instruments. Key words:Protaper, rotary, periapical extrusion. PMID:28210445

  20. The wavelength-tunable tapered surface plasmon resonance fiber sensor based on separated input-output channels

    NASA Astrophysics Data System (ADS)

    Chen, Shimeng; Liu, Yun; Gao, Xiaotong; Liu, Xiuxin; Peng, Wei

    2014-11-01

    We present a wavelength-tunable tapered optics fiber surface Plasmon resonance (SPR) sensor by polishing the end faces of multimode fibers(MMF).Two hard plastic clad optical fibers joint closely and are used as the light input and output channels. Their end faces are polished to produce two oblique planes, which are coated with gold film to be the sensing surface and the front mirror. The presence of the tapered geometry formed by the two oblique planes in the orthogonal directions makes it possible to adjust incident angle through changing the tilt angles of the two end faces, so as to achieve tuning the SPR coupling wavelength-angle pair. Compared with previous researches based a tapered optic fiber probe, we report the approach theoretically increase the signal noise ratio (SNR) by separating incident and emergent light propagating in the different coordinate fiber. Since fabricating the sensing surface and the front mirror on the two fibers to replace one single fiber tip, there is more incident light can reach the sensing surface and satisfy SPR effective. In addition, this improvement in structure has advantages of large grinding and sensing area, which can lead to high sensitivity and simple manufacture process of the sensor. Experimental measurement demonstrates the sensor has a favorable SPR resonanceabsorption and the ability of measuring refractive index (RI) of aqueous solution. This novel tapered SPR sensor has the potential to be applied to the biological sensing field.

  1. Cerclage wires or cables for the management of intraoperative fracture associated with a cementless, tapered femoral prosthesis: results at 2 to 16 years.

    PubMed

    Berend, Keith R; Lombardi, Adolph V; Mallory, Thomas H; Chonko, Douglas J; Dodds, Kathleen L; Adams, Joanne B

    2004-10-01

    Initial stability is critical for fixation and survival of cementless total hip arthroplasty. Occasionally, a split of the calcar occurs intraoperatively. A review of 1,320 primary total hip arthroplasties with 2-year follow-up, performed between August 1985 and February 2001 using the Mallory-Head Porous tapered femoral component, revealed 58 hips in 55 patients with an intraoperative calcar fracture managed with single or multiple cerclage wires or cables and immediate full weight bearing. At 7.5 years average follow-up (range, 2-16 years), there were no revisions of the femoral component, radiographic failures, or patients with severe thigh pain, for a stem survival rate of 100%. Average Harris hip score improvement was 33.8 points. Fracture of the proximal femur occurs in approximately 4% of primary THAs using the Mallory-Head Porous femoral component. When managed intraoperatively with cerclage wire or cable, the mid- to long-term results appear unaffected with 100% femoral component survival at up to 16 years.

  2. An in vitro comparison of tracheostomy tube cuffs

    PubMed Central

    Maguire, Seamus; Haury, Frances; Jew, Korinne

    2015-01-01

    Introduction The Shiley™ Flexible adult tracheostomy tube with TaperGuard™ cuff has been designed through its geometry, materials, diameter, and wall thickness to minimize micro-aspiration of fluids past the cuff and to provide an effective air seal in the trachea while also minimizing the risk of excessive contact pressure on the tracheal mucosa. The cuff also has a deflated profile that may allow for easier insertion through the stoma site. This unique design is known as the TaperGuard™ cuff. The purpose of the observational, in vitro study reported here was to compare the TaperGuard™ taper-shaped cuff to a conventional high-volume low-pressure cylindrical-shaped cuff (Shiley™ Disposable Inner Cannula Tracheostomy Tube [DCT]) with respect to applied tracheal wall pressure, air and fluid sealing efficacy, and insertion force. Methods Three sizes of tracheostomy tubes with the two cuff types were placed in appropriately sized tracheal models and lateral wall pressure was measured via pressure-sensing elements on the inner surface. Fluid sealing performance was assessed by inflating the cuffs within the tracheal models (25 cmH2O), instilling water above the cuff, and measuring fluid leakage past the cuff. To measure air leak, tubes were attached to a test lung and ventilator, and leak was calculated by subtracting the average exhaled tidal volume from the average delivered tidal volume. A tensile test machine was used to measure insertion force for each tube with the cuff deflated to simulate clinical insertion through a stoma site. Results The average pressure exerted on the lateral wall of the model trachea was lower for the taper-shaped cuff than for the cylindrical cuff under all test conditions (P<0.05). The taper-shaped cuff also demonstrated a more even, lower pressure distribution along the lateral wall of the model trachea. The average air and fluid seal performance with the taper-shaped cuff was significantly improved, when compared to the cylindrical-shaped cuff, for each tube size tested (P<0.05). The insertion force for the taper-shaped cuff was ~40% less than that for the cylindrical-shaped cuff. Conclusion In a model trachea, the Shiley™ Flexible Adult tracheostomy tube with TaperGuard™ cuff, when compared to the Shiley™ Disposable Inner Cannula Tracheostomy tube with cylindrical cuff, exerted a lower average lateral wall pressure and a more evenly distributed pressure. In addition, it provided more effective fluid and air seals and required less force to insert. PMID:25960679

  3. Continuous distal migration and internal rotation of the C-stem prosthesis without any adverse clinical effects: an RSA study of 33 primary total hip arthroplasties followed for up to ten years.

    PubMed

    von Schewelov, T; Carlsson, A; Sanzén, L; Besjakov, J

    2014-05-01

    In 2005, we demonstrated that the polished triple-tapered C-stem at two years had migrated distally and rotated internally. From that series, 33 patients have now been followed radiologically, clinically and by radiostereometric analysis (RSA) for up to ten years. The distal migration within the cement mantle had continued and reached a mean of 2 mm (0.5 to 4.0) at ten years. Internal rotation, also within the cement mantle, was a mean 3.8° (external 1.6° to internal 6.6°) The cement mantle did not show any sign of migration or loosening in relation to the femoral bone. There were no clinical or radiological signs indicating that the migration or rotation within the cement mantle had had any adverse effects for the patients.

  4. Parabolic tapers for overmoded waveguides

    DOEpatents

    Doane, J.L.

    1983-11-25

    A waveguide taper with a parabolic profile, in which the distance along the taper axis varies as the square of the tapered dimension, provides less mode conversion than equal length linear tapers and is easier to fabricate than other non-linear tapers.

  5. Should total hip arthroplasty femoral components be designed to subside? A radiostereometric analysis study of the Charnley Elite and Exeter stems.

    PubMed

    Alfaro-Adrián, J; Gill, H S; Murray, D W

    2001-08-01

    The Charnley Elite and the Exeter stems have different design concepts: The former is designed not to subside, whereas the latter is expected to subside. This radiostereometric analysis study compares the early migration of the 2 stems. For both implants, the 1st year migration was about 4 times faster than the 2nd year. The Exeter migration was predominantly distal (1 mm/y in the 1st year). It also showed slight collapse into valgus, and the head migrated slowly posteriorly (0.3 mm/y in the 1st year). In contrast, the Elite had slow distal migration (0.2 mm/y in the 1st year) and rapid posterior head migration (0.8 mm/y in the 1st year). Four Elites and no Exeters had rapid posterior head migration rates (mean 2.8 mm/y in the 1st year and 0.8 mm/y in the 2nd year). The Elite and the Exeter stems have fundamentally different early patterns of migration, which affect their long-term function; 20% of the Elites and none of the Exeters had rapid posterior head migration in the 1st year and the 2nd year and are likely to fail early. Polished, collarless, tapered designs, such as the Exeter, may be more forgiving than conventional stems designed not to subside.

  6. Further Development of Ko Displacement Theory for Deformed Shape Predictions of Nonuniform Aerospace Structures

    NASA Technical Reports Server (NTRS)

    Ko, William L.; Fleischer, Van Tran

    2009-01-01

    The Ko displacement theory previously formulated for deformed shape predictions of nonuniform beam structures is further developed mathematically. The further-developed displacement equations are expressed explicitly in terms of geometrical parameters of the beam and bending strains at equally spaced strain-sensing stations along the multiplexed fiber-optic sensor line installed on the bottom surface of the beam. The bending strain data can then be input into the displacement equations for calculations of local slopes, deflections, and cross-sectional twist angles for generating the overall deformed shapes of the nonuniform beam. The further-developed displacement theory can also be applied to the deformed shape predictions of nonuniform two-point supported beams, nonuniform panels, nonuniform aircraft wings and fuselages, and so forth. The high degree of accuracy of the further-developed displacement theory for nonuniform beams is validated by finite-element analysis of various nonuniform beam structures. Such structures include tapered tubular beams, depth-tapered unswept and swept wing boxes, width-tapered wing boxes, and double-tapered wing boxes, all under combined bending and torsional loads. The Ko displacement theory, combined with the fiber-optic strain-sensing system, provide a powerful tool for in-flight deformed shape monitoring of unmanned aerospace vehicles by ground-based pilots to maintain safe flights.

  7. Stability analysis of a two-stage tapered gyrotron traveling-wave tube amplifier with distributed losses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hung, C. L.; Lian, Y. H.; Cheng, N. H.

    2012-11-15

    The two-stage tapered gyrotron traveling-wave tube (gyro-TWT) amplifier has achieved wide bandwidth in the millimeter wave range. However, possible oscillations in each stage limit this amplifier's operating beam current and thus its output power. To further enhance the amplifier's stability, distributed losses are applied to the interaction circuit of the two-stage tapered gyro-TWT. A self-consistent particle-tracing code is used for analyzing the beam-wave interactions. The stability analysis includes the effects of the wall losses and the length of each stage on the possible oscillations. Simulation results reveal that the distributed-loss method effectively stabilizes all the oscillations in the two stages.more » Under stable operating conditions, the device is predicted to produce a peak power of 60 kW with an efficiency of 29% and a saturated gain of 52 dB in the Ka-band. The 3-dB bandwidth is 5.7 GHz, which is approximately 16% of the center frequency.« less

  8. Efficient system modeling for a small animal PET scanner with tapered DOI detectors.

    PubMed

    Zhang, Mengxi; Zhou, Jian; Yang, Yongfeng; Rodríguez-Villafuerte, Mercedes; Qi, Jinyi

    2016-01-21

    A prototype small animal positron emission tomography (PET) scanner for mouse brain imaging has been developed at UC Davis. The new scanner uses tapered detector arrays with depth of interaction (DOI) measurement. In this paper, we present an efficient system model for the tapered PET scanner using matrix factorization and a virtual scanner geometry. The factored system matrix mainly consists of two components: a sinogram blurring matrix and a geometrical matrix. The geometric matrix is based on a virtual scanner geometry. The sinogram blurring matrix is estimated by matrix factorization. We investigate the performance of different virtual scanner geometries. Both simulation study and real data experiments are performed in the fully 3D mode to study the image quality under different system models. The results indicate that the proposed matrix factorization can maintain image quality while substantially reduce the image reconstruction time and system matrix storage cost. The proposed method can be also applied to other PET scanners with DOI measurement.

  9. Supercontinuum generation in a tapered tellurite microstructured optical fiber

    NASA Astrophysics Data System (ADS)

    Yan, X.; Ohishi, Y.

    2014-07-01

    Supercontinuum generation (SCG) was investigated in tapered tellurite microstructured optical fibers (MOFs) for various taper profiles. We emphasize on the procedure for finding the dispersion profile that achieve the best width of the SC spectra. An enhancement of the SCG is achieved by varying the taper waist diameter along its length in a carefully designed, and an optimal degree of tapering is found to exist for tapers with an axially uniform waist. We also show the XFROG spectrograms of the pulses propagating through different tapered fibers, confirming the optimized taper conditions.

  10. Extrusion of Debris from Primary Molar Root Canals following Instrumentation with Traditional and New File Systems.

    PubMed

    Thakur, Bhagyashree; Pawar, Ajinkya M; Kfir, Anda; Neelakantan, Prasanna

    2017-11-01

    To assess the amount of debris extruded apically during instrumentation of distal canals of extracted primary molars by three instrument systems [ProTaper Universal (PTU), ProTaper NEXT (PTN), and self-adjusting file (SAF)] compared with conventional stainless steel hand K-files (HF, control). Primary mandibular molars (n = 120) with a single distal canal were selected and randomly divided into four groups (n = 30) for root canal instrumentation using group I, HF (to size 0.30/0.02 taper), group II, PTU (to size F3), group III, PTN (to size X3), and group IV, SAF. Debris extruded during instrumentation was collected in preweighed Eppendorf tubes, stored in an incubator at 70°C for 5 days and then weighed. Statistical analysis was performed by one-way analysis of variance (ANOVA), followed by Turkey's post hoc test (p = 0.05). All the groups resulted in extrusion of debris. There was statistically significant difference (p < 0.001) in the debris extrusion between the three groups: HF (0.00133 ± 0.00012), PTU (0.00109 ± 0.00005), PTN (0.00052 ± 0.00008), and SAF (0.00026 ± 0.00004). Instrumentation with SAF resulted in the least debris extrusion when used for shaping root canals of primary molar teeth. Debris extrusion in primary teeth poses an adverse effect on the stem cells and may also alter the permanent dental germ. Debris extrusion is rarely reported for primary teeth and it is important for the clinician to know which endodontic instrumentation leads to less extrusion of debris.

  11. [INVITED] Magnetic field vector sensor by a nonadiabatic tapered Hi-Bi fiber and ferrofluid nanoparticles

    NASA Astrophysics Data System (ADS)

    Layeghi, Azam; Latifi, Hamid

    2018-06-01

    A magnetic field vector sensor based on super-paramagnetic fluid and tapered Hi-Bi fiber (THB) in fiber loop mirror (FLM) is proposed. A two-dimensional detection of external magnetic field (EMF) is experimentally demonstrated and theoretically simulated by Jones matrix to analyze the physical operation in detail. A birefringence is obtained due to magnetic fluid (MF) in applied EMF. By surrounding the THB with MF, a tunable birefringence of MF affect the transmission of the sensor. Slow and fast axes of this obtained birefringence are determined by the direction of applied EMF. In this way, the transmission response of the sensor is depended on the angle between the EMF orientation and the main axes of polarization maintaining fiber (PMF) in FLM. The wavelength shift and intensity shift versus EMF orientation show a sinusoidal behavior, while the applied EMF is constant. Also, the changes in the intensity of EMF in a certain direction results in wavelength shift in the sensor spectrum. The maximum wavelength sensitivity of 214 pm/mT is observed.

  12. White light supercontinuum generation in a Y-shaped microstructured tapered fiber pumped at 1064 nm.

    PubMed

    Cascante-Vindas, J; Díez, A; Cruz, J L; Andrés, M V

    2010-07-05

    We report the generation of supercontinuum in a Ge-doped Y-shape tapered fiber pumped at 1064 nm in the ns pump regime. The taper was designed to have long taper transitions and a taper waist with a core diameter of 0.9 mum. The large air-filling fraction and diameter of the air-hole microstructure reduces the confinement loss at long wavelengths so, enabling the extension of the spectrum to longer wavelengths. Along the taper transition the zero-dispersion wavelength decreases as the diameter of the taper becomes smaller. The spectral components generated along the taper transition pump the taper waist, enhancing the generation of short wavelengths. A flat spectrum spanning from 420 nm to 1850 nm is reported.

  13. Mechanics and complications of reverse shoulder arthroplasty: morse taper failure analysis and prospective rectification

    NASA Astrophysics Data System (ADS)

    Hoskin, HLD; Furie, E.; Collins, W.; Ganey, TM; Schlatterer, DR

    2017-05-01

    Since Sir John Charnley began his monumental hip arthroplasty work in 1958, clinical researchers have been incrementally improving longevity and functionality of total joint systems, although implant failure occurs on occasion. The purpose of this study is to report the fracture of the humeral tray Morse taper of a reverse total shoulder system (RTSS), which to date has not been reported with metallurgic analysis for any RTSS. There was no reported antecedent fall, motor vehicle collision, or other traumatic event prior to implant fracture in this case. Analysis was performed on the retrieved failed implant by Scanning Electron Microscopy (SEM) and Electron Dispersion Spectroscopy (EDS) in an attempt to determine the failure method, as well as to offer improvements for future implants. At the time of revision surgery all explants were retained from the left shoulder of a 61-year old male who underwent a non-complicated RTSS 4 years prior. The explants, particularly the cracked humeral tray, were processed as required for SEM and EDS. Analysis was performed on the failure sites in order to determine the chemical composition of the different parts of the implant, discover the chemical composition of the filler metal used during the electron beam welding process, and to detect any foreign elements that could suggest corrosion or other evidence of failure etiology. Gross visual inspection of all explants revealed that implant failure was a result of dissociation of the taper from the humeral tray at the weld, leaving the Morse taper embedded in the humeral stem while the tray floated freely in the patient’s shoulder. SEM further confirmed the jagged edges noted grossly at the weld fracture site, both suggesting failure due to torsional forces. EDS detected elevated levels of carbon and oxygen at the fracture site on the taper only and not on the humeral tray. In order to determine the origin of the high levels of C and O, it was considered that in titanium alloys, C and O are used as stabilizers that help raise the temperature at which titanium can be cast. Since the presence of stabilizers reduces ductility and fatigue strength, all interstitial elements are removed after casting. Considering this, the presence of C and O suggests that not all of the interstitials were removed during the manufacturing process, resulting in decreased fatigue strength. Further destructive analytical testing would verify weld quality and failure mode. RTSSs are quite successful in select patients not amenable to traditional shoulder arthroplasty options. This case report highlights how an implant may function well for several years and then suddenly fail without warning. SEM and EDS analysis suggest that residual C and O in the taper lowered the metal implant’s integrity, leading to torsional cracking at the weld junction of the humeral tray and the taper. The elevated levels of C and O measured at fracture sites on both the tray and the taper suggest poor quality filler metal or failure to remove all interstitial elements after casting. In both cases, the results would be decreased fatigue strength and overall toughness, leading to mechanical failure. A manufacturer’s recall of all implants soon followed the reporting of this implant failure; subsequently, the metal materials were changed from Ti6Al4V to both titanium alloy and cobalt-chrome alloy (Co-Cr-Mo). Time will tell if the alterations were sufficient.

  14. [A new method of osteosynthesis in proximal humeral fractures: a new internal fixation device. Apropos of 17 cases followed over more than 2 years].

    PubMed

    Doursounian, L; Grimberg, J; Cazeau, C; Touzard, R C

    1996-01-01

    The authors describe a new internal fixation device, and report on 17 proximal humeral fractures managed with this technique. The fracture patterns, using Neer's classification were: 9 displaced three-part fractures, 4 displaced four-part fractures and 4 interior fracture dislocations (mean age of the patients: 70 years). The device is a two-part titanium device. The humeral component has a long vertical stem cemented in the humeral shaft; and a short proximal portion set at an angle of 135 degrees on the stem, with a neck and a Morse taper cone. The other part is a crown-shaped stapple, whose base is a perforated disk with a central Morse taper socket. The rim of the crown has five prongs which, together with the central socket, are impacted in the cancellous bone of the humeral head. The taper of the humeral component is inserted into the central socket of the stapple to provide fracture fixation. Tuberosities are reattached to the shaft with non absorbable sutures. Mean follow-up was 29 months. The global ratings were as follows: 4 excellent results, 6 good results, 4 fair results, 3 poor results. Mean active forward flexion: 100 degrees, and mean active external rotation 22 degrees. After exclusion of the 4 fracture-dislocations, the global rating became: 4 excellent results, 5 good results, 3 fair results, 1 poor result. Mean active forward flexion: 110 degrees and mean active external rotation: 31.5 degrees. There were no case of avascular necrosis in 13 patients. Complications requiring surgery occurred in one case: an upper protrusion of the stapple which required replacement of the stapple by a prosthetic humeral head. Other complications included: 2 asymptomatic partial protrusions of the stapple, 2 complete and two partial avascular necrosis in fracture-dislocations. Except for the fracture-dislocations our device confers several major benefits. The humeral head is preserved. Typical problems associated with joint replacement (dislocations, loosening, glenoid degeneration) are avoided. Humeral head conservation enhances healing of the tuberosities. Fixation could always be obtained, regardless of the complexity of the fracture pattern. An hemiarthroplasty (e.g. in case of avascular necrosis) is possible by the modular design of the device.

  15. Waveguide-loaded silica fibers for coupling to high-index micro-resonators

    NASA Astrophysics Data System (ADS)

    Latawiec, P.; Burek, M. J.; Venkataraman, V.; Lončar, M.

    2016-01-01

    Tapered silica fibers are often used to rapidly probe the optical properties of micro-resonators. However, their low refractive index precludes phase-matching when coupling to high-index micro-resonators, reducing efficiency. Here, we demonstrate efficient optical coupling from tapered fibers to high-index micro-resonators by loading the fibers with an ancillary adiabatic waveguide-coupler fabricated via angled-etching. We demonstrate greatly enhanced coupling to a silicon multimode micro-resonator when compared to coupling via the bare fiber only. Signatures of resonator optical bistability are observed at high powers. This scheme can be applied to resonators of any size and material, increasing the functional scope of fiber coupling.

  16. Tapered oral dexamethasone for the acute chest syndrome of sickle cell disease

    PubMed Central

    Quinn, Charles T.; Stuart, Marie J.; Kesler, Karen; Ataga, Kenneth I.; Wang, Winfred C.; Styles, Lori; Smith-Whitley, Kim; Wun, Ted; Raj, Ahsok; Hsu, Lewis L.; Krishnan, Suba; Kuypers, Frans A; Setty, B. N. Yamaja; Rhee, Seungshin; Key, Nigel S.; Buchanan, George R.

    2011-01-01

    Summary Tapered oral dexamethasone for acute chest syndrome (ACS) in sickle cell anaemia was studied using a novel ACS assessment tool and investigational biomarkers. Twelve participants were randomized (mean age 17.3 years) before early study termination. Dexamethasone decreased duration of hospitalization for ACS by 20.8 h compared to placebo (P=0.024). Rebound pain occurred in both groups (3 dexamethasone vs. 1 placebo). Overall, dexamethasone decreased the leucocyte activation biomarker, sL-selectin; however, participants with rebound pain had higher sL-selectin within 24 h of treatment (dexamethasone or placebo). This ACS assessment tool was feasibly applied, and sL-selectin is a promising biomarker of ACS therapy. PMID:21848879

  17. Stress Analysis of Columns and Beam Columns by the Photoelastic Method

    NASA Technical Reports Server (NTRS)

    Ruffner, B F

    1946-01-01

    Principles of similarity and other factors in the design of models for photoelastic testing are discussed. Some approximate theoretical equations, useful in the analysis of results obtained from photoelastic tests are derived. Examples of the use of photoelastic techniques and the analysis of results as applied to uniform and tapered beam columns, circular rings, and statically indeterminate frames, are given. It is concluded that this method is an effective tool for the analysis of structures in which column action is present, particularly in tapered beam columns, and in statically indeterminate structures in which the distribution of loads in the structures is influenced by bending moments due to axial loads in one or more members.

  18. Effect of tracheal tube cuff shape on fluid leakage across the cuff: an in vitro study.

    PubMed

    Dave, M H; Frotzler, A; Spielmann, N; Madjdpour, C; Weiss, M

    2010-10-01

    This study compared the fluid leakage in the new 'tapered' shaped against the classic 'cylindrical' shaped tracheal tube cuffs when placed in different sized tracheas. The 7.5 mm internal diameter (ID) tracheal tube cuffs-Tapered Seal Guard (TSG), Standard Seal Guard (SSG), Hi-Lo, Microcuff, Ruesch, and Portex Profile-were compared in an in vitro apparatus. Vertical artificial tracheas with 16, 20, and 22 mm ID were intubated, 5 ml clear water was applied above the unlubricated tube cuffs, and fluid leakage was measured up to 60 min. Data of tapered vs non-tapered tube cuffs (16 observations) were compared for each tracheal diameter using the Mann-Whitney test. Median (range) fluid leakage (ml) at 60 min was 2.14 (0.05-4.88), 1.14 (0.00-4.84), and 0.13 (0.00-1.32), respectively, for 16, 20, and 22 mm tracheas in the TSG tube studies when compared with 4.58 (0.44-4.88), 2.21 (0.00-4.81), and 0.00 (0.00-4.81) in the SSG tube and 4.54 (1.54-4.82), 0.90 (0.00-4.49), and 4.85 (4.40-4.99) in the Microcuff tube studies. Leakage in all polyvinylchloride (PVC) tube cuffs was almost complete (5 ml) within 5 min (P<0.001). The tapered PU tube cuff was as effective as the cylindrical PU cuffs in smaller tracheal diameters and was more efficient than the cylindrical Microcuff PU tube cuff in larger tracheal diameter in preventing subglottic fluid leakage across the tube cuff tested in this in vitro study. PVC tube cuffs leaked much more and faster than PU cuffs.

  19. Suitability of Secondary PEEK Telescopic Crowns on Zirconia Primary Crowns: The Influence of Fabrication Method and Taper.

    PubMed

    Merk, Susanne; Wagner, Christina; Stock, Veronika; Eichberger, Marlis; Schmidlin, Patrick R; Roos, Malgorzata; Stawarczyk, Bogna

    2016-11-08

    This study investigates the retention load (RL) between ZrO₂ primary crowns and secondary polyetheretherketone (PEEK) crowns made by different fabrication methods with three different tapers. Standardized primary ZrO₂ crowns were fabricated with three different tapers: 0°, 1°, and 2° ( n = 10/group). Ten secondary crowns were fabricated (i) milled from breCam BioHPP blanks (PM); (ii) pressed from industrially fabricated PEEK pellets (PP) (BioHPP Pellet); or (iii) pressed from granular PEEK (PG) (BioHPP Granulat). One calibrated operator adjusted all crowns. In total, the RL of 90 secondary crowns were measured in pull-off tests at 50 mm/min, and each specimen was tested 20 times. Two- and one-way ANOVAs followed by a Scheffé's post-hoc test were used for data analysis ( p < 0.05). Within crowns with a 0° taper, the PP group showed significantly higher retention load values compared with the other groups. Among the 1° taper, the PM group presented significantly lower retention loads than the PP group. However, the pressing type had no impact on the results. Within the 2° taper, the fabrication method had no influence on the RL. Within the PM group, the 2° taper showed significantly higher retention load compared with the 1° taper. The taper with 0° was in the same range value as the 1° and 2° tapers. No impact of the taper on the retention value was observed between the PP groups. Within the PG groups, the 0° taper presented significantly lower RL than the 1° taper, whereas the 2° taper showed no differences. The fabrication method of the secondary PEEK crowns and taper angles showed no consistent effect within all tested groups.

  20. Influence of material coupling and assembly condition on the magnitude of micromotion at the stem-neck interface of a modular hip endoprosthesis.

    PubMed

    Jauch, S Y; Huber, G; Hoenig, E; Baxmann, M; Grupp, T M; Morlock, M M

    2011-06-03

    Hip prostheses with a modular neck exhibit, compared to monobloc prostheses, an additional interface which bears the risk of fretting as well as corrosion. Failures at the neck adapter of modular prostheses have been observed for a number of different designs. It has been speculated that micromotions at the stem-neck interface were responsible for these implant failures. The purpose of this study was to investigate the influence of material combinations and assembly conditions on the magnitude of micromotions at the stem-neck interface during cyclic loading. Modular (n = 24) and monobloc (n = 3) hip prostheses of a similar design (Metha, Aesculap AG, Tuttlingen, Germany) were subjected to mechanical testing according to ISO 7206-4 (F(min) = 230N, F(max) = 2300N, f = 1Hz, n = 10,000 cycles). The neck adapters (Ti-6Al-4V or Co-Cr29-Mo alloy) were assembled with a clean or contaminated interface. The micromotion between stem and neck adapter was calculated at five reference points based on the measurements of the three eddy current sensors. The largest micromotions were observed at the lateral edge of the stem-neck taper connection, which is in accordance with the crack location of clinically failed prostheses. Titanium neck adapters showed significantly larger micromotions than cobalt-chromium neck adapters (p = 0.005). Contaminated interfaces also exhibited significantly larger micromotions (p < 0.001). Since excessive micromotions at the stem-neck interface might be involved in the process of implant failure, special care should be taken to clean the interface prior to assembly and titanium neck adapters with titanium stems should generally be used with caution. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Statistical analysis of interfacial gap in a cementless stem FE model.

    PubMed

    Park, Youngbae; Choi, Donok; Hwang, Deuk Soo; Yoon, Yong-San

    2009-02-01

    In cementless total hip arthroplasty, a fair amount of interfacial gap exists between the femoral stem and the bone. However, the effect of these gaps on the mechanical stability of the stem is poorly understood. In this paper, a finite element model with various interfacial gap definitions is used to quantify the effect of interfacial gaps on the primary stability of a Versys Fiber Metal Taper stem under stair climbing loads. In the first part, 500 random interfacial gap definitions were simulated. The resulting micromotion was approximately inversely proportional to the contact ratio, and the variance of the micromotion was greater with a lower contact ratio. Moreover, when the magnitude of the micromotion was compared between the gap definitions that had contact at a specific site and those that had no contact at that site, it was found that gaps located in the proximal-medial region of the stem surface had the most important effect on the micromotion. In a second trial, 17 gap definitions mimicking a gap pattern that has been observed experimentally were simulated. For a given contact ratio, the micromotion observed in the second trial was lower than the average result of those in the first, where the gaps were placed randomly. In either trial, when the contact ratio was higher than 40%, the micromotion showed no significant difference (first trial) or a gentle slope (-0.24 mum% in the second trial) in relation to the contact ratio. Considering the reported contact ratios for properly implanted stems, variations in the amount of interfacial gap would not likely cause a drastic difference in micromotion, and this effect could be easily overshadowed by other clinical factors. In conclusion, differences in interfacial gaps are not expected to have a noticeable effect on the clinical micromotion of this cementless stem.

  2. Application of fiber tapers in astronomy

    NASA Astrophysics Data System (ADS)

    Marcel, Jaclyn; Haynes, Roger; Bland-Hawthorn, Joss

    2006-06-01

    Fiber tapers have the potential to significantly advance instrument technology into the realm of fully integrated optical systems. Our initial investigation was directed at the use of fiber tapers as f-ratio transformation devices. Using a technique developed for testing focal ratio degradation (FRD), a collimated light source was injected at different angles into various fiber taper samples and the far-field profile of the fiber output was observed. We compare the FRD present in the optical fiber tapers with conventional fibers and determine how effectively fiber tapers perform as image converters. We demonstrate that while silica fiber tapers may have slightly more intrinsic FRD than conventional fibers they still show promise as adiabatic mode transformers and are worth investigating further for their potential use in astronomical instruments. In this paper we present a brief review of the current status of fiber tapers with particular focus on the astronomical applications. We demonstrate the conservation of etendue in the taper transformation process and present the experimental results for a number of different taper profiles and manufacturers.

  3. [Shaping ability of multi-taper nickel-titanium files in simulated resin curved root canal].

    PubMed

    Luo, Hong-Xia; Huang, Ding-Ming; Jia, Liu-He; Luo, Shi-Gao; Gao, Xiao-Jie; Tan, Hong; Zhou, Xue-Dong

    2006-08-01

    To compare the shaping ability of ISO standard stainless steel K files and multi-taper ProTaper nickel-titanium files in simulated resin curved root canals. METHODS Thirty simulated resin root canals were randomly divided into three groups and prepared by stainless steel K files, hand ProTaper, rotary ProTaper, respectively. The amount of material removed from inner and outer wall and canal width after canal preparation was measured, while the canal curvature before and after canal preparation and canals aberrations were recorded. The stainless steel K files removed more material than hand ProTaper and rotary ProTaper at the outer side of apex and inner side of curvature (P < 0.05). The mean degree of straightening in stainless steel K files group was significantly bigger than in ProTaper group (P < 0.05). The canals prepared by ProTaper had no evident aberration. The shaping ability of ProTaper is better than stainless steel K files.

  4. Influence of cross-sectional design and dimension on mechanical behavior of nickel-titanium instruments under torsion and bending: a numerical analysis.

    PubMed

    Zhang, En-Wei; Cheung, Gary S P; Zheng, Yu-Feng

    2010-08-01

    The aim of this study was to examine the influence of the cross-sectional configuration and dimensions (size and taper) on the torsional and bending behavior of nickel-titanium rotary instruments, taking into account the nonlinear mechanical properties of material. Ten cross-sectional configurations, square, triangular, U-type, S-type (large and small), convex-triangle, and 4 proprietary ones (Mani NRT and RT2, Quantec, and Mtwo), were analyzed under torsion or bending by using a 3-dimensional finite element method. The von Mises stresses were correlated with the critical values for various phases of the nickel-titanium material. Different loading conditions led to unequal patterns of stress distribution. Increasing the applied torque or bending angle resulted in a rise in the corresponding stresses in the instrument. Favorable stress distribution without dangerous stress concentration was observed if the material was undergoing superelastic transformation at that applied load. The ultimate strength of the material was not exceeded when the instrument was bent up to a 50-degree curvature. On the other hand, when a torsional moment of greater than 1.0 N*mm was applied, the maximum stresses developed in some designs would exceed the ultimate strength of the material. Little variation in the von Mises stresses was observed for instruments of different nominal sizes and tapers on bending to similar extent. The cross-sectional design has a greater impact than taper or size of the instrument on the stresses developed in the instrument under either torsion or bending. Certain cross-sectional configurations are prone to fracture by excess torsional stresses. Copyright 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  5. Experimental Investigation of Superradiance in a Tapered Free-Electron Laser Amplifier

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hidaka, Y.; She, Y.; Murphy, J.B.

    2011-03-28

    We report experimental studies of the effect of undulator tapering on superradiance in a single-pass high-gain free-electron laser (FEL) amplifier. The experiments were performed at the Source Development Laboratory (SDL) of National Synchrotron Light Source (NSLS). Efficiency was nearly tripled with tapering. Both the temporal and spectral properties of the superradiant FEL along the uniform and tapered undulator were experimentally characterized using frequency-resolved optical gating (FROG) images. Numerical studies predicted pulse broadening and spectral cleaning by undulator tapering Pulse broadening was experimentally verified. However, spectral cleanliness degraded with tapering. We have performed first experiments with a tapered undulator and amore » short seed laser pulse. Pulse broadening with tapering expected from simulations was experimentally confirmed. However, the experimentally obtained spectra degraded with tapering, whereas the simulations predicted improvement. A further numerical study is under way to resolve this issue.« less

  6. Where science meets practice: Olympic coaches' crafting of the tapering process.

    PubMed

    Ritchie, Darren; Allen, Justine B; Kirkland, Andrew

    2018-05-01

    Although there is research providing physiologically-based guidance for the content of the taper, this study was the first to examine how coaches actually implement the taper. The purpose of this study was to examine the taper planning and implementation processes of successful Olympic coaches leading up to major competitions and how they learned about tapering. Seven track and field coaches participated in semi-structured interviews exploring their tapering processes. To be considered for inclusion, coaches were required to have coached one or more athletes to an Olympic or Paralympic medal. Through a process of axial and open coding interview transcripts were analysed and lower and higher order themes developed describing the coaches' tapering processes. Our findings indicate that the strategies employed to achieve the desired physiological adaptions of the taper were consistent with research (e.g., reduction in volume whilst maintaining intensity and frequency). However, our findings also suggest that tapering is far from a straight forward "textbook" process. The taper was not restricted to physiological outcomes with coaches considering athletes' psychological as well as physical state. Coaches also involved the athlete in the process, adapted the taper to the athlete, continually monitored its progress, and adapted it further as required.

  7. Effects of Magnetic field on Peristalsis transport of a Carreau Fluid in a tapered asymmetric channel

    NASA Astrophysics Data System (ADS)

    Prakash, J.; Balaji, N.; Siva, E. P.; Kothandapani, M.; Govindarajan, A.

    2018-04-01

    The paper is concerned with effects of a uniform applied magnetic field on a Carreau fluid flow in a tapered asymmetric channel with peristalsis. The channel non-uniform & asymmetry are formed by choosing the peristaltic wave train on the tapered walls to have different amplitude and phase (ϕ). The governing equations of the Carreau model in two - dimensional peristaltic flow phenomena are constructed under assumptions of long wave length and low Reynolds number approximations. The simplified non - linear governing equations are solved by regular perturbation method. The expressions for pressure rise, frictional force, velocity and stream function are determined and the effects of different parameters like non-dimensional amplitudes walls (a and b), non - uniform parameter (m), Hartmann number (M), phase difference (ϕ),power law index (n) and Weissenberg numbers (We) on the flow characteristics are discussed. It is viewed that the rheological parameter for large (We), the curves of the pressure rise are not linear but it behaves like a Newtonian fluid for very small Weissenberg number.

  8. The effects of different nickel-titanium instruments on dentinal microcrack formations during root canal preparation.

    PubMed

    Ustun, Yakup; Aslan, Tugrul; Sagsen, Burak; Kesim, Bertan

    2015-01-01

    The aim of the present study was to investigate the incidence of dentinal microcracks caused by different preparation techniques. 120 extracted human mandibular incisor teeth were divided into five experimental groups and one control group (n = 20): Group 1: Hand preparation with balanced force technique up to #25 K-file. Group 2: Preparation with only ProTaper F2 instrument in a reciprocating movement. Group 3: Preparation with Reciproc R25 instrument in a reciprocating movement. Group 4: Preparation with ProTaper instruments up to F2 instrument. Group 5: Preparation with ProTaper Next instruments up to X2 instrument. No procedure was applied to control group. The roots were sectioned horizontally at 3, 6 and 9 mm from the apex and examined. Absence or presence of dentinal microcracks was noted. The Chi-square test was performed to compare the appearance of cracked roots between all groups. There were no significant differences among the groups (P > 0.05). In conclusion, except the hand file and control group, all experimental groups showed microcrack formations.

  9. Applications of Ko Displacement Theory to the Deformed Shape Predictions of the Doubly-Tapered Ikhana Wing

    NASA Technical Reports Server (NTRS)

    Ko, William L.; Richards, W. Lance; Fleischer, Van Tran

    2009-01-01

    The Ko displacement theory, formulated for weak nonuniform (slowly changing cross sections) cantilever beams, was applied to the deformed shape analysis of the doubly-tapered wings of the Ikhana unmanned aircraft. The two-line strain-sensing system (along the wingspan) was used for sensing the bending strains needed for the wing-deformed shapes (deflections and cross-sectional twist) analysis. The deflection equation for each strain-sensing line was expressed in terms of the bending strains evaluated at multiple numbers of strain-sensing stations equally spaced along the strain-sensing line. For the preflight shape analysis of the Ikhana wing, the strain data needed for input to the displacement equations for the shape analysis were obtained from the nodal-stress output of the finite-element analysis. The wing deflections and cross-sectional twist angles calculated from the displacement equations were then compared with those computed from the finite-element computer program. The Ko displacement theory formulated for weak nonlinear cantilever beams was found to be highly accurate in the deformed shape predictions of the doubly-tapered Ikhana wing.

  10. Detection of volatile organic compounds using an optical fiber sensor coated with a sol-gel silica layer containing immobilized Nile red

    NASA Astrophysics Data System (ADS)

    Liu, Dejun; Lian, Xiaokang; Mallik, Arun Kumar; Han, Wei; Wei, Fangfang; Yuan, Jinhui; Yu, Chongxiu; Farrell, Gerald; Semenova, Yuliya; Wu, Qiang

    2017-04-01

    A simple volatile organic compound (VOC) sensor based on a tapered small core singlemode fiber (SCSMF) structure is reported. The tapered SCSMF fiber structure with a waist diameter of 7.0 μm is fabricated using a customized microheater brushing technique. Silica based material containing immobilized Nile red was prepared by a sol-gel method and was used as a coating applied to the surface of the tapered fiber structure. Different coating thicknesses created by a 2-pass and 4-pass coating process are investigated. The experiments demonstrate that both sensors show a linear response at different gas concentrations to all three tested VOCs (methanol, ethanol and acetone). The sensor with a thicker coating shows better sensitivities but longer response and recovery times. The best measurement resolutions for the 4-pass coating sensor are estimated to be 2.3 ppm, 1.5 ppm and 3.1 ppm for methanol, ethanol and acetone, respectively. The fastest response and recovery time of 1 min and 5 min are demonstrated by the sensor in the case of methanol.

  11. High sensitivity refractive index sensor based on a tapered small core single-mode fiber structure.

    PubMed

    Liu, Dejun; Mallik, Arun Kumar; Yuan, Jinhui; Yu, Chongxiu; Farrell, Gerald; Semenova, Yuliya; Wu, Qiang

    2015-09-01

    A high sensitivity refractive index (RI) sensor based on a tapered small core single-mode fiber (SCSMF) structure sandwiched between two traditional single-mode fibers (SMF28) is reported. The microheater brushing technique was employed to fabricate the tapered fiber structures with different waist diameters of 12.5, 15.0, and 18.8 μm. Experiments demonstrate that the fiber sensor with a waist diameter of 12.5 μm offers the best sensitivity of 19212.5  nm/RIU (RI unit) in the RI range of 1.4304 to 1.4320. All sensors fabricated in this Letter show good linearity in terms of the spectral wavelength shift versus changes in RI. Furthermore, the sensor with the best sensitivity to RI was also used to measure relative humidity (RH) without any coating materials applied to the fiber surface. Experimental results show that the spectral wavelength shift changes exponentially as the RH varies from 60% to 95%. A maximum sensitivity of 18.3 nm per relative humidity unit (RHU) was achieved in the RH range of 90.4% to 94.5% RH.

  12. Deprescribing benzodiazepine receptor agonists: Evidence-based clinical practice guideline.

    PubMed

    Pottie, Kevin; Thompson, Wade; Davies, Simon; Grenier, Jean; Sadowski, Cheryl A; Welch, Vivian; Holbrook, Anne; Boyd, Cynthia; Swenson, Robert; Ma, Andy; Farrell, Barbara

    2018-05-01

    To develop an evidence-based guideline to help clinicians make decisions about when and how to safely taper and stop benzodiazepine receptor agonists (BZRAs); to focus on the highest level of evidence available and seek input from primary care professionals in the guideline development, review, and endorsement processes. The overall team comprised 8 clinicians (1 family physician, 2 psychiatrists, 1 clinical psychologist, 1 clinical pharmacologist, 2 clinical pharmacists, and 1 geriatrician) and a methodologist; members disclosed conflicts of interest. For guideline development, a systematic process was used, including the GRADE (Grading of Recommendations Assessment, Development and Evaluation) approach. Evidence was generated by conducting a systematic review of BZRA deprescribing trials for insomnia, as well as performing a review of reviews of the harms of continued BZRA use and narrative syntheses of patient preferences and resource implications. This evidence and GRADE quality of evidence ratings were used to generate recommendations. The team refined guideline content and recommendations through consensus and synthesized clinical considerations to address front-line clinician questions. The draft guideline was reviewed by clinicians and stakeholders. We recommend that deprescribing (tapering slowly) of BZRAs be offered to elderly adults (≥ 65 years) who take BZRAs, regardless of duration of use, and suggest that deprescribing (tapering slowly) be offered to adults aged 18 to 64 who have used BZRAs for more than 4 weeks. These recommendations apply to patients who use BZRAs to treat insomnia on its own (primary insomnia) or comorbid insomnia where potential underlying comorbidities are effectively managed. This guideline does not apply to those with other sleep disorders or untreated anxiety, depression, or other physical or mental health conditions that might be causing or aggravating insomnia. Benzodiazepine receptor agonists are associated with harms, and therapeutic effects might be short term. Tapering BZRAs improves cessation rates compared with usual care without serious harms. Patients might be more amenable to deprescribing conversations if they understand the rationale (potential for harm), are involved in developing the tapering plan, and are offered behavioural advice. This guideline provides recommendations for making decisions about when and how to reduce and stop BZRAs. Recommendations are meant to assist with, not dictate, decision making in conjunction with patients. Copyright© the College of Family Physicians of Canada.

  13. Tapering Practices of Croatian Open-Class Powerlifting Champions.

    PubMed

    Grgic, Jozo; Mikulic, Pavle

    2017-09-01

    Grgic, J and Mikulic, P. Tapering practices of Croatian open-class powerlifting champions. J Strength Cond Res 31(9): 2371-2378, 2017-The aim of this study was to explore tapering practices among 10 Croatian open-class powerlifting champions (mean ± SD: age 29.2 ± 3.2 years; Wilks coefficient 355.1 ± 54.8). The athletes were interviewed about their tapering practices using a semi-structured interview after which the audio content was transcribed. The athletes reported decreasing training volume during the taper by 50.5 ± 11.7% using a step type or an exponential type of taper with a fast decay. Training intensity was maintained or increased during the taper, and it reached its highest values 8 ± 3 days before the competition. Training frequency was reduced or maintained during the taper. The final week included a reduction in training frequency by 47.9 ± 17.5% with the last training session performed 3 ± 1 days before the competition. The participants typically stated that the main reasons for conducting the taper were maintaining strength and reducing the amount of fatigue. They also stated that (a) the taper was structured identically for the squat, bench press, and the deadlift; (b) the training during the taper was highly specific, the assistance exercises were removed, and the same equipment was used as during competition; (c) the source of information for tapering was their coach, and training fluctuated based on the coach's feedback; and (d) nutrition, foam rolling, static stretching, and massage were all given extra attention during the taper. These results may aid athletes and coaches in strength sports in terms of the optimization of tapering variables.

  14. In-situ Tapering of Chalcogenide Fiber for Mid-infrared Supercontinuum Generation

    PubMed Central

    Rudy, Charles W.; Marandi, Alireza; Vodopyanov, Konstantin L.; Byer, Robert L.

    2013-01-01

    Supercontinuum generation (SCG) in a tapered chalcogenide fiber is desirable for broadening mid-infrared (or mid-IR, roughly the 2-20 μm wavelength range) frequency combs1, 2 for applications such as molecular fingerprinting, 3 trace gas detection, 4 laser-driven particle acceleration, 5 and x-ray production via high harmonic generation. 6 Achieving efficient SCG in a tapered optical fiber requires precise control of the group velocity dispersion (GVD) and the temporal properties of the optical pulses at the beginning of the fiber, 7 which depend strongly on the geometry of the taper. 8 Due to variations in the tapering setup and procedure for successive SCG experiments-such as fiber length, tapering environment temperature, or power coupled into the fiber, in-situ spectral monitoring of the SCG is necessary to optimize the output spectrum for a single experiment. In-situ fiber tapering for SCG consists of coupling the pump source through the fiber to be tapered to a spectral measurement device. The fiber is then tapered while the spectral measurement signal is observed in real-time. When the signal reaches its peak, the tapering is stopped. The in-situ tapering procedure allows for generation of a stable, octave-spanning, mid-IR frequency comb from the sub harmonic of a commercially available near-IR frequency comb. 9 This method lowers cost due to the reduction in time and materials required to fabricate an optimal taper with a waist length of only 2 mm. The in-situ tapering technique can be extended to optimizing microstructured optical fiber (MOF) for SCG10 or tuning of the passband of MOFs, 11 optimizing tapered fiber pairs for fused fiber couplers12 and wavelength division multiplexers (WDMs), 13 or modifying dispersion compensation for compression or stretching of optical pulses.14-16 PMID:23748947

  15. Tapering Practices of Strongman Athletes.

    PubMed

    Winwood, Paul W; Dudson, Mike K; Wilson, Daniel; Mclaren-Harrison, Justice K H; Redjkins, Vladislav; Pritchard, Hayden J; Keogh, Justin W L

    2018-05-01

    Winwood, PW, Dudson, MK, Wilson, D, Mclaren-Harrison, JKH, Redjkins, V, Pritchard, HJ, and Keogh, JWL. Tapering practices of strongman athletes. J Strength Cond Res 32(5): 1181-1196, 2018-This study provides the first empirical evidence of how strongman athletes taper for strongman competitions. Strongman athletes (n = 454) (mean ± SD: 33.2 ± 8.0 years, 178.1 ± 10.6 cm, 108.6 ± 27.9 kg, 12.6 ± 8.9 years general resistance training, 5.3 ± 5.0 years strongman implement training) completed a self-reported 4-page internet survey on tapering practices. Analysis by sex (male and female), age (≤30 and >30 years), body mass (≤105 and >105 kg), and competitive standard (local/regional amateur, national amateur and professional) was conducted. Eighty-seven percent (n = 396) of strongman athletes reported that they used a taper. Athletes stated that their typical taper length was 8.6 ± 5.0 days, with the step taper the most commonly performed taper (52%). Training volume decreased during the taper by 45.5 ± 12.9%, and all training ceased 3.9 ± 1.8 days out from competition. Typically, athletes reported that training frequency and training duration stayed the same or decreased and training intensity decreased to around 50% in the last week. Athletes generally stated that tapering was performed to achieve recovery, rest, and peak performance; the deadlift, yoke walk, and stone lifts/work took longer to recover from than other lifts; assistance exercises were reduced or removed in the taper; massage, foam rolling, nutritional changes, and static stretching were strategies used in the taper; and, poor tapering occurred when athletes trained too heavy/hard or had too short a taper. These data will assist strongman athletes and coaches in the optimization of tapering variables leading to more peak performances. Future research could investigate the priming and preactivation strategies strongman athletes use on competition day.

  16. Coupled tapering/uptapering of Thirring type soliton pair in nonlinear media

    NASA Astrophysics Data System (ADS)

    Prasad, Shraddha; Dutta, Manoj Kumar; Sarkar, Ram Krishna

    2018-03-01

    The paper investigates coupled tapering/uptapering of Thirring type soliton pair, employing Beam Propagation Method. It is seen that, the pair uptapers in presence of losses and tapers in presence of gain. When the first beam has gain and the second one has losses in the nonlinear medium, the second beam induces uptapering in the first beam, while, first beam induces tapering in the second beam. When the medium provides gain/losses to only one of the two beams, the beam undergoes tapering/uptapering and also induces tapering/uptapering to the other loss less beam; however, magnitude of tapering/uptapering are different.

  17. Numerical modelling on stimulated Brillouin scattering characterization for Graphene-clad tapered silica fiber

    NASA Astrophysics Data System (ADS)

    Lee, Hui Jing; Abdullah, Fairuz; Ismail, Aiman

    2017-11-01

    This paper presents finite numerical modelling on the cross-sectional region of tapered single mode fiber and graphene-clad tapered fiber. Surface acoustic wave propagation across the tapered surface region on tapered single mode fiber has a high threshold power at 61.87 W which is challenging to overcome by the incident pump wave. Surface acoustic wave propagation of fiber surface however made tapered wave plausible in the optical sensor application. This research introduces graphene as the cladding layer on tapered fiber, acoustic confinement occurs due to the graphene cladding which lowers the threshold power from 61.87 W to 2.17 W.

  18. Buprenorphine tapering schedule and illicit opioid use

    PubMed Central

    Ling, Walter; Hillhouse, Maureen; Domier, Catherine; Doraimani, Geetha; Hunter, Jeremy; Thomas, Christie; Jenkins, Jessica; Hasson, Albert; Annon, Jeffrey; Saxon, Andrew; Selzer, Jeffrey; Boverman, Joshua; Bilangi, Richard

    2011-01-01

    Aims To compare the effects of a short or long taper schedule after buprenorphine stabilization on participant outcomes as measured by opioid-free urine tests at the end of each taper period. Design This multi-site study sponsored by Clinical Trials Network (CTN, a branch of the US National Institute on Drug Abuse) was conducted from 2003 to 2005 to compare two taper conditions (7 days and 28 days). Data were collected at weekly clinic visits to the end of the taper periods, and at 1-month and 3-month post-taper follow-up visits. Setting Eleven out-patient treatment programs in 10 US cities. Intervention Non-blinded dosing with Suboxone® during the 1-month stabilization phase included 3 weeks of flexible dosing as determined appropriate by the study physicians. A fixed dose was required for the final week before beginning the taper phase. Measurements The percentage of participants in each taper group providing urine samples free of illicit opioids at the end of the taper and at follow-up. Findings At the end of the taper, 44% of the 7-day taper group (n = 255) provided opioid-free urine specimens compared to 30% of the 28-day taper group (n = 261; P = 0.0007). There were no differences at the 1-month and 3-month follow-ups (7-day = 18% and 12%; 28-day = 18% and 13%, 1 month and 3 months, respectively). Conclusion For individuals terminating buprenorphine pharmacotherapy for opioid dependence, there appears to be no advantage in prolonging the duration of taper. PMID:19149822

  19. Monitoring the fabrication of tapered optical fibres

    NASA Astrophysics Data System (ADS)

    Mullaney, K.; Correia, R.; Staines, S. E.; James, S. W.; Tatam, R. P.

    2017-04-01

    A variety of optical methods to enhance the process of making optical fibre tapers are explored. A thermal camera was used to both refine the alignment of the optical components and optimize the laser power profile during the tapering process. The fibre transmission was measured to verify that the tapers had the requisite optical characteristics while the strain experienced by the fibre while tapering was assessed using an optical fibre Bragg grating. Using these techniques, adiabatic tapers were fabricated with a 2% insertion loss.

  20. Performance tests with a 4.75 inch bore tapered-roller bearings at high speeds

    NASA Technical Reports Server (NTRS)

    Signer, H. R.; Pinel, S. I.

    1977-01-01

    The tapered-roller bearings were tested at speeds to 15,000 rpm which results in a cone-rib tangential velocity of 130 m/sec. (25,500 ft/min). Lubrication was applied either by jets or directly to the cone-rib, augmented with jets. Additional test parameters included thrust loads to 53,400 N (12,000 lbs), radial loads to 26,700 N (6,000 lbs), lubricant flow rates from 1.9 x 0.000 to 15.1 x 0.001 cubic meter/min. (0.5 to 4.0 gpm), and lubricant inlet temperatures of 350 K and 364 K (170 F and 195 F). Temperature distribution, separator speed, and drive-motor power demand were determined as functions of these test parameters.

  1. Tapered oral dexamethasone for the acute chest syndrome of sickle cell disease.

    PubMed

    Quinn, Charles T; Stuart, Marie J; Kesler, Karen; Ataga, Kenneth I; Wang, Winfred C; Styles, Lori; Smith-Whitley, Kim; Wun, Ted; Raj, Ashok; Hsu, Lewis L; Krishnan, Suba; Kuypers, Frans A; Setty, Yamaja; Rhee, Seungshin; Key, Nigel S; Buchanan, George R

    2011-10-01

    Tapered oral dexamethasone for acute chest syndrome (ACS) in sickle cell anaemia was studied using a novel ACS assessment tool and investigational biomarkers. Twelve participants were randomized (mean age 17·3 years) before early study termination. Dexamethasone decreased duration of hospitalization for ACS by 20·8 h compared to placebo (P = 0·024). Rebound pain occurred in both groups (3 dexamethasone versus 1 placebo). Overall, dexamethasone decreased the leucocyte activation biomarker, sL-selectin; however, participants with rebound pain had higher sL-selectin within 24 h of treatment (dexamethasone or placebo). This ACS assessment tool was feasibly applied, and sL-selectin is a promising biomarker of ACS therapy. © 2011 Blackwell Publishing Ltd.

  2. Wide angle near-field optical probes by reverse tube etching.

    PubMed

    Patanè, S; Cefalì, E; Arena, A; Gucciardi, P G; Allegrini, M

    2006-04-01

    We present a simple modification of the tube etching process for the fabrication of fiber probes for near-field optical microscopy. It increases the taper angle of the probe by a factor of two. The novelty is that the fiber is immersed in hydrofluoric acid and chemically etched in an upside-down geometry. The tip formation occurs inside the micrometer tube cavity formed by the polymeric jacket. By applying this approach, called reverse tube etching, to multimode fibers with 200/250 microm core/cladding diameter, we have fabricated tapered regions featuring high surface smoothness and average cone angles of approximately 30 degrees . A simple model based on the crucial role of the gravity in removing the etching products, explains the tip formation process.

  3. Efficacy of Tramadol Extended-Release for Opioid Withdrawal: A Randomized Clinical Trial.

    PubMed

    Dunn, Kelly E; Tompkins, D Andrew; Bigelow, George E; Strain, Eric C

    2017-09-01

    Opioid use disorder (OUD) is a significant public health problem. Supervised withdrawal (ie, detoxification) from opioids using clonidine or buprenorphine hydrochloride is a widely used treatment. To evaluate whether tramadol hydrochloride extended-release (ER), an approved analgesic with opioid and nonopioid mechanisms of action and low abuse potential, is effective for use in supervised withdrawal settings. A randomized clinical trial was conducted in a residential research setting with 103 participants with OUD. Participants' treatment was stabilized with morphine, 30 mg, administered subcutaneously 4 times daily. A 7-day taper using clonidine (n = 36), tramadol ER (n = 36), or buprenorphine (n = 31) was then instituted, and patients were crossed-over to double-blind placebo during a post-taper period. The study was conducted from October 25, 2010, to June 23, 2015. Retention, withdrawal symptom management, concomitant medication utilization, and naltrexone induction. Results were analyzed over time and using area under the curve for the intention-to-treat and completer groups. Of the 103 participants, 88 (85.4%) were men and 43 (41.7%) were white; mean (SD) age was 28.9 (10.4) years. Buprenorphine participants (28 [90.3%]) were significantly more likely to be retained at the end of the taper compared with clonidine participants (22 [61.1%]); tramadol ER retention was intermediate and did not differ significantly from that of the other groups (26 [72.2%]; χ2 = 8.5, P = .01). Time-course analyses of withdrawal revealed significant effects of phase (taper, post taper) for the Clinical Opiate Withdrawal Scale (COWS) score (taper mean, 5.19 [SE, .26]; post-taper mean, 3.97 [SE, .23]; F2,170 = 3.6, P = .03) and Subjective Opiate Withdrawal Scale (SOWS) score (taper mean,8.81 [SE, .40]; post-taper mean, 4.14 [SE, .30]; F2,170 = 15.7, P < .001), but no group effects or group × phase interactions. Analyses of area under the curve of SOWS total scores showed significant reductions (F2,159 = 17.7, P < .001) in withdrawal severity between the taper and post-taper periods for clonidine (taper mean, 13.1; post-taper mean, 3.2; P < .001) and tramadol ER (taper mean, 7.4; post-taper mean, 2.8; P = .03), but not buprenorphine (taper mean, 6.4; post-taper mean, 7.4). Use of concomitant medication increased significantly (F2,159 = 30.7,  P < .001) from stabilization to taper in the clonidine (stabilization mean, 0.64 [SE, .05]; taper mean, 1.54 [SE, .10]; P < .001) and tramadol ER (stabilization mean, 0.53 [SE, .05]; taper mean, 1.19 [SE, .09]; P = .003) groups and from stabilization to post taper in the buprenorphine group (stabilization mean, 0.46 [SE, .05] post-taper mean, 1.17 [SE, .09]; P = .006), suggesting higher withdrawal for those groups during those periods. Naltrexone initiation was voluntary and the percentage of participants choosing naltrexone therapy within the clonidine (8 [22.2%]), tramadol ER (7 [19.4%]), or buprenorphine (3 [9.7%]) groups did not differ significantly (χ2 = 2.5, P = .29). The results of this trial suggest that tramadol ER is more effective than clonidine and comparable to buprenorphine in reducing opioid withdrawal symptoms during a residential tapering program. Data support further examination of tramadol ER as a method to manage opioid withdrawal symptoms. Clinicaltrials.gov Identifier: NCT01188421.

  4. The influence of simulated clinical use on the flexibility of rotary ProTaper Universal, K3 and EndoSequence nickel-titanium instruments.

    PubMed

    Viana, A C D; Pereira, E S J; Bahia, M G A; Buono, V T L

    2013-09-01

    To investigate the influence of cyclic flexural and torsional loading on the flexibility of ProTaper Universal, K3 and EndoSequence nickel-titanium instruments, in view of the hypothesis that these types of loading would decrease the flexibility of the selected NiTi rotary files. The instruments evaluated were S2 and F1 ProTaper Universal, sizes 20 and 25, .06 taper K3, and sizes 20 and 25, .06 taper EndoSequence. Flexibility was determined by 45° bending tests according to ISO 3630-1 specification. Values of the bending moment (MB ) obtained with new instruments were considered as the control group (CG). Bending tests were then conducted in instruments previously fatigued to one-fourth and three-fourths of their average fatigue life (fatigue groups, FG¼ and FG¾), as well as after cyclic torsional loading (torsional group, TG). Fatigue tests were carried out in a bench device that allowed the files to rotate freely inside an artificial canal with an angle of curvature of 45° and a radius of 5 mm. Cyclic torsional loading tests were performed that entailed rotating the instrument from zero angular deflection to 180° and then returning to zero applied torque in 20 cycles. Data were analysed using one-way analysis of variance at a significance level of 5%. Simulated clinical use by means of flexural fatigue tests did not affect the flexibility of the instruments, except for a significant increase in flexibility observed in a few instruments (P < 0.05). In addition, comparative statistical analyses between the values of MB measured in new instruments and after cyclic torsional loading showed no significant differences between them (P > 0.05). The flexibility of rotary ProTaper Universal, K3 and EndoSequence NiTi instruments, measured in bending tests, was not adversely affected by simulated clinical use in curved root canals. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  5. 2D constant-loss taper for mode conversion

    NASA Astrophysics Data System (ADS)

    Horth, Alexandre; Kashyap, Raman; Quitoriano, Nathaniel J.

    2015-03-01

    Proposed in this manuscript is a novel taper geometry, the constant-loss taper (CLT). This geometry is derived with 1D slabs of silicon embedded in silicon dioxide using coupled-mode theory (CMT). The efficiency of the CLT is compared to both linear and parabolic tapers using CMT and 2D finite-difference time-domain simulations. It is shown that over a short 2D, 4.45 μm long taper the CLT's mode conversion efficiency is ~90% which is 10% and 18% more efficient than a 2D parabolic or linear taper, respectively.

  6. Evaluation of retention and fracture resistance of different fiber reinforced posts: An in vitro study.

    PubMed

    Pruthi, Varun; Talwar, Sangeeta; Nawal, Ruchika Roongta; Pruthi, Preeti Jain; Choudhary, Sarika; Yadav, Seema

    2018-01-01

    The aim of this study was to evaluate retention & fracture resistance of different fibre posts. 90 extracted human permanent maxillary central incisors were used in this study. For retention evaluation, after obturation, post space preparation was done in all root canals and posts were cemented under three groups. Later, the posts were grasped & pulled out from the roots with the help of a three-jaw chuck at a cross-head speed of 5mm/min. Force required to dislodge each post was recorded in Newtons. To evaluate the fracture behavior of posts, artificial root canals were drilled into aluminium blocks and posts were cemented. Load required to fracture each post was recorded in Newtons. The results of the present study show the mean retention values for Fibrekleer Parallel post were significantly greater than those for Synca Double tapered post & Bioloren Tapered post. The mean retention values of the Double tapered post & the tapered post were not statistically different. The Synca Double tapered post had the highest mean load to fracture, and this value was significantly higher than those of FibreKleer Parallel & Bioloren Tapered post. The mean fracture resistance values of Parallel & tapered post were not statistically different. This study showed parallel posts to have better retention than tapered and double tapered posts. Regarding the fracture resistance, double tapered posts were found to be better than parallel and tapered posts.

  7. Tapered fiber nanoprobes: plasmonic nanopillars on tapered optical fiber tips for large EM enhancement.

    PubMed

    Savaliya, Priten; Dhawan, Anuj

    2016-10-01

    Employing finite difference time domain simulations, we demonstrate that electromagnetic field enhancement is substantially greater for tapered optical fibers with plasmonic nanostructures present on their tips as compared with non-tapered optical fibers having those plasmonic nanostructures, or with tapered optical fibers without the plasmonic nanostructures. We also carried out fabrication of plasmonic nanostructures on optical fiber tips.

  8. [Shaping ability of two nickel-titanium rotary systems in simulated S-shaped canals].

    PubMed

    Luo, Hong-xia; Huang, Ding-ming; Zhang, Fu-hua; Tan, Hong; Zhou, Xue-dong

    2008-01-01

    To evaluate the shaping ability of two nickel-titanium rotary systems (ProTaper and Hero642) in simulated S-shaped canals. Thirty simulated S-shaped canals were randomly divided into three groups and prepared by ProTaper, Hero642, ProTaper combined with Hero642 respectively. All the canals were scanned before and after instrumentation, and the amount of material removed in the inner and outer wall and the canal width after instrumentation were measured with a computer image analysis program. There was significant difference in the amount of material removed at the inner side of apical curvature and outer side of apex between ProTaper combined with Hero642 and ProTaper files (P < 0.05) at the same tip size. The inner and outer wall of the canals were evenly prepared by ProTaper combined with Hero642, and the taper of canals were better than those prepared by Hero642. ProTaper combined with Hero 642 had better shaping ability to maintain the original shape and could create good taper canals in the simulated S-shaped canal model.

  9. Octave spanning supercontinuum in an As₂S₃ taper using ultralow pump pulse energy.

    PubMed

    Hudson, Darren D; Dekker, Stephen A; Mägi, Eric C; Judge, Alexander C; Jackson, Stuart D; Li, Enbang; Sanghera, J S; Shaw, L B; Aggarwal, I D; Eggleton, Benjamin J

    2011-04-01

    An octave spanning spectrum is generated in an As₂S₃ taper via 77 pJ pulses from an ultrafast fiber laser. Using a previously developed tapering method, we construct a 1.3 μm taper that has a zero-dispersion wavelength around 1.4 μm. The low two-photon absorption of sulfide-based chalcogenide fiber allows for higher input powers than previous efforts in selenium-based chalcogenide tapered fibers. This higher power handling capability combined with input pulse chirp compensation allows an octave spanning spectrum to be generated directly from the taper using the unamplified laser output.

  10. Comparison of Pressure Changes by Head and Neck Position between High-Volume Low-Pressure and Taper-Shaped Cuffs: A Randomized Controlled Trial

    PubMed Central

    Komasawa, Nobuyasu; Mihara, Ryosuke; Imagawa, Kentaro; Hattori, Kazuo; Minami, Toshiaki

    2015-01-01

    The present study compared changes in cuff pressure by head and neck position between high-volume low-pressure (HVLP) and taper-shaped (taper) cuffs in a prospective randomized clinical trial. Methods. Forty patients were intubated using tracheal tubes with either HVLP (n = 20; HVLP group) or taper-shaped (n = 20; Taper group) cuffs. Initial cuff pressure was adjusted to 15, 20, or 25 cmH2O in the neutral position. Cuff pressure was evaluated after changing the head and neck positions to flexion, extension, and rotation. Results. Cuff pressure significantly increased with flexion in both HVLP and Taper groups at all initial cuff pressures. It significantly increased with extension in the HVLP group, but not in the Taper group. Cuff pressure did not significantly differ with rotation in either group and was significantly smaller in the Taper group during flexion and extension than in the HVLP group, regardless of initial cuff pressure. Conclusion. Cuff pressure changes with head and neck flexion and extension were smaller in the Taper group than in the HVLP group. Our results highlight the potential for taper cuffs to prevent excessive cuff pressure increases with positional changes in the head and neck. This trial is registered with UMIN000016119. PMID:26509152

  11. The Association between Outpatient Buprenorphine Detoxification Duration and Clinical Treatment Outcomes: A Review

    PubMed Central

    Sigmon, Stacey C.; Strain, Eric C.; Heil, Sarah H.; Higgins, Stephen T.

    2011-01-01

    Background The association between buprenorphine taper duration and treatment outcomes is not well understood. This review evaluated whether duration of outpatient buprenorphine taper is significantly associated with treatment outcomes. Methods Studies that were published in peer-reviewed journals, administered buprenorphine as an outpatient taper to opioid-dependent participants, and provided data on at least one of three primary treatment outcome measures (opioid abstinence, retention, peak withdrawal severity) were reviewed. Primary treatment outcomes were evaluated as a function of taper duration using hierarchical linear regressions using pre-taper maintenance as a cofactor. Results Twenty-eight studies were reviewed. Taper duration significantly predicted percent of opioid-negative samples provided during treatment, however pre-taper maintenance period predicted percent participants abstinent on the final day of treatment. High rates of relapse were reported. No significant association between taper duration and retention in treatment or peak withdrawal severity was observed. Conclusion The data reviewed here suggest taper duration is associated with opioid abstinence achieved during detoxification but not with other markers of treatment outcome. The reviewed studies varied widely on several parameters (e.g., frequency of urinalysis testing, provision of ancillary medications) that may influence treatment outcome and thus could have interfered with the ability to identify relationships between taper duration and outcomes. Future studies evaluating opioid detoxification should utilize rigorous experimental methods and report a wider range of outcome measures in order to help advance our understanding of the association between taper duration and treatment outcomes. PMID:21741781

  12. Optimizing treatment with tumour necrosis factor inhibitors in rheumatoid arthritis-a proof of principle and exploratory trial: is dose tapering practical in good responders?

    PubMed

    Ibrahim, Fowzia; Lorente-Cánovas, Beatriz; Doré, Caroline J; Bosworth, Ailsa; Ma, Margaret H; Galloway, James B; Cope, Andrew P; Pande, Ira; Walker, David; Scott, David L

    2017-11-01

    RA patients receiving TNF inhibitors (TNFi) usually maintain their initial doses. The aim of the Optimizing Treatment with Tumour Necrosis Factor Inhibitors in Rheumatoid Arthritis trial was to evaluate whether tapering TNFi doses causes loss of clinical response. We enrolled RA patients receiving etanercept or adalimumab and a DMARD with DAS28 under 3.2 for over 3 months. Initially (months 0-6) patients were randomized to control (constant TNFi) or two experimental groups (tapering TNFi by 33 or 66%). Subsequently (months 6-12) control subjects were randomized to taper TNFi by 33 or 66%. Disease flares (DAS28 increasing ⩾0.6 with at least one additional swollen joint) were the primary outcome. Two hundred and forty-four patients were screened, 103 randomized and 97 treated. In months 0-6 there were 8/50 (16%) flares in controls, 3/26 (12%) with 33% tapering and 6/21 (29%) with 66% tapering. Multivariate Cox analysis showed time to flare was unchanged with 33% tapering but was reduced with 66% tapering compared with controls (adjusted hazard ratio 2.81, 95% CI: 0.99, 7.94; P = 0.051). Analysing all tapered patients after controls were re-randomized (months 6-12) showed differences between groups: there were 6/48 (13%) flares with 33% tapering and 14/39 (36%) with 66% tapering. Multivariate Cox analysis showed 66% tapering reduced time to flare (adjusted hazard ratio 3.47, 95% CI: 1.26, 9.58; P = 0.016). Tapering TNFi by 33% has no impact on disease flares and appears practical in patients in sustained remission and low disease activity states. EudraCT, https://www.clinicaltrialsregister.eu, 2010-020738-24; ISRCTN registry, https://www.isrctn.com, 28955701. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology.

  13. Optimizing treatment with tumour necrosis factor inhibitors in rheumatoid arthritis—a proof of principle and exploratory trial: is dose tapering practical in good responders?

    PubMed Central

    Lorente-Cánovas, Beatriz; Doré, Caroline J; Bosworth, Ailsa; Ma, Margaret H; Galloway, James B; Cope, Andrew P; Pande, Ira; Walker, David; Scott, David L

    2017-01-01

    Abstract Objectives RA patients receiving TNF inhibitors (TNFi) usually maintain their initial doses. The aim of the Optimizing Treatment with Tumour Necrosis Factor Inhibitors in Rheumatoid Arthritis trial was to evaluate whether tapering TNFi doses causes loss of clinical response. Methods We enrolled RA patients receiving etanercept or adalimumab and a DMARD with DAS28 under 3.2 for over 3 months. Initially (months 0–6) patients were randomized to control (constant TNFi) or two experimental groups (tapering TNFi by 33 or 66%). Subsequently (months 6–12) control subjects were randomized to taper TNFi by 33 or 66%. Disease flares (DAS28 increasing ⩾0.6 with at least one additional swollen joint) were the primary outcome. Results Two hundred and forty-four patients were screened, 103 randomized and 97 treated. In months 0–6 there were 8/50 (16%) flares in controls, 3/26 (12%) with 33% tapering and 6/21 (29%) with 66% tapering. Multivariate Cox analysis showed time to flare was unchanged with 33% tapering but was reduced with 66% tapering compared with controls (adjusted hazard ratio 2.81, 95% CI: 0.99, 7.94; P = 0.051). Analysing all tapered patients after controls were re-randomized (months 6–12) showed differences between groups: there were 6/48 (13%) flares with 33% tapering and 14/39 (36%) with 66% tapering. Multivariate Cox analysis showed 66% tapering reduced time to flare (adjusted hazard ratio 3.47, 95% CI: 1.26, 9.58; P = 0.016). Conclusion Tapering TNFi by 33% has no impact on disease flares and appears practical in patients in sustained remission and low disease activity states. Trail registration EudraCT, https://www.clinicaltrialsregister.eu, 2010-020738-24; ISRCTN registry, https://www.isrctn.com, 28955701 PMID:28968858

  14. Refractive index sensors based on the fused tapered special multi-mode fiber

    NASA Astrophysics Data System (ADS)

    Fu, Xing-hu; Xiu, Yan-li; Liu, Qin; Xie, Hai-yang; Yang, Chuan-qing; Zhang, Shun-yang; Fu, Guang-wei; Bi, Wei-hong

    2016-01-01

    In this paper, a novel refractive index (RI) sensor is proposed based on the fused tapered special multi-mode fiber (SMMF). Firstly, a section of SMMF is spliced between two single-mode fibers (SMFs). Then, the SMMF is processed by a fused tapering machine, and a tapered fiber structure is fabricated. Finally, a fused tapered SMMF sensor is obtained for measuring external RI. The RI sensing mechanism of tapered SMMF sensor is analyzed in detail. For different fused tapering lengths, the experimental results show that the RI sensitivity can be up to 444.517 81 nm/RIU in the RI range of 1.334 9—1.347 0. The RI sensitivity is increased with the increase of fused tapering length. Moreover, it has many advantages, including high sensitivity, compact structure, fast response and wide application range. So it can be used to measure the solution concentration in the fields of biochemistry, health care and food processing.

  15. Effect of ripple taper on band-gap overlap in a coaxial Bragg structure operating at terahertz frequency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding Xueyong; Li Hongfan; Lv Zhensu

    Based on the mode-coupling method, numerical analysis is presented to demonstrate the influence of ripple taper on band-gap overlap in a coaxial Bragg structure operating at terahertz frequency. Results show that the interval between the band-gaps of the competing mode and the desired working mode is narrowed by use of positive-taper ripples, but is expanded if negative-taper ripples are employed, and the influence of the negative-taper ripples is obviously more advantageous than the positive-taper ripples; the band-gap overlap of modes can be efficiently separated by use of negative-taper ripples. The residual side-lobes of the frequency response in a coaxial Braggmore » structure with ripple taper also can be effectively suppressed by employing the windowing-function technique. These peculiarities provide potential advantage in constructing a coaxial Bragg cavity with high quality factor for single higher-order-mode operation of a high-power free-electron maser in the terahertz frequency range.« less

  16. IN VIVO SEVERE CORROSION AND HYDROGEN EMBRITTLEMENT OF RETRIEVED MODULAR BODY TITANIUM ALLOY HIP-IMPLANTS

    PubMed Central

    Rodrigues, Danieli C.; Urban, Robert M.; Jacobs, Joshua J.; Gilbert, Jeremy L.

    2009-01-01

    Titanium alloys are widely used in total-joint replacements due to a combination of outstanding mechanical properties, biocompatibility, passivity and corrosion resistance. Nevertheless, retrieval studies have pointed out that these materials can be subjected to localized or general corrosion in modular interfaces when mechanical abrasion of the oxide film (fretting) occurs. Modularity adds large crevice environments, which are subject to micromotion between contacting interfaces and differential aeration of the surface. Titanium alloys are also known to be susceptible to hydrogen absorption, which can induce precipitation of hydrides and subsequent brittle failure. In this work, the surface of three designs of retrieved hip-implants with Ti-6Al-4V/Ti-6Al-4V modular taper interfaces in the stem were investigated for evidence of severe corrosion and precipitation of brittle hydrides during fretting-crevice corrosion in the modular connections. The devices were retrieved from patients and studied by means of scanning electron microscopy (SEM), x-ray diffraction (XRD) and chemical analysis. The surface qualitative investigation revealed severe corrosion attack in the mating interfaces with evidence of etching, pitting, delamination and surface cracking. In vivo hydrogen embrittlement was shown to be a mechanism of degradation in modular connections resulting from electrochemical reactions induced in the crevice environment of the tapers during fretting-crevice corrosion. PMID:18683224

  17. Photonic generation of ultra-wide-band doublet pulse through monolithic integration of tapered directional coupler and quantum well waveguide.

    PubMed

    Kuo, Yu-Zheng; Wu, Jui-Pin; Wu, Tsu-Hsiu; Chiu, Yi-Jen

    2012-10-22

    We proposed and demonstrated a novel scheme of photonic ultra-wide-band (UWB) doublet pulse based on monolithic integration of tapered optical-direction coupler (TODC) and multiple-quantum-well (MQW) waveguide. TODC is formed by a top tapered MQW waveguide vertically integrating with an underneath passive waveguide. Through simultaneous field-driven optical index- and absorption- change in MQW, the partial optical coupling in TODC can be used to get a valley-shaped of optical transmission against voltage. Therefore, doublet-enveloped optical pulse can be realized by high-speed and high-efficient conversion of input electrical pulse. By just adjusting bias through MQW, 1530 nm photonic UWB doublet optical pulse with 75-ps pulse width, below -41.3 dBm power, 125% fractional bandwidth, and 7.5 GHz of -10 dB bandwidth has been demonstrated, fitted into FCC requirement (3.1 GHz~10.6 GHz). Doublet-pulse data transmission generated in optical fiber is also performed for further characterization, exhibiting a successful 1.25 Gb/s error-free transmission. It suggests such optoelectronic integration template can be applied for photonic UWB generation in fiber-based communications.

  18. Lateral bending of tapered piezo-semiconductive nanostructures for ultra-sensitive mechanical force to voltage conversion.

    PubMed

    Araneo, Rodolfo; Falconi, Christian

    2013-07-05

    Quasi-1D piezoelectric nanostructures may offer unprecedented sensitivity for transducing minuscule input mechanical forces into high output voltages due to both scaling laws and increased piezoelectric coefficients. However, until now both theoretical and experimental studies have suggested that, for a given mechanical force, lateral bending of piezoelectric nanowires results in lower output electric potentials than vertical compression. Here we demonstrate that this result only applies to nanostructures with a constant cross-section. Moreover, though it is commonly believed that the output electric potential of a strained piezo-semiconductive device can only be reduced by the presence of free charges, we show that the output piezopotential of laterally bent tapered nanostructures, with typical doping levels and very small input forces, can be even increased up to two times by free charges.Our analyses confirm that, though not optimal for piezoelectric energy harvesting, lateral bending of tapered nanostructures with typical doping levels can be ideal for transducing tiny input mechanical forces into high and accessible piezopotentials. Our results provide guidelines for designing high-performance piezo-nano-devices for energy harvesting, mechanical sensing, piezotronics, piezo-phototronics, and piezo-controlled chemical reactions, among others.

  19. Efficient fiber-coupled single-photon source based on quantum dots in a photonic-crystal waveguide

    PubMed Central

    DAVEAU, RAPHAËL S.; BALRAM, KRISHNA C.; PREGNOLATO, TOMMASO; LIU, JIN; LEE, EUN H.; SONG, JIN D.; VERMA, VARUN; MIRIN, RICHARD; NAM, SAE WOO; MIDOLO, LEONARDO; STOBBE, SØREN; SRINIVASAN, KARTIK; LODAHL, PETER

    2017-01-01

    Many photonic quantum information processing applications would benefit from a high brightness, fiber-coupled source of triggered single photons. Here, we present a fiber-coupled photonic-crystal waveguide single-photon source relying on evanescent coupling of the light field from a tapered out-coupler to an optical fiber. A two-step approach is taken where the performance of the tapered out-coupler is recorded first on an independent device containing an on-chip reflector. Reflection measurements establish that the chip-to-fiber coupling efficiency exceeds 80 %. The detailed characterization of a high-efficiency photonic-crystal waveguide extended with a tapered out-coupling section is then performed. The corresponding overall single-photon source efficiency is 10.9 % ± 2.3 %, which quantifies the success probability to prepare an exciton in the quantum dot, couple it out as a photon in the waveguide, and subsequently transfer it to the fiber. The applied out-coupling method is robust, stable over time, and broadband over several tens of nanometers, which makes it a highly promising pathway to increase the efficiency and reliability of planar chip-based single-photon sources. PMID:28584859

  20. Magnetic Field Sensing Based on Bi-Tapered Optical Fibers Using Spectral Phase Analysis.

    PubMed

    Herrera-Piad, Luis A; Haus, Joseph W; Jauregui-Vazquez, Daniel; Sierra-Hernandez, Juan M; Estudillo-Ayala, Julian M; Lopez-Dieguez, Yanelis; Rojas-Laguna, Roberto

    2017-10-20

    A compact, magnetic field sensor system based on a short, bi-tapered optical fiber (BTOF) span lying on a magnetic tape was designed, fabricated, and characterized. We monitored the transmission spectrum from a broadband light source, which displayed a strong interference signal. After data collection, we applied a phase analysis of the interference optical spectrum. We here report the results on two fabricated, BTOFs with different interference spectrum characteristics; we analyzed the signal based on the interference between a high-order modal component and the core fiber mode. The sensor exhibited a linear response for magnetic field increments, and we achieved a phase sensitivity of around 0.28 rad/mT. The sensing setup presented remote sensing operation and low-cost transducer magnetic material.

  1. Magnetic Field Sensing Based on Bi-Tapered Optical Fibers Using Spectral Phase Analysis

    PubMed Central

    Herrera-Piad, Luis A.; Jauregui-Vazquez, Daniel; Sierra-Hernandez, Juan M.; Lopez-Dieguez, Yanelis

    2017-01-01

    A compact, magnetic field sensor system based on a short, bi-tapered optical fiber (BTOF) span lying on a magnetic tape was designed, fabricated, and characterized. We monitored the transmission spectrum from a broadband light source, which displayed a strong interference signal. After data collection, we applied a phase analysis of the interference optical spectrum. We here report the results on two fabricated, BTOFs with different interference spectrum characteristics; we analyzed the signal based on the interference between a high-order modal component and the core fiber mode. The sensor exhibited a linear response for magnetic field increments, and we achieved a phase sensitivity of around 0.28 rad/mT. The sensing setup presented remote sensing operation and low-cost transducer magnetic material. PMID:29053570

  2. Transverse load sensor based on Mach-Zehnder interferometer constructed by a bowknot type taper

    NASA Astrophysics Data System (ADS)

    Lou, Weimin; Shentu, Fengying; Wang, Youqing; Shen, Changyu; Dong, Xinyong

    2018-01-01

    A transverse load fiber sensor based on Mach-Zehnder interferometer constructed by a Bowknot-type taper between a single mode fiber (SMF) and a polarization maintaining fiber (PMF) was proposed. Due to the polarization maintaining fiber's birefringence, intensities of the two peaks which are corresponding to the fast and slow axis modes changed with the transverse load applied on the PMF. The experimental results showed that the structure with a 2 cm-long PMF has the sensitivities of 104.52 and -102.94 dB/(N/mm) for the fast and slow axis spectral dip wavelengths of 1485 and 1545 nm in the interference pattern, respectively, which are almost 7 times higher than that of the current similar existing transverse load sensor.

  3. Effect of platform connection and abutment material on stress distribution in single anterior implant-supported restorations: a nonlinear 3-dimensional finite element analysis.

    PubMed

    Carvalho, Marco Aurélio; Sotto-Maior, Bruno Salles; Del Bel Cury, Altair Antoninha; Pessanha Henriques, Guilherme Elias

    2014-11-01

    Although various abutment connections and materials have recently been introduced, insufficient data exist regarding the effect of stress distribution on their mechanical performance. The purpose of this study was to investigate the effect of different abutment materials and platform connections on stress distribution in single anterior implant-supported restorations with the finite element method. Nine experimental groups were modeled from the combination of 3 platform connections (external hexagon, internal hexagon, and Morse tapered) and 3 abutment materials (titanium, zirconia, and hybrid) as follows: external hexagon-titanium, external hexagon-zirconia, external hexagon-hybrid, internal hexagon-titanium, internal hexagon-zirconia, internal hexagon-hybrid, Morse tapered-titanium, Morse tapered-zirconia, and Morse tapered-hybrid. Finite element models consisted of a 4×13-mm implant, anatomic abutment, and lithium disilicate central incisor crown cemented over the abutment. The 49 N occlusal loading was applied in 6 steps to simulate the incisal guidance. Equivalent von Mises stress (σvM) was used for both the qualitative and quantitative evaluation of the implant and abutment in all the groups and the maximum (σmax) and minimum (σmin) principal stresses for the numerical comparison of the zirconia parts. The highest abutment σvM occurred in the Morse-tapered groups and the lowest in the external hexagon-hybrid, internal hexagon-titanium, and internal hexagon-hybrid groups. The σmax and σmin values were lower in the hybrid groups than in the zirconia groups. The stress distribution concentrated in the abutment-implant interface in all the groups, regardless of the platform connection or abutment material. The platform connection influenced the stress on abutments more than the abutment material. The stress values for implants were similar among different platform connections, but greater stress concentrations were observed in internal connections. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  4. Fracture resistance of structurally compromised and normal endodontically treated teeth restored with different post systems: An in vitro study

    PubMed Central

    Mortazavi, Vajihesadat; Fathi, Mohammadhossein; Katiraei, Najmeh; Shahnaseri, Shirin; Badrian, Hamid; Khalighinejad, Navid

    2012-01-01

    Background: With the aim of developing methods that could increase the fracture resistance of structurally compromised endodontically treated teeth, this study was conducted to compare the effect of three esthetic post systems on the fracture resistance and failure modes of structurally compromised and normal roots. Materials and Methods: Forty five extracted and endodontically treated maxillary central teeth were assigned to 5 experimental groups (n=9). In two groups, the post spaces were prepared with the corresponding drills of the post systems to be restored with double taper light posts (DT.Light-Post) (group DT.N) and zirconia posts (Cosmopost) (group Zr.N). In other 3 groups thin wall canals were simulated to be restored with Double taper Light posts (DT.W), double taper Light posts and Ribbond fibers (DT+R.W) and Zirconia posts (Zr.W). After access cavity restoration and thermocycling, compressive load was applied and the fracture strength values and failure modes were evaluated. Data were analyzed using two-way ANOVA, Tukey and Fisher exact tests (P<0.05). Results: The mean failure loads (N) were 678.56, 638.22, 732.44, 603.44 and 573.67 for groups DT.N, Zr.N, DT.W, DT+R.W and Zr.w respectively. Group DT+R.W exhibited significantly higher resistance to fracture compared to groups Zr.N, DT.W and Zr.w (P<0.05). A significant difference was detected between groups DT.N and Zr.W (P=0.027). Zirconia posts showed significantly higher root fracture compared to fiber posts (P=0.004). Conclusion: The structurally compromised teeth restored with double taper light posts and Ribbond fibers showed the most fracture resistance and their strengths were comparable to those of normal roots restored with double taper light posts. More desirable fracture patterns were observed in teeth restored with fiber posts. PMID:22623936

  5. Comparative evaluation of apically extruded debris with V-Taper, ProTaper Next, and the Self-adjusting File systems.

    PubMed

    Vyavahare, Nishant K; Raghavendra, Srinidhi Surya; Desai, Niranjan N

    2016-01-01

    Complete cleaning of the root canal is the goal for ensuring success in endodontics. Removal of debris plays an important role in achieving this goal. In spite of advancements in instrument design, apical extrusion of debris remains a source of inflammation in the periradicular region. To comparatively evaluate the amount of apically extruded debris with V-Taper, ProTaper Next, and the self-adjusting File (SAF) system. Sixty-four extracted human mandibular teeth with straight root canals were taken. Access openings were done and working length determined. The samples were randomly divided into three groups: Group I - V-Taper files (n = 20), Group II - ProTaper Next (n = 20), Group III - SAF (n = 20). Biomechanical preparation was completed and the debris collected in vials to be quantitatively determined. The data obtained was statistically analyzed using ANOVA and post hoc Tukey's test. All the specimens showed apical debris extrusion. SAF showed significantly less debris extrusion compared to V-Taper and ProTaper Next (P < 0.001). Among Groups I and II, ProTaper Next showed lesser debris extrusion as compared to V-Taper, but it was not significant (P = 0.124). The SAF showed least amount of apical debris extrusion when compared to newer rotary endodontic instruments. This indicates that the incidence of inter-treatment flare-ups due to debris extrusion would be less with the SAF.

  6. Effect of reciprocating file motion on microcrack formation in root canals: an SEM study.

    PubMed

    Ashwinkumar, V; Krithikadatta, J; Surendran, S; Velmurugan, N

    2014-07-01

    To compare dentinal microcrack formation whilst using Ni-Ti hand K-files, ProTaper hand and rotary files and the WaveOne reciprocating file. One hundred and fifty mandibular first molars were selected. Thirty teeth were left unprepared and served as controls, and the remaining 120 teeth were divided into four groups. Ni-Ti hand K-files, ProTaper hand files, ProTaper rotary files and WaveOne Primary reciprocating files were used to prepare the mesial canals. Roots were then sectioned 3, 6 and 9 mm from the apex, and the cut surface was observed under scanning electron microscope (SEM) and checked for the presence of dentinal microcracks. The control and Ni-Ti hand K-files groups were not associated with microcracks. In roots prepared with ProTaper hand files, ProTaper rotary files and WaveOne Primary reciprocating files, dentinal microcracks were present. There was a significant difference between control/Ni-Ti hand K-files group and ProTaper hand files/ProTaper rotary files/WaveOne Primary reciprocating file group (P < 0.001) with ProTaper rotary files producing the most microcracks. No significant difference was observed between teeth prepared with ProTaper hand files and WaveOne Primary reciprocating files. ProTaper rotary files were associated with significantly more microcracks than ProTaper hand files and WaveOne Primary reciprocating files. Ni-Ti hand K-files did not produce microcracks at any levels inside the root canals. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  7. Hierarchical structures of cactus spines that aid in the directional movement of dew droplets.

    PubMed

    Malik, F T; Clement, R M; Gethin, D T; Kiernan, M; Goral, T; Griffiths, P; Beynon, D; Parker, A R

    2016-08-06

    Three species of cactus whose spines act as dew harvesters were chosen for this study: Copiapoa cinerea var. haseltoniana, Mammillaria columbiana subsp. yucatanensis and Parodia mammulosa and compared with Ferocactus wislizenii whose spines do not perform as dew harvesters. Time-lapse snapshots of C. cinerea showed movement of dew droplets from spine tips to their base, even against gravity. Spines emanating from one of the areoles of C. cinerea were submerged in water laced with fluorescent nanoparticles and this particular areole with its spines and a small area of stem was removed and imaged. These images clearly showed that fluorescent water had moved into the stem of the plant. Lines of vascular bundles radiating inwards from the surface areoles (from where the spines emanate) to the core of the stem were detected using magnetic resonance imaging, with the exception of F. wislizenii that does not harvest dew on its spines. Spine microstructures were examined using SEM images and surface roughness measurements (Ra and Rz) taken of the spines of C. cinerea It was found that a roughness gradient created by tapered microgrooves existed that could potentially direct surface water from a spine tip to its base.This article is part of the themed issue 'Bioinspired hierarchically structured surfaces for green science'. © 2016 The Author(s).

  8. Hierarchical structures of cactus spines that aid in the directional movement of dew droplets

    PubMed Central

    Clement, R. M.; Gethin, D. T.; Kiernan, M.; Goral, T.; Griffiths, P.; Beynon, D.; Parker, A. R.

    2016-01-01

    Three species of cactus whose spines act as dew harvesters were chosen for this study: Copiapoa cinerea var. haseltoniana, Mammillaria columbiana subsp. yucatanensis and Parodia mammulosa and compared with Ferocactus wislizenii whose spines do not perform as dew harvesters. Time-lapse snapshots of C. cinerea showed movement of dew droplets from spine tips to their base, even against gravity. Spines emanating from one of the areoles of C. cinerea were submerged in water laced with fluorescent nanoparticles and this particular areole with its spines and a small area of stem was removed and imaged. These images clearly showed that fluorescent water had moved into the stem of the plant. Lines of vascular bundles radiating inwards from the surface areoles (from where the spines emanate) to the core of the stem were detected using magnetic resonance imaging, with the exception of F. wislizenii that does not harvest dew on its spines. Spine microstructures were examined using SEM images and surface roughness measurements (Ra and Rz) taken of the spines of C. cinerea. It was found that a roughness gradient created by tapered microgrooves existed that could potentially direct surface water from a spine tip to its base. This article is part of the themed issue ‘Bioinspired hierarchically structured surfaces for green science’. PMID:27354735

  9. Influence of temperature gradients on charge transport in asymmetric nanochannels.

    PubMed

    Benneker, Anne M; Wendt, Hans David; Lammertink, Rob G H; Wood, Jeffery A

    2017-10-25

    Charge selective asymmetric nanochannels are used for a variety of applications, such as nanofluidic sensing devices and energy conversion applications. In this paper, we numerically investigate the influence of an applied temperature difference over tapered nanochannels on the resulting charge transport and flow behavior. Using a temperature-dependent formulation of the coupled Poisson-Nernst-Planck and Navier-Stokes equations, various nanochannel geometries are investigated. Temperature has a large influence on the total ion transport, as the diffusivity of ions and viscosity of the solution are strongly affected by temperature. We find that the selectivity of the nanochannels is enhanced with increasing asymmetry ratios, while the total current is reduced at higher asymmetry cases. Most interestingly, we find that applying a temperature gradient along the electric field and along the asymmetry direction of the nanochannel enhances the selectivity of the tapered channels even further, while a temperature gradient countering the electric field reduces the selectivity of the nanochannel. Current rectification is enhanced in asymmetric nanochannels if a temperature gradient is applied, independent of the direction of the temperature difference. However, the degree of rectification is dependent on the direction of the temperature gradient with respect to the channel geometry and the electric field direction. The enhanced selectivity of nanochannels due to applied temperature gradients could result in more efficient operation in energy harvesting or desalination applications, motivating experimental investigations.

  10. Therma motor

    DOEpatents

    Kandarian, R.

    The disclosure is directed to a thermal motor utilizing two tapered prestressed parallel adjacent cylinders lengthwise disposed about one third in a coolant. Heat is applied to contacting portions of the cylinders outside the coolant to cause them to deform and turn. Heat sources such as industrial waste heat, geothermal hot water, solar radiation, etc. can be used.

  11. A novel platform for in vitro analysis of torque, forces, and three-dimensional file displacements during root canal preparations: application to ProTaper rotary files.

    PubMed

    Diop, Amadou; Maurel, Nathalie; Oiknine, Michel; Patoor, Etienne; Machtou, Pierre

    2009-04-01

    We proposed a new testing setup and in vitro experimental procedure allowing the analysis of the forces, torque, and file displacements during the preparation of root canals using nickel-titanium rotary endodontic files. We applied it to the preparation of 20 fresh frozen cadaveric teeth using ProTaper files (Dentsply Maillefer, Ballaigues, Switzerland), according to a clinically used sequence. During the preparations, a clinical hand motion was performed by an endodontist, and we measured the applied torque around the file axis and also the involved three-dimensional forces and 3-dimensional file displacements. Such a biomechanical procedure is useful to better understand the working conditions of the files in terms of loads and displacements. It could be used to analyze the effects of various mechanical and geometric parameters on the files' behavior and to get data for modelling purposes. Finally, it could contribute to studies aiming to improve files design in order to reduce the risks of file fractures.

  12. Design of organic 3D microresonators with microfluidics coupled to thin-film processes for photonic applications

    NASA Astrophysics Data System (ADS)

    Huby, N.; Pluchon, D.; Coulon, N.; Belloul, M.; Moreac, A.; Gaviot, E.; Panizza, P.; Bêche, B.

    2010-06-01

    We report on the design and realization of photonic integrated devices based on 3D organic microresonators (MR) shaped by an applied fluid mechanism technique. Such an interdisciplinary approach has been judiciously achieved by combining microfluidics techniques and thin-film processes, respectively, for the realizations of microfluidic and optical chips. The microfluidic framework with flow rates control allows the fabrication of microresonators with diameters ranging from 30 to 160 μm. The resonance of an isolated sphere in air has been demonstrated by way of a modified Raman spectroscopy devoted to the excitation of Whispering Gallery Modes (WGM). Then the 3D-MR have been integrated onto an organic chip and positioned either close to the extremity of a taper or alongside a rib waveguide. Both devices have proved efficient evanescent coupling mechanisms leading to the excitation of the WGM confined at the surface of the organic 3D-MR. Finally, a band-stop filter has been used to detect the resonance spectra of organic resonators once being integrated. Such spectral resonances have been observed with an integrated configuration and characterized with a Δ λ = 1.4 nm free spectral range (FSR), appearing as stemming from a 78 μm-radius MR structure.

  13. In-line optical fiber sensors based on cladded multimode tapered fibers.

    PubMed

    Villatoro, Joel; Monzón-Hernández, David; Luna-Moreno, Donato

    2004-11-10

    The use of uniform-waist cladded multimode tapered optical fibers is demonstrated for evanescent wave spectroscopy and sensors. The tapering is a simple, low-loss process and consists of stretching the fiber while it is being heated with an oscillating flame torch. As examples, a refractive-index sensor and a hydrogen sensor are demonstrated by use of a conventional graded-index multimode optical fiber. Also, absorbance spectra are measured while the tapers are immersed in an absorbing liquid. It is found experimentally that the uniform waist is the part of the taper that contributes most to the sensor sensitivity. The taper waist diameter may also be used to adjust the sensor dynamic range.

  14. Tapered enlarged ends in multimode optical fibers.

    PubMed

    Brenci, M; Falciai, R; Scheggi, A M

    1982-01-15

    Radiation characteristics of multimode fibers with enlarged tapers were investigated on a number of samples obtained by varying the fiber drawing speed with a given law corresponding to a prefixed taper profile. The characterization of the fibers was made by near- and far-field intensity pattern measurements as well as by measuring the losses introduced by the taper. With a suitable choice of parameters the taper constitutes a reasonable low-loss component useful, for example, for either efficient coupling to large-spot high-power density sources or connecting fibers of different sizes. Conversely at the exit of the fiber the taper can be used for beam shaping which is of interest for mechanical or surgical applications.

  15. Opioid withdrawal, craving, and use during and after outpatient buprenorphine stabilization and taper: A discrete survival and growth mixture model

    PubMed Central

    Stotts, Angela L.; Green, Charles; Potter, Jennifer S.; Marino, Elise N.; Walker, Robrina; Weiss, Roger D.; Trivedi, Madhukar

    2014-01-01

    Most patients relapse to opioids within one month of opioid agonist detoxification, making the antecedents and parallel processes of first use critical for investigation. Craving and withdrawal are often studied in relationship to opioid outcomes, and a novel analytic strategy applied to these two phenomena may indicate targeted intervention strategies. Specifically, this secondary data analysis of the Prescription Opioid Addiction Treatment Study used a discrete-time mixture analysis with time-to-first opioid use (survival) simultaneously predicted by craving and withdrawal growth trajectories. This analysis characterized heterogeneity among prescription opioid-dependent individuals (N=653) into latent classes (i.e., latent class analysis [LCA]) during and after buprenorphine/naloxone stabilization and taper. A 4-latent class solution was selected for overall model fit and clinical parsimony. In order of shortest to longest time-to-first use, the 4 classes were characterized as 1) high craving and withdrawal 2) intermediate craving and withdrawal 3) high initial craving with low craving and withdrawal trajectories and 4) a low initial craving with low craving and withdrawal trajectories. Odds ratio calculations showed statistically significant differences in time-to-first use across classes. Generally, participants with lower baseline levels and greater decreases in craving and withdrawal during stabilization combined with slower craving and withdrawal rebound during buprenorphine taper remained opioid-free longer. This exploratory work expanded on the importance of monitoring craving and withdrawal during buprenorphine induction, stabilization, and taper. Future research may allow individually tailored and timely interventions to be developed to extend time-to-first opioid use. PMID:25282598

  16. Peak insertion torque values of five mini-implant systems under different insertion loads.

    PubMed

    Quraishi, Erma; Sherriff, Martyn; Bister, Dirk

    2014-06-01

    To assess the effect of 1 and 3 kg insertion load on five makes of self-drilling mini-implants on peak insertion torque values to establish risk factors involved in the fracture of mini-implants. Two different loads were applied during insertion of 40 mini-implants from five different manufacturers (Dual Top(™) (1·6×8 mm), Infinitas(™) (1·5×9 mm), Ortho Easy(™) (1·7×8 mm), Spider Screw(™) (1·5×8 mm) and Vector TAS(™) (1·4×8 mm)) into acrylic blocks at 8 rev/min utilizing a Motorized Torque Measurement Stand. Peak insertion torque values for both loads were highest for Vector TAS followed by Ortho Easy and Dual Top and were nearly three times higher than Infinitas (original version) and Spider Screws(TM). The log-rank test showed statistically significant differences for both loads for Vector TAS, Ortho Easy and Spider Screws. Unlike other designs tested, both tapered mini-implant designs (Spider Screw and Infinitas) showed a tendency to buckle in the middle of the body but fractured at the tip. Non-tapered mini-implants fractured at significantly higher torque values compared to tapered designs under both loads. Increased pressure resulted in slightly higher maximum torque values at fracture for some of the mini-implant designs, although this is unlikely to be of clinical relevance. Tripling insertion pressure from 1 to 3 kg increased the risk of bending tapered mini-implants before fracture. © 2014 British Orthodontic Society.

  17. 77 FR 45588 - Tapered Roller Bearings and Parts Thereof, Finished and Unfinished, From the People's Republic of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-01

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-601] Tapered Roller Bearings and... new shipper review (``NSR'') of the antidumping duty order on tapered roller bearings from the People... The notice announcing the antidumping duty order on tapered roller bearings from the PRC was published...

  18. 76 FR 6397 - Tapered Roller Bearings and Parts Thereof, Finished and Unfinished From the People's Republic of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-04

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-601] Tapered Roller Bearings and... on tapered roller bearings (``TRBs'') from the People's Republic of China (``PRC'') meets the... published in the Federal Register on June 15, 1987. See Antidumping Duty Order; Tapered Roller Bearings and...

  19. 76 FR 45777 - Tapered Roller Bearings and Parts Thereof, Finished and Unfinished From the People's Republic of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-01

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-601] Tapered Roller Bearings and... tapered roller bearings (``TRBs'') from the People's Republic of China (``PRC'') meets the statutory and... Register on June 15, 1987. See Antidumping Duty Order; Tapered Roller Bearings and Parts Thereof, Finished...

  20. Simple Expressions for the Design of Linear Tapers in Overmoded Corrugated Waveguides

    DOE PAGES

    Schaub, S. C.; Shapiro, M. A.; Temkin, R. J.

    2015-08-16

    In this paper, simple analytical formulae are presented for the design of linear tapers with very low mode conversion loss in overmoded corrugated waveguides. For tapers from waveguide radius a2 to a1, with a11a 2/λ. Here, λ is the wavelength of radiation. The fractional loss of the HE 11 mode in an optimized taper is 0.0293(a 2-a 1) 4/amore » $$2\\atop{1}$$1a$$2\\atop{2}$$. These formulae are accurate when a2≲2a 1. Slightly more complex formulae, accurate for a 2≤4a 1, are also presented in this paper. The loss in an overmoded corrugated linear taper is less than 1 % when a 2≤2.12a 1 and less than 0.1 % when a 2≤1.53a 1. The present analytic results have been benchmarked against a rigorous mode matching code and have been found to be very accurate. The results for linear tapers are compared with the analogous expressions for parabolic tapers. Finally, parabolic tapers may provide lower loss, but linear tapers with moderate values of a 2/a 1 may be attractive because of their simplicity of fabrication.« less

  1. Enhancing sensitivity of biconical tapered fiber sensors with multiple passes through the taper

    NASA Astrophysics Data System (ADS)

    Cohoon, Gregory; Boyter, Chris; Errico, Michael; Vandervoort, Kurt; Salik, Ertan

    2010-03-01

    A single biconical fiber taper is a simple and low-cost yet powerful sensor. With a distinct strength in refractive index (RI) sensing, biconical tapered fiber sensors can find their place in handheld sensor platforms, especially as biosensors that are greatly needed in health care, environmental protection, food safety, and biodefense. We report doubling of sensitivity for these sensors with two passes through the tapered region, which becomes possible through the use of sensitive and high-dynamic-range photodetectors. In a proof-of-principle experiment, we measured transmission through the taper when it was immersed in isopropyl alcohol-water mixtures of varying concentrations, in which a thin gold layer at the tip of the fiber acted as a mirror enabling two passes through the tapered region. This improved the sensitivity from 0.43 dB/vol % in the single-pass case to 0.78 dB/vol % with two passes through the taper. The refractive index detection limit was estimated to be ~1.2×10-5 RI units (RIU) and ~0.6×10-5 RIU in the single- and double-pass schemes, respectively. We predict that further enhancement of sensitivity may be achieved with a higher number of passes through the taper.

  2. Comparative evaluation of apically extruded debris with V-Taper, ProTaper Next, and the Self-adjusting File systems

    PubMed Central

    Vyavahare, Nishant K.; Raghavendra, Srinidhi Surya; Desai, Niranjan N.

    2016-01-01

    Background: Complete cleaning of the root canal is the goal for ensuring success in endodontics. Removal of debris plays an important role in achieving this goal. In spite of advancements in instrument design, apical extrusion of debris remains a source of inflammation in the periradicular region. Aim: To comparatively evaluate the amount of apically extruded debris with V-Taper, ProTaper Next, and the self-adjusting File (SAF) system. Materials and Methods: Sixty-four extracted human mandibular teeth with straight root canals were taken. Access openings were done and working length determined. The samples were randomly divided into three groups: Group I - V-Taper files (n = 20), Group II - ProTaper Next (n = 20), Group III - SAF (n = 20). Biomechanical preparation was completed and the debris collected in vials to be quantitatively determined. The data obtained was statistically analyzed using ANOVA and post hoc Tukey's test. Results: All the specimens showed apical debris extrusion. SAF showed significantly less debris extrusion compared to V-Taper and ProTaper Next (P < 0.001). Among Groups I and II, ProTaper Next showed lesser debris extrusion as compared to V-Taper, but it was not significant (P = 0.124). Conclusion: The SAF showed least amount of apical debris extrusion when compared to newer rotary endodontic instruments. This indicates that the incidence of inter-treatment flare-ups due to debris extrusion would be less with the SAF. PMID:27217636

  3. Endodontic shaping performance using nickel-titanium hand and motor ProTaper systems by novice dental students.

    PubMed

    Tu, Ming-Gene; Chen, San-Yue; Huang, Heng-Li; Tsai, Chi-Cheng

    2008-05-01

    Preparing a continuous tapering conical shape and maintaining the original shape of a canal are obligatory in root canal preparation. The purpose of this study was to compare the shaping performance in simulated curved canal resin blocks of the same novice dental students using hand-prepared and engine-driven nickel-titanium (NiTi) rotary ProTaper instruments in an endodontic laboratory class. Twenty-three fourth-year dental students attending China Medical University Dental School prepared 46 simulated curved canals in resin blocks with two types of NiTi rotary systems: hand and motor ProTaper files. Composite images were prepared for estimation. Material removed, canal width and canal deviation were measured at five levels in the apical 4 mm of the simulated curved canals using AutoCAD 2004 software. Data were analyzed using Wilcoxon's rank-sum test. The hand ProTaper group cut significantly wider than the motor rotary ProTaper group in the outer wall, except for the apical 0 mm point. The total canal width was cut significantly larger in the hand group than in the motor group. There was no significant difference between the two groups in centering canal shape, except at the 3 mm level. These findings show that the novice students prepared the simulated curved canal that deviated more outwardly from apical 1 mm to 4 mm using the hand ProTaper. The ability to maintain the original curvature was better in the motor rotary ProTaper group than in the hand ProTaper group. Undergraduate students, if following the preparation sequence carefully, could successfully perform canal shaping by motor ProTaper files and achieve better root canal geometry than by using hand ProTaper files within the same teaching and practicing sessions.

  4. Vertical Root Fracture initiation in curved roots after root canal preparation: A dentinal micro-crack analysis with LED transillumination

    PubMed Central

    Martín-Biedma, Benjamín; Varela-Patiño, Purificación; Ruíz-Piñón, Manuel; Castelo-Baz, Pablo

    2017-01-01

    Background One of the causative factors of root defects is the increased friction produced by rotary instrumentation. A high canal curvature may increase stress, making the tooth more susceptible to dentinal cracks. The purpose of this study was to evaluate dentinal micro-crack formation with the ProTaper NEXT and ProTaper Universal systems using LED transillumination, and to analyze the micro-crack generated at the point of maximum canal curvature. Material and Methods 60 human mandibular premolars with curvatures between 30–49° and radii between 2–4 mm were used. The root canals were instrumented using the Protaper Universal® and Protaper NEXT® systems, with the aid of the Proglider® system. The obtained samples were sectioned transversely before subsequent analysis with LED transillumination at 2 mm and 8 mm from the apex and at the point of maximum canal curvature. Defects were scored: 0 for no defects; and 1 for micro-cracks. Results Root defects were not observed in the control group. The ProTaper NEXT system caused fewer defects (16.7%) than the ProTaper Universal system (40%) (P<0.05). The ProTaper Universal system caused significantly more micro-cracks at the point of maximum canal curvature than the ProTaper NEXT system (P<0.05). Conclusions Rotary instrumentation systems often generate root defects, but the ProTaper NEXT system generated fewer dentinal defects than the ProTaper Universal system. A higher prevalence of defects was found at the point of maximum curvature in the ProTaper Universal group. Key words:Curved root, Micro-crack, point of maximum canal curvature, ProTaper NEXT, ProTaper Universal, Vertical root fracture. PMID:29167712

  5. Individual and Institutional Factors of Applied STEM Coursetaking in High School

    ERIC Educational Resources Information Center

    Sublett, Cameron; Gottfried, Michael A.

    2017-01-01

    Background/Context: One approach to address the shortage of STEM-proficient high school graduates has been the development of applied STEM coursework, which seeks to increase STEM interest and retention by illustrating the interconnectedness and accessibility of STEM concepts. Importantly, however, no research has yet examined which student and…

  6. Evaluation of the Orogenic Belt Hypothesis for the Formation of Thaumasia, Mars

    NASA Astrophysics Data System (ADS)

    Nahm, A. L.; Schultz, R. A.

    2008-12-01

    The Thaumasia Highlands (TH) and Solis Planum are two of the best-known examples of compressional tectonics on Mars. The TH is a region of high topography located in the southern portion of the Tharsis Province, Mars. Solis Planum is located in eastern Thaumasia. Two hypotheses for the formation of this region have been suggested: sliding on a weak horizon or thrusting analogous to orogenic wedges on Earth. Both hypotheses require a shallowly dipping to sub-horizontal weak horizon below Thaumasia. Wrinkle ridges in Solis Planum are also inferred to sole into a décollement. If Thaumasia formed by thrusting related to sliding on a décollement, then certain conditions must be met as in critical taper wedge mechanics (CTWM) theory. If the angle between the surface slope and the basal décollement is less than predicted by the critical taper equation, the 'subcritical' wedge will deform internally until critical taper is achieved. Once the critical taper has been achieved, internal deformation ceases and the wedge will slide along its base. Formation of orogenic belts on Earth (such as the Central Mountains in Taiwan) can be described using CTWM. This method is applied here to the Thaumasia region on Mars. The surface slope (alpha) was measured in three locations: Syria Planum-Thaumasia margin, Solis Planum, and the TH. Topographic slopes were compared to the results from the critical taper equation. Because the dip of the basal décollement (beta) cannot be measured directly as on Earth, the dip angle was varied at 0 - 10 degrees; these values span the range of likely values based on terrestrial wedges. Pore fluid pressure (lambda) was varied between 0 (dry) and 0.9 (overpressured); these values span the full range of this important unknown parameter. Material properties, such as the coefficients of internal friction and of the basal décollement, were varied using reasonable values. Preliminary results show that for both reasonable (such as lambda = 0, mu b = 0.85, beta = 0 deg) and extreme (such as lambda = 0.9, mu b = 0.1, beta greater than 0 deg) values of the parameters for Mars, the predicted critical taper angle was typically lower than the measured slope, rendering the orogenic belt hypothesis for the formation of the TH invalid. Comparable analysis of Solis Planum shows it also lacks a décollement.

  7. Autonomous Cryogenic Leak Detector for Improving Launch Site Operations

    NASA Technical Reports Server (NTRS)

    Goswami, Kisholoy

    2013-01-01

    NASA, military, and commercial satellite users need launch services that are highly reliable, less complex, easier to test, and cost effective. This project has developed a tapered optical fiber sensor for detecting hydrogen. The invention involves incorporating chemical indicators on the tapered end of an optical fiber using organically modified silicate nanomaterials. The Hazardous Gas Detection Lab (HGDL) at Kennedy Space Center is involved in the design and development of instrumentation that can detect and qualify various mission-critical chemicals. Historically, hydrogen, helium, nitrogen, oxygen, and argon are the first five gases of HGDL focus. The use of these cryogenic fluids in the area of propulsion offers challenges. Due to their extreme low temperatures, these fluids induce contraction of the materials they contact, a potential cause of leakage. Among them, hydrogen is of particular concern. Small sensors are needed in multiple locations without adding to the structural weight. The most vulnerable parts of the engine are the connection flanges on the transfer lines, which have to support cycles of large thermal amplitude. The thermal protection of the engine provides a closed area, increasing the likelihood of an explosive atmosphere. Thus, even a small leak represents an unacceptable hazardous condition during loading operations, in flight, or after an aborted launch. Tapered fibers were first fabricated from 1/1.3-mm core/cladding (silica/ plastic) optical fibers. Typically a 1-ft (approx. 30- cm) section of the 1-mm fiber is cut from the bundle and marked with a pen into five 2-.-in. (.5.7-cm) sections. A propane torch is applied at every alternate mark to burn the jacket and soften the glass core. While the core is softening, the two ends of the fiber are pulled apart slowly to create fine tapers of .- to .-in. (.6- to 12-mm) long on the 1-mm optical fiber. Following this, the non-tapered ends of the fibers are polished to a 0.3-micron finish. Then these fibers were coated with indicators sensitive to hydrogen. The tapered hydrogen detection system with its unique flexibility is the only system that can be placed in many locations inside the vehicles and detect the exact location of leaks, saving millions of dollars for launch vehicle industries.

  8. Soliton propagation in tapered silicon core fibers.

    PubMed

    Peacock, Anna C

    2010-11-01

    Numerical simulations are used to investigate soliton-like propagation in tapered silicon core optical fibers. The simulations are based on a realistic tapered structure with nanoscale core dimensions and a decreasing anomalous dispersion profile to compensate for the effects of linear and nonlinear loss. An intensity misfit parameter is used to establish the optimum taper dimensions that preserve the pulse shape while reducing temporal broadening. Soliton formation from Gaussian input pulses is also observed--further evidence of the potential for tapered silicon fibers to find use in a range of signal processing applications.

  9. Monitoring techniques for the manufacture of tapered optical fibers.

    PubMed

    Mullaney, Kevin; Correia, Ricardo; Staines, Stephen E; James, Stephen W; Tatam, Ralph P

    2015-10-01

    The use of a range of optical techniques to monitor the process of fabricating optical fiber tapers is investigated. Thermal imaging was used to optimize the alignment of the optical system; the transmission spectrum of the fiber was monitored to confirm that the tapers had the required optical properties and the strain induced in the fiber during tapering was monitored using in-line optical fiber Bragg gratings. Tapers were fabricated with diameters down to 5 μm and with waist lengths of 20 mm using single-mode SMF-28 fiber.

  10. Mode conversion in a tapered fiber via a whispering gallery mode resonator and its application as add/drop filter.

    PubMed

    Huang, Ligang; Wang, Jie; Peng, Weihua; Zhang, Wending; Bo, Fang; Yu, Xuanyi; Gao, Feng; Chang, Pengfa; Song, Xiaobo; Zhang, Guoquan; Xu, Jingjun

    2016-02-01

    Based on the conversion between the fundamental mode (LP01) and the higher-order mode (LP11) in a tapered fiber via a whispering gallery mode resonator, an add/drop filter was proposed and demonstrated experimentally, in which the resonator only interacted with one tapered fiber, rather than two tapered fibers as in conventional configurations. The filter gains advantages of easy alignment and low scattering loss over the other filters based on tapered fiber and resonator, and will be useful in application.

  11. The fabrication of a tapered fiber connector and its coupling efficiency

    NASA Astrophysics Data System (ADS)

    Qinggui, Hu; Chengzhong, Li

    2017-11-01

    In order to reduce the adverse influence of transversal displacement of the optical fiber connector, we propose the directional tapered communication fiber connector, in which the fiber head is tapered according to the signal transmission direction to improve efficiency. We used a flame-brush technique to produce the tapered fiber successfully. In the next step, two experiments in different environments were performed; one in a static environment and the other in a vibration environment. The first experiment shows that the efficiency of the tapered connector is higher than that of the common connector in the same transversal displacement. The second experiment shows that the efficiency of the tapered connector is higher than that of the common connector in the same frequency and amplitude.

  12. Multiple-taper spectral analysis: A stand-alone C-subroutine

    NASA Astrophysics Data System (ADS)

    Lees, Jonathan M.; Park, Jeffrey

    1995-03-01

    A simple set of subroutines in ANSI-C are presented for multiple taper spectrum estimation. The multitaper approach provides an optimal spectrum estimate by minimizing spectral leakage while reducing the variance of the estimate by averaging orthogonal eigenspectrum estimates. The orthogonal tapers are Slepian nπ prolate functions used as tapers on the windowed time series. Because the taper functions are orthogonal, combining them to achieve an average spectrum does not introduce spurious correlations as standard smoothed single-taper estimates do. Furthermore, estimates of the degrees of freedom and F-test values at each frequency provide diagnostics for determining levels of confidence in narrow band (single frequency) periodicities. The program provided is portable and has been tested on both Unix and Macintosh systems.

  13. Supporting the STEM Pipeline: Linking Applied STEM Course-Taking in High School to Declaring a STEM Major in College

    ERIC Educational Resources Information Center

    Gottfried, Michael A.; Bozick, Robert

    2016-01-01

    Recently, through the support from the Obama administration, the traditional STEM curricula (science, technology, engineering, and mathematics) in high schools are being updated with integrated, applied STEM courses (e.g., technology and engineering) in order to enhance the "real world" applicability of scientific fields and ultimately…

  14. Nonadiabatic tapered optical fiber sensor for measuring interaction nicotine with DNA

    NASA Astrophysics Data System (ADS)

    Zibaii, M. I.; Latifi, H.; Pourbeyram, H.; Gholami, M.; Taghipour, Z.; Saeedian, Z.; Hosseini, S. M.

    2011-05-01

    A nonadiabatic tapered optical fiber sensor was utilized for studying of bimolecular interactions including DNA-DNA and DNA-Drug interaction. This work presents a simple evanescent wave sensing system based on an interferometric approach, suitable to meet the requirements of lable-free sensor systems for detecting biomolecular interactions. We have demonstrated the measuring refractive index and the real time detection of interactions between biomolecules. Furthermore basic experiments were carried out, for detecting the hybridization of 25-mer DNA with an immobilized counterpart on the surface. The overall shift after the successful DNA hybridization was 9.5 nm. In this work, a new approach for studying DNA-drug interactions was successfully tested. Nicotine as a carcinogenic compound in cigarette smoke plays an important role in interaction with DNA. Different concentrations of nicotine were applied to observe the Longmuir interaction with DNA.

  15. Comparative evaluation of rotary ProTaper, Profile, and conventional stepback technique on reduction in Enterococcus faecalis colony-forming units and vertical root fracture resistance of root canals.

    PubMed

    Singla, Mamta; Aggarwal, Vivek; Logani, Ajay; Shah, Naseem

    2010-03-01

    The purpose of this in vitro study was to evaluate the effect of various root canal instrumentation techniques with different instrument tapers on cleaning efficacy and resultant vertical root fracture (VRF) strength of the roots. Fifty human mandibular first premolar roots were enlarged to ISO size 20, inoculated with Enterococcus faecalis [ATCC2912] for 72 hours and divided into 5 groups: group I: prepared with .02 taper hand instruments ISO size 40; group II: Profile .04 taper size 40; group III: Profile .06 taper size 40; group IV: ProTaper size F4; and group V (control group) further divided into: Va: with bacterial inoculation and no mechanical instrumentation; and Group Vb: neither bacterial inoculation nor mechanical instrumentation. Cleaning efficacy was evaluated in terms of reduction of colony forming units (CFUs). The VRF strength was evaluated using D11 spreader as wedge in an Instron testing machine. Root canals instrumented with ProTaper and 6% Profile instruments showed maximum reduction in CFUs, with statistically insignificant difference between them. The VRF resistance decreased in all instrumented groups. The difference of VRF between 2% and 4% taper Profile groups was statistically insignificant (P = .195). One-way analysis of variance showed that canals instrumented with ProTaper F4 showed maximum reduction in VRF resistance compared with control uninstrumented group. Profile 6% taper instruments offer the advantage of maximum debridement without significant reduction in root fracture resistance. Copyright 2010 Mosby, Inc. All rights reserved.

  16. The effect of screw taper on interference fit during load to failure at the soft tissue/bone interface.

    PubMed

    Mann, Charles J; Costi, John J; Stanley, Richard M; Dobson, Peter J

    2005-10-01

    The effect of screw geometry on the pullout strength of an anterior cruciate ligament reconstruction is well documented. The effect of a truly tapered screw has not been previously investigated. Thirty bovine knees in right and left knee pairs were collected. Superficial digital flexors from the hind legs of sheep were harvested to form a quadruple tendon graft. For each knee pair, one tendon graft was fixed using a tapered screw (n=15) and the other with a non-tapered screw (n=15). Interference screws were manufactured from stainless steel, and apart from the tapered or non-tapered profile were identical. The screws were inserted into a tibial tunnel already containing the tendon graft. The interference fit was tested by extensile load to failure tests. The insertion torque of the screws and first sign of load to failure (by pullout) of the interference fit were recorded. Results were analysed using paired t-tests. The results indicated that tapered screws have significantly higher resistance to interference failure (p=0.007) and insertion torque (p<0.001) than non-tapered screws. The improved biomechanical performance of tapered screws demonstrated in this study may translate into superior clinical results, particularly at the tibial attachment of hamstring anterior cruciate ligament reconstruction, and also of hamstring fixation to the medial femoral condyle for patella instability.

  17. Investigations of the fabrication and the surface-enhanced Raman scattering detection applications for tapered fiber probes prepared with the laser-induced chemical deposition method.

    PubMed

    Fan, Qunfang; Cao, Jie; Liu, Ye; Yao, Bo; Mao, Qinghe

    2013-09-01

    The process of depositing nanoparticles onto tapered fiber probes with the laser-induced chemical deposition method (LICDM) and the surface-enhanced Raman scattering (SERS) detection performance of the prepared probes are experimentally investigated in this paper. Our results show that the nanoparticle-deposited tapered fiber probes prepared with the LICDM method depend strongly on the value of the cone angle. For small-angle tapered probes the nanoparticle-deposited areas are only focused at the taper tips, because the taper surfaces are mainly covered by a relatively low-intensity evanescent field. By lengthening the reaction time or increasing the induced power or solution concentration, it is still possible to deposit nanoparticles on small-angle tapers with the light-scattering effect. With 4-aminothiophenol as the testing molecule, it was found that for given preparation conditions, the cone angles for the tapered probes with the highest SERS spectral intensities for different excitation laser powers are almost the same. However, such an optimal cone angle is determined by the combined effects of both the localized surface plasmon resonance strength and the transmission loss generated by the nanoparticles deposited.

  18. 29 CFR 1926.251 - Rigging equipment for material handling.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... splices, the U-bolt shall be applied so that the “U” section is in contact with the dead end of the rope... laid grommets and endless slings shall have a minimum circumferential length of 96 times their body... be tapered and spliced into the body of the rope using at least two additional tucks (which will...

  19. 29 CFR 1926.251 - Rigging equipment for material handling.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... splices, the U-bolt shall be applied so that the “U” section is in contact with the dead end of the rope... laid grommets and endless slings shall have a minimum circumferential length of 96 times their body... be tapered and spliced into the body of the rope using at least two additional tucks (which will...

  20. Hand-operated and rotary ProTaper instruments: a comparison of working time and number of rotations in simulated root canals.

    PubMed

    Pasqualini, Damiano; Scotti, Nicola; Tamagnone, Lorenzo; Ellena, Federica; Berutti, Elio

    2008-03-01

    The aim of this study was to compare the effective shaping time and number of rotations required by an endodontist working with hand and rotary ProTaper instruments to completely shape simulated root canals. Eighty Endo Training Blocks (curved canal shape) were used. Manual preflaring was performed with K-Flexofiles #08-10-12-15-17 and #20 Nitiflex at a working length of 18 mm. Specimens were then randomly assigned to 2 different groups (n = 40); group 1 was shaped by using hand ProTaper and group 2 with ProTaper rotary. The number of rotations made in the canal and the effective time required to achieve complete canal shaping were recorded for each instrument. Differences between groups were analyzed with the nonparametric Mann-Whitney U test (P < .05). Hand ProTaper required significantly fewer rotations (P < .001) than rotary ProTaper, whereas the effective working time to fully shape the simulated canal was significantly higher (P < .001) with hand ProTaper.

  1. 1.4-7.2  μm broadband supercontinuum generation in an As-S chalcogenide tapered fiber pumped in the normal dispersion regime.

    PubMed

    Wang, Yingying; Dai, Shixun; Li, Guangtao; Xu, Dong; You, Chenyang; Han, Xin; Zhang, Peiqing; Wang, Xunsi; Xu, Peipeng

    2017-09-01

    We report a broadband supercontinuum (SC) generation in chalcogenide (ChG) step-index tapered fibers pumped in the normal dispersion regime. The fibers consisting of As 2 S 3 core and As 38 S 62 cladding glasses were fabricated using the isolated stacked extrusion method. A homemade tapering platform allows us to accurately control the core diameters and transition region lengths of the tapered fibers. An SC generation spanning from 1.4 to 7.2 μm was achieved by pumping a 12-cm-long tapered fiber with femtosecond laser pulses at 3.25 μm. To the best of our knowledge, this is the broadest SC generation obtained experimentally in tapered fibers when pumped in the normal dispersion regime so far. The effects of waist diameter and transition region length of the tapered fiber on the SC spectral behavior were also investigated.

  2. Supercontinuum generation from 437 to 2850 nm in a tapered fluorotellurite microstructured fiber

    NASA Astrophysics Data System (ADS)

    Wang, F.; Jia, Z. X.; Yao, C. F.; Wang, S. B.; Hu, M. L.; Wu, C. F.; Ohishi, Y.; Qin, W. P.; Qin, G. S.

    2016-12-01

    We demonstrated supercontinuum (SC) generation in a tapered fluorotellurite microstructured fiber (MF) with a sub-micrometer core diameter. Fluorotellurite MFs based on TeO2-BaF2-Y2O3 glasses were fabricated by using a rod-in-tube method and a tapered fluorotellurite MF with a minimum core diameter of ~0.65 µm was prepared by employing a tapering system. A 1560 nm femtosecond fiber laser was used as the pumping source. With increasing the peak power of the launched pump laser to ~11 kW, SC light expanding from 437 to 2850 nm was generated in the tapered fluorotellurite MF. In addition, relatively strong blue-shifted dispersive wave at ~489 nm was also observed from the tapered fluorotellurite MF.

  3. Ultra-low-loss optical fiber nanotapers.

    PubMed

    Brambilla, Gilberto; Finazzi, Vittoria; Richardson, David

    2004-05-17

    Optical fiber tapers with a waist size larger than 1microm are commonplace in telecommunications and sensor applications. However the fabrication of low-loss optical fiber tapers with subwavelength diameters was previously thought to be impractical due to difficulties associated with control of the surface roughness and diameter uniformity. In this paper we show that very-long ultra-low-loss tapers can in fact be produced using a conventional fiber taper rig incorporating a simple burner configuration. For single-mode operation, the optical losses we achieve at 1.55microm are one order of magnitude lower than losses previously reported in the literature for tapers of a similar size. SEM images confirm excellent taper uniformity. We believe that these low-loss structures should pave the way to a whole range of fiber nanodevices.

  4. Application of stem cells in targeted therapy of breast cancer: a systematic review.

    PubMed

    Madjd, Zahra; Gheytanchi, Elmira; Erfani, Elham; Asadi-Lari, Mohsen

    2013-01-01

    The aim of this systematic review was to investigate whether stem cells could be effectively applied in targeted therapy of breast cancer. A systematic literature search was performed for original articles published from January 2007 until May 2012. Nine studies met the inclusion criteria for phase I or II clinical trials, of which three used stem cells as vehicles, two trials used autologous hematopoetic stem cells and in four trials cancer stem cells were targeted. Mesenchymal stem cells (MSCs) were applied as cellular vehicles to transfer therapeutic agents. Cell therapy with MSC can successfully target resistant cancers. Cancer stem cells were selectively targeted via a proteasome-dependent suicide gene leading to tumor regression. Wnt/β-catenin signaling pathway has been also evidenced to be an attractive CSC-target. This systematic review focused on two different concepts of stem cells and breast cancer marking a turning point in the trials that applied stem cells as cellular vehicles for targeted delivery therapy as well as CSC-targeted therapies. Applying stem cells as targeted therapy could be an effective therapeutic approach for treatment of breast cancer in the clinic and in therapeutic marketing; however this needs to be confirmed with further clinical investigations.

  5. The use of reinforced composite resin cement as compensation for reduced post length.

    PubMed

    Nissan, J; Dmitry, Y; Assif, D

    2001-09-01

    Cements that yield high retentive values are believed to allow use of shorter posts. This study investigated the use of reinforced composite resin cement as compensation for reduced dowel length. The retention values of stainless steel posts (parallel-sided ParaPost and tapered Dentatus in 5-, 8-, and 10-mm lengths) luted with Flexi-Flow titanium-reinforced composite resin and zinc phosphate cements were evaluated. Single-rooted extracted human teeth with crowns (n = 120), removed at the cementoenamel junction, were randomly divided into 4 groups of 30 samples each. Different post lengths were luted with either Flexi-Flow or zinc phosphate. Each sample was placed into a specialized jig and on a tensile testing machine with a crosshead speed of 2 mm/min, applied until failure. The effect of different posts and cements on the force required to dislodge the dowels was evaluated with multiple analyses of variance (ANOVA). One-way ANOVA with Scheffé contrast was applied to determine the effect of different post lengths on the retentive failure of posts luted with the 2 agents. Flexi-Flow reinforced composite resin cement significantly increased retention of ParaPost and Dentatus dowels (P<.001) compared with zinc phosphate. One-way ANOVA revealed no statistically significant difference (P>.05) between mean retention of both dowels luted with Flexi-Flow for all posts length used (5 mm = 8 mm = 10 mm). Mean retention values of the groups luted with zinc phosphate showed a statistically significant difference (P<.001) for the different post lengths (10 > 8 > 5 mm). Parallel-sided ParaPost dowels demonstrated a higher mean retention than tapered Dentatus dowels (P<.001). In this study, Flexi-Flow reinforced composite resin cement compensated for the reduced length of shorter parallel-sided ParaPost and tapered Dentatus dowels.

  6. Dwarf mistletoe does not increase trunk taper in released red firs in California

    Treesearch

    Robert F. Scharpf

    1977-01-01

    Dwarf mistletoe had no noticeable effect on trunk taper of young, dominant and codominant red firs 4 to 22 inches (10.2 to 55.9 cm) d.b.h. Also, taper was not influenced by live crown ratio of infected and uninfected trees. Trees less than 7 inches d.b.h. had significantly more taper than larger trees, irrespective of dwarf mistletoe.

  7. Comparison of the fracture resistance of dental implants with different abutment taper angles.

    PubMed

    Wang, Kun; Geng, Jianping; Jones, David; Xu, Wei

    2016-06-01

    To investigate the effects of abutment taper angles on the fracture strength of dental implants with TIS (taper integrated screwed-in) connection. Thirty prototype cylindrical titanium alloy 5.0mm-diameter dental implants with different TIS-connection designs were divided into six groups and tested for their fracture strength, using a universal testing machine. These groups consisted of combinations of 3.5 and 4.0 mm abutment diameter, each with taper angles of 6°, 8° or 10°. 3-Dimensional finite element analysis (FEA) was also used to analyze stress states at implant-abutment connection areas. In general, the mechanical tests found an increasing trend of implant fracture forces as the taper angle enlarged. When the abutment diameter was 3.5 mm, the mean fracture forces for 8° and 10° taper groups were 1638.9 N ± 20.3 and 1577.1 N ± 103.2, respectively, both larger than that for the 6° taper group of 1475.0 N ± 24.4, with the largest increasing rate of 11.1%. Furthermore, the difference between 8° and 6° taper groups was significant, based on Tamhane's multiple comparison test (P<0.05). In 4.0 mm-diameter abutment groups, as the taper angle was enlarged from 6° to 8° and 10°, the mean fracture value was increased from 1066.7 N ± 56.1 to 1241.4 N ± 6.4 and 1419.3 N ± 20.0, with the largest increasing rate of 33.1%, and the differences among the three groups were significant (P<0.05). The FEA results showed that stress values varied in implants with different abutment taper angles and supported the findings of the static tests. In conclusion, increases of the abutment taper angle could significantly increase implant fracture resistance in most cases established in the study, which is due to the increased implant wall thickness in the connection part resulting from the taper angle enlargement. The increasing effects were notable when a thin implant wall was present to accommodate wide abutments. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Multiplex and simultaneous measurement of displacement and temperature using tapered fiber and fiber Bragg grating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ji Chongke; Zhao Chunliu; Kang Juan

    2012-05-15

    A simple method to work out the multiplexing of tapered fiber based sensors is proposed and demonstrated. By cascading a tapered fiber with a fiber Bragg grating (FBG), the sensor head is provided with a wavelength identification, different FBGs provide the sensor heads with different reflective peaks and they can be distinguished in optical spectrum. By compositing several such sensor heads with a multi-channel beam splitter, a star-style topological structure sensor for multipoint sensing is achieved. At the same time, the output intensity at the peak wavelength is sensitive to one external physical parameter applied on the related FBG-cascaded taperedmore » fiber and the central wavelength of the peak is only sensitive to temperature, so that that parameter and temperature can be measured simultaneously. A sensor for dual-point measurement of the displacement and temperature simultaneously is experimentally demonstrated by using a 2 x 2 coupler in this paper. Experiment results show that the sensor works well and the largest sensitivities reach to 0.11 dB/{mu}m for displacement in the range of 0-400 {mu}m, and {approx}0.0097 nm/ deg. C for temperature between 20 deg. C and 70 deg. C.« less

  9. In Vitro Microbiological Analysis of Bacterial Seal in Hybrid Zirconia Abutment Tapered Connection.

    PubMed

    Harlos, Maurício Marcelo; Bezerra da Silva, Thiago; Peruzzo, Daiane C; Napimoga, Marcelo H; Joly, Julio Cesar; Martinez, Elizabeth F

    2017-04-01

    The aim of this study was to evaluate the bacterial seal at the implant-hybrid zirconia abutment interface and Morse taper-type connections through in vitro microbiological analysis. Sixteen implants and their respective abutments were divided into 3 groups: test (10 sets), positive control (3 sets), and negative control (3 sets). In the test group, 10 implants were contaminated with Escherichia coli using a sterile inoculating loop to the inner portion of the implants, followed by torque application to the abutment (30 N·cm). The positive controls were also contaminated, but no torque was applied to the abutment screw. The negative control consisted of uncontaminated sets. All specimens were immersed in test tubes containing 5 mL brain heart infusion (BHI) broth, maintained in a microbiological incubator for 14 days at 37°C under aerobic conditions, and monitored every 24 hours for evidence of bacterial growth. During the 14 days of incubation, no significant increase in the number of cloudy culture media was observed in the test group (P = 0.448). No significant difference in broth turbidity ratio was observed (P > 0.05). Hybrid zirconia abutments can create an effective seal at the tapered abutment-implant interface with a 30-N·cm installation torque.

  10. Improved oil-off survivability of tapered roller bearings

    NASA Technical Reports Server (NTRS)

    Kreider, Gary E.; Lee, Peter W.

    1987-01-01

    The aim of this program is to improve the oil-off survivability of a tapered roller bearing when applied to a helicopter transmission, since the tapered bearing has shown a performance advantage in this application. However, the critical roller end-rib conjunction is vulnerable to damage in an oil-off condition. Three powdered metal materials were selected to use as the rib material for oil-off evaluation. These were: M2 steel to a 65% density, CBS 1000M 65% density, and CBS 1000M 75% density. The bearing styles tested were ribbed cone (inner race) and ribbed cup (outer race). Carburized solid CBS 600 was also used as a ribbed material for comparison of oil-off results. The tests were conducted at six speeds from 4000 rpm (0.26 million DN) through 37000 rpm (2.4 million DN).The ribbed cup style bearing achieved longer lives than the ribbed cone style. A standard bearing lasted only 10 minutes at 4000 rpm; however, the 30-min oil-off goal was achieved through 11000 rpm using the survivable ribbed cup bearing. The oil-off lives at 37000 rpm were less than 10 seconds. The grinding of the powder metal materials and surface preparation to achieve an open porosity is extremely critical to the oil-off performance of the powder metal component.

  11. Functional significance of the taper of vertebrate cone photoreceptors

    PubMed Central

    Hárosi, Ferenc I.

    2012-01-01

    Vertebrate photoreceptors are commonly distinguished based on the shape of their outer segments: those of cones taper, whereas the ones from rods do not. The functional advantages of cone taper, a common occurrence in vertebrate retinas, remain elusive. In this study, we investigate this topic using theoretical analyses aimed at revealing structure–function relationships in photoreceptors. Geometrical optics combined with spectrophotometric and morphological data are used to support the analyses and to test predictions. Three functions are considered for correlations between taper and functionality. The first function proposes that outer segment taper serves to compensate for self-screening of the visual pigment contained within. The second function links outer segment taper to compensation for a signal-to-noise ratio decline along the longitudinal dimension. Both functions are supported by the data: real cones taper more than required for these compensatory roles. The third function relates outer segment taper to the optical properties of the inner compartment whereby the primary determinant is the inner segment’s ability to concentrate light via its ellipsoid. In support of this idea, the rod/cone ratios of primarily diurnal animals are predicted based on a principle of equal light flux gathering between photoreceptors. In addition, ellipsoid concentration factor, a measure of ellipsoid ability to concentrate light onto the outer segment, correlates positively with outer segment taper expressed as a ratio of characteristic lengths, where critical taper is the yardstick. Depending on a light-funneling property and the presence of focusing organelles such as oil droplets, cone outer segments can be reduced in size to various degrees. We conclude that outer segment taper is but one component of a miniaturization process that reduces metabolic costs while improving signal detection. Compromise solutions in the various retinas and retinal regions occur between ellipsoid size and acuity, on the one hand, and faster response time and reduced light sensitivity, on the other. PMID:22250013

  12. Successful treatment of dry eye in two patients with chronic graft-versus-host disease with systemic administration of FK506 and corticosteroids.

    PubMed

    Ogawa, Y; Okamoto, S; Kuwana, M; Mori, T; Watanabe, R; Nakajima, T; Yamada, M; Mashima, Y; Tsubota, K; Oguchi, Y

    2001-05-01

    We present two cases of severe dry eye in patients with chronic graft-versus-host disease (CGVHD) after hematopoietic stem cell transplantation (SCT) who were successfully treated by the systemic administration of FK506 and corticosteroids. A 29-year-old man with chronic myelogenous leukemia underwent SCT. Oral and lung CGVHD developed on approximately day 130, and dry eye associated with CGVHD was diagnosed on day 168. The patient began receiving cyclosporin A (150 mg/d) for the treatment of oral and lung CGVHD. Treatment with prednisolone (1 mg/kg/d) began on approximately day 300. Oral and lung GVHD improved slightly, but worsened again although systemic administration of cyclosporin A and prednisolone were continued. Cyclosporin A was discontinued, and systemic administration of FK506 was started on day 376. Forty-four days later, marked improvement in the ocular surface and other organs was observed. However, the dry eye worsened while tapering FK506, with no flare of other affected organs. A 43-year-old woman with myelodysplastic syndrome underwent SCT. She received FK506 for prophylaxis of CGVHD. She had mild dry eye before SCT. Oral and intestinal CGVHD developed, and the dry eye worsened significantly on approximately day 150 while tapering FK506. Treatment with prednisolone (1 mg/kg/d) began, and the dose of FK506 was increased. By day 240, the symptoms of dry eye and the findings of the ocular surface markedly improved, and CGVHD in other organs was completely resolved. However, the improvement in the dry eye was lost when FK506 was tapered for the second time. Systemic administration of FK506 with corticosteroids is an effective treatment of severe dry eye in patients with CGVHD, but long-term administration may be required to achieve a lasting response. These cases also suggest that further investigation into the use of topical FK506 and prednisolone as a maintenance therapy should be pursued.

  13. Cyclic fatigue resistance of two nickel-titanium rotary instruments in interrupted rotation.

    PubMed

    Pedullà, E; Lizio, A; Scibilia, M; Grande, N M; Plotino, G; Boninelli, S; Rapisarda, E; Lo Giudice, G

    2017-02-01

    To investigate the influence of interrupted rotation on cyclic fatigue of two nickel-titanium rotary instruments. Cyclic fatigue of 300 new ProTaper Next size X1; X2 and Mtwo size 10, .04 taper; size 15, .05 taper; size 20, .06 taper and size 25, .06 taper instruments was tested in continuous or interrupted rotation. Fifty files of the same brand and size were randomly assigned to five groups (n = 10). Group 1 instruments were tested in continuous rotation; groups 2 and 3 in paused rotation for 1 s every 10 or 20 s, respectively; groups 4 and 5 in interrupted rotation for 5 s every 10 or 20 s, respectively. Cyclic fatigue was expressed in time to fracture (TtF) in an artificial canal with 60° angle and 5 mm radius of curvature. The fracture surface was examined with a scanning electron microscope (SEM). Data were evaluated by two-way analysis of variance. Cyclic fatigue of groups 2 and 4 of ProTaper Next X2 and Mtwo size 25, .06 taper was significantly lower than that of group 1 of the same instruments (P < 0.01). ProTaper Next X2 had significantly reduced cyclic fatigue in groups 3 and 5 (P < 0.05). No differences were found by interrupting the rotation for 1 or 5 s in all instruments (P > 0.05). Fatigue of other instruments was not affected by interrupted rotation (P > 0.05). Interrupted rotation reduced cyclic fatigue resistance of ProTaper Next X2 and Mtwo size 25, .06 taper, especially when a higher number of interruptions was performed. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  14. Three-dimensional patterning in polymer optical waveguides using focused ion beam milling

    NASA Astrophysics Data System (ADS)

    Kruse, Kevin; Burrell, Derek; Middlebrook, Christopher

    2016-07-01

    Waveguide (WG) photonic-bridge taper modules are designed for symmetric planar coupling between silicon WGs and single-mode fibers (SMFs) to minimize photonic chip and packaging footprint requirements with improving broadband functionality. Micromachined fabrication and evaluation of polymer WG tapers utilizing high-resolution focused ion beam (FIB) milling is performed and presented. Polymer etch rates utilizing the FIB and optimal methods for milling polymer tapers are identified for three-dimensional patterning. Polymer WG tapers with low sidewall roughness are manufactured utilizing FIB milling and optically tested for fabrication loss. FIB platforms utilize a focused beam of ions (Ga+) to etch submicron patterns into substrates. Fabricating low-loss polymer WG taper prototypes with the FIB before moving on to mass-production techniques provides theoretical understanding of the polymer taper and its feasibility for connectorization devices between silicon WGs and SMFs.

  15. Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model.

    PubMed

    Yao, James H; Schwartz, Scott A; Beeson, Thomas J

    2006-01-01

    The cyclic fatigue resistance of three types of nickel-titanium rotary files was compared in a model using reciprocating axial movement. The influence of file size and taper was also investigated and fracture patterns were examined under SEM. The 10 experimental groups consisted of ProFiles, K3s, and RaCe files, size 25 in .04 and .06 tapers, as well as ProFiles and K3s, size 40 in .04 and .06 tapers. Each file was rotated freely at 300 rpm inside a stainless steel tube with a 60 degree and 5 mm radius of curvature. A continuous 3 mm oscillating axial motion was applied at 1 cycle per second by attaching an electric dental handpiece to the most inferior load cell of an Instron machine using a custom-made jig. The number of rotations to failure was determined and analyzed using analysis of variance and Tukey's post hoc tests. Overall, K3 25/.04 files were significantly more resistant to cyclic fatigue compared to any other group in this study. In the 25/.04 category, K3s were significantly more resistant to failure than ProFiles and RaCe files. Also in the same category, ProFiles significantly outlasted RaCe files. In the 25/.06 group, K3s and ProFiles were significantly more resistant to failure than RaCe files, but K3s were not significantly different than ProFiles. In the 40/.04 and 40/.06 groups, K3s were significantly more resistant to cyclic fatigue than ProFiles. SEM observations demonstrated mostly a ductile mode of fracture. The results suggest that different cross-sectional designs, diameters, and tapers all contribute to a nickel-titanium instrument's vulnerability to cyclic failure.

  16. Opioid withdrawal, craving, and use during and after outpatient buprenorphine stabilization and taper: a discrete survival and growth mixture model.

    PubMed

    Northrup, Thomas F; Stotts, Angela L; Green, Charles; Potter, Jennifer S; Marino, Elise N; Walker, Robrina; Weiss, Roger D; Trivedi, Madhukar

    2015-02-01

    Most patients relapse to opioids within one month of opioid agonist detoxification, making the antecedents and parallel processes of first use critical for investigation. Craving and withdrawal are often studied in relationship to opioid outcomes, and a novel analytic strategy applied to these two phenomena may indicate targeted intervention strategies. Specifically, this secondary data analysis of the Prescription Opioid Addiction Treatment Study used a discrete-time mixture analysis with time-to-first opioid use (survival) simultaneously predicted by craving and withdrawal growth trajectories. This analysis characterized heterogeneity among prescription opioid-dependent individuals (N=653) into latent classes (i.e., latent class analysis [LCA]) during and after buprenorphine/naloxone stabilization and taper. A 4-latent class solution was selected for overall model fit and clinical parsimony. In order of shortest to longest time-to-first use, the 4 classes were characterized as 1) high craving and withdrawal, 2) intermediate craving and withdrawal, 3) high initial craving with low craving and withdrawal trajectories and 4) a low initial craving with low craving and withdrawal trajectories. Odds ratio calculations showed statistically significant differences in time-to-first use across classes. Generally, participants with lower baseline levels and greater decreases in craving and withdrawal during stabilization combined with slower craving and withdrawal rebound during buprenorphine taper remained opioid-free longer. This exploratory work expanded on the importance of monitoring craving and withdrawal during buprenorphine induction, stabilization, and taper. Future research may allow individually tailored and timely interventions to be developed to extend time-to-first opioid use. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Influence of cyclic torsional preloading on cyclic fatigue resistance of nickel - titanium instruments.

    PubMed

    Pedullà, E; Lo Savio, F; Boninelli, S; Plotino, G; Grande, N M; Rapisarda, E; La Rosa, G

    2015-11-01

    To evaluate the effect of different torsional preloads on cyclic fatigue resistance of endodontic rotary instruments constructed from conventional nickel-titanium (NiTi), M-Wire or CM-Wire. Eighty new size 25, 0.06 taper Mtwo instruments (Sweden & Martina), size 25, 0.06 taper HyFlex CM (Coltene/Whaledent, Inc) and X2 ProTaper Next (Dentsply Maillefer) were used. The Torque and distortion angles at failure of new instruments (n = 10) were measured, and 0% (n = 10), 25%, 50% and 75% (n = 20) of the mean ultimate torsional strength as preloading condition were applied according to ISO 3630-1 for each brand. The twenty files tested for every extent of preload were subjected to 20 or 40 torsional cycles (n = 10). After torsional preloading, the number of cycles to failure was evaluated in a simulated canal with 60° angle of curvature and 5 mm of radius of curvature. Data were analysed using two-way analysis of variance. The fracture surface of each fragment was examined with a scanning electron microscope (SEM). Data were analysed by two-way analyses of variance. Preload repetitions did not influence the cyclic fatigue of the three brands; however, the 25%, 50% and 75% torsional preloading significantly reduced the fatigue resistance of all instruments tested (P < 0.01, P < 0.001 and P < 0.0001, respectively) except for the HyFlex CM preloaded with 25% of the maximum torsional strength (P > 0.05). Torsional preloads reduced the cyclic fatigue resistance of conventional and treated (M-wire and CM-wire) NiTi rotary instruments except for size 25, 0.06 taper HyFlex CM instruments with a 25% of torsional preloading. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  18. Incidence of microcracks in maxillary first premolars after instrumentation with three different mechanized file systems: a comparative ex vivo study.

    PubMed

    Kfir, A; Elkes, D; Pawar, A; Weissman, A; Tsesis, I

    2017-01-01

    The objective of this study is to determine the potential for microcracks in the radicular dentin of first maxillary premolars using three different mechanized endodontic instrumentation systems. Eighty extracted maxillary first premolars with two root canals and no externally visible microcracks were selected. Root canal instrumentation was performed with either the ProTaper file system, the WaveOne primary file, or the self-adjusting file (SAF). Teeth with intact roots served as controls. The roots were cut into segments and examined with an intensive, small-diameter light source that was applied diagonally to the entire periphery of the root slice under ×20 magnification; the presence of microcracks and fractures was recorded. Pearson's chi-square method was used for statistical analysis, and significance was set at p < 0.05. Microcracks were present in 30 and 20 % of roots treated with the ProTaper and WaveOne systems, respectively, while no microcracks were present in the roots treated with the SAF (p = 0.008 and p = 0.035, respectively). Intact teeth presented with cracks in 5 % of the roots. The intensive, small-diameter light source revealed microcracks that could not be detected when using the microscope's light alone. Within the limitations of this study, it could be concluded that mechanized root canal instrumentation with the ProTaper and WaveOne systems in maxillary first premolars causes microcracks in the radicular dentin, while the use of the SAF file causes no such microcracks. Rotary and reciprocating files with large tapers may cause microcracks in the radicular dentin of maxillary first premolars. Less aggressive methods should be considered for these teeth.

  19. Tapered fiber optical tweezers for microscopic particle trapping: fabrication and application

    NASA Astrophysics Data System (ADS)

    Liu, Zhihai; Guo, Chengkai; Yang, Jun; Yuan, Libo

    2006-12-01

    A novel single tapered fiber optical tweezers is proposed and fabricated by heating and drawing technology. The microscopic particle tapping performance of this special designed tapered fiber probe is demonstrated and investigated. The distribution of the optical field emerging from the tapered fiber tip is numerically calculated based on the beam propagation method. The trapping force FDTD analysis results, both axial and transverse, are also given.

  20. Supercontinuum generation in an imaging fiber taper

    NASA Astrophysics Data System (ADS)

    Shi, Kebin; Omenetto, Fiorenzo G.; Liu, Zhiwen

    2006-12-01

    We report on supercontinuum generation in individual fibers of a commercial Schott imaging fiber taper. Supercontinuum spectrum covering a wavelength range from about 500 nm to 1 μm was obtained. Unlike conventional approaches which use either a single micro-structured photonic crystal fiber (PCF) or an individual fiber or PCF taper, the availability of many fibers in an imaging taper can open new possibilities to independently and controllably generate supercontinuum arrays.

  1. Comparison of debris extruded apically and working time used by ProTaper Universal rotary and ProTaper retreatment system during gutta-percha removal

    PubMed Central

    UEZU, Mary Kinue Nakamune; BRITTO, Maria Leticia Borges; NABESHIMA, Cleber K.; PALLOTTA, Raul Capp

    2010-01-01

    Objective The aim of this study was to evaluate the in vitro action of ProTaper retreatment files and ProTaper Universal in the retreatment of mandibular premolars. Material and methods The amount of debris extruded apically was measured and the time to reach the working length and to complete the removal of gutta-percha was observed. Thirty teeth had their canals prepared using ProTaper Universal files and were obturated by the single cone technique. The teeth were then stored at 37ºC in a humid environment for 7 days. During the use of the rotary instruments for root canal filling removal, the apical portions of the teeth were attached to the open end of a resin tube to collect the apically extruded debris. Results ProTaper Universal files were significantly faster (p=0.0011) than the ProTaper retreatment files to perform gutta-percha removal, but no significant difference was found between the files regarding the time to reach the working length or the amount of apical extrusion. Conclusions ProTaper Universal rotary had better results for endodontic retreatment, and both techniques promote similar apical extrusion of debris. PMID:21308282

  2. Strain energy release rate analysis of delamination in a tapered laminate subjected to tension load

    NASA Technical Reports Server (NTRS)

    Salpekar, S. A.; Raju, I. S.; Obrien, T. K.

    1990-01-01

    A tapered composite laminate subjected to tension load was analyzed using the finite-element method. The glass/epoxy laminate has a (+ or - 45)sub 3 group of plies dropped in three distinct steps, each 20 ply-thicknesses apart, thus forming a taper angle of 5.71 degrees. Steep gradients of interlaminar normal and shear stress on a potential delamination interface suggest the existence of stress singularities at the points of material and geometric discontinuities created by the internal plydrops. The delamination was assumed to initiate at the thin end of the taper on a -45/+45 interface and the delamination growth was simulated in both directions, i.e., along the taper and into the thin region. The strain-energy-release rate for a delamination growing into the thin laminate consisted predominantly of mode I (opening) component. For a delamination growing along the tapered region, the strain-energy-release rate was initially all mode I, but the proportion of mode I decreased with increase in delamination size until eventually total G was all mode II. The total G for both delamination tips increased with increase in delamination size, indicating that a delamination initiating at the end of the taper will grow unstably along the taper and into the thin laminate simultaneously.

  3. Mid-infrared supercontinuum generation spanning from 1.9 to 5.7 μm in a chalcogenide fiber taper with ultra-high NA

    NASA Astrophysics Data System (ADS)

    Wang, Yingying; Dai, Shixun; Peng, Xuefeng; Zhang, Peiqing; Wang, Xunsi; You, Chenyang

    2018-01-01

    We report a broadband supercontinuum generation in a chalcogenide fiber taper with an ultra-high numerical aperture. The chalcogenide step-index fiber consisting of As2Se3 core and As2S3 cladding was fabricated by using the isolated stacked extrusion method. The fiber taper with a core diameter of 1.75 μm was prepared by employing a homemade tapering setup. By pumping the fiber taper with a femtosecond laser pulses at 3.3 μm, a broadband supercontinuum generation spanning from 1.9 to 5.7 μm was achieved.

  4. Multimode Brillouin spectrum in a long tapered birefringent photonic crystal fiber.

    PubMed

    Tchahame, Joël Cabrel; Beugnot, Jean-Charles; Kudlinski, Alexandre; Sylvestre, Thibaut

    2015-09-15

    We investigate the stimulated Brillouin scattering (SBS) in a long tapered birefringent solid-core photonic crystal fiber (PCF) and compare our results with a similar but untapered PCF. It is shown that the taper generates a broadband and multipeaked Brillouin spectrum, while significantly increasing the threshold power. Furthermore, we observe that the strong fiber birefringence gives rise to a frequency shift of the Brillouin spectrum which increases along the fiber. Numerical simulations are also presented to account for the taper effect and the birefringence. Our findings open a new means to control or inhibit the SBS by tapering photonic crystal fibers.

  5. Ultra-low-loss tapered optical fibers with minimal lengths

    NASA Astrophysics Data System (ADS)

    Nagai, Ryutaro; Aoki, Takao

    2014-11-01

    We design and fabricate ultra-low-loss tapered optical fibers (TOFs) with minimal lengths. We first optimize variations of the torch scan length using the flame-brush method for fabricating TOFs with taper angles that satisfy the adiabaticity criteria. We accordingly fabricate TOFs with optimal shapes and compare their transmission to TOFs with a constant taper angle and TOFs with an exponential shape. The highest transmission measured for TOFs with an optimal shape is in excess of 99.7 % with a total TOF length of only 23 mm, whereas TOFs with a constant taper angle of 2 mrad reach 99.6 % transmission for a 63 mm TOF length.

  6. Characterization of the fretting corrosion behavior, surface and debris from head-taper interface of two different modular hip prostheses.

    PubMed

    Dos Santos, Claudio T; Barbosa, Cassio; Monteiro, Maurício J; Abud, Ibrahim C; Caminha, Ieda M V; Roesler, Carlos R M

    2016-09-01

    Modular hip prostheses are flexible to match anatomical variations and to optimize mechanical and tribological properties of each part by using different materials. However, micromotions associated with the modular components can lead to fretting corrosion and, consequently, to release of debris which can cause adverse local tissue reactions in human body. In the present study, the surface damage and residues released during in vitro fretting corrosion tests were characterized by stereomicroscope, SEM and EDS. Two models of modular hip prosthesis were studied: Model SS/Ti Cementless whose stem was made of ASTM F136 Ti-6Al-4V alloy and whose metallic head was made of ASTM F138 austenitic stainless steel, and Model SS/SS Cemented with both components made of ASTM F138 stainless steel. The fretting corrosion tests were evaluated according to the criteria of ASTM F1875 standard. Micromotions during the test caused mechanical wear and material loss in the head-taper interface, resulting in fretting-corrosion. Model SS/SS showed higher grade of corrosion. Different morphologies of debris predominated in each model studied. Small and agglomerated particles were observed in the Model SS/Ti and irregular particles in the Model SS/SS. After 10 million cycles, the Model SS/Ti was more resistant to fretting corrosion than the Model SS/SS. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Photonic lantern with multimode fibers embedded

    NASA Astrophysics Data System (ADS)

    Yu, Hai-Jiao; Yan, Qi; Huang, Zong-Jun; Tian, He; Jiang, Yu; Liu, Yong-Jun; Zhang, Jian-Zhong; Sun, Wei-Min

    2014-08-01

    A photonic lantern is studied which is formed by seven multimode fibers inserted into a pure silica capillary tube. The core of the tapered end has a uniform refractive index because the polymer claddings are removed before the fibers are inserted. Consequently, the light distribution is also uniform. Two theories describing a slowly varying waveguide and multimode coupling are used to analyze the photonic lantern. The transmission loss decreases as the length of the tapered part increases. For a device with a taper length of 3.4 cm, the loss is about 1.06 dB on average for light propagating through the taper from an inserted fiber to the tapered end and 0.99 dB in the reverse direction. For a device with a taper length of 0.7 cm, the two loss values are 2.63 dB and 2.53 dB, respectively. The results show that it is possible to achieve a uniform light distribution with the tapered end and a low-loss transmission in the device if parameters related to the lantern are reasonably defined.

  8. A Tree Taper Model Based on Similar Triangles and Use of Crown Ratio as a Measure of Form in Taper Equations for Longleaf Pine

    Treesearch

    Dennis J. Shaw; Ralph S. Meldahl; John S. Kush; Greg L. Somers

    2003-01-01

    We used data from 322 natural longleaf pine (Pinus palustris Mill.) trees to include crown ratio as a continuous variable in taper equations. The data were divided into 10 crown-ratio classes and fitted taper equations into each class to detect trends in the coefficients. For application to longleaf pine, we replaced coefficients that exhibited a...

  9. STIR-Physics: Cold Atoms and Nanocrystals in Tapered Nanofiber and High-Q Resonator Potentials

    DTIC Science & Technology

    2016-11-02

    STIR- Physics : Cold Atoms and Nanocrystals in Tapered Nanofiber and High-Q Resonator Potentials We worked on a tapered fiber in cold atomic cloud...reviewed journals: Number of Papers published in non peer-reviewed journals: Final Report: STIR- Physics : Cold Atoms and Nanocrystals in Tapered Nanofiber...other than abstracts): Number of Peer-Reviewed Conference Proceeding publications (other than abstracts): Books Number of Manuscripts: 0.00Number of

  10. Jet impinging onto a laser drilled tapered hole: Influence of tapper location on heat transfer and skin friction at hole surface

    NASA Astrophysics Data System (ADS)

    Shuja, S. Z.; Yilbas, B. S.

    2013-02-01

    Jet emerging from a conical nozzle and impinging onto a tapered hole in relation to laser drilling is investigated and the influence taper location on the heat transfer and skin friction at the hole wall surface is examined. The study is extended to include four different gases as working fluid. The Reynolds stress model is incorporated to account for the turbulence effect in the flow field. The hole wall surface temperature is kept at 1500 K to resemble the laser drilled hole. It is found that the location of tapering in the hole influences the heat transfer rates and skin friction at the hole wall surface. The maximum skin friction coefficient increases for taper location of 0.25 H, where H is the thickness of the workpiece, while Nusselt number is higher in the hole for taper location of 0.75 H.

  11. Theoretical investigation for excitation light and fluorescence signal of fiber optical sensor using tapered fiber tip.

    PubMed

    Yuan, Yinquan; Ding, Liyun

    2011-10-24

    For fiber optical sensor made of tapered fiber tip, the effects of the geometrical parameters of tapered tip on two important factors have been investigated. One factor is the intensity of the evanescent wave into fluorescent layer through core-medium interface; the other is the intensity of fluorescence signal transmitted from fluorescent layer to measurement end. A dependence relation of the intensity of fluorescence signal transmitted from fluorescent layer to measurement end upon the geometrical parameters of tapered tip has been obtained. Theoretical results show that the intensity of the evanescent wave into fluorescent layer rises with the decrease of the end diameter of tapered tip, and the increase of the tip length; and the transmitted power of fluorescence signal increases linearly with the increase of the tip length due to the contribution of the side area of tapered tip. © 2011 Optical Society of America

  12. Pulse compression using a tapered microstructure optical fiber.

    PubMed

    Hu, Jonathan; Marks, Brian S; Menyuk, Curtis R; Kim, Jinchae; Carruthers, Thomas F; Wright, Barbara M; Taunay, Thierry F; Friebele, E J

    2006-05-01

    We calculate the pulse compression in a tapered microstructure optical fiber with four layers of holes. We show that the primary limitation on pulse compression is the loss due to mode leakage. As a fiber's diameter decreases due to the tapering, so does the air-hole diameter, and at a sufficiently small diameter the guided mode loss becomes unacceptably high. For the four-layer geometry we considered, a compression factor of 10 can be achieved by a pulse with an initial FWHM duration of 3 ps in a tapered fiber that is 28 m long. We find that there is little difference in the pulse compression between a linear taper profile and a Gaussian taper profile. More layers of air-holes allows the pitch to decrease considerably before losses become unacceptable, but only a moderate increase in the degree of pulse compression is obtained.

  13. Trial of Tocilizumab in Giant-Cell Arteritis.

    PubMed

    Stone, John H; Tuckwell, Katie; Dimonaco, Sophie; Klearman, Micki; Aringer, Martin; Blockmans, Daniel; Brouwer, Elisabeth; Cid, Maria C; Dasgupta, Bhaskar; Rech, Juergen; Salvarani, Carlo; Schett, Georg; Schulze-Koops, Hendrik; Spiera, Robert; Unizony, Sebastian H; Collinson, Neil

    2017-07-27

    Giant-cell arteritis commonly relapses when glucocorticoids are tapered, and the prolonged use of glucocorticoids is associated with side effects. The effect of the interleukin-6 receptor alpha inhibitor tocilizumab on the rates of relapse during glucocorticoid tapering was studied in patients with giant-cell arteritis. In this 1-year trial, we randomly assigned 251 patients, in a 2:1:1:1 ratio, to receive subcutaneous tocilizumab (at a dose of 162 mg) weekly or every other week, combined with a 26-week prednisone taper, or placebo combined with a prednisone taper over a period of either 26 weeks or 52 weeks. The primary outcome was the rate of sustained glucocorticoid-free remission at week 52 in each tocilizumab group as compared with the rate in the placebo group that underwent the 26-week prednisone taper. The key secondary outcome was the rate of remission in each tocilizumab group as compared with the placebo group that underwent the 52-week prednisone taper. Dosing of prednisone and safety were also assessed. Sustained remission at week 52 occurred in 56% of the patients treated with tocilizumab weekly and in 53% of those treated with tocilizumab every other week, as compared with 14% of those in the placebo group that underwent the 26-week prednisone taper and 18% of those in the placebo group that underwent the 52-week prednisone taper (P<0.001 for the comparisons of either active treatment with placebo). The cumulative median prednisone dose over the 52-week period was 1862 mg in each tocilizumab group, as compared with 3296 mg in the placebo group that underwent the 26-week taper (P<0.001 for both comparisons) and 3818 mg in the placebo group that underwent the 52-week taper (P<0.001 for both comparisons). Serious adverse events occurred in 15% of the patients in the group that received tocilizumab weekly, 14% of those in the group that received tocilizumab every other week, 22% of those in the placebo group that underwent the 26-week taper, and 25% of those in the placebo group that underwent the 52-week taper. Anterior ischemic optic neuropathy developed in one patient in the group that received tocilizumab every other week. Tocilizumab, received weekly or every other week, combined with a 26-week prednisone taper was superior to either 26-week or 52-week prednisone tapering plus placebo with regard to sustained glucocorticoid-free remission in patients with giant-cell arteritis. Longer follow-up is necessary to determine the durability of remission and safety of tocilizumab. (Funded by F. Hoffmann-La Roche; ClinicalTrials.gov number, NCT01791153 .).

  14. Gravitropism in Higher Plant Shoots 1

    PubMed Central

    Wheeler, Raymond M.; White, Rosemary G.; Salisbury, Frank B.

    1986-01-01

    Ethylene at 1.0 and 10.0 cubic centimeters per cubic meter decreased the rate of gravitropic bending in stems of cocklebur (Xanthium strumarium L.) and tomato (Lycopersicon esculentum Mill), but 0.1 cubic centimeter per cubic meter ethylene had little effect. Treating cocklebur plants with 1.0 millimolar aminoethoxyvinylglycine (AVG) (ethylene synthesis inhibitor) delayed stem bending compared with controls, but adding 0.1 cubic centimeter per cubic meter ethylene in the surrounding atmosphere (or applying 0.1% ethephon solution) partially restored the rate of bending of AVG-treated plants. Ethylene increases in bending stems, and AVG inhibits this. Virtually all newly synthesized ethylene appeared in bottom halves of horizontal stems, where ethylene concentrations were as much as 100 times those in upright stems or in top halves of horizontal stems. This was especially true when horizontal stems were physically restrained from bending. Ethylene might promote cell elongation in bottom tissues of a horizontal stem or indicate other factors there (e.g. a large amount of `functioning' auxin). Or top and bottom tissues may become differentially sensitive to ethylene. Auxin applied to one side of a vertical stem caused extreme bending away from that side; gibberellic acid, kinetin, and abscisic acid were without effect. Acidic ethephon solutions applied to one side of young seedlings of cocklebur, tomato, sunflower (Helianthus annuus L.), and soybean (Glycine max [L.] Merr.) caused bending away from that side, but neutral ethephon solutions did not cause bending. Buffered or unbuffered acid (HCl) caused similar bending. Neutral ethephon solutions produced typical ethylene symptoms (i.e. epinasty, inhibition of stem elongation). HCl or acidic ethephon applied to the top of horizontal stems caused downward bending, but these substances applied to the bottom of such stems inhibited growth and upward bending—an unexpected result. PMID:11539089

  15. Torque during canal instrumentation using rotary nickel-titanium files.

    PubMed

    Sattapan, B; Palamara, J E; Messer, H H

    2000-03-01

    Nickel-titanium engine-driven rotary instruments are used increasingly in endodontic practice. One frequently mentioned problem is fracture of an instrument in the root canal. Very few studies have been conducted on torsional characteristics of these instruments, and none has been done under dynamic conditions. The purposes of this study were to measure the torque generated and the apical force applied during instrumentation with a commercial engine-driven nickel-titanium file system, and to relate torque generated during simulated clinical use to torsional failure of the instruments. Ten extracted human teeth (five with small-sized and five with medium-sized straight root canals) were instrumented with Quantec Series 2000 files, and the torque and apical force generated were measured. The applied apical force was generally low, not exceeding 150 g in either small or medium canals. The torque depended on the tip size and taper of each instrument, and on canal size. Instruments with 0.05 and 0.06 taper generated the highest torque, which was greater in small than in medium canals. The torque at failure was significantly (p < 0.001) higher than torque during instrumentation, but with considerable variation in the extent of the difference.

  16. Fluids density functional theory and initializing molecular dynamics simulations of block copolymers

    NASA Astrophysics Data System (ADS)

    Brown, Jonathan R.; Seo, Youngmi; Maula, Tiara Ann D.; Hall, Lisa M.

    2016-03-01

    Classical, fluids density functional theory (fDFT), which can predict the equilibrium density profiles of polymeric systems, and coarse-grained molecular dynamics (MD) simulations, which are often used to show both structure and dynamics of soft materials, can be implemented using very similar bead-based polymer models. We aim to use fDFT and MD in tandem to examine the same system from these two points of view and take advantage of the different features of each methodology. Additionally, the density profiles resulting from fDFT calculations can be used to initialize the MD simulations in a close to equilibrated structure, speeding up the simulations. Here, we show how this method can be applied to study microphase separated states of both typical diblock and tapered diblock copolymers in which there is a region with a gradient in composition placed between the pure blocks. Both methods, applied at constant pressure, predict a decrease in total density as segregation strength or the length of the tapered region is increased. The predictions for the density profiles from fDFT and MD are similar across materials with a wide range of interfacial widths.

  17. Performance optimization of helicopter rotor blades

    NASA Technical Reports Server (NTRS)

    Walsh, Joanne L.

    1991-01-01

    As part of a center-wide activity at NASA Langley Research Center to develop multidisciplinary design procedures by accounting for discipline interactions, a performance design optimization procedure is developed. The procedure optimizes the aerodynamic performance of rotor blades by selecting the point of taper initiation, root chord, taper ratio, and maximum twist which minimize hover horsepower while not degrading forward flight performance. The procedure uses HOVT (a strip theory momentum analysis) to compute the horse power required for hover and the comprehensive helicopter analysis program CAMRAD to compute the horsepower required for forward flight and maneuver. The optimization algorithm consists of the general purpose optimization program CONMIN and approximate analyses. Sensitivity analyses consisting of derivatives of the objective function and constraints are carried out by forward finite differences. The procedure is applied to a test problem which is an analytical model of a wind tunnel model of a utility rotor blade.

  18. Density functional theory for hard uniaxial particles: Complex ordering of pear-shaped and spheroidal particles near a substrate

    NASA Astrophysics Data System (ADS)

    Schönhöfer, Philipp W. A.; Schröder-Turk, Gerd E.; Marechal, Matthieu

    2018-03-01

    We develop a density functional for hard particles with a smooth uniaxial shape (including non-inversion-symmetric particles) within the framework of fundamental measure theory. By applying it to a system of tapered, aspherical liquid-crystal formers, reminiscent of pears, we analyse their behaviour near a hard substrate. The theory predicts a complex orientational ordering close to the substrate, which can be directly related to the particle shape, in good agreement with our simulation results. Furthermore, the lack of particle inversion-symmetry implies the possibility of alternating orientations in subsequent layers as found in a smectic/lamellar phase of such particles. Both theory and Monte Carlo simulations confirm that such ordering occurs in our system. Our results are relevant for adsorption processes of asymmetric colloidal particles and molecules at hard interfaces and show once again that tapering strongly affects the properties of orientationally ordered phases.

  19. Tapering strategies in elite British endurance runners.

    PubMed

    Spilsbury, Kate L; Fudge, Barry W; Ingham, Stephen A; Faulkner, Steve H; Nimmo, Myra A

    2015-01-01

    The aim of the study was to explore pre-competition training practices of elite endurance runners. Training details from elite British middle distance (MD; 800 m and 1500 m), long distance (LD; 3000 m steeplechase to 10,000 m) and marathon (MAR) runners were collected by survey for 7 days in a regular training (RT) phase and throughout a pre-competition taper. Taper duration was [median (interquartile range)] 6 (3) days in MD, 6 (1) days in LD and 14 (8) days in MAR runners. Continuous running volume was reduced to 70 (16)%, 71 (24)% and 53 (12)% of regular levels in MD, LD and MAR runners, respectively (P < 0.05). Interval running volume was reduced compared to regular training (MD; 53 (45)%, LD; 67 (23)%, MAR; 64 (34)%, P < 0.05). During tapering, the peak interval training intensity was above race speed in LD and MAR runners (112 (27)% and 114 (3)%, respectively, P < 0.05), but not different in MD (100 (2)%). Higher weekly continuous running volume and frequency in RT were associated with greater corresponding reductions during the taper (R = -0.70 and R = -0.63, respectively, both P < 0.05). Running intensity during RT was positively associated with taper running intensity (continuous intensity; R = 0.97 and interval intensity; R = 0.81, both P < 0.05). Algorithms were generated to predict and potentially prescribe taper content based on the RT of elite runners. In conclusion, training undertaken prior to the taper in elite endurance runners is predictive of the tapering strategy implemented before competition.

  20. The effect of preparation taper on the retention of cemented cast crowns under lateral fatigue loading.

    PubMed

    Cameron, Stephen M; Morris, W Jack; Keesee, Stephen M; Barsky, Todd B; Parker, M Harry

    2006-06-01

    Clinicians have used resistance form as a basis for determining guidelines for preparation design to ensure clinical success of cemented cast restorations. Disagreement on whether clinical success follows the on-off or linear nature of resistance form continues. The purpose of this study was to evaluate the number of cycles required to dislodge a cemented complete crown casting under a cyclic lateral load as a function of taper and to compare this relationship for the resistive and nonresistive ranges of taper. Three dies were milled from stainless steel at each of the following tapers: 4, 8, 12, 16, 20, 24, 28, and 32 degrees. A gold-palladium metal-ceramic alloy crown was fabricated for each die, cemented, and subjected to lateral cyclic loading until failure or 1,000,000 cycles. The limiting taper for the dies with their given height and base was 26.6 degrees. Dies with taper less than 26.6 degrees had resistance form, whereas dies with taper larger than 26.6 degrees did not. A linear regression (alpha=.05) was used to evaluate the relation of cycles at dislodgement to taper. The average number of cycles to crown dislodgement or completion for each taper (SD), in units of 10,000, was as follows: 4 degrees, 100 (0); 8 degrees, 100 (0); 12 degrees, 93.54 (16.56); 16 degrees, 61.33 (38.47); 20 degrees, 25.73 (34.67); 24 degrees, 4.33 (7.36); 28 degrees, 0.06 (0.08); and 32 degrees, 0.05 (0.09). The crowns in the resistive area less than 26.6 degrees that demonstrated failure showed a linear regression with a correlation coefficient of -0.995 between the average number of cycles to dislodge the crown and the taper. The slope was significantly different from zero (P=.0048), with a value of -7.58 and a standard error of 0.53. The number of cycles required to cause crown dislodgement was linear after 12 degrees in the resistive area and nearly zero for preparations in the nonresistive area. The limiting taper concept closely predicted the transition point where the slope of the graph of cycles to dislodgement as a function of taper abruptly changed.

  1. Trapping and Propelling Microparticles at Long Range by Using an Entirely Stripped and Slightly Tapered No-Core Optical Fiber

    PubMed Central

    Sheu, Fang-Wen; Huang, Yen-Si

    2013-01-01

    A stripped no-core optical fiber with a 125 μm diameter was transformed into a symmetric and unbroken optical fiber that tapers slightly to a 45-μm-diameter waist. The laser light can be easily launched into the no-core optical fiber. The enhanced evanescent wave of the slightly tapered no-core optical fiber can attract nearby 5-μm-diameter polystyrene microparticles onto the surface of the tapered multimode optical fiber within fast flowing fluid and propel the trapped particles in the direction of the light propagation to longer delivery range than is possible using a slightly tapered telecom single-mode optical fiber. PMID:23449118

  2. Double-pass tapered amplifier diode laser with an output power of 1 W for an injection power of only 200 μW.

    PubMed

    Bolpasi, V; von Klitzing, W

    2010-11-01

    A 1 W tapered amplifier requiring only 200 μW of injection power at 780 nm is presented in this paper. This is achieved by injecting the seeding light into the amplifier from its tapered side and feeding the amplified light back into the small side. The amplified spontaneous emission of the tapered amplifier is suppressed by 75 dB. The double-passed tapered laser, presented here, is extremely stable and reliable. The output beam remains well coupled to the optical fiber for a timescale of months, whereas the injection of the seed light did not require realignment for over a year of daily operation.

  3. Characterized Brillouin scattering in silica optical fiber tapers based on Brillouin optical correlation domain analysis.

    PubMed

    Zou, Weiwen; Jiang, Wenning; Chen, Jianping

    2013-03-11

    This paper demonstrates stimulated Brillouin scattering (SBS) characterization in silica optical fiber tapers drawn from commercial single mode optical fibers by hydrogen flame. They have different waist diameters downscaled from 5 μm to 42 μm. The fully-distributed SBS measurement along the fiber tapers is implemented by Brillouin optical correlation domain analysis technique with millimeter spatial resolution. It is found that the Brillouin frequency shift (BFS) in the waist of all fiber tapers is approximately the same (i.e., ~11.17 GHz at 1550 nm). However, the BFS is gradually reduced and the Brillouin gain decreases from the waist to the untapered zone in each fiber taper.

  4. Using a slightly tapered optical fiber to attract and transport microparticles.

    PubMed

    Sheu, Fang-Wen; Wu, Hong-Yu; Chen, Sy-Hann

    2010-03-15

    We exploit a fiber puller to transform a telecom single-mode optical fiber with a 125 microm diameter into a symmetric and unbroken slightly tapered optical fiber with a 50 microm diameter at the minimum waist. When the laser light is launched into the optical fiber, we can observe that, due to the evanescent wave of the slightly tapered fiber, the nearby polystyrene microparticles with 10 microm diameters will be attracted onto the fiber surface and roll separately in the direction of light propagation. We have also simulated and compared the optical propulsion effects on the microparticles when the laser light is launched into a slightly tapered fiber and a heavily tapered (subwavelength) fiber, respectively.

  5. Measuring the charge density of a tapered optical fiber using trapped microparticles.

    PubMed

    Kamitani, Kazuhiko; Muranaka, Takuya; Takashima, Hideaki; Fujiwara, Masazumi; Tanaka, Utako; Takeuchi, Shigeki; Urabe, Shinji

    2016-03-07

    We report the measurements of charge density of tapered optical fibers using charged particles confined in a linear Paul trap at ambient pressure. A tapered optical fiber is placed across the trap axis at a right angle, and polystyrene microparticles are trapped along the trap axis. The distance between the equilibrium position of a positively charged particle and the tapered fiber is used to estimate the amount of charge per unit length of the fiber without knowing the amount of charge of the trapped particle. The charge per unit length of a tapered fiber with a diameter of 1.6 μm was measured to be 2-1+3×10 -11 C/m.

  6. Trapping and propelling microparticles at long range by using an entirely stripped and slightly tapered no-core optical fiber.

    PubMed

    Sheu, Fang-Wen; Huang, Yen-Si

    2013-02-28

    A stripped no-core optical fiber with a 125 µm diameter was transformed into a symmetric and unbroken optical fiber that tapers slightly to a 45-µm-diameter waist. The laser light can be easily launched into the no-core optical fiber. The enhanced evanescent wave of the slightly tapered no-core optical fiber can attract nearby 5-µm-diameter polystyrene microparticles onto the surface of the tapered multimode optical fiber within fast flowing fluid and propel the trapped particles in the direction of the light propagation to longer delivery range than is possible using a slightly tapered telecom single-mode optical fiber.

  7. Influence of resonance tube geometry shape on performance of thermoacoustic engine.

    PubMed

    Bao, Rui; Chen, Guobang; Tang, Ke; Jia, Zhengzhong; Cao, Weihua

    2006-12-22

    Based on the linear thermoacoustics, a symmetrical standing-wave thermoacoustic engine is simulated with a cylindrical tube and a tapered one as the resonance tube, respectively. The experiments with both cylindrical and tapered tubes are carried out. The suppression of nonlinear effects due to tapered tube as the resonance tube is discussed. Both simulation and experimental results show that the performance of the tapered tube is better than cylindrical one as the resonance tube.

  8. Fiber up-tapering and down-tapering for low-loss coupling between anti-resonant hollow-core fiber and solid-core fiber

    NASA Astrophysics Data System (ADS)

    Zhang, Naiqian; Wang, Zefeng; Xi, Xiaoming

    2017-10-01

    In this paper, we demonstrate a novel method for the low-loss coupling between solid-core multi-mode fibers (MMFs) and anti-resonant hollow-core fibers (AR-HCFs). The core/cladding diameter of the MMF is 50/125μm and the mode field diameter of the AR-HCFs are 33.3μm and 71.2μm of the ice-cream type AR-HCFs and the non-node type ARHCFs, respectively. In order to match the mode field diameters of these two specific AR-HCFs, the mode field diameter of the MMFs is increased or decreased by up-tapering or down-tapering the MMFs. Then, according to the principle of coupled fiber mode matching, the optimal diameter of tapered fiber for low-loss coupling is calculated. Based on beam propagation method, the calculated coupling losses without tapering process are 0.31dB and 0.89dB, respectively for a MMF-HCF-MMF structure of the ice-cream type AR-HCFs and the non-node type AR-HCFs. These values can be reduced to 0.096dB and 0.047dB when the outer diameters of the MMF are down-tapered to 116μm and up-tapered to 269μm, respectively. What's more, these results can also be verified by existing experiments.

  9. A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study

    PubMed Central

    Shankarappa, Pushpa; Misra, Abhinav; Sawhney, Asheesh; Sridevi, Nandamuri; Singh, Anu

    2016-01-01

    Introduction. The aim of the present study was to evaluate the dentinal cracks after root canal preparation with rotary files: Gates Glidden, ProTaper Universal, ProTaper Next, and HyFlex CM at different instrumentation lengths. Methodology. Sixty-five mandibular premolars were mounted in the acrylic tube with simulated periodontal ligaments and the apex was exposed. The root canals were instrumented with different rotary files, namely, ProTaper Universal, ProTaper Next, and HyFlex CM, to the major apical foramen (AF), short AF, and beyond AF. The root apex was stained with 1% methylene blue dye and digital images of apical surface of every tooth were taken and development of dentinal defects was determined by using stereomicroscope. Multinomial logistic regression test was performed to identify influencing factors. Results. Instrumentation with rotary files terminated 2 mm short AF and did not cause any cracks. Significantly less cracks were seen when instrumentation with rotary files terminated 1 mm short apical foramen when compared with the instrumentation terminated at or beyond apical foramen (p < 0.05). Conclusion. ProTaper Universal rotary files caused more dentinal cracks than ProTaper Next and HyFlex CM. Instrumentation short AF reduced the risk of dentinal defects. PMID:27446636

  10. Freeway work zone lane capacity.

    DOT National Transportation Integrated Search

    2009-01-01

    The focus of this report is a capacity analysis of two long-term urban freeway Work Zones. Work Zone #1 : tapered four mainline lanes to two, using two separate tapers; Work Zone #2 tapered two mainline lanes to one. : Work Zone throughput was analyz...

  11. Tapered structure construction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Eric D.; Takata, Rosalind K.; Slocum, Alexander H.

    Feeding stock used to form a tapered structure into a curving device such that each point on the stock undergoes rotational motion about a peak location of the tapered structure; and the stock meets a predecessor portion of stock along one or more adjacent edges.

  12. Comparative study of material loss at the taper interface in retrieved metal-on-polyethylene and metal-on-metal femoral components from a single manufacturer.

    PubMed

    Bills, Paul; Racasan, Radu; Bhattacharya, Saugatta; Blunt, Liam; Isaac, Graham

    2017-08-01

    There have been a number of reports on the occurrence of taper corrosion and/or fretting and some have speculated on a link to the occurrence of adverse local tissue reaction specifically in relation to total hip replacement which have a metal-on-metal bearing. As such a study was carried out to compare the magnitude of material loss at the taper in a series of retrieved femoral heads used in metal-on-polyethylene bearings with that in a series of retrieved heads used in metal-on-metal bearings. A total of 36 metal-on-polyethylene and 21 metal-on-metal femoral components were included in the study all of which were received from a customer complaint database. Furthermore, a total of nine as-manufactured femoral components were included to provide a baseline for characterisation. All taper surfaces were assessed using an established corrosion scoring method and measurements were taken of the female taper surface using a contact profilometry. In the case of metal-on-metal components, the bearing wear was also assessed using coordinate metrology to determine whether or not there was a relationship between bearing and taper material loss in these cases. The study found that in this cohort the median value of metal-on-polyethylene taper loss was 1.25 mm 3 with the consequent median value for metal-on-metal taper loss being 1.75 mm 3 . This study also suggests that manufacturing form can result in an apparent loss of material from the taper surface determined to have a median value of 0.59 mm 3 . Therefore, it is clear that form variability is a significant confounding factor in the measurement of material loss from the tapers of femoral heads retrieved following revision surgery.

  13. A combined paging alert and web-based instrument alters clinician behavior and shortens hospital length of stay in acute pancreatitis.

    PubMed

    Dimagno, Matthew J; Wamsteker, Erik-Jan; Rizk, Rafat S; Spaete, Joshua P; Gupta, Suraj; Sahay, Tanya; Costanzo, Jeffrey; Inadomi, John M; Napolitano, Lena M; Hyzy, Robert C; Desmond, Jeff S

    2014-03-01

    There are many published clinical guidelines for acute pancreatitis (AP). Implementation of these recommendations is variable. We hypothesized that a clinical decision support (CDS) tool would change clinician behavior and shorten hospital length of stay (LOS). Observational study, entitled, The AP Early Response (TAPER) Project. Tertiary center emergency department (ED) and hospital. Two consecutive samplings of patients having ICD-9 code (577.0) for AP were generated from the emergency department (ED) or hospital admissions. Diagnosis of AP was based on conventional Atlanta criteria. The Pre-TAPER-CDS-Tool group (5/30/06-6/22/07) had 110 patients presenting to the ED with AP per 976 ICD-9 (577.0) codes and the Post-TAPER-CDS-Tool group (5/30/06-6/22/07) had 113 per 907 ICD-9 codes (7/14/10-5/5/11). The TAPER-CDS-Tool, developed 12/2008-7/14/2010, is a combined early, automated paging-alert system, which text pages ED clinicians about a patient with AP and an intuitive web-based point-of-care instrument, consisting of seven early management recommendations. The pre- vs. post-TAPER-CDS-Tool groups had similar baseline characteristics. The post-TAPER-CDS-Tool group met two management goals more frequently than the pre-TAPER-CDS-Tool group: risk stratification (P<0.0001) and intravenous fluids >6L/1st 0-24 h (P=0.0003). Mean (s.d.) hospital LOS was significantly shorter in the post-TAPER-CDS-Tool group (4.6 (3.1) vs. 6.7 (7.0) days, P=0.0126). Multivariate analysis identified four independent variables for hospital LOS: the TAPER-CDS-Tool associated with shorter LOS (P=0.0049) and three variables associated with longer LOS: Japanese severity score (P=0.0361), persistent organ failure (P=0.0088), and local pancreatic complications (<0.0001). The TAPER-CDS-Tool is associated with changed clinician behavior and shortened hospital LOS, which has significant financial implications.

  14. Guided-Mode-Leaky-Mode-Guided-Mode Fiber Interferometer and Its High Sensitivity Refractive Index Sensing Technology.

    PubMed

    Wang, Qi; Li, Chunyue; Zhao, Chengwu; Li, Weizheng

    2016-06-01

    A cascaded symmetrical dual-taper Mach-Zehnder interferometer structure based on guided-mode and leaky-mode interference is proposed in this paper. Firstly, the interference spectrum characteristics of interferometer has been analyzed by the Finite Difference-Beam Propagation Method (FD-BPM). When the diameter of taper waist is 20 μm-30 μm, dual-taper length is 1 mm and taper distance is 4 cm-6 cm, the spectral contrast is higher, which is suitable for sensing. Secondly, experimental research on refractive index sensitivity is carried out. A refractive index sensitivity of 62.78 nm/RIU (refractive index unit) can achieved in the RI range of 1.3333-1.3792 (0%~25% NaCl solution), when the sensor structure parameters meet the following conditions: diameter of taper waist is 24 μm, dual-taper length is 837 μm and taper distance is 5.5 cm. The spectrum contrast is 0.8 and measurement resolution is 1.6 × 10(-5) RIU. The simulation analysis is highly consistent with experimental results. Research shows that the sensor has promising application in low RI fields where high-precision measurement is required due to its high sensitivity and stability.

  15. Modeling and simulation performance of sucker rod beam pump

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aditsania, Annisa, E-mail: annisaaditsania@gmail.com; Rahmawati, Silvy Dewi, E-mail: silvyarahmawati@gmail.com; Sukarno, Pudjo, E-mail: psukarno@gmail.com

    2015-09-30

    Artificial lift is a mechanism to lift hydrocarbon, generally petroleum, from a well to surface. This is used in the case that the natural pressure from the reservoir has significantly decreased. Sucker rod beam pumping is a method of artificial lift. Sucker rod beam pump is modeled in this research as a function of geometry of the surface part, the size of sucker rod string, and fluid properties. Besides its length, sucker rod string also classified into tapered and un-tapered. At the beginning of this research, for easy modeling, the sucker rod string was assumed as un-tapered. The assumption provedmore » non-realistic to use. Therefore, the tapered sucker rod string modeling needs building. The numerical solution of this sucker rod beam pump model is computed using finite difference method. The numerical result shows that the peak of polished rod load for sucker rod beam pump unit C-456-D-256-120, for non-tapered sucker rod string is 38504.2 lb, while for tapered rod string is 25723.3 lb. For that reason, to avoid the sucker rod string breaks due to the overload, the use of tapered sucker rod beam string is suggested in this research.« less

  16. Polymer taper bridge for silicon waveguide to single mode waveguide coupling

    NASA Astrophysics Data System (ADS)

    Kruse, Kevin; Middlebrook, Christopher T.

    2016-03-01

    Coupling of optical power from high-density silicon waveguides to silica optical fibers for signal routing can incur high losses and often requires complex end-face preparation/processing. Novel coupling device taper structures are proposed for low coupling loss between silicon photonic waveguides and single mode fibers are proposed and devices are fabricated and measured in terms of performance. Theoretical mode conversion models for waveguide tapers are derived for optimal device structure design and performance. Commercially viable vertical and multi-layer taper designs using polymer waveguide materials are proposed as innovative, cost-efficient, and mass-manufacturable optical coupling devices. The coupling efficiency for both designs is determined to evaluate optimal device dimensions and alignment tolerances with both silicon rib waveguides and silicon nanowire waveguides. Propagation loss as a function of waveguide roughness and metallic loss are determined and correlated to waveguide dimensions to obtain total insertion loss for the proposed taper designs. Multi-layer tapers on gold-sputtered substrates are fabricated through photolithography as proof-of-concept devices and evaluated for device loss optimization. Tapered waveguide coupling loss with Si WGs (2.74 dB) was experimentally measured with high correlation to theoretical results.

  17. Gravitropism in Leafy Dicot Stems

    NASA Technical Reports Server (NTRS)

    Salisbury, F. B.

    1985-01-01

    A polarizing research microscope with rotating stage and associated camera equipment were ordered, and techniques of fixation and preparation of specimens were perfected for studying possible changes in orientation of cellulose microfibrils in cell walls of gravistimulated dicot stems. Acid ethephon solutions or acid without ethephon caused elongation of stem tissues where they were applied; stems bent away from the side of application. Acid solutions applied to the bottom of horizontal stems greatly delayed bending. Research in tissue sensitivity changes during gravitropic bending of soybean hypocotyls while immersed in auxin and in castor bean stems is also reported.

  18. 5 CFR 353.303 - Restoration rights of TAPER employees.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Restoration rights of TAPER employees... Restoration rights of TAPER employees. An employee serving in the competitive service under a temporary... she left or an equivalent one in the same commuting area. ...

  19. Merging taper lengths for short duration lane closure : final report, December 2009.

    DOT National Transportation Integrated Search

    2009-12-01

    The Utility Industry has requested that the Florida Department of Transportation provide for the use of merging taper lengths that are significantly shorter than the lengths computed using the taper length equations published in the MUTCD Section 6C....

  20. Red-green-blue (RGB) light generator using tapered fiber pumped with a frequency-doubled Yb-fiber laser.

    PubMed

    Rusu, M; Kivistö, Samuli; Gawith, C; Okhotnikov, O

    2005-10-17

    We report on successful realization of a picosecond visible-continuum source embedding a single mode fiber taper. The output of ytterbium mode-locked fiber laser was frequency doubled in a periodically-polled lithium niobate (PPLN) crystal to produce green pump light. Spectral brightness of the white light generated in the tapered fiber was improved by limiting the broadening just to the visible wavelengths. The influence of taper parameters, particularly the dispersion, on white light spectrum has been studied.

  1. Red-green-blue (RGB) light generator using tapered fiber pumped with a frequency-doubled Yb-fiber laser

    NASA Astrophysics Data System (ADS)

    Rusu, M.; Kivistö, Samuli; Gawith, C. B. E.; Okhotnikov, O. G.

    2005-10-01

    We report on successful realization of a picosecond visible-continuum source embedding a single mode fiber taper. The output of ytterbium mode-locked fiber laser was frequency doubled in a periodically-polled lithium niobate (PPLN) crystal to produce green pump light. Spectral brightness of the white light generated in the tapered fiber was improved by limiting the broadening just to the visible wavelengths. The influence of taper parameters, particularly the dispersion, on white light spectrum has been studied.

  2. Experimental design rules for implementing biconically tapered single mode optical fibre displacement sensors

    NASA Astrophysics Data System (ADS)

    Arregui, Francisco J.; Matias, Ignacio R.; Bariain, Candido; Lopez-Amo, Manuel

    1998-06-01

    Tapered optical fibers are used to design couplers, wavelength division multiplexers, near field scanning optical microscopy, just to mention a few. Moreover, and due to its strong transmission dependence to external medium the tapered fiber may also be used to sense distinct parameters such as temperature, humidity, PH, etc. In this work bending effects in tapers are exploited to achieved displacement sensors and to present design rules for implementing these sensors according to the desired both range and sensitivity.

  3. Fabrication of longitudinally arbitrary shaped fiber tapers

    NASA Astrophysics Data System (ADS)

    Nold, J.; Plötner, M.; Böhme, S.; Sattler, B.; deVries, O.; Schreiber, T.; Eberhardt, R.; Tünnermann, A.

    2018-02-01

    We present our current results on the fabrication of arbitrary shaped fiber tapers on our tapering rig using a CO2-laser as heat source. Single mode excitation of multimode fibers as well as changing the fiber geometry in an LPG-like fashion is presented. It is shown that this setup allows for reproducible fabrication of single-mode excitation tapers to extract the fundamental mode (M2 < 1.1) from a 30 μm core having an NA of 0.09.

  4. Tapered undulator for SASE FELs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fawley, William M.; Huang, Zhirong; Kim, Kwang-Je

    We discuss the use of tapered undulators to enhance the performance of free-electron lasers (FELs) based upon self-amplified spontaneous emission (SASE), where the radiation tends to have a relatively broad bandwidth, limited temporal phase coherence, and large amplitude fluctuations. Using the polychromatic FEL simulation code GINGER, we numerically demonstrate the effectiveness of a tapered undulator for parameters corresponding to the existing Argonne low-energy undulator test line (LEUTL) FEL. We also study possible tapering options for proposed x-ray FELs such as the Linac Coherent Light Source (LCLS).

  5. Does Applied STEM Course Taking Link to STEM Outcomes for High School Students with Learning Disabilities?

    ERIC Educational Resources Information Center

    Gottfried, Michael A.; Sublett, Cameron

    2018-01-01

    Over the most recent two decades, federal policy has urged high schools to embed applied science, technology, engineering, and mathematics (STEM) courses into the curriculum to reinforce concepts learned in traditional math and science classes as well as to motivate students' interests and long-term pursuits in STEM areas. While prior research has…

  6. Effect of Instrumentation Techniques and Preparation Taper on Apical Extrusion of Bacteria.

    PubMed

    Aksel, Hacer; Küçükkaya Eren, Selen; Çakar, Aslı; Serper, Ahmet; Özkuyumcu, Cumhur; Azim, Adham A

    2017-06-01

    The aim of this in vitro study was to evaluate the effects of different root canal instrumentation techniques and preparation tapers on the amount of apically extruded bacteria. The root canals of 98 extracted human mandibular incisors were contaminated with Enterococcus faecalis suspension. After incubation at 37°C for 24 hours, the root canals were instrumented with K3 rotary files in a crown-down (CD) or full-length linear instrumentation technique (FL) by using 3 different root canal tapers (0.02, 0.04, and 0.06). During instrumentation, apically extruded bacteria were collected into vials containing saline solution. The microbiological samples were taken from the vials and incubated in brain-heart agar medium for 24 hours, and the numbers of colony-forming units (CFUs) were determined. The obtained results were analyzed with t test and one-way analysis of variance for the comparisons between the instrumentation techniques (CD and FL) and the preparation tapers (0.02, 0.04, and 0.06), respectively. Tukey honestly significant difference test was used for pairwise comparisons. The preparation taper had no effect on the number of CFUs when a FL instrumentation technique was used (P > .05). There was a statistically significant difference in the CFUs between FL and CD techniques when the preparation taper was 0.02 (P < .05). There was no statistically significant difference between the 0.04 and 0.06 preparation tapers in any of the instrumentation techniques (P > .05). Using a 0.02 taper in a CD manner results in the least amount of bacterial extrusion. The instrumentation technique did not seem to affect the amount of bacterial extrusion when 0.04 and 0.06 taper instruments were used for cleaning and shaping the root canal space. Published by Elsevier Inc.

  7. Energy partitioning and impulse dispersion in the decorated, tapered, strongly nonlinear granular alignment: A system with many potential applications

    NASA Astrophysics Data System (ADS)

    Doney, Robert L.; Agui, Juan H.; Sen, Surajit

    2009-09-01

    Rapid absorption of impulses using light-weight, small, reusable systems is a challenging problem. An axially aligned set of progressively shrinking elastic spheres, a "tapered chain," has been shown to be a versatile and scalable shock absorber in earlier simulational, theoretical, and experimental works by several authors. We have recently shown (see R. L. Doney and S. Sen, Phys. Rev. Lett. 97, 155502 (2006)) that the shock absorption ability of a tapered chain can be dramatically enhanced by placing small interstitial grains between the regular grains in the tapered chain systems. Here we focus on a detailed study of the problem introduced in the above mentioned letter, present extensive dynamical simulations using parameters for a titanium-aluminum-vanadium alloy Ti6Al4V, derive attendant hard-sphere analyses based formulae to describe energy dispersion, and finally discuss some preliminary experimental results using systems with chrome spheres and small Nitinol interstitial grains to present the underlying nonlinear dynamics of this so-called decorated tapered granular alignment. We are specifically interested in small systems, comprised of several grains. This is because in real applications, mass and volume occupied must inevitably be minimized. Our conclusion is that the decorated tapered chain offers enhanced energy dispersion by locking in much of the input energy in the grains of the tapered chain rather than in the small interstitial grains. Thus, the present study offers insights into how the shock absorption capabilities of these systems can be pushed even further by improving energy absorption capabilities of the larger grains in the tapered chains. We envision that these scalable, decorated tapered chains may be used as shock absorbing components in body armor, armored vehicles, building applications and in perhaps even in applications in rehabilitation science.

  8. Chirped self-similar optical pulses in tapered centrosymmetric nonlinear waveguides doped with resonant impurities

    NASA Astrophysics Data System (ADS)

    He, J. R.; Xu, S. L.; Xue, L.

    2017-11-01

    Exact chirped self-similar optical pulses propagating in tapered centrosymmetric nonlinear waveguides doped with resonant impurities are reported. The propagation behaviors of the pulses are studied by tailoring of the tapering function. Numerical simulations and stability analysis reveal that the tapering can be used to postpone the wave dispersion and the addition of a small cubic self-focusing term to the governing equation could stabilize the chirped bright pulses. An example of possible experimental protocol that may generate the pulses in realistic waveguides is given. The obtained chirped self-similar optical pulses are particularly useful in the design of amplifying or attenuating pulse compressors for chirped solitary waves in tapered centrosymmetric nonlinear waveguides doped with resonant impurities.

  9. Adiabatic tapered optical fiber fabrication in two step etching

    NASA Astrophysics Data System (ADS)

    Chenari, Z.; Latifi, H.; Ghamari, S.; Hashemi, R. S.; Doroodmand, F.

    2016-01-01

    A two-step etching method using HF acid and Buffered HF is proposed to fabricate adiabatic biconical optical fiber tapers. Due to the fact that the etching rate in second step is almost 3 times slower than the previous droplet etching method, terminating the fabrication process is controllable enough to achieve a desirable fiber diameter. By monitoring transmitted spectrum, final diameter and adiabaticity of tapers are deduced. Tapers with losses about 0.3 dB in air and 4.2 dB in water are produced. The biconical fiber taper fabricated using this method is used to excite whispering gallery modes (WGMs) on a microsphere surface in an aquatic environment. So that they are suitable to be used in applications like WGM biosensors.

  10. Tapered fluorotellurite microstructured fibers for broadband supercontinuum generation.

    PubMed

    Wang, Fang; Wang, Kangkang; Yao, Chuanfei; Jia, Zhixu; Wang, Shunbin; Wu, Changfeng; Qin, Guanshi; Ohishi, Yasutake; Qin, Weiping

    2016-02-01

    Fluorotellurite microstructured fibers (MFs) based on TeO2-BaF2-Y2O3 glasses are fabricated by using a rod-in-tube method. Tapered fluorotellurite MFs with varied transition region lengths are prepared by employing an elongation machine. By using a tapered fluorotellurite MF with a transition region length of ∼3.3  cm as the nonlinear medium and a 1560 nm femtosecond fiber laser as the pump source, broadband supercontinuum generation covering from 470 to 2770 nm is obtained. The effects of the transition region length of the tapered fluorotellurite MF on supercontinuum generation are also investigated. Our results show that tapered fluorotellurite MFs are promising nonlinear media for generating broadband supercontinuum light expanding from visible to mid-infrared spectral region.

  11. Tapered GRIN fiber microsensor.

    PubMed

    Beltrán-Mejía, Felipe; Biazoli, Claudecir R; Cordeiro, Cristiano M B

    2014-12-15

    The sensitivity of an optical fiber microsensor based on inter-modal interference can be considerably improved by tapering a short extension of the multimode fiber. In the case of Graded Index fibers with a parabolic refractive index profile, a meridional ray exhibits a sinusoidal path. When these fibers are tapered, the period of the propagated beam decrease down-taper and increase up-taper. We take advantage of this modulation -along with the enhanced overlap between the evanescent field and the external medium- to substantially increase the sensitivity of these devices by tuning the sensor's maximum sensitivity wavelength. Moreover, the extension of this device is reduced by one order of magnitude, making it more propitious for reduced space applications. Numerical and experimental results demonstrate the success and feasibility of this approach.

  12. Tapered fiber based high power random laser.

    PubMed

    Zhang, Hanwei; Du, Xueyuan; Zhou, Pu; Wang, Xiaolin; Xu, Xiaojun

    2016-04-18

    We propose a novel high power random fiber laser (RFL) based on tapered fiber. It can overcome the power scaling limitation of RFL while maintaining good beam quality to a certain extent. An output power of 26.5 W has been achieved in a half-open cavity with one kilometer long tapered fiber whose core diameter gradually changes from 8 μm to 20 μm. The steady-state light propagation equations have been modified by taking into account the effective core area to demonstrate the tapered RFL through numerical calculations. The numerical model effectively describes the power characteristics of the tapered fiber based RFL, and both the calculating and experimental results show higher power exporting potential compared with the conventional single mode RFL.

  13. How Does Applied STEM Coursework Relate to Mathematics and Science Self-Efficacy among High School Students? Evidence from a National Sample

    ERIC Educational Resources Information Center

    Sublett, Cameron; Plasman, Jay Stratte

    2017-01-01

    Over the past decade, CTE has been highlighted as a means of promoting college and career readiness for high school students. Applied STEM coursework is a promising area of high school study that has particular relevance in the technologically progressive world of today. Previous research has illustrated that applied STEM coursework in high school…

  14. Quantitative evaluation of apically extruded debris during root canal instrumentation with ProTaper Universal, ProTaper Next, WaveOne, and self-adjusting file systems

    PubMed Central

    Ozsu, Damla; Karatas, Ertugrul; Arslan, Hakan; Topcu, Meltem C.

    2014-01-01

    Objectives: The aim of this study was to compare the amount of apically extruded debris during preparation with ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Next (Dentsply Maillefer), a reciprocating single-file (WaveOne; VDW GmbH, Munich, Germany), and a self-adjusting file (SAF; ReDent Nova, Ra’anna, Israel). Materials and Methods: Fifty-six intact mandibular premolar teeth were randomly assigned to four groups. The root canals were prepared according to the manufacturers’ instructions using the ProTaper Universal, ProTaper Next, WaveOne, and SAF. Apically extruded debris was collected in preweighted Eppendorf tubes during instrumentation. The net weight of the apically extruded debris was determined by subtracting the preweights and postweights of the tubes. The data were statistically analyzed using the one-way analysis of variance and the least significant difference tests at a significance level of P < 0.05. Results: A measurable amount of debris was apically extruded in all groups, and the amounts of debris extrusion in the groups were statistically significant (P < 0.001). The ProTaper Next and WaveOne groups resulted in less debris extrusion than the ProTaper Universal group (P < 0.05), and the SAF group resulted in the least debris extrusion. Conclusions: Within the limitations of the present study, it can be concluded that all systems extruded debris beyond the apical foramen. PMID:25512732

  15. Effect of blade planform variation on the forward-flight performance of small-scale rotors

    NASA Technical Reports Server (NTRS)

    Noonan, Kevin W.; Althoff, Susan L.; Samak, Dhananjay K.; Green, Michael D.

    1992-01-01

    An investigation was conducted in the Glenn L. Martin Wind Tunnel to determine the effect of blade planform variation on the forward-flight performance of four small-scale rotors. The rotors were 5.417 ft in diameter and differed only in blade planform geometry. The four planforms were: (1) rectangular; (2) 3:1 linear taper starting at 94 percent radius; (3) 3:1 linear taper starting at 75 percent radius; and (4) 3:1 linear taper starting at 50 percent radius. Each planform had a thrust-weighted solidity of 0.098. The investigation included forward-flight simulation at advance ratios from 0.14 to 0.43 for a range of rotor lift and drag coefficients. Among the four rotors, the rectangular rotor required the highest torque for the entire range of rotor drag coefficients attained at advanced ratios greater than 0.14 for rotor lift coefficients C sub L from 0.004 to 0.007. Among the rotors with tapered blades and for C sub L = 0.004 to 0.007, either the 75 percent tapered rotor or the 50 percent tapered rotor required the least amount of torque for the full range of rotor drag coefficients attained at each advance ratio. The performance of the 94 percent tapered rotor was generally between that of the rectangular rotor and the 75 and 50 percent tapered rotors at each advance ratio for this range of rotor lift coefficients.

  16. Mechanics of the taper integrated screwed-in (TIS) abutments used in dental implants.

    PubMed

    Bozkaya, Dinçer; Müftü, Sinan

    2005-01-01

    The tapered implant-abutment interface is becoming more popular due to the mechanical reliability of retention it provides. Consequently, understanding the mechanical properties of the tapered interface with or without a screw at the bottom has been the subject of a considerable amount of studies involving experiments and finite element (FE) analysis. This paper focuses on the tapered implant-abutment interface with a screw integrated at the bottom of the abutment. The tightening and loosening torques are the main factors in determining the reliability and the stability of the attachment. Analytical formulas are developed to predict tightening and loosening torque values by combining the equations related to the tapered interface with screw mechanics equations. This enables the identification of the effects of the parameters such as friction, geometric properties of the screw, the taper angle, and the elastic properties of the materials on the mechanics of the system. In particular, a relation between the tightening torque and the screw pretension is identified. It was shown that the loosening torque is smaller than the tightening torque for typical values of the parameters. Most of the tightening load is carried by the tapered section of the abutment, and in certain combinations of the parameters the pretension in the screw may become zero. The calculations performed to determine the loosening torque as a percentage of tightening torque resulted in the range 85-137%, depending on the values of taper angle and the friction coefficient.

  17. Supercompensation Kinetics of Physical Qualities During a Taper in Team-Sport Athletes.

    PubMed

    Marrier, Bruno; Robineau, Julien; Piscione, Julien; Lacome, Mathieu; Peeters, Alexis; Hausswirth, Christophe; Morin, Jean-Benoît; Le Meur, Yann

    2017-10-01

    Peaking for major competition is considered critical for maximizing team-sport performance. However, there is little scientific information available to guide coaches in prescribing efficient tapering strategies for team-sport players. To monitor the changes in physical performance in elite team-sport players during a 3-wk taper after a preseason training camp. Ten male international rugby sevens players were tested before (Pre) and after (Post) a 4-wk preseason training camp focusing on high-intensity training and strength training with moderate loads and once each week during a subsequent 3-wk taper. During each testing session, midthigh-pull maximal strength, sprint-acceleration mechanical outputs, and performance, as well as repeated-sprint ability (RSA), were assessed. At Post, no single peak performance was observed for maximal lower-limb force output and sprint performance, while RSA peaked for only 1 athlete. During the taper, 30-m-sprint time decreased almost certainly (-3.1% ± 0.9%, large), while maximal lower-limb strength and RSA, respectively, improved very likely (+7.7% ± 5.3%, small) and almost certainly (+9.0% ± 2.6%, moderate). Of the peak performances, 70%, 80%, and 80% occurred within the first 2 wk of taper for RSA, maximal force output, and sprint performance, respectively. These results show the sensitivity of physical qualities to tapering in rugby sevens players and suggest that an ~1- to 2-wk tapering time frame appears optimal to maximize the overall physical-performance response.

  18. An In vitro Comparison of Apically Extruded Debris Using Reciproc, ProTaper Universal, Neolix and Hyflex in Curved Canals.

    PubMed

    Labbaf, Hossein; Nazari Moghadam, Kiumars; Shahab, Shahriar; Mohammadi Bassir, Mahshid; Fahimi, Mohammad Amin

    2017-01-01

    As a consequence of root canal preparation, dentinal chips, irrigants and pulp remnants are extruded into preradicular space. This phenomenon may lead to post endodontic flare-ups. The purpose of this study was to compare the amount of extruded debris with four endodontic NiTi engine-driven systems. Sixty mesiobuccal roots of maxillary molars with 15-30˚ curvature were divided randomly into four groups ( n =15). Each group was instrumented up to apical size of 25 using Reciproc, ProTaper Universal, Neolix and Hyflex. Bidistilled water was used as irrigant and extruded debris was collected in pre-weighted Eppendorf tubes. Tubes were stored in incubator for drying the debris. Extruded debris were weighted in electronic microbalance with accuracy of 0.0001 g. The raw data was analyzed with one way analysis of variance (ANOVA) and Tukey's HSD post hoc test. Level of significance was set at 0.05. The debris extrusion with Reciproc files was significantly higher than the other groups ( P <0.05). Hyflex significantly extruded less debris than other files ( P <0.05). There was no significant difference between ProTaper Universal and Neolix regarding the amount of extruded debris ( P =0.98). All systems extruded debris during the instrumentation. Reciproc system significantly extruded more debris. Caution should be taken when interpreting the results of this study and applying it to the real clinical situation.

  19. High-temperature, high-pressure bonding of nested tubular metallic components

    DOEpatents

    Quinby, T.C.

    A tool is described for effecting high-temperature, high-compression bonding between the confronting faces of nested, tubular, metallic components. In a typical application, the tool is used to produce tubular target assemblies for irradiation in nuclear reactors or particle accelerators. The target assembly comprising a uranum foil and an aluninum-alloy substrate. The tool is composed of graphite. It comprises a tubular restraining member in which a mechanically expandable tubular core is mounted to form an annulus. The components to be bonded are mounted in nested relation in the annulus. The expandable core is formed of individually movable, axially elongated segments whose outer faces cooperatively define a cylindrical pressing surface and whose inner faces cooperatively define two opposed, inwardly tapered, axial bores. Tapered rams extend into the bores. The loaded tool is mounted in a conventional hot-press provided with evacuation means, heaters for maintaining its interior at bonding temperature, and hydraulic cylinders for maintaining a selected inwardly directed pressure on the tapered rams. With the hot-press evacuated and the loaded tool at the desired temperature, the cylinders are actuated to apply the selected pressure to the rams. The rams in turn expand the segmented core to maintain the nested components in compression against the restraining member. These conditions are maintained until the confronting faces of the nested components are joined in a continuous, uniform bond characterized by high thermal conductivity.

  20. Catalog of Window Taper Functions for Sidelobe Control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doerry, Armin W.

    Window taper functions of finite apertures are well-known to control undesirable sidelobes, albeit with performance trades. A plethora of various taper functions have been developed over the years to achieve various optimizations. We herein catalog a number of window functions, and com pare principal characteristics.

  1. Load Fatigue Performance Evaluation on Two Internal Tapered Abutment-Implant Connection Implants Under Different Screw Tightening Torques.

    PubMed

    Jeng, Ming-Dih; Liu, Po-Yi; Kuo, Jia-Hum; Lin, Chun-Li

    2017-04-01

    This study evaluates the load fatigue performance of different abutment-implant connection implant types-retaining-screw (RS) and taper integrated screwed-in (TIS) types under 3 applied torque levels based on the screw elastic limit. Three torque levels-the recommended torque (25 Ncm), 10% less, and 10% more than the ratio of recommended torque to screw elastic limits of different implants were applied to the implants to perform static and dynamic testing according to the ISO 14801 method. Removal torque loss was calculated for each group after the endurance limitation was reached (passed 5 × 10 6 cycles) in the fatigue test. The static fracture resistance results showed that the fracture resistance in the TIS-type implant significantly increased (P < .05) when the abutment screw was inserted tightly. The dynamic testing results showed that the endurance limitations for the RS-type implant were 229 N, 197 N, and 224 N and those for the TIS-type implant were 322 N, 364 N, and 376 N when the screw insertion torques were applied from low to high. The corresponding significant (P < .05) removal torque losses for the TIS-type implant were 13.2%, 5.3%, and 2.6% but no significant difference was found for the RS-type implant. This study concluded that the static fracture resistance and dynamic endurance limitation of the TIS-type implant (1-piece solid abutment) increased when torque was applied more tightly on the screw. Less torque loss was also found when increasing the screw insertion torque.

  2. 77 FR 12326 - Tapered Roller Bearings From China; Scheduling of a Full Five-Year Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-29

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-344 (Third Review)] Tapered Roller Bearings From China; Scheduling of a Full Five- Year Review AGENCY: United States International Trade... whether revocation of the antidumping duty order on tapered roller bearings from China would be likely to...

  3. 77 FR 45587 - Tapered Roller Bearings and Parts Thereof, Finished and Unfinished, from the People's Republic of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-01

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-601] Tapered Roller Bearings and... new shipper review (``NSR'') of the antidumping duty order on tapered roller bearings (``TRBs'') from... from Zhejiang Zhengda Bearing Co., Ltd. (``Zhejiang Zhengda''). Zhejiang Zhengda's request was made in...

  4. Free torsional vibrations of tapered cantilever I-beams

    NASA Astrophysics Data System (ADS)

    Rao, C. Kameswara; Mirza, S.

    1988-08-01

    Torsional vibration characteristics of linearly tapered cantilever I-beams have been studied by using the Galerkin finite element method. A third degree polynomial is assumed for the angle of twist. The analysis presented is valid for long beams and includes the effect of warping. The individual as well as combined effects of linear tapers in the width of the flanges and the depth of the web on the torsional vibration of cantilever I-beams are investigated. Numerical results generated for various values of taper ratios are presented in graphical form.

  5. CORROSION RESISTANT JACKETED METAL BODY

    DOEpatents

    Brugmann, E.W.

    1958-08-26

    Jacketed metal bodies of the type used as fuel elements for nuclear reactors, which contain an internal elongated body of fissionable material jacketed in a corrosion resistant metal are described. The ends of the internal bodies are provided with screw threads having a tapered outer end. The jacket material overlaps the ends and extends into the tapered section of the screw threaded opening. Screw caps with a mating tapered section are screwed into the ends of the body to compress the jacket material in the tapered sections to provtde an effective seal against corrosive gases and liquids.

  6. Racetrack resonator as a loss measurement platform for photonic components.

    PubMed

    Jones, Adam M; DeRose, Christopher T; Lentine, Anthony L; Starbuck, Andrew; Pomerene, Andrew T S; Norwood, Robert A

    2015-11-02

    This work represents the first complete analysis of the use of a racetrack resonator to measure the insertion loss of efficient, compact photonic components. Beginning with an in-depth analysis of potential error sources and a discussion of the calibration procedure, the technique is used to estimate the insertion loss of waveguide width tapers of varying geometry with a resulting 95% confidence interval of 0.007 dB. The work concludes with a performance comparison of the analyzed tapers with results presented for four taper profiles and three taper lengths.

  7. Non-lead hollow point bullet

    DOEpatents

    Vaughn, Norman L.; Lowden, Richard A.

    2003-04-15

    The non-lead hollow point bullet of the instant invention comprises a mixed construction slug further comprising, a monolithic metal insert having a tapered (preferred conical) hollow point tip and a tapered (preferred conical) tail protrusion, and an unsintered powdered metal composite core in tandem alignment with the insert. The core has a hollow tapered (preferred conical) cavity tip portion coupled with the tapered (preferred conical) tail protrusion on the insert. An open tip jacket envelops at least a portion of the insert and the core. The jacket is swaged at the open tip.

  8. Twist-induced tuning in tapered fiber couplers.

    PubMed

    Birks, T A

    1989-10-01

    The power-splitting ratio of fused tapered single-mode fiber couplers can be reversibly tuned by axial twisting without affecting loss. The twist-tuning behavior of a range of different tapered couplers is described. A simple expression for twist-tuning can be derived by representing the effects of twist by a change in the refractive index profile. Good agreement between this expression and experimental results is demonstrated. Repeated tuning over tens of thousands of cycles is found not to degrade coupler performance, and a number of practical applications, including a freely tunable tapered coupler, are described.

  9. Racetrack resonator as a loss measurement platform for photonic components

    DOE PAGES

    Jones, Adam M.; Univ. of Arizona, Tucson, AZ; DeRose, Christopher T.; ...

    2015-10-27

    This work represents the first complete analysis of the use of a racetrack resonator to measure the insertion loss of efficient, compact photonic components. Beginning with an in-depth analysis of potential error sources and a discussion of the calibration procedure, the technique is used to estimate the insertion loss of waveguide width tapers of varying geometry with a resulting 95% confidence interval of 0.007 dB. Furthermore, the work concludes with a performance comparison of the analyzed tapers with results presented for four taper profiles and three taper lengths.

  10. Fretting-corrosion at the modular tapers interface: Inspection of standard ASTM F1875-98.

    PubMed

    Bingley, Rachel; Martin, Alan; Manfredi, Olivia; Nejadhamzeeigilani, Mahdiyar; Oladokun, Abimbola; Beadling, Andrew Robert; Siddiqui, Sohail; Anderson, James; Thompson, Jonathan; Neville, Anne; Bryant, Michael

    2018-05-01

    Interest in the degradation mechanisms at the modular tapers interfaces has been renewed due to increased reported cases of adverse reactions to metal debris and the appearance of wear and corrosion at the modular tapers interfaces at revision. Over the past two decades, a lot of research has been expended to understand the degradation mechanisms, with two primary implant loading procedures and orientations used consistently across the literature. ASTM F1875-98 is often used as a guide to understand and benchmark the tribocorrosion processes occurring within the modular tapers interface. This article presents a comparison of the two methods outlined in ASTM F1875-98 as well as a critique of the standard considering the current paradigm in pre-clinical assessment of modular tapers.

  11. Single and low order mode interrogation of a multimode sapphire fibre Bragg grating sensor with tapered fibres

    NASA Astrophysics Data System (ADS)

    Grobnic, D.; Mihailov, S. J.; Ding, H.; Bilodeau, F.; Smelser, C. W.

    2006-05-01

    Multimode sapphire fibre Bragg gratings (SFBG) made with an ultrafast Ti:sapphire 800 nm laser and a phase mask were probed using a tapered single mode fibre of different taper diameters to produce single and low order mode reflection/transmission responses. A configuration made of an input single mode tapered fibre and multimode silica fibre used for output coupling was also tested and has delivered a filtered multimode transmission spectrum. The tapered coupling improved the spectral resolution of the SFBG. Such improvements facilitate the utilization of the SFBG as a high temperature sensor. Wavelength shifts of the single mode response were monitored as a function of temperature up to 1500 °C with no detectable degradation in the grating strength or hysteresis in the Bragg resonance.

  12. Implementation of rectangular slit-inserted ultra-wideband tapered slot antenna.

    PubMed

    Kim, Sun-Woong; Choi, Dong-You

    2016-01-01

    In this paper, a tapered slot antenna capable of ultra-wideband communication was designed. In the proposed antenna, rectangular slits were inserted to enhance the bandwidth and reduce the area of the antenna. The rectangular slit-inserted tapered slot antenna operated at a bandwidth of 8.45 GHz, and the bandwidth improved upon the basic tapered slot antenna by 4.72 GHz. The radiation pattern of the antenna was suitable for location recognition in a certain direction owing to an appropriate 3 dB beam width. The antenna gain was analyzed within the proposed bandwidth, and the highest gain characteristic at 7.55 dBi was exhibited at a 5-GHz band. The simulation and measurement results of the proposed tapered slot antenna were similar.

  13. Tapered fiber Mach-Zehnder interferometers for vibration and elasticity sensing applications.

    PubMed

    Chen, Nan-Kuang; Hsieh, Yu-Hsin; Lee, Yi-Kun

    2013-05-06

    We demonstrate the optical measurements of heart-beat pulse rate and also elasticity of a polymeric tube, using a tapered fiber Mach-Zehnder interferometer. This device has two abrupt tapers in the Er/Yb codoped fiber and thus fractional amount of core mode is converted into cladding modes at the first abrupt taper. The core and cladding modes propagate through different optical paths and meet again at the second abrupt taper to produce interferences. The mechanical vibration signals generated by the blood vessels and by an inflated polymeric tube can perturb the optical paths of resonant modes to move around the resonant wavelengths. Thus, the cw laser signal is modulated to become pulses to reflect the heart-beat pulse rate and the elasticity of a polymeric tube, respectively.

  14. Plasmonic structure: fiber grating formed by gold nanorods on a tapered fiber.

    PubMed

    Trevisanutto, J O; Linhananta, A; Das, G

    2016-12-15

    The authors demonstrated the fabrication of a fiber Bragg grating-like plasmonic nanostructure on the surface of a tapered optical fiber using gold nanorods (GNRs). A multimode optical fiber with core and cladding diameters of 105 and 125 μm, respectively, was used to make a tapered fiber using a dynamic etching process. The tip diameter was ∼100  nm. Light from a laser was coupled to the untapered end of the fiber, which produced a strong evanescent field around the tapered section of the fiber. The gradient force due to the evanescent field trapped the GNRs on the surface of the tapered fiber. The authors explored possible causes of the GNR distribution. The plasmonic structure will be a good candidate for sensing based on surface enhanced Raman scattering.

  15. CROSS-DISCIPLINARY PHYSICS AND RELATED AREAS OF SCIENCE AND TECHNOLOGY: Novel Route to Fabrication of Metal-Sandwiched Nanoscale Tapered Structures

    NASA Astrophysics Data System (ADS)

    Zhang, Yang; Yu, Da-Peng

    2009-08-01

    Tapered dielectric structures in metal have exhibited extraordinary performance in both surface plasmon polariton (SPP) waveguiding and SPP focusing. This is crucial to plasmonic research and industrial plasmonic device integration. We present a method that facilitates easy fabrication of smooth-surfaced sub-micron tapered structures in large scale simply with electron beam lithography (EBL). When a PMMA layer is spin-coated on previously-EBL-defined PMMA structures, steep edges can be transformed into a declining slope to form tapered PMMA structures, scaled from 10 nm to 1000 nm. Despite the simplicity of our method, patterns with PMMA surface smoothness can be well-positioned and replicated in large numbers, which therefore gives scientists easy access to research on the properties of tapered structures.

  16. Micro-computed tomographic comparison of nickel-titanium rotary versus traditional instruments in C-shaped root canal system.

    PubMed

    Yin, Xingzhe; Cheung, Gary Shun-Pan; Zhang, Chengfei; Masuda, Yoshiko Murakami; Kimura, Yuichi; Matsumoto, Koukichi

    2010-04-01

    The purpose of this study was to assess the efficacy of instrumentation of C-shaped canals with ProTaper rotary system and traditional instruments by using micro-computed tomography (micro-CT). Twenty-four mandibular molars with C-shaped canals were selected in pairs and sorted equally into 2 groups, which were assigned for instrumentation by ProTaper rotary system (ProTaper group) or by K-files and Gates-Glidden burs (Hand Instrument group). Three-dimensional images were constructed by micro-CT. The volume of dentin removed, uninstrumented canal area, time taken for instrumentation, and iatrogenic error of instrumentation were investigated. Hand Instrument group showed greater amount of volumetric dentin removal and left less uninstrumented canal area than ProTaper group (P < .01). The time needed for instrumentation was shorter for ProTaper group than for Hand Instrument group (P < .05). No instrument breakage occurred in both groups, but more conspicuous procedural errors were detected in Hand Instrument group than for ProTaper group. It was concluded that ProTaper rotary system maintained the canal curvature with speediness and few procedural errors, whereas traditional instrumentation can clean more canal surface. Copyright (c) 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  17. Apical extrusion of debris in primary molar root canals using mechanical and manual systems.

    PubMed

    Buldur, B; Hascizmeci, C; Aksoy, S; Nur Aydin, M; Guvendi, O N

    2018-03-01

    Apical extrusion of debris in primary root canal treatment has not been well elucidated. The purpose of this study is to compare the amount of apically extruded debris during the preparation of primary molar root canals using ProTaper, ProTaper Next, Self-adjusting File (SAF) and hand files. One hundred sixty extracted primary mandibular molar teeth were assigned to 2 groups: Group 1: Resorbed (n=80) and Group 2: Non-resorbed (n=80) and randomly to four subgroups (n=20 teeth for each subgroup) according to the instruments used, ProTaper, ProTaper Next, SAF, and hand file. The apically extruded debris was collected and dried in preweighed Eppendof tubes. The dry weight was calculated by subtracting the preoperative weight from the postoperative weight. Data were analysed statistically using the ANOVA and the Bonferroni post hoc t-test. The amount of apically extruded debris was significantly less for the non-resorbed group compared to the resorbed group (P<0.05). Regardless of the resorption groups, ProTaper Next and SAF extruded significantly less debris than did the ProTaper and hand files (P<0.05), while no statistically significant difference was found between ProTaper Next and SAF (P>0.05). All instruments caused apically extruded debris in primary teeth.

  18. Guided-Mode-Leaky-Mode-Guided-Mode Fiber Interferometer and Its High Sensitivity Refractive Index Sensing Technology

    PubMed Central

    Wang, Qi; Li, Chunyue; Zhao, Chengwu; Li, Weizheng

    2016-01-01

    A cascaded symmetrical dual-taper Mach-Zehnder interferometer structure based on guided-mode and leaky-mode interference is proposed in this paper. Firstly, the interference spectrum characteristics of interferometer has been analyzed by the Finite Difference-Beam Propagation Method (FD-BPM). When the diameter of taper waist is 20 μm–30 μm, dual-taper length is 1 mm and taper distance is 4 cm–6 cm, the spectral contrast is higher, which is suitable for sensing. Secondly, experimental research on refractive index sensitivity is carried out. A refractive index sensitivity of 62.78 nm/RIU (refractive index unit) can achieved in the RI range of 1.3333–1.3792 (0%~25% NaCl solution), when the sensor structure parameters meet the following conditions: diameter of taper waist is 24 μm, dual-taper length is 837 μm and taper distance is 5.5 cm. The spectrum contrast is 0.8 and measurement resolution is 1.6 × 10−5 RIU. The simulation analysis is highly consistent with experimental results. Research shows that the sensor has promising application in low RI fields where high-precision measurement is required due to its high sensitivity and stability. PMID:27258281

  19. Opioid Tapering in Fibromyalgia Patients: Experience from an Interdisciplinary Pain Rehabilitation Program.

    PubMed

    Cunningham, Julie L; Evans, Michele M; King, Susan M; Gehin, Jessica M; Loukianova, Larissa L

    2016-09-01

    Despite current guideline recommendations against the use of opioids for the treatment of fibromyalgia pain, opioid use is reported in approximately 30% of the patient population. There is a lack of information describing the process and results of tapering of chronic opioids. The purpose of this study is to describe opioid tapering and withdrawal symptoms in fibromyalgia patients on opioids. This retrospective research study included a baseline analysis of 159 patients consecutively admitted to the Mayo Clinic Pain Rehabilitation Center from 2006 through 2012 with a pain diagnosis of fibromyalgia completing a 3-week outpatient interdisciplinary pain rehabilitation program. Opioid tapering analysis included 55 (35%) patients using daily opioids. Opioid tapering was individualized to each patient based on interdisciplinary pain rehabilitation team determination. Opioid withdrawal symptoms were assessed daily, utilizing the Clinical Opioid Withdrawal Scale. Patients taking daily opioids had a morphine equivalent mean dose of 99 mg/day. Patients on < 100 mg/day were tapered off over a mean of 10 days compared with patients on > 200 mg/day over a mean of 28 days (P < 0.001). Differences in peak withdrawal symptoms were not statistically significant based on the mean equivalent dose (P = 22). Patients taking opioids for <2 years did not differ in length of tapering (P =0.63) or peak COWS score (P =0.80) compared with >2 years duration. Patients had significant improvements in pain-related measures including numeric pain scores, depression catastrophizing, health perception, interference with life, and perceived life control at program completion. Fibromyalgia patients on higher doses of opioids were tapered off over a longer period of time but no differences in withdrawal symptoms were seen based on opioid dose. Duration of opioid use did not affect the time to complete opioid taper or withdrawal symptoms. Despite opioid tapering, pain-related measures improved at the completion of the rehabilitation program. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. Temperature sensing through long period fiber gratings mechanically induced on tapered optical fibers.

    PubMed

    Pulido-Navarro, María Guadalupe; Escamilla-Ambrosio, Ponciano Jorge; Marrujo-García, Sigifredo; Álvarez-Chávez, José Alfredo; Martínez-Piñón, Fernando

    2017-07-01

    In this work the feasibility of employing two well-known techniques already used on designing optical fiber sensors is explored. The first technique employed involves monomode tapered fibers, which were fabricated using a taper machine designed, built, and implemented in our laboratory. This implementation greatly reduced the costs and fabrication time allowing us to produce the desired taper length and transmission conditions. The second technique used fiber Bragg gratings, which we decided to have mechanically induced and for that reason we devised and produced our own mechanical gratings with the help of a computer numerical control tool. This grating had to be fabricated with aluminum to withstand temperatures of up to 600°C. When light traveling through an optical fiber reaches a taper it couples into the cladding layer and comes back into the core when the taper ends. In the same manner, when the light encounters gratings in the fiber, it couples to the cladding modes, and when the gratings end, the light couples back into the core. For our experimentation, the tapering machine was programmed to fabricate single-mode tapers with 3 cm length, and the mechanically induced gratings characteristics were 5 cm length, and had a period of 500 μm and depth of the period of 300 μm. For the conducting tests, the tapered fiber is positioned in between two aluminum slabs, one grooved and the other plane. These two blocks accomplish the mechanically induced long period grating (LPG); the gratings on the grooved plaque are imprinted on the taper forming the period gratings. An optical spectrum analyzer is used to observe the changes on the transmission spectrum as the temperature varies from 20°C to 600°C. The resultant attenuation peak wavelength in the transmission spectrum shifts up to 8 nm, which is a higher shift compared to what has been reported using nontapered fibers. As the temperature increases there is no longer a shift, but there is significant power loss. Such a characteristic can be used as well for sensing applications.

  1. The impact of hospital-wide use of a tapered-cuff endotracheal tube on the incidence of ventilator-associated pneumonia.

    PubMed

    Bowton, David L; Hite, R Duncan; Martin, R Shayn; Sherertz, Robert

    2013-10-01

    Aspiration of colonized oropharyngeal secretions is a major factor in the pathogenesis of ventilator-associated pneumonia (VAP). A tapered-cuff endotracheal tube (ETT) has been demonstrated to reduce aspiration around the cuff. Whether these properties are efficacious in reducing VAP is not known. This 2-period, investigator-initiated observational study was designed to assess the efficacy of a tapered-cuff ETT to reduce the VAP rate. All intubated, mechanically ventilated patients over the age of 18 were included. During the baseline period a standard, barrel-shaped-cuff ETT (Mallinckrodt Hi-Lo) was used. All ETTs throughout the hospital were then replaced with a tapered-cuff ETT (TaperGuard). The primary outcome variable was the incidence of VAP per 1,000 ventilator days. We included 2,849 subjects, encompassing 15,250 ventilator days. The mean ± SD monthly VAP rate was 3.29 ± 1.79/1,000 ventilator days in the standard-cuff group and 2.77 ± 2.00/1,000 ventilator days in the tapered-cuff group (P = .65). While adherence to the VAP prevention bundle was high throughout the study, bundle adherence was significantly higher during the standard-cuff period (96.5 ± 2.7%) than in the tapered-cuff period (90.3 ± 3.5%, P = .01). In the setting of a VAP rate very near the average of ICUs in the United States, and where there was high adherence to a VAP prevention bundle, the use of a tapered-cuff ETT was not associated with a reduction in the VAP rate.

  2. The effects of tapering on strength performance in trained athletes.

    PubMed

    Gibala, M J; MacDougall, J D; Sale, D G

    1994-11-01

    The optimum pre-competition taper procedure for "strength athletes" is not known. We examined voluntary strength and evoked contractile properties of the elbow flexors over a 10 day rest only (ROT) and a 10 day reduced volume taper (RVT) in 8 resistance trained males (23 +/- 2.1 years). Following 3 wks of standardized training of the elbow flexors, subjects were randomly assigned to one of the tapers. Upon completion, they resumed training for 3 wks and completed the other taper. No arm training was performed during the ROT, while high intensity, low volume training was done every second day during the RVT. Maximum isometric (MVC), low (0.52 rad.s-1; LV) and high velocity (3.14 rad.s-1; HV) concentric peak torque, and evoked isometric twitch contractile properties were measured before and after each training phase and every 48 h during each taper. ANOVA comparison of the tapers revealed that MVC increased (p < or = 0.05) over pre-taper values throughout the RVT (measurement days 2, 4, 6, 8 and 10), as did LV at 2, 4, 6, and 8 d. MVC did not change over the ROT but LV was significantly higher on day 2 and lower on days 8 and 10. LV was also greater on days 4, 6, 8 and 10 during the RVT compared to the ROT. The evoked contractile properties remained largely unchanged. The data indicate that resistance-trained athletes can improve low velocity concentric strength for at least 8 days by greatly reducing training volume, but maintaining training intensity.

  3. The Cervical Spinal Canal Tapers Differently in Patients with Chiari I with and without Syringomyelia.

    PubMed

    Thompson, A; Madan, N; Hesselink, J R; Weinstein, G; Munoz del Rio, A; Haughton, V

    2016-04-01

    The cause of syringomyelia in patients with Chiari I remains uncertain. Cervical spine anatomy modifies CSF velocities, flow patterns, and pressure gradients, which may affect the spinal cord. We tested the hypothesis that cervical spinal anatomy differs between Chiari I patients with and without syringomyelia. We identified consecutive patients with Chiari I at 3 institutions and divided them into groups with and without syringomyelia. Five readers measured anteroposterior cervical spinal diameters, tonsillar herniation, and syrinx dimensions on cervical MR images. Taper ratios for C1-C7, C1-C4, and C4-C7 spinal segments were calculated by linear least squares fitting to the appropriate spinal canal diameters. Mean taper ratios and tonsillar herniation for groups were compared and tested for statistical significance with a Kruskal-Wallis test. Inter- and intrareader agreement and correlations in the data were measured. One hundred fifty patients were included, of which 49 had syringomyelia. C1-C7 taper ratios were smaller and C4-C7 taper ratios greater for patients with syringomyelia than for those without it. C1-C4 taper ratios did not differ significantly between groups. Patients with syringomyelia had, on average, greater tonsillar herniation than those without a syrinx. However, C4-C7 taper ratios were steeper, for all degrees of tonsil herniation, in patients with syringomyelia. Differences among readers did not exceed differences among patient groups. The tapering of the lower cervical spine may contribute to the development of syringomyelia in patients with Chiari I. © 2016 by American Journal of Neuroradiology.

  4. Tapering Practices of Strongman Athletes: Test-Retest Reliability Study

    PubMed Central

    Pritchard, Hayden J; Keogh, Justin WL

    2017-01-01

    Background Little is currently known about the tapering practices of strongman athletes. We have developed an Internet-based comprehensive self-report questionnaire examining the training and tapering practices of strongman athletes. Objective The objective of this study was to document the test-retest reliability of questions associated with the Internet-based comprehensive self-report questionnaire on the tapering practices of strongman athletes. The information will provide insight on the reliability and usefulness of the online questionnaire for use with strongman athletes. Methods Invitations to complete an Internet questionnaire were sent via Facebook Messenger to identified strongman athletes. The survey consisted of four main areas of inquiry, including demographics and background information, training practices, tapering, and tapering practices. Of the 454 athletes that completed the survey over the 8-week period, 130 athletes responded on Facebook Messenger indicating that they intended to complete, or had completed, the survey. These participants were asked if they could complete the online questionnaire a second time for a test-retest reliability analysis. Sixty-four athletes (mean age 33.3 years, standard deviation [SD] 7.7; mean height 178.2 cm, SD 11.0; mean body mass 103.7 kg, SD 24.8) accepted this invitation and completed the survey for the second time after a minimum 7-day period from the date of their first completion. Agreement between athlete responses was measured using intraclass correlation coefficients (ICCs) and kappa statistics. Confidence intervals (at 95%) were reported for all measures and significance was set at P<.05. Results Test-retest reliability for demographic and training practices items were significant (P<.001) and showed excellent (ICC range=.84 to .98) and fair to almost perfect agreement (κ range=.37-.85). Moderate to excellent agreements (ICC range=.56-.84; P<.01) were observed for all tapering practice measures except for the number of days athletes started their usual taper before a strongman competition (ICC=.30). When the number of days were categorized with additional analyses, moderate reliability was observed (κ=.43; P<.001). Fair to substantial agreement was observed for the majority of tapering practices measures (κrange=.38-.73; P<.001) except for how training frequency (κ=.26) and the percentage and type of resistance training performed, which changed in the taper (κ=.20). Good to excellent agreement (ICC=.62-.93; P<.05) was observed for items relating to strongman events and traditional exercises performed during the taper. Only the time at which the Farmer’s Walk was last performed before competition showed poor reliability (ICC=.27). Conclusions We have developed a low cost, self-reported, online retrospective questionnaire, which provided stable and reliable answers for most of the demographic, training, and tapering practice questions. The results of this study support the inferences drawn from the Tapering Practices of Strongman Athletes Study. PMID:29089292

  5. 76 FR 72213 - Tapered Roller Bearings From China; Notice of Commission determination To Conduct a Full Five...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-22

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-344 (Third Review)] Tapered Roller Bearings From China; Notice of Commission determination To Conduct a Full Five-Year Review AGENCY: United...(c)(5)) to determine whether revocation of the antidumping duty order on tapered roller bearings from...

  6. 78 FR 45912 - Tapered Roller Bearings and Parts Thereof, Finished and Unfinished, From the People's Republic of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-30

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-601] Tapered Roller Bearings and... Bearing Co., Ltd.'s (Tainai's) request for a new shipper review (NSR) of the antidumping duty order on tapered roller bearings and parts thereof, finished and unfinished (TRBs), from the People's Republic of...

  7. A Volume and Taper Prediction System for Bald Cypress

    Treesearch

    Bernard R. Parresol; James E. Hotvedt; Quang V. Cao

    1987-01-01

    A volume and taper prediction system based on d10 and consisting of a total volume equation, two volume ratio equations (one for diameter limits, the other for height limits), and a taper equation was developed for bald cypress using sample tree data collected in Louisiana. Normal diameter (dn), a subjective variable-...

  8. Efficacy of Twisted File Adaptive, Reciproc and ProTaper Universal Retreatment instruments for root-canal-filling removal: A cone-beam computed tomography study.

    PubMed

    Akbulut, Makbule Bilge; Akman, Melek; Terlemez, Arslan; Magat, Guldane; Sener, Sevgi; Shetty, Heeresh

    2016-01-01

    The aim of this study was to evaluate the efficacy of Twisted File (TF) Adaptive, Reciproc, and ProTaper Universal Retreatment (UR) System instruments for removing root-canal-filling. Sixty single rooted teeth were decoronated, instrumented and obturated. Preoperative CBCT scans were taken and the teeth were retreated with TF Adaptive, Reciproc, ProTaper UR, or hand files (n=15). Then, the teeth were rescanned, and the percentage volume of the residual root-canal-filling material was established. The total time for retreatment was recorded, and the data was statistically analyzed. The statistical ranking of the residual filling material volume was as follows: hand file=TF Adaptive>ProTaper UR=Reciproc. The ProTaper UR and Reciproc systems required shorter periods of time for retreatment. Root canal filling was more efficiently removed by using Reciproc and ProTaper UR instruments than TF Adaptive instruments and hand files. The TF Adaptive system was advantageous over hand files with regard to operating time.

  9. Radiological evaluation of the morphological changes of root canals shaped with ProTaper for hand use and the ProTaper and RaCe rotary instruments.

    PubMed

    Aguiar, Carlos M; Câmara, Andréa C

    2008-12-01

    This study evaluated, by means of the radiography examination, the occurrence of deviations in the apical third of root canals shaped with hand and rotary instruments. Sixty mandibular human molars were divided into three groups. The root canals in group 1 were instrumented with ProTaper (Dentsply/Maillefer, Ballaigues, Switzerland) for hand use, group 2 with ProTaper and group 3 with RaCe. The images obtained by double superimposition of the pre- and postoperative radiographs were evaluated by two endodontists with the aid of a magnifier-viewer and a fivefold magnifier. Statistical analysis was performed using the Fisher-Freeman-Halton. The instrumentation using the ProTaper for hand use showed 25% of the canals with a deviation in the apical third, as did the ProTaper, while the corresponding figure for the RaCe (FKG Dentaire, La-Chaux-de-Fonds, Switzerland) was 20%, but these results were not statistically significant. There was no correlation between the occurrence of deviations in the apical third and the systems used.

  10. Micro-CT evaluation of the effectiveness of the combined use of rotary and hand instrumentation in removal of Resilon.

    PubMed

    Asheibi, Fatma; Qualtrough, Alison J E; Mellor, Anthony; Withers, Philip J; Lowe, Tristan

    2014-01-01

    This study compares the effectiveness of ProTaper rotary files with ProTaper retreatment and K-files in the removal of Resilon or gutta percha (GP) from canals filled either by cold lateral condensation or thermal obturation using micro-CT. Ninety-six teeth were prepared using ProTaper files and allocated into four groups (n=24): Group-1 was filled with GP/AH-Plus and Group-2 with Resilon/RealSeal using cold lateral condensation. Group-3 was filled with GP/AH-Plus and Group-4 with Resilon/RealSeal using System B and Obtura II. The roots were scanned by micro-CT. Each group was divided into two subgroups (n=12): A, retreated using ProTaper files and B, using ProTaper retreatment and K-files. The roots were scanned to calculate the volume of the remaining material. With thermal obturation, roots filled with Resilon had significantly more remaining material than GP. Obturation using thermal technique resulted in significantly less remaining material than cold condensation except Resilon retreated using ProTaper retreatment and K-files.

  11. Flexural-torsional vibration of a tapered C-section beam

    NASA Astrophysics Data System (ADS)

    Dennis, Scott T.; Jones, Keith W.

    2017-04-01

    Previous studies have shown that numerical models of tapered thin-walled C-section beams based on a stepped or piecewise prismatic beam approximation are inaccurate regardless of the number of elements assumed in the discretization. Andrade recently addressed this problem by extending Vlasov beam theory to a tapered geometry resulting in new terms that vanish for the uniform beam. (See One-Dimensional Models for the Spatial Behaviour of Tapered Thin-Walled Bars with Open Cross-Sections: Static, Dynamic and Buckling Analyses, PhD Thesis, University of Coimbra, Portugal, 2012, https://estudogeral.sib.uc.pt) In this paper, we model the coupled bending-twisting vibration of a cantilevered tapered thin-walled C-section using a Galerkin approximation of Andrade's beam equations resulting in an 8-degree-of-freedom beam element. Experimental natural frequencies and mode shapes for 3 prismatic and 2 tapered channel beams are compared to model predictions. In addition, comparisons are made to detailed shell finite element models and exact solutions for the uniform beams to confirm the validity of the approach. Comparisons to the incorrect stepped model are also presented.

  12. Multitaper spectral analysis of atmospheric radar signals

    NASA Astrophysics Data System (ADS)

    Anandan, V.; Pan, C.; Rajalakshmi, T.; Ramachandra Reddy, G.

    2004-11-01

    Multitaper spectral analysis using sinusoidal taper has been carried out on the backscattered signals received from the troposphere and lower stratosphere by the Gadanki Mesosphere-Stratosphere-Troposphere (MST) radar under various conditions of the signal-to-noise ratio. Comparison of study is made with sinusoidal taper of the order of three and single tapers of Hanning and rectangular tapers, to understand the relative merits of processing under the scheme. Power spectra plots show that echoes are better identified in the case of multitaper estimation, especially in the region of a weak signal-to-noise ratio. Further analysis is carried out to obtain three lower order moments from three estimation techniques. The results show that multitaper analysis gives a better signal-to-noise ratio or higher detectability. The spectral analysis through multitaper and single tapers is subjected to study of consistency in measurements. Results show that the multitaper estimate is better consistent in Doppler measurements compared to single taper estimates. Doppler width measurements with different approaches were studied and the results show that the estimation was better in the multitaper technique in terms of temporal resolution and estimation accuracy.

  13. Sideband instability analysis based on a one-dimensional high-gain free electron laser model

    DOE PAGES

    Tsai, Cheng-Ying; Wu, Juhao; Yang, Chuan; ...

    2017-12-18

    When an untapered high-gain free electron laser (FEL) reaches saturation, the exponential growth ceases and the radiation power starts to oscillate about an equilibrium. The FEL radiation power or efficiency can be increased by undulator tapering. For a high-gain tapered FEL, although the power is enhanced after the first saturation, it is known that there is a so-called second saturation where the FEL power growth stops even with a tapered undulator system. The sideband instability is one of the primary reasons leading to this second saturation. In this paper, we provide a quantitative analysis on how the gradient of undulatormore » tapering can mitigate the sideband growth. The study is carried out semianalytically and compared with one-dimensional numerical simulations. The physical parameters are taken from Linac Coherent Light Source-like electron bunch and undulator systems. The sideband field gain and the evolution of the radiation spectra for different gradients of undulator tapering are examined. It is found that a strong undulator tapering (~10 % ) provides effective suppression of the sideband instability in the postsaturation regime.« less

  14. Sideband instability analysis based on a one-dimensional high-gain free electron laser model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, Cheng-Ying; Wu, Juhao; Yang, Chuan

    When an untapered high-gain free electron laser (FEL) reaches saturation, the exponential growth ceases and the radiation power starts to oscillate about an equilibrium. The FEL radiation power or efficiency can be increased by undulator tapering. For a high-gain tapered FEL, although the power is enhanced after the first saturation, it is known that there is a so-called second saturation where the FEL power growth stops even with a tapered undulator system. The sideband instability is one of the primary reasons leading to this second saturation. In this paper, we provide a quantitative analysis on how the gradient of undulatormore » tapering can mitigate the sideband growth. The study is carried out semianalytically and compared with one-dimensional numerical simulations. The physical parameters are taken from Linac Coherent Light Source-like electron bunch and undulator systems. The sideband field gain and the evolution of the radiation spectra for different gradients of undulator tapering are examined. It is found that a strong undulator tapering (~10 % ) provides effective suppression of the sideband instability in the postsaturation regime.« less

  15. The shaping effects of three nickel-titanium rotary instruments in simulated S-shaped canals.

    PubMed

    Yoshimine, Y; Ono, M; Akamine, A

    2005-05-01

    The purpose of this study was to compare the shaping effects of three nickel-titanium rotary instruments, ProTaper, K3, and RaCe, with emphasis on canal transportation. Simulated canals with an S-shaped curvature in clear resin blocks were prepared with a torque-control, low-speed engine. Canals were prepared using the crown-down technique to the size of #30. Canal aberrations were assessed by comparing the pre- and postinstrumentation images under a stereomicroscope. ProTaper instruments caused greater widening of canals compared to K3 or RaCe. Furthermore, ProTaper files showed a tendency to ledge or zip formation at the end-point of preparation. These canal aberrations may be caused by ProTaper finishing files, which appear to be less flexible than other files of the same tip-size, because of their greater taper-size. These results suggest that nickel-titanium file systems including less tapered, more flexible instruments, like K3 and RaCe should be used in the apical preparation of canals with a complicated curvature.

  16. Sideband instability analysis based on a one-dimensional high-gain free electron laser model

    NASA Astrophysics Data System (ADS)

    Tsai, Cheng-Ying; Wu, Juhao; Yang, Chuan; Yoon, Moohyun; Zhou, Guanqun

    2017-12-01

    When an untapered high-gain free electron laser (FEL) reaches saturation, the exponential growth ceases and the radiation power starts to oscillate about an equilibrium. The FEL radiation power or efficiency can be increased by undulator tapering. For a high-gain tapered FEL, although the power is enhanced after the first saturation, it is known that there is a so-called second saturation where the FEL power growth stops even with a tapered undulator system. The sideband instability is one of the primary reasons leading to this second saturation. In this paper, we provide a quantitative analysis on how the gradient of undulator tapering can mitigate the sideband growth. The study is carried out semianalytically and compared with one-dimensional numerical simulations. The physical parameters are taken from Linac Coherent Light Source-like electron bunch and undulator systems. The sideband field gain and the evolution of the radiation spectra for different gradients of undulator tapering are examined. It is found that a strong undulator tapering (˜10 %) provides effective suppression of the sideband instability in the postsaturation regime.

  17. Corrosion on the acetabular liner taper from retrieved modular metal-on-metal total hip replacements.

    PubMed

    Gascoyne, Trevor C; Dyrkacz, Richard M; Turgeon, Thomas R; Burnell, Colin D; Wyss, Urs P; Brandt, Jan-M

    2014-10-01

    Eight retrieved metal-on-metal total hip replacements displayed corrosion damage along the cobalt-chromium alloy liner taper junction with the Ti alloy acetabular shell. Scanning electron microscopy indicated the primary mechanism of corrosion to be grain boundary and associated crevice corrosion, which was likely accelerated through mechanical micromotion and galvanic corrosion resulting from dissimilar alloys. Coordinate measurements revealed up to 4.3mm(3) of the cobalt-chromium alloy taper surface was removed due to corrosion, which is comparable to previous reports of corrosion damage on head-neck tapers. The acetabular liner-shell taper appears to be an additional source of metal corrosion products in modular total hip replacements. Patients with these prostheses should be closely monitored for signs of adverse reaction towards corrosion by-products. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Single and low order mode interrogation of a multimode sapphire fiber Bragg grating sensor with tapered fibers

    NASA Astrophysics Data System (ADS)

    Grobnic, Dan; Mihailov, Stephen J.; Ding, H.; Bilodeau, F.; Smelser, Christopher W.

    2005-05-01

    Multimode sapphire fiber Bragg gratings (SFBG) made with an IR femtosecond laser and a phase mask were probed using tapered single mode fibers of different taper diameters producing single and low order mode reflection/transmission responses. A configuration made of an input single mode tapered fiber and multimode silica fiber used for output coupling was also tested and has delivered a filtered multimode transmission spectrum. The tapered coupling improved the spectral resolution of the SFBG as compared to its multimode responses previously reported. Such improvements facilitate the utilization of the SFBG as a high temperature sensor. Wavelength shifts of the single mode response were monitored as a function of temperature up to 1500 °C and were consistent with the measurement obtained from the multimode response published previously.

  19. Vertically-tapered optical waveguide and optical spot transformer formed therefrom

    DOEpatents

    Bakke, Thor; Sullivan, Charles T.

    2004-07-27

    An optical waveguide is disclosed in which a section of the waveguide core is vertically tapered during formation by spin coating by controlling the width of an underlying mesa structure. The optical waveguide can be formed from spin-coatable materials such as polymers, sol-gels and spin-on glasses. The vertically-tapered waveguide section can be used to provide a vertical expansion of an optical mode of light within the optical waveguide. A laterally-tapered section can be added adjacent to the vertically-tapered section to provide for a lateral expansion of the optical mode, thereby forming an optical spot-size transformer for efficient coupling of light between the optical waveguide and a single-mode optical fiber. Such a spot-size transformer can also be added to a III-V semiconductor device by post processing.

  20. High pressure, high current, low inductance, high reliability sealed terminals

    DOEpatents

    Hsu, John S [Oak Ridge, TN; McKeever, John W [Oak Ridge, TN

    2010-03-23

    The invention is a terminal assembly having a casing with at least one delivery tapered-cone conductor and at least one return tapered-cone conductor routed there-through. The delivery and return tapered-cone conductors are electrically isolated from each other and positioned in the annuluses of ordered concentric cones at an off-normal angle. The tapered cone conductor service can be AC phase conductors and DC link conductors. The center core has at least one service conduit of gate signal leads, diagnostic signal wires, and refrigerant tubing routed there-through. A seal material is in direct contact with the casing inner surface, the tapered-cone conductors, and the service conduits thereby hermetically filling the interstitial space in the casing interior core and center core. The assembly provides simultaneous high-current, high-pressure, low-inductance, and high-reliability service.

  1. Tapered waveguides for guided wave optics.

    PubMed

    Campbell, J C

    1979-03-15

    Strip waveguides having half-paraboloid shaped tapers that permit efficient fiber to waveguide coupling have been fabricated by Ag ion exchange in soda-lime glass. A reduction in the input coupling loss has been accomplished by tailoring the diffusion to provide a gradual transition from a single-mode waveguide to a multimode waveguide having cross-sectional dimensions comparable to the core diameter of a single-mode fiber. Waveguides without tapers exhibit an attenuation of 1.0 dB/cm and an input coupling loss of 0.6 dB. The additional loss introduced by the tapered region is 0.5 dB. By way of contrast, an input coupling loss of 2.4 dB is obtained by coupling directly to a single-mode waveguide, indicating a net improvement of 1.3 dB for the tapered waveguides.

  2. High-sensitivity refractive index sensors based on fused tapered photonic crystal fiber

    NASA Astrophysics Data System (ADS)

    Fu, Xing-hu; Xie, Hai-yang; Yang, Chuan-qing; Qu, Yu-wei; Zhang, Shun-yang; Fu, Guang-wei; Guo, Xuan; Bi, Wei-hong

    2016-05-01

    In this paper, a novel liquid refractive index (RI) sensor based on fused tapered photonic crystal fiber (PCF) is proposed. It is fabricated by fusing and tapering a section of PCF which is spliced with two single-mode fibers (SMFs). Due to the fused biconical taper method, the sensor becomes longer and thinner, to make the change of the outside RI has more direct effects on the internal optical field of the PCF, which finally enhances the sensitivity of this sensor. Experimental results show that the transmission spectra of the sensor are red-shifted obviously with the increase of RI. The longer the tapered region of the sensor, the higher the sensitivity is. This sensor has the advantages of simple structure, easy fabrication, high performance and so on, so it has potential applications in RI measurement.

  3. Determination of doxorubicin in plasma by using CE coupled with in-column tapered optic-fiber light-emitting diode induced fluorescence detection.

    PubMed

    Yang, Xiupei; Qian, Fan; Xie, Linxiang; Yang, Xiaocui; Cheng, Xiumei; Choi, Martin M F

    2014-03-01

    This paper proposes a novel strategy to enhance detection of doxorubicin in human plasma, using homemade CE combined with normal stacking mode (NSM). The detection system of CE named as in-column tapered optic-fiber light-emitting diode induced fluorescence detection system is economic and more sensitive that has been demonstrated in our previous work. The influence of sample matrix, BGE, applied voltage, and injection time on the efficiency of NSM were systematically investigated. The clean extracts were subjected to CE separation with optimal experimental conditions: Ethanol-water (1:1, v/v) was used as sample matrix, pH 4.12 15 mM sodium phosphate buffer solution containing 70% v/v ACN, applied voltage 23 kV and 45 s hydrodynamic injection at a height of 20 cm. The detection system displayed linear dynamic range from 6.4 to 1.13 × 10(3) ng/mL with a correlation coefficient of 0.9990 and LOD 2.2 ng/mL for doxorubicin (DOX). The proposed CE method has been successfully applied to determine DOX in human plasma which the recoveries of standard DOX added to human plasma were found to been the range of 93.8-104.6%. The results obtained demonstrate that our detection system combined with NSM is a good idea to enhance sensitivity in CE for routine determination of DOX in some biological specimens. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Free-Flow Open-Chamber Electrophoresis

    NASA Technical Reports Server (NTRS)

    Sharnez, Rizwan; Sammons, David W.

    1994-01-01

    Free-flow open-chamber electrophoresis variant of free-flow electrophoresis performed in chamber with open ends and in which velocity of electro-osmotic flow adjusted equal to and opposite mean electrophoretic velocity of sample. Particles having electrophoretic mobilities greater than mean mobility of sample particles move toward cathode, those with mobilities less move toward anode. Technique applied to separation of components of mixtures of biologically important substances. Sensitivity enhanced by use of tapered chamber.

  5. Experiments on tandem diffusers with boundary-layer suction applied in between

    NASA Technical Reports Server (NTRS)

    Barna, P. S.

    1979-01-01

    Experiments were performed on conical diffusers of various configurations with the same, but rather unusually large, 16:1 area ratio. Because available performance data on diffusers fall short of very large area ratio configurations, an unconventional design, consisting of two diffusers following each other in tandem, was proposed. Both diffusers had the same area ratio of 4:1, but had different taper angles. While for the first diffuser (called leading) the angle remained constant, for the second (called follower), the taper angle was stepped up to higher values. Boundary layer control, by way of suction, was applied between the diffusers, and a single slot suction ring was inserted between them. The leading diffuser had an enclosed nominal divergence angle 2 theta = 5 degrees, while the follower diffusers had either 10, 20, 30, or 40 degrees, respectively, giving 4 combinations. The experiments were performed at four different Reynolds numbers with various suction rates. The rates indicate a general improvement in the performance of all diffusers with boundary layer suction. It appears that the improvement of the pressure recovery depends on both the Reynolds number and the suction rate, and the largest increase, 0.075, was found at the lowest R sub e when the follower divergence was 2 theta = 40 degrees.

  6. 65-fs Yb-doped all-fiber laser using tapered fiber for nonlinearity and dispersion management.

    PubMed

    Yang, Peilong; Teng, Hao; Fang, Shaobo; Hu, Zhongqi; Chang, Guoqing; Wang, Junli; Wei, Zhiyi

    2018-04-15

    We implement an ultrafast Yb-doped all-fiber laser which incorporates tapered single-mode fibers for managing nonlinearity and dispersion. The tapered fiber placed in the oscillator cavity aims to broaden the optical spectrum of the intracavity pulse. At the oscillator output, we use another tapered fiber to perform pulse compression. The resulting 66.1-MHz Yb-doped all-fiber oscillator self-starts and generates 0.4-nJ, 65-fs pulses, which can serve as a compact and robust seed source for subsequent high-power, high-energy amplifiers.

  7. Fusion splice between tapered inhibited coupling hypocycloid-core Kagome fiber and SMF.

    PubMed

    Zheng, Ximeng; Debord, Benoît; Vincetti, Luca; Beaudou, Benoît; Gérôme, Frédéric; Benabid, Fetah

    2016-06-27

    We report for the first time on tapering inhibited coupling (IC) hypocycloid-core shape Kagome hollow-core photonic crystal fibers whilst maintaining their delicate core-contour negative curvature with a down-ratio as large as 2.4. The transmission loss of down-tapered sections reaches a figure as low as 0.07 dB at 1550 nm. The tapered IC fibers are also spliced to standard SMF with a total insertion loss of 0.48 dB. These results show that all-fiber photonic microcells with the ultra-low loss hypocycloid core-contour Kagome fibers is now possible.

  8. Adiabatically tapered splice for selective excitation of the fundamental mode in a multimode fiber.

    PubMed

    Jung, Yongmin; Jeong, Yoonchan; Brambilla, Gilberto; Richardson, David J

    2009-08-01

    We propose a simple and effective method to selectively excite the fundamental mode of a multimode fiber by adiabatically tapering a fusion splice to a single-mode fiber. We experimentally demonstrate the method by adiabatically tapering splice (taper waist=15 microm, uniform length=40 mm) between single-mode and multimode fiber and show that it provides a successful mode conversion/connection and allows for almost perfect fundamental mode excitation in the multimode fiber. Excellent beam quality (M(2) approximately 1.08) was achieved with low loss and high environmental stability.

  9. Highly Sensitive Refractive Index Sensor Based on Adiabatically Tapered Microfiber Long Period Gratings

    PubMed Central

    Ji, Wen Bin; Tjin, Swee Chuan; Lin, Bo; Ng, Choong Leng

    2013-01-01

    We demonstrate a refractive index sensor based on a long period grating (LPG) inscribed in a special photosensitive microfiber with double-clad profile. The fiber is tapered gradually enough to ensure the adiabaticity of the fiber taper. In other words, the resulting insertion loss is sufficiently small. The boron and germanium co-doped inner cladding makes it suitable for inscribing gratings into its tapered form. The manner of wavelength shift for refractive indices (RIs) differs from conventional LPG, and the refractive index detection limit is 1.67 × 10−5. PMID:24141267

  10. Highly sensitive refractive index sensor based on adiabatically tapered microfiber long period gratings.

    PubMed

    Ji, Wen Bin; Tjin, Swee Chuan; Lin, Bo; Ng, Choong Leng

    2013-10-17

    We demonstrate a refractive index sensor based on a long period grating (LPG) inscribed in a special photosensitive microfiber with double-clad profile. The fiber is tapered gradually enough to ensure the adiabaticity of the fiber taper. In other words, the resulting insertion loss is sufficiently small. The boron and germanium co-doped inner cladding makes it suitable for inscribing gratings into its tapered form. The manner of wavelength shift for refractive indices (RIs) differs from conventional LPG, and the refractive index detection limit is 1.67 × 10⁻⁵.

  11. Synthesis of Tapered CdS Nanobelts and CdSe Nanowires with Good Optical Property by Hydrogen-Assisted Thermal Evaporation

    PubMed Central

    2009-01-01

    The tapered CdS nanobelts and CdSe nanowires were prepared by hydrogen-assisted thermal evaporation method. Different supersaturation leads to two different kinds of 1D nanostructures. The PL measurements recorded from the as-prepared tapered CdS nanobelts and CdSe nanowires show only a bandgap emission with relatively narrow full-width half maximum, which means that they possess good optical property. The as-synthesized high-quality tapered CdS nanobelts and CdSe nanowires may be excellent building blocks for photonic devices. PMID:20596418

  12. Experimental results for characterization of a tapered plastic optical fiber sensor based on SPR

    NASA Astrophysics Data System (ADS)

    Cennamo, N.; Galatus, R.; Zeni, L.

    2015-05-01

    The experimental results obtained with two different Plastic Optical Fiber (POF) geometries, tapered and not-tapered, for a sensor based on Surface Plasmon Resonance (SPR) are presented. SPR is used for determining the refractive index variations at the interface between a gold layer and a dielectric medium (aqueous medium). In this work SPR sensors in POF configurations, useful for bio-sensing applications, have been realized for the optimization of the sensitivity and experimentally tested. The results show as the sensitivity increases with the tapered POF configuration, when the refractive index of aqueous medium increases.

  13. Adult Mammalian Neural Stem Cells and Neurogenesis: Five Decades Later

    PubMed Central

    Bond, Allison M.; Ming, Guo-li; Song, Hongjun

    2015-01-01

    Summary Adult somatic stem cells in various organs maintain homeostatic tissue regeneration and enhance plasticity. Since its initial discovery five decades ago, investigations of adult neurogenesis and neural stem cells have led to an established and expanding field that has significantly influenced many facets of neuroscience, developmental biology and regenerative medicine. Here we review recent progress and focus on questions related to adult mammalian neural stem cells that also apply to other somatic stem cells. We further discuss emerging topics that are guiding the field toward better understanding adult neural stem cells and ultimately applying these principles to improve human health. PMID:26431181

  14. The Frank Stinchfield Award: the impact of socioeconomic factors on outcome after THA: a prospective, randomized study.

    PubMed

    Allen Butler, R; Rosenzweig, Seth; Myers, Leann; Barrack, Robert L

    2011-02-01

    Most studies of total hip arthroplasty (THA) focus on the effect of the type of implant on the clinical result. Relatively little data are available on the impact of the patient's preoperative status and socioeconomic factors on the clinical results following THA. We determined the relative importance of patient preoperative and socioeconomic status compared to implant and technique factors in predicting patient outcome as reflected by scores on commonly utilized rating scales (eg, Harris Hip Score, WOMAC, SF-12, degree of patient satisfaction, or presence or severity of thigh pain) following cementless THA. All patients during the study period were offered enrollment in a prospective, randomized study to receive either a titanium, tapered, proximally coated stem; or a Co-Cr, cylindrical, extensively coated stem; 102 patients were enrolled. We collected detailed patient data preoperatively including diagnosis, age, gender, insurance status, medical comorbidities, tobacco and alcohol use, household income, educational level, and history of treatment for lumbar spine pathology. Clinical evaluation included Harris Hip Score, SF-12, WOMAC, pain drawing, and UCLA activity rating and satisfaction questionnaire. Implant factors included stem type, stem size, fit in the canal, and stem-bone stiffness ratios. Minimum 2 year followup was obtained in 95% of the enrolled patients (102 patients). Patient demographics and preoperative status were more important than implant factors in predicting the presence of thigh pain, dissatisfaction, and a low hip score. The most predictive factors were ethnicity, educational level, poverty level, income, and a low preoperative WOMAC score or preoperative SF-12 mental component score. No implant parameter correlated with outcome or satisfaction. Socioeconomic factors and preoperative status have more impact on the clinical outcome of cementless THA than implant related factors. Level I, prospective, randomized clinical trial. See the guidelines online for a complete description of level of evidence.

  15. Applied STEM Coursework, High School Dropout Rates, and Students with Learning Disabilities

    ERIC Educational Resources Information Center

    Plasman, Jay Stratte; Gottfried, Michael A.

    2018-01-01

    Applied science, technology, engineering, and math (STEM) coursetaking is becoming more commonplace in traditional high school settings to help students reinforce their learning in academic STEM courses. Throughout U.S. educational history, vocational education has been a consistent focus for schools to keep students on the school-to-career…

  16. Comparative study of ProTaper gold, reciproc, and ProTaper universal for root canal preparation in severely curved root canals

    PubMed Central

    Arslan, Hakan; Yildiz, Ezgi Doganay; Gunduz, Hicran Ates; Sumbullu, Meltem; Bayrakdar, Ibrahim Sevki; Karatas, Ertugrul; Sumbullu, Muhammed Akif

    2017-01-01

    Aim: The aim of this study is to evaluate the root canal transportation, centering ability, and instrumentation times with the ProTaper Gold (Dentsply Tulsa Dental, Tulsa, OK, USA), Reciproc (VDW, Munich, Germany), and ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland) using cone-beam computed tomography (CBCT). Materials and Methods: Thirty mesial root canals of mandibular first molars with curvature angles of 35°–70° and radii of 2–6 mm were included in the study. Root canal instrumentation was performed up to F2 or R25. The instrumentation times were recorded. CBCT scanning was performed both pre- and post-instrumentation. Root canal transportation and the centering ratio were calculated for groups, and the data were analyzed using a one-way ANOVA and least significant difference post hoc tests for the instrumentation time, root canal transportation, and centering ratio at the 95% confidence level (P = 0.05). Results: At 3, 5, and 7 mm levels, there was no significant difference in the root canal transportation and centering ratio among the groups (P > 0.05). There were significant differences between the Reciproc and ProTaper Universal groups in the instrumentation times (P < 0.05). Conclusion: Root canal transportation and the centering ratio with the ProTaper Gold were similar to those obtained with the ProTaper Universal and Reciproc. PMID:29259355

  17. Effects of self-adjusting file, Mtwo, and ProTaper on the root canal wall.

    PubMed

    Hin, Ellemieke S; Wu, Min-Kai; Wesselink, Paul R; Shemesh, Hagay

    2013-02-01

    The purpose of this ex vivo study was to observe the incidence of cracks in root dentin after root canal preparation with hand files, self-adjusting file (SAF), ProTaper, and Mtwo. One hundred extracted mandibular premolars with single canals were randomly selected. Two angulated radiographs were taken for each tooth, and the width of the canal was measured at 9 mm from the apex. Five groups of 20 teeth each were comparable in canal width. The control group was left unprepared. Four experimental groups were instrumented with hand files, ProTaper, Mtwo, and SAF. Roots were then sectioned horizontally and observed under a microscope. The presence of dentinal cracks and their location were noted. The difference between the experimental groups was analyzed with a χ(2) test. No cracks were observed in the control group. In the experimental groups, ProTaper, Mtwo, and SAF caused cracks in 35%, 25%, and 10% of teeth, respectively. The hand-file group did not show any dentinal cracks (P < .0001). ProTaper and Mtwo caused more cracks than hand files (P < .05), but SAF did not (P > .05). Instrumentation of root canals with SAF, Mtwo, and ProTaper could cause damage to root canal dentin. SAF has a tendency to cause less dentinal cracks as compared with ProTaper or Mtwo. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  18. Assessment of apically extruded debris produced by the single-file ProTaper F2 technique under reciprocating movement.

    PubMed

    De-Deus, Gustavo; Brandão, Maria Claudia; Barino, Bianca; Di Giorgi, Karina; Fidel, Rivail Antonio Sergio; Luna, Aderval Severino

    2010-09-01

    This study was designed to quantitatively evaluate the amount of dentin debris extruded from the apical foramen by comparing the conventional sequence of the ProTaper Universal nickel-titanium (NiTi) files with the single-file ProTaper F2 technique. Thirty mesial roots of lower molars were selected, and the use of different instrumentation techniques resulted in 3 groups (n=10 each). In G1, a crown-down hand-file technique was used, and in G2 conventional ProTaper Universal technique was used. In G3, ProTaper F2 file was used in a reciprocating motion. The apical finish preparation was equivalent to ISO size 25. An apparatus was used to evaluate the apically extruded debris. Statistical analysis was performed using 1-way analysis of variance and Tukey multiple comparisons. No significant difference was found in the amount of the debris extruded between the conventional sequence of the ProTaper Universal NiTi files and the single-file ProTaper F2 technique (P>.05). In contrast, the hand instrumentation group extruded significantly more debris than both NiTi groups (P<.05). The present results yielded favorable input for the F2 single-file technique in terms of apically extruded debris, inasmuch as it is the most simple and cost-effective instrumentation approach. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  19. [Evaluation of preparation of curved root canals using hand-used ProTaper].

    PubMed

    Nie, Min; Zhao, Xin-Chen; Peng, Bin; Fan, Ming-Wen; Bian, Zhuan

    2009-05-01

    To evaluate the shaping ability of hand-used ProTaper on curved canals using Endodontic Cube. Fifty-four curved root canals in vitro were selected and divided into three groups according to the curved degree (alpha), group A: 0 degrees < or = alpha < 25 degrees , group B: 25 degrees < or = alpha < 40 degrees , group C: 40 degrees < or = alpha < 55 degrees . Endodontic Cube was assembled, and each sample was sectioned perpendicular to the axis of the tooth into four sections with Isomer-Buhler in low speed. Then the root canals were prepared with hand-used ProTaper. Before and after shaping, photograph of all the sections were taken under a stereomicroscope. Statistical analyses were performed. The dentin cutting quantity of the whole canal prepared with ProTaper in group B and C was larger than that of group A. The deviation distance of the whole canal prepared by ProTaper in group C was significantly larger than that in group A, and the deviation distance in middle portion larger than that in group B. The maintaining ability in the middle portion of group C by ProTaper was worse than that of group A and B. The curvature of root canal may increase the cutting quantity of the -dentin and reduce the ability of remaining original canal shape prepared by ProTaper.

  20. Morse taper dental implants and platform switching: The new paradigm in oral implantology

    PubMed Central

    Macedo, José Paulo; Pereira, Jorge; Vahey, Brendan R.; Henriques, Bruno; Benfatti, Cesar A. M.; Magini, Ricardo S.; López-López, José; Souza, Júlio C. M.

    2016-01-01

    The aim of this study was to conduct a literature review on the potential benefits with the use of Morse taper dental implant connections associated with small diameter platform switching abutments. A Medline bibliographical search (from 1961 to 2014) was carried out. The following search items were explored: “Bone loss and platform switching,” “bone loss and implant-abutment joint,” “bone resorption and platform switching,” “bone resorption and implant-abutment joint,” “Morse taper and platform switching.” “Morse taper and implant-abutment joint,” Morse taper and bone resorption,” “crestal bone remodeling and implant-abutment joint,” “crestal bone remodeling and platform switching.” The selection criteria used for the article were: meta-analysis; randomized controlled trials; prospective cohort studies; as well as reviews written in English, Portuguese, or Spanish languages. Within the 287 studies identified, 81 relevant and recent studies were selected. Results indicated a reduced occurrence of peri-implantitis and bone loss at the abutment/implant level associated with Morse taper implants and a reduced-diameter platform switching abutment. Extrapolation of data from previous studies indicates that Morse taper connections associated with platform switching have shown less inflammation and possible bone loss with the peri-implant soft tissues. However, more long-term studies are needed to confirm these trends. PMID:27011755

  1. Characterization of the High-Speed-Stage Bearing Skidding of Wind Turbine Gearboxes Induced by Dynamic Electricity Grid Events

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Helsen, Jan; Guillaume, Patrick; Guo, Yi

    Bearing behavior is an important factor for wind turbine drivetrain reliability. Extreme loads and dynamic excitations pose challenges to the bearing design and therefore its performance. Excessive skidding of the bearing rollers should be avoided because it can cause scuffing failures. Excitations coming from wind and the electricity grid can subject the drivetrain to fluctuating torque and nontorque loads. Wind-induced excitations have been investigated predominantly in literature. However, modern wind turbines are subjected more and more to grid-induced loads because of stricter electricity grid regulations. For example, during fault-ride-through events, turbines are required to stay connected for a longer periodmore » of time during the grid failure. This work investigates the influence of electrically induced excitations on the skidding behaviour of the tapered roller bearings on the high-speed stage of a wind turbine gearbox. This skidding behaviour during dynamic events is described as a potential bearing failure initiator by many researchers; however, only limited full-scale dynamic testing is documented. Therefore, a dedicated gridloss-type event is defined in the paper and conducted in a dynamometer test on a full-scale wind turbine nacelle. During the event, a complete electricity grid failure is simulated while the turbine is at rated speed and predefined torque levels. Particular focus is on the characterization of the high-speed shaft tapered roller bearing slip behavior. Strain-gauge bridges in grooves along the circumference of the outer ring are used to characterize the bearing load zone in detail. It is shown that during the torque reversals of the transient event, roller slip can be induced. This indicates the potential of the applied load case to go beyond the preload of the tapered roller bearing. Furthermore, the relation between the applied torque and skidding level is studied.« less

  2. Characterization of the High-Speed-Stage Bearing Skidding of Wind Turbine Gearboxes Induced by Dynamic Electricity Grid Events: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Helsen, Jan; Guillaume, Patrick; Guo, Yi

    Bearing behavior is an important factor for wind turbine drivetrain reliability. Extreme loads and dynamic excitations pose challenges to the bearing design and therefore its performance. Excessive skidding of the bearing rollers should be avoided because it can cause scuffing failures. Excitations coming from wind and the electricity grid can subject the drivetrain to fluctuating torque and nontorque loads. Wind-induced excitations have been investigated predominantly in literature. However, modern wind turbines are subjected more and more to grid-induced loads because of stricter electricity grid regulations. For example, during fault-ride-through events, turbines are required to stay connected for a longer periodmore » of time during the grid failure. This work investigates the influence of electrically induced excitations on the skidding behaviour of the tapered roller bearings on the high-speed stage of a wind turbine gearbox. This skidding behaviour during dynamic events is described as a potential bearing failure initiator by many researchers; however, only limited full-scale dynamic testing is documented. Therefore, a dedicated gridloss-type event is defined in the paper and conducted in a dynamometer test on a full-scale wind turbine nacelle. During the event, a complete electricity grid failure is simulated while the turbine is at rated speed and predefined torque levels. Particular focus is on the characterization of the high-speed shaft tapered roller bearing slip behavior. Strain-gauge bridges in grooves along the circumference of the outer ring are used to characterize the bearing load zone in detail. It is shown that during the torque reversals of the transient event, roller slip can be induced. This indicates the potential of the applied load case to go beyond the preload of the tapered roller bearing. Furthermore, the relation between the applied torque and skidding level is studied.« less

  3. Efficient Implementation of an Optimal Interpolator for Large Spatial Data Sets

    NASA Technical Reports Server (NTRS)

    Memarsadeghi, Nargess; Mount, David M.

    2007-01-01

    Interpolating scattered data points is a problem of wide ranging interest. A number of approaches for interpolation have been proposed both from theoretical domains such as computational geometry and in applications' fields such as geostatistics. Our motivation arises from geological and mining applications. In many instances data can be costly to compute and are available only at nonuniformly scattered positions. Because of the high cost of collecting measurements, high accuracy is required in the interpolants. One of the most popular interpolation methods in this field is called ordinary kriging. It is popular because it is a best linear unbiased estimator. The price for its statistical optimality is that the estimator is computationally very expensive. This is because the value of each interpolant is given by the solution of a large dense linear system. In practice, kriging problems have been solved approximately by restricting the domain to a small local neighborhood of points that lie near the query point. Determining the proper size for this neighborhood is a solved by ad hoc methods, and it has been shown that this approach leads to undesirable discontinuities in the interpolant. Recently a more principled approach to approximating kriging has been proposed based on a technique called covariance tapering. This process achieves its efficiency by replacing the large dense kriging system with a much sparser linear system. This technique has been applied to a restriction of our problem, called simple kriging, which is not unbiased for general data sets. In this paper we generalize these results by showing how to apply covariance tapering to the more general problem of ordinary kriging. Through experimentation we demonstrate the space and time efficiency and accuracy of approximating ordinary kriging through the use of covariance tapering combined with iterative methods for solving large sparse systems. We demonstrate our approach on large data sizes arising both from synthetic sources and from real applications.

  4. Deubiquitylating enzymes as cancer stem cell therapeutics.

    PubMed

    Haq, Saba; Suresh, Bharathi; Ramakrishna, Suresh

    2018-01-01

    The focus of basic and applied research on core stem cell transcription factors has paved the way to initial delineation of their characteristics, their regulatory mechanisms, and the applicability of their regulatory proteins for protein-induced pluripotent stem cells (protein-IPSC) generation and in further clinical settings. Striking parallels have been observed between cancer stem cells (CSCs) and stem cells. For the maintenance of stem cells and CSC pluripotency and differentiation, post translational modifications (i.e., ubiquitylation and deubiquitylation) are tightly regulated, as these modifications result in a variety of stem cell fates. The identification of deubiquitylating enzymes (DUBs) involved in the regulation of core stem cell transcription factors and CSC-related proteins might contribute to providing novel insights into the implications of DUB regulatory mechanisms for governing cellular reprogramming and carcinogenesis. Moreover, we propose the novel possibility of applying DUBs coupled with core transcription factors to improve protein-iPSC generation efficiency. Additionally, this review article further illustrates the potential of applying DUB inhibitors as a novel therapeutic intervention for targeting CSCs. Thus, defining DUBs as core pharmacological targets implies that future endeavors to develop their inhibitors may revolutionize our ability to regulate stem cell maintenance and differentiation, somatic cell reprogramming, and cancer stem cells. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Development of a photogrammetric method of measuring tree taper outside bark

    Treesearch

    David R. Larsen

    2006-01-01

    A photogrammetric method is presented for measuring tree diameters outside bark using calibrated control ground-based digital photographs. The method was designed to rapidly collect tree taper information from subject trees for the development of tree taper equations. Software that is commercially available, but designed for a different purpose, can be readily adapted...

  6. Taper models for commercial tree species in the northeastern United States

    Treesearch

    James A. Westfall; Charles T. Scott

    2010-01-01

    A new taper model was developed based on the switching taper model of Valentine and Gregoire; the most substantial changes were reformulation to incorporate estimated join points and modification of a switching function. Random-effects parameters were included that account for within-tree correlations and allow for customized calibration to each individual tree. The...

  7. Thin-Ribbon Tapered Couplers For Dielectric Waveguides

    NASA Technical Reports Server (NTRS)

    Otoshi, Tom Y.; Shimabukuro, Fred I.; Yeh, Cavour

    1996-01-01

    Thin-ribbon tapered couplers proposed for launching electro-magnetic waves into dielectric waveguides, which include optical fibers. Intended for use with ribbon dielectric waveguides designed for operation at millimeter or submillimeter wavelengths, made of high-relative-permittivity, low-loss materials and thicknesses comparable to or less than free-space design wavelengths. Coupling efficiencies exceeds those of older tapered couplers.

  8. Tapered fibers embedded in silica aerogel.

    PubMed

    Xiao, Limin; Grogan, Michael D W; Leon-Saval, Sergio G; Williams, Rhys; England, Richard; Wadsworth, Willam J; Birks, Tim A

    2009-09-15

    We have embedded thin tapered fibers (with diameters down to 1 microm) in silica aerogel with low loss. The aerogel is rigid but behaves refractively like air, protecting the taper without disturbing light propagation along it. This enables a new class of fiber devices exploiting volume evanescent interactions with the aerogel itself or with dopants or gases in the pores.

  9. Biomechanical Three-Dimensional Finite Element Analysis of Single Implant-Supported Prostheses in the Anterior Maxilla, with Different Surgical Techniques and Implant Types.

    PubMed

    Verri, Fellippo Ramos; Santiago, Joel Ferreira; Almeida, Daniel Augusto; de Souza Batista, Victor Eduardo; Araujo Lemos, Cleidiel Aparecido; Mello, Caroline Cantieri; Pellizzer, Eduardo Piza

    The aim of this study was to use three-dimensional finite element analysis to analyze the stress distribution transferred by single implant-supported prostheses placed in the anterior maxilla using different connections (external hexagon, internal hexagon, or Morse taper), inclinations of the load (0, 30, or 60 degrees), and surgical techniques for placement (monocortical/conventional, bicortical, or bicortical with nasal floor elevation). Nine models representing a bone block of this region were simulated by computer-aided design software (InVesalius, Rhinoceros, SolidWorks). Each model received one implant, which supported a cemented metalloceramic crown. Using FEMAP software, finite elements were discretized while simulating a 178-N load at 0, 30, and 60 degrees relative to the long axis of the implant. The problem was solved in NEi Nastran software, and postprocessing was performed in FEMAP. Von Mises stress and maximum principal stress maps were made. The von Mises stress analysis revealed that stress increased with increasing inclination of the load, from 0 to 30 to 60 degrees. Morse taper implants showed less stress concentration around the cervical and apical areas of the implant. The bicortical technique, associated or not with nasal floor elevation, contributed to decreasing the stress concentration in the apical area of the implant. Maximum principal stress analysis showed that the increase in inclination was proportional to the increase in stress on the bone tissue in the cervical area. Lower stress concentrations in the cortical bone were obtained with Morse taper implants and the bicortical technique compared with other connections and surgical techniques, respectively. Increasing the inclination of the applied force relative to the long axis of the implant tended to overload the peri-implant bone tissue and the internal structure of the implants. The Morse taper connection and bicortical techniques seemed to be more favorable than other connections or techniques, respectively, for restoring the anterior maxilla.

  10. Salivary hormones, IgA, and performance during intense training and tapering in judo athletes.

    PubMed

    Papacosta, Elena; Gleeson, Michael; Nassis, George P

    2013-09-01

    The aims of this study were to identify the time course of change of salivary testosterone (sT), cortisol (sC), and IgA (SIgA); mood state; and performance capacity during a 2-week taper in judo athletes and to examine the diurnal variation in these salivary markers. Eleven male judo athletes completed 5 weeks of training: 1 week of normal training (NORM), 2 weeks of intensified training (INT), and 2 weeks of exponential tapering (TAPER). Once per week subjects completed vertical and horizontal countermovement jump tests, a grip strength test, a Special Judo Fitness Test, a multistage aerobic fitness test, a 3 × 300-m run test, and anthropometric measurement. Subjects also completed questionnaires to assess mood state and muscle soreness. Two daily saliva samples (at 0700 and 1900) were collected at the end of each week during NORM and INT and every day during TAPER. Increased morning sT, decreased evening sC, lower muscle soreness, and enhanced mood state (p < 0.05) were evident by the early phases of TAPER. A significant 7.0% improvement in 3 × 300-m performance time, a 6.9% improvement in the vertical jump (p < 0.05), and increased morning and evening SIgA secretion rate (p < 0.01) were observed during the middle-late phases of TAPER. The higher values of salivary variables were observed in the morning. This study indicates that salivary hormones display diurnal variation. Furthermore, changes in hormonal responses, mood state, and muscle soreness precede enhancements in performance and mucosal immunity, suggesting that judo athletes taper for at least a week before competition.

  11. Efficiency considerations for the purely tapered interference fit (TIF) abutments used in dental implants.

    PubMed

    Bozkaya, Dinçer; Müftü, Sinan

    2004-08-01

    A tapered interference fit provides a mechanically reliable retention mechanism for the implant-abutment interface in a dental implant. Understanding the mechanical properties of the tapered interface with or without a screw at the bottom has been the subject of a considerable amount of studies involving experiments and finite element (FE) analysis. In this paper, approximate closed-form formulas are developed to analyze the mechanics of a tapered interference fit. In particular, the insertion force, the efficiency, defined as the ratio of the pull-out force to insertion force, and the critical insertion depth, which causes the onset of plastic deformation, are analyzed. It is shown that the insertion force is a function of the taper angle, the contact length, the inner and outer radii of the implant, the static and the kinetic coefficients of friction, and the elastic modulii of the implant/abutment materials. The efficiency of the tapered interference fit, which is defined as the ratio of the pull-out force to insertion force, is found to be greater than one, for taper angles that are less than 6 deg when the friction coefficient is 0.3. A safe range of insertion forces has been shown to exist. The lower end of this range depends on the maximum pull-out force that may occur due to occlusion in the multiple tooth restorations and the efficiency of the system; and the upper end of this range depends on the plastic deformation of the abutment and the implant due to interference fit. It has been shown that using a small taper angle and a long contact length widens the safe range of insertion forces.

  12. Tuning micropillar tapering for optimal friction performance of thermoplastic gecko-inspired adhesive.

    PubMed

    Kim, Yongkwan; Chung, Yunsie; Tsao, Angela; Maboudian, Roya

    2014-05-14

    We present a fabrication method and friction testing of a gecko-inspired thermoplastic micropillar array with control over the tapering angle of the pillar sidewall. A combination of deep reactive ion etching of vertical silicon pillars and subsequent maskless chemical etching produces templates with various widths and degrees of taper, which are then replicated with low-density polyethylene. As the silicon pillars on the template are chemically etched in a bath consisting of hydrofluoric acid, nitric acid, and acetic acid (HNA), the pillars are progressively thinned, then shortened. The replicated polyethylene pillar arrays exhibit a corresponding increase in friction as the stiffness is reduced with thinning and then a decrease in friction as the stiffness is again increased. The dilution of the HNA bath in water influences the tapering angle of the silicon pillars. The friction of the replicated pillars is maximized for the taper angle that maximizes the contact area at the tip which in turn is influenced by the stiffness of the tapered pillars. To provide insights on how changes in microscale geometry and contact behavior may affect friction of the pillar array, the pillars are imaged by scanning electron microscopy after friction testing, and the observed deformation behavior from shearing is related to the magnitude of the macroscale friction values. It is shown that the tapering angle critically changes the pillar compliance and the available contact area. Simple finite element modeling calculations are performed to support that the observed deformation is consistent with what is expected from a mechanical analysis. We conclude that friction can be maximized via proper pillar tapering with low stiffness that still maintains enough contact area to ensure high adhesion.

  13. Thulium fiber laser lithotripsy using tapered fibers.

    PubMed

    Blackmon, Richard L; Irby, Pierce B; Fried, Nathaniel M

    2010-01-01

    The Thulium fiber laser has recently been tested as a potential alternative to the Holmium:YAG laser for lithotripsy. This study explores use of a short taper for expanding the Thulium fiber laser beam at the distal tip of a small-core fiber. Thulium fiber laser radiation with a wavelength of 1,908 nm, 10 Hz pulse rate, 70 mJ pulse energy, and 1-millisecond pulse duration was delivered through a 2-m-length fiber with 150-microm-core-input-end, 300-microm-core-output-end, and 5-mm-length taper, in contact with human uric acid (UA) and calcium oxalate monohydrate (COM) stones, ex vivo (n = 10 each). Stone mass loss, stone crater depths, fiber transmission losses, fiber burn-back, irrigation rates, and deflection through a flexible ureteroscope were measured for the tapered fiber and compared with conventional fibers. After delivery of 1,800 pulses through the tapered fiber, mass loss measured 12.7+/-2.6 mg for UA and 7.2+/-0.8 mg COM stones, comparable to conventional 100-microm-core fibers (12.6+/-2.5 mg for UA and 6.8+/-1.7 mg for COM stones). No transmission losses or burn-back occurred for the tapered fiber after 36,000 pulses, while a conventional 150-microm fiber experienced significant tip degradation after only 1,800 pulses. High irrigation rates were measured with the tapered fiber inserted through the working port of a flexible ureteroscope without hindering its deflection, mimicking that of a conventional 150 microm fiber. The short tapered distal fiber tip allows expansion of the laser beam, resulting in decreased fiber tip damage compared to conventional small-core fibers, without compromising fiber bending, stone vaporization efficiency, or irrigation rates.

  14. Fatigue delamination onset prediction in tapered composite laminates

    NASA Technical Reports Server (NTRS)

    Murri, Gretchen Bostaph; Salpekar, Satish A.; Obrien, T. Kevin

    1989-01-01

    Tapered (0 deg) laminates of S2/CE9000 and S2/SP250 glass/epoxies, and IM6/1827I graphite/epoxy were tested in cyclic tension. The specimens usually showed some initial stable delaminations in the tapered region, but these did not affect the stiffness of the specimens, and loading was continued until the specimens either delaminated unstably, or reached 10(exp 6) to 2 x 10(exp 7) million cycles with no unstable delamination. The final unstable delamination originated at the junction of the thin and tapered regions. A finite-element model was developed for the tapered laminate with and without the initial stable delaminations observed in the tests. The analysis showed that for both cases the most likely place for an opening (Mode 1) delamination to originate is at the junction of the taper and thin regions. For each material type, the models were used to calculate the strain energy release rate, G, associated with delaminations originating at that junction and growing either into the thin region or tapered region. For the materials tested, cyclic G(sub Imax) values from DCB tests were used with the maximum strain energy release rates calculated from the finite-element analysis to predict the onset of unstable delamination at the junction as a function of fatigue cycles. The predictions were compared to experimental values of maximum cyclic load as a function of cycles to unstable delamination from fatigue tests in tapered laminates. For the IM6/1827I and S2/SP250 laminates, the predictions agreed very well with the test data. Predicted values for the S2/CE9000 were conservative compared to the test data.

  15. Experimental Investigation of Bearing Slip in a Wind Turbine Gearbox During a Transient Grid Loss Event

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Helsen, Jan; Guo, Yi; Keller, Jonathan

    This work investigates the behaviour of the high speed stage of a wind turbine gearbox during a transient grid loss event. Dynamometer testing on a full scale wind turbine nacelle is used. A combination of external and internal gearbox measurements is analysed. Particular focus is on the characterization of the high speed shaft tapered roller bearing slip behaviour. This slipping behaviour is linked to dynamic events by many researchers and described as potential bearing failure initiator. However only limited full scale dynamic testing is documented. Strain gauge bridges in grooves along the circumference of the outer ring are used tomore » characterize the bearing behaviour in detail. It is shown that during the transient event the high speed shaft experiences a combined torsional and bending deformation. These unfavourable loading conditions induce roller slip in the bearings during the torque reversals indicating the potential of the applied load case to go beyond the preload of the tapered roller bearing.« less

  16. Design, fabrication, and operation of a test rig for high-speed tapered-roller bearings

    NASA Technical Reports Server (NTRS)

    Signer, H. R.

    1974-01-01

    A tapered-roller bearing test machine was designed, fabricated and successfully operated at speeds to 20,000 rpm. Infinitely variable radial loads to 26,690 N (6,000 lbs.) and thrust loads to 53,380 N (12,000 lbs.) can be applied to test bearings. The machine instrumentation proved to have the accuracy and reliability required for parametric bearing performance testing and has the capability of monitoring all programmed test parameters at continuous operation during life testing. This system automatically shuts down a test if any important test parameter deviates from the programmed conditions, or if a bearing failure occurs. A lubrication system was developed as an integral part of the machine, capable of lubricating test bearings by external jets and by means of passages feeding through the spindle and bearing rings into the critical internal bearing surfaces. In addition, provisions were made for controlled oil cooling of inner and outer rings to effect the type of bearing thermal management that is required when testing at high speeds.

  17. Cleaning Effectiveness of a Reciprocating Single-file and a Conventional Rotary Instrumentation System.

    PubMed

    de Carvalho, Fredson Marcio Acris; Gonçalves, Leonardo Cantanhede de Oliveira; Marques, André Augusto Franco; Alves, Vanessa; Bueno, Carlos Eduardo da Silveira; De Martin, Alexandre Sigrist

    2016-01-01

    To compare cleaning effectiveness by histological analysis of a reciprocating single-file system with ProTaper rotary instruments during the preparation of curved root canals in extracted teeth. A total of 40 root canals with curvatures ranging between 20 - 40 degrees were divided into two groups of 20 canals. Canals were prepared to the following apical sizes: Reciproc size 25 (n=20); ProTaper: F2 (n=20). The normal distribution of data was tested by the Kolmogorov-Smirnov test and the values obtained for the test (Mann-Whitney U test, P < .05) were statistically analyzed using the GraphPad InStat for the Mac OS software (GraphPad Software, La Jolla, CA, USA). There were no significant differences in remaining debris (P > .05) between the two groups. The application of reciprocating motion during instrumentation did not result in increased debris when compared with continuous rotation motion, even in the apical part of curved canals. Both instruments resulted in debris in the canal lumen, irrespective of the movement kinematics applied.

  18. Nonimaging optics in luminescent solar concentration.

    PubMed

    Markman, B D; Ranade, R R; Giebink, N C

    2012-09-10

    Light trapped within luminescent solar concentrators (LSCs) is naturally limited in angular extent by the total internal reflection critical angle, θcrit, and hence the principles of nonimaging optics can be leveraged to increase LSC concentration ratio by appropriately reshaping the edges. Here, we use rigorous ray-tracing simulations to explore the potential of this concept for realistic LSCs with compound parabolic concentrator (CPC)-tapered edges and show that, when applied to a single edge, the concentration ratio is increased by 23% while maintaining >90% of the original LSC optical efficiency. Importantly, we find that CPC-tapering all of the edges enables a significantly greater intensity enhancement up to 35% at >90% of the original optical efficiency, effectively enabling two-dimensional concentration through a cooperative, ray-recycling effect in which rays rejected by one CPC are accepted by another. These results open up a significant opportunity to improve LSC performance at virtually no added manufacturing cost by incorporating nonimaging optics into their design.

  19. Propagation of atmospheric-pressure ionization waves along the tapered tube

    NASA Astrophysics Data System (ADS)

    Xia, Yang; Wang, Wenchun; Liu, Dongping; Yan, Wen; Bi, Zhenhua; Ji, Longfei; Niu, Jinhai; Zhao, Yao

    2018-02-01

    Gas discharge in a small radius dielectric tube may result in atmospheric pressure plasma jets with high energy and density of electrons. In this study, the atmospheric pressure ionization waves (IWs) were generated inside a tapered tube. The propagation behaviors of IWs inside the tube were studied by using a spatially and temporally resolved optical detection system. Our measurements show that both the intensity and velocity of the IWs decrease dramatically when they propagate to the tapered region. After the taper, the velocity, intensity, and electron density of the IWs are improved with the tube inner diameter decreasing from 4.0 to 0.5 mm. Our analysis indicates that the local gas conductivity and surface charges may play a role in the propagation of the IWs under such a geometrical constraint, and the difference in the dynamics of the IWs after the taper can be related to the restriction in the size of IWs.

  20. Spectral tunability of two-photon states generated by spontaneous four-wave mixing: fibre tapering, temperature variation and longitudinal stress

    NASA Astrophysics Data System (ADS)

    Ortiz-Ricardo, E.; Bertoni-Ocampo, C.; Ibarra-Borja, Z.; Ramirez-Alarcon, R.; Cruz-Delgado, D.; Cruz-Ramirez, H.; Garay-Palmett, K.; U'Ren, A. B.

    2017-09-01

    We explore three different mechanisms designed to controllably tune the joint spectrum of photon pairs produced by the spontaneous four-wave mixing (SFWM) process in optical fibres. The first of these is fibre tapering, which exploits the modified optical dispersion resulting from reducing the core radius. We have presented a theory of SFWM for tapered fibres, as well as experimental results for the SFWM coincidence spectra as a function of the reduction in core radius due to tapering. The other two techniques that we have explored are temperature variation and application of longitudinal stress. While the maximum spectral shift observed with these two techniques is smaller than for fibre tapering, they are considerably simpler to implement and have the important advantage that they are based on the use of a single, suitably controlled, fibre specimen.

  1. Eigenvalue equation and core-mode cutoff of weakly guiding tapered fiber as three layer optical waveguide and used as biochemical sensor.

    PubMed

    Linslal, C L; Mohan, P M S; Halder, A; Gangopadhyay, T K

    2012-06-01

    The core-mode cutoff plays a major role in evanescent field absorption based sensors. A method has been proposed to calculate the core-mode cutoff by solving the eigenvalue equations of a weakly guiding three layer optical waveguide graphically. The variation of normalized waveguide parameter (V) is also calculated with different wavelengths at core-mode cutoff. At the first step, theoretical analysis of tapered fiber parameters has been performed for core-mode cutoff. The taper angle of an adiabatic tapered fiber is also analyzed using the length-scale criterion. Secondly, single-mode tapered fiber has been developed to make a precision sensor element suitable for chemical detection. Finally, the sensor element has been used to detect absorption peak of ethylenediamine. Results are presented in which an absorption peak at 1540 nm is observed.

  2. Tapered optical fiber waveguide coupling to whispering gallery modes of liquid crystal microdroplet for thermal sensing application.

    PubMed

    Wang, Yan; Li, Hanyang; Zhao, Liyuan; Liu, Yongjun; Liu, Shuangqiang; Yang, Jun

    2017-01-23

    We demonstrate efficient coupling to the optical whispering gallery modes (WGMs) of nematic liquid crystal (NLC) microdroplets immersed in an immiscible aqueous environment. An individual NLC microdroplet, confined at the tip of a microcapillary, was coupled via a tapered optical fiber waveguide positioned correctly within its vicinity. Critical coupling of the taper-microdroplet system was facilitated by adjusting the gap between the taper and the microdroplet to change the overlap of the evanescent electromagnetic fields; efficient and controlled power transfer from the taper waveguide to the NLC microdroplet is indeed possible via the proposed technique. We also found that NLC microdroplets can function as highly sensitive thermal sensors: A maximum temperature sensitivity of 267.6 pm/°C and resolution of 7.5 × 10-2 °C were achieved in a 78-μm-diameter NLC microdroplet.

  3. Physicochemical Control of Adult Stem Cell Differentiation: Shedding Light on Potential Molecular Mechanisms

    DTIC Science & Technology

    2010-01-01

    stem - cell -based biomedical and therapeutic applications, including tissue engineering, requires an understanding of the cell-cell and cell-environment interactions. To this end, recent efforts have been focused on the manipulation of adult stem cell differentiation using inductive soluble factors, designing suitable mechanical environments, and applying noninvasive physical forces. Although each of these different approaches has been successfully applied to regulate stem cell differentiation, it would be of great interest and

  4. Simulation on friction taper plug welding of AA6063-20Gr metal matrix composite

    NASA Astrophysics Data System (ADS)

    Hynes, N. Rajesh Jesudoss; Nithin, Abeyram M.

    2016-05-01

    Friction taper plug welding a variant of friction welding is useful in welding of similar and dissimilar materials. It could be used for joining of composites to metals in sophisticated aerospace applications. In the present work numerical simulation of friction taper plug welding process is carried out using finite element based software. Graphite reinforced AA6063 is modelled using the software ANSYS 15.0 and temperature distribution is predicted. Effect of friction time on temperature distribution is numerically investigated. When the friction time is increased to 30 seconds, the tapered part of plug gets detached and fills the hole in the AA6063 plate perfectly.

  5. Vector rectangular-shape laser based on reduced graphene oxide interacting with a long fiber taper.

    PubMed

    Gao, Lei; Zhu, Tao; Huang, Wei; Zeng, Jing

    2014-10-01

    A vector dual-wavelength rectangular-shape laser (RSL) based on a long fiber taper deposited with reduced graphene oxide is proposed, where nonlinearity is enhanced due to a large evanescent-field-interacting length and strong field confinement of an 8 mm fiber taper with a waist diameter of 4 μm. Graphene flakes are deposited uniformly on the taper waist with light pressure effect, so this structure guarantees both excellent saturable absorption and high nonlinearity. The RSL with a repetition rate of 7.9 MHz shows fast polarization switching in two orthogonal polarization directions, and temporal and spectral characteristics are investigated.

  6. Note on performance of tapered grip tensile loading devices

    NASA Technical Reports Server (NTRS)

    Jones, M. H.; Brown, W. F., Jr.

    1975-01-01

    Alignment results are presented in terms of percent bending for a quick release, tapered grip, tensile loading device that has been proposed for testing sharply notched specimens of aluminum and magnesium alloys by a Task Group of the ASTM Committee E-24 on Fracture Testing of Metals. The results show that the bending introduced by the fixtures is strongly dependent on their relative rotational positions in respect to the loading rods which adapt them, to the tensile machine. For one set of tapered grips the highest bending was about 15%. Recommendations are made for improvement in the design of the tapered grips which should reduce the bending stresses substantially.

  7. Development of small bore, high speed tapered roller bearing

    NASA Technical Reports Server (NTRS)

    Morrison, F. R.; Gassel, S. S.; Bovenkerk, R. L.

    1981-01-01

    The performance of four rolling bearing configurations for use on the input pinion shaft of a proposed commercial helicopter transmission was evaluated. The performance characteristics of a high speed tapered roller bearing operating under conditions comparable to those existing at this input pinion shaft were defined. The tapered roller bearing shaft support configuration was developed for the gearbox using commercially available bearing designings. The configuration was optimized and interactive thermomechanically system analyzed. Automotive pinion quality tapered roller bearings were found to be reliable under load and speed conditions in excess of those anticipated in the helicopter transmission. However, it is indicated that the elastohydrodynamic lubricant films are inadequate.

  8. Tunable optofluidic microring laser based on a tapered hollow core microstructured optical fiber.

    PubMed

    Li, Zhi-Li; Zhou, Wen-Yuan; Luo, Ming-Ming; Liu, Yan-Ge; Tian, Jian-Guo

    2015-04-20

    A tunable optofluidic microring dye laser within a tapered hollow core microstructured optical fiber was demonstrated. The fiber core was filled with a microfluidic gain medium plug and axially pumped by a nanosecond pulse laser at 532 nm. Strong radial emission and low-threshold lasing (16 nJ/pulse) were achieved. Lasing was achieved around the surface of the microfluidic plug. Laser emission was tuned by changing the liquid surface location along the tapered fiber. The possibility of developing a tunable laser within the tapered simplified hollow core microstructured optical fiber presents opportunities for developing liquid surface position sensors and biomedical analysis.

  9. Optical microscope and tapered fiber coupling apparatus for a dilution refrigerator.

    PubMed

    MacDonald, A J R; Popowich, G G; Hauer, B D; Kim, P H; Fredrick, A; Rojas, X; Doolin, P; Davis, J P

    2015-01-01

    We have developed a system for tapered fiber measurements of optomechanical resonators inside a dilution refrigerator, which is compatible with both on- and off-chip devices. Our apparatus features full three-dimensional control of the taper-resonator coupling conditions enabling critical coupling, with an overall fiber transmission efficiency of up to 70%. Notably, our design incorporates an optical microscope system consisting of a coherent bundle of 37,000 optical fibers for real-time imaging of the experiment at a resolution of ∼1 μm. We present cryogenic optical and optomechanical measurements of resonators coupled to tapered fibers at temperatures as low as 9 mK.

  10. Temperature-independent refractometer based on a tapered photonic crystal fiber interferometer

    NASA Astrophysics Data System (ADS)

    Ni, Kai; Chan, Chi Chiu; Dong, Xinyong; Poh, C. L.; Li, Tao

    2013-03-01

    A temperature-independent refractometer by using a tapered photonic crystal fiber (PCF) based Mach-Zehnder interferometer (MZI) is proposed and experimentally demonstrated. It is fabricated by sandwiching a tapered PCF of 29 mm long between two standard single mode fibers (SMFs) with the fully collapsed air holes of the PCF in the fusion splicing region. It has been found that tapering the PCF greatly enhances the sensitivity of the refractometer. A maximum sensitivity of 1529 nm/RIU (refractive index unit) is achieved within the range from 1.3355 to 1.413. The refractometer is nearly temperature-insensitive due to the ultra low temperature dependence of the used.

  11. Combined tension and bending testing of tapered composite laminates

    NASA Astrophysics Data System (ADS)

    O'Brien, T. Kevin; Murri, Gretchen B.; Hagemeier, Rick; Rogers, Charles

    1994-11-01

    A simple beam element used at Bell Helicopter was incorporated in the Computational Mechanics Testbed (COMET) finite element code at the Langley Research Center (LaRC) to analyze the responce of tappered laminates typical of flexbeams in composite rotor hubs. This beam element incorporated the influence of membrane loads on the flexural response of the tapered laminate configurations modeled and tested in a combined axial tension and bending (ATB) hydraulic load frame designed and built at LaRC. The moments generated from the finite element model were used in a tapered laminated plate theory analysis to estimate axial stresses on the surface of the tapered laminates due to combined bending and tension loads. Surfaces strains were calculated and compared to surface strains measured using strain gages mounted along the laminate length. The strain distributions correlated reasonably well with the analysis. The analysis was then used to examine the surface strain distribution in a non-linear tapered laminate where a similarly good correlation was obtained. Results indicate that simple finite element beam models may be used to identify tapered laminate configurations best suited for simulating the response of a composite flexbeam in a full scale rotor hub.

  12. Adaptable Optical Fiber Displacement-Curvature Sensor Based on a Modal Michelson Interferometer with a Tapered Single Mode Fiber

    PubMed Central

    Salceda-Delgado, G.; Martinez-Rios, A.; Selvas-Aguilar, R.; Álvarez-Tamayo, R. I.; Castillo-Guzman, A.; Ibarra-Escamilla, B.; Durán-Ramírez, V. M.; Enriquez-Gomez, L. F.

    2017-01-01

    A compact, highly sensitive optical fiber displacement and curvature radius sensor is presented. The device consists of an adiabatic bi-conical fused fiber taper spliced to a single-mode fiber (SMF) segment with a flat face end. The bi-conical taper structure acts as a modal coupling device between core and cladding modes for the SMF segment. When the bi-conical taper is bent by an axial displacement, the symmetrical bi-conical shape of the tapered structure is stressed, causing a change in the refractive index profile which becomes asymmetric. As a result, the taper adiabaticity is lost, and interference between modes appears. As the bending increases, a small change in the fringe visibility and a wavelength shift on the periodical reflection spectrum of the in-fiber interferometer is produced. The displacement sensitivity and the spectral periodicity of the device can be adjusted by the proper selection of the SMF length. Sensitivities from around 1.93 to 3.4 nm/mm were obtained for SMF length between 7.5 and 12.5 cm. Both sensor interrogations, wavelength shift and visibility contrast, can be used to measure displacement and curvature radius magnitudes. PMID:28574421

  13. Adaptable Optical Fiber Displacement-Curvature Sensor Based on a Modal Michelson Interferometer with a Tapered Single Mode Fiber.

    PubMed

    Salceda-Delgado, G; Martinez-Rios, A; Selvas-Aguilar, R; Álvarez-Tamayo, R I; Castillo-Guzman, A; Ibarra-Escamilla, B; Durán-Ramírez, V M; Enriquez-Gomez, L F

    2017-06-02

    A compact, highly sensitive optical fiber displacement and curvature radius sensor is presented. The device consists of an adiabatic bi-conical fused fiber taper spliced to a single-mode fiber (SMF) segment with a flat face end. The bi-conical taper structure acts as a modal coupling device between core and cladding modes for the SMF segment. When the bi-conical taper is bent by an axial displacement, the symmetrical bi-conical shape of the tapered structure is stressed, causing a change in the refractive index profile which becomes asymmetric. As a result, the taper adiabaticity is lost, and interference between modes appears. As the bending increases, a small change in the fringe visibility and a wavelength shift on the periodical reflection spectrum of the in-fiber interferometer is produced. The displacement sensitivity and the spectral periodicity of the device can be adjusted by the proper selection of the SMF length. Sensitivities from around 1.93 to 3.4 nm/mm were obtained for SMF length between 7.5 and 12.5 cm. Both sensor interrogations, wavelength shift and visibility contrast, can be used to measure displacement and curvature radius magnitudes.

  14. A comparative analysis of salivary factors and maxillary denture retention in different arch forms: An in vivo study.

    PubMed

    Shekhar, Abhishek; Das, Samiran; Bhattacharyya, Jayanta; Goel, Preeti; Majumdar, Sayan; Ghosh, Soumitra

    2018-01-01

    This study aims to find the effect of change in different salivary factors before and after complete denture insertion and to measure the maxillary denture retention in different arch forms. Thirty completely edentulous individuals (10 each of square, tapered, and ovoid arch form of maxilla) belonging to the age group of 40-70 years were selected. Salivary factors (flow, density, pH, viscosity, and total protein) were evaluated before and after denture insertion. Retention of maxillary denture was measured in all the different arch forms. Student's independent sample's t -test was applied. The correlation was analyzed by Pearson's correlation analysis. While mean flow rate and pH of saliva increased, mean viscosity, total protein, and density of saliva decreased after maxillary complete denture insertion. A positive correlation was found between retention and total maxillary basal surface area. Retention value was found to be greatest in square type and least in tapered type. Complete denture acts as a mechanical stimulant thus increasing flow rate and pH immediately after complete denture insertion. Density, total protein, and viscosity of saliva decreased after complete denture insertion which may be due to increase in water content of saliva. The retention of maxillary complete denture does not seem to depend on the rate of change of the salivary factors, before and after complete denture insertion. Total basal surface area and maxillary denture retention values were highest in square arch form and least in tapered arch form.

  15. An In vitro Comparison of Apically Extruded Debris Using Reciproc, ProTaper Universal, Neolix and Hyflex in Curved Canals

    PubMed Central

    Labbaf, Hossein; Nazari Moghadam, Kiumars; Shahab, Shahriar; Mohammadi Bassir, Mahshid; Fahimi, Mohammad Amin

    2017-01-01

    Introduction: As a consequence of root canal preparation, dentinal chips, irrigants and pulp remnants are extruded into preradicular space. This phenomenon may lead to post endodontic flare-ups. The purpose of this study was to compare the amount of extruded debris with four endodontic NiTi engine-driven systems. Methods and Materials: Sixty mesiobuccal roots of maxillary molars with 15-30˚ curvature were divided randomly into four groups (n=15). Each group was instrumented up to apical size of 25 using Reciproc, ProTaper Universal, Neolix and Hyflex. Bidistilled water was used as irrigant and extruded debris was collected in pre-weighted Eppendorf tubes. Tubes were stored in incubator for drying the debris. Extruded debris were weighted in electronic microbalance with accuracy of 0.0001 g. The raw data was analyzed with one way analysis of variance (ANOVA) and Tukey’s HSD post hoc test. Level of significance was set at 0.05. Results: The debris extrusion with Reciproc files was significantly higher than the other groups (P<0.05). Hyflex significantly extruded less debris than other files (P<0.05). There was no significant difference between ProTaper Universal and Neolix regarding the amount of extruded debris (P=0.98). Conclusion: All systems extruded debris during the instrumentation. Reciproc system significantly extruded more debris. Caution should be taken when interpreting the results of this study and applying it to the real clinical situation. PMID:28808456

  16. 2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla.

    PubMed

    Desai, Shrikar R; Singh, Rika; Karthikeyan, I

    2013-09-01

    The aim of the study is to evaluate the influence implant length on stress distribution at bone implant interface in single immediately loaded implants when placed in D4 bone quality. A 2-dimensional finite element models were developed to simulate two types of implant designs, standard 3.75 mm-diameter tapered body implants of 6 and 10 mm lengths. The implants were placed in D4 bone quality with a cortical bone thickness of 0.5 mm. The implant design incorporated microthreads at the crestal part and the rest of the implant body incorporated Acme threads. The Acme thread form has a 29° thread angle with a thread height half of the pitch; the apex and valley are flat. A 100 N of force was applied vertically and in the oblique direction (at an angle of 45°) to the long axis of the implants. The respective material properties were assigned. Micro-movements and stresses at the bone implant interface were evaluated. The results of total deformation (micro-movement) and Von mises stress were found to be lower for tapered long implant (10 mm) than short implant (6 mm) while using both vertical as well as oblique loading. Short implants can be successfully placed in poor bone quality under immediate loading protocol. The novel approach of the combination of microthreads at the crestal portion and acme threads for body portion of implant fixture gave promising results.

  17. High-temperature, high-pressure bonding of nested tubular metallic components

    DOEpatents

    Quinby, Thomas C.

    1980-01-01

    This invention is a tool for effecting high-temperature, high-compression bonding between the confronting faces of nested, tubular, metallic components. In a typical application, the tool is used to produce tubular target assemblies for irradiation in nuclear reactors or particle accelerators, the target assembly comprising a uranium foil and an aluminum-alloy substrate. The tool preferably is composed throughout of graphite. It comprises a tubular restraining member in which a mechanically expandable tubular core is mounted to form an annulus with the member. The components to be bonded are mounted in nested relation in the annulus. The expandable core is formed of individually movable, axially elongated segments whose outer faces cooperatively define a cylindrical pressing surface and whose inner faces cooperatively define two opposed, inwardly tapered, axial bores. Tapered rams extend respectively into the bores. The loaded tool is mounted in a conventional hot-press provided with evacuation means, heaters for maintaining its interior at bonding temperature, and hydraulic cylinders for maintaining a selected inwardly directed pressure on the tapered rams. With the hot-press evacuated and the loaded tool at the desired temperature, the cylinders are actuated to apply the selected pressure to the rams. The rams in turn expand the segmented core to maintain the nested components in compression against the restraining member. These conditions are maintained until the confronting faces of the nested components are joined in a continuous, uniform bond characterized by high thermal conductivity.

  18. Tapering Courses of Oral Vancomycin Induce Persistent Disruption of the Microbiota That Provide Colonization Resistance to Clostridium difficile and Vancomycin-Resistant Enterococci in Mice.

    PubMed

    Tomas, Myreen E; Mana, Thriveen S C; Wilson, Brigid M; Nerandzic, Michelle M; Joussef-Piña, Samira; Quiñones-Mateu, Miguel E; Donskey, Curtis J

    2018-05-01

    Vancomycin taper regimens are commonly used for the treatment of recurrent Clostridium difficile infections. One rationale for tapering and pulsing of the dose at the end of therapy is to reduce the selective pressure of vancomycin on the indigenous intestinal microbiota. Here, we used a mouse model to test the hypothesis that the indigenous microbiota that provide colonization resistance against C. difficile and vancomycin-resistant enterococci (VRE) is repopulated during tapering courses of vancomycin. Mice were treated orally with vancomycin daily for 10 days, vancomycin in a tapering dose for 42 days, fidaxomicin for 10 days, or saline. To assess colonization resistance, subsets of mice were challenged with 10 4 CFU of C. difficile or VRE at multiple time points during and after completion of treatment. The impact of the treatments on the microbiome was measured by cultures, real-time PCR for selected anaerobic bacteria, and deep sequencing. Vancomycin taper-treated mice developed alterations of the microbiota and disruption of colonization resistance that was persistent 18 days after treatment. In contrast, mice treated with a 10-day course of vancomycin exhibited recovery of the microbiota and of colonization resistance by 15 days after treatment, and fidaxomicin-treated mice maintained intact colonization resistance. These findings demonstrate that alteration of the indigenous microbiota responsible for colonization resistance to C. difficile and VRE persist during and after completion of tapering courses of vancomycin. Copyright © 2018 American Society for Microbiology.

  19. Evaluation of Root Canal Cleaning and Shaping Efficacy of Three Engine-driven Instruments: SafeSider, ProTaper Universal and Lightspeed LSX.

    PubMed

    Wigler, Ronald; Koren, Tal; Tsesis, Igor

    2015-11-01

    To compare the cleaning effectiveness and shaping ability of SafeSider, ProTaper Universal and Lightspeed rotary instruments during the preparation of curved root canals in extracted human teeth. A total of 63 roots with curved root canals were divided into three groups. Canals were prepared using SafeSider, ProTaper Universal or Lightspeed LSX. Using pre- and post-instrumentation radiographs, straightening of the canal curvatures and loss of working length were determined with a computer image analysis program. The amounts of debris at the apical 5 mm were quantified on the basis of a numerical evaluation scale. The data were analyzed statistically using the two-way analysis of variance (ANOVA). There was significantly more transportation among the Lightspeed LSX group compared to the SafeSider and ProTaper Universal groups only at the 4 mm level (p < 0.05). The ProTaper Universal instruments performed significantly faster than other groups. No significant differences were observed between the three engine-driven instruments with regards to debris removal. SafeSider, ProTaper Universal and Lightspeed LSX rotary instruments maintained the original canal curvature well at the apical 3 mm and were safe to use. No difference was found in cleaning efficacy and none rendered the apical part of the canal free of debris. SafeSider, ProTaper Universal and Lightspeed LSX rotary instruments are safe to use in curved root canals.

  20. An approach to optimization of low-power Stirling cryocoolers

    NASA Technical Reports Server (NTRS)

    Sullivan, D. B.; Radebaugh, R.; Daney, D. E.; Zimmerman, J. E.

    1983-01-01

    A method for optimizing the design (shape of the displacer) of low power Stirling cryocoolers relative to the power required to operate the systems is described. A variational calculation which includes static conduction, shuttle and radiation losses, as well as regenerator inefficiency, was completed for coolers operating in the 300 K to 10 K range. While the calculations apply to tapered displacer machines, comparison of the results with stepped displacer cryocoolers indicates reasonable agreement.

  1. Approach to optimization of low-power Stirling cryocoolers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, D.B.; Radebaugh, R.; Daney, D.E.

    1983-12-01

    A method for optimizing the design (shape of the displacer) of low power Stirling cryocoolers relative to the power required to operate the systems is described. A variational calculation which includes static conduction, shuttle and radiation losses, as well as regenerator inefficiency, was completed for coolers operating in the 300 K to 10 K range. While the calculations apply to tapered displacer machines, comparison of the results with stepped displacer cryocoolers indicates reasonable agreement.

  2. Improvement of finite element meshes - Heat transfer in an infinite cylinder

    NASA Technical Reports Server (NTRS)

    Kittur, Madan G.; Huston, Ronald L.; Oswald, Fred B.

    1989-01-01

    An extension of a structural finite element mesh improvement technique to heat conduction analysis is presented. The mesh improvement concept was originally presented by Prager in studying tapered, axially loaded bars. It was further shown that an improved mesh can be obtained by minimizing the trace of the stiffnes matrix. These procedures are extended and applied to the analysis of heat conduction in an infinitely long hollow circular cylinder.

  3. FFT-local gravimetric geoid computation

    NASA Technical Reports Server (NTRS)

    Nagy, Dezso; Fury, Rudolf J.

    1989-01-01

    Model computations show that changes of sampling interval introduce only 0.3 cm changes, whereas zero padding provides an improvement of more than 5 cm in the fast Fourier transformation (FFT) generated geoid. For the Global Positioning System (GPS) survey of Franklin County, Ohio, the parameters selected as a result of model computations, allow large reduction in local data requirements while still retaining the cm accuracy when tapering and padding is applied. The results are shown in tables.

  4. Improvement in finite element meshes: Heat transfer in an infinite cylinder

    NASA Technical Reports Server (NTRS)

    Kittur, Madan G.; Huston, Ronald L.; Oswald, Fred B.

    1988-01-01

    An extension of a structural finite element mesh improvement technique to heat conduction analysis is presented. The mesh improvement concept was originally presented by Prager in studying tapered, axially loaded bars. It was further shown that an improved mesh can be obtained by minimizing the trace of the stiffness matrix. These procedures are extended and applied to the analysis of heat conduction in an infinitely long hollow circular cylinder.

  5. Validation of Volume and Taper Equations For Loblolly Shortleaf and Slash Pine

    Treesearch

    Allan E. Tiarks; V. Clark Baldwin

    1999-01-01

    Inside-bark diameter measurements at 6.64 intervals of 137 loblolly, 52 shortleaf, and 64 slash pines were used to calculate the actual volume and taper of each species for comparison with volumes and tapers predicted from published equations. The loblolly pine were cut in Texas (TX) and Louisiana (LA) while the shortleaf was sampled only in TX. The slash pine were...

  6. Compatible taper and volume equations for young longleaf pine plantations in southwest Georgia

    Treesearch

    Lichun Jiang; John R. Brooks; Alexander Clark

    2010-01-01

    Inside and outside bark taper equations as well as compatible cubic foot volume equations were developed from felled tree data selected from young longleaf pine plantations that are part of an existing growth and yield study located in the Flint River drainage of southwest Georgia. A Max-Burkhart taper model was selected as the basic model form due to the accuracy...

  7. Microdroplet-etched highly birefringent low-loss fiber tapers.

    PubMed

    Mikkelsen, Jared C; Poon, Joyce K S

    2012-07-01

    We use hydrofluoric acid microdroplets to directly etch highly birefringent biconical fiber tapers from standard single-mode fibers. The fiber tapers have micrometer-sized cross sections, which are controlled by the etching condition. The characteristic teardrop cross section leads to a high group birefringence of B(G)≈0.017 and insertion losses <0.7 dB over waist lengths of about 2.1 mm.

  8. Comparison of estimates of hardwood bole volume using importance sampling, the centroid method, and some taper equations

    Treesearch

    Harry V., Jr. Wiant; Michael L. Spangler; John E. Baumgras

    2002-01-01

    Various taper systems and the centroid method were compared to unbiased volume estimates made by importance sampling for 720 hardwood trees selected throughout the state of West Virginia. Only the centroid method consistently gave volumes estimates that did not differ significantly from those made by importance sampling, although some taper equations did well for most...

  9. Tapered holey fibers for spot-size and numerical-aperture conversion.

    PubMed

    Town, G E; Lizier, J T

    2001-07-15

    Adiabatically tapered holey fibers are shown to be potentially useful for guided-wave spot-size and numerical-aperture conversion. Conditions for adiabaticity and design guidelines are provided in terms of the effective-index model. We also present finite-difference time-domain calculations of downtapered holey fiber, showing that large spot-size conversion factors are obtainable with minimal loss by use of short, optimally shaped tapers.

  10. Effect of three different rotary instrumentation systems on postinstrumentation pain: A randomized clinical trial

    PubMed Central

    Subbiya, Arunajatesan; Cherkas, Pavel S.; Vivekanandhan, Paramasivam; Geethapriya, Nagarajan; Malarvizhi, Dhakshinamoorthy; Mitthra, Suresh

    2017-01-01

    Background: Endodontic instrumentation is liable to cause some postinstrumentation pain (PIP). Rotary endodontic instruments differ in their design, metallurgy, surface treatment, etc. Aim: This randomized clinical trial aimed to assess the incidence of PIP after root canal instrumentation with three different rotary endodontic systems which differ in their design, namely, ProTaper, Mtwo, and K3. Materials and Methods: A total of 150 patients between the ages of 25 and 50 were chosen for the study. Teeth with asymptomatic irreversible pulpitis due to carious exposure were selected. The patients received local anesthesia by inferior alveolar nerve block. After preparing the access cavity, root canal instrumentation was done with one of the three instruments (n = 50) and closed dressing was given. PIP was assessed every 12 h for 5 days, and tenderness to percussion was analyzed at the end of 1, 3, and 7 days. Statistical Analysis: Mann–Whitney U-test to determine significant differences at P < 0.01. Results: The PIP and tenderness were less in Mtwo group when compared to ProTaper and K3 groups up to 84 h and 72 h respectively and statistically significant (P < 0.05). There was no statistically significant difference between ProTaper and K3 both in PIP and tenderness. Conclusion: Rotary endodontic instrumentation causes some degree of PIP and tenderness to percussion. Among the instruments used, Mtwo causes less PIP and tenderness when compared to ProTaper and K3, and there was no difference between ProTaper and K3. Clinical Relevance: PIP is highly subjective and may vary among different subjects. The apical (3 mm) taper of ProTaper was 0.08 followed by a smaller taper, whereas, the other two files were of a constant 0.06 taper, which means there could have been a greater apical extrusion and therefore more PIP. Despite, the mean of the age was similar, there could have been a difference in the size of the canal and therefore a difference in apical extrusion and PIP. PMID:29430103

  11. Mental health, fatigue and function are associated with increased risk of disease flare following TNF inhibitor tapering in patients with rheumatoid arthritis: an exploratory analysis of data from the Optimizing TNF Tapering in RA (OPTTIRA) trial.

    PubMed

    Bechman, Katie; Sin, Fang En; Ibrahim, Fowzia; Norton, Sam; Matcham, Faith; Scott, David Lloyd; Cope, Andrew; Galloway, James

    2018-01-01

    Tapering of anti-tumour necrosis factor (TNF) therapy appears feasible, safe and effective in selected patients with rheumatoid arthritis (RA). Depression is highly prevalent in RA and may impact on flare incidence through various mechanisms. This study aims to investigate if psychological states predict flare in patients' dose tapering their anti-TNF therapy. This study is a post-hoc analysis of the Optimizing TNF Tapering in RA trial, a multicentre, randomised, open-label study investigating anti-TNF tapering in RA patients with sustained low disease activity. Patient-reported outcomes (Health Assessment Questionnaire, EuroQol 5-dimension scale, Functional Assessment of Chronic Illness Therapy fatigue scale (FACIT-F), 36-Item Short Form Survey (SF-36)) were collected at baseline. The primary outcome was flare, defined as an increase in 28-joint count Disease Activity Score (DAS28) ≥0.6 and ≥1 swollen joint. Discrete-time survival models were used to identify patient-reported outcomes that predict flare. Ninety-seven patients were randomised to taper their anti-TNF dose by either 33% or 66%. Forty-one patients flared. Higher baseline DAS28 score was associated with flare (adjusted HR 1.96 (95% CI 1.18 to 3.24), p=0.01). Disability (SF-36 physical component score), fatigue (FACIT-F) and mental health (SF-36 mental health subscale (MH)) predicted flare in unadjusted models. In multivariate analyses, only SF-36 MH remained a statistically significant predictor of flare (adjusted HR per 10 units 0.74 (95% CI 0.60 to 0.93), p=0.01). Baseline DAS28 and mental health status are independently associated with flare in patients who taper their anti-TNF therapy. Fatigue and function also associate with flare but the effect disappears when adjusting for confounders. Given these findings, mental health and functional status should be considered in anti-TNF tapering decisions in order to optimise the likelihood of success. EudraCT Number: 2010-020738-24; ISRCTN: 28955701; Post-results.

  12. Mental health, fatigue and function are associated with increased risk of disease flare following TNF inhibitor tapering in patients with rheumatoid arthritis: an exploratory analysis of data from the Optimizing TNF Tapering in RA (OPTTIRA) trial

    PubMed Central

    Bechman, Katie; Sin, Fang En; Ibrahim, Fowzia; Norton, Sam; Matcham, Faith; Scott, David Lloyd; Cope, Andrew; Galloway, James

    2018-01-01

    Background Tapering of anti-tumour necrosis factor (TNF) therapy appears feasible, safe and effective in selected patients with rheumatoid arthritis (RA). Depression is highly prevalent in RA and may impact on flare incidence through various mechanisms. This study aims to investigate if psychological states predict flare in patients’ dose tapering their anti-TNF therapy. Methods This study is a post-hoc analysis of the Optimizing TNF Tapering in RA trial, a multicentre, randomised, open-label study investigating anti-TNF tapering in RA patients with sustained low disease activity. Patient-reported outcomes (Health Assessment Questionnaire, EuroQol 5-dimension scale, Functional Assessment of Chronic Illness Therapy fatigue scale (FACIT-F), 36-Item Short Form Survey (SF-36)) were collected at baseline. The primary outcome was flare, defined as an increase in 28-joint count Disease Activity Score (DAS28) ≥0.6 and ≥1 swollen joint. Discrete-time survival models were used to identify patient-reported outcomes that predict flare. Results Ninety-seven patients were randomised to taper their anti-TNF dose by either 33% or 66%. Forty-one patients flared. Higher baseline DAS28 score was associated with flare (adjusted HR 1.96 (95% CI 1.18 to 3.24), p=0.01). Disability (SF-36 physical component score), fatigue (FACIT-F) and mental health (SF-36 mental health subscale (MH)) predicted flare in unadjusted models. In multivariate analyses, only SF-36 MH remained a statistically significant predictor of flare (adjusted HR per 10 units 0.74 (95% CI 0.60 to 0.93), p=0.01). Conclusions Baseline DAS28 and mental health status are independently associated with flare in patients who taper their anti-TNF therapy. Fatigue and function also associate with flare but the effect disappears when adjusting for confounders. Given these findings, mental health and functional status should be considered in anti-TNF tapering decisions in order to optimise the likelihood of success. Trial registration numbers EudraCT Number: 2010-020738-24; ISRCTN: 28955701; Post-results. PMID:29862047

  13. Resurgence of catatonia following tapering or stoppage of lorazepam - A case series and implications.

    PubMed

    Ali, Syed Farooq; Gowda, Guru S; Jaisoorya, T S; Math, Suresh Bada

    2017-08-01

    The resurgence of catatonia following tapering of lorazepam is a common clinical phenomenon. However, there is limited evidence on the relationship between tapering method of lorazepam and resurgence of catatonic state. We report seven (0.6%) such patients who were found to have resurgence of catatonia. The mean age is 35.7 years; five of them had schizophrenia and other psychotic spectrum disorders. Five of them had resurgence within one week of stoppage, and three of them had multiple resurgences and required maintenance treatment with lorazepam. So gradual tapering and maintenance treatment with lorazepam might be effective in preventing resurgence of catatonia. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Octave-spanning spectrum generation in tapered silica photonic crystal fiber by Yb:fiber ring laser above 500 MHz.

    PubMed

    Jiang, Tongxiao; Wang, Guizhong; Zhang, Wei; Li, Chen; Wang, Aimin; Zhang, Zhigang

    2013-02-15

    We report octave-spanning spectrum generated in a tapered silica photonic crystal fiber by a mode-locked Yb:fiber ring laser at a repetition rate as high as 528 MHz. The output pulses from this laser were compressed to 62 fs. By controlling the hole expansion and core diameter, a silica PCF was tapered to 20 cm with an optimal d/Λ ratio of 0.6. Pulses with the energy of 280 pJ and the peak power of 4.5 kW were injected into the tapered fiber and the pulse spectrum was expanded from 500 to 1600 nm at the level of -30 dB.

  15. Principles and performance of tapered fiber lasers: from uniform to flared geometry.

    PubMed

    Kerttula, Juho; Filippov, Valery; Chamorovskii, Yuri; Ustimchik, Vasily; Golant, Konstantin; Okhotnikov, Oleg G

    2012-10-10

    We have studied the recently demonstrated concept of fiber lasers based on active tapered double-clad fiber (T-DCF) in copropagating and counterpropagating configurations, both theoretically and experimentally, and compared the performance to fiber lasers based on conventional cylindrical fibers in end-pumped configurations. Specific properties of T-DCFs were considered theoretically using a rate-equation model developed for tapered fibers, and a detailed comparative study was carried out experimentally. Furthermore, we have studied mode coupling effects in long adiabatic tapers due to coiling and local bending. The results allow us to conclude that, with proper fiber design, the T-DCF technology offers a high-potential alternative for bright, cost-effective fiber devices.

  16. The STEM Initiative: Constraints and Challenges

    ERIC Educational Resources Information Center

    Herschbach, Dennis R.

    2011-01-01

    There is considerable national interest in STEM initiatives, but yet there is little discussion concerning what STEM means in terms of a curriculum concept to be applied to school programming. This article focuses on STEM as a curriculum concept. First, STEM programming is discussed in terms of separate subjects, correlated and broad fields…

  17. High Performance Slab-on-Grade Foundation Insulation Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldberg, Louise F.; Mosiman, Garrett E.

    ?A more accurate assessment of SOG foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulationmore » at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated). The optimum insulation strategy was applied to single and multi-family residential buildings in climate zone 4 - 7. The highest site energy savings of 5% was realized for a single family home in Duluth, MN, and the lowest savings of 1.4 % for a 4-unit townhouse in Richmond, VA. SOG foundation insulation retrofit simple paybacks ranged from 18 to 47 years. There are other benefits of SOG foundation insulation resulting from the increase in the slab surface temperatures. These include increased occupant thermal comfort, and a decrease in slab surface condensation particularly around the slab perimeter.« less

  18. Building America Case Study: Optimized Slab-on-Grade Foundation Insulation Retrofits, Madison, Wisconsin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A more accurate assessment of SOG foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulationmore » at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated). The optimum insulation strategy was applied to single and multi-family residential buildings in climate zone 4 - 7. The highest site energy savings of 5% was realized for a single family home in Duluth, MN, and the lowest savings of 1.4 percent for a 4-unit townhouse in Richmond, VA. SOG foundation insulation retrofit simple paybacks ranged from 18 to 47 years. There are other benefits of SOG foundation insulation resulting from the increase in the slab surface temperatures. These include increased occupant thermal comfort, and a decrease in slab surface condensation particularly around the slab perimeter.« less

  19. Long-term survivorship of the Corail™ standard stem.

    PubMed

    Louboutin, L; Viste, A; Desmarchelier, R; Fessy, M-H

    2017-11-01

    The Corail™ stem, which was first introduced in 1986, has since been modified twice: first to make the neck thinner and then to change the location of the laser markings. The survival and complications of the first-generation straight, titanium, hydroxyapatite-coated stem are known; however, there is little specific information about the latest-generation stem. This led us to conduct a retrospective study to determine the: (1) long-term survival; (2) clinical and radiographic outcomes; (3) complications; and (4) risk factors for revision of the newest Corail™ stem. The newest Corail™ AMT (Articul/EZE™ Mini Taper) standard stem has comparable survival to prior models. This single-center, retrospective study included 133 patients (140 hips), who underwent primary total hip arthroplasty (THA), between January and December 2004, in which a Corail™ Standard stem was implanted using a posterolateral approach. Patients who underwent revision THA, THA due to femoral neck fracture or who received lateralized (offset) stems were excluded. The mean age at the time of THA was 69±13 years [35-92] in 85 men (61%) and 55 women (39%) who had a mean BMI of 27kg/m 2 ±11 [16-39]. At the latest follow-up, 32 patients (32 hips) had died and 8 patients (8 hips) had less than 3 years' follow-up, thus were not included in the clinical evaluation. The Merle d'Aubigné (PMA) score was collected. The stem's survivorship was calculated using the Kaplan-Meier method with revision for aseptic loosening and revision or implant removal for any reason as the end-points. The Cox model was used to analyze risk factors for revision. The mean follow-up was 10±3 years [3-12]. The PMA score was 12±2.6 [5-17] preoperatively and 16±2.7 [7-18] at the last follow-up (P<0.00001). Eighteen complications (12.8%) were recorded at the last follow-up. There were 15 early complications: 6 dislocations, 5 calcar fractures (4 treated by wire cerclage and 1 by stem change plus wire cerclage), 2 greater trochanter fractures (treated non-surgically) and 2 cases of sciatic nerve palsy. There were 3 late complications: 2 cases of iliopsoas irritation and 1 ceramic insert fracture. Stem survival for surgical revision due to aseptic loosening was 98% (95% CI: [0.96-1]). At 12 years, 95% of stems had not been revised or removed (95% CI: [0.92-0.99]). Being less than 58 years of age at the time of surgery was the only risk factor significantly associated with stem revision for any reason (P=0.04). Survival of the Corail™ Standard stem is similar to that of previous generation stems. The changes made in this stem solved the neck failure problem and did not induce new complications. Level IV (retrospective study). Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  20. Centering Ability of ProTaper Next and WaveOne Classic in J-Shape Simulated Root Canals

    PubMed Central

    Dioguardi, Mario; Cocco, Armando; Giuliani, Michele; Fabiani, Cristiano; D'Alessandro, Alfonso; Ciavarella, Domenico

    2016-01-01

    Introduction. The aim of this study was to evaluate and compare the shaping and centering ability of ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland) and WaveOne Classic systems (Dentsply Maillefer) in simulated root canals. Methods. Forty J-shaped canals in resin blocks were assigned to two groups (n = 20 for each group). Photographic method was used to record pre- and postinstrumentation images. After superimposition, centering and shaping ability were recorded at 9 different levels from the apex using the software Autocad 2013 (Autodesk Inc., San Rafael, USA). Results. Shaping procedures with ProTaper Next resulted in a lower amount of resin removed at each reference point level. In addition, the pattern of centering ability improved after the use of ProTaper Next in 8 of 9 measurement points. Conclusions. Within the limitations of this study, shaping procedures with ProTaper Next instruments demonstrated a lower amount of resin removed and a better centering ability than WaveOne Classic system. PMID:28054031

  1. Centering Ability of ProTaper Next and WaveOne Classic in J-Shape Simulated Root Canals.

    PubMed

    Troiano, Giuseppe; Dioguardi, Mario; Cocco, Armando; Giuliani, Michele; Fabiani, Cristiano; D'Alessandro, Alfonso; Ciavarella, Domenico; Lo Muzio, Lorenzo

    Introduction . The aim of this study was to evaluate and compare the shaping and centering ability of ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland) and WaveOne Classic systems (Dentsply Maillefer) in simulated root canals. Methods . Forty J-shaped canals in resin blocks were assigned to two groups ( n = 20 for each group). Photographic method was used to record pre- and postinstrumentation images. After superimposition, centering and shaping ability were recorded at 9 different levels from the apex using the software Autocad 2013 (Autodesk Inc., San Rafael, USA). Results . Shaping procedures with ProTaper Next resulted in a lower amount of resin removed at each reference point level. In addition, the pattern of centering ability improved after the use of ProTaper Next in 8 of 9 measurement points. Conclusions . Within the limitations of this study, shaping procedures with ProTaper Next instruments demonstrated a lower amount of resin removed and a better centering ability than WaveOne Classic system.

  2. Comparative evaluation of dentinal crack formation after root canal preparation using ProTaper Next, OneShape, and Hyflex EDM

    PubMed Central

    Das, Sanjib; Pradhan, Prasanti Kumari; Lata, S.; Sinha, Sachidananda Prasad

    2018-01-01

    Introduction: The purpose of this study was to compare the incidence of dentinal crack formation after root canal preparation using ProTaper Next, OneShape, and Hyflex electrodischarge machining (HEDM). Materials and Methods: A total of 75 extracted mandibular premolars were selected. The root canals were instrumented using ProTaper Next, OneShape, and HEDM rotary files. All roots were horizontally sectioned at 3, 6, and 9 mm from apex with slow-speed saw under water cooling. The sections were observed under a stereomicroscope at ×25 to determine the absence or presence of crack. Data were analyzed using post hoc test and one-way ANOVA. Results: ProTaper Next and HEDM produced significantly less cracks than OneShape. Conclusion: Within the limitation of this in vitro study, it can be concluded that nickel–titanium instruments may cause cracks on the root surface. ProTaper Next and HEDM tend to produce less number of cracks as compared to OneShape. PMID:29674816

  3. Dynamic illumination of spatially restricted or large brain volumes via a single tapered optical fiber

    PubMed Central

    Pisanello, Marco; Oldenburg, Ian A.; Sileo, Leonardo; Markowitz, Jeffrey E.; Peterson, Ralph E.; Della Patria, Andrea; Haynes, Trevor M.; Emara, Mohamed S.; Spagnolo, Barbara; Datta, Sandeep Robert; De Vittorio, Massimo; Sabatini, Bernardo L.

    2017-01-01

    Optogenetics promises spatiotemporal precise control of neural processes using light. However, the spatial extent of illumination within the brain is difficult to control and cannot be adjusted using standard fiber optics. We demonstrate that optical fibers with tapered tips can be used to illuminate either spatially restricted or large brain volumes. Remotely adjusting the light input angle to the fiber varies the light-emitting portion of the taper over several millimeters without movement of the implant. We use this mode to activate dorsal versus ventral striatum of individual mice and reveal different effects of each manipulation on motor behavior. Conversely, injecting light over the full numerical aperture of the fiber results in light emission from the entire taper surface, achieving broader and more efficient optogenetic activation of neurons when compared to the standard flat-faced fiber stimulation. Thus, tapered fibers permit focal or broad illumination that can be precisely and dynamically matched to experimental needs. PMID:28628101

  4. Changes of propagation light in optical fiber submicron wires

    NASA Astrophysics Data System (ADS)

    Stasiewicz, K. A.; Łukowski, A.; Jaroszewicz, L. R.

    2013-05-01

    At the moment technology allows to miniaturize measurement system to several micrometers. Application of an optical fiber taper in such system needs to manufacture a new one with diameters below single micrometers which is very difficult and expensive. Another way to obtain this level of diameters is the process of tapering from the existing fibers. In the paper, experimental results of propagation light from a supercontinnum sources of the wavelength generates the wavelength of 350-2000 nm, in different optical fiber submicron wires made from tapers manufactured from single mode fibers are presented. Biconical optical fibers' tapers were manufactured in low pressure gas burner technique. There are presented spectral characteristics of a propagated beam. For the test, there was manufactured an optical fiber submicron wires with a different length of waist region with a diameter near one micrometer. We put to the test a taper made from a standard telecommunication fiber SMF-28 with a cutoff wavelength equal to 1260.

  5. Dynamic illumination of spatially restricted or large brain volumes via a single tapered optical fiber.

    PubMed

    Pisanello, Ferruccio; Mandelbaum, Gil; Pisanello, Marco; Oldenburg, Ian A; Sileo, Leonardo; Markowitz, Jeffrey E; Peterson, Ralph E; Della Patria, Andrea; Haynes, Trevor M; Emara, Mohamed S; Spagnolo, Barbara; Datta, Sandeep Robert; De Vittorio, Massimo; Sabatini, Bernardo L

    2017-08-01

    Optogenetics promises precise spatiotemporal control of neural processes using light. However, the spatial extent of illumination within the brain is difficult to control and cannot be adjusted using standard fiber optics. We demonstrate that optical fibers with tapered tips can be used to illuminate either spatially restricted or large brain volumes. Remotely adjusting the light input angle to the fiber varies the light-emitting portion of the taper over several millimeters without movement of the implant. We use this mode to activate dorsal versus ventral striatum of individual mice and reveal different effects of each manipulation on motor behavior. Conversely, injecting light over the full numerical aperture of the fiber results in light emission from the entire taper surface, achieving broader and more efficient optogenetic activation of neurons, compared to standard flat-faced fiber stimulation. Thus, tapered fibers permit focal or broad illumination that can be precisely and dynamically matched to experimental needs.

  6. Asymmetrical dual tapered fiber Mach-Zehnder interferometer for fiber-optic directional tilt sensor.

    PubMed

    Lee, Cheng-Ling; Shih, Wen-Cheng; Hsu, Jui-Ming; Horng, Jing-Shyang

    2014-10-06

    This work proposes a novel, highly sensitive and directional fiber tilt sensor that is based on an asymmetrical dual tapered fiber Mach-Zehnder interferometer (ADTFMZI). The fiber-optic tilt sensor consists of two abrupt tapers with different tapered waists into which are incorporated a set of iron spheres to generate an asymmetrical strain in the ADTFMZI that is correlated with the tilt angle and the direction of inclination. Owing to the asymmetrical structure of the dual tapers, the proposed sensor can detect the non-horizontal/horizontal state of a structure and whether the test structure is tilted to clockwise or counterclockwise by measuring the spectral responses. Experimental results show that the spectral wavelengths are blue-shifted and red-shifted when the sensor tilts to clockwise (-θ) and counterclockwise ( + θ), respectively. Tilt angle sensitivities of about 335 pm/deg. and 125 pm/deg. are achieved in the -θ and + θ directions, respectively, when the proposed sensing scheme is utilized.

  7. Investigation of Tapered Roller Bearing Damage Detection Using Oil Debris Analysis

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Krieder, Gary; Fichter, Thomas

    2006-01-01

    A diagnostic tool was developed for detecting fatigue damage to tapered roller bearings. Tapered roller bearings are used in helicopter transmissions and have potential for use in high bypass advanced gas turbine aircraft engines. This diagnostic tool was developed and evaluated experimentally by collecting oil debris data from failure progression tests performed by The Timken Company in their Tapered Roller Bearing Health Monitoring Test Rig. Failure progression tests were performed under simulated engine load conditions. Tests were performed on one healthy bearing and three predamaged bearings. During each test, data from an on-line, in-line, inductance type oil debris sensor was monitored and recorded for the occurrence of debris generated during failure of the bearing. The bearing was removed periodically for inspection throughout the failure progression tests. Results indicate the accumulated oil debris mass is a good predictor of damage on tapered roller bearings. The use of a fuzzy logic model to enable an easily interpreted diagnostic metric was proposed and demonstrated.

  8. Coherent emission from a bunched electron beam: superradiance and stimulated-superradiance in a uniform and tapered wiggler FEL

    NASA Astrophysics Data System (ADS)

    Gover, A.; Ianconescu, R.; Friedman, A.; Emma, C.; Musumeci, P.

    2017-09-01

    We outline fundamental coherent radiation processes from a charge particles beam: Spontaneous Superradiance (SR), Stimulated Superradiance (ST-SR), and in the context of undulator radiation: Tapering-Enhanced Superradiance (TES) and Tapering-Enhanced Stimulated Superradiance Amplification (TESSA). Both single bunch and periodic bunching (in phasor and spectral Fourier frequency formulations) are considered in a model of radiation mode expansion.

  9. Near-field fluorescence thermometry using highly efficient triple-tapered near-field optical fiber probe.

    PubMed

    Fujii, T; Taguchi, Y; Saiki, T; Nagasaka, Y

    2012-12-01

    A novel local temperature measurement method using fluorescence near-field optics thermal nanoscopy (Fluor-NOTN) has been developed. Fluor-NOTN enables nanoscale temperature measurement in situ by detecting the temperature-dependent fluorescence lifetime of CdSe quantum dots (QDs). In this paper, we report a novel triple-tapered near-field optical fiber probe that can increase the temperature measurement sensitivity of Fluor-NOTN. The performance of the proposed probe was numerically evaluated by the finite difference time domain method. Due to improvements in both the throughput and collection efficiency of near-field light, the sensitivity of the proposed probe was 1.9 times greater than that of typical double-tapered probe. The proposed shape of the triple-tapered core was successfully fabricated utilizing a geometrical model. The detected signal intensity of dried layers of QDs was greater by more than two orders than that of auto-fluorescence from the fiber core. In addition, the near-field fluorescence lifetime of the QDs and its temperature dependence were successfully measured by the fabricated triple-tapered near-field optical fiber probe. These measurement results verified the capability of the proposed triple-tapered near-field optical fiber probe to improve the collection efficiency of near-field fluorescence.

  10. Laboratory comparison of the mechanical properties of TRUShape with several nickel-titanium rotary instruments.

    PubMed

    Elnaghy, A M; Elsaka, S E

    2017-08-01

    To assess and compare the mechanical properties of TRUShape (TRS) with several nickel-titanium rotary instruments. Cyclic fatigue, torsional resistance, flexibility and surface microhardness of TRS (size 25, 0.06v taper), ProTaper Next X2 (PTN X2, size 25, 0.06 taper), ProTaper Gold (PTG F2; size 25, 0.08 taper) and ProTaper Universal (PTU F2; size 25, 0.08 taper) instruments were evaluated. The topographical structures of the fracture surfaces of instruments were assessed using a scanning electron microscope. The cyclic fatigue resistance, torsional resistance and microhardness data were analysed using one-way analysis of variance (anova) and Tukey's post hoc tests. The fragment length and bending resistance data were analysed statistically with the Kruskal-Wallis H-test and Mann-Whitney U-tests. The statistical significance level was set at P < 0.05. PTN and PTG instruments revealed significantly higher resistance to cyclic fatigue than TRS and PTU instruments (P < 0.001). PTN instruments revealed significantly higher torsional resistance compared with the other instruments (P < 0.001). PTG instrument had significantly higher flexibility than the other tested brands (P < 0.05). However, for microhardness, the PTU had significantly higher surface microhardness values compared with other tested brands (P < 0.05). TRS instruments had lower resistance to cyclic fatigue and lower flexibility compared with PTG and PTN instruments. TRS, PTG and PTU instruments had lower resistance to torsional stress than PTN instruments. TRS and PTG instruments had comparable surface microhardness. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  11. Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary files.

    PubMed

    Elnaghy, A M

    2014-11-01

    To compare the cyclic fatigue resistance of ProTaper Next files (PTN; Dentsply Maillefer, Ballaigues, Switzerland) with Twisted Files (TF; SybronEndo, Orange, CA, USA), HyFlex CM (HF; ColténeEndo/Whaledent, Inc, Cuyahoga Falls, OH, USA) and ProTaper Universal (PT; Dentsply Maillefer). Size 25, .06 taper for PTN X2, TF, HF and PT F1 size 20, .07 taper were rotated in simulated canals until failure, and the number of cycles to failure (NCF) was recorded to evaluate their cyclic fatigue resistance. A scanning electron microscope was used to characterize the topographic features of the fracture surfaces of broken files. The data of the NCF and fragment length values were analysed statistically using one-way analysis of variance and Tukey post hoc tests. Statistical significance level was set at P < 0.05. Twisted Files had a significantly higher resistance to cyclic fatigue than the other instruments (P < 0.05). No significant difference was found in NCF between PTN and HF (P > 0.05); however, there was a significant difference (P < 0.05) of both these systems with PT, which exhibited the lowest mean NCF. The ranking in the NCF values was: TF > PTN > HF > PT. The fracture cross-sections of all brands revealed similar fractographic features, including crack origins, fatigue zone and an overload fast fracture zone. The new ProTaper Next had greater resistance to cyclic fatigue compared with ProTaper and HyFlex CM but not the Twisted Files. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  12. Testing and Life Prediction for Composite Rotor Hub Flexbeams

    NASA Technical Reports Server (NTRS)

    Murri, Gretchen B.

    2004-01-01

    A summary of several studies of delamination in tapered composite laminates with internal ply-drops is presented. Initial studies used 2D FE models to calculate interlaminar stresses at the ply-ending locations in linear tapered laminates under tension loading. Strain energy release rates for delamination in these laminates indicated that delamination would likely start at the juncture of the tapered and thin regions and grow unstably in both directions. Tests of glass/epoxy and graphite/epoxy linear tapered laminates under axial tension delaminated as predicted. Nonlinear tapered specimens were cut from a full-size helicopter rotor hub and were tested under combined constant axial tension and cyclic transverse bending loading to simulate the loading experienced by a rotorhub flexbeam in flight. For all the tested specimens, delamination began at the tip of the outermost dropped ply group and grew first toward the tapered region. A 2D FE model was created that duplicated the test flexbeam layup, geometry, and loading. Surface strains calculated by the model agreed very closely with the measured surface strains in the specimens. The delamination patterns observed in the tests were simulated in the model by releasing pairs of MPCs along those interfaces. Strain energy release rates associated with the delamination growth were calculated for several configurations and using two different FE analysis codes. Calculations from the codes agreed very closely. The strain energy release rate results were used with material characterization data to predict fatigue delamination onset lives for nonlinear tapered flexbeams with two different ply-dropping schemes. The predicted curves agreed well with the test data for each case studied.

  13. Volatility and change in chronic pain severity predict outcomes of treatment for prescription opioid addiction.

    PubMed

    Worley, Matthew J; Heinzerling, Keith G; Shoptaw, Steven; Ling, Walter

    2017-07-01

    Buprenorphine-naloxone (BUP-NLX) can be used to manage prescription opioid addiction among persons with chronic pain, but post-treatment relapse is common and difficult to predict. This study estimated whether changes in pain over time and pain volatility during BUP-NLX maintenance would predict opioid use during the taper BUP-NLX taper. Secondary analysis of a multi-site clinical trial for prescription opioid addiction, using data obtained during a 12-week BUP-NLX stabilization and 4-week BUP-NLX taper. Community clinics affiliated with a national clinical trials network in 10 US cities. Subjects with chronic pain who entered the BUP-NLX taper phase (n = 125) with enrollment occurring from June 2006 to July 2009 (52% male, 88% Caucasian, 31% married). Outcomes were weekly biologically verified and self-reported opioid use from the 4-week taper phase. Predictors were estimates of baseline severity, rate of change and volatility in pain from weekly self-reports during the 12-week maintenance phase. Controlling for baseline pain and treatment condition, increased pain [odds ratio (OR) = 2.38, P = 0.02] and greater pain volatility (OR = 2.43, P = 0.04) predicted greater odds of positive opioid urine screen during BUP-NLX taper. Increased pain (IRR = 1.40, P = 0.04) and greater pain volatility [incidence-rate ratio (IRR) = 1.66, P = 0.009] also predicted greater frequency of self-reported opioid use. Adults with chronic pain receiving out-patient treatment with buprenorphine-naloxone (BUP-NLX) for prescription opioid addiction have an elevated risk for opioid use when tapering off maintenance treatment. Those with relative persistence in pain over time and greater volatility in pain during treatment are less likely to sustain abstinence during BUP-NLX taper. © 2017 Society for the Study of Addiction.

  14. Improved vibration sensor based on a biconical tapered singlemode fiber, using in-fiber Mach-Zehnder interferometer

    NASA Astrophysics Data System (ADS)

    Wonko, R.; Moś, J. E.; Stasiewicz, K. A.; Jaroszewicz, L. R.

    2017-05-01

    Optical fiber vibration sensors are an appropriate alternative for piezoelectric devices, which are electromagnetic sensitive to the external conditions. Most of the vibration sensors demonstrated in previous publications resist to different interferometers or Bragg's gratings. Such sensors require a long time of stabilization of an optical signal, because they are vulnerable to undesirable disturbance. In majority, time response of an optical sensor should be instantaneous, therefore we have proposed an in- line vibration sensing passive element based on a tapered fiber. Micrometer sized optical fiber tapers are attractive for many optical areas due to changes process of boundary conditions. Such phenomena allow for a sensitive detection of the modulation phase. Our experiment shows that a singlemode, adiabatic tapered fiber enables detecting an acoustic vibration. In this study, we report on Mach- Zehnder (MZ) interferometer as a vibration sensor which was composed of two 50/50 couplers at 1550 nm. In the reference arm we used a 4 meter singlemode optical fiber (SMF28), while in the arm under test we placed tapered optical fibers attached to a metal plate, put directly on speaker. Researches carried out on different tapered fibers which diameter of a taper waist was in the range from 5 μm to 25 μm, and each taper was characterized by optical losses less than 0,5 dB. The measured phase changes were over a frequency from 100 Hz to 1 kHz and an amplitude in the range from 100 mVpp to 1 Vpp. Although on account of a limited space we have showed only the results for 100 Hz. Nevertheless, experimental results show that this sensing system has a wide frequency response range from a few hertz to one of kilohertz, however for some conditions, a standard optical fiber showed better result.

  15. In Vitro Comparison of Cyclic Fatigue Resistance of ProTaper Next, HyFlex CM, OneShape, and ProTaper Universal Instruments in a Canal with a Double Curvature.

    PubMed

    Topçuoğlu, Hüseyin Sinan; Topçuoğlu, Gamze; Akti, Ahmet; Düzgün, Salih

    2016-06-01

    The aim of this study was to compare the resistance to cyclic fatigue of ProTaper Next X2 (PTN X2; size 25, 0.06 taper), Hyflex CM (HCM; size 25, 0.06 taper), OneShape (OS; size 25, 0.06 taper), and ProTaper Universal F2 (PTU F2; size 25, 0.08 taper) nickel-titanium files in an artificial root canal with a double (S-shaped) curvature. A total of 160 new PTN X2, OS, HCM, and PTU F2 files were tested in an artificial stainless steel canal with a double curvature. Forty files from each system were rotated until fracture to calculate the number of cycles to failure. The length of each fractured fragment was recorded. Data were analyzed by using one-way analysis of variance and Tukey post hoc tests. The resistance to cyclic fatigue of the PTN X2 and HCM instruments was significantly greater than the OS and PTU F2 instruments in the apical curvature (P < .05). There was no statistical difference in the cyclic fatigue resistance of the PTN X2 and HCM instruments in the apical curvature (P > .05). In addition, there was no statistical difference between the OS and PTU F2 instruments in the apical curvature (P > .05). PTN X2, OS, HCM, and PTU F2 instruments showed similar cyclic fatigue resistance values in the coronal curvature (P > .05). This study showed that PTN X2 and HCM instruments exhibit greater resistance to cyclic fatigue than OS and PTU F2 instruments in the apical curvature of an artificial canal with a double curvature. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. An initial experience with hip resurfacing versus cementless total hip arthroplasty.

    PubMed

    Arndt, Justin Michael; Wera, Glenn D; Goldberg, Victor M

    2013-07-01

    Hip resurfacing is an alternative to total hip arthroplasty. We aimed to compare an experienced hip surgeon's initial clinical results of hip resurfacing with a new cementless total hip arthroplasty (THA). The first 55 consecutive hip resurfacing arthroplasties were compared to 100 consecutive cementless THAs using a cylindrical tapered femoral stem. The learning curve between the two procedures was compared utilizing the incidence of reoperation, complications, Harris Hip Scores (HHS), and implant survivorship. The reoperation rate was significantly higher (p = 0.019) for hip resurfacing (14.5%) versus THA (4%). The overall complication rate between the two groups was not significantly different (p = 0.398). Preoperative HHS were similar between the two groups (p = 0.2). The final mean HHS was similar in both the resurfacing and THA groups (96 vs. 98.3, respectively, p < 0.65). Kaplan-Meier survival analysis with an endpoint of reoperation suggests complications occurred earlier in the resurfacing group versus the THA group (log-rank test, p = 0.007). In comparison to our initial experience with a cementless THA stem, operative complications occur earlier and more often after hip resurfacing during the learning period. The clinical outcomes in both groups however are similar at 5 year follow-up.

  17. Approach to optimization of low-power Stirling cryocoolers. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, D.B.; Radebaugh, R.; Daney, D.E.

    1983-01-01

    The authors describe a method for optimizing the design (shape of the displacer) of low-power Stirling cryocoolers relative to the power required to operate the systems. A variational calculation which includes static conduction, shuttle, and radiation losses, as well as regenerator inefficiency, has been completed for coolers operating in the 300 K to 10 K range. While the calculations apply to tapered displacer machines, comparison of the results with stepped-displacer cryocoolers indicates reasonable agreement.

  18. Parametric weight evaluation of joined wings by structural optimization

    NASA Technical Reports Server (NTRS)

    Miura, Hirokazu; Shyu, Albert T.; Wolkovitch, Julian

    1988-01-01

    Joined-wing aircraft employ tandem wings having positive and negative sweep and dihedral, arranged to form diamond shapes in both plan and front views. An optimization method was applied to study the effects of joined-wing geometry parameters on structural weight. The lightest wings were obtained by increasing dihedral and taper ratio, decreasing sweep and span, increasing fraction of airfoil chord occupied by structural box, and locating the joint inboard of the front wing tip.

  19. O-Ring-Testing Fixture

    NASA Technical Reports Server (NTRS)

    Turner, James E.; Mccluney, D. Scott

    1991-01-01

    Fixture tests O-rings for sealing ability under dynamic conditions after extended periods of compression. Hydraulic cylinder moves plug in housing. Taper of 15 degrees on plug and cavity of housing ensures that gap created between O-ring under test and wall of cavity. Secondary O-rings above and below test ring maintain pressure applied to test ring. Evaluates effects of variety of parameters, including temperature, pressure, rate of pressurization, rate and magnitude of radial gap movement, and pretest compression time.

  20. All-polymeric sensing platform based on packaged self-assembled bottle microresonator (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Bernini, Romeo; Grimaldi, Immacolata A.; Persichetti, Gianluca; Testa, Genni

    2017-02-01

    In recent years, microbottle resonators that support non-degenerate whispering gallery modes (WGMs), propagating by successive total internal reflections close to the resonator surface and all along its axis, have been widely investigated due to their potential applications in optical sensing, microlasers and nonlinear optics. To overcome some drawbacks of the standard silica microbottle resonators, we focused our attention on polymers such as SU-8 resist and NOA resins. A drop of polymeric material is dispensed onto a fiber stem, providing a mechanical support for the bottle resonator, and is photo-polymerized by an UV lamp. The interrogation system, usually constituted by a tapered silica fiber evanescently coupled with the microresonator, is substituted by a more stable planar waveguide realized in SU-8 by means of standard photolithography technique. Moreover, for guarantying the stability to surrounding disturbance of the coupling between the microbottle resonator and the planar waveguide, the fiber stem is glued to substrate. Two drilled holes in the substrate allow the rise of the glue at the ends of the fiber stem and the fixing of sensor on PMMA substrate. In the present work, we presented an integrated full polymeric platform with self-assembled bottle microresonators packaged in a stable structure. SU-8 and NOA based microbottles are realized and morphologically characterized. The low autofluorescence emission and long term stability make the NOA based bottles suitable to be employed in a great variety of conditions. Bulk sensing measurements are performed by using water:ethanol solutions and a bulk sensitivity of 120 nm/RIU is estimated.

  1. Accuracy of femoral templating in reproducing anatomical femoral offset in total hip replacement.

    PubMed

    Davies, H; Foote, J; Spencer, R F

    2007-01-01

    Restoration of hip biomechanics is a crucial component of successful total hip replacement. Preoperative templating is recommended to ensure that the size and orientation of implants is optimised. We studied how closely natural femoral offset could be reproduced using the manufacturers' templates for 10 femoral stems in common use in the UK. A series of 23 consecutive preoperative radiographs from patients who had undergone unilateral total hip replacement for unilateral osteoarthritis of the hip was employed. The change in offset between the templated position of the best-fitting template and the anatomical centre of the hip was measured. The templates were then ranked according to their ability to reproduce the normal anatomical offset. The most accurate was the CPS-Plus (Root Mean Square Error 2.0 mm) followed in rank order by: C stem (2.16), CPT (2.40), Exeter (3.23), Stanmore (3.28), Charnley (3.65), Corail (3.72), ABG II (4.30), Furlong HAC (5.08) and Furlong modular (7.14). A similar pattern of results was achieved when the standard error of variability of offset was analysed. We observed a wide variation in the ability of the femoral prosthesis templates to reproduce normal femoral offset. This variation was independent of the seniority of the observer. The templates of modern polished tapered stems with high modularity were best able to reproduce femoral offset. The current move towards digitisation of X-rays may offer manufacturers an opportunity to improve template designs in certain instances, and to develop appropriate computer software.

  2. Improved 20mm Plastic Rotating Bands

    DTIC Science & Technology

    1976-12-01

    Taper, and 13- Degree Aft Taper, In-Flight at 3, 786 Feet per Second Muzzle Velocity at Ambient Conditions ....... ... 46 I LIST OF ILLUSTRATIONS...at 3, 770 Feet per Second Muzzle Velocity at Ambient Conditions ......... ... 46 14 EG-D69-B-813/15 Series Projectile with 0.813-inch Band Diameter...15-Degree Fore and Aft Tapers, In- Flight at 3, 763 Feet per Second Muzzle Velocity at Ambient Conditions ..... ............... .... 47 15 EG-D69-B-813

  3. Optical pulse compression in dispersion decreasing photonic crystal fiber.

    PubMed

    Travers, J C; Stone, J M; Rulkov, A B; Cumberland, B A; George, A K; Popov, S V; Knight, J C; Taylor, J R

    2007-10-01

    Improvements to tapered photonic crystal fiber (PCF) fabrication have allowed us to make up to 50 m long PCF tapers with loss as low as 30 dB/km. We discuss the design constraints for tapered PCFs used for adiabatic soliton compression and demonstrate over 15 times compression of pulses from over 830 fs to 55 fs duration at a wavelength of 1.06 lm, an order of magnitude improvement over previous results.

  4. Design and Synthesis of Network-Forming Triblock Copolymers Using Tapered Block Interfaces

    PubMed Central

    Kuan, Wei-Fan; Roy, Raghunath; Rong, Lixia; Hsiao, Benjamin S.; Epps, Thomas H.

    2012-01-01

    We report a strategy for generating novel dual-tapered poly(isoprene-b-isoprene/styrene-b-styrene-b-styrene/methyl methacrylate-b-methyl methacrylate) [P(I-IS-S-SM-M)] triblock copolymers that combines anionic polymerization, atom transfer radical polymerization (ATRP), and Huisgen 1,3-dipolar cycloaddition click chemistry. The tapered interfaces between blocks were synthesized via a semi-batch feed using programmable syringe pumps. This strategy allows us to manipulate the transition region between copolymer blocks in triblock copolymers providing control over the interfacial interactions in our nanoscale phase-separated materials independent of molecular weight and block constituents. Additionally, we show the ability to retain a desirous and complex multiply-continuous network structure (alternating gyroid) in our dual-tapered triblock material. PMID:23066522

  5. Hole injection and electron overflow improvement in InGaN/GaN light-emitting diodes by a tapered AlGaN electron blocking layer.

    PubMed

    Lin, Bing-Chen; Chen, Kuo-Ju; Wang, Chao-Hsun; Chiu, Ching-Hsueh; Lan, Yu-Pin; Lin, Chien-Chung; Lee, Po-Tsung; Shih, Min-Hsiung; Kuo, Yen-Kuang; Kuo, Hao-Chung

    2014-01-13

    A tapered AlGaN electron blocking layer with step-graded aluminum composition is analyzed in nitride-based blue light-emitting diode (LED) numerically and experimentally. The energy band diagrams, electrostatic fields, carrier concentration, electron current density profiles, and hole transmitting probability are investigated. The simulation results demonstrated that such tapered structure can effectively enhance the hole injection efficiency as well as the electron confinement. Consequently, the LED with a tapered EBL grown by metal-organic chemical vapor deposition exhibits reduced efficiency droop behavior of 29% as compared with 44% for original LED, which reflects the improvement in hole injection and electron overflow in our design.

  6. Effect of the tapered end of a FRP plate on the interfacial stresses in a strengthened beam used in civil engineering applications

    NASA Astrophysics Data System (ADS)

    Mahi, B. E.; Benrahou, K. H.; Belakhdar, Kh.; Tounsi, A.; Bedia, E. A. Adda

    2014-09-01

    The interfacial stresses of a beam strengthened with a FRP plate, which is widely employed in the civil engineering for rehabilitation and retrofitting of conventional structures, is investigated. An important feature of the reinforced beam is significant stress concentrations in the adhesive at the ends of the FRP plate. To reduce these interfacial stresses, a FRP plate with a tapered end is often used. The finite-difference method is utilized in this work to predict the distribution of interfacial stresses in beams strengthened with a FRP plate having a tapered end. Numerical results from the analysis are presented to demonstrate the advantages of using tapers in the design of strengthened beams.

  7. Characteristics of a Linearly Tapered Slot Antenna (LTSA) Conformed Longitudinally Around a Cylinder

    NASA Technical Reports Server (NTRS)

    Jordan, Jennifer L.; Ponchak, George E.; Tavassolian, Negar; Tentzeris, Manos M.

    2007-01-01

    The family of tapered slot antennas (TSA s) is suitable for numerous applications. Their ease of fabrication, wide bandwidth, and high gain make them desirable for military and commercial systems. Fabrication on thin, flexible substrates allows the TSA to be conformed over a given body, such as an aircraft wing or a piece of clothing for wearable networks. Previously, a Double Exponentially Tapered Slot Antenna (DETSA) was conformed around an exponential curvature, which showed that the main beam skewed towards the direction of curvature. This paper presents a Linearly Tapered Slot Antenna (LTSA) conformed longitudinally around a cylinder. Measured and simulated radiation patterns and the direction of maximum H co-polarization (Hco) as a function of the cylinder radius are presented.

  8. Single mode tapered fiber-optic interferometer based refractive index sensor and its application to protein sensing.

    PubMed

    Yadav, T K; Narayanaswamy, R; Abu Bakar, M H; Kamil, Y Mustapha; Mahdi, M A

    2014-09-22

    We demonstrate refractive index sensors based on single mode tapered fiber and its application as a biosensor. We utilize this tapered fiber optic biosensor, operating at 1550 nm, for the detection of protein (gelatin) concentration in water. The sensor is based on the spectroscopy of mode coupling based on core modes-fiber cladding modes excited by the fundamental core mode of an optical fiber when it transitions into tapered regions from untapered regions. The changes are determined from the wavelength shift of the transmission spectrum. The proposed fiber sensor has sensitivity of refractive index around 1500 nm/RIU and for protein concentration detection, its highest sensitivity is 2.42141 nm/%W/V.

  9. Yb3+-doped rod-type amplifiers with local adiabatic tapers for peak power scaling and beam quality improvement

    NASA Astrophysics Data System (ADS)

    Zhu, Yuan; Eschrich, Tina; Leich, Martin; Grimm, Stephan; Kobelke, Jens; Lorenz, Martin; Bartelt, Hartmut; Jäger, Matthias

    2017-10-01

    The use of short local tapers in large mode area fiber amplifiers is proposed for peak power scaling while maintaining good beam quality. To avoid modal distortions, the powder-sintering (REPUSIL) method was employed to obtain core materials with excellent refractive index homogeneity. First experiments with Yb3+-doped rod-type amplifiers delivered 2 ns pulses with peak powers of 540 kW and energies of 1.4 mJ for the untapered rod and 230 kW for the tapered rod (limited by facet damage). The beam quality improved from an M 2 value of approximately 10 to 3.5. The investigation of the taper structure indicates room for further improvement.

  10. Tapered optical fiber sensor based on localized surface plasmon resonance.

    PubMed

    Lin, Hsing-Ying; Huang, Chen-Han; Cheng, Gia-Ling; Chen, Nan-Kuang; Chui, Hsiang-Chen

    2012-09-10

    A tapered fiber localized surface plasmon resonance (LSPR) sensor is demonstrated for refractive index sensing and label-free biochemical detection. The sensing strategy relies on the interrogation of the transmission intensity change due to the evanescent field absorption of immobilized gold nanoparticles on the tapered fiber surface. The refractive index resolution based on the interrogation of transmission intensity change is calculated to be 3.2×10⁻⁵ RIU. The feasibility of DNP-functionalized tapered fiber LSPR sensor in monitoring anti-DNP antibody with different concentrations spiked in buffer is examined. Results suggest that the compact sensor can perform qualitative and quantitative biochemical detection in real-time and thus has potential to be used in biomolecular sensing applications.

  11. Radiation Losses Due to Tapering of a Double-Core Optical Waveguide

    NASA Technical Reports Server (NTRS)

    Lyons, Donald R.; Khet, Myat; Pencil, Eric (Technical Monitor)

    2001-01-01

    The theoretical model we designed parameterizes the power losses as a function of .the profile shape for a tapered, single mode, optical dielectric coupler. The focus of this project is to produce a working model that determines the power losses experienced by the fibers when light crosses a taper region. This phenomenon can be examined using coupled mode theory. The optical directional coupler consists of a parallel, dual-channel, waveguide with minimal spacing between the channels to permit energy exchange. Thus, power transfer is essentially a function of the taper profile. To find the fields in the fibers, the approach used was that of solving the Helmholtz equation in cylindrical coordinates involving Bessel and modified Bessel functions depending on the location.

  12. Acoustic vibration sensor based on nonadiabatic tapered fibers.

    PubMed

    Xu, Ben; Li, Yi; Sun, Miao; Zhang, Zhen-Wei; Dong, Xin-Yong; Zhang, Zai-Xuan; Jin, Shang-Zhong

    2012-11-15

    A simple and low-cost vibration sensor based on single-mode nonadiabatic fiber tapers is proposed and demonstrated. The environmental vibrations can be detected by demodulating the transmission loss of the nonadiabatic fiber taper. Theoretical simulations show that the transmission loss is related to the microbending of the fiber taper induced by vibrations. Unlike interferometric sensors, this vibration sensor does not need any feedback loop to control the quadrature point to obtain a stable performance. In addition, it has no requirement for the coherence of the light source and is insensitive to temperature changes. Experimental results show that this sensing system has a wide frequency response range from a few hertz to tens of kilohertz with the maximal signal to noise ratio up to 73 dB.

  13. Technology Solutions for New and Existing Homes Case Study: Optimized Slab-on-Grade Foundation Insulation Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    T. Schirber; Goldberg, L.; Mosiman, G.

    A more accurate assessment of SOG foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulationmore » at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated).« less

  14. High-Performance Slab-on-Grade Foundation Insulation Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldberg, Louise F.; Mosiman, Garrett E.

    A more accurate assessment of slab-on-grade foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulationmore » at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated).« less

  15. High peak power solid-state laser for micromachining of hard materials

    NASA Astrophysics Data System (ADS)

    Herbst, Ludolf; Quitter, John P.; Ray, Gregory M.; Kuntze, Thomas; Wiessner, Alexander O.; Govorkov, Sergei V.; Heglin, Mike

    2003-06-01

    Laser micromachining has become a key enabling technology in the ever-continuing trend of miniaturization in microelectronics, micro-optics, and micromechanics. New applications have become commercially viable due to the emergence of innovative laser sources, such as diode pumped solid-state lasers (DPSSL), and the progress in processing technology. Examples of industrial applications are laser-drilled micro-injection nozzles for highly efficient automobile engines, or manufacturing of complex spinnerets for production of synthetic fibers. The unique advantages of laser-based techniques stem from their ability to produce high aspect ratio holes, while yielding low heat affected zones with exceptional surface quality, roundness and taper tolerances. Additionally, the ability to drill blind holes and slots in very hard materials such as diamond, silicon, sapphire, ceramics and steel is of great interest for many applications in microelectronics, semiconductor and automotive industry. This kind of high quality, high aspect ratio micromachining requires high peak power and short pulse durations.

  16. [Deformation evaluation of ProTaper nickel-titanium rotary instruments in curved canals instrumentation in vitro].

    PubMed

    Yan, Hong; Ren, Min; Yin, Xing-Zhe; Zhao, Shu-Yan; Zhang, Cheng-Fei

    2008-04-01

    To evaluate the deformation of ProTaper rotary instruments using in root canals of different curvature in vitro. Extracted first mandibular molars were divided into two experimental groups according to the curvature of mesial buccal canals: group A with moderate curvature and group B with severe curvature. Only the mesial buccal canals of all these teeth were prepared with 6 sets of new ProTaper rotary instruments individually. Additionally, the control group was established with a set of new ProTaper rotary instruments. After finishing each canal preparation, the instruments accompanied by control were examined under the stereomicroscope by an inspector without knowing the group. If distortion, unwinding, abrasion or fracture occurred within one set of instruments, then the whole set was disposed. The sets without problems were in use until 30 times. After 5, 10, 20 times canal preparation, S1, F1 files without deformation under stereomicroscope were examined under scanning electron microscope (SEM). Deformation of ProTaper rotary instruments happened after 12 times in group A and after 7 times in group B. In these two experimental groups, microcracks were found increasing with the times of use under SEM in the instruments without deformation under stereomicroscope. The microcracks on tip of instruments were deep in the early use and became smoother after 10 times. Similar changes happened on knife-edge of instruments, and the microcracks extended over the edge after 20 times use. Root canals with severe curvature tend to damage ProTaper rotary instruments more frequently than moderately curved canals. ProTaper rotary instruments are appropriate to treat less than 7 root canals with severe curvature or 12 root canals with moderate curvature. Stereomicroscope is recommended to detect early damages on Ni-Ti rotary instruments, for preventing instruments fracture in clinic.

  17. Microtomography-based comparison of reciprocating single-file F2 ProTaper technique versus rotary full sequence.

    PubMed

    Paqué, Frank; Zehnder, Matthias; De-Deus, Gustavo

    2011-10-01

    A preparation technique with only 1 single instrument was proposed on the basis of the reciprocating movement of the F2 ProTaper instrument. The present study was designed to quantitatively assess canal preparation outcomes achieved by this technique. Twenty-five extracted human mandibular first molars with 2 separate mesial root canals were selected. Canals were randomly assigned to 1 of the 2 experimental groups: group 1, rotary conventional preparation by using ProTaper, and group 2, reciprocate instrumentation with 1 single ProTaper F2 instrument. Specimens were scanned initially and after root canal preparation with an isotropic resolution of 20 μm by using a micro-computed tomography system. The following parameters were assessed: changes in dentin volume, percentage of shaped canal walls, and degree of canal transportation. In addition, the time required to reach working length with the F2 instrument was recorded. Preoperatively, there were no differences regarding root canal curvature and volume between experimental groups. Overall, instrumentation led to enlarged canal shapes with no evidence of preparation errors. There were no statistical differences between the 2 preparation techniques in the anatomical parameters assessed (P > .01), except for a significantly higher canal transportation caused by the reciprocating file in the coronal canal third. On the other hand, preparation was faster by using the single-file technique (P < .01). Shaping outcomes with the single-file F2 ProTaper technique and conventional ProTaper full-sequence rotary approach were similar. However, the single-file F2 ProTaper technique was markedly faster in reaching working length. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  18. Potential relationship between design of nickel-titanium rotary instruments and vertical root fracture.

    PubMed

    Kim, Hyeon-Cheol; Lee, Min-Ho; Yum, Jiwan; Versluis, Antheunis; Lee, Chan-Joo; Kim, Byung-Min

    2010-07-01

    Nickel-titanium (NiTi) rotary files can produce cleanly tapered canal shapes with low tendency of transporting the canal lumen. Because NiTi instruments are generally perceived to have high fracture risk during use, new designs have been marketed to lower fracture risks. However, these design variations may also alter the forces on a root during instrumentation and increase dentinal defects that predispose a root to fracture. This study compared the stress conditions during rotary instrumentation in a curved root for three NiTi file designs. Stresses were calculated using finite element (FE) analysis. FE models of ProFile (Dentsply Maillefer, Ballaigues, Switzerland; U-shaped cross-section and constant 6% tapered shaft), ProTaper Universal (Dentsply; convex triangular cross-section with notch and progressive taper shaft), and LightSpeed LSX (Lightspeed Technology, Inc, San Antonio, TX; noncutting round shaft) were rotated within a curved root canal. The stress and strain conditions resulting from the simulated shaping action were evaluated in the apical root dentin. ProTaper Universal induced the highest von Mises stress concentration in the root dentin and had the highest tensile and compressive principal strain components at the external root surface. The calculated stress values from ProTaper Universal, which had the biggest taper shaft, approached the strength properties of dentin. LightSpeed generated the lowest stresses. The stiffer file designs generated higher stress concentrations in the apical root dentin during shaping of the curved canal, which raises the risk of dentinal defects that may lead to apical root cracking. Thus, stress levels during shaping and fracture susceptibility after shaping vary with instrument design. Copyright 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Influence of design and clinical factors on the removal force ratio in tapered implant-abutment interfaces.

    PubMed

    Aguirrebeitia, Josu; Abasolo, Mikel; Müftü, Sinan; Vallejo, Javier

    2017-04-01

    A previous study investigated the effects of the preload and taper-angle mismatch in tapered implant systems on the removal force characteristics of the self-locking mechanism. The present study builds upon the previous one and introduces the effects of the time elapsed between insertion and removal and the presence of saliva in the implant-abutment interface as 2 new additional parameters. The purpose of this in vitro study was to elucidate the influences of design and clinical parameters on the removal force for implant systems that use tapered interference fit (TIF) type connections by measuring the force needed to remove an abutment from an implant. Ninety-six implants with tapered abutment-implant interfaces specifically built for an unreplicated factorial design were tested on a custom-built workbench for removal force. Four levels were chosen for the preload, F P , and the taper mismatch Δθ; 3 levels for the wait time t; and 2 levels for the saliva presence s at the interface. A regression model was used based on physical reasoning and a theoretical understanding of the interface. A 4-way ANOVA was used to evaluate the influence of the main effects and interactions (α=.05). The experiments strongly indicated that preload, taper mismatch, and saliva presence are relevant variables in removal force. The wait time becomes important when its effect is evaluated along with the preload. The results of this study can be used for decision making in the design and use of TIF type systems. The study supports the use of artificial saliva in any implant design experiment because of its significance in the removal force of the abutment. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Effectiveness of ProTaper Universal retreatment instruments used with rotary or reciprocating adaptive motion in the removal of root canal filling material.

    PubMed

    Capar, I D; Arslan, H; Ertas, H; Gök, T; Saygılı, G

    2015-01-01

    To compare the effectiveness of ProTaper Universal retreatment instruments with continuous rotation and adaptive motion (AM; a modified reciprocating motion that combines rotational and reciprocating motion) in the removal of filling material. Mesiobuccal root canals in 36 mandibular first molars were instrumented up to size F2 with the ProTaper Universal instrument (Dentsply Maillefer, Ballaigues, Switzerland) and filled using sealer and ProTaper Universal F2 gutta-percha cones. Gutta-percha was then down-packed and the root canal backfilled using the extruder hand-piece of the Elements Obturation System (SybronEndo, Orange, CA, USA). The teeth were assigned to two groups (n = 18), and removal of the root fillings was performed using one of the following techniques: group 1) ProTaper Universal retreatment files used with rotational motion (RM) and group 2) ProTaper Universal retreatment files used with adaptive motion (AM) (600° clockwise/0° counter-clockwise to 370° clockwise/50° counter-clockwise). The teeth were sectioned, and both halves were analysed at 8 × magnification. The percentage of remaining filling material was recorded. The data were analysed statistically using the Student's t-test at a 95% confidence level (P < 0.05). There was no significant difference between the groups with respect to the total time required for retreatment (P = 0.481). The AM technique left significantly less filling material than the RM method (P = 0.013). The use of ProTaper Universal retreatment files with adaptive motion removed more filling materials from root canals than the rotational movement. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.