Sample records for tapered titanium femoral

  1. Early Experience with a Short, Tapered Titanium Porous Plasma Sprayed Stem with Updated Design.

    PubMed

    Lombardi, Adolph V; Manocchio, Antonio G; Berend, Keith R; Morris, Michael J; Adams, Joanne B

    2018-06-01

    Short stem femoral components in primary total hip arthroplasty (THA) have increased in popularity since the advent of minimally invasive surgical techniques. The concept of a short stem is particularly compatible with tapered designs where the goal is to offload forces proximally in the femur. The purpose of this retrospective review was to review our early experience with a short, tapered titanium femoral component with updated design features. Beginning in November 2011 through February 2012, 92 consented patients (93 hips), at a single center, were treated with primary cementless THA using a short stem, tapered femoral component (Taperloc® Complete Microplasty; Zimmer Biomet, Warsaw, Indiana) and were available for review with a minimum two-year follow-up. Mean patient age at surgery was 63.2 years and body mass index (BMI) was 30.8 kg/m2. Mean stem length used was 110.3mm (range, 95-125). Mean follow-up was 4.5 years (2-6). Harris hip scores improved from 52.5 preoperatively to 84.7 at most recent. One stem was revised the same day for periprosthetic fracture. One patient with early infection was treated with single-stage exchange followed by recurrence that was treated successfully with two-stage exchange. A non-healing wound in one patient was treated with incision and debridement. Radiographic assessment demonstrated no evidence of loosening, osteolysis, distal hypertrophy, or pedestal formation in any hip, and all components appeared well fixed and in appropriate alignment. In this series of patients treated with primary THA using a short, tapered titanium porous plasma-sprayed femoral component with updated design features, good results were achieved with a low incidence of complications and revision. No aseptic loosening or osteolysis has occurred. Radiographic assessment was excellent for all patients.

  2. Cementless Tapered Wedge Femoral Stems Decrease Subsidence in Obese Patients Compared to Traditional Fit-and-Fill Stems.

    PubMed

    Grant, Tanner W; Lovro, Luke R; Licini, David J; Warth, Lucian C; Ziemba-Davis, Mary; Meneghini, Robert M

    2017-03-01

    Femoral component stability and resistance to subsidence is critical for osseointegration and clinical success in cementless total hip arthroplasty. The purpose of this study was to radiographically evaluate the anatomic fit and subsidence of 2 different proximally tapered, porous-coated modern cementless femoral component designs. A retrospective cohort study of 126 consecutive cementless total hip arthroplasties was performed. Traditional fit-and-fill stems were implanted in the first 61 hips with the remaining 65 receiving morphometric tapered wedge stems. Preoperative bone morphology was radiographically assessed by the canal flare index. Canal fill in the coronal plane, subsidence, and the sagittal alignment of stems was measured digitally on immediate and 1-month postoperative radiographs. Demographics and canal flare indices were similar between groups. The percentage of femoral canal fill was greater in the tapered wedge compared to the fit-and-fill stem (P = .001). There was significantly less subsidence in the tapered wedge design (0.3 mm) compared to the fit-and-fill design (1.1 mm) (P = .001). Subsidence significantly increased as body mass index (BMI) increased in the fit-and-fill stems, a finding not observed in the tapered wedge design (P = .013). An anatomically designed morphometric tapered wedge femoral stem demonstrated greater axial stability and decreased subsidence with increasing BMI than a traditional fit-and-fill stem. The resistance to subsidence, irrespective of BMI, is likely due to the inherent axial stability of a tapered wedge design and may be the optimal stem design for obese patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Microstructure analysis and wear behavior of titanium cermet femoral head with hard TiC layer.

    PubMed

    Luo, Yong; Ge, Shirong; Liu, Hongtao; Jin, Zhongmin

    2009-12-11

    Titanium cermet was successfully synthesized and formed a thin gradient titanium carbide coating on the surface of Ti6Al4V alloy by using a novel sequential carburization under high temperature, while the titanium cermet femoral head was produced. The titanium cermet phase and surface topography were characterized with X-ray diffraction (XRD) and backscattered electron imaging (BSE). And then the wear behavior of titanium cermet femoral head was investigated by using CUMT II artificial joint hip simulator. The surface characterization indicates that carbon effectively diffused into the titanium alloys and formed a hard TiC layer on the Ti6Al4V alloys surface with a micro-porous structure. The artificial hip joint experimental results show that titanium cermet femoral head could not only improve the wear resistance of artificial femoral head, but also decrease the wear of UHMWPE joint cup. In addition, the carburized titanium alloy femoral head could effectively control the UHMWPE debris distribution, and increase the size of UHMWPE debris. All of the results suggest that titanium cermet is a prospective femoral head material in artificial joint.

  4. Trunnion Failure of the Recalled Low Friction Ion Treatment Cobalt Chromium Alloy Femoral Head.

    PubMed

    Urish, Kenneth L; Hamlin, Brian R; Plakseychuk, Anton Y; Levison, Timothy J; Higgs, Genymphas B; Kurtz, Steven M; DiGioia, Anthony M

    2017-09-01

    Gross trunnion failure (GTF) is a rare complication in total hip arthroplasty (THA) reported across a range of manufacturers. Specific lots of the Stryker low friction ion treatment (LFIT) anatomic cobalt chromium alloy (CoCr) V40 femoral head were recalled in August 2016. In part, the recall was based out of concerns for disassociation of the femoral head from the stem and GTF. We report on 28 patients (30 implants) with either GTF (n = 18) or head-neck taper corrosion (n = 12) of the LFIT CoCr femoral head and the Accolade titanium-molybdenum-zirconium-iron alloy femoral stems. All these cases were associated with adverse local tissue reactions requiring revision of the THA. In our series, a conservative estimate of the incidence of failure was 4.7% (n = 636 total implanted) at 8.0 ± 1.4 years from the index procedure. Failures were associated with a high-offset 127° femoral stem neck angle and increased neck lengths; 43.3% (13 of 30) of the observed failures included implant sizes outside the voluntary recall (27.8% [5 of 18] of the GTF and 75.0% [8 of 12] of the taper corrosion cases). Serum cobalt and chromium levels were elevated (cobalt: 8.4 ± 7.0 μg/mL; chromium: 3.4 ± 3.3 μ/L; cobalt/chromium ratio: 3.7). The metal artifact reduction sequence magnetic resonance imaging demonstrated large cystic fluid collections typical with adverse local tissue reactions. During revision, a pseudotumor was observed in all cases. Pathology suggested a chronic inflammatory response. Impending GTF could be diagnosed based on aspiration of black synovial fluid and an oblique femoral head as compared with the neck taper on radiographs. In our series of the recalled LFIT CoCr femoral head, the risk of impending GTF or head-neck taper corrosion should be considered as a potential diagnosis in a painful LFIT femoral head and Accolade titanium-molybdenum-zirconium-iron alloy THA with unknown etiology. Almost half of the failures we observed included sizes outside of the

  5. Comparative study of material loss at the taper interface in retrieved metal-on-polyethylene and metal-on-metal femoral components from a single manufacturer.

    PubMed

    Bills, Paul; Racasan, Radu; Bhattacharya, Saugatta; Blunt, Liam; Isaac, Graham

    2017-08-01

    There have been a number of reports on the occurrence of taper corrosion and/or fretting and some have speculated on a link to the occurrence of adverse local tissue reaction specifically in relation to total hip replacement which have a metal-on-metal bearing. As such a study was carried out to compare the magnitude of material loss at the taper in a series of retrieved femoral heads used in metal-on-polyethylene bearings with that in a series of retrieved heads used in metal-on-metal bearings. A total of 36 metal-on-polyethylene and 21 metal-on-metal femoral components were included in the study all of which were received from a customer complaint database. Furthermore, a total of nine as-manufactured femoral components were included to provide a baseline for characterisation. All taper surfaces were assessed using an established corrosion scoring method and measurements were taken of the female taper surface using a contact profilometry. In the case of metal-on-metal components, the bearing wear was also assessed using coordinate metrology to determine whether or not there was a relationship between bearing and taper material loss in these cases. The study found that in this cohort the median value of metal-on-polyethylene taper loss was 1.25 mm 3 with the consequent median value for metal-on-metal taper loss being 1.75 mm 3 . This study also suggests that manufacturing form can result in an apparent loss of material from the taper surface determined to have a median value of 0.59 mm 3 . Therefore, it is clear that form variability is a significant confounding factor in the measurement of material loss from the tapers of femoral heads retrieved following revision surgery.

  6. [Shaping ability of multi-taper nickel-titanium files in simulated resin curved root canal].

    PubMed

    Luo, Hong-Xia; Huang, Ding-Ming; Jia, Liu-He; Luo, Shi-Gao; Gao, Xiao-Jie; Tan, Hong; Zhou, Xue-Dong

    2006-08-01

    To compare the shaping ability of ISO standard stainless steel K files and multi-taper ProTaper nickel-titanium files in simulated resin curved root canals. METHODS Thirty simulated resin root canals were randomly divided into three groups and prepared by stainless steel K files, hand ProTaper, rotary ProTaper, respectively. The amount of material removed from inner and outer wall and canal width after canal preparation was measured, while the canal curvature before and after canal preparation and canals aberrations were recorded. The stainless steel K files removed more material than hand ProTaper and rotary ProTaper at the outer side of apex and inner side of curvature (P < 0.05). The mean degree of straightening in stainless steel K files group was significantly bigger than in ProTaper group (P < 0.05). The canals prepared by ProTaper had no evident aberration. The shaping ability of ProTaper is better than stainless steel K files.

  7. Impaction Force Influences Taper-Trunnion Stability in Total Hip Arthroplasty.

    PubMed

    Danoff, Jonathan R; Longaray, Jason; Rajaravivarma, Raga; Gopalakrishnan, Ananthkrishnan; Chen, Antonia F; Hozack, William J

    2018-07-01

    This study investigated the influence of femoral head impaction force, number of head strikes, the energy sequence of head strikes, and head offset on the strength of the taper-trunnion junction. Thirty titanium-alloy trunnions were mated with 36-mm zero-offset cobalt-chromium femoral heads of corresponding taper angle. A drop tower impacted the head with 2.5J or 8.25J, resulting in 6 kN or 14 kN impaction force, respectively, in a single strike or combinations of 6 kN + 14 kN or 14 kN + 14 kN. In addition, ten 36-mm heads with -5 and +5 offset were impacted with sequential 14 kN + 14 kN strikes. Heads were subsequently disassembled using a screw-driven mechanical testing frame, and peak distraction force was recorded. Femoral head pull-off force was 45% the strike force, and heads struck with a single 14 kN impact showed a pull-off force twice that of the 6 kN group. Two head strikes with the same force did not improve pull-off force for either 6 kN (P = .90) or 14 kN (P = .90). If the forces of the 2 impactions varied, but either impact measured 14 kN, a 51% higher pull-off force was found compared to impactions of either 6 kN or 6 kN + 6 kN. Femoral head offset did not significantly change the pull-off force among -5, 0, and +5 heads (P = .37). Femoral head impaction force influenced femoral head trunnion-taper stability, whereas offset did not affect pull-off force. Multiple head strikes did not add additional stability, as long as a single strike achieved 14 kN force at the mallet-head impactor interface. Insufficient impaction force may lead to inadequate engagement of the trunnion-taper junction. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Adverse Local Tissue Reaction Arising from Corrosion at the Femoral Neck-Body Junction in a Dual-Taper Stem with a Cobalt-Chromium Modular Neck

    PubMed Central

    Cooper, H. John; Urban, Robert M.; Wixson, Richard L.; Meneghini, R. Michael; Jacobs, Joshua J.

    2013-01-01

    Background: Femoral stems with dual-taper modularity were introduced to allow additional options for hip-center restoration independent of femoral fixation in total hip arthroplasty. Despite the increasing availability and use of these femoral stems, concerns exist about potential complications arising from the modular neck-body junction. Methods: This was a multicenter retrospective case series of twelve hips (eleven patients) with adverse local tissue reactions secondary to corrosion at the modular neck-body junction. The cohort included eight women and three men who together had an average age of 60.1 years (range, forty-three to seventy-seven years); all hips were implanted with a titanium-alloy stem and cobalt-chromium-alloy neck. Patients presented with new-onset and increasing pain at a mean of 7.9 months (range, five to thirteen months) following total hip arthroplasty. After serum metal-ion studies and metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) revealed abnormal results, the patients underwent hip revision at a mean of 15.2 months (range, ten to twenty-three months). Tissue specimens were examined by a single histopathologist, and the retrieved implants were studied with use of light and scanning electron microscopy. Results: Serum metal levels demonstrated greater elevation of cobalt (mean, 6.0 ng/mL) than chromium (mean, 0.6 ng/mL) or titanium (mean, 3.4 ng/mL). MRI with use of MARS demonstrated adverse tissue reactions in eight of nine patients in which it was performed. All hips showed large soft-tissue masses and surrounding tissue damage with visible corrosion at the modular femoral neck-body junction. Available histology demonstrated large areas of tissue necrosis in seven of ten cases, while remaining viable capsular tissue showed a dense lymphocytic infiltrate. Microscopic analysis was consistent with fretting and crevice corrosion at the modular neck-body interface. Conclusions: Corrosion at the modular neck

  9. Asymptomatic Pseudotumors in Patients with Taper Corrosion of a Dual-Taper Modular Femoral Stem: MARS-MRI and Metal Ion Study.

    PubMed

    Kwon, Young-Min; Khormaee, Sariah; Liow, Ming Han Lincoln; Tsai, Tsung-Yuan; Freiberg, Andrew A; Rubash, Harry E

    2016-10-19

    Modularity in total hip arthroplasty facilitates intraoperative restoration of patient anatomy. Although dual-taper modular total hip arthroplasty offers potential advantages for optimizing the hip center of rotation, it has been associated with modular taper corrosion. This corrosion has led to adverse local tissue reactions (pseudotumors) at the neck-stem junction and elevated metal-ion levels. However, the occurrence of taper-corrosion-related pseudotumors in patients who remain asymptomatic following total hip arthroplasty with a dual-taper modular femoral stem remains largely unknown. The aims of this study were (1) to determine the prevalence of asymptomatic pseudotumors by utilizing metal artifact reduction sequence magnetic resonance imaging (MARS-MRI) and (2) compare serum metal-ion levels between symptomatic and asymptomatic patients with a dual-taper modular stem total hip replacement. We performed a retrospective cross-sectional study of 97 consecutive patients who had been treated with a dual-taper modular femoral stem total hip arthroplasty. Eighty-three patients were stratified into symptomatic and asymptomatic groups and evaluated with MARS-MRI, measurement of serum metal-ion levels, and the University of California at Los Angeles (UCLA) functional hip score. The prevalence of pseudotumors as determined with MARS-MRI was 15% in our asymptomatic patients and 36% in the overall cohort. The median serum cobalt level and cobalt/chromium ratio were significantly higher in patients with a pseudotumor than in those without a pseudotumor (8.0 versus 2.0 μg/L [p = 0.004] and 10.3 versus 2.4 μg/L [p = 0.012], respectively). However, there was no significant difference in the serum cobalt level or cobalt/chromium ratio between symptomatic patients with a pseudotumor and asymptomatic patients with a pseudotumor (7.6 versus 6.2 μg/L [p = 0.37] and 8.3 versus 10.6 μg/L [p = 0.46], respectively). The UCLA scores of asymptomatic patients with a pseudotumor were

  10. Principles of managing Vancouver type B periprosthetic fractures around cemented polished tapered femoral stems.

    PubMed

    Quah, Conal; Porteous, Matthew; Stephen, Arthur

    2017-05-01

    The management of periprosthetic fractures around total hip replacements is a complex and challenging problem. Getting it right first time is an important factor in reducing the morbidity, mortality and financial burden associated with these injuries. Understanding and applying the basic principles of fracture management helps increase the chance of successful treatment. Based on these principles, we suggest a treatment algorithm for managing periprosthetic fractures around polished tapered femoral stems.

  11. Modular femoral component for conversion of previous hip surgery in total hip arthroplasty.

    PubMed

    Goldstein, Wayne M; Branson, Jill J

    2005-09-01

    The conversion of previous hip surgery to total hip arthroplasty creates a durable construct that is anatomically accurate. Most femoral components with either cemented or cementless design have a fixed tapered proximal shape. The proximal femoral anatomy is changed due to previous hip surgery for fixation of an intertrochanteric hip fracture, proximal femoral osteotomy, or a fibular allograft for avascular necrosis. The modular S-ROM (DePuy Orthopaedics Inc., Warsaw, Ind) hip stem accommodates these issues and independently prepares the proximal and distal portion of the femur. In preparation and implantation, the S-ROM hip stem creates less hoop stresses on potentially fragile stress risers from screws and thin bone. The S-ROM hip stem also prepares a previously distorted anatomy by milling through cortical bone that can occlude the femoral medullar canals and recreate proper femoral anteversion and reduces the risk of intraoperative or postoperative periprosthetic fracture due to the flexible titanium-slotted stem. The S-ROM femoral stem is recommended for challenging total hip reconstructions.

  12. Treatment of pediatric femoral shaft fractures by stainless steel and titanium elastic nail system: A randomized comparative trial.

    PubMed

    Gyaneshwar, Tank; Nitesh, Rustagi; Sagar, Tomar; Pranav, Kothiyal; Rustagi, Nitesh

    2016-08-01

    Literature suggests that the lower modulus of elasticity of titanium makes it ideal for use in children compared with stainless steel. Better fracture stability was observed in association with titanium nails on torsional and axial compression testing. However, stainless steel nails are stiffer than titanium counterparts, which may provide a rigid construct when fixing paediatric femoral shaft fractures. Complications have been observed more frequently by various researchers when titanium nails are used for fracture fixation in patients with increasing age or weight. The concept of this study was to compare the functional outcome after internal fixation with titanium elastic nail system and stainless steel elastic nail system in paediatric femoral shaft fractures. The study was conducted on 34 patients admitted in the department of orthopaedics, LLRM Medical College & SVBP Hospital, Meerut, India from January 2013 to August 2014. We included patients aged 5-12 years with fracture of the femoral shaft, excluding compound fractures, pathological fractures and other lower limb fractures. Patients were treated by titanium (n=17) or stainless steel (n=17) elastic nail system and followed up for one year. The clinical parameters like range of motion at hip and knee joints, time to full weight bearing on the operated limb and radiological parameters like time to union were compared between two groups. A special note was made of intra- and post-operative complications. Functional outcomes were analysed according to Flynn criteria. Based on the Flynn criteria, 59% of patients had excellent results, 41% had satisfactory results, and no one showed poor results. There was no clinically significant difference between the two groups with respect to time to union and full weight bearing. But the incidence of puncture of the opposite cortex while inserting the nail and trying to advance it through the diaphysis during operation is greatly different. Only one such case was observed

  13. Endodontic shaping performance using nickel-titanium hand and motor ProTaper systems by novice dental students.

    PubMed

    Tu, Ming-Gene; Chen, San-Yue; Huang, Heng-Li; Tsai, Chi-Cheng

    2008-05-01

    Preparing a continuous tapering conical shape and maintaining the original shape of a canal are obligatory in root canal preparation. The purpose of this study was to compare the shaping performance in simulated curved canal resin blocks of the same novice dental students using hand-prepared and engine-driven nickel-titanium (NiTi) rotary ProTaper instruments in an endodontic laboratory class. Twenty-three fourth-year dental students attending China Medical University Dental School prepared 46 simulated curved canals in resin blocks with two types of NiTi rotary systems: hand and motor ProTaper files. Composite images were prepared for estimation. Material removed, canal width and canal deviation were measured at five levels in the apical 4 mm of the simulated curved canals using AutoCAD 2004 software. Data were analyzed using Wilcoxon's rank-sum test. The hand ProTaper group cut significantly wider than the motor rotary ProTaper group in the outer wall, except for the apical 0 mm point. The total canal width was cut significantly larger in the hand group than in the motor group. There was no significant difference between the two groups in centering canal shape, except at the 3 mm level. These findings show that the novice students prepared the simulated curved canal that deviated more outwardly from apical 1 mm to 4 mm using the hand ProTaper. The ability to maintain the original curvature was better in the motor rotary ProTaper group than in the hand ProTaper group. Undergraduate students, if following the preparation sequence carefully, could successfully perform canal shaping by motor ProTaper files and achieve better root canal geometry than by using hand ProTaper files within the same teaching and practicing sessions.

  14. Ammonia sensing using lossy mode resonances in a tapered optical fibre coated with porphyrin-incorporated titanium dioxide

    NASA Astrophysics Data System (ADS)

    Tiwari, Divya; Mullaney, Kevin; Korposh, Serhiy; James, Stephen W.; Lee, Seung-Woo; Tatam, Ralph P.

    2016-05-01

    The development of an ammonia sensor, formed by the deposition of a functionalised titanium dioxide film onto a tapered optical fibre is presented. The titanium dioxide coating allows the coupling of light from the fundamental core mode to a lossy mode supported by the coating, thus creating lossy mode resonance (LMR) in the transmission spectrum. The porphyrin compound that was used to functionalise the coating was removed from the titanium dioxide coating upon exposure to ammonia, causing a change in the refractive index of the coating and a concomitant shift in the central wavelength of the lossy mode resonance. Concentrations of ammonia as small as 1ppm was detected with a response time of less than 1min.

  15. Neck fracture of a cementless forged titanium alloy femoral stem following total hip arthroplasty: a case report and review of the literature

    PubMed Central

    Grivas, Theodoros B; Savvidou, Olga D; Psarakis, Spyridon A; Bernard, Pierre-Francois; Triantafyllopoulos, George; Kovanis, Ioannis; Alexandropoulos, Panagiotis

    2007-01-01

    Introduction Fractures of the neck of the femoral component have been reported in uncemented total hip replacements, however, to our knowledge, no fractures of the neck of a cementless forged titanium alloy femoral stem coated in the proximal third with hydroxy-apatite have been reported in the medical literature. Case presentation This case report describes a fracture of the neck of a cementless forged titanium alloy stem coated in the proximal third with hydroxy-apatite. Conclusion The neck of the femoral stem failed from fatigue probably because of a combination of factors described analytically below. PMID:18062807

  16. The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments.

    PubMed

    Özyürek, Taha; Yılmaz, Koray; Uslu, Gülşah

    2017-11-01

    It was aimed to compare the cyclic fatigue resistances of ProTaper Universal (PTU), ProTaper Next (PTN), and ProTaper Gold (PTG) and the effects of sterilization by autoclave on the cyclic fatigue life of nickel-titanium (NiTi) instruments. Eighty PTU, 80 PTN, and 80 PTG were included to the present study. Files were tested in a simulated canal. Each brand of the NiTi files were divided into 4 subgroups: group 1, as received condition; group 2, pre-sterilized instruments exposed to 10 times sterilization by autoclave; group 3, instruments tested were sterilized after being exposed to 25%, 50%, and 75% of the mean cycles to failure, then cycled fatigue test was performed; group 4, instruments exposed to the same experiment with group 3 without sterilization. The number of cycles to failure (NCF) was calculated. The data was statistically analyzed by using one-way analysis of variance and post hoc Tukey tests. PTG showed significantly higher NCF than PTU and PTN in group 1 ( p < 0.05). Sterilization significantly increased the NCF of PTN and PTG ( p < 0.05) in group 2. PTN in group 3 had significantly higher cyclic fatigue resistance than PTN group 4 ( p < 0.05). Also, significantly higher NCF was observed for PTG in group 2 than in groups 3 and 4 ( p < 0.05). PTG instrument made of new gold alloy was more resistant to fatigue failure than PTN and PTU. Autoclaving increased the cyclic fatigue resistances of PTN and PTG.

  17. The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments

    PubMed Central

    2017-01-01

    Objectives It was aimed to compare the cyclic fatigue resistances of ProTaper Universal (PTU), ProTaper Next (PTN), and ProTaper Gold (PTG) and the effects of sterilization by autoclave on the cyclic fatigue life of nickel-titanium (NiTi) instruments. Materials and Methods Eighty PTU, 80 PTN, and 80 PTG were included to the present study. Files were tested in a simulated canal. Each brand of the NiTi files were divided into 4 subgroups: group 1, as received condition; group 2, pre-sterilized instruments exposed to 10 times sterilization by autoclave; group 3, instruments tested were sterilized after being exposed to 25%, 50%, and 75% of the mean cycles to failure, then cycled fatigue test was performed; group 4, instruments exposed to the same experiment with group 3 without sterilization. The number of cycles to failure (NCF) was calculated. The data was statistically analyzed by using one-way analysis of variance and post hoc Tukey tests. Results PTG showed significantly higher NCF than PTU and PTN in group 1 (p < 0.05). Sterilization significantly increased the NCF of PTN and PTG (p < 0.05) in group 2. PTN in group 3 had significantly higher cyclic fatigue resistance than PTN group 4 (p < 0.05). Also, significantly higher NCF was observed for PTG in group 2 than in groups 3 and 4 (p < 0.05). Conclusions PTG instrument made of new gold alloy was more resistant to fatigue failure than PTN and PTU. Autoclaving increased the cyclic fatigue resistances of PTN and PTG. PMID:29142878

  18. Is there still a place for the cemented titanium femoral stem?

    PubMed Central

    2012-01-01

    Background and purpose Despite the fact that there have been some reports on poor performance, titanium femoral stems intended for cemented fixation are still used at some centers in Europe. In this population-based registry study, we examined the results of the most frequently used cemented titanium stem in Norway. Patients and methods 11,876 cases implanted with the cemented Titan stem were identified for the period 1987–2008. Hybrid arthroplasties were excluded, leaving 10,108 cases for this study. Stem survival and the influence of age, sex, stem offset and size, and femoral head size were evaluated using Cox regression analyses. Questionnaires were sent to the hospitals to determine the surgical technique used. Results Male sex, high stem offset, and small stem size were found to be risk factors for stem revision, (adjusted RR = 2.5 (1.9–3.4), 3.3 (2.3–4.8), and 2.2 (1.4–3.5), respectively). Patients operated in the period 2001–2008 had an adjusted relative risk (RR) of 4.7 (95% CI: 3.0–7.4) for stem revision due to aseptic stem loosening compared to the period 1996–2000. Changes in broaching technique and cementing technique coincided with deterioration of the results in some hospitals. Interpretation The increased use of small stem sizes and high-offset stems could only explain the deterioration of results to a certain degree since the year 2000. The influence of discrete changes in surgical technique over time could not be fully evaluated in this registry study. We suggest that this cemented titanium stem should be abandoned. The results of similar implants should be carefully evaluated. PMID:22206445

  19. Cerclage wires or cables for the management of intraoperative fracture associated with a cementless, tapered femoral prosthesis: results at 2 to 16 years.

    PubMed

    Berend, Keith R; Lombardi, Adolph V; Mallory, Thomas H; Chonko, Douglas J; Dodds, Kathleen L; Adams, Joanne B

    2004-10-01

    Initial stability is critical for fixation and survival of cementless total hip arthroplasty. Occasionally, a split of the calcar occurs intraoperatively. A review of 1,320 primary total hip arthroplasties with 2-year follow-up, performed between August 1985 and February 2001 using the Mallory-Head Porous tapered femoral component, revealed 58 hips in 55 patients with an intraoperative calcar fracture managed with single or multiple cerclage wires or cables and immediate full weight bearing. At 7.5 years average follow-up (range, 2-16 years), there were no revisions of the femoral component, radiographic failures, or patients with severe thigh pain, for a stem survival rate of 100%. Average Harris hip score improvement was 33.8 points. Fracture of the proximal femur occurs in approximately 4% of primary THAs using the Mallory-Head Porous femoral component. When managed intraoperatively with cerclage wire or cable, the mid- to long-term results appear unaffected with 100% femoral component survival at up to 16 years.

  20. Sealing ability of lateral compaction and tapered single cone gutta-percha techniques in root canals prepared with stainless steel and rotary nickel titanium instruments.

    PubMed

    Koçak, Mustafa M; Darendeliler-Yaman, Sis

    2012-07-01

    The aim of this study was to evaluate the sealing ability of lateral compaction and tapered single cone gutta-percha techniques in root canals prepared with stainless steel and rotary nickel titanium root canal instruments by fluid filtration method. The root canals were prepared with stainless steel (SS) and nickel titanium (NiTi) instruments. The canals prepared with SS were obturated with lateral compaction technique using .02 tapered cones and the canals prepared with NiTi instruments were obturated with lateral compaction technique using .02 tapered cones or 06 tapered single cones. The amount of leakage was evaluated by fluid filtration model. The results were statistically analyzed with one-way ANOVA. The group prepared with NiTi instruments and filled with lateral compaction technique showed significantly less coronal leakage than the group prepared with SS instruments and filled with lateral compaction technique (p<0.05). There was no statistically difference between apical leakages of groups (p>0.05). Obturation with lateral compaction of gutta-percha provides a superior coronal seal whilst canal instrumentation with engine-driven NiTi files reduces the extent of microleakage in root canals when compared with stainless steel hand instruments. Tapered single cone technique was comparable with lateral compaction technique because of easier application. Key words:Apical leakage, coronal leakage, lateral compaction technique, single cone technique.

  1. Shaping ability of ProFile.04 Taper Series 29 rotary nickel-titanium instruments in simulated root canals. Part 1.

    PubMed

    Thompson, S A; Dummer, P M

    1997-01-01

    The aim of this study was to determine the shaping ability of ProFile.04 Taper Series 29 nickel-titanium instruments in simulated canals. A total of 40 simulated root canals made up of four different shapes in terms of angle and position of curvature were prepared by ProFile instruments using a step-down approach. Part 1 of this two-part report describes the efficacy of the instruments in terms of preparation time, instrument failure, canal blockages, loss of canal length and three-dimensional canal form. The time necessary for canal preparation was not influenced significantly by canal shape. No instrument fractures occurred but a total of 52 instruments deformed. Size 6 instruments deformed the most followed by sizes 5, 3 and 4. Canal shape did not influence significantly instrument deformation. None of the canals became blocked with debris and loss of working distance was on average 0.5 mm or less. Intracanal impressions of canal form demonstrated that most canals had definite apical stops, smooth canal walls and good flow and taper. Under the conditions of this study, ProFile.04 Taper Series 29 rotary nickel-titanium instruments prepared simulated canals rapidly and created good three-dimensional form. A substantial number of instruments deformed but it was not possible to determine whether this phenomenon occurred because of the nature of the experimental model or through an inherent design weakness in the instruments.

  2. 3D-printed porous titanium changed femoral head repair growth patterns: osteogenesis and vascularisation in porous titanium.

    PubMed

    Zhu, Wei; Zhao, Yan; Ma, Qi; Wang, Yingjie; Wu, Zhihong; Weng, Xisheng

    2017-04-01

    Osteonecrosis of the femoral head (ONFH) is a major cause of morbidity, and total hip arthroplasty is both traumatic and expensive. Here, we created a gelatine scaffold embedded in uniquely shaped, 3D-printed porous titanium parts, which could attract and promote the proliferation of osteoblasts as well as bone regeneration, as the extracellular matrix (ECM) does in vivo. Interestingly, after hybridisation with platelets, the scaffold exhibited a low yet considerable rate of stable, safe and long-term growth factor release. Additionally, a novel ONFH model was constructed and verified. Scaffolds implanted in this model were found to accelerate bone repair. In conclusion, our scaffold successfully simulates the ECM and considerably accelerates bone regeneration, in which platelets play an indispensable role. We believe that platelets should be emphasised as carriers that may be employed to transport drugs, cytokines and other small molecules to target locations in vivo. In addition, this novel scaffold is a useful material for treating ONFH. An overview of the novel scaffold mimicking the extracellular environment in bone repair. a and b: A gelatine scaffold was cross-linked and freeze-dried within 3D-printed porous titanium. c: Platelets were coated onto the gelatine microscaffold after freeze-drying platelet-rich plasma. d: The microscaffold supported the migration of cells into the titanium pores and their subsequent growth, while the platelets slowly released cell factors, exerting bioactivity.

  3. Ceramic Heads Decrease Metal Release Caused by Head-taper Fretting and Corrosion.

    PubMed

    Kocagoz, Sevi B; Underwood, Richard J; MacDonald, Daniel W; Gilbert, Jeremy L; Kurtz, Steven M

    2016-04-01

    Metal release resulting from taper fretting and corrosion is a clinical concern, because wear and corrosion products may stimulate adverse local tissue reactions. Unimodular hip arthroplasties have a conical taper between the femoral head (head bore taper) and the femoral stem (stem cone taper). The use of ceramic heads has been suggested as a way of reducing the generation of wear and corrosion products from the head bore/stem cone taper junction. A previous semiquantitative study found that ceramic heads had less visual evidence of fretting-corrosion damage compared with CoCr heads; but, to our knowledge, no studies have quantified the volumetric material loss from the head bore and stem cone tapers of a matched cohort of ceramic and metal heads. We asked: (1) Do ceramic heads result in less volume of material loss at the head-stem junction compared with CoCr heads; (2) do stem cone tapers have less volumetric material loss compared with CoCr head bore tapers; (3) do visual fretting-corrosion scores correlate with volumetric material loss; and (4) are device, patient, or intraoperative factors associated with volumetric material loss? A quantitative method was developed to estimate volumetric material loss from the head and stem taper in previously matched cohorts of 50 ceramic and 50 CoCr head-stem pairs retrieved during revision surgery for causes not related to adverse reactions to metal particles. The cohorts were matched according to (1) implantation time, (2) stem flexural rigidity, and (3) lateral offset. Fretting corrosion was assessed visually using a previously published four-point, semiquantitative scoring system. The volumetric loss was measured using a precision roundness machine. Using 24 equally spaced axial traces, the volumetric loss was estimated using a linear least squares fit to interpolate the as-manufactured surfaces. The results of this analysis were considered in the context of device (taper angle clearance, head size, head offset

  4. Total Hip Arthroplasty Using a Polished Tapered Cemented Stem in Hereditary Multiple Exostosis

    PubMed Central

    Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko

    2016-01-01

    A 61-year-old Japanese man underwent right total hip arthroplasty for hereditary multiple exostosis. At first presentation, he had suffered from coxalgia for a long time. On radiographic images, there was a gigantic femoral head, increased shaft angle, and large diameter of the femoral neck. He had also developed coxarthrosis and severe pain of the hip joint. The transformation of the proximal femur bone causes difficulty in setting a cementless total hip prosthesis. Therefore, total hip arthroplasty using a cemented polished tapered stem was performed via a direct lateral approach. Using a cemented polished tapered stem allowed us to deal with the femoral bone transformation and bone substance defectiveness due to exostosis and also minimized the invasiveness of the operation. PMID:27127668

  5. Retrieval analysis of titanium nitride (TiN) coated prosthetic femoral heads articulating with polyethylene.

    PubMed

    Łapaj, Łukasz; Wendland, Justyna; Markuszewski, Jacek; Mróz, Adrian; Wiśniewski, Tomasz

    2015-03-01

    Data regarding in vivo performance of titanium nitride (TiN) coated prosthetic femoral heads is scarce, and available studies of older generations of implants demonstrated coating wear in vivo. That is why we conducted a retrieval analysis of 11 femoral heads (articulating in vivo for 1-56 months) with TiN film formed using physical vapor deposition (PVD), to verify if coating failure is a problem in contemporary implants. Retrieved implants were examined using scanning electron microscope, coating roughness was evaluated with a contact profilometer and adhesion was tested using a Rockwell HRC test according to VDI 3824 guideline. Although no gross failure of the TiN coating was observed in our retrievals, all implants had defects typical for PVD coatings, such as pinholes, small titanium droplets and blisters with delaminated coating. In some heads the coating was contaminated with small niobium (Nb) droplets uniformly scattered on the entire surface of the film. Presence of Nb contamination was associated with an increased number and area of other types of defects and poorer coating adhesion. In one component, subjected to multiple dislocations we found severe delamination and cracking of the coating, increased roughness and the presence of third bodies. Our results indicate, that although wear of the coating is lower than seen in older generations of implants, inconsistent quality of the TiN film among different implants indicates the need for strict monitoring of the manufacturing process. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Evaluation of the Painful Dual Taper Modular Neck Stem Total Hip Arthroplasty: Do They All Require Revision?

    PubMed

    Kwon, Young-Min

    2016-07-01

    Although dual taper modular-neck total hip arthroplasty (THA) design with additional neck-stem modularity has the potential to optimize hip biomechanical parameters by facilitating adjustments of leg length, femoral neck version and offset, there is increasing concern regarding this stem design as a result of the growing numbers of adverse local tissue reactions due to fretting and corrosion at the neck-stem taper junction. Implant factors such as taper cone angle, taper surface roughness, taper contact area, modular neck taper metallurgy, and femoral head size play important roles in influencing extent of taper corrosion. There should be a low threshold to conduct a systematic clinical evaluation of patients with dual-taper modular-neck stem THA using systematic risk stratification algorithms as early recognition and diagnosis will ensure prompt and appropriate treatment. Although specialized tests such as metal ion analysis and cross-sectional imaging modalities such as metal artifact reduction sequence magnetic resonance imaging (MARS MRI) are useful in optimizing clinical decision-making, overreliance on any single investigative tool in the clinical decision-making process for revision surgery should be avoided. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. A short tapered stem reduces intraoperative complications in primary total hip arthroplasty.

    PubMed

    Molli, Ryan G; Lombardi, Adolph V; Berend, Keith R; Adams, Joanne B; Sneller, Michael A

    2012-02-01

    While short-stem design is not a new concept, interest has surged with increasing utilization of less invasive techniques. Short stems are easier to insert through small incisions. Reliable long-term results including functional improvement, pain relief, and implant survival have been reported with standard tapered stems, but will a short taper perform as well? We compared short, flat-wedge, tapered, broach-only femoral stems to standard-length, double-tapered, ream and broach femoral stems in terms of intraoperative complications, short-term survivorship, and pain and function scores. We retrospectively reviewed the records of 606 patients who had 658 THAs using a less invasive direct lateral approach from January 2006 to March 2008. Three hundred sixty patients (389 hips) had standard-length stems and 246 (269 hips) had short stems. Age averaged 63 years, and body mass index averaged 30.7 kg/m(2). We recorded complications and pain and function scores and computed short-term survival. Minimum followup was 0.8 months (mean, 29.2 months; range, 0.8-62.2 months). We observed a higher rate of intraoperative complications with the standard-length stems (3.1%; three trochanteric avulsions, nine femoral fractures) compared with the shorter stems (0.4%; one femoral fracture) and managed all complications with application of one or more cerclage cables. There were no differences in implant survival, Harris hip score, and Lower Extremity Activity Scale score between groups. Fewer intraoperative complications occurred with the short stems, attesting to the easier insertion of these devices. While longer followup is required, our early results suggest shortened stems can be used with low complication rates and do not compromise the survival and functional outcome of cementless THA. Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  8. Fretting and Corrosion Damage in Taper Adapter Sleeves for Ceramic Heads: A Retrieval Study.

    PubMed

    MacDonald, Daniel W; Chen, Antonia F; Lee, Gwo-Chin; Klein, Gregg R; Mont, Michael A; Kurtz, Steven M; Cates, Harold E; Kraay, Matthew J; Rimnac, Clare M

    2017-09-01

    During revision surgery with a well-fixed stem, a titanium sleeve can be used in conjunction with a ceramic head to achieve better stress distribution across the taper surface. In vitro testing suggests that corrosion is not a concern in sleeved ceramic heads; however, little is known about the in vivo fretting corrosion of the sleeves. The purpose of this study was to investigate fretting corrosion in sleeved ceramic heads in retrieved total hip arthroplasties. Thirty-seven sleeved ceramic heads were collected during revision. The femoral heads and sleeves were implanted 0.0-3.3 years. The implants were revised predominantly for instability, infection, and loosening. Fifty percent of the retrievals were implanted during a primary surgery. Fretting corrosion was assessed using the Goldberg-Higgs semiquantitative scoring system. Mild-to-moderate fretting corrosion scores (score = 2-3) were observed in 92% of internal tapers, 19% of external tapers, and 78% of the stems. Severe fretting corrosion was observed in 1 stem trunnion that was previously retained during revision surgery and none of the retrieved sleeves. There was no difference in corrosion damage of sleeves used in primary or revision surgery. The fretting corrosion scores in this study were predominantly mild and lower than reported fretting scores of cobalt-chrome heads in metal-on-polyethylene bearings. Although intended for use in revisions, we found that the short-term in vivo corrosion behavior of the sleeves was similar in both primary and revision surgery applications. From an in vivo corrosion perspective, sleeves are a reasonable solution for restoring the stem taper during revision surgery. Copyright © 2017. Published by Elsevier Inc.

  9. [Comparison of the treatment of slipped capital femoral epiphysis with K-wires and cannulated titanium screws].

    PubMed

    Maus, U; Ihme, N; Niedhart, C; Abeler, E; Kochs, A; Gravius, S; Ohnsorge, J A K; Andereya, S

    2008-01-01

    The treatment of slipped capital femoral epiphysis (SCFE) is usually treated operatively, but there is still no consensus about the method to be used. Up to a 30 degrees degree of slipping, the epiphysis is normally fixed in situ. The aim of our study was to compare the intermediate results after fixation in situ by K-wires versus cannulated titanium screws (Königsee-Implantate, Königsee-Aschau, Germany). In this study 46 patients with SCFE grade I and II and mostly chronic slipping of the epiphysis were included. After fixation in situ and, if necessary, careful, closed reposition, the patients were clinically and radiologically followed-up for one year. The clinical results were documented by the score adapted from Heyman and Herndon. Furthermore, MRI scans were done to evaluate the vitality of the epiphysis pre- and postoperatively, when titanium screws were used. Clinical follow-up showed comparable results in the clinical scores after fixation by K-wires or cannulated titanium screws (3.13 +/- 1.02 vs. 3.10 +/- 1.01). After the treatment with titanium screws we saw a higher rate of abnormal gait (33.3 % vs. 19 %), a decreased rate of the positive Drehmann sign (10 % vs. 38 %) and a lower rate of revisions (16 % vs. 50 %) in comparison to K-wire fixation. After displacement of the K-wires we saw chondrolysis and prearthrosis in one case. Removal of the K-wires was done without any complications, while the removal of the cannulated titanium screws failed in 4 of 10 cases. The treatment of SCFE with K-wires and cannulated titanium screws showed comparable results in the clinical follow-up. The treatment with cannulated titanium screws reduces the number of necessary revisions, but the removal of the material is hindered. Because of the lower rate of complications we prefer in the meantime the use of cannulated steel screws.

  10. Do Stem Taper Microgrooves Influence Taper Corrosion in Total Hip Arthroplasty? A Matched Cohort Retrieval Study.

    PubMed

    Arnholt, Christina M; MacDonald, Daniel W; Underwood, Richard J; Guyer, Eric P; Rimnac, Clare M; Kurtz, Steven M; Mont, Michael A; Klein, Gregg R; Lee, Gwo-Chin; Chen, Antonia F; Hamlin, Brian R; Cates, Harold E; Malkani, Arthur L; Kraay, Matthew J

    2017-04-01

    Previous studies identified imprinting of the stem morphology onto the interior head bore, leading researchers to hypothesize an influence of taper topography on mechanically assisted crevice corrosion. The purpose of this study was to analyze whether microgrooved stem tapers result in greater fretting corrosion damage than smooth stem tapers. A matched cohort of 120 retrieved head-stem pairs from metal-on-polyethylene bearings was created controlling for implantation time, flexural rigidity, apparent length of engagement, and head size. There were 2 groups of 60 heads each, mated with either smooth or microgrooved stem tapers. A high-precision roundness machine was used to measure and categorize the surface morphology. Fretting corrosion damage at the head-neck junction was characterized using the Higgs-Goldberg scoring method. Fourteen of the most damaged heads were analyzed for the maximum depth of material loss and focused ion beam cross-sectioned to view oxide and base metal. Fretting corrosion damage was not different between the 2 cohorts at the femoral head (P = .14, Mann-Whitney) or stem tapers (P = .35). There was no difference in the maximum depths of material loss between the cohorts (P = .71). Cross-sectioning revealed contact damage, signs of micro-motion, and chromium-rich oxide layers in both cohorts. Microgroove imprinting did not appear to have a different effect on the fretting corrosion behavior. The results of this matched cohort retrieval study do not support the hypothesis that taper surfaces with microgrooved stems exhibit increased in vivo fretting corrosion damage or material release. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Hydroxyapatite in total hip arthroplasty. Our experience with a plasma spray porous titanium alloy/hydroxyapatite double-coated cementless stem.

    PubMed

    Castellini, Iacopo; Andreani, Lorenzo; Parchi, Paolo Domenico; Bonicoli, Enrico; Piolanti, Nicola; Risoli, Francesca; Lisanti, Michele

    2016-01-01

    titanium alloy/hydroxyapatite double coating, this study reported an excellent implant survival rate in a mid-term period with a rate of 1,64% of subsidence in patients with type C of femoral canal but with an optimal HHS and Womac Score results. Regarding this stem, primary stability is guaranteed by trapezoid shape of proximal region and tapering in frontal plane through press-fit technique. Radiological absence of pedestal has been accepted as sign of no excessive stress transmission to distal cortex due to its tapered diaphyseal region. Thanks to the reported data, Authors can consider this double coating a valid choice with an excellent medium-term survival and encouraging subsidence results. Further studies are needed to ensure these results can be replicated.

  12. Total Hip Intraoperative Femur Fracture: Do the Design Enhancements of a Second-Generation Tapered-Wedge Stem Reduce the Incidence?

    PubMed

    Colacchio, Nicholas D; Robbins, Claire E; Aghazadeh, Mehran S; Talmo, Carl T; Bono, James V

    2017-10-01

    Intraoperative femur fracture (IFF) is a well-known complication in primary uncemented total hip arthroplasty (THA). Variations in implant instrumentation design and operative technique may influence the risk of IFF. This study investigates IFF between a standard uncemented tapered-wedge femoral stem and its second-generation successor with the following design changes: size-specific medial curvature, proportional incremental stem growth, modest reduction in stem length, and distal lateral relief. A single experienced surgeon's patient database was retrospectively queried for IFF occurring during primary uncemented THA using a standard tapered-wedge femoral stem system or a second-generation stem. All procedures were performed using soft tissue preserving anatomic capsule repair and posterior approach. The primary outcome measure was IFF. A z-test of proportions was performed to determine significant difference between the 2 stems with respect to IFF. Patient demographics, Dorr classification, and implant characteristics were also examined. Forty-one of 1510 patients (2.72%) who received a standard tapered-wedge femoral stem sustained an IFF, whereas 5 of 800 patients (0.63%) using the second-generation stem incurred an IFF. No other significant associations were found. A standard tapered-wedge femoral stem instrumentation system resulted in greater than 4 times higher incidence of IFF than its second-generation successor used for primary uncemented THA. Identifying risk factors for IFF is necessary to facilitate implant system improvements and thus maximize patient outcomes. Copyright © 2017. Published by Elsevier Inc.

  13. Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary files.

    PubMed

    Elnaghy, A M

    2014-11-01

    To compare the cyclic fatigue resistance of ProTaper Next files (PTN; Dentsply Maillefer, Ballaigues, Switzerland) with Twisted Files (TF; SybronEndo, Orange, CA, USA), HyFlex CM (HF; ColténeEndo/Whaledent, Inc, Cuyahoga Falls, OH, USA) and ProTaper Universal (PT; Dentsply Maillefer). Size 25, .06 taper for PTN X2, TF, HF and PT F1 size 20, .07 taper were rotated in simulated canals until failure, and the number of cycles to failure (NCF) was recorded to evaluate their cyclic fatigue resistance. A scanning electron microscope was used to characterize the topographic features of the fracture surfaces of broken files. The data of the NCF and fragment length values were analysed statistically using one-way analysis of variance and Tukey post hoc tests. Statistical significance level was set at P < 0.05. Twisted Files had a significantly higher resistance to cyclic fatigue than the other instruments (P < 0.05). No significant difference was found in NCF between PTN and HF (P > 0.05); however, there was a significant difference (P < 0.05) of both these systems with PT, which exhibited the lowest mean NCF. The ranking in the NCF values was: TF > PTN > HF > PT. The fracture cross-sections of all brands revealed similar fractographic features, including crack origins, fatigue zone and an overload fast fracture zone. The new ProTaper Next had greater resistance to cyclic fatigue compared with ProTaper and HyFlex CM but not the Twisted Files. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  14. Cyclic fatigue resistance of D-RaCe, ProTaper, and Mtwo nickel-titanium retreatment instruments after immersion in sodium hypochlorite.

    PubMed

    Topçuoğlu, Hüseyin Sinan; Pala, Kanşad; Aktı, Ahmet; Düzgün, Salih; Topçuoğlu, Gamze

    2016-07-01

    The aim of this study was to investigate the effect of immersion in sodium hypochlorite (NaOCl) on cyclic fatigue resistance of three different rotary nickel-titanium (NiTi) retreatment files. A total of 90 new ProTaper, D-RaCe, and Mtwo retreatment files were tested. Thirty files of the same brand were randomly assigned to two groups (n = 15). Group 1 was no immersion (control group) and 16 mm of group 2 instruments were immersed in 5 % NaOCl at 37 °C for 5 min. All instruments were then tested for cyclic fatigue. Resistance to cyclic fatigue was determined by counting the numbers of cycles to failure in a 60° curve with a 5-mm radius, recording the time in seconds to fracture. Data were analyzed by two-way analysis of variance. Resistance to cyclic fatigue decreased significantly for D-RaCe retreatment files after immersion in NaOCl. ProTaper and Mtwo retreatment files were not affected from immersion to NaOCl. D-RaCe retreatment instruments showed better cyclic fatigue resistance than ProTaper and Mtwo retreatment instruments, and the difference was statistically significant (p < 0.05). There was no significant difference between ProTaper and Mtwo retreatment instrument groups (p > 0.05). D-RaCe retreatment instruments had the highest cyclic fatigue resistance among retreatment files tested in this study, but immersion to NaOCl decreased the cyclic fatigue resistance of D-RaCe retreatment instrument. It should be considered that cyclic fatigue resistance of D-RaCe can decrease in contact with NaOCl during the removal of canal filling material.

  15. Do Stem Taper Microgrooves Influence Taper Corrosion in Total Hip Arthroplasty? A Matched Cohort Retrieval Study

    PubMed Central

    Arnholt, Christina M.; MacDonald, Daniel W.; Underwood, Richard; Guyer, Eric P.; Rimnac, Clare M.; Kurtz, Steven M.; Mont, Michael A.; Klein, Gregg; Lee, Gwo-Chin; Chen, Antonia F.; Hamlin, Brian; Cates, Harold; Malkani, Arthur; Kraay, Matthew

    2017-01-01

    Background Previous studies identified imprinting of the stem morphology onto the interior head bore, leading researchers to hypothesize an influence of taper topography on mechanically assisted crevice corrosion (MACC). The purpose of this study was to analyze whether micro-grooved stem tapers result in greater fretting corrosion damage than smooth stem tapers. Methods A matched cohort of 120 retrieved head-stem pairs from metal-on-polyethylene bearings was created controlling for implantation time, flexural rigidity, apparent length of engagement, and head size. There were two groups of 60 heads each, mated with either smooth or micro-grooved stem tapers. A high precision roundness machine was used to measure and categorize the surface morphology. Fretting corrosion damage at the head/neck junction was characterized using the Higgs-Goldberg scoring method. Fourteen of the most damaged heads, were analyzed for the maximum depth of material loss and focused ion beam (FIB) cross-sectioned to view oxide and base metal. Results Fretting corrosion damage was not different between the two cohorts at the femoral head (p = 0.14, Mann Whitney) or stem tapers (p = 0.35). There was no difference in the maximum depths of material loss between the cohorts (p = 0.71). Cross sectioning revealed contact damage, signs of micro-motion, and chromium rich oxide layers in both cohorts. Micro-groove imprinting did not appear to have a different effect on the fretting corrosion behavior. Conclusion The results of this matched cohort retrieval study do not support the hypothesis that taper surfaces with micro-grooved stems exhibit increased in vivo fretting corrosion damage or material release. PMID:28111124

  16. [Torque resistance of three different types of nickel-titanium rotary instruments].

    PubMed

    Sun, Wei; Hou, Ben-xiang

    2010-10-01

    To compare torsional fracture of three different types of nickel-titanium rotary instruments ProTaper, Hero642 and Mtwo by making a stimulate models in vitro. Through the establishment of model in vitro, compared the different time with 3 kinds of nickel titanium file in cutting-edge bound occurs, and to observe the section of fractured instruments by scanning electron microscope. The resistence to torque was different from three types of nickel titanium instruments. The time to fracture of Mtwo was significantly longer than ProTaper's and Hero642's, but ProTaper's and Hero642's had no significant difference. Three kinds cross-sectional design were different, a lot of toughness nests were seen in broken surface. Most of them were ductile fracture. Time to fracture was influenced by the quality disfigurement. The resistance to torque of Mtwo was better than ProTaper and Hero642. The lifespan was influenced by the design of cross-section. The quality disfigurement of the files reduced the resistance to flexual fatigue.

  17. Influence of nickel-titanium rotary systems with varying tapers on the biomechanical behaviour of maxillary first premolars under occlusal forces: a finite element analysis study.

    PubMed

    Askerbeyli Örs, S; Serper, A

    2018-05-01

    To evaluate the effect of three nickel-titanium (Ni-Ti) rotary systems with varying tapers on stress distribution and to analyse potential fracture patterns as well as the volume of fracture-susceptible regions in two-rooted maxillary premolars. The root canals of three single-rooted premolars were prepared with either HeroShaper (Micro-Mega, Besançon, France) to (size 30, .04 taper), Revo-S (Micro-Mega) to AS30 (size 30, .06 taper) or ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland) to F3 (size 30, .09 taper) Ni-Ti files. The three root canals were scanned using micro-computed tomography (μCT) (Skyscan 1174, Skyscan, Kontich, Belgium) and modelled according to the μCT data. An intact tooth model with a root length of 16 mm was also constructed based on μCT images of an extracted maxillary premolar with two roots. New models were constructed by replacing both of the original canals of the intact two-rooted premolar model with the modelled canals prepared with the HeroShaper, Revo-S or ProTaper Universal system. Occlusal forces of 200 N were applied in oblique and vertical directions. Finite element analysis was performed using Abaqus FEA software (Abaqus 6.14, ABAQUS Inc., Providence, RI, USA). Upon the application of oblique occlusal forces, the palatal external cervical root surface and the bifurcation (palatal side of the buccal root) in tooth models experienced the highest maximum principal (Pmax) stresses. The application of vertical forces resulted in minor Pmax stress values. Models prepared using the ProTaper system exhibited the highest Pmax stress values. The intact models exhibited the lowest Pmax stress values followed by the models prepared with the HeroShaper system. The differences in Pmax stress values amongst the different groups of models were mathematically minimal under normal occlusal forces. Rotary systems with varying tapers might predispose the root fracture on the palatal side of the buccal root and cervical palatal

  18. Femoral stem size mismatch in women undergoing total hip arthroplasty.

    PubMed

    Dundon, John M; Felberbaum, Dvorah Leah; Long, William J

    2018-06-01

    Total hip arthroplasty (THA) is a highly successful surgery with a high prevalence in women. Women have been noted to have smaller proximal femoral anatomy and decreased bone strength compared to males. The goal of our study was to define the size discrepancy in femoral stem implants between men and women using a metaphyseal fitting single taper stem. We retrospectively reviewed the THA's performed by a single surgeon over the previous two years. Data was extracted from operative reports regarding stem size, neck length and offset, and conversion to a different type of stem. This data was reviewed with confidence intervals and a t -test was performed for independent samples with a p < 0.05 being determined significant. We analyzed the data from 276 THA's performed (129 in men, and 147 in women). Women were noted to be associated with smaller stem sizes compared to men (37.67% in women, 6.11% in men), with 7.48% of women requiring conversion to a different type of implant. There was a significant difference in mean stem size (9.21 in men, 6.70 in women, p < 0.0001). Women also required reduced neck options significantly more often than men (38.97% in women, 9.29% in men, p < 0.0001). Review of femoral stem sizes reveals that current femoral stem sizing may not appropriately account for women and alternative stem options should be available if using a metaphyseal fitting single tapered stems. Future consideration should be given to more anatomic female sized femoral stems or alternative options should be available.

  19. The influence of simulated clinical use on the flexibility of rotary ProTaper Universal, K3 and EndoSequence nickel-titanium instruments.

    PubMed

    Viana, A C D; Pereira, E S J; Bahia, M G A; Buono, V T L

    2013-09-01

    To investigate the influence of cyclic flexural and torsional loading on the flexibility of ProTaper Universal, K3 and EndoSequence nickel-titanium instruments, in view of the hypothesis that these types of loading would decrease the flexibility of the selected NiTi rotary files. The instruments evaluated were S2 and F1 ProTaper Universal, sizes 20 and 25, .06 taper K3, and sizes 20 and 25, .06 taper EndoSequence. Flexibility was determined by 45° bending tests according to ISO 3630-1 specification. Values of the bending moment (MB ) obtained with new instruments were considered as the control group (CG). Bending tests were then conducted in instruments previously fatigued to one-fourth and three-fourths of their average fatigue life (fatigue groups, FG¼ and FG¾), as well as after cyclic torsional loading (torsional group, TG). Fatigue tests were carried out in a bench device that allowed the files to rotate freely inside an artificial canal with an angle of curvature of 45° and a radius of 5 mm. Cyclic torsional loading tests were performed that entailed rotating the instrument from zero angular deflection to 180° and then returning to zero applied torque in 20 cycles. Data were analysed using one-way analysis of variance at a significance level of 5%. Simulated clinical use by means of flexural fatigue tests did not affect the flexibility of the instruments, except for a significant increase in flexibility observed in a few instruments (P < 0.05). In addition, comparative statistical analyses between the values of MB measured in new instruments and after cyclic torsional loading showed no significant differences between them (P > 0.05). The flexibility of rotary ProTaper Universal, K3 and EndoSequence NiTi instruments, measured in bending tests, was not adversely affected by simulated clinical use in curved root canals. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  20. Development and Verification of Novel Porous Titanium Metaphyseal Cones for Revision Total Knee Arthroplasty.

    PubMed

    Faizan, Ahmad; Bhowmik-Stoker, Manoshi; Alipit, Vincent; Kirk, Amanda E; Krebs, Viktor E; Harwin, Steven F; Meneghini, R Michael

    2017-06-01

    Porous metaphyseal cones are widely used in revision knee arthroplasty. A new system of porous titanium metaphyseal cones has been designed based on the femoral and tibial morphology derived from a computed tomography-based anatomical database. The purpose of this study is to evaluate the initial mechanical stability of the new porous titanium revision cone system by measuring the micromotion under physiologic loading compared with a widely-used existing porous tantalum metaphyseal cone system. The new cones were designed to precisely fit the femoral and tibial anatomy, and 3D printing technology was used to manufacture these porous titanium cones. The stability of the new titanium cones and the widely-used tantalum cones were compared under physiologic loading conditions in bench top test model. The stability of the new titanium cones was either equivalent or better than the tantalum cones. The new titanium femoral cone construct had significantly less micromotion compared with the traditional femoral cone construct in 5 of the 12 directions measured (P < .05), whereas no statistical difference was found in 7 directions. The new porous titanium metaphyseal tibial cones demonstrated less micromotion in medial varus/valgus (P = .004) and posterior compressive micromotion (P = .002) compared with the traditional porous tantalum system. The findings of this biomechanical study demonstrate satisfactory mechanical stability of an anatomical-based porous titanium metaphyseal cone system for femoral and tibial bone loss as measured by micromotion under physiologic loading. The new cone design, in combination with instrumentation that facilitates surgical efficiency, is encouraging. Long-term clinical follow-up is warranted. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Stem geometry changes initial femoral fixation stability of a revised press-fit hip prosthesis: A finite element study.

    PubMed

    Russell, Robert D; Huo, Michael H; Rodrigues, Danieli C; Kosmopoulos, Victor

    2016-11-14

    Stable femoral fixation during uncemented total hip arthroplasty is critical to allow for subsequent osseointegration of the prosthesis. Varying stem designs provide surgeons with multiple options to gain femoral fixation. The purpose of this study was to compare the initial fixation stability of cylindrical and tapered stem implants using two different underreaming techniques (press-fit conditions) for revision total hip arthroplasty (THA). A finite element femur model was created from three-dimensional computed tomography images simulating a trabecular bone defect commonly observed in revision THA. Two 18-mm generic femoral hip implants were modeled using the same geometry, differing only in that one had a cylindrical stem and the other had a 2 degree tapered stem. Surgery was simulated using a 0.05-mm and 0.01-mm press-fit and tested with a physiologically relevant loading protocol. Mean contact pressure was influenced more by the surgical technique than by the stem geometry. The 0.05-mm press-fit condition resulted in the highest contact pressures for both the cylindrical (27.35 MPa) and tapered (20.99 MPa) stems. Changing the press-fit to 0.01-mm greatly decreased the contact pressure by 79.8% and 78.5% for the cylindrical (5.53 MPa) and tapered (4.52 MPa) models, respectively. The cylindrical stem geometry consistently showed less relative micromotion at all the cross-sections sampled as compared to the tapered stem regardless of press-fit condition. This finite element analysis study demonstrates that tapered stem results in lower average contact pressure and greater micromotion at the implant-bone interface than a cylindrical stem geometry. More studies are needed to establish how these different stem geometries perform in such non-ideal conditions encountered in revision THA cases where less bone stock is available.

  2. The shaping effects of three nickel-titanium rotary instruments in simulated S-shaped canals.

    PubMed

    Yoshimine, Y; Ono, M; Akamine, A

    2005-05-01

    The purpose of this study was to compare the shaping effects of three nickel-titanium rotary instruments, ProTaper, K3, and RaCe, with emphasis on canal transportation. Simulated canals with an S-shaped curvature in clear resin blocks were prepared with a torque-control, low-speed engine. Canals were prepared using the crown-down technique to the size of #30. Canal aberrations were assessed by comparing the pre- and postinstrumentation images under a stereomicroscope. ProTaper instruments caused greater widening of canals compared to K3 or RaCe. Furthermore, ProTaper files showed a tendency to ledge or zip formation at the end-point of preparation. These canal aberrations may be caused by ProTaper finishing files, which appear to be less flexible than other files of the same tip-size, because of their greater taper-size. These results suggest that nickel-titanium file systems including less tapered, more flexible instruments, like K3 and RaCe should be used in the apical preparation of canals with a complicated curvature.

  3. Evaluation of torque maintenance of abutment and cylinder screws with Morse taper implants.

    PubMed

    Ferreira, Mayara Barbosa; Delben, Juliana Aparecida; Barão, Valentim Adelino Ricardo; Faverani, Leonardo Perez; Dos Santos, Paulo Henrique; Assunção, Wirley Gonçalves

    2012-11-01

    The screw loosening of implant-supported prostheses is a common mechanical failure and is related to several factors as insertion torque and preload. The aim of this study was to evaluate the torque maintenance of retention screws of tapered abutments and cylinders of Morse taper implants submitted to retightening and detorque measurements. Two groups were obtained (n = 12): group I-tapered abutment connected to the implant with titanium retention screw and group II-cylinder with metallic base connected to tapered abutment with titanium retention screw. The detorque values were measured by an analogic torque gauge after 3 minutes of torque insertion. The detorque was measured 10 times for each retention screw of groups I and II, totalizing 120 detorque measurements in each group. Data were submitted to ANOVA and Fisher exact test (P < 0.05). Both groups presented reduced detorque value (P < 0.05) in comparison to the insertion torque in all measurement periods. There was a statistically significant difference (P < 0.05) between the detorque values of the first measurement and the other measurement periods for the abutment screw. However, there was no statistically significant difference (P > 0.05) for the detorque values of all measurement periods for the cylinder screw. In conclusion, the abutment and cylinder screws exhibited torque loss after insertion, which indicates the need for retightening during function of the implant-supported prostheses.

  4. Accuracy of femoral templating in reproducing anatomical femoral offset in total hip replacement.

    PubMed

    Davies, H; Foote, J; Spencer, R F

    2007-01-01

    Restoration of hip biomechanics is a crucial component of successful total hip replacement. Preoperative templating is recommended to ensure that the size and orientation of implants is optimised. We studied how closely natural femoral offset could be reproduced using the manufacturers' templates for 10 femoral stems in common use in the UK. A series of 23 consecutive preoperative radiographs from patients who had undergone unilateral total hip replacement for unilateral osteoarthritis of the hip was employed. The change in offset between the templated position of the best-fitting template and the anatomical centre of the hip was measured. The templates were then ranked according to their ability to reproduce the normal anatomical offset. The most accurate was the CPS-Plus (Root Mean Square Error 2.0 mm) followed in rank order by: C stem (2.16), CPT (2.40), Exeter (3.23), Stanmore (3.28), Charnley (3.65), Corail (3.72), ABG II (4.30), Furlong HAC (5.08) and Furlong modular (7.14). A similar pattern of results was achieved when the standard error of variability of offset was analysed. We observed a wide variation in the ability of the femoral prosthesis templates to reproduce normal femoral offset. This variation was independent of the seniority of the observer. The templates of modern polished tapered stems with high modularity were best able to reproduce femoral offset. The current move towards digitisation of X-rays may offer manufacturers an opportunity to improve template designs in certain instances, and to develop appropriate computer software.

  5. High wear resistance of femoral components coated with titanium nitride: a retrieval analysis.

    PubMed

    Fabry, Christian; Zietz, Carmen; Baumann, Axel; Ehall, Reinhard; Bader, Rainer

    2017-05-20

    The objective of this study was to evaluate the in vivo wear resistance of cobalt-chromium femoral components coated with titanium nitride (TiN). Our null hypothesis was that the surface damage and the thickness of the TiN coating do not correlate with the time in vivo. Twenty-five TiN-coated bicondylar femoral retrievals with a mean implantation period of 30.7 ± 11.7 months were subjected to an objective surface damage analysis with a semi-quantitative assessment method. A visual examination of scratches, indentations, notches and coating breakthroughs of the surfaces was performed. The roughness and the coating thickness of the TiN coating were evaluated in the main articulation regions. Narrow scratches and indentations in the range of low flexion angles on the retrieval surfaces were the most common modes of damage. There was no evidence of delamination on the articulation surface but rather at the bottom of isolated severe indentations or notches. An analysis of three retrievals revealed a coating breakthrough in the patellofemoral joint region, resulting from patella maltracking and a dislocation. The arithmetical mean roughness of the TiN surface slightly increased with the implantation period. In contrast, the maximum peak height of the roughness profile was reduced at the condyles of the retrieved components in comparison with new, unused surfaces. No significant association between the coating thickness and implantation period was determined. Moreover, the measured values were retained in the range of the initial coating thickness even after several years of in vivo service. As was demonstrated by the results of this study, the surface damage to the TiN coating did not deteriorate with the implantation period. The calculated damage scores and the measured coating thickness in particular both confirmed that the TiN coating provides low wear rates. Our findings support the use of wear-resistant TiN-coated components in total knee arthroplasty with the

  6. Designing an Optimized Novel Femoral Stem

    PubMed Central

    Babaniamansour, Parto; Ebrahimian-Hosseinabadi, Mehdi; Zargar-Kharazi, Anousheh

    2017-01-01

    Background: After total hip arthroplasty, there would be some problems for the patients. Implant loosening is one of the significant problems which results in thigh pain and even revision surgery. Difference between Young's modulus of bone-metal is the cause of stress shielding, atrophy, and subsequent implant loosening. Materials and Methods: In this paper, femoral stem stiffness is reduced by novel biomechanical and biomaterial design which includes using proper design parameters, coating it with porous surface, and modeling the sketch by the software. Parametric design of femoral stem is done on the basis of clinical reports. Results: Optimized model for femoral stem is proposed. Curved tapered stem with trapezoidal cross-section and particular neck and offset is designed. Fully porous surface is suggested. Moreover, Designed femoral stem analysis showed the Ti6Al4V stem which is covered with layer of 1.5 mm in thickness and 50% of porosity is as stiff as 77 GPa that is 30% less than the stem without any porosity. Porous surface of designed stem makes it fix biologically; thus, prosthesis loosening probability decreases. Conclusion: By optimizing femoral stem geometry (size and shape) and also making a porous surface, which had an intermediate stiffness of bone and implant, a more efficient hip joint prosthesis with more durability fixation was achieved due to better stress transmission from implant to the bone. PMID:28840118

  7. Assessment of a press-fit proximal femoral modular reconstruction implant (PFMR®) at 14.5 years. A 48-case series with a disturbing rate of implant fracture.

    PubMed

    Dumoulin, Q; Sabau, S; Goetzmann, T; Jacquot, A; Sirveaux, F; Mole, D; Roche, O

    2018-05-01

    The PFMR ® proximal femoral modular reconstruction implant (Protek, Sulzer Orthopedics, Switzerland) is a straight modular stem in sanded titanium with press-fit anchorage, intended to achieve spontaneous bone reconstruction following Wagner's principle. The aim of the present study was to analyze long-term clinical and radiological outcome. A single-center retrospective study included 48 PFMR stems implanted in 47 patients between 1998 and 2002. Results in this series were previously reported at 7 years' follow-up. Clinical assessment used PMA and Harris scores. Radiologic assessment focused on stem stability and osseointegration, and bone stock following Le Béguec. Twenty-three patients were seen at a mean 14.5 years' follow-up (13 deceased, 11 lost to follow-up), including 1 with bilateral implants, i.e., 24 stems. PMA and Harris scores, stem stability and osseointegration and bone stock were stable with respect to the 7-year findings. Radiology found 7 stem fractures in the Morse taper, i.e., in 29% of implants. Two of these cases required femoral implant replacement; 5 were asymptomatic. Long-term outcome for PFMR stems was clinically and radiologically satisfactory for the 16 patients free of mechanical complications. The Morse taper fracture rate was high, and higher than reported elsewhere. The usual risk factors for implant fracture were not found in the present series. The modular design of the press-fit revision implant is its weak point; monoblock implants should be used in patients with good life-expectancy. IV (retrospective study). Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  8. Biomechanical testing of bioabsorbable cannulated screws for slipped capital femoral epiphysis fixation.

    PubMed

    Kroeber, Markus W; Rovinsky, David; Haskell, Andrew; Heilmann, Moira; Llotz, Jeff; Otsuka, Norman

    2002-06-01

    This study compared cannulated 4.5-mm bioabsorbable screws made of self-reinforced poly-levolactic acid to cannulated 4.5-mm steel and titanium screws for resistance to shear stress and ability to generate compression in a polyurethane foam model of slipped capital femoral epiphysis fixation. The maximum shear stress resisted by the three screw types was similar (self-reinforced poly-levolactic acid 371 +/- 146 MPa, steel 442 +/- 43 MPa, and titanium 470 +/- 91 MPa). The maximum compression generated by both the self-reinforced poly-levolactic acid screw (68.5 +/- 3.3 N) and the steel screw (63.3 +/- 5.9 N) was greater than that for the titanium screw (3 +/- 1.4 N, P <.05). These data suggest cannulated self-reinforced poly-levolactic acid screws can be used in the treatment of slipped capital femoral epiphysis because of their sufficient biomechanical strength.

  9. Corrosion Damage and Wear Mechanisms in Long-Term Retrieved CoCr Femoral Components for Total Knee Arthroplasty.

    PubMed

    Arnholt, Christina M; MacDonald, Daniel W; Malkani, Arthur L; Klein, Gregg R; Rimnac, Clare M; Kurtz, Steven M; Kocagoz, Sevi B; Gilbert, Jeremy L

    2016-12-01

    Metal debris and ion release has raised concerns in joint arthroplasty. The purpose of this study was to characterize the sources of metallic ions and particulate debris released from long-term (in vivo >15 years) total knee arthroplasty femoral components. A total of 52 CoCr femoral condyles were identified as having been implanted for more than 15 years. The femoral components were examined for incidence of 5 types of damage (metal-on-metal wear due to historical polyethylene insert failure, mechanically assisted crevice corrosion at taper interfaces, cement interface corrosion, third-body abrasive wear, and inflammatory cell-induced corrosion [ICIC]). Third-body abrasive wear was evaluated using the Hood method for polyethylene components and a similar method quantifying surface damage of the femoral condyle was used. The total area damaged by ICIC was quantified using digital photogrammetry. Surface damage associated with corrosion and/or CoCr debris release was identified in 51 (98%) CoCr femoral components. Five types of damage were identified: 98% of femoral components exhibited third-body abrasive wear (mostly observed as scratching, n = 51/52), 29% of femoral components exhibited ICIC damage (n = 15/52), 41% exhibited cement interface damage (n = 11/27), 17% exhibited metal-on-metal wear after wear-through of the polyethylene insert (n = 9/52), and 50% of the modular femoral components exhibited mechanically assisted crevice corrosion taper damage (n = 2/4). The total ICIC-damaged area was an average of 0.11 ± 0.12 mm 2 (range: 0.01-0.46 mm 2 ). Although implant damage in total knee arthroplasty is typically reported with regard to the polyethylene insert, the results of this study demonstrate that abrasive and corrosive damage occurs on the CoCr femoral condyle in vivo. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Simple taper: Taper equations for the field forester

    Treesearch

    David R. Larsen

    2017-01-01

    "Simple taper" is set of linear equations that are based on stem taper rates; the intent is to provide taper equation functionality to field foresters. The equation parameters are two taper rates based on differences in diameter outside bark at two points on a tree. The simple taper equations are statistically equivalent to more complex equations. The linear...

  11. Comparison of effects of different screw materials in the triangle fixation of femoral neck fractures.

    PubMed

    Gok, Kadir; Inal, Sermet; Gok, Arif; Gulbandilar, Eyyup

    2017-05-01

    In this study, biomechanical behaviors of three different screw materials (stainless steel, titanium and cobalt-chromium) have analyzed to fix with triangle fixation under axial loading in femoral neck fracture and which material is best has been investigated. Point cloud obtained after scanning the human femoral model with the three dimensional (3D) scanner and this point cloud has been converted to 3D femoral model by Geomagic Studio software. Femoral neck fracture was modeled by SolidWorks software for only triangle configuration and computer-aided numerical analyses of three different materials have been carried out by AnsysWorkbench finite element analysis (FEA) software. The loading, boundary conditions and material properties have prepared for FEA and Von-Misses stress values on upper and lower proximity of the femur and screws have been calculated. At the end of numerical analyses, the best advantageous screw material has calculated as titanium because it creates minimum stress at the upper and lower proximity of the fracture line.

  12. Implication of femoral stem on performance of articular surface replacement (ASR) XL total hip arthroplasty.

    PubMed

    Cip, Johannes; von Strempel, Archibald; Bach, Christian; Luegmair, Matthias; Benesch, Thomas; Martin, Arno

    2014-11-01

    Taper junctions of large diameter metal-on-metal femoral heads and femoral stems were described as metal ion generator due to accelerated wear and corrosion. However, literature about the Articular Surface Replacement (ASR) total hip arthroplasty (THA) invariably deals with stems manufactured by DePuy Orthopedics (Warsaw, IN, USA). Nothing is known whether different stems with common 12/14 mm tapers affect failure rate or ion release. 99 ASR THA (88 patients) implanted with CoxaFit or ARGE Geradschaft stems (K-Implant, Hannover, Germany) were retrospectively analyzed. After a mean follow-up of 3.5 years revision rate was 24.5%, mostly due to adverse reaction to metal debris (ARMD). CT scan revealed component loosening in 10.3% and pseudotumoral lesions in 12.6%. Elevated ion concentrations (>7 μg/l) were found in 38.6%. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. [Deformation evaluation of ProTaper nickel-titanium rotary instruments in curved canals instrumentation in vitro].

    PubMed

    Yan, Hong; Ren, Min; Yin, Xing-Zhe; Zhao, Shu-Yan; Zhang, Cheng-Fei

    2008-04-01

    To evaluate the deformation of ProTaper rotary instruments using in root canals of different curvature in vitro. Extracted first mandibular molars were divided into two experimental groups according to the curvature of mesial buccal canals: group A with moderate curvature and group B with severe curvature. Only the mesial buccal canals of all these teeth were prepared with 6 sets of new ProTaper rotary instruments individually. Additionally, the control group was established with a set of new ProTaper rotary instruments. After finishing each canal preparation, the instruments accompanied by control were examined under the stereomicroscope by an inspector without knowing the group. If distortion, unwinding, abrasion or fracture occurred within one set of instruments, then the whole set was disposed. The sets without problems were in use until 30 times. After 5, 10, 20 times canal preparation, S1, F1 files without deformation under stereomicroscope were examined under scanning electron microscope (SEM). Deformation of ProTaper rotary instruments happened after 12 times in group A and after 7 times in group B. In these two experimental groups, microcracks were found increasing with the times of use under SEM in the instruments without deformation under stereomicroscope. The microcracks on tip of instruments were deep in the early use and became smoother after 10 times. Similar changes happened on knife-edge of instruments, and the microcracks extended over the edge after 20 times use. Root canals with severe curvature tend to damage ProTaper rotary instruments more frequently than moderately curved canals. ProTaper rotary instruments are appropriate to treat less than 7 root canals with severe curvature or 12 root canals with moderate curvature. Stereomicroscope is recommended to detect early damages on Ni-Ti rotary instruments, for preventing instruments fracture in clinic.

  14. Mechanical reduction of the intracanal Enterococcus faecalis population by Hyflex CM, K3XF, ProTaper Next, and two manual instrument systems: an in vitro comparative study.

    PubMed

    Tewari, Rajendra K; Ali, Sajid; Mishra, Surendra K; Kumar, Ashok; Andrabi, Syed Mukhtar-Un-Nisar; Zoya, Asma; Alam, Sharique

    2016-05-01

    In the present study, the effectiveness of three rotary and two manual nickel titanium instrument systems on mechanical reduction of the intracanal Enterococcus faecalis population was evaluated. Mandibular premolars with straight roots were selected. Teeth were decoronated and instrumented until 20 K file and irrigated with physiological saline. After sterilization by ethylene oxide gas, root canals were inoculated with Enterococcus faecalis. The specimens were randomly divided into five groups for canal instrumentation: Manual Nitiflex and Hero Shaper nickel titanium files, and rotary Hyflex CM, ProTaper Next, and K3XF nickel titanium files. Intracanal bacterial sampling was done before and after instrumentation. After serial dilution, samples were plated onto the Mitis Salivarius agar. The c.f.u. grown were counted, and log10 transformation was calculated. All instrumentation systems significantly reduced the intracanal bacterial population after root canal preparation. ProTaper Next was found to be significantly more effective than Hyflex CM and manual Nitiflex and Hero Shaper. However, ProTaper Next showed no significant difference with K3XF. Canal instrumentation by all the file systems significantly reduced the intracanal Enterococcus faecalis counts. ProTaper Next was found to be most effective in reducing the number of bacteria than other rotary or hand instruments. © 2014 Wiley Publishing Asia Pty Ltd.

  15. The effect of screw taper on interference fit during load to failure at the soft tissue/bone interface.

    PubMed

    Mann, Charles J; Costi, John J; Stanley, Richard M; Dobson, Peter J

    2005-10-01

    The effect of screw geometry on the pullout strength of an anterior cruciate ligament reconstruction is well documented. The effect of a truly tapered screw has not been previously investigated. Thirty bovine knees in right and left knee pairs were collected. Superficial digital flexors from the hind legs of sheep were harvested to form a quadruple tendon graft. For each knee pair, one tendon graft was fixed using a tapered screw (n=15) and the other with a non-tapered screw (n=15). Interference screws were manufactured from stainless steel, and apart from the tapered or non-tapered profile were identical. The screws were inserted into a tibial tunnel already containing the tendon graft. The interference fit was tested by extensile load to failure tests. The insertion torque of the screws and first sign of load to failure (by pullout) of the interference fit were recorded. Results were analysed using paired t-tests. The results indicated that tapered screws have significantly higher resistance to interference failure (p=0.007) and insertion torque (p<0.001) than non-tapered screws. The improved biomechanical performance of tapered screws demonstrated in this study may translate into superior clinical results, particularly at the tibial attachment of hamstring anterior cruciate ligament reconstruction, and also of hamstring fixation to the medial femoral condyle for patella instability.

  16. The Influence of Contamination and Cleaning on the Strength of Modular Head Taper Fixation in Total Hip Arthroplasty.

    PubMed

    Krull, Annika; Morlock, Michael M; Bishop, Nicholas E

    2017-10-01

    Intraoperative interface contamination of modular head-stem taper junctions of hip implants can lead to poor fixation strength, causing fretting and crevice corrosion or even stem taper fracture. Careful cleaning before assembly should help to reduce these problems. The purpose of this study was to determine the effect of cleaning (with and without drying) contaminated taper interfaces on the taper fixation strength. Metal or ceramic heads were impacted onto titanium alloy stem tapers with cleaned or contaminated (fat or saline solution) interfaces. The same procedure was performed after cleaning and drying the contaminated interfaces. Pull-off force was used to determine the influence of contamination and cleaning on the taper strength. Pull-off forces after contamination with fat were significantly lower than those for uncontaminated interfaces for both head materials. Pull-off forces after application of saline solution were not significantly different from those for uncontaminated tapers. However, a large variation in taper strength was observed, pull-off forces for cleaned and dried tapers were similar to those for uncontaminated tapers for both head materials. Intraoperative contamination of taper interfaces may be difficult to detect but has a major influence on taper fixation strength. Cleaning of the stem taper with saline solution and drying with gauze directly before assembly allows the taper strength of the pristine components to be achieved. Not drying the taper results in a large variation in pull-off forces, emphasizing that drying is essential for sufficient and reproducible fixation strength. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. [Shaping ability of two nickel-titanium rotary systems in simulated S-shaped canals].

    PubMed

    Luo, Hong-xia; Huang, Ding-ming; Zhang, Fu-hua; Tan, Hong; Zhou, Xue-dong

    2008-01-01

    To evaluate the shaping ability of two nickel-titanium rotary systems (ProTaper and Hero642) in simulated S-shaped canals. Thirty simulated S-shaped canals were randomly divided into three groups and prepared by ProTaper, Hero642, ProTaper combined with Hero642 respectively. All the canals were scanned before and after instrumentation, and the amount of material removed in the inner and outer wall and the canal width after instrumentation were measured with a computer image analysis program. There was significant difference in the amount of material removed at the inner side of apical curvature and outer side of apex between ProTaper combined with Hero642 and ProTaper files (P < 0.05) at the same tip size. The inner and outer wall of the canals were evenly prepared by ProTaper combined with Hero642, and the taper of canals were better than those prepared by Hero642. ProTaper combined with Hero 642 had better shaping ability to maintain the original shape and could create good taper canals in the simulated S-shaped canal model.

  18. Fatigue fracture of a proximally modular, distally tapered fluted implant with diaphyseal fixation.

    PubMed

    Buttaro, Martín A; Mayor, Michael B; Van Citters, Douglas; Piccaluga, Francisco

    2007-08-01

    We report and analyze the causes of a fracture in a proximally modular, distally tapered fluted MP stem in a 48-year-old woman (168 cm, 67 kg) with severe proximal bone deficiency. Evidence of fatigue failure with striations initiated laterally was observed in the laser etching of the tensile aspect of the prosthesis. However, metallurgical analysis suggested that laser engraving did not alter the microstructure of the stem. Stress due to the absence of proximal femoral bone support may have been sufficiently high to put this particular stem at risk for fatigue fracture. This important complication should be addressed when choosing this therapeutic option in cases with substantial proximal femoral bone loss. Strut allograft support should be recommended in such cases.

  19. Quantification of the Contact Area at the Head-Stem Taper Interface of Modular Hip Prostheses

    PubMed Central

    Witt, Florian; Gührs, Julian; Morlock, Michael M.; Bishop, Nicholas E.

    2015-01-01

    Corrosion of modular taper junctions of hip implants may be associated with clinical failure. Taper design parameters, as well as the intraoperatively applied assembly forces, have been proposed to affect corrosion. Fretting corrosion is related to relative interface shear motion and fluid ingress, which may vary with contact force and area. It was hypothesised in this study that assembly forces modify the extent and distribution of the surface contact area at the taper interface between a cobalt chrome head and titanium stem taper with a standard threaded surface profile. Local abrasion of a thin gold coating applied to the stem taper prior to assembly was used to determine the contact area after disassembly. Profilometry was then used to assess permanent deformation of the stem taper surface profile. With increasing assembly force (500 N, 2000 N, 4000 N and 8000 N) the number of stem taper surface profile ridges in contact with the head taper was found to increase (9.2±9.3%, 65.4±10.8%, 92.8±6.0% and 100%) and the overall taper area in contact was also found to increase (0.6±0.7%, 5.5±1.0%, 9.9±1.1% and 16.1±0.9%). Contact was inconsistently distributed over the length of the taper. An increase in plastic radial deformation of the surface ridges (-0.05±0.14 μm, 0.1±0.14 μm, 0.21±0.22 μm and 0.96±0.25 μm) was also observed with increasing assembly force. The limited contact of the taper surface ridges at lower assembly forces may influence corrosion rates, suggesting that the magnitude of the assembly force may affect clinical outcome. The method presented provides a simple and practical assessment of the contact area at the taper interface. PMID:26280914

  20. Quantification of the Contact Area at the Head-Stem Taper Interface of Modular Hip Prostheses.

    PubMed

    Witt, Florian; Gührs, Julian; Morlock, Michael M; Bishop, Nicholas E

    2015-01-01

    Corrosion of modular taper junctions of hip implants may be associated with clinical failure. Taper design parameters, as well as the intraoperatively applied assembly forces, have been proposed to affect corrosion. Fretting corrosion is related to relative interface shear motion and fluid ingress, which may vary with contact force and area. It was hypothesised in this study that assembly forces modify the extent and distribution of the surface contact area at the taper interface between a cobalt chrome head and titanium stem taper with a standard threaded surface profile. Local abrasion of a thin gold coating applied to the stem taper prior to assembly was used to determine the contact area after disassembly. Profilometry was then used to assess permanent deformation of the stem taper surface profile. With increasing assembly force (500 N, 2000 N, 4000 N and 8000 N) the number of stem taper surface profile ridges in contact with the head taper was found to increase (9.2±9.3%, 65.4±10.8%, 92.8±6.0% and 100%) and the overall taper area in contact was also found to increase (0.6±0.7%, 5.5±1.0%, 9.9±1.1% and 16.1±0.9%). Contact was inconsistently distributed over the length of the taper. An increase in plastic radial deformation of the surface ridges (-0.05±0.14 μm, 0.1±0.14 μm, 0.21±0.22 μm and 0.96±0.25 μm) was also observed with increasing assembly force. The limited contact of the taper surface ridges at lower assembly forces may influence corrosion rates, suggesting that the magnitude of the assembly force may affect clinical outcome. The method presented provides a simple and practical assessment of the contact area at the taper interface.

  1. Bending stiffness, torsional stability, and insertion force of cementless femoral stems.

    PubMed

    Incavo, S J; Johnson, C C; Churchill, D L; Beynnon, B D

    2001-04-01

    In cementless total hip arthroplasty, increased femoral stem flexibility and decreased fracture propensity are desirable characteristics. The slotting and tapering of the stem have been introduced to achieve this. These features should not, however, be allowed to interfere with the ability of the distal stem to provide initial mechanical stability, especially under rotation. This study was done to investigate the ability of slotted and tapered stem designs to reduce stiffness and insertion force while still maintaining adequate torsional strength. The torsional strength, maximum insertion force, and insertional work of straight, slotted, and taper stems were measured by inserting each type into rigid polyurethane foam and torque testing to failure. Bending stiffness of each stem design was calculated using numerical methods. When compared to a straight stem, a unislot stem has similar torsional strength, maximum insertional force, and work of insertion. The bending stiffness is decreased by 19% to 82% depending on the bending direction. A trislot design decreased torque strength by 29%, maximal insertion force by 36%, and work by 11%. Bending stiffness was decreased by 74% and was not dependent on bending direction. A 0.5-mm taper decreased torque strength by 11% and insertional work by 14%. No difference was seen in maximum insertional force. We conclude that the design features studied (slots and taper) are effective in decreasing stem stiffness and reducing fracture propensity.

  2. High Sensitivity Refractometer Based on TiO₂-Coated Adiabatic Tapered Optical Fiber via ALD Technology.

    PubMed

    Zhu, Shan; Pang, Fufei; Huang, Sujuan; Zou, Fang; Guo, Qiang; Wen, Jianxiang; Wang, Tingyun

    2016-08-15

    Atomic layer deposition (ALD) technology is introduced to fabricate a high sensitivity refractometer based on an adiabatic tapered optical fiber. Different thicknesses of titanium dioxide (TiO₂) nanofilm were coated around the tapered fiber precisely and uniformly under different deposition cycles. Attributed to the higher refractive index of the TiO₂ nanofilm compared to that of silica, an asymmetric Fabry-Perot (F-P) resonator could be constructed along the fiber taper. The central wavelength of the F-P resonator could be controlled by adjusting the thickness of the TiO₂ nanofilm. Such a F-P resonator is sensitive to changes in the surrounding refractive index (SRI), which is utilized to realize a high sensitivity refractometer. The refractometer developed by depositing 50.9-nm-thickness TiO₂ on the tapered fiber shows SRI sensitivity as high as 7096 nm/RIU in the SRI range of 1.3373-1.3500. Due to TiO₂'s advantages of high refractive index, lack of toxicity, and good biocompatibility, this refractometer is expected to have wide applications in the biochemical sensing field.

  3. Biologically synthesized titanium oxide nanostructures combined with morphogenetic protein as wound healing agent in the femoral fracture after surgery.

    PubMed

    Zhang, Yushu; Zhang, Chuanlian; Liu, Kemiao; Zhu, Xia; Liu, Fang; Ge, Xiaofen

    2018-05-01

    The aim of the present study is to develop novel approach for the green synthesis of titanium oxide nanoparticles (TiO 2 NPs) using Eichhornia crassipes extract and calcined at different temperatures for evaluate the wound healing activity in the femoral fracture. The synthesized TiO 2 are formed different (plate and rod-like) nanostructures at various calcination temperatures. These samples were characterized by X-ray diffraction (XRD), Fourier transform-infrared spectroscopy (FTIR), Field emission scanning electron microscope (FE-SEM) and transmission electron microscope (TEM). Microscopic studies of TiO 2 NPs revealed that the synthesized TiO 2 NPs are formed well-defined rod-like structures at 400 °C with size ranged from 200 nm to 500 nm. The characterized plate and rod-like TiO 2 NPs are combined with human morphogenetic protein (HbMP) to improving its wound healing activity and osteoblast properties on femoral fractures. The biocompatibility was tested by using human bone marrow mesenchymal stem cells (BMSC) cells and antibacterial efficacy analyzed using human pathogenica bacteria Staphylococcus aureus and Escherichia coli through agar well diffusion assay. The green synthesized rod-like TiO 2 NPs combined with HbMP has been exhibited effective bone fusion behaviors with biomechanical properties and also improved antibacterial activity against pathogenic bacteria. From this study results, it is suggested that green synthesized TiO 2 NPs could be used effectively in biomedical application. Copyright © 2018. Published by Elsevier B.V.

  4. Comparison of the fracture resistance of dental implants with different abutment taper angles.

    PubMed

    Wang, Kun; Geng, Jianping; Jones, David; Xu, Wei

    2016-06-01

    To investigate the effects of abutment taper angles on the fracture strength of dental implants with TIS (taper integrated screwed-in) connection. Thirty prototype cylindrical titanium alloy 5.0mm-diameter dental implants with different TIS-connection designs were divided into six groups and tested for their fracture strength, using a universal testing machine. These groups consisted of combinations of 3.5 and 4.0 mm abutment diameter, each with taper angles of 6°, 8° or 10°. 3-Dimensional finite element analysis (FEA) was also used to analyze stress states at implant-abutment connection areas. In general, the mechanical tests found an increasing trend of implant fracture forces as the taper angle enlarged. When the abutment diameter was 3.5 mm, the mean fracture forces for 8° and 10° taper groups were 1638.9 N ± 20.3 and 1577.1 N ± 103.2, respectively, both larger than that for the 6° taper group of 1475.0 N ± 24.4, with the largest increasing rate of 11.1%. Furthermore, the difference between 8° and 6° taper groups was significant, based on Tamhane's multiple comparison test (P<0.05). In 4.0 mm-diameter abutment groups, as the taper angle was enlarged from 6° to 8° and 10°, the mean fracture value was increased from 1066.7 N ± 56.1 to 1241.4 N ± 6.4 and 1419.3 N ± 20.0, with the largest increasing rate of 33.1%, and the differences among the three groups were significant (P<0.05). The FEA results showed that stress values varied in implants with different abutment taper angles and supported the findings of the static tests. In conclusion, increases of the abutment taper angle could significantly increase implant fracture resistance in most cases established in the study, which is due to the increased implant wall thickness in the connection part resulting from the taper angle enlargement. The increasing effects were notable when a thin implant wall was present to accommodate wide abutments. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Cyclic fatigue of ProTaper instruments.

    PubMed

    Lopes, Hélio Pereira; Moreira, Edson Jorge Lima; Elias, Carlos Nelson; de Almeida, Renata Andriola; Neves, Mônica Schultz

    2007-01-01

    The present work evaluated the influence of the curved segment length of artificial root canals (the arc) and the number of cycles necessary to fracture engine-driven nickel-titanium endodontic instruments. ProTaper F3 25-mm files at 250 rpm were used in two artificial canals. The artificial canals were made of stainless steel with an inner diameter of 1.04 mm, a total length of 20 mm, and arc on the ends with a radius of curvature of 6 mm. The arc length of the first tube measured 9.4 mm, and the straight part measured 10.6 mm. The second tube was 14.1 mm long, and the straight part measured 5.9 mm. We determined the fracture surface distances and the number of cycles necessary to induce fatigue fracture in the ProTaper F3 instruments. The fracture surfaces and the helical shaft of the instruments were investigated using a scanning electron microscope. The results indicated that the required number of cycles to cause a fracture was influenced by the canal arc length, the morphology of the fractured surface presented ductile characteristics, and plastic deformation in the helical shaft of the fractured instruments did not occur.

  6. Evaluation of debris extruded apically during the removal of root canal filling material using ProTaper, D-RaCe, and R-Endo rotary nickel-titanium retreatment instruments and hand files.

    PubMed

    Topçuoğlu, Hüseyin Sinan; Aktı, Ahmet; Tuncay, Öznur; Dinçer, Asiye Nur; Düzgün, Salih; Topçuoğlu, Gamze

    2014-12-01

    The aim of this study was to evaluate the amount of debris extruded apically during the removal of root canal filling material using ProTaper (Dentsply Maillefer, Ballaigues, Switzerland), D-RaCe (FKG Dentaire, La Chaux-de-Fonds, Switzerland), and R-Endo (Micro-Mega, Besançon, France) nickel-titanium (NiTi) rotary retreatment instruments and hand files. Sixty extracted single-rooted mandibular premolar teeth were prepared with K-files and filled with gutta-percha and AH Plus sealer (Dentsply DeTrey, Konstanz, Germany). The teeth were then randomly assigned to 4 groups (n = 15 for each group) for retreatment. The removal of canal filling material was performed as follows: hand files, ProTaper, D-RaCe, and R-Endo retreatment instruments. Debris extruded apically during the removal of canal filling material was collected into preweighed Eppendorf tubes. The tubes were then stored in an incubator at 70°C for 5 days. The weight of the dry extruded debris was established by subtracting the preretreatment and postretreatment weight of the Eppendorf tubes for each group. The data obtained were analyzed using 1-way analysis of variance and Tukey post hoc tests. All retreatment techniques caused the apical extrusion of debris. Hand files produced significantly more debris when compared with ProTaper, D-RaCe, and R-Endo rotary systems (P < .05). There was no statistical difference between the ProTaper, D-RaCe, and R-Endo retreatment systems (P > .05). The findings showed that during the removal of root canal filling material, rotary NiTi retreatment instruments used in this study caused less apical extrusion of debris compared with hand files. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. Mechanical properties of ProTaper Gold nickel-titanium rotary instruments.

    PubMed

    Elnaghy, A M; Elsaka, S E

    2016-11-01

    To evaluate and compare the resistance to cyclic fatigue and torsional stress, flexibility and surface microhardness of ProTaper Gold (PTG; Dentsply, Tulsa Dental Specialties, Tulsa, OK, USA) system with ProTaper Universal (PTU; Dentsply Maillefer, Ballaigues, Switzerland). PTG and PTU instruments were rotated in simulated canals and the number of cycles to failure was recorded to assess their cyclic fatigue resistance. Torsional strength was measured using a torsiometer after fixing firmly the apical 3 mm of the instrument. A scanning electron microscope was used to characterize the topographic features of the fracture surfaces of the broken instruments. The instruments were tested for bending resistance using cantilever-bending test. Vickers microhardness was measured on the cross section of instruments with 300 g load and 15 s dwell time. Data were analysed statistically using independent t-tests. Statistical significance was set at P < 0.05. PTG instruments had a significantly higher resistance to cyclic fatigue and flexibility than PTU (P < 0.001). The fractured cross-sectional surfaces revealed typical features of cyclic fractures, including crack origins, fatigue zones and overload fast fracture zones. On the other hand, PTU instruments were associated with higher resistance to torsional stress and microhardness than PTG instruments (P < 0.001). After torsional tests, the fractured cross-sectional surfaces revealed skewed dimples near the centre of the fracture surfaces and circular abrasion streaks. The PTG instrument had improved resistance to cyclic fatigue and flexibility compared with PTU. PTU instruments had improved resistance to torsional stress and microhardness compared with PTG. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  8. Comparative evaluation of dentinal crack formation after root canal preparation using ProTaper Next, OneShape, and Hyflex EDM

    PubMed Central

    Das, Sanjib; Pradhan, Prasanti Kumari; Lata, S.; Sinha, Sachidananda Prasad

    2018-01-01

    Introduction: The purpose of this study was to compare the incidence of dentinal crack formation after root canal preparation using ProTaper Next, OneShape, and Hyflex electrodischarge machining (HEDM). Materials and Methods: A total of 75 extracted mandibular premolars were selected. The root canals were instrumented using ProTaper Next, OneShape, and HEDM rotary files. All roots were horizontally sectioned at 3, 6, and 9 mm from apex with slow-speed saw under water cooling. The sections were observed under a stereomicroscope at ×25 to determine the absence or presence of crack. Data were analyzed using post hoc test and one-way ANOVA. Results: ProTaper Next and HEDM produced significantly less cracks than OneShape. Conclusion: Within the limitation of this in vitro study, it can be concluded that nickel–titanium instruments may cause cracks on the root surface. ProTaper Next and HEDM tend to produce less number of cracks as compared to OneShape. PMID:29674816

  9. New type of hip arthroplasty failure related to modular femoral components: breakage at the neck-stem junction.

    PubMed

    Wodecki, P; Sabbah, D; Kermarrec, G; Semaan, I

    2013-10-01

    Total hip replacements (THR) with modular femoral components (stem-neck interface) make it possible to adapt to extramedullary femoral parameters (anteversion, offset, and length) theoretically improving muscle function and stability. Nevertheless, adding a new interface has its disadvantages: reduced mechanical resistance, fretting corrosion and material fatigue fracture. We report the case of a femoral stem fracture of the female part of the component where the modular morse taper of the neck is inserted. An extended trochanteric osteotomy was necessary during revision surgery because the femoral stump could not be grasped for extraction, so that a long stem had to be used. In this case, the patient had the usual risk factors for modular neck failure: he was an active overweight male patient with a long varus neck. This report shows that the female part of the stem of a small femoral component may also be at increased failure risk and should be added to the list of risk factors. To our knowledge, this is the first reported case of this type of failure. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  10. In Vitro Comparison of Cyclic Fatigue Resistance of ProTaper Next, HyFlex CM, OneShape, and ProTaper Universal Instruments in a Canal with a Double Curvature.

    PubMed

    Topçuoğlu, Hüseyin Sinan; Topçuoğlu, Gamze; Akti, Ahmet; Düzgün, Salih

    2016-06-01

    The aim of this study was to compare the resistance to cyclic fatigue of ProTaper Next X2 (PTN X2; size 25, 0.06 taper), Hyflex CM (HCM; size 25, 0.06 taper), OneShape (OS; size 25, 0.06 taper), and ProTaper Universal F2 (PTU F2; size 25, 0.08 taper) nickel-titanium files in an artificial root canal with a double (S-shaped) curvature. A total of 160 new PTN X2, OS, HCM, and PTU F2 files were tested in an artificial stainless steel canal with a double curvature. Forty files from each system were rotated until fracture to calculate the number of cycles to failure. The length of each fractured fragment was recorded. Data were analyzed by using one-way analysis of variance and Tukey post hoc tests. The resistance to cyclic fatigue of the PTN X2 and HCM instruments was significantly greater than the OS and PTU F2 instruments in the apical curvature (P < .05). There was no statistical difference in the cyclic fatigue resistance of the PTN X2 and HCM instruments in the apical curvature (P > .05). In addition, there was no statistical difference between the OS and PTU F2 instruments in the apical curvature (P > .05). PTN X2, OS, HCM, and PTU F2 instruments showed similar cyclic fatigue resistance values in the coronal curvature (P > .05). This study showed that PTN X2 and HCM instruments exhibit greater resistance to cyclic fatigue than OS and PTU F2 instruments in the apical curvature of an artificial canal with a double curvature. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  11. Experimental Measurement of the Static Coefficient of Friction at the Ti-Ti Taper Connection in Total Hip Arthroplasty.

    PubMed

    Bitter, T; Khan, I; Marriott, T; Schreurs, B W; Verdonschot, N; Janssen, D

    2016-03-01

    The modular taper junction in total hip replacements has been implicated as a possible source of wear. The finite-element (FE) method can be used to study the wear potential at the taper junction. For such simulations it is important to implement representative contact parameters, in order to achieve accurate results. One of the main parameters in FE simulations is the coefficient of friction. However, in current literature, there is quite a wide spread in coefficient of friction values (0.15 - 0.8), which has a significant effect on the outcome of the FE simulations. Therefore, to obtain more accurate results, one should use a coefficient of friction that is determined for the specific material couple being analyzed. In this study, the static coefficient of friction was determined for two types of titanium-on-titanium stem-adaptor couples, using actual cut-outs of the final implants, to ensure that the coefficient of friction was determined consistently for the actual implant material and surface finish characteristics. Two types of tapers were examined, Biomet type-1 and 12/14, where type-1 has a polished surface finish and the 12/14 is a microgrooved system. We found static coefficients of friction of 0.19 and 0.29 for the 12/14 and type-1 stem-adaptor couples, respectively.

  12. Mechanics and complications of reverse shoulder arthroplasty: morse taper failure analysis and prospective rectification

    NASA Astrophysics Data System (ADS)

    Hoskin, HLD; Furie, E.; Collins, W.; Ganey, TM; Schlatterer, DR

    2017-05-01

    Since Sir John Charnley began his monumental hip arthroplasty work in 1958, clinical researchers have been incrementally improving longevity and functionality of total joint systems, although implant failure occurs on occasion. The purpose of this study is to report the fracture of the humeral tray Morse taper of a reverse total shoulder system (RTSS), which to date has not been reported with metallurgic analysis for any RTSS. There was no reported antecedent fall, motor vehicle collision, or other traumatic event prior to implant fracture in this case. Analysis was performed on the retrieved failed implant by Scanning Electron Microscopy (SEM) and Electron Dispersion Spectroscopy (EDS) in an attempt to determine the failure method, as well as to offer improvements for future implants. At the time of revision surgery all explants were retained from the left shoulder of a 61-year old male who underwent a non-complicated RTSS 4 years prior. The explants, particularly the cracked humeral tray, were processed as required for SEM and EDS. Analysis was performed on the failure sites in order to determine the chemical composition of the different parts of the implant, discover the chemical composition of the filler metal used during the electron beam welding process, and to detect any foreign elements that could suggest corrosion or other evidence of failure etiology. Gross visual inspection of all explants revealed that implant failure was a result of dissociation of the taper from the humeral tray at the weld, leaving the Morse taper embedded in the humeral stem while the tray floated freely in the patient’s shoulder. SEM further confirmed the jagged edges noted grossly at the weld fracture site, both suggesting failure due to torsional forces. EDS detected elevated levels of carbon and oxygen at the fracture site on the taper only and not on the humeral tray. In order to determine the origin of the high levels of C and O, it was considered that in titanium alloys, C

  13. High Sensitivity Refractometer Based on TiO2-Coated Adiabatic Tapered Optical Fiber via ALD Technology

    PubMed Central

    Zhu, Shan; Pang, Fufei; Huang, Sujuan; Zou, Fang; Guo, Qiang; Wen, Jianxiang; Wang, Tingyun

    2016-01-01

    Atomic layer deposition (ALD) technology is introduced to fabricate a high sensitivity refractometer based on an adiabatic tapered optical fiber. Different thicknesses of titanium dioxide (TiO2) nanofilm were coated around the tapered fiber precisely and uniformly under different deposition cycles. Attributed to the higher refractive index of the TiO2 nanofilm compared to that of silica, an asymmetric Fabry–Perot (F-P) resonator could be constructed along the fiber taper. The central wavelength of the F-P resonator could be controlled by adjusting the thickness of the TiO2 nanofilm. Such a F-P resonator is sensitive to changes in the surrounding refractive index (SRI), which is utilized to realize a high sensitivity refractometer. The refractometer developed by depositing 50.9-nm-thickness TiO2 on the tapered fiber shows SRI sensitivity as high as 7096 nm/RIU in the SRI range of 1.3373–1.3500. Due to TiO2’s advantages of high refractive index, lack of toxicity, and good biocompatibility, this refractometer is expected to have wide applications in the biochemical sensing field. PMID:27537885

  14. Parabolic tapers for overmoded waveguides

    DOEpatents

    Doane, J.L.

    1983-11-25

    A waveguide taper with a parabolic profile, in which the distance along the taper axis varies as the square of the tapered dimension, provides less mode conversion than equal length linear tapers and is easier to fabricate than other non-linear tapers.

  15. Assessment of apically extruded debris produced by the single-file ProTaper F2 technique under reciprocating movement.

    PubMed

    De-Deus, Gustavo; Brandão, Maria Claudia; Barino, Bianca; Di Giorgi, Karina; Fidel, Rivail Antonio Sergio; Luna, Aderval Severino

    2010-09-01

    This study was designed to quantitatively evaluate the amount of dentin debris extruded from the apical foramen by comparing the conventional sequence of the ProTaper Universal nickel-titanium (NiTi) files with the single-file ProTaper F2 technique. Thirty mesial roots of lower molars were selected, and the use of different instrumentation techniques resulted in 3 groups (n=10 each). In G1, a crown-down hand-file technique was used, and in G2 conventional ProTaper Universal technique was used. In G3, ProTaper F2 file was used in a reciprocating motion. The apical finish preparation was equivalent to ISO size 25. An apparatus was used to evaluate the apically extruded debris. Statistical analysis was performed using 1-way analysis of variance and Tukey multiple comparisons. No significant difference was found in the amount of the debris extruded between the conventional sequence of the ProTaper Universal NiTi files and the single-file ProTaper F2 technique (P>.05). In contrast, the hand instrumentation group extruded significantly more debris than both NiTi groups (P<.05). The present results yielded favorable input for the F2 single-file technique in terms of apically extruded debris, inasmuch as it is the most simple and cost-effective instrumentation approach. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  16. Evaluation of the incidence of microcracks caused by Mtwo and ProTaper Next rotary file systems versus the self-adjusting file: A scanning electron microscopic study

    PubMed Central

    Saha, Suparna Ganguly; Vijaywargiya, Neelam; Saxena, Divya; Saha, Mainak Kanti; Bharadwaj, Anuj; Dubey, Sandeep

    2017-01-01

    Introduction: To evaluate the incidence of microcrack formation canal preparation with two rotary nickel–titanium systems Mtwo and ProTaper Next along with the self-adjusting file system. Materials and Methods: One hundred and twenty mandibular premolar teeth were selected. Standardized access cavities were prepared and the canals were manually prepared up to size 20 after coronal preflaring. The teeth were divided into three experimental groups and one control group (n = 30). Group 1: The canals were prepared using Mtwo rotary files. Group 2: The canals were prepared with ProTaper Next files. Group 3: The canals were prepared with self-adjusting files. Group 4: The canals were unprepared and used as a control. The roots were sectioned horizontally 3, 6, and 9 mm from the apex and examined under a scanning electron microscope to check for the presence of microcracks. The Pearson's Chi-square test was applied. Results: The highest incidence of microcracks were associated with the ProTaper Next group, 80% (P = 0.00), followed by the Mtwo group, 70% (P = 0.000), and the least number of microcracks was noted in the self-adjusting file group, 10% (P = 0.068). No significant difference was found between the ProTaper Next and Mtwo groups (P = 0.368) while a significant difference was observed between the ProTaper Next and self-adjusting file groups (P = 0.000) as well as the Mtwo and self-adjusting file groups (P = 0.000). Conclusion: All nickel–titanium rotary instrument systems were associated with microcracks. However, the self-adjusting file system had significantly fewer microcracks when compared with the Mtwo and ProTaper Next. PMID:29386786

  17. Evaluation of the incidence of microcracks caused by Mtwo and ProTaper Next rotary file systems versus the self-adjusting file: A scanning electron microscopic study.

    PubMed

    Saha, Suparna Ganguly; Vijaywargiya, Neelam; Saxena, Divya; Saha, Mainak Kanti; Bharadwaj, Anuj; Dubey, Sandeep

    2017-01-01

    To evaluate the incidence of microcrack formation canal preparation with two rotary nickel-titanium systems Mtwo and ProTaper Next along with the self-adjusting file system. One hundred and twenty mandibular premolar teeth were selected. Standardized access cavities were prepared and the canals were manually prepared up to size 20 after coronal preflaring. The teeth were divided into three experimental groups and one control group ( n = 30). Group 1: The canals were prepared using Mtwo rotary files. Group 2: The canals were prepared with ProTaper Next files. Group 3: The canals were prepared with self-adjusting files. Group 4: The canals were unprepared and used as a control. The roots were sectioned horizontally 3, 6, and 9 mm from the apex and examined under a scanning electron microscope to check for the presence of microcracks. The Pearson's Chi-square test was applied. The highest incidence of microcracks were associated with the ProTaper Next group, 80% ( P = 0.00), followed by the Mtwo group, 70% ( P = 0.000), and the least number of microcracks was noted in the self-adjusting file group, 10% ( P = 0.068). No significant difference was found between the ProTaper Next and Mtwo groups ( P = 0.368) while a significant difference was observed between the ProTaper Next and self-adjusting file groups ( P = 0.000) as well as the Mtwo and self-adjusting file groups ( P = 0.000). All nickel-titanium rotary instrument systems were associated with microcracks. However, the self-adjusting file system had significantly fewer microcracks when compared with the Mtwo and ProTaper Next.

  18. Influence of multiple clinical use on fatigue resistance of ProTaper rotary nickel-titanium instruments.

    PubMed

    Vieira, E P; França, E C; Martins, R C; Buono, V T L; Bahia, M G A

    2008-02-01

    To examine the influence of clinical use on the occurrence of deformation and fracture and on the fatigue resistance of ProTaper rotary instruments. Root canal treatments were performed on patients using the ProTaper rotary system. Ten sets of instruments were used by an experienced endodontist, each set in five molars. Another 10 sets of instruments were used by the same operator, each set in eight molars. In addition, 10 sets of instruments were used, each set in five molars, by undergraduate students with no clinical experience with the system. After clinical use, S1, S2, F1 and F2 instruments were analysed for damage by optical and scanning electron microscopy. The used sets, along with a control group of 12 sets of new instruments, were then tested in a bench device for fatigue resistance. The use of the ProTaper rotary instruments by an experienced endodontist allowed for the cleaning and shaping of the root canal system of up to eight molars without fracture. During the students work, six instruments fractured. Fatigue resistance decreased upon clinical use for all instruments analysed. Fatigue resistance of used instruments was reduced, but no significant change was observed amongst the instruments used for shaping the canals of five and eight molars. Operator experience affected the occurrence of fracture and plastic deformation during shaping.

  19. Tapered stems one-third proximally coated have higher complication rates than cylindrical two-third coated stems in patients with high hip dislocation undergoing total hip arthroplasty with step-cut shortening osteotomy.

    PubMed

    Ozden, V Emre; Dikmen, G; Beksac, B; Tozun, I Remzi

    2017-06-01

    The results of cementless stems in total hip arthroplasty (THA) done because of congenital dislocation with step-cut osteotomy is not well known, particularly the influence of the design and the role of extent of porous coating. Therefore we performed a retrospective study to evaluate the mid to long-term results THA performed with a single type acetabular component and different geometry and fixation type stems with ceramic bearings in the setting of step-cut subtrochanteric osteotomy in high hip dislocated (HHD) patients. We asked if the stem type affect the outcomes in terms of (1) intra and postoperative complication rates (2) radiographic outcomes (3) prosthesis survival in step-cut subtrochanteric shortening osteotomy. The type of the stem, whether cylindrical or tapered does not affect the outcome if the femoral canal fit and fill is obtained and the step-cut femoral shortening osteotomy is primarily fixed. Forty-five hips in 35 patients with a mean follow up of 10 years (range, 7-14 years) were evaluated. The single type cementless cup was placed at the level of the true acetabulum, a step-cut shortening femoral osteotomy was performed and reconstruction was performed with two different types of tapered stem in twenty-two hips (Synergy™ and Image™ proximally coated, Smith and Nephew, Menphis, TN, USA) and one type of cylindrical stem (Echelon™ with 2/3 coated, Smith and Nephew, Menphis, TN, USA) in twenty-three hips. Harris hip scores (HHS) and a University of California Los Angeles (UCLA) activity scores were calculated for all patients and successive X-rays were evaluated regarding component loosening and osteolysis, along with complications related to bearing, step-cut osteotomy and stem types. Forty-one hips (91%) had good and excellent clinical outcome according to HHS. The mean UCLA activity scores improved from 3.2±0.6 points (range, 2-4) preoperatively to 6.3 points±0.5 (range, 5-7) at the latest follow-up. The mean femoral shortening was 36

  20. Torque during canal instrumentation using rotary nickel-titanium files.

    PubMed

    Sattapan, B; Palamara, J E; Messer, H H

    2000-03-01

    Nickel-titanium engine-driven rotary instruments are used increasingly in endodontic practice. One frequently mentioned problem is fracture of an instrument in the root canal. Very few studies have been conducted on torsional characteristics of these instruments, and none has been done under dynamic conditions. The purposes of this study were to measure the torque generated and the apical force applied during instrumentation with a commercial engine-driven nickel-titanium file system, and to relate torque generated during simulated clinical use to torsional failure of the instruments. Ten extracted human teeth (five with small-sized and five with medium-sized straight root canals) were instrumented with Quantec Series 2000 files, and the torque and apical force generated were measured. The applied apical force was generally low, not exceeding 150 g in either small or medium canals. The torque depended on the tip size and taper of each instrument, and on canal size. Instruments with 0.05 and 0.06 taper generated the highest torque, which was greater in small than in medium canals. The torque at failure was significantly (p < 0.001) higher than torque during instrumentation, but with considerable variation in the extent of the difference.

  1. [Comparison of effectiveness and safety between Twisted File technique and ProTaper Universal rotary full sequence based on micro-computed tomography].

    PubMed

    Chen, Xiao-bo; Chen, Chen; Liang, Yu-hong

    2016-02-18

    To evaluate the efficacy and security of two type of rotary nickel titanium system (Twisted File and ProTaper Universal) for root canal preparation based on micro-computed tomography(micro-CT). Twenty extracted molars (including 62 canals) were divided into two experimental groups and were respectively instrumented using Twisted File rotary nickel titanium system (TF) and ProTaper Universal rotary nickel titanium system (PU) to #25/0.08 following recommended protocol. Time for root canal instrumentation (accumulation of time for every single file) was recorded. The 0-3 mm root surface from apex was observed under an optical stereomicroscope at 25 × magnification. The presence of crack line was noted. The root canals were scanned with micro-CT before and after root canal preparation. Three-dimensional shape images of canals were reconstructed, calculated and evaluated. The amount of canal central transportation of the two groups was calculated and compared. The shorter preparation time [(0.53 ± 0.14) min] was observed in TF group, while the preparation time of PU group was (2.06 ± 0.39) min (P<0.05). In mid-root level, TF group shaping resulted in less canal center transportation than PU group [(0.070 ± 0.056) mm vs. (0.097 ± 0.084) mm, P<0.05]. No instrument separation was observed in both the groups. Cracks were not found in both the groups either based in micro-CT images or observation under an optical stereomicroscope at 25 × magnification. Compared with ProTaper Universal, Twisted File took less time in root canal preparation and exhibited better shaping ability, and less canal transportation.

  2. The effect of frictional torque and bending moment on corrosion at the taper interface : an in vitro study.

    PubMed

    Panagiotidou, A; Meswania, J; Osman, K; Bolland, B; Latham, J; Skinner, J; Haddad, F S; Hart, A; Blunn, G

    2015-04-01

    The aim of this study was to assess the effect of frictional torque and bending moment on fretting corrosion at the taper interface of a modular femoral component and to investigate whether different combinations of material also had an effect. The combinations we examined were 1) cobalt-chromium (CoCr) heads on CoCr stems 2) CoCr heads on titanium alloy (Ti) stems and 3) ceramic heads on CoCr stems. In test 1 increasing torque was imposed by offsetting the stem in the anteroposterior plane in increments of 0 mm, 4 mm, 6 mm and 8 mm when the torque generated was equivalent to 0 Nm, 9 Nm, 14 Nm and 18 Nm. In test 2 we investigated the effect of increasing the bending moment by offsetting the application of axial load from the midline in the mediolateral plane. Increments of offset equivalent to head + 0 mm, head + 7 mm and head + 14 mm were used. Significantly higher currents and amplitudes were seen with increasing torque for all combinations of material. However, Ti stems showed the highest corrosion currents. Increased bending moments associated with using larger offset heads produced more corrosion: Ti stems generally performed worse than CoCr stems. Using ceramic heads did not prevent corrosion, but reduced it significantly in all loading configurations. ©2015 The British Editorial Society of Bone & Joint Surgery.

  3. Titanium-titanium modular neck for primary THA. Result of a prospective series of 170 cemented THA with a minimum follow-up of 5 years.

    PubMed

    Ollivier, M; Parratte, S; Galland, A; Lunebourg, A; Flecher, X; Argenson, J-N

    2015-04-01

    Although they have been in use since the end of the 1980s, modular titanium neck components are associated with a risk of wear or fracture, and their safety has recently become a subject of debate and has never been evaluated in a consecutive series of patients. The goal of this study was to evaluate: revision-free survival of these implants after a minimum follow-up of 5 years; clinical and radiographic results; and the potential complications associated with the use of modular titanium neck components. The use of titanium modular neck on cemented titanium THA is safe at a minimum follow-up of 5 years. Between January 2006 and December 2008, we prospectively followed 170 patients (170 hips) who underwent primary anatomical THA with a modular cemented titanium stem design implant. The indications were unilateral THA for primary (n=160) or secondary (n=10) hip osteoarthritis (aseptic osteonecrosis of the femoral head or hip dysplasia). Mean age of patients was 75.4±5.8 years old (52-85), and mean BMI was 26.1±4.5 kg/m(2) (16.6-42.1). Patients were operated on by a modified Watson-Jones anterolateral approach based on preoperative 2D planning. All patients underwent annual clinical and radiological follow-up by an independent observer. At a mean follow-up of 71±8 months (60-84), 5 patients died and 7 were lost to follow-up. There was no revision of THA after a maximum follow-up of 84 months. The Harris score improved significantly from 50.4±11.3 (0-76) preoperatively to 84.5±15.2 (14-100) at the final follow-up. There was no difference in postoperative femoral offset or the position of the center of rotation compared to the opposite side. On the other hand, the neck-shaft angle (NSA) and limb length were corrected (2±5° [-11 to +14°] and 2.16±3.6 mm [-7.4 to +12.7 mm]) respectively. Fifteen patients (9%) had limb length discrepancies of more than 5 mm and 4 patients (2%) of more than 10 mm. There were no complications due to the modular implant design. Our

  4. Tapering Practices of Strongman Athletes.

    PubMed

    Winwood, Paul W; Dudson, Mike K; Wilson, Daniel; Mclaren-Harrison, Justice K H; Redjkins, Vladislav; Pritchard, Hayden J; Keogh, Justin W L

    2018-05-01

    Winwood, PW, Dudson, MK, Wilson, D, Mclaren-Harrison, JKH, Redjkins, V, Pritchard, HJ, and Keogh, JWL. Tapering practices of strongman athletes. J Strength Cond Res 32(5): 1181-1196, 2018-This study provides the first empirical evidence of how strongman athletes taper for strongman competitions. Strongman athletes (n = 454) (mean ± SD: 33.2 ± 8.0 years, 178.1 ± 10.6 cm, 108.6 ± 27.9 kg, 12.6 ± 8.9 years general resistance training, 5.3 ± 5.0 years strongman implement training) completed a self-reported 4-page internet survey on tapering practices. Analysis by sex (male and female), age (≤30 and >30 years), body mass (≤105 and >105 kg), and competitive standard (local/regional amateur, national amateur and professional) was conducted. Eighty-seven percent (n = 396) of strongman athletes reported that they used a taper. Athletes stated that their typical taper length was 8.6 ± 5.0 days, with the step taper the most commonly performed taper (52%). Training volume decreased during the taper by 45.5 ± 12.9%, and all training ceased 3.9 ± 1.8 days out from competition. Typically, athletes reported that training frequency and training duration stayed the same or decreased and training intensity decreased to around 50% in the last week. Athletes generally stated that tapering was performed to achieve recovery, rest, and peak performance; the deadlift, yoke walk, and stone lifts/work took longer to recover from than other lifts; assistance exercises were reduced or removed in the taper; massage, foam rolling, nutritional changes, and static stretching were strategies used in the taper; and, poor tapering occurred when athletes trained too heavy/hard or had too short a taper. These data will assist strongman athletes and coaches in the optimization of tapering variables leading to more peak performances. Future research could investigate the priming and preactivation strategies strongman athletes use on competition day.

  5. Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions?

    PubMed

    Pourzal, Robin; Hall, Deborah J; Ha, Nguyen Q; Urban, Robert M; Levine, Brett R; Jacobs, Joshua J; Lundberg, Hannah J

    2016-10-01

    There are increasing reports of total hip arthroplasty failure subsequent to modular taper junction corrosion. The surfaces of tapers are machined to have circumferential machining marks, resulting in a surface topography of alternating peaks and valleys on the scale of micrometers. It is unclear if the geometry of this machined surface topography influences the degree of fretting and corrosion damage present on modular taper junctions or if there are differences between modular taper junction material couples. (1) What are the differences in damage score and surface topography between CoCr/CoCr and CoCr/Ti modular junctions? (2) How are initial surface topography, flexural rigidity, taper angle mismatch, and time in situ related to visual taper damage scores for CoCr/CoCr couples? (3) How are initial surface topography, flexural rigidity, taper angle mismatch, and time in situ related to visual taper damage scores for CoCr/Ti couples? Damage on stem and head tapers was evaluated with a modified Goldberg score. Differences in damage scores were determined between a group of 140 CoCr/CoCr couples and 129 CoCr/Ti couples using a chi-square test. For a subgroup of 70 retrievals, selected at random, we measured five variables, including initial stem taper machining mark height and spacing, initial head taper roughness, flexural rigidity, and taper angle mismatch. All retrievals were obtained at revision surgeries. None were retrieved as a result of metal-on-metal failures or were recalled implants. Components were chosen so there was a comparable number of each material couple and damage score. Machining marks around the circumference of the tapers were measured using white light interferometry to characterize the initial stem taper surface topography in terms of the height of and spacing between machining mark peaks as well as initial head taper roughness. The taper angle mismatch was assessed with a coordinate measuring machine. Flexural rigidity was determined based

  6. Corrosion at the head-neck interface of current designs of modular femoral components: essential questions and answers relating to corrosion in modular head-neck junctions.

    PubMed

    Osman, K; Panagiotidou, A P; Khan, M; Blunn, G; Haddad, F S

    2016-05-01

    There is increasing global awareness of adverse reactions to metal debris and elevated serum metal ion concentrations following the use of second generation metal-on-metal total hip arthroplasties. The high incidence of these complications can be largely attributed to corrosion at the head-neck interface. Severe corrosion of the taper is identified most commonly in association with larger diameter femoral heads. However, there is emerging evidence of varying levels of corrosion observed in retrieved components with smaller diameter femoral heads. This same mechanism of galvanic and mechanically-assisted crevice corrosion has been observed in metal-on-polyethylene and ceramic components, suggesting an inherent biomechanical problem with current designs of the head-neck interface. We provide a review of the fundamental questions and answers clinicians and researchers must understand regarding corrosion of the taper, and its relevance to current orthopaedic practice. Cite this article: Bone Joint J 2016;98-B:579-84. ©2016 The British Editorial Society of Bone & Joint Surgery.

  7. Bearing-Foreign Material Deposition on Retrieved Co-Cr Femoral Heads: Composition and Morphology

    PubMed Central

    Tikekar, Nishant M.; Heiner, Anneliese D.; Baer, Thomas E.; Kruger, Karen M.; Callaghan, John J.; Brown, Thomas D.; Lannutti, John J.

    2015-01-01

    Bearing-foreign material deposition onto a femoral head can occur from contact with an acetabular shell due to dislocation, reduction, or subluxation. The purpose of this study was to comprehensively characterize deposit regions on retrieved cobalt-chrome femoral heads from metal-on-polyethylene total hip arthroplasties that had experienced such adverse events. The morphology, topography, and composition of deposition regions were characterized using macrophotography, optical profilometry, scanning electron microscopy, energy dispersive spectroscopy, and X-ray photoelectron spectroscopy. The deposit areas were relatively large, they were much rougher than the surrounding undamaged clean areas, and they displayed several distinct morphologies. Titanium alloy elements were the predominant constituents. Calcium and phosphorous were also detected within the deposit areas, in a composition that could nucleate abrasive hydroxyapatite. In addition, tungsten-rich particles, likely present as tungsten carbide, were observed on top of the titanium deposits. The increased roughness associated with these deposition features would be expected to accelerate damage and wear of the opposing liner and hence accelerate the development of osteolysis. PMID:26236744

  8. Cyclic fatigue resistance of two nickel-titanium rotary instruments in interrupted rotation.

    PubMed

    Pedullà, E; Lizio, A; Scibilia, M; Grande, N M; Plotino, G; Boninelli, S; Rapisarda, E; Lo Giudice, G

    2017-02-01

    To investigate the influence of interrupted rotation on cyclic fatigue of two nickel-titanium rotary instruments. Cyclic fatigue of 300 new ProTaper Next size X1; X2 and Mtwo size 10, .04 taper; size 15, .05 taper; size 20, .06 taper and size 25, .06 taper instruments was tested in continuous or interrupted rotation. Fifty files of the same brand and size were randomly assigned to five groups (n = 10). Group 1 instruments were tested in continuous rotation; groups 2 and 3 in paused rotation for 1 s every 10 or 20 s, respectively; groups 4 and 5 in interrupted rotation for 5 s every 10 or 20 s, respectively. Cyclic fatigue was expressed in time to fracture (TtF) in an artificial canal with 60° angle and 5 mm radius of curvature. The fracture surface was examined with a scanning electron microscope (SEM). Data were evaluated by two-way analysis of variance. Cyclic fatigue of groups 2 and 4 of ProTaper Next X2 and Mtwo size 25, .06 taper was significantly lower than that of group 1 of the same instruments (P < 0.01). ProTaper Next X2 had significantly reduced cyclic fatigue in groups 3 and 5 (P < 0.05). No differences were found by interrupting the rotation for 1 or 5 s in all instruments (P > 0.05). Fatigue of other instruments was not affected by interrupted rotation (P > 0.05). Interrupted rotation reduced cyclic fatigue resistance of ProTaper Next X2 and Mtwo size 25, .06 taper, especially when a higher number of interruptions was performed. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  9. High risk of early periprosthetic fractures after primary hip arthroplasty in elderly patients using a cemented, tapered, polished stem.

    PubMed

    Brodén, Cyrus; Mukka, Sebastian; Muren, Olle; Eisler, Thomas; Boden, Henrik; Stark, André; Sköldenberg, Olof

    2015-04-01

    Postoperative periprosthetic femoral fracture (PPF) after hip arthroplasty is associated with considerable morbidity and mortality. We assessed the incidence and characteristics of periprosthetic fractures in a consecutive cohort of elderly patients treated with a cemented, collarless, polished and tapered femoral stem (CPT). In this single-center prospective cohort study, we included 1,403 hips in 1,357 patients (mean age 82 (range 52-102) years, 72% women) with primary osteoarthritis (OA) or a femoral neck fracture (FNF) as indication for surgery (367 hips and 1,036 hips, respectively). 64% of patients were ASA class 3 or 4. Hip-related complications and need for repeat surgery were assessed at a mean follow-up time of 4 (1-7) years. A Cox regression analysis was used to evaluate risk factors associated with PPF. 47 hips (3.3%) sustained a periprosthetic fracture at median 7 (2-79) months postoperatively; 41 were comminute Vancouver B2 or complex C-type fractures. The fracture rate was 3.8% for FNF patients and 2.2% for OA patients (hazard ratio (HR) = 4; 95% CI: 1.3-12). Patients > 80 years of age also had a higher risk of fracture (HR = 2; 95% CI: 1.1-4.5). We found a high incidence of early PPF associated with the CPT stem in this old and frail patient group. A possible explanation may be that the polished tapered stem acts as a wedge, splitting the femur after a direct hip contusion. Our results should be confirmed in larger, registry-based studies, but we advise caution when using this stem for this particular patient group.

  10. Stress on external hexagon and Morse taper implants submitted to immediate loading

    PubMed Central

    Odo, Caroline H.; Pimentel, Marcele J.; Consani, Rafael L.X.; Mesquita, Marcelo F.; Nóbilo, Mauro A.A.

    2015-01-01

    Background/Aims This study aimed to evaluate the stress distribution around external hexagon (EH) and Morse taper (MT) implants with different prosthetic systems of immediate loading (distal bar (DB), casting technique (CT), and laser welding (LW)) by using photoelastic method. Methods Three infrastructures were manufactured on a model simulating an edentulous lower jaw. All models were composed by five implants (4.1 mm × 13.0 mm) simulating a conventional lower protocol. The samples were divided into six groups. G1: EH implants with DB and acrylic resin; G2: EH implants with titanium infrastructure CT; G3: EH implants with titanium infrastructure attached using LW; G4: MT implants with DB and acrylic resin; G5: MT implants with titanium infrastructure CT; G6: MT implants with titanium infrastructure attached using LW. After the infrastructures construction, the photoelastic models were manufactured and a loading of 4.9 N was applied in the cantilever. Five pre-determined points were analyzed by Fringes software. Results Data showed significant differences between the connection types (p < 0.0001), and there was no significant difference among the techniques used for infrastructure. Conclusion The reduction of the stress levels was more influenced by MT connection (except for CT). Different bar types submitted to immediate loading not influenced stress concentration. PMID:26605142

  11. The histological and elemental characterisation of corrosion particles from taper junctions.

    PubMed

    Munir, S; Oliver, R A; Zicat, B; Walter, W L; Walter, W K; Walsh, W R

    2016-09-01

    This study aimed to characterise and qualitatively grade the severity of the corrosion particles released into the hip joint following taper corrosion. The 26 cases examined were CoC/ABG Modular (n = 13) and ASR/SROM (n = 13). Blood serum metal ion levels were collected before and after revision surgery. The haematoxylin and eosin tissue sections were graded on the presence of fibrin exudates, necrosis, inflammatory cells and corrosion products. The corrosion products were identified based on visible observation and graded on abundance. Two independent observers blinded to the clinical patient findings scored all cases. Elemental analysis was performed on corrosion products within tissue sections. X-Ray diffraction was used to identify crystalline structures present in taper debris. The CoC/ABG Modular patients had a mean age of 64.6 years (49.4 to 76.5) and ASR/SROM patients had a mean age of 58.2 years (33.3 to 85.6). The mean time in situ for CoC/ABG was 4.9 years (2 to 6.4) and ASR/SROM was 6.1 years (2.5 to 8.1). The blood serum metal ion concentrations reduced following revision surgery with the exception of Cr levels within CoC/ABG. The grading of tissue sections showed that the macrophage response and metal debris were significantly higher for the ASR/SROM patients (p < 0.001). The brown/red particles were significantly higher for ASR/SROM (p < 0.001). The taper debris contained traces of titanium oxide, chromium oxide and aluminium nitride. This study characterised and qualitatively graded the severity of the corrosion particles released into the hip joint from tapers that had corrosion damage.Cite this article: S. Munir, R. A. Oliver, B. Zicat, W. L. Walter, W. K. Walter, W. R. Walsh. The histological and elemental characterisation of corrosion particles from taper junctions. Bone Joint Res 2016;5:370-378. DOI: 10.1302/2046-3758.59.2000507. © 2016 Munir et al.

  12. Comparison of apical transportation between ProFile and ProTaper NiTi rotary instruments.

    PubMed

    Iqbal, M K; Firic, S; Tulcan, J; Karabucak, B; Kim, S

    2004-06-01

    To use a newly developed radiographic technique to compare apical transportation and loss of working length (WL) between.06 taper ProFile Series 29 and ProTaper nickel-titanium (NiTi) rotary instruments in vitro. Mesio-buccal canals of 40 extracted mandibular molars were randomly divided into two groups. Group 1 was instrumented with ProFile and group 2 with ProTaper instruments according to the manufacturers' directions. A specially constructed radiographic jig with a Schick digital radiographic system (Schick Technologies Inc., Long Island City, NY, USA) was used to take pre- and postoperative radiographs of the samples at predetermined angulations. Using AutoCAD 2000 (Autodesk Inc., San Rafael, CA, USA), the central axes of initial and final instruments were radiographically superimposed to determine the loss of WL and degree of transportation at D(0), D(1), D(2) and D(4) from the WL. Data were analysed using repeated-measures anova. A statistically significant difference in apical transportation was found at the D(4) level between the two groups (P = 0.05). There was no statistical significance regarding postinstrumentation change in WL between groups. Spearman's Bivariate Correlation analysis indicated no statistically significant relationship between the radius of curvature and transportation. The results indicate that both ProTaper and ProFile instruments are comparable to each other in regards to their ability to optimally enlarge root canal with minimal transportation and loss of WL in vitro.

  13. Fully porous 3D printed titanium femoral stem to reduce stress-shielding following total hip arthroplasty.

    PubMed

    Arabnejad, Sajad; Johnston, Burnett; Tanzer, Michael; Pasini, Damiano

    2017-08-01

    Current hip replacement femoral implants are made of fully solid materials which all have stiffness considerably higher than that of bone. This mechanical mismatch can cause significant bone resorption secondary to stress shielding, which can lead to serious complications such as peri-prosthetic fracture during or after revision surgery. In this work, a high strength fully porous material with tunable mechanical properties is introduced for use in hip replacement design. The implant macro geometry is based off of a short stem taper-wedge implant compatible with minimally invasive hip replacement surgery. The implant micro-architecture is fine-tuned to locally mimic bone tissue properties which results in minimum bone resorption secondary to stress shielding. We present a systematic approach for the design of a 3D printed fully porous hip implant that encompasses the whole activity spectrum of implant development, from concept generation, multiscale mechanics of porous materials, material architecture tailoring, to additive manufacturing, and performance assessment via in vitro experiments in composite femurs. We show that the fully porous implant with an optimized material micro-structure can reduce the amount of bone loss secondary to stress shielding by 75% compared to a fully solid implant. This result also agrees with those of the in vitro quasi-physiological experimental model and the corresponding finite element model for both the optimized fully porous and fully solid implant. These studies demonstrate the merit and the potential of tuning material architecture to achieve a substantial reduction of bone resorption secondary to stress shielding. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1774-1783, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  14. Comparison of cyclic fatigue resistance of novel nickel-titanium rotary instruments.

    PubMed

    Capar, Ismail Davut; Ertas, Huseyin; Arslan, Hakan

    2015-04-01

    New files (ProTaper Next/HyFlex/OneShape) are made from novel nickel-titanium (NiTi) alloys/treatments. The purpose of this study was to compare the cyclic fatigue resistance of these new instruments with that of Revo-S instruments. Four groups of 20 NiTi endodontic instruments were tested in steel canals with a 3 mm radius and a 60° angle of curvature. The cyclic fatigue of the following NiTi instruments with a tip size 25 and 0.06 taper that were manufactured with different alloys was tested: ProTaper Next X2 (M-Wire), OneShape (conventional NiTi), Revo-S Shaping Universal (conventional NiTi) and HyFlex 25/0.6 (controlled memory NiTi wire). A one-way anova and post-hoc Tukey's test (α = 0.05) revealed that the HyFlex files had the highest fatigue resistance and the Revo-S had the least fatigue resistance among the groups (P < 0.001). © 2014 Australian Society of Endodontology.

  15. Enhancing sensitivity of biconical tapered fiber sensors with multiple passes through the taper

    NASA Astrophysics Data System (ADS)

    Cohoon, Gregory; Boyter, Chris; Errico, Michael; Vandervoort, Kurt; Salik, Ertan

    2010-03-01

    A single biconical fiber taper is a simple and low-cost yet powerful sensor. With a distinct strength in refractive index (RI) sensing, biconical tapered fiber sensors can find their place in handheld sensor platforms, especially as biosensors that are greatly needed in health care, environmental protection, food safety, and biodefense. We report doubling of sensitivity for these sensors with two passes through the tapered region, which becomes possible through the use of sensitive and high-dynamic-range photodetectors. In a proof-of-principle experiment, we measured transmission through the taper when it was immersed in isopropyl alcohol-water mixtures of varying concentrations, in which a thin gold layer at the tip of the fiber acted as a mirror enabling two passes through the tapered region. This improved the sensitivity from 0.43 dB/vol % in the single-pass case to 0.78 dB/vol % with two passes through the taper. The refractive index detection limit was estimated to be ~1.2×10-5 RI units (RIU) and ~0.6×10-5 RIU in the single- and double-pass schemes, respectively. We predict that further enhancement of sensitivity may be achieved with a higher number of passes through the taper.

  16. Undisplaced Intraoperative Fracture Presenting as Early Dislocation with Tapered Wedge Stems in Total Hip Arthroplasty - Case Series and Review of Literature

    PubMed Central

    Reddy, A V Gurava; Eachempati, Krishna Kiran; Mugalur, Aakash; Suchinder, A; Rao, V B N Prasad; Kamurukuru, Nalanda

    2017-01-01

    Introduction: Periprosthetic fractures and dislocation in the early post-operative period can be disastrous both for the surgeon and the patient. However, undisplaced periprosthetic fractures presenting with dislocation is uncommon. We describe successful management of two cases (one bilateral dislocation and one unilateral dislocation) of undisplaced iatrogenic fractures in total hip arthroplasty (THA) presenting as early dislocation. Case Report: Case 1 was a 45-year-old female with osteoarthritis of hip secondary to developmental dysplasia of the hip with bilateral early nontraumatic dislocation with bilateral identical periprosthetic fracture. It was managed by revision to long stem and encirclage wiring. Case 2 presented with early dislocation in the 2nd week post THA. We found an intertrochanteric fracture intra-operatively with unstable implant. Acetabular component and femoral component revision were done with reconstruction of the greater trochanter. Discussion: These fractures could be occult iatrogenic fractures characteristic of taper wedge stems which presented as early nontraumatic dislocation in the post-operative period. The prosthesis subsidence, loss of muscle tension and change of version might be the factors leading to dislocation. Conclusion: Unrecognized incomplete intraoperative fracture can occur with tapered wedge uncemented stems which can present as a dislocation in the immediate post-operative period. This will require early revision of the femoral component. PMID:29051875

  17. Energy partitioning and impulse dispersion in the decorated, tapered, strongly nonlinear granular alignment: A system with many potential applications

    NASA Astrophysics Data System (ADS)

    Doney, Robert L.; Agui, Juan H.; Sen, Surajit

    2009-09-01

    Rapid absorption of impulses using light-weight, small, reusable systems is a challenging problem. An axially aligned set of progressively shrinking elastic spheres, a "tapered chain," has been shown to be a versatile and scalable shock absorber in earlier simulational, theoretical, and experimental works by several authors. We have recently shown (see R. L. Doney and S. Sen, Phys. Rev. Lett. 97, 155502 (2006)) that the shock absorption ability of a tapered chain can be dramatically enhanced by placing small interstitial grains between the regular grains in the tapered chain systems. Here we focus on a detailed study of the problem introduced in the above mentioned letter, present extensive dynamical simulations using parameters for a titanium-aluminum-vanadium alloy Ti6Al4V, derive attendant hard-sphere analyses based formulae to describe energy dispersion, and finally discuss some preliminary experimental results using systems with chrome spheres and small Nitinol interstitial grains to present the underlying nonlinear dynamics of this so-called decorated tapered granular alignment. We are specifically interested in small systems, comprised of several grains. This is because in real applications, mass and volume occupied must inevitably be minimized. Our conclusion is that the decorated tapered chain offers enhanced energy dispersion by locking in much of the input energy in the grains of the tapered chain rather than in the small interstitial grains. Thus, the present study offers insights into how the shock absorption capabilities of these systems can be pushed even further by improving energy absorption capabilities of the larger grains in the tapered chains. We envision that these scalable, decorated tapered chains may be used as shock absorbing components in body armor, armored vehicles, building applications and in perhaps even in applications in rehabilitation science.

  18. Application of fiber tapers in astronomy

    NASA Astrophysics Data System (ADS)

    Marcel, Jaclyn; Haynes, Roger; Bland-Hawthorn, Joss

    2006-06-01

    Fiber tapers have the potential to significantly advance instrument technology into the realm of fully integrated optical systems. Our initial investigation was directed at the use of fiber tapers as f-ratio transformation devices. Using a technique developed for testing focal ratio degradation (FRD), a collimated light source was injected at different angles into various fiber taper samples and the far-field profile of the fiber output was observed. We compare the FRD present in the optical fiber tapers with conventional fibers and determine how effectively fiber tapers perform as image converters. We demonstrate that while silica fiber tapers may have slightly more intrinsic FRD than conventional fibers they still show promise as adiabatic mode transformers and are worth investigating further for their potential use in astronomical instruments. In this paper we present a brief review of the current status of fiber tapers with particular focus on the astronomical applications. We demonstrate the conservation of etendue in the taper transformation process and present the experimental results for a number of different taper profiles and manufacturers.

  19. Efficacy of ProTaper universal retreatment files in removing filling materials during root canal retreatment.

    PubMed

    Giuliani, Valentina; Cocchetti, Roberto; Pagavino, Gabriella

    2008-11-01

    The aim of this study was to evaluate the efficacy of the ProTaper Universal System rotary retreatment system and of Profile 0.06 and hand instruments (K-file) in the removal of root filling materials. Forty-two extracted single-rooted anterior teeth were selected. The root canals were enlarged with nickel-titanium (NiTi) rotary files, filled with gutta-percha and sealer, and randomly divided into 3 experimental groups. The filling materials were removed with solvent in conjunction with one of the following devices and techniques: the ProTaper Universal System for retreatment, ProFile 0.06, and hand instruments (K-file). The roots were longitudinally sectioned, and the image of the root surface was photographed. The images were captured in JPEG format; the areas of the remaining filling materials and the time required for removing the gutta-percha and sealer were calculated by using the nonparametric one-way Kruskal-Wallis test and Tukey-Kramer tests, respectively. The group that showed better results for removing filling materials was the ProTaper Universal System for retreatment files, whereas the group of ProFile rotary instruments yielded better root canal cleanliness than the hand instruments, even though there was no statistically significant difference. The ProTaper Universal System for retreatment and ProFile rotary instruments worked significantly faster than the K-file. The ProTaper Universal System for retreatment files left cleaner root canal walls than the K-file hand instruments and the ProFile Rotary instruments, although none of the devices used guaranteed complete removal of the filling materials. The rotary NiTi system proved to be faster than hand instruments in removing root filling materials.

  20. Tapered structure construction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Eric D.; Takata, Rosalind K.; Slocum, Alexander H.

    Feeding stock used to form a tapered structure into a curving device such that each point on the stock undergoes rotational motion about a peak location of the tapered structure; and the stock meets a predecessor portion of stock along one or more adjacent edges.

  1. Clinical significance of corrosion of cemented femoral stems in metal-on-metal hips: a retrieval study.

    PubMed

    Hothi, Harry S; Berber, Reshid; Panagiotopoulos, Andreas C; Whittaker, Robert K; Rhead, Camilla; Skinner, John A; Hart, Alister J

    2016-11-01

    The clinical significance of corrosion of cemented femoral stems is unclear. The purpose of this retrieval study was to: (1) report on corrosion at the stem-cement interface and (2) correlate these findings with clinical data. We analysed cemented stems (n = 36) composed of cobalt-chromium (CoCr) and stainless steel (SS) in a series of revised metal-on-metal hips. We performed detailed inspection of each stem to assess the severity of corrosion at the stem-cement interface using a scale of 1 (low) to 5 (severe). We assessed the severity of corrosion at each stem trunnion and measured wear rates at the head taper and bearing surfaces. We used non-parametric tests to determine the significance of differences between the CoCr and SS stems in relation to: (1) pre-revision whole blood Co and Cr metal ion levels, (2) trunnion corrosion, (3) bearing surface wear and (4) taper material loss. The corrosion scores of CoCr stems were significantly greater than SS stems (p < 0.01). Virtually all stem trunnions in both alloy groups had minimal evidence of corrosion. The median pre-revision Co levels of implants with CoCr stems were significantly greater than the SS stems (p < 0.01). There was no significant difference in relation to pre-revision Cr levels (p = 0.521). There was no significant difference between the two stem types in relation to bearing wear (p = 0.926) or taper wear (p = 0.148). Severe corrosion of cemented femoral stems is a common finding at our retrieval centre; surgeons should consider corrosion of CoCr stems as a potential source of metal ions when revising a hip.

  2. High risk of early periprosthetic fractures after primary hip arthroplasty in elderly patients using a cemented, tapered, polished stem

    PubMed Central

    Brodén, Cyrus; Mukka, Sebastian; Muren, Olle; Eisler, Thomas; Boden, Henrik; Stark, André; Sköldenberg, Olof

    2015-01-01

    Background and purpose Postoperative periprosthetic femoral fracture (PPF) after hip arthroplasty is associated with considerable morbidity and mortality. We assessed the incidence and characteristics of periprosthetic fractures in a consecutive cohort of elderly patients treated with a cemented, collarless, polished and tapered femoral stem (CPT). Patients and methods In this single-center prospective cohort study, we included 1,403 hips in 1,357 patients (mean age 82 (range 52–102) years, 72% women) with primary osteoarthritis (OA) or a femoral neck fracture (FNF) as indication for surgery (367 hips and 1,036 hips, respectively). 64% of patients were ASA class 3 or 4. Hip-related complications and need for repeat surgery were assessed at a mean follow-up time of 4 (1–7) years. A Cox regression analysis was used to evaluate risk factors associated with PPF. Results 47 hips (3.3%) sustained a periprosthetic fracture at median 7 (2–79) months postoperatively; 41 were comminute Vancouver B2 or complex C-type fractures. The fracture rate was 3.8% for FNF patients and 2.2% for OA patients (hazard ratio (HR) = 4; 95% CI: 1.3–12). Patients > 80 years of age also had a higher risk of fracture (HR = 2; 95% CI: 1.1–4.5). Interpretation We found a high incidence of early PPF associated with the CPT stem in this old and frail patient group. A possible explanation may be that the polished tapered stem acts as a wedge, splitting the femur after a direct hip contusion. Our results should be confirmed in larger, registry-based studies, but we advise caution when using this stem for this particular patient group. PMID:25280133

  3. Tapered fiber nanoprobes: plasmonic nanopillars on tapered optical fiber tips for large EM enhancement.

    PubMed

    Savaliya, Priten; Dhawan, Anuj

    2016-10-01

    Employing finite difference time domain simulations, we demonstrate that electromagnetic field enhancement is substantially greater for tapered optical fibers with plasmonic nanostructures present on their tips as compared with non-tapered optical fibers having those plasmonic nanostructures, or with tapered optical fibers without the plasmonic nanostructures. We also carried out fabrication of plasmonic nanostructures on optical fiber tips.

  4. Analysis of Femoral Components of Cemented Total Hip Arthroplasty

    NASA Astrophysics Data System (ADS)

    Singh, Shantanu; Harsha, A. P.

    2016-10-01

    There have been continuous on-going revisions in design of prosthesis in Total Hip Arthroplasty (THA) to improve the endurance of hip replacement. In the present work, Finite Element Analysis was performed on cemented THA with CoCrMo trapezoidal, CoCrMo circular, Ti6Al4V trapezoidal and Ti6Al4V circular stem. It was observed that cross section and material of femoral stem proved to be critical parameters for stress distribution in femoral components, distribution of interfacial stress and micro movements. In the first part of analysis, designs were investigated for micro movements and stress developed, for different stem materials. Later part of the analysis focused on investigations with respect to different stem cross sections. Femoral stem made of Titanium alloy (Ti6Al4V) resulted in larger debonding of stem at cement-stem interface and increased stress within the cement mantle in contrast to chromium alloy (CoCrMo) stem. Thus, CoCrMo proved to be a better choice for cemented THA. Comparison between CoCrMo femoral stem of trapezium and circular cross section showed that trapezoidal stem experiences lesser sliding and debonding at interfaces than circular cross section stem. Also, trapezium cross section generated lower peak stress in femoral stem and cortical femur. In present study, femur head with diameter of 36 mm was considered for the analysis in order to avoid dislocation of the stem. Also, metallic femur head was coupled with cross linked polyethylene liner as it experiences negligible wear compared to conventional polyethylene liner and unlike metallic liner it is non carcinogenic.

  5. Geosynchronous Performance of a Lithium-titanium Disulfide Battery

    NASA Technical Reports Server (NTRS)

    Otzinger, B.

    1985-01-01

    An ambient temperature rechargeable Lithium-Titanium disulfide (Li-TiS2) five cell battery has completed the first orbital year of accelerated synchronous orbit testing. A novel charge/discharge, state of charge (SOC) control scheme is utilized, together with taper current charge backup to overcome deleterious effects associated with high end of charge and low end of discharge voltages. It is indicated that 10 orbital years of simulated synchronous operation may be achieved. Preliminary findings associated with cell matching and battery performance are identified.

  6. Tapered GRIN fiber microsensor.

    PubMed

    Beltrán-Mejía, Felipe; Biazoli, Claudecir R; Cordeiro, Cristiano M B

    2014-12-15

    The sensitivity of an optical fiber microsensor based on inter-modal interference can be considerably improved by tapering a short extension of the multimode fiber. In the case of Graded Index fibers with a parabolic refractive index profile, a meridional ray exhibits a sinusoidal path. When these fibers are tapered, the period of the propagated beam decrease down-taper and increase up-taper. We take advantage of this modulation -along with the enhanced overlap between the evanescent field and the external medium- to substantially increase the sensitivity of these devices by tuning the sensor's maximum sensitivity wavelength. Moreover, the extension of this device is reduced by one order of magnitude, making it more propitious for reduced space applications. Numerical and experimental results demonstrate the success and feasibility of this approach.

  7. Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model.

    PubMed

    Yao, James H; Schwartz, Scott A; Beeson, Thomas J

    2006-01-01

    The cyclic fatigue resistance of three types of nickel-titanium rotary files was compared in a model using reciprocating axial movement. The influence of file size and taper was also investigated and fracture patterns were examined under SEM. The 10 experimental groups consisted of ProFiles, K3s, and RaCe files, size 25 in .04 and .06 tapers, as well as ProFiles and K3s, size 40 in .04 and .06 tapers. Each file was rotated freely at 300 rpm inside a stainless steel tube with a 60 degree and 5 mm radius of curvature. A continuous 3 mm oscillating axial motion was applied at 1 cycle per second by attaching an electric dental handpiece to the most inferior load cell of an Instron machine using a custom-made jig. The number of rotations to failure was determined and analyzed using analysis of variance and Tukey's post hoc tests. Overall, K3 25/.04 files were significantly more resistant to cyclic fatigue compared to any other group in this study. In the 25/.04 category, K3s were significantly more resistant to failure than ProFiles and RaCe files. Also in the same category, ProFiles significantly outlasted RaCe files. In the 25/.06 group, K3s and ProFiles were significantly more resistant to failure than RaCe files, but K3s were not significantly different than ProFiles. In the 40/.04 and 40/.06 groups, K3s were significantly more resistant to cyclic fatigue than ProFiles. SEM observations demonstrated mostly a ductile mode of fracture. The results suggest that different cross-sectional designs, diameters, and tapers all contribute to a nickel-titanium instrument's vulnerability to cyclic failure.

  8. Comparative study of six rotary nickel-titanium systems and hand instrumentation for root canal preparation.

    PubMed

    Guelzow, A; Stamm, O; Martus, P; Kielbassa, A M

    2005-10-01

    To compare ex vivo various parameters of root canal preparation using a manual technique and six different rotary nickel-titanium (Ni-Ti) instruments (FlexMaster, System GT, HERO 642, K3, ProTaper, and RaCe). A total of 147 extracted mandibular molars were divided into seven groups (n = 21) with equal mean mesio-buccal root canal curvatures (up to 70 degrees), and embedded in a muffle system. All root canals were prepared to size 30 using a crown-down preparation technique for the rotary nickel-titanium instruments and a standardized preparation (using reamers and Hedströem files) for the manual technique. Length modifications and straightening were determined by standardized radiography and a computer-aided difference measurement for every instrument system. Post-operative cross-sections were evaluated by light-microscopic investigation and photographic documentation. Procedural errors, working time and time for instrumentation were recorded. The data were analysed statistically using the Kruskal-Wallis test and the Mann-Whitney U-test. No significant differences were detected between the rotary Ni-Ti instruments for alteration of working length. All Ni-Ti systems maintained the original curvature well, with minor mean degrees of straightening ranging from 0.45 degrees (System GT) to 1.17 degrees (ProTaper). ProTaper had the lowest numbers of irregular post-operative root canal diameters; the results were comparable between the other systems. Instrument fractures occurred with ProTaper in three root canals, whilst preparation with System GT, HERO 642, K3 and the manual technique resulted in one fracture each. Ni-Ti instruments prepared canals more rapidly than the manual technique. The shortest time for instrumentation was achieved with System GT (11.7 s). Under the conditions of this ex vivo study all Ni-Ti systems maintained the canal curvature, were associated with few instrument fractures and were more rapid than a standardized manual technique. ProTaper

  9. Buprenorphine tapering schedule and illicit opioid use

    PubMed Central

    Ling, Walter; Hillhouse, Maureen; Domier, Catherine; Doraimani, Geetha; Hunter, Jeremy; Thomas, Christie; Jenkins, Jessica; Hasson, Albert; Annon, Jeffrey; Saxon, Andrew; Selzer, Jeffrey; Boverman, Joshua; Bilangi, Richard

    2011-01-01

    Aims To compare the effects of a short or long taper schedule after buprenorphine stabilization on participant outcomes as measured by opioid-free urine tests at the end of each taper period. Design This multi-site study sponsored by Clinical Trials Network (CTN, a branch of the US National Institute on Drug Abuse) was conducted from 2003 to 2005 to compare two taper conditions (7 days and 28 days). Data were collected at weekly clinic visits to the end of the taper periods, and at 1-month and 3-month post-taper follow-up visits. Setting Eleven out-patient treatment programs in 10 US cities. Intervention Non-blinded dosing with Suboxone® during the 1-month stabilization phase included 3 weeks of flexible dosing as determined appropriate by the study physicians. A fixed dose was required for the final week before beginning the taper phase. Measurements The percentage of participants in each taper group providing urine samples free of illicit opioids at the end of the taper and at follow-up. Findings At the end of the taper, 44% of the 7-day taper group (n = 255) provided opioid-free urine specimens compared to 30% of the 28-day taper group (n = 261; P = 0.0007). There were no differences at the 1-month and 3-month follow-ups (7-day = 18% and 12%; 28-day = 18% and 13%, 1 month and 3 months, respectively). Conclusion For individuals terminating buprenorphine pharmacotherapy for opioid dependence, there appears to be no advantage in prolonging the duration of taper. PMID:19149822

  10. Potential relationship between design of nickel-titanium rotary instruments and vertical root fracture.

    PubMed

    Kim, Hyeon-Cheol; Lee, Min-Ho; Yum, Jiwan; Versluis, Antheunis; Lee, Chan-Joo; Kim, Byung-Min

    2010-07-01

    Nickel-titanium (NiTi) rotary files can produce cleanly tapered canal shapes with low tendency of transporting the canal lumen. Because NiTi instruments are generally perceived to have high fracture risk during use, new designs have been marketed to lower fracture risks. However, these design variations may also alter the forces on a root during instrumentation and increase dentinal defects that predispose a root to fracture. This study compared the stress conditions during rotary instrumentation in a curved root for three NiTi file designs. Stresses were calculated using finite element (FE) analysis. FE models of ProFile (Dentsply Maillefer, Ballaigues, Switzerland; U-shaped cross-section and constant 6% tapered shaft), ProTaper Universal (Dentsply; convex triangular cross-section with notch and progressive taper shaft), and LightSpeed LSX (Lightspeed Technology, Inc, San Antonio, TX; noncutting round shaft) were rotated within a curved root canal. The stress and strain conditions resulting from the simulated shaping action were evaluated in the apical root dentin. ProTaper Universal induced the highest von Mises stress concentration in the root dentin and had the highest tensile and compressive principal strain components at the external root surface. The calculated stress values from ProTaper Universal, which had the biggest taper shaft, approached the strength properties of dentin. LightSpeed generated the lowest stresses. The stiffer file designs generated higher stress concentrations in the apical root dentin during shaping of the curved canal, which raises the risk of dentinal defects that may lead to apical root cracking. Thus, stress levels during shaping and fracture susceptibility after shaping vary with instrument design. Copyright 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  11. Cleaning capacity promoted by motor-driven or manual instrumentation using ProTaper Universal system: Histological analysis.

    PubMed

    da Frota, Matheus Franco; Filho, Idomeo Bonetti; Berbert, Fábio Luiz Camargo Villela; Sponchiado, Emilio Carlos; Marques, André Augusto Franco; Garcia, Lucas da Fonseca Roberti

    2013-01-01

    The aim of this study was to assess the cleaning capacity of the Protaper system using motor-driven or manual instrumentation. Ten mandibular molars were randomly separated into 2 groups (n = 5) according to the type of instrumentation performed, as follows: Group 1 - instrumentation with rotary nickel-titanium (Ni-Ti) files using ProTaper Universal System (Dentsply/Maillefer); and, Group 2 - instrumentation with Ni-Ti hand files using ProTaper Universal (Dentsply-Maillefer). Afterwards, the teeth were sectioned transversely and submitted to histotechnical processing to obtain histological sections for microscopic evaluation. The images were analyzed by the Corel Photo-Paint X5 program (Corel Corporation) using an integration grid superimposed on the image. Statistical analysis (U-Mann-Whitney - P < 0.05) demonstrated that G1 presented higher cleaning capacity when compared to G2. The rotary technique presented better cleaning results in the apical third of the root canal system when compared to the manual technique.

  12. [COMPUTER ASSISTED DESIGN AND ELECTRON BEAMMELTING RAPID PROTOTYPING METAL THREE-DIMENSIONAL PRINTING TECHNOLOGY FOR PREPARATION OF INDIVIDUALIZED FEMORAL PROSTHESIS].

    PubMed

    Liu, Hongwei; Weng, Yiping; Zhang, Yunkun; Xu, Nanwei; Tong, Jing; Wang, Caimei

    2015-09-01

    To study the feasibility of preparation of the individualized femoral prosthesis through computer assisted design and electron beammelting rapid prototyping (EBM-RP) metal three-dimensional (3D) printing technology. One adult male left femur specimen was used for scanning with 64-slice spiral CT; tomographic image data were imported into Mimics15.0 software to reconstruct femoral 3D model, then the 3D model of individualized femoral prosthesis was designed through UG8.0 software. Finally the 3D model data were imported into EBM-RP metal 3D printer to print the individualized sleeve. According to the 3D model of individualized prosthesis, customized sleeve was successfully prepared through the EBM-RP metal 3D printing technology, assembled with the standard handle component of SR modular femoral prosthesis to make the individualized femoral prosthesis. Customized femoral prosthesis accurately matching with metaphyseal cavity can be designed through the thin slice CT scanning and computer assisted design technology. Titanium alloy personalized prosthesis with complex 3D shape, pore surface, and good matching with metaphyseal cavity can be manufactured by the technology of EBM-RP metal 3D printing, and the technology has convenient, rapid, and accurate advantages.

  13. Monitoring the fabrication of tapered optical fibres

    NASA Astrophysics Data System (ADS)

    Mullaney, K.; Correia, R.; Staines, S. E.; James, S. W.; Tatam, R. P.

    2017-04-01

    A variety of optical methods to enhance the process of making optical fibre tapers are explored. A thermal camera was used to both refine the alignment of the optical components and optimize the laser power profile during the tapering process. The fibre transmission was measured to verify that the tapers had the requisite optical characteristics while the strain experienced by the fibre while tapering was assessed using an optical fibre Bragg grating. Using these techniques, adiabatic tapers were fabricated with a 2% insertion loss.

  14. Canal shaping with WaveOne Primary reciprocating files and ProTaper system: a comparative study.

    PubMed

    Berutti, Elio; Chiandussi, Giorgio; Paolino, Davide Salvatore; Scotti, Nicola; Cantatore, Giuseppe; Castellucci, Arnaldo; Pasqualini, Damiano

    2012-04-01

    This study compared the canal curvature and axis modification after instrumentation with WaveOne Primary reciprocating files (Dentsply Maillefer, Ballaigues, Switzerland) and nickel-titanium (NiTi) rotary ProTaper (Dentsply Maillefer). Thirty ISO 15, 0.02 taper, Endo Training Blocks (Dentsply Maillefer) were used. In all specimens, the glide path was achieved with PathFile 1, 2, and 3 (Dentsply Maillefer) at the working length (WL). Specimens were then assigned to 1 of 2 groups for shaping: specimens in group 1 were shaped with ProTaper S1-S2-F1-F2 at the WL and specimens in group 2 were shaped with WaveOne Primary reciprocating files at the WL. Pre- and postinstrumentation digital images were superimposed and processed with Matlab r2010b (The MathWorks Inc, Natick, MA) software to analyze the curvature-radius ratio (CRr) and the relative axis error (rAe), representing canal curvature modification. Data were analyzed with one-way balanced analyses of variance at 2 levels (P < .05). The instrument factor was extremely significant for both the CRr parameter (F(1) = 9.59, P = .004) and the rAe parameter (F(1) = 13.55, P = .001). Canal modifications are reduced when the new WaveOne NiTi single-file system is used. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  15. Long Term Survivorship of a Severely Notched Femoral Stem after Replacing the Fractured Ceramic head with a Cobalt-Chromium Head

    PubMed Central

    Panagopoulos, Andreas; Tatani, Irini; Megas, Panagiotis

    2016-01-01

    Background: Although ceramic head fracture occurs infrequently today, in the event of a fracture, the resulting revision surgery can prove very challenging, since the ceramic particles lodge into the surrounding soft tissue and can cause rapid implant failure Case Presentation: A case of long term survivorship of a severed notched femoral stem after replacing the fractured femoral head with a cobalt-chromium one is reported in a 40-year old woman with hip dysplasia who underwent an uncomplicated total hip arthroplasty. The incident of ceramic femoral head fracture occurred 14 months postoperatively without reporting any significant trauma. Intraoperative findings at revision were a multifragmented femoral head and a damaged polyethylene insert along with diffuse metallosis and excessive wear of the cone of the stem. Both the stem and the acetabular component were stable. After removal of ceramic fragments, metallotic tissue excision and careful lavage of the joint, the inlay was replaced by a similar one and a cobalt-chromium femoral head was placed to the existing notched taper of the firmly incorporated stem. At the 13th year follow up examination, the patient had no pain, used no walking aids, and had normal activity with no signs of wearing or loosening in the plain x-rays. Conclusion: Despite current recommendations of using ceramic femoral heads in cases of fracture or to revise the severely damaged stems we were able to provide a long term survivorship up to 13 years postoperatively of a cobalt-chromium femoral head applied to a severe damaged stem. PMID:28217203

  16. Long Term Survivorship of a Severely Notched Femoral Stem after Replacing the Fractured Ceramic head with a Cobalt-Chromium Head.

    PubMed

    Panagopoulos, Andreas; Tatani, Irini; Megas, Panagiotis

    2016-01-01

    Although ceramic head fracture occurs infrequently today, in the event of a fracture, the resulting revision surgery can prove very challenging, since the ceramic particles lodge into the surrounding soft tissue and can cause rapid implant failure. A case of long term survivorship of a severed notched femoral stem after replacing the fractured femoral head with a cobalt-chromium one is reported in a 40-year old woman with hip dysplasia who underwent an uncomplicated total hip arthroplasty. The incident of ceramic femoral head fracture occurred 14 months postoperatively without reporting any significant trauma. Intraoperative findings at revision were a multifragmented femoral head and a damaged polyethylene insert along with diffuse metallosis and excessive wear of the cone of the stem. Both the stem and the acetabular component were stable. After removal of ceramic fragments, metallotic tissue excision and careful lavage of the joint, the inlay was replaced by a similar one and a cobalt-chromium femoral head was placed to the existing notched taper of the firmly incorporated stem. At the 13 th year follow up examination, the patient had no pain, used no walking aids, and had normal activity with no signs of wearing or loosening in the plain x-rays. Despite current recommendations of using ceramic femoral heads in cases of fracture or to revise the severely damaged stems we were able to provide a long term survivorship up to 13 years postoperatively of a cobalt-chromium femoral head applied to a severe damaged stem.

  17. Laboratory comparison of the mechanical properties of TRUShape with several nickel-titanium rotary instruments.

    PubMed

    Elnaghy, A M; Elsaka, S E

    2017-08-01

    To assess and compare the mechanical properties of TRUShape (TRS) with several nickel-titanium rotary instruments. Cyclic fatigue, torsional resistance, flexibility and surface microhardness of TRS (size 25, 0.06v taper), ProTaper Next X2 (PTN X2, size 25, 0.06 taper), ProTaper Gold (PTG F2; size 25, 0.08 taper) and ProTaper Universal (PTU F2; size 25, 0.08 taper) instruments were evaluated. The topographical structures of the fracture surfaces of instruments were assessed using a scanning electron microscope. The cyclic fatigue resistance, torsional resistance and microhardness data were analysed using one-way analysis of variance (anova) and Tukey's post hoc tests. The fragment length and bending resistance data were analysed statistically with the Kruskal-Wallis H-test and Mann-Whitney U-tests. The statistical significance level was set at P < 0.05. PTN and PTG instruments revealed significantly higher resistance to cyclic fatigue than TRS and PTU instruments (P < 0.001). PTN instruments revealed significantly higher torsional resistance compared with the other instruments (P < 0.001). PTG instrument had significantly higher flexibility than the other tested brands (P < 0.05). However, for microhardness, the PTU had significantly higher surface microhardness values compared with other tested brands (P < 0.05). TRS instruments had lower resistance to cyclic fatigue and lower flexibility compared with PTG and PTN instruments. TRS, PTG and PTU instruments had lower resistance to torsional stress than PTN instruments. TRS and PTG instruments had comparable surface microhardness. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  18. In vitro evaluation of the effectiveness of ProTaper universal rotary retreatment system for gutta-percha removal with or without a solvent.

    PubMed

    Takahashi, Cristiane Midori; Cunha, Rodrigo Sanches; de Martin, Alexandre Sigrist; Fontana, Carlos Eduardo; Silveira, Cláudia Fernandes M; da Silveira Bueno, Carlos Eduardo

    2009-11-01

    Effective removal of gutta-percha in endodontic retreatment is a significant factor to ensure a favorable outcome from failed procedures. The purpose of this study was to evaluate the efficacy of a nickel-titanium rotary instrument system with or without a solvent versus stainless steel hand files for gutta-percha removal. Forty extracted human maxillary anterior teeth were prepared and filled. They were divided into 4 groups: Gates-Glidden and K-files, Gates-Glidden and K-files with chloroform, ProTaper Universal rotary retreatment system, and ProTaper Universal rotary retreatment system with chloroform. The operating time was recorded. The teeth were longitudinally sectioned and photographed. The images were analyzed and the filling remnants were quantified by using the IMAGE TOOL software. With Kruskall-Wallis test, statistical analysis showed that there was no significant difference between the techniques in regard to the amount of the endodontic filling remnants (P < .05); however, the ProTaper Universal rotary retreatment system was faster than the hand files (P < .05). All of the techniques proved helpful for the removal of endodontic filling material, and they were similar in material remaining after retreatment, but the ProTaper Universal rotary retreatment system without chloroform was faster.

  19. Tapering Practices of Croatian Open-Class Powerlifting Champions.

    PubMed

    Grgic, Jozo; Mikulic, Pavle

    2017-09-01

    Grgic, J and Mikulic, P. Tapering practices of Croatian open-class powerlifting champions. J Strength Cond Res 31(9): 2371-2378, 2017-The aim of this study was to explore tapering practices among 10 Croatian open-class powerlifting champions (mean ± SD: age 29.2 ± 3.2 years; Wilks coefficient 355.1 ± 54.8). The athletes were interviewed about their tapering practices using a semi-structured interview after which the audio content was transcribed. The athletes reported decreasing training volume during the taper by 50.5 ± 11.7% using a step type or an exponential type of taper with a fast decay. Training intensity was maintained or increased during the taper, and it reached its highest values 8 ± 3 days before the competition. Training frequency was reduced or maintained during the taper. The final week included a reduction in training frequency by 47.9 ± 17.5% with the last training session performed 3 ± 1 days before the competition. The participants typically stated that the main reasons for conducting the taper were maintaining strength and reducing the amount of fatigue. They also stated that (a) the taper was structured identically for the squat, bench press, and the deadlift; (b) the training during the taper was highly specific, the assistance exercises were removed, and the same equipment was used as during competition; (c) the source of information for tapering was their coach, and training fluctuated based on the coach's feedback; and (d) nutrition, foam rolling, static stretching, and massage were all given extra attention during the taper. These results may aid athletes and coaches in strength sports in terms of the optimization of tapering variables.

  20. Pseudotumor Caused by Titanium Particles From a Total Hip Prosthesis.

    PubMed

    Sakamoto, Masaaki; Watanabe, Hitoshi; Higashi, Hidetaka; Kubosawa, Hitoshi

    2016-01-01

    A 77-year-old woman underwent metal-on-polyethylene total hip arthroplasty for osteoarthritis of the right hip at another institution. During surgery, the greater trochanter was broken and internal fixation was performed with a trochanteric cable grip reattachment. Although postoperative recovery was uneventful, approximately 6 years later, the patient had severe right hip pain with apparent swelling, and she was referred to the authors' institution. Plain radiographs showed evidence of severe osteolysis in the proximal femur and cable breakage; however, preoperative aspiration culture findings were negative for bacterial growth. Magnetic resonance imaging showed a well-circumscribed mass, presumed to be a pseudotumor. Serum cobalt and chromium levels were within normal limits, and the serum titanium level was high. During surgery, the mass was excised and removal of the cable system revealed a sharp deficit in the bare femoral stem. Gross surgical findings showed no obvious evidence of infection and no corrosion at the head-neck junction; therefore, all components were retained besides the cable system, which resulted in clinical recovery. All of the cultures from specimens were negative for bacterial growth, and histologic findings were compatible with a pseudotumor, such as histiocytes containing metal particles, abundant plasma cells, and CD8-positive cells. Quantitative analysis by inductively coupled plasma atomic emission spectrometry showed that the main source of metal debris in the pseudotumor was the femoral stem, which was made of titanium alloy, not the broken cable, which was made of cobalt-chromium alloy. The findings suggest that titanium particles can form symptomatic solid pseudotumors. Copyright 2016, SLACK Incorporated.

  1. Comparative evaluation of apically extruded debris with V-Taper, ProTaper Next, and the Self-adjusting File systems.

    PubMed

    Vyavahare, Nishant K; Raghavendra, Srinidhi Surya; Desai, Niranjan N

    2016-01-01

    Complete cleaning of the root canal is the goal for ensuring success in endodontics. Removal of debris plays an important role in achieving this goal. In spite of advancements in instrument design, apical extrusion of debris remains a source of inflammation in the periradicular region. To comparatively evaluate the amount of apically extruded debris with V-Taper, ProTaper Next, and the self-adjusting File (SAF) system. Sixty-four extracted human mandibular teeth with straight root canals were taken. Access openings were done and working length determined. The samples were randomly divided into three groups: Group I - V-Taper files (n = 20), Group II - ProTaper Next (n = 20), Group III - SAF (n = 20). Biomechanical preparation was completed and the debris collected in vials to be quantitatively determined. The data obtained was statistically analyzed using ANOVA and post hoc Tukey's test. All the specimens showed apical debris extrusion. SAF showed significantly less debris extrusion compared to V-Taper and ProTaper Next (P < 0.001). Among Groups I and II, ProTaper Next showed lesser debris extrusion as compared to V-Taper, but it was not significant (P = 0.124). The SAF showed least amount of apical debris extrusion when compared to newer rotary endodontic instruments. This indicates that the incidence of inter-treatment flare-ups due to debris extrusion would be less with the SAF.

  2. The efficacy of ProTaper Universal rotary retreatment instrumentation to remove single gutta-percha cones cemented with several endodontic sealers.

    PubMed

    Ersev, H; Yilmaz, B; Dinçol, M E; Dağlaroğlu, R

    2012-08-01

    To evaluate residual root filling material following removal of three newly developed root canal sealers used with a matched-taper single-cone root filling technique and to compare the efficacy of ProTaper Universal rotary retreatment instruments with that of a conventional manual technique. The canals of 120 palatal roots in maxillary molar teeth were instrumented with EndoWave nickel-titanium rotary instruments and filled using Hybrid Root SEAL, EndoSequence BC Sealer, Activ GP system or AH Plus with matched-taper single gutta-percha cones. The root fillings were then removed with ProTaper Universal retreatment rotary instruments or a manual technique. Buccolingual and proximal digital radiographs of the roots were exposed to determine the area of remaining filling material in the coronal, middle and apical thirds. The area percentages of remaining filling material in each third and total canal area were calculated. Data were analysed statistically with Kruskal-Wallis and Mann-Whitney U-tests. The level of significance was set at P<0.05. Irrespective of the sealer type and retreatment technique, filling material could not be removed completely from the root canals. Significantly, more remaining filling material was observed in the apical third (P<0.05). When comparing the sealers, the only significant difference was detected between AH Plus/manual and Activ GP/manual groups with respect to residual material in the total canal area (P<0.05). There were no significant differences between manual and ProTaper groups. When using gross radiographic criteria, the Activ GP was more effectively removed from root canals than AH Plus with hand instrumentation. Hybrid Root SEAL, EndoSequence BC Sealer and AH Plus were removed to a similar extent. ProTaper Universal retreatment instruments were as safe and effective as hand instruments in reaching the working length. © 2012 International Endodontic Journal.

  3. Supercontinuum generation in a tapered tellurite microstructured optical fiber

    NASA Astrophysics Data System (ADS)

    Yan, X.; Ohishi, Y.

    2014-07-01

    Supercontinuum generation (SCG) was investigated in tapered tellurite microstructured optical fibers (MOFs) for various taper profiles. We emphasize on the procedure for finding the dispersion profile that achieve the best width of the SC spectra. An enhancement of the SCG is achieved by varying the taper waist diameter along its length in a carefully designed, and an optimal degree of tapering is found to exist for tapers with an axially uniform waist. We also show the XFROG spectrograms of the pulses propagating through different tapered fibers, confirming the optimized taper conditions.

  4. Tapered undulator for SASE FELs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fawley, William M.; Huang, Zhirong; Kim, Kwang-Je

    We discuss the use of tapered undulators to enhance the performance of free-electron lasers (FELs) based upon self-amplified spontaneous emission (SASE), where the radiation tends to have a relatively broad bandwidth, limited temporal phase coherence, and large amplitude fluctuations. Using the polychromatic FEL simulation code GINGER, we numerically demonstrate the effectiveness of a tapered undulator for parameters corresponding to the existing Argonne low-energy undulator test line (LEUTL) FEL. We also study possible tapering options for proposed x-ray FELs such as the Linac Coherent Light Source (LCLS).

  5. Comparative evaluation of cyclic fatigue resistance of D-RaCe and ProTaper retreatment instruments in curved artificial canals.

    PubMed

    Topçuoğlu, H S; Topçuoğlu, G; Aktı, A

    2016-06-01

    To compare the cyclic fatigue resistance of D-RaCe and ProTaper rotary nickel-titanium (NiTi) retreatment files when used in curved artificial canals. A total of 120 new D-RaCe DR2 and ProTaper D3 retreatment files were tested in stainless steel artificial canals having 45° and 60° angles of curvature. Thirty instruments of each of the file systems were tested in both angles of curvature (n = 30). The retreatment instruments were rotated until fracture to calculate the number of cycles to failure. The length of each fractured fragment was recorded. Data were analysed by independent sample t-test. Fractured surfaces of the instruments were analysed by scanning electron microscopy. In the canal with 45° angle of curvature, no significant difference was observed between the retreatment systems (P > 0.05); on the other hand, in the canal with 60° angle of curvature, D-RaCe DR2 instruments had greater cyclic fatigue resistance than ProTaper D3 (P < 0.05). No difference was observed between the retreatment instruments regarding the lengths of fractured fragments (P > 0.05). The fracture surfaces of the instruments had morphologic characteristics of ductile fracture. D-RaCe DR2 instrument exhibited greater cyclic fatigue resistance than ProTaper D3 only in root canals with 60° angle of curvature. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  6. Comparative evaluation of apically extruded debris with V-Taper, ProTaper Next, and the Self-adjusting File systems

    PubMed Central

    Vyavahare, Nishant K.; Raghavendra, Srinidhi Surya; Desai, Niranjan N.

    2016-01-01

    Background: Complete cleaning of the root canal is the goal for ensuring success in endodontics. Removal of debris plays an important role in achieving this goal. In spite of advancements in instrument design, apical extrusion of debris remains a source of inflammation in the periradicular region. Aim: To comparatively evaluate the amount of apically extruded debris with V-Taper, ProTaper Next, and the self-adjusting File (SAF) system. Materials and Methods: Sixty-four extracted human mandibular teeth with straight root canals were taken. Access openings were done and working length determined. The samples were randomly divided into three groups: Group I - V-Taper files (n = 20), Group II - ProTaper Next (n = 20), Group III - SAF (n = 20). Biomechanical preparation was completed and the debris collected in vials to be quantitatively determined. The data obtained was statistically analyzed using ANOVA and post hoc Tukey's test. Results: All the specimens showed apical debris extrusion. SAF showed significantly less debris extrusion compared to V-Taper and ProTaper Next (P < 0.001). Among Groups I and II, ProTaper Next showed lesser debris extrusion as compared to V-Taper, but it was not significant (P = 0.124). Conclusion: The SAF showed least amount of apical debris extrusion when compared to newer rotary endodontic instruments. This indicates that the incidence of inter-treatment flare-ups due to debris extrusion would be less with the SAF. PMID:27217636

  7. Tapered enlarged ends in multimode optical fibers.

    PubMed

    Brenci, M; Falciai, R; Scheggi, A M

    1982-01-15

    Radiation characteristics of multimode fibers with enlarged tapers were investigated on a number of samples obtained by varying the fiber drawing speed with a given law corresponding to a prefixed taper profile. The characterization of the fibers was made by near- and far-field intensity pattern measurements as well as by measuring the losses introduced by the taper. With a suitable choice of parameters the taper constitutes a reasonable low-loss component useful, for example, for either efficient coupling to large-spot high-power density sources or connecting fibers of different sizes. Conversely at the exit of the fiber the taper can be used for beam shaping which is of interest for mechanical or surgical applications.

  8. Large Diameter Femoral Heads Impose Significant Alterations on the Strains Developed on Femoral Component and Bone: A Finite Element Analysis

    PubMed Central

    Theodorou, E.G; Provatidis, C.G; Babis, G.C; Georgiou, C.S; Megas, P.D

    2011-01-01

    Total Hip Arthroplasty aims at fully recreating a functional hip joint. Over the past years modular implant systems have become common practice and are widely used, due to the surgical options they provide. In addition Big Femoral Heads have also been implemented in the process, providing more flexibility for the surgeon. The current study aims at investigating the effects that femoral heads of bigger diameter may impose on the mechanical behavior of the bone-implant assembly. Using data acquired by Computed Tomographies and a Coordinate Measurement Machine, a cadaveric femur and a Profemur-E modular stem were fully digitized, leading to a three dimensional finite element model in ANSYS Workbench. Strains and stresses were then calculated, focusing on areas of clinical interest, based on Gruen zones: the calcar and the corresponding below the greater trochanter area in the proximal femur, the stem tip region and a profile line along linea aspera. The performed finite elements analysis revealed that the use of large diameter heads produces significant changes in strain development within the bone volume, especially in the lateral side. The application of Frost’s law in bone remodeling, validated the hypothesis that for all diameters normal bone growth occurs. However, in the calcar area lower strain values were recorded, when comparing with the reference model featuring a 28mm femoral head. Along line aspera and for the stem tip area, higher values were recorded. Finally, stresses calculated on the modular neck revealed increased values, but without reaching the yield strength of the titanium alloy used. PMID:21792381

  9. Large diameter femoral heads impose significant alterations on the strains developed on femoral component and bone: a finite element analysis.

    PubMed

    Theodorou, E G; Provatidis, C G; Babis, G C; Georgiou, C S; Megas, P D

    2011-01-01

    Total Hip Arthroplasty aims at fully recreating a functional hip joint. Over the past years modular implant systems have become common practice and are widely used, due to the surgical options they provide. In addition Big Femoral Heads have also been implemented in the process, providing more flexibility for the surgeon. The current study aims at investigating the effects that femoral heads of bigger diameter may impose on the mechanical behavior of the bone-implant assembly. Using data acquired by Computed Tomographies and a Coordinate Measurement Machine, a cadaveric femur and a Profemur-E modular stem were fully digitized, leading to a three dimensional finite element model in ANSYS Workbench. Strains and stresses were then calculated, focusing on areas of clinical interest, based on Gruen zones: the calcar and the corresponding below the greater trochanter area in the proximal femur, the stem tip region and a profile line along linea aspera. The performed finite elements analysis revealed that the use of large diameter heads produces significant changes in strain development within the bone volume, especially in the lateral side. The application of Frost's law in bone remodeling, validated the hypothesis that for all diameters normal bone growth occurs. However, in the calcar area lower strain values were recorded, when comparing with the reference model featuring a 28mm femoral head. Along line aspera and for the stem tip area, higher values were recorded. Finally, stresses calculated on the modular neck revealed increased values, but without reaching the yield strength of the titanium alloy used.

  10. Electrochemical impedance spectroscopy investigation on the clinical lifetime of ProTaper rotary file system.

    PubMed

    Penta, Virgil; Pirvu, Cristian; Demetrescu, Ioana

    2014-01-01

    The main objective of the current paper is to show that electrochemical impedance spectroscopy (EIS) could be a method for evaluating and predicting of ProTaper rotary file system clinical lifespan. This particular aspect of everyday use of the endodontic files is of great importance in each dental practice and has profound clinical implications. The method used for quantification resides in the electrochemical impedance spectroscopy theory and has in its main focus the characteristics of the surface titanium oxide layer. This electrochemical technique has been adapted successfully to identify the quality of the Ni-Ti files oxide layer. The modification of this protective layer induces changes in corrosion behavior of the alloy modifying the impedance value of the file. In order to assess the method, 14 ProTaper sets utilized on different patients in a dental clinic have been submitted for testing using EIS. The information obtained in regard to the surface oxide layer has offered an indication of use and proves that the said layer evolves with each clinical application. The novelty of this research is related to an electrochemical technique successfully adapted for Ni-Ti file investigation and correlation with surface and clinical aspects.

  11. Root canal volume change and transportation by Vortex Blue, ProTaper Next, and ProTaper Universal in curved root canals

    PubMed Central

    2018-01-01

    Objectives The aim of this study was to compare root canal volume change and canal transportation by Vortex Blue (VB; Dentsply Tulsa Dental Specialties), ProTaper Next (PTN; Dentsply Maillefer), and ProTaper Universal (PTU; Dentsply Maillefer) nickel-titanium rotary files in curved root canals. Materials and Methods Thirty canals with 20°–45° of curvature from extracted human molars were used. Root canal instrumentation was performed with VB, PTN, and PTU files up to #30.06, X3, and F3, respectively. Changes in root canal volume before and after the instrumentation, and the amount and direction of canal transportation at 1, 3, and 5 mm from the root apex were measured by using micro-computed tomography. Data of canal volume change were statistically analyzed using one-way analysis of variance and Tukey test, while data of amount and direction of transportation were analyzed using Kruskal-Wallis and Mann-Whitney U test. Results There were no significant differences among 3 groups in terms of canal volume change (p > 0.05). For the amount of transportation, PTN showed significantly less transportation than PTU at 3 mm level (p = 0.005). VB files showed no significant difference in canal transportation at all 3 levels with either PTN or PTU files. Also, VB files showed unique inward transportation tendency in the apical area. Conclusions Other than PTN produced less amount of transportation than PTU at 3 mm level, all 3 file systems showed similar level of canal volume change and transportation, and VB file system could prepare the curved canals without significant shaping errors. PMID:29487834

  12. An evaluation of flexible intramedullary nail fixation in femoral shaft fractures in paediatric age group.

    PubMed

    Kumar, Sanjay; Roy, Sandip Kumar; Jha, Amrish Kumar; Chatterjee, Debdutta; Banerjee, Debabrata; Garg, Anant Kumar

    2011-06-01

    Sixty-two femoral shaft fractures in 60 patients treated by elastic intramedullary nailing with mean age of the patients being 9.2 years (range 5 years to 12 years) and average follow-up of 15 months (range 7 months to 60 months) are evaluated. Twenty-eight fractures were fixed with titanium elastic nail while 34 fractures were fixed with Enders nail. There were 40 midshaft fractures, 18 proximal femoral and 4 were fractures of distal third. Fracture patterns were transverse in 35, short oblique in 14 cases and 13 were spiral fractures. Mean age of union in this series was 17 weeks (range 12 weeks to 28 weeks). Ten cases had complications, 5 had nail tip irritation, 3 varus or valgus malalignment and 2 had delayed union. In this series, we did not have any non-union, refracture, limb length discrepancy or any major infection. The result demonstrates 100% union rate irrespective of the age, weight and height of the patient. Regardless of the site of fracture and their pattern, it united every time with elastic nail fixation. We did not find and mismatch in the results of fractures stabilised with titanium elastic nail with that of elastic stainless steel nail.

  13. Prospective evaluation of femoral head viability following femoral neck fracture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Binkert, B.; Kroop, S.A.; Nepola, I.V.

    1984-01-01

    The bone scans of 33 patients (pts) with recent subcapital fractures (fx) of the femur were evaluated prospectively to determine their value in predicting femoral head visability. Each of the 33 pts (ll men, 22 women, age range 30-92) had a pre-operative bone scan within 72 hrs of the fx (23 pts within 24 hrs). Anterior and posterior planar views of both hips and pinhole views (50% of pts) were obtained 2 hrs after administration of Tc-99m HDP. The femoral head was classified as perfused if it showed the same activity as the opposite normal side or if it showedmore » only slightly decreased activity. Femoral heads showing absent activity were classified as nonperfused. Overall, 20 of the 33 pts showed a photopenic femoral head on the side of the fx. Only 2 pts showed increased activity at hte site of the fx. Internal fixation of the fx was performed in 23 pts, 12 of whom had one or more follow-up scans. Five of these 12 pts showed absent femoral head activity on their initial scan, but 2 showed later reperfusion. The other 7 pts showed good perfusion initially, with only 1 later showing decreased femoral head activity. The other 10 pts (7 of whom had absent femoral head activity) had immediate resection of the femoral head and insertion of a Cathcart prosthesis. The results suggest that femoral head activity seen on a bone scan in the immediate post-fx period is not always a reliable indicator of femoral head viability. Decreased femoral head activity may reflect, in part, compromised perfusion secondary to post-traumatic edema, with or without anatomic disruption of the blood supply.« less

  14. 2D constant-loss taper for mode conversion

    NASA Astrophysics Data System (ADS)

    Horth, Alexandre; Kashyap, Raman; Quitoriano, Nathaniel J.

    2015-03-01

    Proposed in this manuscript is a novel taper geometry, the constant-loss taper (CLT). This geometry is derived with 1D slabs of silicon embedded in silicon dioxide using coupled-mode theory (CMT). The efficiency of the CLT is compared to both linear and parabolic tapers using CMT and 2D finite-difference time-domain simulations. It is shown that over a short 2D, 4.45 μm long taper the CLT's mode conversion efficiency is ~90% which is 10% and 18% more efficient than a 2D parabolic or linear taper, respectively.

  15. Soliton propagation in tapered silicon core fibers.

    PubMed

    Peacock, Anna C

    2010-11-01

    Numerical simulations are used to investigate soliton-like propagation in tapered silicon core optical fibers. The simulations are based on a realistic tapered structure with nanoscale core dimensions and a decreasing anomalous dispersion profile to compensate for the effects of linear and nonlinear loss. An intensity misfit parameter is used to establish the optimum taper dimensions that preserve the pulse shape while reducing temporal broadening. Soliton formation from Gaussian input pulses is also observed--further evidence of the potential for tapered silicon fibers to find use in a range of signal processing applications.

  16. Endodontic complications of root canal therapy performed by dental students with stainless-steel K-files and nickel-titanium hand files.

    PubMed

    Pettiette, M T; Metzger, Z; Phillips, C; Trope, M

    1999-04-01

    Straightening of curved canals is one of the most common procedural errors in endodontic instrumentation. This problem is commonly encountered when dental students perform molar endodontics. The purpose of this study was to compare the effect of the type of instrument used by these students on the extent of straightening and on the incidence of other endodontic procedural errors. Nickel-titanium 0.02 taper hand files were compared with traditional stainless-steel 0.02 taper K-files. Sixty molar teeth comprised of maxillary and mandibular first and second molars were treated by senior dental students. Instrumentation was with either nickel-titanium hand files or stainless-steel K-files. Preoperative and postoperative radiographs of each tooth were taken using an XCP precision instrument with a customized bite block to ensure accurate reproduction of radiographic angulation. The radiographs were scanned and the images stored as TIFF files. By superimposing tracings from the preoperative over the postoperative radiographs, the degree of deviation of the apical third of the root canal filling from the original canal was measured. The presence of other errors, such as strip perforation and instrument breakage, was established by examining the radiographs. In curved canals instrumented by stainless-steel K-files, the average deviation of the apical third of the canals was 14.44 degrees (+/- 10.33 degrees). The deviation was significantly reduced when nickel-titanium hand files were used to an average of 4.39 degrees (+/- 4.53 degrees). The incidence of other procedural errors was also significantly reduced by the use of nickel-titanium hand files.

  17. Tapering strategies in elite British endurance runners.

    PubMed

    Spilsbury, Kate L; Fudge, Barry W; Ingham, Stephen A; Faulkner, Steve H; Nimmo, Myra A

    2015-01-01

    The aim of the study was to explore pre-competition training practices of elite endurance runners. Training details from elite British middle distance (MD; 800 m and 1500 m), long distance (LD; 3000 m steeplechase to 10,000 m) and marathon (MAR) runners were collected by survey for 7 days in a regular training (RT) phase and throughout a pre-competition taper. Taper duration was [median (interquartile range)] 6 (3) days in MD, 6 (1) days in LD and 14 (8) days in MAR runners. Continuous running volume was reduced to 70 (16)%, 71 (24)% and 53 (12)% of regular levels in MD, LD and MAR runners, respectively (P < 0.05). Interval running volume was reduced compared to regular training (MD; 53 (45)%, LD; 67 (23)%, MAR; 64 (34)%, P < 0.05). During tapering, the peak interval training intensity was above race speed in LD and MAR runners (112 (27)% and 114 (3)%, respectively, P < 0.05), but not different in MD (100 (2)%). Higher weekly continuous running volume and frequency in RT were associated with greater corresponding reductions during the taper (R = -0.70 and R = -0.63, respectively, both P < 0.05). Running intensity during RT was positively associated with taper running intensity (continuous intensity; R = 0.97 and interval intensity; R = 0.81, both P < 0.05). Algorithms were generated to predict and potentially prescribe taper content based on the RT of elite runners. In conclusion, training undertaken prior to the taper in elite endurance runners is predictive of the tapering strategy implemented before competition.

  18. Patello-femoral and tibio-femoral contact forces during kicking type of activity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engin, A.E.; Tumer, S.T.

    1996-12-31

    In this paper patello-femoral and tibia-femoral contact forces during kicking type of activity is presented by means of a dynamic model of the knee joint which includes tibio-femoral and patello-femoral articulations, and the major ligaments of the joint. The model shows that the patella can be subjected to very large transient patello-femoral contact forces during a strenuous lower limb activity such as kicking even under conditions of small knee-flexion angles.

  19. Tapered waveguides for guided wave optics.

    PubMed

    Campbell, J C

    1979-03-15

    Strip waveguides having half-paraboloid shaped tapers that permit efficient fiber to waveguide coupling have been fabricated by Ag ion exchange in soda-lime glass. A reduction in the input coupling loss has been accomplished by tailoring the diffusion to provide a gradual transition from a single-mode waveguide to a multimode waveguide having cross-sectional dimensions comparable to the core diameter of a single-mode fiber. Waveguides without tapers exhibit an attenuation of 1.0 dB/cm and an input coupling loss of 0.6 dB. The additional loss introduced by the tapered region is 0.5 dB. By way of contrast, an input coupling loss of 2.4 dB is obtained by coupling directly to a single-mode waveguide, indicating a net improvement of 1.3 dB for the tapered waveguides.

  20. Hand and nickel-titanium root canal instrumentation performed by dental students: a micro-computed tomographic study.

    PubMed

    Peru, M; Peru, C; Mannocci, F; Sherriff, M; Buchanan, L S; Pitt Ford, T R

    2006-02-01

    The aim of this study was to evaluate root canals instrumented by dental students using the modified double-flared technique, nickel-titanium (NiTi) rotary System GT files and NiTi rotary ProTaper files by micro-computed tomography (MCT). A total of 36 root canals from 18 mesial roots of mandibular molar teeth were prepared; 12 canals were prepared with the modified double-flared technique, using K-flexofiles and Gates-Glidden burs; 12 canals were prepared using System GT and 12 using ProTaper rotary files. Each root was scanned using MCT preoperatively and postoperatively. At the coronal and mid-root sections, System GT and ProTaper files produced significantly less enlarged canal cross-sectional area, volume and perimeter than the modified double-flared technique (P < 0.05). In the mid-root sections there was significantly less thinning of the root structure towards the furcation with System GT and ProTaper (P < 0.05). The rotary techniques were both three times faster than the modified double-flared technique (P < 0.05). Qualitative evaluation of the preparations showed that both ProTaper and System GT were able to prepare root canals with little or no procedural error compared with the modified double-flared technique. Under the conditions of this study, inexperienced dental students were able to prepare curved root canals with rotary files with greater preservation of tooth structure, low risk of procedural errors and much quicker than with hand instruments.

  1. Femoral neck shortening after internal fixation of a femoral neck fracture.

    PubMed

    Zielinski, Stephanie M; Keijsers, Noël L; Praet, Stephan F E; Heetveld, Martin J; Bhandari, Mohit; Wilssens, Jean Pierre; Patka, Peter; Van Lieshout, Esther M M

    2013-07-01

    This study assesses femoral neck shortening and its effect on gait pattern and muscle strength in patients with femoral neck fractures treated with internal fixation. Seventy-six patients from a multicenter randomized controlled trial participated. Patient characteristics and Short Form 12 and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores were collected. Femoral neck shortening, gait parameters, and maximum isometric forces of the hip muscles were measured and differences between the fractured and contralateral leg were calculated. Variables of patients with little or no shortening, moderate shortening, and severe shortening were compared using univariate and multivariate analyses. Median femoral neck shortening was 1.1 cm. Subtle changes in gait pattern, reduced gait velocity, and reduced abductor muscle strength were observed. Age, weight, and Pauwels classification were risk factors for femoral neck shortening. Femoral neck shortening decreased gait velocity and seemed to impair gait symmetry and physical functioning. In conclusion, internal fixation of femoral neck fractures results in permanent physical limitations. The relatively young and healthy patients in our study seem capable of compensating. Attention should be paid to femoral neck shortening and proper correction with a heel lift, as inadequate correction may cause physical complaints and influence outcome. Copyright 2013, SLACK Incorporated.

  2. Femoral head wedge resection for the treatment of avascular necrosis of the femoral head after pediatric femoral neck fracture: a case report.

    PubMed

    Kim, Ha Yong; Cha, Yong Han; Choy, Won Sik; Jeung, Sang Wook; Min, Yeon Seung

    2018-05-01

    This research focuses on femoral head wedge resection for the treatment of avascular necrosis (AVN) of the femoral head. A 9-year-old girl presented to the emergency room complaining of right hip pain that occurred after a pedestrian car accident. After 8 months of internal fixation using cannulated screws for Delbet-type 2 fracture of the femoral neck, AVN of the femoral head developed in the patient. Even though valgus-derotation-extension intertrochanteric osteotomy was performed for the treatment of AVN, it progressed further and femoral head wedge resection was performed to recover the femoral head sphericity. After 3 years of follow-up, radiograph results showed appropriate and satisfactory congruency and containment. This research shows that the treatment of AVN of the femoral head using femoral head wedge resection is an effective method that can yield excellent results.

  3. Surface Functionalization of Orthopedic Titanium Implants with Bone Sialoprotein

    PubMed Central

    Ritz, Ulrike; Ackermann, Angelika; Anthonissen, Joris; Kaufmann, Kerstin B.; Brendel, Christian; Götz, Hermann; Rommens, Pol M.; Hofmann, Alexander

    2016-01-01

    Orthopedic implant failure due to aseptic loosening and mechanical instability remains a major problem in total joint replacement. Improving osseointegration at the bone-implant interface may reduce micromotion and loosening. Bone sialoprotein (BSP) has been shown to enhance bone formation when coated onto titanium femoral implants and in rat calvarial defect models. However, the most appropriate method of BSP coating, the necessary level of BSP coating, and the effect of BSP coating on cell behavior remain largely unknown. In this study, BSP was covalently coupled to titanium surfaces via an aminosilane linker (APTES), and its properties were compared to BSP applied to titanium via physisorption and untreated titanium. Cell functions were examined using primary human osteoblasts (hOBs) and L929 mouse fibroblasts. Gene expression of specific bone turnover markers at the RNA level was detected at different intervals. Cell adhesion to titanium surfaces treated with BSP via physisorption was not significantly different from that of untreated titanium at any time point, whereas BSP application via covalent coupling caused reduced cell adhesion during the first few hours in culture. Cell migration was increased on titanium disks that were treated with higher concentrations of BSP solution, independent of the coating method. During the early phases of hOB proliferation, a suppressive effect of BSP was observed independent of its concentration, particularly when BSP was applied to the titanium surface via physisorption. Although alkaline phosphatase activity was reduced in the BSP-coated titanium groups after 4 days in culture, increased calcium deposition was observed after 21 days. In particular, the gene expression level of RUNX2 was upregulated by BSP. The increase in calcium deposition and the stimulation of cell differentiation induced by BSP highlight its potential as a surface modifier that could enhance the osseointegration of orthopedic implants. Both

  4. Torsion and bending properties of shape memory and superelastic nickel-titanium rotary instruments.

    PubMed

    Ninan, Elizabeth; Berzins, David W

    2013-01-01

    Recently introduced into the market are shape memory nickel-titanium (NiTi) rotary files. The objective of this study was to investigate the torsion and bending properties of shape memory files (CM Wire, HyFlex CM, and Phoenix Flex) and compare them with conventional (ProFile ISO and K3) and M-Wire (GT Series X and ProFile Vortex) NiTi files. Sizes 20, 30, and 40 (n = 12/size/taper) of 0.02 taper CM Wire, Phoenix Flex, K3, and ProFile ISO and 0.04 taper HyFlex CM, ProFile ISO, GT Series X, and Vortex were tested in torsion and bending per ISO 3630-1 guidelines by using a torsiometer. All data were statistically analyzed by analysis of variance and the Tukey-Kramer test (P = .05) to determine any significant differences between the files. Significant interactions were present among factors of size and file. Variability in maximum torque values was noted among the shape memory files brands, sometimes exhibiting the greatest or least torque depending on brand, size, and taper. In general, the shape memory files showed a high angle of rotation before fracture but were not statistically different from some of the other files. However, the shape memory files were more flexible, as evidenced by significantly lower bending moments (P < .008). Shape memory files show greater flexibility compared with several other NiTi rotary file brands. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  5. Carbon/PEEK composite materials as an alternative for stainless steel/titanium hip prosthesis: a finite element study.

    PubMed

    Rezaei, Farshid; Hassani, Kamran; Solhjoei, Nosratollah; Karimi, Alireza

    2015-12-01

    Total hip replacement (THR) has been ranked within the most typical surgical processes in the world. The durability of the prosthesis and loosening of prosthesis are the main concerns that mostly reported after THR surgeries. In THR, the femoral prosthesis can be fixed by either cement or cementless methods in the patient's bones. In both procedures, the stability of the prosthesis in the hosted bone has a key asset in its long-term durability and performance. This study aimed to execute a comparative finite element simulation to assess the load transfer between the prosthesis, which is made of carbon/PEEK composite and stainless steel/titanium, and the femur bone. The mechanical behavior of the cortical bone was assumed as a linear transverse isotropic while the spongy bone was modeled like a linear isotropic material. The implants were made of stainless steel (316L) and titanium alloy as they are common materials for implants. The results showed that the carbon/PEEK composites provide a flatter load transfer from the upper body to the leg compared to the stainless steel/titanium prosthesis. Furthermore, the results showed that the von Mises stress, principal stress, and the strain in the carbon/PEEK composites prosthesis were significantly lower than that made of the stainless steel/titanium. The results also imply that the carbon/PEEK composites can be applied to introduce a new optimum design for femoral prosthesis with adjustable stiffness, which can decrease the stress shielding and interface stress. These findings will help clinicians and biomedical experts to increase their knowledge about the hip replacement.

  6. Assessment of a polyelectrolyte multilayer film coating loaded with BMP-2 on titanium and PEEK implants in the rabbit femoral condyle

    PubMed Central

    Guillot, R.; Pignot-Paintrand, I.; Lavaud, J.; Decambron, A.; Bourgeois, E.; Josserand, V.; Logeart-Avramoglou, D.; Viguier, E.; Picart, C.

    2016-01-01

    The aim of this study was to evaluate the osseointegration of titanium implants (Ti-6Al-4V, noted here TA6V) and poly(etheretherketone) PEEK implants induced by a BMP-2-delivering surface coating made of polyelectrolyte multilayer films. The in vitro bioactivity of the polyelectrolyte film-coated implants was assessed using the alkaline phosphatase assay. BMP-2-coated TA6V and PEEK implants with a total dose of 9.3 µg of BMP-2 were inserted into the femoral condyles of New Zealand white rabbits and compared to uncoated implants. Rabbits were sacrificed 4 and 8 weeks after implantation. Histomorphometric analyses on TA6V and PEEK implants and microcomputed tomography on PEEK implants revealed that the bone-to-implant contact and bone area around the implants were significantly lower for the BMP-2-coated implants than for the bare implants. This was confirmed by scanning electron microscopy imaging. This difference was more pronounced at 4 weeks in comparison to the 8-week time point. However, bone growth inside the hexagonal upper hollow cavity of the screws was higher in the case of the BMP-2 coated implants. Overall, this study shows that a high dose of BMP-2 leads to localized and temporary bone impairment, and that the dose of BMP-2 delivered at the surface of an implant needs to be carefully optimized. PMID:26965394

  7. The incidence of root microcracks caused by 3 different single-file systems versus the ProTaper system.

    PubMed

    Liu, Rui; Hou, Ben Xiang; Wesselink, Paul R; Wu, Min-Kai; Shemesh, Hagay

    2013-08-01

    The aim of this study was to compare the incidence of root cracks observed at the apical root surface and/or in the canal wall after canal instrumentation with 3 single-file systems and the ProTaper system (Dentsply Maillefer, Ballaigues, Switzerland). One hundred mandibular incisors were selected. Twenty control teeth were coronally flared with Gates-Glidden drills (Dentsply Maillefer). No further preparation was made. The other 80 teeth were mounted in resin blocks with simulated periodontal ligaments, and the apex was exposed. They were divided into 4 experimental groups (n = 20); the root canals were first coronally flared with Gates-Glidden drills and then instrumented to the full working length with the ProTaper, OneShape (Micro-Mega, Besancon, France), Reciproc (VDW, Munich, Germany), or the Self-Adjusting File (ReDent-Nova, Ra'anana, Israel). The apical root surface and horizontal sections 2, 4, and 6 mm from the apex were observed under a microscope. The presence of cracks was noted. The chi-square test was performed to compare the appearance of cracked roots between the experimental groups. No cracks were found in the control teeth and teeth instrumented with the Self-Adjusting File. Cracks were found in 10 of 20 (50%), 7 of 20 (35%), and 1 of 20 (5%) teeth after canal instrumentation with the ProTaper, OneShape, and Reciproc files, respectively. The difference between the experimental groups was statistically significant (P < .001). Nickel-titanium instruments may cause cracks on the apical root surface or in the canal wall; the Self-Adjusting File and Reciproc files caused less cracks than the ProTaper and OneShape files. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  8. Supercontinuum generation in an imaging fiber taper

    NASA Astrophysics Data System (ADS)

    Shi, Kebin; Omenetto, Fiorenzo G.; Liu, Zhiwen

    2006-12-01

    We report on supercontinuum generation in individual fibers of a commercial Schott imaging fiber taper. Supercontinuum spectrum covering a wavelength range from about 500 nm to 1 μm was obtained. Unlike conventional approaches which use either a single micro-structured photonic crystal fiber (PCF) or an individual fiber or PCF taper, the availability of many fibers in an imaging taper can open new possibilities to independently and controllably generate supercontinuum arrays.

  9. Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography.

    PubMed

    Mamede-Neto, Iussif; Borges, Alvaro Henrique; Guedes, Orlando Aguirre; de Oliveira, Durvalino; Pedro, Fábio Luis Miranda; Estrela, Carlos

    2017-01-01

    The aim of this study was to evaluate, using cone-beam computed tomography (CBCT), transportation and centralization of different nickel-titanium (NiTi) rotary instruments. One hundred and twenty eight mandibular premolars were selected and instrumented using the following brands of NiTi files: WaveOne, WaveOne Gold, Reciproc, ProTaper Next, ProTaper Gold, Mtwo, BioRaCe and RaCe. CBCT imaging was performed before and after root canal preparation to obtain measurements of mesial and distal dentin walls and calculations of root canal transportation and centralization. A normal distribution of data was confirmed by the Kolmogorov-Smirnov and Levene tests, and results were assessed using the Kruskal-Wallis test. Statistical significance was set at 5%. ProTaper Gold produced the lowest canal transportation values, and RaCe, the highest. ProTaper Gold files also showed the highest values for centering ability, whereas BioRaCe showed the lowest. No significant differences were found across the different instruments in terms of canal transportation and centering ability (P > 0.05). Based on the methodology employed, all instruments used for root canal preparation of mandibular premolars performed similarly with regard to canal transportation and centering ability.

  10. Tapered fiber based high power random laser.

    PubMed

    Zhang, Hanwei; Du, Xueyuan; Zhou, Pu; Wang, Xiaolin; Xu, Xiaojun

    2016-04-18

    We propose a novel high power random fiber laser (RFL) based on tapered fiber. It can overcome the power scaling limitation of RFL while maintaining good beam quality to a certain extent. An output power of 26.5 W has been achieved in a half-open cavity with one kilometer long tapered fiber whose core diameter gradually changes from 8 μm to 20 μm. The steady-state light propagation equations have been modified by taking into account the effective core area to demonstrate the tapered RFL through numerical calculations. The numerical model effectively describes the power characteristics of the tapered fiber based RFL, and both the calculating and experimental results show higher power exporting potential compared with the conventional single mode RFL.

  11. Influence of pore size of porous titanium fabricated by vacuum diffusion bonding of titanium meshes on cell penetration and bone ingrowth.

    PubMed

    Chang, Bei; Song, Wen; Han, Tianxiao; Yan, Jun; Li, Fuping; Zhao, Lingzhou; Kou, Hongchao; Zhang, Yumei

    2016-03-01

    The present work assesses the potential of three-dimensional (3D) porous titanium (pore size of 188-390 μm and porosity of 70%) fabricated by vacuum diffusion bonding of titanium meshes for applications in bone engineering. Rat bone marrow mesenchymal stem cells were used to investigate the proliferation and differentiation of cells on titanium scaffolds with different pore sizes at day 7, day 14 and day 21 based on DNA contents, alkaline phosphatase (ALP) activity, collagen (COL) secretion and osteogenic gene expressions including ALP, COL-1, bone morphogenetic protein-2 (BMP-2), osteopontin (OPN), runt-related transcription factor 2 (RUNX2), using smooth solid titanium plate as reference material. The rabbit models with distal femoral condyles defect were used to investigate the bone ingrowth into the porous titanium. All samples were subjected to Micro-CT and histological analysis after 4 and 12 weeks of healing. A one-way ANOVA followed by Tukey post hoc tests was used to analyze the data. It was found that the differentiation stage of cells on the porous titanium delayed compared with the smooth solid titanium plate and Ti 188 was more inclined to promote cell differentiation at the initial stage (day 14) while cell proliferation (day 1, 4, 7, 10, 14 and 21) and bone ingrowth (4 and 12 weeks) were biased to Ti 313 and Ti 390. The study indicates that the hybrid porous implant design which combines the advantages of different pore sizes may be meaningful and promising for bone defect restoration. One of the significant challenges in bone defect restoration is the integration of biomaterials and surrounding bone tissue. Porous titanium may be a promising choice for bone ingrowth and mineralization with appropriate mechanical and biological properties. In this study, based on porous titanium fabricated by vacuum diffusion bonding of titanium meshes, we have evaluated the influence of various pore sizes on rat bone marrow mesenchymal stem cells (r

  12. IN VIVO SEVERE CORROSION AND HYDROGEN EMBRITTLEMENT OF RETRIEVED MODULAR BODY TITANIUM ALLOY HIP-IMPLANTS

    PubMed Central

    Rodrigues, Danieli C.; Urban, Robert M.; Jacobs, Joshua J.; Gilbert, Jeremy L.

    2009-01-01

    Titanium alloys are widely used in total-joint replacements due to a combination of outstanding mechanical properties, biocompatibility, passivity and corrosion resistance. Nevertheless, retrieval studies have pointed out that these materials can be subjected to localized or general corrosion in modular interfaces when mechanical abrasion of the oxide film (fretting) occurs. Modularity adds large crevice environments, which are subject to micromotion between contacting interfaces and differential aeration of the surface. Titanium alloys are also known to be susceptible to hydrogen absorption, which can induce precipitation of hydrides and subsequent brittle failure. In this work, the surface of three designs of retrieved hip-implants with Ti-6Al-4V/Ti-6Al-4V modular taper interfaces in the stem were investigated for evidence of severe corrosion and precipitation of brittle hydrides during fretting-crevice corrosion in the modular connections. The devices were retrieved from patients and studied by means of scanning electron microscopy (SEM), x-ray diffraction (XRD) and chemical analysis. The surface qualitative investigation revealed severe corrosion attack in the mating interfaces with evidence of etching, pitting, delamination and surface cracking. In vivo hydrogen embrittlement was shown to be a mechanism of degradation in modular connections resulting from electrochemical reactions induced in the crevice environment of the tapers during fretting-crevice corrosion. PMID:18683224

  13. Histomorphometric and histologic evaluation of titanium-zirconium (aTiZr) implants with anodized surfaces.

    PubMed

    Sharma, Ajay; McQuillan, A James; Shibata, Yo; Sharma, Lavanya A; Waddell, John Neil; Duncan, Warwick John

    2016-05-01

    The choice of implant surface has a significant influence on osseointegration. Modification of TiZr surface by anodization is reported to have the potential to modulate the osteoblast cell behaviour favouring more rapid bone formation. The aim of this study is to investigate the effect of anodizing the surface of TiZr discs with respect to osseointegration after four weeks implantation in sheep femurs. Titanium (Ti) and TiZr discs were anodized in an electrolyte containing DL-α-glycerophosphate and calcium acetate at 300 V. The surface characteristics were analyzed by scanning electron microscopy, electron dispersive spectroscopy, atomic force microscopy and goniometry. Forty implant discs with thickness of 1.5 and 10 mm diameter (10 of each-titanium, titanium-zirconium, anodized titanium and anodized titanium-zirconium) were placed in the femoral condyles of 10 sheep. Histomorphometric and histologic analysis were performed 4 weeks after implantation. The anodized implants displayed hydrophilic, porous, nano-to-micrometer scale roughened surfaces. Energy dispersive spectroscopy analysis revealed calcium and phosphorous incorporation into the surface of both titanium and titanium-zirconium after anodization. Histologically there was new bone apposition on all implanted discs, slightly more pronounced on anodised discs. The percentage bone-to-implant contact measurements of anodized implants were higher than machined/unmodified implants but there was no significant difference between the two groups with anodized surfaces (P > 0.05, n = 10). The present histomorphometric and histological findings confirm that surface modification of titanium-zirconium by anodization is similar to anodised titanium enhances early osseointegration compared to machined implant surfaces.

  14. Multidimensional Analysis of Curved Root Canal Preparation Using Continuous or Reciprocating Nickel-titanium Instruments

    PubMed Central

    Mamede-Neto, Iussif; Borges, Álvaro Henrique; Alencar, Ana Helena Gonçalves; Duarte, Marco Antonio Hungaro; Sousa Neto, Manoel Damião; Estrela, Carlos

    2018-01-01

    Objective: To evaluate transportation (T) and centering ability (CA) of root canal preparations using continuous or reciprocating nickel-titanium endodontic files. Materials and Methods: Ninety-six mesiobuccal root canals of mandibular first and second molars were randomly divided into 6 groups (n=16) according to the rotary file used: 1. ProTaper Next; 2. ProTaper Gold; 3. Mtwo; 4. BioRaCe; 5. WaveOne Gold; 6. Reciproc. Root canals were prepared according to manufacturer’s instructions. Cone beam computed tomography scans were obtained before and after root canal preparation. Measurements were made at six different reference points: 2, 3 and 4 mm from the apex and 2, 3 and 4 mm below furcation in different directions. Results: The greatest Mesiodistal (MD) Transportation (T) was found for Reciproc files (p<0.05), and the greatest buccolingual (BL) T, for Reciproc, ProTaper Gold and ProTaper Next files (p<0.05). The greatest Mesiodistal (MD) Centering Ability (CA) was found for BioRaCe files (p<0.05), and the greatest Buccolingual (BL) CA, for BioRaCe and Mtwo files (p<0.05). Conclusion: All systems produced root canal transportation. No file system achieved perfect CA of root preparation. Reciproc files had the greatest MD T and BL T. BioRaCe files had the greatest MD CA, whereas BL CA was similar for BioRaCe and Mtwo files. PMID:29456772

  15. Fabrication of longitudinally arbitrary shaped fiber tapers

    NASA Astrophysics Data System (ADS)

    Nold, J.; Plötner, M.; Böhme, S.; Sattler, B.; deVries, O.; Schreiber, T.; Eberhardt, R.; Tünnermann, A.

    2018-02-01

    We present our current results on the fabrication of arbitrary shaped fiber tapers on our tapering rig using a CO2-laser as heat source. Single mode excitation of multimode fibers as well as changing the fiber geometry in an LPG-like fashion is presented. It is shown that this setup allows for reproducible fabrication of single-mode excitation tapers to extract the fundamental mode (M2 < 1.1) from a 30 μm core having an NA of 0.09.

  16. Prophylactic titanium elastic nailing (TEN) following femoral lengthening (Lengthening then rodding) with one or two nails reduces the risk for secondary interventions after regenerate fractures: a cohort study in monolateral vs. bilateral lengthening procedures

    PubMed Central

    2013-01-01

    Background Femoral fracture rates of up to 30% have been reported following lengthening procedures using fixators. “Lengthening then rodding” uses one or two titanium elastic nails (TENs) for prophylactic intramedullary nailing to reduce this complication. The aim of the study was to decide if usage of only one TEN is safe or has it a higher risk of getting a fracture? And we asked if there is a difference between patients with monolateral or bilateral lengthening procedures according to their fracture rate? Methods One or two TENs were implanted in two groups of patients (monolateral and bilateral) after femoral lengthening procedures. The regenerate quality was classified using the Li system and fractures were categorized using the Simpson and Kenwright classification. The follow-up period was at least 1 year after removal of the frame. Results Sixty-seven patients with 101 femoral lengthening procedures were included in 2007–2011. Group A included 34 patients with bilateral lengthening due to congenital short stature. Group B consisted of 33 patients with congenital disorders with leg length discrepancies. Seven fractures in six patients were seen in group A and five fractures in group B. One patient had residual shortening of 1 cm, and 11 fractures healed without relevant deviation (< 5°) or shortening (< 5 mm). A soft-tissue infection in one patient led to early removal of one TEN. Conclusions Fractures occurred in both groups of patients in total in 12 of the 101 cases (12%). The rate of secondary interventions was markedly reduced. Usage of one or two TENs did not influence the fracture rate. PMID:24156728

  17. Effect of autoclaving on the surfaces of TiN -coated and conventional nickel-titanium rotary instruments.

    PubMed

    Spagnuolo, G; Ametrano, G; D'Antò, V; Rengo, C; Simeone, M; Riccitiello, F; Amato, M

    2012-12-01

    To evaluate the effects of repeated autoclave sterilization cycles on surface topography of conventional nickel-titanium ( NiTi ) and titanium nitride ( TiN )-coated rotary instruments. A total of 60 NiTi rotary instruments, 30 ProTaper (Dentsply Maillefer) and 30 TiN -coated AlphaKite (Komet/Gebr. Brasseler), were analysed. Instruments were evaluated in the as-received condition and after 1, 5 and 10 sterilization cycles. After sterilization, the samples were observed using scanning electron microscope (SEM), and surface chemical analysis was performed on each instrument with energy dispersive X-ray spectroscopy (EDS). Moreover, the samples were analysed by atomic force microscopy (AFM), and roughness average (Ra) and the root mean square value (RMS) of the scanned surface profiles were recorded. Data were analysed by means of anova followed by Tukey's test. Scanning electron microscope observations revealed the presence of pitting and deep milling marks in all instruments. EDS analysis confirmed that both types of instruments were composed mainly of nickel and titanium, whilst AlphaKite had additional nitride. After multiple autoclave sterilization cycles, SEM examinations revealed an increase in surface alterations, and EDS values indicated changes in chemical surface composition in all instruments. Ra and RMS values of ProTaper significantly increased after 5 (P = 0.006) and 10 cycles (P = 0.002) with respect to the as-received instruments, whilst AlphaKite showed significant differences compared with the controls after 10 cycles (P = 0.03). Multiple autoclave sterilization cycles modified the surface topography and chemical composition of conventional and TiN -coated NiTi rotary instruments. © 2012 International Endodontic Journal.

  18. Influence of Femoral Component Design on Retrograde Femoral Nail Starting Point.

    PubMed

    Service, Benjamin C; Kang, William; Turnbull, Nathan; Langford, Joshua; Haidukewych, George; Koval, Kenneth J

    2015-10-01

    Our experience with retrograde femoral nailing after periprosthetic distal femur fractures was that femoral components with deep trochlear grooves posteriorly displace the nail entry point resulting in recurvatum deformity. This study evaluated the influence of distal femoral prosthetic design on the starting point. One hundred lateral knee images were examined. The distal edge of Blumensaat's line was used to create a ratio of its location compared with the maximum anteroposterior condylar width called the starting point ratio (SPR). Femoral trials from 6 manufacturers were analyzed to determine the location of simulated nail position in the sagittal plane compared with the maximum anteroposterior prosthetic width. These measurements were used to create a ratio, the femoral component ratio (FCR). The FCR was compared with the SPR to determine if a femoral component would be at risk for retrograde nail starting point posterior to the Blumensaat's line. The mean SPR was 0.392 ± 0.03, and the mean FCR was 0.416 ± 0.05, which was significantly greater (P = 0.003). The mean FCR was 0.444 ± 0.06 for the cruciate retaining (CR) trials and was 0.393 ± 0.04 for the posterior stabilized trials; this difference was significant (P < 0.001). The FCR for the femoral trials studied was significantly greater than the SPR for native knees and was significantly greater for CR femoral components compared with posterior stabilized components. These findings demonstrate that many total knee prostheses, particularly CR designs, are at risk for a starting point posterior to Blumensaat's line.

  19. Electromagnetic field tapering using all-dielectric gradient index materials.

    PubMed

    Yi, Jianjia; Piau, Gérard-Pascal; de Lustrac, André; Burokur, Shah Nawaz

    2016-07-28

    The concept of transformation optics (TO) is applied to control the flow of electromagnetic fields between two sections of different dimensions through a tapering device. The broadband performance of the field taper is numerically and experimentally validated. The taper device presents a graded permittivity profile and is fabricated through three-dimensional (3D) polyjet printing technology using low-cost all-dielectric materials. Calculated and measured near-field mappings are presented in order to validate the proposed taper. A good qualitative agreement is obtained between full-wave simulations and experimental tests. Such all-dielectric taper paves the way to novel types of microwave devices that can be easily fabricated through low-cost additive manufacturing processes.

  20. Pulse compression using a tapered microstructure optical fiber.

    PubMed

    Hu, Jonathan; Marks, Brian S; Menyuk, Curtis R; Kim, Jinchae; Carruthers, Thomas F; Wright, Barbara M; Taunay, Thierry F; Friebele, E J

    2006-05-01

    We calculate the pulse compression in a tapered microstructure optical fiber with four layers of holes. We show that the primary limitation on pulse compression is the loss due to mode leakage. As a fiber's diameter decreases due to the tapering, so does the air-hole diameter, and at a sufficiently small diameter the guided mode loss becomes unacceptably high. For the four-layer geometry we considered, a compression factor of 10 can be achieved by a pulse with an initial FWHM duration of 3 ps in a tapered fiber that is 28 m long. We find that there is little difference in the pulse compression between a linear taper profile and a Gaussian taper profile. More layers of air-holes allows the pitch to decrease considerably before losses become unacceptable, but only a moderate increase in the degree of pulse compression is obtained.

  1. Process for synthesizing titanium carbide, titanium nitride and titanium carbonitride

    DOEpatents

    Koc, Rasit; Glatzmaier, Gregory C.

    1995-01-01

    A process for synthesizing titanium carbide, titanium nitride or titanium carbonitride. The process comprises placing particles of titanium, a titanium salt or titanium dioxide within a vessel and providing a carbon-containing atmosphere within the vessel. The vessel is heated to a pyrolysis temperature sufficient to pyrolyze the carbon to thereby coat the particles with a carbon coating. Thereafter, the carbon-coated particles are heated in an inert atmosphere to produce titanium carbide, or in a nitrogen atmosphere to produce titanium nitride or titanium carbonitride, with the heating being of a temperature and time sufficient to produce a substantially complete solid solution.

  2. Thulium fiber laser lithotripsy using tapered fibers.

    PubMed

    Blackmon, Richard L; Irby, Pierce B; Fried, Nathaniel M

    2010-01-01

    The Thulium fiber laser has recently been tested as a potential alternative to the Holmium:YAG laser for lithotripsy. This study explores use of a short taper for expanding the Thulium fiber laser beam at the distal tip of a small-core fiber. Thulium fiber laser radiation with a wavelength of 1,908 nm, 10 Hz pulse rate, 70 mJ pulse energy, and 1-millisecond pulse duration was delivered through a 2-m-length fiber with 150-microm-core-input-end, 300-microm-core-output-end, and 5-mm-length taper, in contact with human uric acid (UA) and calcium oxalate monohydrate (COM) stones, ex vivo (n = 10 each). Stone mass loss, stone crater depths, fiber transmission losses, fiber burn-back, irrigation rates, and deflection through a flexible ureteroscope were measured for the tapered fiber and compared with conventional fibers. After delivery of 1,800 pulses through the tapered fiber, mass loss measured 12.7+/-2.6 mg for UA and 7.2+/-0.8 mg COM stones, comparable to conventional 100-microm-core fibers (12.6+/-2.5 mg for UA and 6.8+/-1.7 mg for COM stones). No transmission losses or burn-back occurred for the tapered fiber after 36,000 pulses, while a conventional 150-microm fiber experienced significant tip degradation after only 1,800 pulses. High irrigation rates were measured with the tapered fiber inserted through the working port of a flexible ureteroscope without hindering its deflection, mimicking that of a conventional 150 microm fiber. The short tapered distal fiber tip allows expansion of the laser beam, resulting in decreased fiber tip damage compared to conventional small-core fibers, without compromising fiber bending, stone vaporization efficiency, or irrigation rates.

  3. Process for synthesizing titanium carbide, titanium nitride and titanium carbonitride

    DOEpatents

    Koc, R.; Glatzmaier, G.C.

    1995-05-23

    A process is disclosed for synthesizing titanium carbide, titanium nitride or titanium carbonitride. The process comprises placing particles of titanium, a titanium salt or titanium dioxide within a vessel and providing a carbon-containing atmosphere within the vessel. The vessel is heated to a pyrolysis temperature sufficient to pyrolyze the carbon to thereby coat the particles with a carbon coating. Thereafter, the carbon-coated particles are heated in an inert atmosphere to produce titanium carbide, or in a nitrogen atmosphere to produce titanium nitride or titanium carbonitride, with the heating being of a temperature and time sufficient to produce a substantially complete solid solution.

  4. Polymer optical fiber tapering using hot water

    NASA Astrophysics Data System (ADS)

    Mizuno, Yosuke; Ujihara, Hiroki; Lee, Heeyoung; Hayashi, Neisei; Nakamura, Kentaro

    2017-06-01

    We perform a pilot trial of highly convenient taper fabrication for polymer optical fibers (POFs) using hot water. A ∼380-mm-long POF taper is successfully fabricated, and its ∼150-mm-long waist has a uniform outer diameter of ∼230 µm. The shape is in good agreement with the theoretical prediction. The optical loss dependence on the strain applied to the waist shows an interesting behavior exhibiting three regimes, the origins of which are inferred by microscopic observations. We then discuss the controllability of the taper length.

  5. Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments.

    PubMed

    Haïkel, Y; Serfaty, R; Bateman, G; Senger, B; Allemann, C

    1999-06-01

    The absence of adequate testing standards for engine-driven nickel-titanium (NiTi) instruments necessitates further study of these instruments in all areas. This study examined three groups of engine-driven rotary NiTi endodontic instruments (Profile, Hero, and Quantec) and assessed the times for dynamic fracture in relation to the radius of curvature to which the instruments were subjected during preparation, with the instrument diameter determined by size and taper and the mode by which the fracture occurred. Ten instruments were randomly selected representing each size and taper for each group and for each radius of curvature: 600 in total. The instruments were rotated at 350 rpm and introduced into a tempered steel curve that simulated a canal. Two radii of curvature of canals were used: 5 and 10 mm. Time at fracture was noted for all files, and the fracture faces of each file were analyzed with scanning electron microscopy. Radius of curvature was found to be the most significant factor in determining the fatigue resistance of the files. As radius of curvature decreased, fracture time decreased. Taper of files was found to be significant in determining fracture time. As diameter increased, fracture time decreased. In all cases, fracture was found to be of a ductile nature, thus implicating cyclic fatigue as a major cause of failure and necessitating further analyses and setting of standards in this area.

  6. Femoral nerve damage (image)

    MedlinePlus

    The femoral nerve is located in the leg and supplies the muscles that assist help straighten the leg. It supplies sensation ... leg. One risk of damage to the femoral nerve is pelvic fracture. Symptoms of femoral nerve damage ...

  7. Comparison of the cyclic fatigue resistance of 5 different rotary pathfinding instruments made of conventional nickel-titanium wire, M-wire, and controlled memory wire.

    PubMed

    Capar, Ismail Davut; Kaval, Mehmet Emin; Ertas, Hüseyin; Sen, Bilge Hakan

    2015-04-01

    This study compared the cyclic fatigue resistance of current nickel-titanium rotary path-finding instruments. Five types of nickel-titanium rotary pathfinding instruments were used in steel canals with a 90° curvature and a curvature radius of 3 mm (n = 10) and 5 mm (n = 10). The cyclic fatigue of the following instruments was tested at 4 mm from the tip: PathFile (#16 and a .02 taper; Dentsply Maillefer, Ballaigues, Switzerland), G-File (#12 and a .03 taper; Micro-Mega, Besançon Cedex, France), Scout Race (#15 and a .02 taper; FKG Dentaire, La Chaux-de-Fonds, Switzerland), HyFlex GPF (#15 and a .02 taper; Coltene-Whaledent, Allstetten, Switzerland), and ProGlider (#16 with a mean taper of .04125 and a .02 at the first 4 mm from the tip, Dentsply Maillefer). The length of the fractured parts was measured, and the number of cycles to fracture (NCF) was calculated. The data were statistically analyzed using Kruskal-Wallis and Mann-Whitney tests (α = .05). After Bonferroni correction, the new P value was set as .005. The difference in the cyclic fatigue of all the files at both curvatures was statistically significant (P values from .0035 to less than .0001). The ranking of the instruments from the highest to the lowest NCF was as follows: HyFlex GPF, G files, ProGlider, PathFile, and Scout Race. The length of the fractured part of the instruments was similar in all the groups (P > .05). All the tested instruments had a lower NCF at a curvature radius of 3 mm when compared with a curvature radius of 5 mm (P < .0001). Within the limitations of this study, the cyclic fatigue resistance of the HyFlex GPF instrument was the highest, and the curvature radius had a significant effect on the fatigue resistance. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  8. Multiple-taper spectral analysis: A stand-alone C-subroutine

    NASA Astrophysics Data System (ADS)

    Lees, Jonathan M.; Park, Jeffrey

    1995-03-01

    A simple set of subroutines in ANSI-C are presented for multiple taper spectrum estimation. The multitaper approach provides an optimal spectrum estimate by minimizing spectral leakage while reducing the variance of the estimate by averaging orthogonal eigenspectrum estimates. The orthogonal tapers are Slepian nπ prolate functions used as tapers on the windowed time series. Because the taper functions are orthogonal, combining them to achieve an average spectrum does not introduce spurious correlations as standard smoothed single-taper estimates do. Furthermore, estimates of the degrees of freedom and F-test values at each frequency provide diagnostics for determining levels of confidence in narrow band (single frequency) periodicities. The program provided is portable and has been tested on both Unix and Macintosh systems.

  9. Comparative evaluation of the shaping ability of two different nickel-titanium rotary files in curved root canals of extracted human molar teeth.

    PubMed

    Ferrara, Giulia; Taschieri, Silvio; Corbella, Stefano; Ceci, Caterina; Del Fabbro, Massimo; Machtou, Pierre

    2017-02-01

    The aim of the present study was to compare the shaping ability of two different nickel-titanium rotary files in the curved root canals of extracted human molar teeth. Thirty root canals of 17 extracted human molars teeth were randomly assigned to two experimental groups (n = 15): ProTaper Next and ProTaper Universal (PTU), on the basis of the rotary files system used. The final size of all apical foramina was 0.25 mm in diameter. Standardized digital radiographs were taken before and after instrumentation in both clinical and proximal views, with a size 10 K-file inserted into the canal for the determination of the angle of curvature and apical transportation. Preparation time and fractured or deformed instruments were also recorded. The unpaired Student's t-test was used to compare results. There was no significant difference between the two instruments with respect to canal straightening and apical transportation before and after instrumentation (P > 0.05). The use of both instruments resulted in a significant reduction in the angle of curvature after instrumentation (P < 0.05). Instrumentation time was significantly greater for PTU (P < 0.05). The ProTaper Universal and ProTaper Next systems performed similarly with regard to the straightening of curved root canals and apical transportation. ProTaper Next was significantly faster than ProTaper Universal. © 2015 Wiley Publishing Asia Pty Ltd.

  10. A Comparison of Apical Bacterial Extrusion in Manual, ProTaper Rotary, and One Shape Rotary Instrumentation Techniques.

    PubMed

    Mittal, Rakesh; Singla, Meenu G; Garg, Ashima; Dhawan, Anu

    2015-12-01

    Apical extrusion of irrigants and debris is an inherent limitation associated with cleaning and shaping of root canals and has been studied extensively because of its clinical relevance as a cause of flare-ups. Many factors affect the amount of extruded intracanal materials. The purpose of this study was to assess the bacterial extrusion by using manual, multiple-file continuous rotary system (ProTaper) and single-file continuous rotary system (One Shape). Forty-two human mandibular premolars were inoculated with Enterococcus faecalis by using a bacterial extrusion model. The teeth were divided into 3 experimental groups (n = 12) and 1 control group (n = 6). The root canals of experimental groups were instrumented according to the manufacturers' instructions by using manual technique, ProTaper rotary system, or One Shape rotary system. Sterilized saline was used as an irrigant, and bacterial extrusion was quantified as colony-forming units/milliliter. The results obtained were statistically analyzed by using one-way analysis of variance for intergroup comparison and post hoc Tukey test for pair-wise comparison. The level for accepting statistical significance was set at P < .05. All the instrumentation techniques resulted in bacterial extrusion, with manual step-back technique exhibiting significantly more bacterial extrusion than the engine-driven systems. Of the 2 engine-driven systems, ProTaper rotary extruded significantly more bacteria than One Shape rotary system (P < .05). The engine-driven nickel-titanium systems were associated with less apical extrusion. The instrument design may play a role in amount of extrusion. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  11. Experimental Investigation of Superradiance in a Tapered Free-Electron Laser Amplifier

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hidaka, Y.; She, Y.; Murphy, J.B.

    2011-03-28

    We report experimental studies of the effect of undulator tapering on superradiance in a single-pass high-gain free-electron laser (FEL) amplifier. The experiments were performed at the Source Development Laboratory (SDL) of National Synchrotron Light Source (NSLS). Efficiency was nearly tripled with tapering. Both the temporal and spectral properties of the superradiant FEL along the uniform and tapered undulator were experimentally characterized using frequency-resolved optical gating (FROG) images. Numerical studies predicted pulse broadening and spectral cleaning by undulator tapering Pulse broadening was experimentally verified. However, spectral cleanliness degraded with tapering. We have performed first experiments with a tapered undulator and amore » short seed laser pulse. Pulse broadening with tapering expected from simulations was experimentally confirmed. However, the experimentally obtained spectra degraded with tapering, whereas the simulations predicted improvement. A further numerical study is under way to resolve this issue.« less

  12. Fiber up-tapering and down-tapering for low-loss coupling between anti-resonant hollow-core fiber and solid-core fiber

    NASA Astrophysics Data System (ADS)

    Zhang, Naiqian; Wang, Zefeng; Xi, Xiaoming

    2017-10-01

    In this paper, we demonstrate a novel method for the low-loss coupling between solid-core multi-mode fibers (MMFs) and anti-resonant hollow-core fibers (AR-HCFs). The core/cladding diameter of the MMF is 50/125μm and the mode field diameter of the AR-HCFs are 33.3μm and 71.2μm of the ice-cream type AR-HCFs and the non-node type ARHCFs, respectively. In order to match the mode field diameters of these two specific AR-HCFs, the mode field diameter of the MMFs is increased or decreased by up-tapering or down-tapering the MMFs. Then, according to the principle of coupled fiber mode matching, the optimal diameter of tapered fiber for low-loss coupling is calculated. Based on beam propagation method, the calculated coupling losses without tapering process are 0.31dB and 0.89dB, respectively for a MMF-HCF-MMF structure of the ice-cream type AR-HCFs and the non-node type AR-HCFs. These values can be reduced to 0.096dB and 0.047dB when the outer diameters of the MMF are down-tapered to 116μm and up-tapered to 269μm, respectively. What's more, these results can also be verified by existing experiments.

  13. Monitoring techniques for the manufacture of tapered optical fibers.

    PubMed

    Mullaney, Kevin; Correia, Ricardo; Staines, Stephen E; James, Stephen W; Tatam, Ralph P

    2015-10-01

    The use of a range of optical techniques to monitor the process of fabricating optical fiber tapers is investigated. Thermal imaging was used to optimize the alignment of the optical system; the transmission spectrum of the fiber was monitored to confirm that the tapers had the required optical properties and the strain induced in the fiber during tapering was monitored using in-line optical fiber Bragg gratings. Tapers were fabricated with diameters down to 5 μm and with waist lengths of 20 mm using single-mode SMF-28 fiber.

  14. Coupled tapering/uptapering of Thirring type soliton pair in nonlinear media

    NASA Astrophysics Data System (ADS)

    Prasad, Shraddha; Dutta, Manoj Kumar; Sarkar, Ram Krishna

    2018-03-01

    The paper investigates coupled tapering/uptapering of Thirring type soliton pair, employing Beam Propagation Method. It is seen that, the pair uptapers in presence of losses and tapers in presence of gain. When the first beam has gain and the second one has losses in the nonlinear medium, the second beam induces uptapering in the first beam, while, first beam induces tapering in the second beam. When the medium provides gain/losses to only one of the two beams, the beam undergoes tapering/uptapering and also induces tapering/uptapering to the other loss less beam; however, magnitude of tapering/uptapering are different.

  15. Where science meets practice: Olympic coaches' crafting of the tapering process.

    PubMed

    Ritchie, Darren; Allen, Justine B; Kirkland, Andrew

    2018-05-01

    Although there is research providing physiologically-based guidance for the content of the taper, this study was the first to examine how coaches actually implement the taper. The purpose of this study was to examine the taper planning and implementation processes of successful Olympic coaches leading up to major competitions and how they learned about tapering. Seven track and field coaches participated in semi-structured interviews exploring their tapering processes. To be considered for inclusion, coaches were required to have coached one or more athletes to an Olympic or Paralympic medal. Through a process of axial and open coding interview transcripts were analysed and lower and higher order themes developed describing the coaches' tapering processes. Our findings indicate that the strategies employed to achieve the desired physiological adaptions of the taper were consistent with research (e.g., reduction in volume whilst maintaining intensity and frequency). However, our findings also suggest that tapering is far from a straight forward "textbook" process. The taper was not restricted to physiological outcomes with coaches considering athletes' psychological as well as physical state. Coaches also involved the athlete in the process, adapted the taper to the athlete, continually monitored its progress, and adapted it further as required.

  16. In-situ Tapering of Chalcogenide Fiber for Mid-infrared Supercontinuum Generation

    PubMed Central

    Rudy, Charles W.; Marandi, Alireza; Vodopyanov, Konstantin L.; Byer, Robert L.

    2013-01-01

    Supercontinuum generation (SCG) in a tapered chalcogenide fiber is desirable for broadening mid-infrared (or mid-IR, roughly the 2-20 μm wavelength range) frequency combs1, 2 for applications such as molecular fingerprinting, 3 trace gas detection, 4 laser-driven particle acceleration, 5 and x-ray production via high harmonic generation. 6 Achieving efficient SCG in a tapered optical fiber requires precise control of the group velocity dispersion (GVD) and the temporal properties of the optical pulses at the beginning of the fiber, 7 which depend strongly on the geometry of the taper. 8 Due to variations in the tapering setup and procedure for successive SCG experiments-such as fiber length, tapering environment temperature, or power coupled into the fiber, in-situ spectral monitoring of the SCG is necessary to optimize the output spectrum for a single experiment. In-situ fiber tapering for SCG consists of coupling the pump source through the fiber to be tapered to a spectral measurement device. The fiber is then tapered while the spectral measurement signal is observed in real-time. When the signal reaches its peak, the tapering is stopped. The in-situ tapering procedure allows for generation of a stable, octave-spanning, mid-IR frequency comb from the sub harmonic of a commercially available near-IR frequency comb. 9 This method lowers cost due to the reduction in time and materials required to fabricate an optimal taper with a waist length of only 2 mm. The in-situ tapering technique can be extended to optimizing microstructured optical fiber (MOF) for SCG10 or tuning of the passband of MOFs, 11 optimizing tapered fiber pairs for fused fiber couplers12 and wavelength division multiplexers (WDMs), 13 or modifying dispersion compensation for compression or stretching of optical pulses.14-16 PMID:23748947

  17. Tapered fibers embedded in silica aerogel.

    PubMed

    Xiao, Limin; Grogan, Michael D W; Leon-Saval, Sergio G; Williams, Rhys; England, Richard; Wadsworth, Willam J; Birks, Tim A

    2009-09-15

    We have embedded thin tapered fibers (with diameters down to 1 microm) in silica aerogel with low loss. The aerogel is rigid but behaves refractively like air, protecting the taper without disturbing light propagation along it. This enables a new class of fiber devices exploiting volume evanescent interactions with the aerogel itself or with dopants or gases in the pores.

  18. Functional significance of the taper of vertebrate cone photoreceptors

    PubMed Central

    Hárosi, Ferenc I.

    2012-01-01

    Vertebrate photoreceptors are commonly distinguished based on the shape of their outer segments: those of cones taper, whereas the ones from rods do not. The functional advantages of cone taper, a common occurrence in vertebrate retinas, remain elusive. In this study, we investigate this topic using theoretical analyses aimed at revealing structure–function relationships in photoreceptors. Geometrical optics combined with spectrophotometric and morphological data are used to support the analyses and to test predictions. Three functions are considered for correlations between taper and functionality. The first function proposes that outer segment taper serves to compensate for self-screening of the visual pigment contained within. The second function links outer segment taper to compensation for a signal-to-noise ratio decline along the longitudinal dimension. Both functions are supported by the data: real cones taper more than required for these compensatory roles. The third function relates outer segment taper to the optical properties of the inner compartment whereby the primary determinant is the inner segment’s ability to concentrate light via its ellipsoid. In support of this idea, the rod/cone ratios of primarily diurnal animals are predicted based on a principle of equal light flux gathering between photoreceptors. In addition, ellipsoid concentration factor, a measure of ellipsoid ability to concentrate light onto the outer segment, correlates positively with outer segment taper expressed as a ratio of characteristic lengths, where critical taper is the yardstick. Depending on a light-funneling property and the presence of focusing organelles such as oil droplets, cone outer segments can be reduced in size to various degrees. We conclude that outer segment taper is but one component of a miniaturization process that reduces metabolic costs while improving signal detection. Compromise solutions in the various retinas and retinal regions occur between

  19. Twist-induced tuning in tapered fiber couplers.

    PubMed

    Birks, T A

    1989-10-01

    The power-splitting ratio of fused tapered single-mode fiber couplers can be reversibly tuned by axial twisting without affecting loss. The twist-tuning behavior of a range of different tapered couplers is described. A simple expression for twist-tuning can be derived by representing the effects of twist by a change in the refractive index profile. Good agreement between this expression and experimental results is demonstrated. Repeated tuning over tens of thousands of cycles is found not to degrade coupler performance, and a number of practical applications, including a freely tunable tapered coupler, are described.

  20. Tapered fluorotellurite microstructured fibers for broadband supercontinuum generation.

    PubMed

    Wang, Fang; Wang, Kangkang; Yao, Chuanfei; Jia, Zhixu; Wang, Shunbin; Wu, Changfeng; Qin, Guanshi; Ohishi, Yasutake; Qin, Weiping

    2016-02-01

    Fluorotellurite microstructured fibers (MFs) based on TeO2-BaF2-Y2O3 glasses are fabricated by using a rod-in-tube method. Tapered fluorotellurite MFs with varied transition region lengths are prepared by employing an elongation machine. By using a tapered fluorotellurite MF with a transition region length of ∼3.3  cm as the nonlinear medium and a 1560 nm femtosecond fiber laser as the pump source, broadband supercontinuum generation covering from 470 to 2770 nm is obtained. The effects of the transition region length of the tapered fluorotellurite MF on supercontinuum generation are also investigated. Our results show that tapered fluorotellurite MFs are promising nonlinear media for generating broadband supercontinuum light expanding from visible to mid-infrared spectral region.

  1. Measuring bacterial growth by refractive index tapered fiber optic biosensor.

    PubMed

    Zibaii, Mohammad Ismail; Kazemi, Alireza; Latifi, Hamid; Azar, Mahmoud Karimi; Hosseini, Seyed Masoud; Ghezelaiagh, Mohammad Hossein

    2010-12-02

    A single-mode tapered fiber optic biosensor was utilized for real-time monitoring of the Escherichia coli (E. coli K-12) growth in an aqueous medium. The applied fiber tapers were fabricated using heat-pulling method with waist diameter and length of 6-7μm and 3mm, respectively. The bacteria were immobilized on the tapered surface using Poly-l-Lysine. By providing the proper condition, bacterial population growth on the tapered surface increases the average surface density of the cells and consequently the refractive index (RI) of the tapered region would increase. The adsorption of the cells on the tapered fiber leads to changes in the optical characteristics of the taper. This affects the evanescent field leading to changes in optical throughput. The bacterial growth rate was monitored at room temperature by transmission of a 1558.17nm distributed feedback (DFB) laser through the tapered fiber. At the same condition, after determining the growth rate of E. coli by means of colony counting method, we compared the results with that obtained from the fiber sensor measurements. This novel sensing method, promises new application such as rapid analysis of the presence of bacteria. Copyright © 2010 Elsevier B.V. All rights reserved.

  2. Tapered capillary optics

    DOEpatents

    Hirsch, Gregory

    1998-01-01

    A metal or glass wire is etched with great precision into a very narrowly tapering cone which has the shape of the desired final capillary-optics bore. By controlling the rate of removal of the wire from an etchant bath, a carefully controlled taper is produced. A sensor measures the diameter of the wire as it leaves the surface of the etchant. This signal is used for feedback control of the withdrawal speed. The etched wire undergoes a treatment to produce an extremely low surface-roughness. The etched and smoothed wire is coated with the material of choice for optimizing the reflectivity of the radiation being focused. This could be a vacuum evaporation, sputtering, CVD or aqueous chemical process. The coated wire is either electroplated, built up with electroless plating, or encapsulated in a polymer cylinder such as epoxy to increase the diameter of the wire for easier handling and greater robustness. During this process, the wire is vertically oriented and tensioned to assure that the wire is absolutely straight. The coated and electroformed wire is bonded to a flat, rigid substrate and is then periodically segmented by cutting or etching a series of narrow slits or grooves into the wire. The wire is vertically oriented and tensioned during the bonding process to assure that it is straight. The original wire material is then chemically etched away through the slits or otherwise withdrawn to leave the hollow internal bore of the final tapered-capillary optical element.

  3. Shaping ability of two M-wire and two traditional nickel-titanium instrumentation systems in S-shaped resin canals.

    PubMed

    Ceyhanli, K T; Kamaci, A; Taner, M; Erdilek, N; Celik, D

    2015-01-01

    The aim of this study was to evaluate the shaping effects of two M-wire and two traditional nickel-titanium (NiTi) rotary systems in simulated S-shaped resin canals. Forty simulated S-shaped canals in resin blocks were instrumented with two traditional (ProTaper, Sendoline S5) and two M-wire (WaveOne, GT series X) NiTi systems according to the manufacturers' instructions. Ten resin blocks were used for each system. Pre- and post-instrumentation images were captured using a stereomicroscope and superimposed with an image program. Canal transportation, material removal, and aberrations were evaluated and recorded as numeric parameters. Data were analyzed using one-way ANOVA and post-hoc Tukey tests with a 95% confidence interval. There were significant differences between systems in terms of transportation and material removal (P<0.05). Coronal danger zone was the most common aberration. Within the limits of this ex vivo study, it was found that the manufacturing methods (M-wire or traditional NiTi) and kinematics (rotary or reciprocating motion) did not affect the shaping abilities of the systems. The extended file designs of highly tapered NiTi systems (ProTaper, WaveOne) resulted in greater deviations from the original root canal trace and more material removal when compared to less tapered systems (Sendoline S5, GT series X).

  4. Lateral and axial cutting efficiency of instruments manufactured with conventional nickel-titanium and novel gold metallurgy.

    PubMed

    Vasconcelos, R A; Arias, A; Peters, O A

    2018-05-01

    To isolate the effect of metallurgy in lateral and axial cutting efficacy against plastic and bovine dentine substrates by comparing two rotary systems with identical design but manufactured with either conventional nickel-titanium or heat-treated gold alloy. A total of 258 ProTaper Universal (PTU) and ProTaper Gold (PTG) Shaping instruments were used. Bending behaviour was assessed to determine the appropriate displacement associated with a 2 N force in lateral cutting. Ten instruments of each type were used in lateral action for 60 s against bovine dentine or plastic substrates four consecutive times producing four notches in each specimen. Ten further instruments of each type were used in on axial action in four standardized simulated root canals fabricated from 4-mm thick plastic or dentine discs. Both tests were performed at 300 rpm in a computer-controlled testing platform. Notch area and torsional load were compared with Student's t-tests. Repeated measures ANOVA was used to compare cutting efficiency across the four different time-points. Pearson correlation coefficients between substrates were also determined. For lateral action, all three PTG instruments cut significantly more effectively (P < 0.05) than PTU on the plastic substrate. S1 and S2 PTG cut significantly more after 120 and 180 s (P < 0.05) on bovine dentine substrate. For axial action, S1 and S2 PTG were significantly more efficient in cutting at 180 s on plastic and 120 s on bovine dentine (P < 0.05). Instruments made from heat-treated nickel-titanium gold alloy had equal or greater cutting efficiency when compared to those made from conventional nickel-titanium. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  5. Fatigue delamination onset prediction in tapered composite laminates

    NASA Technical Reports Server (NTRS)

    Murri, Gretchen Bostaph; Salpekar, Satish A.; Obrien, T. Kevin

    1989-01-01

    Tapered (0 deg) laminates of S2/CE9000 and S2/SP250 glass/epoxies, and IM6/1827I graphite/epoxy were tested in cyclic tension. The specimens usually showed some initial stable delaminations in the tapered region, but these did not affect the stiffness of the specimens, and loading was continued until the specimens either delaminated unstably, or reached 10(exp 6) to 2 x 10(exp 7) million cycles with no unstable delamination. The final unstable delamination originated at the junction of the thin and tapered regions. A finite-element model was developed for the tapered laminate with and without the initial stable delaminations observed in the tests. The analysis showed that for both cases the most likely place for an opening (Mode 1) delamination to originate is at the junction of the taper and thin regions. For each material type, the models were used to calculate the strain energy release rate, G, associated with delaminations originating at that junction and growing either into the thin region or tapered region. For the materials tested, cyclic G(sub Imax) values from DCB tests were used with the maximum strain energy release rates calculated from the finite-element analysis to predict the onset of unstable delamination at the junction as a function of fatigue cycles. The predictions were compared to experimental values of maximum cyclic load as a function of cycles to unstable delamination from fatigue tests in tapered laminates. For the IM6/1827I and S2/SP250 laminates, the predictions agreed very well with the test data. Predicted values for the S2/CE9000 were conservative compared to the test data.

  6. Direct current stimulation of titanium interbody fusion devices in primates.

    PubMed

    Cook, Stephen D; Patron, Laura P; Christakis, Petros M; Bailey, Kirk J; Banta, Charles; Glazer, Paul A

    2004-01-01

    The fusion rate for anterior lumbar interbody fusion (ALIF) varies widely with the use of different interbody devices and bone graft options. Adjunctive techniques such as electrical stimulation may improve the rate of bony fusion. To determine if direct current (DC) electrical stimulation of a metallic interbody fusion device enhanced the incidence or extent of anterior bony fusion. ALIF was performed using titanium alloy interbody fusion devices with and without adjunctive DC electrical stimulation in nonhuman primates. ALIF was performed through an anterolateral approach in 35 macaques with autogenous bone graft and either a titanium alloy (Ti-6Al-4V) fusion device or femoral allograft ring. The fusion devices of 19 animals received high (current density 19.6 microA/cm2) or low (current density 5.4 microA/cm2) DC electrical stimulation using an implanted generator for a 12- or 26-week evaluation period. Fusion sites were studied using serial radiographs, computed tomography imaging, nondestructive mechanical testing and qualitative and semiquantitative histology. Fusion was achieved with the titanium fusion device and autogenous bone graft. At 12 weeks, the graft was consolidating and early to moderate bridging callus was observed in and around the device. By 26 weeks, the anterior callus formation was more advanced with increased evidence of bridging trabeculations and early bone remodeling. The callus formation was not as advanced or abundant for the allograft ring group. Histology revealed the spinal fusion device had an 86% incidence of bony fusion at 26 weeks compared with a 50% fusion rate for the allograft rings. DC electrical stimulation of the fusion device had a positive effect on anterior interbody fusion by increasing both the presence and extent of bony fusion in a current density-dependent manner. Adjunctive DC electrical stimulation of the fusion device improved the rate and extent of bony fusion compared with a nonstimulated device. The fusion

  7. Welding-fume-induced transmission loss in tapered optical fibers

    NASA Astrophysics Data System (ADS)

    Yi, Ji-Haeng

    2015-09-01

    This paper presents a method for sensing welding fumes in real time. This method is based on the results of nanoparticle-induced optical-fiber loss experiments that show that the losses are determined by the nanoparticle density and the taper waist. The tapered fiber is obtained by applying heat radiated from hot quartz, and monitoring is done in real time. First, the durability of the tapered fiber during the welding process is proven. Then, the loss is categorized by using the sizes of welding fume particles. The sensitivity to welding fumes increases with increasing size of the particles; consequently, the dimension of the taper waist decreases.

  8. Ultra-low-loss tapered optical fibers with minimal lengths

    NASA Astrophysics Data System (ADS)

    Nagai, Ryutaro; Aoki, Takao

    2014-11-01

    We design and fabricate ultra-low-loss tapered optical fibers (TOFs) with minimal lengths. We first optimize variations of the torch scan length using the flame-brush method for fabricating TOFs with taper angles that satisfy the adiabaticity criteria. We accordingly fabricate TOFs with optimal shapes and compare their transmission to TOFs with a constant taper angle and TOFs with an exponential shape. The highest transmission measured for TOFs with an optimal shape is in excess of 99.7 % with a total TOF length of only 23 mm, whereas TOFs with a constant taper angle of 2 mrad reach 99.6 % transmission for a 63 mm TOF length.

  9. Metallic wear in failed titanium-alloy total hip replacements. A histological and quantitative analysis.

    PubMed

    Agins, H J; Alcock, N W; Bansal, M; Salvati, E A; Wilson, P D; Pellicci, P M; Bullough, P G

    1988-03-01

    We conducted extensive histological examination of the tissues that were adjacent to the prosthesis in nine hips that had a failed total arthroplasty. The prostheses were composed of titanium alloy (Ti-6Al-4V) and ultra-high molecular weight polyethylene. The average time that the prosthesis had been in place in the tissue was 33.5 months (range, eleven to fifty-seven months). Seven arthroplasties were revised because of aseptic loosening and two, for infection. In eight hips cement had been used and in one (that had a porous-coated implant for fifty-two months) no cement had been utilized. Intense histiocytic and plasma-cell reaction was noted in the pseudocapsular tissue. There was copious metallic staining of the lining cells. Polyethylene debris and particles of cement with concomitant giant-cell reaction were present in five hips. Atomic absorption spectrophotometry revealed values for titanium of fifty-sic to 3700 micrograms per gram of dry tissue (average, 1047 micrograms per gram; normal, zero microgram per gram), for aluminum of 2.1 to 396 micrograms per gram (average, 115 micrograms per gram; normal, zero micrograms per gram), and for vanadium of 2.9 to 220 micrograms per gram (average, sixty-seven micrograms per gram; normal, 1.2 micrograms per gram). The highest values were found in the hip in which surgical revision was performed at fifty-seven months. The concentrations of the three elements in the soft tissues were similar to those in the metal of the prostheses. The factors to which failure was attributed were: vertical orientation of the acetabular component (five hips), poor cementing technique on the femoral side (three hips), infection (two hips), and separation of a sintered pad made of pure titanium (one hip). A femoral component that is made of titanium alloy can undergo severe wear of the surface and on the stem, where it is loose, with liberation of potentially toxic local concentrations of metal debris into the surrounding tissues. It may

  10. Comparison of debris extruded apically and working time used by ProTaper Universal rotary and ProTaper retreatment system during gutta-percha removal

    PubMed Central

    UEZU, Mary Kinue Nakamune; BRITTO, Maria Leticia Borges; NABESHIMA, Cleber K.; PALLOTTA, Raul Capp

    2010-01-01

    Objective The aim of this study was to evaluate the in vitro action of ProTaper retreatment files and ProTaper Universal in the retreatment of mandibular premolars. Material and methods The amount of debris extruded apically was measured and the time to reach the working length and to complete the removal of gutta-percha was observed. Thirty teeth had their canals prepared using ProTaper Universal files and were obturated by the single cone technique. The teeth were then stored at 37ºC in a humid environment for 7 days. During the use of the rotary instruments for root canal filling removal, the apical portions of the teeth were attached to the open end of a resin tube to collect the apically extruded debris. Results ProTaper Universal files were significantly faster (p=0.0011) than the ProTaper retreatment files to perform gutta-percha removal, but no significant difference was found between the files regarding the time to reach the working length or the amount of apical extrusion. Conclusions ProTaper Universal rotary had better results for endodontic retreatment, and both techniques promote similar apical extrusion of debris. PMID:21308282

  11. Tapering Practices of Strongman Athletes: Test-Retest Reliability Study

    PubMed Central

    Pritchard, Hayden J; Keogh, Justin WL

    2017-01-01

    Background Little is currently known about the tapering practices of strongman athletes. We have developed an Internet-based comprehensive self-report questionnaire examining the training and tapering practices of strongman athletes. Objective The objective of this study was to document the test-retest reliability of questions associated with the Internet-based comprehensive self-report questionnaire on the tapering practices of strongman athletes. The information will provide insight on the reliability and usefulness of the online questionnaire for use with strongman athletes. Methods Invitations to complete an Internet questionnaire were sent via Facebook Messenger to identified strongman athletes. The survey consisted of four main areas of inquiry, including demographics and background information, training practices, tapering, and tapering practices. Of the 454 athletes that completed the survey over the 8-week period, 130 athletes responded on Facebook Messenger indicating that they intended to complete, or had completed, the survey. These participants were asked if they could complete the online questionnaire a second time for a test-retest reliability analysis. Sixty-four athletes (mean age 33.3 years, standard deviation [SD] 7.7; mean height 178.2 cm, SD 11.0; mean body mass 103.7 kg, SD 24.8) accepted this invitation and completed the survey for the second time after a minimum 7-day period from the date of their first completion. Agreement between athlete responses was measured using intraclass correlation coefficients (ICCs) and kappa statistics. Confidence intervals (at 95%) were reported for all measures and significance was set at P<.05. Results Test-retest reliability for demographic and training practices items were significant (P<.001) and showed excellent (ICC range=.84 to .98) and fair to almost perfect agreement (κ range=.37-.85). Moderate to excellent agreements (ICC range=.56-.84; P<.01) were observed for all tapering practice measures except

  12. Blue treatment enhances cyclic fatigue resistance of vortex nickel-titanium rotary files.

    PubMed

    Plotino, Gianluca; Grande, Nicola M; Cotti, Elisabetta; Testarelli, Luca; Gambarini, Gianluca

    2014-09-01

    The aim of the present study was to evaluate the difference in cyclic fatigue resistance between Vortex Blue (Dentsply Tulsa Dental, Tulsa, OK) and Profile Vortex nickel-titanium (Dentsply Tulsa Dental) rotary instruments. Two groups of nickel-titanium endodontic instruments, ProFile Vortex and Vortex Blue, consisting of identical instruments in tip size and taper (15/.04, 20/.06, 25/.04, 25/.06, 30/.06, 35/.06, and 40/.04) were tested. Ten instruments from each system and size were tested for cyclic fatigue resistance, resulting in a total of 140 new instruments. All instruments were rotated in a simulated root canal with a 60° angle of curvature and a 5-mm radius of curvature of a specific cyclic fatigue testing device until fracture occurred. The number of cycles to failure and the length of the fractured tip were recorded for each instrument in each group. The mean values and standard deviation were calculated, and data were subjected to 1-way analysis of variance and a Bonferroni t test. Significance was set at the 95% confidence level. When comparing the same size of the 2 different instruments, a statistically significant difference (P < .05) was noted between all sizes of Vortex Blue and Profile Vortex instruments except for tip size 15 and .04 taper (P = 1.000). No statistically significant difference (P > .05) was noted among all groups tested in terms of fragment length. Vortex Blue showed a significant increase in cyclic fatigue resistance when compared with the same sizes of ProFile Vortex. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  13. [Influence of different ultrasonic irrigation solutions after root canal preparation with ProTaper by machine on micro-hardness of root canal dentin].

    PubMed

    Guo, Jiang-li; Zhang, Yan; Zhen, Lei

    2015-08-01

    To develope the influence of different ultrasonic irrigations after root canal preparation with nickel titanium ProTaper on micro-hardness of root canal dentin. Sixty of maxillary anterior teeth with single-canal were collected and randomly divided into 6 groups. Group A was control group, group B was prepared to F3 with nickel titanium ProTaper by machine, group C was ultrasonic irrigated with 3% hydrogen peroxide solution for 1 minute after preparation, group D was ultrasonic irrigated with koutai mouthwash for 1 minute after preparation, group E was ultrasonic irrigated with 17% EDTA solution for 1 minute after preparation, group F was ultrasonic irrigated with distilled water for 1 minute after preparation. The roots were then sectioned horizontally into 3 parts, split longitudinally into halves and examined under a micro Vickers hardness test machine. The data was analyzed by one-way ANOVA and t test with SPSS 17.0 software package. The micro-hardness of group A was (52.66 ± 1.64) HV,(52.08 ± 1.53) HV and (51.47 ± 2.53) HV. There was no significant difference in all parts of the root canal in group A (P>0.05). The micro-hardness of the apical third of root canal was lower than that of the cervical and middle of root canal in the other groups (P<0.05). In the cervical and middle third of the root canals, the micro-hardness of group E was (44.65 ± 1.33) HV and(42.55 ± 1.12) HV, and there were statistical significances between group E and the other groups (P<0.05). In the apical third of root canal,the micro-hardness of group E was (37.82 ± 1.60) HV, and group C was (44.14±1.73) HV, both of the comparative differences with other groups were statistically significant (P<0.05). There was no significant difference among group B, group D and group F (P>0.05). Root canal preparation to F3 with nickel titanium ProTaper by machine can make the micro-hardness of the apical third of root canal decrease. Ultrasonic irrigation with 17% EDTA solution for 1 minute can

  14. Free torsional vibrations of tapered cantilever I-beams

    NASA Astrophysics Data System (ADS)

    Rao, C. Kameswara; Mirza, S.

    1988-08-01

    Torsional vibration characteristics of linearly tapered cantilever I-beams have been studied by using the Galerkin finite element method. A third degree polynomial is assumed for the angle of twist. The analysis presented is valid for long beams and includes the effect of warping. The individual as well as combined effects of linear tapers in the width of the flanges and the depth of the web on the torsional vibration of cantilever I-beams are investigated. Numerical results generated for various values of taper ratios are presented in graphical form.

  15. Stubby stems: good things come in small packages.

    PubMed

    Lombardi, Adolph V; Berend, Keith R; Ng, Vincent Y

    2011-09-09

    Standard-length porous-coated tapered femoral stems perform exceedingly well in primary total hip arthroplasty (THA) at long-term follow-up. Nevertheless, there are multiple reasons to strongly consider the relatively new concept of short tapered stems. First, there is already a wide variation in the lengths of "standard" components and the ideal length is unknown. The goal of tapered stems is to load the proximal femur, and shortened stems accomplish this task. Second, while the distal extension may help prevent varus, unlike cemented stems, which are failure-prone with varus alignment, tapered designs are not. Additionally, elimination of the distal extension may reduce potential stress shielding. Third, short stems obviate problems with proximal-distal mismatch, excessive femoral bowing, diaphyseal deformities, and preexisting hardware. Fourth, implantation of smaller components requires less violation of bone and soft tissue, facilitating less invasive surgical approaches and favorable revision settings if necessary. Fifth, in comparison to hip resurfacing and other unconventional short-stem designs, tapered stems are familiar to most orthopedic surgeons and do not incur a steep learning curve. Finally, our early experience with this implant in 1750 THAs since 2006 has been excellent. In a series of >650 THA, compared to standard-length tapered stems, the short stem had equivalent clinical outcome scores, significantly fewer femoral fractures (12/389 [3.1%] vs 1/269 [0.4%]), and only 1 (1/269 [0.4%]) femoral revision (infection) at 2-year follow-up. Short stems represent the logical progression of a proven precedent in standard-length tapered stems. Copyright 2011, SLACK Incorporated.

  16. Diagnosis Taper Corrosion: When Is It the Taper and When Is It Something Else?

    PubMed

    Della Valle, Craig J; Calkins, Tyler E; Jacobs, Joshua J

    2018-03-01

    There has been an increasing use of modularity at the head-neck junction in total hip arthroplasty to more closely mimic the native anatomy, allowing for optimal leg length and stability. Corrosion at this junction in metal-on-polyethylene bearings can lead to an adverse local tissue reaction (ALTR). This increasingly prevalent condition should be considered in the differential diagnosis of hip pain and difficulty ambulating. A recent symposium by the American Academy of Hip and Knee Surgeons described the diagnosis, etiology, management, and prevention of taper corrosion. This article describes the history, physical, plain and advanced imaging findings, laboratory tests, and other diagnoses that should be taken into consideration when diagnosing taper corrosion. The presence of ALTR due to taper corrosion can mimic other diagnoses such as periprosthetic joint infection, instability, or aseptic loosening. Serum metal levels have been found to be the most effective screening tool for identifying corrosion, but other common causes of hip pain and difficulty ambulating should always be ruled out with the use of radiographs and common laboratory techniques before diagnosing ALTR due to corrosion. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Thin-Ribbon Tapered Couplers For Dielectric Waveguides

    NASA Technical Reports Server (NTRS)

    Otoshi, Tom Y.; Shimabukuro, Fred I.; Yeh, Cavour

    1996-01-01

    Thin-ribbon tapered couplers proposed for launching electro-magnetic waves into dielectric waveguides, which include optical fibers. Intended for use with ribbon dielectric waveguides designed for operation at millimeter or submillimeter wavelengths, made of high-relative-permittivity, low-loss materials and thicknesses comparable to or less than free-space design wavelengths. Coupling efficiencies exceeds those of older tapered couplers.

  18. Influence of cross-sectional design and dimension on mechanical behavior of nickel-titanium instruments under torsion and bending: a numerical analysis.

    PubMed

    Zhang, En-Wei; Cheung, Gary S P; Zheng, Yu-Feng

    2010-08-01

    The aim of this study was to examine the influence of the cross-sectional configuration and dimensions (size and taper) on the torsional and bending behavior of nickel-titanium rotary instruments, taking into account the nonlinear mechanical properties of material. Ten cross-sectional configurations, square, triangular, U-type, S-type (large and small), convex-triangle, and 4 proprietary ones (Mani NRT and RT2, Quantec, and Mtwo), were analyzed under torsion or bending by using a 3-dimensional finite element method. The von Mises stresses were correlated with the critical values for various phases of the nickel-titanium material. Different loading conditions led to unequal patterns of stress distribution. Increasing the applied torque or bending angle resulted in a rise in the corresponding stresses in the instrument. Favorable stress distribution without dangerous stress concentration was observed if the material was undergoing superelastic transformation at that applied load. The ultimate strength of the material was not exceeded when the instrument was bent up to a 50-degree curvature. On the other hand, when a torsional moment of greater than 1.0 N*mm was applied, the maximum stresses developed in some designs would exceed the ultimate strength of the material. Little variation in the von Mises stresses was observed for instruments of different nominal sizes and tapers on bending to similar extent. The cross-sectional design has a greater impact than taper or size of the instrument on the stresses developed in the instrument under either torsion or bending. Certain cross-sectional configurations are prone to fracture by excess torsional stresses. Copyright 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Multiple autoclave cycles affect the surface of rotary nickel-titanium files: an atomic force microscopy study.

    PubMed

    Valois, Caroline R A; Silva, Luciano P; Azevedo, Ricardo B

    2008-07-01

    The purpose of this study was to evaluate the surface of rotary nickel-titanium (Ni-Ti) files after multiple autoclave cycles. Two different types of rotary Ni-Ti (Greater Taper and ProFile) were attached to a glass base. After 1, 5, and 10 autoclave cycles the files were positioned in the atomic force microscope. The analyses were performed on 15 different points. The same files were used as control before any autoclave cycle. The following vertical topographic parameters were measured: arithmetic mean roughness, maximum height, and root mean square. The differences were tested by analysis of variance with Tukey test. All topographic parameters were higher for both Greater Taper and ProFile after 10 cycles compared with the control (P < .05). ProFile also showed higher topographic parameters after 5 cycles compared with the control (P < .05). The results indicated that multiple autoclave cycles increase the depth of surface irregularities located on rotary Ni-Ti files.

  20. Rotational flow in tapered slab rocket motors

    NASA Astrophysics Data System (ADS)

    Saad, Tony; Sams, Oliver C.; Majdalani, Joseph

    2006-10-01

    Internal flow modeling is a requisite for obtaining critical parameters in the design and fabrication of modern solid rocket motors. In this work, the analytical formulation of internal flows particular to motors with tapered sidewalls is pursued. The analysis employs the vorticity-streamfunction approach to treat this problem assuming steady, incompressible, inviscid, and nonreactive flow conditions. The resulting solution is rotational following the analyses presented by Culick for a cylindrical motor. In an extension to Culick's work, Clayton has recently managed to incorporate the effect of tapered walls. Here, an approach similar to that of Clayton is applied to a slab motor in which the chamber is modeled as a rectangular channel with tapered sidewalls. The solutions are shown to be reducible, at leading order, to Taylor's inviscid profile in a porous channel. The analysis also captures the generation of vorticity at the surface of the propellant and its transport along the streamlines. It is from the axial pressure gradient that the proper form of the vorticity is ascertained. Regular perturbations are then used to solve the vorticity equation that prescribes the mean flow motion. Subsequently, numerical simulations via a finite volume solver are carried out to gain further confidence in the analytical approximations. In illustrating the effects of the taper on flow conditions, comparisons of total pressure and velocity profiles in tapered and nontapered chambers are entertained. Finally, a comparison with the axisymmetric flow analog is presented.

  1. Turbine airfoil fabricated from tapered extrusions

    DOEpatents

    Marra, John J

    2013-07-16

    An airfoil (30) and fabrication process for turbine blades with cooling channels (26). Tapered tubes (32A-32D) are bonded together in a parallel sequence, forming a leading edge (21), a trailing edge (22), and pressure and suction side walls (23, 24) connected by internal ribs (25). The tapered tubes may be extruded without camber to simplify the extrusion process, then bonded along matching surfaces (34), forming a non-cambered airfoil (28), which may be cambered in a hot forming process and cut (48) to length. The tubes may have tapered walls that are thinner at the blade tip (T1) than at the base (T2), reducing mass. A cap (50) may be attached to the blade tip. A mounting lug (58) may be forged (60) on the airfoil base and then machined, completing the blade for mounting in a turbine rotor disk.

  2. Mediolateral femoral component position in TKA significantly alters patella shift and femoral roll-back.

    PubMed

    Steinbrück, Arnd; Schröder, Christian; Woiczinski, Matthias; Schmidutz, Florian; Müller, Peter E; Jansson, Volkmar; Fottner, Andreas

    2017-11-01

    Increased retropatellar pressure and altered kinematics are associated with anterior knee pain and unsatisfied patients after total knee arthroplasty (TKA). Since malposition of the implant is believed to contribute to postoperative pain, we performed this in vitro study to evaluate the influence of mediolateral femoral component position on retropatellar pressure as well as tibio-femoral and patella kinematics. For the test, a fixed-bearing TKA was implanted in eight fresh frozen cadaver specimens. To determine the impact of mediolateral (ML) position, three variants of femoral components (3-mm medialization, neutral position and 3-mm lateralization) were produced using rapid prototyping replicas. In a knee rig, a loaded squat from 20° to 120° of flexion was applied. Retropatellar pressure distribution was measured with a pressure-sensitive film. Additionally, an ultrasonic-based three-dimensional motion analysis system was used to register patello- and tibio-femoral kinematics. ML translation of the femoral component by 3 mm did not lead to a significant alteration in retropatellar peak pressure (medial 6.5 ± 2.5 MPa vs. lateral 6.0 ± 2.4 MPa). Following the ML translation of the femoral component, the patella was significantly shifted and tilted in the same directions. Varying the ML femoral component position also led to a significant alteration in femoral roll-back. In day-by-day use, ML position should be chosen with care since there is a significant influence on patella shift and femoral roll-back. Retropatellar pressure is not significantly altered, so there is no clear evidence of an impact on anterior knee pain.

  3. Fat embolism: special situations bilateral femoral fractures and pathologic femoral fractures.

    PubMed

    Kontakis, George M; Tossounidis, Theodoros; Weiss, Kurt; Pape, Hans-Christoph; Giannoudis, Peter V

    2006-10-01

    Few data are available in the literature regarding fat embolism in cases of bilateral femoral and pathological femoral fractures. The incidence of bilateral femoral fractures ranges from 2-9.5% of the total number of patients with femoral fractures, and they usually occur in high energy trauma and multi-trauma patients. Although injury severity scores tend to underestimate the severity of these injuries, fat embolism seems to occur in increased frequency ranging from 4.8-7.5%. Intramedullary nailing, which is the preferred surgical treatment, triggers a systemic inflammatory response that poses an additional burden to pulmonary function. In addition, the femur is a common site of metastatic bone disease. The treatment of impending and actual pathological fractures is complicated by increased rates of lung damage due to various factors. Fat embolism during treatment--mainly with intramedullary nails--generally seems to range from 0-10%.

  4. Adiabatic tapered optical fiber fabrication in two step etching

    NASA Astrophysics Data System (ADS)

    Chenari, Z.; Latifi, H.; Ghamari, S.; Hashemi, R. S.; Doroodmand, F.

    2016-01-01

    A two-step etching method using HF acid and Buffered HF is proposed to fabricate adiabatic biconical optical fiber tapers. Due to the fact that the etching rate in second step is almost 3 times slower than the previous droplet etching method, terminating the fabrication process is controllable enough to achieve a desirable fiber diameter. By monitoring transmitted spectrum, final diameter and adiabaticity of tapers are deduced. Tapers with losses about 0.3 dB in air and 4.2 dB in water are produced. The biconical fiber taper fabricated using this method is used to excite whispering gallery modes (WGMs) on a microsphere surface in an aquatic environment. So that they are suitable to be used in applications like WGM biosensors.

  5. Comparative study of ProTaper gold, reciproc, and ProTaper universal for root canal preparation in severely curved root canals

    PubMed Central

    Arslan, Hakan; Yildiz, Ezgi Doganay; Gunduz, Hicran Ates; Sumbullu, Meltem; Bayrakdar, Ibrahim Sevki; Karatas, Ertugrul; Sumbullu, Muhammed Akif

    2017-01-01

    Aim: The aim of this study is to evaluate the root canal transportation, centering ability, and instrumentation times with the ProTaper Gold (Dentsply Tulsa Dental, Tulsa, OK, USA), Reciproc (VDW, Munich, Germany), and ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland) using cone-beam computed tomography (CBCT). Materials and Methods: Thirty mesial root canals of mandibular first molars with curvature angles of 35°–70° and radii of 2–6 mm were included in the study. Root canal instrumentation was performed up to F2 or R25. The instrumentation times were recorded. CBCT scanning was performed both pre- and post-instrumentation. Root canal transportation and the centering ratio were calculated for groups, and the data were analyzed using a one-way ANOVA and least significant difference post hoc tests for the instrumentation time, root canal transportation, and centering ratio at the 95% confidence level (P = 0.05). Results: At 3, 5, and 7 mm levels, there was no significant difference in the root canal transportation and centering ratio among the groups (P > 0.05). There were significant differences between the Reciproc and ProTaper Universal groups in the instrumentation times (P < 0.05). Conclusion: Root canal transportation and the centering ratio with the ProTaper Gold were similar to those obtained with the ProTaper Universal and Reciproc. PMID:29259355

  6. Flexural-torsional vibration of a tapered C-section beam

    NASA Astrophysics Data System (ADS)

    Dennis, Scott T.; Jones, Keith W.

    2017-04-01

    Previous studies have shown that numerical models of tapered thin-walled C-section beams based on a stepped or piecewise prismatic beam approximation are inaccurate regardless of the number of elements assumed in the discretization. Andrade recently addressed this problem by extending Vlasov beam theory to a tapered geometry resulting in new terms that vanish for the uniform beam. (See One-Dimensional Models for the Spatial Behaviour of Tapered Thin-Walled Bars with Open Cross-Sections: Static, Dynamic and Buckling Analyses, PhD Thesis, University of Coimbra, Portugal, 2012, https://estudogeral.sib.uc.pt) In this paper, we model the coupled bending-twisting vibration of a cantilevered tapered thin-walled C-section using a Galerkin approximation of Andrade's beam equations resulting in an 8-degree-of-freedom beam element. Experimental natural frequencies and mode shapes for 3 prismatic and 2 tapered channel beams are compared to model predictions. In addition, comparisons are made to detailed shell finite element models and exact solutions for the uniform beams to confirm the validity of the approach. Comparisons to the incorrect stepped model are also presented.

  7. Catalog of Window Taper Functions for Sidelobe Control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doerry, Armin W.

    Window taper functions of finite apertures are well-known to control undesirable sidelobes, albeit with performance trades. A plethora of various taper functions have been developed over the years to achieve various optimizations. We herein catalog a number of window functions, and com pare principal characteristics.

  8. Torsional resistance of XP-endo Shaper at body temperature compared with several nickel-titanium rotary instruments.

    PubMed

    Elnaghy, A M; Elsaka, S E

    2018-05-01

    To compare the torsional resistance of XP-endo Shaper (XPS; size 30, .01 taper, FKG Dentaire, La Chaux-de-Fonds, Switzerland) instruments at body temperature with TRUShape (TRS; size 30, .06 taper, Dentsply Tulsa Dental Specialties, Tulsa, OK, USA), ProFile Vortex (PV; size 30, .04 taper, Dentsply Tulsa Dental Specialties) and FlexMaster (FM; size 30, .04 taper, VDW GmbH, Munich, Germany) nickel-titanium rotary instruments. A metal block with a square-shaped mould (5 mm × 5 mm × 5 mm) was positioned inside a glass container. Five millimetres of the tip of each instrument was held inside the metal block by filling the mould with a resin composite. The instruments were tested for torsional resistance in saline solution at 37 °C. Data were analysed using one-way analysis of variance (anova) and Tukey post hoc tests. The significance level was set at P < 0.05. FM had the greatest torsional resistance amongst the instruments tested (P < 0.001). There was no significant difference between FM and PV instruments (P = 0.211). The ranking for torsional resistance values was: FM > PV > TRS > XPS. FlexMaster and ProFile Vortex instruments were more resistant to torsional stress compared with TRUShape and XP-endo Shaper instruments. The manufacturing process used to produce XP-endo Shaper instruments did not enhance their resistance to torsional stress as compared with the other instruments. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  9. Titanium

    USGS Publications Warehouse

    Woodruff, Laurel G.; Bedinger, George M.; Piatak, Nadine M.; Schulz, Klaus J.; DeYoung,, John H.; Seal, Robert R.; Bradley, Dwight C.

    2017-12-19

    Titanium is a mineral commodity that is essential to the smooth functioning of modern industrial economies. Most of the titanium produced is refined into titanium dioxide, which has a high refractive index and is thus able to impart a durable white color to paint, paper, plastic, rubber, and wallboard. Because of their high strength-to-weight ratio and corrosion resistance, titanium metal and titanium metal alloys are used in the aerospace industry as well as for welding rod coatings, biological implants, and consumer goods.Ilmenite and rutile are currently the principal titanium-bearing ore minerals, although other minerals, including anatase, perovskite, and titanomagnetite, could have economic importance in the future. Ilmenite is currently being mined from two large magmatic deposits hosted in rocks of Proterozoic-age anorthosite plutonic suites. Most rutile and nearly one-half of the ilmenite produced are from heavy-mineral alluvial, fluvial, and eolian deposits. Titanium-bearing minerals occur in diverse geologic settings, but many of the known deposits are currently subeconomic for titanium because of complications related to the mineralogy or because of the presence of trace contaminants that can compromise the pigment production process.Global production of titanium minerals is currently dominated by Australia, Canada, Norway, and South Africa; additional amounts are produced in Brazil, India, Madagascar, Mozambique, Sierra Leone, and Sri Lanka. The United States accounts for about 4 percent of the total world production of titanium minerals and is heavily dependent on imports of titanium mineral concentrates to meet its domestic needs.Titanium occurs only in silicate or oxide minerals and never in sulfide minerals. Environmental considerations for titanium mining are related to waste rock disposal and the impact of trace constituents on water quality. Because titanium is generally inert in the environment, human health risks from titanium and titanium

  10. In-line optical fiber sensors based on cladded multimode tapered fibers.

    PubMed

    Villatoro, Joel; Monzón-Hernández, David; Luna-Moreno, Donato

    2004-11-10

    The use of uniform-waist cladded multimode tapered optical fibers is demonstrated for evanescent wave spectroscopy and sensors. The tapering is a simple, low-loss process and consists of stretching the fiber while it is being heated with an oscillating flame torch. As examples, a refractive-index sensor and a hydrogen sensor are demonstrated by use of a conventional graded-index multimode optical fiber. Also, absorbance spectra are measured while the tapers are immersed in an absorbing liquid. It is found experimentally that the uniform waist is the part of the taper that contributes most to the sensor sensitivity. The taper waist diameter may also be used to adjust the sensor dynamic range.

  11. Influence of cyclic torsional preloading on cyclic fatigue resistance of nickel - titanium instruments.

    PubMed

    Pedullà, E; Lo Savio, F; Boninelli, S; Plotino, G; Grande, N M; Rapisarda, E; La Rosa, G

    2015-11-01

    To evaluate the effect of different torsional preloads on cyclic fatigue resistance of endodontic rotary instruments constructed from conventional nickel-titanium (NiTi), M-Wire or CM-Wire. Eighty new size 25, 0.06 taper Mtwo instruments (Sweden & Martina), size 25, 0.06 taper HyFlex CM (Coltene/Whaledent, Inc) and X2 ProTaper Next (Dentsply Maillefer) were used. The Torque and distortion angles at failure of new instruments (n = 10) were measured, and 0% (n = 10), 25%, 50% and 75% (n = 20) of the mean ultimate torsional strength as preloading condition were applied according to ISO 3630-1 for each brand. The twenty files tested for every extent of preload were subjected to 20 or 40 torsional cycles (n = 10). After torsional preloading, the number of cycles to failure was evaluated in a simulated canal with 60° angle of curvature and 5 mm of radius of curvature. Data were analysed using two-way analysis of variance. The fracture surface of each fragment was examined with a scanning electron microscope (SEM). Data were analysed by two-way analyses of variance. Preload repetitions did not influence the cyclic fatigue of the three brands; however, the 25%, 50% and 75% torsional preloading significantly reduced the fatigue resistance of all instruments tested (P < 0.01, P < 0.001 and P < 0.0001, respectively) except for the HyFlex CM preloaded with 25% of the maximum torsional strength (P > 0.05). Torsional preloads reduced the cyclic fatigue resistance of conventional and treated (M-wire and CM-wire) NiTi rotary instruments except for size 25, 0.06 taper HyFlex CM instruments with a 25% of torsional preloading. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  12. Correlation of ultrasound appearance, gross anatomy, and histology of the femoral nerve at the femoral triangle.

    PubMed

    Lonchena, Tiffany K; McFadden, Kathryn; Orebaugh, Steven L

    2016-01-01

    Correlation between ultrasound appearance, gross anatomic characteristics, and histologic structure of the femoral nerve (FN) is lacking. Utilizing cadavers, we sought to characterize the anatomy of the FN, and provide a quantitative measure of its branching. We hypothesize that at the femoral crease, the FN exists as a group of nerve branches, rather than a single nerve structure, and secondarily, that this transition into many branches is apparent on ultrasonography. Nineteen preserved cadavers were investigated. Ultrasonography was sufficient to evaluate the femoral nerve in nine specimens; gross dissection was utilized in all 19. Anatomic characteristics were recorded, including distances from the inguinal ligament to femoral crease, first nerve branch, and complete arborization of the nerve. The nerves from nine specimens were excised for histologic analysis. On ultrasound, the nerve became more flattened, widened, and less discrete as it coursed distally. Branching of the nerve was apparent in 12 of 18 images, with mean distance from inguinal ligament of 3.9 (1.0) cm. However, upon dissection, major branching of the femoral nerve occurred at 3.1 (1.0) cm distal to the inguinal ligament, well proximal to the femoral crease. Histologic analysis was consistent with findings at dissection. The femoral nerve arborizes into multiple branches between the inguinal ligament and the femoral crease. Initial branching is often high in the femoral triangle. As hypothesized, the FN exists as a closely associated group of nerve branches at the level of the femoral crease; however, the termination of the nerve into multiple branches is not consistently apparent on ultrasonography.

  13. Refractive index sensors based on the fused tapered special multi-mode fiber

    NASA Astrophysics Data System (ADS)

    Fu, Xing-hu; Xiu, Yan-li; Liu, Qin; Xie, Hai-yang; Yang, Chuan-qing; Zhang, Shun-yang; Fu, Guang-wei; Bi, Wei-hong

    2016-01-01

    In this paper, a novel refractive index (RI) sensor is proposed based on the fused tapered special multi-mode fiber (SMMF). Firstly, a section of SMMF is spliced between two single-mode fibers (SMFs). Then, the SMMF is processed by a fused tapering machine, and a tapered fiber structure is fabricated. Finally, a fused tapered SMMF sensor is obtained for measuring external RI. The RI sensing mechanism of tapered SMMF sensor is analyzed in detail. For different fused tapering lengths, the experimental results show that the RI sensitivity can be up to 444.517 81 nm/RIU in the RI range of 1.334 9—1.347 0. The RI sensitivity is increased with the increase of fused tapering length. Moreover, it has many advantages, including high sensitivity, compact structure, fast response and wide application range. So it can be used to measure the solution concentration in the fields of biochemistry, health care and food processing.

  14. Tensile and creep properties of titanium-vanadium, titanium-molybdenum, and titanium-niobium alloys

    NASA Technical Reports Server (NTRS)

    Gray, H. R.

    1975-01-01

    Tensile and creep properties of experimental beta-titanium alloys were determined. Titanium-vanadium alloys had substantially greater tensile and creep strength than the titanium-niobium and titanium-molybdenum alloys tested. Specific tensile strengths of several titanium-vanadium-aluminum-silicon alloys were equivalent or superior to those of commercial titanium alloys to temperatures of 650 C. The Ti-50V-3Al-1Si alloy had the best balance of tensile strength, creep strength, and metallurgical stability. Its 500 C creep strength was far superior to that of a widely used commercial titanium alloy, Ti-6Al-4V, and almost equivalent to that of newly developed commercial titanium alloys.

  15. Trunnionosis: Does Head Size Affect Fretting and Corrosion in Total Hip Arthroplasty?

    PubMed

    Del Balso, Christopher; Teeter, Matthew G; Tan, Sok Chuen; Howard, James L; Lanting, Brent A

    2016-10-01

    Wear and tribocorrosion at the modular head-neck taper interface may be a cause of failure in metal-on-polyethylene total hip arthroplasty (THA). The present investigation endeavored to elucidate the effect of femoral head diameter on fretting and corrosion in retrieved head-neck tapers. A retrieval analysis of THA prostheses in vivo for a minimum of 1 year was performed. Twenty-three femoral heads of 32-mm diameter were matched with 28-mm heads based on time in vivo and head length (-3 mm to +8 mm). All included implants featured a single taper design from a single manufacturer. Fretting and corrosion damage scoring was performed for each implant under stereomicroscopic visualization. Head diameter was observed to affect fretting (P = .01), with 32-mm femoral heads exhibiting greater total fretting scores than 28-mm heads. Fretting damage was greatest (P = .01) in the central concentric zone of the femoral head bore tapers, regardless of head diameter, length, or stem offset. No significant effect on total corrosion scores was observed for any head or stem variable. Retrieved implant total corrosion scores were positively correlated (ρ = 0.51, P < .001) with implantation time. Increased femoral head diameter in THA may produce greater fretting damage owing to and increased head-neck moment arm. There is no associated increase in corrosion with 28-mm and 32-mm heads of this taper design. The longer a THA prosthesis is implanted, the greater the risk of damage due to corrosion. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Numerical modelling on stimulated Brillouin scattering characterization for Graphene-clad tapered silica fiber

    NASA Astrophysics Data System (ADS)

    Lee, Hui Jing; Abdullah, Fairuz; Ismail, Aiman

    2017-11-01

    This paper presents finite numerical modelling on the cross-sectional region of tapered single mode fiber and graphene-clad tapered fiber. Surface acoustic wave propagation across the tapered surface region on tapered single mode fiber has a high threshold power at 61.87 W which is challenging to overcome by the incident pump wave. Surface acoustic wave propagation of fiber surface however made tapered wave plausible in the optical sensor application. This research introduces graphene as the cladding layer on tapered fiber, acoustic confinement occurs due to the graphene cladding which lowers the threshold power from 61.87 W to 2.17 W.

  17. The fabrication of a tapered fiber connector and its coupling efficiency

    NASA Astrophysics Data System (ADS)

    Qinggui, Hu; Chengzhong, Li

    2017-11-01

    In order to reduce the adverse influence of transversal displacement of the optical fiber connector, we propose the directional tapered communication fiber connector, in which the fiber head is tapered according to the signal transmission direction to improve efficiency. We used a flame-brush technique to produce the tapered fiber successfully. In the next step, two experiments in different environments were performed; one in a static environment and the other in a vibration environment. The first experiment shows that the efficiency of the tapered connector is higher than that of the common connector in the same transversal displacement. The second experiment shows that the efficiency of the tapered connector is higher than that of the common connector in the same frequency and amplitude.

  18. Focal osteolysis at the junctions of a modular stainless-steel femoral intramedullary nail.

    PubMed

    Jones, D M; Marsh, J L; Nepola, J V; Jacobs, J J; Skipor, A K; Urban, R M; Gilbert, J L; Buckwalter, J A

    2001-04-01

    (mean, 1.27 ng/ mL; range, 0.34 to 3.12 ng/mL) were twice as high as those in group 2 (mean, 0.53 ng/mL; range, 0.12 to 1.26 ng/mL). However, this difference did not reach significance with the numbers available. The differences in serum chromium levels between group 1 and the control group with a one-piece nail (mean, 0.26 ng/mL; range, 0.015 to 1.25 ng/mL) (p<0.01) and a control group without an implant (mean, 0.05 ng/mL; range, 0.015 to 0.25 ng/ mL) (p<0.01) were significant. The level of thigh pain recorded on the visual analog scale was also significantly different between group 1 and the control group with a one-piece implant (p = 0.03). Retrieved modular nails had signs of fretting corrosion as well as stainless-steel corrosion products adherent to the junction where the osteolysis occurred. Histologic and spectrographic analysis revealed two types of corrosion products that were consistent with stainless-steel within the peri-implant tissue and were associated with a foreign-body granulomatous response. The presence of corrosion products at the taper junctions suggests that particulate debris was a major factor in the etiology of the radiographic findings of osteolysis, periosteal reaction, and cortical thickening. Serum chromium levels were substantially elevated in the patients with a modular femoral nail, and such levels may serve as a marker of fretting corrosion of these devices.

  19. Comparison of cyclic fatigue resistance of three different rotary nickel-titanium instruments designed for retreatment.

    PubMed

    Inan, Ugur; Aydin, Cumhur

    2012-01-01

    A number of rotary nickel-titanium (NiTi) systems have been developed to provide better, faster, and easier cleaning and shaping of the root canal system, and recently, rotary NiTi systems designed for root canal retreatment have been introduced. Because the main problem with the rotary NiTi files is fracture, the aim of this study was to compare the cyclic fatigue resistance of 3 different rotary NiTi systems designed for root canal retreatment. Total of 60 instruments of 3 different rotary NiTi systems designed for root canal retreatment were used in this study. Twenty R-Endo R3, 20 ProTaper D3, and 20 Mtwo R (Retreatment) 25.05 instruments were tested. Cyclic fatigue testing of instruments was performed by using a device that allowed the instruments to rotate freely inside an artificial canal. Each instrument was rotated until fracture occurred, and the number of cycles to fracture for each instrument was calculated. Representative samples were also evaluated under a scanning electron microscope to confirm the fracture was flexural. Data were analyzed by using 1-way analysis of variance test. R-Endo R3 instruments showed better cyclic fatigue resistance than ProTaper D3 and Mtwo R 25.05 instruments, and the difference was statistically significant (P < .05). There was no significant difference between ProTaper D3 and Mtwo R 25.05 groups. The R-Endo R3 instruments were more resistant to fatigue failure than ProTaper D3 and Mtwo R 25.05. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  20. Combined tension and bending testing of tapered composite laminates

    NASA Astrophysics Data System (ADS)

    O'Brien, T. Kevin; Murri, Gretchen B.; Hagemeier, Rick; Rogers, Charles

    1994-11-01

    A simple beam element used at Bell Helicopter was incorporated in the Computational Mechanics Testbed (COMET) finite element code at the Langley Research Center (LaRC) to analyze the responce of tappered laminates typical of flexbeams in composite rotor hubs. This beam element incorporated the influence of membrane loads on the flexural response of the tapered laminate configurations modeled and tested in a combined axial tension and bending (ATB) hydraulic load frame designed and built at LaRC. The moments generated from the finite element model were used in a tapered laminated plate theory analysis to estimate axial stresses on the surface of the tapered laminates due to combined bending and tension loads. Surfaces strains were calculated and compared to surface strains measured using strain gages mounted along the laminate length. The strain distributions correlated reasonably well with the analysis. The analysis was then used to examine the surface strain distribution in a non-linear tapered laminate where a similarly good correlation was obtained. Results indicate that simple finite element beam models may be used to identify tapered laminate configurations best suited for simulating the response of a composite flexbeam in a full scale rotor hub.

  1. Variational theory of the tapered impedance transformer

    NASA Astrophysics Data System (ADS)

    Erickson, Robert P.

    2018-02-01

    Superconducting amplifiers are key components of modern quantum information circuits. To minimize information loss and reduce oscillations, a tapered impedance transformer of new design is needed at the input/output for compliance with other 50 Ω components. We show that an optimal tapered transformer of length ℓ, joining the amplifier to the input line, can be constructed using a variational principle applied to the linearized Riccati equation describing the voltage reflection coefficient of the taper. For an incident signal of frequency ωo, the variational solution results in an infinite set of equivalent optimal transformers, each with the same form for the reflection coefficient, each able to eliminate input-line reflections. For the special case of optimal lossless transformers, the group velocity vg is shown to be constant, with characteristic impedance dependent on frequency ωc = πvg/ℓ. While these solutions inhibit input-line reflections only for frequency ωo, a subset of optimal lossless transformers with ωo significantly detuned from ωc does exhibit a wide bandpass. Specifically, by choosing ωo → 0 (ωo → ∞), we obtain a subset of optimal low-pass (high-pass) lossless tapers with bandwidth (0, ˜ ωc) [(˜ωc, ∞)]. From the subset of solutions, we derive both the wide-band low-pass and high-pass transformers, and we discuss the extent to which they can be realized given fabrication constraints. In particular, we demonstrate the superior reflection response of our high-pass transformer when compared to other taper designs. Our results have application to amplifiers, transceivers, and other components sensitive to impedance mismatch.

  2. Comparison of dentinal damage induced by different nickel-titanium rotary instruments during canal preparation: An in vitro study.

    PubMed

    Garg, Shiwani; Mahajan, Pardeep; Thaman, Deepa; Monga, Prashant

    2015-01-01

    To compare dentinal damage caused by hand and rotary nickel-titanium instruments using ProTaper, K3 Endo, and Easy RaCe systems after root canal preparation. One hundred and fifty freshly extracted mandibular premolars were randomly divided into five experimental groups of 30 teeth each and biomechanical preparation was done: Group 1 with unprepared teeth; Group 2 were prepared with hand files; Group 3 with ProTaper rotary instruments; Group 4 with K3 rotary; Group 5 with Easy RaCe rotary instruments. Then, roots were cut horizontally at 3, 6, and 9 mm from apex and were viewed under stereomicroscope. The presence of dentinal defects was noted. Groups were analyzed with the Chi-square test. Significant difference was seen between groups. No defects were found in unprepared roots and those prepared with hand files. ProTaper, K3 rotary, and Easy RaCe preparations resulted in dentinal defects in 23.3%, 10%, and 16.7% of teeth, respectively. More defects were shown in coronal and middle sections, and no defect was seen in apical third. The present study revealed that use of rotary instruments could result in an increased chance for dentinal defects as compared to hand instrumentation.

  3. Tapered polysilicon core fibers for nonlinear photonics.

    PubMed

    Suhailin, Fariza H; Shen, Li; Healy, Noel; Xiao, Limin; Jones, Maxwell; Hawkins, Thomas; Ballato, John; Gibson, Ursula J; Peacock, Anna C

    2016-04-01

    We propose and demonstrate a novel approach to obtaining small-core polysilicon waveguides from the silicon fiber platform. The fibers were fabricated via a conventional drawing tower method and, subsequently, tapered down to achieve silicon core diameters of ∼1  μm, the smallest optical cores for this class of fiber to date. Characterization of the material properties have shown that the taper process helps to improve the local crystallinity of the silicon core, resulting in a significant reduction in the material loss. By exploiting the combination of small cores and low losses, these tapered fibers have enabled the first observation of nonlinear transmission within a polycrystalline silicon waveguide of any type. As the fiber drawing method is highly scalable, it opens a route for the development of low-cost and flexible nonlinear silicon photonic systems.

  4. Nonlinear acoustic streaming in straight and tapered tubes

    NASA Astrophysics Data System (ADS)

    Tuttle, Brian C.

    In thermoacoustic and Stirling devices such as the pulse-tube refrigerator, efficiency is diminished by the formation of a second-order mean velocity known as Rayleigh streaming. This flow emerges from the interaction of the working gas with the wall of the tube in a thin boundary layer. Recent studies have suggested that streaming velocity can be decreased in a tube by tapering it slightly. This research investigates that claim through the development of a numerical model of Rayleigh streaming in variously tapered tubes. It is found that the numerical simulation of streaming in a straight tube compares well with theory, and the application of different thermal boundary conditions at the tube wall shows that for pressurized helium, inner streaming vortices which appear near an adiabatic tube wall do not develop near an isothermal wall. An order analysis indicates that the temperature dependence of viscosity and thermal conductivity contributes appreciably to an accurate numerical model of streaming. Comparison of Rayleigh streaming in tapered tubes shows the effects of taper angle on the circulation and velocity of the mean flow.

  5. Simple Expressions for the Design of Linear Tapers in Overmoded Corrugated Waveguides

    DOE PAGES

    Schaub, S. C.; Shapiro, M. A.; Temkin, R. J.

    2015-08-16

    In this paper, simple analytical formulae are presented for the design of linear tapers with very low mode conversion loss in overmoded corrugated waveguides. For tapers from waveguide radius a2 to a1, with a11a 2/λ. Here, λ is the wavelength of radiation. The fractional loss of the HE 11 mode in an optimized taper is 0.0293(a 2-a 1) 4/amore » $$2\\atop{1}$$1a$$2\\atop{2}$$. These formulae are accurate when a2≲2a 1. Slightly more complex formulae, accurate for a 2≤4a 1, are also presented in this paper. The loss in an overmoded corrugated linear taper is less than 1 % when a 2≤2.12a 1 and less than 0.1 % when a 2≤1.53a 1. The present analytic results have been benchmarked against a rigorous mode matching code and have been found to be very accurate. The results for linear tapers are compared with the analogous expressions for parabolic tapers. Finally, parabolic tapers may provide lower loss, but linear tapers with moderate values of a 2/a 1 may be attractive because of their simplicity of fabrication.« less

  6. Reverse distal femoral locking compression plate a salvage option in nonunion of proximal femoral fractures.

    PubMed

    Dumbre Patil, Sampat S; Karkamkar, Sachin S; Patil, Vaishali S Dumbre; Patil, Shailesh S; Ranaware, Abhijeet S

    2016-01-01

    When primary fixation of proximal femoral fractures with implants fails, revision osteosynthesis may be challenging. Tracts of previous implants and remaining insufficient bone stock in the proximal femur pose unique problems for the treatment. Intramedullary implants like proximal femoral nail (PFN) or surface implants like Dynamic Condylar Screw (DCS) are few of the described implants for revision surgery. There is no evidence in the literature to choose one implant over the other. We used the reverse distal femur locking compression plate (LCP) of the contralateral side in such cases undergoing revision surgery. This implant has multiple options of fixation in proximal femur and its curvature along the length matches the anterior bow of the femur. We aimed to evaluate the efficacy of this implant in salvage situations. Twenty patients of failed primary proximal femoral fractures who underwent revision surgery with reverse distal femoral locking plate from February 2009 to November 2012 were included in this retrospective study. There were 18 subtrochanteric fractures and two ipsilateral femoral neck and shaft fractures, which exhibited delayed union or nonunion. The study included 14 males and six females. The mean patient age was 43.6 years (range 22-65 years) and mean followup period was 52.1 months (range 27-72 months). Delayed union was considered when clinical and radiological signs of union failed to progress at the end of four months from initial surgery. All fractures exhibited union without any complications. Union was assessed clinically and radiologically. One case of ipsilateral femoral neck and shaft fracture required bone grafting at the second stage for delayed union of the femoral shaft fracture. Reverse distal femoral LCP of the contralateral side can be used as a salvage option for failed fixation of proximal femoral fractures exhibiting nonunion.

  7. Efficacy of Different Nickel-Titanium Instruments in Removing Gutta-percha during Root Canal Retreatment.

    PubMed

    Özyürek, Taha; Demiryürek, Ebru Özsezer

    2016-04-01

    The aim of this study was to compare the cleanliness of root canal walls after retreatment using ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland), Twisted File Adaptive (TFA; Axis/SybronEndo, Orange, CA), Reciproc (PRC; VDW, Munich, Germany), and ProTaper Universal retreatment (PTR, Dentsply Maillefer) nickel-titanium systems and the time required for gutta-percha and sealer removal. Eighty human maxillary central incisors with single and straight root canals were instrumented up to #40.02 with manual K-files (Dentsply Maillefer) and obturated using the continuous wave of condensation technique. Removal of the gutta-percha and sealer was performed using 1 of the following nickel-titanium systems: PTN, TFA, RPC, or PTR. The teeth were sectioned, and digital images were captured. The photographs were analyzed using AutoCAD software (Autodesk, San Rafael, CA). Also, the total time required for gutta-percha removal was calculated by a chronometer. The total retreatment time was significantly shorter in the PTR group compared with the other groups (P < .05). There was a significant difference between the groups according to the total residual gutta-percha and sealer (P < .05). The PTN and PTR groups left significantly less gutta-percha and sealer remnant than the TFA and RPC groups (P < .05). Within the limitations of this study, the PTN and the PTR groups showed less residual gutta-percha and sealer than the TFA and RPC groups. The time required for gutta-percha and sealer removal was similar for all the groups, except for the PTR group. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  8. Quantitative evaluation of apically extruded debris during root canal instrumentation with ProTaper Universal, ProTaper Next, WaveOne, and self-adjusting file systems

    PubMed Central

    Ozsu, Damla; Karatas, Ertugrul; Arslan, Hakan; Topcu, Meltem C.

    2014-01-01

    Objectives: The aim of this study was to compare the amount of apically extruded debris during preparation with ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Next (Dentsply Maillefer), a reciprocating single-file (WaveOne; VDW GmbH, Munich, Germany), and a self-adjusting file (SAF; ReDent Nova, Ra’anna, Israel). Materials and Methods: Fifty-six intact mandibular premolar teeth were randomly assigned to four groups. The root canals were prepared according to the manufacturers’ instructions using the ProTaper Universal, ProTaper Next, WaveOne, and SAF. Apically extruded debris was collected in preweighted Eppendorf tubes during instrumentation. The net weight of the apically extruded debris was determined by subtracting the preweights and postweights of the tubes. The data were statistically analyzed using the one-way analysis of variance and the least significant difference tests at a significance level of P < 0.05. Results: A measurable amount of debris was apically extruded in all groups, and the amounts of debris extrusion in the groups were statistically significant (P < 0.001). The ProTaper Next and WaveOne groups resulted in less debris extrusion than the ProTaper Universal group (P < 0.05), and the SAF group resulted in the least debris extrusion. Conclusions: Within the limitations of the present study, it can be concluded that all systems extruded debris beyond the apical foramen. PMID:25512732

  9. Micro-Computed Tomography Evaluation of ProTaper Next and BioRace Shaping Outcomes in Maxillary First Molar Curved Canals.

    PubMed

    Pasqualini, Damiano; Alovisi, Mario; Cemenasco, Andrea; Mancini, Lucia; Paolino, Davide Salvatore; Bianchi, Caterina Chiara; Roggia, Andrea; Scotti, Nicola; Berutti, Elio

    2015-10-01

    The aim of this micro-computed tomography study was to describe the shaping properties of ProGlider/ProTaper Next (PG/PTN) and ScoutRace/BioRace (SR/BR) nickel-titanium rotary systems. Thirty maxillary first permanent molars were selected. Mesiobuccal canals were randomly assigned (n = 15) to PG/PTN or SR/BR groups. Irrigation was performed with 5% NaOCl and 10% EDTA. Specimens were scanned (voxel size, 9.1 μm) for matching volumes and surface areas and post-treatment analyses. Root canal centering ability, canal geometry enlargement, and thickness of dentinal wall at inner curvature were assessed at apical level and point of maximum curvature. Results were analyzed with 4 one-way analyses of variance. Canal centering ability was superior in PG/PTN (P = .006 at apical level, P = .025 at point of maximum curvature). PG/PTN demonstrated a more conservative increase of canal areas (P = .027 at apical level, P = .038 at point of maximum curvature). Centrifugal increase in canal diameters did not significantly differ between groups (P = .65 at apical level, P = .61 at point of maximum curvature). Inner dentinal wall thickness was less reduced with PG/PTN compared with SR/BR, with no statistical differences (P = .23 at point of maximum curvature, P = .89 at apical level). PG/PTN shaping taper ranged between 6% and 7%. Neither system produced significant shaping errors in curved canals. PG/PTN system showed better preservation of canal anatomy. PTN offset section did not influence final preparation taper. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  10. Cyclic fatigue resistance of XP-endo Shaper compared with different nickel-titanium alloy instruments.

    PubMed

    Elnaghy, Amr; Elsaka, Shaymaa

    2018-04-01

    The aims of this study were to assess and compare the resistance to cyclic fatigue of XP-endo Shaper (XPS; FKG Dentaire, La Chaux-de-Fonds, Switzerland) instruments with TRUShape (TRS; Dentsply Tulsa Dental Specialties, Tulsa, OK, USA), HyFlex CM (HCM; Coltene, Cuyahoga Falls, OH, USA), Vortex Blue (VB; Dentsply Tulsa Dental Specialties), and iRace (iR; FKG Dentaire) nickel-titanium rotary instruments at body temperature. Size 30, 0.01 taper of XPS, size 30, 0.04 taper of HCM, VB, iR, and size 30, 0.06 taper of TRS instruments were immersed in saline at 37 ± 1 °C during cyclic fatigue testing. The instruments were tested with 60° angle of curvature and a 3-mm radius of curvature. The number of cycles to failure (NCF) was calculated and the length of the fractured segment was measured. Fractographic examination of the fractured surface was performed using a scanning electron microscope. The data were analyzed statistically using Kruskal-Wallis H test and Mann-Whitney U tests. Statistical significance was set at P < 0.05. XPS had a significantly greater NCF compared with the other instruments (P < 0.001). The topographic appearance of the fracture surfaces of tested instruments revealed ductile fracture of cyclic fatigue failure. XPS instruments exhibited greater cyclic fatigue resistance compared with the other tested instruments. XP-endo Shaper instruments could be used more safely in curved canals due to their higher fatigue resistance.

  11. The effects of tapering on strength performance in trained athletes.

    PubMed

    Gibala, M J; MacDougall, J D; Sale, D G

    1994-11-01

    The optimum pre-competition taper procedure for "strength athletes" is not known. We examined voluntary strength and evoked contractile properties of the elbow flexors over a 10 day rest only (ROT) and a 10 day reduced volume taper (RVT) in 8 resistance trained males (23 +/- 2.1 years). Following 3 wks of standardized training of the elbow flexors, subjects were randomly assigned to one of the tapers. Upon completion, they resumed training for 3 wks and completed the other taper. No arm training was performed during the ROT, while high intensity, low volume training was done every second day during the RVT. Maximum isometric (MVC), low (0.52 rad.s-1; LV) and high velocity (3.14 rad.s-1; HV) concentric peak torque, and evoked isometric twitch contractile properties were measured before and after each training phase and every 48 h during each taper. ANOVA comparison of the tapers revealed that MVC increased (p < or = 0.05) over pre-taper values throughout the RVT (measurement days 2, 4, 6, 8 and 10), as did LV at 2, 4, 6, and 8 d. MVC did not change over the ROT but LV was significantly higher on day 2 and lower on days 8 and 10. LV was also greater on days 4, 6, 8 and 10 during the RVT compared to the ROT. The evoked contractile properties remained largely unchanged. The data indicate that resistance-trained athletes can improve low velocity concentric strength for at least 8 days by greatly reducing training volume, but maintaining training intensity.

  12. 5 CFR 353.303 - Restoration rights of TAPER employees.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Restoration rights of TAPER employees... Restoration rights of TAPER employees. An employee serving in the competitive service under a temporary... she left or an equivalent one in the same commuting area. ...

  13. Narrowband spectral filter based on biconical tapered fiber

    NASA Astrophysics Data System (ADS)

    Celaschi, Sergio; Malheiros-Silveira, Gilliard N.

    2018-02-01

    The ease of fabrication and compactness of devices based on tapered optical fibers contribute to its potential using in several applications ranging from telecommunication components to sensing devices. In this work, we proposed, fabricated, and characterized a spectral filter made of biconical taper from a coaxial optical fiber. This filter is defined by adiabatically tapering a depressed-cladding fiber. The adiabatic taper profile obtained during fabrication prevents the interference of other modes than HE11 and HE12 ones, which play the main role for the beating phenomenon and the filter response. The evolution of the fiber shapes during the pulling was modeled by two coupled partial differential equations, which relate the normalized cross-section area, and the axial velocity of the fiber elongation. These equations govern the mass and axial momentum conservation. The numerical results of the filter characteristics are in good accordance with the experimental ones. The filter was packaged in order to let it ready for using in optical communication bands. The characteristics are: free spectral range (FSR) of 6.19 nm, insertion loss bellow 0.5 dB, and isolation > 20 dB at C-band. Its transmission spectrum extends from 1200 to 1600 nm where the optical fiber core supports monomode transmission. Such characteristics may also be interesting to be applied in sensing applications. We show preliminary numerical results assuming a biconic taper embedded into a dielectric media, showing promising results for electro-optic sensing applications.

  14. Multimode Brillouin spectrum in a long tapered birefringent photonic crystal fiber.

    PubMed

    Tchahame, Joël Cabrel; Beugnot, Jean-Charles; Kudlinski, Alexandre; Sylvestre, Thibaut

    2015-09-15

    We investigate the stimulated Brillouin scattering (SBS) in a long tapered birefringent solid-core photonic crystal fiber (PCF) and compare our results with a similar but untapered PCF. It is shown that the taper generates a broadband and multipeaked Brillouin spectrum, while significantly increasing the threshold power. Furthermore, we observe that the strong fiber birefringence gives rise to a frequency shift of the Brillouin spectrum which increases along the fiber. Numerical simulations are also presented to account for the taper effect and the birefringence. Our findings open a new means to control or inhibit the SBS by tapering photonic crystal fibers.

  15. Correlation Between Residual Displacement and Osteonecrosis of the Femoral Head Following Cannulated Screw Fixation of Femoral Neck Fractures.

    PubMed

    Wang, Chen; Xu, Gui-Jun; Han, Zhe; Jiang, Xuan; Zhang, Cheng-Bao; Dong, Qiang; Ma, Jian-Xiong; Ma, Xin-Long

    2015-11-01

    The aim of the study was to introduce a new method for measuring the residual displacement of the femoral head after internal fixation and explore the relationship between residual displacement and osteonecrosis with femoral head, and to evaluate the risk factors associated with osteonecrosis of the femoral head in patients with femoral neck fractures treated by closed reduction and percutaneous cannulated screw fixation.One hundred and fifty patients who sustained intracapsular femoral neck fractures between January 2011 and April 2013 were enrolled in the study. All were treated with closed reduction and percutaneous cannulated screw internal fixation. The residual displacement of the femoral head after surgery was measured by 3-dimensional reconstruction that evaluated the quality of the reduction. Other data that might affect prognosis were also obtained from outpatient follow-up, telephone calls, or case reviews. Multivariate logistic regression analysis was applied to assess the intrinsic relationship between the risk factors and the osteonecrosis of the femoral head.Osteonecrosis of the femoral head occurred in 27 patients (18%). Significant differences were observed regarding the residual displacement of the femoral head and the preoperative Garden classification. Moreover, we found more or less residual displacement of femoral head in all patients with high quality of reduction based on x-ray by the new technique. There was a close relationship between residual displacement and ONFH.There exists limitation to evaluate the quality of reduction by x-ray. Three-dimensional reconstruction and digital measurement, as a new method, is a more accurate method to assess the quality of reduction. Residual displacement of the femoral head and the preoperative Garden classification were risk factors for osteonecrosis of the femoral head. High-quality reduction was necessary to avoid complications.

  16. Acoustic vibration sensor based on nonadiabatic tapered fibers.

    PubMed

    Xu, Ben; Li, Yi; Sun, Miao; Zhang, Zhen-Wei; Dong, Xin-Yong; Zhang, Zai-Xuan; Jin, Shang-Zhong

    2012-11-15

    A simple and low-cost vibration sensor based on single-mode nonadiabatic fiber tapers is proposed and demonstrated. The environmental vibrations can be detected by demodulating the transmission loss of the nonadiabatic fiber taper. Theoretical simulations show that the transmission loss is related to the microbending of the fiber taper induced by vibrations. Unlike interferometric sensors, this vibration sensor does not need any feedback loop to control the quadrature point to obtain a stable performance. In addition, it has no requirement for the coherence of the light source and is insensitive to temperature changes. Experimental results show that this sensing system has a wide frequency response range from a few hertz to tens of kilohertz with the maximal signal to noise ratio up to 73 dB.

  17. Analysis of initial fixation strength of press-fit fixation technique in anterior cruciate ligament reconstruction. A comparative study with titanium and bioabsorbable interference screw using porcine lower limb.

    PubMed

    Lee, Myung Chul; Jo, Hyunchul; Bae, Tae-Soo; Jang, Jin Dae; Seong, Sang Cheol

    2003-03-01

    We performed a controlled laboratory study to evaluate the initial fixation strength of press-fit technique. Forty porcine lower limbs were used and divided into four groups according to the method of fixation; group 1 (press-fit+1.4 mm), in which the diameter difference between the bone plug and the femoral tunnel was 1.4 mm; group 2 (press-fit+1.4 mm, 30 degrees), in which the diameter difference was the same with group 1, but the tensile loading axis was 30 degrees away from the long axis of the femoral tunnel; group 3 (titanium), in which a titanium interference screw was used for fixation; group 4 (bioabsorbable), in which a bioabsorbable interference screw was used for fixation. The graft in the press-fit group was harvested with a hollow oscillating saw with inner diameter of 9.4 mm to obtain consistent and completely circular shape of the bone plug. The femoral tunnel with diameter of 8 mm was drilled at the original ACL insertion. Following the bone plug insertion into the femoral tunnel and applying a preload of 20 N, the specimen underwent 500 loading cycles between 0 and 2 mm of displacement. Thereafter the specimen was loaded to failure. There was no fixation site failure during the cyclic loading test. Significant differences in the stiffness, linear load, or failure mode among the groups were not found. The average ultimate failure load of group 1 and group 2 were not significantly different from those of group 3 and group 4. The press-fit groups demonstrated sufficient fixation strength for the rehabilitation and interference screw groups. The completely circular shape of the bone plug and increased diameter difference between the bone plug and the femoral tunnel seemed to contribute to the strong fixation.

  18. The effect of multiple autoclave cycles on the surface of rotary nickel-titanium endodontic files: An in vitro atomic force microscopy investigation.

    PubMed

    Nair, Ashish Shashikant; Tilakchand, Mahima; Naik, Balaram Damodar

    2015-01-01

    To observe and study the effect of multiple autoclave sterilization cycles, on the surface of nickel-titanium (NiTi) files. The file used for this study was the Mtwo file (VDW) and ProTaper (Dentsply). The apical 5 mm of the files were attached to a silicon wafer and subjected to autoclave cycles under standardized conditions. They were scanned with an AFM after 1, 5, and 10 cycles. The unsterilized files were used as control, before start of the study. Three vertical topographic parameters namely maximum height (MH), root mean square (RMS) of surface roughness, and arithmetic mean roughness (AMR)were measured with the atomic force microscope (AFM). Analysis of variance along with Tukey's test was used to test the differences. The vertical topographic parameters were higher for both the files, right after the first cycle, when compared with the control (P < 0.01). The surface roughness increased sharply for Mtwo when compared to ProTaper, though ProTaper had a rougher surface initially. The study confirmed that the irregularities present on the surface of the file became more prominent with multiple autoclave cycles, a fact that should be kept in mind during their reuse.

  19. Polymer taper bridge for silicon waveguide to single mode waveguide coupling

    NASA Astrophysics Data System (ADS)

    Kruse, Kevin; Middlebrook, Christopher T.

    2016-03-01

    Coupling of optical power from high-density silicon waveguides to silica optical fibers for signal routing can incur high losses and often requires complex end-face preparation/processing. Novel coupling device taper structures are proposed for low coupling loss between silicon photonic waveguides and single mode fibers are proposed and devices are fabricated and measured in terms of performance. Theoretical mode conversion models for waveguide tapers are derived for optimal device structure design and performance. Commercially viable vertical and multi-layer taper designs using polymer waveguide materials are proposed as innovative, cost-efficient, and mass-manufacturable optical coupling devices. The coupling efficiency for both designs is determined to evaluate optimal device dimensions and alignment tolerances with both silicon rib waveguides and silicon nanowire waveguides. Propagation loss as a function of waveguide roughness and metallic loss are determined and correlated to waveguide dimensions to obtain total insertion loss for the proposed taper designs. Multi-layer tapers on gold-sputtered substrates are fabricated through photolithography as proof-of-concept devices and evaluated for device loss optimization. Tapered waveguide coupling loss with Si WGs (2.74 dB) was experimentally measured with high correlation to theoretical results.

  20. Early bone growth on the surface of titanium implants in rat femur is enhanced by an amorphous diamond coating.

    PubMed

    Jaatinen, Jarkko J P; Korhonen, Rami K; Pelttari, Alpo; Helminen, Heikki J; Korhonen, Hannu; Lappalainen, Reijo; Kröger, Heikki

    2011-08-01

    Amorphous diamond (AD) is a durable and compatible biomaterial for joint prostheses. Knowledge regarding bone growth on AD-coated implants and their early-stage osseointegration is poor. We investigated bone growth on AD-coated cementless intramedullary implants implanted in rats. Titanium was chosen as a reference due to its well-known performance. We placed AD-coated and non-coated titanium implants (R(a) ≈ 0.2 μm) into the femoral bone marrow of 25 rats. The animals were divided in 2 groups according to implant coating and they were killed after 4 or 12 weeks. The osseointegration of the implants was examined from hard tissue specimens by measuring the new bone formation on their surface. 4 weeks after the operation, the thickness of new bone in the AD-coated group was greater than that in the non-coated group (15.3 (SD 7.1) μm vs. 7.6 (SD 6.0) μm). 12 weeks after the operation, the thickness of new bone was similar in the non-coated group and in the AD-coated group. We conclude that AD coating of femoral implants can enhance bone ongrowth in rats in the acute, early stage after the operation and might be an improvement over earlier coatings.

  1. White light supercontinuum generation in a Y-shaped microstructured tapered fiber pumped at 1064 nm.

    PubMed

    Cascante-Vindas, J; Díez, A; Cruz, J L; Andrés, M V

    2010-07-05

    We report the generation of supercontinuum in a Ge-doped Y-shape tapered fiber pumped at 1064 nm in the ns pump regime. The taper was designed to have long taper transitions and a taper waist with a core diameter of 0.9 mum. The large air-filling fraction and diameter of the air-hole microstructure reduces the confinement loss at long wavelengths so, enabling the extension of the spectrum to longer wavelengths. Along the taper transition the zero-dispersion wavelength decreases as the diameter of the taper becomes smaller. The spectral components generated along the taper transition pump the taper waist, enhancing the generation of short wavelengths. A flat spectrum spanning from 420 nm to 1850 nm is reported.

  2. Cytotoxicity of titanium and titanium alloying elements.

    PubMed

    Li, Y; Wong, C; Xiong, J; Hodgson, P; Wen, C

    2010-05-01

    It is commonly accepted that titanium and the titanium alloying elements of tantalum, niobium, zirconium, molybdenum, tin, and silicon are biocompatible. However, our research in the development of new titanium alloys for biomedical applications indicated that some titanium alloys containing molybdenum, niobium, and silicon produced by powder metallurgy show a certain degree of cytotoxicity. We hypothesized that the cytotoxicity is linked to the ion release from the metals. To prove this hypothesis, we assessed the cytotoxicity of titanium and titanium alloying elements in both forms of powder and bulk, using osteoblast-like SaOS(2) cells. Results indicated that the metal powders of titanium, niobium, molybdenum, and silicon are cytotoxic, and the bulk metals of silicon and molybdenum also showed cytotoxicity. Meanwhile, we established that the safe ion concentrations (below which the ion concentration is non-toxic) are 8.5, 15.5, 172.0, and 37,000.0 microg/L for molybdenum, titanium, niobium, and silicon, respectively.

  3. Femoral Iatrogenic Subtrochanteric Fatigue Fracture Risk is not Increased by Placing Drill Holes Below the Level of the Lesser Trochanter.

    PubMed

    Tsai, Andrew G; Ashworth, Timothy J; Marcus, Randall; Akkus, Ozan

    2017-01-01

    Iatrogenic subtrochanteric fractures of the femur can occur postoperatively following placement of screws in the lateral femoral cortex. Drilling holes below the lesser trochanter is generally avoided to prevent fatigue failure; however, there is little biomechanical evidence to support this recommendation. We hypothesized that hole placement below the level of the lesser trochanter will not accelerate fatigue failure compared to holes at the level of the lesser trochanter. Twelve matched-pairs of male fresh-frozen cadaveric femurs were used for biomechanical testing. A single screw hole was drilled through the lateral femoral cortex either at the level of the lesser trochanter (proximal-hole group) or below the lesser trochanter (distal-hole group). Each femur was cycled to failure using a physiologically-relevant loading model. Paired t-test was used to evaluate for a difference in cycles to failure between groups. There was no statistical difference in cycles to failure between the groups with the hole drilled at or below the lesser trochanter. The traditional recommendation to avoid drilling holes below the level of the lesser trochanter is based mainly on experience and case reports in the literature. The results of this study indicate that placing holes below the level of the lesser trochanter, in and of itself, may not pose any additional risk of fracture. Other important factors need to be considered, such as tapering of the lateral femoral cortex. There are often situations where the patient's anatomy and facture pattern is more conducive to placing a screw distal to the lesser trochanter. This study may allow surgeons greater flexibility in placing screws more distally in the lateral femoral cortex by demonstrating the safety of doing so, at least in the population studied.

  4. Implementation of rectangular slit-inserted ultra-wideband tapered slot antenna.

    PubMed

    Kim, Sun-Woong; Choi, Dong-You

    2016-01-01

    In this paper, a tapered slot antenna capable of ultra-wideband communication was designed. In the proposed antenna, rectangular slits were inserted to enhance the bandwidth and reduce the area of the antenna. The rectangular slit-inserted tapered slot antenna operated at a bandwidth of 8.45 GHz, and the bandwidth improved upon the basic tapered slot antenna by 4.72 GHz. The radiation pattern of the antenna was suitable for location recognition in a certain direction owing to an appropriate 3 dB beam width. The antenna gain was analyzed within the proposed bandwidth, and the highest gain characteristic at 7.55 dBi was exhibited at a 5-GHz band. The simulation and measurement results of the proposed tapered slot antenna were similar.

  5. Vertically-tapered optical waveguide and optical spot transformer formed therefrom

    DOEpatents

    Bakke, Thor; Sullivan, Charles T.

    2004-07-27

    An optical waveguide is disclosed in which a section of the waveguide core is vertically tapered during formation by spin coating by controlling the width of an underlying mesa structure. The optical waveguide can be formed from spin-coatable materials such as polymers, sol-gels and spin-on glasses. The vertically-tapered waveguide section can be used to provide a vertical expansion of an optical mode of light within the optical waveguide. A laterally-tapered section can be added adjacent to the vertically-tapered section to provide for a lateral expansion of the optical mode, thereby forming an optical spot-size transformer for efficient coupling of light between the optical waveguide and a single-mode optical fiber. Such a spot-size transformer can also be added to a III-V semiconductor device by post processing.

  6. Cutting efficiency of conventional and martensitic nickel-titanium instruments for coronal flaring.

    PubMed

    Morgental, Renata Dornelles; Vier-Pelisser, Fabiana Vieira; Kopper, Patrícia Maria Poli; de Figueiredo, José Antonio Poli; Peters, Ove A

    2013-12-01

    This study aimed at evaluating the influence of rotational speed and number of uses on the cutting efficiency of 4 nickel-titanium coronal flaring instruments against 2 substrates, bovine dentin and acrylic blocks. BioRaCe BR0, HyFlex CM1, ProFile OS#2, and ProTaper Sx were used in simulated lateral action against both substrates at 250 and 500 rpm up to 5 times, producing 5 notches in each block. Notch areas and lengths were measured under a stereomicroscope, and data were compared by using parametric tests (α = 0.05). Against both substrates, HyFlex CM1 and ProFile OS#2 were the most and the least cutting efficient instruments, respectively (P < .05). Against acrylic, area and length values at 500 rpm were significantly higher than those at 250 rpm for all brands. Against dentin, significant differences were detected between 250 and 500 rpm for HyFlex CM1 and ProTaper Sx (area) and for BioRace BR0, HyFlex CM1, and ProTaper Sx (length). Regarding cutting efficiency loss, area and length for notches 1 and 2 (first notches) and 4 and 5 (last notches) were similar against acrylic. Against dentin, length values for notches 1 and 2 were significantly higher than those for notches 4 and 5 in ProFile OS#2 and ProTaper Sx. A strong correlation was detected between the overall results obtained on acrylic and dentin for area and length (P < .0001), although further analysis showed that data against acrylic were a poor predictor of data against dentin after repeated use. HyFlex CM1 was the most cutting efficient instrument in lateral action. An increase in rotational speed improved the cutting efficiency. Results against acrylic showed a high correlation to data against dentin, but acrylic may not be a proper substrate when the intention is to assess cutting efficiency loss with repeated use. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. Tapered fiber optical tweezers for microscopic particle trapping: fabrication and application

    NASA Astrophysics Data System (ADS)

    Liu, Zhihai; Guo, Chengkai; Yang, Jun; Yuan, Libo

    2006-12-01

    A novel single tapered fiber optical tweezers is proposed and fabricated by heating and drawing technology. The microscopic particle tapping performance of this special designed tapered fiber probe is demonstrated and investigated. The distribution of the optical field emerging from the tapered fiber tip is numerically calculated based on the beam propagation method. The trapping force FDTD analysis results, both axial and transverse, are also given.

  8. Octave spanning supercontinuum in an As₂S₃ taper using ultralow pump pulse energy.

    PubMed

    Hudson, Darren D; Dekker, Stephen A; Mägi, Eric C; Judge, Alexander C; Jackson, Stuart D; Li, Enbang; Sanghera, J S; Shaw, L B; Aggarwal, I D; Eggleton, Benjamin J

    2011-04-01

    An octave spanning spectrum is generated in an As₂S₃ taper via 77 pJ pulses from an ultrafast fiber laser. Using a previously developed tapering method, we construct a 1.3 μm taper that has a zero-dispersion wavelength around 1.4 μm. The low two-photon absorption of sulfide-based chalcogenide fiber allows for higher input powers than previous efforts in selenium-based chalcogenide tapered fibers. This higher power handling capability combined with input pulse chirp compensation allows an octave spanning spectrum to be generated directly from the taper using the unamplified laser output.

  9. Microdroplet-etched highly birefringent low-loss fiber tapers.

    PubMed

    Mikkelsen, Jared C; Poon, Joyce K S

    2012-07-01

    We use hydrofluoric acid microdroplets to directly etch highly birefringent biconical fiber tapers from standard single-mode fibers. The fiber tapers have micrometer-sized cross sections, which are controlled by the etching condition. The characteristic teardrop cross section leads to a high group birefringence of B(G)≈0.017 and insertion losses <0.7 dB over waist lengths of about 2.1 mm.

  10. Note on performance of tapered grip tensile loading devices

    NASA Technical Reports Server (NTRS)

    Jones, M. H.; Brown, W. F., Jr.

    1975-01-01

    Alignment results are presented in terms of percent bending for a quick release, tapered grip, tensile loading device that has been proposed for testing sharply notched specimens of aluminum and magnesium alloys by a Task Group of the ASTM Committee E-24 on Fracture Testing of Metals. The results show that the bending introduced by the fixtures is strongly dependent on their relative rotational positions in respect to the loading rods which adapt them, to the tensile machine. For one set of tapered grips the highest bending was about 15%. Recommendations are made for improvement in the design of the tapered grips which should reduce the bending stresses substantially.

  11. Development of small bore, high speed tapered roller bearing

    NASA Technical Reports Server (NTRS)

    Morrison, F. R.; Gassel, S. S.; Bovenkerk, R. L.

    1981-01-01

    The performance of four rolling bearing configurations for use on the input pinion shaft of a proposed commercial helicopter transmission was evaluated. The performance characteristics of a high speed tapered roller bearing operating under conditions comparable to those existing at this input pinion shaft were defined. The tapered roller bearing shaft support configuration was developed for the gearbox using commercially available bearing designings. The configuration was optimized and interactive thermomechanically system analyzed. Automotive pinion quality tapered roller bearings were found to be reliable under load and speed conditions in excess of those anticipated in the helicopter transmission. However, it is indicated that the elastohydrodynamic lubricant films are inadequate.

  12. Tapered rib fiber coupler for semiconductor optical devices

    DOEpatents

    Vawter, Gregory A.; Smith, Robert Edward

    2001-01-01

    A monolithic tapered rib waveguide for transformation of the spot size of light between a semiconductor optical device and an optical fiber or from the fiber into the optical device. The tapered rib waveguide is integrated into the guiding rib atop a cutoff mesa type semiconductor device such as an expanded mode optical modulator or and expanded mode laser. The tapered rib acts to force the guided light down into the mesa structure of the semiconductor optical device instead of being bound to the interface between the bottom of the guiding rib and the top of the cutoff mesa. The single mode light leaving or entering the output face of the mesa structure then can couple to the optical fiber at coupling losses of 1.0 dB or less.

  13. Stress intensity factor in a tapered specimen

    NASA Technical Reports Server (NTRS)

    Xue-Hui, L.; Erdogan, F.

    1985-01-01

    The general problem of a tapered specimen containing an edge crack is formulated in terms of a system of singular integral equations. The equations are solved and the stress intensity factor is calculated for a compact and for a slender tapered specimen, the latter simulating the double cantilever beam. The results are obtained primarily for a pair of concentrated forces and for crack surface wedge forces. The stress intensity factors are also obtained for a long strip under uniform tension which contains inclined edge cracks.

  14. Cell Attachment Following Instrumentation with Titanium and Plastic Instruments, Diode Laser, and Titanium Brush on Titanium, Titanium-Zirconium, and Zirconia Surfaces.

    PubMed

    Lang, Melissa S; Cerutis, D Roselyn; Miyamoto, Takanari; Nunn, Martha E

    2016-01-01

    The aim of this study was to evaluate the surface characteristics and gingival fibroblast adhesion of disks composed of implant and abutment materials following brief and repeated instrumentation with instruments commonly used in procedures for implant maintenance, stage-two implant surgery, and periimplantitis treatment. One hundred twenty disks (40 titanium, 40 titaniumzirconium, 40 zirconia) were grouped into treatment categories of instrumentation by plastic curette, titanium curette, diode microlaser, rotary titanium brush, and no treatment. Twenty strokes were applied to half of the disks in the plastic and titanium curette treatment categories, while half of the disks received 100 strokes each to simulate implant maintenance occurring on a repetitive basis. Following analysis of the disks by optical laser profilometry, disks were cultured with human gingival fibroblasts. Cell counts were conducted from scanning electron microscopy (SEM) images. Differences in surface roughness across all instruments tested for zirconia disks were negligible, while both titanium disks and titaniumzirconium disks showed large differences in surface roughness across the spectrum of instruments tested. The rotary titanium brush and the titanium curette yielded the greatest overall mean surface roughness, while the plastic curette yielded the lowest mean surface roughness. The greatest mean cell counts for each disk type were as follows: titanium disks with plastic curettes, titanium-zirconium disks with titanium curettes, and zirconia disks with the diode microlaser. Repeated instrumentation did not result in cumulative changes in surface roughness of implant materials made of titanium, titanium-zirconium, or zirconia. Instrumentation with plastic implant curettes on titanium and zirconia surfaces appeared to be more favorable than titanium implant curettes in terms of gingival fibroblast attachment on these surfaces.

  15. Using a slightly tapered optical fiber to attract and transport microparticles.

    PubMed

    Sheu, Fang-Wen; Wu, Hong-Yu; Chen, Sy-Hann

    2010-03-15

    We exploit a fiber puller to transform a telecom single-mode optical fiber with a 125 microm diameter into a symmetric and unbroken slightly tapered optical fiber with a 50 microm diameter at the minimum waist. When the laser light is launched into the optical fiber, we can observe that, due to the evanescent wave of the slightly tapered fiber, the nearby polystyrene microparticles with 10 microm diameters will be attracted onto the fiber surface and roll separately in the direction of light propagation. We have also simulated and compared the optical propulsion effects on the microparticles when the laser light is launched into a slightly tapered fiber and a heavily tapered (subwavelength) fiber, respectively.

  16. A Volume and Taper Prediction System for Bald Cypress

    Treesearch

    Bernard R. Parresol; James E. Hotvedt; Quang V. Cao

    1987-01-01

    A volume and taper prediction system based on d10 and consisting of a total volume equation, two volume ratio equations (one for diameter limits, the other for height limits), and a taper equation was developed for bald cypress using sample tree data collected in Louisiana. Normal diameter (dn), a subjective variable-...

  17. Varus femoral osteotomy improves sphericity of the femoral head in older children with severe form of Legg-Calvé-Perthes disease.

    PubMed

    Terjesen, Terje; Wiig, Ola; Svenningsen, Svein

    2012-09-01

    In the Norwegian prospective study on Legg-Calvé-Perthes disease (LCPD), we found varus femoral osteotomy gave better femoral head sphericity at a mean of 5 years postoperative than physiotherapy in children older than 6.0 years at diagnosis with femoral head necrosis of more than 50%. That study did not include separate analyses for hips with 100% necrosis and those with a percentage of necrosis between 50% and 100%. We asked whether (1) femoral osteotomy improves femoral head sphericity at followup in all patients with more than 50% femoral head necrosis or in selected groups only and (2) there is a critical age between 6.0 and 10.0 years over which femoral osteotomy does not improve the prognosis. We treated 70 patients with unilateral LCPD, age at diagnosis of more than 6.0 years, and femoral head necrosis of more than 50% with varus femoral osteotomy between 1996 and 2000. We classified necrosis using the Catterall classification. We established a control group of 51 similar children who received physiotherapy. At the 5-year followup visit, the hips were graded according to femoral head shape: spherical, ovoid, or flat. At 5-year followup, there was no difference between the treatment groups in radiographic outcome in Catterall Group 3 hips. In Catterall Group 4 hips, femoral head sphericity was better in the osteotomy group, with flat femoral heads in 14% compared to 75% after physiotherapy. The same trend toward better head sphericity occurred when the lateral pillar classification was used. In children aged 6.0 to 10.0 years, in whom the whole femoral head is affected, femoral head sphericity 5 years after femoral osteotomy was better than that after physiotherapy.

  18. Removal of well-fixed components in femoral revision arthroplasty with controlled segmentation of the proximal femur.

    PubMed

    Megas, Panagiotis; Georgiou, Christos S; Panagopoulos, Andreas; Kouzelis, Antonis

    2014-12-31

    The transfemoral and the extended trochanteric osteotomies are the most common osteotomies used in femoral revision, both when proximal or diaphyseal fixation of the new component has been decided. We present an alternative approach to the trochanteric osteotomies, most frequently used with distally fixated stems, to overcome their shortcomings of osteotomy migration and nonunion, but, most of all, the uncontrollable fragmentation of the femur. The procedure includes a complete circular femoral osteotomy just below the stem tip to prevent distal fracture propagation and a subsequent preplanned segmentation of the proximal femur for better exposure and fast removal of the old prosthesis. The bone fragments are reattached with cerclage wires to the revision prosthesis, which is safely anchored distally. A modified posterolateral approach is used, as the preservation of the continuity of the abductors, the greater trochanter, and the vastus lateralis is a prerequisite. Between 2006 and 2012, 47 stems (33 women, 14 men, mean age 68 years, range 39-88 years) were revised using this technique. They were 12 (26%) stable and 35 (74%) loose prostheses and were all revised to tapered, fluted, grit-blasted stems. No fracture of the trochanters or the distal femur occurred intraoperatively. Mean follow-up was 28 months (range 6-70 months). No case of trochanteric migration or nonunion of the osteotomies was recorded. Restoration of the preexisting bone defects occurred in 83% of the patients. Three patients required repeat revision due to dislocation and one due to a postoperative periprosthetic fracture. None of the failures was attributed to the procedure itself. This new osteotomy technique may seem aggressive at first, but, at least in our hands, has effectively increased the speed of the femoral revision, particularly for the most difficult well-fixed components, but not at the expense of safety.

  19. Numerical simulation of blood flow in femoral perfusion: comparison between side-armed femoral artery perfusion and direct femoral artery perfusion.

    PubMed

    Kitamura, Shingo; Shirota, Minori; Fukuda, Wakako; Inamura, Takao; Fukuda, Ikuo

    2016-12-01

    Computational numerical analysis was performed to elucidate the flow dynamics of femoral artery perfusion. Numerical simulation of blood flow was performed from the right femoral artery in an aortic model. An incompressible Navier-Stokes equation and continuity equation were solved using computed flow dynamics software. Three different perfusion models were analyzed: a 4.0-mm cannula (outer diameter 15 French size), a 5.2-mm cannula (18 French size) and an 8-mm prosthetic graft. The cannula was inserted parallel to the femoral artery, while the graft was anastomosed perpendicular to the femoral artery. Shear stress was highest with the 4-mm cannula (172 Pa) followed by the graft (127 Pa) and the 5.2-mm cannula (99 Pa). The cannula exit velocity was high, even when the 5.2-mm cannula was used. Although side-armed perfusion with an 8-mm graft generated a high shear stress area near the point of anastomosis, flow velocity at the external iliac artery was decreased. The jet speed decreased due to the Coanda effect caused by the recirculation behind sudden expansion of diameter, and the flow velocity maintains a constant speed after the reattachment length of the flow. This study showed that iliac artery shear stress was lower with the 5.2-mm cannula than with the 4-mm cannula when used for femoral perfusion. Side-armed graft perfusion generates a high shear stress area around the anastomotic site, but flow velocity in the iliac artery is slower in the graft model than in the 5.2-mm cannula model.

  20. Femoral head asymmetry and coxa magna: anatomic study.

    PubMed

    Young, Ernest Y; Gebhart, Jeremy J; Bajwa, Navkirat; Cooperman, Daniel R; Ahn, Nicholas U

    2014-06-01

    Coxa magna, the asymmetrical circumferential enlargement of the femoral head, is an important sequela of pediatric disorders such as Legg-Calvé-Perthes disease. Definitions vary because of lack of controls and a scarcity of research on the distribution of the femoral head asymmetry. This study aims at defining the normal distribution of asymmetry between the left and the right femoral head and neck in the population and how demographics affect these properties. The study also looked at the distribution of side dominance (left or right). This study measured 230 paired femurs from individuals (20 to 40 y old) distributed for sex and ethnicity. The height and weight of the individuals were also recorded. The femoral head diameter and minimal femoral neck diameter in the anteroposterior view were measured on each paired femurs. The absolute and percent differences were determined to define asymmetry. Most of the population fell within 3% of asymmetry for the femoral head and 4% for the femoral neck. The maximum head percent asymmetry was 7.4%. Absolute difference in millimeters to percent asymmetry showed a ratio of 2:1 for the femoral head and 3:1 for the femoral neck. African Americans showed greater femoral head symmetry and a bias toward left-sided femoral head and neck enlargement when compared with their white counterparts. There was a high degree of symmetry between the left and right femoral heads and necks, which supports definitions found in the literature that define coxa magna above 10%. This study defines asymmetry in the femoral head in the normal population, which will help to define a quantitative definition of coxa magna.

  1. Characterization of Femoral Component Initial Stability and Cortical Strain in a Reduced Stem-Length Design.

    PubMed

    Small, Scott R; Hensley, Sarah E; Cook, Paige L; Stevens, Rebecca A; Rogge, Renee D; Meding, John B; Berend, Michael E

    2017-02-01

    Short-stemmed femoral components facilitate reduced exposure surgical techniques while preserving native bone. A clinically successful stem should ideally reduce risk for stress shielding while maintaining adequate primary stability for biological fixation. We asked (1) how stem-length changes cortical strain distribution in the proximal femur in a fit-and-fill geometry and (2) if short-stemmed components exhibit primary stability on par with clinically successful designs. Cortical strain was assessed via digital image correlation in composite femurs implanted with long, medium, and short metaphyseal fit-and-fill stem designs in a single-leg stance loading model. Strain was compared to a loaded, unimplanted femur. Bone-implant micromotion was then compared with reduced lateral shoulder short stem and short tapered-wedge designs in cyclic axial and torsional testing. Femurs implanted with short-stemmed components exhibited cortical strain response most closely matching that of the intact femur model, theoretically reducing the potential for proximal stress shielding. In micromotion testing, no difference in primary stability was observed as a function of reduced stem length within the same component design. Our findings demonstrate that within this fit-and-fill stem design, reduction in stem length improved proximal cortical strain distribution and maintained axial and torsional stability on par with other stem designs in a composite femur model. Short-stemmed implants may accommodate less invasive surgical techniques while facilitating more physiological femoral loading without sacrificing primary implant stability. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Multi-objective optimization of hole characteristics during pulsed Nd:YAG laser microdrilling of gamma-titanium aluminide alloy sheet

    NASA Astrophysics Data System (ADS)

    Biswas, R.; Kuar, A. S.; Mitra, S.

    2014-09-01

    Nd:YAG laser microdrilled holes on gamma-titanium aluminide, a newly developed alloy having wide applications in turbine blades, engine valves, cases, metal cutting tools, missile components, nuclear fuel and biomedical engineering, are important from the dimensional accuracy and quality of hole point of view. Keeping this in mind, a central composite design (CCD) based on response surface methodology (RSM) is employed for multi-objective optimization of pulsed Nd:YAG laser microdrilling operation on gamma-titanium aluminide alloy sheet to achieve optimum hole characteristics within existing resources. The three characteristics such as hole diameter at entry, hole diameter at exit and hole taper have been considered for simultaneous optimization. The individual optimization of all three responses has also been carried out. The input parameters considered are lamp current, pulse frequency, assist air pressure and thickness of the job. The responses at predicted optimum parameter level are in good agreement with the results of confirmation experiments conducted for verification tests.

  3. Propagation of atmospheric-pressure ionization waves along the tapered tube

    NASA Astrophysics Data System (ADS)

    Xia, Yang; Wang, Wenchun; Liu, Dongping; Yan, Wen; Bi, Zhenhua; Ji, Longfei; Niu, Jinhai; Zhao, Yao

    2018-02-01

    Gas discharge in a small radius dielectric tube may result in atmospheric pressure plasma jets with high energy and density of electrons. In this study, the atmospheric pressure ionization waves (IWs) were generated inside a tapered tube. The propagation behaviors of IWs inside the tube were studied by using a spatially and temporally resolved optical detection system. Our measurements show that both the intensity and velocity of the IWs decrease dramatically when they propagate to the tapered region. After the taper, the velocity, intensity, and electron density of the IWs are improved with the tube inner diameter decreasing from 4.0 to 0.5 mm. Our analysis indicates that the local gas conductivity and surface charges may play a role in the propagation of the IWs under such a geometrical constraint, and the difference in the dynamics of the IWs after the taper can be related to the restriction in the size of IWs.

  4. Opioid Tapering in Fibromyalgia Patients: Experience from an Interdisciplinary Pain Rehabilitation Program.

    PubMed

    Cunningham, Julie L; Evans, Michele M; King, Susan M; Gehin, Jessica M; Loukianova, Larissa L

    2016-09-01

    Despite current guideline recommendations against the use of opioids for the treatment of fibromyalgia pain, opioid use is reported in approximately 30% of the patient population. There is a lack of information describing the process and results of tapering of chronic opioids. The purpose of this study is to describe opioid tapering and withdrawal symptoms in fibromyalgia patients on opioids. This retrospective research study included a baseline analysis of 159 patients consecutively admitted to the Mayo Clinic Pain Rehabilitation Center from 2006 through 2012 with a pain diagnosis of fibromyalgia completing a 3-week outpatient interdisciplinary pain rehabilitation program. Opioid tapering analysis included 55 (35%) patients using daily opioids. Opioid tapering was individualized to each patient based on interdisciplinary pain rehabilitation team determination. Opioid withdrawal symptoms were assessed daily, utilizing the Clinical Opioid Withdrawal Scale. Patients taking daily opioids had a morphine equivalent mean dose of 99 mg/day. Patients on < 100 mg/day were tapered off over a mean of 10 days compared with patients on > 200 mg/day over a mean of 28 days (P < 0.001). Differences in peak withdrawal symptoms were not statistically significant based on the mean equivalent dose (P = 22). Patients taking opioids for <2 years did not differ in length of tapering (P =0.63) or peak COWS score (P =0.80) compared with >2 years duration. Patients had significant improvements in pain-related measures including numeric pain scores, depression catastrophizing, health perception, interference with life, and perceived life control at program completion. Fibromyalgia patients on higher doses of opioids were tapered off over a longer period of time but no differences in withdrawal symptoms were seen based on opioid dose. Duration of opioid use did not affect the time to complete opioid taper or withdrawal symptoms. Despite opioid tapering, pain-related measures

  5. Tapered fiber Mach-Zehnder interferometers for vibration and elasticity sensing applications.

    PubMed

    Chen, Nan-Kuang; Hsieh, Yu-Hsin; Lee, Yi-Kun

    2013-05-06

    We demonstrate the optical measurements of heart-beat pulse rate and also elasticity of a polymeric tube, using a tapered fiber Mach-Zehnder interferometer. This device has two abrupt tapers in the Er/Yb codoped fiber and thus fractional amount of core mode is converted into cladding modes at the first abrupt taper. The core and cladding modes propagate through different optical paths and meet again at the second abrupt taper to produce interferences. The mechanical vibration signals generated by the blood vessels and by an inflated polymeric tube can perturb the optical paths of resonant modes to move around the resonant wavelengths. Thus, the cw laser signal is modulated to become pulses to reflect the heart-beat pulse rate and the elasticity of a polymeric tube, respectively.

  6. [Ex vivo microCT analysis of possible microfractures of the femoral head during implantation of a cementless hip resurfacing femoral component].

    PubMed

    Lerch, M; Olender, G; von der Höh, N; Thorey, F; von Lewinski, G; Meyer-Lindenberg, A; Windhagen, H; Hurschler, C

    2009-01-01

    Microfractures of the femoral head during implantation of the femoral components are suspected to be a cause of fractures at the implant/neck junction which represent a common failure mode in hip resurfacing arthroplasty. Callus formation observed in femoral head retrievals suggests the occurrence of microfractures inside the femoral head, which might be inadvertently caused by the surgeon during implantation. The aim of this biomechanical study was to analyse whether or not the implantation of a cementless femoral component hip resurfacing system causes microfractures in the femoral head. After the preparation of 20 paired human cadaveric femoral heads, the cementless femoral component ESKA Typ BS (ESKA Implants GmbH & Co., Lübeck) was implanted on 9 specimens with an impaction device that generates 4.5 kN impaction force. On 9 specimens the femoral component was implanted by hand. One head was used as a fracture model, 1 specimen served as control without manipulation. The femoral component used for impaction was equipped with hinges to enable its removal without further interfering with the bone stock. Specimens were scanned with a microCT device before and after impaction and the microCT datasets before and after impaction were compared to identify possible microfractures. Twenty strikes per hand or with the impaction device provided sufficient implant seating. Neither the macroscopic examination nor the 2-dimensional microCT analysis revealed any fractures of the femoral heads after impaction. At least macroscopically and in the 2-dimensional microCT analysis, implantation of the cementless hip resurfacing femoral component ESKA Typ BS with 4.5 kN or by hand does not seem to cause fractures of the femoral head. Georg Thieme Verlag KG Stuttgart, New York.

  7. Supercompensation Kinetics of Physical Qualities During a Taper in Team-Sport Athletes.

    PubMed

    Marrier, Bruno; Robineau, Julien; Piscione, Julien; Lacome, Mathieu; Peeters, Alexis; Hausswirth, Christophe; Morin, Jean-Benoît; Le Meur, Yann

    2017-10-01

    Peaking for major competition is considered critical for maximizing team-sport performance. However, there is little scientific information available to guide coaches in prescribing efficient tapering strategies for team-sport players. To monitor the changes in physical performance in elite team-sport players during a 3-wk taper after a preseason training camp. Ten male international rugby sevens players were tested before (Pre) and after (Post) a 4-wk preseason training camp focusing on high-intensity training and strength training with moderate loads and once each week during a subsequent 3-wk taper. During each testing session, midthigh-pull maximal strength, sprint-acceleration mechanical outputs, and performance, as well as repeated-sprint ability (RSA), were assessed. At Post, no single peak performance was observed for maximal lower-limb force output and sprint performance, while RSA peaked for only 1 athlete. During the taper, 30-m-sprint time decreased almost certainly (-3.1% ± 0.9%, large), while maximal lower-limb strength and RSA, respectively, improved very likely (+7.7% ± 5.3%, small) and almost certainly (+9.0% ± 2.6%, moderate). Of the peak performances, 70%, 80%, and 80% occurred within the first 2 wk of taper for RSA, maximal force output, and sprint performance, respectively. These results show the sensitivity of physical qualities to tapering in rugby sevens players and suggest that an ~1- to 2-wk tapering time frame appears optimal to maximize the overall physical-performance response.

  8. Ultrasound-guided placement of a permanent percutaneous femoral nerve stimulator leads for the treatment of intractable femoral neuropathy.

    PubMed

    Narouze, Samer N; Zakari, Adel; Vydyanathan, Amaresh

    2009-01-01

    Femoral nerve injury is a rare complication of cardiac catheterization and is usually caused by direct trauma during femoral artery access, compression from a hematoma, or prolonged digital pressure for post-procedural hemostasis. Peripheral nerve stimulation has been used to treat different pain syndromes in the upper and lower extremities with variable success and it typically requires direct vision with open surgical approach. Since the femoral nerve can be readily seen with ultrasonography, an ultrasound-guided lead placement seemed practical. A 61-year-old morbidly obese male who sustained femoral nerve injury during cardiac catheterization continued to complain of intractable femoral neuropathy 18 months afterwords. He failed multiple treatment modalities and continued to complain of severe neuropathic pains that markedly interfere with his daily activities. Two percutaneous leads were placed under real-time ultrasonography and the placement was confirmed with fluoroscopy. One lead was placed along the longitudinal axis of the nerve and the patient had good coverage over the anterior thigh but not below the knee. So another lead was placed horizontally across the femoral nerve in order to stimulate all the branches and the patient reported good coverage along the saphenous nerve distribution down to the foot. The patient continues to be pain free 20 months after the implant. Here we described a novel non-invasive percutaneous approach for femoral nerve stimulation with ultrasound guidance which allowed precise placement of the stimulating lead very close to the femoral nerve without the need for surgical exploration.

  9. Do NiTi instruments show defects before separation? Defects caused by torsional fatigue in hand and rotary nickel-titanium (NiTi) instruments which lead to failure during clinical use.

    PubMed

    Chakka, N V Murali Krishna; Ratnakar, P; Das, Sanjib; Bagchi, Anandamy; Sudhir, Sudhir; Anumula, Lavanya

    2012-11-01

    Visual and microscopic evaluation of defects caused by torsional fatigue in hand and rotary nickel titanium (NiTi) instruments. Ninety-six NiTi greater taper instruments which were routinely used for root canal treatment only in anterior teeth were selected for the study. The files taken include ProTaper for hand use, ProTaper Rotary files and Endowave rotary files. After every use, the files were observed visually and microscopically (Stereomicroscope at 10×) to evaluate the defects caused by torsional fatigue. Scoring was given according to a new classification formulated which gives an indication of the severity of the defect or damage. Data was statistically analyzed using KruskallWallis and Mann-Whitney U test. Number of files showing defects were more under stereomicroscope than visual examination. But, the difference in the evaluation methods was not statistically significant. The different types of defects observed were bent instrument, straightening/stretching of twist contour and partial reverse twisting. Endowave files showed maximum number of defects followed by ProTaper for hand use and least in ProTaper Rotary. Visible defects due to torsional fatigue do occur in NiTi instruments after clinical use. Both visual and microscopic examinations were efficient in detecting defects caused due to torsional fatigue. This study emphasizes that all files should be observed for any visible defects before and after every instrumentation cycle to minimize the risk of instrument separation and failure of endodontic therapy.

  10. Tapered Roller Bearing Damage Detection Using Decision Fusion Analysis

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Kreider, Gary; Fichter, Thomas

    2006-01-01

    A diagnostic tool was developed for detecting fatigue damage of tapered roller bearings. Tapered roller bearings are used in helicopter transmissions and have potential for use in high bypass advanced gas turbine aircraft engines. A diagnostic tool was developed and evaluated experimentally by collecting oil debris data from failure progression tests conducted using health monitoring hardware. Failure progression tests were performed with tapered roller bearings under simulated engine load conditions. Tests were performed on one healthy bearing and three pre-damaged bearings. During each test, data from an on-line, in-line, inductance type oil debris sensor and three accelerometers were monitored and recorded for the occurrence of bearing failure. The bearing was removed and inspected periodically for damage progression throughout testing. Using data fusion techniques, two different monitoring technologies, oil debris analysis and vibration, were integrated into a health monitoring system for detecting bearing surface fatigue pitting damage. The data fusion diagnostic tool was evaluated during bearing failure progression tests under simulated engine load conditions. This integrated system showed improved detection of fatigue damage and health assessment of the tapered roller bearings as compared to using individual health monitoring technologies.

  11. Mechanics of the tapered interference fit in dental implants.

    PubMed

    Bozkaya, Dinçer; Müftü, Sinan

    2003-11-01

    In evaluation of the long-term success of a dental implant, the reliability and the stability of the implant-abutment interface plays a great role. Tapered interference fits provide a reliable connection method between the abutment and the implant. In this work, the mechanics of the tapered interference fits were analyzed using a closed-form formula and the finite element (FE) method. An analytical solution, which is used to predict the contact pressure in a straight interference, was modified to predict the contact pressure in the tapered implant-abutment interface. Elastic-plastic FE analysis was used to simulate the implant and abutment material behavior. The validity and the applicability of the analytical solution were investigated by comparisons with the FE model for a range of problem parameters. It was shown that the analytical solution could be used to determine the pull-out force and loosening-torque with 5-10% error. Detailed analysis of the stress distribution due to tapered interference fit, in a commercially available, abutment-implant system was carried out. This analysis shows that plastic deformation in the implant limits the increase in the pull-out force that would have been otherwise predicted by higher interference values.

  12. A Survey on Nickel Titanium Rotary Instruments and their Usage Techniques by Endodontists in India.

    PubMed

    Patil, Thimmanagowda N; Saraf, Prahlad A; Penukonda, Raghavendra; Vanaki, Sneha S; Kamatagi, Laxmikant

    2017-05-01

    The preference and usage of nickel titanium rotary instruments varies from individual to individual based on their technique, experience with the rotary systems and the clinical situation. Very limited information is available to explain the adoption of changing concepts with respect to nickel titanium rotary instruments pertaining to the endodontists in India. The aim of this study was to conduct a questionnaire survey to acquire the knowledge concerning different NiTi rotary instruments and their usage techniques by endodontists in India. A Survey questionnaire was designed which consisted of 32 questions regarding designation, demographics, experience with rotary instruments, usage of different file systems, usage techniques, frequency of reuse, occurrence of file fracture, reasons and their management was distributed by hand in the national postgraduate convention and also disseminated via electronic medium to 400 and 600 endodontists respectively. Information was collected from each individual to gain insight into the experiences and beliefs of endodontists concerning the new endodontic technology of rotary NiTi instrumentation based on their clinical experience with the rotary systems. The questions were designed to ascertain the problems, patterns of use and to identify areas of perceived or potential concern regarding the rotary instruments and the data acquired was statistically evaluated using Fisher's-exact test and the Chi-Square test. Overall 63.8% (638) endodontists responded. ProTaper was one of the most commonly used file system followed by M two and ProTaper Next. There was a significant co relation between the years of experience and the file re use frequency, preparation technique, file separation, management of file separation. A large number of Endodontists prefer to reuse the rotary NiTi instruments. As there was an increase in the experience, the incidence of file separation reduced with increasing number of re use frequency and with

  13. Effect of Instrumentation Techniques and Preparation Taper on Apical Extrusion of Bacteria.

    PubMed

    Aksel, Hacer; Küçükkaya Eren, Selen; Çakar, Aslı; Serper, Ahmet; Özkuyumcu, Cumhur; Azim, Adham A

    2017-06-01

    The aim of this in vitro study was to evaluate the effects of different root canal instrumentation techniques and preparation tapers on the amount of apically extruded bacteria. The root canals of 98 extracted human mandibular incisors were contaminated with Enterococcus faecalis suspension. After incubation at 37°C for 24 hours, the root canals were instrumented with K3 rotary files in a crown-down (CD) or full-length linear instrumentation technique (FL) by using 3 different root canal tapers (0.02, 0.04, and 0.06). During instrumentation, apically extruded bacteria were collected into vials containing saline solution. The microbiological samples were taken from the vials and incubated in brain-heart agar medium for 24 hours, and the numbers of colony-forming units (CFUs) were determined. The obtained results were analyzed with t test and one-way analysis of variance for the comparisons between the instrumentation techniques (CD and FL) and the preparation tapers (0.02, 0.04, and 0.06), respectively. Tukey honestly significant difference test was used for pairwise comparisons. The preparation taper had no effect on the number of CFUs when a FL instrumentation technique was used (P > .05). There was a statistically significant difference in the CFUs between FL and CD techniques when the preparation taper was 0.02 (P < .05). There was no statistically significant difference between the 0.04 and 0.06 preparation tapers in any of the instrumentation techniques (P > .05). Using a 0.02 taper in a CD manner results in the least amount of bacterial extrusion. The instrumentation technique did not seem to affect the amount of bacterial extrusion when 0.04 and 0.06 taper instruments were used for cleaning and shaping the root canal space. Published by Elsevier Inc.

  14. The effect of multiple autoclave cycles on the surface of rotary nickel-titanium endodontic files: An in vitro atomic force microscopy investigation

    PubMed Central

    Nair, Ashish Shashikant; Tilakchand, Mahima; Naik, Balaram Damodar

    2015-01-01

    Aims: To observe and study the effect of multiple autoclave sterilization cycles, on the surface of nickel-titanium (NiTi) files. Materials and Methods: The file used for this study was the Mtwo file (VDW) and ProTaper (Dentsply). The apical 5 mm of the files were attached to a silicon wafer and subjected to autoclave cycles under standardized conditions. They were scanned with an AFM after 1, 5, and 10 cycles. The unsterilized files were used as control, before start of the study. Three vertical topographic parameters namely maximum height (MH), root mean square (RMS) of surface roughness, and arithmetic mean roughness (AMR)were measured with the atomic force microscope (AFM). Analysis of variance along with Tukey's test was used to test the differences. Results: The vertical topographic parameters were higher for both the files, right after the first cycle, when compared with the control (P < 0.01). The surface roughness increased sharply for Mtwo when compared to ProTaper, though ProTaper had a rougher surface initially. Conclusions: The study confirmed that the irregularities present on the surface of the file became more prominent with multiple autoclave cycles, a fact that should be kept in mind during their reuse. PMID:26069408

  15. Titanium

    USGS Publications Warehouse

    Bedinger, G.M.

    2013-01-01

    Titanium is the ninth most abundant element in the earth’s crust and can be found in nearly all rocks and sediments. It is a lithophile element with a strong affinity for oxygen and is not found as a pure metal in nature. Titanium was first isolated as a pure metal in 1910, but it was not until 1948 that metal was produced commercially using the Kroll process (named after its developer, William Kroll) to reduce titanium tetrachloride with magnesium to produce titanium metal.

  16. Thread gauge for tapered threads

    DOEpatents

    Brewster, Albert L.

    1994-01-11

    The thread gauge permits the user to determine the pitch diameter of tapered threads at the intersection of the pitch cone and the end face of the object being measured. A pair of opposed anvils having lines of threads which match the configuration and taper of the threads on the part being measured are brought into meshing engagement with the threads on opposite sides of the part. The anvils are located linearly into their proper positions by stop fingers on the anvils that are brought into abutting engagement with the end face of the part. This places predetermined reference points of the pitch cone of the thread anvils in registration with corresponding points on the end face of the part being measured, resulting in an accurate determination of the pitch diameter at that location. The thread anvils can be arranged for measuring either internal or external threads.

  17. Thread gauge for tapered threads

    DOEpatents

    Brewster, A.L.

    1994-01-11

    The thread gauge permits the user to determine the pitch diameter of tapered threads at the intersection of the pitch cone and the end face of the object being measured. A pair of opposed anvils having lines of threads which match the configuration and taper of the threads on the part being measured are brought into meshing engagement with the threads on opposite sides of the part. The anvils are located linearly into their proper positions by stop fingers on the anvils that are brought into abutting engagement with the end face of the part. This places predetermined reference points of the pitch cone of the thread anvils in registration with corresponding points on the end face of the part being measured, resulting in an accurate determination of the pitch diameter at that location. The thread anvils can be arranged for measuring either internal or external threads. 13 figures.

  18. Optimised process for fabricating tapered long period gratings

    NASA Astrophysics Data System (ADS)

    Mullaney, K.; Staines, S. E.; James, S. W.; Tatam, R. P.

    2017-04-01

    The process of fabricating tapered long period gratings (TLPGs) using a CO2 laser is described. TLPGs with a period spacing of 378 μm, were fabricated by optimization of the taper waist diameter and careful control of the duty-cycle and its uniformity along the length of the grating. The 6-period TLPGs exhibited a pass-band insertion loss of 0.6 dB, resonance band extinction values of 3 dB and had a physical length of 2.27 mm.

  19. Measuring the charge density of a tapered optical fiber using trapped microparticles.

    PubMed

    Kamitani, Kazuhiko; Muranaka, Takuya; Takashima, Hideaki; Fujiwara, Masazumi; Tanaka, Utako; Takeuchi, Shigeki; Urabe, Shinji

    2016-03-07

    We report the measurements of charge density of tapered optical fibers using charged particles confined in a linear Paul trap at ambient pressure. A tapered optical fiber is placed across the trap axis at a right angle, and polystyrene microparticles are trapped along the trap axis. The distance between the equilibrium position of a positively charged particle and the tapered fiber is used to estimate the amount of charge per unit length of the fiber without knowing the amount of charge of the trapped particle. The charge per unit length of a tapered fiber with a diameter of 1.6 μm was measured to be 2-1+3×10 -11 C/m.

  20. Effects of MgO and SiO2 on Plasma-Sprayed Hydroxyapatite Coating: An in Vivo Study in Rat Distal Femoral Defects.

    PubMed

    Ke, Dongxu; Robertson, Samuel F; Dernell, William S; Bandyopadhyay, Amit; Bose, Susmita

    2017-08-09

    Plasma-sprayed hydroxyapatite (HA)-coated titanium implants have been widely used in orthopedic applications due to their inheritance of an excellent mechanical property from titanium and great osteoconductivity from HA. However, the lack of osteoinductivity limits their further applications. In this study, 1 wt % MgO and 0.5 wt % SiO 2 were mixed with HA for making plasma-sprayed coatings on titanium implants. Plasma-sprayed HA- and MgO/SiO 2 -HA-coated titanium implants showed adhesive bond strengths of 25.73 ± 1.92 and 23.44 ± 2.89 MPa, respectively. The presence of MgO and SiO 2 significantly increased the osteogenesis, osseointegration, and bone mineralization of HA-coated titanium implants by the evaluation of their histomorphology after 6, 10, and 14 weeks of implantation in rat distal femoral defects. Implant pushout tests also showed a shear modulus of 149.83 ± 3.69 MPa for MgO/SiO 2 -HA-coated implants after 14 weeks of implantation, compared to 52.68 ± 10.41 MPa for uncoated implants and 83.92 ± 3.68 MPa for pure HA-coated implants; These are differences in the shear modulus of 96% and 56.4%, respectively. This study assesses for the first time the quality of the bone-implant interface of induction plasma-sprayed MgO and SiO 2 binary-doped HA coatings on load-bearing implants compared to bare titanium and pure HA coatings in a quantitative manner. Relating the osseointegration and interface shear modulus to the quality of implant fixation is critical to the advancement and implementation of HA-coated orthopedic implants.

  1. A Tree Taper Model Based on Similar Triangles and Use of Crown Ratio as a Measure of Form in Taper Equations for Longleaf Pine

    Treesearch

    Dennis J. Shaw; Ralph S. Meldahl; John S. Kush; Greg L. Somers

    2003-01-01

    We used data from 322 natural longleaf pine (Pinus palustris Mill.) trees to include crown ratio as a continuous variable in taper equations. The data were divided into 10 crown-ratio classes and fitted taper equations into each class to detect trends in the coefficients. For application to longleaf pine, we replaced coefficients that exhibited a...

  2. Misalignment tolerant efficient inverse taper coupler for silicon waveguide

    NASA Astrophysics Data System (ADS)

    Wang, Peng; Michael, Aron; Kwok, Chee Yee; Chen, Ssu-Han

    2015-12-01

    This paper describes an efficient fiber to submicron silicon waveguide coupling based on an inversely tapered silicon waveguide embedded in a SiO2 waveguide that is suspended in air. The inverse taper waveguide consist of a 50um long and 240nm thick silicon that linearly taper in width from 500nm to 120nm, which is embedded in SiO2. The SiO2 waveguide is 6um wide and 10um long. The simulation results show that the coupling loss of this new approach is 2.7dB including the interface loss at the input and output. The tolerance to fiber misalignment at the input of the coupler is 2um in both horizontal and vertical directions for only 1.5dB additional loss.

  3. Canal wall planning by engine-driven nickel-titanium instruments, compared with stainless-steel hand instrumentation.

    PubMed

    Tucker, D M; Wenckus, C S; Bentkover, S K

    1997-03-01

    Twenty-two mesial roots of extracted human mandibular molars were divided into two groups based on root curvature and length. The mesiolingual canals were instrumented using either Flexofiles in a step-back anticurvature filing method, or they were instrumented with engine-driven 0.02 taper nickel-titanium files. Ground sections were prepared at 1-, 2.5-, and 5-mm levels from the working length. The mesiobuccal canal was used as an uninstrumented control for predentin character. Digitizing software was used to calculate the instrumented portion as a percentage of the total canal perimeter. The results indicated no significant difference in overall canal wall planning between the two groups and no significant difference at each of the three levels.

  4. Incidence of apical crack initiation and propagation during the removal of root canal filling material with ProTaper and Mtwo rotary nickel-titanium retreatment instruments and hand files.

    PubMed

    Topçuoğlu, Hüseyin Sinan; Düzgün, Salih; Kesim, Bertan; Tuncay, Oznur

    2014-07-01

    The aim of this study was to determine the incidence of crack initiation and propagation in apical root dentin after retreatment procedures performed by using 2 rotary retreatment systems and hand files with additional instrumentation. Eighty extracted mandibular premolars with single canals were selected. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the control group, and no preparation was performed. The remaining 60 teeth were prepared to size 35 with rotary files and filled with gutta-percha and AH Plus sealer. Specimens were then divided into 3 groups (n = 20), and retreatment procedures were performed with the following devices and techniques: ProTaper Universal retreatment files, Mtwo retreatment files, and hand files. After retreatment, the additional instrumentation was performed by using size 40 ProTaper, Mtwo, and hand files. Digital images of the apical root surface were recorded before preparation, after instrumentation, after filling, after retreatment, and after additional instrumentation. The images were then inspected for the presence of any new apical cracks and propagation. Data were analyzed with the logistic regression and Fisher exact tests. All experimental groups caused crack initiation and propagation after use of retreatment instruments. The ProTaper and Mtwo retreatment groups caused greater crack initiation and propagation than the hand instrument group (P < .05) after retreatment. Additional instrumentation with ProTaper and Mtwo instruments after the use of retreatment instruments caused crack initiation and propagation, whereas hand files caused neither crack initiation nor propagation (P < .05). This study showed that retreatment procedures and additional instrumentation after the use of retreatment files may cause crack initiation and propagation in apical dentin. Copyright © 2014 American Association of Endodontists

  5. A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study

    PubMed Central

    Shankarappa, Pushpa; Misra, Abhinav; Sawhney, Asheesh; Sridevi, Nandamuri; Singh, Anu

    2016-01-01

    Introduction. The aim of the present study was to evaluate the dentinal cracks after root canal preparation with rotary files: Gates Glidden, ProTaper Universal, ProTaper Next, and HyFlex CM at different instrumentation lengths. Methodology. Sixty-five mandibular premolars were mounted in the acrylic tube with simulated periodontal ligaments and the apex was exposed. The root canals were instrumented with different rotary files, namely, ProTaper Universal, ProTaper Next, and HyFlex CM, to the major apical foramen (AF), short AF, and beyond AF. The root apex was stained with 1% methylene blue dye and digital images of apical surface of every tooth were taken and development of dentinal defects was determined by using stereomicroscope. Multinomial logistic regression test was performed to identify influencing factors. Results. Instrumentation with rotary files terminated 2 mm short AF and did not cause any cracks. Significantly less cracks were seen when instrumentation with rotary files terminated 1 mm short apical foramen when compared with the instrumentation terminated at or beyond apical foramen (p < 0.05). Conclusion. ProTaper Universal rotary files caused more dentinal cracks than ProTaper Next and HyFlex CM. Instrumentation short AF reduced the risk of dentinal defects. PMID:27446636

  6. Self-designed femoral neck guide pin locator for femoral neck fractures.

    PubMed

    Xia, Shengli; Wang, Ziping; Wang, Minghui; Wu, Zuming; Wang, Xiuhui

    2014-01-01

    Closed reduction and fixation with 3 cannulated screws is a widely accepted surgery for the treatment of femoral neck fractures. However, how to obtain optimal screw placement remains unclear. In the current study, the authors designed a guide pin positioning system for femoral neck fracture cannulated screw fixation and examined its application value by comparing it with freehand guide needle positioning and with general guide pin locator positioning provided by equipment manufacturers. The screw reset rate, screw parallelism, triangle area formed by the link line of the entry point of 3 guide pins, and maximum vertical load bearing of the femoral neck after internal fixation were recorded. As expected, the triangle area was largest in the self-designed positioning group, followed by the general positioning group and the freehand positioning group. The difference among the 3 groups was statistically significant (P<.05). Anteroposterior and lateral radiographs showed that the screws were more parallel in the self-designed positioning group and general positioning group compared with the freehand positioning group (P<.05). The screw reset rate in the self-designed positioning group was significantly lower than that in the general positioning group and the freehand positioning group (P<.05). Maximum bearing load among the 3 groups was equivalent, showing no statistically significant difference (P>.05). The authors’ self-designed guide pin positioning system has the potential to accurately insert cannulated screws in femoral neck fractures and may reduce bone loss and unnecessary radiation.

  7. Finite element analysis on the biomechanical stability of open porous titanium scaffolds for large segmental bone defects under physiological load conditions.

    PubMed

    Wieding, Jan; Souffrant, Robert; Mittelmeier, Wolfram; Bader, Rainer

    2013-04-01

    Repairing large segmental defects in long bones caused by fracture, tumour or infection is still a challenging problem in orthopaedic surgery. Artificial materials, i.e. titanium and its alloys performed well in clinical applications, are plenary available, and can be manufactured in a wide range of scaffold designs. Although the mechanical properties are determined, studies about the biomechanical behaviour under physiological loading conditions are rare. The goal of our numerical study was to determine the suitability of open-porous titanium scaffolds to act as bone scaffolds. Hence, the mechanical stability of fourteen different scaffold designs was characterized under both axial compression and biomechanical loading within a large segmental distal femoral defect of 30mm. This defect was stabilized with an osteosynthesis plate and physiological hip reaction forces as well as additional muscle forces were implemented to the femoral bone. Material properties of titanium scaffolds were evaluated from experimental testing. Scaffold porosity was varied between 64 and 80%. Furthermore, the amount of material was reduced up to 50%. Uniaxial compression testing revealed a structural modulus for the scaffolds between 3.5GPa and 19.1GPa depending on porosity and material consumption. The biomechanical testing showed defect gap alterations between 0.03mm and 0.22mm for the applied scaffolds and 0.09mm for the intact bone. Our results revealed that minimizing the amount of material of the inner core has a smaller influence than increasing the porosity when the scaffolds are loaded under biomechanical loading. Furthermore, an advanced scaffold design was found acting similar as the intact bone. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Taper of wood poles

    Treesearch

    Billy Bohannan; Hermann Habermann; Joan E. Lengel

    1974-01-01

    Round wood pole use has changed without accompanying advancement in engineering design data. Previous pole design was based on the assumption that maximum stress occurred at the groundline but, with the larger poles that are now being used, maximum stress may occur along the pole length. For accurate engineering analysis the shape or taper of a pole must be known. Both...

  9. Dwarf mistletoe does not increase trunk taper in released red firs in California

    Treesearch

    Robert F. Scharpf

    1977-01-01

    Dwarf mistletoe had no noticeable effect on trunk taper of young, dominant and codominant red firs 4 to 22 inches (10.2 to 55.9 cm) d.b.h. Also, taper was not influenced by live crown ratio of infected and uninfected trees. Trees less than 7 inches d.b.h. had significantly more taper than larger trees, irrespective of dwarf mistletoe.

  10. Radiological evaluation of the morphological changes of root canals shaped with ProTaper for hand use and the ProTaper and RaCe rotary instruments.

    PubMed

    Aguiar, Carlos M; Câmara, Andréa C

    2008-12-01

    This study evaluated, by means of the radiography examination, the occurrence of deviations in the apical third of root canals shaped with hand and rotary instruments. Sixty mandibular human molars were divided into three groups. The root canals in group 1 were instrumented with ProTaper (Dentsply/Maillefer, Ballaigues, Switzerland) for hand use, group 2 with ProTaper and group 3 with RaCe. The images obtained by double superimposition of the pre- and postoperative radiographs were evaluated by two endodontists with the aid of a magnifier-viewer and a fivefold magnifier. Statistical analysis was performed using the Fisher-Freeman-Halton. The instrumentation using the ProTaper for hand use showed 25% of the canals with a deviation in the apical third, as did the ProTaper, while the corresponding figure for the RaCe (FKG Dentaire, La-Chaux-de-Fonds, Switzerland) was 20%, but these results were not statistically significant. There was no correlation between the occurrence of deviations in the apical third and the systems used.

  11. High-brightness tapered laser diodes with photonic crystal structures

    NASA Astrophysics Data System (ADS)

    Li, Yi; Du, Weichuan; Kun, Zhou; Gao, Songxin; Ma, Yi; Tang, Chun

    2018-02-01

    Beam quality of tapered laser diodes is limited by higher order lateral mode. On purpose of optimizing the brightness of tapered laser diodes, we developed a novel design of tapered diodes. This devices based on InGaAs/AlGaAs asymmetry epitaxial structure, containing higher order lateral mode filtering schemes especially photonic crystal structures, which fabricated cost effectively by using standard photolithography and dry etch processes. Meanwhile, the effects of photonic crystal structures on mode control are also investigated theoretically by FDBPM (Finite-Difference Beam Propagation Method) calculation. We achieved a CW optical output power of 6.9W at 940nm for a single emitter with 4 mm cavity length. A nearly diffraction limited beam of M2 ≍1.9 @ 0.5W has been demonstrated, and a highest brightness of β =75MW/(cm2 ·sr) was reached.

  12. Supercontinuum generation from 437 to 2850 nm in a tapered fluorotellurite microstructured fiber

    NASA Astrophysics Data System (ADS)

    Wang, F.; Jia, Z. X.; Yao, C. F.; Wang, S. B.; Hu, M. L.; Wu, C. F.; Ohishi, Y.; Qin, W. P.; Qin, G. S.

    2016-12-01

    We demonstrated supercontinuum (SC) generation in a tapered fluorotellurite microstructured fiber (MF) with a sub-micrometer core diameter. Fluorotellurite MFs based on TeO2-BaF2-Y2O3 glasses were fabricated by using a rod-in-tube method and a tapered fluorotellurite MF with a minimum core diameter of ~0.65 µm was prepared by employing a tapering system. A 1560 nm femtosecond fiber laser was used as the pumping source. With increasing the peak power of the launched pump laser to ~11 kW, SC light expanding from 437 to 2850 nm was generated in the tapered fluorotellurite MF. In addition, relatively strong blue-shifted dispersive wave at ~489 nm was also observed from the tapered fluorotellurite MF.

  13. Suitability of Secondary PEEK Telescopic Crowns on Zirconia Primary Crowns: The Influence of Fabrication Method and Taper.

    PubMed

    Merk, Susanne; Wagner, Christina; Stock, Veronika; Eichberger, Marlis; Schmidlin, Patrick R; Roos, Malgorzata; Stawarczyk, Bogna

    2016-11-08

    This study investigates the retention load (RL) between ZrO₂ primary crowns and secondary polyetheretherketone (PEEK) crowns made by different fabrication methods with three different tapers. Standardized primary ZrO₂ crowns were fabricated with three different tapers: 0°, 1°, and 2° ( n = 10/group). Ten secondary crowns were fabricated (i) milled from breCam BioHPP blanks (PM); (ii) pressed from industrially fabricated PEEK pellets (PP) (BioHPP Pellet); or (iii) pressed from granular PEEK (PG) (BioHPP Granulat). One calibrated operator adjusted all crowns. In total, the RL of 90 secondary crowns were measured in pull-off tests at 50 mm/min, and each specimen was tested 20 times. Two- and one-way ANOVAs followed by a Scheffé's post-hoc test were used for data analysis ( p < 0.05). Within crowns with a 0° taper, the PP group showed significantly higher retention load values compared with the other groups. Among the 1° taper, the PM group presented significantly lower retention loads than the PP group. However, the pressing type had no impact on the results. Within the 2° taper, the fabrication method had no influence on the RL. Within the PM group, the 2° taper showed significantly higher retention load compared with the 1° taper. The taper with 0° was in the same range value as the 1° and 2° tapers. No impact of the taper on the retention value was observed between the PP groups. Within the PG groups, the 0° taper presented significantly lower RL than the 1° taper, whereas the 2° taper showed no differences. The fabrication method of the secondary PEEK crowns and taper angles showed no consistent effect within all tested groups.

  14. [Evaluation of preparation of curved root canals using hand-used ProTaper].

    PubMed

    Nie, Min; Zhao, Xin-Chen; Peng, Bin; Fan, Ming-Wen; Bian, Zhuan

    2009-05-01

    To evaluate the shaping ability of hand-used ProTaper on curved canals using Endodontic Cube. Fifty-four curved root canals in vitro were selected and divided into three groups according to the curved degree (alpha), group A: 0 degrees < or = alpha < 25 degrees , group B: 25 degrees < or = alpha < 40 degrees , group C: 40 degrees < or = alpha < 55 degrees . Endodontic Cube was assembled, and each sample was sectioned perpendicular to the axis of the tooth into four sections with Isomer-Buhler in low speed. Then the root canals were prepared with hand-used ProTaper. Before and after shaping, photograph of all the sections were taken under a stereomicroscope. Statistical analyses were performed. The dentin cutting quantity of the whole canal prepared with ProTaper in group B and C was larger than that of group A. The deviation distance of the whole canal prepared by ProTaper in group C was significantly larger than that in group A, and the deviation distance in middle portion larger than that in group B. The maintaining ability in the middle portion of group C by ProTaper was worse than that of group A and B. The curvature of root canal may increase the cutting quantity of the -dentin and reduce the ability of remaining original canal shape prepared by ProTaper.

  15. Tuning micropillar tapering for optimal friction performance of thermoplastic gecko-inspired adhesive.

    PubMed

    Kim, Yongkwan; Chung, Yunsie; Tsao, Angela; Maboudian, Roya

    2014-05-14

    We present a fabrication method and friction testing of a gecko-inspired thermoplastic micropillar array with control over the tapering angle of the pillar sidewall. A combination of deep reactive ion etching of vertical silicon pillars and subsequent maskless chemical etching produces templates with various widths and degrees of taper, which are then replicated with low-density polyethylene. As the silicon pillars on the template are chemically etched in a bath consisting of hydrofluoric acid, nitric acid, and acetic acid (HNA), the pillars are progressively thinned, then shortened. The replicated polyethylene pillar arrays exhibit a corresponding increase in friction as the stiffness is reduced with thinning and then a decrease in friction as the stiffness is again increased. The dilution of the HNA bath in water influences the tapering angle of the silicon pillars. The friction of the replicated pillars is maximized for the taper angle that maximizes the contact area at the tip which in turn is influenced by the stiffness of the tapered pillars. To provide insights on how changes in microscale geometry and contact behavior may affect friction of the pillar array, the pillars are imaged by scanning electron microscopy after friction testing, and the observed deformation behavior from shearing is related to the magnitude of the macroscale friction values. It is shown that the tapering angle critically changes the pillar compliance and the available contact area. Simple finite element modeling calculations are performed to support that the observed deformation is consistent with what is expected from a mechanical analysis. We conclude that friction can be maximized via proper pillar tapering with low stiffness that still maintains enough contact area to ensure high adhesion.

  16. Case report: AVN of the femoral head five year follow-up of the combination of ipsilateral femoral neck and sub-trochanteric fracture.

    PubMed

    Zhang, Wei; Zhu, Feng; Dong, Hanqing; Xu, Yaozeng

    2016-04-01

    To our knowledge, the type of combination of ipsilateral femoral neck and sub-trochanteric fracture is rare. And the long term follow-up is seldom been reported. A 60 year old woman suffered from a traffic accident. We gave her the intramedullary nail treatment for the combination of ipsilateral femoral neck and sub-trochanteric fracture, and the fracture indeed cured after one year and there is no clue of necrosis of the femoral head, but after 5 years, there is an evidence of necrosis of the femoral head. Combination of ipsilateral femoral neck and sub-trochanteric fracture should be kept in mind. Patients with this unusual fracture should be kept under surveillance for longer than might be thought currently to be necessary for there is a possibility of necrosis of the femoral head, even a nondisplaced femoral neck fracture.

  17. Biomechanical considerations in slipped capital femoral epiphysis and insights into prophylactic fixation.

    PubMed

    Leblanc, E; Bellemore, J M; Cheng, T; Little, D G; Birke, O

    2017-04-01

    Slipped capital femoral epiphysis (SCFE) is a deformity of the proximal femur secondary to widened and unstable physis. In stabilising the slip, gold standard treatments stop growth and involve premature physeal closure, which prevents the remodelling of the acquired deformity and creates a leg length discrepancy that may be significant in younger patients. We measured the impact of placing threaded screws across the proximal femoral physis by measuring the centre-trochanteric distance (CTD) and articulo-trochanteric distance (ATD) in participants with or without prophylactic fixation. We then compared the mechanical performance of static (stainless and titanium cannulated Synthes screws) and potentially growing implants (Synthes SCFE screw and Pega Medical Free Gliding screw) in a validated synthetic bone model. In the review of 30 non-fixed and 60 fixated hips over a mean follow-up of 1.9 years, we have noted a significant difference in pre/post CTD and ATD, as well as the change in CTD and ATD over time. In the biomechanical study, the newer implants allowing growth (Synthes SCFE screw and Pega Medical Free Gliding screw) were both shown to be at least non-inferior. The primary deformity of a SCFE in itself alters hip mechanics. Also, as confirmed in this study, there is a secondary deformity that is created by static fixation and relative trochanteric overgrowth. To help remodel mild deformities and prevent secondary trochanteric overgrowth, growing implants seem to be non-inferior to the more standard means of fixation in static testing.

  18. Temperature sensing through long period fiber gratings mechanically induced on tapered optical fibers.

    PubMed

    Pulido-Navarro, María Guadalupe; Escamilla-Ambrosio, Ponciano Jorge; Marrujo-García, Sigifredo; Álvarez-Chávez, José Alfredo; Martínez-Piñón, Fernando

    2017-07-01

    In this work the feasibility of employing two well-known techniques already used on designing optical fiber sensors is explored. The first technique employed involves monomode tapered fibers, which were fabricated using a taper machine designed, built, and implemented in our laboratory. This implementation greatly reduced the costs and fabrication time allowing us to produce the desired taper length and transmission conditions. The second technique used fiber Bragg gratings, which we decided to have mechanically induced and for that reason we devised and produced our own mechanical gratings with the help of a computer numerical control tool. This grating had to be fabricated with aluminum to withstand temperatures of up to 600°C. When light traveling through an optical fiber reaches a taper it couples into the cladding layer and comes back into the core when the taper ends. In the same manner, when the light encounters gratings in the fiber, it couples to the cladding modes, and when the gratings end, the light couples back into the core. For our experimentation, the tapering machine was programmed to fabricate single-mode tapers with 3 cm length, and the mechanically induced gratings characteristics were 5 cm length, and had a period of 500 μm and depth of the period of 300 μm. For the conducting tests, the tapered fiber is positioned in between two aluminum slabs, one grooved and the other plane. These two blocks accomplish the mechanically induced long period grating (LPG); the gratings on the grooved plaque are imprinted on the taper forming the period gratings. An optical spectrum analyzer is used to observe the changes on the transmission spectrum as the temperature varies from 20°C to 600°C. The resultant attenuation peak wavelength in the transmission spectrum shifts up to 8 nm, which is a higher shift compared to what has been reported using nontapered fibers. As the temperature increases there is no longer a shift, but there is significant power loss

  19. Plasmonic structure: fiber grating formed by gold nanorods on a tapered fiber.

    PubMed

    Trevisanutto, J O; Linhananta, A; Das, G

    2016-12-15

    The authors demonstrated the fabrication of a fiber Bragg grating-like plasmonic nanostructure on the surface of a tapered optical fiber using gold nanorods (GNRs). A multimode optical fiber with core and cladding diameters of 105 and 125 μm, respectively, was used to make a tapered fiber using a dynamic etching process. The tip diameter was ∼100  nm. Light from a laser was coupled to the untapered end of the fiber, which produced a strong evanescent field around the tapered section of the fiber. The gradient force due to the evanescent field trapped the GNRs on the surface of the tapered fiber. The authors explored possible causes of the GNR distribution. The plasmonic structure will be a good candidate for sensing based on surface enhanced Raman scattering.

  20. Mechanics of the taper integrated screwed-in (TIS) abutments used in dental implants.

    PubMed

    Bozkaya, Dinçer; Müftü, Sinan

    2005-01-01

    The tapered implant-abutment interface is becoming more popular due to the mechanical reliability of retention it provides. Consequently, understanding the mechanical properties of the tapered interface with or without a screw at the bottom has been the subject of a considerable amount of studies involving experiments and finite element (FE) analysis. This paper focuses on the tapered implant-abutment interface with a screw integrated at the bottom of the abutment. The tightening and loosening torques are the main factors in determining the reliability and the stability of the attachment. Analytical formulas are developed to predict tightening and loosening torque values by combining the equations related to the tapered interface with screw mechanics equations. This enables the identification of the effects of the parameters such as friction, geometric properties of the screw, the taper angle, and the elastic properties of the materials on the mechanics of the system. In particular, a relation between the tightening torque and the screw pretension is identified. It was shown that the loosening torque is smaller than the tightening torque for typical values of the parameters. Most of the tightening load is carried by the tapered section of the abutment, and in certain combinations of the parameters the pretension in the screw may become zero. The calculations performed to determine the loosening torque as a percentage of tightening torque resulted in the range 85-137%, depending on the values of taper angle and the friction coefficient.

  1. [Isolated true aneurysm of the deep femoral artery].

    PubMed

    Salomon du Mont, L; Holzer, T; Kazandjian, C; Saucy, F; Corpataux, J M; Rinckenbach, S; Déglise, S

    2016-07-01

    Aneurysms of the deep femoral artery, accounting for 5% of all femoral aneurysms, are uncommon. There is a serious risk of rupture. We report the case of an 83-year-old patient with a painless pulsatile mass in the right groin due to an aneurysm of the deep femoral artery. History taking revealed no cardiovascular risk factors and no other aneurysms at other localizations. The etiology remained unclear because no recent history of local trauma or puncture was found. ACT angiography was performed, revealing a true isolated aneurysm of the deep femoral artery with a diameter of 90mm, beginning 1cm after its origin. There were no signs of rupture or distal emboli. Due to unsuitable anatomy for an endovascular approach, the patient underwent open surgery, with exclusion of the aneurysm and interposition of an 8-mm Dacron graft to preserve deep femoral artery flow. Due to their localization, the diagnosis and the management of aneurysms of the deep femoral artery can be difficult. Options are surgical exclusion or an endovascular approach in the absence of symptoms or as a bridging therapy. If possible, blood flow to the distal deep femoral artery should be maintained, the decision depending also on the patency of the superficial femoral artery. In case of large size, aneurysms of the deep femoral artery should be treated without any delay. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  2. Investigation of Tapered Roller Bearing Damage Detection Using Oil Debris Analysis

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Krieder, Gary; Fichter, Thomas

    2006-01-01

    A diagnostic tool was developed for detecting fatigue damage to tapered roller bearings. Tapered roller bearings are used in helicopter transmissions and have potential for use in high bypass advanced gas turbine aircraft engines. This diagnostic tool was developed and evaluated experimentally by collecting oil debris data from failure progression tests performed by The Timken Company in their Tapered Roller Bearing Health Monitoring Test Rig. Failure progression tests were performed under simulated engine load conditions. Tests were performed on one healthy bearing and three predamaged bearings. During each test, data from an on-line, in-line, inductance type oil debris sensor was monitored and recorded for the occurrence of debris generated during failure of the bearing. The bearing was removed periodically for inspection throughout the failure progression tests. Results indicate the accumulated oil debris mass is a good predictor of damage on tapered roller bearings. The use of a fuzzy logic model to enable an easily interpreted diagnostic metric was proposed and demonstrated.

  3. Femoral neck buttressing: a radiographic and histologic analysis.

    PubMed

    Dixon, T; Benjamin, J; Lund, P; Graham, A; Krupinski, E

    2000-10-01

    To examine the incidence, radiographic and histologic findings of medial femoral neck buttressing in a consecutive group of patients undergoing total hip arthroplasty. Biomechanical parameters were evaluated on standard anteroposterior pelvic radiographs of 113 patients prior to hip replacement surgery. Demographic information on all patients was reviewed and histologic evaluation was performed on specimens obtained at the time of surgery. The incidence of medial femoral neck buttressing was found to be 50% in a consecutive series of patients undergoing total hip arthroplasty. The incidence was slightly higher in women (56% vs. 41%). Patients with buttressing had increased neck-shaft angles and smaller femoral neck diameters than were seen in patients without buttressing. Histologic evaluation demonstrated that the buttress resulted from deposition bone by the periosteum on the femoral neck in the absence of any evidence of femoral neck fracture. It would appear that femoral neck buttressing occurs in response to increased joint reactive forces seen at the hip being transmitted through the femoral neck. The increased joint reactive force can be related to the increased neck shaft angle seen in patients with buttressing.

  4. Osseointegration into a Novel Titanium Foam Implant in the Distal Femur of a Rabbit

    PubMed Central

    Willie, Bettina M.; Yang, Xu; Kelly, Natalie H.; Merkow, Justin; Gagne, Shawn; Ware, Robin; Wright, Timothy M.; Bostrom, Mathias P.G.

    2010-01-01

    A novel porous titanium foam implant has recently been developed to enhance biological fixation of orthopaedic implants to bone. The aim of this study was to examine the mechanical and histological characteristics of bone apposition into two different pore sizes of this titanium foam (565 and 464 micron mean void intercept length) and to compare these characteristics to those obtained with a fully porous conventionally sintered titanium bead implant. Cylindrical implants were studied in a rabbit distal femoral intramedullary osseointegration model at time zero and at 3, 6, and 12 weeks. The amount of bone ingrowth, amount of periprosthetic bone, and mineral apposition rate of periprosthetic bone measured did not differ among the three implant designs at 3, 6, or 12 weeks. By 12 weeks, the interface stiffness and maximum load of the beaded implant was significantly greater than either foam implant. No significant difference was found in the interface stiffness or maximum load between the two foam implant designs at 3, 6, or 12 weeks. The lower compressive modulus of the foam compared to the more dense sintered beaded implants likely contributed to the difference in failure mode. However, the foam implants have a similar compressive modulus to other clinically successful coatings, suggesting they are nonetheless clinically adequate. Additional studies are required to confirm this in weight-bearing models. Histological data suggest that these novel titanium foam implants are a promising alternative to current porous coatings and should be further investigated for clinical application in cementless joint replacement. PMID:20024964

  5. Tapered optical fiber sensor based on localized surface plasmon resonance.

    PubMed

    Lin, Hsing-Ying; Huang, Chen-Han; Cheng, Gia-Ling; Chen, Nan-Kuang; Chui, Hsiang-Chen

    2012-09-10

    A tapered fiber localized surface plasmon resonance (LSPR) sensor is demonstrated for refractive index sensing and label-free biochemical detection. The sensing strategy relies on the interrogation of the transmission intensity change due to the evanescent field absorption of immobilized gold nanoparticles on the tapered fiber surface. The refractive index resolution based on the interrogation of transmission intensity change is calculated to be 3.2×10⁻⁵ RIU. The feasibility of DNP-functionalized tapered fiber LSPR sensor in monitoring anti-DNP antibody with different concentrations spiked in buffer is examined. Results suggest that the compact sensor can perform qualitative and quantitative biochemical detection in real-time and thus has potential to be used in biomolecular sensing applications.

  6. Measurement of titanium in hip-replacement patients by inductively coupled plasma optical emission spectroscopy.

    PubMed

    Harrington, Chris F; McKibbin, Craig; Rahanu, Monika; Langton, David; Taylor, Andrew

    2017-05-01

    Background Patients with metal-on-metal hip replacements require testing for cobalt and chromium. There may also be a need to test for titanium, which is used in the construction of the femoral stem in total hip replacements. It is not possible to use quadrupole inductively coupled plasma mass spectrometry due to interferences. Methods Titanium was measured using inductively coupled plasma optical emission spectroscopy using the emission line at 336.1 nm and Y (internal standard) at 371.0 nm. Internal quality control materials were prepared for blood and serum and concentrations assigned using a sector field-inductively coupled plasma mass spectrometer. A candidate whole blood certified reference material was also evaluated. Results The method had detection and quantitation limits of 0.6 and 1.9 µg/L, respectively. The respective bias (%) and measurement uncertainty ( U) (k = 2) were 3.3% and 2.0 µg/L (serum) and - 1.0% and 1.4 µg/L (whole blood). The respective repeatability and intermediate precision (%) were 5.1% and 10.9% (serum) and 2.4% and 8.6% (whole blood). The concentration of titanium was determined in patients' samples, serum (median = 2.4 µg/L, n = 897) and whole blood (median = 2.4 µg/L, n = 189). Serum is recommended for monitoring titanium in patients, since the concentration is higher than in whole blood and the matrix less problematic. In hip fluid samples, the concentrations were much higher (mean 58.5 µg/L, median 5.1 µg/L, n = 83). Conclusions A method based on inductively coupled plasma optical emission spectroscopy was developed and validated for measuring titanium in clinical samples.

  7. The Effects of Torsional Preloading on the Torsional Resistance of Nickel-titanium Instruments.

    PubMed

    Oh, Seung-Hei; Ha, Jung-Hong; Kwak, Sang Won; Ahn, Shin Wook; Lee, WooCheol; Kim, Hyeon-Cheol

    2017-01-01

    This study evaluated the effect of torsional preloading on the torsional resistance of nickel-titanium (NiTi) endodontic instruments. WaveOne Primary (Dentsply Maillefer, Ballaigues, Switzerland) and ProTaper Universal F2 (Dentsply Maillefer) files were used. The ultimate torsional strength until fracture was determined for each instrument. In the phase 1 experiment, the ProTaper and WaveOne files were loaded to have a maximum load from 2.0 up to 2.7 or 2.8 Ncm, respectively. In the phase 2 experiment, the number of repetitions of preloading for each file was increased from 50 to 200, whereas the preloading torque was fixed at 2.4 Ncm. Using torsionally preloaded specimens from phase 1 and 2, the torsional resistances were calculated to determine the ultimate strength, distortion angle, and toughness. The results were analyzed using 1-way analysis of variance and Duncan post hoc comparison. The fracture surfaces and longitudinal aspect of 5 specimens per group were examined under a scanning electron microscope. All preloaded groups showed significantly higher ultimate strength than the unpreloaded groups (P < .05). There was no significant difference among all groups for distortion angle and toughness. Although WaveOne had no significant difference between the repetition groups for ultimate strength, fracture angle, and toughness, ProTaper had a higher distortion angle and toughness in the 50-repetition group compared with the other repetition groups (P < .05). Scanning electron microscopic examinations of the fractured surface showed typical features of torsional fracture. Torsional preloading within the ultimate values could enhance the torsional strength of NiTi instruments. The total energy until fracture was maintained constantly, regardless of the alloy type. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  8. Combination nicotine replacement therapy: strategies for initiation and tapering.

    PubMed

    Hsia, Stephanie L; Myers, Mark G; Chen, Timothy C

    2017-04-01

    Several studies and meta-analyses have demonstrated the efficacy of combination nicotine replacement therapy (NRT) for patients who wish to quit smoking. However, there is limited guidance with respect to initiation and tapering of combination NRT. We attempt to review the evidence and rationale behind combination NRT, present the dosing used in combination NRT studies, and propose a step-down approach for tapering of combination NRT with integration of behavioral strategies. Copyright © 2017. Published by Elsevier Inc.

  9. Acetabular Reconstruction With Femoral Head Autograft After Intraarticular Resection of Periacetabular Tumors is Durable at Short-term Followup.

    PubMed

    Tang, Xiaodong; Guo, Wei; Yang, Rongli; Yan, Taiqiang; Tang, Shun; Li, Dasen

    2017-12-01

    Pelvic reconstruction after periacetabular tumor resection is technically difficult and characterized by a high complication rate. Although endoprosthetic replacement can result in immediate postoperative functional recovery, biologic reconstructions with autograft may provide an enhanced prognosis in patients with long-term survival; however, little has been published regarding this approach. We therefore wished to evaluate whether whole-bulk femoral head autograft that is not contaminated by tumor can be used to reconstruct segmental bone defects after intraarticular resection of periacetabular tumors. In a pilot study, we evaluated (1) local tumor control, (2) complications, and (3) postoperative function as measured by the Musculoskeletal Tumor Society score. Between 2009 and 2015, we treated 13 patients with periacetabular malignant or aggressive benign tumors with en bloc resection, bulk femoral head autograft, and cemented THA (with or without a titanium acetabular reconstruction cup), and all were included for analysis here. During that time, the general indications for this approach were (1) patients anticipated to have a good oncologic prognosis and adequate surgical margins to allow this approach, (2) patients whose pelvic bone defects did not exceed two types (Types I + II or Types II + III as defined by Enneking and Dunham), and (3) patients whose medical insurance would not cover what otherwise might have been a pelvic tumor prosthesis. During this period, another 91 patients were treated with pelvic prosthetic replacement, which was our preferred approach. Median followup in this study was 36 months (range, 24-99 months among surviving patients; one patient died 8 months after surgery); no patients were lost to followup. Bone defects were Types II + III in five patients, and Types I + II in eight. After intraarticular resection, ipsilateral femoral head autograft combined with THA was used to reconstruct the segmental bone defect of the acetabulum

  10. Tapered Optical Fiber Sensor for Label-Free Detection of Biomolecules

    PubMed Central

    Tian, Ye; Wang, Wenhui; Wu, Nan; Zou, Xiaotian; Wang, Xingwei

    2011-01-01

    This paper presents a fast, highly sensitive and low-cost tapered optical fiber biosensor that enables the label-free detection of biomolecules. The sensor takes advantage of the interference effect between the fiber’s first two propagation modes along the taper waist region. The biomolecules bonded on the taper surface were determined by demodulating the transmission spectrum phase shift. Because of the sharp spectrum fringe signals, as well as a relatively long biomolecule testing region, the sensor displayed a fast response and was highly sensitive. To better understand the influence of various biomolecules on the sensor, a numerical simulation that varied biolayer parameters such as thickness and refractive index was performed. The results showed that the spectrum fringe shift was obvious to be measured even when the biolayer was only nanometers thick. A microchannel chip was designed and fabricated for the protection of the sensor and biotesting. Microelectromechanical systems (MEMS) fabrication techniques were used to precisely control the profile and depth of the microchannel on the silicon chip with an accuracy of 2 μm. A tapered optical fiber biosensor was fabricated and evaluated with an Immune globulin G (IgG) antibody-antigen pair. PMID:22163821

  11. Finite-Difference Time-Domain Analysis of Tapered Photonic Crystal Fiber

    NASA Astrophysics Data System (ADS)

    Ali, M. I. Md; Sanusidin, S. N.; Yusof, M. H. M.

    2018-03-01

    This paper brief about the simulation of tapered photonic crystal fiber (PCF) LMA-8 single-mode type based on correlation of scattering pattern at wavelength of 1.55 μm, analyzation of transmission spectrum at wavelength over the range of 1.0 until 2.5 μm and correlation of transmission spectrum with the refractive index change in photonic crystal holes with respect to taper size of 0.1 until 1.0 using Optiwave simulation software. The main objective is to simulate using Finite-Difference Time-Domain (FDTD) technique of tapered LMA-8 PCF and for sensing application by improving the capabilities of PCF without collapsing the crystal holes. The types of FDTD techniques used are scattering pattern and transverse transmission and principal component analysis (PCA) used as a mathematical tool to model the data obtained by MathCad software. The simulation results showed that there is no obvious correlation of scattering pattern at a wavelength of 1.55 μm, a correlation obtained between taper sizes with a transverse transmission and there is a parabolic relationship between the refractive index changes inside the crystal structure.

  12. Tapered optical fiber sensor for label-free detection of biomolecules.

    PubMed

    Tian, Ye; Wang, Wenhui; Wu, Nan; Zou, Xiaotian; Wang, Xingwei

    2011-01-01

    This paper presents a fast, highly sensitive and low-cost tapered optical fiber biosensor that enables the label-free detection of biomolecules. The sensor takes advantage of the interference effect between the fiber's first two propagation modes along the taper waist region. The biomolecules bonded on the taper surface were determined by demodulating the transmission spectrum phase shift. Because of the sharp spectrum fringe signals, as well as a relatively long biomolecule testing region, the sensor displayed a fast response and was highly sensitive. To better understand the influence of various biomolecules on the sensor, a numerical simulation that varied biolayer parameters such as thickness and refractive index was performed. The results showed that the spectrum fringe shift was obvious to be measured even when the biolayer was only nanometers thick. A microchannel chip was designed and fabricated for the protection of the sensor and biotesting. Microelectromechanical systems (MEMS) fabrication techniques were used to precisely control the profile and depth of the microchannel on the silicon chip with an accuracy of 2 μm. A tapered optical fiber biosensor was fabricated and evaluated with an Immune globulin G (IgG) antibody-antigen pair.

  13. Stability of tapered and parallel-walled dental implants: A systematic review and meta-analysis.

    PubMed

    Atieh, Momen A; Alsabeeha, Nabeel; Duncan, Warwick J

    2018-05-15

    Clinical trials have suggested that dental implants with a tapered configuration have improved stability at placement, allowing immediate placement and/or loading. The aim of this systematic review and meta-analysis was to evaluate the implant stability of tapered dental implants compared to standard parallel-walled dental implants. Applying the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) statement, randomized controlled trials (RCTs) were searched for in electronic databases and complemented by hand searching. The risk of bias was assessed using the Cochrane Collaboration's Risk of Bias tool and data were analyzed using statistical software. A total of 1199 studies were identified, of which, five trials were included with 336 dental implants in 303 participants. Overall meta-analysis showed that tapered dental implants had higher implant stability values than parallel-walled dental implants at insertion and 8 weeks but the difference was not statistically significant. Tapered dental implants had significantly less marginal bone loss compared to parallel-walled dental implants. No significant differences in implant failure rate were found between tapered and parallel-walled dental implants. There is limited evidence to demonstrate the effectiveness of tapered dental implants in achieving greater implant stability compared to parallel-walled dental implants. Superior short-term results in maintaining peri-implant marginal bone with tapered dental implants are possible. Further properly designed RCTs are required to endorse the supposed advantages of tapered dental implants in immediate loading protocol and other complex clinical scenarios. © 2018 Wiley Periodicals, Inc.

  14. Optical microscope and tapered fiber coupling apparatus for a dilution refrigerator.

    PubMed

    MacDonald, A J R; Popowich, G G; Hauer, B D; Kim, P H; Fredrick, A; Rojas, X; Doolin, P; Davis, J P

    2015-01-01

    We have developed a system for tapered fiber measurements of optomechanical resonators inside a dilution refrigerator, which is compatible with both on- and off-chip devices. Our apparatus features full three-dimensional control of the taper-resonator coupling conditions enabling critical coupling, with an overall fiber transmission efficiency of up to 70%. Notably, our design incorporates an optical microscope system consisting of a coherent bundle of 37,000 optical fibers for real-time imaging of the experiment at a resolution of ∼1 μm. We present cryogenic optical and optomechanical measurements of resonators coupled to tapered fibers at temperatures as low as 9 mK.

  15. Temperature-independent refractometer based on a tapered photonic crystal fiber interferometer

    NASA Astrophysics Data System (ADS)

    Ni, Kai; Chan, Chi Chiu; Dong, Xinyong; Poh, C. L.; Li, Tao

    2013-03-01

    A temperature-independent refractometer by using a tapered photonic crystal fiber (PCF) based Mach-Zehnder interferometer (MZI) is proposed and experimentally demonstrated. It is fabricated by sandwiching a tapered PCF of 29 mm long between two standard single mode fibers (SMFs) with the fully collapsed air holes of the PCF in the fusion splicing region. It has been found that tapering the PCF greatly enhances the sensitivity of the refractometer. A maximum sensitivity of 1529 nm/RIU (refractive index unit) is achieved within the range from 1.3355 to 1.413. The refractometer is nearly temperature-insensitive due to the ultra low temperature dependence of the used.

  16. Incidence of Avascular Necrosis of the Femoral Head After Intramedullary Nailing of Femoral Shaft Fractures

    PubMed Central

    Kim, Ji Wan; Oh, Jong-Keon; Byun, Young-Soo; Shon, Oog-Jin; Park, Jai Hyung; Oh, Hyoung Keun; Shon, Hyun Chul; Park, Ki Chul; Kim, Jung Jae; Lim, Seung-Jae

    2016-01-01

    Abstract The goal of this study was to determine the incidence of avascular necrosis of the femoral head (AVNFH) after intramedullary nailing of femoral shaft fractures and to identify risk factors for developing AVNFH. We retrospectively reviewed all patients with femoral shaft fractures treated with antegrade intramedullary nailing at 10 institutions. Among the 703 patients enrolled, 161 patients were excluded leaving 542 patients in the study. Average age was 42.1 years with average follow-up of 26.3 months. Patient characteristics and fracture patterns as well as entry point of femoral nails were identified and the incidence of AVNFH was investigated. Patients were divided into 2 groups according to open versus closed physis, open versus closed fractures, and age (<20 versus ≥20 years). Overall incidence of AVNFH was 0.2% (1 of 542): the patient was 15-year-old boy. Of 25 patients with open physis, the incidence of AVNFH was 4%, whereas none of 517 patients with closed physis developed AVNFH (P < 0.001). The incidence of AVNFH in patients aged < 20 versus ≥20 years was 1.1% (1 of 93) and 0.0% (0 of 449), respectively (P = 0.172), which meant that the incidence of AVNFH was 0% in adult with femur shaft fracture. Of 61 patients with open fractures, the incidence of AVNFH was 0%. The number of cases with entry point at the trochanteric fossa or tip of the greater trochanter (GT) was 324 and 218, respectively, and the incidence of AVNFH was 0.3% and 0.0%, respectively (P = 0.412). In patients aged ≥20 years with isolated femoral shaft fracture, there was no case of AVNFH following antegrade intramedullary nailing regardless of the entry point. Therefore, our findings suggest that the risk of AVNFH following antegrade femoral nailing is extremely low in adult patients. PMID:26844518

  17. High-sensitivity refractive index sensors based on fused tapered photonic crystal fiber

    NASA Astrophysics Data System (ADS)

    Fu, Xing-hu; Xie, Hai-yang; Yang, Chuan-qing; Qu, Yu-wei; Zhang, Shun-yang; Fu, Guang-wei; Guo, Xuan; Bi, Wei-hong

    2016-05-01

    In this paper, a novel liquid refractive index (RI) sensor based on fused tapered photonic crystal fiber (PCF) is proposed. It is fabricated by fusing and tapering a section of PCF which is spliced with two single-mode fibers (SMFs). Due to the fused biconical taper method, the sensor becomes longer and thinner, to make the change of the outside RI has more direct effects on the internal optical field of the PCF, which finally enhances the sensitivity of this sensor. Experimental results show that the transmission spectra of the sensor are red-shifted obviously with the increase of RI. The longer the tapered region of the sensor, the higher the sensitivity is. This sensor has the advantages of simple structure, easy fabrication, high performance and so on, so it has potential applications in RI measurement.

  18. Avascular necrosis of the femoral head after osteosynthesis of femoral neck fracture.

    PubMed

    Min, Byung-Woo; Kim, Sung-Jin

    2011-05-18

    The reported incidence of avascular necrosis after femoral neck fracture fixation varies widely, and there is no consensus regarding its risk factors. We evaluated the incidence of avascular necrosis of the femoral head with the use of contemporary techniques for femoral neck fracture fixation. We then sought to determine what potential risk factors influenced the development of avascular necrosis.Between 1990 and 2005, one hundred sixty-three intracapsular femoral neck fractures in 163 patients were treated with internal fixation at our level-I trauma center. All patients were monitored until conversion to total hip arthroplasty or for a minimum of 2 years postoperatively. Ten patients (10 hips) died and 7 patients (7 hips) were lost to follow-up. The remaining 146 patients (146 hips) had a mean 5.2 years of follow-up (range, 3 months to 17 years). The incidence of avascular necrosis was 25.3% (37 hips). The average time to diagnosis of avascular necrosis was 18.8 months (range, 3-47 months). Patient sex, age, interval from injury to surgery, and mechanism of injury were statistically not associated with the development of avascular necrosis. The quality of fracture reduction, adequacy of fixation, degree of displacement, and comminution of the posterior cortex were significantly associated. After we controlled for patient and radiographic characteristics, multivariate analyses indicated that the important predictors for avascular necrosis are poor reduction (odds ratio=13.889) and initial displacement of the fracture (odds ratio=4.693). Copyright 2011, SLACK Incorporated.

  19. Tapered holey fibers for spot-size and numerical-aperture conversion.

    PubMed

    Town, G E; Lizier, J T

    2001-07-15

    Adiabatically tapered holey fibers are shown to be potentially useful for guided-wave spot-size and numerical-aperture conversion. Conditions for adiabaticity and design guidelines are provided in terms of the effective-index model. We also present finite-difference time-domain calculations of downtapered holey fiber, showing that large spot-size conversion factors are obtainable with minimal loss by use of short, optimally shaped tapers.

  20. Merging taper lengths for short duration lane closure : final report, December 2009.

    DOT National Transportation Integrated Search

    2009-12-01

    The Utility Industry has requested that the Florida Department of Transportation provide for the use of merging taper lengths that are significantly shorter than the lengths computed using the taper length equations published in the MUTCD Section 6C....

  1. Bent optical fiber tapers for refractometery and biosensing

    NASA Astrophysics Data System (ADS)

    Penchev, Emil; Eftimov, Tinko; Bock, Wojtek

    2015-01-01

    We report the results of our study of the spectral shifts caused by surrounding refractive index changes (SRI) in bent fibre tapers. Fused and etched fibre tapers were fabricated using a gas burner and HF acid. Spectral shifts as high as 200 nm have been observed for SRI variations from 1.33 to 1.44 and sensitivity as high as 830 nm/r.i.u. around water RI values. We present results for refractometric measurements of cow milk of varying fat content and compare results with those obtained with conventional Abbe refractometers and high sensitivity double resonance LPGs.

  2. An in vitro assessment of the physical properties of novel Hyflex nickel-titanium rotary instruments.

    PubMed

    Peters, O A; Gluskin, A K; Weiss, R A; Han, J T

    2012-11-01

    To determine several properties including torsional and fatigue limits, as well as torque during canal preparation, of Hyflex, a rotary instrument manufactured from so-called controlled memory nickel-titanium alloy. The instruments were tested in vitro using a special torque bench that permits both stationary torque tests according to ISO3630-1 and fatigue limit determination, as well as measurement of torque (in Ncm) and apical force (in N) during canal preparation. Fatigue limit (in numbers of cycles to failure) was determined in a 90°, 5 mm radius block-and-rod assembly. Simulated canals in plastic blocks were prepared using both a manufacturer-recommended single-length technique as well as a generic crown-down approach. anova with Bonferroni post hoc procedures was used for statistical analysis. Torque at failure ranged from 0.47 to 1.38 Ncm, with significant differences between instrument sizes (P < 0.0001). Fatigue life ranged from 260 to 2565, with the shortest and longest lifespan for instruments size 20, .04 taper and size 25, .08 taper, respectively. Torque during canal preparation was significantly higher for small instruments used in the single-length technique but lower for the size 40, .04 taper, compared to a crown-down approach. No instrument fractured; 82% of the instruments used were plastically deformed; however, only 37% of these remained deformed after a sterilization cycle. Hyflex rotary instruments are bendable and flexible and have similar torsional resistance compared to instruments made of conventional NiTi. Fatigue resistance is much higher, and torque during preparation is less, compared to other rotary instruments tested previously under similar conditions. © 2012 International Endodontic Journal.

  3. Premature femoral neck physeal closure in Perthes' disease.

    PubMed

    Bowen, J R; Schreiber, F C; Foster, B K; Wein, B K

    1982-01-01

    One hundred premature femoral neck physeal closures in 430 hips with Perthes' disease have occurred in two patterns central and lateral. Abnormal physeal growth can be demonstrated early by a narrowed physeal plate with overlying avascular epiphysis and marked metaphyseal reaction below. Subsequently, a bony bridge forms between the metaphysis and epiphysis. If the physeal closure is central, the mature hip will have a short femoral neck, a relatively round femoral head, a trochanter that has overgrown the femoral head, a short leg, and a mildly deformed acetabulum. If the physeal closure is lateral, the mature hip will have a femoral head that is externally tilted as the medial neck lengthens and the lateral neck remains short, a trochanter that has overgrown the femoral head, an oval femoral head, a short leg, and a deformed acetabulum. A physeal arrest is a contraindication for a varus osteotomy because it accentuates the deformity, especially in the greater trochanter. The leg-length discrepancy may be treated by epiphysiodesis of the contralateral femur, when necessary, and the abductor muscle insufficiency may be treated by an exercise program or distal and lateral transfer of the greater trochanter.

  4. Development of a photogrammetric method of measuring tree taper outside bark

    Treesearch

    David R. Larsen

    2006-01-01

    A photogrammetric method is presented for measuring tree diameters outside bark using calibrated control ground-based digital photographs. The method was designed to rapidly collect tree taper information from subject trees for the development of tree taper equations. Software that is commercially available, but designed for a different purpose, can be readily adapted...

  5. Experimental design rules for implementing biconically tapered single mode optical fibre displacement sensors

    NASA Astrophysics Data System (ADS)

    Arregui, Francisco J.; Matias, Ignacio R.; Bariain, Candido; Lopez-Amo, Manuel

    1998-06-01

    Tapered optical fibers are used to design couplers, wavelength division multiplexers, near field scanning optical microscopy, just to mention a few. Moreover, and due to its strong transmission dependence to external medium the tapered fiber may also be used to sense distinct parameters such as temperature, humidity, PH, etc. In this work bending effects in tapers are exploited to achieved displacement sensors and to present design rules for implementing these sensors according to the desired both range and sensitivity.

  6. Taper models for commercial tree species in the northeastern United States

    Treesearch

    James A. Westfall; Charles T. Scott

    2010-01-01

    A new taper model was developed based on the switching taper model of Valentine and Gregoire; the most substantial changes were reformulation to incorporate estimated join points and modification of a switching function. Random-effects parameters were included that account for within-tree correlations and allow for customized calibration to each individual tree. The...

  7. Femoral neck-shaft angle in extra-capsular proximal femoral fracture fixation; does it make a TAD of difference?

    PubMed

    Walton, N P; Wynn-Jones, H; Ward, M S; Wimhurst, J A

    2005-11-01

    The effect of femoral neck-shaft angle and implant type on the accuracy of lag screw placement in extra-capsular proximal femoral fracture fixation was investigated. Radiographs of all extra-capsular proximal femoral fractures seen in one unit over 18 months were reviewed. Of 399 cases, 307 (237 female, 70 male) were included in the study as they had no contra-lateral proximal femoral metal work. Femoral neck-shaft angle (NSA) of the uninjured hip and magnification adjusted tip-apex distance (TAD) of femoral head lag screw were measured. Type of fixation implant was 135 degrees classic hip screw (CHS) (n=144) or 130 degrees intra-medullary hip screw (IMHS) (n=163). Mean contra-lateral NSA was 130.2 degrees (112.9--148 degrees ) and 64 patients (58 female, 6 male) had a NSA <125 degrees . Mean adjusted TAD was 18.7 mm (5.8--43.8mm) and 88.9% of cases had a TAD of less than 25 mm. TAD values were significantly greater using an IMHS if NSA was <125 degrees than if NSA was >125 degrees (p=0.028). This was not the case with the CHS. The use of the 130 degrees -IMHS in patients with a NSA <125 degrees leads to poorer lag screw placement than if NSA >125 degrees and caution is advocated when using this device in such cases.

  8. Spectrum online-tunable Mach-Zehnder interferometer based on step-like tapers and its refractive index sensing characteristics

    NASA Astrophysics Data System (ADS)

    Zhao, Yong; Chen, Mao-qing; Xia, Feng; Hu, Hai-feng

    2017-11-01

    A novel refractive index (RI) sensor based on an asymmetrical Mach-Zehnder interferometer (MZI) with two different step-like tapers is proposed. The step-like taper is fabricated by fusion splicing two half tapers with an appropriate offset. By further applying offset and discharging to the last fabricated step-like taper of MZI, influence of taper parameters on interference spectrum is investigated using only one device. This simple technique provides an on-line method to sweep parameters of step-like tapers and speeds up the optimization process of interference spectrum, meanwhile. In RI sensing experiment, the sensor has a high sensitivity of -185.79 nm/RIU (refractive index unit) in the RI range of 1.3333-1.3673.

  9. Ultraviolet, visible, and infrared laser delivery using laser-to-fiber coupling via a grazing-incidence-based hollow taper

    NASA Astrophysics Data System (ADS)

    Ilev, Ilko K.; Waynant, Ronald W.

    2001-01-01

    We present a novel all-optical-waveguide method for ultraviolet (UV), visible (VIS) and infrared (IR) laser delivery including a lens-free method of laser-to-fiber coupling using a simple uncoated glass hollow taper. Based on the grazing incidence effect, the hollow taper provides a way of direct launching, without any intermediate focusing elements, high power laser radiation into delivery fibers. Because of the mutual action of the nearly parallel laser excitation, the mode coupling process, and mode filtering effect, the hollow taper serves as a mode converter that transforms the highly multimode profile of the input laser emission into a high-quality Gaussian-shaped profile at the taper output. When the grazing incidence effect of the taper is applied to laser delivery, the maintenance of high reflectance coefficients in a wide spectral region allows to utilize the same uncoated hollow taper for laser radiation in the UV, VIS and IR ranges. Applying the experimental hollow-taper based delivery systems, we obtain high laser- to-taper and taper-to-fiber coupling efficiencies.

  10. An evaluation of .06 tapered gutta-percha cones for filling of .06 taper prepared curved root canals.

    PubMed

    Gordon, M P J; Love, R M; Chandler, N P

    2005-02-01

    To compare the area occupied by gutta-percha, sealer, or void in standardized .06 tapered prepared simulated curved canals and in mesio-buccal canals of extracted maxillary first molars filled with a single .06 gutta-percha point and sealer or lateral condensation of multiple .02 gutta-percha points and sealer. Simulated canals in resin blocks with either a 30 degrees curve and radius of 10.5 mm (n = 20) or a 58 degrees curve and 4.7 mm radius (n = 20) and curved mesio-buccal canals of extracted maxillary first molars (n = 20) were prepared using .06 ProFiles in a variable tip crown-down sequence to an apical size 35 at 0.5 mm from the canal terminus or apical foramen. Ten 30 degrees and 58 degrees curved resin canals and 10 canals in the extracted teeth group were obturated with .02 taper gutta-percha cones and AH 26 sealer using lateral condensation. The time required to obturate was recorded. The remaining canals were obturated with a single .06 taper gutta-percha cone and AH 26 sealer. Excess gutta-percha was removed from the specimens using heat and the warm mass vertically condensed. Horizontal sections were cut at 0.5, 1.5, 2.5, 4.5, 7.5 and 11.5 mm from the canal terminus or apical foramen. Colour photographs were taken using an Olympus 35 mm camera attached to a stereomicroscope set at x40 magnification, and then digitized using a flatbed scanner. The cross-sectional area of the canal contents was analysed using Adobe PhotoShop. The percentage of gutta-percha, sealer or voids to the total root canal area were derived and data analysed using unpaired Student's t-test and the Mann-Whitney U-test. In the 30 degrees curved canals the levels had between 94 and 100% of the area filled with gutta-percha with no significant difference (P > 0.05) between the lateral condensation and single cone techniques. In the 58 degrees curved canals the levels had 92-99% of the area filled with gutta-percha, with the single cone technique having significantly (P < 0.05) more

  11. Morse taper dental implants and platform switching: The new paradigm in oral implantology

    PubMed Central

    Macedo, José Paulo; Pereira, Jorge; Vahey, Brendan R.; Henriques, Bruno; Benfatti, Cesar A. M.; Magini, Ricardo S.; López-López, José; Souza, Júlio C. M.

    2016-01-01

    The aim of this study was to conduct a literature review on the potential benefits with the use of Morse taper dental implant connections associated with small diameter platform switching abutments. A Medline bibliographical search (from 1961 to 2014) was carried out. The following search items were explored: “Bone loss and platform switching,” “bone loss and implant-abutment joint,” “bone resorption and platform switching,” “bone resorption and implant-abutment joint,” “Morse taper and platform switching.” “Morse taper and implant-abutment joint,” Morse taper and bone resorption,” “crestal bone remodeling and implant-abutment joint,” “crestal bone remodeling and platform switching.” The selection criteria used for the article were: meta-analysis; randomized controlled trials; prospective cohort studies; as well as reviews written in English, Portuguese, or Spanish languages. Within the 287 studies identified, 81 relevant and recent studies were selected. Results indicated a reduced occurrence of peri-implantitis and bone loss at the abutment/implant level associated with Morse taper implants and a reduced-diameter platform switching abutment. Extrapolation of data from previous studies indicates that Morse taper connections associated with platform switching have shown less inflammation and possible bone loss with the peri-implant soft tissues. However, more long-term studies are needed to confirm these trends. PMID:27011755

  12. Simple, Flexible, Trigonometric Taper Equations

    Treesearch

    Charles E. Thomas; Bernard R. Parresol

    1991-01-01

    There have been numerous approaches to modeling stem form in recent decades. The majority have concentrated on the simpler coniferous bole form and have become increasingly complex mathematical expressions. Use of trigonometric equations provides a simple expression of taper that is flexible enough to fit both coniferous and hard-wood bole forms. As an illustration, we...

  13. Taper tables for western hemlock.

    Treesearch

    Floyd A. Johnson; Wilbur Engstrom

    1949-01-01

    In 1947 the West Coast Forestry procedures Committee recommended several mensuration projects, one of which called for the construction of taper tables for Western hemlock. In response the present tables were prepared. Basic data for these tables consist of measurements of 912 trees taken a number of years ago by members of the Pacific Northwest Forest & Range...

  14. STIR-Physics: Cold Atoms and Nanocrystals in Tapered Nanofiber and High-Q Resonator Potentials

    DTIC Science & Technology

    2016-11-02

    STIR- Physics : Cold Atoms and Nanocrystals in Tapered Nanofiber and High-Q Resonator Potentials We worked on a tapered fiber in cold atomic cloud...reviewed journals: Number of Papers published in non peer-reviewed journals: Final Report: STIR- Physics : Cold Atoms and Nanocrystals in Tapered Nanofiber...other than abstracts): Number of Peer-Reviewed Conference Proceeding publications (other than abstracts): Books Number of Manuscripts: 0.00Number of

  15. Utilization of gas-atomized titanium and titanium-aluminide powder

    NASA Astrophysics Data System (ADS)

    Moll, John H.

    2000-05-01

    A gas-atomization process has been developed producing clean, high-quality, prealloyed spherical titanium and titanium-aluminide powder. The powder is being used to manufacture hot-isostatically pressed consolidated shapes for aerospace and nonaerospace allocations. These include gamma titanium-aluminide sheet and orthorhombic titanium-aluminide wire as well as niche markets, such as x-ray drift standards and sputtering targets. The powder is also being used in specialized processes, including metal-matrix composites, laser forming, and metal-injection molding.

  16. Proximal femoral bone loss and increased rate of fracture with a proximally hydroxyapatite-coated femoral component.

    PubMed

    Radl, R; Aigner, C; Hungerford, M; Pascher, A; Windhager, R

    2000-11-01

    We performed a retrospective analysis of the clinical and radiological outcomes of total hip replacement using an uncemented femoral component proximally coated with hydroxyapatite. Of 136 patients, 118 who had undergone 124 primary total hip replacements were available for study. Their mean age was 66.5 years (19 to 90) and the mean follow-up was 5.6 years (4.25 to 7.25). At the final follow-up the mean Harris hip score was 92 (47.7 to 100). Periprosthetic femoral fractures, which occurred in seven patients (5.6%), were treated by osteosynthesis in six and conservatively in one. We had to revise five femoral components, one because of aseptic loosening, one because of septic loosening and three because of periprosthetic fracture. At the final follow-up there were definite signs of aseptic loosening in two patients. Radiologically, proximal femoral bone loss in Gruen zones I and VI was evident in 96.8% of hips, while bone hypertrophy in zones III and V was seen in 64.7%. In 24 hips (20.2%) the mean subsidence of the stem was 3.7 mm which occurred within the first 12 postoperative weeks. This indicated poor initial stability, which might have been aggravated by early weight-bearing. The high rate of failure in our study suggests that proximal femoral bone loss affects the long-term survival of the replacement.

  17. Femoral component rotation in patellofemoral joint replacement.

    PubMed

    van Jonbergen, Hans-Peter W; Westerbeek, Robin E

    2018-06-01

    Clinical outcomes in patellofemoral joint replacement may be related to femoral component rotation. Assessment of rotational alignment is however difficult as patients with isolated patellofemoral osteoarthritis often have trochlear dysplasia. The use of the medial malleolus as a landmark to guide rotation has been suggested. The purpose of our study was to evaluate this technique with regard to femoral component rotation, and to correlate rotation with clinical outcomes at one-year follow-up. Forty-one knees in 39 patients had patellofemoral joint replacement using the Zimmer Gender-Solutions patellofemoral prosthesis. Intraoperatively, we determined femoral component rotational alignment using an extramedullary rod aimed at the inferior tip of the medial malleolus. Postoperatively, we measured the angle between the femoral component and the anatomical transepicondylar axis using CT. The amount of rotation was correlated with clinical outcomes at one-year follow-up. Forty knees in 38 patients were available for one-year follow-up. Mean femoral component rotation relative to the anatomical transepicondylar axis was 1.4° external rotation (range, -3.8 to 5.7°). We found no statistically significant correlation between femoral component rotation and change from baseline KOOS subscales at one-year follow-up. Our findings show that when using the medial malleolus as a landmark to guide rotation, the femoral component of the patellofemoral prosthesis was oriented in external rotation relative to the anatomical transepicondylar axis in 80% of knees. Our study did not show a relation between the amount of external rotation and clinical outcomes. Level III. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Fusion splice between tapered inhibited coupling hypocycloid-core Kagome fiber and SMF.

    PubMed

    Zheng, Ximeng; Debord, Benoît; Vincetti, Luca; Beaudou, Benoît; Gérôme, Frédéric; Benabid, Fetah

    2016-06-27

    We report for the first time on tapering inhibited coupling (IC) hypocycloid-core shape Kagome hollow-core photonic crystal fibers whilst maintaining their delicate core-contour negative curvature with a down-ratio as large as 2.4. The transmission loss of down-tapered sections reaches a figure as low as 0.07 dB at 1550 nm. The tapered IC fibers are also spliced to standard SMF with a total insertion loss of 0.48 dB. These results show that all-fiber photonic microcells with the ultra-low loss hypocycloid core-contour Kagome fibers is now possible.

  19. Strain energy release rate analysis of delamination in a tapered laminate subjected to tension load

    NASA Technical Reports Server (NTRS)

    Salpekar, S. A.; Raju, I. S.; Obrien, T. K.

    1990-01-01

    A tapered composite laminate subjected to tension load was analyzed using the finite-element method. The glass/epoxy laminate has a (+ or - 45)sub 3 group of plies dropped in three distinct steps, each 20 ply-thicknesses apart, thus forming a taper angle of 5.71 degrees. Steep gradients of interlaminar normal and shear stress on a potential delamination interface suggest the existence of stress singularities at the points of material and geometric discontinuities created by the internal plydrops. The delamination was assumed to initiate at the thin end of the taper on a -45/+45 interface and the delamination growth was simulated in both directions, i.e., along the taper and into the thin region. The strain-energy-release rate for a delamination growing into the thin laminate consisted predominantly of mode I (opening) component. For a delamination growing along the tapered region, the strain-energy-release rate was initially all mode I, but the proportion of mode I decreased with increase in delamination size until eventually total G was all mode II. The total G for both delamination tips increased with increase in delamination size, indicating that a delamination initiating at the end of the taper will grow unstably along the taper and into the thin laminate simultaneously.

  20. The effect of component junction tapering on miniature cryocooler performance

    NASA Astrophysics Data System (ADS)

    Conrad, Ted; Pathak, Mihir G.; Ghiaasiaan, S. Mostafa; Kirkconnell, Carl

    2012-06-01

    Due to their relatively smaller volume and available cooling power, miniature cryocoolers are likely to be more sensitive to hydrodynamic losses than their full scale counterparts. Abrupt changes in diameter between cryocooler components are a possible source of such losses as flow separation and recirculation may occur at these points. Underutilization of regions of the regenerator and heat exchanger porous matrices may also occur due to jetting of fluid into these components. Eliminating such abrupt diameter changes by tapering transitions between cryocooler components may therefore improve system performance. The effects of various tapers applied at component interfaces on the performance of miniature pulse tube cryocoolers were investigated using system-level CFD models. A miniature scale pulse tube cryocooler design whose suitability for cryocooling under ideal conditions has been theoretically demonstrated was used as the basis for these models. Transitions between different combinations of open and porous regions were considered; tapers or chamfers were applied to these component junctions and the performance predictions for the resulting systems were compared to those for a model with sharp component transitions. Visualizations of the predicted flow patterns were also used to determine the effects of the applied tapers on the flow within the pulse tube.

  1. Titanium 2013

    USGS Publications Warehouse

    2014-01-01

    Titanium is the ninth most abundant element in the earth's crust and can be found in nearly all rocks and sediments. It is a lithophile element with a strong affinity for oxygen and is not found as a pure metal in nature. Titanium was first isolated as a pure metal in 1910, but it was not until 1948 that the metal was produced commercially using the Kroll process (named after its developer, William Kroll) to reduce titanium tetrachloride with magnesium to produce titanium metal.

  2. Sensitive Leptospira DNA detection using tapered optical fiber sensor.

    PubMed

    Zainuddin, Nurul H; Chee, Hui Y; Ahmad, Muhammad Z; Mahdi, Mohd A; Abu Bakar, Muhammad H; Yaacob, Mohd H

    2018-03-23

    This paper presents the development of tapered optical fiber sensor to detect a specific Leptospira bacteria DNA. The bacteria causes Leptospirosis, a deadly disease but with common early flu-like symptoms. Optical single mode fiber (SMF) of 125 μm diameter is tapered to produce 12 μm waist diameter and 15 cm length. The novel DNA-based optical fiber sensor is functionalized by incubating the tapered region with sodium hydroxide (NaOH), (3-Aminopropyl) triethoxysilane and glutaraldehyde. Probe DNA is immobilized onto the tapered region and subsequently hybridized by its complementary DNA (cDNA). The transmission spectra of the DNA-based optical fiber sensor are measured in the 1500 to 1600 nm wavelength range. It is discovered that the shift of the wavelength in the SMF sensor is linearly proportional with the increase in the cDNA concentrations from 0.1 to 1.0 nM. The sensitivity of the sensor toward DNA is measured to be 1.2862 nm/nM and able to detect as low as 0.1 fM. The sensor indicates high specificity when only minimal shift is detected for non-cDNA testing. The developed sensor is able to distinguish between actual DNA of Leptospira serovars (Canicola and Copenhageni) against Clostridium difficile (control sample) at very low (femtomolar) target concentrations. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Sealing glasses for titanium and titanium alloys

    DOEpatents

    Brow, R.K.; McCollister, H.L.; Phifer, C.C.; Day, D.E.

    1997-07-15

    Barium lanthanoborate sealing-glass compositions are provided comprising various combinations (in terms of mole-%) of boron oxide (B{sub 2}O{sub 3}), barium oxide (BaO), lanthanum oxide (La{sub 2}O{sub 3}), and at least one other oxide selected from the group consisting of aluminum oxide (Al{sub 2}O{sub 3}), calcium oxide (CaO), lithium oxide (Li{sub 2}O), sodium oxide (Na{sub 2}O), silicon dioxide (SiO{sub 2}), or titanium dioxide (TiO{sub 2}). These sealing-glass compositions are useful for forming hermetic glass-to-metal seals with titanium and titanium alloys having an improved aqueous durability and favorable sealing characteristics. Examples of the sealing-glass compositions are provided having coefficients of thermal expansion about that of titanium or titanium alloys, and with sealing temperatures less than about 900 C, and generally about 700--800 C. The barium lanthanoborate sealing-glass compositions are useful for components and devices requiring prolonged exposure to moisture or water, and for implanted biomedical devices (e.g. batteries, pacemakers, defibrillators, pumps). 1 fig.

  4. Sealing glasses for titanium and titanium alloys

    DOEpatents

    Brow, Richard K.; McCollister, Howard L.; Phifer, Carol C.; Day, Delbert E.

    1997-01-01

    Barium lanthanoborate sealing-glass compositions are provided comprising various combinations (in terms of mole-%) of boron oxide (B.sub.2 O.sub.3), barium oxide (BaO), lanthanum oxide (La.sub.2 O.sub.3), and at least one other oxide selected from the group consisting of aluminum oxide (Al.sub.2 O.sub.3), calcium oxide (CaO), lithium oxide (Li.sub.2 O), sodium oxide (Na.sub.2 O), silicon dioxide (SiO.sub.2), or titanium dioxide (TiO.sub.2). These sealing-glass compositions are useful for forming hermetic glass-to-metal seals with titanium and titanium alloys having an improved aqueous durability and favorable sealing characteristics. Examples of the sealing-glass compositions are provided having coefficients of thermal expansion about that of titanium or titanium alloys, and with sealing temperatures less than about 900.degree. C., and generally about 700.degree.-800.degree. C. The barium lanthanoborate sealing-glass compositions are useful for components and devices requiring prolonged exposure to moisture or water, and for implanted biomedical devices (e.g. batteries, pacemakers, defibrillators, pumps).

  5. Sealing glasses for titanium and titanium alloys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brow, R.K.; McCollister, H.L.; Phifer, C.C.

    1997-07-15

    Barium lanthanoborate sealing-glass compositions are provided comprising various combinations (in terms of mole-%) of boron oxide (B{sub 2}O{sub 3}), barium oxide (BaO), lanthanum oxide (La{sub 2}O{sub 3}), and at least one other oxide selected from the group consisting of aluminum oxide (Al{sub 2}O{sub 3}), calcium oxide (CaO), lithium oxide (Li{sub 2}O), sodium oxide (Na{sub 2}O), silicon dioxide (SiO{sub 2}), or titanium dioxide (TiO{sub 2}). These sealing-glass compositions are useful for forming hermetic glass-to-metal seals with titanium and titanium alloys having an improved aqueous durability and favorable sealing characteristics. Examples of the sealing-glass compositions are provided having coefficients of thermal expansionmore » about that of titanium or titanium alloys, and with sealing temperatures less than about 900 C, and generally about 700--800 C. The barium lanthanoborate sealing-glass compositions are useful for components and devices requiring prolonged exposure to moisture or water, and for implanted biomedical devices (e.g. batteries, pacemakers, defibrillators, pumps). 1 fig.« less

  6. Femoral lipectomy increases postprandial lipemia in women

    PubMed Central

    Hernandez, Teri L.; Bessesen, Daniel H.; Cox-York, Kimberly A.; Erickson, Christopher B.; Law, Christopher K.; Anderson, Molly K.; Wang, Hong; Jackman, Matthew R.

    2015-01-01

    Femoral subcutaneous adipose tissue (SAT) appears to be cardioprotective compared with abdominal SAT, possibly through better triglyceride (TG) sequestration. We hypothesized that removal of femoral SAT would increase postprandial TG through a reduction in dietary fatty acid (FA) storage. Normal-weight (means ± SD; BMI 23.9 ± 2.6 kg/m2) women (n = 29; age 45 ± 6 yr) were randomized to femoral lipectomy (LIPO) or control (CON) and followed for 1 yr. Regional adiposity was measured by DEXA and CT. A liquid meal labeled with [14C]oleic acid was used to trace the appearance of dietary FA in plasma (6-h postprandial TG), breath (24-h oxidation), and SAT (24-h [14C]TG storage). Fasting LPL activity was measured in abdominal and femoral SAT. DEXA leg fat mass was reduced after LIPO vs. CON (Δ−1.4 ± 0.7 vs. 0.1 ± 0.5 kg, P < 0.001) and remained reduced at 1 yr (−1.1 ± 1.4 vs. −0.2 ± 0.5 kg, P < 0.05), as did CT thigh subcutaneous fat area (−39.6 ± 36.6 vs. 4.7 ± 14.6 cm2, P < 0.05); DEXA trunk fat mass and CT visceral fat area were unchanged. Postprandial TG increased (5.9 ± 7.7 vs. −0.6 ± 5.3 × 103 mg/dl, P < 0.05) and femoral SAT LPL activity decreased (−21.9 ± 22.3 vs. 10.5 ± 26.5 nmol·min−1·g−1, P < 0.05) 1 yr following LIPO vs. CON. There were no group differences in 14C-labeled TG appearing in abdominal and femoral SAT or elsewhere. In conclusion, femoral fat remained reduced 1 yr following lipectomy and was accompanied by increased postprandial TG and reduced femoral SAT LPL activity. There were no changes in storage of meal-derived FA or visceral fat. Our data support a protective role for femoral adiposity on circulating TG independent of dietary FA storage and visceral adiposity. PMID:25968576

  7. Femoral lipectomy increases postprandial lipemia in women.

    PubMed

    Hernandez, Teri L; Bessesen, Daniel H; Cox-York, Kimberly A; Erickson, Christopher B; Law, Christopher K; Anderson, Molly K; Wang, Hong; Jackman, Matthew R; Van Pelt, Rachael E

    2015-07-01

    Femoral subcutaneous adipose tissue (SAT) appears to be cardioprotective compared with abdominal SAT, possibly through better triglyceride (TG) sequestration. We hypothesized that removal of femoral SAT would increase postprandial TG through a reduction in dietary fatty acid (FA) storage. Normal-weight (means ± SD; BMI 23.9 ± 2.6 kg/m(2)) women (n = 29; age 45 ± 6 yr) were randomized to femoral lipectomy (LIPO) or control (CON) and followed for 1 yr. Regional adiposity was measured by DEXA and CT. A liquid meal labeled with [(14)C]oleic acid was used to trace the appearance of dietary FA in plasma (6-h postprandial TG), breath (24-h oxidation), and SAT (24-h [(14)C]TG storage). Fasting LPL activity was measured in abdominal and femoral SAT. DEXA leg fat mass was reduced after LIPO vs. CON (Δ-1.4 ± 0.7 vs. 0.1 ± 0.5 kg, P < 0.001) and remained reduced at 1 yr (-1.1 ± 1.4 vs. -0.2 ± 0.5 kg, P < 0.05), as did CT thigh subcutaneous fat area (-39.6 ± 36.6 vs. 4.7 ± 14.6 cm(2), P < 0.05); DEXA trunk fat mass and CT visceral fat area were unchanged. Postprandial TG increased (5.9 ± 7.7 vs. -0.6 ± 5.3 × 10(3) mg/dl, P < 0.05) and femoral SAT LPL activity decreased (-21.9 ± 22.3 vs. 10.5 ± 26.5 nmol·min(-1)·g(-1), P < 0.05) 1 yr following LIPO vs. CON. There were no group differences in (14)C-labeled TG appearing in abdominal and femoral SAT or elsewhere. In conclusion, femoral fat remained reduced 1 yr following lipectomy and was accompanied by increased postprandial TG and reduced femoral SAT LPL activity. There were no changes in storage of meal-derived FA or visceral fat. Our data support a protective role for femoral adiposity on circulating TG independent of dietary FA storage and visceral adiposity. Copyright © 2015 the American Physiological Society.

  8. Effect of ripple taper on band-gap overlap in a coaxial Bragg structure operating at terahertz frequency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding Xueyong; Li Hongfan; Lv Zhensu

    Based on the mode-coupling method, numerical analysis is presented to demonstrate the influence of ripple taper on band-gap overlap in a coaxial Bragg structure operating at terahertz frequency. Results show that the interval between the band-gaps of the competing mode and the desired working mode is narrowed by use of positive-taper ripples, but is expanded if negative-taper ripples are employed, and the influence of the negative-taper ripples is obviously more advantageous than the positive-taper ripples; the band-gap overlap of modes can be efficiently separated by use of negative-taper ripples. The residual side-lobes of the frequency response in a coaxial Braggmore » structure with ripple taper also can be effectively suppressed by employing the windowing-function technique. These peculiarities provide potential advantage in constructing a coaxial Bragg cavity with high quality factor for single higher-order-mode operation of a high-power free-electron maser in the terahertz frequency range.« less

  9. Fabrication and characterization of tapered graphite/epoxy box beams

    NASA Astrophysics Data System (ADS)

    Yen, S.-C.; Gopal, P.; Dharani, L. R.

    1993-04-01

    Graphite/epoxy (T300/934) prepreg is used to fabricate tapered box beams with a taper angle of 2 deg between the top and bottom walls. The prepreg is cured on a segmented steel core using a hot-press. A screw arrangement is used to apply curing pressure in the horizontal direction, while the platens of the hot-press apply pressure in the vertical direction. The inplane bending stiffness of the beam is determined by 3-point bend test and is found to be in agreement with theory.

  10. Chirped self-similar optical pulses in tapered centrosymmetric nonlinear waveguides doped with resonant impurities

    NASA Astrophysics Data System (ADS)

    He, J. R.; Xu, S. L.; Xue, L.

    2017-11-01

    Exact chirped self-similar optical pulses propagating in tapered centrosymmetric nonlinear waveguides doped with resonant impurities are reported. The propagation behaviors of the pulses are studied by tailoring of the tapering function. Numerical simulations and stability analysis reveal that the tapering can be used to postpone the wave dispersion and the addition of a small cubic self-focusing term to the governing equation could stabilize the chirped bright pulses. An example of possible experimental protocol that may generate the pulses in realistic waveguides is given. The obtained chirped self-similar optical pulses are particularly useful in the design of amplifying or attenuating pulse compressors for chirped solitary waves in tapered centrosymmetric nonlinear waveguides doped with resonant impurities.

  11. Deformation and fracture of K3 rotary nickel-titanium endodontic instruments after clinical use.

    PubMed

    Shen, S M; Deng, M; Wang, P P; Chen, X M; Zheng, L W; Li, H L

    2016-11-01

    The aim was to evaluate the incidence and type of defects that occurred with K3 rotary nickel-titanium instruments during routine clinical use. A total of 2397 K3 (G-PACKS, SybronEndo, West Collins, Orange, CA, USA) instruments were collected from a graduate endodontic clinic over 21 months. All the instruments were limited to a maximum use of 30 canal preparations. The collected instruments were measured by a digital caliper to determine whether any fractures had occurred and then were visually inspected for deformation and fracture under a stereomicroscope. The surfaces of fractured instruments were further evaluated under a scanning electron microscope. Data were analysed using chi-square test and Kruskal-Wallis test. The incidence of instrument defect was 5.63%, consisting of 3.59% fractures and 2.05% deformations. The defect rates of 0.04 and 0.06 files were statistically higher than the other taper groups (P < 0.003) except for 0.08 files (P > 0.05). For the fractured instruments, 63.95% failed from flexural fatigue, whilst 36.05% failed from torsion. Flexural fracture was the major mode of fracture for instruments with larger taper. A routine check for instrument integrity particularly for 0.04 and 0.06 files at high magnification is recommended after each clinical use. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  12. Surface modification of titanium and titanium alloys by ion implantation.

    PubMed

    Rautray, Tapash R; Narayanan, R; Kwon, Tae-Yub; Kim, Kyo-Han

    2010-05-01

    Titanium and titanium alloys are widely used in biomedical devices and components, especially as hard tissue replacements as well as in cardiac and cardiovascular applications, because of their desirable properties, such as relatively low modulus, good fatigue strength, formability, machinability, corrosion resistance, and biocompatibility. However, titanium and its alloys cannot meet all of the clinical requirements. Therefore, to improve the biological, chemical, and mechanical properties, surface modification is often performed. In view of this, the current review casts new light on surface modification of titanium and titanium alloys by ion beam implantation. (c) 2010 Wiley Periodicals, Inc.

  13. Gentamicin-Eluting Titanium Dioxide Nanotubes Grown on the Ultrafine-Grained Titanium.

    PubMed

    Nemati, Sima Hashemi; Hadjizadeh, Afra

    2017-08-01

    Titanium (Ti)-based materials is the most appropriate choices for the applications as orthopedic and dental implants. In this regard, ultrafine-grained (UFG) titanium with an enhanced mechanical properties and surface energy has attracted more attention. Titanium dioxide (TiO 2 ) nanotubes grown on the titanium could enhance bone bonding, cellular response and are good reservoirs for loading drugs and antibacterial agents. This article investigates gentamicin loading into and release from the TiO 2 nanotubes, grown on the UFG compared to coarse-grained (CG) titanium substrate surfaces. Equal Channel Angular Pressing (ECAP) was employed to produce the UFG structure titanium. TiO 2 nanotubes were grown by the anodizing technique on both UFG and CG titanium substrate surfaces. Scanning electron microscopy (SEM) imaging confirmed TiO 2 nanotube growth on the surface. The UV-vis spectroscopy analysis results show that the amount of gentamicin load-release in the anodized UFG titanium sample is higher than that of CG one which can be explained in terms of thicker TiO 2 nanotube arrays layer formed on UFG sample. Moreover, the anodized UFG titanium samples released the drug in a longer time than CG (1 day for the UFG titanium vs. 3 h for the CG one). Regarding wettability analysis, anodized UFG titanium sample showed more enhanced hydrophilicity than CG counterpart. Therefore, the significantly smaller grain size of pure titanium provided by the ECAP technique coupled with appropriate subsequent anodization treatment not only offers a good combination of biocompatibility and adequate mechanical properties but also it provides a delayed release condition for gentamicin.

  14. Quasi-phase-matched χ(3 )-parametric interactions in sinusoidally tapered waveguides

    NASA Astrophysics Data System (ADS)

    Saleh, Mohammed F.

    2018-01-01

    In this article, I show how periodically tapered waveguides can be employed as efficient quasi-phase-matching schemes for four-wave mixing parametric processes in third-order nonlinear materials. As an example, a thorough study of enhancing third-harmonic generation in sinusoidally tapered fibers has been conducted. The quasi-phase-matching condition has been obtained for nonlinear parametric interactions in these structures using Fourier-series analysis. The dependencies of the conversion efficiency of the third harmonic on the modulation amplitude, tapering period, longitudinal-propagation direction, and pump wavelength have been studied. In comparison to uniform waveguides, the conversion efficiency has been enhanced by orders of magnitudes. I envisage that this work will have a great impact in the field of guided nonlinear optics using centrosymmetric materials.

  15. Radiation Losses Due to Tapering of a Double-Core Optical Waveguide

    NASA Technical Reports Server (NTRS)

    Lyons, Donald R.; Khet, Myat; Pencil, Eric (Technical Monitor)

    2001-01-01

    The theoretical model we designed parameterizes the power losses as a function of .the profile shape for a tapered, single mode, optical dielectric coupler. The focus of this project is to produce a working model that determines the power losses experienced by the fibers when light crosses a taper region. This phenomenon can be examined using coupled mode theory. The optical directional coupler consists of a parallel, dual-channel, waveguide with minimal spacing between the channels to permit energy exchange. Thus, power transfer is essentially a function of the taper profile. To find the fields in the fibers, the approach used was that of solving the Helmholtz equation in cylindrical coordinates involving Bessel and modified Bessel functions depending on the location.

  16. [Treatment of avascular necrosis of femoral head after femoral neck fracture with pedicled iliac bone graft].

    PubMed

    Wang, Benjie; Zhao, Dewei; Guo, Lin; Yang, Lei; Li, Zhigang; Cui, Daping; Tian, Fengde; Liu, Baoyi

    2011-05-01

    To explore the effectiveness of pedicled iliac bone graft transposition for treatment of avascular necrosis of femoral head (ANFH) after femoral neck fracture. Between June 2002 and December 2006, 22 cases (22 hips, 16 left hips and 6 right hips) of ANFH after femoral neck fracture were treated with iliac bone graft pedicled with ascending branch of the lateral femoral circumflex vessels. There were 18 males and 4 females with an age range from 28 to 48 years (mean, 37.5 years). The time from injury to internal fixation was 2-31 days, and all fractures healed within 12 months after internal fixation. The ANFH was diagnosed at 15-40 months (mean, 22 months) after internal fixation. The ANFH duration was 3-11 months (mean, 8 months). According to Association Research Circulation Osseous (ARCO) staging system, 2 hips were classified as stage IIa, 3 hips as stage IIb, 3 hips as stage IIc, 3 hips as stage IIIa, 7 hips as stage IIIb, and 4 hips as stage IIIc. The preoperative Harris hip score (HHS) was 64.10 +/- 5.95. All incisions healed by first intention and the patients had no complication of lung embolism, sciatic nerve injury, lower limb deep venous thrombosis, and numbness and pain of donor site. All patients were followed up 2.5 to 6.3 years (mean, 4.8 years). The fracture healing time was 8-12 months, and no femoral neck fracture recurred. The HHS was 90.20 +/- 5.35 at last follow-up, showing significant difference when compared with the preoperative value (t = -18.447, P = 0.000). The hip function were excellent in 11 hips, good in 10 hips, fair in 1 hip, and the excellent and good rate was 95.5%. Four hips were radiographically progressed in ARCO staging, 18 hips remained stable with a stable rate of 81.8%. Pedicled iliac bone graft transposition is an ideal option for treatment of ANFH after internal fixation of femoral neck fracture for the advantages of femoral head revascularization, sufficient cancellous bone supply, and relatively simple procedure.

  17. Orthogonal feeding techniques for tapered slot antennas

    NASA Technical Reports Server (NTRS)

    Lee, Richard Q.; Simons, Rainee N.

    1998-01-01

    For array of "brick" configuration there are electrical and mechanical advantages to feed the antenna with a feed on a substrate perpendicular to the antenna substrate. Different techniques have been proposed for exciting patch antennas using such a feed structure.Rncently, an aperture-coupled dielectric resonator antenna using a perpendicular feed substrate has been demonstrated to have very good power coupling efficiency. For a two-dimensional rectangular array with tapered slot antenna elements, a power combining network on perpendicular substrate is generally required to couple power to or from the array. In this paper, we will describe two aperture-coupled techniques for coupling microwave power from a linearly tapered slot antenna (LTSA) to a microstrip feed on a perpendicular substrate. In addition, we will present measured results for return losses and radiation patterns.

  18. Multimode interference tapered fiber refractive index sensors.

    PubMed

    Biazoli, Claudecir R; Silva, Susana; Franco, Marcos A R; Frazão, Orlando; Cordeiro, Cristiano M B

    2012-08-20

    Real-time monitoring of the fabrication process of tapering down a multimode-interference-based fiber structure is presented. The device is composed of a pure silica multimode fiber (MMF) with an initial 125 μm diameter spliced between two single-mode fibers. The process allows a thin MMF with adjustable parameters to obtain a high signal transmittance, arising from constructive interference among the guided modes at the output end of the MMF. Tapered structures with waist diameters as low as 55 μm were easily fabricated without the limitation of fragile splices or difficulty in controlling lateral fiber alignments. The sensing device is shown to be sensitive to the external environment, and a maximum sensitivity of 2946 nm/refractive index unit in the refractive index range of 1.42-1.43 was attained.

  19. Characterisation of titanium-titanium boride composites processed by powder metallurgy techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Selva Kumar, M., E-mail: sel_mcet@yahoo.co.in; Chandrasekar, P.; Chandramohan, P.

    2012-11-15

    In this work, a detailed characterisation of titanium-titanium boride composites processed by three powder metallurgy techniques, namely, hot isostatic pressing, spark plasma sintering and vacuum sintering, was conducted. Two composites with different volume percents of titanium boride reinforcement were used for the investigation. One was titanium with 20% titanium boride, and the other was titanium with 40% titanium boride (by volume). Characterisation was performed using X-ray diffraction, electron probe micro analysis - energy dispersive spectroscopy and wavelength dispersive spectroscopy, image analysis and scanning electron microscopy. The characterisation results confirm the completion of the titanium boride reaction. The results reveal themore » presence of titanium boride reinforcement in different morphologies such as needle-shaped whiskers, short agglomerated whiskers and fine plates. The paper also discusses how mechanical properties such as microhardness, elastic modulus and Poisson's ratio are influenced by the processing techniques as well as the volume fraction of the titanium boride reinforcement. - Highlights: Black-Right-Pointing-Pointer Ti-TiB composites were processed by HIP, SPS and vacuum sintering. Black-Right-Pointing-Pointer The completion of Ti-TiB{sub 2} reaction was confirmed by XRD, SEM and EPMA studies. Black-Right-Pointing-Pointer Hardness and elastic properties of Ti-TiB composites were discussed. Black-Right-Pointing-Pointer Processing techniques were compared with respect to their microstructure.« less

  20. Damage Patterns at the Head-Stem Taper Junction Helps Understand the Mechanisms of Material Loss.

    PubMed

    Hothi, Harry S; Panagiotopoulos, Andreas C; Whittaker, Robert K; Bills, Paul J; McMillan, Rebecca A; Skinner, John A; Hart, Alister J

    2017-01-01

    Material loss at the taper junction of metal-on-metal total hip arthroplasties has been implicated in their early failure. The mechanisms of material loss are not fully understood; analysis of the patterns of damage at the taper can help us better understand why material loss occurs at this junction. We mapped the patterns of material loss in a series of 155 metal-on-metal total hip arthroplasties received at our center by scanning the taper surface using a roundness-measuring machine. We examined these material loss maps to develop a 5-tier classification system based on visual differences between different patterns. We correlated these patterns to surgical, implant, and patient factors known to be important for head-stem taper damage. We found that 63 implants had "minimal damage" at the taper (material loss <1 mm 3 ), and the remaining 92 implants could be categorized by 4 distinct patterns of taper material loss. We found that (1) head diameter and (2) time to revision were key significant variables separating the groups. These material loss maps allow us to suggest different mechanisms that dominate the cause of the material loss in each pattern: (1) corrosion, (2) mechanically assisted corrosion, or (3) intraoperative damage or poor size tolerances leading to toggling of trunnion in taper. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Modular to Monoblock: Difficulties of Detaching the M(2)a-Magnum(TM) Head Are Common in Metal-on-metal Revisions.

    PubMed

    Mäntymäki, Heikki; Mäkelä, Keijo T; Vahlberg, Tero; Hirviniemi, Joni; Niinimäki, Tuukka

    2016-09-01

    Modern hip implants typically feature modular heads, which allow for easy exchange and removal from the femoral stem at the time of revision. However, owing to fretting, corrosion, or cold welding, the modular head may be difficult or impossible to separate from the underlying trunnion, especially if the implant has titanium interfaces between the head and the stem. We have repeatedly encountered difficulty removing the titanium sleeve adapter in the M(2)a-Magnum(TM) implant. Although the manufacturer warns about this complication and cases with these difficulties have been reported to the United States FDA, we believed this topic is important to study, because the frequency of difficulties in head removal is unknown and the complications related to this event have not been characterized. We asked: (1) Do revisions of M(2)a-Magnum(TM) implants differ from those of M(2)a-38(TM) implants in terms of ease of removal of the femoral head? (2) In cases where difficulty with M(2)a-Magnum(TM) head removal occurred, was the operative time, bleeding, risk of periprosthetic fracture, or joint infection increased compared with cases where the M(2)a-Magnum(TM) head was removed without difficulties? Between 2004 and 2014, we revised 296 THAs with metal-on-metal implants that involved M(2)a-Magnum(TM) (123) or M(2)a-38(TM) heads (88); of those, 84 were planned to include a femoral stem revision and insufficient data were available for three operations, so they were excluded from this analysis, leaving 124 THAs in the current retrospective study (70 THAs with M(2)a-Magnum(TM) and 54 THAs with M(2)a-38(TM) heads).The method of modular head removal, any difficulties removing the femoral head from the trunnion, operation time, and complications were recorded based on chart review. All the observed problems of detaching the head or taper adapter were among M(2)a-Magnum(TM) heads; there were no problems detaching the head in revisions of the M(2)a-38(TM) implant. In 29% (20 of 70) of

  2. Highly Sensitive Refractive Index Sensor Based on Adiabatically Tapered Microfiber Long Period Gratings

    PubMed Central

    Ji, Wen Bin; Tjin, Swee Chuan; Lin, Bo; Ng, Choong Leng

    2013-01-01

    We demonstrate a refractive index sensor based on a long period grating (LPG) inscribed in a special photosensitive microfiber with double-clad profile. The fiber is tapered gradually enough to ensure the adiabaticity of the fiber taper. In other words, the resulting insertion loss is sufficiently small. The boron and germanium co-doped inner cladding makes it suitable for inscribing gratings into its tapered form. The manner of wavelength shift for refractive indices (RIs) differs from conventional LPG, and the refractive index detection limit is 1.67 × 10−5. PMID:24141267

  3. Highly sensitive refractive index sensor based on adiabatically tapered microfiber long period gratings.

    PubMed

    Ji, Wen Bin; Tjin, Swee Chuan; Lin, Bo; Ng, Choong Leng

    2013-10-17

    We demonstrate a refractive index sensor based on a long period grating (LPG) inscribed in a special photosensitive microfiber with double-clad profile. The fiber is tapered gradually enough to ensure the adiabaticity of the fiber taper. In other words, the resulting insertion loss is sufficiently small. The boron and germanium co-doped inner cladding makes it suitable for inscribing gratings into its tapered form. The manner of wavelength shift for refractive indices (RIs) differs from conventional LPG, and the refractive index detection limit is 1.67 × 10⁻⁵.

  4. The influence of patient factors on femoral rotation after total hip arthroplasty.

    PubMed

    Tezuka, Taro; Inaba, Yutaka; Kobayashi, Naomi; Choe, Hyonmin; Higashihira, Syota; Saito, Tomoyuki

    2018-06-09

    A postoperative change in femoral rotation following total hip arthroplasty (THA) might be the cause of dislocation due to the change in combined anteversion. However, very few studies have evaluated the femoral rotation angle following THA, or the factors that influence femoral rotation. We aimed to evaluate changes in femoral rotation after THA, and to investigate preoperative patient factors that influence femoral rotation after THA. This study involved 211 hips treated with primary THA. We used computed tomography to measure the femoral rotation angle before and one week after THA. In addition, multiple regression analysis was performed to evaluate preoperative patient factors that could influence femoral rotation after THA. The femoral rotation angle was 0.2 ± 14° externally before surgery and 4.4 ± 12° internally after surgery (p < 0.001). Multiple regression analysis revealed that sex (β = 0.19; p = 0.003), age (β = 0.15; p = 0.017), preoperative anatomical femoral anteversion (β = - 0.25; p = 0.002), and preoperative femoral rotation angle (β = 0.36; p < 0.001) were significantly associated with the postoperative femoral rotation angle. The final model of the regression formula was described by the following equation: [postoperative femoral rotation angle = 5.41 × sex (female: 0, male: 1) + 0.15 × age - 0.22 × preoperative anatomical femoral anteversion + 0.33 × preoperative femoral rotation angle - 10.1]. The current study showed the mean internal change of 4.6° in the femoral rotation angle one week after THA. Sex, age, preoperative anatomical femoral anteversion and preoperative femoral rotation were associated with postoperative femoral rotation. The patients who were male, older, and who exhibited lesser preoperative anatomical femoral anteversion or greater preoperative femoral rotation angles, tended to demonstrate an externally rotated femur after THA. Conversely

  5. Femoral Reconstruction Using External Fixation

    PubMed Central

    Palatnik, Yevgeniy; Rozbruch, S. Robert

    2011-01-01

    Background. The use of an external fixator for the purpose of distraction osteogenesis has been applied to a wide range of orthopedic problems caused by such diverse etiologies as congenital disease, metabolic conditions, infections, traumatic injuries, and congenital short stature. The purpose of this study was to analyze our experience of utilizing this method in patients undergoing a variety of orthopedic procedures of the femur. Methods. We retrospectively reviewed our experience of using external fixation for femoral reconstruction. Three subgroups were defined based on the primary reconstruction goal lengthening, deformity correction, and repair of nonunion/bone defect. Factors such as leg length discrepancy (LLD), limb alignment, and external fixation time and complications were evaluated for the entire group and the 3 subgroups. Results. There was substantial improvement in the overall LLD, femoral length discrepancy, and limb alignment as measured by mechanical axis deviation (MAD) and lateral distal femoral angle (LDFA) for the entire group as well as the subgroups. Conclusions. The Ilizarov external fixator allows for decreased surgical exposure and preservation of blood supply to bone, avoidance of bone grafting and internal fixation, and simultaneous lengthening and deformity correction, making it a very useful technique for femoral reconstruction. PMID:21991425

  6. Functional overreaching: the key to peak performance during the taper?

    PubMed

    Aubry, Anaël; Hausswirth, Christophe; Louis, Julien; Coutts, Aaron J; LE Meur, Yann

    2014-09-01

    The purpose of this study is to examine whether performance supercompensation during taper is maximized in endurance athletes after experiencing overreaching during an overload training (OT) period. Thirty-three trained male triathletes were assigned to either OT (n = 23) or normal training groups (n = 10, CTL) during 8 wk. Cycling performance and maximal oxygen uptake (V˙O2max) were measured after 1 wk of moderate training, a 3-wk period of OT, and then each week during 4-wk taper. Eleven of the 23 subjects from the OT group were diagnosed as functionally overreached (F-OR) after the overload period (decreased performance with concomitant high perceived fatigue), whereas the 12 other subjects were only acutely fatigued (AF) (no decrease in performance). According to qualitative statistical analysis, the AF group demonstrated a small to large greater peak performance supercompensation than the F-OR group (2.6% ± 1.1%) and the CTL group (2.6% ± 1.6%). V˙O2max increased significantly from baseline at peak performance only in the CTL and AF groups. Of the peak performances, 60%, 83%, and 73% occurred within the two first weeks of taper in CTL, AF, and OR, respectively. Ten cases of infection were reported during the study with higher prevalence in F-OR (70%) than that in AF (20%) and CTL (10%). This study showed that 1) greater gains in performance and V˙O2max can be achieved when higher training load is prescribed before the taper but not in the presence of F-OR; 2) peak performance is not delayed during taper when heavy training loads are completed immediately prior; and 3) F-OR provides higher risk for training maladaptation, including increased infection risks.

  7. A Survey on Nickel Titanium Rotary Instruments and their Usage Techniques by Endodontists in India

    PubMed Central

    Saraf, Prahlad A; Penukonda, Raghavendra; Vanaki, Sneha S; Kamatagi, Laxmikant

    2017-01-01

    Introduction The preference and usage of nickel titanium rotary instruments varies from individual to individual based on their technique, experience with the rotary systems and the clinical situation. Very limited information is available to explain the adoption of changing concepts with respect to nickel titanium rotary instruments pertaining to the endodontists in India. Aim The aim of this study was to conduct a questionnaire survey to acquire the knowledge concerning different NiTi rotary instruments and their usage techniques by endodontists in India. Materials and Methods A Survey questionnaire was designed which consisted of 32 questions regarding designation, demographics, experience with rotary instruments, usage of different file systems, usage techniques, frequency of reuse, occurrence of file fracture, reasons and their management was distributed by hand in the national postgraduate convention and also disseminated via electronic medium to 400 and 600 endodontists respectively. Information was collected from each individual to gain insight into the experiences and beliefs of endodontists concerning the new endodontic technology of rotary NiTi instrumentation based on their clinical experience with the rotary systems. The questions were designed to ascertain the problems, patterns of use and to identify areas of perceived or potential concern regarding the rotary instruments and the data acquired was statistically evaluated using Fisher’s-exact test and the Chi-Square test. Results Overall 63.8% (638) endodontists responded. ProTaper was one of the most commonly used file system followed by M two and ProTaper Next. There was a significant co relation between the years of experience and the file re use frequency, preparation technique, file separation, management of file separation. Conclusion A large number of Endodontists prefer to reuse the rotary NiTi instruments. As there was an increase in the experience, the incidence of file separation reduced

  8. Risk Stratification for Avascular Necrosis of the Femoral Head After Internal Fixation of Femoral Neck Fractures by Post-Operative Bone SPECT/CT.

    PubMed

    Han, Sangwon; Oh, Minyoung; Yoon, Seokho; Kim, Jinsoo; Kim, Ji-Wan; Chang, Jae-Suk; Ryu, Jin-Sook

    2017-03-01

    Avascular necrosis (AVN) of the femoral head is a major complication after internal fixation of a femoral neck fracture and determines the functional prognosis. We investigated postoperative bone single-photon emission computed tomography/computed tomography (SPECT/CT) for assessing the risk of femoral head AVN. We retrospectively reviewed 53 consecutive patients who underwent bone SPECT/CT within 2 weeks of internal fixation of a femoral neck fracture and follow-up serial hip radiographs over at least 12 months. Nine patients developed femoral head AVN. In 15 patients who showed normal uptake on immediate postoperative SPECT/CT, no AVN occurred, whereas 9 of 38 patients who showed cold defects of the femoral head later developed AVN. The negative predictive value of immediate postoperative SPECT/CT for AVN was 100 %, whereas the positive predictive value was 24 %. Among 38 patients with cold defects, 1 developed AVN 3 months postoperatively. A follow-up bone SPECT/CT was performed in the other 37 patients at 2-10 months postoperatively. The follow-up bone SPECT/CT revealed completely normalized femoral head uptake in 27, partially normalized uptake in 8, and persistent cold defects in 2 patients. AVN developed in 3.7 % (1/27), 62.5 % (5/8), and 100 % (2/2) of each group, respectively. According to the time point of imaging, radiotracer uptake patterns of the femoral head on postoperative bone SPECT/CT indicate the risk of AVN after internal fixation of femoral neck fractures differently. Postoperative bone SPECT/CT may help orthopedic surgeons determine the appropriate follow-up of these patients.

  9. Normal neurodynamic responses of the femoral slump test.

    PubMed

    Lai, Weng-Hang; Shih, Yi-Fen; Lin, Pei-Ling; Chen, Wen-Yin; Ma, Hsiao-Li

    2012-04-01

    Femoral slump test is a neurodynamic testing, which could be used to assess the mechanosensitivity of the femoral component of the nervous system. Although Trainor and Pinnington reported the diagnosis accuracy of the femoral slump test, the neurodynamic responses of the femoral slump test have never been studied. The purposes of this study were to evaluate whether maneuvers that changed the nerve tension altered the responses of the femoral slump test and if these responses were influenced by gender and leg dominance; and to identify the correlations between flexibility and measured hip extension angle. Thirty-two asymptomatic subjects (16 males, 16 females) were recruited. The femoral slump test was performed in trunk slump and neutral positions, and cervical extension was used as the structure differential technique. Hip extension angle and visual analog scale (VAS) of thigh pain was measured during the test. Our results showed the decrease of nerve tension significantly increased hip extension ROM (P < 0.001) and lowered pain intensity (P < 0.001). The hip extension ROM was similar between genders but smaller for the dominant leg, as compared to the non-dominant side (P < 0.05); and the hip ROM did not correlate with any of the flexibility indices (P > 0.05). These findings indicated that femoral slump test resulted in normal neurodynamic responses in individuals free of lower extremity problems, and these responses were independent of the influence of muscle flexibility or gender. Future research should emphasize the use of femoral slump test in patient groups such as low back and anterior knee pain. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Fretting-corrosion at the modular tapers interface: Inspection of standard ASTM F1875-98.

    PubMed

    Bingley, Rachel; Martin, Alan; Manfredi, Olivia; Nejadhamzeeigilani, Mahdiyar; Oladokun, Abimbola; Beadling, Andrew Robert; Siddiqui, Sohail; Anderson, James; Thompson, Jonathan; Neville, Anne; Bryant, Michael

    2018-05-01

    Interest in the degradation mechanisms at the modular tapers interfaces has been renewed due to increased reported cases of adverse reactions to metal debris and the appearance of wear and corrosion at the modular tapers interfaces at revision. Over the past two decades, a lot of research has been expended to understand the degradation mechanisms, with two primary implant loading procedures and orientations used consistently across the literature. ASTM F1875-98 is often used as a guide to understand and benchmark the tribocorrosion processes occurring within the modular tapers interface. This article presents a comparison of the two methods outlined in ASTM F1875-98 as well as a critique of the standard considering the current paradigm in pre-clinical assessment of modular tapers.

  11. Dentine chips produced by nickel-titanium rotary instruments.

    PubMed

    Guppy, D R; Curtis, R V; Ford, T R

    2000-12-01

    This study aimed to compare the cross-sectional shape of two nickel-titanium rotary instruments, namely ProFile and Quantec files, both ISO 25, 0.06 taper, and sought to relate this to the chips produced by cutting dentine. A limited comparison was made with stainless steel engine reamers. First, five files of each type were sectioned transversely at 12 mm, 8 mm and 4 mm from the tip and examined by scanning electron microscopy. The cutting angles were assessed by a direct measurement technique which allowed for the inclination of a cutting edge to the root canal. Second, eight samples of cutting debris were collected from instrumentation by each type of nickel-titanium file and four samples from the engine reamers. The major and minor axis, area and roundness of the dentine chips in each sample were measured using computerized particle analysis. The results demonstrated that all files had a negative cutting angle which varied at the different levels (ProFiles range 69.4 degrees to 58.4 degrees and Quantec range 74.8 degrees to 56.8 degrees). The consistency within files of the same type was good as demonstrated by low standard deviations, except for Quantec files at the 4 mm level where higher standard deviations of 4.1 degrees and 5.5 degrees for the two blades were found. The chip analysis showed significant differences between chips produced by ProFile and Quantec files (P < 0.05). The latter were larger and rounder. The chips from the ProFile and the engine reamer chips were similar in dimension (P > 0.05). No simple relationship existed between file geometry and the dentine chips produced during instrumentation.

  12. Characterized Brillouin scattering in silica optical fiber tapers based on Brillouin optical correlation domain analysis.

    PubMed

    Zou, Weiwen; Jiang, Wenning; Chen, Jianping

    2013-03-11

    This paper demonstrates stimulated Brillouin scattering (SBS) characterization in silica optical fiber tapers drawn from commercial single mode optical fibers by hydrogen flame. They have different waist diameters downscaled from 5 μm to 42 μm. The fully-distributed SBS measurement along the fiber tapers is implemented by Brillouin optical correlation domain analysis technique with millimeter spatial resolution. It is found that the Brillouin frequency shift (BFS) in the waist of all fiber tapers is approximately the same (i.e., ~11.17 GHz at 1550 nm). However, the BFS is gradually reduced and the Brillouin gain decreases from the waist to the untapered zone in each fiber taper.

  13. The effect of preparation taper on the retention of cemented cast crowns under lateral fatigue loading.

    PubMed

    Cameron, Stephen M; Morris, W Jack; Keesee, Stephen M; Barsky, Todd B; Parker, M Harry

    2006-06-01

    Clinicians have used resistance form as a basis for determining guidelines for preparation design to ensure clinical success of cemented cast restorations. Disagreement on whether clinical success follows the on-off or linear nature of resistance form continues. The purpose of this study was to evaluate the number of cycles required to dislodge a cemented complete crown casting under a cyclic lateral load as a function of taper and to compare this relationship for the resistive and nonresistive ranges of taper. Three dies were milled from stainless steel at each of the following tapers: 4, 8, 12, 16, 20, 24, 28, and 32 degrees. A gold-palladium metal-ceramic alloy crown was fabricated for each die, cemented, and subjected to lateral cyclic loading until failure or 1,000,000 cycles. The limiting taper for the dies with their given height and base was 26.6 degrees. Dies with taper less than 26.6 degrees had resistance form, whereas dies with taper larger than 26.6 degrees did not. A linear regression (alpha=.05) was used to evaluate the relation of cycles at dislodgement to taper. The average number of cycles to crown dislodgement or completion for each taper (SD), in units of 10,000, was as follows: 4 degrees, 100 (0); 8 degrees, 100 (0); 12 degrees, 93.54 (16.56); 16 degrees, 61.33 (38.47); 20 degrees, 25.73 (34.67); 24 degrees, 4.33 (7.36); 28 degrees, 0.06 (0.08); and 32 degrees, 0.05 (0.09). The crowns in the resistive area less than 26.6 degrees that demonstrated failure showed a linear regression with a correlation coefficient of -0.995 between the average number of cycles to dislodge the crown and the taper. The slope was significantly different from zero (P=.0048), with a value of -7.58 and a standard error of 0.53. The number of cycles required to cause crown dislodgement was linear after 12 degrees in the resistive area and nearly zero for preparations in the nonresistive area. The limiting taper concept closely predicted the transition point where the

  14. Temperature-independent curvature sensor based on tapered photonic crystal fiber interferometer

    NASA Astrophysics Data System (ADS)

    Ni, Kai; Li, Tao; Hu, Limin; Qian, Wenwen; Zhang, Quanyao; Jin, Shangzhong

    2012-11-01

    A temperature-independent highly-sensitive curvature sensor by using a tapered-photonic crystal fiber (PCF)-based Mach-Zehnder interferometer (MZI) is proposed and experimentally demonstrated. It is fabricated by sandwiching a tapered-PCF between two standard single mode fibers (SMFs) with the air holes of the PCF in the fusion splicing region being fully collapsed. The tapering of PCF is found to enhance the sensitivity significantly. Large curvature sensitivities of 2.81 dB/m-1 and 8.35 dB/m-1 are achieved in the measurement ranges of 0.36-0.87 m-1 and 0.87-1.34 m-1, respectively, with the resolution of 0.0012 m-1 being guaranteed. The proposed sensor also shows negligible temperature sensitivity less than 0.006 dB/°C.

  15. Titanium hermetic seals

    DOEpatents

    Brow, Richard K.; Watkins, Randall D.

    1995-07-04

    Titanium is prenitrided by being heated in a nitrogen environment under conditions which give rise to the formation of a titanium-nitride surface layer on the titanium. Titanium thus prenitrided may be used in electrical components which are hermetically sealed using silicate glasses and standard glass sealing techniques. According to the method of the invention, alkali volatilization and formation of deleterious interfacial silicide are inhibited.

  16. Titanium hermetic seals

    DOEpatents

    Brow, Richard K.; Watkins, Randall D.

    1995-01-01

    Titanium is prenitrided by being heated in a nitrogen environment under conditions which give rise to the formation of a titanium-nitride surface layer on the titanium. Titanium thus prenitrided may be used in electrical components which are hermetically sealed using silicate glasses and standard glass sealing techniques. According to the method of the invention, alkali volatilization and formation of deleterious interfacial silicide are inhibited.

  17. Improved power and efficiency for tapered lasers with optimized photonic crystal structures

    NASA Astrophysics Data System (ADS)

    Ma, Xiaolong; Qu, Hongwei; Zhao, Shaoyu; Zhou, Xuyan; Lin, Yuzhe; Zheng, Wanhua

    2017-10-01

    High power and high beam quality laser sources are required in numerous applications such as nonlinear frequency conversion, optical pumping of solid-state and fiber lasers, material processing and others. Tapered lasers can provide a high output power while keeping a high beam quality. However, the conventional tapered lasers suffer from a large vertical beam divergence. We have demonstrated 2-mm long tapered lasers with photonic crystal structures. A high beam quality and a narrow vertical divergence are achieved. In this paper, we optimized the photonic crystal structure and fabricated a 4-mm long tapered laser to further increase the output power and the wall-plug efficiency. Compared with our precious wafer, the optimized structure has a lower doping level to reduce the internal loss. The period of the photonic crystal structure and the thickness of the upper cladding are also reduced. The device has a 1-mm long ridge-waveguide section and a 3-mm long tapered section. The taper angle is 4°. An output power of 7.3 W is achieved with a peak wall-plug efficiency of 46% in continuous-wave mode. The threshold current is around 500 mA and the slope efficiency is 0.93 W/A. In pulsed mode, the output power is 15.6 W and the maximum wall-plug efficiency is 48.1%. The far-field divergence with full width at half maximum is 6.3° for the lateral direction at 3 A. The vertical far-field beam divergence is around 11° at different injection levels. High beam qualities are demonstrated by beam quality factor M2 of 1.52 for the lateral direction and 1.54 for the vertical direction.

  18. Salivary hormones, IgA, and performance during intense training and tapering in judo athletes.

    PubMed

    Papacosta, Elena; Gleeson, Michael; Nassis, George P

    2013-09-01

    The aims of this study were to identify the time course of change of salivary testosterone (sT), cortisol (sC), and IgA (SIgA); mood state; and performance capacity during a 2-week taper in judo athletes and to examine the diurnal variation in these salivary markers. Eleven male judo athletes completed 5 weeks of training: 1 week of normal training (NORM), 2 weeks of intensified training (INT), and 2 weeks of exponential tapering (TAPER). Once per week subjects completed vertical and horizontal countermovement jump tests, a grip strength test, a Special Judo Fitness Test, a multistage aerobic fitness test, a 3 × 300-m run test, and anthropometric measurement. Subjects also completed questionnaires to assess mood state and muscle soreness. Two daily saliva samples (at 0700 and 1900) were collected at the end of each week during NORM and INT and every day during TAPER. Increased morning sT, decreased evening sC, lower muscle soreness, and enhanced mood state (p < 0.05) were evident by the early phases of TAPER. A significant 7.0% improvement in 3 × 300-m performance time, a 6.9% improvement in the vertical jump (p < 0.05), and increased morning and evening SIgA secretion rate (p < 0.01) were observed during the middle-late phases of TAPER. The higher values of salivary variables were observed in the morning. This study indicates that salivary hormones display diurnal variation. Furthermore, changes in hormonal responses, mood state, and muscle soreness precede enhancements in performance and mucosal immunity, suggesting that judo athletes taper for at least a week before competition.

  19. Efficiency considerations for the purely tapered interference fit (TIF) abutments used in dental implants.

    PubMed

    Bozkaya, Dinçer; Müftü, Sinan

    2004-08-01

    A tapered interference fit provides a mechanically reliable retention mechanism for the implant-abutment interface in a dental implant. Understanding the mechanical properties of the tapered interface with or without a screw at the bottom has been the subject of a considerable amount of studies involving experiments and finite element (FE) analysis. In this paper, approximate closed-form formulas are developed to analyze the mechanics of a tapered interference fit. In particular, the insertion force, the efficiency, defined as the ratio of the pull-out force to insertion force, and the critical insertion depth, which causes the onset of plastic deformation, are analyzed. It is shown that the insertion force is a function of the taper angle, the contact length, the inner and outer radii of the implant, the static and the kinetic coefficients of friction, and the elastic modulii of the implant/abutment materials. The efficiency of the tapered interference fit, which is defined as the ratio of the pull-out force to insertion force, is found to be greater than one, for taper angles that are less than 6 deg when the friction coefficient is 0.3. A safe range of insertion forces has been shown to exist. The lower end of this range depends on the maximum pull-out force that may occur due to occlusion in the multiple tooth restorations and the efficiency of the system; and the upper end of this range depends on the plastic deformation of the abutment and the implant due to interference fit. It has been shown that using a small taper angle and a long contact length widens the safe range of insertion forces.

  20. The failures of root canal preparation with hand ProTaper.

    PubMed

    Bătăiosu, Marilena; Diaconu, Oana; Moraru, Iren; Dăguci, C; Tuculină, Mihaela; Dăguci, Luminiţa; Gheorghiţă, Lelia

    2012-07-01

    The failures of root canal preparation are due to some anatomical deviation (canal in "C" or "S") and some technique errors. The technique errors are usually present in canal root cleansing and shaping stage and are the result of endodontic treatment objectives deviation. Our study was made on technique errors while preparing the canal roots with hand ProTaper. Our study was made "in vitro" on 84 extracted teeth (molars, premolars, incisors and canines). The canal root of these teeth were cleansed and shaped with hand ProTaper by crown-down technique and canal irrigation with NaOCl(2,5%). The dental preparation control was made by X-ray. During canal root preparation some failures were observed like: canal root overinstrumentation, zipping and stripping phenomenon, discarded and/or fractured instruments. Hand ProTaper represents a revolutionary progress of endodontic treatment, but a deviation from accepted rules of canal root instrumentation can lead to failures of endodontic treatment.

  1. The failures of root canal preparation with hand ProTaper

    PubMed Central

    Bătăiosu, Marilena; Diaconu, Oana; Moraru, Iren; Dăguci, C.; Ţuculină, Mihaela; Dăguci, Luminiţa; Gheorghiţă, Lelia

    2012-01-01

    The failures of root canal preparation are due to some anatomical deviation (canal in “C” or “S”) and some technique errors. The technique errors are usually present in canal root cleansing and shaping stage and are the result of endodontic treatment objectives deviation. Objectives: Our study was made on technique errors while preparing the canal roots with hand ProTaper. Methodology: Our study was made “in vitro” on 84 extracted teeth (molars, premolars, incisors and canines). The canal root of these teeth were cleansed and shaped with hand ProTaper by crown-down technique and canal irrigation with NaOCl(2,5%). The dental preparation control was made by X-ray. Results: During canal root preparation some failures were observed like: canal root overinstrumentation, zipping and stripping phenomenon, discarded and/or fractured instruments. Conclusions: Hand ProTaper represents a revolutionary progress of endodontic treatment, but a deviation from accepted rules of canal root instrumentation can lead to failures of endodontic treatment. PMID:24778848

  2. Magnetic field tunability of optical microfiber taper integrated with ferrofluid.

    PubMed

    Miao, Yinping; Wu, Jixuan; Lin, Wei; Zhang, Kailiang; Yuan, Yujie; Song, Binbin; Zhang, Hao; Liu, Bo; Yao, Jianquan

    2013-12-02

    Optical microfiber taper has unique propagation properties, which provides versatile waveguide structure to design the tunable photonic devices. In this paper, the S-tapered microfiber is fabricated by using simple fusion spicing. The spectral characteristics of microfiber taper integrated with ferrofluid under different magnetic-field intensities have been theoretically analyzed and experimentally demonstrated. The spectrum are both found to become highly magnetic-field-dependent. The results indicate the transmission and wavelength of the dips are adjustable by changing magnetic field intensity. The response of this device to the magnetic field intensity exhibits a Langvin function. Moreover, there is a linear relationship between the transmission loss and magnetic field intensity for a magnetic field intensity range of 25 to 200Oe, and the sensitivities as high as 0.13056dB/Oe and 0.056nm/Oe have been achieved, respectively. This suggests a potential application of this device as a tunable all-in-fiber photonic device, such as magneto-optic modulator, filter, and sensing element.

  3. Principles and performance of tapered fiber lasers: from uniform to flared geometry.

    PubMed

    Kerttula, Juho; Filippov, Valery; Chamorovskii, Yuri; Ustimchik, Vasily; Golant, Konstantin; Okhotnikov, Oleg G

    2012-10-10

    We have studied the recently demonstrated concept of fiber lasers based on active tapered double-clad fiber (T-DCF) in copropagating and counterpropagating configurations, both theoretically and experimentally, and compared the performance to fiber lasers based on conventional cylindrical fibers in end-pumped configurations. Specific properties of T-DCFs were considered theoretically using a rate-equation model developed for tapered fibers, and a detailed comparative study was carried out experimentally. Furthermore, we have studied mode coupling effects in long adiabatic tapers due to coiling and local bending. The results allow us to conclude that, with proper fiber design, the T-DCF technology offers a high-potential alternative for bright, cost-effective fiber devices.

  4. Transverse Vibration of Tapered Single-Walled Carbon Nanotubes Embedded in Viscoelastic Medium

    NASA Astrophysics Data System (ADS)

    Lei, Y. J.; Zhang, D. P.; Shen, Z. B.

    2017-12-01

    Based on the nonlocal theory, Euler-Bernoulli beam theory and Kelvin viscoelastic foundation model, free transverse vibration is studied for a tapered viscoelastic single-walled carbon nanotube (visco-SWCNT) embedded in a viscoelastic medium. Firstly, the governing equations for vibration analysis are established. And then, we derive the natural frequencies in closed form for SWCNTs with arbitrary boundary conditions by applying transfer function method and perturbation method. Numerical results are also presented to discuss the effects of nonlocal parameter, relaxation time and taper parameter of SWCNTs, and material property parameters of the medium. This study demonstrates that the proposed model is available for vibration analysis of the tapered SWCNTs-viscoelastic medium coupling system.

  5. Tunable optofluidic microring laser based on a tapered hollow core microstructured optical fiber.

    PubMed

    Li, Zhi-Li; Zhou, Wen-Yuan; Luo, Ming-Ming; Liu, Yan-Ge; Tian, Jian-Guo

    2015-04-20

    A tunable optofluidic microring dye laser within a tapered hollow core microstructured optical fiber was demonstrated. The fiber core was filled with a microfluidic gain medium plug and axially pumped by a nanosecond pulse laser at 532 nm. Strong radial emission and low-threshold lasing (16 nJ/pulse) were achieved. Lasing was achieved around the surface of the microfluidic plug. Laser emission was tuned by changing the liquid surface location along the tapered fiber. The possibility of developing a tunable laser within the tapered simplified hollow core microstructured optical fiber presents opportunities for developing liquid surface position sensors and biomedical analysis.

  6. Femoral tunnel placement in single-bundle anterior cruciate ligament reconstruction: a cadaveric study relating transtibial lateralized femoral tunnel position to the anteromedial and posterolateral bundle femoral origins of the anterior cruciate ligament.

    PubMed

    Rue, John-Paul H; Ghodadra, Neil; Bach, Bernard R

    2008-01-01

    There is controversy regarding the necessity of reconstructing both the posterolateral and anteromedial bundles of the anterior cruciate ligament. A laterally oriented transtibial drilled femoral tunnel replaces portions of the femoral footprints of the anteromedial and posterolateral bundles of the anterior cruciate ligament. Descriptive laboratory study. Footprints of the anteromedial and posterolateral bundles of the anterior cruciate ligament were preserved on 7 matched pairs (5 female, 2 male) of fresh-frozen human cadaveric femurs (14 femurs total). Each femur was anatomically oriented and secured in a custom size-appropriate, side-matched replica tibia model to simulate transtibial retrograde drilling of a 10-mm femoral tunnel in each specimen. The relationship of the tunnel relative to footprints of both bundles of the anterior cruciate ligament was recorded using a Microscribe MX digitizer. The angle of the femoral tunnel relative to the vertical 12-o'clock position was recorded for all 14 specimens; only 10 specimens were used for footprint measurements. On average, the 10-mm femoral tunnel overlapped 50% of the anteromedial bundle (range, 2%-83%) and 51% of the posterolateral bundle (range, 16%-97%). The footprint of the anteromedial bundle occupied 32% (range, 3%-49%) of the area of the tunnel; the footprint of the posterolateral bundle contributed 26% (range, 7%-41%). The remainder of the area of the 10-mm tunnel did not overlap with the anterior cruciate ligament footprint. The mean absolute angle of the femoral tunnel as measured directly on the specimen was 48 degrees (range, 42 degrees-53 degrees) from vertical, corresponding to approximately a 10:30 clock face position on a right knee. Anterior cruciate ligament reconstruction using a laterally oriented transtibial drilled femoral tunnel incorporates portions of the anteromedial and posterolateral bundle origins of the native anterior cruciate ligament. A laterally oriented transtibial drilled

  7. 77 FR 45588 - Tapered Roller Bearings and Parts Thereof, Finished and Unfinished, From the People's Republic of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-01

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-601] Tapered Roller Bearings and... new shipper review (``NSR'') of the antidumping duty order on tapered roller bearings from the People... The notice announcing the antidumping duty order on tapered roller bearings from the PRC was published...

  8. 76 FR 6397 - Tapered Roller Bearings and Parts Thereof, Finished and Unfinished From the People's Republic of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-04

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-601] Tapered Roller Bearings and... on tapered roller bearings (``TRBs'') from the People's Republic of China (``PRC'') meets the... published in the Federal Register on June 15, 1987. See Antidumping Duty Order; Tapered Roller Bearings and...

  9. 76 FR 45777 - Tapered Roller Bearings and Parts Thereof, Finished and Unfinished From the People's Republic of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-01

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-601] Tapered Roller Bearings and... tapered roller bearings (``TRBs'') from the People's Republic of China (``PRC'') meets the statutory and... Register on June 15, 1987. See Antidumping Duty Order; Tapered Roller Bearings and Parts Thereof, Finished...

  10. A micro-architectural evaluation of osteoporotic human femoral heads to guide implant placement in proximal femoral fractures.

    PubMed

    Jenkins, Paul J; Ramaesh, Rishikesan; Pankaj, Pankaj; Patton, James T; Howie, Colin R; Goffin, Jérôme M; Merwe, Andrew van der; Wallace, Robert J; Porter, Daniel E; Simpson, A Hamish

    2013-10-01

    The micro-architecture of bone has been increasingly recognized as an important determinant of bone strength. Successful operative stabilization of fractures depends on bone strength. We evaluated the osseous micro-architecture and strength of the osteoporotic human femoral head. 6 femoral heads, obtained during arthroplasty surgery for femoral neck fracture, underwent micro-computed tomography (microCT) scanning at 30 μm, and bone volume ratio (BV/TV), trabecular thickness, structural model index, connection density, and degree of anisotropy for volumes of interest throughout the head were derived. A further 15 femoral heads underwent mechanical testing of compressive failure stress of cubes of trabecular bone from different regions of the head. The greatest density and trabecular thickness was found in the central core that extended from the medial calcar to the physeal scar. This region also correlated with the greatest degree of anisotropy and proportion of plate-like trabeculae. In the epiphyseal region, the trabeculae were organized radially from the physeal scar. The weakest area was found at the apex and peripheral areas of the head. The strongest region was at the center of the head. The center of the femoral head contained the strongest trabecular bone, with the thickest, most dense trabeculae. The apical region was weaker. From an anatomical and mechanical point of view, implants that achieve fixation in or below this central core may achieve the most stable fixation during fracture healing.

  11. Asymmetrical dual tapered fiber Mach-Zehnder interferometer for fiber-optic directional tilt sensor.

    PubMed

    Lee, Cheng-Ling; Shih, Wen-Cheng; Hsu, Jui-Ming; Horng, Jing-Shyang

    2014-10-06

    This work proposes a novel, highly sensitive and directional fiber tilt sensor that is based on an asymmetrical dual tapered fiber Mach-Zehnder interferometer (ADTFMZI). The fiber-optic tilt sensor consists of two abrupt tapers with different tapered waists into which are incorporated a set of iron spheres to generate an asymmetrical strain in the ADTFMZI that is correlated with the tilt angle and the direction of inclination. Owing to the asymmetrical structure of the dual tapers, the proposed sensor can detect the non-horizontal/horizontal state of a structure and whether the test structure is tilted to clockwise or counterclockwise by measuring the spectral responses. Experimental results show that the spectral wavelengths are blue-shifted and red-shifted when the sensor tilts to clockwise (-θ) and counterclockwise ( + θ), respectively. Tilt angle sensitivities of about 335 pm/deg. and 125 pm/deg. are achieved in the -θ and + θ directions, respectively, when the proposed sensing scheme is utilized.

  12. Femoral neck radiography: effect of flexion on visualization.

    PubMed

    Garry, Steven C; Jhangri, Gian S; Lambert, Robert G W

    2005-06-01

    To determine whether flexion improves radiographic visualization of the femoral neck when the femur is externally rotated. Five human femora, with varying neck-shaft and anteversion angles, were measured and immobilized. Degree of flexion required to bring the femoral neck horizontal was measured, varying the rotation. Next, one bone was radiographed in 16 positions, varying rotation in 15 degrees and flexion in 10 degrees increments. Radiographs were presented in randomized blinded fashion to 15 staff radiologists for scoring of femoral neck visualization. Following this, all 5 bones were radiographed in 4 positions of rotation and at 0 degree and 20 degrees flexion, and blinded randomized review of radiographs was repeated. Comparisons between angles and rotations were made using the Mann-Whitney test. The flexion angle required to bring the long axis of the femoral neck horizontal correlated directly with the degree of external rotation (p < 0.05). Visualization of the femoral neck in the extended position progressively deteriorated from 15 degrees internal rotation to 30 degrees external rotation (p < 0.01). However, when 20 degrees flexion was applied to bones in external rotation, visualization significantly improved at 15 degrees (p < 0.05) and 30 degrees (p < 0.01). Flexion of the externally rotated femur can bring the femoral neck into horizontal alignment, and a relatively small amount (20 degrees) of flexion can significantly improve radiographic visualization. This manoeuvre could be useful for radiography of the femoral neck when initial radiographs are inadequate because of external rotation of the leg.

  13. Compatible taper algorithms for California hardwoods

    Treesearch

    James W. Flewelling

    2007-01-01

    For 13 species of California hardwoods, cubic volume equations to three merchantability standards had been developed earlier. The equations predict cubic volume from the primary bole, forks, and branches, but do not differentiate between the sources of the wood. The Forest Inventory and Analysis (FIA) program needed taper equations that are compatible with the volume...

  14. Surgery for pathological proximal femoral fractures, excluding femoral head and neck fractures: resection vs. stabilisation.

    PubMed

    Zacherl, Max; Gruber, Gerald; Glehr, Mathias; Ofner-Kopeinig, Petra; Radl, Roman; Greitbauer, Manfred; Vecsei, Vilmos; Windhager, Reinhard

    2011-10-01

    Pathological femoral head and neck fractures are commonly treated by arthroplasty. Treatment options for the trochanteric region or below are not clearly defined. The purpose of this retrospective, comparative, double-centre study was to analyse survival and influences on outcome according to the surgical technique used to treat pathological proximal femoral fractures, excluding fractures of the femoral head and neck. Fifty-nine patients with 64 fractures were operated up on between 1998 and 2004 in two tertiary referral centres and divided into two groups. One group (S, n = 33) consisted of patients who underwent intramedullary nailing alone, and the other group (R, n = 31) consisted of patients treated by metastatic tissue resection and reconstruction by means of different implants. Median survival was 12.6 months with no difference between groups. Surgical complications were higher in the R group (n = 7) vs. the S group (n = 3), with no statistically significant difference. Patients with surgery-related complications had a higher survival rate (p = 0.049), as did patients with mechanical implant failure (p = 0.01). Survival scoring systems did not correlate with actual survival. Resection of metastases in patients with pathological fractures of the proximal femur, excluding femoral head and neck fractures, has no influence on survival. Patients with long postoperative survival prognosis are at risk of implant-related complications.

  15. Effects of self-adjusting file, Mtwo, and ProTaper on the root canal wall.

    PubMed

    Hin, Ellemieke S; Wu, Min-Kai; Wesselink, Paul R; Shemesh, Hagay

    2013-02-01

    The purpose of this ex vivo study was to observe the incidence of cracks in root dentin after root canal preparation with hand files, self-adjusting file (SAF), ProTaper, and Mtwo. One hundred extracted mandibular premolars with single canals were randomly selected. Two angulated radiographs were taken for each tooth, and the width of the canal was measured at 9 mm from the apex. Five groups of 20 teeth each were comparable in canal width. The control group was left unprepared. Four experimental groups were instrumented with hand files, ProTaper, Mtwo, and SAF. Roots were then sectioned horizontally and observed under a microscope. The presence of dentinal cracks and their location were noted. The difference between the experimental groups was analyzed with a χ(2) test. No cracks were observed in the control group. In the experimental groups, ProTaper, Mtwo, and SAF caused cracks in 35%, 25%, and 10% of teeth, respectively. The hand-file group did not show any dentinal cracks (P < .0001). ProTaper and Mtwo caused more cracks than hand files (P < .05), but SAF did not (P > .05). Instrumentation of root canals with SAF, Mtwo, and ProTaper could cause damage to root canal dentin. SAF has a tendency to cause less dentinal cracks as compared with ProTaper or Mtwo. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. 3D geometrical assessment of femoral curvature: a reverse engineering technique.

    PubMed

    Chantarapanich, Nattapon; Sitthiseripratip, Kriskrai; Mahaisavariya, Banchong; Wongcumchang, Marut; Siribodhi, Pongwit

    2008-09-01

    Investigate the 2D/3D geometry of femoral curvature and femoral length using the advanced technique of computerized tomography combined with reverse engineering techniques. The present study was performed using reverse engineering technique based on CT data of 99 cadaveric femora. The femur was divided into three segments, proximal, mid-shaft, and distal regions by defining 35% and 65% of the femoral total length as a boundary of each region. The intramedullary canal in the mid-shaft region was mainly extracted to determine the set of circular center, which could consequence to approximate the 3D femoral radius of curvature using the 3D least square best fit. The 3D femoral curvature was then projected into A-P and M-L directions to investigate the correlation of 2D/3D femoral curvature as normal radiographic images. It was found that the average 3D Thai femoral curvature was 895.46-mm (SD = 238.06) and the average femoral total length is 421.96-mm (SD = 27.61). In addition, the 2D femoral curvature derived from sagittal radiographic image can be used to determine the 3D femoral curvature with this equation: R3D = RSagittal + 3.67 with r = 0.987. This described technique is a non-destructive method that can effectively assess the internal/ external 3D geometric data of the femur The obtained data is useful to develop a proper design of prosthesis that required inserting into the intramedullary canal. From the present study, it can be concluded that the 2DSagittal femoral curvature derived from standard radiographic image can be represented for the 3D femoral curvature.

  17. The Cervical Spinal Canal Tapers Differently in Patients with Chiari I with and without Syringomyelia.

    PubMed

    Thompson, A; Madan, N; Hesselink, J R; Weinstein, G; Munoz del Rio, A; Haughton, V

    2016-04-01

    The cause of syringomyelia in patients with Chiari I remains uncertain. Cervical spine anatomy modifies CSF velocities, flow patterns, and pressure gradients, which may affect the spinal cord. We tested the hypothesis that cervical spinal anatomy differs between Chiari I patients with and without syringomyelia. We identified consecutive patients with Chiari I at 3 institutions and divided them into groups with and without syringomyelia. Five readers measured anteroposterior cervical spinal diameters, tonsillar herniation, and syrinx dimensions on cervical MR images. Taper ratios for C1-C7, C1-C4, and C4-C7 spinal segments were calculated by linear least squares fitting to the appropriate spinal canal diameters. Mean taper ratios and tonsillar herniation for groups were compared and tested for statistical significance with a Kruskal-Wallis test. Inter- and intrareader agreement and correlations in the data were measured. One hundred fifty patients were included, of which 49 had syringomyelia. C1-C7 taper ratios were smaller and C4-C7 taper ratios greater for patients with syringomyelia than for those without it. C1-C4 taper ratios did not differ significantly between groups. Patients with syringomyelia had, on average, greater tonsillar herniation than those without a syrinx. However, C4-C7 taper ratios were steeper, for all degrees of tonsil herniation, in patients with syringomyelia. Differences among readers did not exceed differences among patient groups. The tapering of the lower cervical spine may contribute to the development of syringomyelia in patients with Chiari I. © 2016 by American Journal of Neuroradiology.

  18. Validation of Volume and Taper Equations For Loblolly Shortleaf and Slash Pine

    Treesearch

    Allan E. Tiarks; V. Clark Baldwin

    1999-01-01

    Inside-bark diameter measurements at 6.64 intervals of 137 loblolly, 52 shortleaf, and 64 slash pines were used to calculate the actual volume and taper of each species for comparison with volumes and tapers predicted from published equations. The loblolly pine were cut in Texas (TX) and Louisiana (LA) while the shortleaf was sampled only in TX. The slash pine were...

  19. Design and Synthesis of Network-Forming Triblock Copolymers Using Tapered Block Interfaces

    PubMed Central

    Kuan, Wei-Fan; Roy, Raghunath; Rong, Lixia; Hsiao, Benjamin S.; Epps, Thomas H.

    2012-01-01

    We report a strategy for generating novel dual-tapered poly(isoprene-b-isoprene/styrene-b-styrene-b-styrene/methyl methacrylate-b-methyl methacrylate) [P(I-IS-S-SM-M)] triblock copolymers that combines anionic polymerization, atom transfer radical polymerization (ATRP), and Huisgen 1,3-dipolar cycloaddition click chemistry. The tapered interfaces between blocks were synthesized via a semi-batch feed using programmable syringe pumps. This strategy allows us to manipulate the transition region between copolymer blocks in triblock copolymers providing control over the interfacial interactions in our nanoscale phase-separated materials independent of molecular weight and block constituents. Additionally, we show the ability to retain a desirous and complex multiply-continuous network structure (alternating gyroid) in our dual-tapered triblock material. PMID:23066522

  20. The experimental and calculated characteristics of 22 tapered wings

    NASA Technical Reports Server (NTRS)

    Anderson, Raymond F

    1938-01-01

    The experimental and calculated aerodynamic characteristics of 22 tapered wings are compared, using tests made in the variable-density wind tunnel. The wings had aspect ratios from 6 to 12 and taper ratios from 1:6:1 and 5:1. The compared characteristics are the pitching moment, the aerodynamic-center position, the lift-curve slope, the maximum lift coefficient, and the curves of drag. The method of obtaining the calculated values is based on the use of wing theory and experimentally determined airfoil section data. In general, the experimental and calculated characteristics are in sufficiently good agreement that the method may be applied to many problems of airplane design.

  1. Manipulation of spontaneous emission in a tapered photonic crystal fibre

    NASA Astrophysics Data System (ADS)

    Myers, S. J.; Fussell, D. P.; Dawes, J. M.; Mägi, E.; McPhedran, R. C.; Eggleton, B. J.; de Sterke, C. Martijn

    2006-12-01

    We characterize the spontaneous emission of dye that is introduced into the central core of a tapered photonic crystal fiber. Since the photonic crystal period in the fibre cladding varies along the taper, the transmission and spontaneous emission spectra over a wide range of relative frequencies can be observed. The spontaneous emission spectra of the fibre transverse to the fiber axis show suppression due to partial band-gaps of the structure, and also enhancement of spontaneous emission near the band edges. We associate these with van Hove features, as well as finite cluster size effects.

  2. Ten-Year Outcome of Serum Metal Ion Levels After Primary Total Hip Arthroplasty

    PubMed Central

    Levine, Brett R.; Hsu, Andrew R.; Skipor, Anastasia K.; Hallab, Nadim J.; Paprosky, Wayne G.; Galante, Jorge O.; Jacobs, Joshua J.

    2013-01-01

    Abstract: We previously reported on the metal ion concentrations of cobalt, chromium, and titanium that were found in the serum of patients three years after they had undergone primary total hip arthroplasty as compared with the concentrations found in the serum of control patients who did not have an implant. This study is a concise update on the serum metal levels found in a cohort of these patients ten years after the time of hip implantation. Of the original seventy-five subjects, metal ion levels were available for forty patients (53%). Ten patients (hybrid group) had received a hybrid total hip replacement that consisted of a modular cobalt-alloy femoral stem with a cobalt-alloy femoral head that had been inserted with cement and a titanium acetabular socket that had been inserted without cement. Nine patients (cobalt-chromium [CoCr] group) had received an implant with an extensively porous-coated modular cobalt-alloy femoral stem and femoral head along with a titanium acetabular socket; the femoral and acetabular components had each been inserted without cement. Eight patients (titanium group) had undergone insertion of a proximally porous-coated modular titanium-alloy femoral stem with a cobalt-alloy femoral head and a titanium acetabular socket; the femoral and acetabular components had each been inserted without cement. Thirteen patients (control group) from the original control group of patients who had not received an implant served as control subjects. Serum metal levels were measured with use of high-resolution sector field inductively coupled plasma mass spectrometry. The hybrid total hip arthroplasty group had mean cobalt levels that were 3.2 times higher at 120 months than they were at baseline, and the cobalt levels in that group were significantly higher than those in the titanium total hip arthroplasty group at thirty-six, sixty, eighty-four, ninety-six, and 120 months (p < 0.01). The hybrid group had mean chromium levels that were 3.9 times

  3. Adiabatically tapered splice for selective excitation of the fundamental mode in a multimode fiber.

    PubMed

    Jung, Yongmin; Jeong, Yoonchan; Brambilla, Gilberto; Richardson, David J

    2009-08-01

    We propose a simple and effective method to selectively excite the fundamental mode of a multimode fiber by adiabatically tapering a fusion splice to a single-mode fiber. We experimentally demonstrate the method by adiabatically tapering splice (taper waist=15 microm, uniform length=40 mm) between single-mode and multimode fiber and show that it provides a successful mode conversion/connection and allows for almost perfect fundamental mode excitation in the multimode fiber. Excellent beam quality (M(2) approximately 1.08) was achieved with low loss and high environmental stability.

  4. Experimental results for characterization of a tapered plastic optical fiber sensor based on SPR

    NASA Astrophysics Data System (ADS)

    Cennamo, N.; Galatus, R.; Zeni, L.

    2015-05-01

    The experimental results obtained with two different Plastic Optical Fiber (POF) geometries, tapered and not-tapered, for a sensor based on Surface Plasmon Resonance (SPR) are presented. SPR is used for determining the refractive index variations at the interface between a gold layer and a dielectric medium (aqueous medium). In this work SPR sensors in POF configurations, useful for bio-sensing applications, have been realized for the optimization of the sensitivity and experimentally tested. The results show as the sensitivity increases with the tapered POF configuration, when the refractive index of aqueous medium increases.

  5. Portable fiber-optic taper coupled optical microscopy platform

    NASA Astrophysics Data System (ADS)

    Wang, Weiming; Yu, Yan; Huang, Hui; Ou, Jinping

    2017-04-01

    The optical fiber taper coupled with CMOS has advantages of high sensitivity, compact structure and low distortion in the imaging platform. So it is widely used in low light, high speed and X-ray imaging systems. In the meanwhile, the peculiarity of the coupled structure can meet the needs of the demand in microscopy imaging. Toward this end, we developed a microscopic imaging platform based on the coupling of cellphone camera module and fiber optic taper for the measurement of the human blood samples and ascaris lumbricoides. The platform, weighing 70 grams, is based on the existing camera module of the smartphone and a fiber-optic array which providing a magnification factor of 6x.The top facet of the taper, on which samples are placed, serves as an irregular sampling grid for contact imaging. The magnified images of the sample, located on the bottom facet of the fiber, are then projected onto the CMOS sensor. This paper introduces the portable medical imaging system based on the optical fiber coupling with CMOS, and theoretically analyzes the feasibility of the system. The image data and process results either can be stored on the memory or transmitted to the remote medical institutions for the telemedicine. We validate the performance of this cell-phone based microscopy platform using human blood samples and test target, achieving comparable results to a standard bench-top microscope.

  6. Titanium disilicide formation by sputtering of titanium on heated silicon substrate

    NASA Astrophysics Data System (ADS)

    Tanielian, M.; Blackstone, S.

    1984-09-01

    We have sputter deposited titanium on bare silicon substrates at elevated temperatures. We find that at a substrate temperature of about 515 °C titanium silicide is formed due to the reaction of the titanium with the Si. The resistivity of the silicide is about 15 μΩ cm and it is not etchable in a selective titanium etch. This process can have applications in low-temperature, metal-oxide-semiconductor self-aligned silicide formation for very large scale integrated

  7. Comparative study of 6 rotary nickel-titanium systems and hand instrumentation for root canal preparation in severely curved root canals of extracted teeth.

    PubMed

    Celik, Davut; Taşdemir, Tamer; Er, Kürşat

    2013-02-01

    Some improvements have been developed with new generations of nickel-titanium (NiTi) rotary instruments that led to their successful and extensive application in clinical practice. The purpose of this in vitro study was to compare the root canal preparations performed by using GT Series X and Twisted File systems produced by innovative manufacturing process with Revo-S, RaCe, Mtwo, and ProTaper Universal systems manufactured directly from conventional nitinol and with stainless steel K-Flexofile instruments. The mesiobuccal root canals of 140 maxillary first permanent molars that had between 30°-40° curvature angle and 4- to 9-mm curvature radius of the root canal were used. After root canal preparations made by using GT Series X, Twisted File, Revo-S, RaCe, Mtwo, and ProTaper Universal NiTi rotary systems and stainless steel K-Flexofile instruments, transportation occurred in the root canal, and alteration of working length (WL) was assessed by using a modified double-digital radiographic technique. The data were compared by the post hoc Tukey honestly significant difference test. NiTi rotary systems caused less canal transportation and alteration of WL than K-Flexofile instruments (P < .05). There was no significant difference between NiTi rotary system groups at any levels (P > .05) except 2.5 mm from the WL. At this level ProTaper Universal system caused significant canal transportation (P < .05). GT Series X and Twisted File rotary systems produced with innovative process were concluded to shape the curved canals to result in minimal canal transportation, similar to Revo-S, RaCe, Mtwo, and ProTaper Universal rotary systems manufactured by traditional methods. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  8. Preparation of titanium diboride powder

    DOEpatents

    Brynestad, Jorulf; Bamberger, Carlos E.

    1985-01-01

    Finely-divided titanium diboride or zirconium diboride powders are formed by reacting gaseous boron trichloride with a material selected from the group consisting of titanium powder, zirconium powder, titanium dichloride powder, titanium trichloride powder, and gaseous titanium trichloride.

  9. Tapered microelectrode array system for dielectrophoretically filtration: fabrication, characterization, and simulation study

    NASA Astrophysics Data System (ADS)

    Buyong, Muhamad Ramdzan; Larki, Farhad; Takamura, Yuzuru; Majlis, Burhanuddin Yeop

    2017-10-01

    This paper presents the fabrication, characterization, and simulation of microelectrode arrays system with tapered profile having an aluminum surface for dielectrophoresis (DEP)-based manipulation of particles. The proposed structure demonstrates more effective electric field gradient compared with its counterpart with untapered profile. Therefore, according to the asymmetric distribution of the electric field in the active region of microelectrode, it produces more effective particle manipulation. The tapered aluminum microelectrode array (TAMA) fabrication process uses a state-of-the-art technique in the formation of the resist's taper profile. The performance of TAMA with various sidewall profile angles (5 deg to 90 deg) was analyzed through finite-element method numerical simulations to offer a better understanding of the origin of the sidewall profile effect. The ability of capturing and manipulating of the device was examined through modification of the Clausius-Mossotti factor and cross-over frequency (f). The fabricated system has been particularly implemented for filtration of particles with a desired diameter from a mixture of particles with three different diameters in an aqueous medium. The microelectrode system with tapered side wall profile offers a more efficient platform for particle manipulation and sensing applications compared with the conventional microelectrode systems.

  10. Theoretical investigation for excitation light and fluorescence signal of fiber optical sensor using tapered fiber tip.

    PubMed

    Yuan, Yinquan; Ding, Liyun

    2011-10-24

    For fiber optical sensor made of tapered fiber tip, the effects of the geometrical parameters of tapered tip on two important factors have been investigated. One factor is the intensity of the evanescent wave into fluorescent layer through core-medium interface; the other is the intensity of fluorescence signal transmitted from fluorescent layer to measurement end. A dependence relation of the intensity of fluorescence signal transmitted from fluorescent layer to measurement end upon the geometrical parameters of tapered tip has been obtained. Theoretical results show that the intensity of the evanescent wave into fluorescent layer rises with the decrease of the end diameter of tapered tip, and the increase of the tip length; and the transmitted power of fluorescence signal increases linearly with the increase of the tip length due to the contribution of the side area of tapered tip. © 2011 Optical Society of America

  11. Mid-IR soliton compression in silicon optical fibers and fiber tapers.

    PubMed

    Peacock, Anna C

    2012-03-01

    Numerical simulations are used to investigate soliton compression in silicon core optical fibers at 2.3 μm in the mid-infrared waveguide regime. Compression in both standard silicon fibers and fiber tapers is compared to establish the relative compression ratios for a range of input pulse conditions. The results show that tapered fibers can be used to obtain higher levels of compression for moderate soliton orders and thus lower input powers. © 2012 Optical Society of America

  12. Femoral Head Avascular Necrosis Is Not Caused by Arthroscopic Posterolateral Femoroplasty.

    PubMed

    Rupp, Robert E; Rupp, Sasha N

    2016-05-01

    This study was conducted to identify the risk of avascular necrosis of the femoral head after arthroscopic femoroplasty extending to the posterolateral femoral neck, the source of the primary blood supply to the femoral head. Cam lesions of femoroacetabular impingement are typically anterior along the junction of the femoral head and neck. However, anatomic variations can involve the posterolateral vascular region of the femoral head and neck. Femoroplasty involving this vascular region can lead to injury to the blood supply to the femoral head, with subsequent avascular necrosis. If the posterolateral portion of the cam lesion is preserved, persistent femoroacetabular impingement may occur. A retrospective review identified 112 patients who underwent arthroscopic femoroplasty for femoroacetabular impingement over a 2-year period. Of these patients, 14 had femoroplasty that extended to the posterolateral femoral head. Of this group, 5 had undergone magnetic resonance imaging (MRI) after femoroplasty and the other 9 were contacted to undergo MRI of the hip to evaluate for avascular necrosis. A radiologist and the senior author evaluated all MRI scans specifically for avascular necrosis of the femoral head. All procedures were performed by the senior author. Mean age of the 14 patients (8 women and 6 men) with femoroplasty that extended into the posterolateral vascular region of the femoral head was 44 years (range, 23-69 years). All 14 patients underwent MRI evaluation of the affected hip a mean of 25 months (range, 7-44 months) after femoroplasty. No MRI scans showed evidence of avascular necrosis of the femoral head. Femoroplasty of the posterolateral vascular region of the femoral head is not associated with avascular necrosis. Patients with femoroacetabular impingement and a cam lesion extending to the posterolateral femoral head can undergo femoroplasty of this region without the development of avascular necrosis. [Orthopedics. 2016; 39(3):177-180.]. Copyright

  13. [Femoral artery pseudoaneurysms encountered in orthopedics and traumatology].

    PubMed

    Raherinantenaina, F; Rajaonanahary, T M A; Rakoto Ratsimba, H N

    2015-12-01

    Most published articles regarding orthopedic- and trauma-related femoral artery pseudoaneurysms (FAPs) are case reports in English. Reported cases are often associated with a literature review but actually provide little robust data. We wanted to summarize the current knowledge on diagnostic and therapeutic features of these FAPs. A new case of superficial FAP is described followed by a review of the literature. A bibliographic search was performed online (PubMed, ScinceDirect) from 1964 to 2015 using the descriptors "traumatic femoral pseudoaneurysm, orthopedic surgery, osteochondroma". A total of 64 cases of FAPs was analyzed. There were 50 men with an average age of 40.72±26.45 years old. The most common clinical presentation was painful swelling (34%). Arteriography was the commonest radiological investigation used (63%). The main etiologies were orthopedic injuries (47%), surgery of the upper thigh (30%) and femoral osteochondromas (23%). Arterial injuries included superficial femoral (47%) and profunda femoris artery (50%). The treatment was open surgery (56%) or endovascular repair (36%). Deep femoral artery and its branches were embolized (47%) or ligated (38%). Endovascular stenting was performed in 30% of posttraumatic FAPs. All FAPs relating to osteochondromas were repaired surgically. Postoperative courses were uneventful in 95% of patients. Endovascular embolization is preferred in management of postsurgical FAPs which have usually involved the deep femoral artery. Endovascular stenting graft may be proposed for posttraumatic FAPs, for which the superficial femoral trunk is the most often involved vessel. Surgical repair should be performed when endovascular stenting graft is not feasible. Surgical repair is mandatory for all FAPs secondary to traumatic exostoses. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  14. [Treatment of beginning juvenile detachment of the femoral head, taking growth of the femoral neck into account (author's transl)].

    PubMed

    Engelhardt, P

    1979-10-01

    Prevention of further detachment is the primary aim in the immediate treatment of beginning juvenile detachment of the femoral head. Screwing of the epiphysis of the head, first introduced by M. E. Mueller (1965), has proved successful. Besides providing immediate mechanical stability, this method, however, results in premature ossification of the joint of the femoral neck. Epiphysiodesis has a particularly unfavourable effect in early childhood, because it inhibits proper growth of the leg and development of the mechanism of the hip joint on account of the shortened femoral neck. Spiking of the epiphysis with Krischner screw wires guarantees safe fixation of the epiphyseal head on the one hand, and sufficient freedom of femoral neck growth on the other. Surgical treatment requires knowledge of the changed hip joint anatomy of the child. Preoperative planning via drawing to determine the length and position of the implantate on the basis of standardised x-ray films, will help to prevent operative failures.

  15. Defining the common femoral artery: Insights from the femoral arterial access with ultrasound trial.

    PubMed

    Seto, Arnold H; Tyler, Jeffrey; Suh, William M; Harrison, Alexander T; Vera, Jesus A; Zacharias, Soni J; Daly, Timothy S; Sparling, Jeffrey M; Patel, Pranav M; Kern, Morton J; Abu-Fadel, Mazen

    2017-06-01

    We sought to establish the typical location of the common femoral artery (CFA) bifurcation, the origin and most inferior reflection of the inferior epigastric artery (IEA) relative to the femoral head (FH) and whether patient demographics predicted anatomical variations. In the absence of ultrasound guidance or prior imaging, the precise location of the CFA bifurcation and IEA can only be determined following access site angiography. Fluoroscopic landmarks are commonly used to estimate the location of the CFA bifurcation, but the position of the IEA is less well characterized. Prospectively collected data on 989 patients with femoral angiography in the FAUST trial were analyzed. The level of CFA bifurcation and the origin and most inferior reflection of the IEA were classified by angiography. Logistic regression was used to explore whether baseline demographics were associated with anatomic variations. The CFA bifurcation occurs below the middle 1/3 rd of the femoral head in 95% of patients, and no patient factors are predictive of a high bifurcation. The IEA origin has a more variable anatomically pattern, with high BSA, male gender, and white race associated with a low IEA origin. Operators should attempt to access the CFA at the level of the middle 1/3 rd of the FH to maximize the chance of CFA cannulation. However, this location carries an 11% risk of being at or above the IEA origin. Baseline demographics were of limited utility for predicting anatomic variants of the CFA bifurcation and the course of the IEA. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  16. A new rule for femoral nerve blocks.

    PubMed

    Schulz-Stübner, Sebastian; Henszel, Angela; Hata, J Steven

    2005-01-01

    Acupuncture points are described by use of a proportional system that is based on the width of the thumb at the level of the distal interphalangeal joint, defined as 1 CUN. Our study tested first the correlation between the CUN and weight and height in 500 Americans and second the hypothesis that the CUN system is superior to the conventional landmarks to localize the femoral nerve 1 or 2 cm lateral to the artery in a prospective, double-blinded, randomized study. Sixty-two patients were randomized to receive a femoral nerve block by a needle entry point either 1 CUN lateral, 1 cm lateral, or 2 cm lateral to the femoral artery at the level of the inguinal crease. The time from needle entry to injection of local anesthetic was measured by an investigator blind to the technique, who also counted the frequency of needle repositioning, graded the ease of the block and its success, and registered complications. Good correlation occurred between weight and CUN (r = 0.79) and height and CUN (r = 0.83), which indicates that the CUN of a normal person (predefined as 175 cm tall and 70 kg weight) is 18.7 +/- 1 mm. In the CUN group, the femoral block was achieved significantly faster (P < .01) with fewer attempts (P < .003). The success rate was the same and complications did not differ significantly between the groups. A needle insertion point 1 CUN lateral to the midpoint of the palpated femoral artery at the level of the inguinal crease makes femoral nerve blocks faster and easier compared with conventional landmark 1 cm to 2 cm lateral to the artery.

  17. Membrane voltage changes in passive dendritic trees: a tapering equivalent cylinder model.

    PubMed

    Poznański, R R

    1988-01-01

    An exponentially tapering equivalent cylinder model is employed in order to approximate the loss of the dendritic trunk parameter observed from anatomical data on apical and basilar dendrites of CA1 and CA3 hippocampal pyramidal neurons. This model allows dendritic trees with a relative paucity of branching to be treated. In particular, terminal branches are not required to end at the same electrotonic distance. The Laplace transform method is used to obtain analytic expressions for the Green's function corresponding to an instantaneous pulse of current injected at a single point along a tapering equivalent cylinder with sealed ends. The time course of the voltage in response to an arbitrary input is computed using the Green's function in a convolution integral. Examples of current input considered are (1) an infinitesimally brief (Dirac delta function) pulse and (2) a step pulse. It is demonstrated that inputs located on a tapering equivalent cylinder are more effective at the soma than identically placed inputs on a nontapering equivalent cylinder. Asymptotic solutions are derived to enable the voltage response behaviour over both relatively short and long time periods to be analysed. Semilogarithmic plots of these solutions provide a basis for estimating the membrane time constant tau m from experimental transients. Transient voltage decrement from a clamped soma reveals that tapering tends to reduce the error associated with inadequate voltage clamping of the dendritic membrane. A formula is derived which shows that tapering tends to increase the estimate of the electrotonic length parameter L.

  18. Influence of rotational speed on the cyclic fatigue of rotary nickel-titanium endodontic instruments.

    PubMed

    Lopes, Hélio P; Ferreira, Alessandra A P; Elias, Carlos N; Moreira, Edson J L; de Oliveira, Júlio C Machado; Siqueira, José F

    2009-07-01

    During the preparation of curved canals, rotary nickel-titanium (NiTi) instruments are subjected to cyclic fatigue, which can lead to instrument fracture. Although several factors may influence the cyclic fatigue resistance of instruments, the role of the rotational speed remains uncertain. This study was intended to evaluate the effects of rotational speed on the number of cycles to fracture of rotary NiTi instruments. ProTaper Universal instruments F3 and F4 (Maillefer SA, Ballaigues, Switzerland) were used in an artificial curved canal under rotational speeds of 300 rpm or 600 rpm. The artificial canal was made of stainless steel, with an inner diameter of 1.5 mm, total length of 20 mm, and arc at the end with a curvature radius of 6 mm. The arc length was 9.4 mm and 10.6 mm on the straight part. The number of cycles required to fracture was recorded. Fractured surfaces and the helical shafts of the fractured instruments were analyzed by scanning electron microscopy. The results showed approximately a 30% reduction in the observed number of cycles to fracture as rotational speed was increased from 300 to 600 RPM (p < 0.05). The morphology of the fractured surface was always of ductile type, and no plastic deformation was observed on the helical shaft of fractured instruments. The present findings for both F3 and F4 ProTaper instruments revealed that the increase in rotational speed significantly reduced the number of cycles to fracture.

  19. Segmented polynomial taper equation incorporating years since thinning for loblolly pine plantations

    Treesearch

    A. Gordon Holley; Thomas B. Lynch; Charles T. Stiff; William Stansfield

    2010-01-01

    Data from 108 trees felled from 16 loblolly pine stands owned by Temple-Inland Forest Products Corp. were used to determine effects of years since thinning (YST) on stem taper using the Max–Burkhart type segmented polynomial taper model. Sample tree YST ranged from two to nine years prior to destructive sampling. In an effort to equalize sample sizes, tree data were...

  20. [Midterm follow-up results on Asian femoral intramedullary nail for the treatment of segmental and comminuted femoral fractures].

    PubMed

    Li, Lang; Gao, Feng; Huang, Qi; Li, Qiang; Xie, Lin; Zhang, Bin

    2016-06-01

    To investigate midterm follow-up results on Asian femoral intramedullary nail in treating segmental and comminuted femoral fractures. Between June 2011 and October 2012,16 patients with segmental and comminuted femoral fractures were treated with minimally invasive reset and Asian femoral intramedullary nail under extension table. Among them, there were 10 males and 6 females aged from 21 to 49 years old with an average of 34.5 years old; the time from injury to operation ranged from 3 to 24 d with an average of 9.1 d. There were 6 cases were type C1,2 cases were type C2 and 8 cases were type C3 according to AO classification. X-ray of femoral segment at 3,6 and 12 months after operation were applied for evaluating fracture healing. Harris score of hip joint and HSS score of knee joint were used to evaluate postoperative function. All patients were followed up from 24 to 36 months with an average of 28.4 months. Operative time was from 88 to 112 min with an average of 90.7 min; blood loss ranged from 150 to 200 ml with an average of 188.75 ml; the time of fracture healing was from 5 to 9 months with an average of 5.4 months. All incision were healed at stage I. No loosening, breakage of internal fixation and displacement of fracture were occurred. There were no significant differences in Harris score of hip joint at 3, 6 and 12 months after operation (F = 0.07, P = 0.893 > 0.05), 10 cases obtained excellent results, 5 good and 1 moderate. There was no obvious meaning in HSS score of knee joint (F = 0.08,P = 0.876 > 0.05), 9 cases obtained excellent results, 6 good and 1 poor. Asian femoral intramedullary nail could treat segmental and comminuted femoral fractures by using variety of less invasive ways,which has advantages of less trauma, quick recovery of function and satisfied midterm following-up results. But long term following-up effects remains to be seen.

  1. Artificial Intelligence Procedures for Tree Taper Estimation within a Complex Vegetation Mosaic in Brazil.

    PubMed

    Nunes, Matheus Henrique; Görgens, Eric Bastos

    2016-01-01

    Tree stem form in native tropical forests is very irregular, posing a challenge to establishing taper equations that can accurately predict the diameter at any height along the stem and subsequently merchantable volume. Artificial intelligence approaches can be useful techniques in minimizing estimation errors within complex variations of vegetation. We evaluated the performance of Random Forest® regression tree and Artificial Neural Network procedures in modelling stem taper. Diameters and volume outside bark were compared to a traditional taper-based equation across a tropical Brazilian savanna, a seasonal semi-deciduous forest and a rainforest. Neural network models were found to be more accurate than the traditional taper equation. Random forest showed trends in the residuals from the diameter prediction and provided the least precise and accurate estimations for all forest types. This study provides insights into the superiority of a neural network, which provided advantages regarding the handling of local effects.

  2. Sealing glasses for titanium and titanium alloys

    DOEpatents

    Brow, Richard K.; Watkins, Randall D.

    1992-01-01

    Glass compositions containing CaO, Al.sub.2 O.sub.3, B.sub.2 O.sub.3, SrO and BaO of various combinations of mole % are provided. These compositions are capable of forming stable glass-to-metal seals with titanium and titanium alloys, for use in components such as seals for battery headers.

  3. Sealing glasses for titanium and titanium alloys

    DOEpatents

    Brow, R.K.; Watkins, R.D.

    1988-01-21

    Glass compositions containing CaO, Al/sub 2/O/sub 3/, B/sub 2/O/sub 3/, SrO and BaO of various combinations of mole % are provided. These compositions are capable of forming stable glass-to-metal seals with titanium and titanium alloys, for use in components such as seals for battery headers.

  4. Incidence of apical crack formation and propagation during removal of root canal filling materials with different engine driven nickel-titanium instruments.

    PubMed

    Özyürek, Taha; Tek, Vildan; Yılmaz, Koray; Uslu, Gülşah

    2017-11-01

    To determine the incidence of crack formation and propagation in apical root dentin after retreatment procedures performed using ProTaper Universal Retreatment (PTR), Mtwo-R, ProTaper Next (PTN), and Twisted File Adaptive (TFA) systems. The study consisted of 120 extracted mandibular premolars. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the negative control group. One hundred teeth were prepared, obturated, and then divided into 5 retreatment groups. The retreatment procedures were performed using the following files: PTR, Mtwo-R, PTN, TFA, and hand files. After filling material removal, apical enlargement was done using apical size 0.50 mm ProTaper Universal (PTU), Mtwo, PTN, TFA, and hand files. Digital images of the apical root surfaces were recorded before preparation, after preparation, after obturation, after filling removal, and after apical enlargement using a stereomicroscope. The images were then inspected for the presence of new apical cracks and crack propagation. Data were analyzed with χ 2 tests using SPSS 21.0 software. New cracks and crack propagation occurred in all the experimental groups during the retreatment process. Nickel-titanium rotary file systems caused significantly more apical crack formation and propagation than the hand files. The PTU system caused significantly more apical cracks than the other groups after the apical enlargement stage. This study showed that retreatment procedures and apical enlargement after the use of retreatment files can cause crack formation and propagation in apical dentin.

  5. Apparatus for electrolytically tapered or contoured cavities

    NASA Technical Reports Server (NTRS)

    Williams, L. A. (Inventor)

    1967-01-01

    An electrolytic machining apparatus for forming tapered or contoured cavities in an electrically conductive and electrochemically erodible piece is presented. It supports the workpiece and an electrode for movement relatively toward each other and has means for pumping an electrolyte between the workpiece and the electrode.

  6. Leaching of Titanium and Silicon from Low-Grade Titanium Slag Using Hydrochloric Acid Leaching

    NASA Astrophysics Data System (ADS)

    Zhao, Longsheng; Wang, Lina; Qi, Tao; Chen, Desheng; Zhao, Hongxin; Liu, Yahui; Wang, Weijing

    2018-05-01

    Acid-leaching behaviors of the titanium slag obtained by selective reduction of vanadium-bearing titanomagnetite concentrates were investigated. It was found that the optimal leaching of titanium and silicon were 0.7% and 1.5%, respectively. The titanium and silicon in the titanium slag were firstly dissolved in the acidic solution to form TiO2+ and silica sol, and then rapidly reprecipitated, forming hydrochloric acid (HCl) leach residue. Most of the silicon presented in the HCl leach residue as floccules-like silica gel, while most of the titanium was distributed in the nano-sized rod-like clusters with crystallite refinement and intracrystalline defects, and, as such, 94.3% of the silicon was leached from the HCl leach residue by alkaline desilication, and 96.5% of the titanium in the titanium-rich material with some rutile structure was then digested by the concentrated sulfuric acid. This provides an alternative route for the comprehensive utilization of titanium and silicon in titanium slag.

  7. Cooling arrangement for a tapered turbine blade

    DOEpatents

    Liang, George

    2010-07-27

    A cooling arrangement (11) for a highly tapered gas turbine blade (10). The cooling arrangement (11) includes a pair of parallel triple-pass serpentine cooling circuits (80,82) formed in an inner radial portion (50) of the blade, and a respective pair of single radial channel cooling circuits (84,86) formed in an outer radial portion (52) of the blade (10), with each single radial channel receiving the cooling fluid discharged from a respective one of the triple-pass serpentine cooling circuit. The cooling arrangement advantageously provides a higher degree of cooling to the most highly stressed radially inner portion of the blade, while providing a lower degree of cooling to the less highly stressed radially outer portion of the blade. The cooling arrangement can be implemented with known casting techniques, thereby facilitating its use on highly tapered, highly twisted Row 4 industrial gas turbine blades that could not be cooled with prior art cooling arrangements.

  8. Design of Ultra-Wideband Tapered Slot Antenna by Using Binomial Transformer with Corrugation

    NASA Astrophysics Data System (ADS)

    Chareonsiri, Yosita; Thaiwirot, Wanwisa; Akkaraekthalin, Prayoot

    2017-05-01

    In this paper, the tapered slot antenna (TSA) with corrugation is proposed for UWB applications. The multi-section binomial transformer is used to design taper profile of the proposed TSA that does not involve using time consuming optimization. A step-by-step procedure for synthesis of the step impedance values related with step slot widths of taper profile is presented. The smooth taper can be achieved by fitting the smoothing curve to the entire step slot. The design of TSA based on this method yields results with a quite flat gain and wide impedance bandwidth covering UWB spectrum from 3.1 GHz to 10.6 GHz. To further improve the radiation characteristics, the corrugation is added on the both edges of the proposed TSA. The effects of different corrugation shapes on the improvement of antenna gain and front-to-back ratio (F-to-B ratio) are investigated. To demonstrate the validity of the design, the prototypes of TSA without and with corrugation are fabricated and measured. The results show good agreement between simulation and measurement.

  9. Influence of torque control motors and the operator's proficiency on ProTaper failures.

    PubMed

    Yared, Ghassan; Bou Dagher, Fadia; Kulkarni, Kiran

    2003-08-01

    The purpose of this study was to evaluate the influence of 2 electric torque control motors and operator experience with a specific nickel-titanium rotary instrumentation technique on the incidence of deformation and separation of instruments. ProTaper (PT) nickel-titanium rotary instruments were used at 300 rpm. In the first part of the study, electric high torque control (group 1) and low torque control (group 2) motors were compared. In the second part of the study, 3 operators with varying experience (groups 3, 4, and 5) were also compared. Twenty sets of PT instruments and 100 canals of extracted human molars were used in each group. Each set of PT instruments was used in up to 5 canals and sterilized before each case. For irrigation, 2.5% NaOCl was used. The number of deformed and separated instruments among the groups (within each part of the study) was statistically analyzed for significance with pair-wise comparisons by using the Fisher exact test (alpha =.05). In part 1, instrument deformation and separation did not occur in groups 1 and 2. In part 2, 25 and 12 instruments were deformed and separated, respectively, with the least experienced operator. Instrument deformation and separation did not occur with the most experienced operator. The Fisher exact test revealed a significant difference between groups 3 and 4 with respect to instrument deformation (P =.0296). In addition, the Fisher exact test revealed that the incidence of instrument deformation was statistically different between groups 3 and 5 (P <.0001) and groups 4 and 5 (P =.0018). The incidence of instrument separation was significantly higher in group 5 than in groups 3 and 4 (P =.001). Preclinical training in the use of the PT technique at 300 rpm is crucial to prevent instrument separation and reduce the incidence of instrument deformation. The use of an electric high torque control motor is safe with the experienced operator.

  10. Coherent beam combining architectures for high power tapered laser arrays

    NASA Astrophysics Data System (ADS)

    Schimmel, G.; Janicot, S.; Hanna, M.; Decker, J.; Crump, P.; Erbert, G.; Witte, U.; Traub, M.; Georges, P.; Lucas-Leclin, G.

    2017-02-01

    Coherent beam combining (CBC) aims at increasing the spatial brightness of lasers. It consists in maintaining a constant phase relationship between different emitters, in order to combine them constructively in one single beam. We have investigated the CBC of an array of five individually-addressable high-power tapered laser diodes at λ = 976 nm, in two architectures: the first one utilizes the self-organization of the lasers in an interferometric extended-cavity, which ensures their mutual coherence; the second one relies on the injection of the emitters by a single-frequency laser diode. In both cases, the coherent combining of the phase-locked beams is ensured on the front side of the array by a transmission diffractive grating with 98% efficiency. The passive phase-locking of the laser bar is obtained up to 5 A (per emitter). An optimization algorithm is implemented to find the proper currents in the five ridge sections that ensured the maximum combined power on the front side. Under these conditions we achieve a maximum combined power of 7.5 W. In the active MOPA configuration, we can increase the currents in the tapered sections up to 6 A and get a combined power of 11.5 W, corresponding to a combining efficiency of 76%. It is limited by the beam quality of the tapered emitters and by fast phase fluctuations between emitters. Still, these results confirm the potential of CBC approaches with tapered lasers to provide a high-power and high-brightness beam, and compare with the current state-of-the-art with laser diodes.

  11. Corrosion on the acetabular liner taper from retrieved modular metal-on-metal total hip replacements.

    PubMed

    Gascoyne, Trevor C; Dyrkacz, Richard M; Turgeon, Thomas R; Burnell, Colin D; Wyss, Urs P; Brandt, Jan-M

    2014-10-01

    Eight retrieved metal-on-metal total hip replacements displayed corrosion damage along the cobalt-chromium alloy liner taper junction with the Ti alloy acetabular shell. Scanning electron microscopy indicated the primary mechanism of corrosion to be grain boundary and associated crevice corrosion, which was likely accelerated through mechanical micromotion and galvanic corrosion resulting from dissimilar alloys. Coordinate measurements revealed up to 4.3mm(3) of the cobalt-chromium alloy taper surface was removed due to corrosion, which is comparable to previous reports of corrosion damage on head-neck tapers. The acetabular liner-shell taper appears to be an additional source of metal corrosion products in modular total hip replacements. Patients with these prostheses should be closely monitored for signs of adverse reaction towards corrosion by-products. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Near-field fluorescence thermometry using highly efficient triple-tapered near-field optical fiber probe.

    PubMed

    Fujii, T; Taguchi, Y; Saiki, T; Nagasaka, Y

    2012-12-01

    A novel local temperature measurement method using fluorescence near-field optics thermal nanoscopy (Fluor-NOTN) has been developed. Fluor-NOTN enables nanoscale temperature measurement in situ by detecting the temperature-dependent fluorescence lifetime of CdSe quantum dots (QDs). In this paper, we report a novel triple-tapered near-field optical fiber probe that can increase the temperature measurement sensitivity of Fluor-NOTN. The performance of the proposed probe was numerically evaluated by the finite difference time domain method. Due to improvements in both the throughput and collection efficiency of near-field light, the sensitivity of the proposed probe was 1.9 times greater than that of typical double-tapered probe. The proposed shape of the triple-tapered core was successfully fabricated utilizing a geometrical model. The detected signal intensity of dried layers of QDs was greater by more than two orders than that of auto-fluorescence from the fiber core. In addition, the near-field fluorescence lifetime of the QDs and its temperature dependence were successfully measured by the fabricated triple-tapered near-field optical fiber probe. These measurement results verified the capability of the proposed triple-tapered near-field optical fiber probe to improve the collection efficiency of near-field fluorescence.

  13. Compatible taper equation for loblolly pine

    Treesearch

    J. P. McClure; R. L. Czaplewski

    1986-01-01

    Cao's compatible, segmented polynomial taper equation (Q. V. Cao, H. E. Burkhart, and T. A. Max. For. Sci. 26: 71-80. 1980) is fitted to a large loblolly pine data set from the southeastern United States. Equations are presented that predict diameter at a given height, height to a given top diameter, and volume below a given position on the main stem. All...

  14. Endocrine Dysfunction and Slipped Capital Femoral Epiphysis 1

    PubMed Central

    Ogden, John A.; Southwick, Wayne O.

    1977-01-01

    Five patients with concomitant endocrinopathy and slipped capital femoral epiphysis were studied in detail. One had diabetes and hypothyroidism, one had hypothyroidism, one had hypergonadotropic hypogonadism and two had a craniopharyngioma (one of whom had severe panhypopituitarism post-operatively). An additional seven patients with cranio-pharyngioma revealed marked delay in closure of epiphyses and an additional undiagnosed case of slipped capital femoral epiphysis. Of the six patients with slipped capital femoral epiphysis, three had bilateral and three unilateral involvement. Of the five patients undergoing surgical stabilization, there was significant delay of epiphyseodesis, prompting us to recommend concomitant bone grafting. Histological examination of the femoral head from a three year old child with panhypopituitarism showed marked irregularity of the growth plate and loss of columnar integrity, which may be a predisposing factor to slipping in older children with endocrinopathies. The effects of various hormones on the physis are specifically discussed, especially as they relate to the possible etiology of slipped capital femoral epiphysis. ImagesFIG. 1A and 1BFIG. 2FIG. 3A and 3BFIG. 4A and 4BFIG. 5 PMID:191998

  15. Synthesis of Titanium Oxycarbide from Titanium Slag by Methane-Containing Gas

    NASA Astrophysics Data System (ADS)

    Dang, Jie; Fatollahi-Fard, Farzin; Pistorius, Petrus Christiaan; Chou, Kuo-Chih

    2018-02-01

    In this study, reaction steps of a process for synthesis of titanium oxycarbide from titanium slag were demonstrated. This process involves the reduction of titanium slag by a methane-hydrogen-argon mixture at 1473 K (1200 °C) and the leaching of the reduced products by hydrofluoric acid near room temperature to remove the main impurity (Fe3Si). Some iron was formed by disproportionation of the main M3O5 phase before gaseous reduction started. Upon reduction, more iron formed first, followed by reduction of titanium dioxide to suboxides and eventually oxycarbide.

  16. Removal of titanium plates coated with anodic titanium oxide ceramic: retrospective study.

    PubMed

    Velich, Norbert; Németh, Zsolt; Suba, Csongor; Szabó, György

    2002-09-01

    Transformation of the surface of metallic titanium with titanium oxides prepared in various ways is a modern procedure. For more than 15 years, the authors have been utilizing fixing elements coated with titanium oxide ceramics, prepared by anodic oxidation and thermal treatment, for purposes of jawbone osteosynthesis. The aim of the authors' work was to assess the extent to which the titanium oxide ceramic coating influences the fate of the plates used for osteosynthesis within the human organism, in regard to the possible need for their removal. During a 5-year period, 108 of 1,396 plates coated with anodic titanium oxide had to be removed for various reasons: plate exposure (47), osteomyelitis (25), palpable swelling and tenderness (21), patient request for psychological reasons (13), or fracture of the plate (2). In none of these 108 cases was metallosis observed, which otherwise is reported relatively frequently in the vicinity of traditional titanium fixing elements, nor was any tissue damage connected with the surface of the plates. The results indicate the favorable properties of the titanium oxide ceramic surface.

  17. Using Ultrasound to Enhance Medical Students' Femoral Vascular Physical Examination Skills.

    PubMed

    Ahn, Justin S; French, Andrew J; Thiessen, Molly E W; Browne, Vaughn; Deutchman, Mark; Guiton, Gretchen; Madigosky, Wendy; Kendall, John L

    2015-10-01

    To determine whether the addition of ultrasound to traditional physical examination instruction improves junior medical students' abilities to locate the femoral pulse. Initially, 150 second-year medical students were taught the femoral pulse examination using traditional bedside teaching on standardized patients and online didactic videos. Students were then randomized into 2 groups: group 1 received ultrasound training first and then completed the standardized examination; and group 2 performed the standardized examination first and then received ultrasound training. On the standardized patients, the femoral artery was marked with invisible ink before the sessions using ultrasound. Compared to these markers, students were then evaluated on the accuracy of femoral artery pulse palpation and the estimated location of the femoral vein. All students completed a self-assessment survey after the ultrasound sessions. Ultrasound training improved the students' ability to palpate the femoral pulse (P= .02). However, ultrasound did not facilitate correct estimation of the femoral vein's anatomic location (P = .09). Confidence levels in localizing the femoral artery and vein were equal between groups at baseline, and both increased after the ultrasound sessions. The addition of ultrasound teaching to traditional physical examination instruction enhanced medical student competency and confidence with the femoral vascular examination. However, understanding of anatomy may require emphasis on precourse didactic material, but further study is required. © 2015 by the American Institute of Ultrasound in Medicine.

  18. Artificial Intelligence Procedures for Tree Taper Estimation within a Complex Vegetation Mosaic in Brazil

    PubMed Central

    Nunes, Matheus Henrique

    2016-01-01

    Tree stem form in native tropical forests is very irregular, posing a challenge to establishing taper equations that can accurately predict the diameter at any height along the stem and subsequently merchantable volume. Artificial intelligence approaches can be useful techniques in minimizing estimation errors within complex variations of vegetation. We evaluated the performance of Random Forest® regression tree and Artificial Neural Network procedures in modelling stem taper. Diameters and volume outside bark were compared to a traditional taper-based equation across a tropical Brazilian savanna, a seasonal semi-deciduous forest and a rainforest. Neural network models were found to be more accurate than the traditional taper equation. Random forest showed trends in the residuals from the diameter prediction and provided the least precise and accurate estimations for all forest types. This study provides insights into the superiority of a neural network, which provided advantages regarding the handling of local effects. PMID:27187074

  19. Effects of Multiple Drilling on the Ischemic Capital Femoral Epiphysis of Immature Piglets

    PubMed Central

    Gong, Sun Young; Kim, Hyun Woo; Park, Hui-Wan; Lee, Seung Yup

    2011-01-01

    Purpose This study investigated the effects of multiple drilling on the immature capital femoral epiphysis following ischemic injury in a piglet model. Materials and Methods Ischemic necrosis of capital femoral epiphysis was induced bilaterally in 12 piglets using a cervical ligation method. Three weeks later, medial, central, and lateral 3 drill holes were made on the left femoral head using 0.062" K-wire. At 3, 6, 9, and 12 weeks following the multiple drilling, femoral heads were harvested from each three piglets. On histologic examination, percent of revascularization, percent of osteoblast surface, capital femoral epiphyseal quotient and proximal femoral growth plate height were evaluated. Untreated right femoral heads served as control. Results While percent of revascularization of left capital femoral epiphysis with multiple drilling was significantly higher than untreated control side (p<0.001), percent of osteoblast surface, capital femoral epiphyseal quotient and proximal femoral growth plate height showed no significant difference. Conclusion This study indicates that multiple drilling could promote revascularization of ischemic capital femoral epiphysis, and multiple drilling does not appear to produce bony physeal bars at short-term, if using small diameter drill. However, multiple drilling alone does not seem to prevent femoral head deformity or to promote new bone formation. PMID:21786447

  20. Assessment of osteoinduction using a porous hydroxyapatite coating prepared by micro-arc oxidation on a new titanium alloy.

    PubMed

    Jing, Wensen; Zhang, Minghua; Jin, Lei; Zhao, Jian; Gao, Qing; Ren, Min; Fan, Qingyu

    2015-12-01

    Surface modification and material improvement is now an important way to improve the osseointegration between bone and uncemented prothesis. The purpose of this study was to investigate the bone ingrowth potential of porous hydroxyapatite (HA) coatings prepared by micro-arc oxidation (MAO) on Ti-3Zr-2Sn-3Mo-25Nb, a new titanium alloy. HA-coated specimens were implanted in the left proximal femoral medullary canal of beagles for 4, 12, and 24 weeks, and uncoated specimens were implanted in the right as a control. The surface morphology and phase composition were investigated with environmental scanning electron microscopy and X-ray diffractometry. The bone ingrowth was assessed by histomorphometry. A pull-out test was performed to assess the mechanical performance of the bone-implant interface. A porous coating was well prepared on the new titanium alloy by using the MAO method. The bone-to-implant contact was significantly higher for the HA-coated group compared to that in the uncoated group. Mechanical tests showed that the HA-coated group had significantly higher maximum force at the bone-implant interface compared to the uncoated specimens. MAO is a suitable coating approach for this new titanium alloy. The HA coating prepared by this approach can significantly promote bone ingrowth and the mechanical performance of the bone-implant interface. Copyright © 2015. Published by Elsevier Ltd.

  1. 980 nm tapered lasers with photonic crystal structure for low vertical divergence

    NASA Astrophysics Data System (ADS)

    Ma, Xiaolong; Qu, Hongwei; Zhao, Pengchao; Liu, Yun; Zheng, Wanhua

    2016-10-01

    High power tapered lasers with nearly diffraction-limited beam quality have attracted much attention in numerous applications such as nonlinear frequency conversion, optical pumping of solid-state and fiber lasers, medical treatment and others. However, the large vertical divergence of conventional tapered lasers is a disadvantage, which makes beam shaping difficult and expensive in applications. Diode lasers with photonic crystal structure can achieve a large mode size and a narrow vertical divergence. In this paper, we present tapered lasers with photonic crystal structure emitting at 980 nm. The epitaxial layer is grown using metal organic chemical vapor deposition. The device has a total cavity length of 2 mm, which consists of a 400-um long ridge-waveguide section and a 1600-um long tapered section. The taper angle is 4°. An output power of 3.3 W is achieved with a peak conversion efficiency of 35% in pulsed mode. The threshold current is 240 mA and the slope efficiency is 0.78 W/A. In continuous wave mode, the output power is 2.87 W, which is limited by a suddenly failure resulting from catastrophic optical mirror damage. The far field divergences with full width at half maximum are 12.3° in the vertical direction and 2.9° in the lateral direction at 0.5 A. At high injection level the vertical divergence doesn't exceed 16°. Beam quality factor M2 is measured based on second moment definition in CW mode. High beam quality is demonstrated by M2 value of less than 2 in both vertical and lateral directions.

  2. Hydraulics of Iowa DOT slope-tapered pipe culverts

    DOT National Transportation Integrated Search

    2001-06-01

    This report updates the Iowa Department of Transportation design procedures for circular, slope-tapered concrete culverts. The current practice is to use the design coefficients for a square-edged, circular concrete culvert with a headwall that are f...

  3. Short-term femoral nerve complications following percutaneous transfemoral procedures.

    PubMed

    Jarosz, J M; McKeown, B; Reidy, J F

    1995-01-01

    To determine the prevalence of transient femoral nerve anesthesia following transfemoral angiographic procedures. Fifty-eight patients undergoing a variety of routine transfemoral procedures underwent a neurologic assessment within an hour of the procedure. Nine patients (16%) were found to have complete or partial deficits in the ipsilateral femoral nerve territory. All deficits were transient. Transient femoral nerve deficits are not uncommon following transfemoral procedures. With the advent of true outpatient vascular procedures (where the patient may walk away after only a 30-minutes recovery period following a transvenous intervention or after 60 minutes following arteriography), transient neurologic problems related to the infiltration of local anesthetic around the femoral artery assume real clinical importance.

  4. A Tapered Aluminium Microelectrode Array for Improvement of Dielectrophoresis-Based Particle Manipulation

    PubMed Central

    Buyong, Muhamad Ramdzan; Larki, Farhad; Faiz, Mohd Syafiq; Hamzah, Azrul Azlan; Yunas, Jumrail; Majlis, Burhanuddin Yeop

    2015-01-01

    In this work, the dielectrophoretic force (FDEP) response of Aluminium Microelectrode Arrays with tapered profile is investigated through experimental measurements and numerical simulations. A standard CMOS processing technique with a step for the formation of a tapered profile resist is implemented in the fabrication of Tapered Aluminium Microelectrode Arrays (TAMA). The FDEP is investigated through analysis of the Clausius-Mossotti factor (CMF) and cross-over frequency (fxo). The performance of TAMA with various side wall angles is compared to that of microelectrodes with a straight cut sidewall profile over a wide range of frequencies through FEM numerical simulations. Additionally, electric field measurement (EFM) is performed through scanning probe microscopy (SPM) in order to obtain the region of force focus in both platforms. Results showed that the tapered profile microelectrodes with angles between 60° and 70° produce the highest electric field gradient on the particles. Also, the region of the strongest electric field in TAMA is located at the bottom and top edge of microelectrode while the strongest electric field in microelectrodes with straight cut profile is found at the top corner of the microelectrode. The latter property of microelectrodes improves the probability of capturing/repelling the particles at the microelectrode’s side wall. PMID:25970255

  5. A tapered aluminium microelectrode array for improvement of dielectrophoresis-based particle manipulation.

    PubMed

    Buyong, Muhamad Ramdzan; Larki, Farhad; Faiz, Mohd Syafiq; Hamzah, Azrul Azlan; Yunas, Jumrail; Majlis, Burhanuddin Yeop

    2015-05-11

    In this work, the dielectrophoretic force (F(DEP)) response of Aluminium Microelectrode Arrays with tapered profile is investigated through experimental measurements and numerical simulations. A standard CMOS processing technique with a step for the formation of a tapered profile resist is implemented in the fabrication of Tapered Aluminium Microelectrode Arrays (TAMA). The F(DEP) is investigated through analysis of the Clausius-Mossotti factor (CMF) and cross-over frequency (f(xo)). The performance of TAMA with various side wall angles is compared to that of microelectrodes with a straight cut sidewall profile over a wide range of frequencies through FEM numerical simulations. Additionally, electric field measurement (EFM) is performed through scanning probe microscopy (SPM) in order to obtain the region of force focus in both platforms. Results showed that the tapered profile microelectrodes with angles between 60° and 70° produce the highest electric field gradient on the particles. Also, the region of the strongest electric field in TAMA is located at the bottom and top edge of microelectrode while the strongest electric field in microelectrodes with straight cut profile is found at the top corner of the microelectrode. The latter property of microelectrodes improves the probability of capturing/repelling the particles at the microelectrode's side wall.

  6. Piezoelectric energy harvester having planform-tapered interdigitated beams

    DOEpatents

    Kellogg, Rick A [Tijeras, NM; Sumali, Hartono [Albuquerque, NM

    2011-05-24

    Embodiments of energy harvesters have a plurality of piezoelectric planform-tapered, interdigitated cantilevered beams anchored to a common frame. The plurality of beams can be arranged as two or more sets of beams with each set sharing a common sense mass affixed to their free ends. Each set thus defined being capable of motion independent of any other set of beams. Each beam can comprise a unimorph or bimorph piezoelectric configuration bonded to a conductive or non-conductive supporting layer and provided with electrical contacts to the active piezoelectric elements for collecting strain induced charge (i.e. energy). The beams are planform tapered along the entirety or a portion of their length thereby increasing the effective stress level and power output of each piezoelectric element, and are interdigitated by sets to increase the power output per unit volume of a harvester thus produced.

  7. Femoral Access and Delivery of Continuous Renal Replacement Therapy Dose.

    PubMed

    Bellomo, Rinaldo; Mårtensson, Johan; Lo, Serigne; Kaukonen, Kirsi-Maija; Cass, Alan; Gallagher, Martin

    2016-01-01

    The study aims to describe the use of dialysis catheters in critically ill patients treated with continuous renal replacement therapy (CRRT) and to study the impact of femoral versus non-femoral access on CRRT dose. Statistical analysis and predictive modelling of data from the Randomized Evaluation of Normal vs. Augmented Level renal replacement therapy trial. The femoral vein was the first access site in 937 (67%) of 1,399 patients. These patients had higher Acute Physiology and Chronic Health Evaluation and Sequential Organ Failure Assessment scores (p = 0.009) and lower pH (p < 0.001) but similar mortality to patients with non-femoral access (44 vs. 45%; p = 0.63). Lower body weight was independently associated with femoral access placement (OR 0.97, 95% CI 0.96-0.98). Femoral access was associated with a 1.03% lower CRRT dose (p = 0.05), but a 4.20% higher dose was achieved with 13.5 Fr catheters (p = 0.03). Femoral access was preferred in lighter and sicker patients. Catheter gauge had greater impact than catheter site in CRRT dose delivery. Video Journal Club "Cappuccino with Claudio Ronco" at http://www.karger.com/?doi=439581. © 2015 S. Karger AG, Basel.

  8. Femoral neck shaft angle in men with fragility fractures.

    PubMed

    Tuck, S P; Rawlings, D J; Scane, A C; Pande, I; Summers, G D; Woolf, A D; Francis, R M

    2011-01-01

    Introduction. Femoral neck shaft angle (NSA) has been reported to be an independent predictor of hip fracture risk in men. We aimed to assess the role of NSA in UK men. Methods. The NSA was measured manually from the DXA scan printout in men with hip (62, 31 femoral neck and 31 trochanteric), symptomatic vertebral (91), and distal forearm (67) fractures and 389 age-matched control subjects. Age, height, weight, and BMD (g/cm(2): lumbar spine, femoral neck, and total femur) measurements were performed. Results. There was no significant difference in mean NSA between men with femoral neck and trochanteric hip fractures, so all further analyses of hip fractures utilised the combined data. There was no difference in NSA between those with hip fractures and those without (either using the combined data or analysing trochanteric and femoral neck shaft fractures separately), nor between fracture subjects as a whole and controls. Mean NSA was smaller in those with vertebral fractures (129.2° versus 131°: P = 0.001), but larger in those with distal forearm fractures (129.8° versus 128.5°: P = 0.01). Conclusions. The conflicting results suggest that femoral NSA is not an important determinant of hip fracture risk in UK men.

  9. Logistic regression analysis of factors associated with avascular necrosis of the femoral head following femoral neck fractures in middle-aged and elderly patients.

    PubMed

    Ai, Zi-Sheng; Gao, You-Shui; Sun, Yuan; Liu, Yue; Zhang, Chang-Qing; Jiang, Cheng-Hua

    2013-03-01

    Risk factors for femoral neck fracture-induced avascular necrosis of the femoral head have not been elucidated clearly in middle-aged and elderly patients. Moreover, the high incidence of screw removal in China and its effect on the fate of the involved femoral head require statistical methods to reflect their intrinsic relationship. Ninety-nine patients older than 45 years with femoral neck fracture were treated by internal fixation between May 1999 and April 2004. Descriptive analysis, interaction analysis between associated factors, single factor logistic regression, multivariate logistic regression, and detailed interaction analysis were employed to explore potential relationships among associated factors. Avascular necrosis of the femoral head was found in 15 cases (15.2 %). Age × the status of implants (removal vs. maintenance) and gender × the timing of reduction were interactive according to two-factor interactive analysis. Age, the displacement of fractures, the quality of reduction, and the status of implants were found to be significant factors in single factor logistic regression analysis. Age, age × the status of implants, and the quality of reduction were found to be significant factors in multivariate logistic regression analysis. In fine interaction analysis after multivariate logistic regression analysis, implant removal was the most important risk factor for avascular necrosis in 56-to-85-year-old patients, with a risk ratio of 26.00 (95 % CI = 3.076-219.747). The middle-aged and elderly have less incidence of avascular necrosis of the femoral head following femoral neck fractures treated by cannulated screws. The removal of cannulated screws can induce a significantly high incidence of avascular necrosis of the femoral head in elderly patients, while a high-quality reduction is helpful to reduce avascular necrosis.

  10. Trombo flutuante em veia femoral

    PubMed Central

    Bertanha, Matheus; Pimenta, Rafael Elias Farres; Brandão, Gustavo Muçouçah Sampaio; Sobreira, Marcone Lima; Moura, Regina; Jaldin, Rodrigo Gibin; de Camargo, Paula Angeleli Bueno; Yoshida, Winston Bonetti

    2017-01-01

    Resumo O trombo venoso flutuante em veia femoral é um tipo de trombo com alto potencial de embolização pulmonar. Entretanto, ainda é controversa a conduta mais apropriada nesses casos. Tratamentos clínicos com anticoagulantes ou fibrinolíticos e trombectomias abertas ou por meio de dispositivos endovasculares vêm sendo empregados ainda sem um critério de indicação bem definido. Apresentamos três casos clínicos de trombos flutuantes em veia femoral, de etiologias distintas, cujos tratamentos e respectivas evoluções serão discutidos. PMID:29930666

  11. 65-fs Yb-doped all-fiber laser using tapered fiber for nonlinearity and dispersion management.

    PubMed

    Yang, Peilong; Teng, Hao; Fang, Shaobo; Hu, Zhongqi; Chang, Guoqing; Wang, Junli; Wei, Zhiyi

    2018-04-15

    We implement an ultrafast Yb-doped all-fiber laser which incorporates tapered single-mode fibers for managing nonlinearity and dispersion. The tapered fiber placed in the oscillator cavity aims to broaden the optical spectrum of the intracavity pulse. At the oscillator output, we use another tapered fiber to perform pulse compression. The resulting 66.1-MHz Yb-doped all-fiber oscillator self-starts and generates 0.4-nJ, 65-fs pulses, which can serve as a compact and robust seed source for subsequent high-power, high-energy amplifiers.

  12. Displaced femoral neck fatigue fractures in military recruits.

    PubMed

    Pihlajamäki, Harri K; Ruohola, Juha-Petri; Kiuru, Martti J; Visuri, Tuomo I

    2006-09-01

    Displaced fatigue fractures of the femoral neck are uncommon, but they can lead to substantial patient morbidity. This study was performed to examine the incidence, long-term consequences, radiographic findings, risk factors, and complications associated with this fracture. Between 1975 and 1994, twenty-one military recruits sustained a displaced fatigue fracture of the femoral neck. Nineteen patients were followed for an average of eighteen years. Data regarding the population at risk, hospital records, initial and follow-up radiographs, and physical findings were analyzed. The impact of instructions from the Finnish Defense Forces, Department of Medical Services, provided in 1986 for prevention of femoral neck fatigue fractures was assessed. At our institution, the incidence of displaced fatigue fractures of the femoral neck was 5.3/100,000 service years from 1975 to 1986, prior to the introduction of the prevention regimen in 1986, and it was 2.3/100,000 service years (95% confidence interval, 0.11 to 1.31) from 1987 to 1994. The rate of Garden type-IV fractures decreased from 3.8 to 0/100,000 service years (95% confidence interval, 0 to 0.66) between the first and second time-periods. The detection of nondisplaced symptomatic fatigue fractures of the femoral neck increased from 15.5 to 53.2/100,000 service years (95% confidence interval, 2.27 to 5.21) between the two time-periods. Eighteen of the nineteen patients had had prodromal symptoms prior to the fracture displacement. Following fracture treatment, six patients had delayed union or nonunion of the fracture. Osteonecrosis of the femoral head developed in six patients and was significantly associated (p = 0.001) with shortening of the femoral neck. Severe osteoarthritis developed in eight patients. A displaced fatigue fracture of the femoral neck leads to long-term morbidity in a high percentage of patients. Most patients have prodromal symptoms, which provide an opportunity to prevent fracture

  13. TAPERED DEFINING SLOT

    DOEpatents

    Pressey, F.W.

    1959-09-01

    An improvement is reported in the shape and formation of the slot or opening in the collimating slot member which forms part of an ion source of the type wherein a vapor of the material to be ionized is bombarded by electrons in a magnetic field to strike an arc-producing ionization. The defining slot is formed so as to have a substantial taper away from the cathode, causing the electron bombardment from the cathode to be dispersed over a greater area reducing its temperature and at the same time bringing the principal concentration of heat from the electron bombardment nearer the anode side of the slot, thus reducing deterioration and prolonging the life of the slot member during operation.

  14. Compatible taper and volume equations for young longleaf pine plantations in southwest Georgia

    Treesearch

    Lichun Jiang; John R. Brooks; Alexander Clark

    2010-01-01

    Inside and outside bark taper equations as well as compatible cubic foot volume equations were developed from felled tree data selected from young longleaf pine plantations that are part of an existing growth and yield study located in the Flint River drainage of southwest Georgia. A Max-Burkhart taper model was selected as the basic model form due to the accuracy...

  15. Characteristics of a Linearly Tapered Slot Antenna (LTSA) Conformed Longitudinally Around a Cylinder

    NASA Technical Reports Server (NTRS)

    Jordan, Jennifer L.; Ponchak, George E.; Tavassolian, Negar; Tentzeris, Manos M.

    2007-01-01

    The family of tapered slot antennas (TSA s) is suitable for numerous applications. Their ease of fabrication, wide bandwidth, and high gain make them desirable for military and commercial systems. Fabrication on thin, flexible substrates allows the TSA to be conformed over a given body, such as an aircraft wing or a piece of clothing for wearable networks. Previously, a Double Exponentially Tapered Slot Antenna (DETSA) was conformed around an exponential curvature, which showed that the main beam skewed towards the direction of curvature. This paper presents a Linearly Tapered Slot Antenna (LTSA) conformed longitudinally around a cylinder. Measured and simulated radiation patterns and the direction of maximum H co-polarization (Hco) as a function of the cylinder radius are presented.

  16. Effects of taper and space settings of telescopic Ce-TZP/A crowns on retentive force and settling.

    PubMed

    Nakagawa, Shusuke; Torii, Katsunori; Tanaka, Masahiro

    2017-03-31

    The aim of this study was to investigate the effect of the taper and space setting of using Ce-TZP/A on retentive force and secondary crown settling. The taper were 2°, 4°, and 6°, and the space settings were 0 and 10 μm. The applied loads were 50 and 100 N. The taper had a significant effect on retentive force and settling at both loads (p<0.05). The space settings did not have a significant effect on retentive force or settling at either load (p<0.05). The taper of the telescopic crowns and the load affected the retentive force and the settling.

  17. Simulation on friction taper plug welding of AA6063-20Gr metal matrix composite

    NASA Astrophysics Data System (ADS)

    Hynes, N. Rajesh Jesudoss; Nithin, Abeyram M.

    2016-05-01

    Friction taper plug welding a variant of friction welding is useful in welding of similar and dissimilar materials. It could be used for joining of composites to metals in sophisticated aerospace applications. In the present work numerical simulation of friction taper plug welding process is carried out using finite element based software. Graphite reinforced AA6063 is modelled using the software ANSYS 15.0 and temperature distribution is predicted. Effect of friction time on temperature distribution is numerically investigated. When the friction time is increased to 30 seconds, the tapered part of plug gets detached and fills the hole in the AA6063 plate perfectly.

  18. Resurgence of catatonia following tapering or stoppage of lorazepam - A case series and implications.

    PubMed

    Ali, Syed Farooq; Gowda, Guru S; Jaisoorya, T S; Math, Suresh Bada

    2017-08-01

    The resurgence of catatonia following tapering of lorazepam is a common clinical phenomenon. However, there is limited evidence on the relationship between tapering method of lorazepam and resurgence of catatonic state. We report seven (0.6%) such patients who were found to have resurgence of catatonia. The mean age is 35.7 years; five of them had schizophrenia and other psychotic spectrum disorders. Five of them had resurgence within one week of stoppage, and three of them had multiple resurgences and required maintenance treatment with lorazepam. So gradual tapering and maintenance treatment with lorazepam might be effective in preventing resurgence of catatonia. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Tapered Microfluidic for Continuous Micro-Object Separation Based on Hydrodynamic Principle.

    PubMed

    Ahmad, Ida Laila; Ahmad, Mohd Ridzuan; Takeuchi, Masaru; Nakajima, Masahiro; Hasegawa, Yasuhisa

    2017-12-01

    Recent advances in microfluidic technologies have created a demand for a simple and efficient separation intended for various applications such as food industries, biological preparation, and medical diagnostic. In this paper, we report a tapered microfluidic device for passive continuous separation of microparticles by using hydrodynamic separation. By exploiting the hydrodynamic properties of the fluid flow and physical characteristics of micro particles, effective size based separation is demonstrated. The tapered microfluidic device has widening geometries with respect to specific taper angle which amplify the sedimentation effect experienced by particles of different sizes. A mixture of 3-μm and 10-μm polystyrene microbeads are successfully separated using 20° and 25° taper angles. The results obtained are in agreement with three-dimensional finite element simulation conducted using Abaqus 6.12. Moreover, the feasibility of this mechanism for biological separation is demonstrated by using polydisperse samples consists of 3-μm polystyrene microbeads and human epithelial cervical carcinoma (HeLa) cells. 98% of samples purity is recovered at outlet 1 and outlet 3 with flow rate of 0.5-3.0 μl/min. Our device is interesting despite adopting passive separation approach. This method enables straightforward, label-free, and continuous separation of multiparticles in a stand-alone device without the need for bulky apparatus. Therefore, this device may become an enabling technology for point of care diagnosis tools and may hold potential for micrototal analysis system applications.

  20. Large-aperture, tapered fiber-coupled, 10-kHz particle-image velocimetry.

    PubMed

    Hsu, Paul S; Roy, Sukesh; Jiang, Naibo; Gord, James R

    2013-02-11

    We demonstrate the design and implementation of a fiber-optic beam-delivery system using a large-aperture, tapered step-index fiber for high-speed particle-image velocimetry (PIV) in turbulent combustion flows. The tapered fiber in conjunction with a diffractive-optical-element (DOE) fiber-optic coupler significantly increases the damage threshold of the fiber, enabling fiber-optic beam delivery of sufficient nanosecond, 532-nm, laser pulse energy for high-speed PIV measurements. The fiber successfully transmits 1-kHz and 10-kHz laser pulses with energies of 5.3 mJ and 2 mJ, respectively, for more than 25 min without any indication of damage. It is experimentally demonstrated that the tapered fiber possesses the high coupling efficiency (~80%) and moderate beam quality for PIV. Additionally, the nearly uniform output-beam profile exiting the fiber is ideal for PIV applications. Comparative PIV measurements are made using a conventionally (bulk-optic) delivered light sheet, and a similar order of measurement accuracy is obtained with and without fiber coupling. Effective use of fiber-coupled, 10-kHz PIV is demonstrated for instantaneous 2D velocity-field measurements in turbulent reacting flows. Proof-of-concept measurements show significant promise for the performance of fiber-coupled, high-speed PIV using a tapered optical fiber in harsh laser-diagnostic environments such as those encountered in gas-turbine test beds and the cylinder of a combustion engine.

  1. A Compatible Stem Taper-Volume-Weight System For Intensively Managed Fast Growing Loblolly Pine

    Treesearch

    Yugia Zhang; Bruce E. Borders; Robert L Bailey

    2002-01-01

    eometry-oriented methodology yielded a compatible taper-volume-weight system of models whose parameters were estimated using data from intensively managed loblolly pine (Pinus taeda L.) plantations in the lower coastal plain of Georgia. Data analysis showed that fertilization has significantly reduced taper (inside and outside bark) on the upper...

  2. Trochanteric entry femoral nails yield better femoral version and lower revision rates-A large cohort multivariate regression analysis.

    PubMed

    Yoon, Richard S; Gage, Mark J; Galos, David K; Donegan, Derek J; Liporace, Frank A

    2017-06-01

    Intramedullary nailing (IMN) has become the standard of care for the treatment of most femoral shaft fractures. Different IMN options include trochanteric and piriformis entry as well as retrograde nails, which may result in varying degrees of femoral rotation. The objective of this study was to analyze postoperative femoral version between three types of nails and to delineate any significant differences in femoral version (DFV) and revision rates. Over a 10-year period, 417 patients underwent IMN of a diaphyseal femur fracture (AO/OTA 32A-C). Of these patients, 316 met inclusion criteria and obtained postoperative computed tomography (CT) scanograms to calculate femoral version and were thus included in the study. In this study, our main outcome measure was the difference in femoral version (DFV) between the uninjured limb and the injured limb. The effect of the following variables on DFV and revision rates were determined via univariate, multivariate, and ordinal regression analyses: gender, age, BMI, ethnicity, mechanism of injury, operative side, open fracture, and table type/position. Statistical significance was set at p<0.05. A total of 316 patients were included. Piriformis entry nails made up the majority (n=141), followed by retrograde (n=108), then trochanteric entry nails (n=67). Univariate regression analysis revealed that a lower BMI was significantly associated with a lower DFV (p=0.006). Controlling for possible covariables, multivariate analysis yielded a significantly lower DFV for trochanteric entry nails than piriformis or retrograde nails (7.9±6.10 vs. 9.5±7.4 vs. 9.4±7.8°, p<0.05). Using revision as an endpoint, trochanteric entry nails also had a significantly lower revision rate, even when controlling for all other variables (p<0.05). Comparative, objective comparisons between DFV between different nails based on entry point revealed that trochanteric nails had a significantly lower DFV and a lower revision rate, even after regression

  3. 77 FR 50716 - Tapered Roller Bearings From China

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-22

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-344 (Third Review)] Tapered Roller..., the United States International Trade Commission (Commission) determines, pursuant to section 751(c... notice in the Office of the Secretary, U.S. International Trade Commission, Washington, DC, and by...

  4. In vitro characterization of two different atmospheric plasma jet chemical functionalizations of titanium surfaces

    NASA Astrophysics Data System (ADS)

    Mussano, F.; Genova, T.; Verga Falzacappa, E.; Scopece, P.; Munaron, L.; Rivolo, P.; Mandracci, P.; Benedetti, A.; Carossa, S.; Patelli, A.

    2017-07-01

    Plasma surface activation and plasma polymers deposition are promising technologies capable to modulate biologically relevant surface features of biomaterials. The purpose of this study was to evaluate the biological effects of two different surface modifications, i.e. amine (NH2-Ti) and carboxylic/esteric (COOH/R-Ti) functionalities obtained from 3-aminopropyltriethoxysilane (3-APTES) and methylmethacrylate (MMA) precursors, respectively, through an atmospheric plasma jet RF-APPJ portable equipment. The coatings were characterized by Scanning Electron Microscopy, FT-IR spectroscopy, XPS and surface energy calculations. Stability in water and after UV sterilization were also verified. The pre-osteoblastic murine cell line MC3T3-E1 was used to perform the in-vitro tests. The treated samples showed a higher quantity of adsorbed proteins and improved osteoblast cells adhesion on the surfaces compared to the pristine titanium, in particular the COOH/R-Ti led to a nearly two-fold improvement. Cell proliferation on coated samples was initially (at 24 h) lower than on titanium control, while, at 48 h, COOH/R-Ti reached the proliferation rate of pristine titanium. Cells grown on NH2-Ti were more tapered and elongated in shape with lower areas than on COOH/R-Ti enriched surfaces. Finally, NH2-Ti significantly enhanced osteocalcin production, starting from 14 days, while COOH/R-Ti had this effect only from 21 days. Notably, NH2-Ti was more efficient than COOH/R-Ti at 21 days. The amine functionality elicited the most relevant osteogenic effect in terms of osteocalcin expression, thus establishing an interesting correlation between early cell morphology and later differentiation stages. Taken together, these data encourage the use of the functionalization procedures here reported in further studies.

  5. Establishment of a bilateral femoral large segmental bone defect mouse model potentially applicable to basic research in bone tissue engineering.

    PubMed

    Xing, Junchao; Jin, Huiyong; Hou, Tianyong; Chang, Zhengqi; Luo, Fei; Wang, Pinpin; Li, Zhiqiang; Xie, Zhao; Xu, Jianzhong

    2014-12-01

    To understand the cellular mechanism underlying bone defect healing in the context of tissue engineering, a reliable, reproducible, and standardized load-bearing large segmental bone defect model in small animals is indispensable. The aim of this study was to establish and evaluate a bilateral femoral defect model in mice. Donor mouse bone marrow mesenchymal stem cells (mBMSCs) were obtained from six mice (FVB/N) and incorporated into partially demineralized bone matrix scaffolds to construct tissue-engineered bones. In total, 36 GFP(+) mice were used for modeling. Titanium fixation plates with locking steel wires were attached to the femurs for stabilization, and 2-mm-long segmental bone defects were created in the bilateral femoral midshafts. The defects in the left and right femurs were transplanted with tissue-engineered bones and control scaffolds, respectively. The healing process was monitored by x-ray radiography, microcomputed tomography, and histology. The capacity of the transplanted mBMSCs to recruit host CD31(+) cells was investigated by immunofluorescence and real-time polymerase chain reaction. Postoperatively, no complication was observed, except that two mice died of unknown causes. Stable fixation of femurs and implants with full load bearing was achieved in all animals. The process of bone defect repair was significantly accelerated due to the introduction of mBMSCs. Moreover, the transplanted mBMSCs attracted more host CD31(+) endothelial progenitors into the grafts. The present study established a feasible, reproducible, and clinically relevant bilateral femoral large segmental bone defect mouse model. This model is potentially suitable for basic research in the field of bone tissue engineering. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Theoretical study of mode evolution in active long tapered multimode fiber.

    PubMed

    Shi, Chen; Wang, Xiaolin; Zhou, Pu; Xu, Xiaojun; Lu, Qisheng

    2016-08-22

    A concise and effective model based on coupled mode theory to describe mode evolution in long tapered active fiber is presented in this manuscript. The mode coupling due to variation of core radius and slight perturbation have been analyzed and local gain with transverse spatial hole burning (TSHB) effect, loss and curvature have been taken into consideration in our model. On the base of this model, the mode evolution behaviors under different factors have been numerically investigated. Our model and results can provide instructive suggestions when designing long tapered fiber based laser and amplifiers.

  7. Assessment of apical transportation caused by nickel-titanium rotary systems with full rotation and reciprocating movements using extracted teeth and resin blocks with simulated root canals: A comparative study.

    PubMed

    Alrahabi, M; Zafar, M S

    2018-06-01

    : We compared apical transportation in the WaveOne and ProTaper Next systems, which are rotary nickel-titanium systems with reciprocating and continuous rotation movements, respectively, using manual measurements obtained from resin blocks with simulated root canals and double digital radiographs of extracted teeth. : We used 30 resin blocks with simulated root canals and 30 extracted teeth for this study. The same endodontist performed root canal shaping using the WaveOne or ProTaper Next system. We assessed apical transportation by measuring the amounts (in mm) of material lost 1 mm from the apical foramen in the resin blocks and by using double digital radiography for the extracted teeth. Significant differences between groups were assessed using t-tests. P < 0.05 was considered statistically significant. : The amount of apical transportation differed significantly between the two systems when resin blocks were used for assessment (P < 0.05), but there were no significant differences when extracted teeth were used (P < 0.05). In the current study, there was no significant difference in apical transportation between natural teeth prepared using WaveOne and those prepared using ProTaper Next. However, significant differences were observed between the two systems with resin blocks. These findings indicate that the use of resin blocks is not an accurate method for apical transportation evaluation.

  8. Fiber Volume Fraction Influence on Fiber Compaction in Tapered Resin Injection Pultrusion Manufacturing

    NASA Astrophysics Data System (ADS)

    Masuram, N. B.; Roux, J. A.; Jeswani, A. L.

    2016-06-01

    Liquid resin is injected into the tapered injection chamber through the injection slots to completely wetout the fiber reinforcements in a resin injection pultrusion process. As the resin penetrates through the fibers, the resin also pushes the fibers away from the wall towards the centerline causing compaction of the fiber reinforcements. The fibers are squeezed together due to compaction, making resin penetration more difficult; thus higher resin injection pressures are required to effectively penetrate through the fibers and achieve complete wetout. Fiber volume fraction in the final pultruded composite is a key to decide the mechanical and/or chemical properties of the composite. If the fiber volume fraction is too high, more fibers are squeezed together creating a fiber lean region near the wall and fiber rich region away from the wall. Also, the design of the injection chamber significantly affects the minimum injection pressure required to completely wet the fibers. A tapered injection chamber is considered such that wetout occurs at lower injection pressures due to the taper angle of the injection chamber. In this study, the effect of fiber volume fraction on the fiber reinforcement compaction and complete fiber wetout for a tapered injection chamber is investigated.

  9. Cutting efficiency of four different rotary nickel: Titanium instruments

    PubMed Central

    Cecchin, Doglas; de Sousa-Neto, Manoel Damião; Pécora, Jesus Djalma; Gariba-Silva, Ricardo

    2011-01-01

    Aim: The aim of this study was to evaluate the cutting efficiency of rotary nickel-titanium (NiTi) instruments K3, NiTi Tee, Profile, and Quantec with taper size 04/25. Materials and Methods: The number of samples was 10 for each group (n = 10). The cutting efficiency was measured by the mass loss from each acrylic resin block after instrumentation of a simulated canal using the Crown-down technique. Results: The analysis of variance (ANOVA) showed that there was a statistically significant difference among the studied groups. The Tukey's test showed that the acrylic resin blocks prepared with instruments K3 (0.00369 ± 0.00022), NiTi Tee (0.00368 ± 0.00023), and Profile (0.00351 ± 0.00026) presented the greatest mass loss, showing no statistically significant difference among them (P < 0.05). The lowest mass loss was found in the blocks prepared with Quantec instruments (0.00311 ± 0.0003) (P < 0.05). Conclusions: It could be concluded that the K3, NiTi Tee, and Profile instruments presented a greater cutting efficiency than the Quantec instruments. PMID:21814349

  10. Double-clad fiber with a tapered end for confocal endomicroscopy

    PubMed Central

    Lemire-Renaud, Simon; Strupler, Mathias; Benboujja, Fouzi; Godbout, Nicolas; Boudoux, Caroline

    2011-01-01

    We present a double-clad fiber coupler (DCFC) for use in confocal endomicroscopy to reduce speckle contrast, increase signal collection while preserving optical sectioning. The DCFC is made by incorporating a double-clad tapered fiber (DCTF) to a fused-tapered DCFC for achromatic transmission (from 1265 nm to 1325 nm) of > 95% illumination light trough the single mode (SM) core and collection of > 40% diffuse light through inner cladding modes. Its potential for confocal endomicroscopy is demonstrated in a spectrally-encoded imaging setup which shows a 3 times reduction in speckle contrast as well as 5.5 × increase in signal collection compared to imaging with a SM fiber. PMID:22076259

  11. Double-clad fiber with a tapered end for confocal endomicroscopy.

    PubMed

    Lemire-Renaud, Simon; Strupler, Mathias; Benboujja, Fouzi; Godbout, Nicolas; Boudoux, Caroline

    2011-11-01

    We present a double-clad fiber coupler (DCFC) for use in confocal endomicroscopy to reduce speckle contrast, increase signal collection while preserving optical sectioning. The DCFC is made by incorporating a double-clad tapered fiber (DCTF) to a fused-tapered DCFC for achromatic transmission (from 1265 nm to 1325 nm) of > 95% illumination light trough the single mode (SM) core and collection of > 40% diffuse light through inner cladding modes. Its potential for confocal endomicroscopy is demonstrated in a spectrally-encoded imaging setup which shows a 3 times reduction in speckle contrast as well as 5.5 × increase in signal collection compared to imaging with a SM fiber.

  12. Recovery of titanium values from titanium grinding swarf by electric furnace smelting

    DOEpatents

    Gerdemann, Stephen J.; White, Jack C.

    1999-01-01

    A method for the recovery of valuable materials from titanium grinding swarf is provided comprising the steps of sieving the accumulated titanium grinding swarf to remove unwanted coarse trash and grinding wheel fragments, pelletizing, and smelting in an electric arc furnace to produce ferrotitanium and/or high titanium slag.

  13. Recovery of titanium values from titanium grinding swarf by electric furnace smelting

    DOEpatents

    Gerdemann, Stephen J.; White, Jack C.

    1998-01-01

    A method for the recovery of valuable materials from titanium grinding swarf is provided comprising the steps of sieving the accumulated titanium grinding swarf to remove unwanted coarse trash and grinding wheel fragments, pelletizing, and smelting in an electric arc furnace to produce ferrotitanium and/or high titanium slag.

  14. Mode conversion in a tapered fiber via a whispering gallery mode resonator and its application as add/drop filter.

    PubMed

    Huang, Ligang; Wang, Jie; Peng, Weihua; Zhang, Wending; Bo, Fang; Yu, Xuanyi; Gao, Feng; Chang, Pengfa; Song, Xiaobo; Zhang, Guoquan; Xu, Jingjun

    2016-02-01

    Based on the conversion between the fundamental mode (LP01) and the higher-order mode (LP11) in a tapered fiber via a whispering gallery mode resonator, an add/drop filter was proposed and demonstrated experimentally, in which the resonator only interacted with one tapered fiber, rather than two tapered fibers as in conventional configurations. The filter gains advantages of easy alignment and low scattering loss over the other filters based on tapered fiber and resonator, and will be useful in application.

  15. Formation of Titanium Sulfide from Titanium Oxycarbonitride by CS2 Gas

    NASA Astrophysics Data System (ADS)

    Ahmadi, Eltefat; Yashima, Yuta; Suzuki, Ryosuke O.; Rezan, Sheikh Abdul

    2018-05-01

    Previously this group reported that a good quality titanium metal powder can be produced from titanium sulfides by electrochemical OS process. In this study, the sulfurization procedure was examined to synthesize titanium sulfide from titanium oxycarbonitride by CS2 gas. The experiments were carried out in the temperature range of 1173 K to 1523 K (900 °C to 1250 °C) in a tube reactor with continuously flowing argon (Ar) as carrier gas of CS2. The formation of titanium sulfide phases from the commercial TiN, TiC, and TiO powders was studied as the initial step. Then, TiO0.02C0.13N0.85 coming from ilmenite was sulfurized to prepare single phase of titanium sulfide. The products were characterized by X-ray diffraction, and the morphology of the sulfides was rigorously investigated, and the sulfur, oxygen, and carbon contents in the products were analyzed. The process was remarkably dependent on the temperature and time. TiN and TiO0.02C0.13N0.85 powders could be fully converted to the single phase of Ti2.45S4 (Ti2+x S4) at 1473 K (1200 °C) in 3.6 ks. The maximum weight gain of TiN sample was 55.3 pct indicating a full conversion of TiN to Ti2S3 phase. The carbon and oxygen contents in this sulfide prepared from the oxycarbonitride were about 1.8 wt pct C and 1.4 wt pct O, respectively. Therefore, the titanium sulfide could be a promising feedstock for the production of commercial grade titanium powder.

  16. Multipoint fiber-optic laser-ultrasonic actuator based on fiber core-opened tapers.

    PubMed

    Tian, Jiajun; Dong, Xiaolong; Gao, Shimin; Yao, Yong

    2017-11-27

    In this study, a novel fiber-optic, multipoint, laser-ultrasonic actuator based on fiber core-opened tapers (COTs) is proposed and demonstrated. The COTs were fabricated by splicing single-mode fibers using a standard fiber splicer. A COT can effectively couple part of a core mode into cladding modes, and the coupling ratio can be controlled by adjusting the taper length. Such characteristics are used to obtain a multipoint, laser-ultrasonic actuator with balanced signal strength by reasonably controlling the taper lengths of the COTs. As a prototype, we constructed an actuator that generated ultrasound at four points with a balanced ultrasonic strength by connecting four COTs with coupling ratios of 24.5%, 33.01%, 49.51%, and 87.8% in a fiber link. This simple-to-fabricate, multipoint, laser-ultrasonic actuator with balanced ultrasound signal strength has potential applications in fiber-optic ultrasound testing technology.

  17. Friction Stir Welding of Tapered Thickness Welds Using an Adjustable Pin Tool

    NASA Technical Reports Server (NTRS)

    Adams, Glynn; Venable, Richard; Lawless, Kirby

    2003-01-01

    Friction stir welding (FSW) can be used for joining weld lands that vary in thickness along the length of the weld. An adjustable pin tool mechanism can be used to accomplish this in a single-pass, full-penetration weld by providing for precise changes in the pin length relative to the shoulder face during the weld process. The difficulty with this approach is in accurately adjusting the pin length to provide a consistent penetration ligament throughout the weld. The weld technique, control system, and instrumentation must account for mechanical and thermal compliances of the tooling system to conduct tapered welds successfully. In this study, a combination of static and in-situ measurements, as well as active control, is used to locate the pin accurately and maintain the desired penetration ligament. Frictional forces at the pin/shoulder interface were a source of error that affected accurate pin position. A traditional FSW pin tool design that requires a lead angle was used to join butt weld configurations that included both constant thickness and tapered sections. The pitch axis of the tooling was fixed throughout the weld; therefore, the effective lead angle in the tapered sections was restricted to within the tolerances allowed by the pin tool design. The sensitivity of the FSW process to factors such as thickness offset, joint gap, centerline offset, and taper transition offset were also studied. The joint gap and the thickness offset demonstrated the most adverse affects on the weld quality. Two separate tooling configurations were used to conduct tapered thickness welds successfully. The weld configurations included sections in which the thickness decreased along the weld, as well as sections in which the thickness increased along the weld. The data presented here include weld metallography, strength data, and process load data.

  18. Osteoid Osteoma of the Femoral Neck in Athletes

    PubMed Central

    Cordova, Christopher B.; Dembowski, Scott C.; Johnson, Michael R.; Combs, John J.; Svoboda, Steven J.

    2015-01-01

    The diagnosis of an intra-articular osteoid osteoma can be a challenging and lengthy process, with reports of delayed diagnosis of greater than 2 years. In the young, athletic patient with an atraumatic onset of groin pain, an overuse injury or muscle strain is the most likely etiology. However, an overuse injury of femoral neck stress fracture must be identified because of the potentially disastrous outcome of fracture completion. The similar clinical presentation of a femoral neck stress fracture and intra-articular osteoid osteoma of the femoral neck can further delay the diagnosis of the osteoid osteoma. In a patient with these differential diagnoses that do not improve with a period of nonweightbearing activity, a more intensive workup must ensue. The purpose of this case report is to describe the initial presentations, subsequent follow-up, and imaging findings leading to the diagnosis of osteoid osteoma as well as to differentiate an osteoid osteoma from femoral neck stress injuries. PMID:26517936

  19. Recovery of titanium values from titanium grinding swarf by electric furnace smelting

    DOEpatents

    Gerdemann, S.J.; White, J.C.

    1998-08-04

    A method for the recovery of valuable materials from titanium grinding swarf is provided comprising the steps of sieving the accumulated titanium grinding swarf to remove unwanted coarse trash and grinding wheel fragments, pelletizing, and smelting in an electric arc furnace to produce ferrotitanium and/or high titanium slag. 1 fig.

  20. Reduced head-neck offset in nontraumatic osteonecrosis of the femoral head.

    PubMed

    Fraitzl, Christian R; Kappe, Thomas; Brugger, Annina; Billich, Christian; Reichel, Heiko

    2013-08-01

    Risk factors for nontraumatic osteonecrosis of the femoral head have in common that they trigger intravascular coagulation and thus lead to devascularization of the femoral head. In part of the patients, however, no risk factors seem to be evident. Mechanical reasons contributing to nontraumatic osteonecrosis have not been discussed so far. We hypothesized that recurrent traumatization of the vessels supplying the femoral head by a cam-type mechanism as in femoroacetabular impingement could add to intravascular coagulation. We, therefore, asked whether structural abnormalities at the femoral head-neck junction indicative of such a mechanism could be observed in radiographs of patients with osteonecrosis of the femoral head. The preoperative anteroposterior and lateral radiographs of 77 patients who underwent surgery because of osteonecrosis of the femoral head were retrospectively screened for a reduced head-neck offset by measuring the α-angle. For comparison, the α-angle was measured on anteroposterior and lateral radiographs of 339 control subjects without evident underlying hip pathology. The mean α-angle was 62.8° (SD 18.7°) for anteroposterior and 67.6° (SD 13.2°) for lateral radiographs in patients with nontraumatic osteonecrosis of the femoral head, whereas in control subjects, the mean α-angle was 47.2° (SD 9.6°) (p < 0.0001) and 47.6° (SD 10.3°) (p < 0.0001), respectively. A reduced head-neck offset in patients with nontraumatic osteonecrosis of the femoral head may act as a mechanical (co-)factor in developing osteonecrosis of the femoral head.

  1. Design of multiple-ply laminated composite tapered beams

    NASA Technical Reports Server (NTRS)

    Rodriguez, P.

    1993-01-01

    A study of a special case of symmetric laminated composite cantilever beams is presented. The approach models beams that are tapered both in depth and width and investigates the effect of the ply layup angle and the ply taper on bending and interlaminar shearing stresses. For the determination of stresses and deflections, the beam stiffness matrices are expressed as linear functions of the beam length. Using classical lamination theory (CLT) the stiffness matrices are determined and assembled at strategic locations along the length of the beam. They are then inverted and necessary stiffness parameters are obtained numerically and extracted for determination of design information at each location chosen. Several ply layup configurations are investigated, and design considerations are presented based on the findings. Finally, recommendations for the design of these beams are presented, and a means for anticipating the location of highest stresses is offered.

  2. Design of multiple-ply laminated composite tapered beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodriguez, P.

    1993-06-01

    A study of a special case of symmetric laminated composite cantilever beams is presented. The approach models beams that are tapered both in depth and width and investigates the effect of the ply layup angle and the ply taper on bending and interlaminar shearing stresses. For the determination of stresses and deflections, the beam stiffness matrices are expressed as linear functions of the beam length. Using classical lamination theory (CLT) the stiffness matrices are determined and assembled at strategic locations along the length of the beam. They are then inverted and necessary stiffness parameters are obtained numerically and extracted formore » determination of design information at each location chosen. Several ply layup configurations are investigated, and design considerations are preSDsented based on the findings. Finally, recommendations for the design of these beams are presented, and a means for anticipating the location of highest stresses is offered.« less

  3. Ten-Year Cross-Sectional Study of Mechanically Assisted Crevice Corrosion in 1352 Consecutive Patients With Metal-on-Polyethylene Total Hip Arthroplasty.

    PubMed

    Hussey, Daniel K; McGrory, Brian J

    2017-08-01

    Mechanically assisted crevice corrosion (MACC) in metal-on-polyethylene total hip arthroplasty (THA) is of concern, but its prevalence, etiology, and natural history are incompletely understood. From January 2003 to December 2012, 1352 consecutive THA surgeries using a titanium stem, cobalt-chromium alloy femoral head, and highly cross-linked polyethylene liner from a single manufacturer were performed. Patients were followed at 1-year and 5-year intervals for surveillance, but also seen earlier if they had symptoms. Any patient with osteolysis >1 cm (n = 3) or unexplained pain (n = 85) underwent examination, radiographs, complete blood count, erythrocyte sedimentation rate, and C-reactive protein, as well as tests for serum cobalt and chromium levels. Symptomatic MACC was present in 43 of 1352 patients (3.2%). Prevalence of MACC by year of implant ranged from 0% (0 of 61, 2003; 0 of 138, 2005) to 10.5% (17 of 162; 2009). The M/L Taper stem had a greater prevalence (4.9%) of MACC than all other Zimmer (Zimmer, Inc, Warsaw, IN) 12/14 trunnion stem types combined (1.2%; P < .001). Twenty-seven of 43 (62.8%) patients have undergone revision surgery, and 16 of 43 (37.2%) patients have opted for ongoing surveillance. Comparing symptomatic THA patients with and without MACC, no demographic, clinical, or radiographic differences were found. MACC was significantly more common in 0 length femoral heads (compared with both -3.5 mm and +3.5 mm heads). The prevalence of MACC in metal-on-polyethylene hips is higher in this cross-sectional study than previously reported. A significantly higher prevalence was found in patients with M/L Taper style stem and THA performed both in 2009 and also between 2009 and 2012 with this manufacturer. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. 77 FR 12326 - Tapered Roller Bearings From China; Scheduling of a Full Five-Year Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-29

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-344 (Third Review)] Tapered Roller Bearings From China; Scheduling of a Full Five- Year Review AGENCY: United States International Trade... whether revocation of the antidumping duty order on tapered roller bearings from China would be likely to...

  5. Vector rectangular-shape laser based on reduced graphene oxide interacting with a long fiber taper.

    PubMed

    Gao, Lei; Zhu, Tao; Huang, Wei; Zeng, Jing

    2014-10-01

    A vector dual-wavelength rectangular-shape laser (RSL) based on a long fiber taper deposited with reduced graphene oxide is proposed, where nonlinearity is enhanced due to a large evanescent-field-interacting length and strong field confinement of an 8 mm fiber taper with a waist diameter of 4 μm. Graphene flakes are deposited uniformly on the taper waist with light pressure effect, so this structure guarantees both excellent saturable absorption and high nonlinearity. The RSL with a repetition rate of 7.9 MHz shows fast polarization switching in two orthogonal polarization directions, and temporal and spectral characteristics are investigated.

  6. Contact damage failure analyses of fretting wear behavior of the metal stem titanium alloy-bone cement interface.

    PubMed

    Zhang, Lanfeng; Ge, Shirong; Liu, Hongtao; Wang, Qingliang; Wang, Liping; Xian, Cory J

    2015-11-01

    Although cemented titanium alloy is not favored currently in the Western world for its poor clinical and radiography outcomes, its lower modulus of elasticity and good biocompatibility are instrumental for its ability supporting and transforming physical load, and it is more suitable for usage in Chinese and Japanese populations due to their lower body weights and unique femoral characteristics. Through various friction tests of different cycles, loads and conditions and by examining fretting hysteresis loops, fatigue process curves and wear surfaces, the current study investigated fretting wear characteristics and wear mechanism of titanium alloy stem-bone cement interface. It was found that the combination of loads and displacement affected the wear quantity. Friction coefficient, which was in an inverse relationship to load under the same amplitude, was proportional to amplitudes under the same load. Additionally, calf serum was found to both lubricate and erode the wear interface. Moreover, cement fatigue contact areas appeared black/oxidative in dry and gruel in 25% calf serum. Fatigue scratches were detected within contact areas, and wear scars were found on cement and titanium surfaces, which were concave-shaped and ring concave/ convex-shaped, respectively. The coupling of thermoplastic effect and minimal torque damage has been proposed to be the major reason of contact damage. These data will be important for further studies analyzing metal-cement interface failure performance and solving interface friction and wear debris production issues. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Effectiveness of supplementary irrigant agitation with the Finisher GF Brush on the debridement of oval root canals instrumented with the Gentlefile or nickel titanium rotary instruments.

    PubMed

    Neelakantan, P; Khan, K; Li, K Y; Shetty, H; Xi, W

    2018-07-01

    To examine the efficacy of a novel supplementary irrigant agitating brush (Finisher GF Brush, MedicNRG, Kibbutz Afikim, Israel) on the debridement of root canals prepared with a novel stainless steel rotary instrumentation system (Gentlefile; MedicNRG), or nickel titanium rotary instruments in oval root canals. Mandibular premolars (n = 72) were selected and divided randomly into three experimental groups (n = 24) after microCT scanning: group 1, canal preparation to rotary NiTi size 20, .04 taper (R20); group 2, rotary NiTi to size 25, .04 taper (R25) and group 3, Gentlefile size 23, .04 taper (GF). Specimens were subdivided into two subgroups: subgroup A, syringe-and-needle irrigation (SNI); subgroup B, Finisher GF Brush (GB). Ten untreated canals served as controls. Specimens were processed for histological evaluation, and the remaining pulp tissue (RPT) was measured. Data were analysed using Mann-Whitney and Kruskal-Wallis tests (P = 0.05). All experimental groups had significantly less RPT than the control (P < 0.05). Group 3B (GF-GB) had significantly less RPT than groups 1B (R20-GB) and 2B (R25-GF; P < 0.05). When irrigated with SNI, there was no significant difference in the RPT between the three groups (P > 0.05). When instrumented with R20, there was no significant difference between SNI and GF (P < 0.05) whilst GB had significantly less RPT than SNI for R25 (P < 0.05). Supplementary irrigant agitation with the Finisher GF Brush improved the debridement of canals prepared with Gentlefile and size 25, .04 taper rotary NiTi. Root canal debridement did not significantly differ between the instruments when syringe irrigation was used. © 2018 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  8. [The influence of autoclave sterilization on surface characteristics and cyclic fatigue resistance of 3 nickel-titanium rotary instruments].

    PubMed

    Li, Xiang-fen; Zheng, Ping; Xu, Li; Su, Qin

    2015-12-01

    To investigate the effects of autoclave sterilization on surface characteristics and cyclic fatigue resistance of 3 types of nickel-titanium rotary instruments (K3, Mtwo, ProTaper). Three brands of NiTi rotary endodontic instruments of the same size (tip diameter 0.25 mm and constant 0.06 taper) were selected: K3, Mtwo and Protaper (F2). 24 instruments for each brand were used to evaluate the effects of autoclave sterilization on inner character in the as-received condition and after subjection to 0, 1, 5, and 10 sterilization cycles (6 for each group). Time to fracture (TtF) from the start of the test to the moment of file breakage and the length of the fractured fragment were recorded. Means and standard deviations of TtF and fragment length were calculated. The data was analyzed with SPSS13.0 software package. Another 12 NiTi rotary instruments for each brand were used, 6 subjected to 10 autoclave sterilization cycles and the other as control. Scanning electron microscope was used to observe the changes in surface topography and inner character. For cyclic fatigue resistance, when sterilization was not performed, K3 showed the highest value of TtF means and ProTaper the lowest. The differences between each brand were statistically significant (P<0.05).When disinfection was performed, K3 brand showed greater fatigue resistance in comparison with the control when autoclave sterilization cycled 5 times and 10 times. The difference between 10 cycles of sterilization and the control was statistically significant (P<0.05); ProTaper brand showed significantly greater fatigue resistance in all the disinfected groups compared with the control (P<0.05) and 5 cycles of sterilization led to the greatest increment; The fatigue resistance of Mtwo brands increased with sterilization cycles and the difference between 5/10 cycles and the control were statistically significant (P<0.05). For surface characteristics, under scanning electron microscope, surface and inner

  9. Effect of platform connection and abutment material on stress distribution in single anterior implant-supported restorations: a nonlinear 3-dimensional finite element analysis.

    PubMed

    Carvalho, Marco Aurélio; Sotto-Maior, Bruno Salles; Del Bel Cury, Altair Antoninha; Pessanha Henriques, Guilherme Elias

    2014-11-01

    Although various abutment connections and materials have recently been introduced, insufficient data exist regarding the effect of stress distribution on their mechanical performance. The purpose of this study was to investigate the effect of different abutment materials and platform connections on stress distribution in single anterior implant-supported restorations with the finite element method. Nine experimental groups were modeled from the combination of 3 platform connections (external hexagon, internal hexagon, and Morse tapered) and 3 abutment materials (titanium, zirconia, and hybrid) as follows: external hexagon-titanium, external hexagon-zirconia, external hexagon-hybrid, internal hexagon-titanium, internal hexagon-zirconia, internal hexagon-hybrid, Morse tapered-titanium, Morse tapered-zirconia, and Morse tapered-hybrid. Finite element models consisted of a 4×13-mm implant, anatomic abutment, and lithium disilicate central incisor crown cemented over the abutment. The 49 N occlusal loading was applied in 6 steps to simulate the incisal guidance. Equivalent von Mises stress (σvM) was used for both the qualitative and quantitative evaluation of the implant and abutment in all the groups and the maximum (σmax) and minimum (σmin) principal stresses for the numerical comparison of the zirconia parts. The highest abutment σvM occurred in the Morse-tapered groups and the lowest in the external hexagon-hybrid, internal hexagon-titanium, and internal hexagon-hybrid groups. The σmax and σmin values were lower in the hybrid groups than in the zirconia groups. The stress distribution concentrated in the abutment-implant interface in all the groups, regardless of the platform connection or abutment material. The platform connection influenced the stress on abutments more than the abutment material. The stress values for implants were similar among different platform connections, but greater stress concentrations were observed in internal connections

  10. [Femoral arteriovenous fistula: a late uncommon complication of central venous catheterization].

    PubMed

    Conz, P A; Malagoli, A; Normanno, M; Munaro, D

    2007-01-01

    A 77-year-old woman was admitted due to AV graft thrombosis; given the technical impossibility of performing other native AV fistulas, we chose to insert a tunnelled central venous catheter. Considering the vascular history of the patient, the central venous catheter could not be placed into the internal jugular vein; it was therefore put into the left femoral vein. Following a 3-month-period of the catheter working properly, the patient was hospitalized due to sudden acute pain in the left thigh. In a few days the patient developed an important haematoma with serious anemization in the left lower limb. Ultrasonography showed the presence of a fistula between the left common femoral artery and the femoral vein, leading to the subsequent successful positioning of a stent into the common femoral artery through right trans-femoral access. Angiography examination showed the femoral vein patency along the proximal stretch with respect to the function of the tunnelled venous catheter.

  11. Performance assessment of femoral knee components made from cobalt-chromium alloy and oxidized zirconium.

    PubMed

    Brandt, J-M; Guenther, L; O'Brien, S; Vecherya, A; Turgeon, T R; Bohm, E R

    2013-12-01

    The surface characteristics of the femoral component affect polyethylene wear in modular total knee replacements. In the present retrieval study, the surface characteristics of cobalt-chromium (CoCr) alloy and oxidized zirconium (OxZr) femoral components were assessed and compared. Twenty-six retrieved CoCr alloy femoral components were matched with twenty-six retrieved OxZr femoral components for implantation period, body-mass index, patient gender, implant type, and polyethylene insert thickness. The surface damage on the retrieved femoral components was evaluated using a semi-quantitative assessment method, scanning electron microscopy, and contact profilometry. The retrieved CoCr alloy femoral components showed less posterior surface gouging than OxZr femoral components; however, at a higher magnification, the grooving damage features on the retrieved CoCr alloy femoral components confirmed an abrasive wear mechanism. The surface roughness values Rp, Rpm, and Rpk for the retrieved CoCr alloy femoral components were found to be significantly higher than those of the retrieved OxZr femoral components (p≤0.031). The surface roughness values were higher on the medial condyles than on the lateral condyles of the retrieved CoCr alloy femoral components; such a difference was not observed on the retrieved OxZr femoral components. The surface roughness of CoCr alloy femoral components increased while the surface roughness of the OxZr femoral components remained unchanged after in vivo service. Therefore, the OxZr femoral components' resistance to abrasive wear may enable lower polyethylene wear and ensure long-term durability in vivo. Level IV. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  12. Mechanical aspects of degree of cement bonding and implant wedge effect.

    PubMed

    Yoon, Yong-San; Oxland, Thomas R; Hodgson, Antony J; Duncan, Clive P; Masri, Bassam A; Choi, Donok

    2008-11-01

    The degree of bonding between the femoral stem and cement in total hip replacement remains controversial. Our objective was to determine the wedge effect by debonding and stem taper angle on the structural behavior of axisymmetric stem-cement-bone cylinder models. Stainless steel tapered plugs with a rough (i.e. bonded) or smooth (i.e. debonded) surface finish were used to emulate the femoral stem. Three different stem taper angles (5 degrees , 7.5 degrees , 10 degrees ) were used for the debonded constructs. Non-tapered and tapered (7.5 degrees ) aluminum cylindrical shells were used to emulate the diaphyseal and metaphyseal segments of the femur. The cement-aluminum cylinder interface was designed to have a shear strength that simulated bone-cement interfaces ( approximately 8MPa). The test involved applying axial compression at a rate of 0.02mm/s until failure. Six specimens were tested for each combination of the variables. Finite element analysis was used to enhance the understanding of the wedge effect. The debonded stems sustained about twice as much load as the bonded stem, regardless of taper angle. The metaphyseal model carried 35-50% greater loads than the diaphyseal models and the stem taper produced significant differences. Based on the finite element analysis, failure was most probably by shear at the cement-bone interface. Our results in this simplified model suggest that smooth (i.e. debonded) stems have greater failure loads and will incur less slippage or shear failure at the cement-bone interface than rough (i.e. bonded) stems.

  13. Scale-Up of a Titanium Carbonitride Coating System for Titanium Alloys.

    DTIC Science & Technology

    1980-07-01

    Ti-Cote C on JT12 Compressor 7th-Stage Airfoil -Optical Photomicrograph Porosity in Ti-Cote C Titanium 6AI- 4V Substrate - -- Mag: 1000OX FD 171506...30 21 TiCN Coating on Titanium 6A1- 4V ...indication of any corrosive damage to the titanium 6A1- 4V . This had been a matter of concern due to the corrosive nature of the reactive gases and

  14. Balloon-like singlemode-tapered multimode-singlemode fiber structure for refractive index sensing

    NASA Astrophysics Data System (ADS)

    Yang, Biyao; Niu, Yanxiong; Yang, Bowen; Dai, Lingling; Hu, Yanhui; Yin, Yiheng; Ding, Ming

    2017-10-01

    A novel high sensitivity refractive index sensor based on balloon-like singlemode-tapered multimode-singlemode (STMS) fiber structure has been proposed and experimentally demonstrated. Combining the tapering and bending endows the proposed sensor with large evanescent field, resulting in high sensitivity. Experimental results show that the proposed sensor has an average sensitivity of 1104.75 nm/RIU (RI Unit) in the range of 1.33-1.41 and a maximum sensitivity of 3374.50 nm/RIU at RI of 1.41.

  15. Dynamic illumination of spatially restricted or large brain volumes via a single tapered optical fiber

    PubMed Central

    Pisanello, Marco; Oldenburg, Ian A.; Sileo, Leonardo; Markowitz, Jeffrey E.; Peterson, Ralph E.; Della Patria, Andrea; Haynes, Trevor M.; Emara, Mohamed S.; Spagnolo, Barbara; Datta, Sandeep Robert; De Vittorio, Massimo; Sabatini, Bernardo L.

    2017-01-01

    Optogenetics promises spatiotemporal precise control of neural processes using light. However, the spatial extent of illumination within the brain is difficult to control and cannot be adjusted using standard fiber optics. We demonstrate that optical fibers with tapered tips can be used to illuminate either spatially restricted or large brain volumes. Remotely adjusting the light input angle to the fiber varies the light-emitting portion of the taper over several millimeters without movement of the implant. We use this mode to activate dorsal versus ventral striatum of individual mice and reveal different effects of each manipulation on motor behavior. Conversely, injecting light over the full numerical aperture of the fiber results in light emission from the entire taper surface, achieving broader and more efficient optogenetic activation of neurons when compared to the standard flat-faced fiber stimulation. Thus, tapered fibers permit focal or broad illumination that can be precisely and dynamically matched to experimental needs. PMID:28628101

  16. Dynamic illumination of spatially restricted or large brain volumes via a single tapered optical fiber.

    PubMed

    Pisanello, Ferruccio; Mandelbaum, Gil; Pisanello, Marco; Oldenburg, Ian A; Sileo, Leonardo; Markowitz, Jeffrey E; Peterson, Ralph E; Della Patria, Andrea; Haynes, Trevor M; Emara, Mohamed S; Spagnolo, Barbara; Datta, Sandeep Robert; De Vittorio, Massimo; Sabatini, Bernardo L

    2017-08-01

    Optogenetics promises precise spatiotemporal control of neural processes using light. However, the spatial extent of illumination within the brain is difficult to control and cannot be adjusted using standard fiber optics. We demonstrate that optical fibers with tapered tips can be used to illuminate either spatially restricted or large brain volumes. Remotely adjusting the light input angle to the fiber varies the light-emitting portion of the taper over several millimeters without movement of the implant. We use this mode to activate dorsal versus ventral striatum of individual mice and reveal different effects of each manipulation on motor behavior. Conversely, injecting light over the full numerical aperture of the fiber results in light emission from the entire taper surface, achieving broader and more efficient optogenetic activation of neurons, compared to standard flat-faced fiber stimulation. Thus, tapered fibers permit focal or broad illumination that can be precisely and dynamically matched to experimental needs.

  17. Improved vibration sensor based on a biconical tapered singlemode fiber, using in-fiber Mach-Zehnder interferometer

    NASA Astrophysics Data System (ADS)

    Wonko, R.; Moś, J. E.; Stasiewicz, K. A.; Jaroszewicz, L. R.

    2017-05-01

    Optical fiber vibration sensors are an appropriate alternative for piezoelectric devices, which are electromagnetic sensitive to the external conditions. Most of the vibration sensors demonstrated in previous publications resist to different interferometers or Bragg's gratings. Such sensors require a long time of stabilization of an optical signal, because they are vulnerable to undesirable disturbance. In majority, time response of an optical sensor should be instantaneous, therefore we have proposed an in- line vibration sensing passive element based on a tapered fiber. Micrometer sized optical fiber tapers are attractive for many optical areas due to changes process of boundary conditions. Such phenomena allow for a sensitive detection of the modulation phase. Our experiment shows that a singlemode, adiabatic tapered fiber enables detecting an acoustic vibration. In this study, we report on Mach- Zehnder (MZ) interferometer as a vibration sensor which was composed of two 50/50 couplers at 1550 nm. In the reference arm we used a 4 meter singlemode optical fiber (SMF28), while in the arm under test we placed tapered optical fibers attached to a metal plate, put directly on speaker. Researches carried out on different tapered fibers which diameter of a taper waist was in the range from 5 μm to 25 μm, and each taper was characterized by optical losses less than 0,5 dB. The measured phase changes were over a frequency from 100 Hz to 1 kHz and an amplitude in the range from 100 mVpp to 1 Vpp. Although on account of a limited space we have showed only the results for 100 Hz. Nevertheless, experimental results show that this sensing system has a wide frequency response range from a few hertz to one of kilohertz, however for some conditions, a standard optical fiber showed better result.

  18. Tapered optical fiber tip probes based on focused ion beam-milled Fabry-Perot microcavities

    NASA Astrophysics Data System (ADS)

    André, Ricardo M.; Warren-Smith, Stephen C.; Becker, Martin; Dellith, Jan; Rothhardt, Manfred; Zibaii, M. I.; Latifi, H.; Marques, Manuel B.; Bartelt, Hartmut; Frazão, Orlando

    2016-09-01

    Focused ion beam technology is combined with dynamic chemical etching to create microcavities in tapered optical fiber tips, resulting in fiber probes for temperature and refractive index sensing. Dynamic chemical etching uses hydrofluoric acid and a syringe pump to etch standard optical fibers into cone structures called tapered fiber tips where the length, shape, and cone angle can be precisely controlled. On these tips, focused ion beam is used to mill several different types of Fabry-Perot microcavities. Two main cavity types are initially compared and then combined to form a third, complex cavity structure. In the first case, a gap is milled on the tapered fiber tip which allows the external medium to penetrate the light guiding region and thus presents sensitivity to external refractive index changes. In the second, two slots that function as mirrors are milled on the tip creating a silica cavity that is only sensitive to temperature changes. Finally, both cavities are combined on a single tapered fiber tip, resulting in a multi-cavity structure capable of discriminating between temperature and refractive index variations. This dual characterization is performed with the aid of a fast Fourier transform method to separate the contributions of each cavity and thus of temperature and refractive index. Ultimately, a tapered optical fiber tip probe with sub-standard dimensions containing a multi-cavity structure is projected, fabricated, characterized and applied as a sensing element for simultaneous temperature and refractive index discrimination.

  19. An integrated CAD/CAM/robotic milling method for custom cementless femoral prostheses.

    PubMed

    Wen-ming, Xi; Ai-min, Wang; Qi, Wu; Chang-hua, Liu; Jian-fei, Zhu; Fang-fang, Xia

    2015-09-01

    Aseptic loosening is the primary cause of cementless femoral prosthesis failure and is related to the primary stability of the cementless femoral prosthesis in the femoral cavity. The primary stability affects both the osseointegration and the long-term stability of cementless femoral prostheses. A custom cementless femoral prosthesis can improve the fit and fill of the prosthesis in the femoral cavity and decrease the micromotion of the proximal prosthesis such that the primary stability of the custom prosthesis can be improved, and osseointegration of the proximal prosthesis is achieved. These results will help to achieve long-term stability in total hip arthroplasty (THA). In this paper, we introduce an integrated CAD/CAM/robotic method of milling custom cementless femoral prostheses. The 3D reconstruction model uses femoral CT images and 3D design software to design a CAD model of the custom prosthesis. After the transformation matrices between two units of the robotic system are calibrated, consistency between the CAM software and the robotic system can be achieved, and errors in the robotic milling can be limited. According to the CAD model of the custom prosthesis, the positions of the robotic tool points are produced by the CAM software of the CNC machine. The normal vector of the three adjacent robotic tool point positions determines the pose of the robotic tool point. In conclusion, the fit rate of custom pig femur stems in the femoral cavities was 90.84%. After custom femoral prostheses were inserted into the femoral cavities, the maximum gaps between the prostheses and the cavities measured less than 1 mm at the diaphysis and 1.3 mm at the metaphysis. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. Experimental stress–strain analysis of tapered silica optical fibers with nanofiber waist

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holleis, S.; Hoinkes, T.; Wuttke, C.

    2014-04-21

    We experimentally determine tensile force–elongation diagrams of tapered optical fibers with a nanofiber waist. The tapered optical fibers are produced from standard silica optical fibers using a heat and pull process. Both, the force–elongation data and scanning electron microscope images of the rupture points indicate a brittle material. Despite the small waist radii of only a few hundred nanometers, our experimental data can be fully explained by a nonlinear stress–strain model that relies on material properties of macroscopic silica optical fibers. This is an important asset when it comes to designing miniaturized optical elements as one can rely on themore » well-founded material characteristics of standard optical fibers. Based on this understanding, we demonstrate a simple and non-destructive technique that allows us to determine the waist radius of the tapered optical fiber. We find excellent agreement with independent scanning electron microscope measurements of the waist radius.« less