Sample records for target dose coverage

  1. Margin selection to compensate for loss of target dose coverage due to target motion during external‐beam radiation therapy of the lung

    PubMed Central

    Osei, Ernest; Barnett, Rob

    2015-01-01

    The aim of this study is to provide guidelines for the selection of external‐beam radiation therapy target margins to compensate for target motion in the lung during treatment planning. A convolution model was employed to predict the effect of target motion on the delivered dose distribution. The accuracy of the model was confirmed with radiochromic film measurements in both static and dynamic phantom modes. 502 unique patient breathing traces were recorded and used to simulate the effect of target motion on a dose distribution. A 1D probability density function (PDF) representing the position of the target throughout the breathing cycle was generated from each breathing trace obtained during 4D CT. Changes in the target D95 (the minimum dose received by 95% of the treatment target) due to target motion were analyzed and shown to correlate with the standard deviation of the PDF. Furthermore, the amount of target D95 recovered per millimeter of increased field width was also shown to correlate with the standard deviation of the PDF. The sensitivity of changes in dose coverage with respect to target size was also determined. Margin selection recommendations that can be used to compensate for loss of target D95 were generated based on the simulation results. These results are discussed in the context of clinical plans. We conclude that, for PDF standard deviations less than 0.4 cm with target sizes greater than 5 cm, little or no additional margins are required. Targets which are smaller than 5 cm with PDF standard deviations larger than 0.4 cm are most susceptible to loss of coverage. The largest additional required margin in this study was determined to be 8 mm. PACS numbers: 87.53.Bn, 87.53.Kn, 87.55.D‐, 87.55.Gh

  2. Single-Isocenter Multiple-Target Stereotactic Radiosurgery: Risk of Compromised Coverage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roper, Justin, E-mail: justin.roper@emory.edu; Department of Biostatistics and Bioinformatics, Winship Cancer Institute of Emory University, Atlanta, Georgia; Chanyavanich, Vorakarn

    2015-11-01

    Purpose: To determine the dosimetric effects of rotational errors on target coverage using volumetric modulated arc therapy (VMAT) for multitarget stereotactic radiosurgery (SRS). Methods and Materials: This retrospective study included 50 SRS cases, each with 2 intracranial planning target volumes (PTVs). Both PTVs were planned for simultaneous treatment to 21 Gy using a single-isocenter, noncoplanar VMAT SRS technique. Rotational errors of 0.5°, 1.0°, and 2.0° were simulated about all axes. The dose to 95% of the PTV (D95) and the volume covered by 95% of the prescribed dose (V95) were evaluated using multivariate analysis to determine how PTV coverage was relatedmore » to PTV volume, PTV separation, and rotational error. Results: At 0.5° rotational error, D95 values and V95 coverage rates were ≥95% in all cases. For rotational errors of 1.0°, 7% of targets had D95 and V95 values <95%. Coverage worsened substantially when the rotational error increased to 2.0°: D95 and V95 values were >95% for only 63% of the targets. Multivariate analysis showed that PTV volume and distance to isocenter were strong predictors of target coverage. Conclusions: The effects of rotational errors on target coverage were studied across a broad range of SRS cases. In general, the risk of compromised coverage increased with decreasing target volume, increasing rotational error and increasing distance between targets. Multivariate regression models from this study may be used to quantify the dosimetric effects of rotational errors on target coverage given patient-specific input parameters of PTV volume and distance to isocenter.« less

  3. MO-FG-CAMPUS-TeP2-04: Optimizing for a Specified Target Coverage Probability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fredriksson, A

    2016-06-15

    Purpose: The purpose of this work is to develop a method for inverse planning of radiation therapy margins. When using this method the user specifies a desired target coverage probability and the system optimizes to meet the demand without any explicit specification of margins to handle setup uncertainty. Methods: The method determines which voxels to include in an optimization function promoting target coverage in order to achieve a specified target coverage probability. Voxels are selected in a way that retains the correlation between them: The target is displaced according to the setup errors and the voxels to include are selectedmore » as the union of the displaced target regions under the x% best scenarios according to some quality measure. The quality measure could depend on the dose to the considered structure alone or could depend on the dose to multiple structures in order to take into account correlation between structures. Results: A target coverage function was applied to the CTV of a prostate case with prescription 78 Gy and compared to conventional planning using a DVH function on the PTV. Planning was performed to achieve 90% probability of CTV coverage. The plan optimized using the coverage probability function had P(D98 > 77.95 Gy) = 0.97 for the CTV. The PTV plan using a constraint on minimum DVH 78 Gy at 90% had P(D98 > 77.95) = 0.44 for the CTV. To match the coverage probability optimization, the DVH volume parameter had to be increased to 97% which resulted in 0.5 Gy higher average dose to the rectum. Conclusion: Optimizing a target coverage probability is an easily used method to find a margin that achieves the desired coverage probability. It can lead to reduced OAR doses at the same coverage probability compared to planning with margins and DVH functions.« less

  4. SU-E-T-318: The Effect of Patient Positioning Errors On Target Coverage and Cochlear Dose in Stereotactic Radiosurgery Treatment of Acoustic Neuromas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dellamonica, D.; Luo, G.; Ding, G.

    Purpose: Setup errors on the order of millimeters may cause under-dosing of targets and significant changes in dose to critical structures especially when planning with tight margins in stereotactic radiosurgery. This study evaluates the effects of these types of patient positioning uncertainties on planning target volume (PTV) coverage and cochlear dose for stereotactic treatments of acoustic neuromas. Methods: Twelve acoustic neuroma patient treatment plans were retrospectively evaluated in Brainlab iPlan RT Dose 4.1.3. All treatment beams were shaped by HDMLC from a Varian TX machine. Seven patients had planning margins of 2mm, five had 1–1.5mm. Six treatment plans were createdmore » for each patient simulating a 1mm setup error in six possible directions: anterior-posterior, lateral, and superiorinferior. The arcs and HDMLC shapes were kept the same for each plan. Change in PTV coverage and mean dose to the cochlea was evaluated for each plan. Results: The average change in PTV coverage for the 72 simulated plans was −1.7% (range: −5 to +1.1%). The largest average change in coverage was observed for shifts in the patient's superior direction (−2.9%). The change in mean cochlear dose was highly dependent upon the direction of the shift. Shifts in the anterior and superior direction resulted in an average increase in dose of 13.5 and 3.8%, respectively, while shifts in the posterior and inferior direction resulted in an average decrease in dose of 17.9 and 10.2%. The average change in dose to the cochlea was 13.9% (range: 1.4 to 48.6%). No difference was observed based on the size of the planning margin. Conclusion: This study indicates that if the positioning uncertainty is kept within 1mm the setup errors may not result in significant under-dosing of the acoustic neuroma target volumes. However, the change in mean cochlear dose is highly dependent upon the direction of the shift.« less

  5. Neighborhood-targeted and case-triggered use of a single dose of oral cholera vaccine in an urban setting: Feasibility and vaccine coverage.

    PubMed

    Parker, Lucy A; Rumunu, John; Jamet, Christine; Kenyi, Yona; Lino, Richard Laku; Wamala, Joseph F; Mpairwe, Allan M; Muller, Vincent; Llosa, Augusto E; Uzzeni, Florent; Luquero, Francisco J; Ciglenecki, Iza; Azman, Andrew S

    2017-06-01

    In June 2015, a cholera outbreak was declared in Juba, South Sudan. In addition to standard outbreak control measures, oral cholera vaccine (OCV) was proposed. As sufficient doses to cover the at-risk population were unavailable, a campaign using half the standard dosing regimen (one-dose) targeted high-risk neighborhoods and groups including neighbors of suspected cases. Here we report the operational details of this first public health use of a single-dose regimen of OCV and illustrate the feasibility of conducting highly targeted vaccination campaigns in an urban area. Neighborhoods of the city were prioritized for vaccination based on cumulative attack rates, active transmission and local knowledge of known cholera risk factors. OCV was offered to all persons older than 12 months at 20 fixed sites and to select groups, including neighbors of cholera cases after the main campaign ('case-triggered' interventions), through mobile teams. Vaccination coverage was estimated by multi-stage surveys using spatial sampling techniques. 162,377 individuals received a single-dose of OCV in the targeted neighborhoods. In these neighborhoods vaccine coverage was 68.8% (95% Confidence Interval (CI), 64.0-73.7) and was highest among children ages 5-14 years (90.0%, 95% CI 85.7-94.3), with adult men being less likely to be vaccinated than adult women (Relative Risk 0.81, 95% CI: 0.68-0.96). In the case-triggered interventions, each lasting 1-2 days, coverage varied (range: 30-87%) with an average of 51.0% (95% CI 41.7-60.3). Vaccine supply constraints and the complex realities where cholera outbreaks occur may warrant the use of flexible alternative vaccination strategies, including highly-targeted vaccination campaigns and single-dose regimens. We showed that such campaigns are feasible. Additional work is needed to understand how and when to use different strategies to best protect populations against epidemic cholera.

  6. Evaluation of dose coverage to target volume and normal tissue sparing in the adjuvant radiotherapy of gastric cancers: 3D-CRT compared with dynamic IMRT.

    PubMed

    Murthy, Kk; Shukeili, Ka; Kumar, Ss; Davis, Ca; Chandran, Rr; Namrata, S

    2010-01-01

    To assess the potential advantage of intensity-modulated radiotherapy (IMRT) over 3D-conformal radiotherapy (3D-CRT) planning in postoperative adjuvant radiotherapy for patients with gastric carcinoma. In a retrospective study, for plan comparison, dose distribution was recalculated in 15 patients treated with 3D-CRT on the contoured structures of same CT images using an IMRT technique. 3D-conformal plans with three fields and four-fields were compared with seven-field dynamic IMRT plans. The different plans were compared by analyzing the dose coverage of planning target volume using TV(95), D(mean), uniformity index, conformity index and homogeneity index parameters. To assess critical organ sparing, D(mean), D(max), dose to one-third and two-third volumes of the OARs and percentage of volumes receiving more than their tolerance doses were compared. The average dose coverage values of PTV with 3F-CRT and 4F-CRT plans were comparable, where as IMRT plans achieved better target coverage(p<0.001) with higher conformity index value of 0.81±0.07 compared to both the 3D-CRT plans. The doses to the liver and bowel reduced significantly (p<0.001) with IMRT plans compared to other 3D-CRT plans. For all OARs the percentage of volumes receiving more than their tolerance doses were reduced with the IMRT plans. This study showed that a better target coverage and significant dose reduction to OARs could be achieved with the IMRT plans. The IMRT can be preferred with caution for organ motion. The authors are currently studying organ motion in the upper abdomen to use IMRT for patient treatment.

  7. Human papillomavirus vaccination coverage in Luxembourg - Implications of lowering and restricting target age groups.

    PubMed

    Latsuzbaia, Ardashel; Arbyn, Marc; Weyers, Steven; Mossong, Joël

    2018-04-25

    In Luxembourg, a national Human Papillomavirus (HPV) vaccination programme was introduced in 2008, targeting 12-17 year old girls offering a choice of bivalent or quadrivalent vaccine free of charge. In 2015, the programme was changed offering the bivalent vaccine only to 11-13 year old girls. The aim of this study was to evaluate the HPV vaccination coverage, to assess the impact of age target changes and compare vaccination coverage to other European countries. Anonymous HPV vaccination records consisting of individual vaccine doses obtained free of charge in pharmacies between 2008 and 2016 were extracted from the Luxembourgish Social Security database. Additional aggregate tables by nationality and municipality were analysed. Of the target cohort of 39,610 girls born between 1991 and 2003 residing in Luxembourg, 24,550 (62.0%) subjects obtained at least one dose, 22,082 (55.7%) obtained at least two doses, and 17,197 (43.4%) obtained three doses of HPV vaccine. The mean age at first dose was 13.7 years during 2008-14 and 12.7 years in 2016 after the age target change. Coverage varied significantly by nationality (p < 0.0001): Portuguese (80%), former Yugoslavs (74%), Luxembourgish (54%), Belgian (52%), German (47%), French (39%) and other nationalities (51%). Coverage varied also by geographical region, with lower rates (<50%) noted in some Northern and Central areas of Luxembourg (range: 38% to 78%). Overall HPV vaccination coverage in Luxembourg is moderate and varied by nationality and region. The policy changes in 2015 did not have a substantial impact except lowering age at initiating vaccination. Options to improve coverage deserve further investigation. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  8. Sensitivity of postplanning target and OAR coverage estimates to dosimetric margin distribution sampling parameters.

    PubMed

    Xu, Huijun; Gordon, J James; Siebers, Jeffrey V

    2011-02-01

    A dosimetric margin (DM) is the margin in a specified direction between a structure and a specified isodose surface, corresponding to a prescription or tolerance dose. The dosimetric margin distribution (DMD) is the distribution of DMs over all directions. Given a geometric uncertainty model, representing inter- or intrafraction setup uncertainties or internal organ motion, the DMD can be used to calculate coverage Q, which is the probability that a realized target or organ-at-risk (OAR) dose metric D, exceeds the corresponding prescription or tolerance dose. Postplanning coverage evaluation quantifies the percentage of uncertainties for which target and OAR structures meet their intended dose constraints. The goal of the present work is to evaluate coverage probabilities for 28 prostate treatment plans to determine DMD sampling parameters that ensure adequate accuracy for postplanning coverage estimates. Normally distributed interfraction setup uncertainties were applied to 28 plans for localized prostate cancer, with prescribed dose of 79.2 Gy and 10 mm clinical target volume to planning target volume (CTV-to-PTV) margins. Using angular or isotropic sampling techniques, dosimetric margins were determined for the CTV, bladder and rectum, assuming shift invariance of the dose distribution. For angular sampling, DMDs were sampled at fixed angular intervals w (e.g., w = 1 degree, 2 degrees, 5 degrees, 10 degrees, 20 degrees). Isotropic samples were uniformly distributed on the unit sphere resulting in variable angular increments, but were calculated for the same number of sampling directions as angular DMDs, and accordingly characterized by the effective angular increment omega eff. In each direction, the DM was calculated by moving the structure in radial steps of size delta (=0.1, 0.2, 0.5, 1 mm) until the specified isodose was crossed. Coverage estimation accuracy deltaQ was quantified as a function of the sampling parameters omega or omega eff and delta. The

  9. TU-AB-BRB-00: New Methods to Ensure Target Coverage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2015-06-15

    The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. Themore » treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To

  10. Human papillomavirus vaccination coverage using two-dose or three-dose schedule criteria.

    PubMed

    Lin, Xia; Rodgers, Loren; Zhu, Liping; Stokley, Shannon; Meites, Elissa; Markowitz, Lauri E

    2017-10-13

    In October 2016, the Advisory Committee on Immunization Practices (ACIP) updated the human papillomavirus (HPV) vaccination recommendation to include a 2-dose schedule for U.S. adolescents initiating the vaccine series before their 15th birthday. We analyzed records for >4million persons aged 9-17years receiving any HPV vaccine by the end of each quarter during January 1, 2014-September 30, 2016 from six Immunization Information Systems Sentinel Sites, and reclassified HPV vaccination up-to-date coverage according to the updated recommendations. Compared with HPV vaccination up-to-date coverage by the 3-dose schedule only, including criteria for either a 2-dose or 3-dose schedule increased up-to-date coverage in 11-12, 13-14, and 15-17 year-olds by 4.5-8.5 percentage points. The difference between 3-dose up-to-date coverage and 2- or 3-dose up-to-date coverage was greatest in late 2016. These data provide baseline HPV vaccination coverage using current ACIP recommendations. Published by Elsevier Ltd.

  11. Sensitivity of postplanning target and OAR coverage estimates to dosimetric margin distribution sampling parameters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu Huijun; Gordon, J. James; Siebers, Jeffrey V.

    2011-02-15

    Purpose: A dosimetric margin (DM) is the margin in a specified direction between a structure and a specified isodose surface, corresponding to a prescription or tolerance dose. The dosimetric margin distribution (DMD) is the distribution of DMs over all directions. Given a geometric uncertainty model, representing inter- or intrafraction setup uncertainties or internal organ motion, the DMD can be used to calculate coverage Q, which is the probability that a realized target or organ-at-risk (OAR) dose metric D{sub v} exceeds the corresponding prescription or tolerance dose. Postplanning coverage evaluation quantifies the percentage of uncertainties for which target and OAR structuresmore » meet their intended dose constraints. The goal of the present work is to evaluate coverage probabilities for 28 prostate treatment plans to determine DMD sampling parameters that ensure adequate accuracy for postplanning coverage estimates. Methods: Normally distributed interfraction setup uncertainties were applied to 28 plans for localized prostate cancer, with prescribed dose of 79.2 Gy and 10 mm clinical target volume to planning target volume (CTV-to-PTV) margins. Using angular or isotropic sampling techniques, dosimetric margins were determined for the CTV, bladder and rectum, assuming shift invariance of the dose distribution. For angular sampling, DMDs were sampled at fixed angular intervals {omega} (e.g., {omega}=1 deg., 2 deg., 5 deg., 10 deg., 20 deg.). Isotropic samples were uniformly distributed on the unit sphere resulting in variable angular increments, but were calculated for the same number of sampling directions as angular DMDs, and accordingly characterized by the effective angular increment {omega}{sub eff}. In each direction, the DM was calculated by moving the structure in radial steps of size {delta}(=0.1,0.2,0.5,1 mm) until the specified isodose was crossed. Coverage estimation accuracy {Delta}Q was quantified as a function of the sampling parameters

  12. Poster - 36: Effect of Planning Target Volume Coverage on the Dose Delivered in Lung Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dekker, Chris; Wierzbicki, Marcin

    2016-08-15

    Purpose: In lung radiotherapy, breathing motion may be encompassed by contouring the internal target volume (ITV). Remaining uncertainties are included in a geometrical expansion to the planning target volume (PTV). In IMRT, the treatment is then optimized until a desired PTV fraction is covered by the appropriate dose. The resulting beams often carry high fluence in the PTV margin to overcome low lung density and to generate steep dose gradients. During treatment, the high density tumour can enter the PTV margin, potentially increasing target dose. Thus, planning lung IMRT with a reduced PTV dose may still achieve the desired ITVmore » dose during treatment. Methods: A retrospective analysis was carried out with 25 IMRT plans prescribed to 63 Gy in 30 fractions. The plans were re-normalized to cover various fractions of the PTV by different isodose lines. For each case, the isocentre was moved using 125 shifts derived from all 3D combinations of 0 mm, (PTV margin - 1 mm), and PTV margin. After each shift, the dose was recomputed to approximate the delivered dose. Results and Conclusion: Our plans typically cover 95% of the PTV by 95% of the dose. Reducing the PTV covered to 94% did not significantly reduce the delivered ITV doses for (PTV margin - 1 mm) shifts. Target doses were reduced significantly for all other shifts and planning goals studied. Thus, a reduced planning goal will likely deliver the desired target dose as long as the ITV rarely enters the last mm of the PTV margin.« less

  13. Edema worsens target coverage in high-dose-rate interstitial brachytherapy of mobile tongue cancer: a report of two cases.

    PubMed

    Yoshida, Ken; Yamazaki, Hideya; Kotsuma, Tadayuki; Akiyama, Hironori; Takenaka, Tadashi; Masui, Koji; Yoshioka, Yasuo; Uesugi, Yasuo; Shimbo, Taiju; Yoshikawa, Nobuhiko; Yoshioka, Hiroto; Arika, Takumi; Tanaka, Eiichi; Narumi, Yoshifumi

    2017-02-01

    We report our study on two patients to highlight the risk of underdosage of the clinical target volume (CTV) due to edema during high-dose-rate interstitial brachytherapy (HDR-ISBT) of mobile tongue cancer. To treat the lateral side of the CTV, flexible applicator tubes were implanted on the mouth floor. Two-dimensional planning was performed using X-ray images for Case 1, and three-dimensional (3D) planning was performed using computed tomography (CT) for Case 2. Prescribed doses for both cases were 54 Gy in nine fractions. Case 1 was treated for cancer of the right lateral border of the tongue in 2005. Tongue edema occurred after implantation, and part of the lateral border of the tongue protruded between the applicator tubes. Acute mucosal reaction abated in the protruded area earlier than in the other parts of the CTV. In this case, the tumor recurred in this area 5 months after the treatment. Case 2 was treated for cancer of the left lateral border of the tongue. Because tongue edema occurred in this case also, plastic splints were inserted between the applicator tubes to push the edematous region into the irradiated area. The mucosal surface of the CTV was covered by the 70% isodose, and 100% isodose line for before and after splint insertion. Local control of the tumor was achieved 4 years after treatment. To ensure sufficient target coverage, 3D image-based planning using CT should be performed, followed by re-planning using repeated CT as needed. Also, the development of devices to prevent protrusion of the edematous tissue outside the target area will help to ensure the full dosing of CTV.

  14. Helical tomotherapy for radiotherapy in esophageal cancer: a preferred plan with better conformal target coverage and more homogeneous dose distribution.

    PubMed

    Chen, Yi-Jen; Liu, An; Han, Chunhui; Tsai, Peter T; Schultheiss, Timothy E; Pezner, Richard D; Vora, Nilesh; Lim, Dean; Shibata, Stephen; Kernstine, Kemp H; Wong, Jeffrey Y C

    2007-01-01

    We compare different radiotherapy techniques-helical tomotherapy (tomotherapy), step-and-shoot IMRT (IMRT), and 3-dimensional conformal radiotherapy (3DCRT)-for patients with mid-distal esophageal carcinoma on the basis of dosimetric analysis. Six patients with locally advanced mid-distal esophageal carcinoma were treated with neoadjuvant chemoradiation followed by surgery. Radiotherapy included 50 Gy to gross planning target volume (PTV) and 45 Gy to elective PTV in 25 fractions. Tomotherapy, IMRT, and 3DCRT plans were generated. Dose-volume histograms (DVHs), homogeneity index (HI), volumes of lung receiving more than 10, 15, or 20 Gy (V(10), V(15), V(20)), and volumes of heart receiving more than 30 or 45 Gy (V(30), V(45)) were determined. Statistical analysis was performed by paired t-tests. By isodose distributions and DVHs, tomotherapy plans showed sharper dose gradients, more conformal coverage, and better HI for both gross and elective PTVs compared with IMRT or 3DCRT plans. Mean V(20) of lung was significantly reduced in tomotherapy plans. However, tomotherapy and IMRT plans resulted in larger V(10) of lung compared to 3DCRT plans. The heart was significantly spared in tomotherapy and IMRT plans compared to 3DCRT plans in terms of V(30) and V(45). We conclude that tomotherapy plans are superior in terms of target conformity, dose homogeneity, and V(20) of lung.

  15. Utilization of cone-beam CT for offline evaluation of target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment.

    PubMed

    Paluska, Petr; Hanus, Josef; Sefrova, Jana; Rouskova, Lucie; Grepl, Jakub; Jansa, Jan; Kasaova, Linda; Hodek, Miroslav; Zouhar, Milan; Vosmik, Milan; Petera, Jiri

    2012-01-01

    To assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction. Implementation of IGRT should influence safety margins. Utilization of cone-beam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose distribution. Seventeen prostate patients were treated with daily bony anatomy image-guidance. Cone-beam CT (CBCT) scans were acquired once a week immediately after bony anatomy alignment. After the prostate, seminal vesicles, rectum and bladder were contoured, the delivered dose distribution was reconstructed. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed a 1 cm safety margin. Alternative plans assuming a smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with the initial ones. Rectal and bladder volumes irradiated with doses higher than 75 Gy, 70 Gy, 60 Gy, 50 Gy and 40 Gy were analyzed. In 12% of reconstructed plans the prostate coverage was not sufficient. The prostate underdosage was observed in 5 patients. Coverage of seminal vesicles was not satisfactory in 3% of plans. Most of the target underdosage corresponded to excessive rectal or bladder filling. Evaluation of alternative plans assuming a smaller 7 mm margin revealed 22% and 11% of plans where prostate and seminal vesicles coverage, respectively, was compromised. These were distributed over 8 and 7 patients, respectively. Sufficient dose coverage of target volumes was not achieved for all patients. Reducing of safety margin is not acceptable. Initial rectal and bladder volumes cannot be considered representative for subsequent treatment.

  16. On Connected Target k-Coverage in Heterogeneous Wireless Sensor Networks.

    PubMed

    Yu, Jiguo; Chen, Ying; Ma, Liran; Huang, Baogui; Cheng, Xiuzhen

    2016-01-15

    Coverage and connectivity are two important performance evaluation indices for wireless sensor networks (WSNs). In this paper, we focus on the connected target k-coverage (CTC k) problem in heterogeneous wireless sensor networks (HWSNs). A centralized connected target k-coverage algorithm (CCTC k) and a distributed connected target k-coverage algorithm (DCTC k) are proposed so as to generate connected cover sets for energy-efficient connectivity and coverage maintenance. To be specific, our proposed algorithms aim at achieving minimum connected target k-coverage, where each target in the monitored region is covered by at least k active sensor nodes. In addition, these two algorithms strive to minimize the total number of active sensor nodes and guarantee that each sensor node is connected to a sink, such that the sensed data can be forwarded to the sink. Our theoretical analysis and simulation results show that our proposed algorithms outperform a state-of-art connected k-coverage protocol for HWSNs.

  17. Single line source with and without vaginal loading and the impact on target coverage and organ at risk doses for cervix cancer Stages IB, II, and IIIB: treatment planning simulation in patients treated with MRI-guided adaptive brachytherapy in a multicentre study (EMBRACE).

    PubMed

    Nkiwane, Karen S; Pötter, Richard; Tanderup, Kari; Federico, Mario; Lindegaard, Jacob C; Kirisits, Christian

    2013-01-01

    Three-dimensional evaluation and comparison of target and organs at risk (OARs) doses from two traditional standard source loading patterns in the frame of MRI-guided cervical cancer brachytherapy for various clinical scenarios based on patient data collected in a multicenter trial setting. Two nonoptimized three-dimensional MRI-based treatment plans, Plan 1 (tandem and vaginal loading) and Plan 2 (tandem loading only), were generated for 134 patients from seven centers participating in the EMBRACE study. Both plans were normalized to point A (Pt. A). Target and OAR doses were evaluated in terms of minimum dose to 90% of the high-risk clinical target volume (HRCTV D90) grouped by tumor stage and minimum dose to the most exposed 2cm³ of the OARs volume. An HRCTV D90 ≥ Pt. A was achieved in 82% and 44% of the patients with Plans 1 and 2, respectively. Median HRCTV D90 with Plans 1 and 2 was 120% and 90% of Pt. A dose, respectively. Both plans had optimal dose coverage in 88% of Stage IB tumors; however, the tandem-only plan resulted in about 50% of dose reduction to the vagina and rectum. For Stages IIB and IIIB, Plan 1 had on average 35% better target coverage but with significant doses to OARs. Standard tandem loading alone results in good target coverage in most Stage IB tumors without violating OAR dose constraints. For Stage IIB tumors, standard vaginal loading improves the therapeutic window, however needs optimization to fulfill the dose prescription for target and OAR. In Stage IIIB, even optimized vaginal loading often does not fulfill the needs for dose prescription. The significant dose variation across various clinical scenarios for both target and OARs indicates the need for image-guided brachytherapy for optimal dose adaptation both for limited and advanced diseases. Copyright © 2013 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  18. Dose-shaping using targeted sparse optimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sayre, George A.; Ruan, Dan

    2013-07-15

    Purpose: Dose volume histograms (DVHs) are common tools in radiation therapy treatment planning to characterize plan quality. As statistical metrics, DVHs provide a compact summary of the underlying plan at the cost of losing spatial information: the same or similar dose-volume histograms can arise from substantially different spatial dose maps. This is exactly the reason why physicians and physicists scrutinize dose maps even after they satisfy all DVH endpoints numerically. However, up to this point, little has been done to control spatial phenomena, such as the spatial distribution of hot spots, which has significant clinical implications. To this end, themore » authors propose a novel objective function that enables a more direct tradeoff between target coverage, organ-sparing, and planning target volume (PTV) homogeneity, and presents our findings from four prostate cases, a pancreas case, and a head-and-neck case to illustrate the advantages and general applicability of our method.Methods: In designing the energy minimization objective (E{sub tot}{sup sparse}), the authors utilized the following robust cost functions: (1) an asymmetric linear well function to allow differential penalties for underdose, relaxation of prescription dose, and overdose in the PTV; (2) a two-piece linear function to heavily penalize high dose and mildly penalize low and intermediate dose in organs-at risk (OARs); and (3) a total variation energy, i.e., the L{sub 1} norm applied to the first-order approximation of the dose gradient in the PTV. By minimizing a weighted sum of these robust costs, general conformity to dose prescription and dose-gradient prescription is achieved while encouraging prescription violations to follow a Laplace distribution. In contrast, conventional quadratic objectives are associated with a Gaussian distribution of violations, which is less forgiving to large violations of prescription than the Laplace distribution. As a result, the proposed objective E

  19. Real-time intraoperative evaluation of implant quality and dose correction during prostate brachytherapy consistently improves target coverage using a novel image fusion and optimization program.

    PubMed

    Zelefsky, Michael J; Cohen, Gilad N; Taggar, Amandeep S; Kollmeier, Marisa; McBride, Sean; Mageras, Gig; Zaider, Marco

    Our purpose was to describe the process and outcome of performing postimplantation dosimetric assessment and intraoperative dose correction during prostate brachytherapy using a novel image fusion-based treatment-planning program. Twenty-six consecutive patients underwent intraoperative real-time corrections of their dose distributions at the end of their permanent seed interstitial procedures. After intraoperatively planned seeds were implanted and while the patient remained in the lithotomy position, a cone beam computed tomography scan was obtained to assess adequacy of the prescription dose coverage. The implanted seed positions were automatically segmented from the cone-beam images, fused onto a new set of acquired ultrasound images, reimported into the planning system, and recontoured. Dose distributions were recalculated based upon actual implanted seed coordinates and recontoured ultrasound images and were reviewed. If any dose deficiencies within the prostate target were identified, additional needles and seeds were added. Once an implant was deemed acceptable, the procedure was completed, and anesthesia was reversed. When the intraoperative ultrasound-based quality assurance assessment was performed after seed placement, the median volume receiving 100% of the dose (V100) was 93% (range, 74% to 98%). Before seed correction, 23% (6/26) of cases were noted to have V100 <90%. Based on this intraoperative assessment and replanning, additional seeds were placed into dose-deficient regions within the target to improve target dose distributions. Postcorrection, the median V100 was 97% (range, 93% to 99%). Following intraoperative dose corrections, all implants achieved V100 >90%. In these patients, postimplantation evaluation during the actual prostate seed implant procedure was successfully applied to determine the need for additional seeds to correct dose deficiencies before anesthesia reversal. When applied, this approach should significantly reduce

  20. Continuous monitoring and intrafraction target position correction during treatment improves target coverage for patients undergoing SBRT prostate therapy.

    PubMed

    Lovelock, D Michael; Messineo, Alessandra P; Cox, Brett W; Kollmeier, Marisa A; Zelefsky, Michael J

    2015-03-01

    To compare the potential benefits of continuous monitoring of prostate position and intervention (CMI) using 2-mm displacement thresholds during stereotactic body radiation therapy (SBRT) treatment to those of a conventional image-guided procedure involving single localization prior to treatment. Eighty-nine patients accrued to a prostate SBRT dose escalation protocol were implanted with radiofrequency transponder beacons. The planning target volume (PTV) margin was 5 mm in all directions, except for 3 mm in the posterior direction. The prostate was kept within 2 mm of its planned position by the therapists halting dose delivery and, if necessary, correcting the couch position. We computed the number, type, and time required for interventions and where the prostate would have been during dose delivery had there been, instead, a single image-guided setup procedure prior to each treatment. Distributions of prostate displacements were computed as a function of time. After the initial setup, 1.7 interventions per fraction were required, with a concomitant increase in time for dose delivery of approximately 65 seconds. Small systematic drifts in prostate position in the posterior and inferior directions were observed in the study patients. Without CMI, intrafractional motion would have resulted in approximately 10% of patients having a delivered dose that did not meet our clinical coverage requirement, that is, a PTV D95 of >90%. The posterior PTV margin required for 95% of the dose to be delivered with the target positioned within the PTV was computed as a function of time. The margin necessary was found to increase by 2 mm every 5 minutes, starting from the time of the imaging procedure. CMI using a tight 2-mm displacement threshold was not only feasible but was found to deliver superior PTV coverage compared with the conventional image-guided procedure in the SBRT setting. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Continuous Monitoring and Intrafraction Target Position Correction During Treatment Improves Target Coverage for Patients Undergoing SBRT Prostate Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lovelock, D. Michael, E-mail: lovelocm@mskcc.org; Messineo, Alessandra P.; Cox, Brett W.

    2015-03-01

    Purpose: To compare the potential benefits of continuous monitoring of prostate position and intervention (CMI) using 2-mm displacement thresholds during stereotactic body radiation therapy (SBRT) treatment to those of a conventional image-guided procedure involving single localization prior to treatment. Methods and Materials: Eighty-nine patients accrued to a prostate SBRT dose escalation protocol were implanted with radiofrequency transponder beacons. The planning target volume (PTV) margin was 5 mm in all directions, except for 3 mm in the posterior direction. The prostate was kept within 2 mm of its planned position by the therapists halting dose delivery and, if necessary, correcting themore » couch position. We computed the number, type, and time required for interventions and where the prostate would have been during dose delivery had there been, instead, a single image-guided setup procedure prior to each treatment. Distributions of prostate displacements were computed as a function of time. Results: After the initial setup, 1.7 interventions per fraction were required, with a concomitant increase in time for dose delivery of approximately 65 seconds. Small systematic drifts in prostate position in the posterior and inferior directions were observed in the study patients. Without CMI, intrafractional motion would have resulted in approximately 10% of patients having a delivered dose that did not meet our clinical coverage requirement, that is, a PTV D95 of >90%. The posterior PTV margin required for 95% of the dose to be delivered with the target positioned within the PTV was computed as a function of time. The margin necessary was found to increase by 2 mm every 5 minutes, starting from the time of the imaging procedure. Conclusions: CMI using a tight 2-mm displacement threshold was not only feasible but was found to deliver superior PTV coverage compared with the conventional image-guided procedure in the SBRT setting.« less

  2. An evaluation of voluntary 2-dose varicella vaccination coverage in New York City public schools.

    PubMed

    Doll, Margaret K; Rosen, Jennifer B; Bialek, Stephanie R; Szeto, Hiram; Zimmerman, Christopher M

    2015-05-01

    We assessed coverage for 2-dose varicella vaccination, which is not required for school entry, among New York City public school students and examined characteristics associated with receipt of 2 doses. We measured receipt of either at least 1 or 2 doses of varicella vaccine among students aged 4 years and older in a sample of 336 public schools (n = 223 864 students) during the 2010 to 2011 school year. Data came from merged student vaccination records from 2 administrative data systems. We conducted multivariable regression to assess associations of age, gender, race/ethnicity, and school location with 2-dose prevalence. Coverage with at least 1 varicella dose was 96.2% (95% confidence interval [CI] = 96.2%, 96.3%); coverage with at least 2 doses was 64.8% (95% CI = 64.6%, 64.9%). Increasing student age, non-Hispanic White race/ethnicity, and attendance at school in Staten Island were associated with lower 2-dose coverage. A 2-dose varicella vaccine requirement for school entry would likely improve 2-dose coverage, eliminate coverage disparities, and prevent disease.

  3. Effect of lung and target density on small-field dose coverage and PTV definition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Higgins, Patrick D., E-mail: higgi010@umn.edu; Ehler, Eric D.; Cho, Lawrence C.

    We have studied the effect of target and lung density on block margin for small stereotactic body radiotherapy (SBRT) targets. A phantom (50 × 50 × 50 cm{sup 3}) was created in the Pinnacle (V9.2) planning system with a 23-cm diameter lung region of interest insert. Diameter targets of 1.6, 2.0, 3.0, and 4.0 cm were placed in the lung region of interest and centered at a physical depth of 15 cm. Target densities evaluated were 0.1 to 1.0 g/cm{sup 3}, whereas the surrounding lung density was varied between 0.05 and 0.6 g/cm{sup 3}. A dose of 100 cGy wasmore » delivered to the isocenter via a single 6-MV field, and the ratio of the average dose to points defining the lateral edges of the target to the isocenter dose was recorded for each combination. Field margins were varied from none to 1.5 cm in 0.25-cm steps. Data obtained in the phantom study were used to predict planning treatment volume (PTV) margins that would match the clinical PTV and isodose prescription for a clinical set of 39 SBRT cases. The average internal target volume (ITV) density was 0.73 ± 0.17, average local lung density was 0.33 ± 0.16, and average ITV diameter was 2.16 ± 0.8 cm. The phantom results initially underpredicted PTV margins by 0.35 cm. With this offset included in the model, the ratio of predicted-to-clinical PTVs was 1.05 ± 0.32. For a given target and lung density, it was found that treatment margin was insensitive to target diameter, except for the smallest (1.6-cm diameter) target, for which the treatment margin was more sensitive to density changes than the larger targets. We have developed a graphical relationship for block margin as a function of target and lung density, which should save time in the planning phase by shortening the design of PTV margins that can satisfy Radiation Therapy Oncology Group mandated treatment volume ratios.« less

  4. An Evaluation of Voluntary 2-Dose Varicella Vaccination Coverage in New York City Public Schools

    PubMed Central

    Rosen, Jennifer B.; Bialek, Stephanie R.; Szeto, Hiram; Zimmerman, Christopher M.

    2015-01-01

    Objectives. We assessed coverage for 2-dose varicella vaccination, which is not required for school entry, among New York City public school students and examined characteristics associated with receipt of 2 doses. Methods. We measured receipt of either at least 1 or 2 doses of varicella vaccine among students aged 4 years and older in a sample of 336 public schools (n = 223 864 students) during the 2010 to 2011 school year. Data came from merged student vaccination records from 2 administrative data systems. We conducted multivariable regression to assess associations of age, gender, race/ethnicity, and school location with 2-dose prevalence. Results. Coverage with at least 1 varicella dose was 96.2% (95% confidence interval [CI] = 96.2%, 96.3%); coverage with at least 2 doses was 64.8% (95% CI = 64.6%, 64.9%). Increasing student age, non-Hispanic White race/ethnicity, and attendance at school in Staten Island were associated with lower 2-dose coverage. Conclusions. A 2-dose varicella vaccine requirement for school entry would likely improve 2-dose coverage, eliminate coverage disparities, and prevent disease. PMID:25521904

  5. Coverage-based constraints for IMRT optimization

    NASA Astrophysics Data System (ADS)

    Mescher, H.; Ulrich, S.; Bangert, M.

    2017-09-01

    Radiation therapy treatment planning requires an incorporation of uncertainties in order to guarantee an adequate irradiation of the tumor volumes. In current clinical practice, uncertainties are accounted for implicitly with an expansion of the target volume according to generic margin recipes. Alternatively, it is possible to account for uncertainties by explicit minimization of objectives that describe worst-case treatment scenarios, the expectation value of the treatment or the coverage probability of the target volumes during treatment planning. In this note we show that approaches relying on objectives to induce a specific coverage of the clinical target volumes are inevitably sensitive to variation of the relative weighting of the objectives. To address this issue, we introduce coverage-based constraints for intensity-modulated radiation therapy (IMRT) treatment planning. Our implementation follows the concept of coverage-optimized planning that considers explicit error scenarios to calculate and optimize patient-specific probabilities q(\\hat{d}, \\hat{v}) of covering a specific target volume fraction \\hat{v} with a certain dose \\hat{d} . Using a constraint-based reformulation of coverage-based objectives we eliminate the trade-off between coverage and competing objectives during treatment planning. In-depth convergence tests including 324 treatment plan optimizations demonstrate the reliability of coverage-based constraints for varying levels of probability, dose and volume. General clinical applicability of coverage-based constraints is demonstrated for two cases. A sensitivity analysis regarding penalty variations within this planing study based on IMRT treatment planning using (1) coverage-based constraints, (2) coverage-based objectives, (3) probabilistic optimization, (4) robust optimization and (5) conventional margins illustrates the potential benefit of coverage-based constraints that do not require tedious adjustment of target volume objectives.

  6. Target Coverage in Wireless Sensor Networks with Probabilistic Sensors

    PubMed Central

    Shan, Anxing; Xu, Xianghua; Cheng, Zongmao

    2016-01-01

    Sensing coverage is a fundamental problem in wireless sensor networks (WSNs), which has attracted considerable attention. Conventional research on this topic focuses on the 0/1 coverage model, which is only a coarse approximation to the practical sensing model. In this paper, we study the target coverage problem, where the objective is to find the least number of sensor nodes in randomly-deployed WSNs based on the probabilistic sensing model. We analyze the joint detection probability of target with multiple sensors. Based on the theoretical analysis of the detection probability, we formulate the minimum ϵ-detection coverage problem. We prove that the minimum ϵ-detection coverage problem is NP-hard and present an approximation algorithm called the Probabilistic Sensor Coverage Algorithm (PSCA) with provable approximation ratios. To evaluate our design, we analyze the performance of PSCA theoretically and also perform extensive simulations to demonstrate the effectiveness of our proposed algorithm. PMID:27618902

  7. A Max-Flow Based Algorithm for Connected Target Coverage with Probabilistic Sensors

    PubMed Central

    Shan, Anxing; Xu, Xianghua; Cheng, Zongmao; Wang, Wensheng

    2017-01-01

    Coverage is a fundamental issue in the research field of wireless sensor networks (WSNs). Connected target coverage discusses the sensor placement to guarantee the needs of both coverage and connectivity. Existing works largely leverage on the Boolean disk model, which is only a coarse approximation to the practical sensing model. In this paper, we focus on the connected target coverage issue based on the probabilistic sensing model, which can characterize the quality of coverage more accurately. In the probabilistic sensing model, sensors are only be able to detect a target with certain probability. We study the collaborative detection probability of target under multiple sensors. Armed with the analysis of collaborative detection probability, we further formulate the minimum ϵ-connected target coverage problem, aiming to minimize the number of sensors satisfying the requirements of both coverage and connectivity. We map it into a flow graph and present an approximation algorithm called the minimum vertices maximum flow algorithm (MVMFA) with provable time complex and approximation ratios. To evaluate our design, we analyze the performance of MVMFA theoretically and also conduct extensive simulation studies to demonstrate the effectiveness of our proposed algorithm. PMID:28587084

  8. A Max-Flow Based Algorithm for Connected Target Coverage with Probabilistic Sensors.

    PubMed

    Shan, Anxing; Xu, Xianghua; Cheng, Zongmao; Wang, Wensheng

    2017-05-25

    Coverage is a fundamental issue in the research field of wireless sensor networks (WSNs). Connected target coverage discusses the sensor placement to guarantee the needs of both coverage and connectivity. Existing works largely leverage on the Boolean disk model, which is only a coarse approximation to the practical sensing model. In this paper, we focus on the connected target coverage issue based on the probabilistic sensing model, which can characterize the quality of coverage more accurately. In the probabilistic sensing model, sensors are only be able to detect a target with certain probability. We study the collaborative detection probability of target under multiple sensors. Armed with the analysis of collaborative detection probability, we further formulate the minimum ϵ -connected target coverage problem, aiming to minimize the number of sensors satisfying the requirements of both coverage and connectivity. We map it into a flow graph and present an approximation algorithm called the minimum vertices maximum flow algorithm (MVMFA) with provable time complex and approximation ratios. To evaluate our design, we analyze the performance of MVMFA theoretically and also conduct extensive simulation studies to demonstrate the effectiveness of our proposed algorithm.

  9. Evaluation of target coverage and margins adequacy during CyberKnife Lung Optimized Treatment.

    PubMed

    Ricotti, Rosalinda; Seregni, Matteo; Ciardo, Delia; Vigorito, Sabrina; Rondi, Elena; Piperno, Gaia; Ferrari, Annamaria; Zerella, Maria Alessia; Arculeo, Simona; Francia, Claudia Maria; Sibio, Daniela; Cattani, Federica; De Marinis, Filippo; Spaggiari, Lorenzo; Orecchia, Roberto; Riboldi, Marco; Baroni, Guido; Jereczek-Fossa, Barbara Alicja

    2018-04-01

    Evaluation of target coverage and verification of safety margins, in motion management strategies implemented by Lung Optimized Treatment (LOT) module in CyberKnife system. Three fiducial-less motion management strategies provided by LOT can be selected according to tumor visibility in the X ray images acquired during treatment. In 2-view modality the tumor is visible in both X ray images and full motion tracking is performed. In 1-view modality the tumor is visible in a single X ray image, therefore, motion tracking is combined with an internal target volume (ITV)-based margin expansion. In 0-view modality the lesion is not visible, consequently the treatment relies entirely on an ITV-based approach. Data from 30 patients treated in 2-view modality were selected providing information on the three-dimensional tumor motion in correspondence to each X ray image. Treatments in 1-view and 0-view modalities were simulated by processing log files and planning volumes. Planning target volume (PTV) margins were defined according to the tracking modality: end-exhale clinical target volume (CTV) + 3 mm in 2-view and ITV + 5 mm in 0-view. In the 1-view scenario, the ITV encompasses only tumor motion along the non-visible direction. Then, non-uniform ITV to PTV margins were applied: 3 mm and 5 mm in the visible and non-visible direction, respectively. We defined the coverage of each voxel of the CTV as the percentage of X ray images where such voxel was included in the PTV. In 2-view modality coverage was calculated as the intersection between the CTV centred on the imaged target position and the PTV centred on the predicted target position, as recorded in log files. In 1-view modality, coverage was calculated as the intersection between the CTV centred on the imaged target position and the PTV centred on the projected predictor data. In 0-view modality coverage was calculated as the intersection between the CTV centred on the imaged target position and the non

  10. Voluntary Deep Inspiration Breath-hold Reduces the Heart Dose Without Compromising the Target Volume Coverage During Radiotherapy for Left-sided Breast Cancer.

    PubMed

    Al-Hammadi, Noora; Caparrotti, Palmira; Naim, Carole; Hayes, Jillian; Rebecca Benson, Katherine; Vasic, Ana; Al-Abdulla, Hissa; Hammoud, Rabih; Divakar, Saju; Petric, Primoz

    2018-03-01

    were ≤ 2.1 mm. These results did not differ significantly from historic FB controls. When compared with FB, V-DIBH demonstrated high setup accuracy and enabled significant reduction of cardiac doses without compromising the target volume coverage. Differences in lung doses were non-significant.

  11. Optimization of Self-Directed Target Coverage in Wireless Multimedia Sensor Network

    PubMed Central

    Yang, Yang; Wang, Yufei; Pi, Dechang; Wang, Ruchuan

    2014-01-01

    Video and image sensors in wireless multimedia sensor networks (WMSNs) have directed view and limited sensing angle. So the methods to solve target coverage problem for traditional sensor networks, which use circle sensing model, are not suitable for WMSNs. Based on the FoV (field of view) sensing model and FoV disk model proposed, how expected multimedia sensor covers the target is defined by the deflection angle between target and the sensor's current orientation and the distance between target and the sensor. Then target coverage optimization algorithms based on expected coverage value are presented for single-sensor single-target, multisensor single-target, and single-sensor multitargets problems distinguishingly. Selecting the orientation that sensor rotated to cover every target falling in the FoV disk of that sensor for candidate orientations and using genetic algorithm to multisensor multitargets problem, which has NP-complete complexity, then result in the approximated minimum subset of sensors which covers all the targets in networks. Simulation results show the algorithm's performance and the effect of number of targets on the resulting subset. PMID:25136667

  12. Intensity-Modulated Radiotherapy for Craniospinal Irradiation: Target Volume Considerations, Dose Constraints, and Competing Risks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, William; Filion, Edith; Roberge, David

    2007-09-01

    Purpose: To report the results of an analysis of dose received to tissues and organs outside the target volume, in the setting of spinal axis irradiation for the treatment of medulloblastoma, using three treatment techniques. Methods and Materials: Treatment plans (total dose, 23.4 Gy) for a standard two-dimensional (2D) technique, a three-dimensional (3D) technique using a 3D imaging-based target volume, and an intensity-modulated radiotherapy (IMRT) technique, were compared for 3 patients in terms of dose-volume statistics for target coverage, as well as organ at risk (OAR) and overall tissue sparing. Results: Planning target volume coverage and dose homogeneity was superiormore » for the IMRT plans for V{sub 95%} (IMRT, 100%; 3D, 96%; 2D, 98%) and V{sub 107%} (IMRT, 3%; 3D, 38%; 2D, 37%). In terms of OAR sparing, the IMRT plan was better for all organs and whole-body contour when comparing V{sub 10Gy}, V{sub 15Gy}, and V{sub 20Gy}. The 3D plan was superior for V{sub 5Gy} and below. For the heart and liver in particular, the IMRT plans provided considerable sparing in terms of V{sub 10Gy} and above. In terms of the integral dose, the IMRT plans were superior for liver (IMRT, 21.9 J; 3D, 28.6 J; 2D, 38.6 J) and heart (IMRT, 9 J; 3D, 14.1J; 2D, 19.4 J), the 3D plan for the body contour (IMRT, 349 J; 3D, 337 J; 2D, 555 J). Conclusions: Intensity-modulated radiotherapy is a valid treatment option for spinal axis irradiation. We have shown that IMRT results in sparing of organs at risk without a significant increase in integral dose.« less

  13. Obesity coverage gap: Consumers perceive low coverage for obesity treatments even when workplace wellness programs target BMI.

    PubMed

    Wilson, Elizabeth Ruth; Kyle, Theodore K; Nadglowski, Joseph F; Stanford, Fatima Cody

    2017-02-01

    Evidence-based obesity treatments, such as bariatric surgery, are not considered essential health benefits under the Affordable Care Act. Employer-sponsored wellness programs with incentives based on biometric outcomes are allowed and often used despite mixed evidence regarding their effectiveness. This study examines consumers' perceptions of their coverage for obesity treatments and exposure to workplace wellness programs. A total of 7,378 participants completed an online survey during 2015-2016. Respondents answered questions regarding their health coverage for seven medical services and exposure to employer wellness programs that target weight or body mass index (BMI). Using χ 2 tests, associations between perceptions of exposure to employer wellness programs and coverage for medical services were examined. Differences between survey years were also assessed. Most respondents reported they did not have health coverage for obesity treatments, but more of the respondents with employer wellness programs reported having coverage. Neither the perception of coverage for obesity treatments nor exposure to wellness programs increased between 2015 and 2016. Even when consumers have exposure to employer wellness programs that target BMI, their health insurance often excludes obesity treatments. Given the clinical and cost-effectiveness of such treatments, reducing that coverage gap may mitigate obesity's individual- and population-level effects. © 2017 The Obesity Society.

  14. Seasonal influenza vaccine dose distribution in 195 countries (2004-2013): Little progress in estimated global vaccination coverage.

    PubMed

    Palache, Abraham; Oriol-Mathieu, Valerie; Fino, Mireli; Xydia-Charmanta, Margarita

    2015-10-13

    Seasonal influenza is an important disease which results in 250,000-500,000 annual deaths worldwide. Global targets for vaccination coverage rates (VCRs) in high-risk groups are at least 75% in adults ≥65 years and increased coverage in other risk groups. The International Federation of Pharmaceutical Manufacturers and Associations Influenza Vaccine Supply (IFPMA IVS) International Task Force developed a survey methodology in 2008, to assess the global distribution of influenza vaccine doses as a proxy for VCRs. This paper updates the previous survey results on absolute numbers of influenza vaccine doses distributed between 2004 and 2013 inclusive, and dose distribution rates per 1000 population, and provides a qualitative assessment of the principal enablers and barriers to seasonal influenza vaccination. The two main findings from the quantitative portion of the survey are the continued negative trend for dose distribution in the EURO region and the perpetuation of appreciable differences in scale of dose distribution between WHO regions, with no observed convergence in the rates of doses distributed per 1000 population over time. The main findings from the qualitative portion of the survey were that actively managing the vaccination program in real-time and ensuring political commitment to vaccination are important enablers of vaccination, whereas insufficient access to vaccination and lack of political commitment to seasonal influenza vaccination programs are likely contributing to vaccination target failures. In all regions of the world, seasonal influenza vaccination is underutilized as a public health tool. The survey provides evidence of lost opportunity to protect populations against potentially serious influenza-associated disease. We call on the national and international public health communities to re-evaluate their political commitment to the prevention of the annual influenza disease burden and to develop a systematic approach to improve vaccine

  15. Improving birth dose coverage of hepatitis B vaccine.

    PubMed Central

    Hipgrave, David B.; Maynard, James E.; Biggs, Beverley-Ann

    2006-01-01

    Administration of a birth dose of hepatitis B vaccine (HepB vaccine) to neonates is recommended to prevent mother-to-infant transmission and chronic infection with the hepatitis B virus (HBV). Although manufacturers recommend HepB vaccine distribution and storage at 2-8 degrees C, recognition of the heat stability of hepatitis B surface antigen stimulated research into its use after storage at, or exposure to, ambient or high temperatures. Storage of HepB vaccine at ambient temperatures would enable birth dosing for neonates delivered at home in remote areas or at health posts lacking refrigeration. This article reviews the current evidence on the thermostability of HepB vaccine when stored outside the cold chain (OCC). The reports reviewed show that the vaccines studied were safe and effective whether stored cold or OCC. Field and laboratory data also verifies the retained potency of the vaccine after exposure to heat. The attachment of a highly stable variety of a vaccine vial monitor (measuring cumulative exposure to heat) on many HepB vaccines strongly supports policies allowing their storage OCC, when this will benefit birth dose coverage. We recommend that this strategy be introduced to improve birth dose coverage, especially in rural and remote areas. Concurrent monitoring and evaluation should be undertaken to affirm the safe implementation of this strategy, and assess its cost, feasibility and effect on reducing HBV infection rates. Meanwhile, release of manufacturer data verifying the potency of currently available HepB vaccines after exposure to heat will increase confidence in the use of vaccine vial monitors as a managerial tool during storage of HepB vaccine OCC. PMID:16501717

  16. Target coverage in image-guided stereotactic body radiotherapy of liver tumors.

    PubMed

    Wunderink, Wouter; Méndez Romero, Alejandra; Vásquez Osorio, Eliana M; de Boer, Hans C J; Brandwijk, René P; Levendag, Peter C; Heijmen, Ben J M

    2007-05-01

    To determine the effect of image-guided procedures (with computed tomography [CT] and electronic portal images before each treatment fraction) on target coverage in stereotactic body radiotherapy for liver patients using a stereotactic body frame (SBF) and abdominal compression. CT guidance was used to correct for day-to-day variations in the tumor's mean position in the SBF. By retrospectively evaluating 57 treatment sessions, tumor coverage, as obtained with the clinically applied CT-guided protocol, was compared with that of alternative procedures. The internal target volume-plus (ITV(+)) was introduced to explicitly include uncertainties in tumor delineations resulting from CT-imaging artifacts caused by residual respiratory motion. Tumor coverage was defined as the volume overlap of the ITV(+), derived from a tumor delineated in a treatment CT scan, and the planning target volume. Patient stability in the SBF, after acquisition of the treatment CT scan, was evaluated by measuring the displacement of the bony anatomy in the electronic portal images relative to CT. Application of our clinical protocol (with setup corrections following from manual measurements of the distances between the contours of the planning target volume and the daily clinical target volume in three orthogonal planes, multiple two-dimensional) increased the frequency of nearly full (> or = 99%) ITV(+) coverage to 77% compared with 63% without setup correction. An automated three-dimensional method further improved the frequency to 96%. Patient displacements in the SBF were generally small (< or = 2 mm, 1 standard deviation), but large craniocaudal displacements (maximal 7.2 mm) were occasionally observed. Daily, CT-assisted patient setup may substantially improve tumor coverage, especially with the automated three-dimensional procedure. In the present treatment design, patient stability in the SBF should be verified with portal imaging.

  17. Routine Vaccination Coverage in Northern Nigeria: Results from 40 District-Level Cluster Surveys, 2014-2015.

    PubMed

    Gunnala, Rajni; Ogbuanu, Ikechukwu U; Adegoke, Oluwasegun J; Scobie, Heather M; Uba, Belinda V; Wannemuehler, Kathleen A; Ruiz, Alicia; Elmousaad, Hashim; Ohuabunwo, Chima J; Mustafa, Mahmud; Nguku, Patrick; Waziri, Ndadilnasiya Endie; Vertefeuille, John F

    2016-01-01

    Despite recent success towards controlling poliovirus transmission, Nigeria has struggled to achieve uniformly high routine vaccination coverage. A lack of reliable vaccination coverage data at the operational level makes it challenging to target program improvement. To reliably estimate vaccination coverage, we conducted district-level vaccine coverage surveys using a pre-existing infrastructure of polio technical staff in northern Nigeria. Household-level cluster surveys were conducted in 40 polio high risk districts of Nigeria during 2014-2015. Global positioning system technology and intensive supervision by a pool of qualified technical staff were used to ensure high survey quality. Vaccination status of children aged 12-23 months was documented based on vaccination card or caretaker's recall. District-level coverage estimates were calculated using survey methods. Data from 7,815 children across 40 districts were analyzed. District-level coverage with the third dose of diphtheria-pertussis-tetanus vaccine (DPT3) ranged widely from 1-63%, with all districts having DPT3 coverage below the target of 80%. Median coverage across all districts for each of eight vaccine doses (1 Bacille Calmette-Guérin dose, 3 DPT doses, 3 oral poliovirus vaccine doses, and 1 measles vaccine dose) was <50%. DPT3 coverage by survey was substantially lower (range: 28%-139%) than the 2013 administrative coverage reported among children aged <12 months. Common reported reasons for non-vaccination included lack of knowledge about vaccines and vaccination services (50%) and factors related to access to routine immunization services (15%). Survey results highlighted vaccine coverage gaps that were systematically underestimated by administrative reporting across 40 polio high risk districts in northern Nigeria. Given the limitations of administrative coverage data, our approach to conducting quality district-level coverage surveys and providing data to assess and remediate issues

  18. Oral Cholera Vaccine Coverage during an Outbreak and Humanitarian Crisis, Iraq, 2015.

    PubMed

    Lam, Eugene; Al-Tamimi, Wasan; Russell, Steven Paul; Butt, Muhammad Obaid-Ul Islam; Blanton, Curtis; Musani, Altaf Sadrudin; Date, Kashmira

    2017-01-01

    During November-December 2015, as part of the 2015 cholera outbreak response in Iraq, the Iraqi Ministry of Health targeted ≈255,000 displaced persons >1 year of age with 2 doses of oral cholera vaccine (OCV). All persons who received vaccines were living in selected refugee camps, internally displaced persons camps, and collective centers. We conducted a multistage cluster survey to obtain OCV coverage estimates in 10 governorates that were targeted during the campaign. In total, 1,226 household and 5,007 individual interviews were conducted. Overall, 2-dose OCV coverage in the targeted camps was 87% (95% CI 85%-89%). Two-dose OCV coverage in the 3 northern governorates (91%; 95% CI 87%-94%) was higher than that in the 7 southern and central governorates (80%; 95% CI 77%-82%). The experience in Iraq demonstrates that OCV campaigns can be successfully implemented as part of a comprehensive response to cholera outbreaks among high-risk populations in conflict settings.

  19. SWATHtoMRM: Development of High-Coverage Targeted Metabolomics Method Using SWATH Technology for Biomarker Discovery.

    PubMed

    Zha, Haihong; Cai, Yuping; Yin, Yandong; Wang, Zhuozhong; Li, Kang; Zhu, Zheng-Jiang

    2018-03-20

    The complexity of metabolome presents a great analytical challenge for quantitative metabolite profiling, and restricts the application of metabolomics in biomarker discovery. Targeted metabolomics using multiple-reaction monitoring (MRM) technique has excellent capability for quantitative analysis, but suffers from the limited metabolite coverage. To address this challenge, we developed a new strategy, namely, SWATHtoMRM, which utilizes the broad coverage of SWATH-MS technology to develop high-coverage targeted metabolomics method. Specifically, SWATH-MS technique was first utilized to untargeted profile one pooled biological sample and to acquire the MS 2 spectra for all metabolites. Then, SWATHtoMRM was used to extract the large-scale MRM transitions for targeted analysis with coverage as high as 1000-2000 metabolites. Then, we demonstrated the advantages of SWATHtoMRM method in quantitative analysis such as coverage, reproducibility, sensitivity, and dynamic range. Finally, we applied our SWATHtoMRM approach to discover potential metabolite biomarkers for colorectal cancer (CRC) diagnosis. A high-coverage targeted metabolomics method with 1303 metabolites in one injection was developed to profile colorectal cancer tissues from CRC patients. A total of 20 potential metabolite biomarkers were discovered and validated for CRC diagnosis. In plasma samples from CRC patients, 17 out of 20 potential biomarkers were further validated to be associated with tumor resection, which may have a great potential in assessing the prognosis of CRC patients after tumor resection. Together, the SWATHtoMRM strategy provides a new way to develop high-coverage targeted metabolomics method, and facilitates the application of targeted metabolomics in disease biomarker discovery. The SWATHtoMRM program is freely available on the Internet ( http://www.zhulab.cn/software.php ).

  20. Survey of distribution of seasonal influenza vaccine doses in 201 countries (2004-2015): The 2003 World Health Assembly resolution on seasonal influenza vaccination coverage and the 2009 influenza pandemic have had very little impact on improving influenza control and pandemic preparedness.

    PubMed

    Palache, A; Abelin, A; Hollingsworth, R; Cracknell, W; Jacobs, C; Tsai, T; Barbosa, P

    2017-08-24

    There is no global monitoring system for influenza vaccination coverage, making it difficult to assess progress towards the 2003 World Health Assembly (WHA) vaccination coverage target. In 2008, the IFPMA Influenza Vaccine Supply International Task Force (IVS) developed a survey method to assess the global distribution of influenza vaccine doses as a proxy for vaccination coverage rates. The latest dose distribution data for 2014 and 2015 was used to update previous analyses. Data were confidentially collected and aggregated by the IFPMA Secretariat, and combined with previous IFPMA IVS survey data (2004-2013). Data were available from 201 countries over the 2004-2015 period. A "hurdle" rate was defined as the number of doses required to reach 15.9% of the population in 2008. Overall, the number of distributed doses progressively increased between 2004 and 2011, driven by a 150% increase in AMRO, then plateaued. One percent fewer doses were distributed in 2015 than in 2011. Twenty-three countries were above the hurdle rate in 2015, compared to 15 in 2004, but distribution was highly uneven in and across all WHO regions. Three WHO regions (AMRO, EURO and WPRO) accounted for about 95% of doses distributed. But in EURO and WPRO, distribution rates in 2015 were only marginally higher than in 2004, and in EURO there was an overall downward trend in dose distribution. The vast majority of countries cannot meet the 2003WHA coverage targets and are inadequately prepared for a global influenza pandemic. With only 5% of influenza vaccine doses being distributed to 50% of the world's population, there is urgency to redress the gross inequities in disease prevention and in pandemic preparedness. The 2003WHA resolution must be reviewed and revised and a call issued for the renewed commitment of Member States to influenza vaccination coverage targets. Copyright © 2017. Published by Elsevier Ltd.

  1. Combined photon-electron beams in the treatment of the supraclavicular lymph nodes in breast cancer: A novel technique that achieves adequate coverage while reducing lung dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salem, Ahmed, E-mail: ahmed.salem@doctors.org.uk; Mohamad, Issa; Dayyat, Abdulmajeed

    2015-10-01

    Radiation pneumonitis is a well-documented side effect of radiation therapy for breast cancer. The purpose of this study was to compare combined photon-electron, photon-only, and electron-only plans in the radiation treatment of the supraclavicular lymph nodes. In total, 13 patients requiring chest wall and supraclavicular nodal irradiation were planned retrospectively using combined photon-electron, photon-only, and electron-only supraclavicular beams. A dose of 50 Gy over 25 fractions was prescribed. Chest wall irradiation parameters were fixed for all plans. The goal of this planning effort was to cover 95% of the supraclavicular clinical target volume (CTV) with 95% of the prescribed dosemore » and to minimize the volume receiving ≥ 105% of the dose. Comparative end points were supraclavicular CTV coverage (volume covered by the 95% isodose line), hotspot volume, maximum radiation dose, contralateral breast dose, mean total lung dose, total lung volume percentage receiving at least 20 Gy (V{sub 20} {sub Gy}), heart volume percentage receiving at least 25 Gy (V{sub 25} {sub Gy}). Electron and photon energies ranged from 8 to 18 MeV and 4 to 6 MV, respectively. The ratio of photon-to-electron fractions in combined beams ranged from 5:20 to 15:10. Supraclavicular nodal coverage was highest in photon-only (mean = 96.2 ± 3.5%) followed closely by combined photon-electron (mean = 94.2 ± 2.5%) and lowest in electron-only plans (mean = 81.7 ± 14.8%, p < 0.001). The volume of tissue receiving ≥ 105% of the prescription dose was higher in the electron-only (mean = 69.7 ± 56.1 cm{sup 3}) as opposed to combined photon-electron (mean = 50.8 ± 40.9 cm{sup 3}) and photon-only beams (mean = 32.2 ± 28.1 cm{sup 3}, p = 0.114). Heart V{sub 25} {sub Gy} was not statistically different among the plans (p = 0.999). Total lung V{sub 20} {sub Gy} was lowest in electron-only (mean = 10.9 ± 2.3%) followed by combined photon-electron (mean = 13.8 ± 2.3%) and highest in

  2. SU-E-T-333: Dosimetric Impact of Rotational Error On the Target Coverage in IMPT Lung Cancer Plans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rana, S; Zheng, Y

    2015-06-15

    Purpose: The main purpose of this study was to investigate the impact of rotational (yaw, roll, and pitch) error on the planning target volume (PTV) coverage in lung cancer plans generated by intensity modulated proton therapy (IMPT). Methods: In this retrospective study, computed tomography (CT) dataset of previously treated lung case was used. IMPT plan were generated on the original CT dataset using left-lateral (LL) and posterior-anterior (PA) beams for a total dose of 74 Gy[RBE] with 2 Gy[RBE] per fraction. In order to investigate the dosimetric impact of rotational error, 12 new CT datasets were generated by re-sampling themore » original CT dataset for rotational (roll, yaw, and pitch) angles ranged from −5° to +5°, with an increment of 2.5°. A total of 12 new IMPT plans were generated based on the re-sampled CT datasets using beam parameters identical to the ones in the original IMPT plan. All treatment plans were generated in XiO treatment planning system. The PTV coverage (i.e., dose received by 95% of the PTV volume, D95) in new IMPT plans were then compared with the PTV coverage in the original IMPT plan. Results: Rotational errors caused the reduction in the PTV coverage in all 12 new IMPT plans when compared to the original IMPT lung plan. Specifically, the PTV coverage was reduced by 4.94% to 50.51% for yaw, by 4.04% to 23.74% for roll, and by 5.21% to 46.88% for pitch errors. Conclusion: Unacceptable dosimetric results were observed in new IMPT plans as the PTV coverage was reduced by up to 26.87% and 50.51% for rotational error of 2.5° and 5°, respectively. Further investigation is underway in evaluating the PTV coverage loss in the IMPT lung cancer plans for smaller rotational angle change.« less

  3. Routine Vaccination Coverage in Northern Nigeria: Results from 40 District-Level Cluster Surveys, 2014-2015

    PubMed Central

    Ogbuanu, Ikechukwu U.; Adegoke, Oluwasegun J.; Scobie, Heather M.; Uba, Belinda V.; Wannemuehler, Kathleen A.; Ruiz, Alicia; Elmousaad, Hashim; Ohuabunwo, Chima J.; Mustafa, Mahmud; Nguku, Patrick; Waziri, Ndadilnasiya Endie; Vertefeuille, John F.

    2016-01-01

    Background Despite recent success towards controlling poliovirus transmission, Nigeria has struggled to achieve uniformly high routine vaccination coverage. A lack of reliable vaccination coverage data at the operational level makes it challenging to target program improvement. To reliably estimate vaccination coverage, we conducted district-level vaccine coverage surveys using a pre-existing infrastructure of polio technical staff in northern Nigeria. Methods Household-level cluster surveys were conducted in 40 polio high risk districts of Nigeria during 2014–2015. Global positioning system technology and intensive supervision by a pool of qualified technical staff were used to ensure high survey quality. Vaccination status of children aged 12–23 months was documented based on vaccination card or caretaker’s recall. District-level coverage estimates were calculated using survey methods. Results Data from 7,815 children across 40 districts were analyzed. District-level coverage with the third dose of diphtheria-pertussis-tetanus vaccine (DPT3) ranged widely from 1–63%, with all districts having DPT3 coverage below the target of 80%. Median coverage across all districts for each of eight vaccine doses (1 Bacille Calmette-Guérin dose, 3 DPT doses, 3 oral poliovirus vaccine doses, and 1 measles vaccine dose) was <50%. DPT3 coverage by survey was substantially lower (range: 28%–139%) than the 2013 administrative coverage reported among children aged <12 months. Common reported reasons for non-vaccination included lack of knowledge about vaccines and vaccination services (50%) and factors related to access to routine immunization services (15%). Conclusions Survey results highlighted vaccine coverage gaps that were systematically underestimated by administrative reporting across 40 polio high risk districts in northern Nigeria. Given the limitations of administrative coverage data, our approach to conducting quality district-level coverage surveys and

  4. SU-F-T-563: Delivered Dose Reconstruction of Moving Targets for Gated Volumetric Modulated Arc Therapy (VMAT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chung, H; Cho, S; Jeong, C

    2016-06-15

    Purpose: Actual delivered dose of moving tumors treated with gated volumetric arc therapy (VMAT) may significantly differ from the planned dose assuming static target. In this study, we developed a method which reconstructs actual delivered dose distribution of moving target by taking into account both tumor motion and dynamic beam delivery of gated VMAT, and applied to abdominal tumors. Methods: Fifteen dual-arc VMAT plans (Eclipse, Varian Medical Systems) for 5 lung, 5 pancreatic, and 5 liver cancer patients treated with gated VMAT stereotactic body radiotherapy (SBRT) were studied. For reconstruction of the delivered dose distribution, we divided each original arcmore » beam into control-point-wise sub-beams, and applied beam isocenter shifting to each sub-beam to reflect the tumor motion. The tumor positions as a function of beam delivery were estimated by synchronizing the beam delivery with the respiratory signal which acquired during treatment. For this purpose, an in-house program (MATLAB, Mathworks) was developed to convert the original DICOM plan data into motion-involved treatment plan. The motion-involved DICOM plan was imported into Eclipse for dose calculation. The reconstructed delivered dose was compared to the plan dose using the dose coverage of gross tumor volume (GTV) and dose distribution of organs at risk (OAR). Results: The mean GTV dose coverage difference between the reconstructed delivered dose and the plan dose was 0.2 % in lung and pancreas cases, and no difference in liver cases. Mean D1000cc of ipsilateral lungs was reduced (0.8 ± 1.4cGy). Conclusion: We successfully developed a method of delivered dose reconstruction taking into account both respiratory tumor motion and dynamic beam delivery, and applied it to abdominal tumors treated with gated VAMT. No significant deterioration of delivered dose distribution indicates that interplay effect would be minimal even in the case of gated SBRT. This work was supported by the National

  5. Assessing Coverage of Population-Based and Targeted Fortification Programs with the Use of the Fortification Assessment Coverage Toolkit (FACT): Background, Toolkit Development, and Supplement Overview.

    PubMed

    Friesen, Valerie M; Aaron, Grant J; Myatt, Mark; Neufeld, Lynnette M

    2017-05-01

    Food fortification is a widely used approach to increase micronutrient intake in the diet. High coverage is essential for achieving impact. Data on coverage is limited in many countries, and tools to assess coverage of fortification programs have not been standardized. In 2013, the Global Alliance for Improved Nutrition developed the Fortification Assessment Coverage Toolkit (FACT) to carry out coverage assessments in both population-based (i.e., staple foods and/or condiments) and targeted (e.g., infant and young child) fortification programs. The toolkit was designed to generate evidence on program coverage and the use of fortified foods to provide timely and programmatically relevant information for decision making. This supplement presents results from FACT surveys that assessed the coverage of population-based and targeted food fortification programs across 14 countries. It then discusses the policy and program implications of the findings for the potential for impact and program improvement.

  6. DMLC tracking and gating can improve dose coverage for prostate VMAT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colvill, E.; Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, NSW 2065; School of Physics, University of Sydney, NSW 2006

    2014-09-15

    {sub 65%} the range was −61% to 26% from planned. The application of tracking decreased the maximum rectum and bladder V{sub 65%} difference to 6% and 4%, respectively. Conclusions: For the first time, the dosimetric impact of DMLC tracking and gating to account for intrafraction motion during prostate radiotherapy has been assessed and compared with no motion correction. Without motion correction intrafraction prostate motion can result in a significant decrease in target dose coverage for a small number of individual fractions. This is unlikely to effect the overall treatment for most patients undergoing conventionally fractionated treatments. Both DMLC tracking and gating demonstrate dose distributions for all assessed fractions that are robust to intrafraction motion.« less

  7. A novel dose-based positioning method for CT image-guided proton therapy

    PubMed Central

    Cheung, Joey P.; Park, Peter C.; Court, Laurence E.; Ronald Zhu, X.; Kudchadker, Rajat J.; Frank, Steven J.; Dong, Lei

    2013-01-01

    Purpose: Proton dose distributions can potentially be altered by anatomical changes in the beam path despite perfect target alignment using traditional image guidance methods. In this simulation study, the authors explored the use of dosimetric factors instead of only anatomy to set up patients for proton therapy using in-room volumetric computed tomographic (CT) images. Methods: To simulate patient anatomy in a free-breathing treatment condition, weekly time-averaged four-dimensional CT data near the end of treatment for 15 lung cancer patients were used in this study for a dose-based isocenter shift method to correct dosimetric deviations without replanning. The isocenter shift was obtained using the traditional anatomy-based image guidance method as the starting position. Subsequent isocenter shifts were established based on dosimetric criteria using a fast dose approximation method. For each isocenter shift, doses were calculated every 2 mm up to ±8 mm in each direction. The optimal dose alignment was obtained by imposing a target coverage constraint that at least 99% of the target would receive at least 95% of the prescribed dose and by minimizing the mean dose to the ipsilateral lung. Results: The authors found that 7 of 15 plans did not meet the target coverage constraint when using only the anatomy-based alignment. After the authors applied dose-based alignment, all met the target coverage constraint. For all but one case in which the target dose was met using both anatomy-based and dose-based alignment, the latter method was able to improve normal tissue sparing. Conclusions: The authors demonstrated that a dose-based adjustment to the isocenter can improve target coverage and/or reduce dose to nearby normal tissue. PMID:23635262

  8. NSW Annual Immunisation Coverage Report, 2009.

    PubMed

    Hull, Brynley; Dey, Aditi; Mahajan, Deepika; Campbell-Lloyd, Sue; Menzies, Robert I; McIntyre, Peter B

    2010-01-01

    This is the first in a series of annual immunisation coverage reports that document trends in NSW for a range of standard measures derived from Australian Childhood Immunisation Register data, including overall coverage at standard age milestones and for individual vaccines. This report includes data up to and including 2009. Data from the Australian Childhood Immunisation Register, the NSW Health Survey and the NSW School Immunisation Program were used to calculate various measures of population coverage relating to childhood vaccines, adult influenza and pneumococcal vaccines and adolescent vaccination, respectively. Immunise Australia Program targets have been reached for children at 12 and 24 months of age but not for children at 5 years of age. Delayed receipt of vaccines is an issue for vaccines recommended for Aboriginal children. Pneumococcal vaccination in the elderly has been steadily rising, although it has remained lower than the influenza coverage estimates. For adolescents, there is better coverage for the first and second doses of human papillomavirus vaccine and the dose of dTpa than for varicella. This comprehensive analysis provides important baseline data for NSW against which future reports can be compared to monitor progress in improving immunisation coverage. Immunisation at the earliest appropriate age should be a public health goal for countries such as Australia where high levels of vaccine coverage at milestone ages have been achieved.

  9. SU-G-BRA-16: Target Dose Comparison for Dynamic MLC Tracking and Mid- Ventilation Planning in Lung Radiotherapy Subject to Intrafractional Baseline Drifts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Menten, MJ; Fast, MF; Nill, S

    Purpose: Lung tumor motion during radiotherapy can be accounted for by expanded treatment margins, for example using a mid-ventilation planning approach, or by localizing the tumor in real-time and adapting the treatment beam with multileaf collimator (MLC) tracking. This study evaluates the effect of intrafractional changes in the average tumor position (baseline drifts) on these two treatment techniques. Methods: Lung stereotactic treatment plans (9-beam IMRT, 54Gy/3 fractions, mean treatment time: 9.63min) were generated for three patients: either for delivery with MLC tracking (isotropic GTV-to-PTV margin: 2.6mm) or planned with a mid-ventilation approach and delivered without online motion compensation (GTV-to-PTV margin:more » 4.4-6.3mm). Delivery to a breathing patient was simulated using DynaTrack, our in-house tracking and delivery software. Baseline drifts in cranial and posterior direction were simulated at a rate of 0.5, 1.0 or 1.5mm/min. For dose reconstruction, the corresponding 4DCT phase was selected for each time point of the delivery. Baseline drifts were accounted for by rigidly shifting the CT to ensure correct relative beam-to-target positioning. Afterwards, the doses delivered to each 4DCT phase were accumulated deformably on the mid-ventilation phase using research RayStation v4.6 and dose coverage of the GTV was evaluated. Results: When using the mid-ventilation planning approach, dose coverage of the tumor deteriorated substantially in the presence of baseline drifts. The reduction in D98% coverage of the GTV in a single fraction ranged from 0.4-1.2, 0.6-3.3 and 4.5-6.2Gy, respectively, for the different drift rates. With MLC tracking the GTV D98% coverage remained unchanged (+/− 0.1Gy) regardless of drift. Conclusion: Intrafractional baseline drifts reduce the tumor dose in treatments based on mid-ventilation planning. In rare, large target baseline drifts tumor dose coverage may drop below the prescription, potentially affecting

  10. Quantitatively Excessive Normal Tissue Toxicity and Poor Target Coverage in Postoperative Lung Cancer Radiotherapy Meta-analysis.

    PubMed

    Abuodeh, Yazan; Naghavi, Arash O; Echevarria, Michelle; DeMarco, MaryLou; Tonner, Brian; Feygelman, Vladimir; Stevens, Craig W; Perez, Bradford A; Dilling, Thomas J

    2018-01-01

    A previous meta-analysis (MA) found postoperative radiotherapy (PORT) in lung cancer patients to be detrimental in N0/N1 patients and equivocal in the N2 setting. We hypothesized that treatment plans generated using MA protocols had worse dosimetric outcomes compared to modern plans. We retrieved plans for 13 patients who received PORT with modern planning. A plan was recreated for each patient using the 8 protocols included in MA. Dosimetric values were then compared between the modern and simulated MA plans. A total of 104 MA plans were generated. Median prescribed dose was 50.4 (range, 50-60) Gy in the modern plans and 53.2 (30-60) Gy in the MA protocols. Median planning volume coverage was 96% (93%-100%) in the modern plans, versus 58% (0%-100%) in the MA plans (P < .001). Internal target volume coverage was 100% (99%-100%) versus 65% (0%-100%), respectively (P < .001). Organs at risk received the following doses: spinal cord maximum dose, 36.8 (4.6-50.4) Gy versus 46.8 (2.9-74.0) Gy (P < .001); esophageal mean dose, 22.9 (5.5-35) Gy versus 30.5 (11.1-52.5) Gy (P = .003); heart V30 (percentage of volume of an organ receiving at least a dose of 30 Gy), 16% (0%-45%) versus 35% (0%-79%) (P = .047); mean lung dose, 12.4 (3.4-24.3) Gy versus 14.8 (4.1-27.4) Gy (P = .008); and lung V20, 18% (4%-34%) versus 25% (8%-67%) (P = .023). We quantitatively confirm the inferiority of the techniques used in the PORT MA. Our analysis showed a lower therapeutic ratio in the MA plans, which may explain the poor outcomes in the MA. The findings of the MA are not relevant in the era of modern treatment planning. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. A radiotherapy technique to limit dose to neural progenitor cell niches without compromising tumor coverage

    PubMed Central

    Redmond, Kristin J.; Achanta, Pragathi; Grossman, Stuart A.; Armour, Michael; Reyes, Juvenal; Kleinberg, Lawrence; Tryggestad, Erik; Quinones-Hinojosa, Alfredo

    2015-01-01

    Radiation therapy (RT) for brain tumors is associated with neurocognitive toxicity which may be a result of damage to neural progenitor cells (NPCs). We present a novel technique to limit the radiation dose to NPC without compromising tumor coverage. A study was performed in mice to examine the rationale and another was conducted in humans to determine its feasibility. C57BL/6 mice received localized radiation using a dedicated animal irradiation system with on-board CT imaging with either: (1) Radiation which spared NPC containing regions; (2) Radiation which did not spare these niches; or (3) Sham irradiation. Mice were sacrificed 24 h later and the brains were processed for immunohistochemical Ki-67 staining. For the human component of the study, 33 patients with primary brain tumors were evaluated. Two intensity modulated radiotherapy (IMRT) plans were retrospectively compared: a standard clinical plan and a plan which spares NPC regions while maintaining the same dose coverage of the tumor. The change in radiation dose to the contralateral NPC-containing regions was recorded. In the mouse model, non-NPC-sparing radiation treatment resulted in a significant decrease in the number of Ki67+ cells in dentate gyrus (DG) (P = 0.008) and subventricular zone (SVZ) (P = 0.005) compared to NPC-sparing radiation treatment. In NPC-sparing clinical plans, NPC regions received significantly lower radiation dose with no clinically relevant changes in tumor coverage. This novel radiation technique should significantly reduce radiation doses to NPC containing regions of the brain which may reduce neurocognitive deficits following RT for brain tumors. PMID:21327710

  12. Comparison of Mass Azithromycin Coverage Targets of Children in Niger: A Cluster-Randomized Trachoma Trial.

    PubMed

    Oldenburg, Catherine E; Amza, Abdou; Kadri, Boubacar; Nassirou, Beido; Cotter, Sun Y; Stoller, Nicole E; West, Sheila K; Bailey, Robin L; Porco, Travis C; Gaynor, Bruce D; Keenan, Jeremy D; Lietman, Thomas M

    2018-02-01

    Repeated oral azithromycin distribution targeted only to children has proven effective in reducing the ocular Chlamydia that causes trachoma. Here, we assess whether an enhanced coverage target of at least 90% of children is superior to the World Health Organization recommendation of at least 80%. Twenty-four trachoma-endemic communities in Matamèye, Niger, were randomized to a single day of azithromycin distribution aiming for at least 80% coverage or up to 4 days of treatment and > 90% coverage of children under age 12. All distributions were biannual. Children < 5 years of age and adults > 15 years were monitored for ocular Chlamydia infection by polymerase chain reaction every 6 months for 36 months in children and at baseline and 36 months in adults. Ocular Chlamydia prevalence in children decreased from 24.9% (95% confidence interval [CI] 15.9-33.8%) to 4.4% (95% CI 0.6-8.2%, P < 0.001) at 36 months in the standard coverage arm and from 15.6% (95% CI 10.0-21.2%) to 3.3% (95% CI 1.0-5.5%; P < 0.001) in the enhanced coverage arm. Enhanced coverage reduced ocular Chlamydia prevalence in children more quickly over time compared with standard ( P = 0.04). There was no difference between arms at 36 months in children (2.4% lower with enhanced coverage, 95% CI 7.7-12.5%; P = 0.60). No infection was detected in adults at 36 months. Increasing antibiotic coverage among children from 80% to 90% may yield only short term improvements for trachoma control programs. Targeting treatment to children alone may be sufficient for trachoma control in this setting.

  13. Vaccination Coverage Disparities Between Foreign-Born and U.S.-Born Children Aged 19-35 Months, United States, 2010-2012.

    PubMed

    Varan, Aiden K; Rodriguez-Lainz, Alfonso; Hill, Holly A; Elam-Evans, Laurie D; Yankey, David; Li, Qian

    2017-08-01

    Healthy People 2020 targets high vaccination coverage among children. Although reductions in coverage disparities by race/ethnicity have been described, data by nativity are limited. The National Immunization Survey is a random-digit-dialed telephone survey that estimates vaccination coverage among U.S. children aged 19-35 months. We assessed coverage among 52,441 children from pooled 2010-2012 data for individual vaccines and the combined 4:3:1:3*:3:1:4 series (which includes ≥4 doses of diphtheria, tetanus, and acellular pertussis vaccine/diphtheria and tetanus toxoids vaccine/diphtheria, tetanus toxoids, and pertussis vaccine, ≥3 doses of poliovirus vaccine, ≥1 dose of measles-containing vaccine, ≥3 or ≥4 doses of Haemophilus influenzae type b vaccine (depending on product type of vaccine; denoted as 3* in the series name), ≥3 doses of hepatitis B vaccine, ≥1 dose of varicella vaccine, and ≥4 doses of pneumococcal conjugate vaccine). Coverage estimates controlling for sociodemographic factors and multivariable logistic regression modeling for 4:3:1:3*:3:1:4 series completion are presented. Significantly lower coverage among foreign-born children was detected for DTaP, hepatitis A, hepatitis B, Hib, pneumococcal conjugate, and rotavirus vaccines, and for the combined series. Series completion disparities persisted after control for demographic, access-to-care, poverty, and language effects. Substantial and potentially widening disparities in vaccination coverage exist among foreign-born children. Improved immunization strategies targeting this population and continued vaccination coverage monitoring by nativity are needed.

  14. Assessment of on-time vaccination coverage in population subgroups: A record linkage cohort study.

    PubMed

    Moore, Hannah C; Fathima, Parveen; Gidding, Heather F; de Klerk, Nicholas; Liu, Bette; Sheppeard, Vicky; Effler, Paul V; Snelling, Thomas L; McIntyre, Peter; Blyth, Christopher C

    2018-05-31

    Reported infant vaccination coverage at age 12 months in Australia is >90%. On-time coverage of the 2-4-6 month schedule and coverage in specific populations is rarely reported. We conducted a population-based cohort study of 1.9 million Australian births, 1996-2012, combining individual birth and perinatal records with immunisation records through probabilistic linkage. We assessed on-time coverage across 13 demographic and perinatal characteristics of diphtheria-tetanus-pertussis vaccines (DTP) defined as vaccination 14 days prior to the scheduled due date, to 30 days afterwards. On-time DTP vaccination coverage in non-Aboriginal infants was 88.1% for the 2-month dose, 82.0% for 4-month dose, and 76.7% for 6-month dose; 3-dose coverage was 91.3% when assessed at 12 months. On-time DTP coverage for Aboriginal infants was 77.0%, 66.5%, and 61.0% for the 2-4-6 month dose; 3-dose coverage at 12 months was 79.3%. Appreciable differences in on-time coverage were observed across population subgroups. On-time coverage in non-Aboriginal infants born to mothers with ≥3 previous pregnancies was 62.5% for the 6-month dose (47.9% for Aboriginal infants); up to 23.5 percentage points lower than for first-borns. Infants born to mothers who smoked during pregnancy had coverage 8.7-10.3 percentage points lower than infants born to non-smoking mothers for the 4- and 6-month dose. A linear relationship was apparent between increasing socio-economic disadvantage and decreasing on-time coverage. On-time coverage of the 2-4-6 month schedule is only 50-60% across specific population subgroups representing a significant avoidable public health risk. Aboriginal infants, multiparous mothers, and those who are socio-economically disadvantaged are key groups most likely to benefit from targeted programs addressing vaccine timeliness. Copyright © 2018. Published by Elsevier Ltd.

  15. Vaccination coverage among children in kindergarten - United States, 2012-13 school year.

    PubMed

    2013-08-02

    State and local school vaccination requirements are implemented to maintain high vaccination coverage and minimize the risk from vaccine preventable diseases. To assess school vaccination coverage and exemptions, CDC annually analyzes school vaccination coverage data from federally funded immunization programs. These awardees include 50 states and the District of Columbia (DC), five cities, and eight U.S.-affiliated jurisdictions. This report summarizes vaccination coverage from 48 states and DC and exemption rates from 49 states and DC for children entering kindergarten for the 2012-13 school year. Forty-eight states and DC reported vaccination coverage, with medians of 94.5% for 2 doses of measles, mumps, and rubella (MMR) vaccine; 95.1% for local requirements for diphtheria, tetanus toxoid, and acellular pertussis (DTaP) vaccination; and 93.8% for 2 doses of varicella vaccine among awardees with a 2-dose requirement. Forty-nine states and DC reported exemption rates, with the median total of 1.8%. Although school entry coverage for most awardees was at or near national Healthy People 2020 targets of maintaining 95% vaccination coverage levels for 2 doses of MMR vaccine, 4 doses of DTaP† vaccine, and 2 doses of varicella vaccine, low vaccination and high exemption levels can cluster within communities, increasing the risk for disease. Reports to CDC are aggregated at the state level; however, local reporting of school vaccination coverage might be accessible by awardees. These local-level data can be used to create evidence-based health communication strategies to help parents understand the risks for vaccine-preventable diseases and the benefits of vaccinations to the health of their children and other kindergarteners.

  16. Vaccination coverage among children in kindergarten - United States, 2013-14 school year.

    PubMed

    Seither, Ranee; Masalovich, Svetlana; Knighton, Cynthia L; Mellerson, Jenelle; Singleton, James A; Greby, Stacie M

    2014-10-17

    State and local vaccination requirements for school entry are implemented to maintain high vaccination coverage and protect schoolchildren from vaccine-preventable diseases. Each year, to assess state and national vaccination coverage and exemption levels among kindergartners, CDC analyzes school vaccination data collected by federally funded state, local, and territorial immunization programs. This report describes vaccination coverage in 49 states and the District of Columbia (DC) and vaccination exemption rates in 46 states and DC for children enrolled in kindergarten during the 2013-14 school year. Median vaccination coverage was 94.7% for 2 doses of measles, mumps, and rubella (MMR) vaccine; 95.0% for varying local requirements for diphtheria, tetanus toxoid, and acellular pertussis (DTaP) vaccine; and 93.3% for 2 doses of varicella vaccine among those states with a 2-dose requirement. The median total exemption rate was 1.8%. High exemption levels and suboptimal vaccination coverage leave children vulnerable to vaccine-preventable diseases. Although vaccination coverage among kindergartners for the majority of reporting states was at or near the 95% national Healthy People 2020 targets for 4 doses of DTaP, 2 doses of MMR, and 2 doses of varicella vaccine, low vaccination coverage and high exemption levels can cluster within communities. Immunization programs might have access to school vaccination coverage and exemption rates at a local level for counties, school districts, or schools that can identify areas where children are more vulnerable to vaccine-preventable diseases. Health promotion efforts in these local areas can be used to help parents understand the risks for vaccine-preventable diseases and the protection that vaccinations provide to their children.

  17. National, State, and Selected Local Area Vaccination Coverage Among Children Aged 19-35 Months - United States, 2014.

    PubMed

    Hill, Holly A; Elam-Evans, Laurie D; Yankey, David; Singleton, James A; Kolasa, Maureen

    2015-08-28

    The reduction in morbidity and mortality associated with vaccine-preventable diseases in the United States has been described as one of the 10 greatest public health achievements of the first decade of the 21st century. A recent analysis concluded that routine childhood vaccination will prevent 322 million cases of disease and about 732,000 early deaths among children born during 1994-2013, for a net societal cost savings of $1.38 trillion. The National Immunization Survey (NIS) has monitored vaccination coverage among U.S. children aged 19-35 months since 1994. This report presents national, regional, state, and selected local area vaccination coverage estimates for children born from January 2011 through May 2013, based on data from the 2014 NIS. For most vaccinations, there was no significant change in coverage between 2013 and 2014. The exception was hepatitis A vaccine (HepA), for which increases were observed in coverage with both ≥1 and ≥2 doses. As in previous years, <1% of children received no vaccinations. National coverage estimates indicate that the Healthy People 2020 target* of 90% was met for ≥3 doses of poliovirus vaccine (93.3%), ≥1 dose of measles, mumps, and rubella vaccine (MMR) (91.5%), ≥3 doses of hepatitis B vaccine (HepB) (91.6%), and ≥1 dose of varicella vaccine (91.0%). Coverage was below target for ≥4 doses of diphtheria, tetanus, and acellular pertussis vaccine (DTaP), the full series of Haemophilus influenzae type b (Hib) vaccine, hepatitis B (HepB) birth dose,† ≥4 doses pneumococcal conjugate vaccine (PCV), ≥2 doses of HepA, the full series of rotavirus vaccine, and the combined vaccine series.§ Examination of coverage by child's race/ethnicity revealed lower estimated coverage among non-Hispanic black children compared with non-Hispanic white children for several vaccinations, including DTaP, the full series of Hib, PCV, rotavirus vaccine, and the combined series. Children from households classified as below the

  18. Comparison of inflation of third dose diphtheria tetanus pertussis (DTP3) administrative coverage to other vaccine antigens.

    PubMed

    Dolan, Samantha B; MacNeil, Adam

    2017-06-14

    Third dose diphtheria tetanus pertussis (DTP3) administrative coverage is a commonly used indicator for immunization program performance, although studies have demonstrated data quality issues with administrative DTP3 coverage. It is possible that administrative coverage for DTP3 may be inflated more than for other antigens. To examine this, theory, we compiled immunization coverage estimates from recent country surveys (n=71) and paired these with corresponding administrative coverage estimates, by country and cohort year, for DTP3 and 4 other antigens. Median administrative coverage was higher than survey estimates of coverage for all antigens (median differences from 26 to 30%), however this difference was similar for DTP3 as for all other antigens. These findings were consistent when countries were stratified by income level and eligibility for Gavi funding. Our findings demonstrate that while country administrative coverage estimates tend to be higher than survey estimates, DTP3 administrative coverage is not inflated more than other antigens. Published by Elsevier Ltd.

  19. Measles transmission following the tsunami in a population with a high one-dose vaccination coverage, Tamil Nadu, India 2004-2005.

    PubMed

    Mohan, Arumugam; Murhekar, Manoj V; Wairgkar, Niteen S; Hutin, Yvan J; Gupte, Mohan D

    2006-09-19

    On 26 December 2004, a tsunami struck the coast of the state of Tamil Nadu, India, where one-dose measles coverage exceeded 95%. On 29 December, supplemental measles immunization activities targeted children 6 to 60 months of age in affected villages. On 30 December, Cuddalore, a tsunami-affected district in Tamil Nadu reported a cluster of measles cases. We investigated this cluster to estimate the magnitude of the problem and to propose recommendations for control. We received notification of WHO-defined measles cases through stimulated passive surveillance. We collected information regarding date of onset, age, sex, vaccination status and residence. We collected samples for IgM antibodies and genotype studies. We modeled the accumulation of susceptible individuals over the time on the basis of vaccination coverage, vaccine efficacy and birth rate. We identified 101 measles cases and detected IgM antibodies against measles virus in eight of 11 sera. Cases were reported from tsunami-affected (n = 71) and unaffected villages (n = 30) with attack rates of 1.3 and 1.7 per 1000, respectively. 42% of cases in tsunami-affected villages had an onset date within 14 days of the tsunami. The median ages of case-patients in tsunami-affected and un-affected areas were 54 months and 60 months respectively (p = 0.471). 36% of cases from tsunami-affected areas were above 60 months of age. Phylogenetic analyses indicated that the sequences of virus belonged to genotype D8 that circulated in Tamil Nadu. Measles virus circulated in Cuddalore district following the tsunami, although there was no association between the two events. Transmission despite high one-dose vaccination coverage pointed to the limitations of this vaccination strategy. A second opportunity for measles immunization may help reducing measles mortality and morbidity in such areas. Children from 6 month to 14 years of age must be targeted for supplemental immunization during complex emergencies.

  20. Radiation Dose Reduction by Indication-Directed Focused z-Direction Coverage for Neck CT.

    PubMed

    Parikh, A K; Shah, C C

    2016-06-01

    The American College of Radiology-American Society of Neuroradiology-Society for Pediatric Radiology Practice Parameter for a neck CT suggests that coverage should be from the sella to the aortic arch. It also recommends using CT scans judiciously to achieve the clinical objective. Our purpose was to analyze the potential dose reduction by decreasing the scan length of a neck CT and to assess for any clinically relevant information that might be missed from this modified approach. This retrospective study included 126 children who underwent a neck CT between August 1, 2013, and September 30, 2014. Alteration of the scan length for the modified CT was suggested on the topographic image on the basis of the indication of the study, with the reader blinded to the images and the report. The CT dose index volume of the original scan was multiplied by the new scan length to calculate the dose-length product of the modified study. The effective dose was calculated for the original and modified studies by using age-based conversion factors from the American Association of Physicists in Medicine Report No. 96. Decreasing the scan length resulted in an average estimated dose reduction of 47%. The average reduction in scan length was 10.4 cm, decreasing the overall coverage by 48%. The change in scan length did not result in any missed findings that altered management. Of the 27 abscesses in this study, none extended to the mediastinum. All of the lesions in question were completely covered. Decreasing the scan length of a neck CT according to the indication provides a significant savings in radiation dose, while not altering diagnostic ability or management. © 2016 by American Journal of Neuroradiology.

  1. A method for deriving a 4D-interpolated balanced planning target for mobile tumor radiotherapy.

    PubMed

    Roland, Teboh; Hales, Russell; McNutt, Todd; Wong, John; Simari, Patricio; Tryggestad, Erik

    2012-01-01

    Tumor control and normal tissue toxicity are strongly correlated to the tumor and normal tissue volumes receiving high prescribed dose levels in the course of radiotherapy. Planning target definition is, therefore, crucial to ensure favorable clinical outcomes. This is especially important for stereotactic body radiation therapy of lung cancers, characterized by high fractional doses and steep dose gradients. The shift in recent years from population-based to patient-specific treatment margins, as facilitated by the emergence of 4D medical imaging capabilities, is a major improvement. The commonly used motion-encompassing, or internal-target volume (ITV), target definition approach provides a high likelihood of coverage for the mobile tumor but inevitably exposes healthy tissue to high prescribed dose levels. The goal of this work was to generate an interpolated balanced planning target that takes into account both tumor coverage and normal tissue sparing from high prescribed dose levels, thereby improving on the ITV approach. For each 4DCT dataset, 4D deformable image registration was used to derive two bounding targets, namely, a 4D-intersection and a 4D-composite target which minimized normal tissue exposure to high prescribed dose levels and maximized tumor coverage, respectively. Through definition of an "effective overlap volume histogram" the authors derived an "interpolated balanced planning target" intended to balance normal tissue sparing from prescribed doses with tumor coverage. To demonstrate the dosimetric efficacy of the interpolated balanced planning target, the authors performed 4D treatment planning based on deformable image registration of 4D-CT data for five previously treated lung cancer patients. Two 4D plans were generated per patient, one based on the interpolated balanced planning target and the other based on the conventional ITV target. Plans were compared for tumor coverage and the degree of normal tissue sparing resulting from the new

  2. Improving target coverage and organ-at-risk sparing in intensity-modulated radiotherapy for cervical oesophageal cancer using a simple optimisation method.

    PubMed

    Lu, Jia-Yang; Cheung, Michael Lok-Man; Huang, Bao-Tian; Wu, Li-Li; Xie, Wen-Jia; Chen, Zhi-Jian; Li, De-Rui; Xie, Liang-Xi

    2015-01-01

    To assess the performance of a simple optimisation method for improving target coverage and organ-at-risk (OAR) sparing in intensity-modulated radiotherapy (IMRT) for cervical oesophageal cancer. For 20 selected patients, clinically acceptable original IMRT plans (Original plans) were created, and two optimisation methods were adopted to improve the plans: 1) a base dose function (BDF)-based method, in which the treatment plans were re-optimised based on the original plans, and 2) a dose-controlling structure (DCS)-based method, in which the original plans were re-optimised by assigning additional constraints for hot and cold spots. The Original, BDF-based and DCS-based plans were compared with regard to target dose homogeneity, conformity, OAR sparing, planning time and monitor units (MUs). Dosimetric verifications were performed and delivery times were recorded for the BDF-based and DCS-based plans. The BDF-based plans provided significantly superior dose homogeneity and conformity compared with both the DCS-based and Original plans. The BDF-based method further reduced the doses delivered to the OARs by approximately 1-3%. The re-optimisation time was reduced by approximately 28%, but the MUs and delivery time were slightly increased. All verification tests were passed and no significant differences were found. The BDF-based method for the optimisation of IMRT for cervical oesophageal cancer can achieve significantly better dose distributions with better planning efficiency at the expense of slightly more MUs.

  3. Change-Based Satellite Monitoring Using Broad Coverage and Targetable Sensing

    NASA Technical Reports Server (NTRS)

    Chien, Steve A.; Tran, Daniel Q.; Doubleday, Joshua R.; Doggett, Thomas

    2013-01-01

    A generic software framework analyzes data from broad coverage sweeps or general larger areas of interest. Change detection methods are used to extract subsets of directed swath areas that intersect areas of change. These areas are prioritized and allocated to targetable assets. This method is deployed in an automatic fashion, and has operated without human monitoring or intervention for sustained periods of time (months).

  4. SU-E-T-513: Investigating Dose of Internal Target Volume After Correcting for Tissue Heterogeneity in SBRT Lung Plans with Homogeneity Calculation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qi, P; Zhuang, T; Magnelli, A

    2015-06-15

    Purpose It was recommended to use the prescription of 54 Gy/3 with heterogeneity corrections for previously established dose scheme of 60 Gy/3 with homogeneity calculation. This study is to investigate dose coverage for the internal target volume (ITV) with and without heterogeneity correction. Methods Thirty patients who received stereotactic body radiotherapy (SBRT) to a dose of 60 Gy in 3 fractions with homogeneous planning for early stage non-small-cell lung cancer (NSCLC) were selected. ITV was created either from 4DCT scans or a fusion of multi-phase respiratory scans. Planning target volume (PTV) was a 5 mm expansion of the ITV. Formore » this study, we recalculated homogeneous clinical plans using heterogeneity corrections with monitor units set as clinically delivered. All plans were calculated with 3 mm dose grids and collapsed cone convolution algorithm. To account for uncertainties from tumor delineation and image-guided radiotherapy, a structure ITV2mm was created by expanding ITV with 2 mm margins. Dose coverage to the PTV, ITV and ITV2mm were compared with a student paired t-test. Results With heterogeneity corrections, the PTV V60Gy decreased by 10.1% ± 18.4% (p<0.01) while the maximum dose to the PTV increased by 3.7 ± 4.3% (p<0.01). With and without corrections, D99% was 65.8 ± 4.0 Gy and 66.7 ± 4.8 Gy (p=0.15) for the ITV, and 63.9 ± 3.4 Gy and 62.9 ± 4.6 Gy for the ITV2mm (p=0.22), respectively. The mean dose to the ITV and ITV2mm increased 3.6% ± 4.7% (p<0.01) and 2.3% ± 5.2% (p=0.01) with heterogeneity corrections. Conclusion After heterogeneity correction, the peripheral coverage of the PTV decreased to approximately 54 Gy, but D99% of the ITV and ITV2mm was unchanged and the mean dose to the ITV and ITV2mm was increased. Clinical implication of these results requires more investigation.« less

  5. Targeting MRS-Defined Dominant Intraprostatic Lesions with Inverse-Planned High Dose Rate Brachytherapy

    DTIC Science & Technology

    2007-02-01

    bladder and the rectum are overprotected while the PTV coverage is undesirably reduced. On the other hand, if their maximum dose is increased and/or...B, the bladder and rectum were overprotected with undesirably low PTV coverage (84.54%). The reduction of their weighting factor increased PTV

  6. Measles transmission following the tsunami in a population with a high one-dose vaccination coverage, Tamil Nadu, India 2004–2005

    PubMed Central

    Mohan, Arumugam; Murhekar, Manoj V; Wairgkar, Niteen S; Hutin, Yvan J; Gupte, Mohan D

    2006-01-01

    Background On 26 December 2004, a tsunami struck the coast of the state of Tamil Nadu, India, where one-dose measles coverage exceeded 95%. On 29 December, supplemental measles immunization activities targeted children 6 to 60 months of age in affected villages. On 30 December, Cuddalore, a tsunami-affected district in Tamil Nadu reported a cluster of measles cases. We investigated this cluster to estimate the magnitude of the problem and to propose recommendations for control. Methods We received notification of WHO-defined measles cases through stimulated passive surveillance. We collected information regarding date of onset, age, sex, vaccination status and residence. We collected samples for IgM antibodies and genotype studies. We modeled the accumulation of susceptible individuals over the time on the basis of vaccination coverage, vaccine efficacy and birth rate. Results We identified 101 measles cases and detected IgM antibodies against measles virus in eight of 11 sera. Cases were reported from tsunami-affected (n = 71) and unaffected villages (n = 30) with attack rates of 1.3 and 1.7 per 1000, respectively. 42% of cases in tsunami-affected villages had an onset date within 14 days of the tsunami. The median ages of case-patients in tsunami-affected and un-affected areas were 54 months and 60 months respectively (p = 0.471). 36% of cases from tsunami-affected areas were above 60 months of age. Phylogenetic analyses indicated that the sequences of virus belonged to genotype D8 that circulated in Tamil Nadu. Conclusion Measles virus circulated in Cuddalore district following the tsunami, although there was no association between the two events. Transmission despite high one-dose vaccination coverage pointed to the limitations of this vaccination strategy. A second opportunity for measles immunization may help reducing measles mortality and morbidity in such areas. Children from 6 month to 14 years of age must be targeted for supplemental immunization during

  7. Influenza vaccination coverage among US children from 2004/2005 to 2015/2016.

    PubMed

    Tian, Changwei; Wang, Hua; Wang, Wenming; Luo, Xiaoming

    2018-05-15

    Quantify the influenza vaccine coverage is essential to identify emerging concerns and to immunization programs for targeting interventions. Data from National Health Interview Survey were used to estimate receipt of at least one dose of influenza vaccination among children 6 months to 17 years of age. Influenza vaccination coverage increased from 16.70% during 2004/2005 to 49.43% during 2015/2016 (3.18% per year, P < 0.001); however, the coverage increased slightly after 2010/2011. Children at high risk of influenza complications had higher influenza vaccination coverage than non at-risk children. Boys and girls had similar coverage each year. While the coverage increased from 2004/2005 to 2015/2016 for all age groups, the coverage decreased with age each year (-0.64 to -1.58% per age group). There was a higher and rapid increase of coverage in Northeast than Midwest, South and West. American Indian or Alaskan Native and Asian showed higher coverage than other race groups (White, Black/African American, Multiple race). Multivariable analysis showed that high-risk status and region had the greatest associations with levels of vaccine coverage. Although the influenza vaccination coverage among children had increased remarkably since 2004/2005, establishing more effective immunization programs are warranted to achieve the Healthy People 2020 target.

  8. Applications of tissue heterogeneity corrections and biologically effective dose volume histograms in assessing the doses for accelerated partial breast irradiation using an electronic brachytherapy source.

    PubMed

    Shi, Chengyu; Guo, Bingqi; Cheng, Chih-Yao; Eng, Tony; Papanikolaou, Nikos

    2010-09-21

    A low-energy electronic brachytherapy source (EBS), the model S700 Axxent x-ray device developed by Xoft Inc., has been used in high dose rate (HDR) intracavitary accelerated partial breast irradiation (APBI) as an alternative to an Ir-192 source. The prescription dose and delivery schema of the electronic brachytherapy APBI plan are the same as the Ir-192 plan. However, due to its lower mean energy than the Ir-192 source, an EBS plan has dosimetric and biological features different from an Ir-192 source plan. Current brachytherapy treatment planning methods may have large errors in treatment outcome prediction for an EBS plan. Two main factors contribute to the errors: the dosimetric influence of tissue heterogeneities and the enhancement of relative biological effectiveness (RBE) of electronic brachytherapy. This study quantified the effects of these two factors and revisited the plan quality of electronic brachytherapy APBI. The influence of tissue heterogeneities is studied by a Monte Carlo method and heterogeneous 'virtual patient' phantoms created from CT images and structure contours; the effect of RBE enhancement in the treatment outcome was estimated by biologically effective dose (BED) distribution. Ten electronic brachytherapy APBI cases were studied. The results showed that, for electronic brachytherapy cases, tissue heterogeneities and patient boundary effect decreased dose to the target and skin but increased dose to the bones. On average, the target dose coverage PTV V(100) reduced from 95.0% in water phantoms (planned) to only 66.7% in virtual patient phantoms (actual). The actual maximum dose to the ribs is 3.3 times higher than the planned dose; the actual mean dose to the ipsilateral breast and maximum dose to the skin were reduced by 22% and 17%, respectively. Combining the effect of tissue heterogeneities and RBE enhancement, BED coverage of the target was 89.9% in virtual patient phantoms with RBE enhancement (actual BED) as compared to 95

  9. Applications of tissue heterogeneity corrections and biologically effective dose volume histograms in assessing the doses for accelerated partial breast irradiation using an electronic brachytherapy source

    NASA Astrophysics Data System (ADS)

    Shi, Chengyu; Guo, Bingqi; Cheng, Chih-Yao; Eng, Tony; Papanikolaou, Nikos

    2010-09-01

    A low-energy electronic brachytherapy source (EBS), the model S700 Axxent™ x-ray device developed by Xoft Inc., has been used in high dose rate (HDR) intracavitary accelerated partial breast irradiation (APBI) as an alternative to an Ir-192 source. The prescription dose and delivery schema of the electronic brachytherapy APBI plan are the same as the Ir-192 plan. However, due to its lower mean energy than the Ir-192 source, an EBS plan has dosimetric and biological features different from an Ir-192 source plan. Current brachytherapy treatment planning methods may have large errors in treatment outcome prediction for an EBS plan. Two main factors contribute to the errors: the dosimetric influence of tissue heterogeneities and the enhancement of relative biological effectiveness (RBE) of electronic brachytherapy. This study quantified the effects of these two factors and revisited the plan quality of electronic brachytherapy APBI. The influence of tissue heterogeneities is studied by a Monte Carlo method and heterogeneous 'virtual patient' phantoms created from CT images and structure contours; the effect of RBE enhancement in the treatment outcome was estimated by biologically effective dose (BED) distribution. Ten electronic brachytherapy APBI cases were studied. The results showed that, for electronic brachytherapy cases, tissue heterogeneities and patient boundary effect decreased dose to the target and skin but increased dose to the bones. On average, the target dose coverage PTV V100 reduced from 95.0% in water phantoms (planned) to only 66.7% in virtual patient phantoms (actual). The actual maximum dose to the ribs is 3.3 times higher than the planned dose; the actual mean dose to the ipsilateral breast and maximum dose to the skin were reduced by 22% and 17%, respectively. Combining the effect of tissue heterogeneities and RBE enhancement, BED coverage of the target was 89.9% in virtual patient phantoms with RBE enhancement (actual BED) as compared to 95

  10. An Evaluation of Voluntary Varicella Vaccination Coverage in Zhejiang Province, East China.

    PubMed

    Hu, Yu; Chen, Yaping; Zhang, Bing; Li, Qian

    2016-06-03

    In 2014 a 2-doses varicella vaccine (VarV) schedule was recommended by the Zhejiang Provincial Center for Disease Control and Prevention. We aimed to assess the coverage of the 1st dose of VarV (VarV₁) and the 2nd dose of VarV (VarV₂) among children aged 2-6 years through the Zhejiang Provincial Immunization Information System (ZJIIS) and to explore the determinants associated with the VarV coverage. Children aged 2-6 years (born from 1 January 2009 to 31 December 2013) registered in ZJIIS were enrolled. Anonymized individual records of target children were extracted from the ZJIIS database on 1 January 2016, including their VarV and (measles-containing vaccine) MCV vaccination information. The VarV₁ and VarV₂ coverage rates were evaluated for each birth cohorts. The coverage of VarV also was estimated among strata defined by cities, gender and immigration status. We also evaluated the difference in coverage between VarV and MCV. A total of 3,028,222 children aged 2-6 years were enrolled. The coverage of VarV₁ ranged from 84.8% to 87.9% in the 2009-2013 birth cohorts, while the coverage of VarV₂ increased from 31.8% for the 2009 birth cohort to 48.7% for the 2011 birth cohort. Higher coverage rates for both VarV₁ and VarV₂ were observed among resident children in relevant birth cohorts. The coverage rates of VarV₁ and VarV₂ were lower than those for the 1st and 2nd dose of MCV, which were above 95%. The proportion of children who were vaccinated with VarV₁ at the recommended age increased from 34.6% for the 2009 birth cohort to 75.2% for the 2013 birth cohort, while the proportion of children who were vaccinated with VarV₂ at the recommended age increased from 19.7% for the 2009 birth cohort to 48.7% for the 2011 birth cohort. Our study showed a rapid increasing VarV₂ coverage of children, indicating a growing acceptance of the 2-doses VarV schedule among children's caregivers and physicians after the new recommendation released. We

  11. Improvements in dose calculation accuracy for small off-axis targets in high dose per fraction tomotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardcastle, Nicholas; Bayliss, Adam; Wong, Jeannie Hsiu Ding

    2012-08-15

    Purpose: A recent field safety notice from TomoTherapy detailed the underdosing of small, off-axis targets when receiving high doses per fraction. This is due to angular undersampling in the dose calculation gantry angles. This study evaluates a correction method to reduce the underdosing, to be implemented in the current version (v4.1) of the TomoTherapy treatment planning software. Methods: The correction method, termed 'Super Sampling' involved the tripling of the number of gantry angles from which the dose is calculated during optimization and dose calculation. Radiochromic film was used to measure the dose to small targets at various off-axis distances receivingmore » a minimum of 21 Gy in one fraction. Measurements were also performed for single small targets at the center of the Lucy phantom, using radiochromic film and the dose magnifying glass (DMG). Results: Without super sampling, the peak dose deficit increased from 0% to 18% for a 10 mm target and 0% to 30% for a 5 mm target as off-axis target distances increased from 0 to 16.5 cm. When super sampling was turned on, the dose deficit trend was removed and all peak doses were within 5% of the planned dose. For measurements in the Lucy phantom at 9.7 cm off-axis, the positional and dose magnitude accuracy using super sampling was verified using radiochromic film and the DMG. Conclusions: A correction method implemented in the TomoTherapy treatment planning system which triples the angular sampling of the gantry angles used during optimization and dose calculation removes the underdosing for targets as small as 5 mm diameter, up to 16.5 cm off-axis receiving up to 21 Gy.« less

  12. Dose gradient curve: A new tool for evaluating dose gradient.

    PubMed

    Sung, KiHoon; Choi, Young Eun

    2018-01-01

    Stereotactic radiotherapy, which delivers an ablative high radiation dose to a target volume for maximum local tumor control, requires a rapid dose fall-off outside the target volume to prevent extensive damage to nearby normal tissue. Currently, there is no tool to comprehensively evaluate the dose gradient near the target volume. We propose the dose gradient curve (DGC) as a new tool to evaluate the quality of a treatment plan with respect to the dose fall-off characteristics. The average distance between two isodose surfaces was represented by the dose gradient index (DGI) estimated by a simple equation using the volume and surface area of isodose levels. The surface area was calculated by mesh generation and surface triangulation. The DGC was defined as a plot of the DGI of each dose interval as a function of the dose. Two types of DGCs, differential and cumulative, were generated. The performance of the DGC was evaluated using stereotactic radiosurgery plans for virtual targets. Over the range of dose distributions, the dose gradient of each dose interval was well-characterized by the DGC in an easily understandable graph format. Significant changes in the DGC were observed reflecting the differences in planning situations and various prescription doses. The DGC is a rational method for visualizing the dose gradient as the average distance between two isodose surfaces; the shorter the distance, the steeper the dose gradient. By combining the DGC with the dose-volume histogram (DVH) in a single plot, the DGC can be utilized to evaluate not only the dose gradient but also the target coverage in routine clinical practice.

  13. Dose gradient curve: A new tool for evaluating dose gradient

    PubMed Central

    Choi, Young Eun

    2018-01-01

    Purpose Stereotactic radiotherapy, which delivers an ablative high radiation dose to a target volume for maximum local tumor control, requires a rapid dose fall-off outside the target volume to prevent extensive damage to nearby normal tissue. Currently, there is no tool to comprehensively evaluate the dose gradient near the target volume. We propose the dose gradient curve (DGC) as a new tool to evaluate the quality of a treatment plan with respect to the dose fall-off characteristics. Methods The average distance between two isodose surfaces was represented by the dose gradient index (DGI) estimated by a simple equation using the volume and surface area of isodose levels. The surface area was calculated by mesh generation and surface triangulation. The DGC was defined as a plot of the DGI of each dose interval as a function of the dose. Two types of DGCs, differential and cumulative, were generated. The performance of the DGC was evaluated using stereotactic radiosurgery plans for virtual targets. Results Over the range of dose distributions, the dose gradient of each dose interval was well-characterized by the DGC in an easily understandable graph format. Significant changes in the DGC were observed reflecting the differences in planning situations and various prescription doses. Conclusions The DGC is a rational method for visualizing the dose gradient as the average distance between two isodose surfaces; the shorter the distance, the steeper the dose gradient. By combining the DGC with the dose-volume histogram (DVH) in a single plot, the DGC can be utilized to evaluate not only the dose gradient but also the target coverage in routine clinical practice. PMID:29698471

  14. Vaccination coverage according to doses received and timely administered based on an electronic immunization registry, Araraquara-SP, Brazil, 2012-2014.

    PubMed

    Tauil, Márcia de Cantuária; Sato, Ana Paula Sayuri; Costa, Ângela Aparecida; Inenami, Marta; Ferreira, Vinícius Leati de Rossi; Waldman, Eliseu Alves

    2017-01-01

    to describe vaccine coverage by type of vaccine at 12 and 24 months of age. descriptive cohort study with children born in 2012, living in Araraquara-SP, Brazil, recorded in the Information System on Live Births (Sinasc); a manual linkage of Sinasc data with an electronic immunization registry (EIR) was performed; the assessment was based on vaccination status according to São Paulo State recommendations, and on doses received and timely administered. 2,740 children were registered on Sinasc and 99.6% of them were included into EIR; among the 2,612 (95.3%) children studied, the triple viral vaccine (measles, mumps and rubella) had the lowest coverage at 12 months for received dose (74.8%) and at 24 months for timely vaccination (53.5%) and received doses (88.0%). coverage was higher than 90% for most vaccines; however, delayed vaccination was observed, which indicates the need to intensify actions aimed at timely vaccination.

  15. Dosimetric comparison between VMAT with different dose calculation algorithms and protons for soft-tissue sarcoma radiotherapy.

    PubMed

    Fogliata, Antonella; Scorsetti, Marta; Navarria, Piera; Catalano, Maddalena; Clivio, Alessandro; Cozzi, Luca; Lobefalo, Francesca; Nicolini, Giorgia; Palumbo, Valentina; Pellegrini, Chiara; Reggiori, Giacomo; Roggio, Antonella; Vanetti, Eugenio; Alongi, Filippo; Pentimalli, Sara; Mancosu, Pietro

    2013-04-01

    To appraise the potential of volumetric modulated arc therapy (VMAT, RapidArc) and proton beams to simultaneously achieve target coverage and enhanced sparing of bone tissue in the treatment of soft-tissue sarcoma with adequate target coverage. Ten patients presenting with soft-tissue sarcoma of the leg were collected for the study. Dose was prescribed to 66.5 Gy in 25 fractions to the planning target volume (PTV) while significant maximum dose to the bone was constrained to 50 Gy. Plans were optimised according to the RapidArc technique with 6 MV photon beams or for intensity modulated protons. RapidArc photon plans were computed with: 1) AAA; 2) Acuros XB as dose to medium; and 3) Acuros XB as dose to water. All plans acceptably met the criteria of target coverage (V95% >90-95%) and bone sparing (D(1 cm3) <50 Gy). Significantly higher PTV dose homogeneity was found for proton plans. Near-to-maximum dose to bone was similar for RapidArc and protons, while volume receiving medium/low dose levels was minimised with protons. Similar results were obtained for the remaining normal tissue. Dose distributions calculated with the dose to water option resulted ~5% higher than corresponding ones computed as dose to medium. High plan quality was demonstrated for both VMAT and proton techniques when applied to soft-tissue sarcoma.

  16. SU-E-T-486: Effect of the Normalized Prescription Isodose Line On Target Dose Deficiency in Lung SBRT Based On Monte Carlo Calculation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, D; Zhang, Q; Zhou, S

    Purpose: To investigate the impact of normalized prescription isodose line on target dose deficiency calculated with Monte Carlo (MC) vs. pencil Beam (PB) in lung SBRT. RTOG guidelines recommend prescription lines between 60% and 90% for lung SBRT. How this affects the magnitude of MC-calculated target dose deficiency has never been studied. Methods: Under an IRB-approved protocol, four lung SBRT patients were replanned following RTOG0813 by a single physicist. For each patient, four alternative plans were generated based on PB calculation prescribing to 60–90% isodose lines, respectively. Each plan consisted of 360o coplanar dynamic conformal arcs with beam apertures manuallymore » optimized to achieve similar dose coverage and conformity for all plans of the same patient. Dose distribution was calculated with MC and compared to that with PB. PTV dose-volume endpoints were compared, including Dmin, D5, Dmean, D95, and Dmax. PTV V100 coverage, conformity index (CI), and heterogeneity index (HI) were also evaluated. Results: For all 16 plans, median (range) PTV V100 and CI were 99.7% (97.5–100%) and 1.27 (1.20–1.41), respectively. As expected, lower prescription line resulted in higher target dose heterogeneity, yielding median (range) HI of 1.26 (1.05–1.51) for all plans. Comparing MC to PB, median (range) D95, Dmean, D5 PTV dose deficiency were 18.9% (11.2–23.2%), 15.6% (10.0–22.7%), and 9.4%(5.5–13.6%) of the prescription dose, respectively. The Dmean, D5, and Dmax deficiency was found to monotonically increase with decreasing prescription line from 90% to 60%, while the Dmin deficiency monotonically decreased. D95 deficiency exhibited more complex trend, reaching the largest deficiency at 80% for all patients. Conclusion: Dependence on prescription isodose line was found for MC-calculated PTV dose deficiency of lung SBRT. When comparing reported MC dose deficiency values from different institutions, their individual selections of prescription

  17. NSW annual immunisation coverage report, 2011.

    PubMed

    Hull, Brynley; Dey, Aditi; Campbell-Lloyd, Sue; Menzies, Robert I; McIntyre, Peter B

    2012-12-01

    This annual report, the third in the series, documents trends in immunisation coverage in NSW for children, adolescents and the elderly, to the end of 2011. Data from the Australian Childhood Immunisation Register, the NSW School Immunisation Program and the NSW Population Health Survey were used to calculate various measures of population coverage. During 2011, greater than 90% coverage was maintained for children at 12 and 24 months of age. For children at 5 years of age the improvement seen in 2010 was sustained, with coverage at or near 90%. For adolescents, there was improved coverage for all doses of human papillomavirus vaccine, both doses of hepatitis B vaccine, varicella vaccine and the dose of diphtheria, tetanus and acellular pertussis given to school attendees in Years 7 and 10. Pneumococcal vaccination coverage in the elderly has been steadily rising, although it has remained lower than the influenza coverage estimates. This report provides trends in immunisation coverage in NSW across the age spectrum. The inclusion of coverage estimates for the pneumococcal conjugate, varicella and meningococcal C vaccines in the official coverage assessments for 'fully immunised' in 2013 is a welcome initiative.

  18. Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume.

    PubMed

    Admiraal, Marjan A; Schuring, Danny; Hurkmans, Coen W

    2008-01-01

    The purpose of this study was to determine the 4D accumulated dose delivered to the CTV in stereotactic radiotherapy of lung tumours, for treatments planned on an average CT using an ITV derived from the Maximum Intensity Projection (MIP) CT. For 10 stage I lung cancer patients, treatment plans were generated based on 4D-CT images. From the 4D-CT scan, 10 time-sorted breathing phases were derived, along with the average CT and the MIP. The ITV with a margin of 0mm was used as a PTV to study a worst case scenario in which the differences between 3D planning and 4D dose accumulation will be largest. Dose calculations were performed on the average CT. Dose prescription was 60Gy to 95% of the PTV, and at least 54Gy should be received by 99% of the PTV. Plans were generated using the inverse planning module of the Pinnacle(3) treatment planning system. The plans consisted of nine coplanar beams with two segments each. After optimisation, the treatment plan was transferred to all breathing phases and the delivered dose per phase was calculated using an elastic body spline model available in our research version of Pinnacle (8.1r). Then, the cumulative dose to the CTV over all breathing phases was calculated and compared to the dose distribution of the original treatment plan. Although location, tumour size and breathing-induced tumour movement varied widely between patients, the PTV planning criteria could always be achieved without compromising organs at risk criteria. After 4D dose calculations, only very small differences between the initial planned PTV coverage and resulting CTV coverage were observed. For all patients, the dose delivered to 99% of the CTV exceeded 54Gy. For nine out of 10 patients also the criterion was met that the volume of the CTV receiving at least the prescribed dose was more than 95%. When the target dose is prescribed to the ITV (PTV=ITV) and dose calculations are performed on the average CT, the cumulative CTV dose compares well to the

  19. Reducing dose to the lungs through loosing target dose homogeneity requirement for radiotherapy of non small cell lung cancer.

    PubMed

    Miao, Junjie; Yan, Hui; Tian, Yuan; Ma, Pan; Liu, Zhiqiang; Li, Minghui; Ren, Wenting; Chen, Jiayun; Zhang, Ye; Dai, Jianrong

    2017-11-01

    It is important to minimize lung dose during intensity-modulated radiation therapy (IMRT) of nonsmall cell lung cancer (NSCLC). In this study, an approach was proposed to reduce lung dose by relaxing the constraint of target dose homogeneity during treatment planning of IMRT. Ten NSCLC patients with lung tumor on the right side were selected. The total dose for planning target volume (PTV) was 60 Gy (2 Gy/fraction). For each patient, two IMRT plans with six beams were created in Pinnacle treatment planning system. The dose homogeneity of target was controlled by constraints on the maximum and uniform doses of target volume. One IMRT plan was made with homogeneous target dose (the resulting target dose was within 95%-107% of the prescribed dose), while another IMRT plan was made with inhomogeneous target dose (the resulting target dose was more than 95% of the prescribed dose). During plan optimization, the dose of cord and heart in two types of IMRT plans were kept nearly the same. The doses of lungs, PTV and organs at risk (OARs) between two types of IMRT plans were compared and analyzed quantitatively. For all patients, the lung dose was decreased in the IMRT plans with inhomogeneous target dose. On average, the mean dose, V5, V20, and V30 of lung were reduced by 1.4 Gy, 4.8%, 3.7%, and 1.7%, respectively, and the dose to normal tissue was also reduced. These reductions in DVH values were all statistically significant (P < 0.05). There were no significant differences between the two IMRT plans on V25, V30, V40, V50 and mean dose for heart. The maximum doses of cords in two type IMRT plans were nearly the same. IMRT plans with inhomogeneous target dose could protect lungs better and may be considered as a choice for treating NSCLC. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  20. Feasibility and Initial Dosimetric Findings for a Randomized Trial Using Dose-Painted Multiparametric Magnetic Resonance Imaging–Defined Targets in Prostate Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bossart, Elizabeth L., E-mail: EBossart@med.miami.edu; Stoyanova, Radka; Sandler, Kiri

    2016-06-01

    Purpose: To compare dosimetric characteristics with multiparametric magnetic resonance imaging–identified imaging tumor volume (gross tumor volume, GTV), prostate clinical target volume and planning target volume, and organs at risk (OARs) for 2 treatment techniques representing 2 arms of an institutional phase 3 randomized trial of hypofractionated external beam image guided highly targeted radiation therapy. Methods and Materials: Group 1 (n=20) patients were treated before the trial inception with the standard dose prescription. Each patient had an additional treatment plan generated per the experimental arm. A total of 40 treatment plans were compared (20 plans for each technique). Group 2 (n=15)more » consists of patients currently accrued to the hypofractionated external beam image guided highly targeted radiation therapy trial. Plans were created as per the treatment arm, with additional plans for 5 of the group 2 experimental arm with a 3-mm expansion in the imaging GTV. Results: For all plans in both patient groups, planning target volume coverage ranged from 95% to 100%; GTV coverage of 89.3 Gy for the experimental treatment plans ranged from 95.2% to 99.8%. For both groups 1 and 2, the percent volumes of rectum/anus and bladder receiving 40 Gy, 65 Gy, and 80 Gy were smaller in the experimental plans than in the standard plans. The percent volume at 1 Gy per fraction and 1.625 Gy per fraction were compared between the standard and the experimental arms, and these were found to be equivalent. Conclusions: The dose per fraction to the OARs can be made equal even when giving a large simultaneous integrated boost to the GTV. The data suggest that a GTV margin may be added without significant dose effects on the OARs.« less

  1. Human Papillomavirus Vaccine Coverage and Prevalence of Missed Opportunities for Vaccination in an Integrated Healthcare System.

    PubMed

    Irving, Stephanie A; Groom, Holly C; Stokley, Shannon; McNeil, Michael M; Gee, Julianne; Smith, Ning; Naleway, Allison L

    2018-03-01

    Human papillomavirus (HPV) vaccination has been recommended in the United States for female and male adolescents since 2006 and 2011, respectively. Coverage rates are lower than those for other adolescent vaccines. The objective of this study was to evaluate an assessment and feedback intervention designed to increase HPV vaccination coverage and quantify missed opportunities for HPV vaccine initiation at preventive care visits. We examined changes in HPV vaccination coverage and missed opportunities within the adolescent (11-17 years) population at 9 Oregon-based Kaiser Permanente Northwest outpatient clinics after an assessment and feedback intervention. Quarterly coverage rates were calculated for the adolescent populations at the clinics, according to age group (11-12 and 13-17 years), sex, and department (Pediatrics and Family Medicine). Comparison coverage assessments were calculated at 3 nonintervention (control) clinics. Missed opportunities for HPV vaccine initiation, defined as preventive care visits in which a patient eligible for HPV dose 1 remained unvaccinated, were examined according to sex and age group. An average of 29,021 adolescents were included in coverage assessments. Before the intervention, 1-dose and 3-dose quarterly coverage rates were increasing at intervention as well as at control clinics in both age groups. Postimplementation quarterly trends in 1-dose or 3-dose coverage did not differ significantly between intervention and control clinics for either age group. One-dose coverage rates among adolescents with Pediatrics providers were significantly higher than those with Family Medicine providers (56% vs 41% for 11- to 12-year-old and 82% vs 69% for 13- to 17-year-old girls; 55% vs 40% for 11- to 12-year-old and 78% vs 62% for 13- to 17-year-old boys). No significant differences in HPV vaccine coverage were identified at intervention clinics. However, coverage rates were increasing before the start of the intervention and might have

  2. Comparative evaluation of two-dimensional radiography and three dimensional computed tomography based dose-volume parameters for high-dose-rate intracavitary brachytherapy of cervical cancer: a prospective study.

    PubMed

    Madan, Renu; Pathy, Sushmita; Subramani, Vellaiyan; Sharma, Seema; Mohanti, Bidhu Kalyan; Chander, Subhash; Thulkar, Sanjay; Kumar, Lalit; Dadhwal, Vatsla

    2014-01-01

    Dosimetric comparison of two dimensional (2D) radiography and three-dimensional computed tomography (3D-CT) based dose distributions with high-dose-rate (HDR) intracavitry radiotherapy (ICRT) for carcinoma cervix, in terms of target coverage and doses to bladder and rectum. Sixty four sessions of HDR ICRT were performed in 22 patients. External beam radiotherapy to pelvis at a dose of 50 Gray in 27 fractions followed by HDR ICRT, 21 Grays to point A in 3 sessions, one week apart was planned . All patients underwent 2D-orthogonal and 3D-CT simulation for each session. Treatment plans were generated using 2D-orthogonal images and dose prescription was made at point A. 3D plans were generated using 3D-CT images after delineating target volume and organs at risk. Comparative evaluation of 2D and 3D treatment planning was made for each session in terms of target coverage (dose received by 90%, 95% and 100% of the target volume: D90, D95 and D100 respectively) and doses to bladder and rectum: ICRU-38 bladder and rectum point dose in 2D planning and dose to 0.1cc, 1cc, 2cc, 5cc, and 10cc of bladder and rectum in 3D planning. Mean doses received by 100% and 90% of the target volume were 4.24 ± 0.63 and 4.9 ± 0.56 Gy respectively. Doses received by 0.1cc, 1cc and 2cc volume of bladder were 2.88 ± 0.72, 2.5 ± 0.65 and 2.2 ± 0.57 times more than the ICRU bladder reference point. Similarly, doses received by 0.1cc, 1cc and 2cc of rectum were 1.80 ± 0.5, 1.48 ± 0.41 and 1.35 ± 0.37 times higher than ICRU rectal reference point. Dosimetric comparative evaluation of 2D and 3D CT based treatment planning for the same brachytherapy session demonstrates underestimation of OAR doses and overestimation of target coverage in 2D treatment planning.

  3. Dose coverage calculation using a statistical shape model—applied to cervical cancer radiotherapy

    NASA Astrophysics Data System (ADS)

    Tilly, David; van de Schoot, Agustinus J. A. J.; Grusell, Erik; Bel, Arjan; Ahnesjö, Anders

    2017-05-01

    A comprehensive methodology for treatment simulation and evaluation of dose coverage probabilities is presented where a population based statistical shape model (SSM) provide samples of fraction specific patient geometry deformations. The learning data consists of vector fields from deformable image registration of repeated imaging giving intra-patient deformations which are mapped to an average patient serving as a common frame of reference. The SSM is created by extracting the most dominating eigenmodes through principal component analysis of the deformations from all patients. The sampling of a deformation is thus reduced to sampling weights for enough of the most dominating eigenmodes that describe the deformations. For the cervical cancer patient datasets in this work, we found seven eigenmodes to be sufficient to capture 90% of the variance in the deformations of the, and only three eigenmodes for stability in the simulated dose coverage probabilities. The normality assumption of the eigenmode weights was tested and found relevant for the 20 most dominating eigenmodes except for the first. Individualization of the SSM is demonstrated to be improved using two deformation samples from a new patient. The probabilistic evaluation provided additional information about the trade-offs compared to the conventional single dataset treatment planning.

  4. TU-AB-BRB-01: Coverage Evaluation and Probabilistic Treatment Planning as a Margin Alternative

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siebers, J.

    The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. Themore » treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To

  5. Increasing the Structural Coverage of Tuberculosis Drug Targets

    PubMed Central

    Baugh, Loren; Phan, Isabelle; Begley, Darren W.; Clifton, Matthew C.; Armour, Brianna; Dranow, David M.; Taylor, Brandy M.; Muruthi, Marvin M.; Abendroth, Jan; Fairman, James W.; Fox, David; Dieterich, Shellie H.; Staker, Bart L.; Gardberg, Anna S.; Choi, Ryan; Hewitt, Stephen N.; Napuli, Alberto J.; Myers, Janette; Barrett, Lynn K.; Zhang, Yang; Ferrell, Micah; Mundt, Elizabeth; Thompkins, Katie; Tran, Ngoc; Lyons-Abbott, Sally; Abramov, Ariel; Sekar, Aarthi; Serbzhinskiy, Dmitri; Lorimer, Don; Buchko, Garry W.; Stacy, Robin; Stewart, Lance J.; Edwards, Thomas E.; Van Voorhis, Wesley C.; Myler, Peter J.

    2015-01-01

    High-resolution three-dimensional structures of essential Mycobacterium tuberculosis (Mtb) proteins provide templates for TB drug design, but are available for only a small fraction of the Mtb proteome. Here we evaluate an intra-genus “homolog-rescue” strategy to increase the structural information available for TB drug discovery by using mycobacterial homologs with conserved active sites. Of 179 potential TB drug targets selected for x-ray structure determination, only 16 yielded a crystal structure. By adding 1675 homologs from nine other mycobacterial species to the pipeline, structures representing an additional 52 otherwise intractable targets were solved. To determine whether these homolog structures would be useful surrogates in TB drug design, we compared the active sites of 106 pairs of Mtb and non-TB mycobacterial (NTM) enzyme homologs with experimentally determined structures, using three metrics of active site similarity, including superposition of continuous pharmacophoric property distributions. Pair-wise structural comparisons revealed that 19/22 pairs with >55% overall sequence identity had active site Cα RMSD <1Å, >85% side chain identity, and ≥80% PSAPF (similarity based on pharmacophoric properties) indicating highly conserved active site shape and chemistry. Applying these results to the 52 NTM structures described above, 41 shared >55% sequence identity with the Mtb target, thus increasing the effective structural coverage of the 179 Mtb targets over three-fold (from 9% to 32%). The utility of these structures in TB drug design can be tested by designing inhibitors using the homolog structure and assaying the cognate Mtb enzyme; a promising test case, Mtb cytidylate kinase, is described. The homolog-rescue strategy evaluated here for TB is also generalizable to drug targets for other diseases. PMID:25613812

  6. Philippine protected areas are not meeting the biodiversity coverage and management effectiveness requirements of Aichi Target 11.

    PubMed

    Mallari, Neil Aldrin D; Collar, Nigel J; McGowan, Philip J K; Marsden, Stuart J

    2016-04-01

    Aichi Target 11 of the Convention on Biological Diversity urges, inter alia, that nations protect at least 17 % of their land, and that protection is effective and targets areas of importance for biodiversity. Five years before reporting on Aichi targets is due, we assessed the Philippines' current protected area system for biodiversity coverage, appropriateness of management regimes and capacity to deliver protection. Although protected estate already covers 11 % of the Philippines' land area, 64 % of its key biodiversity areas (KBAs) remain unprotected. Few protected areas have appropriate management and governance infrastructures, funding streams, management plans and capacity, and a serious mismatch exists between protected area land zonation regimes and conservation needs of key species. For the Philippines to meet the biodiversity coverage and management effectiveness elements of Aichi Target 11, protected area and KBA boundaries should be aligned, management systems reformed to pursue biodiversity-led targets and effective management capacity created.

  7. A Target Coverage Scheduling Scheme Based on Genetic Algorithms in Directional Sensor Networks

    PubMed Central

    Gil, Joon-Min; Han, Youn-Hee

    2011-01-01

    As a promising tool for monitoring the physical world, directional sensor networks (DSNs) consisting of a large number of directional sensors are attracting increasing attention. As directional sensors in DSNs have limited battery power and restricted angles of sensing range, maximizing the network lifetime while monitoring all the targets in a given area remains a challenge. A major technique to conserve the energy of directional sensors is to use a node wake-up scheduling protocol by which some sensors remain active to provide sensing services, while the others are inactive to conserve their energy. In this paper, we first address a Maximum Set Covers for DSNs (MSCD) problem, which is known to be NP-complete, and present a greedy algorithm-based target coverage scheduling scheme that can solve this problem by heuristics. This scheme is used as a baseline for comparison. We then propose a target coverage scheduling scheme based on a genetic algorithm that can find the optimal cover sets to extend the network lifetime while monitoring all targets by the evolutionary global search technique. To verify and evaluate these schemes, we conducted simulations and showed that the schemes can contribute to extending the network lifetime. Simulation results indicated that the genetic algorithm-based scheduling scheme had better performance than the greedy algorithm-based scheme in terms of maximizing network lifetime. PMID:22319387

  8. Immunisation coverage, 2012.

    PubMed

    Hull, Brynley P; Dey, Aditi; Menzies, Rob I; Brotherton, Julia M; McIntyre, Peter B

    2014-09-30

    suboptimal coverage at 60.1% and 73.1%, respectively, although there was a considerable improvement in coverage from 2011, 57.7% and 68.2% respectively. On-time receipt (before 49 months of age) of vaccines by Indigenous children at the 60-month milestone age improved substantially between 2011 (19%) and 2012 (38%) but the disparity in on-time vaccination between Indigenous and non-Indigenous children worsened at the 60-month age milestone from 2011 (from 1.8 to 5.4 percentage points) and remained the same for the 12 and 24-month age milestones. By late 2012, the percentage of children who received the 1st dose of DTPa vaccine dose at less than 8 weeks of age was greater than 50% in all but 1 jurisdiction and greater than 70% for New South Wales, the Australian Capital Territory and Tasmania. Further, by late 2012, the percentage of children who received the 4th dose of DTPa vaccine dose at less than 4 years of age was greater than 30% in 3 jurisdictions. The percentage of children whose parents officially objected to vaccination in Australia was 1.7% and this figure varied by jurisdiction. However, there is a further 2.1% of children whose parents don't officially object but whose children have no vaccines recorded on the ACIR. Coverage data for the 3rd dose of HPV from the national HPV register in the school catch up program was similar to 2011 at 71% but was substantially lower for the catch up program for females outside school (44%-69%), although this was an improvement from 2011.

  9. SU-E-T-495: Influence of Reduced Target-To-Nozzle Distance On Secondary Neutron Dose Equivalent in Proton and Carbon Ion Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheng, Y; Shahnazi, K; Wang, W

    Purpose: Ion beams have an unavoidable lateral spread due to nuclear interactions interacting with the air and monitoring systems. To minimize this spread, the distance between the nozzle and the patient should be kept as small as possible.The purpose of this work was to determine the impact of the target-to-nozzle distance reduction on the secondary neutron dose equivalent in proton and carbon ion radiotherapy. Methods: In this study, abdominal and head phantoms were scanned with our CT scanner. Cubical targets with side lengths of 3 cm to 10 cm and 1 cm to 5 cm were drawn in the abdominalmore » and head phantoms respectively. Two intensity-modulated plans were made for each phantom and ion. The first of these plans placed the target at the isocenter while the other shifted the phantom 30 cm towards the nozzle. The plans at both phantom locations were optimized to provide identical dose coverage to the PTVs.Secondary neutron dose equivalent at 50 cm lateral to the center of target. Results: The neutron dose equivalent was higher for the larger field size from 0.25µSv per Gy (RBE) to 72µSv per Gy (RBE). The neutron dose equivalent was smaller when the phantom was placed at the upstream target location versus at the isocenter location by 8.9% to 10.4% and 11.0% to 22.1% for proton plans of the abdominal and head phantoms respectively. Differences for carbon plans with different target-to-nozzle locations were less than 3% for both phantoms. Conclusion: A reduction of target-to-nozzle distance can lead to benefits for proton radiotherapy. In this study, a reduction of secondary neutron dose equivalent was found for proton plans with a smaller target-to-nozzle distance. A greater impact was found for a head phantom with a smaller field size; however, a reduction of the target-to-nozzle distance had little effect for carbon therapy.« less

  10. Increasing the structural coverage of tuberculosis drug targets.

    PubMed

    Baugh, Loren; Phan, Isabelle; Begley, Darren W; Clifton, Matthew C; Armour, Brianna; Dranow, David M; Taylor, Brandy M; Muruthi, Marvin M; Abendroth, Jan; Fairman, James W; Fox, David; Dieterich, Shellie H; Staker, Bart L; Gardberg, Anna S; Choi, Ryan; Hewitt, Stephen N; Napuli, Alberto J; Myers, Janette; Barrett, Lynn K; Zhang, Yang; Ferrell, Micah; Mundt, Elizabeth; Thompkins, Katie; Tran, Ngoc; Lyons-Abbott, Sally; Abramov, Ariel; Sekar, Aarthi; Serbzhinskiy, Dmitri; Lorimer, Don; Buchko, Garry W; Stacy, Robin; Stewart, Lance J; Edwards, Thomas E; Van Voorhis, Wesley C; Myler, Peter J

    2015-03-01

    High-resolution three-dimensional structures of essential Mycobacterium tuberculosis (Mtb) proteins provide templates for TB drug design, but are available for only a small fraction of the Mtb proteome. Here we evaluate an intra-genus "homolog-rescue" strategy to increase the structural information available for TB drug discovery by using mycobacterial homologs with conserved active sites. Of 179 potential TB drug targets selected for x-ray structure determination, only 16 yielded a crystal structure. By adding 1675 homologs from nine other mycobacterial species to the pipeline, structures representing an additional 52 otherwise intractable targets were solved. To determine whether these homolog structures would be useful surrogates in TB drug design, we compared the active sites of 106 pairs of Mtb and non-TB mycobacterial (NTM) enzyme homologs with experimentally determined structures, using three metrics of active site similarity, including superposition of continuous pharmacophoric property distributions. Pair-wise structural comparisons revealed that 19/22 pairs with >55% overall sequence identity had active site Cα RMSD <1 Å, >85% side chain identity, and ≥80% PSAPF (similarity based on pharmacophoric properties) indicating highly conserved active site shape and chemistry. Applying these results to the 52 NTM structures described above, 41 shared >55% sequence identity with the Mtb target, thus increasing the effective structural coverage of the 179 Mtb targets over three-fold (from 9% to 32%). The utility of these structures in TB drug design can be tested by designing inhibitors using the homolog structure and assaying the cognate Mtb enzyme; a promising test case, Mtb cytidylate kinase, is described. The homolog-rescue strategy evaluated here for TB is also generalizable to drug targets for other diseases. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Increasing the structural coverage of tuberculosis drug targets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baugh, Loren; Phan, Isabelle; Begley, Darren W.

    High-resolution three-dimensional structures of essential Mycobacterium tuberculosis (Mtb) proteins provide templates for TB drug design, but are available for only a small fraction of the Mtb proteome. Here we evaluate an intra-genus “homolog-rescue” strategy to increase the structural information available for TB drug discovery by using mycobacterial homologs with conserved active sites. We found that of 179 potential TB drug targets selected for x-ray structure determination, only 16 yielded a crystal structure. By adding 1675 homologs from nine other mycobacterial species to the pipeline, structures representing an additional 52 otherwise intractable targets were solved. To determine whether these homolog structuresmore » would be useful surrogates in TB drug design, we compared the active sites of 106 pairs of Mtb and non-TB mycobacterial (NTM) enzyme homologs with experimentally determined structures, using three metrics of active site similarity, including superposition of continuous pharmacophoric property distributions. Pair-wise structural comparisons revealed that 19/22 pairs with >55% overall sequence identity had active site Cα RMSD <1 Å, >85% side chain identity, and ≥80% PS APF (similarity based on pharmacophoric properties) indicating highly conserved active site shape and chemistry. Applying these results to the 52 NTM structures described above, 41 shared >55% sequence identity with the Mtb target, thus increasing the effective structural coverage of the 179 Mtb targets over three-fold (from 9% to 32%). The utility of these structures in TB drug design can be tested by designing inhibitors using the homolog structure and assaying the cognate Mtb enzyme; a promising test case, Mtb cytidylate kinase, is described. The homolog-rescue strategy evaluated here for TB is also generalizable to drug targets for other diseases.« less

  12. Increasing the structural coverage of tuberculosis drug targets

    DOE PAGES

    Baugh, Loren; Phan, Isabelle; Begley, Darren W.; ...

    2014-12-19

    High-resolution three-dimensional structures of essential Mycobacterium tuberculosis (Mtb) proteins provide templates for TB drug design, but are available for only a small fraction of the Mtb proteome. Here we evaluate an intra-genus “homolog-rescue” strategy to increase the structural information available for TB drug discovery by using mycobacterial homologs with conserved active sites. We found that of 179 potential TB drug targets selected for x-ray structure determination, only 16 yielded a crystal structure. By adding 1675 homologs from nine other mycobacterial species to the pipeline, structures representing an additional 52 otherwise intractable targets were solved. To determine whether these homolog structuresmore » would be useful surrogates in TB drug design, we compared the active sites of 106 pairs of Mtb and non-TB mycobacterial (NTM) enzyme homologs with experimentally determined structures, using three metrics of active site similarity, including superposition of continuous pharmacophoric property distributions. Pair-wise structural comparisons revealed that 19/22 pairs with >55% overall sequence identity had active site Cα RMSD <1 Å, >85% side chain identity, and ≥80% PS APF (similarity based on pharmacophoric properties) indicating highly conserved active site shape and chemistry. Applying these results to the 52 NTM structures described above, 41 shared >55% sequence identity with the Mtb target, thus increasing the effective structural coverage of the 179 Mtb targets over three-fold (from 9% to 32%). The utility of these structures in TB drug design can be tested by designing inhibitors using the homolog structure and assaying the cognate Mtb enzyme; a promising test case, Mtb cytidylate kinase, is described. The homolog-rescue strategy evaluated here for TB is also generalizable to drug targets for other diseases.« less

  13. Consequences of additional use of PET information for target volume delineation and radiotherapy dose distribution for esophageal cancer.

    PubMed

    Muijs, Christina T; Schreurs, Liesbeth M; Busz, Dianne M; Beukema, Jannet C; van der Borden, Arnout J; Pruim, Jan; Van der Jagt, Eric J; Plukker, John Th; Langendijk, Johannes A

    2009-12-01

    To determine the consequences of target volume (TV) modifications, based on the additional use of PET information, on radiation planning, assuming PET/CT-imaging represents the true extent of the tumour. For 21 patients with esophageal cancer, two separate TV's were retrospectively defined based on CT (CT-TV) and co-registered PET/CT images (PET/CT-TV). Two 3D-CRT plans (prescribed dose 50.4 Gy) were constructed to cover the corresponding TV's. Subsequently, these plans were compared for target coverage, normal tissue dose-volume histograms and the corresponding normal tissue complication probability (NTCP) values. The addition of PET led to the modification of CT-TV with at least 10% in 12 of 21 patients (57%) (reduction in 9, enlargement in 3). PET/CT-TV was inadequately covered by the CT-based treatment plan in 8 patients (36%). Treatment plan modifications resulted in significant changes (p<0.05) in dose distributions to heart and lungs. Corresponding changes in NTCP values ranged from -3% to +2% for radiation pneumonitis and from -0.2% to +1.2% for cardiac mortality. This study demonstrated that TV's based on CT might exclude PET-avid disease. Consequences are under dosing and thereby possibly ineffective treatment. Moreover, the addition of PET in radiation planning might result in clinical important changes in NTCP.

  14. Under-reported dosimetry errors due to interplay effects during VMAT dose delivery in extreme hypofractionated stereotactic radiotherapy.

    PubMed

    Gauer, Tobias; Sothmann, Thilo; Blanck, Oliver; Petersen, Cordula; Werner, René

    2018-06-01

    Radiotherapy of extracranial metastases changed from normofractioned 3D CRT to extreme hypofractionated stereotactic treatment using VMAT beam techniques. Random interaction between tumour motion and dynamically changing beam parameters might result in underdosage of the CTV even for an appropriately dimensioned ITV (interplay effect). This study presents a clinical scenario of extreme hypofractionated stereotactic treatment and analyses the impact of interplay effects on CTV dose coverage. For a thoracic/abdominal phantom with an integrated high-resolution detector array placed on a 4D motion platform, dual-arc treatment plans with homogenous target coverage were created using a common VMAT technique and delivered in a single fraction. CTV underdosage through interplay effects was investigated by comparing dose measurements with and without tumour motion during plan delivery. Our study agrees with previous works that pointed out insignificant interplay effects on target coverage for very regular tumour motion patterns like simple sinusoidal motion. However, we identified and illustrated scenarios that are likely to result in a clinically relevant CTV underdosage. For tumour motion with abnormal variability, target coverage quantified by the CTV area receiving more than 98% of the prescribed dose decreased to 78% compared to 100% at static dose measurement. This study is further proof of considerable influence of interplay effects on VMAT dose delivery in stereotactic radiotherapy. For selected conditions of an exemplary scenario, interplay effects and related motion-induced target underdosage primarily occurred in tumour motion pattern with increased motion variability and VMAT plan delivery using complex MLC dose modulation.

  15. Similar clinical benefits from below-target and target dose enalapril in patients with heart failure in the SOLVD Treatment trial.

    PubMed

    Lam, Phillip H; Dooley, Daniel J; Fonarow, Gregg C; Butler, Javed; Bhatt, Deepak L; Filippatos, Gerasimos S; Deedwania, Prakash; Forman, Daniel E; White, Michel; Fletcher, Ross D; Arundel, Cherinne; Blackman, Marc R; Adamopoulos, Chris; Kanonidis, Ioannis E; Aban, Inmaculada B; Patel, Kanan; Aronow, Wilbert S; Allman, Richard M; Anker, Stefan D; Pitt, Bertram; Ahmed, Ali

    2018-02-01

    To examine associations of below-target and target dose of enalapril, an angiotensin-converting enzyme (ACE) inhibitor, with outcomes in patients with heart failure and reduced ejection fraction (HFrEF) in the Studies of Left Ventricular Dysfunction (SOLVD) Treatment trial. Two thousand five hundred and sixty-nine patients with HFrEF (ejection fraction ≤35%) were randomized to below-target (5-10 mg/day) dose placebo (n = 1284) or enalapril (n = 1285). One month post-randomization, blind up-titration to target (20 mg/day) dose was attempted for both study drugs in 2458 patients. Among the 1444 patients who achieved dose up-titration (placebo, n = 748; enalapril, n = 696; mean dose for both groups, 20.0 mg/day), target dose enalapril (vs. target dose placebo) was associated with a 9% absolute lower risk of the combined endpoint of heart failure hospitalization or all-cause mortality [adjusted hazard ratio (HR) 0.70; 95% confidence interval (CI) 0.60-0.81; P < 0.001] during 4 years of follow-up. Among the 1014 patients who could not achieve target dose (placebo, n = 486; enalapril, n = 528; mean dose for both groups, 8.8 mg/day), below-target dose enalapril (vs. below-target dose placebo) was associated with a 12% absolute lower risk of the combined endpoint of heart failure hospitalization or all-cause mortality (adjusted HR 0.68; 95% CI 0.57-0.81; P < 0.001). Among the 1224 patients receiving enalapril, target (vs. below-target) dose had no association with the combined endpoint of heart failure hospitalization or all-cause mortality (adjusted HR 1.04; 95% CI 0.87-1.23; P = 0.695). In patients with HFrEF, the clinical benefits of ACE inhibitors appear to be similar at both below-target and target doses. © 2017 The Authors. European Journal of Heart Failure © 2017 European Society of Cardiology.

  16. SU-F-T-35: Optimization of Bladder and Rectal Doses Using a Multi-Lumen Intracavitary Applicator for Gynecological Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laoui, S; Dietrich, S; Sehgal, V

    2016-06-15

    Purpose: Radiation dose delivery for endometrial cancer using HDR techniques is limited by dose to bladder and rectum. A dosimetric study was performed using Varian Capri vaginal brachytherapy applicator to determine the optimal channel configuration which minimizes dose to bladder and rectum, while providing good target coverage. Methods: A total of 17 patients, 63 plans clinically delivered, and 252 simulated plans using Varian BrachyVision planning system were generated to investigate optimal channel configuration which results in minimum dose to bladder and rectum while providing adequate target coverage. The Capri applicator consists of 13 lumens arranged in two concentric rings, onemore » central lumen and six lumens per ring. Manual dose shaping is invariably required to lower the dose to critical organs. Three-dimensional plans were simulated for 4 channel arrangements, all 13 channels, channel 12 o’clock (close to bladder) and 6 o’clock (close to rectum) deactivated, central channel deactivated, and central channel in addition to 12 o’clock and 6 o’clock deactivated. A relationship between V100, the volume that receives the prescribed dose, and the amount of curie-seconds required to deliver it, was established. Results: Using all 13 channels results in maximum dose to bladder and rectum. Deactivating central channel in addition to 12 o’clock and 6 o’clock resulted in minimizing bladder and rectum doses but compromised target coverage. The relationship between V100, the volume that receives the prescribed dose, and the curie seconds was found to be linear. Conclusion: Deactivating channels 12 o’clock and 6 o’clock was shown to be the optimal configuration leading to minimum dose to bladder and rectum without compromising target coverage. The linear relationship between V100 and the curie- seconds can be used as a verification parameter.« less

  17. Agonistic TAM-163 antibody targeting tyrosine kinase receptor-B: applying mechanistic modeling to enable preclinical to clinical translation and guide clinical trial design.

    PubMed

    Vugmeyster, Yulia; Rohde, Cynthia; Perreault, Mylene; Gimeno, Ruth E; Singh, Pratap

    2013-01-01

    TAM-163, an agonist monoclonal antibody targeting tyrosine receptor kinase-B (TrkB), is currently being investigated as a potential body weight modulatory agent in humans. To support the selection of the dose range for the first-in-human (FIH) trial of TAM-163, we conducted a mechanistic analysis of the pharmacokinetic (PK) and pharmacodynamic (PD) data (e.g., body weight gain) obtained in lean cynomolgus and obese rhesus monkeys following single doses ranging from 0.3 to 60 mg/kg. A target-mediated drug disposition (TMDD) model was used to describe the observed nonlinear PK and Emax approach was used to describe the observed dose-dependent PD effect. The TMDD model development was supported by the experimental determination of the binding affinity constant (9.4 nM) and internalization rate of the drug-target complex (2.08 h(-1)). These mechanistic analyses enabled linking of exposure, target (TrkB) coverage, and pharmacological activity (e.g., PD) in monkeys, and indicated that ≥ 38% target coverage (time-average) was required to achieve significant body weight gain in monkeys. Based on the scaling of the TMDD model from monkeys to humans and assuming similar relationship between the target coverage and pharmacological activity between monkey and humans, subcutaneous (SC) doses of 1 and 15 mg/kg in humans were projected to be the minimally and the fully pharmacologically active doses, respectively. Based on the minimal anticipated biological effect level (MABEL) approach for starting dose selection, the dose of 0.05 mg/kg (3 mg for a 60 kg human) SC was recommended as the starting dose for FIH trials, because at this dose level<10% target coverage was projected at Cmax (and all other time points). This study illustrates a rational mechanistic approach for the selection of FIH dose range for a therapeutic protein with a complex model of action.

  18. Seasonal influenza vaccine dose distribution in 157 countries (2004-2011).

    PubMed

    Palache, Abraham; Oriol-Mathieu, Valerie; Abelin, Atika; Music, Tamara

    2014-11-12

    Globally there are an estimated 3-5 million cases of severe influenza illness every year, resulting in 250,000-500,000 deaths. At the World Health Assembly in 2003, World Health Organization (WHO) resolved to increase influenza vaccine coverage rates (VCR) for high-risk groups, particularly focusing on at least 75% of the elderly by 2010. But systematic worldwide data have not been available to assist public health authorities to monitor vaccine uptake and review progress toward vaccination coverage targets. In 2008, the International Federation of Pharmaceutical Manufacturers and Associations Influenza Vaccine Supply task force (IFPMA IVS) developed a survey methodology to assess global influenza vaccine dose distribution. The current survey results represent 2011 data and demonstrate the evolution of the absolute number distributed between 2004 and 2011 inclusive, and the evolution in the per capita doses distributed in 2008-2011. Global distribution of IFPMA IVS member doses increased approximately 86.9% between 2004 and 2011, but only approximately 12.1% between 2008 and 2011. The WHO's regions in Eastern Mediterranean (EMRO), Southeast Asian (SEARO) and Africa (AFRO) together account for about 47% of the global population, but only 3.7% of all IFPMA IVS doses distributed. While distributed doses have globally increased, they have decreased in EURO and EMRO since 2009. Dose distribution can provide a reasonable proxy of vaccine utilization. Based on the dose distribution, we conclude that seasonal influenza VCR in many countries remains well below the WHA's VCR targets and below the recommendations of the Council of the European Union in EURO. Inter- and intra-regional disparities in dose distribution trends call into question the impact of current vaccine recommendations at achieving coverage targets. Additional policy measures, particularly those that influence patients adherence to vaccination programs, such as reimbursement, healthcare provider knowledge

  19. Increased immunization coverage addresses the equity gap in Nepal

    PubMed Central

    Nelin, Viktoria; Raaijmakers, Hendrikus; Kim, Hyung Joon; Singh, Chahana; Målqvist, Mats

    2017-01-01

    Abstract Objective To compare immunization coverage and equity distribution of coverage between 2001 and 2014 in Nepal. Methods We used data from the Demographic and Health Surveys carried out in 2001, 2006 and 2011 together with data from the 2014 Multiple Indicator Cluster Survey. We calculated the proportion, in mean percentage, of children who had received bacille Calmette–Guérin (BCG) vaccine, three doses of polio vaccine, three doses of diphtheria–pertussis–tetanus (DPT) vaccine and measles vaccine. To measure inequities between wealth quintiles, we calculated the slope index of inequality (SII) and relative index of inequality (RII) for all surveys. Findings From 2001 to 2014, the proportion of children who received all vaccines at the age of 12 months increased from 68.8% (95% confidence interval, CI: 67.5–70.1) to 82.4% (95% CI: 80.7–84.0). While coverage of BCG, DPT and measles immunization statistically increased during the study period, the proportion of children who received the third dose of polio vaccine decreased from 93.3% (95% CI: 92.7–93.9) to 88.1% (95% CI: 86.8–89.3). The poorest wealth quintile showed the greatest improvement in immunization coverage, from 58% to 77.9%, while the wealthiest quintile only improved from 84.8% to 86.0%. The SII for children who received all vaccines improved from 0.070 (95% CI: 0.061–0.078) to 0.026 (95% CI: 0.013–0.039) and RII improved from 1.13 to 1.03. Conclusion The improvement in immunization coverage between 2001 and 2014 in Nepal can mainly be attributed to the interventions targeting the disadvantaged populations. PMID:28479621

  20. Coverage, efficacy or dosing interval: which factor predominantly influences the impact of routine childhood vaccination for the prevention of varicella? A model-based study for Italy.

    PubMed

    Holl, Katsiaryna; Sauboin, Christophe; Amodio, Emanuele; Bonanni, Paolo; Gabutti, Giovanni

    2016-10-21

    Varicella is a highly infectious disease with a significant public health and economic burden, which can be prevented with childhood routine varicella vaccination. Vaccination strategies differ by country. Some factors are known to play an important role (number of doses, coverage, dosing interval, efficacy and catch-up programmes), however, their relative impact on the reduction of varicella in the population remains unclear. This paper aims to help policy makers prioritise the critical factors to achieve the most successful vaccination programme with the available budget. Scenarios assessed the impact of different vaccination strategies on reduction of varicella disease in the population. A dynamic transmission model was used and adapted to fit Italian demographics and population mixing patterns. Inputs included coverage, number of doses, dosing intervals, first-dose efficacy and availability of catch-up programmes, based on strategies currently used or likely to be used in different countries. The time horizon was 30 years. Both one- and two-dose routine varicella vaccination strategies prevented a comparable number of varicella cases with complications, but two-doses provided broader protection due to prevention of a higher number of milder varicella cases. A catch-up programme in susceptible adolescents aged 10-14 years old reduced varicella cases by 27-43 % in older children, which are often more severe than in younger children. Coverage, for all strategies, sustained at high levels achieved the largest reduction in varicella. In general, a 20 % increase in coverage resulted in a further 27-31 % reduction in varicella cases. When high coverage is reached, the impact of dosing interval and first-dose vaccine efficacy had a relatively lower impact on disease prevention in the population. Compared to the long (11 years) dosing interval, the short (5 months) and medium (5 years) interval schedules reduced varicella cases by a further 5-13 % and 2-5

  1. The influence of performance-based payment on childhood immunisation coverage.

    PubMed

    Merilind, Eero; Salupere, Rauno; Västra, Katrin; Kalda, Ruth

    2015-06-01

    Pay-for-performance, also called the quality system (QS) in Estonia, was implemented in 2006 and one indicator for achievement is the childhood immunisation coverage rate. The WHO vaccination coverage in Europe for diphtheria, tetanus and pertussis, and measles in children aged around one year old should meet or exceed 90 per cent. The study was conducted using a database from the Estonian Health Insurance Fund. The study compared childhood immunisation coverage rates of all Estonian family physicians in two groups, joined and not joined to the quality system during the observation period 2006-2012. Immunisation coverage was calculated as the percentage of persons in the target age group who received a vaccine dose by a given age. The target level of immunisations in Estonia is set at 90 per cent and higher. Immunisation coverage rates of family doctors (FD) in Estonia showed significant differences between two groups of doctors: joined to the quality system and not joined. Doctors joined to the quality system met the 90 per cent vaccination criterion more frequently compared to doctors not joined to the quality system. Doctors not joined to the quality system were below the 90 per cent vaccination criterion in all vaccinations listed in the Estonian State Immunisation Schedule. Pay-for-performance as a financial incentive encourages higher levels of childhood immunisations. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. WE-AB-209-08: Novel Beam-Specific Adaptive Margins for Reducing Organ-At-Risk Doses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsang, H; Kamerling, CP; Ziegenhein, P

    2016-06-15

    Purpose: Current practice of using 3D margins in radiotherapy with high-energy photon beams provides larger-than-required target coverage. According to the photon depth-dose curve, target displacements in beam direction result in minute changes in dose delivered. We exploit this behavior by generating margins on a per-beam basis which simultaneously account for the relative distance of the target and adjacent organs-at-risk (OARs). Methods: For each beam, we consider only geometrical uncertainties of the target location perpendicular to beam direction. By weighting voxels based on its proximity to an OAR, we generate adaptive margins that yield similar overall target coverage probability and reducedmore » OAR dose-burden, at the expense of increased target volume. Three IMRT plans, using 3D margins and 2D per-beam margins with and without adaptation, were generated for five prostate patients with a prescription dose Dpres of 78Gy in 2Gy fractions using identical optimisation constraints. Systematic uncertainties of 1.1, 1.1, 1.5mm in the LR, SI, and AP directions, respectively, and 0.9, 1.1, 1.0mm for the random uncertainties, were assumed. A verification tool was employed to simulate the effects of systematic and random errors using a population size of 50,000. The fraction of the population that satisfies or violates a given DVH constraint was used for comparison. Results: We observe similar target coverage across all plans, with at least 97.5% of the population meeting the D98%>95%Dpres constraint. When looking at the probability of the population receiving D5<70Gy for the rectum, we observed median absolute increases of 23.61% (range, 2.15%–27.85%) and 6.97% (range, 0.65%–17.76%) using per-beam margins with and without adaptation, respectively, relative to using 3D margins. Conclusion: We observed sufficient and similar target coverage using per-beam margins. By adapting each per-beam margin away from an OAR, we can further reduce OAR dose without

  3. Glandular radiation dose in tomosynthesis of the breast using tungsten targets.

    PubMed

    Sechopoulos, Ioannis; D'Orsi, Carl J

    2008-10-24

    With the advent of new detector technology, digital tomosynthesis imaging of the breast has, in the past few years, become a technique intensely investigated as a replacement for planar mammography. As with all other x-ray-based imaging methods, radiation dose is of utmost concern in the development of this new imaging technology. For virtually all development and optimization studies, knowledge of the radiation dose involved in an imaging protocol is necessary. A previous study characterized the normalized glandular dose in tomosynthesis imaging and its variation with various breast and imaging system parameters. This characterization was performed with x-ray spectra generated by molybdenum and rhodium targets. In the recent past, many preliminary patient studies of tomosynthesis imaging have been reported in which the x-ray spectra were generated with x-ray tubes with tungsten targets. The differences in x-ray distribution among spectra from these target materials make the computation of new normalized glandular dose values for tungsten target spectra necessary. In this study we used previously obtained monochromatic normalized glandular dose results to obtain spectral results for twelve different tungsten target x-ray spectra. For each imaging condition, two separate values were computed: the normalized glandular dose for the zero degree projection angle (DgN0), and the ratio of the glandular dose for non-zero projection angles to the glandular dose for the zero degree projection (the relative glandular dose, RGD(alpha)). It was found that DgN0 is higher for tungsten target x-ray spectra when compared with DgN0 values for molybdenum and rhodium target spectra of both equivalent tube voltage and first half value layer. Therefore, the DgN0 for the twelve tungsten target x-ray spectra and different breast compositions and compressed breast thicknesses simulated are reported. The RGD(alpha) values for the tungsten spectra vary with the parameters studied in a

  4. Using health-facility data to assess subnational coverage of maternal and child health indicators, Kenya.

    PubMed

    Maina, Isabella; Wanjala, Pepela; Soti, David; Kipruto, Hillary; Droti, Benson; Boerma, Ties

    2017-10-01

    To develop a systematic approach to obtain the best possible national and subnational statistics for maternal and child health coverage indicators from routine health-facility data. Our approach aimed to obtain improved numerators and denominators for calculating coverage at the subnational level from health-facility data. This involved assessing data quality and determining adjustment factors for incomplete reporting by facilities, then estimating local target populations based on interventions with near-universal coverage (first antenatal visit and first dose of pentavalent vaccine). We applied the method to Kenya at the county level, where routine electronic reporting by facilities is in place via the district health information software system. Reporting completeness for facility data were well above 80% in all 47 counties and the consistency of data over time was good. Coverage of the first dose of pentavalent vaccine, adjusted for facility reporting completeness, was used to obtain estimates of the county target populations for maternal and child health indicators. The country and national statistics for the four-year period 2012/13 to 2015/16 showed good consistency with results of the 2014 Kenya demographic and health survey. Our results indicated a stagnation of immunization coverage in almost all counties, a rapid increase of facility-based deliveries and caesarean sections and limited progress in antenatal care coverage. While surveys will continue to be necessary to provide population-based data, web-based information systems for health facility reporting provide an opportunity for more frequent, local monitoring of progress, in maternal and child health.

  5. Analysis of nodal coverage utilizing image guided radiation therapy for primary gynecologic tumor volumes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmed, Faisal; Loma Linda University Medical Center, Department of Radiation Oncology, Loma Linda, CA; Sarkar, Vikren

    Purpose: To evaluate radiation dose delivered to pelvic lymph nodes, if daily Image Guided Radiation Therapy (IGRT) was implemented with treatment shifts based on the primary site (primary clinical target volume [CTV]). Our secondary goal was to compare dosimetric coverage with patient outcomes. Materials and methods: A total of 10 female patients with gynecologic malignancies were evaluated retrospectively after completion of definitive intensity-modulated radiation therapy (IMRT) to their pelvic lymph nodes and primary tumor site. IGRT consisted of daily kilovoltage computed tomography (CT)-on-rails imaging fused with initial planning scans for position verification. The initial plan was created using Varian's Eclipsemore » treatment planning software. Patients were treated with a median radiation dose of 45 Gy (range: 37.5 to 50 Gy) to the primary volume and 45 Gy (range: 45 to 64.8 Gy) to nodal structures. One IGRT scan per week was randomly selected from each patient's treatment course and re-planned on the Eclipse treatment planning station. CTVs were recreated by fusion on the IGRT image series, and the patient's treatment plan was applied to the new image set to calculate delivered dose. We evaluated the minimum, maximum, and 95% dose coverage for primary and nodal structures. Reconstructed primary tumor volumes were recreated within 4.7% of initial planning volume (0.9% to 8.6%), and reconstructed nodal volumes were recreated to within 2.9% of initial planning volume (0.01% to 5.5%). Results: Dosimetric parameters averaged less than 10% (range: 1% to 9%) of the original planned dose (45 Gy) for primary and nodal volumes on all patients (n = 10). For all patients, ≥99.3% of the primary tumor volume received ≥ 95% the prescribed dose (V95%) and the average minimum dose was 96.1% of the prescribed dose. In evaluating nodal CTV coverage, ≥ 99.8% of the volume received ≥ 95% the prescribed dose and the average minimum dose was 93%. In evaluating

  6. SU-E-T-480: Radiobiological Dose Comparison of Single Fraction SRS, Multi-Fraction SRT and Multi-Stage SRS of Large Target Volumes Using the Linear-Quadratic Formula

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, C; Hrycushko, B; Jiang, S

    2014-06-01

    Purpose: To compare the radiobiological effect on large tumors and surrounding normal tissues from single fraction SRS, multi-fractionated SRT, and multi-staged SRS treatment. Methods: An anthropomorphic head phantom with a centrally located large volume target (18.2 cm{sup 3}) was scanned using a 16 slice large bore CT simulator. Scans were imported to the Multiplan treatment planning system where a total prescription dose of 20Gy was used for a single, three staged and three fractionated treatment. Cyber Knife treatment plans were inversely optimized for the target volume to achieve at least 95% coverage of the prescription dose. For the multistage plan,more » the target was segmented into three subtargets having similar volume and shape. Staged plans for individual subtargets were generated based on a planning technique where the beam MUs of the original plan on the total target volume are changed by weighting the MUs based on projected beam lengths within each subtarget. Dose matrices for each plan were export in DICOM format and used to calculate equivalent dose distributions in 2Gy fractions using an alpha beta ratio of 10 for the target and 3 for normal tissue. Results: Singe fraction SRS, multi-stage plan and multi-fractionated SRT plans had an average 2Gy dose equivalent to the target of 62.89Gy, 37.91Gy and 33.68Gy, respectively. The normal tissue within 12Gy physical dose region had an average 2Gy dose equivalent of 29.55Gy, 16.08Gy and 13.93Gy, respectively. Conclusion: The single fraction SRS plan had the largest predicted biological effect for the target and the surrounding normal tissue. The multi-stage treatment provided for a more potent biologically effect on target compared to the multi-fraction SRT treatments with less biological normal tissue than single-fraction SRS treatment.« less

  7. Vaccination coverage survey in Dhaka District.

    PubMed

    Khan, M N A; Rahman, M L; Awal Miah, A; Islam, M S; Musa, S A J M; Tofail, F

    2005-08-01

    A survey was conducted in Dhaka District to measure the level of routine immunization coverage of children (12-23 months), to assess the tetanus toxoid (TT) immunization coverage among mothers of children (12-23 month), to evaluate EPI program continuity (dropout rates) and quality (percent of Invalid doses, vaccination card availability etc.) For this purpose, a thirty cluster cross-sectional survey was conducted in October 2002 to assess the immunization coverage in Dhaka. In this survey 30 clusters were randomly selected from a list of villages in 63 Unions of Dhaka following probability proportion to size (PPS) sampling procedure. A total of 210 children was studied using pre-tested structured questionnaire. Descriptive statistics was employed using software SPSS package for data analysis. The study showed that the routine immunization coverage in Dhaka among children by 12 months of age by card + history was 97% for BCG, 97% for Diphtheria, Pertussis Tetanus (DPT 1) and Oral Polio Vaccine (OPV 1), 75% for DPT3 and OPV3 and 67% for measles. Sixty six percent of all children surveyed had received valid doses of all vaccines by 12 months (fully immunized child). Programme access as measured by crude DPT1 coverage was better in Keranigonj (97%). Vaccination cards retention rate for children was 84%. Invalid DPT (1,2 or 3) doses were given to 25% of vaccinated children; 18% of measles doses were invalid. Surprisingly, major cause for invalid doses were not due to early immunizations or due to card lost but for giving tick in the card, instead of writing a valid date. DPT1 and DPT3 and DPT1- Measles drop out rates were 5% and 13% respectively. Major reason parents gave for never vaccinating their children (zero dose children) was (43%), major reasons for incomplete vaccination was lack of knowledge regarding subsequent doses (46%). TT surveys were also conducted for mothers of the children surveyed for vaccination coverage (mothers between 15-49 year old). Valid TT

  8. Transfer of genetic therapy across human populations: molecular targets for increasing patient coverage in repeat expansion diseases

    PubMed Central

    Varela, Miguel A; Curtis, Helen J; Douglas, Andrew GL; Hammond, Suzan M; O'Loughlin, Aisling J; Sobrido, Maria J; Scholefield, Janine; Wood, Matthew JA

    2016-01-01

    Allele-specific gene therapy aims to silence expression of mutant alleles through targeting of disease-linked single-nucleotide polymorphisms (SNPs). However, SNP linkage to disease varies between populations, making such molecular therapies applicable only to a subset of patients. Moreover, not all SNPs have the molecular features necessary for potent gene silencing. Here we provide knowledge to allow the maximisation of patient coverage by building a comprehensive understanding of SNPs ranked according to their predicted suitability toward allele-specific silencing in 14 repeat expansion diseases: amyotrophic lateral sclerosis and frontotemporal dementia, dentatorubral-pallidoluysian atrophy, myotonic dystrophy 1, myotonic dystrophy 2, Huntington's disease and several spinocerebellar ataxias. Our systematic analysis of DNA sequence variation shows that most annotated SNPs are not suitable for potent allele-specific silencing across populations because of suboptimal sequence features and low variability (>97% in HD). We suggest maximising patient coverage by selecting SNPs with high heterozygosity across populations, and preferentially targeting SNPs that lead to purine:purine mismatches in wild-type alleles to obtain potent allele-specific silencing. We therefore provide fundamental knowledge on strategies for optimising patient coverage of therapeutics for microsatellite expansion disorders by linking analysis of population genetic variation to the selection of molecular targets. PMID:25990798

  9. Transfer of genetic therapy across human populations: molecular targets for increasing patient coverage in repeat expansion diseases.

    PubMed

    Varela, Miguel A; Curtis, Helen J; Douglas, Andrew G L; Hammond, Suzan M; O'Loughlin, Aisling J; Sobrido, Maria J; Scholefield, Janine; Wood, Matthew J A

    2016-02-01

    Allele-specific gene therapy aims to silence expression of mutant alleles through targeting of disease-linked single-nucleotide polymorphisms (SNPs). However, SNP linkage to disease varies between populations, making such molecular therapies applicable only to a subset of patients. Moreover, not all SNPs have the molecular features necessary for potent gene silencing. Here we provide knowledge to allow the maximisation of patient coverage by building a comprehensive understanding of SNPs ranked according to their predicted suitability toward allele-specific silencing in 14 repeat expansion diseases: amyotrophic lateral sclerosis and frontotemporal dementia, dentatorubral-pallidoluysian atrophy, myotonic dystrophy 1, myotonic dystrophy 2, Huntington's disease and several spinocerebellar ataxias. Our systematic analysis of DNA sequence variation shows that most annotated SNPs are not suitable for potent allele-specific silencing across populations because of suboptimal sequence features and low variability (>97% in HD). We suggest maximising patient coverage by selecting SNPs with high heterozygosity across populations, and preferentially targeting SNPs that lead to purine:purine mismatches in wild-type alleles to obtain potent allele-specific silencing. We therefore provide fundamental knowledge on strategies for optimising patient coverage of therapeutics for microsatellite expansion disorders by linking analysis of population genetic variation to the selection of molecular targets.

  10. Fetal radiation monitoring and dose minimization during intensity modulated radiation therapy for glioblastoma in pregnancy.

    PubMed

    Horowitz, David P; Wang, Tony J C; Wuu, Cheng-Shie; Feng, Wenzheng; Drassinower, Daphnie; Lasala, Anita; Pieniazek, Radoslaw; Cheng, Simon; Connolly, Eileen P; Lassman, Andrew B

    2014-11-01

    We examined the fetal dose from irradiation of glioblastoma during pregnancy using intensity modulated radiation therapy (IMRT), and describe fetal dose minimization using mobile shielding devices. A case report is described of a pregnant woman with glioblastoma who was treated during the third trimester of gestation with 60 Gy of radiation delivered via a 6 MV photon IMRT plan. Fetal dose without shielding was estimated using an anthropomorphic phantom with ion chamber and diode measurements. Clinical fetal dose with shielding was determined with optically stimulated luminescent dosimeters and ion chamber. Clinical target volume (CTV) and planning target volume (PTV) coverage was 100 and 98 % receiving 95 % of the prescription dose, respectively. Normal tissue tolerances were kept below quantitative analysis of normal tissue effects in the clinic (QUANTEC) recommendations. Without shielding, anthropomorphic phantom measurements showed a cumulative fetal dose of 0.024 Gy. In vivo measurements with shielding in place demonstrated a cumulative fetal dose of 0.016 Gy. The fetal dose estimated without shielding was 0.04 % and with shielding was 0.026 % of the target dose. In vivo estimation of dose equivalent received by the fetus was 24.21 mSv. Using modern techniques, brain irradiation can be delivered to pregnant patients in the third trimester with very low measured doses to the fetus, without compromising target coverage or normal tissue dose constraints. Fetal dose can further be reduced with the use of shielding devices, in keeping with the principle of as low as reasonably achievable.

  11. Fully automated treatment planning for head and neck radiotherapy using a voxel-based dose prediction and dose mimicking method

    NASA Astrophysics Data System (ADS)

    McIntosh, Chris; Welch, Mattea; McNiven, Andrea; Jaffray, David A.; Purdie, Thomas G.

    2017-08-01

    Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present a probabilistic, atlas-based approach which predicts the dose for novel patients using a set of automatically selected most similar patients (atlases). The output is a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces the need to specify and tune dose-volume objectives. Voxel-based dose mimicking optimization then converts the predicted dose distribution to a complete treatment plan with dose calculation using a collapsed cone convolution dose engine. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients by evaluating 14 clinical dose evaluation criteria. Our preliminary results are promising and demonstrate that automated methods can generate comparable dose distributions to clinical. Overall, automated plans achieved an average of 0.6% higher dose for target coverage evaluation criteria, and 2.4% lower dose at the organs at risk criteria levels evaluated compared with clinical. There was no statistically significant difference detected in high-dose conformity between automated and clinical plans as measured by the conformation number. Automated plans achieved nine more unique criteria than clinical across the 12 patients tested and automated plans scored a significantly higher dose at the evaluation limit for two high-risk target coverage criteria and a significantly lower dose in one critical organ maximum dose. The novel dose prediction method with dose mimicking can generate complete treatment plans in 12-13 min without user interaction. It is a promising approach for fully automated treatment

  12. Fully automated treatment planning for head and neck radiotherapy using a voxel-based dose prediction and dose mimicking method.

    PubMed

    McIntosh, Chris; Welch, Mattea; McNiven, Andrea; Jaffray, David A; Purdie, Thomas G

    2017-07-06

    Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present a probabilistic, atlas-based approach which predicts the dose for novel patients using a set of automatically selected most similar patients (atlases). The output is a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces the need to specify and tune dose-volume objectives. Voxel-based dose mimicking optimization then converts the predicted dose distribution to a complete treatment plan with dose calculation using a collapsed cone convolution dose engine. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients by evaluating 14 clinical dose evaluation criteria. Our preliminary results are promising and demonstrate that automated methods can generate comparable dose distributions to clinical. Overall, automated plans achieved an average of 0.6% higher dose for target coverage evaluation criteria, and 2.4% lower dose at the organs at risk criteria levels evaluated compared with clinical. There was no statistically significant difference detected in high-dose conformity between automated and clinical plans as measured by the conformation number. Automated plans achieved nine more unique criteria than clinical across the 12 patients tested and automated plans scored a significantly higher dose at the evaluation limit for two high-risk target coverage criteria and a significantly lower dose in one critical organ maximum dose. The novel dose prediction method with dose mimicking can generate complete treatment plans in 12-13 min without user interaction. It is a promising approach for fully automated treatment

  13. PREDICTING THE RISKS OF NEUROTOXIC VOLATILE ORGANIC COMPOUNDS BASED ON TARGET TISSUE DOSE.

    EPA Science Inventory

    Quantitative exposure-dose-response models relate the external exposure of a substance to the dose in the target tissue, and then relate the target tissue dose to production of adverse outcomes. We developed exposure-dose-response models to describe the affects of acute exposure...

  14. Evaluation of potentially achievable vaccination coverage of the second dose of measles containing vaccine with simultaneous administration and risk factors for missed opportunities among children in Zhejiang province, east China.

    PubMed

    Hu, Yu; Chen, Yaping; Wang, Ying; Liang, Hui

    2018-04-03

    This study aimed to evaluate the potential achievable coverage of the second dose of measles containing vaccine (MCV2) when the protocol of simultaneous administration of childhood vaccines was fully implemented. Risk factors for missed opportunity (MO) for simultaneous administration of MCV2 were also investigated. Children born from 1 January 2005 to 31 December 2014 and registered in Zhejiang provincial immunization information system were enrolled in this study. The MO of simultaneous administration of MCV2, the actual age-appropriate coverage (AAC) of MCV2 and the potentially achievable coverage (PAC) of MCV2 were evaluated and compared across different birth cohorts, by different socio-demographic variables. For the 2014 birth cohort, logistic regression model was used to detect the risk factors of MOs, from both socio-demographic and vaccination service providing aspects. Compared to the AAC, the PAC of MCV2 increased significantly from 2005 birth cohort to 2014 birth cohort (p<0.001), with a median of 12.7 percentage points. Higher birth order of children, resident children, higher maternal education background, higher socio-economic development level of resident areas, less frequent vaccination service, and shorter vaccination service time were significant risk factors of MO for simultaneous administration of MCV2, with all p-value < 0.05. The findings in this study suggest that fully utilization of all opportunities for simultaneous administration of all age-eligible vaccine doses at the same vaccination visit is critical for achieving the coverage target of 95% for MCV2. Future interventions focusing on the group with risk factors observed could substantially eliminate MOs for simultaneous administration of MCV2, further to improve the coverage of fully immunization of MCV, and finally achieve the goal of eliminating measles.

  15. MO-D-213-04: The Proximity to the Skin of PTV Affects PTV Coverage and Skin Dose for TomoTherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reynolds, T; Higgins, P; Watanabe, Y

    Purpose: The proximity to the skin surface of the PTV for the patients with skin disease could be a concern in terms of the PTV coverage and actual surface dose (SD). IMRT optimization algorithms increase the beam intensity close to the skin in order to compensate for lack of scattering material, leading to enhanced SD but potential hot spots. This study aims to investigate the effect of PTV proximity to the skin on planning and measured SD Methods: All measurements were done for 6 MV X-ray beam of Helical TomoTherapy. An anthropomorphic phantom was scanned in a CT simulator inmore » a routine manner with thermoplastic mask immobilization. PTVs were created with varying distances to the skin of 0 mm -(PTV1), 1 mm- (PTV2), 2 mm-(PTV3) and 3 mm-(PTV4). Also, a 5 mm bolus was used with PTV1 (PTV5). All planning constraints were kept the same in all studies (hard constraint: 95% of the prescription dose covered 95% of the PTV). Gafchromic film (EBT3) was placed under the mask on the phantom surface, and the resulting dose was estimated using RIT software. Results: Optimizing the dose using different PTVs lead to average planned target doses of 10.8, 10.3, 10.2, 10.3 and 10.0 Gy, with maximum doses 12.2, 11.2, 11.1, 11.1 and 10.0 Gy for PTV1, PTV2, PTV3, PTV4 and PTV5, respectively. EBT3 measurements indicated a significant decrease of SD with skin distance by 12.7% (PTV1), 21.9% (PTV2), 24.8% (PTV3) and 28.4% (PTV4) comparing to prescription dose. Placement of a 5 mm bolus on the phantom surface resulted in a SD close to prescribed (+0.5%). Conclusion: This work provides a clear demonstration of the relationship between the skin dose and the PTV to the skin distance. The results indicate the necessity of a bolus even for TomoTherapy when high skin dose is required.« less

  16. TU-AB-BRB-03: Coverage-Based Treatment Planning to Accommodate Organ Deformable Motions and Contouring Uncertainties for Prostate Treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, H.

    The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. Themore » treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To

  17. Intensity-modulated radiotherapy improves lymph node coverage and dose to critical structures compared with three-dimensional conformal radiation therapy in clinically localized prostate cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang-Chesebro, Alice; Xia Ping; Coleman, Joy

    2006-11-01

    Purpose: The aim of this study was to quantify gains in lymph node coverage and critical structure dose reduction for whole-pelvis (WP) and extended-field (EF) radiotherapy in prostate cancer using intensity-modulated radiotherapy (IMRT) compared with three-dimensional conformal radiotherapy (3DCRT) for the first treatment phase of 45 Gy in the concurrent treatment of lymph nodes and prostate. Methods and Materials: From January to August 2005, 35 patients with localized prostate cancer were treated with pelvic IMRT; 7 had nodes defined up to L5-S1 (Group 1), and 28 had nodes defined above L5-S1 (Group 2). Each patient had 2 plans retrospectively generated:more » 1 WP 3DCRT plan using bony landmarks, and 1 EF 3DCRT plan to cover the vascular defined volumes. Dose-volume histograms for the lymph nodes, rectum, bladder, small bowel, and penile bulb were compared by group. Results: For Group 1, WP 3DCRT missed 25% of pelvic nodes with the prescribed dose 45 Gy and missed 18% with the 95% prescribed dose 42.75 Gy, whereas WP IMRT achieved V{sub 45Gy} = 98% and V{sub 42.75Gy} = 100%. Compared with WP 3DCRT, IMRT reduced bladder V{sub 45Gy} by 78%, rectum V{sub 45Gy} by 48%, and small bowel V{sub 45Gy} by 232 cm{sup 3}. EF 3DCRT achieved 95% coverage of nodes for all patients at high cost to critical structures. For Group 2, IMRT decreased bladder V{sub 45Gy} by 90%, rectum V{sub 45Gy} by 54% and small bowel V{sub 45Gy} by 455 cm{sup 3} compared with EF 3DCRT. Conclusion: In this study WP 3DCRT missed a significant percentage of pelvic nodes. Although EF 3DCRT achieved 95% pelvic nodal coverage, it increased critical structure doses. IMRT improved pelvic nodal coverage while decreasing dose to bladder, rectum, small bowel, and penile bulb. For patients with extended node involvement, IMRT especially decreases small bowel dose.« less

  18. SU-F-19A-03: Dosimetric Advantages in Critical Structure Dose Sparing by Using a Multichannel Cylinder in High Dose Rate Brachytherapy to Treat Vaginal Cuff Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Syh, J; Syh, J; Patel, B

    2014-06-15

    Purpose: The multichannel cylindrical vaginal applicator is a variation of traditional single channel cylindrical vaginal applicator. The multichannel applicator has additional peripheral channels that provide more flexibility in the planning process. The dosimetric advantage is to reduce dose to adjacent organ at risk (OAR) such as bladder and rectum while maintaining target coverage with the dose optimization from additional channels. Methods: Vaginal HDR brachytherapy plans are all CT based. CT images were acquired in 2 mm thickness to keep integrity of cylinder contouring. The CTV of 5mm Rind with prescribed treatment length was reconstructed from 5mm expansion of inserted cylinder.more » The goal was 95% of CTV covered by 95% of prescribed dose in both single channel planning (SCP)and multichannel planning (MCP) before proceeding any further optimization for dose reduction to critical structures with emphasis on D2cc and V2Gy . Results: This study demonstrated noticeable dose reduction to OAR was apparent in multichannel plans. The D2cc of the rectum and bladder were showing the reduced dose for multichannel versus single channel. The V2Gy of the rectum was 93.72% and 83.79% (p=0.007) for single channel and multichannel respectively (Figure 1 and Table 1). To assure adequate coverage to target while reducing the dose to the OAR without any compromise is the main goal in using multichannel vaginal applicator in HDR brachytherapy. Conclusion: Multichannel plans were optimized using anatomical based inverse optimization algorithm of inverse planning simulation annealing. The optimization solution of the algorithm was to improve the clinical target volume dose coverage while reducing the dose to critical organs such as bladder, rectum and bowels. The comparison between SCP and MCP demonstrated MCP is superior to SCP where the dwell positions were based on geometric array only. It concluded that MCP is preferable and is able to provide certain features superior

  19. Vaccination against meningococcus C. vaccinal coverage in the French target population.

    PubMed

    Stahl, J-P; Cohen, R; Denis, F; Gaudelus, J; Lery, T; Lepetit, H; Martinot, A

    2013-02-01

    Immunization against meningococcus C has been recommended in France since 2009 (infants from 12 to 24 months of age, and catch up vaccination up to 25 years of age). It has been reimbursed since January 2010. We had for aim to assess the vaccine coverage in 2011. The study population included mothers of children targeted by the recommendation. They were recruited using Internet data (quotas based on the French National Institute of Statistics (INSEE) data based on a census made in 2007) based on the Institut des Mamans panel and its partners. The mothers had completed a standardized questionnaire and reported all vaccinations mentioned in their child's health-record. We included 3000 mothers of children, 0 to 35 months of age, (1000 for each of the following age range: 0-11 months, 12-23 months, 24-35 months), and 2250 mothers of teenagers, 14 to 16 years of age. Vaccination was deemed "essential/useful" for respectively 90.2% (CI 95%: 89.2-91.3) and 87.8% (CI 95%: 86.4-89.2) of mothers. Vaccine coverage levels were 32.3% (12-23 months), 57.3% (24-35 months), and 21.3% (14-16 years). Two years after the Ministry of Health's decision to reimburse this vaccine, vaccine coverage levels were much lower than they should have been, to expect effectiveness of the vaccination policy. Only 21.3% of teenagers had been vaccinated, and 32.3% of infants during the second year of life. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  20. SU-F-T-81: Treating Nose Skin Using Energy and Intensity Modulated Electron Beams with Monte Carlo Based Dose Calculation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jin, L; Fan, J; Eldib, A

    Purpose: Treating nose skin with an electron beam is of a substantial challenge due to uneven nose surfaces and tissue heterogeneity, and consequently could have a great uncertainty of dose accuracy on the target. This work explored the method using Monte Carlo (MC)-based energy and intensity modulated electron radiotherapy (MERT), which would be delivered with a photon MLC in a standard medical linac (Artiste). Methods: The traditional treatment on the nose skin involves the usage of a bolus, often with a single energy electron beam. This work avoided using the bolus, and utilized mixed energies of electron beams. An in-housemore » developed Monte Carlo (MC)-based dose calculation/optimization planning system was employed for treatment planning. Phase space data (6, 9, 12 and 15 MeV) were used as an input source for MC dose calculations for the linac. To reduce the scatter-caused penumbra, a short SSD (61 cm) was used. A clinical case of the nose skin, which was previously treated with a single 9 MeV electron beam, was replanned with the MERT method. The resultant dose distributions were compared with the plan previously clinically used. The dose volume histogram of the MERT plan is calculated to examine the coverage of the planning target volume (PTV) and critical structure doses. Results: The target coverage and conformality in the MERT plan are improved as compared to the conventional plan. The MERT can provide more sufficient target coverage and less normal tissue dose underneath the nose skin. Conclusion: Compared to the conventional treatment technique, using MERT for the nose skin treatment has shown the dosimetric advantages in the PTV coverage and conformality. In addition, this technique eliminates the necessity of the cutout and bolus, which makes the treatment more efficient and accurate.« less

  1. Absorbed dose in target cell nuclei and dose conversion coefficient of radon progeny in the human lung.

    PubMed

    Nikezic, D; Lau, B M F; Stevanovic, N; Yu, K N

    2006-01-01

    To calculate the absorbed dose in the human lung due to inhaled radon progeny, ICRP focussed on the layers containing the target cells, i.e., the basal and secretory cells. Such an approach did not consider details of the sensitive cells in the layers. The present work uses the microdosimetric approach and determines the absorbed alpha-particle energy in non-spherical nuclei of target cells (basal and secretory cells). The absorbed energy for alpha particles emitted by radon progeny in the human respiratory tract was calculated in basal- and secretory-cell nuclei, assuming conical and ellipsoidal forms for these cells. Distributions of specific energy for different combinations of alpha-particle sources, energies and targets are calculated and shown. The dose conversion coefficient for radon progeny is reduced for about 2mSv/WLM when conical and ellipsoidal cell nuclei are considered instead of the layers. While changes in the geometry of secretory-cell nuclei do not have significant effects on their absorbed dose, changes from spherical to conical basal-cell nuclei have significantly reduced their absorbed dose from approximately 4 to approximately 3mGy/WLM. This is expected because basal cells are situated close to the end of the range of 6MeV alpha particles. This also underlines the significance of better and more precise information on targets in the T-B tree. A further change in the dose conversion coefficient can be achieved if a different weighting scheme is adopted for the doses for the cells. The results demonstrate the necessity for better information on the target cells for more accurate dosimetry for radon progeny.

  2. NSW annual immunisation coverage report, 2010.

    PubMed

    Hull, Brynley; Dey, Aditi; Campbell-Lloyd, Sue; Menzies, Robert I; McIntyre, Peter B

    2011-11-01

    This annual report, the second in the series, documents trends in immunisation coverage in NSW for children, adolescents and the elderly, to the end of 2010. Data from the Australian Childhood Immunisation Register, the NSW School Immunisation Program and the NSW Population Health Survey were used to calculate various measures of population coverage, coverage for Aboriginal children and vaccination timeliness for all children. Over 90% coverage has been reached for children at 12 and 24 months of age. For children at 5 years of age there was an improvement during 2010 in timeliness for vaccines due at 4 years and coverage almost reached 90%. Delayed receipt of vaccines is still an issue for Aboriginal children. For adolescents, there is good coverage for the first and second doses of human papillomavirus vaccine and the dose of diphtheria, tetanus and acellular pertussis. The pneumococcal vaccination rate in the elderly has been steadily rising, although it has remained lower than the influenza coverage estimates. Completion of the recommended immunisation schedule at the earliest appropriate age should be the next public health goal at both the state and local health district level. Official coverage assessments for 'fully immunised' should include the 7-valent pneumococcal conjugate and meningococcal C vaccines, and wider dissemination should be considered.

  3. Spot Weight Adaptation for Moving Target in Spot Scanning Proton Therapy.

    PubMed

    Morel, Paul; Wu, Xiaodong; Blin, Guillaume; Vialette, Stéphane; Flynn, Ryan; Hyer, Daniel; Wang, Dongxu

    2015-01-01

    This study describes a real-time spot weight adaptation method in spot-scanning proton therapy for moving target or moving patient, so that the resultant dose distribution closely matches the planned dose distribution. The method proposed in this study adapts the weight (MU) of the delivering pencil beam to that of the target spot; it will actually hit during patient/target motion. The target spot that a certain delivering pencil beam may hit relies on patient monitoring and/or motion modeling using four-dimensional (4D) CT. After the adapted delivery, the required total weight [Monitor Unit (MU)] for this target spot is then subtracted from the planned value. With continuous patient motion and continuous spot scanning, the planned doses to all target spots will eventually be all fulfilled. In a proof-of-principle test, a lung case was presented with realistic temporal and motion parameters; the resultant dose distribution using spot weight adaptation was compared to that without using this method. The impact of the real-time patient/target position tracking or prediction was also investigated. For moderate motion (i.e., mean amplitude 0.5 cm), D95% to the planning target volume (PTV) was only 81.5% of the prescription (RX) dose; with spot weight adaptation PTV D95% achieves 97.7% RX. For large motion amplitude (i.e., 1.5 cm), without spot weight adaptation PTV D95% is only 42.9% of RX; with spot weight adaptation, PTV D95% achieves 97.7% RX. Larger errors in patient/target position tracking or prediction led to worse final target coverage; an error of 3 mm or smaller in patient/target position tracking is preferred. The proposed spot weight adaptation method was able to deliver the planned dose distribution and maintain target coverage when patient motion was involved. The successful implementation of this method would rely on accurate monitoring or prediction of patient/target motion.

  4. The Role of High Dose Interleukin-2 in the Era of Targeted Therapy.

    PubMed

    Gills, Jessie; Parker, William P; Pate, Scott; Niu, Sida; Van Veldhuizen, Peter; Mirza, Moben; Holzbeierlein, Jeffery M; Lee, Eugene K

    2017-09-01

    We assessed survival outcomes following high dose interleukin-2 in a contemporary cohort of patients during the era of targeted agents. We retrospectively reviewed the records of patients with metastatic renal cell carcinoma treated with high dose interleukin-2 between July 2007 and September 2014. Clinicopathological data were abstracted and patient response to therapy was based on RECIST (Response Evaluation Criteria In Solid Tumors), version 1.1 criteria. The Kaplan-Meier method was used to estimate progression-free and overall survival in the entire cohort, the response to high dose interleukin-2 in regard to previous targeted agent therapy and the response to the targeted agent in relation to the response to high dose interleukin-2. We identified 92 patients, of whom 87 had documentation of a response to high dose interleukin-2. Median overall survival was 34.4 months from the initiation of high dose interleukin-2 therapy in the entire cohort. Patients who received targeted therapy before high dose interleukin-2 had overall survival (median 34.4 and 30.0 months, p = 0.88) and progression-free survival (median 1.5 and 1.7 months, p = 0.8) similar to those in patients who received no prior therapy, respectively. Additionally, patients with a complete or partial response to high dose interleukin-2 had similar outcomes for subsequent targeted agents compared to patients whose best response was stable or progressive disease (median overall survival 30.1 vs 25.4 months, p = 0.4). Our data demonstrate that patient responses to high dose interleukin-2 and to targeted agents before and after receiving high dose interleukin-2 are independent. As such, carefully selected patients should be offered high dose interleukin-2 for the possibility of a complete and durable response without the fear of limiting the treatment benefit of targeted agents. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  5. SU-E-T-09: A Clinical Implementation and Optimized Dosimetry Study of Freiberg Flap Skin Surface Treatment in High Dose Rate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Syh, J; Syh, J; Patel, B

    Purpose: This case study was designated to confirm the optimized plan was used to treat skin surface of left leg in three stages. 1. To evaluate dose distribution and plan quality by alternating of the source loading catheters pattern in flexible Freiberg Flap skin surface (FFSS) applicator. 2. To investigate any impact on Dose Volume Histogram (DVH) of large superficial surface target volume coverage. 3. To compare the dose distribution if it was treated with electron beam. Methods: The Freiburg Flap is a flexible mesh style surface mold for skin radiation or intraoperative surface treatments. The Freiburg Flap consists ofmore » multiple spheres that are attached to each other, holding and guiding up to 18 treatment catheters. The Freiburg Flap also ensures a constant distance of 5mm from the treatment catheter to the surface. Three treatment trials with individual planning optimization were employed: 18 channels, 9 channels of FF and 6 MeV electron beam. The comparisons were highlighted in target coverage, dose conformity and dose sparing of surrounding tissues. Results: The first 18 channels brachytherapy plan was generated with 18 catheters inside the skin-wrapped up flap (Figure 1A). A second 9 catheters plan was generated associated with the same calculation points which were assigned to match prescription for target coverage as 18 catheters plan (Figure 1B). The optimized inverse plan was employed to reduce the dose to adjacent structures such as tibia or fibula. The comparison of DVH’s was depicted on Figure 2. External beam of electron RT plan was depicted in Figure 3. Overcall comparisons among these three were illustrated in Conclusion: The 9-channel Freiburg flap flexible skin applicator offers a reasonably acceptable plan without compromising the coverage. Electron beam was discouraged to use to treat curved skin surface because of low target coverage and high dose in adjacent tissues.« less

  6. Lot quality assurance sampling for monitoring coverage and quality of a targeted condom social marketing programme in traditional and non-traditional outlets in India

    PubMed Central

    Piot, Bram; Navin, Deepa; Krishnan, Nattu; Bhardwaj, Ashish; Sharma, Vivek; Marjara, Pritpal

    2010-01-01

    Objectives This study reports on the results of a large-scale targeted condom social marketing campaign in and around areas where female sex workers are present. The paper also describes the method that was used for the routine monitoring of condom availability in these sites. Methods The lot quality assurance sampling (LQAS) method was used for the assessment of the geographical coverage and quality of coverage of condoms in target areas in four states and along selected national highways in India, as part of Avahan, the India AIDS initiative. Results A significant general increase in condom availability was observed in the intervention area between 2005 and 2008. High coverage rates were gradually achieved through an extensive network of pharmacies and particularly of non-traditional outlets, whereas traditional outlets were instrumental in providing large volumes of condoms. Conclusion LQAS is seen as a valuable tool for the routine monitoring of the geographical coverage and of the quality of delivery systems of condoms and of health products and services in general. With a relatively small sample size, easy data collection procedures and simple analytical methods, it was possible to inform decision-makers regularly on progress towards coverage targets. PMID:20167732

  7. Lot quality assurance sampling for monitoring coverage and quality of a targeted condom social marketing programme in traditional and non-traditional outlets in India.

    PubMed

    Piot, Bram; Mukherjee, Amajit; Navin, Deepa; Krishnan, Nattu; Bhardwaj, Ashish; Sharma, Vivek; Marjara, Pritpal

    2010-02-01

    This study reports on the results of a large-scale targeted condom social marketing campaign in and around areas where female sex workers are present. The paper also describes the method that was used for the routine monitoring of condom availability in these sites. The lot quality assurance sampling (LQAS) method was used for the assessment of the geographical coverage and quality of coverage of condoms in target areas in four states and along selected national highways in India, as part of Avahan, the India AIDS initiative. A significant general increase in condom availability was observed in the intervention area between 2005 and 2008. High coverage rates were gradually achieved through an extensive network of pharmacies and particularly of non-traditional outlets, whereas traditional outlets were instrumental in providing large volumes of condoms. LQAS is seen as a valuable tool for the routine monitoring of the geographical coverage and of the quality of delivery systems of condoms and of health products and services in general. With a relatively small sample size, easy data collection procedures and simple analytical methods, it was possible to inform decision-makers regularly on progress towards coverage targets.

  8. Low-dose fixed-target serial synchrotron crystallography.

    PubMed

    Owen, Robin L; Axford, Danny; Sherrell, Darren A; Kuo, Anling; Ernst, Oliver P; Schulz, Eike C; Miller, R J Dwayne; Mueller-Werkmeister, Henrike M

    2017-04-01

    The development of serial crystallography has been driven by the sample requirements imposed by X-ray free-electron lasers. Serial techniques are now being exploited at synchrotrons. Using a fixed-target approach to high-throughput serial sampling, it is demonstrated that high-quality data can be collected from myoglobin crystals, allowing room-temperature, low-dose structure determination. The combination of fixed-target arrays and a fast, accurate translation system allows high-throughput serial data collection at high hit rates and with low sample consumption.

  9. SU-F-J-133: Adaptive Radiation Therapy with a Four-Dimensional Dose Calculation Algorithm That Optimizes Dose Distribution Considering Breathing Motion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ali, I; Algan, O; Ahmad, S

    Purpose: To model patient motion and produce four-dimensional (4D) optimized dose distributions that consider motion-artifacts in the dose calculation during the treatment planning process. Methods: An algorithm for dose calculation is developed where patient motion is considered in dose calculation at the stage of the treatment planning. First, optimal dose distributions are calculated for the stationary target volume where the dose distributions are optimized considering intensity-modulated radiation therapy (IMRT). Second, a convolution-kernel is produced from the best-fitting curve which matches the motion trajectory of the patient. Third, the motion kernel is deconvolved with the initial dose distribution optimized for themore » stationary target to produce a dose distribution that is optimized in four-dimensions. This algorithm is tested with measured doses using a mobile phantom that moves with controlled motion patterns. Results: A motion-optimized dose distribution is obtained from the initial dose distribution of the stationary target by deconvolution with the motion-kernel of the mobile target. This motion-optimized dose distribution is equivalent to that optimized for the stationary target using IMRT. The motion-optimized and measured dose distributions are tested with the gamma index with a passing rate of >95% considering 3% dose-difference and 3mm distance-to-agreement. If the dose delivery per beam takes place over several respiratory cycles, then the spread-out of the dose distributions is only dependent on the motion amplitude and not affected by motion frequency and phase. This algorithm is limited to motion amplitudes that are smaller than the length of the target along the direction of motion. Conclusion: An algorithm is developed to optimize dose in 4D. Besides IMRT that provides optimal dose coverage for a stationary target, it extends dose optimization to 4D considering target motion. This algorithm provides alternative to motion

  10. Beta blockers and chronic heart failure patients: prognostic impact of a dose targeted beta blocker therapy vs. heart rate targeted strategy.

    PubMed

    Corletto, Anna; Fröhlich, Hanna; Täger, Tobias; Hochadel, Matthias; Zahn, Ralf; Kilkowski, Caroline; Winkler, Ralph; Senges, Jochen; Katus, Hugo A; Frankenstein, Lutz

    2018-05-17

    Beta blockers improve survival in patients with chronic systolic heart failure (CHF). Whether physicians should aim for target dose, target heart rate (HR), or both is still under debate. We identified 1,669 patients with systolic CHF due to ischemic heart disease or idiopathic dilated cardiomyopathy from the University Hospital Heidelberg and the Clinic of Ludwigshafen, Germany. All patients were treated with an angiotensin converting enzyme inhibitor or angiotensin receptor blocker and had a history of CHF known for at least 6 months. Target dose was defined as treatment with ≥ 95% of the respective published guideline-recommended dose. Target HR was defined as 51-69 bpm. All-cause mortality during the median follow-up of 42.8 months was analysed with respect to beta blocker dosing and resting HR. 201 (12%) patients met the dose target (group A), 285 (17.1%) met the HR target (group B), 627 (37.6%) met no target (group C), and 556 (33.3%) did not receive beta blockers (Group D). 5-year mortality was 23.7, 22.7, 37.6, and 55.6% for group A, B, C, and D, respectively (p <  0.001). Survival for group A patients with a HR ≥ 70 bpm was 28.8% but 14.8% if HR was 50-70 bpm (p = 0.054). Achieving guidelines recommended beta blocker dose or to HR control has a similar positive impact on survival. When on target dose, supplemental HR control additionally improves survival.

  11. Dosing algorithm to target a predefined AUC in patients with primary central nervous system lymphoma receiving high dose methotrexate.

    PubMed

    Joerger, Markus; Ferreri, Andrés J M; Krähenbühl, Stephan; Schellens, Jan H M; Cerny, Thomas; Zucca, Emanuele; Huitema, Alwin D R

    2012-02-01

    There is no consensus regarding optimal dosing of high dose methotrexate (HDMTX) in patients with primary CNS lymphoma. Our aim was to develop a convenient dosing algorithm to target AUC(MTX) in the range between 1000 and 1100 µmol l(-1) h. A population covariate model from a pooled dataset of 131 patients receiving HDMTX was used to simulate concentration-time curves of 10,000 patients and test the efficacy of a dosing algorithm based on 24 h MTX plasma concentrations to target the prespecified AUC(MTX) . These data simulations included interindividual, interoccasion and residual unidentified variability. Patients received a total of four simulated cycles of HDMTX and adjusted MTX dosages were given for cycles two to four. The dosing algorithm proposes MTX dose adaptations ranging from +75% in patients with MTX C(24) < 0.5 µmol l(-1) up to -35% in patients with MTX C(24) > 12 µmol l(-1). The proposed dosing algorithm resulted in a marked improvement of the proportion of patients within the AUC(MTX) target between 1000 and 1100 µmol l(-1) h (11% with standard MTX dose, 35% with the adjusted dose) and a marked reduction of the interindividual variability of MTX exposure. A simple and practical dosing algorithm for HDMTX has been developed based on MTX 24 h plasma concentrations, and its potential efficacy in improving the proportion of patients within a prespecified target AUC(MTX) and reducing the interindividual variability of MTX exposure has been shown by data simulations. The clinical benefit of this dosing algorithm should be assessed in patients with primary central nervous system lymphoma (PCNSL). © 2011 The Authors. British Journal of Clinical Pharmacology © 2011 The British Pharmacological Society.

  12. Reduction of the unnecessary dose from the over-range area with a spiral dynamic z-collimator: comparison of beam pitch and detector coverage with 128-detector row CT.

    PubMed

    Shirasaka, Takashi; Funama, Yoshinori; Hayashi, Mutsukazu; Awamoto, Shinichi; Kondo, Masatoshi; Nakamura, Yasuhiko; Hatakenaka, Masamitsu; Honda, Hiroshi

    2012-01-01

    Our purpose in this study was to assess the radiation dose reduction and the actual exposed scan length of over-range areas using a spiral dynamic z-collimator at different beam pitches and detector coverage. Using glass rod dosimeters, we measured the unilateral over-range scan dose between the beginning of the planned scan range and the beginning of the actual exposed scan range. Scanning was performed at detector coverage of 80.0 and 40.0 mm, with and without the spiral dynamic z-collimator. The dose-saving ratio was calculated as the ratio of the unnecessary over-range dose, with and without the spiral dynamic z-collimator. In 80.0 mm detector coverage without the spiral dynamic z-collimator, the actual exposed scan length for the over-range area was 108, 120, and 126 mm, corresponding to a beam pitch of 0.60, 0.80, and 0.99, respectively. With the spiral dynamic z-collimator, the actual exposed scan length for the over-range area was 48, 66, and 84 mm with a beam pitch of 0.60, 0.80, and 0.99, respectively. The dose-saving ratios with and without the spiral dynamic z-collimator for a beam pitch of 0.60, 0.80, and 0.99 were 35.07, 24.76, and 13.51%, respectively. With 40.0 mm detector coverage, the dose-saving ratios with and without the spiral dynamic z-collimator had the highest value of 27.23% with a low beam pitch of 0.60. The spiral dynamic z-collimator is important for a reduction in the unnecessary over-range dose and makes it possible to reduce the unnecessary dose by means of a lower beam pitch.

  13. Analytical dose modeling for preclinical proton irradiation of millimetric targets.

    PubMed

    Vanstalle, Marie; Constanzo, Julie; Karakaya, Yusuf; Finck, Christian; Rousseau, Marc; Brasse, David

    2018-01-01

    Due to the considerable development of proton radiotherapy, several proton platforms have emerged to irradiate small animals in order to study the biological effectiveness of proton radiation. A dedicated analytical treatment planning tool was developed in this study to accurately calculate the delivered dose given the specific constraints imposed by the small dimensions of the irradiated areas. The treatment planning system (TPS) developed in this study is based on an analytical formulation of the Bragg peak and uses experimental range values of protons. The method was validated after comparison with experimental data from the literature and then compared to Monte Carlo simulations conducted using Geant4. Three examples of treatment planning, performed with phantoms made of water targets and bone-slab insert, were generated with the analytical formulation and Geant4. Each treatment planning was evaluated using dose-volume histograms and gamma index maps. We demonstrate the value of the analytical function for mouse irradiation, which requires a targeting accuracy of 0.1 mm. Using the appropriate database, the analytical modeling limits the errors caused by misestimating the stopping power. For example, 99% of a 1-mm tumor irradiated with a 24-MeV beam receives the prescribed dose. The analytical dose deviations from the prescribed dose remain within the dose tolerances stated by report 62 of the International Commission on Radiation Units and Measurements for all tested configurations. In addition, the gamma index maps show that the highly constrained targeting accuracy of 0.1 mm for mouse irradiation leads to a significant disagreement between Geant4 and the reference. This simulated treatment planning is nevertheless compatible with a targeting accuracy exceeding 0.2 mm, corresponding to rat and rabbit irradiations. Good dose accuracy for millimetric tumors is achieved with the analytical calculation used in this work. These volume sizes are typical in mouse

  14. Non-targeted effects of ionizing radiation–implications for low dose risk

    PubMed Central

    Kadhim, Munira; Salomaa, Sisko; Wright, Eric; Hildebrandt, Guido; Belyakov, Oleg V.; Prise, Kevin M.; Little, Mark P.

    2014-01-01

    Non-DNA targeted effects of ionizing radiation, which include genomic instability, and a variety of bystander effects including abscopal effects and bystander mediated adaptive response, have raised concerns about the magnitude of low-dose radiation risk. Genomic instability, bystander effects and adaptive responses are powered by fundamental, but not clearly understood systems that maintain tissue homeostasis. Despite excellent research in this field by various groups, there are still gaps in our understanding of the likely mechanisms associated with non-DNA targeted effects, particularly with respect to systemic (human health) consequences at low and intermediate doses of ionizing radiation. Other outstanding questions include links between the different non-targeted responses and the variations in response observed between individuals and cell lines, possibly a function of genetic background. Furthermore, it is still not known what the initial target and early interactions in cells are that give rise to non-targeted responses in neighbouring or descendant cells. This paper provides a commentary on the current state of the field as a result of the Non-targeted effects of ionizing radiation (NOTE) Integrated Project funded by the European Union. Here we critically examine the evidence for non-targeted effects, discuss apparently contradictory results and consider implications for low-dose radiation health effects. PMID:23262375

  15. Immunization coverage among Hispanic ancestry, 2003 National Immunization Survey.

    PubMed

    Darling, Natalie J; Barker, Lawrence E; Shefer, Abigail M; Chu, Susan Y

    2005-12-01

    The Hispanic population is increasing and heterogeneous (Hispanic refers to persons of Spanish, Hispanic, or Latino descent). The objective was to examine immunization rates among Hispanic ancestry for the 4:3:1:3:3 series (> or = 4 doses diphtheria, tetanus toxoids, and pertussis vaccine; > or = 3 doses poliovirus vaccine; > or = 1 doses measles-containing vaccine; > or = 3 doses Haemophilus influenzae type b vaccine; and > or = 3 doses hepatitis B vaccine). The National Immunization Survey measures immunization coverage among 19- to 35-month-old U.S. children. Coverage was compared from combined 2001-2003 data among Hispanics and non-Hispanic whites using t-tests, and among Hispanic ancestry using a chi-square test. Hispanics were categorized as Mexican, Mexican American, Central American, South American, Puerto Rican, Cuban, Spanish Caribbean (primarily Dominican Republic), other, and multiple ancestry. Children of Hispanic ancestry increased from 21% in 1999 to 25% in 2003. These Hispanic children were less well immunized than non-Hispanic whites (77.0%, +/-2.1% [95% confidence interval] compared to 82.5%, +/-1.1% (95% CI) > in 2003). Immunization coverage did not vary significantly among Hispanics of varying ancestries (p=0.26); however, there was substantial geographic variability. In some areas, immunization coverage among Hispanics was significantly higher than non-Hispanic whites. Hispanic children were less well immunized than non-Hispanic whites; however, coverage varied notably by geographic area. Although a chi-square test found no significant differences in coverage among Hispanic ancestries, the range of coverage, 79.2%, +/-5.1% for Cuban Americans to 72.1%, +/-2.4% for Mexican descent, may suggest a need for improved and more localized monitoring among Hispanic communities.

  16. SU-F-J-194: Development of Dose-Based Image Guided Proton Therapy Workflow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pham, R; Sun, B; Zhao, T

    Purpose: To implement image-guided proton therapy (IGPT) based on daily proton dose distribution. Methods: Unlike x-ray therapy, simple alignment based on anatomy cannot ensure proper dose coverage in proton therapy. Anatomy changes along the beam path may lead to underdosing the target, or overdosing the organ-at-risk (OAR). With an in-room mobile computed tomography (CT) system, we are developing a dose-based IGPT software tool that allows patient positioning and treatment adaption based on daily dose distributions. During an IGPT treatment, daily CT images are acquired in treatment position. After initial positioning based on rigid image registration, proton dose distribution is calculatedmore » on daily CT images. The target and OARs are automatically delineated via deformable image registration. Dose distributions are evaluated to decide if repositioning or plan adaptation is necessary in order to achieve proper coverage of the target and sparing of OARs. Besides online dose-based image guidance, the software tool can also map daily treatment doses to the treatment planning CT images for offline adaptive treatment. Results: An in-room helical CT system is commissioned for IGPT purposes. It produces accurate CT numbers that allow proton dose calculation. GPU-based deformable image registration algorithms are developed and evaluated for automatic ROI-delineation and dose mapping. The online and offline IGPT functionalities are evaluated with daily CT images of the proton patients. Conclusion: The online and offline IGPT software tool may improve the safety and quality of proton treatment by allowing dose-based IGPT and adaptive proton treatments. Research is partially supported by Mevion Medical Systems.« less

  17. Measuring populations to improve vaccination coverage

    NASA Astrophysics Data System (ADS)

    Bharti, Nita; Djibo, Ali; Tatem, Andrew J.; Grenfell, Bryan T.; Ferrari, Matthew J.

    2016-10-01

    In low-income settings, vaccination campaigns supplement routine immunization but often fail to achieve coverage goals due to uncertainty about target population size and distribution. Accurate, updated estimates of target populations are rare but critical; short-term fluctuations can greatly impact population size and susceptibility. We use satellite imagery to quantify population fluctuations and the coverage achieved by a measles outbreak response vaccination campaign in urban Niger and compare campaign estimates to measurements from a post-campaign survey. Vaccine coverage was overestimated because the campaign underestimated resident numbers and seasonal migration further increased the target population. We combine satellite-derived measurements of fluctuations in population distribution with high-resolution measles case reports to develop a dynamic model that illustrates the potential improvement in vaccination campaign coverage if planners account for predictable population fluctuations. Satellite imagery can improve retrospective estimates of vaccination campaign impact and future campaign planning by synchronizing interventions with predictable population fluxes.

  18. Measuring populations to improve vaccination coverage

    PubMed Central

    Bharti, Nita; Djibo, Ali; Tatem, Andrew J.; Grenfell, Bryan T.; Ferrari, Matthew J.

    2016-01-01

    In low-income settings, vaccination campaigns supplement routine immunization but often fail to achieve coverage goals due to uncertainty about target population size and distribution. Accurate, updated estimates of target populations are rare but critical; short-term fluctuations can greatly impact population size and susceptibility. We use satellite imagery to quantify population fluctuations and the coverage achieved by a measles outbreak response vaccination campaign in urban Niger and compare campaign estimates to measurements from a post-campaign survey. Vaccine coverage was overestimated because the campaign underestimated resident numbers and seasonal migration further increased the target population. We combine satellite-derived measurements of fluctuations in population distribution with high-resolution measles case reports to develop a dynamic model that illustrates the potential improvement in vaccination campaign coverage if planners account for predictable population fluctuations. Satellite imagery can improve retrospective estimates of vaccination campaign impact and future campaign planning by synchronizing interventions with predictable population fluxes. PMID:27703191

  19. Assessing the universal health coverage target in the Sustainable Development Goals from a human rights perspective.

    PubMed

    Chapman, Audrey R

    2016-12-15

    The UN's Sustainable Development Goals (SDGs), adopted in September 2015, include a comprehensive health goal, "to ensure healthy lives and promote well-being at all ages." The health goal (SDG 3) has nine substantive targets and four additional targets which are identified as a means of implementation. One of these commitments, to achieve universal health coverage (UHC), has been acknowledged as central to the achievement of all of the other health targets. As defined in the SDGs, UHC includes financial risk protection, access to quality essential health-care services, and access to safe, effective, quality and affordable essential medicines and vaccines for all. This article evaluates the extent to which the UHC target in the SDGs conforms with the requirements of the right to health enumerated in the International Covenant on Economic, Social and Cultural Rights, the Convention on the Rights of the Child, and other international human rights instruments and interpreted by international human rights bodies. It does so as a means to identify strengths and weaknesses in the framing of the UHC target that are likely to affect its implementation. While UHC as defined in the SDGs overlaps with human rights standards, there are important human rights omissions that will likely weaken the implementation and reduce the potential benefits of the UHC target. The most important of these is the failure to confer priority to providing access to health services to poor and disadvantaged communities in the process of expanding health coverage and in determining which health services to provide. Unless the furthest behind are given priority and strategies adopted to secure their participation in the development of national health plans, the SDGs, like the MDGs, are likely to leave the most disadvantaged and vulnerable communities behind.

  20. Crude childhood vaccination coverage in West Africa: Trends and predictors of completeness.

    PubMed

    Kazungu, Jacob S; Adetifa, Ifedayo M O

    2017-02-15

    Background : Africa has the lowest childhood vaccination coverage worldwide. If the full benefits of childhood vaccination programmes are to be enjoyed in sub-Saharan Africa, all countries need to improve on vaccine delivery to achieve and sustain high coverage. In this paper, we review trends in vaccination coverage, dropouts between vaccine doses and explored the country-specific predictors of complete vaccination in West Africa.  Methods : We utilized datasets from the Demographic and Health Surveys Program, available for Benin, Burkina Faso, The Gambia, Ghana, Guinea, Cote d'Ivoire, Liberia, Mali, Niger, Nigeria, Senegal, Sierra Leone and Togo, to obtain coverage for Bacillus Calmette-Guerin, polio, measles, and diphtheria, pertussis and tetanus (DPT) vaccines in children aged 12 - 23 months. We also calculated the DPT1-to-DPT3 and DPT1-to-measles dropouts, and proportions of the fully immunised child (FIC). Factors predictive of FIC were explored using Chi-squared tests and multivariable logistic regression.  Results : Overall, there was a trend of increasing vaccination coverage. The proportion of FIC varied significantly by country (range 24.1-81.4%, mean 49%). DPT1-to-DPT3 dropout was high (range 5.1% -33.9%, mean 16.3%). Similarly, DPT1-measles dropout exceeded 10% in all but four countries. Although no single risk factor was consistently associated with FIC across these countries, maternal education, delivery in a health facility, possessing a vaccine card and a recent post delivery visit to a health facility were the key predictors of complete vaccination.  Conclusions : The low numbers of fully immunised children and high dropout between vaccine doses highlights weaknesses and the need to strengthen the healthcare and routine immunization delivery systems in this region. Country-specific correlates of complete vaccination should be explored further to identify interventions required to increase vaccination coverage. Despite the promise of an

  1. Vaccine exemptions and the kindergarten vaccination coverage gap.

    PubMed

    Smith, Philip J; Shaw, Jana; Seither, Ranee; Lopez, Adriana; Hill, Holly A; Underwood, Mike; Knighton, Cynthia; Zhao, Zhen; Ravanam, Megha Shah; Greby, Stacie; Orenstein, Walter A

    2017-09-25

    Vaccination requirements for kindergarten entry vary by state, but all states require 2 doses of measles containing vaccine (MCV) at kindergarten entry. To assess (i) national MCV vaccination coverage for children who had attended kindergarten; (ii) the extent to which undervaccination after kindergarten entry is attributable to parents' requests for an exemption; (iii) the extent to which undervaccinated children had missed opportunities to be administered missing vaccine doses among children whose parent did not request an exemption; and (iv) the vaccination coverage gap between the "highest achievable" MCV coverage and actual MCV coverage among children who had attended kindergarten. A national survey of 1465 parents of 5-7year-old children was conducted during October 2013 through March 2014. Vaccination coverage estimates are based provider-reported vaccination histories. Children have a "missed opportunity" for MCV if they were not up-to-date and if there were dates on which other vaccines were administered but not MCV. The "highest achievable" MCV vaccination coverage rate is 100% minus the sum of the percentages of (i) undervaccinated children with parents who requested an exemption; and (ii) undervaccinated children with parents who did not request an exemption and whose vaccination statuses were assessed during a kindergarten grace period or period when they were provisionally enrolled in kindergarten. Among all children undervaccinated for MCV, 2.7% were attributable to having a parent who requested an exemption. Among children who were undervaccinated for MCV and whose parent did not request an exemption, 41.6% had a missed opportunity for MCV. The highest achievable MCV coverage was 98.6%, actual MCV coverage was 90.9%, and the kindergarten vaccination gap was 7.7%. Vaccination coverage may be increased by schools fully implementing state kindergarten vaccination laws, and by providers assessing children's vaccination status at every clinic visit, and

  2. In vivo tumor targeting of gold nanoparticles: effect of particle type and dosing strategy.

    PubMed

    Puvanakrishnan, Priyaveena; Park, Jaesook; Chatterjee, Deyali; Krishnan, Sunil; Tunnell, James W

    2012-01-01

    Gold nanoparticles (GNPs) have gained significant interest as nanovectors for combined imaging and photothermal therapy of tumors. Delivered systemically, GNPs preferentially accumulate at the tumor site via the enhanced permeability and retention effect, and when irradiated with near infrared light, produce sufficient heat to treat tumor tissue. The efficacy of this process strongly depends on the targeting ability of the GNPs, which is a function of the particle's geometric properties (eg, size) and dosing strategy (eg, number and amount of injections). The purpose of this study was to investigate the effect of GNP type and dosing strategy on in vivo tumor targeting. Specifically, we investigated the in vivo tumor-targeting efficiency of pegylated gold nanoshells (GNSs) and gold nanorods (GNRs) for single and multiple dosing. We used Swiss nu/nu mice with a subcutaneous tumor xenograft model that received intravenous administration for a single and multiple doses of GNS and GNR. We performed neutron activation analysis to quantify the gold present in the tumor and liver. We performed histology to determine if there was acute toxicity as a result of multiple dosing. Neutron activation analysis results showed that the smaller GNRs accumulated in higher concentrations in the tumor compared to the larger GNSs. We observed a significant increase in GNS and GNR accumulation in the liver for higher doses. However, multiple doses increased targeting efficiency with minimal effect beyond three doses of GNPs. These results suggest a significant effect of particle type and multiple doses on increasing particle accumulation and on tumor targeting ability.

  3. Universal field matching in craniospinal irradiation by a background-dose gradient-optimized method.

    PubMed

    Traneus, Erik; Bizzocchi, Nicola; Fellin, Francesco; Rombi, Barbara; Farace, Paolo

    2018-01-01

    The gradient-optimized methods are overcoming the traditional feathering methods to plan field junctions in craniospinal irradiation. In this note, a new gradient-optimized technique, based on the use of a background dose, is described. Treatment planning was performed by RayStation (RaySearch Laboratories, Stockholm, Sweden) on the CT scans of a pediatric patient. Both proton (by pencil beam scanning) and photon (by volumetric modulated arc therapy) treatments were planned with three isocenters. An 'in silico' ideal background dose was created first to cover the upper-spinal target and to produce a perfect dose gradient along the upper and lower junction regions. Using it as background, the cranial and the lower-spinal beams were planned by inverse optimization to obtain dose coverage of their relevant targets and of the junction volumes. Finally, the upper-spinal beam was inversely planned after removal of the background dose and with the previously optimized beams switched on. In both proton and photon plans, the optimized cranial and the lower-spinal beams produced a perfect linear gradient in the junction regions, complementary to that produced by the optimized upper-spinal beam. The final dose distributions showed a homogeneous coverage of the targets. Our simple technique allowed to obtain high-quality gradients in the junction region. Such technique universally works for photons as well as protons and could be applicable to the TPSs that allow to manage a background dose. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  4. Intensity modulated radiation therapy (IMRT): differences in target volumes and improvement in clinically relevant doses to small bowel in rectal carcinoma.

    PubMed

    Mok, Henry; Crane, Christopher H; Palmer, Matthew B; Briere, Tina M; Beddar, Sam; Delclos, Marc E; Krishnan, Sunil; Das, Prajnan

    2011-06-08

    , without incurring penalty with respect to adjacent organs-at-risk. For rectal carcinoma, IMRT, compared to 3DCRT, yielded plans superior with respect to target coverage, homogeneity, and conformality, while lowering dose to adjacent organs-at-risk. This is achieved despite treating larger volumes, raising the possibility of a clinically-relevant improvement in the therapeutic ratio through the use of IMRT with a belly-board apparatus.

  5. Coverage That Counts.

    ERIC Educational Resources Information Center

    Moss, Nancy

    1990-01-01

    As the shrinking pool of applicants forces colleges to adapt new approaches to recruiting, media campaigns are emerging as an effective way to send key messages to target audiences. Media relations can lend credibility (news coverage is considered more credible than advertising); save money; reach targeted areas; and communicate key themes. (MLW)

  6. Immunisation coverage annual report, 2011.

    PubMed

    Hull, Brynley P; Dey, Aditi; Menzies, Rob I; Brotherton, Julia M; McIntyre, Peter B

    2013-12-31

    This, the 5th annual immunisation coverage report, documents trends during 2011 for a range of standard measures derived from Australian Childhood Immunisation Register data, and National Human Papillomavirus (HPV) Vaccination Program Register data. The proportion of children 'fully vaccinated' at 12, 24 and 60 months of age was 91.4%, 92.2% and 89.5% respectively. Although pneumococcal vaccine had similar coverage at 12 months to other vaccines, coverage was lower for rotavirus at 12 months (83.8%) and varicella at 24 months (83.9%). By late 2011, the percentage of children who received the 1st dose of DTPa vaccine dose at less than 8 weeks of age was greater than 50% in 3 jurisdictions, the Australian Capital Territory, Victoria, and Queensland and at 70% for New South Wales and Tasmania. Although coverage at 12 months of age was lower among Indigenous children than non-Indigenous children in all jurisdictions, the extent of the difference varied. Overall, coverage at 24 months of age exceeded that at 12 months of age nationally. At 60 months of age, there was dramatic variation between individual jurisdictions, ranging from coverage 8% lower in Indigenous children in South Australia to 6% higher in the Northern Territory. As previously documented, vaccines recommended for Indigenous children only (hepatitis A and pneumococcal polysaccharide vaccine) had suboptimal coverage at 60% and 68%, respectively. On-time receipt (before 49 months of age) of vaccines by Indigenous children at the 60-month milestone age improved between 2010 (18%) and 2011 (19%) but the disparity in on-time vaccination between Indigenous and non-Indigenous children increased at all 3 age milestones. The percentage of vaccine objectors in 2011 (1.7%) has increased from 2007 when it was 1.1%. Coverage data for the 3rd dose of HPV from the national HPV register in the school catch up program was 71% but was substantially lower for the catch-up program for women outside school (39

  7. Critical target and dose and dose-rate responses for the induction of chromosomal instability by ionizing radiation

    NASA Technical Reports Server (NTRS)

    Limoli, C. L.; Corcoran, J. J.; Milligan, J. R.; Ward, J. F.; Morgan, W. F.

    1999-01-01

    To investigate the critical target, dose response and dose-rate response for the induction of chromosomal instability by ionizing radiation, bromodeoxyuridine (BrdU)-substituted and unsubstituted GM10115 cells were exposed to a range of doses (0.1-10 Gy) and different dose rates (0.092-17.45 Gy min(-1)). The status of chromosomal stability was determined by fluorescence in situ hybridization approximately 20 generations after irradiation in clonal populations derived from single progenitor cells surviving acute exposure. Overall, nearly 700 individual clones representing over 140,000 metaphases were analyzed. In cells unsubstituted with BrdU, a dose response was found, where the probability of observing delayed chromosomal instability in any given clone was 3% per gray of X rays. For cells substituted with 25-66% BrdU, however, a dose response was observed only at low doses (<1.0 Gy); at higher doses (>1.0 Gy), the incidence of chromosomal instability leveled off. There was an increase in the frequency and complexity of chromosomal instability per unit dose compared to cells unsubstituted with BrdU. The frequency of chromosomal instability appeared to saturate around approximately 30%, an effect which occurred at much lower doses in the presence of BrdU. Changing the gamma-ray dose rate by a factor of 190 (0.092 to 17.45 Gy min(-1)) produced no significant differences in the frequency of chromosomal instability. The enhancement of chromosomal instability promoted by the presence of the BrdU argues that DNA comprises at least one of the critical targets important for the induction of this end point of genomic instability.

  8. Molybdenum target specifications for cyclotron production of 99mTc based on patient dose estimates.

    PubMed

    Hou, X; Tanguay, J; Buckley, K; Schaffer, P; Bénard, F; Ruth, T J; Celler, A

    2016-01-21

    In response to the recognized fragility of reactor-produced (99)Mo supply, direct production of (99m)Tc via (100)Mo(p,2n)(99m)Tc reaction using medical cyclotrons has been investigated. However, due to the existence of other Molybdenum (Mo) isotopes in the target, in parallel with (99m)Tc, other technetium (Tc) radioactive isotopes (impurities) will be produced. They will be incorporated into the labeled radiopharmaceuticals and result in increased patient dose. The isotopic composition of the target and beam energy are main factors that determine production of impurities, thus also dose increases. Therefore, they both must be considered when selecting targets for clinical (99m)Tc production. Although for any given Mo target, the patient dose can be predicted based on complicated calculations of production yields for each Tc radioisotope, it would be very difficult to reverse these calculations to specify target composition based on dosimetry considerations. In this article, a relationship between patient dosimetry and Mo target composition is studied. A simple and easy algorithm for dose estimation, based solely on the knowledge of target composition and beam energy, is described. Using this algorithm, the patient dose increase due to every Mo isotope that could be present in the target is estimated. Most importantly, a technique to determine Mo target composition thresholds that would meet any given dosimetry requirement is proposed.

  9. Molybdenum target specifications for cyclotron production of 99mTc based on patient dose estimates

    NASA Astrophysics Data System (ADS)

    Hou, X.; Tanguay, J.; Buckley, K.; Schaffer, P.; Bénard, F.; Ruth, T. J.; Celler, A.

    2016-01-01

    In response to the recognized fragility of reactor-produced 99Mo supply, direct production of 99mTc via 100Mo(p,2n)99mTc reaction using medical cyclotrons has been investigated. However, due to the existence of other Molybdenum (Mo) isotopes in the target, in parallel with 99mTc, other technetium (Tc) radioactive isotopes (impurities) will be produced. They will be incorporated into the labeled radiopharmaceuticals and result in increased patient dose. The isotopic composition of the target and beam energy are main factors that determine production of impurities, thus also dose increases. Therefore, they both must be considered when selecting targets for clinical 99mTc production. Although for any given Mo target, the patient dose can be predicted based on complicated calculations of production yields for each Tc radioisotope, it would be very difficult to reverse these calculations to specify target composition based on dosimetry considerations. In this article, a relationship between patient dosimetry and Mo target composition is studied. A simple and easy algorithm for dose estimation, based solely on the knowledge of target composition and beam energy, is described. Using this algorithm, the patient dose increase due to every Mo isotope that could be present in the target is estimated. Most importantly, a technique to determine Mo target composition thresholds that would meet any given dosimetry requirement is proposed.

  10. Evaluation of Dose Uncertainty to the Target Associated With Real-Time Tracking Intensity-Modulated Radiation Therapy Using the CyberKnife Synchrony System.

    PubMed

    Iwata, Hiromitsu; Inoue, Mitsuhiro; Shiomi, Hiroya; Murai, Taro; Tatewaki, Koshi; Ohta, Seiji; Okawa, Kohei; Yokota, Naoki; Shibamoto, Yuta

    2016-02-01

    We investigated the dose uncertainty caused by errors in real-time tracking intensity-modulated radiation therapy (IMRT) using the CyberKnife Synchrony Respiratory Tracking System (SRTS). Twenty lung tumors that had been treated with non-IMRT real-time tracking using CyberKnife SRTS were used for this study. After validating the tracking error in each case, we did 40 IMRT planning using 8 different collimator sizes for the 20 patients. The collimator size was determined for each planning target volume (PTV); smaller ones were one-half, and larger ones three-quarters, of the PTV diameter. The planned dose was 45 Gy in 4 fractions prescribed at 95% volume border of the PTV. Thereafter, the tracking error in each case was substituted into calculation software developed in house and randomly added in the setting of each beam. The IMRT planning incorporating tracking errors was simulated 1000 times, and various dose data on the clinical target volume (CTV) were compared with the original data. The same simulation was carried out by changing the fraction number from 1 to 6 in each IMRT plan. Finally, a total of 240 000 plans were analyzed. With 4 fractions, the change in the CTV maximum and minimum doses was within 3.0% (median) for each collimator. The change in D99 and D95 was within 2.0%. With decreases in the fraction number, the CTV coverage rate and the minimum dose decreased and varied greatly. The accuracy of real-time tracking IMRT delivered in 4 fractions using CyberKnife SRTS was considered to be clinically acceptable. © The Author(s) 2014.

  11. Multi-axis dose accumulation of noninvasive image-guided breast brachytherapy through biomechanical modeling of tissue deformation using the finite element method

    PubMed Central

    Ghadyani, Hamid R.; Bastien, Adam D.; Lutz, Nicholas N.; Hepel, Jaroslaw T.

    2015-01-01

    Purpose Noninvasive image-guided breast brachytherapy delivers conformal HDR 192Ir brachytherapy treatments with the breast compressed, and treated in the cranial-caudal and medial-lateral directions. This technique subjects breast tissue to extreme deformations not observed for other disease sites. Given that, commercially-available software for deformable image registration cannot accurately co-register image sets obtained in these two states, a finite element analysis based on a biomechanical model was developed to deform dose distributions for each compression circumstance for dose summation. Material and methods The model assumed the breast was under planar stress with values of 30 kPa for Young's modulus and 0.3 for Poisson's ratio. Dose distributions from round and skin-dose optimized applicators in cranial-caudal and medial-lateral compressions were deformed using 0.1 cm planar resolution. Dose distributions, skin doses, and dose-volume histograms were generated. Results were examined as a function of breast thickness, applicator size, target size, and offset distance from the center. Results Over the range of examined thicknesses, target size increased several millimeters as compression thickness decreased. This trend increased with increasing offset distances. Applicator size minimally affected target coverage, until applicator size was less than the compressed target size. In all cases, with an applicator larger or equal to the compressed target size, > 90% of the target covered by > 90% of the prescription dose. In all cases, dose coverage became less uniform as offset distance increased and average dose increased. This effect was more pronounced for smaller target–applicator combinations. Conclusions The model exhibited skin dose trends that matched MC-generated benchmarking results within 2% and clinical observations over a similar range of breast thicknesses and target sizes. The model provided quantitative insight on dosimetric treatment variables

  12. Seasonal influenza vaccine coverage among high-risk populations in Thailand, 2010-2012.

    PubMed

    Owusu, Jocelynn T; Prapasiri, Prabda; Ditsungnoen, Darunee; Leetongin, Grit; Yoocharoen, Pornsak; Rattanayot, Jarowee; Olsen, Sonja J; Muangchana, Charung

    2015-01-29

    The Advisory Committee on Immunization Practice of Thailand prioritizes seasonal influenza vaccinations for populations who are at highest risk for serious complications (pregnant women, children 6 months-2 years, persons ≥65 years, persons with chronic diseases, obese persons), and healthcare personnel and poultry cullers. The Thailand government purchases seasonal influenza vaccine for these groups. We assessed vaccination coverage among high-risk groups in Thailand from 2010 to 2012. National records on persons who received publicly purchased vaccines from 2010 to 2012 were analyzed by high-risk category. Denominator data from multiple sources were compared to calculate coverage. Vaccine coverage was defined as the proportion of individuals in each category who received the vaccine. Vaccine wastage was defined as the proportion of publicly purchased vaccines that were not used. From 2010 to 2012, 8.18 million influenza vaccines were publicly purchased (range, 2.37-3.29 million doses/year), and vaccine purchases increased 39% over these years. Vaccine wastage was 9.5%. Approximately 5.7 million (77%) vaccine doses were administered to persons ≥65 years and persons with chronic diseases, 1.4 million (19%) to healthcare personnel/poultry cullers, 82,570 (1.1%) to children 6 months-2 years, 78,885 (1.1%) to obese persons, 26,481 (0.4%) to mentally disabled persons, and 17,787 (0.2%) to pregnant women. Between 2010 and 2012, coverage increased among persons with chronic diseases (8.6% versus 14%; p<0.01) and persons ≥65 years (12%, versus 20%; p<0.01); however, coverage decreased for mentally disabled persons (6.1% versus 4.9%; p<0.01), children 6 months-2 years (2.3% versus 0.9%; p<0.01), pregnant women (1.1% versus 0.9%; p<0.01), and obese persons (0.2% versus 0.1%; p<0.01). From 2010 to 2012, the availability of publicly purchased vaccines increased. While coverage remained low for all target groups, coverage was highest among persons ≥65 years and persons

  13. Quantifying the impact of immediate reconstruction in postmastectomy radiation: a large, dose-volume histogram-based analysis.

    PubMed

    Ohri, Nisha; Cordeiro, Peter G; Keam, Jennifer; Ballangrud, Ase; Shi, Weiji; Zhang, Zhigang; Nerbun, Claire T; Woch, Katherine M; Stein, Nicholas F; Zhou, Ying; McCormick, Beryl; Powell, Simon N; Ho, Alice Y

    2012-10-01

    To assess the impact of immediate breast reconstruction on postmastectomy radiation (PMRT) using dose-volume histogram (DVH) data. Two hundred forty-seven women underwent PMRT at our center, 196 with implant reconstruction and 51 without reconstruction. Patients with reconstruction were treated with tangential photons, and patients without reconstruction were treated with en-face electron fields and customized bolus. Twenty percent of patients received internal mammary node (IMN) treatment. The DVH data were compared between groups. Ipsilateral lung parameters included V20 (% volume receiving 20 Gy), V40 (% volume receiving 40 Gy), mean dose, and maximum dose. Heart parameters included V25 (% volume receiving 25 Gy), mean dose, and maximum dose. IMN coverage was assessed when applicable. Chest wall coverage was assessed in patients with reconstruction. Propensity-matched analysis adjusted for potential confounders of laterality and IMN treatment. Reconstruction was associated with lower lung V20, mean dose, and maximum dose compared with no reconstruction (all P<.0001). These associations persisted on propensity-matched analysis (all P<.0001). Heart doses were similar between groups (P=NS). Ninety percent of patients with reconstruction had excellent chest wall coverage (D95 >98%). IMN coverage was superior in patients with reconstruction (D95 >92.0 vs 75.7%, P<.001). IMN treatment significantly increased lung and heart parameters in patients with reconstruction (all P<.05) but minimally affected those without reconstruction (all P>.05). Among IMN-treated patients, only lower lung V20 in those without reconstruction persisted (P=.022), and mean and maximum heart doses were higher than in patients without reconstruction (P=.006, P=.015, respectively). Implant reconstruction does not compromise the technical quality of PMRT when the IMNs are untreated. Treatment technique, not reconstruction, is the primary determinant of target coverage and normal tissue doses

  14. Correlation between measles vaccine doses: implications for the maintenance of elimination.

    PubMed

    McKee, A; Ferrari, M J; Shea, K

    2018-03-01

    Measles eradication efforts have been successful at achieving elimination in many countries worldwide. Such countries actively work to maintain this elimination by continuing to improve coverage of two routine doses of measles vaccine following measles elimination. While improving measles vaccine coverage is always beneficial, we show, using a steady-state analysis of a dynamical model, that the correlation between populations receiving the first and second routine dose also has a significant impact on the population immunity achieved by a specified combination of first and second dose coverage. If the second dose is administered to people independently of whether they had the first dose, high second-dose coverage improves the proportion of the population receiving at least one dose, and will have a large effect on population immunity. If the second dose is administered only to people who have had the first dose, high second-dose coverage reduces the rate of primary vaccine failure, but does not reach people who missed the first dose; this will therefore have a relatively small effect on population immunity. When doses are administered dependently, and assuming the first dose has higher coverage, increasing the coverage of the first dose has a larger impact on population immunity than does increasing the coverage of the second. Correlation between vaccine doses has a significant impact on the level of population immunity maintained by current vaccination coverage, potentially outweighing the effects of age structure and, in some cases, recent improvements in vaccine coverage. It is therefore important to understand the correlation between vaccine doses as such correlation may have a large impact on the effectiveness of measles vaccination strategies.

  15. Dose response of bone-targeted enzyme replacement for murine hypophosphatasia.

    PubMed

    Yadav, Manisha C; Lemire, Isabelle; Leonard, Pierre; Boileau, Guy; Blond, Laurent; Beliveau, Martin; Cory, Esther; Sah, Robert L; Whyte, Michael P; Crine, Philippe; Millán, José Luis

    2011-08-01

    Hypophosphatasia (HPP) features rickets or osteomalacia from tissue-nonspecific alkaline phosphatase (TNSALP) deficiency due to deactivating mutations within the ALPL gene. Enzyme replacement therapy with a bone-targeted, recombinant TNSALP (sALP-FcD(10), renamed ENB-0040) prevents manifestations of HPP when initiated at birth in TNSALP knockout (Akp2(-/-)) mice. Here, we evaluated the dose-response relationship of ENB-0040 to various phenotypic traits of Akp2(-/-) mice receiving daily subcutaneous (SC) injections of ENB-0040 from birth at 0.5, 2.0, or 8.2mg/kg for 43days. Radiographs, μCT, and histomorphometric analyses documented better bone mineralization with increasing doses of ENB-0040. We found a clear, positive correlation between ENB-0040 dose and prevention of mineralization defects of the feet, rib cage, lower limbs, and jaw bones. According to a dose-response model, the ED(80) (the dose that prevents bone defects in 80% of mice) was 3.2, 2.8 and 2.9mg/kg/day for these sites, respectively. Long bones seemed to respond to lower daily doses of ENB-0040. There was also a positive relationship between ENB-0040 dose and survival. Median survival, body weight, and bone length all improved with increasing doses of ENB-0040. Urinary PP(i) concentrations remained elevated in all treatment groups, indicating that while this parameter is a good biochemical marker for diagnosing HPP in patients, it may not be a good follow up marker for evaluating response to treatment when administering bone-targeted TNSALP to mice. These dose-response relationships strongly support the pharmacological efficacy of ENB-0040 for HPP, and provide the experimental basis for the therapeutic range of ENB-0040 chosen for clinical trials. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Dose response of bone-targeted enzyme replacement for murine hypophosphatasia

    PubMed Central

    Yadav, Manisha C.; Lemire, Isabelle; Leonard, Pierre; Boileau, Guy; Blond, Laurent; Beliveau, Martin; Cory, Esther; Sah, Robert L.; Whyte, Michael P.; Crine, Philippe; Millán, José Luis

    2011-01-01

    Hypophosphatasia (HPP) features rickets or osteomalacia from tissue-nonspecific alkaline phosphatase (TNSALP) deficiency due to deactivating mutations within the ALPL gene. Enzyme replacement therapy with a bone-targeted, recombinant TNSALP (sALP-FcD10, renamed ENB-0040) prevents manifestations of HPP when initiated at birth in TNSALP knockout (Akp2−/−) mice. Here, we evaluated the dose-response relationship of ENB-0040 to various phenotypic traits of Akp2−/− mice receiving daily subcutaneous (SC) injections of ENB-0040 from birth at 0.5, 2.0, or 8.2 mg/kg for 43 days. Radiographs, μCT, and histomorphometric analyses documented better bone mineralization with increasing doses of ENB-0040. We found a clear, positive correlation between ENB-0040 dose and prevention of mineralization defects of the feet, rib cage, lower limbs, and jaw bones. According to a dose-response model, the ED80 (the dose prevents the bone defects in 80% of mice) was 3.2, 2.8 and 2.9 mg/kg/day for these sites, respectively. Long bones seemed to respond to lower daily doses of ENB-0040. There was also a positive relationship between ENB-0040 dose and survival. Median survival, body weight, and bone length all improved with increasing doses of ENB-0040. Urinary PPi concentrations remained elevated in all treatment groups, indicating that while this parameter is a good biochemical marker for diagnosing HPP, it may not be a good follow up marker for evaluating response to treatment when administering bone-targeted TNSALP. These dose-response relationships strongly support the pharmacological efficacy of ENB-0040 for HPP, and provide the experimental basis for the therapeutic range of ENB-0040 chosen for clinical trials. PMID:21458605

  17. Dosimetric comparison of IMRT rectal and anal canal plans generated using an anterior dose avoidance structure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leicher, Brian, E-mail: bleicher@wpahs.org; Day, Ellen; Colonias, Athanasios

    2014-10-01

    To describe a dosimetric method using an anterior dose avoidance structure (ADAS) during the treatment planning process for intensity-modulated radiation therapy (IMRT) for patients with anal canal and rectal carcinomas. A total of 20 patients were planned on the Elekta/CMS XiO treatment planning system, version 4.5.1 (Maryland Heights MO) with a superposition algorithm. For each patient, 2 plans were created: one employing an ADAS (ADAS plan) and the other replanned without an ADAS (non-ADAS plan). The ADAS was defined to occupy the volume between the inguinal nodes and primary target providing a single organ at risk that is completely outsidemore » of the target volume. Each plan used the same beam parameters and was analyzed by comparing target coverage, overall plan dose conformity using a conformity number (CN) equation, bowel dose-volume histograms, and the number of segments, daily treatment duration, and global maximum dose. The ADAS and non-ADAS plans were equivalent in target coverage, mean global maximum dose, and sparing of small bowel in low-dose regions (5, 10, 15, and 20 Gy). The mean difference between the CN value for the non-ADAS plans and ADAS plans was 0.04 ± 0.03 (p < 0.001). The mean difference in the number of segments was 15.7 ± 12.7 (p < 0.001) in favor of ADAS plans. The ADAS plan delivery time was shorter by 2.0 ± 1.5 minutes (p < 0.001) than the non-ADAS one. The ADAS has proven to be a powerful tool when planning rectal and anal canal IMRT cases with critical structures partially contained inside the target volume.« less

  18. Vitamin A-first dose supplement coverage evaluation amongst children aged 12–23 months residing in slums of Delhi, India

    PubMed Central

    Sachdeva, Sandeep; Datta, Utsuk

    2009-01-01

    Objective: To determine vitamin A-first dose supplement coverage in children aged 12–23 months and to find out its correlates with selected variables. Materials and Methods: The 30-cluster sampling technique based on probability proportional to size advocated by the World Health Organization was used to assess vitamin A-first dose supplement amongst 210 children in the age group of 12–23 months residing in slums of a randomly selected municipal zone of Delhi during October to November 2005. Results: Only 79 (37.6%) children out of 210 had received vitamin A-first dose supplement. Further analysis of 79 children was carried out with regard to selected variables like religion, gender, birth order, place of birth, immunization status and literacy of mother. These analyses showed that 71 (89.9%) were Hindu and eight (10.1%) were non-Hindu (P = 0.04). Nearly 44 (55.7%) males and 35 (44.3%) females had received vitamin A (P = 0.74). The proportion of children born in a health institution who received first dose (57%) of vitamin A supplementation was significantly higher than of those who were born at home (43%) (P < 0.001). Similarly, higher proportion of children with birth order-one (48.1%) in comparison to birth order-three or above (26.6%) received vitamin A (P < 0.001). Thirty children though fully immunized for vaccine-preventable disease up to the age-of-one year had not received vitamin A-first dose supplement, suggesting that an opportunity had been missed. The association between receipt of vitamin A by the child and literacy status of mother was found to be significant (P < 0.001). Conclusion: The study reflects low coverage of Vitamin A supplement. PMID:19574699

  19. [EEG-adjusted target-controlled infusion : Propofol target concentration with different doses of remifentanil].

    PubMed

    Büttner, N; Schultz, B; Grouven, U; Schultz, A

    2010-02-01

    The aim of this study was to examine to what extent the use of electroencephalography (EEG) monitoring leads to an adaptation of the target-controlled infusion (TCI) concentration of propofol during propofol anaesthesia with different doses of remifentanil. With ethics committee approval 60 patients (27-69 years old) with American Society of Anesthesiologists classification (ASA) I-III received anaesthestics with propofol (TCI, Diprifusor, AstraZeneca, Wedel, Deutschland) and 0.2, 0.4, or 0.6 microg/kg body weight remifentanil, respectively (groups 1-3). Anaesthesia was maintained at a level of deep hypnosis (EEG stages D(2)/E(0), EEG monitor: Narcotrend, version 2.0/5.0, manufacturer: MT MonitorTechnik, Bad Bramstedt, Germany). During the steady state the propofol concentration in groups 1-3 was 3.02+/-0.86, 1.93+/-0.53 and 1.60+/-0.55 microg/ml, respectively (p<0.001). Women had a higher propofol consumption than men (p<0.05). Dreams during anaesthesia were more often reported by women than by men (p<0.05). The need for postoperative analgesia decreased with an increasing intraoperative remifentanil dose (p<0.05). The study demonstrates that remifentanil has both analgetic and hypnotic effects. With increasing remifentanil dose the propofol requirement decreased and in this context EEG monitoring is useful to adapt the target concentrations of propofol to the patients' age and gender.

  20. [Media coverage of suicide: From the epidemiological observations to prevention avenues].

    PubMed

    Notredame, Charles-Édouard; Pauwels, Nathalie; Walter, Michel; Danel, Thierry; Vaiva, Guillaume

    2015-12-01

    Media coverage of suicide can result in increased morbi-mortality suicidal rates, due to an imitation process in those who are particularly vulnerable. This phenomenon is known as "Werther effect". Werther effect's magnitude depends on several qualitative and quantitative characteristics of the media coverage, in a dose-effect relationship. An extensive (in terms of audience and history repetition) and salient coverage (glorification of suicide, description of the suicidal method, etc.) increases the risk of contagion. Celebrities' suicide is particularly at risk of Werther effect. Media may also have a preventive role with respect to suicide. Indeed, according to "Papageno effect", journalists could, under certain conditions, help preventing suicide when reporting suicide stories. Two main theories in the field of social psychology have been proposed to account for Werther and Papageno effects: social learning theory and differential identification. Identification of Werther and Papageno effects uncovers new responsibilities and potentialities for the journalists in terms of public health. Their description provides a basis for promising targeted prevention actions. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  1. Interactive dose shaping part 2: proof of concept study for six prostate patients

    NASA Astrophysics Data System (ADS)

    Kamerling, Cornelis Ph; Ziegenhein, Peter; Sterzing, Florian; Oelfke, Uwe

    2016-03-01

    Recently we introduced interactive dose shaping (IDS) as a new IMRT planning strategy. This planning concept is based on a hierarchical sequence of local dose modification and recovery operations. The purpose of this work is to provide a feasibility study for the IDS planning strategy based on a small set of six prostate patients. The IDS planning paradigm aims to perform interactive local dose adaptations of an IMRT plan without compromising already established valuable dose features in real-time. Various IDS tools were developed in our in-house treatment planning software Dynaplan and were utilized to create IMRT treatment plans for six patients with an adeno-carcinoma of the prostate. The sequenced IDS treatment plans were compared to conventionally optimized clinically approved plans (9 beams, co-planar). For each patient, several IDS plans were created, with different trade-offs between organ sparing and target coverage. The reference dose distributions were imported into Dynaplan. For each patient, the IDS treatment plan with a similar or better trade-off between target coverage and OAR sparing was selected for plan evaluation, guided by a physician. For this initial study we were able to generate treatment plans for prostate geometries in 15-45 min. Individual local dose adaptations could be performed in less than one second. The average differences compared to the reference plans were for the mean dose: 0.0 Gy (boost) and 1.2 Gy (PTV), for {{D}98%}:-1.1 Gy and for {{D}2%}:1.1 Gy (both target volumes). The dose-volume quality indicators were well below the Quantec constraints. However, we also observed limitations of our currently implemented approach. Most prominent was an increase of the non-tumor integral dose by 16.4% on average, demonstrating that further developments of our planning strategy are required.

  2. Experimentally studied dynamic dose interplay does not meaningfully affect target dose in VMAT SBRT lung treatments.

    PubMed

    Stambaugh, Cassandra; Nelms, Benjamin E; Dilling, Thomas; Stevens, Craig; Latifi, Kujtim; Zhang, Geoffrey; Moros, Eduardo; Feygelman, Vladimir

    2013-09-01

    The effects of respiratory motion on the tumor dose can be divided into the gradient and interplay effects. While the interplay effect is likely to average out over a large number of fractions, it may play a role in hypofractionated [stereotactic body radiation therapy (SBRT)] treatments. This subject has been extensively studied for intensity modulated radiation therapy but less so for volumetric modulated arc therapy (VMAT), particularly in application to hypofractionated regimens. Also, no experimental study has provided full four-dimensional (4D) dose reconstruction in this scenario. The authors demonstrate how a recently described motion perturbation method, with full 4D dose reconstruction, is applied to describe the gradient and interplay effects during VMAT lung SBRT treatments. VMAT dose delivered to a moving target in a patient can be reconstructed by applying perturbations to the treatment planning system-calculated static 3D dose. Ten SBRT patients treated with 6 MV VMAT beams in five fractions were selected. The target motion (motion kernel) was approximated by 3D rigid body translation, with the tumor centroids defined on the ten phases of the 4DCT. The motion was assumed to be periodic, with the period T being an average from the empirical 4DCT respiratory trace. The real observed tumor motion (total displacement ≤ 8 mm) was evaluated first. Then, the motion range was artificially increased to 2 or 3 cm. Finally, T was increased to 60 s. While not realistic, making T comparable to the delivery time elucidates if the interplay effect can be observed. For a single fraction, the authors quantified the interplay effect as the maximum difference in the target dosimetric indices, most importantly the near-minimum dose (D99%), between all possible starting phases. For the three- and five-fractions, statistical simulations were performed when substantial interplay was found. For the motion amplitudes and periods obtained from the 4DCT, the interplay effect

  3. How much does it cost to achieve coverage targets for primary healthcare services? A costing model from Aceh, Indonesia.

    PubMed

    Abdullah, Asnawi; Hort, Krishna; Abidin, Azwar Zaenal; Amin, Fadilah M

    2012-01-01

    Despite significant investment in improving service infrastructure and training of staff, public primary healthcare services in low-income and middle-income countries tend to perform poorly in reaching coverage targets. One of the factors identified in Aceh, Indonesia was the lack of operational funds for service provision. The objective of this study was to develop a simple and transparent costing tool that enables health planners to calculate the unit costs of providing basic health services to estimate additional budgets required to deliver services in accordance with national targets. The tool was developed using a standard economic approach that linked the input activities to achieving six national priority programs at primary healthcare level: health promotion, sanitation and environment health, maternal and child health and family planning, nutrition, immunization and communicable diseases control, and treatment of common illness. Costing was focused on costs of delivery of the programs that need to be funded by local government budgets. The costing tool consisting of 16 linked Microsoft Excel worksheets was developed and tested in several districts enabled the calculation of the unit costs of delivering of the six national priority programs per coverage target of each program (such as unit costs of delivering of maternal and child health program per pregnant mother). This costing tool can be used by health planners to estimate additional money required to achieve a certain level of coverage of programs, and it can be adjusted for different costs and program delivery parameters in different settings. Copyright © 2012 John Wiley & Sons, Ltd.

  4. SU-G-BRC-08: Evaluation of Dose Mass Histogram as a More Representative Dose Description Method Than Dose Volume Histogram in Lung Cancer Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, J; Eldib, A; Ma, C

    2016-06-15

    Purpose: Dose-volume-histogram (DVH) is widely used for plan evaluation in radiation treatment. The concept of dose-mass-histogram (DMH) is expected to provide a more representative description as it accounts for heterogeneity in tissue density. This study is intended to assess the difference between DVH and DMH for evaluating treatment planning quality. Methods: 12 lung cancer treatment plans were exported from the treatment planning system. DVHs for the planning target volume (PTV), the normal lung and other structures of interest were calculated. DMHs were calculated in a similar way as DVHs expect that the voxel density converted from the CT number wasmore » used in tallying the dose histogram bins. The equivalent uniform dose (EUD) was calculated based on voxel volume and mass, respectively. The normal tissue complication probability (NTCP) in relation to the EUD was calculated for the normal lung to provide quantitative comparison of DVHs and DMHs for evaluating the radiobiological effect. Results: Large differences were observed between DVHs and DMHs for lungs and PTVs. For PTVs with dense tumor cores, DMHs are higher than DVHs due to larger mass weighing in the high dose conformal core regions. For the normal lungs, DMHs can either be higher or lower than DVHs depending on the target location within the lung. When the target is close to the lower lung, DMHs show higher values than DVHs because the lower lung has higher density than the central portion or the upper lung. DMHs are lower than DVHs for targets in the upper lung. The calculated NTCPs showed a large range of difference between DVHs and DMHs. Conclusion: The heterogeneity of lung can be well considered using DMH for evaluating target coverage and normal lung pneumonitis. Further studies are warranted to quantify the benefits of DMH over DVH for plan quality evaluation.« less

  5. Vaccination coverage among children in kindergarten--United States, 2009-10 school year.

    PubMed

    2011-06-03

    Healthy People 2020 objectives include maintaining vaccination coverage among children in kindergarten (IID-10) (1). The target is ≥95% vaccination coverage for the following vaccines: poliovirus; diphtheria and tetanus toxoids and acellular pertussis (DTP/DTaP/DT); measles, mumps, and rubella (MMR); hepatitis B (HepB); and varicella (1). Data from school assessment surveys are used to monitor vaccination coverage and vaccination exemption levels among children enrolled in kindergarten. This report summarizes data from school assessment surveys submitted to CDC by 48 federal immunization program grantees (including 47 states and the District of Columbia) for the 2009-10 school year to describe vaccination coverage and exemption rates (2). For that period, 17 grantees reported coverage of ?95% for four vaccines (poliovirus, DTP/DTaP/DT, MMR, and HepB) and four grantees reported coverage of ≥95% for 2 doses of varicella vaccine. Total exemption rates, including medical, religious, and philosophical exemptions, ranged from <1% to 6.2% across grantees, and 15 grantees reported exemption rates<1%. Survey methods for vaccination coverage and exemption rates varied among grantees, making comparisons difficult and limiting the use of school assessment surveys to report aggregate national rates. Further standardization of school assessment survey methods will generate comparable data between grantees to monitor and track progress in reaching national objectives, and allow development of best practice guidelines for grantees to more effectively use and report school coverage and exemption data. CDC will continue to monitor vaccination coverage and exemption levels and assist grantees in identification of local areas with low vaccination coverage or high exemption rates for further evaluation or intervention.

  6. SU-F-T-600: Influence of Acuros XB and AAA Dose Calculation Algorithms On Plan Quality Metrics and Normal Lung Doses in Lung SBRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yaparpalvi, R; Mynampati, D; Kuo, H

    Purpose: To study the influence of superposition-beam model (AAA) and determinant-photon transport-solver (Acuros XB) dose calculation algorithms on the treatment plan quality metrics and on normal lung dose in Lung SBRT. Methods: Treatment plans of 10 Lung SBRT patients were randomly selected. Patients were prescribed to a total dose of 50-54Gy in 3–5 fractions (10?5 or 18?3). Doses were optimized accomplished with 6-MV using 2-arcs (VMAT). Doses were calculated using AAA algorithm with heterogeneity correction. For each plan, plan quality metrics in the categories- coverage, homogeneity, conformity and gradient were quantified. Repeat dosimetry for these AAA treatment plans was performedmore » using AXB algorithm with heterogeneity correction for same beam and MU parameters. Plan quality metrics were again evaluated and compared with AAA plan metrics. For normal lung dose, V{sub 20} and V{sub 5} to (Total lung- GTV) were evaluated. Results: The results are summarized in Supplemental Table 1. PTV volume was mean 11.4 (±3.3) cm{sup 3}. Comparing RTOG 0813 protocol criteria for conformality, AXB plans yielded on average, similar PITV ratio (individual PITV ratio differences varied from −9 to +15%), reduced target coverage (−1.6%) and increased R50% (+2.6%). Comparing normal lung doses, the lung V{sub 20} (+3.1%) and V{sub 5} (+1.5%) were slightly higher for AXB plans compared to AAA plans. High-dose spillage ((V105%PD - PTV)/ PTV) was slightly lower for AXB plans but the % low dose spillage (D2cm) was similar between the two calculation algorithms. Conclusion: AAA algorithm overestimates lung target dose. Routinely adapting to AXB for dose calculations in Lung SBRT planning may improve dose calculation accuracy, as AXB based calculations have been shown to be closer to Monte Carlo based dose predictions in accuracy and with relatively faster computational time. For clinical practice, revisiting dose-fractionation in Lung SBRT to correct for dose

  7. Vaccination Coverage Among Children Aged 2 Years - U.S. Affiliated Pacific Islands, April-October, 2016.

    PubMed

    Tippins, Ashley; Murthy, Neil; Meghani, Mehreen; Solsman, Amy; Apaisam, Carter; Basilius, Merlyn; Eckert, Maribeth; Judicpa, Peter; Masunu, Yolanda; Pistotnik, Kelsey; Pedro, Daisy; Sasamoto, Jeremy; Underwood, J Michael

    2018-05-25

    Vaccine-preventable diseases (VPDs) cause substantial morbidity and mortality in the United States Affiliated Pacific Islands (USAPI).* CDC collaborates with USAPI immunization programs to monitor vaccination coverage. In 2016, † USAPI immunization programs and CDC piloted a method for estimating up-to-date status among children aged 2 years using medical record abstraction to ascertain regional vaccination coverage. This was the first concurrent assessment of childhood vaccination coverage across five USAPI jurisdictions (American Samoa; Chuuk State, Federated States of Micronesia [FSM]; Commonwealth of the Northern Mariana Islands [CNMI]; Republic of the Marshall Islands [RMI]; and Republic of Palau). § Differences in vaccination coverage between main and outer islands ¶ were assessed for two jurisdictions where data were adequate.** Series coverage in this report includes the following doses of vaccines: ≥4 doses of diphtheria and tetanus toxoids and acellular pertussis vaccine (DTaP); ≥3 doses of inactivated poliovirus vaccine (IPV); ≥1 dose of measles, mumps, and rubella vaccine (MMR); ≥3 doses of Haemophilus influenzae type B (Hib) vaccine; ≥3 doses of hepatitis B (HepB) vaccine; and ≥4 doses of pneumococcal conjugate vaccine (PCV); i.e., 4:3:1:3:3:4. Coverage with ≥3 doses of rotavirus vaccine was also assessed. Completion of the recommended series of each of these vaccines †† was <90% in all jurisdictions except Palau. Coverage with the full recommended six-vaccine series (4:3:1:3:3:4) ranged from 19.5% (Chuuk) to 69.1% (Palau). In RMI and Chuuk, coverage was lower in the outer islands than in the main islands for most vaccines, with differences ranging from 0.9 to 66.8 percentage points. Medical record abstraction enabled rapid vaccination coverage assessment and timely dissemination of results to guide programmatic decision-making. Effectively monitoring vaccination coverage, coupled with implementation of data-driven interventions

  8. Determinants of vaccination coverage in rural Nigeria

    PubMed Central

    Odusanya, Olumuyiwa O; Alufohai, Ewan F; Meurice, Francois P; Ahonkhai, Vincent I

    2008-01-01

    Background Childhood immunization is a cost effective public health strategy. Expanded Programme on Immunisation (EPI) services have been provided in a rural Nigerian community (Sabongidda-Ora, Edo State) at no cost to the community since 1998 through a privately financed vaccination project (private public partnership). The objective of this survey was to assess vaccination coverage and its determinants in this rural community in Nigeria Methods A cross-sectional survey was conducted in September 2006, which included the use of interviewer-administered questionnaire to assess knowledge of mothers of children aged 12–23 months and vaccination coverage. Survey participants were selected following the World Health Organization's (WHO) immunization coverage cluster survey design. Vaccination coverage was assessed by vaccination card and maternal history. A child was said to be fully immunized if he or she had received all of the following vaccines: a dose of Bacille Calmette Guerin (BCG), three doses of oral polio (OPV), three doses of diphtheria, pertussis and tetanus (DPT), three doses of hepatitis B (HB) and one dose of measles by the time he or she was enrolled in the survey, i.e. between the ages of 12–23 months. Knowledge of the mothers was graded as satisfactory if mothers had at least a score of 3 out of a maximum of 5 points. Logistic regression was performed to identify determinants of full immunization status. Results Three hundred and thirty-nine mothers and 339 children (each mother had one eligible child) were included in the survey. Most of the mothers (99.1%) had very positive attitudes to immunization and > 55% were generally knowledgeable about symptoms of vaccine preventable diseases except for difficulty in breathing (as symptom of diphtheria). Two hundred and ninety-five mothers (87.0%) had a satisfactory level of knowledge. Vaccination coverage against all the seven childhood vaccine preventable diseases was 61.9% although it was

  9. Determinants of vaccination coverage in rural Nigeria.

    PubMed

    Odusanya, Olumuyiwa O; Alufohai, Ewan F; Meurice, Francois P; Ahonkhai, Vincent I

    2008-11-05

    Childhood immunization is a cost effective public health strategy. Expanded Programme on Immunisation (EPI) services have been provided in a rural Nigerian community (Sabongidda-Ora, Edo State) at no cost to the community since 1998 through a privately financed vaccination project (private public partnership). The objective of this survey was to assess vaccination coverage and its determinants in this rural community in Nigeria A cross-sectional survey was conducted in September 2006, which included the use of interviewer-administered questionnaire to assess knowledge of mothers of children aged 12-23 months and vaccination coverage. Survey participants were selected following the World Health Organization's (WHO) immunization coverage cluster survey design. Vaccination coverage was assessed by vaccination card and maternal history. A child was said to be fully immunized if he or she had received all of the following vaccines: a dose of Bacille Calmette Guerin (BCG), three doses of oral polio (OPV), three doses of diphtheria, pertussis and tetanus (DPT), three doses of hepatitis B (HB) and one dose of measles by the time he or she was enrolled in the survey, i.e. between the ages of 12-23 months. Knowledge of the mothers was graded as satisfactory if mothers had at least a score of 3 out of a maximum of 5 points. Logistic regression was performed to identify determinants of full immunization status. Three hundred and thirty-nine mothers and 339 children (each mother had one eligible child) were included in the survey. Most of the mothers (99.1%) had very positive attitudes to immunization and > 55% were generally knowledgeable about symptoms of vaccine preventable diseases except for difficulty in breathing (as symptom of diphtheria). Two hundred and ninety-five mothers (87.0%) had a satisfactory level of knowledge. Vaccination coverage against all the seven childhood vaccine preventable diseases was 61.9% although it was significantly higher (p = 0.002) amongst

  10. Implementation research: reactive mass vaccination with single-dose oral cholera vaccine, Zambia.

    PubMed

    Poncin, Marc; Zulu, Gideon; Voute, Caroline; Ferreras, Eva; Muleya, Clara Mbwili; Malama, Kennedy; Pezzoli, Lorenzo; Mufunda, Jacob; Robert, Hugues; Uzzeni, Florent; Luquero, Francisco J; Chizema, Elizabeth; Ciglenecki, Iza

    2018-02-01

    To describe the implementation and feasibility of an innovative mass vaccination strategy - based on single-dose oral cholera vaccine - to curb a cholera epidemic in a large urban setting. In April 2016, in the early stages of a cholera outbreak in Lusaka, Zambia, the health ministry collaborated with Médecins Sans Frontières and the World Health Organization in organizing a mass vaccination campaign, based on single-dose oral cholera vaccine. Over a period of 17 days, partners mobilized 1700 health ministry staff and community volunteers for community sensitization, social mobilization and vaccination activities in 10 townships. On each day, doses of vaccine were delivered to vaccination sites and administrative coverage was estimated. Overall, vaccination teams administered 424 100 doses of vaccine to an estimated target population of 578 043, resulting in an estimated administrative coverage of 73.4%. After the campaign, few cholera cases were reported and there was no evidence of the disease spreading within the vaccinated areas. The total cost of the campaign - 2.31 United States dollars (US$) per dose - included the relatively low cost of local delivery - US$ 0.41 per dose. We found that an early and large-scale targeted reactive campaign using a single-dose oral vaccine, organized in response to a cholera epidemic within a large city, to be feasible and appeared effective. While cholera vaccines remain in short supply, the maximization of the number of vaccines in response to a cholera epidemic, by the use of just one dose per member of an at-risk community, should be considered.

  11. Brachytherapy optimization using radiobiological-based planning for high dose rate and permanent implants for prostate cancer treatment

    NASA Astrophysics Data System (ADS)

    Seeley, Kaelyn; Cunha, J. Adam; Hong, Tae Min

    2017-01-01

    We discuss an improvement in brachytherapy--a prostate cancer treatment method that directly places radioactive seeds inside target cancerous regions--by optimizing the current standard for delivering dose. Currently, the seeds' spatiotemporal placement is determined by optimizing the dose based on a set of physical, user-defined constraints. One particular approach is the ``inverse planning'' algorithms that allow for tightly fit isodose lines around the target volumes in order to reduce dose to the patient's organs at risk. However, these dose distributions are typically computed assuming the same biological response to radiation for different types of tissues. In our work, we consider radiobiological parameters to account for the differences in the individual sensitivities and responses to radiation for tissues surrounding the target. Among the benefits are a more accurate toxicity rate and more coverage to target regions for planning high-dose-rate treatments as well as permanent implants.

  12. Immunisation coverage annual report, 2014.

    PubMed

    Hull, Brynley P; Hendry, Alexandra J; Dey, Aditi; Beard, Frank H; Brotherton, Julia M; McIntyre, Peter B

    2017-03-31

    This 8th annual immunisation coverage report shows data for 2014 derived from the Australian Childhood Immunisation Register and the National Human Papillomavirus Vaccination Program Register. This report includes coverage data for 'fully immunised' and by individual vaccines at standard age milestones and timeliness of receipt at earlier ages according to Indigenous status. Overall, 'fully immunised' coverage has been mostly stable at the 12- and 24-month age milestones since late 2003, but at 60 months of age, it has increased by more than 10 percentage points since 2009. As in previous years, coverage for 'fully immunised' at 12 months of age among Indigenous children was 3.7% lower than for non-Indigenous children overall, varying from 6.9 percentage points in Western Australia to 0.3 of a percentage point in the Australian Capital Territory. In 2014, 73.4% of Australian females aged 15 years had 3 documented doses of human papillomavirus vaccine (jurisdictional range 67.7% to 77.4%), and 82.7% had at least 1 dose, compared with 71.4% and 81.5%, respectively, in 2013. The disparity in on-time vaccination between Indigenous and non-Indigenous children in 2014 diminished progressively from 20.2% for vaccines due by 12 months to 11.5% for those due by 24 months and 3.0% at 60 months of age.

  13. Inequalities in full immunization coverage: trends in low- and middle-income countries

    PubMed Central

    Barros, Aluísio JD; Wong, Kerry LM; Johnson, Hope L; Pariyo, George; França, Giovanny VA; Wehrmeister, Fernando C; Victora, Cesar G

    2016-01-01

    Abstract Objective To investigate disparities in full immunization coverage across and within 86 low- and middle-income countries. Methods In May 2015, using data from the most recent Demographic and Health Surveys and Multiple Indicator Cluster Surveys, we investigated inequalities in full immunization coverage – i.e. one dose of bacille Calmette-Guérin vaccine, one dose of measles vaccine, three doses of vaccine against diphtheria, pertussis and tetanus and three doses of polio vaccine – in 86 low- or middle-income countries. We then investigated temporal trends in the level and inequality of such coverage in eight of the countries. Findings In each of the World Health Organization’s regions, it appeared that about 56–69% of eligible children in the low- and middle-income countries had received full immunization. However, within each region, the mean recorded level of such coverage varied greatly. In the African Region, for example, it varied from 11.4% in Chad to 90.3% in Rwanda. We detected pro-rich inequality in such coverage in 45 of the 83 countries for which the relevant data were available and pro-urban inequality in 35 of the 86 study countries. Among the countries in which we investigated coverage trends, Madagascar and Mozambique appeared to have made the greatest progress in improving levels of full immunization coverage over the last two decades, particularly among the poorest quintiles of their populations. Conclusion Most low- and middle-income countries are affected by pro-rich and pro-urban inequalities in full immunization coverage that are not apparent when only national mean values of such coverage are reported. PMID:27821882

  14. Evaluating Childhood Vaccination Coverage of NIP Vaccines: Coverage Survey versus Zhejiang Provincial Immunization Information System

    PubMed Central

    Hu, Yu; Chen, Yaping

    2017-01-01

    Vaccination coverage in Zhejiang province, east China, is evaluated through repeated coverage surveys. The Zhejiang provincial immunization information system (ZJIIS) was established in 2004 with links to all immunization clinics. ZJIIS has become an alternative to quickly assess the vaccination coverage. To assess the current completeness and accuracy on the vaccination coverage derived from ZJIIS, we compared the estimates from ZJIIS with the estimates from the most recent provincial coverage survey in 2014, which combined interview data with verified data from ZJIIS. Of the enrolled 2772 children in the 2014 provincial survey, the proportions of children with vaccination cards and registered in ZJIIS were 94.0% and 87.4%, respectively. Coverage estimates from ZJIIS were systematically higher than the corresponding estimates obtained through the survey, with a mean difference of 4.5%. Of the vaccination doses registered in ZJIIS, 16.7% differed from the date recorded in the corresponding vaccination cards. Under-registration in ZJIIS significantly influenced the coverage estimates derived from ZJIIS. Therefore, periodic coverage surveys currently provide more complete and reliable results than the estimates based on ZJIIS alone. However, further improvement of completeness and accuracy of ZJIIS will likely allow more reliable and timely estimates in future. PMID:28696387

  15. Evaluating Childhood Vaccination Coverage of NIP Vaccines: Coverage Survey versus Zhejiang Provincial Immunization Information System.

    PubMed

    Hu, Yu; Chen, Yaping

    2017-07-11

    Vaccination coverage in Zhejiang province, east China, is evaluated through repeated coverage surveys. The Zhejiang provincial immunization information system (ZJIIS) was established in 2004 with links to all immunization clinics. ZJIIS has become an alternative to quickly assess the vaccination coverage. To assess the current completeness and accuracy on the vaccination coverage derived from ZJIIS, we compared the estimates from ZJIIS with the estimates from the most recent provincial coverage survey in 2014, which combined interview data with verified data from ZJIIS. Of the enrolled 2772 children in the 2014 provincial survey, the proportions of children with vaccination cards and registered in ZJIIS were 94.0% and 87.4%, respectively. Coverage estimates from ZJIIS were systematically higher than the corresponding estimates obtained through the survey, with a mean difference of 4.5%. Of the vaccination doses registered in ZJIIS, 16.7% differed from the date recorded in the corresponding vaccination cards. Under-registration in ZJIIS significantly influenced the coverage estimates derived from ZJIIS. Therefore, periodic coverage surveys currently provide more complete and reliable results than the estimates based on ZJIIS alone. However, further improvement of completeness and accuracy of ZJIIS will likely allow more reliable and timely estimates in future.

  16. Seasonal influenza vaccine coverage among high-risk populations in Thailand, 2010–2012

    PubMed Central

    Owusu, Jocelynn T.; Prapasiri, Prabda; Ditsungnoen, Darunee; Leetongin, Grit; Yoocharoen, Pornsak; Rattanayot, Jarowee; Olsen, Sonja J.; Muangchana, Charung

    2015-01-01

    Background The Advisory Committee on Immunization Practice of Thailand prioritizes seasonal influenza vaccinations for populations who are at highest risk for serious complications (pregnant women, children 6 months–2 years, persons ≥65 years, persons with chronic diseases, obese persons), and health-care personnel and poultry cullers. The Thailand government purchases seasonal influenza vaccine for these groups. We assessed vaccination coverage among high-risk groups in Thailand from 2010 to 2012. Methods National records on persons who received publicly purchased vaccines from 2010 to 2012 were analyzed by high-risk category. Denominator data from multiple sources were compared to calculate coverage. Vaccine coverage was defined as the proportion of individuals in each category who received the vaccine. Vaccine wastage was defined as the proportion of publicly purchased vaccines that were not used. Results From 2010 to 2012, 8.18 million influenza vaccines were publicly purchased (range, 2.37–3.29 million doses/year), and vaccine purchases increased 39% over these years. Vaccine wastage was 9.5%. Approximately 5.7 million (77%) vaccine doses were administered to persons ≥65 years and persons with chronic diseases, 1.4 million (19%) to healthcare personnel/poultry cullers, 82,570 (1.1%) to children 6 months–2 years, 78,885 (1.1%) to obese persons, 26,481 (0.4%) to mentally disabled persons, and 17,787 (0.2%) to pregnant women. Between 2010 and 2012, coverage increased among persons with chronic diseases (8.6% versus 14%; p < 0.01) and persons ≥65 years (12%, versus 20%; p < 0.01); however, coverage decreased for mentally disabled persons (6.1% versus 4.9%; p < 0.01), children 6 months–2 years (2.3% versus 0.9%; p < 0.01), pregnant women (1.1% versus 0.9%; p < 0.01), and obese persons (0.2% versus 0.1%; p < 0.01). Conclusions From 2010 to 2012, the availability of publicly purchased vaccines increased. While coverage remained low for all target groups

  17. Dosimetric Advantages of Midventilation Compared With Internal Target Volume for Radiation Therapy of Pancreatic Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lens, Eelco, E-mail: e.lens@amc.uva.nl; Horst, Astrid van der; Versteijne, Eva

    2015-07-01

    Purpose: The midventilation (midV) approach can be used to take respiratory-induced pancreatic tumor motion into account during radiation therapy. In this study, the dosimetric consequences for organs at risk and tumor coverage of using a midV approach compared with using an internal target volume (ITV) were investigated. Methods and Materials: For each of the 18 patients, 2 treatment plans (25 × 2.0 Gy) were created, 1 using an ITV and 1 using a midV approach. The midV dose distribution was blurred using the respiratory-induced motion from 4-dimensional computed tomography. The resulting planning target volume (PTV) coverage for this blurred dosemore » distribution was analyzed; PTV coverage was required to be at least V{sub 95%} >98%. In addition, the change in PTV size and the changes in V{sub 10Gy}, V{sub 20Gy}, V{sub 30Gy}, V{sub 40Gy}, D{sub mean} and D{sub 2cc} for the stomach and for the duodenum were analyzed; differences were tested for significance using the Wilcoxon signed-rank test. Results: Using a midV approach resulted in sufficient target coverage. A highly significant PTV size reduction of 13.9% (P<.001) was observed. Also, all dose parameters for the stomach and duodenum, except the D{sub 2cc} of the duodenum, improved significantly (P≤.002). Conclusions: By using the midV approach to account for respiratory-induced tumor motion, a significant PTV reduction and significant dose reductions to the stomach and to the duodenum can be achieved when irradiating pancreatic tumors.« less

  18. Sci-Thur PM – Brachytherapy 05: Surface Collimation Applied to Superficial Flap High Dose-Rate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Derek; Sabondjian, Eric; Lawrence, Kailin

    Purpose: To apply surface collimation for superficial flap HDR skin brachytherapy utilizing common clinical resources and to demonstrate the potential for OAR dose reduction within a clinically relevant setting. Methods: Two phantom setups were used. 3 mm lead collimation was applied to a solid slab phantom to determine appropriate geometries relating to collimation and dwell activation. The same collimation was applied to the temple of an anthropomorphic head phantom to demonstrate lens dose reduction. Each setup was simulated and planned to deliver 400 cGy to a 3 cm circular target to 3 mm depth. The control and collimated irradiations weremore » sequentially measured using calibrated radiochromic films. Results: Collimation for the slab phantom attenuated the dose beyond the collimator opening, decreasing the fall-off distances by half and reducing the area of healthy skin irradiated. Target coverage can be negatively impacted by a tight collimation margin, with the required margin approximated by the primary beam geometric penumbra. Surface collimation applied to the head phantom similarly attenuated the surrounding normal tissue dose while reducing the lens dose from 84 to 68 cGy. To ensure consistent setup between simulation and treatment, additional QA was performed including collimator markup, accounting for collimator placement uncertainties, standoff distance verification, and in vivo dosimetry. Conclusions: Surface collimation was shown to reduce normal tissue dose without compromising target coverage. Lens dose reduction was demonstrated on an anthropomorphic phantom within a clinical setting. Additional QA is proposed to ensure treatment fidelity.« less

  19. Three-dimensional dose verification of the clinical application of gamma knife stereotactic radiosurgery using polymer gel and MRI.

    PubMed

    Papagiannis, P; Karaiskos, P; Kozicki, M; Rosiak, J M; Sakelliou, L; Sandilos, P; Seimenis, I; Torrens, M

    2005-05-07

    This work seeks to verify multi-shot clinical applications of stereotactic radiosurgery with a Leksell Gamma Knife model C unit employing a polymer gel-MRI based experimental procedure, which has already been shown to be capable of verifying the precision and accuracy of dose delivery in single-shot gamma knife applications. The treatment plan studied in the present work resembles a clinical treatment case of pituitary adenoma using four 8 mm and one 14 mm collimator helmet shots to deliver a prescription dose of 15 Gy to the 50% isodose line (30 Gy maximum dose). For the experimental dose verification of the treatment plan, the same criteria as those used in the clinical treatment planning evaluation were employed. These included comparison of measured and GammaPlan calculated data, in terms of percentage isodose contours on axial, coronal and sagittal planes, as well as 3D plan evaluation criteria such as dose-volume histograms for the target volume, target coverage and conformity indices. Measured percentage isodose contours compared favourably with calculated ones despite individual point fluctuations at low dose contours (e.g., 20%) mainly due to the effect of T2 measurement uncertainty on dose resolution. Dose-volume histogram data were also found in a good agreement while the experimental results for the percentage target coverage and conformity index were 94% and 1.17 relative to corresponding GammaPlan calculations of 96% and 1.12, respectively. Overall, polymer gel results verified the planned dose distribution within experimental uncertainties and uncertainty related to the digitization process of selected GammaPlan output data.

  20. Influence of Residual Tumor Volume and Radiation Dose Coverage in Outcomes for Clival Chordoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McDonald, Mark W., E-mail: markmcdonaldmd@gmail.com; Indiana University Health Proton Therapy Center, Bloomington, Indiana; Linton, Okechukwu R.

    2016-05-01

    Purpose: The purpose of this study was to evaluate factors associated with tumor control in clival chordomas. Methods and Materials: A retrospective review of 39 patients treated with surgery and proton therapy for clival chordomas between 2004 and 2014 was performed. The median prescribed dose was 77.4 Gy (relative biological effectiveness [RBE]); range was 70.2-79.2 Gy (RBE). Minimum and median doses to gross tumor volume (GTV), radiation dose received by 1 cm{sup 3} of GTV (D1cm{sup 3}), and the equivalent uniform dose were calculated. Receiver operating characteristics curves evaluated the predictive sensitivity and specificity for local failure of potential cutpoint values for GTVmore » and D1cm{sup 3}. Results: After a median follow-up of 51 months, the 5-year estimate of local control (LC) was 69.6% (95% confidence interval [CI] 50.0%-89.2%), and overall survival (OS) was 81.4% (95% CI: 65.3%-97.5%). Tumor histology, GTV at the time of radiation, and prescribed radiation dose were significantly associated with local control on multivariate analysis, whereas D1cm{sup 3} was associated with overall survival. Compared to those patients whose conditions remained controlled, patients experiencing tumor failure had statistically significant larger GTVs and lower D1cm{sup 3}, and prescribed and median doses to GTV. A subset of 21 patients with GTV of ≤20 cm{sup 3} and D1cm{sup 3} of >67 Gy (RBE) had a median follow-up of 47 months. The 5-year estimate of local control in this subset was 81.1% (95% CI: 61.7%-100%; P=.004, overall comparison by GTV ≤20 cm{sup 3} stratified by D1cm{sup 3}). A D1cm{sup 3} of 74.5 Gy (RBE) had 80% sensitivity for local control and 60% specificity, whereas a GTV of 9.3 cm{sup 3} had 80% sensitivity for local control and 66.7% specificity. Conclusions: Local control of clival chordomas was associated with both smaller size of residual tumor and more complete high-dose coverage of residual tumor. Multidisciplinary care

  1. A novel concept for tumour targeting with radiation: Inverse dose-painting or targeting the "Low Drug Uptake Volume".

    PubMed

    Yaromina, Ala; Granzier, Marlies; Biemans, Rianne; Lieuwes, Natasja; van Elmpt, Wouter; Shakirin, Georgy; Dubois, Ludwig; Lambin, Philippe

    2017-09-01

    We tested a novel treatment approach combining (1) targeting radioresistant hypoxic tumour cells with the hypoxia-activated prodrug TH-302 and (2) inverse radiation dose-painting to boost selectively non-hypoxic tumour sub-volumes having no/low drug uptake. 18 F-HX4 hypoxia tracer uptake measured with a clinical PET/CT scanner was used as a surrogate of TH-302 activity in rhabdomyosarcomas growing in immunocompetent rats. Low or high drug uptake volume (LDUV/HDUV) was defined as 40% of the GTV with the lowest or highest 18 F-HX4 uptake, respectively. Two hours post TH-302/saline administration, animals received either single dose radiotherapy (RT) uniformly (15 or 18.5Gy) or a dose-painted non-uniform radiation (15Gy) with 50% higher dose to LDUV or HDUV (18.5Gy). Treatment plans were created using Eclipse treatment planning system and radiation was delivered using VMAT. Tumour response was quantified as time to reach 3 times starting tumour volume. Non-uniform RT boosting tumour sub-volume with low TH-302 uptake (LDUV) was superior to the same dose escalation to HDUV (p<0.0001) and uniform RT with the same mean dose 15Gy (p=0.0077). Noteworthy, dose escalation to LDUV required on average 3.5Gy lower dose to the GTV to achieve similar tumour response as uniform dose escalation. The results support targeted dose escalation to non-hypoxic tumour sub-volume with no/low activity of hypoxia-activated prodrugs. This strategy applies on average a lower radiation dose and is as effective as uniform dose escalation to the entire tumour. It could be applied to other type of drugs provided that their distribution can be imaged. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  2. Coverage and cost of a large oral cholera vaccination program in a high-risk cholera endemic urban population in Dhaka, Bangladesh.

    PubMed

    Khan, Iqbal Ansary; Saha, Amit; Chowdhury, Fahima; Khan, Ashraful Islam; Uddin, Md Jasim; Begum, Yasmin A; Riaz, Baizid Khoorshid; Islam, Sanjida; Ali, Mohammad; Luby, Stephen P; Clemens, John D; Cravioto, Alejandro; Qadri, Firdausi

    2013-12-09

    A feasibility study of an oral cholera vaccine was carried out to test strategies to reach high-risk populations in urban Mirpur, Dhaka, Bangladesh. The study was cluster randomized, with three arms: vaccine, vaccine plus safe water and hand washing practice, and no intervention. High risk people of age one year and above (except pregnant woman) from the two intervention arms received two doses of the oral cholera vaccine, Shanchol™. Vaccination was conducted between 17th February and 16th April 2011, with a minimum interval of fourteen days between two doses. Interpersonal communication preceded vaccination to raise awareness amongst the target population. The number of vaccine doses used, the population vaccinated, left-out, drop out, vaccine wastage and resources required were documented. Fixed outreach site vaccination strategy was adopted as the mode of vaccine delivery. Additionally, mobile vaccination sites and mop-up activities were carried out to reach the target communities. Of the 172,754 target population, 141,839 (82%) and 123,666 (72%) received complete first and second doses of the vaccine, respectively. Dropout rate from the first to the second dose was 13%. Two complete doses were received by 123,661 participants. Vaccine coverage in children was 81%. Coverage was significantly higher in females than in males (77% vs. 66%, P<0.001). Vaccine wastage for delivering the complete doses was 1.2%. The government provided cold-chain related support at no cost to the project. Costs for two doses of vaccine per-person were US$3.93, of which US$1.63 was spent on delivery. Cost for delivering a single dose was US$0.76. We observed no serious adverse events. Mass vaccination with oral cholera vaccine is feasible for reaching high risk endemic population through the existing national immunization delivery system employed by the government. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Low-wage workers and health insurance coverage: can policymakers target them through their employers?

    PubMed

    Long, S H; Marquis, M S

    2001-01-01

    Many policy initiatives to increase health insurance coverage would subsidize employers to offer coverage or subsidize employees to participate in their employers' health plans. Using data from the 1997 Robert Wood Johnson Foundation Employer Health Insurance Survey, we contrast "low-wage employers" with all other employers. Employees in low-wage businesses have significantly worse access to employment-based insurance than other employees do; they are less likely to work for an employer that offers insurance, less likely to be eligible if working in a business that offers insurance, and less likely to be enrolled if eligible. Low-wage employers contribute lower shares of premiums and offer less generous benefits than other employers do. Policies that would target subsidies to selected employers to increase insurance offers to low-wage workers are difficult to design, however, because several commonly mentioned employer characteristics (including firm size) are found to be poor indicators of low-wage worker concentration. Programs that would set minimum standards for employer plans to be eligible for "buy-ins" need to base these standards on the less generous terms offered by low-wage employers in order to effectively reach low-wage workers and their dependents.

  4. SU-F-T-568: QA of a Multi-Target Multi-Dose VMAT SRS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roa, D; Kuo, J; Gonzales, A

    2016-06-15

    Purpose: To, experimentally, corroborated the prescribed doses utilizing dosimeters (e.g. films and TLDs) that can provide high spatial resolution, allow dose measurement of multiple targets at once, and provide accurate dosimetric results. Methods: A single-isocenter 6FFF SRS VMAT plan consisting of one 358° arc at 0° couch angle and four 179° arcs at 30°, 60°, 330° and 300° couch angles respectively, was generated in ECLIPSE v.11 using a Rando-Alderson anthropomorphic head phantom CT study. This plan was a reproduction of a clinical plan generated for a stage-IV melanoma patient diagnosed with 19 intracranial lesions. The phantom was loaded with axiallymore » mounted (between phantom slabs) Gafchromic EBT3 film and TLDs strategically positioned within various target volumes. Film and TLDS were calibrated according to established protocols. Target prescription doses were 16 Gy (3cc≤, 3 lesions), 18 Gy (∼1–3cc, 10 lesions) and 20 Gy (≤1cc, 6 lesions). Phantom setup was verified through CBCT imaging prior to irradiation. Gafchromic films were scanned in transmission mode and TLDs were read, respectively, ∼24 hrs after irradiation. Results: Dose calibrated Gafchromic film data were compared to the ECLIPSE calculated data using a 3% / 3mm gamma function analysis. Results for the gamma values were 96–99% in agreement with the calculated data and with 84–90% of the film pixels within the 3% dose difference. TLD data showed a dose difference of 0.4–8% while the film data for those same locations yielded a difference of 0.4–4%. It was observed that the highest dose discrepancies correlated with the location of the small volume targets. Conclusion: Overall this study corroborated that a VMAT SRS treatment, employing various treatment table rotations and arcs, to multiple intracranial lesions with multiple dose prescriptions can be delivered accurately with the existing radiotherapy technology.« less

  5. Implementation research: reactive mass vaccination with single-dose oral cholera vaccine, Zambia

    PubMed Central

    Zulu, Gideon; Voute, Caroline; Ferreras, Eva; Muleya, Clara Mbwili; Malama, Kennedy; Pezzoli, Lorenzo; Mufunda, Jacob; Robert, Hugues; Uzzeni, Florent; Luquero, Francisco J; Chizema, Elizabeth; Ciglenecki, Iza

    2018-01-01

    Abstract Objective To describe the implementation and feasibility of an innovative mass vaccination strategy – based on single-dose oral cholera vaccine – to curb a cholera epidemic in a large urban setting. Method In April 2016, in the early stages of a cholera outbreak in Lusaka, Zambia, the health ministry collaborated with Médecins Sans Frontières and the World Health Organization in organizing a mass vaccination campaign, based on single-dose oral cholera vaccine. Over a period of 17 days, partners mobilized 1700 health ministry staff and community volunteers for community sensitization, social mobilization and vaccination activities in 10 townships. On each day, doses of vaccine were delivered to vaccination sites and administrative coverage was estimated. Findings Overall, vaccination teams administered 424 100 doses of vaccine to an estimated target population of 578 043, resulting in an estimated administrative coverage of 73.4%. After the campaign, few cholera cases were reported and there was no evidence of the disease spreading within the vaccinated areas. The total cost of the campaign – 2.31 United States dollars (US$) per dose – included the relatively low cost of local delivery – US$ 0.41 per dose. Conclusion We found that an early and large-scale targeted reactive campaign using a single-dose oral vaccine, organized in response to a cholera epidemic within a large city, to be feasible and appeared effective. While cholera vaccines remain in short supply, the maximization of the number of vaccines in response to a cholera epidemic, by the use of just one dose per member of an at-risk community, should be considered. PMID:29403111

  6. Association of Health Insurance Status and Vaccination Coverage among Adolescents 13-17 Years of Age.

    PubMed

    Lu, Peng-Jun; Yankey, David; Jeyarajah, Jenny; O'Halloran, Alissa; Fredua, Benjamin; Elam-Evans, Laurie D; Reagan-Steiner, Sarah

    2018-04-01

    To assess selected vaccination coverage among adolescents by health insurance status and other access-to-care characteristics. The 2015 National Immunization Survey-Teen data were used to assess vaccination coverage disparities among adolescents by health insurance status and other access-to-care variables. Multivariable logistic regression analysis and a predictive marginal modeling were conducted to evaluate associations between health insurance status and vaccination coverage. Overall, vaccination coverage was significantly lower among uninsured compared with insured adolescents for all vaccines assessed for except ≥3 doses of human papillomavirus vaccine (HPV) among male adolescents. Among adolescents 13-17 years of age, vaccination of uninsured compared with insured adolescents, respectively, for tetanus toxoid, reduced content diphtheria toxoid, and acellular pertussis vaccine was 77.4% vs 86.8%; for ≥1 dose of meningococcal conjugate vaccine was 72.9% vs 81.7%; for ≥1 dose of HPV was 38.8% vs 50.2% among male and 42.9% vs 63.8% among female adolescents; for 3 doses of HPV was 24.9% vs 42.8% among female adolescents. In addition, vaccination coverage differed by the following: type of insurance among insured adolescents, having a well-child visit at 11-12 years of age, and number of healthcare provider contacts in the past year. Uninsured were less likely than insured adolescents to be vaccinated for HPV (female: ≥1 dose and 3 doses; and male: ≥1 doses) after adjusting for confounding variables. Overall, vaccination coverage was lower among uninsured adolescents. HPV vaccination coverage was lower than tetanus toxoid, reduced content diphtheria toxoid, and acellular pertussis vaccine Tdap and meningococcal conjugate vaccine in both insured and uninsured adolescents. Wider implementation of effective evidence-based strategies is needed to help improve vaccination coverage among adolescents, particularly for those who are uninsured. Limitation of

  7. Highly targeted cholera vaccination campaigns in urban setting are feasible: The experience in Kalemie, Democratic Republic of Congo

    PubMed Central

    Massing, Louis Albert; Aboubakar, Soumah; Page, Anne-Laure; Cohuet, Sandra; Ngandwe, Adalbert; Mukomena Sompwe, Eric; Ramazani, Romain; Allheimen, Marcela; Levaillant, Philippe; Lechevalier, Pauline; Kashimi, Marie; de la Motte, Axelle; Calmejane, Arielle; Bouhenia, Malika; Dabire, Ernest; Bompangue, Didier; Kebela, Benoit; Porten, Klaudia

    2018-01-01

    Introduction Oral cholera vaccines are primarily recommended by the World Health Organization for cholera control in endemic countries. However, the number of cholera vaccines currently produced is very limited and examples of OCV use in endemic countries, and especially in urban settings, are scarce. A vaccination campaign was organized by Médecins Sans Frontières and the Ministry of Health in a highly endemic area in the Democratic Republic of Congo. This study aims to describe the vaccine coverage achieved with this highly targeted vaccination campaign and the acceptability among the vaccinated communities. Methods and findings We performed a cross-sectional survey using random spatial sampling. The study population included individuals one year old and above, eligible for vaccination, and residing in the areas targeted for vaccination in the city of Kalemie. Data sources were household interviews with verification by vaccination card. In total 2,488 people were included in the survey. Overall, 81.9% (95%CI: 77.9–85.3) of the target population received at least one dose of vaccine. The vaccine coverage with two doses was 67.2% (95%CI: 61.9–72.0) among the target population. The vaccine coverage was higher during the first round (74.0, 95%CI: 69.3–78.3) than during the second round of vaccination (69.1%, 95%CI: 63.9–74.0). Vaccination coverage was lower in male adults. The main reason for non-vaccination was to be absent during the campaign. No severe adverse events were notified during the interviews. Conclusions Cholera vaccination campaigns using highly targeted strategies are feasible in urban settings. High vaccination coverage can be obtained using door to door vaccination. However, alternative strategies should be considered to reach non-vaccinated populations like male adults and also in order to improve the efficiency of the interventions. PMID:29734337

  8. Estimating the coverage of mental health programmes: a systematic review

    PubMed Central

    De Silva, Mary J; Lee, Lucy; Fuhr, Daniela C; Rathod, Sujit; Chisholm, Dan; Schellenberg, Joanna; Patel, Vikram

    2014-01-01

    Background The large treatment gap for people suffering from mental disorders has led to initiatives to scale up mental health services. In order to track progress, estimates of programme coverage, and changes in coverage over time, are needed. Methods Systematic review of mental health programme evaluations that assess coverage, measured either as the proportion of the target population in contact with services (contact coverage) or as the proportion of the target population who receive appropriate and effective care (effective coverage). We performed a search of electronic databases and grey literature up to March 2013 and contacted experts in the field. Methods to estimate the numerator (service utilization) and the denominator (target population) were reviewed to explore methods which could be used in programme evaluations. Results We identified 15 735 unique records of which only seven met the inclusion criteria. All studies reported contact coverage. No study explicitly measured effective coverage, but it was possible to estimate this for one study. In six studies the numerator of coverage, service utilization, was estimated using routine clinical information, whereas one study used a national community survey. The methods for estimating the denominator, the population in need of services, were more varied and included national prevalence surveys case registers, and estimates from the literature. Conclusions Very few coverage estimates are available. Coverage could be estimated at low cost by combining routine programme data with population prevalence estimates from national surveys. PMID:24760874

  9. Estimating the coverage of mental health programmes: a systematic review.

    PubMed

    De Silva, Mary J; Lee, Lucy; Fuhr, Daniela C; Rathod, Sujit; Chisholm, Dan; Schellenberg, Joanna; Patel, Vikram

    2014-04-01

    The large treatment gap for people suffering from mental disorders has led to initiatives to scale up mental health services. In order to track progress, estimates of programme coverage, and changes in coverage over time, are needed. Systematic review of mental health programme evaluations that assess coverage, measured either as the proportion of the target population in contact with services (contact coverage) or as the proportion of the target population who receive appropriate and effective care (effective coverage). We performed a search of electronic databases and grey literature up to March 2013 and contacted experts in the field. Methods to estimate the numerator (service utilization) and the denominator (target population) were reviewed to explore methods which could be used in programme evaluations. We identified 15 735 unique records of which only seven met the inclusion criteria. All studies reported contact coverage. No study explicitly measured effective coverage, but it was possible to estimate this for one study. In six studies the numerator of coverage, service utilization, was estimated using routine clinical information, whereas one study used a national community survey. The methods for estimating the denominator, the population in need of services, were more varied and included national prevalence surveys case registers, and estimates from the literature. Very few coverage estimates are available. Coverage could be estimated at low cost by combining routine programme data with population prevalence estimates from national surveys.

  10. SU-F-T-36: Dosimetric Comparison of Point Based Vs. Target Based Prescription for Intracavitary Brachytherapy in Cancer of the Cervix

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ashenafi, M; McDonald, D; Peng, J

    Purpose: Improved patient imaging used for planning the treatment of cervical cancer with Tandem and Ovoid (T&O) Intracavitary high-dose-rate brachytherapy (HDR) now allows for 3D delineation of target volumes and organs-at-risk. However, historical data relies on the conventional point A-based planning technique. A comparative dosimetric study was performed by generating both target-based (TBP) and point-based (PBP) plans for ten clinical patients. Methods: Treatment plans created using Elekta Oncentra v. 4.3 for ten consecutive cervical cancer patients were analyzed. All patients were treated with HDR using the Utrecht T&O applicator. Both CT and MRI imaging modalities were utilized to delineate clinicalmore » target volume (CTV) and organs-at-risk (rectum, sigmoid, bladder, and small bowel). Point A (left and right), vaginal mucosa, and ICRU rectum and bladder points were defined on CT. Two plans were generated for each patient using two prescription methods (PBP and TBP). 7Gy was prescribed to each point A for each PBP plan and to the target D90% for each TBP plan. Target V90%, V100%, and V200% were evaluated. In addition, D0.1cc and D2cc were analyzed for each organ-at-risk. Differences were assessed for statistical significance (p<0.05) by use of Student’s t-test. Results: Target coverage was comparable for both planning methods, with each method providing adequate target coverage. TBP showed lower absolute dose to the target volume than PBP (D90% = 7.0Gy vs. 7.4Gy, p=0.028), (V200% = 10.9cc vs. 12.8cc, p=0.014), (ALeft = 6.4Gy vs. 7Gy, p=0.009), and (ARight = 6.4Gy vs. 7Gy, p=0.013). TBP also showed a statistically significant reduction in bladder, rectum, small bowel, and sigmoid doses compared to PBP. There was no statistically significant difference in vaginal mucosa or ICRU-defined rectum and bladder dose. Conclusion: Target based prescription resulted in substantially lower dose to delineated organs-at-risk compared to point based prescription

  11. Calculation of Absorbed Dose in Target Tissue and Equivalent Dose in Sensitive Tissues of Patients Treated by BNCT Using MCNP4C

    NASA Astrophysics Data System (ADS)

    Zamani, M.; Kasesaz, Y.; Khalafi, H.; Pooya, S. M. Hosseini

    Boron Neutron Capture Therapy (BNCT) is used for treatment of many diseases, including brain tumors, in many medical centers. In this method, a target area (e.g., head of patient) is irradiated by some optimized and suitable neutron fields such as research nuclear reactors. Aiming at protection of healthy tissues which are located in the vicinity of irradiated tissue, and based on the ALARA principle, it is required to prevent unnecessary exposure of these vital organs. In this study, by using numerical simulation method (MCNP4C Code), the absorbed dose in target tissue and the equiavalent dose in different sensitive tissues of a patiant treated by BNCT, are calculated. For this purpose, we have used the parameters of MIRD Standard Phantom. Equiavelent dose in 11 sensitive organs, located in the vicinity of target, and total equivalent dose in whole body, have been calculated. The results show that the absorbed dose in tumor and normal tissue of brain equal to 30.35 Gy and 0.19 Gy, respectively. Also, total equivalent dose in 11 sensitive organs, other than tumor and normal tissue of brain, is equal to 14 mGy. The maximum equivalent doses in organs, other than brain and tumor, appear to the tissues of lungs and thyroid and are equal to 7.35 mSv and 3.00 mSv, respectively.

  12. Dosing Schedules for Pneumococcal Conjugate Vaccine

    PubMed Central

    2014-01-01

    Since second generation pneumococcal conjugate vaccines (PCVs) targeting 10 and 13 serotypes became available in 2010, the number of national policy makers considering these vaccines has steadily increased. An important consideration for a national immunization program is the timing and number of doses—the schedule—that will best prevent disease in the population. Data on disease epidemiology and the efficacy or effectiveness of PCV schedules are typically considered when choosing a schedule. Practical concerns, such as the existing vaccine schedule, and vaccine program performance are also important. In low-income countries, pneumococcal disease and deaths typically peak well before the end of the first year of life, making a schedule that provides PCV doses early in life (eg, a 6-, 10- and 14-week schedule) potentially the best option. In other settings, a schedule including a booster dose may address disease that peaks in the second year of life or may be seen to enhance a schedule already in place. A large and growing body of evidence from immunogenicity studies, as well as clinical trials and observational studies of carriage, pneumonia and invasive disease, has been systematically reviewed; these data indicate that schedules of 3 or 4 doses all work well, and that the differences between these regimens are subtle, especially in a mature program in which coverage is high and indirect (herd) effects help enhance protection provided directly by a vaccine schedule. The recent World Health Organization policy statement on PCVs endorsed a schedule of 3 primary doses without a booster or, as a new alternative, 2 primary doses with a booster dose. While 1 schedule may be preferred in a particular setting based on local epidemiology or practical considerations, achieving high coverage with 3 doses is likely more important than the specific timing of doses. PMID:24336059

  13. Evaluation of delivered dose for a clinical daily adaptive plan selection strategy for bladder cancer radiotherapy.

    PubMed

    Lutkenhaus, Lotte J; Visser, Jorrit; de Jong, Rianne; Hulshof, Maarten C C M; Bel, Arjan

    2015-07-01

    To account for variable bladder size during bladder cancer radiotherapy, a daily plan selection strategy was implemented. The aim of this study was to calculate the actually delivered dose using an adaptive strategy, compared to a non-adaptive approach. Ten patients were treated to the bladder and lymph nodes with an adaptive full bladder strategy. Interpolated delineations of bladder and tumor on a full and empty bladder CT scan resulted in five PTVs for which VMAT plans were created. Daily cone beam CT (CBCT) scans were used for plan selection. Bowel, rectum and target volumes were delineated on these CBCTs, and delivered dose for these was calculated using both the adaptive plan, and a non-adaptive plan. Target coverage for lymph nodes improved using an adaptive strategy. The full bladder strategy spared the healthy part of the bladder from a high dose. Average bowel cavity V30Gy and V40Gy significantly reduced with 60 and 69ml, respectively (p<0.01). Other parameters for bowel and rectum remained unchanged. Daily plan selection compared to a non-adaptive strategy yielded similar bladder coverage and improved coverage for lymph nodes, with a significant reduction in bowel cavity V30Gy and V40Gy only, while other sparing was limited. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  14. Modeling the target dose fall-off in IMRT and VMAT planning techniques for cervical SBRT.

    PubMed

    Brito Delgado, A; Cohen, D; Eng, T Y; Stanley, D N; Shi, Z; Charlton, M; Gutiérrez, A N

    2018-01-01

    There has been growing interest in the use of stereotactic body radiotherapy (SBRT) technique for the treatment of cervical cancer. The purpose of this study was to characterize dose distributions as well as model the target dose fall-off for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) delivery techniques using 6 and 10 MV photon beam energies. Fifteen (n = 15) patients with non-bulky cervical tumors were planned in Pinnacle 3 with a Varian Novalis Tx (HD120 MLC) using 6 and 10 MV photons with the following techniques: (1) IMRT with 10 non-coplanar beams (2) dual, coplanar 358° VMAT arcs (4° spacing), and (3) triple, non-coplanar VMAT arcs. Treatment volumes and dose prescriptions were segmented according to University of Texas Southwestern (UTSW) Phase II study. All plans were normalized such that 98% of the planning target volume (PTV) received 28 Gy (4 fractions). For the PTV, the following metrics were evaluated: homogeneity index, conformity index, D 2cc , D mean , D max , and dose fall-off parameters. For the organs at risk (OARs), D 2cc , D 15cc , D 0.01cc , V 20 , V 40 , V 50 , V 60 , and V 80 were evaluated for the bladder, bowel, femoral heads, rectum, and sigmoid. Statistical differences were evaluated using a Friedman test with a significance level of 0.05. To model dose fall-off, expanding 2-mm-thick concentric rings were created around the PTV, and doses were recorded. Statistically significant differences (p < 0.05) were noted in the dose fall-off when using 10 MV and VMAT 3-arc , as compared with IMRT. VMAT 3-arc improved the bladder V 40 , V 50 , and V 60 , and the bowel V 20 and V 50 . All fitted regressions had an R 2  ≥ 0.98. For cervical SBRT plans, a VMAT 3-arc approach offers a steeper dose fall-off outside of the target volume. Faster dose fall-off was observed in smaller targets as opposed to medium and large targets, denoting that OAR sparing is dependent on target size. These

  15. A Two-Phase Coverage-Enhancing Algorithm for Hybrid Wireless Sensor Networks.

    PubMed

    Zhang, Qingguo; Fok, Mable P

    2017-01-09

    Providing field coverage is a key task in many sensor network applications. In certain scenarios, the sensor field may have coverage holes due to random initial deployment of sensors; thus, the desired level of coverage cannot be achieved. A hybrid wireless sensor network is a cost-effective solution to this problem, which is achieved by repositioning a portion of the mobile sensors in the network to meet the network coverage requirement. This paper investigates how to redeploy mobile sensor nodes to improve network coverage in hybrid wireless sensor networks. We propose a two-phase coverage-enhancing algorithm for hybrid wireless sensor networks. In phase one, we use a differential evolution algorithm to compute the candidate's target positions in the mobile sensor nodes that could potentially improve coverage. In the second phase, we use an optimization scheme on the candidate's target positions calculated from phase one to reduce the accumulated potential moving distance of mobile sensors, such that the exact mobile sensor nodes that need to be moved as well as their final target positions can be determined. Experimental results show that the proposed algorithm provided significant improvement in terms of area coverage rate, average moving distance, area coverage-distance rate and the number of moved mobile sensors, when compare with other approaches.

  16. Dosimetric quality endpoints for low-dose-rate prostate brachytherapy using biological effective dose (bed) vs. conventional dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Rachana; Al-Hallaq, Hania; Pelizzari, Charles A.

    2003-12-31

    The purpose of this study was to compare conventional low-dose-rate prostate brachytherapy dosimetric quality parameters with their biological effective dose (BED) counterparts. To validate a model for transformation from conventional dose to BED, the postimplant plans of 31 prostate brachytherapy patients were evaluated using conventional dose-volume histogram (DVH) quality endpoints and analogous BED-DVH endpoints. Based on CT scans obtained 4 weeks after implantation, DVHs were computed and standard dosimetric endpoints V100 (volume receiving 100% of the prescribed dose), V150, V200, HI (1-[V150/V100]), and D90 (dose that 90% of the target volume received) were obtained for quality analysis. Using known andmore » reported transformations, dose grids were transformed to BED-early ({alpha}/{beta} = 10 Gy) and BED-late ({alpha}/{beta} = 3 Gy) grids, and the same dosimetric endpoints were analyzed. For conventional, BED-early and BED-late DVHs, no differences in V100 were seen (0.896, 0.893, and 0.894, respectively). However, V150 and V200 were significantly higher for both BED-early (0.582 and 0.316) and BED-late (0.595 and 0.337), compared with the conventional (0.539 and 0.255) DVHs. D90 was significantly lower for the BED-early (103.1 Gy) and BED-late transformations (106.9 Gy) as compared with the conventional (119.5 Gy) DVHs. The conventional prescription parameter V100 is the same for the corresponding BED-early and BED-late transformed DVHs. The toxicity parameters V150 and V200 are slightly higher using the BED transformations, suggesting that the BED doses are somewhat higher than predicted using conventional DVHs. The prescription/quality parameter D90 is slightly lower, implying that target coverage is lower than predicted using conventional DVHs. This methodology can be applied to analyze BED dosimetric endpoints to improve clinical outcome and reduce complications of prostate brachytherapy.« less

  17. Radiotherapy Dose-Volume Effects on Salivary Gland Function

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deasy, Joseph O., E-mail: jdeasy@radonc.wustl.ed; Moiseenko, Vitali; Marks, Lawrence

    2010-03-01

    Publications relating parotid dose-volume characteristics to radiotherapy-induced salivary toxicity were reviewed. Late salivary dysfunction has been correlated to the mean parotid gland dose, with recovery occurring with time. Severe xerostomia (defined as long-term salivary function of <25% of baseline) is usually avoided if at least one parotid gland is spared to a mean dose of less than {approx}20 Gy or if both glands are spared to less than {approx}25 Gy (mean dose). For complex, partial-volume RT patterns (e.g., intensity-modulated radiotherapy), each parotid mean dose should be kept as low as possible, consistent with the desired clinical target volume coverage. Amore » lower parotid mean dose usually results in better function. Submandibular gland sparing also significantly decreases the risk of xerostomia. The currently available predictive models are imprecise, and additional study is required to identify more accurate models of xerostomia risk.« less

  18. TH-A-19A-06: Site-Specific Comparison of Analytical and Monte Carlo Based Dose Calculations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schuemann, J; Grassberger, C; Paganetti, H

    2014-06-15

    Purpose: To investigate the impact of complex patient geometries on the capability of analytical dose calculation algorithms to accurately predict dose distributions and to verify currently used uncertainty margins in proton therapy. Methods: Dose distributions predicted by an analytical pencilbeam algorithm were compared with Monte Carlo simulations (MCS) using TOPAS. 79 complete patient treatment plans were investigated for 7 disease sites (liver, prostate, breast, medulloblastoma spine and whole brain, lung and head and neck). A total of 508 individual passively scattered treatment fields were analyzed for field specific properties. Comparisons based on target coverage indices (EUD, D95, D90 and D50)more » were performed. Range differences were estimated for the distal position of the 90% dose level (R90) and the 50% dose level (R50). Two-dimensional distal dose surfaces were calculated and the root mean square differences (RMSD), average range difference (ARD) and average distal dose degradation (ADD), the distance between the distal position of the 80% and 20% dose levels (R80- R20), were analyzed. Results: We found target coverage indices calculated by TOPAS to generally be around 1–2% lower than predicted by the analytical algorithm. Differences in R90 predicted by TOPAS and the planning system can be larger than currently applied range margins in proton therapy for small regions distal to the target volume. We estimate new site-specific range margins (R90) for analytical dose calculations considering total range uncertainties and uncertainties from dose calculation alone based on the RMSD. Our results demonstrate that a reduction of currently used uncertainty margins is feasible for liver, prostate and whole brain fields even without introducing MC dose calculations. Conclusion: Analytical dose calculation algorithms predict dose distributions within clinical limits for more homogeneous patients sites (liver, prostate, whole brain). However, we

  19. Systematic review of the incremental costs of interventions that increase immunization coverage.

    PubMed

    Ozawa, Sachiko; Yemeke, Tatenda T; Thompson, Kimberly M

    2018-05-10

    Achieving and maintaining high vaccination coverage requires investments, but the costs and effectiveness of interventions to increase coverage remain poorly characterized. We conducted a systematic review of the literature to identify peer-reviewed studies published in English that reported interventions aimed at increasing immunization coverage and the associated costs and effectiveness of the interventions. We found limited information in the literature, with many studies reporting effectiveness estimates, but not providing cost information. Using the available data, we developed a cost function to support future programmatic decisions about investments in interventions to increase immunization coverage for relatively low and high-income countries. The cost function estimates the non-vaccine cost per dose of interventions to increase absolute immunization coverage by one percent, through either campaigns or routine immunization. The cost per dose per percent increase in absolute coverage increased with higher baseline coverage, demonstrating increasing incremental costs required to reach higher coverage levels. Future studies should evaluate the performance of the cost function and add to the database of available evidence to better characterize heterogeneity in costs and generalizability of the cost function. Copyright © 2018. Published by Elsevier Ltd.

  20. Forecasted trends in vaccination coverage and correlations with socioeconomic factors: a global time-series analysis over 30 years.

    PubMed

    de Figueiredo, Alexandre; Johnston, Iain G; Smith, David M D; Agarwal, Sumeet; Larson, Heidi J; Jones, Nick S

    2016-10-01

    Incomplete immunisation coverage causes preventable illness and death in both developing and developed countries. Identification of factors that might modulate coverage could inform effective immunisation programmes and policies. We constructed a performance indicator that could quantitatively approximate measures of the susceptibility of immunisation programmes to coverage losses, with an aim to identify correlations between trends in vaccine coverage and socioeconomic factors. We undertook a data-driven time-series analysis to examine trends in coverage of diphtheria, tetanus, and pertussis (DTP) vaccination across 190 countries over the past 30 years. We grouped countries into six world regions according to WHO classifications. We used Gaussian process regression to forecast future coverage rates and provide a vaccine performance index: a summary measure of the strength of immunisation coverage in a country. Overall vaccine coverage increased in all six world regions between 1980 and 2010, with variation in volatility and trends. Our vaccine performance index identified that 53 countries had more than a 50% chance of missing the Global Vaccine Action Plan (GVAP) target of 90% worldwide coverage with three doses of DTP (DTP3) by 2015. These countries were mostly in sub-Saharan Africa and south Asia, but Austria and Ukraine also featured. Factors associated with DTP3 immunisation coverage varied by world region: personal income (Spearman's ρ=0·66, p=0·0011) and government health spending (0·66, p<0·0001) were informative of immunisation coverage in the Eastern Mediterranean between 1980 and 2010, whereas primary school completion was informative of coverage in Africa (0·56, p<0·0001) over the same period. The proportion of births attended by skilled health staff correlated significantly with immunisation coverage across many world regions. Our vaccine performance index highlighted countries at risk of failing to achieve the GVAP target of 90% coverage by

  1. Conformal and intensity modulated irradiation of head and neck cancer: the potential for improved target irradiation, salivary gland function, and quality of life.

    PubMed

    Eisbruch, A; Dawson, L A; Kim, H M; Bradford, C R; Terrell, J E; Chepeha, D B; Teknos, T N; Anzai, Y; Marsh, L H; Martel, M K; Ten Haken, R K; Wolf, G T; Ship, J A

    1999-01-01

    To develop techniques which facilitate sparing of the major salivary glands while adequately treating the targets in patients requiring comprehensive bilateral neck irradiation (RT). Conformal and static, multisegmental intensity modulated (IMRT) techniques have been developed. The salivary flow rates before and periodically after RT have been measured selectively from each major salivary gland and the residual flows correlated with glands' dose volume histograms. Subjective xerostomia questionnaires have been developed and validated. The pattern of local-regional recurrences has been examined using CT scans at the time of recurrence, transferring the recurrence volumes to the planning CT scans and regenerating the dose distributions at the recurrence sites. Target coverage and dose homogeneity in IMRT treatment plans were found to be significantly better than standard RT plans. Significant parotid gland sparing was achieved. The relationships among dose, irradiated volume and saliva flow rates from the parotid glands were characterized by dose and volume thresholds. A mean dose of 26 Gy was found to be the threshold for stimulated saliva. Subjective xerostomia was significantly reduced in patients irradiated with parotid sparing techniques, compared to patients with similar tumors treated with standard RT. The large majority of recurrences occurred inside high-risk targets. Tangible gains in salivary gland sparing and target coverage are being achieved and an improvement in some measures of quality of life is suggested by our findings. A mean parotid gland dose of < or = 26 Gy should be a planning objective if significant parotid function preservation is desired. The pattern of recurrence suggests that careful escalation of the dose to targets judged to be at highest risk may improve tumor control.

  2. SU-E-T-639: Proton Dose Calculation for Irregular Motion Using a Sliding Interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phillips, J; Gueorguiev, G; Grassberger, C

    2015-06-15

    Purpose: While many techniques exist to evaluate dose to regularly moving lung targets, there are few available to calculate dose at tumor positions not present in the 4DCT. We have previously developed a method that extrapolates an existing dose to a new tumor location. In this abstract, we present a novel technique that accounts for relative anatomical shifts at the chest wall interface. We also utilize this procedure to simulate breathing motion functions on a cohort of eleven patients. Amplitudes exceeding the original range of motion were used to evaluate coverage using several aperture and smearing beam settings. Methods: Themore » water-equivalent depth (WED) technique requires an initial dose and CT image at the corresponding tumor position. Each dose volume was converted from its Cartesian geometry into a beam-specific radiological depth space. The sliding chest wall interface was determined by converting the lung contour into this same space. Any dose proximal to the initial boundary of the warped lung contour was held fixed, while the remaining distal dose was moved in the direction of motion along the interface. Results: V95 coverage was computed for each patient using the updated algorithm. Incorporation of the sliding motion yielded large dose differences, with gamma pass rates as low as 69.7% (3mm, 3%) and V95 coverage differences up to 2.0%. Clinical coverage was maintained for most patients with 5 mm excess simulated breathing motion, and up to 10 mm of excess motion was tolerated for a subset of patients and beam settings. Conclusion: We have established a method to determine the maximum allowable excess breathing motion for a given plan on a patient-by-patient basis. By integrating a sliding chest wall interface into our dose calculation technique, we have analyzed the robustness of breathing patterns that differ during treatment from at the time of 4DCT acquisition.« less

  3. WE-G-BRE-03: Dose Painting by Numbers Using Targeted Gold Nanoparticles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Altundal, Y; Sajo, E; Korideck, H

    Purpose: Homogeneous dose enhancement in tumor cells of lung cancer patients treated with conventional dose of 60–66 Gy in five fractions is limited due to increased risk of toxicity to normal structures. Dose painting by numbers (DPBN) is the prescription of a non-uniform radiation dose distribution in the tumor for each voxel based on the intensity level of that voxel obtained from the tumor image. The purpose of this study is to show that DPBN using targeted gold nanoparticles (GNPs) could enhance conventional doses in the more resistant tumor areas. Methods: Cone beam computed tomography (CBCT) images of GNPs aftermore » intratumoral injection into human tumor were taken at 0, 48, 144 and 160 hours. The dose enhancement in the tumor voxels by secondary electrons from the GNPs was calculated based on analytical microdosimetry methods. The dose enhancement factor (DEF) is the ratio of the doses to the tumor with and without the presence of GNPs. The DEF was calculated for each voxel of the images based on the GNP concentration in the tumor sub-volumes using 6-MV photon spectra obtained using Monte Carlo simulations at 5 cm depth (10×10 cm2 field). Results: The results revealed DEF values of 1.05–2.38 for GNPs concentrations of 1–30 mg/g which corresponds to 12.60 – 28.56 Gy per fraction for delivering 12 Gy per fraction homogenously to lung tumor region. Conclusion: Our preliminary results verify that DPBN could be achieved using GNPs to enhance conventional doses to high risk tumor sub-volumes. In practice, DPBN using GNPs could be achieved due to diffusion of targeted GNPs sustainably released in-situ from radiotherapy biomaterials (e.g. fiducials) coated with polymer film containing the GNPs.« less

  4. Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ali, Imad, E-mail: iali@ouhsc.edu; Ahmad, Salahuddin

    2013-10-01

    To compare the doses calculated using the BrainLAB pencil beam (PB) and Monte Carlo (MC) algorithms for tumors located in various sites including the lung and evaluate quality assurance procedures required for the verification of the accuracy of dose calculation. The dose-calculation accuracy of PB and MC was also assessed quantitatively with measurement using ionization chamber and Gafchromic films placed in solid water and heterogeneous phantoms. The dose was calculated using PB convolution and MC algorithms in the iPlan treatment planning system from BrainLAB. The dose calculation was performed on the patient's computed tomography images with lesions in various treatmentmore » sites including 5 lungs, 5 prostates, 4 brains, 2 head and necks, and 2 paraspinal tissues. A combination of conventional, conformal, and intensity-modulated radiation therapy plans was used in dose calculation. The leaf sequence from intensity-modulated radiation therapy plans or beam shapes from conformal plans and monitor units and other planning parameters calculated by the PB were identical for calculating dose with MC. Heterogeneity correction was considered in both PB and MC dose calculations. Dose-volume parameters such as V95 (volume covered by 95% of prescription dose), dose distributions, and gamma analysis were used to evaluate the calculated dose by PB and MC. The measured doses by ionization chamber and EBT GAFCHROMIC film in solid water and heterogeneous phantoms were used to quantitatively asses the accuracy of dose calculated by PB and MC. The dose-volume histograms and dose distributions calculated by PB and MC in the brain, prostate, paraspinal, and head and neck were in good agreement with one another (within 5%) and provided acceptable planning target volume coverage. However, dose distributions of the patients with lung cancer had large discrepancies. For a plan optimized with PB, the dose coverage was shown as clinically acceptable, whereas in reality, the MC

  5. A Two-Phase Coverage-Enhancing Algorithm for Hybrid Wireless Sensor Networks

    PubMed Central

    Zhang, Qingguo; Fok, Mable P.

    2017-01-01

    Providing field coverage is a key task in many sensor network applications. In certain scenarios, the sensor field may have coverage holes due to random initial deployment of sensors; thus, the desired level of coverage cannot be achieved. A hybrid wireless sensor network is a cost-effective solution to this problem, which is achieved by repositioning a portion of the mobile sensors in the network to meet the network coverage requirement. This paper investigates how to redeploy mobile sensor nodes to improve network coverage in hybrid wireless sensor networks. We propose a two-phase coverage-enhancing algorithm for hybrid wireless sensor networks. In phase one, we use a differential evolution algorithm to compute the candidate’s target positions in the mobile sensor nodes that could potentially improve coverage. In the second phase, we use an optimization scheme on the candidate’s target positions calculated from phase one to reduce the accumulated potential moving distance of mobile sensors, such that the exact mobile sensor nodes that need to be moved as well as their final target positions can be determined. Experimental results show that the proposed algorithm provided significant improvement in terms of area coverage rate, average moving distance, area coverage–distance rate and the number of moved mobile sensors, when compare with other approaches. PMID:28075365

  6. Feasibility and robustness of dose painting by numbers in proton therapy with contour-driven plan optimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barragán, A. M., E-mail: ana.barragan@uclouvain.be; Differding, S.; Lee, J. A.

    Purpose: To prove the ability of protons to reproduce a dose gradient that matches a dose painting by numbers (DPBN) prescription in the presence of setup and range errors, by using contours and structure-based optimization in a commercial treatment planning system. Methods: For two patients with head and neck cancer, voxel-by-voxel prescription to the target volume (GTV{sub PET}) was calculated from {sup 18}FDG-PET images and approximated with several discrete prescription subcontours. Treatments were planned with proton pencil beam scanning. In order to determine the optimal plan parameters to approach the DPBN prescription, the effects of the scanning pattern, number ofmore » fields, number of subcontours, and use of range shifter were separately tested on each patient. Different constant scanning grids (i.e., spot spacing = Δx = Δy = 3.5, 4, and 5 mm) and uniform energy layer separation [4 and 5 mm WED (water equivalent distance)] were analyzed versus a dynamic and automatic selection of the spots grid. The number of subcontours was increased from 3 to 11 while the number of beams was set to 3, 5, or 7. Conventional PTV-based and robust clinical target volumes (CTV)-based optimization strategies were considered and their robustness against range and setup errors assessed. Because of the nonuniform prescription, ensuring robustness for coverage of GTV{sub PET} inevitably leads to overdosing, which was compared for both optimization schemes. Results: The optimal number of subcontours ranged from 5 to 7 for both patients. All considered scanning grids achieved accurate dose painting (1% average difference between the prescribed and planned doses). PTV-based plans led to nonrobust target coverage while robust-optimized plans improved it considerably (differences between worst-case CTV dose and the clinical constraint was up to 3 Gy for PTV-based plans and did not exceed 1 Gy for robust CTV-based plans). Also, only 15% of the points in the GTV{sub PET} (worst

  7. Impact of gastric filling on radiation dose delivered to gastroesophageal junction tumors.

    PubMed

    Bouchard, Myriam; McAleer, Mary Frances; Starkschall, George

    2010-05-01

    This study examined the impact of gastric filling variation on target coverage of gastroesophageal junction (GEJ) tumors in three-dimensional conformal radiation therapy (3DCRT), intensity-modulated radiation therapy (IMRT), or IMRT with simultaneous integrated boost (IMRT-SIB) plans. Eight patients previously receiving radiation therapy for esophageal cancer had computed tomography (CT) datasets acquired with full stomach (FS) and empty stomach (ES). We generated treatment plans for 3DCRT, IMRT, or IMRT-SIB for each patient on the ES-CT and on the FS-CT datasets. The 3DCRT and IMRT plans were planned to 50.4 Gy to the clinical target volume (CTV), and the same for IMRT-SIB plus 63.0 Gy to the gross tumor volume (GTV). Target coverage was evaluated using dose-volume histogram data for patient treatments simulated with ES-CT sets, assuming treatment on an FS for the entire course, and vice versa. FS volumes were a mean of 3.3 (range, 1.7-7.5) times greater than ES volumes. The volume of the GTV receiving >or=50.4 Gy (V(50.4Gy)) was 100% in all situations. The planning GTV V(63Gy) became suboptimal when gastric filling varied, regardless of whether simulation was done on the ES-CT or the FS-CT set. Stomach filling has a negligible impact on prescribed dose delivered to the GEJ GTV, using either 3DCRT or IMRT planning. Thus, local relapses are not likely to be related to variations in gastric filling. Dose escalation for GEJ tumors with IMRT-SIB may require gastric filling monitoring.

  8. Comparison of Dose Decrement from Intrafraction Motion for Prone and Supine Prostate Radiotherapy

    PubMed Central

    Olsen, Jeffrey; Parikh, Parag J; Watts, Michael; Noel, Camille E; Baker, Kenneth W; Santanam, Lakshmi; Michalski, Jeff M

    2012-01-01

    Background and Purpose Dose effects of intrafraction motion during prone prostate radiotherapy are unknown. We compared prone and supine treatment using real-time tracking data to model dose coverage. Material and Methods Electromagnetic tracking data was analyzed for 10 patients treated prone, and 15 treated supine, with IMRT for localized prostate cancer. Plans were generated using 0, 3, and 5 mm PTV expansions. Manual beam-hold interventions were applied to reposition the patient when translations exceeded a predetermined threshold. A custom software application (SWIFTER) used intrafraction tracking data acquired during beam-on to model delivered prostate dose, by applying rigid body transformations to the prostate structure contoured at simulation within the planned dose cloud. The delivered minimum prostate dose as a percentage of planned dose (Dmin%), and prostate volume covered by the prescription dose as a percentage of the planned volume (VRx%) were compared for prone and supine treatment. Results Dmin% was reduced for prone treatment for 0 (p=0.02) and 3 mm (p=0.03) PTV margins. VRx% was reduced for prone treatment only for 0 mm margins (p=0.002). No significant differences were found using 5 mm margins. Conclusions Intrafraction motion has a greater impact on target coverage for prone compared to supine prostate radiotherapy. PTV margins of 3 mm or less correlate with a significant decrease in delivered dose for prone treatment. PMID:22809590

  9. Comparison of dose decrement from intrafraction motion for prone and supine prostate radiotherapy.

    PubMed

    Olsen, Jeffrey R; Parikh, Parag J; Watts, Michael; Noel, Camille E; Baker, Kenneth W; Santanam, Lakshmi; Michalski, Jeff M

    2012-08-01

    Dose effects of intrafraction motion during prone prostate radiotherapy are unknown. We compared prone and supine treatment using real-time tracking data to model dose coverage. Electromagnetic tracking data were analyzed for 10 patients treated prone, and 15 treated supine, with IMRT for localized prostate cancer. Plans were generated using 0 mm, 3 mm, and 5mm PTV expansions. Manual beam-hold interventions were applied to reposition the patient when translations exceeded a predetermined threshold. A custom software application (SWIFTER) used intrafraction tracking data acquired during beam-on model delivered prostate dose, by applying rigid body transformations to the prostate structure contoured at simulation within the planned dose cloud. The delivered minimum prostate dose as a percentage of planned dose (Dmin%), and prostate volume covered by the prescription dose as a percentage of the planned volume (VRx%) were compared for prone and supine treatment. Dmin% was reduced for prone treatment for 0 (p=0.02) and 3 mm (p=0.03) PTV margins. VRx% was reduced for prone treatment only for 0mm margins (p=0.002). No significant differences were found using 5 mm margins. Intrafraction motion has a greater impact on target coverage for prone compared to supine prostate radiotherapy. PTV margins of 3 mm or less correlate with a significant decrease in delivered dose for prone treatment. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  10. Low-dose radiation potentiates the therapeutic efficacy of folate receptor-targeted hapten therapy.

    PubMed

    Sega, Emanuela I; Lu, Yingjuan; Ringor, Michael; Leamon, Christopher P; Low, Philip S

    2008-06-01

    Human cancers frequently overexpress a high-affinity cell-surface receptor for the vitamin folic acid. Highly immunogenic haptens can be targeted to folate receptor-expressing cell surfaces by administration of folate-hapten conjugates, rendering the decorated tumor cell surfaces more recognizable by the immune system. Treatment of antihapten-immunized mice with folate-hapten constructs results in elimination of moderately sized tumors by the immune system. However, when subcutaneous tumors exceed 300 mm(3) before initiation of therapy, antitumor activity is significantly decreased. In an effort to enhance the efficacy of folate-targeted hapten immunotherapy (FTHI) against large tumors, we explored the combination of targeted hapten immunotherapy with low-dose radiotherapy. Mice bearing 300-mm(3) subcutaneous tumors were treated concurrently with FTHI (500 nmol/kg of folate conjugated to fluorescein isothiocyanate, 20,000 U/dose of interleukin 2, and 25,000 U/dose of interferon alpha) and low-dose radiotherapy (3 Gy/dose focused directly on the desired tumor mass). The efficacy of therapy was evaluated by measuring tumor volume. Tumor growth analyses show that radiotherapy synergizes with FTHI in antihapten-immunized mice, thereby allowing for cures of animals bearing tumors greater than 300 mm(3). More importantly, nonirradiated distal tumor masses in animals containing locally irradiated tumors also showed improved response to hapten immunotherapy, suggesting that not all tumor lesions must be identified and irradiated to benefit from the combination therapy. These results suggest that simultaneous treatment with FTHI and radiation therapy can enhance systemic antitumor activity in tumor-bearing mice.

  11. Estimation of child vaccination coverage at state and national levels in India

    PubMed Central

    Gupta, Satish; Kumar, Rakesh; Haldar, Pradeep; Sethi, Raman; Bahl, Sunil

    2016-01-01

    Abstract Objective To review the data, for 1999–2013, on state-level child vaccination coverage in India and provide estimates of coverage at state and national levels. Methods We collated data from administrative reports, population-based surveys and other sources and used them to produce annual estimates of vaccination coverage. We investigated bacille Calmette–Guérin vaccine, the first and third doses of vaccine against diphtheria, tetanus and pertussis, the third dose of oral polio vaccine and the first dose of vaccine against measles. We obtained relevant data covering the period 1999–2013 for each of 16 states and territories and the period 2001–2013 for the state of Jharkhand – which was only created in 2000. We aggregated the resultant state-level estimates, using a population-weighted approach, to give national values. Findings For each of the vaccinations we investigated, about half of the 253 estimates of annual coverage at state level that we produced were based on survey results. The rest were based on interpolation between – or extrapolation from – so-called anchor points or, more rarely, on administrative data. Our national estimates indicated that, for each of the vaccines we investigated, coverage gradually increased between 1999 and 2010 but then levelled off. Conclusion The delivery of routine vaccination services to Indian children appears to have improved between 1999 and 2013. There remains considerable scope to improve the recording and reporting of childhood vaccination coverage in India and regular systematic reviews of the coverage data are recommended. PMID:27843162

  12. SU-E-T-632: Preliminary Study On Treating Nose Skin Using Energy and Intensity Modulated Electron Beams with Monte Carlo Based Dose Calculations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jin, L; Eldib, A; Li, J

    Purpose: Uneven nose surfaces and air cavities underneath and the use of bolus present complexity and dose uncertainty when using a single electron energy beam to plan treatments of nose skin with a pencil beam-based planning system. This work demonstrates more accurate dose calculation and more optimal planning using energy and intensity modulated electron radiotherapy (MERT) delivered with a pMLC. Methods: An in-house developed Monte Carlo (MC)-based dose calculation/optimization planning system was employed for treatment planning. Phase space data (6, 9, 12 and 15 MeV) were used as an input source for MC dose calculations for the linac. To reducemore » the scatter-caused penumbra, a short SSD (61 cm) was used. Our previous work demonstrates good agreement in percentage depth dose and off-axis dose between calculations and film measurement for various field sizes. A MERT plan was generated for treating the nose skin using a patient geometry and a dose volume histogram (DVH) was obtained. The work also shows the comparison of 2D dose distributions between a clinically used conventional single electron energy plan and the MERT plan. Results: The MERT plan resulted in improved target dose coverage as compared to the conventional plan, which demonstrated a target dose deficit at the field edge. The conventional plan showed higher dose normal tissue irradiation underneath the nose skin while the MERT plan resulted in improved conformity and thus reduces normal tissue dose. Conclusion: This preliminary work illustrates that MC-based MERT planning is a promising technique in treating nose skin, not only providing more accurate dose calculation, but also offering an improved target dose coverage and conformity. In addition, this technique may eliminate the necessity of bolus, which often produces dose delivery uncertainty due to the air gaps that may exist between the bolus and skin.« less

  13. Use of PET and Other Functional Imaging to Guide Target Delineation in Radiation Oncology.

    PubMed

    Verma, Vivek; Choi, J Isabelle; Sawant, Amit; Gullapalli, Rao P; Chen, Wengen; Alavi, Abass; Simone, Charles B

    2018-06-01

    Molecular and functional imaging is increasingly being used to guide radiotherapy (RT) management and target delineation. This review summarizes existing data in several disease sites of various functional imaging modalities, chiefly positron emission tomography/computed tomography (PET/CT), with respect to RT target definition and management. For gliomas, differentiation between postoperative changes and viable tumor is discussed, as well as focal dose escalation and reirradiation. Head and neck neoplasms may also benefit from precise PET/CT-based target delineation, especially for cancers of unknown primary; focal dose escalation is also described. In lung cancer, PET/CT can influence coverage of tumor volumes, dose escalation, and adaptive management. For cervical cancer, PET/CT as an adjunct to magnetic resonance imaging planning is discussed, as are dose escalation and delineation of avoidance targets such as the bone marrow. The emerging role of choline-based PET for prostate cancer and its impact on dose escalation is also described. Lastly, given the essential role of PET/CT for target definition in lymphoma, phase III trials of PET-directed management are reviewed, along with novel imaging modalities. Taken together, molecular and functional imaging approaches offer a major step to individualize radiotherapeutic care going forward. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Comparison of Monte Carlo and analytical dose computations for intensity modulated proton therapy

    NASA Astrophysics Data System (ADS)

    Yepes, Pablo; Adair, Antony; Grosshans, David; Mirkovic, Dragan; Poenisch, Falk; Titt, Uwe; Wang, Qianxia; Mohan, Radhe

    2018-02-01

    To evaluate the effect of approximations in clinical analytical calculations performed by a treatment planning system (TPS) on dosimetric indices in intensity modulated proton therapy. TPS calculated dose distributions were compared with dose distributions as estimated by Monte Carlo (MC) simulations, calculated with the fast dose calculator (FDC) a system previously benchmarked to full MC. This study analyzed a total of 525 patients for four treatment sites (brain, head-and-neck, thorax and prostate). Dosimetric indices (D02, D05, D20, D50, D95, D98, EUD and Mean Dose) and a gamma-index analysis were utilized to evaluate the differences. The gamma-index passing rates for a 3%/3 mm criterion for voxels with a dose larger than 10% of the maximum dose had a median larger than 98% for all sites. The median difference for all dosimetric indices for target volumes was less than 2% for all cases. However, differences for target volumes as large as 10% were found for 2% of the thoracic patients. For organs at risk (OARs), the median absolute dose difference was smaller than 2 Gy for all indices and cohorts. However, absolute dose differences as large as 10 Gy were found for some small volume organs in brain and head-and-neck patients. This analysis concludes that for a fraction of the patients studied, TPS may overestimate the dose in the target by as much as 10%, while for some OARs the dose could be underestimated by as much as 10 Gy. Monte Carlo dose calculations may be needed to ensure more accurate dose computations to improve target coverage and sparing of OARs in proton therapy.

  15. Assessing the Clinical Impact of Approximations in Analytical Dose Calculations for Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schuemann, Jan, E-mail: jschuemann@mgh.harvard.edu; Giantsoudi, Drosoula; Grassberger, Clemens

    2015-08-01

    Purpose: To assess the impact of approximations in current analytical dose calculation methods (ADCs) on tumor control probability (TCP) in proton therapy. Methods: Dose distributions planned with ADC were compared with delivered dose distributions as determined by Monte Carlo simulations. A total of 50 patients were investigated in this analysis with 10 patients per site for 5 treatment sites (head and neck, lung, breast, prostate, liver). Differences were evaluated using dosimetric indices based on a dose-volume histogram analysis, a γ-index analysis, and estimations of TCP. Results: We found that ADC overestimated the target doses on average by 1% to 2%more » for all patients considered. The mean dose, D95, D50, and D02 (the dose value covering 95%, 50% and 2% of the target volume, respectively) were predicted within 5% of the delivered dose. The γ-index passing rate for target volumes was above 96% for a 3%/3 mm criterion. Differences in TCP were up to 2%, 2.5%, 6%, 6.5%, and 11% for liver and breast, prostate, head and neck, and lung patients, respectively. Differences in normal tissue complication probabilities for bladder and anterior rectum of prostate patients were less than 3%. Conclusion: Our results indicate that current dose calculation algorithms lead to underdosage of the target by as much as 5%, resulting in differences in TCP of up to 11%. To ensure full target coverage, advanced dose calculation methods like Monte Carlo simulations may be necessary in proton therapy. Monte Carlo simulations may also be required to avoid biases resulting from systematic discrepancies in calculated dose distributions for clinical trials comparing proton therapy with conventional radiation therapy.« less

  16. Interactive dose shaping part 2: proof of concept study for six prostate patients

    PubMed Central

    Ph Kamerling, Cornelis; Ziegenhein, Peter; Sterzing, Florian; Oelfke, Uwe

    2016-01-01

    Abstract Recently we introduced interactive dose shaping (IDS) as a new IMRT planning strategy. This planning concept is based on a hierarchical sequence of local dose modification and recovery operations. The purpose of this work is to provide a feasibility study for the IDS planning strategy based on a small set of six prostate patients. The IDS planning paradigm aims to perform interactive local dose adaptations of an IMRT plan without compromising already established valuable dose features in real-time. Various IDS tools were developed in our in-house treatment planning software Dynaplan and were utilized to create IMRT treatment plans for six patients with an adeno-carcinoma of the prostate. The sequenced IDS treatment plans were compared to conventionally optimized clinically approved plans (9 beams, co-planar). For each patient, several IDS plans were created, with different trade-offs between organ sparing and target coverage. The reference dose distributions were imported into Dynaplan. For each patient, the IDS treatment plan with a similar or better trade-off between target coverage and OAR sparing was selected for plan evaluation, guided by a physician. For this initial study we were able to generate treatment plans for prostate geometries in 15–45 min. Individual local dose adaptations could be performed in less than one second. The average differences compared to the reference plans were for the mean dose: 0.0 Gy (boost) and 1.2 Gy (PTV), for \\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}${{D}_{98\\%}}:-1.1$ \\end{document}D98%:−1.1 Gy and for \\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength

  17. Parental Delay or Refusal of Vaccine Doses, Childhood Vaccination Coverage at 24 Months of Age, and the Health Belief Model

    PubMed Central

    Smith, Philip J.; Humiston, Sharon G.; Marcuse, Edgar K.; Zhao, Zhen; Dorell, Christina G.; Howes, Cynthia; Hibbs, Beth

    2011-01-01

    Objective We evaluated the association between parents' beliefs about vaccines, their decision to delay or refuse vaccines for their children, and vaccination coverage of children at aged 24 months. Methods We used data from 11,206 parents of children aged 24–35 months at the time of the 2009 National Immunization Survey interview and determined their vaccination status at aged 24 months. Data included parents' reports of delay and/or refusal of vaccine doses, psychosocial factors suggested by the Health Belief Model, and provider-reported up-to-date vaccination status. Results In 2009, approximately 60.2% of parents with children aged 24–35 months neither delayed nor refused vaccines, 25.8% only delayed, 8.2% only refused, and 5.8% both delayed and refused vaccines. Compared with parents who neither delayed nor refused vaccines, parents who delayed and refused vaccines were significantly less likely to believe that vaccines are necessary to protect the health of children (70.1% vs. 96.2%), that their child might get a disease if they aren't vaccinated (71.0% vs. 90.0%), and that vaccines are safe (50.4% vs. 84.9%). Children of parents who delayed and refused also had significantly lower vaccination coverage for nine of the 10 recommended childhood vaccines including diphtheria-tetanus-acellular pertussis (65.3% vs. 85.2%), polio (76.9% vs. 93.8%), and measles-mumps-rubella (68.4% vs. 92.5%). After adjusting for sociodemographic differences, we found that parents who were less likely to agree that vaccines are necessary to protect the health of children, to believe that their child might get a disease if they aren't vaccinated, or to believe that vaccines are safe had significantly lower coverage for all 10 childhood vaccines. Conclusions Parents who delayed and refused vaccine doses were more likely to have vaccine safety concerns and perceive fewer benefits associated with vaccines. Guidelines published by the American Academy of Pediatrics may assist

  18. Estimation of Nationwide Vaccination Coverage and Comparison of Interview and Telephone Survey Methodology for Estimating Vaccination Status

    PubMed Central

    Park, Boyoung; Lee, Yeon-Kyeng; Cho, Lisa Y.; Go, Un Yeong; Yang, Jae Jeong; Ma, Seung Hyun; Choi, Bo-Youl; Lee, Moo-Sik; Lee, Jin-Seok; Choi, Eun Hwa; Lee, Hoan Jong

    2011-01-01

    This study compared interview and telephone surveys to select the better method for regularly estimating nationwide vaccination coverage rates in Korea. Interview surveys using multi-stage cluster sampling and telephone surveys using stratified random sampling were conducted. Nationwide coverage rates were estimated in subjects with vaccination cards in the interview survey. The interview survey relative to the telephone survey showed a higher response rate, lower missing rate, higher validity and a less difference in vaccination coverage rates between card owners and non-owners. Primary vaccination coverage rate was greater than 90% except for the fourth dose of DTaP (diphtheria/tetanus/pertussis), the third dose of polio, and the third dose of Japanese B encephalitis (JBE). The DTaP4: Polio3: MMR1 fully vaccination rate was 62.0% and BCG1:HepB3:DTaP4:Polio3:MMR1 was 59.5%. For age-appropriate vaccination, the coverage rate was 50%-80%. We concluded that the interview survey was better than the telephone survey. These results can be applied to countries with incomplete registry and decreasing rates of landline telephone coverage due to increased cell phone usage and countries. Among mandatory vaccines, efforts to increase vaccination rate for the fourth dose of DTaP, the third dose of polio, JBE and regular vaccinations at recommended periods should be conducted in Korea. PMID:21655054

  19. Radiation Dose-Volume Effects and the Penile Bulb

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roach, Mack, E-mail: mroach@radonc.ucsf.ed; Nam, Jiho; Gagliardi, Giovanna

    2010-03-01

    The dose, volume, and clinical outcome data for penile bulb are reviewed for patients treated with external-beam radiotherapy. Most, but not all, studies find an association between impotence and dosimetric parameters (e.g., threshold doses) and clinical factors (e.g., age, comorbid diseases). According to the data available, it is prudent to keep the mean dose to 95% of the penile bulb volume to <50 Gy. It may also be prudent to limit the D70 and D90 to 70 Gy and 50 Gy, respectively, but coverage of the planning target volume should not be compromised. It is acknowledged that the penile bulbmore » may not be the critical component of the erectile apparatus, but it seems to be a surrogate for yet to be determined structure(s) critical for erectile function for at least some techniques.« less

  20. Low-Dose Radiation Potentiates the Therapeutic Efficacy of Folate Receptor-Targeted Hapten Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sega, Emanuela I.; Lu Yingjuan; Ringor, Michael

    2008-06-01

    Purpose: Human cancers frequently overexpress a high-affinity cell-surface receptor for the vitamin folic acid. Highly immunogenic haptens can be targeted to folate receptor-expressing cell surfaces by administration of folate-hapten conjugates, rendering the decorated tumor cell surfaces more recognizable by the immune system. Treatment of antihapten-immunized mice with folate-hapten constructs results in elimination of moderately sized tumors by the immune system. However, when subcutaneous tumors exceed 300 mm{sup 3} before initiation of therapy, antitumor activity is significantly decreased. In an effort to enhance the efficacy of folate-targeted hapten immunotherapy (FTHI) against large tumors, we explored the combination of targeted hapten immunotherapymore » with low-dose radiotherapy. Methods and Materials: Mice bearing 300-mm{sup 3} subcutaneous tumors were treated concurrently with FTHI (500 nmol/kg of folate conjugated to fluorescein isothiocyanate, 20,000 U/dose of interleukin 2, and 25,000 U/dose of interferon {alpha}) and low-dose radiotherapy (3 Gy/dose focused directly on the desired tumor mass). The efficacy of therapy was evaluated by measuring tumor volume. Results: Tumor growth analyses show that radiotherapy synergizes with FTHI in antihapten-immunized mice, thereby allowing for cures of animals bearing tumors greater than 300 mm{sup 3}. More importantly, nonirradiated distal tumor masses in animals containing locally irradiated tumors also showed improved response to hapten immunotherapy, suggesting that not all tumor lesions must be identified and irradiated to benefit from the combination therapy. Conclusions: These results suggest that simultaneous treatment with FTHI and radiation therapy can enhance systemic antitumor activity in tumor-bearing mice.« less

  1. SU-E-T-278: Dose Conformity Index for the Target in a Multitarget Environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harikrishnaperumal, Sudahar

    2015-06-15

    Purpose: The existing conformity index formulations are failing when multiple targets present outside the target of interest with same or different dose prescriptions. In the present study a novel methodology is introduced to solve this issue. Methods: The conformity index used by Nakamura et al (Int J Radiat Oncol Biol Phys 2001; 51(5):1313–1319) is taken as the base for this methodology. In this proposal, the prescription isodose volume (PIV) which normally includes the normal tissue and other target regions is restricted as PIV in annular regions of different thickness around the target of interest. The graphical line plotted between themore » thickness of annular region and the corresponding conformity index, will increase in the beginning and will reach a flat region, then it will increase again. The second increase in the conformity index depends basically on the distance between the targets, dose prescriptions, and size of the targets. The conformity index in the flat region should be the conformity index of the target of interest. This methodology was validated on dual target environment on a skull phantom in Multiplan planning system (Accuray Inc. Sunnyvale, USA) Results: When the surrounding target’s (sphere) size is changed from 1.5cm to 6cm diameter, the conformity index of the target of interest (3cm diameter) changed from 1.09 to 1.25. When the distance between the targets changed from 7.5cm to 2.5cm, the conformity index changed from 1.10 to 1.17. Similarly, when the prescribed dose changed from 25Gy to 50Gy the conformity index changed from 1.09 to 1.42. These values were above 2.0 when Nakamura et al formula was used. Conclusion: The proposed conformity index methodology eliminates the influence of surrounding targets to a greater extend. However, the limitations of this method should be studied further. Application of this method in clinical situations is the future scope.« less

  2. Intensity Modulated Radiotherapy Improves Target Coverage and Parotid Gland Sparing When Delivering Total Mucosal Irradiation in Patients With Squamous Cell Carcinoma of Head and Neck of Unknown Primary Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhide, Shreerang; Clark, Catherine; Harrington, Kevin

    2007-10-01

    Head and neck squamous cell carcinoma with occult primary site represents a controversial clinical problem. Conventional total mucosal irradiation (TMI) maximizes local control, but at the expense of xerostomia. IMRT has been shown to spare salivary tissue in head and cancer patients. This study has been performed to investigate the potential of IMRT to perform nodal and TMI and also allow parotid gland sparing in this patient group. Conventional radiotherapy (CRT) and IMRT plans were produced for six patients to treat the ipsilateral (involved) post-operative neck (PTV1) and the un-operated contralateral neck and mucosal axis (PTV2). Plans were produced withmore » and without the inclusion of nasopharynx in the PTV2. The potential to improve target coverage and spare the parotid glands was investigated for the IMRT plans. There was no significant difference in the mean doses to the PTV1 using CRT and IMRT (59.7 and 60.0 respectively, p = 0.5). The maximum doses to PTV1 and PTV2 were lower for the IMRT technique as compared to CRT (P = 0.008 and P < 0.0001), respectively, and the minimum doses to PTV1 and PTV2 were significantly higher for IMRT as compared to CRT (P = 0.001 and P = 0.001), respectively, illustrating better dose homogeneity with IMRT. The mean dose to the parotid gland contralateral to PTV1 was significantly lower for IMRT (23.21 {+-} 0.7) as compared to CRT (50.5 {+-} 5.8) (P < 0.0001). There was a significant difference in parotid dose between plans with and without the inclusion of the nasopharynx. IMRT offers improved dose homogeneity in PTV1 and PTV2 and allows for parotid sparing.« less

  3. Non-Targeted Effects and the Dose Response for Heavy Ion Tumorigenesis

    NASA Technical Reports Server (NTRS)

    Chappelli, Lori J.; Cucinotta, Francis A.

    2010-01-01

    BACKGROUND: There is no human epidemiology data available to estimate the heavy ion cancer risks experienced by astronauts in space. Studies of tumor induction in mice are a necessary step to estimate risks to astronauts. Previous experimental data can be better utilized to model dose response for heavy ion tumorigenesis and plan future low dose studies. DOSE RESPONSE MODELS: The Harderian Gland data of Alpen et al.[1-3] was re-analyzed [4] using non-linear least square regression. The data set measured the induction of Harderian gland tumors in mice by high-energy protons, helium, neon, iron, niobium and lanthanum with LET s ranging from 0.4 to 950 keV/micron. We were able to strengthen the individual ion models by combining data for all ions into a model that relates both radiation dose and LET for the ion to tumor prevalence. We compared models based on Targeted Effects (TE) to one motivated by Non-targeted Effects (NTE) that included a bystander term that increased tumor induction at low doses non-linearly. When comparing fitted models to the experimental data, we considered the adjusted R2, the Akaike Information Criteria (AIC), and the Bayesian Information Criteria (BIC) to test for Goodness of fit.In the adjusted R2test, the model with the highest R2values provides a better fit to the available data. In the AIC and BIC tests, the model with the smaller values of the summary value provides the better fit. The non-linear NTE models fit the combined data better than the TE models that are linear at low doses. We evaluated the differences in the relative biological effectiveness (RBE) and found the NTE model provides a higher RBE at low dose compared to the TE model. POWER ANALYSIS: The final NTE model estimates were used to simulate example data to consider the design of new experiments to detect NTE at low dose for validation. Power and sample sizes were calculated for a variety of radiation qualities including some not considered in the Harderian Gland data

  4. Human papillomavirus (HPV) vaccine coverage achievements in low and middle-income countries 2007-2016.

    PubMed

    Gallagher, Katherine E; Howard, Natasha; Kabakama, Severin; Mounier-Jack, Sandra; Burchett, Helen E D; LaMontagne, D Scott; Watson-Jones, Deborah

    2017-12-01

    Since 2007, HPV vaccine has been available to low and middle income countries (LAMIC) for small-scale 'demonstration projects', or national programmes. We analysed coverage achieved in HPV vaccine demonstration projects and national programmes that had completed at least 6 months of implementation between January 2007-2016. A mapping exercise identified 45 LAMICs with HPV vaccine delivery experience. Estimates of coverage and factors influencing coverage were obtained from 56 key informant interviews, a systematic published literature search of 5 databases that identified 61 relevant full texts and 188 solicited unpublished documents, including coverage surveys. Coverage achievements were analysed descriptively against country or project/programme characteristics. Heterogeneity in data, funder requirements, and project/programme design precluded multivariate analysis. Estimates of uptake, schedule completion rates and/or final dose coverage were available from 41 of 45 LAMICs included in the study. Only 17 estimates from 13 countries were from coverage surveys, most were administrative data. Final dose coverage estimates were all over 50% with most between 70% and 90%, and showed no trend over time. The majority of delivery strategies included schools as a vaccination venue. In countries with school enrolment rates below 90%, inclusion of strategies to reach out-of-school girls contributed to obtaining high coverage compared to school-only strategies. There was no correlation between final dose coverage and estimated recurrent financial costs of delivery from cost analyses. Coverage achieved during joint delivery of HPV vaccine combined with another intervention was variable with little/no evaluation of the correlates of success. This is the most comprehensive descriptive analysis of HPV vaccine coverage in LAMICs to date. It is possible to deliver HPV vaccine with excellent coverage in LAMICs. Further good quality data are needed from health facility based

  5. Dose-finding designs for trials of molecularly targeted agents and immunotherapies

    PubMed Central

    Chiuzan, Cody; Shtaynberger, Jonathan; Manji, Gulam A.; Duong, Jimmy K.; Schwartz, Gary K.; Ivanova, Anastasia; Lee, Shing M.

    2017-01-01

    Recently, there has been a surge of early phase trials of molecularly targeted agents (MTAs) and immunotherapies. These new therapies have different toxicity profiles compared to cytotoxic therapies. MTAs can benefit from new trial designs that allow inclusion of low-grade toxicities, late-onset toxicities, addition of an efficacy endpoint, and flexibility in the specification of a target toxicity probability. To study the degree of adoption of these methods, we conducted a Web of Science search of articles published between 2008 and 2014 that describe phase 1 oncology trials. Trials were categorized based on the dose-finding design used and the type of drug studied. Out of 1,712 dose-finding trials that met our criteria, 1,591 (92.9%) utilized a rule-based design, and 92 (5.4%; range 2.3% in 2009 to 9.7% in 2014) utilized a model-based or novel design. Over half of the trials tested an MTA or immunotherapy. Among the MTA and immunotherapy trials, 5.8% used model-based methods, compared to 3.9% and 8.3% of the chemotherapy or radiotherapy trials, respectively. While the percentage of trials using novel dose-finding designs has tripled since 2007, only 7.1% of trials use novel designs. PMID:28166468

  6. SU-E-T-215: Interactive Dose Shaping: Proof of Concept Study for Six Prostate Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kamerling, CP; German Cancer Research Center; Ziegenhein, P

    Purpose: To provide a proof of concept study for IMRT treatment planning through interactive dose shaping (IDS) by utilising the respective tools to create IMRT treatment plans for six prostate patients. Methods: The IDS planning paradigm aims to perform interactive local dose adaptations of an IMRT plan without compromising already established valuable dose features in real-time. Various IDS tools are available in our in-house treatment planning software Dynaplan and were utilised to create IMRT treatment plans for six patients with an adeno-carcinoma of the prostate. The sequenced IDS treatment plans were compared to conventionally optimised clinically approved plans (9 beams,more » co-planar). The starting point consisted of open fields. The IDS tools were utilised to sculpt dose out of the rectum and bladder. For each patient, several IDS plans were created, with different trade-offs between organ sparing and target coverage. The reference dose distributions were imported into Dynaplan. For each patient, the IDS treatment plan with a similar or better trade-off between target coverage and OAR sparing was selected for plan evaluation, guided by a physician. Pencil beam dose calculation was performed on a grid with a voxel size of 1.95×1.95×2.0 mm{sup 3}. D98%, D2%, mean dose and dose-volume indicators as specified by Quantec were calculated for plan evaluation. Results: It was possible to utilise the software prototype to generate treatment plans for prostate patient geometries in 15–45 minutes. Individual local dose adaptations could be performed in less than one second. The average differences compared to the reference plans were for the mean dose: 0.0 Gy (boost) and 1.2 Gy (CTV), for D98%: −1.1 Gy and for D2%: 1.1 Gy (both target volumes). The dose-volume quality indicators were well below the Quantec constraints. Conclusion: Real-time treatment planning utilising IDS is feasible and has the potential to be implemented clinically. Research at The

  7. Socio-economic determinants and inequities in coverage and timeliness of early childhood immunisation in rural Ghana.

    PubMed

    Gram, Lu; Soremekun, Seyi; ten Asbroek, Augustinus; Manu, Alexander; O'Leary, Maureen; Hill, Zelee; Danso, Samuel; Amenga-Etego, Seeba; Owusu-Agyei, Seth; Kirkwood, Betty R

    2014-07-01

    To assess the extent of socio-economic inequity in coverage and timeliness of key childhood immunisations in Ghana. Secondary analysis of vaccination card data collected from babies born between January 2008 and January 2010 who were registered in the surveillance system supporting the ObaapaVita and Newhints Trials was carried out. 20 251 babies had 6 weeks' follow-up, 16 652 had 26 weeks' follow-up, and 5568 had 1 year's follow-up. We performed a descriptive analysis of coverage and timeliness of vaccinations by indicators for urban/rural status, wealth and educational attainment. The association of coverage with socio-economic indicators was tested using a chi-square-test and the association with timeliness using Cox regression. Overall coverage at 1 year of age was high (>95%) for Bacillus Calmette-Guérin (BCG), all three pentavalent diphtheria-pertussis-tetanus-haemophilus influenzae B-hepatitis B (DPTHH) doses and all polio doses except polio at birth (63%). Coverage against measles and yellow fever was 85%. Median delay for BCG was 1.7 weeks. For polio at birth, the median delay was 5 days; all other vaccine doses had median delays of 2-4 weeks. We found substantial health inequity across all socio-economic indicators for all vaccines in terms of timeliness, but not coverage at 1 year. For example, for the last DPTHH dose, the proportion of children delayed more than 8 weeks were 27% for urban children and 31% for rural children (P < 0.001), 21% in the wealthiest quintile and 41% in the poorest quintile (P < 0.001), and 9% in the most educated group and 39% in the least educated group (P < 0.001). However, 1-year coverage of the same dose remained above 90% for all levels of all socio-economic indicators. Ghana has substantial health inequity across urban/rural, socio-economic and educational divides. While overall coverage was high, most vaccines suffered from poor timeliness. We suggest that countries achieving high coverage should include timeliness

  8. Stereotactic radiotherapy of intrapulmonary lesions: comparison of different dose calculation algorithms for Oncentra MasterPlan®.

    PubMed

    Troeller, Almut; Garny, Sylvia; Pachmann, Sophia; Kantz, Steffi; Gerum, Sabine; Manapov, Farkhad; Ganswindt, Ute; Belka, Claus; Söhn, Matthias

    2015-02-22

    The use of high accuracy dose calculation algorithms, such as Monte Carlo (MC) and Collapsed Cone (CC) determine dose in inhomogeneous tissue more accurately than pencil beam (PB) algorithms. However, prescription protocols based on clinical experience with PB are often used for treatment plans calculated with CC. This may lead to treatment plans with changes in field size (FS) and changes in dose to organs at risk (OAR), especially for small tumor volumes in lung tissue treated with SABR. We re-evaluated 17 3D-conformal treatment plans for small intrapulmonary lesions with a prescription of 60 Gy in fractions of 7.5 Gy to the 80% isodose. All treatment plans were initially calculated in Oncentra MasterPlan® using a PB algorithm and recalculated with CC (CCre-calc). Furthermore, a CC-based plan with coverage similar to the PB plan (CCcov) and a CC plan with relaxed coverage criteria (CCclin), were created. The plans were analyzed in terms of Dmean, Dmin, Dmax and coverage for GTV, PTV and ITV. Changes in mean lung dose (MLD), V10Gy and V20Gy were evaluated for the lungs. The re-planned CC plans were compared to the original PB plans regarding changes in total monitor units (MU) and average FS. When PB plans were recalculated with CC, the average V60Gy of GTV, ITV and PTV decreased by 13.2%, 19.9% and 41.4%, respectively. Average Dmean decreased by 9% (GTV), 11.6% (ITV) and 14.2% (PTV). Dmin decreased by 18.5% (GTV), 21.3% (ITV) and 17.5% (PTV). Dmax declined by 7.5%. PTV coverage correlated with PTV volume (p < 0.001). MLD, V10Gy, and V20Gy were significantly reduced in the CC plans. Both, CCcov and CCclin had significantly increased MUs and FS compared to PB. Recalculation of PB plans for small lung lesions with CC showed a strong decline in dose and coverage in GTV, ITV and PTV, and declined dose in the lung. Thus, switching from a PB algorithm to CC, while aiming to obtain similar target coverage, can be associated with application of more MU and extension of

  9. Dosimetric evaluation of high-dose-rate interstitial brachytherapy boost treatments for localized prostate cancer.

    PubMed

    Fröhlich, Georgina; Agoston, Péter; Lövey, József; Somogyi, András; Fodor, János; Polgár, Csaba; Major, Tibor

    2010-07-01

    To quantitatively evaluate the dose distributions of high-dose-rate (HDR) prostate implants regarding target coverage, dose homogeneity, and dose to organs at risk. Treatment plans of 174 implants were evaluated using cumulative dose-volume histograms (DVHs). The planning was based on transrectal ultrasound (US) imaging, and the prescribed dose (100%) was 10 Gy. The tolerance doses to rectum and urethra were 80% and 120%, respectively. Dose-volume parameters for target (V90, V100, V150, V200, D90, D(min)) and quality indices (DNR [dose nonuniformity ratio], DHI [dose homogeneity index], CI [coverage index], COIN [conformal index]) were calculated. Maximum dose in reference points of rectum (D(r)) and urethra (D(u)), dose to volume of 2 cm(3) of the rectum (D(2ccm)), and 0.1 cm(3) and 1% of the urethra (D(0.1ccm) and D1) were determined. Nonparametric correlation analysis was performed between these parameters. The median number of needles was 16, the mean prostate volume (V(p)) was 27.1 cm(3). The mean V90, V100, V150, and V200 were 99%, 97%, 39%, and 13%, respectively. The mean D90 was 109%, and the D(min) was 87%. The mean doses in rectum and urethra reference points were 75% and 119%, respectively. The mean volumetric doses were D(2ccm) = 49% for the rectum, D(0.1ccm) = 126%, and D1 = 140% for the urethra. The mean DNR was 0.37, while the DHI was 0.60. The mean COIN was 0.66. The Spearman rank order correlation coefficients for volume doses to rectum and urethra were R(D(r),D(2ccm)) = 0.69, R(D(u),D0.(1ccm)) = 0.64, R(D(u),D1) = 0.23. US-based treatment plans for HDR prostate implants based on the real positions of catheters provided acceptable dose distributions. In the majority of the cases, the doses to urethra and rectum were kept below the defined tolerance levels. For rectum, the dose in reference points correlated well with dose-volume parameters. For urethra dose characterization, the use of D1 volumetric parameter is recommended.

  10. A cross-sectional vaccination coverage study in preschool children attending nurseries-kindergartens: Implications on economic crisis effect

    PubMed Central

    Menegas, Damianos; Katsioulis, Antonis; Theodoridou, Maria; Kremastinou, Jenny; Hadjichristodoulou, Christos

    2017-01-01

    ABSTRACT Vaccination coverage studies are important in determining a population's vaccination status and strategically adjusting national immunization programs. This study assessed full and timely vaccination coverage of preschool children aged 2–3 y attending nurseries-kindergartens (N-K) nationwide at the socioeconomic crisis onset. Geographically stratified cluster sampling was implemented considering prefectures as strata and N-K as clusters. The N-K were selected by simple random sampling from the sampling frame while their number was proportional to the stratum size. In total, 185 N-K (response rate 93.9%) and 2539 children (response rate 81.5%) participated. Coverage with traditional vaccines for diphtheria-tetanus-pertussis, polio and measles-mumps-rubella was very high (>95%), followed by Haemophilus influenzae type b and varicella vaccines. Despite very high final coverage, delayed vaccination was observed for hepatitis B (48.3% completed by 12 months). Significant delay was observed for the booster dose of pneumococcal conjugate vaccines (PCV) and meningococcal C conjugate vaccines (MCC). Of the total population studied, 82.3% received 3 PCV doses by 12 months, while 62.3% received the fourth dose by 24 months and 76.2% by 30 months. However, 89.6% received at least one MCC dose over 12 months. Timely vaccinated for hepatitis A with 2 doses by 24 months were 6.1%. Coverage was significantly low for Rotavirus (<20%) and influenza (23.1% one dose). High vaccination coverage is maintained for most vaccines at the beginning of the crisis in Greece. Coverage and timeliness show an increasing trend compared to previous studies. Sustained efforts are needed to support the preventive medicine system as socioeconomic instability continues. PMID:27669156

  11. [Vaccination coverage against hepatitis B in first-grade children, Paris, 2002-2008].

    PubMed

    Personne, V; Benainous, O; Lévy-Bruhl, D; Gilberg, S

    2015-08-01

    The French controversy over the possible risks of vaccination against hepatitis B seems to have resulted in a slowdown or delay in vaccination of target populations since the mid-1990s. This article reports the results of the analysis of vaccination coverage against hepatitis B of first-grade children in Paris between 2002 and 2008. Retrospective and descriptive study of vaccination status against hepatitis B for children born between 1997 and 2002 and attending first grade in a Paris school between 2002 and 2008, using anonymous data from the prevention service of the city of Paris. The analysis included 108,114 children whose Health Book (carnet de santé) included sociodemographic data and the presence of at least one diphtheria-tetanus-polio vaccination. Among these targeted children, 66,597 (61.6%) had started a vaccination against hepatitis B, 61,190 (56.6%) were considered "vaccinated" (at least three doses), and 47,489 (43.9%) "adequately vaccinated" (at least three doses respecting the prescribed intervals between injections). The sociodemographic factors associated with hepatitis B coverage were as follows: Paris arrondissement where the child attended school, year, and country of birth. Nearly 40% of the children in this cohort had not been vaccinated against hepatitis B before beginning first grade. They have now become adolescents aged 12-17 years. Current data indicate that only one-third of them have benefited from the catch-up campaign. This finding reinforces the need for vigilance on the vaccination status of adolescents against hepatitis B. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  12. Low dose megavoltage cone beam computed tomography with an unflattened 4 MV beam from a carbon target

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Faddegon, Bruce A.; Wu, Vincent; Pouliot, Jean

    2008-12-15

    Megavoltage cone beam computed tomography (MVCBCT) is routinely used for visualizing anatomical structures and implanted fiducials for patient positioning in radiotherapy. MVCBCT using a 6 MV treatment beam with high atomic number (Z) target and flattening filter in the beamline, as done conventionally, has lower image quality than can be achieved with a MV beam due to heavy filtration of the low-energy bremsstrahlung. The unflattened beam of a low Z target has an abundance of diagnostic energy photons, detected with modern flat panel detectors with much higher efficiency given the same dose to the patient. This principle guided the developmentmore » of a new megavoltage imaging beamline (IBL) for a commercial radiotherapy linear accelerator. A carbon target was placed in one of the electron primary scattering foil slots on the target-foil slide. A PROM on a function controller board was programed to put the carbon target in place for MVCBCT. A low accelerating potential of 4.2 MV was used for the IBL to restrict leakage of primary electrons through the target such that dose from x rays dominated the signal in the monitor chamber and the patient surface dose. Results from phantom and cadaver images demonstrated that the IBL had much improved image quality over the treatment beam. For similar imaging dose, the IBL improved the contrast-to-noise ratio by as much as a factor of 3 in soft tissue over that of the treatment beam. The IBL increased the spatial resolution by about a factor of 2, allowing the visualization of finer anatomical details. Images of the cadaver contained useful information with doses as low as 1 cGy. The IBL may be installed on certain models of linear accelerators without mechanical modification and results in significant improvement in the image quality with the same dose, or images of the same quality with less than one-third of the dose.« less

  13. Dose painting to treat single-lobe prostate cancer with hypofractionated high-dose radiation using targeted external beam radiation: Is it feasible?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amini, Arya; Westerly, David C.; Waxweiler, Timothy V.

    Targeted focal therapy strategies for treating single-lobe prostate cancer are under investigation. In this planning study, we investigate the feasibility of treating a portion of the prostate to full-dose external beam radiation with reduced dose to the opposite lobe, compared with full-dose radiation delivered to the entire gland using hypofractionated radiation. For 10 consecutive patients with low- to intermediate-risk prostate cancer, 2 hypofractionated, single-arc volumetric-modulated arc therapy (VMAT) plans were designed. The first plan (standard hypofractionation regimen [STD]) included the entire prostate gland, treated to 70 Gy delivered in 28 fractions. The second dose painting plan (DP) encompassed the involvedmore » lobe treated to 70 Gy delivered in 28 fractions, whereas the opposing, uninvolved lobe received 50.4 Gy in 28 fractions. Mean dose to the opposing neurovascular bundle (NVB) was considerably lower for DP vs STD, with a mean dose of 53.9 vs 72.3 Gy (p < 0.001). Mean penile bulb dose was 18.6 Gy for DP vs 19.2 Gy for STD (p = 0.880). Mean rectal dose was 21.0 Gy for DP vs 22.8 Gy for STD (p = 0.356). Rectum V{sub 70} (the volume receiving ≥70 Gy) was 2.01% for DP vs 2.74% for STD (p = 0.328). Bladder V{sub 70} was 1.69% for DP vs 2.78% for STD (p = 0.232). Planning target volume (PTV) maximum dose points were 76.5 and 76.3 Gy for DP and STD, respectively (p = 0.760). This study demonstrates the feasibility of using VMAT for partial-lobe prostate radiation in patients with prostate cancer involving 1 lobe. Partial-lobe prostate plans appeared to spare adjacent critical structures including the opposite NVB.« less

  14. Radionuclide production and dose rate estimation during the commissioning of the W-Ta spallation target

    NASA Astrophysics Data System (ADS)

    Yu, Q. Z.; Liang, T. J.

    2018-06-01

    China Spallation Neutron Source (CSNS) is intended to begin operation in 2018. CSNS is an accelerator-base multidisciplinary user facility. The pulsed neutrons are produced by a 1.6GeV short-pulsed proton beam impinging on a W-Ta spallation target, at a beam power of100 kW and a repetition rate of 25 Hz. 20 neutron beam lines are extracted for the neutron scattering and neutron irradiation research. During the commissioning and maintenance scenarios, the gamma rays induced from the W-Ta target can cause the dose threat to the personal and the environment. In this paper, the gamma dose rate distributions for the W-Ta spallation are calculated, based on the engineering model of the target-moderator-reflector system. The shipping cask is analyzed to satisfy the dose rate limit that less than 2 mSv/h at the surface of the shipping cask. All calculations are performed by the Monte carlo code MCNPX2.5 and the activation code CINDER’90.

  15. Targeting MRS-Defined Dominant Intraprostatic Lesions with Inverse-Planned High Dose Rate Brachytherapy

    DTIC Science & Technology

    2008-06-01

    brachytherapy treatment planning has been demonstrated. Using the inverse planning program IPSA , dose escalation of target regions with a higher tumor...algorithm (called IPSA ) was used to generate dose distributions for five different levels of DIL- boost, at least 110%, 120%, 130%, 140% and 150...and LDR, VI Last Generation Radiotherapy Course, São Paulo, Brazil, Oct. 19, 2006. Principles and Clinical Applications of IPSA ; Nucletron

  16. Salivary gland sparing and improved target irradiation by conformal and intensity modulated irradiation of head and neck cancer.

    PubMed

    Eisbruch, Avraham; Ship, Jonathan A; Dawson, Laura A; Kim, Hyungjin M; Bradford, Carol R; Terrell, Jeffrey E; Chepeha, Douglas B; Teknos, Theodore N; Hogikyan, Norman D; Anzai, Yoshimi; Marsh, Lon H; Ten Haken, Randall K; Wolf, Gregory T

    2003-07-01

    The goals of this study were to facilitate sparing of the major salivary glands while adequately treating tumor targets in patients requiring comprehensive bilateral neck irradiation (RT), and to assess the potential for improved xerostomia. Since 1994 techniques of target irradiation and locoregional tumor control with conformal and intensity modulated radiation therapy (IMRT) have been developed. In patients treated with these modalities, the salivary flow rates before and periodically after RT have been measured selectively from each major salivary gland and the residual flows correlated with glands' dose volume histograms (DVHs). In addition, subjective xerostomia questionnaires have been developed and validated. The pattern of locoregional recurrence has been examined from computed tomography (CT) scans at the time of recurrence, transferring the recurrence volumes to the planning CT scans, and regenerating the dose distributions at the recurrence sites. Treatment plans for target coverage and dose homogeneity using static, multisegmental IMRT were found to be significantly better than standard RT plans. In addition, significant parotid gland sparing was achieved in the conformal plans. The relationships among dose, irradiated volume, and the residual saliva flow rates from the parotid glands were characterized by dose and volume thresholds. A mean radiation dose of 26 Gy was found to be the threshold for preserved stimulated saliva flow. Xerostomia questionnaire scores suggested that xerostomia was significantly reduced in patients irradiated with bilateral neck, parotid-sparing RT, compared to patients with similar tumors treated with standard RT. Examination of locoregional tumor recurrence patterns revealed that the large majority of recurrences occurred inside targets, in areas that had been judged to be at high risk and that had received RT doses according to the perceived risk. Tangible gains in salivary gland sparing and target coverage are being

  17. Vaccination coverage among foreign-born and U.S.-born adolescents in the United States: Successes and gaps - National Immunization Survey-Teen, 2012-2014.

    PubMed

    Healy, Jessica; Rodriguez-Lainz, Alfonso; Elam-Evans, Laurie D; Hill, Holly A; Reagan-Steiner, Sarah; Yankey, David

    2018-03-20

    An overall increase has been reported in vaccination rates among adolescents during the past decade. Studies of vaccination coverage have shown disparities when comparing foreign-born and U.S.-born populations among children and adults; however, limited information is available concerning potential disparities in adolescents. The National Immunization Survey-Teen is a random-digit-dialed telephone survey of caregivers of adolescents aged 13-17 years, followed by a mail survey to vaccination providers that is used to estimate vaccination coverage among the U.S. population of adolescents. Using the National Immunization Survey-Teen data, we assessed vaccination coverage during 2012-2014 among adolescents for routinely recommended vaccines for this age group (≥1 dose tetanus and diphtheria toxoids and acellular pertussis [Tdap] vaccine, ≥1 dose quadrivalent meningococcal conjugate [MenACWY] vaccine, ≥3 doses human papillomavirus [HPV] vaccine) and for routine childhood vaccination catch-up doses (≥2 doses measles, mumps, and rubella [MMR] vaccine, ≥2 doses varicella vaccine, and ≥3 doses hepatitis B [HepB] vaccine). Vaccination coverage prevalence and vaccination prevalence ratios were estimated. Of the 58,090 respondents included, 3.3% were foreign-born adolescents. Significant differences were observed between foreign-born and U.S.-born adolescents for insurance status, income-to-poverty ratio, education, interview language, and household size. Foreign-born adolescents had significantly lower unadjusted vaccination coverage for HepB (89% vs. 93%), and higher coverage for the recommended ≥3 doses of HPV vaccine among males, compared with U.S.-born adolescents (22% vs. 14%). Adjustment for demographic and socioeconomic factors accounted for the disparity in HPV but not HepB vaccination coverage. We report comparable unadjusted vaccination coverage among foreign-born and U.S.-born adolescents for Tdap, MenACWY, MMR, ≥2 varicella. Although coverage was

  18. WE-DE-201-01: BEST IN PHYSICS (THERAPY): A Fast Multi-Target Inverse Treatment Planning Strategy Optimizing Dosimetric Measures for High-Dose-Rate (HDR) Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guthier, C; University Medical Center Mannheim, Mannheim; Harvard Medical School, Boston, MA

    Purpose: Inverse treatment planning (ITP) for interstitial HDR brachytherapy of gynecologic cancers seeks to maximize coverage of the clinical target volumes (tumor and vagina) while respecting dose-volume-histogram related dosimetric measures (DMs) for organs at risk (OARs). Commercially available ITP tools do not support DM-based planning because it is computationally too expensive to solve. In this study we present a novel approach that allows fast ITP for gynecologic cancers based on DMs for the first time. Methods: This novel strategy is an optimization model based on a smooth DM-based objective function. The smooth approximation is achieved by utilizing a logistic functionmore » for the evaluation of DMs. The resulting nonconvex and constrained optimization problem is then optimized with a BFGS algorithm. The model was evaluated using the implant geometry extracted from 20 patient treatment plans under an IRB-approved retrospective study. For each plan, the final DMs were evaluated and compared to the original clinical plans. The CTVs were the contoured tumor volume and the contoured surface of the vagina. Statistical significance was evaluated with a one-sided paired Wilcoxon signed-rank test. Results: As did the clinical plans, all generated plans fulfilled the defined DMs for OARs. The proposed strategy showed a statistically significant improvement (p<0.001) in coverage of the tumor and vagina, with absolute improvements of related DMs of (6.9 +/− 7.9)% and (28.2 +/− 12.0)%, respectively. This was achieved with a statistically significant (p<0.01) decrease of the high-dose-related DM for the tumor. The runtime of the optimization was (2.3 +/− 2.0) seconds. Conclusion: We demonstrated using clinical data that our novel approach allows rapid DM-based optimization with improved coverage of CTVs with fewer hot spots. Being up to three orders of magnitude faster than the current clinical practice, the method dramatically shortens planning time.« less

  19. [Comparison of planning quality and delivery efficiency between volumetric modulated arc therapy and dynamic intensity modulated radiation therapy for nasopharyngeal carcinoma with more than 4 prescribed dose levels].

    PubMed

    Jia, Pengfei; Xu, Jun; Zhou, Xiaoxi; Chen, Jian; Tang, Lemin

    2017-12-01

    The aim of this study is to compare the planning quality and delivery efficiency between dynamic intensity modulated radiation therapy (d-IMRT) and dual arc volumetric modulated arc therapy (VMAT) systematically for nasopharyngeal carcinoma (NPC) patients with multi-prescribed dose levels, and to analyze the correlations between target volumes and plan qualities. A total of 20 patients of NPC with 4-5 prescribed dose levels to achieve simultaneous integrated boost (SIB) treated by sliding window d-IMRT in our department from 2014 to 2015 were re-planned with dual arc VMAT. All optimization objectives for each VMAT plan were as the same as the corresponding d-IMRT plan. The dose parameters for targets and organ at risk (OAR), the delivery time and monitor units (MU) in two sets of plans were compared respectively. The treatment accuracy was tested by three dimensional dose validation system. Finally, the correlations between the difference of planning quality and the volume of targets were discussed. The conform indexes (CIs) of planning target volumes (PTVs) in VMAT plans were obviously high than those in d-IMRT plans ( P < 0.05), but no significant correlations between the difference of CIs and the volume of targets were discovered ( P > 0.05). The target coverage and heterogeneity indexes (HIs) of PTV 1 and PGTV nd and PTV 3 in two sets of plans were consistent. The doses of PTV 2 decreased and HIs were worse in VMAT plans. VMAT could provide better spinal cord and brainstem sparing, but increase mean dose of parotids. The average number of MUs and delivery time for d-IMRT were 3.32 and 2.19 times of that for VMAT. The γ-index (3 mm, 3%) analysis for each plans was more than 97% in COMPASS ® measurement for quality assurance (QA). The results show that target dose coverages in d-IMRT and VMAT plans are similar for NPC with multi-prescribed dose levels. VMAT could improve the the CIs of targets, but reduce the dose to the target volume in neck except for PGTV nd

  20. Treatment planning with intensity modulated particle therapy for multiple targets in stage IV non-small cell lung cancer

    NASA Astrophysics Data System (ADS)

    Anderle, Kristjan; Stroom, Joep; Vieira, Sandra; Pimentel, Nuno; Greco, Carlo; Durante, Marco; Graeff, Christian

    2018-01-01

    Intensity modulated particle therapy (IMPT) can produce highly conformal plans, but is limited in advanced lung cancer patients with multiple lesions due to motion and planning complexity. A 4D IMPT optimization including all motion states was expanded to include multiple targets, where each target (isocenter) is designated to specific field(s). Furthermore, to achieve stereotactic treatment planning objectives, target and OAR weights plus objective doses were automatically iteratively adapted. Finally, 4D doses were calculated for different motion scenarios. The results from our algorithm were compared to clinical stereotactic body radiation treatment (SBRT) plans. The study included eight patients with 24 lesions in total. Intended dose regimen for SBRT was 24 Gy in one fraction, but lower fractionated doses had to be delivered in three cases due to OAR constraints or failed plan quality assurance. The resulting IMPT treatment plans had no significant difference in target coverage compared to SBRT treatment plans. Average maximum point dose and dose to specific volume in OARs were on average 65% and 22% smaller with IMPT. IMPT could also deliver 24 Gy in one fraction in a patient where SBRT was limited due to the OAR vicinity. The developed algorithm shows the potential of IMPT in treatment of multiple moving targets in a complex geometry.

  1. The performance of the progressive resolution optimizer (PRO) for RapidArc planning in targets with low-density media.

    PubMed

    Kan, Monica W K; Leung, Lucullus H T; Yu, Peter K N

    2013-11-04

    A new version of progressive resolution optimizer (PRO) with an option of air cavity correction has been implemented for RapidArc volumetric-modulated arc therapy (RA). The purpose of this study was to compare the performance of this new PRO with the use of air cavity correction option (PRO10_air) against the one without the use of the air cavity correction option (PRO10_no-air) for RapidArc planning in targets with low-density media of different sizes and complexities. The performance of PRO10_no-air and PRO10_air was initially compared using single-arc plans created for four different simple heterogeneous phantoms with virtual targets and organs at risk. Multiple-arc planning of 12 real patients having nasopharyngeal carcinomas (NPC) and ten patients having non-small cell lung cancer (NSCLC) were then performed using the above two options for further comparison. Dose calculations were performed using both the Acuros XB (AXB) algorithm with the dose to medium option and the analytical anisotropic algorithm (AAA). The effect of using intermediate dose option after the first optimization cycle in PRO10_air and PRO10_no-air was also investigated and compared. Plans were evaluated and compared using target dose coverage, critical organ sparing, conformity index, and dose homogeneity index. For NSCLC cases or cases for which large volumes of low-density media were present in or adjacent to the target volume, the use of the air cavity correction option in PRO10 was shown to be beneficial. For NPC cases or cases for which small volumes of both low- and high-density media existed in the target volume, the use of air cavity correction in PRO10 did not improve the plan quality. Based on the AXB dose calculation results, the use of PRO10_air could produce up to 18% less coverage to the bony structures of the planning target volumes for NPC cases. When the intermediate dose option in PRO10 was used, there was negligible difference observed in plan quality between

  2. The performance of the progressive resolution optimizer (PRO) for RapidArc planning in targets with low‐density media

    PubMed Central

    Leung, Lucullus H.T.; Yu, Peter K.N.

    2013-01-01

    A new version of progressive resolution optimizer (PRO) with an option of air cavity correction has been implemented for RapidArc volumetric‐modulated arc therapy (RA). The purpose of this study was to compare the performance of this new PRO with the use of air cavity correction option (PRO10_air) against the one without the use of the air cavity correction option (PRO10_no‐air) for RapidArc planning in targets with low‐density media of different sizes and complexities. The performance of PRO10_no‐air and PRO10_air was initially compared using single‐arc plans created for four different simple heterogeneous phantoms with virtual targets and organs at risk. Multiple‐arc planning of 12 real patients having nasopharyngeal carcinomas (NPC) and ten patients having non‐small cell lung cancer (NSCLC) were then performed using the above two options for further comparison. Dose calculations were performed using both the Acuros XB (AXB) algorithm with the dose to medium option and the analytical anisotropic algorithm (AAA). The effect of using intermediate dose option after the first optimization cycle in PRO10_air and PRO10_no‐air was also investigated and compared. Plans were evaluated and compared using target dose coverage, critical organ sparing, conformity index, and dose homogeneity index. For NSCLC cases or cases for which large volumes of low‐density media were present in or adjacent to the target volume, the use of the air cavity correction option in PROIO was shown to be beneficial. For NPC cases or cases for which small volumes of both low‐ and high‐density media existed in the target volume, the use of air cavity correction in PRO10 did not improve the plan quality. Based on the AXB dose calculation results, the use of PRO10_air could produce up to 18% less coverage to the bony structures of the planning target volumes for NPC cases. When the intermediate dose option in PRO10 was used, there was negligible difference observed in plan

  3. Comparison of composite prostate radiotherapy plan doses with dependent and independent boost phases.

    PubMed

    Narayanasamy, Ganesh; Avila, Gabrielle; Mavroidis, Panayiotis; Papanikolaou, Niko; Gutierrez, Alonso; Baacke, Diana; Shi, Zheng; Stathakis, Sotirios

    2016-09-01

    Prostate cases commonly consist of dual phase planning with a primary plan followed by a boost. Traditionally, the boost phase is planned independently from the primary plan with the risk of generating hot or cold spots in the composite plan. Alternatively, boost phase can be planned taking into account the primary dose. The aim of this study was to compare the composite plans from independently and dependently planned boosts using dosimetric and radiobiological metrics. Ten consecutive prostate patients previously treated at our institution were used to conduct this study on the Raystation™ 4.0 treatment planning system. For each patient, two composite plans were developed: a primary plan with an independently planned boost and a primary plan with a dependently planned boost phase. The primary plan was prescribed to 54 Gy in 30 fractions to the primary planning target volume (PTV1) which includes prostate and seminal vesicles, while the boost phases were prescribed to 24 Gy in 12 fractions to the boost planning target volume (PTV2) that targets only the prostate. PTV coverage, max dose, median dose, target conformity, dose homogeneity, dose to OARs, and probabilities of benefit, injury, and complication-free tumor control (P+) were compared. Statistical significance was tested using either a 2-tailed Student's t-test or Wilcoxon signed-rank test. Dosimetrically, the composite plan with dependent boost phase exhibited smaller hotspots, lower maximum dose to the target without any significant change to normal tissue dose. Radiobiologically, for all but one patient, the percent difference in the P+ values between the two methods was not significant. A large percent difference in P+ value could be attributed to an inferior primary plan. The benefits of considering the dose in primary plan while planning the boost is not significant unless a poor primary plan was achieved.

  4. Does closure of children's medical home impact their immunization coverage?

    PubMed

    Kolasa, M S; Stevenson, J; Ossa, A; Lutz, J

    2014-12-01

    Little is known about the impact closing a health care facility has on immunization coverage of children utilizing that facility as a medical home. The authors assessed the impact of closing a Medicaid managed care facility in Philadelphia on immunization coverage of children, primarily low income children from racial/ethnic minority groups, utilizing that facility for routine immunizations. Observational longitudinal cohort case study. Eligible children were born 03/01/05-06/30/07, present in Philadelphia's immunization information system (IIS), and were active clients of the facility before it closed in September 2007. IIS-recorded immunization coverage at ages 5, 7, 13, 16 and 19 months through January 2009 was compared between clinic children age-eligible to receive specific vaccines before clinic closing (preclosure cohorts) and children not age-eligible to receive those vaccines prior to closing (postclosure cohorts). Of 630 eligible children, 99 (16%) had no additional IIS-recorded immunizations. Third dose DTaP vaccine coverage at age seven months among preclosure cohorts was 54.4% vs. 40.3% among postclosure cohorts [risk ratio 1.31 (1.15,1.49)]. Fourth dose DTaP coverage at 19 months was 65.9% vs. 57.7% [risk ratio 1.24 (1.08,1.42)]. MMR coverage at 16 months was 79.5% vs. 69.9% [risk ratio 1.47 (1.22, 1.76)]. Coverage for the 431331 vaccination series at 19 months was 63.8% vs. 53.8% [risk ratio 1.28 (1.12,1.88)]. Immunization coverage declined at key age milestones for active clients of a Medicaid managed care that closed as compared with preclosure cohorts of clients from the same facility. When a primary health care facility closes, efforts should be made to ensure that children who had received vaccinations at that facility quickly establish a new medical home. Published by Elsevier Ltd.

  5. Assessing vaccination coverage in infants, survey studies versus the Flemish immunisation register: achieving the best of both worlds.

    PubMed

    Braeckman, Tessa; Lernout, Tinne; Top, Geert; Paeps, Annick; Roelants, Mathieu; Hoppenbrouwers, Karel; Van Damme, Pierre; Theeten, Heidi

    2014-01-09

    Infant immunisation coverage in Flanders, Belgium, is monitored through repeated coverage surveys. With the increased use of Vaccinnet, the web-based ordering system for vaccines in Flanders set up in 2004 and linked to an immunisation register, this database could become an alternative to quickly estimate vaccination coverage. To evaluate its current accuracy, coverage estimates generated from Vaccinnet alone were compared with estimates from the most recent survey (2012) that combined interview data with data from Vaccinnet and medical files. Coverage rates from registrations in Vaccinnet were systematically lower than the corresponding estimates obtained through the survey (mean difference 7.7%). This difference increased by dose number for vaccines that require multiple doses. Differences in administration date between the two sources were observed for 3.8-8.2% of registered doses. Underparticipation in Vaccinnet thus significantly impacts on the register-based immunisation coverage estimates, amplified by underregistration of administered doses among vaccinators using Vaccinnet. Therefore, survey studies, despite being labour-intensive and expensive, currently provide more complete and reliable results than register-based estimates alone in Flanders. However, further improvement of Vaccinnet's completeness will likely allow more accurate estimates in the nearby future. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Factors associated with photoprotection by body clothing coverage, particularly in non-summer months, among a New Zealand community sample.

    PubMed

    Reeder, Anthony I; Gray, Andrew R; Liley, J Ben; Scragg, Robert K R; McKenzie, Richard L; Stewart, Alistair W

    2016-03-01

    Clothing coverage is important for reducing skin cancer risk, but may also influence vitamin D sufficiency, so associated plausible predictors require investigation. Volunteers (18 to 85 years), with approximately equal numbers by sex and four ethnicity groups, were recruited in cities from two latitude bands: Auckland (36.9°S) and Dunedin (45.9°S). Baseline questionnaire, anthropometric and spectrophotometer skin colour data were collected and weather data obtained. Percent body coverage was calculated from eight week diary records. Potential independent predictors (unadjusted p < 0.25) were included in adjusted models. Participants (n = 506: Auckland n = 334, Dunedin n = 172; mean age 48.4 years) were 62.7% female and had a median body clothing coverage of 81.6% (IQR 9.3%). Dunedin was cooler, less windy and had lower UVI levels than Auckland. From the fully adjusted model, increased coverage occurred in non-summer months (despite adjusting for weather), among Dunedin residents and Asians (compared to Europeans), during the middle of the day, with a dose response effect observed for greater age. Reduced coverage was associated with Pacific ethnicity and greater time spent outdoors. Additionally, higher temperatures were associated with reduced coverage, whereas increased cloud cover and wind speed were associated with increased coverage. Although the only potentially modifiable factors associated with clothing coverage were the time period and time spent outdoors, knowledge of these and other associated factors is useful for the framing and targeting of health promotion messages to potentially influence clothing coverage, facilitate erythema avoidance and maintain vitamin D sufficiency.

  7. SU-E-T-10: A Clinical Implementation and the Dosimetric Evidence in High Dose Rate Vaginal Multichannel Applicator Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Syh, J; Syh, J; Patel, B

    2015-06-15

    Purpose: The multichannel cylindrical applicator has a distinctive modification of the traditional single channel cylindrical applicator. The novel multichannel applicator has additional peripheral channels that provide more flexibility both in treatment planning process and outcomes. To protect by reducing doses to adjacent organ at risk (OAR) while maintaining target coverage with inverse plan optimization are the goals for such novel Brachytherapy device. Through a series of comparison and analysis of reults in more than forty patients who received HDR Brachytherapy using multichannel vaginal applicator, this procedure has been implemented in our institution. Methods: Multichannel planning was CT image based. Themore » CTV of 5mm vaginal cuff rind with prescribed length was well reconstructed as well as bladder and rectum. At least D95 of CTV coverage is 95% of prescribed dose. Multichannel inverse plan optimization algorithm not only shapes target dose cloud but set dose avoids to OAR’s exclusively. The doses of D2cc, D5cc and D5; volume of V2Gy in OAR’s were selected to compare with single channel results when sole central channel is only possibility. Results: Study demonstrates plan superiorly in OAR’s doe reduction in multi-channel plan. The D2cc of the rectum and bladder were showing a little lower for multichannel vs. single channel. The V2Gy of the rectum was 93.72% vs. 83.79% (p=0.007) for single channel vs. multichannel respectively. Absolute reduced mean dose of D5 by multichannel was 17 cGy (s.d.=6.4) and 44 cGy (s.d.=15.2) in bladder and rectum respectively. Conclusion: The optimization solution in multichannel was to maintain D95 CTV coverage while reducing the dose to OAR’s. Dosimetric advantage in sparing critical organs by using a multichannel applicator in HDR Brachytherapy treatment of the vaginal cuff is so promising and has been implemented clinically.« less

  8. Monitoring intervention coverage in the context of universal health coverage.

    PubMed

    Boerma, Ties; AbouZahr, Carla; Evans, David; Evans, Tim

    2014-09-01

    Monitoring universal health coverage (UHC) focuses on information on health intervention coverage and financial protection. This paper addresses monitoring intervention coverage, related to the full spectrum of UHC, including health promotion and disease prevention, treatment, rehabilitation, and palliation. A comprehensive core set of indicators most relevant to the country situation should be monitored on a regular basis as part of health progress and systems performance assessment for all countries. UHC monitoring should be embedded in a broad results framework for the country health system, but focus on indicators related to the coverage of interventions that most directly reflect the results of UHC investments and strategies in each country. A set of tracer coverage indicators can be selected, divided into two groups-promotion/prevention, and treatment/care-as illustrated in this paper. Disaggregation of the indicators by the main equity stratifiers is critical to monitor progress in all population groups. Targets need to be set in accordance with baselines, historical rate of progress, and measurement considerations. Critical measurement gaps also exist, especially for treatment indicators, covering issues such as mental health, injuries, chronic conditions, surgical interventions, rehabilitation, and palliation. Consequently, further research and proxy indicators need to be used in the interim. Ideally, indicators should include a quality of intervention dimension. For some interventions, use of a single indicator is feasible, such as management of hypertension; but in many areas additional indicators are needed to capture quality of service provision. The monitoring of UHC has significant implications for health information systems. Major data gaps will need to be filled. At a minimum, countries will need to administer regular household health surveys with biological and clinical data collection. Countries will also need to improve the production of

  9. Monitoring Intervention Coverage in the Context of Universal Health Coverage

    PubMed Central

    Boerma, Ties; AbouZahr, Carla; Evans, David; Evans, Tim

    2014-01-01

    Monitoring universal health coverage (UHC) focuses on information on health intervention coverage and financial protection. This paper addresses monitoring intervention coverage, related to the full spectrum of UHC, including health promotion and disease prevention, treatment, rehabilitation, and palliation. A comprehensive core set of indicators most relevant to the country situation should be monitored on a regular basis as part of health progress and systems performance assessment for all countries. UHC monitoring should be embedded in a broad results framework for the country health system, but focus on indicators related to the coverage of interventions that most directly reflect the results of UHC investments and strategies in each country. A set of tracer coverage indicators can be selected, divided into two groups—promotion/prevention, and treatment/care—as illustrated in this paper. Disaggregation of the indicators by the main equity stratifiers is critical to monitor progress in all population groups. Targets need to be set in accordance with baselines, historical rate of progress, and measurement considerations. Critical measurement gaps also exist, especially for treatment indicators, covering issues such as mental health, injuries, chronic conditions, surgical interventions, rehabilitation, and palliation. Consequently, further research and proxy indicators need to be used in the interim. Ideally, indicators should include a quality of intervention dimension. For some interventions, use of a single indicator is feasible, such as management of hypertension; but in many areas additional indicators are needed to capture quality of service provision. The monitoring of UHC has significant implications for health information systems. Major data gaps will need to be filled. At a minimum, countries will need to administer regular household health surveys with biological and clinical data collection. Countries will also need to improve the production of

  10. Cardiac Dose Reduction with Deep-Inspiratory Breath Hold Technique of Radiotherapy for Left-Sided Breast Cancer.

    PubMed

    Sripathi, Lalitha Kameshwari; Ahlawat, Parveen; Simson, David K; Khadanga, Chira Ranjan; Kamarsu, Lakshmipathi; Surana, Shital Kumar; Arasu, Kavi; Singh, Harpreet

    2017-01-01

    Different techniques of radiation therapy have been studied to reduce the cardiac dose in left breast cancer. In this prospective dosimetric study, the doses to heart as well as other organs at risk (OAR) were compared between free-breathing (FB) and deep inspiratory breath hold (DIBH) techniques in intensity modulated radiotherapy (IMRT) and opposed-tangent three-dimensional radiotherapy (3DCRT) plans. Fifteen patients with left-sided breast cancer underwent computed tomography simulation and images were obtained in both FB and DIBH. Radiotherapy plans were generated with 3DCRT and IMRT techniques in FB and DIBH images in each patient. Target coverage, conformity index, homogeneity index, and mean dose to heart (Heart D mean ), left lung, left anterior descending artery (LAD) and right breast were compared between the four plans using the Wilcoxon signed rank test. Target coverage was adequate with both 3DCRT and IMRT plans, but IMRT plans showed better conformity and homogeneity. A statistically significant dose reduction of all OARs was found with DIBH. 3DCRT DIBH decreased the Heart D mean by 53.5% (7.1 vs. 3.3 Gy) and mean dose to LAD by 28% compared to 3DCRT FB . IMRT further lowered mean LAD dose by 18%. Heart D mean was lower with 3DCRT DIBH over IMRT DIBH (3.3 vs. 10.2 Gy). Mean dose to the contralateral breast was also lower with 3DCRT over IMRT (0.32 vs. 3.35 Gy). Mean dose and the V 20 of ipsilateral lung were lower with 3DCRT DIBH over IMRT DIBH (13.78 vs. 18.9 Gy) and (25.16 vs. 32.95%), respectively. 3DCRT DIBH provided excellent dosimetric results in patients with left-sided breast cancer without the need for IMRT.

  11. Cardiac Dose Reduction with Deep-Inspiratory Breath Hold Technique of Radiotherapy for Left-Sided Breast Cancer

    PubMed Central

    Sripathi, Lalitha Kameshwari; Ahlawat, Parveen; Simson, David K; Khadanga, Chira Ranjan; Kamarsu, Lakshmipathi; Surana, Shital Kumar; Arasu, Kavi; Singh, Harpreet

    2017-01-01

    Introduction: Different techniques of radiation therapy have been studied to reduce the cardiac dose in left breast cancer. Aim: In this prospective dosimetric study, the doses to heart as well as other organs at risk (OAR) were compared between free-breathing (FB) and deep inspiratory breath hold (DIBH) techniques in intensity modulated radiotherapy (IMRT) and opposed-tangent three-dimensional radiotherapy (3DCRT) plans. Materials and Methods: Fifteen patients with left-sided breast cancer underwent computed tomography simulation and images were obtained in both FB and DIBH. Radiotherapy plans were generated with 3DCRT and IMRT techniques in FB and DIBH images in each patient. Target coverage, conformity index, homogeneity index, and mean dose to heart (Heart Dmean), left lung, left anterior descending artery (LAD) and right breast were compared between the four plans using the Wilcoxon signed rank test. Results: Target coverage was adequate with both 3DCRT and IMRT plans, but IMRT plans showed better conformity and homogeneity. A statistically significant dose reduction of all OARs was found with DIBH. 3DCRTDIBH decreased the Heart Dmean by 53.5% (7.1 vs. 3.3 Gy) and mean dose to LAD by 28% compared to 3DCRTFB. IMRT further lowered mean LAD dose by 18%. Heart Dmean was lower with 3DCRTDIBH over IMRTDIBH (3.3 vs. 10.2 Gy). Mean dose to the contralateral breast was also lower with 3DCRT over IMRT (0.32 vs. 3.35 Gy). Mean dose and the V20 of ipsilateral lung were lower with 3DCRTDIBH over IMRTDIBH (13.78 vs. 18.9 Gy) and (25.16 vs. 32.95%), respectively. Conclusions: 3DCRTDIBH provided excellent dosimetric results in patients with left-sided breast cancer without the need for IMRT. PMID:28974856

  12. High-Dose and Extended-Field Intensity Modulated Radiation Therapy for Early-Stage NK/T-Cell Lymphoma of Waldeyer's Ring: Dosimetric Analysis and Clinical Outcome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bi, Xi-Wen; Li, Ye-Xiong, E-mail: yexiong@yahoo.com; Fang, Hui

    2013-12-01

    Purpose: To assess the dosimetric benefit, treatment outcome, and toxicity of high-dose and extended-field intensity modulated radiation therapy (IMRT) in patients with early-stage NK/T-cell lymphoma of Waldeyer's ring (WR-NKTCL). Methods and Materials: Thirty patients with early-stage WR-NKTCL who received extended-field IMRT were retrospectively reviewed. The prescribed dose was 50 Gy to the primary involved regions and positive cervical lymph nodes (planning target volume requiring radical irradiation [PTV{sub 50}]) and 40 Gy to the negative cervical nodes (PTV{sub 40}). Dosimetric parameters for the target volume and critical normal structures were evaluated. Locoregional control (LRC), overall survival (OS), and progression-free survival (PFS)more » were calculated using the Kaplan-Meier method. Results: The median mean doses to the PTV{sub 50} and PTV{sub 40} were 53.2 Gy and 43.0 Gy, respectively. Only 1.4% of the PTV{sub 50} and 0.9% of the PTV{sub 40} received less than 95% of the prescribed dose, indicating excellent target coverage. The average mean doses to the left and right parotid glands were 27.7 and 28.4 Gy, respectively. The 2-year OS, PFS, and LRC rates were 71.2%, 57.4%, and 87.8%. Most acute toxicities were grade 1 to 2, except for grade ≥3 dysphagia and mucositis. The most common late toxicity was grade 1-2 xerostomia, and no patient developed any ≥grade 3 late toxicities. A correlation between the mean dose to the parotid glands and the degree of late xerostomia was observed. Conclusions: IMRT achieves excellent target coverage and dose conformity, as well as favorable survival and locoregional control rates with acceptable toxicities in patients with WR-NKTCL.« less

  13. High-dose and extended-field intensity modulated radiation therapy for early-stage NK/T-cell lymphoma of Waldeyer's ring: dosimetric analysis and clinical outcome.

    PubMed

    Bi, Xi-Wen; Li, Ye-Xiong; Fang, Hui; Jin, Jing; Wang, Wei-Hu; Wang, Shu-Lian; Liu, Yue-Ping; Song, Yong-Wen; Ren, Hua; Dai, Jian-Rong

    2013-12-01

    To assess the dosimetric benefit, treatment outcome, and toxicity of high-dose and extended-field intensity modulated radiation therapy (IMRT) in patients with early-stage NK/T-cell lymphoma of Waldeyer's ring (WR-NKTCL). Thirty patients with early-stage WR-NKTCL who received extended-field IMRT were retrospectively reviewed. The prescribed dose was 50 Gy to the primary involved regions and positive cervical lymph nodes (planning target volume requiring radical irradiation [PTV50]) and 40 Gy to the negative cervical nodes (PTV40). Dosimetric parameters for the target volume and critical normal structures were evaluated. Locoregional control (LRC), overall survival (OS), and progression-free survival (PFS) were calculated using the Kaplan-Meier method. The median mean doses to the PTV50 and PTV40 were 53.2 Gy and 43.0 Gy, respectively. Only 1.4% of the PTV50 and 0.9% of the PTV40 received less than 95% of the prescribed dose, indicating excellent target coverage. The average mean doses to the left and right parotid glands were 27.7 and 28.4 Gy, respectively. The 2-year OS, PFS, and LRC rates were 71.2%, 57.4%, and 87.8%. Most acute toxicities were grade 1 to 2, except for grade ≥3 dysphagia and mucositis. The most common late toxicity was grade 1-2 xerostomia, and no patient developed any ≥grade 3 late toxicities. A correlation between the mean dose to the parotid glands and the degree of late xerostomia was observed. IMRT achieves excellent target coverage and dose conformity, as well as favorable survival and locoregional control rates with acceptable toxicities in patients with WR-NKTCL. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Oral Cholera Vaccine Coverage, Barriers to Vaccination, and Adverse Events following Vaccination, Haiti, 2013.

    PubMed

    Tohme, Rania A; François, Jeannot; Wannemuehler, Kathleen; Iyengar, Preetha; Dismer, Amber; Adrien, Paul; Hyde, Terri B; Marston, Barbara J; Date, Kashmira; Mintz, Eric; Katz, Mark A

    2015-06-01

    In 2013, the first government-led oral cholera vaccination (OCV) campaign in Haiti was implemented in Petite Anse and Cerca Carvajal. To evaluate vaccination coverage, barriers to vaccination, and adverse events following vaccination, we conducted a cluster survey. We enrolled 1,121 persons from Petite Anse and 809 persons from Cerca Carvajal, categorized by 3 age groups (1-4, 5-14, >15 years). Two-dose OCV coverage was 62.5% in Petite Anse and 76.8% in Cerca Carvajal. Two-dose coverage was lowest among persons >15 years of age. In Cerca Carvajal, coverage was significantly lower for male than female respondents (69% vs. 85%; p<0.001). No major adverse events were reported. The main reason for nonvaccination was absence during the campaign. Vaccination coverage after this campaign was acceptable and comparable to that resulting from campaigns implemented by nongovernmental organizations. Future campaigns should be tailored to reach adults who are not available during daytime hours.

  15. Coverage of childhood vaccination among children aged 12-23 months, Tamil Nadu, 2015, India.

    PubMed

    Murhekar, Manoj V; Kamaraj, P; Kanagasabai, K; Elavarasu, G; Rajasekar, T Daniel; Boopathi, K; Mehendale, Sanjay

    2017-03-01

    District-Level Household Survey-4 (DLHS-4) indicated that during 2012-2013, only 56 per cent of children aged 12-23 months in Tamil Nadu were fully vaccinated, which were lesser than those reported in earlier national surveys. We, therefore, conducted cluster surveys to estimate coverage of childhood vaccination in the State, and also to identify the factors associated with low coverage. Cross-sectional surveys were conducted in 15 strata [municipal corporation non-slum (n=1), municipal corporation slum (n=1), hilly (n=1), rural (n=6) and urban (n=6)]. From each stratum, 30 clusters were selected using probability proportional to the population size linear systematic sampling; seven children aged 12-23 months were selected from each cluster and their mothers/care-takers were interviewed to collect information about vaccination status of the child. A child was considered fully vaccinated if he/she received bacillus Calmette-Guérin (BCG), three doses of pentavalent, three doses of oral polio vaccine and one dose of measles vaccine, and appropriately vaccinated if all vaccine doses were given at right age and with right interval. Further, coverage of fully vaccinated children (FVC) as per vaccination cards or mothers' recall, validated coverage of FVC (V-FVC) among those having cards, and coverage of appropriately vaccinated children (AVC) were estimated using survey data analysis module with appropriate sampling weights. A total of 3150 children were surveyed, of them 2528 (80.3%) had vaccination card. The weighted coverage of FVC, V-FVC and AVC in the State was 79.9 per cent [95% confidence interval (CI): 78.2-81.5], 78.8 per cent (95% CI: 76.9-80.5) and 69.7 per cent (95% CI: 67.7-71.7), respectively. The coverage of individual vaccine ranged between 84 per cent (measles) and 99.8 per cent (BCG). About 12 per cent V-FVC were not vaccinated as per the vaccination schedule. The coverage of FVC in Tamil Nadu was high, with about 80 per cent children completing

  16. Human papillomavirus vaccination coverage among females and males, National Health and Nutrition Examination Survey, United States, 2007-2016.

    PubMed

    Lewis, Rayleen M; Markowitz, Lauri E

    2018-05-03

    Human papillomavirus (HPV) vaccination has been routinely recommended at age 11-12 years in the United States for females since 2006 and males since 2011. Coverage can be estimated using self/parent-reported HPV vaccination collected in the National Health and Nutrition Examination Survey (NHANES) for a wider age range than other national surveys. We assessed vaccination coverage in 2015-2016, temporal trends by age, and the validity of self/parent-reported vaccination status. Participants aged 9-59 years completed an interview collecting demographic and vaccination information. Weighted coverage was estimated for two-year NHANES cycles by age group for 2007-2008 to 2015-2016 for females (N = 14318) and 2011-2012 to 2015-2016 for males (N = 7847). Temporal trends in coverage were assessed from 2007-2008 to 2011-2012 for females and from 2011-2012 to 2015-2016 for both sexes. Sensitivity and specificity of self/parent-reported vaccination were assessed using provider-verified vaccination records from a pilot study in 14-29 year-olds. In 2015-2016, ≥1 dose coverage among females was highest in 14-19 (54.7%) and 20-24 (56.0%) year-olds and lower in successively older age groups. Among males, ≥1 dose coverage was highest in 14-19 year-olds (39.5%) and lower at older ages. Coverage was similar in 9-13 year-old females and males. Between 2007-2008 and 2011-2012, there were increases among females younger than 30 years. Between 2011-2012 and 2015-2016, there were increases among female age groups including 20-39 year-olds; male coverage increased among ages 9-13, 14-19, and 20-24 years. Self/parent-reported receipt of ≥1 dose had a sensitivity and specificity of 87.0% and 83.3%. Performance was lower for 3 doses. While overall HPV vaccination coverage remains low, it is higher in females than males, except in 9-13 year-olds. There have been increases in coverage among many age groups, but coverage has stalled in younger females. Adequate

  17. Water-filled balloon in the postoperative resection cavity improves dose distribution to target volumes in radiotherapy of maxillary sinus carcinoma.

    PubMed

    Zhang, Qun; Lin, Shi-Rong; He, Fang; Kang, De-Hua; Chen, Guo-Zhang; Luo, Wei

    2011-11-01

    Postoperative radiotherapy is a major treatment for patients with maxillary sinus carcinoma. However, the irregular resection cavity poses a technical difficulty for this treatment, causing uneven dose distribution to target volumes. In this study, we evaluated the dose distribution to target volumes and normal tissues in postoperative intensity-modulated radiotherapy (IMRT) after placing a water-filled balloon into the resection cavity. Three postoperative patients with advanced maxillary sinus carcinoma were selected in this trial. Water-filled balloons and supporting dental stents were fabricated according to the size of the maxillary resection cavity. Simulation CT scans were performed with or without water-filled balloons, IMRT treatment plans were established, and dose distribution to target volumes and organs at risk were evaluated. Compared to those in the treatment plan without balloons, the dose (D98) delivered to 98% of the gross tumor volume (GTV) increased by 2.1 Gy (P = 0.009), homogeneity index (HI) improved by 2.3% (P = 0.001), and target volume conformity index (TCI) of 68 Gy increased by 18.5% (P = 0.011) in the plan with balloons. Dosimetry endpoints of normal tissues around target regions in both plans were not significantly different (P > 0.05) except for the optic chiasm. In the plan without balloons, 68 Gy high-dose regions did not entirely cover target volumes in the ethmoid sinus, posteromedial wall of the maxillary sinus, or surgical margin of the hard palate. In contrast, 68 Gy high-dose regions entirely covered the GTV in the plan with balloons. These results suggest that placing a water-filled balloon in the resection cavity for postoperative IMRT of maxillary sinus carcinoma can reduce low-dose regions and markedly and simultaneously increase dose homogeneity and conformity of target volumes.

  18. Praziquantel coverage in schools and communities targeted for the elimination of urogenital schistosomiasis in Zanzibar: a cross-sectional survey.

    PubMed

    Knopp, Stefanie; Person, Bobbie; Ame, Shaali M; Ali, Said M; Muhsin, Juma; Juma, Saleh; Khamis, Iddi S; Rabone, Muriel; Blair, Lynsey; Fenwick, Alan; Mohammed, Khalfan A; Rollinson, David

    2016-01-04

    Biannual mass drug administration (MDA) with praziquantel and additional interventions to eliminate urogenital schistosomiasis has been implemented on the Zanzibar islands, United Republic of Tanzania, since 2012. We aimed to assess the coverage of school-based treatment (SBT) and community-wide treatment (CWT), to validate the coverage reported by the Zanzibar Ministry of Health (MoH) and to identify reasons for non-compliance. We conducted a post-MDA cross-sectional survey in 93 schools and 92 communities on Pemba and Unguja islands in early 2014, 3-5 months after the last MDA round. Pupils and adults were asked whether they had received and taken the praziquantel treatment provided in the last SBT or CWT, respectively, and the observed and reported coverage were compared. Reasons for non-compliance were recorded in a pretested questionnaire and assessed in qualitative interviews. Urine samples of participants were examined for Schistosoma haematobium eggs with a single urine filtration. Around 8000 pupils and 4000 adults were included in the analysis. Our survey revealed a SBT coverage of 85.2% in Pemba and of 86.9% in Unguja, which was in line with MoH reports from Pemba (84.3%) and higher than reports from Unguja (63.9%). However, 15 among the 48 schools surveyed in Unguja had not received SBT. Among the interviewed adults, 53.6% in Pemba and 64.9% in Unguja had received praziquantel during CWT, which was less than the 59.0% and 67.7%, respectively, indicated by MoH reports. Moreover, only 43.8% and 54.0% of adults in Pemba and Unguja, respectively, had taken all the tablets as recommended. The main reasons for not receiving or taking praziquantel were absence during CWT, no drug distributor coming, being busy, fear of adverse events, pregnancy, breastfeeding or feeling healthy. To increase coverage and compliance in Zanzibar, SBT should target all schools and mobilization, sensitization and implementation of the CWT need to be improved. To reach elimination

  19. SU-E-T-605: RapidArc Combined with DIBH Technique for Thoracic Esophageal Carcinoma: The Potential Value of Target Immobilization and Reduced Lung Density in Dose Escalation.

    PubMed

    Yin, Y; Liu, T; Zhai, D

    2012-06-01

    To compare the dosimetric benefits of Rapidarc (RA) combined with deep inspiration breath-hold (DIBH) with those of other standard techniques, including free breathing (FB) during fixed-field intensity modulated radiation therapy (IMRT) and dual arc RA, in the treatment of patients with thoracic esophageal carcinoma (EC). Ten patients with EC underwent computed tomography (CT) scans under 2 respiration conditions: free-breathing (FB) and DIBH. These scans were used to generate 3-dimensional conformal treatment plans. For breath-hold scans, the patients were brought to reproducible respiration levels using active breathing control (ABC) maneuvers. Planning target volumes (PTVs) for FB plans included a 0.5 cm margin for setup plus a 1 cm margin equal to the extent of tumor motion for respiration. PTVs for DIBH plans included a 0.5 cm margin for setup error and a 0.5 cm margin for residual uncertainty in tumor position. Using a dose level of 60 Gy to the PTV, three treatment plans were generated: IMRT-FB, RA-FB and RA-ABC, and the target and normal tissue volumes were compared, as were the dosimetry parameters. On average, the DIBH technique resulted in increased lung volumes compared with FB techniques. There was no significant differences in gross tumor volume between the two breathing states (p > 0.05); but PTV and heart volume were larger for FB than for DIBH (p < 0.05). The overall CI and HI for the RA-ABC plan was slightly inferior to those of the IMRT- FB and RA-FB plans (p < 0.05 each). With DIBH, the heart was partly out of the beam portals and the average mean heart dose was reduced. Compared with conventional FB, RA combined with DIBH significantly reduced cardiac and pulmonary doses without compromising the target coverage and may reduce treatment toxicity, enabling dose escalation in future prospective studies of patients with EC. © 2012 American Association of Physicists in Medicine.

  20. High and equitable mass vitamin A supplementation coverage in Sierra Leone: a post-event coverage survey.

    PubMed

    Hodges, Mary H; Sesay, Fatmata F; Kamara, Habib I; Turay, Mohamed; Koroma, Aminata S; Blankenship, Jessica L; Katcher, Heather I

    2013-08-01

    In Sierra Leone, children ages 6-59 months receive twice-yearly vitamin A supplementation (VAS) through Maternal and Child Health Week (MCHW) events. VAS coverage in 2011 was calculated using government tally sheets of vitamin A capsule distribution and outdated population projections from the 2004 census. We conducted a national post-event coverage (PEC) survey to validate coverage and inform strategies to reach universal coverage of VAS in Sierra Leone. Immediately following the November 2011 MCHW event, we conducted a national PEC survey by interviewing caregivers with children ages 6-59 months using a randomized 30X30 cluster design (N = 900). We also interviewed one health worker and one community health worker in each cluster to determine their knowledge about VAS (N = 60). VAS coverage was 91.8% among children ages 6-59 months, which was lower than the 105.1% reported through tally sheets. Coverage was high and equitable among all districts and between age groups (98.5% for infants ages 6-11 months and 90.5% for children ages 12-59 months). Major reasons for not receiving VAS were that the child was out of the area (42.4%), the household was not visited by community health workers (28.0%), and the caretaker was not aware of the event (11.9%). Twice-yearly delivery of VAS through MCHW events achieved consistently high and equitable coverage in Sierra Leone. Universal coverage may be achieved through continued focus on communication and targeted outreach to hard-to-reach areas during the MCHWs.

  1. Halobacterium salinarum NRC-1 PeptideAtlas: toward strategies for targeted proteomics and improved proteome coverage.

    PubMed

    Van, Phu T; Schmid, Amy K; King, Nichole L; Kaur, Amardeep; Pan, Min; Whitehead, Kenia; Koide, Tie; Facciotti, Marc T; Goo, Young Ah; Deutsch, Eric W; Reiss, David J; Mallick, Parag; Baliga, Nitin S

    2008-09-01

    The relatively small numbers of proteins and fewer possible post-translational modifications in microbes provide a unique opportunity to comprehensively characterize their dynamic proteomes. We have constructed a PeptideAtlas (PA) covering 62.7% of the predicted proteome of the extremely halophilic archaeon Halobacterium salinarum NRC-1 by compiling approximately 636 000 tandem mass spectra from 497 mass spectrometry runs in 88 experiments. Analysis of the PA with respect to biophysical properties of constituent peptides, functional properties of parent proteins of detected peptides, and performance of different mass spectrometry approaches has highlighted plausible strategies for improving proteome coverage and selecting signature peptides for targeted proteomics. Notably, discovery of a significant correlation between absolute abundances of mRNAs and proteins has helped identify low abundance of proteins as the major limitation in peptide detection. Furthermore, we have discovered that iTRAQ labeling for quantitative proteomic analysis introduces a significant bias in peptide detection by mass spectrometry. Therefore, despite identifying at least one proteotypic peptide for almost all proteins in the PA, a context-dependent selection of proteotypic peptides appears to be the most effective approach for targeted proteomics.

  2. Improvement of Predictive Ability by Uniform Coverage of the Target Genetic Space

    PubMed Central

    Bustos-Korts, Daniela; Malosetti, Marcos; Chapman, Scott; Biddulph, Ben; van Eeuwijk, Fred

    2016-01-01

    Genome-enabled prediction provides breeders with the means to increase the number of genotypes that can be evaluated for selection. One of the major challenges in genome-enabled prediction is how to construct a training set of genotypes from a calibration set that represents the target population of genotypes, where the calibration set is composed of a training and validation set. A random sampling protocol of genotypes from the calibration set will lead to low quality coverage of the total genetic space by the training set when the calibration set contains population structure. As a consequence, predictive ability will be affected negatively, because some parts of the genotypic diversity in the target population will be under-represented in the training set, whereas other parts will be over-represented. Therefore, we propose a training set construction method that uniformly samples the genetic space spanned by the target population of genotypes, thereby increasing predictive ability. To evaluate our method, we constructed training sets alongside with the identification of corresponding genomic prediction models for four genotype panels that differed in the amount of population structure they contained (maize Flint, maize Dent, wheat, and rice). Training sets were constructed using uniform sampling, stratified-uniform sampling, stratified sampling and random sampling. We compared these methods with a method that maximizes the generalized coefficient of determination (CD). Several training set sizes were considered. We investigated four genomic prediction models: multi-locus QTL models, GBLUP models, combinations of QTL and GBLUPs, and Reproducing Kernel Hilbert Space (RKHS) models. For the maize and wheat panels, construction of the training set under uniform sampling led to a larger predictive ability than under stratified and random sampling. The results of our methods were similar to those of the CD method. For the rice panel, all training set construction

  3. Use of radiation protraction to escalate biologically effective dose to the treatment target

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuperman, V. Y.; Spradlin, G. S.; Department of Mathematics, Embry-Riddle University, Daytona Beach, Florida 32114

    2011-12-15

    Purpose: The aim of this study is to evaluate how simultaneously increasing fraction time and dose per fraction affect biologically effective dose for the target (BED{sub tar}) while biologically effective dose for the normal tissue (BED{sub nt}) is fixed. Methods: In this investigation, BED{sub tar} and BED{sub nt} were studied by assuming mono-exponential repair of sublethal damage with tissue dependent repair half-time. Results: Our results demonstrate that under certain conditions simultaneously increasing fraction time and dose per fraction result in increased BED{sub tar} while BED{sub nt} is fixed. The dependence of biologically effective dose on fraction time is influenced bymore » the dose rate. In this investigation we analytically determined time-varying dose rate R-tilde which minimizes BED. Changes in BED with fraction time were compared for constant dose rate and for R-tilde. Conclusions: A number of recent experimental and theoretical studies have demonstrated that slow delivery of radiation (known as radiation protraction) leads to reduced therapeutic effect because of increased repair of sublethal damage. In contrast, our analysis shows that under certain conditions simultaneously increasing fraction time and dose per fraction are radiobiologically advantageous.« less

  4. Vaccine vial stopper performance for fractional dose delivery of vaccines.

    PubMed

    Jarrahian, Courtney; Myers, Daniel; Creelman, Ben; Saxon, Eugene; Zehrung, Darin

    2017-07-03

    Shortages of vaccines such as inactivated poliovirus and yellow fever vaccines have been addressed by administering reduced-or fractional-doses, as recommended by the World Health Organization Strategic Advisory Group of Experts on Immunization, to expand population coverage in countries at risk. We evaluated 3 kinds of vaccine vial stoppers to assess their performance after increased piercing from repeated withdrawal of doses needed when using fractional doses (0.1 mL) from presentations intended for full-dose (0.5 mL) delivery. Self-sealing capacity and fragmentation of the stopper were assessed via modified versions of international standard protocols. All stoppers maintained self-sealing capacity after 100 punctures. The damage to stoppers measured as the fragmentation rate was within the target of ≤ 10% of punctures resulting in a fragment after as many as 50 punctures. We concluded that stopper failure is not likely to be a concern if existing vaccine vials containing up to 10 regular doses are used up to 50 times for fractional dose delivery.

  5. Vaccine vial stopper performance for fractional dose delivery of vaccines

    PubMed Central

    Jarrahian, Courtney; Myers, Daniel; Creelman, Ben; Saxon, Eugene; Zehrung, Darin

    2017-01-01

    ABSTRACT Shortages of vaccines such as inactivated poliovirus and yellow fever vaccines have been addressed by administering reduced—or fractional—doses, as recommended by the World Health Organization Strategic Advisory Group of Experts on Immunization, to expand population coverage in countries at risk. We evaluated 3 kinds of vaccine vial stoppers to assess their performance after increased piercing from repeated withdrawal of doses needed when using fractional doses (0.1 mL) from presentations intended for full-dose (0.5 mL) delivery. Self-sealing capacity and fragmentation of the stopper were assessed via modified versions of international standard protocols. All stoppers maintained self-sealing capacity after 100 punctures. The damage to stoppers measured as the fragmentation rate was within the target of ≤ 10% of punctures resulting in a fragment after as many as 50 punctures. We concluded that stopper failure is not likely to be a concern if existing vaccine vials containing up to 10 regular doses are used up to 50 times for fractional dose delivery. PMID:28463054

  6. Is high–dose rate RapidArc-based radiosurgery dosimetrically advantageous for the treatment of intracranial tumors?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Bo; Yang, Yong, E-mail: yangy2@upmc.edu; Li, Xiang

    In linac-based stereotactic radiosurgery (SRS) and radiotherapy (SRT), circular cone(s) or conformal arc(s) are conventionally used to treat intracranial lesions. However, when the target is in close proximity to critical structures, it is frequently quite challenging to generate a quality plan using these techniques. In this study, we investigated the dosimetric characteristics of using high–dose rate RapidArc (RA) technique for radiosurgical treatment of intracranial lesions. A total of 10 intracranial SRS/SRT cases previously planned using dynamic conformal arc (DCA) or cone-based techniques have been included in this study. For each case, 3 treatment plans were generated: (1) a DCA planmore » with multiple noncoplanar arcs, (2) a high–dose rate RA plan with arcs oriented the same as DCA (multiple-arc RA), and 3) a high–dose rate RA plan with a single coplanar arc (single-arc RA). All treatment plans were generated under the same prescription and similar critical structure dose limits. Plan quality for different plans was evaluated by comparing various dosimetric parameters such as target coverage, conformity index (CI), homogeneity index (HI), critical structures, and normal brain tissue doses as well as beam delivery time. With similar critical structure sparing, high–dose rate RA plans can achieve much better target coverage, dose conformity, and dose homogeneity than the DCA plans can. Plan quality indices CI and HI, for the DCA, multiple-arc RA, and single-arc RA techniques, were measured as 1.67 ± 0.39, 1.32 ± 0.28, and 1.38 ± 0.30 and 1.24 ± 0.11, 1.10 ± 0.04, and 1.12 ± 0.07, respectively. Normal brain tissue dose (V{sub 12} {sub Gy}) was found to be similar for DCA and multiple-arc RA plans but much larger for the single-arc RA plans. Beam delivery was similar for DCA and multiple-arc RA plans but shorter with single-arc RA plans. Multiple-arc RA SRS/SRT can provide better treatment plans than conventional DCA plans, especially for

  7. Low Z target switching to increase tumor endothelial cell dose enhancement during gold nanoparticle-aided radiation therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berbeco, Ross I., E-mail: rberbeco@partners.org; Detappe, Alexandre; Tsiamas, Panogiotis

    2016-01-15

    Purpose: Previous studies have introduced gold nanoparticles as vascular-disrupting agents during radiation therapy. Crucial to this concept is the low energy photon content of the therapy radiation beam. The authors introduce a new mode of delivery including a linear accelerator target that can toggle between low Z and high Z targets during beam delivery. In this study, the authors examine the potential increase in tumor blood vessel endothelial cell radiation dose enhancement with the low Z target. Methods: The authors use Monte Carlo methods to simulate delivery of three different clinical photon beams: (1) a 6 MV standard (Cu/W) beam,more » (2) a 6 MV flattening filter free (Cu/W), and (3) a 6 MV (carbon) beam. The photon energy spectra for each scenario are generated for depths in tissue-equivalent material: 2, 10, and 20 cm. The endothelial dose enhancement for each target and depth is calculated using a previously published analytic method. Results: It is found that the carbon target increases the proportion of low energy (<150 keV) photons at 10 cm depth to 28% from 8% for the 6 MV standard (Cu/W) beam. This nearly quadrupling of the low energy photon content incident on a gold nanoparticle results in 7.7 times the endothelial dose enhancement as a 6 MV standard (Cu/W) beam at this depth. Increased surface dose from the low Z target can be mitigated by well-spaced beam arrangements. Conclusions: By using the fast-switching target, one can modulate the photon beam during delivery, producing a customized photon energy spectrum for each specific situation.« less

  8. TU-H-BRC-06: Temperature Simulation of Tungsten and W25Re Targets to Deliver High Dose Rate 10 MV Photons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, J; Trovati, S; Loo, B

    Purpose: To study the impact of electron beam size, target thickness, and target temperature on the ability of the flattening filter-free mode (FFF) treatment head to deliver high-dose-rate irradiations. Methods: The dose distribution and transient temperature of the X-ray target under 10 MeV electron beam with pulse length of 5 microseconds, and repetition rate of 1000 Hz was studied. A MCNP model was built to calculate the percentage depth dose (PPD) distribution in a water phantom at a distance of 100 cm. ANSYS software was used to run heat transfer simulations. The PPD and temperature for both tungsten and W25Remore » targets for different electron beam sizes (FHWM 0.2, 0.5, 1 and 2 mm) and target thickness (0.2 to 2 mm) were studied. Results: Decreasing the target thickness from 1 mm to 0.5 mm, caused a surface dose increase about 10 percent. For both target materials, the peak temperature was about 1.6 times higher for 0.5 mm electron beam compared to the 1 mm beam after reaching their equilibrium. For increasing target thicknesses, the temperature rise caused by the first pulse is similar for all thicknesses, however the temperature difference for subsequent pulses becomes larger until a constant ratio is reached. The target peak temperature after reaching equilibrium can be calculated by adding the steady state temperature and the amplitude of the temperature oscillation. Conclusion: This work indicates the potential to obtain high dose rate irradiation by selecting target material, geometry and electron beam parameters. W25Re may not outperformed tungsten when the target is thick due to its relatively low thermal conductivity. The electron beam size only affects the target temperature but not the PPD. Thin target is preferred to obtain high dose rate and low target temperature, however, the resulting high surface dose is a major concern. NIH funding:R21 EB015957-01; DOD funding:W81XWH-13-1-0165 BL, PM, PB, and RF are founders of TibaRay, Inc. BL is also

  9. Potential implications of the bystander effect on TCP and EUD when considering target volume dose heterogeneity.

    PubMed

    Balderson, Michael J; Kirkby, Charles

    2015-01-01

    In light of in vitro evidence suggesting that radiation-induced bystander effects may enhance non-local cell killing, there is potential for impact on radiotherapy treatment planning paradigms such as the goal of delivering a uniform dose throughout the clinical target volume (CTV). This work applies a bystander effect model to calculate equivalent uniform dose (EUD) and tumor control probability (TCP) for external beam prostate treatment and compares the results with a more common model where local response is dictated exclusively by local absorbed dose. The broad assumptions applied in the bystander effect model are intended to place an upper limit on the extent of the results in a clinical context. EUD and TCP of a prostate cancer target volume under conditions of increasing dose heterogeneity were calculated using two models: One incorporating bystander effects derived from previously published in vitro bystander data ( McMahon et al. 2012 , 2013a); and one using a common linear-quadratic (LQ) response that relies exclusively on local absorbed dose. Dose through the CTV was modelled as a normal distribution, where the degree of heterogeneity was then dictated by changing the standard deviation (SD). Also, a representative clinical dose distribution was examined as cold (low dose) sub-volumes were systematically introduced. The bystander model suggests a moderate degree of dose heterogeneity throughout a target volume will yield as good or better outcome compared to a uniform dose in terms of EUD and TCP. For a typical intermediate risk prostate prescription of 78 Gy over 39 fractions maxima in EUD and TCP as a function of increasing SD occurred at SD ∼ 5 Gy. The plots only dropped below the uniform dose values for SD ∼ 10 Gy, almost 13% of the prescribed dose. Small, but potentially significant differences in the outcome metrics between the models were identified in the clinically-derived dose distribution as cold sub-volumes were introduced. In terms of

  10. HPV Vaccination Coverage of Male Adolescents in the United States

    PubMed Central

    Lu, Peng-jun; Yankey, David; Jeyarajah, Jenny; O’Halloran, Alissa; Elam-Evans, Laurie D.; Smith, Philip J.; Stokley, Shannon; Singleton, James A.; Dunne, Eileen F.

    2018-01-01

    Background In 2011, the Advisory Committee for Immunization Practices (ACIP) recommended routine use HPV vaccine for male adolescents. Methods We used the 2013 National Immunization Survey-Teen (NIS-Teen) data to assess HPV vaccine uptake (≥1 dose) and series completion (≥3 doses). Multivariable logistic regression analysis and a predictive marginal model were conducted to identify independent predictors of vaccination among adolescent males aged 13–17 years. Results HPV vaccination coverage with ≥1 dose was 34.6% while series completion (≥3 doses) was 13.9%. Coverage was significantly higher among non-Hispanic blacks and Hispanics compared with non-Hispanic white males. Multivariable logistic regression showed that characteristics independently associated with a higher likelihood of HPV vaccination (≥1 dose) included: being non-Hispanic black race or Hispanic ethnicity, having mothers who were widowed, divorced, or separated, having 1–3 physician contacts in the past 12 months, a well-child visit at age 11–12 years, having one or two vaccination providers, living in urban or suburban areas, and receiving vaccinations from more than one type of facility (p<0.05). Having mothers with some college or college education, having a higher family income to poverty ratio, living in South or Midwest, and receiving vaccinations from all STD/school/teen clinics or other facilities were independently associated with a lower likelihood of HPV vaccination (p<0.05). Conclusions Following recommendations for routine HPV vaccination among male adolescents, uptake in 2013 was low in males. Increased efforts are needed to improve vaccination coverage, especially for those who are least likely to be vaccinated. PMID:26504124

  11. The ciprofloxacin target AUC : MIC ratio is not reached in hospitalized patients with the recommended dosing regimens.

    PubMed

    Haeseker, Michiel; Stolk, Leo; Nieman, Fred; Hoebe, Christian; Neef, Cees; Bruggeman, Cathrien; Verbon, Annelies

    2013-01-01

    The aim of this study was to determine the ciprofloxacin serum concentrations in hospitalized patients and to determine which percentage reached the efficacy target of AUC : MIC > 125. Additionally, the influence of demographic anthropomorphic and clinical parameters on the pharmacokinetics and pharmacodynamics of ciprofloxacin were investigated. In serum of 80 hospitalized patients ciprofloxacin concentrations were measured with reverse phase high performance liquid chromatography with fluorescence detection. The ciprofloxacin dose was 400-1200 mg day(-1) i.v. in two or three doses depending on renal function and causative bacteria. Pharmacokinetic parameters were calculated with maximum a posteriori Bayesian estimation (MW\\PHARM 3.60). A two compartment open model was used. Mean (± SD) age was 66 (± 17) years, the mean clearance corrected for bodyweight was 0.24 l h(-1) kg(-1) and the mean AUC was 49 mg l(-1) h. Ciprofloxacin clearance and thus AUC were associated with both age and serum creatinine. Of all patients, 21% and 75% of the patients, did not reach the proposed ciprofloxacin AUC : MIC > 125 target with MICs of 0.25 and 0.5 mg l(-1), respectively. A computer simulated increase in the daily dose from 800 mg to 1200 mg, decreased these percentages to 1% and 37%, respectively. A substantial proportion of the hospitalized patients did not reach the target ciprofloxacin AUC : MIC and are suboptimally dosed with recommended doses. Taking into account the increasing resistance to ciprofloxacin worldwide, a ciprofloxacin dose of 1200 mg i.v. daily in patients with normal renal function is necessary to reach the targeted AUC : MIC > 125. © 2012 The Authors. British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.

  12. SU-F-19A-12: Split-Ring Applicator with Interstitial Needle for Improved Volumetric Coverage in HDR Brachytherapy for Cervical Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sherertz, T; Ellis, R; Colussi, V

    2014-06-15

    Purpose: To evaluate volumetric coverage of a Mick Radionuclear titanium Split-Ring applicator (SRA) with/without interstitial needle compared to an intracavitary Vienna applicator (VA), interstitial-intracavitary VA, and intracavitary ring and tandem applicator (RTA). Methods: A 57 year-old female with FIGO stage IIB cervical carcinoma was treated following chemoradiotherapy (45Gy pelvic and 5.4Gy parametrial boost) with highdose- rate (HDR) brachytherapy to 30Gy in 5 fractions using a SRA. A single interstitial needle was placed using the Ellis Interstitial Cap for the final three fractions to increase coverage of left-sided gross residual disease identified on 3T-MRI. High-risk (HR) clinical target volume (CTV) andmore » intermediate-risk (IR) CTV were defined using axial T2-weighted 2D and 3D MRI sequences (Philips PET/MRI unit). Organs-at-risks (OARs) were delineated on CT. Oncentra planning system was used for treatment optimization satisfying GEC-ESTRO guidelines for target coverage and OAR constraints. Retrospectively, treatment plans (additional 20 plans) were simulated using intracavitary SRA (without needle), intracavitary VA (without needle), interstitial-intracavitary VA, and intracavitary RTA with this same patient case. Plans were optimized for each fraction to maintain coverage to HR-CTV. Results: Interstitial-intracavitary SRA achieved the following combined coverage for external radiation and brachytherapy (EQD2): D90 HR-CTV =94.6Gy; Bladder-2cc =88.9Gy; Rectum-2cc =65.1Gy; Sigmoid-2cc =48.9Gy; Left vaginal wall (VW) =103Gy, Right VW =99.2Gy. Interstitial-intracavitary VA was able to achieve identical D90 HR-CTV =94.6Gy, yet Bladder-2cc =91.9Gy (exceeding GEC-ESTRO recommendations of 2cc<90Gy) and Left VW =120.8Gy and Right VW =115.5Gy. Neither the SRA nor VA without interstitial needle could cover HR-CTV adequately without exceeding dose to Bladder-2cc. Conventional RTA was unable to achieve target coverage for the HR-CTV >80Gy without severely

  13. Toward Prostate Cancer Contouring Guidelines on Magnetic Resonance Imaging: Dominant Lesion Gross and Clinical Target Volume Coverage Via Accurate Histology Fusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gibson, Eli; Biomedical Engineering, University of Western Ontario, London, Ontario; Centre for Medical Image Computing, University College London, London

    Purpose: Defining prostate cancer (PCa) lesion clinical target volumes (CTVs) for multiparametric magnetic resonance imaging (mpMRI) could support focal boosting or treatment to improve outcomes or lower morbidity, necessitating appropriate CTV margins for mpMRI-defined gross tumor volumes (GTVs). This study aimed to identify CTV margins yielding 95% coverage of PCa tumors for prospective cases with high likelihood. Methods and Materials: Twenty-five men with biopsy-confirmed clinical stage T1 or T2 PCa underwent pre-prostatectomy mpMRI, yielding T2-weighted, dynamic contrast-enhanced, and apparent diffusion coefficient images. Digitized whole-mount histology was contoured and registered to mpMRI scans (error ≤2 mm). Four observers contoured lesion GTVs onmore » each mpMRI scan. CTVs were defined by isotropic and anisotropic expansion from these GTVs and from multiparametric (unioned) GTVs from 2 to 3 scans. Histologic coverage (proportions of tumor area on co-registered histology inside the CTV, measured for Gleason scores [GSs] ≥6 and ≥7) and prostate sparing (proportions of prostate volume outside the CTV) were measured. Nonparametric histologic-coverage prediction intervals defined minimal margins yielding 95% coverage for prospective cases with 78% to 92% likelihood. Results: On analysis of 72 true-positive tumor detections, 95% coverage margins were 9 to 11 mm (GS ≥ 6) and 8 to 10 mm (GS ≥ 7) for single-sequence GTVs and were 8 mm (GS ≥ 6) and 6 mm (GS ≥ 7) for 3-sequence GTVs, yielding CTVs that spared 47% to 81% of prostate tissue for the majority of tumors. Inclusion of T2-weighted contours increased sparing for multiparametric CTVs with 95% coverage margins for GS ≥6, and inclusion of dynamic contrast-enhanced contours increased sparing for GS ≥7. Anisotropic 95% coverage margins increased the sparing proportions to 71% to 86%. Conclusions: Multiparametric magnetic resonance imaging–defined GTVs expanded by appropriate

  14. A novel two-step optimization method for tandem and ovoid high-dose-rate brachytherapy treatment for locally advanced cervical cancer.

    PubMed

    Sharma, Manju; Fields, Emma C; Todor, Dorin A

    2015-01-01

    To present a novel method allowing fast volumetric optimization of tandem and ovoid high-dose-rate treatments and to quantify its benefits. Twenty-seven CT-based treatment plans from 6 consecutive cervical cancer patients treated with four to five intracavitary tandem and ovoid insertions were used. Initial single-step optimized plans were manually optimized, approved, and delivered plans created with a goal to cover high-risk clinical target volume (HR-CTV) with D90 >90% and minimize rectum, bladder, and sigmoid D2cc. For the two-step optimized (TSO) plan, each single-step optimized plan was replanned adding a structure created from prescription isodose line to the existent physician delineated HR-CTV, rectum, bladder, and sigmoid. New, more rigorous dose-volume histogram constraints for the critical organs at risks (OARs) were used for the optimization. HR-CTV D90 and OAR D2ccs were evaluated in both plans. TSO plans had consistently smaller D2ccs for all three OARs while preserving HR-CTV D90. On plans with "excellent" CTV coverage, average D90 of 96% (91-102%), sigmoid, bladder, and rectum D2cc, respectively, reduced on average by 37% (16-73%), 28% (20-47%), and 27% (15-45%). Similar reductions were obtained on plans with "good" coverage, average D90 of 93% (90-99%). For plans with "inferior" coverage, average D90 of 81%, the coverage increased to 87% with concurrent D2cc reductions of 31%, 18%, and 11% for sigmoid, bladder, and rectum, respectively. The TSO can be added with minimal planning time increase but with the potential of dramatic and systematic reductions in OAR D2ccs and in some cases with concurrent increase in target dose coverage. These single-fraction modifications would be magnified over the course of four to five intracavitary insertions and may have real clinical implications in terms of decreasing both acute and late toxicities. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  15. Esophageal cancer dose escalation using a simultaneous integrated boost technique.

    PubMed

    Welsh, James; Palmer, Matthew B; Ajani, Jaffer A; Liao, Zhongxing; Swisher, Steven G; Hofstetter, Wayne L; Allen, Pamela K; Settle, Steven H; Gomez, Daniel; Likhacheva, Anna; Cox, James D; Komaki, Ritsuko

    2012-01-01

    We previously showed that 75% of radiation therapy (RT) failures in patients with unresectable esophageal cancer are in the gross tumor volume (GTV). We performed a planning study to evaluate if a simultaneous integrated boost (SIB) technique could selectively deliver a boost dose of radiation to the GTV in patients with esophageal cancer. Treatment plans were generated using four different approaches (two-dimensional conformal radiotherapy [2D-CRT] to 50.4 Gy, 2D-CRT to 64.8 Gy, intensity-modulated RT [IMRT] to 50.4 Gy, and SIB-IMRT to 64.8 Gy) and optimized for 10 patients with distal esophageal cancer. All plans were constructed to deliver the target dose in 28 fractions using heterogeneity corrections. Isodose distributions were evaluated for target coverage and normal tissue exposure. The 50.4 Gy IMRT plan was associated with significant reductions in mean cardiac, pulmonary, and hepatic doses relative to the 50.4 Gy 2D-CRT plan. The 64.8 Gy SIB-IMRT plan produced a 28% increase in GTV dose and comparable normal tissue doses as the 50.4 Gy IMRT plan; compared with the 50.4 Gy 2D-CRT plan, the 64.8 Gy SIB-IMRT produced significant dose reductions to all critical structures (heart, lung, liver, and spinal cord). The use of SIB-IMRT allowed us to selectively increase the dose to the GTV, the area at highest risk of failure, while simultaneously reducing the dose to the normal heart, lung, and liver. Clinical implications warrant systematic evaluation. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Esophageal Cancer Dose Escalation using a Simultaneous Integrated Boost Technique

    PubMed Central

    Welsh, James; Palmer, Matthew B.; Ajani, Jaffer A.; Liao, Zhongxing; Swisher, Steven G.; Hofstetter, Wayne L.; Allen, Pamela K.; Settle, Steven H.; Gomez, Daniel; Likhacheva, Anna; Cox, James D.; Komaki, Ritsuko

    2014-01-01

    Purpose We previously showed that 75% of radiation therapy (RT) failures in patients with unresectable esophageal cancer are in the gross tumor volume (GTV). We performed a planning study to evaluate if a simultaneous integrated boost (SIB) technique could selectively deliver a boost dose of radiation to the GTV in patients with esophageal cancer. Methods and Materials Treatment plans were generated using four different approaches (two-dimensional conformal RT [2D-CRT] to 50.4 Gy or 64.8 Gy, intensity-modulated RT [IMRT] to 50.4 Gy, and SIB-IMRT to 64.8 Gy) and optimized for 10 patients with distal esophageal cancer. All plans were constructed to deliver the target dose in 28 fractions using heterogeneity corrections. Isodose distributions were evaluated for target coverage and normal tissue exposure. Results The 50.4-Gy IMRT plan was associated with significant reductions in mean cardiac, pulmonary, and hepatic doses relative to the 50.4-Gy 2D-CRT plan. The 64.8-Gy SIB-IMRT plan produced a 28% increase in GTV dose and the same normal tissue doses as the 50.4-Gy IMRT plan; compared with the 50.4-Gy 2D-CRT plan, the 64.8-Gy SIB-IMRT produced significant dose reductions to all critical structures (heart, lung, liver, and spinal cord). Conclusions The use of SIB-IMRT allowed us to selectively increase the dose to the GTV, the area at highest risk of failure, while simultaneously reducing the dose to the normal heart, lung, and liver. Clinical implications warrant systematic evaluation. PMID:21123005

  17. SU-E-T-232: Custom High-Dose-Rate Brachytherapy Surface Mold Applicators: The Importance Source to Skin Distance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, S; Demanes, J; Kamrava, M

    2015-06-15

    Purpose: Surface mold applicators can be customized to fit irregular skin surfaces that are difficult to treat with other radiation therapy techniques. Optimal design of customized HDR skin brachytherapy is not well-established. We evaluated the impact of applicator thickness (source to skin distance) on target dosimetry. Methods: 27 patients had 34 treated sites: scalp 4, face 13, extremity 13, and torso 4. Custom applicators were constructed from 5–15 mm thick thermoplastic bolus molded over the skin lesion. A planar array of plastic brachytherapy catheters spaced 5–10 mm apart was affixed to the bolus. CT simulation was used to contour themore » target volume and to determine the prescription depth. Inverse planning simulated annealing followed by graphical optimization was used to plan and deliver 40–56 Gy in 8–16 fractions. Target coverage parameters (D90, Dmean, and V100) and dose uniformity (V110–200, D0.1cc, D1cc, and D2cc) were studied according to target depth (<5mm vs. ≥5mm) and applicator thickness (5–10mm vs. ≥10mm). Results: The average prescription depth was 4.2±1.5mm. The average bolus thickness was 9.2±2.4mm. The median CTV volume was 10.0 cc (0.2–212.4 cc). Similar target coverage was achieved with prescription depths of <5mm and ≥5mm (Dmean = 113.8% vs. 112.4% and D90 = 100.2% vs. 98.3%). The <5mm prescription depth plans were more uniform (D0.1cc = 131.8% vs. 151.8%). Bolus thickness <10mm vs. ≥10mm plans also had similar target coverage (Dmean = 118.2% vs. 110.7% and D90 = 100.1% vs. 99.0%). Applicators ≥10mm thick, however, provide more uniform target dosimetry (D0.1cc = 146.9% vs. 139.5%). Conclusion: Prescription depth is based upon the thickness of the lesion and upon the clinical needs of the patient. Applicators ≥10mm thick provide more dose uniformity than 5–10mm thick applicators. Applicator thickness is an important variable that should be considered during treatment planning to achieve optimal dose

  18. Coverage of childhood vaccination among children aged 12-23 months, Tamil Nadu, 2015, India

    PubMed Central

    Murhekar, Manoj V.; Kamaraj, P.; Kanagasabai, K.; Elavarasu, G.; Rajasekar, T. Daniel; Boopathi, K.; Mehendale, Sanjay

    2017-01-01

    Background & objectives: District-Level Household Survey-4 (DLHS-4) indicated that during 2012-2013, only 56 per cent of children aged 12-23 months in Tamil Nadu were fully vaccinated, which were lesser than those reported in earlier national surveys. We, therefore, conducted cluster surveys to estimate coverage of childhood vaccination in the State, and also to identify the factors associated with low coverage. Methods: Cross-sectional surveys were conducted in 15 strata [municipal corporation non-slum (n=1), municipal corporation slum (n=1), hilly (n=1), rural (n=6) and urban (n=6)]. From each stratum, 30 clusters were selected using probability proportional to the population size linear systematic sampling; seven children aged 12-23 months were selected from each cluster and their mothers/care-takers were interviewed to collect information about vaccination status of the child. A child was considered fully vaccinated if he/she received bacillus Calmette-Guérin (BCG), three doses of pentavalent, three doses of oral polio vaccine and one dose of measles vaccine, and appropriately vaccinated if all vaccine doses were given at right age and with right interval. Further, coverage of fully vaccinated children (FVC) as per vaccination cards or mothers’ recall, validated coverage of FVC (V-FVC) among those having cards, and coverage of appropriately vaccinated children (AVC) were estimated using survey data analysis module with appropriate sampling weights. Results: A total of 3150 children were surveyed, of them 2528 (80.3%) had vaccination card. The weighted coverage of FVC, V-FVC and AVC in the State was 79.9 per cent [95% confidence interval (CI): 78.2-81.5], 78.8 per cent (95% CI: 76.9-80.5) and 69.7 per cent (95% CI: 67.7-71.7), respectively. The coverage of individual vaccine ranged between 84 per cent (measles) and 99.8 per cent (BCG). About 12 per cent V-FVC were not vaccinated as per the vaccination schedule. Interpretation & conclusions: The coverage of

  19. Poster - 56: Preliminary comparison of FF- and FFF-VMAT for prostate plans with higher rectal dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Baochang; Darko, Johnson; Osei, Ernest

    2016-08-15

    Purpose: A recent retrospective study found 53 patients previously treated to 78Gy/39 using flattened filtered (FF) 6X-VMAT at GRRCC had rectal DVH more than one standard deviation higher than the average. This study was to investigate if using 6FFFor10FFF beams could reduce these DVHs without compromising target coverage. Methods: Twenty patients’ plans were re-planed with 2-arc 6X-VMAT, 6FFF-VMAT and 10FFF-VMAT using the Eclipse TPS following departmental protocol. All plans had the same optimization and normalization, and were evaluated against the acceptance criteria from the QUANTEC and Emami. Statistical differences in the mean dose to OARs (D{sub m}) and PTV homogeneitymore » index (HI) between energies were tested using the paired sample Wilcoxon signed rank statistical method (p<0.05). Beam delivery accuracy was checked on five patients using portal dosimetry (PD). Results: The PTV HI for the 10FFF shows no statistical difference from the 6X. All the OARs, except left femoral head with 6FFF, have significantly lower Dm using 6FFF and 10FFF .There is no difference in the maximum doses to rectum and bladder and are limited by the prescribed doses. Measurements show good agreements in the gamma evaluation (3%/3mm) for all energies. Conclusion: This preliminary study shows that doses to the OARs are reduced using 10FFF for the same target coverage. The plans using 6FFF result in lower doses to some OARs, and statistically different PTV HI. All plans showed very good agreement with measurements.« less

  20. Immunisation coverage of adults: a vaccination counselling campaign in the pharmacies in Switzerland.

    PubMed

    Valeri, Fabio; Hatz, Christoph; Jordan, Dominique; Leuthold, Claudine; Czock, Astrid; Lang, Phung

    2014-01-01

    To assess vaccination coverage for adults living in Switzerland. Through a media campaign, the general population was invited during 1 month to bring their vaccination certificates to the pharmacies to have their immunisation status evaluated with the software viavac©, and to complete a questionnaire. A total of 496 pharmacies in Switzerland participated in the campaign, of which 284 (57%) submitted valid vaccination information. From a total of 3,634 participants in the campaign, there were 3,291 valid cases (participants born ≤ 1992) and 1,011 questionnaires completed. Vaccination coverage for the participants was 45.9% and 34.6% for five and six doses of diphtheria, 56.4% and 44.0% for tetanus and 66.3% and 48.0% for polio, respectively. Coverage estimates for one and two doses of measles vaccine were 76.5% and 49.4%, respectively, for the birth cohort 1967-1992 and 4.0% and 0.8%, respectively, for the cohort ≤ 1966. There was a significant difference in coverage for most vaccinations between the two aforementioned birth cohorts. A plot of the measles vaccine coverage over time shows that the increase in coverage correlated with policy changes in the Swiss Immunisation Schedule. Despite selection bias and low participation, this study indicates that vaccination coverage for the basic recommended immunisations in the adult population in Switzerland is suboptimal. More efforts using various means and methods are needed to increase immunisation coverage in adolescents before they leave school. An established method to determine vaccination coverage for the general population could provide invaluable insights into the effects of changes in vaccination policies and disease outbreaks.

  1. Prospective validation of a novel IV busulfan fixed dosing for paediatric patients to improve therapeutic AUC targeting without drug monitoring.

    PubMed

    Vassal, G; Michel, G; Espérou, H; Gentet, J C; Valteau-Couanet, D; Doz, F; Mechinaud, F; Galambrun, C; Neven, B; Zouabi, H; Nguyen, L; Puozzo, C

    2008-01-01

    Oral busulfan clearance is age-dependent and children experience a wide variability in plasma exposure. BSA- or age-based dosing is used with therapeutic drug monitoring (TDM) to reduce this variability. A new intravenous (IV) dosing of busulfan (Bu) based on body weight, designed to improve AUC targeting without TDM and dose-adjustment, was prospectively evaluated. Bu was administered as a 2 h IV infusion every 6 h over 4 days (16 administrations). Five dose levels were defined on body weight as follows: 1.0 mg/kg for <9 kg; 1.2 mg/kg for 9 to <16 kg; 1.1 mg/kg for 16-23 kg; 0.95 mg/kg for >23-34 kg; 0.80 mg/kg for >34 kg. Bu treatment was followed by Cyclophosphamide or Melphalan prior to allogeneic or autologous transplantation in 55 children aged 0.3-17.2 years (median 5.6 years). No difference in AUC values was observed between weight strata (mean +/- SD 1248 +/- 205 micromol.min), whereas a significant difference in Bu clearance was demonstrated. This new dosing enabled to achieve a mean exposure comparable to that in adults. At dose 1, 91% of patients achieved the targeted AUC range (900-1500 micromol.min) while no patients were underexposed. At doses 9 and 13, over 75% of patients remained within that target whilst most of the others were slightly above. Successful engraftment was achieved in all patients. In conclusion, from infants to adults this new dosing enabled, without TDM and dose adjustment, to successfully target a therapeutic AUC window.

  2. Clustered lot quality assurance sampling to assess immunisation coverage: increasing rapidity and maintaining precision.

    PubMed

    Pezzoli, Lorenzo; Andrews, Nick; Ronveaux, Olivier

    2010-05-01

    Vaccination programmes targeting disease elimination aim to achieve very high coverage levels (e.g. 95%). We calculated the precision of different clustered lot quality assurance sampling (LQAS) designs in computer-simulated surveys to provide local health officers in the field with preset LQAS plans to simply and rapidly assess programmes with high coverage targets. We calculated sample size (N), decision value (d) and misclassification errors (alpha and beta) of several LQAS plans by running 10 000 simulations. We kept the upper coverage threshold (UT) at 90% or 95% and decreased the lower threshold (LT) progressively by 5%. We measured the proportion of simulations with < or =d individuals unvaccinated or lower if the coverage was set at the UT (pUT) to calculate beta (1-pUT) and the proportion of simulations with >d unvaccinated individuals if the coverage was LT% (pLT) to calculate alpha (1-pLT). We divided N in clusters (between 5 and 10) and recalculated the errors hypothesising that the coverage would vary in the clusters according to a binomial distribution with preset standard deviations of 0.05 and 0.1 from the mean lot coverage. We selected the plans fulfilling these criteria: alpha < or = 5% beta < or = 20% in the unclustered design; alpha < or = 10% beta < or = 25% when the lots were divided in five clusters. When the interval between UT and LT was larger than 10% (e.g. 15%), we were able to select precise LQAS plans dividing the lot in five clusters with N = 50 (5 x 10) and d = 4 to evaluate programmes with 95% coverage target and d = 7 to evaluate programmes with 90% target. These plans will considerably increase the feasibility and the rapidity of conducting the LQAS in the field.

  3. Towards universal health coverage: the role of within-country wealth-related inequality in 28 countries in sub-Saharan Africa.

    PubMed

    Hosseinpoor, Ahmad Reza; Victora, Cesar G; Bergen, Nicole; Barros, Aluisio J D; Boerma, Ties

    2011-12-01

    To measure within-country wealth-related inequality in the health service coverage gap of maternal and child health indicators in sub-Saharan Africa and quantify its contribution to the national health service coverage gap. Coverage data for child and maternal health services in 28 sub-Saharan African countries were obtained from the 2000-2008 Demographic Health Survey. For each country, the national coverage gap was determined for an overall health service coverage index and select individual health service indicators. The data were then additively broken down into the coverage gap in the wealthiest quintile (i.e. the proportion of the quintile lacking a required health service) and the population attributable risk (an absolute measure of within-country wealth-related inequality). In 26 countries, within-country wealth-related inequality accounted for more than one quarter of the national overall coverage gap. Reducing such inequality could lower this gap by 16% to 56%, depending on the country. Regarding select individual health service indicators, wealth-related inequality was more common in services such as skilled birth attendance and antenatal care, and less so in family planning, measles immunization, receipt of a third dose of vaccine against diphtheria, pertussis and tetanus and treatment of acute respiratory infections in children under 5 years of age. The contribution of wealth-related inequality to the child and maternal health service coverage gap differs by country and type of health service, warranting case-specific interventions. Targeted policies are most appropriate where high within-country wealth-related inequality exists, and whole-population approaches, where the health-service coverage gap is high in all quintiles.

  4. Hepatitis B Virus Infection in Indonesia 15 Years After Adoption of a Universal Infant Vaccination Program: Possible Impacts of Low Birth Dose Coverage and a Vaccine-Escape Mutant.

    PubMed

    Purwono, Priyo Budi; Juniastuti; Amin, Mochamad; Bramanthi, Rendra; Nursidah; Resi, Erika Maria; Wahyuni, Rury Mega; Yano, Yoshihiko; Soetjipto; Hotta, Hak; Hayashi, Yoshitake; Utsumi, Takako; Lusida, Maria Inge

    2016-09-07

    A universal hepatitis B vaccination program for infants was adopted in Indonesia in 1997. Before its implementation, the prevalence of hepatitis B surface antigen (HBsAg)-positive individuals in the general population was approximately 5-10%. The study aimed to investigate the hepatitis B virus (HBV) serological status and molecular profile among children, 15 years after adoption of a universal infant vaccination program in Indonesia. According to the Local Health Office data in five areas, the percentages of children receiving three doses of hepatitis B vaccine are high (73.9-94.1%), whereas the birth dose coverage is less than 50%. Among 967 children in those areas, the seropositive rate of HBsAg in preschool- and school-aged children ranged from 2.1% to 4.2% and 0% to 5.9%, respectively. Of the 61 HBV DNA-positive samples, the predominant genotype/subtype was B/adw2 Subtype adw3 was identified in genotype C for the first time in this population. Six samples (11.5%) had an amino acid substitution within the a determinant of the S gene region, and one sample had T140I that was suggested as a vaccine-escape mutant type. The low birth dose coverage and the presence of a vaccine-escape mutant might contribute to the endemicity of HBV infection among children in Indonesia. © The American Society of Tropical Medicine and Hygiene.

  5. Hepatitis B Virus Infection in Indonesia 15 Years after Adoption of a Universal Infant Vaccination Program: Possible Impacts of Low Birth Dose Coverage and a Vaccine-Escape Mutant

    PubMed Central

    Purwono, Priyo Budi; Juniastuti; Amin, Mochamad; Bramanthi, Rendra; Nursidah; Resi, Erika Maria; Wahyuni, Rury Mega; Yano, Yoshihiko; Soetjipto; Hotta, Hak; Hayashi, Yoshitake; Utsumi, Takako; Lusida, Maria Inge

    2016-01-01

    A universal hepatitis B vaccination program for infants was adopted in Indonesia in 1997. Before its implementation, the prevalence of hepatitis B surface antigen (HBsAg)–positive individuals in the general population was approximately 5–10%. The study aimed to investigate the hepatitis B virus (HBV) serological status and molecular profile among children, 15 years after adoption of a universal infant vaccination program in Indonesia. According to the Local Health Office data in five areas, the percentages of children receiving three doses of hepatitis B vaccine are high (73.9–94.1%), whereas the birth dose coverage is less than 50%. Among 967 children in those areas, the seropositive rate of HBsAg in preschool- and school-aged children ranged from 2.1% to 4.2% and 0% to 5.9%, respectively. Of the 61 HBV DNA–positive samples, the predominant genotype/subtype was B/adw2. Subtype adw3 was identified in genotype C for the first time in this population. Six samples (11.5%) had an amino acid substitution within the a determinant of the S gene region, and one sample had T140I that was suggested as a vaccine-escape mutant type. The low birth dose coverage and the presence of a vaccine-escape mutant might contribute to the endemicity of HBV infection among children in Indonesia. PMID:27402524

  6. The impact of active breathing control on internal mammary lymph node coverage and normal tissue exposure in breast cancer patients planned for left-sided postmastectomy radiation therapy.

    PubMed

    Barry, Aisling; Rock, Kathy; Sole, Claudio; Rahman, Mohammad; Pintilie, Melania; Lee, Grace; Fyles, Anthony; Koch, C Anne

    The purpose of this study was to evaluate the impact of the active breathing control (ABC) technique on IMN coverage and organs at risk in patients planned for postmastectomy radiation therapy (PMRT), with the inclusion of the internal mammary lymph nodes (IMNs). The effect of body mass index (BMI) on recorded dosimetric parameters was examined in the same patient cohort. Fifty left-sided postmastectomy patients with breast cancer who underwent free-breathing (FB) and ABC-Elekta CT simulation scans were selected at random from an institutional breast cancer database between 2008 and 2014. The ABC plans were directly compared with FB plans from the same patient. The IMN planning target volume coverage met dosimetric criteria for coverage of receiving more than 90% of the prescribed dose (V90) >90%, although it decreased with ABC compared with FB (94.5% vs 98%, P < .001). Overall, ABC significantly reduced doses to all measured heart and left anterior descending coronary artery parameters, ipsilateral lung V20, and mean lung dose compared with FB (P < .001). There was no difference seen between the ABC and FB plans with respect to the dose to contralateral lung or contralateral breast. There was no correlation identified between BMI and any of the dosimetric parameters recorded from the ABC and FB plans. Our results suggest that ABC reduces IMN coverage in left-sided breast cancer patients planned for PMRT; however, dosimetric criteria for IMN coverage were still met, suggesting that this is not likely to be clinically significant. ABC led to significant sparing of organs at risk compared with FB conditions and was not affected by BMI. Collectively, the results support the use of ABC for breast cancer patients undergoing left-sided PMRT requiring regional nodal irradiation that includes the IMNs. Further prospective clinical studies are required to determine the impact of these results on late normal tissue effects. Crown Copyright © 2016. Published by Elsevier Inc

  7. A novel method for the evaluation of uncertainty in dose-volume histogram computation.

    PubMed

    Henríquez, Francisco Cutanda; Castrillón, Silvia Vargas

    2008-03-15

    Dose-volume histograms (DVHs) are a useful tool in state-of-the-art radiotherapy treatment planning, and it is essential to recognize their limitations. Even after a specific dose-calculation model is optimized, dose distributions computed by using treatment-planning systems are affected by several sources of uncertainty, such as algorithm limitations, measurement uncertainty in the data used to model the beam, and residual differences between measured and computed dose. This report presents a novel method to take them into account. To take into account the effect of associated uncertainties, a probabilistic approach using a new kind of histogram, a dose-expected volume histogram, is introduced. The expected value of the volume in the region of interest receiving an absorbed dose equal to or greater than a certain value is found by using the probability distribution of the dose at each point. A rectangular probability distribution is assumed for this point dose, and a formulation that accounts for uncertainties associated with point dose is presented for practical computations. This method is applied to a set of DVHs for different regions of interest, including 6 brain patients, 8 lung patients, 8 pelvis patients, and 6 prostate patients planned for intensity-modulated radiation therapy. Results show a greater effect on planning target volume coverage than in organs at risk. In cases of steep DVH gradients, such as planning target volumes, this new method shows the largest differences with the corresponding DVH; thus, the effect of the uncertainty is larger.

  8. Volumetric-modulated arc therapy for the treatment of a large planning target volume in thoracic esophageal cancer.

    PubMed

    Abbas, Ahmar S; Moseley, Douglas; Kassam, Zahra; Kim, Sun Mo; Cho, Charles

    2013-05-06

    Recently, volumetric-modulated arc therapy (VMAT) has demonstrated the ability to deliver radiation dose precisely and accurately with a shorter delivery time compared to conventional intensity-modulated fixed-field treatment (IMRT). We applied the hypothesis of VMAT technique for the treatment of thoracic esophageal carcinoma to determine superior or equivalent conformal dose coverage for a large thoracic esophageal planning target volume (PTV) with superior or equivalent sparing of organs-at-risk (OARs) doses, and reduce delivery time and monitor units (MUs), in comparison with conventional fixed-field IMRT plans. We also analyzed and compared some other important metrics of treatment planning and treatment delivery for both IMRT and VMAT techniques. These metrics include: 1) the integral dose and the volume receiving intermediate dose levels between IMRT and VMATI plans; 2) the use of 4D CT to determine the internal motion margin; and 3) evaluating the dosimetry of every plan through patient-specific QA. These factors may impact the overall treatment plan quality and outcomes from the individual planning technique used. In this study, we also examined the significance of using two arcs vs. a single-arc VMAT technique for PTV coverage, OARs doses, monitor units and delivery time. Thirteen patients, stage T2-T3 N0-N1 (TNM AJCC 7th edn.), PTV volume median 395 cc (range 281-601 cc), median age 69 years (range 53 to 85), were treated from July 2010 to June 2011 with a four-field (n = 4) or five-field (n = 9) step-and-shoot IMRT technique using a 6 MV beam to a prescribed dose of 50 Gy in 20 to 25 F. These patients were retrospectively replanned using single arc (VMATI, 91 control points) and two arcs (VMATII, 182 control points). All treatment plans of the 13 study cases were evaluated using various dose-volume metrics. These included PTV D99, PTV D95, PTV V9547.5Gy(95%), PTV mean dose, Dmax, PTV dose conformity (Van't Riet conformation number (CN)), mean lung dose

  9. Managing toxicities and optimal dosing of targeted drugs in advanced kidney cancer

    PubMed Central

    Seruga, B.; Gan, H.K.; Knox, J.J.

    2009-01-01

    The toxicities of new, targeted drugs may diminish their effectiveness in advanced kidney cancer if those toxicities are not recognized and properly addressed early in patient treatment. Most of the drug-related toxicities in advanced kidney cancer are manageable with supportive care, obviating a need for long interruptions, dose reductions, or permanent discontinuation of the treatment. PMID:19478903

  10. Volumetric‐modulated arc therapy for the treatment of a large planning target volume in thoracic esophageal cancer

    PubMed Central

    Moseley, Douglas; Kassam, Zahra; Kim, Sun Mo; Cho, Charles

    2013-01-01

    Recently, volumetric‐modulated arc therapy (VMAT) has demonstrated the ability to deliver radiation dose precisely and accurately with a shorter delivery time compared to conventional intensity‐modulated fixed‐field treatment (IMRT). We applied the hypothesis of VMAT technique for the treatment of thoracic esophageal carcinoma to determine superior or equivalent conformal dose coverage for a large thoracic esophageal planning target volume (PTV) with superior or equivalent sparing of organs‐at‐risk (OARs) doses, and reduce delivery time and monitor units (MUs), in comparison with conventional fixed‐field IMRT plans. We also analyzed and compared some other important metrics of treatment planning and treatment delivery for both IMRT and VMAT techniques. These metrics include: 1) the integral dose and the volume receiving intermediate dose levels between IMRT and VMATI plans; 2) the use of 4D CT to determine the internal motion margin; and 3) evaluating the dosimetry of every plan through patient‐specific QA. These factors may impact the overall treatment plan quality and outcomes from the individual planning technique used. In this study, we also examined the significance of using two arcs vs. a single‐arc VMAT technique for PTV coverage, OARs doses, monitor units and delivery time. Thirteen patients, stage T2‐T3 N0‐N1 (TNM AJCC 7th edn.), PTV volume median 395 cc (range 281–601 cc), median age 69 years (range 53 to 85), were treated from July 2010 to June 2011 with a four‐field (n=4) or five‐field (n=9) step‐and‐shoot IMRT technique using a 6 MV beam to a prescribed dose of 50 Gy in 20 to 25 F. These patients were retrospectively replanned using single arc (VMATI, 91 control points) and two arcs (VMATII, 182 control points). All treatment plans of the 13 study cases were evaluated using various dose‐volume metrics. These included PTV D99, PTV D95, PTV V9547.5Gy(95%), PTV mean dose, Dmax, PTV dose conformity (Van't Riet conformation

  11. The Impact of the ACA Medicaid Expansions on Health Insurance Coverage through 2015 and Coverage Disparities by Age, Race/Ethnicity, and Gender.

    PubMed

    Wehby, George L; Lyu, Wei

    2018-04-01

    Examine the ACA Medicaid expansion effects on Medicaid take-up and private coverage through 2015 and coverage disparities by age, race/ethnicity, and gender. 2011-2015 American Community Survey for 3,137,989 low-educated adults aged 19-64 years. Difference-in-differences regressions accounting for national coverage trends and state fixed effects. Expansion effects doubled in 2015 among low-educated adults, with a nearly 8 percentage-point increase in Medicaid take-up and 6 percentage-point decline in uninsured rate. Significant coverage gains were observed across virtually all examined groups by age, gender, and race/ethnicity. Take-up and insurance declines were strongest among younger adults and were generally close by gender and race/ethnicity. Despite the increased take-up however, coverage disparities remained sizeable, especially for young adults and Hispanics who had declining but still high uninsured rates in 2015. There was some evidence of private coverage crowd-out in certain subgroups, particularly among young adults aged 19-26 years and women, including in both individually purchased and employer-sponsored coverage. The ACA Medicaid expansions have continued to increase coverage in 2015 across the entire population of low-educated adults and have reduced age disparities in coverage. However, there is still a need for interventions that target eligible young and Hispanic adults. © Health Research and Educational Trust.

  12. Assessment of population coverage of hypertension screening in Thailand based on the effective coverage framework.

    PubMed

    Charoendee, Kulpimol; Sriratanaban, Jiruth; Aekplakorn, Wichai; Hanvoravongchai, Piya

    2018-03-27

    Hypertension (HT) is a major risk factor, and accessible and effective HT screening services are necessary. The effective coverage framework is an assessment tool that can be used to assess health service performance by considering target population who need and receive quality service. The aim of this study is to measure effective coverage of hypertension screening services at the provincial level in Thailand. Over 40 million individual health service records in 2013 were acquired. Data on blood pressure measurement, risk assessment, HT diagnosis and follow up were analyzed. The effectiveness of the services was assessed based on a set of quality criteria for pre-HT, suspected HT, and confirmed HT cases. Effective coverage of HT services for all non-HT Thai population aged 15 or over was estimated for each province and for all Thailand. Population coverage of HT screening is 54.6%, varying significantly across provinces. Among those screened, 28.9% were considered pre-HT, and another 6.0% were suspected HT cases. The average provincial effective coverage was at 49.9%. Around four-fifths (82.6%) of the pre-HT group received HT and Cardiovascular diseases (CVD) risk assessment. Among the suspected HT cases, less than half (38.0%) got a follow-up blood pressure measurement within 60 days from the screening date. Around 9.2% of the suspected cases were diagnosed as having HT, and only one-third of them (36.5%) received treatment within 6 months. Within this group, 21.8% obtained CVD risk assessment, and half of them had their blood pressure under control (50.8%) with less than 1 % (0.7%) of them managed to get the CVD risk reduced. Our findings suggest that hypertension screening coverage, post-screening service quality, and effective coverage of HT screening in Thailand were still low and they vary greatly across provinces. It is imperative that service coverage and its effectiveness are assessed, and both need improvement. Despite some limitations, measurement of

  13. Multi-Objective Optimization of Spacecraft Trajectories for Small-Body Coverage Missions

    NASA Technical Reports Server (NTRS)

    Hinckley, David, Jr.; Englander, Jacob; Hitt, Darren

    2017-01-01

    Visual coverage of surface elements of a small-body object requires multiple images to be taken that meet many requirements on their viewing angles, illumination angles, times of day, and combinations thereof. Designing trajectories capable of maximizing total possible coverage may not be useful since the image target sequence and the feasibility of said sequence given the rotation-rate limitations of the spacecraft are not taken into account. This work presents a means of optimizing, in a multi-objective manner, surface target sequences that account for such limitations.

  14. Effect of maternal HIV status on vaccination coverage among sub-Saharan African children: A socio-ecological analysis.

    PubMed

    Adetokunboh, Olatunji O; Uthman, Olalekan A; Wiysonge, Charles S

    2018-05-02

    We investigated the relationship between maternal HIV status and uptake of the full series of three doses of diphtheria-tetanus-pertussis containing vaccines (DTP3) in sub-Saharan African children. We used data obtained from demographic and health surveys conducted in sub-Saharan Africa. We conducted meta-analysis and calculated pooled odds ratios (OR) for the association between maternal HIV status and DTP3 vaccination status for each country. A total of 4,187 out of 5,537 children of women living with HIV received DTP3 (75.6%), compared to 71,290 of 113,513 (62.8%) children of HIV negative women. National DTP3 coverage among children of HIV-positive women varied between 24% and 96% while among children of HIV negative women it was between 26% and 92%. Overall pooled result showed no significant difference in DTP3 coverage between the two groups (OR = 1.05; 95% confidence interval 0.91 - 1.22), with statistically significant heterogeneity (Chi 2 = 91.63, P = 0.000, I 2 = 71.6%). There was no significant association between DTP3 coverage and maternal HIV status in sub-Saharan Africa. However, DTP3 coverage for both HIV-exposed and non-exposed children were below the required target. Meta-regression revealed no significant association between DTP3 coverage and country characteristics (e.g. HIV prevalence among women, antiretroviral therapy coverage, gross domestic product per capita, human development index, adult literacy rate and sub-region). Improved prevention of mother-to-child transmission services might have contributed to some extent to the higher DTP3 vaccination coverage among the HIV-exposed children. There is also need to address barriers impeding uptake of vaccination among HIV-exposed and non-exposed children.

  15. Patterns-of-failure guided biological target volume definition for head and neck cancer patients: FDG-PET and dosimetric analysis of dose escalation candidate subregions.

    PubMed

    Mohamed, Abdallah S R; Cardenas, Carlos E; Garden, Adam S; Awan, Musaddiq J; Rock, Crosby D; Westergaard, Sarah A; Brandon Gunn, G; Belal, Abdelaziz M; El-Gowily, Ahmed G; Lai, Stephen Y; Rosenthal, David I; Fuller, Clifton D; Aristophanous, Michalis

    2017-08-01

    To identify the radio-resistant subvolumes in pretreatment FDG-PET by mapping the spatial location of the origin of tumor recurrence after IMRT for head-and-neck squamous cell cancer to the pretreatment FDG-PET/CT. Patients with local/regional recurrence after IMRT with available FDG-PET/CT and post-failure CT were included. For each patient, both pre-therapy PET/CT and recurrence CT were co-registered with the planning CT (pCT). A 4-mm radius was added to the centroid of mapped recurrence growth target volumes (rGTV's) to create recurrence nidus-volumes (NVs). The overlap between boost-tumor-volumes (BTV) representing different SUV thresholds/margins combinations and NVs was measured. Forty-seven patients were eligible. Forty-two (89.4%) had type A central high dose failure. Twenty-six (48%) of type A rGTVs were at the primary site and 28 (52%) were at the nodal site. The mean dose of type A rGTVs was 71Gy. BTV consisting of 50% of the maximum SUV plus 10mm margin was the best subvolume for dose boosting due to high coverage of primary site NVs (92.3%), low average relative volume to CTV1 (41%), and least average percent voxels outside CTV1 (19%). The majority of loco-regional recurrences originate in the regions of central-high-dose. When correlated with pretreatment FDG-PET, the majority of recurrences originated in an area that would be covered by additional 10mm margin on the volume of 50% of the maximum FDG uptake. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Experimental determination of particle range and dose distribution in thick targets through fragmentation reactions of stable heavy ions.

    PubMed

    Inaniwa, Taku; Kohno, Toshiyuki; Tomitani, Takehiro; Urakabe, Eriko; Sato, Shinji; Kanazawa, Mitsutaka; Kanai, Tatsuaki

    2006-09-07

    In radiation therapy with highly energetic heavy ions, the conformal irradiation of a tumour can be achieved by using their advantageous features such as the good dose localization and the high relative biological effectiveness around their mean range. For effective utilization of such properties, it is necessary to evaluate the range of incident ions and the deposited dose distribution in a patient's body. Several methods have been proposed to derive such physical quantities; one of them uses positron emitters generated through projectile fragmentation reactions of incident ions with target nuclei. We have proposed the application of the maximum likelihood estimation (MLE) method to a detected annihilation gamma-ray distribution for determination of the range of incident ions in a target and we have demonstrated the effectiveness of the method with computer simulations. In this paper, a water, a polyethylene and a polymethyl methacrylate target were each irradiated with stable (12)C, (14)N, (16)O and (20)Ne beams. Except for a few combinations of incident beams and targets, the MLE method could determine the range of incident ions R(MLE) with a difference between R(MLE) and the experimental range of less than 2.0 mm under the circumstance that the measurement of annihilation gamma rays was started just after the irradiation of 61.4 s and lasted for 500 s. In the process of evaluating the range of incident ions with the MLE method, we must calculate many physical quantities such as the fluence and the energy of both primary ions and fragments as a function of depth in a target. Consequently, by using them we can obtain the dose distribution. Thus, when the mean range of incident ions is determined with the MLE method, the annihilation gamma-ray distribution and the deposited dose distribution can be derived simultaneously. The derived dose distributions in water for the mono-energetic heavy-ion beams of four species were compared with those measured with an

  17. Spline-based procedures for dose-finding studies with active control

    PubMed Central

    Helms, Hans-Joachim; Benda, Norbert; Zinserling, Jörg; Kneib, Thomas; Friede, Tim

    2015-01-01

    In a dose-finding study with an active control, several doses of a new drug are compared with an established drug (the so-called active control). One goal of such studies is to characterize the dose–response relationship and to find the smallest target dose concentration d*, which leads to the same efficacy as the active control. For this purpose, the intersection point of the mean dose–response function with the expected efficacy of the active control has to be estimated. The focus of this paper is a cubic spline-based method for deriving an estimator of the target dose without assuming a specific dose–response function. Furthermore, the construction of a spline-based bootstrap CI is described. Estimator and CI are compared with other flexible and parametric methods such as linear spline interpolation as well as maximum likelihood regression in simulation studies motivated by a real clinical trial. Also, design considerations for the cubic spline approach with focus on bias minimization are presented. Although the spline-based point estimator can be biased, designs can be chosen to minimize and reasonably limit the maximum absolute bias. Furthermore, the coverage probability of the cubic spline approach is satisfactory, especially for bias minimal designs. © 2014 The Authors. Statistics in Medicine Published by John Wiley & Sons Ltd. PMID:25319931

  18. Measuring Adolescent Human Papillomavirus Vaccine Coverage: A Match of Sexually Transmitted Disease Clinic and Immunization Registry Data.

    PubMed

    Pathela, Preeti; Jamison, Kelly; Papadouka, Vikki; Kabir, Rezaul; Markowitz, Lauri E; Dunne, Eileen F; Schillinger, Julia A

    2016-12-01

    Human papillomavirus (HPV) vaccine is recommended for adolescents. By the end of 2013, 64% of female and 40% of male New York City residents aged 13-18 years had received ≥1 HPV vaccine dose. Adolescents attending sexually transmitted disease (STD) clinics are at high risk for HPV exposure and could benefit from vaccination. Our objective was to estimate HPV vaccination coverage for this population. We matched records of New York City's STD clinic patients aged 13-18 years during 2010-2013 with the Citywide Immunization Registry. We assessed HPV vaccine initiation (≥1 dose) and series completion (≥3 doses among those who initiated) as of clinic visit date and by patient demographics. We compared receipt of ≥1 dose for HPV, tetanus-diphtheria-acellular pertussis, and meningococcal conjugate vaccine. Eighty-two percent of clinic attendees (13,505/16,364) had records in the Citywide Immunization Registry. Receipt of ≥1 HPV dose increased during 2010-2013 (females: 57.6%-69.7%; males: 1.5%-36.3%). Among females, ≥1-dose coverage was lowest among whites (53.4%) and highest among Hispanics (73.3%); among males, ≥1-dose coverage was lowest among whites (6.9%) and highest among Asians (20.9%). Series completion averaged 57.7% (females) and 28.0% (males), with little variation by race/ethnicity or poverty level. Receipt of ≥1 dose was 59.7% for HPV, 82% for tetanus-diphtheria-acellular pertussis, and 76% for meningococcal conjugate vaccines. HPV vaccine initiation and completion were low among adolescent STD clinic patients; coverage was lower compared with other recommended vaccines. STD clinics may be good venues for delivering HPV vaccine, thereby enhancing efforts to improve HPV vaccination. Copyright © 2016 Society for Adolescent Health and Medicine. All rights reserved.

  19. Oral cholera vaccine coverage in hard-to-reach fishermen communities after two mass Campaigns, Malawi, 2016.

    PubMed

    Sauvageot, Delphine; Saussier, Christel; Gobeze, Abebe; Chipeta, Sikhona; Mhango, Innocent; Kawalazira, Gift; Mengel, Martin A; Legros, Dominique; Cavailler, Philippe; M'bang'ombe, Maurice

    2017-09-12

    From December 2015 to August 2016, a large epidemic of cholera affected the fishermen of Lake Chilwa in Malawi. A first reactive Oral Cholera Vaccines (OCV) campaign was organized, in February, in a 2km radius of the lake followed by a preemptive one, conducted in November, in a 25km radius. We present the vaccine coverage reached in hard-to-reach population using simplified delivery strategies. We conducted two-stage random-sampling cross-sectional surveys among individuals living in a 2km and 25km radius of Lake Chilwa (islands and floating homes included). Individuals aged 12months and older from Machinga and Zomba districts were sampled: 43 clusters of 14 households were surveyed. Simplified strategies were used for those living in islands and floating homes: self- delivery and community-supervised delivery of the second dose. Vaccine coverage (VC) for at-least-two-doses was estimated taking into account sampling weights and design effects. A total of 1176 households were surveyed (2.7% of non-response). Among the 2833 individuals living in the 2km radius of Lake and the 2915 in the 25km radius: 457 (16.1%) and 239 (8.2%) lived in floating homes or on islands at some point in the year, respectively. For the overall population, VC was 75.6% and 54.2%, respectively. In the 2km radius, VC was 92.2% for those living on the lake at some point of the year: 271 (64.8%) used the simplified strategies. The main reasons for non-vaccination were absence during the campaign and vaccine shortage. Few adverse events occurring in the 24h following vaccination was reported. We reached a high two-dose coverage of the most at-risk population using simplified delivery strategies. Because of the high fishermen mobility, regular catch-up campaigns or another strategy specifically targeting fishermen need to be assessed for more efficient vaccines use. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Challenges of coverage policy development for next-generation tumor sequencing panels: experts and payers weigh in.

    PubMed

    Trosman, Julia R; Weldon, Christine B; Kelley, R Kate; Phillips, Kathryn A

    2015-03-01

    Next-generation tumor sequencing (NGTS) panels, which include multiple established and novel targets across cancers, are emerging in oncology practice, but lack formal positive coverage by US payers. Lack of coverage may impact access and adoption. This study identified challenges of NGTS coverage by private payers. We conducted semi-structured interviews with 14 NGTS experts on potential NGTS benefits, and with 10 major payers, representing more than 125,000,000 enrollees, on NGTS coverage considerations. We used the framework approach of qualitative research for study design and thematic analyses and simple frequencies to further describe findings. All interviewed payers see potential NGTS benefits, but all noted challenges to formal coverage: 80% state that inherent features of NGTS do not fit the medical necessity definition required for coverage, 70% view NGTS as a bundle of targets versus comprehensive tumor characterization and may evaluate each target individually, and 70% express skepticism regarding new evidence methods proposed for NGTS. Fifty percent of payers expressed sufficient concerns about NGTS adoption and implementation that will preclude their ability to issue positive coverage policies. Payers perceive that NGTS holds significant promise but, in its current form, poses disruptive challenges to coverage policy frameworks. Proactive multidisciplinary efforts to define the direction for NGTS development, evidence generation, and incorporation into coverage policy are necessary to realize its promise and provide patient access. This study contributes to current literature, as possibly the first study to directly interview US payers on NGTS coverage and reimbursement. Copyright © 2015 by the National Comprehensive Cancer Network.

  1. Challenges of Coverage Policy Development for Next-Generation Tumor Sequencing Panels: Experts and Payers Weigh In

    PubMed Central

    Trosman, Julia R.; Weldon, Christine B.; Kate Kelley, R.; Phillips, Kathryn A.

    2015-01-01

    Background Next-generation tumor sequencing (NGTS) panels, which include multiple established and novel targets across cancers, are emerging in oncology practice, but lack formal positive coverage by US payers. Lack of coverage may impact access and adoption. This study identified challenges of NGTS coverage by private payers. Methods We conducted semi-structured interviews with 14 NGTS experts on potential NGTS benefits, and with 10 major payers, representing more than 125,000,000 enrollees, on NGTS coverage considerations. We used the framework approach of qualitative research for study design and thematic analyses and simple frequencies to further describe findings. Results All interviewed payers see potential NGTS benefits, but all noted challenges to formal coverage: 80% state that inherent features of NGTS do not fit the medical necessity definition required for coverage, 70% view NGTS as a bundle of targets versus comprehensive tumor characterization and may evaluate each target individually, and 70% express skepticism regarding new evidence methods proposed for NGTS. Fifty percent of payers expressed sufficient concerns about NGTS adoption and implementation that will preclude their ability to issue positive coverage policies. Conclusions Payers perceive that NGTS holds significant promise but, in its current form, poses disruptive challenges to coverage policy frameworks. Proactive multidisciplinary efforts to define the direction for NGTS development, evidence generation, and incorporation into coverage policy are necessary to realize its promise and provide patient access. This study contributes to current literature, as possibly the first study to directly interview US payers on NGTS coverage and reimbursement. PMID:25736008

  2. Coverage-guaranteed sensor node deployment strategies for wireless sensor networks.

    PubMed

    Fan, Gaojuan; Wang, Ruchuan; Huang, Haiping; Sun, Lijuan; Sha, Chao

    2010-01-01

    Deployment quality and cost are two conflicting aspects in wireless sensor networks. Random deployment, where the monitored field is covered by randomly and uniformly deployed sensor nodes, is an appropriate approach for large-scale network applications. However, their successful applications depend considerably on the deployment quality that uses the minimum number of sensors to achieve a desired coverage. Currently, the number of sensors required to meet the desired coverage is based on asymptotic analysis, which cannot meet deployment quality due to coverage overestimation in real applications. In this paper, we first investigate the coverage overestimation and address the challenge of designing coverage-guaranteed deployment strategies. To overcome this problem, we propose two deployment strategies, namely, the Expected-area Coverage Deployment (ECD) and BOundary Assistant Deployment (BOAD). The deployment quality of the two strategies is analyzed mathematically. Under the analysis, a lower bound on the number of deployed sensor nodes is given to satisfy the desired deployment quality. We justify the correctness of our analysis through rigorous proof, and validate the effectiveness of the two strategies through extensive simulation experiments. The simulation results show that both strategies alleviate the coverage overestimation significantly. In addition, we also evaluate two proposed strategies in the context of target detection application. The comparison results demonstrate that if the target appears at the boundary of monitored region in a given random deployment, the average intrusion distance of BOAD is considerably shorter than that of ECD with the same desired deployment quality. In contrast, ECD has better performance in terms of the average intrusion distance when the invasion of intruder is from the inside of monitored region.

  3. Study for reducing lung dose of upper thoracic esophageal cancer radiotherapy by auto-planning: volumetric-modulated arc therapy vs intensity-modulated radiation therapy.

    PubMed

    Chen, Hua; Wang, Hao; Gu, Hengle; Shao, Yan; Cai, Xuwei; Fu, Xiaolong; Xu, Zhiyong

    2017-10-27

    This study aimed to investigate the dosimetric differences and lung sparing between volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) in the treatment of upper thoracic esophageal cancer with T3N0M0 for preoperative radiotherapy by auto-planning (AP). Sixteen patient cases diagnosed with upper thoracic esophageal cancer T3N0M0 for preoperative radiotherapy were retrospectively studied, and 3 plans were generated for each patient: full arc VMAT AP plan with double arcs, partial arc VMAT AP plan with 6 partial arcs, and conventional IMRT AP plan. A simultaneous integrated boost with 2 levels was planned in all patients. Target coverage, organ at risk sparing, treatment parameters including monitor units and treatment time (TT) were evaluated. Wilcoxon signed-rank test was used to check for significant differences (p < 0.05) between datasets. VMAT plans (pVMAT and fVMAT) significantly reduced total lung volume treated above 20 Gy (V 20 ), 25 Gy (V 25 ), 30 Gy (V 30 ), 35 Gy (V 35 ), 40 Gy (V 40 ), and without increasing the value of V 10 , V 13 , and V 15 . For V 5 of total lung value, pVMAT was similar to aIMRT, and it was better than fVMAT. Both pVMAT and fVMAT improved the target dose coverage and significantly decreased maximum dose for the spinal cord, monitor unit, and TT. No significant difference was observed with respect to V 10 and V 15 of body. VMAT AP plan was a good option for treating upper thoracic esophageal cancer with T3N0M0, especially partial arc VMAT AP plan. It had the potential to effectively reduce lung dose in a shorter TT and with superior target coverage and dose homogeneity. Copyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  4. SU-E-T-453: Optimization of Dose Gradient for Gamma Knife Radiosurgery.

    PubMed

    Sheth, N; Chen, Y; Yang, J

    2012-06-01

    The goals of stereotactic radiosurgery (SRS) are the ablation of target tissue and sparing of critical normal tissue. We develop tools to aid in the selection of collimation and prescription (Rx) isodose line to optimize the dose gradient for single isocenter intracranial stereotactic radiosurgery (SRS) with GammaKnife 4C utilizing the updated physics data in GammaPlan v10.1. Single isocenter intracranial SRS plans were created to treat the center of a solid water anthropomorphism head phantom for each GammaKnife collimator (4 mm, 8 mm, 14 mm, and 18 mm). The dose gradient, defined as the difference of effective radii of spheres equal to half and full Rx volumes, and Rx treatment volume was analyzed for isodoses from 99% to 20% of Rx. The dosimetric data on Rx volume and dose gradient vs. Rx isodose for each collimator was compiled into an easy to read nomogram as well as plotted graphically. The 4, 8, 14, and 18 mm collimators have the sharpest dose gradient at the 64%, 70%, 76%, and 77% Rx isodose lines, respectively. This corresponds to treating 4.77 mm, 8.86 mm, 14.78 mm, and 18.77 mm diameter targets with dose gradients radii of 1.06 mm, 1.63 mm, 2.54 mm, and 3.17 mm, respectively. We analyzed the dosimetric data for the most recent version of GammaPlan treatment planning software to develop tools that when applied clinically will aid in the selection of a collimator and Rx isodose line for optimal dose gradient and target coverage for single isocenter intracranial SRS with GammaKnife 4C. © 2012 American Association of Physicists in Medicine.

  5. Delaunay Triangulation as a New Coverage Measurement Method in Wireless Sensor Network

    PubMed Central

    Chizari, Hassan; Hosseini, Majid; Poston, Timothy; Razak, Shukor Abd; Abdullah, Abdul Hanan

    2011-01-01

    Sensing and communication coverage are among the most important trade-offs in Wireless Sensor Network (WSN) design. A minimum bound of sensing coverage is vital in scheduling, target tracking and redeployment phases, as well as providing communication coverage. Some methods measure the coverage as a percentage value, but detailed information has been missing. Two scenarios with equal coverage percentage may not have the same Quality of Coverage (QoC). In this paper, we propose a new coverage measurement method using Delaunay Triangulation (DT). This can provide the value for all coverage measurement tools. Moreover, it categorizes sensors as ‘fat’, ‘healthy’ or ‘thin’ to show the dense, optimal and scattered areas. It can also yield the largest empty area of sensors in the field. Simulation results show that the proposed DT method can achieve accurate coverage information, and provides many tools to compare QoC between different scenarios. PMID:22163792

  6. Stereotactic, Single-Dose Irradiation of Lung Tumors: A Comparison of Absolute Dose and Dose Distribution Between Pencil Beam and Monte Carlo Algorithms Based on Actual Patient CT Scans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen Huixiao; Lohr, Frank; Fritz, Peter

    2010-11-01

    Purpose: Dose calculation based on pencil beam (PB) algorithms has its shortcomings predicting dose in tissue heterogeneities. The aim of this study was to compare dose distributions of clinically applied non-intensity-modulated radiotherapy 15-MV plans for stereotactic body radiotherapy between voxel Monte Carlo (XVMC) calculation and PB calculation for lung lesions. Methods and Materials: To validate XVMC, one treatment plan was verified in an inhomogeneous thorax phantom with EDR2 film (Eastman Kodak, Rochester, NY). Both measured and calculated (PB and XVMC) dose distributions were compared regarding profiles and isodoses. Then, 35 lung plans originally created for clinical treatment by PB calculationmore » with the Eclipse planning system (Varian Medical Systems, Palo Alto, CA) were recalculated by XVMC (investigational implementation in PrecisePLAN [Elekta AB, Stockholm, Sweden]). Clinically relevant dose-volume parameters for target and lung tissue were compared and analyzed statistically. Results: The XVMC calculation agreed well with film measurements (<1% difference in lateral profile), whereas the deviation between PB calculation and film measurements was up to +15%. On analysis of 35 clinical cases, the mean dose, minimal dose and coverage dose value for 95% volume of gross tumor volume were 1.14 {+-} 1.72 Gy, 1.68 {+-} 1.47 Gy, and 1.24 {+-} 1.04 Gy lower by XVMC compared with PB, respectively (prescription dose, 30 Gy). The volume covered by the 9 Gy isodose of lung was 2.73% {+-} 3.12% higher when calculated by XVMC compared with PB. The largest differences were observed for small lesions circumferentially encompassed by lung tissue. Conclusions: Pencil beam dose calculation overestimates dose to the tumor and underestimates lung volumes exposed to a given dose consistently for 15-MV photons. The degree of difference between XVMC and PB is tumor size and location dependent. Therefore XVMC calculation is helpful to further optimize treatment

  7. Four-Dimensional Patient Dose Reconstruction for Scanned Ion Beam Therapy of Moving Liver Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richter, Daniel; TU Darmstadt, Darmstadt; Saito, Nami

    2014-05-01

    Purpose: Estimation of the actual delivered 4-dimensional (4D) dose in treatments of patients with mobile hepatocellular cancer with scanned carbon ion beam therapy. Methods and Materials: Six patients were treated with 4 fractions to a total relative biological effectiveness (RBE)–weighted dose of 40 Gy (RBE) using a single field. Respiratory motion was addressed by dedicated margins and abdominal compression (5 patients) or gating (1 patient). 4D treatment dose reconstructions based on the treatment records and the measured motion monitoring data were performed for the single-fraction dose and a total of 17 fractions. To assess the impact of uncertainties in the temporalmore » correlation between motion trajectory and beam delivery sequence, 3 dose distributions for varying temporal correlation were calculated per fraction. For 3 patients, the total treatment dose was formed from the fractional distributions using all possible combinations. Clinical target volume (CTV) coverage was analyzed using the volumes receiving at least 95% (V{sub 95}) and 107% (V{sub 107}) of the planned doses. Results: 4D dose reconstruction based on daily measured data is possible in a clinical setting. V{sub 95} and V{sub 107} values for the single fractions ranged between 72% and 100%, and 0% and 32%, respectively. The estimated total treatment dose to the CTV exhibited improved and more robust dose coverage (mean V{sub 95} > 87%, SD < 3%) and overdose (mean V{sub 107} < 4%, SD < 3%) with respect to the single-fraction dose for all analyzed patients. Conclusions: A considerable impact of interplay effects on the single-fraction CTV dose was found for most of the analyzed patients. However, due to the fractionated treatment, dose heterogeneities were substantially reduced for the total treatment dose. 4D treatment dose reconstruction for scanned ion beam therapy is technically feasible and may evolve into a valuable tool for dose assessment.« less

  8. Comparison of pencil beam–based homogeneous vs inhomogeneous target dose planning for stereotactic body radiotherapy of peripheral lung tumors through Monte Carlo–based recalculation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ohtakara, Kazuhiro, E-mail: ohtakara@murakami.asahi-u.ac.jp; Hoshi, Hiroaki

    2015-10-01

    This study was conducted to ascertain whether homogeneous target dose planning is suitable for stereotactic body radiotherapy (SBRT) of peripheral lung cancer under appropriate breath-holding. For 20 peripheral lung tumors, paired dynamic conformal arc plans were generated by only adjusting the leaf margin to the planning target volume (PTV) edge for fulfilling the conditions such that the prescription isodose surface (IDS) encompassing exactly 95% of the PTV (PTV D{sub 95}) corresponds to 95% and 80% IDS, normalized to 100% at the PTV isocenter under a pencil beam (PB) algorithm with radiologic path length correction. These plans were recalculated using themore » x-ray voxel Monte Carlo (XVMC) algorithm under otherwise identical conditions, and then compared. Lesions abutting the parietal pleura or not were defined as edge or island tumors, respectively, and the influences of the target volume and its location relative to the chest wall on the target dose were examined. The median (range) leaf margin required for the 95% and 80% plans was 3.9 mm (1.3 to 5.0) and −1.2 mm (−1.8 to 0.1), respectively. Notably, the latter was significantly correlated negatively with PTV. In the 80% plans, the PTV D{sub 95} was slightly higher under XVMC, whereas the PTV D{sub 98} was significantly lower, irrespective of the dose calculation algorithm used. Other PTV and all gross tumor volume doses were significantly higher, while the lung doses outside the PTV were slightly lower. The target doses increased as a function of PTV and were significantly lower for island tumors than for edge tumors. In conclusion, inhomogeneous target dose planning using smaller leaf margin for a larger tumor volume was deemed suitable in ensuring more sufficient target dose while slightly reducing lung dose. In addition, more inhomogeneous target dose planning using <80% IDS (e.g., 70%) for PTV covering would be preferable for island tumors.« less

  9. Human papillomavirus (HPV) vaccination coverage in young Australian women is higher than previously estimated: independent estimates from a nationally representative mobile phone survey.

    PubMed

    Brotherton, Julia M L; Liu, Bette; Donovan, Basil; Kaldor, John M; Saville, Marion

    2014-01-23

    Accurate estimates of coverage are essential for estimating the population effectiveness of human papillomavirus (HPV) vaccination. Australia has a purpose built National HPV Vaccination Program Register for monitoring coverage, however notification of doses administered to young women in the community during the national catch-up program (2007-2009) was not compulsory. In 2011, we undertook a population-based mobile phone survey of young women to independently estimate HPV vaccination coverage. Randomly generated mobile phone numbers were dialed to recruit women aged 22-30 (age eligible for HPV vaccination) to complete a computer assisted telephone interview. Consent was sought to validate self reported HPV vaccination status against the national register. Coverage rates were calculated based on self report and weighted to the age and state of residence structure of the Australian female population. These were compared with coverage estimates from the register using Australian Bureau of Statistics estimated resident populations as the denominator. Among the 1379 participants, the national estimate for self reported HPV vaccination coverage for doses 1/2/3, respectively, weighted for age and state of residence, was 64/59/53%. This compares with coverage of 55/45/32% and 49/40/28% based on register records, using 2007 and 2011 population data as the denominators respectively. Some significant differences in coverage between the states were identified. 20% (223) of women returned a consent form allowing validation of doses against the register and provider records: among these women 85.6% (538) of self reported doses were confirmed. We confirmed that coverage rates for young women vaccinated in the community (at age 18-26 years) are underestimated by the national register and that under-notification is greater for second and third doses. Using 2011 population estimates, rather than estimates contemporaneous with the program rollout, reduces register-based coverage

  10. Decreasing Temporal Lobe Dose With Five-Field Intensity-Modulated Radiotherapy for Treatment of Pituitary Macroadenomas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parhar, Preeti K.; Duckworth, Tamara; Shah, Parinda

    2010-10-01

    Purpose: To compare temporal lobe dose delivered by three pituitary macroadenoma irradiation techniques: three-field three-dimensional conformal radiotherapy (3D-CRT), three-field intensity-modulated radiotherapy (3F IMRT), and a proposed novel alternative of five-field IMRT (5F IMRT). Methods and Materials: Computed tomography-based external beam radiotherapy planning was performed for 15 pituitary macroadenoma patients treated at New York University between 2002 and 2007 using: 3D-CRT (two lateral, one midline superior anterior oblique [SAO] beams), 3F IMRT (same beam angles), and 5F IMRT (same beam angles with additional right SAO and left SAO beams). Prescription dose was 45 Gy. Target volumes were: gross tumor volume (GTV)more » = macroadenoma, clinical target volume (CTV) = GTV, and planning target volume = CTV + 0.5 cm. Structure contouring was performed by two radiation oncologists guided by an expert neuroradiologist. Results: Five-field IMRT yielded significantly decreased temporal lobe dose delivery compared with 3D-CRT and 3F IMRT. Temporal lobe sparing with 5F IMRT was most pronounced at intermediate doses: mean V25Gy (% of total temporal lobe volume receiving {>=}25 Gy) of 13% vs. 28% vs. 29% for right temporal lobe and 14% vs. 29% vs. 30% for left temporal lobe for 5F IMRT, 3D-CRT, and 3F IMRT, respectively (p < 10{sup -7} for 5F IMRT vs. 3D-CRT and 5F IMRT vs. 3F IMRT). Five-field IMRT plans did not compromise target coverage, exceed normal tissue dose constraints, or increase estimated brain integral dose. Conclusions: Five-field IMRT irradiation technique results in a statistically significant decrease in the dose to the temporal lobes and may thus help prevent neurocognitive sequelae in irradiated pituitary macroadenoma patients.« less

  11. Implications of improved diagnostic imaging of small nodal metastases in head and neck cancer: Radiotherapy target volume transformation and dose de-escalation.

    PubMed

    van den Bosch, Sven; Vogel, Wouter V; Raaijmakers, Cornelis P; Dijkema, Tim; Terhaard, Chris H J; Al-Mamgani, Abrahim; Kaanders, Johannes H A M

    2018-05-03

    Diagnostic imaging continues to evolve, and now has unprecedented accuracy for detecting small nodal metastasis. This influences the tumor load in elective target volumes and subsequently has consequences for the radiotherapy dose required to control disease in these volumes. Small metastases that used to remain subclinical and were included in elective volumes, will nowadays be detected and included in high-dose volumes. Consequentially, high-dose volumes will more often contain low-volume disease. These target volume transformations lead to changes in the tumor burden in elective and "gross" tumor volumes with implications for the radiotherapy dose prescribed to these volumes. For head and neck tumors, nodal staging has evolved from mere palpation to combinations of high-resolution imaging modalities. A traditional nodal gross tumor volume in the neck typically had a minimum diameter of 10-15 mm, while nowadays much smaller tumor deposits are detected in lymph nodes. However, the current dose levels for elective nodal irradiation were empirically determined in the 1950s, and have not changed since. In this report the radiobiological consequences of target volume transformation caused by modern imaging of the neck are evaluated, and theoretically derived reductions of dose in radiotherapy for head and neck cancer are proposed. The concept of target volume transformation and subsequent strategies for dose adaptation applies to many other tumor types as well. Awareness of this concept may result in new strategies for target definition and selection of dose levels with the aim to provide optimal tumor control with less toxicity. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  12. Can coverage of schistosomiasis and soil transmitted helminthiasis control programmes targeting school-aged children be improved? New approaches.

    PubMed

    Massa, K; Olsen, A; Sheshe, A; Ntakamulenga, R; Ndawi, B; Magnussen, P

    2009-11-01

    Control programmes generally use a school-based strategy of mass drug administration to reduce morbidity of schistosomiasis and soil-transmitted helminthiasis (STH) in school-aged populations. The success of school-based programmes depends on treatment coverage. The community-directed treatment (ComDT) approach has been implemented in the control of onchocerciasis and lymphatic filariasis in Africa and improves treatment coverage. This study compared the treatment coverage between the ComDT approach and the school-based treatment approach, where non-enrolled school-aged children were invited for treatment, in the control of schistosomiasis and STH among enrolled and non-enrolled school-aged children. Coverage during the first treatment round among enrolled children was similar for the two approaches (ComDT: 80.3% versus school: 82.1%, P=0.072). However, for the non-enrolled children the ComDT approach achieved a significantly higher coverage than the school-based approach (80.0 versus 59.2%, P<0.001). Similar treatment coverage levels were attained at the second treatment round. Again, equal levels of treatment coverage were found between the two approaches for the enrolled school-aged children, while the ComDT approach achieved a significantly higher coverage in the non-enrolled children. The results of this study showed that the ComDT approach can obtain significantly higher treatment coverage among the non-enrolled school-aged children compared to the school-based treatment approach for the control of schistosomiasis and STH.

  13. Dose enhancement effects of gold nanoparticles specifically targeting RNA in breast cancer cells

    PubMed Central

    Metzler, Philipp; Pilarczyk, Götz; Bobu, Vladimir; Kriz, Wilhelm; Hosser, Hiltraud; Fleckenstein, Jens; Krufczik, Matthias; Bestvater, Felix; Wenz, Frederik; Hausmann, Michael

    2018-01-01

    Localization microscopy has shown to be capable of systematic investigations on the arrangement and counting of cellular uptake of gold nanoparticles (GNP) with nanometer resolution. In this article, we show that the application of specially modified RNA targeting gold nanoparticles (“SmartFlares”) can result in ring like shaped GNP arrangements around the cell nucleus. Transmission electron microscopy revealed GNP accumulation in vicinity to the intracellular membrane structures including them of the endoplasmatic reticulum. A quantification of the radio therapeutic dose enhancement as a proof of principle was conducted with γH2AX foci analysis: The application of both—SmartFlares and unmodified GNPs—lead to a significant dose enhancement with a factor of up to 1.2 times the dose deposition compared to non-treated breast cancer cells. This enhancement effect was even more pronounced for SmartFlares. Furthermore, it was shown that a magnetic field of 1 Tesla simultaneously applied during irradiation has no detectable influence on neither the structure nor the dose enhancement dealt by gold nanoparticles. PMID:29346397

  14. Dose Volume Histogram (DVH) Analysis in Intensity Modulation Radiation Therapy (IMRT) Treatments for Prostate Cancers

    NASA Astrophysics Data System (ADS)

    Pyakuryal, Anil

    2009-05-01

    Studies have shown that as many as 8 out of 10 men had prostate cancer by age 80.Prostate cancer begins with small changes (prostatic intraepithelial neoplasia(PIN)) in size and shape of prostate gland cells,known as prostate adenocarcinoma.With advent in technology, prostate cancer has been the most widely used application of IMRT with the longest follow-up periods.Prostate cancer fits the ideal target criteria for IMRT of adjacent sensitive dose-limiting tissue (rectal, bladder).A retrospective study was performed on 10 prostate cancer patients treated with radiation to a limited pelvic field with a standard 4 field arrangements at dose 45 Gy, and an IMRT boost field to a total isocenter dose of 75 Gy.Plans were simulated for 4 field and the supplementary IMRT treatments with proposed dose delivery at 1.5 Gy/fraction in BID basis.An automated DVH analysis software, HART (S. Jang et al., 2008,Med Phys 35,p.2812)was used to perform DVH assessments in IMRT plans.A statistical analysis of dose coverage at targets in prostate gland and neighboring critical organs,and the plan indices(homogeneity, conformality etc) evaluations were also performed using HART extracted DVH statistics.Analyzed results showed a better correlation with the proposed outcomes (TCP, NTCP) of the treatments.

  15. SU-E-T-280: Reconstructed Rectal Wall Dose Map-Based Verification of Rectal Dose Sparing Effect According to Rectum Definition Methods and Dose Perturbation by Air Cavity in Endo-Rectal Balloon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, J; Research Institute of Biomedical Engineering, The Catholic University of Korea, Seoul; Park, H

    Purpose: Dosimetric effect and discrepancy according to the rectum definition methods and dose perturbation by air cavity in an endo-rectal balloon (ERB) were verified using rectal-wall (Rwall) dose maps considering systematic errors in dose optimization and calculation accuracy in intensity-modulated radiation treatment (IMRT) for prostate cancer patients. Methods: When the inflated ERB having average diameter of 4.5 cm and air volume of 100 cc is used for patient, Rwall doses were predicted by pencil-beam convolution (PBC), anisotropic analytic algorithm (AAA), and AcurosXB (AXB) with material assignment function. The errors of dose optimization and calculation by separating air cavity from themore » whole rectum (Rwhole) were verified with measured rectal doses. The Rwall doses affected by the dose perturbation of air cavity were evaluated using a featured rectal phantom allowing insert of rolled-up gafchromic films and glass rod detectors placed along the rectum perimeter. Inner and outer Rwall doses were verified with reconstructed predicted rectal wall dose maps. Dose errors and extent at dose levels were evaluated with estimated rectal toxicity. Results: While AXB showed insignificant difference of target dose coverage, Rwall doses underestimated by up to 20% in dose optimization for the Rwhole than Rwall at all dose range except for the maximum dose. As dose optimization for Rwall was applied, the Rwall doses presented dose error less than 3% between dose calculation algorithm except for overestimation of maximum rectal dose up to 5% in PBC. Dose optimization for Rwhole caused dose difference of Rwall especially at intermediate doses. Conclusion: Dose optimization for Rwall could be suggested for more accurate prediction of rectal wall dose prediction and dose perturbation effect by air cavity in IMRT for prostate cancer. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research Foundation of

  16. Whole Brain Irradiation With Hippocampal Sparing and Dose Escalation on Multiple Brain Metastases: A Planning Study on Treatment Concepts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prokic, Vesna, E-mail: vesna.prokic@uniklinik-freiburg.de; Wiedenmann, Nicole; Fels, Franziska

    2013-01-01

    Purpose: To develop a new treatment planning strategy in patients with multiple brain metastases. The goal was to perform whole brain irradiation (WBI) with hippocampal sparing and dose escalation on multiple brain metastases. Two treatment concepts were investigated: simultaneously integrated boost (SIB) and WBI followed by stereotactic fractionated radiation therapy sequential concept (SC). Methods and Materials: Treatment plans for both concepts were calculated for 10 patients with 2-8 brain metastases using volumetric modulated arc therapy. In the SIB concept, the prescribed dose was 30 Gy in 12 fractions to the whole brain and 51 Gy in 12 fractions to individualmore » brain metastases. In the SC concept, the prescription was 30 Gy in 12 fractions to the whole brain followed by 18 Gy in 2 fractions to brain metastases. All plans were optimized for dose coverage of whole brain and lesions, simultaneously minimizing dose to the hippocampus. The treatment plans were evaluated on target coverage, homogeneity, and minimal dose to the hippocampus and organs at risk. Results: The SIB concept enabled more successful sparing of the hippocampus; the mean dose to the hippocampus was 7.55 {+-} 0.62 Gy and 6.29 {+-} 0.62 Gy, respectively, when 5-mm and 10-mm avoidance regions around the hippocampus were used, normalized to 2-Gy fractions. In the SC concept, the mean dose to hippocampus was 9.8 {+-} 1.75 Gy. The mean dose to the whole brain (excluding metastases) was 33.2 {+-} 0.7 Gy and 32.7 {+-} 0.96 Gy, respectively, in the SIB concept, for 5-mm and 10-mm hippocampus avoidance regions, and 37.23 {+-} 1.42 Gy in SC. Conclusions: Both concepts, SIB and SC, were able to achieve adequate whole brain coverage and radiosurgery-equivalent dose distributions to individual brain metastases. The SIB technique achieved better sparing of the hippocampus, especially when a10-mm hippocampal avoidance region was used.« less

  17. 77 FR 31814 - National Flood Insurance Program (NFIP); Insurance Coverage and Rates

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-30

    ... structures (target repetitive loss buildings) insured under the NFIP. The Notice of Proposed Rulemaking (NPRM) defined target repetitive loss buildings as those with four or more losses, or with two or more flood... flood insurance coverage to a target repetitive loss building, if an owner declined an offer of...

  18. SU-F-BRB-13: Correlation of Improved Target and Organ-At-Risk Dosimetric Quantities and Clinical Outcomes for Helical Tomotherapy Treated Mesothelioma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qi, S; Kishan, A; Alexander, S

    2015-06-15

    Purpose: We have observed improved local control probability (LCP) for adjuvant mesothelioma radiotherapy following pleurectomy/decortication using Tomotherapy compared to the conventional 3D technique (p<0.05). This work assesses the correlation between the improved clinical outcomes against dosimetry quantities. Methods: Thirty-eight mesothelioma cases consecutively treated at our clinic were retrospectively analyzed. Sixteen patients were treated using 3D technique planned on the Eclipse for c-arm accelerators prior to 7/2012; the other 22 cases were treated on Tomotherapy using helical IMRT after 7/2012. Typical 3D plans consisting of 15 MV AP/PA photon fields prescribed to 10 cm depth followed by matching electron fields withmore » energy ranging from 8–16 MeV. Tomotherapy plans were designed using 2.5cm jaw, 0.287 pitch with directional blocking of the contralateral lung. The same prescription of 45 Gy (1.8GyX25) was used for both techniques. The dosimetry metrics for the critical structures: ipsilateral-/contralateral-lung, heart, cord, esophagus, etc were compared between two techniques. Results: Superior LCP is closely associated with improved target coverage. Tomotherapy plans yielded dramatically better target coverage and less dose heterogeneity despite of more advanced/larger disease. The averaged PTV volumes were 2287.3±569.9 (Tomotherapy) vs. 1904.8±312.3cc (3D); V100s were: 91.1±4.0 (%) vs. 47.8±12.7 (%) with heterogeneity indices of 1.20±0.1 vs.1.37±0.38 and for the Tomotherapy and 3D plans, respectively. Compared to the 3D technique, we observed significant lower maximum cord doses (p<0.001), lower mean esophagus doses (p<0.002), and lower heart mean doses when tumor was left-sided (p=0.002). For ipsilateral-/contralateral-lungs, however, the mean doses and V20, V5 of Tomotherapy plans were significantly higher than the 3D plans (p<0.01) regardless which sides of lung were treated. However, rates of radiation pneumonitis were no

  19. Why are IPTp coverage targets so elusive in sub-Saharan Africa? A systematic review of health system barriers.

    PubMed

    Thiam, Sylla; Kimotho, Victoria; Gatonga, Patrick

    2013-10-03

    Use of intermittent preventive treatment (IPTp) is a proven cost-effective intervention for preventing malaria in pregnancy. However, despite the roll-out of IPTp policies across Africa more than ten years ago, utilization levels remain low. This review sought to consolidate scattered evidence as to the health system barriers for IPTp coverage in the continent. Relevant literature from Africa was systematically searched, reviewed and synthesized. Only studies containing primary data were considered. Studies reveal that: (i) poor leadership and governance contribute to slow decentralization of programme management, lack of harmonized guidelines, poor accountability mechanisms, such as robust monitoring and evaluation systems; (ii) low budgetary allocation towards policy implementation slows scale-up, while out-of-pocket expenditure deters women from seeking antenatal services that include IPTp; (iii) there are rampant human resource challenges including low staff motivation levels attributed to such factors as incorrect knowledge of IPTp recommendations and inadequate staffing; (iv) implementation of IPTp policies is hampered by prevailing service delivery barriers, such as long waiting time, long distances to health facilities and poor service provider/client relations; and (v) drug stock-outs and poor management of information and supply chains impair sustained availability of drugs for IPTp. For successful IPTp policy implementation, it is imperative that malaria control programmes target health system barriers that result in low coverage and hence programme ineffectiveness.

  20. Complete immunization coverage and its determinants among children in Malaysia: findings from the National Health and Morbidity Survey (NHMS) 2016.

    PubMed

    Lim, K K; Chan, Y Y; Noor Ani, A; Rohani, J; Siti Norfadhilah, Z A; Santhi, M R

    2017-12-01

    The success of the Expanded Program on Immunization among children will greatly reduce the burden of illness and disability from vaccine preventable diseases. The aim of the study was to evaluate the complete immunization coverage and its determinants among children aged 12-23 months in Malaysia. Cross-sectional study. Data on immunization were extracted from the 2016 National Health and Morbidity Survey. Complete immunization coverage was classified as received all recommended primary vaccine doses by the age of 12 months and verified by vaccination cards, and incompletely immunized if they received partially recommended vaccine dose or not received any recommended vaccine dose or had no vaccination card. The multiple logistic regression analyses were conducted to determine the sociodemographic factors associated with complete immunization coverage. The overall complete immunization coverage among children (verified by cards) was 86.4% (n = 8920, 95% confidence interval: 85.4-87.4). Multivariable logistic regression analyses model revealed that factors significantly associated with complete immunization coverage were ethnicity, occupation of the mother, head of household's education level, and head of household's occupation. While sex, citizenship, household income, mother's age, and marital status were not significantly associated with complete immunization coverage. According to the World Health Organization criteria, the present study demonstrated that the immunization coverage of 86.4% is still unsatisfactory. Thus, the current intervention program should be enhanced in order to achieve the 95% coverage for all antigens in the national vaccination program. Copyright © 2017 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  1. Does ITV vaginal procedure ensure dosimetric coverage during IMRT of post-operative gynaecological tumours without instructions concerning rectal filling?

    PubMed

    Verges, Ramona; Giraldo, Alexandra; Seoane, Alejandro; Toral, Elisabet; Ruiz, M Carmen; Pons, Ariadna; Giralt, Jordi

    2018-01-01

    To find out whether the internal target volume (ITV) vaginal procedure ensures dosimetric coverage during intensity-modulated radiation therapy (IMRT) of post-operative gynaecological tumours without instructions on rectal filling. The ITV vaginal procedure does not necessarily include all movements of the bladder, and does not include changes in the rectal volume. We should know if the vaginal ITV is a useful tool in maintaining CTV coverage during treatment. A retrospective analysis of 24 patients treated between July 2012 and July 2014 with adjuvant IMRT for gynaecological cancer. All patients underwent empty and full bladder CT on simulation (CT-planning) and three weeks later (CT-control). ITV displacement was measured and the 3D vector was calculated. ITV coverage was then evaluated by comparing the volume covered by the prescription isodose on both CT's. Patients were asked to have full bladder but they did not follow recommendations for the rectum. The mean 3D vector was 0.64 ± 0.32 cm (0.09-1.30). The mean ITV coverage loss was 5.8 ± 5.7% (0-20.2). We found a significant positive correlation between the 3D vector and the loss of coverage (Pearson correlation, r  = 0.493, 95% CI: 0.111-0.748, p  = 0.0144). We did not find any significant correlation between the bladder and rectal parameters with the 3D vector and loss of dosimetric coverage. We found a trend between the maximum rectal diameter in CT-planning and 3D vector ( r  = 0.400, 95% CI: -0.004 to 0.692, p  = 0.0529). ITV vaginal procedure contributed to ensuring a good dose coverage without instructions on rectal filling.

  2. Newspaper coverage of mental illness in England 2008-2011.

    PubMed

    Thornicroft, Amalia; Goulden, Robert; Shefer, Guy; Rhydderch, Danielle; Rose, Diana; Williams, Paul; Thornicroft, Graham; Henderson, Claire

    2013-04-01

    Better newspaper coverage of mental health-related issues is a target for the Time to Change (TTC) anti-stigma programme in England, whose population impact may be influenced by how far concurrent media coverage perpetuates stigma and discrimination. To compare English newspaper coverage of mental health-related topics each year of the TTC social marketing campaign (2009-2011) with baseline coverage in 2008. Content analysis was performed on articles in 27 local and national newspapers on two randomly chosen days each month. There was a significant increase in the proportion of anti-stigmatising articles between 2008 and 2011. There was no concomitant proportional decrease in stigmatising articles, and the contribution of mixed or neutral elements decreased. These findings provide promising results on improvements in press reporting of mental illness during the TTC programme in 2009-2011, and a basis for guidance to newspaper journalists and editors on reporting mental illness.

  3. WE-EF-BRA-07: High Performance Preclinical Irradiation Through Optimized Dual Focal Spot Dose Painting and Online Virtual Isocenter Radiation Field Targeting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stewart, J; Princess Margaret Cancer Centre, University Health Network, Toronto, CA; Lindsay, P

    Purpose: Advances in radiotherapy practice facilitated by collimation systems to shape radiation fields and image guidance to target these conformal beams have motivated proposals for more complex dose patterns to improve the therapeutic ratio. Recent progress in small animal radiotherapy platforms has provided the foundation to validate the efficacy of such interventions, but robustly delivering heterogeneous dose distributions at the scale and accuracy demanded by preclinical studies remains challenging. This work proposes a dual focal spot optimization method to paint spatially heterogeneous dose regions and an online virtual isocenter targeting method to accurately target the dose distributions. Methods: Two-dimensional dosemore » kernels were empirically measured for the 1 mm diameter circular collimator with radiochromic film in a solid water phantom for the small and large x-ray focal spots on the X-RAD 225Cx microirradiator. These kernels were used in an optimization framework which determined a set of animal stage positions, beam-on times, and focal spot settings to optimally deliver a given desired dose distribution. An online method was developed which defined a virtual treatment isocenter based on a single image projection of the collimated radiation field. The method was demonstrated by optimization of a 6 mm circular 2 Gy target adjoining a 4 mm semicircular avoidance region. Results: The dual focal spot technique improved the optimized dose distribution with the proportion of avoidance region receiving more than 0.5 Gy reduced by 40% compared to the large focal spot technique. Targeting tests performed by irradiating ball bearing targets on radiochromic film pieced revealed the online targeting method improved the three-dimensional accuracy from 0.48 mm to 0.15 mm. Conclusion: The dual focal spot optimization and online virtual isocenter targeting framework is a robust option for delivering dose at the preclinical level and provides a new

  4. Progressive universalism? The impact of targeted coverage on health care access and expenditures in Peru.

    PubMed

    Neelsen, Sven; O'Donnell, Owen

    2017-12-01

    Like other countries seeking a progressive path to universalism, Peru has attempted to reduce inequalities in access to health care by granting the poor entitlement to tax-financed basic care without charge. We identify the impact of this policy by comparing the target population's change in health care utilization with that of poor adults already covered through employment-based insurance. There are positive effects on receipt of ambulatory care and medication that are largest among the elderly and the poorest. The probability of getting formal health care when sick is increased by almost two fifths, but the likelihood of being unable to afford treatment is reduced by more than a quarter. Consistent with the shallow coverage offered, there is no impact on use of inpatient care. Neither is there any effect on average out-of-pocket health care expenditure, but medical spending is reduced by up to 25% in the top quarter of the distribution. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  5. Automated treatment planning for a dedicated multi-source intra-cranial radiosurgery treatment unit accounting for overlapping structures and dose homogeneity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghobadi, Kimia; Ghaffari, Hamid R.; Aleman, Dionne M.

    2013-09-15

    Purpose: The purpose of this work is to advance the two-step approach for Gamma Knife{sup ®} Perfexion™ (PFX) optimization to account for dose homogeneity and overlap between the planning target volume (PTV) and organs-at-risk (OARs).Methods: In the first step, a geometry-based algorithm is used to quickly select isocentre locations while explicitly accounting for PTV-OARs overlaps. In this approach, the PTV is divided into subvolumes based on the PTV-OARs overlaps and the distance of voxels to the overlaps. Only a few isocentres are selected in the overlap volume, and a higher number of isocentres are carefully selected among voxels that aremore » immediately close to the overlap volume. In the second step, a convex optimization is solved to find the optimal combination of collimator sizes and their radiation duration for each isocentre location.Results: This two-step approach is tested on seven clinical cases (comprising 11 targets) for which the authors assess coverage, OARs dose, and homogeneity index and relate these parameters to the overlap fraction for each case. In terms of coverage, the mean V{sub 99} for the gross target volume (GTV) was 99.8% while the V{sub 95} for the PTV averaged at 94.6%, thus satisfying the clinical objectives of 99% for GTV and 95% for PTV, respectively. The mean relative dose to the brainstem was 87.7% of the prescription dose (with maximum 108%), while on average, 11.3% of the PTV overlapped with the brainstem. The mean beam-on time per fraction per dose was 8.6 min with calibration dose rate of 3.5 Gy/min, and the computational time averaged at 205 min. Compared with previous work involving single-fraction radiosurgery, the resulting plans were more homogeneous with average homogeneity index of 1.18 compared to 1.47.Conclusions: PFX treatment plans with homogeneous dose distribution can be achieved by inverse planning using geometric isocentre selection and mathematical modeling and optimization techniques. The quality of

  6. Vaccination coverage and its determinants among migrant children in Guangdong, China

    PubMed Central

    2014-01-01

    Background Guangdong province attracted more than 31 million migrants in 2010. But few studies were performed to estimate the complete and age-appropriate immunization coverage and determine risk factors of migrant children. Methods 1610 migrant children aged 12–59 months from 70 villages were interviewed in Guangdong. Demographic characteristics, primary caregiver’s knowledge and attitude toward immunization, and child’s immunization history were obtained. UTD and age-appropriate immunization rates for the following five vaccines and the overall series (1:3:3:3:1 immunization series) were assessed: one dose of BCG, three doses of DTP, OPV and HepB, one dose of MCV. Risk factors for not being UTD for the 1:3:3:3:1 immunization series were explored. Results For each antigen, the UTD immunization rate was above 71%, but the age-appropriate immunization rates for BCG, HepB, OPV, DPT and MCV were only 47.8%, 45.1%, 47.1%, 46.8% and 37.2%, respectively. The 1st dose was most likely to be delayed within them. For the 1:3:3:3:1 immunization series, the UTD immunization rate and age-appropriate immunization rate were 64.9% and 12.4% respectively. Several factors as below were significantly associated with UTD immunization. The primary caregiver’s determinants were their occupation, knowledge and attitude toward immunization. The child’s determinants were sex, Hukou, birth place, residential buildings and family income. Conclusions Alarmingly low immunization coverage of migrant children should be closely monitored by NIISS. Primary caregiver and child’s determinants should be considered when taking measures. Strategies to strengthen active out-reach activities and health education for primary caregivers needed to be developed to improve their immunization coverage. PMID:24568184

  7. SU-E-J-110: Dosimetric Analysis of Respiratory Motion Based On Four-Dimensional Dose Accumulation in Liver Stereotactic Body Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kang, S; Kim, D; Kim, T

    2015-06-15

    Purpose: Respiratory motion in thoracic and abdominal region could lead to significant underdosing of target and increased dose to healthy tissues. The aim of this study is to evaluate the dosimetric effect of respiratory motion in conventional 3D dose by comparing 4D deformable dose in liver stereotactic body radiotherapy (SBRT). Methods: Five patients who had previously treated liver SBRT were included in this study. Four-dimensional computed tomography (4DCT) images with 10 phases for all patients were acquired on multi-slice CT scanner (Siemens, Somatom definition). Conventional 3D planning was performed using the average intensity projection (AIP) images. 4D dose accumulation wasmore » calculated by summation of dose distribution for all phase images of 4DCT using deformable image registration (DIR) . The target volume and normal organs dose were evaluated with the 4D dose and compared with those from 3D dose. And also, Index of achievement (IOA) which assesses the consistency between planned dose and prescription dose was used to compare target dose distribution between 3D and 4D dose. Results: Although the 3D dose calculation considered the moving target coverage, significant differences of various dosimetric parameters between 4D and 3D dose were observed in normal organs and PTV. The conventional 3D dose overestimated dose to PTV, however, there was no significant difference for GTV. The average difference of IOA which become ‘1’ in an ideal case was 3.2% in PTV. The average difference of liver and duodenum was 5% and 16% respectively. Conclusion: 4D dose accumulation which can provide dosimetric effect of respiratory motion has a possibility to predict the more accurate delivered dose to target and normal organs and improve treatment accuracy. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by

  8. [Estimated mammogram coverage in Goiás State, Brazil].

    PubMed

    Corrêa, Rosangela da Silveira; Freitas-Júnior, Ruffo; Peixoto, João Emílio; Rodrigues, Danielle Cristina Netto; Lemos, Maria Eugênia da Fonseca; Marins, Lucy Aparecida Parreira; Silveira, Erika Aparecida da

    2011-09-01

    This cross-sectional study aimed to estimate mammogram coverage in the State of Goiás, Brazil, describing the supply, demand, and variations in different age groups, evaluating 98 mammography services as observational units. We estimated the mammogram rates by age group and type of health service, as well as the number of tests required to cover 70% and 100% of the target population. We assessed the association between mammograms, geographical distribution of mammography machines, type of service, and age group. Full coverage estimates, considering 100% of women in the 40-69 and 50-69-year age brackets, were 61% and 66%, of which the Brazilian Unified National Health System provided 13% and 14%, respectively. To achieve 70% coverage, 43,424 additional mammograms would be needed. All the associations showed statistically significant differences (p < 0.001). We conclude that mammogram coverage is unevenly distributed in the State of Goiás and that fewer tests are performed than required.

  9. High-dose naltrexone therapy for cocaine-alcohol dependence.

    PubMed

    Schmitz, Joy M; Lindsay, Jan A; Green, Charles E; Herin, David V; Stotts, Angela L; Moeller, F Gerard

    2009-01-01

    This randomized, double-blind, placebo-controlled study compared the effects of high-dose (100 mg/d) naltrexone versus placebo in a sample of 87 randomized subjects with both cocaine and alcohol dependence. Medication conditions were crossed with two behavioral therapy platforms that examined whether adding contingency management (CM) that targeted cocaine abstinence would enhance naltrexone effects compared to cognitive behavioral therapy (CBT) without CM. Primary outcome measures for cocaine (urine screens) and alcohol use (timeline followback) were collected thrice-weekly during 12 weeks of treatment. Retention in treatment and medication compliance rates were low. Rates of cocaine use and drinks per day did not differ between treatment groups; however naltrexone did reduce frequency of heavy drinking days, as did CBT without CM. Notably, adding CM to CBT did not enhance treatment outcomes. These weak findings suggest that pharmacological and behavioral interventions that have shown efficacy in the treatment of a single drug dependence disorder may not provide the coverage needed when targeting dual drug dependence.

  10. Corneal targeted nanoparticles for sustained natamycin delivery and their PK/PD indices: an approach to reduce dose and dosing frequency.

    PubMed

    Chandasana, Hardik; Prasad, Yarra Durga; Chhonker, Yashpal S; Chaitanya, Telaprolu K; Mishra, Nripendra N; Mitra, Kalyan; Shukla, Praveen K; Bhatta, Rabi S

    2014-12-30

    Natamycin is the only approved medication for the treatment of mycotic keratitis. Current dosage regimen include one drop of natamycin suspension (5% w/v) instilled in the conjunctival sac at hourly or two hourly intervals for several days which has poor patient compliance. The purpose of the present study was to design a corneal targeted nanoformulation in order to reduce dose and dosing frequency of natamycin and evaluate its pharmacokinetic/pharmacodynamic indices in comparison with clinical marketed preparation. The nanoparticles prepared by nanoprecipitation method were in nanometer size range with high entrapment efficiency and positive surface charge. In-vitro release studies indicated prolonged release of natamycin up to 8h. In-vitro antifungal activity was comparable with marketed preparation. The performance of nanoformulations was evaluated in rabbit eyes. The concentration of natamycin in tear fluid was determined by using LC-MS/MS. The pharmacokinetic parameters such as area under the curve, t½ and mean residence time were significantly higher and clearance was significantly lower for nanoformulations with that of marketed preparation. The optimized dosing schedule to maintain natamycin concentration above tenfold of MIC90 was one instillation in every 5h. Moreover, 1/5th dose reduction of nanoformulation was also effective. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Marked increase in measles vaccination coverage among young adults in Switzerland: a campaign or cohort effect?

    PubMed

    Altpeter, Ekkehardt; Wymann, Monica N; Richard, Jean-Luc; Mäusezahl-Feuz, Mirjam

    2018-06-01

    To evaluate the impact of the Swiss measles elimination strategy-including a mass media campaign-on vaccination coverage and awareness among young adults aged 20-29 years. Comparison of the results of two cross-sectional population surveys in 2012 and 2015. Documented vaccination coverage increased from 77 to 88% for two doses of measles vaccine. Major determinants of complete vaccination were survey year, birth cohort, sex and the absence of prior measles disease. If birth cohort and prior history of measles disease are included as factors in a multivariate model, the difference between 2012 and 2015 vanishes. The marked increase in complete measles vaccination coverage is due to a cohort effect, owing to the introduction of the second dose of vaccine in 1996. Most of the vaccinations were administered before the national strategy was implemented and vaccination catch-ups did not increase during the campaign in young adults. Nevertheless, this study provides evidence of an improvement in the awareness of measles and measles vaccination in young adults, which may result in an impact on measles vaccination coverage in the near future.

  12. Strategies to improve treatment coverage in community-based public health programs: A systematic review of the literature.

    PubMed

    Deardorff, Katrina V; Rubin Means, Arianna; Ásbjörnsdóttir, Kristjana H; Walson, Judd

    2018-02-01

    Community-based public health campaigns, such as those used in mass deworming, vitamin A supplementation and child immunization programs, provide key healthcare interventions to targeted populations at scale. However, these programs often fall short of established coverage targets. The purpose of this systematic review was to evaluate the impact of strategies used to increase treatment coverage in community-based public health campaigns. We systematically searched CAB Direct, Embase, and PubMed archives for studies utilizing specific interventions to increase coverage of community-based distribution of drugs, vaccines, or other public health services. We identified 5,637 articles, from which 79 full texts were evaluated according to pre-defined inclusion and exclusion criteria. Twenty-eight articles met inclusion criteria and data were abstracted regarding strategy-specific changes in coverage from these sources. Strategies used to increase coverage included community-directed treatment (n = 6, pooled percent change in coverage: +26.2%), distributor incentives (n = 2, +25.3%), distribution along kinship networks (n = 1, +24.5%), intensified information, education, and communication activities (n = 8, +21.6%), fixed-point delivery (n = 1, +21.4%), door-to-door delivery (n = 1, +14.0%), integrated service distribution (n = 9, +12.7%), conversion from school- to community-based delivery (n = 3, +11.9%), and management by a non-governmental organization (n = 1, +5.8%). Strategies that target improving community member ownership of distribution appear to have a large impact on increasing treatment coverage. However, all strategies used to increase coverage successfully did so. These results may be useful to National Ministries, programs, and implementing partners in optimizing treatment coverage in community-based public health programs.

  13. Strategies to improve treatment coverage in community-based public health programs: A systematic review of the literature

    PubMed Central

    2018-01-01

    Background Community-based public health campaigns, such as those used in mass deworming, vitamin A supplementation and child immunization programs, provide key healthcare interventions to targeted populations at scale. However, these programs often fall short of established coverage targets. The purpose of this systematic review was to evaluate the impact of strategies used to increase treatment coverage in community-based public health campaigns. Methodology/ principal findings We systematically searched CAB Direct, Embase, and PubMed archives for studies utilizing specific interventions to increase coverage of community-based distribution of drugs, vaccines, or other public health services. We identified 5,637 articles, from which 79 full texts were evaluated according to pre-defined inclusion and exclusion criteria. Twenty-eight articles met inclusion criteria and data were abstracted regarding strategy-specific changes in coverage from these sources. Strategies used to increase coverage included community-directed treatment (n = 6, pooled percent change in coverage: +26.2%), distributor incentives (n = 2, +25.3%), distribution along kinship networks (n = 1, +24.5%), intensified information, education, and communication activities (n = 8, +21.6%), fixed-point delivery (n = 1, +21.4%), door-to-door delivery (n = 1, +14.0%), integrated service distribution (n = 9, +12.7%), conversion from school- to community-based delivery (n = 3, +11.9%), and management by a non-governmental organization (n = 1, +5.8%). Conclusions/significance Strategies that target improving community member ownership of distribution appear to have a large impact on increasing treatment coverage. However, all strategies used to increase coverage successfully did so. These results may be useful to National Ministries, programs, and implementing partners in optimizing treatment coverage in community-based public health programs. PMID:29420534

  14. Factors influencing full immunization coverage among 12-23 months of age children in Ethiopia: evidence from the national demographic and health survey in 2011.

    PubMed

    Lakew, Yihunie; Bekele, Alemayhu; Biadgilign, Sibhatu

    2015-07-30

    Immunization remains one of the most important public health interventions to reduce child morbidity and mortality. The 2011 national demographic and health survey (DHS) indicated low full immunization coverage among children aged 12-23 months in Ethiopia. Factors contributing to the low coverage of immunization have been poorly understood. The aim of this study was to identify factors associated with full immunization coverage among children aged 12-23 months in Ethiopia. This study used the 2011 Ethiopian demographic and health survey data. The survey was cross sectional by design and used a multistage cluster sampling procedure. A total of 1,927 mothers with children of 12-23 months of age were extracted from the children's dataset. Mothers' self-reported data and observations of vaccination cards were used to determine vaccine coverage. An adjusted odds ratio (AOR) with 95% confidence intervals (CI) was used to outline the independent predictors. The prevalence of fully immunized children was 24.3%. Specific vaccination coverage for three doses of DPT, three doses of polio, measles and BCG were 36.5%, 44.3%, 55.7% and 66.3%, respectively. The multivariable analysis showed that sources of information from vaccination card [AOR 95% CI; 7.7 (5.95-10.06)], received postnatal check-up within two months after birth [AOR 95% CI; 1.8 (1.28-2.56)], women's awareness of community conversation program [AOR 95% CI; 1.9 (1.44-2.49)] and women in the rich wealth index [AOR 95% CI; 1.4 (1.06-1.94)] were the predictors of full immunization coverage. Women from Afar [AOR 95% CI; 0.07 (0.01-0.68)], Amhara [AOR 95% CI; 0.33 (0.13-0.81)], Oromiya [AOR 95% CI; 0.15 (0.06-0.37)], Somali [AOR 95% CI; 0.15 (0.04-0.55)] and Southern Nation and Nationalities People administrative regions [AOR 95% CI; 0.35 (0.14-0.87)] were less likely to fully vaccinate their children. The overall full immunization coverage in Ethiopia was considerably low as compared to the national target set (66

  15. Influence of different treatment techniques on radiation dose to the LAD coronary artery

    PubMed Central

    Nieder, Carsten; Schill, Sabine; Kneschaurek, Peter; Molls, Michael

    2007-01-01

    Background The purpose of this proof-of-principle study was to test the ability of an intensity-modulated radiotherapy (IMRT) technique to reduce the radiation dose to the heart plus the left ventricle and a coronary artery. Radiation-induced heart disease might be a serious complication in long-term cancer survivors. Methods Planning CT scans from 6 female patients were available. They were part of a previous study of mediastinal IMRT for target volumes used in lymphoma treatment that included 8 patients and represent all cases where the left anterior descending coronary artery (LAD) could be contoured. We compared 6 MV AP/PA opposed fields to a 3D conformal 4-field technique and an optimised 7-field step-and-shoot IMRT technique and evaluated DVH's for several structures. The planning system was BrainSCAN 5.21 (BrainLAB, Heimstetten, Germany). Results IMRT maintained target volume coverage but resulted in better dose reduction to the heart, left ventricle and LAD than the other techniques. Selective dose reduction could be accomplished, although not to the degree initially attempted. The median LAD dose was approximately 50% lower with IMRT. In 5 out of 6 patients, IMRT was the best technique with regard to heart sparing. Conclusion IMRT techniques are able to reduce the radiation dose to the heart. In addition to dose reduction to whole heart, individualised dose distributions can be created, which spare, e.g., one ventricle plus one of the coronary arteries. Certain patients with well-defined vessel pathology might profit from an approach of general heart sparing with further selective dose reduction, accounting for the individual aspects of pre-existing damage. PMID:17547777

  16. SU-F-T-157: Physics Considerations Regarding Dosimetric Accuracy of Analytical Dose Calculations for Small Field Proton Therapy: A Monte Carlo Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geng, C; Nanjing University of Aeronautics and Astronautics, Nanjing; Daartz, J

    Purpose: To evaluate the accuracy of dose calculations by analytical dose calculation methods (ADC) for small field proton therapy in a gantry based passive scattering facility. Methods: 50 patients with intra-cranial disease were evaluated in the study. Treatment plans followed standard prescription and optimization procedures of proton stereotactic radiosurgery. Dose distributions calculated with the Monte Carlo (MC) toolkit TOPAS were used to represent delivered treatments. The MC dose was first adjusted using the output factor (OF) applied clinically. This factor is determined from the field size and the prescribed range. We then introduced a normalization factor to measure the differencemore » in mean dose between the delivered dose (MC dose with OF) and the dose calculated by ADC for each beam. The normalization was determined by the mean dose of the center voxels of the target area. We compared delivered dose distributions and those calculated by ADC in terms of dose volume histogram parameters and beam range distributions. Results: The mean target dose for a whole treatment is generally within 5% comparing delivered dose (MC dose with OF) and ADC dose. However, the differences can be as great as 11% for shallow and small target treated with a thick range compensator. Applying the normalization factor to the MC dose with OF can reduce the mean dose difference to less than 3%. Considering range uncertainties, the generally applied margins (3.5% of the prescribed range + 1mm) to cover uncertainties in range might not be sufficient to guarantee tumor coverage. The range difference for R90 (90% distal dose falloff) is affected by multiple factors, such as the heterogeneity index. Conclusion: This study indicates insufficient accuracy calculating proton doses using ADC. Our results suggest that uncertainties of target doses are reduced using MC techniques, improving the dosimetric accuracy for proton stereotactic radiosurgery. The work was supported by NIH

  17. Patient-specific dose estimation for pediatric abdomen-pelvis CT

    NASA Astrophysics Data System (ADS)

    Li, Xiang; Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Frush, Donald P.

    2009-02-01

    The purpose of this study is to develop a method for estimating patient-specific dose from abdomen-pelvis CT examinations and to investigate dose variation across patients in the same weight group. Our study consisted of seven pediatric patients in the same weight/protocol group, for whom full-body computer models were previously created based on the patients' CT data obtained for clinical indications. Organ and effective dose of these patients from an abdomen-pelvis scan protocol (LightSpeed VCT scanner, 120-kVp, 85-90 mA, 0.4-s gantry rotation period, 1.375-pitch, 40-mm beam collimation, and small body scan field-of-view) was calculated using a Monte Carlo program previously developed and validated for the same CT system. The seven patients had effective dose of 2.4-2.8 mSv, corresponding to normalized effective dose of 6.6-8.3 mSv/100mAs (coefficient of variation: 7.6%). Dose variations across the patients were small for large organs in the scan coverage (mean: 6.6%; range: 4.9%-9.2%), larger for small organs in the scan coverage (mean: 10.3%; range: 1.4%-15.6%), and the largest for organs partially or completely outside the scan coverage (mean: 14.8%; range: 5.7%-27.7%). Normalized effective dose correlated strongly with body weight (correlation coefficient: r = -0.94). Normalized dose to the kidney and the adrenal gland correlated strongly with mid-liver equivalent diameter (kidney: r = -0.97; adrenal glands: r = -0.98). Normalized dose to the small intestine correlated strongly with mid-intestine equivalent diameter (r = -0.97). These strong correlations suggest that patient-specific dose may be estimated for any other child in the same size group who undergoes the abdomen-pelvis scan.

  18. Sources and Coverage of Medical News on Front Pages of US Newspapers

    PubMed Central

    Lai, William Y. Y.; Lane, Trevor; Jones, Alison

    2009-01-01

    Background Medical news that appears on newspaper front pages is intended to reach a wide audience, but how this type of medical news is prepared and distributed has not been systematically researched. We thus quantified the level of visibility achieved by front-page medical stories in the United States and analyzed their news sources. Methodology Using the online resource Newseum, we investigated front-page newspaper coverage of four prominent medical stories, and a high-profile non-medical news story as a control, reported in the US in 2007. Two characteristics were quantified by two raters: which newspaper titles carried each target front-page story (interrater agreement, >96%; kappa, >0.92) and the news sources of each target story (interrater agreement, >94%; kappa, >0.91). National rankings of the top 200 US newspapers by audited circulation were used to quantify the extent of coverage as the proportion of the total circulation of ranked newspapers in Newseum. Findings In total, 1630 front pages were searched. Each medical story appeared on the front pages of 85 to 117 (67.5%–78.7%) ranked newspaper titles that had a cumulative daily circulation of 23.1 to 33.4 million, or 61.8% to 88.4% of all newspapers. In contrast, the non-medical story achieved front-page coverage in 152 (99.3%) newspaper titles with a total circulation of 41.0 million, or 99.8% of all newspapers. Front-page medical stories varied in their sources, but the Washington Post, Los Angeles Times, New York Times and the Associated Press together supplied 61.7% of the total coverage of target front-page medical stories. Conclusion Front-page coverage of medical news from different sources is more accurately revealed by analysis of circulation counts rather than of newspaper titles. Journals wishing to widen knowledge of research news and organizations with important health announcements should target at least the four dominant media organizations identified in this study. PMID:19724643

  19. Angular distributions of absorbed dose of Bremsstrahlung and secondary electrons induced by 18-, 28- and 38-MeV electron beams in thick targets.

    PubMed

    Takada, Masashi; Kosako, Kazuaki; Oishi, Koji; Nakamura, Takashi; Sato, Kouichi; Kamiyama, Takashi; Kiyanagi, Yoshiaki

    2013-03-01

    Angular distributions of absorbed dose of Bremsstrahlung photons and secondary electrons at a wide range of emission angles from 0 to 135°, were experimentally obtained using an ion chamber with a 0.6 cm(3) air volume covered with or without a build-up cap. The Bremsstrahlung photons and electrons were produced by 18-, 28- and 38-MeV electron beams bombarding tungsten, copper, aluminium and carbon targets. The absorbed doses were also calculated from simulated photon and electron energy spectra by multiplying simulated response functions of the ion chambers, simulated with the MCNPX code. Calculated-to-experimental (C/E) dose ratios obtained are from 0.70 to 1.57 for high-Z targets of W and Cu, from 15 to 135° and the C/E range from 0.6 to 1.4 at 0°; however, the values of C/E for low-Z targets of Al and C are from 0.5 to 1.8 from 0 to 135°. Angular distributions at the forward angles decrease with increasing angles; on the other hand, the angular distributions at the backward angles depend on the target species. The dependences of absorbed doses on electron energy and target thickness were compared between the measured and simulated results. The attenuation profiles of absorbed doses of Bremsstrahlung beams at 0, 30 and 135° were also measured.

  20. Coverage Gains After the Affordable Care Act Among the Uninsured in Minnesota.

    PubMed

    Call, Kathleen Thiede; Lukanen, Elizabeth; Spencer, Donna; Alarcón, Giovann; Kemmick Pintor, Jessie; Baines Simon, Alisha; Gildemeister, Stefan

    2015-11-01

    We determined whether and how Minnesotans who were uninsured in 2013 gained health insurance coverage in 2014, 1 year after the Affordable Care Act (ACA) expanded Medicaid coverage and enrollment. Insurance status and enrollment experiences came from the Minnesota Health Insurance Transitions Study (MH-HITS), a follow-up telephone survey of children and adults in Minnesota who had no health insurance in the fall of 2013. ACA had a tempered success in Minnesota. Outreach and enrollment efforts were effective; one half of those previously uninsured gained coverage, although many reported difficulty signing up (nearly 62%). Of the previously uninsured who gained coverage, 44% obtained their coverage through MNsure, Minnesota's insurance marketplace. Most of those who remained uninsured heard of MNsure and went to the Web site. Many still struggled with the enrollment process or reported being deterred by the cost of coverage. Targeting outreach, simplifying the enrollment process, focusing on affordability, and continuing funding for in-person assistance will be important in the future.

  1. Financial incentives to encourage healthy behaviour: an analysis of UK media coverage

    PubMed Central

    Parke, Hannah; Ashcroft, Richard; Brown, Rebecca; Marteau, Theresa M; Seale, Clive

    2011-01-01

    Abstract Background  Policies to use financial incentives to encourage healthy behaviour are controversial. Much of this controversy is played out in the mass media, both reflecting and shaping public opinion. Objective  To describe UK mass media coverage of incentive schemes, comparing schemes targeted at different client groups and assessing the relative prominence of the views of different interest groups. Design  Thematic content analysis. Subjects  National and local news coverage in newspapers, news media targeted at health‐care providers and popular websites between January 2005 and February 2010. Setting  UK mass media. Results  The study included 210 articles. Fifteen separate arguments favourable towards schemes, and 19 unfavourable, were identified. Overall, coverage was more favourable than unfavourable, although most articles reported a mix of views. Arguments about the prevalence and seriousness of the health problems targeted by incentive schemes were uncontested. Moral and ethical objections to such schemes were common, focused in particular on recipients such as drug users or the overweight who were already stereotyped as morally deficient, and these arguments were largely uncontested. Arguments about the effectiveness of schemes and their potential for benefit or harm were areas of greater contestation. Government, public health and other health‐care provider interests dominated favourable coverage; opposition came from rival politicians, taxpayers’ representatives, certain charities and from some journalists themselves. Conclusions  Those promoting incentive schemes for people who might be regarded as ‘undeserving’ should plan a media strategy that anticipates their public reception. PMID:21771227

  2. SU-E-T-578: On Definition of Minimum and Maximum Dose for Target Volume

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gong, Y; Yu, J; Xiao, Y

    Purpose: This study aims to investigate the impact of different minimum and maximum dose definitions in radiotherapy treatment plan quality evaluation criteria by using tumor control probability (TCP) models. Methods: Dosimetric criteria used in RTOG 1308 protocol are used in the investigation. RTOG 1308 is a phase III randomized trial comparing overall survival after photon versus proton chemoradiotherapy for inoperable stage II-IIIB NSCLC. The prescription dose for planning target volume (PTV) is 70Gy. Maximum dose (Dmax) should not exceed 84Gy and minimum dose (Dmin) should not go below 59.5Gy in order for the plan to be “per protocol” (satisfactory).A mathematicalmore » model that simulates the characteristics of PTV dose volume histogram (DVH) curve with normalized volume is built. The Dmax and Dmin are noted as percentage volumes Dη% and D(100-δ)%, with η and d ranging from 0 to 3.5. The model includes three straight line sections and goes through four points: D95%= 70Gy, Dη%= 84Gy, D(100-δ)%= 59.5 Gy, and D100%= 0Gy. For each set of η and δ, the TCP value is calculated using the inhomogeneously irradiated tumor logistic model with D50= 74.5Gy and γ50=3.52. Results: TCP varies within 0.9% with η; and δ values between 0 and 1. With η and η varies between 0 and 2, TCP change was up to 2.4%. With η and δ variations from 0 to 3.5, maximum of 8.3% TCP difference is seen. Conclusion: When defined maximum and minimum volume varied more than 2%, significant TCP variations were seen. It is recommended less than 2% volume used in definition of Dmax or Dmin for target dosimetric evaluation criteria. This project was supported by NIH grants U10CA180868, U10CA180822, U24CA180803, U24CA12014 and PA CURE Grant.« less

  3. Country-level predictors of vaccination coverage and inequalities in Gavi-supported countries.

    PubMed

    Arsenault, Catherine; Johri, Mira; Nandi, Arijit; Mendoza Rodríguez, José M; Hansen, Peter M; Harper, Sam

    2017-04-25

    Important inequalities in childhood vaccination coverage persist between countries and population groups. Understanding why some countries achieve higher and more equitable levels of coverage is crucial to redress these inequalities. In this study, we explored the country-level determinants of (1) coverage of the third dose of diphtheria-tetanus-pertussis- (DTP3) containing vaccine and (2) within-country inequalities in DTP3 coverage in 45 countries supported by Gavi, the Vaccine Alliance. We used data from the most recent Demographic and Health Surveys (DHS) conducted between 2005 and 2014. We measured national DTP3 coverage and the slope index of inequality in DTP3 coverage with respect to household wealth, maternal education, and multidimensional poverty. We collated data on country health systems, health financing, governance and geographic and sociocultural contexts from published sources. We used meta-regressions to assess the relationship between these country-level factors and variations in DTP3 coverage and inequalities. To validate our findings, we repeated these analyses for coverage with measles-containing vaccine (MCV). We found considerable heterogeneity in DTP3 coverage and in the magnitude of inequalities across countries. Results for MCV were consistent with those from DTP3. Political stability, gender equality and smaller land surface were important predictors of higher and more equitable levels of DTP3 coverage. Inequalities in DTP3 coverage were also lower in countries receiving more external resources for health, with lower rates of out-of-pocket spending and with higher national coverage. Greater government spending on heath and lower linguistic fractionalization were also consistent with better vaccination outcomes. Improving vaccination coverage and reducing inequalities requires that policies and programs address critical social determinants of health including geographic and social exclusion, gender inequality and the availability of

  4. Is universal health coverage the practical expression of the right to health care?

    PubMed Central

    2014-01-01

    The present Millennium Development Goals are set to expire in 2015 and their next iteration is now being discussed within the international community. With regards to health, the World Health Organization proposes universal health coverage as a ‘single overarching health goal’ for the next iteration of the Millennium Development Goals. The present Millennium Development Goals have been criticised for being ‘duplicative’ or even ‘competing alternatives’ to international human rights law. The question then arises, if universal health coverage would indeed become the single overarching health goal, replacing the present health-related Millennium Development Goals, would that be more consistent with the right to health? The World Health Organization seems to have anticipated the question, as it labels universal health coverage as “by definition, a practical expression of the concern for health equity and the right to health”. Rather than waiting for the negotiations to unfold, we thought it would be useful to verify this contention, using a comparative normative analysis. We found that – to be a practical expression of the right to health – at least one element is missing in present authoritative definitions of universal health coverage: a straightforward confirmation that international assistance is essential, not optional. But universal health coverage is a ‘work in progress’. A recent proposal by the United Nations Sustainable Development Solutions Network proposed universal health coverage with a set of targets, including a target for international assistance, which would turn universal health coverage into a practical expression of the right to health care. PMID:24559232

  5. Is universal health coverage the practical expression of the right to health care?

    PubMed

    Ooms, Gorik; Latif, Laila A; Waris, Attiya; Brolan, Claire E; Hammonds, Rachel; Friedman, Eric A; Mulumba, Moses; Forman, Lisa

    2014-02-24

    The present Millennium Development Goals are set to expire in 2015 and their next iteration is now being discussed within the international community. With regards to health, the World Health Organization proposes universal health coverage as a 'single overarching health goal' for the next iteration of the Millennium Development Goals.The present Millennium Development Goals have been criticised for being 'duplicative' or even 'competing alternatives' to international human rights law. The question then arises, if universal health coverage would indeed become the single overarching health goal, replacing the present health-related Millennium Development Goals, would that be more consistent with the right to health? The World Health Organization seems to have anticipated the question, as it labels universal health coverage as "by definition, a practical expression of the concern for health equity and the right to health".Rather than waiting for the negotiations to unfold, we thought it would be useful to verify this contention, using a comparative normative analysis. We found that--to be a practical expression of the right to health--at least one element is missing in present authoritative definitions of universal health coverage: a straightforward confirmation that international assistance is essential, not optional.But universal health coverage is a 'work in progress'. A recent proposal by the United Nations Sustainable Development Solutions Network proposed universal health coverage with a set of targets, including a target for international assistance, which would turn universal health coverage into a practical expression of the right to health care.

  6. Adolescent vaccination: coverage achieved by ages 13-15 years, and vaccinations received as recommended during ages 11-12 years, National Health Interview Survey 1997-2003.

    PubMed

    McCauley, Mary Mason; Stokley, Shannon; Stevenson, John; Fishbein, Daniel B

    2008-12-01

    To present progress toward Healthy People 2010 vaccination objectives for adolescents aged 13-15 years, and to determine how much catch-up and routine vaccination was administered at the recommended ages of 11-12 years. Data from the 1997-2003 National Health Interview Survey were evaluated. In the first analysis, vaccination coverage levels for adolescents aged 13-15 years were determined for each survey year. Main outcome measures include the percent of adolescents who had received the three-dose hepatitis B vaccine (Hep B) series, the two-dose measles/mumps/rubella vaccine (MMR) series, the tetanus and diphtheria toxoids (Td) booster, and one dose of varicella vaccine. In the second analysis, data from all survey years were combined and vaccination dates were analyzed to determine the percentage of adolescents who were missing any vaccines at ages 11-12 and received them at that age. Data for varicella vaccine were sufficient only for the first analysis. Among the approximately 15%-20% of respondents who reported vaccination history from records in the home and who were reporting on a 13-15-year-old, coverage with three doses of Hep B increased significantly during 1997-2001, from 15.2% to 55.0%. Coverage with MMR and Td fluctuated, with no significant increase; highs were 76.7% for MMR in 2003 and 36.2% for Td in 2002. Examination of vaccination dates for all surveyed adolescents showed that among 11-12-year-olds who needed catch-up vaccine, 0.6%-31.3% were brought up to date for Hep B and 22.1%-31.8% were brought up to date for MMR. For Td, 2.6%-15.4% of 11-12-year-olds who had not previously received Td received the vaccine. Vaccination coverage among adolescents aged 13-15 years was below the Healthy People 2010 goals of 90%, but generally increased over the survey years. However, the suboptimal delivery of needed vaccines during ages 11 and 12 is concerning in light of recent vaccine recommendations targeted at this age. Continuing to focus on strategies to

  7. 42 CFR 436.229 - Optional targeted low-income children.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 4 2011-10-01 2011-10-01 false Optional targeted low-income children. 436.229... Options for Coverage as Categorically Needy Options for Coverage of Families and Children and Aged, Blind, and Disabled Individuals, Including Pregnant Women § 436.229 Optional targeted low-income children...

  8. 42 CFR 436.229 - Optional targeted low-income children.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Optional targeted low-income children. 436.229... Options for Coverage as Categorically Needy Options for Coverage of Families and Children and Aged, Blind, and Disabled Individuals, Including Pregnant Women § 436.229 Optional targeted low-income children...

  9. 42 CFR 436.229 - Optional targeted low-income children.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 4 2013-10-01 2013-10-01 false Optional targeted low-income children. 436.229... Options for Coverage as Categorically Needy Options for Coverage of Families and Children and Aged, Blind, and Disabled Individuals, Including Pregnant Women § 436.229 Optional targeted low-income children...

  10. 42 CFR 436.229 - Optional targeted low-income children.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 4 2012-10-01 2012-10-01 false Optional targeted low-income children. 436.229... Options for Coverage as Categorically Needy Options for Coverage of Families and Children and Aged, Blind, and Disabled Individuals, Including Pregnant Women § 436.229 Optional targeted low-income children...

  11. 42 CFR 436.229 - Optional targeted low-income children.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 4 2014-10-01 2014-10-01 false Optional targeted low-income children. 436.229... Options for Coverage as Categorically Needy Options for Coverage of Families and Children and Aged, Blind, and Disabled Individuals, Including Pregnant Women § 436.229 Optional targeted low-income children...

  12. Vaccination Coverage Cluster Surveys in Middle Dreib – Akkar, Lebanon: Comparison of Vaccination Coverage in Children Aged 12-59 Months Pre- and Post-Vaccination Campaign

    PubMed Central

    Assaad, Ramia; Rebeschini, Arianna; Hamadeh, Randa

    2016-01-01

    Introduction With the high proportion of refugee population throughout Lebanon and continuous population movement, it is sensible to believe that, in particular vulnerable areas, vaccination coverage may not be at an optimal level. Therefore, we assessed the vaccination coverage in children under 5 in a district of the Akkar governorate before and after a vaccination campaign. During the vaccination campaign, conducted in August 2015, 2,509 children were vaccinated. Materials and Methods We conducted a pre- and post-vaccination campaign coverage surveys adapting the WHO EPI cluster survey to the Lebanese MoPH vaccination calendar. Percentages of coverage for each dose of each vaccine were calculated for both surveys. Factors associated with complete vaccination were explored. Results Comparing the pre- with the post-campaign surveys, coverage for polio vaccine increased from 51.9% to 84.3%, for Pentavalent from 49.0% to 71.9%, for MMR from 36.2% to 61.0%, while the percentage of children with fully updated vaccination calendar increased from 32.9% to 53.8%. While Lebanese children were found to be better covered for some antigens compared to Syrians at the first survey, this difference disappeared at the post-campaign survey. Awareness and logistic obstacles were the primary reported causes of not complete vaccination in both surveys. Discussion Vaccination campaigns remain a quick and effective approach to increase vaccination coverage in crisis-affected areas. However, campaigns cannot be considered as a replacement of routine vaccination services to maintain a good level of coverage. PMID:27992470

  13. Targeted nanoparticle delivery of therapeutic antisense microRNAs presensitizes glioblastoma cells to lower effective doses of temozolomide in vitro and in a mouse model.

    PubMed

    Malhotra, Meenakshi; Sekar, Thillai Veerapazham; Ananta, Jeyarama S; Devulapally, Rammohan; Afjei, Rayhaneh; Babikir, Husam A; Paulmurugan, Ramasamy; Massoud, Tarik F

    2018-04-20

    Temozolomide (TMZ) chemotherapy for glioblastoma (GBM) is generally well tolerated at standard doses but it can cause side effects. GBMs overexpress microRNA-21 and microRNA-10b, two known oncomiRs that promote cancer development, progression and resistance to drug treatment. We hypothesized that systemic injection of antisense microRNAs (antagomiR-21 and antagomiR-10b) encapsulated in cRGD-tagged PEG-PLGA nanoparticles would result in high cellular delivery of intact functional antagomiRs, with consequent efficient therapeutic response and increased sensitivity of GBM cells to lower doses of TMZ. We synthesized both targeted and non-targeted nanoparticles, and characterized them for size, surface charge and encapsulation efficiency of antagomiRs. When using targeted nanoparticles in U87MG and Ln229 GBM cells, we showed higher uptake-associated improvement in sensitivity of these cells to lower concentrations of TMZ in medium. Co-inhibition of microRNA-21 and microRNA-10b reduced the number of viable cells and increased cell cycle arrest at G2/M phase upon TMZ treatment. We found a significant increase in expression of key target genes for microRNA-21 and microRNA-10b upon using targeted versus non-targeted nanoparticles. There was also significant reduction in tumor volume when using TMZ after pre-treatment with loaded nanoparticles in human GBM cell xenografts in mice. In vivo targeted nanoparticles plus different doses of TMZ showed a significant therapeutic response even at the lowest dose of TMZ, indicating that preloading cells with antagomiR-21 and antagomiR-10b increases cellular chemosensitivity towards lower TMZ doses. Future clinical applications of this combination therapy may result in improved GBM response by using lower doses of TMZ and reducing nonspecific treatment side effects.

  14. Four-dimensional dose evaluation using deformable image registration in radiotherapy for liver cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoon Jung, Sang; Min Yoon, Sang; Ho Park, Sung

    2013-01-15

    Purpose: In order to evaluate the dosimetric impact of respiratory motion on the dose delivered to the target volume and critical organs during free-breathing radiotherapy, a four-dimensional dose was evaluated using deformable image registration (DIR). Methods: Four-dimensional computed tomography (4DCT) images were acquired for 11 patients who were treated for liver cancer. Internal target volume-based treatment planning and dose calculation (3D dose) were performed using the end-exhalation phase images. The four-dimensional dose (4D dose) was calculated based on DIR of all phase images from 4DCT to the planned image. Dosimetric parameters from the 4D dose, were calculated and compared withmore » those from the 3D dose. Results: There was no significant change of the dosimetric parameters for gross tumor volume (p > 0.05). The increase D{sub mean} and generalized equivalent uniform dose (gEUD) for liver were by 3.1%{+-} 3.3% (p= 0.003) and 2.8%{+-} 3.3% (p= 0.008), respectively, and for duodenum, they were decreased by 15.7%{+-} 11.2% (p= 0.003) and 15.1%{+-} 11.0% (p= 0.003), respectively. The D{sub max} and gEUD for stomach was decreased by 5.3%{+-} 5.8% (p= 0.003) and 9.7%{+-} 8.7% (p= 0.003), respectively. The D{sub max} and gEUD for right kidney was decreased by 11.2%{+-} 16.2% (p= 0.003) and 14.9%{+-} 16.8% (p= 0.005), respectively. For left kidney, D{sub max} and gEUD were decreased by 11.4%{+-} 11.0% (p= 0.003) and 12.8%{+-} 12.1% (p= 0.005), respectively. The NTCP values for duodenum and stomach were decreased by 8.4%{+-} 5.8% (p= 0.003) and 17.2%{+-} 13.7% (p= 0.003), respectively. Conclusions: The four-dimensional dose with a more realistic dose calculation accounting for respiratory motion revealed no significant difference in target coverage and potentially significant change in the physical and biological dosimetric parameters in normal organs during free-breathing treatment.« less

  15. 45 CFR 156.602 - Other coverage that qualifies as minimum essential coverage.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... Coverage offered to students by an institution of higher education (as defined in the Higher Education Act... essential coverage for plan or policy years beginning on or before December 31, 2014. For coverage beginning... essential coverage for plan or policy years beginning on or before December 31, 2014. For coverage beginning...

  16. 45 CFR 156.602 - Other coverage that qualifies as minimum essential coverage.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .... Coverage offered to students by an institution of higher education (as defined in the Higher Education Act... essential coverage for plan or policy years beginning on or before December 31, 2014. For coverage beginning... essential coverage for plan or policy years beginning on or before December 31, 2014. For coverage beginning...

  17. Quantification of interplay and gradient effects for lung stereotactic ablative radiotherapy (SABR) treatments.

    PubMed

    Tyler, Madelaine K

    2016-01-08

    This study quantified the interplay and gradient effects on GTV dose coverage for 3D CRT, dMLC IMRT, and VMAT SABR treatments for target amplitudes of 5-30 mm using 3DVH v3.1 software incorporating 4D Respiratory MotionSim (4D RMS) module. For clinically relevant motion periods (5 s), the interplay effect was small, with deviations in the minimum dose covering the target volume (D99%) of less than ± 2.5% for target amplitudes up to 30 mm. Increasing the period to 60 s resulted in interplay effects of up to ± 15.0% on target D99% dose coverage. The gradient effect introduced by target motion resulted in deviations of up to ± 3.5% in D99% target dose coverage. VMAT treatments showed the largest deviation in dose metrics, which was attributed to the long delivery times in comparison to dMLC IMRT. Retrospective patient analysis indicated minimal interplay and gradient effects for patients treated with dMLC IMRT at the NCCI.

  18. Quantification of interplay and gradient effects for lung stereotactic ablative radiotherapy (SABR) treatments

    PubMed Central

    2016-01-01

    This study quantified the interplay and gradient effects on GTV dose coverage for 3D CRT, dMLC IMRT, and VMAT SABR treatments for target amplitudes of 5–30 mm using 3DVH v3.1 software incorporating 4D Respiratory MotionSim (4D RMS) module. For clinically relevant motion periods (5 s), the interplay effect was small, with deviations in the minimum dose covering the target volume (D99%) of less than ±2.5% for target amplitudes up to 30 mm. Increasing the period to 60 s resulted in interplay effects of up to ±15.0% on target D99% dose coverage. The gradient effect introduced by target motion resulted in deviations of up to ±3.5% in D99% target dose coverage. VMAT treatments showed the largest deviation in dose metrics, which was attributed to the long delivery times in comparison to dMLC IMRT. Retrospective patient analysis indicated minimal interplay and gradient effects for patients treated with dMLC IMRT at the NCCI. PACS numbers: 87.55.km, 87.56.Fc PMID:26894347

  19. Impact of Node Negative Target Volume Delineation on Contralateral Parotid Gland Dose Sparing Using IMRT in Head and Neck Cancer.

    PubMed

    Magnuson, William J; Urban, Erich; Bayliss, R Adam; Harari, Paul M

    2015-06-01

    There is considerable practice variation in treatment of the node negative (N0) contralateral neck in patients with head and neck cancer. In this study, we examined the impact of N0 neck target delineation volume on radiation dose to the contralateral parotid gland. Following institutional review board approval, 12 patients with head and neck cancer were studied. All had indications for treatment of the N0 neck, such as midline base of tongue or soft palate extension or advanced ipsilateral nodal disease. The N0 neck volumes were created using the Radiation Therapy Oncology Group head and neck contouring atlas. The physician-drawn N0 neck clinical target volume (CTV) was expanded by 25% to 200% to generate volume variation, followed by a 3-mm planning target volume (PTV) expansion. Surrounding organs at risk were contoured and complete intensity-modulated radiation therapy plans were generated for each N0 volume expansion. The median N0 target volume drawn by the radiation oncologist measured 93 cm(3) (range 71-145). Volumetric expansion of the N0 CTV by 25% to 200% increased the resultant mean dose to the contralateral parotid gland by 1.4 to 8.5 Gray (Gy). For example, a 4.1-mm increase in the N0 neck CTV translated to a 2.0-Gy dose increase to the parotid, 7.4 mm to a 4.5 Gy dose increase, and 12.5 mm to an 8.5 Gy dose increase, respectively. The treatment volume designated for the N0 neck has profound impact on resultant dose to the contralateral parotid gland. Variations of up to 15 mm are routine across physicians in target contouring, reflecting individual preference and training expertise. Depending on the availability of immobilization and image guidance techniques, experts commonly recommend 3 to 10 mm margin expansions to generate the PTV. Careful attention to the original volume of the N0 neck CTV, as well as expansion margins, is important in achieving effective contralateral gland sparing to reduce the resultant xerostomia and dysguesia that may ensue

  20. Graves' disease radioiodine-therapy: Choosing target absorbed doses for therapy planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willegaignon, J., E-mail: j.willegaignon@gmail.com; Sapienza, M. T.; Coura-Filho, G. B.

    2014-01-15

    and A{sup ~} was determined by the integration of measured {sup 131}I activity in the thyroid gland and based on T{sub eff}, respectively. No statistically significant relationship was found between therapeutic response and patients’ age, administered {sup 131}I activity (MBq), 24-h thyroid {sup 131}I uptake (%) or T{sub eff} (p ≥ 0.064); nonetheless, a good relationship was found between the therapeutic response and m{sub th} (p ≤ 0.035). Conclusions: According to the results of this study, the most effective thyroid absorbed dose to be targeted in GD therapy should not be based on a fixed dose but rather should be individualized based on the patient'sm{sub th} and A{sup ~}. To achieve a therapeutic success (i.e., durable euthyroidism or hypothyroidism) rate of at least 95%, a thyroid absorbed dose of 200 or 330 Gy is required depending on the methodology used for estimating m{sub th} and A{sup ~}.« less

  1. Graves' disease radioiodine-therapy: Choosing target absorbed doses for therapy planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willegaignon, J., E-mail: j.willegaignon@gmail.com; Sapienza, M. T.; Coura-Filho, G. B.

    and A{sup ~} was determined by the integration of measured {sup 131}I activity in the thyroid gland and based on T{sub eff}, respectively. No statistically significant relationship was found between therapeutic response and patients’ age, administered {sup 131}I activity (MBq), 24-h thyroid {sup 131}I uptake (%) or T{sub eff} (p ≥ 0.064); nonetheless, a good relationship was found between the therapeutic response and m{sub th} (p ≤ 0.035). Conclusions: According to the results of this study, the most effective thyroid absorbed dose to be targeted in GD therapy should not be based on a fixed dose but rather should be individualized based on the patient'sm{sub th} and A{sup ~}. To achieve a therapeutic success (i.e., durable euthyroidism or hypothyroidism) rate of at least 95%, a thyroid absorbed dose of 200 or 330 Gy is required depending on the methodology used for estimating m{sub th} and A{sup ~}.« less

  2. Analysis of incidental radiation dose to uninvolved mediastinal/supraclavicular lymph nodes in patients with limited-stage small cell lung cancer treated without elective nodal irradiation.

    PubMed

    Ahmed, Irfan; DeMarco, Marylou; Stevens, Craig W; Fulp, William J; Dilling, Thomas J

    2011-01-01

    Classic teaching states that treatment of limited-stage small cell lung cancer (L-SCLC) requires large treatment fields covering the entire mediastinum. However, a trend in modern thoracic radiotherapy is toward more conformal fields, employing positron emission tomography/computed tomography (PET/CT) scans to determine the gross tumor volume (GTV). This analysis evaluates the dosimetric results when using selective nodal irradiation (SNI) to treat a patient with L-SCLC, quantitatively comparing the results to standard Intergroup treatment fields. Sixteen consecutive patients with L-SCLC and central mediastinal disease who also underwent pretherapy PET/CT scans were studied in this analysis. For each patient, we created SNI treatment volumes, based on the PET/CT-based criteria for malignancy. We also created 2 ENI plans, the first without heterogeneity corrections, as per the Intergroup 0096 study (ENI(off)) and the second with heterogeneity corrections while maintaining constant the number of MUs delivered between these latter 2 plans (ENI(on)). Nodal stations were contoured using published guidelines, then placed into 4 "bins" (treated nodes, 1 echelon away, >1 echelon away within the mediastinum, contralateral hilar/supraclavicular). These were aggregated across the patients in the study. Dose to these nodal bins and to tumor/normal structures were compared among these plans using pairwise t-tests. The ENI(on) plans demonstrated a statistically significant degradation in dose coverage compared with the ENI(off) plans. ENI and SNI both created a dose gradient to the lymph nodes across the mediastinum. Overall, the gradient was larger for the SNI plans, although the maximum dose to the "1 echelon away" nodes was not statistically different. Coverage of the GTV and planning target volume (PTV) were improved with SNI, while simultaneously reducing esophageal and spinal cord dose though at the expense of modestly reduced dose to anatomically distant lymph nodes

  3. Using lot quality assurance sampling to improve immunization coverage in Bangladesh.

    PubMed Central

    Tawfik, Y.; Hoque, S.; Siddiqi, M.

    2001-01-01

    OBJECTIVE: To determine areas of low vaccination coverage in five cities in Bangladesh (Chittagong, Dhaka, Khulna, Rajshahi, and Syedpur). METHODS: Six studies using lot quality assurance sampling were conducted between 1995 and 1997 by Basic Support for Institutionalizing Child Survival and the Bangladesh National Expanded Programme on Immunization. FINDINGS: BCG vaccination coverage was acceptable in all lots studied; however, the proportion of lots rejected because coverage of measles vaccination was low ranged from 0% of lots in Syedpur to 12% in Chittagong and 20% in Dhaka's zones 7 and 8. The proportion of lots rejected because an inadequate number of children in the sample had been fully vaccinated varied from 11% in Syedpur to 30% in Dhaka. Additionally, analysis of aggregated, weighted immunization coverage showed that there was a high BCG vaccination coverage (the first administered vaccine) and a low measles vaccination coverage (the last administered vaccine) indicating a high drop-out rate, ranging from 14% in Syedpur to 36% in Dhaka's zone 8. CONCLUSION: In Bangladesh, where resources are limited, results from surveys using lot quality assurance sampling enabled managers of the National Expanded Programme on Immunization to identify areas with poor vaccination coverage. Those areas were targeted to receive focused interventions to improve coverage. Since this sampling method requires only a small sample size and was easy for staff to use, it is feasible for routine monitoring of vaccination coverage. PMID:11436470

  4. Targeting MRS-Defined Dominant Intraprostatic Lesions with Inverse-Planned High Dose Rate Brachytherapy. Addendum

    DTIC Science & Technology

    2009-06-01

    imagining) into the HDR brachytherapy treatment planning has been demonstrated. Using the inverse planning program IPSA , dose escalation of target...Principles and Clinical Applications of IPSA ; Nucletron International Physics Seminar, Vaals, Netherlands, Sept 13-16, 2006. 7 IPSA ...experience with IPSA for prostate cancer treatment in HDR Brachytherapy, 4ième séminaire francophone de curiethérapie, Arcachon, France, June 15, 2006

  5. Development and Validation of a Novel Vancomycin Dosing Nomogram for Achieving High-Target Trough Levels at 2 Canadian Teaching Hospitals

    PubMed Central

    Thalakada, Rosanne; Legal, Michael; Lau, Tim T Y; Luey, Tiffany; Batterink, Josh; Ensom, Mary H H

    2012-01-01

    Background: Recent guidelines recommend a vancomycin trough (predose) level between 15 and 20 mg/L in the treatment of invasive gram-positive infections, but most initial dosing nomograms are designed to achieve lower targets (5–15 mg/L). Clinicians need guidance about appropriate initial dosing to achieve the higher target. Objective: To develop and validate a high-target vancomycin dosing nomogram to achieve trough levels of 15–20 mg/L. Methods: A retrospective study was conducted at 2 teaching hospitals, St Paul’s Hospital and Vancouver General Hospital in Vancouver, British Columbia. Patients who were treated with vancomycin between January 2008 and June 2010 and who had achieved a trough level of 14.5–20.5 mg/L were identified. Demographic and clinical data were collected. Multiple linear regression was used to develop a vancomycin dosing nomogram for each hospital site. An integrated nomogram was constructed by merging the data from the 2 hospitals. A unique set of patients at each institution was used for validating their respective nomograms and a pooled group of patients for validating the integrated nomogram. Predictive success was evaluated, and a nomogram was deemed significantly different from another nomogram if p < 0.05 via “χ2 testing. Results: Data from 78 patients at one hospital and 91 patients at the other were used in developing the respective institutional nomograms. For each hospital’s data set, both age and initial serum creatinine were significantly associated with the predicted dosing interval (p < 0.001). Validation in a total of 105 test patients showed that the integrated nomogram had a predictive success rate of 56%. Conclusions: A novel vancomycin dosing nomogram was developed and validated at 2 Canadian teaching hospitals. This integrated nomogram is a tool that clinicians can use in selecting appropriate initial vancomycin regimens on the basis of age and serum creatinine, to achieve high-target levels of 15–20 mg

  6. Visualization of a variety of possible dosimetric outcomes in radiation therapy using dose-volume histogram bands.

    PubMed

    Trofimov, Alexei; Unkelbach, Jan; DeLaney, Thomas F; Bortfeld, Thomas

    2012-01-01

    Dose-volume histograms (DVH) are the most common tool used in the appraisal of the quality of a clinical treatment plan. However, when delivery uncertainties are present, the DVH may not always accurately describe the dose distribution actually delivered to the patient. We present a method, based on DVH formalism, to visualize the variability in the expected dosimetric outcome of a treatment plan. For a case of chordoma of the cervical spine, we compared 2 intensity modulated proton therapy plans. Treatment plan A was optimized based on dosimetric objectives alone (ie, desired target coverage, normal tissue tolerance). Plan B was created employing a published probabilistic optimization method that considered the uncertainties in patient setup and proton range in tissue. Dose distributions and DVH for both plans were calculated for the nominal delivery scenario, as well as for scenarios representing deviations from the nominal setup, and a systematic error in the estimate of range in tissue. The histograms from various scenarios were combined to create DVH bands to illustrate possible deviations from the nominal plan for the expected magnitude of setup and range errors. In the nominal scenario, the DVH from plan A showed superior dose coverage, higher dose homogeneity within the target, and improved sparing of the adjacent critical structure. However, when the dose distributions and DVH from plans A and B were recalculated for different error scenarios (eg, proton range underestimation by 3 mm), the plan quality, reflected by DVH, deteriorated significantly for plan A, while plan B was only minimally affected. In the DVH-band representation, plan A produced wider bands, reflecting its higher vulnerability to delivery errors, and uncertainty in the dosimetric outcome. The results illustrate that comparison of DVH for the nominal scenario alone does not provide any information about the relative sensitivity of dosimetric outcome to delivery uncertainties. Thus, such

  7. Alpha-v Integrin Targeted PET Imaging of Breast Cancer Angiogenesis and Low-Dose Metronomic Anti-Angiogenic Chemotherapy Efficacy

    DTIC Science & Technology

    2008-08-01

    AD_________________ Award Number: W81XWH-04-1-0697 TITLE: Alpha -v Integrin Targeted PET Imaging of...SUBTITLE 5a. CONTRACT NUMBER Alpha -v Integrin Targeted PET Imaging of Breast Cancer Angiogenesis and Low- Dose Metronomic Anti-Angiogenic...Evaluation of biodistribution and anti-tumor effect of a dimeric RGD peptide-paclitaxel conjugate in mice with breast cancer” was published in Eur J Nucl

  8. TH-E-BRE-09: TrueBeam Monte Carlo Absolute Dose Calculations Using Monitor Chamber Backscatter Simulations and Linac-Logged Target Current

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A, Popescu I; Lobo, J; Sawkey, D

    2014-06-15

    Purpose: To simulate and measure radiation backscattered into the monitor chamber of a TrueBeam linac; establish a rigorous framework for absolute dose calculations for TrueBeam Monte Carlo (MC) simulations through a novel approach, taking into account the backscattered radiation and the actual machine output during beam delivery; improve agreement between measured and simulated relative output factors. Methods: The ‘monitor backscatter factor’ is an essential ingredient of a well-established MC absolute dose formalism (the MC equivalent of the TG-51 protocol). This quantity was determined for the 6 MV, 6X FFF, and 10X FFF beams by two independent Methods: (1) MC simulationsmore » in the monitor chamber of the TrueBeam linac; (2) linac-generated beam record data for target current, logged for each beam delivery. Upper head MC simulations used a freelyavailable manufacturer-provided interface to a cloud-based platform, allowing use of the same head model as that used to generate the publicly-available TrueBeam phase spaces, without revealing the upper head design. The MC absolute dose formalism was expanded to allow direct use of target current data. Results: The relation between backscatter, number of electrons incident on the target for one monitor unit, and MC absolute dose was analyzed for open fields, as well as a jaw-tracking VMAT plan. The agreement between the two methods was better than 0.15%. It was demonstrated that the agreement between measured and simulated relative output factors improves across all field sizes when backscatter is taken into account. Conclusion: For the first time, simulated monitor chamber dose and measured target current for an actual TrueBeam linac were incorporated in the MC absolute dose formalism. In conjunction with the use of MC inputs generated from post-delivery trajectory-log files, the present method allows accurate MC dose calculations, without resorting to any of the simplifying assumptions previously made in the

  9. Coverage Gains After the Affordable Care Act Among the Uninsured in Minnesota

    PubMed Central

    Lukanen, Elizabeth; Spencer, Donna; Alarcón, Giovann; Kemmick Pintor, Jessie; Baines Simon, Alisha; Gildemeister, Stefan

    2015-01-01

    Objectives. We determined whether and how Minnesotans who were uninsured in 2013 gained health insurance coverage in 2014, 1 year after the Affordable Care Act (ACA) expanded Medicaid coverage and enrollment. Methods. Insurance status and enrollment experiences came from the Minnesota Health Insurance Transitions Study (MH-HITS), a follow-up telephone survey of children and adults in Minnesota who had no health insurance in the fall of 2013. Results. ACA had a tempered success in Minnesota. Outreach and enrollment efforts were effective; one half of those previously uninsured gained coverage, although many reported difficulty signing up (nearly 62%). Of the previously uninsured who gained coverage, 44% obtained their coverage through MNsure, Minnesota’s insurance marketplace. Most of those who remained uninsured heard of MNsure and went to the Web site. Many still struggled with the enrollment process or reported being deterred by the cost of coverage. Conclusions. Targeting outreach, simplifying the enrollment process, focusing on affordability, and continuing funding for in-person assistance will be important in the future. PMID:26447912

  10. Financial incentives to encourage healthy behaviour: an analysis of U.K. media coverage.

    PubMed

    Parke, Hannah; Ashcroft, Richard; Brown, Rebecca; Marteau, Theresa M; Seale, Clive

    2013-09-01

    Policies to use financial incentives to encourage healthy behaviour are controversial. Much of this controversy is played out in the mass media, both reflecting and shaping public opinion. To describe U.K. mass media coverage of incentive schemes, comparing schemes targeted at different client groups and assessing the relative prominence of the views of different interest groups. Thematic content analysis. National and local news coverage in newspapers, news media targeted at health-care providers and popular websites between January 2005 and February 2010. U.K. mass media. The study included 210 articles. Fifteen separate arguments favourable towards schemes, and 19 unfavourable, were identified. Overall, coverage was more favourable than unfavourable, although most articles reported a mix of views. Arguments about the prevalence and seriousness of the health problems targeted by incentive schemes were uncontested. Moral and ethical objections to such schemes were common, focused in particular on recipients such as drug users or the overweight who were already stereotyped as morally deficient, and these arguments were largely uncontested. Arguments about the effectiveness of schemes and their potential for benefit or harm were areas of greater contestation. Government, public health and other health-care provider interests dominated favourable coverage; opposition came from rival politicians, taxpayers' representatives, certain charities and from some journalists themselves. Those promoting incentive schemes for people who might be regarded as 'undeserving' should plan a media strategy that anticipates their public reception. © 2011 John Wiley & Sons Ltd.

  11. Health-system reform and universal health coverage in Latin America.

    PubMed

    Atun, Rifat; de Andrade, Luiz Odorico Monteiro; Almeida, Gisele; Cotlear, Daniel; Dmytraczenko, T; Frenz, Patricia; Garcia, Patrícia; Gómez-Dantés, Octavio; Knaul, Felicia M; Muntaner, Carles; de Paula, Juliana Braga; Rígoli, Felix; Serrate, Pastor Castell-Florit; Wagstaff, Adam

    2015-03-28

    Starting in the late 1980s, many Latin American countries began social sector reforms to alleviate poverty, reduce socioeconomic inequalities, improve health outcomes, and provide financial risk protection. In particular, starting in the 1990s, reforms aimed at strengthening health systems to reduce inequalities in health access and outcomes focused on expansion of universal health coverage, especially for poor citizens. In Latin America, health-system reforms have produced a distinct approach to universal health coverage, underpinned by the principles of equity, solidarity, and collective action to overcome social inequalities. In most of the countries studied, government financing enabled the introduction of supply-side interventions to expand insurance coverage for uninsured citizens--with defined and enlarged benefits packages--and to scale up delivery of health services. Countries such as Brazil and Cuba introduced tax-financed universal health systems. These changes were combined with demand-side interventions aimed at alleviating poverty (targeting many social determinants of health) and improving access of the most disadvantaged populations. Hence, the distinguishing features of health-system strengthening for universal health coverage and lessons from the Latin American experience are relevant for countries advancing universal health coverage. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Dosimetric comparison of photon and proton treatment techniques for chondrosarcoma of thoracic spine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yadav, Poonam, E-mail: yadav@humonc.wisc.edu; Department of Medical Physics, University of Wisconsin, Madison, WI; University of Wisconsin Riverview Cancer Center, Wisconsin Rapids, WI

    2013-10-01

    Chondrosarcomas are relatively radiotherapy resistant, and also delivering high radiation doses is not feasible owing to anatomic constraints. In this study, the feasibility of helical tomotherapy for treatment of chondrosarcoma of thoracic spine is explored and compared with other available photon and proton radiotherapy techniques in the clinical setting. A patient was treated for high-grade chondrosarcoma of the thoracic spine using tomotherapy. Retrospectively, the tomotherapy plan was compared with intensity-modulated radiation therapy, dynamic arc photon therapy, and proton therapy. Two primary comparisons were made: (1) comparison of normal tissue sparing with comparable target volume coverage (plan-1), and (2) comparison ofmore » target volume coverage with a constrained maximum dose to the cord center (plan-2). With constrained target volume coverage, proton plans were found to yield lower mean doses for all organs at risk (spinal cord, esophagus, heart, and both lungs). Tomotherapy planning resulted in the lowest mean dose to all organs at risk amongst photon-based methods. For cord dose constrained plans, the static-field intensity-modulated radiation therapy and dynamic arc plans resulted target underdosing in 20% and 12% of planning target volume2 volumes, respectively, whereas both proton and tomotherapy plans provided clinically acceptable target volume coverage with no portion of planning target volume2 receiving less than 90% of the prescribed dose. Tomotherapy plans are comparable to proton plans and produce superior results compared with other photon modalities. This feasibility study suggests that tomotherapy is an attractive alternative to proton radiotherapy for delivering high doses to lesions in the thoracic spine.« less

  13. Seeking consensus on universal health coverage indicators in the sustainable development goals.

    PubMed

    Reddock, Jennifer

    2017-01-01

    There is optimism that the inclusion of universal health coverage in the Sustainable Development Goals advances its prominence in global and national health policy. However, formulating indicators for Target 3.8 through the Inter-Agency Expert Group on Sustainable Development Indicators has been challenging. Achieving consensus on the conceptual and methodological aspects of universal health coverage is likely to take some time in multi-stakeholder fora compared with national efforts to select indicators.

  14. Treatment Optimization Using Computed Tomography-Delineated Targets Should be Used for Supraclavicular Irradiation for Breast Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liengsawangwong, Raweewan; Yu, T.-K.; Sun, T.-L.

    2007-11-01

    Background: The purpose of this study was to determine whether the use of optimized CT treatment planning offered better coverage of axillary level III (LIII)/supraclavicular (SC) targets than the empirically derived dose prescription that are commonly used. Materials/Methods: Thirty-two consecutive breast cancer patients who underwent CT treatment planning of a SC field were evaluated. Each patient was categorized according to body mass index (BMI) classes: normal, overweight, or obese. The SC and LIII nodal beds were contoured, and four treatment plans for each patient were generated. Three of the plans used empiric dose prescriptions, and these were compared with amore » CT-optimized plan. Each plan was evaluated by two criteria: whether 98% of target volume receive >90% of prescribed dose and whether < 5% of the irradiated volume received 105% of prescribed dose. Results: The mean depth of SC and LIII were 3.2 cm (range, 1.4-6.7 cm) and 3.1 (range, 1.7-5.8 cm). The depth of these targets varied according across BMI classes (p = 0.01). Among the four sets of plans, the CT-optimized plans were the most successful at achieving both of the dosimetry objectives for every BMI class (normal BMI, p = .003; overweight BMI, p < .0001; obese BMI, p < .001). Conclusions: Across all BMI classes, routine radiation prescriptions did not optimally cover intended targets for every patient. Optimized CT-based treatment planning generated the most successful plans; therefore, we recommend the use of routine CT simulation and treatment planning of SC fields in breast cancer.« less

  15. Methods used for immunization coverage assessment in Canada, a Canadian Immunization Research Network (CIRN) study.

    PubMed

    Wilson, Sarah E; Quach, Susan; MacDonald, Shannon E; Naus, Monika; Deeks, Shelley L; Crowcroft, Natasha S; Mahmud, Salaheddin M; Tran, Dat; Kwong, Jeff; Tu, Karen; Gilbert, Nicolas L; Johnson, Caitlin; Desai, Shalini

    2017-08-03

    Accurate and complete immunization data are necessary to assess vaccine coverage, safety and effectiveness. Across Canada, different methods and data sources are used to assess vaccine coverage, but these have not been systematically described. Our primary objective was to examine and describe the methods used to determine immunization coverage in Canada. The secondary objective was to compare routine infant and childhood coverage estimates derived from the Canadian 2013 Childhood National Immunization Coverage Survey (cNICS) with estimates collected from provinces and territories (P/Ts). We collected information from key informants regarding their provincial, territorial or federal methods for assessing immunization coverage. We also collected P/T coverage estimates for select antigens and birth cohorts to determine absolute differences between these and estimates from cNICS. Twenty-six individuals across 16 public health organizations participated between April and August 2015. Coverage surveys are conducted regularly for toddlers in Quebec and in one health authority in British Columbia. Across P/Ts, different methodologies for measuring coverage are used (e.g., valid doses, grace periods). Most P/Ts, except Ontario, measure up-to-date (UTD) coverage and 4 P/Ts also assess on-time coverage. The degree of concordance between P/T and cNICS coverage estimates varied by jurisdiction, antigen and age group. In addition to differences in the data sources and processes used for coverage assessment, there are also differences between Canadian P/Ts in the methods used for calculating immunization coverage. Comparisons between P/T and cNICS estimates leave remaining questions about the proportion of children fully vaccinated in Canada.

  16. SU-E-T-230: Creating a Large Number of Focused Beams with Variable Patient Head Tilt to Improve Dose Fall-Off for Brain Radiosurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chiu, J; Ma, L

    2015-06-15

    Purpose: To develop a treatment delivery and planning strategy by increasing the number of beams to minimize dose to brain tissue surrounding a target, while maximizing dose coverage to the target. Methods: We analyzed 14 different treatment plans via Leksell PFX and 4C. For standardization, single tumor cases were chosen. Original treatment plans were compared with two optimized plans. The number of beams was increased in treatment plans by varying tilt angles of the patient head, while maintaining original isocenter and the beam positions in the x-, y- and z-axes, collimator size, and beam blocking. PFX optimized plans increased beammore » numbers with three pre-set tilt angles, 70, 90, 110, and 4C optimized plans increased beam numbers with tilt angles increasing arbitrarily from range of 30 to 150 degrees. Optimized treatment plans were compared dosimetrically with original treatment plans. Results: Comparing total normal tissue isodose volumes between original and optimized plans, the low-level percentage isodose volumes decreased in all plans. Despite the addition of multiple beams up to a factor of 25, beam-on times for 1 tilt angle versus 3 or more tilt angles were comparable (<1 min.). In 64% (9/14) of the studied cases, the volume percentage decrease by >5%, with the highest value reaching 19%. The addition of more tilt angles correlates to a greater decrease in normal brain irradiated volume. Selectivity and coverage for original and optimized plans remained comparable. Conclusion: Adding large number of additional focused beams with variable patient head tilt shows improvement for dose fall-off for brain radiosurgery. The study demonstrates technical feasibility of adding beams to decrease target volume.« less

  17. Comparison of different treatment planning optimization methods for vaginal HDR brachytherapy with multichannel applicators: A reduction of the high doses to the vaginal mucosa is possible.

    PubMed

    Carrara, Mauro; Cusumano, Davide; Giandini, Tommaso; Tenconi, Chiara; Mazzarella, Ester; Grisotto, Simone; Massari, Eleonora; Mazzeo, Davide; Cerrotta, Annamaria; Pappalardi, Brigida; Fallai, Carlo; Pignoli, Emanuele

    2017-12-01

    A direct planning approach with multi-channel vaginal cylinders (MVCs) used for HDR brachytherapy of vaginal cancers is particularly challenging. Purpose of this study was to compare the dosimetric performances of different forward and inverse methods used for the optimization of MVC-based vaginal treatments for endometrial cancer, with a particular attention to the definition of strategies useful to limit the high doses to the vaginal mucosa. Twelve postoperative vaginal HDR brachytherapy treatments performed with MVCs were considered. Plans were retrospectively optimized with three different methods: Dose Point Optimization followed by Graphical Optimization (DPO + GrO), Inverse Planning Simulated Annealing with two different class solutions as starting conditions (surflPSA and homogIPSA) and Hybrid Inverse Planning Optimization (HIPO). Several dosimetric parameters related to target coverage, hot spot extensions and sparing of organs at risk were analyzed to evaluate the quality of the achieved treatment plans. Dose homogeneity index (DHI), conformal index (COIN) and a further parameter quantifying the proportion of the central catheter loading with respect to the overall loading (i.e., the central catheter loading index: CCLI) were also quantified. The achieved PTV coverage parameters were highly correlated with each other but uncorrelated with the hot spot quantifiers. HomogIPSA and HIPO achieved higher DHIs and CCLIs and lower volumes of high doses than DPO + GrO and surflPSA. Within the investigated optimization methods, HIPO and homoglPSA showed the highest dose homogeneity to the target. In particular, homogIPSA resulted also the most effective in reducing hot spots to the vaginal mucosa. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  18. Potential dosimetric benefits of adaptive tumor tracking over the internal target volume concept for stereotactic body radiation therapy of pancreatic cancer.

    PubMed

    Karava, Konstantina; Ehrbar, Stefanie; Riesterer, Oliver; Roesch, Johannes; Glatz, Stefan; Klöck, Stephan; Guckenberger, Matthias; Tanadini-Lang, Stephanie

    2017-11-09

    Radiotherapy for pancreatic cancer has two major challenges: (I) the tumor is adjacent to several critical organs and, (II) the mobility of both, the tumor and its surrounding organs at risk (OARs). A treatment planning study simulating stereotactic body radiation therapy (SBRT) for pancreatic tumors with both the internal target volume (ITV) concept and the tumor tracking approach was performed. The two respiratory motion-management techniques were compared in terms of doses to the target volume and organs at risk. Two volumetric-modulated arc therapy (VMAT) treatment plans (5 × 5 Gy) were created for each of the 12 previously treated pancreatic cancer patients, one using the ITV concept and one the tumor tracking approach. To better evaluate the overall dose delivered to the moving tumor volume, 4D dose calculations were performed on four-dimensional computed tomography (4DCT) scans. The resulting planning target volume (PTV) size for each technique was analyzed. Target and OAR dose parameters were reported and analyzed for both 3D and 4D dose calculation. Tumor motion ranged from 1.3 to 11.2 mm. Tracking led to a reduction of PTV size (max. 39.2%) accompanied with significant better tumor coverage (p<0.05, paired Wilcoxon signed rank test) both in 3D and 4D dose calculations and improved organ at risk sparing. Especially for duodenum, stomach and liver, the mean dose was significantly reduced (p<0.05) with tracking for 3D and 4D dose calculations. By using an adaptive tumor tracking approach for respiratory-induced pancreatic motion management, a significant reduction in PTV size can be achieved, which subsequently facilitates treatment planning, and improves organ dose sparing. The dosimetric benefit of tumor tracking is organ and patient-specific.

  19. SU-E-J-179: Prediction of Pelvic Nodal Coverage Using Mutual Information Between Cone-Beam and Planning CTs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jani, S; Kishan, A; O'Connell, D

    2014-06-01

    Purpose: To investigate if pelvic nodal coverage for prostate patients undergoing intensity modulated radiotherapy (IMRT) can be predicted using mutual image information computed between planning and cone-beam CTs (CBCTs). Methods: Four patients with high-risk prostate adenocarcinoma were treated with IMRT on a Varian TrueBeam. Plans were designed such that 95% of the nodal planning target volume (PTV) received the prescription dose of 45 Gy (N=1) or 50.4 Gy (N=3). Weekly CBCTs (N=25) were acquired and the nodal clinical target volumes and organs at risk were contoured by a physician. The percent nodal volume receiving prescription dose was recorded as amore » ground truth. Using the recorded shifts performed by the radiation therapists at the time of image acquisition, CBCTs were aligned with the planning kVCT. Mutual image information (MI) was calculated between the CBCT and the aligned planning CT within the contour of the nodal PTV. Due to variable CBCT fields-of-view, CBCT images covering less than 90% of the nodal volume were excluded from the analysis, resulting in the removal of eight CBCTs. Results: A correlation coefficient of 0.40 was observed between the MI metric and the percent of the nodal target volume receiving the prescription dose. One patient's CBCTs had clear outliers from the rest of the patients. Upon further investigation, we discovered image artifacts that were present only in that patient's images. When those four images were excluded, the correlation improved to 0.81. Conclusion: This pilot study shows the potential of predicting pelvic nodal dosimetry by computing the mutual image information between planning CTs and patient setup CBCTs. Importantly, this technique does not involve manual or automatic contouring of the CBCT images. Additional patients and more robust exclusion criteria will help validate our findings.« less

  20. 4D dose simulation in volumetric arc therapy: Accuracy and affecting parameters

    PubMed Central

    Werner, René

    2017-01-01

    between 98% and 100%. Parameters of major influence on 4D VMAT dose simulation accuracy were the degree of temporal discretization of the dose delivery process (the higher, the better) and correct alignment of the assumed breathing phases at the beginning of the dose measurements and simulations. Given the high γ-passing rates between simulated motion-affected doses and dynamic measurements, we consider the simulations to provide a reliable basis for assessment of VMAT motion effects that–in the sense of 4D QA of VMAT treatment plans–allows to verify target coverage in hypofractioned VMAT-based radiotherapy of moving targets. Remaining differences between measurements and simulations motivate, however, further detailed studies. PMID:28231337

  1. 4D dose simulation in volumetric arc therapy: Accuracy and affecting parameters.

    PubMed

    Sothmann, Thilo; Gauer, Tobias; Werner, René

    2017-01-01

    between 98% and 100%. Parameters of major influence on 4D VMAT dose simulation accuracy were the degree of temporal discretization of the dose delivery process (the higher, the better) and correct alignment of the assumed breathing phases at the beginning of the dose measurements and simulations. Given the high γ-passing rates between simulated motion-affected doses and dynamic measurements, we consider the simulations to provide a reliable basis for assessment of VMAT motion effects that-in the sense of 4D QA of VMAT treatment plans-allows to verify target coverage in hypofractioned VMAT-based radiotherapy of moving targets. Remaining differences between measurements and simulations motivate, however, further detailed studies.

  2. Exploring the relationship between population density and maternal health coverage.

    PubMed

    Hanlon, Michael; Burstein, Roy; Masters, Samuel H; Zhang, Raymond

    2012-11-21

    Delivering health services to dense populations is more practical than to dispersed populations, other factors constant. This engenders the hypothesis that population density positively affects coverage rates of health services. This hypothesis has been tested indirectly for some services at a local level, but not at a national level. We use cross-sectional data to conduct cross-country, OLS regressions at the national level to estimate the relationship between population density and maternal health coverage. We separately estimate the effect of two measures of density on three population-level coverage rates (6 tests in total). Our coverage indicators are the fraction of the maternal population completing four antenatal care visits and the utilization rates of both skilled birth attendants and in-facility delivery. The first density metric we use is the percentage of a population living in an urban area. The second metric, which we denote as a density score, is a relative ranking of countries by population density. The score's calculation discounts a nation's uninhabited territory under the assumption those areas are irrelevant to service delivery. We find significantly positive relationships between our maternal health indicators and density measures. On average, a one-unit increase in our density score is equivalent to a 0.2% increase in coverage rates. Countries with dispersed populations face higher burdens to achieve multinational coverage targets such as the United Nations' Millennial Development Goals.

  3. TH-CD-202-12: Online Inter-Beam Replanning Based On Real-Time Dose Reconstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kamerling, CP; Fast, MF; Ziegenhein, P

    Purpose: This work provides a proof-of-concept study for online replanning during treatment delivery for step-and-shoot prostate SBRT, based on real-time dose reconstruction. Online replanning is expected to improve the trade-off between target coverage and organ-at-risk dose in the presence of intra-fractional motion. Methods: We have implemented an online replanning workflow on top of our previously reported real-time dose reconstruction software which connects to an Elekta research linac. The treatment planning system DynaPlan was extended to (1) re-optimize and sequence treatment plans (in clockwise beam order) before each beam, based on actual delivered dose, in a timeframe limited by the gantrymore » rotation between subsequent beams, and (2) send the respective segments to the delivery control software DynaTrack which starts/continues treatment immediately.To investigate the impact of a reduced safety margin, we have created and delivered (on a linac emulator) a conventional CTV+5/3mm (I) and a reduced CTV+1mm margin (II) treatment plan for a prostate patient. We have assessed CTV coverage with and without inter-beam replanning, all exposed to a gradual target shift of 0–5mm in posterior and inferior direction from start until the end of delivery. Results: For the reconstructed conventional plan (I), D98 for CTV was 100% of D98 of the planned dose. For the reconstructed margin-reduced plan (II), D98 for CTV was 95% of the planned D98 without replanning, but could be recovered to 99% by replanning for each beam. Plan (II) with replanning resulted in a decrease for bladder V90% by 88% and an increase to rectum V90% by 9% compared to the conventional plan (I). Dose calculation/accumulation was performed in <15ms per MLC aperture, replanning in <15s per beam. Conclusion: We have shown that online inter-beam replanning is technically feasible and potentially allows for a margin reduction. Future investigation considering motion-robust replanning optimization

  4. Increasing Coverage of Appropriate Vaccinations

    PubMed Central

    Jacob, Verughese; Chattopadhyay, Sajal K.; Hopkins, David P.; Morgan, Jennifer Murphy; Pitan, Adesola A.; Clymer, John

    2016-01-01

    Context Population-level coverage for immunization against many vaccine-preventable diseases remains below optimal rates in the U.S. The Community Preventive Services Task Force recently recommended several interventions to increase vaccination coverage based on systematic reviews of the evaluation literature. The present study provides the economic results from those reviews. Evidence acquisition A systematic review was conducted (search period, January 1980 through February 2012) to identify economic evaluations of 12 interventions recommended by the Task Force. Evidence was drawn from included studies; estimates were constructed for the population reach of each strategy, cost of implementation, and cost per additional vaccinated person because of the intervention. Analyses were conducted in 2014. Evidence synthesis Reminder systems, whether for clients or providers, were among the lowest-cost strategies to implement and the most cost effective in terms of additional people vaccinated. Strategies involving home visits and combination strategies in community settings were both costly and less cost effective. Strategies based in settings such as schools and managed care organizations that reached the target population achieved additional vaccinations in the middle range of cost effectiveness. Conclusions The interventions recommended by the Task Force differed in reach, cost, and cost effectiveness. This systematic review presents the economic information for 12 effective strategies to increase vaccination coverage that can guide implementers in their choice of interventions to fit their local needs, available resources, and budget. PMID:26847663

  5. Vaccination coverage among social and healthcare workers in ten countries of Samu-social international sites.

    PubMed

    Marshall, Esaie; Salmon, Dominique; Bousfiha, Nadia; Togola, Yacouba; Ouedraogo, François; Santantonio, Maud; Dieng, Coumba Khadidja; Tartière, Suzanne; Emmanuelli, Xavier

    2017-09-18

    We aim to determine the vaccination coverage of social and healthcare workers in International sites of Samusocial, providing emergency care to homeless people, and to assess factors associated with having received necessary doses at adulthood. Data on immunization coverage of social and healthcare workers were provided by a cross-sectional survey, conducted from February to April 2015 among 252 Samusocial workers in 10 countries. Vaccination status and characteristics of participants were collected through a self-administered questionnaire. Prevalence rate ratio (PRR) of vaccination status was calculated using Poisson regression models. Among 252 Samusocial social and health workers who felt a questionnaire, median age was 39years, 42.1% were female, 88.9% were in contact with homeless beneficiaries (19.1% health workers). Overall, 90.1% of Samusocial staff felt adult vaccinations was useful and 70.2% wished to receive booster doses in future. Vaccination coverage at adulthood was satisfactory for diphtheria and poliomyelitis (96%), but low for influenza (20.8%), meningococcus (50.5%), hepatitis B (56.3%), yellow fever (58.1%), measles (81.3%) and pertussis (90.7%). The main reasons for not having received vaccination booster doses were forgetting the dates of booster doses (38.4%) and not having received the information (13.5%). In adjusted analysis, prevalence of up-to-date for vaccination schedule was 35% higher among health workers than among social workers (aPRR=1.35, 95%CI: 1.01-1.82, P=0.05) and was 56% higher among workers who had a documentary evidence of vaccination than in those who did not (aPRR=1.56, 95%CI: 1.19-2.02, P=0.001). The Samusocial International workers vaccine coverage at adulthood was insufficient and disparate by region. It is necessary to strengthen the outreach of this staff and increase immunization policy for hepatitis B, diphtheria, tetanus, and measles, as well as for yellow fever, rabies and meningococcal ACYW135 vaccines in at

  6. Nanoparticle enabled transdermal drug delivery systems for enhanced dose control and tissue targeting

    PubMed Central

    Palmer, Brian C.; DeLouise, Lisa A.

    2017-01-01

    Transdermal drug delivery systems have been around for decades, and current technologies (e.g. patches, ointments, and creams) enhance the skin permeation of low molecular weight, lipophilic drugs that are efficacious at low doses. The objective of current transdermal drug delivery research is to discover ways to enhance skin penetration of larger, hydrophilic drugs and macromolecules for disease treatment and vaccination. Nanocarriers made of lipids, metals, or polymers have been successfully used to increase penetration of drugs or vaccines, control drug release, and target drugs to specific areas of skin in vivo. While more research is needed to identify the safety of nanocarriers, this technology has the potential to expand the use of transdermal routes of administration to a wide array of therapeutics. Here, we review the current state of nanoparticle skin delivery systems with special emphasis on targeting skin diseases. PMID:27983701

  7. Nanoparticle-Enabled Transdermal Drug Delivery Systems for Enhanced Dose Control and Tissue Targeting.

    PubMed

    Palmer, Brian C; DeLouise, Lisa A

    2016-12-15

    Transdermal drug delivery systems have been around for decades, and current technologies (e.g., patches, ointments, and creams) enhance the skin permeation of low molecular weight, lipophilic drugs that are efficacious at low doses. The objective of current transdermal drug delivery research is to discover ways to enhance skin penetration of larger, hydrophilic drugs and macromolecules for disease treatment and vaccination. Nanocarriers made of lipids, metals, or polymers have been successfully used to increase penetration of drugs or vaccines, control drug release, and target drugs to specific areas of skin in vivo. While more research is needed to identify the safety of nanocarriers, this technology has the potential to expand the use of transdermal routes of administration to a wide array of therapeutics. Here, we review the current state of nanoparticle skin delivery systems with special emphasis on targeting skin diseases.

  8. Achieving high coverage in Rwanda's national human papillomavirus vaccination programme.

    PubMed

    Binagwaho, Agnes; Wagner, Claire M; Gatera, Maurice; Karema, Corine; Nutt, Cameron T; Ngabo, Fidele

    2012-08-01

    Virtually all women who have cervical cancer are infected with the human papillomavirus (HPV). Of the 275,000 women who die from cervical cancer every year, 88% live in developing countries. Two vaccines against the HPV have been approved. However, vaccine implementation in low-income countries tends to lag behind implementation in high-income countries by 15 to 20 years. In 2011, Rwanda's Ministry of Health partnered with Merck to offer the Gardasil HPV vaccine to all girls of appropriate age. The Ministry formed a "public-private community partnership" to ensure effective and equitable delivery. Thanks to a strong national focus on health systems strengthening, more than 90% of all Rwandan infants aged 12-23 months receive all basic immunizations recommended by the World Health Organization. In 2011, Rwanda's HPV vaccination programme achieved 93.23% coverage after the first three-dose course of vaccination among girls in grade six. This was made possible through school-based vaccination and community involvement in identifying girls absent from or not enrolled in school. A nationwide sensitization campaign preceded delivery of the first dose. Through a series of innovative partnerships, Rwanda reduced the historical two-decade gap in vaccine introduction between high- and low-income countries to just five years. High coverage rates were achieved due to a delivery strategy that built on Rwanda's strong vaccination system and human resources framework. Following the GAVI Alliance's decision to begin financing HPV vaccination, Rwanda's example should motivate other countries to explore universal HPV vaccine coverage, although implementation must be tailored to the local context.

  9. Influence of eye size and beam entry angle on dose to non-targeted tissues of the eye during stereotactic x-ray radiosurgery of AMD

    NASA Astrophysics Data System (ADS)

    Cantley, Justin L.; Hanlon, Justin; Chell, Erik; Lee, Choonsik; Smith, W. Clay; Bolch, Wesley E.

    2013-10-01

    Age-related macular degeneration is a leading cause of vision loss for the elderly population of industrialized nations. The IRay® Radiotherapy System, developed by Oraya® Therapeutics, Inc., is a stereotactic low-voltage irradiation system designed to treat the wet form of the disease. The IRay System uses three robotically positioned 100 kVp collimated photon beams to deliver an absorbed dose of up to 24 Gy to the macula. The present study uses the Monte Carlo radiation transport code MCNPX to assess absorbed dose to six non-targeted tissues within the eye—total lens, radiosensitive tissues of the lens, optic nerve, distal tip of the central retinal artery, non-targeted portion of the retina, and the ciliary body--all as a function of eye size and beam entry angle. The ocular axial length was ranged from 20 to 28 mm in 2 mm increments, with the polar entry angle of the delivery system varied from 18° to 34° in 2° increments. The resulting data showed insignificant variations in dose for all eye sizes. Slight variations in the dose to the optic nerve and the distal tip of the central retinal artery were noted as the polar beam angle changed. An increase in non-targeted retinal dose was noted as the entry angle increased, while the dose to the lens, sensitive volume of the lens, and ciliary body decreased as the treatment polar angle increased. Polar angles of 26° or greater resulted in no portion of the sensitive volume of the lens receiving an absorbed dose of 0.5 Gy or greater. All doses to non-targeted structures reported in this study were less than accepted thresholds for post-procedure complications.

  10. [Potential coverage and real coverage of ambulatory health care services in the state of Mexico. The case of 3 marginal communities in Atenco and Chalco].

    PubMed

    Nájera-Aguilar, P; Infante-Castañeda, C

    1990-01-01

    Less than a third of the non-insured population studied through a sample in the State of Mexico was covered by the Institute of Health of the State of México. This low coverage was observed in spite the fact that health services were available within 2 kilometer radius. 33 per cent of the non-insured preferred to utilize other services within their own community, and 24 per cent of them traveled to bigger localities to receive care. These results suggest that to attain adequate coverage, utilization patterns should be investigated so that health services can meet the needs of the target population.

  11. Methods used for immunization coverage assessment in Canada, a Canadian Immunization Research Network (CIRN) study

    PubMed Central

    Quach, Susan; MacDonald, Shannon E.; Naus, Monika; Deeks, Shelley L.; Crowcroft, Natasha S.; Mahmud, Salaheddin M.; Tran, Dat; Kwong, Jeff; Tu, Karen; Johnson, Caitlin; Desai, Shalini

    2017-01-01

    ABSTRACT Accurate and complete immunization data are necessary to assess vaccine coverage, safety and effectiveness. Across Canada, different methods and data sources are used to assess vaccine coverage, but these have not been systematically described. Our primary objective was to examine and describe the methods used to determine immunization coverage in Canada. The secondary objective was to compare routine infant and childhood coverage estimates derived from the Canadian 2013 Childhood National Immunization Coverage Survey (cNICS) with estimates collected from provinces and territories (P/Ts). We collected information from key informants regarding their provincial, territorial or federal methods for assessing immunization coverage. We also collected P/T coverage estimates for select antigens and birth cohorts to determine absolute differences between these and estimates from cNICS. Twenty-six individuals across 16 public health organizations participated between April and August 2015. Coverage surveys are conducted regularly for toddlers in Quebec and in one health authority in British Columbia. Across P/Ts, different methodologies for measuring coverage are used (e.g., valid doses, grace periods). Most P/Ts, except Ontario, measure up-to-date (UTD) coverage and 4 P/Ts also assess on-time coverage. The degree of concordance between P/T and cNICS coverage estimates varied by jurisdiction, antigen and age group. In addition to differences in the data sources and processes used for coverage assessment, there are also differences between Canadian P/Ts in the methods used for calculating immunization coverage. Comparisons between P/T and cNICS estimates leave remaining questions about the proportion of children fully vaccinated in Canada. PMID:28708945

  12. Role of renal function in risk assessment of target non-attainment after standard dosing of meropenem in critically ill patients: a prospective observational study.

    PubMed

    Ehmann, Lisa; Zoller, Michael; Minichmayr, Iris K; Scharf, Christina; Maier, Barbara; Schmitt, Maximilian V; Hartung, Niklas; Huisinga, Wilhelm; Vogeser, Michael; Frey, Lorenz; Zander, Johannes; Kloft, Charlotte

    2017-10-21

    Severe bacterial infections remain a major challenge in intensive care units because of their high prevalence and mortality. Adequate antibiotic exposure has been associated with clinical success in critically ill patients. The objective of this study was to investigate the target attainment of standard meropenem dosing in a heterogeneous critically ill population, to quantify the impact of the full renal function spectrum on meropenem exposure and target attainment, and ultimately to translate the findings into a tool for practical application. A prospective observational single-centre study was performed with critically ill patients with severe infections receiving standard dosing of meropenem. Serial blood samples were drawn over 4 study days to determine meropenem serum concentrations. Renal function was assessed by creatinine clearance according to the Cockcroft and Gault equation (CLCR CG ). Variability in meropenem serum concentrations was quantified at the middle and end of each monitored dosing interval. The attainment of two pharmacokinetic/pharmacodynamic targets (100%T >MIC , 50%T >4×MIC ) was evaluated for minimum inhibitory concentration (MIC) values of 2 mg/L and 8 mg/L and standard meropenem dosing (1000 mg, 30-minute infusion, every 8 h). Furthermore, we assessed the impact of CLCR CG on meropenem concentrations and target attainment and developed a tool for risk assessment of target non-attainment. Large inter- and intra-patient variability in meropenem concentrations was observed in the critically ill population (n = 48). Attainment of the target 100%T >MIC was merely 48.4% and 20.6%, given MIC values of 2 mg/L and 8 mg/L, respectively, and similar for the target 50%T >4×MIC . A hyperbolic relationship between CLCR CG (25-255 ml/minute) and meropenem serum concentrations at the end of the dosing interval (C 8h ) was derived. For infections with pathogens of MIC 2 mg/L, mild renal impairment up to augmented renal function was

  13. Coverage with Evidence Development: applications and issues.

    PubMed

    Trueman, Paul; Grainger, David L; Downs, Kristen E

    2010-01-01

    The aim of this study was to describe the current issues surrounding Coverage with Evidence Development (CED). CED is characterized by restricted coverage for a new technology in parallel with targeted research when the stated goal of the research or data collection is to provide definitive evidence for the clinical or cost-effectiveness impact of the new technology. Presented here is information summarized and interpreted from presentations and discussions at the 2008 Health Technology Assessment International (HTAi) meeting and additional information from the medical literature. This study describes the differences between CED and other conditional coverage agreements, provides a brief history of CED, describes real-world examples of CED, describes the areas of consensus between the stakeholders, discusses the areas for future negotiation between stakeholders, and proposes criteria to assist stakeholders in determining when CED could be appropriate. Payers could interpret the evidence obtained from a CED program either positively or negatively, and a range of possible changes to the reimbursement status of the new technology may result. Striking an appropriate balance between the demands for prompt access to new technology and acknowledging that some degree of uncertainty will always exist is a critical challenge to the uptake of this innovative form of conditional coverage. When used selectively for innovative procedures, pharmaceuticals, or devices in the appropriate disease areas, CED may provide patients access to promising medicines or technologies while data to minimize uncertainty are collected.

  14. DNA barcoding in the media: does coverage of cool science reflect its social context?

    PubMed

    Geary, Janis; Camicioli, Emma; Bubela, Tania

    2016-09-01

    Paul Hebert and colleagues first described DNA barcoding in 2003, which led to international efforts to promote and coordinate its use. Since its inception, DNA barcoding has generated considerable media coverage. We analysed whether this coverage reflected both the scientific and social mandates of international barcoding organizations. We searched newspaper databases to identify 900 English-language articles from 2003 to 2013. Coverage of the science of DNA barcoding was highly positive but lacked context for key topics. Coverage omissions pose challenges for public understanding of the science and applications of DNA barcoding; these included coverage of governance structures and issues related to the sharing of genetic resources across national borders. Our analysis provided insight into how barcoding communication efforts have translated into media coverage; more targeted communication efforts may focus media attention on previously omitted, but important topics. Our analysis is timely as the DNA barcoding community works to establish the International Society for the Barcode of Life.

  15. Calculation and Prediction of the Effect of Respiratory Motion on Whole Breast Radiation Therapy Dose Distributions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cao Junsheng; Roeske, John C.; Chmura, Steve J.

    2009-07-01

    The standard treatment technique used for whole-breast irradiation can result in undesirable dose distributions in the treatment site, leading to skin reaction/fibrosis and pulmonary and cardiac toxicities. Hence, the technique has evolved from conventional wedged technique (CWT) to segment intensity-modulated radiation therapy (SIMRT) and beamlet IMRT (IMRT). However, these newer techniques feature more highly modulated dose distributions that may be affected by respiration. The purpose of this work was to conduct a simple study of the clinical impact of respiratory motion on breast radiotherapy dose distributions for the three treatment planning techniques. The ultimate goal was to determine which patientsmore » would benefit most from the use of motion management. Eight patients with early-stage breast cancer underwent a free-breathing (FB) computed tomography (CT) simulation, with medial and lateral markers placed on the skin. Two additional CT scans were obtained at the end of inspiration (EI) and the end of expiration (EE). The FB-CT scan was used to develop treatment plans using each technique. Each plan was then applied to EI and EE-CT scans. Compared with the FB CT scan, the medial markers moved up to 1.8 cm in the anterior-superior direction at the end of inspiration (EI-scan), and on average 8 mm. The CWT and SIMRT techniques were not 'sensitive' to respiratory motion, because the % clinical target volume (CTV) receiving 95% of the prescription dose (V{sub 95%}) remained constant for both techniques. For patients that had large respiratory motion indicated by marker movement >0.6 cm, differences in coverage of the CTV at the V100% between FB and EI for beamlet IMRT plans were on the order of >10% and up to 18%. A linear model was developed to relate the dosimetric coverage difference introduced by respiration with the motion information. With this model, the dosimetric coverage difference introduced by respiratory motion could be evaluated during

  16. RuBisCO depletion improved proteome coverage of cold responsive S-nitrosylated targets in Brassica juncea

    PubMed Central

    Sehrawat, Ankita; Abat, Jasmeet K.; Deswal, Renu

    2013-01-01

    Although in the last few years good number of S-nitrosylated proteins are identified but information on endogenous targets is still limiting. Therefore, an attempt is made to decipher NO signaling in cold treated Brassica juncea seedlings. Treatment of seedlings with substrate, cofactor and inhibitor of Nitric-oxide synthase and nitrate reductase (NR), indicated NR mediated NO biosynthesis in cold. Analysis of the in vivo thiols showed depletion of low molecular weight thiols and enhancement of available protein thiols, suggesting redox changes. To have a detailed view, S-nitrosylation analysis was done using biotin switch technique (BST) and avidin-affinity chromatography. Ribulose-1,5-bisphosphate carboxylase/oxygenase (RuBisCO) is S-nitrosylated and therefore, is identified as target repeatedly due to its abundance. It also competes out low abundant proteins which are important NO signaling components. Therefore, RuBisCO was removed (over 80%) using immunoaffinity purification. Purified S-nitrosylated RuBisCO depleted proteins were resolved on 2-D gel as 110 spots, including 13 new, which were absent in the crude S-nitrosoproteome. These were identified by nLC-MS/MS as thioredoxin, fructose biphosphate aldolase class I, myrosinase, salt responsive proteins, peptidyl-prolyl cis-trans isomerase and malate dehydrogenase. Cold showed differential S-nitrosylation of 15 spots, enhanced superoxide dismutase activity (via S-nitrosylation) and promoted the detoxification of superoxide radicals. Increased S-nitrosylation of glyceraldehyde-3-phosphate dehydrogenase sedoheptulose-biphosphatase, and fructose biphosphate aldolase, indicated regulation of Calvin cycle by S-nitrosylation. The results showed that RuBisCO depletion improved proteome coverage and provided clues for NO signaling in cold. PMID:24032038

  17. Towards new methods for the determination of dose limiting toxicities and the assessment of the recommended dose for further studies of molecularly targeted agents--dose-Limiting Toxicity and Toxicity Assessment Recommendation Group for Early Trials of Targeted therapies, an European Organisation for Research and Treatment of Cancer-led study.

    PubMed

    Postel-Vinay, Sophie; Collette, Laurence; Paoletti, Xavier; Rizzo, Elisa; Massard, Christophe; Olmos, David; Fowst, Camilla; Levy, Bernard; Mancini, Pierre; Lacombe, Denis; Ivy, Percy; Seymour, Lesley; Le Tourneau, Christophe; Siu, Lillian L; Kaye, Stan B; Verweij, Jaap; Soria, Jean-Charles

    2014-08-01

    Traditional dose-limiting toxicity (DLT) definition, which uses grade (G) 3-4 toxicity data from cycle 1 (C1) only, may not be appropriate for molecularly targeted agents (MTAs) of prolonged administration, for which late or lower grade toxicities also deserve attention. In collaboration with pharmaceutical companies and academia, an European Organisation for Research and Treatment of Cancer (EORTC)-led initiative, Dose-Limiting Toxicity and Toxicity Assessment Recommendation Group for Early Trials of Targeted therapies (DLT-TARGETT), collected data from completed phase 1 trials evaluating MTAs as monotherapy. All toxicities at least possibly related to the study drugs that occurred during C1-6, their type, grade (CTCAEv3.0), and duration as well as patients' relative dose-intensity (RDI), were recorded. The 54 eligible trials enrolled 2084 evaluable adult patients with solid tumours between 1999 and 2013, and evaluated small molecules (40), antibodies (seven), recombinant peptides (five) and antisense oligodeoxynucleotides (two). A maximum tolerated dose was set in 43 trials. Fifteen percent of the patients received <75% of the intended RDI in C1, but only 9.1% of them presented protocol-defined DLTs. After C1, 16-19% of patients received <75% of the intended RDI. A similar proportion of G ⩾ 3 toxicities was recorded in C1 and after C1 (936 and 1087 toxicities, respectively), with the first G⩾3 toxicity occurring after C1 in 18.6% of patients. Although protocol-defined DLT period is traditionally limited to C1, almost 20% of patients present significant reductions in RDI at any time in phase 1 trials of MTAs. Recommended phase 2 dose assessment should incorporate all available information from any cycle (notably lower grade toxicities leading to such RDI decrease), and be based on achieving >75% RDI. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Cross-National Differences in Special Education Coverage: An Empirical Analysis

    ERIC Educational Resources Information Center

    Anastasiou, Dimitris; Keller, Clayton E.

    2014-01-01

    This study investigated the role of educational and socioeconomic factors in explaining differences in national special education coverage. Data were derived from several international and governmental sources, targeting the year 2008 and covering 143 countries. Descriptive statistics revealed huge disparities in access to special education among…

  19. Policy Choices for Progressive Realization of Universal Health Coverage

    PubMed Central

    Tangcharoensathien, Viroj; Patcharanarumol, Walaiporn; Panichkriangkrai, Warisa; Sommanustweechai, Angkana

    2017-01-01

    In responses to Norheim’s editorial, this commentary offers reflections from Thailand, how the five unacceptable trade-offs were applied to the universal health coverage (UHC) reforms between 1975 and 2002 when the whole 64 million people were covered by one of the three public health insurance systems. This commentary aims to generate global discussions on how best UHC can be gradually achieved. Not only the proposed five discrete trade-offs within each dimension, there are also trade-offs between the three dimensions of UHC such as population coverage, service coverage and cost coverage. Findings from Thai UHC show that equity is applied for the population coverage extension, when the low income households and the informal sector were the priority population groups for coverage extension by different prepayment schemes in 1975 and 1984, respectively. With an exception of public sector employees who were historically covered as part of fringe benefits were covered well before the poor. The private sector employees were covered last in 1990. Historically, Thailand applied a comprehensive benefit package where a few items are excluded using the negative list; until there was improved capacities on technology assessment that cost-effectiveness are used for the inclusion of new interventions into the benefit package. Not only cost-effectiveness, but long term budget impact, equity and ethical considerations are taken into account. Cost coverage is mostly determined by the fiscal capacities. Close ended budget with mix of provider payment methods are used as a tool for trade-off service coverage and financial risk protection. Introducing copayment in the context of fee-for-service can be harmful to beneficiaries due to supplier induced demands, inefficiency and unpredictable out of pocket payment by households. UHC achieves favorable outcomes as it was implemented when there was a full geographical coverage of primary healthcare coverage in all districts and sub

  20. Is Colombia reaching the goals on infant immunization coverage? A quantitative survey from 80 municipalities.

    PubMed

    Narváez, Javier; Osorio, May Bibiana; Castañeda-Orjuela, Carlos; Alvis Zakzuk, Nelson; Cediel, Natalia; Chocontá-Piraquive, Luz Ángela; de La Hoz-Restrepo, Fernando

    2017-03-13

    This study aimed to evaluate the coverage of the Colombian Expanded Program on Immunization among children less than 6years old, to evaluate the timeliness of immunization, to assess the coverage of newly introduced vaccines, and to identify factors associated with lack of immunization. We conducted a cross-sectional survey in 80 municipalities of Colombia, using a two-stage cluster random sampling. We attempted to contact all children less than 6years old living in the sampled blocks, and asked their caregivers to provide immunization record cards. We also collected basic sociodemographic information. We reached 81% of the attempted household contacts, identifying 18,232 children; of them, 14,805 (83%) had an immunization record card. Coverage for traditional vaccines was above 90%: BCG (tuberculosis) 95.7% (95%CI: 95.1-96.4), pentavalent vaccine 93.3% (92.4-94.3), MMR (measles, mumps, rubella) initial dose 94.5% (93.5-95.6); but it was lower for recently introduced vaccines: rotavirus 80% (77.8-82.1), influenza 48.4% (45.9-50.8). Results for timely vaccination were not equally successful: pentavalent vaccine 44.2% (41.4-47.1), MMR initial dose 71.2% (68.9-73.4). Mother's education was significantly associated with higher immunization odds. Older age, a greater number of siblings, low socioeconomic status, and not having health insurance were significantly associated with lower immunization odds. There was significant heterogeneity in immunization rates by municipality across the country. Although absolute immunization coverage for traditional vaccines met the goal of 90% for the 80 municipalities combined, disparities in coverage across municipalities, delayed immunization, and decline of coverage with age, are common problems in Colombia that may result in reduced protection. Newly introduced vaccines require additional efforts to reach the goal. These results highlight the association of health inequities with low immunization coverage and delayed immunization

  1. Multi-Agent Cooperative Target Search

    PubMed Central

    Hu, Jinwen; Xie, Lihua; Xu, Jun; Xu, Zhao

    2014-01-01

    This paper addresses a vision-based cooperative search for multiple mobile ground targets by a group of unmanned aerial vehicles (UAVs) with limited sensing and communication capabilities. The airborne camera on each UAV has a limited field of view and its target discriminability varies as a function of altitude. First, by dividing the whole surveillance region into cells, a probability map can be formed for each UAV indicating the probability of target existence within each cell. Then, we propose a distributed probability map updating model which includes the fusion of measurement information, information sharing among neighboring agents, information decay and transmission due to environmental changes such as the target movement. Furthermore, we formulate the target search problem as a multi-agent cooperative coverage control problem by optimizing the collective coverage area and the detection performance. The proposed map updating model and the cooperative control scheme are distributed, i.e., assuming that each agent only communicates with its neighbors within its communication range. Finally, the effectiveness of the proposed algorithms is illustrated by simulation. PMID:24865884

  2. Constellation Coverage Analysis

    NASA Technical Reports Server (NTRS)

    Lo, Martin W. (Compiler)

    1997-01-01

    The design of satellite constellations requires an understanding of the dynamic global coverage provided by the constellations. Even for a small constellation with a simple circular orbit propagator, the combinatorial nature of the analysis frequently renders the problem intractable. Particularly for the initial design phase where the orbital parameters are still fluid and undetermined, the coverage information is crucial to evaluate the performance of the constellation design. We have developed a fast and simple algorithm for determining the global constellation coverage dynamically using image processing techniques. This approach provides a fast, powerful and simple method for the analysis of global constellation coverage.

  3. Hepatitis B vaccination coverage among adults aged ≥18 years traveling to a country of high or intermediate endemicity, United States, 2015.

    PubMed

    Lu, Peng-Jun; O'Halloran, Alissa C; Williams, Walter W; Nelson, Noele P

    2018-04-28

    Persons from the United States who travel to developing countries are at substantial risk for hepatitis B virus (HBV) infection. Hepatitis B vaccine has been recommended for adults at increased risk for infection, including travelers to high or intermediate hepatitis B endemic countries. To assess hepatitis B vaccination coverage among adults ≥18 years traveling to a country of high or intermediate endemicity from the United States. Data from the 2015 National Health Interview Survey (NHIS) were analyzed to determine hepatitis B vaccination coverage (≥1 dose) and series completion (≥3 doses) among persons aged ≥18 years who reported traveling to a country of high or intermediate hepatitis B endemicity. Multivariable logistic regression and predictive marginal analyses were conducted to identify factors independently associated with hepatitis B vaccination. In 2015, hepatitis B vaccination coverage (≥1 dose) among adults aged ≥18 years who reported traveling to high or intermediate hepatitis B endemic countries was 38.6%, significantly higher compared with 25.9% among non-travelers. Series completion (≥3 doses) was 31.7% and 21.2%, respectively (P < 0.05). On multivariable analysis among all respondents, travel status was significantly associated with hepatitis B vaccination coverage and series completion. Other characteristics independently associated with vaccination (≥1 dose, and ≥3 doses) among travelers included age, race/ethnicity, educational level, duration of US residence, number of physician contacts in the past year, status of ever being tested for HIV, and healthcare personnel status. Although travel to a country of high or intermediate hepatitis B endemicity was associated with higher likelihood of hepatitis B vaccination, hepatitis B vaccination coverage was low among adult travelers to these areas. Healthcare providers should ask their patients about travel plans and recommend and offer travel related vaccinations to their

  4. Electron intensity modulation for mixed-beam radiation therapy with an x-ray multi-leaf collimator

    NASA Astrophysics Data System (ADS)

    Weinberg, Rebecca

    The current standard treatment for head and neck cancer at our institution uses intensity-modulated x-ray therapy (IMRT), which improves target coverage and sparing of critical structures by delivering complex fluence patterns from a variety of beam directions to conform dose distributions to the shape of the target volume. The standard treatment for breast patients is field-in-field forward-planned IMRT, with initial tangential fields and additional reduced-weight tangents with blocking to minimize hot spots. For these treatment sites, the addition of electrons has the potential of improving target coverage and sparing of critical structures due to rapid dose falloff with depth and reduced exit dose. In this work, the use of mixed-beam therapy (MBT), i.e., combined intensity-modulated electron and x-ray beams using the x-ray multi-leaf collimator (MLC), was explored. The hypothesis of this study was that addition of intensity-modulated electron beams to existing clinical IMRT plans would produce MBT plans that were superior to the original IMRT plans for at least 50% of selected head and neck and 50% of breast cases. Dose calculations for electron beams collimated by the MLC were performed with Monte Carlo methods. An automation system was created to facilitate communication between the dose calculation engine and the treatment planning system. Energy and intensity modulation of the electron beams was accomplished by dividing the electron beams into 2x2-cm2 beamlets, which were then beam-weight optimized along with intensity-modulated x-ray beams. Treatment plans were optimized to obtain equivalent target dose coverage, and then compared with the original treatment plans. MBT treatment plans were evaluated by participating physicians with respect to target coverage, normal structure dose, and overall plan quality in comparison with original clinical plans. The physician evaluations did not support the hypothesis for either site, with MBT selected as superior in 1

  5. Vancomycin Dosing in Obese Patients: Special Considerations and Novel Dosing Strategies.

    PubMed

    Durand, Cheryl; Bylo, Mary; Howard, Brian; Belliveau, Paul

    2018-06-01

    To review the literature regarding vancomycin pharmacokinetics in obese patients and strategies used to improve dosing in this population. PubMed, EMBASE (1974 to November 2017), and Google Scholar searches were conducted using the search terms vancomycin, obese, obesity, pharmacokinetics, strategy, and dosing. Additional articles were selected from reference lists of selected studies. Included articles were those published in English with a primary focus on vancomycin pharmacokinetic parameters in obese patients and practical vancomycin dosing strategies, clinical experiences, or challenges of dosing vancomycin in this population. Volume of distribution and clearance are the pharmacokinetic parameters that most often affect vancomycin dosing in obese patients; both are increased in this population. Challenges with dosing in obese patients include inconsistent and inadequate dosing, observations that the obese population may not be homogeneous, and reports of an increased likelihood of supratherapeutic trough concentrations. Investigators have revised and developed dosing and monitoring protocols to address these challenges. These approaches improved target trough attainment to varying degrees. Some of the vancomycin dosing approaches provided promising results in obese patients, but there were notable differences in methods used to develop these approaches, and sample sizes were small. Although some approaches can be considered for validation in individual institutions, further research is warranted. This may include validating approaches in larger populations with narrower obesity severity ranges, investigating target attainment in indication-specific target ranges, and evaluating the impact of different dosing weights and methods of creatinine clearance calculation.

  6. Exploring the relationship between population density and maternal health coverage

    PubMed Central

    2012-01-01

    Background Delivering health services to dense populations is more practical than to dispersed populations, other factors constant. This engenders the hypothesis that population density positively affects coverage rates of health services. This hypothesis has been tested indirectly for some services at a local level, but not at a national level. Methods We use cross-sectional data to conduct cross-country, OLS regressions at the national level to estimate the relationship between population density and maternal health coverage. We separately estimate the effect of two measures of density on three population-level coverage rates (6 tests in total). Our coverage indicators are the fraction of the maternal population completing four antenatal care visits and the utilization rates of both skilled birth attendants and in-facility delivery. The first density metric we use is the percentage of a population living in an urban area. The second metric, which we denote as a density score, is a relative ranking of countries by population density. The score’s calculation discounts a nation’s uninhabited territory under the assumption those areas are irrelevant to service delivery. Results We find significantly positive relationships between our maternal health indicators and density measures. On average, a one-unit increase in our density score is equivalent to a 0.2% increase in coverage rates. Conclusions Countries with dispersed populations face higher burdens to achieve multinational coverage targets such as the United Nations’ Millennial Development Goals. PMID:23170895

  7. Coverage of neonatal screening: failure of coverage or failure of information system

    PubMed Central

    Ades, A; Walker, J; Jones, R; Smith, I

    2001-01-01

    OBJECTIVES—To evaluate neonatal screening coverage using data routinely collected on the laboratory computer.
SUBJECTS—90 850 births in 14 North East Thames community provider districts over a 21 month period.
METHODS—Births notified to local child health computers are electronically copied to the neonatal laboratory computer system, and incoming Guthrie cards are matched against these birth records before testing. The computer records for the study period were processed to estimate the coverage of the screening programme.
RESULTS—Out of an estimated 90 850 births notified to child health computers, all but 746 (0.82%) appeared to have been screened or could be otherwise accounted for (0.14% in non-metropolitan districts, 0.39% in suburban districts, and 1.68% in inner city districts). A further 893 resident infants had been tested, but could not be matched to the list of notified resident births. The calculated programme coverage already exceeds the 99.5% National Audit Programme standard in 7/14 districts. Elsewhere it is not clear whether it is coverage or recording of coverage that is low.
CONCLUSION—Previous reports of low coverage may have been exaggerated. High coverage can be shown using routine information systems. Design of information systems that deliver accurate measures of coverage would be more useful than comparison of inadequately measured coverage with a national standard. The new NHS number project will create an opportunity to achieve this.
 PMID:11369561

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Yao; Chen, Josephine; Leary, Celeste I.

    Radiation of the low neck can be accomplished using split-field intensity-modulated radiation therapy (sf-IMRT) or extended-field intensity-modulated radiation therapy (ef-IMRT). We evaluated the effect of these treatment choices on target coverage and thyroid and larynx doses. Using data from 14 patients with cancers of the oropharynx, we compared the following 3 strategies for radiating the low neck: (1) extended-field IMRT, (2) traditional split-field IMRT with an initial cord-junction block to 40 Gy, followed by a full-cord block to 50 Gy, and (3) split-field IMRT with a full-cord block to 50 Gy. Patients were planned using each of these 3 techniques.more » To facilitate comparison, extended-field plans were normalized to deliver 50 Gy to 95% of the neck volume. Target coverage was assessed using the dose to 95% of the neck volume (D{sub 95}). Mean thyroid and larynx doses were computed. Extended-field IMRT was used as the reference arm; the mean larynx dose was 25.7 ± 7.4 Gy, and the mean thyroid dose was 28.6 ± 2.4 Gy. Split-field IMRT with 2-step blocking reduced laryngeal dose (mean larynx dose 15.2 ± 5.1 Gy) at the cost of a moderate reduction in target coverage (D{sub 95} 41.4 ± 14 Gy) and much higher thyroid dose (mean thyroid dose 44.7 ± 3.7 Gy). Split-field IMRT with initial full-cord block resulted in greater laryngeal sparing (mean larynx dose 14.2 ± 5.1 Gy) and only a moderately higher thyroid dose (mean thyroid dose 31 ± 8 Gy) but resulted in a significant reduction in target coverage (D{sub 95} 34.4 ± 15 Gy). Extended-field IMRT comprehensively covers the low neck and achieves acceptable thyroid and laryngeal sparing. Split-field IMRT with a full-cord block reduces laryngeal doses to less than 20 Gy and spares the thyroid, at the cost of substantially reduced coverage of the low neck. Traditional 2-step split-field IMRT similarly reduces the laryngeal dose but also reduces low-neck coverage and delivers very high doses to the thyroid.« less

  9. Low-Dose Irradiation Enhances Gene Targeting in Human Pluripotent Stem Cells.

    PubMed

    Hatada, Seigo; Subramanian, Aparna; Mandefro, Berhan; Ren, Songyang; Kim, Ho Won; Tang, Jie; Funari, Vincent; Baloh, Robert H; Sareen, Dhruv; Arumugaswami, Vaithilingaraja; Svendsen, Clive N

    2015-09-01

    Human pluripotent stem cells (hPSCs) are now being used for both disease modeling and cell therapy; however, efficient homologous recombination (HR) is often crucial to develop isogenic control or reporter lines. We showed that limited low-dose irradiation (LDI) using either γ-ray or x-ray exposure (0.4 Gy) significantly enhanced HR frequency, possibly through induction of DNA repair/recombination machinery including ataxia-telangiectasia mutated, histone H2A.X and RAD51 proteins. LDI could also increase HR efficiency by more than 30-fold when combined with the targeting tools zinc finger nucleases, transcription activator-like effector nucleases, and clustered regularly interspaced short palindromic repeats. Whole-exome sequencing confirmed that the LDI administered to hPSCs did not induce gross genomic alterations or affect cellular viability. Irradiated and targeted lines were karyotypically normal and made all differentiated lineages that continued to express green fluorescent protein targeted at the AAVS1 locus. This simple method allows higher throughput of new, targeted hPSC lines that are crucial to expand the use of disease modeling and to develop novel avenues of cell therapy. The simple and relevant technique described in this report uses a low level of radiation to increase desired gene modifications in human pluripotent stem cells by an order of magnitude. This higher efficiency permits greater throughput with reduced time and cost. The low level of radiation also greatly increased the recombination frequency when combined with developed engineered nucleases. Critically, the radiation did not lead to increases in DNA mutations or to reductions in overall cellular viability. This novel technique enables not only the rapid production of disease models using human stem cells but also the possibility of treating genetically based diseases by correcting patient-derived cells. ©AlphaMed Press.

  10. SU-E-T-233: Cyberknife Versus Linac IMRT for Dose Comparision in Hypofractionated Hemi Larynx Irradiation of Early Stage True Vocal Cord Cancer: A Dosimetric Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, C; Lee, P; Jiang, S

    2015-06-15

    Purpose: To compare dosimetric data of patients treated for early-stage larynx cancer on Cyberknife and Linac IMRT. Methods: Nine patients were treated with Cyberknife to a dose of 45 Gy in 10 fractions of the involved hemilarynx. The prescription dose provided at least 95% of PTV coverage. After Cyberknife treatment, the CT images and contours were sent to Pinnacle treatment planning system for IMRT planning on a regular SBRT linac with same dose prescription and constrains. Dose to target and normal tissue, including the arytenoids, cord, carotid arteries, thyroid, and skin, were analyzed using dose volume histograms. Results: For Cyberknifemore » plan, the conformity indices are within 1.11–1.33. The average dose to the contralateral arytenoids for Cyberknife plans was 28.9±6.5Gy), which is lower than the same mean dose for IMRT plans (34.0±5.2 Gy). The average maximum dose to the ipsilateral and contralateral carotid artery were 20.6 ±9.1 Gy and 10.2±6.0 Gy respectively for Cybeknife comparing with 22.1±8.0 Gy and 12.0±5.1 Gy for IMRT. The mean dose to the thyroid was 3.6±2.2 Gy for Cyberknife and 3.4±2.4 Gy for IMRT. As shown in DVH, the Cyberknife can deliver less dose to the normal tissue which is close to target area comparing with IMRT Plans. However, IMRT plan’s can give more sparing for the critical organs which is far away from the target area. Conclusion: We have compared the dosimetric parameters of Cyberknife and linac IMRT plans for patients with early-stage larynx cancer. Both Cyberknife and IMRT plans can achieve conformal dose distribution to the target area. Cyberknife was able to reduce normal tissue dose in high doses region while IMRT plans can reduce the dose of the normal tissue at the low dose region. These dosimetric parameters can be used to guide future prospective protocols using SBRT for larynx cancer.« less

  11. [Impact of a targeted technical assistance to improve vaccine coverage in Cameroon, Côte d'Ivoire, and Mauritania in 2014].

    PubMed

    Ahanhanzo, Y Glèlè; Palenfo, D; Saussier, C; Gbèdonou, P; Tonda, A; Da Silva, A; Aplogan, A

    2016-08-01

    Within the framework of its strategic goal of vaccine coverage (VC) improvement, GAVI, The Vaccine Alliance has entrusted the Agence de médecine préventive (agency for preventive medicine, AMP) with technical assistance services to Cameroon, Cote d'Ivoire (Ivory Coast), and Mauritania. This support was provided to selected priority districts (PDs) with the worst Penta3 coverage performances. In 2014, PDs benefited from technical and management capacities in vaccinology strengthening for district medical officers, supportive supervisions and technical assistance in health logistics, data management and quality. We analyzed the effects of the AMP technical assistance on the improvement of the cumulative Penta3 coverage, which is the key performance indicator of the expanded programme on immunization (EPI) performance. We compared Penta3 coverage between PDs and other non-priority districts (NPDs), Penta3 coverage evolution within each PD, and the distribution of PDs and NPDs according to Penta3 coverage category between January and December 2014. Technical assistance had a positive effect on the EPI performance. Indeed Penta3 coverage progression was higher in PDs than in NPDs throughout the period. Besides, between January and December 2014, the Penta3 VC increased in 70%, 100% and 86% of DPs in Cameroon, Côte d'Ivoire and Mauritania, respectively. Furthermore, the increase in the number of PDs with a Penta3 coverage over 80% was higher in DPs than in NPDs: 20% versus 8% for Cameroon, 58% versus 29% for Côte d'Ivoire and 17% versus 8% for Mauritania. Despite positive and encouraging results, this technical assistance service can be improved and efforts are needed to ensure that all health districts have a VC above 80% for all EPI vaccines. The current challenge is for African countries to mobilize resources for maintaining the knowledge and benefits and scaling such interventions in the public health area.

  12. [Benchmarking of performance of Mexican states with effective coverage].

    PubMed

    Lozano, Rafael; Soliz, Patricia; Gakidou, Emmanuela; Abbott-Klafter, Jesse; Feehan, Dennis M; Vidal, Cecilia; Ortiz, Juan Pablo; Murray, Christopher J L

    2007-01-01

    Benchmarking of the performance of states, provinces, or districts in a decentralised health system is important for fostering of accountability, monitoring of progress, identification of determinants of success and failure, and creation of a culture of evidence. The Mexican Ministry of Health has, since 2001, used a benchmarking approach based on the World Health Organization (WHO) concept of effective coverage of an intervention, which is defined as the proportion of potential health gain that could be delivered by the health system to that which is actually delivered. Using data collection systems, including state representative examination surveys, vital registration, and hospital discharge registries, we have monitored the delivery of 14 interventions for 2005-06. Overall effective coverage ranges from 54.0% in Chiapas, a poor state, to 65.1% in the Federal District. Effective coverage for maternal and child health interventions is substantially higher than that for interventions that target other health problems. Effective coverage for the lowest wealth quintile is 52% compared with 61% for the highest quintile. Effective coverage is closely related to public-health spending per head across states; this relation is stronger for interventions that are not related to maternal and child health than those for maternal and child health. Considerable variation also exists in effective coverage at similar amounts of spending. We discuss the implications of these issues for the further development of the Mexican health-information system. Benchmarking of performance by measuring effective coverage encourages decision-makers to focus on quality service provision, not only service availability. The effective coverage calculation is an important device for health-system stewardship. In adopting this approach, other countries should select interventions to be measured on the basis of the criteria of affordability, effect on population health, effect on health

  13. Benchmarking of performance of Mexican states with effective coverage.

    PubMed

    Lozano, Rafael; Soliz, Patricia; Gakidou, Emmanuela; Abbott-Klafter, Jesse; Feehan, Dennis M; Vidal, Cecilia; Ortiz, Juan Pablo; Murray, Christopher J L

    2006-11-11

    Benchmarking of the performance of states, provinces, or districts in a decentralised health system is important for fostering of accountability, monitoring of progress, identification of determinants of success and failure, and creation of a culture of evidence. The Mexican Ministry of Health has, since 2001, used a benchmarking approach based on the WHO concept of effective coverage of an intervention, which is defined as the proportion of potential health gain that could be delivered by the health system to that which is actually delivered. Using data collection systems, including state representative examination surveys, vital registration, and hospital discharge registries, we have monitored the delivery of 14 interventions for 2005-06. Overall effective coverage ranges from 54.0% in Chiapas, a poor state, to 65.1% in the Federal District. Effective coverage for maternal and child health interventions is substantially higher than that for interventions that target other health problems. Effective coverage for the lowest wealth quintile is 52% compared with 61% for the highest quintile. Effective coverage is closely related to public-health spending per head across states; this relation is stronger for interventions that are not related to maternal and child health than those for maternal and child health. Considerable variation also exists in effective coverage at similar amounts of spending. We discuss the implications of these issues for the further development of the Mexican health-information system. Benchmarking of performance by measuring effective coverage encourages decision-makers to focus on quality service provision, not only service availability. The effective coverage calculation is an important device for health-system stewardship. In adopting this approach, other countries should select interventions to be measured on the basis of the criteria of affordability, effect on population health, effect on health inequalities, and capacity to measure

  14. Evaluation of Mean Glandular Dose and Modulation Transfer Function for Different Tube Potentials and Target-Filter Combinations in Computed Radiography Mammography

    PubMed Central

    Abdul Aziz,, Siti Aishah; Mohd Saparudin, Abdul Khaliq; Harun, Ahmad Zaky

    2013-01-01

    Background: Different target-filter combinations in computed radiography have different impacts on the dose and image quality in digital radiography. This study aims to evaluate the mean glandular dose (MGD) and modulation transfer function (MTF) of various target-filter combinations by investigating the signal intensities of X-ray beams. Methods: General Electric (GE) Senographe DMR Plus mammography unit was used for MGD and MTF evaluation. The measured MGD was compared with the dose reference level (DRL), whereas the MTF was evaluated using ImageJ 1.46o software. A modified Mammography Accreditation Phantom RMI 156 was exposed using different target-filter combinations of molybdenum-molybdenum (Mo-Mo), molybdenum-rhodium (Mo-Rh) and rhodium-rhodium (Rh-Rh) at two different tube voltages, 26 kV and 32 kV with 50 mAs. Results: In the MGD evaluations, all target-filters gave an MGD value of < 1.5 mGy. The one-way ANOVA test showed a highly significant interaction between the MGD and the kilovoltage and target-filter material used (26 kV: F (2,12) = 49,234, P = 0.001;32 kV: F (2,12) = 89,972, P = 0.001). A Tukey post-hoc test revealed that the MGD for 26 kV and 32 kV was highly affected by the target-filter combinations. The test of homogeneity of variances indicates that the MGD varies significantly for 26 kV and 32 kV images (0.045 and 0.030 (P < 0.05), respectively). However, the one-way ANOVA for the MTF shows that no significant difference exists between the target-filter combinations used with 26 kV and 32 kV images either in parallel or perpendicular to the chest wall side F (2,189) = 0.26, P > 0.05). Conclusion: Higher tube voltage and atomic number target-filter yield higher MGD values. However, the MTF is independent of the X-ray energy and the type of target-filter combinations used. PMID:23966821

  15. Fully immunized child: coverage, timing and sequencing of routine immunization in an urban poor settlement in Nairobi, Kenya.

    PubMed

    Mutua, Martin Kavao; Kimani-Murage, Elizabeth; Ngomi, Nicholas; Ravn, Henrik; Mwaniki, Peter; Echoka, Elizabeth

    2016-01-01

    More efforts have been put in place to increase full immunization coverage rates in the last decade. Little is known about the levels and consequences of delaying or vaccinating children in different schedules. Vaccine effectiveness depends on the timing of its administration, and it is not optimal if given early, delayed or not given as recommended. Evidence of non-specific effects of vaccines is well documented and could be linked to timing and sequencing of immunization. This paper documents the levels of coverage, timing and sequencing of routine childhood vaccines. The study was conducted between 2007 and 2014 in two informal urban settlements in Nairobi. A total of 3856 children, aged 12-23 months and having a vaccination card seen were included in analysis. Vaccination dates recorded from the cards seen were used to define full immunization coverage, timeliness and sequencing. Proportions, medians and Kaplan-Meier curves were used to assess and describe the levels of full immunization coverage, vaccination delays and sequencing. The findings indicate that 67 % of the children were fully immunized by 12 months of age. Missing measles and third doses of polio and pentavalent vaccine were the main reason for not being fully immunized. Delays were highest for third doses of polio and pentavalent and measles. About 22 % of fully immunized children had vaccines in an out-of-sequence manner with 18 % not receiving pentavalent together with polio vaccine as recommended. Results show higher levels of missed opportunities and low coverage of routine childhood vaccinations given at later ages. New strategies are needed to enable health care providers and parents/guardians to work together to increase the levels of completion of all required vaccinations. In particular, more focus is needed on vaccines given in multiple doses (polio, pentavalent and pneumococcal conjugate vaccines).

  16. Dosimetric comparison between conventional and conformal radiotherapy for carcinoma cervix: Are we treating the right volumes?

    PubMed Central

    Goswami, Jyotirup; Patra, Niladri B.; Sarkar, Biplab; Basu, Ayan; Pal, Santanu

    2013-01-01

    Background and Purpose: Conventional portals, based on bony anatomy, for external beam radiotherapy for cervical cancer have been repeatedly demonstrated as inadequate. Conversely, with image-based conformal radiotherapy, better target coverage may be offset by the greater toxicities and poorer compliance associated with treating larger volumes. This study was meant to dosimetrically compare conformal and conventional radiotherapy. Materials and Methods: Five patients of carcinoma cervix underwent planning CT scan with IV contrast and targets, and organs at risk (OAR) were contoured. Two sets of plans-conventional and conformal were generated for each patient. Field sizes were recorded, and dose volume histograms of both sets of plans were generated and compared on the basis of target coverage and OAR sparing. Results: Target coverage was significantly improved with conformal plans though field sizes required were significantly larger. On the other hand, dose homogeneity was not significantly improved. Doses to the OARs (rectum, urinary bladder, and small bowel) were not significantly different across the 2 arms. Conclusion: Three-dimensional conformal radiotherapy gives significantly better target coverage, which may translate into better local control and survival. On the other hand, it also requires significantly larger field sizes though doses to the OARs are not significantly increased. PMID:24455584

  17. Increasing influenza vaccination coverage in recommended population groups in Europe.

    PubMed

    Blank, Patricia R; Szucs, Thomas D

    2009-04-01

    The clinical and economic burden of seasonal influenza is frequently underestimated. The cornerstone of controlling and preventing influenza is vaccination. National and international guidelines aim to implement immunization programs and targeted vaccination-coverage rates, which should help to enhance the vaccine uptake, especially in the at-risk population. This review purposes to highlight the vaccination guidelines and the actual vaccination situation in four target groups (the elderly, people with underlying chronic conditions, healthcare workers and children) from a European point of view.

  18. Transport networks and inequities in vaccination: remoteness shapes measles vaccine coverage and prospects for elimination across Africa.

    PubMed

    Metcalf, C J E; Tatem, A; Bjornstad, O N; Lessler, J; O'Reilly, K; Takahashi, S; Cutts, F; Grenfell, B T

    2015-05-01

    Measles vaccination is estimated to have averted 13·8 million deaths between 2000 and 2012. Persisting heterogeneity in coverage is a major contributor to continued measles mortality, and a barrier to measles elimination and introduction of rubella-containing vaccine. Our objective is to identify determinants of inequities in coverage, and how vaccine delivery must change to achieve elimination goals, which is a focus of the WHO Decade of Vaccines. We combined estimates of travel time to the nearest urban centre (⩾50 000 people) with vaccination data from Demographic Health Surveys to assess how remoteness affects coverage in 26 African countries. Building on a statistical mapping of coverage against age and geographical isolation, we quantified how modifying the rate and age range of vaccine delivery affects national coverage. Our scenario analysis considers increasing the rate of delivery of routine vaccination, increasing the target age range of routine vaccination, and enhanced delivery to remote areas. Geographical isolation plays a key role in defining vaccine inequity, with greater inequity in countries with lower measles vaccine coverage. Eliminating geographical inequities alone will not achieve thresholds for herd immunity, indicating that changes in delivery rate or age range of routine vaccination will be required. Measles vaccine coverage remains far below targets for herd immunity in many countries on the African continent and is likely to be inadequate for achieving rubella elimination. The impact of strategies such as increasing the upper age range eligible for routine vaccination should be considered.

  19. Patient-specific dose estimation for pediatric chest CT

    PubMed Central

    Li, Xiang; Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Frush, Donald P.

    2008-01-01

    Current methods for organ and effective dose estimations in pediatric CT are largely patient generic. Physical phantoms and computer models have only been developed for standard/limited patient sizes at discrete ages (e.g., 0, 1, 5, 10, 15years old) and do not reflect the variability of patient anatomy and body habitus within the same size/age group. In this investigation, full-body computer models of seven pediatric patients in the same size/protocol group (weight: 11.9–18.2kg) were created based on the patients’ actual multi-detector array CT (MDCT) data. Organs and structures in the scan coverage were individually segmented. Other organs and structures were created by morphing existing adult models (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. Organ and effective dose of these patients from a chest MDCT scan protocol (64 slice LightSpeed VCT scanner, 120kVp, 70 or 75mA, 0.4s gantry rotation period, pitch of 1.375, 20mm beam collimation, and small body scan field-of-view) was calculated using a Monte Carlo program previously developed and validated to simulate radiation transport in the same CT system. The seven patients had normalized effective dose of 3.7–5.3mSv∕100mAs (coefficient of variation: 10.8%). Normalized lung dose and heart dose were 10.4–12.6mGy∕100mAs and 11.2–13.3mGy∕100mAs, respectively. Organ dose variations across the patients were generally small for large organs in the scan coverage (<7%), but large for small organs in the scan coverage (9%–18%) and for partially or indirectly exposed organs (11%–77%). Normalized effective dose correlated weakly with body weight (correlation coefficient:r=−0.80). Normalized lung dose and heart dose correlated strongly with mid-chest equivalent diameter (lung: r=−0.99, heart: r=−0.93); these strong correlation relationships can be used to estimate patient

  20. Patient-specific dose estimation for pediatric chest CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li Xiang; Samei, Ehsan; Segars, W. Paul

    2008-12-15

    Current methods for organ and effective dose estimations in pediatric CT are largely patient generic. Physical phantoms and computer models have only been developed for standard/limited patient sizes at discrete ages (e.g., 0, 1, 5, 10, 15 years old) and do not reflect the variability of patient anatomy and body habitus within the same size/age group. In this investigation, full-body computer models of seven pediatric patients in the same size/protocol group (weight: 11.9-18.2 kg) were created based on the patients' actual multi-detector array CT (MDCT) data. Organs and structures in the scan coverage were individually segmented. Other organs and structuresmore » were created by morphing existing adult models (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. Organ and effective dose of these patients from a chest MDCT scan protocol (64 slice LightSpeed VCT scanner, 120 kVp, 70 or 75 mA, 0.4 s gantry rotation period, pitch of 1.375, 20 mm beam collimation, and small body scan field-of-view) was calculated using a Monte Carlo program previously developed and validated to simulate radiation transport in the same CT system. The seven patients had normalized effective dose of 3.7-5.3 mSv/100 mAs (coefficient of variation: 10.8%). Normalized lung dose and heart dose were 10.4-12.6 mGy/100 mAs and 11.2-13.3 mGy/100 mAs, respectively. Organ dose variations across the patients were generally small for large organs in the scan coverage (<7%), but large for small organs in the scan coverage (9%-18%) and for partially or indirectly exposed organs (11%-77%). Normalized effective dose correlated weakly with body weight (correlation coefficient: r=-0.80). Normalized lung dose and heart dose correlated strongly with mid-chest equivalent diameter (lung: r=-0.99, heart: r=-0.93); these strong correlation relationships can be used to estimate patient-specific organ

  1. Immunization coverage and predictive factors for complete and age-appropriate vaccination among preschoolers in Athens, Greece: a cross--sectional study.

    PubMed

    Pavlopoulou, Ioanna D; Michail, Koralia A; Samoli, Evangelia; Tsiftis, George; Tsoumakas, Konstantinos

    2013-10-02

    In Greece, several new childhood vaccines were introduced recently but were reimbursed gradually and at different time points. The aim of this study was to assess immunization coverage and identify factors influencing complete and age-appropriate vaccination among children attending public nurseries in the municipal district of Athens. A cross-sectional study, using stratified sampling was performed. Immunization history was obtained from vaccination booklets. Demographic and socioeconomic data were obtained from school registries and telephone interviews. Vaccination rates were estimated by sample weighted proportions while associations between complete and age-appropriate immunization and potential determinants by logistic regression analysis. A total of 731 children (mean age: 46, median: 48, range: 10-65 months) were included. Overall immunization coverage with traditional vaccines (DTP, polio, Hib, HBV, 1st dose MMR) was satisfactory, exceeding 90%, but the administration of booster doses was delayed (range: 33.7- 97.4%, at 60 months of age). Complete vaccination rates were lower for new vaccines (Men C, PCV7, varicella, hepatitis A), ranging between 61-92%. In addition, a significant delay in timely administration of Men C, PCV7, as well as HBV was noted (22.9%, 16.0% and 27.7% at 12 months of age, respectively). Child's age was strongly associated with incomplete vaccination with all vaccines (p< 0.001), while as immigrant status was a predictor of incomplete (p=0.034) and delayed vaccination (p<0.001) with traditional vaccines. Increasing household size and higher maternal education were negatively associated with the receipt of all and newly licensed vaccines, respectively (p=0.035). Our findings highlight the need to monitor uptake of new vaccines and improve age- appropriate administration of booster doses as well as early vaccination against hepatitis B. Immigrant status, increased household size and high maternal education may warrant targeted

  2. Immunization coverage and predictive factors for complete and age-appropriate vaccination among preschoolers in Athens, Greece: a cross- sectional study

    PubMed Central

    2013-01-01

    Background In Greece, several new childhood vaccines were introduced recently but were reimbursed gradually and at different time points. The aim of this study was to assess immunization coverage and identify factors influencing complete and age-appropriate vaccination among children attending public nurseries in the municipal district of Athens. Methods A cross-sectional study, using stratified sampling was performed. Immunization history was obtained from vaccination booklets. Demographic and socioeconomic data were obtained from school registries and telephone interviews. Vaccination rates were estimated by sample weighted proportions while associations between complete and age-appropriate immunization and potential determinants by logistic regression analysis. Results A total of 731 children (mean age: 46, median: 48, range: 10–65 months) were included. Overall immunization coverage with traditional vaccines (DTP, polio, Hib, HBV, 1st dose MMR) was satisfactory, exceeding 90%, but the administration of booster doses was delayed (range: 33.7- 97.4%, at 60 months of age). Complete vaccination rates were lower for new vaccines (Men C, PCV7, varicella, hepatitis A), ranging between 61-92%. In addition, a significant delay in timely administration of Men C, PCV7, as well as HBV was noted (22.9%, 16.0% and 27.7% at 12 months of age, respectively). Child’s age was strongly associated with incomplete vaccination with all vaccines (p< 0.001), while as immigrant status was a predictor of incomplete (p=0.034) and delayed vaccination (p<0.001) with traditional vaccines. Increasing household size and higher maternal education were negatively associated with the receipt of all and newly licensed vaccines, respectively (p=0.035). Conclusions Our findings highlight the need to monitor uptake of new vaccines and improve age- appropriate administration of booster doses as well as early vaccination against hepatitis B. Immigrant status, increased household size and high

  3. Invitation coverage and participation in Italian cervical, breast and colorectal cancer screening programmes.

    PubMed

    Giorgi Rossi, Paolo; Carrozzi, Giuliano; Federici, Antonio; Mancuso, Pamela; Sampaolo, Letizia; Zappa, Marco

    2018-03-01

    Objectives In Italy, regional governments organize cervical, breast and colorectal cancer screening programmes, but there are difficulties in regularly inviting all the target populations and participation remains low. We analysed the determinants associated with invitation coverage of and participation in these programmes. Methods We used data on screening programmes from annual Ministry of Health surveys, 1999-2012 for cervical, 1999-2011 for breast and 2005-2011 for colorectal cancer. For recent years, we linked these data to the results of the national routine survey on preventive behaviours to evaluate the effect of spontaneous screening at Province level. Invitation and participation relative risk were calculated using Generalized Linear Models. Results There is a strong decreasing trend in invitation coverage and participation in screening programmes from North to South Italy. In metropolitan areas, both invitation coverage (rate ratio 0.35-0.96) and participation (rate ratio 0.63-0.88) are lower. An inverse association exists between spontaneous screening and both screening invitation coverage (1-3% decrease in invitation coverage per 1% spontaneous coverage increase) and participation (2% decrease in participation per 1% spontaneous coverage increase) for the three programmes. High recall rate has a negative effect on invitation coverage in the next round for breast cancer (1% decrease in invitation per 1% recall increase). Conclusions Organizational and cultural changes are needed to better implement cancer screening in southern Italy.

  4. Correlates of human papillomavirus vaccine coverage: a state-level analysis.

    PubMed

    Moss, Jennifer L; Reiter, Paul L; Brewer, Noel T

    2015-02-01

    We tested the hypothesis that states with higher rates of cancers associated with human papillomavirus (HPV) would have lower HPV vaccine coverage. We gathered state-level data on HPV-related cancer rates and HPV vaccine initiation coverage for girls and boys, separately, and HPV vaccine follow-through (i.e., receipt of 3 doses among those initiating the series) for girls only. In addition, we gathered state-level data on demographic composition and contact with the health care system. We calculated Pearson correlations for these ecological relationships. Human papillomavirus vaccine initiation among girls was lower in states with higher levels of cervical cancer incidence and mortality (r = -0.29 and -0.46, respectively). In addition, vaccine follow-through among girls was lower in states with higher levels of cervical cancer mortality (r = -0.30). Other cancer rates were associated with HPV vaccine initiation and follow-through among girls, but not among boys. Human papillomavirus vaccine initiation among girls was lower in states with higher proportions of non-Hispanic black residents and lower proportions of higher-income residents. Human papillomavirus vaccine follow-through was higher in states with greater levels of adolescents' contact with the health care system. Human papillomavirus vaccine coverage for girls was lower in states with higher HPV-related cancer rates. Public health efforts should concentrate on geographic areas with higher cancer rates. Strengthening adolescent preventive health care use may be particularly important to increase vaccine follow-through. Cost-effectiveness analyses may overestimate the benefits of current vaccination coverage and underestimate the benefits of increasing coverage.

  5. SU-E-J-240: The Impact On Clinical Dose-Distributions When Using MR-Images Registered with Stereotactic CT-Images in Gamma Knife Radiosurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Benmakhlouf, H; Kraepelien, T; Forander, P

    2014-06-01

    Purpose: Most Gamma knife treatments are based solely on MR-images. However, for fractionated treatments and to implement TPS dose calculations that require electron densities, CT image data is essential. The purpose of this work is to assess the dosimetric effects of using MR-images registered with stereotactic CT-images in Gamma knife treatments. Methods: Twelve patients treated for vestibular schwannoma with Gamma Knife Perfexion (Elekta Instruments, Sweden) were selected for this study. The prescribed doses (12 Gy to periphery) were delivered based on the conventional approach of using stereotactic MR-images only. These plans were imported into stereotactic CT-images (by registering MR-images withmore » stereotactic CT-images using the Leksell gamma plan registration software). The dose plans, for each patient, are identical in both cases except for potential rotations and translations resulting from the registration. The impact of the registrations was assessed by an algorithm written in Matlab. The algorithm compares the dose-distributions voxel-by-voxel between the two plans, calculates the full dose coverage of the target (treated in the conventional approach) achieved by the CT-based plan, and calculates the minimum dose delivered to the target (treated in the conventional approach) achieved by the CT-based plan. Results: The mean dose difference between the plans was 0.2 Gy to 0.4 Gy (max 4.5 Gy) whereas between 89% and 97% of the target (treated in the conventional approach) received the prescribed dose, by the CT-plan. The minimum dose to the target (treated in the conventional approach) given by the CT-based plan was between 7.9 Gy and 10.7 Gy (compared to 12 Gy in the conventional treatment). Conclusion: The impact of using MR-images registered with stereotactic CT-images has successfully been compared to conventionally delivered dose plans showing significant differences between the two. Although CTimages have been implemented clinically; the

  6. Further observations on comparison of immunization coverage by lot quality assurance sampling and 30 cluster sampling.

    PubMed

    Singh, J; Jain, D C; Sharma, R S; Verghese, T

    1996-06-01

    Lot Quality Assurance Sampling (LQAS) and standard EPI methodology (30 cluster sampling) were used to evaluate immunization coverage in a Primary Health Center (PHC) where coverage levels were reported to be more than 85%. Of 27 sub-centers (lots) evaluated by LQAS, only 2 were accepted for child coverage, whereas none was accepted for tetanus toxoid (TT) coverage in mothers. LQAS data were combined to obtain an estimate of coverage in the entire population; 41% (95% CI 36-46) infants were immunized appropriately for their ages, while 42% (95% CI 37-47) of their mothers had received a second/ booster dose of TT. TT coverage in 149 contemporary mothers sampled in EPI survey was also 42% (95% CI 31-52). Although results by the two sampling methods were consistent with each other, a big gap was evident between reported coverage (in children as well as mothers) and survey results. LQAS was found to be operationally feasible, but it cost 40% more and required 2.5 times more time than the EPI survey. LQAS therefore, is not a good substitute for current EPI methodology to evaluate immunization coverage in a large administrative area. However, LQAS has potential as method to monitor health programs on a routine basis in small population sub-units, especially in areas with high and heterogeneously distributed immunization coverage.

  7. Drug Coverage (Part D)

    MedlinePlus

    ... insurance Find health & drug plans Drug coverage (Part D) How to get drug coverage Choose from 2 ... drug coverage. You can choose a Medicare Part D plan. Or, you can choose a Medicare Advantage ...

  8. Role of step size and max dwell time in anatomy based inverse optimization for prostate implants

    PubMed Central

    Manikandan, Arjunan; Sarkar, Biplab; Rajendran, Vivek Thirupathur; King, Paul R.; Sresty, N.V. Madhusudhana; Holla, Ragavendra; Kotur, Sachin; Nadendla, Sujatha

    2013-01-01

    In high dose rate (HDR) brachytherapy, the source dwell times and dwell positions are vital parameters in achieving a desirable implant dose distribution. Inverse treatment planning requires an optimal choice of these parameters to achieve the desired target coverage with the lowest achievable dose to the organs at risk (OAR). This study was designed to evaluate the optimum source step size and maximum source dwell time for prostate brachytherapy implants using an Ir-192 source. In total, one hundred inverse treatment plans were generated for the four patients included in this study. Twenty-five treatment plans were created for each patient by varying the step size and maximum source dwell time during anatomy-based, inverse-planned optimization. Other relevant treatment planning parameters were kept constant, including the dose constraints and source dwell positions. Each plan was evaluated for target coverage, urethral and rectal dose sparing, treatment time, relative target dose homogeneity, and nonuniformity ratio. The plans with 0.5 cm step size were seen to have clinically acceptable tumor coverage, minimal normal structure doses, and minimum treatment time as compared with the other step sizes. The target coverage for this step size is 87% of the prescription dose, while the urethral and maximum rectal doses were 107.3 and 68.7%, respectively. No appreciable difference in plan quality was observed with variation in maximum source dwell time. The step size plays a significant role in plan optimization for prostate implants. Our study supports use of a 0.5 cm step size for prostate implants. PMID:24049323

  9. Hepatitis B vaccination coverage among adults aged ≥ 18 years traveling to a country of high or intermediate endemicity, United States, 2015.

    PubMed

    Lu, Peng-Jun; O'Halloran, Alissa C; Williams, Walter W; Nelson, Noele P

    2018-04-25

    Persons from the United States who travel to developing countries are at substantial risk for hepatitis B virus (HBV) infection. Hepatitis B vaccine has been recommended for adults at increased risk for infection, including travelers to high or intermediate hepatitis B endemic countries. To assess hepatitis B vaccination coverage among adults ≥ 18 years traveling to a country of high or intermediate endemicity from the United States. Data from the 2015 National Health Interview Survey (NHIS) were analyzed to determine hepatitis B vaccination coverage (≥1 dose) and series completion (≥3 doses) among persons aged ≥ 18 years who reported traveling to a country of high or intermediate hepatitis B endemicity. Multivariable logistic regression and predictive marginal analyses were conducted to identify factors independently associated with hepatitis B vaccination. In 2015, hepatitis B vaccination coverage (≥1 dose) among adults aged ≥ 18 years who reported traveling to high or intermediate hepatitis B endemic countries was 38.6%, significantly higher compared with 25.9% among non-travelers. Series completion (≥3 doses) was 31.7% and 21.2%, respectively (P < 0.05). On multivariable analysis among all respondents, travel status was significantly associated with hepatitis B vaccination coverage and series completion. Other characteristics independently associated with vaccination (≥1 dose, and ≥ 3 doses) among travelers included age, race/ethnicity, educational level, duration of U.S. residence, number of physician contacts in the past year, status of ever being tested for HIV, and healthcare personnel status. Although travel to a country of high or intermediate hepatitis B endemicity was associated with higher likelihood of hepatitis B vaccination, hepatitis B vaccination coverage was low among adult travelers to these areas. Healthcare providers should ask their patients about travel plans and recommend and offer travel related

  10. Global estimates of human papillomavirus vaccination coverage by region and income level: a pooled analysis.

    PubMed

    Bruni, Laia; Diaz, Mireia; Barrionuevo-Rosas, Leslie; Herrero, Rolando; Bray, Freddie; Bosch, F Xavier; de Sanjosé, Silvia; Castellsagué, Xavier

    2016-07-01

    Since 2006, many countries have implemented publicly funded human papillomavirus (HPV) immunisation programmes. However, global estimates of the extent and impact of vaccine coverage are still unavailable. We aimed to quantify worldwide cumulative coverage of publicly funded HPV immunisation programmes up to 2014, and the potential impact on future cervical cancer cases and deaths. Between Nov 1 and Dec 22, 2014, we systematically reviewed PubMed, Scopus, and official websites to identify HPV immunisation programmes worldwide, and retrieved age-specific HPV vaccination coverage rates up to October, 2014. To estimate the coverage and number of vaccinated women, retrieved coverage rates were converted into birth-cohort-specific rates, with an imputation algorithm to impute missing data, and applied to global population estimates and cervical cancer projections by country and income level. From June, 2006, to October, 2014, 64 countries nationally, four countries subnationally, and 12 overseas territories had implemented HPV immunisation programmes. An estimated 118 million women had been targeted through these programmes, but only 1% were from low-income or lower-middle-income countries. 47 million women (95% CI 39-55 million) received the full course of vaccine, representing a total population coverage of 1·4% (95% CI 1·1-1·6), and 59 million women (48-71 million) had received at least one dose, representing a total population coverage of 1·7% (1·4-2·1). In more developed regions, 33·6% (95% CI 25·9-41·7) of females aged 10-20 years received the full course of vaccine, compared with only 2·7% (1·8-3·6) of females in less developed regions. The impact of the vaccine will be higher in upper-middle-income countries (178 192 averted cases by age 75 years) than in high-income countries (165 033 averted cases), despite the lower number of vaccinated women (13·3 million vs 32·2 million). Many women from high-income and upper-middle-income countries have

  11. Treatment planning and dose analysis for interstitial photodynamic therapy of prostate cancer

    NASA Astrophysics Data System (ADS)

    Davidson, Sean R. H.; Weersink, Robert A.; Haider, Masoom A.; Gertner, Mark R.; Bogaards, Arjen; Giewercer, David; Scherz, Avigdor; Sherar, Michael D.; Elhilali, Mostafa; Chin, Joseph L.; Trachtenberg, John; Wilson, Brian C.

    2009-04-01

    With the development of new photosensitizers that are activated by light at longer wavelengths, interstitial photodynamic therapy (PDT) is emerging as a feasible alternative for the treatment of larger volumes of tissue. Described here is the application of PDT treatment planning software developed by our group to ensure complete coverage of larger, geometrically complex target volumes such as the prostate. In a phase II clinical trial of TOOKAD vascular targeted photodynamic therapy (VTP) for prostate cancer in patients who failed prior radiotherapy, the software was used to generate patient-specific treatment prescriptions for the number of treatment fibres, their lengths, their positions and the energy each delivered. The core of the software is a finite element solution to the light diffusion equation. Validation against in vivo light measurements indicated that the software could predict the location of an iso-fluence contour to within approximately ±2 mm. The same software was used to reconstruct the treatments that were actually delivered, thereby providing an analysis of the threshold light dose required for TOOKAD-VTP of the post-irradiated prostate. The threshold light dose for VTP-induced prostate damage, as measured one week post-treatment using contrast-enhanced MRI, was found to be highly heterogeneous, both within and between patients. The minimum light dose received by 90% of the prostate, D90, was determined from each patient's dose-volume histogram and compared to six-month sextant biopsy results. No patient with a D90 less than 23 J cm-2 had complete biopsy response, while 8/13 (62%) of patients with a D90 greater than 23 J cm-2 had negative biopsies at six months. The doses received by the urethra and the rectal wall were also investigated.

  12. First Outbreak Response Using an Oral Cholera Vaccine in Africa: Vaccine Coverage, Acceptability and Surveillance of Adverse Events, Guinea, 2012

    PubMed Central

    Luquero, Francisco J.; Grout, Lise; Ciglenecki, Iza; Sakoba, Keita; Traore, Bala; Heile, Melat; Dialo, Alpha Amadou; Itama, Christian; Serafini, Micaela; Legros, Dominique; Grais, Rebecca F.

    2013-01-01

    Background Despite World Health Organization (WHO) prequalification of two safe and effective oral cholera vaccines (OCV), concerns about the acceptability, potential diversion of resources, cost and feasibility of implementing timely campaigns has discouraged their use. In 2012, the Ministry of Health of Guinea, with the support of Médecins Sans Frontières organized the first mass vaccination campaign using a two-dose OCV (Shanchol) as an additional control measure to respond to the on-going nationwide epidemic. Overall, 316,250 vaccines were delivered. Here, we present the results of vaccination coverage, acceptability and surveillance of adverse events. Methodology/Principal Findings We performed a cross-sectional cluster survey and implemented adverse event surveillance. The study population included individuals older than 12 months, eligible for vaccination, and residing in the areas targeted for vaccination (Forécariah and Boffa, Guinea). Data sources were household interviews with verification by vaccination card and notifications of adverse events from surveillance at vaccination posts and health centres. In total 5,248 people were included in the survey, 3,993 in Boffa and 1,255 in Forécariah. Overall, 89.4% [95%CI:86.4–91.8%] and 87.7% [95%CI:84.2–90.6%] were vaccinated during the first round and 79.8% [95%CI:75.6–83.4%] and 82.9% [95%CI:76.6–87.7%] during the second round in Boffa and Forécariah respectively. The two dose vaccine coverage (including card and oral reporting) was 75.8% [95%CI: 71.2–75.9%] in Boffa and 75.9% [95%CI: 69.8–80.9%] in Forécariah respectively. Vaccination coverage was higher in children. The main reason for non-vaccination was absence. No severe adverse events were notified. Conclusions/Significance The well-accepted mass vaccination campaign reached high coverage in a remote area with a mobile population. Although OCV should not be foreseen as the long-term solution for global cholera control, they should be

  13. Mapping Titan Cloud Coverage

    NASA Image and Video Library

    2010-09-21

    This graphic, constructed from data obtained by NASA Cassini spacecraft, shows the percentage of cloud coverage across the surface of Saturn moon Titan. The color scale from black to yellow signifies no cloud coverage to complete cloud coverage.

  14. Computation of mean and variance of the radiotherapy dose for PCA-modeled random shape and position variations of the target.

    PubMed

    Budiarto, E; Keijzer, M; Storchi, P R M; Heemink, A W; Breedveld, S; Heijmen, B J M

    2014-01-20

    Radiotherapy dose delivery in the tumor and surrounding healthy tissues is affected by movements and deformations of the corresponding organs between fractions. The random variations may be characterized by non-rigid, anisotropic principal component analysis (PCA) modes. In this article new dynamic dose deposition matrices, based on established PCA modes, are introduced as a tool to evaluate the mean and the variance of the dose at each target point resulting from any given set of fluence profiles. The method is tested for a simple cubic geometry and for a prostate case. The movements spread out the distributions of the mean dose and cause the variance of the dose to be highest near the edges of the beams. The non-rigidity and anisotropy of the movements are reflected in both quantities. The dynamic dose deposition matrices facilitate the inclusion of the mean and the variance of the dose in the existing fluence-profile optimizer for radiotherapy planning, to ensure robust plans with respect to the movements.

  15. Sensor-driven area coverage for an autonomous fixed-wing unmanned aerial vehicle.

    PubMed

    Paull, Liam; Thibault, Carl; Nagaty, Amr; Seto, Mae; Li, Howard

    2014-09-01

    Area coverage with an onboard sensor is an important task for an unmanned aerial vehicle (UAV) with many applications. Autonomous fixed-wing UAVs are more appropriate for larger scale area surveying since they can cover ground more quickly. However, their non-holonomic dynamics and susceptibility to disturbances make sensor coverage a challenging task. Most previous approaches to area coverage planning are offline and assume that the UAV can follow the planned trajectory exactly. In this paper, this restriction is removed as the aircraft maintains a coverage map based on its actual pose trajectory and makes control decisions based on that map. The aircraft is able to plan paths in situ based on sensor data and an accurate model of the on-board camera used for coverage. An information theoretic approach is used that selects desired headings that maximize the expected information gain over the coverage map. In addition, the branch entropy concept previously developed for autonomous underwater vehicles is extended to UAVs and ensures that the vehicle is able to achieve its global coverage mission. The coverage map over the workspace uses the projective camera model and compares the expected area of the target on the ground and the actual area covered on the ground by each pixel in the image. The camera is mounted on a two-axis gimbal and can either be stabilized or optimized for maximal coverage. Hardware-in-the-loop simulation results and real hardware implementation on a fixed-wing UAV show the effectiveness of the approach. By including the already developed automatic takeoff and landing capabilities, we now have a fully automated and robust platform for performing aerial imagery surveys.

  16. [Comparation study of incidental irradiation dose to the internal mammary chain during postmastectomy radiotherapy for patients treated with different irradiation techniques].

    PubMed

    Wang, W; Meng, Y T; Song, Y F; Sun, T; Xu, M; Shao, Q; Zhang, Y J; Li, J B

    2018-05-23

    Objective: To evaluated the unplanned coverage dose to the internal mammary chain (IMC) in patient treated with postmastectomy radiotherapy (PMRT). Methods: One hundred and thirty eight patients with breast cancer receiving radiotherapy (RT) in our hospital were retrospectively analyzed. Patients were divided into three groups: three-dimensional conformal radiotherapy (3D-CRT) group, forward intensity-modulated radiotherapy (F-IMRT) group and inverse IMRT (I-IMRT) group. The IMC were contoured according to Radiation Therapy Oncology Group (RTOG) consensus, and were not include into the planning target volume (PTV). The incidental irradiation dose to IMC among the three groups and the first three intercostal spaces IMC (ICS-IMC 1-3) were all compared, and explored the relationship between the mean doses (Dmean) of IMC and the OARs (ipsilateral lung and heart). Results: The dose delivered to IMC showed no difference in CRT, F-IMRT and I-IMRT(33.80 Gy, 29.65 Gy and 32.95 Gy). And 10.42%, 2.04%, and 9.76% patients achieved ≥45 Gy when treated with CRT, F-IMRT and I-IMRT. For the IMC dose in the first three intercostal spaces (ICS1-3), there was no difference to the three treatment plannings. The Dmean, V(20), V(30), V(40) and V(50) of the ICS-IMC2 and ICS-IMC3 were all obviously superior than ICS-IMC1 for all these three plannings. Moderate positive correlation was founded between Dmean for IMC and Dmean for heart for left breast cancer patients underwent CRT ( r =0.338, P =0.01). Whereas for F-IMRT and I-IMRT groups, positive correlation were founded between Dmean for IMC and Dmean and V(20) for ipsilateral lung for all patients (F-IMRT: r =0.366, P =0.010; r =0.318, P =0.026; I-IMRT: r =0.427, P =0.005; r =0.411, P =0.008). Conclusions: In 3D-CRT, F-IMRT and I-IMRT planning methods, partial patients get IMC irradiated doses that could achieve therapeutic doses. Compared with 3D-CRT, F-IMRT and I-IMRT further reduced the dose of irradiated organs. However, there is

  17. Dose, timing, schedule, and the choice of targeted epitope alter the efficacy of anti-CD22 immunotherapy in mice bearing human lymphoma xenografts.

    PubMed

    O'Donnell, Robert T; Ma, Yunpeng; McKnight, Hayes C; Pearson, David; Tuscano, Joseph M

    2009-12-01

    CD22 is a cell-surface adhesion molecule on most B-cell NHL, so it is a promising target for immunotherapy. HB22.7 is an anti-CD22 mAb that binds the two NH(2)-terminal immunoglobulin domains and specifically blocks the interaction of CD22 with its ligand. CD22-blocking mAbs induce apoptosis in neoplastic B-cells and are functionally distinguishable from other anti-CD22 mAbs. This study assessed the optimal dose, route, schedule, and the targeted CD22 epitope. Raji NHL-bearing nude mice were studied. A non-blocking anti-CD22 mAb (HB22.27) was used as a control. HB22.27 had minimal effect, whereas HB22.7 improved survival and shrank tumors substantially. HB22.7 doses greater than 1.4 mg/week did not further increase efficacy (or toxicity). Tumors less than 200 mm(3) had a higher response rate than did larger tumors. Various schedules of HB22.7 administration were tested; one dose every other week was more effective than more or less frequent dosing. Pharmacokinetic studies revealed that the half-life of HB22.7 was 28 days; this correlated with the time needed to re-populate cell-surface CD22 after treatment with HB22.7. Immuno-PET showed that NHL was rapidly and specifically targeted by copper-64-labeled-HB22.7. This study provided data as to an optimal dose, route, schedule and interval between doses of HB22.7.

  18. Two Birds With One Stone: Estimating Population Vaccination Coverage From a Test-negative Vaccine Effectiveness Case-control Study.

    PubMed

    Doll, Margaret K; Morrison, Kathryn T; Buckeridge, David L; Quach, Caroline

    2016-10-15

    Vaccination program evaluation includes assessment of vaccine uptake and direct vaccine effectiveness (VE). Often examined separately, we propose a design to estimate rotavirus vaccination coverage using controls from a rotavirus VE test-negative case-control study and to examine coverage following implementation of the Quebec, Canada, rotavirus vaccination program. We present our assumptions for using these data as a proxy for coverage in the general population, explore effects of diagnostic accuracy on coverage estimates via simulations, and validate estimates with an external source. We found 79.0% (95% confidence interval, 74.3%, 83.0%) ≥2-dose rotavirus coverage among participants eligible for publicly funded vaccination. No differences were detected between study and external coverage estimates. Simulations revealed minimal bias in estimates with high diagnostic sensitivity and specificity. We conclude that controls from a VE case-control study may be a valuable resource of coverage information when reasonable assumptions can be made for estimate generalizability; high rotavirus coverage demonstrates success of the Quebec program. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  19. Health Care Coverage Decision Making in Low- and Middle-Income Countries: Experiences from 25 Coverage Schemes.

    PubMed

    Gutierrez, Hialy; Shewade, Ashwini; Dai, Minghan; Mendoza-Arana, Pedro; Gómez-Dantés, Octavio; Jain, Nishant; Khonelidze, Irma; Nabyonga-Orem, Juliet; Saleh, Karima; Teerawattananon, Yot; Nishtar, Sania; Hornberger, John

    2015-08-01

    Lessons learned by countries that have successfully implemented coverage schemes for health services may be valuable for other countries, especially low- and middle-income countries (LMICs), which likewise are seeking to provide/expand coverage. The research team surveyed experts in population health management from LMICs for information on characteristics of health care coverage schemes and factors that influenced decision-making processes. The level of coverage provided by the different schemes varied. Nearly all the health care coverage schemes involved various representatives and stakeholders in their decision-making processes. Maternal and child health, cardiovascular diseases, cancer, and HIV were among the highest priorities guiding coverage development decisions. Evidence used to inform coverage decisions included medical literature, regional and global epidemiology, and coverage policies of other coverage schemes. Funding was the most commonly reported reason for restricting coverage. This exploratory study provides an overview of health care coverage schemes from participating LMICs and contributes to the scarce evidence base on coverage decision making. Sharing knowledge and experiences among LMICs can support efforts to establish systems for accessible, affordable, and equitable health care.

  20. Helical Tomotherapy vs. Intensity-Modulated Proton Therapy for Whole Pelvis Irradiation in High-Risk Prostate Cancer Patients: Dosimetric, Normal Tissue Complication Probability, and Generalized Equivalent Uniform Dose Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Widesott, Lamberto, E-mail: widesott@yahoo.it; Pierelli, Alessio; Fiorino, Claudio

    2011-08-01

    Purpose: To compare intensity-modulated proton therapy (IMPT) and helical tomotherapy (HT) treatment plans for high-risk prostate cancer (HRPCa) patients. Methods and Materials: The plans of 8 patients with HRPCa treated with HT were compared with IMPT plans with two quasilateral fields set up (-100{sup o}; 100{sup o}) and optimized with the Hyperion treatment planning system. Both techniques were optimized to simultaneously deliver 74.2 Gy/Gy relative biologic effectiveness (RBE) in 28 fractions on planning target volumes (PTVs)3-4 (P + proximal seminal vesicles), 65.5 Gy/Gy(RBE) on PTV2 (distal seminal vesicles and rectum/prostate overlapping), and 51.8 Gy/Gy(RBE) to PTV1 (pelvic lymph nodes). Normalmore » tissue calculation probability (NTCP) calculations were performed for the rectum, and generalized equivalent uniform dose (gEUD) was estimated for the bowel cavity, penile bulb and bladder. Results: A slightly better PTV coverage and homogeneity of target dose distribution with IMPT was found: the percentage of PTV volume receiving {>=}95% of the prescribed dose (V{sub 95%}) was on average >97% in HT and >99% in IMPT. The conformity indexes were significantly lower for protons than for photons, and there was a statistically significant reduction of the IMPT dosimetric parameters, up to 50 Gy/Gy(RBE) for the rectum and bowel and 60 Gy/Gy(RBE) for the bladder. The NTCP values for the rectum were higher in HT for all the sets of parameters, but the gain was small and in only a few cases statistically significant. Conclusions: Comparable PTV coverage was observed. Based on NTCP calculation, IMPT is expected to allow a small reduction in rectal toxicity, and a significant dosimetric gain with IMPT, both in medium-dose and in low-dose range in all OARs, was observed.« less

  1. A dose optimization method for electron radiotherapy using randomized aperture beams

    NASA Astrophysics Data System (ADS)

    Engel, Konrad; Gauer, Tobias

    2009-09-01

    The present paper describes the entire optimization process of creating a radiotherapy treatment plan for advanced electron irradiation. Special emphasis is devoted to the selection of beam incidence angles and beam energies as well as to the choice of appropriate subfields generated by a refined version of intensity segmentation and a novel random aperture approach. The algorithms have been implemented in a stand-alone programme using dose calculations from a commercial treatment planning system. For this study, the treatment planning system Pinnacle from Philips has been used and connected to the optimization programme using an ASCII interface. Dose calculations in Pinnacle were performed by Monte Carlo simulations for a remote-controlled electron multileaf collimator (MLC) from Euromechanics. As a result, treatment plans for breast cancer patients could be significantly improved when using randomly generated aperture beams. The combination of beams generated through segmentation and randomization achieved the best results in terms of target coverage and sparing of critical organs. The treatment plans could be further improved by use of a field reduction algorithm. Without a relevant loss in dose distribution, the total number of MLC fields and monitor units could be reduced by up to 20%. In conclusion, using randomized aperture beams is a promising new approach in radiotherapy and exhibits potential for further improvements in dose optimization through a combination of randomized electron and photon aperture beams.

  2. Effectiveness of interventions that apply new media to improve vaccine uptake and vaccine coverage.

    PubMed

    Odone, Anna; Ferrari, Antonio; Spagnoli, Francesca; Visciarelli, Sara; Shefer, Abigail; Pasquarella, Cesira; Signorelli, Carlo

    2015-01-01

    Vaccine-preventable diseases (VPD) are still a major cause of morbidity and mortality worldwide. In high and middle-income settings, immunization coverage is relatively high. However, in many countries coverage rates of routinely recommended vaccines are still below the targets established by international and national advisory committees. Progress in the field of communication technology might provide useful tools to enhance immunization strategies. To systematically collect and summarize the available evidence on the effectiveness of interventions that apply new media to promote vaccination uptake and increase vaccination coverage. We conducted a systematic literature review. Studies published from January 1999 to September 2013 were identified by searching electronic resources (Pubmed, Embase), manual searches of references and expert consultation. Study setting We focused on interventions that targeted recommended vaccinations for children, adolescents and adults and: (1) aimed at increasing community demand for immunizations, or (2) were provider-based interventions. We limited the study setting to countries that are members of the Organisation for Economic Co-operation and Development (OECD). The primary outcome was a measure of vaccination (vaccine uptake or vaccine coverage). Considered secondary outcomes included willingness to receive immunization, attitudes and perceptions toward vaccination, and perceived helpfulness of the intervention. Nineteen studies were included in the systematic review. The majority of the studies were conducted in the US (74%, n = 14); 68% (n = 13) of the studies were experimental, the rest having an observational study design. Eleven (58%) reported results on the primary outcome. Retrieved studies explored the role of: text messaging (n.7, 37%), smartphone applications (n.1, 5%), Youtube videos (n.1, 5%), Facebook (n.1, 5%), targeted websites and portals (n.4, 21%), software for physicians and health professionals (n.4, 21

  3. Effectiveness of interventions that apply new media to improve vaccine uptake and vaccine coverage

    PubMed Central

    Odone, Anna; Ferrari, Antonio; Spagnoli, Francesca; Visciarelli, Sara; Shefer, Abigail; Pasquarella, Cesira; Signorelli, Carlo

    2014-01-01

    Background Vaccine-preventable diseases (VPD) are still a major cause of morbidity and mortality worldwide. In high and middle-income settings, immunization coverage is relatively high. However, in many countries coverage rates of routinely recommended vaccines are still below the targets established by international and national advisory committees. Progress in the field of communication technology might provide useful tools to enhance immunization strategies. Objective To systematically collect and summarize the available evidence on the effectiveness of interventions that apply new media to promote vaccination uptake and increase vaccination coverage. Design We conducted a systematic literature review. Studies published from January 1999 to September 2013 were identified by searching electronic resources (Pubmed, Embase), manual searches of references and expert consultation. Study setting We focused on interventions that targeted recommended vaccinations for children, adolescents and adults and: (1) aimed at increasing community demand for immunizations, or (2) were provider-based interventions. We limited the study setting to countries that are members of the Organisation for Economic Co-operation and Development (OECD). Main outcome measures The primary outcome was a measure of vaccination (vaccine uptake or vaccine coverage). Considered secondary outcomes included willingness to receive immunization, attitudes and perceptions toward vaccination, and perceived helpfulness of the intervention. Results Nineteen studies were included in the systematic review. The majority of the studies were conducted in the US (74%, n = 14); 68% (n = 13) of the studies were experimental, the rest having an observational study design. Eleven (58%) reported results on the primary outcome. Retrieved studies explored the role of: text messaging (n.7, 37%), smartphone applications (n.1, 5%), Youtube videos (n.1, 5%), Facebook (n.1, 5%), targeted websites and portals (n.4, 21

  4. A reflection on invasive pneumococcal disease and pneumococcal conjugate vaccination coverage in children in Southern Europe (2009-2016).

    PubMed

    Moreira, Marta; Castro, Olga; Palmieri, Melissa; Efklidou, Sofia; Castagna, Stefano; Hoet, Bernard

    2017-06-03

    Higher-valent pneumococcal conjugate vaccines (PCVs) were licensed from 2009 in Europe; similar worldwide clinical effectiveness was observed for PCVs in routine use. Despite a proven medical need, PCV vaccination in Southern Europe remained suboptimal until 2015/16. We searched PubMed for manuscripts published between 2009 and mid-2016. Included manuscripts had to contain data about invasive pneumococcal disease (IPD) incidence, or vaccination coverage with higher-valent PCVs. This review represents the first analysis of vaccination coverage and impact of higher-valent PCVs on overall IPD in Southern European countries (Portugal, Spain, Italy, Greece, Cyprus). Vaccination coverage in the Portuguese private market peaked around 2008 at 75% (children ≤ 2 years) but declined to 63% in 2012. In Madrid, coverage was 95% (2007-2012) but dropped to 67% (2013/14; children ≤ 2 years) after funding termination in May 2012. PCVs were recently introduced in the national immunisation program (NIP) of Portugal (2015) and Spain (2015/16). In Italy, coverage for the complete PCV schedule (children ≤ 2 years) was 88% in 2013, although highly variable between regions (45-99%). In Greece, in 2013, 82.3% had received 3 PCV doses by 12 months, while 62.3% received the fourth dose by 24 months. Overall IPD (net benefit: effect on vaccine types, vaccine-related types, and non-vaccine types) has decreased; in Greece, pneumococcal meningitis incidence remained stable. Continued IPD surveillance or national registers using ICD-10 codes of clinically suspected IPD are necessary, with timely publicly available reports and adequate national vaccination registers to assess trends in vaccination coverage, allowing evaluation of PCVs in NIPs.

  5. Radon Exposure and the Definition of Low Doses-The Problem of Spatial Dose Distribution.

    PubMed

    Madas, Balázs G

    2016-07-01

    Investigating the health effects of low doses of ionizing radiation is considered to be one of the most important fields in radiological protection research. Although the definition of low dose given by a dose range seems to be clear, it leaves some open questions. For example, the time frame and the target volume in which absorbed dose is measured have to be defined. While dose rate is considered in the current system of radiological protection, the same cancer risk is associated with all exposures, resulting in a given amount of energy absorbed by a single target cell or distributed among all the target cells of a given organ. However, the biological effects and so the health consequences of these extreme exposure scenarios are unlikely to be the same. Due to the heterogeneous deposition of radon progeny within the lungs, heterogeneous radiation exposure becomes a practical issue in radiological protection. While the macroscopic dose is still within the low dose range, local tissue doses on the order of Grays can be reached in the most exposed parts of the bronchial airways. It can be concluded that progress in low dose research needs not only low dose but also high dose experiments where small parts of a biological sample receive doses on the order of Grays, while the average dose over the whole sample remains low. A narrow interpretation of low dose research might exclude investigations with high relevance to radiological protection. Therefore, studies important to radiological protection should be performed in the frame of low dose research even if the applied doses do not fit in the dose range used for the definition of low doses.

  6. Strategies for Coordination of a Serosurvey in Parallel with an Immunization Coverage Survey

    PubMed Central

    Travassos, Mark A.; Beyene, Berhane; Adam, Zenaw; Campbell, James D.; Mulholland, Nigisti; Diarra, Seydou S.; Kassa, Tassew; Oot, Lisa; Sequeira, Jenny; Reymann, Mardi; Blackwelder, William C.; Pasetti, Marcela F.; Sow, Samba O.; Steinglass, Robert; Kebede, Amha; Levine, Myron M.

    2015-01-01

    A community-based immunization coverage survey is the standard way to estimate effective vaccination delivery to a target population in a region. Accompanying serosurveys can provide objective measures of protective immunity against vaccine-preventable diseases but pose considerable challenges with respect to specimen collection and preservation and community compliance. We performed serosurveys coupled to immunization coverage surveys in three administrative districts (woredas) in rural Ethiopia. Critical to the success of this effort were serosurvey equipment and supplies, team composition, and tight coordination with the coverage survey. Application of these techniques to future studies may foster more widespread use of serosurveys to derive more objective assessments of vaccine-derived seroprotection and monitor and compare the performance of immunization services in different districts of a country. PMID:26055737

  7. SU-E-CAMPUS-I-06: Y90 PET/CT for the Instantaneous Determination of Both Target and Non-Target Absorbed Doses Following Hepatic Radioembolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pasciak, A; Kao, J

    2014-06-15

    Purpose The process of converting Yttrium-90 (Y90) PET/CT images into 3D absorbed dose maps will be explained. The simple methods presented will allow the medical physicst to analyze Y90 PET images following radioembolization and determine the absorbed dose to tumor, normal liver parenchyma and other areas of interest, without application of Monte-Carlo radiation transport or dose-point-kernel (DPK) convolution. Methods Absorbed dose can be computed from Y90 PET/CT images based on the premise that radioembolization is a permanent implant with a constant relative activity distribution after infusion. Many Y90 PET/CT publications have used DPK convolution to obtain 3D absorbed dose maps.more » However, this method requires specialized software limiting clinical utility. The Local Deposition method, an alternative to DPK convolution, can be used to obtain absorbed dose and requires no additional computer processing. Pixel values from regions of interest drawn on Y90 PET/CT images can be converted to absorbed dose (Gy) by multiplication with a scalar constant. Results There is evidence that suggests the Local Deposition method may actually be more accurate than DPK convolution and it has been successfully used in a recent Y90 PET/CT publication. We have analytically compared dose-volume-histograms (DVH) for phantom hot-spheres to determine the difference between the DPK and Local Deposition methods, as a function of PET scanner point-spread-function for Y90. We have found that for PET/CT systems with a FWHM greater than 3.0 mm when imaging Y90, the Local Deposition Method provides a more accurate representation of DVH, regardless of target size than DPK convolution. Conclusion Using the Local Deposition Method, post-radioembolization Y90 PET/CT images can be transformed into 3D absorbed dose maps of the liver. An interventional radiologist or a Medical Physicist can perform this transformation in a clinical setting, allowing for rapid prediction of treatment efficacy

  8. Variation in cervical and breast cancer screening coverage in England: a cross-sectional analysis to characterise districts with atypical behaviour.

    PubMed

    Massat, Nathalie J; Douglas, Elaine; Waller, Jo; Wardle, Jane; Duffy, Stephen W

    2015-07-24

    Reducing cancer screening inequalities in England is a major focus of the 2011 Department of Health cancer outcome strategy. Screening coverage requires regular monitoring in order to implement targeted interventions where coverage is low. This study aimed to characterise districts with atypical coverage levels for cervical or breast screening. Observational study of district-level coverage in the English Cervical and Breast screening programmes in 2012. England, UK. All English women invited to participate in the cervical (age group 25-49 and 50-64) and breast (age group 50-64) screening programmes. Risk adjustment models for coverage were developed based on district-level characteristics. Funnel plots of adjusted coverage were constructed, and atypical districts examined by correlation analysis. Variability in coverage was primarily explained by population factors, whereas general practice characteristics had little independent effect. Deprivation and ethnicity other than white, Asian, black or mixed were independently associated with poorer coverage in both screening programmes, with ethnicity having the strongest effect; by comparison, the influence of Asian, black or mixed ethnic minority was limited. Deprivation, ethnicity and urbanisation largely accounted for the lower cervical screening coverage in London. However, for breast screening, being located in London remained a strong negative predictor. A subset of districts was identified as having atypical coverage across programmes. Correlates of deprivation in districts with relatively low adjusted coverage were substantially different from overall correlates of deprivation. These results inform the continuing drive to reduce avoidable cancer deaths in England, and encourage implementation of targeted interventions in communities residing in districts identified as having atypically low coverage. Sequential implementation to monitor the impact of local interventions would help accrue evidence on 'what works

  9. Variation in cervical and breast cancer screening coverage in England: a cross-sectional analysis to characterise districts with atypical behaviour

    PubMed Central

    Massat, Nathalie J; Douglas, Elaine; Waller, Jo; Wardle, Jane; Duffy, Stephen W

    2015-01-01

    Objectives Reducing cancer screening inequalities in England is a major focus of the 2011 Department of Health cancer outcome strategy. Screening coverage requires regular monitoring in order to implement targeted interventions where coverage is low. This study aimed to characterise districts with atypical coverage levels for cervical or breast screening. Design Observational study of district-level coverage in the English Cervical and Breast screening programmes in 2012. Setting England, UK. Participants All English women invited to participate in the cervical (age group 25–49 and 50–64) and breast (age group 50–64) screening programmes. Outcomes Risk adjustment models for coverage were developed based on district-level characteristics. Funnel plots of adjusted coverage were constructed, and atypical districts examined by correlation analysis. Results Variability in coverage was primarily explained by population factors, whereas general practice characteristics had little independent effect. Deprivation and ethnicity other than white, Asian, black or mixed were independently associated with poorer coverage in both screening programmes, with ethnicity having the strongest effect; by comparison, the influence of Asian, black or mixed ethnic minority was limited. Deprivation, ethnicity and urbanisation largely accounted for the lower cervical screening coverage in London. However, for breast screening, being located in London remained a strong negative predictor. A subset of districts was identified as having atypical coverage across programmes. Correlates of deprivation in districts with relatively low adjusted coverage were substantially different from overall correlates of deprivation. Discussion These results inform the continuing drive to reduce avoidable cancer deaths in England, and encourage implementation of targeted interventions in communities residing in districts identified as having atypically low coverage. Sequential implementation to monitor the

  10. Strengthening routine immunization systems to improve global vaccination coverage.

    PubMed

    Sodha, S V; Dietz, V

    2015-03-01

    Global coverage with the third dose of diphtheria-tetanus-pertussis vaccine among children under 1 year of age stagnated at ∼ 83-84% during 2008-13. Annual World Health Organization and UNICEF-derived national vaccination coverage estimates. Incomplete vaccination is associated with poor socioeconomic status, lower education, non-use of maternal-child health services, living in conflict-affected areas, missed immunization opportunities and cancelled vaccination sessions. Vaccination platforms must expand to include older ages including the second year of life. Immunization programmes, including eradication and elimination initiatives such as those for polio and measles, must integrate within the broader health system. The Global Vaccine Action Plan (GVAP) 2011-20 is a framework for strengthening immunization systems, emphasizing country ownership, shared responsibility, equity, integration, sustainability and innovation. Immunization programmes should identify, monitor and evaluate gaps and interventions within the GVAP framework. Published by Oxford University Press 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  11. Feasibility study on inverse four-dimensional dose reconstruction using the continuous dose-image of EPID

    PubMed Central

    Yeo, Inhwan Jason; Jung, Jae Won; Yi, Byong Yong; Kim, Jong Oh

    2013-01-01

    Purpose: When an intensity-modulated radiation beam is delivered to a moving target, the interplay effect between dynamic beam delivery and the target motion due to miss-synchronization can cause unpredictable dose delivery. The portal dose image in electronic portal imaging device (EPID) represents radiation attenuated and scattered through target media. Thus, it may possess information about delivered radiation to the target. Using a continuous scan (cine) mode of EPID, which provides temporal dose images related to target and beam movements, the authors’ goal is to perform four-dimensional (4D) dose reconstruction. Methods: To evaluate this hypothesis, first, the authors have derived and subsequently validated a fast method of dose reconstruction based on virtual beamlet calculations of dose responses using a test intensity-modulated beam. This method was necessary for processing a large number of EPID images pertinent for four-dimensional reconstruction. Second, cine mode acquisition after summation over all images was validated through comparison with integration mode acquisition on EPID (IAS3 and aS1000) for the test beam. This was to confirm the agreement of the cine mode with the integrated mode, specifically for the test beam, which is an accepted mode of image acquisition for dosimetry with EPID. Third, in-phantom film and exit EPID dosimetry was performed on a moving platform using the same beam. Heterogeneous as well as homogeneous phantoms were used. The cine images were temporally sorted at 10% interval. The authors have performed dose reconstruction to the in-phantom plane from the sorted cine images using the above validated method of dose reconstruction. The reconstructed dose from each cine image was summed to compose a total reconstructed dose from the test beam delivery, and was compared with film measurements. Results: The new method of dose reconstruction was validated showing greater than 95.3% pass rates of the gamma test with the criteria

  12. Dosimetric effects of Onyx embolization on Gamma Knife arteriovenous malformation dose distributions.

    PubMed

    Schlesinger, David J; Nordström, Håkan; Lundin, Anders; Xu, Zhiyuan; Sheehan, Jason P

    2016-12-01

    OBJECTIVE Patients with arteriovenous malformations (AVMs) treated with Gamma Knife radiosurgery (GKRS) subsequent to embolization suffer from elevated local failure rates and differences in adverse radiation effects. Onyx is a common embolic material for AVMs. Onyx is formulated with tantalum, a high atomic number (Z = 73) element that has been investigated as a source of dosimetric uncertainty contributing to the less favorable clinical results. However, prior studies have not modeled the complicated anatomical and beam geometries characteristic of GKRS. This study investigated the magnitude of dose perturbation that can occur due to Onyx embolization using clinically realistic anatomical and Gamma Knife beam models. METHODS Leksell GammaPlan (LGP) was used to segment the AVM nidus and areas of Onyx from postcontrast stereotactic MRI for 7 patients treated with GKRS postembolization. The resulting contours, skull surface, and clinically selected dose distributions were exported from LGP in DICOM-RT (Digital Imaging and Communications in Medicine-radiotherapy) format. Isocenter locations and dwell times were recorded from the LGP database. Contours were converted into 3D mesh representations using commercial and in-house mesh-editing software. The resulting data were imported into a Monte Carlo (MC) dose calculation engine (Pegasos, Elekta Instruments AB) with a beam geometry for the Gamma Knife Perfexion. The MC-predicted dose distributions were calculated with Onyx assigned manufacturer-reported physical constants (MC-Onyx), and then compared with corresponding distributions in which Onyx was reassigned constants for water (MC-water). Differences in dose metrics were determined, including minimum, maximum, and mean dose to the AVM nidus; selectivity index; and target coverage. Combined differences in dose magnitude and distance to agreement were calculated as 3D Gamma analysis passing rates using tolerance criteria of 0.5%/0.5 mm, 1.0%/1.0 mm, and 3.0%/3.0 mm

  13. Use of Lot Quality Assurance Sampling (LQAS) to estimate vaccination coverage helps guide future vaccination efforts.

    PubMed

    Alberti, K P; Guthmann, J P; Fermon, F; Nargaye, K D; Grais, R F

    2008-03-01

    Inadequate evaluation of vaccine coverage after mass vaccination campaigns, such as used in national measles control programmes, can lead to inappropriate public health responses. Overestimation of vaccination coverage may leave populations at risk, whilst underestimation can lead to unnecessary catch-up campaigns. The problem is more complex in large urban areas where vaccination coverage may be heterogeneous and the programme may have to be fine-tuned at the level of geographic subunits. Lack of accurate population figures in many contexts further complicates accurate vaccination coverage estimates. During the evaluation of a mass vaccination campaign carried out in N'Djamena, the capital of Chad, Lot Quality Assurance Sampling was used to estimate vaccination coverage. Using this method, vaccination coverage could be evaluated within smaller geographic areas of the city as well as for the entire city. Despite the lack of accurate population data by neighbourhood, the results of the survey showed heterogeneity of vaccination coverage within the city. These differences would not have been identified using a more traditional method. The results can be used to target areas of low vaccination coverage during follow-up vaccination activities.

  14. Building multidevice pipeline constructs of favorable metal coverage: a practical guide.

    PubMed

    Shapiro, M; Raz, E; Becske, T; Nelson, P K

    2014-08-01

    The advent of low-porosity endoluminal devices, also known as flow diverters, exemplified by the Pipeline in the United States, produced the greatest paradigm shift in cerebral aneurysm treatment since the introduction of detachable coils. Despite robust evidence of efficacy and safety, key questions regarding the manner of their use remain unanswered. Recent studies demonstrated that the Pipeline device geometry can dramatically affect its metal coverage, emphasizing the negative effects of oversizing the device relative to its target vessels. This follow-up investigation focuses on the geometry and coverage of multidevice constructs. A number of Pipeline devices were deployed in tubes of known diameters and photographed, and the resultant coverage was determined by image segmentation. Multidevice segmentation images were created to study the effects of telescoped devices and provide an estimate of coverages resulting from device overlap. Double overlap yields a range of metal coverage, rather than a single value, determined by the diameters of both devices, the size of the recipient artery, and the degree to which strands of the overlapped devices are coregistered with each other. The potential variation in coverage is greatest during overlap of identical-diameter devices, for example, ranging from 24% to 41% for two 3.75-mm devices deployed in a 3.5-mm vessel. Overlapping devices of progressively different diameters produce correspondingly more uniform ranges of coverage, though reducing the maximum achievable value, for example, yielding a 33%-34% range for 3.75- and 4.75-mm devices deployed in the same 3.5-mm vessel. Rational strategies for building multidevice constructs can achieve favorable geometric outcomes. © 2014 by American Journal of Neuroradiology.

  15. 5 CFR 837.301 - Coverage.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 2 2012-01-01 2012-01-01 false Coverage. 837.301 Section 837.301...) REEMPLOYMENT OF ANNUITANTS Coverage and Contributions § 837.301 Coverage. (a) When annuity terminates on, or is suspended during, reemployment. Retirement coverage under either CSRS or FERS is governed by subpart B of...

  16. 5 CFR 837.301 - Coverage.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Coverage. 837.301 Section 837.301...) REEMPLOYMENT OF ANNUITANTS Coverage and Contributions § 837.301 Coverage. (a) When annuity terminates on, or is suspended during, reemployment. Retirement coverage under either CSRS or FERS is governed by subpart B of...

  17. 5 CFR 837.301 - Coverage.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 2 2014-01-01 2014-01-01 false Coverage. 837.301 Section 837.301...) REEMPLOYMENT OF ANNUITANTS Coverage and Contributions § 837.301 Coverage. (a) When annuity terminates on, or is suspended during, reemployment. Retirement coverage under either CSRS or FERS is governed by subpart B of...

  18. 5 CFR 890.1106 - Coverage.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 2 2012-01-01 2012-01-01 false Coverage. 890.1106 Section 890.1106... EMPLOYEES HEALTH BENEFITS PROGRAM Temporary Continuation of Coverage § 890.1106 Coverage. (a) Type of enrollment. An individual who enrolls under this subpart may elect coverage for self alone or self and family...

  19. 5 CFR 837.301 - Coverage.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 2 2011-01-01 2011-01-01 false Coverage. 837.301 Section 837.301...) REEMPLOYMENT OF ANNUITANTS Coverage and Contributions § 837.301 Coverage. (a) When annuity terminates on, or is suspended during, reemployment. Retirement coverage under either CSRS or FERS is governed by subpart B of...

  20. 5 CFR 837.301 - Coverage.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 5 Administrative Personnel 2 2013-01-01 2013-01-01 false Coverage. 837.301 Section 837.301...) REEMPLOYMENT OF ANNUITANTS Coverage and Contributions § 837.301 Coverage. (a) When annuity terminates on, or is suspended during, reemployment. Retirement coverage under either CSRS or FERS is governed by subpart B of...

  1. 5 CFR 890.1106 - Coverage.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 2 2014-01-01 2014-01-01 false Coverage. 890.1106 Section 890.1106... EMPLOYEES HEALTH BENEFITS PROGRAM Temporary Continuation of Coverage § 890.1106 Coverage. (a) Type of enrollment. An individual who enrolls under this subpart may elect coverage for self alone or self and family...

  2. 5 CFR 890.1106 - Coverage.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 2 2011-01-01 2011-01-01 false Coverage. 890.1106 Section 890.1106... EMPLOYEES HEALTH BENEFITS PROGRAM Temporary Continuation of Coverage § 890.1106 Coverage. (a) Type of enrollment. An individual who enrolls under this subpart may elect coverage for self alone or self and family...

  3. 5 CFR 890.1106 - Coverage.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 5 Administrative Personnel 2 2013-01-01 2013-01-01 false Coverage. 890.1106 Section 890.1106... EMPLOYEES HEALTH BENEFITS PROGRAM Temporary Continuation of Coverage § 890.1106 Coverage. (a) Type of enrollment. An individual who enrolls under this subpart may elect coverage for self alone or self and family...

  4. SU-F-J-13: Choosing An IMRT Technique in the Treatment of Head and Neck Cancer with Daily Localization Uncertainties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, T; Wang, L; Galloway, T

    Purpose: Head and Neck cancer treatment with IMRT/VMAT has two choices: split-filed IMRT(SFI), in which the LAN is treated with a separate anterior field and the extended whole-field IMRT(WFI) in which LAN is included with the IMRT/VMAT field. This study shows that under the same dose limit criteria, choosing the technique becomes a critical issue if daily localization and immobilization altered the dose distribution. Methods: Nine common head-and-neck cancer cases were chosen to illustrate how the daily localization and immobilization uncertainties affect to choose between SFI and WFI. Both SFI and WFI at upper target coverage were generated with VMAT.more » For each case, the same planning criteria were applied to the target and critical structures; therefore, similar target coverage and dose falloff can be observed in both techniques. Thirty days of kV cone beam CT(CBCT) images on each case were also delineated with contralateral and ipsilateral target as well as larynx as critical structure. About 300 CBCT images with daily delivered doses were analyzed and compared in a form of dose-volume histograms. Results: While both plans for SFI and WFI with VMAT planning utilized and meet the criteria of D95>prescription dose and for not-involved larynx with mean dose <35Gy and V55<10%, the daily localization and immobilization has a great contribution to the resulted dose delivery. With WFI, the better daily contralateral and ipsilateral neck target coverage can reflect a simpler or shorter localization; however, a much superior avoidance (WFI: mean dose a 42.5Gy; SFI: mean dose a 18.9Gy) of the non-involved larynx from the SFI is preferred. Conclusion: Dosimetrically, SFI and WFI are equally well for head and Neck cancer treatment with VMAT technique; however, if considering the contribution of daily localization(CBCT) method uncertainties, SFI is better with sparing non-involved larynx and WFI has better target coverage.« less

  5. SU-C-BRB-02: Automatic Planning as a Potential Strategy for Dose Escalation for Pancreas SBRT?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, S; Zheng, D; Ma, R

    Purpose: Stereotactic body radiation therapy (SBRT) has been suggested to provide high rates of local control for locally advanced pancreatic cancer. However, the close proximity of highly radiosensitive normal tissues usually causes the labor-intensive planning process, and may impede further escalation of the prescription dose. The present study evaluates the potential of an automatic planning system as a dose escalation strategy. Methods: Ten pancreatic cancer patients treated with SBRT were studied retrospectively. SBRT was delivered over 5 consecutive fractions with 6 ∼ 8Gy/fraction. Two plans were generated by Pinnacle Auto-Planning with the original prescription and escalated prescription, respectively. Escalated prescriptionmore » adds 1 Gy/fraction to the original prescription. Manually-created planning volumes were excluded in the optimization goals in order to assess the planning efficiency and quality simultaneously. Critical organs with closest proximity were used to determine the plan normalization to ensure the OAR sparing. Dosimetric parameters including D100, and conformity index (CI) were assessed. Results: Auto-plans directly generate acceptable plans for 70% of the cases without necessity of further improvement, and two more iterations at most are necessary for the rest of the cases. For the pancreas SBRT plans with the original prescription, autoplans resulted in favorable target coverage and PTV conformity (D100 = 96.3% ± 1.48%; CI = 0.88 ± 0.06). For the plans with the escalated prescriptions, no significant target under-dosage was observed, and PTV conformity remains reasonable (D100 = 93.3% ± 3.8%, and CI = 0.84 ± 0.05). Conclusion: Automatic planning, without substantial human-intervention process, results in reasonable PTV coverage and PTV conformity on the premise of adequate OAR sparing for the pancreas SBRT plans with escalated prescription. The results highlight the potential of autoplanning as a dose escalation strategy for

  6. Multiple anatomy optimization of accumulated dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Watkins, W. Tyler, E-mail: watkinswt@virginia.edu; Siebers, Jeffrey V.; Moore, Joseph A.

    Purpose: To investigate the potential advantages of multiple anatomy optimization (MAO) for lung cancer radiation therapy compared to the internal target volume (ITV) approach. Methods: MAO aims to optimize a single fluence to be delivered under free-breathing conditions such that the accumulated dose meets the plan objectives, where accumulated dose is defined as the sum of deformably mapped doses computed on each phase of a single four dimensional computed tomography (4DCT) dataset. Phantom and patient simulation studies were carried out to investigate potential advantages of MAO compared to ITV planning. Through simulated delivery of the ITV- and MAO-plans, target dosemore » variations were also investigated. Results: By optimizing the accumulated dose, MAO shows the potential to ensure dose to the moving target meets plan objectives while simultaneously reducing dose to organs at risk (OARs) compared with ITV planning. While consistently superior to the ITV approach, MAO resulted in equivalent OAR dosimetry at planning objective dose levels to within 2% volume in 14/30 plans and to within 3% volume in 19/30 plans for each lung V20, esophagus V25, and heart V30. Despite large variations in per-fraction respiratory phase weights in simulated deliveries at high dose rates (e.g., treating 4/10 phases during single fraction beams) the cumulative clinical target volume (CTV) dose after 30 fractions and per-fraction dose were constant independent of planning technique. In one case considered, however, per-phase CTV dose varied from 74% to 117% of prescription implying the level of ITV-dose heterogeneity may not be appropriate with conventional, free-breathing delivery. Conclusions: MAO incorporates 4DCT information in an optimized dose distribution and can achieve a superior plan in terms of accumulated dose to the moving target and OAR sparing compared to ITV-plans. An appropriate level of dose heterogeneity in MAO plans must be further investigated.« less

  7. CBCT volumetric coverage extension using a pair of complementary circular scans with complementary kV detector lateral and longitudinal offsets

    NASA Astrophysics Data System (ADS)

    Yang, Deshan; Li, H. Harold; Goddu, S. Murty; Tan, Jun

    2014-10-01

    Onboard cone-beam CT (CBCT) has been widely used in image guided radiation therapy. However, the longitudinal coverage is only 15.5 cm in the pelvis scan mode. As a result, a single CBCT scan cannot cover the planning target volume in the longitudinal direction for over 80% of the patients. The common approach is to use double- or multiple-circular scans and then combine multiple CBCT volumes after reconstruction. However it raises concerns regarding doubled imaging dose at the imaging beam junctions due to beam divergence. In this work, we present a new method, DSCS (Dual Scan with Complementary Shifts), to address the CBCT coverage problem using a pair of complementary circular scans. In DSCS, two circular scans were performed at 39.5 cm apart longitudinally. In the superior scan, the detector panel was offset by 16 cm to the left, 15 cm to the inferior. In the inferior scan, the detector panel was shifted 16 cm to the right and 15 cm to the superior. The effective imaging volume is 39.5 cm longitudinally with a 45 cm lateral field-of-view (FOV). Half beam blocks were used to confine the imaging radiation inside the volume of interest. A new image reconstruction algorithm was developed, based on the Feldkamp-Davis-Kress cone-beam CT reconstruction algorithm, to support the DSCS scanning geometry. Digital phantom simulations were performed to demonstrate the feasibility of DSCS. Physical phantom studies were performed using an anthropomorphic phantom on a commercial onboard CBCT system. With basic scattering corrections, the reconstruction results were acceptable. Other issues, including the discrepancy in couch vertical at different couch longitudinal positions, and the inaccuracy in couch table longitudinal movement, were manually corrected during the reconstruction process. In conclusion, the phantom studies showed that, using DSCS, a 39.5 cm longitudinal coverage with a 45 cm FOV was accomplished. The efficiency of imaging dose usage was

  8. Planning magnetic resonance imaging for prostate cancer intensity-modulated radiation therapy: Impact on target volumes, radiotherapy dose and androgen deprivation administration.

    PubMed

    Horsley, Patrick J; Aherne, Noel J; Edwards, Grace V; Benjamin, Linus C; Wilcox, Shea W; McLachlan, Craig S; Assareh, Hassan; Welshman, Richard; McKay, Michael J; Shakespeare, Thomas P

    2015-03-01

    Magnetic resonance imaging (MRI) scans are increasingly utilized for radiotherapy planning to contour the primary tumors of patients undergoing intensity-modulated radiation therapy (IMRT). These scans may also demonstrate cancer extent and may affect the treatment plan. We assessed the impact of planning MRI detection of extracapsular extension, seminal vesicle invasion, or adjacent organ invasion on the staging, target volume delineation, doses, and hormonal therapy of patients with prostate cancer undergoing IMRT. The records of 509 consecutive patients with planning MRI scans being treated with IMRT for prostate cancer between January 2010 and July 2012 were retrospectively reviewed. Tumor staging and treatment plans before and after MRI were compared. Of the 509 patients, 103 (20%) were upstaged and 44 (9%) were migrated to a higher risk category as a result of findings at MRI. In 94 of 509 patients (18%), the MRI findings altered management. Ninety-four of 509 patients (18%) had a change to their clinical target volume (CTV) or treatment technique, and in 41 of 509 patients (8%) the duration of hormone therapy was changed because of MRI findings. The use of radiotherapy planning MRI altered CTV design, dose and/or duration of androgen deprivation in 18% of patients in this large, single institution series of men planned for dose-escalated prostate IMRT. This has substantial implications for radiotherapy target volumes and doses, as well as duration of androgen deprivation. Further research is required to investigate whether newer MRI techniques can simultaneously fulfill staging and radiotherapy contouring roles. © 2014 Wiley Publishing Asia Pty Ltd.

  9. Restricted Field IMRT Dramatically Enhances IMRT Planning for Mesothelioma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allen, Aaron M.; Schofield, Deborah; Hacker, Fred

    2007-12-01

    Purpose: To improve the target coverage and normal tissue sparing of intensity-modulated radiotherapy (IMRT) for mesothelioma after extrapleural pneumonectomy. Methods and Materials: Thirteen plans from patients previously treated with IMRT for mesothelioma were replanned using a restricted field technique. This technique was novel in two ways. It limited the entrance beams to 200{sup o} around the target and three to four beams per case had their field apertures restricted down to the level of the heart or liver to further limit the contralateral lung dose. New constraints were added that included a mean lung dose of <9.5 Gy and volumemore » receiving {>=}5 Gy of <55%. Results: In all cases, the planning target volume coverage was excellent, with an average of 97% coverage of the planning target volume by the target dose. No change was seen in the target coverage with the new technique. The heart, kidneys, and esophagus were all kept under tolerance in all cases. The average mean lung dose, volume receiving {>=}20 Gy, and volume receiving {>=}5 Gy with the new technique was 6.6 Gy, 3.0%, and 50.8%, respectively, compared with 13.8 Gy, 15%, and 90% with the previous technique (p < 0.0001 for all three comparisons). The maximal value for any case in the cohort was 8.0 Gy, 7.3%, and 57.5% for the mean lung dose, volume receiving {>=}20 Gy, and volume receiving {>=}5 Gy, respectively. Conclusion: Restricted field IMRT provides an improved method to deliver IMRT to a complex target after extrapleural pneumonectomy. An upcoming Phase I trial will provide validation of these results.« less

  10. SU-F-T-404: Dosimetric Advantages of Flattening Free Beams to Prone Accelerated Partial Breast Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Galavis, P; Barbee, D; Jozsef, G

    2016-06-15

    Purpose: Prone accelerated partial breast irradiation (APBI) results in dose reduction to the heart and lung. Flattening filter free beams (FFF) reduce out of field dose due to the reduced scatter from the removal of the flattening filter and reduce the buildup region. The aim of this work is to evaluate the dosimetric advantages of FFF beams to prone APBI target coverage and reduction in dose to organs at risk. Methods: Fifteen clinical prone APBI cases using flattened photon beams were retrospectively re-planned in Eclipse-TPS using FFF beams. FFF plans were designed to provide equivalent target coverage with similar hotspotsmore » using the same field arrangements, resulting in comparable target DVHs. Both plans were transferred to a prone breast phantom and delivered on Varian-Edge-Linac. GafChromic-film was placed in the coronal plane of the phantom, partially overlapping the treatment field and extending into OARs to compare dose profiles from both plans. Results: FFF plans were comparable to the clinical plans with maximum doses of (108.3±2.3)% and (109.2±2.4)% and mean doses of (104.5±1.0)% and (104.6±1.2)%, respectively. Similar mean dose doses to the heart and contralateral lungs were observed from both plans, whereas the mean dose to the contra-lateral breast was (2.79±1.18) cGy and (2.86±1.40) cGy for FFF and clinical plans respectively. However for both plans the error between calculated and measured doses at 4 cm from the field edge was 10%. Conclusion: The results showed that FFF beams in prone APBI provide dosimetrically equivalent target coverage and improved coverage in superficial target due to softer energy spectra. Film analysis showed that the TPS underestimates dose outside field edges for both cases. The FFF measured plans showed less dose outside the beam that might reduce the probability of secondary cancers in the contralateral breast.« less

  11. 29 CFR 801.3 - Coverage.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 3 2013-07-01 2013-07-01 false Coverage. 801.3 Section 801.3 Labor Regulations Relating to... POLYGRAPH PROTECTION ACT OF 1988 General § 801.3 Coverage. (a) The coverage of the Act extends to “any... coverage to be coextensive with the full scope of the Congressional power to regulate commerce. See, for...

  12. 29 CFR 801.3 - Coverage.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 3 2014-07-01 2014-07-01 false Coverage. 801.3 Section 801.3 Labor Regulations Relating to... POLYGRAPH PROTECTION ACT OF 1988 General § 801.3 Coverage. (a) The coverage of the Act extends to “any... coverage to be coextensive with the full scope of the Congressional power to regulate commerce. See, for...

  13. 29 CFR 801.3 - Coverage.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 3 2011-07-01 2011-07-01 false Coverage. 801.3 Section 801.3 Labor Regulations Relating to... POLYGRAPH PROTECTION ACT OF 1988 General § 801.3 Coverage. (a) The coverage of the Act extends to “any... coverage to be coextensive with the full scope of the Congressional power to regulate commerce. See, for...

  14. Dosimetric accuracy of a treatment planning system for actively scanned proton beams and small target volumes: Monte Carlo and experimental validation

    NASA Astrophysics Data System (ADS)

    Magro, G.; Molinelli, S.; Mairani, A.; Mirandola, A.; Panizza, D.; Russo, S.; Ferrari, A.; Valvo, F.; Fossati, P.; Ciocca, M.

    2015-09-01

    This study was performed to evaluate the accuracy of a commercial treatment planning system (TPS), in optimising proton pencil beam dose distributions for small targets of different sizes (5-30 mm side) located at increasing depths in water. The TPS analytical algorithm was benchmarked against experimental data and the FLUKA Monte Carlo (MC) code, previously validated for the selected beam-line. We tested the Siemens syngo® TPS plan optimisation module for water cubes fixing the configurable parameters at clinical standards, with homogeneous target coverage to a 2 Gy (RBE) dose prescription as unique goal. Plans were delivered and the dose at each volume centre was measured in water with a calibrated PTW Advanced Markus® chamber. An EBT3® film was also positioned at the phantom entrance window for the acquisition of 2D dose maps. Discrepancies between TPS calculated and MC simulated values were mainly due to the different lateral spread modeling and resulted in being related to the field-to-spot size ratio. The accuracy of the TPS was proved to be clinically acceptable in all cases but very small and shallow volumes. In this contest, the use of MC to validate TPS results proved to be a reliable procedure for pre-treatment plan verification.

  15. Dosimetric accuracy of a treatment planning system for actively scanned proton beams and small target volumes: Monte Carlo and experimental validation.

    PubMed

    Magro, G; Molinelli, S; Mairani, A; Mirandola, A; Panizza, D; Russo, S; Ferrari, A; Valvo, F; Fossati, P; Ciocca, M

    2015-09-07

    This study was performed to evaluate the accuracy of a commercial treatment planning system (TPS), in optimising proton pencil beam dose distributions for small targets of different sizes (5-30 mm side) located at increasing depths in water. The TPS analytical algorithm was benchmarked against experimental data and the FLUKA Monte Carlo (MC) code, previously validated for the selected beam-line. We tested the Siemens syngo(®) TPS plan optimisation module for water cubes fixing the configurable parameters at clinical standards, with homogeneous target coverage to a 2 Gy (RBE) dose prescription as unique goal. Plans were delivered and the dose at each volume centre was measured in water with a calibrated PTW Advanced Markus(®) chamber. An EBT3(®) film was also positioned at the phantom entrance window for the acquisition of 2D dose maps. Discrepancies between TPS calculated and MC simulated values were mainly due to the different lateral spread modeling and resulted in being related to the field-to-spot size ratio. The accuracy of the TPS was proved to be clinically acceptable in all cases but very small and shallow volumes. In this contest, the use of MC to validate TPS results proved to be a reliable procedure for pre-treatment plan verification.

  16. An assessment of mumps vaccine effectiveness by dose during an outbreak in Canada

    PubMed Central

    Deeks, Shelley L.; Lim, Gillian H.; Simpson, Mary Anne; Gagné, Louise; Gubbay, Jonathan; Kristjanson, Erik; Fung, Cecilia; Crowcroft, Natasha S.

    2011-01-01

    Background This investigation was done to assess vaccine effectiveness of one and two doses of the measles, mumps and rubella (MMR) vaccine during an outbreak of mumps in Ontario. The level of coverage required to reach herd immunity and interrupt community transmission of mumps was also estimated. Methods Information on confirmed cases of mumps was retrieved from Ontario’s integrated Public Health Information System. Cases that occurred between Sept. 1, 2009, and June 10, 2010, were included. Selected health units supplied coverage data from the Ontario Immunization Record Information System. Vaccine effectiveness by dose was calculated using the screening method. The basic reproductive number (R0) represents the average number of new infections per case in a fully susceptile population, and R0 values of between 4 and 10 were considered for varying levels of vaccine effectiveness. Results A total of 134 confirmed cases of mumps were identified. Information on receipt of MMR vaccine was available for 114 (85.1%) cases, of whom 63 (55.3%) reported having received only one dose of vaccine; 32 (28.1%) reported having received two doses. Vaccine effectiveness of one dose of the MMR vaccine ranged from 49.2% to 81.6%, whereas vaccine effectiveness of two doses ranged from 66.3% to 88.0%. If we assume vaccine effectiveness of 85% for two doses of the vaccine, vaccine coverage of 88.2% and 98.0% would be needed to interrupt community transmission of mumps if the corresponding reproductive values were four and six. Interpretation Our estimates of vaccine effectiveness of one and two doses of mumps-containing vaccine were consistent with the estimates that have been reported in other outbreaks. Outbreaks occurring in Ontario and elsewhere serve as a warning against complacency over vaccination programs. PMID:21576295

  17. An assessment of mumps vaccine effectiveness by dose during an outbreak in Canada.

    PubMed

    Deeks, Shelley L; Lim, Gillian H; Simpson, Mary Anne; Gagné, Louise; Gubbay, Jonathan; Kristjanson, Erik; Fung, Cecilia; Crowcroft, Natasha S

    2011-06-14

    This investigation was done to assess vaccine effectiveness of one and two doses of the measles, mumps and rubella (MMR) vaccine during an outbreak of mumps in Ontario. The level of coverage required to reach herd immunity and interrupt community transmission of mumps was also estimated. Information on confirmed cases of mumps was retrieved from Ontario's integrated Public Health Information System. Cases that occurred between Sept. 1, 2009, and June 10, 2010, were included. Selected health units supplied coverage data from the Ontario Immunization Record Information System. Vaccine effectiveness by dose was calculated using the screening method. The basic reproductive number (R(0)) represents the average number of new infections per case in a fully susceptible population, and R(0) values of between 4 and 10 were considered for varying levels of vaccine effectiveness. A total of 134 confirmed cases of mumps were identified. Information on receipt of MMR vaccine was available for 114 (85.1%) cases, of whom 63 (55.3%) reported having received only one dose of vaccine; 32 (28.1%) reported having received two doses. Vaccine effectiveness of one dose of the MMR vaccine ranged from 49.2% to 81.6%, whereas vaccine effectiveness of two doses ranged from 66.3% to 88.0%. If we assume vaccine effectiveness of 85% for two doses of the vaccine, vaccine coverage of 88.2% and 98.0% would be needed to interrupt community transmission of mumps if the corresponding reproductive values were four and six. Our estimates of vaccine effectiveness of one and two doses of mumps-containing vaccine were consistent with the estimates that have been reported in other outbreaks. Outbreaks occurring in Ontario and elsewhere serve as a warning against complacency over vaccination programs.

  18. SU-F-T-380: Comparing the Effect of Respiration On Dose Distribution Between Conventional Tangent Pair and IMRT Techniques for Adjuvant Radiotherapy in Early Stage Breast Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, M; Ramaseshan, R

    2016-06-15

    Purpose: In this project, we compared the conventional tangent pair technique to IMRT technique by analyzing the dose distribution. We also investigated the effect of respiration on planning target volume (PTV) dose coverage in both techniques. Methods: In order to implement IMRT technique a template based planning protocol, dose constrains and treatment process was developed. Two open fields with optimized field weights were combined with two beamlet optimization fields in IMRT plans. We compared the dose distribution between standard tangential pair and IMRT. The improvement in dose distribution was measured by parameters such as conformity index, homogeneity index and coveragemore » index. Another end point was the IMRT technique will reduce the planning time for staff. The effect of patient’s respiration on dose distribution was also estimated. The four dimensional computed tomography (4DCT) for different phase of breathing cycle was used to evaluate the effect of respiration on IMRT planned dose distribution. Results: We have accumulated 10 patients that acquired 4DCT and planned by both techniques. Based on the preliminary analysis, the dose distribution in IMRT technique was better than conventional tangent pair technique. Furthermore, the effect of respiration in IMRT plan was not significant as evident from the 95% isodose line coverage of PTV drawn on all phases of 4DCT. Conclusion: Based on the 4DCT images, the breathing effect on dose distribution was smaller than what we expected. We suspect that there are two reasons. First, the PTV movement due to respiration was not significant. It might be because we used a tilted breast board to setup patients. Second, the open fields with optimized field weights in IMRT technique might reduce the breathing effect on dose distribution. A further investigation is necessary.« less

  19. The impact of new vaccine introduction on the coverage of existing vaccines: a cross-national, multivariable analysis.

    PubMed

    Shearer, Jessica C; Walker, Damian G; Risko, Nicholas; Levine, Orin S

    2012-12-14

    A surge of new and underutilized vaccine introductions into national immunization programmes has called into question the effect of new vaccine introduction on immunization and health systems. In particular, countries deciding whether to introduce a new or underutilized vaccine into their routine immunization programme may query possible effects on the delivery and coverage of existing vaccines. Using coverage of diphtheria-tetanus-pertussis (DTP) vaccine as a proxy for immunization system performance, this study aims to test whether new vaccine introduction into national immunization programs was associated with changes in coverage of three doses of DTP vaccine among infants. DTP3 vaccine coverage was analyzed in 187 countries during 1999-2009 using multivariable cross-national mixed-effect longitudinal models. Controlling for other possible determinants of DTP3 coverage at the national level these models found minimal association between the introduction of Hepatitis-, Haemophilus influenzae type b-, and rotavirus-containing vaccines and DTP3 coverage. Instead, frequent and sometimes large fluctuations in coverage are associated with other development and health systems variables, including the presence of armed conflict, coverage of antenatal care services, infant mortality, the percent of health expenditures that are private and total health expenditures per capita. Introductions of new vaccines did not affect national coverage of DTP3 vaccine in the countries studied. Introductions of other new vaccines and multiple vaccine introductions should be monitored for immunization and health systems impacts. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. SU-E-T-287: Dose Verification On the Variation of Target Volume and Organ at Risk in Preradiation Chemotherapy IMRT for Nasopharyngeal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, X; Kong, L; Wang, J

    2015-06-15

    Purpose: To quantify the target volume and organ at risk of nasopharyngeal carcinoma (NPC) patients with preradiation chemotherapy based on CT scanned during intensity-modulated radiotherapy (IMRT), and recalculate the dose distribution. Methods: Seven patients with NPC and preradiation chemotherapy, treated with IMRT (35 to 37 fractions) were reviewed. Repeat CT scanning was required to all of the patients during the radiotherapy, and the number of repeat CTs varies from 2 to 6. The plan CT and repeat CT were generated by different CT scanner. To ensure crespectively on the same IMPT plan. The real dose distribution was calculated by deformablemore » registration and weighted method in Raystation (v 4.5.1). The fraction of each dose is based on radiotherapy record. The volumetric and dose differences among these images were calculated for nascIpharyngeal tumor and retro-pharyngeal lymph nodes (GTV-NX), neck lymph nodes(GTV-ND), and parotid glands. Results: The volume variation in GTV-NX from CT1 to CT2 was 1.15±3.79%, and in GTV-LN −0.23±4.93%. The volume variation in left parotid from CT1 to CT2 was −6.79±11.91%, and in right parotid −3.92±8.80%. In patient 2, the left parotid volume were decreased remarkably, as a Result, the V30 and V40 of it were increased as well. Conclusion: The target volume of patients with NPC varied lightly during IMRT. It shows that preradiation chemotherapy can control the target volume variation and perform a good dose repeatability. Also, the decreasing volume of parotid in some patient might increase the dose of it, which might course potential complications.« less

  1. SU-F-T-314: Estimation of Dose Distributions with Different Types of Breast Implants in Various Radiation Treatment Techniques for Breast Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, M; Lee, S; Suh, T

    Purpose: This study investigates the effects of different kinds and designs of commercialized breast implants on the dose distributions in breast cancer radiotherapy under a variety of conditions. Methods: The dose for the clinical conventional tangential irradiation, Intensity Modulated Radiation Therapy (IMRT), volumetric modulated arc therapy (VMAT) breast plans was measured using radiochromic films and stimulated luminescence dosimeter (OSLD). The radiochromic film was used as an integrating dosimeter, while the OSLDs were used for real-time dosimetry to isolate the contribution of dose from individual segment. The films were placed at various slices in the Rando phantom and between the bodymore » and breast surface OSLDs were used to measure skin dose at 18 positions spaced on the two (right/left) breast. The implant breast was placed on the left side and the phantom breast was remained on the right side. Each treatment technique was performed on different size of the breasts and different shape of the breast implant. The PTV dose was prescribed 50.4 Gy and V47.88≥95%. Results: In different shapes of the breast implant, because of the shadow formed extensive around the breast implant, dose variation was relatively higher that of prescribed dose. As the PTV was delineated on the whole breast, maximum 5% dose error and average 3% difference was observed averagely. VMAT techniques largely decrease the contiguous hot spot in the skin by an average of 25% compared with IMRT. The both IMRT and VMAT techniques resulted in lower doses to normal critical structures than tangential plans for nearly all dose analyzation. Conclusion: Compared to the other technique, IMRT reduced radiation dose exposure to normal tissues and maintained reasonable target homogeneity and for the same target coverage, VMAT can reduce the skin dose in all the regions of the body.« less

  2. Coverage and predictors of vaccination against 2012/13 seasonal influenza in Madrid, Spain

    PubMed Central

    Jiménez-García, Rodrigo; Esteban-Vasallo, María D; Rodríguez-Rieiro, Cristina; Hernandez-Barrera, Valentín; Domínguez-Berjón, MA Felicitas; Carrasco Garrido, Pilar; Lopez de Andres, Ana; Cameno Heras, Moises; Iniesta Fornies, Domingo; Astray-Mochales, Jenaro

    2014-01-01

    We aim to determine 2012–13 seasonal influenza vaccination coverage. Data were analyzed by age group and by coexistence of concomitant chronic conditions. Factors associated with vaccine uptake were identified. We also analyze a possible trend in vaccine uptake in post pandemic seasons. We used computerized immunization registries and clinical records of the entire population of the Autonomous Community of Madrid, Spain (6 284 128 persons) as data source. A total of 871 631 individuals were vaccinated (13.87%). Coverage for people aged ≥ 65 years was 56.57%. Global coverage in people with a chronic condition was 15.7% in children and 18.69% in adults aged 15–59 years. The variables significantly associated with a higher likelihood of being vaccinated in the 2012–13 campaign for the age groups studied were higher age, being Spanish-born, higher number of doses of seasonal vaccine received in previous campaigns, uptake of pandemic vaccination, and having a chronic condition. We conclude that vaccination coverage in persons aged <60 years with chronic conditions is less than acceptable. The very low coverage among children with chronic conditions calls for urgent interventions. Among those aged ≥60 years, uptake is higher but still far from optimal and seems to be descending in post-pandemic campaigns. For those aged ≥65 years the mean percentage of decrease from the 2009/10 to the actual campaign has been 12%. Computerized clinical and immunization registers are useful tools for providing rapid and detailed information about influenza vaccination coverage in the population. PMID:24280728

  3. Vitamin A supplementation in Tanzania: the impact of a change in programmatic delivery strategy on coverage.

    PubMed

    Masanja, Honorati; Schellenberg, Joanna Armstrong; Mshinda, Hassan M; Shekar, Meera; Mugyabuso, Joseph K L; Ndossi, Godwin D; de Savigny, Don

    2006-11-01

    Efficient delivery strategies for health interventions are essential for high and sustainable coverage. We report impact of a change in programmatic delivery strategy from routine delivery through the Expanded Programme on Immunization (EPI+) approach to twice-yearly mass distribution campaigns on coverage of vitamin A supplementation in Tanzania We investigated disparities in age, sex, socio-economic status, nutritional status and maternal education within vitamin A coverage in children between 1 and 2 years of age from two independent household level child health surveys conducted (1) during a continuous universal targeting scheme based on routine EPI contacts for children aged 9, 15 and 21 months (1999); and (2) three years later after the introduction of twice-yearly vitamin A supplementation campaigns for children aged 6 months to 5 years, a 6-monthly universal targeting scheme (2002). A representative cluster sample of approximately 2,400 rural households was obtained from Rufiji, Morogoro Rural, Kilombero and Ulanga districts. A modular questionnaire about the health of all children under the age of five was administered to consenting heads of households and caretakers of children. Information on the use of child health interventions including vitamin A was asked. Coverage of vitamin A supplementation among 1-2 year old children increased from 13% [95% CI 10-18%] in 1999 to 76% [95%CI 72-81%] in 2002. In 2002 knowledge of two or more child health danger signs was negatively associated with vitamin A supplementation coverage (80% versus 70%) (p = 0.04). Nevertheless, we did not find any disparities in coverage of vitamin A by district, gender, socio-economic status and DPT vaccinations. Change in programmatic delivery of vitamin A supplementation was associated with a major improvement in coverage in Tanzania that was been sustained by repeated campaigns for at least three years. There is a need to monitor the effect of such campaigns on the routine health

  4. Annual immunisation coverage report, 2010.

    PubMed

    Hull, Brynley; Dey, Aditi; Menzies, Rob; McIntyre, Peter

    2013-03-31

    This, the fourth annual immunisation coverage report, documents trends during 2010 for a range of standard measures derived from Australian Childhood Immunisation Register (ACIR) data. These include coverage at standard age milestones and for individual vaccines included on the National Immunisation Program (NIP). For the first time, coverage from other sources for adolescents and the elderly are included. The proportion of children 'fully vaccinated' at 12, 24 and 60 months of age was 91.6%, 92.1% and 89.1% respectively. For vaccines available on the NIP but not currently assessed for 'fully immunised' status or for eligibility for incentive payments (rotavirus and pneumococcal at 12 months and meningococcal C and varicella at 24 months) coverage varied. Although pneumococcal vaccine had similar coverage at 12 months to other vaccines, coverage was lower for rotavirus at 12 months (84.7%) and varicella at 24 months (83.0%). Overall coverage at 24 months of age exceeded that at 12 months of age nationally and for most jurisdictions, but as receipt of varicella vaccine at 18 months is excluded from calculations, this represents delayed immunisation, with some contribution from immunisation incentives. The 'fully immunised' coverage estimates for immunisations due by 60 months increased substantially in 2009, reaching almost 90% in 2010, probably related to completed immunisation by 60 months of age being introduced in 2009 as a requirement for GP incentive payments. As previously documented, vaccines recommended for Indigenous children only (hepatitis A and pneumococcal polysaccharide vaccine) had suboptimal coverage at around 57%. Delayed receipt of vaccines by Indigenous children at the 60-month milestone age improved from 56% to 62% but the disparity in on-time vaccination between Indigenous and non-Indigenous children at earlier age milestones did not improve. Coverage data for human papillomavirus (HPV)from the national HPV register are consistent with high

  5. Horses for Courses: Moving India towards Universal Health Coverage through Targeted Policy Design.

    PubMed

    Maurya, Dayashankar; Virani, Altaf; Rajasulochana, S

    2017-12-01

    The debate on how India's health system should move towards universal health coverage was (meant to be) put to rest by the recent National Health Policy 2017. However, the new policy is silent about tackling bottlenecks mentioned in the said policy proposal. It aims to provide universal access to free primary care by strengthening the public system, and to secondary and tertiary care through strategic purchasing from the private sector, to overcome deficiencies in public provisioning in the short run. Yet, in doing so, it ignores critical factors needed to replicate successful models of public healthcare delivery from certain states that it hopes to emulate. The policy also overestimates the capacity of the public sector and downplays the challenges observed in purchasing secondary care. Drawing from literature in policy design, we emphasize that primary, secondary and tertiary care have distinct characteristics, and their provision requires separate approaches or policy tools depending on the context. Public provisioning, contract purchasing and insurance mechanisms are different policy tools that have to be matched with the context and characteristics of the policy arena. Given the current challenges of India's health system, we argue that tertiary care services are most suitable for insurance-based purchasing, while the public sector should concentrate on building the required capacities to dominate the provisioning of secondary care and fill gaps in primary care delivery, for India to achieve its universal coverage ambitions.

  6. Overview of Global, Regional, and National Routine Vaccination Coverage Trends and Growth Patterns From 1980 to 2009: Implications for Vaccine-Preventable Disease Eradication and Elimination Initiatives

    PubMed Central

    Wallace, Aaron S.; Ryman, Tove K.; Dietz, Vance

    2015-01-01

    Background Review of the historical growth in annual vaccination coverage across countries and regions can better inform decision makers’ development of future goals and strategies to improve routine vaccination services. Methods Using the World Health Organization (WHO) and the United Nations Children's Fund estimates of annual national third dose of diphtheria-tetanus-pertussis–containing vaccine (DTP3) and third dose of polio vaccine (POL3) coverage for 1980–2009, we calculated the mean absolute annual rate of change in national DTP3 coverage among all countries (globally) and among countries within each WHO region, as well as the number of years taken by each region to reach specific regional coverage levels. Last, we assessed differences in mean absolute annual rate of change in DTP3 coverage, stratified by baseline level of DTP3 coverage. Results During the 1980s, global DTP3 coverage increased a mean of 5.3 percentage points/year. Annual rate of change decreased to 0.5 percentage points/year in the 1990s and then increased to 0.9 percentage points/year during the 2000s. Mean annual rate of change in coverage across all countries was highest (9.2 percentage points) when national coverage levels were 26%–30% and lowest (−0.9 percentage points) when national coverage levels were 96%–100%. Regional differences existed as both WHO South-East Asia Region and WHO African Region countries experienced mean negative DTP3 coverage growth at lower coverage levels (81%–85%) than other regions. The regions that have achieved 95% DTP3 coverage (Americas, Western Pacific, and European) took 25–29 years to reach that level from a level of 50% DTP3 coverage. POL3 coverage change trends were similar to described DTP3 coverage change trends. Conclusions Mean national coverage growth patterns across all regions are nonlinear as coverage levels increase. Saturation points of mean 0 percentage-point growth in annual coverage varies by region and require further

  7. NEW DEVELOPMENTS IN RADIATION THERAPY FOR HEAD AND NECK CANCER: INTENSITY MODULATED RADIATION THERAPY AND HYPOXIA TARGETING

    PubMed Central

    Lee, Nancy Y.; Le, Quynh-Thu

    2008-01-01

    Intensity modulated radiation therapy (IMRT) has revolutionized radiation treatment for head and neck cancers (HNC). When compared to the traditional techniques, IMRT has the unique ability to minimize the dose delivered to normal tissues without compromising tumor coverage. As a result, side effects from high dose radiation have decreased and patient quality of life has improved. In addition to toxicity reduction, excellent clinical outcomes have been reported for IMRT. The first part of this review will focus on clinical results of IMRT for HNC. Tumor hypoxia or the condition of low oxygen is a key factor for tumor progression and treatment resistance. Hypoxia develops in solid tumors due to aberrant blood vessel formation, fluctuation in blood flow and increasing oxygen demands for tumor growth. Because hypoxic tumor cells are more resistant to ionizing radiation, hypoxia has been a focus of clinical research in radiation therapy for half a decade. Interest for targeting tumor hypoxia have waxed and waned as promising treatments emerged from the laboratory, only to fail in the clinics. However, with the development of new technologies, the prospect of targeting tumor hypoxia is more tangible. The second half of the review will focus on approaches for assessing tumor hypoxia and on the strategies for targeting this important microenvironmental factor in HNC. PMID:18544439

  8. Clustered lot quality assurance sampling: a pragmatic tool for timely assessment of vaccination coverage.

    PubMed

    Greenland, K; Rondy, M; Chevez, A; Sadozai, N; Gasasira, A; Abanida, E A; Pate, M A; Ronveaux, O; Okayasu, H; Pedalino, B; Pezzoli, L

    2011-07-01

    To evaluate oral poliovirus vaccine (OPV) coverage of the November 2009 round in five Northern Nigeria states with ongoing wild poliovirus transmission using clustered lot quality assurance sampling (CLQAS). We selected four local government areas in each pre-selected state and sampled six clusters of 10 children in each Local Government Area, defined as the lot area. We used three decision thresholds to classify OPV coverage: 75-90%, 55-70% and 35-50%. A full lot was completed, but we also assessed in retrospect the potential time-saving benefits of stopping sampling when a lot had been classified. We accepted two local government areas (LGAs) with vaccination coverage above 75%. Of the remaining 18 rejected LGAs, 11 also failed to reach 70% coverage, of which four also failed to reach 50%. The average time taken to complete a lot was 10 h. By stopping sampling when a decision was reached, we could have classified lots in 5.3, 7.7 and 7.3 h on average at the 90%, 70% and 50% coverage targets, respectively. Clustered lot quality assurance sampling was feasible and useful to estimate OPV coverage in Northern Nigeria. The multi-threshold approach provided useful information on the variation of IPD vaccination coverage. CLQAS is a very timely tool, allowing corrective actions to be directly taken in insufficiently covered areas. © 2011 Blackwell Publishing Ltd.

  9. 7 CFR 1437.5 - Coverage period.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 10 2013-01-01 2013-01-01 false Coverage period. 1437.5 Section 1437.5 Agriculture... Provisions § 1437.5 Coverage period. (a) The coverage period is the time during which coverage is available against loss of production of the eligible crop as a result of natural disaster. (b) The coverage period...

  10. Did the dependent coverage expansion increase risky substance use among young adults?

    PubMed

    Breslau, Joshua; Yu, Hao; Han, Bing; Pacula, Rosalie L; Burns, Rachel M; Stein, Bradley D

    2017-09-01

    The dependent coverage expansion (DCE) enacted through the Affordable Care Act increased health insurance coverage among young adults. Increasing insurance coverage in this age group has the potential for unintended consequences on risky substance use. Repeated cross-sectional surveys were used to compare change in substance use during the period the DCE was implemented in the 19-25year old target age group (Pre-DCE n=15,772, Post-DCE n=22,719) with contemporaneous change in a slightly older age group that was not targeted by the policy (Pre-DCE=19,851, Post-DCE n=28,157). Outcomes include 11 measures of alcohol, illicit drug and cigarette use. Statistical controls were included for demographic and socioeconomic factors and for early initiation of substance use to adjust for historical trends in developmental trajectories. Risky substance use decreased in young adults relative to the older age group over the period that the DCE was implemented. However, statistical adjustment for initiation of substance use prior to age 18, which is prior to exposure to the DCE, accounted for the differences between the age groups. In adjusted models, associations between the DCE and substance use outcomes range from 0.96 to 1.08 with p-values ranging from 0.330 to 0.963. Historical trends in initiation of substance use prior to age 18, not the DCE, account for change in risky substance use among 19-25year olds relative to 26-34year olds. The evidence does not support the suggestion that health insurance coverage would increase risky substance use among young adults. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Is there a correlation between malaria incidence and IRS coverage in western Zambezi region, Namibia?

    PubMed Central

    Sturrock, H.; Hsiang, M.; Roberts, K.; Kleinschmidt, I.; Nghipumbwa, M.; Uusiku, P.; Smith, J.; Bennet, A.; Kizito, W.; Takarinda, K.; Ade, S.; Gosling, R.

    2018-01-01

    Setting: A comparison of routine Namibia National Malaria Programme data (reported) vs. household survey data (administrative) on indoor residual spraying (IRS) in western Zambezi region, Namibia, for the 2014–2015 malaria season. Objectives: To determine 1) IRS coverage (administrative and reported), 2) its effect on malaria incidence, and 3) reasons for non-uptake of IRS in western Zambezi region, Namibia, for the 2014–2015 malaria season. Design: This was a descriptive study. Results: IRS coverage in western Zambezi region was low, ranging from 42.3% to 52.2% for administrative coverage vs. 45.9–66.7% for reported coverage. There was no significant correlation between IRS coverage and malaria incidence for this region (r = −0.45, P = 0.22). The main reasons for households not being sprayed were that residents were not at home during spraying times or that spray operators did not visit the households. Conclusions: IRS coverage in western Zambezi region, Namibia, was low during the 2014–2015 malaria season because of poor community engagement and awareness of times for spray operations within communities. Higher IRS coverage could be achieved through improved community engagement. Better targeting of the highest risk areas by the use of malaria surveillance will be required to mitigate malaria transmission. PMID:29713594

  12. Is there a correlation between malaria incidence and IRS coverage in western Zambezi region, Namibia?

    PubMed

    Mumbengegwi, D R; Sturrock, H; Hsiang, M; Roberts, K; Kleinschmidt, I; Nghipumbwa, M; Uusiku, P; Smith, J; Bennet, A; Kizito, W; Takarinda, K; Ade, S; Gosling, R

    2018-04-25

    Setting: A comparison of routine Namibia National Malaria Programme data (reported) vs. household survey data (administrative) on indoor residual spraying (IRS) in western Zambezi region, Namibia, for the 2014-2015 malaria season. Objectives: To determine 1) IRS coverage (administrative and reported), 2) its effect on malaria incidence, and 3) reasons for non-uptake of IRS in western Zambezi region, Namibia, for the 2014-2015 malaria season. Design: This was a descriptive study. Results: IRS coverage in western Zambezi region was low, ranging from 42.3% to 52.2% for administrative coverage vs. 45.9-66.7% for reported coverage. There was no significant correlation between IRS coverage and malaria incidence for this region ( r = -0.45, P = 0.22). The main reasons for households not being sprayed were that residents were not at home during spraying times or that spray operators did not visit the households. Conclusions: IRS coverage in western Zambezi region, Namibia, was low during the 2014-2015 malaria season because of poor community engagement and awareness of times for spray operations within communities. Higher IRS coverage could be achieved through improved community engagement. Better targeting of the highest risk areas by the use of malaria surveillance will be required to mitigate malaria transmission.

  13. Pesticide Dose - A Parameter with Many Implications

    USDA-ARS?s Scientific Manuscript database

    Like pharmaceuticals, pesticides can have unintended effects, even when used at the proper dose. For pesticides, the possible effects are even more diverse, because the chemicals are released immediately into the environment and the dose reaching the intended target(s) and unintended targets can var...

  14. Moderate-dose sedation and analgesia during targeted temperature management after cardiac arrest.

    PubMed

    May, Teresa L; Seder, David B; Fraser, Gilles L; Stone, Philip; McCrum, Barbara; Riker, Richard R

    2015-02-01

    Sedation and analgesia regimens during targeted temperature management (TTM), after cardiac arrest varies widely, are poorly described in the literature and may have a negative impact on outcome. Since implementing TTM in 2005, we have used moderate-dose sedation and describe our experience with this approach. In this retrospective review, we included patients treated with TTM for cardiac arrest at our institution for 2008-2012. Patients received TTM if they did not follow verbal commands following cardiac arrest, regardless of place of arrest or rhythm. Utstein-compatible data were prospectively entered into the International Cardiac Arrest Registry, supplemented by review of nursing, pharmacy, and physical therapy records. We report analgesic and sedative medications and doses during the 24 h of active TTM at 33 °C, resource utilization, and important clinical events. 166 patients treated with TTM after in- and out-of-hospital cardiac arrest with complete data were included. Overall survival was 42 %, median time to following commands was 3 h after rewarming (-6, 14), time to spontaneous breathing trial was 19 h (5-35), time to extubation was 28 h (9-60), and 59 % of survivors were discharged directly home at 13 (10-20) days. The incidence of seizure was 6 %, septic shock 4 %, and pneumonia 32 %. Four survivors required tracheostomy at 8, 8, 12, and 16 days. A moderate-dose sedation and analgesia regimen was well tolerated and effective during therapeutic hypothermia after cardiac arrest and is an effective alternative to very deep sedation. We recommend more complete description of sedation and analgesia protocols in future studies, including expanded outcome reporting to include variables affected by sedation therapy. Further study is required to define which sedation approach for TTM may be best.

  15. A Dosimetric Comparison of Breast Radiotherapy Techniques to Treat Locoregional Lymph Nodes Including the Internal Mammary Chain.

    PubMed

    Ranger, A; Dunlop, A; Hutchinson, K; Convery, H; Maclennan, M K; Chantler, H; Twyman, N; Rose, C; McQuaid, D; Amos, R A; Griffin, C; deSouza, N M; Donovan, E; Harris, E; Coles, C E; Kirby, A

    2018-06-01

    Radiotherapy target volumes in early breast cancer treatment increasingly include the internal mammary chain (IMC). In order to maximise survival benefits of IMC radiotherapy, doses to the heart and lung should be minimised. This dosimetry study compared the ability of three-dimensional conformal radiotherapy, arc therapy and proton beam therapy (PBT) techniques with and without breath-hold to achieve target volume constraints while minimising dose to organs at risk (OARs). In 14 patients' datasets, seven IMC radiotherapy techniques were compared: wide tangent (WT) three-dimensional conformal radiotherapy, volumetric-modulated arc therapy (VMAT) and PBT, each in voluntary deep inspiratory breath-hold (vDIBH) and free breathing (FB), and tomotherapy in FB only. Target volume coverage and OAR doses were measured for each technique. These were compared using a one-way ANOVA with all pairwise comparisons tested using Bonferroni's multiple comparisons test, with adjusted P-values ≤ 0.05 indicating statistical significance. One hundred per cent of WT(vDIBH), 43% of WT(FB), 100% of VMAT(vDIBH), 86% of VMAT(FB), 100% of tomotherapy FB and 100% of PBT plans in vDIBH and FB passed all mandatory constraints. However, coverage of the IMC with 90% of the prescribed dose was significantly better than all other techniques using VMAT(vDIBH), PBT(vDIBH) and PBT(FB) (mean IMC coverage ± 1 standard deviation = 96.0% ± 4.3, 99.8% ± 0.3 and 99.0% ± 0.2, respectively). The mean heart dose was significantly reduced in vDIBH compared with FB for both the WT (P < 0.0001) and VMAT (P < 0.0001) techniques. There was no advantage in target volume coverage or OAR doses for PBT(vDIBH) compared with PBT(FB). Simple WT radiotherapy delivered in vDIBH achieves satisfactory coverage of the IMC while meeting heart and lung dose constraints. However, where higher isodose coverage is required, VMAT(vDIBH) is the optimal photon technique. The lowest OAR doses are achieved by PBT

  16. A Novel Energy Efficient Topology Control Scheme Based on a Coverage-Preserving and Sleep Scheduling Model for Sensor Networks.

    PubMed

    Shi, Binbin; Wei, Wei; Wang, Yihuai; Shu, Wanneng

    2016-10-14

    In high-density sensor networks, scheduling some sensor nodes to be in the sleep mode while other sensor nodes remain active for monitoring or forwarding packets is an effective control scheme to conserve energy. In this paper, a Coverage-Preserving Control Scheduling Scheme (CPCSS) based on a cloud model and redundancy degree in sensor networks is proposed. Firstly, the normal cloud model is adopted for calculating the similarity degree between the sensor nodes in terms of their historical data, and then all nodes in each grid of the target area can be classified into several categories. Secondly, the redundancy degree of a node is calculated according to its sensing area being covered by the neighboring sensors. Finally, a centralized approximation algorithm based on the partition of the target area is designed to obtain the approximate minimum set of nodes, which can retain the sufficient coverage of the target region and ensure the connectivity of the network at the same time. The simulation results show that the proposed CPCSS can balance the energy consumption and optimize the coverage performance of the sensor network.

  17. A combination of low-dose bevacizumab and imatinib enhances vascular normalisation without inducing extracellular matrix deposition.

    PubMed

    Schiffmann, L M; Brunold, M; Liwschitz, M; Goede, V; Loges, S; Wroblewski, M; Quaas, A; Alakus, H; Stippel, D; Bruns, C J; Hallek, M; Kashkar, H; Hacker, U T; Coutelle, O

    2017-02-28

    Vascular endothelial growth factor (VEGF)-targeting drugs normalise the tumour vasculature and improve access for chemotherapy. However, excessive VEGF inhibition fails to improve clinical outcome, and successive treatment cycles lead to incremental extracellular matrix (ECM) deposition, which limits perfusion and drug delivery. We show here, that low-dose VEGF inhibition augmented with PDGF-R inhibition leads to superior vascular normalisation without incremental ECM deposition thus maintaining access for therapy. Collagen IV expression was analysed in response to VEGF inhibition in liver metastasis of colorectal cancer (CRC) patients, in syngeneic (Panc02) and xenograft tumours of human colorectal cancer cells (LS174T). The xenograft tumours were treated with low (0.5 mg kg -1 body weight) or high (5 mg kg -1 body weight) doses of the anti-VEGF antibody bevacizumab with or without the tyrosine kinase inhibitor imatinib. Changes in tumour growth, and vascular parameters, including microvessel density, pericyte coverage, leakiness, hypoxia, perfusion, fraction of vessels with an open lumen, and type IV collagen deposition were compared. ECM deposition was increased after standard VEGF inhibition in patients and tumour models. In contrast, treatment with low-dose bevacizumab and imatinib produced similar growth inhibition without inducing detrimental collagen IV deposition, leading to superior vascular normalisation, reduced leakiness, improved oxygenation, more open vessels that permit perfusion and access for therapy. Low-dose bevacizumab augmented by imatinib selects a mature, highly normalised and well perfused tumour vasculature without inducing incremental ECM deposition that normally limits the effectiveness of VEGF targeting drugs.

  18. Recommendation system for immunization coverage and monitoring.

    PubMed

    Bhatti, Uzair Aslam; Huang, Mengxing; Wang, Hao; Zhang, Yu; Mehmood, Anum; Di, Wu

    2018-01-02

    Immunization averts an expected 2 to 3 million deaths every year from diphtheria, tetanus, pertussis (whooping cough), and measles; however, an additional 1.5 million deaths could be avoided if vaccination coverage was improved worldwide. 1 1 Data source for immunization records of 1.5 M: http://www.who.int/mediacentre/factsheets/fs378/en/ New vaccination technologies provide earlier diagnoses, personalized treatments and a wide range of other benefits for both patients and health care professionals. Childhood diseases that were commonplace less than a generation ago have become rare because of vaccines. However, 100% vaccination coverage is still the target to avoid further mortality. Governments have launched special campaigns to create an awareness of vaccination. In this paper, we have focused on data mining algorithms for big data using a collaborative approach for vaccination datasets to resolve problems with planning vaccinations in children, stocking vaccines, and tracking and monitoring non-vaccinated children appropriately. Geographical mapping of vaccination records helps to tackle red zone areas, where vaccination rates are poor, while green zone areas, where vaccination rates are good, can be monitored to enable health care staff to plan the administration of vaccines. Our recommendation algorithm assists in these processes by using deep data mining and by accessing records of other hospitals to highlight locations with lower rates of vaccination. The overall performance of the model is good. The model has been implemented in hospitals to control vaccination across the coverage area.

  19. The influence of non-DNA-targeted effects on carbon ion–induced low-dose hyper-radiosensitivity in MRC-5 cells

    PubMed Central

    Ye, Fei; Ning, Jing; Liu, Xinguo; Jin, Xiaodong; Wang, Tieshan; Li, Qiang

    2016-01-01

    Low-dose hyper-radiosensitivity (LDHRS) is a hot topic in normal tissue radiation protection. However, the primary causes for LDHRS still remain unclear. In this study, the impact of non-DNA-targeted effects (NTEs) on high-LET radiation–induced LDHRS was investigated. Human normal lung fibroblast MRC-5 cells were irradiated with high-LET carbon ions, and low-dose biological effects (in terms of various bio-endpoints, including colony formation, DNA damage and micronuclei formation) were detected under conditions with and without gap junctional intercellular communication (GJIC) inhibition. LDHRS was observed when the radiation dose was <0.2 Gy for all bio-endpoints under investigation, but vanished when the GJIC was suppressed. Based on the probability of cells being hit and micro-dose per cell calculation, we deduced that the LDHRS phenomenon came from the combined action of direct hits and NTEs. We concluded that GJIC definitely plays an important role in cytotoxic substance spreading in high-LET carbon ion–induced LDHRS. PMID:26559335

  20. Policy Choices for Progressive Realization of Universal Health Coverage Comment on "Ethical Perspective: Five Unacceptable Trade-offs on the Path to Universal Health Coverage".

    PubMed

    Tangcharoensathien, Viroj; Patcharanarumol, Walaiporn; Panichkriangkrai, Warisa; Sommanustweechai, Angkana

    2016-07-31

    In responses to Norheim's editorial, this commentary offers reflections from Thailand, how the five unacceptable trade-offs were applied to the universal health coverage (UHC) reforms between 1975 and 2002 when the whole 64 million people were covered by one of the three public health insurance systems. This commentary aims to generate global discussions on how best UHC can be gradually achieved. Not only the proposed five discrete trade-offs within each dimension, there are also trade-offs between the three dimensions of UHC such as population coverage, service coverage and cost coverage. Findings from Thai UHC show that equity is applied for the population coverage extension, when the low income households and the informal sector were the priority population groups for coverage extension by different prepayment schemes in 1975 and 1984, respectively. With an exception of public sector employees who were historically covered as part of fringe benefits were covered well before the poor. The private sector employees were covered last in 1990. Historically, Thailand applied a comprehensive benefit package where a few items are excluded using the negative list; until there was improved capacities on technology assessment that cost-effectiveness are used for the inclusion of new interventions into the benefit package. Not only cost-effectiveness, but long term budget impact, equity and ethical considerations are taken into account. Cost coverage is mostly determined by the fiscal capacities. Close ended budget with mix of provider payment methods are used as a tool for trade-off service coverage and financial risk protection. Introducing copayment in the context of fee-for-service can be harmful to beneficiaries due to supplier induced demands, inefficiency and unpredictable out of pocket payment by households. UHC achieves favorable outcomes as it was implemented when there was a full geographical coverage of primary healthcare coverage in all districts and sub