Sample records for target margin assessment

  1. Margin estimation and disturbances of irradiation field in layer-stacking carbon-ion beams for respiratory moving targets.

    PubMed

    Tajiri, Shinya; Tashiro, Mutsumi; Mizukami, Tomohiro; Tsukishima, Chihiro; Torikoshi, Masami; Kanai, Tatsuaki

    2017-11-01

    Carbon-ion therapy by layer-stacking irradiation for static targets has been practised in clinical treatments. In order to apply this technique to a moving target, disturbances of carbon-ion dose distributions due to respiratory motion have been studied based on the measurement using a respiratory motion phantom, and the margin estimation given by the square root of the summation Internal margin2+Setup margin2 has been assessed. We assessed the volume in which the variation in the ratio of the dose for a target moving due to respiration relative to the dose for a static target was within 5%. The margins were insufficient for use with layer-stacking irradiation of a moving target, and an additional margin was required. The lateral movement of a target converts to the range variation, as the thickness of the range compensator changes with the movement of the target. Although the additional margin changes according to the shape of the ridge filter, dose uniformity of 5% can be achieved for a spherical target 93 mm in diameter when the upward range variation is limited to 5 mm and the additional margin of 2.5 mm is applied in case of our ridge filter. Dose uniformity in a clinical target largely depends on the shape of the mini-peak as well as on the bolus shape. We have shown the relationship between range variation and dose uniformity. In actual therapy, the upper limit of target movement should be considered by assessing the bolus shape. © The Author 2017. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  2. Targeted delivery of cancer-specific multimodal contrast agents for intraoperative detection of tumor boundaries and therapeutic margins

    NASA Astrophysics Data System (ADS)

    Xu, Ronald X.; Xu, Jeff S.; Huang, Jiwei; Tweedle, Michael F.; Schmidt, Carl; Povoski, Stephen P.; Martin, Edward W.

    2010-02-01

    Background: Accurate assessment of tumor boundaries and intraoperative detection of therapeutic margins are important oncologic principles for minimal recurrence rates and improved long-term outcomes. However, many existing cancer imaging tools are based on preoperative image acquisition and do not provide real-time intraoperative information that supports critical decision-making in the operating room. Method: Poly lactic-co-glycolic acid (PLGA) microbubbles (MBs) and nanobubbles (NBs) were synthesized by a modified double emulsion method. The MB and NB surfaces were conjugated with CC49 antibody to target TAG-72 antigen, a human glycoprotein complex expressed in many epithelial-derived cancers. Multiple imaging agents were encapsulated in MBs and NBs for multimodal imaging. Both one-step and multi-step cancer targeting strategies were explored. Active MBs/NBs were also fabricated for therapeutic margin assessment in cancer ablation therapies. Results: The multimodal contrast agents and the cancer-targeting strategies were tested on tissue simulating phantoms, LS174 colon cancer cell cultures, and cancer xenograft nude mice. Concurrent multimodal imaging was demonstrated using fluorescence and ultrasound imaging modalities. Technical feasibility of using active MBs and portable imaging tools such as ultrasound for intraoperative therapeutic margin assessment was demonstrated in a biological tissue model. Conclusion: The cancer-specific multimodal contrast agents described in this paper have the potential for intraoperative detection of tumor boundaries and therapeutic margins.

  3. Sci—Thur PM: Planning and Delivery — 04: Respiratory margin derivation and verification in partial breast irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quirk, S; Conroy, L; Smith, WL

    Partial breast irradiation (PBI) following breast-conserving surgery is emerging as an effective means to achieve local control and reduce irradiated breast volume. Patients are planned on a static CT image; however, treatment is delivered while the patient is free-breathing. Respiratory motion can degrade plan quality by reducing target coverage and/or dose homogeneity. A variety of methods can be used to determine the required margin for respiratory motion in PBI. We derive geometric and dosimetric respiratory 1D margin. We also verify the adequacy of the typical 5 mm respiratory margin in 3D by evaluating plan quality for increasing respiratory amplitudes (2–20more » mm). Ten PBI plans were used for dosimetric evaluation. A database of volunteer respiratory data, with similar characteristics to breast cancer patients, was used for this study. We derived a geometric 95%-margin of 3 mm from the population respiratory data. We derived a dosimetric 95%-margin of 2 mm by convolving 1D dose profiles with respiratory probability density functions. The 5 mm respiratory margin is possibly too large when 1D coverage is assessed and could lead to unnecessary normal tissue irradiation. Assessing margins only for coverage may be insufficient; 3D dosimetric assessment revealed degradation in dose homogeneity is the limiting factor, not target coverage. Hotspots increased even for the smallest respiratory amplitudes, while target coverage only degraded at amplitudes greater than 10 mm. The 5 mm respiratory margin is adequate for coverage, but due to plan quality degradation, respiratory management is recommended for patients with respiratory amplitudes greater than 10 mm.« less

  4. Utilization of cone-beam CT for offline evaluation of target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment.

    PubMed

    Paluska, Petr; Hanus, Josef; Sefrova, Jana; Rouskova, Lucie; Grepl, Jakub; Jansa, Jan; Kasaova, Linda; Hodek, Miroslav; Zouhar, Milan; Vosmik, Milan; Petera, Jiri

    2012-01-01

    To assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction. Implementation of IGRT should influence safety margins. Utilization of cone-beam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose distribution. Seventeen prostate patients were treated with daily bony anatomy image-guidance. Cone-beam CT (CBCT) scans were acquired once a week immediately after bony anatomy alignment. After the prostate, seminal vesicles, rectum and bladder were contoured, the delivered dose distribution was reconstructed. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed a 1 cm safety margin. Alternative plans assuming a smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with the initial ones. Rectal and bladder volumes irradiated with doses higher than 75 Gy, 70 Gy, 60 Gy, 50 Gy and 40 Gy were analyzed. In 12% of reconstructed plans the prostate coverage was not sufficient. The prostate underdosage was observed in 5 patients. Coverage of seminal vesicles was not satisfactory in 3% of plans. Most of the target underdosage corresponded to excessive rectal or bladder filling. Evaluation of alternative plans assuming a smaller 7 mm margin revealed 22% and 11% of plans where prostate and seminal vesicles coverage, respectively, was compromised. These were distributed over 8 and 7 patients, respectively. Sufficient dose coverage of target volumes was not achieved for all patients. Reducing of safety margin is not acceptable. Initial rectal and bladder volumes cannot be considered representative for subsequent treatment.

  5. Metastasis Infiltration: An Investigation of the Postoperative Brain-Tumor Interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raore, Bethwel; Schniederjan, Matthew; Prabhu, Roshan

    Purpose: This study aims to evaluate brain infiltration of metastatic tumor cells past the main tumor resection margin to assess the biological basis for the use of stereotactic radiosurgery treatment of the tumor resection cavity and visualized resection edge or clinical target volume. Methods and Materials: Resection margin tissue was obtained after gross total resection of a small group of metastatic lesions from a variety of primary sources. The tissue at the border of the tumor and brain tissue was carefully oriented and processed to evaluate the presence of tumor cells within brain tissue and their distance from the resectionmore » margin. Results: Microscopic assessment of the radially oriented tissue samples showed no tumor cells infiltrating the surrounding brain tissue. Among the positive findings were reactive astrocytosis observed on the brain tissue immediately adjacent to the tumor resection bed margin. Conclusions: The lack of evidence of metastatic tumor cell infiltration into surrounding brain suggests the need to target only a narrow depth of the resection cavity margin to minimize normal tissue injury and prevent treatment size-dependent stereotactic radiosurgery complications.« less

  6. Is it necessary to plan with safety margins for actively scanned proton therapy?

    NASA Astrophysics Data System (ADS)

    Albertini, F.; Hug, E. B.; Lomax, A. J.

    2011-07-01

    In radiation therapy, a plan is robust if the calculated and the delivered dose are in agreement, even in the case of different uncertainties. The current practice is to use safety margins, expanding the clinical target volume sufficiently enough to account for treatment uncertainties. This, however, might not be ideal for proton therapy and in particular when using intensity modulated proton therapy (IMPT) plans as degradation in the dose conformity could also be found in the middle of the target resulting from misalignments of highly in-field dose gradients. Single field uniform dose (SFUD) and IMPT plans have been calculated for different anatomical sites and the need for margins has been assessed by analyzing plan robustness to set-up and range uncertainties. We found that the use of safety margins is a good way to improve plan robustness for SFUD and IMPT plans with low in-field dose gradients but not necessarily for highly modulated IMPT plans for which only a marginal improvement in plan robustness could be detected through the definition of a planning target volume.

  7. SU-F-J-17: Patient Localization Using MRI-Guided Soft Tissue for Head-And-Neck Radiotherapy: Indication for Margin Reduction and Its Feasibility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qi, X; Yang, Y; Jack, N

    Purpose: On-board MRI provides superior soft-tissue contrast, allowing patient alignment using tumor or nearby critical structures. This study aims to study H&N MRI-guided IGRT to analyze inter-fraction patient setup variations using soft-tissue targets and design appropriate CTV-to-PTV margin and clinical implication. Methods: 282 MR images for 10 H&N IMRT patients treated on a ViewRay system were retrospectively analyzed. Patients were immobilized using a thermoplastic mask on a customized headrest fitted in a radiofrequency coil and positioned to soft-tissue targets. The inter-fraction patient displacements were recorded to compute the PTV margins using the recipe: 2.5∑+0.7σ. New IMRT plans optimized on themore » revised PTVs were generated to evaluate the delivered dose distributions. An in-house dose deformation registration tool was used to assess the resulting dosimetric consequences when margin adaption is performed based on weekly MR images. The cumulative doses were compared to the reduced margin plans for targets and critical structures. Results: The inter-fraction displacements (and standard deviations), ∑ and σ were tabulated for MRI and compared to kVCBCT. The computed CTV-to-PTV margin was 3.5mm for soft-tissue based registration. There were minimal differences between the planned and delivered doses when comparing clinical and the PTV reduced margin plans: the paired t-tests yielded p=0.38 and 0.66 between the planned and delivered doses for the adapted margin plans for the maximum cord and mean parotid dose, respectively. Target V95 received comparable doses as planned for the reduced margin plans. Conclusion: The 0.35T MRI offers acceptable soft-tissue contrast and good spatial resolution for patient alignment and target visualization. Better tumor conspicuity from MRI allows soft-tissue based alignments with potentially improved accuracy, suggesting a benefit of margin reduction for H&N radiotherapy. The reduced margin plans (i.e., 2 mm) resulted in improved normal structure sparing and accurate dose delivery to achieve intended treatment goal under MR guidance.« less

  8. Estimation of marginal costs at existing waste treatment facilities.

    PubMed

    Martinez-Sanchez, Veronica; Hulgaard, Tore; Hindsgaul, Claus; Riber, Christian; Kamuk, Bettina; Astrup, Thomas F

    2016-04-01

    This investigation aims at providing an improved basis for assessing economic consequences of alternative Solid Waste Management (SWM) strategies for existing waste facilities. A bottom-up methodology was developed to determine marginal costs in existing facilities due to changes in the SWM system, based on the determination of average costs in such waste facilities as function of key facility and waste compositional parameters. The applicability of the method was demonstrated through a case study including two existing Waste-to-Energy (WtE) facilities, one with co-generation of heat and power (CHP) and another with only power generation (Power), affected by diversion strategies of five waste fractions (fibres, plastic, metals, organics and glass), named "target fractions". The study assumed three possible responses to waste diversion in the WtE facilities: (i) biomass was added to maintain a constant thermal load, (ii) Refused-Derived-Fuel (RDF) was included to maintain a constant thermal load, or (iii) no reaction occurred resulting in a reduced waste throughput without full utilization of the facility capacity. Results demonstrated that marginal costs of diversion from WtE were up to eleven times larger than average costs and dependent on the response in the WtE plant. Marginal cost of diversion were between 39 and 287 € Mg(-1) target fraction when biomass was added in a CHP (from 34 to 303 € Mg(-1) target fraction in the only Power case), between -2 and 300 € Mg(-1) target fraction when RDF was added in a CHP (from -2 to 294 € Mg(-1) target fraction in the only Power case) and between 40 and 303 € Mg(-1) target fraction when no reaction happened in a CHP (from 35 to 296 € Mg(-1) target fraction in the only Power case). Although average costs at WtE facilities were highly influenced by energy selling prices, marginal costs were not (provided a response was initiated at the WtE to keep constant the utilized thermal capacity). Failing to systematically address and include costs in existing waste facilities in decision-making may unintendedly lead to higher overall costs at societal level. To avoid misleading conclusions, economic assessment of alternative SWM solutions should not only consider potential costs associated with alternative treatment but also include marginal costs associated with existing facilities. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turley, Jessica; Claridge Mackonis, Elizabeth

    To evaluate in-field megavoltage (MV) imaging of simultaneously integrated boost (SIB) breast fields to determine its feasibility in treatment verification for the SIB breast radiotherapy technique, and to assess whether the current-imaging protocol and treatment margins are sufficient. For nine patients undergoing SIB breast radiotherapy, in-field MV images of the SIB fields were acquired on days that regular treatment verification imaging was performed. The in-field images were matched offline according to the scar wire on digitally reconstructed radiographs. The offline image correction results were then applied to a margin recipe formula to calculate safe margins that account for random andmore » systematic uncertainties in the position of the boost volume when an offline correction protocol has been applied. After offline assessment of the acquired images, 96% were within the tolerance set in the current department-imaging protocol. Retrospectively performing the maximum position deviations on the Eclipse™ treatment planning system demonstrated that the clinical target volume (CTV) boost received a minimum dose difference of 0.4% and a maximum dose difference of 1.4% less than planned. Furthermore, applying our results to the Van Herk margin formula to ensure that 90% of patients receive 95% of the prescribed dose, the calculated CTV margins were comparable to the current departmental procedure used. Based on the in-field boost images acquired and the feasible application of these results to the margin formula the current CTV-planning target volume margins used are appropriate for the accurate treatment of the SIB boost volume without additional imaging.« less

  10. 4D-Listmode-PET-CT and 4D-CT for optimizing PTV margins in gastric lymphoma : Determination of intra- and interfractional gastric motion.

    PubMed

    Reinartz, Gabriele; Haverkamp, Uwe; Wullenkord, Ramona; Lehrich, Philipp; Kriz, Jan; Büther, Florian; Schäfers, Klaus; Schäfers, Michael; Eich, Hans Theodor

    2016-05-01

    New imaging protocols for radiotherapy in localized gastric lymphoma were evaluated to optimize planning target volume (PTV) margin and determine intra-/interfractional variation of the stomach. Imaging of 6 patients was explored prospectively. Intensity-modulated radiotherapy (IMRT) planning was based on 4D/3D imaging of computed tomography (CT) and positron-emission tomography (PET)-CT. Static and motion gross tumor volume (sGTV and mGTV, respectively) were distinguished by defining GTV (empty stomach), clinical target volume (CTV = GTV + 5 mm margin), PTV (GTV + 10/15/20/25 mm margins)  plus paraaortic lymph nodes and proximal duodenum. Overlap of 4D-Listmode-PET-based mCTV with 3D-CT-based PTV (increasing margins) and V95/D95 of mCTV were evaluated. Gastric shifts were determined using online cone-beam CT. Dose contribution to organs at risk was assessed. The 4D data demonstrate considerable intra-/interfractional variation of the stomach, especially along the vertical axis. Conventional 3D-CT planning utilizing advancing PTV margins of 10/15/20/25 mm resulted in rising dose coverage of mCTV (4D-Listmode-PET-Summation-CT) and rising D95 and V95 of mCTV. A PTV margin of 15 mm was adequate in 3 of 6 patients, a PTV margin of 20 mm was adequate in 4 of 6 patients, and a PTV margin of 25 mm was adequate in 5 of 6 patients. IMRT planning based on 4D-PET-CT/4D-CT together with online cone-beam CT is advisable to individualize the PTV margin and optimize target coverage in gastric lymphoma.

  11. Thick tissue diffusion model with binding to optimize topical staining in fluorescence breast cancer margin imaging

    NASA Astrophysics Data System (ADS)

    Xu, Xiaochun; Kang, Soyoung; Navarro-Comes, Eric; Wang, Yu; Liu, Jonathan T. C.; Tichauer, Kenneth M.

    2018-03-01

    Intraoperative tumor/surgical margin assessment is required to achieve higher tumor resection rate in breast-conserving surgery. Though current histology provides incomparable accuracy in margin assessment, thin tissue sectioning and the limited field of view of microscopy makes histology too time-consuming for intraoperative applications. If thick tissue, wide-field imaging can provide an acceptable assessment of tumor cells at the surface of resected tissues, an intraoperative protocol can be developed to guide the surgery and provide immediate feedback for surgeons. Topical staining of margins with cancer-targeted molecular imaging agents has the potential to provide the sensitivity needed to see microscopic cancer on a wide-field image; however, diffusion and nonspecific retention of imaging agents in thick tissue can significantly diminish tumor contrast with conventional methods. Here, we present a mathematical model to accurately simulate nonspecific retention, binding, and diffusion of imaging agents in thick tissue topical staining to guide and optimize future thick tissue staining and imaging protocol. In order to verify the accuracy and applicability of the model, diffusion profiles of cancer targeted and untargeted (control) nanoparticles at different staining times in A431 tumor xenografts were acquired for model comparison and tuning. The initial findings suggest the existence of nonspecific retention in the tissue, especially at the tissue surface. The simulator can be used to compare the effect of nonspecific retention, receptor binding and diffusion under various conditions (tissue type, imaging agent) and provides optimal staining and imaging protocols for targeted and control imaging agent.

  12. Acculturation and health-related quality of life: results from the German National Cohort migrant feasibility study.

    PubMed

    Brand, Tilman; Samkange-Zeeb, Florence; Ellert, Ute; Keil, Thomas; Krist, Lilian; Dragano, Nico; Jöckel, Karl-Heinz; Razum, Oliver; Reiss, Katharina; Greiser, Karin Halina; Zimmermann, Heiko; Becher, Heiko; Zeeb, Hajo

    2017-06-01

    We assessed the association between acculturation and health-related quality of life (HRQoL) among persons with a Turkish migrant background in Germany. 1226 adults of Turkish origin were recruited in four German cities. Acculturation was assessed using the Frankfurt Acculturation Scale resulting in four groups (integration, assimilation, separation and marginalization). Short Form-8 physical and mental components were used to assess the HRQoL. Associations were analysed with linear regression models. Of the respondents, 20% were classified as integrated, 29% assimilated, 29% separated and 19% as marginalized. Separation was associated with poorer physical and mental health (linear regression coefficient (RC) = -2.3, 95% CI -3.9 to -0.8 and RC = -2.4, 95% CI -4.4 to -0.5, respectively; reference: integration). Marginalization was associated with poorer mental health in descendants of migrants (RC = -6.4, 95% CI -12.0 to -0.8; reference: integration). Separation and marginalization are associated with a poorer HRQoL. Policies should support the integration of migrants, and health promotion interventions should target separated and marginalized migrants to improve their HRQoL.

  13. Inter- and Intrafraction Uncertainty in Prostate Bed Image-Guided Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Kitty; Palma, David A.; Department of Oncology, University of Western Ontario, London

    2012-10-01

    Purpose: The goals of this study were to measure inter- and intrafraction setup error and prostate bed motion (PBM) in patients undergoing post-prostatectomy image-guided radiotherapy (IGRT) and to propose appropriate population-based three-dimensional clinical target volume to planning target volume (CTV-PTV) margins in both non-IGRT and IGRT scenarios. Methods and Materials: In this prospective study, 14 patients underwent adjuvant or salvage radiotherapy to the prostate bed under image guidance using linac-based kilovoltage cone-beam CT (kV-CBCT). Inter- and intrafraction uncertainty/motion was assessed by offline analysis of three consecutive daily kV-CBCT images of each patient: (1) after initial setup to skin marks, (2)more » after correction for positional error/immediately before radiation treatment, and (3) immediately after treatment. Results: The magnitude of interfraction PBM was 2.1 mm, and intrafraction PBM was 0.4 mm. The maximum inter- and intrafraction prostate bed motion was primarily in the anterior-posterior direction. Margins of at least 3-5 mm with IGRT and 4-7 mm without IGRT (aligning to skin marks) will ensure 95% of the prescribed dose to the clinical target volume in 90% of patients. Conclusions: PBM is a predominant source of intrafraction error compared with setup error and has implications for appropriate PTV margins. Based on inter- and estimated intrafraction motion of the prostate bed using pre- and post-kV-CBCT images, CBCT IGRT to correct for day-to-day variances can potentially reduce CTV-PTV margins by 1-2 mm. CTV-PTV margins for prostate bed treatment in the IGRT and non-IGRT scenarios are proposed; however, in cases with more uncertainty of target delineation and image guidance accuracy, larger margins are recommended.« less

  14. Computerized margin and texture analyses for differentiating bacterial pneumonia and invasive mucinous adenocarcinoma presenting as consolidation.

    PubMed

    Koo, Hyun Jung; Kim, Mi Young; Koo, Ja Hwan; Sung, Yu Sub; Jung, Jiwon; Kim, Sung-Han; Choi, Chang-Min; Kim, Hwa Jung

    2017-01-01

    Radiologists have used margin characteristics based on routine visual analysis; however, the attenuation changes at the margin of the lesion on CT images have not been quantitatively assessed. We established a CT-based margin analysis method by comparing a target lesion with normal lung attenuation, drawing a slope to represent the attenuation changes. This approach was applied to patients with invasive mucinous adenocarcinoma (n = 40) or bacterial pneumonia (n = 30). Correlations among multiple regions of interest (ROIs) were obtained using intraclass correlation coefficient (ICC) values. CT visual assessment, margin and texture parameters were compared for differentiating the two disease entities. The attenuation and margin parameters in multiple ROIs showed excellent ICC values. Attenuation slopes obtained at the margins revealed a difference between invasive mucinous adenocarcinoma and pneumonia (P<0.001), and mucinous adenocarcinoma produced a sharply declining attenuation slope. On multivariable logistic regression analysis, pneumonia had an ill-defined margin (odds ratio (OR), 4.84; 95% confidence interval (CI), 1.26-18.52; P = 0.02), ground-glass opacity (OR, 8.55; 95% CI, 2.09-34.95; P = 0.003), and gradually declining attenuation at the margin (OR, 12.63; 95% CI, 2.77-57.51, P = 0.001). CT-based margin analysis method has a potential to act as an imaging parameter for differentiating invasive mucinous adenocarcinoma and bacterial pneumonia.

  15. Real-time assessment of breast surgical margins with fluorescence-guided microscopy (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Iftimia, Nicusor V.; Park, Jesung; Maguluri, Gopi N.; Krishnamurthy, Savitri

    2017-02-01

    A novel multimodal optical imaging approach for real-time assessment of surgical margins on breast cancer lumpectomy specimens is presented. Our approach is to target cancer cells using an optically silent peptide substrate containing two (NIR) fluorochromes, internally quenched, which are cleaved by highly expressed breast cancer enzymes, like urokinase-type plasminogen activator (uPA). Thus this agent becomes highly fluorescent only on the cancer area when the specimen is excited by a NIR laser beam. A fluorescence imager is used to highlight cancer-suspect margins on the surgical specimen, while high-resolution optical coherence tomography (OCT) imaging is used to visualize tissue morphology on the highlighted areas and confirm or rule out cancer presence. This technology will hopefully increase the success rate of cancer surgeries, reduce the risk of cancer recurrence and significantly reduce US healthcare costs.

  16. Estimation of marginal abatement costs of CO2 in Chinese provinces under 2020 carbon emission rights allocation: 2005-2020.

    PubMed

    Duan, Fumei; Wang, Yong; Wang, Ying; Zhao, Han

    2018-06-16

    The calculation of marginal abatement costs of CO 2 plays a vital role in meeting China's 2020 emission reduction targets by providing reference for determining carbon tax and carbon trading pricing. However, most existing researches only used one method to discuss regional and industrial marginal abatement costs, and almost no studies predicted future marginal abatement costs from the perspective of CO 2 emission efficiency. To make up for the gaps, this paper first estimates marginal abatement costs of CO 2 in three major industries of 30 provinces in China from 2005 to 2015 based on three assumptions. Second, based on the principle of fairness and efficiency, China's 2020 emission reduction targets are decomposed by province. Based on the ZSG-C-DDF model, the marginal abatement costs of CO 2 in all provinces in China in 2020 are estimated and compared with the marginal abatement costs of 2005 to 2015. The results show that (1) from 2005 to 2015, marginal abatement costs of CO 2 in all provinces show a fluctuating upward trend; (2) compared with the marginal abatement costs of primary industry or tertiary industry, most provinces have lower marginal abatement costs for secondary industry; and (3) the average marginal abatement costs of CO 2 for China in 2020 are 2766.882 Yuan/tonne for the 40% carbon intensity reduction target and 3334.836 Yuan/tonne for the 45% target, showing that the higher the emission reduction target, the higher the marginal abatement costs of CO 2 . (4) Overall, the average marginal abatement costs of CO 2 in China by 2020 are higher than those in 2005-2015. The empirical analysis in this paper can provide multiple references for environmental policy makers.

  17. Craniocaudal Safety Margin Calculation Based on Interfractional Changes in Tumor Motion in Lung SBRT Assessed With an EPID in Cine Mode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ueda, Yoshihiro, E-mail: ueda-yo@mc.pref.osaka.jp; Miyazaki, Masayoshi; Nishiyama, Kinji

    2012-07-01

    Purpose: To evaluate setup error and interfractional changes in tumor motion magnitude using an electric portal imaging device in cine mode (EPID cine) during the course of stereotactic body radiation therapy (SBRT) for non-small-cell lung cancer (NSCLC) and to calculate margins to compensate for these variations. Materials and Methods: Subjects were 28 patients with Stage I NSCLC who underwent SBRT. Respiratory-correlated four-dimensional computed tomography (4D-CT) at simulation was binned into 10 respiratory phases, which provided average intensity projection CT data sets (AIP). On 4D-CT, peak-to-peak motion of the tumor (M-4DCT) in the craniocaudal direction was assessed and the tumor centermore » (mean tumor position [MTP]) of the AIP (MTP-4DCT) was determined. At treatment, the tumor on cone beam CT was registered to that on AIP for patient setup. During three sessions of irradiation, peak-to-peak motion of the tumor (M-cine) and the mean tumor position (MTP-cine) were obtained using EPID cine and in-house software. Based on changes in tumor motion magnitude ( Increment M) and patient setup error ( Increment MTP), defined as differences between M-4DCT and M-cine and between MTP-4DCT and MTP-cine, a margin to compensate for these variations was calculated with Stroom's formula. Results: The means ({+-}standard deviation: SD) of M-4DCT and M-cine were 3.1 ({+-}3.4) and 4.0 ({+-}3.6) mm, respectively. The means ({+-}SD) of Increment M and Increment MTP were 0.9 ({+-}1.3) and 0.2 ({+-}2.4) mm, respectively. Internal target volume-planning target volume (ITV-PTV) margins to compensate for Increment M, Increment MTP, and both combined were 3.7, 5.2, and 6.4 mm, respectively. Conclusion: EPID cine is a useful modality for assessing interfractional variations of tumor motion. The ITV-PTV margins to compensate for these variations can be calculated.« less

  18. SU-E-J-188: Theoretical Estimation of Margin Necessary for Markerless Motion Tracking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patel, R; Block, A; Harkenrider, M

    2015-06-15

    Purpose: To estimate the margin necessary to adequately cover the target using markerless motion tracking (MMT) of lung lesions given the uncertainty in tracking and the size of the target. Methods: Simulations were developed in Matlab to determine the effect of tumor size and tracking uncertainty on the margin necessary to achieve adequate coverage of the target. For simplicity, the lung tumor was approximated by a circle on a 2D radiograph. The tumor was varied in size from a diameter of 0.1 − 30 mm in increments of 0.1 mm. From our previous studies using dual energy markerless motion tracking,more » we estimated tracking uncertainties in x and y to have a standard deviation of 2 mm. A Gaussian was used to simulate the deviation between the tracked location and true target location. For each size tumor, 100,000 deviations were randomly generated, the margin necessary to achieve at least 95% coverage 95% of the time was recorded. Additional simulations were run for varying uncertainties to demonstrate the effect of the tracking accuracy on the margin size. Results: The simulations showed an inverse relationship between tumor size and margin necessary to achieve 95% coverage 95% of the time using the MMT technique. The margin decreased exponentially with target size. An increase in tracking accuracy expectedly showed a decrease in margin size as well. Conclusion: In our clinic a 5 mm expansion of the internal target volume (ITV) is used to define the planning target volume (PTV). These simulations show that for tracking accuracies in x and y better than 2 mm, the margin required is less than 5 mm. This simple simulation can provide physicians with a guideline estimation for the margin necessary for use of MMT clinically based on the accuracy of their tracking and the size of the tumor.« less

  19. Effect of lung and target density on small-field dose coverage and PTV definition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Higgins, Patrick D., E-mail: higgi010@umn.edu; Ehler, Eric D.; Cho, Lawrence C.

    We have studied the effect of target and lung density on block margin for small stereotactic body radiotherapy (SBRT) targets. A phantom (50 × 50 × 50 cm{sup 3}) was created in the Pinnacle (V9.2) planning system with a 23-cm diameter lung region of interest insert. Diameter targets of 1.6, 2.0, 3.0, and 4.0 cm were placed in the lung region of interest and centered at a physical depth of 15 cm. Target densities evaluated were 0.1 to 1.0 g/cm{sup 3}, whereas the surrounding lung density was varied between 0.05 and 0.6 g/cm{sup 3}. A dose of 100 cGy wasmore » delivered to the isocenter via a single 6-MV field, and the ratio of the average dose to points defining the lateral edges of the target to the isocenter dose was recorded for each combination. Field margins were varied from none to 1.5 cm in 0.25-cm steps. Data obtained in the phantom study were used to predict planning treatment volume (PTV) margins that would match the clinical PTV and isodose prescription for a clinical set of 39 SBRT cases. The average internal target volume (ITV) density was 0.73 ± 0.17, average local lung density was 0.33 ± 0.16, and average ITV diameter was 2.16 ± 0.8 cm. The phantom results initially underpredicted PTV margins by 0.35 cm. With this offset included in the model, the ratio of predicted-to-clinical PTVs was 1.05 ± 0.32. For a given target and lung density, it was found that treatment margin was insensitive to target diameter, except for the smallest (1.6-cm diameter) target, for which the treatment margin was more sensitive to density changes than the larger targets. We have developed a graphical relationship for block margin as a function of target and lung density, which should save time in the planning phase by shortening the design of PTV margins that can satisfy Radiation Therapy Oncology Group mandated treatment volume ratios.« less

  20. Generalized Tumor Dose for Treatment Planning Decision Support

    NASA Astrophysics Data System (ADS)

    Zuniga, Areli A.

    Modern radiation therapy techniques allow for improved target conformity and normal tissue sparing. These highly conformal treatment plans have allowed dose escalation techniques increasing the probability of tumor control. At the same time this conformation has introduced inhomogeneous dose distributions, making delivered dose characterizations more difficult. The concept of equivalent uniform dose (EUD) characterizes a heterogeneous dose distribution within irradiated structures as a single value and has been used in biologically based treatment planning (BBTP); however, there are no substantial validation studies on clinical outcome data supporting EUD's use and therefore has not been widely adopted as decision-making support. These highly conformal treatment plans have also introduced the need for safety margins around the target volume. These margins are designed to minimize geometrical misses, and to compensate for dosimetric and treatment delivery uncertainties. The margin's purpose is to reduce the chance of tumor recurrence. This dissertation introduces a new EUD formulation designed especially for tumor volumes, called generalized Tumor Dose (gTD). It also investigates, as a second objective, margins extensions for potential improvements in local control while maintaining or minimizing toxicity. The suitability of gTD to rank LC was assessed by means of retrospective studies in a head and neck (HN) squamous cell carcinoma (SCC) and non-small cell lung cancer (NSCLC) cohorts. The formulation was optimized based on two datasets (one of each type) and then, model validation was assessed on independent cohorts. The second objective of this dissertation was investigated by ranking the probability of LC of the primary disease adding different margin sizes. In order to do so, an already published EUD formula was used retrospectively in a HN and a NSCLC datasets. Finally, recommendations for the viability to implement this new formulation into a routine treatment planning process as well as the revision of safety margins to improve local tumor control maximizing normal tissue sparing in SCC of the HN and NSCLC are discussed.

  1. Sensitivity of postplanning target and OAR coverage estimates to dosimetric margin distribution sampling parameters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu Huijun; Gordon, J. James; Siebers, Jeffrey V.

    2011-02-15

    Purpose: A dosimetric margin (DM) is the margin in a specified direction between a structure and a specified isodose surface, corresponding to a prescription or tolerance dose. The dosimetric margin distribution (DMD) is the distribution of DMs over all directions. Given a geometric uncertainty model, representing inter- or intrafraction setup uncertainties or internal organ motion, the DMD can be used to calculate coverage Q, which is the probability that a realized target or organ-at-risk (OAR) dose metric D{sub v} exceeds the corresponding prescription or tolerance dose. Postplanning coverage evaluation quantifies the percentage of uncertainties for which target and OAR structuresmore » meet their intended dose constraints. The goal of the present work is to evaluate coverage probabilities for 28 prostate treatment plans to determine DMD sampling parameters that ensure adequate accuracy for postplanning coverage estimates. Methods: Normally distributed interfraction setup uncertainties were applied to 28 plans for localized prostate cancer, with prescribed dose of 79.2 Gy and 10 mm clinical target volume to planning target volume (CTV-to-PTV) margins. Using angular or isotropic sampling techniques, dosimetric margins were determined for the CTV, bladder and rectum, assuming shift invariance of the dose distribution. For angular sampling, DMDs were sampled at fixed angular intervals {omega} (e.g., {omega}=1 deg., 2 deg., 5 deg., 10 deg., 20 deg.). Isotropic samples were uniformly distributed on the unit sphere resulting in variable angular increments, but were calculated for the same number of sampling directions as angular DMDs, and accordingly characterized by the effective angular increment {omega}{sub eff}. In each direction, the DM was calculated by moving the structure in radial steps of size {delta}(=0.1,0.2,0.5,1 mm) until the specified isodose was crossed. Coverage estimation accuracy {Delta}Q was quantified as a function of the sampling parameters {omega} or {omega}{sub eff} and {delta}. Results: The accuracy of coverage estimates depends on angular and radial DMD sampling parameters {omega} or {omega}{sub eff} and {delta}, as well as the employed sampling technique. Target |{Delta}Q|<1% and OAR |{Delta}Q|<3% can be achieved with sampling parameters {omega} or {omega}{sub eff}=20 deg., {delta}=1 mm. Better accuracy (target |{Delta}Q|<0.5% and OAR |{Delta}Q|<{approx}1%) can be achieved with {omega} or {omega}{sub eff}=10 deg., {delta}=0.5 mm. As the number of sampling points decreases, the isotropic sampling method maintains better accuracy than fixed angular sampling. Conclusions: Coverage estimates for post-planning evaluation are essential since coverage values of targets and OARs often differ from the values implied by the static margin-based plans. Finer sampling of the DMD enables more accurate assessment of the effect of geometric uncertainties on coverage estimates prior to treatment. DMD sampling with {omega} or {omega}{sub eff}=10 deg. and {delta}=0.5 mm should be adequate for planning purposes.« less

  2. Sensitivity of postplanning target and OAR coverage estimates to dosimetric margin distribution sampling parameters.

    PubMed

    Xu, Huijun; Gordon, J James; Siebers, Jeffrey V

    2011-02-01

    A dosimetric margin (DM) is the margin in a specified direction between a structure and a specified isodose surface, corresponding to a prescription or tolerance dose. The dosimetric margin distribution (DMD) is the distribution of DMs over all directions. Given a geometric uncertainty model, representing inter- or intrafraction setup uncertainties or internal organ motion, the DMD can be used to calculate coverage Q, which is the probability that a realized target or organ-at-risk (OAR) dose metric D, exceeds the corresponding prescription or tolerance dose. Postplanning coverage evaluation quantifies the percentage of uncertainties for which target and OAR structures meet their intended dose constraints. The goal of the present work is to evaluate coverage probabilities for 28 prostate treatment plans to determine DMD sampling parameters that ensure adequate accuracy for postplanning coverage estimates. Normally distributed interfraction setup uncertainties were applied to 28 plans for localized prostate cancer, with prescribed dose of 79.2 Gy and 10 mm clinical target volume to planning target volume (CTV-to-PTV) margins. Using angular or isotropic sampling techniques, dosimetric margins were determined for the CTV, bladder and rectum, assuming shift invariance of the dose distribution. For angular sampling, DMDs were sampled at fixed angular intervals w (e.g., w = 1 degree, 2 degrees, 5 degrees, 10 degrees, 20 degrees). Isotropic samples were uniformly distributed on the unit sphere resulting in variable angular increments, but were calculated for the same number of sampling directions as angular DMDs, and accordingly characterized by the effective angular increment omega eff. In each direction, the DM was calculated by moving the structure in radial steps of size delta (=0.1, 0.2, 0.5, 1 mm) until the specified isodose was crossed. Coverage estimation accuracy deltaQ was quantified as a function of the sampling parameters omega or omega eff and delta. The accuracy of coverage estimates depends on angular and radial DMD sampling parameters omega or omega eff and delta, as well as the employed sampling technique. Target deltaQ/ < l% and OAR /deltaQ/ < 3% can be achieved with sampling parameters omega or omega eef = 20 degrees, delta =1 mm. Better accuracy (target /deltaQ < 0.5% and OAR /deltaQ < approximately 1%) can be achieved with omega or omega eff = 10 degrees, delta = 0.5 mm. As the number of sampling points decreases, the isotropic sampling method maintains better accuracy than fixed angular sampling. Coverage estimates for post-planning evaluation are essential since coverage values of targets and OARs often differ from the values implied by the static margin-based plans. Finer sampling of the DMD enables more accurate assessment of the effect of geometric uncertainties on coverage estimates prior to treatment. DMD sampling with omega or omega eff = 10 degrees and delta = 0.5 mm should be adequate for planning purposes.

  3. Silica-gold nanoshells as potential intraoperative molecular probes for HER2-overexpression in ex vivo breast tissue using near-infrared reflectance confocal microscopy.

    PubMed

    Bickford, Lissett R; Agollah, Germaine; Drezek, Rebekah; Yu, Tse-Kuan

    2010-04-01

    Obtaining negative margins is critical for breast cancer patients undergoing conservation therapy in order to reduce the reemergence of the original cancer. Currently, breast cancer tumor margins are examined in a pathology lab either while the patient is anesthetized or after the surgical procedure has been terminated. These current methods often result in cancer cells present at the surgical resection margin due to inadequate margin assessment at the point of care. Due to such limitations evident in current diagnoses, tools for increasing the accuracy and speed of tumor margin detection directly in the operating room are still needed. We are exploring the potential of using a nano-biophotonics system to facilitate intraoperative tumor margin assessment ex vivo at the cellular level. By combining bioconjugated silica-based gold nanoshells, which scatter light in the near-infrared, with a portable FDA-approved reflectance confocal microscope, we first validate the use of gold nanoshells as effective reflectance-based imaging probes by evaluating the contrast enhancement of three different HER2-overexpressing cell lines. Additionally, we demonstrate the ability to detect HER2-overexpressing cells in human tissue sections within 5 min of incubation time. This work supports the use of targeted silica-based gold nanoshells as potential real-time molecular probes for HER2-overexpression in human tissue.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nguyen, Brandon T., E-mail: Brandon.Nguyen@act.gov.au; Canberra Hospital, Radiation Oncology Department, Garran, ACT; Deb, Siddhartha

    Purpose: To determine an appropriate clinical target volume for partial breast radiation therapy (PBRT) based on the spatial distribution of residual invasive and in situ carcinoma after wide local excision (WLE) for early breast cancer or ductal carcinoma in situ (DCIS). Methods and Materials: We performed a prospective pathologic study of women potentially eligible for PBRT who had re-excision and/or completion mastectomy after WLE for early breast cancer or DCIS. A pathologic assessment protocol was used to determine the maximum radial extension (MRE) of residual carcinoma from the margin of the initial surgical cavity. Women were stratified by the closestmore » initial radial margin width: negative (>1 mm), close (>0 mm and {<=}1 mm), or involved. Results: The study population was composed of 133 women with a median age of 59 years (range, 27-82 years) and the following stage groups: 0 (13.5%), I (40.6%), II (38.3%), and III (7.5%). The histologic subtypes of the primary tumor were invasive ductal carcinoma (74.4%), invasive lobular carcinoma (12.0%), and DCIS alone (13.5%). Residual carcinoma was present in the re-excision and completion mastectomy specimens in 55.4%, 14.3%, and 7.2% of women with an involved, close, and negative margin, respectively. In the 77 women with a noninvolved radial margin, the MRE of residual disease, if present, was {<=}10 mm in 97.4% (95% confidence interval 91.6-99.5) of cases. Larger MRE measurements were significantly associated with an involved margin (P<.001), tumor size >30 mm (P=.03), premenopausal status (P=.03), and negative progesterone receptor status (P=.05). Conclusions: A clinical target volume margin of 10 mm would encompass microscopic residual disease in >90% of women potentially eligible for PBRT after WLE with noninvolved resection margins.« less

  5. SU-E-J-35: Using CBCT as the Alternative Method of Assessing ITV Volume

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liao, Y; Turian, J; Templeton, A

    2015-06-15

    Purpose To study the accuracy of Internal Target Volumes (ITVs) created on cone beam CT (CBCT) by comparing the visible target volume on CBCT to volumes (GTV, ITV, and PTV) outlined on free breathing (FB) CT and 4DCT. Methods A Quasar Cylindrical Motion Phantom with a 3cm diameter ball (14.14 cc) embedded within a cork insert was set up to simulate respiratory motion with a period of 4 seconds and amplitude of 2cm superioinferiorly and 1cm anterioposteriorly. FBCT and 4DCT images were acquired. A PTV-4D was created on the 4DCT by applying a uniform margin of 5mm to the ITV-CT.more » PTV-FB was created by applying a margin of the motion range plus 5mm, i.e. total of 1.5cm laterally and 2.5cm superioinferiorly to the GTV outlined on the FBCT. A dynamic conformal arc was planned to treat the PTV-FB with 1mm margin. A CBCT was acquired before the treatment, on which the target was delineated. During the treatment, the position of the target was monitored using the EPID in cine mode. Results ITV-CBCT and ITV-CT were measured to be 56.6 and 62.7cc, respectively, with a Dice Coefficient (DC) of 0.94 and disagreement in center of mass (COM) of 0.59 mm. On the other hand, GTV-FB was 11.47cc, 19% less than the known volume of the ball. PTV-FB and PTV-4D were 149 and 116 cc, with a DC of 0.71. Part of the ITV-CT was not enclosed by the PTV-FB despite the large margin. The cine EPID images have confirmed geometrical misses of the target. Similar under-coverage was observed in one clinical case and captured by the CBCT, where the implanted fiducials moved outside PTV-FB. Conclusion ITV-CBCT is in good agreement with ITV-CT. When 4DCT was not available, CBCT can be an effective alternative in determining and verifying the PTV margin.« less

  6. Marginal Structural Models with Counterfactual Effect Modifiers.

    PubMed

    Zheng, Wenjing; Luo, Zhehui; van der Laan, Mark J

    2018-06-08

    In health and social sciences, research questions often involve systematic assessment of the modification of treatment causal effect by patient characteristics. In longitudinal settings, time-varying or post-intervention effect modifiers are also of interest. In this work, we investigate the robust and efficient estimation of the Counterfactual-History-Adjusted Marginal Structural Model (van der Laan MJ, Petersen M. Statistical learning of origin-specific statically optimal individualized treatment rules. Int J Biostat. 2007;3), which models the conditional intervention-specific mean outcome given a counterfactual modifier history in an ideal experiment. We establish the semiparametric efficiency theory for these models, and present a substitution-based, semiparametric efficient and doubly robust estimator using the targeted maximum likelihood estimation methodology (TMLE, e.g. van der Laan MJ, Rubin DB. Targeted maximum likelihood learning. Int J Biostat. 2006;2, van der Laan MJ, Rose S. Targeted learning: causal inference for observational and experimental data, 1st ed. Springer Series in Statistics. Springer, 2011). To facilitate implementation in applications where the effect modifier is high dimensional, our third contribution is a projected influence function (and the corresponding projected TMLE estimator), which retains most of the robustness of its efficient peer and can be easily implemented in applications where the use of the efficient influence function becomes taxing. We compare the projected TMLE estimator with an Inverse Probability of Treatment Weighted estimator (e.g. Robins JM. Marginal structural models. In: Proceedings of the American Statistical Association. Section on Bayesian Statistical Science, 1-10. 1997a, Hernan MA, Brumback B, Robins JM. Marginal structural models to estimate the causal effect of zidovudine on the survival of HIV-positive men. 2000;11:561-570), and a non-targeted G-computation estimator (Robins JM. A new approach to causal inference in mortality studies with sustained exposure periods - application to control of the healthy worker survivor effect. Math Modell. 1986;7:1393-1512.). The comparative performance of these estimators is assessed in a simulation study. The use of the projected TMLE estimator is illustrated in a secondary data analysis for the Sequenced Treatment Alternatives to Relieve Depression (STAR*D) trial where effect modifiers are subject to missing at random.

  7. NF-κB deregulation in splenic marginal zone lymphoma.

    PubMed

    Spina, Valeria; Rossi, Davide

    2016-08-01

    Splenic marginal zone lymphoma is a rare mature B-cell malignancy involving the spleen, bone marrow and blood. Over the past years, the rapid expansion of sequencing technologies allowing the genome-wide assessment of genomic, epigenetic and transcriptional changes has revolutionized our understanding of the biological basis of splenic marginal zone lymphoma by providing a comprehensive and unbiased view of the genes/pathways that are deregulated in this disease. NF-κB is a family of transcription factors that plays critical roles in development, survival, and activation of B lymphocytes. Consistent with the physiological involvement of NF-κB signalling in proliferation and commitment of mature B-cells to the marginal zone of the spleen, many oncogenic mutations involved in constitutive activation of the NF-κB pathway were recently identified in splenic marginal zone lymphoma. This review describes the progress in understanding the mechanism of NF-κB activation in splenic marginal zone lymphoma, including molecular, epigenetic and post-transcriptional modifications of NF-κB genes and of upstream pathways, and discusses how information gained from these efforts has provided new insights on potential targets of diagnostic, prognostic and therapeutic relevance for splenic marginal zone lymphoma. Copyright © 2016. Published by Elsevier Ltd.

  8. Impact of organ shape variations on margin concepts for cervix cancer ART.

    PubMed

    Seppenwoolde, Yvette; Stock, Markus; Buschmann, Martin; Georg, Dietmar; Bauer-Novotny, Kwei-Yuang; Pötter, Richard; Georg, Petra

    2016-09-01

    Target and organ movement motivate adaptive radiotherapy for cervix cancer patients. We investigated the dosimetric impact of margin concepts with different levels of complexity on both organ at risk (OAR) sparing and PTV coverage. Weekly CT and daily CBCT scans were delineated for 10 patients. The dosimetric impact of organ shape variations were evaluated for four (isotropic) margin concepts: two static PTVs (PTV 6mm and PTV 15mm ), a PTV based on ITV of the planning CT and CBCTs of the first treatment week (PTV ART ITV ) and an adaptive PTV based on a library approach (PTV ART Library ). Using static concepts, OAR doses increased with large margins, while smaller margins compromised target coverage. ART PTVs resulted in comparable target coverage and better sparing of bladder (V40Gy: 15% and 7% less), rectum (V40Gy: 18 and 6cc less) and bowel (V40Gy: 106 and 15cc less) compared to PTV 15mm . Target coverage evaluation showed that for elective fields a static 5mm margin sufficed. PTV ART Library achieved the best dosimetric results. However when weighing clinical benefit against workload, ITV margins based on repetitive movement evaluation during the first week also provide improvements over static margin concepts. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. [Target volume margins for lung cancer: internal target volume/clinical target volume].

    PubMed

    Jouin, A; Pourel, N

    2013-10-01

    The aim of this study was to carry out a review of margins that should be used for the delineation of target volumes in lung cancer, with a focus on margins from gross tumour volume (GTV) to clinical target volume (CTV) and internal target volume (ITV) delineation. Our review was based on a PubMed literature search with, as a cornerstone, the 2010 European Organisation for Research and Treatment of Cancer (EORTC) recommandations by De Ruysscher et al. The keywords used for the search were: radiotherapy, lung cancer, clinical target volume, internal target volume. The relevant information was categorized under the following headings: gross tumour volume definition (GTV), CTV-GTV margin (first tumoural CTV then nodal CTV definition), in field versus elective nodal irradiation, metabolic imaging role through the input of the PET scanner for tumour target volume and limitations of PET-CT imaging for nodal target volume definition, postoperative radiotherapy target volume definition, delineation of target volumes after induction chemotherapy; then the internal target volume is specified as well as tumoural mobility for lung cancer and respiratory gating techniques. Finally, a chapter is dedicated to planning target volume definition and another to small cell lung cancer. For each heading, the most relevant and recent clinical trials and publications are mentioned. Copyright © 2013. Published by Elsevier SAS.

  10. Assessing Probabilistic Risk Assessment Approaches for Insect Biological Control Introductions.

    PubMed

    Kaufman, Leyla V; Wright, Mark G

    2017-07-07

    The introduction of biological control agents to new environments requires host specificity tests to estimate potential non-target impacts of a prospective agent. Currently, the approach is conservative, and is based on physiological host ranges determined under captive rearing conditions, without consideration for ecological factors that may influence realized host range. We use historical data and current field data from introduced parasitoids that attack an endemic Lepidoptera species in Hawaii to validate a probabilistic risk assessment (PRA) procedure for non-target impacts. We use data on known host range and habitat use in the place of origin of the parasitoids to determine whether contemporary levels of non-target parasitism could have been predicted using PRA. Our results show that reasonable predictions of potential non-target impacts may be made if comprehensive data are available from places of origin of biological control agents, but scant data produce poor predictions. Using apparent mortality data rather than marginal attack rate estimates in PRA resulted in over-estimates of predicted non-target impact. Incorporating ecological data into PRA models improved the predictive power of the risk assessments.

  11. Assessing Probabilistic Risk Assessment Approaches for Insect Biological Control Introductions

    PubMed Central

    Kaufman, Leyla V.; Wright, Mark G.

    2017-01-01

    The introduction of biological control agents to new environments requires host specificity tests to estimate potential non-target impacts of a prospective agent. Currently, the approach is conservative, and is based on physiological host ranges determined under captive rearing conditions, without consideration for ecological factors that may influence realized host range. We use historical data and current field data from introduced parasitoids that attack an endemic Lepidoptera species in Hawaii to validate a probabilistic risk assessment (PRA) procedure for non-target impacts. We use data on known host range and habitat use in the place of origin of the parasitoids to determine whether contemporary levels of non-target parasitism could have been predicted using PRA. Our results show that reasonable predictions of potential non-target impacts may be made if comprehensive data are available from places of origin of biological control agents, but scant data produce poor predictions. Using apparent mortality data rather than marginal attack rate estimates in PRA resulted in over-estimates of predicted non-target impact. Incorporating ecological data into PRA models improved the predictive power of the risk assessments. PMID:28686180

  12. Dynamic conservation of forest genetic resources in 33 European countries.

    PubMed

    Lefèvre, François; Koskela, Jarkko; Hubert, Jason; Kraigher, Hojka; Longauer, Roman; Olrik, Ditte C; Schüler, Silvio; Bozzano, Michele; Alizoti, Paraskevi; Bakys, Remigijus; Baldwin, Cathleen; Ballian, Dalibor; Black-Samuelsson, Sanna; Bednarova, Dagmar; Bordács, Sándor; Collin, Eric; de Cuyper, Bart; de Vries, Sven M G; Eysteinsson, Thröstur; Frýdl, Josef; Haverkamp, Michaela; Ivankovic, Mladen; Konrad, Heino; Koziol, Czesław; Maaten, Tiit; Notivol Paino, Eduardo; Oztürk, Hikmet; Pandeva, Ivanova Denitsa; Parnuta, Gheorghe; Pilipovič, Andrej; Postolache, Dragos; Ryan, Cathal; Steffenrem, Arne; Varela, Maria Carolina; Vessella, Federico; Volosyanchuk, Roman T; Westergren, Marjana; Wolter, Frank; Yrjänä, Leena; Zariŋa, Inga

    2013-04-01

    Dynamic conservation of forest genetic resources (FGR) means maintaining the genetic diversity of trees within an evolutionary process and allowing generation turnover in the forest. We assessed the network of forests areas managed for the dynamic conservation of FGR (conservation units) across Europe (33 countries). On the basis of information available in the European Information System on FGR (EUFGIS Portal), species distribution maps, and environmental stratification of the continent, we developed ecogeographic indicators, a marginality index, and demographic indicators to assess and monitor forest conservation efforts. The pan-European network has 1967 conservation units, 2737 populations of target trees, and 86 species of target trees. We detected a poor coincidence between FGR conservation and other biodiversity conservation objectives within this network. We identified 2 complementary strategies: a species-oriented strategy in which national conservation networks are specifically designed for key target species and a site-oriented strategy in which multiple-target units include so-called secondary species conserved within a few sites. The network is highly unbalanced in terms of species representation, and 7 key target species are conserved in 60% of the conservation units. We performed specific gap analyses for 11 tree species, including assessment of ecogeographic, demographic, and genetic criteria. For each species, we identified gaps, particularly in the marginal parts of their distribution range, and found multiple redundant conservation units in other areas. The Mediterranean forests and to a lesser extent the boreal forests are underrepresented. Monitoring the conservation efficiency of each unit remains challenging; however, <2% of the conserved populations seem to be at risk of extinction. On the basis of our results, we recommend combining species-oriented and site-oriented strategies. © 2012 Society for Conservation Biology.

  13. WE-AB-209-08: Novel Beam-Specific Adaptive Margins for Reducing Organ-At-Risk Doses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsang, H; Kamerling, CP; Ziegenhein, P

    2016-06-15

    Purpose: Current practice of using 3D margins in radiotherapy with high-energy photon beams provides larger-than-required target coverage. According to the photon depth-dose curve, target displacements in beam direction result in minute changes in dose delivered. We exploit this behavior by generating margins on a per-beam basis which simultaneously account for the relative distance of the target and adjacent organs-at-risk (OARs). Methods: For each beam, we consider only geometrical uncertainties of the target location perpendicular to beam direction. By weighting voxels based on its proximity to an OAR, we generate adaptive margins that yield similar overall target coverage probability and reducedmore » OAR dose-burden, at the expense of increased target volume. Three IMRT plans, using 3D margins and 2D per-beam margins with and without adaptation, were generated for five prostate patients with a prescription dose Dpres of 78Gy in 2Gy fractions using identical optimisation constraints. Systematic uncertainties of 1.1, 1.1, 1.5mm in the LR, SI, and AP directions, respectively, and 0.9, 1.1, 1.0mm for the random uncertainties, were assumed. A verification tool was employed to simulate the effects of systematic and random errors using a population size of 50,000. The fraction of the population that satisfies or violates a given DVH constraint was used for comparison. Results: We observe similar target coverage across all plans, with at least 97.5% of the population meeting the D98%>95%Dpres constraint. When looking at the probability of the population receiving D5<70Gy for the rectum, we observed median absolute increases of 23.61% (range, 2.15%–27.85%) and 6.97% (range, 0.65%–17.76%) using per-beam margins with and without adaptation, respectively, relative to using 3D margins. Conclusion: We observed sufficient and similar target coverage using per-beam margins. By adapting each per-beam margin away from an OAR, we can further reduce OAR dose without significantly lowering target coverage probability by irradiating more less-important tissues. This work is supported by Cancer Research UK under Programme C33589/A19908. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR.« less

  14. Optical see-through cancer vision goggles enable direct patient visualization and real-time fluorescence-guided oncologic surgery

    PubMed Central

    Mondal, Suman B.; Gao, Shengkui; Zhu, Nan; Hebimana-Griffin, LeMoyne; Akers, Walter J.; Liang, Rongguang; Gruev, Viktor; Margenthaler, Julie; Achilefu, Samuel

    2017-01-01

    Background The inability to directly visualize the patient and surgical site limits the use of current near infrared fluorescence-guided surgery systems for real-time sentinel lymph node biopsy and tumor margin assessment. Methods We evaluated an optical see-through goggle augmented imaging and navigation system (GAINS) for near-infrared fluorescence-guided surgery. Tumor-bearing mice injected with a near infrared cancer-targeting agent underwent fluorescence-guided tumor resection. Female Yorkshire pigs received hind leg intradermal indocyanine green injection and underwent fluorescence-guided popliteal lymph node resection. Four breast cancer patients received 99mTc-sulfur colloid and indocyanine green retroareolarly, before undergoing sentinel lymph node biopsy using radioactive tracking and fluorescence imaging. Three other breast cancer patients received indocyanine green retroareolarly before undergoing standard-of-care partial mastectomy, followed by fluorescence imaging of resected tumor and tumor cavity for margin assessment. Results Using near-infrared fluorescence from the dyes, the optical see-through GAINS accurately identified all mouse tumors, pig lymphatics, and 4 pig popliteal lymph nodes with high signal-to-background ratio. In 4 human breast cancer patients, 11 sentinel lymph nodes were identified with a detection sensitivity of 86.67± 0.27% for radioactive tracking and 100% for GAINS. Tumor margin status was accurately predicted by GAINS in all three patients, including clear margins in patients 1 and 2 and positive margins in patient 3 as confirmed by paraffin embedded section histopathology. Conclusions The optical see-through GAINS prototype enhances near infrared fluorescence-guided surgery for sentinel lymph node biopsy and tumor margin assessment in breast cancer patients without disrupting the surgical workflow in the operating room. PMID:28213790

  15. Optical See-Through Cancer Vision Goggles Enable Direct Patient Visualization and Real-Time Fluorescence-Guided Oncologic Surgery.

    PubMed

    Mondal, Suman B; Gao, Shengkui; Zhu, Nan; Habimana-Griffin, LeMoyne; Akers, Walter J; Liang, Rongguang; Gruev, Viktor; Margenthaler, Julie; Achilefu, Samuel

    2017-07-01

    The inability to visualize the patient and surgical site directly, limits the use of current near infrared fluorescence-guided surgery systems for real-time sentinel lymph node biopsy and tumor margin assessment. We evaluated an optical see-through goggle augmented imaging and navigation system (GAINS) for near-infrared, fluorescence-guided surgery. Tumor-bearing mice injected with a near infrared cancer-targeting agent underwent fluorescence-guided, tumor resection. Female Yorkshire pigs received hind leg intradermal indocyanine green injection and underwent fluorescence-guided, popliteal lymph node resection. Four breast cancer patients received 99m Tc-sulfur colloid and indocyanine green retroareolarly before undergoing sentinel lymph node biopsy using radioactive tracking and fluorescence imaging. Three other breast cancer patients received indocyanine green retroareolarly before undergoing standard-of-care partial mastectomy, followed by fluorescence imaging of resected tumor and tumor cavity for margin assessment. Using near-infrared fluorescence from the dyes, the optical see-through GAINS accurately identified all mouse tumors, pig lymphatics, and four pig popliteal lymph nodes with high signal-to-background ratio. In 4 human breast cancer patients, 11 sentinel lymph nodes were identified with a detection sensitivity of 86.67 ± 0.27% for radioactive tracking and 100% for GAINS. Tumor margin status was accurately predicted by GAINS in all three patients, including clear margins in patients 1 and 2 and positive margins in patient 3 as confirmed by paraffin-embedded section histopathology. The optical see-through GAINS prototype enhances near infrared fluorescence-guided surgery for sentinel lymph node biopsy and tumor margin assessment in breast cancer patients without disrupting the surgical workflow in the operating room.

  16. A novel probabilistic approach to generating PTV with partial voxel contributions

    NASA Astrophysics Data System (ADS)

    Tsang, H. S.; Kamerling, C. P.; Ziegenhein, P.; Nill, S.; Oelfke, U.

    2017-06-01

    Radiotherapy treatment planning for use with high-energy photon beams currently employs a binary approach in defining the planning target volume (PTV). We propose a margin concept that takes the beam directions into account, generating beam-dependent PTVs (bdPTVs) on a beam-by-beam basis. The resulting degree of overlaps between the bdPTVs are used within the optimisation process; the optimiser effectively considers the same voxel to be both target and organ at risk (OAR) with fractional contributions. We investigate the impact of this novel approach when applied to prostate radiotherapy treatments, and compare treatment plans generated using beam dependent margins to conventional margins. Five prostate patients were used in this planning study, and plans using beam dependent margins improved the sparing of high doses to target-surrounding OARs, though a trade-off in delivering additional low dose to the OARs can be observed. Plans using beam dependent margins are observed to have a slightly reduced target coverage. Nevertheless, all plans are able to satisfy 90% population coverage with the target receiving at least 95% of the prescribed dose to D98% .

  17. Experimental validation of the van Herk margin formula for lung radiation therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ecclestone, Gillian; Heath, Emily; Bissonnette, Jean-Pierre

    2013-11-15

    Purpose: To validate the van Herk margin formula for lung radiation therapy using realistic dose calculation algorithms and respiratory motion modeling. The robustness of the margin formula against variations in lesion size, peak-to-peak motion amplitude, tissue density, treatment technique, and plan conformity was assessed, along with the margin formula assumption of a homogeneous dose distribution with perfect plan conformity.Methods: 3DCRT and IMRT lung treatment plans were generated within the ORBIT treatment planning platform (RaySearch Laboratories, Sweden) on 4DCT datasets of virtual phantoms. Random and systematic respiratory motion induced errors were simulated using deformable registration and dose accumulation tools available withinmore » ORBIT for simulated cases of varying lesion sizes, peak-to-peak motion amplitudes, tissue densities, and plan conformities. A detailed comparison between the margin formula dose profile model, the planned dose profiles, and penumbra widths was also conducted to test the assumptions of the margin formula. Finally, a correction to account for imperfect plan conformity was tested as well as a novel application of the margin formula that accounts for the patient-specific motion trajectory.Results: The van Herk margin formula ensured full clinical target volume coverage for all 3DCRT and IMRT plans of all conformities with the exception of small lesions in soft tissue. No dosimetric trends with respect to plan technique or lesion size were observed for the systematic and random error simulations. However, accumulated plans showed that plan conformity decreased with increasing tumor motion amplitude. When comparing dose profiles assumed in the margin formula model to the treatment plans, discrepancies in the low dose regions were observed for the random and systematic error simulations. However, the margin formula respected, in all experiments, the 95% dose coverage required for planning target volume (PTV) margin derivation, as defined by the ICRU; thus, suitable PTV margins were estimated. The penumbra widths calculated in lung tissue for each plan were found to be very similar to the 6.4 mm value assumed by the margin formula model. The plan conformity correction yielded inconsistent results which were largely affected by image and dose grid resolution while the trajectory modified PTV plans yielded a dosimetric benefit over the standard internal target volumes approach with up to a 5% decrease in the V20 value.Conclusions: The margin formula showed to be robust against variations in tumor size and motion, treatment technique, plan conformity, as well as low tissue density. This was validated by maintaining coverage of all of the derived PTVs by 95% dose level, as required by the formal definition of the PTV. However, the assumption of perfect plan conformity in the margin formula derivation yields conservative margin estimation. Future modifications to the margin formula will require a correction for plan conformity. Plan conformity can also be improved by using the proposed trajectory modified PTV planning approach. This proves especially beneficial for tumors with a large anterior–posterior component of respiratory motion.« less

  18. Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion.

    PubMed

    Acharya, Sahaja; Fischer-Valuck, Benjamin W; Mazur, Thomas R; Curcuru, Austen; Sona, Karl; Kashani, Rojano; Green, Olga; Ochoa, Laura; Mutic, Sasa; Zoberi, Imran; Li, H Harold; Thomas, Maria A

    2016-11-15

    To use magnetic resonance image guided radiation therapy (MR-IGRT) for accelerated partial-breast irradiation (APBI) to (1) determine intrafractional motion of the breast surgical cavity; and (2) assess delivered dose versus planned dose. Thirty women with breast cancer (stages 0-I) who underwent breast-conserving surgery were enrolled in a prospective registry evaluating APBI using a 0.35-T MR-IGRT system. Clinical target volume was defined as the surgical cavity plus a 1-cm margin (excluding chest wall, pectoral muscles, and 5 mm from skin). No additional margin was added for the planning target volume (PTV). A volumetric MR image was acquired before each fraction, and patients were set up to the surgical cavity as visualized on MR imaging. To determine the delivered dose for each fraction, the electron density map and contours from the computed tomography simulation were transferred to the pretreatment MR image via rigid registration. Intrafractional motion of the surgical cavity was determined by applying a tracking algorithm to the cavity contour as visualized on cine MR. Median PTV volume was reduced by 52% when using no PTV margin compared with a 1-cm PTV margin used conventionally. The mean (± standard deviation) difference between planned and delivered dose to the PTV (V95) was 0.6% ± 0.1%. The mean cavity displacement in the anterior-posterior and superior-inferior directions was 0.6 ± 0.4 mm and 0.6 ± 0.3 mm, respectively. The mean margin required for at least 90% of the cavity to be contained by the margin for 90% of the time was 0.7 mm (5th-95th percentile: 0-2.7 mm). Minimal intrafractional motion was observed, and the mean difference between planned and delivered dose was less than 1%. Assessment of efficacy and cosmesis of this MR-guided APBI approach is under way. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Acharya, Sahaja; Fischer-Valuck, Benjamin W.; Mazur, Thomas R.

    Purpose: To use magnetic resonance image guided radiation therapy (MR-IGRT) for accelerated partial-breast irradiation (APBI) to (1) determine intrafractional motion of the breast surgical cavity; and (2) assess delivered dose versus planned dose. Methods and Materials: Thirty women with breast cancer (stages 0-I) who underwent breast-conserving surgery were enrolled in a prospective registry evaluating APBI using a 0.35-T MR-IGRT system. Clinical target volume was defined as the surgical cavity plus a 1-cm margin (excluding chest wall, pectoral muscles, and 5 mm from skin). No additional margin was added for the planning target volume (PTV). A volumetric MR image was acquired beforemore » each fraction, and patients were set up to the surgical cavity as visualized on MR imaging. To determine the delivered dose for each fraction, the electron density map and contours from the computed tomography simulation were transferred to the pretreatment MR image via rigid registration. Intrafractional motion of the surgical cavity was determined by applying a tracking algorithm to the cavity contour as visualized on cine MR. Results: Median PTV volume was reduced by 52% when using no PTV margin compared with a 1-cm PTV margin used conventionally. The mean (± standard deviation) difference between planned and delivered dose to the PTV (V95) was 0.6% ± 0.1%. The mean cavity displacement in the anterior–posterior and superior–inferior directions was 0.6 ± 0.4 mm and 0.6 ± 0.3 mm, respectively. The mean margin required for at least 90% of the cavity to be contained by the margin for 90% of the time was 0.7 mm (5th-95th percentile: 0-2.7 mm). Conclusion: Minimal intrafractional motion was observed, and the mean difference between planned and delivered dose was less than 1%. Assessment of efficacy and cosmesis of this MR-guided APBI approach is under way.« less

  20. Effect of Immobilization and Performance Status on Intrafraction Motion for Stereotactic Lung Radiotherapy: Analysis of 133 Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Winnie, E-mail: winnie.li@rmp.uhn.on.ca; Department of Radiation Oncology, University of Toronto, Toronto, Ontario; Purdie, Thomas G.

    2011-12-01

    Purpose: To assess intrafractional geometric accuracy of lung stereotactic body radiation therapy (SBRT) patients treated with volumetric image guidance. Methods and Materials: Treatment setup accuracy was analyzed in 133 SBRT patients treated via research ethics board-approved protocols. For each fraction, a localization cone-beam computed tomography (CBCT) scan was acquired for soft-tissue registration to the internal target volume, followed by a couch adjustment for positional discrepancies greater than 3 mm, verified with a second CBCT scan. CBCT scans were also performed at intrafraction and end fraction. Patient positioning data from 2047 CBCT scans were recorded to determine systematic ({Sigma}) and randommore » ({sigma}) uncertainties, as well as planning target volume margins. Data were further stratified and analyzed by immobilization method (evacuated cushion [n = 75], evacuated cushion plus abdominal compression [n = 33], or chest board [n = 25]) and by patients' Eastern Cooperative Oncology Group performance status (PS): 0 (n = 31), 1 (n = 70), or 2 (n = 32). Results: Using CBCT internal target volume was matched within {+-}3 mm in 16% of all fractions at localization, 89% at verification, 72% during treatment, and 69% after treatment. Planning target volume margins required to encompass residual setup errors after couch corrections (verification CBCT scans) were 4 mm, and they increased to 5 mm with target intrafraction motion (post-treatment CBCT scans). Small differences (<1 mm) in the cranial-caudal direction of target position were observed between the immobilization cohorts in the localization, verification, intrafraction, and post-treatment CBCT scans (p < 0.01). Positional drift varied according to patient PS, with the PS 1 and 2 cohorts drifting out of position by mid treatment more than the PS 0 cohort in the cranial-caudal direction (p = 0.04). Conclusions: Image guidance ensures high geometric accuracy for lung SBRT irrespective of immobilization method or PS. A 5-mm setup margin suffices to address intrafraction motion. This setup margin may be further reduced by strategies such as frequent image guidance or volumetric arc therapy to correct or limit intrafraction motion.« less

  1. Effect of immobilization and performance status on intrafraction motion for stereotactic lung radiotherapy: analysis of 133 patients.

    PubMed

    Li, Winnie; Purdie, Thomas G; Taremi, Mojgan; Fung, Sharon; Brade, Anthony; Cho, B C John; Hope, Andrew; Sun, Alexander; Jaffray, David A; Bezjak, Andrea; Bissonnette, Jean-Pierre

    2011-12-01

    To assess intrafractional geometric accuracy of lung stereotactic body radiation therapy (SBRT) patients treated with volumetric image guidance. Treatment setup accuracy was analyzed in 133 SBRT patients treated via research ethics board-approved protocols. For each fraction, a localization cone-beam computed tomography (CBCT) scan was acquired for soft-tissue registration to the internal target volume, followed by a couch adjustment for positional discrepancies greater than 3 mm, verified with a second CBCT scan. CBCT scans were also performed at intrafraction and end fraction. Patient positioning data from 2047 CBCT scans were recorded to determine systematic (Σ) and random (σ) uncertainties, as well as planning target volume margins. Data were further stratified and analyzed by immobilization method (evacuated cushion [n=75], evacuated cushion plus abdominal compression [n=33], or chest board [n=25]) and by patients' Eastern Cooperative Oncology Group performance status (PS): 0 (n=31), 1 (n=70), or 2 (n=32). Using CBCT internal target volume was matched within ±3 mm in 16% of all fractions at localization, 89% at verification, 72% during treatment, and 69% after treatment. Planning target volume margins required to encompass residual setup errors after couch corrections (verification CBCT scans) were 4 mm, and they increased to 5 mm with target intrafraction motion (post-treatment CBCT scans). Small differences (<1 mm) in the cranial-caudal direction of target position were observed between the immobilization cohorts in the localization, verification, intrafraction, and post-treatment CBCT scans (p<0.01). Positional drift varied according to patient PS, with the PS 1 and 2 cohorts drifting out of position by mid treatment more than the PS 0 cohort in the cranial-caudal direction (p=0.04). Image guidance ensures high geometric accuracy for lung SBRT irrespective of immobilization method or PS. A 5-mm setup margin suffices to address intrafraction motion. This setup margin may be further reduced by strategies such as frequent image guidance or volumetric arc therapy to correct or limit intrafraction motion. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Margin selection to compensate for loss of target dose coverage due to target motion during external‐beam radiation therapy of the lung

    PubMed Central

    Osei, Ernest; Barnett, Rob

    2015-01-01

    The aim of this study is to provide guidelines for the selection of external‐beam radiation therapy target margins to compensate for target motion in the lung during treatment planning. A convolution model was employed to predict the effect of target motion on the delivered dose distribution. The accuracy of the model was confirmed with radiochromic film measurements in both static and dynamic phantom modes. 502 unique patient breathing traces were recorded and used to simulate the effect of target motion on a dose distribution. A 1D probability density function (PDF) representing the position of the target throughout the breathing cycle was generated from each breathing trace obtained during 4D CT. Changes in the target D95 (the minimum dose received by 95% of the treatment target) due to target motion were analyzed and shown to correlate with the standard deviation of the PDF. Furthermore, the amount of target D95 recovered per millimeter of increased field width was also shown to correlate with the standard deviation of the PDF. The sensitivity of changes in dose coverage with respect to target size was also determined. Margin selection recommendations that can be used to compensate for loss of target D95 were generated based on the simulation results. These results are discussed in the context of clinical plans. We conclude that, for PDF standard deviations less than 0.4 cm with target sizes greater than 5 cm, little or no additional margins are required. Targets which are smaller than 5 cm with PDF standard deviations larger than 0.4 cm are most susceptible to loss of coverage. The largest additional required margin in this study was determined to be 8 mm. PACS numbers: 87.53.Bn, 87.53.Kn, 87.55.D‐, 87.55.Gh

  3. Emergency Department Use Among the Homeless and Marginally Housed: Results From a Community-Based Study

    PubMed Central

    Kushel, Margot B.; Perry, Sharon; Bangsberg, David; Clark, Richard; Moss, Andrew R

    2002-01-01

    Objectives. This study examined factors associated with emergency department use among homeless and marginally housed persons. Methods. Interviews were conducted with 2578 homeless and marginally housed persons, and factors associated with different patterns of emergency department use were assessed in multivariate models. Results. Findings showed that 40.4% of respondents had 1 or more emergency department encounters in the previous year; 7.9% exhibited high rates of use (more than 3 visits) and accounted for 54.5% of all visits. Factors associated with high use rates included less stable housing, victimization, arrests, physical and mental illness, and substance abuse. Predisposing and need factors appeared to drive emergency department use. Conclusions. Efforts to reduce emergency department use among the homeless should be targeted toward addressing underlying risk factors among those exhibiting high rates of use. PMID:11988447

  4. Poster - 36: Effect of Planning Target Volume Coverage on the Dose Delivered in Lung Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dekker, Chris; Wierzbicki, Marcin

    2016-08-15

    Purpose: In lung radiotherapy, breathing motion may be encompassed by contouring the internal target volume (ITV). Remaining uncertainties are included in a geometrical expansion to the planning target volume (PTV). In IMRT, the treatment is then optimized until a desired PTV fraction is covered by the appropriate dose. The resulting beams often carry high fluence in the PTV margin to overcome low lung density and to generate steep dose gradients. During treatment, the high density tumour can enter the PTV margin, potentially increasing target dose. Thus, planning lung IMRT with a reduced PTV dose may still achieve the desired ITVmore » dose during treatment. Methods: A retrospective analysis was carried out with 25 IMRT plans prescribed to 63 Gy in 30 fractions. The plans were re-normalized to cover various fractions of the PTV by different isodose lines. For each case, the isocentre was moved using 125 shifts derived from all 3D combinations of 0 mm, (PTV margin - 1 mm), and PTV margin. After each shift, the dose was recomputed to approximate the delivered dose. Results and Conclusion: Our plans typically cover 95% of the PTV by 95% of the dose. Reducing the PTV covered to 94% did not significantly reduce the delivered ITV doses for (PTV margin - 1 mm) shifts. Target doses were reduced significantly for all other shifts and planning goals studied. Thus, a reduced planning goal will likely deliver the desired target dose as long as the ITV rarely enters the last mm of the PTV margin.« less

  5. Disease Control After Reduced Volume Conformal and Intensity Modulated Radiation Therapy for Childhood Craniopharyngioma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merchant, Thomas E., E-mail: thomas.merchant@stjude.org; Kun, Larry E.; Hua, Chia-Ho

    2013-03-15

    Purpose: To estimate the rate of disease control after conformal radiation therapy using reduced clinical target volume (CTV) margins and to determine factors that predict for tumor progression. Methods and Materials: Eighty-eight children (median age, 8.5 years; range, 3.2-17.6 years) received conformal or intensity modulated radiation therapy between 1998 and 2009. The study group included those prospectively treated from 1998 to 2003, using a 10-mm CTV, defined as the margin surrounding the solid and cystic tumor targeted to receive the prescription dose of 54 Gy. The CTV margin was subsequently reduced after 2003, yielding 2 groups of patients: those treatedmore » with a CTV margin greater than 5 mm (n=26) and those treated with a CTV margin less than or equal to 5 mm (n=62). Disease progression was estimated on the basis of additional variables including sex, race, extent of resection, tumor interventions, target volume margins, and frequency of weekly surveillance magnetic resonance (MR) imaging during radiation therapy. Median follow-up was 5 years. Results: There was no difference between progression-free survival rates based on CTV margins (>5 mm vs ≤5 mm) at 5 years (88.1% ± 6.3% vs 96.2% ± 4.4% [P=.6386]). There were no differences based on planning target volume (PTV) margins (or combined CTV plus PTV margins). The PTV was systematically reduced from 5 to 3 mm during the time period of the study. Factors predictive of superior progression-free survival included Caucasian race (P=.0175), no requirement for cerebrospinal fluid shunting (P=.0066), and number of surveillance imaging studies during treatment (P=.0216). Patients whose treatment protocol included a higher number of weekly surveillance MR imaging evaluations had a lower rate of tumor progression. Conclusions: These results suggest that targeted volume reductions for radiation therapy using smaller margins are feasible and safe but require careful monitoring. We are currently investigating the differences in outcome based on host factors to explain the results.« less

  6. Hierarchical Marginal Land Assessment for Land Use Planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kang, Shujiang; Post, Wilfred M; Wang, Dali

    2013-01-01

    Marginal land provides an alternative potential for food and bioenergy production in the face of limited land resources; however, effective assessment of marginal lands is not well addressed. Concerns over environmental risks, ecosystem services and sustainability for marginal land have been widely raised. The objective of this study was to develop a hierarchical marginal land assessment framework for land use planning and management. We first identified major land functions linking production, environment, ecosystem services and economics, and then classified land resources into four categories of marginal land using suitability and limitations associated with major management goals, including physically marginal land,more » biologically marginal land, environmental-ecological marginal land, and economically marginal land. We tested this assessment framework in south-western Michigan, USA. Our results indicated that this marginal land assessment framework can be potentially feasible on land use planning for food and bioenergy production, and balancing multiple goals of land use management. We also compared our results with marginal land assessment from the Conservation Reserve Program (CRP) and land capability classes (LCC) that are used in the US. The hierarchical assessment framework has advantages of quantitatively reflecting land functions and multiple concerns. This provides a foundation upon which focused studies can be identified in order to improve the assessment framework by quantifying high-resolution land functions associated with environment and ecosystem services as well as their criteria are needed to improve the assessment framework.« less

  7. Calculating radiotherapy margins based on Bayesian modelling of patient specific random errors

    NASA Astrophysics Data System (ADS)

    Herschtal, A.; te Marvelde, L.; Mengersen, K.; Hosseinifard, Z.; Foroudi, F.; Devereux, T.; Pham, D.; Ball, D.; Greer, P. B.; Pichler, P.; Eade, T.; Kneebone, A.; Bell, L.; Caine, H.; Hindson, B.; Kron, T.

    2015-02-01

    Collected real-life clinical target volume (CTV) displacement data show that some patients undergoing external beam radiotherapy (EBRT) demonstrate significantly more fraction-to-fraction variability in their displacement (‘random error’) than others. This contrasts with the common assumption made by historical recipes for margin estimation for EBRT, that the random error is constant across patients. In this work we present statistical models of CTV displacements in which random errors are characterised by an inverse gamma (IG) distribution in order to assess the impact of random error variability on CTV-to-PTV margin widths, for eight real world patient cohorts from four institutions, and for different sites of malignancy. We considered a variety of clinical treatment requirements and penumbral widths. The eight cohorts consisted of a total of 874 patients and 27 391 treatment sessions. Compared to a traditional margin recipe that assumes constant random errors across patients, for a typical 4 mm penumbral width, the IG based margin model mandates that in order to satisfy the common clinical requirement that 90% of patients receive at least 95% of prescribed RT dose to the entire CTV, margins be increased by a median of 10% (range over the eight cohorts -19% to +35%). This substantially reduces the proportion of patients for whom margins are too small to satisfy clinical requirements.

  8. A novel method to quantify and compare anatomical shape: application in cervix cancer radiotherapy

    NASA Astrophysics Data System (ADS)

    Oh, Seungjong; Jaffray, David; Cho, Young-Bin

    2014-06-01

    Adaptive radiation therapy (ART) had been proposed to restore dosimetric deficiencies during treatment delivery. In this paper, we developed a technique of Geometric reLocation for analyzing anatomical OBjects' Evolution (GLOBE) for a numerical model of tumor evolution under radiation therapy and characterized geometric changes of the target using GLOBE. A total of 174 clinical target volumes (CTVs) obtained from 32 cervical cancer patients were analyzed. GLOBE consists of three main steps; step (1) deforming a 3D surface object to a sphere by parametric active contour (PAC), step (2) sampling a deformed PAC on 642 nodes of icosahedron geodesic dome for reference frame, and step (3) unfolding 3D data to 2D plane for convenient visualization and analysis. The performance was evaluated with respect to (1) convergence of deformation (iteration number and computation time) and (2) accuracy of deformation (residual deformation). Based on deformation vectors from planning CTV to weekly CTVs, target specific (TS) margins were calculated on each sampled node of GLOBE and the systematic (Σ) and random (σ) variations of the vectors were calculated. Population based anisotropic (PBA) margins were generated using van Herk's margin recipe. GLOBE successfully modeled 152 CTVs from 28 patients. Fast convergence was observed for most cases (137/152) with the iteration number of 65 ± 74 (average ± STD) and the computation time of 13.7 ± 18.6 min. Residual deformation of PAC was 0.9 ± 0.7 mm and more than 97% was less than 3 mm. Margin analysis showed random nature of TS-margin. As a consequence, PBA-margins perform similarly to ISO-margins. For example, PBA-margins for 90% patients' coverage with 95% dose level is close to 13 mm ISO-margins in the aspect of target coverage and OAR sparing. GLOBE demonstrates a systematic analysis of tumor motion and deformation of patients with cervix cancer during radiation therapy and numerical modeling of PBA-margin on 642 locations of CTV surface.

  9. Sustainable biomass production on Marginal Lands (SEEMLA)

    NASA Astrophysics Data System (ADS)

    Barbera, Federica; Baumgarten, Wibke; Pelikan, Vincent

    2017-04-01

    Sustainable biomass production on Marginal Lands (SEEMLA) The main objective of the H2020 funded EU project SEEMLA (acronym for Sustainable Exploitation of Biomass for Bioenergy from Marginal Lands in Europe) is the establishment of suitable innovative land-use strategies for a sustainable production of plant-based energy on marginal lands while improving general ecosystem services. The use of marginal lands (MagL) could contribute to the mitigation of the fast growing competition between traditional food production and production of renewable bio-resources on arable lands. SEEMLA focuses on the promotion of re-conversion of MagLs for the production of bioenergy through the direct involvement of farmers and forester, the strengthening of local small-scale supply chains, and the promotion of plantations of bioenergy plants on MagLs. Life cycle assessment is performed in order to analyse possible impacts on the environment. A soil quality rating tool is applied to define and classify MagL. Suitable perennial and woody bioenergy crops are selected to be grown in pilot areas in the partner countries Ukraine, Greece and Germany. SEEMLA is expected to contribute to an increasing demand of biomass for bioenergy production in order to meet the 2020 targets and beyond.

  10. Marginal Lands: Concept, Assessment and Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kang, Shujiang; Post, Wilfred M; West, Tristram O.

    2013-01-01

    Marginal lands have received wide attention for their potential to improve food security and support bioenergy production. However, environmental, ecosystem service, and sustainability concerns have been widely raised over the use of marginal land. Knowledge of the extent, location, and quality of marginal lands as well as their assessment and management are limited and diverse. This paper provides a review of the historical development of marginal concept, its application and assessment. Limitations and priority research needs of marginal land assessment and management were discussed.

  11. Evaluation of the setup margins for cone beam computed tomography–guided cranial radiosurgery: A phantom study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Calvo Ortega, Juan Francisco, E-mail: jfcdrr@yahoo.es; Wunderink, Wouter; Delgado, David

    The aim of this study is to evaluate the setup margins from the clinical target volume (CTV) to planning target volume (PTV) for cranial stereotactic radiosurgery (SRS) treatments guided by cone beam computed tomography (CBCT). We designed an end-to-end (E2E) test using a skull phantom with an embedded 6mm tungsten ball (target). A noncoplanar plan was computed (E2E plan) to irradiate the target. The CBCT-guided positioning of the skull phantom on the linac was performed. Megavoltage portal images were acquired after 15 independent deliveries of the E2E plan. The displacement 2-dimensional (2D) vector between the centers of the square fieldmore » and the ball target on each portal image was used to quantify the isocenter accuracy. Geometrical margins on each patient's direction (left-right or LR, anterior-posterior or AP, superior-inferior or SI) were calculated. Dosimetric validation of the margins was performed in 5 real SRS cases: 3-dimesional (3D) isocenter deviations were mimicked, and changes in CTV dose coverage and organs-at-risk (OARs) dosage were analyzed. The CTV-PTV margins of 1.1 mm in LR direction, and 0.7 mm in AP and SI directions were derived from the E2E tests. The dosimetric analysis revealed that a 1-mm uniform margin was sufficient to ensure the CTV dose coverage, without compromising the OAR dose tolerances. The effect of isocenter uncertainty has been estimated to be 1 mm in our CBCT-guided SRS approach.« less

  12. Assessment of three-dimensional setup errors in image-guided pelvic radiotherapy for uterine and cervical cancer using kilovoltage cone-beam computed tomography and its effect on planning target volume margins.

    PubMed

    Patni, Nidhi; Burela, Nagarjuna; Pasricha, Rajesh; Goyal, Jaishree; Soni, Tej Prakash; Kumar, T Senthil; Natarajan, T

    2017-01-01

    To achieve the best possible therapeutic ratio using high-precision techniques (image-guided radiation therapy/volumetric modulated arc therapy [IGRT/VMAT]) of external beam radiation therapy in cases of carcinoma cervix using kilovoltage cone-beam computed tomography (kV-CBCT). One hundred and five patients of gynecological malignancies who were treated with IGRT (IGRT/VMAT) were included in the study. CBCT was done once a week for intensity-modulated radiation therapy and daily in IGRT/VMAT. These images were registered with the planning CT scan images and translational errors were applied and recorded. In all, 2078 CBCT images were studied. The margins of planning target volume were calculated from the variations in the setup. The setup variation was 5.8, 10.3, and 5.6 mm in anteroposterior, superoinferior, and mediolateral direction. This allowed adequate dose delivery to the clinical target volume and the sparing of organ at risks. Daily kV-CBCT is a satisfactory method of accurate patient positioning in treating gynecological cancers with high-precision techniques. This resulted in avoiding geographic miss.

  13. Targeting Lynch Victims: Social Marginality or Status Transgressions?

    PubMed

    Bailey, Amy Kate; Tolnay, Stewart E; Beck, E M; Laird, Jennifer D

    2011-06-01

    This paper presents the first evidence yielded by a newly-compiled database of known lynch victims. Using information from the original census enumerators' manuscripts, we identify the individual- and household-level characteristics of more than 900 black males lynched in ten southern states between 1882 and 1930. First, we use the information gathered for successfully linked cases to present a profile of individual-level and household-level characteristics of a large sample of lynch victims. Second, we compare these characteristics to a randomly-generated sample of black men living in the counties where lynchings occurred. We use our findings from this comparative analysis to assess the empirical support for alternative theoretical perspectives on the selection of individuals as victims of southern mob violence. Third, we consider whether the individual-level risk factors for being targeted as a lynch victim varied substantially over time or across space. Our results demonstrate that victims were generally less embedded within the social and economic fabric of their communities than were other black men, suggesting that social marginality increased the likelihood of being targeted for lynching. These findings were generally consistent across decades, and within different socio-demographic contexts.

  14. Personal Control and Service Connection as Paths to Improved Mental Health and Exiting Homelessness among Severely Marginalized Homeless Youth.

    PubMed

    Slesnick, Natasha; Zhang, Jing; Brakenhoff, Brittany

    2017-02-01

    Non-service connected, continuously homeless youth are arguably one of the most vulnerable populations in the U.S. These youth reside at society's margins experiencing an accumulation of risks over time. Research concludes that as vulnerabilities increase so do poor long-term outcomes. This study tested the mediating effects of service connection and personal control as mediators of cumulative risk and housing, health and mental health outcomes. By understanding the processes associated with therapeutic change among those with the most vulnerabilities, service providers and researchers can target those factors to enhance positive outcomes. Seventy-nine, non-service connected, substance using homeless youth were offered a strengths-based outreach and engagement intervention and were assessed at baseline 3, 6 and 9 months post-baseline. Personal control mediated the effects of cumulative risk on housing stability, and service utilization mediated the effects of cumulative risk on mental health. This study specifies important targets of intervention for a population at high risk for continuing homelessness. In particular, service providers should target youths' sense of personal control and link them to needed community-based services in order to help them exit street life and improve mental health outcomes.

  15. Effect of Patient Set-up and Respiration motion on Defining Biological Targets for Image-Guided Targeted Radiotherapy

    NASA Astrophysics Data System (ADS)

    McCall, Keisha C.

    Identification and monitoring of sub-tumor targets will be a critical step for optimal design and evaluation of cancer therapies in general and biologically targeted radiotherapy (dose-painting) in particular. Quantitative PET imaging may be an important tool for these applications. Currently radiotherapy planning accounts for tumor motion by applying geometric margins. These margins create a motion envelope to encompass the most probable positions of the tumor, while also maintaining the appropriate tumor control and normal tissue complication probabilities. This motion envelope is effective for uniform dose prescriptions where the therapeutic dose is conformed to the external margins of the tumor. However, much research is needed to establish the equivalent margins for non-uniform fields, where multiple biological targets are present and each target is prescribed its own dose level. Additionally, the size of the biological targets and close proximity make it impractical to apply planning margins on the sub-tumor level. Also, the extent of high dose regions must be limited to avoid excessive dose to the surrounding tissue. As such, this research project is an investigation of the uncertainty within quantitative PET images of moving and displaced dose-painting targets, and an investigation of the residual errors that remain after motion management. This included characterization of the changes in PET voxel-values as objects are moved relative to the discrete sampling interval of PET imaging systems (SPECIFIC AIM 1). Additionally, the repeatability of PET distributions and the delineating dose-painting targets were measured (SPECIFIC AIM 2). The effect of imaging uncertainty on the dose distributions designed using these images (SPECIFIC AIM 3) has also been investigated. This project also included analysis of methods to minimize motion during PET imaging and reduce the dosimetric impact of motion/position-induced imaging uncertainty (SPECIFIC AIM 4).

  16. Treating locally advanced lung cancer with a 1.5T MR-Linac - Effects of the magnetic field and irradiation geometry on conventionally fractionated and isotoxic dose-escalated radiotherapy.

    PubMed

    Bainbridge, Hannah E; Menten, Martin J; Fast, Martin F; Nill, Simeon; Oelfke, Uwe; McDonald, Fiona

    2017-11-01

    This study investigates the feasibility and potential benefits of radiotherapy with a 1.5T MR-Linac for locally advanced non-small cell lung cancer (LA NSCLC) patients. Ten patients with LA NSCLC were retrospectively re-planned six times: three treatment plans were created according to a protocol for conventionally fractionated radiotherapy and three treatment plans following guidelines for isotoxic target dose escalation. In each case, two plans were designed for the MR-Linac, either with standard (∼7mm) or reduced (∼3mm) planning target volume (PTV) margins, while one conventional linac plan was created with standard margins. Treatment plan quality was evaluated using dose-volume metrics or by quantifying dose escalation potential. All generated treatment plans fulfilled their respective planning constraints. For conventionally fractionated treatments, MR-Linac plans with standard margins had slightly increased skin dose when compared to conventional linac plans. Using reduced margins alleviated this issue and decreased exposure of several other organs-at-risk (OAR). Reduced margins also enabled increased isotoxic target dose escalation. It is feasible to generate treatment plans for LA NSCLC patients on a 1.5T MR-Linac. Margin reduction, facilitated by an envisioned MRI-guided workflow, enables increased OAR sparing and isotoxic target dose escalation for the respective treatment approaches. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  17. The effect of uterine motion and uterine margins on target and normal tissue doses in intensity modulated radiation therapy of cervical cancer

    NASA Astrophysics Data System (ADS)

    Gordon, J. J.; Weiss, E.; Abayomi, O. K.; Siebers, J. V.; Dogan, N.

    2011-05-01

    In intensity modulated radiation therapy (IMRT) of cervical cancer, uterine motion can be larger than cervix motion, requiring a larger clinical target volume to planning target volume (CTV-to-PTV) margin around the uterine fundus. This work simulates different motion models and margins to estimate the dosimetric consequences. A virtual study used image sets from ten patients. Plans were created with uniform margins of 1 cm (PTVA) and 2.4 cm (PTVC), and a margin tapering from 2.4 cm at the fundus to 1 cm at the cervix (PTVB). Three inter-fraction motion models (MM) were simulated. In MM1, all structures moved with normally distributed rigid body translations. In MM2, CTV motion was progressively magnified as one moved superiorly from the cervix to the fundus. In MM3, both CTV and normal tissue motion were magnified as in MM2, modeling the scenario where normal tissues move into the void left by the mobile uterus. Plans were evaluated using static and percentile DVHs. For a conventional margin (PTVA), quasi-realistic uterine motion (MM3) reduces fundus dose by about 5 Gy and increases normal tissue volumes receiving 30-50 Gy by ~5%. A tapered CTV-to-PTV margin can restore fundus and CTV doses, but will increase normal tissue volumes receiving 30-50 Gy by a further ~5%.

  18. Estimation of daily interfractional larynx residual setup error after isocentric alignment for head and neck radiotherapy: Quality-assurance implications for target volume and organ-at-risk margination using daily CT-on-rails imaging

    PubMed Central

    Baron, Charles A.; Awan, Musaddiq J.; Mohamed, Abdallah S. R.; Akel, Imad; Rosenthal, David I.; Gunn, G. Brandon; Garden, Adam S.; Dyer, Brandon A.; Court, Laurence; Sevak, Parag R; Kocak-Uzel, Esengul; Fuller, Clifton D.

    2016-01-01

    Larynx may alternatively serve as a target or organ-at-risk (OAR) in head and neck cancer (HNC) image-guided radiotherapy (IGRT). The objective of this study was to estimate IGRT parameters required for larynx positional error independent of isocentric alignment and suggest population–based compensatory margins. Ten HNC patients receiving radiotherapy (RT) with daily CT-on-rails imaging were assessed. Seven landmark points were placed on each daily scan. Taking the most superior anterior point of the C5 vertebra as a reference isocenter for each scan, residual displacement vectors to the other 6 points were calculated post-isocentric alignment. Subsequently, using the first scan as a reference, the magnitude of vector differences for all 6 points for all scans over the course of treatment were calculated. Residual systematic and random error, and the necessary compensatory CTV-to-PTV and OAR-to-PRV margins were calculated, using both observational cohort data and a bootstrap-resampled population estimator. The grand mean displacements for all anatomical points was 5.07mm, with mean systematic error of 1.1mm and mean random setup error of 2.63mm, while bootstrapped POIs grand mean displacement was 5.09mm, with mean systematic error of 1.23mm and mean random setup error of 2.61mm. Required margin for CTV-PTV expansion was 4.6mm for all cohort points, while the bootstrap estimator of the equivalent margin was 4.9mm. The calculated OAR-to-PRV expansion for the observed residual set-up error was 2.7mm, and bootstrap estimated expansion of 2.9mm. We conclude that the interfractional larynx setup error is a significant source of RT set-up/delivery error in HNC both when the larynx is considered as a CTV or OAR. We estimate the need for a uniform expansion of 5mm to compensate for set up error if the larynx is a target or 3mm if the larynx is an OAR when using a non-laryngeal bony isocenter. PMID:25679151

  19. Estimation of daily interfractional larynx residual setup error after isocentric alignment for head and neck radiotherapy: quality assurance implications for target volume and organs‐at‐risk margination using daily CT on‐rails imaging

    PubMed Central

    Baron, Charles A.; Awan, Musaddiq J.; Mohamed, Abdallah S.R.; Akel, Imad; Rosenthal, David I.; Gunn, G. Brandon; Garden, Adam S.; Dyer, Brandon A.; Court, Laurence; Sevak, Parag R.; Kocak‐Uzel, Esengul

    2014-01-01

    Larynx may alternatively serve as a target or organs at risk (OAR) in head and neck cancer (HNC) image‐guided radiotherapy (IGRT). The objective of this study was to estimate IGRT parameters required for larynx positional error independent of isocentric alignment and suggest population‐based compensatory margins. Ten HNC patients receiving radiotherapy (RT) with daily CT on‐rails imaging were assessed. Seven landmark points were placed on each daily scan. Taking the most superior‐anterior point of the C5 vertebra as a reference isocenter for each scan, residual displacement vectors to the other six points were calculated postisocentric alignment. Subsequently, using the first scan as a reference, the magnitude of vector differences for all six points for all scans over the course of treatment was calculated. Residual systematic and random error and the necessary compensatory CTV‐to‐PTV and OAR‐to‐PRV margins were calculated, using both observational cohort data and a bootstrap‐resampled population estimator. The grand mean displacements for all anatomical points was 5.07 mm, with mean systematic error of 1.1 mm and mean random setup error of 2.63 mm, while bootstrapped POIs grand mean displacement was 5.09 mm, with mean systematic error of 1.23 mm and mean random setup error of 2.61 mm. Required margin for CTV‐PTV expansion was 4.6 mm for all cohort points, while the bootstrap estimator of the equivalent margin was 4.9 mm. The calculated OAR‐to‐PRV expansion for the observed residual setup error was 2.7 mm and bootstrap estimated expansion of 2.9 mm. We conclude that the interfractional larynx setup error is a significant source of RT setup/delivery error in HNC, both when the larynx is considered as a CTV or OAR. We estimate the need for a uniform expansion of 5 mm to compensate for setup error if the larynx is a target, or 3 mm if the larynx is an OAR, when using a nonlaryngeal bony isocenter. PACS numbers: 87.55.D‐, 87.55.Qr

  20. Evaluation of target coverage and margins adequacy during CyberKnife Lung Optimized Treatment.

    PubMed

    Ricotti, Rosalinda; Seregni, Matteo; Ciardo, Delia; Vigorito, Sabrina; Rondi, Elena; Piperno, Gaia; Ferrari, Annamaria; Zerella, Maria Alessia; Arculeo, Simona; Francia, Claudia Maria; Sibio, Daniela; Cattani, Federica; De Marinis, Filippo; Spaggiari, Lorenzo; Orecchia, Roberto; Riboldi, Marco; Baroni, Guido; Jereczek-Fossa, Barbara Alicja

    2018-04-01

    Evaluation of target coverage and verification of safety margins, in motion management strategies implemented by Lung Optimized Treatment (LOT) module in CyberKnife system. Three fiducial-less motion management strategies provided by LOT can be selected according to tumor visibility in the X ray images acquired during treatment. In 2-view modality the tumor is visible in both X ray images and full motion tracking is performed. In 1-view modality the tumor is visible in a single X ray image, therefore, motion tracking is combined with an internal target volume (ITV)-based margin expansion. In 0-view modality the lesion is not visible, consequently the treatment relies entirely on an ITV-based approach. Data from 30 patients treated in 2-view modality were selected providing information on the three-dimensional tumor motion in correspondence to each X ray image. Treatments in 1-view and 0-view modalities were simulated by processing log files and planning volumes. Planning target volume (PTV) margins were defined according to the tracking modality: end-exhale clinical target volume (CTV) + 3 mm in 2-view and ITV + 5 mm in 0-view. In the 1-view scenario, the ITV encompasses only tumor motion along the non-visible direction. Then, non-uniform ITV to PTV margins were applied: 3 mm and 5 mm in the visible and non-visible direction, respectively. We defined the coverage of each voxel of the CTV as the percentage of X ray images where such voxel was included in the PTV. In 2-view modality coverage was calculated as the intersection between the CTV centred on the imaged target position and the PTV centred on the predicted target position, as recorded in log files. In 1-view modality, coverage was calculated as the intersection between the CTV centred on the imaged target position and the PTV centred on the projected predictor data. In 0-view modality coverage was calculated as the intersection between the CTV centred on the imaged target position and the non-moving PTV. Similar to dose-volume histogram, CTV coverage-volume histograms (defined as CVH) were derived for each patient and treatment modality. The geometric coverages of the 90% and 95% of CTV volume (C90, C95, respectively) were evaluated. Patient-specific optimal margins (ensuring C95 ≥ 95%) were computed retrospectively. The median ± interquartile-rage of C90 and C95 for upper lobe lesions was 99.1 ± 0.6% and 99.0 ± 3.1%, whereas they were 98.9 ± 4.2% and 97.8 ± 7.5% for lower and middle lobe tumors. In 2-view, 1-view and 0-view modality, adopted margins ensured C95 ≥ 95% in 70%, 85% and 63% of cases and C95 ≥ 90% in 90%, 88% and 83% of cases, respectively. In 2-view, 1-view and 0-view a reduction in margins still ensured C95 ≥ 95% in 33%, 78% and 59% of cases, respectively. CTV coverage analysis provided an a-posteriori evaluation of the treatment geometric accuracy and allowed a quantitative verification of the adequacy of the PTV margins applied in CyberKnife LOT treatments offering guidance in the selection of CTV margins. © 2018 American Association of Physicists in Medicine.

  1. Dosimetric evaluation of planning target volume margin reduction for prostate cancer via image-guided intensity-modulated radiation therapy

    NASA Astrophysics Data System (ADS)

    Hwang, Taejin; Kang, Sei-Kwon; Cheong, Kwang-Ho; Park, Soah; Yoon, Jai-Woong; Han, Taejin; Kim, Haeyoung; Lee, Meyeon; Kim, Kyoung-Joo; Bae, Hoonsik; Suh, Tae-Suk

    2015-07-01

    The aim of this study was to quantitatively estimate the dosimetric benefits of the image-guided radiation therapy (IGRT) system for the prostate intensity-modulated radiation therapy (IMRT) delivery. The cases of eleven patients who underwent IMRT for prostate cancer without a prostatectomy at our institution between October 2012 and April 2014 were retrospectively analyzed. For every patient, clinical target volume (CTV) to planning target volume (PTV) margins were uniformly used: 3 mm, 5 mm, 7 mm, 10 mm, 12 mm, and 15 mm. For each margin size, the IMRT plans were independently optimized by one medical physicist using Pinnalce3 (ver. 8.0.d, Philips Medical System, Madison, WI) in order to maintain the plan quality. The maximum geometrical margin (MGM) for every CT image set, defined as the smallest margin encompassing the rectum at least at one slice, was between 13 mm and 26 mm. The percentage rectum overlapping PTV (%V ROV ), the rectal normal tissue complication probability (NTCP) and the mean rectal dose (%RD mean ) increased in proportion to the increase of PTV margin. However the bladder NTCP remained around zero to some extent regardless of the increase of PTV margin while the percentage bladder overlapping PTV (%V BOV ) and the mean bladder dose (%BD mean ) increased in proportion to the increase of PTV margin. Without relatively large rectum or small bladder, the increase observed for rectal NTCP, %RDmean and %BD mean per 1-mm PTV margin size were 1.84%, 2.44% and 2.90%, respectively. Unlike the behavior of the rectum or the bladder, the maximum dose on each femoral head had little effect on PTV margin. This quantitative study of the PTV margin reduction supported that IG-IMRT has enhanced the clinical effects over prostate cancer with the reduction of normal organ complications under the similar level of PTV control.

  2. An experimental assessment of physical educators' expectations and attitudes: the importance of student weight and gender.

    PubMed

    Peterson, Jamie Lee; Puhl, Rebecca M; Luedicke, Joerg

    2012-09-01

    At school, physical education (PE) teachers and coaches may be key supports for physical activity. Unfortunately, PE teachers may endorse negative stereotypes and attitudes toward overweight youth. These biases may influence the amount of instruction physical educators provide to students and their participation in PE or other physical activity. This study assessed physical educators' (N = 162) ability and performance expectations, attributions, and attitudes toward overweight and non-overweight students. Physical educators endorsed inferior ability expectations for overweight students compared to non-overweight students. Poorer performance expectations were limited to overweight female targets, but when controlling for participant characteristics, this effect became marginally significant for overweight male targets. There was a trend such that participants endorsed more external attributions for the abilities and performance of overweight female students, yet this effect was reduced to marginal significance when controlling for participant characteristics. Participants endorsed more negative attitudes for both overweight males and females compared to non-overweight youth. Findings indicate that physical educators' expectations, attributions, and attitudes regarding students may be negatively influenced by youth body weight, and differ by student gender. The potential effect of physical educators' weight bias on adolescent participation in physical activity and its implications for students' physical health, academic achievement, and social development are discussed. © 2012, American School Health Association.

  3. Set-up uncertainties: online correction with X-ray volume imaging.

    PubMed

    Kataria, Tejinder; Abhishek, Ashu; Chadha, Pranav; Nandigam, Janardhan

    2011-01-01

    To determine interfractional three-dimensional set-up errors using X-ray volumetric imaging (XVI). Between December 2007 and August 2009, 125 patients were taken up for image-guided radiotherapy using online XVI. After matching of reference and acquired volume view images, set-up errors in three translation directions were recorded and corrected online before treatment each day. Mean displacements, population systematic (Σ), and random (σ) errors were calculated and analyzed using SPSS (v16) software. Optimum clinical target volume (CTV) to planning target volume (PTV) margin was calculated using Van Herk's (2.5Σ + 0.7 σ) and Stroom's (2Σ + 0.7 σ) formula. Patients were grouped in 4 cohorts, namely brain, head and neck, thorax, and abdomen-pelvis. The mean vector displacement recorded were 0.18 cm, 0.15 cm, 0.36 cm, and 0.35 cm for brain, head and neck, thorax, and abdomen-pelvis, respectively. Analysis of individual mean set-up errors revealed good agreement with the proposed 0.3 cm isotropic margins for brain and 0.5 cm isotropic margins for head-neck. Similarly, 0.5 cm circumferential and 1 cm craniocaudal proposed margins were in agreement with thorax and abdomen-pelvic cases. The calculated mean displacements were well within CTV-PTV margin estimates of Van Herk (90% population coverage to minimum 95% prescribed dose) and Stroom (99% target volume coverage by 95% prescribed dose). Employing these individualized margins in a particular cohort ensure comparable target coverage as described in literature, which is further improved if XVI-aided set-up error detection and correction is used before treatment.

  4. Bioenergy crop productivity and potential climate change mitigation from marginal lands in the United States: An ecosystem modeling perspective

    DOE PAGES

    Qin, Zhangcai; Zhuang, Qianlai; Cai, Ximing

    2014-06-16

    Growing biomass feedstocks from marginal lands is becoming an increasingly attractive choice for producing biofuel as an alternative energy to fossil fuels. Here, we used a biogeochemical model at ecosystem scale to estimate crop productivity and greenhouse gas (GHG) emissions from bioenergy crops grown on marginal lands in the United States. Two broadly tested cellulosic crops, switchgrass, and Miscanthus, were assumed to be grown on the abandoned land and mixed crop–vegetation land with marginal productivity. Production of biomass and biofuel as well as net carbon exchange and nitrous oxide emissions were estimated in a spatially explicit manner. We found that,more » cellulosic crops, especially Miscanthus could produce a considerable amount of biomass, and the effective ethanol yield is high on these marginal lands. For every hectare of marginal land, switchgrass and Miscanthus could produce 1.0–2.3 kl and 2.9–6.9 kl ethanol, respectively, depending on nitrogen fertilization rate and biofuel conversion efficiency. Nationally, both crop systems act as net GHG sources. Switchgrass has high global warming intensity (100–390 g CO 2eq l –1 ethanol), in terms of GHG emissions per unit ethanol produced. Miscanthus, however, emits only 21–36 g CO 2eq to produce every liter of ethanol. To reach the mandated cellulosic ethanol target in the United States, growing Miscanthus on the marginal lands could potentially save land and reduce GHG emissions in comparison to growing switchgrass. Furthermore, the ecosystem modeling is still limited by data availability and model deficiencies, further efforts should be made to classify crop–specific marginal land availability, improve model structure, and better integrate ecosystem modeling into life cycle assessment.« less

  5. Radiobiological Impact of Reduced Margins and Treatment Technique for Prostate Cancer in Terms of Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jensen, Ingelise, E-mail: inje@rn.d; Carl, Jesper; Lund, Bente

    2011-07-01

    Dose escalation in prostate radiotherapy is limited by normal tissue toxicities. The aim of this study was to assess the impact of margin size on tumor control and side effects for intensity-modulated radiation therapy (IMRT) and 3D conformal radiotherapy (3DCRT) treatment plans with increased dose. Eighteen patients with localized prostate cancer were enrolled. 3DCRT and IMRT plans were compared for a variety of margin sizes. A marker detectable on daily portal images was presupposed for narrow margins. Prescribed dose was 82 Gy within 41 fractions to the prostate clinical target volume (CTV). Tumor control probability (TCP) calculations based on themore » Poisson model including the linear quadratic approach were performed. Normal tissue complication probability (NTCP) was calculated for bladder, rectum and femoral heads according to the Lyman-Kutcher-Burman method. All plan types presented essentially identical TCP values and very low NTCP for bladder and femoral heads. Mean doses for these critical structures reached a minimum for IMRT with reduced margins. Two endpoints for rectal complications were analyzed. A marked decrease in NTCP for IMRT plans with narrow margins was seen for mild RTOG grade 2/3 as well as for proctitis/necrosis/stenosis/fistula, for which NTCP <7% was obtained. For equivalent TCP values, sparing of normal tissue was demonstrated with the narrow margin approach. The effect was more pronounced for IMRT than 3DCRT, with respect to NTCP for mild, as well as severe, rectal complications.« less

  6. Marginal abatement cost curves for NOx incorporating both controls and alternative measures

    EPA Science Inventory

    A marginal abatement cost curve (MACC) traces out the efficient marginal abatement cost level for any aggregate emissions target when a least cost approach is implemented. In order for it to represent the efficient MAC level, all abatement opportunities across all sectors and loc...

  7. Approaches for grouping of pesticides into cumulative assessment groups for risk assessment of pesticide residues in food.

    PubMed

    Colnot, Thomas; Dekant, Wolfgang

    2017-02-01

    The European Food Safety Authority (EFSA) is developing approaches to cumulative risk assessment of pesticides by assigning individual pesticides to cumulative assessment groups (CAGs). For assignment to CAGs, EFSA recommended to rely on adverse effects on the specific target system. Contractors to EFSA have proposed to allocate individual pesticides into CAGs relying on NOAELs for effects on target organs. This manuscript evaluates the assignments by applying EFSAs criteria to the CAGs "Toxicity to the nervous system" and "Toxicity to the thyroid hormone system (gland or hormones)". Assignment to the CAG "Toxicity to the nervous system" based, for example, on neurochemical effects like choline esterase inhibition is well supported, whereas assignment to the CAG "Toxicity to the thyroid hormone system (gland or hormones)" has been based in the examined case studies on non-reproducible effects seen in single studies or on observations that are not adverse. Therefore, a more detailed effects evaluation is required to assign a pesticide to a CAG for a target organ where many confounders regarding effects are present. Relative potency factors in cumulative risk assessment should be based on benchmark doses from studies in one species with identical study design and human relevance of effects on specific target organs should be analyzed to define minimal margins of exposure. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  8. Dosimetric and radiobiological consequences of computed tomography-guided adaptive strategies for intensity modulated radiation therapy of the prostate.

    PubMed

    Battista, Jerry J; Johnson, Carol; Turnbull, David; Kempe, Jeff; Bzdusek, Karl; Van Dyk, Jacob; Bauman, Glenn

    2013-12-01

    To examine a range of scenarios for image-guided adaptive radiation therapy of prostate cancer, including different schedules for megavoltage CT imaging, patient repositioning, and dose replanning. We simulated multifraction dose distributions with deformable registration using 35 sets of megavoltage CT scans of 13 patients. We computed cumulative dose-volume histograms, from which tumor control probabilities and normal tissue complication probabilities (NTCPs) for rectum were calculated. Five-field intensity modulated radiation therapy (IMRT) with 18-MV x-rays was planned to achieve an isocentric dose of 76 Gy to the clinical target volume (CTV). The differences between D95, tumor control probability, V70Gy, and NTCP for rectum, for accumulated versus planned dose distributions, were compared for different target volume sizes, margins, and adaptive strategies. The CTV D95 for IMRT treatment plans, averaged over 13 patients, was 75.2 Gy. Using the largest CTV margins (10/7 mm), the D95 values accumulated over 35 fractions were within 2% of the planned value, regardless of the adaptive strategy used. For tighter margins (5 mm), the average D95 values dropped to approximately 73.0 Gy even with frequent repositioning, and daily replanning was necessary to correct this deficit. When personalized margins were applied to an adaptive CTV derived from the first 6 treatment fractions using the STAPLE (Simultaneous Truth and Performance Level Estimation) algorithm, target coverage could be maintained using a single replan 1 week into therapy. For all approaches, normal tissue parameters (rectum V(70Gy) and NTCP) remained within acceptable limits. The frequency of adaptive interventions depends on the size of the CTV combined with target margins used during IMRT optimization. The application of adaptive target margins (<5 mm) to an adaptive CTV determined 1 week into therapy minimizes the need for subsequent dose replanning. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Patterns of Intraosseous Recurrence After Stereotactic Body Radiation Therapy for Coxal Bone Metastasis.

    PubMed

    Ito, Kei; Shimizuguchi, Takuya; Nihei, Keiji; Furuya, Tomohisa; Ogawa, Hiroaki; Tanaka, Hiroshi; Sasai, Keisuke; Karasawa, Katsuyuki

    2018-01-01

    To analyze the detailed pattern of intraosseous failure after stereotactic body radiation therapy (SBRT) for coxal bone metastasis. Patients treated with SBRT to coxal bone metastasis were identified by retrospective chart review. The SBRT doses were 30 Gy or 35 Gy in 5 fractions. A margin of 5 to 10 mm was added to the gross tumor volume to create the clinical target volume. We evaluated the presence or absence of intraosseous recurrence using magnetic resonance imaging. Intraosseous recurrences were assessed as "in-field" or "marginal/out-of-field." In addition, we measured the distance between the center of the recurrent tumor and the nearest edge of the initial bone metastasis in cases of marginal/out-of-field recurrence. Seventeen patients treated for 17 coxal bone metastases were included. Median age was 64 years (range, 48-79 years). Coxal lesions involved the ilium in 14 cases, pubis in 3, and ischium in 4 (3 lesions crossed over multiple regions). Patients most commonly had renal cell carcinoma (29.4%), followed by lung, hepatic cell, and colorectal cancers (23.5%, 11.8%, and 11.8%, respectively). Median follow-up after SBRT was 13 months (range, 2-44 months). Among all 17 cases, 7 cases developed 8 intraosseous recurrences, including in-field recurrence in 1 case and marginal/out-of-field recurrences in 7 cases. Median time to intraosseous recurrence was 10 months (range, 2-35 months). Among 7 cases with marginal/out-of-field recurrence, mean distance to the center of the recurrent tumor from the nearest edge of the initial bone metastasis was 34 mm (range, 15-55 mm). Most recurrences were observed out-of-field in the same coxal bone. These results suggest that defining the optimal clinical target volume in SBRT for coxal bone metastasis to obtain sufficient local tumor control is difficult. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Multiple two-dimensional versus three-dimensional PTV definition in treatment planning for conformal radiotherapy.

    PubMed

    Stroom, J C; Korevaar, G A; Koper, P C; Visser, A G; Heijmen, B J

    1998-06-01

    To demonstrate the need for a fully three-dimensional (3D) computerized expansion of the gross tumour volume (GTV) or clinical target volume (CTV), as delineated by the radiation oncologist on CT slices, to obtain the proper planning target volume (PTV) for treatment planning according to the ICRU-50 recommendations. For 10 prostate cancer patients two PTVs have been determined by expansion of the GTV with a 1.5 cm margin, i.e. a 3D PTV and a multiple 2D PTV. The former was obtained by automatically adding the margin while accounting in 3D for GTV contour differences in neighbouring slices. The latter was generated by automatically adding the 1.5 cm margin to the GTV in each CT slice separately; the resulting PTV is a computer simulation of the PTV that a radiation oncologist would obtain with (the still common) manual contouring in CT slices. For each patient the two PTVs were compared to assess the deviations of the multiple 2D PTV from the 3D PTV. For both PTVs conformal plans were designed using a three-field technique with fixed block margins. For each patient dose-volume histograms and tumour control probabilities (TCPs) of the (correct) 3D PTV were calculated, both for the plan designed for this PTV and for the treatment plan based on the (deviating) 2D PTV. Depending on the shape of the GTV, multiple 2D PTV generation could locally result in a 1 cm underestimation of the GTV-to-PTV margin. The deviations occurred predominantly in the cranio-caudal direction at locations where the GTV contour shape varies significantly from slice to slice. This could lead to serious underdosage and to a TCP decrease of up to 15%. A full 3D GTV-to-PTV expansion should be applied in conformal radiotherapy to avoid underdosage.

  11. Combined Recipe for Clinical Target Volume and Planning Target Volume Margins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stroom, Joep, E-mail: joep.stroom@fundacaochampalimaud.pt; Gilhuijs, Kenneth; Vieira, Sandra

    2014-03-01

    Purpose: To develop a combined recipe for clinical target volume (CTV) and planning target volume (PTV) margins. Methods and Materials: A widely accepted PTV margin recipe is M{sub geo} = aΣ{sub geo} + bσ{sub geo}, with Σ{sub geo} and σ{sub geo} standard deviations (SDs) representing systematic and random geometric uncertainties, respectively. On the basis of histopathology data of breast and lung tumors, we suggest describing the distribution of microscopic islets around the gross tumor volume (GTV) by a half-Gaussian with SD Σ{sub micro}, yielding as possible CTV margin recipe: M{sub micro} = ƒ(N{sub i}) × Σ{sub micro}, with N{sub i}more » the average number of microscopic islets per patient. To determine ƒ(N{sub i}), a computer model was developed that simulated radiation therapy of a spherical GTV with isotropic distribution of microscopic disease in a large group of virtual patients. The minimal margin that yielded D{sub min} <95% in maximally 10% of patients was calculated for various Σ{sub micro} and N{sub i}. Because Σ{sub micro} is independent of Σ{sub geo}, we propose they should be added quadratically, yielding for a combined GTV-to-PTV margin recipe: M{sub GTV-PTV} = √([aΣ{sub geo}]{sup 2} + [ƒ(N{sub i})Σ{sub micro}]{sup 2}) + bσ{sub geo}. This was validated by the computer model through numerous simultaneous simulations of microscopic and geometric uncertainties. Results: The margin factor ƒ(N{sub i}) in a relevant range of Σ{sub micro} and N{sub i} can be given by: ƒ(N{sub i}) = 1.4 + 0.8log(N{sub i}). Filling in the other factors found in our simulations (a = 2.1 and b = 0.8) yields for the combined recipe: M{sub GTV-PTV} = √((2.1Σ{sub geo}){sup 2} + ([1.4 + 0.8log(N{sub i})] × Σ{sub micro}){sup 2}) + 0.8σ{sub geo}. The average margin difference between the simultaneous simulations and the above recipe was 0.2 ± 0.8 mm (1 SD). Calculating M{sub geo} and M{sub micro} separately and adding them linearly overestimated PTVs by on average 5 mm. Margin recipes based on tumor control probability (TCP) instead of D{sub min} criteria yielded similar results. Conclusions: A general recipe for GTV-to-PTV margins is proposed, which shows that CTV and PTV margins should be added in quadrature instead of linearly.« less

  12. Dosimetrically Triggered Adaptive Intensity Modulated Radiation Therapy for Cervical Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lim, Karen; Stewart, James; Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario

    2014-09-01

    Purpose: The widespread use of intensity modulated radiation therapy (IMRT) for cervical cancer has been limited by internal target and normal tissue motion. Such motion increases the risk of underdosing the target, especially as planning margins are reduced in an effort to reduce toxicity. This study explored 2 adaptive strategies to mitigate this risk and proposes a new, automated method that minimizes replanning workload. Methods and Materials: Thirty patients with cervical cancer participated in a prospective clinical study and underwent pretreatment and weekly magnetic resonance (MR) scans over a 5-week course of daily external beam radiation therapy. Target volumes andmore » organs at risk (OARs) were contoured on each of the scans. Deformable image registration was used to model the accumulated dose (the real dose delivered to the target and OARs) for 2 adaptive replanning scenarios that assumed a very small PTV margin of only 3 mm to account for setup and internal interfractional motion: (1) a preprogrammed, anatomy-driven midtreatment replan (A-IMRT); and (2) a dosimetry-triggered replan driven by target dose accumulation over time (D-IMRT). Results: Across all 30 patients, clinically relevant target dose thresholds failed for 8 patients (27%) if 3-mm margins were used without replanning. A-IMRT failed in only 3 patients and also yielded an additional small reduction in OAR doses at the cost of 30 replans. D-IMRT assured adequate target coverage in all patients, with only 23 replans in 16 patients. Conclusions: A novel, dosimetry-triggered adaptive IMRT strategy for patients with cervical cancer can minimize the risk of target underdosing in the setting of very small margins and substantial interfractional motion while minimizing programmatic workload and cost.« less

  13. DVH- and NTCP-based dosimetric comparison of different longitudinal margins for VMAT-IMRT of esophageal cancer.

    PubMed

    Münch, S; Oechsner, M; Combs, S E; Habermehl, D

    2017-08-15

    To cover the microscopic tumor spread in squamous cell carcinoma of the esophagus (SCC), longitudinal margins of 3-4 cm are used for radiotherapy (RT) protocols. However, smaller margins of 2-3 cm might be reasonable when advanced diagnostic imaging is integrated into target volume delineation. Purpose of this study was to compare the dose distribution and deposition to the organs at risk (OAR) for different longitudinal margins using a DVH- and NTCP-based approach. Ten patients with SCC of the middle or lower third were retrospectively selected. Three planning target volumes (PTV) with longitudinal margins of 4 cm, 3 cm and 2 cm and an axial margin of 1.5 cm to the gross target volume (GTV) were defined for each patient. For each PTV two treatment plans with total doses of 41.4 Gy (neoadjuvant treatment) and 50.4 Gy (definite treatment) were calculated. Dose to the lungs, heart, myelon and liver were then evaluated and compared between different PTVs. When using a longitudinal margin of 3 cm instead of 4 cm, all dose parameters (Dmin, Dmean, Dmedian and V5-V35), except Dmax could be significantly reduced for the lungs. Regarding the heart, a significant reduction was seen for Dmean and V5, but not for Dmin, Dmax, Dmedian and V10-V35. When comparing a longitudinal margin of 4 cm to a longitudinal margin of 2 cm, a significant difference was calculated for Dmin, Dmean, Dmedian and V5-V35 of the lungs and for Dmax, Dmean and V5-V35 of the heart. Nevertheless, no difference was seen for median heart dose. An additional dose reduction for V10 of the heart was achieved for definite treatment plans when using a longitudinal margin of 3 cm. The NTCP-based risk of pneumonitis was significantly reduced by a margin reduction to 2 cm for neoadjuvant and definite treatment plans. Reduction of longitudinal margins from 4 cm to 3 cm can significantly reduce the dose to lungs and Dmean of the heart. Despite clinical benefit and oncologic outcome remain unclear, reduction of the longitudinal margins might provide the opportunity to reduce side effects of chemoradiation (CRT) for SCC in upcoming studies.

  14. WE-AB-207B-03: A Computational Methodology for Determination of CTV-To-PTV Margins with Inter Fractional Shape Variations Based On a Statistical Point Distribution Model for Prostate Cancer Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shibayama, Y; Umezu, Y; Nakamura, Y

    2016-06-15

    Purpose: Our assumption was that interfractional shape variations of target volumes could not be negligible for determination of clinical target volume (CTV)-to-planning target volume (PTV) margins. The aim of this study was to investigate this assumption as a simulation study by developing a computational framework of CTV-to-PTV margins with taking the interfractional shape variations into account based on point distribution model (PDM) Methods: The systematic and random errors for interfractional shape variations and translations of target volumes were evaluated for four types of CTV regions (only a prostate, a prostate plus proximal 1-cm seminal vesicles, a prostate plus proximal 2-cmmore » seminal vesicles, and a prostate plus whole seminal vesicles). The CTV regions were delineated depending on prostate cancer risk groups on planning computed tomography (CT) and cone beam CT (CBCT) images of 73 fractions of 10 patients. The random and systematic errors for shape variations of CTV regions were derived from PDMs of CTV surfaces for all fractions of each patient. Systematic errors of shape variations of CTV regions were derived by comparing PDMs between planning CTV surfaces and average CTV surfaces. Finally, anisotropic CTV-to-PTV margins with shape variations in 6 directions (anterior, posterior, superior, inferior, right, and left) were computed by using a van Herk margin formula. Results: Differences between CTV-to-PTV margins with and without shape variations ranged from 0.7 to 1.7 mm in anterior direction, 1.0 to 2.8 mm in posterior direction, 0.8 to 2.8 mm in superior direction, 0.6 to 1.6 mm in inferior direction, 1.4 to 4.4 mm in right direction, and 1.3 to 5.2 mm in left direction. Conclusion: More than 1.0 mm additional margins were needed at least in 3 directions to guarantee CTV coverage due to shape variations. Therefore, shape variations should be taken into account for the determination of CTV-to-PTV margins.« less

  15. Australasian Gastrointestinal Trials Group (AGITG) Contouring Atlas and Planning Guidelines for Intensity-Modulated Radiotherapy in Anal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ng, Michael, E-mail: mng@radoncvic.com.au; Leong, Trevor; University of Melbourne

    2012-08-01

    Purpose: To develop a high-resolution target volume atlas with intensity-modulated radiotherapy (IMRT) planning guidelines for the conformal treatment of anal cancer. Methods and Materials: A draft contouring atlas and planning guidelines for anal cancer IMRT were prepared at the Australasian Gastrointestinal Trials Group (AGITG) annual meeting in September 2010. An expert panel of radiation oncologists contoured an anal cancer case to generate discussion on recommendations regarding target definition for gross disease, elective nodal volumes, and organs at risk (OARs). Clinical target volume (CTV) and planning target volume (PTV) margins, dose fractionation, and other IMRT-specific issues were also addressed. A steeringmore » committee produced the final consensus guidelines. Results: Detailed contouring and planning guidelines and a high-resolution atlas are provided. Gross tumor and elective target volumes are described and pictorially depicted. All elective regions should be routinely contoured for all disease stages, with the possible exception of the inguinal and high pelvic nodes for select, early-stage T1N0. A 20-mm CTV margin for the primary, 10- to 20-mm CTV margin for involved nodes and a 7-mm CTV margin for the elective pelvic nodal groups are recommended, while respecting anatomical boundaries. A 5- to 10-mm PTV margin is suggested. When using a simultaneous integrated boost technique, a dose of 54 Gy in 30 fractions to gross disease and 45 Gy to elective nodes with chemotherapy is appropriate. Guidelines are provided for OAR delineation. Conclusion: These consensus planning guidelines and high-resolution atlas complement the existing Radiation Therapy Oncology Group (RTOG) elective nodal ano-rectal atlas and provide additional anatomic, clinical, and technical instructions to guide radiation oncologists in the planning and delivery of IMRT for anal cancer.« less

  16. An Image-Guided Study of Setup Reproducibility of Postmastectomy Breast Cancer Patients Treated With Inverse-Planned Intensity Modulated Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feng, Christine H.; Gerry, Emily; Chmura, Steven J.

    2015-01-01

    Purpose: To calculate planning target volume (PTV) margins for chest wall and regional nodal targets using daily orthogonal kilovolt (kV) imaging and to study residual setup error after kV alignment using volumetric cone-beam computed tomography (CBCT). Methods and Materials: Twenty-one postmastectomy patients were treated with intensity modulated radiation therapy with 7-mm PTV margins. Population-based PTV margins were calculated from translational shifts after daily kV positioning and/or weekly CBCT data for each of 8 patients, whose surgical clips were used as surrogates for target volumes. Errors from kV and CBCT data were mathematically combined to generate PTV margins for 3 simulatedmore » alignment workflows: (1) skin marks alone; (2) weekly kV imaging; and (3) daily kV imaging. Results: The kV data from 613 treatment fractions indicated that a 7-mm uniform margin would account for 95% of daily shifts if patients were positioned using only skin marks. Total setup errors incorporating both kV and CBCT data were larger than those from kV alone, yielding PTV expansions of 7 mm anterior–posterior, 9 mm left–right, and 9 mm superior–inferior. Required PTV margins after weekly kV imaging were similar in magnitude as alignment to skin marks, but rotational adjustments of patients were required in 32% ± 17% of treatments. These rotations would have remained uncorrected without the use of daily kV imaging. Despite the use of daily kV imaging, CBCT data taken at the treatment position indicate that an anisotropic PTV margin of 6 mm anterior–posterior, 4 mm left–right, and 8 mm superior–inferior must be retained to account for residual errors. Conclusions: Cone-beam CT provides additional information on 3-dimensional reproducibility of treatment setup for chest wall targets. Three-dimensional data indicate that a uniform 7-mm PTV margin is insufficient in the absence of daily IGRT. Interfraction movement is greater than suggested by 2-dimensional imaging, thus a margin of at least 4 to 8 mm must be retained despite the use of daily IGRT.« less

  17. Multiscale nonlinear microscopy and widefield white light imaging enables rapid histological imaging of surgical specimen margins

    PubMed Central

    Giacomelli, Michael G.; Yoshitake, Tadayuki; Cahill, Lucas C.; Vardeh, Hilde; Quintana, Liza M.; Faulkner-Jones, Beverly E.; Brooker, Jeff; Connolly, James L.; Fujimoto, James G.

    2018-01-01

    The ability to histologically assess surgical specimens in real-time is a long-standing challenge in cancer surgery, including applications such as breast conserving therapy (BCT). Up to 40% of women treated with BCT for breast cancer require a repeat surgery due to postoperative histological findings of close or positive surgical margins using conventional formalin fixed paraffin embedded histology. Imaging technologies such as nonlinear microscopy (NLM), combined with exogenous fluorophores can rapidly provide virtual H&E imaging of surgical specimens without requiring microtome sectioning, facilitating intraoperative assessment of margin status. However, the large volume of typical surgical excisions combined with the need for rapid assessment, make comprehensive cellular resolution margin assessment during surgery challenging. To address this limitation, we developed a multiscale, real-time microscope with variable magnification NLM and real-time, co-registered position display using a widefield white light imaging system. Margin assessment can be performed rapidly under operator guidance to image specific regions of interest located using widefield imaging. Using simulated surgical margins dissected from human breast excisions, we demonstrate that multi-centimeter margins can be comprehensively imaged at cellular resolution, enabling intraoperative margin assessment. These methods are consistent with pathology assessment performed using frozen section analysis (FSA), however NLM enables faster and more comprehensive assessment of surgical specimens because imaging can be performed without freezing and cryo-sectioning. Therefore, NLM methods have the potential to be applied to a wide range of intra-operative applications. PMID:29761001

  18. Control of aperture closure initiation during reach-to-grasp movements under manipulations of visual feedback and trunk involvement in Parkinson's disease.

    PubMed

    Rand, Miya Kato; Lemay, Martin; Squire, Linda M; Shimansky, Yury P; Stelmach, George E

    2010-03-01

    The present project was aimed at investigating how two distinct and important difficulties (coordination difficulty and pronounced dependency on visual feedback) in Parkinson's disease (PD) affect each other for the coordination between hand transport toward an object and the initiation of finger closure during reach-to-grasp movement. Subjects with PD and age-matched healthy subjects made reach-to-grasp movements to a dowel under conditions in which the target object and/or the hand were either visible or not visible. The involvement of the trunk in task performance was manipulated by positioning the target object within or beyond the participant's outstretched arm to evaluate the effects of increasing the complexity of intersegmental coordination under different conditions related to the availability of visual feedback in subjects with PD. General kinematic characteristics of the reach-to-grasp movements of the subjects with PD were altered substantially by the removal of target object visibility. Compared with the controls, the subjects with PD considerably lengthened transport time, especially during the aperture closure period, and decreased peak velocity of wrist and trunk movement without target object visibility. Most of these differences were accentuated when the trunk was involved. In contrast, these kinematic parameters did not change depending on the visibility of the hand for both groups. The transport-aperture coordination was assessed in terms of the control law according to which the initiation of aperture closure during the reach occurred when the hand distance-to-target crossed a hand-target distance threshold for grasp initiation that is a function of peak aperture, hand velocity and acceleration, trunk velocity and acceleration, and trunk-target distance at the time of aperture closure initiation. When the hand or the target object was not visible, both groups increased the hand-target distance threshold for grasp initiation compared to its value under full visibility, implying an increase in the hand-target distance-related safety margin for grasping. The increase in the safety margin due to the absence of target object vision or the absence of hand vision was accentuated in the subjects with PD compared to that in the controls. The pronounced increase in the safety margin due to absence of target object vision for the subjects with PD was further accentuated when the trunk was involved compared to when it was not involved. The results imply that individuals with PD have significant limitations regarding neural computations required for efficient utilization of internal representations of target object location and hand motion as well as proprioceptive information about the hand to compensate for the lack of visual information during the performance of complex multisegment movements.

  19. A Systematic Review of Training Interventions Addressing Sexual Violence against Marginalized At-Risk Groups of Women

    ERIC Educational Resources Information Center

    Kouta, Christiana; Pithara, Christalla; Zobnina, Anna; Apostolidou, Zoe; Christodoulou, Josie; Papadakaki, Maria; Chliaoutakis, Joannes

    2015-01-01

    Women from marginalized groups working in occupations such as domestic work are at increased risk for sexual violence. Scarce evidence exists about training interventions targeting such groups. The article aims to identify community and workplace-based training interventions aiming to increase capacity among marginalized at-risk women to deal with…

  20. Radiobiological impact of reduced margins and treatment technique for prostate cancer in terms of tumor control probability (TCP) and normal tissue complication probability (NTCP).

    PubMed

    Jensen, Ingelise; Carl, Jesper; Lund, Bente; Larsen, Erik H; Nielsen, Jane

    2011-01-01

    Dose escalation in prostate radiotherapy is limited by normal tissue toxicities. The aim of this study was to assess the impact of margin size on tumor control and side effects for intensity-modulated radiation therapy (IMRT) and 3D conformal radiotherapy (3DCRT) treatment plans with increased dose. Eighteen patients with localized prostate cancer were enrolled. 3DCRT and IMRT plans were compared for a variety of margin sizes. A marker detectable on daily portal images was presupposed for narrow margins. Prescribed dose was 82 Gy within 41 fractions to the prostate clinical target volume (CTV). Tumor control probability (TCP) calculations based on the Poisson model including the linear quadratic approach were performed. Normal tissue complication probability (NTCP) was calculated for bladder, rectum and femoral heads according to the Lyman-Kutcher-Burman method. All plan types presented essentially identical TCP values and very low NTCP for bladder and femoral heads. Mean doses for these critical structures reached a minimum for IMRT with reduced margins. Two endpoints for rectal complications were analyzed. A marked decrease in NTCP for IMRT plans with narrow margins was seen for mild RTOG grade 2/3 as well as for proctitis/necrosis/stenosis/fistula, for which NTCP <7% was obtained. For equivalent TCP values, sparing of normal tissue was demonstrated with the narrow margin approach. The effect was more pronounced for IMRT than 3DCRT, with respect to NTCP for mild, as well as severe, rectal complications. Copyright © 2011 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  1. Selection of appropriate tumour data sets for Benchmark Dose Modelling (BMD) and derivation of a Margin of Exposure (MoE) for substances that are genotoxic and carcinogenic: considerations of biological relevance of tumour type, data quality and uncertainty assessment.

    PubMed

    Edler, Lutz; Hart, Andy; Greaves, Peter; Carthew, Philip; Coulet, Myriam; Boobis, Alan; Williams, Gary M; Smith, Benjamin

    2014-08-01

    This article addresses a number of concepts related to the selection and modelling of carcinogenicity data for the calculation of a Margin of Exposure. It follows up on the recommendations put forward by the International Life Sciences Institute - European branch in 2010 on the application of the Margin of Exposure (MoE) approach to substances in food that are genotoxic and carcinogenic. The aims are to provide practical guidance on the relevance of animal tumour data for human carcinogenic hazard assessment, appropriate selection of tumour data for Benchmark Dose Modelling, and approaches for dealing with the uncertainty associated with the selection of data for modelling and, consequently, the derived Point of Departure (PoD) used to calculate the MoE. Although the concepts outlined in this article are interrelated, the background expertise needed to address each topic varies. For instance, the expertise needed to make a judgement on biological relevance of a specific tumour type is clearly different to that needed to determine the statistical uncertainty around the data used for modelling a benchmark dose. As such, each topic is dealt with separately to allow those with specialised knowledge to target key areas of guidance and provide a more in-depth discussion on each subject for those new to the concept of the Margin of Exposure approach. Copyright © 2013 ILSI Europe. Published by Elsevier Ltd.. All rights reserved.

  2. Origin of Tumor Recurrence After Intensity Modulated Radiation Therapy for Oropharyngeal Squamous Cell Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raktoe, Sawan A.S.; Dehnad, Homan, E-mail: h.dehnad@umcutrecht.nl; Raaijmakers, Cornelis P.J.

    Purpose: To model locoregional recurrences of oropharyngeal squamous cell carcinomas (OSCC) treated with primary intensity modulated radiation therapy (IMRT) in order to find the origins from which recurrences grow and relate their location to original target volume borders. Methods and Materials: This was a retrospective analysis of OSCC treated with primary IMRT between January 2002 and December 2009. Locoregional recurrence volumes were delineated on diagnostic scans and coregistered rigidly with treatment planning computed tomography scans. Each recurrence was analyzed with two methods. First, overlapping volumes of a recurrence and original target were measured ('volumetric approach') and assessed as 'in-field', 'marginal',more » or 'out-field'. Then, the center of mass (COM) of a recurrence volume was assumed as the origin from where a recurrence expanded, the COM location was compared with original target volume borders and assessed as 'in-field', 'marginal', or 'out-field'. Results: One hundred thirty-one OSCC were assessed. For all patients alive at the end of follow-up, the mean follow-up time was 40 months (range, 12-83 months); 2 patients were lost to follow-up. The locoregional recurrence rate was 27%. Of all recurrences, 51% were local, 23% were regional, and 26% had both local and regional recurrences. Of all recurrences, 74% had imaging available for assessment. Regarding volumetric analysis of local recurrences, 15% were in-field gross tumor volume (GTV), and 65% were in-field clinical tumor volume (CTV). Using the COM approach, we found that 70% of local recurrences were in-field GTV and 90% were in-field CTV. Of the regional recurrences, 25% were volumetrically in-field GTV, and using the COM approach, we found 54% were in-field GTV. The COM of local out-field CTV recurrences were maximally 16 mm outside CTV borders, whereas for regional recurrences, this was 17 mm. Conclusions: The COM model is practical and specific for recurrence assessment. Most recurrences originated in the GTV. This suggests radioresistance in certain tumor parts.« less

  3. The quantitative assessment of epicardial fat distribution on human hearts: Implications for epicardial electrophysiology.

    PubMed

    Mattson, Alexander R; Soto, Mario J; Iaizzo, Paul A

    2018-07-01

    Epicardial electrophysiological procedures rely on dependable interfacing with the myocardial tissue. For example, epicardial pacing systems must generate sustainable chronic pacing capture, while epicardial ablations must effectively deliver energy to the target hyper-excitable myocytes. The human heart has a significant adipose layer which may impede epicardial procedures. The objective of this study was to quantitatively assess the relative location of epicardial adipose on the human heart, to define locations where epicardial therapies might be performed successfully. We studied perfusion-fixed human hearts (n = 105) in multiple isolated planes including: left ventricular margin, diaphragmatic surface, and anterior right ventricle. Relative adipose distribution was quantitatively assessed via planar images, using a custom-generated image analysis algorithm. In these specimens, 76.7 ± 13.8% of the left ventricular margin, 72.7 ± 11.3% of the diaphragmatic surface, and 92.1 ± 8.7% of the anterior right margin were covered with superficial epicardial adipose layers. Percent adipose coverage significantly increased with age (P < 0.001) and history of coronary artery disease (P < 0.05). No significant relationships were identified between relative percent adipose coverage and gender, body weight or height, BMI, history of hypertension, and/or history of congestive heart failure. Additionally, we describe two-dimensional probability distributions of epicardial adipose coverage for each of the three analysis planes. In this study, we detail the quantitative assessment and probabilistic mapping of the distribution of superficial epicardial adipose on the adult human heart. These findings have implications relative to performing epicardial procedures and/or designing procedures or tools to successfully perform such treatments. Clin. Anat. 31:661-666, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  4. TU-AB-BRB-01: Coverage Evaluation and Probabilistic Treatment Planning as a Margin Alternative

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siebers, J.

    The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. Themore » treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.« less

  5. MO-FG-CAMPUS-JeP3-01: A Statistical Model for Analyzing the Rotational Error of Single Iso-Center Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, J; Dept of Radiation Oncology, New York Weill Cornell Medical Ctr, New York, NY

    Purpose: To develop a generalized statistical model that incorporates the treatment uncertainty from the rotational error of single iso-center technique, and calculate the additional PTV (planning target volume) margin required to compensate for this error. Methods: The random vectors for setup and additional rotation errors in the three-dimensional (3D) patient coordinate system were assumed to follow the 3D independent normal distribution with zero mean, and standard deviations σx, σy, σz, for setup error and a uniform σR for rotational error. Both random vectors were summed, normalized and transformed to the spherical coordinates to derive the chi distribution with 3 degreesmore » of freedom for the radical distance ρ. PTV margin was determined using the critical value of this distribution for 0.05 significant level so that 95% of the time the treatment target would be covered by ρ. The additional PTV margin required to compensate for the rotational error was calculated as a function of σx, σy, σz and σR. Results: The effect of the rotational error is more pronounced for treatments that requires high accuracy/precision like stereotactic radiosurgery (SRS) or stereotactic body radiotherapy (SBRT). With a uniform 2mm PTV margin (or σx =σy=σz=0.7mm), a σR=0.32mm will decrease the PTV coverage from 95% to 90% of the time, or an additional 0.2mm PTV margin is needed to prevent this loss of coverage. If we choose 0.2 mm as the threshold, any σR>0.3mm will lead to an additional PTV margin that cannot be ignored, and the maximal σR that can be ignored is 0.0064 rad (or 0.37°) for iso-to-target distance=5cm, or 0.0032 rad (or 0.18°) for iso-to-target distance=10cm. Conclusions: The rotational error cannot be ignored for high-accuracy/-precision treatments like SRS/SBRT, particularly when the distance between the iso-center and target is large.« less

  6. Assessment of the stability of a multimachine power system by the transient energy margin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stanton, S.E.

    1982-01-01

    This reasearch develops a tool for the direct assessment of the transient stability of a multimachine electric power system that is subject to a large disturbance. The tool is the Transient Energy Margin. The transient of interest is the first swing (or inertial) transient. The Transient Energy Margin is computed by evaluating an energy function using the relevant unstable equilibrium point and the system states at the instant the disturbance is removed. In evaluating the function, a significant portion of the fault kinetic energy is identified as not contributing to system instability. The resulting energy value is a measure ofmore » the margin-of-safety for the disturbed system. A distinction is proposed between assessing system stability and assessing system security. The Transient Energy Margin is used first to assess the stability of the system. This profile ranks various distrubances to display the strengths and weaknesses of the system. A modified Transient Energy Margin is then proposed as an assessment of security; the transient energy margin profile is repeated to evaluate the system response in terms of the local minimum energy conditions approached by the critical trajectories. Both techniques are applied to a practical, 17 generator test system.« less

  7. A systematic review of training interventions addressing sexual violence against marginalized at-risk groups of women.

    PubMed

    Kouta, Christiana; Pithara, Christalla; Zobnina, Anna; Apostolidou, Zoe; Christodoulou, Josie; Papadakaki, Maria; Chliaoutakis, Joannes

    2015-12-01

    Women from marginalized groups working in occupations such as domestic work are at increased risk for sexual violence. Scarce evidence exists about training interventions targeting such groups. The article aims to identify community and workplace-based training interventions aiming to increase capacity among marginalized at-risk women to deal with sexual violence. A systematic review was applied. Inclusion criteria were English language published between 2003 and 2013; reporting on delivery and/or evaluation; focusing on any form of sexual violence; delivered to professionals, affected or at-risk women; targeting migrant, at-risk women or domestic workers. Data were extracted on the setting, content, evaluation process and target population. Four studies which focused on prevention or responding to sexual violence were included. One study provided sexual violence training to vulnerable female and one provided a HIV prevention intervention to marginalized women. Learning objectives included increasing knowledge around issues of sexual violence and/or gender and human rights, prevention and response strategies. Two studies aimed to train trainers. All studies conducted an outcome evaluation and two a process evaluation. It seems there is a gap on participatory empowerment training for marginalized women. Community train-the-trainer interventions are imperative to protect themselves and deal with the risk of sexual violence. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  8. Margins: a status report from the Annual Meeting of the American Society of Breast Surgeons.

    PubMed

    Harness, Jay K; Giuliano, Armando E; Pockaj, Barbara A; Downs-Kelly, Erinn

    2014-10-01

    Since the emergence of breast conserving surgery (BCS) as an alternative to mastectomy in the 1980's, there has been little consensus on what constitutes acceptable margins for cases of invasive breast cancer, how best to evaluate margins in the operating room, or an understanding of the challenging process of margin assessment by pathologists. The program committee for the 15th Annual Meeting of The American Society of Breast Surgeons organized a plenary session to discuss the latest thinking and guidelines for these important issues. The SSO/ASTRO Consensus Guideline on Margins for BCS was an important focus of discussion. The SSO/ASTRO consensus panelists concluded that "no ink on tumor" is an adequate surgical margin for BCS in patients with invasive breast cancers. Intraoperative strategies to decrease the incidence of positive margins include intraoperative localization techniques (wire-localization, ultrasound, radioactive seed) and intraoperative margin assessments with specimen radiography, imprint cytology, and frozen section. Studies also demonstrate the positive effect of shave margins with or without intraoperative margin assessment. The College of American Pathologists protocols for breast specimen margin evaluation consider multiple variables that can impact the proper assessment of margins. These variables include: tissue fixation time, specimen orientation, cold ischemia time, leaking ink, specimen pancaking and others that surgeons need to be aware of. Determining when "enough is enough" should not only be the application of guidelines and national standards, but also a multidisciplinary discussion between breast cancer specialists for what is right for the individual patient's unique circumstances.

  9. Burn Injury Alters Epidermal Cholinergic Mediators and Increases HMGB1 and Caspase 3 in Autologous Donor Skin and Burn Margin

    PubMed Central

    Holmes, Casey J.; Plichta, Jennifer K.; Gamelli, Richard L.; Radek, Katherine A.

    2016-01-01

    Burn wound healing complications, such as graft failure or infection, are a major source of morbidity and mortality in burn patients. The mechanisms by which local burn injury alters epidermal barrier function in autologous donor skin and surrounding burn margin are largely undefined. We hypothesized that defects in the epidermal cholinergic system may impair epidermal barrier function and innate immune responses. The objective was to identify alterations in the epidermal cholinergic pathway, and their downstream targets, associated with inflammation and cell death. We established that protein levels, but not gene expression, of the α7 nicotinic acetylcholine receptor (CHRNA7) were significantly reduced in both donor and burn margin skin. Furthermore, the gene and protein levels of an endogenous allosteric modulator of CHRNA7, secreted mammalian Ly-6/urokinase-type plasminogen activator receptor-related protein-1 (SLURP1) and acetylcholine were significantly elevated in donor and burn margin skin. As downstream proteins of inflammatory and cell death targets of nAChR activation, we found significant elevations in epidermal High Mobility Group Box Protein 1 (HMGB1) and caspase 3 in donor and burn margin skin. Lastly, we employed a novel in vitro keratinocyte burn model to establish that burn injury influences the gene expression of these cholinergic mediators and their downstream targets. These results indicate that defects in cholinergic mediators and inflammatory/apoptotic molecules in donor and burn margin skin may directly contribute to graft failure or infection in burn patients. PMID:27648692

  10. MO-FG-CAMPUS-TeP2-04: Optimizing for a Specified Target Coverage Probability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fredriksson, A

    2016-06-15

    Purpose: The purpose of this work is to develop a method for inverse planning of radiation therapy margins. When using this method the user specifies a desired target coverage probability and the system optimizes to meet the demand without any explicit specification of margins to handle setup uncertainty. Methods: The method determines which voxels to include in an optimization function promoting target coverage in order to achieve a specified target coverage probability. Voxels are selected in a way that retains the correlation between them: The target is displaced according to the setup errors and the voxels to include are selectedmore » as the union of the displaced target regions under the x% best scenarios according to some quality measure. The quality measure could depend on the dose to the considered structure alone or could depend on the dose to multiple structures in order to take into account correlation between structures. Results: A target coverage function was applied to the CTV of a prostate case with prescription 78 Gy and compared to conventional planning using a DVH function on the PTV. Planning was performed to achieve 90% probability of CTV coverage. The plan optimized using the coverage probability function had P(D98 > 77.95 Gy) = 0.97 for the CTV. The PTV plan using a constraint on minimum DVH 78 Gy at 90% had P(D98 > 77.95) = 0.44 for the CTV. To match the coverage probability optimization, the DVH volume parameter had to be increased to 97% which resulted in 0.5 Gy higher average dose to the rectum. Conclusion: Optimizing a target coverage probability is an easily used method to find a margin that achieves the desired coverage probability. It can lead to reduced OAR doses at the same coverage probability compared to planning with margins and DVH functions.« less

  11. Effective collaboration between marginal metallophilic macrophages and CD8+ dendritic cells in the generation of cytotoxic T cells

    PubMed Central

    Backer, Ronald; Schwandt, Timo; Greuter, Mascha; Oosting, Marije; Jüngerkes, Frank; Tüting, Thomas; Boon, Louis; O’Toole, Tom; Kraal, Georg; Limmer, Andreas; den Haan, Joke M. M.

    2009-01-01

    The spleen is the lymphoid organ that induces immune responses toward blood-borne pathogens. Specialized macrophages in the splenic marginal zone are strategically positioned to phagocytose pathogens and cell debris, but are not known to play a role in the activation of T-cell responses. Here we demonstrate that splenic marginal metallophilic macrophages (MMM) are essential for cross-presentation of blood-borne antigens by splenic dendritic cells (DCs). Our data demonstrate that antigens targeted to MMM as well as blood-borne adenoviruses are efficiently captured by MMM and exclusively transferred to splenic CD8+ DCs for cross-presentation and for the activation of cytotoxic T lymphocytes. Depletion of macrophages in the marginal zone prevents cytotoxic T-lymphocyte activation by CD8+ DCs after antibody targeting or adenovirus infection. Moreover, we show that tumor antigen targeting to MMM is very effective as antitumor immunotherapy. Our studies point to an important role for splenic MMM in the initial steps of CD8+ T-cell immunity by capturing and concentrating blood-borne antigens and the transfer to cross-presenting DCs which can be used to design vaccination strategies to induce antitumor cytotoxic T-cell immunity. PMID:20018690

  12. What Matters for Marginalized Girls and Boys in Bangladesh: A Capabilities Approach for Understanding Educational Well-Being and Empowerment

    ERIC Educational Resources Information Center

    Dejaeghere, Joan; Lee, Soo Kyoung

    2011-01-01

    Ensuring the education of marginalized children has become an important agenda in order to reach the goals of universal primary education and gender equality. Education policies and projects aiming to target marginalized children often do so on the basis of demographic variables, such as sex, ethnicity, poverty and geography. We argue that this…

  13. Non-inferiority tests for anti-infective drugs using control group quantiles.

    PubMed

    Fay, Michael P; Follmann, Dean A

    2016-12-01

    In testing for non-inferiority of anti-infective drugs, the primary endpoint is often the difference in the proportion of failures between the test and control group at a landmark time. The landmark time is chosen to approximately correspond to the qth historic quantile of the control group, and the non-inferiority margin is selected to be reasonable for the target level q. For designing these studies, a troubling issue is that the landmark time must be pre-specified, but there is no guarantee that the proportion of control failures at the landmark time will be close to the target level q. If the landmark time is far from the target control quantile, then the pre-specified non-inferiority margin may not longer be reasonable. Exact variable margin tests have been developed by Röhmel and Kieser to address this problem, but these tests can have poor power if the observed control failure rate at the landmark time is far from its historic value. We develop a new variable margin non-inferiority test where we continue sampling until a pre-specified proportion of failures, q, have occurred in the control group, where q is the target quantile level. The test does not require any assumptions on the failure time distributions, and hence, no knowledge of the true [Formula: see text] control quantile for the study is needed. Our new test is exact and has power comparable to (or greater than) its competitors when the true control quantile from the study equals (or differs moderately from) its historic value. Our nivm R package performs the test and gives confidence intervals on the difference in failure rates at the true target control quantile. The tests can be applied to time to cure or other numeric variables as well. A substantial proportion of new anti-infective drugs being developed use non-inferiority tests in their development, and typically, a pre-specified landmark time and its associated difference margin are set at the design stage to match a specific target control quantile. If through changing standard of care or selection of a different population the target quantile for the control group changes from its historic value, then the appropriateness of the pre-specified margin at the landmark time may be questionable. Our proposed test avoids this problem by sampling until a pre-specified proportion of the controls have failed. © The Author(s) 2016.

  14. Marginal predation: do encounter or confusion effects explain the targeting of prey group edges?

    PubMed

    Duffield, Callum; Ioannou, Christos C

    2017-01-01

    Marginal predation, also known as the edge effect, occurs when aggregations of prey are preferentially targeted on their periphery by predators and has long been established in many taxa. Two main processes have been used to explain this phenomenon, the confusion effect and the encounter rate between predators and prey group edges. However, it is unknown at what size a prey group needs to be before marginal predation is detectable and to what extent each mechanism drives the effect. We conducted 2 experiments using groups of virtual prey being preyed upon by 3-spined sticklebacks ( Gasterosteus aculeatus ) to address these questions. In Experiment 1, we show that group sizes do not need to be large for marginal predation to occur, with this being detectable in groups of 16 or more. In Experiment 2, we find that encounter rate is a more likely explanation for marginal predation than the confusion effect in this system. We find that while confusion does affect predatory behaviors (whether or not predators make an attack), it does not affect marginal predation. Our results suggest that marginal predation is a more common phenomenon than originally thought as it also applies to relatively small groups. Similarly, as marginal predation does not need the confusion effect to occur, it may occur in a wider range of predator-prey species pairings, for example those where the predators search for prey using nonvisual sensory modalities.

  15. Marginal and Internal Adaptation of Zirconia Crowns: A Comparative Study of Assessment Methods.

    PubMed

    Cunali, Rafael Schlögel; Saab, Rafaella Caramori; Correr, Gisele Maria; Cunha, Leonardo Fernandes da; Ornaghi, Bárbara Pick; Ritter, André V; Gonzaga, Carla Castiglia

    2017-01-01

    Marginal and internal adaptation is critical for the success of indirect restorations. New imaging systems make it possible to evaluate these parameters with precision and non-destructively. This study evaluated the marginal and internal adaptation of zirconia copings fabricated with two different systems using both silicone replica and microcomputed tomography (micro-CT) assessment methods. A metal master model, representing a preparation for an all-ceramic full crown, was digitally scanned and polycrystalline zirconia copings were fabricated with either Ceramill Zi (Amann-Girrbach) or inCoris Zi (Dentslpy-Sirona), n=10. For each coping, marginal and internal gaps were evaluated by silicone replica and micro-CT assessment methods. Four assessment points of each replica cross-section and micro-CT image were evaluated using imaging software: marginal gap (MG), axial wall (AW), axio-occlusal angle (AO) and mid-occlusal wall (MO). Data were statistically analyzed by factorial ANOVA and Tukey test (a=0.05). There was no statistically significant difference between the methods for MG and AW. For AO, there were significant differences between methods for Amann copings, while for Dentsply-Sirona copings similar values were observed. For MO, both methods presented statistically significant differences. A positive correlation was observed determined by the two assessment methods for MG values. In conclusion, the assessment method influenced the evaluation of marginal and internal adaptation of zirconia copings. Micro-CT showed lower marginal and internal gap values when compared to the silicone replica technique, although the difference was not always statistically significant. Marginal gap and axial wall assessment points showed the lower gap values, regardless of ceramic system and assessment method used.

  16. Intra-fraction motion of larynx radiotherapy

    NASA Astrophysics Data System (ADS)

    Durmus, Ismail Faruk; Tas, Bora

    2018-02-01

    In early stage laryngeal radiotherapy, movement is an important factor. Thyroid cartilage can move from swallowing, breathing, sound and reflexes. The effects of this motion on the target volume (PTV) during treatment were examined. In our study, the target volume movement during the treatment for this purpose was examined. Thus, setup margins are re-evaluated and patient-based PTV margins are determined. Intrafraction CBCT was scanned in 246 fractions for 14 patients. During the treatment, the amount of deviation which could be lateral, vertical and longitudinal axis was determined. ≤ ± 0.1cm deviation; 237 fractions in the lateral direction, 202 fractions in the longitudinal direction, 185 fractions in the vertical direction. The maximum deviation values were found in the longitudinal direction. Intrafraction guide in laryngeal radiotherapy; we are sure of the correctness of the treatment, the target volume is to adjust the margin and dose more precisely, we control the maximum deviation of the target volume for each fraction. Although the image quality of intrafraction-CBCT scans was lower than the image quality of planning CT, they showed sufficient contrast for this work.

  17. Fast online replanning for interfraction rotation correction in prostate radiotherapy.

    PubMed

    Kontaxis, Charis; Bol, Gijsbert H; Kerkmeijer, Linda G W; Lagendijk, Jan J W; Raaymakers, Bas W

    2017-10-01

    To enable fast online replanning for prostate radiotherapy with the inclusion of interfraction rotations and translations and investigate the possibility for margin reduction via this regime. Online daily replanning for a 35-fraction treatment for five prostate cases is simulated while accounting for anatomical transformations derived from fiducial marker data available in our clinic. Two online replanning strategies were simulated, compensating for: (a) rotation-only in combination with a couch shift and (b) both translation and rotation without a couch shift. They were compared against our current clinical protocol consisting of a single offline plan used over all fractions with daily couch repositioning (translations only). For every patient, the above methods were generated for several planning margins (0-8 mm with 2 mm increments) in order to assess the performance of online replanning in terms of target coverage and investigate the possible dosimetric benefit for the organs at risk. The daily DVHs for each treatment strategy were used for evaluation and the non tumor integral dose (NTID) for the different margins was calculated in order to quantify the overall reduction of the delivered energy to the patient. Our system is able to generate a daily automated prostate plan in less than 2 min. For every patient, the daily treatment plans produce similar dose distributions to the original approved plan (average CTV D99 relative difference: 0.2%). The inclusion of both shifts and rotations can be effectively compensated via replanning among all planning margins (average CTV D99 difference: 0.01 Gy between the two replanning regimes). Online replanning is able to maintain target coverage among all margins, while - as expected - the conventional treatment plan is increasingly affected by the interfraction rotations as the margins shrink (average CTV D99 decrease: 0.2 Gy at 8 mm to 2.9 Gy at 0 mm margin). The possible gain in total delivered energy to the patient was quantified by the decreased NTID ranging from 12.6% at 6 mm to 32.9% at 0 mm. We demonstrate that fast daily replanning can be utilized to account for daily rotations and translations based on the daily positioning protocol. A daily plan can be generated from scratch in less than 2 min making it suitable for online application. Given the large magnitude of prostate rotation around the LR axis, online correction for daily rotations can be beneficial even for the clinical 8 mm margin and could be utilized for treatments with small margin reduction mainly limited then by anatomical deformations and intrafraction motion. Our online replanning pipeline can be used in future treatments with online MR guidance that can lead to further safe reduction of the planning margins. © 2017 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  18. The simulations of indirect-drive targets for ignition on megajoule lasers.

    NASA Astrophysics Data System (ADS)

    Lykov, Vladimir; Andreev, Eugene; Ardasheva, Ludmila; Avramenko, Michael; Chernyakov, Valerian; Chizhkov, Maxim; Karlykhanov, Nikalai; Kozmanov, Michael; Lebedev, Serge; Rykovanov, George; Seleznev, Vladimir; Sokolov, Lev; Timakova, Margaret; Shestakov, Alexander; Shushlebin, Aleksander

    2013-10-01

    The calculations were performed with use of radiation hydrodynamic codes developed in RFNC-VNIITF. The analysis of published calculations of indirect-drive targets to obtain ignition on NIF and LMJ lasers has shown that these targets have very low margins for ignition: according to 1D-ERA code calculations it could not be ignited under decreasing of thermonuclear reaction rate less than in 2 times.The purpose of new calculations is search of indirect-drive targets with the raised margins for ignition. The calculations of compression and thermonuclear burning of targets are carried out for conditions of X-ray flux asymmetry obtained in simulations of Rugby hohlraum that were performed with 2D-SINARA code. The requirements to accuracy of manufacturing and irradiation symmetry of targets were studied with use of 2D-TIGR-OMEGA-3T code. The necessity of performed researches is caused by the construction of magajoule laser in Russia.

  19. TU-AB-BRB-00: New Methods to Ensure Target Coverage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2015-06-15

    The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. Themore » treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.« less

  20. The impact of use of an intraoperative margin assessment device on re-excision rates.

    PubMed

    Sebastian, Molly; Akbari, Stephanie; Anglin, Beth; Lin, Erin H; Police, Alice M

    2015-01-01

    Historically there has been a high rate of surgical interventions to obtain clear margins for breast cancer patients undergoing breast conserving local therapy. An intraoperative margin assessment tool (MarginProbe) has been approved for use in the US since 2013. This study is the first compilation of data from routine use of the device, to assess the impact of device utilization on re-excision rates. We present a retrospective, observational, review from groups of consecutive patients, before and after the implementation of intraoperative use of the device during lumpectomy procedures. Lesions were localized by standard methods. The intraoperative margin assessment device was used on all circumferential margins of the main specimen, but not on any additional shavings. A positive reading by the device led to an additional shaving of the corresponding cavity location. Specimens were also, when feasible, imaged intra-operatively by X-ray, and additional shavings were taken if needed based on clinical assessment. For each surgeon, historical re-excision rates were established based on a consecutive set of patients from a time period proximal to initiation of use of the device. From March 2013 to April 2014 the device was routinely used by 4 surgeons in 3 centers. In total, 165 cases lumpectomy cases were performed. Positive margins resulted in additional re-excision procedures in 9.7% (16/165) of the cases. The corresponding historical set from 2012 and 2013 consisted of 186 Lumpectomy cases, in which additional re-excision procedures were performed in 25.8% (48/186) of the cases. The reduction in the rate of re-excision procedures was significant 62% (P < 0.0001). Use of an intraoperative margin assessment device contributes to achieving clear margins and reducing re-excision procedures. As in some cases positive margins were found on shavings, future studies of interest may include an analysis of the effect of using the device on the shavings intra-operatively.

  1. Head and Neck Margin Reduction With Adaptive Radiation Therapy: Robustness of Treatment Plans Against Anatomy Changes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kranen, Simon van; Hamming-Vrieze, Olga; Wolf, Annelisa

    Purpose: We set out to investigate loss of target coverage from anatomy changes in head and neck cancer patients as a function of applied safety margins and to verify a cone beam computed tomography (CBCT)–based adaptive strategy with an average patient anatomy to overcome possible target underdosage. Methods and Materials: For 19 oropharyngeal cancer patients, volumetric modulated arc therapy treatment plans (2 arcs; simultaneous integrated boost, 70 and 54.25 Gy; 35 fractions) were automatically optimized with uniform clinical target volume (CTV)–to–planning target volume margins of 5, 3, and 0 mm. We applied b-spline CBCT–to–computed tomography (CT) deformable registration to allow recalculation ofmore » the dose on modified CT scans (planning CT deformed to daily CBCT following online positioning) and dose accumulation in the planning CT scan. Patients with deviations in primary or elective CTV coverage >2 Gy were identified as candidates for adaptive replanning. For these patients, a single adaptive intervention was simulated with an average anatomy from the first 10 fractions. Results: Margin reduction from 5 mm to 3 mm to 0 mm generally led to an organ-at-risk (OAR) mean dose (D{sub mean}) sparing of approximately 1 Gy/mm. CTV shrinkage was mainly seen in the elective volumes (up to 10%), likely related to weight loss. Despite online repositioning, substantial systematic errors were present (>3 mm) in lymph node CTV, the parotid glands, and the larynx. Nevertheless, the average increase in OAR dose was small: maximum of 1.2 Gy (parotid glands, D{sub mean}) for all applied margins. Loss of CTV coverage >2 Gy was found in 1, 3, and 7 of 73 CTVs, respectively. Adaptive intervention in 0-mm plans substantially improved coverage: in 5 of 7 CTVs (in 6 patients) to <2 Gy of initially planned. Conclusions: Volumetric modulated arc therapy head and neck cancer treatment plans with 5-mm margins are robust for anatomy changes and show a modest increase in OAR dose. Margin reduction improves OAR sparing with approximately 1 Gy/mm at the expense of target coverage in a subgroup of patients. Patients at risk of CTV underdosage >2 Gy in 0-mm plans may be identified early in treatment using dose accumulation. A single intervention with an average anatomy derived from CBCT effectively mitigates discrepancies.« less

  2. PTV margin determination in conformal SRT of intracranial lesions

    PubMed Central

    Parker, Brent C.; Shiu, Almon S.; Maor, Moshe H.; Lang, Frederick F.; Liu, H. Helen; White, R. Allen; Antolak, John A.

    2002-01-01

    The planning target volume (PTV) includes the clinical target volume (CTV) to be irradiated and a margin to account for uncertainties in the treatment process. Uncertainties in miniature multileaf collimator (mMLC) leaf positioning, CT scanner spatial localization, CT‐MRI image fusion spatial localization, and Gill‐Thomas‐Cosman (GTC) relocatable head frame repositioning were quantified for the purpose of determining a minimum PTV margin that still delivers a satisfactory CTV dose. The measured uncertainties were then incorporated into a simple Monte Carlo calculation for evaluation of various margin and fraction combinations. Satisfactory CTV dosimetric criteria were selected to be a minimum CTV dose of 95% of the PTV dose and at least 95% of the CTV receiving 100% of the PTV dose. The measured uncertainties were assumed to be Gaussian distributions. Systematic errors were added linearly and random errors were added in quadrature assuming no correlation to arrive at the total combined error. The Monte Carlo simulation written for this work examined the distribution of cumulative dose volume histograms for a large patient population using various margin and fraction combinations to determine the smallest margin required to meet the established criteria. The program examined 5 and 30 fraction treatments, since those are the only fractionation schemes currently used at our institution. The fractionation schemes were evaluated using no margin, a margin of just the systematic component of the total uncertainty, and a margin of the systematic component plus one standard deviation of the total uncertainty. It was concluded that (i) a margin of the systematic error plus one standard deviation of the total uncertainty is the smallest PTV margin necessary to achieve the established CTV dose criteria, and (ii) it is necessary to determine the uncertainties introduced by the specific equipment and procedures used at each institution since the uncertainties may vary among locations. PACS number(s): 87.53.Kn, 87.53.Ly PMID:12132939

  3. Stereotactic Radiosurgery of the Postoperative Resection Cavity for Brain Metastases: Prospective Evaluation of Target Margin on Tumor Control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, Clara Y.H.; Chang, Steven D.; Gibbs, Iris C.

    2012-10-01

    Purpose: Given the neurocognitive toxicity associated with whole-brain irradiation (WBRT), approaches to defer or avoid WBRT after surgical resection of brain metastases are desirable. Our initial experience with stereotactic radiosurgery (SRS) targeting the resection cavity showed promising results. We examined the outcomes of postoperative resection cavity SRS to determine the effect of adding a 2-mm margin around the resection cavity on local failure (LF) and toxicity. Patients and Methods: We retrospectively evaluated 120 cavities in 112 patients treated from 1998-2009. Factors associated with LF and distant brain failure (DF) were analyzed using competing risks analysis, with death as a competingmore » risk. The overall survival (OS) rate was calculated by the Kaplan-Meier product-limit method; variables associated with OS were evaluated using the Cox proportional hazards and log rank tests. Results: The 12-month cumulative incidence rates of LF and DF, with death as a competing risk, were 9.5% and 54%, respectively. On univariate analysis, expansion of the cavity with a 2-mm margin was associated with decreased LF; the 12-month cumulative incidence rates of LF with and without margin were 3% and 16%, respectively (P=.042). The 12-month toxicity rates with and without margin were 3% and 8%, respectively (P=.27). On multivariate analysis, melanoma histology (P=.038) and number of brain metastases (P=.0097) were associated with higher DF. The median OS time was 17 months (range, 2-114 months), with a 12-month OS rate of 62%. Overall, WBRT was avoided in 72% of the patients. Conclusion: Adjuvant SRS targeting the resection cavity of brain metastases results in excellent local control and allows WBRT to be avoided in a majority of patients. A 2-mm margin around the resection cavity improved local control without increasing toxicity compared with our prior technique with no margin.« less

  4. The effects of particle size, shape, density and flow characteristics on particle margination to vascular walls in cardiovascular diseases.

    PubMed

    Ta, Hang T; Truong, Nghia P; Whittaker, Andrew K; Davis, Thomas P; Peter, Karlheinz

    2018-01-01

    Vascular-targeted drug delivery is a promising approach for the treatment of atherosclerosis, due to the vast involvement of endothelium in the initiation and growth of plaque, a characteristic of atherosclerosis. One of the major challenges in carrier design for targeting cardiovascular diseases (CVD) is that carriers must be able to navigate the circulation system and efficiently marginate to the endothelium in order to interact with the target receptors. Areas covered: This review draws on studies that have focused on the role of particle size, shape, and density (along with flow hemodynamics and hemorheology) on the localization of the particles to activated endothelial cell surfaces and vascular walls under different flow conditions, especially those relevant to atherosclerosis. Expert opinion: Generally, the size, shape, and density of a particle affect its adhesion to vascular walls synergistically, and these three factors should be considered simultaneously when designing an optimal carrier for targeting CVD. Available preliminary data should encourage more studies to be conducted to investigate the use of nano-constructs, characterized by a sub-micrometer size, a non-spherical shape, and a high material density to maximize vascular wall margination and minimize capillary entrapment, as carriers for targeting CVD.

  5. A review and assessment of non-governmental organization-based STD/AIDS education and prevention projects for marginalized groups.

    PubMed

    Crane, S F; Carswell, J W

    1992-06-01

    A review of projects run by non-governmental organizations (NGOs) in primarily developing countries, which have aimed to provide STD/AIDS education and prevention skills to various marginalized groups, reveals that past quantitative and formative research has failed to identify key programmatic factors which lead to more successful project implementation and sustainability. In observations, interviews with field staff, visits to program sites and information drawn from the literature, a variety of methods to reach a wide range of groups such as men who have sex with men, prostitutes, clients of prostitutes, prisoners, street children, migrant workers and refugees are explored. Factors found to facilitate project success include the following: at least one full-time committed staff member; respectful treatment and appropriate motivation of the target group; suitable and sufficient equipment and supplies (particularly condoms); planning ahead for the participation of HIV-positive individuals and ways to meet their needs; focusing on qualitative rather than quantitative evaluation; planning in advance beyond a 9 or 12 month 'model'. Despite some evidence that marginalized groups can be successfully motivated to practise safer sex through prevention education, long-term behaviour change still presents major challenges--even when specific conditions are met.

  6. Performance of an airborne imaging 92/183 GHz radiometer during the Bering Sea Marginal Ice Zone Experiment (MIZEX-WEST)

    NASA Technical Reports Server (NTRS)

    Gagliano, J. A.; Mcsheehy, J. J.; Cavalieri, D. J.

    1983-01-01

    An airborne imaging 92/183 GHz radiometer was recently flown onboard NASA's Convair 990 research aircraft during the February 1983 Bering Sea Marginal Ice Zone Experiment (MIZEX-WEST). The 92 GHz portion of the radiometer was used to gather ice signature data and to generate real-time millimeter wave images of the marginal ice zone. Dry atmospheric conditions in the Arctic resulted in good surface ice signature data for the 183 GHz double sideband (DSB) channel situated + or - 8.75 GHz away from the water vapor absorption line. The radiometer's beam scanner imaged the marginal ice zone over a + or - 45 degrees swath angle about the aircraft nadir position. The aircraft altitude was 30,000 feet (9.20 km) maximum and 3,000 feet (0.92 km) minimum during the various data runs. Calculations of the minimum detectable target (ice) size for the radiometer as a function of aircraft altitude were performed. In addition, the change in the atmospheric attenuation at 92 GHz under varying weather conditions was incorporated into the target size calculations. A radiometric image of surface ice at 92 GHz in the marginal ice zone is included.

  7. A hybrid strategy of offline adaptive planning and online image guidance for prostate cancer radiotherapy.

    PubMed

    Lei, Yu; Wu, Qiuwen

    2010-04-21

    Offline adaptive radiotherapy (ART) has been used to effectively correct and compensate for prostate motion and reduce the required margin. The efficacy depends on the characteristics of the patient setup error and interfraction motion through the whole treatment; specifically, systematic errors are corrected and random errors are compensated for through the margins. In online image-guided radiation therapy (IGRT) of prostate cancer, the translational setup error and inter-fractional prostate motion are corrected through pre-treatment imaging and couch correction at each fraction. However, the rotation and deformation of the target are not corrected and only accounted for with margins in treatment planning. The purpose of this study was to investigate whether the offline ART strategy is necessary for an online IGRT protocol and to evaluate the benefit of the hybrid strategy. First, to investigate the rationale of the hybrid strategy, 592 cone-beam-computed tomography (CBCT) images taken before and after each fraction for an online IGRT protocol from 16 patients were analyzed. Specifically, the characteristics of prostate rotation were analyzed. It was found that there exist systematic inter-fractional prostate rotations, and they are patient specific. These rotations, if not corrected, are persistent through the treatment fraction, and rotations detected in early fractions are representative of those in later fractions. These findings suggest that the offline adaptive replanning strategy is beneficial to the online IGRT protocol with further margin reductions. Second, to quantitatively evaluate the benefit of the hybrid strategy, 412 repeated helical CT scans from 25 patients during the course of treatment were included in the replanning study. Both low-risk patients (LRP, clinical target volume, CTV = prostate) and intermediate-risk patients (IRP, CTV = prostate + seminal vesicles) were included in the simulation. The contours of prostate and seminal vesicles were delineated on each CT. The benefit of margin reduction to compensate for both rotation and deformation in the hybrid strategy was evaluated geometrically. With the hybrid strategy, the planning margins can be reduced by 1.4 mm for LRP, and 2.0 mm for IRP, compared with the standard online IGRT only, to maintain the same 99% target volume coverage. The average relative reduction in planning target volume (PTV) based on the internal target volume (ITV) from PTV based on CTV is 19% for LRP, and 27% for IRP.

  8. SU-F-J-45: Sparing Normal Tissue with Ultra-High Dose Rate in Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feng, Y

    Purpose: To spare normal tissue by reducing the location uncertainty of a moving target, we proposed an ultra-high dose rate system and evaluated. Methods: High energy electrons generated with a linear accelerator were injected into a storage ring to be accumulated. The number of the electrons in the ring was determined based on the prescribed radiation dose. The dose was delivered within a millisecond, when an online imaging system found that the target was in the position that was consistent with that in a treatment plan. In such a short time period, the displacement of the target was negligible. Themore » margin added to the clinical target volume (CTV) could be reduced that was evaluated by comparing of volumes between CTV and ITV in 14 cases of lung stereotactic body radiation therapy (SBRT) treatments. A design of the ultra-high dose rate system was evaluated based clinical needs and the recent developments of low energy (a few MeV) electron storage ring. Results: This design of ultra-high dose rate system was feasible based on the techniques currently available. The reduction of a target volume was significant by reducing the margin that accounted the motion of the target. ∼50% volume reduction of the internal target volume (ITV) could be achieved in lung SBRT treatments. Conclusion: With this innovation of ultra-high dose rate system, the margin of target is able to be significantly reduced. It will reduce treatment time of gating and allow precisely specified gating window to improve the accuracy of dose delivering.« less

  9. Performance and role of the breast lesion excision system (BLES) in small clusters of suspicious microcalcifications.

    PubMed

    Scaperrotta, Gianfranco; Ferranti, Claudio; Capalbo, Emanuela; Paolini, Biagio; Marchesini, Monica; Suman, Laura; Folini, Cristina; Mariani, Luigi; Panizza, Pietro

    2016-01-01

    To assess the diagnostic performance of the BLES as a biopsy tool in patients with ≤ 1 cm clusters of BIRADS 4 microcalcifications, in order to possibly avoid surgical excision in selected patients. This is a retrospective study of 105 patients undergone to stereotactic breast biopsy with the BLES. It excises a single specimen containing the whole mammographic target, allowing better histological assessment due to preserved architecture. Our case series consists of 41 carcinomas (39%) and 64 benign lesions (61%). Cancer involved the specimen margins in 20/41 cases (48.8%) or was close to them (≤ 1 mm) in 14 cases (34.1%); margins were disease-free in only 7 DCIS (17.1%). At subsequent excision of 39/41 malignant cases, underestimation occurred for 5/32 DCIS (15.6%), residual disease was found in 15/39 cancers (38.5%) and no cancer in 19/39 cases (48.7%). For DCIS cases, no residual disease occurred for 66.7% G1-G2 cases and for 35.3% G3 cases (P=0.1556) as well as in 83.3%, 40.0% and 43.8% cases respectively for negative, close and positive BLES margins (P=0.2576). The BLES is a good option for removal of small clusters of breast microcalcifications, giving better histological interpretation, lower underestimation rates and possibly reducing the need of subsequent surgical excision in selected patients. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. Realistic respiratory motion margins for external beam partial breast irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conroy, Leigh; Quirk, Sarah; Department of Physics and Astronomy, University of Calgary, Calgary, Alberta T2N 1N4

    Purpose: Respiratory margins for partial breast irradiation (PBI) have been largely based on geometric observations, which may overestimate the margin required for dosimetric coverage. In this study, dosimetric population-based respiratory margins and margin formulas for external beam partial breast irradiation are determined. Methods: Volunteer respiratory data and anterior–posterior (AP) dose profiles from clinical treatment plans of 28 3D conformal radiotherapy (3DCRT) PBI patient plans were used to determine population-based respiratory margins. The peak-to-peak amplitudes (A) of realistic respiratory motion data from healthy volunteers were scaled from A = 1 to 10 mm to create respiratory motion probability density functions. Dosemore » profiles were convolved with the respiratory probability density functions to produce blurred dose profiles accounting for respiratory motion. The required margins were found by measuring the distance between the simulated treatment and original dose profiles at the 95% isodose level. Results: The symmetric dosimetric respiratory margins to cover 90%, 95%, and 100% of the simulated treatment population were 1.5, 2, and 4 mm, respectively. With patient set up at end exhale, the required margins were larger in the anterior direction than the posterior. For respiratory amplitudes less than 5 mm, the population-based margins can be expressed as a fraction of the extent of respiratory motion. The derived formulas in the anterior/posterior directions for 90%, 95%, and 100% simulated population coverage were 0.45A/0.25A, 0.50A/0.30A, and 0.70A/0.40A. The differences in formulas for different population coverage criteria demonstrate that respiratory trace shape and baseline drift characteristics affect individual respiratory margins even for the same average peak-to-peak amplitude. Conclusions: A methodology for determining population-based respiratory margins using real respiratory motion patterns and dose profiles in the AP direction was described. It was found that the currently used respiratory margin of 5 mm in partial breast irradiation may be overly conservative for many 3DCRT PBI patients. Amplitude alone was found to be insufficient to determine patient-specific margins: individual respiratory trace shape and baseline drift both contributed to the dosimetric target coverage. With respiratory coaching, individualized respiratory margins smaller than the full extent of motion could reduce planning target volumes while ensuring adequate coverage under respiratory motion.« less

  11. Three independent one-dimensional margins for single-fraction frameless stereotactic radiosurgery brain cases using CBCT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Qinghui; Chan, Maria F.; Burman, Chandra

    2013-12-15

    Purpose: Setting a proper margin is crucial for not only delivering the required radiation dose to a target volume, but also reducing the unnecessary radiation to the adjacent organs at risk. This study investigated the independent one-dimensional symmetric and asymmetric margins between the clinical target volume (CTV) and the planning target volume (PTV) for linac-based single-fraction frameless stereotactic radiosurgery (SRS).Methods: The authors assumed a Dirac delta function for the systematic error of a specific machine and a Gaussian function for the residual setup errors. Margin formulas were then derived in details to arrive at a suitable CTV-to-PTV margin for single-fractionmore » frameless SRS. Such a margin ensured that the CTV would receive the prescribed dose in 95% of the patients. To validate our margin formalism, the authors retrospectively analyzed nine patients who were previously treated with noncoplanar conformal beams. Cone-beam computed tomography (CBCT) was used in the patient setup. The isocenter shifts between the CBCT and linac were measured for a Varian Trilogy linear accelerator for three months. For each plan, the authors shifted the isocenter of the plan in each direction by ±3 mm simultaneously to simulate the worst setup scenario. Subsequently, the asymptotic behavior of the CTV V{sub 80%} for each patient was studied as the setup error approached the CTV-PTV margin.Results: The authors found that the proper margin for single-fraction frameless SRS cases with brain cancer was about 3 mm for the machine investigated in this study. The isocenter shifts between the CBCT and the linac remained almost constant over a period of three months for this specific machine. This confirmed our assumption that the machine systematic error distribution could be approximated as a delta function. This definition is especially relevant to a single-fraction treatment. The prescribed dose coverage for all the patients investigated was 96.1%± 5.5% with an extreme 3-mm setup error in all three directions simultaneously. It was found that the effect of the setup error on dose coverage was tumor location dependent. It mostly affected the tumors located in the posterior part of the brain, resulting in a minimum coverage of approximately 72%. This was entirely due to the unique geometry of the posterior head.Conclusions: Margin expansion formulas were derived for single-fraction frameless SRS such that the CTV would receive the prescribed dose in 95% of the patients treated for brain cancer. The margins defined in this study are machine-specific and account for nonzero mean systematic error. The margin for single-fraction SRS for a group of machines was also derived in this paper.« less

  12. SU-F-J-151: Evaluation of a Magnetic Resonance Image Gated Radiotherapy System Using a Motion Phantom and Radiochromic Film

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lamb, J; Ginn, J; O’Connell, D

    Purpose: Magnetic resonance image (MRI) guided radiotherapy enables gating directly on target position for soft-tissue targets in the lung and abdomen. We present a dosimetric evaluation of a commercially-available FDA-approved MRI-guided radiotherapy system’s gating performance using a MRI-compatible respiratory motion phantom and radiochromic film. Methods: The MRI-compatible phantom was capable of one-dimensional motion. The phantom consisted of a target rod containing high-contrast target inserts which moved inside a body structure containing background contrast material. The target rod was equipped with a radiochromic film insert. Treatment plans were generated for a 3 cm diameter spherical target, and delivered to the phantommore » at rest and in motion with and without gating. Both sinusoidal and actual tumor trajectories (two free-breathing trajectories and one repeated-breath hold) were used. Gamma comparison at 5%/3mm was used to measure fidelity to the static target dose distribution. Results: Without gating, gamma pass rates were 24–47% depending on motion trajectory. Using our clinical standard of repeated breath holds and a gating window of 3 mm with 10% of the target allowed outside the gating boundary, the gamma pass rate was 99.6%. Relaxing the gating window to 5 mm resulted in gamma pass rate of 98.6% with repeated breath holds. For all motion trajectories gated with 3 mm margin and 10% allowed out, gamma pass rates were between 64–100% (mean:87.5%). For a 5 mm margin and 10% allowed out, gamma pass rates were between 57–98% (mean: 82.49%), significantly lower than for 3 mm by paired t-test (p=0.01). Conclusion: We validated the performance of respiratory gating based on real-time cine MRI images with the only FDA-approved MRI-guided radiotherapy system. Our results suggest that repeated breath hold gating should be used when possible for best accuracy. A 3 mm gating margin is statistically significantly more accurate than a 5 mm gating margin.« less

  13. SU-E-T-364: Estimating the Minimum Number of Patients Required to Estimate the Required Planning Target Volume Margins for Prostate Glands

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bakhtiari, M; Schmitt, J; Sarfaraz, M

    2015-06-15

    Purpose: To establish a minimum number of patients required to obtain statistically accurate Planning Target Volume (PTV) margins for prostate Intensity Modulated Radiation Therapy (IMRT). Methods: A total of 320 prostate patients, consisting of a total number of 9311 daily setups, were analyzed. These patients had gone under IMRT treatments. Daily localization was done using the skin marks and the proper shifts were determined by the CBCT to match the prostate gland. The Van Herk formalism is used to obtain the margins using the systematic and random setup variations. The total patient population was divided into different grouping sizes varyingmore » from 1 group of 320 patients to 64 groups of 5 patients. Each grouping was used to determine the average PTV margin and its associated standard deviation. Results: Analyzing all 320 patients lead to an average Superior-Inferior margin of 1.15 cm. The grouping with 10 patients per group (32 groups) resulted to an average PTV margin between 0.6–1.7 cm with the mean value of 1.09 cm and a standard deviation (STD) of 0.30 cm. As the number of patients in groups increases the mean value of average margin between groups tends to converge to the true average PTV of 1.15 cm and STD decreases. For groups of 20, 64, and 160 patients a Superior-Inferior margin of 1.12, 1.14, and 1.16 cm with STD of 0.22, 0.11, and 0.01 cm were found, respectively. Similar tendency was observed for Left-Right and Anterior-Posterior margins. Conclusion: The estimation of the required margin for PTV strongly depends on the number of patients studied. According to this study at least ∼60 patients are needed to calculate a statistically acceptable PTV margin for a criterion of STD < 0.1 cm. Numbers greater than ∼60 patients do little to increase the accuracy of the PTV margin estimation.« less

  14. 12 CFR 502.15 - How does OTS determine my size component?

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... size component is: This amount—Base assessment amount Column C Plus—Marginal rate Column D Of assets... across in that same row, find your base assessment amount in Column C, your marginal rate in Column D... floor. Multiply this number by your Column D marginal rate. Add this number to your Column C base...

  15. SU-E-T-622: Planning Technique for Passively-Scattered Involved-Node Proton Therapy of Mediastinal Lymphoma with Consideration of Cardiac Motion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flampouri, S; Li, Z; Hoppe, B

    2015-06-15

    Purpose: To develop a treatment planning method for passively-scattered involved-node proton therapy of mediastinal lymphoma robust to breathing and cardiac motions. Methods: Beam-specific planning treatment volumes (bsPTV) are calculated for each proton field to incorporate pertinent uncertainties. Geometric margins are added laterally to each beam while margins for range uncertainty due to setup errors, breathing, and calibration curve uncertainties are added along each beam. The calculation of breathing motion and deformation effects on proton range includes all 4DCT phases. The anisotropic water equivalent margins are translated to distances on average 4DCT. Treatment plans are designed so each beam adequately coversmore » the corresponding bsPTV. For targets close to the heart, cardiac motion effects on dosemaps are estimated by using a library of anonymous ECG-gated cardiac CTs (cCT). The cCT, originally contrast-enhanced, are partially overridden to allow meaningful proton dose calculations. Targets similar to the treatment targets are drawn on one or more cCT sets matching the anatomy of the patient. Plans based on the average cCT are calculated on individual phases, then deformed to the average and accumulated. When clinically significant dose discrepancies occur between planned and accumulated doses, the patient plan is modified to reduce the cardiac motion effects. Results: We found that bsPTVs as planning targets create dose distributions similar to the conventional proton planning distributions, while they are a valuable tool for visualization of the uncertainties. For large targets with variability in motion and depth, integral dose was reduced because of the anisotropic margins. In most cases, heart motion has a clinically insignificant effect on target coverage. Conclusion: A treatment planning method was developed and used for proton therapy of mediastinal lymphoma. The technique incorporates bsPTVs compensating for all common sources of uncertainties and estimation of the effects of cardiac motion not commonly performed.« less

  16. Planning Target Margin Calculations for Prostate Radiotherapy Based on Intrafraction and Interfraction Motion Using Four Localization Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beltran, Chris; Herman, Michael G.; Davis, Brian J.

    2008-01-01

    Purpose: To determine planning target volume (PTV) margins for prostate radiotherapy based on the internal margin (IM) (intrafractional motion) and the setup margin (SM) (interfractional motion) for four daily localization methods: skin marks (tattoo), pelvic bony anatomy (bone), intraprostatic gold seeds using a 5-mm action threshold, and using no threshold. Methods and Materials: Forty prostate cancer patients were treated with external radiotherapy according to an online localization protocol using four intraprostatic gold seeds and electronic portal images (EPIs). Daily localization and treatment EPIs were obtained. These data allowed inter- and intrafractional analysis of prostate motion. The SM for the fourmore » daily localization methods and the IM were determined. Results: A total of 1532 fractions were analyzed. Tattoo localization requires a SM of 6.8 mm left-right (LR), 7.2 mm inferior-superior (IS), and 9.8 mm anterior-posterior (AP). Bone localization requires 3.1, 8.9, and 10.7 mm, respectively. The 5-mm threshold localization requires 4.0, 3.9, and 3.7 mm. No threshold localization requires 3.4, 3.2, and 3.2 mm. The intrafractional prostate motion requires an IM of 2.4 mm LR, 3.4 mm IS and AP. The PTV margin using the 5-mm threshold, including interobserver uncertainty, IM, and SM, is 4.8 mm LR, 5.4 mm IS, and 5.2 mm AP. Conclusions: Localization based on EPI with implanted gold seeds allows a large PTV margin reduction when compared with tattoo localization. Except for the LR direction, bony anatomy localization does not decrease the margins compared with tattoo localization. Intrafractional prostate motion is a limiting factor on margin reduction.« less

  17. Analysis of health sector gender equality and social inclusion strategy 2009 of Nepal.

    PubMed

    Mahara, G B; Dhital, S R

    2014-01-01

    The policy on gender equality and social inclusion (GESI) in health sector of Nepal is formulated in 2009 targeting toward poor, vulnerable, marginalized social and ethnic groups. Gender inequality and social discrimination are a social problem that affect on individual health finally. The main objective of this paper is to critically analysis and evaluates the Government's strategy on health sector gender equality and social inclusion in Nepal. We collected published and unpublished information assessing the public health, policy analysis and research needs from different sources. A different policy approaches for the analysis and evaluation of GESI strategies is applied in this paper. Universal education, community participation, individual, group and mass communication approaches, and social capital are the key aspects of effective implementation of policy at target levels.

  18. Pancreatic cancer cell detection by targeted lipid microbubbles and multiphoton imaging

    NASA Astrophysics Data System (ADS)

    Cromey, Benjamin; McDaniel, Ashley; Matsunaga, Terry; Vagner, Josef; Kieu, Khanh Quoc; Banerjee, Bhaskar

    2018-04-01

    Surgical resection of pancreatic cancer represents the only chance of cure and long-term survival in this common disease. Unfortunately, determination of a cancer-free margin at surgery is based on one or two tiny frozen section biopsies, which is far from ideal. Not surprisingly, cancer is usually left behind and is responsible for metastatic disease. We demonstrate a method of receptor-targeted imaging using peptide ligands, lipid microbubbles, and multiphoton microscopy that could lead to a fast and accurate way of examining the entire cut surface during surgery. Using a plectin-targeted microbubble, we performed a blinded in-vitro study to demonstrate avid binding of targeted microbubbles to pancreatic cancer cells but not noncancerous cell lines. Further work should lead to a much-needed point-of-care diagnostic test for determining clean margins in oncologic surgery.

  19. TU-AB-BRB-03: Coverage-Based Treatment Planning to Accommodate Organ Deformable Motions and Contouring Uncertainties for Prostate Treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, H.

    The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. Themore » treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.« less

  20. TU-AB-BRB-02: Stochastic Programming Methods for Handling Uncertainty and Motion in IMRT Planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Unkelbach, J.

    The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. Themore » treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.« less

  1. Titrating versus targeting home care services to frail elderly clients: an application of agency theory and cost-benefit analysis to home care policy.

    PubMed

    Weissert, William; Chernew, Michael; Hirth, Richard

    2003-02-01

    The article summarizes the shortcomings of current home care targeting policy, provides a conceptual framework for understanding the sources of its problems, and proposes an alternative resource allocation method. Methods required for different aspects of the study included synthesis of the published literature, regression analysis of risk predictors, and comparison of actual resource allocations with simulated budgets. Problems of imperfect agency ranging from unclear goals and inappropriate incentives to lack of information about the marginal effectiveness of home care could be mitigated with an improved budgeting method that combines client selection and resource allocation. No program can produce its best outcome performance when its goals are unclear and its technology is unstandardized. Titration of care would reallocate resources to maximize marginal benefit for marginal cost.

  2. Assessment of undiscovered petroleum resources of the Amerasia Basin Petroleum Province

    USGS Publications Warehouse

    Houseknecht, David W.; Bird, Kenneth J.; Garrity, Christopher P.

    2012-01-01

    The Amerasia Basin Petroleum Province encompasses the Canada Basin and the sediment prisms along the Alaska and Canada margins, outboard from basinward margins (hingelines) of the rift shoulders that formed during extensional opening of the Canada Basin. The province includes the Mackenzie delta and slope, the outer shelves and marine slopes along the Arctic margins of Alaska and Canada, and the deep Canada Basin. The province is divided into four assessment units (AUs): (1) The Canning-Mackenzie deformed margin AU is that part of the rifted margin where the Brooks Range orogenic belt has overridden the rift shoulder and is deforming the rifted-margin prism of sediment outboard of the hingeline. This is the only part of the Amerasia Basin Province that has been explored and—even though more than 3 billion barrels of oil equivalent (BBOE) of oil, gas, and condensate have been discovered—none has been commercially produced. (2) The Alaska passive margin AU is the rifted-margin prism of sediment lying beneath the Beaufort outer shelf and slope that has not been deformed by tectonism. (3) The Canada passive margin AU is the rifted-margin prism of sediment lying beneath the Arctic outer shelf and slope (also known as the polar margin) of Canada that has not been deformed by tectonism. (4) The Canada Basin AU includes the sediment wedge that lies beneath the deep Canada Basin, north of the marine slope developed along the Alaska and Canada margins. Mean estimates of risked, undiscovered, technically recoverable resources include more than 6 billion barrels of oil (BBO), more than 19 trillion cubic feet (TCF) of associated gas, and more than 16 TCF of nonassociated gas in the Canning-Mackenzie deformed margin AU; about 1 BBO, about 3 TCF of associated gas, and about 3 TCF of nonassociated gas in the Alaska passive margin AU; and more than 2 BBO, about 7 TCF of associated gas, and about 8 TCF of nonassociated gas in the Canada passive margin AU. Quantities of natural gas liquids also are assessed in each AU. The Canada Basin AU was not quantitatively assessed because it is judged to hold less than 10 percent probability of containing at least one accumulation of 50 million barrels of oil equivalent.

  3. Towards real-time detection of tumor margins using photothermal imaging of immune-targeted gold nanoparticles

    PubMed Central

    Jakobsohn, Kobi; Motiei, Menachem; Sinvani, Moshe; Popovtzer, Rachela

    2012-01-01

    Background One of the critical problems in cancer management is local recurrence of disease. Between 20% and 30% of patients who undergo tumor resection surgery require reoperation due to incomplete excision. Currently, there are no validated methods for intraoperative tumor margin detection. In the present work, we demonstrate the potential use of gold nanoparticles (GNPs) as a novel contrast agent for photothermal molecular imaging of cancer. Methods Phantoms containing different concentrations of GNPs were irradiated with continuous-wave laser and measured with a thermal imaging camera which detected the temperature field of the irradiated phantoms. Results The results clearly demonstrate the ability to distinguish between cancerous cells specifically targeted with GNPs and normal cells. This technique, which allows highly sensitive discrimination between adjacent low GNP concentrations, will allow tumor margin detection while the temperature increases by only a few degrees Celsius (for GNPs in relevant biological concentrations). Conclusion We expect this real-time intraoperative imaging technique to assist surgeons in determining clear tumor margins and to maximize the extent of tumor resection while sparing normal background tissue. PMID:22956871

  4. Indigenous women's voices: marginalization and health.

    PubMed

    Dodgson, Joan E; Struthers, Roxanne

    2005-10-01

    Marginalization may affect health care delivery. Ways in which indigenous women experienced marginalization were examined. Data from 57 indigenous women (18 to 65 years) were analyzed for themes. Three themes emerged: historical trauma as lived marginalization, biculturalism experienced as marginalization, and interacting within a complex health care system. Experienced marginalization reflected participants' unique perspective and were congruent with previous research. It is necessary for health care providers to assess the detrimental impact of marginalization on the health status of individuals and/or communities.

  5. Marginal capacity: the dilemmas faced in assessment and declaration.

    PubMed Central

    Ho, V

    1995-01-01

    Ontario is adopting informed-consent legislation that reflects increasing emphasis on patient autonomy and self-determination. Capacity assessment and declaration by physicians and other health care professionals are pivotal under the new legislation. While grossly capable or incapable patients provide few management difficulties, marginally capable patients provide a challenge for physicians who must assess capacity, and decisions concerning them emphasize the ethical dilemma involved in any declaration of incapacity. Our 1994 Logie Medical Ethics Essay first-prize winner, Vincent Ho, examines the issues that clinicians must consider when assessing marginally capable patients. Images p260-a PMID:7820810

  6. Investigations of Spatial and Temporal Variability of Ocean and Ice Conditions in and Near the Marginal Ice Zone. The “Marginal Ice Zone Observations and Processes Experiment” (MIZOPEX) Final Campaign Summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeMott, P. J.; Hill, T. C.J.

    Despite the significance of the marginal ice zones of the Arctic Ocean, basic parameters such as sea surface temperature (SST) and a range of sea-ice characteristics are still insufficiently understood in these areas, and especially so during the summer melt period. The field campaigns summarized here, identified collectively as the “Marginal Ice Zone Ocean and Ice Observations and Processes Experiment” (MIZOPEX), were funded by U.S. National Aeronautic and Space Administration (NASA) with the intent of helping to address these information gaps through a targeted, intensive observation field campaign that tested and exploited unique capabilities of multiple classes of unmanned aerialmore » systems (UASs). MIZOPEX was conceived and carried out in response to NASA’s request for research efforts that would address a key area of science while also helping to advance the application of UASs in a manner useful to NASA for assessing the relative merits of different UASs. To further exercise the potential of unmanned systems and to expand the science value of the effort, the field campaign added further challenges such as air deployment of miniaturized buoys and coordinating missions involving multiple aircraft. Specific research areas that MIZOPEX data were designed to address include relationships between ocean skin temperatures and subsurface temperatures and how these evolve over time in an Arctic environment during summer; variability in sea-ice conditions such as thickness, age, and albedo within the marginal ice zone (MIZ); interactions of SST, salinity, and ice conditions during the melt cycle; and validation of satellite-derived SST and ice concentration fields provided by satellite imagery and models.« less

  7. Marginal deformations of heterotic G 2 sigma models

    NASA Astrophysics Data System (ADS)

    Fiset, Marc-Antoine; Quigley, Callum; Svanes, Eirik Eik

    2018-02-01

    Recently, the infinitesimal moduli space of heterotic G 2 compactifications was described in supergravity and related to the cohomology of a target space differential. In this paper we identify the marginal deformations of the corresponding heterotic nonlinear sigma model with cohomology classes of a worldsheet BRST operator. This BRST operator is nilpotent if and only if the target space geometry satisfies the heterotic supersymmetry conditions. We relate this to the supergravity approach by showing that the corresponding cohomologies are indeed isomorphic. We work at tree-level in α' perturbation theory and study general geometries, in particular with non-vanishing torsion.

  8. Do marginal investments made by NHS healthcare commissioners in the UK produce the outcomes they hope to achieve? Observational study

    PubMed Central

    O'Cathain, Alicia; Sampson, Fiona; Strong, Mark; Pickin, Mark; Goyder, Elizabeth; Dixon, Simon

    2015-01-01

    Objective To investigate the effect of targeted marginal annual investments by local healthcare commissioners on the outcomes they expected to achieve with these investments. Design Controlled before and after study. Setting: 152 commissioning organisations (primary care trusts) in England. Methods National surveys of commissioning managers in 2009 and 2010 to identify: the largest marginal investments made in four key conditions/services (diabetes, coronary heart disease, chronic pulmonary airways disease and emergency and urgent care) in 2008/2009 and 2009/2010; the outcomes commissioners expected to achieve with these investments; and the processes commissioners used to develop these investments. Collation of routinely available data on outcomes commissioners expected from these investments over the period 2007/2008 to 2010/2011. Results 51% (77/152) of commissioners agreed to participate in the survey in 2009 and 60% (91/152) in 2010. Around half reported targeted marginal investments in each condition/service each year. Routine data on many of the outcomes they expected to achieve through these investments were not available. Also, commissioners expected some outcomes to be achieved beyond the time scale of our study. Therefore, only a limited number of outcomes of investments were tested. Outcomes included directly standardised emergency admission rates for the four conditions/services, and the percentage of patients with diabetes with glycated haemoglobin <7. There was no evidence that targeted marginal investments reduced emergency admission rates. There was evidence of an improvement in blood glucose management for diabetes for commissioners investing to improve diabetes care but this was compromised by a change in how the outcome was measured in different years. This investment was unlikely to be cost-effective. Conclusions Commissioners made marginal investments in specific health conditions and services with the aim of improving a wide range of outcomes. There was little evidence of impact on the limited number of outcomes measured. PMID:26546144

  9. A statistical model for analyzing the rotational error of single isocenter for multiple targets technique.

    PubMed

    Chang, Jenghwa

    2017-06-01

    To develop a statistical model that incorporates the treatment uncertainty from the rotational error of the single isocenter for multiple targets technique, and calculates the extra PTV (planning target volume) margin required to compensate for this error. The random vector for modeling the setup (S) error in the three-dimensional (3D) patient coordinate system was assumed to follow a 3D normal distribution with a zero mean, and standard deviations of σ x , σ y , σ z . It was further assumed that the rotation of clinical target volume (CTV) about the isocenter happens randomly and follows a three-dimensional (3D) independent normal distribution with a zero mean and a uniform standard deviation of σ δ . This rotation leads to a rotational random error (R), which also has a 3D independent normal distribution with a zero mean and a uniform standard deviation of σ R equal to the product of σδπ180 and dI⇔T, the distance between the isocenter and CTV. Both (S and R) random vectors were summed, normalized, and transformed to the spherical coordinates to derive the Chi distribution with three degrees of freedom for the radial coordinate of S+R. PTV margin was determined using the critical value of this distribution for a 0.05 significance level so that 95% of the time the treatment target would be covered by the prescription dose. The additional PTV margin required to compensate for the rotational error was calculated as a function of σ R and dI⇔T. The effect of the rotational error is more pronounced for treatments that require high accuracy/precision like stereotactic radiosurgery (SRS) or stereotactic body radiotherapy (SBRT). With a uniform 2-mm PTV margin (or σ x = σ y = σ z = 0.715 mm), a σ R = 0.328 mm will decrease the CTV coverage probability from 95.0% to 90.9%, or an additional 0.2-mm PTV margin is needed to prevent this loss of coverage. If we choose 0.2 mm as the threshold, any σ R > 0.328 mm will lead to an extra PTV margin that cannot be ignored, and the maximal σ δ that can be ignored is 0.45° (or 0.0079 rad ) for dI⇔T = 50 mm or 0.23° (or 0.004 rad ) for dI⇔T = 100 mm. The rotational error cannot be ignored for high-accuracy/-precision treatments like SRS/SBRT, particularly when the distance between the isocenter and target is large. © 2017 American Association of Physicists in Medicine.

  10. Pancreatic cancer cell detection by targeted lipid microbubbles and multiphoton imaging.

    PubMed

    Cromey, Benjamin; McDaniel, Ashley; Matsunaga, Terry; Vagner, Josef; Kieu, Khanh Quoc; Banerjee, Bhaskar

    2018-04-01

    Surgical resection of pancreatic cancer represents the only chance of cure and long-term survival in this common disease. Unfortunately, determination of a cancer-free margin at surgery is based on one or two tiny frozen section biopsies, which is far from ideal. Not surprisingly, cancer is usually left behind and is responsible for metastatic disease. We demonstrate a method of receptor-targeted imaging using peptide ligands, lipid microbubbles, and multiphoton microscopy that could lead to a fast and accurate way of examining the entire cut surface during surgery. Using a plectin-targeted microbubble, we performed a blinded in-vitro study to demonstrate avid binding of targeted microbubbles to pancreatic cancer cells but not noncancerous cell lines. Further work should lead to a much-needed point-of-care diagnostic test for determining clean margins in oncologic surgery. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  11. Invasive vulvar carcinoma and the question of the surgical margin.

    PubMed

    Palaia, Innocenza; Bellati, Filippo; Calcagno, Marco; Musella, Angela; Perniola, Giorgia; Panici, Pierluigi B

    2011-08-01

    To assess the discrepancy between width of surgical margin measured with the naked eye/ruler by a surgeon before removing an invasive vulvar carcinoma, and width of margin measured under microscope by pathologist after fixation of the resected lesion with formalin. Potential relationships between discrepancy and disease recurrence were also investigated. This prospective study was conducted with resected lesions from 86 women who underwent surgery for primary/recurrent invasive vulvar carcinoma. After the surgeon removed the lesions surrounded by 1-2-cm margins, the pathologist determined margin width at the 4 cardinal points of 86 lesions (for a total of 344 margin assessments), first macroscopically and then under the microscope. A safety margin of 0.8 cm on microscopic view was achieved in 83% of cases (112 of 135) when the macroscopic measurement was 1cm, in 91% of cases (58 of 64) when it was 1.5 cm, and 98% of cases (105 of 107) when it was 2 cm. There was a small discrepancy between the surgeon's intent and the microscopic margin measurement, mostly related to tissue shrinkage. A 1-cm surgical margin corresponded to a 0.8-cm margin in microscopic view (the "safe margin") in most cases. Copyright © 2011 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  12. Municipalities' Priority Problems and Prospect of Establishing Ordinance to Measures for Marginal Hamlets

    NASA Astrophysics Data System (ADS)

    Nakanishi, Mayumi; Hoshino, Satoshi; Hashimoto, Shizuka; Kuki, Yasuaki

    The problems of Marginal Hamlets are getting worse, in which more than half of the population is over 65 and community-based life is difficult. To contribute to effective policy making, we conducted a questionnaire survey to members of the National Liaison Council of ‘Suigen no Sato’ constituted to share information about problems and effective counter measures for marginal hamlets. Our study clarified that first, most of respondents had common problems such as lack of job-opportunities and animal damage on farm, and second, though most of respondents recognized the effectiveness of selecting target communities in policy implementations, it is difficult for municipal governments to establish such ordinance provided that councilors and those who were not living in areas of policy target wouldn't agree with it. Finally, we pointed out the roles of national and prefectural governments to help municipal governments effectively cope with such entangled situations.

  13. Sci—Fri AM: Mountain — 06: Optimizing planning target volume in lung radiotherapy using deformable registration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoang, P; Wierzbicki, M; Juravinski Cancer Centre, Medical Physics Department, Hamilton, Ontario

    A four dimensional computed tomography (4DCT) image is acquired for all radically treated, lung cancer patients to define the internal target volume (ITV), which encompasses tumour motion due to breathing and subclinical disease. Patient set-up error and anatomical motion that is not due to breathing is addressed through an additional 1 cm margin around the ITV to obtain the planning target volume (PTV). The objective of this retrospective study is to find the minimum PTV margin that provides an acceptable probability of delivering the prescribed dose to the ITV. Acquisition of a kV cone beam computed tomography (CBCT) image atmore » each fraction was used to shift the treatment couch to accurately align the spinal cord and carina. Our method utilized deformable image registration to automatically position the planning ITV on each CBCT. We evaluated the percentage of the ITV surface that fell within various PTVs for 79 fractions across 18 patients. Treatment success was defined as a situation where at least 99% of the ITV is covered by the PTV. Overall, this is to be achieved in at least 90% of the treatment fractions. The current approach with a 1cm PTV margin was successful ∼96% of the time. This analysis revealed that the current margin can be reduced to 0.8cm isotropic or 0.6×0.6×1 cm{sup 3} non-isotropic, which were successful 92 and 91 percent of the time respectively. Moreover, we have shown that these margins maintain accuracy, despite intrafractional variation, and maximize CBCT image guidance capabilities.« less

  14. Dose constraints for moderate hypofractionated radiotherapy for prostate cancer: The French genito-urinary group (GETUG) recommendations.

    PubMed

    Langrand-Escure, J; de Crevoisier, R; Llagostera, C; Créhange, G; Delaroche, G; Lafond, C; Bonin, C; Bideault, F; Sargos, P; Belhomme, S; Pasquier, D; Latorzeff, I; Supiot, S; Hennequin, C

    2018-04-01

    Considering recent phase III trials results, moderate hypofractionated radiotherapy can be considered as a standard treatment for low and intermediate risk prostate cancer management. This assessment call for a framework allowing homogeneous and reproducible practices in the different centers using this radiotherapy schedule. The French Genito-Urinary Group (GETUG) provides here recommendations for daily practice of moderate hypofractionated radiotherapy for prostate cancer, with indications, dose, fractionation, pre-treatment planning, volume of interest delineation (target volume and organs at risk) and margins, dose constraints and radiotherapy techniques. Copyright © 2018. Published by Elsevier SAS.

  15. Probabilistic objective functions for margin-less IMRT planning

    NASA Astrophysics Data System (ADS)

    Bohoslavsky, Román; Witte, Marnix G.; Janssen, Tomas M.; van Herk, Marcel

    2013-06-01

    We present a method to implement probabilistic treatment planning of intensity-modulated radiation therapy using custom software plugins in a commercial treatment planning system. Our method avoids the definition of safety-margins by directly including the effect of geometrical uncertainties during optimization when objective functions are evaluated. Because the shape of the resulting dose distribution implicitly defines the robustness of the plan, the optimizer has much more flexibility than with a margin-based approach. We expect that this added flexibility helps to automatically strike a better balance between target coverage and dose reduction for surrounding healthy tissue, especially for cases where the planning target volume overlaps organs at risk. Prostate cancer treatment planning was chosen to develop our method, including a novel technique to include rotational uncertainties. Based on population statistics, translations and rotations are simulated independently following a marker-based IGRT correction strategy. The effects of random and systematic errors are incorporated by first blurring and then shifting the dose distribution with respect to the clinical target volume. For simplicity and efficiency, dose-shift invariance and a rigid-body approximation are assumed. Three prostate cases were replanned using our probabilistic objective functions. To compare clinical and probabilistic plans, an evaluation tool was used that explicitly incorporates geometric uncertainties using Monte-Carlo methods. The new plans achieved similar or better dose distributions than the original clinical plans in terms of expected target coverage and rectum wall sparing. Plan optimization times were only about a factor of two higher than in the original clinical system. In conclusion, we have developed a practical planning tool that enables margin-less probability-based treatment planning with acceptable planning times, achieving the first system that is feasible for clinical implementation.

  16. Limitations of the planning organ at risk volume (PRV) concept.

    PubMed

    Stroom, Joep C; Heijmen, Ben J M

    2006-09-01

    Previously, we determined a planning target volume (PTV) margin recipe for geometrical errors in radiotherapy equal to M(T) = 2 Sigma + 0.7 sigma, with Sigma and sigma standard deviations describing systematic and random errors, respectively. In this paper, we investigated margins for organs at risk (OAR), yielding the so-called planning organ at risk volume (PRV). For critical organs with a maximum dose (D(max)) constraint, we calculated margins such that D(max) in the PRV is equal to the motion averaged D(max) in the (moving) clinical target volume (CTV). We studied margins for the spinal cord in 10 head-and-neck cases and 10 lung cases, each with two different clinical plans. For critical organs with a dose-volume constraint, we also investigated whether a margin recipe was feasible. For the 20 spinal cords considered, the average margin recipe found was: M(R) = 1.6 Sigma + 0.2 sigma with variations for systematic and random errors of 1.2 Sigma to 1.8 Sigma and -0.2 sigma to 0.6 sigma, respectively. The variations were due to differences in shape and position of the dose distributions with respect to the cords. The recipe also depended significantly on the volume definition of D(max). For critical organs with a dose-volume constraint, the PRV concept appears even less useful because a margin around, e.g., the rectum changes the volume in such a manner that dose-volume constraints stop making sense. The concept of PRV for planning of radiotherapy is of limited use. Therefore, alternative ways should be developed to include geometric uncertainties of OARs in radiotherapy planning.

  17. SU-F-BRD-09: Is It Sufficient to Use Only Low Density Tissue-Margin to Compensate Inter-Fractionation Setup Uncertainties in Lung Treatment?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nie, K; Yue, N; Chen, T

    2014-06-15

    Purpose: In lung radiation treatment, PTV is formed with a margin around GTV (or CTV/ITV). Although GTV is most likely of water equivalent density, the PTV margin may be formed with the surrounding low-density tissues, which may lead to unreal dosimetric plan. This study is to evaluate whether the concern of dose calculation inside the PTV with only low density margin could be justified in lung treatment. Methods: Three SBRT cases were analyzed. The PTV from the original plan (Plan-O) was created with a 5–10 mm margin outside the ITV to incorporate setup errors and all mobility from 10 respiratorymore » phases. Test plans were generated with the GTV shifted to the PTV edge to simulate the extreme situations with maximum setup uncertainties. Two representative positions as the very posterior-superior (Plan-PS) and anterior-inferior (Plan-AI) edge were considered. The virtual GTV was assigned a density of 1.0 g.cm−3 and surrounding lung, including the PTV margin, was defined as 0.25 g.cm−3. Also, additional plan with a 1mm tissue-margin instead of full lung-margin was created to evaluate whether a composite-margin (Plan-Comp) has a better approximation for dose calculation. All plans were generated on the average CT using Analytical Anisotropic Algorithm with heterogeneity correction on and all planning parameters/monitor unites remained unchanged. DVH analyses were performed for comparisons. Results: Despite the non-static dose distribution, the high-dose region synchronized with tumor positions. This might due to scatter conditions as greater doses were absorbed in the solid-tumor than in the surrounding low-density lungtissue. However, it still showed missing target coverage in general. Certain level of composite-margin might give better approximation for the dosecalculation. Conclusion: Our exploratory results suggest that with the lungmargin only, the planning dose of PTV might overestimate the coverage of the target during treatment. The significance of this overestimation might warrant further investigation.« less

  18. Radiotherapy beyond cancer: Target localization in real-time MRI and treatment planning for cardiac radiosurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ipsen, S.; Blanck, O.; Rades, D.

    2014-12-15

    Purpose: Atrial fibrillation (AFib) is the most common cardiac arrhythmia that affects millions of patients world-wide. AFib is usually treated with minimally invasive, time consuming catheter ablation techniques. While recently noninvasive radiosurgery to the pulmonary vein antrum (PVA) in the left atrium has been proposed for AFib treatment, precise target location during treatment is challenging due to complex respiratory and cardiac motion. A MRI linear accelerator (MRI-Linac) could solve the problems of motion tracking and compensation using real-time image guidance. In this study, the authors quantified target motion ranges on cardiac magnetic resonance imaging (MRI) and analyzed the dosimetric benefitsmore » of margin reduction assuming real-time motion compensation was applied. Methods: For the imaging study, six human subjects underwent real-time cardiac MRI under free breathing. The target motion was analyzed retrospectively using a template matching algorithm. The planning study was conducted on a CT of an AFib patient with a centrally located esophagus undergoing catheter ablation, representing an ideal case for cardiac radiosurgery. The target definition was similar to the ablation lesions at the PVA created during catheter treatment. Safety margins of 0 mm (perfect tracking) to 8 mm (untracked respiratory motion) were added to the target, defining the planning target volume (PTV). For each margin, a 30 Gy single fraction IMRT plan was generated. Additionally, the influence of 1 and 3 T magnetic fields on the treatment beam delivery was simulated using Monte Carlo calculations to determine the dosimetric impact of MRI guidance for two different Linac positions. Results: Real-time cardiac MRI showed mean respiratory target motion of 10.2 mm (superior–inferior), 2.4 mm (anterior–posterior), and 2 mm (left–right). The planning study showed that increasing safety margins to encompass untracked respiratory motion leads to overlapping structures even in the ideal scenario, compromising either normal tissue dose constraints or PTV coverage. The magnetic field caused a slight increase in the PTV dose with the in-line MRI-Linac configuration. Conclusions: The authors’ results indicate that real-time tracking and motion compensation are mandatory for cardiac radiosurgery and MRI-guidance is feasible, opening the possibility of treating cardiac arrhythmia patients completely noninvasively.« less

  19. 75 FR 13610 - Office of New Reactors; Interim Staff Guidance on Implementation of a Seismic Margin Analysis for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-22

    ... Staff Guidance on Implementation of a Seismic Margin Analysis for New Reactors Based on Probabilistic... Seismic Margin Analysis for New Reactors Based on Probabilistic Risk Assessment,'' (Agencywide Documents.../COL-ISG-020 ``Implementation of a Seismic Margin Analysis for New Reactors Based on Probabilistic Risk...

  20. Tumor margin detection using optical biopsy techniques

    NASA Astrophysics Data System (ADS)

    Zhou, Yan; Liu, Cheng-hui; Li, Jiyou; Li, Zhongwu; Zhou, Lixin; Chen, Ke; Pu, Yang; He, Yong; Zhu, Ke; Li, Qingbo; Alfano, Robert R.

    2014-03-01

    The aim of this study is to use the Resonance Raman (RR) and fluorescence spectroscopic technique for tumor margin detection with high accuracy based on native molecular fingerprints of breast and gastrointestinal (GI) tissues. This tumor margins detection method utilizes advantages of RR spectroscopic technique in situ and in real-time to diagnose tumor changes providing powerful tools for clinical guiding intraoperative margin assessments and postoperative treatments. The tumor margin detection procedures by RR spectroscopy were taken by scanning lesion from center or around tumor region in ex-vivo to find the changes in cancerous tissues with the rim of normal tissues using the native molecular fingerprints. The specimens used to analyze tumor margins include breast and GI carcinoma and normal tissues. The sharp margin of the tumor was found by the changes of RR spectral peaks within 2 mm distance. The result was verified using fluorescence spectra with 300 nm, 320 nm and 340 nm excitation, in a typical specimen of gastric cancerous tissue within a positive margin in comparison with normal gastric tissues. This study demonstrates the potential of RR and fluorescence spectroscopy as new approaches with labeling free to determine the intraoperative margin assessment.

  1. Methylation patterns in marginal zone lymphoma.

    PubMed

    Arribas, Alberto J; Bertoni, Francesco

    Promoter DNA methylation is a major regulator of gene expression and transcription. The identification of methylation changes is important for understanding disease pathogenesis, for identifying prognostic markers and can drive novel therapeutic approaches. In this review we summarize the current knowledge regarding DNA methylation in MALT lymphoma, splenic marginal zone lymphoma, nodal marginal zone lymphoma. Despite important differences in the study design for different publications and the existence of a sole large and genome-wide methylation study for splenic marginal zone lymphoma, it is clear that DNA methylation plays an important role in marginal zone lymphomas, in which it contributes to the inactivation of tumor suppressors but also to the expression of genes sustaining tumor cell survival and proliferation. Existing preclinical data provide the rationale to target the methylation machinery in these disorders. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Host-dependent variables: The missing link to personalized medicine.

    PubMed

    Demlova, Regina; Zdrazilova-Dubska, Lenka; Sterba, Jaroslav; Stanta, Giorgio; Valik, Dalibor

    2018-04-26

    Individualized medicine has the potential to tailor anticancer therapy with the best response and highest safety margin to provide better patient care. However, modern targeted therapies are still being tested through clinical trials comparing preselected patient cohorts and assessed upon behaviour of group averages. Clinically manifesting malignant disease requires identification of host- and tumour-dependent variables such as biological characteristics of the tumour and its microenvironment including immune response features, and overall capacity of the host to receive, tolerate and efficiently utilize treatment. Contemporary medical oncology including clinical trial design need to refocus from assessing group averages to individuality taking into consideration time dependent host-associated characteristics and reinventing outliers to be appreciated as naturally occurring variables collectively determining the ultimate outcome of malignant disease. Copyright © 2018. Published by Elsevier Ltd.

  3. Preliminary assessment of a Cretaceous-Paleogene Atlantic passive margin, Serrania del Interior and Central Ranges, Venezuela/Trinidad

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pindell, J.L.; Drake, C.L.; Pitman, W.C.

    1991-03-01

    For several decades, Cretaceous arc collision was assumed along northern Venezuela based on isotopic ages of metamorphic minerals. From subsidence histories in Venezuelan/Trinidadian basins, however, it is now clear that the Cretaceous metamorphic rocks were emplaced southeastward as allochthons above an autochthonous suite of rocks in the Cenozoic, and that the pre-Cenozoic autochthonous rocks represent a Mesozoic passive margin. The passive margin rocks have been metamorphosed separately during overthrusting by the allochthons in central Venezuela, but they are uplifted but not significantly metamorphosed in Eastern Venezuela and Trinidad. There, in the Serrania del Interior and Central Ranges of Venezuela/Trinidad, Mesozoic-Paleogenemore » passive margin sequences were uplifted in Neogene time, when the Caribbean Plate arrived from the west and transpressionally inverted the passive margin. Thus, this portion of South America's Atlantic margin subsided thermally without tectonism from Jurassic to Eocene time, and these sections comprise the only Mesozoic-Cenozoic truly passive Atlantic margin in the Western Hemisphere that is now exposed for direct study. Direct assessments of sedimentological, depositional and faunal features indicative of, and changes in, water depth for Cretaceous and Paleogene time may be made here relative to a thermally subsiding passive margin without the complications of tectonism. Work is underway, and preliminary assessments presented here suggest that sea level changes of Cretaceous-Paleogene time are not as pronounced as the frequent large and rapid sea level falls and rises that are promoted by some.« less

  4. Prevalence and covariates of food insecurity among residents of single-room occupancy housing in Chicago, IL, USA.

    PubMed

    Bowen, Elizabeth A; Bowen, Sarah K; Barman-Adhikari, Anamika

    2016-04-01

    Emerging evidence suggests that food insecurity is a significant public health concern among people who are homeless or marginally housed. The present study assessed prevalence of food insecurity and its covariates among a group of marginally housed individuals living in single-room occupancy (SRO) dwellings, a population for which there is little extant health or nutrition research. Cross-sectional survey incorporating the Household Food Insecurity Access Scale. Ten private SRO residences in the Uptown neighbourhood of Chicago, IL, USA, 2013. SRO residents over 18 years of age who were able to communicate verbally in English (n 153). Food insecurity was widespread among SRO residents, with 75 % of the sample considered food insecure and 52 % meeting criteria for severe food insecurity. Bivariate analyses indicated that female gender, eating most meals at a soup kitchen, having a mental health condition, problem drinking, having at least one chronic health condition, and diabetes were all significantly associated with food insecurity. In the multivariate ordered logistic regression model, eating most meals at a soup kitchen remained as the only significant correlate of food insecurity (OR=10·13). SRO residents and other marginally housed populations face unique food access challenges. Although targeted assistance in the form of food stamps and congregate meal programmes remains critical, efforts to prevent and address food insecurity among homeless and marginally housed individuals should include policy interventions that recognize poverty as the root cause of food insecurity and aim to increase overall income and improve housing conditions.

  5. Extensional fault geometry and its flexural isostatic response during the formation of the Iberia - Newfoundland conjugate rifted margins

    NASA Astrophysics Data System (ADS)

    Gómez-Romeu, Júlia; Kusznir, Nick; Manatschal, Gianreto; Roberts, Alan

    2017-04-01

    Despite magma-poor rifted margins having been extensively studied for the last 20 years, the evolution of extensional fault geometry and the flexural isostatic response to faulting remain still debated topics. We investigate how the flexural isostatic response to faulting controls the structural development of the distal part of rifted margins in the hyper-extended domain and the resulting sedimentary record. In particular we address an important question concerning the geometry and evolution of extensional faults within distal hyper-extended continental crust; are the seismically observed extensional fault blocks in this region allochthons from the upper plate or are they autochthons of the lower plate? In order to achieve our aim we focus on the west Iberian rifted continental margin along the TGS and LG12 seismic profiles. Our strategy is to use a kinematic forward model (RIFTER) to model the tectonic and stratigraphic development of the west Iberia margin along TGS-LG12 and quantitatively test and calibrate the model against breakup paleo-bathymetry, crustal basement thickness and well data. RIFTER incorporates the flexural isostatic response to extensional faulting, crustal thinning, lithosphere thermal loads, sedimentation and erosion. The model predicts the structural and stratigraphic consequences of recursive sequential faulting and sedimentation. The target data used to constrain model predictions consists of two components: (i) gravity anomaly inversion is used to determine Moho depth, crustal basement thickness and continental lithosphere thinning and (ii) reverse post-rift subsidence modelling consisting of flexural backstripping, decompaction and reverse post-rift thermal subsidence modelling is used to give paleo-bathymetry at breakup time. We show that successful modelling of the structural and stratigraphic development of the TGS-LG12 Iberian margin transect also requires the simultaneous modelling of the Newfoundland conjugate margin, which we constrain using target data from the SCREECH 2 seismic profile. We also show that for the successful modelling and quantitative validation of the lithosphere hyper-extension stage it is necessary to first have a good calibrated model of the necking phase. Not surprisingly the evolution of a rifted continental margin cannot be modelled without modelling and calibration of its conjugate margin.

  6. Dermatofibrosarcoma protuberans of the vulva: margins assessment and reconstructive options - a report of two cases.

    PubMed

    Bertolli, Eduardo; Bretchbuhl, Eduard Renè; Camarço, William Ricardo; Campagnari, Mariane; Molina, André Sapata; Baiocchi, Glauco; Macedo, Mariana Petaccia; Pinto, Clovis Antonio; Cunha, Isabela Werneck; Neto, João Pedreira

    2014-12-29

    Dermatofibrosarcoma Protuberans (DFSP) of the vulva is rare and oncologic surgery with free margins may lead to severe functional damage, requiring multidisciplinary approach regarding resection, margin assessment and reconstruction.Case Report: Two cases of DFSP in vulva were treated in a single institution. A 28-year-old patient with an incisional biopsy in the vulvar region revealing DFSP underwent a partial vulvectomy with clitoris preservation. Pathological studies revealed free margins and reconstructive surgery was performed. This patient is disease free in a 40 months follow up. The other, a 57-year-old patient was also referred after an incomplete resection of a DFSP in the vulvar region. A 1-cm margim resection followed by Complete Circumferential and Peripheral Deep Margin Assessment (CCPDMA) was performed. Although the upper lateral margin was positive, it was possible to perform another wide local excision with preservation of the clitoris and primary closure. DFSP of the vulva requires an accurate evaluation of margins, resections following oncological principles and reconstruction. Although being a very challenging lesion that usually implies difficult surgical management, if treated in a multidisciplinary environment, with surgical oncologists, experienced dermatopathologists and reconstructive surgeons can achieve good results. Even in difficult cases that presents with large lesions and compromising challenging areas, a complete oncologic resection can be performed minimizing functional damage for the patient.

  7. Role of specimen US for predicting resection margin status in breast conserving therapy.

    PubMed

    Moschetta, M; Telegrafo, M; Introna, T; Coi, L; Rella, L; Ranieri, V; Cirili, A; Stabile Ianora, A A; Angelelli, G

    2015-01-01

    To assess the diagnostic accuracy of specimen ultrasound (US) for predicting resection margin status in women undergoing breast conserving therapy for US-detected cancer, having the histological findings as the reference standard. A total of 132 consecutive patients (age range, 34-87 years; mean, 51 years) underwent breast-conserving surgery for US-detected invasive breast cancer. All surgical specimens underwent US examination. The presence of lesion within the specimen and its distance from the specimen margins were assessed considering a threshold distance between the lesion and specimen margins of 10 mm. US findings were then compared with the pathological ones and specimen US. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) for predicting histological margin status were evaluated, having the histological findings as the reference standard. The histological examination detected invasive ductal carcinoma in 96/132 (73%) cases, invasive lobular carcinoma in 32/132 (24%), mucinous carcinoma in 4/132 (3%). The pathological margin analysis revealed 96/132 (73%) negative margins and 36 (27%) close/positive margins. US examination detected all 132 breast lesions within the surgical specimens. 110 (83%) negative margins and 22 (17%) positive margins were found on US. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 44%, 94%, 80%, 73% and 82%, respectively, were found for specimen US. Specimen US represents a time and cost saving imaging tool for evaluating the presence of US detected-breast lesion within surgical specimen and for predicting the histological margin status.

  8. Do marginal investments made by NHS healthcare commissioners in the UK produce the outcomes they hope to achieve? Observational study.

    PubMed

    O'Cathain, Alicia; Sampson, Fiona; Strong, Mark; Pickin, Mark; Goyder, Elizabeth; Dixon, Simon

    2015-11-06

    To investigate the effect of targeted marginal annual investments by local healthcare commissioners on the outcomes they expected to achieve with these investments. Controlled before and after study. 152 commissioning organisations (primary care trusts) in England. National surveys of commissioning managers in 2009 and 2010 to identify: the largest marginal investments made in four key conditions/services (diabetes, coronary heart disease, chronic pulmonary airways disease and emergency and urgent care) in 2008/2009 and 2009/2010; the outcomes commissioners expected to achieve with these investments; and the processes commissioners used to develop these investments. Collation of routinely available data on outcomes commissioners expected from these investments over the period 2007/2008 to 2010/2011. 51% (77/152) of commissioners agreed to participate in the survey in 2009 and 60% (91/152) in 2010. Around half reported targeted marginal investments in each condition/service each year. Routine data on many of the outcomes they expected to achieve through these investments were not available. Also, commissioners expected some outcomes to be achieved beyond the time scale of our study. Therefore, only a limited number of outcomes of investments were tested. Outcomes included directly standardised emergency admission rates for the four conditions/services, and the percentage of patients with diabetes with glycated haemoglobin <7. There was no evidence that targeted marginal investments reduced emergency admission rates. There was evidence of an improvement in blood glucose management for diabetes for commissioners investing to improve diabetes care but this was compromised by a change in how the outcome was measured in different years. This investment was unlikely to be cost-effective. Commissioners made marginal investments in specific health conditions and services with the aim of improving a wide range of outcomes. There was little evidence of impact on the limited number of outcomes measured. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  9. Estimation of Inherent Safety Margins in Loaded Commercial Spent Nuclear Fuel Casks

    DOE PAGES

    Banerjee, Kaushik; Robb, Kevin R.; Radulescu, Georgeta; ...

    2016-06-15

    We completed a novel assessment to determine the unquantified and uncredited safety margins (i.e., the difference between the licensing basis and as-loaded calculations) available in as-loaded spent nuclear fuel (SNF) casks. This assessment was performed as part of a broader effort to assess issues and uncertainties related to the continued safety of casks during extended storage and transportability following extended storage periods. Detailed analyses crediting the actual as-loaded cask inventory were performed for each of the casks at three decommissioned pressurized water reactor (PWR) sites to determine their characteristics relative to regulatory safety criteria for criticality, thermal, and shielding performance.more » These detailed analyses were performed in an automated fashion by employing a comprehensive and integrated data and analysis tool—Used Nuclear Fuel-Storage, Transportation & Disposal Analysis Resource and Data System (UNF-ST&DARDS). Calculated uncredited criticality margins from 0.07 to almost 0.30 Δk eff were observed; calculated decay heat margins ranged from 4 to almost 22 kW (as of 2014); and significant uncredited transportation dose rate margins were also observed. The results demonstrate that, at least for the casks analyzed here, significant uncredited safety margins are available that could potentially be used to compensate for SNF assembly and canister structural performance related uncertainties associated with long-term storage and subsequent transportation. The results also suggest that these inherent margins associated with how casks are loaded could support future changes in cask licensing to directly or indirectly credit the margins. Work continues to quantify the uncredited safety margins in the SNF casks loaded at other nuclear reactor sites.« less

  10. Towards intraoperative assessment of tumor margins in breast surgery using optical coherence elastography (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Kennedy, Brendan F.; Wijesinghe, Philip; Allen, Wes M.; Chin, Lixin; Latham, Bruce; Saunders, Christobel M.; Sampson, David D.

    2016-03-01

    Surgical excision of tumor is a critical factor in the management of breast cancer. The most common surgical procedure is breast-conserving surgery. The surgeon's goal is to remove the tumor and a rim of healthy tissue surrounding the tumor: the surgical margin. A major issue in breast-conserving surgery is the absence of a reliable tool to guide the surgeon in intraoperatively assessing the margin. A number of techniques have been proposed; however, the re-excision rate remains high and has been reported to be in the range 30-60%. New tools are needed to address this issue. Optical coherence elastography (OCE) shows promise as a tool for intraoperative tumor margin assessment in breast-conserving surgery. Further advances towards clinical translation are limited by long scan times and small fields of view. In particular, scanning over sufficient areas to assess the entire margin in an intraoperative timeframe has not been shown to be feasible. Here, we present a protocol allowing ~75% of the surgical margins to be assessed within 30 minutes. To achieve this, we have incorporated a 65 mm-diameter (internal), wide-aperture annular piezoelectric transducer, allowing the entire surface of the excised tumor mass to be automatically imaged in an OCT mosaic comprised of 10 × 10 mm tiles. As OCT is effective in identifying adipose tissue, our protocol uses the wide-field OCT to selectively guide subsequent local OCE scanning to regions of solid tissue which often present low contrast in OCT images. We present promising examples from freshly excised human breast tissue.

  11. Glucokinase MODY and implications for treatment goals of common forms of diabetes.

    PubMed

    Ajjan, Ramzi A; Owen, Katharine R

    2014-12-01

    Treatment goals in diabetes concentrate on reducing the risk of vascular complications, largely through setting targets for glycated haemoglobin (HbA1c). These targets are based on epidemiological studies of complication development, but so far have not adequately addressed the adverse effects associated with lowering HbA1c towards the normal range. Glucokinase (GCK) mutations cause a monogenic form of hyperglycaemia (GCK-MODY) characterised by fasting hyperglycaemia with low postprandial glucose excursions and a marginally elevated HbA1c. Minimal levels of vascular complications (comparable with nondiabetic individuals) are observed in GCK-MODY, leading to the hypothesis that GCK-MODY may represent a useful paradigm for assessing treatment goals in all forms of diabetes. In this review, we discuss the evidence behind this concept, suggest ways of translating this hypothesis into clinical practice and address some of the caveats of such an approach.

  12. Intraoperative monitoring of marginal mandibular nerve during neck dissection.

    PubMed

    Tirelli, Giancarlo; Bergamini, Pier Riccardo; Scardoni, Alessandro; Gatto, Annalisa; Boscolo Nata, Francesca; Marcuzzo, Alberto Vito

    2018-05-01

    The purpose of this study was to assess the efficacy of intraoperative nerve integrity monitoring (NIM) to prevent marginal mandibular nerve injuries during neck dissection. This prospective study compared 36 patients undergoing NIM-assisted neck dissection from July 2014 to March 2015 to a cohort of 35 patients subjected to neck dissection over an identical period of time before the technique was introduced. We also assessed possible correlations between marginal mandibular nerve injuries and other factors, such as anthropometric measurements, presence of clinical neck metastases, type of neck dissection, and site of primary tumor. The incidence of marginal mandibular nerve paralyses was significantly lower among the group of patients undergoing NIM-assisted neck dissection (P = .021). There was no significant difference in the duration of the procedure, and the technique resulted in a limited increase of cost. No other factor seemed to influence the onset of marginal mandibular nerve palsy. In our opinion, NIM is a valuable aid for preventing marginal mandibular nerve injuries during neck dissection. © 2018 Wiley Periodicals, Inc.

  13. Toward Prostate Cancer Contouring Guidelines on Magnetic Resonance Imaging: Dominant Lesion Gross and Clinical Target Volume Coverage Via Accurate Histology Fusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gibson, Eli; Biomedical Engineering, University of Western Ontario, London, Ontario; Centre for Medical Image Computing, University College London, London

    Purpose: Defining prostate cancer (PCa) lesion clinical target volumes (CTVs) for multiparametric magnetic resonance imaging (mpMRI) could support focal boosting or treatment to improve outcomes or lower morbidity, necessitating appropriate CTV margins for mpMRI-defined gross tumor volumes (GTVs). This study aimed to identify CTV margins yielding 95% coverage of PCa tumors for prospective cases with high likelihood. Methods and Materials: Twenty-five men with biopsy-confirmed clinical stage T1 or T2 PCa underwent pre-prostatectomy mpMRI, yielding T2-weighted, dynamic contrast-enhanced, and apparent diffusion coefficient images. Digitized whole-mount histology was contoured and registered to mpMRI scans (error ≤2 mm). Four observers contoured lesion GTVs onmore » each mpMRI scan. CTVs were defined by isotropic and anisotropic expansion from these GTVs and from multiparametric (unioned) GTVs from 2 to 3 scans. Histologic coverage (proportions of tumor area on co-registered histology inside the CTV, measured for Gleason scores [GSs] ≥6 and ≥7) and prostate sparing (proportions of prostate volume outside the CTV) were measured. Nonparametric histologic-coverage prediction intervals defined minimal margins yielding 95% coverage for prospective cases with 78% to 92% likelihood. Results: On analysis of 72 true-positive tumor detections, 95% coverage margins were 9 to 11 mm (GS ≥ 6) and 8 to 10 mm (GS ≥ 7) for single-sequence GTVs and were 8 mm (GS ≥ 6) and 6 mm (GS ≥ 7) for 3-sequence GTVs, yielding CTVs that spared 47% to 81% of prostate tissue for the majority of tumors. Inclusion of T2-weighted contours increased sparing for multiparametric CTVs with 95% coverage margins for GS ≥6, and inclusion of dynamic contrast-enhanced contours increased sparing for GS ≥7. Anisotropic 95% coverage margins increased the sparing proportions to 71% to 86%. Conclusions: Multiparametric magnetic resonance imaging–defined GTVs expanded by appropriate margins may support focal boosting or treatment of PCa; however, these margins, accounting for interobserver and intertumoral variability, may preclude highly conformal CTVs. Multiparametric GTVs and anisotropic margins may reduce the required margins and improve prostate sparing.« less

  14. Spectrally Encoded Confocal Microscopy (SECM) for Diagnosing of Breast Cancer in Excision and Margin Specimens

    PubMed Central

    Brachtel, Elena F.; Johnson, Nicole B.; Huck, Amelia E.; Rice-Stitt, Travis L.; Vangel, Mark G.; Smith, Barbara L.; Tearney, Guillermo J.; Kang, Dongkyun

    2016-01-01

    A large percentage of breast cancer patients treated with breast conserving surgery need to undergo multiple surgeries due to positive margins found during post-operative margin assessment. Carcinomas could be removed completely during the initial surgery and additional surgery avoided if positive margins can be determined intra-operatively. Spectrally-encoded confocal microscopy (SECM) is a high-speed reflectance confocal microscopy technology that has a potential to rapidly image the entire surgical margin at sub-cellular resolution and accurately determine margin status intra-operatively. In this paper, in order to test feasibility of using SECM for intra-operative margin assessment, we have evaluated the diagnostic accuracy of SECM for detecting various types of breast cancers. Forty-six surgically-removed breast specimens were imaged with a SECM system. Side-by-side comparison between SECM and histologic images showed that SECM images can visualize key histomorphologic patterns of normal/benign and malignant breast tissues. Small (500 µm × 500 µm) spatially-registered SECM and histologic images (n=124 for each) were diagnosed independently by three pathologists with expertise in breast pathology. Diagnostic accuracy of SECM for determining malignant tissues was high, average sensitivity of 0.91, specificity of 0.93, positive predictive value of 0.95, and negative predictive value of 0.87. Intra-observer agreement and inter-observer agreement for SECM were also high, 0.87 and 0.84, respectively. Results from this study suggest that SECM may be developed into an intra-operative margin assessment tool for guiding breast cancer excisions. PMID:26779830

  15. Interfraction Prostate Movement in Bone Alignment After Rectal Enema for Radiotherapy

    PubMed Central

    Seo, Young Eun; Kim, Tae Hyo; Lee, Ki Soo; Cho, Won Yeol; Lee, Hyung-Sik; Hur, Won-Joo

    2014-01-01

    Purpose To assess the effect of a rectal enema on interfraction prostate movement in bone alignment (BA) for prostate radiotherapy (RT), we analyzed the spatial difference in prostates in a bone-matched setup. Materials and Methods We performed BA retrospectively with data from prostate cancer patients who underwent image-guided RT (IGRT). The prostate was identified with implanted fiducial markers. The setup for the IGRT was conducted with the matching of three fiducial markers on RT planning computed tomography images and those on two oblique kV x-ray images. Offline BA was performed at the same position. The coordinates of a virtual prostate in BA and a real prostate were obtained by use of the ExaxTrac/NovalisBody system, and the distance between them was calculated as the spatial difference. Interfraction prostate displacement was drawn from the comparison of the spatial differences. Results A total of 15 patients with localized prostate cancer treated with curative hypofractionated IGRT were enrolled. A total of 420 fractions were analyzed. The mean of the interfraction prostate displacements after BA was 3.12±2.00 mm (range, 0.20-10.53 mm). The directional difference was profound in the anterior-posterior and supero-inferior directions (2.14±1.73 mm and 1.97±1.44 mm, respectively) compared with the right-left direction (0.26±0.22 mm, p<0.05). The required margin around the clinical target volume was 4.97 mm with the formula of van Herk et al. Conclusions The interfraction prostate displacement was less frequent when a rectal enema was performed before the procedure. A rectal enema can be used to reduce interfraction prostate displacement and resulting clinical target volume-to-planning target volume margin. PMID:24466393

  16. Experiences with Recruitment of Marginalized Groups in a Danish Health Promotion Program: A Document Evaluation Study.

    PubMed

    Rasmussen, Marianne; Poulsen, Eva Kanstrup; Rytter, Anne Stoffersen; Kristiansen, Tine Mechlenborg; Bak, Carsten Kronborg

    2016-01-01

    Studies have found that marginalized groups living in deprived neighborhoods are less likely to participate in health programs compared to the majority of society. This study evaluates recruitment approaches conducted during a national government-funded project in 12 deprived neighborhoods across Denmark between 2010 and 2014. The aim of this study was to understand how recruitment approaches could promote participation in health programs within deprived neighborhoods to reach marginalized groups. Documents from all 12 of the included municipalities were collected to conduct a document evaluation. The collected documents consisted of 1,500 pages of written material with 12 project descriptions, three midterm and 10 final evaluations. The collected data were analyzed through a qualitative content analysis. The results are based on the fact that only 10 municipalities have developed evaluations related to recruitment, and only three evaluations provided a description of which marginalized groups were recruited. Challenges related to recruitment consist of difficulties involving the target group, including general distrust, language barriers and a lack of ability to cope with new situations and strangers. Additional geographical challenges emerged, especially in rural areas. Positive experiences with recruitment approaches were mainly related to relationship building and trust building, especially through face-to-face contact and the project employees' presence in the neighborhood. Additionally, adjusting some of the interventions and the recruitment strategy increased participation. This study found that relation and trust between the residents and the project employees is an important factor in the recruitment of marginalized groups in deprived neighborhoods as well as adjusting the health interventions or recruitment strategy to the target groups. In future research, it is necessary to examine which recruitment approaches are effective under which circumstances to increase participation among marginalized groups.

  17. Deformable Dose Reconstruction to Optimize the Planning and Delivery of Liver Cancer Radiotherapy

    NASA Astrophysics Data System (ADS)

    Velec, Michael

    The precise delivery of radiation to liver cancer patients results in improved control with higher tumor doses and minimized normal tissues doses. A margin of normal tissue around the tumor requires irradiation however to account for treatment delivery uncertainties. Daily image-guidance allows targeting of the liver, a surrogate for the tumor, to reduce geometric errors. However poor direct tumor visualization, anatomical deformation and breathing motion introduce uncertainties between the planned dose, calculated on a single pre-treatment computed tomography image, and the dose that is delivered. A novel deformable image registration algorithm based on tissue biomechanics was applied to previous liver cancer patients to track targets and surrounding organs during radiotherapy. Modeling these daily anatomic variations permitted dose accumulation, thereby improving calculations of the delivered doses. The accuracy of the algorithm to track dose was validated using imaging from a deformable, 3-dimensional dosimeter able to optically track absorbed dose. Reconstructing the delivered dose revealed that 70% of patients had substantial deviations from the initial planned dose. An alternative image-guidance technique using respiratory-correlated imaging was simulated, which reduced both the residual tumor targeting errors and the magnitude of the delivered dose deviations. A planning and delivery strategy for liver radiotherapy was then developed that minimizes the impact of breathing motion, and applied a margin to account for the impact of liver deformation during treatment. This margin is 38% smaller on average than the margin used clinically, and permitted an average dose-escalation to liver tumors of 9% for the same risk of toxicity. Simulating the delivered dose with deformable dose reconstruction demonstrated the plans with smaller margins were robust as 90% of patients' tumors received the intended dose. This strategy can be readily implemented with widely available technologies and thus can potentially improve local control for liver cancer patients receiving radiotherapy.

  18. Analysis of Prostate Patient Setup and Tracking Data: Potential Intervention Strategies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Su Zhong, E-mail: zsu@floridaproton.org; Zhang Lisha; Murphy, Martin

    Purpose: To evaluate the setup, interfraction, and intrafraction organ motion error distributions and simulate intrafraction intervention strategies for prostate radiotherapy. Methods and Materials: A total of 17 patients underwent treatment setup and were monitored using the Calypso system during radiotherapy. On average, the prostate tracking measurements were performed for 8 min/fraction for 28 fractions for each patient. For both patient couch shift data and intrafraction organ motion data, the systematic and random errors were obtained from the patient population. The planning target volume margins were calculated using the van Herk formula. Two intervention strategies were simulated using the tracking data:more » the deviation threshold and period. The related planning target volume margins, time costs, and prostate position 'fluctuation' were presented. Results: The required treatment margin for the left-right, superoinferior, and anteroposterior axes was 8.4, 10.8, and 14.7 mm for skin mark-only setup and 1.3, 2.3, and 2.8 mm using the on-line setup correction, respectively. Prostate motion significantly correlated among the superoinferior and anteroposterior directions. Of the 17 patients, 14 had prostate motion within 5 mm of the initial setup position for {>=}91.6% of the total tracking time. The treatment margin decreased to 1.1, 1.8, and 2.3 mm with a 3-mm threshold correction and to 0.5, 1.0, and 1.5 mm with an every-2-min correction in the left-right, superoinferior, and anteroposterior directions, respectively. The periodic corrections significantly increase the treatment time and increased the number of instances when the setup correction was made during transient excursions. Conclusions: The residual systematic and random error due to intrafraction prostate motion is small after on-line setup correction. Threshold-based and time-based intervention strategies both reduced the planning target volume margins. The time-based strategies increased the treatment time and the in-fraction position fluctuation.« less

  19. Optical assessment of tumor resection margins in the breast

    PubMed Central

    Brown, J. Quincy; Bydlon, Torre M.; Richards, Lisa M.; Yu, Bing; Kennedy, Stephanie A.; Geradts, Joseph; Wilke, Lee G.; Junker, Marlee; Gallagher, Jennifer; Barry, William; Ramanujam, Nimmi

    2011-01-01

    Breast conserving surgery, in which the breast tumor and surrounding normal tissue are removed, is the primary mode of treatment for invasive and in situ carcinomas of the breast, conditions that affect nearly 200,000 women annually. Of these nearly 200,000 patients who undergo this surgical procedure, between 20–70% of them may undergo additional surgeries to remove tumor that was left behind in the first surgery, due to the lack of intra-operative tools which can detect whether the boundaries of the excised specimens are free from residual cancer. Optical techniques have many attractive attributes which may make them useful tools for intra-operative assessment of breast tumor resection margins. In this manuscript, we discuss clinical design criteria for intra-operative breast tumor margin assessment, and review optical techniques appied to this problem. In addition, we report on the development and clinical testing of quantitative diffuse reflectance imaging (Q-DRI) as a potential solution to this clinical need. Q-DRI is a spectral imaging tool which has been applied to 56 resection margins in 48 patients at Duke University Medical Center. Clear sources of contrast between cancerous and cancer-free resection margins were identified with the device, and resulted in an overall accuracy of 75% in detecting positive margins. PMID:21544237

  20. Optimization of interneuron function by direct coupling of cell migration and axonal targeting.

    PubMed

    Lim, Lynette; Pakan, Janelle M P; Selten, Martijn M; Marques-Smith, André; Llorca, Alfredo; Bae, Sung Eun; Rochefort, Nathalie L; Marín, Oscar

    2018-06-18

    Neural circuit assembly relies on the precise synchronization of developmental processes, such as cell migration and axon targeting, but the cell-autonomous mechanisms coordinating these events remain largely unknown. Here we found that different classes of interneurons use distinct routes of migration to reach the embryonic cerebral cortex. Somatostatin-expressing interneurons that migrate through the marginal zone develop into Martinotti cells, one of the most distinctive classes of cortical interneurons. For these cells, migration through the marginal zone is linked to the development of their characteristic layer 1 axonal arborization. Altering the normal migratory route of Martinotti cells by conditional deletion of Mafb-a gene that is preferentially expressed by these cells-cell-autonomously disrupts axonal development and impairs the function of these cells in vivo. Our results suggest that migration and axon targeting programs are coupled to optimize the assembly of inhibitory circuits in the cerebral cortex.

  1. Marginally perceptible outcome feedback, motor learning and implicit processes.

    PubMed

    Masters, Rich S W; Maxwell, Jon P; Eves, Frank F

    2009-09-01

    Participants struck 500 golf balls to a concealed target. Outcome feedback was presented at the subjective or objective threshold of awareness of each participant or at a supraliminal threshold. Participants who received fully perceptible (supraliminal) feedback learned to strike the ball onto the target, as did participants who received feedback that was only marginally perceptible (subjective threshold). Participants who received feedback that was not perceptible (objective threshold) showed no learning. Upon transfer to a condition in which the target was unconcealed, performance increased in both the subjective and the objective threshold condition, but decreased in the supraliminal condition. In all three conditions, participants reported minimal declarative knowledge of their movements, suggesting that deliberate hypothesis testing about how best to move in order to perform the motor task successfully was disrupted by the impoverished disposition of the visual outcome feedback. It was concluded that sub-optimally perceptible visual feedback evokes implicit processes.

  2. Predictive teratology: teratogenic risk-hazard identification partnered in the discovery process.

    PubMed

    Augustine-Rauch, K A

    2008-11-01

    Unexpected teratogenicity is ranked as one of the most prevalent causes for toxicity-related attrition of drug candidates. Without proactive assessment, the liability tends to be identified relatively late in drug development, following significant investment in compound and engagement in pre clinical and clinical studies. When unexpected teratogenicity occurs in pre-clinical development, three principle questions arise: Can clinical trials that include women of child bearing populations be initiated? Will all compounds in this pharmacological class produce the same liability? Could this effect be related to the chemical structure resulting in undesirable off-target adverse effects? The first question is typically addressed at the time of the unexpected finding and involves considering the nature of the teratogenicity, whether or not maternal toxicity could have had a role in onset, human exposure margins and therapeutic indication. The latter two questions can be addressed proactively, earlier in the discovery process as drug target profiling and lead compound optimization is taking place. Such proactive approaches include thorough assessment of the literature for identification of potential liabilities and follow-up work that can be conducted on the level of target expression and functional characterization using molecular biology and developmental model systems. Developmental model systems can also be applied in the form of in vitro teratogenicity screens, and show potential for effective hazard identification or issue resolution on the level of characterizing teratogenic mechanism. This review discusses approaches that can be applied for proactive assessment of compounds for teratogenic liability.

  3. 76 FR 5518 - Antidumping Proceedings: Calculation of the Weighted Average Dumping Margin and Assessment Rate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-01

    ... DEPARTMENT OF COMMERCE International Trade Administration 19 CFR Part 351 [Docket No. 101130598-1052-02] RIN 0625-AA87 Antidumping Proceedings: Calculation of the Weighted Average Dumping Margin and Assessment Rate in Certain Antidumping Duty Proceedings AGENCY: Import Administration, International Trade...

  4. A comparative analysis of toluidine blue with frozen section in oral squamous cell carcinoma

    PubMed Central

    2012-01-01

    Background Surgical excision of the primary tumor with safe margins remains the mainstay of treatment for oral cavity squamous cell carcinoma (OSCC). The standard of care for assessment of intraoperative margins is frozen section histopathology. Unfortunately the facility is not available at most centers in limited resource countries. Toluidine blue, a metachromatic dye, has been well described in clinical identification of malignant and premalignant lesion in the oral cavity. Considering this we decided to explore intraoperative use of toluidine blue staining, in comparison with frozen sections, for the assessment of tumor-free margins. Methods After obtaining clearance from the in-house ethical review committee, a prospective study was conducted at Aga Khan University Hospital, Karachi, from August 15, 2009 to March 14, 2010. A sample of 56 consenting patients with biopsy-proven OSCC were included in the study, giving us 280 tumor margins. Margins were analyzed using toluidine blue staining and frozen section histopathology. A receiver operator curve (ROC) was then applied to compare assessment of margin status by toluidine blue and frozen section. Results Of the 280 examined margins 11 stained positive with toluidine blue, three were positive on frozen section biopsy, and three were positive on final histopathology. Toluidine blue staining had sensitivity and specificity of 100% and 97%, respectively. The diagnostic accuracy of toluidine blue was found to be 97.1% with a positive predictive value (PPV) of 27.2% and a negative predictive value (NPV) of 100%. Conclusions Toluidine blue can be used as an effective screening modality for the assessment of intraoperative margins in resource limited environments and reducing the number of frozen section biopsies performed. Further by providing real-time clinical information within minutes it can reduce indirect costs such as operating room time. It may also be used as an ad hoc for frozen section biopsies where frozen section facilities are available. PMID:22500814

  5. SU-F-T-394: Impact of PTV Margins With Taking Into Account Shape Variation On IMRT Plans For Prostate Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirose, T; Arimura, H; Oga, S

    2016-06-15

    Purpose: The purpose of this study was to investigate the impact of planning target volume (PTV) margins with taking into consideration clinical target volume (CTV) shape variations on treatment plans of intensity modulated radiation therapy (IMRT) for prostate cancer. Methods: The systematic errors and the random errors for patient setup errors in right-left (RL), anterior-posterior (AP), and superior-inferior (SI) directions were obtained from data of 20 patients, and those for CTV shape variations were calculated from 10 patients, who were weekly scanned using cone beam computed tomography (CBCT). The setup error was defined as the difference in prostate centers betweenmore » planning CT and CBCT images after bone-based registrations. CTV shape variations of high, intermediate and low risk CTVs were calculated for each patient from variances of interfractional shape variations on each vertex of three-dimensional CTV point distributions, which were manually obtained from CTV contours on the CBCT images. PTV margins were calculated using the setup errors with and without CTV shape variations for each risk CTV. Six treatment plans were retrospectively made by using the PTV margins with and without CTV shape variations for the three risk CTVs of 5 test patients. Furthermore, the treatment plans were applied to CBCT images for investigating the impact of shape variations on PTV margins. Results: The percentages of population to cover with the PTV, which satisfies the CTV D98 of 95%, with and without the shape variations were 89.7% and 74.4% for high risk, 89.7% and 76.9% for intermediate risk, 84.6% and 76.9% for low risk, respectively. Conclusion: PTV margins taking into account CTV shape variation provide significant improvement of applicable percentage of population (P < 0.05). This study suggested that CTV shape variation should be taken consideration into determination of the PTV margins.« less

  6. Targeted Maximum Likelihood Estimation for Dynamic and Static Longitudinal Marginal Structural Working Models

    PubMed Central

    Schwab, Joshua; Gruber, Susan; Blaser, Nello; Schomaker, Michael; van der Laan, Mark

    2015-01-01

    This paper describes a targeted maximum likelihood estimator (TMLE) for the parameters of longitudinal static and dynamic marginal structural models. We consider a longitudinal data structure consisting of baseline covariates, time-dependent intervention nodes, intermediate time-dependent covariates, and a possibly time-dependent outcome. The intervention nodes at each time point can include a binary treatment as well as a right-censoring indicator. Given a class of dynamic or static interventions, a marginal structural model is used to model the mean of the intervention-specific counterfactual outcome as a function of the intervention, time point, and possibly a subset of baseline covariates. Because the true shape of this function is rarely known, the marginal structural model is used as a working model. The causal quantity of interest is defined as the projection of the true function onto this working model. Iterated conditional expectation double robust estimators for marginal structural model parameters were previously proposed by Robins (2000, 2002) and Bang and Robins (2005). Here we build on this work and present a pooled TMLE for the parameters of marginal structural working models. We compare this pooled estimator to a stratified TMLE (Schnitzer et al. 2014) that is based on estimating the intervention-specific mean separately for each intervention of interest. The performance of the pooled TMLE is compared to the performance of the stratified TMLE and the performance of inverse probability weighted (IPW) estimators using simulations. Concepts are illustrated using an example in which the aim is to estimate the causal effect of delayed switch following immunological failure of first line antiretroviral therapy among HIV-infected patients. Data from the International Epidemiological Databases to Evaluate AIDS, Southern Africa are analyzed to investigate this question using both TML and IPW estimators. Our results demonstrate practical advantages of the pooled TMLE over an IPW estimator for working marginal structural models for survival, as well as cases in which the pooled TMLE is superior to its stratified counterpart. PMID:25909047

  7. Genital marginal failures after intensity-modulated radiation therapy (IMRT) in squamous cell anal cancer: no higher risk with IMRT when compared to 3DCRT.

    PubMed

    Dell'Acqua, V; Kobiela, J; Kraja, F; Leonardi, M C; Surgo, A; Zerella, M A; Arculeo, S; Fodor, C; Ricotti, R; Zampino, M G; Ravenda, S; Spinoglio, G; Biffi, R; Bazani, A; Luraschi, R; Vigorito, S; Spychalski, P; Orecchia, R; Glynne-Jones, R; Jereczek-Fossa, B A

    2018-03-28

    Intensity-modulated radiotherapy (IMRT) is considered the preferred option in squamous cell canal cancer (SCAC), delivering high doses to tumor volumes while minimizing dose to surrounding normal tissues. IMRT has steep dose gradients, but the technique is more demanding as deep understanding of target structures is required. To evaluate genital marginal failure in a cohort of patients with non-metastatic SCAC treated either with IMRT or 3DCRT and concurrent chemotherapy, 117 patients with SCAC were evaluated: 64 and 53 patients were treated with IMRT and 3DCRT techniques, respectively. All patients underwent clinical and radiological examination during their follow-up. Tumor response was evaluated with response evaluation criteria in solid tumors v1.1 guideline on regular basis. All patients' data were analyzed, and patients with marginal failure were identified. Concomitant chemotherapy was administered in 97 and 77.4% of patients in the IMRT and 3DCRT groups, respectively. In the IMRT group, the median follow-up was 25 months (range 6-78). Progressive disease was registered in 15.6% of patients; infield recurrence, distant recurrence and both infield recurrence and distant recurrence were identified in 5, 4 and 1 patient, respectively. Two out of 64 patients (3.1%) had marginal failures, localized at vagina/recto-vaginal septum and left perineal region. In the 3DCRT group, the median follow-up was 71.3 months (range 6-194 months). Two out of 53 patients (3.8%) had marginal failures, localized at recto-vaginal septum and perigenital structures. The rate of marginal failures was comparable in IMRT and 3DCRT groups (χ 2 test p = 0.85). In this series, the use of IMRT for the treatment of SCAC did not increase the rate of marginal failures offering improved dose conformity to the target. Dose constraints should be applied with caution-particularly in females with involvement of the vagina or the vaginal septum.

  8. Target margins in radiotherapy of prostate cancer

    PubMed Central

    Bauman, Glenn

    2016-01-01

    We reviewed the literature on the use of margins in radiotherapy of patients with prostate cancer, focusing on different options for image guidance (IG) and technical issues. The search in PubMed database was limited to include studies that involved external beam radiotherapy of the intact prostate. Post-prostatectomy studies, brachytherapy and particle therapy were excluded. Each article was characterized according to the IG strategy used: positioning on external marks using room lasers, bone anatomy and soft tissue match, usage of fiducial markers, electromagnetic tracking and adapted delivery. A lack of uniformity in margin selection among institutions was evident from the review. In general, introduction of pre- and in-treatment IG was associated with smaller planning target volume (PTV) margins, but there was a lack of definitive experimental/clinical studies providing robust information on selection of exact PTV values. In addition, there is a lack of comparative research regarding the cost–benefit ratio of the different strategies: insertion of fiducial markers or electromagnetic transponders facilitates prostate gland localization but at a price of invasive procedure; frequent pre-treatment imaging increases patient in-room time, dose and labour; online plan adaptation should improve radiation delivery accuracy but requires fast and precise computation. Finally, optimal protocols for quality assurance procedures need to be established. PMID:27377353

  9. Role of specimen US for predicting resection margin status in breast conserving therapy

    PubMed Central

    MOSCHETTA, M.; TELEGRAFO, M.; INTRONA, T.; COI, L.; RELLA, L.; RANIERI, V.; CIRILLI, A.; IANORA, A.A. STABILE; ANGELELLI, G.

    2015-01-01

    Aim To assess the diagnostic accuracy of specimen ultrasound (US) for predicting resection margin status in women undergoing breast conserving therapy for US-detected cancer, having the histological findings as the reference standard. Patients and methods A total of 132 consecutive patients (age range, 34–87 years; mean, 51 years) underwent breast-conserving surgery for US-detected invasive breast cancer. All surgical specimens underwent US examination. The presence of lesion within the specimen and its distance from the specimen margins were assessed considering a threshold distance between the lesion and specimen margins of 10 mm. US findings were then compared with the pathological ones and specimen US. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) for predicting histological margin status were evaluated, having the histological findings as the reference standard. Results The histological examination detected invasive ductal carcinoma in 96/132 (73%) cases, invasive lobular carcinoma in 32/132 (24%), mucinous carcinoma in 4/132 (3%). The pathological margin analysis revealed 96/132 (73%) negative margins and 36 (27%) close/positive margins. US examination detected all 132 breast lesions within the surgical specimens. 110 (83%) negative margins and 22 (17%) positive margins were found on US. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 44%, 94%, 80%, 73% and 82%, respectively, were found for specimen US. Conclusions Specimen US represents a time and cost saving imaging tool for evaluating the presence of US detected-breast lesion within surgical specimen and for predicting the histological margin status. PMID:26712255

  10. Parenting for the promotion of adolescent mental health: a scoping review of programmes targeting ethnoculturally diverse families.

    PubMed

    Ruiz-Casares, Mónica; Drummond, Jennifer D; Beeman, Irene; Lach, Lucyna M

    2017-03-01

    A scoping review of the literature on parenting programmes that target the promotion of adolescent mental health was conducted to examine the quality of the studies and unique content of programmes for parents from ethnoculturally diverse communities. PsycINFO and Web of Science were searched in April, 2011 (for all publications prior to that date) and again in August, 2015 (for publications from April, 2011 to August, 2015) using specific keywords and inclusion criteria. A hand search was also conducted. Overall, 107 studies met inclusion criteria for final data extraction and included evaluations of interventions targeted at substance use, early/risky sexual activity and behavioural problems. Eighteen of the 107 studies described programmes targeting parents of adolescents from diverse ethnocultural communities; the quality of these 18 studies was assessed using a marginally modified version of the Downs and Black Checklist (Downs & Black 1998). Their average quality assessment score was 16 out of 28. In addition, two key themes reflected in successful interventions emerged: strengthening parent-adolescent relationship through communication, and importance of community engagement in designing and implementing the intervention. Findings indicate gaps in service delivery to parents of adolescents from ethnoculturally diverse communities; there are a limited number of studies on programmes targeting ethnoculturally diverse parents of adolescents, and the quality of studies that do exist is overall low. Given increasing diversity, more emphasis should be placed on developing and modifying programmes to meet the needs of ethnoculturally diverse communities. More rigorous, standardised efforts should be made to evaluate programmes that do exist. © 2016 John Wiley & Sons Ltd.

  11. Flight assessment of the onboard propulsion system model for the Performance Seeking Control algorithm on an F-15 aircraft

    NASA Technical Reports Server (NTRS)

    Orme, John S.; Schkolnik, Gerard S.

    1995-01-01

    Performance Seeking Control (PSC), an onboard, adaptive, real-time optimization algorithm, relies upon an onboard propulsion system model. Flight results illustrated propulsion system performance improvements as calculated by the model. These improvements were subject to uncertainty arising from modeling error. Thus to quantify uncertainty in the PSC performance improvements, modeling accuracy must be assessed. A flight test approach to verify PSC-predicted increases in thrust (FNP) and absolute levels of fan stall margin is developed and applied to flight test data. Application of the excess thrust technique shows that increases of FNP agree to within 3 percent of full-scale measurements for most conditions. Accuracy to these levels is significant because uncertainty bands may now be applied to the performance improvements provided by PSC. Assessment of PSC fan stall margin modeling accuracy was completed with analysis of in-flight stall tests. Results indicate that the model overestimates the stall margin by between 5 to 10 percent. Because PSC achieves performance gains by using available stall margin, this overestimation may represent performance improvements to be recovered with increased modeling accuracy. Assessment of thrust and stall margin modeling accuracy provides a critical piece for a comprehensive understanding of PSC's capabilities and limitations.

  12. Dosimetric and geometric evaluation of a hybrid strategy of offline adaptive planning and online image guidance for prostate cancer radiotherapy

    PubMed Central

    Liu, Han; Wu, Qiuwen

    2011-01-01

    For prostate cancer patients, online image-guided (IG) radiotherapy has been widely used in clinic to correct the translational inter-fractional motion at each treatment fraction. For uncertainties that cannot be corrected online, such as rotation and deformation of the target volume, margins are still required to be added to the clinical target volume (CTV) for the treatment planning. Offline adaptive radiotherapy has been implemented to optimize the treatment for each individual patient based on the measurements at early stages of treatment process. It has been shown that offline adaptive radiotherapy can effectively reduce the required margin. Recently a hybrid strategy of offline adaptive replanning and online IG was proposed and the geometric evaluation was performed. It was found that the planning margins can be further reduced by 1–2 mm compared to online IG only strategy. The purpose of this study was to investigate the dosimetric benefits of such hybrid strategy on the target and organs at risk (OARs). A total of 420 repeated helical computed tomography (HCT) scans from 28 patients were included in the study. Both low-risk patients (LRP, CTV = prostate) and intermediate-risk patients (IRP, CTV = prostate + seminal vesicles, SV) were included in the simulation. Two registration methods, based on center-of-mass (COM) shift of prostate only and prostate plus SV, were performed for IRP. The intensity modulated radiotherapy (IMRT) was used in the simulation. Criteria on both cumulative dose and fractional doses were evaluated. Furthermore, the geometric evaluation was extended to investigate the optimal number of fractions necessary to construct the internal target volume (ITV) for the hybrid strategy. The dosimetric margin improvement was smaller than its geometric counterpart and was in the range of 0 mm to 1 mm. The optimal number of fractions necessary for the ITV construction is 2 for LRP and 3–4 for IRP in a hypofractionation protocol. A new cumulative index of target volume (CITV) was proposed for the evaluation of adaptive radiotherapy strategies, and it was found that it had the advantages over other indices in evaluating different adaptive radiotherapy strategies. PMID:21772083

  13. Dosimetric and geometric evaluation of a hybrid strategy of offline adaptive planning and online image guidance for prostate cancer radiotherapy.

    PubMed

    Liu, Han; Wu, Qiuwen

    2011-08-07

    For prostate cancer patients, online image-guided (IG) radiotherapy has been widely used in clinic to correct the translational inter-fractional motion at each treatment fraction. For uncertainties that cannot be corrected online, such as rotation and deformation of the target volume, margins are still required to be added to the clinical target volume (CTV) for the treatment planning. Offline adaptive radiotherapy has been implemented to optimize the treatment for each individual patient based on the measurements at early stages of treatment process. It has been shown that offline adaptive radiotherapy can effectively reduce the required margin. Recently a hybrid strategy of offline adaptive replanning and online IG was proposed and the geometric evaluation was performed. It was found that the planning margins can further be reduced by 1-2 mm compared to online IG only strategy. The purpose of this study was to investigate the dosimetric benefits of such a hybrid strategy on the target and organs at risk. A total of 420 repeated helical computed tomography scans from 28 patients were included in the study. Both low-risk patients (LRP, CTV = prostate) and intermediate-risk patients (IRP, CTV = prostate + seminal vesicles, SV) were included in the simulation. Two registration methods, based on center-of-mass shift of prostate only and prostate plus SV, were performed for IRP. The intensity-modulated radiotherapy was used in the simulation. Criteria on both cumulative and fractional doses were evaluated. Furthermore, the geometric evaluation was extended to investigate the optimal number of fractions necessary to construct the internal target volume (ITV) for the hybrid strategy. The dosimetric margin improvement was smaller than its geometric counterpart and was in the range of 0-1 mm. The optimal number of fractions necessary for the ITV construction is 2 for LRPs and 3-4 for IRPs in a hypofractionation protocol. A new cumulative index of target volume was proposed for the evaluation of adaptive radiotherapy strategies, and it was found that it had the advantages over other indices in evaluating different adaptive radiotherapy strategies.

  14. Applied Time Domain Stability Margin Assessment for Nonlinear Time-Varying Systems

    NASA Technical Reports Server (NTRS)

    Kiefer, J. M.; Johnson, M. D.; Wall, J. H.; Dominguez, A.

    2016-01-01

    The baseline stability margins for NASA's Space Launch System (SLS) launch vehicle were generated via the classical approach of linearizing the system equations of motion and determining the gain and phase margins from the resulting frequency domain model. To improve the fidelity of the classical methods, the linear frequency domain approach can be extended by replacing static, memoryless nonlinearities with describing functions. This technique, however, does not address the time varying nature of the dynamics of a launch vehicle in flight. An alternative technique for the evaluation of the stability of the nonlinear launch vehicle dynamics along its trajectory is to incrementally adjust the gain and/or time delay in the time domain simulation until the system exhibits unstable behavior. This technique has the added benefit of providing a direct comparison between the time domain and frequency domain tools in support of simulation validation. This technique was implemented by using the Stability Aerospace Vehicle Analysis Tool (SAVANT) computer simulation to evaluate the stability of the SLS system with the Adaptive Augmenting Control (AAC) active and inactive along its ascent trajectory. The gains for which the vehicle maintains apparent time-domain stability defines the gain margins, and the time delay similarly defines the phase margin. This method of extracting the control stability margins from the time-domain simulation is relatively straightforward and the resultant margins can be compared to the linearized system results. The sections herein describe the techniques employed to extract the time-domain margins, compare the results between these nonlinear and the linear methods, and provide explanations for observed discrepancies. The SLS ascent trajectory was simulated with SAVANT and the classical linear stability margins were evaluated at one second intervals. The linear analysis was performed with the AAC algorithm disabled to attain baseline stability margins. At each time point, the system was linearized about the current operating point using Simulink's built-in solver. Each linearized system in time was evaluated for its rigid-body gain margin (high frequency gain margin), rigid-body phase margin, and aero gain margin (low frequency gain margin) for each control axis. Using the stability margins derived from the baseline linearization approach, the time domain derived stability margins were determined by executing time domain simulations in which axis-specific incremental gain and phase adjustments were made to the nominal system about the expected neutral stability point at specific flight times. The baseline stability margin time histories were used to shift the system gain to various values around the zero margin point such that a precise amount of expected gain margin was maintained throughout flight. When assessing the gain margins, the gain was applied starting at the time point under consideration, thereafter following the variation in the margin found in the linear analysis. When assessing the rigid-body phase margin, a constant time delay was applied to the system starting at the time point under consideration. If the baseline stability margins were correctly determined via the linear analysis, the time domain simulation results should contain unstable behavior at certain gain and phase values. Examples will be shown from repeated simulations with variable added gain and phase lag. Faithfulness of margins calculated from the linear analysis to the nonlinear system will be demonstrated.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peulen, Heike; Mantel, Frederick; Department of Radiation Oncology, University Hospital Zurich, Zurich

    Purpose: Fibrotic changes after stereotactic body radiation therapy (SBRT) for stage I non-small cell lung cancer (NSCLC) are difficult to distinguish from local recurrences (LR), hampering proper patient selection for salvage therapy. This study validates previously reported high-risk computed tomography (CT) features (HRFs) for detection of LR in an independent patient cohort. Methods and Materials: From a multicenter database, 13 patients with biopsy-proven LR were matched 1:2 to 26 non-LR control patients based on dose, planning target volume (PTV), follow-up time, and lung lobe. Tested HRFs were enlarging opacity, sequential enlarging opacity, enlarging opacity after 12 months, bulging margin, linear marginmore » disappearance, loss of air bronchogram, and craniocaudal growth. Additionally, 2 new features were analyzed: the occurrence of new unilateral pleural effusion, and growth based on relative volume, assessed by manual delineation. Results: All HRFs were significantly associated with LR except for loss of air bronchogram. The best performing HRFs were bulging margin, linear margin disappearance, and craniocaudal growth. Receiver operating characteristic analysis of the number of HRFs to detect LR had an area under the curve (AUC) of 0.97 (95% confidence interval [CI] 0.9-1.0), which was identical to the performance described in the original report. The best compromise (closest to 100% sensitivity and specificity) was found at ≥4 HRFs, with a sensitivity of 92% and a specificity of 85%. A model consisting of only 2 HRFs, bulging margin and craniocaudal growth, resulted in a sensitivity of 85% and a specificity of 100%, with an AUC of 0.96 (95% CI 0.9-1.0) (HRFs ≥2). Pleural effusion and relative growth did not significantly improve the model. Conclusion: We successfully validated CT-based HRFs for detection of LR after SBRT for early-stage NSCLC. As an alternative to number of HRFs, we propose a simplified model with the combination of the 2 best HRFs: bulging margin and craniocaudal growth, although validation is warranted.« less

  16. Comparison of pencil beam–based homogeneous vs inhomogeneous target dose planning for stereotactic body radiotherapy of peripheral lung tumors through Monte Carlo–based recalculation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ohtakara, Kazuhiro, E-mail: ohtakara@murakami.asahi-u.ac.jp; Hoshi, Hiroaki

    2015-10-01

    This study was conducted to ascertain whether homogeneous target dose planning is suitable for stereotactic body radiotherapy (SBRT) of peripheral lung cancer under appropriate breath-holding. For 20 peripheral lung tumors, paired dynamic conformal arc plans were generated by only adjusting the leaf margin to the planning target volume (PTV) edge for fulfilling the conditions such that the prescription isodose surface (IDS) encompassing exactly 95% of the PTV (PTV D{sub 95}) corresponds to 95% and 80% IDS, normalized to 100% at the PTV isocenter under a pencil beam (PB) algorithm with radiologic path length correction. These plans were recalculated using themore » x-ray voxel Monte Carlo (XVMC) algorithm under otherwise identical conditions, and then compared. Lesions abutting the parietal pleura or not were defined as edge or island tumors, respectively, and the influences of the target volume and its location relative to the chest wall on the target dose were examined. The median (range) leaf margin required for the 95% and 80% plans was 3.9 mm (1.3 to 5.0) and −1.2 mm (−1.8 to 0.1), respectively. Notably, the latter was significantly correlated negatively with PTV. In the 80% plans, the PTV D{sub 95} was slightly higher under XVMC, whereas the PTV D{sub 98} was significantly lower, irrespective of the dose calculation algorithm used. Other PTV and all gross tumor volume doses were significantly higher, while the lung doses outside the PTV were slightly lower. The target doses increased as a function of PTV and were significantly lower for island tumors than for edge tumors. In conclusion, inhomogeneous target dose planning using smaller leaf margin for a larger tumor volume was deemed suitable in ensuring more sufficient target dose while slightly reducing lung dose. In addition, more inhomogeneous target dose planning using <80% IDS (e.g., 70%) for PTV covering would be preferable for island tumors.« less

  17. Effect of Body Mass Index on Magnitude of Setup Errors in Patients Treated With Adjuvant Radiotherapy for Endometrial Cancer With Daily Image Guidance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Lilie L., E-mail: lin@uphs.upenn.edu; Hertan, Lauren; Rengan, Ramesh

    2012-06-01

    Purpose: To determine the impact of body mass index (BMI) on daily setup variations and frequency of imaging necessary for patients with endometrial cancer treated with adjuvant intensity-modulated radiotherapy (IMRT) with daily image guidance. Methods and Materials: The daily shifts from a total of 782 orthogonal kilovoltage images from 30 patients who received pelvic IMRT between July 2008 and August 2010 were analyzed. The BMI, mean daily shifts, and random and systematic errors in each translational and rotational direction were calculated for each patient. Margin recipes were generated based on BMI. Linear regression and spearman rank correlation analysis were performed.more » To simulate a less-than-daily IGRT protocol, the average shift of the first five fractions was applied to subsequent setups without IGRT for assessing the impact on setup error and margin requirements. Results: Median BMI was 32.9 (range, 23-62). Of the 30 patients, 16.7% (n = 5) were normal weight (BMI <25); 23.3% (n = 7) were overweight (BMI {>=}25 to <30); 26.7% (n = 8) were mildly obese (BMI {>=}30 to <35); and 33.3% (n = 10) were moderately to severely obese (BMI {>=} 35). On linear regression, mean absolute vertical, longitudinal, and lateral shifts positively correlated with BMI (p = 0.0127, p = 0.0037, and p < 0.0001, respectively). Systematic errors in the longitudinal and vertical direction were found to be positively correlated with BMI category (p < 0.0001 for both). IGRT for the first five fractions, followed by correction of the mean error for all subsequent fractions, led to a substantial reduction in setup error and resultant margin requirement overall compared with no IGRT. Conclusions: Daily shifts, systematic errors, and margin requirements were greatest in obese patients. For women who are normal or overweight, a planning target margin margin of 7 to 10 mm may be sufficient without IGRT, but for patients who are moderately or severely obese, this is insufficient.« less

  18. A tissue dose-based comparative exposure assessment of manganese using physiologically based pharmacokinetic modeling—The importance of homeostatic control for an essential metal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gentry, P. Robinan, E-mail: rgentry@ramboll.com

    A physiologically-based pharmacokinetic (PBPK) model (Schroeter et al., 2011) was applied to simulate target tissue manganese (Mn) concentrations following occupational and environmental exposures. These estimates of target tissue Mn concentrations were compared to determine margins of safety (MOS) and to evaluate the biological relevance of applying safety factors to derive acceptable Mn air concentrations. Mn blood concentrations measured in occupational studies permitted verification of the human PBPK models, increasing confidence in the resulting estimates. Mn exposure was determined based on measured ambient air Mn concentrations and dietary data in Canada and the United States (US). Incorporating dietary and inhalation exposuresmore » into the models indicated that increases in target tissue concentrations above endogenous levels only begin to occur when humans are exposed to levels of Mn in ambient air (i.e. > 10 μg/m{sup 3}) that are far higher than those currently measured in Canada or the US. A MOS greater than three orders of magnitude was observed, indicating that current Mn air concentrations are far below concentrations that would be required to produce the target tissue Mn concentrations associated with subclinical neurological effects. This application of PBPK modeling for an essential element clearly demonstrates that the conventional application of default factors to “convert” an occupational exposure to an equivalent continuous environmental exposure, followed by the application of safety factors, is not appropriate in the case of Mn. PBPK modeling demonstrates that the relationship between ambient Mn exposures and dose-to-target tissue is not linear due to normal tissue background levels and homeostatic controls. - Highlights: • Manganese is an essential nutrient, adding complexity to its risk assessment. • Nonlinearities in biological processes are important for manganese risk assessment. • A PBPK model was used to estimate target tissue concentrations of manganese. • An MOS approach also considered target tissue concentrations for ambient exposures. • Relationships between ambient Mn exposures and dose-to-target tissue are not linear.« less

  19. [The dynamics of blood circulation in marginal gingiva after crown preparation by different ledge locations].

    PubMed

    Shcherbakov, A S; Kuznetsova, M B; Kuznetsov, D L; Ivanova, S B

    2013-01-01

    The periodontal tissue level may change after gingival margin retraction and tooth preparation. The aim of the study was to assess the influence of these manipulations on the condition of free gingival margin. The study included 53 persons (29 women and 24 men) divided into 4 groups followed-up for 6 to 8 weeks. Blood circulation in marginal gingiva of 118 teeth with healthy periodontal tissues was assessed by ultrasonic Doppler evaluation to reveal the circulation impairments in cervical margin after teeth crown preparation. The first group included 39 teeth, in which the gum was retracted by Roeko stay put non impregna cords ("Langenau", Germany). The second group included 39 teeth with shoulders prepared at the gingival margin; in the third group (40 teeth) the shoulder was located subgingivally. The fourth group (40 teeth) was control. The changes in recovery indices have been analyzed. The linear values were established as most significant and demonstrative. The indices variations and recovery period length depended on the coronal edge location. Statistically significant differences were found among all the groups (p>0.05). The results may be used to improve crown preparation for fixed dentures and decrease the recession rate of free gingival margin.

  20. In vitro analysis of the marginal adaptation and discrepancy of stainless steel crowns

    PubMed Central

    Mulder, Riaan; Medhat, Rasha; Mohamed, Nadia

    2018-01-01

    Abstract Aim: The purpose of the study was to assess the marginal adaptation and discrepancy of SSC’s. Differences in adaptation and discrepancy between the four surfaces (mesial, lingual, distal, and buccal) were evaluated. Methods: The placement of stainless steel crowns were completed on a phantom head in accordance with the clinical technique. The ideal tooth preparation was made and this ‘master tooth’ duplicated to achieve a sample size of 15. The stainless steel crowns were placed, trimmed, and cemented as per the clinical technique. The cemented stainless crowns were analyzed under 100× stereomicroscope magnification. The marginal adaptation and discrepancy of each specimen was measured every 2 µm. Results: All the specimens showed marginal adaptation and discrepancy. The lingual margin had a significantly better adaptation (p < .0001) over the other surfaces. The buccal surface was the only surface that had an appropriate supra-CEJ level with a significance of p < .0001. Conclusion: The marginal discrepancies occur during the trimming procedure and assessment of the gingival approximation of the SSC margin. The inspection of stainless steel crown adaptation and discrepancy is an essential clinical step. PMID:29536024

  1. Plan selection strategy for rectum cancer patients: An interobserver study to assess clinical feasibility.

    PubMed

    de Jong, Rianne; Lutkenhaus, Lotte; van Wieringen, Niek; Visser, Jorrit; Wiersma, Jan; Crama, Koen; Geijsen, Debby; Bel, Arjan

    2016-08-01

    In radiotherapy for rectum cancer, the target volume is highly deformable. An adaptive plan selection strategy can mitigate the effect of these variations. The purpose of this study was to evaluate the feasibility of an adaptive strategy by assessing the interobserver variation in CBCT-based plan selection. Eleven patients with rectum cancer, treated with a non-adaptive strategy, were selected. Five CBCT scans were available per patient. To simulate the plan selection strategy, per patient three PTVs were created by varying the anterior upper mesorectum margin. For each CBCT scan, twenty observers selected the smallest PTV that encompassed the target volume. After this initial baseline measurement, the gold standard was determined during a consensus meeting, followed by a second measurement one month later. Differences between both measurements were assessed using the Wilcoxon signed-rank test. In the baseline measurement, the concordance with the gold standard was 69% (range: 60-82%), which improved to 75% (range: 60-87%) in the second measurement (p=0.01). For the second measurement, 10% of plan selections were smaller than the gold standard. With a plan selection consistency between observers of 75%, a plan selection strategy for rectum cancer patients is feasible. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Positive surgical margins in robot-assisted partial nephrectomy: a multi-institutional analysis of oncologic outcomes (leave no tumor behind).

    PubMed

    Khalifeh, Ali; Kaouk, Jihad H; Bhayani, Sam; Rogers, Craig; Stifelman, Michael; Tanagho, Youssef S; Kumar, Ramesh; Gorin, Michael A; Sivarajan, Ganesh; Samarasekera, Dinesh; Allaf, Mohamad E

    2013-11-01

    Expanding indications for robot-assisted partial nephrectomy raise major oncologic concerns for positive surgical margins. Previous reports showed no correlation between positive surgical margins and oncologic outcomes. We report a multi-institutional experience with the oncologic outcomes of positive surgical margins on robot-assisted partial nephrectomy. Pathological and clinical followup data were reviewed from an institutional review board approved, prospectively maintained joint database from 5 institutions. Tumors with malignant pathology were isolated and statistically analyzed for demographics and oncologic followup. The log rank test was used to compare recurrence-free and metastasis-free survival between patients with positive and negative surgical margins. The proportional hazards method was used to assess the influence of multiple factors, including positive surgical margins, on recurrence and metastasis. A total of 943 robot-assisted partial nephrectomies for malignant tumors were successfully completed. Of the patients 21 (2.2%) had positive surgical margins on final pathological assessment, resulting in 2 groups, including the 21 with positive surgical margins and 922 with negative surgical margins. Positive surgical margin cases had higher recurrence and metastasis rates (p<0.001). As projected by the Kaplan-Meier method in the population as a whole at followup out to 63.6 months, 5-year recurrence-free and metastasis-free survival was 94.8% and 97.5%, respectively. There was a statistically significant difference in recurrence-free and metastasis-free survival between patients with positive and negative surgical margins (log rank test<0.001), which favored negative surgical margins. Positive surgical margins showed an 18.4-fold higher HR for recurrence when adjusted for multiple tumors, tumor size, tumor growth pattern and pathological stage. Positive surgical margins on final pathological evaluation increase the HR of recurrence and metastasis. In addition to pathological and molecular tumor characteristics, this should be considered to plan appropriate management. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  3. Inserting ex vivo fluorescence confocal microscopy perioperatively in Mohs micrographic surgery expedites bedside assessment of excision margins in recurrent basal cell carcinoma.

    PubMed

    Longo, Caterina; Ragazzi, Moira; Castagnetti, Fabio; Gardini, Stefano; Palmieri, Tamara; Lallas, Aimilios; Moscarella, Elvira; Piana, Simonetta; Pellacani, Giovanni; Zalaudek, Iris; Argenziano, Giuseppe

    2013-01-01

    Mohs micrographic surgery can be employed in recurrent basal cell carcinoma, although it is a time-consuming technique. Recently, ex vivo fluorescence confocal microscopy (FCM) has been employed to obtain a fast assessment of tumor margins at the bedside. In our case we successfully employed ex vivo FCM to assess the tumor margins and we treated the persistent tumor with intensity-modulated radiation therapy. Our case demonstrates that a multidisciplinary approach is very efficient in managing complex and recurrent tumors and highlights the benefits of FCM as a new technique that can be used in the surgical theater to speed up the entire procedure.

  4. Ecological risk assessment for DvSnf7 RNA: A plant-incorporated protectant with targeted activity against western corn rootworm.

    PubMed

    Bachman, Pamela M; Huizinga, Kristin M; Jensen, Peter D; Mueller, Geoffrey; Tan, Jianguo; Uffman, Joshua P; Levine, Steven L

    2016-11-01

    MON 87411 maize, which expresses DvSnf7 RNA, was developed to provide an additional mode of action to confer protection against corn rootworm (Diabrotica spp.). A critical step in the registration of a genetically engineered crop with an insecticidal trait is performing an ecological risk assessment to evaluate the potential for adverse ecological effects. For MON 87411, an assessment plan was developed that met specific protection goals by characterizing the routes and levels of exposure, and testing representative functional taxa that would be directly or indirectly exposed in the environment. The potential for toxicity of DvSnf7 RNA was evaluated with a harmonized battery of non-target organisms (NTOs) that included invertebrate predators, parasitoids, pollinators, soil biota as well as aquatic and terrestrial vertebrate species. Laboratory tests evaluated ecologically relevant endpoints such as survival, growth, development, and reproduction and were of sufficient duration to assess the potential for adverse effects. No adverse effects were observed with any species tested at, or above, the maximum expected environmental concentration (MEEC). All margins of exposure for NTOs were >10-fold the MEEC. Therefore, it is reasonable to conclude that exposure to DvSnf7 RNA, both directly and indirectly, is safe for NTOs at the expected field exposure levels. Copyright © 2016 The Author(s). Published by Elsevier Inc. All rights reserved.

  5. Early-time radiation flux symmetry optimization and its effect on gas-filled hohlraum ignition targets on the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Milovich, J. L.; Dewald, E. L.; Pak, A.; Michel, P.; Town, R. P. J.; Bradley, D. K.; Landen, O.; Edwards, M. J.

    2016-03-01

    Achieving ignition on the National Ignition Facility (NIF) is tied to our ability to control and minimize deviations from sphericity of the capsule implosion. Low-mode asymmetries of the hot spot result from the combined effect of radiation drive asymmetries throughout the laser pulse and initial roughness on the capsule surface. In this paper, we report on simulations and experiments designed to assess, measure, and correct the drive asymmetries produced by the early-time (≈first 2 ns or "picket") period of the laser pulse. The drive asymmetry during the picket is commonly thought to introduce distortions in the hot-spot shape at ignition time. However, a more subtle effect not previously considered is that it also leads to an asymmetry in shock velocity and timing, thereby increasing the fuel adiabat and reducing the margin for ignition. It is shown via hydrodynamic simulations that minimizing this effect requires that the early-time asymmetry be kept below 7.5% in the second Legendre mode (P2), thus keeping the loss of performance margin below ≈10% for a layered implosion. Asymmetries during the picket of the laser pulse are measured using the instantaneous self-emission of a high-Z re-emission sphere in place of an ignition capsule in a hohlraum with large azimuthal diagnostic windows. Three dimensional simulations using the code HYDRA (to capture the effect of non-azimuthal hohlraum features) coupled to a cross-beam energy transfer model [Michel et al., Phys. Plasmas 17, 056305 (2010)] are used to establish the surrogacy of the re-emit target and to assess the early-time drive symmetry. Calculations using this model exhibit the same sensitivity to variations in the relative input powers between the different cones of NIF beams as measured for the "Rev5" CH target [Haan et al., Phys Plasmas 18, 051001 (2011)] and reported by Dewald et al. [Phys. Rev. Lett. 111, 235001 (2013)]. The same methodology applied to recently improved implosions using different hohlraum geometries and picket powers show good agreement with experimental data.

  6. Early-time radiation flux symmetry optimization and its effect on gas-filled hohlraum ignition targets on the National Ignition Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Milovich, J. L., E-mail: milovich1@llnl.gov; Dewald, E. L.; Pak, A.

    2016-03-15

    Achieving ignition on the National Ignition Facility (NIF) is tied to our ability to control and minimize deviations from sphericity of the capsule implosion. Low-mode asymmetries of the hot spot result from the combined effect of radiation drive asymmetries throughout the laser pulse and initial roughness on the capsule surface. In this paper, we report on simulations and experiments designed to assess, measure, and correct the drive asymmetries produced by the early-time (≈first 2 ns or “picket”) period of the laser pulse. The drive asymmetry during the picket is commonly thought to introduce distortions in the hot-spot shape at ignition time.more » However, a more subtle effect not previously considered is that it also leads to an asymmetry in shock velocity and timing, thereby increasing the fuel adiabat and reducing the margin for ignition. It is shown via hydrodynamic simulations that minimizing this effect requires that the early-time asymmetry be kept below 7.5% in the second Legendre mode (P{sub 2}), thus keeping the loss of performance margin below ≈10% for a layered implosion. Asymmetries during the picket of the laser pulse are measured using the instantaneous self-emission of a high-Z re-emission sphere in place of an ignition capsule in a hohlraum with large azimuthal diagnostic windows. Three dimensional simulations using the code HYDRA (to capture the effect of non-azimuthal hohlraum features) coupled to a cross-beam energy transfer model [Michel et al., Phys. Plasmas 17, 056305 (2010)] are used to establish the surrogacy of the re-emit target and to assess the early-time drive symmetry. Calculations using this model exhibit the same sensitivity to variations in the relative input powers between the different cones of NIF beams as measured for the “Rev5” CH target [Haan et al., Phys Plasmas 18, 051001 (2011)] and reported by Dewald et al. [Phys. Rev. Lett. 111, 235001 (2013)]. The same methodology applied to recently improved implosions using different hohlraum geometries and picket powers show good agreement with experimental data.« less

  7. Characterization of spatial distortion in a 0.35 T MRI-guided radiotherapy system

    NASA Astrophysics Data System (ADS)

    Ginn, John S.; Agazaryan, Nzhde; Cao, Minsong; Baharom, Umar; Low, Daniel A.; Yang, Yingli; Gao, Yu; Hu, Peng; Lee, Percy; Lamb, James M.

    2017-06-01

    Spatial distortion results in image deformation that can degrade accurate targeting and dose calculations in MRI-guided adaptive radiotherapy. The authors present a comprehensive assessment of a 0.35 T MRI-guided radiotherapy system’s spatial distortion using two commercially-available phantoms with regularly spaced markers. Images of the spatial integrity phantoms were acquired using five clinical protocols on the MRI-guided radiotherapy machine with the radiotherapy gantry positioned at various angles. Software was developed to identify and localize all phantom markers using a template matching approach. Rotational and translational corrections were implemented to account for imperfect phantom alignment. Measurements were made to assess uncertainties arising from susceptibility artifacts, image noise, and phantom construction accuracy. For a clinical 3D imaging protocol with a 1.5 mm reconstructed slice thickness, 100% of spheres within a 50 mm radius of isocenter had a 3D deviation of 1 mm or less. Of the spheres within 100 mm of isocenter, 99.9% had a 3D deviation less than 1 mm. 94.8% and 100% of the spheres within 175 mm were found to be within 1 mm and 2 mm of the expected positions in 3D respectively. Maximum 3D distortions within 50 mm, 100 mm and 175 mm of isocenter were 0.76 mm, 1.15 mm and 1.88 mm respectively. Distortions present in images acquired using the real-time imaging sequence were less than 1 mm for 98.1% and 95.0% of the cylinders within 50 mm and 100 mm of isocenter. The corresponding maximum distortion in these regions was 1.10 mm and 1.67 mm. These results may be used to inform appropriate planning target volume (PTV) margins for 0.35 T MRI-guided radiotherapy. Observed levels of spatial distortion should be explicitly considered when using PTV margins of 3 mm or less or in the case of targets displaced from isocenter by more than 50 mm.

  8. Hydrologic cost-effectiveness ratio favors switchgrass production on marginal croplands over existing grasslands

    PubMed Central

    Yimam, Yohannes Tadesse; Ochsner, Tyson E.; Fox, Garey A.

    2017-01-01

    Switchgrass (Panicum virgatum L.) has attracted attention as a promising second generation biofuel feedstock. Both existing grasslands and marginal croplands have been suggested as targets for conversion to switchgrass, but the resulting production potentials and hydrologic impacts are not clear. The objectives of this study were to model switchgrass production on existing grasslands (scenario-I) and on marginal croplands that have severe to very severe limitations for crop production (scenario-II) and to evaluate the effects on evapotranspiration (ET) and streamflow. The Soil and Water Assessment Tool (SWAT) was applied to the 1063 km2 Skeleton Creek watershed in north-central Oklahoma, a watershed dominated by grasslands (35%) and winter wheat cropland (47%). The simulated average annual yield (2002–2011) for rainfed Alamo switchgrass for both scenarios was 12 Mg ha-1. Yield varied spatially under scenario-I from 6.1 to 15.3 Mg ha-1, while under scenario-II the range was from 8.2 to 13.8 Mg ha-1. Comparison of average annual ET and streamflow between the baseline simulation (existing land use) and scenario-I showed that scenario-I had 5.6% (37 mm) higher average annual ET and 27.7% lower streamflow, representing a 40.7 million m3 yr-1 streamflow reduction. Compared to the baseline, scenario-II had only 0.5% higher ET and 3.2% lower streamflow, but some monthly impacts were larger. In this watershed, the water yield reduction per ton of biomass production (i.e. hydrologic cost-effectiveness ratio) was more than 5X greater under scenario-I than under scenario-II. These results suggest that, from a hydrologic perspective, it may be preferable to convert marginal cropland to switchgrass production rather than converting existing grasslands. PMID:28792541

  9. Family Caregiver Marginalization is Associated with Decreased Primary and Subspecialty Asthma Care in Head Start Children.

    PubMed

    Sadreameli, S Christy; Riekert, Kristin A; Matsui, Elizabeth C; Rand, Cynthia S; Eakin, Michelle N

    2018-05-03

    Urban minority children are at risk for poor asthma outcomes and may not receive appropriate primary or subspecialty care. We hypothesized that preschool children with asthma whose caregivers reported more barriers to care would be less likely to have seen their primary care provider (PCP) or an asthma subspecialist and more likely to have had a recent emergency department (ED) visit for asthma. The Barriers to Care Questionnaire (BCQ) measures expectations, knowledge, marginalization, pragmatics, and skills. We assessed asthma control via TRACK and these outcomes: PCP visits for asthma in past six months, subspecialty care (allergist or pulmonologist) in past two years, and ED visits in past three months. 395 caregivers (96% African-American, 82% low-income, 96% Medicaid) completed the BCQ. Sixty percent(N=236) of children had uncontrolled asthma, 86% had seen a PCP, 23% had seen a subspecialist, and 29% had an ED visit. Barriers related to marginalization were associated with decreased likelihood of PCP (OR 0.95, p=0.014) and subspecialty visits (OR 0.92, p=0.019). Overall BCQ score was associated with decreased likelihood of subspecialty care (OR 0.98, p=0.027). Barriers related to expectations, knowledge, pragmatics, and skills were not associated with any of the care outcomes. Among low-income, predominantly African-American preschool children with asthma, primary and subspecialty care were less likely if caregivers reported past negative experiences with the healthcare system (marginalization). Clinicians who serve at-risk populations should be sensitive to families' past experiences and should consider designing interventions to target the most commonly reported barriers. Copyright © 2018. Published by Elsevier Inc.

  10. Hydrologic cost-effectiveness ratio favors switchgrass production on marginal croplands over existing grasslands.

    PubMed

    Yimam, Yohannes Tadesse; Ochsner, Tyson E; Fox, Garey A

    2017-01-01

    Switchgrass (Panicum virgatum L.) has attracted attention as a promising second generation biofuel feedstock. Both existing grasslands and marginal croplands have been suggested as targets for conversion to switchgrass, but the resulting production potentials and hydrologic impacts are not clear. The objectives of this study were to model switchgrass production on existing grasslands (scenario-I) and on marginal croplands that have severe to very severe limitations for crop production (scenario-II) and to evaluate the effects on evapotranspiration (ET) and streamflow. The Soil and Water Assessment Tool (SWAT) was applied to the 1063 km2 Skeleton Creek watershed in north-central Oklahoma, a watershed dominated by grasslands (35%) and winter wheat cropland (47%). The simulated average annual yield (2002-2011) for rainfed Alamo switchgrass for both scenarios was 12 Mg ha-1. Yield varied spatially under scenario-I from 6.1 to 15.3 Mg ha-1, while under scenario-II the range was from 8.2 to 13.8 Mg ha-1. Comparison of average annual ET and streamflow between the baseline simulation (existing land use) and scenario-I showed that scenario-I had 5.6% (37 mm) higher average annual ET and 27.7% lower streamflow, representing a 40.7 million m3 yr-1 streamflow reduction. Compared to the baseline, scenario-II had only 0.5% higher ET and 3.2% lower streamflow, but some monthly impacts were larger. In this watershed, the water yield reduction per ton of biomass production (i.e. hydrologic cost-effectiveness ratio) was more than 5X greater under scenario-I than under scenario-II. These results suggest that, from a hydrologic perspective, it may be preferable to convert marginal cropland to switchgrass production rather than converting existing grasslands.

  11. Application of the WFD cost proportionality principle to diffuse pollution mitigation: a case study for Scottish Lochs.

    PubMed

    Vinten, A J A; Martin-Ortega, J; Glenk, K; Booth, P; Balana, B B; MacLeod, M; Lago, M; Moran, D; Jones, M

    2012-04-30

    The Water Framework Directive (WFD) aims to deliver good ecological status (GES) for Europe's waters. It prescribes the use of economic principles, such as derogation from GES on grounds of disproportionate costs of mitigation. This paper proposes an application of the proportionality principle to mitigation of phosphorus (P) pollution of 544 Scottish lochs at national and local water body scales. P loading estimates were derived from a national diffuse pollution screening tool. For 293 of these lochs (31% of the loch area), GES already occurred. Mitigation cost-effectiveness was assessed using combined mitigation cost curves for managed grassland, rough grazing, arable land, sewage and septic tank sources. These provided sufficient mitigation (92% of national P load) for GES to be achieved on another 31% of loch area at annualised cost of £2.09 m/y. Mitigation of the residual P loading preventing other lochs achieving GES was considered by using a "mop-up" cost of £200/kg P (assumed cost effectiveness of removal of P directly from lochs), leading to a total cost of £189 m/y. Lochs were ranked by mitigation costs per loch area to give a national scale marginal mitigation cost curve. A published choice experiment valuation of WFD targets for Scottish lochs was used to estimate marginal benefits at national scale and combined with the marginal cost curve. This gave proportionate costs of £5.7 m/y leading to GES in 72% of loch area. Using national mean marginal benefits with a scheme to estimate changes in individual loch value with P loading gave proportionate costs of £25.6 m/y leading to GES in 77% of loch area (491 lochs). Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balderson, Michael, E-mail: michael.balderson@rmp.uhn.ca; Brown, Derek; Johnson, Patricia

    The purpose of this work was to compare static gantry intensity-modulated radiation therapy (IMRT) with volume-modulated arc therapy (VMAT) in terms of tumor control probability (TCP) under scenarios involving large geometric misses, i.e., those beyond what are accounted for when margin expansion is determined. Using a planning approach typical for these treatments, a linear-quadratic–based model for TCP was used to compare mean TCP values for a population of patients who experiences a geometric miss (i.e., systematic and random shifts of the clinical target volume within the planning target dose distribution). A Monte Carlo approach was used to account for themore » different biological sensitivities of a population of patients. Interestingly, for errors consisting of coplanar systematic target volume offsets and three-dimensional random offsets, static gantry IMRT appears to offer an advantage over VMAT in that larger shift errors are tolerated for the same mean TCP. For example, under the conditions simulated, erroneous systematic shifts of 15 mm directly between or directly into static gantry IMRT fields result in mean TCP values between 96% and 98%, whereas the same errors on VMAT plans result in mean TCP values between 45% and 74%. Random geometric shifts of the target volume were characterized using normal distributions in each Cartesian dimension. When the standard deviations were doubled from those values assumed in the derivation of the treatment margins, our model showed a 7% drop in mean TCP for the static gantry IMRT plans but a 20% drop in TCP for the VMAT plans. Although adding a margin for error to a clinical target volume is perhaps the best approach to account for expected geometric misses, this work suggests that static gantry IMRT may offer a treatment that is more tolerant to geometric miss errors than VMAT.« less

  13. Treatment plan comparison between Tri-Co-60 magnetic-resonance image-guided radiation therapy and volumetric modulated arc therapy for prostate cancer

    PubMed Central

    Park, Jong Min; Park, So-Yeon; Choi, Chang Heon; Chun, Minsoo; Kim, Jin Ho; Kim, Jung-In

    2017-01-01

    To investigate the plan quality of tri-Co-60 intensity-modulated radiation therapy (IMRT) with magnetic-resonance image-guided radiation therapy compared with volumetric-modulated arc therapy (VMAT) for prostate cancer. Twenty patients with intermediate-risk prostate cancer, who received radical VMAT were selected. Additional tri-Co-60 IMRT plans were generated for each patient. Both primary and boost plans were generated with tri-Co-60 IMRT and VMAT techniques. The prescription doses of the primary and boost plans were 50.4 Gy and 30.6 Gy, respectively. The primary and boost planning target volumes (PTVs) of the tri-Co-60 IMRT were generated with 3 mm margins from the primary clinical target volume (CTV, prostate + seminal vesicle) and a boost CTV (prostate), respectively. VMAT had a primary planning target volume (primary CTV + 1 cm or 2 cm margins) and a boost PTV (boost CTV + 0.7 cm margins), respectively. For both tri-Co-60 IMRT and VMAT, all the primary and boost plans were generated that 95% of the target volumes would be covered by the 100% of the prescription doses. Sum plans were generated by summation of primary and boost plans. In sum plans, the average values of V70 Gy of the bladder of tri-Co-60 IMRT vs. VMAT were 4.0% ± 3.1% vs. 10.9% ± 6.7%, (p < 0.001). Average values of V70 Gy of the rectum of tri-Co-60 IMRT vs. VMAT were 5.2% ± 1.8% vs. 19.1% ± 4.0% (p < 0.001). The doses of tri-Co-60 IMRT delivered to the bladder and rectum were smaller than those of VMAT while maintaining identical target coverage in both plans. PMID:29207634

  14. Simulation of intrafraction motion and overall geometric accuracy of a frameless intracranial radiosurgery process

    PubMed Central

    Walker, Luke; Chinnaiyan, Prakash; Forster, Kenneth

    2008-01-01

    We conducted a comprehensive evaluation of the clinical accuracy of an image‐guided frameless intracranial radiosurgery system. All links in the process chain were tested. Using healthy volunteers, we evaluated a novel method to prospectively quantify the range of target motion for optimal determination of the planning target volume (PTV) margin. The overall system isocentric accuracy was tested using a rigid anthropomorphic phantom containing a hidden target. Intrafraction motion was simulated in 5 healthy volunteers. Reinforced head‐and‐shoulders thermoplastic masks were used for immobilization. The subjects were placed in a treatment position for 15 minutes (the maximum expected time between repeated isocenter localizations) and the six‐degrees‐of‐freedom target displacements were recorded with high frequency by tracking infrared markers. The markers were placed on a customized piece of thermoplastic secured to the head independently of the immobilization mask. Additional data were collected with the subjects holding their breath, talking, and deliberately moving. As compared with fiducial matching, the automatic registration algorithm did not introduce clinically significant errors (<0.3 mm difference). The hidden target test confirmed overall system isocentric accuracy of ≤1 mm (total three‐dimensional displacement). The subjects exhibited various patterns and ranges of head motion during the mock treatment. The total displacement vector encompassing 95% of the positional points varied from 0.4 mm to 2.9 mm. Pre‐planning motion simulation with optical tracking was tested on volunteers and appears promising for determination of patient‐specific PTV margins. Further patient study is necessary and is planned. In the meantime, system accuracy is sufficient for confident clinical use with 3 mm PTV margins. PACS number: 87.53.Ly

  15. [Oxidative stress experimental model of rat with stria vascularis marginal cells injury induced by hydrogen peroxide in vitro].

    PubMed

    Li, Jun; Kong, Wei-jia; Zhao, Xue-yan; Hu, Yu-juan

    2008-11-01

    To set up the oxidative stress experimental model of rat cochlea with stria vascularis marginal cells injury induced by hydrogen peroxide in vitro. Cultured marginal cells of rat were treated by 200, 300, 400, 600 and 800 micromol/L hydrogen peroxide (H(2)O(2)) for 0.5, 1, 2, 4, 16 and 24 hours, respectively. Cell viability was assessed by the CCK-8 assay. The content of the lipid peroxidation production malondialdehyde (MDA) were detected in H(2)O(2) induced marginal cells injury with different concentration H(2)O(2). Apoptosis was assessed by flow cytometry by propidium sodium staining. The expression of the cleaved-caspase-3 was assessed by Western blot. Being exposed to H(2)O(2), marginal cells displayed nuclear pyknosis and margination, cytoplasmic condensation, cell shrinkage and formation of membrane and bounded apoptotic bodies. A time-dependent and dose-dependent decrease of cellular viability was detected with the treatment of H(2)O(2). Cellular maleic dialdehyde was generated in proportion to the concentration of H(2)O(2) at 2 hours and the number of apoptotic cells increased significantly (P < 0. 05). Western blot showed the expression of the cleaved-caspase-3 increased when 200 micromol/L, 300 micromol/L and 400 micromol/L H(2)O(2) treated cultured marginal cells. Thereafter the expression of the cleaved-caspase-3 decreased with 600 micromol/L H(2)O(2) and with 800 micromol/L H(2)O(2) the expression of cleaved-caspase-3 was weak. The findings indicated that the experimental model can be established successfully using cultured cells exposed to H(2)O(2) and activation of caspase-3 is associated with hydrogen peroxide induced rat marginal cells the oxidative stress injury.

  16. Assessing Mediation Using Marginal Structural Models in the Presence of Confounding and Moderation

    ERIC Educational Resources Information Center

    Coffman, Donna L.; Zhong, Wei

    2012-01-01

    This article presents marginal structural models with inverse propensity weighting (IPW) for assessing mediation. Generally, individuals are not randomly assigned to levels of the mediator. Therefore, confounders of the mediator and outcome may exist that limit causal inferences, a goal of mediation analysis. Either regression adjustment or IPW…

  17. Free-breathing conformal irradiation of pancreatic cancer.

    PubMed

    Solla, Ignazio; Zucca, Sergio; Possanzini, Marco; Piras, Sara; Pusceddu, Claudio; Porru, Sergio; Meleddu, Gianfranco; Farace, Paolo

    2013-07-08

    The purpose of this study was to assess treatment margins in free-breathing irradiation of pancreatic cancer after bone alignment, and evaluate their impact on conformal radiotherapy. Fifteen patients with adenocarcinoma of the head of the pancreas underwent implantation of single fiducial marker. Intrafraction uncertainties were assessed on simulation four-dimensional computed tomography (4D CT) by calculating maximal intrafraction fiducial excursion (MIFE). In the first ten patients, after bony alignment, the position of the fiducial was identified on weekly acquired megavolt cone-beam CT (MV-CBCT). The interfraction residual uncertainties were estimated by measuring the fiducial displacements with respect to the position in the first session. Patient mean (pM) and patient standard deviation (pSD) of fiducial displacement, mean (μM) and standard deviation (μSD) of pM, and root-mean-square of pSD (σ(res)) were calculated. In the other five patients, MIFE was added to the residual component to obtain personalized margin. In these patients, conformal kidney sparing (CONKISS) irradiation was planned prescribing 54/45 Gy to PTV1/PTV2. The organ-at-risk limits were set according to current NCCN recommendation. No morbidity related to the fiducial marker implantation was recorded. In the first ten patients, along right-left, anterior-posterior, and inferior-superior directions, MIFE was variable (mean ± std = 0.24 ± 0.13 cm, 0.31 ± 0.14 cm, 0.83 ± 0.35 cm, respectively) and was at most 0.51, 0.53, and 1.56 cm, respectively. Along the same directions, μM were 0.09, -0.05, -0.05 cm, μSD were 0.30, 0.17, 0.33 cm, and σ(res) were 0.35, 0.26, and 0.30 cm, respectively. MIFE was not correlated with pM and pSD. In the five additional patients, it was possible to satisfy recommended dose limits, with the exception of slightly higher doses to small bowel. After bony alignment, the margins for target expansion can be obtained by adding personalized MIFE to the residual interfraction term. Using these margins, conformal free-breathing irradiation is a reliable option for the treatment of pancreatic cancer.

  18. Free‐breathing conformal irradiation of pancreatic cancer

    PubMed Central

    Solla, Ignazio; Zucca, Sergio; Possanzini, Marco; Piras, Sara; Pusceddu, Claudio; Porru, Sergio; Meleddu, Gianfranco

    2013-01-01

    The purpose of this study was to assess treatment margins in free‐breathing irradiation of pancreatic cancer after bone alignment, and evaluate their impact on conformal radiotherapy. Fifteen patients with adenocarcinoma of the head of the pancreas underwent implantation of single fiducial marker. Intrafraction uncertainties were assessed on simulation four‐dimensional computed tomography (4D CT) by calculating maximal intrafraction fiducial excursion (MIFE). In the first ten patients, after bony alignment, the position of the fiducial was identified on weekly acquired megavolt cone‐beam CT (MV‐CBCT). The interfraction residual uncertainties were estimated by measuring the fiducial displacements with respect to the position in the first session. Patient mean (pM) and patient standard deviation (pSD) of fiducial displacement, mean (μM) and standard deviation (μSD) of pM, and root‐mean‐square of pSD (σres) were calculated. In the other five patients, MIFE was added to the residual component to obtain personalized margin. In these patients, conformal kidney sparing (CONKISS) irradiation was planned prescribing 54/45 Gy to PTV1/PTV2. The organ‐at‐risk limits were set according to current NCCN recommendation. No morbidity related to the fiducial marker implantation was recorded. In the first ten patients, along right–left, anterior–posterior, and inferior–superior directions, MIFE was variable (mean±std=0.24±0.13cm,0.31±0.14cm,0.83±0.35cm, respectively) and was at most 0.51, 0.53, and 1.56 cm, respectively. Along the same directions, μM were 0.09,−0.05,−0.05cm,μSD were 0.30, 0.17, 0.33 cm, and σres were 0.35, 0.26, and 0.30 cm, respectively. MIFE was not correlated with pM and pSD. In the five additional patients, it was possible to satisfy recommended dose limits, with the exception of slightly higher doses to small bowel. After bony alignment, the margins for target expansion can be obtained by adding personalized MIFE to the residual interfraction term. Using these margins, conformal free‐breathing irradiation is a reliable option for the treatment of pancreatic cancer. PACS number: 87.55.D‐ PMID:23835380

  19. Optimal Patient Positioning (Prone Versus Supine) for VMAT in Gynecologic Cancer: A Dosimetric Study on the Effect of Different Margins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heijkoop, Sabrina T., E-mail: s.heijkoop@erasmusmc.nl; Westerveld, Henrike; Bijker, Nina

    Purpose/Objective: It is unknown whether the historically found dosimetric advantages of treating gynecologic cancer with the patient in a prone position with use of a small-bowel displacement device (belly-board) remain when volumetric arc therapy (VMAT) is used and whether these advantages depend on the necessary margin between clinical target volume (CTV) and planning target volume (PTV). The aim of this study is to determine the best patient position (prone or supine) in terms of sparing organs at risk (OAR) for various CTV-to-PTV margins and VMAT dose delivery. Methods and Materials: In an institutional review board—approved study, 26 patients with gynecologicmore » cancer scheduled for primary (9) or postoperative (17) radiation therapy were scanned in a prone position on a belly-board and in a supine position on the same day. The primary tumor CTV, nodal CTV, bladder, bowel, and rectum were delineated on both scans. The PTVs were created each with a different margin for the primary tumor and nodal CTV. The VMAT plans were generated with our in-house system for automated treatment planning. For all margin combinations, the supine and prone plans were compared with consideration of all OAR dose-volume parameters but with highest priority given to bowel cavity V{sub 45Gy} (cm{sup 3}). Results: For both groups, the prone position reduced the bowel cavity V{sub 45Gy}, in particular for nodal margins ≥10 mm (ΔV{sub 45Gy} = 23.9 ± 10.6 cm{sup 3}). However, for smaller margins, the advantage was much less pronounced (ΔV{sub 45Gy} = 6.5 ± 3.0 cm{sup 3}) and did not reach statistical significance. The rectum mean dose (D{sub mean}) was significantly lower (ΔD{sub mean} = 2.5 ± 0.3 Gy) in the prone position for both patient groups and for all margins, and the bladder D{sub mean} was significantly lower in the supine position (ΔD{sub mean} = 2.6 ± 0.4 Gy) only for the postoperative group. The advantage of the prone position was not present if it needed a larger margin than the supine position. Conclusion: For patients with gynecologic cancer, the historically found dosimetric advantages for the prone position remain for modern dose delivery techniques if large margins are needed. However, the advantage is lost for small margins and if the prone position needs a larger margin than the supine position.« less

  20. MRI Evaluation of Resection Margins in Bone Tumour Surgery

    PubMed Central

    Traore, Sidi Yaya; Lecouvet, Frédéric; Galant, Christine

    2014-01-01

    In 12 patients operated on for bone sarcoma resection, a postoperative magnetic resonance imaging of the resection specimens was obtained in order to assess the surgical margins. Margins were classified according to MRI in R0, R1, and R2 by three independent observers: a radiologist and two orthopaedic surgeons. Final margin evaluation (R0, R1, and R2) was assessed by a confirmed pathologist. Agreement for margin evaluation between the pathologist and the radiologist was perfect (κ = 1). Agreement between the pathologist and an experienced orthopaedic surgeon was very good while it was fair between the pathologist and a junior orthopaedic surgeon. MRI should be considered as a tool to give quick information about the adequacy of margins and to help the pathologist to focus on doubtful areas and to spare time in specimen analysis. But it may not replace the pathological evaluation that gives additional information about tumor necrosis. This study shows that MRI extemporaneous analysis of a resection specimen may be efficient in bone tumor oncologic surgery, if made by an experienced radiologist with perfect agreement with the pathologist. PMID:24976785

  1. Developing tools to identify marginal lands and assess their potential for bioenergy production

    NASA Astrophysics Data System (ADS)

    Galatsidas, Spyridon; Gounaris, Nikolaos; Dimitriadis, Elias; Rettenmaier, Nils; Schmidt, Tobias; Vlachaki, Despoina

    2017-04-01

    The term "marginal land" is currently intertwined in discussions about bioenergy although its definition is neither specific nor firm. The uncertainty arising from marginal land classification and quantification is one of the major constraining factors for its potential use. The clarification of political aims, i.e. "what should be supported?" is also an important constraining factor. Many approaches have been developed to identify marginal lands, based on various definitions according to the management goals. Concerns have been frequently raised regarding the impacts of marginal land use on environment, ecosystem services and sustainability. Current tools of soil quality and land potentials assessment fail to meet the needs of marginal land identification and exploitation for biomass production, due to the lack of comprehensive analysis of interrelated land functions and their quantitative evaluation. Land marginality is determined by dynamic characteristics in many cases and may therefore constitute a transitional state, which requires reassessment in due time. Also, marginal land should not be considered simply a dormant natural resource waiting to be used, since it may already provide multiple benefits and services to society relating to wildlife, biodiversity, carbon sequestration, etc. The consequences of cultivating such lands need to be fully addressed to present a balanced view of their sustainable potential for bioenergy. This framework is the basis for the development of the SEEMLA tools, which aim at supporting the identification, assessment, management of marginal lands in Europe and the decision-making for sustainable biomass production of them using appropriate bioenergy crops. The tools comprise two applications, a web-based one (independent of spatial data) and a GIS-based application (land regionalization on the basis of spatial data), which both incorporate: - Land resource characteristics, restricting the cultivation of agricultural crops but effectively sustaining bioenergy plants (soil, climate, topography, vegetation, etc.) - Bioenergy plant characteristics and their ability to grow on marginal lands - Needs and concerns on environmental issues and ecosystem benefits and services (biodiversity, carbon sequestration potential, soil organic carbon trend, etc.) - Sustainability assessments (incl. e.g. LCA) of biomass production at market scale - Analysis results of generic scenarios for biomass production, harvesting, logistics and conditioning, as well as biomass conversion and use from pilot cases growing various crops The SEEMLA approach of marginal lands evaluation will provide private and public stakeholders with necessary guidance for selecting suitable lands and implementing efficient exploitation strategies for bioenergy production, on the basis of sound environmental and socio-economic criteria.

  2. Intraoperative Molecular Imaging of Lung Adenocarcinoma Can Identify Residual Tumor Cells at the Surgical Margins

    PubMed Central

    Keating, Jane J.; Okusanya, Olugbenga T.; De Jesus, Elizabeth; Judy, Ryan; Jiang, Jack; Deshpande, Charuhas; Nie, Shuming; Low, Philip; Singhal, Sunil

    2017-01-01

    Purpose During lung surgery, identification of surgical margins is challenging. We hypothesized that molecular imaging with a fluorescent probe to pulmonary adenocarcinomas could enhance residual tumor during resection. Procedures Mice with flank tumors received a contrast agent targeting folate receptor alpha. Optimal dose and time of injection was established. Margin detection was compared using traditional methods versus molecular imaging. A pilot study was then performed in 3 humans with lung adenocarcinoma. Results The peak tumor-to background ratio (TBR) of murine tumors was 3.9. Fluorescence peaked at 2 hours and was not improved beyond 0.1 mg/kg. Traditional inspection identified 30% of mice with positive margins. Molecular imaging identified an additional 50% of residual tumor deposits (P<0.05). The fluorescent probe visually enhanced all human tumors with a mean TBR of 3.5. Conclusions Molecular imaging is an important adjunct to traditional inspection to identify surgical margins after tumor resection. PMID:26228697

  3. Intensity-modulated radiotherapy (IMRT) in pediatric low-grade glioma.

    PubMed

    Paulino, Arnold C; Mazloom, Ali; Terashima, Keita; Su, Jack; Adesina, Adekunle M; Okcu, M Faith; Teh, Bin S; Chintagumpala, Murali

    2013-07-15

    The objective of this study was to evaluate local control and patterns of failure in pediatric patients with low-grade glioma (LGG) who received treatment with intensity-modulated radiation therapy (IMRT). In total, 39 children received IMRT after incomplete resection or disease progression. Three methods of target delineation were used. The first was to delineate the gross tumor volume (GTV) and add a 1-cm margin to create the clinical target volume (CTV) (Method 1; n = 19). The second was to add a 0.5-cm margin around the GTV to create the CTV (Method 2; n = 6). The prescribed dose to the GTV was the same as dose to the CTV for both Methods 1 and 2 (median, 50.4 grays [Gy]). The final method was dose painting, in which a GTV was delineated with a second target volume (2TV) created by adding 1 cm to the GTV (Method 3; n = 14). Different doses were prescribed to the GTV (median, 50.4 Gy) and the 2TV (median, 41.4 Gy). The 8-year progression-free and overall survival rates were 78.2% and 93.7%, respectively. Seven failures occurred, all of which were local in the high-dose (≥95%) region of the IMRT field. On multivariate analysis, age ≤5 years at time of IMRT had a detrimental impact on progression-free survival. IMRT provided local control rates comparable to those provided by 2-dimensional and 3-dimensional radiotherapy. Margins ≥1 cm added to the GTV may not be necessary, because excellent local control was achieved by adding a 0.5-cm margin (Method 2) and by dose painting (Method 3). © 2013 American Cancer Society.

  4. Fractionated stereotactic radiotherapy boost for gynecologic tumors: An alternative to brachytherapy?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Molla, Meritxell; Escude, Lluis D.; Nouet, Philippe

    2005-05-01

    Purpose: A brachytherapy (BT) boost to the vaginal vault is considered standard treatment for many endometrial or cervical cancers. We aimed to challenge this treatment standard by using stereotactic radiotherapy (SRT) with a linac-based micromultileaf collimator technique. Methods and Materials: Since January 2002, 16 patients with either endometrial (9) or cervical (7) cancer have been treated with a final boost to the areas at higher risk for relapse. In 14 patients, the target volume included the vaginal vault, the upper vagina, the parametria, or (if not operated) the uterus (clinical target volume [CTV]). In 2 patients with local relapse, themore » CTV was the tumor in the vaginal stump. Margins of 6-10 mm were added to the CTV to define the planning target volume (PTV). Hypofractionated dynamic-arc or intensity-modulated radiotherapy techniques were used. Postoperative treatment was delivered in 12 patients (2 x 7 Gy to the PTV with a 4-7-day interval between fractions). In the 4 nonoperated patients, a dose of 4 Gy/fraction in 5 fractions with 2 to 3 days' interval was delivered. Patients were immobilized in a customized vacuum body cast and optimally repositioned with an infrared-guided system developed for extracranial SRT. To further optimize daily repositioning and target immobilization, an inflated rectal balloon was used during each treatment fraction. In 10 patients, CT resimulation was performed before the last boost fraction to assess for repositioning reproducibility via CT-to-CT registration and to estimate PTV safety margins around the CTV. Finally, a comparative treatment planning study between BT and SRT was performed in 2 patients with an operated endometrial Stage I cancer. Results: No patient developed severe acute urinary or low-intestinal toxicity. No patient developed urinary late effects (>6 months). One patient with a vaginal relapse previously irradiated to the pelvic region presented with Grade 3 rectal bleeding 18 months after retreatment. A second patient known to suffer from irritable bowel syndrome presented with Grade 1 abdominal pain after treatment. The estimated PTV margins around the CTV were 9-10 mm with infrared marker registration. External SRT succeeded in improving dose homogeneity to the PTV and in reducing the maximum dose to the rectum, when compared to BT. Conclusion: These results suggest that the use of external SRT to deliver a final boost to the areas at higher risk for relapse in endometrial or cervical cancer is feasible, well tolerated, and may well be considered an acceptable alternative to BT.« less

  5. The Relationship Between Hope and Adolescent Likelihood to Endorse Substance Use Behaviors in a Sample of Marginalized Youth.

    PubMed

    Brooks, Merrian J; Marshal, Michael P; McCauley, Heather L; Douaihy, Antoine; Miller, Elizabeth

    2016-11-09

    Hopefulness has been associated with increased treatment retention and reduced substance abuse among adults, and may be a promising modifiable factor to leverage in substance abuse treatment settings. Few studies have assessed the relationship between hopefulness and substance use in adolescents, particularly those with high-risk backgrounds. We explored whether high hope is associated with less likelihood for engaging in a variety of substance use behaviors in a sample of marginalized adolescents. Using logistic regression, we assessed results from a cross-sectional anonymous youth behavior survey (n = 256 youth, ages 14 to 19). We recruited from local youth serving agencies (e.g., homeless shelters, group homes, short-term detention). The sample was almost 60% male and two thirds African American. Unadjusted models showed youth with higher hope had a 50-58% (p = <.05) decreased odds of endorsing heavy episodic drinking, daily tobacco use, recent or lifetime marijuana use, and sex after using substances. Adjusted models showed a 52% decreased odds of lifetime marijuana use with higher hope, and a trend towards less sex after substance use (AOR 0.481; p = 0.065). No other substance use behaviors remained significantly associated with higher hope scores in adjusted models. Hopefulness may contribute to decreased likelihood of substance use in adolescents. Focusing on hope may be one modifiable target in a comprehensive primary or secondary substance use prevention program.

  6. Circumferential resection margin (CRM) positivity after MRI assessment and adjuvant treatment in 189 patients undergoing rectal cancer resection.

    PubMed

    Simpson, G S; Eardley, N; McNicol, F; Healey, P; Hughes, M; Rooney, P S

    2014-05-01

    The management of rectal cancer relies on accurate MRI staging. Multi-modal treatments can downstage rectal cancer prior to surgery and may have an effect on MRI accuracy. We aim to correlate the findings of MRI staging of rectal cancer with histological analysis, the effect of neoadjuvant therapy on this and the implications of circumferential resection margin (CRM) positivity following neoadjuvant therapy. An analysis of histological data and radiological staging of all cases of rectal cancer in a single centre between 2006 and 2011 were conducted. Two hundred forty-one patients had histologically proved rectal cancer during the study period. One hundred eighty-two patients underwent resection. Median age was 66.6 years, and male to female ratio was 13:5. R1 resection rate was 11.1%. MRI assessments of the circumferential resection margin in patients without neoadjuvant radiotherapy were 93.6 and 88.1% in patients who underwent neoadjuvant radiotherapy. Eighteen patients had predicted positive margins following chemoradiotherapy, of which 38.9% had an involved CRM on histological analysis. MRI assessment of the circumferential resection margin in rectal cancer is associated with high accuracy. Neoadjuvant chemoradiotherapy has a detrimental effect on this accuracy, although accuracy remains high. In the presence of persistently predicted positive margins, complete resection remains achievable but may necessitate a more radical approach to resection.

  7. Targeting incentives to reduce habitat fragmentation

    Treesearch

    David Lewis; Andrew Plantinga; Junjie Wu

    2009-01-01

    This article develops a theoretical model to analyze the spatial targeting of incentives for the restoration of forested landscapes when wildlife habitat can be enhanced by reducing fragmentation. The key theoretical result is that the marginal net benefits of increasing forest can be convex, in which case corner solutions--converting either none or all of the...

  8. Real-time auto-adaptive margin generation for MLC-tracked radiotherapy

    NASA Astrophysics Data System (ADS)

    Glitzner, M.; Fast, M. F.; de Senneville, B. Denis; Nill, S.; Oelfke, U.; Lagendijk, J. J. W.; Raaymakers, B. W.; Crijns, S. P. M.

    2017-01-01

    In radiotherapy, abdominal and thoracic sites are candidates for performing motion tracking. With real-time control it is possible to adjust the multileaf collimator (MLC) position to the target position. However, positions are not perfectly matched and position errors arise from system delays and complicated response of the electromechanic MLC system. Although, it is possible to compensate parts of these errors by using predictors, residual errors remain and need to be compensated to retain target coverage. This work presents a method to statistically describe tracking errors and to automatically derive a patient-specific, per-segment margin to compensate the arising underdosage on-line, i.e. during plan delivery. The statistics of the geometric error between intended and actual machine position are derived using kernel density estimators. Subsequently a margin is calculated on-line according to a selected coverage parameter, which determines the amount of accepted underdosage. The margin is then applied onto the actual segment to accommodate the positioning errors in the enlarged segment. The proof-of-concept was tested in an on-line tracking experiment and showed the ability to recover underdosages for two test cases, increasing {{V}90 %} in the underdosed area about 47 % and 41 % , respectively. The used dose model was able to predict the loss of dose due to tracking errors and could be used to infer the necessary margins. The implementation had a running time of 23 ms which is compatible with real-time requirements of MLC tracking systems. The auto-adaptivity to machine and patient characteristics makes the technique a generic yet intuitive candidate to avoid underdosages due to MLC tracking errors.

  9. Identification of Patients Expected to Benefit from Electronic Alerts for Acute Kidney Injury.

    PubMed

    Biswas, Aditya; Parikh, Chirag R; Feldman, Harold I; Garg, Amit X; Latham, Stephen; Lin, Haiqun; Palevsky, Paul M; Ugwuowo, Ugochukwu; Wilson, F Perry

    2018-06-07

    Electronic alerts for heterogenous conditions such as AKI may not provide benefit for all eligible patients and can lead to alert fatigue, suggesting that personalized alert targeting may be useful. Uplift-based alert targeting may be superior to purely prognostic-targeting of interventions because uplift models assess marginal treatment effect rather than likelihood of outcome. This is a secondary analysis of a clinical trial of 2278 adult patients with AKI randomized to an automated, electronic alert system versus usual care. We used three uplift algorithms and one purely prognostic algorithm, trained in 70% of the data, and evaluated the effect of targeting alerts to patients with higher scores in the held-out 30% of the data. The performance of the targeting strategy was assessed as the interaction between the model prediction of likelihood to benefit from alerts and randomization status. The outcome of interest was maximum relative change in creatinine from the time of randomization to 3 days after randomization. The three uplift score algorithms all gave rise to a significant interaction term, suggesting that a strategy of targeting individuals with higher uplift scores would lead to a beneficial effect of AKI alerting, in contrast to the null effect seen in the overall study. The prognostic model did not successfully stratify patients with regards to benefit of the intervention. Among individuals in the high uplift group, alerting was associated with a median reduction in change in creatinine of -5.3% ( P =0.03). In the low uplift group, alerting was associated with a median increase in change in creatinine of +5.3% ( P =0.005). Older individuals, women, and those with a lower randomization creatinine were more likely to receive high uplift scores, suggesting that alerts may benefit those with more slowly developing AKI. Uplift modeling, which accounts for treatment effect, can successfully target electronic alerts for AKI to those most likely to benefit, whereas purely prognostic targeting cannot. Copyright © 2018 by the American Society of Nephrology.

  10. Ultrasound-ultrasound image overlay fusion improves real-time control of radiofrequency ablation margin in the treatment of hepatocellular carcinoma.

    PubMed

    Minami, Yasunori; Minami, Tomohiro; Hagiwara, Satoru; Ida, Hiroshi; Ueshima, Kazuomi; Nishida, Naoshi; Murakami, Takamichi; Kudo, Masatoshi

    2018-05-01

    To assess the clinical feasibility of US-US image overlay fusion with evaluation of the ablative margin in radiofrequency ablation (RFA) for hepatocellular carcinoma (HCC). Fifty-three patients with 68 HCCs measuring 0.9-4.0 cm who underwent RFA guided by US-US overlay image fusion were included in this retrospective study. By an overlay of pre-/postoperative US, the tumor image could be projected onto the ablative hyperechoic zone. Therefore, the ablative margin three-dimensionally could be shown during the RFA procedure. US-US image overlay was compared to dynamic CT a few days after RFA for assessment of early treatment response. Accuracy of graded response was calculated, and the performance of US-US image overlay fusion was compared with that of CT using a Kappa agreement test. Technically effective ablation was achieved in a single session, and 59 HCCs (86.8 %) succeeded in obtaining a 5-mm margin on CT. The response with US-US image overlay correctly predicted early CT evaluation with an accuracy of 92.6 % (63/68) (k = 0.67; 95 % CI: 0.39-0.95). US-US image overlay fusion can be proposed as a feasible guidance in RFA with a safety margin and predicts early response of treatment assessment with high accuracy. • US-US image overlay fusion visualizes the ablative margin during RFA procedure. • Visualizing the margin during the procedure can prompt immediate complementary treatment. • US image fusion correlates with the results of early evaluation CT.

  11. A Pareto analysis approach to assess relevant marginal CO{sub 2} footprint for petroleum products

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tehrani, Nejad M. Alireza, E-mail: alireza.tehraninejad@gmail.com

    2015-07-15

    Recently, linear programing (LP) models have been extended to track the marginal CO{sub 2} intensity of automotive fuels at the refinery gate. The obtained CO{sub 2} data are recommended for policy making because they capture the economic and environmental tensions as well as the processing effects related to oil products. However, they are proven to be extremely sensitive to small perturbations and therefore useless in practice. In this paper, we first investigate the theoretical reasons of this drawback. Then, we develop a multiple objective LP framework to assess relevant marginal CO{sub 2} footprints that preserve both defensibility and stability atmore » a satisfactory level of acceptance. A case study illustrates this new methodology. - Highlights: • Refining LP models have limitations to provide useful marginal CO{sub 2} footprints. • A multi objective optimization framework is developed to assess relevant CO{sub 2} data. • Within a European Refinig industry, diesel is more CO{sub 2} intensive than gasoline.« less

  12. Induction and separation of motion artifacts in EEG data using a mobile phantom head device.

    PubMed

    Oliveira, Anderson S; Schlink, Bryan R; Hairston, W David; König, Peter; Ferris, Daniel P

    2016-06-01

    Electroencephalography (EEG) can assess brain activity during whole-body motion in humans but head motion can induce artifacts that obfuscate electrocortical signals. Definitive solutions for removing motion artifact from EEG have yet to be found, so creating methods to assess signal processing routines for removing motion artifact are needed. We present a novel method for investigating the influence of head motion on EEG recordings as well as for assessing the efficacy of signal processing approaches intended to remove motion artifact. We used a phantom head device to mimic electrical properties of the human head with three controlled dipolar sources of electrical activity embedded in the phantom. We induced sinusoidal vertical motions on the phantom head using a custom-built platform and recorded EEG signals with three different acquisition systems while the head was both stationary and in varied motion conditions. Recordings showed up to 80% reductions in signal-to-noise ratio (SNR) and up to 3600% increases in the power spectrum as a function of motion amplitude and frequency. Independent component analysis (ICA) successfully isolated the three dipolar sources across all conditions and systems. There was a high correlation (r > 0.85) and marginal increase in the independent components' (ICs) power spectrum (∼15%) when comparing stationary and motion parameters. The SNR of the IC activation was 400%-700% higher in comparison to the channel data SNR, attenuating the effects of motion on SNR. Our results suggest that the phantom head and motion platform can be used to assess motion artifact removal algorithms and compare different EEG systems for motion artifact sensitivity. In addition, ICA is effective in isolating target electrocortical events and marginally improving SNR in relation to stationary recordings.

  13. Induction and separation of motion artifacts in EEG data using a mobile phantom head device

    NASA Astrophysics Data System (ADS)

    Oliveira, Anderson S.; Schlink, Bryan R.; Hairston, W. David; König, Peter; Ferris, Daniel P.

    2016-06-01

    Objective. Electroencephalography (EEG) can assess brain activity during whole-body motion in humans but head motion can induce artifacts that obfuscate electrocortical signals. Definitive solutions for removing motion artifact from EEG have yet to be found, so creating methods to assess signal processing routines for removing motion artifact are needed. We present a novel method for investigating the influence of head motion on EEG recordings as well as for assessing the efficacy of signal processing approaches intended to remove motion artifact. Approach. We used a phantom head device to mimic electrical properties of the human head with three controlled dipolar sources of electrical activity embedded in the phantom. We induced sinusoidal vertical motions on the phantom head using a custom-built platform and recorded EEG signals with three different acquisition systems while the head was both stationary and in varied motion conditions. Main results. Recordings showed up to 80% reductions in signal-to-noise ratio (SNR) and up to 3600% increases in the power spectrum as a function of motion amplitude and frequency. Independent component analysis (ICA) successfully isolated the three dipolar sources across all conditions and systems. There was a high correlation (r > 0.85) and marginal increase in the independent components’ (ICs) power spectrum (˜15%) when comparing stationary and motion parameters. The SNR of the IC activation was 400%-700% higher in comparison to the channel data SNR, attenuating the effects of motion on SNR. Significance. Our results suggest that the phantom head and motion platform can be used to assess motion artifact removal algorithms and compare different EEG systems for motion artifact sensitivity. In addition, ICA is effective in isolating target electrocortical events and marginally improving SNR in relation to stationary recordings.

  14. Biomonitoring Data for 2,4-Dichlorophenoxyacetic Acid in the United States and Canada: Interpretation in a Public Health Risk Assessment Context Using Biomonitoring Equivalents

    PubMed Central

    Aylward, Lesa L.; Morgan, Marsha K.; Arbuckle, Tye E.; Barr, Dana B.; Burns, Carol J.; Alexander, Bruce H.; Hays, Sean M.

    2010-01-01

    Background Several extensive studies of exposure to 2,4-dichlorophenoxyacetic acid (2,4-D) using urinary concentrations in samples from the general population, farm applicators, and farm family members are now available. Reference doses (RfDs) exist for 2,4-D, and Biomonitoring Equivalents (BEs; concentrations in urine or plasma that are consistent with those RfDs) for 2,4-D have recently been derived and published. Objective We reviewed the available biomonitoring data for 2,4-D from the United States and Canada and compared them with BE values to draw conclusions regarding the margin of safety for 2,4-D exposures within each population group. Data sources Data on urinary 2,4-D excretion in general and target populations from recent published studies are tabulated and the derivation of BE values for 2,4-D summarized. Data synthesis The biomonitoring data indicate margins of safety (ratio of BE value to biomarker concentration) of approximately 200 at the central tendency and 50 at the extremes in the general population. Median exposures for applicators and their family members during periods of use appear to be well within acute exposure guidance values. Conclusions Biomonitoring data from these studies indicate that current exposures to 2,4-D are below applicable exposure guidance values. This review demonstrates the value of biomonitoring data in assessing population exposures in the context of existing risk assessments using the BE approach. Risk managers can use this approach to integrate the available biomonitoring data into an overall assessment of current risk management practices for 2,4-D. PMID:20123603

  15. Assessment of Clmate Change Mitigation Strategies for the Road Transport Sector of India

    NASA Astrophysics Data System (ADS)

    Singh, N.; Mishra, T.; Banerjee, R.

    2017-12-01

    India is one of the fastest growing major economies of the world. It imports three quarters of its oil demand, making transport sector major contributor of greenhouse gas (GHG) emissions. 40% of oil consumption in India comes from transport sector and over 90% of energy demand is from road transport sector. This has led to serious increase in CO2 emission and concentration of air pollutants in India. According to Intergovernmental Panel on Climate Change (IPCC), transport can play a crucial role for mitigation of global greenhouse gas emissions. Therefore, assessment of appropriate mitigation policies is required for emission reduction and cost benefit potential. The present study aims to estimate CO2, SO2, PM and NOx emissions from the road transport sector for the base year (2014) and target year (2030) by applying bottom up emission inventory model. Effectiveness of different mitigation strategies like inclusion of natural gas as alternate fuel, penetration of electric vehicle as alternate vehicle, improvement of fuel efficiency and increase share of public transport is evaluated for the target year. Emission reduction achieved from each mitigation strategies in the target year (2030) is compared with the business as usual scenario for the same year. To obtain cost benefit analysis, marginal abatement cost for each mitigation strategy is estimated. The study evaluates mitigation strategies not only on the basis of emission reduction potential but also on their cost saving potential.

  16. TH-CD-202-12: Online Inter-Beam Replanning Based On Real-Time Dose Reconstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kamerling, CP; Fast, MF; Ziegenhein, P

    Purpose: This work provides a proof-of-concept study for online replanning during treatment delivery for step-and-shoot prostate SBRT, based on real-time dose reconstruction. Online replanning is expected to improve the trade-off between target coverage and organ-at-risk dose in the presence of intra-fractional motion. Methods: We have implemented an online replanning workflow on top of our previously reported real-time dose reconstruction software which connects to an Elekta research linac. The treatment planning system DynaPlan was extended to (1) re-optimize and sequence treatment plans (in clockwise beam order) before each beam, based on actual delivered dose, in a timeframe limited by the gantrymore » rotation between subsequent beams, and (2) send the respective segments to the delivery control software DynaTrack which starts/continues treatment immediately.To investigate the impact of a reduced safety margin, we have created and delivered (on a linac emulator) a conventional CTV+5/3mm (I) and a reduced CTV+1mm margin (II) treatment plan for a prostate patient. We have assessed CTV coverage with and without inter-beam replanning, all exposed to a gradual target shift of 0–5mm in posterior and inferior direction from start until the end of delivery. Results: For the reconstructed conventional plan (I), D98 for CTV was 100% of D98 of the planned dose. For the reconstructed margin-reduced plan (II), D98 for CTV was 95% of the planned D98 without replanning, but could be recovered to 99% by replanning for each beam. Plan (II) with replanning resulted in a decrease for bladder V90% by 88% and an increase to rectum V90% by 9% compared to the conventional plan (I). Dose calculation/accumulation was performed in <15ms per MLC aperture, replanning in <15s per beam. Conclusion: We have shown that online inter-beam replanning is technically feasible and potentially allows for a margin reduction. Future investigation considering motion-robust replanning optimization parameters is in progress. We acknowledge support of the MLC research from Elekta AB. This work is supported by Cancer Research UK under Programme C33589/A19908. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR.« less

  17. Schedule for CT image guidance in treating prostate cancer with helical tomotherapy

    PubMed Central

    Beldjoudi, G; Yartsev, S; Bauman, G; Battista, J; Van Dyk, J

    2010-01-01

    The aim of this study was to determine the effect of reducing the number of image guidance sessions and patient-specific target margins on the dose distribution in the treatment of prostate cancer with helical tomotherapy. 20 patients with prostate cancer who were treated with helical tomotherapy using daily megavoltage CT (MVCT) imaging before treatment served as the study population. The average geometric shifts applied for set-up corrections, as a result of co-registration of MVCT and planning kilovoltage CT studies over an increasing number of image guidance sessions, were determined. Simulation of the consequences of various imaging scenarios on the dose distribution was performed for two patients with different patterns of interfraction changes in anatomy. Our analysis of the daily set-up correction shifts for 20 prostate cancer patients suggests that the use of four fractions would result in a population average shift that was within 1 mm of the average obtained from the data accumulated over all daily MVCT sessions. Simulation of a scenario in which imaging sessions are performed at a reduced frequency and the planning target volume margin is adapted provided significantly better sparing of organs at risk, with acceptable reproducibility of dose delivery to the clinical target volume. Our results indicate that four MVCT sessions on helical tomotherapy are sufficient to provide information for the creation of personalised target margins and the establishment of the new reference position that accounts for the systematic error. This simplified approach reduces overall treatment session time and decreases the imaging dose to the patient. PMID:19505966

  18. Safety margins in older adults increase with improved control of a dynamic object

    PubMed Central

    Hasson, Christopher J.; Sternad, Dagmar

    2014-01-01

    Older adults face decreasing motor capabilities due to pervasive neuromuscular degradations. As a consequence, errors in movement control increase. Thus, older individuals should maintain larger safety margins than younger adults. While this has been shown for object manipulation tasks, several reports on whole-body activities, such as posture and locomotion, demonstrate age-related reductions in safety margins. This is despite increased costs for control errors, such as a fall. We posit that this paradox could be explained by the dynamic challenge presented by the body or also an external object, and that age-related reductions in safety margins are in part due to a decreased ability to control dynamics. To test this conjecture we used a virtual ball-in-cup task that had challenging dynamics, yet afforded an explicit rendering of the physics and safety margin. The hypotheses were: (1) When manipulating an object with challenging dynamics, older adults have smaller safety margins than younger adults. (2) Older adults increase their safety margins with practice. Nine young and 10 healthy older adults practiced moving the virtual ball-in-cup to a target location in exactly 2 s. The accuracy and precision of the timing error quantified skill, and the ball energy relative to an escape threshold quantified the safety margin. Compared to the young adults, older adults had increased timing errors, greater variability, and decreased safety margins. With practice, both young and older adults improved their ability to control the object with decreased timing errors and variability, and increased their safety margins. These results suggest that safety margins are related to the ability to control dynamics, and may explain why in tasks with simple dynamics older adults use adequate safety margins, but in more complex tasks, safety margins may be inadequate. Further, the results indicate that task-specific training may improve safety margins in older adults. PMID:25071566

  19. Reinforcing marginality? Maternal health interventions in rural Nicaragua.

    PubMed

    Kvernflaten, Birgit

    2017-06-23

    To achieve Millennium Development Goal 5 on maternal health, many countries have focused on marginalized women who lack access to care. Promoting facility-based deliveries to ensure skilled birth attendance and emergency obstetric care has become a main measure for preventing maternal deaths, so women who opt for home births are often considered 'marginal' and in need of targeted intervention. Drawing upon ethnographic data from Nicaragua, this paper critically examines the concept of marginality in the context of official efforts to increase institutional delivery amongst the rural poor, and discusses lack of access to health services among women living in peripheral areas as a process of marginalization. The promotion of facility birth as the new norm, in turn, generates a process of 're-marginalization', whereby public health officials morally disapprove of women who give birth at home, viewing them as non-compliers and a problem to the system. In rural Nicaragua, there is a discrepancy between the public health norm and women's own preferences and desires for home birth. These women live at the margins also in spatial and societal terms, and must relate to a health system they find incapable of providing good, appropriate care. Strong public pressure for institutional delivery makes them feel distressed and pressured. Paradoxically then, the aim of including marginal groups in maternal health programmes engenders resistance to facility birth.

  20. Comparison of intensity-modulated radiotherapy and volumetric-modulated arc therapy dose measurement for head and neck cancer using optical stimulated luminescence dosimeter

    NASA Astrophysics Data System (ADS)

    Lai, Lu-Han; Chuang, Keh-Shih; Lin, Hsin-Hon; Liu, Yi-Chi; Kuo, Chiung-Wen; Lin, Jao-Perng

    2017-11-01

    The in-vivo dose distributions of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT), a newly developed technique, for head and neck cancer have been investigated for several years. The present study used a head-and-neck RANDO phantom to simulate the clinical conditions of nasopharyngeal carcinoma and compare the radiation doses between VMAT and IMRT. Three types of planning target volume (PTV) profiles were targeted by reducing the PTV surface margin by 0, 3, and 5 mm. An optically stimulated luminescence dosimeter was used to measure the surface doses. The results revealed that VMAT provided on average 16.8-13.8% lower surface doses within the PTV target areas than IMRT. When the PTV margin was reduced by 0 mm, the surface doses for IMRT reached their maximum value, accounting for 75.1% of its prescribed dose (Dp); however, the Dp value of VMAT was only 61.1%. When the PTV margin was reduced by 3 or 5 mm, the surface doses decreased considerably. The observed surface doses were insufficient when the tumours invaded the body surface; however, VMAT exerted larger skin-sparing effects than IMRT when the tumours away from the skin. These results suggest that the skin doses for these two techniques are insufficient for surface tumours. Notably, VMAT can provide lower skin doses for deep tumours.

  1. Biofuel development, food security and the use of marginal land in China.

    PubMed

    Qiu, Huanguang; Huang, Jikun; Keyzer, Michiel; van Veen, Wim; Rozelle, Scott; Fisher, Guenther; Ermolieva, Tatiana

    2011-01-01

    With concerns of energy shortages, China, like the United States, European Union, and other countries, is promoting the development of biofuels. However, China also faces high future demand for food and feed, and so its bioenergy program must try to strike a balance between food and fuel. The goals of this paper are to provide an overview of China's current bioethanol program, identify the potential for using marginal lands for feedstock production, and measure the likely impacts of China's bioethanol development on the nation's future food self-sufficiency. Our results indicate that the potential to use marginal land for bioethanol feedstock production is limited. Applying a modeling approach based on highly disaggregated data by region, our analysis shows that the target of 10 million t of bioethanol by 2020 seems to be a prudent target, causing no major disturbances in China's food security. But the expansion of bioethanol may increase environmental pressures due to the higher levels of fertilizer use. This study shows also that if China were able to cultivate 45% of its required bioethanol feedstock on new marginal land, it would further limit negative effects of the bioethanol program on the domestic and international economy, but at the expense of having to apply another 750 thousand t of fertilizer. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  2. Defining the optimal planning target volume in image-guided stereotactic radiosurgery of brain metastases: results of a randomized trial.

    PubMed

    Kirkpatrick, John P; Wang, Zhiheng; Sampson, John H; McSherry, Frances; Herndon, James E; Allen, Karen J; Duffy, Eileen; Hoang, Jenny K; Chang, Zheng; Yoo, David S; Kelsey, Chris R; Yin, Fang-Fang

    2015-01-01

    To identify an optimal margin about the gross target volume (GTV) for stereotactic radiosurgery (SRS) of brain metastases, minimizing toxicity and local recurrence. Adult patients with 1 to 3 brain metastases less than 4 cm in greatest dimension, no previous brain radiation therapy, and Karnofsky performance status (KPS) above 70 were eligible for this institutional review board-approved trial. Individual lesions were randomized to 1- or 3- mm uniform expansion of the GTV defined on contrast-enhanced magnetic resonance imaging (MRI). The resulting planning target volume (PTV) was treated to 24, 18, or 15 Gy marginal dose for maximum PTV diameters less than 2, 2 to 2.9, and 3 to 3.9 cm, respectively, using a linear accelerator-based image-guided system. The primary endpoint was local recurrence (LR). Secondary endpoints included neurocognition Mini-Mental State Examination, Trail Making Test Parts A and B, quality of life (Functional Assessment of Cancer Therapy-Brain), radionecrosis (RN), need for salvage radiation therapy, distant failure (DF) in the brain, and overall survival (OS). Between February 2010 and November 2012, 49 patients with 80 brain metastases were treated. The median age was 61 years, the median KPS was 90, and the predominant histologies were non-small cell lung cancer (25 patients) and melanoma (8). Fifty-five, 19, and 6 lesions were treated to 24, 18, and 15 Gy, respectively. The PTV/GTV ratio, volume receiving 12 Gy or more, and minimum dose to PTV were significantly higher in the 3-mm group (all P<.01), and GTV was similar (P=.76). At a median follow-up time of 32.2 months, 11 patients were alive, with median OS 10.6 months. LR was observed in only 3 lesions (2 in the 1 mm group, P=.51), with 6.7% LR 12 months after SRS. Biopsy-proven RN alone was observed in 6 lesions (5 in the 3-mm group, P=.10). The 12-month DF rate was 45.7%. Three months after SRS, no significant change in neurocognition or quality of life was observed. SRS was well tolerated, with low rates of LR and RN in both cohorts. However, given the higher potential risk of RN with a 3-mm margin, a 1-mm GTV expansion is more appropriate. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Updated evidence-based clinical practice guidelines for the diagnosis and management of melanoma: definitive excision margins for primary cutaneous melanoma.

    PubMed

    Sladden, Michael J; Nieweg, Omgo E; Howle, Julie; Coventry, Brendon J; Thompson, John F

    2018-02-19

    Definitive management of primary cutaneous melanoma consists of surgical excision of the melanoma with the aim of curing the patient. The melanoma is widely excised together with a safety margin of surrounding skin and subcutaneous tissue, after the diagnosis and Breslow thickness have been established by histological assessment of the initial excision biopsy specimen. Sentinel lymph node biopsy should be discussed for melanomas ≥ 1 mm thickness (≥ 0.8 mm if other high risk features) in which case lymphoscintigraphy must be performed before wider excision of the primary melanoma site. The 2008 evidence-based clinical practice guidelines for the management of melanoma (http://www.cancer.org.au/content/pdf/HealthProfessionals/ClinicalGuidelines/ClinicalPracticeGuidelines-ManagementofMelanoma.pdf) are currently being revised and updated in a staged process by a multidisciplinary working party established by Cancer Council Australia. The guidelines for definitive excision margins for primary melanomas have been revised as part of this process. Main recommendations: The recommendations for definitive wide local excision of primary cutaneous melanoma are: melanoma in situ: 5-10 mm margins invasive melanoma (pT1) ≤ 1.0 mm thick: 1 cm margins invasive melanoma (pT2) 1.01-2.00 mm thick: 1-2 cm margins invasive melanoma (pT3) 2.01-4.00 mm thick: 1-2 cm margins invasive melanoma (pT4) > 4.0 mm thick: 2 cm margins Changes in management as a result of the guideline: Based on currently available evidence, excision margins for invasive melanoma have been left unchanged compared with the 2008 guidelines. However, melanoma in situ should be excised with 5-10 mm margins, with the aim of achieving complete histological clearance. Minimum clearances from all margins should be assessed and stated. Consideration should be given to further excision if necessary; positive or close histological margins are unacceptable.

  4. Genotypic Resistance Tests Sequences Reveal the Role of Marginalized Populations in HIV-1 Transmission in Switzerland

    PubMed Central

    Shilaih, Mohaned; Marzel, Alex; Yang, Wan Lin; Scherrer, Alexandra U.; Schüpbach, Jörg; Böni, Jürg; Yerly, Sabine; Hirsch, Hans H.; Aubert, Vincent; Cavassini, Matthias; Klimkait, Thomas; Vernazza, Pietro L.; Bernasconi, Enos; Furrer, Hansjakob; Günthard, Huldrych F.; Kouyos, Roger; Battegay, Manuel; Braun, Dominique; Bucher, Heiner; Burton-Jeangros, Claudine; Calmy, Alexandra; Dollenmaier, Günter; Egger, Matthias; Elzi, Luigia; Fehr, Jan; Fellay, Jaque; Fux, Christoph; Gorgievski, Meri; Haerry, David; Hasse, Barbara; Hoffmann, Matthias; Hösli, Irene; Kahlert, Christian; Kaiser, Laurent; Keiser, Olivia; Kovari, Helen; Ledergerber, Bruno; Martinetti, Gladys; de Tejada, Begoña Martinez; Marzolini, Catia; Metzner, Karin; Müller, Nicolas; Nadal, David; Nicca, Dunja; Pantaleo, Giuseppe; Rauch, Andre; Regenass, Stephan; Rudin, Christoph; Schöni-Affolter, Franziska; Schmid, Patrick; Speck, Roberto; Stöckle, Marcel; Tarr, Philip; Trkola, Alexandra; Weber, Reiner

    2016-01-01

    Targeting hard-to-reach/marginalized populations is essential for preventing HIV-transmission. A unique opportunity to identify such populations in Switzerland is provided by a database of all genotypic-resistance-tests from Switzerland, including both sequences from the Swiss HIV Cohort Study (SHCS) and non-cohort sequences. A phylogenetic tree was built using 11,127 SHCS and 2,875 Swiss non-SHCS sequences. Demographics were imputed for non-SHCS patients using a phylogenetic proximity approach. Factors associated with non-cohort outbreaks were determined using logistic regression. Non-B subtype (univariable odds-ratio (OR): 1.9; 95% confidence interval (CI): 1.8–2.1), female gender (OR: 1.6; 95% CI: 1.4–1.7), black ethnicity (OR: 1.9; 95% CI: 1.7–2.1) and heterosexual transmission group (OR:1.8; 95% CI: 1.6–2.0), were all associated with underrepresentation in the SHCS. We found 344 purely non-SHCS transmission clusters, however, these outbreaks were small (median 2, maximum 7 patients) with a strong overlap with the SHCS’. 65% of non-SHCS sequences were part of clusters composed of >= 50% SHCS sequences. Our data suggests that marginalized-populations are underrepresented in the SHCS. However, the limited size of outbreaks among non-SHCS patients in-care implies that no major HIV outbreak in Switzerland was missed by the SHCS surveillance. This study demonstrates the potential of sequence data to assess and extend the scope of infectious-disease surveillance. PMID:27297284

  5. Genotypic Resistance Tests Sequences Reveal the Role of Marginalized Populations in HIV-1 Transmission in Switzerland.

    PubMed

    Shilaih, Mohaned; Marzel, Alex; Yang, Wan Lin; Scherrer, Alexandra U; Schüpbach, Jörg; Böni, Jürg; Yerly, Sabine; Hirsch, Hans H; Aubert, Vincent; Cavassini, Matthias; Klimkait, Thomas; Vernazza, Pietro L; Bernasconi, Enos; Furrer, Hansjakob; Günthard, Huldrych F; Kouyos, Roger

    2016-06-14

    Targeting hard-to-reach/marginalized populations is essential for preventing HIV-transmission. A unique opportunity to identify such populations in Switzerland is provided by a database of all genotypic-resistance-tests from Switzerland, including both sequences from the Swiss HIV Cohort Study (SHCS) and non-cohort sequences. A phylogenetic tree was built using 11,127 SHCS and 2,875 Swiss non-SHCS sequences. Demographics were imputed for non-SHCS patients using a phylogenetic proximity approach. Factors associated with non-cohort outbreaks were determined using logistic regression. Non-B subtype (univariable odds-ratio (OR): 1.9; 95% confidence interval (CI): 1.8-2.1), female gender (OR: 1.6; 95% CI: 1.4-1.7), black ethnicity (OR: 1.9; 95% CI: 1.7-2.1) and heterosexual transmission group (OR:1.8; 95% CI: 1.6-2.0), were all associated with underrepresentation in the SHCS. We found 344 purely non-SHCS transmission clusters, however, these outbreaks were small (median 2, maximum 7 patients) with a strong overlap with the SHCS'. 65% of non-SHCS sequences were part of clusters composed of >= 50% SHCS sequences. Our data suggests that marginalized-populations are underrepresented in the SHCS. However, the limited size of outbreaks among non-SHCS patients in-care implies that no major HIV outbreak in Switzerland was missed by the SHCS surveillance. This study demonstrates the potential of sequence data to assess and extend the scope of infectious-disease surveillance.

  6. Abutment Disconnection/Reconnection Affects Peri-implant Marginal Bone Levels: A Meta-Analysis.

    PubMed

    Koutouzis, Theofilos; Gholami, Fatemeh; Reynolds, John; Lundgren, Tord; Kotsakis, Georgios A

    Preclinical and clinical studies have shown that marginal bone loss can be secondary to repeated disconnection and reconnection of abutments that affect the peri-implant mucosal seal. The aim of this systematic review and meta-analysis was to evaluate the impact of abutment disconnections/reconnections on peri-implant marginal bone level changes. To address this question, two reviewers independently performed an electronic search of three major databases up to October 2015 complemented by manual searches. Eligible articles were selected on the basis of prespecified inclusion and exclusion criteria after a two-phase search strategy and assessed for risk of bias. A random-effects meta-analysis was performed for marginal bone loss. The authors initially identified 392 titles and abstracts. After evaluation, seven controlled clinical studies were included. Qualitative assessment of the articles revealed a trend toward protective marginal bone level preservation for implants with final abutment placement (FAP) at the time of implant placement compared with implants for which there were multiple abutment placements (MAP). The FAP group exhibited a marginal bone level change ranging from 0.08 to 0.34 mm, whereas the MAP group exhibited a marginal bone level change ranging from 0.09 to 0.55 mm. Meta-analysis of the seven studies reporting on 396 implants showed significantly greater bone loss in cases of multiple abutment disconnections/reconnections. The weighted mean difference in marginal bone loss was 0.19 mm (95% confidence interval, 0.06-0.32 mm), favoring bone preservation in the FAP group. Within the limitations of this meta-analysis, abutment disconnection and reconnection significantly affected peri-implant marginal bone levels. These findings pave the way for revisiting current restorative protocols at the restorative treatment planning stage to prevent incipient marginal bone loss.

  7. Molecular pathogenesis of splenic and nodal marginal zone lymphoma.

    PubMed

    Spina, Valeria; Rossi, Davide

    Genomic studies have improved our understanding of the biological basis of splenic (SMZL) and nodal (NMZL) marginal zone lymphoma by providing a comprehensive and unbiased view of the genes/pathways that are deregulated in these diseases. Consistent with the physiological involvement of NOTCH, NF-κB, B-cell receptor and toll-like receptor signaling in mature B-cells differentiation into the marginal zone B-cells, many oncogenic mutations of genes involved in these pathways have been identified in SMZL and NMZL. Beside genetic lesions, also epigenetic and post-transcriptional modifications contribute to the deregulation of marginal zone B-cell differentiation pathways in SMZL and NMZL. This review describes the progress in understanding the molecular mechanism underlying SMZL and NMZL, including molecular and post-transcriptional modifications, and discusses how information gained from these efforts has provided new insights on potential targets of diagnostic, prognostic and therapeutic relevance in SMZL and NMZL. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. The tumour border on contrast-enhanced spectral mammography and its relation to histological characteristics of invasive breast cancer.

    PubMed

    Ambicka, Aleksandra; Luczynska, Elzbieta; Adamczyk, Agnieszka; Harazin-Lechowska, Agnieszka; Sas-Korczynska, Beata; Niemiec, Joanna

    Contrast-enhanced spectral mammography (CESM) is one of the new diagnostic modalities implemented in clinical practice. In the case of these techniques, there are two major issues to be addressed: (1) their diagnostic usefulness, and (2) the relation between parameters assessed using these techniques and well-known diagnostic/prognostic/predictive markers (histological, clinical, and molecular). Therefore, we studied the relationship between the tumour margin assessed on CESM and (1) tumour borders defined on the basis of macroscopic and microscopic examination, (2) pT, (3) pN, and (4) tumour grade in a group of 82 breast cancer patients. Based on CESM, the tumour border was defined as sharp, indistinct or spiculated, whereas in the case of lesions showing weak or medium enhancement on CESM the borders were classified as unspecified. We found a statistically significant relationship between tumour margin on CESM and (1) macroscopic border (a spiculated margin on CESM was found only in carcinomas with an invasive border on histological examination; p = 0.004), (2) pT (p = 0.016), and (3) pN (nodal involvement was observed most frequently in carcinomas with a spiculated or indistinct margin on CESM; p = 0.045). Moreover, in cases with an undefined margin on CESM (cases showing weak or medium enhancement on CESM), both invasive and pushing borders were found on histological examination. The results of our preliminary study suggest that it is possible to assess macroscopic borders of examined lesions on the basis of CESM imaging. This might be useful in planning the extent of surgical excision. On the other hand, the assessment of the tumour margin on CESM might not be precise in cases showing weak enhancement.

  9. Accelerated partial breast irradiation using 3D conformal radiotherapy: toxicity and cosmetic outcome.

    PubMed

    Gatti, M; Ponzone, R; Bresciani, S; Panaia, R; Kubatzki, F; Maggiorotto, F; Di Virgilio, M R; Salatino, A; Baiotto, B; Montemurro, F; Stasi, M; Gabriele, P

    2013-12-01

    The aim of this paper is to analyze the incidence of acute and late toxicity and cosmetic outcome in breast cancer patients submitted to breast conserving surgery and three-dimensional conformal radiotherapy (3D-CRT) to deliver accelerated partial breast irradiation (APBI). 84 patients were treated with 3D-CRT for APBI. This technique was assessed in patients with low risk stage I breast cancer enrolled from September 2005 to July 2011. The prescribed dose was 34/38.5 Gy delivered in 10 fractions twice daily over 5 consecutive days. Four to five no-coplanar 6 MV beams were used. In all CT scans Gross Tumor Volume (GTV) was defined around the surgical clips. A 1.5 cm margin was added by defining a Clinical Target Volume (CTV). A margin of 1 cm was added to CTV to define the planning target volume (PTV). The dose-volume constraints were followed in accordance with the NSABP/RTOG protocol. Late toxicity was evaluated according to the RTOG grading schema. The cosmetic assessment was performed using the Harvard scale. Median patient age was 66 years (range 51-87). Median follow-up was 36.5 months (range 13-83). The overall incidence of acute skin toxicities was 46.4% for grade 1 and 1% for grade 2. The incidence of late toxicity was 16.7% for grade 1, 2.4% for grade 2 and 3.6% for grade 3. No grade 4 toxicity was observed. The most pronounced grade 2 late toxicity was telangiectasia, developed in three patients. Cosmetics results were excellent for 52%, good for 42%, fair for 5% and poor for 1% of the patients. There was no statistical correlation between toxicity rates and prescribed doses (p = 0.33) or irradiated volume (p = 0.45). APBI using 3D-CRT is technically feasible with very low acute and late toxicity. Long-term results are needed to assess its efficacy in reducing the incidence of breast relapse. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Target Practice? Using the Arts for Social Inclusion

    ERIC Educational Resources Information Center

    Lynch, Heather; Allan, Julie

    2007-01-01

    Use of creative processes as a tool for social inclusion has gathered momentum in recent years. This article reports the views of education professionals based in Scotland on the use and effects of targeting. While this strategy aims to improve access to those communities considered marginal, it is apparent that some of the effects are detrimental…

  11. Post-resection mucosal margin shrinkage in oral cancer: quantification and significance.

    PubMed

    Mistry, Rajesh C; Qureshi, Sajid S; Kumaran, C

    2005-08-01

    The importance of tumor free margins in outcome of cancer surgery is well known. Often the pathological margins are reported to be significantly smaller than the in situ margins. This discrepancy is due to margin shrinkage the quantum of which has not been studied in patients with oral cancers. To quantify the shrinkage of mucosal margin following excision for carcinoma of the oral tongue and buccal mucosa. Mucosal margins were measured prior to resection and half an hour after excision in 27 patients with carcinoma of the tongue and buccal mucosa. The mean margin shrinkage was assessed and the variables affecting the quantum of shrinkage analyzed. The mean shrinkage from the in situ to the post resection margin status was 22.7% (P < 0.0001). The mean shrinkage of the tongue margins was 23.5%, compared to 21.2% for buccal mucosa margins. The mean shrinkage in T1/T2 tumors (25.6%) was significantly more than in T3/T4 (9.2%, P < 0.011). There is significant shrinkage of mucosal margins after surgery. Hence this should be considered and appropriate margins should be taken at initial resection to prevent the agony of post-operative positive surgical margins. Copyright 2005 Wiley-Liss, Inc.

  12. Microleakage of Four Dental Cements in Metal Ceramic Restorations With Open Margins.

    PubMed

    Eftekhar Ashtiani, Reza; Farzaneh, Babak; Azarsina, Mohadese; Aghdashi, Farzad; Dehghani, Nima; Afshari, Aisooda; Mahshid, Minu

    2015-11-01

    Fixed prosthodontics is a routine dental treatment and microleakage is a major cause of its failure. The aim of this study was to assess the marginal microleakage of four cements in metal ceramic restorations with adapted and open margins. Sixty sound human premolars were selected for this experimental study performed in Tehran, Iran and prepared for full-crown restorations. Wax patterns were formed leaving a 300 µm gap on one of the proximal margins. The crowns were cast and the samples were randomly divided into four groups based on the cement used. Copings were cemented using zinc phosphate cement (Fleck), Fuji Plus resin-modified glass ionomer, Panavia F2.0 resin cement, or G-Cem resin cement, according to the manufacturers' instructions. Samples were immersed in 2% methylene blue solution. After 24 hours, dye penetration was assessed under a stereomicroscope and analyzed using the respective software. Data were analyzed using ANOVA, paired t-tests, and Kruskal-Wallis, Wilcoxon, and Mann-Whitney tests. The least microleakage occurred in the Panavia F2.0 group (closed margin, 0.18 mm; open margin, 0.64 mm) and the maximum was observed in the Fleck group (closed margin, 1.92 mm; open margin, 3.32 mm). The Fleck group displayed significantly more microleakage compared to the Fuji Plus and Panavia F2.0 groups (P < 0.001) in both closed and open margins. In open margins, differences in microleakage between the Fuji Plus and G-Cem as well as between the G-Cem and Panavia F2.0 groups were significant (P < 0.001). In closed margins, only the G-Cem group displayed significantly more microleakage as compared to the Panavia F2.0 group (P < 0.05). Paired t-test results showed significantly more microleakage in open margins compared to closed margins, except in the Fuji Plus group (P = 0.539). Fuji Plus cement exhibited better sealing ability in closed and open margins compared to G-Cem and Fleck cements. When using G-Cem and Fleck cements for full metal ceramic restorations, clinicians should try to minimize marginal gaps in order to reduce restoration failure. In situations where there are doubts about perfect marginal adaptation, the use of Fuji Plus cement may be helpful.

  13. Margin to tumor thickness ratio - A predictor of local recurrence and survival in oral squamous cell carcinoma.

    PubMed

    Heiduschka, Gregor; Virk, Sohaib A; Palme, Carsten E; Ch'ng, Sydney; Elliot, Michael; Gupta, Ruta; Clark, Jonathan

    2016-04-01

    To assess whether small oral squamous cell carcinomas (OSCC) require the same margin clearance as large tumors. We evaluated the association between the ratio of the closest margin to tumor size (MSR) and tumor thickness (MTR) with local control and survival. The clinicopathologic and follow up data were obtained for 501 OSCC patients who had surgical resection with curative intent at our institution. MTR and MSR were computed and their associations with local control and survival were assessed using multivariable Cox-regression model. Survival curves were generated using the Kaplan-Meier method. MTR was a better predictor of disease control than MSR. MTR was a predictor of local failure (p=0.033) and disease specific death (p=0.038) after adjusting for perineural invasion, lymphovascular involvement, nodal status, and radiotherapy. A threshold MTR value of 0.3 was identified, above which the risk of local recurrence was low. The ratio of margin to tumor thickness was an independent predictor for local recurrence and disease specific death in this cohort. A MTR>0.3 can serve as a useful tool for adjuvant therapy planning as it combines tumor thickness and margin clearance, two well established prognostic factors. The minimum safe margin can be calculated by multiplying the tumor thickness by 0.3. Further prospective studies in other institutions are warranted to confirm the prognostic utility of MTR and assess the generalizability of our threshold values. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Projected gains and losses of wildlife habitat from bioenergy-induced landscape change

    USGS Publications Warehouse

    Tarr, Nathan M.; Rubino, Matthew J.; Costanza, Jennifer K.; McKerrow, Alexa; Collazo, Jaime A.; Abt, Robert C.

    2016-01-01

    Domestic and foreign renewable energy targets and financial incentives have increased demand for woody biomass and bioenergy in the southeastern United States. This demand is expected to be met through purpose-grown agricultural bioenergy crops, short-rotation tree plantations, thinning and harvest of planted and natural forests, and forest harvest residues. With results from a forest economics model, spatially explicit state-and-transition simulation models, and species–habitat models, we projected change in habitat amount for 16 wildlife species caused by meeting a renewable fuel target and expected demand for wood pellets in North Carolina, USA. We projected changes over 40 years under a baseline ‘business-as-usual’ scenario without bioenergy production and five scenarios with unique feedstock portfolios. Bioenergy demand had potential to influence trends in habitat availability for some species in our study area. We found variation in impacts among species, and no scenario was the ‘best’ or ‘worst’ across all species. Our models projected that shrub-associated species would gain habitat under some scenarios because of increases in the amount of regenerating forests on the landscape, while species restricted to mature forests would lose habitat. Some forest species could also lose habitat from the conversion of forests on marginal soils to purpose-grown feedstocks. The conversion of agricultural lands on marginal soils to purpose-grown feedstocks increased habitat losses for one species with strong associations with pasture, which is being lost to urbanization in our study region. Our results indicate that landscape-scale impacts on wildlife habitat will vary among species and depend upon the bioenergy feedstock portfolio. Therefore, decisions about bioenergy and wildlife will likely involve trade-offs among wildlife species, and the choice of focal species is likely to affect the results of landscape-scale assessments. We offer general principals to consider when crafting lists of focal species for bioenergy impact assessments at the landscape scale.

  15. Spatial distribution of Aglais urticae (L.) and its host plant Urtica dioica (L.) in an agricultural landscape: implications for Bt maize risk assessment and post-market monitoring.

    PubMed

    Gathmann, Achim; Wirooks, Ludger; Eckert, Jörg; Schuphan, Ingolf

    2006-01-01

    Over the past decades, genes of Bacillus thuringiensis var. kurstaki (Berliner) (Bt) coding for protein toxins have been engineered into maize for protection against the European Corn Borer (Ostrinia nubilalis (Hbn.)). However, these transgenic plants may have an impact on non-target organisms. In particular, a potential hazard was identified for non-target lepidopteran larvae, if they consume Bt maize pollen on their host plants. Risk can be defined as a function of the effect of an event (hazard) and the likelihood of this event occurring. Although data on toxicity (hazard) are available from many lab and field studies, knowledge about the environmental exposure of European lepidopteran larvae is incomplete at the population level. Therefore we studied the distribution of small tortoiseshell caterpillars (Aglais urticae (L.)) and its host plant in an agricultural landscape in Germany, to estimate the potential population exposure to maize pollen. The results showed that larvae of the small tortoiseshell developed primarily on freshly sprouted nettle stands (Urtica dioica (L.)) in field margins, rather than adjacent to hedges and groves. However, the main distribution was at margins of cereal (non-maize) fields, where 70% of all larvae were found. This may be due the fact that cereals covered 54% of the survey area, while maize only covered 6.1%. On the other hand, maize fields seem so show higher food plant densities than cereal crops. The results must be interpreted carefully, as the data basis of the present study is very small, and the situation can vary between years due to crop rotation or other changes in agricultural practices. Therefore it is still questionable whether the small tortoiseshell is significantly exposed to maize pollen. For a conclusive risk assessment, more replications and surveys of larger areas in different intensively managed agricultural landscapes over several years are needed.

  16. SU-G-JeP3-12: Use of Cone Beam CT and Deformable Image Registration for Assessing Geometrical and Dosimetric Variations During Lung Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jurkovic, I; Stathakis, S; Markovic, M

    Purpose: To assess the value of cone beam CT (CBCT) combined with deformable image registration in estimating the accuracy of the delivered treatment and the suitability of the applied target margins. Methods: Two patients with lung tumor were selected. Using their CT images intensity modulated radiation therapy (IMRT) treatment plans were developed to deliver 66Gy to the 95% of the PTV in 2Gy fractions. Using the Velocity AI software, the planning CT of each patient was registered with the fractional CBCT images that were obtained through the course of the treatment. After a CT to CBCT deformable image registration (DIR),more » the same fractional deformation matrix was used for the deformation of the planned dose distributions, as well as of all the contoured volumes, to each CBCT dataset. The dosimetric differences between the planning target volume (PTV) and various organs at risk (OARs) were recorded and compared. Results: CBCT data such as CTV volume change and PTV coverage was analyzed. There was a moderate relationship between volume changes and contouring method (automatic contouring using the DIR transformation vs. manual contouring on each CBCT) for patient #1 (r = 0.49), and a strong relationship for patient #2 (r = 0.83). The average PTV volume coverage from all the CBCT datasets was 91.2% for patient #1 and 95.6% for patient #2. Conclusion: Daily setup variations, tumor volume motion and lung deformation due to breathing yield differences in the actual delivered dose distributions versus the planned ones. The results presented indicate that these differences are apparent even with the use of daily IGRT. In certain fractions, the margins used seem to be insufficient to ensure acceptable lung tumor coverage. The observed differences notably depend on the tumor volume size and location. A larger cohort of patient is under investigation to verify those findings.« less

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cui, G; Trakul, N; Chang, E

    Purpose: To evaluate the reproducibility of target position using moderate voluntary breath-hold during liver stereotactic ablative radiotherapy (SABR). Methods: Two patients who underwent liver SABR on a Varian TrueBeam STx linac were used for this study. Fiducial markers were placed in and around the target in the liver as surrogates for the target position and motion. GTVs were contoured by assessing tumor extent on contrast enhanced CT. The PTV was created from the GTV by adding 2 mm margins to account for the residual motion during breath-holds. A portable biofeedback system was used to facilitate the breath-hold to a reproduciblemore » position. The Varian RPM system was used for gating the linac. Proceeding each treatment, orthogonal kV pairs were taken, and alignment to nearby bony anatomy was performed. Then the breath-hold CBCT was acquired to align the fiducial markers. On-line fluoroscopy was used to fine-tune the breath-hold gating thresholds to correlate with the positions of the fiducial markers. The inter-fraction reproducibility of the target was evaluated by the offsets of the daily breath-hold CBCTs from the paired kV matches as a direct measure of the target position relative to the bony anatomy. The intra-fraction reproducibility of the target position was assessed by the gated window of the RPM marker block for each fraction. Results: The absolute mean offsets between the CBCT and paired kV matches in the vertical, longitudinal, and lateral directions were 0.06 cm, 0.10 cm, and 0.06 cm for patient 1, and 0.37 cm, 0.62 cm, and 0.09 cm for patient 2. The gated window of the RPM marker block for the breath-hold for each fraction was within 0.63 ± 0.16 cm and 0.59 ± 0.12 cm for patients 1 and 2, respectively. Conclusion: Moderate voluntary breath-hold showed good inter- and intra-fraction reproducibility of target position during liver SABR.« less

  18. A Fast, Efficient Domain Adaptation Technique for Cross-Domain Electroencephalography(EEG)-Based Emotion Recognition

    PubMed Central

    Chai, Xin; Wang, Qisong; Zhao, Yongping; Li, Yongqiang; Liu, Dan; Liu, Xin; Bai, Ou

    2017-01-01

    Electroencephalography (EEG)-based emotion recognition is an important element in psychiatric health diagnosis for patients. However, the underlying EEG sensor signals are always non-stationary if they are sampled from different experimental sessions or subjects. This results in the deterioration of the classification performance. Domain adaptation methods offer an effective way to reduce the discrepancy of marginal distribution. However, for EEG sensor signals, both marginal and conditional distributions may be mismatched. In addition, the existing domain adaptation strategies always require a high level of additional computation. To address this problem, a novel strategy named adaptive subspace feature matching (ASFM) is proposed in this paper in order to integrate both the marginal and conditional distributions within a unified framework (without any labeled samples from target subjects). Specifically, we develop a linear transformation function which matches the marginal distributions of the source and target subspaces without a regularization term. This significantly decreases the time complexity of our domain adaptation procedure. As a result, both marginal and conditional distribution discrepancies between the source domain and unlabeled target domain can be reduced, and logistic regression (LR) can be applied to the new source domain in order to train a classifier for use in the target domain, since the aligned source domain follows a distribution which is similar to that of the target domain. We compare our ASFM method with six typical approaches using a public EEG dataset with three affective states: positive, neutral, and negative. Both offline and online evaluations were performed. The subject-to-subject offline experimental results demonstrate that our component achieves a mean accuracy and standard deviation of 80.46% and 6.84%, respectively, as compared with a state-of-the-art method, the subspace alignment auto-encoder (SAAE), which achieves values of 77.88% and 7.33% on average, respectively. For the online analysis, the average classification accuracy and standard deviation of ASFM in the subject-to-subject evaluation for all the 15 subjects in a dataset was 75.11% and 7.65%, respectively, gaining a significant performance improvement compared to the best baseline LR which achieves 56.38% and 7.48%, respectively. The experimental results confirm the effectiveness of the proposed method relative to state-of-the-art methods. Moreover, computational efficiency of the proposed ASFM method is much better than standard domain adaptation; if the numbers of training samples and test samples are controlled within certain range, it is suitable for real-time classification. It can be concluded that ASFM is a useful and effective tool for decreasing domain discrepancy and reducing performance degradation across subjects and sessions in the field of EEG-based emotion recognition. PMID:28467371

  19. A Fast, Efficient Domain Adaptation Technique for Cross-Domain Electroencephalography(EEG)-Based Emotion Recognition.

    PubMed

    Chai, Xin; Wang, Qisong; Zhao, Yongping; Li, Yongqiang; Liu, Dan; Liu, Xin; Bai, Ou

    2017-05-03

    Electroencephalography (EEG)-based emotion recognition is an important element in psychiatric health diagnosis for patients. However, the underlying EEG sensor signals are always non-stationary if they are sampled from different experimental sessions or subjects. This results in the deterioration of the classification performance. Domain adaptation methods offer an effective way to reduce the discrepancy of marginal distribution. However, for EEG sensor signals, both marginal and conditional distributions may be mismatched. In addition, the existing domain adaptation strategies always require a high level of additional computation. To address this problem, a novel strategy named adaptive subspace feature matching (ASFM) is proposed in this paper in order to integrate both the marginal and conditional distributions within a unified framework (without any labeled samples from target subjects). Specifically, we develop a linear transformation function which matches the marginal distributions of the source and target subspaces without a regularization term. This significantly decreases the time complexity of our domain adaptation procedure. As a result, both marginal and conditional distribution discrepancies between the source domain and unlabeled target domain can be reduced, and logistic regression (LR) can be applied to the new source domain in order to train a classifier for use in the target domain, since the aligned source domain follows a distribution which is similar to that of the target domain. We compare our ASFM method with six typical approaches using a public EEG dataset with three affective states: positive, neutral, and negative. Both offline and online evaluations were performed. The subject-to-subject offline experimental results demonstrate that our component achieves a mean accuracy and standard deviation of 80.46% and 6.84%, respectively, as compared with a state-of-the-art method, the subspace alignment auto-encoder (SAAE), which achieves values of 77.88% and 7.33% on average, respectively. For the online analysis, the average classification accuracy and standard deviation of ASFM in the subject-to-subject evaluation for all the 15 subjects in a dataset was 75.11% and 7.65%, respectively, gaining a significant performance improvement compared to the best baseline LR which achieves 56.38% and 7.48%, respectively. The experimental results confirm the effectiveness of the proposed method relative to state-of-the-art methods. Moreover, computational efficiency of the proposed ASFM method is much better than standard domain adaptation; if the numbers of training samples and test samples are controlled within certain range, it is suitable for real-time classification. It can be concluded that ASFM is a useful and effective tool for decreasing domain discrepancy and reducing performance degradation across subjects and sessions in the field of EEG-based emotion recognition.

  20. Comparative assessment of marginal accuracy of grade II titanium and Ni–Cr alloy before and after ceramic firing: An in vitro study

    PubMed Central

    Patil, Abhijit; Singh, Kishan; Sahoo, Sukant; Suvarna, Suraj; Kumar, Prince; Singh, Anupam

    2013-01-01

    Objective: The aims of the study are to assess the marginal accuracy of base metal and titanium alloy casting and to evaluate the effect of repeated ceramic firing on the marginal accuracy of base metal and titanium alloy castings. Materials and Methods: Twenty metal copings were fabricated with each casting material. Specimens were divided into 4 groups of 10 each representing base metal alloys castings without (Group A) and with metal shoulder margin (Group B), titanium castings without (Group C) and with metal shoulder margin (Group D). The measurement of fit of the metal copings was carried out before the ceramic firing at four different points and the same was followed after porcelain build-up. Results: Significant difference was found when Ni–Cr alloy samples were compared with Grade II titanium samples both before and after ceramic firings. The titanium castings with metal shoulder margin showed highest microgap among all the materials tested. Conclusions: Based on the results that were found and within the limitations of the study design, it can be concluded that there is marginal discrepancy in the copings made from Ni–Cr and Grade II titanium. This marginal discrepancy increased after ceramic firing cycles for both Ni–Cr and Grade II titanium. The comparative statistical analysis for copings with metal-collar showed maximum discrepancy for Group D. The comparative statistical analysis for copings without metal-collar showed maximum discrepancy for Group C. PMID:24926205

  1. Identifying technology innovations for marginalized smallholders-A conceptual approach.

    PubMed

    Malek, Mohammad Abdul; Gatzweiler, Franz W; Von Braun, Joachim

    2017-05-01

    This paper adds a contribution in the existing literature in terms of theoretical and conceptual background for the identification of idle potentials of marginal rural areas and people by means of technological and institutional innovations. The approach follows ex-ante assessment for identifying suitable technology and institutional innovations for marginalized smallholders in marginal areas-divided into three main parts (mapping, surveying and evaluating) and several steps. Finally, it contributes to the inclusion of marginalized smallholders by an improved way of understanding the interactions between technology needs, farming systems, ecological resources and poverty characteristics in the different segments of the poor, and to link these insights with productivity enhancing technologies.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, M; Pompos, A; Gu, X

    Purpose: To characterize the dose distributions of Cyberknife and intensity-modulated-proton-therapy (IMPT). Methods: A total of 20 patients previously treated with Cyberknife were selected. The original planning-target-volume (PTV) was used in the ‘IMPT-ideal’ plan assuming a comparable image-guidance with Cyberknife. A 3mm expansion was made to create the proton-PTV for the ‘IMPT-3mm’ plan representing the current proton-therapy where a margin of 3mm is used to account for the inferior image-guidance. The proton range uncertainty was taken-care in beam-design by adding the proximal- and distal-margins (3%water-equivalent-depth+1mm) for both proton plans. The IMPT plans were generated to meet the same target coverage asmore » the Cyberknife-plans. The plan quality of IMPT-ideal and IMPT-3mm were compared to the Cyberknife-plan. To characterize plan quality, we defined the ratio(R) of volumes encompassed by the selected isodose surfaces for Cyberknife and IMPT plans (VCK/VIMPT). Comparisons were made for both Cyberknife versus IMPT-ideal and Cyberknife versusIMPT-3mm to further discuss the impact of setup error margins used in proton therapy and the correlation with target size and location. Results: IMPT-ideal plans yield comparable plan quality as CK plans and slightly better OAR sparing while the IMPT-3mm plan results in a higher dose to the OARs, especially for centralized tumors. Comparing to the IMPT-ideal plans, a slightly larger 80% (Ravg=1.05) dose cloud and significantly larger 50% (Ravg=1.3) and 20% (Ravg=1.60) dose clouds are seen in CK plans. However, the 3mm expansion results in a larger high and medium dose clouds in IMPT-3mm plans (Ravg=0.65 for 80%-isodose; Ravg=0.93 for 50%-isodose). The trend increases with the size of the target and the distance from the brainstem to the center of target. Conclusion: Cyberknife is more preferable for treating centralized targets and proton therapy is advantageous for the large and peripheral targets. Advanced image guidance would improve the efficacy of proton therapy for intracranial treatments.« less

  3. In Vivo and Ex Vivo Confocal Microscopy for Dermatologic and Mohs Surgeons.

    PubMed

    Longo, Caterina; Ragazzi, Moira; Rajadhyaksha, Milind; Nehal, Kishwer; Bennassar, Antoni; Pellacani, Giovanni; Malvehy Guilera, Josep

    2016-10-01

    Confocal microscopy is a modern imaging device that has been extensively applied in skin oncology. More specifically, for tumor margin assessment, it has been used in two modalities: reflectance mode (in vivo on skin patient) and fluorescence mode (on freshly excised specimen). Although in vivo reflectance confocal microscopy is an add-on tool for lentigo maligna mapping, fluorescence confocal microscopy is far superior for basal cell carcinoma and squamous cell carcinoma margin assessment in the Mohs setting. This article provides a comprehensive overview of the use of confocal microscopy for skin cancer margin evaluation. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Fluorescence lifetime-based contrast enhancement of indocyanine green-labeled tumors

    NASA Astrophysics Data System (ADS)

    Kumar, Anand T. N.; Carp, Stefan A.; Yang, Jing; Ross, Alana; Medarova, Zdravka; Ran, Chongzhao

    2017-04-01

    Although the development of tumor-targeted fluorescent probes is a major area of investigation, it will be several years before these probes are realized for clinical use. Here, we report an approach that employs indocyanine-green (ICG), a clinically approved, nontargeted dye, in conjunction with fluorescence lifetime (FLT) detection to provide high accuracy for tumor-tissue identification in mouse models of subcutaneous human breast and brain tmors. The improved performance relies on the distinct FLTs of ICG within tumors versus tissue autofluorescence and is further aided by the well-known enhanced permeability and retention of ICG in tumors and the clearance of ICG from normal tissue several hours after intravenous injection. We demonstrate that FLT detection can provide more than 98% sensitivity and specificity, and a 10-fold reduction in error rates compared to intensity-based detection. Our studies suggest the significant potential of FLT-contrast for accurate tumor-tissue identification using ICG and other targeted probes under development, both for intraoperative imaging and for ex-vivo margin assessment of surgical specimens.

  5. Xmsx-1 modifies mesodermal tissue pattern along dorsoventral axis in Xenopus laevis embryo.

    PubMed

    Maeda, R; Kobayashi, A; Sekine, R; Lin, J J; Kung, H; Maéno, M

    1997-07-01

    This study analyzes the expression and the function of Xenopus msx-1 (Xmsx-1) in embryos, in relation to the ventralizing activity of bone morphogenetic protein-4 (BMP-4). Expression of Xmsx-1 was increased in UV-treated ventralized embryos and decreased in LiCl-treated dorsalized embryos at the neurula stage (stage 14). Whole-mount in situ hybridization analysis showed that Xmsx-1 is expressed in marginal zone and animal pole areas, laterally and ventrally, but not dorsally, at mid-gastrula (stage 11) and late-gastrula (stage 13) stages. Injection of BMP-4 RNA, but not activin RNA, induced Xmsx-1 expression in the dorsal marginal zone at the early gastrula stage (stage 10+), and introduction of a dominant negative form of BMP-4 receptor RNA suppressed Xmsx-1 expression in animal cap and ventral marginal zone explants at stage 14. Thus, Xmsx-1 is a target gene specifically regulated by BMP-4 signaling. Embryos injected with Xmsx-1 RNA in dorsal blastomeres at the 4-cell stage exhibited a ventralized phenotype, with microcephaly and swollen abdomen. Histological observation and immunostaining revealed that these embryos had a large block of muscle tissue in the dorsal mesodermal area instead of notochord. On the basis of molecular marker analysis, however, the injection of Xmsx-1 RNA did not induce the expression of alpha-globin, nor reduce cardiac alpha-actin in dorsal marginal zone explants. Furthermore, a significant amount of alpha-actin was induced and alpha-globin was turned off in the ventral marginal zone explants injected with Xmsx-1. These results indicated that Xmsx-1 is a target gene of BMP-4 signaling, but possesses a distinct activity on dorsal-ventral patterning of mesodermal tissues.

  6. Marginalizing Instrument Systematics in HST WFC3 Transit Light Curves

    NASA Astrophysics Data System (ADS)

    Wakeford, H. R.; Sing, D. K.; Evans, T.; Deming, D.; Mandell, A.

    2016-03-01

    Hubble Space Telescope (HST) Wide Field Camera 3 (WFC3) infrared observations at 1.1-1.7 μm probe primarily the H2O absorption band at 1.4 μm, and have provided low-resolution transmission spectra for a wide range of exoplanets. We present the application of marginalization based on Gibson to analyze exoplanet transit light curves obtained from HST WFC3 to better determine important transit parameters such as Rp/R*, which are important for accurate detections of H2O. We approximate the evidence, often referred to as the marginal likelihood, for a grid of systematic models using the Akaike Information Criterion. We then calculate the evidence-based weight assigned to each systematic model and use the information from all tested models to calculate the final marginalized transit parameters for both the band-integrated and spectroscopic light curves to construct the transmission spectrum. We find that a majority of the highest weight models contain a correction for a linear trend in time as well as corrections related to HST orbital phase. We additionally test the dependence on the shift in spectral wavelength position over the course of the observations and find that spectroscopic wavelength shifts {δ }λ (λ ) best describe the associated systematic in the spectroscopic light curves for most targets while fast scan rate observations of bright targets require an additional level of processing to produce a robust transmission spectrum. The use of marginalization allows for transparent interpretation and understanding of the instrument and the impact of each systematic evaluated statistically for each data set, expanding the ability to make true and comprehensive comparisons between exoplanet atmospheres.

  7. Marginalizing Instrument Systematics in HST WFC3 Transit Light Curves

    NASA Technical Reports Server (NTRS)

    Wakeford, H. R.; Sing, D.K.; Deming, D.; Mandell, A.

    2016-01-01

    Hubble Space Telescope (HST) Wide Field Camera 3 (WFC3) infrared observations at 1.1-1.7 microns probe primarily the H2O absorption band at 1.4 microns, and have provided low-resolution transmission spectra for a wide range of exoplanets. We present the application of marginalization based on Gibson to analyze exoplanet transit light curves obtained from HST WFC3 to better determine important transit parameters such as "ramp" probability (R (sub p)) divided by "ramp" total (R (sub asterisk)), which are important for accurate detections of H2O. We approximate the evidence, often referred to as the marginal likelihood, for a grid of systematic models using the Akaike Information Criterion. We then calculate the evidence-based weight assigned to each systematic model and use the information from all tested models to calculate the final marginalized transit parameters for both the band-integrated and spectroscopic light curves to construct the transmission spectrum. We find that a majority of the highest weight models contain a correction for a linear trend in time as well as corrections related to HST orbital phase. We additionally test the dependence on the shift in spectral wavelength position over the course of the observations and find that spectroscopic wavelength shifts delta (sub lambda) times lambda) best describe the associated systematic in the spectroscopic light curves for most targets while fast scan rate observations of bright targets require an additional level of processing to produce a robust transmission spectrum. The use of marginalization allows for transparent interpretation and understanding of the instrument and the impact of each systematic evaluated statistically for each data set, expanding the ability to make true and comprehensive comparisons between exoplanet atmospheres.

  8. Farm systems assessment of bioenergy feedstock production: Integrating bio-economic models and life cycle analysis approaches

    PubMed Central

    Glithero, N.J.; Ramsden, S.J.; Wilson, P.

    2012-01-01

    Climate change and energy security concerns have driven the development of policies that encourage bioenergy production. Meeting EU targets for the consumption of transport fuels from bioenergy by 2020 will require a large increase in the production of bioenergy feedstock. Initially an increase in ‘first generation’ biofuels was observed, however ‘food competition’ concerns have generated interest in second generation biofuels (SGBs). These SGBs can be produced from co-products (e.g. cereal straw) or energy crops (e.g. miscanthus), with the former largely negating food competition concerns. In order to assess the sustainability of feedstock supply for SGBs, the financial, environmental and energy costs and benefits of the farm system must be quantified. Previous research has captured financial costs and benefits through linear programming (LP) approaches, whilst environmental and energy metrics have been largely been undertaken within life cycle analysis (LCA) frameworks. Assessing aspects of the financial, environmental and energy sustainability of supplying co-product second generation biofuel (CPSGB) feedstocks at the farm level requires a framework that permits the trade-offs between these objectives to be quantified and understood. The development of a modelling framework for Managing Energy and Emissions Trade-Offs in Agriculture (MEETA Model) that combines bio-economic process modelling and LCA is presented together with input data parameters obtained from literature and industry sources. The MEETA model quantifies arable farm inputs and outputs in terms of financial, energy and emissions results. The model explicitly captures fertiliser: crop-yield relationships, plus the incorporation of straw or removal for sale, with associated nutrient impacts of incorporation/removal on the following crop in the rotation. Key results of crop-mix, machinery use, greenhouse gas (GHG) emissions per kg of crop product and energy use per hectare are in line with previous research and industry survey findings. Results show that the gross margin – energy trade-off is £36 GJ−1, representing the gross margin forgone by maximising net farm energy cf. maximising farm gross margin. The gross margin–GHG emission trade-off is £0.15 kg−1 CO2 eq, representing the gross margin forgone per kg of CO2 eq reduced when GHG emissions are minimised cf. maximising farm gross margin. The energy–GHG emission trade-off is 0.03 GJ kg−1 CO2 eq quantifying the reduction in net energy from the farm system per kg of CO2 eq reduced when minimising GHG emissions cf. maximising net farm energy. When both farm gross margin and net farm energy are maximised all the cereal straw is baled for sale. Sensitivity analysis of the model in relation to different prices of cereal straw shows that it becomes financially optimal to incorporate wheat straw at price of £11 t−1 for this co-product. Local market conditions for straw and farmer attitudes towards incorporation or sale of straw will impact on the straw price at which farmers will supply this potential bioenergy feedstock and represent important areas for future research. PMID:25540473

  9. Older smokers could be the strongest supporters for U.S. government regulation of tobacco: a focus group study

    PubMed Central

    2013-01-01

    Background Targeting of marginalized groups with aggressive tobacco marketing has been identified as exacerbating health disparities. However, interpretation of such targeting by groups varies, from surprise and outrage to regarding such marketing as evidence of social legitimacy. We sought to learn how an often-overlooked marginalized group, older adults, would respond to industry documents offering evidence of tobacco company target marketing. Methods We conducted 10 focus groups in California cities with older (≥50 years) smokers and former smokers. A set of previously-undisclosed tobacco industry documents related to target marketing was shown to the group in sequence. Audiotaped discussions were transcribed and data analyzed using qualitative approaches. Results Responses to evidence of tobacco industry targeting varied, with some regarding it as exploitive and others as normal business practice. However, in most groups, discussions turned to government’s failure to protect the public—even though government action /inaction was not prompted nor addressed in the discussion documents. Conclusion Given the Food and Drug Administration’s new authority to regulate tobacco products, these findings suggest that some of the tobacco industry’s “best customers” (older, established smokers and ex-smokers) may be strong supporters of government regulation of tobacco. PMID:23958397

  10. SU-E-T-605: RapidArc Combined with DIBH Technique for Thoracic Esophageal Carcinoma: The Potential Value of Target Immobilization and Reduced Lung Density in Dose Escalation.

    PubMed

    Yin, Y; Liu, T; Zhai, D

    2012-06-01

    To compare the dosimetric benefits of Rapidarc (RA) combined with deep inspiration breath-hold (DIBH) with those of other standard techniques, including free breathing (FB) during fixed-field intensity modulated radiation therapy (IMRT) and dual arc RA, in the treatment of patients with thoracic esophageal carcinoma (EC). Ten patients with EC underwent computed tomography (CT) scans under 2 respiration conditions: free-breathing (FB) and DIBH. These scans were used to generate 3-dimensional conformal treatment plans. For breath-hold scans, the patients were brought to reproducible respiration levels using active breathing control (ABC) maneuvers. Planning target volumes (PTVs) for FB plans included a 0.5 cm margin for setup plus a 1 cm margin equal to the extent of tumor motion for respiration. PTVs for DIBH plans included a 0.5 cm margin for setup error and a 0.5 cm margin for residual uncertainty in tumor position. Using a dose level of 60 Gy to the PTV, three treatment plans were generated: IMRT-FB, RA-FB and RA-ABC, and the target and normal tissue volumes were compared, as were the dosimetry parameters. On average, the DIBH technique resulted in increased lung volumes compared with FB techniques. There was no significant differences in gross tumor volume between the two breathing states (p > 0.05); but PTV and heart volume were larger for FB than for DIBH (p < 0.05). The overall CI and HI for the RA-ABC plan was slightly inferior to those of the IMRT- FB and RA-FB plans (p < 0.05 each). With DIBH, the heart was partly out of the beam portals and the average mean heart dose was reduced. Compared with conventional FB, RA combined with DIBH significantly reduced cardiac and pulmonary doses without compromising the target coverage and may reduce treatment toxicity, enabling dose escalation in future prospective studies of patients with EC. © 2012 American Association of Physicists in Medicine.

  11. "Resuscitation" of marginal liver allografts for transplantation with machine perfusion technology.

    PubMed

    Graham, Jay A; Guarrera, James V

    2014-08-01

    As the rate of medically suitable donors remains relatively static worldwide, clinicians have looked to novel methods to meet the ever-growing demand of the liver transplant waiting lists worldwide. Accordingly, the transplant community has explored many strategies to offset this deficit. Advances in technology that target the ex vivo "preservation" period may help increase the donor pool by augmenting the utilization and improving the outcomes of marginal livers. Novel ex vivo techniques such as hypothermic, normothermic, and subnormothermic machine perfusion may be useful to "resuscitate" marginal organs by reducing ischemia/reperfusion injury. Moreover, other preservation techniques such as oxygen persufflation are explored as they may also have a role in improving function of "marginal" liver allografts. Currently, marginal livers are frequently discarded or can relegate the patient to early allograft dysfunction and primary non-function. Bench to bedside advances are rapidly emerging and hold promise for expanding liver transplantation access and improving outcomes. Copyright © 2014 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  12. Assessment and quantification of patient set-up errors in nasopharyngeal cancer patients and their biological and dosimetric impact in terms of generalized equivalent uniform dose (gEUD), tumour control probability (TCP) and normal tissue complication probability (NTCP).

    PubMed

    Boughalia, A; Marcie, S; Fellah, M; Chami, S; Mekki, F

    2015-06-01

    The aim of this study is to assess and quantify patients' set-up errors using an electronic portal imaging device and to evaluate their dosimetric and biological impact in terms of generalized equivalent uniform dose (gEUD) on predictive models, such as the tumour control probability (TCP) and the normal tissue complication probability (NTCP). 20 patients treated for nasopharyngeal cancer were enrolled in the radiotherapy-oncology department of HCA. Systematic and random errors were quantified. The dosimetric and biological impact of these set-up errors on the target volume and the organ at risk (OARs) coverage were assessed using calculation of dose-volume histogram, gEUD, TCP and NTCP. For this purpose, an in-house software was developed and used. The standard deviations (1SDs) of the systematic set-up and random set-up errors were calculated for the lateral and subclavicular fields and gave the following results: ∑ = 0.63 ± (0.42) mm and σ = 3.75 ± (0.79) mm, respectively. Thus a planning organ at risk volume (PRV) margin of 3 mm was defined around the OARs, and a 5-mm margin used around the clinical target volume. The gEUD, TCP and NTCP calculations obtained with and without set-up errors have shown increased values for tumour, where ΔgEUD (tumour) = 1.94% Gy (p = 0.00721) and ΔTCP = 2.03%. The toxicity of OARs was quantified using gEUD and NTCP. The values of ΔgEUD (OARs) vary from 0.78% to 5.95% in the case of the brainstem and the optic chiasm, respectively. The corresponding ΔNTCP varies from 0.15% to 0.53%, respectively. The quantification of set-up errors has a dosimetric and biological impact on the tumour and on the OARs. The developed in-house software using the concept of gEUD, TCP and NTCP biological models has been successfully used in this study. It can be used also to optimize the treatment plan established for our patients. The gEUD, TCP and NTCP may be more suitable tools to assess the treatment plans before treating the patients.

  13. Intraoperative Evaluation of Breast Tumor Margins with Optical Coherence Tomography

    PubMed Central

    Nguyen, Freddy T.; Zysk, Adam M.; Chaney, Eric J.; Kotynek, Jan G.; Oliphant, Uretz J.; Bellafiore, Frank J.; Rowland, Kendrith M.; Johnson, Patricia A.; Boppart, Stephen A.

    2009-01-01

    As breast cancer screening rates increase, smaller and more numerous lesions are being identified earlier, leading to more breast-conserving surgical procedures. Achieving a clean surgical margin represents a technical challenge with important clinical implications. Optical coherence tomography (OCT) is introduced as an intraoperative high-resolution imaging technique that assesses surgical breast tumor margins by providing real-time microscopic images up to 2 mm beneath the tissue surface. In a study of 37 patients split between training and study groups, OCT images covering 1 cm2 regions were acquired from surgical margins of lumpectomy specimens, registered with ink, and correlated with corresponding histological sections. A 17 patient training set used to establish standard imaging protocols and OCT evaluation criteria demonstrated that areas of higher scattering tissue with a heterogeneous pattern were indicative of tumor cells and tumor tissue, in contrast to lower scattering adipocytes found in normal breast tissue. The remaining 20 patients were enrolled into the feasibility study. Of these lumpectomy specimens, 11 were identified with a positive or close surgical margin and 9 were identified with a negative margin under OCT. Based on histological findings, 9 true positives, 9 true negatives, 2 false positives, and 0 false negatives were found, yielding a sensitivity of 100% and specificity of 82%. These results demonstrate the potential of OCT as a real-time method for intraoperative margin assessment in breast conserving surgeries. PMID:19910294

  14. Incorporating latitudinal and central–marginal trends in assessing genetic variation across species ranges

    Treesearch

    Qinfeng Guo

    2012-01-01

    The genetic variation across a species’ range is an important factor in speciation and conservation, yet searching for general patterns and underlying causes remains challenging. While the majority of comparisons between central and marginal populations have revealed a general central–marginal (C-M) decline in genetic diversity, others show no clear pattern. Similarly...

  15. Using the Sampling Margin of Error to Assess the Interpretative Validity of Student Evaluations of Teaching

    ERIC Educational Resources Information Center

    James, David E.; Schraw, Gregory; Kuch, Fred

    2015-01-01

    We present an equation, derived from standard statistical theory, that can be used to estimate sampling margin of error for student evaluations of teaching (SETs). We use the equation to examine the effect of sample size, response rates and sample variability on the estimated sampling margin of error, and present results in four tables that allow…

  16. Real-Time Stability Margin Measurements for X-38 Robustness Analysis

    NASA Technical Reports Server (NTRS)

    Bosworth, John T.; Stachowiak, Susan J.

    2005-01-01

    A method has been developed for real-time stability margin measurement calculations. The method relies on a tailored-forced excitation targeted to a specific frequency range. Computation of the frequency response is matched to the specific frequencies contained in the excitation. A recursive Fourier transformation is used to make the method compatible with real-time calculation. The method was incorporated into the X-38 nonlinear simulation and applied to an X-38 robustness test. X-38 stability margins were calculated for different variations in aerodynamic and mass properties over the vehicle flight trajectory. The new method showed results comparable to more traditional stability analysis techniques, and at the same time, this new method provided coverage that is more complete and increased efficiency.

  17. Orientational preferences of neighboring helices can drive ER insertion of a marginally hydrophobic transmembrane helix

    PubMed Central

    Öjemalm, Karin; Halling, Katrin K.; Nilsson, IngMarie; von Heijne, Gunnar

    2013-01-01

    Summary α-helical integral membrane proteins critically depend on the correct insertion of their transmembrane α-helices into the lipid bilayer for proper folding, yet a surprisingly large fraction of the transmembrane α-helices in multispanning integral membrane proteins are not sufficiently hydrophobic to insert into the target membrane by themselves. How can such marginally hydrophobic segments nevertheless form transmembrane helices in the folded structure? Here, we show that a transmembrane helix with a strong orientational preference (Ncyt-Clum or Nlum-Ccyt) can both increase and decrease the hydrophobicity threshold for membrane insertion of a neighboring, marginally hydrophobic helix. This effect helps explain the ‘missing hydrophobicity’ in polytopic membrane proteins. PMID:22281052

  18. Impact of respiratory-correlated CT sorting algorithms on the choice of margin definition for free-breathing lung radiotherapy treatments.

    PubMed

    Thengumpallil, Sheeba; Germond, Jean-François; Bourhis, Jean; Bochud, François; Moeckli, Raphaël

    2016-06-01

    To investigate the impact of Toshiba phase- and amplitude-sorting algorithms on the margin strategies for free-breathing lung radiotherapy treatments in the presence of breathing variations. 4D CT of a sphere inside a dynamic thorax phantom was acquired. The 4D CT was reconstructed according to the phase- and amplitude-sorting algorithms. The phantom was moved by reproducing amplitude, frequency, and a mix of amplitude and frequency variations. Artefact analysis was performed for Mid-Ventilation and ITV-based strategies on the images reconstructed by phase- and amplitude-sorting algorithms. The target volume deviation was assessed by comparing the target volume acquired during irregular motion to the volume acquired during regular motion. The amplitude-sorting algorithm shows reduced artefacts for only amplitude variations while the phase-sorting algorithm for only frequency variations. For amplitude and frequency variations, both algorithms perform similarly. Most of the artefacts are blurring and incomplete structures. We found larger artefacts and volume differences for the Mid-Ventilation with respect to the ITV strategy, resulting in a higher relative difference of the surface distortion value which ranges between maximum 14.6% and minimum 4.1%. The amplitude- is superior to the phase-sorting algorithm in the reduction of motion artefacts for amplitude variations while phase-sorting for frequency variations. A proper choice of 4D CT sorting algorithm is important in order to reduce motion artefacts, especially if Mid-Ventilation strategy is used. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Comparison of intra-operative specimen mammography to standard specimen mammography for excision of non-palpable breast lesions: a randomized trial.

    PubMed

    Miller, Cynthia L; Coopey, Suzanne B; Rafferty, Elizabeth; Gadd, Michele; Smith, Barbara L; Specht, Michelle C

    2016-02-01

    Standard specimen mammography (SSM) is performed in the radiology department after wire-localized excision of non-palpable breast lesions to confirm the presence of the target and evaluate margins. Alternatively, intra-operative specimen mammography (ISM) allows surgeons to view images in the operating room (OR). We conducted a randomized study comparing ISM and SSM. Women undergoing wire-localized excision for breast malignancy or imaging abnormality were randomized to SSM or ISM. For SSM, the specimen was transported to the radiology department for imaging and interpretation. For ISM, the specimen was imaged in the OR for interpretation by the surgeon and sent for SSM. Interpretation time was from specimen leaving OR until radiologist interpretation for SSM and from placement in ISM device until surgeon interpretation for ISM. Procedure and interpretation times were compared. Concordance between ISM and SSM for target and margins was evaluated. 72 patients were randomized, 36 ISM and 36 SSM. Median procedure times were similar, 48.5 (17-138) min for ISM, and 54 (17-40) min for SSM (p = 0.72), likely since specimens in both groups traveled to radiology for SSM. Median interpretation time was significantly shorter with ISM, 1 (0.5-2.0) and 9 (4-16) min for ISM and SSM, respectively (p < 0.0001). Among specimens with ISM and SSM, concordance was 100 % (35/35) for target and 93 % (14/15) for margins. In this randomized trial, use of ISM compared with SSM significantly reduced interpretation times, while accurately identifying the target. This could result in decreased operative costs from shorter OR times with use of ISM.

  20. Enhancing the diversity of breeding invertebrates within field margins of intensively managed grassland: Effects of alternative management practices.

    PubMed

    Fritch, Rochelle A; Sheridan, Helen; Finn, John A; McCormack, Stephen; Ó hUallacháin, Daire

    2017-11-01

    Severe declines in biodiversity have been well documented for many taxonomic groups due to intensification of agricultural practices. Establishment and appropriate management of arable field margins can improve the diversity and abundance of invertebrate groups; however, there is much less research on field margins within grassland systems. Three grassland field margin treatments (fencing off the existing vegetation "fenced"; fencing with rotavation and natural regeneration "rotavated" and; fencing with rotavation and seeding "seeded") were compared to a grazed control in the adjacent intensively managed pasture. Invertebrates were sampled using emergence traps to investigate species breeding and overwintering within the margins. Using a manipulation experiment, we tested whether the removal of grazing pressure and nutrient inputs would increase the abundance and richness of breeding invertebrates within grassland field margins. We also tested whether field margin establishment treatments, with their different vegetation communities, would change the abundance and richness of breeding invertebrates in the field margins. Exclusion of grazing and nutrient inputs led to increased abundance and richness in nearly all invertebrate groups that we sampled. However, there were more complex effects of field margin establishment treatment on the abundance and richness of invertebrate taxa. Each of the three establishment treatments supported a distinct invertebrate community. The removal of grazing from grassland field margins provided a greater range of overwintering/breeding habitat for invertebrates. We demonstrate the capacity of field margin establishment to increase the abundance and richness in nearly all invertebrate groups in study plots that were located on previously more depauperate areas of intensively managed grassland. These results from grassland field margins provide evidence to support practical actions that can inform Greening (Pillar 1) and agri-environment measures (Pillar 2) of the Common Agricultural Policy (CAP). Before implementing specific management regimes, the conservation aims of agri-environment measures should be clarified by defining the target species or taxonomic groups.

  1. [Trends of cancer mortality rates in children and adolescents by level of marginalization in Mexico (1990-2009)].

    PubMed

    Escamilla-Santiago, Ricardo Antonio; Narro-Robles, José; Fajardo-Gutiérrez, Arturo; Rascón-Pacheco, Ramón Alberto; López-Cervantes, Malaquías

    2012-01-01

    To determine childhood and adolescent cancer mortality by the level of marginalization in Mexico. We used 1990-2009 death certificates estimating age-standardized rates. We calculated the Average Annual Percent Change (AAPC) using the Joinpoint Regression program available at the National Cancer Institute to assess tendency. Cancer mortality rates increased. AAPC were 0.87% male and 0.96% female children, and for adolescents were: males 1.22% and females 0.63%. The neoplasm pattern in infants was leukemia -central nervous system- lymphomas; and in adolescents it was leukemia -bone and articulation- lymphomas. The increase in cancer mortality corresponded to the high and highest marginated areas of each state. The increase in highly marginated areas may be partly explained by well-documented local registration of deaths. Further studies focusing on survival are required in order to better assess the effectiveness of cancer detection and medical treatment in our country.

  2. Gigapixel surface imaging of radical prostatectomy specimens for comprehensive detection of cancer-positive surgical margins using structured illumination microscopy

    PubMed Central

    Wang, Mei; Tulman, David B.; Sholl, Andrew B.; Kimbrell, Hillary Z.; Mandava, Sree H.; Elfer, Katherine N.; Luethy, Samuel; Maddox, Michael M.; Lai, Weil; Lee, Benjamin R.; Brown, J. Quincy

    2016-01-01

    Achieving cancer-free surgical margins in oncologic surgery is critical to reduce the need for additional adjuvant treatments and minimize tumor recurrence; however, there is a delicate balance between completeness of tumor removal and preservation of adjacent tissues critical for normal post-operative function. We sought to establish the feasibility of video-rate structured illumination microscopy (VR-SIM) of the intact removed tumor surface as a practical and non-destructive alternative to intra-operative frozen section pathology, using prostate cancer as an initial target. We present the first images of the intact human prostate surface obtained with pathologically-relevant contrast and subcellular detail, obtained in 24 radical prostatectomy specimens immediately after excision. We demonstrate that it is feasible to routinely image the full prostate circumference, generating gigapixel panorama images of the surface that are readily interpreted by pathologists. VR-SIM confirmed detection of positive surgical margins in 3 out of 4 prostates with pathology-confirmed adenocarcinoma at the circumferential surgical margin, and furthermore detected extensive residual cancer at the circumferential margin in a case post-operatively classified by histopathology as having negative surgical margins. Our results suggest that the increased surface coverage of VR-SIM could also provide added value for detection and characterization of positive surgical margins over traditional histopathology. PMID:27257084

  3. Under conditions of large geometric miss, tumor control probability can be higher for static gantry intensity-modulated radiation therapy compared to volume-modulated arc therapy for prostate cancer.

    PubMed

    Balderson, Michael; Brown, Derek; Johnson, Patricia; Kirkby, Charles

    2016-01-01

    The purpose of this work was to compare static gantry intensity-modulated radiation therapy (IMRT) with volume-modulated arc therapy (VMAT) in terms of tumor control probability (TCP) under scenarios involving large geometric misses, i.e., those beyond what are accounted for when margin expansion is determined. Using a planning approach typical for these treatments, a linear-quadratic-based model for TCP was used to compare mean TCP values for a population of patients who experiences a geometric miss (i.e., systematic and random shifts of the clinical target volume within the planning target dose distribution). A Monte Carlo approach was used to account for the different biological sensitivities of a population of patients. Interestingly, for errors consisting of coplanar systematic target volume offsets and three-dimensional random offsets, static gantry IMRT appears to offer an advantage over VMAT in that larger shift errors are tolerated for the same mean TCP. For example, under the conditions simulated, erroneous systematic shifts of 15mm directly between or directly into static gantry IMRT fields result in mean TCP values between 96% and 98%, whereas the same errors on VMAT plans result in mean TCP values between 45% and 74%. Random geometric shifts of the target volume were characterized using normal distributions in each Cartesian dimension. When the standard deviations were doubled from those values assumed in the derivation of the treatment margins, our model showed a 7% drop in mean TCP for the static gantry IMRT plans but a 20% drop in TCP for the VMAT plans. Although adding a margin for error to a clinical target volume is perhaps the best approach to account for expected geometric misses, this work suggests that static gantry IMRT may offer a treatment that is more tolerant to geometric miss errors than VMAT. Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  4. [Planning of esthetic oral rehabilitation according to correlative analysis of clinical and morphological features of the marginal gingiva].

    PubMed

    Stafeev, A A; Zinov'ev, G I; Drozdov, D D

    2015-01-01

    The orthopedic restoration and related to its clinical stages (preparation, gingival retraction, impression) is often associated with complications which arise from the marginal gingiva. The technology of indirect ceramic restoration requires an assessment of the clinical and morphological parameters of periodontal tissues. The study outlines correlation between the type of periodontal histhology and inflammatory and degenerative complications that has been established after the analysis of morphofunctional state of periodontal tissue. Results of clinical studies and correlation analysis of clinical and morphological parameters of marginal gingiva has shown that important parameter influencing the choice of manufacturing technology are the position of restoration margin relatively to marginal gingiva and periodontal morphotype.

  5. Development of a Model System to Evaluate Local Recurrence in Osteosarcoma and Assessment of the Effects of Bone Morphogenetic Protein-2.

    PubMed

    Geller, David S; Singh, Michael Y; Zhang, Wendong; Gill, Jonathan; Roth, Michael E; Kim, Mimi Y; Xie, Xianhong; Singh, Christopher K; Dorfman, Howard D; Villanueva-Siles, Esperanza; Park, Amy; Piperdi, Sajida; Gorlick, Richard

    2015-07-01

    It is increasingly relevant to better define what constitutes an adequate surgical margin in an effort to improve reconstructive longevity and functional outcomes following osteosarcoma surgery. In addition, nonunion remains a challenging problem in some patients following allograft reconstruction. Bone morphogenetic protein-2 (BMP-2) could enhance osseous union, but has been historically avoided due to concerns that it may promote tumor recurrence. An orthotopic xenograft murine model was utilized to describe the natural temporal course of osteosarcoma growth. Tumors were treated either with surgery alone, surgery and single-agent chemotherapy, or surgery and dual-agent chemotherapy to assess the relationship between surgical margin and local recurrence. The effect of BMP-2 on local recurrence was similarly assessed. Osteosarcoma tumor growth was categorized into reproducible phases. Margins greater than 997 μm resulted in local control following surgery alone. Margins greater than 36 μm resulted in local control following surgery and single-agent chemotherapy. Margins greater than 12 μm resulted in local control following surgery and dual-agent chemotherapy. The application of exogenous BMP-2 does not confer an increased risk of local recurrence. This model reliably reproduces the clinical, radiographic, and surgical conditions encountered in human osteosarcoma. It successfully incorporates relevant chemotherapy, further paralleling the human experience. Surgical margins required to achieve local control in osteosarcoma can be reduced using single-agent chemotherapy and further decreased using dual-agent chemotherapy. The application of BMP-2 does not increase local recurrence in this model. ©2014 American Association for Cancer Research.

  6. Essays on microgrids, asymmetric pricing and market power in electricity markets

    NASA Astrophysics Data System (ADS)

    Lo Prete, Chiara

    This dissertation presents four studies of the electricity industry. The first and second essays use economic-engineering models to assess different aspects of microgrid penetration in regional electricity markets, while the last two studies contain empirical analyses aimed at evaluating the performance of wholesale electricity markets. Chapter 2 develops a framework to quantify economic, environmental, efficiency and reliability impacts of different power production scenarios in a regional system, focusing on the interaction of microgrids with the existing transmission and distribution grid. The setting is the regional network formed by Belgium, France, Germany and the Netherlands. The study presents simulations of power market outcomes under various policies and levels of microgrid penetration, and evaluates them using a diverse set of metrics. Chapter 3 studies the interaction between a microgrid and a regulated electric utility in a regional electricity market. I consider the interaction among the utility, the microgrid developer and consumers in the framework of cooperative game theory (assuming exchangeable utility), and use regional market models to simulate scenarios in which microgrid introduction may or may not be socially beneficial. Under the assumptions of this chapter, customer participation is essential to the development of socially beneficial microgrids, while the utility has little or no gain from it. Discussed incentives to avoid that utilities block microgrid entry include additional revenue drivers related to microgrid connection, decoupling and performance-based mechanisms targeted at service quality. When prices are below marginal costs of utility provided power, microgrid development may be socially beneficial, but unprofitable for microgrid customers and its developer. By imposing lower charges and higher remuneration for its services, the regulator could ensure that microgrid value is positive, without adversely impacting the utility. Chapter 4 examines the possibility of asymmetric transmission of CO 2 and fuel prices to electricity futures prices in the second phase of the European Emission Trading Scheme. The goal is to assess whether output prices tend to respond more quickly to input price increases than decreases: this phenomenon is known as "rockets and feathers" in the literature. Results do not provide empirical evidence of statistically significant differences in the response of power prices to positive and negative shocks in CO 2 allowance and fuel markets. Chapter 5 re-examines the issue of the potential exercise of market power in California after liberalization, with a focus on its day-ahead energy market (the former PX) and its five largest thermal generators. The analysis focuses on a peak hour of operation (hour 18) and disregards hours in which congestion occurred. First, I define a direct measure of unilateral market power for each firm, equal to the hourly inverse elasticity of its residual demand function. The second part of the analysis aims at assessing whether the necessary conditions for the unilateral exercise of market power were satisfied in practice, based on a comparison of PX market-clearing prices, estimated marginal revenues and estimated bounds for the marginal costs of generation of each supplier. By conservatively assuming that the estimated upper bound is close to each firm's actual marginal cost of generation, the analysis suggests that in a large fraction of hours the thermal generators were acting less competitively that what implied by unilateral profit maximization. If instead I explicitly account for uncertainty in the marginal cost estimates with the introduction of a +/-10% margin on the estimated bounds, thermal generators are equally likely to bid close to their marginal costs or above them. Among the hours characterized by market-clearing prices above marginal costs, 64% present, on average, evidence of less competitive than Nash behavior. Two possible explanations for the observed restrained quantities, relative to the Nash level, include firms' coordinating efforts to raise prices on the day-ahead market and a Cournot game among the thermal generators, since the Cournot equilibrium represents an upper bound on supply function equilibria. (Abstract shortened by UMI.)

  7. A comparison of marginal fit between press-fabricated and CAD/CAM lithium disilicate crowns.

    PubMed

    Carlile, Richard S; Owens, Wade H; Greenwood, William J; Guevara, Peter H

    2018-01-01

    The purpose of this study was to compare the marginal fit of press-fabricated lithium disilicate crowns with that of computer-aided design/computer-aided manufacturing (CAD/CAM) lithium disilicate crowns to determine if the fabrication method has an influence on marginal fit. The marginal fit of 25 pressed and 25 CAD/CAM crowns was measured using the replica technique. The sites measured were the mesial, distal, facial, and lingual margins. A microscope at 10× magnification was used to obtain the measurements. Each site was measured 4 times, and intraclass correlation coefficients were used to assess measurement errors. An unpaired t test was used to evaluate the differences between the 2 groups. Mean marginal gap measurements were greater for CAD/CAM crowns than for pressed crowns at all sites. Only the difference in mean gap at the facial margin was statistically significant (P < 0.001). Press-fabricated lithium disilicate crowns provided a better marginal fit than those fabricated by CAD/CAM, but both fabrication methods provided crowns with a clinically acceptable marginal fit.

  8. Lateral view dissection of the prostato-urethral junction to reduce positive apical margin in laparoscopic radical prostatectomy.

    PubMed

    Sasaki, Hiroshi; Miki, Jun; Kimura, Takahiro; Sanuki, Kunitaro; Miki, Kenta; Takahashi, Hiroyuki; Egawa, Shin

    2009-08-01

    To assess the impact of lateral view apical dissection in laparoscopic radical prostatectomy (LRP) on the reduction of positive surgical margin rates and recovery of postoperative continence. One hundred and forty-four consecutive patients underwent LRP from October 2004 to March 2008. Lateral view dissection of the prostato-urethral junction was conducted in 76 of them (Group 2). Standard dissection was used in the remaining patients (Group 1). The effect of this technical modification on the reduction of positive surgical margin rates and postoperative recovery of urinary continence was assessed in the two groups. Overall, the incidence of positive margins decreased from 23 (35.9%) in Group 1 to 16 cases (21.9%) in Group 2 (P = 0.07). Positive margin rates in pT2 decreased from 30.6% to 6.5% (P = 0.006). Apical and dorso-apical margins were reduced from 26.5% to 4.3% (P = 0.009) and from 10.2% to 0% (P < 0.001), respectively. Postoperative recovery of urinary continence improved significantly, with a pad-free rate over the first 3 months of 55.9% in Group 1 vs 71.7% in Group 2 (P = 0.01). Multivariate logistic regression analysis showed this modified surgical technique to predict a lower rate of positive margins. Lateral view dissection of the prostato-urethral junction is an easily applicable technical modification. It provides better visualization of apical anatomy substantially contributing to the reduction of positive surgical margin rates, especially at the level of prostatic apex.

  9. Optimization of leaf margins for lung stereotactic body radiotherapy using a flattening filter-free beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wakai, Nobuhide, E-mail: wakai@naramed-u.ac.jp; Sumida, Iori; Otani, Yuki

    Purpose: The authors sought to determine the optimal collimator leaf margins which minimize normal tissue dose while achieving high conformity and to evaluate differences between the use of a flattening filter-free (FFF) beam and a flattening-filtered (FF) beam. Methods: Sixteen lung cancer patients scheduled for stereotactic body radiotherapy underwent treatment planning for a 7 MV FFF and a 6 MV FF beams to the planning target volume (PTV) with a range of leaf margins (−3 to 3 mm). Forty grays per four fractions were prescribed as a PTV D95. For PTV, the heterogeneity index (HI), conformity index, modified gradient indexmore » (GI), defined as the 50% isodose volume divided by target volume, maximum dose (Dmax), and mean dose (Dmean) were calculated. Mean lung dose (MLD), V20 Gy, and V5 Gy for the lung (defined as the volumes of lung receiving at least 20 and 5 Gy), mean heart dose, and Dmax to the spinal cord were measured as doses to organs at risk (OARs). Paired t-tests were used for statistical analysis. Results: HI was inversely related to changes in leaf margin. Conformity index and modified GI initially decreased as leaf margin width increased. After reaching a minimum, the two values then increased as leaf margin increased (“V” shape). The optimal leaf margins for conformity index and modified GI were −1.1 ± 0.3 mm (mean ± 1 SD) and −0.2 ± 0.9 mm, respectively, for 7 MV FFF compared to −1.0 ± 0.4 and −0.3 ± 0.9 mm, respectively, for 6 MV FF. Dmax and Dmean for 7 MV FFF were higher than those for 6 MV FF by 3.6% and 1.7%, respectively. There was a positive correlation between the ratios of HI, Dmax, and Dmean for 7 MV FFF to those for 6 MV FF and PTV size (R = 0.767, 0.809, and 0.643, respectively). The differences in MLD, V20 Gy, and V5 Gy for lung between FFF and FF beams were negligible. The optimal leaf margins for MLD, V20 Gy, and V5 Gy for lung were −0.9 ± 0.6, −1.1 ± 0.8, and −2.1 ± 1.2 mm, respectively, for 7 MV FFF compared to −0.9 ± 0.6, −1.1 ± 0.8, and −2.2 ± 1.3 mm, respectively, for 6 MV FF. With the heart inside the radiation field, the mean heart dose showed a V-shaped relationship with leaf margins. The optimal leaf margins were −1.0 ± 0.6 mm for both beams. Dmax to the spinal cord showed no clear trend for changes in leaf margin. Conclusions: The differences in doses to OARs between FFF and FF beams were negligible. Conformity index, modified GI, MLD, lung V20 Gy, lung V5 Gy, and mean heart dose showed a V-shaped relationship with leaf margins. There were no significant differences in optimal leaf margins to minimize these parameters between both FFF and FF beams. The authors’ results suggest that a leaf margin of −1 mm achieves high conformity and minimizes doses to OARs for both FFF and FF beams.« less

  10. Texas curve margin of safety.

    DOT National Transportation Integrated Search

    2013-01-01

    This software can be used to assist with the assessment of margin of safety for a horizontal curve. It is intended for use by engineers and technicians responsible for safety analysis or management of rural highway pavement or traffic control devices...

  11. 77 FR 41109 - Margin Requirements for Uncleared Swaps for Swap Dealers and Major Swap Participants

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-12

    ... and specifically requests quantitative data and analysis on the comparative costs and benefits of the... quantitative impact study (``QIS'') to assess the costs and benefits of margin requirements. The results of the...

  12. Marginal-cost contracting in the NHS: results of a preliminary survey.

    PubMed

    Beddow, A J; Cohen, D R

    2001-05-01

    Market disciplines and incentives were expected to improve efficiency in the UK National Health Service following the introduction of an 'internal market' in 1991. An exploratory survey of all Health Authorities and Trusts in the UK was undertaken to investigate whether players in the NHS managed market are behaving as economic theory predicts they should. The focus was on how and to what extent marginal costing has been used in the contracting process and on whether in some instances an inappropriate use of marginal costing may be resulting in inappropriate investment decisions. Twenty of 29 responding Health Authorities (69%) and 16 of 39 Trusts (41%) stated that they had considered purchasing/providing services on a marginal-cost basis and all of these led to contracts. Marginal-cost contracting appears to be fairly commonplace and the process does not appear to be causing insurmountable conflicts between players. Most marginal-cost contracts were specifically to meet waiting-list initiative targets. Overall results suggest that economic principles are not being particularly adhered to, with expansion in output rarely being related to available capacity. As increased responsibility for commissioning passes to primary care teams and local health groups, there are lessons for those involved in this more disaggregated approach to service shaping and service delivery.

  13. A Singular Perturbation Approach for Time-Domain Assessment of Phase Margin

    NASA Technical Reports Server (NTRS)

    Zhu, J. Jim; Yang, Xiaojing; Hodel, A Scottedward

    2010-01-01

    This paper considers the problem of time-domain assessment of the Phase Margin (PM) of a Single Input Single Output (SISO) Linear Time-Invariant (LTI) system using a singular perturbation approach, where a SISO LTI fast loop system, whose phase lag increases monotonically with frequency, is introduced into the loop as a singular perturbation with a singular perturbation (time-scale separation) parameter Epsilon. First, a bijective relationship between the Singular Perturbation Margin (SPM) max and the PM of the nominal (slow) system is established with an approximation error on the order of Epsilon(exp 2). In proving this result, relationships between the singular perturbation parameter Epsilon, PM of the perturbed system, PM and SPM of the nominal system, and the (monotonically increasing) phase of the fast system are also revealed. These results make it possible to assess the PM of the nominal system in the time-domain for SISO LTI systems using the SPM with a standardized testing system called "PM-gauge," as demonstrated by examples. PM is a widely used stability margin for LTI control system design and certification. Unfortunately, it is not applicable to Linear Time-Varying (LTV) and Nonlinear Time-Varying (NLTV) systems. The approach developed here can be used to establish a theoretical as well as practical metric of stability margin for LTV and NLTV systems using a standardized SPM that is backward compatible with PM.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yewondwossen, M; Robar, J; Parsons, D

    Purpose: During radiotherapy treatment, lung tumors can display substantial respiratory motion. This motion usually necessitates enlarged treatment margins to provide full tumour coverage. Unfortunately, these margins limit the dose that can be prescribed for tumour control and cause complications to normal tissue. Options for real-time methods of direct detection of tumour position, and particularly those that obviate the need for inserted fiducial markers, are limited. We propose a method of tumor tracking without implanted fiducial markers using a novel fast switching-target that toggles between a FFF copper/tungsten therapy mode and a FFF low-Z target mode for imaging. In this workmore » we demonstrate proof-of-concept of this new technology. Methods: The prototype includes two targets: i) a FFF copper/tungsten target equivalent to that in the Varian 2100 EX 6 MV, and ii) a low-Z (carbon) target with a thickness of 110% of continuous slowing down approximation range (CSDA) at 7 MeV. The two targets can be exchanged with a custom made linear slide and motor-driven actuator. The usefulness of the switching-target concept is demonstrated through experimental BEV Planar images acquired with continual treatment and imaging at a user-defined period. Results: The prototype switching-target demonstrates that two recent advances in linac technology (FFF target for therapy and low-Z target) can be combined with synergy. The switching-target approach offers the capacity for rapid switching between treatment and high-contrast imaging modes, allowing intrafractional tracking, as demonstrated in this work with dynamic breathing phantom. By using a single beam-line, the design is streamlined and may obviate the need for an auxiliary imaging system (e.g., kV OBI.) Conclusion: This switching-target approach is a feasible combination of two current advances in linac technology (FFF target for therapy and a FFF low-Z target) allowing new options in on-line IGRT.« less

  15. The impact of severe haemophilia and the presence of target joints on health-related quality-of-life.

    PubMed

    O'Hara, Jamie; Walsh, Shaun; Camp, Charlotte; Mazza, Giuseppe; Carroll, Liz; Hoxer, Christina; Wilkinson, Lars

    2018-05-02

    Joint damage remains a major complication associated with haemophilia and is widely accepted as one of the most debilitating symptoms for persons with severe haemophilia. The aim of this study is to describe how complications of haemophilia such as target joints influence health-related quality of life (HRQOL). Data on hemophilia patients without inhibitors were drawn from the 'Cost of Haemophilia across Europe - a Socioeconomic Survey' (CHESS) study, a cost-of-illness assessment in severe haemophilia A and B across five European countries (France, Germany, Italy, Spain, and the UK). Physicians provided clinical and sociodemographic information for 1285 adult patients, 551 of whom completed corresponding questionnaires, including EQ-5D. A generalised linear model was developed to investigate the relationship between EQ-5D index score and target joint status (defined in the CHESS study as areas of chronic synovitis), adjusted for patient covariates including socio-demographic characteristics and comorbidities. Five hundred and fifteen patients (42% of the sample) provided an EQ-5D response; a total of 692 target joints were recorded across the sample. Mean EQ-5D index score for patients with no target joints was 0.875 (standard deviation [SD] 0.179); for patients with one or more target joints, mean index score was 0.731 (SD 0.285). Compared to having no target joints, having one or more target joints was associated with lower index scores (average marginal effect (AME) -0.120; SD 0.0262; p < 0.000). This study found that the presence of chronic synovitis has a significant negative impact on HRQOL for adults with severe haemophilia. Prevention, early diagnosis and treatment of target joints should be an important consideration for clinicians and patients when managing haemophilia.

  16. SU-E-J-140: Availability of Using Diaphragm Matching in Stereotactic Body Radiotherapy (SBRT) at the Time in Breath-Holding SBRT for Liver Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kawahara, D; Tsuda, S.; Section of Radiation Therapy, Department of Clinical Support, Hiroshima University Hospital Health

    2014-06-01

    Purpose: IGRT based on the bone matching may produce a larger target positioning error in terms of the reproducibility of the expiration breath hold. Therefore, the feasibility of the 3D image matching between planning CT image and pretreatment CBCT image based on the diaphragm matching was investigated. Methods: In fifteen-nine liver SBRT cases, Lipiodol, uptake after TACE was outlined as the marker of the tumor. The relative coordinate of the isocenter obtained by the contrast matching was defined as the reference coordinate. The target positioning difference between diaphragm matching and bone matching were evaluated by the relative coordinate of themore » isocenter from the reference coordinate obtained by each matching technique. In addition, we evaluated PTV margins by van Herk setup margin formula. Results: The target positioning error by the diaphragm matching and the bone matching was 1.31±0.83 and 3.10±2.80 mm in the cranial-caudal(C-C) direction, 1.04±0.95 and 1.62±1.02 mm in the anterior-posterior(A-P) direction, 0.93±1.19 and 1.12±0.94 mm in the left-right(L-R) direction, respectively. The positioning error by the diaphragm matching was significantly smaller than the bone matching in the C-C direction (p<0.05). The setup margin of diaphragm matching and bone matching that we had calculated based on van Herk margin formula was 4.5mm and 6.2mm(C-C), and 3.6mm and 6.3mm(A-P), and 2.6mm and 4.5mm(L-R), respectively. Conclusion: IGRT based on a diaphragm matching could be one alternative image matching technique for the positioning of the patients with liver tumor.« less

  17. Postoperative Intensity-Modulated Radiotherapy for Squamous Cell Carcinoma of the External Auditory Canal and Middle Ear: Treatment Outcomes, Marginal Misses, and Perspective on Target Delineation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Wan-Yu; Kuo, Sung-Hsin; Graduate Institute of Clinical Medicine, National Taiwan University College of Medicine, Taipei, Taiwan

    Purpose: To report outcomes of the rare disease of squamous cell carcinoma (SCC) of the external auditory canal (EAC) and middle ear treated with surgery and postoperative intensity-modulated radiotherapy (IMRT). Failure patterns related to spatial dose distribution were also analyzed to provide insight into target delineation. Methods and Materials: A retrospective review was conducted of the records of 11 consecutive patients with SCC of the EAC and middle ear who were treated with curative surgery and postoperative IMRT at one institution between January 2007 and February 2010. The prescribed IMRT dose was 60 to 66 Gy at 2 Gy permore » fraction. Three patients also received concurrent cisplatin-based chemotherapy, and 1 patient received concurrent oral tegafur/uracil. The median follow-up time was 19 months (range, 6-33 months). Results: Four patients had locoregional recurrence, yielding an estimated 2-year locoregional control rate of 70.7%. Among them, 1 patient had persistent disease after treatment, and 3 had marginal recurrence. Distant metastasis occurred in 1 patient after extensive locoregional recurrence, yielding an estimated 2-year distant control rate of 85.7%. The estimated 2-year overall survival was 67.5%. The three cases of marginal recurrence were near the preauricular space and glenoid fossa of the temporomandibular joint, adjacent to the apex of the ear canal and glenoid fossa of the temporomandibular joint, and in the postauricular subcutaneous area and ipsilateral parotid nodes, respectively. Conclusions: Marginal misses should be recognized to improve target delineation. When treating SCC of the EAC and middle ear, care should be taken to cover the glenoid fossa of the temporomandibular joint and periauricular soft tissue. Elective ipsilateral parotid irradiation should be considered. The treatment planning procedure should also be refined to balance subcutaneous soft-tissue dosimetry and toxicity.« less

  18. TH-A-19A-06: Site-Specific Comparison of Analytical and Monte Carlo Based Dose Calculations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schuemann, J; Grassberger, C; Paganetti, H

    2014-06-15

    Purpose: To investigate the impact of complex patient geometries on the capability of analytical dose calculation algorithms to accurately predict dose distributions and to verify currently used uncertainty margins in proton therapy. Methods: Dose distributions predicted by an analytical pencilbeam algorithm were compared with Monte Carlo simulations (MCS) using TOPAS. 79 complete patient treatment plans were investigated for 7 disease sites (liver, prostate, breast, medulloblastoma spine and whole brain, lung and head and neck). A total of 508 individual passively scattered treatment fields were analyzed for field specific properties. Comparisons based on target coverage indices (EUD, D95, D90 and D50)more » were performed. Range differences were estimated for the distal position of the 90% dose level (R90) and the 50% dose level (R50). Two-dimensional distal dose surfaces were calculated and the root mean square differences (RMSD), average range difference (ARD) and average distal dose degradation (ADD), the distance between the distal position of the 80% and 20% dose levels (R80- R20), were analyzed. Results: We found target coverage indices calculated by TOPAS to generally be around 1–2% lower than predicted by the analytical algorithm. Differences in R90 predicted by TOPAS and the planning system can be larger than currently applied range margins in proton therapy for small regions distal to the target volume. We estimate new site-specific range margins (R90) for analytical dose calculations considering total range uncertainties and uncertainties from dose calculation alone based on the RMSD. Our results demonstrate that a reduction of currently used uncertainty margins is feasible for liver, prostate and whole brain fields even without introducing MC dose calculations. Conclusion: Analytical dose calculation algorithms predict dose distributions within clinical limits for more homogeneous patients sites (liver, prostate, whole brain). However, we recommend treatment plan verification using Monte Carlo simulations for patients with complex geometries.« less

  19. Postoperative intensity-modulated radiotherapy for squamous cell carcinoma of the external auditory canal and middle ear: treatment outcomes, marginal misses, and perspective on target delineation.

    PubMed

    Chen, Wan-Yu; Kuo, Sung-Hsin; Chen, Yu-Hsuan; Lu, Szu-Huai; Tsai, Chiao-Ling; Cheng, Jason Chia-Hsien; Hong, Ruey-Long; Chen, Ya-Fang; Hsu, Chuan-Jen; Lin, Kai-Nan; Ko, Jenq-Yuh; Lou, Pei-Jen; Wang, Cheng-Ping; Chong, Fok-Ching; Wang, Chun-Wei

    2012-03-15

    To report outcomes of the rare disease of squamous cell carcinoma (SCC) of the external auditory canal (EAC) and middle ear treated with surgery and postoperative intensity-modulated radiotherapy (IMRT). Failure patterns related to spatial dose distribution were also analyzed to provide insight into target delineation. A retrospective review was conducted of the records of 11 consecutive patients with SCC of the EAC and middle ear who were treated with curative surgery and postoperative IMRT at one institution between January 2007 and February 2010. The prescribed IMRT dose was 60 to 66 Gy at 2 Gy per fraction. Three patients also received concurrent cisplatin-based chemotherapy, and 1 patient received concurrent oral tegafur/uracil. The median follow-up time was 19 months (range, 6-33 months). Four patients had locoregional recurrence, yielding an estimated 2-year locoregional control rate of 70.7%. Among them, 1 patient had persistent disease after treatment, and 3 had marginal recurrence. Distant metastasis occurred in 1 patient after extensive locoregional recurrence, yielding an estimated 2-year distant control rate of 85.7%. The estimated 2-year overall survival was 67.5%. The three cases of marginal recurrence were near the preauricular space and glenoid fossa of the temporomandibular joint, adjacent to the apex of the ear canal and glenoid fossa of the temporomandibular joint, and in the postauricular subcutaneous area and ipsilateral parotid nodes, respectively. Marginal misses should be recognized to improve target delineation. When treating SCC of the EAC and middle ear, care should be taken to cover the glenoid fossa of the temporomandibular joint and periauricular soft tissue. Elective ipsilateral parotid irradiation should be considered. The treatment planning procedure should also be refined to balance subcutaneous soft-tissue dosimetry and toxicity. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Individualized Margins in 3D Conformal Radiotherapy Planning for Lung Cancer: Analysis of Physiological Movements and Their Dosimetric Impacts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Germain, Francois; Beaulieu, Luc; Fortin, Andre

    2008-04-01

    In conformal radiotherapy planning for lung cancer, respiratory movements are not taken into account when a single computed tomography (CT) scan is performed. This study examines tumor movements to design individualized margins to account for these movements and evaluates their dosimetric impacts on planning volume. Fifteen patients undergoing CT-based planning for radical radiotherapy for localized lung cancer formed the study cohort. A reference plan was constructed based on reference gross, clinical, and planning target volumes (rGTV, rCTV, and rPTV, respectively). The reference plans were compared with individualized plans using individualized margins obtained by using 5 serial CT scans to generatemore » individualized target volumes (iGTV, iCTV, and iPTV). Three-dimensional conformal radiation therapy was used for plan generation using 6- and 23-MV photon beams. Ten plans for each patient were generated and dose-volume histograms (DVHs) were calculated. Comparisons of volumetric and dosimetric parameters were performed using paired Student t-tests. Relative to the rGTV, the total volume occupied by the superimposed GTVs increased progressively with each additional CT scans. With the use of all 5 scans, the average increase in GTV was 52.1%. For the plans with closest dosimetric coverage, target volume was smaller (iPTV/rPTV ratio 0.808) but lung irradiation was only slightly decreased. Reduction in the proportion of lung tissue that received 20 Gy or more outside the PTV (V20) was observed both for 6-MV plans (-0.73%) and 23-MV plans (-0.65%), with p = 0.02 and p = 0.04, respectively. In conformal RT planning for the treatment of lung cancer, the use of serial CT scans to evaluate respiratory motion and to generate individualized margins to account for these motions produced only a limited lung sparing advantage.« less

  1. Patterns of Failure in Pediatric Rhabdomyosarcoma After Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vern-Gross, Tamara Z.; Indelicato, Daniel J., E-mail: dindelicato@floridaproton.org; Bradley, Julie A.

    Purpose: To report on the patterns of failure in children with rhabdomyosarcoma treated with proton therapy. Patients and Methods: Between February 2007 and November 2013, 66 children with a median age of 4.1 years (range, 0.6-15.3 years) diagnosed with nonmetastatic rhabdomyosarcoma were treated with proton therapy. Clinical target volume 1 was defined as the prechemotherapy tumor plus a 1-cm anatomically constrained margin. Clinical target volume 2 was defined as the postchemotherapy tumor (or tumor bed) plus a 0.5-cm anatomically constrained margin, further expanded to encompass potential pathways of spread, including soft tissue infiltrated with tumor at diagnosis. Results: Of the 66 children,more » 11 developed locally progressive disease at a median of 16 months (range, 14-32 months), for an actuarial 2-year local control rate of 88%. Among the children who progressed, median age and tumor size at diagnosis were 6.7 years (range, 0.6-16 years) and 6 cm (range, 2-8 cm), respectively. Of the recurrences, 64% and 36% were embryonal and alveolar, respectively. Disease progression was observed in 7 (64%) parameningeal, 2 (18%) head and neck (other), and 2 (18%) bladder/prostate subsites. At diagnosis, 8 of 11 patients who developed a recurrence were Intergroup Rhabdomyosarcoma Study stage 3, and all 11 were group III. Of the relapses, 100% (11 of 11) were confirmed as in-field within the composite 95% isodose line. One of the 11 patients (9%) developed a new simultaneous regional nodal recurrence outside of the previously treated radiation field. Conclusion: Early data suggest that the sharp dosimetric gradient associated with proton therapy is not associated with an increased risk of marginal failure. Routine use of a 0.5- to 1-cm clinical target volume 1/2 margin with highly conformal proton therapy does not compromise local control in children diagnosed with rhabdomyosarcoma with unfavorable risk features.« less

  2. Seismic margin assessment of the Edwin I. Hatch Nuclear Plant, Unit 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barr, W.T.; Moore, D.P.; Smith, J.E.

    1991-06-01

    This summary presents the results and lessons learned from the seismic margin assessment (SMA) of Unit 1 of the Hatch Nuclear Plant. The primary purpose of this SMA was to assess the practicality of the EPRI SMA methodology on a BWR on a soil site such as Hatch. The major findings from the Hatch SMA are briefly described along with the lessons learned during the project implementation. The experience gained on the Hatch SMA is expected to benefit others in the performance of future SMAs. 12 refs.

  3. Identifying Gaps in the Performance of Pediatric Trainees Who Receive Marginal/Unsatisfactory Ratings.

    PubMed

    Li, Su-Ting T; Tancredi, Daniel J; Schwartz, Alan; Guillot, Ann; Burke, Ann; Trimm, R Franklin; Guralnick, Susan; Mahan, John D; Gifford, Kimberly A

    2018-01-01

    To perform a derivation study to determine in which subcompetencies marginal/unsatisfactory pediatric residents had the greatest deficits compared with their satisfactorily performing peers and which subcompetencies best discriminated between marginal/unsatisfactory and satisfactorily performing residents. Multi-institutional cohort study of all 21 milestones (rated on four or five levels) reported to the Accreditation Council for Graduate Medical Education, and global marginal/unsatisfactory versus satisfactory performance reported to the American Board of Pediatrics. Data were gathered in 2013-2014. For each level of training (postgraduate year [PGY] 1, 2, and 3), mean differences between milestone levels of residents with marginal/unsatisfactory and satisfactory performance adjusted for clustering by program and C-statistics (area under receiver operating characteristic curve) were calculated. A Bonferroni-corrected significance threshold of .0007963 was used to account for multiple comparisons. Milestone and overall performance evaluations for 1,704 pediatric residents in 41 programs were obtained. For PGY1s, two subcompetencies had almost a one-point difference in milestone levels between marginal/unsatisfactory and satisfactory trainees and outstanding discrimination (≥ 0.90): organize/prioritize (0.93; C-statistic: 0.91) and transfer of care (0.97; C-statistic: 0.90). The largest difference between marginal/unsatisfactory and satisfactory PGY2s was trustworthiness (0.78). The largest differences between marginal/unsatisfactory and satisfactory PGY3s were ethical behavior (1.17), incorporating feedback (1.03), and professionalization (0.96). For PGY2s and PGY3s, no subcompetencies had outstanding discrimination. Marginal/unsatisfactory pediatric residents had different subcompetency gaps at different training levels. While PGY1s may have global deficits, senior residents may have different performance deficiencies requiring individualized counseling and targeted performance improvement plans.

  4. Chapter 34: Geology and petroleum potential of the rifted margins of the Canada Basin

    USGS Publications Warehouse

    Houseknecht, D.W.; Bird, K.J.

    2011-01-01

    Three sides of the Canada Basin are bordered by high-standing, conjugate rift shoulders of the Chukchi Borderland, Alaska and Canada. The Alaska and Canada margins are mantled with thick, growth-faulted sediment prisms, and the Chukchi Borderland contains only a thin veneer of sediment. The rift-margin strata of Alaska and Canada reflect the tectonics and sediment dispersal systems of adjacent continental regions whereas the Chukchi Borderland was tectonically isolated from these sediment dispersal systems. Along the eastern Alaska-southern Canada margin, termed herein the 'Canning-Mackenzie deformed margin', the rifted margin is deformed by ongoing Brooks Range tectonism. Additional contractional structures occur in a gravity fold belt that may be present along the entire Alaska and Canada margins of the Canada Basin. Source-rock data inboard of the rift shoulders and regional palaeogeographic reconstructions suggest three potential source-rock intervals: Lower Cretaceous (Hauterivian-Albian), Upper Cretaceous (mostly Turonian) and Lower Palaeogene. Burial history modelling indicates favourable timing for generation from all three intervals beneath the Alaska and Canada passive margins, and an active petroleum system has been documented in the Canning-Mackenzie deformed margin. Assessment of undiscovered petroleum resources indicates the greatest potential in the Canning-Mackenzie deformed margin and significant potential in the Canada and Alaska passive margins. ?? 2011 The Geological Society of London.

  5. Design definition study of a life/cruise fan technology V/STOL aircraft. Volume 2, addendum 2: Program risk assessment

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The results are presented of a risk assessment study conducted on two technology aircraft. The aircraft system components were reviewed and assessed for risk based on: (1) complexity relative to state-of-the-art, (2) manufacturing and qualification testing, (3) availability and delays, and (4) cost/schedule impact. These assessments were based on five risk nomenclatures: low, minor, moderate, high, and extreme. Each aircraft system was assigned an overall risk rating depending upon its contribution to the capability of the aircraft to achieve the performance goals. The slightly lower Sabreliner performance margin is due to the restricted flight envelope, the fixed landing gear, and internal fuel capacity. The Sabreliner with retractable gear and allowed to fly at its best speed and altitude would reflect performance margins similar to the New Airframe. These significant margins, inherent with the MCAIR three gas generator/three fan propulsion system, are major modifiers to risk assessment of both aircraft. The estimated risk and the associated key system and performance areas are tabulated.

  6. Exploring the Margin Recipe for Online Adaptive Radiation Therapy for Intermediate-Risk Prostate Cancer: An Intrafractional Seminal Vesicles Motion Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheng, Yang, E-mail: Yang.Sheng@duke.edu; Medical Physics Graduate Program, Duke University, Durham, North Carolina; Li, Taoran

    Purpose: To provide a benchmark for seminal vesicle (SV) margin selection to account for intrafractional motion and to investigate the effectiveness of 2 motion surrogates in predicting intrafractional SV coverage. Methods and Materials: Fifteen prostate patients were studied. Each patient had 5 pairs (1 patient had 4 pairs) of pretreatment and posttreatment cone beam CTs (CBCTs). Each pair of CBCTs was registered on the basis of prostate fiducial markers. All pretreatment SVs were expanded with 1-, 2-, 3-, 4-, 5-, and 8-mm isotropic margins to form a series of planning target volumes, and their intrafractional coverage to the posttreatment SVmore » determined the “ground truth” for exact coverage. Two motion surrogates, the center of mass (COM) and the border of contour, were evaluated by the use of Pearson product-moment correlation coefficient and exponential fitting for predicting SV underdosage. Action threshold of each surrogate was calculated. The margin for each surrogate was calculated according to a traditional margin recipe. Results: Ninety-five percent posttreatment SV coverage was achieved in 9%, 53%, 73%, 86%, 95%, and 97% of fractions with 1-, 2-, 3-, 4-, 5-, and 8-mm margins, respectively. The 5-mm margins provided 95% intrafractional SV coverage in over 90% of fractions. The correlation between the COM and border was weak, moderate, and strong in the left-right (L-R), anterior-posterior (A-P), and superior-inferior (S-I) directions, respectively. Exponential fitting gave the underdosage threshold of 4.5 and 7.0 mm for the COM and border. The Van Herk margin recipe recommended 0-, 0.5-, and 0.8-mm margins in the L-R, A-P, and S-I directions based on the COM, and 1.2-, 3.9-, and 2.5-mm margins based on the border. Conclusions: Five-millimeter isotropic margins for the SV constitute the minimum required to mitigate the intrafractional motion. Both the COM and the border are acceptable predictors for SV underdosage with 4.5- and 7.0-mm action threshold. Traditional margin based on the COM or border underestimates the margin.« less

  7. Aerial Reconnaissance Binoculars

    DTIC Science & Technology

    1974-06-01

    199212 Z= 8,51005 L= 0 M= 204139-4 N= . Table 1.2 Marginal ray height for zero degroos Ineldont rayo YO= .6 X ) Y= .60795 Z= 3-96631E-p X 0 Y= .6143...in high vibration environments where standard military binoculars (7 x 50) are only marginally helpful to the naked eye in the detection of targets...of-view 17.8 degrees Exit Pupil 9.65 mm Eye Relief 274 mm Size 4.5 x 8.75 x 3.5 inches Weight 4.3 lbs 3 2. Computer Design - Ray Tracing of Original

  8. Changes in behavior and salivary cortisol after targeted cognitive training in typical 12-month-old infants.

    PubMed

    Wass, Sam V; Cook, Clare; Clackson, Kaili

    2017-05-01

    Previous research has suggested that early development may be an optimal period to implement cognitive training interventions, particularly those relating to attention control, a basic ability that is essential for the development of other cognitive skills. In the present study, we administered gaze-contingent training (95 min across 2 weeks) targeted at voluntary attention control to a cohort of typical 12-month-old children (N = 24) and sham training to a control group (N = 24). We assessed training effects on (a) tasks involving nontrained aspects of attention control: visual sustained attention, habituation speed, visual recognition memory, sequence learning, and reversal learning; (b) general attentiveness (on-task behaviors during testing); and (c) salivary cortisol levels. Assessments were administered immediately after the cessation of training and at a 6-week follow-up. On the immediate posttest infants showed significantly more sustained visual attention, faster habituation, and improved sequence learning. Significant effects were also found for increased general attentiveness and decreased salivary cortisol. Some of these effects were still evident at the 6-week follow-up (significantly improved sequence learning and marginally improved sustained attention). These findings extend the emerging literature showing that attention training is possible in infancy. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  9. Stability Metrics for Simulation and Flight-Software Assessment and Monitoring of Adaptive Control Assist Compensators

    NASA Technical Reports Server (NTRS)

    Hodel, A. S.; Whorton, Mark; Zhu, J. Jim

    2008-01-01

    Due to a need for improved reliability and performance in aerospace systems, there is increased interest in the use of adaptive control or other nonlinear, time-varying control designs in aerospace vehicles. While such techniques are built on Lyapunov stability theory, they lack an accompanying set of metrics for the assessment of stability margins such as the classical gain and phase margins used in linear time-invariant systems. Such metrics must both be physically meaningful and permit the user to draw conclusions in a straightforward fashion. We present in this paper a roadmap to the development of metrics appropriate to nonlinear, time-varying systems. We also present two case studies in which frozen-time gain and phase margins incorrectly predict stability or instability. We then present a multi-resolution analysis approach that permits on-line real-time stability assessment of nonlinear systems.

  10. CBCT-guided evolutive library for cervical adaptive IMRT.

    PubMed

    Rigaud, Bastien; Simon, Antoine; Gobeli, Maxime; Lafond, Caroline; Leseur, Julie; Barateau, Anais; Jaksic, Nicolas; Castelli, Joël; Williaume, Danièle; Haigron, Pascal; De Crevoisier, Renaud

    2018-04-01

    In the context of adaptive radiation therapy (ART) for locally advanced cervical carcinoma (LACC), this study proposed an original cone-beam computed tomography (CBCT)-guided "Evolutive library" and evaluated it against four other known radiotherapy (RT) strategies. For 20 patients who underwent intensity-modulated radiation therapy (IMRT) for LACC, three planning CTs [with empty (EB), intermediate (IB), and full (FB) bladder volumes], a CT scan at 20 Gy and bi-weekly CBCTs for 5 weeks were performed. Five RT strategies were simulated for each patient: "Standard RT" was based on one IB planning CT; "internal target volume (ITV)-based RT" was an ITV built from the three planning CTs; "RT with one mid-treatment replanning (MidTtReplan)" corresponded to the standard RT with a replanning at 20 Gy; "Pretreatment library ART" using a planning library based on the three planning CTs; and the "Evolutive library ART", which was the "Pretreatment library ART" strategy enriched by including some CBCT anatomies into the library when the daily clinical target volume (CTV) shape differed from the ones in the library. Two planning target volume (PTV) margins of 7 and 10 mm were evaluated. All the strategies were geometrically compared in terms of the percentage of coverage by the PTV, for the CTV and the organs at risk (OAR) delineated on the CBCT. Inadequate coverage of the CTV and OARs by the PTV was also assessed using deformable image registration. The cumulated dose distributions of each strategy were likewise estimated and compared for one patient. The "Evolutive library ART" strategy involved a number of added CBCTs: 0 for 55%; 1 for 30%; 2 for 5%; and 3 for 10% of patients. Compared with the other four, this strategy provided the highest CTV geometric coverage by the PTV, with a mean (min-max) coverage of 98.5% (96.4-100) for 10 mm margins and 96.2% (93.0-99.7) for 7 mm margins (P < 0.05). Moreover, this strategy significantly decreased the geometric coverage of the bowel. CTV undercoverage by PTV occurred in the anterior and superior uterine regions for all strategies. The dosimetric analysis at 7 mm similarly demonstrated that the "Evolutive library ART" increased the V 42.75Gy of the CTV by 27%, 20%, 13%, and 28% compared with "Standard RT", "ITV-based RT", "MidTtReplan", and "Pretreatment library ART", respectively. The dose to the bowel was also decreased by the "Evolutive library ART" compared with that by the other strategies. The "Evolutive library ART" is a personalized ART strategy that comprises a pretreatment planning library of three CT scans, enriched for half of the patients by one to three per-treatment CBCTs. This original strategy increased both the CTV coverage and bowel sparing compared with all the other tested strategies and enables us to consider a PTV margin reduction. © 2018 American Association of Physicists in Medicine.

  11. Using Cold-water Coral Mini-mounds as Analogue for Giant Mound Growth: Assessment of Environmental Drivers and Anthropogenic Impact

    NASA Astrophysics Data System (ADS)

    Collart, T.; Stewart, H. A.; Howell, K.; Bourillet, J. F.; Llave, E.; Blamart, D.; Mienis, F.; Van Rooij, D.

    2015-12-01

    Cold-water coral (CWC) reefs are formed by framework building scleratinians Lophelia pertusa and Madrepora oculata that baffle sediment and over time, have the potential to develop into large coral mounds of up to 300m high (e.g. Belgica Mound Province). The detailed mechanisms of initiation and build-up of such large CWC mounds are however not yet fully understood. It is therefore essential to study smaller mounds (often termed "mini-mounds") that can be interpreted as earlier growth stages that haven't had the time to coalesce and develop into larger mounds. The FWO Minimound project (2013-2017) aims to investigate CWC mini-mounds within the Bay of Biscay (European Margin) in order to determine the impact of: (1) palaeoceanographic changes related to glacial-interglacial climate change in the last 15 ka, (2) hydrocarbon seepage processes and (3) anthropogenic fishing activities on CWC habitats. The project targets three minimound provinces: the Ferrol Canyon (Cantabrian Margin), the Guilvinec Canyon (Armorican Margin) and the Explorer and Dangeard Canyons (Celtic Margin). These mini-mounds are fossil and occur at relative shallow depths on the interface between the Eastern North Atlantic Central Water (ENACW) and the Mediterranean Outflow Water (MOW). Contrastingly, most living CWC reefs in this region of the Atlantic, dwell in the deeper MOW depth range, relying on the density and dynamics of this water mass for their food supply. In order to investigate the initiation, growth and demise of CWC mini-mounds, 35m of USBL guided sediment cores were retrieved from the Explorer and Dangeard Interfluves. We present data of sedimentological, geochemical and palaeoceanographic analyses throughout the cores, coupled with high-resolution geophysical data. Preliminary results indicate that the mound base is associated with a strong shift in sedimentation regime potentially linked to climate driven palaeoceanographic changes of the MOW-ENACW interface.

  12. Lithosphere structure and subsidence evolution of the conjugate S-African and Argentine margins

    NASA Astrophysics Data System (ADS)

    Dressel, Ingo; Scheck-Wenderoth, Magdalena; Cacace, Mauro; Götze, Hans-Jürgen; Franke, Dieter

    2016-04-01

    The bathymetric evolution of the South Atlantic passive continental margins is a matter of debate. Though it is commonly accepted that passive margins experience thermal subsidence as a result of lithospheric cooling as well as load induced subsidence in response to sediment deposition it is disputed if the South Atlantic passive margins were affected by additional processes affecting the subsidence history after continental breakup. We present a subsidence analysis along the SW African margin and offshore Argentina and restore paleobathymetries to assess the subsidence evolution of the margin. These results are discussed with respect to mechanisms behind margin evolution. Therefore, we use available information about the lithosphere-scale present-day structural configuration of these margins as a starting point for the subsidence analysis. A multi 1D backward modelling method is applied to separate individual subsidence components such as the thermal- as well as the load induced subsidence and to restore paleobathymetries for the conjugate margins. The comparison of the restored paleobathymetries shows that the conjugate margins evolve differently: Continuous subsidence is obtained offshore Argentina whereas the subsidence history of the SW African margin is interrupted by phases of uplift. This differing results for both margins correlate also with different structural configurations of the subcrustal mantle. In the light of these results we discuss possible implications for uplift mechanisms.

  13. Tissue preservation with mass spectroscopic analysis: Implications for cancer diagnostics.

    PubMed

    Hall, O Morgan; Peer, Cody J; Figg, William D

    2018-05-17

    Surgical intervention is a common treatment modality for localized cancer. Post-operative analysis involves evaluation of surgical margins to assess whether all malignant tissue has been resected because positive surgical margins lead to a greater likelihood of recurrence. Secondary treatments are utilized to minimize the negative effects of positive surgical margins. Recently, in Science Translational Medicine, Zhang et al describe a new mass spectroscopic technique that could potentially decrease the likelihood of positive surgical margins. Their nondestructive in vivo tissue sampling leads to a highly accurate and rapid cancer diagnosis with great precision between healthy and malignant tissue. This new tool has the potential to improve surgical margins and accelerate cancer diagnostics by analyzing biomolecular signatures of various tissues and diseases.

  14. Chapter 48: Geology and petroleum potential of the Eurasia Basin

    USGS Publications Warehouse

    Moore, Thomas E.; Pitman, Janet K.

    2011-01-01

    The Eurasia Basin petroleum province comprises the younger, eastern half of the Arctic Ocean, including the Cenozoic Eurasia Basin and the outboard part of the continental margin of northern Europe. For the USGS petroleum assessment (CARA), it was divided into four assessment units (AUs): the Lena Prodelta AU, consisting of the deep-marine part of the Lena Delta; the Nansen Basin Margin AU, comprising the passive margin sequence of the Eurasian plate; and the Amundsen Basin and Nansen Basin AUs which encompass the abyssal plains north and south of the Gakkel Ridge spreading centre, respectively. The primary petroleum system thought to be present is sourced in c. 50–44 Ma (Early to Middle Eocene) condensed pelagic deposits that could be widespread in the province. Mean estimates of undiscovered, technically recoverable petroleum resources include <1 billion barrels of oil (BBO) and about 1.4 trillion cubic feet (TCF) of nonassociated gas in Lena Prodelta AU, and <0.4 BBO and 3.4 TCF nonassociated gas in the Nansen Basin Margin AU. The Nansen Basin and Amundsen Basin AUs were not quantitatively assessed because they have less than 10% probability of containing at least one accumulation of 50 MMBOE (million barrels of oil equivalent).

  15. Meta-Analysis of Correlations Between Marginal Bone Resorption and High Insertion Torque of Dental Implants.

    PubMed

    Li, Haoyan; Liang, Yongqiang; Zheng, Qiang

    2015-01-01

    To evaluate correlations between marginal bone resorption and high insertion torque value (> 50 Ncm) of dental implants and to assess the significance of immediate and early/conventional loading of implants under a certain range torque value. Specific inclusion and exclusion criteria were used to retrieve eligible articles from Ovid, PubMed, and EBSCO up to December 2013. Screening of eligible studies, quality assessment, and data extraction were conducted in duplicate. The results were expressed as random/fixed-effects models using weighted mean differences for continuous outcomes with 95% confidence intervals. Initially, 154 articles were selected (11 from Ovid, 112 from PubMed, and 31 from EBSCO). After exclusion of duplicate articles and articles that did not meet the inclusion criteria, six clinical studies were selected. Assessment of P values revealed that correlations between marginal bone resorption and high insertion torque were not statistically significant and that there was no difference between immediately versus early/conventionally loaded implants under a certain range of torque. None of the meta-analyses revealed any statistically significant differences between high insertion torque and conventional insertion torque in terms of effects on marginal bone resorption.

  16. WSEAT Shock Testing Margin Assessment Using Energy Spectra Final Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sisemore, Carl; Babuska, Vit; Booher, Jason

    Several programs at Sandia National Laboratories have adopted energy spectra as a metric to relate the severity of mechanical insults to structural capacity. The purpose being to gain insight into the system's capability, reliability, and to quantify the ultimate margin between the normal operating envelope and the likely system failure point -- a system margin assessment. The fundamental concern with the use of energy metrics was that the applicability domain and implementation details were not completely defined for many problems of interest. The goal of this WSEAT project was to examine that domain of applicability and work out the necessarymore » implementation details. The goal of this project was to provide experimental validation for the energy spectra based methods in the context of margin assessment as they relate to shock environments. The extensive test results concluded that failure predictions using energy methods did not agree with failure predictions using S-N data. As a result, a modification to the energy methods was developed following the form of Basquin's equation to incorporate the power law exponent for fatigue damage. This update to the energy-based framework brings the energy based metrics into agreement with experimental data and historical S-N data.« less

  17. An Investigation of Rotorcraft Stability-Phase Margin Requirements in Hover

    NASA Technical Reports Server (NTRS)

    Blanken, Chris L.; Lusardi, Jeff A.; Ivler, Christina M.; Tischler, Mark B.; Hoefinger, Marc T.; Decker, William A.; Malpica, Carlos A.; Berger, Tom; Tucker, George E.

    2009-01-01

    A cooperative study was performed to investigate the handling quality effects from reduced flight control system stability margins, and the trade-offs with higher disturbance rejection bandwidth (DRB). The piloted simulation study, perform on the NASA-Ames Vertical Motion Simulator, included three classes of rotorcraft in four configurations: a utility-class helicopter; a medium-lift helicopter evaluated with and without an external slung load; and a large (heavy-lift) civil tiltrotor aircraft. This large aircraft also allowed an initial assessment of ADS-33 handling quality requirements for an aircraft of this size. Ten experimental test pilots representing the U.S. Army, Marine Corps, NASA, rotorcraft industry, and the German Aerospace Center (DLR), evaluated the four aircraft configurations, for a range of flight control stability-margins and turbulence levels, while primarily performing the ADS-33 Hover and Lateral Reposition MTEs. Pilot comments and aircraft-task performance data were analyzed. The preliminary stability margin results suggest higher DRB and less phase margin cases are preferred as the aircraft increases in size. Extra care will need to be taken to assess the influence of variability when nominal flight control gains start with reduced margins. Phase margins as low as 20-23 degrees resulted in low disturbance-response damping ratios, objectionable oscillations, PIO tendencies, and a perception of an incipient handling qualities cliff. Pilot comments on the disturbance response of the aircraft correlated well to the DRB guidelines provided in the ADS-33 Test Guide. The A D-3S3 mid-term response-to-control damping ratio metrics can be measured and applied to the disturbance-response damping ratio. An initial assessment of LCTR yaw bandwidth shows the current Level 1 boundary needs to be relaxed to help account for a large pilot off-set from the c.g. Future efforts should continue to investigate the applicability/refinement of the current ADS-33 requirements to large vehicles, like an LCTR.

  18. An assessment of PTV margin based on actual accumulated dose for prostate cancer radiotherapy

    NASA Astrophysics Data System (ADS)

    Wen, Ning; Kumarasiri, Akila; Nurushev, Teamour; Burmeister, Jay; Xing, Lei; Liu, Dezhi; Glide-Hurst, Carri; Kim, Jinkoo; Zhong, Hualiang; Movsas, Benjamin; Chetty, Indrin J.

    2013-11-01

    The purpose of this work is to present the results of a margin reduction study involving dosimetric and radiobiologic assessment of cumulative dose distributions, computed using an image guided adaptive radiotherapy based framework. Eight prostate cancer patients, treated with 7-9, 6 MV, intensity modulated radiation therapy (IMRT) fields, were included in this study. The workflow consists of cone beam CT (CBCT) based localization, deformable image registration of the CBCT to simulation CT image datasets (SIM-CT), dose reconstruction and dose accumulation on the SIM-CT, and plan evaluation using radiobiological models. For each patient, three IMRT plans were generated with different margins applied to the CTV. The PTV margin for the original plan was 10 mm and 6 mm at the prostate/anterior rectal wall interface (10/6 mm) and was reduced to: (a) 5/3 mm, and (b) 3 mm uniformly. The average percent reductions in predicted tumor control probability (TCP) in the accumulated (actual) plans in comparison to the original plans over eight patients were 0.4%, 0.7% and 11.0% with 10/6 mm, 5/3 mm and 3 mm uniform margin respectively. The mean increase in predicted normal tissue complication probability (NTCP) for grades 2/3 rectal bleeding for the actual plans in comparison to the static plans with margins of 10/6, 5/3 and 3 mm uniformly was 3.5%, 2.8% and 2.4% respectively. For the actual dose distributions, predicted NTCP for late rectal bleeding was reduced by 3.6% on average when the margin was reduced from 10/6 mm to 5/3 mm, and further reduced by 1.0% on average when the margin was reduced to 3 mm. The average reduction in complication free tumor control probability (P+) in the actual plans in comparison to the original plans with margins of 10/6, 5/3 and 3 mm was 3.7%, 2.4% and 13.6% correspondingly. The significant reduction of TCP and P+ in the actual plan with 3 mm margin came from one outlier, where individualizing patient treatment plans through margin adaptation based on biological models, might yield higher quality treatments.

  19. Histopathological Validation of the Surface-Intermediate-Base Margin Score for Standardized Reporting of Resection Technique during Nephron Sparing Surgery.

    PubMed

    Minervini, Andrea; Campi, Riccardo; Kutikov, Alexander; Montagnani, Ilaria; Sessa, Francesco; Serni, Sergio; Raspollini, Maria Rosaria; Carini, Marco

    2015-10-01

    The surface-intermediate-base margin score is a novel standardized reporting system of resection techniques during nephron sparing surgery. We validated the surgeon assessed surface-intermediate-base score with microscopic histopathological assessment of partial nephrectomy specimens. Between June and August 2014 data were prospectively collected from 40 consecutive patients undergoing nephron sparing surgery. The surface-intermediate-base score was assigned to all cases. The score specific areas were color coded with tissue margin ink and sectioned for histological evaluation of healthy renal margin thickness. Maximum, minimum and mean thickness of healthy renal margin for each score specific area grade (surface [S] = 0, S = 1 ; intermediate [I] or base [B] = 0, I or B = 1, I or B = 2) was reported. The Mann-Whitney U and Kruskal-Wallis tests were used to compare the thickness of healthy renal margin in S = 0 vs 1 and I or B = 0 vs 1 vs 2 grades, respectively. Maximum, minimum and mean thickness of healthy renal margin was significantly different among score specific area grades S = 0 vs 1, and I or B = 0 vs 1, 0 vs 2 and 1 vs 2 (p <0.001). The main limitations of the study are the low number of the I or B = 1 and I or B = 2 samples and the assumption that each microscopic slide reflects the entire score specific area for histological analysis. The surface-intermediate-base scoring method can be readily harnessed in real-world clinical practice and accurately mirrors histopathological analysis for quantification and reporting of healthy renal margin thickness removed during tumor excision. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  20. Preoperative (3-dimensional) computed tomography lung reconstruction before anatomic segmentectomy or lobectomy for stage I non-small cell lung cancer.

    PubMed

    Chan, Ernest G; Landreneau, James R; Schuchert, Matthew J; Odell, David D; Gu, Suicheng; Pu, Jiantao; Luketich, James D; Landreneau, Rodney J

    2015-09-01

    Accurate cancer localization and negative resection margins are necessary for successful segmentectomy. In this study, we evaluate a newly developed software package that permits automated segmentation of the pulmonary parenchyma, allowing 3-dimensional assessment of tumor size, location, and estimates of surgical margins. A pilot study using a newly developed 3-dimensional computed tomography analytic software package was performed to retrospectively evaluate preoperative computed tomography images of patients who underwent segmentectomy (n = 36) or lobectomy (n = 15) for stage 1 non-small cell lung cancer. The software accomplishes an automated reconstruction of anatomic pulmonary segments of the lung based on bronchial arborization. Estimates of anticipated surgical margins and pulmonary segmental volume were made on the basis of 3-dimensional reconstruction. Autosegmentation was achieved in 72.7% (32/44) of preoperative computed tomography images with slice thicknesses of 3 mm or less. Reasons for segmentation failure included local severe emphysema or pneumonitis, and lower computed tomography resolution. Tumor segmental localization was achieved in all autosegmented studies. The 3-dimensional computed tomography analysis provided a positive predictive value of 87% in predicting a marginal clearance greater than 1 cm and a 75% positive predictive value in predicting a margin to tumor diameter ratio greater than 1 in relation to the surgical pathology assessment. This preoperative 3-dimensional computed tomography analysis of segmental anatomy can confirm the tumor location within an anatomic segment and aid in predicting surgical margins. This 3-dimensional computed tomography information may assist in the preoperative assessment regarding the suitability of segmentectomy for peripheral lung cancers. Published by Elsevier Inc.

  1. The marginal fit of E.max Press and E.max CAD lithium disilicate restorations: A critical review.

    PubMed

    Mounajjed, Radek; M Layton, Danielle; Azar, Basel

    2016-12-01

    This critical review aimed to assess the vertical marginal gap that was present when E.max lithium disilicate-based restoration (Press and CAD) are fabricated in-vitro. Published articles reporting vertical marginal gap measurements of in-vitro restorations that had been fabricated from E.Max lithium disilicate were sought with an electronic search of MEDLINE (PubMed) and hand search of selected dental journals. The outcomes were reviewed qualitatively. The majority of studies that compared the marginal fit of E.max press and E.max CAD restorations, found that the E.max lithium disilicate restorations fabricated with the press technique had significantly smaller marginal gaps than those fabricated with CAD technique. This research indicates that E.max lithium disilicate restorations fabricated with the press technique have measurably smaller marginal gaps when compared with those fabricated with CAD techniques within in-vitro environments. The marginal gaps achieved by the restorations across all groups were within a clinically acceptable range.

  2. Sca-1(+) mesenchymal stromal cells inhibit splenic marginal zone B lymphocytes commitment through Caspase-3.

    PubMed

    Chen, Yaozhen; Yang, Jialei; Zhang, Hui-Jie; Fan, Hong; An, Ning; Xin, Jiajia; Li, Na; Xu, Jinmei; Yin, Wen; Wu, Zhongliang; Hu, Xingbin

    2016-05-01

    Mesenchymal stromal cells (MSCs) have been characterized as an important component of hematopoietic niche, which are capable of modulating the immune system through interaction with a wide range of immune cells. Marginal zone B cells, one main type of mature B lymphocytes, play a central role in eliciting antibody response against pathogens. However, how MSCs and its subpopulations regulate marginal zone B cells commitment is unknown yet. In this study, we assessed the contribution of Sca-1(+) MSCs on marginal zone B cells commitment. Our results showed that Sca-1(+) MSCs inhibit the commitment of marginal zone B lymphocytes. The inhibition was exerted through lowered Caspase-3 expression. Furthermore, we found marginal zone B lymphocytes in spleen of Caspase-3 knockout mice decreased and Caspase-3 knockout Sca-1(+) MSCs accounted for the MZB lymphocytes decrease. In conclusion, our investigation provided clues about Sca-1(+) MSCs regulation on the commitment of marginal zone B cells through Caspase-3 gene. © 2016 International Federation for Cell Biology.

  3. Targeting the impact of agri-environmental policy - Future scenarios in two less favoured areas in Portugal.

    PubMed

    Jones, Nadia; Fleskens, Luuk; Stroosnijder, Leo

    2016-10-01

    Targeting agri-environmental measures (AEM) improves their effectiveness in the delivery of public goods, provided the necessary coordination with other incentives. In less favoured areas (LFA) measures focusing on the conservation of extensive farming contribute to sustainable land management in these areas. In this paper we investigate the implementation of a possible AEM supporting the improvement of permanent pastures coordinated with the extensive livestock and single farm payments actually in place. Through applying a spatially-explicit mixed integer optimisation model we simulate future land use scenarios for two less favoured areas in Portugal (Centro and Alentejo) considering two policy scenarios: a 'targeted AEM', and a 'non-targeted AEM'. We then compare the results with a 'basic policy' option (reflecting a situation without AEM). This is done with regard to landscape-scale effects on the reduction of fire hazard and erosion risk, as well as effects on farm income. The results show that an AEM for permanent pastures would be more cost-effective for erosion and fire hazard mitigation if implemented within a spatially targeted framework. However when cost-effectiveness is assessed with other indicators (e.g. net farm income and share of grazing livestock) 'non-targeted AEM' implementation delivers the best outcome in Alentejo. In Centro the implementation of an AEM involves important losses of income compared to the 'basic policy'. 'Targeted AEM' tends to favour farms in very marginal conditions, i.e. targeting is demonstrated to perform best in landscapes where spatial heterogeneity is higher. The results also show the risk of farm abandonment in the two studied less favoured areas: in all three scenarios more than 30% of arable land is deemed to be abandoned. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Differential Motion Between Mediastinal Lymph Nodes and Primary Tumor in Radically Irradiated Lung Cancer Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schaake, Eva E.; Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam; Rossi, Maddalena M.G.

    2014-11-15

    Purpose/Objective: In patients with locally advanced lung cancer, planning target volume margins for mediastinal lymph nodes and tumor after a correction protocol based on bony anatomy registration typically range from 1 to 1.5 cm. Detailed information about lymph node motion variability and differential motion with the primary tumor, however, is lacking from large series. In this study, lymph node and tumor position variability were analyzed in detail and correlated to the main carina to evaluate possible margin reduction. Methods and Materials: Small gold fiducial markers (0.35 × 5 mm) were placed in the mediastinal lymph nodes of 51 patients with non-small cell lung cancermore » during routine diagnostic esophageal or bronchial endoscopic ultrasonography. Four-dimensional (4D) planning computed tomographic (CT) and daily 4D cone beam (CB) CT scans were acquired before and during radical radiation therapy (66 Gy in 24 fractions). Each CBCT was registered in 3-dimensions (bony anatomy) and 4D (tumor, marker, and carina) to the planning CT scan. Subsequently, systematic and random residual misalignments of the time-averaged lymph node and tumor position relative to the bony anatomy and carina were determined. Additionally, tumor and lymph node respiratory amplitude variability was quantified. Finally, required margins were quantified by use of a recipe for dual targets. Results: Relative to the bony anatomy, systematic and random errors ranged from 0.16 to 0.32 cm for the markers and from 0.15 to 0.33 cm for the tumor, but despite similar ranges there was limited correlation (0.17-0.71) owing to differential motion. A large variability in lymph node amplitude between patients was observed, with an average motion of 0.56 cm in the cranial-caudal direction. Margins could be reduced by 10% (left-right), 27% (cranial-caudal), and 10% (anteroposterior) for the lymph nodes and −2%, 15%, and 7% for the tumor if an online carina registration protocol replaced a protocol based on bony anatomy registration. Conclusions: Detailed analysis revealed considerable lymph node position variability, differential motion, and respiratory motion. Planning target volume margins can be reduced up to 27% in lung cancer patients when the carina registration replaces bony anatomy registration.« less

  5. [Organ-limited prostate cancer with positive resection margins. Importance of adjuvant radiation therapy].

    PubMed

    Porres, D; Pfister, D; Brehmer, B; Heidenreich, A

    2012-09-01

    For pT3 prostate cancer with positive resection margins, the importance of postoperative radiation therapy is confirmed by a high level of evidence. However, for the pT2,R1 situation prospective, randomized studies concerning this question are lacking. Despite better local tumor control in the pT2 stage the PSA recurrence rate lies between 25% and 40% and positive margins are an independent factor for recurrence. Retrospective studies suggest a positive effect of adjuvant or salvage radiation for the oncological outcome in the pT2,R1 situation. On the other hand the side effects profile, with a potentially negative influence of postoperative continence and various delayed toxicities, is not insignificant despite modern radiation techniques and in the era of ultrasensitive PSA analysis should be considered in the risk-benefit assessment. As long as the optimal initiation of postoperative radiation therapy is unclear, the assessment of indications for adjuvant or salvage radiation for organ-limited prostate cancer with positive resection margins should be made after an individual patient consultation and under consideration of the recurrence risk factors, such as the Gleason grade and the localization and extent of the resection margins.

  6. Extensional Fault Evolution and its Flexural Isostatic Response During Iberia-Newfoundland Rifted Margin Formation

    NASA Astrophysics Data System (ADS)

    Gómez-Romeu, J.; Kusznir, N.; Manatschal, G.; Roberts, A.

    2017-12-01

    During the formation of magma-poor rifted margins, upper lithosphere thinning and stretching is achieved by extensional faulting, however, there is still debate and uncertainty how faults evolve during rifting leading to breakup. Seismic data provides an image of the present-day structural and stratigraphic configuration and thus initial fault geometry is unknown. To understand the geometric evolution of extensional faults at rifted margins it is extremely important to also consider the flexural response of the lithosphere produced by fault displacement resulting in footwall uplift and hangingwall subsidence. We investigate how the flexural isostatic response to extensional faulting controls the structural development of rifted margins. To achieve our aim, we use a kinematic forward model (RIFTER) which incorporates the flexural isostatic response to extensional faulting, crustal thinning, lithosphere thermal loads, sedimentation and erosion. Inputs for RIFTER are derived from seismic reflection interpretation and outputs of RIFTER are the prediction of the structural and stratigraphic consequences of recursive sequential faulting and sedimentation. Using RIFTER we model the simultaneous tectonic development of the Iberia-Newfoundland conjugate rifted margins along the ISE01-SCREECH1 and TGS/LG12-SCREECH2 seismic lines. We quantitatively test and calibrate the model against observed target data restored to breakup time. Two quantitative methods are used to obtain this target data: (i) gravity anomaly inversion which predicts Moho depth and continental lithosphere thinning and (ii) reverse post-rift subsidence modelling to give water and Moho depths at breakup time. We show that extensional faulting occurs on steep ( 60°) normal faults in both proximal and distal parts of rifted margins. Extensional faults together with their flexural isostatic response produce not only sub-horizontal exhumed footwall surfaces (i.e. the rolling hinge model) and highly rotated (60° or more) pre- and syn-rift stratigraphy, but also extensional allochthons underlain by apparent horizontal detachments. These detachment faults were never active in this sub-horizontal geometry; they were only active as steep faults which were isostatically rotated to their present sub-horizontal position.

  7. Inter- and Intrafraction Target Motion in Highly Focused Single Vocal Cord Irradiation of T1a Larynx Cancer Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kwa, Stefan L.S., E-mail: s.kwa@erasmusmc.nl; Al-Mamgani, Abrahim; Osman, Sarah O.S.

    2015-09-01

    Purpose: The purpose of this study was to verify clinical target volume–planning target volume (CTV-PTV) margins in single vocal cord irradiation (SVCI) of T1a larynx tumors and characterize inter- and intrafraction target motion. Methods and Materials: For 42 patients, a single vocal cord was irradiated using intensity modulated radiation therapy at a total dose of 58.1 Gy (16 fractions × 3.63 Gy). A daily cone beam computed tomography (CBCT) scan was performed to online correct the setup of the thyroid cartilage after patient positioning with in-room lasers (interfraction motion correction). To monitor intrafraction motion, CBCT scans were also acquired just after patient repositioning and aftermore » dose delivery. A mixed online-offline setup correction protocol (“O2 protocol”) was designed to compensate for both inter- and intrafraction motion. Results: Observed interfraction, systematic (Σ), and random (σ) setup errors in left-right (LR), craniocaudal (CC), and anteroposterior (AP) directions were 0.9, 2.0, and 1.1 mm and 1.0, 1.6, and 1.0 mm, respectively. After correction of these errors, the following intrafraction movements derived from the CBCT acquired after dose delivery were: Σ = 0.4, 1.3, and 0.7 mm, and σ = 0.8, 1.4, and 0.8 mm. More than half of the patients showed a systematic non-zero intrafraction shift in target position, (ie, the mean intrafraction displacement over the treatment fractions was statistically significantly different from zero; P<.05). With the applied CTV-PTV margins (for most patients 3, 5, and 3 mm in LR, CC, and AP directions, respectively), the minimum CTV dose, estimated from the target displacements observed in the last CBCT, was at least 94% of the prescribed dose for all patients and more than 98% for most patients (37 of 42). The proposed O2 protocol could effectively reduce the systematic intrafraction errors observed after dose delivery to almost zero (Σ = 0.1, 0.2, 0.2 mm). Conclusions: With adequate image guidance and CTV-PTV margins in LR, CC, and AP directions of 3, 5, and 3 mm, respectively, excellent target coverage in SVCI could be ensured.« less

  8. Dosimetric consequences of translational and rotational errors in frame-less image-guided radiosurgery

    PubMed Central

    2012-01-01

    Background To investigate geometric and dosimetric accuracy of frame-less image-guided radiosurgery (IG-RS) for brain metastases. Methods and materials Single fraction IG-RS was practiced in 72 patients with 98 brain metastases. Patient positioning and immobilization used either double- (n = 71) or single-layer (n = 27) thermoplastic masks. Pre-treatment set-up errors (n = 98) were evaluated with cone-beam CT (CBCT) based image-guidance (IG) and were corrected in six degrees of freedom without an action level. CBCT imaging after treatment measured intra-fractional errors (n = 64). Pre- and post-treatment errors were simulated in the treatment planning system and target coverage and dose conformity were evaluated. Three scenarios of 0 mm, 1 mm and 2 mm GTV-to-PTV (gross tumor volume, planning target volume) safety margins (SM) were simulated. Results Errors prior to IG were 3.9 mm ± 1.7 mm (3D vector) and the maximum rotational error was 1.7° ± 0.8° on average. The post-treatment 3D error was 0.9 mm ± 0.6 mm. No differences between double- and single-layer masks were observed. Intra-fractional errors were significantly correlated with the total treatment time with 0.7mm±0.5mm and 1.2mm±0.7mm for treatment times ≤23 minutes and >23 minutes (p<0.01), respectively. Simulation of RS without image-guidance reduced target coverage and conformity to 75% ± 19% and 60% ± 25% of planned values. Each 3D set-up error of 1 mm decreased target coverage and dose conformity by 6% and 10% on average, respectively, with a large inter-patient variability. Pre-treatment correction of translations only but not rotations did not affect target coverage and conformity. Post-treatment errors reduced target coverage by >5% in 14% of the patients. A 1 mm safety margin fully compensated intra-fractional patient motion. Conclusions IG-RS with online correction of translational errors achieves high geometric and dosimetric accuracy. Intra-fractional errors decrease target coverage and conformity unless compensated with appropriate safety margins. PMID:22531060

  9. Defining the Optimal Planning Target Volume in Image-Guided Stereotactic Radiosurgery of Brain Metastases: Results of a Randomized Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kirkpatrick, John P., E-mail: john.kirkpatrick@dm.duke.edu; Department of Surgery, Duke University, Durham, North Carolina; Wang, Zhiheng

    2015-01-01

    Purpose: To identify an optimal margin about the gross target volume (GTV) for stereotactic radiosurgery (SRS) of brain metastases, minimizing toxicity and local recurrence. Methods and Materials: Adult patients with 1 to 3 brain metastases less than 4 cm in greatest dimension, no previous brain radiation therapy, and Karnofsky performance status (KPS) above 70 were eligible for this institutional review board–approved trial. Individual lesions were randomized to 1- or 3- mm uniform expansion of the GTV defined on contrast-enhanced magnetic resonance imaging (MRI). The resulting planning target volume (PTV) was treated to 24, 18, or 15 Gy marginal dose for maximum PTV diametersmore » less than 2, 2 to 2.9, and 3 to 3.9 cm, respectively, using a linear accelerator–based image-guided system. The primary endpoint was local recurrence (LR). Secondary endpoints included neurocognition Mini-Mental State Examination, Trail Making Test Parts A and B, quality of life (Functional Assessment of Cancer Therapy-Brain), radionecrosis (RN), need for salvage radiation therapy, distant failure (DF) in the brain, and overall survival (OS). Results: Between February 2010 and November 2012, 49 patients with 80 brain metastases were treated. The median age was 61 years, the median KPS was 90, and the predominant histologies were non–small cell lung cancer (25 patients) and melanoma (8). Fifty-five, 19, and 6 lesions were treated to 24, 18, and 15 Gy, respectively. The PTV/GTV ratio, volume receiving 12 Gy or more, and minimum dose to PTV were significantly higher in the 3-mm group (all P<.01), and GTV was similar (P=.76). At a median follow-up time of 32.2 months, 11 patients were alive, with median OS 10.6 months. LR was observed in only 3 lesions (2 in the 1 mm group, P=.51), with 6.7% LR 12 months after SRS. Biopsy-proven RN alone was observed in 6 lesions (5 in the 3-mm group, P=.10). The 12-month DF rate was 45.7%. Three months after SRS, no significant change in neurocognition or quality of life was observed. Conclusions: SRS was well tolerated, with low rates of LR and RN in both cohorts. However, given the higher potential risk of RN with a 3-mm margin, a 1-mm GTV expansion is more appropriate.« less

  10. Circumferential fit assessment of CAD/CAM single crowns--a pilot investigation on a new virtual analytical protocol.

    PubMed

    Matta, Ragai E; Schmitt, Johannes; Wichmann, Manfred; Holst, Stefan

    2012-10-01

    Techniques currently applied to determine the marginal accuracy of dental crown restorations yield inadequate information. This investigation aimed to test a new virtual approach for determining the precision of fit of single-crown copings. Zirconia single crown copings were manufactured on 10 gypsum, single-tooth master casts with two different established computer-aided design/computer-assisted manufacture (CAD/CAM) systems (groups A and B). After cementation, the circumferential fit was assessed with an industrial noncontact scanner and virtual 3D analysis, following a triple-scan protocol. Marginal fit was determined by virtual sectioning; each abutment-coping complex was digitally sliced in 360 vertical sections (1 degree per section). Standardized measurement distances for analyzing the marginal fit (z, xy, xyz) were selected, and a crosshair alignment was utilized to determine whether crowns were horizontally and/or vertically too large or small. The Mann-Whitney test was applied to test for differences between groups. Significant differences in the xy direction (P = .008) were measured between groups. Group A showed a greater number of horizontally overextended margins and a higher frequency of xy distances greater than 150 Μm, in addition to a tendency for excessive z distances (P = .095). The mean marginal gap values were clinically acceptable in the present investigation; however, a full circumferential analysis revealed significant differences in marginal coping quality.

  11. Independent Predictors of Prognosis Based on Oral Cavity Squamous Cell Carcinoma Surgical Margins.

    PubMed

    Buchakjian, Marisa R; Ginader, Timothy; Tasche, Kendall K; Pagedar, Nitin A; Smith, Brian J; Sperry, Steven M

    2018-05-01

    Objective To conduct a multivariate analysis of a large cohort of oral cavity squamous cell carcinoma (OCSCC) cases for independent predictors of local recurrence (LR) and overall survival (OS), with emphasis on the relationship between (1) prognosis and (2) main specimen permanent margins and intraoperative tumor bed frozen margins. Study Design Retrospective cohort study. Setting Tertiary academic head and neck cancer program. Subjects and Methods This study included 426 patients treated with OCSCC resection between 2005 and 2014 at University of Iowa Hospitals and Clinics. Patients underwent excision of OCSCC with intraoperative tumor bed frozen margin sampling and main specimen permanent margin assessment. Multivariate analysis of the data set to predict LR and OS was performed. Results Independent predictors of LR included nodal involvement, histologic grade, and main specimen permanent margin status. Specifically, the presence of a positive margin (odds ratio, 6.21; 95% CI, 3.3-11.9) or <1-mm/carcinoma in situ margin (odds ratio, 2.41; 95% CI, 1.19-4.87) on the main specimen was an independent predictor of LR, whereas intraoperative tumor bed margins were not predictive of LR on multivariate analysis. Similarly, independent predictors of OS on multivariate analysis included nodal involvement, extracapsular extension, and a positive main specimen margin. Tumor bed margins did not independently predict OS. Conclusion The main specimen margin is a strong independent predictor of LR and OS on multivariate analysis. Intraoperative tumor bed frozen margins do not independently predict prognosis. We conclude that emphasis should be placed on evaluating the main specimen margins when estimating prognosis after OCSCC resection.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muller, L; Soldner, A; Kirk, M

    Purpose: The beam range uncertainty presents a special challenge for proton therapy. Novel technologies currently under development offer strategies to reduce the range uncertainty [1,2]. This work quantifies the potential advantages that could be realized by such a reduction for dosimetrically challenging chordomas at the base of skull. Therapeutic improvement was assessed by evaluating tumor control probabilities (TCP) and normal tissue complication probabilities (NTCP). Methods: Treatment plans were made for a modulated-scanned proton delivery technique using the Eclipse treatment planning system. The prescription dose was 7920 cGy to the CTV. Three different range uncertainty scenarios were considered: 5 mm (3.5%more » of the beam range + 1 mm, representing current clinical practice, “Curr”), 2 mm (1.3%), and 1 mm (0.7%). For each of 4 patients, 3 different PTVs were defined via uniform expansion of the CTV by the value of the range uncertainty. Tumor control probability (TCP) and normal tissue complication probabilities (NTCPs) for organs-at-risk (OARs) were calculated using the Lyman-Kutcher-Burman[3] formalism and published model parameters [ref Terahara[4], quantec S10, Burman Red Journal v21 pp 123]. Our plan optimization strategy was to achieve PTV close to prescription while maintaining OAR NTCP values at or better than the Curr plan. Results: The average TCP values for the 5, 2, and 1 mm range uncertainty scenarios are 51%, 55% and 65%. The improvement in TCP for patients was between 4 and 30%, depending primarily on the proximity of the GTV to OAR. The average NTCPs for the brainstem and cord were about 4% and 1%, respectively, for all target margins. Conclusion: For base of skull chordomas, reduced target margins can substantially increase the TCP without increasing the NTCP. This work demonstrates the potential significance of a reduction in the range uncertainty for proton beams.« less

  13. Portal imaging based definition of the planning target volume during pelvic irradiation for gynecological malignancies.

    PubMed

    Mock, U; Dieckmann, K; Wolff, U; Knocke, T H; Pötter, R

    1999-08-01

    Geometrical accuracy in patient positioning can vary substantially during external radiotherapy. This study estimated the set-up accuracy during pelvic irradiation for gynecological malignancies for determination of safety margins (planning target volume, PTV). Based on electronic portal imaging devices (EPID), 25 patients undergoing 4-field pelvic irradiation for gynecological malignancies were analyzed with regard to set-up accuracy during the treatment course. Regularly performed EPID images were used in order to systematically assess the systematic and random component of set-up displacements. Anatomical matching of verification and simulation images was followed by measuring corresponding distances between the central axis and anatomical features. Data analysis of set-up errors referred to the x-, y-,and z-axes. Additionally, cumulative frequencies were evaluated. A total of 50 simulation films and 313 verification images were analyzed. For the anterior-posterior (AP) beam direction mean deviations along the x- and z-axes were 1.5 mm and -1.9 mm, respectively. Moreover, random errors of 4.8 mm (x-axis) and 3.0 mm (z-axis) were determined. Concerning the latero-lateral treatment fields, the systematic errors along the two axes were calculated to 2.9 mm (y-axis) and -2.0 mm (z-axis) and random errors of 3.8 mm and 3.5 mm were found, respectively. The cumulative frequency of misalignments < or =5 mm showed values of 75% (AP fields) and 72% (latero-lateral fields). With regard to cumulative frequencies < or =10 mm quantification revealed values of 97% for both beam directions. During external pelvic irradiation therapy for gynecological malignancies, EPID images on a regular basis revealed acceptable set-up inaccuracies. Safety margins (PTV) of 1 cm appear to be sufficient, accounting for more than 95% of all deviations.

  14. Development and evaluation of a connective tissue phantom model for subsurface visualization of cancers requiring wide local excision

    NASA Astrophysics Data System (ADS)

    Samkoe, Kimberley S.; Bates, Brent D.; Tselepidakis, Niki N.; DSouza, Alisha V.; Gunn, Jason R.; Ramkumar, Dipak B.; Paulsen, Keith D.; Pogue, Brian W.; Henderson, Eric R.

    2017-12-01

    Wide local excision (WLE) of tumors with negative margins remains a challenge because surgeons cannot directly visualize the mass. Fluorescence-guided surgery (FGS) may improve surgical accuracy; however, conventional methods with direct surface tumor visualization are not immediately applicable, and properties of tissues surrounding the cancer must be considered. We developed a phantom model for sarcoma resection with the near-infrared fluorophore IRDye 800CW and used it to iteratively define the properties of connective tissues that typically surround sarcoma tumors. We then tested the ability of a blinded surgeon to resect fluorescent tumor-simulating inclusions with ˜1-cm margins using predetermined target fluorescence intensities and a Solaris open-air fluorescence imaging system. In connective tissue-simulating phantoms, fluorescence intensity decreased with increasing blood concentration and increased with increasing intralipid concentrations. Fluorescent inclusions could be resolved at ≥1-cm depth in all inclusion concentrations and sizes tested. When inclusion depth was held constant, fluorescence intensity decreased with decreasing volume. Using targeted fluorescence intensities, a blinded surgeon was able to successfully excise inclusions with ˜1-cm margins from fat- and muscle-simulating phantoms with inclusion-to-background contrast ratios as low as 2∶1. Indirect, subsurface FGS is a promising tool for surgical resection of cancers requiring WLE.

  15. Spectrally encoded confocal microscopy (SECM) for rapid assessment of breast excision specimens (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Brachtel, Elena F.; Johnson, Nicole B.; Huck, Amelia E.; Rice-Stitt, Travis L.; Vangel, Mark G.; Smith, Barbara L.; Tearney, Guillermo J.; Kang, DongKyun

    2016-03-01

    Unacceptably large percentage (20-40%) of breast cancer lumpectomy patients are required to undergo multiple surgeries when positive margins are found upon post-operative histologic assessment. If the margin status can be determined during surgery, surgeon can resect additional tissues to achieve tumor-free margin, which will reduce the need for additional surgeries. Spectrally encoded confocal microscopy (SECM) is a high-speed reflectance confocal microscopy technology that has a potential to image the entire surgical margin within a short procedural time. Previously, SECM was shown to rapidly image a large area (10 mm by 10 mm) of human esophageal tissue within a short procedural time (15 seconds). When used in lumpectomy, SECM will be able to image the entire margin surface of ~30 cm2 in around 7.5 minutes. SECM images will then be used to determine margin status intra-operatively. In this paper, we present results from a study of testing accuracy of SECM for diagnosing malignant breast tissues. We have imaged freshly-excised breast specimens (N=46) with SECM. SECM images clearly visualized histomorphologic features associated with normal/benign and malignant breast tissues in a similar manner to histologic images. Diagnostic accuracy was tested by comparing SECM diagnoses made by three junior pathologists with corresponding histologic diagnoses made by a senior pathologist. SECM sensitivity and specificity were high, 0.91 and 0.93, respectively. Intra-observer agreement and inter-observer agreement were also high, 0.87 and 0.84, respectively. Results from this study showed that SECM has a potential to accurately determine margin status during breast cancer lumpectomy.

  16. Number of fragments, margin status and thermal artifacts of conized specimens from LLETZ surgery to treat cervical intraepithelial neoplasia.

    PubMed

    Bittencourt, Dulcimary Dias; Zanine, Rita Maira; Sebastião, Ana Martins; Taha, Nabiha Saadi; Speck, Neila Góis; Ribalta, Julisa Chamorro Lascasas

    2012-01-01

    Large loop excision of the transformation zone (LLETZ) is a nontraumatic cut and coagulation method with several advantages, but it induces thermal artifacts in the cut region. The aim here was to assess the correlations of age, number of fragments, lesion grade and degree of thermal artifacts with margin quality in conized specimens from LLETZ for cervical intraepithelial neoplasia (CIN). Cross-sectional study at Universidade Federal de São Paulo (Unifesp). The records and histopathology findings of 118 women who underwent LLETZ between 1999 and 2007 were reviewed. Age, number of fragments, lesion grade, degree of thermal artifacts and margin quality were assessed. The patients' mean age was 27.14 years; 63.6% had been diagnosed with CIN II and 36.4% with CIN III. The lesion was removed as a single fragment in 79.6% of the cases. The margins were free from intraepithelial neoplasia in 85.6% and compromised in the endocervical margin in 6.8%. Fragment damage due to artifacts occurred in 2.5%. Severe artifacts occurred in 22.8%. Women aged 30 years or over presented more cases of CIN III (P < 0.0004). Neoplastic compromising of surgical margins and severe artifacts occurred more often in cases in which two or more fragments were removed, and in patients aged 30 years or over. CIN III in women aged 30 or over, when removed in two or more fragments during LLETZ, presented a greater number of compromised margins and greater severity of thermal artifacts.

  17. Economic Implications of Widespread Expansion of Frozen Section Margin Analysis to Guide Surgical Resection in Women With Breast Cancer Undergoing Breast-Conserving Surgery.

    PubMed

    Boughey, Judy C; Keeney, Gary L; Radensky, Paul; Song, Christine P; Habermann, Elizabeth B

    2016-04-01

    In the current health care environment, cost effectiveness is critically important in policy setting and care of patients. This study performed a health economic analysis to assess the implications to providers and payers of expanding the use of frozen section margin analysis to minimize reoperations for patients undergoing breast cancer lumpectomy. A health care economic impact model was built to assess annual costs associated with breast lumpectomy procedures with and without frozen section margin analysis to avoid reoperation. If frozen section margin analysis is used in 20% of breast lumpectomies and under a baseline assumption that 35% of initial lumpectomies without frozen section analysis result in reoperations, the potential annual cost savings are $18.2 million to payers and $0.4 million to providers. Under the same baseline assumption, if 100% of all health care facilities adopted the use of frozen section margin analysis for breast lumpectomy procedures, the potential annual cost savings are $90.9 million to payers and $1.8 million to providers. On the basis of 10,000 simulations, use of intraoperative frozen section margin analysis yields cost saving for payers and is cost neutral to slightly cost saving for providers. This economic analysis indicates that widespread use of frozen section margin evaluation intraoperatively to guide surgical resection in breast lumpectomy cases and minimize reoperations would be beneficial to cost savings not only for the patient but also for payers and, in most cases, for providers. Copyright © 2016 by American Society of Clinical Oncology.

  18. Proton therapy of prostate cancer by anterior-oblique beams: implications of setup and anatomy variations

    NASA Astrophysics Data System (ADS)

    Moteabbed, M.; Trofimov, A.; Sharp, G. C.; Wang, Y.; Zietman, A. L.; Efstathiou, J. A.; Lu, H.-M.

    2017-03-01

    Proton therapy of prostate by anterior beams could offer an attractive option for treating patients with hip prosthesis and limiting the high-dose exposure to the rectum. We investigated the impact of setup and anatomy variations on the anterior-oblique (AO) proton plan dose, and strategies to manage these effects via range verification and adaptive delivery. Ten patients treated by bilateral (BL) passive-scattering proton therapy (79.2 Gy in 44 fractions) who underwent weekly verification CT scans were selected. Plans with AO beams were additionally created. To isolate the effect of daily variations, initial AO plans did not include range uncertainty margins. The use of fixed planning margins and adaptive range adjustments to manage these effects was investigated. For each case, the planned dose was recalculated on weekly CTs, and accumulated on the simulation CT using deformable registration to approximate the delivered dose. Planned and accumulated doses were compared for each scenario to quantify dose deviations induced by variations. The possibility of estimating the necessary range adjustments before each treatment was explored by simulating the procedure of a diode-based in vivo range verification technique, which would potentially be used clinically. The average planned rectum, penile bulb and femoral heads mean doses were smaller for initial AO compared to BL plans (by 8.3, 16.1 and 25.9 Gy, respectively). After considering interfractional variations in AO plans, the target coverage was substantially reduced. The maximum reduction of V 79.2/D 95/D mean/EUD for AO (without distal margins) (25.3%/10.7/1.6/4.9 Gy, respectively) was considerably larger than BL plans. The loss of coverage was mainly related to changes in water equivalent path length of the prostate after fiducial-based setup, caused by discrepancies in patient anterior surface and bony-anatomy alignment. Target coverage was recovered partially when using fixed planning margins, and fully when applying adaptive range adjustments. The accumulated organs-at-risk dose for AO beams after range adjustment demonstrated full sparing of femoral heads and superior sparing of penile bulb and rectum compared to the conventional BL cases. Our study indicates that using AO beams makes prostate treatment more susceptible to target underdose induced by interfractional variations. Adaptive range verification/adjustment may facilitate the use of anterior beam approaches, and ensure adequate target coverage in every fraction of the treatment.

  19. Technology-Enhanced Stepped Collaborative Care Targeting Posttraumatic Stress Disorder and Comorbidity After Injury: A Randomized Controlled Trial.

    PubMed

    Zatzick, Douglas; O'Connor, Stephen S; Russo, Joan; Wang, Jin; Bush, Nigel; Love, Jeff; Peterson, Roselyn; Ingraham, Leah; Darnell, Doyanne; Whiteside, Lauren; Van Eaton, Erik

    2015-10-01

    Posttraumatic stress disorder (PTSD) and its comorbidities are endemic among injured trauma survivors. Previous collaborative care trials targeting PTSD after injury have been effective, but they have required intensive clinical resources. The present pragmatic clinical trial randomized acutely injured trauma survivors who screened positive on an automated electronic medical record PTSD assessment to collaborative care intervention (n = 60) and usual care control (n = 61) conditions. The stepped measurement-based intervention included care management, psychopharmacology, and psychotherapy elements. Embedded within the intervention were a series of information technology (IT) components. PTSD symptoms were assessed with the PTSD Checklist at baseline prerandomization and again, 1-, 3-, and 6-months postinjury. IT utilization was also assessed. The technology-assisted intervention required a median of 2.25 hours (interquartile range = 1.57 hours) per patient. The intervention was associated with modest symptom reductions, but beyond the margin of statistical significance in the unadjusted model: F(2, 204) = 2.95, p = .055. The covariate adjusted regression was significant: F(2, 204) = 3.06, p = .049. The PTSD intervention effect was greatest at the 3-month (Cohen's effect size d = 0.35, F(1, 204) = 4.11, p = .044) and 6-month (d = 0.38, F(1, 204) = 4.10, p = .044) time points. IT-enhanced collaborative care was associated with modest PTSD symptom reductions and reduced delivery times; the intervention model could potentially facilitate efficient PTSD treatment after injury. Copyright © 2015 Wiley Periodicals, Inc., A Wiley Company.

  20. Implementing demand side targeting mechanisms for maternal and child health-experiences from national health insurance fund program in Rungwe District, Tanzania.

    PubMed

    Kuwawenaruwa, August; Mtei, Gemini; Baraka, Jitihada; Tani, Kassimu

    2016-08-02

    Low and middle income countries have adopted targeting mechanisms as a means of increasing program efficiency in reaching marginalized people in the community given the available resources. Design of targeting mechanisms has been changing over time and it is important to understand implementers' experience with such targeting mechanisms since such mechanisms impact equity in access and use of maternal health care services. The case study approach was considered as appropriate method for exploring implementers' and decision-makers' experiences with the two targeting mechanisms. In-depth interviews in order to explore implementer experience with the two targeting mechanisms. A total of 10 in-depth interviews (IDI) and 4 group discussions (GDs) were conducted with implementers at national level, regional, district and health care facility level. A thematic analysis approach was adopted during data analysis. The whole process of screening and identifying poor pregnant women resulted in delay in implementation of the intervention. Individual targeting was perceived to have some form of stigmatization; hence beneficiaries did not like to be termed as poor. Geographical targeting had a few cons as health care providers experienced an increase in workload while staff remained the same and poor quality of information in the claim forms. However geographical targeting increase in the number of women going to higher level of care (district/regional referral hospital), increase in facility revenue and insurance coverage. Interventions which are using targeting mechanisms to reach poor people are useful in increasing access and use of health care services for marginalized communities so long as they are well designed and beneficiaries as well as all implementers and decision makers are involved from the very beginning. Implementation of demand side financing strategies using targeting mechanisms should go together with supply side interventions in order to achieve project objectives.

  1. Adverse consequences of student drinking: the role of sex, social anxiety, drinking motives.

    PubMed

    Norberg, Melissa M; Olivier, Jake; Alperstein, Dion M; Zvolensky, Michael J; Norton, Alice R

    2011-08-01

    This study examined whether biological sex, social anxiety, and drinking motives relate differently to distinct types of alcohol-related consequences using Poisson regression. One hundred eighteen college students completed self-report measures assessing drinking motives and social anxiety and an interview assessing alcohol consumption and consequences. Highly socially anxious women were particularly apt to experience adverse role functioning consequences, while men were particularly apt to experience physical consequences. Although highly socially anxious women reported more personal consequences than did women with low to moderate social anxiety, men with low to moderate social anxiety reported experiencing more social and personal consequences than did women with low to moderate social anxiety. When taking into consideration the above associations, coping motives were statistically associated with social consequences and marginally related to personal consequences, while enhancement motives were significantly associated with physical consequences. Targeting these factors may lead to effective interventions for individuals with co-occurring social anxiety and drinking problems. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. Marginal cost curves for water footprint reduction in irrigated agriculture: a policy and decision making guide for efficient water use in crop production

    NASA Astrophysics Data System (ADS)

    Chukalla, Abebe; Krol, Maarten; Hoekstra, Arjen

    2016-04-01

    Reducing water footprints (WF) in irrigated crop production is an essential element in water management, particularly in water-scarce areas. To achieve this, policy and decision making need to be supported with information on marginal cost curves that rank measures to reduce the WF according to their cost-effectiveness and enable the estimation of the cost associated with a certain WF reduction target, e.g. towards a certain reasonable WF benchmark. This paper aims to develop marginal cost curves (MCC) for WF reduction. The AquaCrop model is used to explore the effect of different measures on evapotranspiration and crop yield and thus WF that is used as input in the MCC. Measures relate to three dimensions of management practices: irrigation techniques (furrow, sprinkler, drip and subsurface drip); irrigation strategies (full and deficit irrigation); and mulching practices (no mulching, organic and synthetic mulching). A WF benchmark per crop is calculated as resulting from the best-available production technology. The marginal cost curve is plotted using the ratios of the marginal cost to WF reduction of the measures as ordinate, ranking with marginal costs rise with the increase of the reduction effort. For each measure, the marginal cost to reduce WF is estimated by comparing the associated WF and net present value (NPV) to the reference case (furrow irrigation, full irrigation, no mulching). The NPV for each measure is based on its capital costs, operation and maintenances costs (O&M) and revenues. A range of cases is considered, including: different crops, soil types and different environments. Key words: marginal cost curve, water footprint benchmark, soil water balance, crop growth, AquaCrop

  3. Toroidal marginally outer trapped surfaces in closed Friedmann-Lemaître-Robertson-Walker spacetimes: Stability and isoperimetric inequalities

    NASA Astrophysics Data System (ADS)

    Mach, Patryk; Xie, Naqing

    2017-10-01

    We investigate toroidal marginally outer trapped surfaces (MOTS) and marginally outer trapped tubes (MOTT) in closed Friedmann-Lemaître-Robertson-Walker (FLRW) geometries. They are constructed by embedding constant mean curvature (CMC) Clifford tori in a FLRW spacetime. This construction is used to assess the quality of certain isoperimetric inequalities, recently proved in axial symmetry. Similarly to spherically symmetric MOTS existing in FLRW spacetimes, the toroidal ones are also unstable.

  4. Length of positive surgical margin after radical prostatectomy as a predictor of biochemical recurrence.

    PubMed

    Shikanov, Sergey; Song, Jie; Royce, Cassandra; Al-Ahmadie, Hikmat; Zorn, Kevin; Steinberg, Gary; Zagaja, Gregory; Shalhav, Arieh; Eggener, Scott

    2009-07-01

    Length and location of positive surgical margins are independent predictors of biochemical recurrence after open radical prostatectomy. We assessed their impact on biochemical recurrence in a large robotic prostatectomy series. Data were collected prospectively from 1,398 men undergoing robotic radical prostatectomy for clinically localized prostate cancer from 2003 to 2008 at a single institution. The associations of preoperative prostate specific antigen, pathological Gleason score, pathological stage and positive surgical margin parameters (location, length and focality) with biochemical recurrence rate were evaluated. Margin status and length were measured by a single uropathologist. Biochemical recurrence was defined as serum prostate specific antigen greater than 0.1 ng/ml on 2 consecutive tests. Cox regression models were constructed to evaluate predictors of biochemical recurrence. Of 1,398 consecutive patients who underwent robotic prostatectomy positive margins were present in 243 (17%) (11% of pathological T2 and 41% of T3). Preoperative prostate specific antigen, pathological stage, Gleason score, margin status, and margin length as a continuous and categorical variable (less than 1, 1 to 3, more than 3 mm) were independent predictors of biochemical recurrence. Patients with negative margins and those with a positive margin less than 1 mm had similar rates of biochemical recurrence (log rank test p = 0.18). Surgical margin location was not independently associated with biochemical recurrence. Margin status and length are independent predictors of biochemical recurrence following robotic radical prostatectomy. Although longer followup and validation studies are necessary for confirmation, patients with a positive margin less than 1 mm appear to have similar recurrence rates as those with negative margins.

  5. A Decision Support Framework for Evaluation of Engineered ...

    EPA Pesticide Factsheets

    Engineered nanomaterials (ENM) are currently being developed and applied at rates that far exceed our ability to evaluate their potential for environmental or human health risks. The gap between material development and capacity for assessment grows wider every day. Transformative approaches are required that enhance our ability to forecast potential exposure and adverse health risks based on limited information such as the physical and chemical parameters of ENM, their proposed uses, and functional assays reflective of key ENM - environmental interactions. We are developing a framework that encompasses the potential for release of nanomaterials across a product life cycle, environmental transport, transformations and fate, exposure to sensitive species, including humans, and the potential for causing adverse effects. Each component of the framework is conceive of as a sequential segmented model depicting the movement, transformations and actions of ENM through environmental or biological compartments, and along which targeted functional assays can be developed that are indicative of projected rates of ENM movement or action. The eventual goal is to allow simple predictive models to be built that incorporate the data from key functional assays and thereby allow rapid screening of the projected margin of exposure for proposed applications of ENM enabled products. In this way, cases where a substantially safe margin of exposure is forecast can be reduced in

  6. The influence of selection for vulnerability to angling on foraging ecology in largemouth bass Micropterus salmoides.

    PubMed

    Nannini, M A; Wahl, D H; Philipp, D P; Cooke, S J

    2011-10-01

    Several traits related to foraging behaviour were assessed in young-of-the-year produced from largemouth bass Micropterus salmoides that had been exposed to four generations of artificial selection for vulnerability to angling. As recreational angling may target foraging ability, this study tested the hypothesis that selection for vulnerability to angling would affect behaviours associated with foraging ecology and prey capture success. Fish selected for low vulnerability to angling captured more prey and attempted more captures than high vulnerability fish. The higher capture attempts, however, ultimately resulted in a lower capture success for low vulnerability fish. Low vulnerability fish also had higher prey rejection rates, marginally shorter reactive distance and were more efficient at converting prey consumed into growth than their high vulnerability counterparts. Selection due to recreational fishing has the potential to affect many aspects of the foraging ecology of the targeted population and highlights the importance of understanding evolutionary effects and how these need to be considered when managing populations. © 2011 The Authors. Journal of Fish Biology © 2011 The Fisheries Society of the British Isles.

  7. Automated Target Planning for FUSE Using the SOVA Algorithm

    NASA Technical Reports Server (NTRS)

    Heatwole, Scott; Lanzi, R. James; Civeit, Thomas; Calvani, Humberto; Kruk, Jeffrey W.; Suchkov, Anatoly

    2007-01-01

    The SOVA algorithm was originally developed under the Resilient Systems and Operations Project of the Engineering for Complex Systems Program from NASA s Aerospace Technology Enterprise as a conceptual framework to support real-time autonomous system mission and contingency management. The algorithm and its software implementation were formulated for generic application to autonomous flight vehicle systems, and its efficacy was demonstrated by simulation within the problem domain of Unmanned Aerial Vehicle autonomous flight management. The approach itself is based upon the precept that autonomous decision making for a very complex system can be made tractable by distillation of the system state to a manageable set of strategic objectives (e.g. maintain power margin, maintain mission timeline, and et cetera), which if attended to, will result in a favorable outcome. From any given starting point, the attainability of the end-states resulting from a set of candidate decisions is assessed by propagating a system model forward in time while qualitatively mapping simulated states into margins on strategic objectives using fuzzy inference systems. The expected return value of each candidate decision is evaluated as the product of the assigned value of the end-state with the assessed attainability of the end-state. The candidate decision yielding the highest expected return value is selected for implementation; thus, the approach provides a software framework for intelligent autonomous risk management. The name adopted for the technique incorporates its essential elements: Strategic Objective Valuation and Attainability (SOVA). Maximum value of the approach is realized for systems where human intervention is unavailable in the timeframe within which critical control decisions must be made. The Far Ultraviolet Spectroscopic Explorer (FUSE) satellite, launched in 1999, has been collecting science data for eight years.[1] At its beginning of life, FUSE had six gyros in two IRUs and four reaction wheels. Over time through various failures, the satellite has been left with one reaction wheel on the vehicle skew axis and two gyros. To remain operational, a control scheme has been implemented using the magnetic torque rods and the remaining momentum wheel.[2] As a consequence, there are attitude regions where there is insufficient torque authority to overcome environmental disturbances (e.g. gravity gradient torques). The situation is further complicated by the fact that these attitude regions shift inertially with time as the spacecraft moves through earth s magnetic field during the course of its orbit. Under these conditions, the burden of planning targets and target-to-target slew maneuvers has increased significantly since the beginning of the mission.[3] Individual targets must be selected so that the magnetic field remains roughly aligned with the skew wheel axis to provide enough control authority to the other two orthogonal axes. If the field moves too far away from the skew axis, the lack of control authority allows environmental torques to pull the satellite away from the target and can potentially cause it to tumble. Slew maneuver planning must factor the stability of targets at the beginning and end, and the torque authority at all points along the slew. Due to the time varying magnetic field geometry relative to any two inertial targets, small modifications in slew maneuver timing can make large differences in the achievability of a maneuver.

  8. Decentralizing conservation and diversifying livelihoods within Kanchenjunga Conservation Area, Nepal.

    PubMed

    Parker, Pete; Thapa, Brijesh; Jacob, Aerin

    2015-12-01

    To alleviate poverty and enhance conservation in resource dependent communities, managers must identify existing livelihood strategies and the associated factors that impede household access to livelihood assets. Researchers increasingly advocate reallocating management power from exclusionary central institutions to a decentralized system of management based on local and inclusive participation. However, it is yet to be shown if decentralizing conservation leads to diversified livelihoods within a protected area. The purpose of this study was to identify and assess factors affecting household livelihood diversification within Nepal's Kanchenjunga Conservation Area Project, the first protected area in Asia to decentralize conservation. We randomly surveyed 25% of Kanchenjunga households to assess household socioeconomic and demographic characteristics and access to livelihood assets. We used a cluster analysis with the ten most common income generating activities (both on- and off-farm) to group the strategies households use to diversify livelihoods, and a multinomial logistic regression to identify predictors of livelihood diversification. We found four distinct groups of household livelihood strategies with a range of diversification that directly corresponded to household income. The predictors of livelihood diversification were more related to pre-existing socioeconomic and demographic factors (e.g., more landholdings and livestock, fewer dependents, receiving remittances) than activities sponsored by decentralizing conservation (e.g., microcredit, training, education, interaction with project staff). Taken together, our findings indicate that without direct policies to target marginalized groups, decentralized conservation in Kanchenjunga will continue to exclude marginalized groups, limiting a household's ability to diversify their livelihood and perpetuating their dependence on natural resources. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Assessing Air Pollutant-Induced, Health-Related External Costs in the Context of Nonmarginal System Changes: A Review.

    PubMed

    Bachmann, Till M

    2015-08-18

    Marginal analysis is the usual approach to environmental economic assessment, for instance, of health-related external costs due to energy-associated air pollutant emissions. However, nonlinearity exists in all steps of their assessment, i.e., atmospheric dispersion, impact assessment, and monetary valuation. Dedicated assessments thus appear necessary when evaluating large systems or their changes such as in green accounting or the implications of economy-wide energy transitions. Corresponding approaches are reviewed. Tools already exist that allow assessing a marginal change (e.g., one power plant's emissions) for different background emission scenarios that merely need to be defined and implemented. When assessing nonmarginal changes, the top-down approach is considered obsolete, and four variants of the bottom-up approach with different application domains were identified. Variants 1 and 2 use precalculated external cost factors with different levels of sophistication, suitable for energy systems modeling, optimizing for social (i.e., private and external) costs. Providing more reliable results due to more detailed modeling, emission sources are assessed individually or jointly in variants 3 and 4, respectively. Aiming at considering nonlinearity more fully and simultaneously following marginal analysis principles, I propose a variant 3-based approach, subdividing an aggregate (i.e., a nonmarginal change) into several smaller changes. Its strengths and drawbacks, notably the associated effort, are discussed.

  10. Clinical outcome of dedifferentiated liposarcoma in the extremities: A retrospective case series of 7 patients.

    PubMed

    Kito, Munehisa; Yoshimura, Yasuo; Isobe, Ken'ichi; Aoki, Kaoru; Suzuki, Shuichiro; Tanaka, Atsushi; Okamoto, Masanori; Sano, Kenji; Kato, Hiroyuki

    2016-09-01

    Wide resection is the generally recommended surgical treatment for dedifferentiated liposarcoma (DDLPS) in the extremities. However, it may be appropriate to distinguish the surgical margin of low-grade atypical lipomatous tumor (ALT)/well-differentiated liposarcoma (WDLPS) area from the high-grade dedifferentiated area, because the low- and high-grade areas can be clearly separated, both radiologically and histologically. This study re-evaluated the details of surgical margin of DDLPS in the extremities, and aimed to investigate the optimal surgical margin and the usefulness of adjuvant therapy for DDLPS in the extremities. Seven patients diagnosed with DDLPS in the extremities and treated between 1995 and 2013 were analyzed. The use of adjuvant therapy before and after surgery was assessed, and the surgical margins for the ALT/WDLPS and dedifferentiated areas were re-evaluated by using the specimens resected at surgery. Subsequently, the recurrence rates, metastatic rates, and oncological outcomes were examined. Four and three patients had wide (adequate wide margin, n = 3; inadequate wide margin, n = 1) and marginal margins for the dedifferentiated area, respectively, while three and four patients had wide (adequate wide margin, n = 2; inadequate wide margin, n = 1) and marginal margins for the ALT/WDLPS area, respectively. Postoperative radiotherapy was performed in three patients with an inadequate wide margin or a marginal margin for the dedifferentiated area. No patient had local recurrence. Distant metastases occurred in two patients. These patients died of their disease. The other five patients were disease-free. The ALT/WDLPS and dedifferentiated areas in the tumor margin may be better to be considered separately in determining the appropriate resection extent for DDLPS in the extremities. Postoperative radiotherapy may provide good local control for cases with a narrow surgical margin. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  11. The assessment of mucosal surgical margins in head and neck cancer surgery with narrow band imaging.

    PubMed

    Šifrer, Robert; Urbančič, Jure; Strojan, Primož; Aničin, Aleksandar; Žargi, Miha

    2017-07-01

    The diagnostic gain of narrow band imaging in the definition of surgical margins in the treatment of head and neck cancer was evaluated. A prospective study, blinded to the pathologist, with historical comparison. The study group included 45 patients subjected to the intraoperative definition of margins by narrow band imaging. The control group included 55 patients who had undergone standard definition of margins. All patients underwent resection of the tumor and frozen section analysis of superficial margins. The rate of initial R 0 resection and the ratio of histologically negative margins for both groups were statistically compared. The rate of initial R 0 resection in the study group and in the control group was 88.9% and 70.9% (P = .047), and the ratio of histologically negative margins was 95.9% and 88.4% (P = .017), respectively. Narrow band imaging reveals a microscopic extension of the tumor that could be effectively used to better define superficial margins and to achieve a higher rate of initial R 0 resections. 4 Laryngoscope, 127:1577-1582, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  12. Three-dimensional and topographic relationships between the orbital margins with reference to assessment of eyeball protrusion.

    PubMed

    Shin, Kang-Jae; Lee, Shin-Hyo; Koh, Ki-Seok; Song, Wu-Chul

    2017-03-01

    This study investigated the topographic relationships among the eyeball and four orbital margins with the aim of identifying the correlation between orbital geometry and eyeball protrusion in Koreans. Three-dimensional (3D) volume rendering of the face was performed using serial computed-tomography images of 141 Koreans, and several landmarks on the bony orbit and the cornea were directly marked on the 3D volumes. The anterior-posterior distances from the apex of the cornea to each orbital margin and between the orbital margins were measured in both eyes. The distances from the apex of the cornea to the superior, medial, inferior, and lateral orbital margins were 5.8, 5.8, 12.0, and 17.9 mm, respectively. Differences between sides were observed in all of the orbital margins, and the distances from the apex of the cornea to the superior and inferior orbital margins were significantly greater in females than in males. The anterior-posterior distance between the superior and inferior orbital margins did not differ significantly between males (6.3 mm) and females (6.2 mm). The data obtained in this study will be useful when developing practical guidelines applicable to forensic facial reconstruction and orbitofacial surgeries.

  13. Chapter 27: Geology and petroleum potential of the north and east margins of the Siberian Craton, north of the Arctic Circle

    USGS Publications Warehouse

    Klett, T.R.; Wandrey, C.J.; Pitman, Janet K.

    2011-01-01

    The Siberian Craton consists of crystalline rocks and superimposed Precambrian sedimentary rocks deposited in rift basins. Palaeozoic rocks, mainly carbonates, were deposited along the margins of the craton to form an outwardly younger concentric pattern that underlies an outward-thickening Mesozoic sedimentary section. The north and east margins of the Siberian Craton subsequently became foreland basins created by compressional deformation during collision with other tectonic plates. The Tunguska Basin developed as a Palaeozoic rift/sag basin over Proterozoic rifts. The geological provinces along the north and east margins of the Siberian Craton are immature with respect to exploration, so exploration-history analysis alone cannot be used for assessing undiscovered petroleum resources. Therefore, other areas from around the world having greater petroleum exploration maturity and similar geological characteristics, and which have been previously assessed, were used as analogues to aid in this assessment. The analogues included those of foreland basins and rift/sag basins that were later subjected to compression. The US Geological Survey estimated the mean undiscovered, technically recoverable conventional petroleum resources to be approximately 28 billion barrels of oil equivalent, including approximately 8 billion barrels of crude oil, 103 trillion cubic feet of natural gas and 3 billion barrels of natural gas liquids. ?? 2011 The Geological Society of London.

  14. The margination propensity of spherical particles for vascular targeting in the microcirculation

    PubMed Central

    Gentile, Francesco; Curcio, Antonio; Indolfi, Ciro; Ferrari, Mauro; Decuzzi, Paolo

    2008-01-01

    The propensity of circulating particles to drift laterally towards the vessel walls (margination) in the microcirculation has been experimentally studied using a parallel plate flow chamber. Fluorescent polystyrene particles, with a relative density to water of just 50 g/cm3comparable with that of liposomal or polymeric nanoparticles used in drug delivery and bio-imaging, have been used with a diameter spanning over three order of magnitudes from 50 nm up to 10 μm. The number n∼s of particles marginating per unit surface have been measured through confocal fluorescent microscopy for a horizontal chamber, and the corresponding total volume V∼s of particles has been calculated. Scaling laws have been derived as a function of the particle diameter d. In horizontal capillaries, margination is mainly due to the gravitational force for particles with d > 200 nm and V∼s increases with d4; whereas for smaller particles V∼s increases with d3. In vertical capillaries, since the particles are heavier than the fluid they would tend to marginate towards the walls in downward flows and towards the center in upward flows, with V∼s increasing with d9/2. However, the margination in vertical capillaries is predicted to be much smaller than in horizontal capillaries. These results suggest that, for particles circulating in an external field of volume forces (gravitation or magnetic), the strategy of using larger particles designed to marginate and adhere firmly to the vascular walls under flow could be more effective than that of using particles sufficiently small (d < 200 nm) to hopefully cross a discontinuous endothelium. PMID:18702833

  15. Local Setup Reproducibility of the Spinal Column When Using Intensity-Modulated Radiation Therapy for Craniospinal Irradiation With Patient in Supine Position

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stoiber, Eva Maria, E-mail: eva.stoiber@med.uni-heidelberg.de; Department of Medical Physics, German Cancer Research Center, Heidelberg; Giske, Kristina

    Purpose: To evaluate local positioning errors of the lumbar spine during fractionated intensity-modulated radiotherapy of patients treated with craniospinal irradiation and to assess the impact of rotational error correction on these uncertainties for one patient setup correction strategy. Methods and Materials: 8 patients (6 adults, 2 children) treated with helical tomotherapy for craniospinal irradiation were retrospectively chosen for this analysis. Patients were immobilized with a deep-drawn Aquaplast head mask. Additionally to daily megavoltage control computed tomography scans of the skull, once-a-week positioning of the lumbar spine was assessed. Therefore, patient setup was corrected by a target point correction, derived frommore » a registration of the patient's skull. The residual positioning variations of the lumbar spine were evaluated applying a rigid-registration algorithm. The impact of different rotational error corrections was simulated. Results: After target point correction, residual local positioning errors of the lumbar spine varied considerably. Craniocaudal axis rotational error correction did not improve or deteriorate these translational errors, whereas simulation of a rotational error correction of the right-left and anterior-posterior axis increased these errors by a factor of 2 to 3. Conclusion: The patient fixation used allows for deformations between the patient's skull and spine. Therefore, for the setup correction strategy evaluated in this study, generous margins for the lumbar spinal target volume are needed to prevent a local geographic miss. With any applied correction strategy, it needs to be evaluated whether or not a rotational error correction is beneficial.« less

  16. Using a Marginal Structural Model to Design a Theory-Based Mass Media Campaign.

    PubMed

    Nishiuchi, Hiromu; Taguri, Masataka; Ishikawa, Yoshiki

    2016-01-01

    The essential first step in the development of mass media health campaigns is to identify specific beliefs of the target audience. The challenge is to prioritize suitable beliefs derived from behavioral theory. The purpose of this study was to identify suitable beliefs to target in a mass media campaign to change behavior using a new method to estimate the possible effect size of a small set of beliefs. Data were drawn from the 2010 Japanese Young Female Smoker Survey (n = 500), conducted by the Japanese Ministry of Health, Labor and Welfare. Survey measures included intention to quit smoking, psychological beliefs (attitude, norms, and perceived control) based on the theory of planned behavior and socioeconomic status (age, education, household income, and marital status). To identify suitable candidate beliefs for a mass media health campaign, we estimated the possible effect size required to change the intention to quit smoking among the population of young Japanese women using the population attributable fraction from a marginal structural model. Thirteen percent of study participants intended to quit smoking. The marginal structural model estimated a population attributable fraction of 47 psychological beliefs (21 attitudes, 6 norms, and 19 perceived controls) after controlling for socioeconomic status. The belief, "I could quit smoking if my husband or significant other recommended it" suggested a promising target for a mass media campaign (population attributable fraction = 0.12, 95% CI = 0.02-0.23). Messages targeting this belief could possibly improve intention rates by up to 12% among this population. The analysis also suggested the potential for regulatory action. This study proposed a method by which campaign planners can develop theory-based mass communication strategies to change health behaviors at the population level. This method might contribute to improving the quality of future mass health communication strategies and further research is needed.

  17. Continuous monitoring and intrafraction target position correction during treatment improves target coverage for patients undergoing SBRT prostate therapy.

    PubMed

    Lovelock, D Michael; Messineo, Alessandra P; Cox, Brett W; Kollmeier, Marisa A; Zelefsky, Michael J

    2015-03-01

    To compare the potential benefits of continuous monitoring of prostate position and intervention (CMI) using 2-mm displacement thresholds during stereotactic body radiation therapy (SBRT) treatment to those of a conventional image-guided procedure involving single localization prior to treatment. Eighty-nine patients accrued to a prostate SBRT dose escalation protocol were implanted with radiofrequency transponder beacons. The planning target volume (PTV) margin was 5 mm in all directions, except for 3 mm in the posterior direction. The prostate was kept within 2 mm of its planned position by the therapists halting dose delivery and, if necessary, correcting the couch position. We computed the number, type, and time required for interventions and where the prostate would have been during dose delivery had there been, instead, a single image-guided setup procedure prior to each treatment. Distributions of prostate displacements were computed as a function of time. After the initial setup, 1.7 interventions per fraction were required, with a concomitant increase in time for dose delivery of approximately 65 seconds. Small systematic drifts in prostate position in the posterior and inferior directions were observed in the study patients. Without CMI, intrafractional motion would have resulted in approximately 10% of patients having a delivered dose that did not meet our clinical coverage requirement, that is, a PTV D95 of >90%. The posterior PTV margin required for 95% of the dose to be delivered with the target positioned within the PTV was computed as a function of time. The margin necessary was found to increase by 2 mm every 5 minutes, starting from the time of the imaging procedure. CMI using a tight 2-mm displacement threshold was not only feasible but was found to deliver superior PTV coverage compared with the conventional image-guided procedure in the SBRT setting. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Continuous Monitoring and Intrafraction Target Position Correction During Treatment Improves Target Coverage for Patients Undergoing SBRT Prostate Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lovelock, D. Michael, E-mail: lovelocm@mskcc.org; Messineo, Alessandra P.; Cox, Brett W.

    2015-03-01

    Purpose: To compare the potential benefits of continuous monitoring of prostate position and intervention (CMI) using 2-mm displacement thresholds during stereotactic body radiation therapy (SBRT) treatment to those of a conventional image-guided procedure involving single localization prior to treatment. Methods and Materials: Eighty-nine patients accrued to a prostate SBRT dose escalation protocol were implanted with radiofrequency transponder beacons. The planning target volume (PTV) margin was 5 mm in all directions, except for 3 mm in the posterior direction. The prostate was kept within 2 mm of its planned position by the therapists halting dose delivery and, if necessary, correcting themore » couch position. We computed the number, type, and time required for interventions and where the prostate would have been during dose delivery had there been, instead, a single image-guided setup procedure prior to each treatment. Distributions of prostate displacements were computed as a function of time. Results: After the initial setup, 1.7 interventions per fraction were required, with a concomitant increase in time for dose delivery of approximately 65 seconds. Small systematic drifts in prostate position in the posterior and inferior directions were observed in the study patients. Without CMI, intrafractional motion would have resulted in approximately 10% of patients having a delivered dose that did not meet our clinical coverage requirement, that is, a PTV D95 of >90%. The posterior PTV margin required for 95% of the dose to be delivered with the target positioned within the PTV was computed as a function of time. The margin necessary was found to increase by 2 mm every 5 minutes, starting from the time of the imaging procedure. Conclusions: CMI using a tight 2-mm displacement threshold was not only feasible but was found to deliver superior PTV coverage compared with the conventional image-guided procedure in the SBRT setting.« less

  19. Using a Marginal Structural Model to Design a Theory-Based Mass Media Campaign

    PubMed Central

    Taguri, Masataka; Ishikawa, Yoshiki

    2016-01-01

    Background The essential first step in the development of mass media health campaigns is to identify specific beliefs of the target audience. The challenge is to prioritize suitable beliefs derived from behavioral theory. The purpose of this study was to identify suitable beliefs to target in a mass media campaign to change behavior using a new method to estimate the possible effect size of a small set of beliefs. Methods Data were drawn from the 2010 Japanese Young Female Smoker Survey (n = 500), conducted by the Japanese Ministry of Health, Labor and Welfare. Survey measures included intention to quit smoking, psychological beliefs (attitude, norms, and perceived control) based on the theory of planned behavior and socioeconomic status (age, education, household income, and marital status). To identify suitable candidate beliefs for a mass media health campaign, we estimated the possible effect size required to change the intention to quit smoking among the population of young Japanese women using the population attributable fraction from a marginal structural model. Results Thirteen percent of study participants intended to quit smoking. The marginal structural model estimated a population attributable fraction of 47 psychological beliefs (21 attitudes, 6 norms, and 19 perceived controls) after controlling for socioeconomic status. The belief, “I could quit smoking if my husband or significant other recommended it” suggested a promising target for a mass media campaign (population attributable fraction = 0.12, 95% CI = 0.02–0.23). Messages targeting this belief could possibly improve intention rates by up to 12% among this population. The analysis also suggested the potential for regulatory action. Conclusions This study proposed a method by which campaign planners can develop theory-based mass communication strategies to change health behaviors at the population level. This method might contribute to improving the quality of future mass health communication strategies and further research is needed. PMID:27441626

  20. Maintenance of marginal bone support and soft tissue esthetics at immediately provisionalized OsseoSpeed implants placed into extraction sites: 2-year results.

    PubMed

    Noelken, Robert; Neffe, Bettina Anna; Kunkel, Martin; Wagner, Wilfried

    2014-02-01

    Placement of implants into extraction sockets targets the maintenance of peri-implant hard and soft tissue structures and the support of a natural and esthetic contour. The main advantages of immediate implant insertion in comparison with delayed implant placement protocols are as follows: a reduced treatment time, less number of sessions, and, thus, the less invasive procedure. This study examines the clinical performance (survival rate, marginal bone levels and Pink Esthetic Score [PES]) of OsseoSpeed implants placed into extraction sockets with immediate provisionalization in the anterior maxilla after a follow-up of at least 12 months. Twenty patients received a total number of 37 OsseoSpeed implants which were immediately inserted into extraction sockets with or without facial bone deficiencies of various dimensions. A flapless procedure was applied, and the implants were immediately provisionalized with temporary crowns without occlusal contacts. Facial gaps between implant surface and facial bone or the previous contour of the alveolar process were grafted with autogenous bone chips. Implants in diameters 3.5, 4.0, 4.5, and 5.0 with lengths of 11-17 mm were used in the study. During the course of the study, interproximal marginal bone levels, the thickness of the facial bony wall, implant success rate according to the criteria established by Buser, and the PES were assessed per implant. One patient with three implants did not continue the study after prosthesis delivery, the remaining 34 implants were still in function at the final follow-up (survival rate: 100%). The mean follow-up period was 27 months (range, 12-40 months). Marginal bone height at the level of the implant shoulder averaged -0.1 ± 0.55 mm (range, -1.25 to 1.47 mm) at the final follow-up. The mean PES ratings were 11.3 ± 1.8 (range, 6-14) at the final follow-up. In 78% of the patients, the PES was preserved or even improved. Success rates, marginal bone levels, and esthetic results suggest proof of principle for the preservation of marginal bone height at immediately placed and provisionalized OsseoSpeed implants after a follow-up of at least 12 months. Even implant sites with facial bony deficiencies can be successfully treated with a favorable esthetic outcome using the immediate implant insertion, immediate reconstruction, and immediate provisionalization technique. © 2013 John Wiley & Sons A/S.

  1. Beyond the "I" in the obesity epidemic: a review of social relational and network interventions on obesity.

    PubMed

    Leroux, Janette S; Moore, Spencer; Dubé, Laurette

    2013-01-01

    Recent research has shown the importance of networks in the spread of obesity. Yet, the translation of research on social networks and obesity into health promotion practice has been slow. To review the types of obesity interventions targeting social relational factors. Six databases were searched in January 2013. A Boolean search was employed with the following sets of terms: (1) social dimensions: social capital, cohesion, collective efficacy, support, social networks, or trust; (2) intervention type: intervention, experiment, program, trial, or policy; and (3) obesity in the title or abstract. Titles and abstracts were reviewed. Articles were included if they described an obesity intervention with the social relational component central. Articles were assessed on the social relational factor(s) addressed, social ecological level(s) targeted, the intervention's theoretical approach, and the conceptual placement of the social relational component in the intervention. Database searches and final article screening yielded 30 articles. Findings suggested that (1) social support was most often targeted; (2) few interventions were beyond the individual level; (3) most interventions were framed on behaviour change theories; and (4) the social relational component tended to be conceptually ancillary to the intervention. Theoretically and practically, social networks remain marginal to current interventions addressing obesity.

  2. Multi-atlas segmentation for abdominal organs with Gaussian mixture models

    NASA Astrophysics Data System (ADS)

    Burke, Ryan P.; Xu, Zhoubing; Lee, Christopher P.; Baucom, Rebeccah B.; Poulose, Benjamin K.; Abramson, Richard G.; Landman, Bennett A.

    2015-03-01

    Abdominal organ segmentation with clinically acquired computed tomography (CT) is drawing increasing interest in the medical imaging community. Gaussian mixture models (GMM) have been extensively used through medical segmentation, most notably in the brain for cerebrospinal fluid / gray matter / white matter differentiation. Because abdominal CT exhibit strong localized intensity characteristics, GMM have recently been incorporated in multi-stage abdominal segmentation algorithms. In the context of variable abdominal anatomy and rich algorithms, it is difficult to assess the marginal contribution of GMM. Herein, we characterize the efficacy of an a posteriori framework that integrates GMM of organ-wise intensity likelihood with spatial priors from multiple target-specific registered labels. In our study, we first manually labeled 100 CT images. Then, we assigned 40 images to use as training data for constructing target-specific spatial priors and intensity likelihoods. The remaining 60 images were evaluated as test targets for segmenting 12 abdominal organs. The overlap between the true and the automatic segmentations was measured by Dice similarity coefficient (DSC). A median improvement of 145% was achieved by integrating the GMM intensity likelihood against the specific spatial prior. The proposed framework opens the opportunities for abdominal organ segmentation by efficiently using both the spatial and appearance information from the atlases, and creates a benchmark for large-scale automatic abdominal segmentation.

  3. Robust optimization in lung treatment plans accounting for geometric uncertainty.

    PubMed

    Zhang, Xin; Rong, Yi; Morrill, Steven; Fang, Jian; Narayanasamy, Ganesh; Galhardo, Edvaldo; Maraboyina, Sanjay; Croft, Christopher; Xia, Fen; Penagaricano, Jose

    2018-05-01

    Robust optimization generates scenario-based plans by a minimax optimization method to find optimal scenario for the trade-off between target coverage robustness and organ-at-risk (OAR) sparing. In this study, 20 lung cancer patients with tumors located at various anatomical regions within the lungs were selected and robust optimization photon treatment plans including intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were generated. The plan robustness was analyzed using perturbed doses with setup error boundary of ±3 mm in anterior/posterior (AP), ±3 mm in left/right (LR), and ±5 mm in inferior/superior (IS) directions from isocenter. Perturbed doses for D 99 , D 98 , and D 95 were computed from six shifted isocenter plans to evaluate plan robustness. Dosimetric study was performed to compare the internal target volume-based robust optimization plans (ITV-IMRT and ITV-VMAT) and conventional PTV margin-based plans (PTV-IMRT and PTV-VMAT). The dosimetric comparison parameters were: ITV target mean dose (D mean ), R 95 (D 95 /D prescription ), Paddick's conformity index (CI), homogeneity index (HI), monitor unit (MU), and OAR doses including lung (D mean , V 20 Gy and V 15 Gy ), chest wall, heart, esophagus, and maximum cord doses. A comparison of optimization results showed the robust optimization plan had better ITV dose coverage, better CI, worse HI, and lower OAR doses than conventional PTV margin-based plans. Plan robustness evaluation showed that the perturbed doses of D 99 , D 98 , and D 95 were all satisfied at least 99% of the ITV to received 95% of prescription doses. It was also observed that PTV margin-based plans had higher MU than robust optimization plans. The results also showed robust optimization can generate plans that offer increased OAR sparing, especially for normal lungs and OARs near or abutting the target. Weak correlation was found between normal lung dose and target size, and no other correlation was observed in this study. © 2018 University of Arkansas for Medical Sciences. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  4. Evaluation of marginal fit of two all-ceramic copings with two finish lines

    PubMed Central

    Subasi, Gulce; Ozturk, Nilgun; Inan, Ozgur; Bozogullari, Nalan

    2012-01-01

    Objectives: This in-vitro study investigated the marginal fit of two all-ceramic copings with 2 finish line designs. Methods: Forty machined stainless steel molar die models with two different margin designs (chamfer and rounded shoulder) were prepared. A total of 40 standardized copings were fabricated and divided into 4 groups (n=10 for each finish line-coping material). Coping materials tested were IPS e.max Press and Zirkonzahn; luting agent was Variolink II. Marginal fit was evaluated after cementation with a stereomicroscope (Leica MZ16). Two-way analysis of variance and Tukey-HSD test were performed to assess the influence of each finish line design and ceramic type on the marginal fit of 2 all-ceramic copings (α =.05). Results: Two-way analysis of variance revealed no statistically significant differences for marginal fit relative to finish lines (P=.362) and ceramic types (P=.065). Conclusion: Within the limitations of this study, both types of all-ceramic copings demonstrated that the mean marginal fit was considered acceptable for clinical application (⩽120 μm). PMID:22509119

  5. On the Performance of the Marginal Homogeneity Test to Detect Rater Drift.

    PubMed

    Sgammato, Adrienne; Donoghue, John R

    2018-06-01

    When constructed response items are administered repeatedly, "trend scoring" can be used to test for rater drift. In trend scoring, raters rescore responses from the previous administration. Two simulation studies evaluated the utility of Stuart's Q measure of marginal homogeneity as a way of evaluating rater drift when monitoring trend scoring. In the first study, data were generated based on trend scoring tables obtained from an operational assessment. The second study tightly controlled table margins to disentangle certain features present in the empirical data. In addition to Q , the paired t test was included as a comparison, because of its widespread use in monitoring trend scoring. Sample size, number of score categories, interrater agreement, and symmetry/asymmetry of the margins were manipulated. For identical margins, both statistics had good Type I error control. For a unidirectional shift in margins, both statistics had good power. As expected, when shifts in the margins were balanced across categories, the t test had little power. Q demonstrated good power for all conditions and identified almost all items identified by the t test. Q shows substantial promise for monitoring of trend scoring.

  6. Whipple Resection: Concordance Between Frozen Section And Permanent Section Diagnosis Of Surgical Margins.

    PubMed

    Bilal, Muhammad; Tariq, Hina; Mamoon, Nadira

    2018-01-01

    Margin assessment is done in Whipple procedures which are usually performed to resect tumours of head of pancreas and ampullary/periampullary region. Aims and objective of the study are to determine the concordance between frozen sections (FS) and permanent sections (PS) of surgical margins in Whipple resections. It is a retrospective study, from January 2008 to January 2015 (07 years). It includes the specimen with malignancy in final report and for which FS of pancreatic and/or CBD margin(s) were requested. Data was retrieved from Laboratory information system (LIS) database. Of the 41 bile duct margins in cases of ampullary tumours, 03 were positive on FS as well as PS, 35 were negative on FS as well as on PS. Results showed 100% sensitivity, 92.1% specificity, 50% PPV and 100% NPV. Results of 36 pancreatic margins in cases of ampullary showed 100% sensitivity, 97.1% specificity, 50% PPV and 100% NPV. In pancreatic carcinoma cases, none of CBD margins were reported as positive on FS, 02 margins reported as negative were found positive on PS, while 17 were negative on FS as well as PS. Results showed 100% specificity and 89.5% NPV. Of the 27 pancreatic margins tested in pancreatic tumours 100% sensitivity, 94.1% specificity, 88.9% PPV and 100% NPV was found. Factors such as absent prior tissue diagnosis and/or inflammatory processes make margin diagnosis difficult. However, a high concordance was observed between our FS and PS diagnosis.

  7. Assessment and quantification of patient set-up errors in nasopharyngeal cancer patients and their biological and dosimetric impact in terms of generalized equivalent uniform dose (gEUD), tumour control probability (TCP) and normal tissue complication probability (NTCP)

    PubMed Central

    Marcie, S; Fellah, M; Chami, S; Mekki, F

    2015-01-01

    Objective: The aim of this study is to assess and quantify patients' set-up errors using an electronic portal imaging device and to evaluate their dosimetric and biological impact in terms of generalized equivalent uniform dose (gEUD) on predictive models, such as the tumour control probability (TCP) and the normal tissue complication probability (NTCP). Methods: 20 patients treated for nasopharyngeal cancer were enrolled in the radiotherapy–oncology department of HCA. Systematic and random errors were quantified. The dosimetric and biological impact of these set-up errors on the target volume and the organ at risk (OARs) coverage were assessed using calculation of dose–volume histogram, gEUD, TCP and NTCP. For this purpose, an in-house software was developed and used. Results: The standard deviations (1SDs) of the systematic set-up and random set-up errors were calculated for the lateral and subclavicular fields and gave the following results: ∑ = 0.63 ± (0.42) mm and σ = 3.75 ± (0.79) mm, respectively. Thus a planning organ at risk volume (PRV) margin of 3 mm was defined around the OARs, and a 5-mm margin used around the clinical target volume. The gEUD, TCP and NTCP calculations obtained with and without set-up errors have shown increased values for tumour, where ΔgEUD (tumour) = 1.94% Gy (p = 0.00721) and ΔTCP = 2.03%. The toxicity of OARs was quantified using gEUD and NTCP. The values of ΔgEUD (OARs) vary from 0.78% to 5.95% in the case of the brainstem and the optic chiasm, respectively. The corresponding ΔNTCP varies from 0.15% to 0.53%, respectively. Conclusion: The quantification of set-up errors has a dosimetric and biological impact on the tumour and on the OARs. The developed in-house software using the concept of gEUD, TCP and NTCP biological models has been successfully used in this study. It can be used also to optimize the treatment plan established for our patients. Advances in knowledge: The gEUD, TCP and NTCP may be more suitable tools to assess the treatment plans before treating the patients. PMID:25882689

  8. Marginal revenue and length of stay in inpatient psychiatry.

    PubMed

    Pletscher, Mark

    2016-09-01

    This study examines the changes in marginal revenue during psychiatric inpatient stays in a large Swiss psychiatric hospital after the introduction of a mixed reimbursement system with tariff rates that vary over length of stay. A discrete time duration model with a difference-in-difference specification and time-varying coefficients is estimated to assess variations in policy effects over length of stay. Among patients whose costs are fully reimbursed by the mixed scheme, the model demonstrates a significant effect of marginal revenue on length of stay. No significant policy effects are found among patients for whom only health insurance rates are delivered as mixed tariffs and government contributions are made retrospectively. The results indicate that marginal revenue can affect length of stay in inpatient psychiatry facilities, but that the reduction in marginal revenue must be sufficiently large.

  9. Effects of online cone-beam computed tomography with active breath control in determining planning target volume during accelerated partial breast irradiation.

    PubMed

    Li, Y; Zhong, R; Wang, X; Ai, P; Henderson, F; Chen, N; Luo, F

    2017-04-01

    To test if active breath control during cone-beam computed tomography (CBCT) could improve planning target volume during accelerated partial breast radiotherapy for breast cancer. Patients who were more than 40 years old, underwent breast-conserving dissection and planned for accelerated partial breast irradiation, and with postoperative staging limited to T1-2 N0 M0, or postoperative staging T2 lesion no larger than 3cm with a negative surgical margin greater than 2mm were enrolled. Patients with lobular carcinoma or extensive ductal carcinoma in situ were excluded. CBCT images were obtained pre-correction, post-correction and post-treatment. Set-up errors were recorded at left-right, anterior-posterior and superior-inferior directions. The differences between these CBCT images, as well as calculated radiation doses, were compared between patients with active breath control or free breathing. Forty patients were enrolled, among them 25 had active breath control. A total of 836 CBCT images were obtained for analysis. CBCT significantly reduced planning target volume. However, active breath control did not show significant benefit in decreasing planning target volume margin and the doses of organ-at-risk when compared to free breathing. CBCT, but not active breath control, could reduce planning target volume during accelerated partial breast irradiation. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  10. Sealing of minimally invasive Class II fillings (slot) using an adhesive patch: sealant margin extension for prevention.

    PubMed

    Schmidlin, Patrick R; Seemann, Rainer; Filli, Tilla; Attin, Thomas; Imfeld, Thomas

    2007-01-01

    A laboratory study was performed to assess the potential of an adhesive patch to seal small, unbeveled, Class II, box-only (slot) composite fillings. After minimal access cavity preparation with an 80 pm diamond bur, 40 box-only Class II cavities were prepared mesially and distally in 20 extracted human molars using a u-shaped PCS insert (EMS). One cavity per tooth was adhesively filled with a hybrid composite material in one increment. A patch, acting as an adhesive matrice, was applied to the other cavity of each tooth to seal the restoration. The margin of the patch was located in areas easily accessible to oral hygiene measures and self-cleaning. All the teeth were subjected to thermo-mechanical stress in a computer-controlled masticator device. In 10 teeth, caries was induced in a microbial-based artificial mouth model and quantitatively determined by confocal laser scanning microscopy. Microleakage was assessed in the other 10 teeth in two planar sections after immersion in 0.5% basic fuchsin solution. The results showed no demineralization at the filling margins protected with the patch. Microleakage was observed in one sample only and was limited to the enamel. In contrast, the margins of fillings without the patch application showed a mean demineralization depth of 146 +/- 42 microm and dye penetration into the dentin in five sections. This innovative approach to sealing restorative margins with an adhesive patch results in less leakage and filling margin demineralization and merits further investigation.

  11. A 2-year integrated agriculture and nutrition and health behavior change communication program targeted to women in Burkina Faso reduces anemia, wasting, and diarrhea in children 3-12.9 months of age at baseline: a cluster-randomized controlled trial.

    PubMed

    Olney, Deanna K; Pedehombga, Abdoulaye; Ruel, Marie T; Dillon, Andrew

    2015-06-01

    Among young children in Burkina Faso, anemia and chronic and acute undernutrition are widespread. This study assessed the impact of Helen Keller International's (HKI) 2-y integrated agriculture [homestead food production (HFP)] and nutrition and health behavior change communication (BCC) program, targeted to women, on children's (3-12.9 mo old at baseline) anthropometry (stunting, wasting, and underweight), mean hemoglobin (Hb), anemia (Hb < 11 g/dL), and diarrhea prevalence. We used a cluster-randomized controlled trial, with 55 villages randomly assigned to a control group (n = 25) or 1 of 2 treatment groups (n = 15 each), which differed by who delivered the BCC messages [older women leaders or health committee (HC) members]. We used difference-in-difference (DID) estimates to assess impacts on child outcomes. We found marginally significant (P < 0.10) impacts on Hb (DID: 0.51 g/dL; P = 0.07) and wasting [DID: -8.8 percentage point (pp); P = 0.08] and statistically significant (P < 0.05) impacts on diarrhea (-15.9 pp; P = 0.00) in HC compared with control villages among children aged 3-12.9 mo and larger impacts for anemia (DID: -14.6 pp; P = 0.03) and mean Hb (DID: 0.74 g/dL; P = 0.03) among younger children (aged 3-5.9 mo). However, we found no significant impacts on stunting or underweight prevalence. Plausibility was supported by greater improvements in women's agricultural production and maternal infant and young child feeding and care knowledge and practices in HC compared with control villages. HKI's 2-y integrated HFP+BCC program (HC group) significantly improved several child outcomes, including wasting (marginal), diarrhea, Hb, and anemia, especially among the youngest children. This is the first cluster-randomized controlled trial of an HFP program that documents statistically significant positive effects on these child nutrition outcomes. This trial was registered at clinicaltrials.gov as NCT01825226. © 2015 American Society for Nutrition.

  12. Positioning accuracy during VMAT of gynecologic malignancies and the resulting dosimetric impact by a 6-degree-of-freedom couch in combination with daily kilovoltage cone beam computed tomography.

    PubMed

    Yao, Lihong; Zhu, Lihong; Wang, Junjie; Liu, Lu; Zhou, Shun; Jiang, ShuKun; Cao, Qianqian; Qu, Ang; Tian, Suqing

    2015-04-26

    To improve the delivery of radiotherapy in gynecologic malignancies and to minimize the irradiation of unaffected tissues by using daily kilovoltage cone beam computed tomography (kV-CBCT) to reduce setup errors. Thirteen patients with gynecologic cancers were treated with postoperative volumetric-modulated arc therapy (VMAT). All patients had a planning CT scan and daily CBCT during treatment. Automatic bone anatomy matching was used to determine initial inter-fraction positioning error. Positional correction on a six-degrees-of-freedom (6DoF) couch was followed by a second scan to calculate the residual inter-fraction error, and a post-treatment scan assessed intra-fraction motion. The margins of the planning target volume (MPTV) were calculated from these setup variations and the effect of margin size on normal tissue sparing was evaluated. In total, 573 CBCT scans were acquired. Mean absolute pre-/post-correction errors were obtained in all six planes. With 6DoF couch correction, the MPTV accounting for intra-fraction errors was reduced by 3.8-5.6 mm. This permitted a reduction in the maximum dose to the small intestine, bladder and femoral head (P=0.001, 0.035 and 0.032, respectively), the average dose to the rectum, small intestine, bladder and pelvic marrow (P=0.003, 0.000, 0.001 and 0.000, respectively) and markedly reduced irradiated normal tissue volumes. A 6DoF couch in combination with daily kV-CBCT can considerably improve positioning accuracy during VMAT treatment in gynecologic malignancies, reducing the MPTV. The reduced margin size permits improved normal tissue sparing and a smaller total irradiated volume.

  13. Implications of near-term coal power plant retirement for SO2 and NOX and life cycle GHG emissions.

    PubMed

    Venkatesh, Aranya; Jaramillo, Paulina; Griffin, W Michael; Matthews, H Scott

    2012-09-18

    Regulations monitoring SO(2), NO(X), mercury, and other metal emissions in the U.S. will likely result in coal plant retirement in the near-term. Life cycle assessment studies have previously estimated the environmental benefits of displacing coal with natural gas for electricity generation, by comparing systems that consist of individual natural gas and coal power plants. However, such system comparisons may not be appropriate to analyze impacts of coal plant retirement in existing power fleets. To meet this limitation, simplified economic dispatch models for PJM, MISO, and ERCOT regions are developed in this study to examine changes in regional power plant dispatch that occur when coal power plants are retired. These models estimate the order in which existing power plants are dispatched to meet electricity demand based on short-run marginal costs, with cheaper plants being dispatched first. Five scenarios of coal plant retirement are considered: retiring top CO(2) emitters, top NO(X) emitters, top SO(2) emitters, small and inefficient plants, and old and inefficient plants. Changes in fuel use, life cycle greenhouse gas emissions (including uncertainty), and SO(2) and NO(X) emissions are estimated. Life cycle GHG emissions were found to decrease by less than 4% in almost all scenarios modeled. In addition, changes in marginal damage costs due to SO(2), and NO(X) emissions are estimated using the county level marginal damage costs reported in the Air Pollution Emissions Experiments and Policy (APEEP) model, which are a proxy for measuring regional impacts of SO(2) and NO(X) emissions. Results suggest that location specific parameters should be considered within environmental policy frameworks targeting coal plant retirement, to account for regional variability in the benefits of reducing the impact of SO(2) and NO(X) emissions.

  14. Accuracy and Consistency of Respiratory Gating in Abdominal Cancer Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ge, Jiajia; Santanam, Lakshmi; Yang, Deshan

    2013-03-01

    Purpose: To evaluate respiratory gating accuracy and intrafractional consistency for abdominal cancer patients treated with respiratory gated treatment on a regular linear accelerator system. Methods and Materials: Twelve abdominal patients implanted with fiducials were treated with amplitude-based respiratory-gated radiation therapy. On the basis of daily orthogonal fluoroscopy, the operator readjusted the couch position and gating window such that the fiducial was within a setup margin (fiducial-planning target volume [f-PTV]) when RPM indicated “beam-ON.” Fifty-five pre- and post-treatment fluoroscopic movie pairs with synchronized respiratory gating signal were recorded. Fiducial motion traces were extracted from the fluoroscopic movies using a template matchingmore » algorithm and correlated with f-PTV by registering the digitally reconstructed radiographs with the fluoroscopic movies. Treatment was determined to be “accurate” if 50% of the fiducial area stayed within f-PTV while beam-ON. For movie pairs that lost gating accuracy, a MATLAB program was used to assess whether the gating window was optimized, the external-internal correlation (EIC) changed, or the patient moved between movies. A series of safety margins from 0.5 mm to 3 mm was added to f-PTV for reassessing gating accuracy. Results: A decrease in gating accuracy was observed in 44% of movie pairs from daily fluoroscopic movies of 12 abdominal patients. Three main causes for inaccurate gating were identified as change of global EIC over time (∼43%), suboptimal gating setup (∼37%), and imperfect EIC within movie (∼13%). Conclusions: Inconsistent respiratory gating accuracy may occur within 1 treatment session even with a daily adjusted gating window. To improve or maintain gating accuracy during treatment, we suggest using at least a 2.5-mm safety margin to account for gating and setup uncertainties.« less

  15. Assessing the Financial Condition of Provider-Sponsored Health Plans.

    PubMed

    McCue, Michael J

    2015-06-01

    The aim of this study was to assess the performance of health plans sponsored by provider organizations, with respect to plans generating strong positive cash flow relative to plans generating weaker cash flow. A secondary aim was to assess their capital adequacy. The study identified 24 provider-sponsored health plans (PSHPs) with an average positive cash flow margin from 2011 through 2013 at or above the top 75th percentile, defined as "strong cash flow PSHPs:" This group was compared with 72 PSHPs below the 75th percentile, defined as "weak cash flow PSHPs:" Atlantic Information Services Directory of Health Plans was used to identify the PSHPs. Financial ratios were computed from 2013 National Association of Insurance Commissioners Financial Filings. The study conducted a t test mean comparison between strong and weak cash flow PSHPs across an array of financial performance and capital adequacy measures. In 2013, the strong cash flow PSHPs averaged a cash-flow margin ratio of 6.6%. Weak cash flow PSHPs averaged a cash-flow margin of -0.4%. The net worth capital position of both groups was more than 4.5 times authorized capital. The operational analysis shows that strong cash-flow margin PSHPs are managing their medical costs to achieve this position. Although their medical loss ratio increased by almost 300 basis points from 2011 to 2013, it was still statistically significantly lower than the weaker cash flow PSHP group (P<.001). In terms of capital adequacy, both strong and weak cash-flow margin PSHP groups possessed sufficient capital to ensure the viability of these plans.

  16. [Spatio-temporal distribution of carabids and spiders between semi-natural field margin and the adjacent crop fields in agricultural landscape].

    PubMed

    Zhang, Xu Zhu; Han, Yin; Yu, Zhen Rong; Liu, Yun Hui

    2017-06-18

    This study was conducted before and after harvesting of wheat and maize in a typical agricultural landscape of the North China Plain. We investigated the diversity of two important natural enemy groups, carabids and spiders, using pitfall traps at crop field margin with different vegetation structures and their neighboring crop field. Throughout the comparison of the spatial and temporal distribution of the diversity of carabids and spiders in field margin and neighboring field, and the investigation of the relationship between arthropod communities and vegetation structure, this study aimed to understand the role of semi-natural field margin in biodiversity conservation of different natural enemy taxa. Results showed that the abundance of spiders was significantly higher in field margin than in neighboring fields over the entire period. No significant difference of the diversity of carabids in field margin and crop field was observed, but the community composition was different. Number of spider families increased in field margin but deceased in crop field after harvesting, indicating a migration activity between field and field margin. Vegetation structure in the field margin had different association with carabids than with spiders, with diversity of dominant carabid species positively associated with herb coverage and negatively with wood coverage, while the diversity of spider family Linyphiidae was positively associated with herb coverage only. Semi-natural habitat benefited the conservation of the diversity of arthropod natural enemies in crop field via promoting their dispersal to crop field, while such impacts differed from different vegetation structures and varied from target beneficial natural enemy communities. Future studies should focus on in-depth understanding of the food and habitat source requirement of different natural enemy taxa, and hence to design suitable semi-natural habitats to maintain a high diversity of natural enemy communities.

  17. Evaluation of overall setup accuracy and adequate setup margins in pelvic image-guided radiotherapy: Comparison of the male and female patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laaksomaa, Marko, E-mail: marko.laaksomaa@pshp.fi; Kapanen, Mika; Department of Medical Physics, Tampere University Hospital

    We evaluated adequate setup margins for the radiotherapy (RT) of pelvic tumors based on overall position errors of bony landmarks. We also estimated the difference in setup accuracy between the male and female patients. Finally, we compared the patient rotation for 2 immobilization devices. The study cohort included consecutive 64 male and 64 female patients. Altogether, 1794 orthogonal setup images were analyzed. Observer-related deviation in image matching and the effect of patient rotation were explicitly determined. Overall systematic and random errors were calculated in 3 orthogonal directions. Anisotropic setup margins were evaluated based on residual errors after weekly image guidance.more » The van Herk formula was used to calculate the margins. Overall, 100 patients were immobilized with a house-made device. The patient rotation was compared against 28 patients immobilized with CIVCO's Kneefix and Feetfix. We found that the usually applied isotropic setup margin of 8 mm covered all the uncertainties related to patient setup for most RT treatments of the pelvis. However, margins of even 10.3 mm were needed for the female patients with very large pelvic target volumes centered either in the symphysis or in the sacrum containing both of these structures. This was because the effect of rotation (p ≤ 0.02) and the observer variation in image matching (p ≤ 0.04) were significantly larger for the female patients than for the male patients. Even with daily image guidance, the required margins remained larger for the women. Patient rotations were largest about the lateral axes. The difference between the required margins was only 1 mm for the 2 immobilization devices. The largest component of overall systematic position error came from patient rotation. This emphasizes the need for rotation correction. Overall, larger position errors and setup margins were observed for the female patients with pelvic cancer than for the male patients.« less

  18. Development of the Final Version of the Classification and Assessment of Occupational Dysfunction Scale

    PubMed Central

    Teraoka, Mutsumi; Kyougoku, Makoto

    2015-01-01

    Occupational therapy is involved in disability prevention and health enhancement through the prevention of occupational dysfunction. Although many occupational dysfunction scales exist, no standard method is available for the assessment and classification of occupational dysfunction, which may include occupational imbalance, occupational deprivation, occupational alienation, and occupational marginalization. The purpose of this study was to develop the final version of Classification and Assessment of Occupational Dysfunction (CAOD). Our study demonstrated the validity and reliability of CAOD in a group of undergraduate students. The CAOD scale includes 16 items and addresses the following 4 domains: occupational imbalance, occupational deprivation, occupational alienation, and occupational marginalization. PMID:26263375

  19. Precessional control of Sr ratios in marginal basins during the Messinian Salinity Crisis?

    NASA Astrophysics Data System (ADS)

    Topper, R. P. M.; Lugli, S.; Manzi, V.; Roveri, M.; Meijer, P. Th.

    2014-05-01

    Based on 87Sr/86Sr data of the Primary Lower Gypsum (PLG) deposits in the Vena del Gesso basin—a marginal basin of the Mediterranean during the Messinian Salinity Crisis—a correlation between 87Sr/86Sr values and precessional forcing has recently been proposed but not yet confirmed. In this study, a box model is set up to represent the Miocene Mediterranean deep basin and a connected marginal basin. Measurements of 87Sr/86Sr in the Vena del Gesso and estimated salinity extrema are used to constrain model results. In an extensive analysis with this model, we assess whether coeval 87Sr/86Sr and salinity fluctuations could have been forced by precession-driven changes in the fresh water budget. A comprehensive set of the controlling parameters is examined to assess the conditions under which precession-driven 87Sr/86Sr variations occur and to determine the most likely setting for PLG formation. Model results show that precession-driven 87Sr/86Sr and salinity fluctuations in marginal basins are produced in settings within a large range of marginal basin sizes, riverine strontium characteristics, amplitudes of precessional fresh water budget variation, and average fresh water budgets of both the marginal and deep basin. PLG deposition most likely occurred when the Atlantic-Mediterranean connection was restricted, and the average fresh water budget in the Mediterranean was significantly less negative than at present day. Considering the large range of settings in which salinities and 87Sr/86Sr fluctuate on a precessional timescale, 87Sr/86Sr variations are expected to be a common feature in PLG deposits in marginal basins of the Mediterranean.

  20. Pre-operative assessment of residual disease in locally advanced breast cancer patients: A sequential study by quantitative diffusion weighted MRI as a function of therapy.

    PubMed

    Agarwal, Khushbu; Sharma, Uma; Sah, Rani G; Mathur, Sandeep; Hari, Smriti; Seenu, Vurthaluru; Parshad, Rajinder; Jagannathan, Naranamangalam R

    2017-10-01

    The potential of diffusion weighted imaging (DWI) in assessing pathologic response and surgical margins in locally advanced breast cancer patients (n=38) undergoing neoadjuvant chemotherapy was investigated. DWI was performed at pre-therapy (Tp0), after I (Tp1) and III (Tp3) NACT at 1.5T. Apparent diffusion coefficient (ADC) of whole tumor (ADC WT ), solid tumor (ADC ST ), intra-tumoral necrosis (ADC Nec ) was determined. Further, ADC of 6 consecutive shells (5mm thickness each) including tumor margin to outside tumor margins (OM1 to OM5) was calculated and the data analyzed to define surgical margins. Of 38 patients, 6 were pathological complete responders (pCR), 19 partial responders (pPR) and 13 were non-responders (pNR). Significant increase was observed in ADC ST and ADC WT in pCR and pPR following therapy. Pre-therapy ADC was significantly lower in pCR compared to pPR and pNR indicating the heterogeneous nature of tumor which may affect drug perfusion and consequently the response. ADC of outside margins (OM1, OM2, and OM3) was significantly different among pCR, pPR and pNR at Tp3 which may serve as response predictive parameter. Further, at Tp3, ADC of outside margins (OM1, OM2, and OM3) was significantly lower compared to that seen at Tp0 in pCR, indicating the presence of residual disease in these shells. Pre-surgery information may serve as a guide to define cancer free margins and the extent of residual disease which may be useful in planning breast conservation surgery. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Clearing margin system in the futures markets—Applying the value-at-risk model to Taiwanese data

    NASA Astrophysics Data System (ADS)

    Chiu, Chien-Liang; Chiang, Shu-Mei; Hung, Jui-Cheng; Chen, Yu-Lung

    2006-07-01

    This article sets out to investigate if the TAIFEX has adequate clearing margin adjustment system via unconditional coverage, conditional coverage test and mean relative scaled bias to assess the performance of three value-at-risk (VaR) models (i.e., the TAIFEX, RiskMetrics and GARCH-t). For the same model, original and absolute returns are compared to explore which can accurately capture the true risk. For the same return, daily and tiered adjustment methods are examined to evaluate which corresponds to risk best. The results indicate that the clearing margin adjustment of the TAIFEX cannot reflect true risks. The adjustment rules, including the use of absolute return and tiered adjustment of the clearing margin, have distorted VaR-based margin requirements. Besides, the results suggest that the TAIFEX should use original return to compute VaR and daily adjustment system to set clearing margin. This approach would improve the funds operation efficiency and the liquidity of the futures markets.

  2. SU-G-BRA-17: Tracking Multiple Targets with Independent Motion in Real-Time Using a Multi-Leaf Collimator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ge, Y; Keall, P; Poulsen, P

    Purpose: Multiple targets with large intrafraction independent motion are often involved in advanced prostate, lung, abdominal, and head and neck cancer radiotherapy. Current standard of care treats these with the originally planned fields, jeopardizing the treatment outcomes. A real-time multi-leaf collimator (MLC) tracking method has been developed to address this problem for the first time. This study evaluates the geometric uncertainty of the multi-target tracking method. Methods: Four treatment scenarios are simulated based on a prostate IMAT plan to treat a moving prostate target and static pelvic node target: 1) real-time multi-target MLC tracking; 2) real-time prostate-only MLC tracking; 3)more » correcting for prostate interfraction motion at setup only; and 4) no motion correction. The geometric uncertainty of the treatment is assessed by the sum of the erroneously underexposed target area and overexposed healthy tissue areas for each individual target. Two patient-measured prostate trajectories of average 2 and 5 mm motion magnitude are used for simulations. Results: Real-time multi-target tracking accumulates the least uncertainty overall. As expected, it covers the static nodes similarly well as no motion correction treatment and covers the moving prostate similarly well as the real-time prostate-only tracking. Multi-target tracking reduces >90% of uncertainty for the static nodal target compared to the real-time prostate-only tracking or interfraction motion correction. For prostate target, depending on the motion trajectory which affects the uncertainty due to leaf-fitting, multi-target tracking may or may not perform better than correcting for interfraction prostate motion by shifting patient at setup, but it reduces ∼50% of uncertainty compared to no motion correction. Conclusion: The developed real-time multi-target MLC tracking can adapt for the independently moving targets better than other available treatment adaptations. This will enable PTV margin reduction to minimize health tissue toxicity while remain tumor coverage when treating advanced disease with independently moving targets involved. The authors acknowledge funding support from the Australian NHMRC Australia Fellowship and NHMRC Project Grant No. APP1042375.« less

  3. A novel solid lipid nanoparticle formulation for active targeting to tumor α(v) β(3) integrin receptors reveals cyclic RGD as a double-edged sword.

    PubMed

    Shuhendler, Adam J; Prasad, Preethy; Leung, Michael; Rauth, Andrew M; Dacosta, Ralph S; Wu, Xiao Yu

    2012-09-01

    The overexpression of α(v) β(3) integrin receptors on tumor cells and tumor vascular endothelium makes it a useful target for imaging, chemotherapy and anti-angiogenic therapy. However integrin-targeted delivery of therapeutics by nanoparticles have provided only marginal, if any, enhancement of therapeutic effect. This work was thus focused on the development of novel α(v) β(3) -targeted near infrared light-emitting solid lipid nanoparticles (SLN) through conjugation to the α(v) β(3) integrin-specific ligand cyclic Arg-Gly-Asp (cRGD), and the assessment of the effects of α(v) β(3) targeting on nanoparticle biodistribution. Since our previously developed non-targeted "stealth" SLN showed little hepatic accumulation, unlike most reported liposomes and micelles, they served as a reference for quantifying the effects of cRGD-conjugation on tumor uptake and whole animal biodistribution of SLN. Non-targeted SLN, actively targeted (RGD-SLN) and blocked RGD-SLN were prepared to contain near infrared quantum dots for live animal imaging. They were injected intravenously to nude mice bearing xenograft orthotopic human breast tumors or dorsal window chamber breast tumors. Tumor micropharmacokinetics of various SLN formulations were determined using intravital microscopy, and whole animal biodistribution was followed over time by optical imaging. The active tumor targeting with cRGD was found to be a "double-edged sword": while the specificity of RGD-SLN accumulation in tumor blood vessels and their tumor residence time increased, their distribution in the liver, spleen, and kidneys was significantly greater than the non-targeted SLN, leaving a smaller amount of nanoparticles in the tumor tissue. Nevertheless the enhanced specificity and retention of RGD-SLN in tumor neovasculature could make this novel formulation useful for tumor neovascular-specific therapies and imaging applications. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Planning evaluation of radiotherapy for complex lung cancer cases using helical tomotherapy

    NASA Astrophysics Data System (ADS)

    Kron, Tomas; Grigorov, Grigor; Yu, Edward; Yartsev, Slav; Chen, Jeff Z.; Wong, Eugene; Rodrigues, George; Trenka, Kris; Coad, Terry; Bauman, Glenn; Van Dyk, Jake

    2004-08-01

    Lung cancer treatment is one of the most challenging fields in radiotherapy. The aim of the present study was to investigate what role helical tomotherapy (HT), a novel approach to the delivery of highly conformal dose distributions using intensity-modulated radiation fan beams, can play in difficult cases with large target volumes typical for many of these patients. Tomotherapy plans were developed for 15 patients with stage III inoperable non-small-cell lung cancer. While not necessarily clinically indicated, elective nodal irradiation was included for all cases to create the most challenging scenarios with large target volumes. A 2 cm margin was used around the gross tumour volume (GTV) to generate primary planning target volume (PTV2) and 1 cm margin around elective nodes for secondary planning target volume (PTV1) resulting in PTV1 volumes larger than 1000 cm3 in 13 of the 15 patients. Tomotherapy plans were created using an inverse treatment planning system (TomoTherapy Inc.) based on superposition/convolution dose calculation for a fan beam thickness of 25 mm and a pitch factor between 0.3 and 0.8. For comparison, plans were created using an intensity-modulated radiation therapy (IMRT) approach planned on a commercial treatment planning system (TheraplanPlus, Nucletron). Tomotherapy delivery times for the large target volumes were estimated to be between 4 and 19 min. Using a prescribed dose of 60 Gy to PTV2 and 46 Gy to PTV1, the mean lung dose was 23.8 ± 4.6 Gy. A 'dose quality factor' was introduced to correlate the plan outcome with patient specific parameters. A good correlation was found between the quality of the HT plans and the IMRT plans with HT being slightly better in most cases. The overlap between lung and PTV was found to be a good indicator of plan quality for HT. The mean lung dose was found to increase by approximately 0.9 Gy per percent overlap volume. Helical tomotherapy planning resulted in highly conformal dose distributions. It allowed easy achievement of two different dose levels in the target simultaneously. As the overlap between PTV and lung volume is a major predictor of mean lung dose, future work will be directed to control of margins. Work is underway to investigate the possibility of breath-hold techniques for tomotherapy delivery to facilitate this aim.

  5. Sustainable bioenergy production from marginal lands in the US Midwest.

    PubMed

    Gelfand, Ilya; Sahajpal, Ritvik; Zhang, Xuesong; Izaurralde, R César; Gross, Katherine L; Robertson, G Philip

    2013-01-24

    Legislation on biofuels production in the USA and Europe is directing food crops towards the production of grain-based ethanol, which can have detrimental consequences for soil carbon sequestration, nitrous oxide emissions, nitrate pollution, biodiversity and human health. An alternative is to grow lignocellulosic (cellulosic) crops on 'marginal' lands. Cellulosic feedstocks can have positive environmental outcomes and could make up a substantial proportion of future energy portfolios. However, the availability of marginal lands for cellulosic feedstock production, and the resulting greenhouse gas (GHG) emissions, remains uncertain. Here we evaluate the potential for marginal lands in ten Midwestern US states to produce sizeable amounts of biomass and concurrently mitigate GHG emissions. In a comparative assessment of six alternative cropping systems over 20 years, we found that successional herbaceous vegetation, once well established, has a direct GHG emissions mitigation capacity that rivals that of purpose-grown crops (-851 ± 46 grams of CO(2) equivalent emissions per square metre per year (gCO(2)e m(-2) yr(-1))). If fertilized, these communities have the capacity to produce about 63 ± 5 gigajoules of ethanol energy per hectare per year. By contrast, an adjacent, no-till corn-soybean-wheat rotation produces on average 41 ± 1 gigajoules of biofuel energy per hectare per year and has a net direct mitigation capacity of -397 ± 32 gCO(2)e m(-2) yr(-1); a continuous corn rotation would probably produce about 62 ± 7 gigajoules of biofuel energy per hectare per year, with 13% less mitigation. We also perform quantitative modelling of successional vegetation on marginal lands in the region at a resolution of 0.4 hectares, constrained by the requirement that each modelled location be within 80 kilometres of a potential biorefinery. Our results suggest that such vegetation could produce about 21 gigalitres of ethanol per year from around 11 million hectares, or approximately 25 per cent of the 2022 target for cellulosic biofuel mandated by the US Energy Independence and Security Act of 2007, with no initial carbon debt nor the indirect land-use costs associated with food-based biofuels. Other regional-scale aspects of biofuel sustainability, such as water quality and biodiversity, await future study.

  6. Using Logistic Approximations of Marginal Trace Lines to Develop Short Assessments

    ERIC Educational Resources Information Center

    Stucky, Brian D.; Thissen, David; Edelen, Maria Orlando

    2013-01-01

    Test developers often need to create unidimensional scales from multidimensional data. For item analysis, "marginal trace lines" capture the relation with the general dimension while accounting for nuisance dimensions and may prove to be a useful technique for creating short-form tests. This article describes the computations needed to obtain…

  7. The potential failure risk of the cone-beam computed tomography-based planning target volume margin definition for prostate image-guided radiotherapy based on a prospective single-institutional hybrid analysis.

    PubMed

    Hirose, Katsumi; Sato, Mariko; Hatayama, Yoshiomi; Kawaguchi, Hideo; Komai, Fumio; Sohma, Makoto; Obara, Hideki; Suzuki, Masashi; Tanaka, Mitsuki; Fujioka, Ichitaro; Ichise, Koji; Takai, Yoshihiro; Aoki, Masahiko

    2018-06-07

    The purpose of this study was to evaluate the impact of markerless on-board kilovoltage (kV) cone-beam computed tomography (CBCT)-based positioning uncertainty on determination of the planning target volume (PTV) margin by comparison with kV on-board imaging (OBI) with gold fiducial markers (FMs), and to validate a methodology for the evaluation of PTV margins for markerless kV-CBCT in prostate image-guided radiotherapy (IGRT). A total of 1177 pre- and 1177 post-treatment kV-OBI and 1177 pre- and 206 post-treatment kV-CBCT images were analyzed in 25 patients who received prostate IGRT with daily localization by implanted FMs. Intrafractional motion of the prostate was evaluated between each pre- and post-treatment image with these two different techniques. The differences in prostate deviations and intrafractional motions between matching by FM in kV-OBI (OBI-FM) and matching by soft tissues in kV-CBCT (CBCT-ST) were compared by Bland-Altman limits of agreement. Compensated PTV margins were determined and compensated by references. Mean differences between OBI-FM and CBCT-ST in the anterior to posterior (AP), superior to inferior (SI), and left to right (LR) directions were - 0.43 ± 1.45, - 0.09 ± 1.65, and - 0.12 ± 0.80 mm, respectively, with R 2  = 0.85, 0.88, and 0.83, respectively. Intrafractional motions obtained from CBCT-ST were 0.00 ± 1.46, 0.02 ± 1.49, and 0.15 ± 0.64 mm, respectively, which were smaller than the results from OBI-FM, with 0.43 ± 1.90, 0.12 ± 1.98, and 0.26 ± 0.80 mm, respectively, with R 2  = 0.42, 0.33, and 0.16, respectively. Bland-Altman analysis showed a significant proportional bias. PTV margins of 1.5 mm, 1.4 mm, and 0.9 mm for CBCT-ST were calculated from the values of CBCT-ST, which were also smaller than the values of 3.15 mm, 3.66 mm, and 1.60 mm from OBI-FM. The practical PTV margin for CBCT-ST was compensated with the values from OBI-FM as 4.1 mm, 4.8 mm, and 2.2 mm. PTV margins calculated from CBCT-ST might be underestimated compared to the true PTV margins. To determine a reliable CBCT-ST-based PTV margin, at least the systemic error Σ and the random error σ for on-line matching errors need to be investigated by supportive preliminary FM evaluation at least once.

  8. The scenario-based generalization of radiation therapy margins.

    PubMed

    Fredriksson, Albin; Bokrantz, Rasmus

    2016-03-07

    We give a scenario-based treatment plan optimization formulation that is equivalent to planning with geometric margins if the scenario doses are calculated using the static dose cloud approximation. If the scenario doses are instead calculated more accurately, then our formulation provides a novel robust planning method that overcomes many of the difficulties associated with previous scenario-based robust planning methods. In particular, our method protects only against uncertainties that can occur in practice, it gives a sharp dose fall-off outside high dose regions, and it avoids underdosage of the target in 'easy' scenarios. The method shares the benefits of the previous scenario-based robust planning methods over geometric margins for applications where the static dose cloud approximation is inaccurate, such as irradiation with few fields and irradiation with ion beams. These properties are demonstrated on a suite of phantom cases planned for treatment with scanned proton beams subject to systematic setup uncertainty.

  9. Adequate margins for random setup uncertainties in head-and-neck IMRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Astreinidou, Eleftheria; Bel, Arjan; Raaijmakers, Cornelis P.J.

    2005-03-01

    Purpose: To investigate the effect of random setup uncertainties on the highly conformal dose distributions produced by intensity-modulated radiotherapy (IMRT) for clinical head-and-neck cancer patients and to determine adequate margins to account for those uncertainties. Methods and materials: We have implemented in our clinical treatment planning system the possibility of simulating normally distributed patient setup displacements, translations, and rotations. The planning CT data of 8 patients with Stage T1-T3N0M0 oropharyngeal cancer were used. The clinical target volumes of the primary tumor (CTV{sub primary}) and of the lymph nodes (CTV{sub elective}) were expanded by 0.0, 1.5, 3.0, and 5.0 mm inmore » all directions, creating the planning target volumes (PTVs). We performed IMRT dose calculation using our class solution for each PTV margin, resulting in the conventional static plans. Then, the system recalculated the plan for each positioning displacement derived from a normal distribution with {sigma} = 2 mm and {sigma} = 4 mm (standard deviation) for translational deviations and {sigma} = 1 deg for rotational deviations. The dose distributions of the 30 fractions were summed, resulting in the actual plan. The CTV dose coverage of the actual plans was compared with that of the static plans. Results: Random translational deviations of {sigma} = 2 mm and rotational deviations of {sigma} = 1 deg did not affect the CTV{sub primary} volume receiving 95% of the prescribed dose (V{sub 95}) regardless of the PTV margin used. A V{sub 95} reduction of 3% and 1% for a 0.0-mm and 1.5-mm PTV margin, respectively, was observed for {sigma} = 4 mm. The V{sub 95} of the CTV{sub elective} contralateral was approximately 1% and 5% lower than that of the static plan for {sigma} = 2 mm and {sigma} = 4 mm, respectively, and for PTV margins < 5.0 mm. An additional reduction of 1% was observed when rotational deviations were included. The same effect was observed for the CTV{sub elective} ipsilateral but with smaller dose differences than those for the contralateral side. The effect of the random uncertainties on the mean dose to the parotid glands was not significant. The maximal dose to the spinal cord increased by a maximum of 3 Gy. Conclusions: The margins to account for random setup uncertainties, in our clinical IMRT solution, should be 1.5 mm and 3.0 mm in the case of {sigma} = 2 mm and {sigma} = 4 mm, respectively, for the CTV{sub primary}. Larger margins (5.0 mm), however, should be applied to the CTV{sub elective}, if the goal of treatment is a V{sub 95} value of at least 99%.« less

  10. More Accurate Definition of Clinical Target Volume Based on the Measurement of Microscopic Extensions of the Primary Tumor Toward the Uterus Body in International Federation of Gynecology and Obstetrics Ib-IIa Squamous Cell Carcinoma of the Cervix

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xie, Wen-Jia; Wu, Xiao; Xue, Ren-Liang

    Purpose: To more accurately define clinical target volume for cervical cancer radiation treatment planning by evaluating tumor microscopic extension toward the uterus body (METU) in International Federation of Gynecology and Obstetrics stage Ib-IIa squamous cell carcinoma of the cervix (SCCC). Patients and Methods: In this multicenter study, surgical resection specimens from 318 cases of stage Ib-IIa SCCC that underwent radical hysterectomy were included. Patients who had undergone preoperative chemotherapy, radiation, or both were excluded from this study. Microscopic extension of primary tumor toward the uterus body was measured. The association between other pathologic factors and METU was analyzed. Results: Microscopicmore » extension toward the uterus body was not common, with only 12.3% of patients (39 of 318) demonstrating METU. The mean (±SD) distance of METU was 0.32 ± 1.079 mm (range, 0-10 mm). Lymphovascular space invasion was associated with METU distance and occurrence rate. A margin of 5 mm added to gross tumor would adequately cover 99.4% and 99% of the METU in the whole group and in patients with lymphovascular space invasion, respectively. Conclusion: According to our analysis of 318 SCCC specimens for METU, using a 5-mm gross tumor volume to clinical target volume margin in the direction of the uterus should be adequate for International Federation of Gynecology and Obstetrics stage Ib-IIa SCCC. Considering the discrepancy between imaging and pathologic methods in determining gross tumor volume extent, we recommend a safer 10-mm margin in the uterine direction as the standard for clinical practice when using MRI for contouring tumor volume.« less

  11. Paired-agent imaging for resection during surgery (PAIRS) of head and neck squamous cell carcinomas (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Samkoe, Kimberley S.; Tichauer, Kenneth M.; Chen, Eunice; Gunn, Jason R.; Hoopes, P. Jack; Wells, Wendy A.; Hasan, Tayyaba; Pogue, Brian W.

    2016-03-01

    Ninety percent of patients with head and neck squamous cell carcinomas (HNSCC) have overexpression of epidermal growth factor receptor (EGFR), which is correlated with poor prognosis. Complete surgical resection of HNSCC tumors has a large impact on patient survival, where detection of tumor at or close to surgical margins increases the risk of death at 5-years by 90%. In addition, large surgical margins can greatly increase the morbidity experienced by the patient due to functional and cosmetic damage of oral and facial structures. Single fluorescence targeting agents are often used for tumor detection in in vivo pre-clinical imaging; however, the arising signal is qualitative at best because it is a complex mixture of vascular perfusion, vascular leakage, inhibited lymphatic clearance, and receptor binding. In vivo ratiometric receptor concentration imaging (RCI) allows quantification of receptor expression (hence identification of cancerous tissue) by utilizing co-administered paired-agents consisting of a targeted agent and non-targeted perfusion agent to reference the plasma delivery and leakage. A panel of HNSCC tumors with varying levels of EGFR expression (SCC-15 >SCC-25 > SCC-09) have been imaged using ABY-029, a clinically relevant anti-EGFR affibody labeled with IRDye 800CW, and affibody control imaging agent labeled with IRDye 680RD. RCI maps of in vivo tissue have been created and are spatially correlated with EGFR and CD31 immunohistochemistry and basic H and E staining. The RCI threshold parameters for distinguishing tumor from normal tissues (skin and muscle) and the accuracy of margin detection in these tumors will be presented. RCI surgical resection will be further developed using a novel multi-channel, gated fluorescence-guided surgery (FGS) imaging system that is capable of performing RCI in normal room light.

  12. A cone beam CT-Based Study for Clinical Target Definition Using Pelvic Anatomy During Postprostatectomy Radiotherapy.

    PubMed

    Showalter, Timothy N; Nawaz, A Omer; Xiao, Ying; Galvin, James M; Valicenti, Richard K

    2008-02-01

    There are no accepted guidelines for target volume definition for online image-guided radiation therapy (IGRT) after radical prostatectomy (RP). This study used cone beam CT (CBCT) imaging to generate information for use in post-RP IGRT. The pelvic anatomy of 10 prostate cancer patients undergoing post-RP radiation therapy (RT) to 68.4 Gy was studied using CBCT images obtained immediately before treatment. Contoured bladder and rectal volumes on CBCT images were compared with planning CT (CT(ref)) volumes from seminal vesicle stump (SVS) to bladder-urethral junction. This region was chosen to approximate the prostatic fossa (PF) during a course of post-RP RT. Anterior and posterior planning target volume margins were calculated using ICRU report 71 guidelines, accounting for systematic and random error based on bladder and rectal motion, respectively. A total of 176 CBCT study sets obtained 2 to 5 times weekly were analyzed. The rectal and bladder borders were reliably identified in 166 of 176 (94%) of CBCT images. Relative to CT(ref), mean posterior bladder wall position was anterior by 0.1 to 1.5 mm, and mean anterior rectum wall position was posterior by 1.6 to 2.7 mm. Calculated anterior margin as derived from bladder motion ranged from 5.9 to 7.1 mm. Calculated posterior margin as derived from rectal motion ranged from 8.6 to 10.2 mm. Normal tissue anatomy was definable by CBCT imaging throughout the course of post-RP RT, and the interfraction anteroposterior motion of the bladder and rectum was studied. This information should be considered in devising post-RP RT techniques using image guidance.

  13. Comparative evaluation of effects of bleaching on color stability and marginal adaptation of discolored direct and indirect composite laminate veneers under in vivo conditions.

    PubMed

    Jain, Veena; Das, Taposh K; Pruthi, Gunjan; Shah, Naseem; Rajendiran, Suresh

    2015-01-01

    Change in color and loss of marginal adaptation of tooth colored restorative materials is not acceptable. Bleaching is commonly used for treating discolored teeth. However, the literature is scanty regarding its effect on color and marginal adaptation of direct and indirect composite laminate veneers (CLVs) under in vivo conditions. Purpose of the study was to determine the effect of bleaching on color change and marginal adaptation of direct and indirect CLVs over a period of time when exposed to the oral environment. For this purpose, a total of 14 subjects irrespective of age and sex indicated for CLV restorations on maxillary anterior teeth were selected following the inclusion and exclusion criteria. For each subject, indirect CLVs were fabricated and looted in the first quadrant (Group 1) and direct CLV's (Group 2), were given in the second quadrant. Color change was assessed clinically using intra-oral digital spectrophotometer and marginal adaptation was assessed on epoxy resin replica of the tooth-restoration interface under scanning electron microscope. After 6 months, the subjects underwent a home bleaching regimen for 14 days using 10% carbamide peroxide. The assessment of color change and marginal adaptation was done at 6 months after veneering (0-180 days), immediately after the bleaching regimen (0-194 days) and 3 months after the bleaching regimen (0-284 days). The difference in median color change (ΔE) between the groups was tested using Wilcoxon rank sum test while the median color change with time within the groups was tested using Wilcoxon signed rank test. The difference in the rates of marginal adaptation was tested between the groups using Chi-square/Fisher's exact test. Bleaching led to statistically significant color change at cervical (CE), middle and incisal (IE) regions when direct and indirect composites were compared (P < 0.05). During intra-group comparison, direct CLV's showed significant color change at CE and IE regions when ΔE was compared at 180 days and 284 days (CE 10 vs. CE 30, P = 0.008, IE 10 vs. IE 30, P = 0.003). No significant differences were found when within group comparison was made for indirect laminates. Intergroup comparison between the groups showed significant difference in marginal adaptation at CE margin at all.time points (at baseline, P = 0.005; at 180 days, P = 0.007; 194 days, P = 0.025; at 284 days, P = 0.067). After bleaching, indirect CLVs performed better in terms of color stability whereas direct CLVs performed better in terms of marginal adaptation. Indirect composites should be preferred to direct composites as veneering materials as they have better color stability. Special attention should be given to their marginal adaptation especially in the CE region. Bleaching should be avoided in patients with composite restorations in the mouth.

  14. Evaluating deviations in prostatectomy patients treated with IMRT.

    PubMed

    Sá, Ana Cravo; Peres, Ana; Pereira, Mónica; Coelho, Carina Marques; Monsanto, Fátima; Macedo, Ana; Lamas, Adrian

    2016-01-01

    To evaluate the deviations in prostatectomy patients treated with IMRT in order to calculate appropriate margins to create the PTV. Defining inappropriate margins can lead to underdosing in target volumes and also overdosing in healthy tissues, increasing morbidity. 223 CBCT images used for alignment with the CT planning scan based on bony anatomy were analyzed in 12 patients treated with IMRT following prostatectomy. Shifts of CBCT images were recorded in three directions to calculate the required margin to create PTV. The mean and standard deviation (SD) values in millimetres were -0.05 ± 1.35 in the LR direction, -0.03 ± 0.65 in the SI direction and -0.02 ± 2.05 the AP direction. The systematic error measured in the LR, SI and AP direction were 1.35 mm, 0.65 mm, and 2.05 mm with a random error of 2.07 mm; 1.45 mm and 3.16 mm, resulting in a PTV margin of 4.82 mm; 2.64 mm, and 7.33 mm, respectively. With IGRT we suggest a margin of 5 mm, 3 mm and 8 mm in the LR, SI and AP direction, respectively, to PTV1 and PTV2. Therefore, this study supports an anisotropic margin expansion to the PTV being the largest expansion in the AP direction and lower in SI.

  15. WE-AB-207B-09: Margin Reduction for Planning Target Volume (PTV) in Patients with Localized Prostate Cancer: Impact On Delivered Dose and Quality of Life

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumarasiri, A; Liu, C; Brown, S

    Purpose: To estimate the delivered (cumulative) dose to targets and organs at risk for localized prostate cancer patients treated with reduced PTV margins and to evaluate preliminary patient reported quality-of-life (QOL). Methods: Under an IRB-approved protocol, 20 prostate cancer patients (including 11 control patients) were treated with reduced planning margins (5 mm uniform with 4 mm at prostate/rectum interface). Control patients had standard margin (10/6 mm)-based treatments. A parameter-optimized Elastix algorithm along with energy-mass mapping was used to deform and resample dose of the day onto the planning CT for each fraction to estimate the delivered dose over all fractions.more » QOL data were collected via Expanded Prostate cancer Index Composite (EPIC-26) questionnaires at time points pre-treatment, post-treatment, and at 2, 6, 12, 18 month follow-ups. Standardized QOL scores [range: 0–100] were determined and baseline-corrected by subtracting pre-treatment QOL data. Mean QOL differences between the margin reduced group and control group (QOLmr-QOLcontrol) were calculated for first 18 months. Results: The difference between the cumulative mean dose (Dmean) and the planned mean dose (±SD) for PTV, prostate, bladder, and rectum were −2.2±1.0, 0.3±0.5, −0.7±2.6, and −2.1±1.3 Gy respectively for the margin-reduced group, and −0.8±2.0, 0.9±1.4, - 0.7±3.1 and −1.0±2.4 Gy for the control group. Difference between the two groups was statistically insignificant (p=0.1). Standardized and baseline corrected QOLmr-QOLcontrol for EPIC domains categorized as “Urinary Incontinence”, “Urinary Irritative/Obstructive”, “Bowel”, “Sexual”, and “Hormonal” were 0.6, 12.1, 9.1, 13.3, and −0.9 for the 18 months following radiation therapy (higher values better). Delivered dose to rectum showed a weak correlation to “Bowel” domain (Pearson’s coefficient −0.24, p<0.001), while bladder dose did not correlate to Urinary Incontinence/Irritative/Obstructive QOL domains. Conclusion: The margin-reduced group exhibited clinically meaningful improvement of QOL without compromising the PTV dose. A larger number of patients and greater follow-up is needed to draw unequivocal conclusions. This work was supported in part by a research grant from Varian Medical Systems, Palo Alto, CA.« less

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herschtal, Alan, E-mail: Alan.Herschtal@petermac.org; Faculty of Health, Arts and Design, Swinburne University of Technology, Melbourne; Te Marvelde, Luc

    Objective: To develop a mathematical tool that can update a patient's planning target volume (PTV) partway through a course of radiation therapy to more precisely target the tumor for the remainder of treatment and reduce dose to surrounding healthy tissue. Methods and Materials: Daily on-board imaging was used to collect large datasets of displacements for patients undergoing external beam radiation therapy for solid tumors. Bayesian statistical modeling of these geometric uncertainties was used to optimally trade off between displacement data collected from previously treated patients and the progressively accumulating data from a patient currently partway through treatment, to optimally predictmore » future displacements for that patient. These predictions were used to update the PTV position and margin width for the remainder of treatment, such that the clinical target volume (CTV) was more precisely targeted. Results: Software simulation of dose to CTV and normal tissue for 2 real prostate displacement datasets consisting of 146 and 290 patients treated with a minimum of 30 fractions each showed that re-evaluating the PTV position and margin width after 8 treatment fractions reduced healthy tissue dose by 19% and 17%, respectively, while maintaining CTV dose. Conclusion: Incorporating patient-specific displacement patterns from early in a course of treatment allows PTV adaptation for the remainder of treatment. This substantially reduces the dose to healthy tissues and thus can reduce radiation therapy–induced toxicities, improving patient outcomes.« less

  17. Development of Targeted Near-Infrared Imaging Agents for Prostate Cancer

    PubMed Central

    Wang, Xinning; Huang, Steve S.; Heston, Warren D.W.; Guo, Hong; Wang, Bing-Cheng; Basilion, James P.

    2015-01-01

    Prostate cancer is the most common noncutaneous malignancy affecting men in North America. Radical prostatectomy remains a definitive treatment for prostate cancer. However, prostate surgeries are still performed “blindly” with the extent of tumor infiltration past the margins of the surgery only being determined postoperatively. An imaging modality that can be used during surgery is needed to help define the tumor margins. With its abundant expression in prostate cancer, prostate-specific membrane antigen (PSMA) is an ideal target for detection of prostate cancer. The purpose of this study was to develop PSMA-targeted near-infrared (NIR) optical imaging probes for intraoperative visualization of prostate cancer. We synthesized a high-affinity PSMA ligand (PSMA-1) with low molecular weight and further labeled it with commercially available NIR dyes IRDy800 and Cy5.5. PSMA-1 and PSMA-1–NIR conjugates had binding affinities better than the parent ligand Cys-CO-Glu. Selective binding was measured for each of the probes in both in vitro and in vivo studies using competitive binding and uptake studies. Interestingly, the results indicated that the pharmacokinetics of the probes was dependent of the fluorophore conjugated to the PSMA-1 ligand and varied widely. These data suggest that PSMA-targeted probes have the potential to be further developed as contrast agents for clinical intraoperative fluorescence-guided surgery. PMID:25239933

  18. Assessing soil quality and potential productivity - a basic approach to define and assess the marginality of land

    NASA Astrophysics Data System (ADS)

    Repmann, Frank; Gerwin, Werner; Freese, Dirk

    2017-04-01

    An ever growing demand for energy and the widely proposed switch from fossil fuels to more sustainable energy sources puts the cultivation and use of bioenergy plants into focus. However, bioenergy production on regular and fertile agricultural soils might conflict with the worldwide growing demand for food. To mitigate or omit this potential conflict, the use of low quality or marginal land for cultivation of bioenergy plants becomes favorable. Against this background the definition and assessment of land marginality and, respectively, the evaluation whether and to which extent specific areas are marginal and thus convenient for sustainable bioenergy production, becomes highly relevant. Within the framework of the EU funded Horizon 2020 project SEEMLA, we attempted to asses land marginality of designated test sites in the Ukraine, Greece and Germany by direct field survey. For that purpose, soil and site properties were investigated and evaluated by applying the Muencheberg Soil Quality Rating (SQR) method, developed at the Leibniz Centre for Agricultural Landscape Research (ZALF). The method deploys a comprehensive set of biogeophysical and chemical indicators to describe and finally evaluate the quality of the soil and site by a score ranging from 1 to 100 points. Field survey data were supported by additional laboratory tests on a representative set of soil samples. Practical field work and analysis of field and lab data from the investigated sites proved the applicability of the SQR method within the SEEMLA context. The SQR indices calculated from the field and lab data ranged from 2 to < 40 and clearly demonstrated the marginality of the investigated sites in the Ukraine, Greece and Germany, which differed considerably in respect to their characteristics. Correlating the site quality index to yield data reflecting yield estimations for common bioenergy plants such as willow (Salix sp.), black locust (Robinia pseudoacacia) and poplar (Populus sp.) cultivated at the respective test sites, revealed that SQR might additionally reflect the potential yield of the investigated sites.

  19. Light Water Reactor Sustainability Program FY13 Status Update for EPRI - RISMC Collaboration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Curtis

    2013-09-01

    The purpose of the Risk Informed Safety Margin Characterization (RISMC) Pathway research and development (R&D) is to support plant decisions for risk-informed margins management with the aim to improve economics, reliability, and sustain safety of current NPPs. Goals of the RISMC Pathway are twofold: (1) Develop and demonstrate a risk-assessment method coupled to safety margin quantification that can be used by NPP decision makers as part of their margin recovery strategies. (2) Create an advanced "RISMC toolkit" that enables more accurate representation of NPP safety margin. In order to carry out the R&D needed for the Pathway, the Idaho Nationalmore » Laboratory (INL) is collaborating with the Electric Power Research Institute (EPRI) in order to focus on applications of interest to the U.S. nuclear power industry. This report documents the collaboration activities performed between INL and EPRI during FY2013.« less

  20. Controlling marginally detached divertor plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eldon, David; Kolemen, Egemen; Barton, Joseph L.

    A new control system at DIII-D has stabilized the inter-ELM detached divertor plasma state for H-mode in close proximity to the threshold for reattachment, thus demonstrating the ability to maintain detachment with minimal gas puffing. When the same control system was instead ordered to hold the plasma at the threshold (here defined as T e = 5 eV near the divertor target plate), the resulting T e profiles separated into two groups with one group consistent with marginal detachment, and the other with marginal attachment. The plasma dithers between the attached and detached states when the control system attempts to hold at the threshold. The control system is upgraded from the one described in and it handles ELMing plasmas by using real time D α measurements to remove during-ELM slices from real time T e measurements derived from divertor Thomson scattering. The difference between measured and requested inter-ELM T e is passed to a PID (proportionalintegral-derivative) controller to determine gas puff commands. While some degree of detachment is essential for the health of ITER’s divertor, more deeply detached plasmas have greater radiative losses and, at the extreme, confinement degradation, making it desirable to limit detachment to the minimum level needed to protect the target plate. However, the observed bifurcation in plasma conditions at the outer strike point with the ion B ×more » $$\

  1. Development and evaluation of a connective tissue phantom model for subsurface visualization of cancers requiring wide local excision.

    PubMed

    Samkoe, Kimberley S; Bates, Brent D; Tselepidakis, Niki N; DSouza, Alisha V; Gunn, Jason R; Ramkumar, Dipak B; Paulsen, Keith D; Pogue, Brian W; Henderson, Eric R

    2017-12-01

    Wide local excision (WLE) of tumors with negative margins remains a challenge because surgeons cannot directly visualize the mass. Fluorescence-guided surgery (FGS) may improve surgical accuracy; however, conventional methods with direct surface tumor visualization are not immediately applicable, and properties of tissues surrounding the cancer must be considered. We developed a phantom model for sarcoma resection with the near-infrared fluorophore IRDye 800CW and used it to iteratively define the properties of connective tissues that typically surround sarcoma tumors. We then tested the ability of a blinded surgeon to resect fluorescent tumor-simulating inclusions with ∼1-cm margins using predetermined target fluorescence intensities and a Solaris open-air fluorescence imaging system. In connective tissue-simulating phantoms, fluorescence intensity decreased with increasing blood concentration and increased with increasing intralipid concentrations. Fluorescent inclusions could be resolved at ≥1-cm depth in all inclusion concentrations and sizes tested. When inclusion depth was held constant, fluorescence intensity decreased with decreasing volume. Using targeted fluorescence intensities, a blinded surgeon was able to successfully excise inclusions with ∼1-cm margins from fat- and muscle-simulating phantoms with inclusion-to-background contrast ratios as low as 2∶1. Indirect, subsurface FGS is a promising tool for surgical resection of cancers requiring WLE. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  2. Dosimetric evaluation of intrafractional tumor motion by means of a robot driven phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richter, Anne; Wilbert, Juergen; Flentje, Michael

    2011-10-15

    Purpose: The aim of the work was to investigate the influence of intrafractional tumor motion to the accumulated (absorbed) dose. The accumulated dose was determined by means of calculations and measurements with a robot driven motion phantom. Methods: Different motion scenarios and compensation techniques were realized in a phantom study to investigate the influence of motion on image acquisition, dose calculation, and dose measurement. The influence of motion on the accumulated dose was calculated by employing two methods (a model based and a voxel based method). Results: Tumor motion resulted in a blurring of steep dose gradients and a reductionmore » of dose at the periphery of the target. A systematic variation of motion parameters allowed the determination of the main influence parameters on the accumulated dose. The key parameters with the greatest influence on dose were the mean amplitude and the pattern of motion. Investigations on necessary safety margins to compensate for dose reduction have shown that smaller safety margins are sufficient, if the developed concept with optimized margins (OPT concept) was used instead of the standard internal target volume (ITV) concept. Both calculation methods were a reasonable approximation of the measured dose with the voxel based method being in better agreement with the measurements. Conclusions: Further evaluation of available systems and algorithms for dose accumulation are needed to create guidelines for the verification of the accumulated dose.« less

  3. Lower permian reef-bank bodies’ characterization in the pre-caspian basin

    NASA Astrophysics Data System (ADS)

    Wang, Zhen; Wang, Yankun; Yin, Jiquan; Luo, Man; Liang, Shuang

    2018-02-01

    Reef-bank reservoir is one of the targets for exploration of marine carbonate rocks in the Pre-Caspian Basin. Within this basin, the reef-bank bodies were primarily developed in the subsalt Devonian-Lower Permian formations, and are dominated by carbonate platform interior and margin reef-banks. The Lower Permian reef-bank present in the eastern part of the basin is considered prospective. This article provides a sequence and sedimentary facies study utilizing drilling and other data, as well as an analysis and identification of the Lower Permian reef-bank features along the eastern margin of the Pre-Caspian Basin using sub-volume coherence and seismic inversion techniques. The results indicate that the sub-volume coherence technique gives a better reflection of lateral distribution of reefs, and the seismic inversion impedance enables the identification of reef bodies’ development phases in the vertical direction, since AI (impedance) is petrophysically considered a tool for distinguishing the reef limestone and the clastic rocks within the formation (limestone exhibits a relatively high impedance than clastic rock). With this method, the existence of multiple phases of the Lower Permian reef-bank bodies along the eastern margin of the Pre-Caspian Basin has been confirmed. These reef-bank bodies are considered good subsalt exploration targets due to their lateral connectivity from south to north, large distribution range and large scale.

  4. Controlling marginally detached divertor plasmas

    DOE PAGES

    Eldon, David; Kolemen, Egemen; Barton, Joseph L.; ...

    2017-05-04

    A new control system at DIII-D has stabilized the inter-ELM detached divertor plasma state for H-mode in close proximity to the threshold for reattachment, thus demonstrating the ability to maintain detachment with minimal gas puffing. When the same control system was instead ordered to hold the plasma at the threshold (here defined as T e = 5 eV near the divertor target plate), the resulting T e profiles separated into two groups with one group consistent with marginal detachment, and the other with marginal attachment. The plasma dithers between the attached and detached states when the control system attempts to hold at the threshold. The control system is upgraded from the one described in and it handles ELMing plasmas by using real time D α measurements to remove during-ELM slices from real time T e measurements derived from divertor Thomson scattering. The difference between measured and requested inter-ELM T e is passed to a PID (proportionalintegral-derivative) controller to determine gas puff commands. While some degree of detachment is essential for the health of ITER’s divertor, more deeply detached plasmas have greater radiative losses and, at the extreme, confinement degradation, making it desirable to limit detachment to the minimum level needed to protect the target plate. However, the observed bifurcation in plasma conditions at the outer strike point with the ion B ×more » $$\

  5. Intra-surgical total and re-constructible pathological prostate examination for safer margins and nerve preservation (Istanbul preserve).

    PubMed

    Öbek, Can; Saglican, Yesim; Ince, Umit; Argun, Omer Burak; Tuna, Mustafa Bilal; Doganca, Tunkut; Tufek, Ilter; Keskin, Selcuk; Kural, Ali Riza

    2018-04-01

    To demonstrate a novel frozen section analysis technique during robot assisted radical prostatectomy with 2 distinct advantages: evaluation of the entire circumference and easier reconstruction for whole mount evaluation. Istanbul Preserve was performed on patients who underwent robotic prostatectomy with nerve sparing between 10/2014 and 7/2016. Gland was sectioned at 3-4mm intervals from apex to bladder neck. Entire tissue representing margins (except for the most anterior portion) was circumferentially excised and microscopically analyzed. In margin positivity, approach was individualized based on extent of positive margin and Gleason pattern. A matched cohort was established for comparison. Retrospective analysis of a prospectively maintained database was performed. Impact of FSA on PSM rate was primarily assessed. Data on 170 patients was analyzed. Positive surgical margin was reported in 56(33%) on frozen section. Neurovascular bundle was partially or totally resected in 79% and 18%. Conversion of positive margin to negative was achieved in 85%. Overall positive margin rate decreased from 22.5% to 7.5%. Nerve sparing increased from 87% to 93%. Location of positive margin at frozen was at the neurovascular bundle area in 39%; thus Istanbul Preserve detected 61% additional margin positivity compared to other techniques. Reconstruction for whole mount was easy. Istanbul Preserve is a novel technique for intraoperative FSA during RARP allowing for microscopic examination of the entire prostate for margin status and easy re-construction for whole mount examination. It guarantees safer margins together with increased rate of nerve sparing. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. PGE2 suppresses NK activity in vivo directly and through adrenal hormones: Effects that cannot be reflected by ex-vivo assessment of NK cytotoxicity

    PubMed Central

    Meron, G.; Tishler, Y.; Shaashua, L.; Rosenne, E.; Levi, B.; Melamed, R.; Gotlieb, N.; Matzner, P.; Sorski, L.; Ben-Eliyahu, S.

    2013-01-01

    Surgery can suppress in vivo levels of NK cell cytotoxicity (NKCC) through various mechanisms, including catecholamine-, glucocorticoid (CORT)-, and prostaglandin (PG)-mediated responses. However, PGs are synthesized locally following tissue damage, driving proinflammatory and CORT responses, while their systemic levels are often unaffected. Thus, we herein studied the role of adrenal factors in mediating in vivo effects of PGs on NKCC, using adrenalectomized and sham-operated F344 rats subjected to surgery or PGE2 administration. In vivo and ex-vivo approaches were employed, based on intravenous administration of the NK-sensitive MADB106 tumor line, and based on ex-vivo assessment of YAC-1 and MADB106 target-line lysis. Additionally, in vitro studies assessed the kinetics of the impact of epinephrine, CORT, and PGE2 on NKCC. The results indicated that suppression of NKCC by epinephrine and PGE2 are short lasting, and cannot be evident when these compounds are removed from the in vitro assay milieu, or in the context of ex-vivo assessment of NKCC. In contrast, the effects of CORT are long-lasting and are reflected in both conditions even after its removal. Marginating-pulmonary NKCC was less susceptible to suppression than circulating NKCC, when tested against the xenogeneic YAC-1 target line, but not against the syngeneic MADB106 line, which seems to involve different cytotoxicity mechanisms. Overall, these findings indicate that elevated systemic PG levels can directly suppress NKCC in vivo, but following laparotomy adrenal hormones mediate most of the effects of endogenously-released PGs. Additionally, the ex-vivo approach seems limited in reflecting the short-lasting NK-suppressive effects of catecholamines and PGs. PMID:23153554

  7. PGE2 suppresses NK activity in vivo directly and through adrenal hormones: effects that cannot be reflected by ex vivo assessment of NK cytotoxicity.

    PubMed

    Meron, G; Tishler, Y; Shaashua, L; Rosenne, E; Levi, B; Melamed, R; Gotlieb, N; Matzner, P; Sorski, L; Ben-Eliyahu, S

    2013-02-01

    Surgery can suppress in vivo levels of NK cell cytotoxicity (NKCC) through various mechanisms, including catecholamine-, glucocorticoid (CORT)-, and prostaglandin (PG)-mediated responses. However, PGs are synthesized locally following tissue damage, driving proinflammatory and CORT responses, while their systemic levels are often unaffected. Thus, we herein studied the role of adrenal factors in mediating in vivo effects of PGs on NKCC, using adrenalectomized and sham-operated F344 rats subjected to surgery or PGE(2) administration. In vivo and ex vivo approaches were employed, based on intravenous administration of the NK-sensitive MADB106 tumor line, and based on ex vivo assessment of YAC-1 and MADB106 target-line lysis. Additionally, in vitro studies assessed the kinetics of the impact of epinephrine, CORT, and PGE(2) on NKCC. The results indicated that suppression of NKCC by epinephrine and PGE(2) are short lasting, and cannot be evident when these compounds are removed from the in vitro assay milieu, or in the context of ex vivo assessment of NKCC. In contrast, the effects of CORT are long-lasting and are reflected in both conditions even after its removal. Marginating-pulmonary NKCC was less susceptible to suppression than circulating NKCC, when tested against the xenogeneic YAC-1 target line, but not against the syngeneic MADB106 line, which seems to involve different cytotoxicity mechanisms. Overall, these findings indicate that elevated systemic PG levels can directly suppress NKCC in vivo, but following laparotomy adrenal hormones mediate most of the effects of endogenously-released PGs. Additionally, the ex vivo approach seems limited in reflecting the short-lasting NK-suppressive effects of catecholamines and PGs. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Development of future indications for BOTOX.

    PubMed

    Brin, Mitchell F

    2009-10-01

    Since the late 1970s, local injections of BoNT have provided clinical benefit for patients with inappropriately contracting muscles with or without pain or sensory disturbance. Marketing authorization for some BoNTs, depending on country, include core indications of dystonia (blepharospasm and cervical dystonia), large muscle spastic disorders (not yet approved in the United States, e.g., adult post-stroke spasticity and equinus foot deformity), hyperhidrosis and aesthetic. Subsequent development has extended to selected conditions characterized by recurrent or chronic pain (migraine headache), and urologic indications (neurogenic/idiopathic overactive bladder; prostate hyperplasia), with multiple additional opportunities available. Portfolio management requires a careful individual opportunity assessment of scientific and technical aspects (basic science foundation, potential to treat unmet medical need, product-specific risk in specific populations, therapeutic margin/safety profile, and probability of successful registration pathway). This article describes ongoing development targets for BOTOX.

  9. Preclinical evaluation of nuclear morphometry and tissue topology for breast carcinoma detection and margin assessment

    PubMed Central

    Nyirenda, Ndeke; Farkas, Daniel L.

    2010-01-01

    Prevention and early detection of breast cancer are the major prophylactic measures taken to reduce the breast cancer related mortality and morbidity. Clinical management of breast cancer largely relies on the efficacy of the breast-conserving surgeries and the subsequent radiation therapy. A key problem that limits the success of these surgeries is the lack of accurate, real-time knowledge about the positive tumor margins in the surgically excised tumors in the operating room. This leads to tumor recurrence and, hence, the need for repeated surgeries. Current intraoperative techniques such as frozen section pathology or touch imprint cytology severely suffer from poor sampling and non-optimal detection sensitivity. Even though histopathology analysis can provide information on positive tumor margins post-operatively (~2–3 days), this information is of no immediate utility in the operating rooms. In this article, we propose a novel image analysis method for tumor margin assessment based on nuclear morphometry and tissue topology and demonstrate its high sensitivity/specificity in preclinical animal model of breast carcinoma. The method relies on imaging nuclear-specific fluorescence in the excised surgical specimen and on extracting nuclear morphometric parameters (size, number, and area fraction) from the spatial distribution of the observed fluorescence in the tissue. We also report the utility of tissue topology in tumor margin assessment by measuring the fractal dimension in the same set of images. By a systematic analysis of multiple breast tissues specimens, we show here that the proposed method is not only accurate (~97% sensitivity and 96% specificity) in thin sections, but also in three-dimensional (3D) thick tissues that mimic the realistic lumpectomy specimens. Our data clearly precludes the utility of nuclear size as a reliable diagnostic criterion for tumor margin assessment. On the other hand, nuclear area fraction addresses this issue very effectively since it is a combination of both nuclear size and count in any given region of the analyzed image, and thus yields high sensitivity and specificity (~97%) in tumor detection. This is further substantiated by an independent parameter, fractal dimension, based on the tissue topology. Although the basic definition of cancer as an uncontrolled cell growth entails a high nuclear density in tumor regions, a simple but systematic exploration of nuclear distribution in thick tissues by nuclear morphometry and tissue topology as performed in this study has never been carried out, to the best of our knowledge. We discuss the practical aspects of implementing this imaging approach in automated tissue sampling scenario where the accuracy of tumor margin assessment can be significantly increased by scanning the entire surgical specimen rather than sampling only a few sections as in current histopathology analysis. PMID:20446030

  10. Three-dimensional and topographic relationships between the orbital margins with reference to assessment of eyeball protrusion

    PubMed Central

    Shin, Kang-Jae; Lee, Shin-Hyo; Koh, Ki-Seok

    2017-01-01

    This study investigated the topographic relationships among the eyeball and four orbital margins with the aim of identifying the correlation between orbital geometry and eyeball protrusion in Koreans. Three-dimensional (3D) volume rendering of the face was performed using serial computed-tomography images of 141 Koreans, and several landmarks on the bony orbit and the cornea were directly marked on the 3D volumes. The anterior-posterior distances from the apex of the cornea to each orbital margin and between the orbital margins were measured in both eyes. The distances from the apex of the cornea to the superior, medial, inferior, and lateral orbital margins were 5.8, 5.8, 12.0, and 17.9 mm, respectively. Differences between sides were observed in all of the orbital margins, and the distances from the apex of the cornea to the superior and inferior orbital margins were significantly greater in females than in males. The anterior-posterior distance between the superior and inferior orbital margins did not differ significantly between males (6.3 mm) and females (6.2 mm). The data obtained in this study will be useful when developing practical guidelines applicable to forensic facial reconstruction and orbitofacial surgeries. PMID:28417054

  11. Patterns of care and outcomes of adjuvant therapy for high-risk head and neck cancer after surgery.

    PubMed

    Osborn, Virginia Wedell; Givi, Babak; Rineer, Justin; Roden, Dylan; Sheth, Niki; Lederman, Ariel; Katsoulakis, Evangelia; Hu, Kenneth; Schreiber, David

    2018-06-01

    Postoperative chemoradiotherapy (CRT) is considered standard of care in patients with locally advanced head and neck cancer with positive margins and/or extracapsular extension (ECE). The National Cancer Data Base (NCDB) was queried to identify patients with squamous cell carcinoma of the head and neck with stages III to IVB disease or with positive margins and/or ECE diagnosed between 2004 and 2012 receiving postoperative radiotherapy (RT). Using univariable and multivariable logistic and Cox regression, we assessed for predictors of CRT use and covariables impacting overall survival (OS), including in a propensity-matched subset. Of 12 224 patients, 67.1% with positive margins and/or ECE received CRT as well as 54.0% without positive margins and/or ECE. The 5-year OS was 61.6% for RT alone versus 67.4% for CRT. In the propensity-matched cohort, OS benefit persisted with CRT, including in a subset with positive margins and/or ECE but not without. Postoperative CRT seems underutilized with positive margins and/or ECE and overutilized without positive margins and/or ECE. The CRT was associated with improved OS but the benefit persisted only in the subset with positive margins and/or ECE. © 2018 Wiley Periodicals, Inc.

  12. Margin reduction from image guided radiation therapy for soft tissue sarcoma: Secondary analysis of Radiation Therapy Oncology Group 0630 results.

    PubMed

    Li, X Allen; Chen, Xiaojian; Zhang, Qiang; Kirsch, David G; Petersen, Ivy; DeLaney, Thomas F; Freeman, Carolyn R; Trotti, Andy; Hitchcock, Ying; Bedi, Meena; Haddock, Michael; Salerno, Kilian; Dundas, George; Wang, Dian

    2016-01-01

    Six imaging modalities were used in Radiation Therapy Oncology Group (RTOG) 0630, a study of image guided radiation therapy (IGRT) for primary soft tissue sarcomas of the extremity. We analyzed all daily patient-repositioning data collected in this trial to determine the impact of daily IGRT on clinical target volume-to-planning target volume (CTV-to-PTV) margin. Daily repositioning data, including shifts in right-left (RL), superior-inferior (SI), and anterior-posterior (AP) directions and rotations for 98 patients enrolled in RTOG 0630 from 18 institutions were analyzed. Patients were repositioned daily on the basis of bone anatomy by using pretreatment images, including kilovoltage orthogonal images (KVorth), megavoltage orthogonal images (MVorth), KV fan-beam computed tomography (KVCT), KV cone beam CT (KVCB), MV fan-beam CT (MVCT), and MV cone beam CT (MVCB). Means and standard deviations (SDs) for each shift and rotation were calculated for each patient and for each IGRT modality. The Student's t tests and F-tests were performed to analyze the differences in the means and SDs. Necessary CTV-to-PTV margins were estimated. The repositioning shifts and day-to-day variations were large and generally similar for the 6 imaging modalities. Of the 2 most commonly used modalities, MVCT and KVorth, there were no statistically significant differences in the shifts and rotations (P = .15 and .59 for the RL and SI shifts, respectively; and P = .22 for rotation), except for shifts in AP direction (P = .002). The estimated CTV-to-PTV margins in the RL, SI, and AP directions would be 13.0, 10.4, and 11.7 mm from MVCT data, respectively, and 13.1, 8.6, and 10.8 mm from KVorth data, respectively, indicating that margins substantially larger than 5 mm used with daily IGRT would be required in the absence of IGRT. The observed large daily repositioning errors and the large variations among institutions imply that daily IGRT is necessary for this tumor site, particularly in multi-institutional trials. Otherwise, a CTV-to-PTV margin of 1.5 cm is required to account for daily setup variations. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  13. Technical Note: A treatment plan comparison between dynamic collimation and a fixed aperture during spot scanning proton therapy for brain treatment

    PubMed Central

    Smith, Blake; Gelover, Edgar; Moignier, Alexandra; Wang, Dongxu; Flynn, Ryan T.; Lin, Liyong; Kirk, Maura; Solberg, Tim; Hyer, Daniel E.

    2016-01-01

    Purpose: To quantitatively assess the advantages of energy-layer specific dynamic collimation system (DCS) versus a per-field fixed aperture for spot scanning proton therapy (SSPT). Methods: Five brain cancer patients previously planned and treated with SSPT were replanned using an in-house treatment planning system capable of modeling collimated and uncollimated proton beamlets. The uncollimated plans, which served as a baseline for comparison, reproduced the target coverage and organ-at-risk sparing of the clinically delivered plans. The collimator opening for the fixed aperture-based plans was determined from the combined cross sections of the target in the beam’s eye view over all energy layers which included an additional margin equivalent to the maximum beamlet displacement for the respective energy of that energy layer. The DCS-based plans were created by selecting appropriate collimator positions for each row of beam spots during a Raster-style scanning pattern which were optimized to maximize the dose contributions to the target and limited the dose delivered to adjacent normal tissue. Results: The reduction of mean dose to normal tissue adjacent to the target, as defined by a 10 mm ring surrounding the target, averaged 13.65% (range: 11.8%–16.9%) and 5.18% (2.9%–7.1%) for the DCS and fixed aperture plans, respectively. The conformity index, as defined by the ratio of the volume of the 50% isodose line to the target volume, yielded an average improvement of 21.35% (19.4%–22.6%) and 8.38% (4.7%–12.0%) for the DCS and fixed aperture plans, respectively. Conclusions: The ability of the DCS to provide collimation to each energy layer yielded better conformity in comparison to fixed aperture plans. PMID:27487886

  14. PAX5 methylation detection by droplet digital PCR for ultra-sensitive deep surgical margins analysis of head and neck squamous cell carcinoma

    PubMed Central

    Hayashi, Masamichi; Guerrero-Preston, Rafael; Sidransky, David; Koch, Wayne M.

    2015-01-01

    Molecular deep surgical margin analysis has been shown to predict locoregional recurrences of head and neck squamous cell carcinoma (HNSCC). In order to improve the accuracy and versatility of the analysis, we used a highly tumor-specific methylation marker and highly sensitive detection technology to test DNA from surgical margins. Histologically cancer-negative deep surgical margin samples were prospectively collected from 82 eligible HNSCC surgeries by an imprinting procedure (n=75) and primary tissue collection (n=70). Bisulfite treated DNA from each sample was analyzed by both conventional quantitative methylation-specific polymerase chain reaction (QMSP) and QMSP by droplet digital PCR (ddQMSP) targeting PAX5 gene promoter methylation. The association between the presence of PAX5 methylation and locoregional recurrence free survival (LRFS) was evaluated. PAX5 methylation was found in 68.0% (51/75) of tumors in the imprint samples and 71.4% (50/70) in the primary tissue samples. Among cases which did not have postoperative radiation, (n=31 in imprint samples, n=29 in tissue samples), both conventional QMSP and ddQMSP revealed that PAX5 methylation positive margins was significantly associated with poor LRFS by univariate analysis. In particular, ddQMSP increased detection of the PAX5 marker from 29% to 71% in the non-radiated imprint cases. Also, PAX5 methylated imprint margins were an excellent predictor of poor LRFS (HR=3.89, 95%CI:1.19-17.52, P=0.023) by multivariate analysis. PAX5 methylation appears to be an excellent tumor-specific marker for molecular deep surgical margin analysis of HNSCC. Moreover, the ddQMSP assay displays increased sensitivity for methylation marker detection. PMID:26304463

  15. Re-Engaging Marginalized Youth through Digital Music Production: Performance, Audience and Evaluation

    ERIC Educational Resources Information Center

    Brader, Andy; Luke, Allan

    2013-01-01

    This article presents two case studies of marginalized youth experimenting with digital music production in flexible education settings. The cases were drawn from a 3-year study of alternative assessment in flexible learning centres for youth who have left formal schooling in Queensland, Australia. The educational issues are framed by reference to…

  16. Pathology report assessment of incidental gallbladder carcinoma diagnosed from cholecystectomy specimens: results of a French multicentre survey.

    PubMed

    Chatelain, Denis; Fuks, David; Farges, Olivier; Attencourt, Christophe; Pruvot, François René; Regimbeau, Jean-Marc

    2013-12-01

    To assess the accuracy of pathology reports on gallbladder specimens from patients operated on for incidental gallbladder carcinoma. Demographic data, details on pathological reports including gross and microscopic features section were recorded in 100 selected patients with incidental gallbladder carcinoma diagnosed from 2004 to 2007. Pathology reports had a conventional format in 93% of cases, without any standardization. Turnaround time ranged from 1 to 35 days. Frozen sections were performed in 20% of cases. The reports failed to give information on prognostic histological factors: exact tumour site (missing in 55% of cases), depth of tumour infiltration within the gallbladder wall (missing in 10%), surgical margins (missing in 40% for the cystic duct margin), tumour differentiation (missing in 28%), vascular invasion (missing in 52%) and perineural invasion (missing in 51%). Lymph node status could be assessed in 44% of cases. Distances between the tumour and the cystic duct and circumferential margins were not specified in 68% and 84% of cases. Only 29% of the reports clearly stated the pTNM stage in the conclusion section. The pT stage with margin status and tumour site was only mentioned in 30% of the reports. Pathology reports on gallbladder carcinoma from participating centres frequently lacked important information on key prognostic histological factors. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  17. Pharmacokinetic drivers of toxicity for basic molecules: Strategy to lower pKa results in decreased tissue exposure and toxicity for a small molecule Met inhibitor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Diaz, Dolores, E-mail: diaz.dolores@gene.com; Ford, Kevin A.; Hartley, Dylan P.

    Several toxicities are clearly driven by free drug concentrations in plasma, such as toxicities related to on-target exaggerated pharmacology or off-target pharmacological activity associated with receptors, enzymes or ion channels. However, there are examples in which organ toxicities appear to correlate better with total drug concentrations in the target tissues, rather than with free drug concentrations in plasma. Here we present a case study in which a small molecule Met inhibitor, GEN-203, with significant liver and bone marrow toxicity in preclinical species was modified with the intention of increasing the safety margin. GEN-203 is a lipophilic weak base as demonstratedmore » by its physicochemical and structural properties: high LogD (distribution coefficient) (4.3) and high measured pKa (7.45) due to the basic amine (N-ethyl-3-fluoro-4-aminopiperidine). The physicochemical properties of GEN-203 were hypothesized to drive the high distribution of this compound to tissues as evidenced by a moderately-high volume of distribution (Vd > 3 l/kg) in mouse and subsequent toxicities of the compound. Specifically, the basicity of GEN-203 was decreased through addition of a second fluorine in the 3-position of the aminopiperidine to yield GEN-890 (N-ethyl-3,3-difluoro-4-aminopiperidine), which decreased the volume of distribution of the compound in mouse (Vd = 1.0 l/kg), decreased its tissue drug concentrations and led to decreased toxicity in mice. This strategy suggests that when toxicity is driven by tissue drug concentrations, optimization of the physicochemical parameters that drive tissue distribution can result in decreased drug concentrations in tissues, resulting in lower toxicity and improved safety margins. -- Highlights: ► Lower pKa for a small molecule: reduced tissue drug levels and toxicity. ► New analysis tools to assess electrostatic effects and ionization are presented. ► Chemical and PK drivers of toxicity can be leveraged to improve safety.« less

  18. Excision margins and sentinel lymph node status as prognostic factors in thick melanoma of the head and neck: A retrospective analysis.

    PubMed

    Ruskin, Olivia; Sanelli, Alexandra; Herschtal, Alan; Webb, Angela; Dixon, Ben; Pohl, Miklos; Donahoe, Simon; Spillane, John; Henderson, Michael A; Gyorki, David E

    2016-09-01

    Recommended margins for thick cutaneous melanoma (Breslow thickness >4 mm; T4) have decreased over recent decades. Optimal margins and the role of sentinel node biopsy (SNB) in thick head and neck melanoma remain controversial. A single-center review was conducted of patients treated between 2002 and 2012 assessing the impact of excision margins and sentinel lymph node status on locoregional recurrence and melanoma-specific survival (MSS). One hundred eight patients were identified. Median age was 71.1 years and median Breslow thickness was 6.0 mm. Median follow-up was 40 months. Locoregional recurrence occurred in 27% and there was no significant reduction in recurrence with margins ≥2 cm (p = .17). Increasing margins did not improve survival (p = .58). Fifty-nine patients (55%) underwent SNB, of which 27% were positive. There was a trend toward longer survival for patients who were sentinel lymph node-negative (p = .097). Wider margins do not significantly improve locoregional recurrence or MSS. Sentinel lymph node involvement reflects a poor prognosis. © 2016 Wiley Periodicals, Inc. Head Neck 38: 1373-1379, 2016. © 2016 Wiley Periodicals, Inc.

  19. Towards intraoperative surgical margin assessment and visualization using bioimpedance properties of the tissue

    NASA Astrophysics Data System (ADS)

    Khan, Shadab; Mahara, Aditya; Hyams, Elias S.; Schned, Alan; Halter, Ryan

    2015-03-01

    Prostate cancer (PCa) has a high 10-year recurrence rate, making PCa the second leading cause of cancer-specific mortality among men in the USA. PCa recurrences are often predicted by assessing the status of surgical margins (SM) with positive surgical margins (PSM) increasing the chances of biochemical recurrence by 2-4 times. To this end, an SM assessment system using Electrical Impedance Spectroscopy (EIS) was developed with a microendoscopic probe. This system measures the tissue bioimpedance over a range of frequencies (1 kHz to 1MHz), and computes a Composite Impedance Metric (CIM). CIM can be used to classify tissue as benign or cancerous. The system was used to collect the impedance spectra from excised prostates, which were obtained from men undergoing radical prostatectomy. The data revealed statistically significant (p<0.05) differences in the impedance properties of the benign and tumorous tissues, and between different tissue morphologies. To visualize the results of SM-assessment, a visualization tool using da Vinci stereo laparoscope is being developed. Together with the visualization tool, the EIS-based SM assessment system can be potentially used to intraoperatively classify tissues and display the results on the surgical console with a video feed of the surgical site, thereby augmenting a surgeon's view of the site and providing a potential solution to the intraoperative SM assessment needs.

  20. Improved setup and positioning accuracy using a three‐point customized cushion/mask/bite‐block immobilization system for stereotactic reirradiation of head and neck cancer

    PubMed Central

    Wang, He; Wang, Congjun; Tung, Samuel; Dimmitt, Andrew Wilson; Wong, Pei Fong; Edson, Mark A.; Garden, Adam S.; Rosenthal, David I.; Fuller, Clifton D.; Gunn, Gary B.; Takiar, Vinita; Wang, Xin A.; Luo, Dershan; Yang, James N.; Wong, Jennifer

    2016-01-01

    The purpose of this study was to investigate the setup and positioning uncertainty of a custom cushion/mask/bite‐block (CMB) immobilization system and determine PTV margin for image‐guided head and neck stereotactic ablative radiotherapy (HN‐SABR). We analyzed 105 treatment sessions among 21 patients treated with HN‐SABR for recurrent head and neck cancers using a custom CMB immobilization system. Initial patient setup was performed using the ExacTrac infrared (IR) tracking system and initial setup errors were based on comparison of ExacTrac IR tracking system to corrected online ExacTrac X‐rays images registered to treatment plans. Residual setup errors were determined using repeat verification X‐ray. The online ExacTrac corrections were compared to cone‐beam CT (CBCT) before treatment to assess agreement. Intrafractional positioning errors were determined using prebeam X‐rays. The systematic and random errors were analyzed. The initial translational setup errors were −0.8±1.3 mm, −0.8±1.6 mm, and 0.3±1.9 mm in AP, CC, and LR directions, respectively, with a three‐dimensional (3D) vector of 2.7±1.4 mm. The initial rotational errors were up to 2.4° if 6D couch is not available. CBCT agreed with ExacTrac X‐ray images to within 2 mm and 2.5°. The intrafractional uncertainties were 0.1±0.6 mm, 0.1±0.6 mm, and 0.2±0.5 mm in AP, CC, and LR directions, respectively, and 0.0∘±0.5°, 0.0∘±0.6°, and −0.1∘±0.4∘ in yaw, roll, and pitch direction, respectively. The translational vector was 0.9±0.6 mm. The calculated PTV margins mPTV(90,95) were within 1.6 mm when using image guidance for online setup correction. The use of image guidance for online setup correction, in combination with our customized CMB device, highly restricted target motion during treatments and provided robust immobilization to ensure minimum dose of 95% to target volume with 2.0 mm PTV margin for HN‐SABR. PACS number(s): 87.55.ne PMID:27167275

  1. Neurovascular bundle–sparing radiotherapy for prostate cancer using MRI-CT registration: A dosimetric feasibility study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cassidy, R.J., E-mail: richardjcassidy@emory.edu; Yang, X.; Liu, T.

    Purpose: Sexual dysfunction after radiotherapy for prostate cancer remains an important late adverse toxicity. The neurovascular bundles (NVB) that lie posterolaterally to the prostate are typically spared during prostatectomy, but in traditional radiotherapy planning they are not contoured as an organ-at-risk with dose constraints. Our goal was to determine the dosimetric feasibility of “NVB-sparing” prostate radiotherapy while still delivering adequate dose to the prostate. Methods: Twenty-five consecutive patients with prostate cancer (with no extraprostatic disease on pelvic magnetic resonance imaging [MRI]) who that were treated with external beam radiotherapy, with the same primary planning target volume margins, to a dosemore » of 79.2 Gy were evaluated. Pelvic MRI and simulation computed tomography scans were registered using dedicated software to allow for bilateral NVB target delineation on T2-weighted MRI. A volumetric modulated arc therapy plan was generated using the NVB bilaterally with 2 mm margin as an organ to spare and compared to the patient’s previously delivered plan. Dose-volume histogram endpoints for NVB, rectum, bladder, and planning target volume 79.2 were compared between the 2 plans using a 2-tailed paired t-test. Results: The V70 for the NVB was significantly lower on the NVB-sparing plan (p <0.01), while rectum and bladder endpoints were similar. Target V100% was similar but V{sub 105%} was higher for the NVB-sparing plans (p <0.01). Conclusions: “NVB-sparing” radiotherapy is dosimetrically feasible using CT-MRI registration, and for volumetric modulated arc therapy technology — target coverage is acceptable without increased dose to other normal structures, but with higher target dose inhomogeneity. The clinical impact of “NVB-sparing” radiotherapy is currently under study at our institution.« less

  2. Potential for Woody Bioenergy Crops Grown on Marginal Lands in the US Midwest to Reduce Carbon Emissions

    NASA Astrophysics Data System (ADS)

    Sahajpal, R.; Hurtt, G. C.; Fisk, J. P.; Izaurralde, R. C.; Zhang, X.

    2012-12-01

    While cellulosic biofuels are widely considered to be a low carbon energy source for the future, a comprehensive assessment of the environmental sustainability of existing and future biofuel systems is needed to assess their utility in meeting US energy and food needs without exacerbating environmental harm. To assess the carbon emission reduction potential of cellulosic biofuels, we need to identify lands that are initially not storing large quantities of carbon in soil and vegetation but are capable of producing abundant biomass with limited management inputs, and accurately model forest production rates and associated input requirements. Here we present modeled results for carbon emission reduction potential and cellulosic ethanol production of woody bioenergy crops replacing existing native prairie vegetation grown on marginal lands in the US Midwest. Marginal lands are selected based on soil properties describing use limitation, and are extracted from the SSURGO (Soil Survey Geographic) database. Yield estimates for existing native prairie vegetation on marginal lands modeled using the process-based field-scale model EPIC (Environmental Policy Integrated Climate) amount to ~ 6.7±2.0 Mg ha-1. To model woody bioenergy crops, the individual-based terrestrial ecosystem model ED (Ecosystem Demography) is initialized with the soil organic carbon stocks estimated at the end of the EPIC simulation. Four woody bioenergy crops: willow, southern pine, eucalyptus and poplar are parameterized in ED. Sensitivity analysis of model parameters and drivers is conducted to explore the range of carbon emission reduction possible with variation in woody bioenergy crop types, spatial and temporal resolution. We hypothesize that growing cellulosic crops on these marginal lands can provide significant water quality, biodiversity and GHG emissions mitigation benefits, without accruing additional carbon costs from the displacement of food and feed production.

  3. Effect of land use change for bioenergy on greenhouse gas emissions from a wet marginal soil in New York State, USA.

    NASA Astrophysics Data System (ADS)

    Stoof, Cathelijne; Mason, Cedric; Steenhuis, Tammo; Richards, Brian

    2013-04-01

    Millions of hectares of marginal lands in the Northeast USA no longer used for agriculture are suitable for production of second-generation cellulosic bioenergy crops, offering the potential for regional bioenergy production without inducing food vs. fuel competition for prime farmland. Abundant water resources, close proximity between production and markets, and compatibility with existing agricultural systems all favor development in the region. Yet, little is known about how sustainable bioenergy crop production on marginal lands is regarding greenhouse gas emissions. In a 10-ha field trial on wet marginal soils in upstate New York, we are assessing the effect of land use change (from fallow land to perennial grass stands) on N2O and CH4 emissions. The deep clay loam is unsuited for row-crop agriculture because it is too dry in summer and too wet in winter. Monthly chamber campaigns were performed from April to November 2012 to monitor large scale (10-20 m resolution) differences caused by land cover type (n=4 for both switchgrass, reed-canary grass and a 50-yr unplowed control) across soil moisture gradients (n=5 soil moisture levels per replicate). Additional weekly campaigns assessed the smaller scale spatial and temporal variability in emissions at meter-scale. Here we present results of both the large and small-scale patterns in greenhouse gas emissions from this marginal soil, and discuss effects of soil properties and hydrologic conditions as potential drivers. Insight gained about the environmental impact of bioenergy crops can be used to assess the sustainability of using this region's underutilized land base for energy production.

  4. Paleogeographic constraints on continental-scale source-to-sink systems: Northern South America and its Atlantic margins

    NASA Astrophysics Data System (ADS)

    Bajolet, Flora; Chardon, Dominique; Rouby, Delphine; Dall'Asta, Massimo; Roig, Jean-Yves; Loparev, Artiom; Coueffe, Renaud

    2017-04-01

    Our work aims at setting the evolving boundary conditions of erosion and sediments transfer, transit, and onshore-offshore accumulations on northern South America and along its Atlantic margins. Since the Early Mesozoic, the source-to-sink system evolved under the interplay of four main processes, which are (i) volcanism and arc building along the proto-Andes, (ii) long-term dynamics of the Amazon incratonic basin, (iii) rifting, relaxation and rejuvenation of the Atlantic margins and (iv) building of the Andes. We compiled information available from geological maps and the literature regarding tectonics, plate kinematics, magmatism, stratigraphy, sedimentology (including paleoenvironments and currents) and thermochronology to produce a series of paleogeographic maps showing the tectonic and kinematic framework of continental areas under erosion (sources), by-pass and accumulation (sinks) over the Amazonian craton, its adjacent regions and along its Atlantic margins. The maps also allow assessing the relative impact of (i) ongoing Pacific subduction, (ii) Atlantic rifting and its aftermath, and (iii) Atlantic slab retreat from under the Caribbean domain on the distribution and activity of onshore/offshore sedimentary basins. Stratigraphic and thermochronology data are also used to assess denudation / vertical motions due to sediment transfers and lithosphere-asthenosphere interactions. This study ultimately aims at linking the sediment routing system to long-wavelength deformation of northern South America under the influence of mountain building, intracratonic geodynamics, divergent margin systems and mantle dynamics.

  5. Effect of various putty-wash impression techniques on marginal fit of cast crowns.

    PubMed

    Nissan, Joseph; Rosner, Ofir; Bukhari, Mohammed Amin; Ghelfan, Oded; Pilo, Raphael

    2013-01-01

    Marginal fit is an important clinical factor that affects restoration longevity. The accuracy of three polyvinyl siloxane putty-wash impression techniques was compared by marginal fit assessment using the nondestructive method. A stainless steel master cast containing three abutments with three metal crowns matching the three preparations was used to make 45 impressions: group A = single-step technique (putty and wash impression materials used simultaneously), group B = two-step technique with a 2-mm relief (putty as a preliminary impression to create a 2-mm wash space followed by the wash stage), and group C = two-step technique with a polyethylene spacer (plastic spacer used with the putty impression followed by the wash stage). Accuracy was assessed using a toolmaker microscope to measure and compare the marginal gaps between each crown and finish line on the duplicated stone casts. Each abutment was further measured at the mesial, buccal, and distal aspects. One-way analysis of variance was used for statistical analysis. P values and Scheffe post hoc contrasts were calculated. Significance was determined at .05. One-way analysis of variance showed significant differences among the three impression techniques in all three abutments and at all three locations (P < .001). Group B yielded dies with minimal gaps compared to groups A and C. The two-step impression technique with 2-mm relief was the most accurate regarding the crucial clinical factor of marginal fit.

  6. Wide-field optical coherence elastography for intraoperative assessment of tumour margins in breast cancer (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Allen, Wes M.; Chin, Lixin; Sampson, David D.; Kennedy, Brendan F.

    2016-03-01

    Incomplete excision of tumour margins is a major issue in breast-conserving surgery. Currently 20 - 60% of cases require a second surgical procedure required as a result of cancer recurrence. A number of techniques have been proposed to assess margin status, including frozen section analysis and imprint cytology. However, the recurrence rate after using these techniques remains very high. Over the last several years, our group has been developing optical coherence elastography (OCE) as a tool for the intraoperative assessment of tumour margins in breast cancer. We have reported a feasibility study on 65 ex vivo samples from patients undergoing mastectomy or wide local excision demonstrates the potential of OCE in differentiating benign from malignant tissue. In this study, malignant tissue was readily distinguished from surrounding relative tissue by a distinctive heterogeneous pattern in micro-elastograms. To date the largest field of view for a micro-elastogram is 20 x 20mm, however, lumpectomy samples are typically ~50 x 50 x 30mm. For OCE to progress as a useful clinical tool, elastograms must be acquired over larger areas to allow a greater portion of the surface area of lumpectomies to be assessed. Here, we propose a wide-field OCE scanner that utilizes a piezoelectric transducer with an internal diameter of 65mm. In this approach partially overlapped elastograms are stitched together forming a mosaic with overall dimensions of 50 x 50mm in a total acquisition time of 15 - 30 minutes. We present results using this approach on both tissue-mimicking phantoms and tissue, and discuss prospects for shorter acquisitions times.

  7. Early Oral Tongue Squamous Cell Carcinoma: Sampling of Margins From Tumor Bed and Worse Local Control.

    PubMed

    Maxwell, Jessica H; Thompson, Lester D R; Brandwein-Gensler, Margaret S; Weiss, Bernhard G; Canis, Martin; Purgina, Bibianna; Prabhu, Arpan V; Lai, Chi; Shuai, Yongli; Carroll, William R; Morlandt, Anthony; Duvvuri, Umamaheswar; Kim, Seungwon; Johnson, Jonas T; Ferris, Robert L; Seethala, Raja; Chiosea, Simion I

    2015-12-01

    Positive margins are associated with poor prognosis among patients with oral tongue squamous cell carcinoma (SCC). However, wide variation exists in the margin sampling technique. To determine the effect of the margin sampling technique on local recurrence (LR) in patients with stage I or II oral tongue SCC. A retrospective study was conducted from January 1, 1986, to December 31, 2012, in 5 tertiary care centers following tumor resection and elective neck dissection in 280 patients with pathologic (p)T1-2 pN0 oral tongue SCC. Analysis was conducted from June 1, 2013, to January 20, 2015. In group 1 (n = 119), tumor bed margins were not sampled. In group 2 (n = 61), margins were examined from the glossectomy specimen, found to be positive or suboptimal, and revised with additional tumor bed margins. In group 3 (n = 100), margins were primarily sampled from the tumor bed without preceding examination of the glossectomy specimen. The margin status (both as a binary [positive vs negative] and continuous [distance to the margin in millimeters] variable) and other clinicopathologic parameters were compared across the 3 groups and correlated with LR. Local recurrence. Age, sex, pT stage, lymphovascular or perineural invasion, and adjuvant radiation treatment were similar across the 3 groups. The probability of LR-free survival at 3 years was 0.9 and 0.8 in groups 1 and 3, respectively (P = .03). The frequency of positive glossectomy margins was lowest in group 1 (9 of 117 [7.7%]) compared with groups 2 and 3 (28 of 61 [45.9%] and 23 of 95 [24.2%], respectively) (P < .001). Even after excluding cases with positive margins, the median distance to the closest margin was significantly narrower in group 3 (2 mm) compared with group 1 (3 mm) (P = .008). The status (positive vs negative) of margins obtained from the glossectomy specimen correlated with LR (P = .007), while the status of tumor bed margins did not. The status of the tumor bed margin was 24% sensitive (95% CI, 16%-34%) and 92% specific (95% CI, 85%-97%) for detecting a positive glossectomy margin. The margin sampling technique affects local control in patients with oral tongue SCC. Reliance on margin sampling from the tumor bed is associated with worse local control, most likely owing to narrower margin clearance and greater incidence of positive margins. A resection specimen-based margin assessment is recommended.

  8. Early Oral Tongue Squamous Cell Carcinoma Sampling of Margins From Tumor Bed and Worse Local Control

    PubMed Central

    Maxwell, Jessica H.; Thompson, Lester D. R.; Brandwein-Gensler, Margaret S.; Weiss, Bernhard G.; Canis, Martin; Purgina, Bibianna; Prabhu, Arpan V.; Lai, Chi; Shuai, Yongli; Carroll, William R.; Morlandt, Anthony; Duvvuri, Umamaheswar; Kim, Seungwon; Johnson, Jonas T.; Ferris, Robert L.; Seethala, Raja; Chiosea, Simion I.

    2017-01-01

    IMPORTANCE Positive margins are associated with poor prognosis among patients with oral tongue squamous cell carcinoma (SCC). However, wide variation exists in the margin sampling technique. OBJECTIVE To determine the effect of the margin sampling technique on local recurrence (LR) in patients with stage I or II oral tongue SCC. DESIGN, SETTING, AND PARTICIPANTS A retrospective study was conducted from January 1, 1986, to December 31, 2012, in 5 tertiary care centers following tumor resection and elective neck dissection in 280 patients with pathologic (p)T1-2 pN0 oral tongue SCC. Analysis was conducted from June 1, 2013, to January 20, 2015. INTERVENTIONS In group 1 (n = 119), tumor bed margins were not sampled. In group 2 (n = 61), margins were examined from the glossectomy specimen, found to be positive or suboptimal, and revised with additional tumor bed margins. In group 3 (n = 100), margins were primarily sampled from the tumor bed without preceding examination of the glossectomy specimen. The margin status (both as a binary [positive vs negative] and continuous [distance to the margin in millimeters] variable) and other clinicopathologic parameters were compared across the 3 groups and correlated with LR. MAIN OUTCOMES AND MEASURES Local recurrence. RESULTS Age, sex, pT stage, lymphovascular or perineural invasion, and adjuvant radiation treatment were similar across the 3 groups. The probability of LR-free survival at 3 years was 0.9 and 0.8 in groups 1 and 3, respectively (P = .03). The frequency of positive glossectomy margins was lowest in group 1 (9 of 117 [7.7%]) compared with groups 2 and 3 (28 of 61 [45.9%] and 23 of 95 [24.2%], respectively) (P < .001). Even after excluding cases with positive margins, the median distance to the closest margin was significantly narrower in group 3 (2 mm) compared with group 1 (3 mm) (P = .008). The status (positive vs negative) of margins obtained from the glossectomy specimen correlated with LR (P = .007), while the status of tumor bed margins did not. The status of the tumor bed margin was 24% sensitive (95% CI, 16%-34%) and 92% specific (95% CI, 85%-97%) for detecting a positive glossectomy margin. CONCLUSIONS AND RELEVANCE The margin sampling technique affects local control in patients with oral tongue SCC. Reliance on margin sampling from the tumor bed is associated with worse local control, most likely owing to narrower margin clearance and greater incidence of positive margins. A resection specimen–based margin assessment is recommended. PMID:26225798

  9. Prostate-Specific and Tumor-Specific Targeting of an Oncolytic HSV-1 Amplicon/Helper Virus for Prostate Cancer Treatment

    DTIC Science & Technology

    2009-11-01

    that differentially expressed tumor suppressor miRNAs can be utilized to control the replication of an oncolytic DNA virus in a tumor-specific...demonstrated that the utilization of the tissue-specific promoter and the miRNA-mediated 3’UTRs in a targeted virotherapy is a viable approach with...elements into the whole HSV-1 viral genome should increase the safety margin substantially. The major advantage of the amplicon/helper system is its

  10. Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease.

    PubMed

    Ellis, Stephen G; Kereiakes, Dean J; Metzger, D Christopher; Caputo, Ronald P; Rizik, David G; Teirstein, Paul S; Litt, Marc R; Kini, Annapoorna; Kabour, Ameer; Marx, Steven O; Popma, Jeffrey J; McGreevy, Robert; Zhang, Zhen; Simonton, Charles; Stone, Gregg W

    2015-11-12

    In patients with coronary artery disease who receive metallic drug-eluting coronary stents, adverse events such as late target-lesion failure may be related in part to the persistent presence of the metallic stent frame in the coronary-vessel wall. Bioresorbable vascular scaffolds have been developed to attempt to improve long-term outcomes. In this large, multicenter, randomized trial, 2008 patients with stable or unstable angina were randomly assigned in a 2:1 ratio to receive an everolimus-eluting bioresorbable vascular (Absorb) scaffold (1322 patients) or an everolimus-eluting cobalt-chromium (Xience) stent (686 patients). The primary end point, which was tested for both noninferiority (margin, 4.5 percentage points for the risk difference) and superiority, was target-lesion failure (cardiac death, target-vessel myocardial infarction, or ischemia-driven target-lesion revascularization) at 1 year. Target-lesion failure at 1 year occurred in 7.8% of patients in the Absorb group and in 6.1% of patients in the Xience group (difference, 1.7 percentage points; 95% confidence interval, -0.5 to 3.9; P=0.007 for noninferiority and P=0.16 for superiority). There was no significant difference between the Absorb group and the Xience group in rates of cardiac death (0.6% and 0.1%, respectively; P=0.29), target-vessel myocardial infarction (6.0% and 4.6%, respectively; P=0.18), or ischemia-driven target-lesion revascularization (3.0% and 2.5%, respectively; P=0.50). Device thrombosis within 1 year occurred in 1.5% of patients in the Absorb group and in 0.7% of patients in the Xience group (P=0.13). In this large-scale, randomized trial, treatment of noncomplex obstructive coronary artery disease with an everolimus-eluting bioresorbable vascular scaffold, as compared with an everolimus-eluting cobalt-chromium stent, was within the prespecified margin for noninferiority with respect to target-lesion failure at 1 year. (Funded by Abbott Vascular; ABSORB III ClinicalTrials.gov number, NCT01751906.).

  11. An electrophysiological investigation of reinforcement effects in attention deficit/hyperactivity disorder: Dissociating cue sensitivity from down-stream effects on target engagement and performance.

    PubMed

    Chronaki, Georgia; Soltesz, Fruzsina; Benikos, Nicholas; Sonuga-Barke, Edmund J S

    2017-12-01

    Neural hypo-sensitivity to cues predicting positive reinforcement has been observed in ADHD using the Monetary Incentive Delay (MID) task. Here we report the first study using an electrophysiological analogue of this task to distinguish between (i) cue related anticipation of reinforcement and downstream effects on (ii) target engagement and (iii) performance in a clinical sample of adolescents with ADHD and controls. Thirty-one controls and 32 adolescents with ADHD aged 10-16 years performed the electrophysiological (e)-MID task - in which preparatory cues signal whether a response to an upcoming target will be reinforced or not - under three conditions; positive reinforcement, negative reinforcement (response cost) and no consequence (neutral). We extracted values for both cue-related potentials known to be, both, associated with response preparation and modulated by reinforcement (Cue P3 and Cue CNV) and target-related potentials (target P3) and compared these between ADHD and controls. ADHD and controls did not differ on cue-related components on neutral trials. Against expectation, adolescents with ADHD displayed Cue P3 and Cue CNV reinforcement-related enhancement (versus neutral trials) compared to controls. ADHD individuals displayed smaller target P3 amplitudes and slower and more variable performance - but effects were not modulated by reinforcement contingencies. When age, IQ and conduct problems were controlled effects were marginally significant but the pattern of results did not change. ADHD was associated with hypersensitivity to positive (and marginally negative) reinforcement reflected on components often thought to be associated with response preparation - however these did not translate into improved attention to targets. In the case of ADHD, upregulated CNV may be a specific marker of hyper-arousal rather than an enhancement of anticipatory attention to upcoming targets. Future studies should examine the effects of age, IQ and conduct problems on reinforcement sensitivity in ADHD. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Geometry, structure, and concealed lithology of the San Rafael Basin, southeastern Arizona

    USGS Publications Warehouse

    Bultman, Mark W.

    1999-01-01

    The contiguous United States has been well explored for exposed conventional mineral deposits. Therefore, it is likely that many economically viable and strategically significant conventional undiscovered mineral deposits will be found in bedrock concealed beneath basin sediments. Mineral resource assessments must incorporate an understanding of the geometry, structure, and concealed lithology of basins in order to be accurate. This report presents an analysis of the basin geometry and structure of the San Rafael basin in southeastern Arizona. In addition, a new methodology for inferring concealed lithology is presented and applied in the San Rafael basin. Gravity data is used to model the geometry of the basin using recent models of sediment density vs. depth developed in the region. This modeling indicates that the basin has a maximum depth of approximately 1.05 km plus or minus 0.10 km. In the southern portion, the basin can be modeled as an asymmetric graben faulted on the western margin. The northern portion of the basin is structurally more complex and may have high angle faults on the western, northern, and eastern margin. Near-ground closely spaced Earth’s total intensity magnetic field data is used to locate concealed faults within the basin. This data is also used to infer lithology concealed by shallow basin sediments. Airborne Earth’s total intensity magnetic field data is used to help infer concealed lithology in deep portions of the basin. The product of integrating all data and interpretations is a map which presents the geometry of the basin, faults and contacts concealed by basin sediments, and an estimate of the bedrock lithology concealed by basin sediment. Based on basin geometry and concealed lithology, the San Rafael basin has a high potential for concealed mineral deposits on its western and northern margin. In particular, a newly discovered magnetic anomaly in the northern portion of the basin can be modeled as a granitic intrusion with highly altered margins and may represent a potential mineral resource target. Based on the permeability and porosity of upper basin fill found in nearby basins, the San Rafael basin may contain an aquifer up to 300 meters thick over a substantial area of the basin.

  13. Alignment focus of daily image guidance for concurrent treatment of prostate and pelvic lymph nodes.

    PubMed

    Ferjani, Samah; Huang, Guangshun; Shang, Qingyang; Stephans, Kevin L; Zhong, Yahua; Qi, Peng; Tendulkar, Rahul D; Xia, Ping

    2013-10-01

    To determine the dosimetric impact of daily imaging alignment focus on the prostate soft tissue versus the pelvic bones for the concurrent treatment of the prostate and pelvic lymph nodes (PLN) and to assess whether multileaf collimator (MLC) tracking or adaptive planning (ART) is necessary with the current clinical planning margins of 8 mm/6 mm posterior to the prostate and 5 mm to the PLN. A total of 124 kilovoltage cone-beam computed tomography (kV-CBCT) images from 6 patients were studied. For each KV-CBCT, 4 plans were retrospectively created using an isocenter shifting method with 2 different alignment focuses (prostate, PLN), an MLC shifting method, and the ART method. The selected dosimetric endpoints were compared among these plans. For the isoshift contour, isoshift bone, MLC shift, and ART plans, D99 of the prostate was ≥97% of the prescription dose in 97.6%, 73.4%, 98.4%, and 96.8% of 124 fractions, respectively. Accordingly, D99 of the PLN was ≥97% of the prescription dose in 98.4%, 98.4%, 98.4%, and 100% of 124 fractions, respectively. For the rectum, D5 exceeded 105% of the planned D5 (and D5 of ART plans) in 11% (4%), 10% (2%), and 13% (5%) of 124 fractions, respectively. For the bladder, D5 exceeded 105% of the planned D5 (and D5 of ART) plans in 0% (2%), 0% (2%), and 0% (1%) of 124 fractions, respectively. For concurrent treatment of the prostate and PLN, with a planning margin to the prostate of 8 mm/6 mm posterior and a planning margin of 5 mm to the PLN, aligning to the prostate soft tissue can achieve adequate dose coverage to the both target volumes; aligning to the pelvic bone would result in underdosing to the prostate in one-third of fractions. With these planning margins, MLC tracking and ART methods have no dosimetric advantages. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Optical contrast agents to visualize molecular expression in breast cancer

    NASA Astrophysics Data System (ADS)

    Langsner, Robert James

    Breast cancer is the second leading cause of death of women in the United States. Improvements in screening technology have increased the breast cancer incidence rate, as smaller lesions are being detected. Due to the small size of lesions, patients can choose to receive breast conservation therapy (BCT) rather than a modified radical mastectomy. Even though the breast retains cosmesis after BCT, there is an increased risk of the patient having residual microscopic disease, known as positive margins. Patients with positive margins receive increased radiation and have an increased chance of second surgery. Pathology with hematoxylin and eosin (H&E) remains the gold standard for diagnosing margin status in patients. Intraoperative pathology has been shown to reduce the rate of positive margins in BCT. However, a minority of surgery centers have intraoperative pathology centers, limiting the number of patients that receive this standard of care. The expression profiles of surface receptors such as ErbB2 (HER2-positive) and epidermal growth factor receptor (EGFR) provide information about the aggressiveness of a particular tumor. Recent research has shown that there was elevated EGFR expression in patients with a local recurrence even though the biopsies were assessed to be disease free using standard H&E. If the physicians had known the molecular expression of these biopsies, a different treatment regimen or excision of more tissue might have prevented the recurrence. This thesis investigates targeted molecular contrast agents that enhance the visualization of molecular markers such as glucose transporters (GLUTs) and growth factor receptors in tissue specimens. First, application of 2-NBDG, a fluorescent deoxyglucose, enhances signal in cancerous tissue with a 20-minute incubation. Then, antibody functionalized silica-gold nanoshells enhance the visualization of ErbB2 overexpression in specimens with a 5-minute incubation. To image these contrast agents in cancerous tissue, a portable, inexpensive device was developed as a tool to help physicians visualize expression of surface markers. The system visualizes absorbance from nanoshell aggregates and fluorescence in the visible and near-infrared light spectrum. This study represents the first step in the development of an intraoperative optical imaging device to enhance the visualization of molecular markers overexpressed in cancerous cells.

  15. Are community midwives addressing the inequities in access to skilled birth attendance in Punjab, Pakistan? Gender, class and social exclusion.

    PubMed

    Mumtaz, Zubia; O'Brien, Beverley; Bhatti, Afshan; Jhangri, Gian S

    2012-09-19

    Pakistan is one of the six countries estimated to contribute to over half of all maternal deaths worldwide. To address its high maternal mortality rate, in particular the inequities in access to maternal health care services, the government of Pakistan created a new cadre of community-based midwives (CMW). A key expectation is that the CMWs will improve access to skilled antenatal and intra-partum care for the poor and disadvantaged women. A critical gap in our knowledge is whether this cadre of workers, operating in the private health care context, will meet the expectation to provide care to the poorest and most marginalized women. There is an inherent paradox between the notions of fee-for-service and increasing access to health care for the poorest who, by definition, are unable to pay. Data will be collected in three interlinked modules. Module 1 will consist of a population-based survey in the catchment areas of the CMW's in districts Jhelum and Layyah in Punjab. Proportions of socially excluded women who are served by CMWs and their satisfaction levels with their maternity care provider will be assessed. Module 2 will explore, using an institutional ethnographic approach, the challenges (organizational, social, financial) that CMWs face in providing care to the poor and socially marginalized women. Module 3 will identify the social, financial, geographical and other barriers to uncover the hidden forces and power relations that shape the choices and opportunities of poor and marginalized women in accessing CMW services. An extensive knowledge dissemination plan will facilitate uptake of research findings to inform positive developments in maternal health policy, service design and care delivery in Pakistan. The findings of this study will enhance understanding of the power dynamics of gender and class that may underlie poor women's marginalization from health care systems, including community midwifery care. One key outcome will be an increased sensitization of the special needs of socially excluded women, an otherwise invisible group. Another expectation is that the poor, socially excluded women will be targeted for provision of maternity care. The research will support the achievement of the 5th Millennium Development Goal in Pakistan.

  16. Patterns of recurrence after surgery alone versus preoperative chemoradiotherapy and surgery in the CROSS trials.

    PubMed

    Oppedijk, Vera; van der Gaast, Ate; van Lanschot, Jan J B; van Hagen, Pieter; van Os, Rob; van Rij, Caroline M; van der Sangen, Maurice J; Beukema, Jannet C; Rütten, Heidi; Spruit, Patty H; Reinders, Janny G; Richel, Dick J; van Berge Henegouwen, Mark I; Hulshof, Maarten C C M

    2014-02-10

    To analyze recurrence patterns in patients with cancer of the esophagus or gastroesophageal junction treated with either preoperative chemoradiotherapy (CRT) plus surgery or surgery alone. Recurrence pattern was analyzed in patients from the previously published CROSS I and II trials in relation to radiation target volumes. CRT consisted of five weekly courses of paclitaxel and carboplatin combined with a concurrent radiation dose of 41.4 Gy in 1.8-Gy fractions to the tumor and pathologic lymph nodes with margin. Of the 422 patients included from 2001 to 2008, 418 were available for analysis. Histology was mostly adenocarcinoma (75%). Of the 374 patients who underwent resection, 86% were allocated to surgery and 92% to CRT plus surgery. On January 1, 2011, after a minimum follow-up of 24 months (median, 45 months), the overall recurrence rate in the surgery arm was 58% versus 35% in the CRT plus surgery arm. Preoperative CRT reduced locoregional recurrence (LRR) from 34% to 14% (P < .001) and peritoneal carcinomatosis from 14% to 4% (P < .001). There was a small but significant effect on hematogenous dissemination in favor of the CRT group (35% v 29%; P = .025). LRR occurred in 5% within the target volume, in 2% in the margins, and in 6% outside the radiation target volume. In 1%, the exact site in relation to the target volume was unclear. Only 1% had an isolated infield recurrence after CRT plus surgery. Preoperative CRT in patients with esophageal cancer reduced LRR and peritoneal carcinomatosis. Recurrence within the radiation target volume occurred in only 5%, mostly combined with outfield failures.

  17. Observations at convergent margins concerning sediment subduction, subduction erosion, and the growth of continental crust

    USGS Publications Warehouse

    von Huene, Roland E.; Scholl, D. W.

    1991-01-01

    At ocean margins where two plates converge, the oceanic plate sinks or is subducted beneath an upper one topped by a layer of terrestrial crust. This crust is constructed of continental or island arc material. The subduction process either builds juvenile masses of terrestrial crust through arc volcanism or new areas of crust through the piling up of accretionary masses (prisms) of sedimentary deposits and fragments of thicker crustal bodies scraped off the subducting lower plate. At convergent margins, terrestrial material can also bypass the accretionary prism as a result of sediment subduction, and terrestrial matter can be removed from the upper plate by processes of subduction erosion. Sediment subduction occurs where sediment remains attached to the subducting oceanic plate and underthrusts the seaward position of the upper plate's resistive buttress (backstop) of consolidated sediment and rock. Sediment subduction occurs at two types of convergent margins: type 1 margins where accretionary prisms form and type 2 margins where little net accretion takes place. At type 2 margins (???19,000 km in global length), effectively all incoming sediment is subducted beneath the massif of basement or framework rocks forming the landward trench slope. At accreting or type 1 margins, sediment subduction begins at the seaward position of an active buttress of consolidated accretionary material that accumulated in front of a starting or core buttress of framework rocks. Where small-to-mediumsized prisms have formed (???16,300 km), approximately 20% of the incoming sediment is skimmed off a detachment surface or decollement and frontally accreted to the active buttress. The remaining 80% subducts beneath the buttress and may either underplate older parts of the frontal body or bypass the prism entirely and underthrust the leading edge of the margin's rock framework. At margins bordered by large prisms (???8,200 km), roughly 70% of the incoming trench floor section is subducted beneath the frontal accretionary body and its active buttress. In rounded figures the contemporary rate of solid-volume sediment subduction at convergent ocean margins (???43,500 km) is calculated to be 1.5 km3/yr. Correcting type 1 margins for high rates of terrigenous seafloor sedimentation during the past 30 m.y. or so sets the long-term rate of sediment subduction at 1.0 km3/yr. The bulk of the subducted material is derived directly or indirectly from continental denudation. Interstitial water currently expulsed from accreted and deeply subducted sediment and recycled to the ocean basins is estimated at 0.9 km3/yr. The thinning and truncation caused by subduction erosion of the margin's framework rock and overlying sedimentary deposits have been demonstrated at many convergent margins but only off northern Japan, central Peru, and northern Chile has sufficient information been collected to determine average or long-term rates, which range from 25 to 50 km3/m.y. per kilometer of margin. A conservative long-term rate applicable to many sectors of convergent margins is 30 km3/km/m.y. If applied to the length of type 2 margins, subduction erosion removes and transports approximately 0.6 km3/yr of upper plate material to greater depths. At various places, subduction erosion also affects sectors of type 1 margins bordered by small- to medium-sized accretionary prisms (for example, Japan and Peru), thus increasing the global rate by possibly 0.5 km3/yr to a total of 1.1 km3/yr. Little information is available to assess subduction erosion at margins bordered by large accretionary prisms. Mass balance calculations allow assessments to be made of the amount of subducted sediment that bypasses the prism and underthrusts the margin's rock framework. This subcrustally subducted sediment is estimated at 0.7 km3/yr. Combined with the range of terrestrial matter removed from the margin's rock framework by subduction erosion, the global volume of subcrustally subducted materia

  18. Ecological mitigation measures in English Environmental Impact Assessment.

    PubMed

    Drayson, Katherine; Thompson, Stewart

    2013-04-15

    Built development is one of the main drivers of biodiversity loss in the UK. Major built developments usually require an Environmental Impact Assessment (EIA) to be conducted, which frequently includes an Ecological Impact Assessment (EcIA) chapter. By identifying the flaws in EcIA mitigation measure proposals and their implementation in completed developments, it may be possible to develop measures to reduce biodiversity loss and help meet the UK's EU obligation to halt biodiversity loss by 2020. A review of 112 English EcIAs from 2000 onwards was conducted to provide a broad-scale overview of the information provision and detail of ecological mitigation measures. Audits of seven EIA development case study sites provided finer-scale detail of mitigation measure implementation, and the effectiveness of their grassland and marginal habitat creation and management measures was assessed using standard NVC methodology. Despite higher than expected levels of mitigation measure implementation in completed developments, EcIA mitigation proposal information and detail has seen little improvement since a 1997 review, and the effectiveness of the habitat mitigation measures studied was poor. This suggests that measures to improve ecological mitigation measures are best targeted at ecological consultants. A recommendation for EcIA-specific training of Competent Authorities is also made. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Evaluating Oilseed Biofuel Production Feasibility in California’s San Joaquin Valley Using Geophysical and Remote Sensing Techniques

    PubMed Central

    Corwin, Dennis L.; Yemoto, Kevin; Clary, Wes; Banuelos, Gary; Skaggs, Todd H.; Lesch, Scott M.

    2017-01-01

    Though more costly than petroleum-based fuels and a minor component of overall military fuel sources, biofuels are nonetheless strategically valuable to the military because of intentional reliance on multiple, reliable, secure fuel sources. Significant reduction in oilseed biofuel cost occurs when grown on marginally productive saline-sodic soils plentiful in California’s San Joaquin Valley (SJV). The objective is to evaluate the feasibility of oilseed production on marginal soils in the SJV to support a 115 ML yr−1 biofuel conversion facility. The feasibility evaluation involves: (1) development of an Ida Gold mustard oilseed yield model for marginal soils; (2) identification of marginally productive soils; (3) development of a spatial database of edaphic factors influencing oilseed yield and (4) performance of Monte Carlo simulations showing potential biofuel production on marginally productive SJV soils. The model indicates oilseed yield is related to boron, salinity, leaching fraction, and water content at field capacity. Monte Carlo simulations for the entire SJV fit a shifted gamma probability density function: Q = 68.986 + gamma (6.134,5.285), where Q is biofuel production in ML yr−1. The shifted gamma cumulative density function indicates a 0.15–0.17 probability of meeting the target biofuel-production level of 115 ML yr−1, making adequate biofuel production unlikely. PMID:29036925

  20. Cone-Beam Computed Tomography–Guided Positioning of Laryngeal Cancer Patients with Large Interfraction Time Trends in Setup and Nonrigid Anatomy Variations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gangsaas, Anne, E-mail: a.gangsaas@erasmusmc.nl; Astreinidou, Eleftheria; Quint, Sandra

    2013-10-01

    Purpose: To investigate interfraction setup variations of the primary tumor, elective nodes, and vertebrae in laryngeal cancer patients and to validate protocols for cone beam computed tomography (CBCT)-guided correction. Methods and Materials: For 30 patients, CBCT-measured displacements in fractionated treatments were used to investigate population setup errors and to simulate residual setup errors for the no action level (NAL) offline protocol, the extended NAL (eNAL) protocol, and daily CBCT acquisition with online analysis and repositioning. Results: Without corrections, 12 of 26 patients treated with radical radiation therapy would have experienced a gradual change (time trend) in primary tumor setup ≥4more » mm in the craniocaudal (CC) direction during the fractionated treatment (11/12 in caudal direction, maximum 11 mm). Due to these trends, correction of primary tumor displacements with NAL resulted in large residual CC errors (required margin 6.7 mm). With the weekly correction vector adjustments in eNAL, the trends could be largely compensated (CC margin 3.5 mm). Correlation between movements of the primary and nodal clinical target volumes (CTVs) in the CC direction was poor (r{sup 2}=0.15). Therefore, even with online setup corrections of the primary CTV, the required CC margin for the nodal CTV was as large as 6.8 mm. Also for the vertebrae, large time trends were observed for some patients. Because of poor CC correlation (r{sup 2}=0.19) between displacements of the primary CTV and the vertebrae, even with daily online repositioning of the vertebrae, the required CC margin around the primary CTV was 6.9 mm. Conclusions: Laryngeal cancer patients showed substantial interfraction setup variations, including large time trends, and poor CC correlation between primary tumor displacements and motion of the nodes and vertebrae (internal tumor motion). These trends and nonrigid anatomy variations have to be considered in the choice of setup verification protocol and planning target volume margins. eNAL could largely compensate time trends with minor prolongation of fraction time.« less

  1. WE-G-BRD-08: Motion Analysis for Rectal Cancer: Implications for Adaptive Radiotherapy On the MR-Linac

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kleijnen, J; Asselen, B van; Burbach, M

    2015-06-15

    Purpose: Purpose of this study is to find the optimal trade-off between adaptation interval and margin reduction and to define the implications of motion for rectal cancer boost radiotherapy on a MR-linac. Methods: Daily MRI scans were acquired of 16 patients, diagnosed with rectal cancer, prior to each radiotherapy fraction in one week (N=76). Each scan session consisted of T2-weighted and three 2D sagittal cine-MRI, at begin (t=0 min), middle (t=9:30 min) and end (t=18:00 min) of scan session, for 1 minute at 2 Hz temporal resolution. Tumor and clinical target volume (CTV) were delineated on each T2-weighted scan andmore » transferred to each cine-MRI. The start frame of the begin scan was used as reference and registered to frames at time-points 15, 30 and 60 seconds, 9:30 and 18:00 minutes and 1, 2, 3 and 4 days later. Per time-point, motion of delineated voxels was evaluated using the deformation vector fields of the registrations and the 95th percentile distance (dist95%) was calculated as measure of motion. Per time-point, the distance that includes 90% of all cases was taken as estimate of required planning target volume (PTV)-margin. Results: Highest motion reduction is observed going from 9:30 minutes to 60 seconds. We observe a reduction in margin estimates from 10.6 to 2.7 mm and 16.1 to 4.6 mm for tumor and CTV, respectively, when adapting every 60 seconds compared to not adapting treatment. A 75% and 71% reduction, respectively. Further reduction in adaptation time-interval yields only marginal motion reduction. For adaptation intervals longer than 18:00 minutes only small motion reductions are observed. Conclusion: The optimal adaptation interval for adaptive rectal cancer (boost) treatments on a MR-linac is 60 seconds. This results in substantial smaller PTV-margin estimates. Adaptation intervals of 18:00 minutes and higher, show little improvement in motion reduction.« less

  2. Significant Reduction of Late Toxicities in Patients With Extremity Sarcoma Treated With Image-Guided Radiation Therapy to a Reduced Target Volume: Results of Radiation Therapy Oncology Group RTOG-0630 Trial.

    PubMed

    Wang, Dian; Zhang, Qiang; Eisenberg, Burton L; Kane, John M; Li, X Allen; Lucas, David; Petersen, Ivy A; DeLaney, Thomas F; Freeman, Carolyn R; Finkelstein, Steven E; Hitchcock, Ying J; Bedi, Manpreet; Singh, Anurag K; Dundas, George; Kirsch, David G

    2015-07-10

    We performed a multi-institutional prospective phase II trial to assess late toxicities in patients with extremity soft tissue sarcoma (STS) treated with preoperative image-guided radiation therapy (IGRT) to a reduced target volume. Patients with extremity STS received IGRT with (cohort A) or without (cohort B) chemotherapy followed by limb-sparing resection. Daily pretreatment images were coregistered with digitally reconstructed radiographs so that the patient position could be adjusted before each treatment. All patients received IGRT to reduced tumor volumes according to strict protocol guidelines. Late toxicities were assessed at 2 years. In all, 98 patients were accrued (cohort A, 12; cohort B, 86). Cohort A was closed prematurely because of poor accrual and is not reported. Seventy-nine eligible patients from cohort B form the basis of this report. At a median follow-up of 3.6 years, five patients did not have surgery because of disease progression. There were five local treatment failures, all of which were in field. Of the 57 patients assessed for late toxicities at 2 years, 10.5% experienced at least one grade ≥ 2 toxicity as compared with 37% of patients in the National Cancer Institute of Canada SR2 (CAN-NCIC-SR2: Phase III Randomized Study of Pre- vs Postoperative Radiotherapy in Curable Extremity Soft Tissue Sarcoma) trial receiving preoperative radiation therapy without IGRT (P < .001). The significant reduction of late toxicities in patients with extremity STS who were treated with preoperative IGRT and absence of marginal-field recurrences suggest that the target volumes used in the Radiation Therapy Oncology Group RTOG-0630 (A Phase II Trial of Image-Guided Preoperative Radiotherapy for Primary Soft Tissue Sarcomas of the Extremity) study are appropriate for preoperative IGRT for extremity STS. © 2015 by American Society of Clinical Oncology.

  3. Effect of resealing on microleakage of resin composite restorations in relationship to margin design and composite type

    PubMed Central

    Antonson, Sibel A.; Yazici, A. Ruya; Okte, Zeynep; Villalta, Patricia; Antonson, Donald E.; Hardigan, Patrick C.

    2012-01-01

    Objective: To determine the relationship between margin preparation design and resin-composite type on microleakage with or without re-application of surface-penetrating sealant. Methods: Class-I resin-composite restorations were completed for 128 extracted human molars. Half of the margins were beveled, the other half, butt-joint. Half of each group was restored with Filtek-Supreme (FS), the other half with Esthet-X (EX) using their respective adhesive systems. Margins were etched and sealed with a surface-penetrating sealant, Fortify. The samples were stored in water 24h, and thermocycled (5,000 cycles, 5°C–55°C). Then, samples were abraded using a toothbrush machine (6,000 strokes). Half of the restorations from each sealant group (n=16) were resealed, and the other half had no further treatment. Thermocycling and tooth brushing were repeated. The samples were sealed with nail polish, immersed in methylene-blue for 8h, sectioned, and magnified digital photographs were taken. Three examiners assessed dye penetration. A 2×2×2 multi-layered Chi-Square analysis, using Cochran-Mantel-Haenszel test was conducted for statistical analysis. Results: No difference was observed between sealed and resealed FS and EX restorations with butt-joint margins. In beveled margins, resealing caused significantly less microleakage (P<.01). No differences were found between restorations either sealed or resealed with bevel margins. In butt-joint margins, at the leakage level deeper than 2/3 of the preparation depth, resealed FS showed less microleakage than EX resealed restorations (P<.01). Conclusion: Resealing reduced microleakage in bevel margins, however, in butt-joint margins resealing did not affect the leakage. A significant statistical relationship exists between and within resealing, margin preparation design, type of composite, and microleakage. PMID:23077418

  4. Quantitative measurement of marginal disintegration of ceramic inlays.

    PubMed

    Hayashi, Mikako; Tsubakimoto, Yuko; Takeshige, Fumio; Ebisu, Shigeyuki

    2004-01-01

    The objectives of this study include establishing a method for quantitative measurement of marginal change in ceramic inlays and clarifying their marginal disintegration in vivo. An accurate CCD optical laser scanner system was used for morphological measurement of the marginal change of ceramic inlays. The accuracy of the CCD measurement was assessed by comparing it with microscopic measurement. Replicas of 15 premolars restored with Class II ceramic inlays at the time of placement and eight years after restoration were used for morphological measurement by means of the CCD laser scanner system. Occlusal surfaces of the restored teeth were scanned and cross-sections of marginal areas were computed with software. Marginal change was defined as the area enclosed by two profiles obtained by superimposing two cross-sections of the same location at two different times and expressing the maximum depth and mean area of the area enclosed. The accuracy of this method of measurement was 4.3 +/- 3.2 microm in distance and 2.0 +/- 0.6% in area. Quantitative marginal changes for the eight-year period were 10 x 10 microm in depth and 50 x 10(3) microm2 in area at the functional cusp area and 7 x 10 microm in depth and 28 x 10(3) microm2 in area at the non-functional cusp area. Marginal disintegration at the functional cusp area was significantly greater than at the non-functional cusp area (Wilcoxon signed-ranks test, p < 0.05). This study constitutes a quantitative measurement of in vivo deterioration in marginal adaptation of ceramic inlays and indicates that occlusal force may accelerate marginal disintegration.

  5. Fabricating multifunctional microbubbles and nanobubbles for concurrent ultrasound and photoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Qin, Ruogu; Xu, Jeff; Xu, Ronald; Kim, Chulhong; Wang, Lihong V.

    2010-02-01

    Background: Clinical ultrasound (US) uses ultrasonic scattering contrast to characterize subcutaneous anatomic structures. Photoacoustic (PA) imaging detects the functional properties of thick biological tissue with high optical contrast. In the case of image-guided cancer ablation therapy, simultaneous US and PA imaging can be useful for intraoperative assessment of tumor boundaries and ablation margins. In this regard, accurate co-registration between imaging modalities and high sensitivity to cancer cells are important. Methods: We synthesized poly-lactic-co-glycolic acid (PLGA) microbubbles (MBs) and nanobubbles (NBs) encapsulating India ink or indocyanine green (ICG). Multiple tumor simulators were fabricated by entrapping ink MBs or NBs at various concentrations in gelatin phantoms for simultaneous US and PA imaging. MBs and NBs were also conjugated with CC49 antibody to target TAG-72, a human glycoprotein complex expressed in many epithelial-derived cancers. Results: Accurate co-registration and intensity correlation were observed in US and PA images of MB and NB tumor simulators. MBs and NBs conjugating with CC49 effectively bound with over-expressed TAG-72 in LS174T colon cancer cell cultures. ICG was also encapsulated in MBs and NBs for the potential to integrate US, PA, and fluorescence imaging. Conclusions: Multifunctional MBs and NBs can be potentially used as a general contrast agent for multimodal intraoperative imaging of tumor boundaries and therapeutic margins.

  6. Prevention of Radiochemotherapy-Induced Esophagitis With Glutamine: Results of a Pilot Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Algara, Manuel; Universitat Pompeu Fabra, Barcelona; Rodriguez, Nuria

    2007-10-01

    Purpose: To assess the usefulness of oral glutamine to prevent radiochemotherapy-induced esophagitis in patients with lung cancer, and to determine the dosimetric parameter predictive of esophagitis. Methods and Materials: Seventy-five patients were enrolled; 34.7% received sequential radiochemotherapy, and 65.3% received concomitant radiochemotherapy. Every patient received prophylactic glutamine powder in doses of 10 g/8 h. Prescribed radiation doses were 45-50 Gy to planning target volume (PTV)1 (gross tumor volume plus wide margins) and 65-70 Gy to PTV2 (reduced margins). The primary endpoint was the incidence of Grade 2 or greater acute esophagitis. Results: No patient experienced glutamine intolerance or glutamine-related toxicity.more » Seventy-three percent of patients who received sequential chemotherapy and 49% of those who received concomitant chemotherapy did not present any form of esophagitis. V50 was the dosimetric parameter with better correlation between esophagitis and its duration. A V50 of {<=}30% had a 22% risk of esophagitis Grade {>=}2, which increased to 71% with a V50 of >30% (p = 0.0009). Conclusions: The use of oral glutamine may have an important role in the prevention of esophageal complications of concomitant radiochemotherapy in lung cancer patients. However, randomized trials are needed to corroborate that effect. V50 is the dosimetric parameter with better correlation with esophagitis grade and duration.« less

  7. Deep-sea crustacean trawling fisheries in Portugal: quantification of effort and assessment of landings per unit effort using a Vessel Monitoring System (VMS)

    NASA Astrophysics Data System (ADS)

    Bueno-Pardo, Juan; Ramalho, Sofia P.; García-Alegre, Ana; Morgado, Mariana; Vieira, Rui P.; Cunha, Marina R.; Queiroga, Henrique

    2017-01-01

    Mapping and quantifying bottom trawling fishing pressure on the seafloor is pivotal to understand its effects on deep-sea benthic habitats. Using data from the Vessel Monitoring System of crustacean trawlers along the Portuguese margin, we have identified the most exploited areas and characterized the most targeted habitats and water depths. We estimated a total trawling effort of 69596, 66766, and 63427 h y-1 for the years 2012, 2013, and 2014 respectively which, considering the total landings estimated for this gear, yield values of 20.76, 21.06, and 19.11 kg of landed fish per trawled hour. The main trawling pressure is exerted in the South and Southwest Portuguese margins, on muddy and muddy-sand bottoms between 200 and 700 m water depths, while in the North and Central-West coasts a minor effort, at shallower waters and across a wider range of habitats, is also applied. The most landed species are crustaceans such as rose shrimp and Norway lobster, although this varies importantly between the different regions of Portugal, being fish and cephalopods the main captures in the Northern ports. We discuss the consequences of trawling for the impacted communities as well as the characteristics of the commercialization of these captures in Portugal.

  8. A Tale of Two Cities: Access to Care and Services Among African-American Transgender Women in Oakland and San Francisco

    PubMed Central

    Cruz, Taylor M.; Iwamoto, Mariko; Sakata, Maria

    2015-01-01

    Abstract Purpose: The San Francisco Bay Area attracts people from all over the country due to the perception of lesbian, gay, bisexual, and transgender (LGBT) acceptance and affirmation. African-American transgender women are severely marginalized across society and as such have many unmet health and social service needs. This study sought to quantitatively assess unmet needs among African-American transgender women with a history of sex work by comparing residents of Oakland versus San Francisco. Methods: A total of 235 African-American transgender women were recruited from San Francisco (n=112) and Oakland (n=123) through community outreach and in collaboration with AIDS service organizations. Participants were surveyed regarding basic, health, and social needs and HIV risk behaviors. Pearson Chi-squared tests and a linear regression model examined associations between city of residence and unmet needs. Results: While participants from both cities reported unmet needs, Oakland participants had a greater number of unmet needs in receiving basic assistance, mental health treatment, and health care services. Oakland participants also reported less transgender community identification but higher social support from the family. Conclusion: These findings demonstrate the enormity of African-American transgender women's needs within the Bay Area. Greater resources are needed for social service provision targeting this marginalized group of people, particularly in Oakland. PMID:26788672

  9. Morphologic and Functional Effects of Gamma Secretase Inhibition on Splenic Marginal Zone B Cells

    PubMed Central

    de Vera Mudry, Maria Cristina; Regenass-Lechner, Franziska; Ozmen, Laurence; Altmann, Bernd; Festag, Matthias; Singer, Thomas; Müller, Lutz; Jacobsen, Helmut; Flohr, Alexander

    2012-01-01

    The γ-secretase complex is a promising target in Alzheimer's disease because of its role in the amyloidogenic processing of β-amyloid precursor protein. This enzyme also catalyzes the cleavage of Notch receptor, resulting in the nuclear translocation of intracellular Notch where it modulates gene transcription. Notch signaling is essential in cell fate decisions during embryogenesis, neuronal differentiation, hematopoiesis, and development of T and B cells, including splenic marginal zone (MZ) B cells. This B cell compartment participates in the early phases of the immune response to blood-borne bacteria and viruses. Chronic treatment with the oral γ-secretase inhibitor RO4929097 resulted in dose-dependent decreased cellularity (atrophy) of the MZ of rats and mice. Significant decreases in relative MZ B-cell numbers of RO4929097-treated animals were confirmed by flow cytometry. Numbers of MZ B cells reverted to normal after a sufficient RO4929097-free recovery period. Functional characterization of the immune response in relation to RO4929097-related MZ B cell decrease was assessed in mice vaccinated with inactivated vesicular stomatitis virus (VSV). Compared with the immunosuppressant cyclosporin A, RO4929097 caused only mild and reversible delayed early neutralizing IgM and IgG responses to VSV. Thus, the functional consequence of MZ B cell decrease on host defense is comparatively mild. PMID:23316412

  10. Deep-sea crustacean trawling fisheries in Portugal: quantification of effort and assessment of landings per unit effort using a Vessel Monitoring System (VMS)

    PubMed Central

    Bueno-Pardo, Juan; Ramalho, Sofia P.; García-Alegre, Ana; Morgado, Mariana; Vieira, Rui P.; Cunha, Marina R.; Queiroga, Henrique

    2017-01-01

    Mapping and quantifying bottom trawling fishing pressure on the seafloor is pivotal to understand its effects on deep-sea benthic habitats. Using data from the Vessel Monitoring System of crustacean trawlers along the Portuguese margin, we have identified the most exploited areas and characterized the most targeted habitats and water depths. We estimated a total trawling effort of 69596, 66766, and 63427 h y−1 for the years 2012, 2013, and 2014 respectively which, considering the total landings estimated for this gear, yield values of 20.76, 21.06, and 19.11 kg of landed fish per trawled hour. The main trawling pressure is exerted in the South and Southwest Portuguese margins, on muddy and muddy-sand bottoms between 200 and 700 m water depths, while in the North and Central-West coasts a minor effort, at shallower waters and across a wider range of habitats, is also applied. The most landed species are crustaceans such as rose shrimp and Norway lobster, although this varies importantly between the different regions of Portugal, being fish and cephalopods the main captures in the Northern ports. We discuss the consequences of trawling for the impacted communities as well as the characteristics of the commercialization of these captures in Portugal. PMID:28098211

  11. Accuracy of experimental mandibular osteotomy using the image-guided sagittal saw.

    PubMed

    Pietruski, P; Majak, M; Swiatek-Najwer, E; Popek, M; Szram, D; Zuk, M; Jaworowski, J

    2016-06-01

    The aim of this study was to perform an objective assessment of the accuracy of mandibular osteotomy simulations performed using an image-guided sagittal saw. A total of 16 image-guided mandibular osteotomies were performed on four prefabricated anatomical models according to the virtual plan. Postoperative computed tomography (CT) image data were fused with the preoperative CT scan allowing an objective comparison of the results of the osteotomy executed with the virtual plan. For each operation, the following parameters were analyzed and compared independently twice by two observers: resected bone volume, osteotomy trajectory angle, and marginal point positions. The mean target registration error was 0.95±0.19mm. For all osteotomies performed, the mean difference between the planned and actual bone resection volumes was 8.55±5.51%, the mean angular deviation between planned and actual osteotomy trajectory was 8.08±5.50°, and the mean difference between the preoperative and the postoperative marginal point positions was 2.63±1.27mm. In conclusion, despite the initial stages of the research, encouraging results were obtained. The current limitations of the navigated saw are discussed, as well as the improvements in technology that should increase its predictability and efficiency, making it a reliable method for improving the surgical outcomes of maxillofacial operations. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Impact of using different four-dimensional computed tomography data sets to design proton treatment plans for distal esophageal cancer.

    PubMed

    Pan, Xiaoning; Zhang, Xiaodong; Li, Yupeng; Mohan, Radhe; Liao, Zhongxing

    2009-02-01

    To study the impact of selecting different data sets from four-dimensional computed tomography (4D CT) imaging during proton treatment planning in patients with distal esophageal cancer. We examined the effects of changes in 4D CT data set and smearing margins in proton treatment planning for 5 patients with distal esophageal cancer whose diaphragms were in the beam path and could move several centimeters during respiration. Planning strategies based on (1) average, (2) inspiration, and (3) expiration CT were evaluated in terms of their coverage on the internal clinic target volume (ICTV) at the prescribed dose. For Strategy 1, increasing the smearing margin caused an increase in the ICTV prescription dose coverage (PDC) at the end-exhalation phase for all patients, whereas the ICTV PDC decreased for some patients at the end-inhalation phase. For Strategy 2, a smearing margin in the range of 1.0 to 3.5 cm caused the ICTV PDC to remain essentially unchanged, regardless of which phase of 4D CT was used for dose calculation, for all patients. For Strategy 3, the ICTV coverage was adequate for 2 of the 5 patients when a smearing margin of less than 1.0 cm was used, but was not adequate for the other 3 patients regardless of the smearing margin. Using the inspiration CT plus a smearing margin can lead to adequate ICTV coverage in treatment plans for patients with distal esophageal tumors surrounded by tissue that is subject to large changes in density during a proton treatment.

  13. Recent technological developments: in situ histopathological interrogation of surgical tissues and resection margins

    PubMed Central

    Upile, Tahwinder; Fisher, Cyril; Jerjes, Waseem; El Maaytah, Mohammed; Singh, Sandeep; Sudhoff, Holger; Searle, Adam; Archer, Daniel; Michaels, Leslie; Hopper, Colin; Rhys-Evans, Peter; Howard, David; Wright, Anthony

    2007-01-01

    Objectives The tumour margin is an important surgical concept significantly affecting patient morbidity and mortality. We aimed in this prospective study to apply the microendoscope on tissue margins from patients undergoing surgery for oral cancer in vivo and ex vivo and compare it to the gold standard "paraffin wax", inter-observer agreement was measured; also to present the surgical pathologist with a practical guide to the every day use of the microendoscope both in the clinical and surgical fields. Materials and methods Forty patients undergoing resection of oral squamous cell carcinoma were recruited. The surgical margin was first marked by the operator followed by microendoscopic assessment. Biopsies were taken from areas suggestive of close or positive margins after microendoscopic examination. These histological samples were later scrutinized formally and the resection margins revisited accordingly when necessary. Results Using the microendoscope we report our experience in the determination of surgical margins at operation and later comparison with frozen section and paraffin section margins "gold standard". We were able to obtain a sensitivity of 95% and a specificity of 90%. Inter-observer Kappa scores comparing the microendoscope with formal histological analysis of normal and abnormal mucosa were 0.85. Conclusion The advantage of this technique is that a large area of mucosa can be sampled and any histomorphological changes can be visualized in real time allowing the operator to make important informed decisions with regards the intra-operative resection margin at the time of the surgery. PMID:17331229

  14. Educating the Heart and the Mind: Conceptualizing Inclusive Pedagogy for Sustainable Development

    ERIC Educational Resources Information Center

    Mukherjee, Mousumi

    2017-01-01

    There is growing global consensus that inequality is making sustainable development goals unattainable. Social inclusion of the historically marginalized and equality of opportunity is crucial for sustainable development. Inclusive quality education for all is therefore considered as one of the three main targets for sustainable development…

  15. Exploring the Relationships between Dialogue and Inclusive School Communities

    ERIC Educational Resources Information Center

    Orzel, Courtney Leigh

    2012-01-01

    High standards and expectations for all students drive current school reform efforts which target accountability measures and focus on standardized tests, leaving many American students, particularly those who have been traditionally underserved and marginalized, feeling excluded and silenced in school. Thus, it is important for school leaders to…

  16. Children's Food Security and Intakes from School Meals. Final Report. Contractor and Cooperator Report No. 61

    ERIC Educational Resources Information Center

    Potamites, Elizabeth; Gordon, Anne

    2010-01-01

    Using 2005 data from the U.S. Department of Agriculture's Third School Nutrition Dietary Assessment survey, this study examines the contribution of school meals to the food and nutrient intake of children in food-secure, marginally secure, and food-insecure households. The study finds that children from food-insecure and marginally secure…

  17. Defining and Assessing Parent Empowerment and Its Relationship to Academic Achievement Using the National Household Education Survey: A Focus on Marginalized Parents

    ERIC Educational Resources Information Center

    Kim, Jungnam

    2012-01-01

    Marginalized parents experience multiple and complex challenges in terms of social isolation, exclusion, and powerlessness. This empirical study investigated the effects of parent empowerment on academic outcomes using a large national representative sample and should provide insights about the importance of parent empowerment in education and…

  18. Young People on the Margins of the Educational System: Following the Same Path Differently

    ERIC Educational Resources Information Center

    Görlich, Anne; Katznelson, Noemi

    2018-01-01

    Background: Across Europe and the Nordic countries, unemployment among 18-30 year-olds is a major challenge, which in some countries is being tackled by focusing on education. In Denmark, young unemployed people or people on the margins of the education system are assessed regarding what is known as an "education requirement". Hence,…

  19. Targeted therapies for the treatment of leukemia.

    PubMed

    Stull, Dawn Marie

    2003-05-01

    To review novel targeted therapies for the treatment of leukemia. Professional journals, books, and government publications. Nonspecific cytotoxic chemotherapeutic agents provide marginal therapeutic benefit and significant toxicity when used in the treatment of leukemia. There is a tremendous need for new therapies with increased efficacy and decreased adverse effects. Advances in molecular science, genetics, and immunology, along with improved laboratory technology, have led to the discovery of unique targets integral to the growth and proliferation of malignant cells which are providing the foundation for the development of a new generation of antitumor agents. Nurses must be prepared to educate patients, administer novel therapies, and manage side effects.

  20. A novel approach for evaluation of prostate deformation and associated dosimetric implications in IGRT of the prostate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mayyas, Essa, E-mail: emayyas1@hfhs.org, E-mail: ortonc@comcast.net; Kim, Jinkoo; Kumar, Sanath

    2014-09-15

    Purpose: Prostate deformation is assumed to be a secondary correction and is typically ignored in the planning target volume (PTV) margin calculations. This assumption needs to be tested, especially when planning margins are reduced with daily image-guidance. In this study, deformation characteristics of the prostate and seminal vesicles were determined, and the dosimetric impact on treatment plans with different PTV margins was investigated. Methods: Ten prostate cancer patients were retrospectively selected for the study, each with three fiducial markers implanted in the prostate. Two hundred CBCT images were registered to respective planning CT images using a B-spline-based deformable image registrationmore » (DIR) software. A manual bony anatomy-based match was first applied based on the alignment of the pelvic bones and fiducial landmarks. DIR was then performed. For each registration, deformation vector fields (DVFs) of the prostate and seminal vesicles (SVs) were quantified using deformation-volume histograms. In addition, prostate rotation was evaluated and compared with prostate deformation. For a patient demonstrating small and large prostate deformations, target coverage degradation was analyzed in each of three treatment plans with PTV margins of 10 mm (6 mm at the prostate/rectum interface), as well as 5, and 3 mm uniformly. Results: Deformation of the prostate was most significant in the anterior direction. Maximum prostate deformation of greater than 10, 5, and 3 mm occurred in 1%, 17%, and 76% of the cases, respectively. Based on DVF-histograms, DVF magnitudes greater than 5 and 3 mm occurred in 2% and 27% of the cases, respectively. Deformation of the SVs was most significant in the posterior direction, and it was greater than 5 and 3 mm in 7.5% and 44.9% of the cases, respectively. Prostate deformation was found to be poorly correlated with rotation. Fifty percent of the cases showed rotation with negligible deformation and 7% of the cases showed significant deformation with minimal rotation (<3°). Average differences in the D{sub 95} dose to the prostate + SVs between the planning CT and CBCT images was 0.4% ± 0.5%, 3.0% ± 2.8%, and 6.6% ± 6.1%, respectively, for the plans with 10/6, 5, and 3 mm margins. For the case with both a large degree of prostate deformation (≈10% of the prostate volume) and rotation (≈8°), D{sub 95} was reduced by 0.5% ± 0.1%, 6.8% ± 0.6%, and 20.9% ± 1.6% for 10/6, 5, and 3 mm margin plans, respectively. For the case with large prostate deformation but negligible rotation (<1°), D{sub 95} was reduced by 0.4 ± 0.3, 3.9 ± 1.0, and 11.5 ± 2.5 for 10/6, 5, and 3 mm margin plans, respectively. Conclusions: Prostate deformation over a course of fractionated prostate radiotherapy may not be insignificant and may need to be accounted for in the planning margin design. A consequence of these results is that use of highly reduced planning margins must be viewed with caution.« less

  1. Impact of a maternal health voucher scheme on institutional delivery among low income women in Pakistan.

    PubMed

    Agha, Sohail

    2011-05-03

    Only 39% of deliveries in Pakistan are attended by skilled birth attendants, while Pakistan's target for skilled birth attendance by 2015 is > 90%. A 12-month maternal health voucher intervention was implemented in Dera Ghazi Khan City, located in Southern Punjab, Pakistan in 2009. A pre-test/post-test non-experimental study was conducted to assess the impact of the intervention. Household interviews were conducted with randomly selected women who delivered in 2008 (the year prior to the voucher intervention), and with randomly selected women who delivered in 2009. A strong outreach model was used and voucher booklets valued at $50, containing redeemable coupons for three antenatal care (ANC) visits, a postnatal care (PNC) visit and institutional delivery, were sold for $1.25 to low-income women targeted by project workers. Regression analysis was conducted to determine the impact of the voucher scheme on ANC, PNC, and institutional delivery. Marginal effects estimated from logistic regression analyses were used to assess the magnitude of the impact of the intervention. The women targeted by voucher outreach workers were poorer, less educated, and at higher parity. After adjusting for these differences, women who delivered in 2009 and were sold voucher booklets were significantly more likely than women who delivered in 2008 to make at least three ANC visits, deliver in a health facility, and make a postnatal visit. Purchase of a voucher booklet was associated with a 22 percentage point increase in ANC use, a 22 percentage point increase in institutional delivery, and a 35 percentage point increase in PNC use. A voucher intervention implemented for 12 months was associated with a substantial increase in institutional delivery. A substantial scale-up of maternal health vouchers that focus on institutional delivery is likely to bring Pakistan closer to achieving its 2015 target for institutional delivery.

  2. Spacelab simulation using a Lear Jet aircraft: Mission no. 4 (ASSESS program)

    NASA Technical Reports Server (NTRS)

    Reller, J. O., Jr.; Neel, C. B.; Mason, R. H.

    1975-01-01

    The fourth ASSESS Spacelab simulation mission utilizing a Lear Jet aircraft featured trained experiment operators (EOs) in place of the participating scientists, to simulate the role and functions of payload specialists in Spacelab who may conduct experiments developed by other scientists. The experiment was a broadband infrared photometer coupled to a 30-cm, open port, IR telescope. No compromises in equipment design or target selection were made to simplify operator tasks; the science goals of the mission were selected to advance the mainline research program of the principle investigator (PI). Training of the EOs was the responsibility of the PI team and consisted of laboratory sessions, on-site training during experiment integration, and integrated mission training using the aircraft as a high-fidelity simulator. The EO permission experience in these several disciplines proved adequate for normal experiment operations, but marginal for the identification and remedy of equipment malfunctions. During the mission, the PI utilized a TV communication system to assist the EOs to overcome equipment difficulties; both science and operations were successfully implemented.

  3. SU-E-T-224: Considerations for the Proper Treatment of Multiple Cranial Metastases with Single Isocenter Volumetric Modulated Arc Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Audet, C; Poffenbarger, B; Hwang, A

    2015-06-15

    Purpose: To investigate some limitations of single isocenter VMAT for cranial multiple met cases. Methods: A single isocenter VMAT plan (Varian, Eclipse AAA10 commissioned down to 1 cm) was designed for two 7mm diameter spherical targets in a rectangular Solid Water (Gammex) phantom. The targets were separated by a distance of 6cm and the isocenter was centered in one of the targets. The plan was delivered (Varian, Truebeam STx) three separate times with different artificial couch angle errors of 0, 0.5 and 1 degree. The coronal dose distributions were measured with calibrated EBT3 film placed at mid-phantom. EBT3 film dosimetrymore » was also performed on the delivery of separate multiple arc vmat plans to targets below 6mm in diameter. Results: Measurements of the sup/inf dose profiles through the high dose distributions show no movement of the central axis high dose region and shifts of the high dose region intended for the off-axis target. For the 1 degree rotation error, the high dose region was shifted 1.04mm from the target. This corresponds to the shift expected from triangulation (60mmxTan(1deg)=1.047mm). Furthermore, a streak of 10% interleaf leakage dose was observed and is likely a Result of the off axis target traveling a wide path such that a long length of MLC is exposed for the whole arc. The calculated dose was about 10% to 15% low compared to that measured on film for a 5mm diameter target. Conclusion: Judicious use of additional margin for off axis targets or limits on the span of multiple mets treated with one isocenter is recommended. The magnitude of the margin should be based on the rotational errors evaluated for the positioning system and the distance of the target from the isocenter. A lower limit of lesion size that can be accurately treated with VMAT should be determined.« less

  4. SU-F-J-24: Setup Uncertainty and Margin of the ExacTrac 6D Image Guide System for Patients with Brain Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, S; Oh, S; Yea, J

    Purpose: This study evaluated the setup uncertainties for brain sites when using BrainLAB’s ExacTrac X-ray 6D system for daily pretreatment to determine the optimal planning target volume (PTV) margin. Methods: Between August 2012 and April 2015, 28 patients with brain tumors were treated by daily image-guided radiotherapy using the BrainLAB ExacTrac 6D image guidance system of the Novalis-Tx linear accelerator. DUONTM (Orfit Industries, Wijnegem, Belgium) masks were used to fix the head. The radiotherapy was fractionated into 27–33 treatments. In total, 844 image verifications were performed for 28 patients and used for the analysis. The setup corrections along with themore » systematic and random errors were analyzed for six degrees of freedom in the translational (lateral, longitudinal, and vertical) and rotational (pitch, roll, and yaw) dimensions. Results: Optimal PTV margins were calculated based on van Herk et al.’s [margin recipe = 2.5∑ + 0.7σ − 3 mm] and Stroom et al.’s [margin recipe = 2∑ + 0.7σ] formulas. The systematic errors (∑) were 0.72, 1.57, and 0.97 mm in the lateral, longitudinal, and vertical translational dimensions, respectively, and 0.72°, 0.87°, and 0.83° in the pitch, roll, and yaw rotational dimensions, respectively. The random errors (σ) were 0.31, 0.46, and 0.54 mm in the lateral, longitudinal, and vertical rotational dimensions, respectively, and 0.28°, 0.24°, and 0.31° in the pitch, roll, and yaw rotational dimensions, respectively. According to van Herk et al.’s and Stroom et al.’s recipes, the recommended lateral PTV margins were 0.97 and 1.66 mm, respectively; the longitudinal margins were 1.26 and 3.47 mm, respectively; and the vertical margins were 0.21 and 2.31 mm, respectively. Conclusion: Therefore, daily setup verifications using the BrainLAB ExacTrac 6D image guide system are very useful for evaluating the setup uncertainties and determining the setup margin.∑σ.« less

  5. Enhancing Ignition Probability and Fusion Yield in NIF Indirect Drive Targets with Applied Magnetic Fields

    NASA Astrophysics Data System (ADS)

    Perkins, L. John; Logan, B. Grant; Ho, Darwin; Zimmerman, George; Rhodes, Mark; Blackfield, Donald; Hawkins, Steven

    2017-10-01

    Imposed magnetic fields of tens of Tesla that increase to greater than 10 kT (100 MGauss) under capsule compression may relax conditions for ignition and propagating burn in indirect-drive ICF targets. This may allow attainment of ignition, or at least significant fusion energy yields, in presently-performing ICF targets on the National Ignition Facility that today are sub-marginal for thermonuclear burn through adverse hydrodynamic conditions at stagnation. Results of detailed 2D radiation-hydrodynamic-burn simulations applied to NIF capsule implosions with low-mode shape perturbations and residual kinetic energy loss indicate that such compressed fields may increase the probability for ignition through range reduction of fusion alpha particles, suppression of electron heat conduction and stabilization of higher-mode RT instabilities. Optimum initial applied fields are around 50 T. Off-line testing has been performed of a hohlraum coil and pulsed power supply that could be integrated on NIF; axial fields of 58T were obtained. Given the full plasma structure at capsule stagnation may be governed by 3-D resistive MHD, the formation of closed magnetic field lines might further augment ignition prospects. Experiments are now required to assess the potential of applied magnetic fields to NIF ICF ignition and burn. Work performed under auspices of U.S. DOE by LLNL under Contract DE-AC52-07NA27344.

  6. Cost-utility of universal hepatitis A vaccination in Canada.

    PubMed

    Bauch, C T; Anonychuk, A M; Pham, B Z; Gilca, V; Duval, B; Krahn, M D

    2007-12-12

    Hepatitis A (HA) vaccination in Canada is currently targeted toward high-risk groups. The cost-effectiveness and expected health outcomes of universal vaccination relative to targeted vaccination in low-incidence countries such as Canada are currently unknown. Here, we conducted a cost-utility analysis for this situation, with Canada as the study population. We included vaccine costs, time costs, infection costs, and public health costs. We assessed a range of possible universal vaccination strategies over an 80-year time horizon using multiple cost perspectives. A dynamic model was used to account for herd immunity. Aggregate health gains from switching to universal vaccination are modest (10-30 QALYs per year). However, a "9+9" strategy that replaces two doses of monovalent hepatitis B (HB) vaccine at 9/10 years (universally administered in most provinces) with two doses of bivalent HA/HB vaccine is cost-saving from the societal perspective. At a willingness to pay threshold of $50,000/QALY, mean net benefit is +49.4 QALYs (S.D. 12.6) from the societal perspective and +3.8 QALYS (S.D. 3.0) from the payer perspective for the "9+9" strategy. Net benefit from the payer perspective is sensitive to the marginal cost of HA/HB vaccine relative to HB vaccine. Similar conclusions may apply in other countries with low incidence and a targeted vaccination policy.

  7. Procedural Portfolio Planning in Plastic Surgery, Part 1: Strategic Changes in Clinical Practice to Increase Physician Revenue, Improve Operative Throughput, and Maintain Patient Satisfaction.

    PubMed

    Hultman, Charles Scott

    2016-06-01

    Portfolio planning in health care represents the strategic prioritization of services that permits an organization to better achieve its goals of margin and mission. Because of recent volatility in the economy, declining reimbursement, and rising costs of providing care, such strategic planning has become increasingly important if physicians want to remain leaders in health care. This project assesses the financial impact of procedural portfolio planning on an academic plastic surgery practice from the physician's perspective. We tracked the top 50 procedures, defined as total charges per CPT code, that were performed in our baseline year, for 6 providers in a stable plastic surgery practice. At the end of the first year, we implemented 3 types of strategic changes: growth of areas with high contribution margin (laser resurfacing of burn scars), curtailment of high-risk procedures with negative contribution margin (panniculectomy in smokers), and improved efficiency of mission-critical services with high resource consumption (free-flap breast reconstruction). During the 2-year study period, we had no turnover in faculty, did not pursue any formal marketing, did not change our surgical fees or billing system, provided care independent of payer mix, and maintained our commitment to indigent care. Outcome measures included procedural charges and revenue, collection rates, work relative value units, operating room times, idle times (room time less case time), receipts/minute in operating room, uncompensated charity care, and patient satisfaction (Press-Gainey scores). Before the study period, annual incremental growth in our practice was 1% to 2%, in terms of charges and receipts. After implementation of the portfolio planning project, the financial position of our division improved significantly, with patient satisfaction rates increasing from 85.5% to 94.1% and charity care remaining constant at US $400,000 per year. Encounters, work relative value units, charges, and receipts all increased by 16% to 27%, with receipts/minute increasing from US $5.60 per minute to US $7.28 per minute. Interestingly, but not surprisingly, highest margin cases did not correspond with highest volume or highest revenue cases; portfolio analysis helped us to align these parameters, without sacrificing patient satisfaction or commitment to indigent care. The highest receipt/minute procedure was laser ablation of vascular lesions (US $23.87), whereas one of the lowest receipt/minute cases was muscle free flap (US $3.07). Procedural portfolio analysis is a powerful tool that can guide strategy and positively impact the financial position and clinical value of the services provided by an academic plastic surgery practice. Identifying high margin procedures allows the surgeon to focus marketing efforts, target areas of future growth, and optimize the blend of margin and mission.

  8. The Knowledge Base for Achieving the Sustainable Development Goal Targets on Water Supply, Sanitation and Hygiene.

    PubMed

    Hutton, Guy; Chase, Claire

    2016-05-27

    Safe drinking water, sanitation, and hygiene (WASH) are fundamental to an improved standard of living. Globally, 91% of households used improved drinking water sources in 2015, while for improved sanitation it is 68%. Wealth disparities are stark, with rural populations, slum dwellers and marginalized groups lagging significantly behind. Service coverage is significantly lower when considering the new water and sanitation targets under the sustainable development goals (SDGs) which aspire to a higher standard of 'safely managed' water and sanitation. Lack of access to WASH can have an economic impact as much as 7% of Gross Domestic Product, not including the social and environmental consequences. Research points to significant health and socio-economic consequences of poor nutritional status, child growth and school performance caused by inadequate WASH. Groundwater over-extraction and pollution of surface water bodies have serious impacts on water resource availability and biodiversity, while climate change exacerbates the health risks of water insecurity. A significant literature documents the beneficial impacts of WASH interventions, and a growing number of impact evaluation studies assess how interventions are optimally financed, implemented and sustained. Many innovations in behavior change and service delivery offer potential for scaling up services to meet the SDGs.

  9. In vivo assessment of high-grade glioma biochemistry using microdialysis: a study of energy-related molecules, growth factors and cytokines.

    PubMed

    Marcus, Hani J; Carpenter, Keri L H; Price, Stephen J; Hutchinson, Peter J

    2010-03-01

    Microdialysis enables measurement of the chemistry of the cerebral extracellular fluid. This study's objective was to utilise microdialysis to monitor levels of glucose, lactate, pyruvate, glutamate and glycerol in patients following surgery for intrinsic brain tumours, and to assess the concentration of growth factors, cytokines and other proteins involved in the pathogenesis of high-grade gliomas in vivo. Eight patients with suspected high-grade gliomas were studied. Seven of these underwent resection with one microdialysis catheter placed at the tumour resection margin and, in six of these seven cases, a second microdialysis catheter in macroscopically normal peritumour tissue. The remaining glioma patient had an image-guided biopsy with a single catheter inserted stereotactically at the tumour margin. Histology demonstrated WHO IV glioblastoma in five cases, WHO III anaplastic astrocytoma in two cases, and one cerebral lymphoma. In the high-grade gliomas (WHO IV and III), tumour margin microdialysates consistently showed significantly lower glucose, higher lactate/pyruvate (L/P) ratio, higher glutamate and higher glycerol, relative to peritumour microdialysates (P < 0.05). These results indicate that malignant glioma margin tissue is metabolically extremely active. There was great variability in the microdialysate concentrations of growth factors (TGFalpha, EGF, VEGF), cytokines (IL-1alpha, IL-1beta, IL-1ra, IL-6, IL-8), matrix metalloproteinases (MMP-2, MMP-9) and their endogenous inhibitors (TIMP-1, TIMP-2). Notably, microdialysates from the glioma resection margin demonstrated significantly higher IL-8 concentration and higher MMP-2/TIMP-1 ratio when compared to peritumour microdialysates (P < 0.05), suggesting an environment favouring invasion and angiogenesis at the tumour margin. Microdialysis is a promising technique to study in vivo glioma metabolism, and may assist in the development of new therapies.

  10. Positive margins prediction in breast cancer conservative surgery: Assessment of a preoperative web-based nomogram.

    PubMed

    Alves-Ribeiro, Lídia; Osório, Fernando; Amendoeira, Isabel; Fougo, José Luís

    2016-08-01

    Margin status of the surgical specimen has been shown to be a prognostic and risk factor for local recurrence in breast cancer surgery. It has been studied as a topic of intervention to diminish reoperation rates and reduce the probability of local recurrence in breast conservative surgery (BCS). This study aims to validate the Dutch BreastConservation! nomogram, created by Pleijhus et al., which predicts preoperative probability of positive margins in BCS. Patients with diagnosis of breast cancer stages cT1-2, who underwent BCS at the Breast Center of São João University Hospital (BC-CHSJ) in 2013-2014, were included. Association and correlation were evaluated for clinical, radiological, pathological and surgical variables. Multivariable logistic regression and ROC curves were used to assess nomogram parameters and discrimination. In our series of 253 patients, no associations were found between margin status and other studied variables (such as age or family history of breast cancer), except for weight (p-value = 0.045) and volume (p-value = 0.012) of the surgical specimen. Regarding the nomogram, a statistically significant association was shown between cN1 status and positive margins (p-value = 0.014). No differences were registered between the scores of patients with positive versus negative margins. Discrimination analysis showed an AUC of 0.474 for the basic and 0.508 for the expanded models. We cannot assume its external validation or its applicability to our cohort. Further studies are needed to determine the validity of this nomogram and achieve a broader view of currently available tools. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Ultrasound and anatomical assessment of the infraspinatus tendon through anterosuperolateral approach.

    PubMed

    Michelin, Paul; Kasprzak, Kevin; Dacher, Jean Nicolas; Lefebvre, Valentin; Duparc, Fabrice

    2015-08-01

    In the literature, shoulder ultrasound (US) protocols rely on the widely accepted anatomical concept of the infraspinatus tendon (IST) running parallel and posterior to the supraspinatus tendon (SST). To assess the IST, authors currently recommend placing the transducer posteroinferior to the acromion; however the examination of the anterosuperior part of the IST remains problematic. The aim of our study was to apply recent anatomical knowledge to propose a simple protocol to assess the IST over its entire width including its anterosuperior margin. Six non-diseased shoulders from four cadavers were assessed in hyperextended internal rotation (HIR) position with US anterosuperolateral approach followed by dissection. Twelve healthy volunteers underwent similar US examination of the shoulder. The IST is a thin, wide, strap-like tendon. The HIR position exposed the largest area of IST beyond the acromion; combined anterosuperolateral US approach enabled imaging of the IST over its entire width with transverse and longitudinal views. The anterosuperior margin of the IST was distinguishable from the SST. The anterosuperolateral US approach in HIR position enables an accurate assessment of the IST including the transverse plane. The limit between the SST and IST appears more clearly. • The hyperextended internal rotation of the shoulder brings the infraspinatus tendon forward. • The infraspinatus tendon is visible with anterosuperolateral ultrasound approach. • The anterosuperior margin of the infraspinatus tendon is visible with this technique.

  12. Predictive Validity of the HKT-R Risk Assessment Tool: Two and 5-Year Violent Recidivism in a Nationwide Sample of Dutch Forensic Psychiatric Patients.

    PubMed

    Bogaerts, Stefan; Spreen, Marinus; Ter Horst, Paul; Gerlsma, Coby

    2018-06-01

    This study has examined the predictive validity of the Historical Clinical Future [ Historisch Klinisch Toekomst] Revised risk assessment scheme in a cohort of 347 forensic psychiatric patients, which were discharged between 2004 and 2008 from any of 12 highly secure forensic centers in the Netherlands. Predictive validity was measured 2 and 5 years after release. Official reconviction data obtained from the Dutch Ministry of Security and Justice were used as outcome measures. Violent reoffending within 2 and 5 years after discharge was assessed. With regard to violent reoffending, results indicated that the predictive validity of the Historical domain was modest for 2 (area under the curve [AUC] = .75) and 5 (AUC = .74) years. The predictive validity of the Clinical domain was marginal for 2 (admission: AUC = .62; discharge: AUC = .63) and 5 (admission: AUC = .69; discharge: AUC = .62) years after release. The predictive validity of the Future domain was modest (AUC = .71) for 2 years and low for 5 (AUC = .58) years. The total score of the instrument was modest for 2 years (AUC = .78) and marginal for 5 (AUC = .68) years. Finally, the Final Risk Judgment was modest for 2 years (AUC = .78) and marginal for 5 (AUC = .63) years time at risk. It is concluded that this risk assessment instrument appears to be a satisfactory instrument for risk assessment.

  13. Marginal and internal fit of CAD-CAM-fabricated composite resin and ceramic crowns scanned by 2 intraoral cameras.

    PubMed

    de Paula Silveira, Alessandra C; Chaves, Sacha B; Hilgert, Leandro A; Ribeiro, Ana Paula D

    2017-03-01

    The precision of fit of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) complete crowns is affected by digital impression and restorative material. The purpose of this in vitro study was to evaluate by microcomputed tomography (μCT) the marginal and internal adaptation of composite resin and ceramic complete crowns fabricated with 2 different intraoral cameras and 2 restorative materials. Ten extracted human third molars received crown preparations. For each prepared molar, 2 digital impressions were made with different intraoral cameras of the CEREC system, Bluecam and Omnicam. Four groups were formed: LB (Lava Ultimate+Bluecam), EB (Emax+Bluecam), LO (Lava Ultimate+Omnicam), and EO (Emax+Omnicam). Before measuring the precision of fit, all crowns were stabilized with a silicone material. Each unit (crown + prepared tooth) was imaged with μCT, and marginal and internal discrepancies were analyzed. For the 2D analysis, 120 measurements were made of each crown for marginal adaptation, 20 for marginal discrepancy (MD), and 20 for absolute marginal discrepancy (AMD); and for internal adaptation, 40 for axial space (AS) and 40 for occlusal space (OS). After reconstructing the 3D images, the average internal space (AIS) was calculated by dividing the total volume of the internal space by the contact surface. Data were analyzed with 2-way ANOVA and quantile regression. Regarding marginal adaptation, no significant differences were observed among groups. For internal adaptation measured in the 2D evaluation, a significant difference was observed between LO and EO for the AS variable (Mann-Whitney test; P<.008). In assessment of AIS by the 3D reconstruction, LB presented significantly lower values than the other groups (Tukey post hoc test; P<.05). Bluecam presented lower values of AIS than Omnicam, and composite resin crowns showed less discrepancy than did ceramic crowns. The marginal adaptations assessed in all groups showed values within the clinically accepted range. Moreover, the composite resin blocks associated with the Bluecam intraoral camera demonstrated the best results for AIS compared with those of the other groups. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  14. Peri-operative imaging of cancer margins with reflectance confocal microscopy during Mohs micrographic surgery: feasibility of a video-mosaicing algorithm

    NASA Astrophysics Data System (ADS)

    Flores, Eileen; Yelamos, Oriol; Cordova, Miguel; Kose, Kivanc; Phillips, William; Rossi, Anthony; Nehal, Kishwer; Rajadhyaksha, Milind

    2017-02-01

    Reflectance confocal microscopy (RCM) imaging shows promise for guiding surgical treatment of skin cancers. Recent technological advancements such as the introduction of the handheld version of the reflectance confocal microscope, video acquisition and video-mosaicing have improved RCM as an emerging tool to evaluate cancer margins during routine surgical skin procedures such as Mohs micrographic surgery (MMS). Detection of residual non-melanoma skin cancer (NMSC) tumor during MMS is feasible, as demonstrated by the introduction of real-time perioperative imaging on patients in the surgical setting. Our study is currently testing the feasibility of a new mosaicing algorithm for perioperative RCM imaging of NMSC cancer margins on patients during MMS. We report progress toward imaging and image analysis on forty-five patients, who presented for MMS at the MSKCC Dermatology service. The first 10 patients were used as a training set to establish an RCM imaging algorithm, which was implemented on the remaining test set of 35 patients. RCM imaging, using 35% AlCl3 for nuclear contrast, was performed pre- and intra-operatively with the Vivascope 3000 (Caliber ID). Imaging was performed in quadrants in the wound, to simulate the Mohs surgeon's examination of pathology. Videos were taken at the epidermal and deep dermal margins. Our Mohs surgeons assessed all videos and video-mosaics for quality and correlation to histology. Overall, our RCM video-mosaicing algorithm is feasible. RCM videos and video-mosaics of the epidermal and dermal margins were found to be of clinically acceptable quality. Assessment of cancer margins was affected by type of NMSC, size and location. Among the test set of 35 patients, 83% showed acceptable imaging quality, resolution and contrast. Visualization of nuclear and cellular morphology of residual BCC/SCC tumor and normal skin features could be detected in the peripheral and deep dermal margins. We observed correlation between the RCM videos/video-mosaics and the corresponding histology in 32 lesions. Peri-operative RCM imaging shows promise for improved and faster detection of cancer margins and guiding MMS in the surgical setting.

  15. Comparative analysis of intraoral radiographs with variation of tube angulation to detect insufficient crown margins.

    PubMed

    Sailer, Benjamin F; Geibel, Margrit-Ann

    2013-01-01

    Variations in angulation of the x-ray tube affect the appearance of insufficient approximal crown margins on intraoral radiographs. This study examines the impact of such angular variation on the assessment of digital radiographs using three different X-ray tubes--Heliodent DS (Sirona), Gendex Expert DC (KaVo Dental) and Focus (KaVo Dental)--as well as the Gendex Visualix eHD CCD sensor (KaVo Dental). The test specimens, crowned teeth 46 from two mandibles provided by the Institute of Anatomy and Cell Biology, were examined with each tube. The results indicate great differences in the angles indicative of insufficient crown margins on X-ray images. Because of beam divergence and the crown marginal gap, the length and width of which frequently varies, it is difficult to infer any optimum angle from the data. This leads to the conclusion that at present, it is not possible to establish ideal angles for visualization of insufficient approximal crown margins.

  16. Syndemic theory and HIV-related risk among young transgender women: the role of multiple, co-occurring health problems and social marginalization.

    PubMed

    Brennan, Julia; Kuhns, Lisa M; Johnson, Amy K; Belzer, Marvin; Wilson, Erin C; Garofalo, Robert

    2012-09-01

    We assessed whether multiple psychosocial factors are additive in their relationship to sexual risk behavior and self-reported HIV status (i.e., can be characterized as a syndemic) among young transgender women and the relationship of indicators of social marginalization to psychosocial factors. Participants (n = 151) were aged 15 to 24 years and lived in Chicago or Los Angeles. We collected data on psychosocial factors (low self-esteem, polysubstance use, victimization related to transgender identity, and intimate partner violence) and social marginalization indicators (history of commercial sex work, homelessness, and incarceration) through an interviewer-administered survey. Syndemic factors were positively and additively related to sexual risk behavior and self-reported HIV infection. In addition, our syndemic index was significantly related to 2 indicators of social marginalization: a history of sex work and previous incarceration. These findings provide evidence for a syndemic of co-occurring psychosocial and health problems in young transgender women, taking place in a context of social marginalization.

  17. Automatic Identification & Classification of Surgical Margin Status from Pathology Reports Following Prostate Cancer Surgery

    PubMed Central

    D’Avolio, Leonard W.; Litwin, Mark S.; Rogers, Selwyn O.; Bui, Alex A. T.

    2007-01-01

    Prostate cancer removal surgeries that result in tumor found at the surgical margin, otherwise known as a positive surgical margin, have a significantly higher chance of biochemical recurrence and clinical progression. To support clinical outcomes assessment a system was designed to automatically identify, extract, and classify key phrases from pathology reports describing this outcome. Heuristics and boundary detection were used to extract phrases. Phrases were then classified using support vector machines into one of three classes: ‘positive (involved) margins,’ ‘negative (uninvolved) margins,’ and ‘not-applicable or definitive.’ A total of 851 key phrases were extracted from a sample of 782 reports produced between 1996 and 2006 from two major hospitals. Despite differences in reporting style, at least 1 sentence containing a diagnosis was extracted from 780 of the 782 reports (99.74%). Of the 851 sentences extracted, 97.3% contained diagnoses. Overall accuracy of automated classification of extracted sentences into the three categories was 97.18%. PMID:18693818

  18. Hybrid value foraging: How the value of targets shapes human foraging behavior.

    PubMed

    Wolfe, Jeremy M; Cain, Matthew S; Alaoui-Soce, Abla

    2018-04-01

    In hybrid foraging, observers search visual displays for multiple instances of multiple target types. In previous hybrid foraging experiments, although there were multiple types of target, all instances of all targets had the same value. Under such conditions, behavior was well described by the marginal value theorem (MVT). Foragers left the current "patch" for the next patch when the instantaneous rate of collection dropped below their average rate of collection. An observer's specific target selections were shaped by previous target selections. Observers were biased toward picking another instance of the same target. In the present work, observers forage for instances of four target types whose value and prevalence can vary. If value is kept constant and prevalence manipulated, participants consistently show a preference for the most common targets. Patch-leaving behavior follows MVT. When value is manipulated, observers favor more valuable targets, though individual foraging strategies become more diverse, with some observers favoring the most valuable target types very strongly, sometimes moving to the next patch without collecting any of the less valuable targets.

  19. Localized Glacier Deformation Associated with Filling and Draining of a Glacier-Dammed Lake and Implications for Outburst Flood Hydraulics

    NASA Astrophysics Data System (ADS)

    Cunico, M. L.; Walder, J. S.; Fountain, A. G.; Trabant, D. C.

    2001-12-01

    During the summer of 2000, we measured displacements of 22 survey targets on the surface of Kennicott Glacier, Alaska, in the vicinity of Hidden Creek Lake, an ice-dammed lake in a tributary valley that fills and drains annually. Targets were distributed over a domain about equal in width to the lake, from near the glacier/lake margin to a distance of about 1 km from the margin. Targets were surveyed over a 24-day period as the lake filled and then drained. Lake stage was independently monitored. Vertical movement of targets generally fell off with distance d from the lake. As the lake filled, targets with d < 300 to 400 m rose at nearly the same rate as the lake--typically about 0.5 m/d--with a few targets rising slightly faster than the lake. The rate of vertical movement fell off rapidly with distance from the lake: for d = ca. 600 m--roughly twice the local ice thickness--targets moved upward only about 10% as fast as lake stage. Vertical movement of targets with d > ca. 1 km seemed to be uncorrelated with lake stage. The general pattern is consistent with the idea that a wedge of water extended beneath the glacier to a distance of perhaps 300 to 400 m from the visible margin of the lake and exerts buoyant stresses on the ice that were transmitted into the main body of the glacier and caused flexure. This scenario bears some resemblance to tidal deflections of ice shelves or tidewater glaciers. For a given value of lake stage, target elevations were invariably higher as the lake drained than as the lake filled. Moreover, survey targets at a distance of about 400 m or more from the lake continued to rise for some time even after the lake began to drain. The lag time between the beginning of lake drainage and the beginning of target downdrop increased with distance from the lake, with the lag being about 14 hours at a distance of 400 m from the lake. (The lake drained completely in approximately 75 hours.) The likeliest explanations for the departure from reversibility and the existence of the time lag are either (i) a "viscous" response of the glacier to the flexural stresses imposed by the subglacial water wedge, or (ii) movement of water from the lake into temporary storage--a sort of hydraulic jacking. We favor the latter explanation and suggest that as the lake drained, water "backed up" from a main drainage channel into a basal cavity system and perhaps englacial voids as well; the stored water then drained back out as pressure eventually fell in the main channel. Assuming that all the vertical downdrop of the ice is due to the evacuation of water, the total volume of the putative subglacial "wedge" plus the water released from distributed storage is about 7 to 11 million cubic meters, or about 25 to 40% of the volume of the subaerial lake.

  20. Assessing Students in the Margin: Challenges, Strategies, and Techniques

    ERIC Educational Resources Information Center

    Russell, Michael; Kavanaugh, Maureen

    2011-01-01

    The importance of student assessment, particularly for summative purposes, has increased greatly over the past thirty years. At the same time, emphasis on including all students in assessment programs has also increased. Assessment programs, whether they are large-scale, district-based, or teacher developed, have traditionally attempted to assess…

  1. Difference in target definition using three different methods to include respiratory motion in radiotherapy of lung cancer.

    PubMed

    Sloth Møller, Ditte; Knap, Marianne Marquard; Nyeng, Tine Bisballe; Khalil, Azza Ahmed; Holt, Marianne Ingerslev; Kandi, Maria; Hoffmann, Lone

    2017-11-01

    Minimizing the planning target volume (PTV) while ensuring sufficient target coverage during the entire respiratory cycle is essential for free-breathing radiotherapy of lung cancer. Different methods are used to incorporate the respiratory motion into the PTV. Fifteen patients were analyzed. Respiration can be included in the target delineation process creating a respiratory GTV, denoted iGTV. Alternatively, the respiratory amplitude (A) can be measured based on the 4D-CT and A can be incorporated in the margin expansion. The GTV expanded by A yielded GTV + resp, which was compared to iGTV in terms of overlap. Three methods for PTV generation were compared. PTV del (delineated iGTV expanded to CTV plus PTV margin), PTV σ (GTV expanded to CTV and A was included as a random uncertainty in the CTV to PTV margin) and PTV ∑ (GTV expanded to CTV, succeeded by CTV linear expansion by A to CTV + resp, which was finally expanded to PTV ∑ ). Deformation of tumor and lymph nodes during respiration resulted in volume changes between the respiratory phases. The overlap between iGTV and GTV + resp showed that on average 7% of iGTV was outside the GTV + resp implying that GTV + resp did not capture the tumor during the full deformable respiration cycle. A comparison of the PTV volumes showed that PTV σ was smallest and PTV Σ largest for all patients. PTV σ was in mean 14% (31 cm 3 ) smaller than PTV del , while PTV del was 7% (20 cm 3 ) smaller than PTV Σ . PTV σ yields the smallest volumes but does not ensure coverage of tumor during the full respiratory motion due to tumor deformation. Incorporating the respiratory motion in the delineation (PTV del ) takes into account the entire respiratory cycle including deformation, but at the cost, however, of larger treatment volumes. PTV Σ should not be used, since it incorporates the disadvantages of both PTV del and PTV σ .

  2. SU-E-T-318: The Effect of Patient Positioning Errors On Target Coverage and Cochlear Dose in Stereotactic Radiosurgery Treatment of Acoustic Neuromas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dellamonica, D.; Luo, G.; Ding, G.

    Purpose: Setup errors on the order of millimeters may cause under-dosing of targets and significant changes in dose to critical structures especially when planning with tight margins in stereotactic radiosurgery. This study evaluates the effects of these types of patient positioning uncertainties on planning target volume (PTV) coverage and cochlear dose for stereotactic treatments of acoustic neuromas. Methods: Twelve acoustic neuroma patient treatment plans were retrospectively evaluated in Brainlab iPlan RT Dose 4.1.3. All treatment beams were shaped by HDMLC from a Varian TX machine. Seven patients had planning margins of 2mm, five had 1–1.5mm. Six treatment plans were createdmore » for each patient simulating a 1mm setup error in six possible directions: anterior-posterior, lateral, and superiorinferior. The arcs and HDMLC shapes were kept the same for each plan. Change in PTV coverage and mean dose to the cochlea was evaluated for each plan. Results: The average change in PTV coverage for the 72 simulated plans was −1.7% (range: −5 to +1.1%). The largest average change in coverage was observed for shifts in the patient's superior direction (−2.9%). The change in mean cochlear dose was highly dependent upon the direction of the shift. Shifts in the anterior and superior direction resulted in an average increase in dose of 13.5 and 3.8%, respectively, while shifts in the posterior and inferior direction resulted in an average decrease in dose of 17.9 and 10.2%. The average change in dose to the cochlea was 13.9% (range: 1.4 to 48.6%). No difference was observed based on the size of the planning margin. Conclusion: This study indicates that if the positioning uncertainty is kept within 1mm the setup errors may not result in significant under-dosing of the acoustic neuroma target volumes. However, the change in mean cochlear dose is highly dependent upon the direction of the shift.« less

  3. Theory and practice in health communication campaigns: a critical interrogation.

    PubMed

    Dutta-Bergman, Mohan J

    2005-01-01

    In recent reviews of the body of work on health campaigns, communication scholars discussed the importance of reflective thinking about the capacity of campaigns to effect change; this reflective thinking is especially important in the realm of the increasing gaps in society between the health rich and the health poor and the increasing marginalization of the poorer sections of society. This article critically reviews 3 central theories of health communication campaigns that represent the dominant cognitive approach: theory of reasoned action, health belief model, and the extended parallel process model. After articulating the limitations of these theoretical approaches, the article summarizes new directions in theory, methodology, and application of health communication campaigns targeting marginalized populations.

  4. Small-target leak detection for a closed vessel via infrared image sequences

    NASA Astrophysics Data System (ADS)

    Zhao, Ling; Yang, Hongjiu

    2017-03-01

    This paper focus on a leak diagnosis and localization method based on infrared image sequences. Some problems on high probability of false warning and negative affect for marginal information are solved by leak detection. An experimental model is established for leak diagnosis and localization on infrared image sequences. The differential background prediction is presented to eliminate the negative affect of marginal information on test vessel based on a kernel regression method. A pipeline filter based on layering voting is designed to reduce probability of leak point false warning. A synthesize leak diagnosis and localization algorithm is proposed based on infrared image sequences. The effectiveness and potential are shown for developed techniques through experimental results.

  5. Emergence and Utility of Nonspherical Particles in Biomedicine

    PubMed Central

    Fish, Margaret B.; Thompson, Alex J.; Fromen, Catherine A.; Eniola-Adefeso, Omolola

    2016-01-01

    The importance of the size of targeted, spherical drug carriers has been previously explored and reviewed. Particle shape has emerged as an equally important parameter in determining the in vivo journey and efficiency of drug carrier systems. Researchers have invented techniques to better control the geometry of particles of many different materials, which have allowed for exploration of the role of particle geometry in the phases of drug delivery. The important biological processes include clearance by the immune system, trafficking to the target tissue, margination to the endothelial surface, interaction with the target cell, and controlled release of a payload. The review of current literature herein supports that particle shape can be altered to improve a system’s targeting efficiency. Non-spherical particles can harness the potential of targeted drug carriers by enhancing targeted site accumulation while simultaneously decreasing side effects and mitigating some limitations faced by spherical carriers. PMID:27182109

  6. Can BI-RADS features on mammography be used as a surrogate for expensive genomic testing in breast cancer patients?

    NASA Astrophysics Data System (ADS)

    Harowicz, Michael R.; Marks, Jeffrey R.; Marcom, P. Kelly; Mazurowski, Maciej A.

    2017-03-01

    Medical oncologists increasingly rely on expensive genomic analysis to stratify patients for different treatment. The genomic markers are able to divide patients into groups that behave differently in terms of tumor presentation, likelihood of metastatic spread, and response to chemotherapy and radiation therapy. In recent years there has been a rapid increase in the number of genomic tests available, like the Oncotype DX test, which provides the risk of cancer recurrence for a subset of patients. Radiogenomics, a new field that investigates the relationship between imaging phenotypes and genomic characteristics, may offer a less expensive and less invasive imaging surrogate for molecular subtype and Oncotype DX recurrence score (ODRS). This retrospective study analyzes the relationship between Breast Imaging-Reporting and Data System (BI-RADS) features as assessed by radiologists on mammograms with molecular subtype and ODRS. We used data from patients with BI-RADS features (shape or margin) and a genomic feature (subtype or ODRS) for the following cohort: shape vs. subtype (n=69), margin vs. subtype (n=78), shape vs. ODRS (n=20), and margin vs. ODRS (n=18). The association between features was assessed using a Fisher's exact test. Our results show that shape assessed by radiologists according to the BI-RADS lexicon is associated with molecular subtype (p=0.0171), while BI-RADS features of shape and margin were not significantly associated with ODRS (p=0.7839, p=0.6047 respectively).

  7. Controlling marginally detached divertor plasmas

    NASA Astrophysics Data System (ADS)

    Eldon, D.; Kolemen, E.; Barton, J. L.; Briesemeister, A. R.; Humphreys, D. A.; Leonard, A. W.; Maingi, R.; Makowski, M. A.; McLean, A. G.; Moser, A. L.; Stangeby, P. C.

    2017-06-01

    A new control system at DIII-D has stabilized the inter-ELM detached divertor plasma state for H-mode in close proximity to the threshold for reattachment, thus demonstrating the ability to maintain detachment with minimal gas puffing. When the same control system was instead ordered to hold the plasma at the threshold (here defined as T e  =  5 eV near the divertor target plate), the resulting T e profiles separated into two groups with one group consistent with marginal detachment, and the other with marginal attachment. The plasma dithers between the attached and detached states when the control system attempts to hold at the threshold. The control system is upgraded from the one described in Kolemen et al (2015 J. Nucl. Mater. 463 1186) and it handles ELMing plasmas by using real time D α measurements to remove during-ELM slices from real time T e measurements derived from divertor Thomson scattering. The difference between measured and requested inter-ELM T e is passed to a PID (proportional-integral-derivative) controller to determine gas puff commands. While some degree of detachment is essential for the health of ITER’s divertor, more deeply detached plasmas have greater radiative losses and, at the extreme, confinement degradation, making it desirable to limit detachment to the minimum level needed to protect the target plate (Kolemen et al 2015 J. Nucl. Mater. 463 1186). However, the observed bifurcation in plasma conditions at the outer strike point with the ion B   ×  \

  8. In vivo Sonothrombolysis of Ear Marginal Vein of Rabbits Monitored with High-frequency Ultrasound Needle Transducer.

    PubMed

    Chen, Ruimin; Paeng, Dong-Guk; Lam, Kwok Ho; Zhou, Qifa; Shung, K Kirk; Matsuoka, Naoki; Humayun, Mark S

    2013-01-01

    Ultrasound (US) is known to enhance thrombolysis when thrombolytic agents and/or microbubbles are injected into the targeted vessels. In this research, high-intensity US (1 MHz, 7 W/cm 2 , 30 % duty cycle) was applied in vivo to the ear marginal vein of three rabbits which was occluded by either laser photothrombosis or thrombin, right after the injection of 0.3~0.6 cc of microbubbles (13 × 10 8 bubbles/ml of concentration) through the other ear vein without using any thrombolytic agent. To determine the effect of the sonothrombolysis, the blood flow velocity near the occlusion site in the vein was measured by a custom-made 40-MHz US needle transducer and its corresponding Doppler US system. The Doppler spectra show that the blood flow velocity recovered from total occlusion after three 10-minute high-intensity US treatments. Fluorescein angiography was employed to confirm the opening of the vessel occlusion. A control study of three rabbits with only the microbubble injection showed no recovery on the occlusion in 3 hours. The results show that the sonothrombolysis in the rabbit ear marginal vein can be achieved with microbubbles only. The results of cavitation measurements indicate that the mechanism of sonothrombolysis is probably due to the cavitation induced by the microbubbles. Without the need of applying any thrombolytic agent, high-intensity US has high potential for therapies targeting on small blood vessels.

  9. Upper mantle structure at Walvis Ridge from Pn tomography

    NASA Astrophysics Data System (ADS)

    Ryberg, Trond; Braeuer, Benjamin; Weber, Michael

    2017-10-01

    Passive continental margins offer the unique opportunity to study the processes involved in continental extension and break-up. Within the LISPWAL (LIthospheric Structure of the Namibian continental Passive margin at the intersection with the Walvis Ridge from amphibious seismic investigations) project, combined on- and offshore seismic experiments were designed to characterize the Southern African passive margin at the Walvis Ridge in northern Namibia. In addition to extensive analysis of the crustal structures, we carried out seismic investigations targeting the velocity structure of the upper mantle in the landfall region of the Walvis Ridge with the Namibian coast. Upper mantle Pn travel time tomography from controlled source, amphibious seismic data was used to investigate the sub-Moho upper mantle seismic velocity. We succeeded in imaging upper mantle structures potentially associated with continental break-up and/or the Tristan da Cunha hotspot track. We found mostly coast-parallel sub-Moho velocity anomalies, interpreted as structures which were created during Gondwana break-up.

  10. Structural Basis for Modulation of Quality Control Fate in a Marginally Stable Protein.

    PubMed

    Brock, Kelly P; Abraham, Ayelet-chen; Amen, Triana; Kaganovich, Daniel; England, Jeremy L

    2015-07-07

    The human von Hippel-Lindau (VHL) tumor suppressor is a marginally stable protein previously used as a model substrate of eukaryotic refolding and degradation pathways. When expressed in the absence of its cofactors, VHL cannot fold and is quickly degraded by the quality control machinery of the cell. We combined computational methods with in vivo experiments to examine the basis of the misfolding propensity of VHL. By expressing a set of randomly mutated VHL sequences in yeast, we discovered a more stable mutant form. Subsequent modeling suggested the mutation had caused a conformational change affecting cofactor and chaperone interaction, and this hypothesis was then confirmed by additional knockout and overexpression experiments targeting a yeast cofactor homolog. These findings offer a detailed structural basis for the modulation of quality control fate in a model misfolded protein and highlight burial mode modeling as a rapid means to detect functionally important conformational changes in marginally stable globular domains. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Costs of the multimicronutrient supplementation program in Chiclayo, Peru.

    PubMed

    Lechtig, Aarón; Gross, Rainer; Paulini, Javier; de Romaã, Daniel López

    2006-01-01

    There is little information on the cost parameters of weekly multimicronutrient supplementation programs. To assess the cost parameters and cost-effectiveness of a weekly multimicronutrient supplementation program in an urban population of Peru. Data from the Integrated Food Security Program (Programa Integrado de Seguridad Alimentaria [PISA]), which distributed capsules and foodlets to women and adolescent girls and to children under five, were extrapolated to a population of 100,000 inhabitants. The annual cost per community member was US$1.51. The cost-effectiveness ratio was US$0.12 per 1% of prevented anemia per community member. These costs are in the upper margin of iron supplementation alone. They will decrease notably when weekly multimicronutrient supplementation programs are integrated into health packages and participation by women increases. Focusing on micronutrient deficiencies would prevent these problems, and food-distribution programs would be effectively targeted to food-deficient populations.

  12. The One or the Many: Quantified Subjectivity and Aggregated Uniqueness in Qualitative Rehabilitation Research.

    PubMed

    Juritzen, Truls I; Soberg, Helene L; Røe, Cecilie; Saebu, Martin; Engen, Grace; Bliksvaer, Trond; Engebretsen, Eivind

    2017-01-01

    This article aims to identify and critically assess qualitative intervention studies of rehabilitation processes that target young adults. By applying a meta-epistemological approach inspired by the works of Michel Foucault and Julia Kristeva, we examine how the included studies present qualitative knowledge and whether they adhere to their own stated principles of qualitative knowledge. Through their stated aims and theoretical framing, the articles draw attention to individual processes of meaning making. Nonetheless, we find that the articles to a great extent emphasize frequencies of the qualitative data they present. Individual processes and experiences are subject to subdivisions and categorization and transformed into manageable objects of knowledge. In conclusion, these studies, with one important exception, contribute to self-marginalization of the knowledge they themselves promote: They undermine the uniqueness of the qualitative knowledge they proclaim by focusing on frequency and the general patterns and categories encompassing the unique. © The Author(s) 2016.

  13. External Validity of the New York University Caregiver Intervention: Key Caregiver Outcomes Across Multiple Demonstration Projects.

    PubMed

    Fauth, Elizabeth B; Jackson, Mark A; Walberg, Donna K; Lee, Nancy E; Easom, Leisa R; Alston, Gayle; Ramos, Angel; Felten, Kristen; LaRue, Asenath; Mittelman, Mary

    2017-06-01

    The Administration on Aging funded six New York University Caregiver Intervention (NYUCI) demonstration projects, a counseling/support intervention targeting dementia caregivers and families. Three sites (Georgia, Utah, Wisconsin) pooled data to inform external validity in nonresearch settings. This study (a) assesses collective changes over time, and (b) compares outcomes across sites on caregiver burden, depressive symptoms, satisfaction with social support, family conflict, and quality of life. Data included baseline/preintervention ( N = 294) and follow-up visits (approximately 4, 8, 12 months). Linear mixed models showed that social support satisfaction increased ( p < .05) and family conflict decreased ( p < .05; Cohen's d = 0.49 and 0.35, respectively). Marginally significant findings emerged for quality of life increases ( p = .05) and burden decreases ( p < .10). Depressive symptoms remained stable. Slopes did not differ much by site. NYUCI demonstrated external validity in nonresearch settings across diverse caregiver samples.

  14. Micro-insurance in Bangladesh: Risk Protection for the Poor?

    PubMed Central

    2009-01-01

    Health services and modern medicines are out of reach for over one billion people globally. Micro-insurance for health is one method to address unmet health needs. This case study used a social exclusion perspective to assess the health and poverty impact of micro-insurance for health in Bangladesh and contrasts this with several micro-insurance systems for health offered in India. Micro-insurance for health in Bangladesh targeted towards the poor and the ultra-poor provides basic healthcare at an affordable rate whereas the Indian micro-insurance schemes for health have been implemented across larger populations and include high-cost and low-frequency events. Results of analysis of the existing literature showed that micro-insurance for health as currently offered in Bangladesh increased access to, and use of, basic health services among excluded populations but did not reduce the likelihood that essential health-related costs would be a catastrophic expense for a marginalized household. PMID:19761089

  15. Influence of Different Implant Geometry in Clinical Longevity and Maintenance of Marginal Bone: A Systematic Review.

    PubMed

    Lovatto, Sabrina Telles; Bassani, Rafaela; Sarkis-Onofre, Rafael; Dos Santos, Mateus Bertolini Fernandes

    2018-03-26

    To assess, through a systematic review, the influence of different implant geometries on clinical longevity and maintenance of marginal bone tissue. An electronic search was conducted in MEDLINE, Scopus, and Web of Science databases, limited to studies written in English from 1996 to 2017 using specific search strategies. Only randomized controlled trials (RCTs) that compared dental implants and their geometries were included. Two reviewers independently selected studies, extracted data, and assessed the risk of bias of included studies. From the 4006 references identified by the search, 24 were considered eligible for full-text analysis, after which 10 studies were included in this review. A similar behavior of marginal bone loss between tapered and cylindrical geometries was observed; however, implants that had micro-threads in the neck presented a slight decrease of marginal bone loss compared to implants with straight or smooth neck. Success and survival rates were high, with cylindrical implants presenting higher success and survival rates than tapered ones. Implant geometry seems to have little influence on marginal bone loss (MBL) and survival and success rates after 1 year of implant placement; however, the evidence in this systematic review was classified as very low due to limitations such as study design, sample size, and publication bias. Thus, more well-designed RCTs should be conducted to provide evidence regarding the influence of implant geometry on MBL and survival and success rates after 1 year of implant placement. © 2018 by the American College of Prosthodontists.

  16. Influences of temperature and environmental variables on the distribution of bull trout within streams at the southern margin of its range

    Treesearch

    J. Dunham; B. Rieman; G. Chandler

    2003-01-01

    The bull trout Salvelinus confluentus is believed to be among the most thermally sensitive species in coldwater habitats in western North America. We conducted a comprehensive field assessment of thermal habitat associations throughout the southern margin of the species' range. We developed models of thermal habitat associations using two data sets representing a...

  17. Incidence and location of positive surgical margin among open, laparoscopic and robot-assisted radical prostatectomy in prostate cancer patients: a single institutional analysis.

    PubMed

    Koizumi, Atsushi; Narita, Shintaro; Nara, Taketoshi; Takayama, Koichiro; Kanda, Sohei; Numakura, Kazuyuki; Tsuruta, Hiroshi; Maeno, Atsushi; Huang, Mingguo; Saito, Mitsuru; Inoue, Takamitsu; Tsuchiya, Norihiko; Satoh, Shigeru; Nanjo, Hiroshi; Habuchi, Tomonori

    2018-06-19

    To evaluate the positive surgical margin rates and locations in radical prostatectomy among three surgical approaches, including open radical prostatectomy, laparoscopic radical prostatectomy and robot-assisted radical prostatectomy. We retrospectively reviewed clinical outcomes at our institution of 450 patients who received radical prostatectomy. Multiple surgeons were involved in the three approaches, and a single pathologist conducted the histopathological diagnoses. Positive surgical margin rates and locations among the three approaches were statistically assessed, and the risk factors of positive surgical margin were analyzed. This study included 127, 136 and 187 patients in the open radical prostatectomy, laparoscopic radical prostatectomy and robot-assisted radical prostatectomy groups, respectively. The positive surgical margin rates were 27.6% (open radical prostatectomy), 18.4% (laparoscopic radical prostatectomy) and 13.4% (robot-assisted radical prostatectomy). In propensity score-matched analyses, the positive surgical margin rate in the robot-assisted radical prostatectomy was significantly lower than that in the open radical prostatectomy, whereas there was no significant difference in the positive surgical margin rates between robot-assisted radical prostatectomy and laparoscopic radical prostatectomy. In the multivariable analysis, PSA level at diagnosis and surgical approach (open radical prostatectomy vs robot-assisted radical prostatectomy) were independent risk factors for positive surgical margin. The apex was the most common location of positive surgical margin in the open radical prostatectomy and laparoscopic radical prostatectomy groups, whereas the bladder neck was the most common location in the robot-assisted radical prostatectomy group. The significant difference of positive surgical margin locations continued after the propensity score adjustment. Robot-assisted radical prostatectomy may potentially achieve the lowest positive surgical margin rate among three surgical approaches. The bladder neck was the most common location of positive surgical margin in robot-assisted radical prostatectomy and apex in open radical prostatectomy and laparoscopic radical prostatectomy. Although robot-assisted radical prostatectomy may contribute to the reduction of positive surgical margin, dissection of the bladder neck requires careful attention to avoid positive surgical margins.

  18. An Analysis of the Extent of Social Inclusion and Equity Consideration in Malawi’s National HIV and AIDS Policy Review Process

    PubMed Central

    Chinyama, Mathews Junior; MacLachlan, Malcolm; McVeigh, Joanne; Huss, Tessy; Gawamadzi, Sylvester

    2018-01-01

    Background: Equity and social inclusion for vulnerable groups in policy development processes and resulting documents remain a challenge globally. Most often, the marginalization of vulnerable groups is overlooked in both the planning and practice of health service delivery. Such marginalization may occur because authorities deem the targeting of those who already have better access to healthcare a cheaper and easier way to achieve short-term health gains. The Government of Malawi wishes to achieve an equitable and inclusive HIV and AIDS Policy. The aim of this study is to assess the extent to which the Malawi Policy review process addressed regional and international health priorities of equity and social inclusion for vulnerable groups in the policy content and policy revision process. Methods: This research design comprised two phases. First, the content of the Malawi HIV and AIDS Policy was assessed using EquiFrame regarding its coverage of 21 Core Concepts of human rights and inclusion of 12 Vulnerable Groups. Second, the engagement of vulnerable groups in the policy process was assessed using the EquIPP matrix. For the latter, 10 interviews were conducted with a purposive sample of representatives of public sector, civil society organizations and development partners who participated in the policy revision process. Data was also collected from documented information of the policy processes. Results: Our analyses indicated that the Malawi HIV and AIDS Policy had a relatively high coverage of Core Concepts of human rights and Vulnerable Groups; although with some notable omissions. The analyses also found that reasonable steps were taken to engage and promote participation of vulnerable groups in the planning, development, implementation, monitoring and evaluation processes of the HIV and AIDS Policy, although again, with some notable exceptions. This is the first study to use both EquiFrame and EquIPP as complimentary tools to assess the content and process of policy. Conclusion: While the findings indicate inclusive processes, commitment to Core Concepts of human rights and inclusion of Vulnerable Groups in relation to the Malawi HIV and AIDS Policy, the results also point to areas in which social inclusion and equity could be further strengthened. PMID:29626397

  19. Time-lagged response of carabid species richness and composition to past management practices and landscape context of semi-natural field margins.

    PubMed

    Alignier, Audrey; Aviron, Stéphanie

    2017-12-15

    Field margins are key features for the maintenance of biodiversity and associated ecosystem services in agricultural landscapes. Little is known about the effects of management practices of old semi-natural field margins, and their historical dimension regarding past management practices and landscape context is rarely considered. In this paper, the relative influence of recent and past management practices and landscape context (during the last five years) were assessed on the local biodiversity (species richness and composition) of carabid assemblages of field margins in agricultural landscapes of northwestern France. The results showed that recent patterns of carabid species richness and composition were best explained by management practices and landscape context measured four or five years ago. It suggests the existence of a time lag in the response of carabid assemblages to past environmental conditions of field margins. The relative contribution of past management practices and past landscape context varied depending on the spatial scale at which landscape context was taken into account. Carabid species richness was higher in grazed or sprayed field margins probably due to increased heterogeneity in habitat conditions. Field margins surrounded by grasslands and crops harbored species associated with open habitats whilst forest species dominated field margins surrounded by woodland. Landscape effect was higher at fine spatial scale, within 50 m around field margins. The present study highlights the importance of considering time-lagged responses of biodiversity when managing environment. It also suggests that old semi-natural field margins should not be considered as undisturbed habitats but more as management units being part of farming activities in agricultural landscapes, as for arable fields. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Interleukins in gingival crevicular fluid in patients with definitive full-coverage restorations.

    PubMed

    Chang, Kai-Chiao J; Wheater, Michelle A; Cabanilla Jacobs, Levyee; Litonjua, Luis A

    2014-04-01

    The objective of this study was to determine interleukin (IL)-1α and IL-8 levels in the gingival crevicular fluid (GCF) of patients with different levels of crown margin placements. Samples of GCF were obtained from 12 study participants with definitive full-coverage restorations with supragingival or equigingival crown margin placements. The periodontal status of the volunteers ranged from healthy to generalized severe periodontitis. Pocket depth and bleeding on probing were assessed at the clinical examination, and interleukin concentrations were determined by enzyme-linked immunosorbent assay (ELISA). Analysis of variance (ANOVA) was used to statistically compare interleukin concentrations between the control, supragingival, and equigingival GCF samples. Compared to controls (60.4 ± 8.9 pg/mL), the average IL-1α concentration in the GCF samples surrounding the supragingival margins was 53.8 ± 9.7 pg/mL and was 110.5 ± 23.3 pg/mL in the equigingival margins. Compared to controls (59.0 ± 14.1 pg/mL), the average IL-8 concentration in the supragingival margins was 46.9 ± 9.7 pg/mL and was 131.4 ± 27.5 pg/mL in the equigingival margins. The trend of higher levels of interleukins in GCF corresponding to equigingival margins was consistent, as was the trend of lower concentrations in supragingival margins compared to the controls; however, statistical significance was not achieved because of the wide biological variation within and between patients. In conclusion, differences in GCF IL-1α and IL-8 concentrations were observed when comparing fixed crown restorations with equigingival and supragingival margins. Gingival inflammation may be dependent on the periodontal condition in addition to restoration or margin placement.

  1. Effect of different breathing patterns in the same patient on stereotactic ablative body radiotherapy dosimetry for primary renal cell carcinoma: A case study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pham, Daniel, E-mail: Daniel.Pham@petermac.org; Kron, Tomas; Foroudi, Farshad

    2013-10-01

    Stereotactic ablative body radiotherapy (SABR) for primary renal cell carcinoma (RCC) targets requires motion management strategies to verify dose delivery. This case study highlights the effect of a change in patient breathing amplitude on the dosimetry to organs at risk and target structures. A 73-year-old male patient was planned for receiving 26 Gy of radiation in 1 fraction of SABR for a left primary RCC. The patient was simulated with four-dimensional computed tomography (4DCT) and the tumor internal target volume (ITV) was delineated using the 4DCT maximum intensity projection. However, the initially planned treatment was abandoned at the radiation oncologist'smore » discretion after pretreatment cone-beam CT (CBCT) motion verification identified a greater than 50% reduction in superior to inferior diaphragm motion as compared with the planning 4DCT. This patient was resimulated with respiratory coaching instructions. To assess the effect of the change in breathing on the dosimetry to the target, each plan was recalculated on the data set representing the change in breathing condition. A change from smaller to larger breathing showed a 46% loss in planning target volume (PTV) coverage, whereas a change from larger breathing to smaller breathing resulted in an 8% decrease in PTV coverage. ITV coverage was similarly reduced by 8% in both scenarios. This case study highlights the importance of tools to verify breathing motion prior to treatment delivery. 4D image guided radiation therapy verification strategies should focus on not only verifying ITV margin coverage but also the effect on the surrounding organs at risk.« less

  2. Poster — Thur Eve — 32: Stereotactic Body Radiation Therapy for Peripheral Lung Lesion: Treatment Planning and Quality Assurance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wan, Shuying; Oliver, Michael; Wang, Xiaofang

    2014-08-15

    Stereotactic body radiation therapy (SBRT), due to its high precision for target localizing, has become widely used to treat tumours at various locations, including the lungs. Lung SBRT program was started at our institution a year ago. Eighteen patients with peripheral lesions up to 3 cm diameter have been treated with 48 Gy in 4 fractions. Based on four-dimensional computed tomography (4DCT) simulation, internal target volume (ITV) was delineated to encompass the respiratory motion of the lesion. A margin of 5 mm was then added to create the planning target volume (PTV) for setup uncertainties. There was no expansion frommore » gross tumour volume (GTV) to clinical target volume (CTV). Pinnacle 9.6 was used as the primary treatment planning system. Volumetric modulated arc therapy (VMAT) technique, with one or two coplanar arcs, generally worked well. For quality assurance (QA), each plan was exported to Eclipse 10 and dose calculation was repeated. Dose volume histograms (DVHs) of the targets and organs at risk (OARs) were then compared between the two treatment planning systems. Winston-Lutz tests were carried out as routine machine QA. Patient-specific QA included ArcCheck measurement with an insert, where an ionization chamber was placed at the centre to measure dose at the isocenter. For the first several patients, and subsequently for the plans with extremely strong modulation, Gafchromic film dosimetry was also employed. For each patient, a mock setup was scheduled prior to treatments. Daily pre- and post-CBCT were acquired for setup and assessment of intra-fractional motion, respectively.« less

  3. Program budgeting and marginal analysis: a case study in chronic airflow limitation.

    PubMed

    Crockett, A; Cranston, J; Moss, J; Scown, P; Mooney, G; Alpers, J

    1999-01-01

    Program budgeting and marginal analysis is a method of priority-setting in health care. This article describes how this method was applied to the management of a disease-specific group, chronic airflow limitation. A sub-program flow chart clarified the major cost drivers. After assessment of the technical efficiency of the sub-programs and careful and detailed analysis, incremental and decremental wish lists of activities were established. Program budgeting and marginal analysis provides a framework for rational resource allocation. The nurturing of a vigorous program management group, with members representing all participants in the process (including patients/consumers), is the key to a successful outcome.

  4. 12 CFR 8.2 - Semiannual assessment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... system (which rates risk management, operational controls, compliance, and asset quality) at its most... follows: If the bank's total assets (consolidated domestic and foreign subsidiaries) are: Over— But not.... The excess is assessed at the marginal rate shown in Column D. (3) The total semiannual assessment is...

  5. Cultures of Play during Middle Childhood: Interpretive Perspectives from Two Distinct Marginalized Communities

    ERIC Educational Resources Information Center

    Guest, Andrew M.

    2013-01-01

    This article offers interpretive perspectives on play as a cultural activity during middle childhood by contrasting two communities targeted for aid by external sport and play programs: a Chicago public housing community and a community of Angolan refugee camps. Ethnographic anecdotes, along with some survey results, demonstrate that aside from…

  6. Analytical steady-state solutions for water-limited cropping systems using saline irrigation water

    USDA-ARS?s Scientific Manuscript database

    Due to the diminishing availability of good quality water for irrigation, it is increasingly important that irrigation and salinity management tools be able to target submaximal crop yields and support the use of marginal quality waters. In this work, we present a steady-state irrigated systems mod...

  7. Moving the Lab into the Field: The Making of Pathologized (Non)Citizens in US Science Education

    ERIC Educational Resources Information Center

    Kirchgasler, Kathryn L.

    2018-01-01

    This article examines how notions of health and citizenship have become entangled in US science education reforms targeting particular populations. Current science education policy assumes that marginalized groups have been historically ignored, and that new research is required to "make diversity visible" in order to adapt instruction…

  8. Appreciative Attitudes toward Jews among Non-Jewish US College Students

    ERIC Educational Resources Information Center

    Mayhew, Matthew J.; Bowman, Nicholas A.; Rockenbach, Alyssa N.; Selznick, Benjamin; Riggers-Piehll, Tiffani

    2018-01-01

    The purpose of this study was to examine appreciative attitudes toward Jews--a historically marginalized and targeted worldview identity group in the context of American higher education--among non-Jewish undergraduates. Drawing from a sample of 13,489 students across 52 institutions and using a multilevel modeling approach, we found that…

  9. Engineering analysis division internal note. OFT-1 margin assessment. [results of analysis to determine space shuttle subsystem margins for orbital flight test

    NASA Technical Reports Server (NTRS)

    Austin, L. D., Jr.

    1977-01-01

    The results are documented of an analysis conducted to determine space shuttle vehicle (SSV) subsystem margins for the reference flight profile for the first orbital flight test (OFT-1). In general, the results show increased margins for the OFT-1 indicators when compared to Mission 3A resutls. The inclusion of element and wing aerodynamic variations on OFT-1, in combination with winds and systems dispersions, resulted in the forward Z (FTO1) attach load indicator exceeding specified limits. The inboard and outboard elevon hinge moment margins (9 percent and 3 percent, respectively) on OFT-1 reflect values consistent with the load relief requirements dictated by elevon hinge moment variations. All other structural load indicators for OFT-1 had margins in excess of 10 percent. The SSV first stage stagnation heating indicators for OFT-1 were about 45 percent less than for Mission 3A. The hydraulic systems demands for both missions were essentially the same. The results also show OFT-1 performance requirements from the consideration of winds and dispersions to be approximately 3,300 lbs greater than Mission 3A.

  10. Sci-Thur PM – Brachytherapy 03: Identifying the impact of seroma visualization on permanent breast seed implant brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morton, Daniel; Batchelar, Deidre; Hilts, Michelle

    Purpose: Uncertainties in target identification can reduce treatment accuracy in permanent breast seed implant (PBSI) brachytherapy. This study evaluates the relationship between seroma visualization and seed placement accuracy. Methods: Spatially co-registered CT and 3D ultrasound (US) images were acquired for 10 patients receiving PBSI. Seromas were retrospectively contoured independently by 3 radiation oncologists on both CT and US and respective consensus volumes were defined, CTV{sub CT} and CTV{sub US}. The seroma clarity and inter-user conformity index (CI), as well as inter-modality CI, volume, and positional differences were evaluated. Correlations with seed placement accuracy were then assessed. CTVs were expanded bymore » 1.25cm to create PTV{sub CT} and PTV{sub US} and evaluate the conformity with PTV{sub Clinical} (CTV{sub Clinical}+1.25cm) used in treatment planning. The change in PTV coincidence by expanding PTV{sub Clinical} by 0.25cm was determined. Results: CTV{sub US} were a mean 68 ± 12% smaller than CTV{sub CT} and generally had improved clarity and inter-user conformity. No correlations between seed displacement and CTV{sub US}-CTV{sub CT} positional difference or CI were observed. Greater seed displacements were associated with larger CTV{sub US}-CTV{sub CT} volume differences (r=−0.65) and inter-user CT CI (r=−0.74). A median (range) 88% (71–99%) of PTV{sub CT} and 83% (69–100%) of PTV{sub US} were contained within PTV{sub Clinical}. Expanding treatment margins to 1.5cm increased coincidence to 98% (86–100%) and 94% (82–100%), respectively. Conclusions: Differences in seroma visualization impacts seed displacement in PBSI. Reducing dependence on CT by incorporating 3DUS into target identification, or expanding CT-based treatment margins to 1.5cm may reduce or mitigate uncertainties related to seroma visualization.« less

  11. Impact of target area selection in 125 Iodine seed brachytherapy on locoregional recurrence in patients with non-small cell lung cancer.

    PubMed

    Yan, Wei-Liang; Lv, Jin-Shuang; Guan, Zhi-Yu; Wang, Li-Yang; Yang, Jing-Kui; Liang, Ji-Xiang

    2017-05-01

    Computed tomography (CT)-guided percutaneous implantation of 125 Iodine radioactive seeds requires the precise arrangement of seeds by tumor shape. We tested whether selecting target areas, including subclinical areas around tumors, can influence locoregional recurrence in patients with non-small cell lung cancer (NSCLC). We divided 82 patients with NSCLC into two groups. Target areas in group 1 (n = 40) were defined along tumor margins based on lung-window CT. Target areas in group 2 (n = 42) were extended by 0.5 cm in all dimensions outside tumor margins. Preoperative plans for both groups were based on a treatment plan system, which guided 125 I seed implantation. Six months later, patients underwent chest CT to evaluate treatment efficacy (per Response Evaluation Criteria in Solid Tumors version 1). We compared locoregional recurrences between the groups after a year of follow-up. We then used the treatment plan system to extend target areas for group 1 patients by 0.5 cm (defined as group 3 data) and compared these hypothetical group 3 planned seeds with the actual seed numbers used in group 1 patients. All patients successfully underwent implantation; none died during the follow-up period. Recurrence was significantly lower in group 2 than in group 1 ( P  < 0.05). Group 1 patients and group 3 data significantly differed in seed numbers ( P  < 0.01). Our results imply that extending the implantation area for 125 I seeds can decrease recurrence risk by eradicating cancerous lymph-duct blockades within the extended areas. © 2017 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  12. Coverage-based constraints for IMRT optimization

    NASA Astrophysics Data System (ADS)

    Mescher, H.; Ulrich, S.; Bangert, M.

    2017-09-01

    Radiation therapy treatment planning requires an incorporation of uncertainties in order to guarantee an adequate irradiation of the tumor volumes. In current clinical practice, uncertainties are accounted for implicitly with an expansion of the target volume according to generic margin recipes. Alternatively, it is possible to account for uncertainties by explicit minimization of objectives that describe worst-case treatment scenarios, the expectation value of the treatment or the coverage probability of the target volumes during treatment planning. In this note we show that approaches relying on objectives to induce a specific coverage of the clinical target volumes are inevitably sensitive to variation of the relative weighting of the objectives. To address this issue, we introduce coverage-based constraints for intensity-modulated radiation therapy (IMRT) treatment planning. Our implementation follows the concept of coverage-optimized planning that considers explicit error scenarios to calculate and optimize patient-specific probabilities q(\\hat{d}, \\hat{v}) of covering a specific target volume fraction \\hat{v} with a certain dose \\hat{d} . Using a constraint-based reformulation of coverage-based objectives we eliminate the trade-off between coverage and competing objectives during treatment planning. In-depth convergence tests including 324 treatment plan optimizations demonstrate the reliability of coverage-based constraints for varying levels of probability, dose and volume. General clinical applicability of coverage-based constraints is demonstrated for two cases. A sensitivity analysis regarding penalty variations within this planing study based on IMRT treatment planning using (1) coverage-based constraints, (2) coverage-based objectives, (3) probabilistic optimization, (4) robust optimization and (5) conventional margins illustrates the potential benefit of coverage-based constraints that do not require tedious adjustment of target volume objectives.

  13. The promise and perils of HDAC inhibitors in neurodegeneration

    PubMed Central

    Didonna, Alessandro; Opal, Puneet

    2015-01-01

    Histone deacetylases (HDACs) represent emerging therapeutic targets in the context of neurodegeneration. Indeed, pharmacologic inhibition of HDACs activity in the nervous system has shown beneficial effects in several preclinical models of neurological disorders. However, the translation of such therapeutic approach to clinics has been only marginally successful, mainly due to our still limited knowledge about HDACs physiological role particularly in neurons. Here, we review the potential benefits along with the risks of targeting HDACs in light of what we currently know about HDAC activity in the brain. PMID:25642438

  14. Impact of Using Different Four-Dimensional Computed Tomography Data Sets to Design Proton Treatment Plans for Distal Esophageal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pan Xiaoning; Zhang Xiaodong; Li Yupeng

    2009-02-01

    Purpose: To study the impact of selecting different data sets from four-dimensional computed tomography (4D CT) imaging during proton treatment planning in patients with distal esophageal cancer. Methods and Materials: We examined the effects of changes in 4D CT data set and smearing margins in proton treatment planning for 5 patients with distal esophageal cancer whose diaphragms were in the beam path and could move several centimeters during respiration. Planning strategies based on (1) average, (2) inspiration, and (3) expiration CT were evaluated in terms of their coverage on the internal clinic target volume (ICTV) at the prescribed dose. Results:more » For Strategy 1, increasing the smearing margin caused an increase in the ICTV prescription dose coverage (PDC) at the end-exhalation phase for all patients, whereas the ICTV PDC decreased for some patients at the end-inhalation phase. For Strategy 2, a smearing margin in the range of 1.0 to 3.5 cm caused the ICTV PDC to remain essentially unchanged, regardless of which phase of 4D CT was used for dose calculation, for all patients. For Strategy 3, the ICTV coverage was adequate for 2 of the 5 patients when a smearing margin of less than 1.0 cm was used, but was not adequate for the other 3 patients regardless of the smearing margin. Conclusion: Using the inspiration CT plus a smearing margin can lead to adequate ICTV coverage in treatment plans for patients with distal esophageal tumors surrounded by tissue that is subject to large changes in density during a proton treatment.« less

  15. TU-D-202-03: Gating Is the Best ITV Killer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Low, D.

    Respiratory motion has long been recognized as an important factor affecting the precision of radiotherapy. After the introduction of the 4D CT to visualize the respiratory motion in 3D, the internal target volume (ITV) has been widely adopted as simple method to take the motion into account in treatment planning and delivery. The ITV is generated as the union of the CTVs as the patient goes through the respiratory cycle. Many issues have been identified with the ITV. In this session three alternatives for the ITV will be discussed: 1) An alternative motion-inclusive approach with better imaging and smaller margins,more » called mid-position CT. 2) The tracking approach and 3) The gating approach. The following topics will be addressed by Marcel van Herk (“Is ITV the correct motion encompassing strategy”): Magnitude of respiratory motion, effect of motion on radiotherapy, motion encompassing strategies, and software solutions to assist in motion encompassing strategies. Then Paul Keall (“Make margins simple: Use real-time target tracking”) will discuss tracking with: clinical drivers for tracking, current clinical status of tumor tracking, future tumor tracking technology, and margin margin challenges with and without tracking. Finally Daniel Low will discuss gating (“Gating is the best ITV killer”): why ITV in the first place, requirements for planning, requirements at the machine, benefits and costs. The session will end with a discussion and live demo of motion simulation software to illustrate the issues and explain the relative benefit and appropriate uses for the three methods. Learning Objectives: Explain the 4D imaging and treatment planning process. Summarize the various approaches to deal with respiratory motion during radiotherapy Discuss the tradeoffs involved when choosing one of the three discussed approaches. Explain in which situation each method is the best choice Research is partly funded by Elekta Oncology Systems and the Dutch Cancer Foundation; M. van Herk, Part of the research was funded by Elekta Oncology Systems and the Dutch Cancer Foundation.« less

  16. SU-E-J-88: The Study of Setup Error Measured by CBCT in Postoperative Radiotherapy for Cervical Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Runxiao, L; Aikun, W; Xiaomei, F

    2015-06-15

    Purpose: To compare two registration methods in the CBCT guided radiotherapy for cervical carcinoma, analyze the setup errors and registration methods, determine the margin required for clinical target volume(CTV) extending to planning target volume(PTV). Methods: Twenty patients with cervical carcinoma were enrolled. All patients were underwent CT simulation in the supine position. Transfering the CT images to the treatment planning system and defining the CTV, PTV and the organs at risk (OAR), then transmit them to the XVI workshop. CBCT scans were performed before radiotherapy and registered to planning CT images according to bone and gray value registration methods. Comparedmore » two methods and obtain left-right(X), superior-inferior(Y), anterior-posterior (Z) setup errors, the margin required for CTV to PTV were calculated. Results: Setup errors were unavoidable in postoperative cervical carcinoma irradiation. The setup errors measured by method of bone (systemic ± random) on X(1eft.right),Y(superior.inferior),Z(anterior.posterior) directions were(0.24±3.62),(0.77±5.05) and (0.13±3.89)mm, respectively, the setup errors measured by method of grey (systemic ± random) on X(1eft-right), Y(superior-inferior), Z(anterior-posterior) directions were(0.31±3.93), (0.85±5.16) and (0.21±4.12)mm, respectively.The spatial distributions of setup error was maximum in Y direction. The margins were 4 mm in X axis, 6 mm in Y axis, 4 mm in Z axis respectively.These two registration methods were similar and highly recommended. Conclusion: Both bone and grey registration methods could offer an accurate setup error. The influence of setup errors of a PTV margin would be suggested by 4mm, 4mm and 6mm on X, Y and Z directions for postoperative radiotherapy for cervical carcinoma.« less

  17. Analysis of Geometric Shifts and Proper Setup-Margin in Prostate Cancer Patients Treated With Pelvic Intensity-Modulated Radiotherapy Using Endorectal Ballooning and Daily Enema for Prostate Immobilization.

    PubMed

    Jeong, Songmi; Lee, Jong Hoon; Chung, Mi Joo; Lee, Sea Won; Lee, Jeong Won; Kang, Dae Gyu; Kim, Sung Hwan

    2016-01-01

    We evaluate geometric shifts of daily setup for evaluating the appropriateness of treatment and determining proper margins for the planning target volume (PTV) in prostate cancer patients.We analyzed 1200 sets of pretreatment megavoltage-CT scans that were acquired from 40 patients with intermediate to high-risk prostate cancer. They received whole pelvic intensity-modulated radiotherapy (IMRT). They underwent daily endorectal ballooning and enema to limit intrapelvic organ movement. The mean and standard deviation (SD) of daily translational shifts in right-to-left (X), anterior-to-posterior (Y), and superior-to-inferior (Z) were evaluated for systemic and random error.The mean ± SD of systemic error (Σ) in X, Y, Z, and roll was 2.21 ± 3.42 mm, -0.67 ± 2.27 mm, 1.05 ± 2.87 mm, and -0.43 ± 0.89°, respectively. The mean ± SD of random error (δ) was 1.95 ± 1.60 mm in X, 1.02 ± 0.50 mm in Y, 1.01 ± 0.48 mm in Z, and 0.37 ± 0.15° in roll. The calculated proper PTV margins that cover >95% of the target on average were 8.20 (X), 5.25 (Y), and 6.45 (Z) mm. Mean systemic geometrical shifts of IMRT were not statistically different in all transitional and three-dimensional shifts from early to late weeks. There was no grade 3 or higher gastrointestinal or genitourianry toxicity.The whole pelvic IMRT technique is a feasible and effective modality that limits intrapelvic organ motion and reduces setup uncertainties. Proper margins for the PTV can be determined by using geometric shifts data.

  18. Analysis of Geometric Shifts and Proper Setup-Margin in Prostate Cancer Patients Treated With Pelvic Intensity-Modulated Radiotherapy Using Endorectal Ballooning and Daily Enema for Prostate Immobilization

    PubMed Central

    Jeong, Songmi; Lee, Jong Hoon; Chung, Mi Joo; Lee, Sea Won; Lee, Jeong Won; Kang, Dae Gyu; Kim, Sung Hwan

    2016-01-01

    Abstract We evaluate geometric shifts of daily setup for evaluating the appropriateness of treatment and determining proper margins for the planning target volume (PTV) in prostate cancer patients. We analyzed 1200 sets of pretreatment megavoltage-CT scans that were acquired from 40 patients with intermediate to high-risk prostate cancer. They received whole pelvic intensity-modulated radiotherapy (IMRT). They underwent daily endorectal ballooning and enema to limit intrapelvic organ movement. The mean and standard deviation (SD) of daily translational shifts in right-to-left (X), anterior-to-posterior (Y), and superior-to-inferior (Z) were evaluated for systemic and random error. The mean ± SD of systemic error (Σ) in X, Y, Z, and roll was 2.21 ± 3.42 mm, −0.67 ± 2.27 mm, 1.05 ± 2.87 mm, and −0.43 ± 0.89°, respectively. The mean ± SD of random error (δ) was 1.95 ± 1.60 mm in X, 1.02 ± 0.50 mm in Y, 1.01 ± 0.48 mm in Z, and 0.37 ± 0.15° in roll. The calculated proper PTV margins that cover >95% of the target on average were 8.20 (X), 5.25 (Y), and 6.45 (Z) mm. Mean systemic geometrical shifts of IMRT were not statistically different in all transitional and three-dimensional shifts from early to late weeks. There was no grade 3 or higher gastrointestinal or genitourianry toxicity. The whole pelvic IMRT technique is a feasible and effective modality that limits intrapelvic organ motion and reduces setup uncertainties. Proper margins for the PTV can be determined by using geometric shifts data. PMID:26765418

  19. Tumor response and negative distal resection margins of rectal cancer after hyperthermochemoradiation therapy.

    PubMed

    Tsutsumi, Soichi; Tabe, Yuichi; Fujii, Takaaki; Yamaguchi, Satoru; Suto, Toshinaga; Yajima, Reina; Morita, Hiroki; Kato, Toshihide; Shioya, Mariko; Saito, Jun-Ichi; Asao, Takayuki; Nakano, Takashi; Kuwano, Hiroyuki

    2011-11-01

    The safety of regional hyperthermia has been tested in locally advanced rectal cancer. The aim of this study was to assess the effects of shorter distal margins on local control and survival in rectal cancer patients who were treated with preoperative hyperthermochemoradiation therapy (HCRT) and underwent rectal resection by using the total mesorectal excision (TME) method. Ninety-three patients with rectal adenocarcinoma who received neoadjuvant HCRT (total radiation: 50 Gy) were included in this study. Surgery was performed 8 weeks after HCRT, and each resected specimen was evaluated histologically. Length of distal surgical margins, status of circumferential margins, pathological response, and tumor node metastasis stage were examined for their effects on recurrence and survival. Fifty-eight (62.4%) patients had tumor regression, and 20 (21.5%) had a pathological complete response. Distal margin length ranged from 1 to 55 mm (median, 21 mm) and did not correlate with local recurrence (p=0.57) or survival (p=0.75) by univariate analysis. Kaplan-Meier estimates of recurrence-free survival and local recurrence for the <10 mm versus ≥10 mm groups were not significantly different. Positive circumferential margins and failure of tumors to respond were unfavorable factors in survival. Distal resection margins that are shorter than 10 mm but are not positive appear to be equivalent to longer margins in patients who undergo HCRT followed by rectal resection with TME. To improve the down-staging rate, additional studies are needed.

  20. Utilization of the Organ Care System Lung for the assessment of lungs from a donor after cardiac death (DCD) before bilateral transplantation.

    PubMed

    Mohite, P N; Sabashnikov, A; García Sáez, D; Pates, B; Zeriouh, M; De Robertis, F; Simon, A R

    2015-07-01

    In this manuscript, we present the first experience of evaluating donation after circulatory death (DCD) lungs, using the normothermic preservation Organ Care System (OCS) and subsequent successful transplantation. The OCS could be a useful tool for the evaluation of marginal lungs from DCD donors as it allows a proper recruitment and bronchoscopy in such donations in addition to continuous ex-vivo perfusion and assessment and treatment during transport. The OCS could potentially be a standard of care in the evaluation of marginal lungs from DCD. © The Author(s) 2014.

Top