Sample records for target strength measurements

  1. Ejecta from Targets Strong and Weak: Experimental Measurements of Strength Controlled and Strengthless Craters

    NASA Astrophysics Data System (ADS)

    Hermalyn, B.

    2014-09-01

    This study presents novel time-resolved 3D measurements of the impact ejecta through crater formation and the arresting process that ceases growth into a variety of targets exhibiting a spectrum of different strengths of interest on planetary bodies.

  2. Target-strength Measurements of Sandfish Arctoscopus japonicus

    NASA Astrophysics Data System (ADS)

    Yoon, Eun-A.; Lee, Kyounghoon; Oh, Wooseok; Choi, Junghwa; Hwang, Kangseok; Kang, Myounghee

    2018-03-01

    The goal of this study was to estimate the target strength (TS) of the sandfish Arctoscopus japonicus using in-situ and ex-situ methods with an echosounder. For the in-situ TS measurement, the survey was conducted by taking hydroacoustic measurements at 38 and 120 kHz and using a coastal gill net, in Goseong, in the northeastern sea of Korea in early December 2009. Ex-situ measurement of TS used live specimens and the tethering method, and was conducted at 120 kHz. The distribution of fork length (FL) was bimodal: 14.6-19.8 cm (n = 241 individuals, mean = 17.0 cm) for males and 16.3-24.5 cm (n = 105 individuals, mean = 19.6 cm) for females. The in-situ TS ranged from -79.8 to -59.1 dB (mean = -74.3 dB for males and -64.1 dB for females) at 38 kHz and -79.9 to -56.2 dB (mean = -74.3 dB for males and -64.1 dB for females) at 120 kHz. The mean TS of females was approximately 10 dB higher than that of males at each dominant frequency. The female ex-situ TS values ranged from 68.5 to -54.6 dB, and those of males was from -67.7 to -59.3 dB. The mean TS value for females was 2.9 dB higher than that of males. These results may be used in echo-integration surveys of sandfish to estimate their abundance and seasonal distribution.

  3. A Connection Model between the Positioning Mechanism and Ultrasonic Measurement System via a Web Browser to Assess Acoustic Target Strength

    NASA Astrophysics Data System (ADS)

    Ishii, Ken; Imaizumi, Tomohito; Abe, Koki; Takao, Yoshimi; Tamura, Shuko

    This paper details a network-controlled measurement system for use in fisheries engineering. The target strength (TS) of fish is important in order to convert acoustic integration values obtained during acoustic surveys into estimates of fish abundance. The target strength pattern is measured with the combination of the rotation system for the aspect of the sample and the echo data acquisition system using the underwater supersonic wave. The user interface of the network architecture is designed for collaborative use with researchers in other organizations. The flexible network architecture is based on the web direct-access model for the rotation mechanism. The user interface is available for monitoring and controlling via a web browser that is installed in any terminal PC (personal computer). Previously the combination of two applications was performed not by a web browser but by the exclusive interface program. So a connection model is proposed between two applications by indirect communication via the DCOM (Distributed Component Object Model) server and added in the web direct-access model. A prompt report system in the TS measurement system and a positioning and measurement system using an electric flatcar via a web browser are developed. By a secure network architecture, DCOM communications via both Intranet and LAN are successfully certificated.

  4. Controlled and in situ target strengths of the jumbo squid Dosidicus gigas and identification of potential acoustic scattering sources.

    PubMed

    Benoit-Bird, Kelly J; Gilly, William F; Au, Whitlow W L; Mate, Bruce

    2008-03-01

    This study presents the first target strength measurements of Dosidicus gigas, a large squid that is a key predator, a significant prey, and the target of an important fishery. Target strength of live, tethered squid was related to mantle length with values standardized to the length squared of -62.0, -67.4, -67.9, and -67.6 dB at 38, 70, 120, and 200 kHz, respectively. There were relatively small differences in target strength between dorsal and anterior aspects and none between live and freshly dead squid. Potential scattering mechanisms in squid have been long debated. Here, the reproductive organs had little effect on squid target strength. These data support the hypothesis that the pen may be an important source of squid acoustic scattering. The beak, eyes, and arms, probably via the sucker rings, also play a role in acoustic scattering though their effects were small and frequency specific. An unexpected source of scattering was the cranium of the squid which provided a target strength nearly as high as that of the entire squid though the mechanism remains unclear. Our in situ measurements of the target strength of free-swimming squid support the use of the values presented here in D. gigas assessment studies.

  5. Motor development in individuals with congenital adrenal hyperplasia: strength, targeting, and fine motor skill.

    PubMed

    Collaer, Marcia L; Brook, Charles G D; Conway, Gerard S; Hindmarsh, Peter C; Hines, Melissa

    2009-02-01

    This study investigated early androgen influence on the development of human motor and visuomotor characteristics. Participants, ages 12-45 years, were individuals with congenital adrenal hyperplasia (CAH), a disorder causing increased adrenal androgen production before birth (40 females, 29 males) and their unaffected relatives (29 females, 30 males). We investigated grip strength and visuomotor targeting tasks on which males generally outperform females, and fine motor pegboard tasks on which females generally outperform males. Physical characteristics (height and weight) were measured to explore whether body parameters could explain differences in motor skills. Females with CAH were stronger and showed better targeting than unaffected females and showed reduced fine visuomotor skill on one pegboard measure, with no difference on the other. Males with CAH were weaker than unaffected males in grip strength but did not differ on the targeting or pegboard measures. Correction for body size could not explain the findings for females, but suggests that the reduced strength of males with CAH may relate to their smaller stature. Further, the targeting advantage in females with CAH persisted following adjustment for their greater strength. Results in females support the hypothesis that androgen may masculinize, or promote, certain motor characteristics at which males excel, and contribute to defeminization of certain fine motor characteristics at which females excel. Thus, these data suggest that organizational effects of androgens on behavior during prenatal life may extend to motor characteristics and may contribute to general sex differences in motor-related behaviors; however, alternative explanations based on activational influences of androgen or altered experiential factors cannot be excluded without further study.

  6. Target Strength of Southern Resident Killer Whales (Orcinus orca): Measurement and Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Jinshan; Deng, Zhiqun; Carlson, Thomas J.

    2012-04-04

    A major criterion for tidal power licensing in Washington’s Puget Sound is the management of the risk of injury to killer whales due to collision with moving turbine blades. An active monitoring system is being proposed for killer whale detection, tracking, and alerting that links to and triggers temporary turbine shutdown when there is risk of collision. Target strength (TS) modeling of the killer whale is critical to the design and application of any active monitoring system. A 1996 study performed a high-resolution measurement of acoustic reflectivity as a function of frequency of a female bottlenose dolphin (2.2 m length)more » at broadside aspect and TS as a function of incident angle at 67 kHz frequency. Assuming that killer whales share similar morphology structure with the bottlenose dolphin, we extrapolated the TS of an adult killer whale 7.5 m in length at 67 kHz frequency with -8 dB at broadside aspect and -28 dB at tail side. The backscattering data from three Southern Resident killer whales were analyzed to obtain the TS measurement. These data were collected at Lime Kiln State Park using a split-beam system deployed from a boat. The TS of the killer whale at higher frequency (200 kHz) was estimated based on a three-layer model for plane wave reflection from the lung of the whale. The TS data of killer whales were in good agreement with our model. In this paper, we also discuss and explain possible causes for measurement estimation error.« less

  7. Material strength measured by flyer-impact perturbation method

    NASA Astrophysics Data System (ADS)

    Ma, Xiaojuan; Asimow, Paul; Fatyanov, Oleg; Liu, Fusheng

    2017-06-01

    Yield strength is one of the most important physical properties of a solid material, especially far from its melting line. The flyer-impact perturbation method measures material yield strength on the basis of correlation between the yield strength under shock compression and the damping of oscillatory perturbations in the shape of a shock front passing through the material. We used flyer-plate impacts experiments on targets with machined grooves on the impact surface to shock aluminum to between 32 and 71 GPa and recorded the evolution of the shock front perturbation amplitude in the sample with electric pins and fibers. Simulations using the elastic-plastic model can be matched to the experiments, explaining well the form of the perturbation decay and constraining the yield strength of aluminum to be 1.3-3.1 GPa. These results are in agreement with values obtained from reshock and release wave profiles as well as the result deduced from the SCG model. We conclude that the flyer-impact perturbation method is indeed a reliable means to measure material strength. This work was supported by the National Natural Science Foundation of China (Grant No. 41674088) and the State Scholarship Fund of China Scholarship Council.

  8. Techniques for Strength Measurement at High Pressures and Strain-Rates Using Transverse Waves

    NASA Astrophysics Data System (ADS)

    Richmond, Victoria Stolyar

    The study of the strength of a material is relevant to a variety of applications including automobile collisions, armor penetration and inertial confinement fusion. Although dynamic behavior of materials at high pressures and strain-rates has been studied extensively using plate impact experiments, the results provide measurements in one direction only. Material behavior that is dependent on strength is unaccounted for. The research in this study proposes two novel configurations to mitigate this problem. The first configuration introduced is the oblique wedge experiment, which is comprised of a driver material, an angled target of interest and a backing material used to measure in-situ velocities. Upon impact, a shock wave is generated in the driver material. As the shock encounters the angled target, it is reflected back into the driver and transmitted into the target. Due to the angle of obliquity of the incident wave, a transverse wave is generated that allows the target to be subjected to shear while being compressed by the initial longitudinal shock such that the material does not slip. Using numerical simulations, this study shows that a variety of oblique wedge configurations can be used to study the shear response of materials and this can be extended to strength measurement as well. Experiments were performed on an oblique wedge setup with a copper impactor, polymethylmethacrylate driver, aluminum 6061-t6 target, and a lithium fluoride window. Particle velocities were measured using laser interferometry and results agree well with the simulations. The second novel configuration is the y-cut quartz sandwich design, which uses the anisotropic properties of y-cut quartz to generate a shear wave that is transmitted into a thin sample. By using an anvil material to back the thin sample, particle velocities measured at the rear surface of the backing plate can be implemented to calculate the shear stress in the material and subsequently the strength. Numerical

  9. Planetary and Primitive Object Strength Measurements and Sampling Apparatus

    NASA Technical Reports Server (NTRS)

    Ahrens, Thomas J.

    1997-01-01

    We present experimental data and a model for the low-velocity (subsonic, 0 - 1000 m/s) penetration of brittle materials by both solid and hollow (i.e., coring) penetrators. The experiments show that penetration is proportional to momentum/frontal area of the penetrator. Because of the buildup of a cap in front of blunt penetrators, the presence or absence of a streamlined or sharp front end usually has a negligible effect for impact into targets with strength. The model accurately predicts the dependence of penetration depth on the various parameters of the target-penetrator system, as well as the qualitative condition of the target material ingested by a corer. In particular, penetration depth is approximately inversely proportional to the static bearing strength of the target. The bulk density of the target material has only a small effect on penetration, whereas friction can be significant, especially at higher impact velocities, for consolidated materials. This trend is reversed for impacts into unconsolidated materials. The present results suggest that the depth of penetration is a good measure of the strength, but not the density, of a consolidated target. Both experiments and model results show that, if passage through the mouth of a coring penetrator requires initially porous target material to be compressed to less than 26% porosity, the sample collected by the corer will be highly fragmented. If the final porosity remains above 26%, then most materials, except cohesionless materials, such as dry sand, will be collected as a compressed slug of material.

  10. Measurement of in-situ strength using projectile penetration: Tests of a new launching system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hearst, J.R.; Newmark, R.L.; Charest, J.A.

    1987-10-01

    The Lawrence Livermore National Laboratory has a continuing need to measure rock strength in situ, both for simple prediction of cavity size, and as input to computational models. In a previous report we compared two methods for measuring formation strength in situ: projectile penetration and a cone penetrometer. We determined that the projectile method was more promising for application to our large-diameter (2-4-m) hole environment. A major practical problem has been the development of a launcher and an apparatus for measuring depth of penetration that would be suitable for use in large-diameter holes. We are developing a gas-gun launcher systemmore » that will be capable of measuring both depth of penetration and deceleration of a reusable projectile. The current version of the launcher is trailer-mounted for testing at our Nevada Test Site (NTS) in tunnels and outcrops, but its design is such that it can be readily adapted for emplacement hole use. We test the current launcher on 60-cm cubes of gypsum cement, mixed to provie a range of densities (1.64 to 2.0 g/cc) and strengths (3 to 17 MPa). We compared depth of penetration of a 84-g projectile from a ''Betsy'' seismic gun - traveling on the order of 500 m/s - with the depth of penetration of a 13-kg projectile from the gas gun - traveling on the order of 30 m/s. For projectiles with the same nose size and shape, impacting targets of approximately constant strength, penetration depth was proportional to projectile kinetic energy. The ratio of kinetic energy to penetration depth was approximately proportional to target strength. Tests in tuffs with a wide range of strengths at NTS gave a similar linear relationship between the ratio of kinetic energy to penetration and target strength, and also a linear relationship between deceleration and strength. It appears that penetration can indeed be used as a semiquantitative measure of strength.« less

  11. Impact cratering on porous targets in the strength regime

    NASA Astrophysics Data System (ADS)

    Nakamura, Akiko M.

    2017-12-01

    Cratering on small bodies is crucial for the collision cascade and also contributes to the ejection of dust particles into interplanetary space. A crater cavity forms against the mechanical strength of the surface, gravitational acceleration, or both. The formation of moderately sized craters that are sufficiently larger than the thickness of the regolith on small bodies, in which mechanical strength plays the dominant role rather than gravitational acceleration, is in the strength regime. The formation of microcraters on blocks on the surface is also within the strength regime. On the other hand, the formation of a crater of a size comparable to the thickness of the regolith is affected by both gravitational acceleration and cohesion between regolith particles. In this short review, we compile data from the literature pertaining to impact cratering experiments on porous targets, and summarize the ratio of spall diameter to pit diameter, the depth, diameter, and volume of the crater cavity, and the ratio of depth to diameter. Among targets with various porosities studied in the laboratory to date, based on conventional scaling laws (Holsapple and Schmidt, J. Geophys. Res., 87, 1849-1870, 1982) the cratering efficiency obtained for porous sedimentary rocks (Suzuki et al., J. Geophys. Res. 117, E08012, 2012) is intermediate. A comparison with microcraters formed on a glass target with impact velocities up to 14 km s-1 indicates a different dependence of cratering efficiency and depth-to-diameter ratio on impact velocity.

  12. The added value of measuring thumb and finger strength when comparing strength measurements in hypoplastic thumb patients.

    PubMed

    Molenaar, H M Ties; Selles, Ruud W; de Kraker, Marjolein; Stam, Henk J; Hovius, Steven E R

    2013-10-01

    When interventions to the hand are aimed at improving function of specific fingers or the thumb, the RIHM (Rotterdam Intrinsic Hand Myometer) is a validated tool and offers more detailed information to assess strength of the involved joints besides grip and pinch measurements. In this study, strength was measured in 65 thumbs in 40 patients diagnosed with thumb hypoplasia. These 65 thumbs were classified according to Blauth. Longitudinal radial deficiencies were also classified. The strength measurements comprised of grip, tip, tripod and key pinch. Furthermore palmar abduction and opposition of the thumb as well as abduction of the index and little finger were measured with the RIHM. For all longitudinal radial deficiency patients, grip and pinch strength as well as palmar abduction and thumb opposition were significantly lower than reference values (P<0.001). However, strength in the index finger abduction and the little finger abduction was maintained or decreased to a lesser extent according to the degree of longitudinal radial deficiency. All strength values decreased with increasing Blauth-type. Blauth-type II hands (n=15) with flexor digitorum superficialis 4 opposition transfer including stabilization of the metacarpophalangeal joint showed a trend toward a higher opposition strength without reaching statistical significance (P=0.094),however compared to non-operated Blauth-type II hands (n=6) they showed a lower grip strength (P=0.019). The RIHM is comparable in accuracy to other strength dynamometers. Using the RIHM, we were able to illustrate strength patterns on finger-specific level, showing added value when evaluating outcome in patients with hand related problems. © 2013.

  13. Ejecta velocity distribution for impact cratering experiments on porous and low strength targets

    NASA Astrophysics Data System (ADS)

    Michikami, Tatsuhiro; Moriguchi, Kouichi; Hasegawa, Sunao; Fujiwara, Akira

    2007-01-01

    Impact cratering experiments on porous targets with various compressive strength ranging from ˜0.5 to ˜250 MPa were carried out in order to investigate the relationship between the ejecta velocity, and material strength or porosity of the target. A spherical alumina projectile (diameter ˜1 mm) was shot perpendicularly into the target surface with velocity ranging from 1.2 to 4.5 km/s (nominal 4 km/s), using a two-stage light-gas gun. The ejecta velocity was estimated from the fall point distance of ejecta. The results show that there are in fact a large fraction of ejecta with very low velocities when the material strength of the target is small and the porosity is high. As an example, in the case of one specific target (compressive strength ˜0.5 MPa and porosity 43%), the amount of ejecta with velocities lower than 1 m/s is about 40% of the total mass. The average velocity of the ejecta decreases with decreasing material strength or increasing the porosity of the target. Moreover, in our experiments, the ejecta velocity distributions normalized to total ejecta mass seem to be mainly dependent on the material strength of the target, and not so greatly on the porosity. We also compare our experimental results with those of Gault et al. [1963. Spray ejected from the lunar surface by meteoroid impact. NASA Technical Note D-1767] and Housen [1992. Crater ejecta velocities for impacts on rocky bodies. LPSC XXIII, 555-556] for the ejecta velocity distribution using Housen's nondimensional scaling parameter. The ejecta velocity distributions of our experiments are lower than those of Gault et al. [1963. Spray ejected from the lunar surface by meteoroid impact. NASA Technical Note D-1767] and Housen [1992. Crater ejecta velocities for impacts on rocky bodies. LPSC XIII, 555-556].

  14. Yield strength measurement of shock-loaded metal by flyer-impact perturbation method

    NASA Astrophysics Data System (ADS)

    Ma, Xiaojuan; Shi, Zhan

    2018-06-01

    Yield strength is one of the most important physical properties of a solid material, especially far from its melting line. The flyer-impact perturbation method measures material yield strength on the basis of correlation between the yield strength under shock compression and the damping of oscillatory perturbations in the shape of a shock front passing through the material. We used flyer-impact experiments on targets with machined grooves on the impact surface of shock 6061-T6 aluminum to between 32 and 61 GPa and recorded the evolution of the shock front perturbation amplitude in the sample with electric pins. Simulations using the elastic-plastic model can be matched to the experiments, explaining well the form of the perturbation decay and constraining the yield strength of 6061-T6 aluminum to be 1.31-1.75 GPa. These results are in agreement with values obtained from reshock and release wave profiles. We conclude that the flyer-impact perturbation method is indeed a new means to measure material strength.

  15. An Improved Measurement Method for the Strength of Radiation of Reflective Beam in an Industrial Optical Sensor Based on Laser Displacement Meter.

    PubMed

    Bae, Youngchul

    2016-05-23

    An optical sensor such as a laser range finder (LRF) or laser displacement meter (LDM) uses reflected and returned laser beam from a target. The optical sensor has been mainly used to measure the distance between a launch position and the target. However, optical sensor based LRF and LDM have numerous and various errors such as statistical errors, drift errors, cyclic errors, alignment errors and slope errors. Among these errors, an alignment error that contains measurement error for the strength of radiation of returned laser beam from the target is the most serious error in industrial optical sensors. It is caused by the dependence of the measurement offset upon the strength of radiation of returned beam incident upon the focusing lens from the target. In this paper, in order to solve these problems, we propose a novel method for the measurement of the output of direct current (DC) voltage that is proportional to the strength of radiation of returned laser beam in the received avalanche photo diode (APD) circuit. We implemented a measuring circuit that is able to provide an exact measurement of reflected laser beam. By using the proposed method, we can measure the intensity or strength of radiation of laser beam in real time and with a high degree of precision.

  16. An Improved Measurement Method for the Strength of Radiation of Reflective Beam in an Industrial Optical Sensor Based on Laser Displacement Meter

    PubMed Central

    Bae, Youngchul

    2016-01-01

    An optical sensor such as a laser range finder (LRF) or laser displacement meter (LDM) uses reflected and returned laser beam from a target. The optical sensor has been mainly used to measure the distance between a launch position and the target. However, optical sensor based LRF and LDM have numerous and various errors such as statistical errors, drift errors, cyclic errors, alignment errors and slope errors. Among these errors, an alignment error that contains measurement error for the strength of radiation of returned laser beam from the target is the most serious error in industrial optical sensors. It is caused by the dependence of the measurement offset upon the strength of radiation of returned beam incident upon the focusing lens from the target. In this paper, in order to solve these problems, we propose a novel method for the measurement of the output of direct current (DC) voltage that is proportional to the strength of radiation of returned laser beam in the received avalanche photo diode (APD) circuit. We implemented a measuring circuit that is able to provide an exact measurement of reflected laser beam. By using the proposed method, we can measure the intensity or strength of radiation of laser beam in real time and with a high degree of precision. PMID:27223291

  17. Invariance of evoked-potential echo-responses to target strength and distance in an echolocating false killer whale

    NASA Astrophysics Data System (ADS)

    Supin, Alexander Ya.; Nachtigall, Paul E.; Au, Whitlow W. L.; Breese, Marlee

    2005-06-01

    Brain auditory evoked potentials (AEPs) were recorded in a false killer whale Pseudorca crassidens trained to accept suction-cup EEG electrodes and to detect targets by echolocation. AEP collection was triggered by echolocation pulses transmitted by the animal. The target strength varied from -22 to -40 dB the distance varied from 1.5 to 6 m. All the records contained two AEP sets: the first one of a constant latency (transmission-related AEP) and a second one with a delay proportional to the distance (echo-related AEP). The amplitude of echo-related AEPs was almost independent of both target strength and distance, though combined variation of these two parameters resulted in echo intensity variation within a range of 42 dB. The amplitude of transmission-related AEPs was independent of distance but dependent on target strength: the less the target strength, the higher the amplitude. Recording of transmitted pulses has not shown their intensity dependence on target strength. It is supposed that the constancy of echo-related AEP results from variation of hearing sensitivity depending on the target strength and release of echo-related responses from masking by transmitted pulses depending on the distance. .

  18. Invariance of evoked-potential echo-responses to target strength and distance in an echolocating false killer whale.

    PubMed

    Supin, Alexander Ya; Nachtigall, Paul E; Au, Whitlow W L; Breese, Marlee

    2005-06-01

    Brain auditory evoked potentials (AEPs) were recorded in a false killer whale Pseudorca crassidens trained to accept suction-cup EEG electrodes and to detect targets by echolocation. AEP collection was triggered by echolocation pulses transmitted by the animal. The target strength varied from -22 to -40 dB; the distance varied from 1.5 to 6 m. All the records contained two AEP sets: the first one of a constant latency (transmission-related AEP) and a second one with a delay proportional to the distance (echo-related AEP). The amplitude of echo-related AEPs was almost independent of both target strength and distance, though combined variation of these two parameters resulted in echo intensity variation within a range of 42 dB. The amplitude of transmission-related AEPs was independent of distance but dependent on target strength: the less the target strength, the higher the amplitude. Recording of transmitted pulses has not shown their intensity dependence on target strength. It is supposed that the constancy of echo-related AEP results from variation of hearing sensitivity depending on the target strength and release of echo-related responses from masking by transmitted pulses depending on the distance.

  19. An Improved Compressive Sensing and Received Signal Strength-Based Target Localization Algorithm with Unknown Target Population for Wireless Local Area Networks.

    PubMed

    Yan, Jun; Yu, Kegen; Chen, Ruizhi; Chen, Liang

    2017-05-30

    In this paper a two-phase compressive sensing (CS) and received signal strength (RSS)-based target localization approach is proposed to improve position accuracy by dealing with the unknown target population and the effect of grid dimensions on position error. In the coarse localization phase, by formulating target localization as a sparse signal recovery problem, grids with recovery vector components greater than a threshold are chosen as the candidate target grids. In the fine localization phase, by partitioning each candidate grid, the target position in a grid is iteratively refined by using the minimum residual error rule and the least-squares technique. When all the candidate target grids are iteratively partitioned and the measurement matrix is updated, the recovery vector is re-estimated. Threshold-based detection is employed again to determine the target grids and hence the target population. As a consequence, both the target population and the position estimation accuracy can be significantly improved. Simulation results demonstrate that the proposed approach achieves the best accuracy among all the algorithms compared.

  20. 47 CFR 73.686 - Field strength measurements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... earth radius, of the largest available scale. (c) Collection of field strength data to determine... through the measurement area. (iii) Antenna elevation. When field strength is being measured for a one....686 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO...

  1. 47 CFR 73.686 - Field strength measurements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... earth radius, of the largest available scale. (c) Collection of field strength data to determine... through the measurement area. (iii) Antenna elevation. When field strength is being measured for a one....686 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO...

  2. 47 CFR 73.686 - Field strength measurements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... earth radius, of the largest available scale. (c) Collection of field strength data to determine... through the measurement area. (iii) Antenna elevation. When field strength is being measured for a one....686 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO...

  3. 47 CFR 73.686 - Field strength measurements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... earth radius, of the largest available scale. (c) Collection of field strength data to determine... through the measurement area. (iii) Antenna elevation. When field strength is being measured for a one....686 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO...

  4. Importance and challenges of measuring intrinsic foot muscle strength

    PubMed Central

    2012-01-01

    Background Intrinsic foot muscle weakness has been implicated in a range of foot deformities and disorders. However, to establish a relationship between intrinsic muscle weakness and foot pathology, an objective measure of intrinsic muscle strength is needed. The aim of this review was to provide an overview of the anatomy and role of intrinsic foot muscles, implications of intrinsic weakness and evaluate the different methods used to measure intrinsic foot muscle strength. Method Literature was sourced from database searches of MEDLINE, PubMed, SCOPUS, Cochrane Library, PEDro and CINAHL up to June 2012. Results There is no widely accepted method of measuring intrinsic foot muscle strength. Methods to estimate toe flexor muscle strength include the paper grip test, plantar pressure, toe dynamometry, and the intrinsic positive test. Hand-held dynamometry has excellent interrater and intrarater reliability and limits toe curling, which is an action hypothesised to activate extrinsic toe flexor muscles. However, it is unclear whether any method can actually isolate intrinsic muscle strength. Also most methods measure only toe flexor strength and other actions such as toe extension and abduction have not been adequately assessed. Indirect methods to investigate intrinsic muscle structure and performance include CT, ultrasonography, MRI, EMG, and muscle biopsy. Indirect methods often discriminate between intrinsic and extrinsic muscles, but lack the ability to measure muscle force. Conclusions There are many challenges to accurately measure intrinsic muscle strength in isolation. Most studies have measured toe flexor strength as a surrogate measure of intrinsic muscle strength. Hand-held dynamometry appears to be a promising method of estimating intrinsic muscle strength. However, the contribution of extrinsic muscles cannot be excluded from toe flexor strength measurement. Future research should clarify the relative contribution of intrinsic and extrinsic muscles

  5. The Strengths Assessment Inventory: Reliability of a New Measure of Psychosocial Strengths for Youth

    ERIC Educational Resources Information Center

    Brazeau, James N.; Teatero, Missy L.; Rawana, Edward P.; Brownlee, Keith; Blanchette, Loretta R.

    2012-01-01

    A new measure, the Strengths Assessment Inventory-Youth self-report (SAI-Y), was recently developed to assess the strengths of children and adolescents between the ages of 10 and 18 years. The SAI-Y differs from similar measures in that it provides a comprehensive assessment of strengths that are intrinsic to the individual as well as strengths…

  6. A three-dimensional computerized isometric strength measurement system.

    PubMed

    Black, Nancy L; Das, Biman

    2007-05-01

    The three-dimensional Computerized Isometric Strength Measurement System (CISMS) reliably and accurately measures isometric pull and push strengths in work spaces of paraplegic populations while anticipating comparative studies with other populations. The main elements of the system were: an extendable arm, a vertical supporting track, a rotating platform, a force transducer, stability sensors and a computerized data collection interface. The CISMS with minor modification was successfully used to measure isometric push-up and pull-down strengths of paraplegics and isometric push, pull, push-up and pull-down strength in work spaces for seated and standing able-bodied populations. The instrument has satisfied criteria of versatility, safety and comfort, ease of operation, and durability. Results are accurate within 2N for aligned forces. Costing approximately $1,500 (US) including computer, the system is affordable and accurate for aligned isometric strength measurements.

  7. Relationship between agility and lower limb muscle strength, targeting university badminton players.

    PubMed

    Sonoda, Takuya; Tashiro, Yuto; Suzuki, Yusuke; Kajiwara, Yu; Zeidan, Hala; Yokota, Yuki; Kawagoe, Mirei; Nakayama, Yasuaki; Bito, Tsubasa; Shimoura, Kanako; Tatsumi, Masataka; Nakai, Kengo; Nishida, Yuichi; Yoshimi, Soyoka; Aoyama, Tomoki

    2018-02-01

    [Purpose] Targeting university badminton players, this study investigated the relationship between agility, which is associated with performance in badminton, and lower limb muscle strength, and examined which muscles influence agility. [Subjects and Methods] A total of 23 male university badminton players were evaluated for side-shuffle test scores and lower limb strength. The relationships between agility, lower limb strength, and duration of experience playing badminton were evaluated using a correlation analysis. Moreover, the relationship between agility and lower limb strength was evaluated by partial correlation analysis, adjusting for the effects of experience of each badminton player. [Results] The agility score correlated with hip extension and ankle plantar flexion strength, with adjustment for badminton experience. [Conclusion] This study suggests that hip extension training and improvement in ankle plantar flexion strength may improve agility.

  8. Ultrasound transmission measurements for tensile strength evaluation of tablets.

    PubMed

    Simonaho, Simo-Pekka; Takala, T Aleksi; Kuosmanen, Marko; Ketolainen, Jarkko

    2011-05-16

    Ultrasound transmission measurements were performed to evaluate the tensile strength of tablets. Tablets consisting of one ingredient were compressed from dibasic calcium phosphate dehydrate, two grades of microcrystalline cellulose and two grades of lactose monohydrate powders. From each powder, tablets with five different tensile strengths were directly compressed. Ultrasound transmission measurements were conducted on every tablet at frequencies of 2.25 MHz, 5 MHz and 10 MHz and the speed of sound was calculated from the acquired waveforms. The tensile strength of the tablets was determined using a diametrical mechanical testing machine and compared to the calculated speed of sound values. It was found that the speed of sound increased with the tensile strength for the tested excipients. There was a good correlation between the speed of sound and tensile strength. Moreover, based on the statistical tests, the groups with different tensile strengths can be differentiated from each other by measuring the speed of sound. Thus, the ultrasound transmission measurement technique is a potentially useful method for non-destructive and fast evaluation of the tensile strength of tablets. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Brand Discrimination: An Implicit Measure of the Strength of Mental Brand Representations

    PubMed Central

    Friedman, Mike; Leclercq, Thomas

    2015-01-01

    While mental associations between a brand and its marketing elements are an important part of brand equity, previous research has yet to provide a sound methodology to measure the strength of these links. The following studies present the development and validation of an implicit measure to assess the strength of mental representations of brand elements in the mind of the consumer. The measure described in this paper, which we call the Brand Discrimination task, requires participants to identify whether images of brand elements (e.g. color, logo, packaging) belong to a target brand or not. Signal detection theory (SDT) is used to calculate a Brand Discrimination index which gives a measure of overall recognition accuracy for a brand’s elements in the context of its competitors. A series of five studies shows that the Brand Discrimination task can discriminate between strong and weak brands, increases when mental representations of brands are experimentally strengthened, is relatively stable across time, and can predict brand choice, independently and while controlling for other explicit and implicit brand evaluation measures. Together, these studies provide unique evidence for the importance of mental brand representations in marketing and consumer behavior, along with a research methodology to measure this important consumer-based brand attribute. PMID:25803845

  10. Brand discrimination: an implicit measure of the strength of mental brand representations.

    PubMed

    Friedman, Mike; Leclercq, Thomas

    2015-01-01

    While mental associations between a brand and its marketing elements are an important part of brand equity, previous research has yet to provide a sound methodology to measure the strength of these links. The following studies present the development and validation of an implicit measure to assess the strength of mental representations of brand elements in the mind of the consumer. The measure described in this paper, which we call the Brand Discrimination task, requires participants to identify whether images of brand elements (e.g. color, logo, packaging) belong to a target brand or not. Signal detection theory (SDT) is used to calculate a Brand Discrimination index which gives a measure of overall recognition accuracy for a brand's elements in the context of its competitors. A series of five studies shows that the Brand Discrimination task can discriminate between strong and weak brands, increases when mental representations of brands are experimentally strengthened, is relatively stable across time, and can predict brand choice, independently and while controlling for other explicit and implicit brand evaluation measures. Together, these studies provide unique evidence for the importance of mental brand representations in marketing and consumer behavior, along with a research methodology to measure this important consumer-based brand attribute.

  11. Development of a Force Measurement Device for Lower-Body Muscular Strength Measuring of Skaters

    NASA Astrophysics Data System (ADS)

    Kim, Dong Ki; Lee, Jeong Tae

    This paper presents a force measurement system that can measure a lower-body muscular strength of skaters. The precise measurement and analysis of the left and right lower-body strength of skaters is necessary, because a left/right lower-body strength balance is helpful to improve the athletes' performance and to protect them from injury. The system is constructed with a skate sliding board, a couple of sensor-units with load cell, indicator and control box, guard, force pad, and support bracket. The developed force measurement system is calibrated by the calibration setup, and the uncertainty of the force sensing unit on the left is within 0.087% and the uncertainty of the force sensing unit on the right is within 0.109%. In order to check the feasibility of the developed measurement device, a kinematic analysis is conducted with skater. As a result, the subject shows the deviation of left and right of 12.1 N with respect to average strength and 39.1 N with respect to the maximum strength. This evaluation results are reliable enough to make it possible to measure a lower-body muscular strength of skaters. The use of this measurement system will be expected to correct the posture of skaters and record the sports dynamics data for each athlete. It is believed that through the development of this equipment, skaters in elementary, middle, high schools, colleges, and the professional level have the systematic training to compete with world-class skaters.

  12. A rail system for circular synthetic aperture sonar imaging and acoustic target strength measurements: design/operation/preliminary results.

    PubMed

    Kennedy, J L; Marston, T M; Lee, K; Lopes, J L; Lim, R

    2014-01-01

    A 22 m diameter circular rail, outfitted with a mobile sonar tower trolley, was designed, fabricated, instrumented with underwater acoustic transducers, and assembled on a 1.5 m thick sand layer at the bottom of a large freshwater pool to carry out sonar design and target scattering response studies. The mobile sonar tower translates along the rail via a drive motor controlled by customized LabVIEW software. The rail system is modular and assembly consists of separately deploying eight circular arc sections, measuring a nominal center radius of 11 m and 8.64 m arc length each, and having divers connect them together in the underwater environment. The system enables full scale measurements on targets of interest with 0.1° angular resolution over a complete 360° aperture, without disrupting target setup, and affording a level of control over target environment conditions and noise sources unachievable in standard field measurements. In recent use, the mobile cart carrying an instrumented sonar tower was translated along the rail in 720 equal position increments and acoustic backscatter data were acquired at each position. In addition, this system can accommodate both broadband monostatic and bistatic scattering measurements on targets of interest, allowing capture of target signature phenomena under diverse configurations to address current scientific and technical issues encountered in mine countermeasure and unexploded ordnance applications. In the work discussed here, the circular rail apparatus is used for acoustic backscatter testing, but this system also has the capacity to facilitate the acquisition of magnetic and optical sensor data from targets of interest. A brief description of the system design and operation will be presented along with preliminary processed results for data acquired from acoustic measurements conducted at the Naval Surface Warfare Center, Panama City Division Test Pond Facility. [Work Supported by the U.S. Office of Naval Research and

  13. A rail system for circular synthetic aperture sonar imaging and acoustic target strength measurements: Design/operation/preliminary results

    NASA Astrophysics Data System (ADS)

    Kennedy, J. L.; Marston, T. M.; Lee, K.; Lopes, J. L.; Lim, R.

    2014-01-01

    A 22 m diameter circular rail, outfitted with a mobile sonar tower trolley, was designed, fabricated, instrumented with underwater acoustic transducers, and assembled on a 1.5 m thick sand layer at the bottom of a large freshwater pool to carry out sonar design and target scattering response studies. The mobile sonar tower translates along the rail via a drive motor controlled by customized LabVIEW software. The rail system is modular and assembly consists of separately deploying eight circular arc sections, measuring a nominal center radius of 11 m and 8.64 m arc length each, and having divers connect them together in the underwater environment. The system enables full scale measurements on targets of interest with 0.1° angular resolution over a complete 360° aperture, without disrupting target setup, and affording a level of control over target environment conditions and noise sources unachievable in standard field measurements. In recent use, the mobile cart carrying an instrumented sonar tower was translated along the rail in 720 equal position increments and acoustic backscatter data were acquired at each position. In addition, this system can accommodate both broadband monostatic and bistatic scattering measurements on targets of interest, allowing capture of target signature phenomena under diverse configurations to address current scientific and technical issues encountered in mine countermeasure and unexploded ordnance applications. In the work discussed here, the circular rail apparatus is used for acoustic backscatter testing, but this system also has the capacity to facilitate the acquisition of magnetic and optical sensor data from targets of interest. A brief description of the system design and operation will be presented along with preliminary processed results for data acquired from acoustic measurements conducted at the Naval Surface Warfare Center, Panama City Division Test Pond Facility. [Work Supported by the U.S. Office of Naval Research and

  14. Target strengths of two abundant mesopelagic fish species.

    PubMed

    Scoulding, Ben; Chu, Dezhang; Ona, Egil; Fernandes, Paul G

    2015-02-01

    Mesopelagic fish of the Myctophidae and Sternoptychidae families dominate the biomass of the oceanic deep scattering layers and, therefore, have important ecological roles within these ecosystems. Interest in the commercial exploitation of these fish is growing, so the development of techniques for estimating their abundance, distribution and, ultimately, sustainable exploitation are essential. The acoustic backscattering characteristics for two size classes of Maurolicus muelleri and Benthosema glaciale are reported here based on swimbladder morphology derived from digitized soft x-ray images, and empirical (in situ) measurements of target strength (TS) derived from an acoustic survey in a Norwegian Sea. A backscattering model based on a gas-filled prolate spheroid was used to predict the theoretical TS for both species across a frequency range between 0 and 250 kHz. Sensitivity analyses of the TS model to the modeling parameters indicate that TS is rather sensitive to the viscosity, swimbladder volume ratio, and tilt, which can result in substantial changes to the TS. Theoretical TS predictions close to the resonance frequency were in good agreement (±2 dB) with mean in situ TS derived from the areas acoustically surveyed that were spatially and temporally consistent with the trawl information for both species.

  15. An apparatus to measure the crosscut shearing strength of roots

    Treesearch

    Robert R. Ziemer

    1978-01-01

    Loss of tree root strength after timber cutting is a principal mechanism leading to slope failure and landslides. Measurement of root shear strength changes can be useful in evaluating effects of logging on slope stability. The simple apparatus described measures shear strength directly on roots up to 50 mm diameter. Tests on live roots showed excellent correlation...

  16. Quantitative measures of walking and strength provide insight into brain corticospinal tract pathology in multiple sclerosis.

    PubMed

    Fritz, Nora E; Keller, Jennifer; Calabresi, Peter A; Zackowski, Kathleen M

    2017-01-01

    significantly related to corticospinal tract fractional anisotropy (r > 0.26; p < 0.04) and magnetization transfer ratio (r > 0.29; p < 0.03) measures. Although the Expanded Disability Status Scale was highly correlated with walking measures, it was not significantly related to either corticospinal tract fractional anisotropy or magnetization transfer ratio (p > 0.05). Walk velocity was a significant contributor to magnetization transfer ratio (p = 0.006) and fractional anisotropy (p = 0.011) in regression modeling that included both quantitative measures of function and basic clinical information. Quantitative measures of strength and walking are associated with brain corticospinal tract pathology. The addition of these quantitative measures to basic clinical information explains more of the variance in corticospinal tract fractional anisotropy and magnetization transfer ratio than the basic clinical information alone. Outcome measurement for multiple sclerosis clinical trials has been notoriously challenging; the use of quantitative measures of strength and walking along with tract-specific imaging methods may improve our ability to monitor disease change over time, with intervention, and provide needed guidelines for developing more effective targeted rehabilitation strategies.

  17. Precision measurement of the electromagnetic dipole strengths in Be11

    NASA Astrophysics Data System (ADS)

    Kwan, E.; Wu, C. Y.; Summers, N. C.; Hackman, G.; Drake, T. E.; Andreoiu, C.; Ashley, R.; Ball, G. C.; Bender, P. C.; Boston, A. J.; Boston, H. C.; Chester, A.; Close, A.; Cline, D.; Cross, D. S.; Dunlop, R.; Finlay, A.; Garnsworthy, A. B.; Hayes, A. B.; Laffoley, A. T.; Nano, T.; Navrátil, P.; Pearson, C. J.; Pore, J.; Quaglioni, S.; Svensson, C. E.; Starosta, K.; Thompson, I. J.; Voss, P.; Williams, S. J.; Wang, Z. M.

    2014-05-01

    The electromagnetic dipole strength in Be11 between the bound states has been measured using low-energy projectile Coulomb excitation at bombarding energies of 1.73 and 2.09 MeV/nucleon on a Pt196 target. An electric dipole transition probability B(E1;1/2-→1/2+)=0.102(2) e2fm was determined using the semi-classical code Gosia, and a value of 0.098(4) e2fm was determined using the Extended Continuum Discretized Coupled Channels method with the quantum mechanical code FRESCO. These extracted B(E1) values are consistent with the average value determined by a model-dependent analysis of intermediate energy Coulomb excitation measurements and are approximately 14% lower than that determined by a lifetime measurement. The much-improved precisions of 2% and 4% in the measured B(E1) values between the bound states deduced using Gosia and the Extended Continuum Discretized Coupled Channels method, respectively, compared to the previous accuracy of ˜10% will help in our understanding of and better improve the realistic inter-nucleon interactions.

  18. Effects of gamma oryzanol supplementation on anthropometric measurements & muscular strength in healthy males following chronic resistance training.

    PubMed

    Eslami, Saghar; Esa, Norhaizan Mohd; Marandi, Seyed Mohammad; Ghasemi, Gholamali; Eslami, Sepehr

    2014-06-01

    Enhanced muscle strength is seen when resistance exercise is combined with the consumption of nutritional supplements. Although there is a limited number of studies available about the efficacy of gamma oryzanol supplementation with resistance exercise in humans, but its usage as a nutritional supplement for strength is common in athletes. The aim of this study was to determine the effects of gamma oryzanol supplementation during 9-week resistance training on muscular strength and anthropometric measurements of young healthy males. In this double-blind clinical trial, changes of anthropometric measurements and muscular strength were studied after chronic resistance exercise and gamma oryzanol supplementation in 30 healthy volunteers (16 in supplement and 14 in placebo). Each day, gamma oryzanol supplement (600 mg) and placebo (the same amount of lactose) were consumed after training. The participants exercised with 80 per cent 1-Repetition Maximum (1-RM), for one hour and four days/week. Anthropometric measurements and subjects' 1-RM for muscular strength were determined at the commencement and end of the 9-week study. There was no significant difference between the baseline characteristics and target variables at baseline between the two groups. After gamma oryzanol supplementation, there was no significant difference in the means of anthropometric and skin fold measurements between the supplement and placebo groups. However, there were significant differences between the supplement and placebo groups for 1-RM of bench press and leg curl, which showed that gamma oryzanol improved muscle strength following resistance training. Our findings indicated that 600 mg/day gamma oryzanol supplementation during the 9-week resistance training did not change anthropometric and body measurements, but it increased muscular strength in young healthy males. Further, studies need to be done in trained athletes, women, and in patients who suffer from muscular fatigue.

  19. Effects of gamma oryzanol supplementation on anthropometric measurements & muscular strength in healthy males following chronic resistance training

    PubMed Central

    Eslami, Saghar; Esa, Norhaizan Mohd; Marandi, Seyed Mohammad; Ghasemi, Gholamali; Eslami, Sepehr

    2014-01-01

    Background & objectives: Enhanced muscle strength is seen when resistance exercise is combined with the consumption of nutritional supplements. Although there is a limited number of studies available about the efficacy of gamma oryzanol supplementation with resistance exercise in humans, but its usage as a nutritional supplement for strength is common in athletes. The aim of this study was to determine the effects of gamma oryzanol supplementation during 9-week resistance training on muscular strength and anthropometric measurements of young healthy males. Methods: In this double-blind clinical trial, changes of anthropometric measurements and muscular strength were studied after chronic resistance exercise and gamma oryzanol supplementation in 30 healthy volunteers (16 in supplement and 14 in placebo). Each day, gamma oryzanol supplement (600 mg) and placebo (the same amount of lactose) were consumed after training. The participants exercised with 80 per cent 1-Repetition Maximum (1-RM), for one hour and four days/week. Anthropometric measurements and subjects’ 1-RM for muscular strength were determined at the commencement and end of the 9-week study. Results: There was no significant difference between the baseline characteristics and target variables at baseline between the two groups. After gamma oryzanol supplementation, there was no significant difference in the means of anthropometric and skin fold measurements between the supplement and placebo groups. However, there were significant differences between the supplement and placebo groups for 1-RM of bench press and leg curl, which showed that gamma oryzanol improved muscle strength following resistance training. Interpretation & conclusions: Our findings indicated that 600 mg/day gamma oryzanol supplementation during the 9-week resistance training did not change anthropometric and body measurements, but it increased muscular strength in young healthy males. Further, studies need to be done in trained

  20. 47 CFR 73.686 - Field strength measurements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... earth radius, of the largest available scale. (c) Collection of field strength data to determine... measurements in inclement weather or when major weather fronts are moving through the measurement area. (iii....686 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO...

  1. Break-technique handheld dynamometry: relation between angular velocity and strength measurements.

    PubMed

    Burns, Stephen P; Spanier, David E

    2005-07-01

    To determine whether the muscle strength, as measured with break-technique handheld dynamometry (HHD), is dependent on the angular velocity achieved during testing and to compare reliability at different angular velocities. Repeated-measures study. Participants underwent HHD by using make-technique (isometric) and break-technique (eccentric) dynamometry at 3 prespecified angular velocities. Elbow movement was recorded with an electrogoniometer. Inpatient spinal cord injury unit. Convenience sample of 20 persons with tetraplegia with weakness of elbow flexors or extensors. Not applicable. Elbow angular velocity and muscle strength recorded during HHD. With the break technique, angular velocities averaging 15 degrees , 33 degrees , and 55 degrees /s produced 16%, 30%, and 51% greater strength measurements, respectively, than velocities recorded by using the make technique (all P < .006 for comparisons between successive techniques). The intraclass correlation coefficient for intrarater reliability was .89 or greater for all testing techniques. Greater strength is recorded with faster angular velocities during HHD. Differences in angular velocity may explain the wide range previously reported for break- versus make-technique strength measurements. Variation in angular velocity is a potential source of variability in serial HHD strength measurements, and for this reason the make technique may be preferable.

  2. Sparse targets in hydroacoustic surveys: Balancing quantity and quality of in situ target strength data

    USGS Publications Warehouse

    DuFour, Mark R.; Mayer, Christine M.; Kocovsky, Patrick; Qian, Song; Warner, David M.; Kraus, Richard T.; Vandergoot, Christopher

    2017-01-01

    Hydroacoustic sampling of low-density fish in shallow water can lead to low sample sizes of naturally variable target strength (TS) estimates, resulting in both sparse and variable data. Increasing maximum beam compensation (BC) beyond conventional values (i.e., 3 dB beam width) can recover more targets during data analysis; however, data quality decreases near the acoustic beam edges. We identified the optimal balance between data quantity and quality with increasing BC using a standard sphere calibration, and we quantified the effect of BC on fish track variability, size structure, and density estimates of Lake Erie walleye (Sander vitreus). Standard sphere mean TS estimates were consistent with theoretical values (−39.6 dB) up to 18-dB BC, while estimates decreased at greater BC values. Natural sources (i.e., residual and mean TS) dominated total fish track variation, while contributions from measurement related error (i.e., number of single echo detections (SEDs) and BC) were proportionally low. Increasing BC led to more fish encounters and SEDs per fish, while stability in size structure and density were observed at intermediate values (e.g., 18 dB). Detection of medium to large fish (i.e., age-2+ walleye) benefited most from increasing BC, as proportional changes in size structure and density were greatest in these size categories. Therefore, when TS data are sparse and variable, increasing BC to an optimal value (here 18 dB) will maximize the TS data quantity while limiting lower-quality data near the beam edges.

  3. ELF Field Strength Measurements Made in Connecticut During 1974

    DTIC Science & Technology

    1975-10-01

    Ionospheric Phenomena on Extremely Low Frequency ( ELF ) Propagation," IEEE Transactions on Communications , vol. COM-22, no. 4, 1974, pp. 484-492...34f" ""WW" I I W»*-«P ’^ AD-A016 795 ELF FIELD STRENGTH MEASUREMENTS MADE IN CONNECTICUT DURING 1974 Peter R. Bannister...Report 4927 CD rH O ELF Field Strength Measurements Made In Connecticut During 1974 PETER R. BANNISTER FREDERICK J. WILLIAMS Submarin

  4. A Measure of Perceived Argument Strength: Reliability and Validity

    PubMed Central

    Zhao, Xiaoquan; Strasser, Andrew; Cappella, Joseph N.; Lerman, Caryn; Fishbein, Martin

    2014-01-01

    Studies of the content of persuasive messages in which the central arguments of the message are scrutinized have traditionally relied on the technique of thought-listing to assess argument strength. Although the validity of the thought-listing procedure is well documented, its utility can be limited in situations involving non-adult populations and sensitive topics. In this paper we present a self-reported scale that can be used to assess perceived argument strength in contexts where thought-listing may be less appropriate. This scale taps into perceived argument strength from multiple points of view, including but also extending beyond the potential of the argument to elicit positive and negative thoughts. Reliability and validity of this scale were assessed in health communication contexts involving anti-drug PSAs directed at adolescents and anti-smoking PSAs targeting adults. Evidence of convergence between this scale and the thought-listing technique was also obtained using the classical comprehensive exam arguments. PMID:25568663

  5. 47 CFR 2.1053 - Measurements required: Field strength of spurious radiation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Measurements required: Field strength of spurious radiation. 2.1053 Section 2.1053 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL... Procedures Certification § 2.1053 Measurements required: Field strength of spurious radiation. (a...

  6. 47 CFR 2.1053 - Measurements required: Field strength of spurious radiation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Measurements required: Field strength of spurious radiation. 2.1053 Section 2.1053 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL... Procedures Certification § 2.1053 Measurements required: Field strength of spurious radiation. (a...

  7. 47 CFR 2.1053 - Measurements required: Field strength of spurious radiation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Measurements required: Field strength of spurious radiation. 2.1053 Section 2.1053 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL... Procedures Certification § 2.1053 Measurements required: Field strength of spurious radiation. (a...

  8. Scale-dependent measurements of meteorite strength: Implications for asteroid fragmentation

    NASA Astrophysics Data System (ADS)

    Cotto-Figueroa, Desireé; Asphaug, Erik; Garvie, Laurence A. J.; Rai, Ashwin; Johnston, Joel; Borkowski, Luke; Datta, Siddhant; Chattopadhyay, Aditi; Morris, Melissa A.

    2016-10-01

    Measuring the strengths of asteroidal materials is important for developing mitigation strategies for potential Earth impactors and for understanding properties of in situ materials on asteroids during human and robotic exploration. Studies of asteroid disruption and fragmentation have typically used the strengths determined from terrestrial analog materials, although questions have been raised regarding the suitability of these materials. The few published measurements of meteorite strength are typically significantly greater than those estimated from the stratospheric breakup of meter-sized meteoroids. Given the paucity of relevant strength data, the scale-varying strength properties of meteoritic and asteroidal materials are poorly constrained. Based on our uniaxial failure studies of centimeter-sized cubes of a carbonaceous and ordinary chondrite, we develop the first Weibull failure distribution analysis of meteorites. This Weibull distribution projected to meter scales, overlaps the strengths determined from asteroidal airbursts and can be used to predict properties of to the 100 m scale. In addition, our analysis shows that meter-scale boulders on asteroids are significantly weaker than small pieces of meteorites, while large meteorites surviving on Earth are selected by attrition. Further, the common use of terrestrial analog materials to predict scale-dependent strength properties significantly overestimates the strength of meter-sized asteroidal materials and therefore is unlikely well suited for the modeling of asteroid disruption and fragmentation. Given the strength scale-dependence determined for carbonaceous and ordinary chondrite meteorites, our results suggest that boulders of similar composition on asteroids will have compressive strengths significantly less than typical terrestrial rocks.

  9. EXPERIMENTALLY MEASURED RADIATIVE LIFETIMES AND OSCILLATOR STRENGTHS IN NEUTRAL VANADIUM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holmes, C. E.; Pickering, J. C.; Ruffoni, M. P.

    2016-06-01

    We report a new study of the V i atom using a combination of time-resolved laser-induced fluorescence and Fourier transform spectroscopy that contains newly measured radiative lifetimes for 25 levels between 24,648 cm{sup −1} and 37,518 cm{sup −1} and oscillator strengths for 208 lines between 3040 and 20000 Å from 39 upper energy levels. Thirteen of these oscillator strengths have not been reported previously. This work was conducted independently of the recent studies of neutral vanadium lifetimes and oscillator strengths carried out by Den Hartog et al. and Lawler et al., and thus serves as a means to verify thosemore » measurements. Where our data overlap with their data, we generally find extremely good agreement in both level lifetimes and oscillator strengths. However, we also find evidence that Lawler et al. have systematically underestimated oscillator strengths for lines in the region of 9000 ± 100 Å. We suggest a correction of 0.18 ± 0.03 dex for these values to bring them into agreement with our results and those of Whaling et al. We also report new measurements of hyperfine structure splitting factors for three odd levels of V i lying between 24,700 and 28,400 cm{sup −1}.« less

  10. Myotonometry as a Surrogate Measure of Muscle Strength

    NASA Technical Reports Server (NTRS)

    Ang, B. S.; Feeback, D. L.; Leonard, C. T.; Sykes, J.; Kruger, E.; Clarke, M. S. F.

    2007-01-01

    Space flight-induced muscle atrophy/neuromuscular degradation and the consequent decrements in crew-member performance are of increasing concern as mission duration lengthens, and planetary exploration after extended space flight is planned. Pre- to post-flight strength measures have demonstrated that specific countermeasures, such as resistive exercise, are effective at countering microgravity-induced muscle atrophy and preventing decrements in muscle strength. However, in-flight assessment/monitoring of exercise countermeasure effectiveness will be essential during exploration class missions due to their duration. The ability to modify an exercise countermeasure prescription based on such real-time information will allow each individual crew member to perform the optimal amount and type of exercise countermeasure to maintain performance. In addition, such measures can be used to determine if a crew member is physically capable of performing a particular mission-related task during exploration class missions. The challenges faced in acquiring such data are those common to all space operations, namely the requirement for light-weight, low power, mechanically reliable technologies that make valid measurements in microgravity, in this case of muscle strength/neuromuscular function. Here we describe a simple, light-weight, low power, non-invasive device, known as the Myotonometer, that measures tissue stiffness as an indirect measure of muscle contractile state and muscle force production. Repeat myotonometer measurements made at the same location on the surface of the rectis femoris muscle (as determined using a 3D locator device, SEM plus or minus 0.34 mm) were shown to be reproducible over time at both maximal voluntary contraction (MVC) and at rest in a total of 17 sedentary subjects assessed three times over a period of seven days. In addition, graded voluntary isometric force production (i.e. 20%, 40%, 60%, 80% & 100% of MVC) during knee extension was shown to

  11. Measuring Soil Moisture using the Signal Strength of Buried Bluetooth Devices.

    NASA Astrophysics Data System (ADS)

    Hut, R.; Campbell, C. S.

    2015-12-01

    A low power bluetooth Low Energy (BLE) device is burried 20cm into the soil and a smartphone is placed on top of the soil to test if bluetooth signal strength can be related to soil moisture. The smartphone continuesly records and stores bluetooth signal strength of the device. The soil is artifcially wetted and drained. Results show a relation between BLE signal strength and soil moisture that could be used to measure soil moisture using these off-the-shelf consumer electronics. This opens the possibily to develop sensors that can be buried into the soil, possibly below the plow-line. These sensors can measure local parameters such as electric conductivity, ph, pressure, etc. Readings would be uploaded to a device on the surface using BLE. The signal strength of this BLE would be an (additional) measurement of soil moisture.

  12. An improved device to measure cottonseed strength

    USDA-ARS?s Scientific Manuscript database

    During processing, seeds of cotton cultivars with fragile seeds often break and produce seed coat fragments that can cause processing problems at textile mills. A cottonseed shear tester, previously developed to measure cottonseed strength, was modified with enhancements to the drive system to provi...

  13. Strength Measurements in Acute Hamstring Injuries: Intertester Reliability and Prognostic Value of Handheld Dynamometry.

    PubMed

    Reurink, Gustaaf; Goudswaard, Gert Jan; Moen, Maarten H; Tol, Johannes L; Verhaar, Jan A N; Weir, Adam

    2016-08-01

    Study Design Cohort study, repeated measures. Background Although hamstring strength measurements are used for assessing prognosis and monitoring recovery after hamstring injury, their actual clinical relevance has not been established. Handheld dynamometry (HHD) is a commonly used method of measuring muscle strength. The reliability of HHD has not been determined in athletes with acute hamstring injuries. Objectives To determine the intertester reliability and the prognostic value of hamstring HHD strength measurement in acute hamstring injuries. Methods We measured knee flexion strength with HHD in 75 athletes at 2 visits, at baseline (within 5 days of hamstring injury) and follow-up (5 to 7 days after the baseline measurement). We assessed isometric hamstring strength in 15° and 90° of knee flexion. Reliability analysis testing was performed by 2 testers independently at the follow-up visit. We recorded the time needed to return to play (RTP) up to 6 months following baseline. Results The intraclass correlation coefficients of the strength measurements in injured hamstrings were between 0.75 and 0.83. There was a statistically significant but weak correlation between the time to RTP and the strength deficit at 15° of knee flexion measured at baseline (Spearman r = 0.25, P = .045) and at the follow-up visit (Spearman r = 0.26, P = .034). Up to 7% of the variance in time to RTP is explained by this strength deficit. None of the other strength variables were significantly correlated with time to RTP. Conclusion Hamstring strength can be reliably measured with HHD in athletes with acute hamstring injuries. The prognostic value of strength measurements is limited, as there is only a weak association between the time to RTP and hamstring strength deficit after acute injury. Level of Evidence Prognosis, level 4. J Orthop Sports Phys Ther 2016;46(8):689-696. Epub 12 May 2016. doi:10.2519/jospt.2016.6363.

  14. Normative Measurements of Grip and Pinch Strengths of 21st Century Korean Population

    PubMed Central

    Shim, Jin Hee; Kim, Jin Soo; Lee, Dong Chul; Ki, Sae Hwi; Yang, Jae Won; Jeon, Man Kyung; Lee, Sang Myung

    2013-01-01

    Background Measuring grip and pinch strength is an important part of hand injury evaluation. Currently, there are no standardized values of normal grip and pinch strength among the Korean population, and lack of such data prevents objective evaluation of post-surgical recovery in strength. This study was designed to establish the normal values of grip and pinch strength among the healthy Korean population and to identify any dependent variables affecting grip and pinch strength. Methods A cross-sectional study was carried out. The inclusion criterion was being a healthy Korean person without a previous history of hand trauma. The grip strength was measured using a Jamar dynamometer. Pulp and key pinch strength were measured with a hydraulic pinch gauge. Intra-individual and inter-individual variations in these variables were analyzed in a standardized statistical manner. Results There were a total of 336 healthy participants between 13 and 77 years of age. As would be expected in any given population, the mean grip and pinch strength was greater in the right hand than the left. Male participants (137) showed mean strengths greater than female participants (199) when adjusted for age. Among the male participants, anthropometric variables correlated positively with grip strength, but no such correlations were identifiable in female participants in a statistically significant way. Conclusions Objective measurements of hand strength are an important component of hand injury evaluation, and population-specific normative data are essential for clinical and research purposes. This study reports updated normative hand strengths of the South Korean population in the 21st century. PMID:23362480

  15. Association of balance, strength, and power measures in young adults.

    PubMed

    Muehlbauer, Thomas; Gollhofer, Albert; Granacher, Urs

    2013-03-01

    The purpose of this study was to investigate the relationship between variables of static/dynamic balance, isometric strength, and power. Twenty-seven young healthy adults (mean age: 23 ± 4 years) performed measurements of static (unperturbed)/dynamic (perturbed) balance, isometric strength (i.e., maximal isometric torque [MIT]; rate of torque development [RTD] of the plantar flexor), and power (i.e., countermovement jump [CMJ] height and power). No significant associations were found between variables of static and dynamic balance (r = -0.090 to +0.329, p > 0.05) and between measures of static/dynamic balance and isometric strength (r = +0.041 to +0.387, p > 0.05) and static/dynamic balance and power (r = -0.076 to +0.218, p > 0.05). Significant positive correlations (r) were detected between variables of power and isometric strength ranging from +0.458 to +0.689 (p < 0.05). Furthermore, simple regression analyses revealed that a 10% increase in mean CMJ height (4.1 cm) was associated with 22.9 N·m and 128.4 N·m·s better MIT and RTD, respectively. The nonsignificant correlation between static and dynamic balance measures and between static/dynamic balance, isometric strength, and power variables implies that these capacities may be independent of each other and may have to be tested and trained complementarily.

  16. 47 CFR 73.61 - AM directional antenna field strength measurements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false AM directional antenna field strength... RADIO SERVICES RADIO BROADCAST SERVICES AM Broadcast Stations § 73.61 AM directional antenna field strength measurements. (a) Each AM station using a directional antenna with monitoring point locations...

  17. 47 CFR 73.61 - AM directional antenna field strength measurements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false AM directional antenna field strength... RADIO SERVICES RADIO BROADCAST SERVICES AM Broadcast Stations § 73.61 AM directional antenna field strength measurements. (a) Each AM station using a directional antenna with monitoring point locations...

  18. 47 CFR 73.61 - AM directional antenna field strength measurements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 4 2013-10-01 2013-10-01 false AM directional antenna field strength... RADIO SERVICES RADIO BROADCAST SERVICES AM Broadcast Stations § 73.61 AM directional antenna field strength measurements. (a) Each AM station using a directional antenna with monitoring point locations...

  19. 47 CFR 73.61 - AM directional antenna field strength measurements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false AM directional antenna field strength... RADIO SERVICES RADIO BROADCAST SERVICES AM Broadcast Stations § 73.61 AM directional antenna field strength measurements. (a) Each AM station using a directional antenna with monitoring point locations...

  20. 47 CFR 73.61 - AM directional antenna field strength measurements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false AM directional antenna field strength... RADIO SERVICES RADIO BROADCAST SERVICES AM Broadcast Stations § 73.61 AM directional antenna field strength measurements. (a) Each AM station using a directional antenna with monitoring point locations...

  1. Effects of trunk stability on isometric knee extension muscle strength measurement while sitting.

    PubMed

    Hirano, Masahiro; Gomi, Masahiro; Katoh, Munenori

    2016-09-01

    [Purpose] This study aimed to investigate the effect of trunk stability on isometric knee extension muscle strength measurement while sitting by performing simultaneous measurements with a handheld dynamometer (HHD) and an isokinetic dynamometer (IKD) in the same seated condition. [Subjects and Methods] The subjects were 30 healthy volunteers. Isometric knee extension muscle strength was simultaneously measured with a HHD and an IKD by using an IKD-specific chair. The measurement was performed twice. Measurement instrument variables and the number of measurements were examined by using the analysis of variance and correlation tests. [Results] The measurement instrument variables and the number of measurements were not significantly different. The correlation coefficients between the HHD and IKD measurements were ≥0.96. [Conclusion] Isometric knee extension muscle strength measurement using the HHD in the sitting position resulted in a lower value than that using the IKD, presumably because of the effect of trunk stability on the measurement. In the same seated posture with trunk stability, no significant difference in measurement values was observed between the HHD and IKD. The present findings suggest that trunk stability while seated during isometric knee extension muscle strength measurement influenced the HHD measurement.

  2. RELIABILITY OF ANKLE-FOOT MORPHOLOGY, MOBILITY, STRENGTH, AND MOTOR PERFORMANCE MEASURES.

    PubMed

    Fraser, John J; Koldenhoven, Rachel M; Saliba, Susan A; Hertel, Jay

    2017-12-01

    Assessment of foot posture, morphology, intersegmental mobility, strength and motor control of the ankle-foot complex are commonly used clinically, but measurement properties of many assessments are unclear. To determine test-retest and inter-rater reliability, standard error of measurement, and minimal detectable change of morphology, joint excursion and play, strength, and motor control of the ankle-foot complex. Reliability study. 24 healthy, recreationally-active young adults without history of ankle-foot injury were assessed by two clinicians on two occasions, three to ten days apart. Measurement properties were assessed for foot morphology (foot posture index, total and truncated length, width, arch height), joint excursion (weight-bearing dorsiflexion, rearfoot and hallux goniometry, forefoot inclinometry, 1 st metatarsal displacement) and joint play, strength (handheld dynamometry), and motor control rating during intrinsic foot muscle (IFM) exercises. Clinician order was randomized using a Latin Square. The clinicians performed independent examinations and did not confer on the findings for the duration of the study. Test-retest and inter-tester reliability and agreement was assessed using intraclass correlation coefficients (ICC 2,k ) and weighted kappa ( K w ). Test-retest reliability ICC were as follows: morphology: .80-1.00, joint excursion: .58-.97, joint play: -.67-.84, strength: .67-.92, IFM motor rating: K W -.01-.71. Inter-rater reliability ICC were as follows: morphology: .81-1.00, joint excursion: .32-.97, joint play: -1.06-1.00, strength: .53-.90, and IFM motor rating: K w .02-.56. Measures of ankle-foot posture, morphology, joint excursion, and strength demonstrated fair to excellent test-retest and inter-rater reliability. Test-retest reliability for rating of perceived difficulty and motor performance was good to excellent for short-foot, toe-spread-out, and hallux exercises and poor to fair for lesser toe extension. Joint play measures had

  3. Reliability and Validity of Finger Strength and Endurance Measurements in Rock Climbing

    ERIC Educational Resources Information Center

    Michailov, Michail Lubomirov; Baláš, Jirí; Tanev, Stoyan Kolev; Andonov, Hristo Stoyanov; Kodejška, Jan; Brown, Lee

    2018-01-01

    Purpose: An advanced system for the assessment of climbing-specific performance was developed and used to: (a) investigate the effect of arm fixation (AF) on construct validity evidence and reliability of climbing-specific finger-strength measurement; (b) assess reliability of finger-strength and endurance measurements; and (c) evaluate the…

  4. Low-Frequency Surface Backscattering Strengths Measured in the Critical Sea Test Experiments

    DTIC Science & Technology

    2017-01-19

    Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/7160--17-9702 Low-Frequency Surface Backscattering Strengths Measured in the Critical Sea ...LIMITATION OF ABSTRACT Low-Frequency Surface Backscattering Strengths Measured in the Critical Sea Test Experiments Roger C. Gauss1 and Joseph M...significantly- updated results from 55 broadband SUS SSS measurements in 6 Critical Sea Test (CST) experiments. Since the time of the previously

  5. Correlation of bond strength with surface roughness using a new roughness measurement technique.

    PubMed

    Winkler, M M; Moore, B K

    1994-07-01

    The correlation between shear bond strength and surface roughness was investigated using new surface measurement methods. Bonding agents and associated resin composites were applied to set amalgam after mechanically roughening its surface. Surface treatments were noe (as set against glass), 80 grit, and 600 grit abrasive paper. Surface roughness (R(a) as measured parallel and perpendicular (+) to the direction of the polishing scratches and true profile length were measured. A knife-edge was applied (rate = 2.54 mm/min) at the bonding agent/amalgam interface of each sample until failure. Coefficients of determination for mean bond strength vs either roughness (R(a), of profile length were significantly higher for measurements in parallel directions than for those measurements in (+) directions. The shear bond strength to set amalgam for a PENTA-containing adhesives system (L.D. Caulk Division) was not significantly different from that of a PENTA-free adhesive (3M Dental Products Division), even though PENTA has been reported to increase bond strength to nonprecious metals. The shear bond strength of resin composite to amalgam is correlated to surface roughness when it is measured parallel to the polishing scratches. This correlation is significantly lower when surface roughness is measured in the typical manner, perpendicular to the polishing scratches.

  6. Measurement of interface strength by a laser spallation technique

    NASA Astrophysics Data System (ADS)

    Gupta, V.; Argon, A. S.; Parks, D. M.; Cornie, J. A.

    A LASER spallation experiment has been developed to measure the strength of planar interfaces between a substrate and a thin coating (in the thickness range of 0.3-3 μm). In this technique a laser pulse of a high enough energy and a pre-determined duration is converted into a pressure pulse of a critical amplitude and width that is sent through the substrate toward the free surface with the coating. The reflected tensile wave from the free surface of the coating pries-off the coating. The critical stress amplitude that accomplishes the removal of the coating is determined from a computer simulation of the process. The simulation itself is verified by means of a piezo-electric crystal probe that is capable of mapping out the profile of the stress pulse generated by the laser pulse. Interface strength values ranging from 3.7 to 10.5 GPa were determined for the Si/SiC system. For the interfaces between pyrolytic graphite and SiC coatings an average strength of 7.2 GPA was measured, while the corresponding interface strength between a Pitch-55 type ribbon with a fiber-like morphology and SiC coatings was found to be 0.23 GPa. Intrinsic strengths of SiC coatings and Si crystal were also determined using this technique. These were, on the average, 8.6 GPa for Si crystals and 11.9 GPa for a SiC coating. Furthermore, the potential of the laser technique to determine the interface toughness was also demonstrated, provided well-characterizable flaws can be planted on the interface.

  7. Planetary and Primitive Object Strength Measurement and Sampling Apparatus

    NASA Technical Reports Server (NTRS)

    Ahrens, Thomas J.

    1995-01-01

    Support is requested for continuation of a program of dynamic impact (harpoon) coring of planetary, comet, or asteroid surface materials. We have previously demonstrated that good quality cores are obtainable for planetary materials with compressive strengths less than 200 MPa. Since the dynamics of penetration are observable on a Discovery class spacecraft, which images the sampling operation, these data can be used with a model developed under this project, to measure in-situ strength and frictional strength of the crust of the object. During the last year we have developed a detailed analytic model of penetrator mechanics. Progress is reported for the solid penetrators experiments, the CIT penetrator model, and the impact spall sampling apparatus.

  8. Targeting cancer’s weaknesses (not its strengths): Therapeutic strategies suggested by the atavistic model

    PubMed Central

    Lineweaver, Charles H.; Davies, Paul C.W.; Vincent, Mark D.

    2014-01-01

    In the atavistic model of cancer progression, tumor cell dedifferentiation is interpreted as a reversion to phylogenetically earlier capabilities. The more recently evolved capabilities are compromised first during cancer progression. This suggests a therapeutic strategy for targeting cancer: design challenges to cancer that can only be met by the recently evolved capabilities no longer functional in cancer cells. We describe several examples of this target-the-weakness strategy. Our most detailed example involves the immune system. The absence of adaptive immunity in immunosuppressed tumor environments is an irreversible weakness of cancer that can be exploited by creating a challenge that only the presence of adaptive immunity can meet. This leaves tumor cells more vulnerable than healthy tissue to pathogenic attack. Such a target-the-weakness therapeutic strategy has broad applications, and contrasts with current therapies that target the main strength of cancer: cell proliferation. PMID:25043755

  9. Precision Measurements of the B(E1) Strengths in 11Be

    NASA Astrophysics Data System (ADS)

    Kwan, E.; Wu, C. Y.; Summers, N. C.; Hackman, G.; Drake, T. E.; Andreoiu, C.; Ashley, R.; Ball, G. C.; Bender, P. C.; Boston, A. J.; Boston, H. C.; Chester, A.; Close, A.; Cline, D.; Cross, D. S.; Dunlop, R.; Finley, A.; Garnsworthy, A.; Hayes, A. B.; Laffoley, A. T.; Nano, T.; Navrátil, P.; Pearson, C. J.; Pore, J.; Starosta, K.; Thompson, I. J.; Voss, P.; Williams, S. J.; Wang, Z. M.

    2014-09-01

    The electromagnetic transition strength between the two bound states were measured in the one-neutron halo nucleus 11Be from Coulomb excitation on 196Pt at projectile energies of 1.727 and 2.086 MeV/nucleon at TRIUMF. A B(E1) strength of 0.102(2) e2fm2, deduced from the forward-scattering data, is consistent with previous Coulomb excitation measurements at intermediate projectile energies with a model-dependent analysis.

  10. Tensile and shear methods for measuring strength of bilayer tablets.

    PubMed

    Chang, Shao-Yu; Li, Jian-Xin; Sun, Changquan Calvin

    2017-05-15

    Both shear and tensile measurement methods have been used to quantify interfacial bonding strength of bilayer tablets. The shear method is more convenient to perform, but reproducible strength data requires careful control of the placement of tablet and contact point for shear force application. Moreover, data obtained from the shear method depend on the orientation of the bilayer tablet. Although more time-consuming to perform, the tensile method yields data that are straightforward to interpret. Thus, the tensile method is preferred in fundamental bilayer tableting research to minimize ambiguity in data interpretation. Using both shear and tensile methods, we measured the mechanical strength of bilayer tablets made of several different layer combinations of lactose and microcrystalline cellulose. We observed a good correlation between strength obtained by the tensile method and carefully conducted shear method. This suggests that the shear method may be used for routine quality test of bilayer tablets during manufacturing because of its speed and convenience, provided a protocol for careful control of the placement of the tablet interface, tablet orientation, and blade is implemented. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Factor Structure of Character Strengths in Youth: Consistency across Ages and Measures

    ERIC Educational Resources Information Center

    McGrath, Robert E.; Walker, David Ian

    2016-01-01

    The VIA Classification of Strengths and Virtues attempts to provide a comprehensive model of character based on 24 character strengths. The present study is the largest study to date exploring the structure of the 24 strengths in youth. One sample (N = 23,850) completed the VIA-Youth, a teen measure of the VIA Classification. Based on a random…

  12. On Target Localization Using Combined RSS and AoA Measurements

    PubMed Central

    Beko, Marko; Dinis, Rui

    2018-01-01

    This work revises existing solutions for a problem of target localization in wireless sensor networks (WSNs), utilizing integrated measurements, namely received signal strength (RSS) and angle of arrival (AoA). The problem of RSS/AoA-based target localization became very popular in the research community recently, owing to its great applicability potential and relatively low implementation cost. Therefore, here, a comprehensive study of the state-of-the-art (SoA) solutions and their detailed analysis is presented. The beginning of this work starts by considering the SoA approaches based on convex relaxation techniques (more computationally complex in general), and it goes through other (less computationally complex) approaches, as well, such as the ones based on the generalized trust region sub-problems framework and linear least squares. Furthermore, a detailed analysis of the computational complexity of each solution is reviewed. Furthermore, an extensive set of simulation results is presented. Finally, the main conclusions are summarized, and a set of future aspects and trends that might be interesting for future research in this area is identified. PMID:29671832

  13. Probing microbubble targeting with atomic force microscopy.

    PubMed

    Sboros, V; Glynos, E; Ross, J A; Moran, C M; Pye, S D; Butler, M; McDicken, W N; Brown, S B; Koutsos, V

    2010-10-01

    Microbubble science is expanding beyond ultrasound imaging applications to biological targeting and drug/gene delivery. The characteristics of molecular targeting should be tested by a measurement system that can assess targeting efficacy and strength. Atomic force microscopy (AFM) is capable of piconewton force resolution, and is reported to measure the strength of single hydrogen bonds. An in-house targeted microbubble modified using the biotin-avidin chemistry and the CD31 antibody was used to probe cultures of Sk-Hep1 hepatic endothelial cells. We report that the targeted microbubbles provide a single distribution of adhesion forces with a median of 93pN. This interaction is assigned to the CD31 antibody-antigen unbinding event. Information on the distances between the interaction forces was obtained and could be important for future microbubble fabrication. In conclusion, the capability of single microbubbles to target cell lines was shown to be feasible with AFM.

  14. 47 CFR 73.153 - Field strength measurements in support of applications or evidence at hearings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Field strength measurements in support of... (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES AM Broadcast Stations § 73.153 Field strength..., groundwave field strength measurements will take precedence over theoretical values, provided such...

  15. 47 CFR 73.153 - Field strength measurements in support of applications or evidence at hearings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Field strength measurements in support of... (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES AM Broadcast Stations § 73.153 Field strength..., groundwave field strength measurements will take precedence over theoretical values, provided such...

  16. Quantification of bone strength by intraoperative torque measurement: a technical note.

    PubMed

    Suhm, Norbert; Haenni, Markus; Schwyn, Ronald; Hirschmann, Michael; Müller, Andreas Marc

    2008-06-01

    Bone strength describes the resistance of bone against mechanical failure. Bone strength depends on both the amount of bone and the bone's quality, and the bone strength may be looked upon as a relevant parameter to judge an osteosynthesis' stability. Information about bone strength was barely available intraoperatively in the past. The previous work of our group reported on development and laboratory evaluation of mechanical torque measurement as a method for the intraoperative quantification of bone strength. With the clinical series presented here we intend to verify that the im gesamten Text DensiProbe instrumentation for intraoperative torque measurement and the related measurement method are eligible for intraoperative use based on the following criteria: application of the method may not create complications, the measurement can be performed by the surgeon himself and may only cause a limited increase in the procedure time. From December 2006 until May 2007 ten patients with a pertrochanteric femoral fracture or a lateral femoral neck fracture eligible for stabilization with DHS were included in the study after having received informed consent. Any medication and comorbidity that might have influenced bone quality or bone mineral density (BMD) in these patients was documented. Bone strength was intraoperatively measured with DensiProbe. Complications that were obviously related with torque measurement were documented as well as any deviation from the suggested procedure; 6 and 12 weeks postoperative follow-up included clinical and radiological examination. The time required for torque measurement, the overall operating time and the number of persons present in the operating room were protocolled. BMD values of the contralateral femoral neck were postoperatively assessed by dual energy X-ray absorptiometry (DEXA) and compared to intraoperative peak torque values measured by DensiProbe. No major complication was observed during intraoperative application of

  17. Optical Phase Measurements of Disorder Strength Link Microstructure to Cell Stiffness.

    PubMed

    Eldridge, Will J; Steelman, Zachary A; Loomis, Brianna; Wax, Adam

    2017-02-28

    There have been sustained efforts on the part of cell biologists to understand the mechanisms by which cells respond to mechanical stimuli. To this end, many rheological tools have been developed to characterize cellular stiffness. However, measurement of cellular viscoelastic properties has been limited in scope by the nature of most microrheological methods, which require direct mechanical contact, applied at the single-cell level. In this article, we describe, to our knowledge, a new analysis approach for quantitative phase imaging that relates refractive index variance to disorder strength, a parameter that is linked to cell stiffness. Significantly, both disorder strength and cell stiffness are measured with the same phase imaging system, presenting a unique alternative for label-free, noncontact, single-shot imaging of cellular rheologic properties. To demonstrate the potential applicability of the technique, we measure phase disorder strength and shear stiffness across five cellular populations with varying mechanical properties and demonstrate an inverse relationship between these two parameters. The existence of this relationship suggests that predictions of cell mechanical properties can be obtained from examining the disorder strength of cell structure using this, to our knowledge, novel, noncontact technique. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  18. Optoelectronic System Measures Distances to Multiple Targets

    NASA Technical Reports Server (NTRS)

    Liebe, Carl Christian; Abramovici, Alexander; Bartman, Randall; Chapsky, Jacob; Schmalz, John; Coste, Keith; Litty, Edward; Lam, Raymond; Jerebets, Sergei

    2007-01-01

    An optoelectronic metrology apparatus now at the laboratory-prototype stage of development is intended to repeatedly determine distances of as much as several hundred meters, at submillimeter accuracy, to multiple targets in rapid succession. The underlying concept of optoelectronic apparatuses that can measure distances to targets is not new; such apparatuses are commonly used in general surveying and machining. However, until now such apparatuses have been, variously, constrained to (1) a single target or (2) multiple targets with a low update rate and a requirement for some a priori knowledge of target geometry. When fully developed, the present apparatus would enable measurement of distances to more than 50 targets at an update rate greater than 10 Hz, without a requirement for a priori knowledge of target geometry. The apparatus (see figure) includes a laser ranging unit (LRU) that includes an electronic camera (photo receiver), the field of view of which contains all relevant targets. Each target, mounted at a fiducial position on an object of interest, consists of a small lens at the output end of an optical fiber that extends from the object of interest back to the LRU. For each target and its optical fiber, there is a dedicated laser that is used to illuminate the target via the optical fiber. The targets are illuminated, one at a time, with laser light that is modulated at a frequency of 10.01 MHz. The modulated laser light is emitted by the target, from where it returns to the camera (photodetector), where it is detected. Both the outgoing and incoming 10.01-MHz laser signals are mixed with a 10-MHz local-oscillator to obtain beat notes at 10 kHz, and the difference between the phases of the beat notes is measured by a phase meter. This phase difference serves as a measure of the total length of the path traveled by light going out through the optical fiber and returning to the camera (photodetector) through free space. Because the portion of the path

  19. Validity Evidence for the Measurement of the Strength of Motivation for Medical School

    ERIC Educational Resources Information Center

    Kusurkar, Rashmi; Croiset, Gerda; Kruitwagen, Cas; ten Cate, Olle

    2011-01-01

    The Strength of Motivation for Medical School (SMMS) questionnaire is designed to determine the strength of motivation of students particularly for medical study. This research was performed to establish the validity evidence for measuring strength of motivation for medical school. Internal structure and relations to other variables were used as…

  20. Alternative Penetrometers to Measure the Near Surface Strength of Soft Seafloor Soils

    DTIC Science & Technology

    2011-09-30

    penetrometer (CPT), standard ball penetrometer (BPT), mini-ball penetrometer (mBPT) and a shear vane ( VST ). The CPT and BPT measure electronically a...The VST records the undrained shear strength of the soil at discreet depths. In addition, Shelby tube samples were collected for triaxial and...benchmark strengths from the VST and triaxial/simple shear tests. Thus far, the VST strengths have compared favorably with the results. Results from the

  1. Target thrust measurement for applied-field magnetoplasmadynamic thruster

    NASA Astrophysics Data System (ADS)

    Wang, B.; Yang, W.; Tang, H.; Li, Z.; Kitaeva, A.; Chen, Z.; Cao, J.; Herdrich, G.; Zhang, K.

    2018-07-01

    In this paper, we present a flat target thrust stand which is designed to measure the thrust of a steady-state applied-field magnetoplasmadynamic thruster (AF-MPDT). In our experiments we varied target-thruster distances and target size to analyze their influence on the target thrust measurement results. The obtained thrust-distance curves increase to local maximum and then decreases with the increasing distance, which means that the plume of the AF-MPDT can still accelerate outside the thruster exit. The peak positions are related to the target sizes: larger targets can make the peak positions further from the thruster and decrease the measurement errors. To further improve the reliability of measurement results, a thermal equilibrium assumption combined with Knudsen’s cosine law is adapted to analyze the error caused by the back stream of plume particles. Under the assumption, the error caused by particle backflow is no more than 3.6% and the largest difference between the measured thrust and the theoretical thrust is 14%. Moreover, it was verified that target thrust measurement can disturb the working of the AF-MPD thruster, and the influence on the thrust measurement result is no more than 1% in our experiment.

  2. Experience of the fibrotest for measuring cotton fiber length and strength properties

    USDA-ARS?s Scientific Manuscript database

    The Fibrotest is a device developed by Textechno for measuring cotton fiber length and strength properties. The Fibrotest provides abundant information, including more than 20 length and strength parameters in absolute and relative modes, and displays fibrogram, load-elongation curve, and fiber bea...

  3. NemaFlex: a microfluidics-based technology for standardized measurement of muscular strength of C. elegans.

    PubMed

    Rahman, Mizanur; Hewitt, Jennifer E; Van-Bussel, Frank; Edwards, Hunter; Blawzdziewicz, Jerzy; Szewczyk, Nathaniel J; Driscoll, Monica; Vanapalli, Siva A

    2018-06-12

    Muscle strength is a functional measure of quality of life in humans. Declines in muscle strength are manifested in diseases as well as during inactivity, aging, and space travel. With conserved muscle biology, the simple genetic model C. elegans is a high throughput platform in which to identify molecular mechanisms causing muscle strength loss and to develop interventions based on diet, exercise, and drugs. In the clinic, standardized strength measures are essential to quantitate changes in patients; however, analogous standards have not been recapitulated in the C. elegans model since force generation fluctuates based on animal behavior and locomotion. Here, we report a microfluidics-based system for strength measurement that we call 'NemaFlex', based on pillar deflection as the nematode crawls through a forest of pillars. We have optimized the micropillar forest design and identified robust measurement conditions that yield a measure of strength that is independent of behavior and gait. Validation studies using a muscle contracting agent and mutants confirm that NemaFlex can reliably score muscular strength in C. elegans. Additionally, we report a scaling factor to account for animal size that is consistent with a biomechanics model and enables comparative strength studies of mutants. Taken together, our findings anchor NemaFlex for applications in genetic and drug screens, for defining molecular and cellular circuits of neuromuscular function, and for dissection of degenerative processes in disuse, aging, and disease.

  4. Strength Measurements of Archive K Basin Sludge Using a Soil Penetrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Delegard, Calvin H.; Schmidt, Andrew J.; Chenault, Jeffrey W.

    2011-12-06

    Spent fuel radioactive sludge present in the K East and K West spent nuclear fuel storage basins now resides in the KW Basin in six large underwater engineered containers. The sludge will be dispositioned in two phases under the Sludge Treatment Project: (1) hydraulic retrieval into sludge transport and storage containers (STSCs) and transport to interim storage in Central Plateau and (2) retrieval from the STSCs, treatment, and packaging for shipment to the Waste Isolation Pilot Plant. In the years the STSCs are stored, sludge strength is expected to increase through chemical reaction, intergrowth of sludge crystals, and compaction andmore » dewatering by settling. Increased sludge strength can impact the type and operation of the retrieval equipment needed prior to final sludge treatment and packaging. It is important to determine whether water jetting, planned for sludge retrieval from STSCs, will be effective. Shear strength is a property known to correlate with the effectiveness of water jetting. Accordingly, the unconfined compressive strengths (UCS) of archive K Basin sludge samples and sludge blends were measured using a pocket penetrometer modified for hot cell use. Based on known correlations, UCS values can be converted to shear strengths. Twenty-six sludge samples, stored in hot cells for a number of years since last being disturbed, were identified as potential candidates for UCS measurement and valid UCS measurements were made for twelve, each of which was found as moist or water-immersed solids at least 1/2-inch deep. Ten of the twelve samples were relatively weak, having consistencies described as 'very soft' to 'soft'. Two of the twelve samples, KE Pit and KC-4 P250, were strong with 'very stiff' and 'stiff' consistencies described, respectively, as 'can be indented by a thumb nail' or 'can be indented by thumb'. Both of these sludge samples are composites collected from KE Basin floor and Weasel Pit locations. Despite both strong sludges having

  5. Strength measurement of optical fibers by bending

    NASA Astrophysics Data System (ADS)

    Srubshchik, Leonid S.

    1999-01-01

    A two-point bending technique has been used not only to measure the breaking stress of optical fiber but also to predict its static and dynamic fatigue. The present theory of this test is based on elastica theory of rod. However, within the limits of elastica theory the tensile and shear stresses cannot be determined. In this paper we study dynamic and static problems for optical fiber in the two- point bending test on the base of geometrically exact theory in which rod can suffer flexure, extension, and shear. We obtain the governing partial differential equations taking into account the fact that the lateral motion of the fiber is restrained by the presence of flat parallel plates. We develop the computational methods for solving the initial and equilibrium free-boundary nonlinear planar problems. We derive the formulas for predicting of the tensile strength from strength in the bending and calculate one example.

  6. Spall Strength Measurements in Transparent Epoxy Polymers

    NASA Astrophysics Data System (ADS)

    Pepper, Jonathan; Rahmat, Meysam; Petel, Oren

    2017-06-01

    Polymer nanocomposites are seeing more frequent use in transparent armour applications. The role of the microstructure on the performance of these materials under dynamic tensile loading conditions is of particular interest. In the present study, a series of plate impact experiments was conducted in order to evaluate the dynamic response of an epoxy (EPON 828) cured with two differed hardeners. The purpose was to compare the role of these hardeners on the dynamic performance of the resulting transparent epoxy. The material response was resolved with a multi-channel photonic Doppler velocimeter. This system was used to determine the shock Hugoniot and dynamic tensile (spall) strength of the materials. The experimental results are presented in reference to spall theory and are evaluated against results predicted by an analytical model of the impacts. While varying the hardener did not change the shock Hugoniot of the epoxy, it did have an effect on the measured spall strengths.

  7. Alternative Penetrometers to Measure the Near Surface Strength of Soft Seafloor Soils

    DTIC Science & Technology

    2010-01-01

    data. The three probe types were a cone penetrometer (CPT), ball penetrometer (BPT), and a shear vane ( VST ). The CPT and BPT measure electronically a...continuous profile of tip and sleeve resistance as well as the porewater pressure during advancement. The VST records the undrained shear strength...results and are compared with the VST shear strengths as shown on Figure 5 (Specimen 1) and Figure 6 (Specimen 2). The VST strengths compare

  8. The Impact of Hand Grip Strength Exercises on the Target Shooting Accuracy Score for Archers

    ERIC Educational Resources Information Center

    Sezer, Süreyya Yonca

    2017-01-01

    The purpose of this research is to investigate the impact of hand grip strength exercises on the target shooting accuracy score for male archers. Thirty male archers (n1 = 15, 19.85 ± 1.35, n2 = 15 19.71 ± 1.31) ranging 18-20 years old were included in our study from the archery team of the city of Elazig, department of youth sports. The…

  9. The Influence of Oropalatal Dimensions on the Measurement of Tongue Strength.

    PubMed

    Pitts, Laura L; Stierwalt, Julie A G; Hageman, Carlin F; LaPointe, Leonard L

    2017-12-01

    Tongue strength is routinely evaluated in clinical swallowing evaluations since lingual weakness is an established contributor to dysphagia. Tongue strength may be clinically quantified by the maximum isometric tongue pressure (MIP) generated by the tongue against the palate; however, wide ranges in normal performance remain to be fully explained. Although orthodontic theory has long suggested a relation between lingual function and oral cavity dimensions, little attention has been given to the potential influence of oral and palatal structure(s) on healthy variance in MIP generation. Therefore, anterior and posterior tongue strength measures and oropalatal dimensions were obtained across 147 healthy adults (aged 18-88 years). Age was confirmed as a significant, independent predictor explaining approximately 10.2% of the variance in anterior tongue strength, but not a significant predictor of posterior tongue strength. However, oropalatal dimensions predicted anterior tongue strength with over three times the predictive power of age alone (p < .001). Significant models for anterior tongue strength (R 2  = .457) and posterior tongue strength (R 2  = .283) included a combination of demographic predictors (i.e., age and/or gender) and oropalatal dimensions. Palatal width, estimated tongue volume, and gender were significant predictors of posterior tongue strength (p < .001). Therefore, oropalatal dimensions may warrant consideration when accurately differentiating between pathological lingual weakness and healthy individual difference.

  10. Mechanical torque measurement for in vivo quantification of bone strength in the proximal femur.

    PubMed

    Mueller, Marc Andreas; Hengg, Clemens; Hirschmann, Michael; Schmid, Denise; Sprecher, Christoph; Audigé, Laurent; Suhm, Norbert

    2012-10-01

    Bone strength determines fracture risk and fixation strength of osteosynthesis implants. In vivo, bone strength is currently measured indirectly by quantifying bone mineral density (BMD) which is however only one determinant of the bone's biomechanical competence besides the bone's macro- and micro-architecture and tissue related parameters. We have developed a measurement principle (DensiProbe™ Hip) for direct, mechanical quantification of bone strength within the proximal femur upon hip fracture fixation. Previous cadaver tests indicated a close correlation between DensiProbe™ Hip measurements, 3D micro-CT analysis and biomechanical indicators of bone strength. The goal of this study was to correlate DensiProbe™ Hip measurements with areal bone mineral density (BMD). Forty-three hip fracture patients were included in this study. Intraoperatively, DensiProbe™ Hip was inserted to the subsequent hip screw tip position within the femoral head. Peak torque to breakaway of local cancellous bone was registered. Thirty-seven patients underwent areal BMD measurements of the contralateral proximal femur. Failure of fixation was assessed radio graphically 6 and 12 weeks postoperatively. Peak torque and femoral neck BMD showed significant correlations (R=0.60, P=0.0001). In regression analysis, areal BMD explained 46% of femoral neck BMD variance in a quadratic relationship. Throughout the 12-week follow-up period, no failure of fixation was observed. DensiProbe™ Hip may capture variations of bone strength beyond areal BMD which are currently difficult to measure in vivo. A multicenter study will clarify if peak torque predicts fixation failure. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Measured oscillator strengths in singly ionized molybdenum

    NASA Astrophysics Data System (ADS)

    Mayo-García, R.; Aragón, C.; Aguilera, J. A.; Ortiz, M.

    2015-11-01

    In this article, 112 oscillator strengths from Mo II have been measured, 79 of which for the first time. The radiative parameters have been obtained by laser-induced breakdown spectroscopy (LIBS). The plasma is produced from a fused glass sample prepared from molybdenum oxide with a Mo atomic concentration of 0.1%. The plasma evolved in air at atmospheric pressure, and measurements were carried out with the following plasma parameters: an electron density of (2.5+/- 0.1)\\cdot {10}17 cm-3 and an electron temperature of 14,400+/- 200 K. In these conditions, a local thermodynamic equilibrium environment and an optically thin plasma were confirmed for the measurements. The relative intensities were placed on an absolute scale by combining branching fractions with the measured lifetimes and by comparing well-known lines using the plasma temperature. Comparisons were made to previously obtained experimental and theoretical values wherever possible.

  12. Measuring Eccentric Strength of the Shoulder External Rotators Using a Handheld Dynamometer: Reliability and Validity

    PubMed Central

    Johansson, Fredrik R.; Skillgate, Eva; Lapauw, Mattis L.; Clijmans, Dorien; Deneulin, Valentijn P.; Palmans, Tanneke; Engineer, Human Kinetic; Cools, Ann M.

    2015-01-01

    Context Shoulder strength assessment plays an important role in the clinical examination of the shoulder region. Eccentric strength measurements are of special importance in guiding the clinician in injury prevention or return-to-play decisions after injury. Objective To examine the absolute and relative reliability and validity of a standardized eccentric strength-measurement protocol for the glenohumeral external rotators. Design Descriptive laboratory study. Setting Testing environment at the Department of Rehabilitation Sciences and Physiotherapy of Ghent University, Belgium. Patients or Other Participants Twenty-five healthy participants (9 men and 16 women) without any history of shoulder pain were tested by 2 independent assessors using a handheld dynamometer (HHD) and underwent an isokinetic testing procedure. Intervention(s) The clinical protocol used an HHD, a DynaPort accelerometer to measure acceleration and angular velocity of testing 30°/s over 90° of range of motion, and a Biodex dynamometer to measure isokinetic activity. Main Outcome Measure(s) Three eccentric strength measurements: (1) tester 1 with the HHD, (2) tester 2 with the HHD, and (3) Biodex isokinetic strength measurement. Results The intratester reliability was excellent (0.879 and 0.858), whereas the intertester reliability was good, with an intraclass correlation coefficient between testers of 0.714. Pearson product moment correlation coefficients of 0.78 and 0.70 were noted between the HHD and the isokinetic data, showing good validity of this new procedure. Conclusions Standardized eccentric rotator cuff strength can be tested and measured in the clinical setting with good-to-excellent reliability and validity using an HHD. PMID:25974381

  13. Direct measurement of resonance strengths in 34S(α ,γ )38Ar at astrophysically relevant energies using the DRAGON recoil separator

    NASA Astrophysics Data System (ADS)

    Connolly, D.; O'Malley, P. D.; Akers, C.; Chen, A. A.; Christian, G.; Davids, B.; Erikson, L.; Fallis, J.; Fulton, B. R.; Greife, U.; Hager, U.; Hutcheon, D. A.; Ilyushkin, S.; Laird, A. M.; Mahl, A.; Ruiz, C.

    2018-03-01

    Background: Nucleosynthesis of mid-mass elements is thought to occur under hot and explosive astrophysical conditions. Radiative α capture on 34S has been shown to impact nucleosynthesis in several such conditions, including core and shell oxygen burning, explosive oxygen burning, and type Ia supernovae. Purpose: Broad uncertainties exist in the literature for the strengths of three resonances within the astrophysically relevant energy range (ECM=1.94 -3.42 MeV at T =2.2 GK ). Further, there are several states in 38Ar within this energy range which have not been previously measured. This work aimed to remeasure the resonance strengths of states for which broad uncertainty existed as well as to measure the resonance strengths and energies of previously unmeasured states. Methods: Resonance strengths and energies of eight narrow resonances (five of which had not been previously studied) were measured in inverse kinematics with the DRAGON facility at TRIUMF by impinging an isotopically pure beam of 34S ions on a windowless 4He gas target. Prompt γ emissions of de-exciting 38Ar recoils were detected in an array of bismuth germanate scintillators in coincidence with recoil nuclei, which were separated from unreacted beam ions by an electromagnetic mass separator and detected by a time-of-flight system and a multianode ionization chamber. Results: The present measurements agree with previous results. Broad uncertainty in the resonance strength of the ECM=2709 keV resonance persists. Resonance strengths and energies were determined for five low-energy resonances which had not been studied previously, and their strengths were determined to be significantly weaker than those of previously measured resonances. Conclusions: The five previously unmeasured resonances were found not to contribute significantly to the total thermonuclear reaction rate. A median total thermonuclear reaction rate calculated using data from the present work along with existing literature values

  14. Preseason shoulder strength measurements in professional baseball pitchers: identifying players at risk for injury.

    PubMed

    Byram, Ian R; Bushnell, Brandon D; Dugger, Keith; Charron, Kevin; Harrell, Frank E; Noonan, Thomas J

    2010-07-01

    The ability to identify pitchers at risk for injury could be valuable to a professional baseball organization. To our knowledge, there have been no prior studies examining the predictive value of preseason strength measurements. Preseason weakness of shoulder external rotators is associated with increased risk of in-season throwing-related injury in professional baseball pitchers. Cohort study (prognosis); Level of evidence, 2. Preseason shoulder strength was measured for all pitchers in a professional baseball organization over a 5-year period (2001-2005). Prone internal rotation (IR), prone external rotation (PER), seated external rotation (SER), and supraspinatus (SS) strength were tested during spring training before each season. The players were then prospectively followed throughout the season for incidence of throwing-related injury. Injuries were categorized on an ordinal scale, with no injury, injury treated conservatively, and injury resulting in surgery delineated 0, 1, and 2, respectively. Subset analyses of shoulder injuries and of players with prior surgery were also performed. The association between strength measurements and injury was analyzed using Spearman rank correlation. A statistically significant association was observed for PER strength (P = .003), SER strength (P = .048), and SS strength (P = .006) with throwing-related injury requiring surgical intervention. Supraspinatus strength was also significantly associated with incidence of any shoulder injury (P = .031). There was an association between the ratio of PER/IR strength and incidence of shoulder injury (P = .037) and some evidence for an association with overall incidence of throwing-related injury (P = .051). No associations were noted in the subgroup of players with prior surgery. Preseason weakness of external rotation and SS strength is associated with in-season throwing-related injury resulting in surgical intervention in professional baseball pitchers. Thus, preseason strength

  15. Development of a novel nanoscratch technique for quantitative measurement of ice adhesion strength

    NASA Astrophysics Data System (ADS)

    Loho, T.; Dickinson, M.

    2018-04-01

    The mechanism for the way that ice adheres to surfaces is still not well understood. Currently there is no standard method to quantitatively measure how ice adheres to surfaces which makes ice surface studies difficult to compare. A novel quantitative lateral force adhesion measurement at the micro-nano scale for ice was created which shears micro-nano sized ice droplets (less than 3 μm in diameter and 100nm in height) using a nanoindenter. By using small ice droplets, the variables associated with bulk ice measurements were minimised which increased data repeatability compared to bulk testing. The technique provided post- testing surface scans to confirm that the ice had been removed and that measurements were of ice adhesion strength. Results show that the ice adhesion strength of a material is greatly affected by the nano-scale surface roughness of the material with rougher surfaces having higher ice adhesion strength.

  16. The assessment of bond strength between heat damaged concrete and high strength fibre reinforced concrete

    NASA Astrophysics Data System (ADS)

    Zahid, M. Z. A. Mohd; Muhamad, K.

    2017-09-01

    The aim of this study is to assess the bond strength between heat damaged concrete and high strength fibre reinforced concrete (HPFRC). Firstly, this paper presents the various steps taken to prepare the HPFRC with self-compacting property. The minimum targeted slump flow is 600 mm and minimum targeted compressive strength is 80 MPa. The key mix variables considered are such as type of superplasticizer, water cement ratio and silica fume content. Then, the bond strength between the heat damaged concrete with HPFRC was examined. The experimental parameters are heating temperature, surface treatment technique and curing method and the results show that, all experimental parameters are significantly affected the bond strength between heat damaged concrete and HPFRC.

  17. Isometric and isokinetic muscle strength in the upper extremity can be reliably measured in persons with chronic stroke.

    PubMed

    Ekstrand, Elisabeth; Lexell, Jan; Brogårdh, Christina

    2015-09-01

    To evaluate the test-retest reliability of isometric and isokinetic muscle strength measurements in the upper extremity after stroke. A test-retest design. Forty-five persons with mild to moderate paresis in the upper extremity > 6 months post-stroke. Isometric arm strength (shoulder abduction, elbow flexion), isokinetic arm strength (elbow extension/flexion) and isometric grip strength were measured with electronic dynamometers. Reliability was evaluated with intra-class correlation coefficients (ICC), changes in the mean, standard error of measurements (SEM) and smallest real differences (SRD). Reliability was high (ICCs: 0.92-0.97). The absolute and relative (%) SEM ranged from 2.7 Nm (5.6%) to 3.0 Nm (9.4%) for isometric arm strength, 2.6 Nm (7.4%) to 2.9 Nm (12.6%) for isokinetic arm strength, and 22.3 N (7.6%) to 26.4 N (9.2%) for grip strength. The absolute and relative (%) SRD ranged from 7.5 Nm (15.5%) to 8.4 Nm (26.1%) for isometric arm strength, 7.1 Nm (20.6%) to 8.0 Nm (34.8%) for isokinetic arm strength, and 61.8 N (21.0%) to 73.3 N (25.6%) for grip strength. Muscle strength in the upper extremity can be reliably measured in persons with chronic stroke. Isometric measurements yield smaller measurement errors than isokinetic measurements and might be preferred, but the choice depends on the research question.

  18. Dentin-Composite Bond Strength Measurement Using the Brazilian Disk Test

    PubMed Central

    Carrera, Carola A.; Chen, Yung-Chung; Li, Yuping; Rudney, Joel; Aparicio, Conrado; Fok, Alex

    2016-01-01

    Objectives This study presents a variant of the Brazilian disk test (BDT) for assessing the bond strength between composite resins and dentin. Methods Dentin-composite disks (φ 5 mm × 2 mm) were prepared using either Z100 or Z250 (3M ESPE) in combination with one of three adhesives, Adper Easy Bond (EB), Adper Scotchbond Multi-Purpose (MP) and Adper Single Bond (SB), and tested under diametral compression. Acoustic emission (AE) and digital image correlation (DIC) were used to monitor debonding of the composite from the dentin ring. A finite element (FE) model was created to calculate the bond strengths using the failure loads. Fracture modes were examined by scanning electron microscopy (SEM). Results Most specimens fractured along the dentin-resin composite interface. DIC and AE confirmed interfacial debonding immediately before fracture of the dentin ring. Results showed that the mean bond strength with EB (14.9±1.9 MPa) was significantly higher than with MP (13.2±2.4 MPa) or SB (12.9±3.0 MPa) (p<0.05); no significant difference was found between MP and SB (p>0.05). Z100 (14.5±2.3 MPa) showed higher bond strength than Z250 (12.7±2.5 MPa) (p<0.05). Majority of specimens (91.3%) showed an adhesive failure mode. EB failed mostly at the dentin-adhesive interface, whereas MP at the composite-adhesive interface; specimens with SB failed at the composite-adhesive interface and cohesively in the adhesive. Conclusions The BDT variant showed to be a suitable alternative for measuring the bond strength between dentin and composite, with zero premature failure, reduced variability in the measurements, and consistent failure at the dentin-composite interface. PMID:27395367

  19. Astronaut candidate strength measurement using the Cybex 2 and the LIDO Multi-Joint 2 dynamometers

    NASA Technical Reports Server (NTRS)

    Carroll, Amy E.; Wilmington, Robert P.

    1992-01-01

    The Anthropometry and Biomechanics Laboratory in the man-Systems division at NASA's Johnson Space Center has as one of its responsibilities the anthropometry and strength measurement data collection of astronaut candidates. The anthropometry data is used to ensure that the astronaut candidates are within the height restrictions for space vehicle and space suit design requirements, for example. The strength data is used to help detect abnormalities or isolate injuries to muscle groups that could jeopardize the astronauts safety. The Cybex II Dynamometer has been used for strength measurements from 1985 through 1991. The Cybex II was one of the first instruments of its kind to measure strength and similarity of muscle groups by isolating the specific joint of interest. In November 1991, a LIDO Multi-Joint II Dynamometer was purchased to upgrade the strength measurement data collection capability of the Anthropometry and Biomechanics Laboratory. The LIDO Multi-Joint II Dynamometer design offers several advantages over the Cybex II Dynamometer including a more sophisticated method of joint isolation and a more accurate and efficient computer based data collection system.

  20. Beyond a Deficit Model of Strengths Training in Schools: Teaching Targeted Strength Use to Gifted Students

    ERIC Educational Resources Information Center

    Bates-Krakoff, Justine; McGrath, Robert E.; Graves, Karen; Ochs, Lynn

    2017-01-01

    Prior literature on the use of character strengths suggests that both deficiencies and excesses in the use of strengths can be problematic. While most school-based training in character strengths tends to focus on the former issue, an example is provided of a school-based program offered by the Mayerson Academy in partnership with the VIA…

  1. Collisional disruption of porous weak sintered targets at low impact velocity

    NASA Astrophysics Data System (ADS)

    Setoh, M.; Nakamura, A. M.; Hirata, N.; Hiraoka, K.; Arakawa, M.

    Porous structure is common in asteroids and satellites of outer planets In order to study the relation between structure of the small bodies and their thermal and collisional evolution we prepared porous sintered targets measured the compressive strength and determined their impact strength Previous studies showed using sintered glass beads Love et al 1993 the targets with higher compressive strength have higher impact strength and the targets with higher porosity have higher impact strength However in these experiments the porosity of the targets were changed according to the compressive strength Therefore we fixed the porosity while the compressive strength was varied Our experiments were performed with low impact velocity condition because low impact velocities are common among icy bodies far from the Earth We sintered soda lime glass beads of 50 micron diameter and 2 5g cm -3 nominal density at various temperatures and durations to produce targets with similar porosity sim 40 and different compressive strength 0 2 sim 7 8MPa We performed impact disruption experiments using a low velocity light-gas gun at Kobe University sim 100m s We used cylindrical polycarbonate projectiles 1 5 cm in height and 1 0 cm in diameter We determined the specific energy J kg of projectile kinetic energy per kilo gram initial target mass for the condition that the largest fragment mass being the half of the initial target mass is the threshold energy for collisional disruption Q Fujiwara et al 1989 Holsapple et al

  2. 47 CFR 2.1053 - Measurements required: Field strength of spurious radiation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... For equipment operating on frequencies below 890 MHz, an open field test is normally required, with... either impractical or impossible to make open field measurements (e.g. a broadcast transmitter installed... 47 Telecommunication 1 2010-10-01 2010-10-01 false Measurements required: Field strength of...

  3. Reliability of measuring hip abductor strength following total knee arthroplasty using a hand-held dynamometer.

    PubMed

    Schache, Margaret B; McClelland, Jodie A; Webster, Kate E

    2016-01-01

    To investigate the test-retest reliability of measuring hip abductor strength in patients with total knee arthroplasty (TKA) using a hand-held dynamometer (HHD) with two different types of resistance: belt and manual resistance. Test-retest reliability of 30 subjects (17 female, 13 male, 71.9 ± 7.4 years old), 9.2 ± 2.7 days post TKA was measured using belt and therapist resistance. Retest reliability was calculated with intra-class coefficients (ICC3,1) and 95% confidence intervals (CI) for both the group average and the individual scores. A paired t-test assessed whether a difference existed between the belt and therapist methods of resistance. ICCs were 0.82 and 0.80 for the belt and therapist resisted methods, respectively. Hip abductor strength increases of 8 N (14%) for belt resisted and 14 N (17%) for therapist resisted measurements of the group average exceeded the 95% CI and may represent real change. For individuals, hip abductor strength increases of 33 N (72%) (belt resisted) and 57 N (79%) (therapist resisted) could be interpreted as real change. Hip abductor strength can be reliably measured using HHD in the clinical setting with the described protocol. Belt resistance demonstrated slightly higher test-retest reliability. Reliable measurement of hip abductor muscle strength in patients with TKA is important to ensure deficiencies are addressed in rehabilitation programs and function is maximized. Hip abductor strength can be reliably measured with a hand-held dynamometer in the clinical setting using manual or belt resistance.

  4. Attentional adjustment to conflict strength: evidence from the effects of manipulating flanker-target SOA on response times and prestimulus pupil size.

    PubMed

    Wendt, Mike; Kiesel, Andrea; Geringswald, Franziska; Purmann, Sascha; Fischer, Rico

    2014-01-01

    Current models of cognitive control assume gradual adjustment of processing selectivity to the strength of conflict evoked by distractor stimuli. Using a flanker task, we varied conflict strength by manipulating target and distractor onset. Replicating previous findings, flanker interference effects were larger on trials associated with advance presentation of the flankers compared to simultaneous presentation. Controlling for stimulus and response sequence effects by excluding trials with feature repetitions from stimulus administration (Experiment 1) or from the statistical analyses (Experiment 2), we found a reduction of the flanker interference effect after high-conflict predecessor trials (i.e., trials associated with advance presentation of the flankers) but not after low-conflict predecessor trials (i.e., trials associated with simultaneous presentation of target and flankers). This result supports the assumption of conflict-strength-dependent adjustment of visual attention. The selective adaptation effect after high-conflict trials was associated with an increase in prestimulus pupil diameter, possibly reflecting increased cognitive effort of focusing attention.

  5. Eversion Strength and Surface Electromyography Measures With and Without Chronic Ankle Instability Measured in 2 Positions.

    PubMed

    Donnelly, Lindsy; Donovan, Luke; Hart, Joseph M; Hertel, Jay

    2017-07-01

    Individuals with chronic ankle instability (CAI) have demonstrated strength deficits compared to healthy controls; however, the influence of ankle position on force measures and surface electromyography (sEMG) activation of the peroneus longus and brevis has not been investigated. The purpose of this study was to compare sEMG amplitudes of the peroneus longus and brevis and eversion force measures in 2 testing positions, neutral and plantarflexion, in groups with and without CAI. Twenty-eight adults (19 females, 9 males) with CAI and 28 healthy controls (19 females, 9 males) participated. Hand-held dynamometer force measures were assessed during isometric eversion contractions in 2 testing positions (neutral, plantarflexion) while surface sEMG amplitudes of the peroneal muscles were recorded. Force measures were normalized to body mass, and sEMG amplitudes were normalized to a resting period. The group with CAI demonstrated less force when compared to the control group ( P < .001) in both the neutral and plantarflexion positions: neutral position, CAI: 1.64 Nm/kg and control: 2.10 Nm/kg) and plantarflexion position, CAI: 1.40 Nm/kg and control: 1.73 Nm/kg). There were no differences in sEMG amplitudes between the groups or muscles ( P > .05). Force measures correlated with both muscles' sEMG amplitudes in the healthy group (neutral peroneus longus: r = 0.42, P = .03; plantarflexion peroneus longus: r = 0.56, P = .002; neutral peroneus brevis: r = 0.38, P = .05; plantarflexion peroneus longus: r = 0.40, P = .04), but not in the group with CAI ( P > .05). The group with CAI generated less force when compared to the control group during both testing positions. There was no selective activation of the peroneal muscles with testing in both positions, and force output and sEMG activity was only related in the healthy group. Clinicians should assess eversion strength and implement strength training exercises in different sagittal plane positions and evaluate for other

  6. Association with isokinetic ankle strength measurements and normal clinical muscle testing in sciatica patients.

    PubMed

    Ustun, N; Erol, O; Ozcakar, L; Ceceli, E; Ciner, O Akar; Yorgancioglu, Z R

    2013-01-01

    Sensitive muscle strength tests are needed to measure muscle strength in the diagnosis and management of sciatica patients. The aim of this study was to assess the isokinetic muscle strength in sciatica patients' and control subjects' ankles that exhibited normal ankle muscle strength when measured clinically. Forty-six patients with L5 and/or S1 nerve compression, and whose age, sex, weight, and height matched 36 healthy volunteers, were recruited to the study. Heel-walking, toe-walking, and manual muscle testing were used to perform ankle dorsiflexion and plantar flexion strengths in clinical examination. Patients with normal ankle dorsiflexion and plantar flexion strengths assessed by manual muscle testing and heel-and toe-walking tests were included in the study. Bilateral isokinetic (concentric/concentric) ankle plantar-flexion-dorsiflexion measurements of the patients and controls were performed within the protocol of 30°/sec (5 repetitions). Peak torque and peak torque/body weight were obtained for each ankle motion of the involved limb at 30°/s speed. L5 and/or S1 nerve compression was evident in 46 patients (76 injured limbs). Mean disease duration was two years. The plantar flexion muscle strength of the patients was found to be lower than that of the controls (p=0.036). The dorsiflexion muscle strength of the patients was found to be the same as that of the controls (p=0.211). Isokinetic testing is superior to clinical muscle testing when evaluating ankle plantar flexion torque in sciatica patients. Therefore, isokinetic muscle testing may be helpful when deciding whether to place a patient into a focused rehabilitation program.

  7. Intra-rater Reliability of Arm and Hand Muscle Strength Measurements in Persons With Late Effects of Polio.

    PubMed

    Brogårdh, Christina; Flansbjer, Ulla-Britt; Carlsson, Håkan; Lexell, Jan

    2015-10-01

    Muscle weakness in the upper limb is common in persons with late effects of polio. To be able to measure muscle strength and follow changes over time, reliable measurements are needed. To evaluate the intra-rater reliability of isometric and isokinetic arm and hand muscle strength measurements in persons with late effects of polio. A test-retest design. A university hospital outpatient clinic. Twenty-eight persons (mean age 68 years, SD 11 years) with late effects of polio in their upper limbs. Isometric shoulder abduction, isokinetic concentric elbow flexion and extension, isometric elbow flexion, and isometric grip strength were measured twice, 14 days apart. Reliability was evaluated with the intra-class correlation coefficient, the mean difference between the test sessions (d¯), together with the 95% confidence intervals for d¯ , the standard error of measurement (SEM and SEM%), the smallest real difference (SRD and SRD%), and Bland-Altman graphs. A fixed dynamometer (Biodex) was used to measure arm strength and an electronic dynamometer (GRIP-it) was used to measure grip strength. Intra-rater reliability was high, with intra-class correlation coefficients between 0.87 and 0.98. The SEM%, representing the smallest change for a group of persons, ranged from 7%-24% for all strength measurements, and the SRD%, representing the smallest change for an individual person, ranged from 20%-67%. Muscle strength in the upper limbs can be reliably measured in persons with late effects of polio. However, the measurement errors indicate that the method is more suitable to detect changes in muscle strength for a group of persons than for an individual person. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  8. Hayward Fault rocks: porosity, density, and strength measurements

    USGS Publications Warehouse

    Morrow, C.A.; Lockner, D.A.

    2001-01-01

    Porosity, density and strength measurements were conducted on rock samples collected from the Hayward Fault region in Northern California as part of the Hayward Fault Working Group’s efforts to create a working model of the Hayward Fault. The rocks included in this study were both fine and coarse grained gabbros, altered keratophyre, basalt, sandstone, and serpentinite from various rock formations adjacent to the Hayward Fault. Densities ranged from a low of 2.25 gm/cc (altered keratophyre) to 3.05 gm/cc (fine gabbro), with an average of 2.6 gm/cc, typical of many other rocks. Porosities were generally around 1% or less, with the exception of the sandstone (7.6%) and altered keratophyre (13.5%). Failure and frictional sliding tests were conducted on intact rock cylinders at room temperature under effective pressure conditions of up to 192 MPa, simulating depths of burial to 12 km. Axial shortening of the samples progressed at a rate of 0.1 µm/sec (fine samples) or 0.2 µm/sec (porous samples) for 6 mm of displacement. Velocity stepping tests were then conducted for an additional 2 mm of displacement, for a total of 8 mm. Both peak strength (usually failure strength) and frictional strength, determined at 8 mm of displacement, increased systematically with effective pressure. Coefficients of friction, based on the observed fracture angles, ranged from 0.6 to 0.85, consistent with Byerlee’s Law. Possible secondary influences on the strength of the Hayward rock samples may be surface weathering, or a larger number of pre-existing fractures due to the proximity to the Hayward Fault. All samples showed velocity strengthening, so that the average a-b values were all strongly positive. There was no systematic relation between a-b values and effective pressure. Velocity strengthening behavior is associated with stable sliding (creep), as observed in the shallow portions of the Hayward Fault.

  9. Isolation of 163Ho from dysprosium target material by HPLC for neutrino mass measurements

    DOE PAGES

    Mocko, Veronika; Taylor, Wayne  A.; Nortier, Francois M.; ...

    2015-04-29

    The rare earth isotope 163Ho is of interest for neutrino mass measurements. This report describes the isolation of 163Ho from a proton-irradiated dysprosium target and its purification. A Dy metal target was irradiated with 16 MeV protons for 10 h. After target dissolution, 163Ho was separated from the bulk Dy via cation-exchange high performance liquid chromatography using 70 mmol dm –3 α-hydroxyisobutyric acid as the mobile phase. Subsequent purification of the collected Ho fraction was performed to remove the α-hydroxyisobutyrate chelating agent and to concentrate the Ho in a low ionic strength aqueous matrix. The final solution was characterized bymore » MC-ICP-MS to determine the 163Ho/ 165Ho ratio, 163Ho and the residual Dy content. The HPLC purification process resulted in a decontamination factor 1.4E5 for Dy. As a result, the isolated Ho fraction contained 24.8 ±1.3 ng of 163Ho corresponding to holmium recovery of 72 ± 3%.« less

  10. Isolation of 163Ho from dysprosium target material by HPLC for neutrino mass measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mocko, Veronika; Taylor, Wayne  A.; Nortier, Francois M.

    The rare earth isotope 163Ho is of interest for neutrino mass measurements. This report describes the isolation of 163Ho from a proton-irradiated dysprosium target and its purification. A Dy metal target was irradiated with 16 MeV protons for 10 h. After target dissolution, 163Ho was separated from the bulk Dy via cation-exchange high performance liquid chromatography using 70 mmol dm –3 α-hydroxyisobutyric acid as the mobile phase. Subsequent purification of the collected Ho fraction was performed to remove the α-hydroxyisobutyrate chelating agent and to concentrate the Ho in a low ionic strength aqueous matrix. The final solution was characterized bymore » MC-ICP-MS to determine the 163Ho/ 165Ho ratio, 163Ho and the residual Dy content. The HPLC purification process resulted in a decontamination factor 1.4E5 for Dy. As a result, the isolated Ho fraction contained 24.8 ±1.3 ng of 163Ho corresponding to holmium recovery of 72 ± 3%.« less

  11. What is preexisting strength? Predicting free association probabilities, similarity ratings, and cued recall probabilities.

    PubMed

    Nelson, Douglas L; Dyrdal, Gunvor M; Goodmon, Leilani B

    2005-08-01

    Measuring lexical knowledge poses a challenge to the study of the influence of preexisting knowledge on the retrieval of new memories. Many tasks focus on word pairs, but words are embedded in associative networks, so how should preexisting pair strength be measured? It has been measured by free association, similarity ratings, and co-occurrence statistics. Researchers interpret free association response probabilities as unbiased estimates of forward cue-to-target strength. In Study 1, analyses of large free association and extralist cued recall databases indicate that this interpretation is incorrect. Competitor and backward strengths bias free association probabilities, and as with other recall tasks, preexisting strength is described by a ratio rule. In Study 2, associative similarity ratings are predicted by forward and backward, but not by competitor, strength. Preexisting strength is not a unitary construct, because its measurement varies with method. Furthermore, free association probabilities predict extralist cued recall better than do ratings and co-occurrence statistics. The measure that most closely matches the criterion task may provide the best estimate of the identity of preexisting strength.

  12. Oscillator strengths and collision strengths for S v

    NASA Technical Reports Server (NTRS)

    Van Wyngaarden, W. L.; Henry, R. J. W.

    1981-01-01

    Observations of the optical extreme-ultraviolet spectrum of the Jupiter planetary system during the Voyager space mission revealed bright emission lines of some sulfur ions. The spectra of the torus at the orbit of Io are likely to contain S V lines. The described investigation provides oscillator strengths and collision strengths for the first four UV lines. The collision strengths from the ground state to four other excited states are also obtained. Use is made of a two-state calculation which is checked for convergence for some transitions by employing a three-state or a four-state approximation. Target wave functions for S V are calculated so that the oscillator strengths calculated in dipole length and dipole velocity approximations agree within 5%.

  13. Relationship between selected measures of strength and hip and knee excursion during unilateral and bilateral landings in women.

    PubMed

    McCurdy, Kevin; Walker, John; Armstrong, Rusty; Langford, George

    2014-09-01

    The purpose of this study was to compare the relationship between several measures of single-joint, isometric, eccentric, and squat strength and unilateral and bilateral landing mechanics at the hip and knee in women. Twenty six healthy female subjects with previous athletic experience (height, 165.1 ± 7.01 cm; mass, 60.91 ± 7.14 kg; age, 20.9 ± 1.62 years) participated in this study. Hip and knee mechanics were measured using the MotionMonitor capture system (Innovative Sports Training, Inc.) with 3-dimensional electromagnetic sensors during bilateral (60 cm) and unilateral drop jumps (30 cm). On a separate day, isometric hip extension, external rotation, and abduction strength (lbs) were measured using a handheld dynamometer (Hoggan Health Industries, Inc.). Eccentric and isometric knee strength were measured on the Biodex IV Isokinetic Dynamometer (Biodex Medical Systems, Inc.). Free weight was used to measure the bilateral squat and a modified single-leg squat. The strongest correlations were found between squat strength and knee valgus (-0.77 ≤ r ≤ -0.83) and hip adduction (-0.5 ≤ r ≤ -0.65). After controlling for squat strength, hip external rotation strength and unilateral knee valgus (-0.41), hip abduction strength and bilateral knee valgus (-0.43), and knee flexion strength and bilateral hip adduction (-0.57) remained significant. Eccentric knee flexion strength and unilateral knee internal rotation was the only significant correlation for eccentric strength (-0.40). Squat strength seems to be the best predictor of knee valgus and was consistently related to hip adduction. Isometric and eccentric measures demonstrated few significant correlations with hip and knee excursion while demonstrating a low-to-moderate relationship. Hip and knee flexion and rotation do not seem to be related to strength. Squat strength should receive consideration during risk assessment for noncontact knee injury.

  14. Relationship Between Muscle Strength Asymmetry and Body Sway in Older Adults.

    PubMed

    Koda, Hitoshi; Kai, Yoshihiro; Murata, Shin; Osugi, Hironori; Anami, Kunihiko; Fukumoto, Takahiko; Imagita, Hidetaka

    2018-05-31

    The purpose of this study was to investigate the relationship between muscle strength asymmetry and body sway while walking. We studied 63 older adult women. Strong side and weak side of knee extension strength, toe grip strength, hand grip strength, and body sway while walking were measured. The relationship between muscle strength asymmetry for each muscle and body sway while walking was evaluated using Pearson's correlation coefficient. Regarding the muscles recognized to have significant correlation with body sway, the asymmetry cutoff value causing an increased sway was calculated. Toe grip strength asymmetry was significantly correlated with body sway. Toe grip strength asymmetry causing an increased body sway had a cutoff value of 23.5%. Our findings suggest toe grip strength asymmetry may be a target for improving gait stability.

  15. Guess Again (and Again and Again): Measuring Password Strength by Simulating Password-Cracking Algorithms

    DTIC Science & Technology

    2011-08-31

    2011 4 . TITLE AND SUBTITLE Guess Again (and Again and Again): Measuring Password Strength by Simulating Password-Cracking Algorithms 5a. CONTRACT...large numbers of hashed passwords (Booz Allen Hamilton, HBGary, Gawker, Sony Playstation , etc.), coupled with the availability of botnets that offer...when evaluating the strength of different password-composition policies. 4 . We investigate the effectiveness of entropy as a measure of password

  16. Variability of strength measurement in postmenopausal women who are overweight or obese: a Monet study.

    PubMed

    St-Onge, Maxime; Mathieu, Marie-Eve; Tousignant, Benoit; Faraj, May; Lavoie, Jean-Marc

    2009-12-01

    The main objective of this study was to establish whether a stable measurement of strength could be obtained without prior exercise familiarization in postmenopausal women who were overweight or obese. A second objective was to evaluate the influence of physical activity on the variability of strength measurement. Thirty postmenopausal women (age: 57.9 yr; SD: 5 yr; body mass index: 31.0 kg/m2; SD: 4 kg/m2) underwent 3 strength testing sessions (48 hr apart) each including 3 exercises (leg press, chest press, and lat pull down). Energy expenditure was measured before the strength testing week with the doubly labelled water method over a 10-day period. Resting metabolic rate was measured by indirect calorimetry. Physical activity energy expenditure was calculated as follows: total energy expenditure x 0.9, minus the resting metabolic rate. Repeated analysis of variance and paired t-test were used to assess the difference and the reliability of the testing sequence. Results from leg press and chest press exercises indicated no significant difference among the 3 testing sessions. The lat pull down exercise was associated with a significant systematic bias between sessions 1 and 2 (mean difference: 1.4 kg; SD: 3 kg; 95% confidence intervals; 0.2-2.7 kg), but the difference disappeared at the third testing session (mean difference: 0.7 kg; SD: 3 kg; 95% confidence intervals; 0.5-2 kg). Physical activity did not influence the variability of the strength results. Overall, our results showed that a relatively stable strength measurement can be obtained within a maximum of 3 testing sessions without prior familiarization. In addition, physical activity did not influence strength testing in postmenopausal women who were overweight or obese.

  17. Object strength--an accurate measure for small objects that is insensitive to partial volume effects.

    PubMed

    Tofts, P S; Silver, N C; Barker, G J; Gass, A

    2005-07-01

    There are currently four problems in characterising small nonuniform lesions or other objects in Magnetic Resonance images where partial volume effects are significant. Object size is over- or under-estimated; boundaries are often not reproducible; mean object value cannot be measured; and fuzzy borders cannot be accommodated. A new measure, Object Strength, is proposed. This is the sum of all abnormal intensities, above a uniform background value. For a uniform object, this is simply the product of the increase in intensity and the size of the object. Biologically, this could be at least as relevant as existing measures of size or mean intensity. We hypothesise that Object Strength will perform better than traditional area measurements in characterising small objects. In a pilot study, the reproducibility of object strength measurements was investigated using MR images of small multiple sclerosis (MS) lesions. In addition, accuracy was investigated using artificial lesions of known volume (0.3-6.2 ml) and realistic appearance. Reproducibility approached that of area measurements (in 33/90 lesion reports the difference between repeats was less than for area measurements). Total lesion volume was accurate to 0.2%. In conclusion, Object Strength has potential for improved characterisation of small lesions and objects in imaging and possibly spectroscopy.

  18. Information-geometric measures as robust estimators of connection strengths and external inputs.

    PubMed

    Tatsuno, Masami; Fellous, Jean-Marc; Amari, Shun-Ichi

    2009-08-01

    Information geometry has been suggested to provide a powerful tool for analyzing multineuronal spike trains. Among several advantages of this approach, a significant property is the close link between information-geometric measures and neural network architectures. Previous modeling studies established that the first- and second-order information-geometric measures corresponded to the number of external inputs and the connection strengths of the network, respectively. This relationship was, however, limited to a symmetrically connected network, and the number of neurons used in the parameter estimation of the log-linear model needed to be known. Recently, simulation studies of biophysical model neurons have suggested that information geometry can estimate the relative change of connection strengths and external inputs even with asymmetric connections. Inspired by these studies, we analytically investigated the link between the information-geometric measures and the neural network structure with asymmetrically connected networks of N neurons. We focused on the information-geometric measures of orders one and two, which can be derived from the two-neuron log-linear model, because unlike higher-order measures, they can be easily estimated experimentally. Considering the equilibrium state of a network of binary model neurons that obey stochastic dynamics, we analytically showed that the corrected first- and second-order information-geometric measures provided robust and consistent approximation of the external inputs and connection strengths, respectively. These results suggest that information-geometric measures provide useful insights into the neural network architecture and that they will contribute to the study of system-level neuroscience.

  19. Bonding measurement -Strength and fracture mechanics approaches.

    PubMed

    Anunmana, Chuchai; Wansom, Wiroj

    2017-07-26

    This study investigated the effect of cross-sectional areas on interfacial fracture toughness and bond strength of bilayered dental ceramics. Zirconia core ceramics were veneered and cut to produce specimens with three different cross-sectional areas. Additionally, monolithic specimens of glass veneer were also prepared. The specimens were tested in tension until fracture at the interface and reported as bond strength. Fracture surfaces were observed, and the apparent interfacial toughness was determined from critical crack size and failure stress. The results showed that cross-sectional area had no effect on the interfacial toughness whereas such factor had a significant effect on interfacial bond strength. The study revealed that cross-sectional area had no effect on the interfacial toughness, but had a significant effect on interfacial bond strength. The interfacial toughness may be a more reliable indicator for interfacial bond quality than interfacial bond strength.

  20. Behavioral patterns and in-situ target strength of the hairtail ( Trichiurus lepturus) via coupling of scientific echosounder and acoustic camera data

    NASA Astrophysics Data System (ADS)

    Hwang, Kangseok; Yoon, Eun-A.; Kang, Sukyung; Cha, Hyungkee; Lee, Kyounghoon

    2017-12-01

    The present study focuses on the influence of target strength (TS) changes in the swimming angle of the hairtail ( Trichiurus lepturus). We measured in-situ TS at 38 and 120 kHz with luring lamps at a fishing ground for jigging boats near the coastal waters of Jeju-do in Korea. Swimming angle and size of hairtails were measured using an acoustic camera. Results showed that mean preanal length was estimated to be 13.5 cm (SD = 2.7 cm) and mean swimming tilt angle was estimated to be 43.9° (SD = 17.6°). The mean TS values were -35.7 and -41.2 dB at 38 and 120 kHz, respectively. The results will assist in understanding the influence of swimming angle on the TS of hairtails and, thus, improve the accuracy of biomass estimates.

  1. Validity of maximal isometric knee extension strength measurements obtained via belt-stabilized hand-held dynamometry in healthy adults.

    PubMed

    Ushiyama, Naoko; Kurobe, Yasushi; Momose, Kimito

    2017-11-01

    [Purpose] To determine the validity of knee extension muscle strength measurements using belt-stabilized hand-held dynamometry with and without body stabilization compared with the gold standard isokinetic dynamometry in healthy adults. [Subjects and Methods] Twenty-nine healthy adults (mean age, 21.3 years) were included. Study parameters involved right side measurements of maximal isometric knee extension strength obtained using belt-stabilized hand-held dynamometry with and without body stabilization and the gold standard. Measurements were performed in all subjects. [Results] A moderate correlation and fixed bias were found between measurements obtained using belt-stabilized hand-held dynamometry with body stabilization and the gold standard. No significant correlation and proportional bias were found between measurements obtained using belt-stabilized hand-held dynamometry without body stabilization and the gold standard. The strength identified using belt-stabilized hand-held dynamometry with body stabilization may not be commensurate with the maximum strength individuals can generate; however, it reflects such strength. In contrast, the strength identified using belt-stabilized hand-held dynamometry without body stabilization does not reflect the maximum strength. Therefore, a chair should be used to stabilize the body when performing measurements of maximal isometric knee extension strength using belt-stabilized hand-held dynamometry in healthy adults. [Conclusion] Belt-stabilized hand-held dynamometry with body stabilization is more convenient than the gold standard in clinical settings.

  2. Test-retest reliability of a handheld dynamometer for measurement of isometric cervical muscle strength.

    PubMed

    Vannebo, Katrine Tranaas; Iversen, Vegard Moe; Fimland, Marius Steiro; Mork, Paul Jarle

    2018-03-02

    There is a lack of test-retest reliability studies of measurements of cervical muscle strength, taking into account gender and possible learning effects. To investigate test-retest reliability of measurement of maximal isometric cervical muscle strength by handheld dynamometry. Thirty women (age 20-58 years) and 28 men (age 20-60 years) participated in the study. Maximal isometric strength (neck flexion, neck extension, and right/left lateral flexion) was measured on three separate days at least five days apart by one evaluator. Intra-rater consistency tended to improve from day 1-2 measurements to day 2-3 measurements in both women and men. In women, the intra-class correlation coefficients (ICC) for day 2 to day 3 measurements were 0.91 (95% confidence interval [CI], 0.82-0.95) for neck flexion, 0.88 (95% CI, 0.76-0.94) for neck extension, 0.84 (95% CI, 0.68-0.92) for right lateral flexion, and 0.89 (95% CI, 0.78-0.95) for left lateral flexion. The corresponding ICCs among men were 0.86 (95% CI, 0.72-0.93) for neck flexion, 0.93 (95% CI, 0.85-0.97) for neck extension, 0.82 (95% CI, 0.65-0.91) for right lateral flexion and 0.73 (95% CI, 0.50-0.87) for left lateral flexion. This study describes a reliable and easy-to-administer test for assessing maximal isometric cervical muscle strength.

  3. Dynamic Tensile Strength of Low Temperature Ice and Kuiper Belt Size Distributions

    NASA Astrophysics Data System (ADS)

    Ahrens, Thomas J.; Fat'yanov, O. V.; Engelhardt, H.; Fraser, W. C.

    2009-09-01

    We model mutual gravitationally driven impact interactions in a nearly gas-free environment of the Kuiper belt (KB) and use low-temperature (< 100 K) ice dynamic strength dependent collisional out-come (accretion vs. erosion and fragmentation) models. These lead to theoretically predictable distributions of object number density, vs. mass distributions. These derived mass distributions are comparable to the now rapidly growing KB survey data. Tensional failure of single and polycrystalline ice in the temperature range from 263 to 128 K was measured for high strain rate, c.a. 104 s-1, dynamic loading conditions. Experiments, similar to Lange and Ahrens(1991)(LA), were conducted using a gas gun launched Lexan projectile. The liquid nitrogen cooled ice target approaching KB-like temperatures was partially confined, rather than using the LA confined geometry. Another set of experiments used a drop tube projectile launcher within the 263 K Caltech Ice Laboratory and at 163 K in a liquid nitrogen cooled chamber. New experiments give tensile strengths of 7.6±1.5 MPa at 263 K and 9.1±1.5 MPa at 163 K for unconfined, free of visual initial defects and measurable imperfections ice samples. The new strengths are lower than the earlier LA data ( 17 MPa). The major differences arise from ice target assembly. LA used polycrystalline ice samples confined in annular stainless steel target rings. New measurements were partially confined, in not initially contacting concentric target rings. Later shots used unconfined configurations with ice pellets affixed to aluminum foil. Circumferential confinement is known to increase the material damage threshold upon both compression and tensile loading. Previous confinement in LA is the main cause of the above discrepancy. Present tensile strengths are only a few times higher than 0.7 - 3.0 MPa summarized in Petrovic (2003) for quasistatic tension at 10-7 to 10-3 s-1 strain rate.

  4. Alternative Penetrometers to Measure the Near Surface Strength of Soft Seafloor Soils

    DTIC Science & Technology

    2011-01-01

    recorded data. The three probe types were a cone penetrometer (CPT), ball penetrometer (BPT), and a shear vane ( VST ). The CPT and BPT measure...electronically a continuous profile of tip and sleeve resistance as well as the porewater pressure during advancement. The VST records the undrained shear...test results and are compared with the VST shear strengths as shown on Figure 5 (Specimen 1) and Figure 6 (Specimen 2). The VST strengths compare

  5. Repeatability and Reproducibility of Compression Strength Measurements Conducted According to ASTM E9

    NASA Technical Reports Server (NTRS)

    Luecke, William E.; Ma, Li; Graham, Stephen M.; Adler, Matthew A.

    2010-01-01

    Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.

  6. Assessment of Behavioral and Emotional Strengths in Black Children: Development of the Behavioral Assessment for Children of African Heritage

    ERIC Educational Resources Information Center

    Lambert, Michael Canute; Rowan, George T.; Kim, Soyoun; Rowan, Scott A.; An Shin, Jeong; Kirsch, Elizabeth A.; Williams, Olivia

    2005-01-01

    Absence of culturally relevant measures of Black children's strengths inhibits psychometrically sound strength-based assessment, research, and appropriate use of strengths as scaffolds or targets for clinical intervention. Moreover, the sparse research literature on Black children is primarily deficit focused. Beginning to address these problems,…

  7. Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength.

    PubMed

    Douma, K W; Regterschot, G R H; Krijnen, W P; Slager, G E C; van der Schans, C P; Zijlstra, W

    2016-01-01

    The ability to generate muscle strength is a pre-requisite for all human movement. Decreased quadriceps muscle strength is frequently observed in older adults and is associated with a decreased performance and activity limitations. To quantify the quadriceps muscle strength and to monitor changes over time, instruments and procedures with a sufficient reliability are needed. The Q Force is an innovative mobile muscle strength measurement instrument suitable to measure in various degrees of extension. Measurements between 110 and 130° extension present the highest values and the most significant increase after training. The objective of this study is to determine the test-retest reliability of muscle strength measurements by the Q Force in older adults in 110° extension. Forty-one healthy older adults, 13 males and 28 females were included in the study. Mean (SD) age was 81.9 (4.89) years. Isometric muscle strength of the Quadriceps muscle was assessed with the Q Force at 110° of knee extension. Participants were measured at two sessions with a three to eight day interval between sessions. To determine relative reliability, the intraclass correlation coefficient (ICC) was calculated. To determine absolute reliability, Bland and Altman Limits of Agreement (LOA) were calculated and t-tests were performed. Relative reliability of the Q Force is good to excellent as all ICC coefficients are higher than 0.75. Generally a large 95 % LOA, reflecting only moderate absolute reliability, is found as exemplified for the peak torque left leg of -18.6 N to 33.8 N and the right leg of -9.2 N to 26.4 N was between 15.7 and 23.6 Newton representing 25.2 % to 39.9 % of the size of the mean. Small systematic differences in mean were found between measurement session 1 and 2. The present study shows that the Q Force has excellent relative test-retest reliability, but limited absolute test-retest reliability. Since the Q Force is relatively cheap and mobile it is suitable for

  8. Measures of Functional Performance and Their Association With Hip and Thigh Strength

    PubMed Central

    Kollock, Roger; Van Lunen, Bonnie L.; Ringleb, Stacie I.; Oñate, James A.

    2015-01-01

    Context: Insufficient hip and thigh strength may increase an athlete's susceptibility to injury. However, screening for strength deficits using isometric and isokinetic instrumentation may not be practical in all clinical scenarios. Objective: To determine if functional performance tests are valid indicators of hip and thigh strength. Design: Descriptive laboratory study. Setting: Research laboratory. Patients or Other Participants: Sixty-two recreationally athletic men (n = 30, age = 21.07 years, height = 173.84 cm, mass = 81.47 kg) and women (n = 32, age = 21.03 years, height = 168.77 cm, mass = 68.22 kg) participants were recruited. Intervention(s): During session 1, we measured isometric peak force and rate of force development for 8 lower extremity muscle groups, followed by an isometric endurance test. During session 2, participants performed functional performance tests. Main Outcome Measure(s): Peak force, rate of force development, fatigue index, hop distance (or height), work (joules), and number of hops performed during the 30-second lateral-hop test were assessed. The r values were squared to calculate r 2. We used Pearson correlations to evaluate the associations between functional performance and strength. Results: In men, the strongest relationship was observed between triple-hop work and hip-adductor peak force (r2 = 50, P ≤ .001). Triple-hop work also was related to hip-adductor (r2 = 38, P ≤ .01) and hip-flexor (r2 = 37, P ≤ .01) rate of force development. For women, the strongest relationships were between single-legged vertical-jump work and knee-flexor peak force (r2 = 0.44, P ≤ .01) and single-legged vertical-jump height and knee-flexor peak force (r2 = 0.42, P ≤ .01). Single-legged vertical-jump height also was related to knee-flexor rate of force development (r2 = 0.49, P ≤ .001). The 30-second lateral-hop test did not account for a significant portion of the variance in strength endurance. Conclusions: Hop tests alone did not

  9. The role of strength defects in shaping impact crater planforms

    NASA Astrophysics Data System (ADS)

    Watters, W. A.; Geiger, L. M.; Fendrock, M.; Gibson, R.; Hundal, C. B.

    2017-04-01

    High-resolution imagery and digital elevation models (DEMs) were used to measure the planimetric shapes of well-preserved impact craters. These measurements were used to characterize the size-dependent scaling of the departure from circular symmetry, which provides useful insights into the processes of crater growth and modification. For example, we characterized the dependence of the standard deviation of radius (σR) on crater diameter (D) as σR ∼ Dm. For complex craters on the Moon and Mars, m ranges from 0.9 to 1.2 among strong and weak target materials. For the martian simple craters in our data set, m varies from 0.5 to 0.8. The value of m tends toward larger values in weak materials and modified craters, and toward smaller values in relatively unmodified craters as well as craters in high-strength targets, such as young lava plains. We hypothesize that m ≈ 1 for planforms shaped by modification processes (slumping and collapse), whereas m tends toward ∼ 1/2 for planforms shaped by an excavation flow that was influenced by strength anisotropies. Additional morphometric parameters were computed to characterize the following planform properties: the planform aspect ratio or ellipticity, the deviation from a fitted ellipse, and the deviation from a convex shape. We also measured the distribution of crater shapes using Fourier decomposition of the planform, finding a similar distribution for simple and complex craters. By comparing the strength of small and large circular harmonics, we confirmed that lunar and martian complex craters are more polygonal at small sizes. Finally, we have used physical and geometrical principles to motivate scaling arguments and simple Monte Carlo models for generating synthetic planforms, which depend on a characteristic length scale of target strength defects. One of these models can be used to generate populations of synthetic planforms which are very similar to the measured population of well-preserved simple craters on

  10. Towards traceability in CO2 line strength measurements by TDLAS at 2.7 µm

    NASA Astrophysics Data System (ADS)

    Pogány, Andrea; Ott, Oliver; Werhahn, Olav; Ebert, Volker

    2013-11-01

    Direct tunable diode laser absorption spectroscopy (TDLAS) was combined in this study with metrological principles on the determination of uncertainties to measure the line strengths of the P36e and P34e line of 12C16O2 in the ν1+ν3 band at 2.7 μm. Special emphasis was put on traceability and a concise, well-documented uncertainty assessment. We have quantitatively analyzed the uncertainty contributions of different experimental parameters to the uncertainty of the line strength. Establishment of the wavenumber axis and the gas handling procedure proved to be the two major contributors to the final uncertainty. The obtained line strengths at 296 K are 1.593×10-20 cm/molecule for the P36e and 1.981×10-20 cm/molecule for the P34e line, with relative expanded uncertainties of 1.1% and 1.3%, respectively (k=2, corresponding to a 95% confidence level). The measured line strength values are in agreement with literature data (line strengths listed in the HITRAN and GEISA databases), but show an uncertainty, which is at least a factor of 2 lower.

  11. Comparison of Extravehicular Mobility Unit (EMU) suited and unsuited isolated joint strength measurements

    NASA Technical Reports Server (NTRS)

    Maida, James C.; Demel, Kenneth J.; Morgan, David A.; Wilmington, Robert P.; Pandya, Abhilash K.

    1996-01-01

    In this study the strength of subjects suited in extravehicular mobility units (EMU's) - or Space Shuttle suits - was compared to the strength of unsuited subjects. The authors devised a systematic and complete data set that characterizes isolated joint torques for all major joints of EMU-suited subjects. Six joint motions were included in the data set. The joint conditions of six subjects were compared to increase our understanding of the strength capabilities of suited subjects. Data were gathered on suited and unsuited subjects. Suited subjects wore Class 3 or Class 1 suits, with and without thermal micrometeoroid garments (TMG's). Suited and unsuited conditions for each joint motion were compared. From this the authors found, for example, that shoulder abduction suited conditions differ from each other and from the unsuited condition. A second-order polynomial regression model was also provided. This model, which allows the prediction of suited strength when given unsuited strength information, relates the torques of unsuited conditions to the torques of all suited conditions. Data obtained will enable computer modeling of EMU strength, conversion from unsuited to suited data, and isolated joint strength comparisons between suited and unsuited conditions at any measured angle. From these data mission planners and human factors engineers may gain a better understanding of crew posture, and mobility and strength capabilities. This study also may help suit designers optimize suit strength, and provide a foundation for EMU strength modeling systems.

  12. Automatic measurement of target crossing speed

    NASA Astrophysics Data System (ADS)

    Wardell, Mark; Lougheed, James H.

    1992-11-01

    The motion of ground vehicle targets after a ballistic round is launched can be a major source of inaccuracy for small (handheld) anti-armour weapon systems. A method of automatically measuring the crossing component to compensate the fire control solution has been devised and tested against various targets in a range of environments. A photodetector array aligned with the sight's horizontal reticle obtains scene features, which are digitized and processed to separate target from sight motion. Relative motion of the target against the background is briefly monitored to deduce angular crossing rate and a compensating lead angle is introduced into the aim point. Research to gather quantitative data and optimize algorithm performance is described, and some results from field testing are presented.

  13. Hugoniot-measurements of room- and high-temperature metals for study of EOS and strength

    NASA Astrophysics Data System (ADS)

    Mashimo, Tsutomu; Gomoto, Yuya; Takashima, Hideyuki; Murai, Mitsuru; Yoshiasa, Akira

    2011-06-01

    Pressure calibration in static high-pressure experiments has been undertaken on the basis of the EOS derived from the Hugoniot compression curves of metals (Au, Pt, Cu, W, etc.), MgO, etc. To obtain the strict EOS at room- and high-temperatures, we need to precisely measure the Hugoniot data, and access the strength and Grüneisen parameter under shock compression. If the Hugoniot data of elevated temperature samples are measured, the high-temperature EOS can be accurately derived, and the Grüneisen parameter can be directly discussed. The strength might decrease at high temperature. The Hugoniot-measurement experiments have been performed on single crystal Au, oxygen-free Cu, forged Ta and W by a streak photographic system equipped with a powder gun and two-stage light gas gun in the pressure range up to >200 GPa. In addition, the Hugoniot-measurement experiment of the elevated temperature samples was started using high-frequency heating on W, Au, etc. Some of the results will be presented, and the EOS and strength are discussed.

  14. Reference Values of Grip Strength, Prevalence of Low Grip Strength, and Factors Affecting Grip Strength Values in Chinese Adults.

    PubMed

    Yu, Ruby; Ong, Sherlin; Cheung, Osbert; Leung, Jason; Woo, Jean

    2017-06-01

    The objectives of this study were to update the reference values of grip strength, to estimate the prevalence of low grip strength, and to examine the impact of different aspects of measurement protocol on grip strength values in Chinese adults. A cross-sectional survey of Chinese men (n = 714) and women (n = 4014) aged 18-102 years was undertaken in different community settings in Hong Kong. Grip strength was measured with a digital dynamometer (TKK 5401 Grip-D; Takei, Niigata, Japan). Low grip strength was defined as grip strength 2 standard deviations or more below the mean for young adults. The effects of measurement protocol on grip strength values were examined in a subsample of 45 men and women with repeated measures of grip strength taken with a hydraulic dynamometer (Baseline; Fabrication Enterprises Inc, Irvington, NY), using pair t-tests, intraclass correlation coefficient, and Bland and Altman plots. Grip strength was greater among men than among women (P < .001) and the rate of decline differed between sexes (P < .001). The prevalence of low grip strength also increased with age, reaching a rate of 16.5% in men and 20.6% in women aged 65+. Although the TKK digital dynamometer gave higher grip strength values than the Baseline hydraulic dynamometer (P < .001), the degree of agreement between the 2 dynamometers was satisfactory. Higher grip strength values were also observed when the measurement was performed with the elbow extended in a standing position, compared with that with the elbow flexed at 90° in a sitting position, using the same dynamometer (P < .05). This study updated the reference values of grip strength and estimated the prevalence of low grip strength among Chinese adults spanning a wide age range. These findings might be useful for risk estimation and evaluation of interventions. However, grip strength measurements should be interpreted with caution, as grip strength values can be affected by type of dynamometer used

  15. The effect of depth on the target strength of a humpback whale (Megaptera novaeangliae).

    PubMed

    Bernasconi, M; Patel, R; Nøttestad, L; Pedersen, G; Brierley, A S

    2013-12-01

    Marine mammals are very seldom detected and tracked acoustically at different depths. The air contained in body cavities, such as lungs or swimbladders, has a significant effect on the acoustic energy backscattered from whale and fish species. Target strength data were obtained while a humpback whale (Megaptera novaeangliae) swam at the surface and dove underneath a research vessel, providing valuable multi-frequency echosounder recordings of its scattering characteristics from near surface to a depth of about 240 m. Increasing depth dramatically influenced the backscattered energy coming from the large cetacean. This study is tightly linked to the ultimate goal of developing an automated whale detection system for mitigation purposes.

  16. Relative strengths of the calf muscles based on MRI volume measurements.

    PubMed

    Jeng, Clifford L; Thawait, Gaurav K; Kwon, John Y; Machado, Antonio; Boyle, James W; Campbell, John; Carrino, John A

    2012-05-01

    In 1985, Silver et al. published a cadaver study which determined the relative order of strength of the muscles in the calf. Muscle strength, which is proportional to volume, was obtained by dissecting out the individual muscles, weighing them, and then multiplying by the specific gravity. No similar studies have been performed using {\\it in vivo} measurements of muscle volume. Ten normal subjects underwent 3-Tesla MRI's of both lower extremities using non-fat-saturated T2 SPACE sequences. The volume for each muscle was determined by tracing the muscle contour on sequential axial images and then interpolating the volume using imaging software. The results from this study differ from Silver's original article. The lateral head of the gastrocnemius was found to be stronger than the tibialis anterior muscle. The FHL and EDL muscles were both stronger than the peroneus longus. There was no significant difference in strength between the peroneus longus and brevis muscles. This revised order of muscle strengths in the calf based on in vivo MRI findings may assist surgeons in determining the optimal tendons to transfer in order to address muscle weakness and deformity.

  17. Targeting DMPK with Antisense Oligonucleotide Improves Muscle Strength in Myotonic Dystrophy Type 1 Mice.

    PubMed

    Jauvin, Dominic; Chrétien, Jessina; Pandey, Sanjay K; Martineau, Laurie; Revillod, Lucille; Bassez, Guillaume; Lachon, Aline; MacLeod, A Robert; Gourdon, Geneviève; Wheeler, Thurman M; Thornton, Charles A; Bennett, C Frank; Puymirat, Jack

    2017-06-16

    Myotonic dystrophy type 1 (DM1), a dominant hereditary muscular dystrophy, is caused by an abnormal expansion of a (CTG) n trinucleotide repeat in the 3' UTR of the human dystrophia myotonica protein kinase (DMPK) gene. As a consequence, mutant transcripts containing expanded CUG repeats are retained in nuclear foci and alter the function of splicing regulatory factors members of the MBNL and CELF families, resulting in alternative splicing misregulation of specific transcripts in affected DM1 tissues. In the present study, we treated DMSXL mice systemically with a 2'-4'-constrained, ethyl-modified (ISIS 486178) antisense oligonucleotide (ASO) targeted to the 3' UTR of the DMPK gene, which led to a 70% reduction in CUG exp RNA abundance and foci in different skeletal muscles and a 30% reduction in the heart. Furthermore, treatment with ISIS 486178 ASO improved body weight, muscle strength, and muscle histology, whereas no overt toxicity was detected. This is evidence that the reduction of CUG exp RNA improves muscle strength in DM1, suggesting that muscle weakness in DM1 patients may be improved following elimination of toxic RNAs. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  18. Oxygenator Safety Evaluation: A Focus on Connection Grip Strength and Arterial Temperature Measurement Accuracy

    PubMed Central

    Newland, Richard F.; Baker, Robert A.; Sanderson, Andrew J.; Tuble, Sigrid C.; Tully, Phil J.

    2012-01-01

    Abstract: This report describes the assessment of three specific safety-related specifications in the consideration of an alternate oxygenator; first the grip strength relationship between various oxygenator connectors and SMARxT® tubing, second, the grip strength of various biopassive tubings and an isolated SMARxT® connector, and finally, the accuracy of the arterial outlet temperature measurement. Grip strength experiments for the connections between the SMARxT® tubing and the venous reservoir outlet and the oxygenator venous inlet and oxygenator arterial outlet of the Medtronic Affinity®, Sorin Synthesis®, Sorin Primox®, and Terumo Capiox® RX25 oxygenators were performed. In addition we compared the grip strength of polyvinyl chloride, Physio®, Trillium®, Carmeda®, X-Coating®, and SMARxT® tubing. The accuracy of the integrated arterial outlet temperature probes was determined by comparing the temperatures measured by the integrated probe with a precision reference thermometer. Connector grip strength comparisons for the evaluation oxygenators with SMARxT® tubing showed significant variation between oxygenators and connections (p = .02). Evaluation of the arterial outlet showed significant variation between evaluation oxygenators, while at the venous reservoir outlet and oxygenator inlet, there were no significant differences. Grip strength comparison data for the various tubing types demonstrated a main effect for tubing type F(5, 18) = 8.01, p = .002, ηp2 = .77. Temperature accuracy measurements demonstrated that all oxygenators overread the arterial outlet temperature at 15°C, whilst at temperatures ≥25°C, all oxygenators underread the arterial outlet temperature. The integrity of SMARxT® tubing connection is influenced by the connector type, and may decline over time, highlighting the importance to not consider interchanging components of the bypass circuit as inconsequential. PMID:22893983

  19. Measures of Strength and Fitness for Older Populations.

    ERIC Educational Resources Information Center

    Osness, Wayne H.; Hiebert, Lujean M.

    The overall strength of the musculature does not require testing of large numbers of muscle groups and can be accomplished from three or four tests. Small batteries of strength tests have been devised to predict total strength. The best combination of tests for males are thigh flexors, leg extensors, arm flexors, and pectoralis major. The battery…

  20. Quadriceps Strength in Patients With Isolated Cartilage Defects of the Knee: Results of Isokinetic Strength Measurements and Their Correlation With Clinical and Functional Results

    PubMed Central

    Hirschmüller, Anja; Andres, Tasja; Schoch, Wolfgang; Baur, Heiner; Konstantinidis, Lukas; Südkamp, Norbert P.; Niemeyer, Philipp

    2017-01-01

    Background: Recent studies have found a significant deficit of maximum quadriceps strength after autologous chondrocyte implantation (ACI) of the knee. However, it is unclear whether muscular strength deficits in patients with cartilage damage exist prior to operative treatment. Purpose: To isokinetically test maximum quadriceps muscle strength and quantify the impact of possible strength deficits on functional and clinical test results. Study Design: Cross-sectional study; Level of evidence, 3. Methods: To identify clinically relevant muscular strength deficits, 24 patients (5 females, 19 males; mean age, 34.5 years; body mass index, 25.9 kg/m2) with isolated cartilage defects (mean onset, 5.05 years; SD, 7.8 years) in the knee joint underwent isokinetic strength measurements. Maximal quadriceps strength was recorded in 3 different testing modes: pure concentric contraction (flexors and extensors alternating work; con1), concentric-eccentric (only the extensors work concentrically and eccentrically; con2), and eccentric contraction in the alternating mode (ecc). Results were compared for functional performance (single-leg hop test), pain scales (visual analog scale [VAS], numeric rating scale [NRS]), self-reported questionnaires (International Knee Documentation Committee [IKDC], Knee Injury and Osteoarthritis Outcome Scale [KOOS]), and defect size (cm2). Results: Compared with the uninjured leg, significantly lower quadriceps strength was detected in the injured leg in all isokinetic working modes (con1 difference, 27.76 N·m [SD 17.47; P = .003]; con2 difference, 21.45 N·m [SD, 18.45; P =.025]; ecc difference, 29.48 N·m [SD, 21.51; P = .001]), with the largest deficits found for eccentric muscle performance. Moderate negative correlations were observed for the subjective pain scales NRS and VAS. The results of the IKDC and KOOS questionnaires showed low, nonsignificant correlations with findings in the isokinetic measurement. Moreover, defect sizes (mean, 3

  1. Reliability and validity of the Performance Recorder 1 for measuring isometric knee flexor and extensor strength.

    PubMed

    Neil, Sarah E; Myring, Alec; Peeters, Mon Jef; Pirie, Ian; Jacobs, Rachel; Hunt, Michael A; Garland, S Jayne; Campbell, Kristin L

    2013-11-01

    Muscular strength is a key parameter of rehabilitation programs and a strong predictor of functional capacity. Traditional methods to measure strength, such as manual muscle testing (MMT) and hand-held dynamometry (HHD), are limited by the strength and experience of the tester. The Performance Recorder 1 (PR1) is a strength assessment tool attached to resistance training equipment and may be a time- and cost-effective tool to measure strength in clinical practice that overcomes some limitations of MMT and HHD. However, reliability and validity of the PR1 have not been reported. Test-retest and inter-rater reliability was assessed using the PR1 in healthy adults (n  =  15) during isometric knee flexion and extension. Criterion-related validity was assessed through comparison of values obtained from the PR1 and Biodex® isokinetic dynamometer. Test-retest reliability was excellent for peak knee flexion (intra-class correlation coefficient [ICC] of 0.96, 95% CI: 0.85, 0.99) and knee extension (ICC  =  0.96, 95% CI: 0.87, 0.99). Inter-rater reliability was also excellent for peak knee flexion (ICC  =  0.95, 95% CI: 0.85, 0.99) and peak knee extension (ICC  =  0.97, 95% CI: 0.91, 0.99). Validity was moderate for peak knee flexion (ICC  =  0.75, 95% CI: 0.38, 0.92) but poor for peak knee extension (ICC  =  0.37, 95% CI: 0, 0.73). The PR1 provides a reliable measure of isometric knee flexor and extensor strength in healthy adults that could be used in the clinical setting, but absolute values may not be comparable to strength assessment by gold-standard measures.

  2. Camouflage target detection via hyperspectral imaging plus information divergence measurement

    NASA Astrophysics Data System (ADS)

    Chen, Yuheng; Chen, Xinhua; Zhou, Jiankang; Ji, Yiqun; Shen, Weimin

    2016-01-01

    Target detection is one of most important applications in remote sensing. Nowadays accurate camouflage target distinction is often resorted to spectral imaging technique due to its high-resolution spectral/spatial information acquisition ability as well as plenty of data processing methods. In this paper, hyper-spectral imaging technique together with spectral information divergence measure method is used to solve camouflage target detection problem. A self-developed visual-band hyper-spectral imaging device is adopted to collect data cubes of certain experimental scene before spectral information divergences are worked out so as to discriminate target camouflage and anomaly. Full-band information divergences are measured to evaluate target detection effect visually and quantitatively. Information divergence measurement is proved to be a low-cost and effective tool for target detection task and can be further developed to other target detection applications beyond spectral imaging technique.

  3. Interfacial Shear Strength of Multilayer Graphene Oxide Films.

    PubMed

    Daly, Matthew; Cao, Changhong; Sun, Hao; Sun, Yu; Filleter, Tobin; Singh, Chandra Veer

    2016-02-23

    Graphene oxide (GO) is considered as one of the most promising layered materials with tunable physical properties and applicability in many important engineering applications. In this work, the interfacial behavior of multilayer GO films was directly investigated via GO-to-GO friction force microscopy, and the interfacial shear strength (ISS) was measured to be 5.3 ± 3.2 MPa. Based on high resolution atomic force microscopy images and the available chemical data, targeted molecular dynamics simulations were performed to evaluate the influence of functional structure, topological defects, and interlayer registry on the shear response of the GO films. Theoretical values for shear strength ranging from 17 to 132 MPa were predicted for the different structures studied, providing upper bounds for the ISS. Computational results also revealed the atomic origins of the stochastic nature of friction measurements. Specifically, the wide scatter in experimental measurements was attributed to variations in functional structure and topological defects within the sliding volume. The findings of this study provide important insight for understanding the significant differences in strength between monolayer and bulk graphene oxide materials and can be useful for engineering topological structures with tunable mechanical properties.

  4. Intrarater reliability of the Humac NORM isokinetic dynamometer for strength measurements of the knee and shoulder muscles.

    PubMed

    Habets, Bas; Staal, J Bart; Tijssen, Marsha; van Cingel, Robert

    2018-01-10

    To determine the intrarater reliability of the Humac NORM isokinetic dynamometer for concentric and eccentric strength tests of knee and shoulder muscles. 54 participants (50% female, average age 20.9 ± 3.1 years) performed concentric and eccentric strength measures of the knee extensors and flexors, and the shoulder internal and external rotators on two different Humac NORM isokinetic dynamometers, which were situated at two different centers. The knee extensors and flexors were tested concentrically at 60° and 180°/s, and eccentrically at 60° s. Concentric strength of the shoulder internal and external rotators, and eccentric strength of the external rotators were measured at 60° and 120°/s. We calculated intraclass correlation coefficients (ICCs), standard error of measurement, standard error of measurement expressed as a %, and the smallest detectable change to determine reliability and measurement error. ICCs for the knee tests ranged from 0.74 to 0.89, whereas ICC values for the shoulder tests ranged from 0.72 to 0.94. Measurement error was highest for the concentric test of the knee extensors and lowest for the concentric test of shoulder external rotators.

  5. Is a sphygmomanometer a valid and reliable tool to measure the isometric strength of hip muscles? A systematic review.

    PubMed

    Toohey, Liam Anthony; De Noronha, Marcos; Taylor, Carolyn; Thomas, James

    2015-02-01

    Muscle strength measurement is a key component of physiotherapists' assessment and is frequently used as an outcome measure. A sphygmomanometer is an instrument commonly used to measure blood pressure that can be potentially used as a tool to assess isometric muscle strength. To systematically review the evidence on the reliability and validity of a sphygmomanometer for measuring isometric strength of hip muscles. A literature search was conducted across four databases. Studies were eligible if they presented data on reliability and/or validity, used a sphygmomanometer to measure isometric muscle strength of the hip region, and were peer reviewed. The individual studies were evaluated for quality using a standardized critical appraisal tool. A total of 644 articles were screened for eligibility, with five articles chosen for inclusion. The use of a sphygmomanometer to objectively assess isometric muscle strength of the hip muscles appears to be reliable with intraclass correlation coefficient values ranging from 0.66 to 0.94 in elderly and young populations. No studies were identified that have assessed the validity of a sphygmomanometer. The sphygmomanometer appears to be reliable for assessment of isometric muscle strength around the hip joint, but further research is warranted to establish its validity.

  6. Predicting drug-target interaction for new drugs using enhanced similarity measures and super-target clustering.

    PubMed

    Shi, Jian-Yu; Yiu, Siu-Ming; Li, Yiming; Leung, Henry C M; Chin, Francis Y L

    2015-07-15

    Predicting drug-target interaction using computational approaches is an important step in drug discovery and repositioning. To predict whether there will be an interaction between a drug and a target, most existing methods identify similar drugs and targets in the database. The prediction is then made based on the known interactions of these drugs and targets. This idea is promising. However, there are two shortcomings that have not yet been addressed appropriately. Firstly, most of the methods only use 2D chemical structures and protein sequences to measure the similarity of drugs and targets respectively. However, this information may not fully capture the characteristics determining whether a drug will interact with a target. Secondly, there are very few known interactions, i.e. many interactions are "missing" in the database. Existing approaches are biased towards known interactions and have no good solutions to handle possibly missing interactions which affect the accuracy of the prediction. In this paper, we enhance the similarity measures to include non-structural (and non-sequence-based) information and introduce the concept of a "super-target" to handle the problem of possibly missing interactions. Based on evaluations on real data, we show that our similarity measure is better than the existing measures and our approach is able to achieve higher accuracy than the two best existing algorithms, WNN-GIP and KBMF2K. Our approach is available at http://web.hku.hk/∼liym1018/projects/drug/drug.html or http://www.bmlnwpu.org/us/tools/PredictingDTI_S2/METHODS.html. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. A novel dentin bond strength measurement technique using a composite disk in diametral compression.

    PubMed

    Huang, Shih-Hao; Lin, Lian-Shan; Rudney, Joel; Jones, Rob; Aparicio, Conrado; Lin, Chun-Pin; Fok, Alex

    2012-04-01

    New methods are needed that can predict the clinical failure of dental restorations that primarily rely on dentin bonding. Existing methods have shortcomings, e.g. severe deviation in the actual stress distribution from theory and a large standard deviation in the measured bond strength. We introduce here a novel test specimen by examining an endodontic model for dentin bonding. Specifically, we evaluated the feasibility of using the modified Brazilian disk test to measure the post-dentin interfacial bond strength. Four groups of resin composite disks which contained a slice of dentin with or without an intracanal post in the center were tested under diametral compression until fracture. Advanced nondestructive examination and imaging techniques in the form of acoustic emission (AE) and digital image correlation (DIC) were used innovatively to capture the fracture process in real time. DIC showed strain concentration first appearing at one of the lateral sides of the post-dentin interface. The appearance of the interfacial strain concentration also coincided with the first AE signal detected. Utilizing both the experimental data and finite-element analysis, the bond/tensile strengths were calculated to be: 11.2 MPa (fiber posts), 12.9 MPa (metal posts), 8.9 MPa (direct resin fillings) and 82.6 MPa for dentin. We have thus established the feasibility of using the composite disk in diametral compression to measure the bond strength between intracanal posts and dentin. The new method has the advantages of simpler specimen preparation, no premature failure, more consistent failure mode and smaller variations in the calculated bond strength. Copyright © 2012 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  8. Target Recognition Using Neural Networks for Model Deformation Measurements

    NASA Technical Reports Server (NTRS)

    Ross, Richard W.; Hibler, David L.

    1999-01-01

    Optical measurements provide a non-invasive method for measuring deformation of wind tunnel models. Model deformation systems use targets mounted or painted on the surface of the model to identify known positions, and photogrammetric methods are used to calculate 3-D positions of the targets on the model from digital 2-D images. Under ideal conditions, the reflective targets are placed against a dark background and provide high-contrast images, aiding in target recognition. However, glints of light reflecting from the model surface, or reduced contrast caused by light source or model smoothness constraints, can compromise accurate target determination using current algorithmic methods. This paper describes a technique using a neural network and image processing technologies which increases the reliability of target recognition systems. Unlike algorithmic methods, the neural network can be trained to identify the characteristic patterns that distinguish targets from other objects of similar size and appearance and can adapt to changes in lighting and environmental conditions.

  9. Intra-rater reliability of hallux flexor strength measures using the Nintendo Wii Balance Board.

    PubMed

    Quek, June; Treleaven, Julia; Brauer, Sandra G; O'Leary, Shaun; Clark, Ross A

    2015-01-01

    The purpose of this study was to investigate the intra-rater reliability of a new method in combination with the Nintendo Wii Balance Board (NWBB) to measure the strength of hallux flexor muscle. Thirty healthy individuals (age: 34.9 ± 12.9 years, height: 170.4 ± 10.5 cm, weight: 69.3 ± 15.3 kg, female = 15) participated. Repeated testing was completed within 7 days. Participants performed strength testing in sitting using a wooden platform in combination with the NWBB. This new method was set up to selectively recruit an intrinsic muscle of the foot, specifically the flexor hallucis brevis muscle. Statistical analysis was performed using intra-class coefficients and ordinary least product analysis. To estimate measurement error, standard error of measurement (SEM), minimal detectable change (MDC) and percentage error were calculated. Results indicate excellent intra-rater reliability (ICC = 0.982, CI = 0.96-0.99) with an absence of systematic bias. SEM, MDC and percentage error value were 0.5, 1.4 and 12 % respectively. This study demonstrates that a new method in combination with the NWBB application is reliable to measure hallux flexor strength and has potential to be used for future research and clinical application.

  10. Measuring Radiofrequency and Microwave Radiation from Varying Signal Strengths

    NASA Technical Reports Server (NTRS)

    Davis, Bette; Gaul, W. C.

    2007-01-01

    This viewgraph presentation discusses the process of measuring radiofrequency and microwave radiation from various signal strengths. The topics include: 1) Limits and Guidelines; 2) Typical Variable Standard (IEEE) Frequency Dependent; 3) FCC Standard 47 CFR 1.1310; 4) Compliance Follows Unity Rule; 5) Multiple Sources Contribute; 6) Types of RF Signals; 7) Interfering Radiations; 8) Different Frequencies Different Powers; 9) Power Summing - Peak Power; 10) Contribution from Various Single Sources; 11) Total Power from Multiple Sources; 12) Are You Out of Compliance?; and 13) In Compliance.

  11. Research on measurement of aviation magneto ignition strength and balance

    NASA Astrophysics Data System (ADS)

    Gao, Feng; He, Zhixiang; Zhang, Dingpeng

    2017-12-01

    Aviation magneto ignition system failure accounted for two-thirds of the total fault aviation piston engine and above. At present the method used for this failure diagnosis is often depended on the visual inspections in the civil aviation maintenance field. Due to human factors, the visual inspections cannot provide ignition intensity value and ignition equilibrium deviation value among the different spark plugs in the different cylinder of aviation piston engine. So air magneto ignition strength and balance testing has become an aviation piston engine maintenance technical problem needed to resolve. In this paper, the ultraviolet sensor with detection wavelength of 185~260nm and driving voltage of 320V DC is used as the core of ultraviolet detection to detect the ignition intensity of Aviation magneto ignition system and the balance deviation of the ignition intensity of each cylinder. The experimental results show that the rotational speed within the range 0 to 3500 RPM test error less than 0.34%, ignition strength analysis and calculation error is less than 0.13%, and measured the visual inspection is hard to distinguish between high voltage wire leakage failure of deviation value of 200 pulse ignition strength balance/Sec. The method to detect aviation piston engine maintenance of magneto ignition system fault has a certain reference value.

  12. Strength Determinants of Jump Height in the Jump Throw Movement in Women Handball Players.

    PubMed

    McGhie, David; Østerås, Sindre; Ettema, Gertjan; Paulsen, Gøran; Sandbakk, Øyvind

    2018-06-08

    McGhie, D, Østerås, S, Ettema, G, Paulsen, G, and Sandbakk, Ø. Strength determinants of jump height in the jump throw movement in women handball players. J Strength Cond Res XX(X): 000-000, 2018-The purpose of the study was to improve the understanding of the strength demands of a handball-specific jump through examining the associations between jump height in a jump throw jump (JTJ) and measures of lower-body maximum strength and impulse in handball players. For comparison, whether the associations between jump height and strength differed between the JTJ and the customarily used countermovement jump (CMJ) was also examined. Twenty women handball players from a Norwegian top division club participated in the study. Jump height was measured in the JTJ and in unilateral and bilateral CMJ. Lower-body strength (maximum isometric force, one-repetition maximum [1RM], impulse at ∼60% and ∼35% 1RM) was measured in seated leg press. The associations between jump height and strength were assessed with correlation analyses and t-tests of dependent r's were performed to determine if correlations differed between jump tests. Only impulse at ∼35% 1RM correlated significantly with JTJ height (p < 0.05), whereas all strength measures correlated significantly with CMJ heights (p < 0.001). The associations between jump height and strength were significantly weaker in the JTJ than in both CMJ tests for all strength measures (p = 0.001-0.044) except one. Maximum strength and impulse at ∼60% 1RM did not seem to sufficiently capture the capabilities associated with JTJ height, highlighting the importance of employing tests targeting performance-relevant neuromuscular characteristics when assessing jump-related strength in handball players. Further, CMJ height seemed to represent a wider range of strength capabilities and care should be taken when using it as a proxy for handball-specific movements.

  13. Measuring Quadriceps strength in adults with severe or moderate intellectual and visual disabilities: Feasibility and reliability.

    PubMed

    Dijkhuizen, Annemarie; Douma, Rob K; Krijnen, Wim P; van der Schans, Cees P; Waninge, Aly

    2018-05-30

    A feasible and reliable instrument to measure strength in persons with severe intellectual and visual disabilities (SIVD) is lacking. The aim of our study was to determine feasibility, learning period and reliability of three strength tests. Twenty-nine participants with SIVD performed the Minimum Sit-to-Stand Height test (MSST), the Leg Extension test (LE) and the 30 seconds Chair-Stand test (30sCS), once per week for 5 weeks. Feasibility was determined by the percentage of successful measurements; learning effect by using paired t test between two consecutive measurements; test-retest reliability by intraclass correlation coefficient and Limits of Agreement and, correlations by Pearson correlations. A sufficient feasibility and learning period of the tests was shown. The methods had sufficient test-retest reliability and moderate-to-sufficient correlations. The MSST, the LE, and the 30sCS are feasible tests for measuring muscle strength in persons with SIVD, having sufficient test re-test reliability. © 2018 John Wiley & Sons Ltd.

  14. Spatial electron density and electric field strength measurements in microwave cavity experiments

    NASA Technical Reports Server (NTRS)

    Peters, M.; Rogers, J.; Whitehair, S.; Asmussen, J.; Kerber, R.

    1984-01-01

    Measurements of electron density and electric field strength have been made in an argon plasma contained in a resonant microwave cavity at 2.45 GHz. Spatial measurements of electron density, n sub e, are correlated with fluorescence observations of the discharge. Measurements of n sub e were made with Stark broadening and compared with n sub 3 calculated from measured plasma conductivity. Additional measurements of n sub 3 as a function of pressure and in mixtures of argon and oxygen are presented for pressures from 10 Torr to 1 atm. Measurements in flowing gases and in static systems are presented. In addition, limitations of these measurements are identified.

  15. Measurement of the photoneutron flux density distribution from cylindrical targets

    NASA Astrophysics Data System (ADS)

    Golovkov, V. M.; Basina, T. N.; Yakovlev, M. R.

    1989-09-01

    Measurements are performed of the density of photoneutron fluxes from cylindrical targets of2H2O (diameter 64 and height 86 mm), Be (outer diameter 70, inner diameter 40, height 100mm), and238U (diameter 44.5 mm, height 50 mm) under the action of braking radiation from electrons with energies of 4 to 8 MeV in order to determine the effect of target form and orientation relative to the detector upon the recorded photoneutron level. The fluxes were measured by an “all-wave” neutron detector based on an SNM-11 counter in a paraffin retarder at an angle of 90‡ to the axis of the braking radiation beam for various target orientations relative to the detector. Measurement results are compared to calculations. Photoneutron fluxes from heavy water and beryllium targets of the indicated dimensions were also measured for angles of 90, 135, and 167‡. An isotropic nature was noted in the photoneutron fluxes from both targets.

  16. Quantification of hand function by power grip and pinch strength force measurements in ulnar nerve lesion simulated by ulnar nerve block.

    PubMed

    Wachter, Nikolaus Johannes; Mentzel, Martin; Krischak, Gert D; Gülke, Joachim

    2017-06-24

    In the assessment of hand and upper limb function, grip strength is of the major importance. The measurement by dynamometers has been established. In this study, the effect of a simulated ulnar nerve lesion on different grip force measurements was evaluated. In 25 healthy volunteers, grip force measurement was done by the JAMAR dynamometer (Fabrication Enterprises Inc, Irvington, NY) for power grip and by a pinch strength dynamometer for tip pinch strength, tripod grip, and key pinch strength. A within-subject research design was used in this prospective study. Each subject served as the control by preinjection measurements of grip and pinch strength. Subsequent measurements after ulnar nerve block were used to examine within-subject change. In power grip, there was a significant reduction of maximum grip force of 26.9% with ulnar nerve block compared with grip force without block (P < .0001). Larger reductions in pinch strength were observed with block: 57.5% in tip pinch strength (P < .0001), 61.0% in tripod grip (P < .0001), and 58.3% in key pinch strength (P < .0001). The effect of the distal ulnar nerve block on grip and pinch force could be confirmed. However, the assessment of other dimensions of hand strength as tip pinch, tripod pinch and key pinch had more relevance in demonstrating hand strength changes resulting from an distal ulnar nerve lesion. The measurement of tip pinch, tripod grip and key pinch can improve the follow-up in hand rehabilitation. II. Copyright © 2017 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  17. 47 CFR 1.544 - Application for broadcast station to conduct field strength measurements and for experimental...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Application for broadcast station to conduct field strength measurements and for experimental operation. 1.544 Section 1.544 Telecommunication... General Filing Requirements § 1.544 Application for broadcast station to conduct field strength...

  18. Comments on extracting the resonance strength parameter from yield data

    DOE PAGES

    Croft, Stephen; Favalli, Andrea

    2015-06-23

    The F(α,n) reaction is the focus of on-going research in part because it is an important source of neutrons in the nuclear fuel cycle which can be exploited to assay nuclear materials, especially uranium in the form of UF 6. At the present time there remains some considerable uncertainty (of the order of ± 20%) in the thick target integrated over angle (α,n) yield from 19F (100% natural abundance) and its compounds as discussed. An important thin target cross-section measurement is that of Wrean and Kavanagh who explore the region from below threshold (2.36 MeV) to approximately 3.1 MeV withmore » fine energy resolution. Integration of their cross-section data over the slowing down history of a stopping α-particle allows the thick target yield to be calculated for incident energies up to 3.1 MeV. This trend can then be combined with data from other sources to obtain a thick target yield curve over the wider range of interest to the fuel cycle (roughly threshold to 10 MeV to include all relevant α-emitters). To estimate the thickness of the CaF 2 target they used, Wrean and Kavanagh separately measured the integrated yield of the 6.129 MeV γ-rays from the resonance at 340.5 keV (laboratory α-particle kinetic energy) in the 19F(p,αγ) reaction. To interpret the data they adopted a resonance strength parameter of (22.3 ± 0.8) eV based on a determination by Becker et al. The value and its uncertainty directly affects the thickness estimate and the extracted (α,n) cross-section values. In their citation to Becker et al's work, Wrean and Kavanagh comment that they did not make use of an alternative value of (23.7±1.0) eV reported by Croft because they were unable to reproduce the value from the data given in that paper. The value they calculated for the resonance strength from the thick target yield given by Croft was 21.4 eV. The purpose of this communication is to revisit the paper by Croft published in this journal and specifically to explain the origin

  19. The fracture strength and frictional strength of Weber Sandstone

    USGS Publications Warehouse

    Byerlee, J.D.

    1975-01-01

    The fracture strength and frictional strength of Weber Sandstone have been measured as a function of confining pressure and pore pressure. Both the fracture strength and the frictional strength obey the law of effective stress, that is, the strength is determined not by the confining pressure alone but by the difference between the confining pressure and the pore pressure. The fracture strength of the rock varies by as much as 20 per cent depending on the cement between the grains, but the frictional strength is independent of lithology. Over the range 0 2 kb, ??=0??5 + 0??6??n. This relationship also holds for other rocks such as gabbro, dunite, serpentinite, granite and limestone. ?? 1975.

  20. Generation and associative encoding in young and old adults: the effect of the strength of association between cues and targets on a cued recall task.

    PubMed

    Taconnat, Laurence; Froger, Charlotte; Sacher, Mathilde; Isingrini, Michel

    2008-01-01

    The generation effect (i.e., better recall of the generated items than the read items) was investigated with a between-list design in young and elderly participants. The generation task difficulty was manipulated by varying the strength of association between cues and targets. Overall, strong associates were better recalled than weak associates. However, the results showed different generation effect patterns according to strength of association and age, with a greater generation effect for weak associates in younger adults only. These findings suggest that generating weak associates leads to more elaborated encoding, but that elderly adults cannot use this elaborated encoding as well as younger adults to recall the target words at test.

  1. Low-Budget Instrumentation of a Conventional Leg Press to Measure Reliable Isometric-Strength Capacity.

    PubMed

    Baur, Heiner; Groppa, Alessia Severina; Limacher, Regula; Radlinger, Lorenz

    2016-02-02

    Maximum strength and rate of force development (RFD) are 2 important strength characteristics for everyday tasks and athletic performance. Measurements of both parameters must be reliable. Expensive isokinetic devices with isometric modes are often used. The possibility of cost-effective measurements in a practical setting would facilitate quality control. The purpose of this study was to assess the reliability of measurements of maximum isometric strength (Fmax) and RFD on a conventional leg press. Sixteen subjects (23 ± 2 y, 1.68 ± 0.05 m, 59 ± 5 kg) were tested twice within 1 session. After warm-up, subjects performed 2 times 5 trials eliciting maximum voluntary isometric contractions on an instrumented leg press (1- and 2-legged randomized). Fmax (N) and RFD (N/s) were extracted from force-time curves. Reliability was determined for Fmax and RFD by calculating the intraclass correlation coefficient (ICC), the test-retest variability (TRV), and the bias and limits of agreement. Reliability measures revealed good to excellent ICCs of .80-.93. TRV showed mean differences between measurement sessions of 0.4-6.9%. The systematic error was low compared with the absolute mean values (Fmax 5-6%, RFD 1-4%). The implementation of a force transducer into a conventional leg press provides a viable procedure to assess Fmax and RFD. Both performance parameters can be assessed with good to excellent reliability allowing quality control of interventions.

  2. A process-oriented measure of habit strength for moderate-to-vigorous physical activity

    PubMed Central

    Grove, J. Robert; Zillich, Irja; Medic, Nikola

    2014-01-01

    Purpose: Habitual action is an important aspect of health behaviour, but the relevance of various habit strength indicators continues to be debated. This study focused specifically on moderate-to-vigorous physical activity (MVPA) and evaluated the construct validity of a framework emphasizing patterned action, stimulus-response bonding, automaticity, and negative consequences for nonperformance as indicators of habit strength for this form of exercise. Methods: Upper-level undergraduates (N = 124) provided demographic information and responded to questionnaire items assessing historical MVPA involvement, current MVPA involvement, and the four proposed habit strength dimensions. Factor analyses were used to examine the latent structure of the habit strength indicators, and the model's construct validity was evaluated via an examination of relationships with repetition history and current behaviour. Results: At a measurement level, findings indicated that the proposed four-component model possessed psychometric integrity as a coherent set of factors. Criterion-related validity was also demonstrated via significant changes in three of the four factors as a function of past involvement in MVPA and significant correlations with the frequency, duration, and intensity of current MVPA. Conclusions: These findings support the construct validity of this exercise habit strength model and suggest that it could provide a template for future research on how MVPA habits are developed and maintained. PMID:25750789

  3. A process-oriented measure of habit strength for moderate-to-vigorous physical activity.

    PubMed

    Grove, J Robert; Zillich, Irja; Medic, Nikola

    2014-01-01

    Purpose : Habitual action is an important aspect of health behaviour, but the relevance of various habit strength indicators continues to be debated. This study focused specifically on moderate-to-vigorous physical activity (MVPA) and evaluated the construct validity of a framework emphasizing patterned action, stimulus-response bonding, automaticity, and negative consequences for nonperformance as indicators of habit strength for this form of exercise. Methods : Upper-level undergraduates ( N  = 124) provided demographic information and responded to questionnaire items assessing historical MVPA involvement, current MVPA involvement, and the four proposed habit strength dimensions. Factor analyses were used to examine the latent structure of the habit strength indicators, and the model's construct validity was evaluated via an examination of relationships with repetition history and current behaviour. Results : At a measurement level, findings indicated that the proposed four-component model possessed psychometric integrity as a coherent set of factors. Criterion-related validity was also demonstrated via significant changes in three of the four factors as a function of past involvement in MVPA and significant correlations with the frequency, duration, and intensity of current MVPA. Conclusions : These findings support the construct validity of this exercise habit strength model and suggest that it could provide a template for future research on how MVPA habits are developed and maintained.

  4. Performance Measurement and Target-Setting in California's Safety Net Health Systems.

    PubMed

    Hemmat, Shirin; Schillinger, Dean; Lyles, Courtney; Ackerman, Sara; Gourley, Gato; Vittinghoff, Eric; Handley, Margaret; Sarkar, Urmimala

    Health policies encourage implementing quality measurement with performance targets. The 2010-2015 California Medicaid waiver mandated quality measurement and reporting. In 2013, California safety net hospitals participating in the waiver set a voluntary performance target (the 90th percentile for Medicare preferred provider organization plans) for mammography screening and cholesterol control in diabetes. They did not reach the target, and the difference-in-differences analysis suggested that there was no difference for mammography ( P = .39) and low-density lipoprotein control ( P = .11) performance compared to measures for which no statewide quality improvement initiative existed. California's Medicaid waiver was associated with improved performance on a number of metrics, but this performance was not attributable to target setting on specific health conditions. Performance may have improved because of secular trends or systems improvements related to waiver funding. Relying on condition-specific targets to measure performance may underestimate improvements and disadvantage certain health systems. Achieving ambitious targets likely requires sustained fiscal, management, and workforce investments.

  5. Technique for measurement of energy loss of proton in target medium

    NASA Astrophysics Data System (ADS)

    Khadke, U. V.

    2018-05-01

    Energy loss (EL) of charged particles in target medium needs special attention, when measurements are required to be done repeatedly over periods of couple of days. It is imperative to ensure that the measurements are not affected by the long term drifts of the accelerator beam energy and the associated electronic modules. For one such situation in measurement of EL of proton beam in thick target, we optimised and standardized the technique of measuring most probable energy loss of 24.774 MeV proton in aluminium target of thickness 330 mg/cm2. The paper described the method that we developed to ensure that our EL measurements were free from effects of drifts due to any associated electronic modules. The details of the energy spectrometer, basic principle and technique for energy loss measurements in target medium are described in this paper.

  6. The Association between Maximal Bench Press Strength and Isometric Handgrip Strength among Breast Cancer Survivors

    PubMed Central

    Rogers, Benjamin H.; Brown, Justin C.; Gater, David R.; Schmitz, Kathryn H.

    2016-01-01

    Objective One-repetition maximum (1-RM) bench press strength is considered the gold standard to quantify upper-body muscular strength. Isometric handgrip strength is frequently used as a surrogate for 1-RM bench press strength among breast cancer (BrCa) survivors. The relationship between 1-RM bench press strength and isometric handgrip strength, however, has not been characterized among BrCa survivors. Design Cross-sectional study. Setting Laboratory. Participants Community-dwelling BrCa survivors. Interventions Not applicable. Main Outcome Measure 1-RM bench press strength was measured with a barbell and exercise bench. Isometric handgrip strength was measured using an isometric dynamometer with three maximal contractions of left and right hands. All measures were conducted by staff with training in clinical exercise testing. Results Among 295 BrCa survivors, 1-RM bench press strength was 18.2±6.1 kg (range: 2.2-43.0) and isometric handgrip strength was 23.5±5.8 kg (range: 9.0-43.0). The strongest correlate of 1-RM bench press strength was the average isometric handgrip strength of both hands (r=0.399; P<0.0001). Mean-difference analysis suggested that the average isometric handgrip strength of both hands overestimated 1-RM bench press strength by 4.7 kg (95% limits of agreement: −8.2 to 17.6). In a multivariable linear regression model, the average isometric handgrip strength of both hands (β=0.31; P<0.0001) and age (β=−0.20; P<0.0001) were positively correlated with 1-RM bench press strength (R2=0.23). Conclusions Isometric handgrip strength is a poor surrogate for 1-RM bench press strength among BrCa survivors. 1-RM bench press and isometric handgrip strength quantify distinct components of muscular strength. PMID:27543047

  7. Responsiveness of performance-based outcome measures for mobility, balance, muscle strength and manual dexterity in adults with myotonic dystrophy type 1.

    PubMed

    Kierkegaard, Marie; Petitclerc, Émilie; Hébert, Luc J; Mathieu, Jean; Gagnon, Cynthia

    2018-02-28

    To assess changes and responsiveness in outcome measures of mobility, balance, muscle strength and manual dexterity in adults with myotonic dystrophy type 1. A 9-year longitudinal study conducted with 113 patients. The responsiveness of the Timed Up and Go test, Berg Balance Scale, quantitative muscle testing, grip and pinch-grip strength, and Purdue Pegboard Test was assessed using criterion and construct approaches. Patient-reported perceived changes (worse/stable) in balance, walking, lower-limb weakness, stair-climbing and hand weakness were used as criteria. Predefined hypotheses about expected area under the receiver operating characteristic curves (criterion approach) and correlations between relative changes (construct approach) were explored. The direction and magnitude of median changes in outcome measures corresponded with patient-reported changes. Median changes in the Timed Up and Go test, grip strength, pinch-grip strength and Purdue Pegboard Test did not, in general, exceed known measurement errors. Most criterion (72%) and construct (70%) approach hypotheses were supported. Promising responsiveness was found for outcome measures of mobility, balance and muscle strength. Grip strength and manual dexterity measures showed poorer responsiveness. The performance-based outcome measures captured changes over the 9-year period and responsiveness was promising. Knowledge of measurement errors is needed to interpret the meaning of these longitudinal changes.

  8. Preliminary evaluation of adhesion strength measurement devices for ceramic/titanium matrix composite bonds

    NASA Technical Reports Server (NTRS)

    Pohlchuck, Bobby; Zeller, Mary V.

    1992-01-01

    The adhesive bond between ceramic cement and a titanium matrix composite substrate to be used in the National Aerospace Plane program is evaluated. Two commercially available adhesion testers, the Sebastian Adherence Tester and the CSEM REVETEST Scratch Tester, are evaluated to determine their suitability for quantitatively measuring adhesion strength. Various thicknesses of cements are applied to several substrates, and bond strengths are determined with both testers. The Sabastian Adherence Tester has provided limited data due to an interference from the sample mounting procedure, and has been shown to be incapable of distinguishing adhesion strength from tensile and shear properties of the cement itself. The data from the scratch tester has been found to be difficult to interpret due to the porosity and hardness of the cement. Recommendations are proposed for a more reliable adhesion test method.

  9. Hand-held dynamometry in patients with haematological malignancies: Measurement error in the clinical assessment of knee extension strength

    PubMed Central

    Knols, Ruud H; Aufdemkampe, Geert; de Bruin, Eling D; Uebelhart, Daniel; Aaronson, Neil K

    2009-01-01

    Background Hand-held dynamometry is a portable and inexpensive method to quantify muscle strength. To determine if muscle strength has changed, an examiner must know what part of the difference between a patient's pre-treatment and post-treatment measurements is attributable to real change, and what part is due to measurement error. This study aimed to determine the relative and absolute reliability of intra and inter-observer strength measurements with a hand-held dynamometer (HHD). Methods Two observers performed maximum voluntary peak torque measurements (MVPT) for isometric knee extension in 24 patients with haematological malignancies. For each patient, the measurements were carried out on the same day. The main outcome measures were the intraclass correlation coefficient (ICC ± 95%CI), the standard error of measurement (SEM), the smallest detectable difference (SDD), the relative values as % of the grand mean of the SEM and SDD, and the limits of agreement for the intra- and inter-observer '3 repetition average' and the 'highest value of 3 MVPT' knee extension strength measures. Results The intra-observer ICCs were 0.94 for the average of 3 MVPT (95%CI: 0.86–0.97) and 0.86 for the highest value of 3 MVPT (95%CI: 0.71–0.94). The ICCs for the inter-observer measurements were 0.89 for the average of 3 MVPT (95%CI: 0.75–0.95) and 0.77 for the highest value of 3 MVPT (95%CI: 0.54–0.90). The SEMs for the intra-observer measurements were 6.22 Nm (3.98% of the grand mean (GM) and 9.83 Nm (5.88% of GM). For the inter-observer measurements, the SEMs were 9.65 Nm (6.65% of GM) and 11.41 Nm (6.73% of GM). The SDDs for the generated parameters varied from 17.23 Nm (11.04% of GM) to 27.26 Nm (17.09% of GM) for intra-observer measurements, and 26.76 Nm (16.77% of GM) to 31.62 Nm (18.66% of GM) for inter-observer measurements, with similar results for the limits of agreement. Conclusion The results indicate that there is acceptable relative reliability for

  10. Measuring the Strength of the Horned Passalus Beetle, Odontotaenius disjunctus: Revisiting an Old Topic with Modern Technology

    PubMed Central

    Davis, Andrew K.; Attarha, Barrett; Piefke, Taylor J.

    2013-01-01

    Over a century ago, a pioneering researcher cleverly devised a means to measure how much weight the horned passalus beetle, Odontotaenius disjunctus (Illiger) (Coleoptera: Passalidae), could pull using a series of springs, pulleys, and careful observation. The technology available in modern times now allows for more rigorous data collection on this topic, which could have a number of uses in scientific investigations. In this study, an apparatus was constructed using a dynamometer and a data logger in an effort to ascertain the pulling strength of this species. By allowing beetles to pull for 10 min, each beetle's mean and maximum pulling force (in Newtons) were obtained for analyses, and whether these measures are related was determined. Then, whether factors such as body length, thorax size, horn size, or gender affect either measure of strength was investigated. Basic body measurements, including horn size, of males versus females were compared. The measurements of 38 beetles (20 females, 18 males) showed there was no difference in overall body length between sexes, but females had greater girth (thorax width) than males, which could translate into larger muscle mass. A total of 21 beetles (10 females, 11 males) were tested for pulling strength. The grand mean pulling force was 0.14 N, and the grand mean maximum was 0.78 N. Despite the fact that beetles tended to pull at 20% of their maximum capacity most of the time, and that maximum force was over 5 times larger than the mean force, the 2 measures were highly correlated, suggesting they may be interchangeable for research purposes. Females had twice the pulling strength (both maximum and mean force) as males in this species overall, but when the larger thorax size of females was considered, the effect of gender was not significant. Beetle length was not a significant predictor of pulling force, but horn size was associated with maximum force. The best predictor of both measures of strength appeared to be

  11. Validity evidence for the measurement of the strength of motivation for medical school.

    PubMed

    Kusurkar, Rashmi; Croiset, Gerda; Kruitwagen, Cas; ten Cate, Olle

    2011-05-01

    The Strength of Motivation for Medical School (SMMS) questionnaire is designed to determine the strength of motivation of students particularly for medical study. This research was performed to establish the validity evidence for measuring strength of motivation for medical school. Internal structure and relations to other variables were used as the sources of validity evidence. The SMMS questionnaire was filled out by 1,494 medical students in different years of medical curriculum. The validity evidence for the internal structure was analyzed by principal components analysis with promax rotation. Validity evidence for relations to other variables was tested by comparing the SMMS scores with scores on the Academic Motivation Scale (AMS) and the exhaustion scale of Maslach Burnout Inventory-Student Survey (MBI-SS) for measuring study stress. Evidence for internal consistency was determined through the Cronbach's alpha for reliability. The analysis showed that the SMMS had a 3-factor structure. The validity in relations to other variables was established as both, the subscales and full scale scores significantly correlated positively with the intrinsic motivation scores and with the more autonomous forms of extrinsic motivation, the correlation decreasing and finally becoming negative towards the extrinsic motivation end of the spectrum. They also had significant negative correlations with amotivation scale of the AMS and exhaustion scale of MBI-SS. The Cronbach's alpha for reliability of the three subscales and full SMMS scores was 0.70, 0.67, 0.55 and 0.79. The strength of motivation for medical school has a three factor structure and acceptable validity evidence was found in our study.

  12. Association Between Maximal Bench Press Strength and Isometric Handgrip Strength Among Breast Cancer Survivors.

    PubMed

    Rogers, Benjamin H; Brown, Justin C; Gater, David R; Schmitz, Kathryn H

    2017-02-01

    To characterize the relationship between 1-repetition maximum (1-RM) bench press strength and isometric handgrip strength among breast cancer survivors. Cross-sectional study. Laboratory. Community-dwelling breast cancer survivors (N=295). Not applicable. 1-RM bench press strength was measured with a barbell and exercise bench. Isometric handgrip strength was measured using an isometric dynamometer, with 3 maximal contractions of the left and right hands. All measures were conducted by staff with training in clinical exercise testing. Among 295 breast cancer survivors, 1-RM bench press strength was 18.2±6.1kg (range, 2.2-43.0kg), and isometric handgrip strength was 23.5±5.8kg (range, 9.0-43.0kg). The strongest correlate of 1-RM bench press strength was the average isometric handgrip strength of both hands (r=.399; P<.0001). Mean difference analysis suggested that the average isometric handgrip strength of both hands overestimated 1-RM bench press strength by 4.7kg (95% limits of agreement, -8.2 to 17.6kg). In a multivariable linear regression model, the average isometric handgrip strength of both hands (β=.31; P<.0001) and age (β=-.20; P<.0001) were positively correlated with 1-RM bench press strength (R 2 =.23). Isometric handgrip strength is a poor surrogate for 1-RM bench press strength among breast cancer survivors. 1-RM bench press strength and isometric handgrip strength quantify distinct components of muscular strength. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  13. Evaluation of strength and conditioning measures with game success in Division I collegiate volleyball: A retrospective study.

    PubMed

    Bunn, Jennifer A; Ryan, Greg A; Button, Gabriel R; Zhang, S

    2017-08-04

    The purpose of this study was to retrospectively assess relationships between strength and conditioning (SC) measures and game performance in Division I volleyball. Five years of SC and game data were collected from one women's Division I collegiate team, n = 76. SC measures included: T-drill, 18.3 m sprint, back squat, hang clean, vertical jump, and broad jump. All game and SC stats were normalized to Z-scores. Analyses included assessing SC differences by position, and multiple stepwise regression to assess relationships between game and SC stats. There was a significant difference by position for broad jump (p =.002), 18.3 m sprint (p =.036), vertical (p <.001), and total strength (p =.019). Overall, game performance and SC measures were significantly correlated (r = .439, p <.001). Multiple regression analyses indicated significant relationships (p < .05) between SC measures and game success by position as follows: defensive specialist stats with squat and total strength; setters game stats with hang cleans, T-drill, and broad jump; pin hitter game stats with vertical, squat, and total strength; middle blockers game stats with broad jump. These data indicate that SC measures correlate well with game performance and are specific by position. These data could help SC coaches create a more precise training approach to focus on improving specific measures by position, which could then translate to improved game performance. These data could also help coaches with talent identification to determine playing time and rotations to maximize player ability and achieve success.

  14. Development of position measurement unit for flying inertial fusion energy target

    NASA Astrophysics Data System (ADS)

    Tsuji, R.; Endo, T.; Yoshida, H.; Norimatsu, T.

    2016-03-01

    We have reported the present status in the development of a position measurement unit (PMU) for a flying inertial fusion energy (IFE) target. The PMU, which uses Arago spot phenomena, is designed to have a measurement accuracy smaller than 1 μm. By employing divergent, pulsed orthogonal laser beam illumination, we can measure the time and the target position at the pulsed illumination. The two-dimensional Arago spot image is compressed into one-dimensional image by a cylindrical lens for real-time processing. The PMU are set along the injection path of the flying target. The local positions of the target in each PMU are transferred to the controller and analysed to calculate the target trajectory. Two methods are presented to calculate the arrival time and the arrival position of the target at the reactor centre.

  15. Fusion of radar and satellite target measurements

    NASA Astrophysics Data System (ADS)

    Moy, Gabriel; Blaty, Donald; Farber, Morton; Nealy, Carlton

    2011-06-01

    A potentially high payoff for the ballistic missile defense system (BMDS) is the ability to fuse the information gathered by various sensor systems. In particular, it may be valuable in the future to fuse measurements made using ground based radars with passive measurements obtained from satellite-based EO/IR sensors. This task can be challenging in a multitarget environment in view of the widely differing resolution between active ground-based radar and an observation made by a sensor at long range from a satellite platform. Additionally, each sensor system could have a residual pointing bias which has not been calibrated out. The problem is further compounded by the possibility that an EO/IR sensor may not see exactly the same set of targets as a microwave radar. In order to better understand the problems involved in performing the fusion of metric information from EO/IR satellite measurements with active microwave radar measurements, we have undertaken a study of this data fusion issue and of the associated data processing techniques. To carry out this analysis, we have made use of high fidelity simulations to model the radar observations from a missile target and the observations of the same simulated target, as gathered by a constellation of satellites. In the paper, we discuss the improvements seen in our tests when fusing the state vectors, along with the improvements in sensor bias estimation. The limitations in performance due to the differing phenomenology between IR and microwave radar are discussed as well.

  16. Erosion and strength degradation of biomorphic SiC.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martinez-Fernandez, J.; de Arellano-Lopez, A. R; Varela-Feria, F. M.

    2004-05-01

    Solid-particle-erosion studies were conducted on biomorphic SiC based on eucalyptus and pine, reaction-bonded (RB) SiC, and hot-pressed (HP) SiC. The erodents were angular SiC abrasives of average diameter 63, 143, or 390 {mu}m and the impact velocity was 100 m s{sup -1}. Impact occurred at normal incidence. Material loss in all targets occurred by brittle fracture. The biomorphic specimens eroded by formation of both lateral and radial cracks and their erosion rates were higher than both conventional SiCs. The RB SiC eroded as a classic brittle material, by formation and propagation of lateral cracks. The HP SiC, the hardest target,more » was the most erosion resistant. In erosion of the HP SiC, the abrasive particles, especially the largest ones, fragmented upon impact. The resulting dissipation of energy led to relatively low erosion rates. Flexural strength before and after erosion was measured for the biomorphic eucalyptus, RB SiC, and HP SiC. Erosion damage reduced the flexural strengths of all of the specimens. The relative strength reductions were lowest for the biomorphic eucalyptus and highest for the HP SiC. The hot-pressed SiC responded as predicted by accepted models of impact damage in brittle solids. The responses of the biomorphic and reaction-bonded SiC specimens were modeled as if they consisted of only SiC and porosity. This approximation agreed reasonably well with observed degradations of strength.« less

  17. Experimental evaluation of nonclassical correlations between measurement outcomes and target observable in a quantum measurement

    NASA Astrophysics Data System (ADS)

    Iinuma, Masataka; Suzuki, Yutaro; Nii, Taiki; Kinoshita, Ryuji; Hofmann, Holger F.

    2016-03-01

    In general, it is difficult to evaluate measurement errors when the initial and final conditions of the measurement make it impossible to identify the correct value of the target observable. Ozawa proposed a solution based on the operator algebra of observables which has recently been used in experiments investigating the error-disturbance trade-off of quantum measurements. Importantly, this solution makes surprisingly detailed statements about the relations between measurement outcomes and the unknown target observable. In the present paper, we investigate this relation by performing a sequence of two measurements on the polarization of a photon, so that the first measurement commutes with the target observable and the second measurement is sensitive to a complementary observable. While the initial measurement can be evaluated using classical statistics, the second measurement introduces the effects of quantum correlations between the noncommuting physical properties. By varying the resolution of the initial measurement, we can change the relative contribution of the nonclassical correlations and identify their role in the evaluation of the quantum measurement. It is shown that the most striking deviation from classical expectations is obtained at the transition between weak and strong measurements, where the competition between different statistical effects results in measurement values well outside the range of possible eigenvalues.

  18. 47 CFR 73.151 - Field strength measurements to establish performance of directional antennas.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... verified either by field strength measurement or by computer modeling and sampling system verification. (a... specifically identified by the Commission. (c) Computer modeling and sample system verification of modeled... performance verified by computer modeling and sample system verification. (1) A matrix of impedance...

  19. Comparison of measured and modeled BRDF of natural targets

    NASA Astrophysics Data System (ADS)

    Boucher, Yannick; Cosnefroy, Helene; Petit, Alain D.; Serrot, Gerard; Briottet, Xavier

    1999-07-01

    The Bidirectional Reflectance Distribution Function (BRDF) plays a major role to evaluate or simulate the signatures of natural and artificial targets in the solar spectrum. A goniometer covering a large spectral and directional domain has been recently developed by the ONERA/DOTA. It was designed to allow both laboratory and outside measurements. The spectral domain ranges from 0.40 to 0.95 micrometer, with a resolution of 3 nm. The geometrical domain ranges 0 - 60 degrees for the zenith angle of the source and the sensor, and 0 - 180 degrees for the relative azimuth between the source and the sensor. The maximum target size for nadir measurements is 22 cm. The spatial target irradiance non-uniformity has been evaluated and then used to correct the raw measurements. BRDF measurements are calibrated thanks to a spectralon reference panel. Some BRDF measurements performed on sand and short grass and are presented here. Eight bidirectional models among the most popular models found in the literature have been tested on these measured data set. A code fitting the model parameters to the measured BRDF data has been developed. The comparative evaluation of the model performances is carried out, versus different criteria (root mean square error, root mean square relative error, correlation diagram . . .). The robustness of the models is evaluated with respect to the number of BRDF measurements, noise and interpolation.

  20. Measurements to predict the time of target replacement of a helical tomotherapy.

    PubMed

    Kampfer, Severin; Schell, Stefan; Duma, Marciana N; Wilkens, Jan J; Kneschaurek, Peter

    2011-11-15

    Intensity-modulated radiation therapy (IMRT) requires more beam-on time than normal open field treatment. Consequently, the machines wear out and need more spare parts. A helical tomotherapy treatment unit needs a periodical tungsten target replacement, which is a time consuming event. To be able to predict the next replacement would be quite valuable. We observed unexpected variations towards the end of the target lifetime in the performed pretreatment measurements for patient plan verification. Thus, we retrospectively analyze the measurements of our quality assurance program. The time dependence of the quotient of two simultaneous dose measurements at different depths within a phantom for a fixed open field irradiation is evaluated. We also assess the time-dependent changes of an IMRT plan measurement and of a relative depth dose curve measurement. Additionally, we performed a Monte Carlo simulation with Geant4 to understand the physical reasons for the measured values. Our measurements show that the dose at a specified depth compared to the dose in shallower regions of the phantom declines towards the end of the target lifetime. This reproducible effect can be due to the lowering of the mean energy of the X-ray spectrum. These results are supported by the measurements of the IMRT plan, as well as the study of the relative depth dose curve. Furthermore, the simulation is consistent with these findings since it provides a possible explanation for the reduction of the mean energy for thinner targets. It could be due to the lowering of low energy photon self-absorption in a worn out and therefore thinner target. We state a threshold value for our measurement at which a target replacement should be initiated. Measurements to observe a change in the energy are good predictors of the need for a target replacement. However, since all results support the softening of the spectrum hypothesis, all depth-dependent setups are viable for analyzing the deterioration of the

  1. A measurement of the vibrational band strength for the v3 band of the HO2 radical

    NASA Technical Reports Server (NTRS)

    Zahniser, M. S.; Stanton, A. C.

    1984-01-01

    Laboratory measurements of the v(3) band strength of HO2 using a tunable diode laser to measure the absorption strength of a vibration-rotation line in the P branch near 1080/cm are reported. The HO2 is generated in a discharge-flow system by reaction of fluorine atoms with excess H2O2: F + H2O2 - HO2 + HF. The HO2 concentration is determined from measurements of F-atom concentrations using both chemical titration with Cl2 and tunable diode laser absorption by the F-atom spin-orbit transition near 404/cm. The experimental data are consistent with a value of k(3) = (1.6 + or - 0.3) x 10 to the 12th cu cm/s and a ratio k(4)/k(1) = 1.0 + or - 0.4. The line strength for the 6(15) - 7(16)F(1) transition is 2.9 x 10 to the -21 sq cm/molecule/cm, which corresponds to a v(3) band strength of 35 + or - 9/sq cm/(STP atm). This value is a factor of 1.6 to 6 lower than previous ab initio calculations.

  2. Human adaptations for the visual assessment of strength and fighting ability from the body and face

    PubMed Central

    Sell, Aaron; Cosmides, Leda; Tooby, John; Sznycer, Daniel; von Rueden, Christopher; Gurven, Michael

    2008-01-01

    Selection in species with aggressive social interactions favours the evolution of cognitive mechanisms for assessing physical formidability (fighting ability or resource-holding potential). The ability to accurately assess formidability in conspecifics has been documented in a number of non-human species, but has not been demonstrated in humans. Here, we report tests supporting the hypothesis that the human cognitive architecture includes mechanisms that assess fighting ability—mechanisms that focus on correlates of upper-body strength. Across diverse samples of targets that included US college students, Bolivian horticulturalists and Andean pastoralists, subjects in the US were able to accurately estimate the physical strength of male targets from photos of their bodies and faces. Hierarchical linear modelling shows that subjects were extracting cues of strength that were largely independent of height, weight and age, and that corresponded most strongly to objective measures of upper-body strength—even when the face was all that was available for inspection. Estimates of women's strength were less accurate, but still significant. These studies are the first empirical demonstration that, for humans, judgements of strength and judgements of fighting ability not only track each other, but accurately track actual upper-body strength. PMID:18945661

  3. SME filter approach to multiple target tracking with false and missing measurements

    NASA Astrophysics Data System (ADS)

    Lee, Yong J.; Kamen, Edward W.

    1993-10-01

    The symmetric measurement equation (SME) filter for track maintenance in multiple target tracking is extended to the general case when there are an arbitrary unknown number of false and missing position measurements in the measurement set at any time point. It is assumed that the number N of targets is known a priori and that the target motions consist of random perturbations of constant-velocity trajectories. The key idea in the paper is to generate a new measurement vector from sums-of-products of the elements of 'feasible' N-element data vectors that pass a thresholding operation in the sums-of-products framework. Via this construction, the data association problem is completely avoided, and in addition, there is no need to identify which target measurements may correspond to false returns or which target measurements may be missing. A computer simulation of SME filter performance is given, including a comparison with the associated filter (a benchmark) and the joint probabilistic data association (JPDA) filter.

  4. Lifetime measurements and oscillator strengths in singly ionized scandium and the solar abundance of scandium

    NASA Astrophysics Data System (ADS)

    Pehlivan Rhodin, A.; Belmonte, M. T.; Engström, L.; Lundberg, H.; Nilsson, H.; Hartman, H.; Pickering, J. C.; Clear, C.; Quinet, P.; Fivet, V.; Palmeri, P.

    2017-12-01

    The lifetimes of 17 even-parity levels (3d5s, 3d4d, 3d6s and 4p2) in the region 57 743-77 837 cm-1 of singly ionized scandium (Sc II) were measured by two-step time-resolved laser induced fluorescence spectroscopy. Oscillator strengths of 57 lines from these highly excited upper levels were derived using a hollow cathode discharge lamp and a Fourier transform spectrometer. In addition, Hartree-Fock calculations where both the main relativistic and core-polarization effects were taken into account were carried out for both low- and high-excitation levels. There is a good agreement for most of the lines between our calculated branching fractions and the measurements of Lawler & Dakin in the region 9000-45 000 cm-1 for low excitation levels and with our measurements for high excitation levels in the region 23 500-63 100 cm-1. This, in turn, allowed us to combine the calculated branching fractions with the available experimental lifetimes to determine semi-empirical oscillator strengths for a set of 380 E1 transitions in Sc II. These oscillator strengths include the weak lines that were used previously to derive the solar abundance of scandium. The solar abundance of scandium is now estimated to logε⊙ = 3.04 ± 0.13 using these semi-empirical oscillator strengths to shift the values determined by Scott et al. The new estimated abundance value is in agreement with the meteoritic value (logεmet = 3.05 ± 0.02) of Lodders, Palme & Gail.

  5. Where did my wifi go? Measuring soil moisture using wifi signal strength

    NASA Astrophysics Data System (ADS)

    Hut, Rolf; de Jeu, Richard

    2015-04-01

    Soil moisture is tricky to measure. Currently soil moisture is measured at small footprints using probes and other field devices, or at large footprints using satellites. Promising developments in measuring soil moisture are using fiber optic cables for measurements along a line, or using cosmos rays for field scale measurements. In this demonstration we present a low cost alternative to measure soil moisture at footprints of a few square meters. We use a wifi hotspot and a wifi dongle, both mounted in a cantenna for beam forming. We aim the hotspot on a piece of soil and put the dongle in the path of the reflection. By logging the signal strength of the wifi netwerk, we have a proxy for soil moisture. A first proof of concept is presented.

  6. Relationships between Isometric Muscle Strength, Gait Parameters, and Gross Motor Function Measure in Patients with Cerebral Palsy.

    PubMed

    Shin, Hyung Ik; Sung, Ki Hyuk; Chung, Chin Youb; Lee, Kyoung Min; Lee, Seung Yeol; Lee, In Hyeok; Park, Moon Seok

    2016-01-01

    This study investigated the correlation between isometric muscle strength, gross motor function, and gait parameters in patients with spastic cerebral palsy and to find which muscle groups play an important role for gait pattern in a flexed knee gait. Twenty-four ambulatory patients (mean age, 10.0 years) with spastic cerebral palsy who were scheduled for single event multilevel surgery, including distal hamstring lengthening, were included. Preoperatively, peak isometric muscle strength was measured for the hip flexor, hip extensor, knee flexor, and knee extensor muscle groups using a handheld dynamometer, and three-dimensional (3D) gait analysis and gross motor function measure (GMFM) scoring were also performed. Correlations between peak isometric strength and GMFM, gait kinematics, and gait kinetics were analyzed. Peak isometric muscle strength of all muscle groups was not related to the GMFM score and the gross motor function classification system level. Peak isometric strength of the hip extensor and knee extensor was significantly correlated with the mean pelvic tilt (r=-0.588, p=0.003 and r=-0.436, p=0.033) and maximum pelvic obliquity (r=-0.450, p=0.031 and r=-0.419, p=0.041). There were significant correlations between peak isometric strength of the knee extensor and peak knee extensor moment in early stance (r=0.467, p=0.021) and in terminal stance (r=0.416, p=0.043). There is no correlation between muscle strength and gross motor function. However, this study showed that muscle strength, especially of the extensor muscle group of the hip and knee joints, might play a critical role in gait by stabilizing pelvic motion and decreasing energy consumption in a flexed knee gait.

  7. Reliability of the hand held dynamometer in measuring muscle strength in people with interstitial lung disease.

    PubMed

    Dowman, Leona; McDonald, Christine F; Hill, Catherine J; Lee, Annemarie; Barker, Kathryn; Boote, Claire; Glaspole, Ian; Goh, Nicole; Southcott, Annemarie; Burge, Angela; Ndongo, Rebecca; Martin, Alicia; Holland, Anne E

    2016-09-01

    To evaluate the inter-rater and intra-rater reliability of the hand held dynamometer in measuring muscle strength in people with interstitial lung disease (ILD). Test retest reliability of hand-held dynamometry for elbow flexor and knee extensor strength between two independent raters and two testing sessions. Physiotherapy department within a tertiary hospital. Thirty participants with ILD of varying aetiology were included. Twenty participants completed the inter-rater reliability protocol (10 idiopathic pulmonary fibrosis, mean (SD) age 73 (10) years, 11 male) and 21 participants completed the intra-rater reliability protocol (10 idiopathic pulmonary fibrosis, mean age 71 (10) years, 11 male). Mean muscle strength (kg). Agreement between the two raters and testing sessions was analyzed using Bland-Altman plots and reliability was estimated using intraclass correlation coefficients (ICC). For elbow flexor strength there was a mean difference between raters of -0.6kg (limits of agreement (LOA) -5.6 to 4.4kg) and within raters of -0.3kg (LOA -2.8 to 2.3kg). The ICCs were 0.95 and 0.98, respectively. For knee extensor strength there was a mean difference between raters of -1.5kg (LOA -6.9 to 3.9kg) and within raters of -0.7kg (LOA -3.9 to 2.4kg). The ICCs were 0.95 and 0.97, respectively. Hand-held dynamometry is reliable in measuring elbow flexor and knee extensor strength in people with ILD. Copyright © 2015 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  8. Objectively measured physical activity and bone strength in 9-year-old boys and girls.

    PubMed

    Sardinha, Luís B; Baptista, Fátima; Ekelund, Ulf

    2008-09-01

    The purpose of this work was to analyze the relationship between intensity and duration of physical activity and composite indices of femoral neck strength and bone-mineral content of the femoral neck, lumbar spine, and total body. Physical activity was assessed by accelerometry in 143 girls and 150 boys (mean age: 9.7 years). Measurement of bone-mineral content, femoral neck bone-mineral density, femoral neck width, hip axis length, and total body fat-free mass was performed with dual-energy radiograph absorptiometry. Compressive [(bone-mineral density x femoral neck width/weight)] and bending strength [(bone-mineral density x femoral neck width(2))/(hip axis length x weight)] express the forces that the femoral neck has to withstand in weight bearing, whereas impact strength [(bone-mineral density x femoral neck width x hip axis length)/(height x weight)] expresses the energy that the femoral neck has to absorb in an impact from standing height. Analysis of covariance (fat-free mass and age adjusted) showed differences between boys and girls of approximately 9% for compressive, 10% for bending, and 9% for impact strength. Stepwise regression analysis using time spent at sedentary, light, moderate, and vigorous physical activity as predictors revealed that vigorous physical activity explained 5% to 9% of femoral neck strength variable variance in both genders, except for bending strength in boys, and approximately 1% to 3% of total body and femoral neck bone-mineral content variance. Vigorous physical activity was then used to categorize boys and girls into quartiles. Pairwise comparison indicated that boys in the third and fourth quartiles (accumulation of >26 minutes/day) demonstrated higher compressive (11%-12%), bending (10%), and impact (14%) strength than boys in the first quartile. In girls, comparison revealed a difference between the fourth (accumulation of >25 minutes/day) and first quartiles for bending strength (11%). We did not observe any

  9. Measures of functional performance and their association with hip and thigh strength.

    PubMed

    Kollock, Roger; Van Lunen, Bonnie L; Ringleb, Stacie I; Oñate, James A

    2015-01-01

    Insufficient hip and thigh strength may increase an athlete's susceptibility to injury. However, screening for strength deficits using isometric and isokinetic instrumentation may not be practical in all clinical scenarios. To determine if functional performance tests are valid indicators of hip and thigh strength. Descriptive laboratory study. Research laboratory. Sixty-two recreationally athletic men (n = 30, age = 21.07 years, height = 173.84 cm, mass = 81.47 kg) and women (n = 32, age = 21.03 years, height = 168.77 cm, mass = 68.22 kg) participants were recruited. During session 1, we measured isometric peak force and rate of force development for 8 lower extremity muscle groups, followed by an isometric endurance test. During session 2, participants performed functional performance tests. Peak force, rate of force development, fatigue index, hop distance (or height), work (joules), and number of hops performed during the 30-second lateral-hop test were assessed. The r values were squared to calculate r (2). We used Pearson correlations to evaluate the associations between functional performance and strength. In men, the strongest relationship was observed between triple-hop work and hip-adductor peak force (r(2) = 50, P ≤ .001). Triple-hop work also was related to hip-adductor (r(2) = 38, P ≤ .01) and hip-flexor (r(2) = 37, P ≤ .01) rate of force development. For women, the strongest relationships were between single-legged vertical-jump work and knee-flexor peak force (r(2) = 0.44, P ≤ .01) and single-legged vertical-jump height and knee-flexor peak force (r(2) = 0.42, P ≤ .01). Single-legged vertical-jump height also was related to knee-flexor rate of force development (r(2) = 0.49, P ≤ .001). The 30-second lateral-hop test did not account for a significant portion of the variance in strength endurance. Hop tests alone did not provide clinicians with enough information to make evidence-based decisions about lower extremity strength in isolated

  10. Cone Penetrometer Shear Strength Measurements of Sludge Waste in Tanks 241-AN-101 and 241-AN-106

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Follett, Jordan R.

    2014-03-06

    This document presents the resulting shear strength profiles for sludge waste in Tanks 241-AN-101 and 241-AN-106, as determined with a full-flow cone penetrometer. Full-flow penetrometer measurements indicate shear strength profiles that increase roughly uniformly with depth. For Tank 241-AN-101, the undrained shear strength was calculated to range from 500 Pa near the sludge surface to roughly 3,300 Pa at 15 inches above the tank bottom. For 241-AN-106, the undrained shear strength was calculated to range from 500 Pa near the sludge surface to roughly 5,000 Pa at 15 inches above the tank bottom.

  11. Developing the elastic modulus measurement of asphalt concrete using the compressive strength test

    NASA Astrophysics Data System (ADS)

    Setiawan, Arief; Suparma, Latif Budi; Mulyono, Agus Taufik

    2017-11-01

    Elastic modulus is a fundamental property of an asphalt mixture. An analytical method of the elastic modulus is needed to determine the thickness of flexible pavement. It has a role as one of the input values on a stress-strain analysis in the finite element method. The aim of this study was to develop the measurement of the elastic modulus by using compressive strength testing. This research used a set of specimen mold tool and Delta Dimensi software to record strain changes occurring in the proving ring of compression machine and the specimens. The elastic modulus of the five types of aggregate gradation and 2 types of asphalt were measured at optimum asphalt content. Asphalt Cement 60/70 and Elastomer Modified Asphalt (EMA) were used as a binder. Manufacturing success indicators of the specimens used void-in-the-mix (VIM) 3-5 % criteria. The success rate of the specimen manufacturing was more than 76%. Thus, the procedure and the compressive strength test equipment could be used for the measurement of the elastic modulus. The aggregate gradation and asphalt types significantly affected the elastic modulus of the asphalt concrete.

  12. Correlation of cervical endplate strength with CT measured subchondral bone density

    PubMed Central

    Ordway, Nathaniel R.; Lu, Yen-Mou; Zhang, Xingkai; Cheng, Chin-Chang; Fang, Huang

    2007-01-01

    Cervical interbody device subsidence can result in screw breakage, plate dislodgement, and/or kyphosis. Preoperative bone density measurement may be helpful in predicting the complications associated with anterior cervical surgery. This is especially important when a motion preserving device is implanted given the detrimental effect of subsidence on the postoperative segmental motion following disc replacement. To evaluate the structural properties of the cervical endplate and examine the correlation with CT measured trabecular bone density. Eight fresh human cadaver cervical spines (C2–T1) were CT scanned and the average trabecular bone densities of the vertebral bodies (C3–C7) were measured. Each endplate surface was biomechanically tested for regional yield load and stiffness using an indentation test method. Overall average density of the cervical vertebral body trabecular bone was 270 ± 74 mg/cm3. There was no significant difference between levels. The yield load and stiffness from the indentation test of the endplate averaged 139 ± 99 N and 156 ± 52 N/mm across all cervical levels, endplate surfaces, and regional locations. The posterior aspect of the endplate had significantly higher yield load and stiffness in comparison to the anterior aspect and the lateral aspect had significantly higher yield load in comparison to the midline aspect. There was a significant correlation between the average yield load and stiffness of the cervical endplate and the trabecular bone density on regression analysis. Although there are significant regional variations in the endplate structural properties, the average of the endplate yield loads and stiffnesses correlated with the trabecular bone density. Given the morbidity associated with subsidence of interbody devices, a reliable and predictive method of measuring endplate strength in the cervical spine is required. Bone density measures may be used preoperatively to assist in the prediction of the strength

  13. Toward predicting tensile strength of pharmaceutical tablets by ultrasound measurement in continuous manufacturing.

    PubMed

    Razavi, Sonia M; Callegari, Gerardo; Drazer, German; Cuitiño, Alberto M

    2016-06-30

    An ultrasound measurement system was employed as a non-destructive method to evaluate its reliability in predicting the tensile strength of tablets and investigate the benefits of incorporating it in a continuous line, manufacturing solid dosage forms. Tablets containing lactose, acetaminophen, and magnesium stearate were manufactured continuously and in batches. The effect of two processing parameters, compaction force and level of shear strain were examined. Young's modulus and tensile strength of tablets were obtained by ultrasound and diametrical mechanical testing, respectively. It was found that as the blend was exposed to increasing levels of shear strain, the speed of sound in the tablets decreased and the tablets became both softer and mechanically weaker. Moreover, the results indicate that two separate tablet material properties (e.g., relative density and Young's modulus) are necessary in order to predict tensile strength. A strategy for hardness prediction is proposed that uses the existing models for Young's modulus and tensile strength of porous materials. Ultrasound testing was found to be very sensitive in differentiating tablets with similar formulation but produced under different processing conditions (e.g., different level of shear strain), thus, providing a fast, and non-destructive method for hardness prediction that could be incorporated to a continuous manufacturing process. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Faster diffraction-based overlay measurements with smaller targets using 3D gratings

    NASA Astrophysics Data System (ADS)

    Li, Jie; Kritsun, Oleg; Liu, Yongdong; Dasari, Prasad; Volkman, Catherine; Hu, Jiangtao

    2012-03-01

    Diffraction-based overlay (DBO) technologies have been developed to address the overlay metrology challenges for 22nm technology node and beyond. Most DBO technologies require specially designed targets that consist of multiple measurement pads, which consume too much space and increase measurement time. The traditional empirical approach (eDBO) using normal incidence spectroscopic reflectometry (NISR) relies on linear response of the reflectance with respect to overlay displacement within a small range. It offers convenience of quick recipe setup since there is no need to establish a model. However it requires three or four pads per direction (x or y) which adds burden to throughput and target size. Recent advances in modeling capability and computation power enabled mDBO, which allows overlay measurement with reduced number of pads, thus reducing measurement time and DBO target space. In this paper we evaluate the performance of single pad mDBO measurements using two 3D targets that have different grating shapes: squares in boxes and L-shapes in boxes. Good overlay sensitivities are observed for both targets. The correlation to programmed shifts and image-based overlay (IBO) is excellent. Despite the difference in shapes, the mDBO results are comparable for square and L-shape targets. The impact of process variations on overlay measurements is studied using a focus and exposure matrix (FEM) wafer. Although the FEM wafer has larger process variations, the correlation of mDBO results with IBO measurements is as good as the normal process wafer. We demonstrate the feasibility of single pad DBO measurements with faster throughput and smaller target size, which is particularly important in high volume manufacturing environment.

  15. Relationships between Isometric Muscle Strength, Gait Parameters, and Gross Motor Function Measure in Patients with Cerebral Palsy

    PubMed Central

    Shin, Hyung-Ik; Sung, Ki Hyuk; Chung, Chin Youb; Lee, Kyoung Min; Lee, Seung Yeol; Lee, In Hyeok

    2016-01-01

    Purpose This study investigated the correlation between isometric muscle strength, gross motor function, and gait parameters in patients with spastic cerebral palsy and to find which muscle groups play an important role for gait pattern in a flexed knee gait. Materials and Methods Twenty-four ambulatory patients (mean age, 10.0 years) with spastic cerebral palsy who were scheduled for single event multilevel surgery, including distal hamstring lengthening, were included. Preoperatively, peak isometric muscle strength was measured for the hip flexor, hip extensor, knee flexor, and knee extensor muscle groups using a handheld dynamometer, and three-dimensional (3D) gait analysis and gross motor function measure (GMFM) scoring were also performed. Correlations between peak isometric strength and GMFM, gait kinematics, and gait kinetics were analyzed. Results Peak isometric muscle strength of all muscle groups was not related to the GMFM score and the gross motor function classification system level. Peak isometric strength of the hip extensor and knee extensor was significantly correlated with the mean pelvic tilt (r=-0.588, p=0.003 and r=-0.436, p=0.033) and maximum pelvic obliquity (r=-0.450, p=0.031 and r=-0.419, p=0.041). There were significant correlations between peak isometric strength of the knee extensor and peak knee extensor moment in early stance (r=0.467, p=0.021) and in terminal stance (r=0.416, p=0.043). Conclusion There is no correlation between muscle strength and gross motor function. However, this study showed that muscle strength, especially of the extensor muscle group of the hip and knee joints, might play a critical role in gait by stabilizing pelvic motion and decreasing energy consumption in a flexed knee gait. PMID:26632404

  16. Comparison of Rising Resonator Relative Permittivity Measurements to Ground Penetrating Radar Data

    DTIC Science & Technology

    2014-04-01

    permittivity of the soil and the target is critical in determining the strength of the reflection from the target. In this paper, a microstrip ring resonator...is used to measure the relative permittivity of the soil and various target fill materials. For this measurement technique, a microstrip ring... antennas of varying frequencies to take measurements of the two port transmission coefficient. This coefficient is measured from the input feedline to

  17. Comparison of Ring Resonator Relative Permittivity Measurements to Ground Penetrating Radar Data

    DTIC Science & Technology

    2014-04-01

    permittivity of the soil and the target is critical in determining the strength of the reflection from the target. In this paper, a microstrip ring resonator...is used to measure the relative permittivity of the soil and various target fill materials. For this measurement technique, a microstrip ring... antennas of varying frequencies to take measurements of the two port transmission coefficient. This coefficient is measured from the input feedline to

  18. Bias estimation for moving optical sensor measurements with targets of opportunity

    NASA Astrophysics Data System (ADS)

    Belfadel, Djedjiga; Osborne, Richard W.; Bar-Shalom, Yaakov

    2014-06-01

    Integration of space based sensors into a Ballistic Missile Defense System (BMDS) allows for detection and tracking of threats over a larger area than ground based sensors [1]. This paper examines the effect of sensor bias error on the tracking quality of a Space Tracking and Surveillance System (STSS) for the highly non-linear problem of tracking a ballistic missile. The STSS constellation consists of two or more satellites (on known trajectories) for tracking ballistic targets. Each satellite is equipped with an IR sensor that provides azimuth and elevation to the target. The tracking problem is made more difficult due to a constant or slowly varying bias error present in each sensor's line of sight measurements. It is important to correct for these bias errors so that the multiple sensor measurements and/or tracks can be referenced as accurately as possible to a common tracking coordinate system. The measurements provided by these sensors are assumed time-coincident (synchronous) and perfectly associated. The line of sight (LOS) measurements from the sensors can be fused into measurements which are the Cartesian target position, i.e., linear in the target state. We evaluate the Cramér-Rao Lower Bound (CRLB) on the covariance of the bias estimates, which serves as a quantification of the available information about the biases. Statistical tests on the results of simulations show that this method is statistically efficient, even for small sample sizes (as few as two sensors and six points on the (unknown) trajectory of a single target of opportunity). We also show that the RMS position error is significantly improved with bias estimation compared with the target position estimation using the original biased measurements.

  19. Measurement of plasma momentum exerted on target by a small helicon plasma thruster and comparison with direct thrust measurement.

    PubMed

    Takahashi, Kazunori; Komuro, Atsushi; Ando, Akira

    2015-02-01

    Momentum, i.e., force, exerted from a small helicon plasma thruster to a target plate is measured simultaneously with a direct thrust measurement using a thrust balance. The calibration coefficient relating a target displacement to a steady-state force is obtained by supplying a dc to a calibration coil mounted on the target, where a force acting to a small permanent magnet located near the coil is directly measured by using a load cell. As the force exerted by the plasma flow to the target plate is in good agreement with the directly measured thrust, the validity of the target technique is demonstrated under the present operating conditions, where the thruster is operated in steady-state. Furthermore, a calibration coefficient relating a swing amplitude of the target to an impulse bit is also obtained by pulsing the calibration coil current. The force exerted by the pulsed plasma, which is estimated from the measured impulse bit and the pulse width, is also in good agreement with that obtained for the steady-state operation; hence, the thrust assessment of the helicon plasma thruster by the target is validated for both the steady-state and pulsed operations.

  20. Autonomous target recognition using remotely sensed surface vibration measurements

    NASA Astrophysics Data System (ADS)

    Geurts, James; Ruck, Dennis W.; Rogers, Steven K.; Oxley, Mark E.; Barr, Dallas N.

    1993-09-01

    The remotely measured surface vibration signatures of tactical military ground vehicles are investigated for use in target classification and identification friend or foe (IFF) systems. The use of remote surface vibration sensing by a laser radar reduces the effects of partial occlusion, concealment, and camouflage experienced by automatic target recognition systems using traditional imagery in a tactical battlefield environment. Linear Predictive Coding (LPC) efficiently represents the vibration signatures and nearest neighbor classifiers exploit the LPC feature set using a variety of distortion metrics. Nearest neighbor classifiers achieve an 88 percent classification rate in an eight class problem, representing a classification performance increase of thirty percent from previous efforts. A novel confidence figure of merit is implemented to attain a 100 percent classification rate with less than 60 percent rejection. The high classification rates are achieved on a target set which would pose significant problems to traditional image-based recognition systems. The targets are presented to the sensor in a variety of aspects and engine speeds at a range of 1 kilometer. The classification rates achieved demonstrate the benefits of using remote vibration measurement in a ground IFF system. The signature modeling and classification system can also be used to identify rotary and fixed-wing targets.

  1. Isometric hand grip strength measured by the Nintendo Wii Balance Board - a reliable new method.

    PubMed

    Blomkvist, A W; Andersen, S; de Bruin, E D; Jorgensen, M G

    2016-02-03

    Low hand grip strength is a strong predictor for both long-term and short-term disability and mortality. The Nintendo Wii Balance Board (WBB) is an inexpensive, portable, wide-spread instrument with the potential for multiple purposes in assessing clinically relevant measures including muscle strength. The purpose of the study was to explore intrarater reliability and concurrent validity of the WBB by comparing it to the Jamar hand dynamometer. Intra-rater test-retest cohort design with randomized validity testing on the first session. Using custom WBB software, thirty old adults (69.0 ± 4.2 years of age) were studied for reproducibility and concurrent validity compared to the Jamar hand dynamometer. Reproducibility was tested for dominant and non-dominant hands during the same time-of-day, one week apart. Intraclass correlation coefficient (ICC) and standard error of measurement (SEM) and limits of agreement (LOA) were calculated to describe relative and absolute reproducibility respectively. To describe concurrent validity, Pearson's product-moment correlation and ICC was calculated. Reproducibility was high with ICC values of >0.948 across all measures. Both SEM and LOA were low (0.2-0.5 kg and 2.7-4.2 kg, respectively) in both the dominant and non-dominant hand. For validity, Pearson correlations were high (0.80-0.88) and ICC values were fair to good (0.763-0.803). Reproducibility for WBB was high for relative measures and acceptable for absolute measures. In addition, concurrent validity between the Jamar hand dynamometer and the WBB was acceptable. Thus, the WBB may be a valid instrument to assess hand grip strength in older adults.

  2. An X-ray monitor for measurement of a titanium tritide target thickness

    NASA Technical Reports Server (NTRS)

    Alger, D. L.; Steinberg, R.

    1972-01-01

    An X-ray device capable of measuring titanium tritide film thickness from 0.1 to 30 micrometers has been built and tested. The monitor was designed for use in a rotating target system which used thick targets and incorporated a sputtering electrode to remove depleted layers from the target surface. The thickness measurement can be done in the presence of an intense background of bremsstrahlung and characteristic titanium X-radiation. A measurement can be accomplished in situ in two hours with reasonable accuracy.

  3. An infrared small target detection method based on multiscale local homogeneity measure

    NASA Astrophysics Data System (ADS)

    Nie, Jinyan; Qu, Shaocheng; Wei, Yantao; Zhang, Liming; Deng, Lizhen

    2018-05-01

    Infrared (IR) small target detection plays an important role in the field of image detection area owing to its intrinsic characteristics. This paper presents a multiscale local homogeneity measure (MLHM) for infrared small target detection, which can enhance the performance of IR small target detection system. Firstly, intra-patch homogeneity of the target itself and the inter-patch heterogeneity between target and the local background regions are integrated to enhance the significant of small target. Secondly, a multiscale measure based on local regions is proposed to obtain the most appropriate response. Finally, an adaptive threshold method is applied to small target segmentation. Experimental results on three different scenarios indicate that the MLHM has good performance under the interference of strong noise.

  4. Testing Measurement Invariance in the Target Rotated Multigroup Exploratory Factor Model

    ERIC Educational Resources Information Center

    Dolan, Conor V.; Oort, Frans J.; Stoel, Reinoud D.; Wicherts, Jelte M.

    2009-01-01

    We propose a method to investigate measurement invariance in the multigroup exploratory factor model, subject to target rotation. We consider both oblique and orthogonal target rotation. This method has clear advantages over other approaches, such as the use of congruence measures. We demonstrate that the model can be implemented readily in the…

  5. A Novel Detection Method for Underwater Moving Targets by Measuring Their ELF Emissions with Inductive Sensors

    PubMed Central

    Li, Bin; Chen, Lianping; Li, Li

    2017-01-01

    In this article, we propose a novel detection method for underwater moving targets by detecting their extremely low frequency (ELF) emissions with inductive sensors. The ELF field source of the targets is modeled by a horizontal electric dipole at distances more than several times of the targets’ length. The formulas for the fields produced in air are derived with a three-layer model (air, seawater and seafloor) and are evaluated with a complementary numerical integration technique. A proof of concept measurement is presented. The ELF emissions from a surface ship were detected by inductive electronic and magnetic sensors as the ship was leaving a harbor. ELF signals are of substantial strength and have typical characteristic of harmonic line spectrum, and the fundamental frequency has a direct relationship with the ship’s speed. Due to the high sensitivity and low noise level of our sensors, it is capable of resolving weak ELF signals at long distance. In our experiment, a detection distance of 1300 m from the surface ship above the sea surface was realized, which shows that this method would be an appealing complement to the usual acoustic detection and magnetic anomaly detection capability. PMID:28788097

  6. Region of Interest Correction Factors Improve Reliability of Diffusion Imaging Measures Within and Across Scanners and Field Strengths

    PubMed Central

    Venkatraman, Vijay K; Gonzalez, Christopher E.; Landman, Bennett; Goh, Joshua; Reiter, David A.; An, Yang; Resnick, Susan M.

    2017-01-01

    Diffusion tensor imaging (DTI) measures are commonly used as imaging markers to investigate individual differences in relation to behavioral and health-related characteristics. However, the ability to detect reliable associations in cross-sectional or longitudinal studies is limited by the reliability of the diffusion measures. Several studies have examined reliability of diffusion measures within (i.e. intra-site) and across (i.e. inter-site) scanners with mixed results. Our study compares the test-retest reliability of diffusion measures within and across scanners and field strengths in cognitively normal older adults with a follow-up interval less than 2.25 years. Intra-class correlation (ICC) and coefficient of variation (CoV) of fractional anisotropy (FA) and mean diffusivity (MD) were evaluated in sixteen white matter and twenty-six gray matter bilateral regions. The ICC for intra-site reliability (0.32 to 0.96 for FA and 0.18 to 0.95 for MD in white matter regions; 0.27 to 0.89 for MD and 0.03 to 0.79 for FA in gray matter regions) and inter-site reliability (0.28 to 0.95 for FA in white matter regions, 0.02 to 0.86 for MD in gray matter regions) with longer follow-up intervals were similar to earlier studies using shorter follow-up intervals. The reliability of across field strengths comparisons was lower than intra- and inter-site reliability. Within and across scanner comparisons showed that diffusion measures were more stable in larger white matter regions (> 1500 mm3). For gray matter regions, the MD measure showed stability in specific regions and was not dependent on region size. Linear correction factor estimated from cross-sectional or longitudinal data improved the reliability across field strengths. Our findings indicate that investigations relating diffusion measures to external variables must consider variable reliability across the distinct regions of interest and that correction factors can be used to improve consistency of measurement across

  7. Decline in measured glomerular filtration rate is associated with a decrease in endurance, strength, balance and fine motor skills.

    PubMed

    Hellberg, Matthias; Höglund, Peter; Svensson, Philippa; Abdulahi, Huda; Clyne, Naomi

    2017-07-01

    Physical performance in chronic kidney disease affects morbidity and mortality. The aim was to find out which measures of physical performance are important in chronic kidney disease (CKD) and if there are associations with declining measured glomerular filtration rate (GFR). Endurance was assessed by 6 min walk test (6-MWT) and stair climbing, muscular endurance by 30 s sit to stand, heel rises and toe lifts, strength by quadriceps- and handgrip-strength, balance by functional reach and Berg's balance scale, and fine motor skills by Moberg's picking-up test. GFR was measured by Iohexol clearance. The study comprised 101 patients with CKD 3b-5 not started dialysis, 40 women and 61 men, with a mean age of 67 ± 13 (range: 22 - 87) years. All measures of physical performance were impaired. A decrease in GFR of 10 mL/min per 1.73 m 2 corresponded to a 35 metre shorter walking distance in the 6-MWT. Multivariable linear regression analysis showed significant relationships between decline in GFR and the 6-MWT (P = 0.04), isometric quadriceps strength left (P = 0.04), balance measured as functional reach (P = 0.02) and fine motor skills in the left hand as measured by Moberg's picking-up test (P = 0.01), respectively, after sex, age, comorbidity and the interaction between sex and age had been taken into account. Endurance, muscular endurance, strength, balance and fine motor skills were impaired in patients with CKD 3b-5. Walking capacity, isometric quadriceps strength, balance, and fine motor skills were associated with declining GFR. The left extremities were more susceptible to GFR, ageing and comorbidities and seem thus to be more sensitive. © 2016 Asian Pacific Society of Nephrology.

  8. The validity and reliability of the Functional Strength Measurement (FSM) in children with intellectual disabilities.

    PubMed

    Aertssen, W F M; Steenbergen, B; Smits-Engelsman, B C M

    2018-06-07

    There is lack of valid and reliable field-based tests for assessing functional strength in young children with mild intellectual disabilities (IDs). The aim of this study was to investigate the test-retest reliability and construct validity of the Functional Strength Measurement in children with ID (FSM-ID). Fifty-two children with mild ID (40 boys and 12 girls, mean age 8.48 years, SD = 1.48) were tested with the FSM. Test-retest reliability (n = 32) was examined by a two-way interclass correlation coefficient for agreement (ICC 2.1A). Standard error of measurement and smallest detectable change were calculated. Construct validity was determined by calculating correlations between the FSM-ID and handheld dynamometry (HHD) (convergent validity), FSM-ID, FSM-ID and subtest strength of the Bruininks-Oseretsky test of motor proficiency - second edition (BOT-2) (convergent validity) and the FSM-ID and balance subtest of the BOT-2 (discriminant validity). Test-retest reliability ICC ranged 0.89-0.98. Correlation between the items of the FSM-ID and HHD ranged 0.39-0.79 and between FSM-ID and BOT-2 (strength items) 0.41-0.80. Correlation between items of the FSM-ID and BOT-2 (balance items) ranged 0.41-0.70. The FSM-ID showed good test-retest reliability and good convergent validity with the HHD and BOT-2 subtest strength. The correlations assessing discriminant validity were higher than expected. Poor levels of postural control and core stability in children with mild IDs may be the underlying factor of those higher correlations. © 2018 MENCAP and International Association of the Scientific Study of Intellectual and Developmental Disabilities and John Wiley & Sons Ltd.

  9. The failing measurement of attitudes: How semantic determinants of individual survey responses come to replace measures of attitude strength.

    PubMed

    Arnulf, Jan Ketil; Larsen, Kai Rune; Martinsen, Øyvind Lund; Egeland, Thore

    2018-01-12

    The traditional understanding of data from Likert scales is that the quantifications involved result from measures of attitude strength. Applying a recently proposed semantic theory of survey response, we claim that survey responses tap two different sources: a mixture of attitudes plus the semantic structure of the survey. Exploring the degree to which individual responses are influenced by semantics, we hypothesized that in many cases, information about attitude strength is actually filtered out as noise in the commonly used correlation matrix. We developed a procedure to separate the semantic influence from attitude strength in individual response patterns, and compared these results to, respectively, the observed sample correlation matrices and the semantic similarity structures arising from text analysis algorithms. This was done with four datasets, comprising a total of 7,787 subjects and 27,461,502 observed item pair responses. As we argued, attitude strength seemed to account for much information about the individual respondents. However, this information did not seem to carry over into the observed sample correlation matrices, which instead converged around the semantic structures offered by the survey items. This is potentially disturbing for the traditional understanding of what survey data represent. We argue that this approach contributes to a better understanding of the cognitive processes involved in survey responses. In turn, this could help us make better use of the data that such methods provide.

  10. Measures of static postural control moderate the association of strength and power with functional dynamic balance.

    PubMed

    Forte, Roberta; Boreham, Colin A G; De Vito, Giuseppe; Ditroilo, Massimiliano; Pesce, Caterina

    2014-12-01

    Age-related reductions in strength and power are considered to negatively impact balance control, but the existence of a direct association is still an issue of debate. This is possibly due to the fact that balance assessment is complex, reflects different underlying physiologic mechanisms and involves quantitative measurements of postural sway or timing of performance during balance tasks. The present study evaluated the moderator effect of static postural control on the association of power and strength with dynamic balance tasks. Fifty-seven healthy 65-75 year old individuals performed tests of dynamic functional balance (walking speed under different conditions) and of strength, power and static postural control. Dynamic balance performance (walking speed) was associated with lower limb strength and power, as well as postural control under conditions requiring postural adjustments (narrow surface walking r(2) = 0.31, p < 0.001). An interaction effect between strength and static postural control was found with narrow surface walking and talking while walking (change of β 0.980, p < 0.001 in strength for 1 SD improvements in static postural control for narrow walking, and [Formula: see text] -0.730, p < 0.01 in talking while walking). These results indicate that good static postural control facilitates the utilisation of lower limb strength to better perform complex, dynamic functional balance tasks. Practical implications for assessment and training are discussed.

  11. Interseason variability in isokinetic strength and poor correlation with Nordic hamstring eccentric strength in football players.

    PubMed

    van Dyk, N; Witvrouw, E; Bahr, R

    2018-04-25

    In elite sport, the use of strength testing to establish muscle function and performance is common. Traditionally, isokinetic strength tests have been used, measuring torque during concentric and eccentric muscle action. A device that measures eccentric hamstring muscle strength while performing the Nordic hamstring exercise is now also frequently used. The study aimed to investigate the variability of isokinetic muscle strength over time, for example, between seasons, and the relationship between isokinetic testing and the new Nordic hamstring exercise device. All teams (n = 18) eligible to compete in the premier football league in Qatar underwent a comprehensive strength assessment during their periodic health evaluation at Aspetar Orthopaedic and Sports Medicine Hospital in Qatar. Isokinetic strength was investigated for measurement error, and correlated to Nordic hamstring exercise strength. Of the 529 players included, 288 players had repeated tests with 1/2 seasons between test occasions. Variability (measurement error) between test occasions was substantial, as demonstrated by the measurement error (approximately 25 Nm, 15%), whether separated by 1 or 2 seasons. Considering hamstring injuries, the same pattern was observed among injured (n = 60) and uninjured (n = 228) players. A poor correlation (r = .35) was observed between peak isokinetic hamstring eccentric torque and Nordic hamstring exercise peak force. The strength imbalance between limbs calculated for both test modes was not correlated (r = .037). There is substantial intraindividual variability in all isokinetic test measures, whether separated by 1 or 2 seasons, irrespective of injury. Also, eccentric hamstring strength and limb-to-limb imbalance were poorly correlated between the isokinetic and Nordic hamstring exercise tests. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Experimental study on impact disruption of porous asteroids: Effects of oblique impact and multiple collisions on impact strength

    NASA Astrophysics Data System (ADS)

    Yasui, Minami; Takano, Shota; Matsue, Kazuma; Arakawa, Masahiko

    2015-08-01

    Most of asteroids would have pores and a plenty of pre-cracks in their interiors, and the pre-cracks could be formed by multiple impacts at various impact angles. Porosity and pre-cracks are important physical properties controlling the impact strength. Okamoto and Arakawa (2009) did impact experiments of porous gypsum spheres to obtain the impact strength of porous asteroids, but they carried out only single impact experiments on the same target at head-on. In this study, we conducted oblique impact and multiple impacts on porous gypsum and examined the effects of impact angle and pre-cracks on the impact strength.We carried out impact experiments by using the one-stage He gas gun and the two-stage H2 gas gun at Kobe University. The impact velocities were <200 m/s (low-vi) and >3 km/s (high-vi). Targets were porous gypsum spheres with the porosity of 55% and the diameters of 7 or 12 cm. The projectiles were a porous gypsum sphere with the diameter of 2.5 cm at low-vi or a polycarbonate sphere with the diameter of 4.7 cm at high-vi. The impact angle changed from 15° to 90°, and the projectile was impacted on the same target for 2-15 times. The impact phenomena were observed by a high-speed digital video camera to measure the fragment velocities.The oblique impact experiments showed that the impact strength did not depend on the impact angle θ between 45° and 90°, and obtained to be ~2000 J/kg, while it drastically changed at the θ from 15° to 30°. We reanalyzed our results by using the effective energy density defined as Qsin2θ, where Q is the energy density, and found that most of the results were consistent with the results of head-on impacts. The multiple impacts showed that the impact strength of pre-impacted targets was larger than that of intact targets in the case of low-vi. This might be caused by the compaction of the target surface. In the case of high-vi, the impact strength of pre-impacted targets was smaller than that of intact targets. This

  13. New Device for Intrinsic Hand Muscle Strength Measurement: An Alternative to Strain Gauge Handheld Dynamometer.

    PubMed

    Madhanagopal, Jagannathan; Singh, Om Prakash; Mohan, Vikram; Sathasivam, Kathiresan V; Omar, Abdul Hafidz; Abdul Kadir, Mohammed Rafiq

    2017-01-01

    An accurate measurement of intrinsic hand muscle strength (IHMS) is required by clinicians for effective clinical decision-making, diagnosis of certain diseases, and evaluation of the outcome of treatment. In practice, the clinicians use Intrins-o-meter and Rotterdam Intrinsic Hand Myometer for IHMS measurement. These are quite bulky, expensive, and possess poor interobserver reliability (37-52%) and sensitivity. The purpose of this study was to develop an alternative lightweight, accurate, cost-effective force measurement device with a simple electronic circuit and test its suitability for IHMS measurement. The device was constructed with ketjenblack/deproteinized natural rubber sensor, 1-MΩ potential divider, and Arduino Uno through the custom-written software. Then, the device was calibrated and tested for accuracy and repeatability within the force range of finger muscles (100 N). The 95% limit of agreement in accuracy from -1.95 N to 2.06 N for 10 to 100 N applied load and repeatability coefficient of ±1.91 N or 6.2% was achieved. Furthermore, the expenditure for the device construction was around US$ 53. For a practical demonstration, the device was tested among 16 participants for isometric strength measurement of the ulnar abductor and dorsal interossei. The results revealed that the performance of the device was suitable for IHMS measurement.

  14. The Influence of Resistance Training Experience on the Between-Day Reliability of Commonly Used Strength Measures in Male Youth Athletes.

    PubMed

    Weakley, Jonathon J S; Till, Kevin; Darrall-Jones, Joshua; Roe, Gregory A B; Phibbs, Padraic J; Read, Dale B; Jones, Ben L

    2017-07-01

    Weakley, JJS, Till, K, Darrall-Jones, J, Roe, GAB, Phibbs, PJ, Read, DB, and Jones, BL. The influence of resistance training experience on the between-day reliability of commonly used strength measures in male youth athletes. J Strength Cond Res 31(7): 2005-2010, 2017-The purpose of this study was to determine the between-day reliability of commonly used strength measures in male youth athletes while considering resistance training experience. Data were collected on 25 male athletes over 2 testing sessions, with 72 hours rest between, for the 3 repetition maximum (3RM) front squat, chin-up, and bench press. Subjects were initially categorized by resistance training experience (inexperienced; 6-12 months, experienced; >2 years). The assessment of the between-day reliability (coefficient of variation [CV%]) showed that the front squat (experienced: 2.90%; inexperienced: 1.90%), chin-up (experienced: 1.70%; inexperienced: 1.90%), and bench press (experienced: 4.50%; inexperienced: 2.40%) were all reliable measures of strength in both groups. Comparison between groups for the error of measurement for each exercise showed trivial differences. When both groups were combined, the CV% for the front squat, bench press, and chin-up were 2.50, 1.80, and 3.70%, respectively. This study provides scientists and practitioners with the between-day reliability reference data to determine real and practical changes for strength in male youth athletes with different resistance training experience. Furthermore, this study demonstrates that 3RM front squat, chin-up, and bench press are reliable exercises to quantify strength in male youth athletes.

  15. Target signature modeling and bistatic scattering measurement studies

    NASA Technical Reports Server (NTRS)

    Burnside, W. D.; Lee, T. H.; Rojas, R.; Marhefka, R. J.; Bensman, D.

    1989-01-01

    Four areas of study are summarized: bistatic scattering measurements studies for a compact range; target signature modeling for test and evaluation hardware in the loop situation; aircraft code modification study; and SATCOM antenna studies on aircraft.

  16. Strength and deformability of light-toned layered deposits observed by MER Opportunity: Eagle to Erebus craters, Mars

    NASA Astrophysics Data System (ADS)

    Okubo, Chris H.

    2007-10-01

    Quantifying host rock deformation is vital to understanding the geologic evolution and productivity of subsurface fluid reservoirs. In support of on-going characterization of fracture controlled fluid flow through the light-toned layered deposits on Mars, key parameters of strength and deformability are derived from Microscopic Imager and Rock Abrasion Tool data collected by the Mars Exploration Rover Opportunity in Meridiani Planum. Analysis of 21 targets of light-toned layered deposits yields a median apparent porosity of 0.25. Additional physical parameters for each target are derived from these porosity measurements. The median value of unconfined compressive strength is 11.23 MPa, Young's modulus is 1.86 GPa, and the brittle-ductile transition pressure is 8.77 MPa.

  17. Associations of Grip Strength and Change in Grip Strength With All-Cause and Cardiovascular Mortality in a European Older Population

    PubMed Central

    Prasitsiriphon, Orawan; Pothisiri, Wiraporn

    2018-01-01

    Objective: (1) To examine the associations between 3 measures of grip strength: static grip strength, change in grip strength, and the combination of grip strength and its change, with all-cause and cardiovascular mortality, and (2) to determine which measure is the most powerful predictor of all-cause and cardiovascular mortality among the European older population. Method: Data come from the first 4 waves of the Survey of Health, Ageing and Retirement in Europe (SHARE). A Cox proportional hazard model and a competing risk regression model were used to assess the associations. To determine the best predictor, Akaike information criterion was applied. Results: Grip strength and the combination of grip strength and its change were associated with all-cause and cardiovascular mortality. Change in grip strength was correlated with only all-cause mortality. Among the 3 measures, the static measure of grip strength was the best predictor of cardiovascular mortality whereas the combined measure is that of all-cause mortality. Discussion: Grip strength is a significant indicator of all-cause and cardiovascular mortality. The combination of grip strength and its change can be used to increase the accuracy for prediction of all-cause mortality among older persons.

  18. Reactive Strength Index: A Poor Indicator of Reactive Strength?

    PubMed

    Healy, Robin; Kenny, Ian; Harrison, Drew

    2017-11-28

    The primary aim was to assess the relationships between reactive strength measures and associated kinematic and kinetic performance variables achieved during drop jumps. A secondary aim was to highlight issues with the use of reactive strength measures as performance indicators. Twenty eight national and international level sprinters, consisting of fourteen men and women, participated in this cross-sectional analysis. Athletes performed drop jumps from a 0.3 m box onto a force platform with dependent variables contact time (CT), landing time (TLand), push-off time (TPush), flight time (FT), jump height (JH), reactive strength index (RSI, calculated as JH / CT), reactive strength ratio (RSR, calculated as FT / CT) and vertical leg spring stiffness (Kvert) recorded. Pearson's correlation test found very high to near perfect relationships between RSI and RSR (r = 0.91 to 0.97), with mixed relationships found between RSI, RSR and the key performance variables, (Men: r = -0.86 to -0.71 between RSI/RSR and CT, r = 0.80 to 0.92 between RSI/RSR and JH; Women: r = -0.85 to -0.56 between RSR and CT, r = 0.71 between RSI and JH). This study demonstrates that the method of assessing reactive strength (RSI versus RSR) may be influenced by the performance strategies adopted i.e. whether an athlete achieves their best reactive strength scores via low CTs, high JHs or a combination. Coaches are advised to limit the variability in performance strategies by implementing upper and / or lower CT thresholds to accurately compare performances between individuals.

  19. Strength Modeling Report

    NASA Technical Reports Server (NTRS)

    Badler, N. I.; Lee, P.; Wong, S.

    1985-01-01

    Strength modeling is a complex and multi-dimensional issue. There are numerous parameters to the problem of characterizing human strength, most notably: (1) position and orientation of body joints; (2) isometric versus dynamic strength; (3) effector force versus joint torque; (4) instantaneous versus steady force; (5) active force versus reactive force; (6) presence or absence of gravity; (7) body somatotype and composition; (8) body (segment) masses; (9) muscle group envolvement; (10) muscle size; (11) fatigue; and (12) practice (training) or familiarity. In surveying the available literature on strength measurement and modeling an attempt was made to examine as many of these parameters as possible. The conclusions reached at this point toward the feasibility of implementing computationally reasonable human strength models. The assessment of accuracy of any model against a specific individual, however, will probably not be possible on any realistic scale. Taken statistically, strength modeling may be an effective tool for general questions of task feasibility and strength requirements.

  20. Laboratory measurements of ice tensile strength dependence on density and concentration of silicate and polymer impurities at low temperatures

    NASA Astrophysics Data System (ADS)

    Litwin, K. L.; Beyeler, J. D.; Polito, P. J.; Zygielbaum, B. R.; Sklar, L. S.; Collins, G. C.

    2009-12-01

    The tensile strength of ice bedrock on Titan should strongly influence the effectiveness of the erosional processes responsible for carving the extensive fluvial drainage networks and other surface features visible in images returned by the Cassini and Huygens probes. Recent measurements of the effect of temperature on the tensile strength of low-porosity, polycrystalline ice, without impurities, suggest that ice bedrock at the Titan surface temperature of 93 K may be as much as five times stronger than ice at terrestrial surface temperatures. However, ice bedrock on Titan and other outer solar system bodies may have significant porosity, and impurities such silicates or polymers are possible in such ices. In this laboratory investigation we are exploring the dependence of tensile strength on the density and concentration of impurities, for polycrystalline ice across a wide range of temperatures. We use the Brazilian tensile splitting test to measure strength, and control temperature with dry ice and liquid nitrogen. The 50 mm diameter ice cores are made from a log-normally distributed seed crystal mixture with a median size of 1.4 mm. To control ice density and porosity we vary the packing density of the seed grains in core molds and vary the degree of saturation of the matrix with added near-freezing distilled water. We also vary ice density by blending in a similarly-sized mixture of angular fragments of two types of impurities, a fine-grained volcanic rock and a polyethylene polymer. Because both types of impurities have greater tensile strength than ice at Earth surface temperatures, we expect higher concentrations of impurities to correlate with increased strength for ice-rock and ice-polymer mixtures. However, at the ultra-cold temperatures of the outer planets, we expect significant divergence in the temperature dependence of ice tensile strength for the various mixtures and resulting densities. These measurements will help constrain the range of possible

  1. Contributions of neural excitability and voluntary activation to quadriceps muscle strength following anterior cruciate ligament reconstruction.

    PubMed

    Lepley, Adam S; Ericksen, Hayley M; Sohn, David H; Pietrosimone, Brian G

    2014-06-01

    Persistent quadriceps weakness is common following anterior cruciate ligament reconstruction (ACLr). Alterations in spinal-reflexive excitability, corticospinal excitability and voluntary activation have been hypothesized as underlying mechanisms contributing to quadriceps weakness. The aim of this study was to evaluate the predictive capabilities of spinal-reflexive excitability, corticospinal excitability and voluntary activation on quadriceps strength in healthy and ACLr participants. Quadriceps strength was measured using maximal voluntary isometric contractions (MVIC). Voluntary activation was quantified via the central activation ratio (CAR). Corticospinal and spinal-reflexive excitability were measured using active motor thresholds (AMT) and Hoffmann reflexes normalized to maximal muscle responses (H:M), respectively. ACLr individuals were also split into high and low strength subsets based on MVIC. CAR was the only significant predictor in the healthy group. In the ACLr group, CAR and H:M significantly predicted 47% of the variance in MVIC. ACLr individuals in the high strength subset demonstrated significantly higher CAR and H:M than those in the low strength subset. Increased quadriceps voluntary activation, spinal-reflexive excitability and corticospinal excitability relates to increased quadriceps strength in participants following ACLr. Rehabilitation strategies used to target neural alterations may be beneficial for the restoration of muscle strength following ACLr. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Quantitative targeting maps based on experimental investigations for a branched tube model in magnetic drug targeting

    NASA Astrophysics Data System (ADS)

    Gitter, K.; Odenbach, S.

    2011-12-01

    Magnetic drug targeting (MDT), because of its high targeting efficiency, is a promising approach for tumour treatment. Unwanted side effects are considerably reduced, since the nanoparticles are concentrated within the target region due to the influence of a magnetic field. Nevertheless, understanding the transport phenomena of nanoparticles in an artery system is still challenging. This work presents experimental results for a branched tube model. Quantitative results describe, for example, the net amount of nanoparticles that are targeted towards the chosen region due to the influence of a magnetic field. As a result of measurements, novel drug targeting maps, combining, e.g. the magnetic volume force, the position of the magnet and the net amount of targeted nanoparticles, are presented. The targeting maps are valuable for evaluation and comparison of setups and are also helpful for the design and the optimisation of a magnet system with an appropriate strength and distribution of the field gradient. The maps indicate the danger of accretion within the tube and also show the promising result of magnetic drug targeting that up to 97% of the nanoparticles were successfully targeted.

  3. Quantitative MRI and strength measurements in the assessment of muscle quality in Duchenne muscular dystrophy.

    PubMed

    Wokke, B H; van den Bergen, J C; Versluis, M J; Niks, E H; Milles, J; Webb, A G; van Zwet, E W; Aartsma-Rus, A; Verschuuren, J J; Kan, H E

    2014-05-01

    The purpose of this study was to assess leg muscle quality and give a detailed description of leg muscle involvement in a series of Duchenne muscular dystrophy patients using quantitative MRI and strength measurements. Fatty infiltration, as well as total and contractile (not fatty infiltrated) cross sectional areas of various leg muscles were determined in 16 Duchenne patients and 11 controls (aged 8-15). To determine specific muscle strength, four leg muscle groups (quadriceps femoris, hamstrings, anterior tibialis and triceps surae) were measured and related to the amount of contractile tissue. In patients, the quadriceps femoris showed decreased total and contractile cross sectional area, attributable to muscle atrophy. The total, but not the contractile, cross sectional area of the triceps surae was increased in patients, corresponding to hypertrophy. Specific strength decreased in all four muscle groups of Duchenne patients, indicating reduced muscle quality. This suggests that muscle hypertrophy and fatty infiltration are two distinct pathological processes, differing between muscle groups. Additionally, the quality of remaining muscle fibers is severely reduced in the legs of Duchenne patients. The combination of quantitative MRI and quantitative muscle testing could be a valuable outcome parameter in longitudinal studies and in the follow-up of therapeutic effects. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Strength training and physical activity in boys: a randomized trial.

    PubMed

    Meinhardt, Udo; Witassek, Fabienne; Petrò, Renato; Fritz, Chris; Eiholzer, Urs

    2013-12-01

    In developed societies levels of daily physical activity (PA) among school-age children are decreasing. This implies risk factors for cardiovascular and metabolic diseases. Specific strategies to improve levels of PA are needed. In prepubertal boys there is evidence that strength training increases spontaneous PA outside of training. A total of 102 schoolchildren (age 10-14 years) in Switzerland were randomly assigned to physical education classes or to participate twice weekly at a guided strength training program for 19 weeks. Spontaneous PA energy expenditure (PAEE; 3axial accelerometry for 7 days), leg and arm strength, and body composition (dual energy radiograph absorptiometry) were measured at baseline, after 19 weeks of training intervention, and after 3 months of washout. There were no significant differences between the groups at baseline. In the intervention group, PAEE increased by 10% from baseline to end of training in boys (P = .02), but not in girls. Leg and arm strength were increased owing to training intervention in both boys and girls. All other variables were unchanged. Baseline PAEE was significantly negatively correlated with changes of PAEE. Targeted strength training significantly increases daily spontaneous PA behavior in boys. The less active children showed the greatest increase in spontaneous PAEE. Girls showed a similar increase in strength, but not in spontaneous PAEE. This may be explained by their earlier pubertal development. Strength training may be a promising strategy in schools to counteract decreasing levels of PA.

  5. New Accurate Oscillator Strengths and Electron Excitation Collision Strengths for N I

    NASA Astrophysics Data System (ADS)

    Tayal, S. S.

    2006-03-01

    The nonorthogonal orbitals technique in a multiconfiguration Hartree-Fock approach is used to calculate oscillator strengths and transition probabilities of N I lines. The relativistic effects are allowed by means of Breit-Pauli operators. The length and velocity forms of oscillator strengths show good agreement for most transitions. The B-spline R-matrix with pseudostates approach has been used to calculate electron excitation collision strengths and rates. The nonorthogonal orbitals are used for an accurate description of both target wave functions and the R-matrix basis functions. The 24 spectroscopic bound and autoionizing states together with 15 pseudostates are included in the close-coupling expansion. The collision strengths for transitions between fine-structure levels are calculated by transforming the LS-coupled K-matrices to K-matrices in an intermediate coupling scheme. Thermally averaged collision strengths have been determined by integrating collision strengths over a Maxwellian distribution of electron energies over a temperature range suitable for the modeling of astrophysical plasmas. The oscillator strengths and thermally averaged collision strengths are presented for transitions between the fine-structure levels of the 2s22p3 4So, 2Do, 2Po, 2s2p4 4P, 2s22p23s 4P, and 2P terms and from these levels to the levels of the 2s22p23p 2So, 4Do, 4Po, 4So, 2Do, 2Po, 2s22p23s 2D, 2s22p24s 4P, 2P, 2s22p23d 2P, 4F, 2F, 4P, 4D, and 2D terms. Thermally averaged collision strengths are tabulated over a temperature range from 500 to 50,000 K.

  6. Effect of Latent Myofascial Trigger Points on Strength Measurements of the Upper Trapezius: A Case-Controlled Trial

    PubMed Central

    Anshul

    2011-01-01

    ABSTRACT Purpose: The purpose of this article was to determine whether strength is altered in the upper trapezius in the presence of latent myofascial trigger points (MTrP). Methods: This study was case controlled and used convenience sampling. The sample recruited was homogeneous with respect to age, sex, height, and body mass. Participants were assessed for the presence of latent MTrP in the upper trapezius and placed into two groups: an experimental group that had latent MTrP in the upper trapezius and a control group that did not. Eighteen women (mean age 21.4 y, SD 1.89; mean height 156.9 cm, SD 4.03; and mean body mass 51.7 kg, SD 5.84) made up the experimental group, and 19 women (mean age 20.3 y, SD 1.86; mean height 158.6 cm, SD 3.14; and mean body mass 53.2 kg, SD 5.17) made up the control group. We obtained strength measurements of the non-dominant arm using a handheld dynamometer and compared them between the two groups. Results: The difference in the strength measurements between the two groups was not statistically significant (p=0.59). Conclusions: The presence of latent MTrPs may not affect the strength of the upper trapezius. PMID:22942517

  7. Adjustment of measures of strength and power in youth male athletes differing in body mass and maturation.

    PubMed

    Meylan, Cesar Marius; Cronin, John; Hopkins, Will G; Oliver, Jonathan

    2014-02-01

    Adjustment for body mass and maturation of strength, power, and velocity measures of young athletes is important for talent development. Seventy-four youth male athletes performed a ballistic leg press test at five loads relative to body mass. The data were analyzed in maturity groups based on years from peak height velocity: -2.5 to -0.9 y (n = 29); -1.0 to 0.4 y (n = 28); and 0.5 to 2.0 y (n = 16). Allometric scaling factors representing percent difference in performance per percent difference in body mass were derived by linear regression of log-transformed variables, which also permitted adjustment of performance for body mass. Standardized differences between groups were assessed via magnitude-based inference. Strength and power measures showed a greater dependency on body mass than velocity-related variables (scaling factors of 0.56-0.85 vs. 0.42-0.14%/%), but even after adjustment for body mass most differences in strength and power were substantial (7-44%). In conclusion, increases in strength and power with maturation are due only partly to increases in body mass. Such increases, along with appropriate adjustment for body mass, need to be taken into account when comparing performance of maturing athletes.

  8. Measurement of absolute laser energy absorption by nano-structured targets

    NASA Astrophysics Data System (ADS)

    Park, Jaebum; Tommasini, R.; London, R.; Bargsten, C.; Hollinger, R.; Capeluto, M. G.; Shlyaptsev, V. N.; Rocca, J. J.

    2017-10-01

    Nano-structured targets have been reported to allow the realization of extreme plasma conditions using table top lasers, and have gained much interest as a platform to investigate the ultra-high energy density plasmas (>100 MJ/cm3) . One reason for these targets to achieve extreme conditions is increased laser energy absorption (LEA). The absolute LEA by nano-structured targets has been measured for the first time and compared to that by foil targets. The experimental results, including the effects of target parameters on the LEA, will be presented. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52097NA27344, and funded by LDRD (#15-ERD-054).

  9. Infrared small target detection based on multiscale center-surround contrast measure

    NASA Astrophysics Data System (ADS)

    Fu, Hao; Long, Yunli; Zhu, Ran; An, Wei

    2018-04-01

    Infrared(IR) small target detection plays a critical role in the Infrared Search And Track (IRST) system. Although it has been studied for years, there are some difficulties remained to the clutter environment. According to the principle of human discrimination of small targets from a natural scene that there is a signature of discontinuity between the object and its neighboring regions, we develop an efficient method for infrared small target detection called multiscale centersurround contrast measure (MCSCM). First, to determine the maximum neighboring window size, an entropy-based window selection technique is used. Then, we construct a novel multiscale center-surround contrast measure to calculate the saliency map. Compared with the original image, the MCSCM map has less background clutters and noise residual. Subsequently, a simple threshold is used to segment the target. Experimental results show our method achieves better performance.

  10. Isometric muscle strength and mobility capacity in children with cerebral palsy.

    PubMed

    Dallmeijer, Annet J; Rameckers, Eugene A; Houdijk, Han; de Groot, Sonja; Scholtes, Vanessa A; Becher, Jules G

    2017-01-01

    To determine the relationship between isometric leg muscle strength and mobility capacity in children with cerebral palsy (CP) compared to typically developing (TD) peers. Participants were 62 children with CP (6-13 years), able to walk with (n = 10) or without (n = 52) walking aids, and 47 TD children. Isometric muscle strength of five muscle groups of the leg was measured using hand-held dynamometry. Mobility capacity was assessed with the 1-min walk, the 10-m walk, sit-to-stand, lateral-step-up and timed-stair tests. Isometric strength of children with CP was reduced to 36-82% of TD. When adjusted for age and height, the percentage of variance in mobility capacity that was explained by isometric strength of the leg muscles was 21-24% (walking speed), 25% (sit-to-stand), 28% (lateral-step-up) and 35% (timed-stair) in children with CP. Hip abductors and knee flexors had the largest contribution to the explained variance, while knee extensors showed the weakest correlation. Weak or no associations were found between strength and mobility capacity in TD children. Isometric strength, especially hip abductor and knee flexor strength, is moderately related to mobility capacity in children with CP, but not in TD children. To what extent training of these muscle groups will lead to better mobility capacity needs further study. Implications for Rehabilitation Strength training in children with cerebral palsy (CP) may be targeted more specifically at hip abductors and knee flexors. The moderate associations imply that large improvements in mobility capacity may not be expected when strength increases.

  11. Grip strength measurement for frailty assessment in patients with vascular disease and associations with comorbidity, cardiac risk, and sarcopenia.

    PubMed

    Reeve, Thomas E; Ur, Rebecca; Craven, Timothy E; Kaan, James H; Goldman, Matthew P; Edwards, Matthew S; Hurie, Justin B; Velazquez-Ramirez, Gabriela; Corriere, Matthew A

    2018-05-01

    Frailty is associated with adverse events, length of stay, and nonhome discharge after vascular surgery. Frailty measures based on walking-based tests may be impractical or invalid for patients with walking impairment from symptoms or sequelae of vascular disease. We hypothesized that grip strength is associated with frailty, comorbidity, and cardiac risk among patients with vascular disease. Dominant hand grip strength was measured during ambulatory clinic visits among patients with vascular disease (abdominal aortic aneurysm [AAA], carotid stenosis, and peripheral artery disease [PAD]). Frailty prevalence was defined on the basis of the 20th percentile of community-dwelling population estimates adjusted for age, gender, and body mass index. Associations between grip strength, Charlson Comorbidity Index (CCI), Revised Cardiac Risk Index (RCRI), and sarcopenia (based on total psoas area for patients with cross-sectional abdominal imaging) were evaluated using linear and logistic regression. Grip strength was measured in 311 participants; all had sufficient data for CCI calculation, 217 (69.8%) had sufficient data for RCRI, and 88 (28.3%) had cross-sectional imaging permitting psoas measurement. Eighty-six participants (27.7%) were categorized as frail on the basis of grip strength. Frailty was associated with CCI (odds ratio, 1.86; 95% confidence interval, 1.34-2.57; P = .0002) in the multivariable model. Frail participants also had a higher average number of RCRI components vs nonfrail patients (mean ± standard deviation, 1.8 ± 0.8 for frail vs 1.5 ± 0.7 for nonfrail; P = .018); frailty was also associated with RCRI in the adjusted multivariable model (odds ratio, 1.75; 95% confidence interval, 1.16-2.64; P = .008). Total psoas area was lower among patients categorized as frail vs nonfrail on the basis of grip strength (21.0 ± 6.6 vs 25.4 ± 7.4; P = .010). Each 10 cm 2 increase in psoas area was associated with a 5.7 kg increase in grip strength

  12. Measures of Relative Dentary Strength in Rancho La Brea Smilodon fatalis over Time

    PubMed Central

    Cervantes, Kassaundra S.; Meachen, Julie A.

    2016-01-01

    The late Pleistocene megafaunal extinction of approximately 12,000 years ago, included the demise of Smilodon fatalis, a hypercarnivore from the Rancho La Brea deposits, which has been studied across time by looking at different deposits or pits to determine morphological size and shape changes and trends during this time. To better understand functional aspects of these changes, this study focused on a measure of jaw strength over time, which can give an indication of morphological changes within the jaw that cannot be seen using surface morphometrics. By radiographing dentaries, cortical bone can be seen, which provides an estimate of resistance to bending forces while biting, and can be measured and used as an indicator of jaw strength. Measurements were taken at repeatable locations on the dentary of the depth of the cortical bone, and of a standardized measure of cortical bone, which allows for the comparison between different individuals. Specimens included those of five different pits ranging from about 37 Kybp to 13 Kybp (just before the extinction of S. fatalis). No significant difference was found in the depth of jaws at any of the measurement points from any of the pits. However, significant differences were found in both the actual thickness of cortical bone, and the standardized thickness of cortical bone at the lower P4 between pit 13 (which had the lowest amount of bone) and pit 61/67 (which had the highest). These conclusions support other studies that have shown that individuals in pit 13 were under physiological and perhaps dietary stress, which may be reflected in the deposition of cortical bone, while the opposite trend is seen in the individuals in pit 61/67. Our results further support findings suggesting Smilodon did not appear to be morphologically most vulnerable right before its extinction. PMID:27598462

  13. Are anthropometric, flexibility, muscular strength, and endurance variables related to clubhead velocity in low- and high-handicap golfers?

    PubMed

    Keogh, Justin W L; Marnewick, Michel C; Maulder, Peter S; Nortje, Jacques P; Hume, Patria A; Bradshaw, Elizabeth J

    2009-09-01

    The present study assessed the anthropometric profile (International Society for the Advancement of Kinanthropometry protocol), flexibility, muscular strength, and endurance of 20 male golfers. These data were collected in order to determine: a) the relationship between these kinanthropometric measures and clubhead velocity; and b) if these measures could distinguish low-handicap (LHG) and high-handicap (HHG) golfers. Ten LHG (handicap of 0.3 +/- 0.5) and 10 HHG (handicap of 20.3 +/- 2.4) performed 10 swings for maximum velocity and accuracy with their own 5-iron golf club at a wall-mounted target. LHG hit the target significantly more (115%) and had a 12% faster clubhead velocity than HHG (p < 0.01). The LHG also had significantly (28%) greater golf swing-specific cable woodchop (GSCWC) strength (p < 0.01) and tendencies for greater (30%) bench press strength and longer (5%) upper am and total arm (4%) length and less (24%) right hip internal rotation than HHG (0.01 < p < 0.05). GSCWC strength was significantly correlated to clubhead velocity (p < 0.01), with bench press and hack squat strength as well as upper arm and total arm length also approaching significance (0.01 < p < 0.05). Golfers with high GSCWC strength and perhaps greater bench press strength and longer arms may therefore be at a competitive advantage, as these characteristics allow the production of greater clubhead velocity and resulting ball displacement. Such results have implications for golf talent identification programs and for the prescription and monitoring of golf conditioning programs. While golf conditioning programs may have many aims, specific trunk rotation exercises need to be included if increased clubhead velocity is the goal. Muscular hypertrophy development may not need to be emphasized as it could reduce golf performance by limiting range of motion and/or increasing moment of inertia.

  14. Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility.

    PubMed

    Dirnberger, Johannes; Wiesinger, Hans-Peter; Wiemer, Nicolas; Kösters, Alexander; Müller, Erich

    2016-04-01

    The present study was conducted to assess test-retest reproducibility of explosive strength measurements during single-joint isometric knee extension using the IsoMed 2000 dynamometer. Thirty-one physically active male subjects (mean age: 23.7 years) were measured on two occasions separated by 48-72 h. The intraclass correlation coefficient (ICC 2,1) and the coefficient of variation (CV) were calculated for (i) maximum torque (MVC), (ii) the peak rate of torque development (RTD peak ) as well as for (iii) the average rate of torque development (RTD) and the impulse taken at several predefined time intervals (0-30 to 0-300 ms); thereby explosive strength variables were derived in two conceptually different versions: on the one hand from the MVC-trial (version I), on the other hand from the trial showing the RTD peak (version II). High ICC-values (0.80-0.99) and acceptable CV-values (1.9-8.7%) could be found for MVC as well as for the RTD and the impulse taken at time intervals of ≥100 ms, regardless of whether version I or II was used. In contrast, measurements of the RTD peak as well as the RTD and the impulse taken during the very early contraction phase (i.e. RTD/impulse 0-30ms and RTD/impulse 0-50ms ) showed clearly weaker reproducibility results (ICC: 0.53-0.84; CV: 7.3-16.4%) and gave rise to considerable doubts as to clinical usefulness, especially when derived using version I. However, if there is a need to measure explosive strength for earlier time intervals in practice, it is, in view of stronger reproducibility results, recommended to concentrate on measures derived from version II, which is based on the RTD peak -trial.

  15. Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility

    PubMed Central

    Wiesinger, Hans-Peter; Wiemer, Nicolas; Kösters, Alexander; Müller, Erich

    2016-01-01

    Abstract The present study was conducted to assess test-retest reproducibility of explosive strength measurements during single-joint isometric knee extension using the IsoMed 2000 dynamometer. Thirty-one physically active male subjects (mean age: 23.7 years) were measured on two occasions separated by 48–72 h. The intraclass correlation coefficient (ICC 2,1) and the coefficient of variation (CV) were calculated for (i) maximum torque (MVC), (ii) the peak rate of torque development (RTDpeak) as well as for (iii) the average rate of torque development (RTD) and the impulse taken at several predefined time intervals (0–30 to 0–300 ms); thereby explosive strength variables were derived in two conceptually different versions: on the one hand from the MVC-trial (version I), on the other hand from the trial showing the RTDpeak (version II). High ICC-values (0.80–0.99) and acceptable CV-values (1.9–8.7%) could be found for MVC as well as for the RTD and the impulse taken at time intervals of ≥100 ms, regardless of whether version I or II was used. In contrast, measurements of the RTDpeak as well as the RTD and the impulse taken during the very early contraction phase (i.e. RTD/impulse0–30ms and RTD/impulse0–50ms) showed clearly weaker reproducibility results (ICC: 0.53–0.84; CV: 7.3–16.4%) and gave rise to considerable doubts as to clinical usefulness, especially when derived using version I. However, if there is a need to measure explosive strength for earlier time intervals in practice, it is, in view of stronger reproducibility results, recommended to concentrate on measures derived from version II, which is based on the RTDpeak-trial. PMID:28149337

  16. Effectiveness of Traditional Strength vs. Power Training on Muscle Strength, Power and Speed with Youth: A Systematic Review and Meta-Analysis

    PubMed Central

    Behm, David G.; Young, James D.; Whitten, Joseph H. D.; Reid, Jonathan C.; Quigley, Patrick J.; Low, Jonathan; Li, Yimeng; Lima, Camila D.; Hodgson, Daniel D.; Chaouachi, Anis; Prieske, Olaf; Granacher, Urs

    2017-01-01

    Numerous national associations and multiple reviews have documented the safety and efficacy of strength training for children and adolescents. The literature highlights the significant training-induced increases in strength associated with youth strength training. However, the effectiveness of youth strength training programs to improve power measures is not as clear. This discrepancy may be related to training and testing specificity. Most prior youth strength training programs emphasized lower intensity resistance with relatively slow movements. Since power activities typically involve higher intensity, explosive-like contractions with higher angular velocities (e.g., plyometrics), there is a conflict between the training medium and testing measures. This meta-analysis compared strength (e.g., training with resistance or body mass) and power training programs (e.g., plyometric training) on proxies of muscle strength, power, and speed. A systematic literature search using a Boolean Search Strategy was conducted in the electronic databases PubMed, SPORT Discus, Web of Science, and Google Scholar and revealed 652 hits. After perusal of title, abstract, and full text, 107 studies were eligible for inclusion in this systematic review and meta-analysis. The meta-analysis showed small to moderate magnitude changes for training specificity with jump measures. In other words, power training was more effective than strength training for improving youth jump height. For sprint measures, strength training was more effective than power training with youth. Furthermore, strength training exhibited consistently large magnitude changes to lower body strength measures, which contrasted with the generally trivial, small and moderate magnitude training improvements of power training upon lower body strength, sprint and jump measures, respectively. Maturity related inadequacies in eccentric strength and balance might influence the lack of training specificity with the unilateral

  17. Effectiveness of Traditional Strength vs. Power Training on Muscle Strength, Power and Speed with Youth: A Systematic Review and Meta-Analysis.

    PubMed

    Behm, David G; Young, James D; Whitten, Joseph H D; Reid, Jonathan C; Quigley, Patrick J; Low, Jonathan; Li, Yimeng; Lima, Camila D; Hodgson, Daniel D; Chaouachi, Anis; Prieske, Olaf; Granacher, Urs

    2017-01-01

    Numerous national associations and multiple reviews have documented the safety and efficacy of strength training for children and adolescents. The literature highlights the significant training-induced increases in strength associated with youth strength training. However, the effectiveness of youth strength training programs to improve power measures is not as clear. This discrepancy may be related to training and testing specificity. Most prior youth strength training programs emphasized lower intensity resistance with relatively slow movements. Since power activities typically involve higher intensity, explosive-like contractions with higher angular velocities (e.g., plyometrics), there is a conflict between the training medium and testing measures. This meta-analysis compared strength (e.g., training with resistance or body mass) and power training programs (e.g., plyometric training) on proxies of muscle strength, power, and speed. A systematic literature search using a Boolean Search Strategy was conducted in the electronic databases PubMed, SPORT Discus, Web of Science, and Google Scholar and revealed 652 hits. After perusal of title, abstract, and full text, 107 studies were eligible for inclusion in this systematic review and meta-analysis. The meta-analysis showed small to moderate magnitude changes for training specificity with jump measures. In other words, power training was more effective than strength training for improving youth jump height. For sprint measures, strength training was more effective than power training with youth. Furthermore, strength training exhibited consistently large magnitude changes to lower body strength measures, which contrasted with the generally trivial, small and moderate magnitude training improvements of power training upon lower body strength, sprint and jump measures, respectively. Maturity related inadequacies in eccentric strength and balance might influence the lack of training specificity with the unilateral

  18. Hip strength assessment using handheld dynamometry is subject to intertester bias when testers are of different sex and strength.

    PubMed

    Thorborg, K; Bandholm, T; Schick, M; Jensen, J; Hölmich, P

    2013-08-01

    Handheld dynamometry (HHD) is a promising tool for obtaining reliable hip strength measurements in the clinical setting, but intertester reliability has been questioned, especially in situations where testers exhibit differences in upper-extremity muscle strength (male vs female). The purpose of this study was to examine the intertester reliability concerning strength assessments of hip abduction, adduction, external and internal rotation, flexion and extension using HHD, and to test whether systematic differences in test values exist between testers of different upper-extremity strength. Fifty healthy individuals (29 women), aged 25 ± 5 years were included. Two physiotherapist students (one female, one male) of different upper-extremity strength performed the measurements. The tester order and strength test order were randomized. Intraclass correlation coefficients were used to quantify reliability, and ranged from 0.82 to 0.91 for the six strength test. The female tester systematically measured lower strength values for all isometric strength tests (P < 0.05). In hip strength assessments using HHD, systematic bias exists between testers of different sex, which is likely explained by differences in upper-extremity strength. Hence, to improve intertester reliability, the dynamometer likely needs external fixation, as this will eliminate the influence of differences in upper-extremity strength between testers. © 2011 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Osteoporosis: Are we measuring what we intend to measure? In search of the ideal bone strength study

    NASA Astrophysics Data System (ADS)

    de Riese, Cornelia

    2006-02-01

    In 1991 the World Health Organization (WHO) defined osteoporosis as a "loss of bone mass and micro architectural deterioration of the skeleton leading to increased risk of fracture." 1,2 Since microarchitecture can not be measured directly, a panel of the WHO recommended that the diagnosis be made according to a quantifiable surrogate marker, calcium mineral, in bone. Subsequently in 1994, the definition focused on the actual bone "density," giving densitometric technology a central place in establishing the diagnosis of osteoporosis. 3,4 But soon it became obvious that there was only limited correlation between bone mineral density (BMD) and actual occurrence of fractures and that decreases in bone mass account for only about 50% of the deterioration of bone strength with aging. In other words only about 60% of bone strength is related to BMD. 5 Recent developments in bone research have shown that bone mineral density in itself is not sufficient to accurately predict fracture risk. Bone is composed of inorganic calcium apatite crystals that mineralize an organic type I collagen matrix. The degree of mineralization, the properties of the collagen matrix, crystal size, trabecular orientation, special distribution of the different components and many more factors are all impacting bone strength. 6-14 Human cadaver studies have confirmed the correlation between bone density and bone. 26 strength. 5,15-20 Changes in cancellous bone morphology appear to lead to a disproportionate decrease in bone strength. 21-26 When postmenopausal women are stratified by age, obvious differences between BMD and actual fracture risk are observed. 24 Felsenberg eloquently summarizes what he calls the "Bone Quality Framework." In great detail he talks about the geometry and micro- architecture of bone and how the different components are related to functional stability. 27 Are our current testing modalities appropriately addressing these structural factors? Are we keeping in mind that in

  20. Impaired muscle strength may contribute to fatigue in patients with aneurysmal subarachnoid hemorrhage.

    PubMed

    Harmsen, Wouter J; Ribbers, Gerard M; Zegers, Bart; Sneekes, Emiel M; Praet, Stephan F E; Heijenbrok-Kal, Majanka H; Khajeh, Ladbon; van Kooten, Fop; Neggers, Sebastiaan J C M M; van den Berg-Emons, Rita J

    2017-03-01

    Patients with aneurysmal subarachnoid hemorrhage (a-SAH) show long-term fatigue and face difficulties in resuming daily physical activities. Impaired muscle strength, especially of the lower extremity, impacts the performance of daily activities and may trigger the onset of fatigue complaints. The present study evaluated knee muscle strength and fatigue in patients with a-SAH. This study included 33 patients, 6 months after a-SAH, and 33 sex-matched and age-matched healthy controls. Isokinetic muscle strength of the knee extensors and flexors was measured at 60 and 180°/s. Maximal voluntary muscle strength was defined as peak torque and measured in Newton-meter. Fatigue was examined using the Fatigue Severity Scale. In patients with a-SAH, the maximal knee extension was 22% (60°/s) and 25% (180°/s) lower and maximal knee flexion was 33% (60°/s) and 36% (180°/s) lower compared with that of matched controls (P≤0.001). The Fatigue Severity Scale score was related to maximal knee extension (60°/s: r=-0.426, P=0.015; 180°/s: r=-0.376, P=0.034) and flexion (60°/s: r=-0.482, P=0.005; 180°/s: r=-0.344, P=0.083). The knee muscle strength was 28-47% lower in fatigued (n=13) and 11-32% lower in nonfatigued (n=20) patients; deficits were larger in fatigued patients (P<0.05), particularly when the muscle strength (peak torque) was measured at 60°/s. The present results indicate that patients with a-SAH have considerably impaired knee muscle strength, which is related to more severe fatigue. The present findings are exploratory, but showed that knee muscle strength may play a role in the severity of fatigue complaints, or vice versa. Interventions targeting fatigue after a-SAH seem necessary and may consider strengthening exercise training in order to treat a debilitating condition.

  1. Reproducibility of isometric shoulder protraction and retraction strength measurements in normal subjects and individuals with winged scapula.

    PubMed

    Oh, Jae-Seop; Kang, Min-Hyeok; Dvir, Zeevi

    2016-11-01

    The strength of the shoulder protractors and retractors may be compromised in individuals with winged scapula (IwWS). However, no standard approach to measuring the strength of these muscles has been described. The aim of this study was to study the intra-rater and inter-rater reproducibility of a fixed-base isometric dynamometer and to describe cutoff scores for clinically meaningful change for protraction and retraction isometric strength. Twice during a week, 20 normal subjects and 20 IwWS were tested by 2 independent raters. IwWS were significantly weaker (P < .001) than control subjects in their protraction and retraction isometric strength. Excellent intra-rater and inter-rater correlations were obtained in most combinations, leading to low cutoff scores for meaningful change expressed in terms of the smallest real difference. When it is properly used, the technique described in this paper is recommended as an effective clinical tool for the quantitative assessment of protraction and retraction isometric strength, both for status determination and for monitoring of change in IwWS during and after rehabilitation. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  2. Effective collision strengths for the electron impact excitation of Mg

    NASA Astrophysics Data System (ADS)

    Hudson, C. E.; Ramsbottom, C. A.; Norrington, P. H.; Scott, M. P.

    2008-05-01

    Electron impact excitation collision strengths for fine structure transitions of Mg,have been determined by a Breit-Pauli R-matrix calculation. The target states are represented by configuration interaction wavefunctions and consist of the 19 lowest LS states, having configurations 2s^22p^4, 2s2p^5, 2p^6, 2s^22p^33s and 2s^22p^33p. These target states give rise to 37 fine structure levels and 666 possible transitions. The effective collision strengths are calculated by averaging the electron collision strengths over a Maxwellian distribution of electron velocities. Effective collision strengths for transitions between the fine structure levels are given for electron temperatures in the range 10Te(K) = 3.0 - 7.0. Results are compared with the previous R-matrix calculation of Butler & Zeippen (AASS, 1994) and the recent Distorted Wave evaluations of Bhatia, Landi & Eissner (ADNDT, 2006).

  3. A real-time optical tracking and measurement processing system for flying targets.

    PubMed

    Guo, Pengyu; Ding, Shaowen; Zhang, Hongliang; Zhang, Xiaohu

    2014-01-01

    Optical tracking and measurement for flying targets is unlike the close range photography under a controllable observation environment, which brings extreme conditions like diverse target changes as a result of high maneuver ability and long cruising range. This paper first designed and realized a distributed image interpretation and measurement processing system to achieve resource centralized management, multisite simultaneous interpretation and adaptive estimation algorithm selection; then proposed a real-time interpretation method which contains automatic foreground detection, online target tracking, multiple features location, and human guidance. An experiment is carried out at performance and efficiency evaluation of the method by semisynthetic video. The system can be used in the field of aerospace tests like target analysis including dynamic parameter, transient states, and optical physics characteristics, with security control.

  4. Handgrip Strength and Ideal Cardiovascular Health among Colombian Children and Adolescents.

    PubMed

    Ramírez-Vélez, Robinson; Tordecilla-Sanders, Alejandra; Correa-Bautista, Jorge Enrique; Peterson, Mark D; Garcia-Hermoso, Antonio

    2016-12-01

    To evaluate the association between handgrip strength and ideal cardiovascular health (CVH) in Colombian children and adolescents. During the 2014-2015 school years, we examined a cross-sectional component of the FUPRECOL (Association for Muscular Strength with Early Manifestation of Cardiovascular Disease Risk Factors among Colombian Children and Adolescents) study. Participants included 1199 (n = 627 boys) youths from Bogota (Colombia). Handgrip strength was measured with a standard adjustable hand held dynamometer and expressed relative to body mass (handgrip/body mass) and as absolute values in kilograms. Ideal CVH, as defined by the American Heart Association, was determined as meeting ideal levels of the following components: 4 behaviors (smoking status, body mass index, cardiorespiratory fitness, and diet) and 3 factors (total cholesterol, blood pressure, and glucose). Higher levels of handgrip strength (both absolute and relative values) were associated with a higher frequency of ideal CVH metrics in both sexes (P for trend ≤ .001). Also, higher levels of handgrip strength were associated with a greater number of ideal health behaviors (P for trend < .001 in both boys and girls), and with a higher number of ideal health factors in boys (P for trend < .001). Finally, levels of handgrip strength were similar between ideal versus nonideal glucose or total cholesterol groups in girls. Handgrip strength was strongly associated with ideal CVH in Colombian children and adolescents, and thus supports the relevance of early targeted interventions to promote strength adaptation and preservation as part of primordial prevention. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Sinusoidal Siemens star spatial frequency response measurement errors due to misidentified target centers

    DOE PAGES

    Birch, Gabriel Carisle; Griffin, John Clark

    2015-07-23

    Numerous methods are available to measure the spatial frequency response (SFR) of an optical system. A recent change to the ISO 12233 photography resolution standard includes a sinusoidal Siemens star test target. We take the sinusoidal Siemens star proposed by the ISO 12233 standard, measure system SFR, and perform an analysis of errors induced by incorrectly identifying the center of a test target. We show a closed-form solution for the radial profile intensity measurement given an incorrectly determined center and describe how this error reduces the measured SFR of the system. As a result, using the closed-form solution, we proposemore » a two-step process by which test target centers are corrected and the measured SFR is restored to the nominal, correctly centered values.« less

  6. The effect of Nordic hamstring strength training on muscle architecture, stiffness, and strength.

    PubMed

    Seymore, Kayla D; Domire, Zachary J; DeVita, Paul; Rider, Patrick M; Kulas, Anthony S

    2017-05-01

    Hamstring strain injury is a frequent and serious injury in competitive and recreational sports. While Nordic hamstring (NH) eccentric strength training is an effective hamstring injury-prevention method, the protective mechanism of this exercise is not understood. Strength training increases muscle strength, but also alters muscle architecture and stiffness; all three factors may be associated with reducing muscle injuries. The purpose of this study was to examine the effects of NH eccentric strength training on hamstring muscle architecture, stiffness, and strength. Twenty healthy participants were randomly assigned to an eccentric training group or control group. Control participants performed static stretching, while experimental participants performed static stretching and NH training for 6 weeks. Pre- and post-intervention measurements included: hamstring muscle architecture and stiffness using ultrasound imaging and elastography, and maximal hamstring strength measured on a dynamometer. The experimental group, but not the control group, increased volume (131.5 vs. 145.2 cm 3 , p < 0.001) and physiological cross-sectional area (16.1 vs. 18.1 cm 2 , p = 0.032). There were no significant changes to muscle fascicle length, stiffness, or eccentric hamstring strength. The NH intervention was an effective training method for muscle hypertrophy, but, contrary to common literature findings for other modes of eccentric training, did not increase fascicle length. The data suggest that the mechanism behind NH eccentric strength training mitigating hamstring injury risk could be increasing volume rather than increasing muscle length. Future research is, therefore, warranted to determine if muscle hypertrophy induced by NH training lowers future hamstring strain injury risk.

  7. 47 CFR 24.236 - Field strength limits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 2 2011-10-01 2011-10-01 false Field strength limits. 24.236 Section 24.236... SERVICES Broadband PCS § 24.236 Field strength limits. The predicted or measured median field strength at... to a higher field strength. ...

  8. 47 CFR 24.236 - Field strength limits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Field strength limits. 24.236 Section 24.236... SERVICES Broadband PCS § 24.236 Field strength limits. The predicted or measured median field strength at... to a higher field strength. ...

  9. Potential Measurements of Coronal Magnetic Field Strengths Using Line Ratios in EUV and X-ray Spectra

    NASA Astrophysics Data System (ADS)

    Beiersdorfer, Peter; Scofield, J. H.; Lepson, J. K.; Osten, R.; Smith, R. K.

    2006-09-01

    We will discuss a class of lines from highly charged ions that are sensitive to the strength of the ambient magnetic field. Calculations show that the magnitude of field strengths that can be measured ranges from a few hundred gauss to several tens of kilogauss depending on the particular ion emitting the line. These calculations have been verified in the laboratory by studying the spectra of S VII, Ar IX, and Fe XVII. As an example of the diagnostic utility, the possibility of using these lines to determine the coronal magnetic field strength of Prox Cen will be presented. This work was supported by NASA Astronomy and Physics Research and Analysis program work order NNH04AA751, and was performed under the auspices of the Department of Energy by the University of California Lawrence Livermore National Laboratory under Contract No. W-7405-ENG-48.

  10. Validity and reliability of a low-cost digital dynamometer for measuring isometric strength of lower limb.

    PubMed

    Romero-Franco, Natalia; Jiménez-Reyes, Pedro; Montaño-Munuera, Juan A

    2017-11-01

    Lower limb isometric strength is a key parameter to monitor the training process or recognise muscle weakness and injury risk. However, valid and reliable methods to evaluate it often require high-cost tools. The aim of this study was to analyse the concurrent validity and reliability of a low-cost digital dynamometer for measuring isometric strength in lower limb. Eleven physically active and healthy participants performed maximal isometric strength for: flexion and extension of ankle, flexion and extension of knee, flexion, extension, adduction, abduction, internal and external rotation of hip. Data obtained by the digital dynamometer were compared with the isokinetic dynamometer to examine its concurrent validity. Data obtained by the digital dynamometer from 2 different evaluators and 2 different sessions were compared to examine its inter-rater and intra-rater reliability. Intra-class correlation (ICC) for validity was excellent in every movement (ICC > 0.9). Intra and inter-tester reliability was excellent for all the movements assessed (ICC > 0.75). The low-cost digital dynamometer demonstrated strong concurrent validity and excellent intra and inter-tester reliability for assessing isometric strength in the main lower limb movements.

  11. A Real-Time Optical Tracking and Measurement Processing System for Flying Targets

    PubMed Central

    Guo, Pengyu; Ding, Shaowen; Zhang, Hongliang; Zhang, Xiaohu

    2014-01-01

    Optical tracking and measurement for flying targets is unlike the close range photography under a controllable observation environment, which brings extreme conditions like diverse target changes as a result of high maneuver ability and long cruising range. This paper first designed and realized a distributed image interpretation and measurement processing system to achieve resource centralized management, multisite simultaneous interpretation and adaptive estimation algorithm selection; then proposed a real-time interpretation method which contains automatic foreground detection, online target tracking, multiple features location, and human guidance. An experiment is carried out at performance and efficiency evaluation of the method by semisynthetic video. The system can be used in the field of aerospace tests like target analysis including dynamic parameter, transient states, and optical physics characteristics, with security control. PMID:24987748

  12. Mathematical model of the two-point bending test for strength measurement of optical fibers

    NASA Astrophysics Data System (ADS)

    Srubshchik, Leonid S.

    1999-12-01

    The mathematical and numerical analysis of two nonlinear problems of solid mechanics related to the breaking strength of coated optical glass fibers are presented. Both of these problems are concerned with the two-point bending technique which measures the strength of optical fibers by straining them in a bending mode between two parallel plates. The plates are squeezed together until the fiber fractures. The process gives a measurement of fiber strength. The present theory of this test is based on the elastica theory of an unshearable and inextensible rod. However, within the limits of the elastics theory the tensile and shear stresses cannot be determined. In this paper we study the behavior of optical glass fiber on the base of a geometrically exact nonlinear Cosserat theory in which a rod can suffer flexure, extension, and shear. We adopt the specific nonlinear stress-strain relations in silica and titania-doped silica glass fibers and show that it does not yield essential changes in the results as compared with the results for the linear stress-strain relations. We obtain the governing equations of the motion of the fiber in the two-point bending test taking into account the friction between the test fiber and the rigid plates. We develop the computational methods to solve the initial and equilibrium free-boundary nonlinear planar problems. We derive formulas for tensile and shear stresses which allow us to calculate tension in the fiber. The numerical results show that frictional forces play an important role. The interaction of optical fiber and rigid plates is treated by means of the classical contact theory.

  13. Hip Strength in Patients with Quadriceps Strength Deficits after ACL Reconstruction.

    PubMed

    Bell, David R; Trigsted, Stephanie M; Post, Eric G; Walden, Courtney E

    2016-10-01

    Quadriceps strength deficits persist for years after anterior cruciate ligament (ACL) reconstruction, and patients with these deficits often shift torque demands away from the knee extensors to the hip during functional tasks. However, it is not clear how quadriceps strength deficits may affect hip strength. Therefore, the purpose of this study was to investigate differences in lower extremity strength in individuals with ACL reconstruction with differing levels of quadriceps strength asymmetry. Isometric strength was recorded bilaterally in 135 participants (73 control and 62 with unilateral ACL reconstruction, time from surgery = 30.9 ± 17.6 months) from the knee extensors and flexors, hip extensors and abductors, and hip internal and external rotator muscle groups. Symmetry indices (limb symmetry index (LSI)) were created based on quadriceps strength, and subjects with ACL reconstruction were subdivided (high quadriceps (LSI ≥ 90%), n = 37; low quadriceps (LSI < 85%), n = 18). Individual group (control vs high quadriceps vs low quadriceps) by limb (reconstructed/nondominant vs healthy/dominant) repeated-measures ANOVA was used to compare strength (%BW) for each of the six joint motions of interest (knee extensors/flexors, hip abductors/extensors/external, and internal rotators) while controlling for time from surgery. An interaction was observed for quadriceps strength (P < 0.001), and the reconstructed limb in the low quadriceps group was weaker than all other limbs. A main effect for group was observed with the low quadriceps group having greater hip extension (P = 0.007) strength in both limbs compared with the other groups. Knee flexion strength was weaker in the reconstructed limb of the high quadriceps group (P = 0.047) compared with all other groups and limbs. Individuals with ACL reconstruction and involved limb quadriceps weakness have greater hip extension strength in both limbs compared with patients with bilateral strength symmetry and controls.

  14. The use of the isometric squat as a measure of strength and explosiveness.

    PubMed

    Bazyler, Caleb D; Beckham, George K; Sato, Kimitake

    2015-05-01

    The isometric squat has been used to detect changes in kinetic variables as a result of training; however, controversy exists in its application to dynamic multijoint tasks. Thus, the purpose of this study was to further examine the relationship between isometric squat kinetic variables and isoinertial strength measures. Subjects (17 men, 1-repetition maximum [1RM]: 148.2 ± 23.4 kg) performed squats 2 d · wk(-1) for 12 weeks and were tested on 1RM squat, 1RM partial squat, and isometric squat at 90° and 120° of knee flexion. Test-retest reliability was very good for all isometric measures (intraclass correlation coefficients > 0.90); however, rate of force development 250 milliseconds at 90° and 120° seemed to have a higher systematic error (relative technical error of measurement = 8.12%, 9.44%). Pearson product-moment correlations indicated strong relationships between isometric peak force at 90° (IPF 90°) and 1RM squat (r = 0.86), and IPF 120° and 1RM partial squat (r = 0.79). Impulse 250 milliseconds (IMP) at 90° and 120° exhibited moderate to strong correlations with 1RM squat (r = 0.70, 0.58) and partial squat (r = 0.73, 0.62), respectively. Rate of force development at 90° and 120° exhibited weak to moderate correlations with 1RM squat (r = 0.55, 0.43) and partial squat (r = 0.32, 0.42), respectively. These findings demonstrate a degree of joint angle specificity to dynamic tasks for rapid and peak isometric force production. In conclusion, an isometric squat performed at 90° and 120° is a reliable testing measure that can provide a strong indication of changes in strength and explosiveness during training.

  15. Time-reversal optical tomography: detecting and locating extended targets in a turbid medium

    NASA Astrophysics Data System (ADS)

    Wu, Binlin; Cai, W.; Xu, M.; Gayen, S. K.

    2012-03-01

    Time Reversal Optical Tomography (TROT) is developed to locate extended target(s) in a highly scattering turbid medium, and estimate their optical strength and size. The approach uses Diffusion Approximation of Radiative Transfer Equation for light propagation along with Time Reversal (TR) Multiple Signal Classification (MUSIC) scheme for signal and noise subspaces for assessment of target location. A MUSIC pseudo spectrum is calculated using the eigenvectors of the TR matrix T, whose poles provide target locations. Based on the pseudo spectrum contours, retrieval of target size is modeled as an optimization problem, using a "local contour" method. The eigenvalues of T are related to optical strengths of targets. The efficacy of TROT to obtain location, size, and optical strength of one absorptive target, one scattering target, and two absorptive targets, all for different noise levels was tested using simulated data. Target locations were always accurately determined. Error in optical strength estimates was small even at 20% noise level. Target size and shape were more sensitive to noise. Results from simulated data demonstrate high potential for application of TROT in practical biomedical imaging applications.

  16. Cumulative Damage in Strength-Dominated Collisions of Rocky Asteroids: Rubble Piles and Brick Piles

    NASA Technical Reports Server (NTRS)

    Housen, Kevin

    2009-01-01

    Laboratory impact experiments were performed to investigate the conditions that produce large-scale damage in rock targets. Aluminum cylinders (6.3 mm diameter) impacted basalt cylinders (69 mm diameter) at speeds ranging from 0.7 to 2.0 km/s. Diagnostics included measurements of the largest fragment mass, velocities of the largest remnant and large fragments ejected from the periphery of the target, and X-ray computed tomography imaging to inspect some of the impacted targets for internal damage. Significant damage to the target occurred when the kinetic energy per unit target mass exceeded roughly 1/4 of the energy required for catastrophic shattering (where the target is reduced to one-half its original mass). Scaling laws based on a rate-dependent strength were developed that provide a basis for extrapolating the results to larger strength-dominated collisions. The threshold specific energy for widespread damage was found to scale with event size in the same manner as that for catastrophic shattering. Therefore, the factor of four difference between the two thresholds observed in the lab also applies to larger collisions. The scaling laws showed that for a sequence of collisions that are similar in that they produce the same ratio of largest fragment mass to original target mass, the fragment velocities decrease with increasing event size. As a result, rocky asteroids a couple hundred meters in diameter should retain their large ejecta fragments in a jumbled rubble-pile state. For somewhat larger bodies, the ejection velocities are sufficiently low that large fragments are essentially retained in place, possibly forming ordered "brick-pile" structures.

  17. Glenohumeral and Hip Range-of-Motion and Strength Measures in Youth Baseball Athletes

    PubMed Central

    Harding, Josie L.; Bliven, Kellie C. Huxel

    2016-01-01

    Context:  The repetitive demands of throwing affect glenohumeral (GH) range of motion (ROM) and strength. Less is known about hip alterations in skeletally immature athletes. Objective:  To compare GH and hip ROM and strength between age, position, and side of youth baseball athletes. Design:  Cross-sectional study. Setting:  Multicenter testing. Patients or Other Participants:  Seventy-two healthy baseball athletes. Participants' self-reported characteristics were age group (7−11 years [n = 28] or 12−18 years [n = 44]), position (pitcher [n = 22], position player [n = 47], unreported [n = 3]), and side (throwing or nonthrowing arm, lead or stance leg). Main Outcome Measure(s):  Bilateral GH and hip internal- and external-rotation ROM were measured passively and summed for total arc of motion (TAM). Glenohumeral and hip rotation and gluteus medius strength were measured. Analyses included linear mixed models. Results:  Glenohumeral internal rotation was less in throwing than in nonthrowing arms (P < .05) except in younger pitchers (P = .86). Compared with older athletes, younger athletes had more GH external rotation (103.3° ± 7.7° versus 97.5° ± 9.4°; P = .002), TAM (156.4° ± 8.7° versus 147.9° ± 10.9°; P = .04), and external rotation in throwing compared with nonthrowing arms (101.9° ± 1.2° versus 97.9° ± 1.1°; P < .001). Glenohumeral TAM was less in throwing than in nonthrowing arms (150.5° ± 2.1° versus 154.9° ± 1.3°; P = .01). Younger athletes had more hip internal rotation (38.9° ± 6.8° versus 31.2° ± 7.5°; P < .001) and TAM (68.4° ± 10.0° versus 60.7° ± 9.8°; P = .001) than older athletes. Lead-leg hip internal-rotation ROM was greater than in the stance leg (34.8° ± 8.9° versus 32.8° ± 7.7°; P = .01). Overall, older players were stronger than younger players (P < .05), and the throwing arm was stronger in internal rotation than the nonthrowing arm (10.12 ± 3.72 lb [4.59 ± 1.69 kg] versus 9.43

  18. Target micro-displacement measurement by a "comb" structure of intensity distribution in laser plasma propulsion

    NASA Astrophysics Data System (ADS)

    Zheng, Z. Y.; Zhang, S. Q.; Gao, L.; Gao, H.

    2015-05-01

    A "comb" structure of beam intensity distribution is designed and achieved to measure a target displacement of micrometer level in laser plasma propulsion. Base on the "comb" structure, the target displacement generated by nanosecond laser ablation solid target is measured and discussed. It is found that the "comb" structure is more suitable for a thin film target with a velocity lower than tens of millimeters per second. Combing with a light-electric monitor, the `comb' structure can be used to measure a large range velocity.

  19. The effects of a 12-week strength-training program on strength and functionality in women with fibromyalgia.

    PubMed

    Kingsley, J Derek; Panton, Lynn B; Toole, Tonya; Sirithienthad, Prawee; Mathis, Reed; McMillan, Victor

    2005-09-01

    To determine whether women with fibromyalgia benefit from strength training. Randomized controlled trial. Testing was completed at the university and training was completed at a local community wellness facility. Twenty-nine women (age range, 18-54 y) with fibromyalgia participated. Subjects were randomly assigned to a control (n=14; wait-listed for exercise) or strength (n=15) group. After the first 4 weeks, 7 (47%) women dropped from the strength group. Subjects underwent 12 weeks of training on 11 exercises, 2 times a week, performing 1 set of 8 to 12 repetitions at 40% to 60% of their maximal lifts and were progressed to 60% to 80%. Subjects were measured for strength, functionality, tender point sensitivity, and fibromyalgia impact. The strength group significantly (P< or =.05) improved upper- (strength, 39+/-11 to 42+/-12 kg; control, 38+/-13 to 38+/-12 kg) and lower- (strength, 68+/-28 to 82+/-25 kg; control, 61+/-25 to 61+/-26 kg) body strength. Upper-body functionality measured by the Continuous-Scale Physical Functional Performance test improved significantly (strength, 44+/-11 to 50+/-16U; control, 51+/-11 to 49+/-13U) after training. Tender point sensitivity and fibromyalgia impact did not change. Strength training improved strength and some functionality in women with fibromyalgia. Interventions with resistance have important implications on independence and quality of life issues for women with fibromyalgia.

  20. Development and Validation of a Measure of Interpersonal Strengths: The Inventory of Interpersonal Strengths

    ERIC Educational Resources Information Center

    Hatcher, Robert L.; Rogers, Daniel T.

    2009-01-01

    An Inventory of Interpersonal Strengths (IIS) was developed and validated in a series of large college student samples. Based on interpersonal theory and associated methods, the IIS was designed to assess positive characteristics representing the full range of interpersonal domains, including those generally thought to have negative qualities…

  1. Two-photon-absorption line strengths for nitric oxide: Comparison of theory and sub-Doppler, laser-induced fluorescence measurements

    NASA Astrophysics Data System (ADS)

    Kulatilaka, Waruna D.; Lucht, Robert P.

    2017-03-01

    We discuss the results of high-resolution, sub-Doppler two-photon-absorption laser-induced fluorescence (TPALIF) spectroscopy of nitric oxide at low pressure and room temperature. The measurements were performed using the single-longitudinal mode output of a diode-laser-seeded optical parametric generator (OPG) system with a measured frequency bandwidth of 220 MHz. The measurements were performed using a counter-propagating pump beam geometry, resulting in sub-Doppler TPALIF spectra of NO for various rotational transitions in the (0,0) vibrational band of the A2Σ+ - X2Π electronic transition. The experimental results are compared with the results of a perturbative treatment of the rotational line strengths for the 20 different rotational branches of the X2Π(v″ = 0) → A2Σ+(v' = 0) two-photon absorption band. In the derivation of the expressions for the two-photon transition absorption strength, the closure relation is used for rotational states in the intermediate levels of the two-photon transition in analogy with the Placzek treatment of Raman transitions. The theoretical treatment of the effect of angular momentum coupling on the two-photon rotational line strengths features the use of irreducible spherical tensors and 3j symbols. The final results are expressed in terms of the Hund's case (a) coupling coefficients aJ and bJ for the X2Π(v″ = 0) rotational level wavefunctions, which are intermediate between Hund's case (a) and case (b). Considerable physical insight is provided by this final form of the equations for the rotational line strengths. Corrections to the two-photon absorption rotational line strength for higher order effects such as centrifugal stretching can be included in a straightforward fashion in the analysis by incorporating higher order terms in these coupling coefficients aJ and bJ, although these corrections are essentially negligible for J < 50. The theoretical calculations of relative line intensities are in good agreement both

  2. Correlation Filter Learning Toward Peak Strength for Visual Tracking.

    PubMed

    Sui, Yao; Wang, Guanghui; Zhang, Li

    2018-04-01

    This paper presents a novel visual tracking approach to correlation filter learning toward peak strength of correlation response. Previous methods leverage all features of the target and the immediate background to learn a correlation filter. Some features, however, may be distractive to tracking, like those from occlusion and local deformation, resulting in unstable tracking performance. This paper aims at solving this issue and proposes a novel algorithm to learn the correlation filter. The proposed approach, by imposing an elastic net constraint on the filter, can adaptively eliminate those distractive features in the correlation filtering. A new peak strength metric is proposed to measure the discriminative capability of the learned correlation filter. It is demonstrated that the proposed approach effectively strengthens the peak of the correlation response, leading to more discriminative performance than previous methods. Extensive experiments on a challenging visual tracking benchmark demonstrate that the proposed tracker outperforms most state-of-the-art methods.

  3. Evaluation of a novel ultra small target technology supporting on-product overlay measurements

    NASA Astrophysics Data System (ADS)

    Smilde, Henk-Jan H.; den Boef, Arie; Kubis, Michael; Jak, Martin; van Schijndel, Mark; Fuchs, Andreas; van der Schaar, Maurits; Meyer, Steffen; Morgan, Stephen; Wu, Jon; Tsai, Vincent; Wang, Cathy; Bhattacharyya, Kaustuve; Chen, Kai-Hsiung; Huang, Guo-Tsai; Ke, Chih-Ming; Huang, Jacky

    2012-03-01

    Reducing the size of metrology targets is essential for in-die overlay metrology in advanced semiconductor manufacturing. In this paper, μ-diffraction-based overlay (μDBO) measurements with a YieldStar metrology tool are presented for target-sizes down to 10 × 10 μm2. The μDBO technology enables selection of only the diffraction efficiency information from the grating by efficiently separating it from product structure reflections. Therefore, μDBO targets -even when located adjacent to product environment- give excellent correlation with 40 × 160 μm2 reference targets. Although significantly smaller than standard scribe-line targets, they can achieve total-measurement-uncertainty values of below 0.5 nm on a wide range of product layers. This shows that the new μDBO technique allows for accurate metrology on ultra small in-die targets, while retaining the excellent TMU performance of diffraction-based overlay metrology.

  4. Poor physical function in elderly women in low-level aged care is related to muscle strength rather than to measures of sarcopenia.

    PubMed

    Woods, Julie L; Iuliano-Burns, Sandra; King, Susannah J; Strauss, Boyd J; Walker, Karen Z

    2011-01-01

    To determine the prevalence of sarcopenia and investigate relationships among body composition, muscle strength, and physical function in elderly women in low-level aged care. Sixty-three ambulatory women (mean age 86 years) participated in this cross-sectional study where body composition was determined by dual energy X-ray absorptiometry (DXA); ankle, knee, and hip strength by the Nicholas Manual Muscle Tester; and physical function by 'timed up and go' (TUG) and walking speed (WS) over 6 meters. Body composition data from a female reference group (n = 62, mean age 29 years) provided cut-off values for defining sarcopenia. Elderly women had higher body mass index (P < 0.001), lower lean mass (P < 0.001), and higher fat mass (P < 0.01) than the young reference group. Only a small proportion (3.2%) had absolute sarcopenia (defined by appendicular skeletal muscle mass/height squared) whereas 37% had relative sarcopenia class II (defined by percentage skeletal muscle mass). Scores for TUG and WS indicated relatively poor physical function, yet these measures were not associated with muscle mass or indices of sarcopenia. In multivariate analysis, only hip abductor strength predicted both TUG and WS (both P = 0.01). Hip strength is a more important indicator of physical functioning than lean mass. Measurement of hip strength may therefore be a useful screening tool to detect those at risk of functional decline and requirement for additional care. Further longitudinal studies with a range of other strength measures are warranted.

  5. Fluid mechanics aspects of magnetic drug targeting.

    PubMed

    Odenbach, Stefan

    2015-10-01

    Experiments and numerical simulations using a flow phantom for magnetic drug targeting have been undertaken. The flow phantom is a half y-branched tube configuration where the main tube represents an artery from which a tumour-supplying artery, which is simulated by the side branch of the flow phantom, branches off. In the experiments a quantification of the amount of magnetic particles targeted towards the branch by a magnetic field applied via a permanent magnet is achieved by impedance measurement using sensor coils. Measuring the targeting efficiency, i.e. the relative amount of particles targeted to the side branch, for different field configurations one obtains targeting maps which combine the targeting efficiency with the magnetic force densities in characteristic points in the flow phantom. It could be shown that targeting efficiency depends strongly on the magnetic field configuration. A corresponding numerical model has been set up, which allows the simulation of targeting efficiency for variable field configuration. With this simulation good agreement of targeting efficiency with experimental data has been found. Thus, the basis has been laid for future calculations of optimal field configurations in clinical applications of magnetic drug targeting. Moreover, the numerical model allows the variation of additional parameters of the drug targeting process and thus an estimation of the influence, e.g. of the fluid properties on the targeting efficiency. Corresponding calculations have shown that the non-Newtonian behaviour of the fluid will significantly influence the targeting process, an aspect which has to be taken into account, especially recalling the fact that the viscosity of magnetic suspensions depends strongly on the magnetic field strength and the mechanical load.

  6. Optimal resource allocation for defense of targets based on differing measures of attractiveness.

    PubMed

    Bier, Vicki M; Haphuriwat, Naraphorn; Menoyo, Jaime; Zimmerman, Rae; Culpen, Alison M

    2008-06-01

    This article describes the results of applying a rigorous computational model to the problem of the optimal defensive resource allocation among potential terrorist targets. In particular, our study explores how the optimal budget allocation depends on the cost effectiveness of security investments, the defender's valuations of the various targets, and the extent of the defender's uncertainty about the attacker's target valuations. We use expected property damage, expected fatalities, and two metrics of critical infrastructure (airports and bridges) as our measures of target attractiveness. Our results show that the cost effectiveness of security investment has a large impact on the optimal budget allocation. Also, different measures of target attractiveness yield different optimal budget allocations, emphasizing the importance of developing more realistic terrorist objective functions for use in budget allocation decisions for homeland security.

  7. Adhesion strength of a living cell to various substrates measured using a cup-attached atomic force microscopy chip

    NASA Astrophysics Data System (ADS)

    Kim, Hyonchol; Ishibashi, Kenta; Matsuo, Kosuke; Kira, Atsushi; Onomura, Yui; Okada, Tomoko; Nakamura, Chikashi

    2018-03-01

    Cell adhesion strengths to various substrates were quantitatively measured using atomic force microscopy (AFM). A cup-shaped metal hemisphere was attached to the apex of the AFM cantilever, the “cup-chip” approached a cell (FP10SC2) to pick it up, the captured cell approached any one of six different substrates [gold (Au), nickel (Ni), bovine serum albumin (BSA), an amino group (NH2), poly(tetrafluoroethylene) (PTFE), and structured PTFE (sPTFE)], and the cell adhesion strength at the initial contact period was evaluated by detaching the cell from the substrate. The results obtained showed that the force needed to detach the cell from the NH2 substrate was more than 3-fold larger than that of metal substrates (Au and Ni), more than 15-fold larger than that of biochemically treated substrates (BSA), and more than 20-fold larger than that of hydrophobic substrates (PTFE and sPTFE). Using differences in adhesion strengths, a cell on a sPTFE substrate was picked up using a BSA-coated cup-chip, placed on a NH2 substrate, repeating this cell manipulation five times, and line patterning of cells was achieved. These results indicate that measurements of cell adhesion strength are fundamental to fabricate desired cell networks and the cup-chip is a useful tool for achieving easy cell manipulation.

  8. Isometric shoulder strength in young swimmers.

    PubMed

    McLaine, Sally J; Ginn, Karen A; Fell, James W; Bird, Marie-Louise

    2018-01-01

    The prevalence of shoulder pain in young swimmers is high. Shoulder rotation strength and the ratio of internal to external rotation strength have been reported as potential modifiable risk factors associated with shoulder pain. However, relative strength measures in elevated positions, which include flexion and extension, have not been established for the young swimmer. The aim of this study was to establish clinically useful, normative shoulder strength measures and ratios for swimmers (14-20 years) without shoulder pain. Cross-sectional, observational study. Swimmers (N=85) without a recent history of shoulder pain underwent strength testing of shoulder flexion and extension (in 140° abduction); and internal and external rotation (in 90° abduction). Strength tests were performed in supine using a hand-held dynamometer and values normalised to body weight. Descriptive statistics were calculated for strength and strength ratios (flexion:extension and internal:external rotation). Differences between groups (based on gender, history of pain, test and arm dominance) were explored using independent and paired t tests. Normative shoulder strength values and ratios were established for young swimmers. There was a significant difference (p<0.002) in relative strength between males and females for all tests with no differences in strength ratios. Relative strength of the dominant and non-dominant shoulders (except for extension); and for swimmers with and without a history of shoulder pain was not significantly different. A normal shoulder strength profile for the young swimmer has been established which provides a valuable reference for the clinician assessing shoulder strength in this population. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  9. Radiology Reports With Hyperlinks Improve Target Lesion Selection and Measurement Concordance in Cancer Trials.

    PubMed

    Machado, Laura B; Apolo, Andrea B; Steinberg, Seth M; Folio, Les R

    2017-02-01

    Radiology reports often lack the measurements of target lesions that are needed for oncology clinical trials. When available, the measurements in the radiology reports often do not match those in the records used to calculate therapeutic response. This study assessed the clinical value of hyperlinked tumor measurements in multimedia-enhanced radiology reports in the PACS and the inclusion of a radiologist assistant in the process of assessing tumor burden. We assessed 489 target lesions in 232 CT examinations of 71 patients with metastatic genitourinary cancer enrolled in two therapeutic trials. We analyzed target lesion selection and measurement concordance between oncology records (used to calculate therapeutic response) and two types of radiology reports in the PACS: multimedia-enhanced radiology reports and text-only reports. For statistical tests, we used the Wilcoxon signed rank, Wilcoxon rank sum test, and Fisher method to combine p values from the paired and unpaired results. The Fisher exact test was used to compare overall measurement concordance. Concordance on target lesion selection was greater for multimedia-enhanced radiology reports (78%) than the text-only reports (52%) (p = 0.0050). There was also improved overall measurement concordance with the multimedia-enhanced radiology reports (68%) compared with the text-only reports (38%) (p < 0.0001). Compared with text-only reports, hyperlinked multimedia-enhanced radiology reports improved concordance of target lesion selection and measurement with the measurements used to calculate therapeutic response.

  10. Industrial point source CO2 emission strength estimation with aircraft measurements and dispersion modelling.

    PubMed

    Carotenuto, Federico; Gualtieri, Giovanni; Miglietta, Franco; Riccio, Angelo; Toscano, Piero; Wohlfahrt, Georg; Gioli, Beniamino

    2018-02-22

    CO 2 remains the greenhouse gas that contributes most to anthropogenic global warming, and the evaluation of its emissions is of major interest to both research and regulatory purposes. Emission inventories generally provide quite reliable estimates of CO 2 emissions. However, because of intrinsic uncertainties associated with these estimates, it is of great importance to validate emission inventories against independent estimates. This paper describes an integrated approach combining aircraft measurements and a puff dispersion modelling framework by considering a CO 2 industrial point source, located in Biganos, France. CO 2 density measurements were obtained by applying the mass balance method, while CO 2 emission estimates were derived by implementing the CALMET/CALPUFF model chain. For the latter, three meteorological initializations were used: (i) WRF-modelled outputs initialized by ECMWF reanalyses; (ii) WRF-modelled outputs initialized by CFSR reanalyses and (iii) local in situ observations. Governmental inventorial data were used as reference for all applications. The strengths and weaknesses of the different approaches and how they affect emission estimation uncertainty were investigated. The mass balance based on aircraft measurements was quite succesful in capturing the point source emission strength (at worst with a 16% bias), while the accuracy of the dispersion modelling, markedly when using ECMWF initialization through the WRF model, was only slightly lower (estimation with an 18% bias). The analysis will help in highlighting some methodological best practices that can be used as guidelines for future experiments.

  11. A Systematic Review of Isometric Lingual Strength-Training Programs in Adults With and Without Dysphagia.

    PubMed

    McKenna, Victoria S; Zhang, Bin; Haines, Morgan B; Kelchner, Lisa N

    2017-05-17

    This systematic review summarizes the effects of isometric lingual strength training on lingual strength and swallow function in adult populations. Furthermore, it evaluates the designs of the reviewed studies and identifies areas of future research in isometric lingual strength training for dysphagia remediation. A comprehensive literature search of 3 databases and additional backward citation search identified 10 studies for inclusion in the review. The review reports and discusses the isometric-exercise intervention protocols, pre- and postintervention lingual-pressure data (maximum peak pressures and lingual-palatal pressures during swallowing), and oropharyngeal swallowing measures such as penetration-aspiration scales, oropharyngeal residue and duration, lingual volumes, and quality-of-life assessments. Studies reported gains in maximum peak lingual pressures following isometric lingual strength training for both healthy adults and select groups of individuals with dysphagia. However, due to the variability in study designs, it remains unclear whether strength gains generalize to swallow function. Although isometric lingual strength training is a promising intervention for oropharyngeal dysphagia, the current literature is too variable to confidently report specific therapeutic benefits. Future investigations should target homogenous patient populations and use randomized controlled trials to determine the efficacy of this treatment for individuals with dysphagia.

  12. Surface properties and bond strength measurements of N-vinylcaprolactam (NVC)-containing glass-ionomer cements.

    PubMed

    Moshaverinia, Alireza; Chee, Winston W; Brantley, William A; Schricker, Scott R

    2011-03-01

    N-vinylcaprolactam (NVC)-containing glass ionomers are promising dental restorative materials with improved mechanical properties; however, little information is available on other physical characteristics of these types of modified glass ionomers, especially their surface properties. Understanding the surface characteristics and behavior of glass ionomers is important for understanding their clinical behavior and predictability as dental restorative materials. The purpose of this study was to investigate the effect of NVC-containing terpolymers on the surface properties and bond strength to dentin of GIC (glass-ionomer cement), and to evaluate the effect of NVC-containing terpolymer as a dentin conditioner. The terpolymer of acrylic acid (AA)-itaconic acid (IA)-N-vinylcaprolactam (NVC) with a molar ratio of 8:1:1 (AA:IA:NVC) was synthesized by free radical polymerization and characterized using nuclear magnetic resonance ((1)H-NMR) and Fourier transform infrared spectroscopy (FTIR). The synthesized terpolymer was used in glass-ionomer cement formulations (Fuji IX GP). Ten disc-shaped specimens (12 × 1 mm) were mixed and fabricated at room temperature. Surface properties (wettability) of modified cements were studied by contact angle measurements as a function of time. Work of adhesion values of different surfaces were also determined. The effect of NVC-modified polyacid on the bond strength of glass-ionomer cement to dentin was investigated. The mean data obtained from contact angle and bonding strength measurements were subjected to t test and 2-way ANOVA (α=.05). NVC-modified glass-ionomer cements showed significantly (P<.05) lower contact angles (46 degrees) and higher work of adhesion (W(A)=60.33 erg/cm(2)) in comparison to commercially available Fuji IX GP (57 degrees and W(A)=53.01 erg/cm(2)). The wettability of dentin surfaces conditioned with NVC-containing terpolymer was significantly higher (P<.05) (22 degrees, WA=73.77 erg/cm(2)) than dentin

  13. Ballistic strength training compared with usual care for improving mobility following traumatic brain injury: protocol for a randomised, controlled trial.

    PubMed

    Williams, Gavin; Ada, Louise; Hassett, Leanne; Morris, Meg E; Clark, Ross; Bryant, Adam L; Olver, John

    2016-07-01

    Traumatic brain injury is the leading cause of disability in young adults aged 15 to 45 years. Mobility limitations are prevalent, and range in severity from interfering with basic day-to-day tasks to restricting participation in higher level social, leisure, employment and sporting activities. Despite the prevalence and severity of physical impairments, such as poor balance and spasticity, the main contributor to mobility limitations following traumatic brain injury is low muscle power generation. Strengthening exercises that are performed quickly are termed 'ballistic' as they are aimed at improving the rate of force production and, hence, muscle power. This is compared with conventional strength training, which is performed slowly and aims to improve maximum force production, yet has limited impact on mobility. In people recovering from traumatic brain injury: (1) is a 12-week ballistic strength-training program targeting the three muscle groups critical for walking more effective than usual care at improving mobility, strength and balance; and (2) does improved mobility translate to better health-related quality of life? A prospective, multi-centre, randomised, single-blind trial with concealed allocation will be conducted. Participants will be patients with a neurologically based movement disorder affecting mobility as a result of traumatic brain injury. Patients will be recruited during the acute phase of rehabilitation (n=166), from brain injury units in large metropolitan hospitals in Melbourne and Sydney, Australia. For 12 weeks, participants in the experimental group will have three 60-minute sessions of usual physiotherapy intervention replaced by three 60-minute sessions of strength training (ballistic strength, gait). The three key muscle groups responsible for forward propulsion will be targeted: ankle plantarflexors, hip flexors and the hip extensors. Initial loads will be low, to facilitate high contraction velocities. Progression to higher loads

  14. New Accurate Oscillator Strengths and Electron Excitation Collision Strengths for N1

    NASA Technical Reports Server (NTRS)

    Tayal, S. S.

    2006-01-01

    The nonorthogonal orbitals technique in a multiconfiguration Hartree-Fock approach is used to calculate oscillator strengths and transition probabilities of N(I) lines. The relativistic effects are allowed by means of Breit-Pauli operators. The length and velocity forms of oscillator strengths show good agreement for most transitions. The B-spline R-matrix with pseudostates approach has been used to calculate electron excitation collision strengths and rates. The nonorthogonal orbitals are used for an accurate description of both target wave functions and the R-matrix basis functions. The 24 spectroscopic bound and autoionizing states together with 15 pseudostates are included in the close-coupling expansion. The collision strengths for transitions between fine-structure levels are calculated by transforming the LS-coupled K-matrices to K-matrices in an intermediate coupling scheme. Thermally averaged collision strengths have been determined by integrating collision strength over a Maxwellian distribution of electron energies over a temperature range suitable for the modeling of astrophysical plasmas. The oscillator strengths and thermally averaged collision strengths are presented for transitions between the fine-structure levels of the 2s(sup 2)p(sup 3) (sup 4)S(sup 0), (sup 2)D(sup 0), (sup 2)P(sup 0), 2s2p(sup 4) (sup 4)P, 2s(sup 2)2p(sup 2)3s (sup 4)P, and (sup 2)P terms and from these levels to the levels of the 2s(sup 2)2p(sup 2)3p (sup 2)S(sup 0), (sup 4)D(sup 0), (sup 4)P(sup 0), (sup 4)S(sup 0), (sup 2)D(sup 0), (sup 2)P(sup 0),2s(sup 2)2p(sup 2)3s(sup 2)D, 2s(sup 2)2p(sup 2)4s(sup 4)P, (sup 2)P, 2s(sup 2)2p(sup 2)3d(sup 2)P, (sup 4)F,(sup 2)F,(sup 4)P, (sup 4)D, and (sup 2)D terms. Thermally averaged collision strengths are tabulated over a temperature range from 500 to 50,000 K.

  15. 47 CFR 27.55 - Power strength limits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 2 2011-10-01 2011-10-01 false Power strength limits. 27.55 Section 27.55... COMMUNICATIONS SERVICES Technical Standards § 27.55 Power strength limits. (a) Field strength limits. For the following bands, the predicted or measured median field strength at any location on the geographical border...

  16. Measuring Plasma Formation Field Strength and Current Loss in Pulsed Power Diodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnston, Mark D.; Patel, Sonal G.; Falcon, Ross Edward

    This LDRD investigated plasma formation, field strength, and current loss in pulsed power diodes. In particular the Self-Magnetic Pinch (SMP) e-beam diode was studied on the RITS-6 accelerator. Magnetic fields of a few Tesla and electric fields of several MV/cm were measured using visible spectroscopy techniques. The magnetic field measurements were then used to determine the current distribution in the diode. This distribution showed that significant beam current extends radially beyond the few millimeter x-ray focal spot diameter. Additionally, shielding of the magnetic field due to dense electrode surface plasmas was observed, quantified, and found to be consistent with themore » calculated Spitzer resistivity. In addition to the work on RITS, measurements were also made on the Z-machine looking to quantify plasmas within the power flow regions. Measurements were taken in the post-hole convolute and final feed gap regions on Z. Dopants were applied to power flow surfaces and measured spectroscopically. These measurements gave species and density/temperature estimates. Preliminary B-field measurements in the load region were attempted as well. Finally, simulation work using the EMPHASIS, electromagnetic particle in cell code, was conducted using the Z MITL conditions. The purpose of these simulations was to investigate several surface plasma generations models under Z conditions for comparison with experimental data.« less

  17. 47 CFR 90.671 - Field strength limits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Field strength limits. 90.671 Section 90.671... 896-901/935-940 Mhz Band § 90.671 Field strength limits. The predicted or measured field strength at... all bordering MTA licensees agree to a higher field strength. MTA licensees are also required to...

  18. 47 CFR 90.671 - Field strength limits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Field strength limits. 90.671 Section 90.671... 896-901/935-940 Mhz Band § 90.671 Field strength limits. The predicted or measured field strength at... all bordering MTA licensees agree to a higher field strength. MTA licensees are also required to...

  19. Correlation between compressive strength and ultrasonic pulse velocity of high strength concrete incorporating chopped basalt fibre

    NASA Astrophysics Data System (ADS)

    Shafiq, Nasir; Fadhilnuruddin, Muhd; Elshekh, Ali Elheber Ahmed; Fathi, Ahmed

    2015-07-01

    Ultrasonic pulse velocity (UPV), is considered as the most important test for non-destructive techniques that are used to evaluate the mechanical characteristics of high strength concrete (HSC). The relationship between the compressive strength of HSC containing chopped basalt fibre stands (CBSF) and UPV was investigated. The concrete specimens were prepared using a different ratio of CBSF as internal strengthening materials. The compressive strength measurements were conducted at the sample ages of 3, 7, 28, 56 and 90 days; whilst, the ultrasonic pulse velocity was measured at 28 days. The result of HSC's compressive strength with the chopped basalt fibre did not show any improvement; instead, it was decreased. The UPV of the chopped basalt fibre reinforced concrete has been found to be less than that of the control mix for each addition ratio of the basalt fibre. A relationship plot is gained between the cube compressive strength for HSC and UPV with various amounts of chopped basalt fibres.

  20. Autism Severity and Muscle Strength: A Correlation Analysis

    ERIC Educational Resources Information Center

    Kern, Janet K.; Geier, David A.; Adams, James B.; Troutman, Melissa R.; Davis, Georgia; King, Paul G.; Young, John L.; Geier, Mark R.

    2011-01-01

    The current study examined the relationship between muscle strength, as measured by hand grip strength, and autism severity, as measured by the Childhood Autism Rating Scale (CARS). Thirty-seven (37) children with a diagnosis of autism spectrum disorder (ASD) were evaluated using the CARS and then tested for hand muscle strength using a hand grip…

  1. Notched Strength Allowables and Inplane Shear Strength of AS4/VRM-34 Textile Laminates

    NASA Technical Reports Server (NTRS)

    Grenoble, Ray W.; Johnston, William M.

    2013-01-01

    Notched and unnotched strength allowables were developed for a textile composite to provide input data to analytical structural models based on the Pultruded Rod Stiffened Efficient Unitized Structure (PRSEUS) concept. Filled-hole tensile strength, filled-hole compressive strength, and inplane shear strength along stitch lines have been measured. The material system evaluated in this study is based on warp-knitted preforms of AS4 carbon fibers and VRM-34 epoxy resin, which have been processed via resin infusion and oven curing. All specimens were tested in as-fabricated (dry) condition. Filled-hole strengths were evaluated with and without through-thickness stitching. The effects of scaling on filled-hole tensile strength were evaluated by testing specimens in two widths, but with identical width / hole-diameter ratios. Inplane shear specimens were stitched in two configurations, and two specimen thicknesses were tested for each stitch configuration.

  2. Muscle strength and soft tissue composition as measured by dual energy x-ray absorptiometry in women aged 18-87 years.

    PubMed

    Madsen, O R; Lauridsen, U B; Hartkopp, A; Sørensen, O H

    1997-01-01

    Dual energy x-ray absorptiometry (DEXA) offers the possibility of assessing regional soft tissue composition, i.e. lean mass (LM) and fat mass: LM may be considered a measure of muscle mass. We examined age-related differences in LM, percentage fat (%fat) and muscle strength in 100 healthy non-athletic women aged 18-87 years. Relationships between muscle strength and leg LM in 20 elite female weight lifters and in 18 inactive women with previous hip fractures were also studied. The LM and %fat of the whole body, trunk, arms and legs were derived from a whole body DEXA scan. Isokinetic knee extensor strength (KES) and flexor strength (KFS) at 30 degrees.s-1 were assessed using an isokinetic dynamometer. The women aged 71-87 years had 35% lower KES and KFS than the women aged 18-40 years (P < 0.0001). Differences in LM were less pronounced. The LM of the legs, for instance, was 15% lower in the old than in the young women (P < 0.0001). In a multiple regression analysis with age, body mass, height and leg LM or KES as independent variables and KES or leg LM as the dependent variable, age was the most important predictor of KES (r(partial) = -0.74, P < 0.0001). The same applied to KFS. Body mass, not age, was the most important predictor of leg LM (r(partial) = 0.65, P < 0.0001) and of LM at all other measurement sites. The LM measured at different regions decreased equally with increasing age. The KES:leg LM ratio was negatively correlated with age (r = -0.70, P < 0.0001). The weight lifters had significantly higher KES:leg LM ratios than age-matched controls (+ 12%, P < 0.0001) and vice versa for the women with previous hip fractures (-36%, P < 0.0001). In conclusion, from our study it would seem that in healthy nonathletic women, age is a more important determinant of muscle strength than is LM as measured by DEXA. Muscle strengthening exercises and inactivity seem to have a considerably stronger influence on muscle strength than on LM.

  3. Poor physical function in elderly women in low-level aged care is related to muscle strength rather than to measures of sarcopenia

    PubMed Central

    Woods, Julie L; Iuliano-Burns, Sandra; King, Susannah J; Strauss, Boyd J; Walker, Karen Z

    2011-01-01

    Purpose: To determine the prevalence of sarcopenia and investigate relationships among body composition, muscle strength, and physical function in elderly women in low-level aged care. Subjects and methods: Sixty-three ambulatory women (mean age 86 years) participated in this cross-sectional study where body composition was determined by dual energy X-ray absorptiometry (DXA); ankle, knee, and hip strength by the Nicholas Manual Muscle Tester; and physical function by ‘timed up and go’ (TUG) and walking speed (WS) over 6 meters. Body composition data from a female reference group (n = 62, mean age 29 years) provided cut-off values for defining sarcopenia. Results: Elderly women had higher body mass index (P < 0.001), lower lean mass (P < 0.001), and higher fat mass (P < 0.01) than the young reference group. Only a small proportion (3.2%) had absolute sarcopenia (defined by appendicular skeletal muscle mass/height squared) whereas 37% had relative sarcopenia class II (defined by percentage skeletal muscle mass). Scores for TUG and WS indicated relatively poor physical function, yet these measures were not associated with muscle mass or indices of sarcopenia. In multivariate analysis, only hip abductor strength predicted both TUG and WS (both P = 0.01). Conclusion: Hip strength is a more important indicator of physical functioning than lean mass. Measurement of hip strength may therefore be a useful screening tool to detect those at risk of functional decline and requirement for additional care. Further longitudinal studies with a range of other strength measures are warranted. PMID:21472094

  4. Intrarater reliability of hand held dynamometry in measuring lower extremity isometric strength using a portable stabilization device.

    PubMed

    Jackson, Steven M; Cheng, M Samuel; Smith, A Russell; Kolber, Morey J

    2017-02-01

    Hand held dynamometry (HHD) is a more objective way to quantify muscle force production (MP) compared to traditional manual muscle testing. HHD reliability can be negatively impacted by both the strength of the tester and the subject particularly in the lower extremities due to larger muscle groups. The primary aim of this investigation was to assess intrarater reliability of HHD with use of a portable stabilization device for lower extremity MP in an athletic population. Isometric lower extremity strength was measured for bilateral lower extremities including hip abductors, external rotators, adductors, knee extensors, and ankle plantar flexors was measured in a sample of healthy recreational runners (8 male, 7 females, = 30 limbs) training for a marathon. These measurements were assessed using an intrasession intrarater reliability design. Intraclass correlation coefficients (ICC) were calculated using 3,1 model based on the single rater design. The standard error of measurement (SEM) for each muscle group was also calculated. ICC were excellent ranging from ICC (3,1) = 0.93-0.98 with standard error of measurements ranging from 0.58 to 17.2 N. This study establishes the use of a HHD with a portable stabilization device as demonstrating good reliability within testers for measuring lower extremity muscle performance in an active healthy population. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Patterns of Hand Grip Strength and Detection of Strength Loss in Patients Undergoing Bone Marrow Transplantation: A Feasibility Study.

    PubMed

    Sayre, Cindy A; Belza, Basia; Shannon Dorcy, Kathleen; Phelan, Elizabeth; Whitney, JoAnne D

    2017-09-01

    To determine the feasibility of measuring hand grip strength (HGS) daily in a population of recipients of bone marrow transplantation (BMT), to describe changes in strength measured by HGS, and to describe relationships between laboratory values (hematocrit, hemoglobin, and absolute neutrophil count) and HGS.
. Prospective, longitudinal, repeated measures, within subject.
. Inpatient units at the University of Washington Medical Center in Seattle.
. 33 patients admitted in preparation for BMT or for complications from BMT.
. HGS measured on admission and daily.
. HGS, absolute neutrophil count, hemoglobin, and hematocrit.
. Participants found HGS testing to be relatively easy. Average time to complete testing was 7.2 minutes (SD = 1.95). Nineteen experienced 20% or greater decline in HGS during hospitalization, with nine experiencing decline during the conditioning phase. Age, gender, and hemoglobin correlated with HGS. Strength loss was more likely in those undergoing allogeneic compared to autologous BMT.
. A majority of patients experienced strength decline during BMT, with a subgroup declining during conditioning. A positive relationship existed between HGS and hemoglobin and hematocrit in participants admitted for conditioning for BMT.
. Weakness increases risk for falls. Patients may experience as much as 50% strength loss during the course of hospitalization for BMT. Strength loss occurs in the conditioning phase for some patients.

  6. CADDIS Volume 2. Sources, Stressors and Responses: Ionic Strength

    EPA Pesticide Factsheets

    Introduction to the ionic strength module, when to list ionic strength as a candidate cause, ways to measure ionic strength, simple and detailed conceptual diagrams for ionic strength, ionic strength module references and literature reviews.

  7. Gadolinium-148 and other spallation production cross section measurements for accelerator target facilities

    NASA Astrophysics Data System (ADS)

    Kelley, Karen Corzine

    At the Los Alamos Neutron Science Center accelerator complex, protons are accelerated to 800 MeV and directed to two tungsten targets, Target 4 at the Weapons Neutron Research facility and the 1L target at the Lujan Center. The Department of Energy requires hazard classification analyses to be performed on these targets and places limits on certain radionuclide inventories in the targets to avoid characterizing the facilities as "nuclear facilities." Gadolinium-148 is a radionuclide created from the spallation of tungsten. Allowed isotopic inventories are particularly low for this isotope because it is an alpha-particle emitter with a 75-year half-life. The activity level of Gadolinium-148 is low, but it encompasses almost two-thirds of the total dose burden for the two tungsten targets based on present yield estimates. From a hazard classification standpoint, this severely limits the lifetime of these tungsten targets. The cross section is not well-established experimentally and this is the motivation for measuring the Gadolinium-148 production cross section from tungsten. In a series of experiments at the Weapons Neutron Research facility, Gadolinium-148 production was measured for 600- and 800-MeV protons on tungsten, tantalum, and gold. These experiments used 3 mum thin tungsten, tantalum, and gold foils and 10 mum thin aluminum activation foils. In addition, spallation yields were determined for many short-lived and long-lived spallation products with these foils using gamma and alpha spectroscopy and compared with predictions of the Los Alamos National Laboratory codes CEM2k+GEM2 and MCNPX. The cumulative Gadolinium-148 production cross section measured from tantalum, tungsten, and gold for incident 600-MeV protons were 15.2 +/- 4.0, 8.31 +/- 0.92, and 0.591 +/- 0.155, respectively. The average production cross sections measured at 800 MeV were 28.6 +/- 3.5, 19.4 +/- 1.8, and 3.69 +/- 0.50 for tantalum, tungsten, and gold, respectively. These cumulative

  8. Absolute Position of Targets Measured Through a Chamber Window Using Lidar Metrology Systems

    NASA Technical Reports Server (NTRS)

    Kubalak, David; Hadjimichael, Theodore; Ohl, Raymond; Slotwinski, Anthony; Telfer, Randal; Hayden, Joseph

    2012-01-01

    Lidar is a useful tool for taking metrology measurements without the need for physical contact with the parts under test. Lidar instruments are aimed at a target using azimuth and elevation stages, then focus a beam of coherent, frequency modulated laser energy onto the target, such as the surface of a mechanical structure. Energy from the reflected beam is mixed with an optical reference signal that travels in a fiber path internal to the instrument, and the range to the target is calculated based on the difference in the frequency of the returned and reference signals. In cases when the parts are in extreme environments, additional steps need to be taken to separate the operator and lidar from that environment. A model has been developed that accurately reduces the lidar data to an absolute position and accounts for the three media in the testbed air, fused silica, and vacuum but the approach can be adapted for any environment or material. The accuracy of laser metrology measurements depends upon knowing the parameters of the media through which the measurement beam travels. Under normal conditions, this means knowledge of the temperature, pressure, and humidity of the air in the measurement volume. In the past, chamber windows have been used to separate the measuring device from the extreme environment within the chamber and still permit optical measurement, but, so far, only relative changes have been diagnosed. The ability to make accurate measurements through a window presents a challenge as there are a number of factors to consider. In the case of the lidar, the window will increase the time-of-flight of the laser beam causing a ranging error, and refract the direction of the beam causing angular positioning errors. In addition, differences in pressure, temperature, and humidity on each side of the window will cause slight atmospheric index changes and induce deformation and a refractive index gradient within the window. Also, since the window is a

  9. Assessment of short/long term electric field strength measurements for a pilot district

    NASA Astrophysics Data System (ADS)

    Kurnaz, Cetin; Yildiz, Dogan; Karagol, Serap

    2018-03-01

    The level of electromagnetic radiation (EMR) exposure increases day by day as natural consequences of technological developments. In recent years, the increasing use of cellular systems has made it necessary to measure and evaluate EMR originating from base stations. In this study, broadband and band selective electric field strength (E) measurements were taken at four different times in order to evaluate the change of short term E in Atakum district of Samsun, Turkey. The measurements were collected from 46 different locations using a SRM 3006 and a PMM 8053 EMR meter in a band from 100 kHz to 3 GHz, and the maximum E (Emax) and the average E (Eavg) were recorded. The highest values have been noticed in these measurements at 9.45 V/m and 17.53 V/m for Eavg and Emax respectively. Apart from these measurements, 24 hour long term E measurements were taken at a location where the highest value was observed and analyzed, to observe the change of Es during a day. At the end of the study, a tentative mathematical model that helps in computing the total E of the medium with 95% accuracy, was obtained.

  10. At-home resistance tubing strength training increases shoulder strength in the trained and untrained limb.

    PubMed

    Magnus, C R A; Boychuk, K; Kim, S Y; Farthing, J P

    2014-06-01

    The purpose was to determine if an at-home resistance tubing strength training program on one shoulder (that is commonly used in rehabilitation settings) would produce increases in strength in the trained and untrained shoulders via cross-education. Twenty-three participants were randomized to TRAIN (strength-trained one shoulder; n = 13) or CONTROL (no intervention; n = 10). Strength training was completed at home using resistance tubing and consisted of maximal shoulder external rotation, internal rotation, scaption, retraction, and flexion 3 days/week for 4 weeks. Strength was measured via handheld dynamometry and muscle size measured via ultrasound. For external rotation strength, the trained (10.9 ± 10.9%) and untrained (12.7 ± 9.6%) arm of TRAIN was significantly different than CONTROL (1.6 ± 13.2%; -2.7 ± 12.3%; pooled across arm; P < 0.05). For internal rotation strength, the trained (14.8 ± 11.3%) and untrained (14.6 ± 10.1%) arm of TRAIN was significantly different than CONTROL (6.4 ± 11.2%; 5.1 ± 8.8%; pooled across arm; P < 0.05). There were no significant differences for scaption strength (P = 0.056). TRAIN significantly increased muscle size in the training arm of the supraspinatus (1.90 ± 0.32 to 1.99 ± 0.31 cm), and the anterior deltoid (1.08 ± 0.37 to 1.21 ± 0.39 cm; P < 0.05). This study suggests that an at-home resistance tubing training program on one limb can produce increases in strength in both limbs, and has implications for rehabilitation after unilateral shoulder injuries. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Size and Strength: Do We Need Both to Measure Vocabulary Knowledge?

    ERIC Educational Resources Information Center

    Laufer, B.; Elder, C.; Hill, K.; Congdon, P.

    2004-01-01

    This article describes the development and validation of a test of vocabulary size and strength. The first part of the article sets out the theoretical rationale for the test, and describes how the size and strength constructs have been conceptualized and operationalized. The second part of the article focusses on the process of test validation,…

  12. Bone strength measured by peripheral quantitative computed tomography and the risk of nonvertebral fractures: the osteoporotic fractures in men (MrOS) study.

    PubMed

    Sheu, Yahtyng; Zmuda, Joseph M; Boudreau, Robert M; Petit, Moira A; Ensrud, Kristine E; Bauer, Douglas C; Gordon, Christopher L; Orwoll, Eric S; Cauley, Jane A

    2011-01-01

    Many fractures occur in individuals without osteoporosis defined by areal bone mineral density (aBMD). Inclusion of other aspects of skeletal strength may be useful in identifying at-risk subjects. We used surrogate measures of bone strength at the radius and tibia measured by peripheral quantitative computed tomography (pQCT) to evaluate their relationships with nonvertebral fracture risk. Femoral neck (FN) aBMD, measured by dual-energy X-ray absorptiometry (DXA), also was included. The study population consisted of 1143 white men aged 69+ years with pQCT measures at the radius and tibia from the Minneapolis and Pittsburgh centers of the Osteoporotic Fractures in Men (MrOS) study. Principal-components analysis and Cox proportional-hazards modeling were used to identify 21 of 58 pQCT variables with a major contribution to nonvertebral incident fractures. After a mean 2.9 years of follow-up, 39 fractures occurred. Men without incident fractures had significantly greater bone mineral content, cross-sectional area, and indices of bone strength than those with fractures by pQCT. Every SD decrease in the 18 of 21 pQCT parameters was significantly associated with increased fracture risk (hazard ration ranged from 1.4 to 2.2) independent of age, study site, body mass index (BMI), and FN aBMD. Using area under the receiver operation characteristics curve (AUC), the combination of FN aBMD and three radius strength parameters individually increased fracture prediction over FN aBMD alone (AUC increased from 0.73 to 0.80). Peripheral bone strength measures are associated with fracture risk and may improve our ability to identify older men at high risk of fracture. © 2011 American Society for Bone and Mineral Research.

  13. Measurements of the Stellar Wind Strengths of Planet-Hosting G- and K-Type Stars

    NASA Astrophysics Data System (ADS)

    Edelman, Eric; Redfield, S.; Wood, B.; Linsky, J.; Mueller, H. R.

    2014-01-01

    Voyager 1 has recently crossed the heliosphere, where the solar wind meets the material of the interstellar medium. With line of sight spectral information provided by the STIS on Hubble, the analogous boundary around other stars, which is known as an astrosphere, can be detected. We are conducting a thorough analysis of MgII, FeII, DI, and HI Lyman-alpha absorption along the lines of sight to a sample of nearby K and G stars in order to obtain and use astrospheric detections to estimate stellar wind strengths, and to study their effects upon exoplanetary atmospheres. Each astrospheric measurement is obtained by careful examination and reconstruction of the Lyman-alpha emission feature, which ultimately provides an estimate of the neutral hydrogen column density associated with a star’s astrosphere. The amount of neutral hydrogen in that region is highly dependent on the stellar wind strength of the host star, and is one of the scant few methods available today for measuring that quantity. If stellar winds are strong enough, they can be responsible for stripping a nearby planet of its atmosphere, as was potentially the case with Mars and our Sun approximately 4 billion years ago. Increasing the sample size of measurements of stellar wind strengths for K and G type stars will allow for us to more accurately determine the influence of solar-type host stars on their respective exoplanetary systems. Included in our sample are the stars HD9826 and HD192310, which both have confirmed exoplanets in orbit. This project includes the reconstructions of the Lyman-alpha emission feature along the lines of sight to a sample of nearby stars, with a determination of whether or not astrospheric or heliospheric absorption is detected in each instance, with hydrogen column densities for positive detections. We would like to acknowledge NASA HST Grant GO-12475 awarded by the Space Telescope Science Institute, which is operated by the Association of Universities for Research in

  14. Fabrication of 94Zr thin target for recoil distance doppler shift method of lifetime measurement

    NASA Astrophysics Data System (ADS)

    Gupta, C. K.; Rohilla, Aman; Abhilash, S. R.; Kabiraj, D.; Singh, R. P.; Mehta, D.; Chamoli, S. K.

    2014-11-01

    A thin isotopic 94Zr target of thickness 520 μg /cm2 has been prepared for recoil distance Doppler shift method (RDM) lifetime measurement by using an electron beam deposition method on tantalum backing of 3.5 mg/cm2 thickness at Inter University Accelerator Center (IUAC), New Delhi. To meet the special requirement of smoothness of surface for RDM lifetime measurement and also to protect the outer layer of 94Zr from peeling off, a very thin layer of gold has been evaporated on a 94Zr target on a specially designed substrate holder. In all, 143 mg of 99.6% enriched 94Zr target material was utilized for the fabrication of 94Zr targets. The target has been successfully used in a recent RDM lifetime measurement experiment at IUAC.

  15. The Importance of Muscular Strength: Training Considerations.

    PubMed

    Suchomel, Timothy J; Nimphius, Sophia; Bellon, Christopher R; Stone, Michael H

    2018-04-01

    This review covers underlying physiological characteristics and training considerations that may affect muscular strength including improving maximal force expression and time-limited force expression. Strength is underpinned by a combination of morphological and neural factors including muscle cross-sectional area and architecture, musculotendinous stiffness, motor unit recruitment, rate coding, motor unit synchronization, and neuromuscular inhibition. Although single- and multi-targeted block periodization models may produce the greatest strength-power benefits, concepts within each model must be considered within the limitations of the sport, athletes, and schedules. Bilateral training, eccentric training and accentuated eccentric loading, and variable resistance training may produce the greatest comprehensive strength adaptations. Bodyweight exercise, isolation exercises, plyometric exercise, unilateral exercise, and kettlebell training may be limited in their potential to improve maximal strength but are still relevant to strength development by challenging time-limited force expression and differentially challenging motor demands. Training to failure may not be necessary to improve maximum muscular strength and is likely not necessary for maximum gains in strength. Indeed, programming that combines heavy and light loads may improve strength and underpin other strength-power characteristics. Multiple sets appear to produce superior training benefits compared to single sets; however, an athlete's training status and the dose-response relationship must be considered. While 2- to 5-min interset rest intervals may produce the greatest strength-power benefits, rest interval length may vary based an athlete's training age, fiber type, and genetics. Weaker athletes should focus on developing strength before emphasizing power-type training. Stronger athletes may begin to emphasize power-type training while maintaining/improving their strength. Future research should

  16. Neutron measurements from beam-target reactions at the ELISE neutral beam test facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xufei, X., E-mail: xiexufei@pku.edu.cn; Fan, T.; Nocente, M.

    2014-11-15

    Measurements of 2.5 MeV neutron emission from beam-target reactions performed at the ELISE neutral beam test facility are presented in this paper. The measurements are used to study the penetration of a deuterium beam in a copper dump, based on the observation of the time evolution of the neutron counting rate from beam-target reactions with a liquid scintillation detector. A calculation based on a local mixing model of deuterium deposition in the target up to a concentration of 20% at saturation is used to evaluate the expected neutron yield for comparison with data. The results are of relevance to understandmore » neutron emission associated to beam penetration in a solid target, with applications to diagnostic systems for the SPIDER and MITICA Neutral Beam Injection prototypes.« less

  17. Indirect monitoring shot-to-shot shock waves strength reproducibility during pump-probe experiments

    NASA Astrophysics Data System (ADS)

    Pikuz, T. A.; Faenov, A. Ya.; Ozaki, N.; Hartley, N. J.; Albertazzi, B.; Matsuoka, T.; Takahashi, K.; Habara, H.; Tange, Y.; Matsuyama, S.; Yamauchi, K.; Ochante, R.; Sueda, K.; Sakata, O.; Sekine, T.; Sato, T.; Umeda, Y.; Inubushi, Y.; Yabuuchi, T.; Togashi, T.; Katayama, T.; Yabashi, M.; Harmand, M.; Morard, G.; Koenig, M.; Zhakhovsky, V.; Inogamov, N.; Safronova, A. S.; Stafford, A.; Skobelev, I. Yu.; Pikuz, S. A.; Okuchi, T.; Seto, Y.; Tanaka, K. A.; Ishikawa, T.; Kodama, R.

    2016-07-01

    We present an indirect method of estimating the strength of a shock wave, allowing on line monitoring of its reproducibility in each laser shot. This method is based on a shot-to-shot measurement of the X-ray emission from the ablated plasma by a high resolution, spatially resolved focusing spectrometer. An optical pump laser with energy of 1.0 J and pulse duration of ˜660 ps was used to irradiate solid targets or foils with various thicknesses containing Oxygen, Aluminum, Iron, and Tantalum. The high sensitivity and resolving power of the X-ray spectrometer allowed spectra to be obtained on each laser shot and to control fluctuations of the spectral intensity emitted by different plasmas with an accuracy of ˜2%, implying an accuracy in the derived electron plasma temperature of 5%-10% in pump-probe high energy density science experiments. At nano- and sub-nanosecond duration of laser pulse with relatively low laser intensities and ratio Z/A ˜ 0.5, the electron temperature follows Te ˜ Ilas2/3. Thus, measurements of the electron plasma temperature allow indirect estimation of the laser flux on the target and control its shot-to-shot fluctuation. Knowing the laser flux intensity and its fluctuation gives us the possibility of monitoring shot-to-shot reproducibility of shock wave strength generation with high accuracy.

  18. Relationship between thin-film bond strength as measured by a scratch test, and indentation hardness for bonding agents.

    PubMed

    Kusakabe, Shusuke; Rawls, H Ralph; Hotta, Masato

    2016-03-01

    To evaluate thin-film bond strength between a bonding agent and human dentin, using a scratch test, and the characteristics and accuracy of measurement. One-step bonding agents (BeautiBond; Bond Force; Adper Easy Bond; Clearfil tri-S Bond) and two-step bonding agents (Cleafil SE Bond; FL-Bond II) were investigated in this study. Flat dentin surfaces were prepared for extracted human molars. The dentin surfaces were ground and bonding agents were applied and light cured. The thin-film bond strength test of the specimens was evaluated by the critical load at which the coated bonding agent failed and dentin appeared. The scratch mark sections were then observed under a scanning electron microscope. Indentation hardness was evaluated by the variation in depth under an applied load of 10gf. Data were compared by one-way ANOVA with the Scheffé's post hoc multiple comparison test (p<0.05). In addition, thin-film bond strength and indentation hardness were analyzed using analysis of correlation and covariance. The thin-film bond strength of two-step bonding agents were found to be significantly higher than that of one-step bonding agents with small standard deviations. Scratch marks consistently showed adhesive failure in the vicinity of the bonding agent/dentin interface. The indentation hardness showed a trend that two-step bonding agents have greater hardness than one-step bonding agents. A moderately significant correlation (r(2)=0.31) was found between thin-film bond strength and indentation hardness. Thin-film bond strength test is a valid and reliable means of evaluating bond strength in the vicinity of the adhesive interface and is more accurate than other methods currently in use. Further, the thin-film bond strength is influenced by the hardness of the cued bonding agent. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  19. Creatine Supplementation Associated or Not with Strength Training upon Emotional and Cognitive Measures in Older Women: A Randomized Double-Blind Study

    PubMed Central

    Alves, Christiano Robles Rodrigues; Merege Filho, Carlos Alberto Abujabra; Benatti, Fabiana Braga; Brucki, Sonia; Pereira, Rosa Maria R.; de Sá Pinto, Ana Lucia; Lima, Fernanda Rodrigues; Roschel, Hamilton; Gualano, Bruno

    2013-01-01

    Purpose To assess the effects of creatine supplementation, associated or not with strength training, upon emotional and cognitive measures in older woman. Methods This is a 24-week, parallel-group, double-blind, randomized, placebo-controlled trial. The individuals were randomly allocated into one of the following groups (n=14 each): 1) placebo, 2) creatine supplementation, 3) placebo associated with strength training or 4) creatine supplementation associated with strength training. According to their allocation, the participants were given creatine (4 x 5 g/d for 5 days followed by 5 g/d) or placebo (dextrose at the same dosage) and were strength trained or not. Cognitive function, assessed by a comprehensive battery of tests involving memory, selective attention, and inhibitory control, and emotional measures, assessed by the Geriatric Depression Scale, were evaluated at baseline, after 12 and 24 weeks of the intervention. Muscle strength and food intake were evaluated at baseline and after 24 weeks. Results After the 24-week intervention, both training groups (ingesting creatine supplementation and placebo) had significant reductions on the Geriatric Depression Scale scores when compared with the non-trained placebo group (p = 0.001 and p = 0.01, respectively) and the non-trained creatine group (p < 0.001 for both comparison). However, no significant differences were observed between the non-trained placebo and creatine (p = 0.60) groups, or between the trained placebo and creatine groups (p = 0.83). Both trained groups, irrespective of creatine supplementation, had better muscle strength performance than the non-trained groups. Neither strength training nor creatine supplementation altered any parameter of cognitive performance. Food intake remained unchanged. Conclusion Creatine supplementation did not promote any significant change in cognitive function and emotional parameters in apparently healthy older individuals. In addition, strength training per se

  20. Determination of erosion thresholds and aeolian dune stabilization mechanisms via robotic shear strength measurements

    NASA Astrophysics Data System (ADS)

    Qian, F.; Lee, D. B.; Bodek, S.; Roberts, S.; Topping, T. T.; Robele, Y.; Koditschek, D. E.; Jerolmack, D. J.

    2017-12-01

    Understanding the parameters that control the spatial variation in aeolian soil erodibility is crucial to the development of sediment transport models. Currently, in-situ measurements of erodibility are time consuming and lack robustness. In an attempt to remedy this issue, we perform field and laboratory tests to determine the suitability of a novel mechanical shear strength method to assess soil erodibility. These tests can be performed quickly ( 1 minute) by a semi-autonomous robot using its direct-drive leg, while environmental controls such as soil moisture and grain size are simultaneously characterized. The robot was deployed at White Sands National Monument to delineate and understand erodibility gradients at two different scales: (1) from dry dune crest to moist interdune (distance 10s m), where we determined that shear strength increases by a factor of three with increasing soil moisture; and (2) from barren barchan dunes to vegetated and crusted parabolics downwind (distance 5 km), where we found that shear strength was enhanced by a factor of two relative to loose sand. Interestingly, shear strength varied little from carbonate-crusted dune surfaces to bio-crust covered interdunes in the downwind parabolic region, indicating that varied surface crusts contribute similarly to erosion resistance. To isolate the control of soil moisture on erodibility, we performed laboratory experiments in a sandbox. These results verify that the observed increase in soil erodibility from barchan crest to interdune at White Sands is dominated by soil moisture, and the variation in parabolic dune and barchan interdune areas results from a combination of soil moisture, bio-activity, and crust development. This study highlights that spatial variation of soil erodibility in arid environments is large enough to significantly affect sediment transport, and that probing soil erodibility with a robot has the potential to improve our understanding of this multifaceted problem.

  1. HARP targets pion production cross section and yield measurements: Implications for MiniBooNE neutrino flux

    NASA Astrophysics Data System (ADS)

    Wickremasinghe, Don Athula Abeyarathna

    The prediction of the muon neutrino flux from a 71.0 cm long beryllium target for the MiniBooNE experiment is based on a measured pion production cross section which was taken from a short beryllium target (2.0 cm thick - 5% nuclear interaction length) in the Hadron Production (HARP) experiment at CERN. To verify the extrapolation to our longer target, HARP also measured the pion production from 20.0 cm and 40.0 cm beryllium targets. The measured production yields on targets of 50% and 100% nuclear interaction lengths in the kinematic rage of momentum from 0.75 GeV/c to 6.5 GeV/c and the range of angle from 30 mrad to 210 mrad are presented along with an update of the short target cross sections. The best fitted extended Sanford-Wang (SW) model parameterization for updated short beryllium target positive pion production cross section is presented. Yield measurements for all three targets are also compared with that from the Monte Carlo predictions in the MiniBooNE experiment for different SW parameterization. The comparisons of muon neutrino flux predictions for updated SW model is presented.

  2. Forearm Torque and Lifting Strength: Normative Data.

    PubMed

    Axelsson, Peter; Fredrikson, Per; Nilsson, Anders; Andersson, Jonny K; Kärrholm, Johan

    2018-02-10

    To establish reference values for new methods designed to quantitatively measure forearm torque and lifting strength and to compare these values with grip strength. A total of 499 volunteers, 262 males and 237 females, aged 15 to 85 (mean, 44) years, were tested for lifting strength and forearm torque with the Kern and Baseline dynamometers. These individuals were also tested for grip strength with a Jamar dynamometer. Standardized procedures were used and information about sex, height, weight, hand dominance, and whether their work involved high or low manual strain was collected. Men had approximately 70% higher forearm torque and lifting strength compared with females. Male subjects aged 26 to 35 years and female subjects aged 36 to 45 years showed highest strength values. In patients with dominant right side, 61% to 78% had a higher or equal strength on this side in the different tests performed. In patients with dominant left side, the corresponding proportions varied between 41% and 65%. There was a high correlation between grip strength and forearm torque and lifting strength. Sex, body height, body weight, and age showed a significant correlation to the strength measurements. In a multiple regression model sex, age (entered as linear and squared) could explain 51% to 63% of the total variances of forearm torque strength and 30% to 36% of lifting strength. Reference values for lifting strength and forearm torque to be used in clinical practice were acquired. Grip strength has a high correlation to forearm torque and lifting strength. Sex, age, and height can be used to predict forearm torque and lifting strength. Prediction equations using these variables were generated. Normative data of forearm torque and lifting strength might improve the quality of assessment of wrist and forearm disorders as well as their treatments. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  3. Validity and reliability of an instrumented leg-extension machine for measuring isometric muscle strength of the knee extensors.

    PubMed

    Ruschel, Caroline; Haupenthal, Alessandro; Jacomel, Gabriel Fernandes; Fontana, Heiliane de Brito; Santos, Daniela Pacheco dos; Scoz, Robson Dias; Roesler, Helio

    2015-05-20

    Isometric muscle strength of knee extensors has been assessed for estimating performance, evaluating progress during physical training, and investigating the relationship between isometric and dynamic/functional performance. To assess the validity and reliability of an adapted leg-extension machine for measuring isometric knee extensor force. Validity (concurrent approach) and reliability (test and test-retest approach) study. University laboratory. 70 healthy men and women aged between 20 and 30 y (39 in the validity study and 31 in the reliability study). Intraclass correlation coefficient (ICC) values calculated for the maximum voluntary isometric torque of knee extensors at 30°, 60°, and 90°, measured with the prototype and with an isokinetic dynamometer (ICC2,1, validity study) and measured with the prototype in test and retest sessions, scheduled from 48 h to 72 h apart (ICC1,1, reliability study). In the validity analysis, the prototype showed good agreement for measurements at 30° (ICC2,1 = .75, SEM = 18.2 Nm) and excellent agreement for measurements at 60° (ICC2,1 = .93, SEM = 9.6 Nm) and at 90° (ICC2,1 = .94, SEM = 8.9 Nm). Regarding the reliability analysis, between-days' ICC1,1 were good to excellent, ranging from .88 to .93. Standard error of measurement and minimal detectable difference based on test-retest ranged from 11.7 Nm to 18.1 Nm and 32.5 Nm to 50.1 Nm, respectively, for the 3 analyzed knee angles. The analysis of validity and repeatability of the prototype for measuring isometric muscle strength has shown to be good or excellent, depending on the knee joint angle analyzed. The new instrument, which presents a relative low cost and easiness of transportation when compared with an isokinetic dynamometer, is valid and provides consistent data concerning isometric strength of knee extensors and, for this reason, can be used for practical, clinical, and research purposes.

  4. Tracking Emotional and Behavioral Changes in Childhood: Does the Strength and Difficulties Questionnaire Measure the Same Constructs across Time?

    ERIC Educational Resources Information Center

    Sosu, Edward M.; Schmidt, Peter

    2017-01-01

    R. Goodman's Strength and Difficulties Questionnaire (SDQ) is widely used to measure emotional and behavioral difficulties in childhood and adolescence. In the present study, we examined whether the SDQ measures the same construct across time, when used for longitudinal research. A nationally representative sample of parents (N = 3,375) provided…

  5. Target reflectance measurements for calibration of lidar atmospheric backscatter data

    NASA Technical Reports Server (NTRS)

    Kavaya, M. J.; Menzies, R. T.; Haner, D. A.; Oppenheim, U. P.; Flamant, P. H.

    1983-01-01

    Wavelength and angular dependence of reflectances and depolarization in the 9-11 micron region are reported for four standard targets: flowers of sulfur, flame-sprayed aluminum, 20-grit sandblasted aluminum, and 400-grit silicon carbon sandpaper. Measurements are presented and compared using a CW CO2 grating-tunable laser in a laboratory backscatter apparatus, an integrating sphere, and a coherent pulsed TEA-CO2 lidar system operating in the 9-11 micron region. Reflectance theory related to the use of hard targets to calibrate lidar atmospheric backscatter data is discussed.

  6. State-of-the-Art pH Electrode Quality Control for Measurements of Acidic, Low Ionic Strength Waters.

    ERIC Educational Resources Information Center

    Stapanian, Martin A.; Metcalf, Richard C.

    1990-01-01

    Described is the derivation of the relationship between the pH measurement error and the resulting percentage error in hydrogen ion concentration including the use of variable activity coefficients. The relative influence of the ionic strength of the solution on the percentage error is shown. (CW)

  7. External Heat Transfer Coefficient Measurements on a Surrogate Indirect Inertial Confinement Fusion Target

    DOE PAGES

    Miles, Robin; Havstad, Mark; LeBlanc, Mary; ...

    2015-09-15

    External heat transfer coefficients were measured around a surrogate Indirect inertial confinement fusion (ICF) based on the Laser Inertial Fusion Energy (LIFE) design target to validate thermal models of the LIFE target during flight through a fusion chamber. Results indicate that heat transfer coefficients for this target 25-50 W/m 2∙K are consistent with theoretically derived heat transfer coefficients and valid for use in calculation of target heating during flight through a fusion chamber.

  8. Semantic priming increases word frequency judgments: Evidence for the role of memory strength in frequency estimation.

    PubMed

    Woltz, Dan J; Gardner, Michael K

    2015-09-01

    Previous research has demonstrated a systematic, nonlinear relationship between word frequency judgments and values from word frequency norms. This relationship could reflect a perceptual process similar to that found in the psychophysics literature for a variety of sensory phenomena. Alternatively, it could reflect memory strength differences that are expected for words of varying levels of prior exposure. Two experiments tested the memory strength explanation by semantically priming words prior to frequency judgments. Exposure to related word meanings produced a small but measurable increase in target word frequency ratings. Repetition but not semantic priming had a greater impact on low compared to high frequency words. These findings are consistent with a memory strength view of frequency judgments that assumes a distributed network with lexical and semantic levels of representation. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Burrowing as a novel voluntary strength training method for mice: A comparison of various voluntary strength or resistance exercise methods.

    PubMed

    Roemers, P; Mazzola, P N; De Deyn, P P; Bossers, W J; van Heuvelen, M J G; van der Zee, E A

    2018-04-15

    Voluntary strength training methods for rodents are necessary to investigate the effects of strength training on cognition and the brain. However, few voluntary methods are available. The current study tested functional and muscular effects of two novel voluntary strength training methods, burrowing (digging a substrate out of a tube) and unloaded tower climbing, in male C57Bl6 mice. To compare these two novel methods with existing exercise methods, resistance running and (non-resistance) running were included. Motor coordination, grip strength and muscle fatigue were measured at baseline, halfway through and near the end of a fourteen week exercise intervention. Endurance was measured by an incremental treadmill test after twelve weeks. Both burrowing and resistance running improved forelimb grip strength as compared to controls. Running and resistance running increased endurance in the treadmill test and improved motor skills as measured by the balance beam test. Post-mortem tissue analyses revealed that running and resistance running induced Soleus muscle hypertrophy and reduced epididymal fat mass. Tower climbing elicited no functional or muscular changes. As a voluntary strength exercise method, burrowing avoids the confounding effects of stress and positive reinforcers elicited in forced strength exercise methods. Compared to voluntary resistance running, burrowing likely reduces the contribution of aerobic exercise components. Burrowing qualifies as a suitable voluntary strength training method in mice. Furthermore, resistance running shares features of strength training and endurance (aerobic) exercise and should be considered a multi-modal aerobic-strength exercise method in mice. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. NMR measurements on the triumf polarized deuterium target

    NASA Astrophysics Data System (ADS)

    Wait, G. D.; Delheij, P. P. J.; Healey, D. C.

    1989-01-01

    The NMR system and the polarization measurements of the TRIUMF polarized deuterium target are described. The NMR tuned circuit is kept resonant at all frequencies to allow for a high gain in the rf amplifiers and to permit the measurement of the real part of the NMR signal. A Starburst (J-11) and an LSI-11 are used to process the NMR signal at a high sample rate. A synthesizer under the control of an 8085 based microprocessor (TRIMAC) provides the rf sweep. Vector polarizations between -0.33 and -0.40 were routinely achieved during a four week run in the TRIUMF M11 pion beamline with a statistical uncertainty of 3.4% and a systematic uncertainty of 5%.

  11. A Systematic Review of Isometric Lingual Strength-Training Programs in Adults With and Without Dysphagia

    PubMed Central

    Zhang, Bin; Haines, Morgan B.; Kelchner, Lisa N.

    2017-01-01

    Purpose This systematic review summarizes the effects of isometric lingual strength training on lingual strength and swallow function in adult populations. Furthermore, it evaluates the designs of the reviewed studies and identifies areas of future research in isometric lingual strength training for dysphagia remediation. Method A comprehensive literature search of 3 databases and additional backward citation search identified 10 studies for inclusion in the review. The review reports and discusses the isometric-exercise intervention protocols, pre- and postintervention lingual-pressure data (maximum peak pressures and lingual-palatal pressures during swallowing), and oropharyngeal swallowing measures such as penetration-aspiration scales, oropharyngeal residue and duration, lingual volumes, and quality-of-life assessments. Results Studies reported gains in maximum peak lingual pressures following isometric lingual strength training for both healthy adults and select groups of individuals with dysphagia. However, due to the variability in study designs, it remains unclear whether strength gains generalize to swallow function. Conclusion Although isometric lingual strength training is a promising intervention for oropharyngeal dysphagia, the current literature is too variable to confidently report specific therapeutic benefits. Future investigations should target homogenous patient populations and use randomized controlled trials to determine the efficacy of this treatment for individuals with dysphagia. PMID:28282484

  12. Measurement of the target current by inductive probe during laser interaction on terawatt laser system PALS.

    PubMed

    Cikhardt, J; Krása, J; De Marco, M; Pfeifer, M; Velyhan, A; Krouský, E; Cikhardtová, B; Klír, D; Rezáč, K; Ullschmied, J; Skála, J; Kubeš, P; Kravárik, J

    2014-10-01

    Measurements of the return-current flowing through a solid target irradiated with the sub-nanosecond kJ-class Prague Asterix Laser System is reported. A new inductive target probe was developed which allows us measuring the target current derivative in a kA/ns range. The dependences of the target current on the laser pulse energy for cooper, graphite, and polyethylene targets are reported. The experiment shows that the target current is proportional to the deposited laser energy and is strongly affected by the shot-to-shot fluctuations. The corresponding maximum target charge exceeded a value of 10 μC. A return-current dependence of the electromagnetic pulse produced by the laser-target interaction is presented.

  13. Leishmania amazonensis chemotaxis under glucose gradient studied by the strength and directionality of forces measured with optical tweezers

    NASA Astrophysics Data System (ADS)

    de Ysasa Pozzo, Liliana; Fontes, Adriana; de Thomaz, André A.; Barbosa, Luiz Carlos; Ayres, Diana Copi; Giorgio, Selma; Cesar, Carlos Lenz

    2007-02-01

    Chemotaxis is the mechanism microorganisms use to sense the environment surrounding them and to direct their movement towards attractive, or away from the repellent, chemicals. The biochemical sensing is almost the only way for communication between unicellular organisms. Prokaryote and Eukaryote chemotaxis has been mechanically studied mainly by observing the directionality and timing of the microorganisms movements subjected to a chemical gradient, but not through the directionality and strength of the forces it generates. To observe the vector force of microorganisms under a chemical gradient we developed a system composed of two large chambers connected by a tiny duct capable to keep the chemical gradient constant for more than ten hours. We also used the displacements of a microsphere trapped in an Optical Tweezers as the force transducer to measure the direction and the strength of the propulsion forces of flagellum of the microorganism under several gradient conditions. A 9μm diameter microsphere particle was trapped with a Nd:YAG laser and its movement was measured through the light scattered focused on a quadrant detector. We observed the behavior of the protozoa Leishmania amazonensis (eukaryote) under several glucose gradients. This protozoa senses the gradient around it by swimming in circles for three to five times following by tumbling, and not by the typical straight swimming/tumbling of bacteria. Our results also suggest that force direction and strength are also used to control its movement, not only the timing of swimming/tumbling, because we observed a higher force strength clearly directed towards the glucose gradient.

  14. Measuring target detection performance in paradigms with high event rates.

    PubMed

    Bendixen, Alexandra; Andersen, Søren K

    2013-05-01

    Combining behavioral and neurophysiological measurements inevitably implies mutual constraints, such as when the neurophysiological measurement requires fast-paced stimulus presentation and hence the attribution of a behavioral response to a particular preceding stimulus becomes ambiguous. We develop and test a method for validly assessing behavioral detection performance in spite of this ambiguity. We examine four approaches taken in the literature to treat such situations. We analytically derive a new variant of computing the classical parameters of signal detection theory, hit and false alarm rates, adapted to fast-paced paradigms. Each of the previous approaches shows specific shortcomings (susceptibility towards response window choice, biased estimates of behavioral detection performance). Superior performance of our new approach is demonstrated for both simulated and empirical behavioral data. Further evidence is provided by reliable correspondence between behavioral performance and the N2b component as an electrophysiological indicator of target detection. The appropriateness of our approach is substantiated by both theoretical and empirical arguments. We demonstrate an easy-to-implement solution for measuring target detection performance independent of the rate of event presentation. Thus overcoming the measurement bias of previous approaches, our method will help to clarify the behavioral relevance of different measures of cortical activation. Copyright © 2012 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  15. A comparison of the effects of 6 weeks of traditional resistance training, plyometric training, and complex training on measures of strength and anthropometrics.

    PubMed

    MacDonald, Christopher J; Lamont, Hugh S; Garner, John C

    2012-02-01

    Complex training (CT; alternating between heavy and lighter load resistance exercises with similar movement patterns within an exercise session) is a form of training that may potentially bring about a state of postactivation potentiation, resulting in increased dynamic power (Pmax) and rate of force development during the lighter load exercise. Such a method may be more effective than either modality, independently for developing strength. The purpose of this research was to compare the effects of resistance training (RT), plyometric training (PT), and CT on lower body strength and anthropometrics. Thirty recreationally trained college-aged men were trained using 1 of 3 methods: resistance, plyometric, or complex twice weekly for 6 weeks. The participants were tested pre, mid, and post to assess back squat strength, Romanian dead lift (RDL) strength, standing calf raise (SCR) strength, quadriceps girth, triceps surae girth, body mass, and body fat percentage. Diet was not controlled during this study. Statistical measures revealed a significant increase for squat strength (p = 0.000), RDL strength (p = 0.000), and SCR strength (p = 0.000) for all groups pre to post, with no differences between groups. There was also a main effect for time for girth measures of the quadriceps muscle group (p = 0.001), the triceps surae muscle group (p = 0.001), and body mass (p = 0.001; post hoc revealed no significant difference). There were main effects for time and group × time interactions for fat-free mass % (RT: p = 0.031; PT: p = 0.000). The results suggest that CT mirrors benefits seen with traditional RT or PT. Moreover, CT revealed no decrement in strength and anthropometric values and appears to be a viable training modality.

  16. Modeling strength data for CREW CHIEF

    NASA Technical Reports Server (NTRS)

    Mcdaniel, Joe W.

    1990-01-01

    The Air Force has developed CREW CHIEF, a computer-aided design (CAD) tool for simulating and evaluating aircraft maintenance to determine if the required activities are feasible. CREW CHIEF gives the designer the ability to simulate maintenance activities with respect to reach, accessibility, strength, hand tool operation, and materials handling. While developing the CREW CHIEF, extensive research was performed to describe workers strength capabilities for using hand tools and manual handling of objects. More than 100,000 strength measures were collected and modeled for CREW CHIEF. These measures involved both male and female subjects in the 12 maintenance postures included in CREW CHIEF. The data collection and modeling effort are described.

  17. Study on the measurement system of the target polarization characteristics and test

    NASA Astrophysics Data System (ADS)

    Fu, Qiang; Zhu, Yong; Zhang, Su; Duan, Jin; Yang, Di; Zhan, Juntong; Wang, Xiaoman; Jiang, Hui-Lin

    2015-10-01

    The polarization imaging detection technology increased the polarization information on the basis of the intensity imaging, which is extensive application in the military and civil and other fields, the research on the polarization characteristics of target is particularly important. The research of the polarization reflection model was introduced in this paper, which describes the scattering vector light energy distribution in reflecting hemisphere polarization characteristics, the target polarization characteristics test system solutions was put forward, by the irradiation light source, measuring turntable and camera, etc, which illuminate light source shall direct light source, with laser light sources and xenon lamp light source, light source can be replaced according to the test need; Hemispherical structure is used in measuring circumarotate placed near its base material sample, equipped with azimuth and pitching rotation mechanism, the manual in order to adjust the azimuth Angle and high Angle observation; Measuring camera pump works, through the different in the way of motor control polaroid polarization test, to ensure the accuracy of measurement and imaging resolution. The test platform has set up by existing laboratory equipment, the laser is 532 nm, line polaroid camera, at the same time also set the sending and receiving optical system. According to the different materials such as wood, metal, plastic, azimuth Angle and zenith Angle in different observation conditions, measurement of target in the polarization scattering properties of different exposure conditions, implementation of hemisphere space pBRDF measurement.

  18. Strength and power predictors of sports speed.

    PubMed

    Cronin, John B; Hansen, Keir T

    2005-05-01

    For many sporting activities, initial speed rather than maximal speed would be considered of greater importance to successful performance. The purpose of this study was to identify the relationship between strength and power and measures of first-step quickness (5-m time), acceleration (10-m time), and maximal speed (30-m time). The maximal strength (3 repetition maximum [3RM]), power (30-kg jump squat, countermovement, and drop jumps), isokinetic strength measures (hamstring and quadriceps peak torques and ratios at 60 degrees .s(-1) and 300 degrees .s(-1)) and 5-m, 10-m, and 30-m sprint times of 26 part-time and full-time professional rugby league players (age 23.2 +/- 3.3 years) were measured. To examine the importance of the strength and power measures on sprint performance, a correlational approach and a comparison between means of the fastest and slowest players was used. The correlations between the 3RM, drop jump, isokinetic strength measures, and the 3 measures of sport speed were nonsignificant. Correlations between the jump squat (height and relative power output) and countermovement jump height and the 3 speed measures were significant (r = -0.43 to -0.66, p < 0.05). The squat and countermovement jump heights as well as squat jump relative power output were the only variables found to be significantly greater in the fast players. It was suggested that improving the power to weight ratio as well as plyometric training involving countermovement and loaded jump-squat training may be more effective for enhancing sport speed in elite players.

  19. Measure of microhardness, fracture toughness and flexural strength of N-vinylcaprolactam (NVC)-containing glass-ionomer dental cements.

    PubMed

    Moshaverinia, Alireza; Brantley, William A; Chee, Winston W L; Rohpour, Nima; Ansari, Sahar; Zheng, Fengyuan; Heshmati, Reza H; Darr, Jawwad A; Schricker, Scott R; Rehman, Ihtesham U

    2010-12-01

    To investigate the effects of N-vinylcaprolactam (NVC)-containing terpolymers on the fracture toughness, microhardness, and flexural strength of conventional glass-ionomer cements (GIC). The terpolymer of acrylic acid (AA)-itaconic acid (IA)-N-vinylcaprolactam (NVC) with 8:1:1 (AA:IA:NVC) molar ratio was synthesized by free radical polymerization and characterized using (1)H NMR and FTIR. Experimental GIC samples were made from a 50% solution of the synthesized terpolymer with Fuji IX powder in a 3.6:1 P/L ratio. Specimens were mixed and fabricated at room temperature. Plane strain fracture toughness (K(Ic)) was measured in accordance with ASTM Standard 399-05. Vickers hardness was determined using a microhardness tester. Flexural strength was measured using samples with dimensions of 2 mm×2 mm×20 mm. For all mechanical property tests, specimens were first conditioned in distilled water at 37°C for 1 day or 1 week. Fracture toughness and flexural strength tests were conducted on a screw-driven universal testing machine using a crosshead speed of 0.5mm/min. Values of mechanical properties for the experimental GIC were compared with the control group (Fuji IX GIC), using one-way ANOVA and the Tukey multiple range test at α=0.05. The NVC-modified GIC exhibited significantly higher fracture toughness compared to the commercially available Fuji IX GIC, along with higher mean values of flexural strength and Vickers hardness, which were not significantly different. It was concluded that NVC-containing polymers are capable of enhancing clinically relevant properties for GICs. This new modified glass-ionomer is a promising restorative dental material. Copyright © 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  20. HARP targets pion production cross section and yield measurements. Implications for MiniBooNE neutrino flux

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wickremasinghe, Don Athula Abeyarathna

    2015-07-01

    The prediction of the muon neutrino flux from a 71.0 cm long beryllium target for the MiniBooNE experiment is based on a measured pion production cross section which was taken from a short beryllium target (2.0 cm thick - 5% nuclear interaction length) in the Hadron Production (HARP) experiment at CERN. To verify the extrapolation to our longer target, HARP also measured the pion production from 20.0 cm and 40.0 cm beryllium targets. The measured production yields, d 2N π± (p; θ )=dpd Ω, on targets of 50% and 100% nuclear interaction lengths in the kinematic rage of momentum frommore » 0.75 GeV/c to 6.5 GeV/c and the range of angle from 30 mrad to 210 mrad are presented along with an update of the short target cross sections. The best fitted extended Sanford-Wang (SW) model parameterization for updated short beryllium target π + production cross section is presented. Yield measurements for all three targets are also compared with that from the Monte Carlo predictions in the MiniBooNE experiment for different SW parameterization. The comparisons of v μ flux predictions for updated SW model is presented.« less

  1. The concept of collision strength and its applications

    NASA Astrophysics Data System (ADS)

    Chang, Yongbin

    Collision strength, the measure of strength for a binary collision, hasn't been defined clearly. In practice, many physical arguments have been employed for the purpose and taken for granted. A scattering angle has been widely and intensively used as a measure of collision strength in plasma physics for years. The result of this is complication and unnecessary approximation in deriving some of the basic kinetic equations and in calculating some of the basic physical terms. The Boltzmann equation has a five-fold integral collision term that is complicated. Chandrasekhar and Spitzer's approaches to the linear Fokker-Planck coefficients have several approximations. An effective variable-change technique has been developed in this dissertation as an alternative to scattering angle as the measure of collision strength. By introducing the square of the reduced impulse or its equivalencies as a collision strength variable, many plasma calculations have been simplified. The five-fold linear Boltzmann collision integral and linearized Boltzmann collision integral are simplified to three-fold integrals. The arbitrary order linear Fokker-Planck coefficients are calculated and expressed in a uniform expression. The new theory provides a simple and exact method for describing the equilibrium plasma collision rate, and a precise calculation of the equilibrium relaxation time. It generalizes bimolecular collision reaction rate theory to a reaction rate theory for plasmas. A simple formula of high precision with wide temperature range has been developed for electron impact ionization rates for carbon atoms and ions. The universality of the concept of collision strength is emphasized. This dissertation will show how Arrhenius' chemical reaction rate theory and Thomson's ionization theory can be unified as one single theory under the concept of collision strength, and how many important physical terms in different disciplines, such as activation energy in chemical reaction theory

  2. Fast-timing lifetime measurement of 152Gd

    NASA Astrophysics Data System (ADS)

    Wiederhold, J.; Kern, R.; Lizarazo, C.; Pietralla, N.; Werner, V.; Jolos, R. V.; Bucurescu, D.; Florea, N.; Ghita, D.; Glodariu, T.; Lica, R.; Marginean, N.; Marginean, R.; Mihai, C.; Mihai, R.; Mitu, I. O.; Negret, A.; Nita, C.; Olacel, A.; Pascu, S.; Stroe, L.; Toma, S.; Turturica, A.

    2016-10-01

    The lifetime τ (02+) of 152Gd has been measured using fast electronic scintillation timing (FEST) with an array of high-purity germanium (HPGe) and cerium-doped lanthanum bromide (LaBr3) detectors. 152Gd was produced via an (α ,n ) reaction on a gold backed 149Sm target. The measured lifetime of τ (02+) =96 (6 ) ps corresponds to a reduced transition strength of B (E 2 ;02+→21+) =111 (7 ) W.u. and an E 0 transition strength of ρ2(E 0 ) =39 (3 ) ×10-3 to the ground state. This result provides experimental support for the validity of a correlation that would be a novel indicator for a quantum phase transition (QPT).

  3. Precise measurement of coupling strength and high temperature quantum effect in a nonlinearly coupled qubit-oscillator system

    NASA Astrophysics Data System (ADS)

    Ge, Li; Zhao, Nan

    2018-04-01

    We study the coherence dynamics of a qubit coupled to a harmonic oscillator with both linear and quadratic interactions. As long as the linear coupling strength is much smaller than the oscillator frequency, the long time behavior of the coherence is dominated by the quadratic coupling strength g 2. The coherence decays and revives at a period , with the width of coherence peak decreasing as the temperature increases, hence providing a way to measure g 2 precisely without cooling. Unlike the case of linear coupling, here the coherence dynamics never reduces to the classical limit in which the oscillator is classical. Finally, the validity of linear coupling approximation is discussed and the coherence under Hahn-echo is evaluated.

  4. Notch strength of composites

    NASA Technical Reports Server (NTRS)

    Whitney, J. M.

    1983-01-01

    The notch strength of composites is discussed. The point stress and average stress criteria relate the notched strength of a laminate to the average strength of a relatively long tensile coupon. Tests of notched specimens in which microstrain gages have been placed at or near the edges of the holes have measured strains much larger that those measured in an unnotched tensile coupon. Orthotropic stress concentration analyses of failed notched laminates have also indicated that failure occurred at strains much larger than those experienced on tensile coupons with normal gage lengths. This suggests that the high strains at the edge of a hole can be related to the very short length of fiber subjected to these strains. Lockheed has attempted to correlate a series of tests of several laminates with holes ranging from 0.19 to 0.50 in. Although the average stress criterion correlated well with test results for hole sizes equal to or greater than 0.50 in., it over-estimated the laminate strength in the range of hole sizes from 0.19 to 0.38 in. It thus appears that a theory is needed that is based on the mechanics of failure and is more generally applicable to the range of hole sizes and the varieties of laminates found in aircraft construction.

  5. Clinical assessment of hand strength using a microcomputer.

    PubMed

    Jain, A S; Hennedy, J A; Carus, D A

    1985-10-01

    A microcomputer based system has been designed for precise, objective quantification of hand strength. Pinch, grasp and shear strengths are measured using force transducers. The system, which is quick and easy to operate, not only measures these strengths accurately, but also collects, stores and displays this data numerically or in graphical form, at the touch of a button. The data can be manipulated to answer any type of statistical question related to any group of patients. The assessment of hand strength in ninety-six people, representing normal hand function, by means of this system, is reported.

  6. Exploding Pusher Targets for Electron-Ion Coupling Measurements

    NASA Astrophysics Data System (ADS)

    Whitley, Heather D.; Pino, Jesse; Schneider, Marilyn; Shepherd, Ronnie; Benedict, Lorin; Bauer, Joseph; Graziani, Frank; Garbett, Warren

    2015-11-01

    Over the past several years, we have conducted theoretical investigations of electron-ion coupling and electronic transport in plasmas. In the regime of weakly coupled plasmas, we have identified models that we believe describe the physics well, but experimental data is still needed to validate the models. We are currently designing spectroscopic experiments to study electron-ion equilibration and/or electron heat transport using exploding pusher (XP) targets for experiments at the National Ignition Facility. Two platforms are being investigated: an indirect drive XP (IDXP) with a plastic ablator and a polar-direct drive XP (PDXP) with a glass ablator. The fill gas for both designs is D2. We propose to use a higher-Z dopant, such as Ar, as a spectroscopic tracer for time-resolved electron and ion temperature measurements. We perform 1D simulations using the ARES hydrodynamic code, in order to produce the time-resolved plasma conditions, which are then post-processed with CRETIN to assess the feasibility of a spectroscopic measurement. We examine target performance with respect to variations in gas fill pressure, ablator thickness, atom fraction of the Ar dopant, and drive energy, and assess the sensitivity of the predicted spectra to variations in the models for electron-ion equilibration and thermal conductivity. Prepared by LLNL under Contract DE-AC52-07NA27344. LLNL-ABS-675219.

  7. Functional strength of commercial-airline stewardesses.

    DOT National Transportation Integrated Search

    1975-11-01

    Data from 13 body measurements and 4 strength tests on 152 female flight attendants are reported herein. The stewardesses are taller (x bar = 165.8 cm) and lighter (x bar = 54.6 kg) than the corresponding age in the civilian population. The strength ...

  8. Understanding and Measuring LGBTQ Pathways to Health: A Scoping Review of Strengths-Based Health Promotion Approaches in LGBTQ Health Research.

    PubMed

    Gahagan, Jacqueline; Colpitts, Emily

    2017-01-01

    Health research traditionally has focused on the health risks and deficits of lesbian, gay, bisexual, transgender, and queer (LGBTQ) populations, obscuring the determinants that can promote health across the life course. Recognizing, appropriately measuring, and rendering visible these determinants of health is paramount to informing appropriate and engaging health policies, services, and systems for LGBTQ populations. The overarching purpose of this article is to provide an overview of the findings of a scoping review aimed at exploring strengths-based health promotion approaches to understanding and measuring LGBTQ health. Specifically, this scoping review examined peer-reviewed, published academic literature to determine (a) existing methodological frameworks for studying LGBTQ health from a strengths-based health promotion approach, and (b) suggestions for future methodological approaches for studying LGBTQ health from a strengths-based health promotion approach. The findings of this scoping review will be used to inform the development of a study aimed at assessing the health of and improving pathways to health services among LGBTQ populations in Nova Scotia, Canada.

  9. Development of a vision-targeted health-related quality of life item measure

    PubMed Central

    Slotkin, Jerry; McKean-Cowdin, Roberta; Lee, Paul; Owsley, Cynthia; Vitale, Susan; Varma, Rohit; Gershon, Richard; Hays, Ron D.

    2013-01-01

    Purpose To develop a vision-targeted health-related quality of life (HRQOL) measure for the NIH Toolbox for the Assessment of Neurological and Behavioral Function. Methods We conducted a review of existing vision-targeted HRQOL surveys and identified color vision, low luminance vision, distance vision, general vision, near vision, ocular symptoms, psychosocial well-being, and role performance domains. Items in existing survey instruments were sorted into these domains. We selected non-redundant items and revised them to improve clarity and to limit the number of different response options. We conducted 10 cognitive interviews to evaluate the items. Finally, we revised the items and administered them to 819 individuals to calibrate the items and estimate the measure’s reliability and validity. Results The field test provided support for the 53-item vision-targeted HRQOL measure encompassing 6 domains: color vision, distance vision, near vision, ocular symptoms, psychosocial well-being, and role performance. The domain scores had high levels of reliability (coefficient alphas ranged from 0.848 to 0.940). Validity was supported by high correlations between National Eye Institute Visual Function Questionnaire scales and the new-vision-targeted scales (highest values were 0.771 between psychosocial well-being and mental health, and 0.729 between role performance and role difficulties), and by lower mean scores in those groups self-reporting eye disease (F statistic with p < 0.01 for all comparisons except cataract with ocular symptoms, psychosocial well-being, and role performance scales). Conclusions This vision-targeted HRQOL measure provides a basis for comprehensive assessment of the impact of eye diseases and treatments on daily functioning and well-being in adults. PMID:23475688

  10. Measurement of Deeply Virtual Compton Scattering with a Polarized-Proton Target

    NASA Astrophysics Data System (ADS)

    Chen, S.; Avakian, H.; Burkert, V. D.; Eugenio, P.; Adams, G.; Amarian, M.; Ambrozewicz, P.; Anghinolfi, M.; Asryan, G.; Bagdasaryan, H.; Baillie, N.; Ball, J. P.; Baltzell, N. A.; Barrow, S.; Batourine, V.; Battaglieri, M.; Beard, K.; Bedlinskiy, I.; Bektasoglu, M.; Bellis, M.; Benmouna, N.; Berman, B. L.; Biselli, A. S.; Bonner, B. E.; Bouchigny, S.; Boiarinov, S.; Bosted, P.; Bradford, R.; Branford, D.; Briscoe, W. J.; Brooks, W. K.; Bültmann, S.; Butuceanu, C.; Calarco, J. R.; Careccia, S. L.; Carman, D. S.; Carnahan, B.; Cazes, A.; Cole, P. L.; Collins, P.; Coltharp, P.; Cords, D.; Corvisiero, P.; Crabb, D.; Crannell, H.; Crede, V.; Cummings, J. P.; Masi, R. De; Devita, R.; Sanctis, E. De; Degtyarenko, P. V.; Denizli, H.; Dennis, L.; Deur, A.; Dharmawardane, K. V.; Dhuga, K. S.; Djalali, C.; Dodge, G. E.; Donnelly, J.; Doughty, D.; Dugger, M.; Dytman, S.; Dzyubak, O. P.; Egiyan, H.; Egiyan, K. S.; Fassi, L. El; Elouadrhiri, L.; Fatemi, R.; Fedotov, G.; Feldman, G.; Feuerbach, R. J.; Forest, T. A.; Funsten, H.; Garçon, M.; Gavalian, G.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Golovatch, E.; Gonenc, A.; Gothe, R. W.; Griffioen, K. A.; Guidal, M.; Guillo, M.; Guler, N.; Guo, L.; Gyurjyan, V.; Hadjidakis, C.; Hafidi, K.; Hakobyan, H.; Hakobyan, R. S.; Hardie, J.; Heddle, D.; Hersman, F. W.; Hicks, K.; Hleiqawi, I.; Holtrop, M.; Huertas, M.; Hyde-Wright, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Ito, M. M.; Jenkins, D.; Jo, H. S.; Joo, K.; Juengst, H. G.; Keith, C.; Kellie, J. D.; Khandaker, M.; Kim, K. Y.; Kim, K.; Kim, W.; Klein, A.; Klein, F. J.; Klusman, M.; Kossov, M.; Kramer, L. H.; Kubarovsky, V.; Kuhn, J.; Kuhn, S. E.; Kuleshov, S. V.; Lachniet, J.; Laget, J. M.; Langheinrich, J.; Lawrence, D.; Li, Ji; Lima, A. C. S.; Livingston, K.; Lu, H.; Lukashin, K.; MacCormick, M.; Markov, N.; McAleer, S.; McKinnon, B.; McNabb, J. W. C.; Mecking, B. A.; Mestayer, M. D.; Meyer, C. A.; Mibe, T.; Mikhailov, K.; Minehart, R.; Mirazita, M.; Miskimen, R.; Mokeev, V.; Morand, L.; Morrow, S. A.; Moteabbed, M.; Mueller, J.; Mutchler, G. S.; Nadel-Turonski, P.; Napolitano, J.; Nasseripour, R.; Natasha, N.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Niczyporuk, B. B.; Niroula, M. R.; Niyazov, R. A.; Nozar, M.; O'Rielly, G. V.; Osipenko, M.; Ostrovidov, A. I.; Park, K.; Pasyuk, E.; Paterson, C.; Philips, S. A.; Pierce, J.; Pivnyuk, N.; Pocanic, D.; Pogorelko, O.; Polli, E.; Popa, I.; Pozdniakov, S.; Preedom, B. M.; Price, J. W.; Prok, Y.; Protopopescu, D.; Qin, L. M.; Raue, B. A.; Riccardi, G.; Ricco, G.; Ripani, M.; Ritchie, B. G.; Ronchetti, F.; Rosner, G.; Rossi, P.; Rowntree, D.; Rubin, P. D.; Sabatié, F.; Salgado, C.; Santoro, J. P.; Sapunenko, V.; Schumacher, R. A.; Serov, V. S.; Sharabian, Y. G.; Shaw, J.; Shvedunov, N. V.; Skabelin, A. V.; Smith, E. S.; Smith, L. C.; Sober, D. I.; Stavinsky, A.; Stepanyan, S. S.; Stepanyan, S.; Stokes, B. E.; Stoler, P.; Strakovsky, I. I.; Strauch, S.; Suleiman, R.; Taiuti, M.; Tedeschi, D. J.; Thoma, U.; Tkabladze, A.; Tkachenko, S.; Todor, L.; Tur, C.; Ungaro, M.; Vanderhaeghen, M.; Vineyard, M. F.; Vlassov, A. V.; Watts, D. P.; Weinstein, L. B.; Weygand, D. P.; Williams, M.; Wolin, E.; Wood, M. H.; Yegneswaran, A.; Yun, J.; Zana, L.; Zhang, J.; Zhao, B.; Zhao, Z.

    2006-08-01

    The longitudinal target-spin asymmetry AUL for the exclusive electroproduction of high-energy photons was measured for the first time in ep→→e'pγ. The data have been accumulated at JLab with the CLAS spectrometer using 5.7 GeV electrons and a longitudinally polarized NH3 target. A significant azimuthal angular dependence was observed, resulting from the interference of the deeply virtual Compton scattering and Bethe-Heitler processes. The amplitude of the sin⁡ϕ moment is 0.252±0.042stat±0.020sys. Theoretical calculations are in good agreement with the magnitude and the kinematic dependence of the target-spin asymmetry, which is sensitive to the generalized parton distributions H˜ and H.

  11. Novel Use of the Nintendo Wii Board for Measuring Isometric Lower Limb Strength: A Reproducible and Valid Method in Older Adults.

    PubMed

    Gronbech Jorgensen, Martin; Andersen, Stig; Ryg, Jesper; Masud, Tahir

    2015-01-01

    Portable, low-cost, objective and reproducible assessment of muscle strength in the lower limbs is important as it allows clinicians to precisly track progression of patients undergoing rehabilitation. The Nintendo Wii Balance Board (WBB) is portable, inexpensive, durable, available worldwide, and may serve the above function. The purpose of the study was to evaluate (1) reproducibility and (2) concurrent validity of the WBB for measuring isometric muscle strength in the lower limb. A custom hardware and software was developed to utilize the WBB for assessment of isometric muscle strength. Thirty older adults (69.0 ± 4.2 years of age) were studied on two separate occasions on both the WBB and a stationary isometric dynamometer (SID). On each occasion, three recordings were obtained from each device. For the first recording, means and maximum values were used for further analysis. The test-retest reproducibility was examined using intraclass correlation coefficients (ICC), Standard Error of Measurement (SEM), and limits of agreement (LOA). Bland-Altman plots (BAP) and ICC's were used to explore concurrent validity. No systematic difference between test-retest was detected for the WBB. ICC within-device were between 0.90 and 0.96 and between-devices were from 0.80 to 0.84. SEM ranged for the WBB from 9.7 to 13.9%, and for the SID from 11.9 to 13.1%. LOA ranged for the WBB from 20.3 to 28.7% and for the SID from 24.2 to 26.6%. The BAP showed no relationship between the difference and the mean. A high relative and an acceptable absolute reproducibility combined with a good validity was found for the novel method using the WBB for measuring isometric lower limb strength in older adults. Further research using the WBB for assessing lower limb strength should be conducted in different study-populations.

  12. High-Tensile Strength Tape Versus High-Tensile Strength Suture: A Biomechanical Study.

    PubMed

    Gnandt, Ryan J; Smith, Jennifer L; Nguyen-Ta, Kim; McDonald, Lucas; LeClere, Lance E

    2016-02-01

    To determine which suture design, high-tensile strength tape or high-tensile strength suture, performed better at securing human tissue across 4 selected suture techniques commonly used in tendinous repair, by comparing the total load at failure measured during a fixed-rate longitudinal single load to failure using a biomechanical testing machine. Matched sets of tendon specimens with bony attachments were dissected from 15 human cadaveric lower extremities in a manner allowing for direct comparison testing. With the use of selected techniques (simple Mason-Allen in the patellar tendon specimens, whip stitch in the quadriceps tendon specimens, and Krackow stitch in the Achilles tendon specimens), 1 sample of each set was sutured with a 2-mm braided, nonabsorbable, high-tensile strength tape and the other with a No. 2 braided, nonabsorbable, high-tensile strength suture. A total of 120 specimens were tested. Each model was loaded to failure at a fixed longitudinal traction rate of 100 mm/min. The maximum load and failure method were recorded. In the whip stitch and the Krackow-stitch models, the high-tensile strength tape had a significantly greater mean load at failure with a difference of 181 N (P = .001) and 94 N (P = .015) respectively. No significant difference was found in the Mason-Allen and simple stitch models. Pull-through remained the most common method of failure at an overall rate of 56.7% (suture = 55%; tape = 58.3%). In biomechanical testing during a single load to failure, high-tensile strength tape performs more favorably than high-tensile strength suture, with a greater mean load to failure, in both the whip- and Krackow-stitch models. Although suture pull-through remains the most common method of failure, high-tensile strength tape requires a significantly greater load to pull-through in a whip-stitch and Krakow-stitch model. The biomechanical data obtained in the current study indicates that high-tensile strength tape may provide better repair

  13. Cluster analysis of novel isometric strength measures produces a valid and evidence-based classification structure for wheelchair track racing.

    PubMed

    Connick, Mark J; Beckman, Emma; Vanlandewijck, Yves; Malone, Laurie A; Blomqvist, Sven; Tweedy, Sean M

    2017-11-25

    The Para athletics wheelchair-racing classification system employs best practice to ensure that classes comprise athletes whose impairments cause a comparable degree of activity limitation. However, decision-making is largely subjective and scientific evidence which reduces this subjectivity is required. To evaluate whether isometric strength tests were valid for the purposes of classifying wheelchair racers and whether cluster analysis of the strength measures produced a valid classification structure. Thirty-two international level, male wheelchair racers from classes T51-54 completed six isometric strength tests evaluating elbow extensors, shoulder flexors, trunk flexors and forearm pronators and two wheelchair performance tests-Top-Speed (0-15 m) and Top-Speed (absolute). Strength tests significantly correlated with wheelchair performance were included in a cluster analysis and the validity of the resulting clusters was assessed. All six strength tests correlated with performance (r=0.54-0.88). Cluster analysis yielded four clusters with reasonable overall structure (mean silhouette coefficient=0.58) and large intercluster strength differences. Six athletes (19%) were allocated to clusters that did not align with their current class. While the mean wheelchair racing performance of the resulting clusters was unequivocally hierarchical, the mean performance of current classes was not, with no difference between current classes T53 and T54. Cluster analysis of isometric strength tests produced classes comprising athletes who experienced a similar degree of activity limitation. The strength tests reported can provide the basis for a new, more transparent, less subjective wheelchair racing classification system, pending replication of these findings in a larger, representative sample. This paper also provides guidance for development of evidence-based systems in other Para sports. © Article author(s) (or their employer(s) unless otherwise stated in the text of

  14. VHF/UHF imagery and RCS measurements of ground targets in forested terrain

    NASA Astrophysics Data System (ADS)

    Gatesman, Andrew J.; Beaudoin, Christopher J.; Giles, Robert H.; Waldman, Jerry; Nixon, William E.

    2002-08-01

    The monostatic VV and HH-polarized radar signatures of several targets and trees have been measured at foliage penetration frequencies (VHF/UHF) by using 1/35th scale models and an indoor radar range operating at X-band. An array of high-fidelity scale model ground vehicles and test objects as well as scaled ground terrain and trees have been fabricated for the study. Radar measurement accuracy has been confirmed by comparing the signature of a test object with a method of moments radar cross section prediction code. In addition to acquiring signatures of targets located on a smooth, dielectric ground plane, data have also been acquired with targets located in simulated wooded terrain that included scaled tree trunks and tree branches. In order to assure the correct backscattering behavior, all dielectric properties of live tree wood and moist soil were scaled properly to match the complex dielectric constant of the full-scale materials. The impact of the surrounding tree clutter on the VHF/UHF radar signatures of ground vehicles was accessed. Data were processed into high-resolution, polar-formatted ISAR imagery and signature comparisons are made between targets in open-field and forested scenarios.

  15. 47 CFR 90.689 - Field strength limits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Field strength limits. 90.689 Section 90.689...-824/851-869 Mhz Band § 90.689 Field strength limits. (a) For purposes of implementing §§ 90.689... or measured field strength at any location on the border of the EA-based service area for EA...

  16. 47 CFR 90.689 - Field strength limits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Field strength limits. 90.689 Section 90.689...-824/851-869 Mhz Band § 90.689 Field strength limits. (a) For purposes of implementing §§ 90.689... or measured field strength at any location on the border of the EA-based service area for EA...

  17. An Accurate Non-Cooperative Method for Measuring Textureless Spherical Target Based on Calibrated Lasers.

    PubMed

    Wang, Fei; Dong, Hang; Chen, Yanan; Zheng, Nanning

    2016-12-09

    Strong demands for accurate non-cooperative target measurement have been arising recently for the tasks of assembling and capturing. Spherical objects are one of the most common targets in these applications. However, the performance of the traditional vision-based reconstruction method was limited for practical use when handling poorly-textured targets. In this paper, we propose a novel multi-sensor fusion system for measuring and reconstructing textureless non-cooperative spherical targets. Our system consists of four simple lasers and a visual camera. This paper presents a complete framework of estimating the geometric parameters of textureless spherical targets: (1) an approach to calibrate the extrinsic parameters between a camera and simple lasers; and (2) a method to reconstruct the 3D position of the laser spots on the target surface and achieve the refined results via an optimized scheme. The experiment results show that our proposed calibration method can obtain a fine calibration result, which is comparable to the state-of-the-art LRF-based methods, and our calibrated system can estimate the geometric parameters with high accuracy in real time.

  18. An Accurate Non-Cooperative Method for Measuring Textureless Spherical Target Based on Calibrated Lasers

    PubMed Central

    Wang, Fei; Dong, Hang; Chen, Yanan; Zheng, Nanning

    2016-01-01

    Strong demands for accurate non-cooperative target measurement have been arising recently for the tasks of assembling and capturing. Spherical objects are one of the most common targets in these applications. However, the performance of the traditional vision-based reconstruction method was limited for practical use when handling poorly-textured targets. In this paper, we propose a novel multi-sensor fusion system for measuring and reconstructing textureless non-cooperative spherical targets. Our system consists of four simple lasers and a visual camera. This paper presents a complete framework of estimating the geometric parameters of textureless spherical targets: (1) an approach to calibrate the extrinsic parameters between a camera and simple lasers; and (2) a method to reconstruct the 3D position of the laser spots on the target surface and achieve the refined results via an optimized scheme. The experiment results show that our proposed calibration method can obtain a fine calibration result, which is comparable to the state-of-the-art LRF-based methods, and our calibrated system can estimate the geometric parameters with high accuracy in real time. PMID:27941705

  19. A high content, high throughput cellular thermal stability assay for measuring drug-target engagement in living cells.

    PubMed

    Massey, Andrew J

    2018-01-01

    Determining and understanding drug target engagement is critical for drug discovery. This can be challenging within living cells as selective readouts are often unavailable. Here we describe a novel method for measuring target engagement in living cells based on the principle of altered protein thermal stabilization / destabilization in response to ligand binding. This assay (HCIF-CETSA) utilizes high content, high throughput single cell immunofluorescent detection to determine target protein levels following heating of adherent cells in a 96 well plate format. We have used target engagement of Chk1 by potent small molecule inhibitors to validate the assay. Target engagement measured by this method was subsequently compared to target engagement measured by two alternative methods (autophosphorylation and CETSA). The HCIF-CETSA method appeared robust and a good correlation in target engagement measured by this method and CETSA for the selective Chk1 inhibitor V158411 was observed. However, these EC50 values were 23- and 12-fold greater than the autophosphorylation IC50. The described method is therefore a valuable advance in the CETSA method allowing the high throughput determination of target engagement in adherent cells.

  20. Torsional Shear Strength Tests for Glass-Ceramic Joined Silicon Carbide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferraris, Monica; Ventrella, Andrea; Salvo, Milena

    2014-03-17

    A torsion test on hour-glass-shaped samples with a full joined or a ring-shaped joined area was chosen in this study to measure shear strength of glass-ceramic joined silicon carbide. Shear strength of about 100 MPa was measured for full joined SiC with fracture completely inside their joined area. Attempts to obtain this shear strength with a ring-shaped joined area failed due to mixed mode fractures. However, full joined and ring-shaped steel hour-glasses joined by a glass-ceramic gave the same shear strength, thus suggesting that this test measures shear strength of joined components only when their fracture is completely inside theirmore » joined area.« less

  1. Sources of Life Strengths Appraisal Scale: A Multidimensional Approach to Assessing Older Adults' Perceived Sources of Life Strengths

    PubMed Central

    Fry, Prem S.; Debats, Dominique L.

    2014-01-01

    Both cognitive and psychosocial theories of adult development stress the fundamental role of older adults' appraisals of the diverse sources of cognitive and social-emotional strengths. This study reports the development of a new self-appraisal measure that incorporates key theoretical dimensions of internal and external sources of life strengths, as identified in the gerontological literature. Using a pilot study sample and three other independent samples to examine older adults' appraisals of their sources of life strengths which helped them in their daily functioning and to combat life challenges, adversity, and losses, a psychometric instrument having appropriate reliability and validity properties was developed. A 24-month followup of a randomly selected sample confirmed that the nine-scale appraisal measure (SLSAS) is a promising instrument for appraising older adults' sources of life strengths in dealing with stresses of daily life's functioning and also a robust measure for predicting outcomes of resilience, autonomy, and well-being for this age group. A unique strength of the appraisal instrument is its critically relevant features of brevity, simplicity of language, and ease of administration to frail older adults. Dedicated to the memory of Shanta Khurana whose assistance in the pilot work for the study was invaluable PMID:24772352

  2. Muscle hypertrophy, strength development, and serum hormones during strength training in elderly women with fibromyalgia.

    PubMed

    Valkeinen, H; Häkkinen, K; Pakarinen, A; Hannonen, P; Häkkinen, A; Airaksinen, O; Niemitukia, L; Kraemer, W J; Alén, M

    2005-01-01

    To examine the effects of strength training on maximal force, cross-sectional area (CSA), and electromyographic (EMG) activity of muscles and serum hormone concentrations in elderly females with fibromyalgia (FM). Twenty-six patients with FM were randomly assigned to a training (FMT; n = 13; mean age 60 years) or a control (FMC; n = 13; 59 years) group. FMT performed progressive strength training twice a week for 21 weeks. The measurements included maximal isometric and concentric leg extension forces, EMG activity of the vastus lateralis and medialis, CSA of the quadriceps femoris, and serum concentrations of testosterone (T), free testosterone (FT), growth hormone (GH), insulin-like growth factor-1 (IGF-1), dehydroepiandrosterone sulfate (DHEAS), and cortisol. Subjectively perceived symptoms of FM were also assessed. All patients were able to complete the training. In FMT strength training led to increases of 36% (p<0.001) and 33% (p<0.001) in maximal isometric and concentric forces, respectively. The CSA increased by 5% (p<0.001) and the EMG activity in isometric action by 47% (p<0.001) and in concentric action by 57% (p<0.001). Basal serum hormone concentrations remained unaltered during strength training. The subjective perceived symptoms showed a minor decreasing tendency (ns). No statistically significant changes occurred in any of these parameters in FMC. Progressive strength training increases strength, CSA, and voluntary activation of the trained muscles in elderly women with FM, while the measured basal serum hormone concentrations remain unaltered. Strength training benefits the overall physical fitness of the patients without adverse effects or any exacerbation of symptoms and should be included in the rehabilitation programmes of elderly patients with FM.

  3. Indirect monitoring shot-to-shot shock waves strength reproducibility during pump–probe experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pikuz, T. A., E-mail: tatiana.pikuz@eie.eng.osaka-u.ac.jp; Photon Pioneers Center, Osaka University, Suita, Osaka 565-0871 Japan; Joint Institute for High Temperatures, Russian Academy of Sciences, Moscow 125412

    We present an indirect method of estimating the strength of a shock wave, allowing on line monitoring of its reproducibility in each laser shot. This method is based on a shot-to-shot measurement of the X-ray emission from the ablated plasma by a high resolution, spatially resolved focusing spectrometer. An optical pump laser with energy of 1.0 J and pulse duration of ∼660 ps was used to irradiate solid targets or foils with various thicknesses containing Oxygen, Aluminum, Iron, and Tantalum. The high sensitivity and resolving power of the X-ray spectrometer allowed spectra to be obtained on each laser shot and tomore » control fluctuations of the spectral intensity emitted by different plasmas with an accuracy of ∼2%, implying an accuracy in the derived electron plasma temperature of 5%–10% in pump–probe high energy density science experiments. At nano- and sub-nanosecond duration of laser pulse with relatively low laser intensities and ratio Z/A ∼ 0.5, the electron temperature follows T{sub e} ∼ I{sub las}{sup 2/3}. Thus, measurements of the electron plasma temperature allow indirect estimation of the laser flux on the target and control its shot-to-shot fluctuation. Knowing the laser flux intensity and its fluctuation gives us the possibility of monitoring shot-to-shot reproducibility of shock wave strength generation with high accuracy.« less

  4. A randomized controlled trial for the effect of passive stretching on measures of hamstring extensibility, passive stiffness, strength, and stretch tolerance.

    PubMed

    Marshall, Paul W M; Cashman, Anthony; Cheema, Birinder S

    2011-11-01

    To measure hamstring extensibility, stiffness, stretch tolerance, and strength following a 4-week passive stretching program. Randomized controlled trial. Twenty-two healthy participants were randomly assigned to either a 4-week stretching program consisting of 4 hamstring and hip stretches performed 5 times per week, or a non-stretching control group. Hamstring extensibility and stiffness were measured before and after training using the instrumented straight leg raise test (iSLR). Stretch tolerance was measured as the pain intensity (visual analog scale; VAS) elicited during the maximal stretch. Hamstring strength was measured using isokinetic dynamometry at 30 and 120° s(-1). Hamstring extensibility increased by 20.9% in the intervention group following 4 weeks of training (p<0.001; d=0.86). Passive stiffness was reduced by 31% in the intervention group (p<0.05; d=-0.89). Stretch tolerance VAS scores were not different between groups at either time point, and no changes were observed following training. There were no changes in hamstring concentric strength measured at 30 and 120° s(-1). Passive stretching increases hamstring extensibility and decreases passive stiffness, with no change in stretch tolerance defined by pain intensity during the stretch. Compared to previous research, the volume of stretching was higher in this study. The volume of prescribed stretching is important for eliciting the strong clinical effect observed in this study. Copyright © 2011 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  5. Design of High Voltage Electrical Breakdown Strength measuring system at 1.8K with a G-M cryocooler

    NASA Astrophysics Data System (ADS)

    Li, Jian; Huang, Rongjin; Li, Xu; Xu, Dong; Liu, Huiming; Li, Laifeng

    2017-09-01

    Impregnating resins as electrical insulation materials for use in ITER magnets and feeder system are required to be radiation stable, good mechanical performance and high voltage electrical breakdown strength. In present ITER project, the breakdown strength need over 30 kV/mm, for future DEMO reactor, it will be greater than this value. In order to develop good property insulation materials to satisfy the requirements of future fusion reactor, high voltage breakdown strength measurement system at low temperature is necessary. In this paper, we will introduce our work on the design of this system. This measuring system has two parts: one is an electrical supply system which provides the high voltage from a high voltage power between two electrodes; the other is a cooling system which consists of a G-M cryocooler, a superfluid chamber and a heat switch. The two stage G-M cryocooler pre-cool down the system to 4K, the superfluid helium pot is used for a container to depress the helium to superfluid helium which cool down the sample to 1.8K and a mechanical heat switch connect or disconnect the cryocooler and the pot. In order to provide the sufficient time for the test, the cooling system is designed to keep the sample at 1.8K for 300 seconds.

  6. Measuring Multi-Megavolt Diode Voltages

    NASA Astrophysics Data System (ADS)

    Pereira, N. R.; Swanekamp, S. B.; Weber, B. V.; Commisso, R. J.; Hinshelwood, D. D.; Stephanakis, S. J.

    2002-12-01

    The voltage in high-power diodes can be determined by measuring the Compton electrons generated by the diode's bremsstrahlung radiation. This technique is implemented with a Compton-Hall (C-H) voltmeter that collimates the bremsstrahlung onto a Compton target and bends the emitted Compton electron orbits off to the side with an applied magnetic field off to Si pin diode detectors. Voltage is determined from the ratio of the Compton electron dose to the forward x-ray dose. The instrument's calibration and response are determined from coupled electron/photon transport calculations. The applicable voltage range is tuned by adjusting the position of the electron detector relative to the Compton target or by varying the magnetic field strength. The instrument was used to obtain time-dependent voltage measurements for a pinched-beam diode whose voltage is enhanced by an upstream opening switch. In this case, plasmas and vacuum electron flow from the opening switch make it difficult to determine the voltage accurately from electrical measurements. The C-H voltmeter gives voltages that are significantly higher than those obtained from electrical measurements but are consistent with measurements of peak voltage based on nuclear activation of boron-nitride targets.

  7. Differential Optical Absorption Spectroscopy (DOAS) using Targets: SO2 and NO2 Measurements in Montevideo City

    NASA Astrophysics Data System (ADS)

    Louban, Ilia; Píriz, Gustavo; Platt, Ulrich; Frins, Erna

    2008-04-01

    SO2 and NO2 were remotely measured in a main street of Montevideo city using Multiaxis-Differential Optical Absorption Spectroscopy (MAX-DOAS) combined with on-field selected targets. Target-based measurements are the basis of a new experimental procedure called Topographic Target Light scattering-DOAS (TOTAL-DOAS) that provides a well define absorption path to measure the near surface distribution of trace gases in the boundary layer. It combines the measurement principles of the long-path DOAS and zenith-scattered sunlight DOAS, within the near UV and VIS spectral range. We give a general description of the procedure and present first results of the 2006 campaign at Montevideo.

  8. The Active Target Time Projection Chamber at NSCL

    NASA Astrophysics Data System (ADS)

    Bazin, D.; Bradt, J.; Ayyad, Y.; Mittig, W.; Ahn, T.; Beceiro-Novo, S.; Carpenter, L.; Cortesi, M.; Fritsch, A.; Kolata, J. J.; Lynch, W.; Watwood, N.

    2017-11-01

    Reactions in inverse kinematics close to the Coulomb barrier offer unique opportunities to study exotic nuclei, but they are plagued by the difficulty to efficiently and precisely measure the characteristics of the emerging particles. The Active Target Time Projection Chamber (AT-TPC) offers an elegant solution to this dilemma. In this device, the detector gas of the time projection chamber is at the same time the target in which nuclear reactions take place. The use of this new paradigm offers several advantages over conventional inert target methods, the most significant being the ability to increase the luminosity of experiments without loss of resolution. The AT-TPC and some results obtained on resonant α scattering to explore the clustering properties of neutron-rich nuclei are presented, as well as fusion cross section results using a 10Be radioactive beam. In addition, the first re-accelerated radioactive beam experiment using the fully commissioned ReA3 linac was conducted recently at the NSCL with the AT-TPC, where proton resonant scattering of a 4.6 MeV/u 46Ar beam was used to measure the neutron single-particle strength in 47Ar.

  9. Normative values of isometric elbow strength in healthy adults: a systematic review.

    PubMed

    Kotte, Shamala H P; Viveen, Jetske; Koenraadt, Koen L M; The, Bertram; Eygendaal, Denise

    2018-07-01

    Post-traumatic deformities such as biceps tendon rupture or (peri-)articular fractures of the elbow are often related to a decrease in muscle strength. Postoperative evaluation of these deformities requires normative values of elbow strength. The purpose of this systematic review was to determine these normative values of isometric elbow strength in healthy adults resulting from studies evaluating this strength (i.e. flexion, extension, pronation and supination strength). The databases of PubMed, EMBASE and Web of Sciences were searched and screened for studies involving the isometric elbow strength as measured in asymptomatic volunteers. The quality of the studies was assessed and studies of low quality were excluded. Nineteen studies met the inclusion criteria and were of sufficiently high quality to be included in the present review. In these studies, elbow strength was measured in a total of 1880 healthy volunteers. The experimental set-up and devices used to measure elbow strength varied between studies. Using some assumptions, a normative values table was assembled. Large standard deviations of normative values in combination with different measurement devices used, as well as the different measurement positions of the subjects, demonstrated that there is no consensus about measuring the isometric elbow strength and therefore the normative values have to be interpreted with caution.

  10. The responsiveness of sensibility and strength tests in patients undergoing carpal tunnel decompression

    PubMed Central

    2011-01-01

    Background Several clinical measures of sensory and motor function are used alongside patient-rated questionnaires to assess outcomes of carpal tunnel decompression. However there is a lack of evidence regarding which clinical tests are most responsive to clinically important change over time. Methods In a prospective cohort study 63 patients undergoing carpal tunnel decompression were assessed using standardised clinician-derived and patient reported outcomes before surgery, at 4 and 8 months follow up. Clinical sensory assessments included: touch threshold with monofilaments (WEST), shape-texture identification (STI™ test), static two-point discrimination (Mackinnon-Dellon Disk-Criminator) and the locognosia test. Motor assessments included: grip and tripod pinch strength using a digital grip analyser (MIE), manual muscle testing of abductor pollicis brevis and opponens pollicis using the Rotterdam Intrinsic Handheld Myometer (RIHM). The Boston Carpal Tunnel Questionnaire (BCTQ) was used as a patient rated outcome measure. Results Relative responsiveness at 4 months was highest for the BCTQ symptom severity scale with moderate to large effects sizes (ES = -1.43) followed by the BCTQ function scale (ES = -0.71). The WEST and STI™ were the most responsive sensory tests at 4 months showing moderate effect sizes (WEST ES = 0.55, STI ES = 0.52). Grip and pinch strength had a relatively higher responsiveness compared to thenar muscle strength but effect sizes for all motor tests were very small (ES ≤0.10) or negative indicating a decline compared to baseline in some patients. Conclusions For clinical assessment of sensibility touch threshold assessed by monofilaments (WEST) and tactile gnosis measured with the STI™ test are the most responsive tests and are recommended for future studies. The use of handheld myometry (RIHM) for manual muscle testing, despite more specifically targeting thenar muscles, was less responsive than grip or tripod pinch testing using

  11. Comparing Prognostic Strength of Acute Corticospinal Tract Injury Measured by a New Diffusion Tensor Imaging Based Template Approach Versus Common Approaches

    PubMed Central

    Hirai, Kelsi K.; Groisser, Benjamin N.; Copen, William A.; Singhal, Aneesh B.; Schaechter, Judith D.

    2015-01-01

    Background Long-term motor outcome of acute stroke patients with severe motor impairment is difficult to predict. While measure of corticospinal tract (CST) injury based on diffusion tensor imaging (DTI) in subacute stroke patients strongly predicts motor outcome, its predictive value in acute stroke patients is unclear. Using a new DTI-based, density-weighted CST template approach, we demonstrated recently that CST injury measured in acute stroke patients with moderately-severe to severe motor impairment of the upper limb strongly predicts motor outcome of the limb at 6 months. New Method The current study compared the prognostic strength of CST injury measured in 10 acute stroke patients with moderately-severe to severe motor impairment of the upper limb by the new density-weighted CST template approach versus several variants of commonly used DTI-based approaches. Results and Comparison with Existing Methods Use of the density-weighted CST template approach yielded measurements of acute CST injury that correlated most strongly, in absolute magnitude, with 6-month upper limb strength (rs = 0.93), grip (rs = 0.94) and dexterity (rs = 0.89) compared to all other 11 approaches. Formal statistical comparison of correlation coefficients revealed that acute CST injury measured by the density-weighted CST template approach correlated significantly more strongly with 6-month upper limb strength, grip and dexterity than 9, 10 and 6 of the 11 alternative measurements, respectively. Conclusions Measurements of CST injury in acute stroke patients with substantial motor impairment by the density-weighted CST template approach may have clinical utility for anticipating healthcare needs and improving clinical trial design. PMID:26386285

  12. A minimalist approach to bias estimation for passive sensor measurements with targets of opportunity

    NASA Astrophysics Data System (ADS)

    Belfadel, Djedjiga; Osborne, Richard W.; Bar-Shalom, Yaakov

    2013-09-01

    In order to carry out data fusion, registration error correction is crucial in multisensor systems. This requires estimation of the sensor measurement biases. It is important to correct for these bias errors so that the multiple sensor measurements and/or tracks can be referenced as accurately as possible to a common tracking coordinate system. This paper provides a solution for bias estimation for the minimum number of passive sensors (two), when only targets of opportunity are available. The sensor measurements are assumed time-coincident (synchronous) and perfectly associated. Since these sensors provide only line of sight (LOS) measurements, the formation of a single composite Cartesian measurement obtained from fusing the LOS measurements from different sensors is needed to avoid the need for nonlinear filtering. We evaluate the Cramer-Rao Lower Bound (CRLB) on the covariance of the bias estimate, i.e., the quantification of the available information about the biases. Statistical tests on the results of simulations show that this method is statistically efficient, even for small sample sizes (as few as two sensors and six points on the trajectory of a single target of opportunity). We also show that the RMS position error is significantly improved with bias estimation compared with the target position estimation using the original biased measurements.

  13. Clinical Implications for Muscle Strength Differences in Women of Different Age and Racial Groups: The WIN Study.

    PubMed

    Trudelle-Jackson, Elaine; Ferro, Emerenciana; Morrow, James R

    2011-01-01

    BACKGROUND: Reduction in muscle strength is strongly associated with functional decline in women, and women with lower quadriceps strength adjusted for body weight are more likely to develop knee osteoarthritis. OBJECTIVE: To compare body weight--adjusted strength among women of different age/racial groups. STUDY DESIGN: Cross-sectional study of muscle strength in 918 women aged 20--83 (M ± SD = 52 ± 13). METHODS: An orthopedic examination was conducted including measurement of handgrip and lower extremity strength (hip abductors/external rotators, knee flexors/extensors). Data were grouped into young (20--39 years, n = 139), middle (40--54 years, n = 300), and older (55+ years, n = 424) ages for white (n = 699) and African American (AA) (n = 164) women. Means and standard deviations for strength adjusted for body weight were calculated for each age and racial group and compared using 2-way multivariate analysis of variance and post hoc tests. RESULTS: No significant age-by-race interaction (P = .092) but significant main effects for age and race (P < .001). Pairwise comparisons revealed significant differences in knee extensor and flexor strength between all age groups. For grip and hip external rotator strength, significant differences were found between the middle and older groups. Differences in hip abductor strength were found between the young and middle-aged groups. AA women had lower strength than white women in all muscle groups (P < .05) except hip external rotators. CONCLUSIONS: Strength decreased with age in all muscle groups but magnitude of decrease varied by muscle. Strengthening programs should target different muscles, depending on a woman's age and race.

  14. Measuring the Density of Liquid Targets in the SeaQuest Experiment

    NASA Astrophysics Data System (ADS)

    Xi, Zhaojia; SeaQuest/E906 Collaboration

    2015-10-01

    The SeaQuest (E906) experiment, using the 120 GeV proton beam from the Main Injector at the Fermi National Accelerator Lab (FNAL), is studying the quark and antiquark structure of the nucleon using the Drell-Yan process. Based on the cross section ratios, σ (p + d) / σ (p + p) , SeaQuest will extract the Bjorken-x dependnce of the d / u ratio. The measurement will cover the large region (x > 0 . 25) with improved accuracy compared to the previous E866/Nusea experiment. Liquid D2 (LD2) and Liquid H2 (LH2) are the targets used in the SeaQuest experiment. The densities of LD2 and LH2 targets are two important quantities for the determination of the d / u ratio. We measure the pressure and temperature inside the flasks, from which the densities are calculated. The method, measurements and results of this study will be presented. This work is supported by U.S. DOE MENP Grant DE-FG02-03ER41243.

  15. Size dependence of the disruption threshold: laboratory examination of millimeter-centimeter porous targets

    NASA Astrophysics Data System (ADS)

    Nakamura, Akiko M.; Yamane, Fumiya; Okamoto, Takaya; Takasawa, Susumu

    2015-03-01

    The outcome of collision between small solid bodies is characterized by the threshold energy density Q*s, the specific energy to shatter, that is defined as the ratio of projectile kinetic energy to the target mass (or the sum of target and projectile) needed to produce the largest intact fragment that contains one half the target mass. It is indicated theoretically and by numerical simulations that the disruption threshold Q*s decreases with target size in strength-dominated regime. The tendency was confirmed by laboratory impact experiments using non-porous rock targets (Housen and Holsapple, 1999; Nagaoka et al., 2014). In this study, we performed low-velocity impact disruption experiments on porous gypsum targets with porosity of 65-69% and of three different sizes to examine the size dependence of the disruption threshold for porous material. The gypsum specimens were shown to have a weaker volume dependence on static tensile strength than do the non-porous rocks. The disruption threshold had also a weaker dependence on size scale as Q*s ∝D-γ , γ ≤ 0.25 - 0.26, while the previous laboratory studies showed γ=0.40 for the non-porous rocks. The measurements at low-velocity lead to a value of about 100 J kg-1 for Q*s which is roughly one order of magnitude lower than the value of Q*s for the gypsum targets of 65% porosity but impacted by projectiles with higher velocities. Such a clear dependence on the impact velocity was also shown by previous studies of gypsum targets with porosity of 50%.

  16. Relationship of condom strength to failure during use.

    PubMed

    1980-10-01

    Less-than-ideal environmental conditions, especially in developing countries with tropical or desert climates, prolonged storage times because of unpredictable supply and distribution, and inexperience with warehousing and logistics causing haphazard turnover of stocks can accelerate deterioration of condoms and render them unsuitable for use. As condom strength standards have never been related directly to failure during use, a Program for the Introduction and Adaptation of Contraceptive Technology (PIACT) study, in collaboration with Planned Parenthood of Seattle-King County, Washington, was conducted to determine the actual relationship between condom strength and failure during use (see July 1980 issue of Contraception). The study found that: 1) air burst test parameters can effectively and sensitively measure changes in condom strength; 2) condoms produced by Western industrial standards exceed by a wide margin the minimum strength required for effective use; and 3) stored condoms should not necessarily be thrown out if they are uniform in strength, even though they fall below accepted standards for new condoms. The study also brought out the issue of condom packaging. The potent deteriorating effect of ultraviolet light on condoms is well-known, and it is therefore suggested that condoms be packaged in foil or opaque laminates on both sides. A separate study requested by the U.S. Agency for International Development investigating the relationship between the 2 tests for condom strength (air burst standards as used in the PIACT study and tensile strength measurements) showed that air burst data and tensile strength parameters closely reflected the same characteristics, thus providing support for the use of air burst strength measurements for predicting useful life of stored condoms.

  17. Synthetic Aperture Sonar Imaging of Simple Finite Targets

    DTIC Science & Technology

    2011-03-15

    again including the geometric spreading. The target strength of a sphere, as given by Urick [22], is TSs = 10 log10(a2/4), which yields TSs = −19.58...respectively. find TSis = 12.63− 52.04 + 20.00 = −19.41 dB, which compares favorably with Urick’s value. From Urick , the target strength of a finite cylinder...is now TSic = 9.08 − 27.51 + 20.00 = 1.57, which is again in good agreement with Urick . It is noted that a value of N = 21.7 reproduces TSc. The final

  18. POROSITY AND BAND-STRENGTH MEASUREMENTS OF MULTI-PHASE COMPOSITE ICES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bossa, Jean-Baptiste; Fransen, Coen; Cazaux, Stéphanie

    2015-11-20

    We use experimental mid-infrared optical constants and extended effective medium approximations to determine the porosity and the band strengths of multi-phase composite ices grown at 30 K. A set of porous H{sub 2}O:CH{sub 4} ices are taken as a prototypical example. As a benchmark and proof of concept, the stoichiometry of the ice constituents is retreived with good accuracy from the refractive indices and the extinction coefficients of the reference binary ice mixtures with known compositions. Accurate band strengths are then calculated from experimental mid-infrared spectra of complex ices. We notice that the presence of pores has only a smallmore » effect on the overall band strengths, whereas a water dilution can considerably alter them. Different levels of porosity are observed depending on the abundance of methane used as a gas contaminant premixed with water prior to background deposition. The absorption profiles are also found to vary with deposition rate. To explain this, we use Monte Carlo simulations and we observe that the deposition rate strongly affects the pore size distribution as well as the ice morphology through reorganization processes. Extrapolated to genuine interstellar ices, the methodology presented in this paper can be used to evaluate the porosity and to quantify the relative abundances from observational data.« less

  19. MFP scanner diagnostics using a self-printed target to measure the modulation transfer function

    NASA Astrophysics Data System (ADS)

    Wang, Weibao; Bauer, Peter; Wagner, Jerry; Allebach, Jan P.

    2014-01-01

    In the current market, reduction of warranty costs is an important avenue for improving profitability by manufacturers of printer products. Our goal is to develop an autonomous capability for diagnosis of printer and scanner caused defects with mid-range laser multifunction printers (MFPs), so as to reduce warranty costs. If the scanner unit of the MFP is not performing according to specification, this issue needs to be diagnosed. If there is a print quality issue, this can be diagnosed by printing a special test page that is resident in the firmware of the MFP unit, and then scanning it. However, the reliability of this process will be compromised if the scanner unit is defective. Thus, for both scanner and printer image quality issues, it is important to be able to properly evaluate the scanner performance. In this paper, we consider evaluation of the scanner performance by measuring its modulation transfer function (MTF). The MTF is a fundamental tool for assessing the performance of imaging systems. Several ways have been proposed to measure the MTF, all of which require a special target, for example a slanted-edge target. It is unacceptably expensive to ship every MFP with such a standard target, and to expect that the customer can keep track of it. To reduce this cost, in this paper, we develop new approach to this task. It is based on a self-printed slanted-edge target. Then, we propose algorithms to improve the results using a self-printed slanted-edge target. Finally, we present experimental results for MTF measurement using self-printed targets and compare them to the results obtained with standard targets.

  20. Effects of Partner's Improvisational Resistance Training on dancers' muscular strength.

    PubMed

    Vetter, Rheba E; Dorgo, Sandor

    2009-05-01

    The purpose of this study was to observe the effects of Partner's Improvisational Resistance Training (PIRT) on muscular strength, body circumference, and body fat percentage in 10 female college-age dancers in comparison with 8 female dancers in a control group. The PIRT program, based on the concepts of manual resistance training, is the application of contact improvisation in a systematic strength development program, which proposes a way of contextualizing muscular strength development within the dance class. The program lasted 8 weeks, meeting 3 times weekly for 60-minute sessions. The muscular strength pre- and posttests included 1-repetition maximum (1RM) for leg extension, leg flexion, leg press, bench press, lat pulldown, back extension, and modified sit-up. Hydrostatic weighing for body composition and circumference measures on the waist, hip, shoulder, upper arm, and thigh were made pre- and posttest analyses. There were no significant pretest differences between the groups for age, height, body weight, body fat percentage, any of the circumference measures, or 5 of the 7 muscular strength measures. At posttest, neither group showed significant changes in total body weight, body fat percentage, or lean body weight. The experimental group showed significant decrements in the waist and hip circumference measures, and all other body circumference changes were nonsignificant. The experimental group showed significant changes from pretest to posttest for all seven 1RM strength measures and greater absolute and relative strength improvements in 5 measures compared with the control group. Thus, the 8-week PIRT program for female dancers was found effective in improving overall muscular strength and decreasing circumference in the waist-hip region, but it did not elicit significant changes in body composition.

  1. Does grip strength reflect isokinetic muscle strength in lower limbs in patients with chronic inflammatory demyelinating polyneuropathy?

    PubMed

    Knak, Kirsten L; Andersen, Linda K; Christiansen, Ingelise; Markvardsen, Lars K

    2018-03-30

    Grip strength (GS) is a common measure of general muscle strength in patients with chronic inflammatory demyelinating polyneuropathy (CIDP). However, it is important to investigate the correlation and responsiveness of GS compared with isokinetic muscle strength (IKS) and function of the lower limbs. Seventy patients with CIDP were evaluated with GS, IKS, and functional measures of the lower limbs. Reevaluation was performed after 2 and 10/12 weeks. Correlation and response analyses were performed. GS correlated with IKS at the ankle (IKS ankle ; maximum Spearman's rank-order correlation [R S ] = 0.58) and with walking performance (maximum R S  = -0.38). IKS ankle was more responsive to detect change (standardized response mean [SRM] = 0.57) than GS (SRM = 0.27). GS does not seem to be an appropriate surrogate measure of IKS and function of the lower limbs in patients with CIDP. Muscle Nerve, 2018. © 2018 Wiley Periodicals, Inc.

  2. Measuring the Influence of Pearlite Dissolution on the Transient Dynamic Strength of Rapidly Heated Plain Carbon Steels

    NASA Astrophysics Data System (ADS)

    Mates, Steven; Stoudt, Mark; Gangireddy, Sindhura

    2016-07-01

    Carbon steels containing ferrite-pearlite microstructures weaken dramatically when pearlite dissolves into austenite on heating. The kinetics of this phase transformation, while fast, can play a role during dynamic, high-temperature manufacturing processes, including high-speed machining, when the time scale of this transformation is on the order of the manufacturing process itself. In such a regime, the mechanical strength of carbon steel can become time dependent. The present work uses a rapidly heated, high-strain-rate mechanical test to study the effect of temperature and time on the amount of pearlite dissolved and on the resulting transient effect on dynamic strength of a low and a high carbon (eutectoid) steel. Measurements indicate that the transient effect occurs for heating times less than about 3 s. The 1075 steel loses about twice the strength compared to the 1018 steel (85 MPa to 45 MPa) owing to its higher initial pearlite volume fraction. Pearlite dissolution is confirmed by metallographic examination of tested samples. Despite the different starting pearlite fractions, the kinetics of dissolution are comparable for the two steels, owing to the similarity in their initial pearlite morphology.

  3. Effect of a viscoelastic target on the impact response of a flat-nosed projectile

    NASA Astrophysics Data System (ADS)

    Liu, Hu; Yang, Jialing; Liu, Hua

    2018-02-01

    Taylor impact is a widely used strategy in which a flat-nosed projectile is fired onto a rigid anvil directly to determine the dynamic strength of rod specimens. Nowadays, the rigid anvil is often replaced by an output target bar to ensure the accuracy of measurement via recording strain signals in the output bar. For testing the dynamic strength of low-density materials, a low-impedance target bar, which exhibits viscoelastic characteristics is often employed. In this paper, an extended Taylor model is proposed to improve the idealization of treating the target bar as perfectly rigid material in the classic Taylor model, and the viscoelastic effect of the target bar is incorporated. The viscoelastic target bar is depicted by two elastic springs and one dashpot. Based on the plastic shock wave theory in the flat-nosed projectile associated with the viscoelastic wave analysis in the target bar, the viscoelastic effect of the target bar on the impact response of the flat-nosed projectile is investigated. The finite element simulation is also carried out to verify the theoretical model, and good agreement is found. The present theoretical model is also called the Taylor-cylinder Hopkinson impact, which provides a more accurate way to identify the dynamic material parameters. The dynamic responses of the present model are further compared with previous elastic and rigid target bar models. It is found that the viscoelastic effect of the target bar should be taken into consideration in the Taylor-cylinder Hopkinson impact test for low-impedance materials.

  4. Attack Detection in Sensor Network Target Localization Systems With Quantized Data

    NASA Astrophysics Data System (ADS)

    Zhang, Jiangfan; Wang, Xiaodong; Blum, Rick S.; Kaplan, Lance M.

    2018-04-01

    We consider a sensor network focused on target localization, where sensors measure the signal strength emitted from the target. Each measurement is quantized to one bit and sent to the fusion center. A general attack is considered at some sensors that attempts to cause the fusion center to produce an inaccurate estimation of the target location with a large mean-square-error. The attack is a combination of man-in-the-middle, hacking, and spoofing attacks that can effectively change both signals going into and coming out of the sensor nodes in a realistic manner. We show that the essential effect of attacks is to alter the estimated distance between the target and each attacked sensor to a different extent, giving rise to a geometric inconsistency among the attacked and unattacked sensors. Hence, with the help of two secure sensors, a class of detectors are proposed to detect the attacked sensors by scrutinizing the existence of the geometric inconsistency. We show that the false alarm and miss probabilities of the proposed detectors decrease exponentially as the number of measurement samples increases, which implies that for sufficiently large number of samples, the proposed detectors can identify the attacked and unattacked sensors with any required accuracy.

  5. Field strength measurements of speed measuring radar units

    DOT National Transportation Integrated Search

    1981-06-01

    The objective of this project was to measure the microwave radiation emitted by speed measuring radar units to obtain a data base for evaluating the potential radiation hazards of these devices. Measurements were taken both in free-space and with the...

  6. Tongue Strength is Associated with Grip Strength and Nutritional Status in Older Adult Inpatients of a Rehabilitation Hospital.

    PubMed

    Sakai, Kotomi; Nakayama, Enri; Tohara, Haruka; Maeda, Tomomi; Sugimoto, Motonobu; Takehisa, Takahiro; Takehisa, Yozo; Ueda, Koichiro

    2017-04-01

    The aim of this cross-sectional study was to investigate whether tongue strength observed in older adult inpatients of a rehabilitation hospital is associated with muscle function, nutritional status, and dysphagia. A total of 174 older adult inpatients aged 65 years and older in rehabilitation (64 men, 110 women; median age, 84 years; interquartile range, 80-89 years) who were suspected of having reduced tongue strength due to sarcopenia were included in this study. Isometric tongue strength was measured using a device fitted with a disposable oral balloon probe. We evaluated age, muscle function as assessed by the Barthel index and grip strength, nutritional status as measured by the Mini Nutritional Assessment-short form (MNA-SF), body mass index, serum albumin, controlling nutritional status, and calf circumference and arm muscle area to assess muscle mass. In addition, the functional oral intake scale (FOIS) was used as an index of dysphagia. Multivariate linear regression analysis revealed that isometric tongue strength was independently associated with grip strength (coefficient = 0.33, 95 % confidence interval (CI) 0.12-0.54, p = 0.002), MNA-SF (coefficient = 0.74, 95 % CI 0.12-1.35, p = 0.019), and FOIS (coefficient = 0.02, 95 % CI 0.00-0.15, p = 0.047). To maintain and improve tongue strength in association with sarcopenic dysphagia, exercise therapy and nutritional therapy interventions, as well as direct interventions to address tongue strength, may be effective in dysphagia rehabilitation in older adult inpatients.

  7. A comparison of manual and quantitative elbow strength testing.

    PubMed

    Shahgholi, Leili; Bengtson, Keith A; Bishop, Allen T; Shin, Alexander Y; Spinner, Robert J; Basford, Jeffrey R; Kaufman, Kenton R

    2012-10-01

    The aim of this study was to compare the clinical ratings of elbow strength obtained by skilled clinicians with objective strength measurement obtained through quantitative testing. A retrospective comparison of subject clinical records with quantitative strength testing results in a motion analysis laboratory was conducted. A total of 110 individuals between the ages of 8 and 65 yrs with traumatic brachial plexus injuries were identified. Patients underwent manual muscle strength testing as assessed on the 5-point British Medical Research Council Scale (5/5, normal; 0/5, absent) and quantitative elbow flexion and extension strength measurements. A total of 92 subjects had elbow flexion testing. Half of the subjects clinically assessed as having normal (5/5) elbow flexion strength on manual muscle testing exhibited less than 42% of their age-expected strength on quantitative testing. Eighty-four subjects had elbow extension strength testing. Similarly, half of those displaying normal elbow extension strength on manual muscle testing were found to have less than 62% of their age-expected values on quantitative testing. Significant differences between manual muscle testing and quantitative findings were not detected for the lesser (0-4) strength grades. Manual muscle testing, even when performed by experienced clinicians, may be more misleading than expected for subjects graded as having normal (5/5) strength. Manual muscle testing estimates for the lesser strength grades (1-4/5) seem reasonably accurate.

  8. Body Composition, Strength, and Dietary Intake of Patients with Hip or Knee Osteoarthritis.

    PubMed

    Purcell, Sarah; Thornberry, Robert; Elliott, Sarah A; Panton, Lynn; Ormsbee, Michael J; Vieira, Edgar R; Kim, Jeong-Su; Prado, Carla M

    2016-06-01

    To describe body composition (fat mass (FM) and fat-free mass (FFM)), strength, and nutritional characteristics of patients with hip or knee osteoarthritis undergoing total joint arthroplasty. In this prospective pilot study, osteoarthritic patients underwent body composition assessment using bioelectrical impedance analysis, grip strength measurement, and completed a 24-h dietary recall during their pre-operative assessment. Fifty-five patients were included (∼66% females, age 43-89 years). Mean ± SD body mass index (BMI) was 32.79 ± 6.48 kg/m(2) and 62% were obese. Compared with hip osteoarthritis patients, knee osteoarthritis patients had a higher BMI (P = 0.018) and males with knee osteoarthritis had a lower grip strength (P = 0.028). There was a wide range in FM and FFM values across the BMI spectrum. Patients with a higher FM index (FMI, FM/height in m(2)) had higher levels of pain (P = 0.036) and females with higher FMI had a lower grip strength (P = 0.048). Dietary under-reporting was common and many patients did not meet recommendations for protein, vitamins C and E, or omega-3 fatty acids. Those who consumed less protein than the recommended dietary allowance were older (P = 0.018). A wide variability of body composition and dietary intake was observed which may impact strength and ultimately affect physical function. As such, patients with osteoarthritis may benefit from targeted nutrition and physical activity interventions before and after surgery.

  9. Protective Effects of Psychological Strengths Against Psychiatric Disorders Among Soldiers.

    PubMed

    Shrestha, Alice; Cornum, B G Rhonda; Vie, Loryana L; Scheier, Lawrence M; Lester, M A J Paul B; Seligman, Martin E P

    2018-03-01

    This study prospectively examined psychological strengths targeted in U.S. Army training programs as predictors of psychiatric diagnosis in active duty soldiers. At baseline, the cohort (140,584 soldiers) was without psychiatric disorder. Soldiers were then followed for 2 yr and classified as healthy, or acquiring a psychiatric diagnosis (adjustment disorder, anxiety disorder, depression, or post-traumatic stress disorder), or being prescribed psychotropic medication without a psychiatric diagnosis. Soldiers who remained healthy reported significantly higher strengths scores at baseline, compared with soldiers who were diagnosed with a psychiatric disorder. In addition, soldiers in the worst strengths decile were twice as likely to develop a psychiatric disorder, compared with soldiers in the top 50% on baseline strengths. Strengths afforded the greatest protection against depression. Offering tailored resilience training programs could help the Army steel vulnerable soldiers against the challenges of life, military training, and combat.

  10. Free-form reticulated shell structures searched for maximum buckling strength

    NASA Astrophysics Data System (ADS)

    Takiuchi, Yuji; Kato, Shiro; Nakazawa, Shoji

    2017-10-01

    In this paper, a scheme of shape optimization is proposed for maximum buckling strength of free-form steel reticulated shells. In order to discuss the effectiveness of objective functions with respect to maximizing buckling strength, several different optimizations are applied to shallow steel single layer reticulated shells targeting rigidly jointed tubular members. The objective functions to be compared are linear buckling load, strain energy, initial yield load, and elasto-plastic buckling strength evaluated based on Modified Dunkerley Formula. With respect to obtained free-forms based on the four optimization schemes, both of their elastic buckling and elasto-plastic buckling behaviour are investigated and compared considering geometrical imperfections. As a result, it is concluded that the first and fourth optimization methods are effective from a viewpoint of buckling strength. And the relation between generalized slenderness ratio and appropriate objective function applied in buckling strength maximization is made clear.

  11. Energy dependence of the ratio of isovector effective interaction strengths |JστJτ| from 0° (p,n) cross sections

    NASA Astrophysics Data System (ADS)

    Taddeucci, T. N.; Rapaport, J.; Bainum, D. E.; Goodman, C. D.; Foster, C. C.; Gaarde, C.; Larsen, J.; Goulding, C. A.; Horen, D. J.; Masterson, T.; Sugarbaker, E.

    1982-02-01

    Information concerning the ratio of the isovector effective interaction strengths |JστJτ| may be obtained from the ratio of (p,n) Gamow-Teller and isobaric analog state 0° differential cross sections. We have examined 0° (p,n) data for the energy range 5-200 MeV and find that for energies larger than 50 MeV and for targets with A=7-42 the product of the interaction-strength and distortion-factor ratios |JστJτ|(NστNτ)12 appears to be mass independent and linear as a function of bombarding energy. NUCLEAR REACTIONS 7Li, 13, 14C, 26Mg, 37Cl, 41Ca(p,n), measured σ(θ=0°), GT, IAS transitions, Ep=60-200 MeV. Deduced energy dependence, interaction strength ratio |JστJτ|.

  12. Sensor networks for optimal target localization with bearings-only measurements in constrained three-dimensional scenarios.

    PubMed

    Moreno-Salinas, David; Pascoal, Antonio; Aranda, Joaquin

    2013-08-12

    In this paper, we address the problem of determining the optimal geometric configuration of an acoustic sensor network that will maximize the angle-related information available for underwater target positioning. In the set-up adopted, a set of autonomous vehicles carries a network of acoustic units that measure the elevation and azimuth angles between a target and each of the receivers on board the vehicles. It is assumed that the angle measurements are corrupted by white Gaussian noise, the variance of which is distance-dependent. Using tools from estimation theory, the problem is converted into that of minimizing, by proper choice of the sensor positions, the trace of the inverse of the Fisher Information Matrix (also called the Cramer-Rao Bound matrix) to determine the sensor configuration that yields the minimum possible covariance of any unbiased target estimator. It is shown that the optimal configuration of the sensors depends explicitly on the intensity of the measurement noise, the constraints imposed on the sensor configuration, the target depth and the probabilistic distribution that defines the prior uncertainty in the target position. Simulation examples illustrate the key results derived.

  13. Improving quantum state transfer efficiency and entanglement distribution in binary tree spin network through incomplete collapsing measurements

    NASA Astrophysics Data System (ADS)

    Behzadi, Naghi; Ahansaz, Bahram

    2018-04-01

    We propose a mechanism for quantum state transfer (QST) over a binary tree spin network on the basis of incomplete collapsing measurements. To this aim, we perform initially a weak measurement (WM) on the central qubit of the binary tree network where the state of our concern has been prepared on that qubit. After the time evolution of the whole system, a quantum measurement reversal (QMR) is performed on a chosen target qubit. By taking optimal value for the strength of QMR, it is shown that the QST quality from the sending qubit to any typical target qubit on the binary tree is considerably improved in terms of the WM strength. Also, we show that how high-quality entanglement distribution over the binary tree network is achievable by using this approach.

  14. A NEW CLINICAL MUSCLE FUNCTION TEST FOR ASSESSMENT OF HIP EXTERNAL ROTATION STRENGTH: AUGUSTSSON STRENGTH TEST.

    PubMed

    Augustsson, Jesper

    2016-08-01

    Dynamic clinical tests of hip strength applicable on patients, non-athletes and athletes alike, are lacking. The aim of this study was therefore to develop and evaluate the reliability of a dynamic muscle function test of hip external rotation strength, using a novel device. A second aim was to determine if gender differences exist in absolute and relative hip strength using the new test. Fifty-three healthy sport science students (34 women and 19 men) were tested for hip external rotation strength using a device that consisted of a strap connected in series with an elastic resistance band loop, and a measuring tape connected in parallel with the elastic resistance band. The test was carried out with the subject side lying, positioned in 45 ° of hip flexion and the knees flexed to 90 ° with the device firmly fastened proximally across the knees. The subject then exerted maximal concentric hip external rotation force against the device thereby extending the elastic resistance band. The displacement achieved by the subject was documented by the tape measure and the corresponding force production was calculated. Both right and left hip strength was measured. Fifteen of the subjects were tested on repeated occasions to evaluate test-retest reliability. No significant test-retest differences were observed. Intra-class correlation coefficients ranged 0.93-0.94 and coefficients of variation 2.76-4.60%. In absolute values, men were significantly stronger in hip external rotation than women (right side 13.2 vs 11.0 kg, p = 0.001, left side 13.2 vs 11.5 kg, p = 0.002). There were no significant differences in hip external rotation strength normalized for body weight (BW) between men and women (right side 0.17 kg/BW vs 0.17 kg/BW, p = 0.675, left side 0.17 kg/BW vs 0.18 kg/BW, p = 0.156). The new muscle function test showed high reliability and thus could be useful for measuring dynamic hip external rotation strength in patients, non-athletes and athletes

  15. Personality Typology in Relation to Muscle Strength

    PubMed Central

    Terracciano, Antonio; Milaneschi, Yuri; Metter, E. Jeffrey; Ferrucci, Luigi

    2011-01-01

    Background Physical inactivity plays a central role in the age-related decline in muscle strength, an important component in the process leading to disability. Personality, a significant determinant of health behaviors including physical activity, could therefore impact muscle strength throughout adulthood and affect the rate of muscle strength decline with aging. Personality typologies combining “high neuroticism” (N≥55), “low extraversion” (E<45), and “low conscientiousness” (C<45) have been associated with multiple risky health behaviors but have not been investigated with regards to muscle strength. Purpose The purpose of this study is to investigate associations between individual and combined typologies consisting of high N, low E, and low C and muscle strength, and whether physical activity and body mass index act as mediators. Method This cross-sectional study includes 1,220 participants from the Baltimore Longitudinal Study of Aging. Results High N was found among 18%, low E among 31%, and low C among 26% of the sample. High levels of N, particularly when combined with either low E or low C, were associated with lower muscle strength compared with having only one or none of these personality types. Facet analyses suggest an important role for the N components of depression and hostility. Physical activity level appears to partly explain some of these associations. Conclusion Findings provide support for the notion that the typological approach to personality may be useful in identifying specific personality types at risk of low muscle strength and offer the possibility for more targeted prevention and intervention programs. PMID:21614452

  16. Development, validity and reliability of a new pressure air biofeedback device (PAB) for measuring isometric extension strength of the lumbar spine.

    PubMed

    Pienaar, Andries W; Barnard, Justhinus G

    2017-04-01

    This study describes the development of a new portable muscle testing device, using air pressure as a biofeedback and strength testing tool. For this purpose, a pressure air biofeedback device (PAB ® ) was developed to measure and record the isometric extension strength of the lumbar multifidus muscle in asymptomatic and low back pain (LBP) persons. A total of 42 subjects (age 47.58 years, ±18.58) participated in this study. The validity of PAB ® was assessed by comparing a selected measure, air pressure force in millibar (mb), to a standard criterion; calibrated weights in kilograms (kg) during day-to-day tests. Furthermore, clinical trial-to-trial and day-to-day tests of maximum voluntary isometric contraction (MVIC) of L5 lumbar multifidus were done to compare air pressure force (mb) to electromyography (EMG) in microvolt (μV) and to measure the reliability of PAB ® . A highly significant relationship were found between air pressure output (mb) and calibrated weights (kg). In addition, Pearson correlation calculations showed a significant relationship between PAB ® force (mb) and EMG activity (μV) for all subjects (n = 42) examined, as well as for the asymptomatic group (n = 24). No relationship was detected for the LBP group (n = 18). In terms of lumbar extension strength, we found that asymptomatic subjects were significantly stronger than LBP subjects. The results of the PAB ® test differentiated between LBP and asymptomatic subject's lumbar isometric extension strength without any risk to the subjects and also indicate that the lumbar isometric extension test with the new PAB ® device is reliable and valid.

  17. Effect of an eccentrically biased hamstring strengthening home program on knee flexor strength and the length-tension relationship.

    PubMed

    Orishimo, Karl F; McHugh, Malachy P

    2015-03-01

    The purposes of this study were to document relative activation intensities of the hamstrings and gluteus maximus during 4 eccentric hamstring strengthening exercises and to assess the effects of a short-term strengthening program comprised of these exercises on knee flexor strength and the length-tension relationship. Twelve healthy subjects participated in this study. Electromyographic (EMG) activities from the biceps femoris, semitendinosus, and gluteus maximus were recorded as subjects performed (a) standing hip extension with elastic resistance, (b) trunk flexion in single limb stance (diver), (c) standing split (glider), and (d) supine sliding bridge (slider). Baseline isometric knee flexor strength was measured at 90, 70, 50, and 30° of flexion at the knee with the subject seated and the hip flexed to 50° from horizontal. After completing the 4-week training program, strength tests were repeated. Repeated-measures analysis of variance were used to compare EMG activity between muscles and to assess angle-specific strength improvements. Hamstring activity exceeded gluteus maximus activity for resisted hip extension, glider, and slider exercises (p < 0.001) but not for the diver (p = 0.087). Hamstring activation was greatest during the slider and resisted hip extension and lowest during the glider and the diver. Knee flexor strength improved by 9.0% (p = 0.005) but was not angle specific (training by angle p = 0.874). The short-term home training program effectively targeted the hamstrings and resulted in strength gains that were similar at short and long muscle lengths. These data demonstrate that hamstring strength can be improved using eccentrically biased unilateral exercises without the use of weights or other equipments.

  18. Associations Between Measures of Balance and Lower-Extremity Muscle Strength/Power in Healthy Individuals Across the Lifespan: A Systematic Review and Meta-Analysis.

    PubMed

    Muehlbauer, Thomas; Gollhofer, Albert; Granacher, Urs

    2015-12-01

    It has frequently been reported that balance and lower-extremity muscle strength/power are associated with sports-related and everyday activities. Knowledge about the relationship between balance, strength, and power are important for the identification of at-risk individuals because deficits in these neuromuscular components are associated with an increased risk of sustaining injuries and falls. In addition, this knowledge is of high relevance for the development of specifically tailored health and skill-related exercise programs. The objectives of this systematic literature review and meta-analysis were to characterize and, if possible, quantify associations between variables of balance and lower-extremity muscle strength/power in healthy individuals across the lifespan. A computerized systematic literature search was performed in the electronic databases PubMed, Web of Science, and SPORTDiscus up to March 2015 to capture all relevant articles. A systematic approach was used to evaluate the 996 articles identified for initial review. Studies were included only if they investigated healthy individuals aged ≥6 years and tested at least one measure of static steady-state balance (e.g., center of pressure [CoP] displacement during one-legged stance), dynamic steady-state balance (e.g., gait speed), proactive balance (e.g., distance in the functional-reach-test), or reactive balance (e.g., CoP displacement during perturbed one-legged stance), and one measure of maximal strength (e.g., maximum voluntary contraction), explosive force (e.g., rate of force development), or muscle power (e.g., jump height). In total, 37 studies met the inclusionary criteria for review. The included studies were coded for the following criteria: age (i.e., children: 6-12 years, adolescents: 13-18 years, young adults: 19-44 years, middle-aged adults: 45-64 years, old adults: ≥65 years), sex (i.e., female, male), and test modality/outcome (i.e., test for the assessment of balance

  19. Determining Criteria to Predict Repeatability of Performance in Older Adults: Using Coefficients of Variation for Strength and Functional Measures.

    PubMed

    Raj, Isaac Selva; Bird, Stephen R; Westfold, Ben A; Shield, Anthony J

    2017-01-01

    Reliable measures of muscle strength and functional capacity in older adults are essential. The aim of this study was to determine whether coefficients of variation (CVs) of individuals obtained at the first session can infer repeatability of performance in a subsequent session. Forty-eight healthy older adults (mean age 68.6 ± 6.1 years; age range 60-80 years) completed two assessment sessions, and on each occasion undertook: dynamometry for isometric and isokinetic quadriceps strength, 6 meter fast walk (6MFWT), timed up and go (TUG), stair climb and descent, and vertical jump. Significant linear relationships were observed between CVs in session 1 and the percentage difference between sessions 1 and 2 for torque at 60, 120, 240 and 360°/s, 6MFWT, TUG, stair climb, and stair descent. The results of this study could be used to establish criteria for determining an acceptably reliable performance in strength and functional tests.

  20. High affinity γPNA sandwich hybridization assay for rapid detection of short nucleic acid targets with single mismatch discrimination.

    PubMed

    Goldman, Johnathan M; Zhang, Li Ang; Manna, Arunava; Armitage, Bruce A; Ly, Danith H; Schneider, James W

    2013-07-08

    Hybridization analysis of short DNA and RNA targets presents many challenges for detection. The commonly employed sandwich hybridization approach cannot be implemented for these short targets due to insufficient probe-target binding strengths for unmodified DNA probes. Here, we present a method capable of rapid and stable sandwich hybridization detection for 22 nucleotide DNA and RNA targets. Stable hybridization is achieved using an n-alkylated, polyethylene glycol γ-carbon modified peptide nucleic acid (γPNA) amphiphile. The γPNA's exceptionally high affinity enables stable hybridization of a second DNA-based probe to the remaining bases of the short target. Upon hybridization of both probes, an electrophoretic mobility shift is measured via interaction of the n-alkane modification on the γPNA with capillary electrophoresis running buffer containing nonionic surfactant micelles. We find that sandwich hybridization of both probes is stable under multiple binding configurations and demonstrate single base mismatch discrimination. The binding strength of both probes is also stabilized via coaxial stacking on adjacent hybridization to targets. We conclude with a discussion on the implementation of the proposed sandwich hybridization assay as a high-throughput microRNA detection method.

  1. The German Version of the Strengths Use Scale: The Relation of Using Individual Strengths and Well-being.

    PubMed

    Huber, Alexandra; Webb, Dave; Höfer, Stefan

    2017-01-01

    Theoretical perspectives in positive psychology have considered the possession and use of strengths equally but in applied research more studies focused on having them, probably due to the absence of psychometrically adequate scales. Therefore, the aim of this study was to assess the psychometric characteristics of the German language version of the Strengths Use Scale (SUS) and to explore relationships between strengths use and several indicator measures of well-being: the presence of positive and the absence of negative affect, self-esteem as identity aspect, vitality as self-regulatory resource, and stress for capturing the evaluation of difficulties and obstacles impinging on well-being. The original English version of the SUS was translated following recommended independent forward-backward translation techniques. Exploratory and confirmatory factor analyses were conducted, including a German-speaking convenience sample of university students ( N = 374). Additionally, the relations of strengths use and well-being indicators were analyzed. Factorial validity revealed a single-factor structure of the German version of the SUS, explaining 58.4% variance (factor loadings: 0.58 to 0.86), approving the scale's design and showing high internal consistency (Cronbach's α 0.95). The hypothesized positive relationships of strengths use with positive affect, self-esteem, and vitality were confirmed as well as the negative relationships with negative affect and stress. The German version of the SUS is psychometrically sound and data indicate that individual strengths use and well-being related measures interact. The instrument can be recommended for future research questions such as if and how the promotion of applying individual strengths during education enhances levels of well-being, or how the implementation of strengths use in job-design guidelines or working conditions can result in higher levels of well-being or healthiness.

  2. The German Version of the Strengths Use Scale: The Relation of Using Individual Strengths and Well-being

    PubMed Central

    Huber, Alexandra; Webb, Dave; Höfer, Stefan

    2017-01-01

    Theoretical perspectives in positive psychology have considered the possession and use of strengths equally but in applied research more studies focused on having them, probably due to the absence of psychometrically adequate scales. Therefore, the aim of this study was to assess the psychometric characteristics of the German language version of the Strengths Use Scale (SUS) and to explore relationships between strengths use and several indicator measures of well-being: the presence of positive and the absence of negative affect, self-esteem as identity aspect, vitality as self-regulatory resource, and stress for capturing the evaluation of difficulties and obstacles impinging on well-being. The original English version of the SUS was translated following recommended independent forward-backward translation techniques. Exploratory and confirmatory factor analyses were conducted, including a German-speaking convenience sample of university students (N = 374). Additionally, the relations of strengths use and well-being indicators were analyzed. Factorial validity revealed a single-factor structure of the German version of the SUS, explaining 58.4% variance (factor loadings: 0.58 to 0.86), approving the scale’s design and showing high internal consistency (Cronbach’s α 0.95). The hypothesized positive relationships of strengths use with positive affect, self-esteem, and vitality were confirmed as well as the negative relationships with negative affect and stress. The German version of the SUS is psychometrically sound and data indicate that individual strengths use and well-being related measures interact. The instrument can be recommended for future research questions such as if and how the promotion of applying individual strengths during education enhances levels of well-being, or how the implementation of strengths use in job-design guidelines or working conditions can result in higher levels of well-being or healthiness. PMID:28496424

  3. Investigation of the relationship between anthropometric measurements and maximal handgrip strength in young adults.

    PubMed

    Eidson, Christopher A; Jenkins, Gavin R; Yuen, Hon K; Abernathy, Anne M; Brannon, Mary Beth; Pung, Anna R; Ward, Kiara D; Weaver, Tara E

    2017-01-01

    To identify physical measures that predict maximal handgrip strength (MHGS) and provide evidence for identifying lack of sincerity of effort when assessing upper extremity weakness. This study investigated anthropometric measurements associated with MHGS of healthy young adults. A convenience sample of 150 healthy adults ages 19 to 34 years old completed the MHGS assessment, which was measured using a Jamar dynamometer according to the protocol of the American Society of Hand Therapists, for both dominant and non-dominant hands. Several anthropometric data were collected, which included height, body weight, forearm length, forearm circumference, hand length, and hand width. Multivariable linear regression analysis indicated gender and hand width were uniquely and significantly associated with participants' MHGS for dominant and non-dominant hand and accounted for more than 60% of the variance, with R2 = 0.60, P < 0.001 for the dominant hand model and R2 = 0.64, P < 0.001 for the non-dominant hand model. Among the forearm and hand anthropometric measures, hand width is the best predictor of MHGS in both the non-dominant and dominant hands for healthy young adults.

  4. Artificially modified collagen fibril orientation affects leather tear strength.

    PubMed

    Kelly, Susyn J; Wells, Hannah C; Sizeland, Katie H; Kirby, Nigel; Edmonds, Richard L; Ryan, Tim; Hawley, Adrian; Mudie, Stephen; Haverkamp, Richard G

    2018-07-01

    Ovine leather has around half the tear strength of bovine leather and is therefore not suitable for high-value applications such as shoes. Tear strength has been correlated with the natural collagen fibril alignment (orientation index, OI). It is hypothesized that it could be possible to artificially increase the OI of the collagen fibrils and that an artificial increase in OI could increase tear strength. Ovine skins, after pickling and bating, were strained biaxially during chrome tanning. The strain ranged from 2 to 15% of the initial sample length, either uniformly in both directions by 10% or with 3% in one direction and 15% in the other. Once tanned, the leather tear strengths were measured and the collagen fibril orientation was measured using synchrotron-based small-angle X-ray scattering. The OI increased as a result of strain during tanning from 0.48 to 0.79 (P = 0.001) measured edge-on and the thickness-normalized tear strength increased from 27 to 43 N mm -1 (P < 0.001) after leather was strained 10% in two orthogonal directions. This is evidence to support a causal relationship between high OI (measured edge-on), highly influenced by thickness, and tear strength. It also provides a method to produce stronger leather. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  5. Correlation of pull-out strength of cement-augmented pedicle screws with CT-volumetric measurement of cement.

    PubMed

    Fölsch, Christian; Goost, Hans; Figiel, Jens; Paletta, Jürgen R J; Schultz, Wolfgang; Lakemeier, Stefan

    2012-12-01

    Cement augmentation of pedicle screws increases fixation strength in an osteoporotic spine. This study was designed to determine the cement distribution and the correlation between the pull-out strength of the augmented screw and the cement volume within polyurethane (PU) foam. Twenty-eight cannulated pedicle screws (6×45 mm) (Peter Brehm, Erlangen, Germany) with four holes at the distal end of the screw were augmented with the acrylic Stabilit ER Bone Cement Vertebral Augmentation System (DFine Inc., San Jose, CA, USA) and implanted into open-cell rigid PU foam (Pacific Research Laboratories, Vashon Island, WA, USA) with a density of 0.12 g/cm3, resembling severe osteoporosis. Volumetric measurement of the cement with consideration of the distribution around the screws was done with multislice computed tomography scan (Somatom Definition, Siemens, Erlangen, Germany). Pull-out strength was tested with a servohydraulic system (MTS System Corporation, Eden Prairie, MN, USA), and nonaugmented screws served as control. Pearson's correlation coefficient with significance level α=0.05 and one-way analysis of variance test were used. We found a high (r=0.88) and significant (p<0.01) correlation between the cement volume and the pull-out strength, which increased by more than 5-fold with a volume of 3 ml. The correlation appeared linear at least up to 4 ml cement volume and failure always occurred at the cement-bone interface. The cement distribution was symmetric and circular around the most proximal hole, with a distance of 14 mm from the tip, and nearly 90% of the cement was found 6 mm distal and cranial to it. The 95% confidence interval for the relative amount of cement was 37%-41% within 2 mm of the most proximal hole. Compared with the control, a cement volume between 2.0 and 3.0 ml increased the pull-out strength significantly and is relevant for clinical purposes, whereas a volume of 0.5 ml did not. A cement volume beyond 3.0 ml should further increase the pull

  6. Strengths-based positive psychology interventions: a randomized placebo-controlled online trial on long-term effects for a signature strengths- vs. a lesser strengths-intervention.

    PubMed

    Proyer, René T; Gander, Fabian; Wellenzohn, Sara; Ruch, Willibald

    2015-01-01

    Recent years have seen an increasing interest in research in positive psychology interventions. There is broad evidence for their effectiveness in increasing well-being and ameliorating depression. Intentional activities that focus on those character strengths, which are most typical for a person (i.e., signature strengths, SS) and encourage their usage in a new way have been identified as highly effective. The current study aims at comparing an intervention aimed at using SS with one on using individual low scoring (or lesser) strengths in a randomized placebo-controlled trial. A total of 375 adults were randomly assigned to one of the two intervention conditions [i.e., using five signature vs. five lesser strengths (LS) in a new way] or a placebo control condition (i.e., early memories). We measured happiness and depressive symptoms at five time points (i.e., pre- and post-test, 1-, 3-, and 6-months follow-ups) and character strengths at pre-test. The main findings are that (1) there were increases in happiness for up to 3 months and decreases in depressive symptoms in the short term in both intervention conditions; (2) participants found working with strengths equally rewarding (enjoyment and benefit) in both conditions; (3) those participants that reported generally higher levels of strengths benefitted more from working on LS rather than SS and those with comparatively lower levels of strengths tended to benefit more from working on SS; and (4) deviations from an average profile derived from a large sample of German-speakers completing the Values-in-Action Inventory of Strengths were associated with greater benefit from the interventions in the SS-condition. We conclude that working on character strengths is effective for increasing happiness and discuss how these interventions could be tailored to the individual for promoting their effectiveness.

  7. Pose measurement method and experiments for high-speed rolling targets in a wind tunnel.

    PubMed

    Jia, Zhenyuan; Ma, Xin; Liu, Wei; Lu, Wenbo; Li, Xiao; Chen, Ling; Wang, Zhengqu; Cui, Xiaochun

    2014-12-12

    High-precision wind tunnel simulation tests play an important role in aircraft design and manufacture. In this study, a high-speed pose vision measurement method is proposed for high-speed and rolling targets in a supersonic wind tunnel. To obtain images with high signal-to-noise ratio and avoid impacts on the aerodynamic shape of the rolling targets, a high-speed image acquisition method based on ultrathin retro-reflection markers is presented. Since markers are small-sized and some of them may be lost when the target is rolling, a novel markers layout with which markers are distributed evenly on the surface is proposed based on a spatial coding method to achieve highly accurate pose information. Additionally, a pose acquisition is carried out according to the mentioned markers layout after removing mismatching points by Case Deletion Diagnostics. Finally, experiments on measuring the pose parameters of high-speed targets in the laboratory and in a supersonic wind tunnel are conducted to verify the feasibility and effectiveness of the proposed method. Experimental results indicate that the position measurement precision is less than 0.16 mm, the pitching and yaw angle precision less than 0.132° and the roll angle precision 0.712°.

  8. Pose Measurement Method and Experiments for High-Speed Rolling Targets in a Wind Tunnel

    PubMed Central

    Jia, Zhenyuan; Ma, Xin; Liu, Wei; Lu, Wenbo; Li, Xiao; Chen, Ling; Wang, Zhengqu; Cui, Xiaochun

    2014-01-01

    High-precision wind tunnel simulation tests play an important role in aircraft design and manufacture. In this study, a high-speed pose vision measurement method is proposed for high-speed and rolling targets in a supersonic wind tunnel. To obtain images with high signal-to-noise ratio and avoid impacts on the aerodynamic shape of the rolling targets, a high-speed image acquisition method based on ultrathin retro-reflection markers is presented. Since markers are small-sized and some of them may be lost when the target is rolling, a novel markers layout with which markers are distributed evenly on the surface is proposed based on a spatial coding method to achieve highly accurate pose information. Additionally, a pose acquisition is carried out according to the mentioned markers layout after removing mismatching points by Case Deletion Diagnostics. Finally, experiments on measuring the pose parameters of high-speed targets in the laboratory and in a supersonic wind tunnel are conducted to verify the feasibility and effectiveness of the proposed method. Experimental results indicate that the position measurement precision is less than 0.16 mm, the pitching and yaw angle precision less than 0.132° and the roll angle precision 0.712°. PMID:25615732

  9. Magnetic nanoparticles with high specific absorption rate of electromagnetic energy at low field strength for hyperthermia therapy

    PubMed Central

    Stigliano, Robert; Baker, Ian

    2015-01-01

    Magnetic nanoparticles (MNPs), referred to as the Dartmouth MNPs, which exhibit high specific absorption rate at low applied field strength have been developed for hyperthermia therapy applications. The MNPs consist of small (2–5 nm) single crystals of gamma-Fe2O3 with saccharide chains implanted in their crystalline structure, forming 20–40 nm flower-like aggregates with a hydrodynamic diameter of 110–120 nm. The MNPs form stable (>12 months) colloidal solutions in water and exhibit no hysteresis under an applied quasistatic magnetic field, and produce a significant amount of heat at field strengths as low as 100 Oe at 99–164 kHz. The MNP heating mechanisms under an alternating magnetic field (AMF) are discussed and analyzed quantitatively based on (a) the calculated multi-scale MNP interactions obtained using a three dimensional numerical model called the method of auxiliary sources, (b) measured MNP frequency spectra, and (c) quantified MNP friction losses based on magneto-viscous theory. The frequency responses and hysteresis curves of the Dartmouth MNPs are measured and compared to the modeled data. The specific absorption rate of the particles is measured at various AMF strengths and frequencies, and compared to commercially available MNPs. The comparisons demonstrate the superior heating properties of the Dartmouth MNPs at low field strengths (<250 Oe). This may extend MNP hyperthermia therapy to deeper tumors that were previously non-viable targets, potentially enabling the treatment of some of the most difficult cancers, such as pancreatic and rectal cancers, without damaging normal tissue. PMID:25825545

  10. Magnetic nanoparticles with high specific absorption rate of electromagnetic energy at low field strength for hyperthermia therapy

    NASA Astrophysics Data System (ADS)

    Shubitidze, Fridon; Kekalo, Katsiaryna; Stigliano, Robert; Baker, Ian

    2015-03-01

    Magnetic nanoparticles (MNPs), referred to as the Dartmouth MNPs, which exhibit high specific absorption rate at low applied field strength have been developed for hyperthermia therapy applications. The MNPs consist of small (2-5 nm) single crystals of gamma-Fe2O3 with saccharide chains implanted in their crystalline structure, forming 20-40 nm flower-like aggregates with a hydrodynamic diameter of 110-120 nm. The MNPs form stable (>12 months) colloidal solutions in water and exhibit no hysteresis under an applied quasistatic magnetic field, and produce a significant amount of heat at field strengths as low as 100 Oe at 99-164 kHz. The MNP heating mechanisms under an alternating magnetic field (AMF) are discussed and analyzed quantitatively based on (a) the calculated multi-scale MNP interactions obtained using a three dimensional numerical model called the method of auxiliary sources, (b) measured MNP frequency spectra, and (c) quantified MNP friction losses based on magneto-viscous theory. The frequency responses and hysteresis curves of the Dartmouth MNPs are measured and compared to the modeled data. The specific absorption rate of the particles is measured at various AMF strengths and frequencies, and compared to commercially available MNPs. The comparisons demonstrate the superior heating properties of the Dartmouth MNPs at low field strengths (<250 Oe). This may extend MNP hyperthermia therapy to deeper tumors that were previously non-viable targets, potentially enabling the treatment of some of the most difficult cancers, such as pancreatic and rectal cancers, without damaging normal tissue.

  11. Magnetic nanoparticles with high specific absorption rate of electromagnetic energy at low field strength for hyperthermia therapy.

    PubMed

    Shubitidze, Fridon; Kekalo, Katsiaryna; Stigliano, Robert; Baker, Ian

    2015-03-07

    Magnetic nanoparticles (MNPs), referred to as the Dartmouth MNPs, which exhibit high specific absorption rate at low applied field strength have been developed for hyperthermia therapy applications. The MNPs consist of small (2-5 nm) single crystals of gamma-Fe 2 O 3 with saccharide chains implanted in their crystalline structure, forming 20-40 nm flower-like aggregates with a hydrodynamic diameter of 110-120 nm. The MNPs form stable (>12 months) colloidal solutions in water and exhibit no hysteresis under an applied quasistatic magnetic field, and produce a significant amount of heat at field strengths as low as 100 Oe at 99-164 kHz. The MNP heating mechanisms under an alternating magnetic field (AMF) are discussed and analyzed quantitatively based on (a) the calculated multi-scale MNP interactions obtained using a three dimensional numerical model called the method of auxiliary sources, (b) measured MNP frequency spectra, and (c) quantified MNP friction losses based on magneto-viscous theory. The frequency responses and hysteresis curves of the Dartmouth MNPs are measured and compared to the modeled data. The specific absorption rate of the particles is measured at various AMF strengths and frequencies, and compared to commercially available MNPs. The comparisons demonstrate the superior heating properties of the Dartmouth MNPs at low field strengths (<250 Oe). This may extend MNP hyperthermia therapy to deeper tumors that were previously non-viable targets, potentially enabling the treatment of some of the most difficult cancers, such as pancreatic and rectal cancers, without damaging normal tissue.

  12. Measuring attention using the Posner cuing paradigm: the role of across and within trial target probabilities

    PubMed Central

    Hayward, Dana A.; Ristic, Jelena

    2013-01-01

    Numerous studies conducted within the recent decades have utilized the Posner cuing paradigm for eliciting, measuring, and theoretically characterizing attentional orienting. However, the data from recent studies suggest that the Posner cuing task might not provide an unambiguous measure of attention, as reflexive spatial orienting has been found to interact with extraneous processes engaged by the task's typical structure, i.e., the probability of target presence across trials, which affects tonic alertness, and the probability of target presence within trials, which affects voluntary temporal preparation. To understand the contribution of each of these two processes to the measurement of attentional orienting we assessed their individual and combined effects on reflexive attention elicited by a spatially nonpredictive peripheral cue. Our results revealed that the magnitude of spatial orienting was modulated by joint changes in the global probability of target presence across trials and the local probability of target presence within trials, while the time course of spatial orienting was susceptible to changes in the probability of target presence across trials. These data thus raise important questions about the choice of task parameters within the Posner cuing paradigm and their role in both the measurement and theoretical attributions of the observed attentional effects. PMID:23730280

  13. Normative data for hand grip strength and key pinch strength, stratified by age and gender for a multiethnic Asian population.

    PubMed

    Lam, Ngee Wei; Goh, Hui Ting; Kamaruzzaman, Shahrul Bahyah; Chin, Ai-Vyrn; Poi, Philip Jun Hua; Tan, Maw Pin

    2016-10-01

    Hand strength is a good indicator of physical fitness and frailty among the elderly. However, there are no published hand strength references for Malaysians aged > 65 years. This study aimed to establish normative data for hand grip strength (HGS) and key pinch strength (KPS) for Malaysians aged ≥ 60 years, and explore the relationship between hand strength and physical ability. Healthy participants aged ≥ 60 years with no neurological conditions were recruited from rural and urban locations in Malaysia. HGS and KPS were measured using hand grip and key pinch dynamometers. Basic demographic data, anthropometric measures, modified Barthel Index scores and results of the Functional Reach Test (FRT), Timed Up and Go (TUG) test and Jebsen-Taylor Hand Function Test (JTHFT) were recorded. 362 subjects aged 60-93 years were recruited. The men were significantly stronger than the women in both HGS and KPS (p < 0.001). The hand strength of the study cohort was lower than that of elderly Western populations. Significant correlations were observed between hand strength, and residential area (p < 0.001), FRT (r = 0.236, p = 0.028), TUG (r = -0.227, p = 0.009) and JTHFT (r = -0.927, p < 0.001). This study established reference ranges for the HGS and KPS of rural and urban elderly Malaysian subpopulations. These will aid the use of hand strength as a screening tool for frailty among elderly persons in Malaysia. Future studies are required to determine the modifiable factors for poor hand strength. Copyright: © Singapore Medical Association

  14. Normative data for hand grip strength and key pinch strength, stratified by age and gender for a multiethnic Asian population

    PubMed Central

    Lam, Ngee Wei; Goh, Hui Ting; Kamaruzzaman, Shahrul Bahyah; Chin, Ai-Vyrn; Poi, Philip Jun Hua; Tan, Maw Pin

    2016-01-01

    INTRODUCTION Hand strength is a good indicator of physical fitness and frailty among the elderly. However, there are no published hand strength references for Malaysians aged > 65 years. This study aimed to establish normative data for hand grip strength (HGS) and key pinch strength (KPS) for Malaysians aged ≥ 60 years, and explore the relationship between hand strength and physical ability. METHODS Healthy participants aged ≥ 60 years with no neurological conditions were recruited from rural and urban locations in Malaysia. HGS and KPS were measured using hand grip and key pinch dynamometers. Basic demographic data, anthropometric measures, modified Barthel Index scores and results of the Functional Reach Test (FRT), Timed Up and Go (TUG) test and Jebsen-Taylor Hand Function Test (JTHFT) were recorded. RESULTS 362 subjects aged 60–93 years were recruited. The men were significantly stronger than the women in both HGS and KPS (p < 0.001). The hand strength of the study cohort was lower than that of elderly Western populations. Significant correlations were observed between hand strength, and residential area (p < 0.001), FRT (r = 0.236, p = 0.028), TUG (r = −0.227, p = 0.009) and JTHFT (r = −0.927, p < 0.001). CONCLUSION This study established reference ranges for the HGS and KPS of rural and urban elderly Malaysian subpopulations. These will aid the use of hand strength as a screening tool for frailty among elderly persons in Malaysia. Future studies are required to determine the modifiable factors for poor hand strength. PMID:26768064

  15. CADDIS Volume 2. Sources, Stressors and Responses: Ionic Strength - Simple Conceptual Diagram

    EPA Pesticide Factsheets

    Introduction to the ionic strength module, when to list ionic strength as a candidate cause, ways to measure ionic strength, simple and detailed conceptual diagrams for ionic strength, ionic strength module references and literature reviews.

  16. CADDIS Volume 2. Sources, Stressors and Responses: Ionic Strength - Detailed Conceptual Diagram

    EPA Pesticide Factsheets

    Introduction to the ionic strength module, when to list ionic strength as a candidate cause, ways to measure ionic strength, simple and detailed conceptual diagrams for ionic strength, ionic strength module references and literature reviews.

  17. Vertebral body bone strength: the contribution of individual trabecular element morphology.

    PubMed

    Parkinson, I H; Badiei, A; Stauber, M; Codrington, J; Müller, R; Fazzalari, N L

    2012-07-01

    Although the amount of bone explains the largest amount of variability in bone strength, there is still a significant proportion unaccounted for. The morphology of individual bone trabeculae explains a further proportion of the variability in bone strength and bone elements that contribute to bone strength depending on the direction of loading. Micro-CT imaging enables measurement of bone microarchitecture and subsequently mechanical strength of the same sample. It is possible using micro-CT data to perform morphometric analysis on individual rod and plate bone trabeculae using a volumetric spatial decomposition algorithm and hence determine their contribution to bone strength. Twelve pairs of vertebral bodies (T12/L1 or L4/L5) were harvested from human cadavers, and bone cubes (10 × 10 × 10 mm) were obtained. After micro-CT imaging, a volumetric spatial decomposition algorithm was applied, and measures of individual trabecular elements were obtained. Bone strength was measured in compression, where one bone specimen from each vertebral segment was tested supero-inferiorly (SI) and the paired specimen was tested antero-posteriorly (AP). Bone volume fraction was the strongest individual determinant of SI strength (r(2) = 0.77, p < 0.0001) and AP (r(2) = 0.54, p < 0.0001). The determination of SI strength was improved to r(2) = 0.87 with the addition of mean rod length and relative plate bone volume fraction. The determination of AP strength was improved to r(2) = 0.85 with the addition of mean rod volume and relative rod bone volume fraction. Microarchitectural measures of individual trabeculae that contribute to bone strength have been identified. In addition to the contribution of BV/TV, trabecular rod morphology increased the determination of AP strength by 57%, whereas measures of trabecular plate and rod morphology increased determination of SI strength by 13%. Decomposing vertebral body bone architecture into its constituent

  18. Origin of discrepancies between crater size-frequency distributions of coeval lunar geologic units via target property contrasts

    NASA Astrophysics Data System (ADS)

    van der Bogert, C. H.; Hiesinger, H.; Dundas, C. M.; Krüger, T.; McEwen, A. S.; Zanetti, M.; Robinson, M. S.

    2017-12-01

    Recent work on dating Copernican-aged craters, using Lunar Reconnaissance Orbiter (LRO) Camera data, re-encountered a curious discrepancy in crater size-frequency distribution (CSFD) measurements that was observed, but not understood, during the Apollo era. For example, at Tycho, Copernicus, and Aristarchus craters, CSFDs of impact melt deposits give significantly younger relative and absolute model ages (AMAs) than impact ejecta blankets, although these two units formed during one impact event, and would ideally yield coeval ages at the resolution of the CSFD technique. We investigated the effects of contrasting target properties on CSFDs and their resultant relative and absolute model ages for coeval lunar impact melt and ejecta units. We counted craters with diameters through the transition from strength- to gravity-scaling on two large impact melt deposits at Tycho and King craters, and we used pi-group scaling calculations to model the effects of differing target properties on final crater diameters for five different theoretical lunar targets. The new CSFD for the large King Crater melt pond bridges the gap between the discrepant CSFDs within a single geologic unit. Thus, the observed trends in the impact melt CSFDs support the occurrence of target property effects, rather than self-secondary and/or field secondary contamination. The CSFDs generated from the pi-group scaling calculations show that targets with higher density and effective strength yield smaller crater diameters than weaker targets, such that the relative ages of the former are lower relative to the latter. Consequently, coeval impact melt and ejecta units will have discrepant apparent ages. Target property differences also affect the resulting slope of the CSFD, with stronger targets exhibiting shallower slopes, so that the final crater diameters may differ more greatly at smaller diameters. Besides their application to age dating, the CSFDs may provide additional information about the

  19. Origin of discrepancies between crater size-frequency distributions of coeval lunar geologic units via target property contrasts

    USGS Publications Warehouse

    Van der Bogert, Carolyn H.; Hiesinger, Harald; Dundas, Colin M.; Kruger, T.; McEwen, Alfred S.; Zanetti, Michael; Robinson, Mark S.

    2017-01-01

    Recent work on dating Copernican-aged craters, using Lunar Reconnaissance Orbiter (LRO) Camera data, re-encountered a curious discrepancy in crater size-frequency distribution (CSFD) measurements that was observed, but not understood, during the Apollo era. For example, at Tycho, Copernicus, and Aristarchus craters, CSFDs of impact melt deposits give significantly younger relative and absolute model ages (AMAs) than impact ejecta blankets, although these two units formed during one impact event, and would ideally yield coeval ages at the resolution of the CSFD technique. We investigated the effects of contrasting target properties on CSFDs and their resultant relative and absolute model ages for coeval lunar impact melt and ejecta units. We counted craters with diameters through the transition from strength- to gravity-scaling on two large impact melt deposits at Tycho and King craters, and we used pi-group scaling calculations to model the effects of differing target properties on final crater diameters for five different theoretical lunar targets. The new CSFD for the large King Crater melt pond bridges the gap between the discrepant CSFDs within a single geologic unit. Thus, the observed trends in the impact melt CSFDs support the occurrence of target property effects, rather than self-secondary and/or field secondary contamination. The CSFDs generated from the pi-group scaling calculations show that targets with higher density and effective strength yield smaller crater diameters than weaker targets, such that the relative ages of the former are lower relative to the latter. Consequently, coeval impact melt and ejecta units will have discrepant apparent ages. Target property differences also affect the resulting slope of the CSFD, with stronger targets exhibiting shallower slopes, so that the final crater diameters may differ more greatly at smaller diameters. Besides their application to age dating, the CSFDs may provide additional information about the

  20. The Effects of Isolated and Integrated ‘Core Stability’ Training on Athletic Performance Measures

    PubMed Central

    Reed, Casey A.; Ford, Kevin R.; Myer, Gregory D.; Hewett, Timothy E.

    2014-01-01

    Background Core stability training, operationally defined as training focused to improve trunk and hip control, is an integral part of athletic development, yet little is known about its direct relation to athletic performance. Objective This systematic review focuses on identification of the association between core stability and sports-related performance measures. A secondary objective was to identify difficulties encountered when trying to train core stability with the goal of improving athletic performance. Data sources A systematic search was employed to capture all articles related to athletic performance and core stability training that were identified using the electronic databases MEDLINE, CINAHL and SPORTDiscus™ (1982-June2011). Study selection A systematic approach was used to evaluate 179 articles identified for initial review. Studies that performed an intervention targeted toward the core and measured an outcome related to athletic or sport performances were included, while studies with a participant population aged 65 years or older were excluded. Twenty-four in total met the inclusionary criteria for review. Study appraisal and synthesis methods Studies were evaluated using the Physical Therapy Evidence Database (PEDro) scale. The 24 articles were separated into three groups, general performance (n = 8), lower extremity (n = 10) and upper extremity (n = 6), for ease of discussion. Results In the majority of studies, core stability training was utilized in conjunction with more comprehensive exercise programmes. As such, many studies saw improvements in skills of general strengths such as maximum squat load and vertical leap. Surprisingly, not all studies reported measurable increases in specific core strength and stability measures following training. Additionally, investigations that targeted the core as the primary goal for improved outcome of training had mixed results. Limitations Core stability is rarely the sole component of an athletic

  1. Adaptive early detection ML/PDA estimator for LO targets with EO sensors

    NASA Astrophysics Data System (ADS)

    Chummun, Muhammad R.; Kirubarajan, Thiagalingam; Bar-Shalom, Yaakov

    2000-07-01

    The batch Maximum Likelihood Estimator, combined with Probabilistic Data (ML-PDA), has been shown to be effective in acquiring low observable (LO) - low SNR - non-maneuvering targets in the presence of heavy clutter. The use of signal strength or amplitude information (AI) in the ML-PDA estimator with AI in a sliding-window fashion, to detect high- speed targets in heavy clutter using electro-optical (EO) sensors. The initial time and the length of the sliding-window are adjusted adaptively according to the information content of the received measurements. A track validation scheme via hypothesis testing is developed to confirm the estimated track, that is, the presence of a target, in each window. The sliding-window ML-PDA approach, together with track validation, enables early detection by rejecting noninformative scans, target reacquisition in case of temporary target disappearance and the handling of targets with speeds evolving over time. The proposed algorithm is shown to detect the target, which is hidden in as many as 600 false alarms per scan, 10 frames earlier than the Multiple Hypothesis Tracking (MHT) algorithm.

  2. Alternative method of quantum state tomography toward a typical target via a weak-value measurement

    NASA Astrophysics Data System (ADS)

    Chen, Xi; Dai, Hong-Yi; Yang, Le; Zhang, Ming

    2018-03-01

    There is usually a limitation of weak interaction on the application of weak-value measurement. This limitation dominates the performance of the quantum state tomography toward a typical target in the finite and high-dimensional complex-valued superposition of its basis states, especially when the compressive sensing technique is also employed. Here we propose an alternative method of quantum state tomography, presented as a general model, toward such typical target via weak-value measurement to overcome such limitation. In this model the pointer for the weak-value measurement is a qubit, and the target-pointer coupling interaction is no longer needed within the weak interaction limitation, meanwhile this interaction under the compressive sensing can be described with the Taylor series of the unitary evolution operator. The postselection state at the target is the equal superposition of all basis states, and the pointer readouts are gathered under multiple Pauli operator measurements. The reconstructed quantum state is generated from an optimization algorithm of total variation augmented Lagrangian alternating direction algorithm. Furthermore, we demonstrate an example of this general model for the quantum state tomography toward the planar laser-energy distribution and discuss the relations among some parameters at both our general model and the original first-order approximate model for this tomography.

  3. Strength Asymmetry of the Shoulders in Elite Volleyball Players

    PubMed Central

    Hadzic, Vedran; Sattler, Tine; Veselko, Matjaž; Markovic, Goran; Dervisevic, Edvin

    2014-01-01

    Context: Volleyball players are reported to have shoulder strength imbalances. Previous authors have primarily investigated small samples of male players at a single skill level, without considering playing position, and with inconsistent findings. Objective: To evaluate shoulder strength asymmetry and a history of shoulder injury in a large sample of professional volleyball players of both sexes across different playing positions and skill levels. Design: Descriptive laboratory study. Patients or Other Participants: A sample of 183 volleyball players (99 men, 84 women). Main Outcome Measure(s): We assessed shoulder internal-rotator and external-rotator concentric strength at 60°/s using an isokinetic dynamometer and dominant-nondominant differences in shoulder strength and strength ratios using repeated-measures analyses of variance. Peak torque was normalized for body mass and external-rotation/internal-rotation concentric strength. Results: Internal-rotation strength was asymmetric in favor of the dominant side in both sexes, regardless of previous shoulder injury status. Male volleyball players had a lower shoulder strength ratio on the dominant side, regardless of previous shoulder injury status. However, this finding was valid only when hand dominance was taken into account. Female volleyball players playing at a higher level (ie, first versus second division) were 3.43 times more likely to have an abnormal strength ratio. Playing position was not associated with an abnormal shoulder strength ratio or strength asymmetry. Conclusions: In male volleyball players, the external-rotation/internal-rotation strength ratio of the dominant shoulder was lower, regardless of playing position, skill level, or a previous shoulder injury. In female players, the ratio was less only in those at a higher skill level. Although speculative, these findings generally suggest that female volleyball players could have a lower risk of developing shoulder-related problems than male

  4. Lower limb strength training in children with cerebral palsy – a randomized controlled trial protocol for functional strength training based on progressive resistance exercise principles

    PubMed Central

    Scholtes, Vanessa A; Dallmeijer, Annet J; Rameckers, Eugene A; Verschuren, Olaf; Tempelaars, Els; Hensen, Maartje; Becher, Jules G

    2008-01-01

    Background Until recently, strength training in children with cerebral palsy (CP) was considered to be inappropriate, because it could lead to increased spasticity or abnormal movement patterns. However, the results of recent studies suggest that progressive strength training can lead to increased strength and improved function, but low methodological quality and incomplete reporting on the training protocols hampers adequate interpretation of the results. This paper describes the design and training protocol of a randomized controlled trial to assess the effects of a school-based progressive functional strength training program for children with CP. Methods/Results Fifty-one children with Gross Motor Function Classification Systems levels I to III, aged of 6 to 13 years, were recruited. Using stratified randomization, each child was assigned to an intervention group (strength training) or a control group (usual care). The strength training was given in groups of 4–5 children, 3 times a week, for a period of 12 weeks. Each training session focussed on four exercises out of a 5-exercise circuit. The training load was gradually increased based on the child's maximum level of strength, as determined by the 8 Repetition Maximum (8 RM). To evaluate the effectiveness of the training, all children were evaluated before, during, directly after, and 6 weeks after the intervention period. Primary outcomes in this study were gross motor function (measured with the Gross Motor Function Measure and functional muscle strength tests) and walking ability (measured with the 10-meter, the 1-minute and the timed stair test). Secondary outcomes were lower limb muscle strength (measured with a 6 RM test, isometric strength tests, and a sprint capacity test), mobility (measured with a mobility questionnaire), and sport activities (measured with the Children's Assessment of Participation and Enjoyment). Spasticity and range of motion were assessed to evaluate any adverse events

  5. Positive Psychology and Character Strengths: Application to Strengths-Based School Counseling

    ERIC Educational Resources Information Center

    Park, Nansook; Peterson, Christopher

    2008-01-01

    The basic premise of positive psychology is that the happiness and fulfillment of children and youth entail more than the identification and treatment of their problems. This article provides an overview of positive psychology and the Values in Action (VIA) project that classifies and measures 24 widely recognized character strengths. Good…

  6. Measurement invariance of the strength of motivation for medical school: a multi-group confirmatory factor analysis.

    PubMed

    An, M; Kusurkar, R A; Li, L; Xiao, Y; Zheng, C; Hu, J; Chen, M

    2017-07-11

    The Strength of Motivation for Medical School-Revised (SMMS-R) questionnaire measures students' motivation for studying medicine. It includes three subscales: 'willingness to sacrifice', 'readiness to start', and 'persistence'. Measurement invariance is a prerequisite for group comparisons. The objectives of this study were to verify the factorial structure of the SMMS-R questionnaire and to investigate it's measurement invariance. A total of 989 medical students were approached, 930 cases were kept for data analysis. Factorial structure of and measurement invariance of the SMMS-R were tested using single and multiple group confirmatory factor analyses with Mplus. Trational Cronbach's α along with McDonald's ω and glb were used to measure internal consistency for each subscale. Internal consistency for subscales and the full instrument were within the acceptable range. A 3-factor structure of the Chinese version of the SMMS-R was supported. Full configural, metric and partial scalar invariance were obtained. The SMMS-R showed measurement invariance across gender and two independent samples. So it can be used for group and cross-cultural comparisons.

  7. The Relationship among Leg Strength, Leg Power and Alpine Skiing Success.

    ERIC Educational Resources Information Center

    Gettman, Larry R.; Huckel, Jack R.

    The purpose of this study was to relate leg strength and power to alpine skiing success as measured by FIS points. Isometric leg strength was represented by the knee extension test described by Clarke. Leg power was measured by the vertical jump test and the Margaria-Kalamen stair run. Results in the strength and power tests were correlated with…

  8. Isometric elbow extensors strength in supine- and prone-lying positions.

    PubMed

    Abdelzaher, Ibrahim E; Ababneh, Anas F; Alzyoud, Jehad M

    2013-01-01

    The purpose of this study was to compare isometric strength of elbow extensors measured in supine- and prone-lying positions at elbow flexion angles of 45 and 90 degrees. Twenty-two male subjects under single-blind procedures participated in the study. Each subject participated in both supine-lying and prone-lying measuring protocols. Calibrated cable tensiometer was used to measure isometric strength of the right elbow extensors and a biofeedback electromyography was used to assure no substitution movements from shoulder girdle muscles. The mean values of isometric strength of elbow extensors measured from supine-lying position at elbow flexion angles of 45 and 90 degrees were 11.1  ±  4.2 kg and 13.1  ±  4.6 kg, while those measured from prone-lying position were 9.9  ±  3.6 kg and 12  ±  4.2 kg, respectively. There is statistical significant difference between the isometric strength of elbow extensors measured from supine-lying position at elbow flexion angles of 45 and 90 degrees compared to that measured from prone-lying position (p  <  0.05). The results suggest that in manual muscle testing starting position can affect the isometric strength of elbow extensors since supine-lying starting position is better than prone-lying starting position.

  9. Design, construction and performance evaluation of the target tissue thickness measurement system in intraoperative radiotherapy for breast cancer

    NASA Astrophysics Data System (ADS)

    Yazdani, Mohammad Reza; Setayeshi, Saeed; Arabalibeik, Hossein; Akbari, Mohammad Esmaeil

    2017-05-01

    Intraoperative electron radiation therapy (IOERT), which uses electron beams for irradiating the target directly during the surgery, has the advantage of delivering a homogeneous dose to a controlled layer of tissue. Since the dose falls off quickly below the target thickness, the underlying normal tissues are spared. In selecting the appropriate electron energy, the accuracy of the target tissue thickness measurement is critical. In contrast to other procedures applied in IOERT, the routine measurement method is considered to be completely traditional and approximate. In this work, a novel mechanism is proposed for measuring the target tissue thickness with an acceptable level of accuracy. An electronic system has been designed and manufactured with the capability of measuring the tissue thickness based on the recorded electron density under the target. The results indicated the possibility of thickness measurement with a maximum error of 2 mm for 91.35% of data. Aside from system limitation in estimating the thickness of 5 mm phantom, for 88.94% of data, maximum error is 1 mm.

  10. Male facial appearance signals physical strength to women.

    PubMed

    Fink, Bernhard; Neave, Nick; Seydel, Hanna

    2007-01-01

    Previous studies showed that male faces with extreme features that are likely to be associated with testosterone (T) are perceived as dominant and masculine. Women were reported to prefer masculinized male faces, as they may consider T markers to be an "honest" indication of good health. However, it is also likely that female preferences for certain male faces arise from the fact that dominant- and masculine-looking males are signaling characteristics which may be beneficial in intrasexual conflict, and thereby also indicate potential achievers of high status, an important factor in female mate selection. Although numerous studies were built on this assumption, nothing is known about the relationship between perceived facial dominance and physical strength in men. We measured hand-grip strength, as a measure of overall physical strength, in a sample of 32 male students, and recorded age, body weight, and height. Seventy-nine women rated facial images of these men for dominance, masculinity, and attractiveness. After controlling for age and body weight, hand-grip strength was found to correlate significantly positively with all three measures. The present data thus support the supposition that a male's physical strength is also signaled via facial characteristics of dominance and masculinity, which are considered attractive by women.

  11. Strength training improves the tri-digit finger-pinch force control of older adults.

    PubMed

    Keogh, Justin W; Morrison, Steve; Barrett, Rod

    2007-08-01

    To investigate the effect of unilateral upper-limb strength training on the finger-pinch force control of older men. Pretest and post-test 6-week intervention study. Exercise science research laboratory. Eleven neurologically fit older men (age range, 70-80y). The strength training group (n=7) trained twice a week for 6 weeks, performing dumbbell bicep curls, wrist flexions, and wrists extensions, while the control group subjects (n=4) maintained their normal activities. Changes in force variability, targeting error, peak power frequency, proportional power, sample entropy, digit force sharing, and coupling relations were assessed during a series of finger-pinch tasks. These tasks involved maintaining a constant or sinusoidal force output at 20% and 40% of each subject's maximum voluntary contraction. All participants performed the finger-pinch tasks with both the preferred and nonpreferred limbs. Analysis of covariance for between-group change scores indicated that the strength training group (trained limb) experienced significantly greater reductions in finger-pinch force variability and targeting error, as well as significantly greater increases in finger-pinch force, sample entropy, bicep curl, and wrist flexion strength than did the control group. A nonspecific upper-limb strength-training program may improve the finger-pinch force control of older men.

  12. Scale effects on the transverse tensile strength of graphite epoxy composites

    NASA Technical Reports Server (NTRS)

    Obrien, T. Kevin; Salpekar, Satish A.

    1992-01-01

    The influence of material volume on the transverse tensile strength of AS4/3501-6 graphite epoxy composites was investigated. Tensile tests of 90 degree laminates with 3 different widths and 5 different thicknesses were conducted. A finite element analysis was performed to determine the influence of the grip on the stress distribution in the coupons and explain the tendency for the distribution of failure locations to be skewed toward the grip. Specimens were instrumented with strain gages and extensometers to insure good alignment and to measure failure strains. Data indicated that matrix dominated strength properties varied with the volume of material that was stressed, with the strength decreasing as volume increased. Transverse strength data were used in a volumetric scaling law based on Weibull statistics to predict the strength of 90 degree laminates loaded in three point bending. Comparisons were also made between transverse strength measurements and out-of-plane interlaminar tensile strength measurements from curved beam bending tests. The significance of observed scale effects on the use of tests for material screening, quality assurance, and design allowables is discussed.

  13. Pulmonary Function, Muscle Strength, and Incident Mobility Disability in Elders

    PubMed Central

    Buchman, Aron S.; Boyle, Patricia A.; Leurgans, Sue E.; Evans, Denis A.; Bennett, David A.

    2009-01-01

    Muscle strength, including leg strength and respiratory muscle strength, are relatively independently associated with mobility disability in elders. However, the factors linking muscle strength with mobility disability are unknown. To test the hypothesis that pulmonary function mediates the association of muscle strength with the development of mobility disability in elders, we used data from a longitudinal cohort study of 844 ambulatory elders without dementia participating in the Rush Memory and Aging Project with a mean follow-up of 4.0 years (SD = 1.39). A composite measure of pulmonary function was based on spirometric measures of forced vital capacity, forced expiratory volume, and peak expiratory flow. Respiratory muscle strength was based on maximal inspiratory pressure and expiratory pressure and leg strength based on hand-held dynamometry. Mobility disability was defined as a gait speed less than or equal to 0.55 m/s based on annual assessment of timed walk. Secondary analyses considered time to loss of the ability to ambulate. In separate proportional hazards models which controlled for age, sex, and education, composite measures of pulmonary function, respiratory muscle strength, and leg strength were each associated with incident mobility disability (all P values < 0.001). Further, all three were related to the development of incident mobility disability when considered together in a single model (pulmonary function: hazard ratio [HR], 0.721; 95% confidence interval [CI], 0.577, 0.902; respiratory muscle strength: HR, 0.732; 95% CI, 0.593, 0.905; leg strength: HR, 0.791; 95% CI, 0.640, 0.976). Secondary analyses examining incident loss of the ability to ambulate revealed similar findings. Overall, these findings suggest that lower levels of pulmonary function and muscle strength are relatively independently associated with the development of mobility disability in the elderly. PMID:19934353

  14. Measurement of multiaxial ply strength by an off-axis flexure test

    NASA Technical Reports Server (NTRS)

    Crews, John H., Jr.; Naik, Rajiv A.

    1992-01-01

    An off-axis flexure (OAF) test was performed to measure ply strength under multiaxial stress states. This test involves unidirectional off-axis specimens loaded in bending, using an apparatus that allows these anisotropic specimens to twist as well as flex without the complications of a resisting torque. A 3D finite element stress analysis verified that simple beam theory could be used to compute the specimen bending stresses at failure. Unidirectional graphite/epoxy specimens with fiber angles ranging from 90 deg to 15 deg have combined normal and shear stresses on their failure planes that are typical of 45 deg plies in structural laminates. Tests for a range of stress states with AS4/3501-6 specimens showed that both normal and shear stresses on the failure plane influenced cracking resistance. This OAF test may prove to be useful for generating data needed to predict ply cracking in composite structures and may also provide an approach for studying fiber-matrix interface failures under stress states typical of structures.

  15. Measurements of a Strength of Metals in a Picosecond Time Range

    NASA Astrophysics Data System (ADS)

    Ashitkov, Sergey; Komarov, Pavel; Agranat, Mikhail; Kanel, Gennady; Fortov, Vladimir

    2013-06-01

    We studied the shock-wave phenomena in metal films of a micron or submicron thickness irradiated by femtosecond laser pulses. The single-shot interferometer technique was used to record the time and spatial resolved displacements of both the frontal and rear surfaces of the films. The free surface displacement histories were converted into the free surface velocity histories using several various approaches. As a result, new data on the HEL and spall strength values have been obtained for aluminum, iron, nickel and other metals in strongly metastable states close to ultimate shear and tensile stresses. Comparison of measured parameters of elastic shock waves with the data of plate impact experiments at larger sample thicknesses demonstrate different regimes of the decay: whereas for pure fcc metals the decay may be described by one power function over 1 μm to 10 mm range of the distances, in the case of bcc iron main decay occurs obviously at the distance of order of 50 μm. The data are discussed from the view point of main mechanisms of high-rate deformation and fracture.

  16. Rock strength measurements on Archaean basement granitoids recovered from scientific drilling in the active Koyna seismogenic zone, western India

    NASA Astrophysics Data System (ADS)

    Goswami, Deepjyoti; Akkiraju, Vyasulu V.; Misra, Surajit; Roy, Sukanta; Singh, Santosh K.; Sinha, Amalendu; Gupta, Harsh; Bansal, B. K.; Nayak, Shailesh

    2017-08-01

    Reservoir triggered earthquakes have been occurring in the Koyna area, western India for the past five decades. Triaxial tests carried out on 181 core samples of Archaean granitoids underlying the Deccan Traps provide valuable constraints on rock strength properties in the Koyna seismogenic zone for the first time. The data include measurements on granite gneiss, granite, migmatitic gneiss and mylonitised granite gneiss obtained from boreholes KBH-3, KBH-4A, KBH-5 and KBH-7 located in the western and eastern margins of the seismic zone. Salient results are as follows. (i) Increase of rock strength with increasing confining pressure allow determination of the linearized failure envelopes from which the cohesive strength and angle of internal friction are calculated. (ii) Variable differential stresses at different depths are the manifestations of deformation partitioning in close association of fault zone(s) or localized fracture zones. (iii) Fractures controlled by naturally developed weak planes such as cleavage and fabric directly affect the rock strength properties, but the majority of failure planes developed during triaxial tests is not consistent with the orientations of pre-existing weak planes. The failure planes may, therefore, represent other planes of weakness induced by ongoing seismic activity. (iv) Stress-strain curves confirm that axial deformation is controlled by the varying intensity of pre-existing shear in the granitoids, viz., mylonite, granite gneiss and migmatitic gneiss. (v) Frequent occurrences of low magnitude earthquakes may be attributed to low and variable rock strength of the granitoids, which, in turn, is modified by successive seismic events.

  17. Greater understanding of normal hip physical function may guide clinicians in providing targeted rehabilitation programmes.

    PubMed

    Kemp, Joanne L; Schache, Anthony G; Makdissi, Michael; Sims, Kevin J; Crossley, Kay M

    2013-07-01

    This study investigated tests of hip muscle strength and functional performance. The specific objectives were to: (i) establish intra- and inter-rater reliability; (ii) compare differences between dominant and non-dominant limbs; (iii) compare agonist and antagonist muscle strength ratios; (iv) compare differences between genders; and (v) examine relationships between hip muscle strength, baseline measures and functional performance. Reliability study and cross-sectional analysis of hip strength and functional performance. In healthy adults aged 18-50years, normalised hip muscle peak torque and functional performance were evaluated to: (i) establish intra-rater and inter-rater reliability; (ii) analyse differences between limbs, between antagonistic muscle groups and genders; and (iii) associations between strength and functional performance. Excellent reliability (intra-rater ICC=0.77-0.96; inter-rater ICC=0.82-0.95) was observed. No difference existed between dominant and non-dominant limbs. Differences in strength existed between antagonistic pairs of muscles: hip abduction was greater than adduction (p<0.001) and hip ER was greater than IR (p<0.001). Men had greater ER strength (p=0.006) and hop for distance (p<0.001) than women. Strong associations were observed between measures of hip muscle strength (except hip flexion) and age, height, and functional performance. Deficits in hip muscle strength or functional performance may influence hip pain. In order to provide targeted rehabilitation programmes to address patient-specific impairments, and determine when individuals are ready to return to physical activity, clinicians are increasingly utilising tests of hip strength and functional performance. This study provides a battery of reliable, clinically applicable tests which can be used for these purposes. Copyright © 2012 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  18. Looking at eye dominance from a different angle: is sighting strength related to hand preference?

    PubMed

    Carey, David P; Hutchinson, Claire V

    2013-10-01

    Sighting dominance (the behavioural preference for one eye over the other under monocular viewing conditions) has traditionally been thought of as a robust individual trait. However, Khan and Crawford (2001) have shown that, under certain viewing conditions, eye preference reverses as a function of horizontal gaze angle. Remarkably, the reversal of sighting from one eye to the other depends on which hand is used to reach out and grasp the target. Their procedure provides an ideal way to measure the strength of monocular preference for sighting, which may be related to other indicators of hemispheric specialisation for speech, language and motor function. Therefore, we hypothesised that individuals with consistent side preferences (e.g., right hand, right eye) should have more robust sighting dominance than those with crossed lateral preferences. To test this idea, we compared strength of eye dominance in individuals who are consistently right or left sided for hand and foot preference with those who are not. We also modified their procedure in order to minimise a potential image size confound, suggested by Banks et al. (2004) as an explanation of Khan and Crawford's results. We found that the sighting dominance switch occurred at similar eccentricities when we controlled for effects of hand occlusion and target size differences. We also found that sighting dominance thresholds change predictably with the hand used. However, we found no evidence for relationships between strength of hand preference as assessed by questionnaire or by pegboard performance and strength of sighting dominance. Similarly, participants with consistent hand and foot preferences did not show stronger eye preference as assessed using the Khan and Crawford procedure. These data are discussed in terms of indirect relationships between sighting dominance, hand preference and cerebral specialisation for language and motor control. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. A Feasibility Study of Nonlinear Spectroscopic Measurement of Magnetic Nanoparticles Targeted to Cancer Cells.

    PubMed

    Ficko, Bradley W; NDong, Christian; Giacometti, Paolo; Griswold, Karl E; Diamond, Solomon G

    2017-05-01

    Magnetic nanoparticles (MNPs) are an emerging platform for targeted diagnostics in cancer. An important component needed for translation of MNPs is the detection and quantification of targeted MNPs bound to tumor cells. This study explores the feasibility of a multifrequency nonlinear magnetic spectroscopic method that uses excitation and pickup coils and is capable of discriminating between quantities of bound and unbound MNPs in 0.5 ml samples of KB and Igrov human cancer cell lines. The method is tested over a range of five concentrations of MNPs from 0 to 80 μg/ml and five concentrations of cells from 50 to 400 000 count per ml. A linear model applied to the magnetic spectroscopy data was able to simultaneously measure bound and unbound MNPs with agreement between the model-fit and lab assay measurements (p < 0.001). The detectable iron of the presented method to bound and unbound MNPs was < 2 μg in a 0.5 ml sample. The linear model parameters used to determine the quantities of bound and unbound nanoparticles in KB cells were also used to measure the bound and unbound MNP in the Igrov cell line and vice versa. Nonlinear spectroscopic measurement of MNPs may be a useful method for studying targeted MNPs in oncology. Determining the quantity of bound and unbound MNP in an unknown sample using a linear model represents an exciting opportunity to translate multifrequency nonlinear spectroscopy methods to in vivo applications where MNPs could be targeted to cancer cells.

  20. Complementary Approaches to Existing Target Based Drug Discovery for Identifying Novel Drug Targets.

    PubMed

    Vasaikar, Suhas; Bhatia, Pooja; Bhatia, Partap G; Chu Yaiw, Koon

    2016-11-21

    In the past decade, it was observed that the relationship between the emerging New Molecular Entities and the quantum of R&D investment has not been favorable. There might be numerous reasons but few studies stress the introduction of target based drug discovery approach as one of the factors. Although a number of drugs have been developed with an emphasis on a single protein target, yet identification of valid target is complex. The approach focuses on an in vitro single target, which overlooks the complexity of cell and makes process of validation drug targets uncertain. Thus, it is imperative to search for alternatives rather than looking at success stories of target-based drug discovery. It would be beneficial if the drugs were developed to target multiple components. New approaches like reverse engineering and translational research need to take into account both system and target-based approach. This review evaluates the strengths and limitations of known drug discovery approaches and proposes alternative approaches for increasing efficiency against treatment.

  1. Lithium target performance evaluation for low-energy accelerator-based in vivo measurements using gamma spectroscopy.

    PubMed

    Aslam; Prestwich, W V; McNeill, F E

    2003-03-01

    The operating conditions at McMaster KN Van de Graaf accelerator have been optimized to produce neutrons via the (7)Li(p, n)(7)Be reaction for in vivo neutron activation analysis. In a number of earlier studies (development of an accelerator based system for in vivo neutron activation analysis measurements of manganese in humans, Ph.D. Thesis, McMaster University, Hamilton, ON, Canada; Appl. Radiat. Isot. 53 (2000) 657; in vivo measurement of some trace elements in human Bone, Ph.D. Thesis. McMaster University, Hamilton, ON, Canada), a significant discrepancy between the experimental and the calculated neutron doses has been pointed out. The hypotheses formulated in the above references to explain the deviation of the experimental results from analytical calculations, have been tested experimentally. The performance of the lithium target for neutron production has been evaluated by measuring the (7)Be activity produced as a result of (p, n) interaction with (7)Li. In contradiction to the formulated hypotheses, lithium target performance was found to be mainly affected by inefficient target cooling and the presence of oxides layer on target surface. An appropriate choice of these parameters resulted in neutron yields same as predicated by analytical calculations.

  2. Intrinsic bond strength of metal films on polymer substrates

    NASA Technical Reports Server (NTRS)

    Wheeler, Donald R.; Osaki, Hiroyuki

    1990-01-01

    A semiquantitative method for the measurement of the intrinsic bond strength between elastic substrates and elastic films that fail by brittle fracture is described. Measurements on a polyethylene terephthalate (PET)-Ni couple were used to verify the essential features of the analysis. It was found that the interfacial shear strength of Ni on PET doubled after ion etching.

  3. Objective evaluation of muscle strength in infants with hypotonia and muscle weakness.

    PubMed

    Reus, Linda; van Vlimmeren, Leo A; Staal, J Bart; Janssen, Anjo J W M; Otten, Barto J; Pelzer, Ben J; Nijhuis-van der Sanden, Maria W G

    2013-04-01

    The clinical evaluation of an infant with motor delay, muscle weakness, and/or hypotonia would improve considerably if muscle strength could be measured objectively and normal reference values were available. The authors developed a method to measure muscle strength in infants and tested 81 typically developing infants, 6-36 months of age, and 17 infants with Prader-Willi Syndrome (PWS) aged 24 months. The inter-rater reliability of the measurement method was good (ICC=.84) and the convergent validity was confirmed by high Pearson's correlations between muscle strength, age, height, and weight (r=.79-.85). A multiple linear regression model was developed to predict muscle strength based on age, height, and weight, explaining 73% of the variance in muscle strength. In infants with PWS, muscle strength was significantly decreased. Pearson's correlations showed that infants with PWS in which muscle strength was more severely affected also had a larger motor developmental delay (r=.75). Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Multi-Scale Effects in the Strength of Ceramics

    PubMed Central

    Cook, Robert F.

    2016-01-01

    Multiple length-scale effects are demonstrated in indentation-strength measurements of a range of ceramic materials under inert and reactive conditions. Meso-scale effects associated with flaw disruption by lateral cracking at large indentation loads are shown to increase strengths above the ideal indentation response. Micro-scale effects associated with toughening by microstructural restraints at small indentation loads are shown to decrease strengths below the ideal response. A combined meso-micro-scale analysis is developed that describes ceramic inert strength behaviors over the complete indentation flaw size range. Nano-scale effects associated with chemical equilibria and crack velocity thresholds are shown to lead to invariant minimum strengths at slow applied stressing rates under reactive conditions. A combined meso-micro-nano-scale analysis is developed that describes the full range of reactive and inert strength behaviors as a function of indentation load and applied stressing rate. Applications of the multi-scale analysis are demonstrated for materials design, materials selection, toughness determination, crack velocity determination, bond-rupture parameter determination, and prediction of reactive strengths. The measurements and analysis provide strong support for the existence of sharp crack tips in ceramics such that the nano-scale mechanisms of discrete bond rupture are separate from the larger scale crack driving force mechanics characterized by continuum-based stress-intensity factors. PMID:27563150

  5. Strength and cardiometabolic risk in young adults: The mediator role of aerobic fitness and waist circumference.

    PubMed

    Díez-Fernández, A; Martínez-Vizcaíno, V; Torres-Costoso, A; Cañete García-Prieto, J; Franquelo-Morales, P; Sánchez-López, M

    2018-07-01

    The aim of this study was to analyze the mediation role of cardiorespiratory fitness and waist circumference in the association between muscular strength and cardiometabolic risk. A cross-sectional study involved first-year college students (n = 370) from a Spanish public university was performed. We measured weight, height, waist circumference, blood pressure, biochemical variables, maximum handgrip strength assessment, and cardiorespiratory fitness. We calculated handgrip dynamometry/weight and a previously validated cardiometabolic risk index. Analysis of covariance models was conducted to test differences in cardiometabolic risk values across muscular strength, cardiorespiratory fitness, and waist circumference categories, controlling for confounders. Hayes' PROCESS macro was used for the multiple mediation analysis. The relationship between muscular strength and cardiometabolic risk did not remain significant (c' = 1.76 [1.4]; P > .05) in a multiple serial bootstrapped mediation model including cardiorespiratory fitness and waist circumference as mediators when controlling for age and sex. According to the indirect effect, the significant paths in the model mediating this relationship between muscular strength and cardiometabolic risk index were as follows: muscular strength → waist circumference → cardiometabolic risk index (-4.899; 95% CI: -6.690; -3.450) and muscular strength → cardiorespiratory fitness → waist circumference → cardiometabolic risk index (-0.720; 95% CI: -1.316; -0.360). Both cardiorespiratory fitness and waist circumference mediate the association between muscular strength and cardiometabolic risk in young adults. Thus, our results place cardiorespiratory fitness and waist circumference as the main targets of physical activity programmes aimed at preventing cardiometabolic diseases. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Impact strength of small icy bodies that experienced multiple collisions

    NASA Astrophysics Data System (ADS)

    Yasui, Minami; Hayama, Ryo; Arakawa, Masahiko

    2014-05-01

    Frequent collisions are common for small bodies in the Solar System, and the cumulative damage to these bodies is thought to significantly affect their evolution. It is important to study the effects of multiple impacts such as the number of impacts on the impact strength and the ejection velocity of impact fragments. Here we conducted multiple-impact experiments using a polycrystalline water ice target, varying the number of impacts from 1 to 10 times. An ice cylindrical projectile was impacted at 84-502 m s-1 by using a single-stage gas gun in a cold room between -10 and -15 °C. The impact strength of the ice target that experienced a single impact and multiple impacts is expressed by the total energy density applied to the same target, ΣQ, and this value was observed to be 77.6 J kg-1. The number of fine impact fragments at a fragment mass normalized by an initial target mass, m/Mt0 ∼ 10-6, nm, had a good correlation with the single energy density at each shot, Qj, and the relationship was shown to be nm=10·Qj1.31±0.12. We also estimated the cumulative damage of icy bodies as a total energy density accumulated by past impacts, according to the crater scaling laws proposed by Housen et al. (Housen, K.R., Schmidt, R.M., Holsapple, K.A. [1983]. J. Geophys. Res. 88, 2485-2499) of ice and the crater size distributions observed on Phoebe, a saturnian icy satellite. We found that the cumulative damage of Phoebe depended significantly on the impact speed of the impactor that formed the craters on Phoebe; and the cumulative damage was about one-third of the impact strength ΣQ* at 500 m s-1 whereas it was almost zero at 3.2 km s-1.

  7. Effective Collision Strengths for Fine-structure Transitions in Si VII

    NASA Astrophysics Data System (ADS)

    Sossah, A. M.; Tayal, S. S.

    2014-05-01

    The effective collision strengths for electron-impact excitation of fine-structure transitions in Si VII are calculated as a function of electron temperature in the range 5000-2,000,000 K. The B-spline Breit-Pauli R-matrix method has been used to calculate collision strengths by electron impact. The target wave functions have been obtained using the multi-configuration Hartree-Fock method with term-dependent non-orthogonal orbitals. The 92 fine-structure levels belonging to the 46 LS states of 2s 22p 4, 2s2p 5, 2p 6, 2s 22p 33s, 2s 22p 33p, 2s 22p 33d, and 2s2p 43s configurations are included in our calculations of oscillator strengths and collision strengths. There are 4186 possible fine-structure allowed and forbidden transitions among the 92 levels. The present excitation energies, oscillator strengths, and collision strengths have been compared with previous theoretical results and available experimental data. Generally, a good agreement is found with the 6 LS-state close-coupling approximation results of Butler & Zeippen and the 44 LS-state distorted wave calculation of Bhatia & Landi.

  8. Contribution of flexor pollicis longus to pinch strength: an in vivo study.

    PubMed

    Goetz, Thomas J; Costa, Joseph A; Slobogean, Gerard; Patel, Satyam; Mulpuri, Kishore; Travlos, Andrew

    2012-11-01

    To estimate the contribution of the flexor pollicis longus (FPL) to key pinch strength. Secondary outcomes include tip pinch, 3-point chuck pinch, and grip strength. Eleven healthy volunteers consented to participate in the study. We recorded baseline measures for key, 3-point chuck, and tip pinch and for grip strength. In order to control for instability of the interphalangeal (IP) joint after FPL paralysis, pinch measurements were repeated after immobilizing the thumb IP joint. Measures were repeated after subjects underwent electromyography-guided lidocaine blockade of the FPL muscle. Nerve conduction studies and clinical examinations were used to confirm FPL blockade and to rule out median nerve blockade. Paired t-tests were used to compare pre- and postblock means for both unsplinted and splinted measures. The difference in means was used to estimate the contribution of FPL to pinch strength. All 3 types of pinch strength showed a significant decrease between pre- and postblock measurements. The relative contribution of FPL for each pinch type was 56%, 44%, and 43% for key, chuck, and tip pinch, respectively. Mean grip strength did not decrease significantly. Splinting of the IP joint had no significant effect on pinch measurements. FPL paralysis resulted in a statistically significant decrease in pinch strength. IP joint immobilization to simulate IP joint fusion did not affect results. Reconstruction after acute or chronic loss of FPL function should be considered when restoration of pinch strength is important. Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  9. Method and apparatus for sensing a target characteristic by measuring both impedance and resonant frequency of a tank circuit

    NASA Technical Reports Server (NTRS)

    Laskowski, Edward L. (Inventor)

    1995-01-01

    An apparatus for sensing a target characteristic, such as relative distance between the apparatus and target, target thickness, target material, or lateral position between the apparatus and the target, includes a coil for directing an electro-magnetic field at the target. A voltage controlled oscillator energizes the coil at a resonant frequency which is functionally related to the target characteristic. The coil has an effective impedance value at resonance functionally related to the target characteristic. A frequency monitor measures the resonant frequency. An impedance monitor determines the impedance value when the drive frequency is at the resonant value. A PROM or controller determines the target characteristic in response to the measured resonant frequency and the determined impedance value. The PROM or controller provides a signal responsive to the determined target characteristic.

  10. The effect of changing the magnetic field strength on HiPIMS deposition rates

    NASA Astrophysics Data System (ADS)

    Bradley, J. W.; Mishra, A.; Kelly, P. J.

    2015-06-01

    The marked difference in behaviour between HiPIMS and conventional dc or pulsed-dc magnetron sputtering discharges with changing magnetic field strengths is demonstrated through measurements of deposition rate. To provide a comparison between techniques the same circular magnetron was operated in the three excitation modes at a fixed average power of 680 W and a pressure of 0.54 Pa in the non-reactive sputtering of titanium. The total magnetic field strength B at the cathode surface in the middle of the racetrack was varied from 195 to 380 G. DC and pulsed-dc discharges show the expected behaviour that deposition rates fall with decreasing B (here by ~25-40%), however the opposite trend is observed in HiPIMS with deposition rates rising by a factor of 2 over the same decrease in B. These observations are understood from the stand point of the different composition and transport processes of the depositing metal flux between the techniques. In HiPIMS, this flux is largely ionic and slow post-ionized sputtered particles are subject to strong back attraction to the target by a retarding plasma potential structure ahead of them. The height of this potential barrier is known to increase with increasing B. From a simple phenomenological model of the sputtered particles fluxes, and using the measured deposition rates from the different techniques as inputs, the combined probabilities of ionization, α, and back attraction, β, of the metal species in HiPIMS has been calculated. There is a clear fall in αβ (from ~0.9 to ~0.7) with decreasing B-field strengths, we argue primarily due to a weakening of electrostatic ion back attraction, so leading to higher deposition rates. The results indicate that careful design of magnetron field strengths should be considered to optimise HiPIMS deposition rates.

  11. Influence of lateral target size on hot electron production and electromagnetic pulse emission from laser-irradiated metallic targets

    NASA Astrophysics Data System (ADS)

    Chen, Zi-Yu; Li, Jian-Feng; Yu, Yong; Wang, Jia-Xiang; Li, Xiao-Ya; Peng, Qi-Xian; Zhu, Wen-Jun

    2012-11-01

    The influences of lateral target size on hot electron production and electromagnetic pulse emission from laser interaction with metallic targets have been investigated. Particle-in-cell simulations at high laser intensities show that the yield of hot electrons tends to increase with lateral target size, because the larger surface area reduces the electrostatic field on the target, owing to its expansion along the target surface. At lower laser intensities and longer time scales, experimental data characterizing electromagnetic pulse emission as a function of lateral target size also show target-size effects. Charge separation and a larger target tending to have a lower target potential have both been observed. The increase in radiation strength and downshift in radiation frequency with increasing lateral target size can be interpreted using a simple model of the electrical capacity of the target.

  12. Studying Hardness Meter Spring Strength to Understand Hardness Distribution on Body Surfaces.

    PubMed

    Arima, Yoshitaka

    2017-10-01

    For developing a hardness multipoint measurement system for understanding hardness distribution on biological body surfaces, we investigated the spring strength of the contact portion main axis of a biological tissue hardness meter (product name: PEK). We measured the hardness of three-layered sheets of six types of gel sheets (90 mm × 60 mm × 6 mm) constituting the acupuncture practice pads, with PEK measurements of 1.96 N, 2.94 N, 3.92 N, 4.90 N, 5.88 N, 6.86 N, 7.84 N, 8.82 N, and 9.81 N of the main axis spring strength. We obtained measurements 10 times for the gel sheets and simultaneously measured the load using a digital scale. We measured the hardness distribution of induration embedded and breast cancer palpation models, with a main axis with 1.96 N, 4.90 N, and 9.81 N spring strengths, to create a two-dimensional Contour Fill Chart. Using 4.90 N spring strength, we could obtain measurement loads of ≤3.0 N, and the mean hardness was 5.14 mm. This was close to the median of the total measurement range 0.0-10.0 mm, making the measurement range the largest for this spring strength. We could image the induration of the induration-embedded model regardless of the spring strength. Overall, 4.90 N spring strength was best suited for imaging cancer in the breast cancer palpation model. Copyright © 2017. Published by Elsevier B.V.

  13. Rate dependent strengths of some solder joints

    NASA Astrophysics Data System (ADS)

    Williamson, D. M.; Field, J. E.; Palmer, S. J. P.; Siviour, C. R.

    2007-08-01

    The shear strengths of three lead-free solder joints have been measured over the range of loading rates 10-3 to ~105 mm min-1. Binary (SnAg), ternary (SnAgCu) and quaternary (Castin: SnAgCuSb) alloys have been compared to a conventional binary SnPb solder alloy. Results show that at loading rates from 10-3 to 102 mm min-1, all four materials exhibit a linear relationship between the shear strength and the loading rate when the data are plotted on a log-log plot. At the highest loading rate of 105 mm min-1, the strengths of the binary alloys were in agreement with extrapolations made from the lower loading rate data. In contrast, the strengths of the higher order alloys were found to be significantly lower than those predicted by extrapolation. This is explained by a change in failure mechanism on the part of the higher order alloys. Similar behaviour was found in measurements of the tensile strengths of solder joints using a novel high-rate loading tensile test. Optical and electron microscopy were used to examine the microstructures of interest in conjunction with energy dispersive x-ray analysis for elemental identification. The effect of artificial aging and reflow of the solder joints is also reported.

  14. The effect of shredding and test apparatus size on compressibility and strength parameters of degraded municipal solid waste.

    PubMed

    Hossain, M S; Gabr, M A; Asce, F

    2009-09-01

    In many situations, MSW components are processed and shredded before use in laboratory experiments using conventional soil testing apparatus. However, shredding MSW material may affect the target property to be measured. The objective of this study is to contribute to the understanding of the effect of shredding of MSW on the measured compressibility and strength properties. It is hypothesized that measured properties can be correlated to an R-value, the ratio of waste particle size to apparatus size. Results from oedometer tests, conducted on 63.5 mm, 100 mm, 200 mm diameter apparatus, indicated the dependency of the compressibility parameters on R-value. The compressibility parameters are similar for the same R-value even though the apparatus size varies. The results using same apparatus size with variable R-values indicated that shredding of MSW mainly affects initial compression. Creep and biological strain rate of the tested MSW are not significantly affected by R-value. The shear strength is affected by shredding as the light-weight reinforcing materials are shredded into smaller pieces during specimen preparation. For example, the measured friction angles are 32 degrees and 27 degrees for maximum particle sizes of 50 mm and 25 mm, respectively. The larger MSW components in the specimen provide better reinforcing contribution. This conclusion is however dependent on comparing specimen at the same level of degradation since shear strength is also a function of extent of degradation.

  15. Strength training for children and adolescents.

    PubMed

    Faigenbaum, A D

    2000-10-01

    The potential benefits of youth strength training extend beyond an increase in muscular strength and may include favorable changes in selected health- and fitness-related measures. If appropriate training guidelines are followed, regular participation in a youth strength-training program has the potential to increase bone mineral density, improve motor performance skills, enhance sports performance, and better prepare our young athletes for the demands of practice and competition. Despite earlier concerns regarding the safety and efficacy of youth strength training, current public health objectives now aim to increase the number of boys and girls age 6 and older who regularly participate in physical activities that enhance and maintain muscular fitness. Parents, teachers, coaches, and healthcare providers should realize that youth strength training is a specialized method of conditioning that can offer enormous benefit but at the same time can result in serious injury if established guidelines are not followed. With qualified instruction, competent supervision, and an appropriate progression of the volume and intensity of training, children and adolescents cannot only learn advanced strength training exercises but can feel good about their performances, and have fun. Additional clinical trails involving children and adolescents are needed to further explore the acute and chronic effects of strength training on a variety of anatomical, physiological, and psychological parameters.

  16. Pathogens as Predictors of Honey Bee Colony Strength in England and Wales.

    PubMed

    Budge, Giles E; Pietravalle, Stéphane; Brown, Mike; Laurenson, Lynn; Jones, Ben; Tomkies, Victoria; Delaplane, Keith S

    2015-01-01

    Inspectors with the UK National Bee Unit were asked for 2007-2008 to target problem apiaries in England and Wales for pathogen screening and colony strength measures. Healthy colonies were included in the sampling to provide a continuum of health conditions. A total of 406 adult bee samples was screened and yielded 7 viral, 1 bacterial, and 2 microsporidial pathogens and 1 ectoparasite (Acarapis woodi). In addition, 108 samples of brood were screened and yielded 4 honey bee viruses. Virus prevalence varied from common (deformed wing virus, black queen cell virus) to complete absence (Israeli acute paralysis virus). When colonies were forced into one of two classes, strong or weak, the weak colonies contained more pathogens in adult bees. Among observed pathogens, only deformed wing virus was able to predict colony strength. The effect was negative such that colonies testing positive for deformed wing virus were likely to have fewer combs of bees or brood. This study constitutes the first record for Nosema ceranae in Great Britain. These results contribute to the growing body of evidence linking pathogens to poor honey bee health.

  17. Measurement of Ligand–Target Residence Times by 1H Relaxation Dispersion NMR Spectroscopy

    PubMed Central

    2016-01-01

    A ligand-observed 1H NMR relaxation experiment is introduced for measuring the binding kinetics of low-molecular-weight compounds to their biomolecular targets. We show that this approach, which does not require any isotope labeling, is applicable to ligand–target systems involving proteins and nucleic acids of variable molecular size. The experiment is particularly useful for the systematic investigation of low affinity molecules with residence times in the micro- to millisecond time regime. PMID:27933946

  18. Measurement and calibration of differential Mueller matrix of distributed targets

    NASA Technical Reports Server (NTRS)

    Sarabandi, Kamal; Oh, Yisok; Ulaby, Fawwaz T.

    1992-01-01

    A rigorous method for calibrating polarimetric backscatter measurements of distributed targets is presented. By characterizing the radar distortions over the entire mainlobe of the antenna, the differential Mueller matrix is derived from the measured scattering matrices with a high degree of accuracy. It is shown that the radar distortions can be determined by measuring the polarimetric response of a metallic sphere over the main lobe of the antenna. Comparison of results obtained with the new algorithm with the results derived from the old calibration method show that the discrepancy between the two methods is less than 1 dB for the backscattering coefficients. The discrepancy is more drastic for the phase-difference statistics, indicating that removal of the radar distortions from the cross products of the scattering matrix elements cannot be accomplished with the traditional calibration methods.

  19. Relationship between isometric and dynamic strength in recreationally trained men.

    PubMed

    McGuigan, Michael R; Newton, Michael J; Winchester, Jason B; Nelson, Arnold G

    2010-09-01

    The purpose of this investigation was to examine the relationships between measures of maximal isometric force (peak force [PF]), rate of force development (RFD), vertical jump performance (VJ) and 1-repetition maximum (1RM) strength in recreationally trained men. The subjects in this study were 26 men ([mean +/- SD]: age 22 +/- 1 years; height 175 +/- 7 cm; mass 90 +/- 10 kg). They were tested for PF using the isometric midthigh pull exercise. The 1RM for the squat and bench press exercise were determined as a measure of dynamic strength. Explosive strength was measured as RFD from the isometric force-time curve. Correlations between the variables were calculated using Pearson product moment correlation coefficient. There was a nearly perfect correlation between measures of PF and 1RM squat (r = 0.97, p < 0.05) and 1RM bench press (r = 0.99, p < 0.05). The correlations were very strong between VJ and PF (r = 0.72, p < 0.05) and 1RM bench press (r = 0.70, p < 0.05). There were also strong correlations between VJ and 1RM squat (r = 0.69, p < 0.05). There were no significant correlations with RFD. The results showed that isometric maximum strength determined during the isometric midthigh pull test correlated well with 1RM and VJ testing. However, RFD measured during the same test did not appear to correlate as well with other measures. The isometric midthigh pull provides an efficient method for assessing strength in recreationally trained individuals. Practitioners wishing to obtain performance data related to maximum strength may wish to consider isometric testing as a less time intensive method of testing.

  20. Strength capability while kneeling.

    PubMed

    Haslegrave, C M; Tracy, M F; Corlett, E N

    1997-12-01

    Work sometimes has to be carried out kneeling, particularly where jobs are performed in confined spaces as is common for miners, aircraft baggage handlers and maintenance workers. In order to assess the risks in performing forceful tasks under such conditions, data is needed on strength capabilities of kneeling subjects. A study was undertaken to measure isometric strength in single-handed exertions for male subjects and to investigate the effects on this of task layout factors (direction of force exertion, reach distance, height of the workpiece and orientation relative to the subject's sagittal plane). The data has been tabulated to show the degree to which strength may be reduced in different situations and analysis of the task factors showed their influence to be complex with direction of exertion and reach distance having the greatest effect. The results also suggest that exertions are weaker when subjects are kneeling on two knees than when kneeling on one knee, although this needs to be confirmed by direct experimental comparison.

  1. Examining the target levels of state renewable portfolio standards

    NASA Astrophysics Data System (ADS)

    Helwig, Laurence Douglas

    At present 37 U.S. states have passed Renewable Portfolio Standards (RPS) or have a legislative driven goal that supports investment in renewable energy (RE) technologies. Previous research has identified economic, governmental, ideological and infrastructural characteristics as key predictors of policy adoption and renewable energy deployment efforts (Carley, 2009; Davis & Davis, 2009; Bohn & Lant, 2009; Lyon & Yin, 2010). To date, only a few studies have investigated the target levels of renewable portfolio standards. Carley & Miller (2012) found that policies of differing stringencies were motivated by systematically different factors that included governmental ideology. The purpose of this dissertation is to replicate and expand upon earlier models that predicted RPS adoption and RE deployment efforts by adding regulatory, infrastructural and spatial characteristics to predict RPS target levels. Hypotheses were tested using three alternative measurements of RPS target level strength to determine to what extent a combination of explanatory variables explain variation in policy target levels. Multivariate linear regression and global spatial autocorrelation results indicated that multiple state internal determinants influenced RPS target level including average electricity price, state government ideology and to a lesser extent actual RE potential capacity. In addition, some diffusion effects were found to exist that indicated that states are setting their RPS target levels lower than their neighboring states and a local geo-spatial clustering effect was observed in the target levels for a grouping of northeastern states.

  2. Cut points of muscle strength associated with metabolic syndrome in men.

    PubMed

    Sénéchal, Martin; McGavock, Jonathan M; Church, Timothy S; Lee, Duck-Chul; Earnest, Conrad P; Sui, Xuemei; Blair, Steven N

    2014-08-01

    The loss of muscle strength with age increases the likelihood of chronic conditions, including metabolic syndrome (MetS). However, the minimal threshold of muscle strength at which the risk for MetS increases has never been established. This study aimed to identify a threshold of muscle strength associated with MetS in men. We created receiver operating curves for muscle strength and the risk of MetS from a cross-sectional sample of 5685 men age <50 yr and 1541 men age ≥50 yr enrolled in the Aerobics Center Longitudinal Study. The primary outcome measure, the MetS, was defined according to the National Cholesterol Education Program Adult Treatment Panel III criteria. Upper and lower body muscle strength was treated as a composite measure of one-repetition maximum tests on bench and leg press and scaled to body weight. Low muscle strength was defined as the lowest age-specific 20th percentile, whereas high muscle strength was defined as composite muscle strength above the 20th percentile. In men aged <50 yr, the odds of MetS were 2.20-fold (95% confidence interval = 1.89-2.54) higher in those with low muscle strength, independent of age, smoking, and alcohol intake. The strength of this association was similar for men age ≥50 yr (odds ratio = 2.11, 95% confidence interval = 1.62-2.74). In men age < 50 yr, the composite strength threshold associated with MetS was 2.57 kg·kg body weight, whereas in men age ≥ 50 yr the threshold was 2.35 kg·kg body weight. This study is the first to identify a threshold of muscle strength associated with an increased likelihood of MetS in men. Measures of muscle strength may help identify men at risk of chronic disease.

  3. Childhood cardiorespiratory fitness, muscular fitness and adult measures of glucose homeostasis.

    PubMed

    Fraser, Brooklyn J; Blizzard, Leigh; Schmidt, Michael D; Juonala, Markus; Dwyer, Terence; Venn, Alison J; Magnussen, Costan G

    2018-02-14

    To assess whether childhood cardiorespiratory fitness (CRF) and muscular fitness phenotypes (strength, power, endurance) predict adult glucose homeostasis measures. Prospective longitudinal study. Study examining participants who had physical fitness measured in childhood (aged 7-15 years) and who attended follow-up clinics approximately 20 years later and provided a fasting blood sample which was tested for glucose and insulin. Physical fitness measurements included muscular strength (right and left grip, shoulder flexion, shoulder and leg extension), power (standing long jump distance) and endurance (number of push-ups in 30s), and CRF (1.6km run duration). In adulthood, fasting glucose and insulin levels were used to derive glucose homeostasis measures of insulin resistance (HOMA2-IR) and beta cell function (HOMA2-β). A standard deviation increase in childhood CRF or muscular strength (males) was associated with fasting glucose (CRF: β=-0.06mmol/L), fasting insulin (CRF: β=-0.73mU/L; strength: β=-0.40mU/L), HOMA2-IR (CRF: β=-0.06; strength: β=-0.05) and HOMA2-β (CRF: β=-3.06%; strength: β=-2.62%) in adulthood, independent of the alternative fitness phenotype (all p<0.01). Adjustment for childhood waist circumference reduced the effect by 17-35% for CRF and 0-15% for muscular strength (males) and statistical significance remained for all associations expect between CRF, fasting glucose and HOMA2-β (p>0.06). CRF and muscular fitness in childhood were inversely associated with measures of fasting insulin, insulin resistance and beta cell function in adulthood. Childhood CRF and muscular fitness could both be potential independent targets for strategies to help reduce the development of adverse glucose homeostasis. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  4. The effects of isolated and integrated 'core stability' training on athletic performance measures: a systematic review.

    PubMed

    Reed, Casey A; Ford, Kevin R; Myer, Gregory D; Hewett, Timothy E

    2012-08-01

    Core stability training, operationally defined as training focused to improve trunk and hip control, is an integral part of athletic development, yet little is known about its direct relation to athletic performance. This systematic review focuses on identification of the association between core stability and sports-related performance measures. A secondary objective was to identify difficulties encountered when trying to train core stability with the goal of improving athletic performance. A systematic search was employed to capture all articles related to athletic performance and core stability training that were identified using the electronic databases MEDLINE, CINAHL and SPORTDiscus™ (1982-June 2011). A systematic approach was used to evaluate 179 articles identified for initial review. Studies that performed an intervention targeted toward the core and measured an outcome related to athletic or sport performances were included, while studies with a participant population aged 65 years or older were excluded. Twenty-four in total met the inclusionary criteria for review. Studies were evaluated using the Physical Therapy Evidence Database (PEDro) scale. The 24 articles were separated into three groups, general performance (n = 8), lower extremity (n = 10) and upper extremity (n = 6), for ease of discussion. In the majority of studies, core stability training was utilized in conjunction with more comprehensive exercise programmes. As such, many studies saw improvements in skills of general strengths such as maximum squat load and vertical leap. Surprisingly, not all studies reported measurable increases in specific core strength and stability measures following training. Additionally, investigations that targeted the core as the primary goal for improved outcome of training had mixed results. Core stability is rarely the sole component of an athletic development programme, making it difficult to directly isolate its affect on athletic performance

  5. Leg Strength Comparison between Younger and Middle-age Adults

    PubMed Central

    Kim, Sukwon; Lockhart, Thurmon; Nam, Chang S.

    2009-01-01

    Although a risk of occupational musculoskeletal diseases has been identified with age-related strength degradation, strength measures from working group are somewhat sparse. This is especially true for the lower extremity strength measures in dynamic conditions (i.e., isokinetic). The objective of this study was to quantify the lower extremity muscle strength characteristics of three age groups (young, middle, and the elderly). Total of 42 subjects participated in the study: 14 subjects for each age group. A commercial dynamometer was used to evaluate isokinetic and isometric strength at ankle and knee joints. 2 × 2 (Age group (younger, middle-age, and older adult groups) × Gender (male and female)) between-subject design and Post-hoc analysis were performed to evaluate strength differences among three age groups. Post-hoc analysis indicated that, overall, middle-age workers’ leg strengths (i.e. ankle and knee muscles) were significantly different from younger adults while middle-age workers’ leg strengths were virtually identical to older adults’ leg strengths. These results suggested that, overall, 14 middle-age workers in the present study could be at a higher risk of musculoskeletal injuries. Future studies looking at the likelihood of musculoskeletal injuries at different work places and from different working postures at various age levels should be required to validate the current findings. The future study would be a valuable asset in finding intervention strategies such that middle-age workers could stay healthier longer. PMID:20436934

  6. Comparison of Three Methods of Assessing Muscle Strength and Imbalance Ratios of the Knee

    PubMed Central

    Moss, Crayton L.; Wright, P. Thomas

    1993-01-01

    Three strength measurement methods for determining muscle strength and imbalance ratios of the knee were compared in 41 (23 female, 18 male) NCAA Division I track and field athletes. Peak quadriceps extensions and hamstring flexions were measured isotonically, isometrically, and isokinetically. Isokinetic measurements were performed on a Cybex II at 60°/s. Isometric extension and flexion measurements were performed using the Nicholas Manual Muscle Tester (Lafayette Instruments; Lafayette, Ind). Isotonic measurements were done on both Universal and Nautilus apparatuses. Testing order was randomized to avoid a treatment order effect. A repeated measures ANOVA and a post hoc Tukey test were used to compare the three methods of assessing strength and imbalance ratios of the knee. Absolute strength values were significantly different according to gender and mode of testing. Bilateral strength imbalance ratios for knee flexion were significantly lower for the Nautilus leg curl machine. Ipsilateral strength imbalance ratios were significantly greater for the Cybex II. Our results indicated that absolute strength values cannot be interchanged between testing modes. Except for Cybex II (ipsilateral) and Nautilus (bilateral knee flexion), strength imbalance ratios could be interchanged. ImagesFig 1.Fig 2.Fig 3.Fig 4.Fig 5.Fig 6.Fig 7.INGING PMID:16558207

  7. Measurements of Laser Imprint with High-Z Coated targets on Omega EP

    NASA Astrophysics Data System (ADS)

    Karasik, Max; Oh, J.; Stoeckl, C.; Aglitskiy, Y.; Schmitt, A. J.; Bates, J. W.; Obenschain, S. P.

    2015-11-01

    Previous experiments on Nike KrF laser (λ = 248nm) at NRL found that a thin (400-800 Å) high-Z (Au or Pd) overcoat on the laser side of the target is effective in suppressing broadband imprint and reducing ablative Richtmyer-Meshkov growth. The overcoat initially absorbs the laser and emits soft x-rays that ablate the target, forming a large stand-off distance between laser absorption and ablation and driving the target at higher mass ablation rate. Implementation of this technique on the frequency-tripled Nd:glass (351 nm) NIF would enable a wider range direct drive experiments there. To this end, we are carrying out experiments using the NIF-like beams of Omega EP. Analogous to experiments on Nike, areal mass perturbations due to RT-amplified laser imprint are measured using curved crystal imaging coupled to a streak camera. High-Z coating dynamics and target trajectory are imaged side-on. First results indicate that imprint suppression is observed, albeit with thicker coatings. Work supported by the Department of Energy/NNSA.

  8. Strength of Virginia's 1.

    DOT National Transportation Integrated Search

    1993-01-01

    This study was undertaken to measure what, if any, differences exist in strength between mixtures made with 3/4-in (19-mm) maximum size aggregate and those made with 1/2-in (13-mm) maximum size aggregate. In order to make a comparison, a definition o...

  9. Behavior and Frequency Analysis of Aurelia aurita by Using in situ Target Strength at a Port in Southwestern Korea

    NASA Astrophysics Data System (ADS)

    Yoon, Eun-A.; Hwang, Doo-Jin; Chae, Jinho; Yoon, Won Duk; Lee, Kyounghoon

    2018-03-01

    This study was carried out to determine the in situ target strength and behavioral characteristics of moon jellyfish ( Aurelia aurita) using two frequencies (38 and 120 kHz) that present a 2- frequency-difference method for distinguishing A. aurita from other marine planktonic organisms. The average TS was shown as -71.9 -67.9 dB at 38 kHz and -75.5 -66.0 dB at 120 kHz and the average ΔMVBS120-38 kHz was similar at -1.5 3.5 dB. The TS values varied in a range of about 14 dB from -83.3 and -69.0 dB depending on the pulsation of A. aurita. The species moved in a range of -0.1 1.0 m and they mostly moved horizontally with moving speeds of 0.3 0.6 m·s-1. The TS and behavioral characteristics of A. aurita can distinguish the species from others. The acoustic technology can also contribute to understanding the distribution and abundance of the species.

  10. Electric Monopole Transition Strengths in 62Ni

    NASA Astrophysics Data System (ADS)

    Evitts, L. J.; Garnsworthy, A. B.; Kibédi, T.; Moukaddam, M.; Alshahrani, B.; Eriksen, T. K.; Holt, J. D.; Hota, S. S.; Lane, G. J.; Lee, B. Q.; McCormick, B. P.; Palalani, N.; Reed, M. W.; Stroberg, S. R.; Stuchbery, A. E.

    2016-09-01

    Excited states in 62Ni were populated with a (p, p') reaction using the 14UD Pelletron accelerator at the Australian National University. Electric monopole transition strengths, ρ2(E0), were measured through simultaneous detection of the internal conversion electrons and γ rays emitted from the de-excitation of populated states, using the Super-e spectrometer coupled with a germanium detector. The strength of the 02+ to 01+ transition has been measured to be 77-34+23 × 10-3 and agrees with previously reported values. Upper limits have been placed on the 03+ to 01+ and 03+ to 02+ transitions. The measured ρ2(E0) value of the 22+ to 21+ transition in 62Ni has been measured for the first time and found to be one of the largest ρ2(E0) values measured to date in nuclei heavier than Ca. The low-lying states of 62Ni have previously been classified as one- and two-phonon vibrational states based on level energies. The measured electric quadrupole transition strengths are consistent with this interpretation. However as electric monopole transitions are forbidden between states which differ by one phonon number, the simple harmonic quadrupole vibrational picture is not suffcient to explain the large ρ2(E0) value for the 22+ to 21+ transition.

  11. Persistence of long term isokinetic strength deficits in subjects with lateral ankle sprain as measured with a protocol including maximal preloading.

    PubMed

    Perron, Marc; Moffet, Hélène; Nadeau, Sylvie; Hébert, Luc J; Belzile, Sylvain

    2014-12-01

    The assessment of muscle function is a cornerstone in the management of subjects who have sustained a lateral ankle sprain. The ankle range of motion being relatively small, the use of preloading allows to measure maximal strength throughout the whole amplitude and therefore to better characterize ankle muscles weaknesses. This study aimed to assess muscle strength of the injured and uninjured ankles in subjects with a lateral ankle sprain, to document the timeline of strength recovery, and to determine the influence of sprain grade on strength loss. Maximal torque of the periarticular muscles of the ankle in a concentric mode using a protocol with maximal preloading was tested in 32 male soldiers at 8 weeks and 6 months post-injury. The evertor muscles of the injured ankles were weaker than the uninjured ones at 8 weeks and 6 months post-injury (P<0.0001, effect size=0.31-0.42). Muscle weaknesses also persisted in the plantarflexors of the injured ankles at 8 weeks (P=0.0014, effect size=0.52-0.58) while at 6 months, only the subjects with a grade II sprain displayed such weaknesses (P<0.0001, effect size 0.27-0.31). The strength of the invertor and dorsiflexor muscles did not differ between sides. The use of an isokinetic protocol with preloading demonstrates significant but small strength deficits in the evertor and plantarflexor muscles. These impairments may contribute to the high incidence of recurrence of lateral ankle sprain in very active individuals. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Turbulence Measurement in the Atmospheric Boundary Layer Using Cellular Telephone Signals

    DTIC Science & Technology

    2012-03-01

    TURBULENCE MEASUREMENT IN THE ATMOSPHERIC BOUNDARY LAYER USING CELLULAR TELEPHONE SIGNALS THESIS Lee R. Burchett, Civilian AFIT/APPLPHY/ENP/12 - M01...85 xiv TURBULENCE MEASUREMENT IN THE ATMOSPHERIC BOUNDARY LAYER USING CELLULAR TELEPHONE SIGNALS I. Introduction What follows is an...efficient use of these systems. For example, the effective range of a laser weapon is limited by the strength of turbulence on the path to the target

  13. The adhesive strength and initial viscosity of denture adhesives.

    PubMed

    Han, Jian-Min; Hong, Guang; Dilinuer, Maimaitishawuti; Lin, Hong; Zheng, Gang; Wang, Xin-Zhi; Sasaki, Keiichi

    2014-11-01

    To examine the initial viscosity and adhesive strength of modern denture adhesives in vitro. Three cream-type denture adhesives (Poligrip S, Corect Cream, Liodent Cream; PGS, CRC, LDC) and three powder-type denture adhesives (Poligrip Powder, New Faston, Zanfton; PGP, FSN, ZFN) were used in this study. The initial viscosity was measured using a controlled-stress rheometer. The adhesive strength was measured according to ISO-10873 recommended procedures. All data were analyzed independently by one-way analysis of variance combined with a Student-Newman-Keuls multiple comparison test at a 5% level of significance. The initial viscosity of all the cream-type denture adhesives was lower than the powder-type adhesives. Before immersion in water, all the powder-type adhesives exhibited higher adhesive strength than the cream-type adhesives. However, the adhesive strength of cream-type denture adhesives increased significantly and exceeded the powder-type denture adhesives after immersion in water. For powder-type adhesives, the adhesive strength significantly decreased after immersion in water for 60 min, while the adhesive strength of the cream-type adhesives significantly decreased after immersion in water for 180 min. Cream-type denture adhesives have lower initial viscosity and higher adhesive strength than powder type adhesives, which may offer better manipulation properties and greater efficacy during application.

  14. Maximal strength and power assessment in novice weight trainers.

    PubMed

    Cronin, John B; Henderson, Melanie E

    2004-02-01

    The purpose of this study was to investigate whether changes in maximal strength and power output occurred over time in the absence of strength and power training in novice weight trainers. It also investigated whether differences existed between upper- and lower-body assessments and unilateral and bilateral assessments. The power output and maximal strength (1 repetition maximum [1RM]) of 10 male novice subjects were measured on 4 occasions, each assessment 7-10 days apart. The exercises used to measure the upper- and lower-body strength and power outputs were the bench press and supine squat, respectively. Significant (p < 0.05) changes in unilateral (9.8-16.8%) and bilateral 1RM (6.8-15.0%) leg strength were found, the first assessment being significantly different from all other assessments and assessment 2 significantly different from assessment 4. Changes in the upper body (10-13.6%) were also observed. The only significant difference was between assessment 1 and the other testing occasions. No differences in power output were observed for both the upper and lower body during the study. It would seem that considerable changes in maximal strength occur rapidly and in the absence of any formal strength training program in novice weight trainers.

  15. Surrogate Modeling of High-Fidelity Fracture Simulations for Real-Time Residual Strength Predictions

    NASA Technical Reports Server (NTRS)

    Spear, Ashley D.; Priest, Amanda R.; Veilleux, Michael G.; Ingraffea, Anthony R.; Hochhalter, Jacob D.

    2011-01-01

    A surrogate model methodology is described for predicting in real time the residual strength of flight structures with discrete-source damage. Starting with design of experiment, an artificial neural network is developed that takes as input discrete-source damage parameters and outputs a prediction of the structural residual strength. Target residual strength values used to train the artificial neural network are derived from 3D finite element-based fracture simulations. A residual strength test of a metallic, integrally-stiffened panel is simulated to show that crack growth and residual strength are determined more accurately in discrete-source damage cases by using an elastic-plastic fracture framework rather than a linear-elastic fracture mechanics-based method. Improving accuracy of the residual strength training data would, in turn, improve accuracy of the surrogate model. When combined, the surrogate model methodology and high-fidelity fracture simulation framework provide useful tools for adaptive flight technology.

  16. Isometric and isokinetic hip strength and agonist/antagonist ratios in symptomatic femoroacetabular impingement.

    PubMed

    Diamond, Laura E; Wrigley, Tim V; Hinman, Rana S; Hodges, Paul W; O'Donnell, John; Takla, Amir; Bennell, Kim L

    2016-09-01

    This study investigated isometric and isokinetic hip strength in individuals with and without symptomatic femoroacetabular impingement (FAI). The specific aims were to: (i) determine whether differences exist in isometric and isokinetic hip strength measures between groups; (ii) compare hip strength agonist/antagonist ratios between groups; and (iii) examine relationships between hip strength and self-reported measures of either hip pain or function in those with FAI. Cross-sectional. Fifteen individuals (11 males; 25±5 years) with symptomatic FAI (clinical examination and imaging (alpha angle >55° (cam FAI), and lateral centre edge angle >39° and/or positive crossover sign (combined FAI))) and 14 age- and sex-matched disease-free controls (no morphological FAI on magnetic resonance imaging) underwent strength testing. Maximal voluntary isometric contraction strength of hip muscle groups and isokinetic hip internal (IR) and external rotation (ER) strength (20°/s) were measured. Groups were compared with independent t-tests and Mann-Whitney U tests. Participants with FAI had 20% lower isometric abduction strength than controls (p=0.04). There were no significant differences in isometric strength for other muscle groups or peak isokinetic ER or IR strength. The ratio of isometric, but not isokinetic, ER/IR strength was significantly higher in the FAI group (p=0.01). There were no differences in ratios for other muscle groups. Angle of peak IR torque was the only feature correlated with symptoms. Individuals with symptomatic FAI demonstrate isometric hip abductor muscle weakness and strength imbalance in the hip rotators. Strength measurement, including agonist/antagonist ratios, may be relevant for clinical management of FAI. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  17. Motor unit number estimates correlate with strength in polio survivors.

    PubMed

    Sorenson, Eric J; Daube, Jasper R; Windebank, Anthony J

    2006-11-01

    Motor unit number estimation (MUNE) has been proposed as an outcome measure in clinical trials for the motor neuron diseases. One major criticism of MUNE is that it may not represent a clinically meaningful endpoint. We prospectively studied a cohort of polio survivors over a period of 15 years with respect to MUNE and strength. We identified a significant association between thenar MUNE and arm strength, extensor digitorum brevis MUNE and leg strength, and the summated MUNE and global strength of the polio survivors. These findings confirm the clinical relevance of MUNE as an outcome measure in the motor neuron diseases and provide further validation for its use in clinical trial research.

  18. Heptameric Targeting Ligands against EGFR and HER2 with High Stability and Avidity

    PubMed Central

    Kim, Dongwook; Yan, Yitang; Valencia, C. Alexander; Liu, Rihe

    2012-01-01

    Multivalency of targeting ligands provides significantly increased binding strength towards their molecular targets. Here, we report the development of a novel heptameric targeting system, with general applications, constructed by fusing a target-binding domain with the heptamerization domain of the Archaeal RNA binding protein Sm1 through a flexible hinge peptide. The previously reported affibody molecules against EGFR and HER2, ZEGFR and ZHER2, were used as target binding moieties. The fusion molecules were highly expressed in E. coli as soluble proteins and efficiently self-assembled into multimeric targeting ligands with the heptamer as the predominant form. We demonstrated that the heptameric molecules were resistant to protease-mediated digestion or heat- and SDS-induced denaturation. Surface plasmon resonance (SPR) analysis showed that both heptameric ZEGFR and ZHER2 ligands have a significantly enhanced binding strength to their target receptors with a nearly 100 to 1000 fold increase relative to the monomeric ligands. Cellular binding assays showed that heptameric ligands maintained their target-binding specificities similar to the monomeric forms towards their respective receptor. The non-toxic property of each heptameric ligand was demonstrated by the cell proliferation assay. In general,, the heptamerization strategy we describe here could be applied to the facile and efficient engineering of other protein domain- or short peptide-based affinity molecules to acquire significantly improved target-binding strengths with potential applications in the targeted delivery of various imaging or therapeutic agents.. PMID:22912791

  19. Handgrip strength measurement as a predictor of hospitalization costs.

    PubMed

    Guerra, R S; Amaral, T F; Sousa, A S; Pichel, F; Restivo, M T; Ferreira, S; Fonseca, I

    2015-02-01

    Undernutrition status at hospital admission is related to increased hospital costs. Handgrip strength (HGS) is an indicator of undernutrition, but the ability of HGS to predict hospitalization costs has yet to be studied. To explore whether HGS measurement at hospital admission can predict patient's hospitalization costs. A prospective study was conducted in a university hospital. Inpatient's (n=637) HGS and undernutrition status by Patient-Generated Subjective Global Assessment were ascertained. Multivariable linear regression analysis, computing HGS quartiles by sex (reference: fourth quartile, highest), was conducted in order to identify the independent predictors of hospitalization costs. Costs were evaluated through percentage deviation from the mean cost, after adjustment for patients' characteristics, disease severity and undernutrition status. Being in the first or second HGS quartiles at hospital admission increased patient's hospitalization costs, respectively, by 17.5% (95% confidence interval: 2.7-32.3) and 21.4% (7.5-35.3), which translated into an increase from €375 (58-692) to €458 (161-756). After the additional adjustment for undernutrition status, being in the first or second HGS quartiles had, respectively, an economic impact of 16.6% (1.9-31.2) and 20.0% (6.2-33.8), corresponding to an increase in hospitalization expenditure from €356 (41-668) to €428 (133-724). Low HGS at hospital admission is associated with increased hospitalization costs of between 16.6 and 20.0% after controlling for possible confounders, including undernutrition status. HGS is an inexpensive, noninvasive and easy-to-use method that has clinical potential to predict hospitalization costs.

  20. Radiation force on absorbing targets and power measurements of a high intensity focused ultrasound (HIFU) source

    NASA Astrophysics Data System (ADS)

    Qian, Zuwen; Zhu, Zhemin; Ye, Shigong; Jiang, Wenhua; Zhu, Houqing; Yu, Jinshen

    2010-10-01

    Based on the analytic expressions for the radiated field of a circular concave piston given by Hasegawa et al., an integral for calculation of the radiation force on a plane absorbing target in a spherically focused field is derived. A general relation between acoustic power P and normal radiation force F n is obtained under the condition of kr ≫ 1. Numerical computation is carried out by using the symbolic computation program for practically focused sources and absorbing circular targets. The results show that, for a given source, there is a range of target positions where the radiation force is independent of the target’s position under the assumption that the contribution of the acoustic field behind the target to the radiation force can be neglected. The experiments are carried out and confirm that there is a range of target positions where the measured radiation force is basically independent of the target’s position even at high acoustic power (up to 700 W). It is believed that when the radiation force method is used to measure the acoustic power radiated from a focused source, the size of the target must be selected in such a way that no observable sound can be found in the region behind the target.

  1. An in vitro evaluation of diametral tensile strength and flexural strength of nanocomposite vs hybrid and minifill composites cured with different light sources (QTH vs LED).

    PubMed

    Garapati, Surendra Nath; Priyadarshini; Raturi, Piyush; Shetty, Dinesh; Srikanth, K Venkata

    2013-01-01

    Composites always remained the target of discussion due to lot of controversies around it. Mechanical properties are one of them. With the introduction of new technology and emergence of various composites which combine superior strength and polish retention, nanocomposites have led to a new spark in the dentistry. A recent curing unit LED with various curing modes claims to produce higher degree of conversion. The aim of this study was to evaluate the diametral tensile strength and flexural strength of nanocomposite, hybrid and minifill composites cured with different light sources (QTH vs LED). Seventy-two samples were prepared using different specially fabricated teflon molds, 24 samples of each composite were prepared for the diametral tensile strength (ADA specification no. 27) and the flexural strength (ISO 4049) of the 12 samples, six were cured with LED (Soft Start curing profile) and other six with QTH curing light and tested on a universal testing machine. The nanocomposite had highest diametral tensile strength and flexural strength which were equivalent to the hybrid composite and superior than the minifill composite. With the combination of superior esthetics and other optimized physical properties, this novel nanocomposite system would be useful for all posterior and anterior applications.

  2. Electric Monopole Transition Strengths in the Stable Nickel Isotopes

    NASA Astrophysics Data System (ADS)

    Evitts, Lee John

    A series of measurements of stable nickel isotopes were performed at the Australian National University in Canberra. Excited states in 58,60,62Ni were populated via inelastic scattering of proton beams delivered by the 14UD Pelletron accelerator. Multiple setups were used in order to determine the structure of low-lying states. The CAESAR array of Compton-suppressed HPGe detectors was used to measure the (E2/M1) mixing ratio of transitions from angular distributions of gamma rays. The Super-e spectrometer was used to measure conversion coefficients for a number of J to J transitions. The data obtained from both devices was combined with previously measured parent lifetimes and branching ratios to determine E0 transition strengths between J-pi transitions. The E0 transition strength for the second 0+ to first 0+ transitions in 60,62Ni have been measured for the first time through internal conversion electron detection. The experimental value of 132(+59,-70) for 62Ni agrees within 2 sigma of the previous result obtained from internal pair formation. However it is likely that the previous experimental results used an outdated theoretical model for internal pair formation emission. This work also represents the first measurements of E0 transition strengths between 2+ states in Ni isotopes. There is generally large E0 strength between the 2+ states, particularly in the second 2+ to first 2+ transition, however there is also a large uncertainty in the measurements owing to the difficulties involved in measuring conversion coefficients. In 62Ni, the E0 transition strength of 172(+62,-77) for the second 2+ to first 2+ transition gives further weight to the argument against the spherical vibrator model, as an E0 transition is forbidden if there is a change of only one phonon. The large measurement also indicates the presence of shape coexistence, complementing the recent experimental work carried out in the neutron-rich Ni isotopes.

  3. Evenness indices measure the signal strength of biweight site chronologies

    Treesearch

    Kurt H. Riitters

    1990-01-01

    The signal strength of a biweight site chronology is properly viewed as an outcome of analysis rather than as a property of the forest-climate system. It can be estimated by the evenness of the empirical weights that are assigned to individual trees. The approach is demonstrated for a 45-year biweight chronology obtained from 40 jack pine (Pinus banksiana Lamb.) trees...

  4. Oxide driven strength evolution of silicon surfaces

    DOE PAGES

    Grutzik, Scott J.; Milosevic, Erik; Boyce, Brad L.; ...

    2015-11-19

    Previous experiments have shown a link between oxidation and strength changes in single crystal silicon nanostructures but provided no clues as to the mechanisms leading to this relationship. Using atomic force microscope-based fracture strength experiments, molecular dynamics modeling, and measurement of oxide development with angle resolved x-ray spectroscopy we study the evolution of strength of silicon (111) surfaces as they oxidize and with fully developed oxide layers. We find that strength drops with partial oxidation but recovers when a fully developed oxide is formed and that surfaces intentionally oxidized from the start maintain their high initial strengths. MD simulations showmore » that strength decreases with the height of atomic layer steps on the surface. These results are corroborated by a completely separate line of testing using micro-scale, polysilicon devices, and the slack chain method in which strength recovers over a long period of exposure to the atmosphere. Lastly, combining our results with insights from prior experiments we conclude that previously described strength decrease is a result of oxidation induced roughening of an initially flat silicon (1 1 1) surface and that this effect is transient, a result consistent with the observation that surfaces flatten upon full oxidation.« less

  5. Genome-scale measurement of off-target activity using Cas9 toxicity in high-throughput screens.

    PubMed

    Morgens, David W; Wainberg, Michael; Boyle, Evan A; Ursu, Oana; Araya, Carlos L; Tsui, C Kimberly; Haney, Michael S; Hess, Gaelen T; Han, Kyuho; Jeng, Edwin E; Li, Amy; Snyder, Michael P; Greenleaf, William J; Kundaje, Anshul; Bassik, Michael C

    2017-05-05

    CRISPR-Cas9 screens are powerful tools for high-throughput interrogation of genome function, but can be confounded by nuclease-induced toxicity at both on- and off-target sites, likely due to DNA damage. Here, to test potential solutions to this issue, we design and analyse a CRISPR-Cas9 library with 10 variable-length guides per gene and thousands of negative controls targeting non-functional, non-genic regions (termed safe-targeting guides), in addition to non-targeting controls. We find this library has excellent performance in identifying genes affecting growth and sensitivity to the ricin toxin. The safe-targeting guides allow for proper control of toxicity from on-target DNA damage. Using this toxicity as a proxy to measure off-target cutting, we demonstrate with tens of thousands of guides both the nucleotide position-dependent sensitivity to single mismatches and the reduction of off-target cutting using truncated guides. Our results demonstrate a simple strategy for high-throughput evaluation of target specificity and nuclease toxicity in Cas9 screens.

  6. Genome-scale measurement of off-target activity using Cas9 toxicity in high-throughput screens

    PubMed Central

    Morgens, David W.; Wainberg, Michael; Boyle, Evan A.; Ursu, Oana; Araya, Carlos L.; Tsui, C. Kimberly; Haney, Michael S.; Hess, Gaelen T.; Han, Kyuho; Jeng, Edwin E.; Li, Amy; Snyder, Michael P.; Greenleaf, William J.; Kundaje, Anshul; Bassik, Michael C.

    2017-01-01

    CRISPR-Cas9 screens are powerful tools for high-throughput interrogation of genome function, but can be confounded by nuclease-induced toxicity at both on- and off-target sites, likely due to DNA damage. Here, to test potential solutions to this issue, we design and analyse a CRISPR-Cas9 library with 10 variable-length guides per gene and thousands of negative controls targeting non-functional, non-genic regions (termed safe-targeting guides), in addition to non-targeting controls. We find this library has excellent performance in identifying genes affecting growth and sensitivity to the ricin toxin. The safe-targeting guides allow for proper control of toxicity from on-target DNA damage. Using this toxicity as a proxy to measure off-target cutting, we demonstrate with tens of thousands of guides both the nucleotide position-dependent sensitivity to single mismatches and the reduction of off-target cutting using truncated guides. Our results demonstrate a simple strategy for high-throughput evaluation of target specificity and nuclease toxicity in Cas9 screens. PMID:28474669

  7. The effects of exercise on muscle strength, body composition, physical functioning and the inflammatory profile of older adults: a systematic review.

    PubMed

    Liberman, Keliane; Forti, Louis N; Beyer, Ingo; Bautmans, Ivan

    2017-01-01

    This systematic review reports the most recent literature regarding the effects of physical exercise on muscle strength, body composition, physical functioning and inflammation in older adults. All articles were assessed for methodological quality and where possible effect size was calculated. Thirty-four articles were included - four involving frail, 24 healthy and five older adults with a specific disease. One reported on both frail and nonfrail patients. Several types of exercise were used: resistance training, aerobic training, combined resistance training and aerobic training and others. In frail older persons, moderate-to-large beneficial exercise effects were noted on inflammation, muscle strength and physical functioning. In healthy older persons, effects of resistance training (most frequently investigated) on inflammation or muscle strength can be influenced by the exercise modalities (intensity and rest interval between sets). Muscle strength seemed the most frequently used outcome measure, with moderate-to-large effects obtained regardless the exercise intervention studied. Similar effects were found in patients with specific diseases. Exercise has moderate-to-large effects on muscle strength, body composition, physical functioning and inflammation in older adults. Future studies should focus on the influence of specific exercise modalities and target the frail population more.

  8. Experimental knee joint pain during strength training and muscle strength gain in healthy subjects: a randomized controlled trial.

    PubMed

    Sørensen, T J; Langberg, H; Hodges, P W; Bliddal, H; Henriksen, M

    2012-01-01

    Knee joint pain and reduced quadriceps strength are cardinal symptoms in many knee pathologies. In people with painful knee pathologies, quadriceps exercise reduces pain, improves physical function, and increases muscle strength. A general assumption is that pain compromises muscle function and thus may prevent effective rehabilitation. This study evaluated the effects of experimental knee joint pain during quadriceps strength training on muscle strength gain in healthy individuals. Twenty-seven healthy untrained volunteers participated in a randomized controlled trial of quadriceps strengthening (3 times per week for 8 weeks). Participants were randomized to perform resistance training either during pain induced by injections of painful hypertonic saline (pain group, n = 13) or during a nonpainful control condition with injection of isotonic saline (control group, n = 14) into the infrapatellar fat pad. The primary outcome measure was change in maximal isokinetic muscle strength in knee extension/flexion (60, 120, and 180 degrees/second). The group who exercised with pain had a significantly larger improvement in isokinetic muscle strength at all angular velocities of knee extension compared to the control group. In knee flexion there were improvements in isokinetic muscle strength in both groups with no between-group differences. Experimental knee joint pain improved the training-induced gain in muscle strength following 8 weeks of quadriceps training. It remains to be studied whether knee joint pain has a positive effect on strength gain in patients with knee pathology. Copyright © 2012 by the American College of Rheumatology.

  9. Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt.

    PubMed

    Aramaki, Hidefumi; Katoh, Munenori; Hiiragi, Yukinobu; Kawasaki, Tsubasa; Kurihara, Tomohisa; Ohmi, Yorikatsu

    2016-07-01

    [Purpose] This study aimed to investigate the relatedness, reliability, and validity of isometric muscle strength measurements of hip abduction and abduction with an external hip rotation in a bent-hip position using a handheld dynamometer with a belt. [Subjects and Methods] Twenty healthy young adults, with a mean age of 21.5 ± 0.6 years were included. Isometric hip muscle strength in the subjects' right legs was measured under two posture positions using two devices: a handheld dynamometer with a belt and an isokinetic dynamometer. Reliability was evaluated using an intra-class correlation coefficient (ICC); relatedness and validity were evaluated using Pearson's product moment correlation coefficient. Differences in measurements of devices were assessed by two-way ANOVA. [Results] ICC (1, 1) was ≥0.9; significant positive correlations in measurements were found between the two devices under both conditions. No main effect was found between the measurement values. [Conclusion] Our findings revealed that there was relatedness, reliability, and validity of this method for isometric muscle strength measurements using a handheld dynamometer with a belt.

  10. Line identifications, line strengths, and continuum flux measurements in the ultraviolet spectrum of Arcturus

    NASA Technical Reports Server (NTRS)

    Carpenter, K. G.; Wing, R. F.; Stencel, R. E.

    1985-01-01

    The ultraviolet spectrum of Arcturus has been observed at high resolution with the IUE satellite. Line identifications, mean absolute 'continuum' flux measurements, integrated absolute emission-line fluxes, and measurements of selected absorption line strengths are presented for the 2250-2930 A region. In the 1150-2000 A region, identifications are given primarily on the basis of low-resolution spectra. Chromospheric emission lines have been identified with low-excitation species including H I, C I, C II, O I, Mg I, Mg II, Al II, Si I, Si II, S I, and Fe II; there is no evidence for lines of C IV, N V, or other species requiring high temperatures. A search for molecular absorption features in the 2500-2930 A interval has led to several tentative identifications, but only OH could be established as definitely present. Iron lines strongly dominate the identifications in the 2250-2930 A region, Fe II accounting for about 86 percent of the emission features and Fe I for 43 percent of the identified absorption features.

  11. Effect of Movement Velocity During Resistance Training on Dynamic Muscular Strength: A Systematic Review and Meta-Analysis.

    PubMed

    Davies, Timothy B; Kuang, Kenny; Orr, Rhonda; Halaki, Mark; Hackett, Daniel

    2017-08-01

    Movement velocity is an acute resistance-training variable that can be manipulated to potentially optimize dynamic muscular strength development. However, it is unclear whether performing faster or slower repetitions actually influences dynamic muscular strength gains. We conducted a systematic review and meta-analysis to examine the effect of movement velocity during resistance training on dynamic muscular strength. Five electronic databases were searched using terms related to movement velocity and resistance training. Studies were deemed eligible for inclusion if they met the following criteria: randomized and non-randomized comparative studies; published in English; included healthy adults; used isotonic resistance-exercise interventions directly comparing fast or explosive training to slower movement velocity training; matched in prescribed intensity and volume; duration ≥4 weeks; and measured dynamic muscular strength changes. A total of 15 studies were identified that investigated movement velocity in accordance with the criteria outlined. Fast and moderate-slow resistance training were found to produce similar increases in dynamic muscular strength when all studies were included. However, when intensity was accounted for, there was a trend for a small effect favoring fast compared with moderate-slow training when moderate intensities, defined as 60-79% one repetition maximum, were used (effect size 0.31; p = 0.06). Strength gains between conditions were not influenced by training status and age. Overall, the results suggest that fast and moderate-slow resistance training improve dynamic muscular strength similarly in individuals within a wide range of training statuses and ages. Resistance training performed at fast movement velocities using moderate intensities showed a trend for superior muscular strength gains as compared to moderate-slow resistance training. Both training practices should be considered for novice to advanced, young and older

  12. Effects of Swiss-ball core strength training on strength, endurance, flexibility, and balance in sedentary women.

    PubMed

    Sekendiz, Betül; Cuğ, Mutlu; Korkusuz, Feza

    2010-11-01

    The purpose of this study was to investigate the effects of Swiss-ball core strength training on trunk extensor (abdominal)/flexor (lower back) and lower limb extensor (quadriceps)/flexor (hamstring) muscular strength, abdominal, lower back and leg endurance, flexibility and dynamic balance in sedentary women (n = 21; age = 34 ± 8.09; height = 1.63 ± 6.91 cm; weight = 64 ± 8.69 kg) trained for 45 minutes, 3 d·wk-1 for 12 weeks. Results of multivariate analysis revealed significant difference (p ≤ 0.05) between pre and postmeasures of 60 and 90° s trunk flexion/extension, 60 and 240° s-1 lower limb flexion/extension (Biodex Isokinetic Dynamometer), abdominal endurance (curl-up test), lower back muscular endurance (modified Sorensen test), lower limb endurance (repetitive squat test), lower back flexibility (sit and reach test), and dynamic balance (functional reach test). The results support the fact that Swiss-ball core strength training exercises can be used to provide improvement in the aforementioned measures in sedentary women. In conclusion, this study provides practical implications for sedentary individuals, physiotherapists, strength and conditioning specialists who can benefit from core strength training with Swiss balls.

  13. Culture First: Boosting Program Strength through Cultural Instruction

    ERIC Educational Resources Information Center

    Windham, Scott

    2017-01-01

    In recent years, cultural instruction has been touted as a way to help foreign language programs boost student learning outcomes, enrollments, and many other measures of program strength. In order to investigate the relationship between cultural instruction and program strength in a university-level German program, students in first- and…

  14. Effect of 8 weeks of free-weight and machine-based strength training on strength and power performance

    PubMed Central

    Wirth, Klaus; Hartmann, Hagen; Sander, Andre; Mickel, Christoph

    2016-01-01

    Abstract The aim of this study was to evaluate the effectiveness of free-weight and machine-based exercises to increase different strength and speed-strength variables. One hundred twenty male participants (age: 23.8 ± 2.5 years; body height: 181.0 ± 6.8 cm; body mass: 80.2 ± 8.9 kg) joined the study. The 2 experimental groups completed an 8 week periodized strength training program that included 2 training sessions per week. The exercises that were used in the strength training programs were the parallel barbell squat and the leg press. Before and after the training period, the 1-repetition-maximum in the barbell squat and the leg press, the squat jump, the countermovement jump and unilateral isometric force (maximal isometric force and the rate of force development) were evaluated. To compare each group pre vs. post-intervention, analysis of variance with repeated measures and Scheffé post-hoc tests were used. The leg press group increased their 1-repetition-maximum significantly (p < 0.001), while in the squat group such variables as 1-repetition-maximum, the squat jump and the countermovement jump increased significantly (p < 0.001). The maximal isometric force showed no statistically significant result for the repeated measures factor, while the rate of force development of the squat group even showed a statistically significant decrease. Differences between the 2 experimental groups were detected for the squat jump and the countermovement jump. In comparison with the leg press, the squat might be a better strength training exercise for the development of jump performance. PMID:28149424

  15. Effect of 8 weeks of free-weight and machine-based strength training on strength and power performance.

    PubMed

    Wirth, Klaus; Keiner, Michael; Hartmann, Hagen; Sander, Andre; Mickel, Christoph

    2016-12-01

    The aim of this study was to evaluate the effectiveness of free-weight and machine-based exercises to increase different strength and speed-strength variables. One hundred twenty male participants (age: 23.8 ± 2.5 years; body height: 181.0 ± 6.8 cm; body mass: 80.2 ± 8.9 kg) joined the study. The 2 experimental groups completed an 8 week periodized strength training program that included 2 training sessions per week. The exercises that were used in the strength training programs were the parallel barbell squat and the leg press. Before and after the training period, the 1-repetition-maximum in the barbell squat and the leg press, the squat jump, the countermovement jump and unilateral isometric force (maximal isometric force and the rate of force development) were evaluated. To compare each group pre vs. post-intervention, analysis of variance with repeated measures and Scheffé post-hoc tests were used. The leg press group increased their 1-repetition-maximum significantly (p < 0.001), while in the squat group such variables as 1-repetition-maximum, the squat jump and the countermovement jump increased significantly (p < 0.001). The maximal isometric force showed no statistically significant result for the repeated measures factor, while the rate of force development of the squat group even showed a statistically significant decrease. Differences between the 2 experimental groups were detected for the squat jump and the countermovement jump. In comparison with the leg press, the squat might be a better strength training exercise for the development of jump performance.

  16. Negative pressure and spallation in graphite targets under nano- and picosecond laser irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belikov, R S; Khishchenko, K V; Krasyuk, I K

    We present the results of experiments on the spallation phenomena in graphite targets under shock-wave nano- and picosecond irradiation, which have been performed on Kamerton-T (GPI, Moscow, Russia) and PHELIX (GSI, Darmstadt, Germany) laser facilities. In the range of the strain rates of 10{sup 6} – 10{sup 7} s{sup -1}, the data on the dynamic mechanical strength of the material at rapure (spallation) have been for the first time obtained. With a maximal strain rate of 1.4 × 10{sup 7} s{sup -1}, the spall strength of 2.1 GPa is obtained, which constitutes 64% of the theoretical ultimate tensile strength ofmore » graphite. The effect of spallation is observed not only on the rear side of the target, but also on its irradiated (front) surface. With the use of optical and scanning electron microscopes, the morphology of the front and rear surfaces of the targets is studied. By means of Raman scattering of light, the graphite structure both on the target front surface under laser exposure and on its rear side in the spall zone is investigated. A comparison of the dynamic strength of graphite and synthetic diamond is performed. (extreme light fields and their applications)« less

  17. A method for measuring coherent elastic neutrino-nucleus scattering at a far off-axis high-energy neutrino beam target

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brice, S. J.; Cooper, R. L.; DeJongh, F.

    2014-04-03

    We present an experimental method for measuring the process of coherent elastic neutrino-nucleus scattering (CENNS). This method uses a detector situated transverse to a high-energy neutrino beam production target. This detector would be sensitive to the low-energy neutrinos arising from decay-at-rest pions in the target. We discuss the physics motivation for making this measurement and outline the predicted backgrounds and sensitivities using this approach. We report a measurement of neutron backgrounds as found in an off-axis surface location of the Fermilab Booster Neutrino Beam (BNB) target. The results indicate that the Fermilab BNB target is a favorable location for amore » CENNS experiment.« less

  18. Upper Extremity Muscle Volumes and Functional Strength After Resistance Training in Older Adults

    PubMed Central

    Daly, Melissa; Vidt, Meghan E.; Eggebeen, Joel D.; Simpson, W. Greg; Miller, Michael E.; Marsh, Anthony P.; Saul, Katherine R.

    2014-01-01

    Aging leads to a decline in strength and an associated loss of independence. The authors examined changes in muscle volume, maximum isometric joint moment, functional strength, and 1-repetition maximum (1RM) after resistance training (RT) in the upper extremity of older adults. They evaluated isometric joint moment and muscle volume as predictors of functional strength. Sixteen healthy older adults (average age 75 ± 4.3 yr) were randomized to a 6-wk upper extremity RT program or control group. The RT group increased 1RM significantly (p < .01 for all exercises). Compared with controls, randomization to RT led to greater functional pulling strength (p = .003), isometric shoulder-adduction moment (p = .041), elbow-flexor volume (p = .017), and shoulder-adductor volume (p = .009). Shoulder-muscle volumes and isometric moments were good predictors of functional strength. The authors conclude that shoulder strength is an important factor for performing functional reaching and pulling tasks and a key target for upper extremity RT interventions. PMID:22952203

  19. Measurement of total ultrasonic power using thermal expansion and change in buoyancy of an absorbing target

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dubey, P. K., E-mail: premkdubey@gmail.com; Kumar, Yudhisther; Gupta, Reeta

    2014-05-15

    The Radiation Force Balance (RFB) technique is well established and most widely used for the measurement of total ultrasonic power radiated by ultrasonic transducer. The technique is used as a primary standard for calibration of ultrasonic transducers with relatively fair uncertainty in the low power (below 1 W) regime. In this technique, uncertainty comparatively increases in the range of few watts wherein the effects such as thermal heating of the target, cavitations, and acoustic streaming dominate. In addition, error in the measurement of ultrasonic power is also caused due to movement of absorber at relatively high radiated force which occursmore » at high power level. In this article a new technique is proposed which does not measure the balance output during transducer energized state as done in RFB. It utilizes the change in buoyancy of the absorbing target due to local thermal heating. The linear thermal expansion of the target changes the apparent mass in water due to buoyancy change. This forms the basis for the measurement of ultrasonic power particularly in watts range. The proposed method comparatively reduces uncertainty caused by various ultrasonic effects that occur at high power such as overshoot due to momentum of target at higher radiated force. The functionality of the technique has been tested and compared with the existing internationally recommended RFB technique.« less

  20. Measurement of total ultrasonic power using thermal expansion and change in buoyancy of an absorbing target

    NASA Astrophysics Data System (ADS)

    Dubey, P. K.; Kumar, Yudhisther; Gupta, Reeta; Jain, Anshul; Gohiya, Chandrashekhar

    2014-05-01

    The Radiation Force Balance (RFB) technique is well established and most widely used for the measurement of total ultrasonic power radiated by ultrasonic transducer. The technique is used as a primary standard for calibration of ultrasonic transducers with relatively fair uncertainty in the low power (below 1 W) regime. In this technique, uncertainty comparatively increases in the range of few watts wherein the effects such as thermal heating of the target, cavitations, and acoustic streaming dominate. In addition, error in the measurement of ultrasonic power is also caused due to movement of absorber at relatively high radiated force which occurs at high power level. In this article a new technique is proposed which does not measure the balance output during transducer energized state as done in RFB. It utilizes the change in buoyancy of the absorbing target due to local thermal heating. The linear thermal expansion of the target changes the apparent mass in water due to buoyancy change. This forms the basis for the measurement of ultrasonic power particularly in watts range. The proposed method comparatively reduces uncertainty caused by various ultrasonic effects that occur at high power such as overshoot due to momentum of target at higher radiated force. The functionality of the technique has been tested and compared with the existing internationally recommended RFB technique.

  1. A brief review of strength and ballistic assessment methodologies in sport.

    PubMed

    McMaster, Daniel Travis; Gill, Nicholas; Cronin, John; McGuigan, Michael

    2014-05-01

    An athletic profile should encompass the physiological, biomechanical, anthropometric and performance measures pertinent to the athlete's sport and discipline. The measurement systems and procedures used to create these profiles are constantly evolving and becoming more precise and practical. This is a review of strength and ballistic assessment methodologies used in sport, a critique of current maximum strength [one-repetition maximum (1RM) and isometric strength] and ballistic performance (bench throw and jump capabilities) assessments for the purpose of informing practitioners and evolving current assessment methodologies. The reliability of the various maximum strength and ballistic assessment methodologies were reported in the form of intra-class correlation coefficients (ICC) and coefficient of variation (%CV). Mean percent differences (Mdiff = [/Xmethod1 - Xmethod2/ / (Xmethod1 + Xmethod2)] x 100) and effect size (ES = [Xmethod2 - Xmethod1] ÷ SDmethod1) calculations were used to assess the magnitude and spread of methodological differences for a given performance measure of the included studies. Studies were grouped and compared according to their respective performance measure and movement pattern. The various measurement systems (e.g., force plates, position transducers, accelerometers, jump mats, optical motion sensors and jump-and-reach apparatuses) and assessment procedures (i.e., warm-up strategies, loading schemes and rest periods) currently used to assess maximum isometric squat and mid-thigh pull strength (ICC > 0.95; CV < 2.0%), 1RM bench press, back squat and clean strength (ICC > 0.91; CV < 4.3%), and ballistic (vertical jump and bench throw) capabilities (ICC > 0.82; CV < 6.5%) were deemed highly reliable. The measurement systems and assessment procedures employed to assess maximum isometric strength [M(Diff) = 2-71%; effect size (ES) = 0.13-4.37], 1RM strength (M(Diff) = 1-58%; ES = 0.01-5.43), vertical jump capabilities (M(Diff) = 2-57%; ES

  2. Interfacial strength development in thermoplastic resins and fiber-reinforced thermoplastic composites

    NASA Technical Reports Server (NTRS)

    Howes, Jeremy C.; Loos, Alfred C.

    1987-01-01

    An experimental program to develop test methods to be used to characterize interfacial (autohesive) strength development in polysulfone thermoplastic resin and graphite-polysulfone prepreg during processing is reported. Two test methods were used to examine interfacial strength development in neat resin samples. These included an interfacial tension test and a compact tension (CT) fracture toughness test. The interfacial tensile test proved to be very difficult to perform with a considerable amount of data scatter. Thus, the interfacial test was discarded in favor of the fracture toughness test. Interfacial strength development was observed by measuring the refracture toughness of precracked compact tension specimens that were rehealed at a given temperature and contact time. The measured refracture toughness was correlated with temperature and contact time. Interfacial strength development in graphite-polysulfone unidirectional composites was measured using a double cantilever beam (DCB) interlaminar fracture toughness test. The critical strain energy release rate of refractured composite specimens was measured as a function of healing temperature and contact time.

  3. Isometric and swallowing tongue strength in healthy adults.

    PubMed

    Todd, J Tee; Lintzenich, Catherine Rees; Butler, Susan G

    2013-10-01

    The tongue contributes to a safe swallow. It facilitates bolus control during mastication, maintains a bolus in the oral cavity to prevent premature entry of the bolus into the hypopharynx, and helps generate pressure in the hypopharynx during swallowing. This study examined isometric tongue strength and tongue pressure measured during swallowing in healthy young and older adults. Prospective group design. One hundred twenty-six healthy individuals who were recruited as part of a larger study on swallowing participated in this study. Participants were divided into three age groups: 20 to 40 years, 41 to 60 years, and ≥61 years. A KayPentax Digital Swallowing Workstation with an air-filled bulb array was placed on the tongue of each participant (anterior to posterior). Participants completed three isometric tongue presses and three swallows. Repeated measures analyses of variance revealed a significant main effect of age (P = .01) and gender by tongue bulb location interaction (P = .02) for isometric tongue strength. That is, older adults had lower isometric tongue strength than young adults, and females had a greater difference between anterior and posterior tongue strength than males. Tongue strength during swallowing yielded significantly greater anterior versus posterior tongue pressure. This study comprises one of the largest in terms of number of healthy participants reported to date and confirms previous findings that isometric tongue strength decreases with age. Furthermore, given young and older adults generate similar swallowing pressures, swallowing is a submaximal strength activity, yet older adults have less functional reserve. 4. Copyright © 2013 The American Laryngological, Rhinological, and Otological Society, Inc.

  4. Implementation of Maturity for Concrete Strength Measurement and Pay : Tech Summary

    DOT National Transportation Integrated Search

    2017-10-01

    Using the maturity to determine concrete strength has been done for more than four decades. The concept was originally conceived in the late 1940s and early 1950s. More and more state and municipal DOTs are implementing its use every year, with some ...

  5. Effects of HF Treatments on Tensile Strength of Hi-Nicalon Fibers

    NASA Technical Reports Server (NTRS)

    Bansal, Narottam P.

    1998-01-01

    Tensile strengths of as-received Hi-Nicalon fibers and those having a dual BN/SiC surface coating, deposited by chemical vapor deposition, have been measured at room temperature. These fibers were also treated with HF for 24 h followed by tensile strength measurements. Strengths of uncoated and BN/SiC coated Hi-Nicalon fibers extracted from celsian matrix composites, by dissolving away the matrix in HF for 24 h, were also determined. The average tensile strength of uncoated Hi-Nicalon was 3.19 +/- 0.73 GPa with a Weibull modulus of 5.41. The Hi-Nicalon/BN/SiC fibers showed an average strength of 3.04 q 0.53 GPa and Weibull modulus of 6.66. After HF treatments, the average strengths of the uncoated and BN/SiC coated Hi-Nicalon fibers were 2.69 +/- 0.67 GPa and 2.80 +/- 0.53 GPa and the Weibull moduli were 4.93 and 5.96, respectively. The BN/SiC coated fibers extracted from the celsian matrix composite exhibited a strength of 2.38 +/- 0.40 GPa and a Weibull modulus of 7.15. The strength of the uncoated Hi-Nicalon fibers in the composite was so severely degraded that they disintegrated into small fragments during extraction with HF. The uncoated fibers probably undergo mechanical surface damage during hot pressing of the composites. Also, the BN layer on the coated fibers acts as a compliant layer which protects the fibers from mechanical damage during composite processing. The elemental composition and thickness of the fiber coatings were deten-nined using scanning Auger analysis. Microstructural analyses of the fibers and the coatings were done by scanning electron microscopy and transmission electron microscopy. Strengths of fibers calculated using average and measured fiber diameters were in good agreement. Thus, the strength of fibers can be evaluated using an average fiber diameter instead of the measured diameter of each filament.

  6. Target characterizations for a 14N(p,γ)15O cross section measurement

    NASA Astrophysics Data System (ADS)

    Gyürky, Gy.; Csik, A.; Mátyus, Zs.; Fülöp, Zs.; Halász, Z.; Kiss, G. G.; Szücs, T.; Wagner, L.

    2018-01-01

    The 14N(p,γ)15O reaction controls the rate of CNO cycle hydrogen burning in various astrophysical sites and it is therefore one of the most important reactions in nuclear astrophysics. An experimental program is in progress to measure the 14N(p,γ)15O cross section in a wide energy range using a novel approach. A crucial quantity for the cross section determination is the number of N atoms in the target. In this paper the results of different experiments used for N target characterization are presented.

  7. Early Postoperative Measures Predict 1- and 2-Year Outcomes After Unilateral Total Knee Arthroplasty: Importance of Contralateral Limb Strength

    PubMed Central

    Snyder-Mackler, Lynn

    2010-01-01

    Background Total knee arthroplasty (TKA) has been shown to be an effective surgical intervention for people with end-stage knee osteoarthritis. However, recovery of function is variable, and not all people have successful outcomes. Objective The aim of this study was to discern which early postoperative functional measures could predict functional ability at 1 year and 2 years after surgery. Design and Methods One hundred fifty-five people who underwent unilateral TKA participated in the prospective longitudinal study. Functional evaluations were performed at the initial outpatient physical therapy appointment and at 1 and 2 years after surgery. Evaluations consisted of measurements of height, weight, quadriceps muscle strength (force-generating capacity), and knee range of motion; the Timed “Up & Go” Test (TUG); the stair-climbing task (SCT); and the Knee Outcome Survey (KOS) questionnaire. The ability to predict 1- and 2-year outcomes on the basis of early postoperative measures was analyzed with a hierarchical regression. Differences in functional scores were evaluated with a repeated-measures analysis of variance. Results The TUG, SCT, and KOS scores at 1 and 2 years showed significant improvements over the scores at the initial evaluation (P<.001). A weaker quadriceps muscle in the limb that did not undergo surgery (“nonoperated limb”) was related to poorer 1- and 2-year outcomes even after the influence of the other early postoperative measures was accounted for in the regression. Older participants with higher body masses also had poorer outcomes at 1 and 2 years. Postoperative measures were better predictors of TUG and SCT times than of KOS scores. Conclusions Rehabilitation regimens after TKA should include exercises to improve the strength of the nonoperated limb as well as to treat the deficits imposed by the surgery. Emphasis on treating age-related impairments and reducing body mass also might improve long-term outcomes. PMID:19959653

  8. Study on strength estimation of soil cement used in the embedded pile method by electrical resistivity measurement

    NASA Astrophysics Data System (ADS)

    Mochida, Y.; Sakurai, Y.; Indra, H.; Karimi, A. L.

    2017-11-01

    Problems caused by poor quality control and quality assurance of the pre-boring embedded pile construction, such as on domestic apartment house is still occurring nowadays. An adequate consideration for invisible risks inside or below the ground is important in pile foundation construction therefore the demand for advanced and reliable quality assurance is increase in the future. In this research, to understand the quality of the construction at early stage, the compressive strength of cement-soil mixture of pile construction after 28 days is estimated using electrical resistivity value of the mixture. More accurate measurement for electrical resistivity value is conducted by inserting the electrodes without using potassium chloride solution as a catalyst. The result showed that there is a certain tendency in the electric resistivity value at the early age regarding to the type of soil (sand, clay) mixed in. The most accurate estimation was achieved from the electric resistivity value at the first day and several days onwards, and from the compressive strength after 3 days.

  9. [Passive ranging of infrared target using oxygen A-band and Elsasser model].

    PubMed

    Li, Jin-Hua; Wang, Zhao-Ba; Wang Zhi

    2014-09-01

    Passive ranging method of short range and single band was developed based on target radiation and attenuation characteristic of oxygen spectrum absorption. The relation between transmittance of oxygen A band and range of measured target was analyzed. Radiation strength distribution of measured target can be obtained according to the distribution law of absorption coefficient with environmental parameters. Passive ranging mathematical model of short ranges was established using Elsasser model with Lorentz line shape based on the computational methods of band average transmittance and high-temperature gas radiation narrowband model. The range of measured object was obtained using transmittance fitting with test data calculation and theoretical model. Besides, ranging precision was corrected considering the influence of oxygen absorption with enviromental parameter. The ranging experiment platform was established. The source was a 10 watt black body, and a grating spectrometer with 17 cm(-1) resolution was used. In order to improve the light receiving efficiency, light input was collected with 23 mm calibre telescope. The test data was processed for different range in 200 m. The results show that the transmittance accuracy was better than 2.18% in short range compared to the test data with predicted value in the same conditions.

  10. Laboratory simulation of tunable diode laser remote measurement of atmospheric gases using topographic targets

    NASA Technical Reports Server (NTRS)

    Webster, C. R.; Grant, W. B.

    1983-01-01

    In order to test the possibility that tunable diode laser (TDL) systems using topographic targets can be applied to the measurement of a variety of gases at concentrations and distances characteristic of industrial gas leaks, a single-ended TDL system was assembled for use with selected topographic targets to detect NO2 at atmospheric pressure and NO2 and NH3 at low pressures. In both cases, the intensity distribution of radiation backscattered from selected targets was found to be heavily weighted to a specular rather than a Lambertian distribution. A sensitivity of 5 ppm-m has been demonstrated for the case of NO2.

  11. Fracture Strength of AlLiB14

    NASA Astrophysics Data System (ADS)

    Wan, L. F.; Beckman, S. P.

    2012-10-01

    The orthorhombic boride crystal family XYB14, where X and Y are metal atoms, plays a critical role in a unique class of superhard compounds, yet there have been no studies aimed at understanding the origin of the mechanical strength of this compound. We present here the results from a comprehensive investigation into the fracture strength of the archetypal AlLiB14 crystal. First principles, ab initio, methods are used to determine the ideal brittle cleavage strength for several high-symmetry orientations. The elastic tensor and the orientation-dependent Young’s modulus are calculated. From these results the lower bound fracture strength of AlLiB14 is predicted to be between 29 and 31 GPa, which is near the measured hardness reported in the literature. These results indicate that the intrinsic strength of AlLiB14 is limited by the interatomic B-B bonds that span between the B layers.

  12. Directed energy deflection laboratory measurements of common space based targets

    NASA Astrophysics Data System (ADS)

    Brashears, Travis; Lubin, Philip; Hughes, Gary B.; Meinhold, Peter; Batliner, Payton; Motta, Caio; Madajian, Jonathan; Mercer, Whitaker; Knowles, Patrick

    2016-09-01

    We report on laboratory studies of the effectiveness of directed energy planetary defense as a part of the DE-STAR (Directed Energy System for Targeting of Asteroids and exploRation) program. DE-STAR and DE-STARLITE are directed energy "stand-off" and "stand-on" programs, respectively. These systems consist of a modular array of kilowatt-class lasers powered by photovoltaics, and are capable of heating a spot on the surface of an asteroid to the point of vaporization. Mass ejection, as a plume of evaporated material, creates a reactionary thrust capable of diverting the asteroid's orbit. In a series of papers, we have developed a theoretical basis and described numerical simulations for determining the thrust produced by material evaporating from the surface of an asteroid. In the DESTAR concept, the asteroid itself is used as the deflection "propellant". This study presents results of experiments designed to measure the thrust created by evaporation from a laser directed energy spot. We constructed a vacuum chamber to simulate space conditions, and installed a torsion balance that holds a common space target sample. The sample is illuminated with a fiber array laser with flux levels up to 60 MW/m2 , which allows us to simulate a mission level flux but on a small scale. We use a separate laser as well as a position sensitive centroid detector to readout the angular motion of the torsion balance and can thus determine the thrust. We compare the measured thrust to the models. Our theoretical models indicate a coupling coefficient well in excess of 100 μN/Woptical, though we assume a more conservative value of 80 μN/Woptical and then degrade this with an optical "encircled energy" efficiency of 0.75 to 60 μN/Woptical in our deflection modeling. Our measurements discussed here yield about 45 μN/Wabsorbed as a reasonable lower limit to the thrust per optical watt absorbed. Results vary depending on the material tested and are limited to measurements of 1 axis, so

  13. Grip strength as a frailty diagnostic component in geriatric inpatients.

    PubMed

    Dudzińska-Griszek, Joanna; Szuster, Karolina; Szewieczek, Jan

    2017-01-01

    Frailty has emerged as a key medical syndrome predictive of comorbidity, disability, institutionalization and death. As a component of the five frailty phenotype diagnostic criteria, patient grip strength deserves attention as a simple and objective measure of the frailty syndrome. The aim of this study was to assess conditions that influence grip strength in geriatric inpatients. The study group consisted of 80 patients aged 78.6±7.0 years [Formula: see text], with 68.8% women, admitted to the Department of Geriatrics. A comprehensive geriatric assessment was complemented with assessment for the frailty phenotype as described by Fried et al for all patients in the study group. Functional assessment included Barthel Index of Activities of Daily Living (Barthel Index), Instrumental Activities of Daily Living Scale and Mini-Mental State Examination. Three or more frailty criteria were positive in 32 patients (40%), while 56 subjects (70%) fulfilled the frailty criterion of weakness (grip strength test). Multivariate linear regression analysis revealed that two independent measures showed positive association with grip strength - Mini-Mental State Examination score (β=0.239; P =0.001) and statin use (β=0.213; P =0.002) - and four independent measures were negatively associated with grip strength - female sex (β=-0.671; P <0.001), C-reactive protein (β=-0.253; P <0.001), prior myocardial infarction (β=-0.190; P =0.006) and use of an antidepressant (β=-0.163; P =0.018). Low physical activity was identified as the only independent qualitative frailty component associated with 2-year mortality in multivariate logistic regression analysis after adjustment for age and sex (odds ratio =6.000; 95% CI =1.357-26.536; P =0.018). Cognitive function, somatic comorbidity and medical treatment affect grip strength as a measure of physical frailty in geriatric inpatients. Grip strength was not predictive of 2-year mortality in this group.

  14. Quantitative muscle ultrasound and quadriceps strength in patients with post-polio syndrome.

    PubMed

    Bickerstaffe, Alice; Beelen, Anita; Zwarts, Machiel J; Nollet, Frans; van Dijk, Johannes P

    2015-01-01

    We investigated whether muscle ultrasound can distinguish muscles affected by post-polio syndrome (PPS) from healthy muscles and whether severity of ultrasound abnormalities is associated with muscle strength. Echo intensity, muscle thickness, and isometric strength of the quadriceps muscles were measured in 48 patients with PPS and 12 healthy controls. Patients with PPS had significantly higher echo intensity and lower muscle thickness than healthy controls. In patients, both echo intensity and muscle thickness were associated independently with muscle strength. A combined measure of echo intensity and muscle thickness was more strongly related to muscle strength than either parameter alone. Quantitative ultrasound distinguishes healthy muscles from those affected by PPS, and measures of muscle quality and quantity are associated with muscle strength. Hence, ultrasound could be a useful tool for assessing disease severity and monitoring changes resulting from disease progression or clinical intervention in patients with PPS. © 2014 Wiley Periodicals, Inc.

  15. Relationship between the tensile strengths and diameters of human umbilical cords.

    PubMed

    Fernando, D M G; Gamage, S M K; Ranmohottige, S; Weerakkody, I; Abeyruwan, H; Parakrama, H

    2018-05-01

    Mothers of alleged infanticides might claim that umbilical cord broke during precipitate delivery causing injuries detected on baby at autopsy. There is paucity of evidence regarding this possibility. The objective of the study was to determine relationship between tensile strength and diameter or weight per unit length of cord. Diameters and weights per unit length of fresh umbilical cords were determined. Tensile strengths were measured by Hounsfield Testing Machine. Relationship between tensile strength versus cord diameter and weight per unit length were analyzed. Of 122 cords, average tensile strength, diameter and weight per centimeter were 50.4 N, 7.73 mm and 6.87 g respectively. The tensile strengths were directly proportional to diameter. There was no association between tensile strength and weight per centimeter. Measurement of the diameter of cord is important during autopsy to predict tensile strength and thereby to presume whether cord could have broken by the weight of the baby. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  16. Back muscle strength, lifting, and stooped working postures.

    PubMed

    Poulsen, E; Jørgensen, K

    1971-09-01

    When lifting loads and working in a forward stooped position, the muscles of the back rather than the ligaments and bony structures of the spine should overcome the gravitational forces. Formulae, based on measurements of back muscle strength, for prediction of maximal loads to be lifted, and for the ability to sustain work in a stooped position, have been worked out and tested in practical situations. From tests with 50 male and female subjects the simplest prediction formulae for maximum loads were: max. load = 1.10 x isometric back muscle strength for men; and max. load = 0.95 x isometric back muscle strength - 8 kg for women. Some standard values for maximum lifts and permissible single and repeated lifts have been calculated for men and women separately and are given in Table 1. From tests with 65 rehabilitees it was found that the maximum isometric strength of the back muscles measured at shoulder height should exceed 2/3 of the body weight, if fatigue and/or pain in the back muscles is to be avoided during work in a standing stooped position.

  17. Determining Source Strength of Semivolatile Organic Compounds using Measured Concentrations in Indoor Dust

    PubMed Central

    Shin, Hyeong-Moo; McKone, Thomas E.; Nishioka, Marcia G.; Fallin, M. Daniele; Croen, Lisa A.; Hertz-Picciotto, Irva; Newschaffer, Craig J.; Bennett, Deborah H.

    2014-01-01

    Consumer products and building materials emit a number of semivolatile organic compounds (SVOCs) in the indoor environment. Because indoor SVOCs accumulate in dust, we explore the use of dust to determine source strength and report here on analysis of dust samples collected in 30 U.S. homes for six phthalates, four personal care product ingredients, and five flame retardants. We then use a fugacity-based indoor mass-balance model to estimate the whole house emission rates of SVOCs that would account for the measured dust concentrations. Di-2-ethylhexyl phthalate (DEHP) and di-iso-nonyl phthalate (DiNP) were the most abundant compounds in these dust samples. On the other hand, the estimated emission rate of diethyl phthalate (DEP) is the largest among phthalates, although its dust concentration is over two orders of magnitude smaller than DEHP and DiNP. The magnitude of the estimated emission rate that corresponds to the measured dust concentration is found to be inversely correlated with the vapor pressure of the compound, indicating that dust concentrations alone cannot be used to determine which compounds have the greatest emission rates. The combined dust-assay modeling approach shows promise for estimating indoor emission rates for SVOCs. PMID:24118221

  18. Analysis of the effect on optical equipment caused by solar position in target flight measure

    NASA Astrophysics Data System (ADS)

    Zhu, Shun-hua; Hu, Hai-bin

    2012-11-01

    Optical equipment is widely used to measure flight parameters in target flight performance test, but the equipment is sensitive to the sun's rays. In order to avoid the disadvantage of sun's rays directly shines to the optical equipment camera lens when measuring target flight parameters, the angle between observation direction and the line which connects optical equipment camera lens and the sun should be kept at a big range, The calculation method of the solar azimuth and altitude to the optical equipment at any time and at any place on the earth, the equipment observation direction model and the calculating model of angle between observation direction and the line which connects optical equipment camera lens are introduced in this article. Also, the simulation of the effect on optical equipment caused by solar position at different time, different date, different month and different target flight direction is given in this article.

  19. Ego strengths, racial/ethnic identity, and well-being among North American Indian/First Nations adolescents.

    PubMed

    Gfellner, Barbara

    2016-01-01

    This study investigated associations between ego strengths (psychosocial development), racial/ethnic identity using Multi-Ethnic Identity Measure-Revised (exploration, commitment) and Multidimensional Measure of Racial Identity (centrality, private regard, public regard) dimensions, and personal adjustment/well-being among 178 North American Indian/First Nations adolescents who resided and attended school on reserves. As predicted, ego strengths related directly with centrality, private regard, and the adjustment measures; the moderation of ego strengths for exploration, commitment, and private regard reflected adverse functioning for those with less than advanced ego strengths. As well, ego strengths mediated associations between centrality and private regard with several measures of personal well-being. Practical and theoretical implications are considered.

  20. Quantitative Targeted Proteomics and Electrochromic Shift for Measuring Photosystem Content of Marine Phytoplankton

    NASA Astrophysics Data System (ADS)

    Brown, C. M.; Bailleul, B.; Melanson, J. R.; Campbell, D. A.; Cockshutt, A. M.; Cardol, P.

    2016-02-01

    Abundance and stoichiometry data for the photosystems, the intersystem electron transport complexes and the Calvin cycle enzymes are rich in information about light and nutrient acclimation. Quantifying these complexes is essential for understanding limitations on and capacities for photosynthesis. Targeted quantitative immunodetections of conserved subunits (eg. PsbA for PSII; PsaC for PSI) are becoming an established method for absolute measurement of these complexes. An advantage of protein measurements is that they can be done with non-living flash-frozen samples and processed post-field. A pitfall of physical versus functional measures is that in some scenarios, such as during photoinhibition of photosystem II (PSII), physical and functional measures give different values, but such disparities are often meaningful, informing targeted studies of regulation, repair and enzyme kinetics. Electrochromic Shift (ECS) is an alternative, fast and noninvasive method which can be exploited to determine functional PSI:PSII ratios in living cells. The basis for ECS is that pigments in the photosynthetic membrane exhibit a shift in their absorption spectra when the electric component of the proton motive force is generated across the membrane in the light. Cross-validation of methods by independent measures builds confidence in results from both approaches and can be useful for ground truthing of underway or high-throughput optical measurements or functional measurements from bioassays. We present comparative data from immunoquantitation and ECS for an array of diatom taxa. The physical data fall within established ranges. The basis for similarities and disparities in the photosystem stoichiometries between the methods are discussed.